Science.gov

Sample records for affinity chromatography column

  1. Twin-column CaptureSMB: a novel cyclic process for protein A affinity chromatography.

    PubMed

    Angarita, Monica; Müller-Späth, Thomas; Baur, Daniel; Lievrouw, Roel; Lissens, Geert; Morbidelli, Massimo

    2015-04-10

    A twin-column counter-current chromatography processes, CaptureSMB, was used for the protein A affinity capture of a monoclonal antibody (mAb). By means of sequential loading, the process improves the utilization of the stationary phase by achieving loadings much closer to the static binding capacity of the resin in comparison to batch chromatography. Using a mAb capture case study with protein A affinity chromatography, the performance and product quality obtained from CaptureSMB and batch processes were compared. The effect of the flow rate, column length and titer concentration on the process performance and product quality were evaluated. CaptureSMB showed superior performance compared to batch chromatography with respect to productivity, capacity utilization, product concentration and buffer consumption. A simplified economic evaluation showed that CaptureSMB could decrease resin costs of 10-30% depending on the manufacturing scenario.

  2. Isolation and purification of blood group antigens using immuno-affinity chromatography on short monolithic columns.

    PubMed

    Mönster, Andrea; Hiller, Oliver; Grüger, Daniela; Blasczyk, Rainer; Kasper, Cornelia

    2011-02-04

    Monolithic columns have gained increasing attention as stationary phases for the separation of biomolecules and biopharmaceuticals. In the present work the performance of monolithic convective interaction media (CIM(®)) chromatography for the purification of blood group antigens was established. The proteins employed in this study are derived from blood group antigens Knops, JMH and Scianna, equipped both with a His-tag and with a V5-tag by which they can be purified. In a first step a monoclonal antibody directed against the V5-tag was immobilized on a CIM(®) Disk with epoxy chemistry. After this, the immobilized CIM(®) Disk was used in immuno-affinity chromatography to purify the three blood group antigens from cell culture supernatant. Up-scaling of the applied technology was carried out using CIM(®) Tubes. In comparison to conventional affinity chromatography, blood group antigens were also purified via His-tag using a HiTrap(®) metal-affinity column. The two purifications have been compared regarding purity, yield and purification speed. Using the monolithic support, it was possible to isolate the blood group antigens with a higher flow rate than using the conventional bed-packed column.

  3. In-column ATR-FTIR spectroscopy to monitor affinity chromatography purification of monoclonal antibodies

    PubMed Central

    Boulet-Audet, Maxime; Kazarian, Sergei G.; Byrne, Bernadette

    2016-01-01

    In recent years many monoclonal antibodies (mAb) have entered the biotherapeutics market, offering new treatments for chronic and life-threatening diseases. Protein A resin captures monoclonal antibody (mAb) effectively, but the binding capacity decays over repeated purification cycles. On an industrial scale, replacing fouled Protein A affinity chromatography resin accounts for a large proportion of the raw material cost. Cleaning-in-place (CIP) procedures were developed to extend Protein A resin lifespan, but chromatograms cannot reliably quantify any remaining contaminants over repeated cycles. To study resin fouling in situ, we coupled affinity chromatography and Fourier transform infrared (FTIR) spectroscopy for the first time, by embedding an attenuated total reflection (ATR) sensor inside a micro-scale column while measuring the UV 280 nm and conductivity. Our approach quantified the in-column protein concentration in the resin bed and determined protein conformation. Our results show that Protein A ligand leached during CIP. We also found that host cell proteins bound to the Protein A resin even more strongly than mAbs and that typical CIP conditions do not remove all fouling contaminants. The insights derived from in-column ATR-FTIR spectroscopic monitoring could contribute to mAb purification quality assurance as well as guide the development of more effective CIP conditions to optimise resin lifespan. PMID:27470880

  4. In-column ATR-FTIR spectroscopy to monitor affinity chromatography purification of monoclonal antibodies

    NASA Astrophysics Data System (ADS)

    Boulet-Audet, Maxime; Kazarian, Sergei G.; Byrne, Bernadette

    2016-07-01

    In recent years many monoclonal antibodies (mAb) have entered the biotherapeutics market, offering new treatments for chronic and life-threatening diseases. Protein A resin captures monoclonal antibody (mAb) effectively, but the binding capacity decays over repeated purification cycles. On an industrial scale, replacing fouled Protein A affinity chromatography resin accounts for a large proportion of the raw material cost. Cleaning-in-place (CIP) procedures were developed to extend Protein A resin lifespan, but chromatograms cannot reliably quantify any remaining contaminants over repeated cycles. To study resin fouling in situ, we coupled affinity chromatography and Fourier transform infrared (FTIR) spectroscopy for the first time, by embedding an attenuated total reflection (ATR) sensor inside a micro-scale column while measuring the UV 280 nm and conductivity. Our approach quantified the in-column protein concentration in the resin bed and determined protein conformation. Our results show that Protein A ligand leached during CIP. We also found that host cell proteins bound to the Protein A resin even more strongly than mAbs and that typical CIP conditions do not remove all fouling contaminants. The insights derived from in-column ATR-FTIR spectroscopic monitoring could contribute to mAb purification quality assurance as well as guide the development of more effective CIP conditions to optimise resin lifespan.

  5. Selective isolation of β-glucan from corn pericarp hemicelluloses by affinity chromatography on cellulose column.

    PubMed

    Yoshida, Tomoki; Honda, Yoichi; Tsujimoto, Takashi; Uyama, Hiroshi; Azuma, Jun-ichi

    2014-10-13

    A combination of anion-exchange chromatography and affinity chromatography on a cellulose column was found to be effective for the isolation of β-(1,3;1,4)-glucan (BG) from corn pericarp hemicelluloses (CPHs). CPHs containing 6.6% BG were extracted from corn pericarp with 6M urea-2 wt% NaOH solution and initially fractionated into neutral and acidic parts by anion exchange chromatography to remove acidic arabinoxylan consisting of arabinose (35.6%) and xylose (50.9%). The neutral fraction (yield; 10.1% on the basis of CPHs) consisting of 1.0% arabinose, 10.1% xylose and 80.3% glucose containing 28.4% BG was then applied to a cellulose column of Whatman CF-11. BG could be recovered from the adsorbed fraction on the cellulose column by elution with 2% NaOH in a yield of 2.6% on the basis of CPHs with a purity of 84.7%. The chemical structure of the isolated corn pericarp BG was confirmed by (13)C NMR spectroscopic, methylation and lichenase treatment analyses. The results indicate that the ratios of (1,4)/(1,3) linkage and cellotriosyl/cellotetraosyl segments of the BG were 2.60 and 2.5, respectively.

  6. The development of mitochondrial membrane affinity chromatography columns for the study of mitochondrial transmembrane proteins

    PubMed Central

    Habicht, K-L.; Singh, N.S.; Indig, F.E.; Wainer, I.W.; Moaddel, R.; Shimmo, R.

    2015-01-01

    Mitochondrial membrane fragments from U-87 MG (U87MG) and HEK-293 cells were successfully immobilized on to Immobilized Artificial Membrane (IAM) chromatographic support and surface of activated open tubular (OT) silica capillary resulting in mitochondrial membrane affinity chromatography (MMAC) columns. Translocator protein (TSPO), located in mitochondrial outer membrane as well as sulfonylurea and mitochondrial permeability transition pore (mPTP) receptors, localized to the inner membrane, were characterized. Frontal displacement experiments with multiple concentrations of dipyridamole (DIPY) and PK-11195 were run on MMAC-(U87MG) column and the binding affinities (Kd) determined were 1.08 ± 1.49 and 0.0086 ± 0.0006 μM respectively, which was consistent with previously reported values. Further, binding affinities (Ki) for DIPY binding site were determined for TSPO ligands, PK-11195, mesoporphyrin IX, protoporphyrin IX and rotenone. Additionally, the relative ranking of these TSPO ligands based on single displacement studies using DIPY as marker on MMAC-(U87MG) was consistent with the obtained Ki values. The immobilization of mitochondrial membrane fragments was also confirmed by confocal microscopy. PMID:26049098

  7. The Binding of Biotin to Sepharose-Avidin Column: Demonstration of the Affinity Chromatography Technique

    ERIC Educational Resources Information Center

    Landman, A. D.; Landman, N. N.

    1976-01-01

    Describes a biochemistry experiment that illustrates the methodology of affinity chromatography by attaching avidin, a glycoprotein in egg white, to a Sepharose matrix in order to bind biotin-containing proteins. (MLH)

  8. Induced binding of proteins by ammonium sulfate in affinity and ion-exchange column chromatography.

    PubMed

    Arakawa, Tsutomu; Tsumoto, Kouhei; Ejima, Daisuke; Kita, Yoshiko; Yonezawa, Yasushi; Tokunaga, Masao

    2007-04-10

    In general, proteins bind to affinity or ion-exchange columns at low salt concentrations, and the bound proteins are eluted by raising the salt concentration, changing the solvent pH, or adding competing ligands. Blue-Sepharose is often used to remove bovine serum albumin (BSA) from samples, but when we applied BSA to Blue-Sepharose in 20 mM phosphate, pH 7.0, 50%-60% of the protein flowed through the column; however, complete binding of BSA was achieved by the addition of 2 M ammonium sulfate (AS) to the column equilibration buffer and the sample. The bound protein was eluted by decreasing the AS concentration or by adding 1 M NaCl or arginine. AS at high concentrations resulted in binding of BSA even to an ion-exchange column, Q-Sepharose, at pH 7.0. Thus, although moderate salt concentrations elute proteins from Blue-Sepharose or ion-exchange columns, proteins can be bound to these columns under extreme salting-out conditions. Similar enhanced binding of proteins by AS was observed with an ATP-affinity column.

  9. Sequential injection affinity chromatography utilizing an albumin immobilized monolithic column to study drug-protein interactions.

    PubMed

    Zacharis, Constantinos K; Kalaitzantonakis, Eftichios A; Podgornik, Ales; Theodoridis, Georgios

    2007-03-09

    In this study, sequential injection affinity chromatography was used for drug-protein interactions studies. The analytical system used consisted of a sequential injection analysis (SIA) manifold directly connected with convective interaction media (CIM) monolithic epoxy disks modified by ligand-immobilization of protein. A non-steroidal, anti-inflammatory drug, naproxen (NAP) and bovine serum albumin (BSA) were selected as model drug and protein, respectively. The SIA system was used for sampling, introduction and propulsion of drug towards to the monolithic column. Association equilibrium constants, binding capacity at various temperatures and thermodynamic parameters (free energy DeltaG, enthalpy DeltaH) of the binding reaction of naproxen are calculated by using frontal analysis mathematics. The variation of incubation time and its effect in on-line binding mode was also studied. The results indicated that naproxen had an association equilibrium constant of 2.90 x 10(6)M(-1) at pH 7.4 and 39 degrees C for a single binding site. The associated change in enthalpy (DeltaH) was -27.36 kcal mol(-1) and the change in entropy (DeltaS) was -73 cal mol(-1)K(-1) for a single type of binding sites. The location of the binding region was examined by competitive binding experiments using a biphosphonate drug, alendronate (ALD), as a competitor agent. It was found that the two drugs occupy the same class of binding sites on BSA. All measurements were performed with fluorescence (lambda(ext)=230 nm, lambda(em)=350 nm) and spectrophotometric detection (lambda=280 nm).

  10. Affinity-based screening of combinatorial libraries using automated, serial-column chromatography

    SciTech Connect

    Evans, D.M.; Williams, K.P.; McGuinness, B.

    1996-04-01

    The authors have developed an automated serial chromatographic technique for screening a library of compounds based upon their relative affinity for a target molecule. A {open_quotes}target{close_quotes} column containing the immobilized target molecule is set in tandem with a reversed-phase column. A combinatorial peptide library is injected onto the target column. The target-bound peptides are eluted from the first column and transferred automatically to the reversed-phase column. The target-specific peptide peaks from the reversed-phase column are identified and sequenced. Using a monoclonal antibody (3E-7) against {beta}-endorphin as a target, we selected a single peptide with sequence YGGFL from approximately 5800 peptides present in a combinatorial library. We demonstrated the applicability of the technology towards selection of peptides with predetermined affinity for bacterial lipopolysaccharide (LPS, endotoxin). We expect that this technology will have broad applications for high throughput screening of chemical libraries or natural product extracts. 21 refs., 4 figs.

  11. Isolation of human beta-interferon receptor by wheat germ lectin affinity and immunosorbent column chromatographies

    SciTech Connect

    Zhang, Z.Q.; Fournier, A.; Tan, Y.H.

    1986-06-15

    Radioiodinated human beta-interferon-Ser 17 (Betaseron) was reversibly cross-linked to Daudi cells by dithiobis(succinimidylpropionate). The radioactive ligand was cross-linked to three macromolecules forming labeled complexes of apparent Mr values of 130,000, 220,000, and 320,000. Betaseron, human alpha-interferon, human interleukin 2 but not recombinant human gamma-interferon competed with the labeled ligand for binding to these putative receptor(s). Human leukocyte-produced gamma-interferon competed weakly with /sup 125/I-Betaseron for binding to Daudi cells. The Betaseron-receptor complex(es) was purified by passage through a wheat germ lectin column followed by chromatography on an anti-interferon immunosorbent column and semipreparative gel electrophoresis. The cross-linked ligand-receptor complex was shown to be highly purified by sodium dodecyl sulfate and acetic acid:urea:Triton X-100 polyacrylamide gel electrophoresis. It can be dissociated into the labeled Betaseron (Mr = 17,000) ligand and a receptor moiety which has an apparent molecular weight of 110,000. The chromatographic behavior of the ligand-receptor complex on wheat germ lectin column suggests that the receptor is a glycoprotein. The described procedure yielded about 1 microgram of Betaseron receptor from 10(10) Daudi cells, estimated to contain a maximum of about 15 micrograms of the receptor.

  12. Characterization of a multiple endogenously expressed adenosine triphosphate-binding cassette transporters using nuclear and cellular membrane affinity chromatography columns.

    PubMed

    Habicht, K-L; Singh, N S; Khadeer, M A; Shimmo, R; Wainer, I W; Moaddel, R

    2014-04-25

    Glioblastoma multiforme is an aggressive form of human astrocytoma, with poor prognosis due to multi-drug resistance to a number of anticancer drugs. The observed multi-drug resistance is primarily due to the efflux activity of ATP-Binding Cassette (ABC) efflux transporters such as Pgp, MRP1 and BCRP. The expression of these transporters has been demonstrated in nuclear and cellular membranes of the LN-229 human glioblastoma cell line. Nuclear membrane and cellular membrane fragments from LN-229 cells were immobilized on the IAM stationary phase to create nuclear and cellular membrane affinity chromatography columns, (NMAC(LN-229)) and (CMAC(LN-229)), respectively. Pgp, MRP1 and BCRP transporters co-immobilized on both columns were characterized and compared by establishing the binding affinities for estrone-3-sulfate (3.8 vs. 3.7μM), verapamil (0.6 vs. 0.7μM) and prazosin (0.099 vs. 0.033μM) on each column and no significant differences were observed. Since the marker ligands had overlapping selectivities, the selective characterization of each transporter was carried out by saturation of the binding sites of the non-targeted transporters. The addition of verapamil (Pgp and MRP1 substrate) to the mobile phase allowed the comparative screening of eight compounds at the nuclear and cellular BCRP using etoposide as the marker ligand. AZT increased the retention of etoposide (+15%), a positive allosteric interaction, on the CMAC(LN-229) column and decreased it (-5%) on the NMAC(LN-229), while the opposite effect was produced by rhodamine. The results indicate that there are differences between the cellular and nuclear membrane expressed BCRP and that NMAC and CMAC columns can be used to probe these differences.

  13. Chromatography on DEAE ion-exchange and Protein G affinity columns in tandem for the separation and purification of proteins.

    PubMed

    Qi, Y; Yan, Z; Huang, J

    2001-10-30

    A high-performance liquid-chromatographic method based on coupled DEAE anion-exchange and Protein G affinity columns has been developed for the simultaneous separation and purification of immunoglobulin G and albumin from mouse serum. The diluted mouse serum was injected directly into this system, and the proteins were eluted separately from the DEAE and Protein G columns, coupled in series, by the column-switching technique. The advantages of this method are that IgG and albumin can be separated and purified simultaneously, the expensive affinity column is protected from contamination by the impurities in the mouse serum, and it is fast, selective, robust, and reproducible.

  14. Column Liquid Chromatography.

    ERIC Educational Resources Information Center

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  15. Purification of GFP fusion proteins with high purity and yield by monoclonal antibody-coupled affinity column chromatography.

    PubMed

    Zhuang, Ran; Zhang, Yuan; Zhang, Rui; Song, Chaojun; Yang, Kun; Yang, Angang; Jin, Boquan

    2008-05-01

    GFP has often been used as a marker of gene expression, protein localization in living and fixed tissues as well as for protein targeting in intact cells and organisms. Monitoring foreign protein expression via GFP fusion is also very appealing for bioprocess applications. Many cells, including bacterial, fungal, plant, insect and mammalian cells, can express recombinant GFP (rGFP) efficiently. Several methods and procedures have been developed to purify the rGFP or recombinant proteins fused with GFP tag. However, most current GFP purification methods are limited by poor yields and low purity. In the current study, we developed an improved purification method, utilizing a FMU-GFP.5 monoclonal antibody (mAb) to GFP together with a mAb-coupled affinity chromatography column. The method resulted in a sample that was highly pure (more than 97% homogeneity) and had a sample yield of about 90%. Moreover, the GFP epitope permitted the isolation of almost all the active recombinant target proteins fused with GFP, directly and easily, from the crude cellular sources. Our data suggests this method is more efficient than any currently available method for purification of GFP protein.

  16. Effect of the detergent Tween-20 on the DNA affinity chromatography of Gal4, C/EBPalpha, and lac repressor with observations on column regeneration.

    PubMed

    Robinson, F Darlene; Moxley, Robert A; Jarrett, Harry W

    2004-01-23

    C/EBPalpha, Gal4, and lac repressor, representing three different transcription factor homology families, were expressed as fusion proteins and used to characterize the effects of column aging, Mg2+, the nonionic detergent Tween-20, column loading, and bovine serum albumin on DNA-affinity chromatography. When lac-repressor-beta-galactosidase fusion protein is loaded onto a new DNA-Sepharose column, less elutes from a new column than one that has been used two or more times. Higher amounts of lac repressor, the Green Fluorescent Protein fusions with CAAT enhancer binding protein (C/EBPalpha) and Gal4, elute from the columns when 0.1% Tween-20 is added to the mobile phase. The amount of improvement found depends upon the transcription factor studied and the amount of the protein loaded on the column; lac repressor and Gal4 are eluted in higher amounts over a large range of protein loads while C/EBP shows the greatest effect at low protein loads. This detergent effect is seen when either Sepharose or silica is used for the stationary phase. Including bovine serum albumin in the mobile phase gives a similar though lesser improvement to that observed with Tween-20. Mg2+ or EDTA in the mobile phase gave similar chromatography for C/EBP; since EDTA protects columns from DNases, its inclusion in the mobile phase is preferred. After extended use, the DNA affinity columns no longer bind transcription factors and this is not due to losses of DNA from the columns. Two simple methods (sodium dodecylsulfate and KSCN) were developed to regenerate such worn out columns.

  17. Online micro-solid-phase extraction based on boronate affinity monolithic column coupled with high-performance liquid chromatography for the determination of monoamine neurotransmitters in human urine.

    PubMed

    Yang, Xiaoting; Hu, Yufei; Li, Gongke

    2014-05-16

    Quantification of monoamine neurotransmitters is very important in diagnosing and monitoring of patients with neurological disorders. We developed an online analytical method to selectively determine urinary monoamine neurotransmitters, which coupled the boronate affinity monolithic column micro-solid-phase extraction with high-performance liquid chromatography (HPLC). The boronate affinity monolithic column was prepared by in situ polymerization of vinylphenylboronic acid (VPBA) and N,N'-methylenebisacrylamide (MBAA) in a stainless capillary column. The prepared monolithic column showed good permeability, high extraction selectivity and capacity. The column-to-column reproducibility was satisfactory and the enrichment factors were 17-243 for four monoamine neurotransmitters. Parameters that influence the online extraction efficiency, including pH of sample solution, flow rate of extraction and desorption, extraction volume and desorption volume were investigated. Under the optimized conditions, the developed method exhibited low limit of detection (0.06-0.80μg/L), good linearity (with R(2) between 0.9979 and 0.9993). The recoveries in urine samples were 81.0-105.5% for four monoamine neurotransmitters with intra- and inter-day RSDs of 2.1-8.2% and 3.7-10.6%, respectively. The online analytical method was sensitive, accurate, selective, reliable and applicable to analysis of trace monoamine neurotransmitters in human urine sample.

  18. On-column entrapment of alpha1-acid glycoprotein for studies of drug-protein binding by high-performance affinity chromatography.

    PubMed

    Anguizola, Jeanethe; Bi, Cong; Koke, Michelle; Jackson, Abby; Hage, David S

    2016-08-01

    An on-column approach for protein entrapment was developed to immobilize alpha1-acid glycoprotein (AGP) for drug-protein binding studies based on high-performance affinity chromatography. Soluble AGP was physically entrapped by using microcolumns that contained hydrazide-activated porous silica and by employing mildly oxidized glycogen as a capping agent. Three on-column entrapment methods were evaluated and compared to a previous slurry-based entrapment method. The final selected method was used to prepare 1.0 cm × 2.1 mm I.D. affinity microcolumns that contained up to 21 (±4) μg AGP and that could be used over the course of more than 150 sample applications. Frontal analysis and zonal elution studies were performed on these affinity microcolumns to examine the binding of various drugs with the entrapped AGP. Site-selective competition studies were also conducted for these drugs. The results showed good agreement with previous observations for these drug-protein systems and with binding constants that have been reported in the literature. The entrapment method developed in this study should be useful for future work in the area of personalized medicine and in the high-throughput screening of drug interactions with AGP or other proteins. Graphical abstract On-column protein entrapment using a hydrazide-activated support and oxidized glycogen as a capping agent.

  19. An Undergraduate Column Chromatography Experiment.

    ERIC Educational Resources Information Center

    Danot, M.; And Others

    1984-01-01

    Background information, list of materials needed, and procedures used are provided for an experiment designed to introduce undergraduate students to the theoretical and technical aspects of column chromatography. The experiment can also be shortened to serve as a demonstration of the column chromatography technique. (JN)

  20. Development and characterization of the α3β4α5 nicotinic receptor cellular membrane affinity chromatography column and its application for on line screening of plant extracts

    PubMed Central

    Ciesla, L.; Okine, M.; Rosenberg, A.; Dossou, K.S.S.; Toll, L.; Wainer, I.W.; Moaddel, R.

    2016-01-01

    The α3β4α5 nAChR has been recently shown to be a useful target for smoking cessation pharmacotherapies. Herein, we report on the development and characterization of the α3β4α5 nicotinic receptor column by frontal displacement chromatography. The binding affinity of the nicotine and minor alkaloids found in tobacco smoke condensates were determined for both the α3β4 and α3β4α5 nicotinic receptors. It was demonstrated that while no subtype selectivity was observed for nicotine and nornicotine, anabasine was selective for the α3β4α5 nicotinic receptor. The non-competitive inhibitor binding site was also studied and it was demonstrated while mecamylamine was not selective between subtypes, buproprion showed subtype selectivity for the α3β4 nicotinic receptor. The application of this methodology to complex mixtures was then carried out by screening aqueous-alcoholic solutions of targeted plant extracts, including Lycopodium clavatum L. (Lycopodiaceae) and Trigonella foenum graecum L. (Fabaceae) against both the α3β4 and α3β4α5 nAChRs. PMID:26774122

  1. The synthesis and characterization of cellular membrane affinity chromatography columns for the study of human multidrug resistant proteins MRP1, MRP2 and human breast cancer resistant protein BCRP using membranes obtained from Spodoptera frugiperda (Sf9) insect cells.

    PubMed

    Bhatia, Prateek A; Moaddel, Ruin; Wainer, Irving W

    2010-06-15

    CMAC (cellular membrane affinity chromatography columns) have been developed for the study of the human multidrug transporters MRP1, MRP2 and the breast cancer resistance protein (BCRP). The columns were constructed using the immobilized artificial membrane (IAM) stationary phase and cellular membrane fragments obtained from Spodoptera frugiperda (Sf9) cells that had been stably transfected with human Mrp1, Mrp2 or Bcrp cDNA, using a baculovirus expression system. The resulting CMAC(Sf9(MRP1)), CMAC(Sf9(MRP2)) and CMAC(Sf9(BCRP)) columns and a control column produced using membrane fragments from non-transfected Sf9 cells, CMAC(Sf9), were characterized using frontal affinity chromatography using [(3)H]-etoposide as the marker ligand and etoposide, benzbromarone and MK571 as the displacers on the CMAC(Sf9(MRP1)) column, etoposide and furosemide on the CMAC(Sf9(MRP2)) column and etoposide and fumitremorgin C on the CMAC(Sf9(BCPR)) column. The binding affinities (K(i) values) obtained from the chromatographic studies were consistent with the data obtained using non-chromatographic techniques and the results indicate that the immobilized MRP1, MRP2 and BCRP transporters retained their ability to selectively bind known ligands. (S)-verapamil displaced [(3)H]-etoposide on the CMAC(Sf9(MRP1)) column to a greater extent than (R)-verapamil and the relative IC(50) values of the enantiomers were calculated using the changes in the retention times of the marker. The observed enantioselectivity and calculated IC(50) values were consistent with previously reported data. The results indicated that the CMAC(Sf9(MRP1)), CMAC(Sf9(MRP2)) and CMAC(Sf9(BCRP)) columns can be used for the study of binding to the MRP1, MRP2 and BCRP transporters and that membranes from the Sf9 cell line can be used to prepare CMAC columns. This is the first example of the use of membranes from a non-mammalian cell line in an affinity chromatographic system.

  2. The synthesis and characterization of a nuclear membrane affinity chromatography column for the study of human breast cancer resistant protein (BCRP) using nuclear membranes obtained from the LN-229 cells.

    PubMed

    Habicht, K-L; Frazier, C; Singh, N; Shimmo, R; Wainer, I W; Moaddel, R

    2013-01-01

    BCRP expression has been reported in glioblastoma cell lines and clinical specimens and has been shown to be expressed both in purified nuclei and in the soluble cytoplasmic fraction. To date, the nuclear BCRP has not been characterized. Our laboratory has previously developed an online chromatographic approach for the study of binding interactions between ligands and protein, cellular membrane affinity chromatography. To this end, we have immobilized the nuclear membrane fragments onto an immobilized artificial membrane stationary phase (IAM), resulting in the nuclear membrane affinity chromatography (NMAC) column. Initial characterization was carried out on the radio flow detector, as well as the LC-MSD, using frontal displacement chromatography techniques. Etoposide, a substrate for BCRP, was initially tested, to determine the functional immobilization of BCRP. Frontal displacement experiments with multiple concentrations of etoposide were run and the binding affinity was determined to be 4.54 μM, which is in close agreement with literature. The BCRP was fully characterized on the NMAC column and this demonstrates that for the first time the nuclear membranes have been successfully immobilized.

  3. Self-regenerating column chromatography

    DOEpatents

    Park, W.K.

    1995-05-30

    The present invention provides a process for treating both cations and anions by using a self-regenerating, multi-ionic exchange resin column system which requires no separate regeneration steps. The process involves alternating ion-exchange chromatography for cations and anions in a multi-ionic exchange column packed with a mixture of cation and anion exchange resins. The multi-ionic mixed-charge resin column works as a multi-function column, capable of independently processing either cationic or anionic exchange, or simultaneously processing both cationic and anionic exchanges. The major advantage offered by the alternating multi-function ion exchange process is the self-regeneration of the resins.

  4. Dry-Column Flash Chromatography

    NASA Astrophysics Data System (ADS)

    Shusterman, Alan J.; McDougal, Patrick G.; Glasfeld, Arthur

    1997-10-01

    Dry-column flash chromatography is a safe, powerful, yet easily learned preparative chromatography technique. It has proven useful in research, and an adaptation of the technique for use in large teaching laboratories (general chemistry, organic chemistry) is described here. The student version is similar to vacuum filtration, uses the same compact, readily available glassware, and inexpensive and safe solvents (ethyl acetate and hexane) and adsorbent (Merck grade 60 silica gel). The technique is sufficiently simple and powerful that a beginning student can successfully resolve diastereomers on sample scales ranging from 100 mg to >1 g.

  5. Kinetic Studies of Biological Interactions By Affinity Chromatography

    PubMed Central

    Schiel, John E.; Hage, David S.

    2009-01-01

    The rates at which biological interactions occur can provide important information on the mechanism and behavior of such processes in living systems. This review will discuss how affinity chromatography can be used as a tool to examine the kinetics of biological interactions. This approach, referred to here as biointeraction chromatography, uses a column with an immobilized binding agent to examine the association or dissociation of this agent with other compounds. The use of HPLC-based affinity columns in kinetic studies has received particular attention in recent years. Advantages of using HPLC with affinity chromatography for this purpose include the ability to reuse the same ligand within a column for a large number of experiments, and the good precision and accuracy of this approach. A number of techniques are available for kinetic studies through the use of affinity columns and biointeraction chromatography. These approaches include plate height measurements, peak profiling, peak fitting, split-peak measurements, and peak decay analysis. The general principles for each of these methods are discussed in this review and some recent applications of these techniques are presented. The advantages and potential limitations of each approach are also considered. PMID:19391173

  6. [Analysis of rice leaves proteomes by liquid chromatography-tandem, mass spectrometry based on the purification using a novel affinity detergent removal spin column].

    PubMed

    Cao, Xiaolin; Gong, Jiadi; Chen, Mingxue; Yu, Shasha; Bian, Yingfang; Cao, Zhaoyun

    2014-11-01

    A purification method was established for the analysis of proteomes in rice leaves based on a novel detergent removal spin column (DRSC). The proteins were extracted by phenol protein extraction method followed by sodium dodecyl sulfate (SDS) lysis. The lysate was purified by the detergent removal spin column and the enzymolytic peptides were detected by the nanoflow liquid chromatography-hybrid linear trap quadrupole orbitrap mass spectrometry (nanoLC-LTQ/Orbitrap). In terms of SDS removal efficiencies and protein identification, the method of DRSC was compared with those of filter aided sample preparation (FASP) and acetone precipitation. As a result, there were good efficiencies ( > 95%) of SDS removal for the three methods. With the DRSC purification strategy, 563 proteins were identified from rice leaves, while only 196 and 306 proteins were identified by FASP and acetone precipitation procedures respectively, in spite of certain complementarities among these identified proteins by the three methods. DRSC is suitable for proteins with various relative molecular masses and pI values. However, there were similar losses of proteins with different relative molecular masses and pI values with the other two methods. Using the established method, 588 proteins were identified by once injection analysis. According to the molecular functions, 296 proteins with at least two identified peptides can be classified into eight categories with binding activity, enzyme activity, transporter activity, inhibitor activity, structural constitute, catalytic activity, other and unknown functions. The method provides technical reference for conducting rice proteomes.

  7. Tandem lectin affinity chromatography monolithic columns with surface immobilised concanavalin A, wheat germ agglutinin and Ricinus communis agglutinin-I for capturing sub-glycoproteomics from breast cancer and disease-free human sera.

    PubMed

    Selvaraju, Subhashini; El Rassi, Ziad

    2012-07-01

    In this study, a liquid-phase separation platform consisting of tandem lectin affinity chromatography was introduced for the selective capturing of sub-glycoproteomics that are affected in cancers, e.g. breast cancer. The platform is comprised of three monolithic columns with surface immobilised lectins including concanavalin A (Con A), wheat germ agglutinin (WGA) and Ricinus communis agglutinin-I (RCA-I). While WGA and Con A have specificities directed towards the core portion of N-glycans on the glycoprotein surface, RCA-I specifically interacts with the non-reducing terminal moieties of the outer chain structures of N-glycans. The effects of the order in which the three lectin columns were arranged in the tandem columns format were evaluated. The most suitable order proved to be WGA → Con A → RCA-I (denoted as WCR) as far as the number of captured proteins was concerned. The WCR tandem columns allowed the capture of 113 and 112 proteins from disease-free and breast cancer sera, respectively, corresponding to 75 and 65 non-redundant proteins, respectively. Using mass spectral count ratios and Q-Q plots yielded a panel of 23 non-redundant differentially expressed proteins (i.e. a panel of 23 candidate markers), which should in principle be more representative of a pathophysiological state than a single marker candidate.

  8. [Separation of osteoclasts by lectin affinity chromatography].

    PubMed

    Itokazu, M; Tan, A; Tanaka, S

    1991-09-01

    Newborn rat calvaria bone cells obtained by digestion were fractionated on columns of wheat-germ agglutinin (WGA) sepharose 6MB for osteoclast isolation. The initial nonspecific binding cells which were passed through the WGA sepharose column by a buffer acquired a high enzyme activity of alkaline phosphatase, but not that of acid phosphatase. However, elution of cells using a buffer with the addition of N-acetyl-D-glucosamine resulted in a high acid phosphatase activity but no alkaline phosphatase activity. The former WGA binding negative fraction enriched osteoblasts averaging 30 microns in size. The latter WGA binding positive fraction enriched osteoclasts ranging from 20 microns to 60 microns in size. The electron-microscope clearly demonstrated the cellular details of osteoclasts. Isolated cell counts showed a ratio of six to four. These results indicate that our method of osteoclast isolation is simple and useful in lectin affinity chromatography because all cells have sugar moieties on their surface and the binding of osteoclasts can be reversed by the addition of specific lectin-binding sugars to the eluting buffer.

  9. Ultra-fast liquid chromatography with tandem mass spectrometry determination of ochratoxin A in traditional Chinese medicines based on vortex-assisted solid-liquid microextraction and aptamer-affinity column clean-up.

    PubMed

    Yang, Xihui; Hu, Yichen; Kong, Weijun; Chu, Xianfeng; Yang, Meihua; Zhao, Ming; Ouyang, Zhen

    2014-11-01

    A rapid, selective, and sensitive ultra-fast liquid chromatography with tandem mass spectrometry method was developed for the determination of ochratoxin A in traditional Chinese medicines based on vortex-assisted solid-liquid microextraction and aptamer-affinity column clean-up. Through optimizing the sample pretreatment procedures and chromatographic conditions, good linearity (r(2) ≥ 0.9993), low limit of detection (0.5-0.8 μg/kg), and satisfactory recovery (83.54-94.44%) expressed the good reliability and applicability of the established method in various traditional Chinese medicines. Moreover, the aptamer-affinity column, prepared in-house, showed an excellent feasibility owing to its specific identification of ochratoxin A in various kinds of selected traditional Chinese medicines. The maximum adsorption amount and applicability value were 188.96 ± 10.56 ng and 72.3%, respectively. The matrix effects were effectively eliminated, especially for m/z 404.2→358.0 of ochratoxin A. The application of the developed method for screening the natural contamination levels of ochratoxin A in 25 random traditional Chinese medicines on the market in China indicated that only eight samples were contaminated with low levels below the legal limit (5.0 μg/kg) set by the European Union. This study provided a preferred choice for the rapid and accurate monitoring of ochratoxin A in complex matrices.

  10. PHARMACEUTICAL AND BIOMEDICAL APPLICATIONS OF AFFINITY CHROMATOGRAPHY: RECENT TRENDS AND DEVELOPMENTS

    PubMed Central

    Hage, David S.; Anguizola, Jeanethe A.; Bi, Cong; Li, Rong; Matsuda, Ryan; Papastavros, Efthimia; Pfaunmiller, Erika; Vargas, John; Zheng, Xiwei

    2012-01-01

    Affinity chromatography is a separation technique that has become increasingly important in work with biological samples and pharmaceutical agents. This method is based on the use of a biologically-related agent as a stationary phase to selectively retain analytes or to study biological interactions. This review discusses the basic principles behind affinity chromatography and examines recent developments that have occurred in the use of this method for biomedical and pharmaceutical analysis. Techniques based on traditional affinity supports are discussed, but an emphasis is placed on methods in which affinity columns are used as part of HPLC systems or in combination with other analytical methods. General formats for affinity chromatography that are considered include step elution schemes, weak affinity chromatography, affinity extraction and affinity depletion. Specific separation techniques that are examined include lectin affinity chromatography, boronate affinity chromatography, immunoaffinity chromatography, and immobilized metal ion affinity chromatography. Approaches for the study of biological interactions by affinity chromatography are also presented, such as the measurement of equilibrium constants, rate constants, or competition and displacement effects. In addition, related developments in the use of immobilized enzyme reactors, molecularly imprinted polymers, dye ligands and aptamers are briefly considered. PMID:22305083

  11. Affinity Chromatography of Lactate Dehydrogenase: An Experiment for the Undergraduate Biochemistry Laboratory.

    ERIC Educational Resources Information Center

    Anderson, Alexander J.

    1988-01-01

    Discusses a laboratory technique of enzyme purification by affinity chromatography as part of an undergraduate biochemical methodology course. Provides preparation details of the rat muscle homogenate and reagents. Proposes column requirements and assaying information. (MVL)

  12. Temperature programmable microfabricated gas chromatography column

    DOEpatents

    Manginell, Ronald P.; Frye-Mason, Gregory C.

    2003-12-23

    A temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by the integration of a resistive heating element and temperature sensing on the microfabricated column. Additionally, means are provided to thermally isolate the heated column from their surroundings. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.

  13. Protein purification using PDZ affinity chromatography.

    PubMed

    Walkup, Ward G; Kennedy, Mary B

    2015-04-01

    PDZ domains function in nature as protein-binding domains within scaffold and membrane-associated proteins. They comprise approximately 90 residues and undergo specific, high-affinity interactions with complementary C-terminal peptide sequences, other PDZ domains, and/or phospholipids. We have previously shown that the specific, strong interactions of PDZ domains with their ligands make them well suited for use in affinity chromatography. This unit provides protocols for the PDZ affinity chromatography procedure that are applicable for the purification of proteins that contain PDZ domains or PDZ domain-binding ligands, either naturally or introduced by genetic engineering. We detail the preparation of affinity resins composed of PDZ domains or PDZ domain peptide ligands coupled to solid supports. These resins can be used to purify proteins containing endogenous or genetically introduced PDZ domains or ligands, eluting the proteins with free PDZ domain peptide ligands.

  14. Kinetic studies of drug-protein interactions by using peak profiling and high-performance affinity chromatography: examination of multi-site interactions of drugs with human serum albumin columns.

    PubMed

    Tong, Zenghan; Schiel, John E; Papastavros, Efthimia; Ohnmacht, Corey M; Smith, Quentin R; Hage, David S

    2011-04-15

    Carbamazepine and imipramine are drugs that have significant binding to human serum albumin (HSA), the most abundant serum protein in blood and a common transport protein for many drugs in the body. Information on the kinetics of these drug interactions with HSA would be valuable in understanding the pharmacokinetic behavior of these drugs and could provide data that might lead to the creation of improved assays for these analytes in biological samples. In this report, an approach based on peak profiling was used with high-performance affinity chromatography to measure the dissociation rate constants for carbamazepine and imipramine with HSA. This approach compared the elution profiles for each drug and a non-retained species on an HSA column and control column over a board range of flow rates. Various approaches for the corrections of non-specific binding between these drugs and the support were considered and compared in this process. Dissociation rate constants of 1.7 (±0.2) s(-1) and 0.67 (±0.04) s(-1) at pH 7.4 and 37°C were estimated by this approach for HSA in its interactions with carbamazepine and imipramine, respectively. These results gave good agreement with rate constants that have determined by other methods or for similar solute interactions with HSA. The approach described in this report for kinetic studies is not limited to these particular drugs or HSA but can also be extended to other drugs and proteins.

  15. Affinity Chromatography in Nonionic Detergent Solutions

    NASA Astrophysics Data System (ADS)

    Robinson, Jack B.; Strottmann, James M.; Wick, Donald G.; Stellwagen, Earle

    1980-10-01

    Anionic dye affinity chromatography is commonly unproductive in the presence of nonionic detergents used to extract particulate proteins. Using lactate dehydrogenase as a model protein, Cibacron blue F3GA as a model dye, and Triton X-100 as a model detergent, we find that the dye is encapsulated in nonionic detergent micelles, rendering the dye incapable of ligation with the enzyme. However, the dye can be liberated from the micelles without altering the nonionic detergent concentration by addition of an anionic detergent, such as deoxycholate or sodium dodecyl sulfate, forming mixed anionic/nonionic micelles that displace the anionic dye. Encapsulation of the anionic detergents prevents their activity as protein denaturants. These observations have been successfully translated to the dye affinity chromatography of a detergent extract of brain particulate cyclic nucleotide phosphodiesterase.

  16. "Dry-column" chromatography of plant pigments

    NASA Technical Reports Server (NTRS)

    Woeller, F. H.; Lehwalt, M. F.; Oyama, V. I.

    1973-01-01

    Separation of plant pigments which can be accomplished on thin-layer silica plates with mixture of petroleum ether, halocarbon, acetone, and polar solvent can be readily translated into dry-column technique that yields reproducible chromatograms after elution in fashion of liquid chromatography with fluorimeter as detector. Best solvent system was found to be mixture of petroleum ether, dichloromethane, acetone, and ethyl acetate.

  17. Generation of an affinity column for antibody purification by intein-mediated protein ligation.

    PubMed

    Sun, Luo; Ghosh, Inca; Xu, Ming-Qun

    2003-11-01

    Coupling an antigenic peptide to a solid support is a crucial step in the affinity purification of a peptide-specific antibody. Conventional methods for generating reactive agarose, cellulose or other matrices for peptide conjugation are laborious and can result in a significant amount of chemical waste. In this report, we present a novel method for the facile production of a peptide affinity column by employing intein-mediated protein ligation (IPL) in conjunction with chitin affinity chromatography. A reactive thioester was generated at the C-terminal of the chitin binding domain (CBD) from the chitinase A1 of Bacillus circulans WL-2 by thiol-induced cleavage of the peptide bond between the CBD and a modified intein. Peptide epitopes possessing an N-terminal cysteine were ligated to the chitin bound CBD tag. We demonstrate that the resulting peptide columns permit the highly specific and efficient affinity purification of antibodies from animal sera.

  18. Non-planar microfabricated gas chromatography column

    DOEpatents

    Lewis, Patrick R.; Wheeler, David R.

    2007-09-25

    A non-planar microfabricated gas chromatography column comprises a planar substrate having a plurality of through holes, a top lid and a bottom lid bonded to opposite surfaces of the planar substrate, and inlet and outlet ports for injection of a sample gas and elution of separated analytes. A plurality of such planar substrates can be aligned and stacked to provide a longer column length having a small footprint. Furthermore, two or more separate channels can enable multi-channel or multi-dimensional gas chromatography. The through holes preferably have a circular cross section and can be coated with a stationary phase material or packed with a porous packing material. Importantly, uniform stationary phase coatings can be obtained and band broadening can be minimized with the circular channels. A heating or cooling element can be disposed on at least one of the lids to enable temperature programming of the column.

  19. Purification of cytochrome c oxidase by lysine-affinity chromatography.

    PubMed

    Felsch, J; Kotake, S; Copeland, R A

    1992-02-01

    A method for the purification of cytochrome c oxidase that is based on the affinity of this enzyme for polycations such as poly-L-lysine is described. When detergent extracts of bovine cardiac mitochondria were applied to either a poly-L-lysine-agarose or a lysine-Sepharose column at low ionic strength, cytochrome c oxidase was found to adhere tightly, whereas the bulk of the proteins were eluted by washing with the same buffer. The cytochrome c oxidase was eluted by application of a linear potassium chloride gradient to the columns. The resulting enzyme was identical to that obtained by more traditional purification methods in terms of its subunit composition, optical and resonance Raman spectra, and cytochrome c oxidizing activity. When detergent extracts of spheroplasts from Paracoccus denitrificans were applied to these columns, the cytochrome c oxidase from this organism was also found to adhere tightly. Thus this purification method appears applicable to both prokaryotic and eukaryotic forms of the enzyme. The advantages of this new purification method are that it is less labor intensive than the traditional procedure and less expensive than methods based on cytochrome c-affinity chromatography.

  20. Phosphopeptide Enrichment by Immobilized Metal Affinity Chromatography.

    PubMed

    Thingholm, Tine E; Larsen, Martin R

    2016-01-01

    Immobilized metal affinity chromatography (IMAC) has been the method of choice for phosphopeptide enrichment prior to mass spectrometric analysis for many years and it is still used extensively in many laboratories. Using the affinity of negatively charged phosphate groups towards positively charged metal ions such as Fe(3+), Ga(3+), Al(3+), Zr(4+), and Ti(4+) has made it possible to enrich phosphorylated peptides from peptide samples. However, the selectivity of most of the metal ions is limited, when working with highly complex samples, e.g., whole-cell extracts, resulting in contamination from nonspecific binding of non-phosphorylated peptides. This problem is mainly caused by highly acidic peptides that also share high binding affinity towards these metal ions. By lowering the pH of the loading buffer nonspecific binding can be reduced significantly, however with the risk of reducing specific binding capacity. After binding, the enriched phosphopeptides are released from the metal ions using alkaline buffers of pH 10-11, EDTA, or phosphate-containing buffers. Here we describe a protocol for IMAC using Fe(3+) for phosphopeptide enrichment. The principles are illustrated on a semi-complex peptide mixture.

  1. Purification of matrix metalloproteinases by column chromatography.

    PubMed

    Imai, Kazushi; Okada, Yasunori

    2008-01-01

    Matrix metalloproteinases (MMPs) are zinc endopeptidases composed of 23 members in humans, which belong to a subfamily of the metzincin superfamily. They play important roles in many pathophysiological events including development, organogenesis, angiogenesis, tissue remodeling and destruction, and cancer cell proliferation and progression by degradation of extracellular matrix (ECM) and non-ECM proteins and interaction with various molecules. Here, we present standard protocols for purification of native proMMPs (proMMP-1, -2, -3, -7, -9 and -10) and recombinant MT1-MMP (MMP-14) using conventional column chromatography. Purification steps comprise the initial common step [diethylaminoethyl (DEAE)-cellulose, Green A Dyematrex gel and gelatin-Sepharose columns], the second step for removal of nontarget proMMPs by immunoaffinity columns (anti-MMP-1 and/or anti-MMP-3 IgG-Sepharose columns) and the final step for further purification (IgG-Sepharose, DEAE-cellulose, Zn2+-chelate-Sepharose and/or gel filtration columns). Purified proMMPs and MMP are functionally active and suitable for biochemical analyses. The basic protocol for the purification from culture media takes approximately 7-10 d.

  2. Pepsin-modified chiral monolithic column for affinity capillary electrochromatography.

    PubMed

    Hong, Tingting; Chi, Cuijie; Ji, Yibing

    2014-11-01

    Pepsin-modified affinity monolithic capillary electrochromatography, a novel microanalysis system, was developed by the covalent bonding of pepsin on silica monolith. The column was successfully applied in the chiral separation of (±)-nefopam. Furthermore, the electrochromatographic performance of the pepsin-functionalized monolith for enantiomeric analysis was evaluated in terms of protein content, pH of running buffer, sample volume, buffer concentration, applied voltage, and capillary temperature. The relative standard deviation (%RSD) values of retention time (intraday <0.53, n = 10; interday <0.53, n = 10; column-to-column <0.70, n = 20; and batch-to-batch <0.80, n = 20) indicated satisfactory stability of these columns. No appreciable change was observed in retention and resolution for chiral recognition of (±)-nefopam in 50 days with 100 injections. The proteolytic activity of this stationary phase was further characterized with bovine serum albumin as substrate for online protein digestion. As for monolithic immobilized enzyme reactor, successive protein injections confirmed both the operational stability and ability to reuse the bioreactor for at least 20 digestions. It implied that the affinity monolith used in this research opens a new path of exploring particularly versatile class of enzymes to develop enzyme-modified affinity capillary monolith for enantioseparation.

  3. Highly efficient and low-cost purification of lysozyme: a novel tris(hydroxymethyl)aminomethane immobilized affinity column.

    PubMed

    Quan, Li; Cao, Qing; Li, Zhiyu; Li, Na; Li, Kean; Liu, Feng

    2009-03-01

    A highly efficient and low-cost affinity chromatography strategy for lysozyme (LZM) purification is reported. Using tris(hydroxymethyl)aminomethane (Tris) as ligand and macroporous silica spheres as matrix, a novel affinity column was prepared. The high specificity, stability and repeatability of this Tris immobilized affinity column were proved by LZM separations from protein mixture solutions for 20 circles and 6 months test. LZM purified from chicken egg white on the Tris affinity column had even higher purity than the commercial standard and well-maintained activity of 8287 U/mg (activity of commercial LZM was 8171 U/mg). The efficient affinity process avoiding expensive or fragile ligand would bring advantages to the routine production of LZM from chicken egg white.

  4. Profiling of drug binding proteins by monolithic affinity chromatography in combination with liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Xuepei; Wang, Tongdan; Zhang, Hanzhi; Han, Bing; Wang, Lishun; Kang, Jingwu

    2014-09-12

    A new approach for proteome-wide profiling drug binding proteins by using monolithic capillary affinity chromatography in combination with HPLC-MS/MS is reported. Two immunosuppresive drugs, namely FK506 and cyclosporin A, were utilized as the experimental models for proof-of-concept. The monolithic capillary affinity columns were prepared through a single-step copolymerization of the drug derivatives with glycidyl methacrylate and ethylene dimethacrylate. The capillary chromatography with the affinity monolithic column facilitates the purification of the drug binding proteins from the cell lysate. By combining the capillary affinity column purification and the shot-gun proteomic analysis, totally 33 FK506- and 32 CsA-binding proteins including all the literature reported target proteins of these two drugs were identified. Among them, two proteins, namely voltage-dependent anion-selective channel protein 1 and serine/threonine-protein phosphatase PGAM5 were verified by using the recombinant proteins. The result supports that the monolithic capillary affinity chromatography is likely to become a valuable tool for profiling of binding proteins of small molecular drugs as well as bioactive compounds.

  5. Affitins as robust tailored reagents for affinity chromatography purification of antibodies and non-immunoglobulin proteins.

    PubMed

    Béhar, Ghislaine; Renodon-Cornière, Axelle; Mouratou, Barbara; Pecorari, Frédéric

    2016-04-08

    Affinity chromatography is a convenient way of purifying proteins, as a high degree of purity can be reached in one step. The use of tags has greatly contributed to the popularity of this technique. However, the addition of tags may not be desirable or possible for the production of biopharmaceuticals. There is thus a need for tailored artificial affinity ligands. We have developed the use of archaeal extremophilic proteins as scaffolds to generate affinity proteins (Affitins). Here, we explored the potential of Affitins as ligand to design affinity columns. Affitins specific for human immunoglobulin G (hIgG), bacterial PulD protein, and chicken egg lysozyme were immobilized on an agarose matrix. The columns obtained were functional and highly selective for their cognate target, even in the presence of exogenous proteins as found in cell culture media, ascites and bacterial lysates, which result in a high degree of purity (∼95%) and recovery (∼100%) in a single step. Anti-hIgG Affitin columns withstand repetitive cycles of purification and cleaning-in-place treatments with 0.25 M NaOH as well as Protein A does. High levels of Affitin productions in Escherichia coli makes it possible to produce these affinity columns at low cost. Our results validate Affitins as a new class of tailored ligands for the affinity chromatography purification of potentially any proteins of interest including biopharmaceuticals.

  6. Novel neonicotinoid-agarose affinity column for Drosophila and Musca nicotinic acetylcholine receptors.

    PubMed

    Tomizawa, M; Latli, B; Casida, J E

    1996-10-01

    Neonicotinoids such as the insecticide imidacloprid (IMI) act as agonists at the insect nicotinic acetylcholine receptor (nAChR). Head membranes of Drosophila melanogaster and Musca domestica have a single high-affinity binding site for [3H]IMI with KD values of 1-2 nM and Bmax values of 560-850 fmol/mg of protein. Locusta and Periplaneta nAChRs isolated with an alpha-bungarotoxin (alpha-BGT)-agarose affinity column are known to be alpha-subunit homooligomers. This study uses 1-[N-(6-chloro-3-pyridylmethyl)-N-ethyl]amino-1-amino-2-nitroethene++ + (which inhibits [3H]IMI binding to Drosophila and Musca head membranes at 2-3 nM) to develop a neonicotinoid-agarose affinity column. The procedure-introduction of Triton-solubilized Drosophila or Musca head membranes into this neonicotinoid-based column, elution with IMI, and analysis by lithium dodecyl sulfate-polyacrylamicle gel electrophoresis-gives only three proteins (69, 66, and 61 kDa) tentatively assigned as putative subunits of the nAChR; the same three proteins are obtained with Musca using the alpha-BGT-agarose affinity column. Photoaffinity labeling of the Drosophila and Musca putative subunits from the neonicotinoid column with 125I-alpha-BGT-4-azidosalicylic acid gives a labeled derivative of 66-69 kDa. The yield is 2-5 micrograms of receptor protein from 1 g of Drosophila or Musca heads. Neonicotinoid affinity chromatography to isolate native Drosophila and Musca receptors will facilitate studies on the structure and function of insect nAChRs.

  7. Iminobiotin affinity columns and their application to retrieval of streptavidin.

    PubMed Central

    Hofmann, K; Wood, S W; Brinton, C C; Montibeller, J A; Finn, F M

    1980-01-01

    A method is described for the retrieval of streptavidin from the culture broth of Streptomyces avidinii. The key step in this procedure is the adsorption of streptavidin from culture concentrates to an affinity column in which iminobiotin is attached to AH-Sepharose 4B. This column binds streptavbidin at pH 11 and releases the protein at pH 4. The recovery of streptavidin is practically quantitative. The pH dependence of the iminobiotin-avidin affinity, discovered by Green [Green, N. M. (1966) Biochem. J. 101, 774-779], has thus found practical application. The streptavidin bound 4.07 +/- 0.02 mol of [14C]biotin per mol and was essentially homogeneous as judged by disc and slab gel electrophoresis. Streptavidin was extensively succinoylated without loss of biotin-binding capacity. The observations that 125I-labeled streptavidin and 125I-labeled succinoylstreptavidin are retained by iminobiotin-AH-Sepharose 4B columns at pH 7.5 and are eluted at pH 4.0 provides a convenient purification method for these iodinated proteins. The technique employed for the retrieval of streptavidin is generally applicable to the isolation of iminobiotinylated molecules. PMID:6933515

  8. Purification of baculovirus vectors using heparin affinity chromatography

    PubMed Central

    Nasimuzzaman, Md; Lynn, Danielle; van der Loo, Johannes CM; Malik, Punam

    2016-01-01

    Baculoviruses are commonly used for recombinant protein and vaccine production. Baculoviruses are nonpathogenic to vertebrates, have a large packaging capacity, display broad host and cell type tropism, infect both dividing and nondividing cells, and do not elicit strong immune or allergic responses in vivo. Hence, their use as gene delivery vehicles has become increasingly popular in recent years. Moreover, baculovirus vectors carrying mammalian regulatory elements can efficiently transduce and express transgenes in mammalian cells. Based on the finding that heparan sulfate, which is structurally similar to heparin, is an attachment receptor for baculovirus, we developed a novel scalable baculovirus purification method using heparin-affinity chromatography. Baculovirus supernatants were loaded onto a POROS heparin column, washed to remove unbound materials, and eluted with 1.5 mol/l NaCl, which yielded a recovery of purified baculovirus of 85%. After ultracentrifugation, baculovirus titers increased from 200- to 700-fold with overall yields of 26–29%. We further show that baculovirus particles were infectious, normal in morphology and size, despite high-salt elution and shear forces used during purification and concentration. Our chromatography-based purification method is scalable and, together with ultracentrifugation and/or tangential flow filtration, will be suitable for large-scale manufacturing of baculovirus stocks for protein and vaccine production and in gene therapy applications. PMID:27933303

  9. Affinity monolith chromatography: A review of principles and recent analytical applications

    PubMed Central

    Pfaunmiller, Erika L.; Paulemond, Marie Laura; Dupper, Courtney M.; Hage, David S.

    2012-01-01

    Affinity monolith chromatography (AMC) is a type of liquid chromatography that uses a monolithic support and a biologically-related binding agent as a stationary phase. AMC is a powerful method for the selective separation, analysis or studies of specific target compounds in a sample. This review discusses the basic principles of AMC and recent developments or applications of this method, with particular emphasis being given to work that has appeared in the last five years. Various materials that have been used to prepare columns for AMC are examined, including organic monoliths, silica monoliths, agarose monoliths and cryogels. These supports have been used in AMC for formats that have ranged from traditional columns to disks, microcolumns and capillaries. Many binding agents have also been employed in AMC, such as antibodies, enzymes, proteins, lectins, immobilized metal-ions and dyes. Some applications that have been reported with these binding agents in AMC are bioaffinity chromatography, immunoaffinity chromatography or immunoextraction, immobilized metal-ion affinity chromatography, dye-ligand affinity chromatography, chiral separations and biointeraction studies. Examples are presented from fields that include analytical chemistry, pharmaceutical analysis, clinical testing and biotechnology. Current trends and possible future directions in AMC are also discussed. PMID:23187827

  10. Polystyrene as an affinity chromatography matrix for the purification of antibodies.

    PubMed

    Staak, C; Salchow, F; Clausen, P H; Luge, E

    1996-08-14

    Affinity chromatography is used for the purification of diagnostic polyclonal antibodies in order to ensure specificity. Most commonly, activated bead-formed agarose or its derivatives are used as gel matrices. Alternative matrix materials have been described, but as yet they do not appear to offer important advantages. In this study, pulverized polystyrene (PS 158K, BASF, Mannheim, Germany) was used as a solid phase for the immobilisation of bovine immunoglobulins (Ig). Affinity chromatography was performed using these coated polystyrene beads as the column matrix material in the purification of anti-bovine Ig. The polystyrene binding capacity for the different bovine Ig classes was compared using the Mancini single radial immunodiffusion technique, and ELISA procedures were used to monitor the antibody reactivity of purified and unpurified antibodies. The degree of purification was comparable to the most commonly used procedure using gel matrices from activated bead-formed agarose (e.g. CNBr-activated Sepharose 4B, Pharmacia/LKB Biotechnology, Uppsala, Sweden), but the antibody yield per ml column volume was distinctly lower. In order to raise the yield, such polystyrene bead columns with immobilized antigen can be re-used without loss of activity or larger column volumes can be used to raise the binding capacity. The polystyrene material is quite durable, chemically and immunologically inert and has a long shelf life. We conclude that polystyrene based affinity chromatography is efficient, simple and cheap.

  11. Calcium-modulated conformational affinity chromatography. Application to the purification of calmodulin and S100 proteins.

    PubMed

    Fleminger, G; Neufeld, T; Star-Weinstock, M; Litvak, M; Solomon, B

    1992-04-24

    The purification of proteins by affinity chromatography is based on their highly specific interaction with an immobilized ligand followed by elution under conditions where their affinity towards the ligand is markedly reduced. Thus, a high-degree purification by a single chromatographic step is achieved. However, when several proteins in the crude mixture share affinity to a common immobilized ligand, they may not be resolved by affinity chromatography and subsequent "real" chromatographic purification steps may be required. It is shown that by using properly selected gradient elution conditions, the affinities of the various proteins towards the immobilized ligand may be gradually modulated and their separation may be achieved. This is exemplified by the isolation and separation of a group of Ca(2+)-activated proteins, Calmodulin, S100a and S100b, from bovine brain extract, using a melittin-Eupergit C affinity column which is developed with Ca(2+)-chelator gradients. As expected, separation of the three proteins into individual peaks, eluted in order of increasing affinity to the matrix, was obtained. Sigmoid selectivity curves calculated from the elution volumes under different elution conditions for each of the proteins were obtained, illustrating the chromatographic behaviour of the gradient affinity separation system.

  12. Using a box instead of a column for process chromatography.

    PubMed

    Ghosh, Raja

    2016-10-14

    Columns with relatively short bed-height to diameter ratios are frequently used for process-scale chromatography applications such as biopharmaceutical purification. Non-uniform flow distribution within such columns could result in broad and poorly resolved eluted peaks, which could in turn affect purity, recovery and productivity of the process. Different strategies centered on improved column header design have been proposed for addressing this problem. This paper describes a radically different approach, i.e. the use of a chromatography box (or chromato-box) instead of a column, for addressing the challenges posed by flow mal-distribution in process-scale, packed-bed chromatography devices. The design of the chromatography box devices used in this study is based on a laterally-fed membrane chromatography (or LFMC) device, that has been described and discussed in several recent papers. The performances of two chromatography box devices were compared with their equivalent columns in terms of sharpness and asymmetry of flow-through and eluted peaks, number of theoretical plates per metre, and peak resolution in binary and ternary protein separations. In each of the above comparisons, the chromatography box devices performed better than their equivalent columns, clearly indicating their potential as an alternative in process-scale chromatography applications.

  13. Stationary phases for packed-column supercritical fluid chromatography.

    PubMed

    Poole, Colin F

    2012-08-10

    The properties of silica-based, chemically bonded, packed column stationary phases used in supercritical fluid chromatography are described with a focus on column design and retention mechanisms. Supercritical fluid chromatography has benefited substantially from innovations in column design for liquid chromatography even if the separation conditions employed are generally quite different. The mobile phase composition and column operating conditions play an interactive role in modifying selectivity in supercritical fluid chromatography by altering analyte solubility in the mobile phase and through selective solvation of the stationary phase resulting in a wider range and intensity of intermolecular interactions with the analyte. The solvation parameter model is used to identify the main parameters that affect retention in supercritical fluid chromatography using carbon dioxide-methanol as a mobile phase and as a basis for column characterization to facilitate the identification of stationary phases with different separation characteristics for method development. As a caution it is pointed out that these column characterization methods are possibly a product of both the stationary phase chemistry and the column operating conditions and are suitable for use only when columns of similar design and with similar operating conditions are used.

  14. Single-step purification of native miraculin using immobilized metal-affinity chromatography.

    PubMed

    Duhita, Narendra; Hiwasa-Tanase, Kyoko; Yoshida, Shigeki; Ezura, Hiroshi

    2009-06-24

    Miraculin is a taste-modifying protein that can be isolated from miracle fruit ( Richadella dulcifica ), a shrub native to West Africa. It is able to turn a sour taste into a sweet taste. The commercial exploitation of this sweetness-modifying protein is underway, and a fast and efficient purification method to extract the protein is needed. We succeeded in purifying miraculin from miracle fruit in a single-step purification using immobilized metal-affinity chromatography (IMAC). The purified miraculin exhibited high purity (>95%) in reverse-phase high-performance liquid chromatography. We also demonstrated the necessity of its structure for binding to the nickel-IMAC column.

  15. Ion Exchange and Liquid Column Chromatography.

    ERIC Educational Resources Information Center

    Walton, Harold F.

    1980-01-01

    Emphasizes recent advances in principles and methodology in ion exchange and chromatography. Two tables list representative examples for inorganic ions and organic compounds. Cites 544 references. (CS)

  16. Kosmotropes enhance the yield of antibody purified by affinity chromatography using immobilized bacterial immunoglobulin binding proteins.

    PubMed

    Ngo, That T; Narinesingh, Dyer

    2008-01-01

    The yield of antibody purified using affinity chromatography on immobilized Protein A or Protein G was increased up to 5-fold (500%) by including kosmotropic salts in the binding buffer. The binding buffer is used to equilibrate the affinity column before applying a sample to the column and also to dilute the sample prior to loading onto the affinity column to optimize conditions for a maximal binding of antibodies to affinity gels. In this study, the kosmotropic salts that were effective in greatly increasing antibody binding to Protein A included both inorganic and organic salts of ammonium; sodium; or potassium sulfate, phosphate, polycarboxylates; for example, succinate, citrate, isocitrate, N-(2-hydroxyethylene diamine triacetate (HEDTA), ethylene diamine tetraacetate (EDTA), and ethylene glycol-O,O'-bis(2-aminoethyl)-N,N,N'N'-tetra acetate(EGTA). On an equal-molar basis, the greater the number of carboxylic groups within the polycarboxylate molecule, the greater the increase in the yield of the purified antibody that was observed. The data show that kosmotropes can be used as effective additives to enhance the binding of immunoglobulins to Protein A or Protein G gels with a resultant increase in the yield of the purified antibodies. Thus, it appears that strongly hydrated anions (citrate, sulfate, and phosphate) and weakly hydrated cations (ammonium, potassium) increase the yield of antibody purified on either Protein A or Protein G affinity gels.

  17. Optimising the design and operation of semi-continuous affinity chromatography for clinical and commercial manufacture.

    PubMed

    Pollock, James; Bolton, Glen; Coffman, Jon; Ho, Sa V; Bracewell, Daniel G; Farid, Suzanne S

    2013-04-05

    This paper presents an integrated experimental and modelling approach to evaluate the potential of semi-continuous chromatography for the capture of monoclonal antibodies (mAb) in clinical and commercial manufacture. Small-scale single-column experimental breakthrough studies were used to derive design equations for the semi-continuous affinity chromatography system. Verification runs with the semi-continuous 3-column and 4-column periodic counter current (PCC) chromatography system indicated the robustness of the design approach. The product quality profiles and step yields (after wash step optimisation) achieved were comparable to the standard batch process. The experimentally-derived design equations were incorporated into a decisional tool comprising dynamic simulation, process economics and sizing optimisation. The decisional tool was used to evaluate the economic and operational feasibility of whole mAb bioprocesses employing PCC affinity capture chromatography versus standard batch chromatography across a product's lifecycle from clinical to commercial manufacture. The tool predicted that PCC capture chromatography would offer more significant savings in direct costs for early-stage clinical manufacture (proof-of-concept) (∼30%) than for late-stage clinical (∼10-15%) or commercial (∼5%) manufacture. The evaluation also highlighted the potential facility fit issues that could arise with a capture resin (MabSelect) that experiences losses in binding capacity when operated in continuous mode over lengthy commercial campaigns. Consequently, the analysis explored the scenario of adopting the PCC system for clinical manufacture and switching to the standard batch process following product launch. The tool determined the PCC system design required to operate at commercial scale without facility fit issues and with similar costs to the standard batch process whilst pursuing a process change application. A retrofitting analysis established that the direct cost

  18. A Better Method for Filling Pasteur Pipet Chromatography Columns

    ERIC Educational Resources Information Center

    Ruekberg, Ben

    2006-01-01

    An alternative method for the preparation of Pasteur pipet chromatography columns is presented that allows the column to be filled with solvent without bubbles and allows greater control of fluid flow while the materials to be separated are added. Students are required to wear gloves and goggles and caution should be used while handling glass…

  19. Combining micro dry column chromatography and mass spectrometry

    NASA Technical Reports Server (NTRS)

    Bauman, A. J.

    1970-01-01

    Dry column chromatography principles applied in microscale produce technique to minimize time in preparing and analyzing colorless constituents of soluble mixtures. Glass pipette microcolumns filled with finely sieved adsorbents permit capillary attraction and separation in 3 to 15 minutes. Technique is adaptable to gas chromatography.

  20. Protein purification by aminosquarylium cyanine dye-affinity chromatography.

    PubMed

    Silva, M S; Graça, V C; Reis, L V; Santos, P F; Almeida, P; Queiroz, J A; Sousa, F

    2013-12-01

    The most selective purification method for proteins and other biomolecules is affinity chromatography. This method is based on the unique biological-based specificity of the biomolecule-ligand interaction and commonly uses biological ligands. However, these ligands may present some drawbacks, mainly because of their cost and lability. Dye-affinity chromatography overcomes the limitations of biological ligands and is widely used owing to the low cost of synthetic dyes and to their resistance to biological and chemical degradation. In this work, immobilized aminosquarylium cyanine dyes are used in order to exploit affinity interactions with standard proteins such as lysozyme, α-chymotrypsin and trypsin. These studies evaluate the affinity interactions occurring between the immobilized ligand and the different proteins, as a reflection of the sum of several molecular interactions, namely ionic, hydrophobic and van der Waals, spread throughout the structure, in a defined spatial manner. The results show the possibility of using an aminosquarylium cyanine dye bearing a N-hexyl pendant chain, with a ligand density of 1.8 × 10(-2) mmol of dye/g of chromatographic support, to isolate lysozyme, α-chymotrypsin and trypsin from a mixture. The application of a decreasing ammonium sulfate gradient resulted in the recovery of lysozyme in the flowthrough. On the other hand, α-chymotrypsin and trypsin were retained, involving different interactions with the ligand. In conclusion, this study demonstrates the potential applicability of ligands such as aminosquarylium cyanine dyes for the separation and purification of proteins by affinity chromatography.

  1. The Purification of a Blood Group A Glycoprotein: An Affinity Chromatography Experiment.

    ERIC Educational Resources Information Center

    Estelrich, J.; Pouplana, R.

    1988-01-01

    Describes a purification process through affinity chromatography necessary to obtain specific blood group glycoproteins from erythrocytic membranes. Discusses the preparation of erythrocytic membranes, extraction of glycoprotein from membranes, affinity chromatography purification, determination of glycoproteins, and results. (CW)

  2. Comparison of IMAC and MOAC for phosphopeptide enrichment by column chromatography.

    PubMed

    Negroni, Luc; Claverol, Stephane; Rosenbaum, Jean; Chevet, Eric; Bonneu, Marc; Schmitter, Jean-Marie

    2012-04-01

    Automated phosphopeptide enrichment prior to MS analysis by means of Immobilized Metal Affinity Chromatography (IMAC) and Metal Oxide Affinity Chromatography (MOAC) has been probed with packed columns. We compared POROS-Fe³⁺ and TiO₂ (respectively IMAC and MOAC media), using a simple mixture of peptides from casein-albumin and a complex mixture of peptides isolated from mouse liver. With theses samples, selectivity of POROS-Fe³⁺ and TiO₂ were pH dependant. In the case of liver extract, selectivity increased from 12-18% to 58-60% when loading buffer contained 0.1 M acetic acid or 0.1 M trifluoroacetic acid, respectively. However, with POROS-Fe³⁺ column, the number of identifications decreased from 356 phosphopeptides with 0.1 M acetic acid to 119 phosphopeptides with 0.1 M TFA. This decrease of binding capacity of POROS-Fe³⁺ was associated with strong Fe³⁺ leaching. Furthermore, repetitive use of IMAC-Fe³⁺ with the 0.5 M NH₄OH solution required for phosphopeptide elution induced Fe₂O₃ accumulation in the column. By comparison, MOAC columns packed with TiO₂ support do not present any problem of stability in the same conditions and provide a reliable solution for packed column phosphopeptide enrichment.

  3. Extension of the selection of protein chromatography and the rate model to affinity chromatography.

    PubMed

    Sandoval, G; Shene, C; Andrews, B A; Asenjo, J A

    2010-01-01

    The rational selection of optimal protein purification sequences, as well as mathematical models that simulate and allow optimization of chromatographic protein purification processes have been developed for purification procedures such as ion-exchange, hydrophobic interaction and gel filtration chromatography. This paper investigates the extension of such analysis to affinity chromatography both in the selection of chromatographic processes and in the use of the rate model for mathematical modelling and simulation. Two affinity systems were used: Blue Sepharose and Protein A. The extension of the theory developed previously for ion-exchange and HIC chromatography to affinity separations is analyzed in this paper. For the selection of operations two algorithms are used. In the first, the value of η, which corresponds to the efficiency (resolution) of the actual chromatography and, Σ, which determines the amount of a particular contaminant eliminated after each separation step, which determines the purity, have to be determined. It was found that the value of both these parameters is not generic for affinity separations but will depend on the type of affinity system used and will have to be determined on a case by case basis. With Blue Sepharose a salt gradient was used and with Protein A, a pH gradient. Parameters were determined with individual proteins and simulations of the protein mixtures were done. This approach allows investigation of chromatographic protein purification in a holistic manner that includes ion-exchange, HIC, gel filtration and affinity separations for the first time.

  4. Column precipitation chromatography: an approach to quantitative analysis of eigencolloids.

    PubMed

    Breynaert, E; Maes, A

    2005-08-01

    A new column precipitation chromatography (CPC) technique, capable of quantitatively measuring technetium eigencolloids in aqueous solutions, is presented. The CPC technique is based on the destabilization and precipitation of eigencolloids by polycations in a confined matrix. Tc(IV) colloids can be quantitatively determined from their precipitation onto the CPC column (separation step) and their subsequent elution upon oxidation to pertechnetate by peroxide (elution step). A clean-bed particle removal model was used to explain the experimental results.

  5. Aflatoxin metabolism in humans: detection of metabolites and nucleic acid adducts in urine by affinity chromatography

    SciTech Connect

    Groopman, J.D.; Donahue, P.R.; Zhu, J.Q.; Chen, J.S.; Wogan, G.N.

    1985-10-01

    A high-affinity IgM monoclonal antibody specific for aflatoxins was covalently bound to Sepharose 4B and used as a preparative column to isolate aflatoxin derivatives from the urine of people and experimental animals who had been exposed to the carcinogen environmentally or under laboratory conditions. Aflatoxin levels were quantified by radioimmunoassay and high-performance liquid chromatography after elution from the affinity column. In studies on rats injected with ( UC)aflatoxin B1, the authors identified the major aflatoxin-DNA adduct, 2,3-dihydro-2-(N7-guanyl)-3-hydroxy-aflatoxin B1 (AFB1-N7-Gua), and the oxidative metabolites M1 and P1 as the major aflatoxin species present in the urine. When this methodology was applied to human urine samples obtained from people from the Guangxi Province of China exposed to aflatoxin B1 through dietary contamination, the aflatoxin metabolites detected were also AFB1-N7-Gua and aflatoxins M1 and P1. Therefore, affinity chromatography using a monoclonal antibody represents a useful and rapid technique with which to isolate this carcinogen and its metabolites in biochemical epidemiology and for subsequent quantitative measurements, providing exposure information that can be used for risk assessment.

  6. A novel gigaporous GSH affinity medium for high-speed affinity chromatography of GST-tagged proteins.

    PubMed

    Huang, Yongdong; Zhang, Rongyue; Li, Juan; Li, Qiang; Su, Zhiguo; Ma, Guanghui

    2014-03-01

    Novel GSH-AP (phenoxyl agarose coated gigaporous polystyrene, Agap-co-PSt) microspheres were successfully prepared by introducing GSH ligand into hydrophilic AP microspheres pre-activated with 1,4-butanediol diglycidyl ether. The gigaporous structure and chromatographic properties of GSH-AP medium were evaluated and compared with commercial GSH Sepharose FF (GSH-FF) medium. The macropores (100-500nm) of gigaporous PSt microspheres were well maintained after coating with agarose and functionalized with GSH ligand. Hydrodynamic experiments showed that GSH-AP column had less backpressure and plate height than those of GSH-FF column at high flow velocity, which was beneficial for its use in high-speed chromatography. The presence of flow-through pores in GSH-AP microspheres also accelerated the mass transfer rate of biomolecules induced by convective flow, leading to high protein resolution and high dynamic binding capacity (DBC) of glutathione S-transferase (GST) at high flow velocity. High purity of GST and GST-tagged recombinant human interleukin-1 receptor antagonist (rhIL-1RA) were obtained from crude extract with an acceptable recovery yield within 1.5min at a velocity up to 1400cm/h. GSH-AP medium is promising for high-speed affinity chromatography for the purification of GST and GST-tagged proteins.

  7. Effect of column dimension on observed column efficiency in very high pressure liquid chromatography.

    PubMed

    Wu, Naijun; Bradley, Ashley C

    2012-10-26

    The effect of extra-column volume on observed linear velocity was investigated for columns of various internal diameters in very high pressure liquid chromatography. The results showed that the observed linear velocities were approximately 4.5, 9.5, 16.8, and 39.5% lower than the linear velocities corrected for the extra-column volume contribution for 4.6, 3.0, 2.1, and 1.0mm internal diameter columns, respectively. An empirical relationship between extra-column band broadening and extra-column volume was obtained using 50 cm long tubings of various internal diameters. The peak variance from the extra-column volume is near linearly proportional to the square of the extra-column volume for tubings with 0.0635-0.178 mm (0.025-0.07 in.) i.d. using a 50/50 acetonitrile/water mobile phase at flow rates greater than 0.3 mL/min. The effect of column internal diameter and column length on observed efficiency was studied using 50mm columns with four different column internal diameters and 2.1mm i.d columns with three different lengths. The results showed that the observed column efficiencies for 3.0, 2.1, and 1.0mm internal diameter columns were 18, 33, and 73% lower than that for a 4.6mm internal diameter column for benzophenone (k=5.5), respectively. An approximate 20% decrease in theoretical plate number was observed for propiophenone (k=3.3) using a 50 mm × 2.1 mm column packed with 1.7 μm particles compared to a 150 mm × 2.1 mm column packed with 5.0 μm particles, while the former column provided 9 fold faster separation. It is the column to extra column volume ratio instead of absolute extra-column volume that determines the degree of extra-column band-broadening in VHPLC.

  8. [Progresses in screening active compounds from herbal medicine by affinity chromatography].

    PubMed

    Feng, Ying-shu; Tong, Shan-shan; Xu, Xi-ming; Yu, Jiang-nan

    2015-03-01

    Affinity chromatography is a chromatographic method for separating molecules using the binding characteristics of the stationary phase with potential drug molecules. This method can be performed as a high throughput screening method and a chromatographic separation method to screen a variety of active drugs. This paper summarizes the history of affinity chromatography, screening technology of affinity chromatography, and application of affinity chromatography in screening bio-active compounds in herbal medicines, and then discusses its application prospects, in order to broaden applications of the affinity chromatography in drug screening.

  9. Design, testing, and simulation of microscale gas chromatography columns

    SciTech Connect

    Hudson, M.L.; Kottenstette, R.; Matzke, C.M.; Frye-Mason, G.C.; Shollenberger, K.A.; Adkins, D.R.; Wong, C.C.

    1998-08-01

    A microscale gas chromatography column is one component in a microscale chemistry laboratory for detecting chemical agents. Several columns were fabricated using the Bosch etch process which allows deep, high aspect ratio channels of rectangular cross-section. A design tool, based on analytical models, was developed to evaluate the effects of operating conditions and column specifications on separation resolution and time. The effects of slip flow, channel configuration, and cross-sectional shape were included to evaluate the differences between conventional round, straight columns and the microscale rectangular, spiral columns. Experimental data were obtained and compared with the predicted flowrates and theoretical number of plates. The design tool was then employed to select more optimum channel dimensions and operating conditions for high resolution separations.

  10. Procedure for rapid isolation of photosynthetic reaction centers using cytochrome c affinity chromatography

    SciTech Connect

    Brudvig, G.W.; Worland, S.T.; Sauer, K.

    1983-02-01

    Horse heart cytochrome c linked to Sepharose 4B is used to purify reaction centers from Rhodopseudomonas sphaeroides R-26. This procedure allows for an initial recovery of 80-90% of the bacterial reaction centers present in chromatophore membranes. High purity reaction centers (A/sub 280//A/sub 802/ < 1.30) can be obtained with a 30% recovery. Reaction centers from wild-type Rps. sphaeroides and Rps. capsulata also bind to a cytochrome c column. Cytochrome c affinity chromatography can also be used to isolate photosystem I complexes from spinach chloroplasts.

  11. Immobilized Metal Affinity Chromatography Coupled to Multiple Reaction Monitoring Enables Reproducible Quantification of Phospho-signaling*

    PubMed Central

    Kennedy, Jacob J.; Yan, Ping; Zhao, Lei; Ivey, Richard G.; Voytovich, Uliana J.; Moore, Heather D.; Lin, Chenwei; Pogosova-Agadjanyan, Era L.; Stirewalt, Derek L.; Reding, Kerryn W.; Whiteaker, Jeffrey R.; Paulovich, Amanda G.

    2016-01-01

    A major goal in cell signaling research is the quantification of phosphorylation pharmacodynamics following perturbations. Traditional methods of studying cellular phospho-signaling measure one analyte at a time with poor standardization, rendering them inadequate for interrogating network biology and contributing to the irreproducibility of preclinical research. In this study, we test the feasibility of circumventing these issues by coupling immobilized metal affinity chromatography (IMAC)-based enrichment of phosphopeptides with targeted, multiple reaction monitoring (MRM) mass spectrometry to achieve precise, specific, standardized, multiplex quantification of phospho-signaling responses. A multiplex immobilized metal affinity chromatography- multiple reaction monitoring assay targeting phospho-analytes responsive to DNA damage was configured, analytically characterized, and deployed to generate phospho-pharmacodynamic curves from primary and immortalized human cells experiencing genotoxic stress. The multiplexed assays demonstrated linear ranges of ≥3 orders of magnitude, median lower limit of quantification of 0.64 fmol on column, median intra-assay variability of 9.3%, median inter-assay variability of 12.7%, and median total CV of 16.0%. The multiplex immobilized metal affinity chromatography- multiple reaction monitoring assay enabled robust quantification of 107 DNA damage-responsive phosphosites from human cells following DNA damage. The assays have been made publicly available as a resource to the community. The approach is generally applicable, enabling wide interrogation of signaling networks. PMID:26621847

  12. Identification of proteins interacting with ammodytoxins in Vipera ammodytes ammodytes venom by immuno-affinity chromatography.

    PubMed

    Brgles, Marija; Kurtović, Tihana; Kovačič, Lidija; Križaj, Igor; Barut, Miloš; Lang Balija, Maja; Allmaier, Günter; Marchetti-Deschmann, Martina; Halassy, Beata

    2014-01-01

    In order to perform their function, proteins frequently interact with other proteins. Various methods are used to reveal protein interacting partners, and affinity chromatography is one of them. Snake venom is composed mostly of proteins, and various protein complexes in the venom have been found to exhibit higher toxicity levels than respective components separately. Complexes can modulate envenomation activity of a venom and/or potentiate its effect. Our previous data indicate that the most toxic components of the Vipera ammodytes ammodytes (Vaa) venom isolated so far-ammodytoxins (Atxs)-are contributing to the venom's toxicity only moderately; therefore, we aimed to explore whether they have some interacting partner(s) potentiating toxicity. For screening of possible interactions, immuno-affinity chromatography combined with identification by mass spectrometry was used. Various chemistries (epoxy, carbonyldiimidazole, ethylenediamine) as well as protein G functionality were used to immobilize antibodies on monolith support, a Convective Interaction Media disk. Monoliths have been demonstrated to better suit the separation of large biomolecules. Using such approach, several proteins were indicated as potential Atx-binding proteins. Among these, the interaction of Atxs with a Kunitz-type inhibitor was confirmed by far-Western dot-blot and surface plasmon resonance measurement. It can be concluded that affinity chromatography on monolithic columns combined with mass spectrometry identification is a successful approach for screening of protein interactions and it resulted with detection of the interaction of Atx with Kunitz-type inhibitor in Vaa venom for the first time.

  13. Column Chromatography To Obtain Organic Cation Sorption Isotherms.

    PubMed

    Jolin, William C; Sullivan, James; Vasudevan, Dharni; MacKay, Allison A

    2016-08-02

    Column chromatography was evaluated as a method to obtain organic cation sorption isotherms for environmental solids while using the peak skewness to identify the linear range of the sorption isotherm. Custom packed HPLC columns and standard batch sorption techniques were used to intercompare sorption isotherms and solid-water sorption coefficients (Kd) for four organic cations (benzylamine, 2,4-dichlorobenzylamine, phenyltrimethylammonium, oxytetracycline) with two aluminosilicate clay minerals and one soil. A comparison of Freundlich isotherm parameters revealed isotherm linearity or nonlinearity was not significantly different between column chromatography and traditional batch experiments. Importantly, skewness (a metric of eluting peak symmetry) analysis of eluting peaks can establish isotherm linearity, thereby enabling a less labor intensive means to generate the extensive data sets of linear Kd values required for the development of predictive sorption models. Our findings clearly show that column chromatography can reproduce sorption measures from conventional batch experiments with the benefit of lower labor-intensity, faster analysis times, and allow for consistent sorption measures across laboratories with distinct chromatography instrumentation.

  14. Evaluating two process scale chromatography column header designs using CFD.

    PubMed

    Johnson, Chris; Natarajan, Venkatesh; Antoniou, Chris

    2014-01-01

    Chromatography is an indispensable unit operation in the downstream processing of biomolecules. Scaling of chromatographic operations typically involves a significant increase in the column diameter. At this scale, the flow distribution within a packed bed could be severely affected by the distributor design in process scale columns. Different vendors offer process scale columns with varying design features. The effect of these design features on the flow distribution in packed beds and the resultant effect on column efficiency and cleanability needs to be properly understood in order to prevent unpleasant surprises on scale-up. Computational Fluid Dynamics (CFD) provides a cost-effective means to explore the effect of various distributor designs on process scale performance. In this work, we present a CFD tool that was developed and validated against experimental dye traces and tracer injections. Subsequently, the tool was employed to compare and contrast two commercially available header designs.

  15. Novel Design for Centrifugal Countercurrent Chromatography: I. Zigzag Toroidal Column

    PubMed Central

    Yang, Yi; Aisa, Haji Akber; Ito, Yoichiro

    2009-01-01

    The toroidal coil using an equilateral triangular core has improved both retention of the stationary phase and peak resolution of the conventional toroidal coil in centrifugal countercurrent chromatography. To further improve the retention of stationary phase and peak resolution, a novel zigzag toroidal coil was designed and the performance of the system was evaluated at various flow rates. The results indicated that both retention of stationary phase and peak resolution were improved as the flow rate was decreased. Modification of the tubing by pressing at given intervals with a pair of pliers improved the peak resolution without increasing the column pressure. All these separations were performed under low column pressure indicating the separation can be further improved by increasing the column length and/or revolution speed without damaging the separation column. PMID:20046954

  16. A simple parallel gas chromatography column screening system.

    PubMed

    Schafer, Wes; Hamilton, Simon E; Pirzada, Zainab; Welch, Christopher J

    2012-01-01

    A simple approach to the automated screening of four different columns on a single gas chromatography (GC) instrument is used for rapid chiral GC method development. Configuration of a conventional GC instrument with a second autosampler and several inexpensive Y-splitters enables simultaneous evaluation of two different columns, allowing a total of four different columns to be evaluated in two automated back to back runs. The resulting system affords a simple and effective approach to chiral GC method development that speeds analysis while eliminating the need for slow and tedious manual interchange of columns. An example of developing a rapid isothermal GC method from the screening results obtained by the instrument is also shown.

  17. Analysis of Cordyceps by multi-column liquid chromatography.

    PubMed

    Qian, Zhengming; Li, Shaoping

    2017-03-01

    Cordyceps is a famous traditional Chinese medicine (TCM) that has been used in China for hundreds of years. In the present study a multi-column liquid chromatography (MC-LC) system was developed for the qualitative analysis of macromolecules and micromolecules in Cordyceps. The MC-LC system includes a size exclusion pre-column, a size exclusion column (SEC) and a reversed phase column (RP) which were controlled by column-switching valves. The sample was separated by the size exclusion pre-column into two fractions (macromolecules and micromolecules). These fractions were further separated on SEC and RP columns, respectively. A diode array detector (DAD) and a mass spectrometer (MS) were used to detect the components. This MC-LC method was utilized for analysis of Cordyceps samples. Two macromolecular peaks and 15 micromolecular peaks were found in Cordyceps, and 11 of the micromolecular peaks were identified as adenosine-5'-monophosphate (AMP), phenylalanine, uridine, hypoxanthine, inosine, guanine, guanosine, deoxyadenosine-5'-monophosphate (dAMP), adenosine, adenine and cordycepin (or its isomer). This method is useful for quality control of Cordyceps.

  18. Rapid column heating method for subcritical water chromatography.

    PubMed

    Fogwill, Michael O; Thurbide, Kevin B

    2007-01-19

    A novel resistive heating method is presented for subcritical water chromatography (SWC) that provides higher column heating rates than those conventionally obtained from temperature-programmed gas chromatography (GC) convection ovens. Since the polarity of water reduces dramatically with increasing temperature, SWC employs column heating to achieve gradient elution. As such, the rate at which the mobile phase is heated directly impacts the magnitude of such gradients applied in SWC. Data from the current study demonstrate that the maximum column heating rate attainable in a typical SWC apparatus (i.e. using a GC convection oven) is around 10 degrees C/min, even at instrument oven settings of over three times this value. Conversely, by wrapping the separation column with ceramic insulation and a resistively heated wire, the column heating rates are increased five-fold. As a result, elution times can be greatly decreased in SWC employing gradients. Separations of standard alcohol test mixtures demonstrate that the retention time of the latest eluting component decreases by 35 to 50% using the prototype method. Additionally, solute retention times in this mode deviate by less than 1% RSD over several trials, which compares very well to those obtained using a conventional GC convection oven. Results suggest that the developed method can be a useful alternative heating technique in SWC.

  19. Purification of prenylated proteins by affinity chromatography on cyclodextrin-modified agarose

    PubMed Central

    Chung, Jinhwa A.; Wollack, James W.; Hovlid, Marisa L.; Okesli, Ayse; Chen, Yan; Mueller, Joachim D.; Distefano, Mark D.; Taton, T. Andrew

    2009-01-01

    Although protein prenylation is widely studied, there are few good methods for isolating prenylated proteins from their non-prenylated relatives. We report that crosslinked agarose (e.g., Sepharose) chromatography media that has been chemically functionalized with β-cyclodextrin (β-CD) is extremely effective in affinity chromatography of prenylated proteins. In this study, a variety of proteins with C-terminal prenylation target (“CAAX box”) sequences were enzymatically prenylated in vitro with natural and non-natural prenyl diphosphate substrates. The prenylated protein products could then be isolated from starting materials by gravity chromatography or fast protein liquid chromatography (FPLC) on a β-CD-Sepharose column. One particular prenylation reaction—farnesylation of a mCherry-CAAX fusion construct—was studied in detail. In this case, purified farnesylated product was unambiguously identified by electrospray mass spectrometry. In addition, when mCherry-CAAX was prenylated with a non-natural, functional isoprenoid substrate, the functional group was maintained by chromatography on β-CD-Sepharose, such that the resulting protein could be selectively bound at its C terminus to complementary functionality on a solid substrate. Finally, β-CD-Sepharose FPLC was used to isolate prenylated mCherry-CAAX from crude HeLa cell lysate, as a model for purifying prenylated proteins from cell extracts. We propose that this method could be generally useful to the community of researchers studying protein prenylation. PMID:18834849

  20. Application of Frontal Affinity Chromatography to Study the Biomolecular Interactions with Trypsin.

    PubMed

    Hu, YuanYuan; Qian, Junqing; Guo, Hui; Jiang, ShengLan; Zhang, Zheng

    2015-07-01

    Trypsin is a serine protease that has been proposed as a potential therapeutic target for metabolic disorders and malignancy diseases, thus the identification of biomolecular interactions of compounds to trypsin could be of great therapeutic importance. In this study, trypsin was immobilized on a monolithic silica capillary column via sol-gel. The binding properties of four small molecules (daidzin, genistin, matrine and oxymatrine) to trypsin were examined using the trypsin affinity columns by frontal analysis. The results indicate that the matrine (dissociation constant, Kd = 7.904 μM) has stronger interaction with trypsin than the oxymatrine (Kd = 8.204 μM), whereas daidzin and genistin were nearly have no affinity with trypsin. The results demonstrated that the frontal affinity chromatography can be used for the direct determination of protein-protease inhibitor binding interactions and have several significant advantages, including easy fabricating, reproducible, minimal technological requirements and potential to become a reliable alternative for quantitative studies of biomolecular interactions.

  1. Glycolipid class profiling by packed-column subcritical fluid chromatography.

    PubMed

    Deschamps, Frantz S; Lesellier, Eric; Bleton, Jean; Baillet, Arlette; Tchapla, Alain; Chaminade, Pierre

    2004-06-18

    The potential of packed-column subcritical fluid chromatography (SubFC) for the separation of lipid classes has been assessed in this study. Three polar stationary phases were checked: silica, diol, and poly(vinyl alcohol). Carbon dioxide (CO2) with methanol as modifier was used as mobile phase and detection performed by evaporative light scattering detection. The influence of methanol content, temperature, and pressure on the chromatographic behavior of sphingolipids and glycolipids were investigated. A complete separation of lipid classes from a crude wheat lipid extract was achieved using a modifier gradient from 10 to 40% methanol in carbon dioxide. Solute selectivity was improved using coupled silica and diol columns in series. Because the variation of eluotropic strength depending on the fluid density changes, a normalized separation factor product (NSP) was used to select the nature, the number and the order of the columns to reach the optimum glycolipid separation.

  2. Reinforcement of frontal affinity chromatography for effective analysis of lectin-oligosaccharide interactions.

    PubMed

    Hirabayashi, J; Arata, Y; Kasai, K

    2000-08-25

    Frontal affinity chromatography is a method for quantitative analysis of biomolecular interactions. We reinforced it by incorporating various merits of a contemporary liquid chromatography system. As a model study, the interaction between an immobilized Caenorhabditis elegans galectin (LEC-6) and fluorescently labeled oligosaccharides (pyridylaminated sugars) was analyzed. LEC-6 was coupled to N-hydroxysuccinimide-activated Sepharose 4 Fast Flow (100 microm diameter), and packed into a miniature column (e.g., 10 x 4.0 mm, 0.126 ml). Twelve pyridylaminated oligosaccharides were applied to the column through a 2-ml sample loop, and their elution patterns were monitored by fluorescence. The volume of the elution front (V) determined graphically for each sample was compared with that obtained in the presence of an excess amount of hapten saccharide, lactose (V0); and the dissociation constant, Kd, was calculated according to the literature [K. Kasai, Y. Oda, M. Nishikawa, S. Ishii, J. Chromatogr. 376 (1986) 33]. This system also proved to be useful for an inverse confirmation; that is, application of galectins to an immobilized glycan column (in the present case, asialofetuin was immobilized on Sepharose 4 Fast Flow), and the elution profiles were monitored by fluorescence based on tryptophan. The relative affinity of various galectins for asialofetuin could be easily compared in terms of the extent of retardation. The newly constructed system proved to be extremely versatile. It enabled rapid (analysis time 12 min/cycle) and sensitive (20 nM for pyridylaminated derivatives, and 1 microg/ml for protein) analyses of lectin-carbohydrate interactions. It should become a powerful tool for elucidation of biomolecular interactions, in particular for functional analysis of a large number of proteins that should be the essential issues of post-genome projects.

  3. Advance chromatin extraction improves capture performance of protein A affinity chromatography.

    PubMed

    Nian, Rui; Zhang, Wei; Tan, Lihan; Lee, Jeremy; Bi, Xeuzhi; Yang, Yuansheng; Gan, Hui Theng; Gagnon, Pete

    2016-01-29

    Practical effects of advance chromatin removal on performance of protein A affinity chromatography were evaluated using a caprylic acid-allantoin-based extraction method. Lacking this treatment, the practice of increasing loading residence time to increase capacity was shown to increase host protein contamination of the eluted IgG. Advance chromatin extraction suspended that compromise. Protein A ligand leakage from columns loaded with chromatin-extracted harvest was half the level observed on protein A columns loaded with non-extracted harvest. Columns loaded with chromatin-extracted harvest were cleaned more effectively by 50-100mM NaOH than columns loaded with non-extracted harvest that were cleaned with 250-500mM NaOH. Two protein A media with IgG capacities in excess of 50g/L were loaded with chromatin-extracted harvest, washed with 2.0M NaCl before elution, and the eluted IgG fraction titrated to pH 5.5 before microfiltration. Host protein contamination in the filtrate was reduced to <1ppm, DNA to <1ppb, protein A leakage to 0.5ppm, and aggregates to 1.0%. Caprylic acid and allantoin were both reduced below 5ppm. Step recovery of IgG was 99.4%. Addition of a single polishing step reduced residual protein A beneath the level of detection and aggregates to <0.1%. Overall process recovery including chromatin extraction was 90%.

  4. Virus inactivation by protein denaturants used in affinity chromatography.

    PubMed

    Roberts, Peter L; Lloyd, David

    2007-10-01

    Virus inactivation by a number of protein denaturants commonly used in gel affinity chromatography for protein elution and gel recycling has been investigated. The enveloped viruses Sindbis, herpes simplex-1 and vaccinia, and the non-enveloped virus polio-1 were effectively inactivated by 0.5 M sodium hydroxide, 6 M guanidinium thiocyanate, 8 M urea and 70% ethanol. However, pH 2.6, 3 M sodium thiocyanate, 6 M guanidinium chloride and 20% ethanol, while effectively inactivating the enveloped viruses, did not inactivate polio-1. These studies demonstrate that protein denaturants are generally effective for virus inactivation but with the limitation that only some may inactivate non-enveloped viruses. The use of protein denaturants, together with virus reduction steps in the manufacturing process should ensure that viral cross contamination between manufacturing batches of therapeutic biological products is prevented and the safety of the product ensured.

  5. Contamination from an affinity column: an encounter with a new villain in the world of membrane-protein crystallization.

    PubMed

    Panwar, Pankaj; Deniaud, Aurélien; Pebay-Peyroula, Eva

    2012-10-01

    Attempts to crystallize AtNTT1, a chloroplast ATP/ADP transporter from Arabidopsis thaliana, revealed an unexpected contaminant, Strep-Tactin, a variant of streptavidin that was used during purification of the protein. Although it was present in very small amounts, crystals of Strep-Tactin were reproducibly grown from the AtNTT1 solution. AtNTT1 was overexpressed in Escherichia coli and purified from detergent-solubilized membrane fractions using Strep-Tactin affinity chromatography based on an engineered streptavidin. The contamination of protein solutions purified on Strep-Tactin columns has never been described previously and seems to be specific to membrane proteins solubilized in detergents. Trace amounts of Strep-Tactin were observed to be eluted from a Strep-Tactin column using several routinely used detergents, illustrating their possible role in the contamination. This finding raises an alarm and suggests caution in membrane-protein purification using Strep-Tactin affinity columns, where detergents are essential components. The small crystals of contaminant protein led to the structure at 1.9 Å resolution of Strep-Tactin in complex with desthiobiotin.

  6. Automated hydrophobic interaction chromatography column selection for use in protein purification.

    PubMed

    Murphy, Patrick J M; Stone, Orrin J; Anderson, Michelle E

    2011-09-21

    In contrast to other chromatographic methods for purifying proteins (e.g. gel filtration, affinity, and ion exchange), hydrophobic interaction chromatography (HIC) commonly requires experimental determination (referred to as screening or "scouting") in order to select the most suitable chromatographic medium for purifying a given protein (1). The method presented here describes an automated approach to scouting for an optimal HIC media to be used in protein purification. HIC separates proteins and other biomolecules from a crude lysate based on differences in hydrophobicity. Similar to affinity chromatography (AC) and ion exchange chromatography (IEX), HIC is capable of concentrating the protein of interest as it progresses through the chromatographic process. Proteins best suited for purification by HIC include those with hydrophobic surface regions and able to withstand exposure to salt concentrations in excess of 2 M ammonium sulfate ((NH(4;))(2;)SO(4;)). HIC is often chosen as a purification method for proteins lacking an affinity tag, and thus unsuitable for AC, and when IEX fails to provide adequate purification. Hydrophobic moieties on the protein surface temporarily bind to a nonpolar ligand coupled to an inert, immobile matrix. The interaction between protein and ligand are highly dependent on the salt concentration of the buffer flowing through the chromatography column, with high ionic concentrations strengthening the protein-ligand interaction and making the protein immobile (i.e. bound inside the column) (2). As salt concentrations decrease, the protein-ligand interaction dissipates, the protein again becomes mobile and elutes from the column. Several HIC media are commercially available in pre-packed columns, each containing one of several hydrophobic ligands (e.g. S-butyl, butyl, octyl, and phenyl) cross-linked at varying densities to agarose beads of a specific diameter (3). Automated column scouting allows for an efficient approach for determining

  7. Preparation and evaluation of molecularly imprinted polymer liquid chromatography column for the separation of Cathine enantiomers

    PubMed Central

    Balamurugan, Krishnamoorthy; Gokulakrishnan, Kannan; Prakasam, Tangirala

    2011-01-01

    In this study molecular imprinting technology was employed to prepare a specific affinity sorbent for the resolution of Cathine, a chiral drug product. The molecularly imprinted polymer (MIP) was prepared by non-covalent molecular imprinting with either (+) or (−)-Cathine (threo-2-amino-1-hydroxy-1-phenyl propane; norpseudoephedrine) as the template. Methacrylic acid and ethylene glycol di-methacrylate were copolymerized in the presence of the template molecule. The bulk polymerization was carried out in chloroform with 2,2′-azobisisobutyronitrile as the initiator, at 5 °C and under UV radiation. The resulting MIP was ground into powders, which were slurry packed into analytical columns. After removal of template molecules, the MIP-packed columns were found to be effective for the resolution of (±)-Cathine racemates. The separation factor for the enantiomers ranged between 1.5 and 2.4 when the column was packed with MIP prepared with (+)-Cathine as the template. A separation factor ranging from 1.6 to 2.9 could be achieved from the column packed with MIP, prepared with (−)-Cathine as the template. Although the separation factor was higher with that previously obtained from reversed-phase column chromatography following derivatization with a chiral agent, elution peaks were broader due to the heterogeneity of binding sites on MIP particles and the possible non-specific interaction. PMID:23960776

  8. Comparison of the kinetic performance of different columns for fast liquid chromatography, emphasizing the contributions of column end structure.

    PubMed

    Lambert, Nándor; Miyazaki, Shota; Ohira, Masayoshi; Tanaka, Nobuo; Felinger, Attila

    2016-11-18

    The kinetic performance of five chromatographic columns designed for fast liquid chromatography with different column packing materials - including fully porous (2.0 and 1.9μm particles), core-shell (2.6μm particles) or monolithic packings - with identical column dimensions (2.1×50mm) was tested. Since the tested monolithic column showed systematically better efficiency for early eluting compounds than the packed columns, an additional band broadening effect was suspected for the packed columns. The effects of the presence of the frits and the bed heterogeneity of the columns near the frits were characterized by a column-reversal method. It has been shown that significant differences - even 20-25% difference in efficiency - can exist between the two ends of the packed columns, while the monolithic column shows rather similar performance at either column end.

  9. Partial purification of the microsomal rat liver iodothyronine deiodinase. II. Affinity chromatography.

    PubMed

    Mol, J A; van den Berg, T P; Visser, T J

    1988-02-01

    Iodothyronine deiodinase has been solubilized and purified approximately 2400 times from liver microsomal fractions of male Wistar rats pretreated with thyroxine. The deiodinase was solubilized with 1% cholate, and stripped of adhering phospholipids by ammonium sulfate precipitation followed by solubilization with the non-ionic detergent Emulgen 911. The enzyme was further purified by successive ion-exchange chromatography on DEAE-Sephacel and Cellex-P and affinity chromatography on 3,3',5-triiodothyronine-Sepharose. Finally, the deiodinase was reacted with 6-propionyl-2-thiouracil-Sepharose, a derivative of the mechanism-based inhibitor 6-propyl-2-thiouracil. Covalent binding was observed only in the presence of substrate in agreement with the proposed mechanism of deiodination. The deiodinase was eluted from the affinity column by reduction of the enzyme-propylthiouracil mixed disulfide with 50 mM dithiothreitol. The enzyme was approximately 50% pure as judged by SDS-PAGE, exhibiting a subunit molecular weight of 25,000. This preparation was equally enriched in outer ring and inner ring deiodinase activities in keeping with the view that both are intrinsic to a single, type I deiodinase.

  10. If You Were a Molecule in a Chromatography Column, What Would You See?

    ERIC Educational Resources Information Center

    Mattice, John

    2008-01-01

    To visualize what takes place in a chromatography column, enlarge the molecules to human size and expand the columns to keep the ratio of size of molecule to size of column the same. If we were molecules, what would the columns be like? A typical gas chromatography (GC) capillary column would be 50 x 10 [superscript 6] 6 km (31 million mi) long,…

  11. Direct probing of chromatography columns by laser-induced fluorescence

    NASA Astrophysics Data System (ADS)

    McGuffin, V. L.

    1992-12-01

    This report summarizes the progress and accomplishments of this research project from 1 Sep. 1989 to 28 Feb. 1993. During this period, we have accomplished all of the primary scientific objectives of the research proposal: (1) constructed and evaluated a laser-induced fluorescence detection system that allows direct examination of the chromatographic column, (2) examined nonequilibrium processes that occur upon solute injection and elution, (3) examined solute retention in liquid chromatography as a function of temperature and pressure, (4) examined solute zone dispersion in liquid chromatography as a function of temperature and pressure, and (5) developed appropriate theoretical models to describe these phenomena. In each of these studies, substantial knowledge has been gained of the fundamental processes that are responsible for chromatographic separations. In addition to these primary research objectives, we have made significant progress in three related areas: (1) examined pyrene as a fluorescent polarity probe in supercritical fluids and liquids as a function of temperature and pressure, (2) developed methods for the class-selective identification of polynuclear aromatic hydrocarbons in coal-derived fluids by microcolumn liquid chromatography with fluorescence quenching detection, and (3) developed methods for the determination of saturated and unsaturated (including omega-3) fatty acids in fish oil extracts by microcolumn liquid chromatography with laser-induced fluorescence detection. In these studies, the advanced separation and detection techniques developed in our laboratory are applied to practical problems of environmental and biomedical significance.

  12. Purification and characterization of a new type lactose-binding Ulex europaeus lectin by affinity chromatography.

    PubMed

    Konami, Y; Yamamoto, K; Osawa, T

    1991-02-01

    A new type lactose-binding lectin was purified from extracts of Ulex europaeus seeds by affinity chromatography on a column of galactose-Sepharose 4B, followed by gel filtration on Sephacryl S-300. This lectin, designated as Ulex europaeus lectin III (UEA-III), was found to be inhibited by lactose. The dimeric lectin is a glycoprotein with a molecular mass of 70,000 Da; it consists of two apparently identical subunits of a molecular mass of 34,000 Da. Compositional analysis showed that this lectin contains 30% carbohydrate and a large amount of aspartic acid, serine and valine, but no sulfur-containing amino acids. The N-terminal amino-acid sequences of L-fucose-binding Ulex europaeus lectin I (UEA-I) and di-N-acetylchitobiose-binding Ulex europaeus lectin II (UEA-II), both of which we have already purified and characterized, and that of UEA-III were determined and compared.

  13. Microdevices integrating affinity columns and capillary electrophoresis for multi-biomarker analysis in human serum

    PubMed Central

    Yang, Weichun; Yu, Ming; Sun, Xiuhua; Woolley, Adam T.

    2010-01-01

    Summary Biomarkers in human body fluids have great potential for use in screening for diseases such as cancer and diabetes, diagnosis, determining the effectiveness of treatments, and detecting recurrence. Present 96-well immunoassay technology effectively analyzes large numbers of samples; however, this approach is more expensive and less time effective on single or a few samples. In contrast, microfluidic systems are well suited for assaying small numbers of specimens in a point-of-care setting, provided suitable procedures are developed to work within peak capacity constraints when analyzing complex mixtures like human blood serum. Here, we developed integrated microdevices with an affinity column and capillary electrophoresis channels to isolate and quantitate a panel of proteins in complex matrices. To form an affinity column, a thin film of a reactive polymer was photopolymerized in a microchannel, and four antibodies were covalently immobilized to it. The retained protein amounts were consistent from chip to chip, demonstrating reproducibility. Furthermore, the signals from four fluorescently labeled proteins captured on-column were in the same range after rinsing, indicating the column has little bias toward any of the four antibodies or their antigens. These affinity columns have been integrated with capillary electrophoresis separation, enabling us to simultaneously quantify four protein biomarkers in human blood serum in the low ng/mL range using either a calibration curve or standard addition. Our systems provide a fast, integrated and automated platform for multiple biomarker quantitation in complex media such as human blood serum. PMID:20664867

  14. Group type analysis of asphalt by column liquid chromatography

    SciTech Connect

    Zhang, C.; Yang, J.; Xue, Y.; Li, Y.

    2008-07-01

    An improved analysis method for characterization of asphalt was established. The method is based on column chromatography technique. The asphalts were separated into four groups: saturates, aromatics, resins, and asphaltenes, quantitatively. About 0.1 g of sample was required in each analysis. About 20 mL of n-heptanes was used to separate out saturates first. Then about 35 mL of n-heptanes/dichloromethane (.5, v/v) mixture was used to separate out aromatics. About 30 mL of dichloromethane/tetrahydrofuran (1/3, v/v) mixture was used to separate out resin. The quality of the separation was confirmed by infrared spectra (IR) and {sup 1}H NMR analysis. The model compounds, tetracosan for saturates, dibenz(o)anthracen for aromatics, and acetanilide for resins were used for verification. The IR and {sup 1}H NMR analysis of the prepared fractions from the column liquid chromatography were in good agreement that of pure reagents.

  15. Purification of human copper, zinc superoxide dismutase by copper chelate affinity chromatography

    SciTech Connect

    Weslake, R.J.; Chesney, S.L.; Petkau, A.; Friesen, A.D.

    1986-05-15

    Copper, zinc superoxide dismutase was isolated from human red blood cell hemolysate by DEAE-Sepharose and copper chelate affinity chromatography. Enzyme preparations had specific activities ranging from 3400 to 3800 U/mg and recoveries were approximately 60% of the enzyme activity in the lysate. Copper chelate affinity chromatography resulted in a purification factor of about 60-fold. The homogeneity of the superoxide dismutase preparation was analyzed by sodium dodecyl sulfate-gel electrophoresis, analytical gel filtration chromatography, and isoelectric focusing.

  16. Methodology for optimally sized centrifugal partition chromatography columns.

    PubMed

    Chollet, Sébastien; Marchal, Luc; Jérémy Meucci; Renault, Jean-Hugues; Legrand, Jack; Foucault, Alain

    2015-04-03

    Centrifugal Partition Chromatography (CPC) is a separation process based on the partitioning of solutes between two partially miscible liquid phases. There is no solid support for the stationary phase. The centrifugal acceleration is responsible for both stationary phase retention and mobile phase dispersion. CPC is thus a process based on liquid-liquid mass transfer. The separation efficiency is mainly influenced by the hydrodynamics of the phases in each cell of the column. Thanks to a visualization system, called "Visual CPC", it was observed that the mobile phase can flow through the stationary phase as a sheet, or a spray. Hydrodynamics, which directly governs the instrument efficiency, is directly affected during scale changes, and non-linear phenomena prevent the successful achievement of mastered geometrical scale changes. In this work, a methodology for CPC column sizing is proposed, based on the characterization of the efficiency of advanced cell shapes, taking into account the hydrodynamics. Knowledge about relationship between stationary phase volume, cell efficiency and separation resolution in CPC allowed calculating the optimum cell number for laboratory and industrial scale CPC application. The methodology is highlighted with results on five different geometries from 25 to 5000 mL, for two applications: the separation of alkylbenzene by partitioning with heptane/methanol/water biphasic system; and the separation of peptides by partitioning with n-butanol/acetic acid/water (4/1/5) biphasic system. With this approach, it is possible to predict the optimal CPC column length leading to highest productivity.

  17. Column selectivity in reversed-phase liquid chromatography. VI. Columns with embedded or end-capping polar groups.

    PubMed

    Wilson, N S; Gilroy, J; Dolan, J W; Snyder, L R

    2004-02-13

    A previous model of column selectivity for reversed-phase liquid chromatography (RP-LC) has been applied to an additional 21 columns with embedded or end-capping polar groups (EPGs). Embedded-polar-group columns exhibit a significantly different selectivity vs. non-EPG, type-B columns, generally showing preferential retention of hydrogen-bond donors, as well as decreased retention for hydrogen-bond acceptors or ionized bases. EPG-columns are also generally less hydrophobic (more polar) than are non-EPG-columns. Interestingly, columns with polar end-capping tend to more closely resemble non-EPG columns, suggesting that the polar group has less effect on column selectivity when used to end-cap the column versus the case of an embedded polar group. Column selectivity data reported here for EPG-columns can be combined with previously reported values for non-EPG columns to provide a database of 154 different columns. This enables a comparison of any two of these columns in terms of selectivity. However, comparisons that involve EPG columns are more approximate.

  18. Optimization and simulation of tandem column supercritical fluid chromatography separations using column back pressure as a unique parameter.

    PubMed

    Wang, Chunlei; Tymiak, Adrienne A; Zhang, Yingru

    2014-04-15

    Tandem column supercritical fluid chromatography (SFC) has demonstrated to be a useful technique to resolve complex mixtures by serially coupling two columns of different selectivity. The overall selectivity of a tandem column separation is the retention time weighted average of selectivity from each coupled column. Currently, the method development merely relies on extensive screenings and is often a hit-or-miss process. No attention is paid to independently adjust retention and selectivity contributions from individual columns. In this study, we show how tandem column SFC selectivity can be optimized by changing relative dimensions (length or inner diameter) of the coupled columns. Moreover, we apply column back pressure as a unique parameter for SFC optimization. Continuous tuning of tandem column SFC selectivity is illustrated through column back pressure adjustments of the upstream column, for the first time. In addition, we show how and why changing coupling order of the columns can produce dramatically different separations. Using the empirical mathematical equation derived in our previous study, we also demonstrate a simulation of tandem column separations based on a single retention time measurement on each column. The simulation compares well with experimental results and correctly predicts column order and back pressure effects on the separations. Finally, considerations on instrument and column hardware requirements are discussed.

  19. Refolding and simultaneous purification of recombinant human proinsulin from inclusion bodies on protein-folding liquid-chromatography columns.

    PubMed

    Yuan, Jie; Zhou, Huifang; Yang, Yicong; Li, Weimin; Wan, Yi; Wang, Lili

    2015-05-01

    Protein-folding liquid chromatography (PFLC) is an effective and scalable method for protein renaturation with simultaneous purification. However, it has been a challenge to fully refold inclusion bodies in a PFLC column. In this work, refolding with simultaneous purification of recombinant human proinsulin (rhPI) from inclusion bodies from Escherichia coli were investigated using the surface of stationary phases in immobilized metal ion affinity chromatography (IMAC) and high-performance size-exclusion chromatography (HPSEC). The results indicated that both the ligand structure on the surface of the stationary phase and the composition of the mobile phase (elution buffer) influenced refolding of rhPI. Under optimized chromatographic conditions, the mass recoveries of IMAC column and HPSEC column were 77.8 and 56.8% with purifies of 97.6 and 93.7%, respectively. These results also indicated that the IMAC column fails to refold rhPI, and the HPSEC column enables efficient refolding of rhPI with a low-urea gradient-elution method. The refolded rhPI was characterized by circular dichroism spectroscopy. The molecular weight of the converted human insulin was further confirmed with SDS-18% PAGE, Matrix-Assisted Laser Desorption/ Ionization Time of Flight Mass Spectrometry (MALDI-TOF-MS) and the biological activity assay by HP-RPLC.

  20. Modeling on-column reduction of trisulfide bonds in monoclonal antibodies during protein A chromatography.

    PubMed

    Ghose, Sanchayita; Rajshekaran, Rupshika; Labanca, Marisa; Conley, Lynn

    2017-01-06

    Trisulfides can be a common post-translational modification in many recombinant monoclonal antibodies. These are a source of product heterogeneity that add to the complexity of product characterization and hence, need to be reduced for consistent product quality. Trisulfide bonds can be converted to the regular disulfide bonds by incorporating a novel cysteine wash step during Protein A affinity chromatography. An empirical model is developed for this on-column reduction reaction to compare the reaction rates as a function of typical operating parameters such as temperature, cysteine concentration, reaction time and starting level of trisulfides. The model presented here is anticipated to assist in the development of optimal wash conditions for the Protein A step to effectively reduce trisulfides to desired levels.

  1. [Preparation and evaluation of pepsin affinity organic polymer capillary monolithic column].

    PubMed

    Chi, Cuijie; Wang, Wei; Ji, Yibing

    2014-08-01

    The protein modified monolithic column in affinity capillary electrochromatography (CEC) has attracted considerable attention over the past decades because of its great enantioseparation ability. A porous polymethacrylate ester-based capillary monolithic column poly (glycidyl methacrylate-co-ethyleneglycol dimethacrylate) (poly (GMA-co-EDMA)) was prepared by in situ co-polymerization. The process was initiated thermally by azobisisobutyronitrile (AIBN). The polymerization mixture contained GMA as the function monomer and EDMA as the crosslinking agent with 1,4-butanediol and 1-propanol as the binary porogen solvent. Under the optimized reaction conditions, including the proportion of monomer and porogens, reaction temperature etc, the column exhibited a uniform structure, sufficient permeability and excel- lent pressure resistance. The separation of alkyl benzenes on the column was mainly based on typical reversed-phase chromatographic retention mechanism. The reproducibility and stability were good with RSDs less than 9. 0%. A pepsin functionalized organic polymer monolith was prepared by covalently bonded pepsin to poly(GMA-co-EDMA) monolith with glutaraldehyde as a spacer based on the activity of epoxide group. The enantioseparation performance of the pepsin affinity monolith for basic enantiomers has been investigated by CEC. Nefopam, amlodipine, citalopram and chlorpheniramine were resolved, and baseline separations of nefopam, amlodipine, citalopram were achieved. The influences of pH, operating voltage, temperature and sample quantity used on the chiral separation were studied. The chiral recognition mechanism of enantiomers on the monolithic column in CEC is discussed. This work developed a new method for the prepataion and application of protein affinity monolith in CEC.

  2. Isolation of Three Components from Spearmint Oil: An Exercise in Column and Thin-Layer Chromatography

    ERIC Educational Resources Information Center

    Davies, Don R.; Johnson, Todd M.

    2007-01-01

    A simple experiment for undergraduate organic chemistry students to separate a colorless mixture using column chromatography and then monitor the outcome of the separation using thin-layer chromatography (TLC) and infrared spectroscopy(IR) is described. The experiment teaches students the principle and techniques of column and thin-layer…

  3. Efficient endotoxin removal with a new sanitizable affinity column: Affi-Prep Polymyxin.

    PubMed

    Talmadge, K W; Siebert, C J

    1989-08-04

    A new affinity column packing for removal of endotoxins has been prepared by coupling USP drug-quality polymyxin B to Affi-Prep, a novel synthetic macroporous polymer. Affi-Prep Polymyxin binds endotoxins from a number of different strains of gram-negative bacteria. Endotoxin binding is not significantly affected by 10 mg/ml of bovine serum albumin or human immunoglobulin G, by 1 mg/ml sodium dodecyl sulphate, or by 1 mg/ml deoxycholate. Affi-Prep Polymyxin is stable to treatment with 1.0 M sodium hydroxide, an important property for sanitizing the resin. The resin shows a high ligand stability, since no leakage of polymyxin B from the packing could be detected. Affi-Prep Polymyxin exhibited the highest endotoxin binding efficiency when compared with several commercial agarose affinity packings.

  4. PDZ Affinity Chromatography: A general method for affinity purification of proteins based on PDZ domains and their ligands

    PubMed Central

    Walkup, Ward G.; Kennedy, Mary B.

    2014-01-01

    PDZ (PSD-95, DiscsLarge, ZO1) domains function in nature as protein binding domains within scaffold and membrane-associated proteins. They comprise ~ 90 residues and make specific, high affinity interactions with complementary C-terminal peptide sequences, with other PDZ domains, and with phospholipids. We hypothesized that the specific, strong interactions of PDZ domains with their ligands would make them well suited for use in affinity chromatography. Here we describe a novel affinity chromatography method applicable for the purification of proteins that contain PDZ domain-binding ligands, either naturally or introduced by genetic engineering. We created a series of affinity resins comprised of PDZ domains from the scaffold protein PSD-95, or from neuronal nitric oxide synthase (nNOS), coupled to solid supports. We used them to purify heterologously expressed neuronal proteins or protein domains containing endogenous PDZ domain ligands, eluting the proteins with free PDZ domain peptide ligands. We show that Proteins of Interest (POIs) lacking endogenous PDZ domain ligands can be engineered as fusion products containing C-terminal PDZ domain ligand peptides or internal, N- or C-terminal PDZ domains and then can be purified by the same method. Using this method, we recovered recombinant GFP fused to a PDZ-domain ligand in active form as verified by fluorescence yield. Similarly, chloramphenicol acetyltransferase (CAT) and β-Galactosidase (LacZ) fused to a C-terminal PDZ domain ligand or an N-terminal PDZ domain were purified in active form as assessed by enzymatic assay. In general, PDZ domains and ligands derived from PSD-95 were superior to those from nNOS for this method. PDZ Domain Affinity Chromatography promises to be a versatile and effective method for purification of a wide variety of natural and recombinant proteins. PMID:24607360

  5. PDZ affinity chromatography: a general method for affinity purification of proteins based on PDZ domains and their ligands.

    PubMed

    Walkup, Ward G; Kennedy, Mary B

    2014-06-01

    PDZ (PSD-95, DiscsLarge, ZO1) domains function in nature as protein binding domains within scaffold and membrane-associated proteins. They comprise ∼90 residues and make specific, high affinity interactions with complementary C-terminal peptide sequences, with other PDZ domains, and with phospholipids. We hypothesized that the specific, strong interactions of PDZ domains with their ligands would make them well suited for use in affinity chromatography. Here we describe a novel affinity chromatography method applicable for the purification of proteins that contain PDZ domain-binding ligands, either naturally or introduced by genetic engineering. We created a series of affinity resins comprised of PDZ domains from the scaffold protein PSD-95, or from neuronal nitric oxide synthase (nNOS), coupled to solid supports. We used them to purify heterologously expressed neuronal proteins or protein domains containing endogenous PDZ domain ligands, eluting the proteins with free PDZ domain peptide ligands. We show that Proteins of Interest (POIs) lacking endogenous PDZ domain ligands can be engineered as fusion products containing C-terminal PDZ domain ligand peptides or internal, N- or C-terminal PDZ domains and then can be purified by the same method. Using this method, we recovered recombinant GFP fused to a PDZ domain ligand in active form as verified by fluorescence yield. Similarly, chloramphenicol acetyltransferase (CAT) and β-Galactosidase (LacZ) fused to a C-terminal PDZ domain ligand or an N-terminal PDZ domain were purified in active form as assessed by enzymatic assay. In general, PDZ domains and ligands derived from PSD-95 were superior to those from nNOS for this method. PDZ Domain Affinity Chromatography promises to be a versatile and effective method for purification of a wide variety of natural and recombinant proteins.

  6. Affinity Chromatography of Native and Recombinant Proteins from Receptors for Insulin and IGF-I to Recombinant Single Chain Antibodies

    PubMed Central

    Fujita-Yamaguchi, Yoko

    2015-01-01

    Affinity chromatography is an efficient method to isolate proteins by taking advantage of their affinities for specific molecules such as substrates, inhibitors, antigens, ligands, antibodies, and other interacting molecules, including subunits. Nowadays, we take the effectiveness and excellence of this technology for granted. This essay will mainly cover the use of affinity chromatography based on my experience. PMID:26579073

  7. Identification of hepatic copper-binding proteins from tilapia by column chromatography with proteomic approaches.

    PubMed

    Chen, Dongshi; Chan, King Ming

    2012-08-01

    Although copper is an essential element, it shows cytotoxic effects when present in excessive amounts with the production of hydroxyl radicals, which can damage phospholipids and enzymes. This necessitates a tight cellular control mechanism for copper homeostasis including its uptake and removal. The high copper contents in the liver of tilapia make this fish a suitable model for the study of copper binding proteins (CBPs). The liver was dissected from tilapia injected with Cu(2+) and cytosolic fractions were separated by using Superdex 75 column chromatography followed by atomic absorption spectrometry. Fractions in two major peaks containing CBPs were analyzed by using differential proteomic approaches, and loaded on a Cu chelating ion-immobilized affinity column (Cu-IMAC). Of the 113 differentially expressed proteins in these two peaks, 28 proteins were found to have copper binding ability, including well-characterized CBPs, such as copper transporter ATP7A and metallothionein. The networks of CBPs built up by Ingenuity Pathway Analysis (IPA) would help us to understand the transportation pathway and function of CBPs, which were related to free radical scavenging, cellular development and lipid metabolism. In addition, our results suggest that Cu(2+) would compete with Fe(2+) and Ca(2+) in binding with some target proteins, such as ferritin, transferrin, and calmodulin.

  8. Purification and characterization of a Cytisus-type Ulex europeus hemagglutinin II by affinity chromatography.

    PubMed

    Konami, Y; Tsuji, T; Matsumoto, I; Osawa, T

    1981-07-01

    Ulex europeus hemagglutinin II [Cytisus-type anti-H(O) hemagglutinin] inhibited most by di-N-acetylchitobiose has been purified by affinity chromatography on a column of chitobiose-Sepharose 4B, followed by gel filtration on Sephacryl S-300. The purified hemagglutinin was homogeneous by ultracentrifugal analysis and gave a single band by electrophoresis on polyacrylamide gel, and had a molecular weight of 105 000 by sedimentation equilibrium and an isoelectric point of pH 6.66. This hemagglutinin was found to be composed of four, apparently identical, subunits of a molecular weight of 25 000 +/- 2 000 by dodecyl sulphate-polyacrylamide gel electrophoresis, and to contain 10.3% carbohydrate in which mannose (3.7%) was the predominant sugar, with smaller amounts of glucose, glucosamine, xylose, fucose and galactose. Amino acid analysis of the purified hemagglutinin II showed a large amount of aspartic acid and serine, but as little as 0.1 mol/100 mol of cystine or methionine could be detected.

  9. CHARACTERIZATION OF DRUG INTERACTIONS WITH SERUM PROTEINS BY USING HIGH-PERFORMANCE AFFINITY CHROMATOGRAPHY

    PubMed Central

    Hage, David S.; Anguizola, Jeanethe; Barnaby, Omar; Jackson, Abby; Yoo, Michelle J.; Papastavros, Efthimia; Pfaunmiller, Erika; Sobansky, Matt; Tong, Zenghan

    2011-01-01

    The binding of drugs with serum proteins can affect the activity, distribution, rate of excretion, and toxicity of pharmaceutical agents in the body. One tool that can be used to quickly analyze and characterize these interactions is high-performance affinity chromatography (HPAC). This review shows how HPAC can be used to study drug-protein binding and describes the various applications of this approach when examining drug interactions with serum proteins. Methods for determining binding constants, characterizing binding sites, examining drug-drug interactions, and studying drug-protein dissociation rates will be discussed. Applications that illustrate the use of HPAC with serum binding agents such as human serum albumin, α1-acid glycoprotein, and lipoproteins will be presented. Recent developments will also be examined, such as new methods for immobilizing serum proteins in HPAC columns, the utilization of HPAC as a tool in personalized medicine, and HPAC methods for the high-throughput screening and characterization of drug-protein binding. PMID:21395530

  10. Characterization of minor site probes for human serum albumin by high-performance affinity chromatography.

    PubMed

    Sengupta, A; Hage, D S

    1999-09-01

    This study used high-performance affinity chromatography (HPAC) and immobilized human serum albumin (HSA) columns to examine the specificity and cross-reactivity of various compounds that have been proposed as markers for the minor binding sites of HSA. These agents included acetyldigitoxin and digitoxin as probes for the digitoxin site, phenol red as a probe for the bilirubin site, and cisor trans-clomiphene as markers for the tamoxifen site. None of these probes showed any significant binding at HSA's indole-benzodiazepine site. However, phenol red did bind at the warfarin-azapropazone site of HSA, and cis/trans-clomiphene gave positive allosteric effects caused by the binding of warfarin to HSA. Digitoxin and acetyldigitoxin were found to bind to a common, unique region on HSA; cis- and trans-clomiphene also appeared to interact at a unique site, although trans-clomiphene displayed additional direct competition with phenol red. From these results it was possible to develop a model that described the general relationship between these binding regions on HSA. This information should be useful in future studies that employ HPAC for characterizing the binding of HSA to other drugs or clinical agents.

  11. Determination of the kinetic rate constant of cyclodextrin supramolecular systems by high performance affinity chromatography.

    PubMed

    Li, Haiyan; Ge, Jingwen; Guo, Tao; Yang, Shuo; He, Zhonggui; York, Peter; Sun, Lixin; Xu, Xu; Zhang, Jiwen

    2013-08-30

    It is challenging and extremely difficult to measure the kinetics of supramolecular systems with extensive, weak binding (Ka<10(5)M(-1)), and fast dissociation, such as those composed of cyclodextrins and drugs. In this study, a modified peak profiling method based on high performance affinity chromatography (HPAC) was established to determine the dissociation rate constant of cyclodextrin supramolecular systems. The interactions of β-cyclodextrin with acetaminophen and sertraline were used to exemplify the method. The retention times, variances and the plate heights of the peaks for acetaminophen or sertraline, conventional non-retained substance (H2O) on the β-cyclodextrin bonded column and a control column were determined at four flow rates under linear elution conditions. Then, plate heights for the theoretical non-retained substance were estimated by the modified HPAC method, in consideration of the diffusion and stagnant mobile phase mass transfer. As a result, apparent dissociation rate constants of 1.82 (±0.01)s(-1) and 3.55 (±0.37)s(-1) were estimated for acetaminophen and sertraline respectively at pH 6.8 and 25°C with multiple flow rates. Following subtraction of the non-specific binding with the support, dissociation rate constants were estimated as 1.78 (±0.00) and 1.91 (±0.02)s(-1) for acetaminophen and sertraline, respectively. These results for acetaminophen and sertraline were in good agreement with the magnitude of the rate constants for other drugs determined by capillary electrophoresis reported in the literature and the peak fitting method we performed. The method described in this work is thought to be suitable for other supramolecules, with relatively weak, fast and extensive interactions.

  12. Mullerian inhibiting substance fractionation by dye affinity chromatography.

    PubMed

    Budzik, G P; Powell, S M; Kamagata, S; Donahoe, P K

    1983-08-01

    Mullerian inhibiting substance (MIS), a large glycoprotein secreted by the fetal and neonatal testis, is responsible for regression of the Mullerian ducts in the male embryo. This fetal growth regulator has been purified more than 2000-fold from crude testicular incubation medium following fractionation on a triazinyl dye affinity support. A high yield of 60% recovered activity was achieved in the absence of exogenous carrier protein by stabilizing MIS with 2-mercaptoethanol, EDTA, and Nonidet-P40 and eliminating losses in the handling and concentration of MIS fractions. Although affinity elution with nucleotides has proved successful in other systems, MIS could not be eluted with ATP, GTP, or AMP, with or without divalent metal ions. Nucleotide elution, however, does remove contaminating proteins prior to MIS recovery with high ionic strength. The 2000-fold-purified MIS fraction, although not homogeneous, shows a reduction-sensitive band after SDS-gel electrophoresis that has been proposed to be the MIS dimer.

  13. Halo columns: new generation technology for high speed liquid chromatography.

    PubMed

    Ali, Imran; Gaitonde, Vinay D; Grahn, Anders

    2010-01-01

    Fast speed and high sample loading and the pressing demands of industries and researchers are compelling scientists and manufacturers to explore the new horizons in column technology. Recently, superficially porous silica particle columns are manufactured with some salient features such as super fast speed, sharp peaks, good sample loading, and low backpressure. The commercially available columns are Halo (Advanced Material Technology, Wilmington, DE), Express (Supelco, Bellefonte, PA), and Proshell 120 (Agilent, Santa Clara, CA). Halo columns are of C(8), C(18), RP Amide, and HILIC types with 2.7 microm over all diameters, 0.5 microm porous thick layers containing 90 A as pore diameter, and 150 m(2)/g surface area. These columns have been used for fast separation of low molecular weight compounds with some exception for large molecules such as protein, peptides, and DNA. The present article describes the importance of these state-of-the-art superficially porous silica particles based columns with special emphasis on Halo columns. The different aspects of these columns such as structures, mechanism of separations, applications, and comparison, with conventional columns have been discussed.

  14. Mixed-bed affinity chromatography: principles and methods.

    PubMed

    Boschetti, Egisto; Righetti, Pier Giorgio

    2015-01-01

    Mixed-bed chromatography is far from being a well-established technology within the panoply of bioseparation tools. Composed of an assembly of distinct sorbents that are mixed in a single bed, they have been mostly developed in the last decade for the reduction of dynamic concentration range where they allowed discovering many low-copy proteins within very complex proteomes. Other interesting preparative applications of mixed-bed chromatography have since been developed. In this chapter the basic concepts first and then detailed application recipes are described for (1) the reduction of protein dynamic concentration range, (2) the removal of impurity traces at the last stage of a biopurification process, and (3) the selection and use of sorbents as mixed bed in protein purification.

  15. Planar gas chromatography column on aluminum plate with multi-walled carbon nanotubes as stationary phase

    NASA Astrophysics Data System (ADS)

    Platonov, I. A.; Platonov, V. I.; Pavelyev, V. S.

    2016-04-01

    The high selectivity of the adsorption layer for low-boiling alkanes is shown, the separation factor (α) couple iso-butane / butane is 1.9 at a column temperature of 50 °C.The paper presents sorption and selective properties of planar gas chromatography column on aluminum plate with multi-walled carbon nanotubes as the stationary phase.

  16. Colorful Column Chromatography: A Classroom Demonstration of a Three-Component Separation

    ERIC Educational Resources Information Center

    Heumann, Lars V.

    2008-01-01

    A classroom demonstration detailing the procedure for the separation of a ternary mixture consisting of intensely colored compounds using silica gel column chromatography is described. The audience can follow the compounds during their passage through the column as individual, colored bands while learning about different tools and techniques used…

  17. Evaluation of SDS depletion using an affinity spin column and IMS-MS detection

    SciTech Connect

    Hengel, Shawna M.; Floyd, Erica A.; Baker, Erin Shammel; Zhao, Rui; Wu, Si; Pasa-Tolic, Ljiljana

    2012-11-01

    While the use of detergents is necessary for a variety of protein isolation preparation protocols, often prior to mass spectral (MS) analysis, they are not compatible with MS analysis due to ion suppression and adduct formation. This manuscript describes optimization of detergent removal, using commercially available SDS depletion spin columns containing an affinity resin, providing for both increased protein recovery and thorough SDS removal. Ion mobility spectrometry coupled with mass spectrometry (IMS-MS) allowed for a concurrent analysis of both analyte and detergent. In the case of both proteins and peptides, higher detergent concentrations than previously reported provided an increase of sample recovery; however there was a limit as SDS was detected by IMS-MS at higher levels of SDS indicating incomplete detergent depletion. The results also suggest optimal conditions for SDS removal are dependent on the sample concentration. Overall, this study provides a useful guide for proteomic studies where SDS is required for efficient sample preparation.

  18. Stationary phase modulation in liquid chromatography through the serial coupling of columns: A review.

    PubMed

    Alvarez-Segura, T; Torres-Lapasió, J R; Ortiz-Bolsico, C; García-Alvarez-Coque, M C

    2016-06-07

    Liquid chromatography with single columns often does not succeed in the analysis of complex samples, in terms of resolution and analysis time. A relatively simple solution to enhance chromatographic resolution is the modulation of the stationary phase through the serial coupling of columns. This can be implemented with any type of column using compatible elution conditions and conventional instruments. This review describes the key features of column coupling and published procedures, where two or more columns were coupled in series to solve separation problems. In all reports, the authors could not resolve their samples with single columns, whereas significant enhancement in chromatographic performance was obtained when the columns were combined. Particularly interesting is the reduction in the analysis time in the isocratic mode, which alleviates the "general elution problem" of liquid chromatography, and may represent a stimulus for the proposal of new procedures, especially in combination with mass spectrometric, electrochemical and refractometric detection. Developments proposed to make the serial coupling of columns useful in routine and research laboratories are outlined, including optimisation strategies that facilitate the selection of the appropriate column combination and elution conditions (solvent content, flow rate or temperature) in both isocratic and gradient modes. The availability of zero dead volume couplers, able to connect standard columns, and the commercialisation of short columns with multiple lengths, have expanded the possibilities of success.

  19. Separation of donor and recipient bacteria by column chromatography.

    PubMed

    Zsigray, R M; Fulk, G E; Lawton, W D

    1970-08-01

    When donor and recipient strains of Escherichia coli were added to columns containing Cellex-P (a cation-exchange cellulose), more than 80% of the female cells passed through the column but only 11% or less of the male cells were eluted. However, when donor strains were blended before their addition to the column, the majority of these cells were eluted. These results indicated that the filamentous appendages termed F pili (which are removed by blending) were the structures responsible for the adherence of donor cells to the cellulose.

  20. Application of coupled affinity-sizing chromatography for the detection of proteolyzed HSA-tagged proteins.

    PubMed

    London, Anne Serdakowski; Patel, Kunal; Quinn, Lisa; Lemmerer, Martin

    2015-04-01

    Coupled affinity liquid chromatography and size exclusion chromatography (ALC-SEC) is a technique that has been shown to successfully report product quality of proteins during cell expression and prior to the commencement of downstream processing chromatography steps. This method was applied to monitoring the degradation and subsequent partial remediation of a HSA-tagged protein which showed proteolysis, allowing for rapid cell line development to address this product quality dilemma. This paper outlines the novel application of this method for measuring and addressing protease-induced proteolysis.

  1. Adenovirus purification by two-column, size-exclusion, simulated countercurrent chromatography.

    PubMed

    Nestola, Piergiuseppe; Silva, Ricardo J S; Peixoto, Cristina; Alves, Paula M; Carrondo, Manuel J T; Mota, José P B

    2014-06-20

    Adenovirus serotype 5 (Ad5) was successfully separated by size-exclusion chromatography (SEC) using a simple, yet efficient, two-column, quasi-continuous, simulated moving-bed process operated in an open-loop configuration. The operating cycle is divided into two identical half-cycles, each of them consisting of the following sequence of sub-steps: (i) elution of the upstream column and direction of the effluent of the downstream column to waste; (ii) elution of the upstream column and redirection of its effluent to waste while the downstream column is fed with the clarified bioreaction bulk and its effluent collected as purified product; (iii) operation of the system as in step (i) but collecting the effluent of the downstream column as product; (iv) elution of the upstream column and direction of its effluent to waste while the flow through the downstream column is temporarily halted. Clearance of impurities, namely DNA and host cell protein (HCP), were experimentally assessed. The pilot-scale run yielded a virus recovery of 86%, and a clearance of 90% and 89% for DNA and HCP, respectively, without any fine tunning of the predetermined operating parameters. These figures compare very favorably against single-column batch chromatography for the same volume of size-exclusion resin. However, and most importantly, the virus yield was increased from 57% for the batch system to 86% for the two-column SEC process because of internal recycling of the mixed fractions of contaminated Ad5, even though the two-column process was operated strictly in an open-loop configuration. And last, but not least, the productivity was increased by 6-fold with the two-column process. In conclusion, the main drawbacks of size-exclusion chromatography, namely low productivity and low product titer, were overcome to a considerable extent by an innovative two-column configuration that keeps the mixed fractions inside the system at all times.

  2. Column selectivity in reversed-phase liquid chromatography. IV. Type-B alkyl-silica columns.

    PubMed

    Gilroy, Jonathan J; Dolan, John W; Snyder, Lloyd R

    2003-06-06

    Columns for reversed-phase HPLC (RP-LC) can be characterized by five, retention-related parameters: H (hydrophobicity), S (steric selectivity), A (hydrogen-bond acidity), B (hydrogen-bond basicity), and C (cation-exchange behavior). In the present study, values of the latter parameters have been measured for 92 type-B (low metals content)alkyl-silica columns and compared to column properties such as ligand length,ligand concentration, pore diameter, and the presence or absence of end-capping. With the exception of five columns of unusual design, retention factors, k, for 16 representative test compounds were correlated with values of H, S, etc., within an average +/- 1.2% (1 standard deviation, SD), suggesting that all significant solute-column interactions are recognized by these five column parameters. A single-valued function F(s) is proposed to measure differences in selectivity for any two RP-LC columns whose values of H, S, etc., are known. This allows the easy selection of columns whose selectivity is desired to be either similar to or different from a starting column, for application in either routine analysis or method development.

  3. Glycan-specific whole cell affinity chromatography: a versatile microbial adhesion platform

    Technology Transfer Automated Retrieval System (TEKTRAN)

    We have constructed a C-glycoside ketohydrazide affinity chromatography resin that interacts with viable whole-cell microbial populations with biologically appropriate stereo-specificity in a carbohydrate-defined manner. It readily allows for the quantification, selection, and manipulation of target...

  4. Generator for ionic gallium-68 based on column chromatography

    DOEpatents

    Neirinckx, Rudi D.; Davis, Michael A.

    1981-01-01

    A physiologically acceptable solution of gallium-68 fluorides, having an activity of 0.1 to 50 millicuries per milliliter of solution is provided. The solution is obtained from a generator comprising germanium-68 hexafluoride bound to a column of an anion exchange resin which forms gallium-68 in situ by eluting the column with an acid solution to form a solution containing .sup.68 Ga-fluorides. The solution then is neutralized prior to administration.

  5. Cross-linked leucaena seed gum matrix: an affinity chromatography tool for galactose-specific lectins.

    PubMed

    Seshagirirao, Kottapalli; Leelavathi, Chaganti; Sasidhar, Vemula

    2005-05-31

    A cross-linked leucaena (Leucaena leucocephala) seed gum (CLLSG) matrix was prepared for the isolation of galactose-specific lectins by affinity chromatography. The matrix was evaluated for affinity with a known galactose-specific lectin from the seeds of snake gourd (Trichosanthes anguina). The matrix preparation was simple and inexpensive when compared to commercial galactose-specific matrices (i.e. about 1.5 US dollars/100 ml of matrix). The current method is also useful for the demonstration of the affinity chromatography technique in laboratories. Since leucaena seeds are abundant and inexpensive, and the matrix preparation is easy, CLLSG appears to be a promising tool for the separation of galactose-specific lectins.

  6. Preparation and Characterization of a Polymeric Monolithic Column for Use in High-Performance Liquid Chromatography (HPLC)

    ERIC Educational Resources Information Center

    Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2011-01-01

    The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…

  7. Surface modification of polytetrafluoroethylene column for two-stationary phase separations by counter-current chromatography.

    PubMed

    Quan, Kai-jun; Huang, Xin-yi; Li, Xiao-ting; Wang, Gao-hong; Liu, Yan-juan; Duan, Wen-da; Di, Duo-long

    2015-11-27

    To improve the separation capability of CCC, a novel solid-liquid two-stationary phases CCC (ASP-CCC) column was prepared employing graphene oxide (GO) conjugated poly-dopamine (PD) coating (GO/PD) as auxiliary stationary phase (ASP). The results of Scanning electron microscopy (SEM), contact angle and X-ray photoelectron spectroscopy (XPS) indicated that nanostructured GO and PD were successfully grafted on the inner wall of the PTFE column. Three alkaloid compounds were selected as the target analytes to evaluate the performance of the novel column. Because of the intermolecular force (hydrogen bond, electrostatic interaction and π-π interaction) between the ASP and model compounds, three analytes were well separated with this novel ASP-CCC column. Additionally, the novel column exhibited higher stationary phase retention ratio, about 8%, than original column without changing the chromatographic condition. Furthermore, the eluotropic sequence of analytes on novel column was in accordance with that in the original column. This suggested that the novel column is a CCC column with auxiliary stationary phase (ASP) in its own right, and the present separation mode is the combination of partition chromatography and adsorption chromatography.

  8. Sum of ranking differences to rank stationary phases used in packed column supercritical fluid chromatography.

    PubMed

    West, Caroline; Khalikova, Maria A; Lesellier, Eric; Héberger, Károly

    2015-08-28

    The identification of a suitable stationary phase in supercritical fluid chromatography (SFC) is a major source of difficulty for those with little experience in this technique. Several protocols have been suggested for column classification in high-performance liquid chromatography (HPLC), gas chromatography (GC), and SFC. However, none of the proposed classification schemes received general acceptance. A fair way to compare columns was proposed with the sum of ranking differences (SRD). In this project, we used the retention data obtained for 86 test compounds with varied polarity and structure, analyzed on 71 different stationary phases encompassing the full range in polarity of commercial packed columns currently available to the SFC chromatographer, with a single set of mobile phase and operating conditions (carbon dioxide-methanol mobile phase, 25°C, 150bar outlet pressure, 3ml/min). First, a reference column was selected and the 70 remaining columns were ranked based on this reference column and the retention data obtained on the 86 analytes. As these analytes previously served for the calculation of linear solvation energy relationships (LSER) on the 71 columns, SRD ranks were compared to LSER methodology. Finally, an external comparison based on the analysis of 10 other analytes (UV filters) related the observed selectivity to SRD ranking. Comparison of elution orders of the UV filters to the SRD rankings is highly supportive of the adequacy of SRD methodology to select similar and dissimilar columns.

  9. Devising an adjustable splitter for dual-column gas chromatography.

    PubMed

    Wang, Chieh-Heng; Chang, Chih-Chung; Wang, Jia-Lin

    2007-09-07

    A flow controlled adjustable splitter was configured from a Deans switch and employed in an automated dual column gas chromatographic (GC) system for analyzing mono-aromatic compounds. Volatile organic compounds (VOCs), thermally desorbed from the sorbent trap, were split by the adjustable splitter onto two columns of different phases for separation and then detection by flame ionization detection (FID). Unlike regular splitters in which the split ratio is passively determined by the diameter and/or length of the connecting columns or tubing, the split ratio in our adjustable splitter is controlled by the auxiliary flow in the Deans switch. The auxiliary flow serves as a gas plug on either side of the column for decreasing the sample flow in one transfer line, but increasing the flow in the other. By adjusting the auxiliary flow and therefore the size of the gas plug, the split ratio can be easily varied and favorable to the side of no auxiliary gas. As an illustration, two columns, DB-1 and Cyclodex-B, were employed in this study for separating benzene, toluene, ethylbenzene, xylenes, denoted as BTEX, in particular the structural isomers of o-, m-, p-xylenes. This configuration demonstrates that BTEX cannot be fully separated with either column, but can be deconvoluted by simple algebra if dual columns are used with a splitter. The applicability of the proposed concept was tested by analyzing a gas standard containing BTEX at different split ratios and with various sample sizes, all leading to a constant ratio of m-xylene versus p-xylene.

  10. Orthogonal separation on one beta-cyclodextrin column by switching reversed-phase liquid chromatography and hydrophilic interaction chromatography.

    PubMed

    Feng, Jia-tao; Guo, Zhi-mou; Shi, Hui; Gu, Jiang-ping; Jin, Yu; Liang, Xin-miao

    2010-06-15

    A dual retention combined with reversed-phase liquid chromatography (RP-LC) and hydrophilic interaction chromatography (HILIC) has been observed on beta-cyclodextrin (beta-CD) bonded stationary phase. A typical U-shaped retention curve was achieved owing to dual retention mechanism. Based on this observation, a beta-CD column can be operated under reversed-phase liquid chromatography (RP-LC) and hydrophilic interaction chromatography (HILIC) modes. Two-dimensional liquid chromatography (2D-LC) analysis can be realized on just a beta-CD column by switching these two different separation modes. In this study, off-line 2D-LC analysis for a natural product was carried out to prove the orthogonal separation between RP-LC and HILIC modes on a Click beta-CD column. Herba Hedyotis Diffusae, the whole grass of Hedyotis Diffusae wild was extracted with water, pretreated with macroporous resin and then first separated at RP-LC mode on the Click beta-CD column to obtain successive fractions, which were then reanalyzed at HILIC mode on the same Click beta-CD column. The result proved that both separation modes on the Click beta-CD column have good retention and peak shape, and these two separation modes have good orthogonality. 2D-LC analysis revealed abundant information in the natural product. Especially numerous minor components were enriched and separated. The mobile phase used in RP-LC and HILIC modes can be same and the switch between these two separation modes is easily realized by changing the ratio of the acetonitrile and water. Hence the mobile phase in this 2D-LC system is completely compatible. This advantage makes this combination is an appropriate 2D-LC method for the solutes having retention at both separation modes.

  11. Purification and characterization of two types of Cytisus multiflorus hemagglutinin by affinity chromatography.

    PubMed

    Konami, Y; Yamamoto, K; Tsuji, T; Matsumoto, I; Osawa, T

    1983-10-01

    Two hemagglutinins were separated from extracts of Cytisus multiflorus seeds by successive affinity chromatographies on columns of galactose- and di- N-acetylchitobiose-Sepharose 4B. One was found to be inhibited by di- N-acetylchitobiose or tri- N-acetylchitotriose and shown to possess anti-H(O) activity [Cytisus-type anti-H(O) hemagglutinin designated as Cytisus multiflorus hemagglutinin I]. The other, which was not a blood group-specific hemagglutinin, was inhibited by galactose or lactose (hemagglutinin II). Hemagglutinins I and II were further purified by gel filtration on Sephacryl S-300. These preparations were homogeneous as judged by polyacrylamide gel electrophoresis and gel filtration. The molecular weights of the purified hemagglutinins I and II were found to be 86000 by sedimentation equilibrium analysis and 80000 by gel filtration. On disc gel electrophoresis in the presence of sodium dodecyl sulfate and dithiothreitol, both hemagglutinins gave a single component of a molecular weight of 42000 +/- 2000, suggesting that these hemagglutinins are dimeric proteins of two identical subunits. Hemagglutinins I and II contain 2.7% and 1.5% carbohydrate, respectively, and only very small amounts of cystine and methionine were detected, but they are rich in aspartic acid and serine. Treatment of human O erythrocytes with a purified H-decomposing enzyme (alpha-L-fucosidase from Bacillus fulminans abolished the agglutinability of the cells with hemagglutinin I. This indicates that the L-fucosyl residue is important even for the H-specificity detected by this di-N-acetylchitobiose-specific hemagglutinin I.

  12. Purification of antibodies against N-homocysteinylated proteins by affinity chromatography on Nomega-homocysteinyl-aminohexyl-Agarose.

    PubMed

    Perła, Joanna; Undas, Anetta; Twardowski, Tomasz; Jakubowski, Hieronim

    2004-08-05

    Modification with homocysteine (Hcy)-thiolactone leads to the formation of N-Hcy-Lys-protein. Although N-Hcy-Lys-proteins are immunogenic, pure antibodies have not yet been obtained. Here we describe synthesis and application of Nomega-homocysteinyl-aminohexyl-Agarose for affinity purification of anti-N-Hcy-Lys-protein antibodies. Nomega-homocysteinyl-aminohexyl-Agarose was prepared by N-homocysteinylation of omega-aminohexyl-Agarose with Hcy-thiolactone. Immune serum was obtained from rabbits inoculated with N-Hcy-Lys-keyhole limpet hemocyanine and IgG fraction prepared by chromatography on protein A-Agarose. Anti-N-Hcy-Lys-protein IgG was adsorbed on Nomega-homocysteinyl-aminohexyl-Agarose column at pH 8.6 and eluted with a pH 2.3 buffer. Enzyme-linked immunosorbent assays demonstrate that the antibody recognizes specifically N-homocysteinylated variants of hemoglobin, albumin, transferrin, and antitrypsin.

  13. A straightforward methodology for designing continuous monoclonal antibody capture multi-column chromatography processes.

    PubMed

    Gjoka, Xhorxhi; Rogler, Karl; Martino, Richard Alexander; Gantier, Rene; Schofield, Mark

    2015-10-16

    A simple process development strategy for continuous capture multi-column chromatography (MCC) is described. The approach involves a few single column breakthrough experiments, based on several simplifying observations that enable users to rapidly convert batch processes into well-designed multi-column processes. The method was validated using a BioSMB(®) (Pall Life Sciences) lab scale multi-column system and a mAb capture process employing Protein A resin. The approach enables users to optimize MCC processes based on their internal preferences and constraints without requiring any mathematical modeling expertise.

  14. Affinity chromatography approaches to overcome the challenges of purifying plasmid DNA.

    PubMed

    Sousa, Fani; Prazeres, Duarte M F; Queiroz, João A

    2008-09-01

    The diversity of biomolecules present in plasmid DNA (pDNA)-containing extracts and the structural and chemical similarities between pDNA and impurities are some of the main challenges of improving or establishing novel purification procedures. In view of the unequalled specificity of affinity purification, this technique has recently begun to be applied in downstream processing of plasmids. This paper discusses the progress and importance of affinity chromatography (AC) for the purification of pDNA-based therapeutic products. Several affinity approaches have already been successfully developed for a variety of applications, and we will focus here on highlighting their possible contributions to the pDNA purification challenge. Diverse affinity applications and their advantages and disadvantages are discussed, as well as the most significant results and improvements in the challenging task of purifying plasmids.

  15. New approach for separating Bacillus subtilis metalloprotease and alpha-amylase by affinity chromatography and for purifying neutral protease by hydrophobic chromatography.

    PubMed

    Lauer, I; Bonnewitz, B; Meunier, A; Beverini, M

    2000-01-14

    Proteases are commonly used in the biscuit and cracker industry as processing aids. They cause moderate hydrolysis of gluten proteins and improve dough rheology to better control product texture and crunchiness. Commercial bacterial proteases are derived from Bacillus fermentation broth. As filtration and ultrafiltration are carried out as the only recovery steps, these preparations contain also alpha-amylase and beta-glucanase as the main side activities. The aim of this study is to purify and characterize the Bacillus subtilis metalloprotease from a commercial preparation, in order to study separately the impact of the protease activity with regards to its functionality on biscuit properties. Purification was achieved by means of affinity chromatography on Cibacron Blue and HIC as a polishing step. Affinity appeared to be the most appropriate matrix for large scale purification while ion exchange chromatography was inefficient in terms of recovery yields. The crude product was first loaded on a Hi Trap Blue column (34 microm, Pharmacia Biotech); elution was carried out with a gradient of NaCl in the presence of 1 mM ZnCl2. This step was only efficient in the presence of Zn cations, because this salt promoted both protease stabilization resulting in high recovery yields and also complexation of amylase units into dimers resulting in amylase retention on the column and a better separation of the 3 activities. Beta-glucanase was mostly non retained on the column and a part was coeluted with the protease. This protease fraction was then loaded on a Resource Phe column (15 microm, Pharmacia Biotech) in a last step of polishing. Elution was carried out with a linear gradient of 100-0% ammonium sulfate 1.3 M; protease was eluted at the beginning of the gradient and well separated from amylase and glucanase trace impurities. The homogeneity of the purified protease was confirmed by SDS-PAGE, which showed that its MW was about 38. pH and temperature optima were also

  16. Multi-column chromatography of urinary steriods and adrenocortical dysfunction.

    PubMed

    Sayegh, J F; Vestergaard, P

    1978-01-01

    The potential of the multi-column assay for urinary neutral steroids in work with samples from patients with adrenocortical pathology is demonstrated through analyses performed on urine samples from Cushing and congenital adrenal hyperplasia cases, after modification of the routine methodology to include the quantitation of additional steroids of particular importance for pathological samples.

  17. Robust naphthyl methacrylate monolithic column for high performance liquid chromatography of a wide range of solutes.

    PubMed

    Jonnada, Murthy; El Rassi, Ziad

    2015-08-28

    An organic monolithic column based on the co-polymerization of 2-naphthyl methacrylate (NAPM) as the functional monomer and trimethylolpropane trimethacrylate (TRIM) as the crosslinker was introduced for high performance reversed-phase liquid chromatography (RPC). The co-polymerization was performed in situ in a stainless steel column of 4.6mm i.d. in the presence of a ternary porogen consisting of 1-dodecanol and cyclohexanol. This monolithic column (referred to as naphthyl methacrylate monolithic column or NMM column) showed high mechanical stability at relatively high mobile phase flow velocity indicating that the column has excellent hydrodynamic characteristics. To characterize the NMM column, different probe molecules including alkyl benzenes, and aniline, benzene, toluene and phenol derivatives were chromatographed on the column and the results in terms of k, selectivity and plate counts were compared to those obtained on an octadecyl silica (ODS) column in order to assess the presence of π-π and hydrophobic interactions on the NMM column under otherwise the same elution conditions. The NMM column offered additional π-π interactions with aromatic molecules in addition to hydrophobic interactions under RPC elution conditions. Run-to-run and column-to-column reproducibility of solute k values were evaluated, and percent relative standard deviation of <1% and ∼2-3.5%, respectively, were obtained. Six standard proteins were readily separated on the NMM column using shallow (30min at 1.0mL/min), steep (10min at 1.0mL/min) and ultra steep (1min at 3.0mL/min) linear gradient elution at increasing ACN concentration in the mobile phase using a 10cm×4.6mm i.d. column in case of shallow and steep linear gradients and a 3cm×4.6mm i.d. column for ultra steep linear gradient.

  18. How to select equivalent and complimentary reversed phase liquid chromatography columns from column characterization databases.

    PubMed

    Borges, Endler M

    2014-01-07

    Three RP-LC column characterization protocols [Tanaka et al. (1989), Snyder et al. (PQRI, 2002), and NIST SRM 870 (2000)] were evaluated using both Euclidian distance and Principal Components Analysis to evaluate effectiveness at identifying equivalent columns. These databases utilize specific chromatographic properties such as hydrophobicity, hydrogen bonding, shape/steric selectivity, and ion exchange capacity of stationary phases. The chromatographic parameters of each test were shown to be uncorrelated. Despite this, the three protocols were equally successful in identifying similar and/or dissimilar stationary phases. The veracity of the results has been supported by some real life pharmaceutical separations. The use of Principal Component Analysis to identify similar/dissimilar phases appears to have some limitations in terms of loss of information. In contrast, the use of Euclidian distances is a much more convenient and reliable approach. The use of auto scaled data is favoured over the use of weighted factors as the former data transformation is less affected by the addition or removal of columns from the database. The use of these free databases and their corresponding software tools shown to be valid for identifying similar columns with equivalent chromatographic selectivity and retention as a "backup column". In addition, dissimilar columns with complimentary chromatographic selectivity can be identified for method development screening strategies.

  19. Highly crosslinked silicon polymers for gas chromatography columns

    NASA Technical Reports Server (NTRS)

    Shen, Thomas C. (Inventor)

    1994-01-01

    A new highly crosslinked silicone polymer particle for gas chromatography application and a process for synthesizing such copolymer are described. The new copolymer comprises vinyltriethoxysilane and octadecyltrichlorosilane. The copolymer has a high degree of crosslinking and a cool balance of polar to nonpolar sites in the porous silicon polymer assuring fast separation of compounds of variable polarity.

  20. Developing Inquiry-Based Labs Using Micro-Column Chromatography

    ERIC Educational Resources Information Center

    Barden-Gabbei, Laura M.; Moffitt, Deborah L.

    2006-01-01

    Chromatography is a process by which mixtures can be separated or substances can be purified. Biological and chemical laboratories use many different types of chromatographic processes. For example, the pharmaceutical industry uses chromatographic techniques to purify drugs, medical labs use them to identify blood components such as cholesterol,…

  1. Characterization of the efficiency of microbore liquid chromatography columns by van Deemter and kinetic plot analysis.

    PubMed

    Hetzel, Terence; Loeker, Denise; Teutenberg, Thorsten; Schmidt, Torsten C

    2016-10-01

    The efficiency of miniaturized liquid chromatography columns with inner diameters between 200 and 300 μm has been investigated using a dedicated micro-liquid chromatography system. Fully porous, core-shell and monolithic commercially available stationary phases were compared applying van Deemter and kinetic plot analysis. The sub-2 μm fully porous as well as the 2.7 μm core-shell particle packed columns showed superior efficiency and similar values for the minimum reduced plate heights (2.56-2.69) before correction for extra-column contribution compared to normal-bore columns. Moreover, the influence of extra-column contribution was investigated to demonstrate the difference between apparent and intrinsic efficiency by replacing the column by a zero dead volume union to determine the band spreading caused by the system. It was demonstrated that 72% of the intrinsic efficiency could be reached. The results of the kinetic plot analysis indicate the superior performance of the sub-2 μm fully porous particle packed column for ultra-fast liquid chromatography.

  2. Routes to improve binding capacities of affinity resins demonstrated for Protein A chromatography.

    PubMed

    Müller, Egbert; Vajda, Judith

    2016-05-15

    Protein A chromatography is a well-established platform in downstream purification of monoclonal antibodies. Dynamic binding capacities are continuously increasing with almost every newly launched Protein A resin. Nevertheless, binding capacities of affinity chromatography resins cannot compete with binding capacities obtained with modern ion exchange media. Capacities of affinity resins are roughly 50% lower. High binding capacities of ion exchange media are supported by spacer technologies. In this article, we review existing spacer technologies of affinity chromatography resins. A yet known effective approach to increase the dynamic binding capacity of Protein A resins is oligomerization of the particular Protein A motifs. This resembles the tentacle technology used in ion exchange chromatography. Dynamic binding capacities of a hexameric ligand are roughly twice as high compared to capacities obtained with a tetrameric ligand. Further capacity increases up to 130mg/ml can be realized with the hexamer ligand, if the sodium phosphate buffer concentration is increased from 20 to 100mM. Equilibrium isotherms revealed a BET shape for the hexamer ligand at monoclonal antibody liquid phase concentrations higher than 9mg/ml. The apparent multilayer formation may be due to hydrophobic forces. Other quality attributes such as recovery, aggregate content, and overall purity of the captured monoclonal antibody are not affected.

  3. Affinity chromatography of Band 3, the anion transport protein of erythrocyte membranes.

    PubMed

    Pimplikar, S W; Reithmeier, R A

    1986-07-25

    Affinity chromatography of Band 3 was performed using a series of affinity matrices synthesized with various inhibitor ligands and spacer arms. Hydrophilic spacer arms greater than four atoms in length were essential for Band 3 binding. An affinity resin prepared by reacting 4-acetamido-4'-isothiocyanostilbene-2,2'-disulfonate (Ki = 10 microM) with Affi-Gel 102 was found to be the most effective resin of the series tested. Solubilized proteins from human erythrocyte membranes were incubated with the affinity resin, and pure Band 3 was recovered by eluting with 4-benzamido-4'-aminostilbene-2,2'-disulfonate (BADS; Ki = 2 microM). Band 3 bound to the resin specifically in its stilbene disulfonate binding site, and optimal binding was achieved at pH 8 and at high ionic strength. At 4 degrees C, up to 80% of the bound Band 3 could be eluted by 1 mM BADS, whereas the remainder could be eluted under denaturing conditions using 1% lithium dodecyl sulfate. At 22 or 37 degrees C, the amount of BADS-elutable Band 3 was reduced with a concomitant increase of Band 3 in the lithium dodecyl sulfate elute. Thus, for successful affinity chromatography, the experiment must be carried out rapidly at 4 degrees C. This procedure was also used to purify the Band 3 protein from mouse, horse, pig, and chicken erythrocytes.

  4. Enrichment of phosphorylated proteins from cell lysate using a novel phosphate-affinity chromatography at physiological pH.

    PubMed

    Kinoshita-Kikuta, Emiko; Kinoshita, Eiji; Yamada, Atsushi; Endo, Mika; Koike, Tohru

    2006-10-01

    While phosphoproteins have attracted great interest toward the post-genome research (e.g. clinical diagnosis and drug design), there have been few procedures for the specific enrichment of native phosphoproteins from cells or tissues. Here, we describe a simple and efficient protocol to enrich phosphoproteins comprehensively from a complex mixture containing solubilized cellular proteins. This method is based on immobilized metal affinity chromatography using a phosphate-binding tag molecule (i.e. a dinuclear zinc(II) complex) attached on a highly cross-linked agarose. The binding, washing, and elution processes were all conducted without a detergent or a reducing agent at pH 7.5 and room temperature. An additive, 1.0 M CH3COONa, was necessary in the binding and washing buffers (0.10 M Tris-CH3COOH, pH 7.5) to prevent the nonphosphorylated protein from binding. The absorbed phosphoproteins were eluted using a mixed buffer solution (pH 7.5) consisting of 0.10 M Tris-CH3COOH, 10 mM NaH2PO4-NaOH, and 1.0 M NaCl. In this study, we demonstrate a typical example of phosphate-affinity chromatography using an epidermal growth factor-stimulated A431 cell lysate. The total time for the column chromatography (1 mL gel scale) was less than 1 h. The strong enrichment of the phosphoproteins into the elution fraction was evaluated using SDS-PAGE followed by Western blotting analysis.

  5. Comprehensive two-dimensional high performance liquid chromatography system with immobilized liposome chromatography column and monolithic column for separation of the traditional Chinese medicine Schisandra chinensis.

    PubMed

    Wang, Shuowen; Wang, Chen; Zhao, Xin; Mao, Shilong; Wu, Yutian; Fan, Guorong

    2012-02-03

    A comprehensive two-dimensional (2D) separation is one that employs two separation dimensions (columns) and draws on all of the available resolving power from each of the dimensions of separate the components in a sample. In this study, a comprehensive 2D chromatography approach was developed for the separation and identification of membrane permeable compounds in a famous traditional Chinese medicine of Schisandra chinensis. The first dimensional column was the immobilized liposome chromatography (ILC) column, which mimics the biological membranes and can be used to study drug-membrane interactions in liquid chromatography. Using an automatic ten-port switching valve equipped with two sample loops, the section of the first-dimension was introduced in the second-dimension consist of a silica monolithic column. More than 40 components in Schisandra chinensis were resolved by using the developed separation system and among them 14 compounds were identified interacting with the ILC column based on their retention action, UV and mass data. With this comprehensive 2D-HPLC system, the three-dimensional chromatographic fingerprints of Schisandra chinensis were preliminarily established and processed by using principal component analysis and hierarchical clustering analysis. The obtained information can distinguish the unacceptable samples of the quality control. The result demonstrated that the 2D biochromatography system has been demonstrated to have more advantages of finding strong binding bioactive components, providing an enhanced peak capacity, good sensitivity and powerful resolution biological fingerprinting analysis of complex TCMs, which was a useful means to control the quality of and to clarify the membrane permeability of the compounds in Schisandra chinensis.

  6. Analyzing insulin samples by size-exclusion chromatography: a column degradation study.

    PubMed

    Teska, Brandon M; Kumar, Amit; Carpenter, John F; Wempe, Michael F

    2015-04-01

    Investigating insulin analogs and probing their intrinsic stability at physiological temperature, we observed significant degradation in the size-exclusion chromatography (SEC) signal over a moderate number of insulin sample injections, which generated concerns about the quality of the separations. Therefore, our research goal was to identify the cause(s) for the observed signal degradation and attempt to mitigate the degradation in order to extend SEC column lifespan. In these studies, we used multiangle light scattering, nuclear magnetic resonance, and gas chromatography-mass spectrometry methods to evaluate column degradation. The results from these studies illustrate: (1) that zinc ions introduced by the insulin product produced the observed column performance issues; and (2) that including ethylenediaminetetraacetic acid, a zinc chelator, in the mobile phase helped to maintain column performance.

  7. Evaluation of a silicon oxynitride hydrophilic interaction liquid chromatography column in saccharide and glycoside separations.

    PubMed

    Wan, Huihui; Sheng, Qianying; Zhong, Hongmin; Guo, Xiujie; Fu, Qing; Liu, Yanfang; Xue, Xingya; Liang, Xinmiao

    2015-05-01

    The retention characteristics of a silicon oxynitride stationary phase for carbohydrate separation were studied in hydrophilic interaction chromatography mode. Four saccharides including mono-, di-, and trisaccharides were employed to investigate the effects of water content and buffer concentration in the mobile phase on hydrophilic interaction liquid chromatography retention. For the tested saccharides, the silicon oxynitride column demonstrated excellent performance in terms of separation efficiency, hydrophilicity, and interesting separation selectivity for carbohydrates compared to the bare silica stationary phase. Finally, the silicon oxynitride hydrophilic interaction liquid chromatography column was employed in the separation of complex samples of fructooligosaccharides, saponins, and steviol glycoside from natural products. The resulting chromatograms demonstrated good separation efficiency and longer retention compared with silica, which further confirmed the advantages and potential application of silicon oxynitride stationary phase for hydrophilic interaction liquid chromatography separation.

  8. One-pot preparation of a sulfamethoxazole functionalized affinity monolithic column for selective isolation and purification of trypsin.

    PubMed

    Xiao, Yuan; Guo, Jialiang; Ran, Danni; Duan, Qianqian; Crommen, Jacques; Jiang, Zhengjin

    2015-06-26

    A facile and efficient "one-pot" copolymerization strategy was used for the preparation of sulfonamide drug (SA) functionalized monolithic columns. Two novel SA-immobilized methacrylate monolithic columns, i.e. poly(GMA-SMX-co-EDMA) and poly(GMA-SAA-co-EDMA) were prepared by one-pot in situ copolymerization of the drug ligand (sulfamethoxazole (SMX) or sulfanilamide (SAA)), the monomer (glycidyl methacrylate, GMA) and the cross-linker (ethylene dimethacrylate, EDMA) within 100 μm i.d. capillaries under optimized polymerization conditions. The physicochemical properties and column performance of the fabricated monolithic columns were characterized by elemental analysis, scanning electron microscopy and micro-HPLC. Satisfactory column permeability, efficiency and separation performance were obtained on the optimized poly(GMA-SMX-co-EDMA) monolithic column for small molecules, such as a standard test mixture and eight aromatic ketones. Notably, it was found that the poly(GMA-SMX-co-EDMA) monolith showed a selective affinity to trypsin, while the poly(GMA-SAA-co-EDMA) monolith containing sulfanilamide did not exhibit such affinity at all. This research not only provides a novel monolith for the selective isolation and purification of trypsin, but it also offers the possibility to easily prepare novel drug functionalized methacrylate monoliths through a one-pot copolymerization strategy.

  9. Chemometrics applications in biotechnology processes: predicting column integrity and impurity clearance during reuse of chromatography resin.

    PubMed

    Rathore, Anurag S; Mittal, Shachi; Lute, Scott; Brorson, Kurt

    2012-01-01

    Separation media, in particular chromatography media, is typically one of the major contributors to the cost of goods for production of a biotechnology therapeutic. To be cost-effective, it is industry practice that media be reused over several cycles before being discarded. The traditional approach for estimating the number of cycles a particular media can be reused for involves performing laboratory scale experiments that monitor column performance and carryover. This dataset is then used to predict the number of cycles the media can be used at manufacturing scale (concurrent validation). Although, well accepted and widely practiced, there are challenges associated with extrapolating the laboratory scale data to manufacturing scale due to differences that may exist across scales. Factors that may be different include: level of impurities in the feed material, lot to lot variability in feedstock impurities, design of the column housing unit with respect to cleanability, and homogeneity of the column packing. In view of these challenges, there is a need for approaches that may be able to predict column underperformance at the manufacturing scale over the product lifecycle. In case such an underperformance is predicted, the operators can unpack and repack the chromatography column beforehand and thus avoid batch loss. Chemometrics offers one such solution. In this article, we present an application of chemometrics toward the analysis of a set of chromatography profiles with the intention of predicting the various events of column underperformance including the backpressure buildup and inefficient deoxyribonucleic acid clearance.

  10. Characterization of peak capacity of microbore liquid chromatography columns using gradient kinetic plots.

    PubMed

    Hetzel, Terence; Blaesing, Christina; Jaeger, Martin; Teutenberg, Thorsten; Schmidt, Torsten C

    2017-02-17

    The performance of micro-liquid chromatography columns with an inner diameter of 0.3mm was investigated on a dedicated micro-LC system for gradient elution. Core-shell as well as fully porous particle packed columns were compared on the basis of peak capacity and gradient kinetic plot limits. The results for peak capacity showed the superior performance of columns packed with sub-2μm fully porous particles compared to 3.0μm fully porous and 2.7μm core-shell particles within a range of different gradient time to column void time ratios. For ultra-fast chromatography a maximum peak capacity of 16 can be obtained using a 30s gradient for the sub-2μm fully porous particle packed column. A maximum peak capacity of 121 can be achieved using a 5min gradient. In addition, the influence of an alternative detector cell on the basis of optical waveguide technology and contributing less to system variance was investigated showing an increased peak capacity for all applied gradient time/column void time ratios. Finally, the influence of pressure was evaluated indicating increased peak capacity for maximum performance whereas a limited benefit for ultra-fast chromatography with gradient times below 30s was observed.

  11. Improved micromachined column design and fluidic interconnects for programmed high-temperature gas chromatography separations.

    PubMed

    Gaddes, David; Westland, Jessica; Dorman, Frank L; Tadigadapa, Srinivas

    2014-07-04

    This work focuses on the development and experimental evaluation of micromachined chromatographic columns for use in a commercial gas chromatography (GC) system. A vespel/graphite ferrule based compression sealing technique is presented using which leak-proof fluidic interconnection between the inlet tubing and the microchannel was achieved. This sealing technique enabled separation at temperatures up to 350°C on a μGC column. This paper reports the first high-temperature separations in microfabricated chromatographic columns at these temperatures. A 2m microfabricated column using a double Archimedean spiral design with a square cross-section of 100μm×100μm has been developed using silicon microfabrication techniques. The microfabricated column was benchmarked against a 2m 100μm diameter commercial column and the performance between the two columns was evaluated in tests performed under identical conditions. High temperature separations of simulated distillation (ASTM2887) and polycyclic aromatic hydrocarbons (EPA8310) were performed using the μGC column in temperature programmed mode. The demonstrated μGC column along with the high temperature fixture offers one more solution toward potentially realizing a portable μGC device for the detection of semi-volatile environmental pollutants and explosives without the thermal limitations reported to date with μGC columns using epoxy based interconnect technology.

  12. Affinity chromatography of porcine pepsin A using quinolin-8-ol as ligand.

    PubMed

    Novotná, Lenka; Hrubý, Martin; Benes, Milan J; Kucerová, Zdenka

    2005-08-19

    Stationary phase containing quinolin-8-ol immobilized on macroporous methacrylate support for the affinity chromatography of porcine pepsin A is described. Optimized chromatographic conditions for separation of porcine pepsin A on this stationary phase were found investigating the influence of pH, concentration, ionic strength and chemical composition of the used mobile phases. The stationary phase shows a good reproducibility of chromatographic analyses (relative standard deviation, +/-2%), a high recovery (ca. 93%) and a satisfactory capacity (13 mg pepsin A/1 mL stationary phase) for porcine pepsin A. The obtained findings confirm the applicability of affinity chromatography on the stationary phase with immobilized quinolin-8-ol to the isolation and determination of porcine pepsin A.

  13. Identification of potential cellular targets of aloisine A by affinity chromatography.

    PubMed

    Corbel, Caroline; Haddoub, Rose; Guiffant, Damien; Lozach, Olivier; Gueyrard, David; Lemoine, Jérôme; Ratin, Morgane; Meijer, Laurent; Bach, Stéphane; Goekjian, Peter

    2009-08-01

    Affinity chromatography was used to identify potential cellular targets of aloisine A (7-n-butyl-6-(4'-hydroxyphenyl)-5H-pyrrolo[2,3b]pyrazine), a potent inhibitor of cyclin-dependent kinases. This technique is based on the immobilization of the drug on a solid matrix, followed by identification of specifically bound proteins. To this end, both aloisine A and the protein-kinase inactive control N-methyl aloisine, bearing extended linker chains have been synthesized. We present the preparation of such analogues having the triethylene glycol chain at different positions of the molecule, as well as their immobilization on an agarose-based matrix. Affinity chromatography of various biological extracts on the aloisine matrices allowed the identification of both protein kinases and non-kinase proteins as potential cellular targets of aloisine.

  14. Effect of extra-column volume on practical chromatographic parameters of sub-2-μm particle-packed columns in ultra-high pressure liquid chromatography.

    PubMed

    Wu, Naijun; Bradley, Ashley C; Welch, Christopher J; Zhang, Li

    2012-08-01

    Effects of extra-column volume on apparent separation parameters were studied in ultra-high pressure liquid chromatography with columns and inlet connection tubings of various internal diameters (id) using 50-mm long columns packed with 1.8-μm particles under isocratic conditions. The results showed that apparent retention factors were on average 5, 11, 18, and 41% lower than those corrected with extra-column volumes for 4.6-, 3.0-, 2.1-, and 1.0-mm id columns, respectively, when the extra-column volume (11.3 μL) was kept constant. Also, apparent pressures were 31, 16, 12, and 10% higher than those corrected with pressures from extra-column volumes for 4.6-, 3.0-, 2.1-, and 1.0-mm id columns at the respective optimum flow rate for a typical ultra-high pressure liquid chromatography system. The loss in apparent efficiency increased dramatically from 4.6- to 3.0- to 2.1- to 1.0-mm id columns, less significantly as retention factors increased. The column efficiency was significantly improved as the inlet tubing id was decreased for a given column. The results suggest that maximum ratio of extra-column volume to column void volume should be approximately 1:10 for column porosity more than 0.6 and a retention factor more than 5, where 80% or higher of theoretically predicted efficiency could be achieved.

  15. Preparation of adsorbents for affinity chromatography using TSKgel Tresyl-Toyopearl 650M.

    PubMed

    Nakamura, K; Toyoda, K; Kato, Y; Shimura, K; Kasai, K

    1989-09-08

    The optimum conditions for the coupling of proteins were investigated using TSKgel Tresyl-Toyopearl 650M. They were dependent on the proteins coupled. For example, when soybean trypsin inhibitor was coupled at pH 8 the coupling was completed within 1 h and the subsequent adsorption capacity for trypsin was maximal. Longer coupling times decreased the adsorption capacity due to multi-point attachment. The adsorbents obtained were successfully used for affinity chromatography in a short time.

  16. Control of column temperature in reversed-phase liquid chromatography.

    PubMed

    Wolcott, R G; Dolan, J W; Snyder, L R; Bakalyar, S R; Arnold, M A; Nichols, J A

    2000-02-11

    When separations by reversed-phase liquid chromatography (RP-LC) are carried out at temperatures other than ambient, resulting retention times and bandwidths can depend on the equipment used. As a result, an RP-LC separation that is adequate when carried out on one LC system may prove inadequate when the separation is repeated on a second system. In the present study, various temperature-related problems which can result in a failure of method transfer for non-ambient RP-LC methods were examined. Means for correcting for such effects and thereby ensuring method transferability are described.

  17. Sub-to super-ambient temperature programmable microfabricated gas chromatography column

    DOEpatents

    Robinson, Alex L.; Anderson, Lawrence F.

    2004-03-16

    A sub- to super-ambient temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by combining a thermoelectric cooler and temperature sensing on the microfabricated column. Sub-ambient temperature programming enables the efficient separation of volatile organic compounds and super-ambient temperature programming enables the elution of less volatile analytes within a reasonable time. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.

  18. Method for trapping affinity chromatography of transcription factors using aldehyde-hydrazide coupling to agarose.

    PubMed

    Jia, Yinshan; Jarrett, Harry W

    2015-08-01

    The use of a method of coupling DNA was investigated for trapping and purifying transcription factors. Using the GFP-C/EBP (CAAT/enhancer binding protein) fusion protein as a model, trapping gives higher purity and comparable yield to conventional affinity chromatography. The chemistry used is mild and was shown to have no detrimental effect on GFP fluorescence or GFP-C/EBP DNA binding. The method involves introducing a ribose nucleotide to the 3' end of a DNA sequence. Reaction with mM NaIO4 (sodium metaperiodate) produces a dialdehyde of ribose that couples to hydrazide-agarose. The DNA is combined at nM concentration with a nuclear extract or other protein mixture, and DNA-protein complexes form. The complex is then coupled to hydrazide-agarose for trapping the DNA-protein complex and the protein eluted by increasing NaCl concentration. Using a different oligonucleotide with the proximal E-box sequence from the human telomerase promoter, USF-2 transcription factor was purified by trapping, again with higher purity than results from conventional affinity chromatography and similar yield. Other transcription factors binding E-boxes, including E2A, c-Myc, and Myo-D, were also purified, but myogenin and NFκB were not. Therefore, this approach proved to be valuable for both affinity chromatography and the trapping approach.

  19. A novel approach for separating bacteriophages from other bacteriophages using affinity chromatography and phage display.

    PubMed

    Ceglarek, Izabela; Piotrowicz, Agnieszka; Lecion, Dorota; Miernikiewicz, Paulina; Owczarek, Barbara; Hodyra, Katarzyna; Harhala, Marek; Górski, Andrzej; Dąbrowska, Krystyna

    2013-11-14

    Practical applications of bacteriophages in medicine and biotechnology induce a great need for technologies of phage purification. None of the popular methods offer solutions for separation of a phage from another similar phage. We used affinity chromatography combined with competitive phage display (i) to purify T4 bacteriophage from bacterial debris and (ii) to separate T4 from other contaminating bacteriophages. In 'competitive phage display' bacterial cells produced both wild types of the proteins (expression from the phage genome) and the protein fusions with affinity tags (expression from the expression vectors). Fusion proteins were competitively incorporated into the phage capsid. It allowed effective separation of T4 from a contaminating phage on standard affinity resins.

  20. Preparation and characterization of fluorophenylboronic acid-functionalized affinity monolithic columns for the selective enrichment of cis-diol-containing biomolecules.

    PubMed

    Li, Qianjin; Liu, Zhen

    2015-01-01

    Boronate affinity monolithic columns have been developed into an important means for the selective recognition and capture of cis-diol-containing biomolecules, such as glycoproteins, nucleosides and saccharides. The ligands of boronic acids are playing an important role in boronate affinity monolithic columns. Although several boronate affinity monoliths with high affinity toward cis-diol-containing biomolecules have been reported, only few publications are focused on their detailed procedures for preparation and characterization. This chapter describes in detail the preparation and characterization of a boronate affinity monolithic column applying 2,4-difluoro-3-formyl-phenylboronic acid (DFFPBA) as a ligand. The DFFPBA-functionalized monolithic column not only exhibited an ultrahigh boronate affinity toward cis-diol-containing biomolecules, but also showed great potential for the selective enrichment of cis-diol-containing biomolecules in real samples.

  1. Methacrylate-bonded covalent-organic framework monolithic columns for high performance liquid chromatography.

    PubMed

    Liu, Li-Hua; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2017-01-06

    Covalent-organic frameworks (COFs) are a newfangled class of intriguing microporous materials. Considering their unique properties, COFs should be promising as packing materials for high performance liquid chromatography (HPLC). However, the irregular shape and sub-micrometer size of COFs synthesized via the traditional methods render the main obstacles for the application of COFs in HPLC. Herein, we report the preparation of methacrylate-bonded COF monolithic columns for HPLC to overcome the above obstacles. The prepared COF bonded monolithic columns not only show good homogeneity and permeability, but also give high column efficiency, good resolution and precision for HPLC separation of small molecules including polycyclic aromatic hydrocarbons, phenols, anilines, nonsteroidal anti-inflammatory drugs and benzothiophenes. Compared with the bare polymer monolithic column, the COF bonded monolithic columns show enhanced hydrophobic, π-π and hydrogen bond interactions in reverse phase HPLC. The results reveal the great potential of COF bonded monoliths for HPLC and COFs in separation sciences.

  2. Immobilized palladium(II) ion affinity chromatography for recovery of recombinant proteins with peptide tags containing histidine and cysteine.

    PubMed

    Kikot, Pamela; Polat, Aise; Achilli, Estefania; Fernandez Lahore, Marcelo; Grasselli, Mariano

    2014-11-01

    Fusion of peptide-based tags to recombinant proteins is currently one of the most used tools for protein production. Also, immobilized metal ion affinity chromatography (IMAC) has a huge application in protein purification, especially in research labs. The combination of expression systems of recombinant tagged proteins with this robust chromatographic system has become an efficient and rapid tool to produce milligram-range amounts of proteins. IMAC-Ni(II) columns have become the natural partners of 6xHis-tagged proteins. The Ni(II) ion is considered as the best compromise of selectivity and affinity for purification of a recombinant His-tagged protein. The palladium(II) ion is also able to bind to side chains of amino acids and form ternary complexes with iminodiacetic acid and free amino acids and other sulfur-containing molecules. In this work, we evaluated two different cysteine- and histidine-containing six amino acid tags linked to the N-terminal group of green fluorescent protein (GFP) and studied the adsorption and elution conditions using novel eluents. Both cysteine-containing tagged GFPs were able to bind to IMAC-Pd(II) matrices and eluted successfully using a low concentration of thiourea solution. The IMAC-Ni(II) system reaches less than 20% recovery of the cysteine-containing tagged GFP from a crude homogenate of recombinant Escherichia coli, meanwhile the IMAC-Pd(II) yields a recovery of 45% with a purification factor of 13.

  3. Separation and purification of epigallocatechin-3-gallate (EGCG) from green tea using combined macroporous resin and polyamide column chromatography.

    PubMed

    Jin, Xin; Liu, Mingyan; Chen, Zaixing; Mao, Ruikun; Xiao, Qinghuan; Gao, Hua; Wei, Minjie

    2015-10-01

    Epigallocatechin-3-gallate (EGCG) is a major bioactive ingredient of green tea that produces beneficial neuroprotective effects. In this paper, to optimize the EGCG enrichment, thirteen macroporous resins with different chemical and physical properties were systemically evaluated. Among the thirteen tested resins, the H-bond resin HPD826 exhibited best adsorption/desorption capabilities and desorption ratio, as well as weakest affinity for caffeine. The absorption of EGCG on the HPD826 resin followed the pseudo-second-order kinetics and Langmuir isotherm model. The separation parameters of EGCG were optimized by dynamic adsorption/desorption experiments with the HPD826 resin column. Under the optimal condition, the content of EGCG in the 30% ethanol eluent increased by 5.8-fold from 7.7% to 44.6%, with the recovery yield of 72.1%. After further purification on a polyamide column, EGCG with 74.8% purity was obtained in the 40-50% ethanol fraction with a recovery rate of 88.4%. In addition, EGCG with 95.1% purity could be easily obtained after one-step crystallization in distilled water. Our study suggests that the combined macroporous resin and polyamide column chromatography is a simple method for large-scale separation and purification of EGCG from natural plants for food and pharmaceutical applications.

  4. Technical advance: identification of plant actin-binding proteins by F-actin affinity chromatography

    NASA Technical Reports Server (NTRS)

    Hu, S.; Brady, S. R.; Kovar, D. R.; Staiger, C. J.; Clark, G. B.; Roux, S. J.; Muday, G. K.

    2000-01-01

    Proteins that interact with the actin cytoskeleton often modulate the dynamics or organization of the cytoskeleton or use the cytoskeleton to control their localization. In plants, very few actin-binding proteins have been identified and most are thought to modulate cytoskeleton function. To identify actin-binding proteins that are unique to plants, the development of new biochemical procedures will be critical. Affinity columns using actin monomers (globular actin, G-actin) or actin filaments (filamentous actin, F-actin) have been used to identify actin-binding proteins from a wide variety of organisms. Monomeric actin from zucchini (Cucurbita pepo L.) hypocotyl tissue was purified to electrophoretic homogeneity and shown to be native and competent for polymerization to actin filaments. G-actin, F-actin and bovine serum albumin affinity columns were prepared and used to separate samples enriched in either soluble or membrane-associated actin-binding proteins. Extracts of soluble actin-binding proteins yield distinct patterns when eluted from the G-actin and F-actin columns, respectively, leading to the identification of a putative F-actin-binding protein of approximately 40 kDa. When plasma membrane-associated proteins were applied to these columns, two abundant polypeptides eluted selectively from the F-actin column and cross-reacted with antiserum against pea annexins. Additionally, a protein that binds auxin transport inhibitors, the naphthylphthalamic acid binding protein, which has been previously suggested to associate with the actin cytoskeleton, was eluted in a single peak from the F-actin column. These experiments provide a new approach that may help to identify novel actin-binding proteins from plants.

  5. Modeling Transport in Gas Chromatography Columns for the Micro-ChemLab

    SciTech Connect

    ADKINS,DOUGLAS R.; FRYE-MASON,GREGORY CHARLES; HUDSON,MARY L.; KOTTENSTETTE,RICHARD; MATZKE,CAROLYN M.; SALINGER,ANDREW G.; SHADID,JOHN N.; WONG, CHUNGNIN CHANN

    1999-09-01

    The gas chromatography (GC) column is a critical component in the microsystem for chemical detection ({mu}ChemLab{trademark}) being developed at Sandia. The goal is to etch a meter-long GC column onto a 1-cm{sup 2} silicon chip while maintaining good chromatographic performance. Our design strategy is to use a modeling and simulation approach. We have developed an analytical tool that models the transport and surface interaction process to achieve an optimized design of the GC column. This analytical tool has a flow module and a separation module. The flow module considers both the compressibility and slip flow effects that may significantly influence the gas transport in a long and narrow column. The separation module models analyte transport and physico-chemical interaction with the coated surface in the GC column. It predicts the column efficiency and performance. Results of our analysis will be presented in this paper. In addition to the analytical tool, we have also developed a time-dependent adsorption/desorption model and incorporated this model into a computational fluid dynamics (CFD) code to simulate analyte transport and separation process in GC columns. CFD simulations can capture the complex three-dimensional flow and transport dynamics, whereas the analytical tool cannot. Different column geometries have been studied, and results will be presented in this paper. Overall we have demonstrated that the modeling and simulation approach can guide the design of the GC column and will reduce the number of iterations in the device development.

  6. Evaluation of column hardware on liquid chromatography-mass spectrometry of phosphorylated compounds.

    PubMed

    Sakamaki, Hiroshi; Uchida, Takeharu; Lim, Lee Wah; Takeuchi, Toyohide

    2015-02-13

    The influences of column hardware, such as chromatographic tubes and frits, on liquid chromatography-mass spectrometry (LC-MS) analysis of phosphorylated compounds were evaluated. The signal to noise ratio (S/N) and the intensity of flavin adenine dinucleotide (FAD) using a glass lined tube and polyethylene frit (GL-PE) column was approximately 170 and 90 times higher, respectively, than those using conventional stainless steel tube and stainless steel frit (S-S) column. In addition, the retention time of FAD using GL-PE column was the shortest compared to other columns. Interaction between phosphorylated compounds and metal ions in the flow path in the S-S column was stronger than that between them and the GL-PE column. Thus, the metal ions in the flow path in GL-PE column were low. Since the specific surface area of a pair of frits was 70 times larger than that of a chromatographic tube (150 mm×2.1 mm), the frits were found to have more effective improvement of the S/N as well as the intensity than the chromatographic tubes, when phosphorylated compounds were analyzed by LC-MS. When the evaluated phosphorylated compounds were analyzed by LC-MS(/MS) using a GL-PE column, the intensity and S/N were increased.

  7. Applications of monolithic columns in liquid chromatography-based clinical chemistry assays.

    PubMed

    Bunch, Dustin R; Wang, Sihe

    2011-08-01

    Monolithic columns have slowly been applied to HPLC methods for clinical chemistry testing in the last 10 years. The application areas include therapeutic drug monitoring, drugs of abuse, vitamins, porphyrins, and steroids. In comparison with conventional particulate columns, the monolithic columns may offer shorter chromatography time, more robustness, and better resolution for certain analytes. The potential drawback of large mobile phase consumption may be improved with smaller id columns, which are currently on the market. Methods covered in this review are those searchable in PubMed up to December 2010. This review highlights the emergence of monolithic column technology in HPLC methods used for clinical chemistry testing. The goals of this review are threefold: (i) To identify the areas of clinical chemistry that analytical monolithic columns have been used in HPLC methods. (ii) To demonstrate the application of analytical monolithic columns in HPLC methods using different detection systems. (iii) To discuss the advantages and limitations of the monolithic columns compared with particulate columns in the clinical chemistry applications.

  8. A Computer-Interfaced Drop Counter as an Inexpensive Fraction Collector for Column Chromatography

    ERIC Educational Resources Information Center

    Nash, Barbara T.

    2008-01-01

    A computer-interfaced drop counter is described that serves as an inexpensive alternative to a fraction collector for column chromatography experiments. Undergraduate biochemistry laboratories frequently do not have the budget to purchase fraction collectors. Protocols that call for the manual measurement of fraction volumes as well as the manual…

  9. Separation of the Carotenoid Bixin from Annatto Seeds Using Thin-Layer and Column Chromatography

    ERIC Educational Resources Information Center

    McCullagh, James V.; Ramos, Nicholas

    2008-01-01

    In this experiment the carotenoid bixin is isolated from annatto ("Bixa orellana") seeds using column chromatography. The experiment has several key advantages over previous pigment separation experiments. First, unlike other experiments significant quantities of the carotenoid (typically 20 to 25 mg) can be isolated from small quantities of plant…

  10. Purification to homogeneity of an active opioid receptor from rat brain by affinity chromatography.

    PubMed

    Loukas, S; Mercouris, M; Panetsos, F; Zioudrou, C

    1994-05-10

    Active opioid binding proteins were solubilized from rat brain membranes in high yield with sodium deoxycholate in the presence of NaCl. Purification of opioid binding proteins was accomplished by opioid antagonist affinity chromatography. Chromatography using the delta-opioid antagonist N,N-diallyl-Tyr-D-Leu-Gly-Tyr-Leu attached to omega-aminododecyl-agarose (Affi-G) (procedure A) yielded a partially purified protein that binds selectively the delta-opioid agonist [3H]Tyr-D-Ser-Gly-Phe-Leu-Thr ([3H]DSLET), with a Kd of 19 +/- 3 nM and a Bmax of 5.1 +/- 0.4 nmol/mg of protein. Subsequently, Lens culinaris agglutinin-Sepharose 4B chromatography of the Affi-G eluate resulted in isolation of an electrophoretically homogeneous protein of 58 kDa that binds selectively [3H]DSLET with a Kd of 21 +/- 3 nM and a Bmax of 16.5 +/- 1.0 nmol/mg of protein. Chromatography using the nonselective antagonist 6-aminonaloxone coupled to 6-aminohexanoic acid-Sepharose 4B (Affi-NAL) (procedure B) resulted in isolation of a protein that binds selectively [3H]DSLET with a Kd of 32 +/- 2 nM and a Bmax of 12.4 +/- 0.5 nmol/mg of protein, and NaDodSO4/PAGE revealed a major band of apparent molecular mass 58 kDa. Polyclonal antibodies (Anti-R IgG) raised against the Affi-NAL protein inhibit the specific [3H]DSLET binding to the Affi-NAL eluate and to the solubilized membranes. Moreover, the Anti-R IgG inhibits the specific binding of radiolabeled Tyr-D-Ala-Gly-N-methyl-Phe-Gly-ol (DAMGO; mu-agonist), DSLET (delta-agonist), and naloxone to homogenates of rat brain membranes with equal potency. Furthermore, immunoaffinity chromatography of solubilized membranes resulted in the retention of a major protein of apparent molecular mass 58 kDa. In addition, immunoblotting of solubilized membranes and purified proteins from the Affi-G and Affi-NAL matrices revealed that the Anti-R IgG interacts with a protein of 58 kDa.

  11. Investigation of Pinus mugo essential oil oxygenated fraction by combined use of gas chromatography and dry column chromatography.

    PubMed

    A, M B; Coran, S A; Giannellini, V; Vincieri, F F; Moneti, G

    1981-09-01

    The oxygenated compounds of Pinus mugo Turra essential oil were investigated by a combination of GC and dry column chromatography (DCC) coordinated by GC data processing. The collected data resulted in a bar graph ("normalized" gas chromatogram) giving the RRT's and relative amounts of 68 components; 38 of them were identified by MS and IR. The described procedure may be used for essential oil analysis in general.

  12. Use of differential dye-ligand chromatography with affinity elution for enzyme purification: 2-keto-3-deoxy-6-phosphogluconate aldolase from Zymomonas mobilis.

    PubMed

    Scopes, R K

    1984-02-01

    2-Keto-3-deoxy-6-phosphogluconate aldolase (EC 4.1.2.14) has been isolated from extracts of Zymomonas mobilis using differential dye-ligand chromatography and affinity elution with product/product analog. The one-step procedure gives an enzyme with specific activity 600 units mg-1. Only 1 out of 47 dyes, Procion Yellow MX-GR, bound the enzyme completely in 20 mM phosphate buffer, pH 6.5. A column of Navy HE-R adsorbent was used first to remove most of the potentially adsorbing proteins.

  13. Determination of soluble immunoglobulin G in bovine colostrum products by Protein G affinity chromatography-turbidity correction and method validation.

    PubMed

    Holland, Patrick T; Cargill, Anne; Selwood, Andrew I; Arnold, Kate; Krammer, Jacqueline L; Pearce, Kevin N

    2011-05-25

    Immunoglobulin-containing food products and nutraceuticals such as bovine colostrum are of interest to consumers as they may provide health benefits. Commercial scale colostrum products are valued for their immunoglobulin G (IgG) content and therefore require accurate analysis. One of the most commonly used methods for determining total soluble IgG in colostrum products is based on affinity chromatography using a Protein G column and UV detection. This paper documents improvements to the accuracy of the Protein G analysis of IgG in colostrum products, especially those containing aggregated forms of IgG. Capillary electrophoresis-sodium dodecyl sulfate (CE-SDS) analysis confirmed that aggregated IgG measured by Protein G does not contain significant amounts of casein or other milk proteins. Size exclusion chromatography identified the content of soluble IgG as mainly monomeric IgG and aggregated material MW > 450 kDa with small amounts of dimer and trimer. The turbidity of the eluting IgG, mainly associated with aggregated IgG, had a significant effect on the quantitative results. Practical techniques were developed to correct affinity LC data for turbidity on an accurate, consistent, and efficient basis. The method was validated in two laboratories using a variety of colostrum powders. Precision for IgG was 2-3% (RSD(r)) and 3-12% (RSD(R)). Recovery was 100.2 ± 2.4% (mean ± RSD, n = 10). Greater amounts of aggregated IgG were solubilized by a higher solution:sample ratio and extended times of mixing or sonication, especially for freeze-dried material. It is concluded that the method without acid precipitation and with turbidity correction provides accurate, precise, and robust data for total soluble IgG and is suitable for product specification and quality control of colostrum products.

  14. 5-O-caffeoylshikimic acid from Solanum somalense leaves: advantage of centrifugal partition chromatography over conventional column chromatography.

    PubMed

    Chideh, Saïda; Pilard, Serge; Attoumbré, Jacques; Saguez, Robert; Hassan-Abdallah, Alshaimaa; Cailleu, Dominique; Wadouachi, Anne; Baltora-Rosset, Sylvie

    2014-09-01

    Solanum somalense leaves, used in Djibouti for their medicinal properties, were extracted by MeOH. Because of the high polyphenol and flavonoid contents of the extract, respectively, determined at 80.80 ± 2.13 mg gallic acid equivalent/g dry weight and 24.4 ± 1.01 mg quercetin equivalent/g dry weight, the isolation and purification of the main polyphenols were carried out by silica gel column chromatography and centrifugal partition chromatography. Column chromatography led to 11 enriched fractions requiring further purification, while centrifugal partition chromatography allowed the easy recovery of the main compound of the extract. In a solvent system composed of CHCl3/MeOH/H2O (9.5:10:5), 21.8 mg of this compound at 97% purity was obtained leading to a yield of 2.63%. Its structure was established as 5-O-caffeoylshikimic acid by mass spectrometry and NMR spectroscopy. This work shows that S. somalense leaves contain very high level of 5-O-caffeoylshikimic acid (0.74% dry weight), making it a potential source of production of this secondary metabolite that is not commonly found in nature but could be partly responsible of the medicinal properties of S. somalense leaves.

  15. Hydrothermal preparation of hybrid carbon/silica monolithic capillary column for liquid chromatography.

    PubMed

    Yang, Peiling; Wang, Wentao; Xiao, Xing; Jia, Li

    2014-08-01

    A simple, easy and economical approach for the preparation of a hybrid carbon/silica monolithic capillary column was described for the first time by using silica monolith as framework in combination with hydrothermal carbonization at 180°C. During the preparation process, formamide was introduced to the reaction solutions to reduce the dissolution rate of monolithic silica skeleton and its optimal concentration was 1.5 M. Fourier transform infrared spectrometry, scanning electron microscopy, energy dispersive X-ray spectrometry, and inverse size exclusion chromatography were carried out to characterize the as-prepared column. The results demonstrated that carbon spheres ranging from 150 to 1000 nm were successfully attached to the surface of silica skeleton. The prepared hybrid carbon/silica column had a permeability of 4.4 × 10(-14) m(2). Chromatographic performance of the column was evaluated by separation of various compounds including alkylbenzenes, nucleosides and bases, and aromatic acids. The column exhibited an efficiency of 75,000 plates/m for butylbenzene at the optimal linear velocity of 0.23 mm/s. The successful separation of these compounds and the study on mechanism indicated that the column can be applied in mixed-mode chromatography.

  16. High-performance liquid chromatography of histamine and 1-methylhistamine with on-column fluorescence derivatization.

    PubMed

    Saito, K; Horie, M; Nose, N; Nakagomi, K; Nakazawa, H

    1992-03-20

    An on-column fluorometric derivatization method was developed for the determination of histamine and 1-methylhistamine (HMs) by high-performance liquid chromatography. The system for the derivatization consisted only of a commercially available single-plunger pump and a reversed-phase C18 column supported on synthetic polymer with a mobile phase of acetonitrile and alkaline borate buffer solution containing o-phthalaldehyde as a derivatization reagent. It required no additional reaction system as for a post-column derivatization method. Injected HMs might be derivatized to a fluorophore on the inlet site of the high-performance liquid chromatographic column, followed by chromatography on the same column. Optimization of the on-column reaction conditions resulted in a simple and sensitive analytical method for the determination of HMs with excellent reproducibility and linearity of 0.05-5 micrograms/ml of both HMs. Application of this method to the determination of HMs in food samples resulted in a limit of quantification of 0.05 mg/100 g and in a greater than 95% overall mean recovery at a fortification of 0.1 mg/g of both HMs. This method was furthermore applicable to the determination of histamine released from rat peritoneal mast cells.

  17. Quantification of PSP toxins in toxic shellfish matrices using post-column oxidation liquid chromatography and pre-column oxidation liquid chromatography methods suggests post-column oxidation liquid chromatography as a good monitoring method of choice.

    PubMed

    Rey, Verónica; Botana, Ana M; Botana, Luis M

    2017-04-01

    Different shellfish samples were analyzed by Pre- and Post-Column Oxidation Liquid Chromatography to compare the toxins profiles and get information about the degree of accomplishment of both methods. Comparison of the results obtained, the linear correlation coefficient (r(2) = 0.94) and the paired t test (two tails, α = 0.05), indicated that there were not significant differences between both sets of data. Nevertheless, important differences related to toxins profiles were found: it was remarkable the difference in results for both Gonyautoxins 1 and 4 and Decarbamoylgonyautoxins 2 and 3, depending on the method of choice, due to an overestimation in the Pre-Column method. It was necessary to modify the elution conditions in the Post-Column method to avoid the interference of matrix peaks at retention times closer to the retention times of the calibrants, mostly when working with oyster and scallop matrices, although it is a good method to use routinely.

  18. Post-column labeling techniques in amino acid analysis by liquid chromatography.

    PubMed

    Rigas, Pantelis G

    2013-10-01

    Amino acid analysis (AAA) has always presented an analytical challenge in terms of sample preparation, separation, and detection. Because of the vast number of amino acids, various separation methods have been applied taking into consideration the large differences in their chemical structures, which span from nonpolar to highly polar side chains. Numerous separation methods have been developed in the past 60 years, and impressive achievements have been made in the fields of separation, derivatization, and detection of amino acids (AAs). Among the separation methods, liquid chromatography (LC) prevailed in the AAA field using either pre-column or post-column labeling techniques in order to improve either separation of AAs or selectivity and sensitivity of AAA. Of the two approaches, the post-column technique is a more rugged and reproducible method and provides excellent AAs separation relatively free from interferences. This review considers current separations combined with post-column labeling techniques for AAA, comparison with the pre-column methods, and the strategies used to develop effective post-column methodology. The focus of the article is on LC methods coupled with post-column labeling techniques and studying the reactions to achieve optimum post-column derivatization (PCD) conditions in order to increase sensitivity and selectivity using various types of detectors (UV-Vis, fluorescence, electrochemical etc.) and illustrating the versatility of the PCD methods for practical analysis.

  19. Serial lectin affinity chromatography with concavalin A and wheat germ agglutinin demonstrates altered asparagine-linked sugar-chain structures of prostatic acid phosphatase in human prostate carcinoma.

    PubMed

    Yoshida, K I; Honda, M; Arai, K; Hosoya, Y; Moriguchi, H; Sumi, S; Ueda, Y; Kitahara, S

    1997-08-01

    Differences between human prostate carcinoma (PCA, five cases) and benign prostatic hyperplasia (BPH, five cases) in asparagine-linked (Asn) sugar-chain structure of prostatic acid phosphatase (PAP) were investigated using lectin affinity chromatography with concanavalin A (Con A) and wheat germ agglutinin (WGA). PAP activities were significantly decreased in PCA-derived PAP, while no significant differences between the two PAP preparations were observed in the enzymatic properties (Michaelis-Menten value, optimal pH, thermal stability, and inhibition study). In these PAP preparations, all activities were found only in the fractions which bound strongly to the Con A column and were undetectable in the Con A unbound fractions and in the fractions which bound weakly to the Con A column. The relative amounts of PAP which bound strongly to the Con A column but passed through the WGA column, were significantly greater in BPH-derived PAP than in PCA-derived PAP. In contrast, the relative amounts of PAP which bound strongly to the Con A column and bound to the WGA column, were significantly greater in PCA-derived PAP than in BPH-derived PAP. The findings suggest that Asn-linked sugar-chain structures are altered during oncogenesis in human prostate and also suggest that studies of qualitative differences of sugar-chain structures of PAP might lead to a useful diagnostic tool for PCA.

  20. A chemically cleavable biotinylated nucleotide: usefulness in the recovery of protein-DNA complexes from avidin affinity columns.

    PubMed Central

    Shimkus, M; Levy, J; Herman, T

    1985-01-01

    A biotinylated nucleotide analog containing a disulfide bond in the 12-atom linker joining biotin to the C-5 of the pyrimidine ring has been synthesized. This analog, Bio-SS-dUTP, is an efficient substrate for Escherichia coli DNA polymerase I. Bio-SS-dUTP supported DNA synthesis in a standard nick-translation reaction at 35%-40% the rate of an equal concentration of the normal nucleotide, TTP. DNA containing this analog was bound to an avidin-agarose affinity column and subsequently eluted after reduction of the disulfide bond by dithiothreitol. The ability to recover biotinylated DNA from an avidin affinity column under nondenaturing conditions should prove useful in the isolation of specific protein-DNA complexes. As a demonstration of this approach, Bio-SS-DNA was reconstituted with histones to form 11S monomer nucleosomes. Bio-SS-nucleosomes were shown to selectively bind to avidin-agarose. Ninety percent of the bound Bio-SS-nucleosomes were recovered from the affinity column by elution with buffer containing 50-500 mM dithiothreitol. The recovered nucleosomes were shown to be intact 11S particles as judged by velocity sedimentation in a sucrose gradient. This approach may prove to be generally useful in the isolation of protein-DNA complexes in a form suitable for further analysis of their native unperturbed structure. PMID:3887407

  1. Column switching liquid chromatography and post-column photochemically fluorescence detection to determine imidacloprid and 6-chloronicotinic acid in honeybees.

    PubMed

    García, M D Gil; Galera, M Martínez; Valverde, R Santiago; Galanti, A; Girotti, S

    2007-04-13

    The determination of imidacloprid and its main metabolite (6-chloronicotinic acid) in honeybees was performed by liquid chromatography with post-column photochemical derivatisation in alkaline medium and fluorescence detection. The compounds were extracted from honeybees with acetone under ultrasound conditions prior to liquid-liquid partition with dichloromethane. The separation of extract components was performed using a 50 mm x 4.6 mm i.d. short column packed with 5 microm Aquasil C(18) using an acetonitrile:water gradient program as mobile phase. Injection of samples in 0.1 mol L(-1) H(3)PO(4)/KH(2)PO(4) buffer solution (pH 3) improved the chromatographic separation between the most polar components of matrix and the 6-chloronicotinic acid. Matrix components were removed to waste using an on-line clean-up method previously to post-column reaction. Limits of quantification were 0.3 and 5.0 microg L(-1) (corresponding to 1.2 and 20.0 microg kg(-1) in the honeybee sample) for imidacloprid and 6-chloronicotinic acid, respectively. The recovery was ranged from 80.2 to 91.7% with a relative standard deviation lower than 9.0%.

  2. Determination of the column hold-up volume in supercritical fluid chromatography using nitrous-oxide.

    PubMed

    Vajda, Péter; Guiochon, Georges

    2013-09-27

    This study introduces a new tracer that is useful for the determination of the hold-up time or volume of packed columns, particularly of those used in supercritical fluid chromatography. The thermodynamic void volume of three columns packed with different adsorbents were determined using the weight difference method. These void volumes were used as the reference point in the further discussion. The hold-up volumes of these columns were determined under dynamic conditions, using nitrous oxide dissolved in methanol as the hold-up time marker. Changes in the hold-up volumes of these columns were monitored during changes of the volumetric flow rate of pure supercritical carbon dioxide and of dilute mixtures of organic modifier and supercritical carbon dioxide. The results suggest significant methanol enrichment on the adsorbent surface.

  3. Effects of Heterogeneous Adsorption Affinity on Natural Organic Matter (NOM) Transport in Laboratory Sand Columns

    NASA Astrophysics Data System (ADS)

    McInnis, D. P.; Bolster, D.; Maurice, P. A.

    2012-12-01

    Transport of reactive sorbing solutes through porous media is commonly quantified by implementing an effective retardation coefficient in the advection-dispersion equation (ADE), which describes dispersion in accordance with Fick's law. However, anomalous (non-Fickian) transport behavior can be observed in systems with heterogeneous retardation coefficients (Dentz & Castro, 2009). In such systems, the ADE is unable to reproduce the non-Fickian nature of plume shapes and breakthrough curves, motivating the development and application of alternative solute transport theories, such as the continuous time random walk (CTRW) or multi-rate mass transfer (MRMT). Heterogeneity in retardation coefficients in practice arises from variability in the geochemical properties controlling sorption-desorption kinetics between the solute and mineral surfaces. These distributions have been described in the context of heterogeneity of the porous medium, but to date little attention has been given to the potential role of a geochemically heterogeneous solute. In this work, we consider a system in which anomalous transport arises during the passage of natural organic matter (NOM), a polydisperse mixture of compounds derived from the breakdown of plants and microorganisms in the environment, through homogeneous laboratory sand columns. NOM solutions were passed through columns containing either hematite, corundum, or a naturally-coated quartz sand at a variety of pH and ionic strength conditions. Influent and effluent NOM concentration was measured as UV absorbance at 254 nm. The resulting breakthrough curves are non-Fickian, displaying power-law tailing at late times. Such curves cannot be predicted by the ADE model. Reactivity of NOM components is known to be related to their molecular weight (MW), which tends to be log-normally distributed in aquatic NOM isolates (Cabaniss et al., 2000). Low-MW compounds are more water-soluble, have a higher diffusion coefficient, and due to their

  4. Regenerated silica gel as stationary phase on vacuum column chromatography to purify temulawak's extracts

    NASA Astrophysics Data System (ADS)

    Cahyono, Bambang; Maduwu, Ratna Dewi; Widayat, Suzery, Meiny

    2015-12-01

    Commercial silica gel only used once by many researchers and affected high cost for purification process, also less support the green chemistry program. This research focused in regeneration silica gel that used purification of temulawak's extracts (Curcuma xanthorrhiza Roxb) by vacuum column chromatography. Sample extracts (contains 10.1195±0.5971% of curcuminoids) was purified by vacuum column chromatography (pressure: 45 kPa, column: 100mm on length and 16mm on diameter). Ethanol 96% and acetone were compared as eluent. The amount of solvent and yield of curcuminoids used as indicator purification. The silica gel was regenerated with heating in 600°C for 8 hours The silica gels were analyzed by IR spectroscopy and X-ray diffraction. Furthermore, regenerated silica gel was used as the stationary phase in vacuum column chromatography under the same conditions with the previous purification. All the purification experiments were performed in three repetitions. Based on regression equation, y=0.132x+0.0011 (r2=0.9997) the yield of curcuminoids on purified products using ethanol as the eluent was improved 4.26% (to 14.3724±0.5749%) and by acetone was improved 3,03% (to 13.1450 ±0.6318%). The IR spectrum of both silica gel showed the same vibration profile and also there were three crystallinity peaks missing on its X-ray diffraction. Regenerated silica gel has the same performance with new silica gel in purification of temulawak's extract: by ethanol has increased 4.08% (14.1947±0.7415%) and 2.93% (13.0447±0.4822) by acetone. In addition, all purification products showed similar TLC profiles. Purification using regenerated silica gel as the adsorbent on vacuum column chromatography has exactly same potential with the new silica gel.

  5. Regenerated silica gel as stationary phase on vacuum column chromatography to purify temulawak’s extracts

    SciTech Connect

    Cahyono, Bambang; Maduwu, Ratna Dewi; Widayat,; Suzery, Meiny

    2015-12-29

    Commercial silica gel only used once by many researchers and affected high cost for purification process, also less support the green chemistry program. This research focused in regeneration silica gel that used purification of temulawak’s extracts (Curcuma xanthorrhiza Roxb) by vacuum column chromatography. Sample extracts (contains 10.1195±0.5971% of curcuminoids) was purified by vacuum column chromatography (pressure: 45 kPa, column: 100mm on length and 16mm on diameter). Ethanol 96% and acetone were compared as eluent. The amount of solvent and yield of curcuminoids used as indicator purification. The silica gel was regenerated with heating in 600°C for 8 hours The silica gels were analyzed by IR spectroscopy and X-ray diffraction. Furthermore, regenerated silica gel was used as the stationary phase in vacuum column chromatography under the same conditions with the previous purification. All the purification experiments were performed in three repetitions. Based on regression equation, y=0.132x+0.0011 (r{sup 2}=0.9997) the yield of curcuminoids on purified products using ethanol as the eluent was improved 4.26% (to 14.3724±0.5749%) and by acetone was improved 3,03% (to 13.1450 ±0.6318%). The IR spectrum of both silica gel showed the same vibration profile and also there were three crystallinity peaks missing on its X-ray diffraction. Regenerated silica gel has the same performance with new silica gel in purification of temulawak’s extract: by ethanol has increased 4.08% (14.1947±0.7415%) and 2.93% (13.0447±0.4822) by acetone. In addition, all purification products showed similar TLC profiles. Purification using regenerated silica gel as the adsorbent on vacuum column chromatography has exactly same potential with the new silica gel.

  6. Development and Validation of an Affinity Chromatography-Protein G Method for IgG Quantification

    PubMed Central

    Paradina Fernández, Lesly; Calvo, Loany; Viña, Lisel

    2014-01-01

    Nimotuzumab, an IgG that recognizes the epidermal growth factor receptor (EGF-R) overexpressed in some tumors, is used in the treatment of advanced head and neck cancer. For the quantification of this protein in cell culture supernatants, protein G-HPLC affinity chromatography is used due to its high affinity and specificity for antibodies of this class. The technique relies on the comparison of the area under the curve of the elution peak of the samples to be evaluated versus to a calibration curve of well-known concentrations and was validated by assessment of its robustness, specificity, repeatability, intermediate precision, accuracy, linearity, limit of detection, limit of quantification, and range. According to results of the study all validation parameters fulfilled the preestablished acceptance criteria and demonstrated the feasibility of the assay for the analysis of samples of cell culture supernatant as well as drug product. PMID:27379284

  7. Preparation and characterization of alkyl methacrylate-based monolithic columns for capillary gas chromatography applications.

    PubMed

    Yusuf, Kareem; Aqel, Ahmad; A L Othman, Zeid; Badjah-Hadj-Ahmed, Ahmed Yacine

    2013-08-02

    Gas chromatography (GC) is considered the least common application of both polymer and silica-based monolithic columns. This study describes the fabrication of alkyl methacrylate monolithic materials for use as stationary phases in capillary gas chromatography. Following the deactivation of the capillary surface with 3-(trimethoxysilyl)propyl methacrylate (TMSM), the monoliths were formed by the co-polymerization of either hexyl methacrylate (HMA) or lauryl methacrylate (LMA) with different percentage of ethylene glycol dimethacrylate (EDMA) in presence of an initiator (azobisisobutyronitrile, AIBN) and a mixture of porogens include 1-propanol, 1,4-butanediol and water. The monoliths were prepared in 500mm length capillaries possessing inner diameters of 250μm. The efficiencies of the monolithic columns for low molecular weight compounds significantly improved as the percentage of crosslinker was increased, because of the greater proportion of pores less than 50nm. The columns containing lower percentages of crosslinker were able to rapidly separate a series of 8 alkane members in 0.7min, but the separation was less efficient for the light alkanes. Columns prepared with the lauryl methacrylate monomer yielded a different morphology for the monolith-interconnected channels. The channels were more branched, which increased the separation time, and unlike the other columns, allowed for temperature programming.

  8. Enantioseparation of methamphetamine by supercritical fluid chromatography with cellulose-based packed column.

    PubMed

    Segawa, Hiroki; Iwata, Yuko T; Yamamuro, Tadashi; Kuwayama, Kenji; Tsujikawa, Kenji; Kanamori, Tatsuyuki; Inoue, Hiroyuki

    2017-02-04

    The enantiomers of methamphetamine were differentiated by supercritical fluid chromatography (SFC) with an enantioselective cellulose-based packed column. The optimization of the chromatographic conditions was achieved by changing column temperature, co-solvent proportion, additive concentration, flow rate and back pressure. In particular, the additive concentration crucially changed the resolution between the enantiomers. After determining the optimized conditions, the enantiomers of methamphetamine were successfully separated. The analytical precision, accuracy and limit of detection were checked by using the authentic standard and seized real samples. We believe that chiral SFC is a promising method for enantioseparation of forensic samples.

  9. Isolation and partial characterization of Bromelia hemisphaerica protease by affinity chromatography.

    PubMed

    Ochoa, N; Agundis, C; Córdoba, F

    1987-01-01

    Hemisphaericin, the protease from Bromelia hemisphaerica fruit juice was isolated by affinity chromatography in one step, using a mercurial sepharose derivative. The enzyme behaves as a single component in immunodifussion, immunoelectrophoresis and polyacrylamide electrophoresis in the presence of SDS and 2-mercaptoethanol. Association and dissociation of active components were evidenced in electrophoresis at pH 3.6 and at pH 8.6. Immunoelectrophoresis analyses also disclosed a certain degree of internal immunological heterogeneity. The results are explained by the presence of an enzyme subunit, of about 8000 daltons, endowed with polymeric properties induced by the pH and oxidative environment.

  10. Rapid and Complete Purification of Acetylcholinesterases of Electric Eel and Erythrocyte by Affinity Chromatography

    PubMed Central

    Berman, Jonathan Dembitz; Young, Michael

    1971-01-01

    Affinity chromatography has been used to purify acetylcholinesterase both from the electric tissue of Electrophorus electricus and from bovine erythrocyte membranes. For this purpose, several specific enzymic inhibitors of each protein were synthesized and joined covalently to an insoluble support resin. AchE is selectively retained by such inhibitor-resins when highly impure solutions are chromatographed upon them. After removal from the resin, both enzymes are electrophoretically homogeneous and they may be recovered in yields of 75% or more. Images PMID:5277092

  11. Actin affinity chromatography in the purification of human, avian and other mammalian plasma proteins binding vitamin D and its metabolites (Gc globulins).

    PubMed Central

    Haddad, J G; Kowalski, M A; Sanger, J W

    1984-01-01

    The human plasma protein binding vitamin D and its metabolites (Gc globulin; group-specific component) has been isolated from human plasma by column affinity chromatography on gels to which monomeric actin was covalently attached. Rabbit skeletal-muscle G-actin was covalently coupled to amino-agarose gels before the application of human plasma. At actin/protein molar ratios of 4-8:1, excellent recovery (approximately 58%) of purified binding protein was achieved. After 0.75 M-NaCl washes, the binding protein was eluted from the columns in 3 M-guanidinium chloride, dialysed and analysed. These eluates contained the binding protein as 34-100% of the total protein, reflecting a 130-fold average purification in this single step. In the presence of Ca2+, gelsolin (another plasma protein that binds actin) was apparently retained by the affinity column, but this was prevented by chelation of plasma Ca2+. The actin affinity step also was effective in the isolation of the binding protein from rat, rabbit and chicken plasma, as indicated by autoradiographs of purified fractions analysed by gel electrophoresis after incubation with 25-hydroxy[26,27-3H]cholecalciferol. Further isolation by hydroxyapatite chromatography yielded a purified binding protein which displayed characteristic binding activity toward vitamin D metabolites and G-actin, and retained its physicochemical features. This brief purification sequence is relatively simple and efficient, and should prove to be useful to investigators studying this interesting plasma protein. Images Fig. 1. Fig. 3. Fig. 4. PMID:6547042

  12. Metal-Organic Framework Thin Films as Stationary Phases in Microfabricated Gas-Chromatography Columns.

    SciTech Connect

    Read, Douglas; Sillerud, Colin Halliday

    2016-01-01

    The overarching goal of this project is to integrate Sandia's microfabricated gas-chromatography ( GC) columns with a stationary phase material that is capable of retaining high-volatility chemicals and permanent gases. The successful integration of such a material with GCs would dramatically expand the repertoire of detectable compounds for Sandia's various microanalysis systems. One such promising class of candidate materials is metal-organic frameworks (MOFs). In this report we detail our methods for controlled deposition of HKUST-1 MOF stationary phases within GC columns. We demonstrate: the chromatographic separation of natural gas; a method for determining MOF film thickness from chromatography alone; and the first-reported GC x GC separation of natural gas -- in general -- let alone for two disparate MOF stationary phases. In addition we determine the fundamental thermodynamic constant for mass sorption, the partition coefficient, for HKUST-1 and several light hydrocarbons and select toxic industrial chemicals.

  13. Optical isomer separation of single-chirality carbon nanotubes using gel column chromatography.

    PubMed

    Liu, Huaping; Tanaka, Takeshi; Kataura, Hiromichi

    2014-11-12

    We report a gel column chromatography method for easily separating the optical isomers (i.e., left- and right-handed structures) of single-chirality carbon nanotubes. This method uses the difference in the interactions of the two isomers of a chiral single-wall carbon nanotube (SWCNT) with an allyl dextran-based gel, which result from the selective interaction of the chiral moieties of the gel with the isomers. Using this technique, we sorted optical isomers of nine distinct (n, m) single-chirality species from HiPco SWCNTs, which is the maximum number of isolable species of SWCNTs reported to date. Because of its advantages of technical simplicity, low cost, and high efficiency, gel column chromatography allows researchers to prepare macroscopic ensembles of single-structure SWCNTs and enables the complete discovery of intrinsic properties of SWCNTs and advances their application.

  14. Size exclusion chromatography of synthetic polymers and biopolymers on common reversed phase and hydrophilic interaction chromatography columns.

    PubMed

    Caltabiano, Anna M; Foley, Joe P; Barth, Howard G

    2016-03-11

    This work describes the applicability of common reversed phase and HILIC columns for size exclusion chromatography of synthetic and natural polymers. Depending on the nature of the solute and column stationary phase, a "non-retention" condition must be created with the aid of the mobile phase to achieve a unique size-based separation in isocratic mode. The various bonded phases show remarkable differences in size separations that are controlled by mobile phase conditions. Polymer-mobile phase and column-mobile phase solvation interactions determine polymer hydrodynamic volume (or solute bulkiness) and polymer-column steric interaction. Solvation interactions in turn depend on polymer, mobile phase and stationary phase polarities. Column-mobile phase solvation interactions determine the structural order of the bonded ligands that can vary from ordered (extended, aligned away from the silica substrate) to disordered (folded, pointing toward the silica substrate). Chain order increases with increased solvent penetration into the bonded phase. Increased chain order reduces pore volume, and therefore decreases the size-separation efficiency of a column. Conversely, decreased chain order increases pore volume and therefore increases the size-separation efficiency. The thermodynamic quality of the mobile phase also plays a significant role in the separation of polymers. "Poor" solvents can significantly reduce the hydrodynamic diameter of a solute and thus change their retention behavior. Medium polarity stationary phases, such as fluoro-phenyl and cyano, exhibit a unique retention behavior. With an appropriate polarity mobile phase, polar and non-polar synthetic polymers of the same molecular masses can be eluted at the same retention volumes.

  15. Signal analysis of NEMS sensors at the output of a chromatography column

    SciTech Connect

    Bertholon, François; Harant, Olivier; Bourlon, Bertrand; Gerfault, Laurent; Grangeat, Pierre; Jutten, Christian

    2015-01-13

    This article introduces a joined Bayesian estimation of gas samples issued from a gas chromatography column (GC) coupled with a NEMS sensor based on Giddings Eyring microscopic molecular stochastic model. The posterior distribution is sampled using a Monte Carlo Markov Chain and Gibbs sampling. Parameters are estimated using the posterior mean. This estimation scheme is finally applied on simulated and real datasets using this molecular stochastic forward model.

  16. High performance mini-gas chromatography-flame ionization detector system based on micro gas chromatography column

    NASA Astrophysics Data System (ADS)

    Zhu, Xiaofeng; Sun, Jianhai; Ning, Zhanwu; Zhang, Yanni; Liu, Jinhua

    2016-04-01

    Monitoring Volatile organic compounds (VOCs) was a very important measure for preventing environmental pollution, therefore, a mini gas chromatography (GC) flame ionization detector (FID) system integrated with a mini H2 generator and a micro GC column was developed for environmental VOC monitoring. In addition, the mini H2 generator was able to make the system explode from far away due to the abandoned use of a high pressure H2 source. The experimental result indicates that the fabricated mini GC FID system demonstrated high repeatability and very good linear response, and was able to rapidly monitor complicated environmental VOC samples.

  17. Optimal model-based design of the twin-column CaptureSMB process improves capacity utilization and productivity in protein A affinity capture.

    PubMed

    Baur, Daniel; Angarita, Monica; Müller-Späth, Thomas; Morbidelli, Massimo

    2016-01-01

    Multi-column chromatographic processes have recently been developed for protein A affinity chromatography to efficiently capture monoclonal antibodies from cell culture supernatant. In this work, the novel twin-column CaptureSMB process was compared to a batch capture process with dual loading flow rate to identify performance gains. As a case study, the isolation of a monoclonal antibody with the Amsphere JWT-203 protein A resin was investigated. Using model based optimization, both processes were optimized and compared over a wide range of operating conditions. A trade-off between productivity and capacity utilization was found, and the resulting pareto-curves showed that CaptureSMB dominates batch, except at very low productivity values. With a feed titer of 1.2 mg mL(-1) , CaptureSMB could reach a productivity of up to 19.5 mg mL(-1) h(-1) experimentally, while maintaining relatively high capacity utilization of 63.8%. On the other hand, at maximum capacity utilization of 95.5%, a productivity of 10.2 mg mL(-1) h(-1) could be reached. This corresponds to a performance improvement with respect batch operation of about 25% in capacity utilization and 40% in productivity, for given yield and purity. CaptureSMB therefore offers a greatly increased performance over batch capture.

  18. Flow rate dependent extra-column variance from injection in capillary liquid chromatography.

    PubMed

    Aggarwal, Pankaj; Liu, Kun; Sharma, Sonika; Lawson, John S; Dennis Tolley, H; Lee, Milton L

    2015-02-06

    Efficiency and resolution in capillary liquid chromatography (LC) can be significantly affected by extra-column band broadening, especially for isocratic separations. This is particularly a concern in evaluating column bed structure using non-retained test compounds. The band broadening due to an injector supplied with a commercially available capillary LC system was characterized from experimental measurements. The extra-column variance from the injection valve was found to have an extra-column contribution independent of the injection volume, showing an exponential dependence on flow rate. The overall extra-column variance from the injection valve was found to vary from 34 to 23 nL. A new mathematical model was derived that explains this exponential contribution of extra-column variance on chromatographic performance. The chromatographic efficiency was compromised by ∼130% for a non-retained analyte because of injection valve dead volume. The measured chromatographic efficiency was greatly improved when a new nano-flow pumping system with integrated injection valve was used.

  19. A new affinity approach to isolate Escherichia coli 6S RNA with histidine-chromatography.

    PubMed

    Martins, R; Queiroz, J A; Sousa, F

    2010-01-01

    6S RNA is an abundant non-coding RNA in Escherichia coli (E. coli), but its function has not been discovered until recently. The first advance on 6S RNA function was the demonstration of its ability to bind the σ(70)-holoenzyme form of RNA polymerase, inhibiting its activity and consequently the transcription process. The growing interest in the investigation of non-coding small RNAs (sRNA) calls for the development of new methods for isolation and purification of RNA. This work presents an optimized RNA extraction procedure and describes a new affinity chromatography method using a histidine support to specifically purify 6S RNA from other E. coli sRNA species. The RNA extraction procedure was optimized, and a high yield was obtained in the separation of sRNA and ribosomal RNA (rRNA) from total RNA (RNAt). This improved method takes advantage of its simplicity and significant cost reduction, since some complex operations have been eliminated. A purification strategy was also developed to separate 6S RNA from an sRNA mixture. Pure RNA can be advantageously obtained using the histidine-affinity chromatography method, aiming at its application to structural or functional studies.

  20. Affinity chromatography reveals RuBisCO as an ecdysteroid-binding protein.

    PubMed

    Uhlik, Ondrej; Kamlar, Marek; Kohout, Ladislav; Jezek, Rudolf; Harmatha, Juraj; Macek, Tomas

    2008-12-22

    The aim of this work was to isolate plant ecdysteroid-binding proteins using affinity chromatography. Ecdysteroids as insect hormones have been investigated thoroughly but their function and the mechanism of action in plants and other organisms is still unknown although ecdysteroids occur in some plants in a relatively large amount. Therefore, 20-hydroxyecdysone was immobilized on a polymeric carrier as a ligand for affinity chromatography in order to isolate plant ecdysteroid-binding proteins from the cytosolic extract of New Zealand spinach (Tetragonia tetragonoides). Non-specifically bound proteins were eluted with a rising gradient of concentration of sodium chloride, and 3% (v/v) acetic acid was used for the elution of the specifically bound proteins. Using this method, ribulose 1,5-bisphosphate carboxylase/oxygenase (RuBisCO) was isolated. The influence of ecdysteroids on RuBisCO was further studied. Our results show that ecdysteroids are able to increase the yield of RuBisCO-mediated reaction in which CO(2) is fixed into organic matter by more than 10%.

  1. Core-Shell Columns in High-Performance Liquid Chromatography: Food Analysis Applications

    PubMed Central

    Preti, Raffaella

    2016-01-01

    The increased separation efficiency provided by the new technology of column packed with core-shell particles in high-performance liquid chromatography (HPLC) has resulted in their widespread diffusion in several analytical fields: from pharmaceutical, biological, environmental, and toxicological. The present paper presents their most recent applications in food analysis. Their use has proved to be particularly advantageous for the determination of compounds at trace levels or when a large amount of samples must be analyzed fast using reliable and solvent-saving apparatus. The literature hereby described shows how the outstanding performances provided by core-shell particles column on a traditional HPLC instruments are comparable to those obtained with a costly UHPLC instrumentation, making this novel column a promising key tool in food analysis. PMID:27143972

  2. A micro gas chromatography column with a micro thermal conductivity detector for volatile organic compound analysis.

    PubMed

    Sun, J H; Cui, D F; Chen, X; Zhang, L L; Cai, H Y; Li, H

    2013-02-01

    In this paper, a micro gas chromatography (μGC) system contained a μGC column and a micro thermal conductivity detector (μTCD) was proposed. In order to reduce the volume of the system, some micro heaters were integrated on the surface and backside of the GC column, which could provide a robust temperature programming capability and rapidly increase the temperature of the μGC column. In addition, a silicon-glass μTCD with four-thermistor thermal conductivity cells that can offer significant advantages over previously reported designs including low dead volume, good thermal isolation, and elimination of the thermal noise was proposed in this paper. Experimental results have indicated that the μGC system with a detection limit of several ppm concentration levels separated and detected the benzene, toluene, and styrene in less than 3 min, and the μGC system also exhibited a good linear response in the test range.

  3. Affinity chromatography of chaperones based on denatured proteins: Analysis of cell lysates of different origin.

    PubMed

    Marchenko, N Yu; Sikorskaya, E V; Marchenkov, V V; Kashparov, I A; Semisotnov, G V

    2016-03-01

    Molecular chaperones are involved in folding, oligomerization, transport, and degradation of numerous cellular proteins. Most of chaperones are heat-shock proteins (HSPs). A number of diseases of various organisms are accompanied by changes in the structure and functional activity of chaperones, thereby revealing their vital importance. One of the fundamental properties of chaperones is their ability to bind polypeptides lacking a rigid spatial structure. Here, we demonstrate that affinity chromatography using sorbents with covalently attached denatured proteins allows effective purification and quantitative assessment of their bound protein partners. Using pure Escherichia coli chaperone GroEL (Hsp60), the capacity of denatured pepsin or lysozyme-based affinity sorbents was evaluated as 1 mg and 1.4 mg of GroEL per 1 ml of sorbent, respectively. Cell lysates of bacteria (E. coli, Thermus thermophilus, and Yersinia pseudotuberculosis), archaea (Halorubrum lacusprofundi) as well as the lysate of rat liver mitochondria were analyzed using affinity carrier with denatured lysozyme. It was found that, apart from Hsp60, other proteins with a molecular weight of about 100, 50, 40, and 20 kDa are able to interact with denatured lysozyme.

  4. Monolith immuno-affinity enrichment liquid chromatography tandem mass spectrometry for quantitative protein analysis of recombinant bovine somatotropin in serum.

    PubMed

    Smits, Nathalie G E; Blokland, Marco H; Wubs, Klaas L; Nessen, Merel A; van Ginkel, Leen A; Nielen, Michel W F

    2015-08-01

    The use of recombinant bovine somatotropin (rbST) to enhance milk production is approved in several countries, but it is prohibited in the European Union. According to EU legislation, it is necessary to confirm positive screening results prior to enforcement. Although adequate screening assays are available nowadays, development of liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory methods to detect low levels of rbST is still a challenge. Here, we present a novel approach using immuno-affinity enrichment on monolithic micro-columns in combination with state-of-the-art ultra-high pressure LC-MS/MS (UHPLC-MS/MS) detection. The developed approach enables detection and confirmation of rbST in serum at a decision limit (CCα) concentration of 0.8 ng mL(-1). Furthermore, the method is easy to handle, robust and reproducible. We successfully applied the confirmatory method to serum samples from rbST treated cows that were found suspect after immunoassay-based screening. The use of rbST could be confirmed over 1 week after treatment, and the developed method demonstrated the sensitivity needed for effective control. Graphical Abstract Graphical summary of the workflow, for serum preparation, enrichment with monolith microcolumns and LC-MS/MS measurement of rbST.

  5. Proteomic analysis of human O {sup 6}-methylguanine-DNA methyltransferase by affinity chromatography and tandem mass spectrometry

    SciTech Connect

    Niture, Suryakant K.; Doneanu, Catalin E.; Velu, Chinavenmeni S.; Bailey, Nathan I.; Srivenugopal, Kalkunte S. . E-mail: Kalkunte.srivenugopal@ttuhsc.edu

    2005-12-02

    Recent evidence suggests that human O {sup 6}-methylguanine-DNA methyltransferase (MGMT), a DNA repair protein that protects the genome against mutagens and accords tumor resistance to many anticancer alkylating agents, may have other roles besides repair. Therefore, we isolated MGMT-interacting proteins from extracts of HT29 human colon cancer cells using affinity chromatography on MGMT-Sepharose. Specific proteins bound to this column were identified by electrospray ionization tandem mass spectrometry and/or Western blotting. These procedures identified >60 MGMT-interacting proteins with diverse functions including those involved in DNA replication and repair (MCM2, PCNA, ORC1, DNA polymerase {delta}, MSH-2, and DNA-dependent protein kinase), cell cycle progression (CDK1, cyclin B, CDK2, CDC7, CDC10, 14-3-3 protein, and p21{sup waf1/cip1}), RNA processing and translation (poly(A)-binding protein, nucleolin, heterogeneous nuclear ribonucleoproteins, A2/B1, and elongation factor-1{alpha}), several histones (H4, H3.4, and H2A.1), and topoisomerase I. The heat shock proteins, HSP-90{alpha} and {beta}, also bound strongly with MGMT. The DNA repair activity of MGMT was greatly enhanced in the presence of interacting proteins or histones. These data, for the first time, suggest that human MGMT is likely to have additional functions, possibly, in sensing and integrating the DNA damage/repair-related signals with replication, cell cycle progression, and genomic stability.

  6. Novel design for centrifugal counter-current chromatography: VI. Ellipsoid column.

    PubMed

    Gu, Dongyu; Yang, Yi; Xin, Xuelei; Aisa, Haji Akber; Ito, Yoichiro

    2015-01-01

    A novel ellipsoid column was designed for centrifugal counter-current chromatography. Performance of the ellipsoid column with a capacity of 3.4 mL was examined with three different solvent systems composed of 1-butanol-acetic acid-water (4:1:5, v/v) (BAW), hexane-ethyl acetate-methanol-0.1 M HCl (1:1:1:1, v/v) (HEMH), and 12.5% (w/w) PEG1000 and 12.5% (w/w) dibasic potassium phosphate in water (PEG-DPP) each with suitable test samples. In dipeptide separation with BAW system, both stationary phase retention (Sf) and peak resolution (Rs) of the ellipsoid column were much higher at 0° column angle (column axis parallel to the centrifugal force) than at 90° column angle (column axis perpendicular to the centrifugal force), where elution with the lower phase at a low flow rate produced the best separation yielding Rs at 2.02 with 27.8% Sf at a flow rate of 0.07 ml/min. In the DNP-amino acid separation with HEMW system, the best results were obtained at a flow rate of 0.05 ml/min with 31.6% Sf yielding high Rs values at 2.16 between DNP-DL-glu and DNP-β-ala peaks and 1.81 between DNP-β-ala and DNP-L-ala peaks. In protein separation with PEG-DPP system, lysozyme and myolobin were resolved at Rs of 1.08 at a flow rate of 0.03 ml/min with 38.9% Sf. Most of those Rs values exceed those obtained from the figure-8 column under similar experimental conditions previously reported.

  7. Pressure Tuning of First Dimension Columns in Comprehensive Two-Dimensional Gas Chromatography.

    PubMed

    Sharif, Khan M; Kulsing, Chadin; Marriott, Philip J

    2016-09-20

    The experimental approach and mechanism of pressure tuning (PT) are introduced for the first stage of a comprehensive two-dimensional gas chromatography (GC × GC) separation. The PT-GC × GC system incorporates a first dimension ((1)D) coupled column ensemble comprising a pair of (1)D columns ((1)D1 and (1)D2) connected via a microfluidic splitter device, allowing variable decompression of carrier gas across each (1)D column, and a conventional (2)D narrow bore column. By variation of junction pressure between the (1)D1 and (1)D2 columns, tunable total (1)D retentions of analytes are readily derived. Separations of a standard mixture comprising a number of different chemical classes (including alkanes, monoaromatics, alcohols, aldehydes, ketones, and esters) and Australian tea tree oil (TTO) were studied as practical examples of the PT-GC × GC system application. This illustrated the change of analyte retention time with experimental conditions depending on void time and retention on the different columns. In addition to void time change, variation of carrier gas relative decompression in the (1)D ensemble leads to tunable contribution of the (1)D1/(1)D2 columns that changes apparent polarity and selectivity of the ensemble. The resulting changes in (1)D elution order further altered elution temperature and thus retention of each analyte on the (2)D column in temperature-programmed GC × GC. 2D orthogonality measurements were then conducted to evaluate overall separation performance under application of different (1)D junction pressure. As a result, distribution and selectivity of particular target compounds, monoterpenes, sesquiterpenes, and oxygenated terpenes in 2D space, and thus orthogonality, could be adequately tuned. This indicates the potential of PT-GC × GC to be applicable for practical sample separation and provides a general approach to tune selectivity of target compounds.

  8. Ultra high pressure liquid chromatography. Column permeability and changes of the eluent properties.

    PubMed

    Gritti, Fabrice; Guiochon, Georges

    2008-04-11

    The behavior of four similar liquid chromatography columns (2.1mm i.d. x 30, 50, 100, and 150 mm, all packed with fine particles, average d(p) approximately 1.7 microm, of bridged ethylsiloxane/silica hybrid-C(18), named BEH-C(18)) was studied in wide ranges of temperature and pressure. The pressure and the temperature dependencies of the viscosity and the density of the eluent (pure acetonitrile) along the columns were also derived, using the column permeabilities and applying the Kozeny-Carman and the heat balance equations. The heat lost through the external surface area of the chromatographic column was directly derived from the wall temperature of the stainless steel tube measured with a precision of +/-0.2 degrees C in still air and +/-0.1 degrees C in the oven compartment. The variations of the density and viscosity of pure acetonitrile as a function of the temperature and pressure was derived from empirical correlations based on precise experimental data acquired between 298 and 373 K and at pressures up to 1.5 kbar. The measurements were made with the Acquity UPLC chromatograph that can deliver a maximum flow rate of 2 mL/min and apply a maximum column inlet pressure of 1038 bar. The average Kozeny-Carman permeability constant of the columns was 144+/-3.5%. The temperature hence the viscosity and the density profiles of the eluent along the column deviate significantly from linear behavior under high-pressure gradients. For a 1000 bar pressure drop, we measured DeltaT=25-30 K, (Deltaeta/eta) approximately 100%, and (Deltarho/rho) approximately 10%. These results show that the radial temperature profiles are never fully developed within 1% for any of the columns, even under still-air conditions. This represents a practical advantage regarding the apparent column efficiency at high flow rates, since the impact of the differential analyte velocity between the column center and the column wall is not maximum. The interpretation of the peak profiles recorded in

  9. Engineering Escherichia coli BL21(DE3) derivative strains to minimize E. coli protein contamination after purification by immobilized metal affinity chromatography.

    PubMed

    Robichon, Carine; Luo, Jianying; Causey, Thomas B; Benner, Jack S; Samuelson, James C

    2011-07-01

    Recombinant His-tagged proteins expressed in Escherichia coli and purified by immobilized metal affinity chromatography (IMAC) are commonly coeluted with native E. coli proteins, especially if the recombinant protein is expressed at a low level. The E. coli contaminants display high affinity to divalent nickel or cobalt ions, mainly due to the presence of clustered histidine residues or biologically relevant metal binding sites. To improve the final purity of expressed His-tagged protein, we engineered E. coli BL21(DE3) expression strains in which the most recurring contaminants are either expressed with an alternative tag or mutated to decrease their affinity to divalent cations. The current study presents the design, engineering, and characterization of two E. coli BL21(DE3) derivatives, NiCo21(DE3) and NiCo22(DE3), which express the endogenous proteins SlyD, Can, ArnA, and (optionally) AceE fused at their C terminus to a chitin binding domain (CBD) and the protein GlmS, with six surface histidines replaced by alanines. We show that each E. coli CBD-tagged protein remains active and can be efficiently eliminated from an IMAC elution fraction using a chitin column flowthrough step, while the modification of GlmS results in loss of affinity for nickel-containing resin. The "NiCo" strains uniquely complement existing methods for improving the purity of recombinant His-tagged protein.

  10. Capillary monolithic titania column for miniaturized liquid chromatography and extraction of organo-phosphorous compounds.

    PubMed

    Abi Jaoudé, Maguy; Randon, Jérôme

    2011-05-01

    A new sol-gel protocol was designed and optimized to produce titanium-dioxide-based columns within confined geometries such as monolithic capillary columns and porous-layer open-tubular columns. A surface pre-treatment of the capillary enabled an efficient anchorage of the monolith to the silica capillary wall during the synthesis. The monolith was further synthesized from a solution containing titanium n-propoxide, hydrochloric acid, N-methylformamide, water, and poly(ethylene oxide) as pore template. The chromatographic application of capillary titania-based columns was demonstrated with the separation of a set of phosphorylated nucleotides as probe molecules using aqueous normal-phase liquid chromatography conditions. Capillary titania monoliths offered a compromise between the high permeability and the important loading capacity needed to potentially achieve miniaturized sample preparations. The specificity of the miniaturized titania monolithic support is illustrated with the specific enrichment of 5'-adenosine mono-phosphate. The monolithic column offered a ten times higher loading capacity of 5'-adenosine mono-phosphate compared with that of the capillary titania porous-layer open-tubular geometry.

  11. Determination of S-carboxymethylcysteine in serum by reversed-phase ion-pair liquid chromatography with column switching following pre-column derivatization with o-phthalaldehyde.

    PubMed

    De Schutter, J A; Van der Weken, G; Van den Bossche, W; de Moerloose, P

    1988-07-15

    A method is described for the determination of S-(carboxymethyl)-L-cysteine in serum. After addition of S-(carboxyethyl)-L-cysteine as internal standard, both compounds are extracted into methanol, converted into fluorescent derivatives with o-phthalaldehyde and quantitatively determined by reversed-phase high-performance liquid chromatography. Chromatography of unwanted amino acid derivatives is avoided by column switching, thereby shortening analysis time and increasing column lifetime. The technique was applied in a study of the bioavailability of S-(carboxymethyl)-L-cysteine after oral administration to humans. The concentration-response curve was linear from 2 to 16 micrograms/ml; mean serum concentrations are reported.

  12. High-performance, static-coated silicon microfabricated columns for gas chromatography.

    PubMed

    Reidy, Shaelah; Lambertus, Gordon; Reece, Jennifer; Sacks, Richard

    2006-04-15

    A procedure is described for the preparation of high-performance etched silicon columns for gas chromatography. Rectangular channels, 150 mum wide by 240 mum deep are fabricated in silicon substrates by gas-phase reactive ion etching. A 0.1-0.2-mum-thick film of dimethyl polysiloxane stationary phase is deposited on the channel walls by filling the channel with a dilute solution in 1:1 n-pentane and dichloromethane and pumping away the solvent. A thermally activated cross-linking agent is used for in situ cross-linking. A 3-m-long microfabricated column generated approximately 12 500 theoretical plates at optimal operating conditions using air as carrier gas. A kinetic model for the efficiency of rectangular cross-section columns is used to evaluate column performance. Results indicate an additional source of gas-phase dispersion beyond longitudinal diffusion and nonequilibrium effects, probably resulting from numerous turns in the gas flow path through the channel. The columns are thermally stable to at least 180 degrees C using air carrier gas. Temperature programming is demonstrated for the boiling point range from n-C5 to n-C12. A 3.0-m-long column heated at 10 degrees C/min obtains a peak capacity of over 100 peaks with a resolution of 1.18 and a separation time of approximately 500 s. With a 0.25-m-long column heated at 30 degrees C/min, a peak capacity of 28 peaks is obtained with a separation time of 150 s. Applications are shown for the analysis of air-phase petroleum hydrocarbons and the high-speed analysis of chemical warfare agent and explosive markers.

  13. A versatile noninvasive method for adsorber quantification in batch and column chromatography based on the ionic capacity.

    PubMed

    Huuk, Thiemo C; Briskot, Till; Hahn, Tobias; Hubbuch, Jürgen

    2016-05-01

    Within the Quality by Design (QbD) framework proposed by the International Conference on Harmonisation (ICH), high-throughput process development (HTPD) and mechanistic modeling are of outstanding importance for future biopharmaceutical chromatography process development. In order to compare the data derived from different column scales or batch chromatographies, the amount of adsorber has to be quantified with the same noninvasive method. Similarly, an important requirement for the implementation of mechanistic modeling is the reliable determination of column characteristics such as the ionic capacity Λ for ion-exchange chromatography with the same method at all scales and formats. We developed a method to determine the ionic capacity in column and batch chromatography, based on the adsorption/desorption of the natural, uv-detectable amino acid histidine. In column chromatography, this method produces results comparable to those of classical acid-base titration. In contrast to acid-base titration, this method can be adapted to robotic batch chromatographic experiments. We are able to convert the adsorber volumes in batch chromatography to the equivalent volume of a compressed column. In a case study, we demonstrate that this method increases the quality of SMA parameters fitted to batch adsorption isotherms, and the capability to predict column breakthrough experiments. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:666-677, 2016.

  14. High resolution capillary column development for selective separations in gas chromatography

    SciTech Connect

    Przybyciel, M.

    1985-01-01

    A review of techniques for the preparation of high resolution capillary columns for gas chromatography is presented. Surface roughing, surface deactivation, stationary phase coating, and stationary phase crosslinking are discussed. Criteria for the selection of GC stationary phases and procedures for column evaluation are presented. A method is proposed for the isolation and determination of crude oil contamination in tropical plants and sediments. The method uses Florisil (TM) chromatography for the simultaneous clean-up and fractionation of aliphatic and aromatic hydrocarbons. Crosslinked SE-54 fused silica capillary columns prepared in our laboratory were employed for all GC separations. Mass spectrometry was used to help locate and identify specific oil components despite the intense background of the chromatogram. Crude oil components were identified in extracts of mangrove plant samples collected from the Peck Slip oil spill site at Media Munda, Puerto Rico. Crude oil components were also identified in sediment samples from controlled oil spill of Prudhoe Bay oil at Laguna de Chiriqui, Panama.

  15. Identification of the Cardiac Beta-Adrenergic Receptor Protein: Solubilization and Purification by Affinity Chromatography

    PubMed Central

    Lefkowitz, Robert J.; Haber, Edgar; O'Hara, Donald

    1972-01-01

    A protein that binds catecholamines with a specificity parallel to that of their in vivo effects on cardiac contractility (isoproterenol > epinephrine or norepinephrine > dopamine > dihydroxyphenylalanine) was solubilized from a microsomal fraction of canine ventricular myocardium. The binding protein was purified 500 to 800-fold by solubilization and subsequent affinity chromatography with conjugates of norepinephrine linked to agarose beads. Purified β-adrenergic binding protein exists in two forms, corresponding to molecular weights of 40,000 and 160,000. The purified material has a single association constant, 2.3 × 105 liters/mol (as compared to two association constants, 107 and 106 liters/mol, for the binding protein in particulate form) but retains the identical binding specificity for β-adrenergic drugs and antagonists. Images PMID:4507606

  16. Protein Affinity Chromatography with Purified Yeast DNA Polymerase α Detects Proteins that Bind to DNA Polymerase

    NASA Astrophysics Data System (ADS)

    Miles, Jeff; Formosa, Tim

    1992-02-01

    We have overexpressed the POL1 gene of the yeast Saccharomyces cerevisiae and purified the resulting DNA polymerase α polypeptide in an apparently intact form. We attached the purified DNA polymerase covalently to an agarose matrix and used this matrix to chromatograph extracts prepared from yeast cells. At least six proteins bound to the yeast DNA polymerase α matrix that did not bind to a control matrix. We speculate that these proteins might be DNA polymerase α accessory proteins. Consistent with this interpretation, one of the binding proteins, which we have named POB1 (polymerase one binding), is required for normal chromosome transmission. Mutations in this gene cause increased chromosome loss and an abnormal cell morphology, phenotypes that also occur in the presence of mutations in the yeast α or δ polymerase genes. These results suggest that the interactions detected by polymerase affinity chromatography are biologically relevant and may help to illuminate the architecture of the eukaryotic DNA replication machinery.

  17. Contamination of ribosome inactivating proteins with ribonucleases, separated by affinity chromatography on red sepharose.

    PubMed

    Wang, H X; Ng, T B; Cheng, C H K; Fong, W P

    2003-05-01

    Three preparations of type 1 ribosome inactivating proteins (RIPs), namely, agrostin, saporin, and luffin, were subjected to affinity chromatography on Red Sepharose and eluted with a linear concentration gradient of NaCl in 10 mM Tris-HCl buffer (pH 7.4). The eluate was assayed for ability to inhibit translation in a cell-free rabbit reticulocyte lysate system which measures RIP activity, and for ability to hydrolyze yeast transfer RNA which measures RNase activity. It was found that, in all three RIP preparations, the peak of RIP activity, which coincided with the peak of absorbance at 280 nm, was eluted earlier than the peak of RNase activity. It appears that RNase is a possible contaminant of ribosome inactivating protein preparations and that this contamination can be minimized by using Red Sepharose.

  18. A recombinant envelope protein from Dengue virus purified by IMAC is bioequivalent with its immune-affinity chromatography purified counterpart.

    PubMed

    Hermida, L; Rodríguez, R; Lazo, L; López, C; Márquez, G; Páez, R; Suárez, C; Espinosa, R; García, J; Guzmán, G; Guillén, G

    2002-03-28

    Semi-purified DEN-4 envelope protein, obtained in Pichia pastoris, was capable of generating neutralising and protecting antibodies after immunisation in mice. Here we compared two purification processes of this recombinant protein using two chromatographic steps: immune-affinity chromatography and immobilised metal ion adsorption chromatography (IMAC). The protein purified by both methods produced functional antibodies reflected by titres of haemagglutination inhibition and neutralisation. IMAC could be used as an alternative for high scale purification.

  19. Phenylboronic acid-salicylhydroxamic acid bioconjugates. 2. Polyvalent immobilization of protein ligands for affinity chromatography.

    PubMed

    Wiley, J P; Hughes, K A; Kaiser, R J; Kesicki, E A; Lund, K P; Stolowitz, M L

    2001-01-01

    Phenylboronic acid bioconjugates prepared from alkaline phosphatase by reaction with either 2,5-dioxopyrrolidinyl 3-[N-[3-(1,3,2-dioxaboran-2-yl)phenyl]carbamoyl]propanoate (PBA-XX-NHS) or 2,5-dioxopyrrolidinyl 6-[[3,5-di-(1,3,2-dioxaboran-2-yl)phenyl]carbonylamino]hexanoate (PDBA-X-NHS) were compared with respect to the efficiency with which they were immobilized on salicylhydroxamic acid-modified Sepharose (SHA-X-Sepharose) by boronic acid complex formation. When immobilized on moderate capacity SHA-X-Sepharose (5.4 micromol of SHA/mL of gel), PDBA-alkaline phosphatase conjugates were shown to be stable with respect to both the alkaline (pH 11.0) and acidic (pH 2.5) buffers utilized to recover anti-alkaline phosphatase during affinity chromatography. Boronic acid complex formation was compared to covalent immobilization of alkaline phosphatase on Affi-Gel 10 and Affi-Gel 15. PDBA-AP.SHA-X-Sepharose was shown to afford superior performance to both Affi-Gel 10 and Affi-Gel 15 with respect to immobilization of alkaline phosphatase, retention of anti-alkaline phosphatase and recovery of anti-alkaline phosphatase under alkaline conditions. High capacity SHA-X-Sepharose (> or = 7 micromol of SHA/mL of gel) was shown to afford superior performance to moderate capacity SHA-X-Sepharose (4.5 micromol of SHA/mL of gel) with respect to stability at pH 11.0 and pH 2.5 when a PDBA-alphaHuman IgG conjugate with a low incorporation ratio of only 1.5:1 was immobilized on SHA-X-Sepharose and subsequently utilized for affinity chromatography of Human IgG. The results are interpreted in terms of either a bivalent or trivalent interaction involving boronic acid complex formation.

  20. Single-Step Purification of Monomeric l-Selectin via Aptamer Affinity Chromatography

    PubMed Central

    Kuehne, Christian; Wedepohl, Stefanie; Dernedde, Jens

    2017-01-01

    l-selectin is a transmembrane receptor expressed on the surface of white blood cells and responsible for the tethering of leukocytes to vascular endothelial cells. This initial intercellular contact is the first step of the complex leukocyte adhesion cascade that ultimately permits extravasation of leukocytes into the surrounding tissue in case of inflammation. Here we show the binding of a soluble histidine tagged l-selectin to a recently described shortened variant of an l-selectin specific DNA aptamer with surface plasmon resonance. The high specificity of this aptamer in combination with its high binding affinity of ~12 nM, allows for a single-step protein purification from cell culture supernatants. In comparison to the well-established Ni-NTA based technology, aptamer affinity chromatography (AAC) was easier to establish, resulted in a 3.6-fold higher protein yield, and increased protein purity. Moreover, due to target specificity, the DNA aptamer facilitated binding studies directly from cell culture supernatant, a helpful characteristic to quickly monitor successful expression of biological active l-selectin. PMID:28125045

  1. Purification of peroxidase from red cabbage (Brassica oleracea var. capitata f. rubra) by affinity chromatography.

    PubMed

    Somtürk, Burcu; Kalın, Ramazan; Özdemir, Nalan

    2014-08-01

    Peroxidase was purified in a single step using 4-amino benzohydrazide affinity chromatography from red cabbage (Brassica oleracea var. capitata f. rubra), and some important biochemical characteristics of the purified enzyme were determined. The enzyme, with a specific activity of 3,550 EU/mg protein, was purified 120.6-fold with a yield of 2.9% from the synthesized affinity matrix. The molecular weight of the enzyme was found to be 69.3 kDa by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). The enzyme exhibited maximum activity at pH 7.0 and 30 °C. For guaiacol substrate, the K m and V max values were found as 0.048 mM and 1.46 EU/mL/min, respectively. Additionally, the IC50 and K i values for 4-amino benzohydrazide were calculated to be 1.047 and 0.702±0.05 mM, respectively, and 4-amino benzohydrazide showed noncompetitive inhibition.

  2. Using affinity chromatography to engineer and characterize pH-dependent protein switches.

    PubMed

    Sagermann, Martin; Chapleau, Richard R; DeLorimier, Elaine; Lei, Margarida

    2009-01-01

    Conformational changes play important roles in the regulation of many enzymatic reactions. Specific motions of side chains, secondary structures, or entire protein domains facilitate the precise control of substrate selection, binding, and catalysis. Likewise, the engineering of allostery into proteins is envisioned to enable unprecedented control of chemical reactions and molecular assembly processes. We here study the structural effects of engineered ionizable residues in the core of the glutathione-S-transferase to convert this protein into a pH-dependent allosteric protein. The underlying rational of these substitutions is that in the neutral state, an uncharged residue is compatible with the hydrophobic environment. In the charged state, however, the residue will invoke unfavorable interactions, which are likely to induce conformational changes that will affect the function of the enzyme. To test this hypothesis, we have engineered a single aspartate, cysteine, or histidine residue at a distance from the active site into the protein. All of the mutations exhibit a dramatic effect on the protein's affinity to bind glutathione. Whereas the aspartate or histidine mutations result in permanently nonbinding or binding versions of the protein, respectively, mutant GST50C exhibits distinct pH-dependent GSH-binding affinity. The crystal structures of the mutant protein GST50C under ionizing and nonionizing conditions reveal the recruitment of water molecules into the hydrophobic core to produce conformational changes that influence the protein's active site. The methodology described here to create and characterize engineered allosteric proteins through affinity chromatography may lead to a general approach to engineer effector-specific allostery into a protein structure.

  3. Rapid, economical qualitative method for separation of aflatoxins B-1, B-2 & G-1, G-2 by dry column chromatography.

    PubMed

    Megalla, S E

    1983-12-01

    A good correlation of four components of aflatoxins was accomplished by using the dry column chromatography method. The decolorization process of interfering substances, by 0.01 N KOH and defatting the extract with petroleum ether yields a clean residue for DCC separation. It is clear that the dry column chromatography is a very simple and time-saving procedure for separation of aflatoxins. DCC columns are more economical than precoated 'thick layer' preparative plates and, in DCC, no large developing tanks need to be used. Hazards associated with the use of large volumes of flammable solvents are greatly reduced.

  4. Application of Pre-Column Labeling Liquid Chromatography for Canine Plasma-Free Amino Acid Analysis

    PubMed Central

    Azuma, Kazuo; Hirao, Yoshiko; Hayakawa, Yoshihiro; Murahata, Yusuke; Osaki, Tomohiro; Tsuka, Takeshi; Imagawa, Tomohiro; Okamoto, Yoshiharu; Ito, Norihiko

    2016-01-01

    Plasma-free amino acid (PFAA) levels are a useful metric for diagnosing cancer and providing a prognosis. However, the use of analysis of PFAA levels has been limited in the veterinary medicine field. We addressed the application of liquid chromatography (LC) using a pre-column labeling technique for analysis of canine PFAA levels. This method significantly shortened the analysis time relative to conventional methods. No diurnal fluctuations were detected at 9:00 AM in most PFAA levels, and food intake increased the levels of some PFAAs, including valine, leucine, tyrosine, phenylalanine, and proline. These results indicate that LC with pre-column labeling is useful for measuring canine PFAA levels, for which time of day and interval after food intake must be taken into consideration. PMID:26771650

  5. Electrochemically-modulated liquid chromatography (EMLC): Column design, retention processes, and applications

    SciTech Connect

    Ting, En -Yi

    1997-10-08

    This work describes the continued development of a new separation technique, electrochemically-modulated liquid chromatography (EMLC), from column design, retention mechanisms to pharmaceutical applications. The introduction section provides a literature review of the technique as well as a brief overview of the research in each of the chapters. This section is followed by four chapters which investigate the issues of EMLC column design, the retention mechanism of monosubstituted aromatic compounds, and the EMLC-based applications to two important classes of pharmaceutical compounds (i.e., corticosteroids and benzodiazepines). These four sections have been removed to process separately for inclusion on the database. The dissertation concludes with a general summary, a prospectus, and a list of references cited in the General Introduction. 32 refs.

  6. Determination of fungicide residues in fruits by coupled-column liquid chromatography.

    PubMed

    Zamora, Tatiana; Hidalgo, Carmen; López, Francisco J; Hernández, Félix

    2004-06-01

    Coupled-column liquid chromatography with fluorescence detection was applied to the determination of o-phenylphenol and bitertanol residues in orange and banana fruits. After extraction with a mixture of acetone, dichloromethane-petroleum ether, and ethyl acetate, an extract aliquot of 100 microL was injected directly without any additional clean-up into the chromatographic system using two reversed phase C18 coupled columns. The LC-LC approach allowed automated sample clean up of the vegetal extracts, leading to a simple and rapid analytical procedure, with limits of quantification between 0.01 and 0.05 mg kg(-1). Recovery experiments performed on orange and banana samples fortified at different concentrations (0.01 - 4 mg kg(-1)) gave average recoveries between 70 and 113% with relative standard deviations lower than 15%. The procedure developed was finally applied to orange and banana samples from different geographical locations and the results were confirmed by GC-MS.

  7. Kinetic efficiency of polar monolithic capillary columns in high-pressure gas chromatography.

    PubMed

    Kurganov, A A; Korolev, A A; Shiryaeva, V E; Popova, T P; Kanateva, A Yu

    2013-11-08

    Poppe plots were used for analysis of kinetic efficiency of monolithic sorbents synthesized in quartz capillaries for utilization in high-pressure gas chromatography. Values of theoretical plate time and maximum number of theoretical plates occurred to depend significantly on synthetic parameters such as relative amount of monomer in the initial polymerization mixture, temperature and polymerization time. Poppe plots let one to find synthesis conditions suitable either for high-speed separations or for maximal efficiency. It is shown that construction of kinetic Poppe curves using potential Van Deemter data demands compressibility of mobile phase to be taken into consideration in the case of gas chromatography. Model mixture of light hydrocarbons C1 to C4 was then used for investigation of influence of carrier gas nature on kinetic efficiency of polymeric monolithic columns. Minimal values of theoretical plate times were found for CO2 and N2O carrier gases.

  8. Impact of reversed phase column pairs in comprehensive two-dimensional liquid chromatography.

    PubMed

    Allen, Robert C; Barnes, Brian B; Haidar Ahmad, Imad A; Filgueira, Marcelo R; Carr, Peter W

    2014-09-26

    A major issue in optimizing the resolving power of two-dimensional chromatographic separations is the choice of the two phases so as to maximize the distribution of the analytes over the separation space. In this work, we studied the choice of appropriate reversed phases to use in on-line comprehensive two-dimensional liquid chromatography (LC×LC). A set of four chemically different conventional bonded reversed phases was used in the first dimension. The second dimension column was either a conventional bonded C18 phase or a carbon-clad phase (CCP). The LC×LC chromatograms and contour plots were all rather similar indicating that the selectivities of the two phases were also similar regardless of the reverse phase column used in the first dimension. Further, the spatial coverage seen with all four first dimension stationary phases when paired with a second dimension C18 phase were low and the retention times were strongly correlated. However, when the C18 column was replaced with the CCP column much improved separations were observed with higher spatial coverages, greater orthogonalities and significant increases in the number of observed peaks.

  9. Ionic liquid-based zwitterionic organic polymer monolithic column for capillary hydrophilic interaction chromatography.

    PubMed

    Wang, Tingting; Chen, Yihui; Ma, Junfeng; Zhang, Xiaodan; Zhang, Lihua; Zhang, Yukui

    2015-08-21

    In the current study, a novel ionic liquid-based zwitterionic organic polymer monolithic column was developed by copolymerizing 1-vinyl-3-(butyl-4-sulfonate) imidazolium, acrylamide and N,N'-methylenebisacrylamide in a quaternary porogenic solvent consisting of formamide, dimethyl sulphoxide, polyethylene glycol 8000 and polyethylene glycol 10,000 for capillary hydrophilic interaction chromatography. The monolithic stationary phase was optimized by adjusting the amount of monomer in the polymerization solution along with the composition of porogenic solvent. The optimized monolith exhibited excellent selectivity and favorable retention for nucleosides and benzoic acid derivatives. The primary factors affecting the separation efficiency of the monolithic column (including acetonitrile content, pH, and buffer salt concentration in the mobile phase) have been thoroughly evaluated. Excellent reproducibility of the retention times for five nucleosides was achieved, with relative standard deviations of run-to-run (n = 3), column-to-column (n = 3) and batch-to-batch (n = 3) in the range of 0.18-0.48%, 2.33-4.20% and 3.07-6.50%, respectively.

  10. Capture chromatography for Mo-99 recovery from uranyl sulfate solutions: minimum-column-volume design method.

    PubMed

    Ling, Lei; Chung, Pei-Lun; Youker, Amanda; Stepinski, Dominique C; Vandegrift, George F; Wang, Nien-Hwa Linda

    2013-09-27

    Molybdenum-99 (Mo-99), generated from the fission of Uranium-235 (U-235), is the radioactive parent of the most widely used medical isotope, technetium-99m (Tc-99m). An efficient, robust, low-pressure process is developed for recovering Mo-99 from uranyl sulfate solutions. The minimum column volume and the maximum column length for required yield, pressure limit, and loading time are determined using a new graphical method. The method is based on dimensionless groups and intrinsic adsorption and diffusion parameters, which are estimated using a small number of experiments and simulations. The design is tested with bench-scale experiments with titania columns. The results show a high capture yield and a high stripping yield (95±5%). The design can be adapted to changes in design constraints or the variations in feed concentration, feed volume, or material properties. The graph shows clearly how the column utilization is affected by the required yield, loading time, and pressure limit. The cost effectiveness of various sorbent candidates can be evaluated based on the intrinsic parameters. This method can be used more generally for designing other capture chromatography processes.

  11. Separation of nucleotides by hydrophilic interaction chromatography using the FRULIC-N column.

    PubMed

    Padivitage, Nilusha L T; Dissanayake, Milan K; Armstrong, Daniel W

    2013-11-01

    A stationary phase composed of silica-bonded cyclofructan 6 (FRULIC-N) was evaluated for the separation of four cyclic nucleotides, six nucleoside monophosphates, four nucleoside diphosphates, and five nucleoside triphosphates via hydrophilic interaction chromatography (HILIC) in both isocratic and gradient conditions. The gradient conditions gave significantly better separations by narrowing peak widths. Sixteen out of nineteen nucleotides were baseline separated on the FRULIC-N column in one run. Unlike other known HILIC stationary phases, there can be dual-retention mechanisms unique to this media. Traditional hydrogen bonding/dipolar interactions can be supplemented by dynamic ion interaction effects for anionic analytes. This occurs because the FRULIC-N stationary phase is able to bind certain buffer cations. The extent of the ion interaction is tunable, in comparison to stationary phases with embedded charged groups, where the inherent ionic properties are fixed. The best mobile phase conditions were determined by varying the organic modifier (acetonitrile) content, as well as salt type/concentration and electrolyte pH. The thermodynamic characteristic of the FRULIC-N column was investigated by evaluating the column temperature effect on retention and utilizing van't Hoff plots. This study shows that there is a greater entropic contribution for the retention of nucleotide di and triphosphates, whereas there is a greater enthalphic contribution for the cyclic nucleotides with the FRULIC-N column.

  12. Blind column selection protocol for two-dimensional high performance liquid chromatography.

    PubMed

    Burns, Niki K; Andrighetto, Luke M; Conlan, Xavier A; Purcell, Stuart D; Barnett, Neil W; Denning, Jacquie; Francis, Paul S; Stevenson, Paul G

    2016-07-01

    The selection of two orthogonal columns for two-dimensional high performance liquid chromatography (LC×LC) separation of natural product extracts can be a labour intensive and time consuming process and in many cases is an entirely trial-and-error approach. This paper introduces a blind optimisation method for column selection of a black box of constituent components. A data processing pipeline, created in the open source application OpenMS®, was developed to map the components within the mixture of equal mass across a library of HPLC columns; LC×LC separation space utilisation was compared by measuring the fractional surface coverage, fcoverage. It was found that for a test mixture from an opium poppy (Papaver somniferum) extract, the combination of diphenyl and C18 stationary phases provided a predicted fcoverage of 0.48 and was matched with an actual usage of 0.43. OpenMS®, in conjunction with algorithms designed in house, have allowed for a significantly quicker selection of two orthogonal columns, which have been optimised for a LC×LC separation of crude extractions of plant material.

  13. Simple, specific analysis of organophosphorus and carbamate pesticides in sediments using column extraction and gas chromatography

    USGS Publications Warehouse

    Belisle, A.A.; Swineford, D.M.

    1988-01-01

    A simple, specific procedure was developed for the analysis of organophosphorus and carbamate pesticides in sediment. The wet soil was mixed with anhydrous sodium sulfate to bind water and the residues were column extracted in acetone:methylene chloride (1:l,v/v). Coextracted water was removed by additional sodium sulfate packed below the sample mixture. The eluate was concentrated and analyzed directly by capillary gas chromatography using phosphorus and nitrogen specific detectors. Recoveries averaged 93 % for sediments extracted shortly after spiking, but decreased significantly as the samples aged.

  14. Inverse gas chromatography. V - Computer simulation of diffusion processes on the column

    NASA Technical Reports Server (NTRS)

    Hattam, Paul; Munk, Petr

    1988-01-01

    The elution behavior of low molecular weight probes on inverse gas chromatography (IGC) columns is simulated using a computer. The IGC model is based on a polymer stationary phase of uniform thickness with a nonnegligible resitance to probe penetration. Three characteristic numbers are found to determine the whole process: Z(p) characterizing the distribution of the probe between phases, Z(f) describing the diffusion in the polymer phase, and Z(g) related to diffusion in the gaseous phase. For situations when Z(p)/Z(f) is less than 2, the standard evaluation procedures are virtually useless. The actual behavior of such systems is described.

  15. Stationary phase optimized selectivity liquid chromatography: Basic possibilities of serially connected columns using the "PRISMA" principle.

    PubMed

    Nyiredy, Sz; Szucs, Zoltán; Szepesy, L

    2007-07-20

    A new procedure (stationary phase optimized selectivity liquid chromatography: SOS-LC) is described for the optimization of the HPLC stationary phase, using serially connected columns and the principle of the "PRISMA" model. The retention factors (k) of the analytes were determined on three different stationary phases. By use of these data the k values were predicted applying theoretically combined stationary phases. These predictions resulted in numerous intermediate theoretical separations from among which only the optimal one was assembled and tested. The overall selectivity of this separation was better than that of any individual base stationary phase. SOS-LC is independent of the mechanism and the scale of separation.

  16. Separation of TFIIIC into two functional components by sequence specific DNA affinity chromatography.

    PubMed Central

    Dean, N; Berk, A J

    1987-01-01

    Recently, it has been shown that mammalian transcription factor IIIC (TFIIIC) activity can be separated by anion exchange FPLC chromatography into two functional components (1), both of which are required for transcription of tRNA and the adenovirus VA RNA genes. Here we show that these two functional components, designated TFIIIC1 and TFIIIC2, can also be separated by sequence specific DNA affinity chromatography. These results confirm the observation that TFIIIC can be fractionated into two components, which are both required for transcription of VA I and tRNA genes in vitro. Thus in the mammalian reconstituted system, a minimum of three proteins, in addition to RNA polymerase III, are required for the transcription of the VA and tRNA genes in vitro. The DNA binding component, TFIIIC2, binds specifically to the 3' segment of the internal promoter (the B block), demonstrated by its ability to protect this region from digestion by DNase I. TFIIIC2 is the limiting, titratable component in the phosphocellulose C fraction required for the formation of a stable pre-initiation complex on the VAI RNA gene in vitro, as demonstrated with a template competition and rescue assay. Images PMID:3697084

  17. Virus-binding proteins recovered from bacterial culture derived from activated sludge by affinity chromatography assay using a viral capsid peptide.

    PubMed

    Sano, Daisuke; Matsuo, Takahiro; Omura, Tatsuo

    2004-06-01

    The contamination of water environments by pathogenic viruses has raised concerns about outbreaks of viral infectious diseases in our society. Because conventional water and wastewater treatment systems are not effective enough to inactivate or remove pathogenic viruses, a new technology for virus removal needs to be developed. In this study, the virus-binding proteins (VBPs) in a bacterial culture derived from activated sludge were successfully recovered. The recovery of VBPs was achieved by applying extracted crude proteins from a bacterial culture to an affinity column in which a custom-made peptide of capsid protein from the poliovirus type 1 (PV1) Mahoney strain (H(2)N-DNPASTTNKDKL-COOH) was immobilized as a ligand. VBPs exhibited the ability to adsorb infectious particles of PV1 Sabin 1 as determined by enzyme-linked immunosorbent assay. The evaluation of surface charges of VBPs with ion-exchange chromatography found that a majority of VBP molecules had a net negative charge under the conditions of affinity chromatography. On the other hand, a calculated isoelectric point implied that the viral peptide in the affinity column was also charged negatively. As a result, the adsorption of the VBPs to the viral peptide in the affinity column occurred with a strong attractive force that was able to overcome the electrostatic repulsive force. Two-dimensional electrophoresis revealed that the isolated VBPs include a number of proteins, and their molecular masses were widely distributed but smaller than 100 kDa. Amino acid sequences of N termini of five VBPs were determined. Homology searches for the N termini against all protein sequences in the National Center for Biotechnology Information (NCBI) database showed that the isolated VBPs in this study were newly discovered proteins. These VBPs that originated with bacteria in activated sludge might be stable, because they are existing in the environment of wastewater treatments. Therefore, a virus removal technology

  18. Proteomic analysis of copper-binding proteins in excess copper-stressed rice roots by immobilized metal affinity chromatography and two-dimensional electrophoresis.

    PubMed

    Song, Yufeng; Zhang, Hongxiao; Chen, Chen; Wang, Guiping; Zhuang, Kai; Cui, Jin; Shen, Zhenguo

    2014-04-01

    Copper (Cu) is an essential micronutrient required for plant growth and development. However, excess Cu can inactivate and disturb protein structure as a result of unavoidable binding to proteins. To understand better the mechanisms involved in Cu toxicity and tolerance in plants, we developed a new immobilized metal affinity chromatography (IMAC) method for the separation and isolation of Cu-binding proteins extracted from roots of rice seedling exposed to excess Cu. In our method, IDA-Sepharose or EDDS-Sepharose column (referred as pre-chromatography) and Cu-IDA-Sepharose column (referred as Cu-IMAC) were connected in tandem. Namely, protein samples were pre-chromatographed with IDA-Sepharose column to removal metal ions, then protein solution was flowed into Cu-IMAC column for enriching Cu-binding proteins in vitro. Compared with the control (Cu-IMAC without any pre-chromatography), IDA-Sepharose pre-chromatography method markedly increased yield of the Cu-IMAC-binding proteins, and number of protein spots and the abundance of 40 protein spots on two-dimensional electrophoresis (2-DE) gels. Thirteen protein spots randomly selected from 2-DE gel and 11 proteins were identified using MALDI-TOF-TOF MS. These putative Cu-binding proteins included those involved in antioxidant defense, carbohydrate metabolism, nucleic acid metabolism, protein folding and stabilization, protein transport and cell wall synthesis. Ten proteins contained one or more of nine putative metal-binding motifs reported by Smith et al. (J Proteome Res 3:834-840, 2004) and seven proteins contained one or two of top six motifs reported by Kung et al. (Proteomics 6:2746-2758, 2006). Results demonstrated that more proteins specifically bound with Cu-IMAC could be enriched through removal of metal ions from samples by IDA-Sepharose pre-chromatography. Further studies are needed on metal-binding characteristics of these proteins in vivo and the relationship between Cu ions and protein biological

  19. Fractionation of the genetic variants of human alpha 1-acid glycoprotein in the native form by chromatography on an immobilized copper(II) affinity adsorbent. Heterogeneity of the separate variants by isoelectrofocusing and by concanavalin A affinity chromatography.

    PubMed

    Hervé, F; Gomas, E; Duché, J C; Tillement, J P

    1993-05-19

    Fractionation of the three main genetic variants (F1, S and A) of human alpha 1-acid glycoprotein (AAG), in their native (sialylated) form, by chromatography on immobilized copper(II) affinity adsorbent was investigated. This chromatographic method had been previously developed to fractionate the desialylated protein variants. For that purpose, the three main AAG phenotypes samples (F1S/A, F1/A and S/A), which had been previously isolated from individual human plasma samples, and an AAG sample from commercial source (a mixture of the phenotypes) were used in the native form. Affinity chromatography of these different samples on an iminodiacetate Sepharose-copper(II) gel at pH 7 resolved two protein peaks, irrespective of the origin of the native AAG sample used. The unbound peak 1 was found to consist of the F1, the S or both variants, depending on the phenotype of the AAG sample used in the chromatography. The bound peak 2 was found to consist of the A variant in a pure form. The fractionation results obtained with native AAG were found to be the same as those originally yielded by the desialylated protein. However, comparison of the interactions of native and desialylated AAG with immobilized copper(II) ions, using an affinity chromatographic method and a non-chromatographic equilibrium binding technique, respectively, showed that desialylation increased the non-specific interactions of the protein with immobilized copper(II) ions. The AAG variants were not fractionated when affinity chromatography was performed using immobilized zinc, nickel or cobalt(II) ions, instead of copper. After purification of each variant in the sialylated form (F1, S and A), their respective heterogeneity was studied by analytical isoelectrofocusing with carrier ampholytes in the pH range 2.5-4.5. In addition, the lectin-binding behaviour of the separate sialylated AAG variants was investigated by affinity chromatography on immobilized concanavalin A.

  20. New family of glutathionyl-biomimetic ligands for affinity chromatography of glutathione-recognising enzymes.

    PubMed

    Melissis, S C; Rigden, D J; Clonis, Y D

    2001-05-11

    Three anthraquinone glutathionyl-biomimetic dye ligands, comprising as terminal biomimetic moiety glutathione analogues (glutathionesulfonic acid, S-methyl-glutathione and glutathione) were synthesised and characterised. The biomimetic ligands were immobilised on agarose gel and the affinity adsorbents, together with a nonbiomimetic adsorbent bearing Cibacron Blue 3GA, were studied for their purifying ability for the glutathione-recognising enzymes, NAD+-dependent formaldehyde dehydrogenase (FaDH) from Candida boidinii, NAD(P)+-dependent glutathione reductase from S. cerevisiae (GSHR) and recombinant maize glutathione S-transferase I (GSTI). All biomimetic adsorbents showed higher purifying ability for the target enzymes compared to the nonbiomimetic adsorbent, thus demonstrating their superior effectiveness as affinity chromatography materials. In particular, the affinity adsorbent comprising as terminal biomimetic moiety glutathionesulfonic acid (BM1), exhibited the highest purifying ability for FaDH and GSTI, whereas, the affinity adsorbent comprising as terminal biomimetic moiety methyl-glutathione (BM2) exhibited the highest purifying ability for GSHR. The BM1 adsorbent was integrated in a facile two-step purification procedure for FaDH. The purified enzyme showed a specific activity equal to 79 U/mg and a single band after sodium dodecylsulfate-polyacrylamide gel electrophoresis analysis. Molecular modelling was employed to visualise the binding of BM1 with FaDH, indicating favourable positioning of the key structural features of the biomimetic dye. The anthraquinone moiety provides the driving force for the correct positioning of the glutathionyl-biomimetic moiety in the binding site. It is located deep in the active site cleft forming many favourable hydrophobic contacts with hydrophobic residues of the enzyme. The positioning of the glutathione-like biomimetic moiety is primarily achieved by the strong ionic interactions with the Zn2+ ion of FaDH and Arg

  1. Comprehensive profiling of ribonucleosides modification by affinity zirconium oxide-silica composite monolithic column online solid-phase microextraction - Mass spectrometry analysis.

    PubMed

    Jiang, Han-Peng; Chu, Jie-Mei; Lan, Meng-Dan; Liu, Ping; Yang, Na; Zheng, Fang; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-09-02

    More than 140 modified ribonucleosides have been identified in RNA. Determination of endogenous modified ribonucleosides in biological fluids may serve as non-invasive disease diagnostic strategy. However, detection of the modified ribonucleosides in biological fluids is challenging, especially for the low abundant modified ribonucleosides due to the serious matrix interferences of biological fluids. Here, we developed a facile preparation strategy and successfully synthesized zirconium oxide-silica (ZrO2/SiO2) composite capillary monolithic column that exhibited excellent performance for the selective enrichment of cis-diol-containing compounds. Compared with the boronate-based affinity monolith, the ZrO2/SiO2 monolith showed ∼2 orders of magnitude higher extraction capacity and can be used under physiological pH (pH 6.5-7.5). Using the prepared ZrO2/SiO2 composite monolith as the trapping column and reversed-phase C18 column as the analytical column, we further established an online solid-phase microextraction (SPME) in combination with liquid chromatography-mass spectrometry (online SPME-LC-MS/MS) analysis for the comprehensive profiling of ribonucleosides modification in human urine. Our results showed that 68 cis-diol-containing ribosylated compounds were identified in human urine, which is, to the best of our knowledge, the highest numbers of cis-diol-containing compounds were determined in a single analysis. It is worth noting that four modified ribonucleosides were discovered in the human urine for the first time. In addition, the quantification results from the pooled urine samples showed that compared to healthy controls, the contents of sixteen ribose conjugates in the urine of gastric cancer, eleven in esophagus cancer and seven in lymphoma increased more than two folds. Among these ribose conjugates, four ribose conjugates increased more than two folds in both gastric cancer and esophagus cancer; three ribose conjugates increased more than two

  2. Immobilized fusion protein affinity chromatography combined with HPLC-ESI-Q-TOF-MS/MS for rapid screening of PPARγ ligands from natural products.

    PubMed

    Zhu, Junfeng; Yi, Xiaojiao; Liu, Wenhui; Xu, Yingchun; Chen, Shuqing; Wu, Yongjiang

    2017-04-01

    Screening agonists of peroxisome proliferator-activated receptor-γ (PPARγ) from natural products is particularly motivated by the need for effective anti-diabetic agents. However, method for direct identification of PPARγ ligands from a complex sample is rarely reported. Here we propose a novel immobilized fusion protein affinity chromatography (IFPAC) to achieve rapid multicomponent screening. First, functional human PPARγ ligand binding domain (hPPARγLBD) was bacterially produced by fusion to glutathione S-transferase (GST). The unpurified GST-hPPARγLBD was directly applied to a 96-well filter plate prepacked with glutathione sepharose. Due to the strong affinity between GST and glutathione, the fusion protein could selectively attach to the glutathione matrix with an oriented immobilization, which was rapidly purified under non-denaturing conditions. Experimental results indicated that the prepared 96-affinity column array exhibited excellent selectivity and sensitivity for fishing novel interacting compounds. The proposed approach was applied in the high-throughput screening of PPARγ ligands from natural products, followed by rapid characterization of active compounds using HPLC-ESI-Q-TOF-MS/MS. Isochlorogenic acid A in Dendranthema indicum flowers was found to be a PPARγ ligand. Our findings suggested the IFPAC could be a powerful tool for drug discovery from natural products.

  3. Purification of modified mycobacterial A60 antigen by affinity chromatography and its use for rapid diagnostic tuberculosis infection.

    PubMed

    Yari, Sh; Hadizadeh Tasbiti, A; Fateh, A; Karimi, A; Yari, F; Sakhai, F; Ghazanfari, M; Bahrmand, A

    2011-11-01

    Tuberculosis has been declared a global emergency. The mainstay for its control is the rapid and accurate identification of infected individual. Antibodies to A60, one of the macromolecular antigen complexes of mycobacteria were commonly used in the rapid detection of Mycobacterium tuberculosis. The aim of this study was to prepare specific antibodies against A60 for detection of tuberculosis infection. Specific polyclonal antibodies against A60, (A60-Ab) were prepared in rabbits using 2 boosted injections of the antigen (A60). The antibodies were purified and treated with normal oral flora to remove any non-specific and cross-reactive antibodies. These antibodies were conjugated to CNBr-activated Sepharose 4B and used to isolate subunits of A60 with more specificity for M. tuberculosis. A new affinity column was designed to prepare modified (purified) A60 antigen. Purified A60 antigen (PA60-Ag) was used to develop antibody production by Immunoaffinity chromatography. 113 patients with a confirmed diagnosis of pulmonary TB at Pasteur Institute were selected for the study. The specificity of the results was analyzed with TB-rapid test by using PA60-antibodies. TB-rapid test revealed that normal oral flora-absorbed antibodies could lead to more specific results than that of the non-absorbed antibodies. The developed, modified A60 antibodies, (PA60-Ab)-rapid test showed higher sensitivity, specificity, Positive Predictive Value (PPV), Negative Predictive Value (NPV) and overall efficiency (93.0%, 86.0%, 90.0%, 91.0%, and 90.0% respectively) for the detection of the Mycobacterium antigen. Moreover, PA60-Ag showed only two protein bands of molecular weight 45 and 66kDa in SDS-PAGE while untreated A60 showed multiple bands. Thus, our study helped in the purification of a novel and well characterized A60 antigen and good diagnostic potential for detecting tuberculosis infection.

  4. Characterization of the rabbit homolog of human MUC1 glycoprotein isolated from bladder by affinity chromatography on immobilized jacalin.

    PubMed

    Higuchi, T; Xin, P; Buckley, M S; Erickson, D R; Bhavanandan, V P

    2000-07-01

    The urinary bladder is lined by transitional epithelium, the glycocalyx on the luminal surface has interesting properties and is implicated in protective functions. Glycoconjugates are major components of the glycocalyx, but their biochemical nature is not well understood. Previous studies on rabbit bladder indicated the presence of significant levels of sialoglycoproteins compared to glycosaminoglycans in the epithelium. In this study, rabbit explant cultures were radiolabeled by precursor sugars or amino acids and a major lectin-reactive glycoprotein of rabbit bladder mucosa was isolated by affinity chromatography on jacalin-agarose. The radiolabeled glycoprotein was purified to homogeneity by a second cycle on the lectin column, followed by gel filtration and density gradient centrifugation. The average molecular mass of the glycoprotein was estimated to be 245 kDa and 210 kDa by gel filtration and SDS-PAGE, respectively. Its buoyant density was 1.40 g/ml, suggesting a carbohydrate content of approximately 50%. The percent distribution of glucosamine-derived tritium label in sialic acid, galactosamine, and glucosamine was 30, 52, and 18, respectively. The glycoprotein consisted entirely of small sialylated and neutral oligosaccharides O-glycosidically linked to serine and threonine residues. The same glycoprotein could be immunoprecipitated with an antibody against the carboxy terminal 17 amino acid peptide of human MUC1 mucin glycoprotein. This suggests that this mucin glycoprotein is the rabbit homolog of MUC1 glycoprotein, which has been previously established to be a component of human bladder urothelium and has been purified from human urine and biochemically characterized.

  5. Purification and characterization of two types of Cytisus sessilifolius anti-H(O) lectins by affinity chromatography.

    PubMed

    Konami, Y; Yamamoto, K; Osawa, T

    1991-02-01

    Two anti-H(O) lectins were separated from extracts of Cytisus sessilifolius seeds by successive affinity chromatographies on columns of di-N-acetylchitobiose- and galactose-Sepharose 4B. One was found to be inhibited most by di-N-acetylchitotriose or tri-N-acetylchitotriose [Cytisus-type anti-H(O) lectin designated as Cytisus sessilifolius lectin I (CSA-I)] and the other anti-H(O) lectin was inhibited by galactose or lactose and designated as Cytisus sessilifolius lectin II (CSA-II). These two anti-H(O) lectins were further purified by gel filtration on TSK-Gel G3000SW. These preparations were homogeneous as judged by polyacrylamide gel electrophoresis and gel filtration. The molecular masses of the purified lectins I and II were found to be 95,000 and 68,000 Da, respectively, by gel filtration on TSK-Gel G3000SW. On polyacrylamide gel electrophoresis in the presence of sodium dodecyl sulfate and 2-mercaptoethanol, both lectins gave a single component of molecular masses of 27,000 +/- 2,000 and 34,000 +/- 2,000 Da, respectively, suggesting that the lectins I and II were composed of four and two apparently identical subunits, respectively. Lectins I and II contain 38% and 13% carbohydrate, respectively, and only very small amounts of cysteine and methionine, but they are rich in aspartic acid, serine and glycine. The N-terminal amino-acid sequences of these two lectins were determined and compared with those of several lectins already published.

  6. On-column micro gas chromatography detection with capillary-based optical ring resonators.

    PubMed

    Shopova, Siyka I; White, Ian M; Sun, Yuze; Zhu, Hongying; Fan, Xudong; Frye-Mason, Greg; Thompson, Aaron; Ja, Shiou-jyh

    2008-03-15

    We developed a novel on-column micro gas chromatography (microGC) detector using capillary based optical ring resonators (CBORRs). The CBORR is a thin-walled fused silica capillary with an inner diameter ranging from a few tens to a few hundreds of micrometers. The interior surface of the CBORR is coated with a layer of stationary phase for gas separation. The circular cross section of the CBORR forms a ring resonator and supports whispering gallery modes (WGMs) that circulate along the ring resonator circumference hundreds of times. The evanescent field extends into the core and is sensitive to the refractive index change induced by the interaction between the gas sample and the stationary phase. The WGM can be excited and monitored at any location along the CBORR by placing a tapered optical fiber against the CBORR, thus enabling on-column real-time detection. Rapid separation of both polar and nonpolar samples was demonstrated with subsecond detection speed. Theoretical work was also established to explain the CBORR detection mechanism. While low-nanogram detection limits are observed in these preliminary tests, many methods for improvements are under investigation. The CBORR is directly compatible with traditional capillary GC columns without any dead volumes. Therefore, the CBORR-based muGC is a very promising technology platform for rapid, sensitive, and portable analytical devices.

  7. Direct coupling of packed column supercritical fluid chromatography to continuous corona discharge ion mobility spectrometry.

    PubMed

    Rahmanian, A; Ghaziaskar, H S; Khayamian, T

    2013-01-11

    In this study, packed column supercritical fluid chromatography (SFC) was directly coupled to a continuous corona discharge (CD) ion mobility spectrometer (IMS) with several modifications. The main advantage of the developed detector is its capability to introduce full column effluent up to 2000 mL min(-1) CO(2) gas directly into the IMS cell relative to 40 mL min(-1) CO(2) gas as a maximum tolerance, reported for the previous IMS detectors. This achievement was made possible because of using corona discharge instead of (63)Ni as an ionization source and locating the inlet and outlet of the CO(2) gas in the counter electrode of the CD in opposite direction. In addition, a heated interface was placed between back pressure regulator (BPR) and the IMS cell to heat the output of the BPR for introducing sample as the gas phase into the IMS cell. Furthermore, a make-up methanol flow was introduced between the column outlet and BPR to provide a more uniform flow through the BPR and also to prevent freezing and deposition of the analytes in the BPR. The performance of the SFC-CD-IMS was evaluated by analysis of testosterone, medroxyprogesterone, caffeine, and theophylline as test compounds and figures of merit for these compounds have been calculated.

  8. Separation of tissue and serum acid phosphatase isoenzymes by ion-exchange column chromatography.

    PubMed

    Mercer, D W

    1977-01-01

    I describe a simple, rapid ion-exchange column-chromatographic technique for separating the acid phosphatase (EC 3.1.3.2) isoenzymes in human serum and tissue. Extracts of platelets, spleen, liver, erythrocytes, and prostate were used to determine optimum conditions for separating these isoenzymes. Samples layered on mini-colunms of DEAE-Sephadex A-50 were eluted stepwise with sodium chloride (100, 200, and 300 mmol/liter, buffered with tris (hydroxymethyl)aminomethane). Activity in column effluents was measured with p-nitrophenol phosphate as substrate, and their isoenzyme content was assessed by electrophoresis on polyacrylamide gel. Comparision of activity patterns so derived for various tissues revealed prostatic tissue to be a rich source of acid phosphatase isoenzyme 2 activity. Evaluation of sera from six patients with prostatic cancer revealed isoenzyme patterns with prominent amount of isoenzyme 2 (3.8 to 27.6 U/liter). sera from 10 healthy laboratory technicians contained isoenzyme 2 in the range of 0.3-0.5 U/liter. Samples from two patients with abnormally high activity owing to nonprostatic conditions (Gaucher's disease and carcinoma of lung) exhibited less than 2 U of isoenzyme 2 per liter and acid phosphatase isoenzymes 3-5 that were 50- to 100-fold the normal range. Quantification of isoenzyme 2 by DEAE-Sephadex column chromatography as described appears to provide a more sensitive and specific approach to diagnosis of prostatic cancer.

  9. Analysis of fifteen estrogen metabolites using packed column supercritical fluid chromatography-mass spectrometry.

    PubMed

    Xu, Xia; Roman, John M; Veenstra, Timothy D; Van Anda, Jennifer; Ziegler, Regina G; Issaq, Haleem J

    2006-03-01

    Packed column supercritical fluid chromatography with tandem mass spectrometry was used for the separation of estrone, estradiol, estriol, 16-epiestriol, 17-epiestriol, 16-ketoestradiol, 16alpha-hydroxyestrone, 2-methoxyestrone, 4-methoxyestrone, 2-hydroxyestrone-3-methyl ether, 2-methoxyestradiol, 4-methoxyestradiol, 2-hydroxyestrone, 4-hydroxyestrone, and 2-hydroxyestradiol. A gradient of methanol in carbon dioxide (0-30% methanol in 15 min, 2% change/min) at a flow rate of 2 mL/min and cyanopropyl silica column connected in series with a diol column, both 2.1 mm i.d. x 150 mm long, packed with 5-mum spherical silica-based particles, resulted in the separation and quantification of all 15 estrogens in less than 10 min. The limit of detection (LOD) and limit of quantitation (LOQ) of this pSFC MS/MS method was determined to be 0.5 (S/N = 3), and 5 pg, respectively. Compared with RP-HPLC MS analysis of the same mixture in terms of speed of analysis and sensitivity, pSFC MS is much faster, 10 versus 70 min, with comparable LOD and LOQ.

  10. Penetrable silica microspheres for immobilization of bovine serum albumin and their application to the study of the interaction between imatinib mesylate and protein by frontal affinity chromatography.

    PubMed

    Ma, Liyun; Li, Jing; Zhao, Juan; Liao, Han; Xu, Li; Shi, Zhi-guo

    2016-01-01

    In the current study, novel featured silica, named penetrable silica, simultaneously containing macropores and mesopores, was immobilized with bovine serum albumin (BSA) via Schiff base method. The obtained BSA-SiO2 was employed as the high-performance liquid chromatographic (HPLC) stationary phase. Firstly, D- and L-tryptophan were used as probes to investigate the chiral separation ability of the BSA-SiO2 stationary phase. An excellent enantioseparation factor was obtained up to 4.3 with acceptable stability within at least 1 month. Next, the BSA-SiO2 stationary phase was applied to study the interaction between imatinib mesylate (IM) and BSA by frontal affinity chromatography. A single type of binding site was found for IM with the immobilized BSA, and the hydrogen-bonding and van der Waals interactions were expected to be contributing interactions based on the thermodynamic studies, and this was a spontaneous process. Compared to the traditional silica for HPLC stationary phase, the proposed penetrable silica microsphere possessed a larger capacity to bond more BSA, minimizing column overloading effects and enhancing enantioseparation ability. In addition, the lower running column back pressure and fast mass transfer were meaningful for the column stability and lifetime. It was a good substrate to immobilize biomolecules for fast chiral resolution and screening drug-protein interactions.

  11. Evaluation of steric exclusion chromatography on cryogel column for the separation of serum proteins.

    PubMed

    Wang, Chuan; Bai, Shu; Tao, Shi-Peng; Sun, Yan

    2014-03-14

    Steric exclusion chromatography (SXC) is a new mode of protein chromatography, in which large proteins are retained on hydrophilic stationary phase surface due to the steric exclusion of polyethylene glycol (PEG) in the mobile phase, and thereafter the retained proteins can be eluted by reducing PEG concentration. In this work, SXC was evaluated on a polyacrylamide cryogel monolith. Microscopic observation of γ-globulin precipitates on the gel surface in SXC was reported for the first time. Due to the compact packing of protein precipitates on the stationary phase surface, the dynamic retention capacity of the cryogel monolith for γ-globulin reached 20 mg/mL bed volume, much higher than those of cryogel beds in adsorption-based chromatography. The effect of molecular weight and concentration of PEG, solution pH and salt concentration on protein retention capacity was in agreement with the earlier work on SXC. Because the cryogel monoliths with interconnected macropores (10-100 μm) allow much easy flow-through of viscous PEG buffer, the SXC can be operated at low back pressure. Hence, the cryogel monoliths are more suitable for SXC than other monoliths of narrow pores reported previously. In the separation of bovine serum proteins, albumin was recovered in the breakthrough fraction with high purity, and globulin was over eight times concentrated in the elution pool. This work has, thus, demonstrated the rapid serum protein separation and concentration by SXC on the cryogel monolith columns.

  12. Recombinant Passenger Proteins Can Be Conveniently Purified by One-Step Affinity Chromatography.

    PubMed

    Wang, Hua-zhen; Chu, Zhi-zhan; Chen, Chang-chao; Cao, Ao-cheng; Tong, Xin; Ouyang, Can-bin; Yuan, Qi-hang; Wang, Mi-nan; Wu, Zhong-kun; Wang, Hai-hong; Wang, Sheng-bin

    2015-01-01

    Fusion tag is one of the best available tools to date for enhancement of the solubility or improvement of the expression level of recombinant proteins in Escherichia coli. Typically, two consecutive affinity purification steps are often necessitated for the purification of passenger proteins. As a fusion tag, acyl carrier protein (ACP) could greatly increase the soluble expression level of Glucokinase (GlcK), α-Amylase (Amy) and GFP. When fusion protein ACP-G2-GlcK-Histag and ACP-G2-Amy-Histag, in which a protease TEV recognition site was inserted between the fusion tag and passenger protein, were coexpressed with protease TEV respectively in E. coli, the efficient intracellular processing of fusion proteins was achieved. The resulting passenger protein GlcK-Histag and Amy-Histag accumulated predominantly in a soluble form, and could be conveniently purified by one-step Ni-chelating chromatography. However, the fusion protein ACP-GFP-Histag was processed incompletely by the protease TEV coexpressed in vivo, and a large portion of the resulting target protein GFP-Histag aggregated in insoluble form, indicating that the intracellular processing may affect the solubility of cleaved passenger protein. In this context, the soluble fusion protein ACP-GFP-Histag, contained in the supernatant of E. coli cell lysate, was directly subjected to cleavage in vitro by mixing it with the clarified cell lysate of E. coli overexpressing protease TEV. Consequently, the resulting target protein GFP-Histag could accumulate predominantly in a soluble form, and be purified conveniently by one-step Ni-chelating chromatography. The approaches presented here greatly simplify the purification process of passenger proteins, and eliminate the use of large amounts of pure site-specific proteases.

  13. Virus elimination during the purification of monoclonal antibodies by column chromatography and additional steps.

    PubMed

    Roberts, Peter L

    2014-01-01

    The theoretical potential for virus transmission by monoclonal antibody based therapeutic products has led to the inclusion of appropriate virus reduction steps. In this study, virus elimination by the chromatographic steps used during the purification process for two (IgG-1 & -3) monoclonal antibodies (MAbs) have been investigated. Both the Protein G (>7log) and ion-exchange (5 log) chromatography steps were very effective for eliminating both enveloped and non-enveloped viruses over the life-time of the chromatographic gel. However, the contribution made by the final gel filtration step was more limited, i.e., 3 log. Because these chromatographic columns were recycled between uses, the effectiveness of the column sanitization procedures (guanidinium chloride for protein G or NaOH for ion-exchange) were tested. By evaluating standard column runs immediately after each virus spiked run, it was possible to directly confirm that there was no cross contamination with virus between column runs (guanidinium chloride or NaOH). To further ensure the virus safety of the product, two specific virus elimination steps have also been included in the process. A solvent/detergent step based on 1% triton X-100 rapidly inactivating a range of enveloped viruses by >6 log inactivation within 1 min of a 60 min treatment time. Virus removal by virus filtration step was also confirmed to be effective for those viruses of about 50 nm or greater. In conclusion, the combination of these multiple steps ensures a high margin of virus safety for this purification process.

  14. High performance affinity chromatography (HPAC) as a high-throughput screening tool in drug discovery to study drug-plasma protein interactions.

    PubMed

    Vuignier, Karine; Guillarme, Davy; Veuthey, Jean-Luc; Carrupt, Pierre-Alain; Schappler, Julie

    2013-02-23

    Drug-plasma protein binding is an important parameter that, together with other physicochemical properties such as lipophilicity and pK(a), greatly influences drug absorption, distribution, metabolism, and excretion (ADME). Therefore, it is important for pharmaceutical companies to develop a rapid screening assay to examine plasma protein binding during the early stages of the drug discovery process. Human serum albumin (HSA) and α(1)-acid glycoprotein (AGP) are the most important plasma proteins that are capable of binding drugs. In this work, an automated and high-throughput (<3 min/compound) strategy was developed using high performance affinity chromatography (HPAC) with commercial HSA and AGP columns to evaluate drug-plasma protein interactions for drug screening. A generic gradient was used throughout the study to separate drugs that were weakly and tightly bound to HSA and AGP. To accelerate the analysis time, the system was calibrated in a single run by pooling reference compounds without overloading the column. For both HSA and AGP studies, the developed methods were successfully transferred from HPAC-UV to HPAC-MS with single quadrupole MS detection and ammonium acetate, pH 7.0 as a volatile mobile phase. The MS detection enhanced the sensitivity, selectivity, and throughput of the method by pooling unknown compounds. For HSA analyses, the binding percentages obtained using HPAC were well correlated with the binding percentages from the literature. This method was also able to rank compounds based on their affinity for HSA. Concerning the AGP analyses, the quality of the correlation between the binding percentages obtained in HPAC and those from the literature was weaker. However, the method was able to classify compounds into weak, medium, and strong binders and rank compounds based on their affinity for AGP.

  15. [Online enrichment ability of restricted-access column coupled with high performance liquid chromatography by column switching technique for benazepril hydrochloride].

    PubMed

    Zhang, Xiaohui; Wang, Rong; Xie, Hua; Yin, Qiang; Li, Xiaoyun; Jia, Zhengping; Wu, Xiaoyu; Zhang, Juanhong; Li, Wenbin

    2013-05-01

    The online enrichment ability of the restricted-access media (RAM) column coupled with high performance liquid chromatography by column switching technique for benazepril hydrochloride in plasma was studied. The RAM-HPLC system consisted of an RAM column as enrichment column and a C18 column as analytical column coupled via the column switching technique. The effects of the injection volume on the peak area and the systematic pressure were studied. When the injection volume was less than 100 microL, the peak area increased with the increase of the injection volume. However, when the injection volume was more than 80 microL, the pressure of whole system increased obviously. In order to protect the whole system, 80 microL was chosen as the maximum injection volume. The peak areas of ordinary injection and the large volume injection showed a good linear relationship. The enrichment ability of RAM-HPLC system was satisfactory. The system was successfully used for the separation and detection of the trace benazepril hydrochloride in rat plasma after its administration. The sensitivity of HPLC can be improved by RAM pre-enrichment. It is a simple and economic measurement method.

  16. Rapid tandem-column micro-gas chromatography based on optofluidic ring resonators with multi-point on-column detection.

    PubMed

    Sun, Yuze; Liu, Jing; Howard, Daniel J; Frye-Mason, Greg; Thompson, Aaron K; Ja, Shiou-jyh; Fan, Xudong

    2010-01-01

    We demonstrated a novel tandem-column micro-gas chromatography (microGC) based on optofluidic ring resonator (OFRR). The OFRR is a thin-walled fused silica capillary whose interior surface is coated with a polymeric stationary phase. The circular cross section of the OFRR forms the micro-ring resonator and supports whispering gallery modes (WGMs). Via tapered optical fibers in contact with the OFRR, the WGM can be excited externally at any positions along the OFRR capillary, thus enabling multi-point, on-column, real-time detection of vapor molecules flowing through the OFRR. In the present OFRR-based tandem-column-based microGC implementation, a 180 cm long conventional GC column coated with a nonpolar stationary phase was followed by a relatively short OFRR column coated with a polar phase. Two detection positions, one at the inlet of the OFRR and the other a few centimeters downstream, were used to monitor the separation achieved by the first and the second column, respectively. Owing to the multi-point on-column detection that provides complementary retention time information on each chemical compound, co-eluted analytes can be well separated and identified on at least one detection channel and no modulation is needed at the interface of tandem columns. Separation and detection of twelve analytes with various volatilities and polarities within four minutes were demonstrated. In addition, the chromatograms obtained from three different locations along the OFRR column demonstrated the system's capability of on-column monitoring of the separation process for the target analyte in a vapor mixture. Our results will lead to the development of a rapid, simple, and portable microGC system with significantly improved selectivity and chemical identification capabilities.

  17. Dynamic affinity chromatography in the separation of sulfated lignins binding to thrombin

    PubMed Central

    Liang, Aiye; Thakkar, Jay N.; Hindle, Michael; Desai, Umesh R.

    2013-01-01

    Sulfated low molecular weight lignins (LMWLs), a mixture of chemo-enzymatically prepared oligomers, have been found to be potent antagonists of coagulation. However, structures that induce anticoagulation remain unidentified. The highly polar sulfate groups on these molecules and the thousands of different structures present in these mixtures make traditional chromatographic resolution of sulfated LMWLs difficult. We performed dynamic thrombin affinity chromatography monitored using chromogenic substrate hydrolysis assay to isolate sulfated LMWL fractions that differed significantly in their biophysical and biochemical properties. Three fractions, I35, I55 and Peak II, were isolated from the starting complex mixture. Independent plasma clotting assays suggested that I35 possessed good anticoagulation potential (APTT = 4.2 μM; PT = 6.8 μM), while I55 and Peak II were approximately 10- and 100-fold less potent. The ESI-MS spectrum of this oligomeric fraction showed multiple peaks at 684.8, 610.6, 557.4, 541.4, 536.5, and 519.4 m/z, which most probably arise from variably functionalized (β-O4—β-β-linked trimers and/or a β-O4—β-O4-linked dimers. The first direct observation of these structures in sulfated LMWLs will greatly assist in the discovery of more potent sulfated LMWL-based anticoagulants. PMID:23122400

  18. NMR screening of new carbocyanine dyes as ligands for affinity chromatography.

    PubMed

    Cruz, Carla; Boto, Renato E F; Drzazga, Anna K; Almeida, Paulo; Queiroz, João A

    2014-04-01

    Four new carbocyanines containing symmetric and asymmetric heterocyclic moieties and N-carboxyalkyl groups have been synthesized and characterized. The binding mechanism established between these cyanines and several proteins was evaluated using saturation transfer difference (STD) NMR. The results obtained for the different dyes revealed a specific interaction to the standard proteins lysozyme, α-chymotrypsin, ribonuclease (RNase), bovine serum albumin (BSA), and gamma globulin. For instance, the two un-substituted symmetrical dyes (cyanines 1 and 3) interacted preferentially through its benzopyrrole and dibenzopyrrole units with lysozyme, α-chymotrypsin, and RNase, whereas the symmetric disulfocyanine dye (cyanine 2) bound BSA and gamma globulin through its carboxyalkyl chains. On the other hand, the asymmetric dye (cyanine 4) interacts with lysozyme and α-chymotrypsin through benzothiazole moiety and with RNase through dibenzopyrrole unit. Thus, STD-NMR technique was successfully used to screen cyanine-protein interactions and determine potential binding sites of the cyanines for posterior use as ligands in affinity chromatography.

  19. Purification of human immunoglobulin G autoantibodies to tumor necrosis factor using affinity chromatography and magnetic separation.

    PubMed

    Sennikov, S V; Golikova, E A; Kireev, F D; Lopatnikova, J A

    2013-04-30

    Autoantibodies to cytokines are important biological effector molecules that can regulate cytokine activities. The aim of the study was to develop a protocol to purify autoantibodies to tumor necrosis factor from human serum, for use as a calibration material to determine the absolute content of autoantibodies to tumor necrosis factor by enzyme-linked immunosorbent assay. The proposed protocol includes a set of affinity chromatography methods, namely, Bio-Gel P6DG sorbent to remove albumin from serum, Protein G Sepharose 4 Fast Flow to obtain a total immunoglobulin G fraction of serum immunoglobulins, and Affi-Gel 15 to obtain specifically antibodies to tumor necrosis factor. The addition of a magnetic separation procedure to the protocol eliminated contaminant tumor necrosis factor from the fraction of autoantibodies to tumor necrosis factor. The protocol generated a pure fraction of autoantibodies to tumor necrosis factor, and enabled us to determine the absolute concentrations of different subclasses of immunoglobulin G autoantibodies to tumor necrosis factor in apparently healthy donors.

  20. Purification of a thermostable alkaline laccase from papaya (Carica papaya) using affinity chromatography.

    PubMed

    Jaiswal, Nivedita; Pandey, Veda P; Dwivedi, Upendra N

    2015-01-01

    A laccase from papaya leaves was purified to homogeneity by a two step procedure namely, heat treatment (at 70 °C) and Con-A affinity chromatography. The procedure resulted in 1386.7-fold purification of laccase with a specific activity of 41.3 units mg(-1) and an overall yield of 61.5%. The native purified laccase was found to be a hexameric protein of ∼ 260 kDa. The purified enzyme exhibited acidic and alkaline pH optima of 6.0 and 8.0 with the non-phenolic substrate (ABTS) and phenolic substrate (catechol), respectively. The purified laccase was found to be thermostable up to 70 °C such that it retained ∼ 80% activity upon 30 min incubation at 70 °C. The Arrhenius energy of activation for purified laccase was found to be 7.7 kJ mol(-1). The enzyme oxidized various phenolic and non-phenolic substrates having catalytic efficiency (K(cat)/K(m)) in the order of 7.25>0.67>0.27 mM(-1) min(-1) for ABTS, catechol and hydroquinone, respectively. The purified laccase was found to be activated by Mn(2+), Cd(2+), Ca(2+), Na(+), Fe(2+), Co(2+) and Cu(2+) while weakly inhibited by Hg(2+). The properties such as thermostability, alkaline pH optima and metal tolerance exhibited by the papaya laccase make it a promising candidate enzyme for industrial exploitation.

  1. Intrinsic advantages of packed capillaries over narrow-bore columns in very high-pressure gradient liquid chromatography.

    PubMed

    Gritti, Fabrice; McDonald, Thomas; Gilar, Martin

    2016-06-17

    250μm×100mm fused silica glass capillaries were packed with 1.8μm high-strength silica (HSS) fully porous particles. They were prepared without bulky stainless steel endfittings and metal frits, which both generate significant sample dispersion. The isocratic efficiencies and gradient peak capacities of these prototype capillary columns were measured for small molecules (n-alkanophenones) using a home-made ultra-low dispersive micro-HPLC instrument. Their resolution power was compared to that of standard 2.1mm×100mm very high-pressure liquid chromatography (vHPLC) narrow-bore columns packed with the same particles. The results show that, for the same column efficiency (25000 plates) and gradient steepness (0.04min(-1)), the peak capacity of the 250μm i.d. capillary columns is systematically 15-20% higher than that of the 2.1mm i.d. narrow-bore columns. A validated model of gradient chromatography enabled one to predict accurately the observed peak capacities of the capillary columns for non-linear solvation strength retention behavior and under isothermal conditions. Thermodynamics applied to the eluent quantified the temperature difference for the thermal gradients in both capillary and narrow-bore columns. Experimental data revealed that the gradient peak capacity is more affected by viscous heating than the column efficiency. Unlike across 2.1mm i.d. columns, the changes in eluent composition across the 250μm i.d. columns during the gradient is rapidly relaxed by transverse dispersion. The combination of (1) the absence of viscous heating and (2) the high uniformity of the eluent composition across the diameter of capillary columns explains the intrinsic advantage of capillary over narrow-bore columns in gradient vHPLC.

  2. Temperature-assisted On-column Solute Focusing: A General Method to Reduce Pre-column Dispersion in Capillary High Performance Liquid Chromatography

    PubMed Central

    Groskreutz, Stephen R.; Weber, Stephen G.

    2014-01-01

    Solvent-based on-column focusing is a powerful and well known approach for reducingthe impact of pre-column dispersion in liquid chromatography. Here we describe an orthogonal temperature-based approach to focusing called temperature-assisted on-column solute focusing (TASF). TASF is founded on the same principles as the more commonly used solvent-based method wherein transient conditions are created thatlead to high solute retention at the column inlet. Combining the low thermal mass of capillary columns and the temperature dependence of solute retentionTASF is used effectivelyto compress injection bands at the head of the column through the transient reduction in column temperature to 5 °C for a defined 7 mm segment of a 6 cm long 150 μm I.D. column. Following the 30 second focusing time, the column temperature is increased rapidly to the separation temperature of 60 °C releasing the focused band of analytes. We developed a model tosimulate TASF separations based on solute retention enthalpies, focusing temperature, focusing time, and column parameters. This model guides the systematic study of the influence of sample injection volume on column performance.All samples have solvent compositions matching the mobile phase. Over the 45 to 1050 nL injection volume range evaluated, TASF reducesthe peak width for all soluteswith k’ greater than or equal to 2.5, relative to controls. Peak widths resulting from injection volumes up to 1.3 times the column fluid volume with TASF are less than 5% larger than peak widths from a 45 nL injection without TASF (0.07 times the column liquid volume). The TASF approach reduced concentration detection limits by a factor of 12.5 relative to a small volume injection for low concentration samples. TASF is orthogonal to the solvent focusing method. Thus, it canbe used where on-column focusing is required, but where implementation of solvent-based focusing is difficult. PMID:24973805

  3. Temperature-assisted on-column solute focusing: a general method to reduce pre-column dispersion in capillary high performance liquid chromatography.

    PubMed

    Groskreutz, Stephen R; Weber, Stephen G

    2014-08-08

    Solvent-based on-column focusing is a powerful and well known approach for reducing the impact of pre-column dispersion in liquid chromatography. Here we describe an orthogonal temperature-based approach to focusing called temperature-assisted on-column solute focusing (TASF). TASF is founded on the same principles as the more commonly used solvent-based method wherein transient conditions are created that lead to high solute retention at the column inlet. Combining the low thermal mass of capillary columns and the temperature dependence of solute retention TASF is used effectively to compress injection bands at the head of the column through the transient reduction in column temperature to 5°C for a defined 7mm segment of a 6cm long 150μm I.D. column. Following the 30s focusing time, the column temperature is increased rapidly to the separation temperature of 60°C releasing the focused band of analytes. We developed a model to simulate TASF separations based on solute retention enthalpies, focusing temperature, focusing time, and column parameters. This model guides the systematic study of the influence of sample injection volume on column performance. All samples have solvent compositions matching the mobile phase. Over the 45-1050nL injection volume range evaluated, TASF reduces the peak width for all solutes with k' greater than or equal to 2.5, relative to controls. Peak widths resulting from injection volumes up to 1.3 times the column fluid volume with TASF are less than 5% larger than peak widths from a 45nL injection without TASF (0.07 times the column liquid volume). The TASF approach reduced concentration detection limits by a factor of 12.5 relative to a small volume injection for low concentration samples. TASF is orthogonal to the solvent focusing method. Thus, it can be used where on-column focusing is required, but where implementation of solvent-based focusing is difficult.

  4. Separation of Be and Al for AMS using single-step column chromatography

    NASA Astrophysics Data System (ADS)

    Binnie, Steven A.; Dunai, Tibor J.; Voronina, Elena; Goral, Tomasz; Heinze, Stefan; Dewald, Alfred

    2015-10-01

    With the aim of simplifying AMS target preparation procedures for TCN measurements we tested a new extraction chromatography approach which couples an anion exchange resin (WBEC) to a chelating resin (Beryllium resin) to separate Be and Al from dissolved quartz samples. Results show that WBEC-Beryllium resin stacks can be used to provide high purity Be and Al separations using a combination of hydrochloric/oxalic and nitric acid elutions. 10Be and 26Al concentrations from quartz samples prepared using more standard procedures are compared with results from replicate samples prepared using the coupled WBEC-Beryllium resin approach and show good agreement. The new column procedure is performed in a single step, reducing sample preparation times relative to more traditional methods of TCN target production.

  5. Residual on column host cell protein analysis during lifetime studies of protein A chromatography.

    PubMed

    Lintern, Katherine; Pathak, Mili; Smales, C Mark; Howland, Kevin; Rathore, Anurag; Bracewell, Daniel G

    2016-08-26

    Capacity reduction in protein A affinity chromatography with extended cycling during therapeutic antibody manufacture is well documented. Identification of which residual proteins remain from previous cycles during the lifetime of these adsorbent materials is required to understand their role in this ageing process, but represents a significant metrological challenge. Scanning electron microscopy (SEM) and liquid chromatography mass spectrometry (LC-MS/MS) are combined to detect and map this phenomenon of protein carry-over. We show that there is a morphological change at the surface of the agarose resin, revealing deposits on the polymer fibres increasing with cycle number. The amount of residual host cell proteins (HCPs) by LC-MS/MS present on the resin is shown to increase 10-fold between 50 and 100 cycles. During this same period the functional class of the predominant HCPs associated with the resin increased in diversity, with number of proteins identified increasing 5-fold. This ageing is observed in the context of the product quality of the eluate HCP and protein A leachate concentration remaining constant with cycle number.

  6. Effect of pre- and post-column band broadening on the performance of high-speed chromatography columns under isocratic and gradient conditions.

    PubMed

    Vanderlinden, Kim; Broeckhoven, Ken; Vanderheyden, Yoachim; Desmet, Gert

    2016-04-15

    We report on the results of an experimental and theoretical study of the effect of the extra-column band broadening (ECBB) on the performance of narrow-bore columns filled with the smallest particles that are currently commercially available. Emphasis is on the difference between the effect of ECBB under gradient and isocratic conditions, as well as on the ability to model and predict the ECBB effects using well-established band broadening expressions available from the theory of chromatography. The fine details and assumptions that need to be taken into account when using these expressions are discussed. The experiments showed that, the steeper the gradient, the more pronounced the extra-column band broadening losses become. Whereas the pre-column band broadening can in both isocratic and gradient elution be avoided by playing on the possibilities to focus the analytes on top of the column (e.g. by using the POISe injection method when running isocratic separations), the post-column extra-column band broadening is inescapable in both cases. Inducing extra-column band broadening by changing the inner diameter of the post-column tubing from 65 to 250 μm, we found that all peaks in the chromatogram are strongly affected (around a factor of 1.9 increase in relative peak width) when running steep gradients, while usually only the first eluting peak was affected in the isocratic mode or when running shallow gradients (factor 1.6-1.8 increase in relative peak width for the first eluting analyte).

  7. Increased Yield of High Purity Recombinant Human Interferon-γ Utilizing Reversed Phase Column Chromatography

    PubMed Central

    Reddy, Praveen K.; Reddy, Srinivasa G.; Narala, Venkata R.; Majee, Sangita S.; Konda, Sudhakar; Gunwar, Sripad; Reddy, Raju C.

    2007-01-01

    Increasing therapeutic applications for recombinant human interferon-γ (rhIFN-γ), an antiviral proinflammatory cytokine, has broadened interest in optimizing methods for its production and purification. We describe a reversed phase chromatography (RPC) procedure using Source-30™ matrix in the purification of rhIFN-γ from Escherichia coli that results in a higher yield than previously reported. The purified rhIFN-γ monomer from the RPC column is refolded in Tris buffer. Optimal refolding occurs at protein concentrations between 50–100 μg/ml. This method yields greater than 90% of the dimer form with a yield of 40 mg g−1 cell mass. Greater than 99% purity is achieved with further purification over a Superdex G-75 column to obtain specific activities of from 2 to 4 × 107 IU/mg protein as determined via cytopathic antiviral assay. The improved yield of rhIFN-γ in a simple chromatographic purification procedure promises to enhance the development and therapeutic application of this biologically potent molecule. PMID:17049266

  8. Chromatographic performance of large-pore versus small-pore columns in micellar liquid chromatography.

    PubMed

    McCormick, Timothy J; Foley, Joe P; Lloyd, David K

    2003-02-25

    Micellar liquid chromatography (MLC) is useful in bioanalysis because proteinaceous biofluids can be directly injected onto the column. The technique has been limited in part because of the apparently weak eluting power of micellar mobile phases. It has recently been shown [Anal. Chem. 72 (2000) 294] that this may be overcome by the use of large pore size stationary phases. In this work, large-pore (1000 A) C(18) stationary phases were evaluated relative to conventional small-pore (100 A) C(18) stationary phases for the direct sample injection of drugs in plasma. Furthermore, the difference between the large and small pore phases in gradient elution separations of mixtures of widely varying hydrophobicities was investigated. Large-pore stationary phases were found to be very effective for eluting moderately to highly hydrophobic compounds such as ibuprofen, crotamiton, propranolol, and dodecanophenone, which were highly retained on the small-pore stationary phases typically used in MLC. The advantages of direct introduction of biological samples (drugs in plasma) and rapid column re-equilibration after gradient elution in MLC were maintained with large-pore phases. Finally, recoveries, precision, linearity, and detection limits for the determination of quinidine and DPC 961 in spiked bovine plasma were somewhat better using MLC with wide pore phases.

  9. Resolution of diacylglycerol moieties of natural glycerophospholipids by gas-liquid chromatography on polar capillary columns.

    PubMed

    Myher, J J; Kuksis, A

    1982-06-01

    A rapid and practical method has been developed for the gas-liquid chromatographic determination of the sn-1,2-diacylglycerol moieties of natural glycerophospholipids using polar wall-coated open tubular columns. The method gives complete resolution and quantitative estimates for all species according to molecular weight and degree of unsaturation, including stearoyl docosahexaenoylglycerol and related polyunsaturates. For this purpose the sn-1,2-diacylglycerols are obtained from the glycerophospholipids by hydrolysis with phospholipase C and are converted into the trimethylsilyl or tertiary-butyldimethylsilyl ethers. The silyl ethers are separated by gas-liquid chromatography on the capillary glass columns coated with a polar cyanopropylsiloxane polymer, in the temperature range 175-250 degrees C, using hydrogen as the carrier gas. Practical applications of the method are illustrated by analyses of the sn-1,2-diacylglycerol moieties of the phosphatidylcholines of soybean phosphatides, egg yolk, and rat liver. The method of analysis is applicable to other classes of glycerophospholipids and the total time requirements for the analysis of any one phospholipid class are comparable to those for a fatty acid analysis.

  10. Understanding and diminishing the extra-column band broadening effects in supercritical fluid chromatography.

    PubMed

    De Pauw, Ruben; Shoykhet Choikhet, Konstantin; Desmet, Gert; Broeckhoven, Ken

    2015-07-17

    Supercritical fluid chromatography, where a low-viscosity mobile phase such as carbon dioxide is used, proves to be an excellent technique for fast and efficient separations, especially when sub-2μm particles are used. However, to achieve high velocities when using these small particles, and in order to stay within the flow rate range of current SFC-instruments, narrow columns (e.g. 2.1mm ID) must be used. Unfortunately, state-of-the-art instrumentation is limiting the full separation power of these narrower columns due to significant extra-column band broadening effects. The present work identifies and quantifies the different contributions to extra-column band broadening in SFC such as the influence of the sample solvent, injection volume, extra-column volumes and detector cell volume/design. When matching the sample solvent to the mobile phase in terms of elution strength and polarity (e.g. using hexane/ethanol/isopropanol 85/10/5vol%) and lowering the injection volume to 0.4μL, the plate count can be increased from 7600 to 21,300 for a low-retaining compound (k'=2.3) on a 2.1mm×150mm column (packed with 1.8μm particles). The application of a water/acetonitrile mixture as sample solvent was also investigated. It was found that when the volumetric ratio of water/acetonitrile was optimized, only a slightly lower plate count was measured compared to the hexane-based solvent when minimizing injection and extra-column volume. This confirms earlier results that water/acetonitrile can be used if water-soluble samples are considered or when a less volatile solvent is preferred. Minimizing the ID of the connection capillaries from 250 to 65μm, however, gives no further improvement in obtained efficiency for early-eluting compounds when a standard system configuration with optimized sample solvent was used. When switching to a state-of-the-art detector design with reduced (dispersion) volume (1.7-0.6μL), an increase in plate count is observed (from 11,000 to 14

  11. Selection of column dimensions and gradient conditions to maximize the peak-production rate in comprehensive off-line two-dimensional liquid chromatography using monolithic columns.

    PubMed

    Eeltink, Sebastiaan; Dolman, Sebastiaan; Vivo-Truyols, Gabriel; Schoenmakers, Peter; Swart, Remco; Ursem, Mario; Desmet, Gert

    2010-08-15

    The peak-production rate (peak capacity per unit time) in comprehensive off-line two-dimensional liquid chromatography (LC/x/LC) was optimized for the separation of peptides using poly(styrene-co-divinylbenzene) monolithic columns in the reversed-phase (RP) mode. A first-dimension ((1)D) separation was performed on a monolithic column operating at a pH of 8, followed by sequential analysis of all the (1)D fractions on a monolithic column operating at a pH of 2. To obtain the highest peak-production rate, effects of column length, gradient duration, and sampling time were examined. RP/x/RP was performed at undersampling conditions using a short 10 min (1)D gradient. The peak-production rate was highest using a 50 mm long (2)D column applying an 8-10 min (2)D gradient time and was almost a factor of two higher than when a 250 mm monolithic column was used. The best way to obtain a higher peak-production rate in off-line LC/x/LC proved to be an increase in the number of (1)D fractions collected. Increasing the (2)D gradient time was less effective. The potential of the optimized RP/x/RP method is demonstrated by analyzing proteomics samples of various complexities. Finally, the trade-off between peak capacity and analysis time is discussed in quantitative terms for both one-dimensional RP gradient-elution chromatography and the off-line two-dimensional (RP/x/RP) approach. At the conditions applied, the RP/x/RP approach provided a higher peak-production rate than the (1)D-LC approach when collecting three (1)D fractions, which corresponds to a total analysis time of 60 min.

  12. Novel affinity monolithic column modified with cuprous sulfide nanoparticles for the selective enrichment of low-molecular-weight electron-rich analytes.

    PubMed

    Shan, Yuanhong; Shi, Xianzhe; Xu, Guowang

    2015-03-01

    A novel monolithic column modified with cuprous sulfide nanoparticles was developed and its affinity characteristics towards low-molecular-weight electron-rich analytes were investigated. In the synthesis process, home-made cuprous oxide nanocubes were immobilized on the surface of monolithic skeleton with the moderate thickness based on the strong interaction between imidazole groups and cuprous oxide, then the cuprous oxide layer was transformed into the more stable cuprous sulfide layer through the treatment by sodium sulfide. The resulting cuprous sulfide modified monolithic column presented good permeability and stability in a wide pH range from 2 to 10. Two kinds of typical electron-rich analytes, kanamycin A and purine, were chosen to assess its affinity characteristics. Compared with the commercial Cu(2+) - and Ni(2+) -based affinity sorbents, a larger binding capacity of cuprous sulfide modified column toward kanamycin A was obtained under basic condition and the recovery of kanamycin A in a milk sample was over 70%. Moreover, the binding capacity of cuprous sulfide modified column for purine was up to 5.57 mg/mL in frontal elution mode. These results suggested that the Cu2 S column has a promising application for the enrichment of electron-rich analytes.

  13. Hemoglobin Ypsilanti: a high-oxygen-affinity hemoglobin demonstrated by two automated high-pressure liquid chromatography systems.

    PubMed

    Mais, Daniel D; Boxer, Laurence A; Gulbranson, Ronald D; Keren, David F

    2007-11-01

    Hemoglobin (Hb) Ypsilanti is a rare high-oxygen-affinity hemoglobin. Like other high-oxygen-affinity hemoglobins, Hb Ypsilanti manifests as erythrocytosis. Because the migration of many high-oxygen-affinity variants on alkaline and acid gels does not differ from that of HbA, oxygen-hemoglobin dissociation studies are often used to document their presence. Hb Ypsilanti is a notable exception because its electrophoresis pattern on alkaline gel is highly characteristic, exemplifying the phenomenon of hybrid formation in variant hemoglobins. In the past few years, several laboratories have begun to use high-pressure liquid chromatography (HPLC) as a screen for hemoglobinopathies. We demonstrate the elution profile of Hb Ypsilanti on the 2 most widely used HPLC methods.

  14. Physicochemical and Biological Characterization of Fucoidan from Fucus vesiculosus Purified by Dye Affinity Chromatography

    PubMed Central

    Zayed, Ahmed; Muffler, Kai; Hahn, Thomas; Rupp, Steffen; Finkelmeier, Doris; Burger-Kentischer, Anke; Ulber, Roland

    2016-01-01

    A comparative study concerning the physicochemical, monomeric composition and biological characters among different fucoidan fractions is presented. Common purification techniques for fucoidan usually involve many steps. During these steps, the important structural features might be affected and consequently alter its biological activities. Three purified fractions were derived from Fucus vesiculosus water extract which, afterwards, were purified by a recently-developed dye affinity chromatography protocol. This protocol is based on dye-sulfated polysaccharide interactions. The first two fractions were obtained from crude precipitated fucoidan at different pH values of the adsorption phase: pH 1 and 6. This procedure resulted in fucoidan_1 and 6 fractions. The other, third, fraction: fucoidan_M, however, was obtained from a buffered crude extract at pH 1, eliminating the ethanol precipitation step. All of the three fractions were then further evaluated. Results revealed that fucoidan_M showed the highest sulfur content (S%), 12.11%, with the lowest average molecular weight, 48 kDa. Fucose, galactose, and uronic acid/glucose dimers were detected in all fractions, although, xylose was only detected in fucoidan_1 and 6. In a concentration of 10 µg·mL−1, Fucoidan_6 showed the highest heparin-like anticoagulant activity and could prolong the APTT and TT significantly to 66.03 ± 2.93 and 75.36 ± 1.37 s, respectively. In addition, fucoidan_M demonstrated the highest potency against HSV-1 with an IC50 of 2.41 µg·mL−1. The technique proved to be a candidate for fucoidan purifaction from its crude extract removing the precipitation step from common purification protocols and produced different fucoidan qualities resulted from the different incubation conditions with the immobilized thiazine toluidine blue O dye. PMID:27092514

  15. Physicochemical and Biological Characterization of Fucoidan from Fucus vesiculosus Purified by Dye Affinity Chromatography.

    PubMed

    Zayed, Ahmed; Muffler, Kai; Hahn, Thomas; Rupp, Steffen; Finkelmeier, Doris; Burger-Kentischer, Anke; Ulber, Roland

    2016-04-15

    A comparative study concerning the physicochemical, monomeric composition and biological characters among different fucoidan fractions is presented. Common purification techniques for fucoidan usually involve many steps. During these steps, the important structural features might be affected and consequently alter its biological activities. Three purified fractions were derived from Fucus vesiculosus water extract which, afterwards, were purified by a recently-developed dye affinity chromatography protocol. This protocol is based on dye-sulfated polysaccharide interactions. The first two fractions were obtained from crude precipitated fucoidan at different pH values of the adsorption phase: pH 1 and 6. This procedure resulted in fucoidan_1 and 6 fractions. The other, third, fraction: fucoidan_M, however, was obtained from a buffered crude extract at pH 1, eliminating the ethanol precipitation step. All of the three fractions were then further evaluated. Results revealed that fucoidan_M showed the highest sulfur content (S%), 12.11%, with the lowest average molecular weight, 48 kDa. Fucose, galactose, and uronic acid/glucose dimers were detected in all fractions, although, xylose was only detected in fucoidan_1 and 6. In a concentration of 10 µg·mL(-1), Fucoidan_6 showed the highest heparin-like anticoagulant activity and could prolong the APTT and TT significantly to 66.03 ± 2.93 and 75.36 ± 1.37 s, respectively. In addition, fucoidan_M demonstrated the highest potency against HSV-1 with an IC50 of 2.41 µg·mL(-1). The technique proved to be a candidate for fucoidan purifaction from its crude extract removing the precipitation step from common purification protocols and produced different fucoidan qualities resulted from the different incubation conditions with the immobilized thiazine toluidine blue O dye.

  16. Rapid purification of the gastric H+/K(+)-ATPase complex by tomato-lectin affinity chromatography.

    PubMed Central

    Callaghan, J M; Toh, B H; Simpson, R J; Baldwin, G S; Gleeson, P A

    1992-01-01

    We have previously shown that tomato lectin binds specifically to the 60-90 kDa membrane glycoprotein of parietal cell tubulovesicles, the beta-subunit of the gastric H+/K(+)-ATPase (proton pump) [Callaghan, Toh, Pettitt, Humphris & Gleeson (1990) J. Cell Sci. 95, 563-576; Toh, Gleeson, Simpson, Mortiz, Callaghan, Goldkorn, Jones, Martinelli, Mu, Humphris, Pettitt, Mori, Masuda, Sobieszczuk, Weinstock, Mantamadiotis & Baldwin (1990) Proc. Natl. Acad. Sci. U.S.A. 87, 6418-6422]. Here we have exploited this interaction for the development of a rapid single-step chromatography procedure for the purification of an active pig gastric proton pump complex. Initially, H+/K(+)-ATPase-enriched membranes, prepared from pig gastric microsomes by density-gradient centrifugation, were extracted in 1% Triton X-100 and passed through a 1 ml tomato lectin-Sepharose 4B column. The bound material, eluted with 20 mM-chitotriose, showed a major band with an apparent molecular mass of 95 kDa, and a faint broad band of 60-90 kDa, by SDS/PAGE. N-Glycanase treatment of the bound material resulted in the appearance of a 35 kDa band, the size of the protein core of the 60-90 kDa glycoprotein beta-subunit. The two components were identified as the 95 kDa alpha-subunit and the 60-90 kDa beta-subunit of the gastric H+/K(+)-ATPase, by immunoreactivity with monospecific antibodies, and by tryptic peptide sequences of the tomato-lectin-bound material. The beta-subunit was present in approximately equimolar amounts to the catalytic alpha-subunit. Whereas the gastric H+/K(+)-ATPase was not active after solubilization in 1% Triton X-100, solubilization of density-gradient-purified membranes in the non-ionic detergent, C12E8, followed by chromatography of the extract on tomato lectin-Sepharose 4B, resulted in the purification of the gastric H+/K(+)-ATPase complex which exhibited K(+)-dependent phosphatase activity. This is the first report of a rapid purification of a partially active solubilized

  17. Affinity chromatography of proteins on non-porous copolymerized particles of styrene, methyl methacrylate and glycidyl methacrylate.

    PubMed

    Chen, C H; Lee, W C

    2001-06-29

    Non-porous particles having an average diameter of 2.1 microm were prepared by co-polymerization of styrene, methyl methacrylate and glycidyl methacrylate, which was abbreviated as P(S-MMA-GMA). The particles were mechanically stable due to the presence of benzene rings in the backbone of polymer chains, and could withstand high pressures when a column packed with these particles was operated in the HPLC mode. The polymer particles were advantaged by immobilization of ligands via the epoxy groups on the particle surface that were introduced by one of the monomers, glycidyl methacrylate. As a model system, Cibacron Blue 3G-A was covalently immobilized onto the non-porous copolymer beads. The dye-immobilized P(S-MMA-GMA) particles were slurry packed into a 1.0 cm x 0.46 cm I.D. column. This affinity column was effective for the separation of turkey egg white lysozyme from a protein mixture. The bound lysozyme could be eluted to yield a sharp peak by using a phosphate buffer containing 1 M NaCl. For a sample containing up to 8 microg of lysozyme, the retained portion of proteins could be completely eluted without any slit peak. Due to the use of a shorter column, the analysis time was shorter in comparison with other affinity systems reported in the literature. The retention time could be reduced significantly by increasing the flow-rate, while the capacity factor remained at the same level.

  18. Using Artificial Soil and Dry-Column Flash Chromatography to Simulate Organic Substance Leaching Process: A Colorful Environmental Chemistry Experiment

    ERIC Educational Resources Information Center

    de Avellar, Isa G. J.; Cotta, Tais A. P. G.; Neder, Amarilis de V. Finageiv

    2012-01-01

    Soil is an important and complex environmental compartment and soil contamination contributes to the pollution of aquifers and other water basins. A simple and low-cost experiment is described in which the mobility of three organic compounds in an artificial soil is examined using dry-column flash chromatography. The compounds were applied on top…

  19. Trend analysis of performance parameters of pre-packed columns for protein chromatography over a time span of ten years.

    PubMed

    Scharl, Theresa; Jungreuthmayer, Christian; Dürauer, Astrid; Schweiger, Susanne; Schröder, Tim; Jungbauer, Alois

    2016-09-23

    Pre-packed small scale chromatography columns are increasingly used for process development, for determination of design space in bioprocess development, and for post-licence process verifications. The packing quality of 30,000 pre-packed columns delivered to customers over a period 10 years has been analyzed by advanced statistical tools. First, the data were extracted and checked for inconsistencies, and then were tabulated and made ready for statistical processing using the programming language Perl (https://www.perl.org/) and the statistical computing environment R (https://www.r-project.org/). Reduced HETP and asymmetry were plotted over time to obtain a trend of packing quality over 10 years. The obtained data were used as a visualized coefficient of variation analysis (VCVA), a process that has often been applied in other industries such as semiconductor manufacturing. A typical fluctuation of reduced HETP was seen. A Tsunami effect in manufacturing, the effect of propagation of manufacturing deviations leading to out-of-specification products, was not observed with these pre-packed columns. Principal component analysis (PCA) showed that all packing materials cluster. Our data analysis showed that the current commercially available chromatography media used for biopharmaceutical manufacturing can be reproducibly and uniformly packed in polymer-based chromatography columns, which are designed for ready-to-use purposes. Although the number of packed columns has quadrupled over one decade the packing quality has remained stable.

  20. Optimal performance of single-column chromatography and simulated moving bed processes for the separation of optical isomers

    NASA Astrophysics Data System (ADS)

    Medi, Bijan; Kazi, Monzure-Khoda; Amanullah, Mohammad

    2013-06-01

    Chromatography has been established as the method of choice for the separation and purification of optically pure drugs which has a market size of about 250 billion USD. Single column chromatography (SCC) is commonly used in the development and testing phase of drug development while multi-column Simulated Moving Bed (SMB) chromatography is more suitable for large scale production due to its continuous nature. In this study, optimal performance of SCC and SMB processes for the separation of optical isomers under linear and overloaded separation conditions has been investigated. The performance indicators, namely productivity and desorbent requirement have been compared under geometric similarity for the separation of a mixture of guaifenesin, and Tröger's base enantiomers. SCC process has been analyzed under equilibrium assumption i.e., assuming infinite column efficiency, and zero dispersion, and its optimal performance parameters are compared with the optimal prediction of an SMB process by triangle theory. Simulation results obtained using actual experimental data indicate that SCC may compete with SMB in terms of productivity depending on the molecules to be separated. Besides, insights into the process performances in terms of degree of freedom and relationship between the optimal operating point and solubility limit of the optical isomers have been ascertained. This investigation enables appropriate selection of single or multi-column chromatographic processes based on column packing properties and isotherm parameters.

  1. Analysis of drugs in plasma samples from schizophrenic patients by column-switching liquid chromatography-tandem mass spectrometry with organic-inorganic hybrid cyanopropyl monolithic column.

    PubMed

    Domingues, Diego Soares; Souza, Israel Donizeti de; Queiroz, Maria Eugênia Costa

    2015-07-01

    This study reports on the development of a rapid, selective, and sensitive column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyze sixteen drugs (antidepressants, anticonvulsants, anxiolytics, and antipsychotics) in plasma samples from schizophrenic patients. The developed organic-inorganic hybrid monolithic column with cyanopropyl groups was used for the first dimension of the column-switching arrangement. This arrangement enabled online pre-concentration of the drugs (monolithic column) and their subsequent analytical separation on an XSelect SCH C18 column. The drugs were detected on a triple quadrupole tandem mass spectrometer (multiple reactions monitoring mode) with an electrospray ionization source in the positive ion mode. The developed method afforded adequate linearity for the sixteen target drugs; the coefficients of determination (R(2)) lay above 0.9932, the interassay precision had coefficients of variation lower than 6.5%, and the relative standard error values of the accuracy ranged from -14.0 to 11.8%. The lower limits of quantification in plasma samples ranged from 63 to 1250pgmL(-1). The developed method successfully analyzed the target drugs in plasma samples from schizophrenic patients for therapeutic drug monitoring (TDM).

  2. At-line hyphenation of high-speed countercurrent chromatography with Sephadex LH-20 column chromatography for bioassay-guided separation of antioxidants from vine tea (Ampelopsis grossedentata).

    PubMed

    Ma, Ruyi; Zhou, Rongrong; Tong, Runna; Shi, Shuyun; Chen, Xiaoqing

    2017-01-01

    Vine tea (Ampelopsis grossedentata), a widely used healthy tea, beverage and herbal medicine, exhibited strong antioxidant activity. However, systematic purification of antioxidants, especially for those with similar structures or polarities, is a challenging work. Here, we present a novel at-line hyphenation of high-speed countercurrent chromatography with Sephadex LH-20 column chromatography (HSCCC-Sephadex LH-20 CC) for rapid and efficient separation of antioxidants from vine tea target-guided by 1,1-diphenyl-2-picryl-hydrazyl radical-high performance liquid chromatography (DPPH-HPLC) experiment. A makeup pump, a six-port switching valve and a trapping column were served as interface. The configuration had no operational time and mobile phase limitations between two dimensional chromatography and showed great flexibility without tedious sample-handling procedure. Seven targeted antioxidants were firstly separated by stepwise HSCCC using petroleum ether-ethyl acetate-methanol-water (4:9:4:9, v/v/v/v) and (4:9:5:8, v/v/v/v) as solvent systems, and then co-eluted antioxidants were on-line trapped, concentrated and desorbed to Sephadex LH-20 column for further off-line purification by methanol. It is noted that six elucidated antioxidants with purity over 95% exhibited stronger activity than ascorbic acid (VC). More importantly, this at-line hyphenated strategy could sever as a rapid and efficient pathway for systematic purification of bioactive components from complex matrix.

  3. Evaluation of reversible interconversion in comprehensive two-dimensional gas chromatography using enantioselective columns in first and second dimensions.

    PubMed

    Kröger, Sabrina; Wong, Yong Foo; Chin, Sung-Tong; Grant, Jacob; Lupton, David; Marriott, Philip J

    2015-07-24

    The reversible molecular interconversion behaviour of a synthesised oxime (2-phenylpropanaldehyde oxime; (C6H5)CH(CH3)CHN(OH)) was investigated by both, single dimensional gas chromatography (1D GC) and comprehensive two-dimensional gas chromatography (GC×GC). Previous studies on small molecular weight oximes were extended to this larger aromatic oxime (molar mass 149.19gmol(-1)) with interest in the extent of interconversion, enantioselective resolution, and retention time. On a polyethylene glycol (PEG; wax-type) column, a characteristic interconversion zone between two antipodes of E and Z isomers was formed by molecules which have undergone isomerisation on the column (E⇌Z). The extent of interconversion was investigated by varying chromatographic conditions (oven temperature and carrier flow rate) to understand the nature of the behaviour observed. The extent of interconversion was negligible in both enantioselective and methyl-phenylpolysiloxane phase-columns, correlating with the low polarity of the stationary phase. In order to obtain isomerisation along with enantio-resolution, a wax-type and an enantioselective column were coupled in either enantioselective-wax or wax-enantioselective order. The most appropriate column arrangement was selected for study by using a GC×GC experiment with either a wax-phase or phenyl-methylpolysiloxane phase as (2)D column. In addition to evaluation of these fast elution columns, a long narrow-bore enantioselective column (10m) was introduced as (2)D, providing an enantioselective-PEG (coupled-column ensemble: (1)D1+(1)D2)×enantioselective ((2)D) column combination. In this instance, the (1)D1 enantioselective column provides enantiomeric separation of the corresponding enantiomers ((R) and (S)) of (E)- and (Z)-2-phenylpropanaldehyde oxime, followed by E/Z isomerisation in the coupled (1)D2 PEG (reactor) column. The resulting chromatographic interconversion region was modulated and separated into either E/Z isomers

  4. Hydrophilic interaction chromatography using a meter-scale monolithic silica capillary column for proteomics LC-MS.

    PubMed

    Horie, Kanta; Kamakura, Takeo; Ikegami, Tohru; Wakabayashi, Masaki; Kato, Takashi; Tanaka, Nobuo; Ishihama, Yasushi

    2014-04-15

    A meter-scale monolithic silica capillary column modified with urea-functional groups for hydrophilic interaction liquid chromatography (HILIC) was developed for highly efficient separation of biological compounds. We prepared a ureidopropylsilylated monolithic silica capillary column with a minimum plate height of 12 μm for nucleosides and a permeability of 2.1 × 10(-13) m(2), which is comparable with the parameters of monolithic silica-C18 capillary columns. Over 300,000 theoretical plates were experimentally obtained in HILIC with a 4 m long column at 8 MPa; this is the best result yet reported for HILIC. A 2 m long ureidopropylsilylated monolithic silica capillary column was utilized to develop a HILIC mode LC-MS system for proteomics applications. Using tryptic peptides from human HeLa cell lysate proteins, we identified the comparable numbers of peptides and proteins in HILIC with those in reversed-phase liquid chromatography (RPLC) using a C18-modified monolithic silica column when shallow gradients were applied. In addition, approximately 5-fold increase in the peak response on average was observed in HILIC for commonly identified tryptic peptides due to the high acetonitrile concentration in the HILIC mobile phase. Since HILIC mode LC-MS shows orthogonal selectivity to RPLC mode LC-MS, it is useful as a complementary tool to increase proteome coverage in proteomics studies.

  5. Silica-based monolithic capillary columns modified by liposomes for characterization of analyte-liposome interactions by capillary liquid chromatography.

    PubMed

    Moravcová, Dana; Planeta, Josef; Wiedmer, Susanne K

    2013-11-22

    This study introduces a silica-based monolith in a capillary format (0.1 mm × 100 mm) as a support for immobilization of liposomes and its characterization in immobilized liposome chromatography. Silica-based monolithic capillary columns prepared by acidic hydrolysis of tetramethoxysilane in the presence of polyethylene glycol and urea were modified by (3-aminopropyl)trimethoxysilane, whereby amino groups were introduced to the monolithic surface. These groups undergo reaction with glutaraldehyde to form an iminoaldehyde, allowing covalent binding of pre-formed liposomes containing primary amino groups. Two types of phospholipid vesicles were used for column modification; these were 2-oleoyl-1-palmitoyl-sn-glycero-3-phosphatidyl choline with and without 1,2-diacyl-sn-glycero-3-phospho-L-serine. The prepared columns were evaluated under isocratic separation conditions employing 20mM phosphate buffer at pH 7.4 as a mobile phase and a set of unrelated drugs as model analytes. The liposome layer on the synthesized columns significantly changed the column selectivity compared to the aminopropylsilylated monolithic stationary phase. Monolithic columns modified by liposomes were stable under the separation conditions, which proved the applicability of the suggested preparation procedure for the synthesis of capillary columns dedicated to study analyte-liposome interactions. The column efficiency originating from the silica monolith was preserved and reached, e.g., more than 120,000 theoretical plates/m for caffeine as a solute.

  6. Determination of biogenic amines in beer with pre-column derivatization by high performance liquid chromatography.

    PubMed

    Tang, Tao; Shi, Tianyu; Qian, Kun; Li, Pingliang; Li, Jianqiang; Cao, Yongsong

    2009-02-15

    Eighteen samples of commercially available Chinese beer were analyzed in order to determine the content of biogenic amines. The method involves pre-column derivatization of the amines with 4-chloro-3,5-dinitrobenzotrifluoride (CNBF) and subsequent analysis by RP-HPLC (reversed phase-high performance liquid chromatography) with diode array detection. The labeled biogenic amines were separated on a Kromasil C18 column (250mmx4.6mm, 5microm) at room temperature and UV detection was applied at 254nm. The separation of seven labeled biogenic amines was achieved within 22min by elution acetonitrile and HAc-NaAc buffers. The method linearity, calculated for each biogenic amine, has a correlation coefficient higher than 0.9925, in concentrations ranging from 2.9micromolL(-1) to 565micromolL(-1). Detection limits of biogenic amines were 0.056-0.87micromolL(-1), at a signal-to-noise ratio of 3. The proposed method has been applied to the quantitative determination of spermine, phenethylamine, spermidine, histamine, tyramine, tryptamine and putrescine in beer with recoveries of 91.9-103.1% and R.S.D. of 2.86-5.63%. Quantitation is relative to external standards. The results showed that each kind of beer examined contained at least three biogenic amines. Putrescine, histamine and tyramine were detected in all samples. Spermidine was detected in 89% of the beers. Spermine, tryptamine and phenylethylamine occurred in 78%, 61% and 44% of the beers examined, respectively. These levels were below the level that may elicit direct adverse reactions for most consumers.

  7. Are molecular weights of proteins determined by superose 12 column chromatography correct?

    PubMed

    Lee, Shih-Chieh; Whitaker, John R

    2004-08-11

    Our research on several proteins indicates that accurate molecular weights cannot be determined by Superose 12 column chromatography. In support of this statement, we present data on molecular weights of purified red kidney bean alpha-amylase inhibitor (RKB alphaAI) and white kidney bean alpha-amylase inhibitor (WKB alphaAI) to document this problem. The molecular weight of purified RKB alphaAI determined by Sephadex G-100 gel filtration, polyacrylamide gel electrophoresis, Superose 12 gel filtration and cDNA were 49.0, 51.0, 22.9, and 49.805 kDa (not glycosylated), respectively. The molecular weights of WKB alphaAI by several methods were as follows: Sephadex G-100 gel filtration, 51.0 kDa; Superose 12 gel filtration in 0.2 M NaCl buffer, 23.1 kDa; polyacrylamide gel electrophoresis (PAGE), 51.0 kDa; sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), 45.0 kDa; multiangle laser light scattering (MALLS), 49.940 kDa; laser-assisted time-of-flight mass spectrometry (LATOFMS), 56.714 kDa; and cDNA sequence (with 12.2% carbohydrate), 55.9 kDa. The data indicate there is ionic interaction between proteins and the matrix of Superose 12 in low ionic strength buffers and hydrophobic interaction at higher ionic strength buffers. Researchers should be cautious when using Superose 12 columns for molecular weight determinations.

  8. G-quadruplex on oligo affinity support (G4-OAS): an easy affinity chromatography-based assay for the screening of G-quadruplex ligands.

    PubMed

    Musumeci, Domenica; Amato, Jussara; Randazzo, Antonio; Novellino, Ettore; Giancola, Concetta; Montesarchio, Daniela; Pagano, Bruno

    2014-05-06

    A simple, cheap, and highly reproducible affinity chromatography-based method has been developed for the screening of G-quadruplex binders. The tested compounds were flowed through a polystyrene resin functionalized with an oligonucleotide able to form, in proper conditions, a G-quadruplex structure. Upon cation-induced control of the folding/unfolding processes of the immobilized G-quadruplex-forming sequence, small molecules specifically interacting with the oligonucleotide structure were first captured and then released depending on the used working solution. This protocol, first optimized for different kinds of known G-quadruplex ligands and then applied to a set of putative ligands, has allowed one to fully reuse the same functionalized resin batch, recycled for several tens of experiments without loss in efficiency and reproducibility.

  9. Analysis of Free Drug Fractions in Serum by Ultrafast Affinity Extraction and Two-Dimensional Affinity Chromatography using α1-Acid Glycoprotein Microcolumns

    PubMed Central

    Bi, Cong; Zheng, Xiwei; Hage, David S.

    2016-01-01

    In the circulatory system, many drugs are reversibly bound to serum proteins such as human serum albumin (HSA) and alpha1-acid glycoprotein (AGP), resulting in both free and protein-bound fractions for these drugs. This report examined the use of microcolumns containing immobilized AGP for the measurement of free drug fractions by ultrafast affinity extraction and a two-dimensional affinity system. Several drugs known to bind AGP were used as models to develop and evaluate this approach. Factors considered during the creation of this method included the retention of the drugs on the microcolumns, the injection flow rate, the microcolumn size, and the times at which a second AGP column was placed on-line with the microcolumn. The final system had residence times of only 110–830 ms during sample passage through the AGP microcolumns and allowed free drug fractions to be determined within 10–20 min when using only 3–10 µL of sample per injection. This method was used to measure the free fractions of the model drugs at typical therapeutic levels in serum, giving good agreement with the results obtained by ultrafiltration. This approach was also used to estimate the binding constants for each drug with AGP in serum, even for drugs that had significant interactions with both AGP and HSA in such samples. These results indicated that AGP microcolumns could be used with ultrafast affinity extraction to measure free drug fractions in a label-free manner and to study the binding of drugs with AGP in complex samples such as serum. PMID:26797422

  10. Factors influencing the separation of oligonucleotides using reversed-phase/ion-exchange mixed-mode high performance liquid chromatography columns.

    PubMed

    Biba, Mirlinda; Jiang, Eileen; Mao, Bing; Zewge, Daniel; Foley, Joe P; Welch, Christopher J

    2013-08-23

    New mixed-mode columns consisting of reversed-phase and ion-exchange separation modes were evaluated for the analysis of short RNA oligonucleotides (∼20mers). Conventional analysis for these samples typically involves using two complementary methods: strong anion-exchange liquid chromatography (SAX-LC) for separation based on charge, and ion-pair reversed-phase liquid chromatography (IP-RPLC) for separation based on hydrophobicity. Recently introduced mixed-mode high performance liquid chromatography (HPLC) columns combine both reversed-phase and ion-exchange modes, potentially offering a simpler analysis by combining the benefits of both separation modes into a single method. Analysis of a variety of RNA oligonucleotide samples using three different mixed-mode stationary phases showed some distinct benefits for oligonucleotide separation and analysis. When using these mixed-mode columns with typical IP-RPLC mobile phase conditions, such as ammonium acetate or triethylammonium acetate as the primary ion-pair reagent, the separation was mainly based on the IP-RPLC mode. However, when changing the mobile phase conditions to those more typical for SAX-LC, such as salt gradients with NaCl or NaBr, very different separation patterns were observed due to mixed-mode interactions. In addition, the Scherzo SW-C18 and SM-C18 columns with sodium chloride or sodium bromide salt gradients also showed significant improvements in peak shape.

  11. A reduced order model for the study of asymmetries in linear gas chromatography for homogeneous tubular columns.

    SciTech Connect

    Whiting, Joshua J.; Romero, Louis Anthony; Parks, Michael L.

    2005-08-01

    In gas chromatography, a chemical sample separates into its constituent components as it travels along a long thin column. As the component chemicals exit the column they are detected and identified, allowing the chemical makeup of the sample to be determined. For correct identification of the component chemicals, the distribution of the concentration of each chemical along the length of the column must be nearly symmetric. The prediction and control of asymmetries in gas chromatography has been an active research area since the advent of the technique. In this paper, we develop from first principles a general model for isothermal linear chromatography. We use this model to develop closed-form expressions for terms related to the first, second, and third moments of the distribution of the concentration, which determines the velocity, diffusion rate, and asymmetry of the distribution. We show that for all practical experimental situations, only fronting peaks are predicted by this model, suggesting that a nonlinear chromatography model is required to predict tailing peaks. For situations where asymmetries arise, we analyze the rate at which the concentration distribution returns to a normal distribution. Numerical examples are also provided.

  12. Novel approach to determine ghrelin analogs by liquid chromatography with mass spectrometry using a monolithic column.

    PubMed

    Zemenova, Jana; Sykora, David; Adamkova, Hana; Maletinska, Lenka; Elbert, Tomas; Marek, Ales; Blechova, Miroslava

    2017-03-01

    In our project, ghrelin analogs possessing enhanced stability and potential to significantly increase food intake were used. Three newly synthesized ghrelin analogs with fatty acid residues consisting of 8, 10, and 14 carbon atoms were studied. The main goal of this work was to develop a suitable analytical method for the determination of the stability of the novel ghrelin analogs in plasma. An appropriate liquid chromatography-mass spectrometry method was developed and optimized. The results obtained were compared with the data measured by using a commercial enzyme-linked immunosorbent assay kit, and a good correlation was found. A preparation strategy for plasma samples was optimized and consisted of simple dilution of the plasma samples followed by direct injection onto a very short monolithic column in combination with mass spectrometric detection. The developed analytical method was utilized for the determination of the stability of the prepared lipopeptides in plasma and for the quantification of the lipopeptides in a preliminary pharmacokinetic study. The feasibility of the developed separation method was clearly demonstrated. Accuracy and precision were within 80-120% and ±20% limits, respectively. Calibration curves were constructed in the range of 1-250 μg/mL.

  13. Fabrication of electrolytic cell for online post-column electrochemical derivatization in ion chromatography.

    PubMed

    Wu, Shuchao; Xu, Wei; Yang, Bingcheng; Ye, Mingli; Zhang, Peimin; Shen-Tu, Chao; Zhu, Yan

    2012-07-20

    An electrolytic cell (EC), composed of two ruthenium-plated titanium electrodes separated by cation-exchange membranes, was fabricated and evaluated for online postcolumn derivatization in ion chromatography (IC). Folic acid (FA) and methotrexate (MTX) were preliminarily used as prototype analytes to test the performance of EC. After separation by an anion exchange column, FA and MTX, which emit very weak fluorescence when excited, were electrochemically oxidized online in the anode chamber of the EC. The compounds with strong fluorescence, which are oxidation products, were detected by the fluorescence detector. The phosphate buffer solution (100 mM KH(2)PO(4)) served as an optimal eluent for anion exchange chromatographic separation and a suitable supporting electrolyte for electro-oxidation, leading to ideal compatibility between IC separation and the postcolumn electrochemical derivatization. For the presently proposed method, the linear ranges were from 0.01 mg L(-1) to 5 mg L(-1) for both FA and MTX. The detection limits of FA and MTX were 1.8 and 2.1 μg L(-1), and the relative standard deviations (RSD, n=7) were 2.9% and 3.6%, respectively. The method was applied for the simultaneous determination of FA and MTX in the plasma of patients being treated for rheumatoid arthritis. The determination of MTX in the urine of the patients of diffuse large B cell lymphoma was also demonstrated.

  14. Half-width plots, a simple tool to predict peak shape, reveal column kinetics and characterise chromatographic columns in liquid chromatography: state of the art and new results.

    PubMed

    Baeza-Baeza, J J; Ruiz-Ángel, M J; García-Álvarez-Coque, M C; Carda-Broch, S

    2013-11-01

    Peak profiles in chromatography are characterised by their height, position, width and asymmetry; the two latter depend on the values of the left and right peak half-widths. Simple correlations have been found between the peak half-widths and the retention times. The representation of such correlations has been called half-width plots. For isocratic elution, the plots are parabolic, although often, the parabolas can be approximated to straight-lines. The plots can be obtained with the half-widths/retention time data for a set of solutes experiencing the same kinetics, eluted with a mobile phase at fixed or varying composition. When the analysed solutes experience different resistance to mass transfer, the plots will be solute dependent, and should be obtained with the data for each solute eluted with mobile phases at varying composition. The half-width plots approach is a simple tool that facilitates the prediction of peak shape (width and asymmetry) with optimisation purposes, reveal the interaction kinetics of solutes in different columns, and characterise chromatographic columns. This work shows half-width plots for different situations in isocratic elution, including the use of different flows, the effect of temperature, the modification of the stationary phase surface by an additive, the existence of specific interactions within the column, and the comparison of columns. The adaptation to gradient elution is also described. Previous knowledge on half-width plots is structured and analysed, to which new results are added.

  15. Application of coupled-column liquid chromatography combined with post-column photochemically induced fluorimetry derivatization and fluorescence detection to the determination of pyrethroid insecticides in vegetable samples.

    PubMed

    Parrilla Vázquez, P; Gil García, M D; Barranco Martínez, D; Martínez Galera, M

    2005-03-01

    This study reports the first application of coupled-column liquid chromatography-photochemically induced fluorimetry-fluorescence detection (LC-LC-PIF-FD), demonstrating its potential for the quantitative and selective detection of seven pyrethroids in vegetable samples such as cucumber, green bean, tomato and aubergine. An internal surface reversed-phase (ISRP) column coupled to a C18 column for analyte clean-up and determination were used, respectively. In comparison with a C18 column, the ISRP substantially improved the separation between analytes and interferences from the vegetable matrix. The limits of detection ranged from 0.01 to 0.22 microg kg(-1) in the vegetable samples (equivalent to 0.01 and 0.13 microg L(-1) in the extract injected), and limits of determination ranged from 0.56 to 8.33 microg kg(-1) in the vegetable samples (equivalent to 0.34 and 5.00 microg L(-1) in the extract injected). Samples were extracted into dichloromethane to yield mean recoveries at two levels of concentration between 72.8 and 110.0% in all cases. Relative standard deviations were lower than 11%.

  16. Two-column sequential injection chromatography--new approach for fast and effective analysis and its comparison with gradient elution chromatography.

    PubMed

    Chocholous, Petr; Satínský, Dalibor; Sklenárová, Hana; Solich, Petr

    2010-05-23

    This work presents novel approach in low-pressure chromatography flow systems--two-column Sequential Injection Chromatography (2-C SIC) and its comparison with gradient elution chromatography on the same instrument. The system was equipped with two different chromatographic columns (connected to selection valve in parallel design) for isocratic separation and determination of all components in composed anti-inflammatory pharmaceutical preparation (tablets). The sample was first injected on the first column of length 30 mm where less retained analytes were separated and then the sample was injected on the second column of length 10 mm where more retained analytes were separated. The SIC system was based on a commercial SIChrom manifold (8-port high-pressure selection valve and medium-pressure syringe pump with 4 mL reservoir) (FIAlab, USA) with two commercially available monolithic columns the "first column" Chromolith Flash RP-18e (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.) and the "second column" Chromolith RP-18e (10 mm x 4.6 mm i.d.) and CCD UV-vis detector USB 4000 with micro-volume 1.0 cm Z flow cell. Two mobile phases were used for analysis (one for each column). The mobile phase 1 used for elution of paracetamol, caffeine and salicylic acid (internal standard) was acetonitrile/water (10:90, v/v, the water part of pH 3.5 adjusted with acetic acid), flow rate was 0.9 mL min(-1) (volume 3.0 mL of mobile phase per analysis). The mobile phase 2 used for elution of propyphenazone was acetonitrile/water (30:70, v/v); flow rate was 1.2 mL min(-1) (volume 1.5 mL of mobile phase per analysis). Absorbance was monitored at 210 nm. Samples were prepared by dissolving of one tablet in 30% acetonitrile and 10 microL of filtered supernatant was injected on each column (2 x 10 microL). The chromatographic resolution between all compounds was >1.45 and analysis time was 5.5 min under the optimal conditions. Limits of detection were determined at 0.4 microg m

  17. Greener liquid chromatography using a guard column with micellar mobile phase for separation of some pharmaceuticals and determination of parabens.

    PubMed

    Youngvises, Napaporn; Chaida, Thanatcha; Khonyoung, Supada; Kuppithayanant, Nattawan; Tiyapongpattana, Warawut; Itharat, Arunporn; Jakmunee, Jaroon

    2013-03-15

    In this research, a greener chromatography employing a short column, Zorbax SB C18 cartridge (12.5 × 4.6 mm, 5 μm) commonly used as a guard column in a reverse phase high performance liquid chromatography (RP-HPLC), was utilized as the analytical column in conjunction with a more eco-friendly micellar mobile phase of sodium dodecyl sulfate (SDS) for separation tertiary mixtures of local anesthetics and antihistamines; and binary mixture of colds drugs; and quaternary mixture of some parabens with different separation conditions. The chromatographic behavior of these analytes was studied to demonstrate separation efficiency of this guard column in a micellar mobile phase. Moreover, this column and SDS mobile phase was exploited for determination of parabens in 64 samples of cosmetic product, both those that were produced locally in the community and those that were commercially manufactured. Linear calibration graphs of the parabens as detected at 254 nm were obtained in the range of 1-100 μmol L(-1) with R(2)>0.9990. Percentage recoveries were 92.4-109.2 with %RSD<3, and the limit of detection and quantitation were 0.04-0.10 and 0.20-0.80 μmol L(-1), respectively. This analytical system is not only greener but also faster and employing simpler sample preparation than a conventional liquid chromatographic system.

  18. On-column refolding of denatured lysozyme by the conjoint chromatography composed of SEC and immobilized recombinant DsbA.

    PubMed

    Luo, Man; Guan, Yi-Xin; Yao, Shan-Jing

    2011-10-15

    DsbA (disulfide bond formation protein A) located in the periplasm of Escherichia coli is a disulfide isomerase, which is vital to disulfide bonds formation directly affecting the nascent peptides folding to the correct conformation. In this paper, recombinant DsbA was firstly immobilized onto NHS-activated Sepharose Fast Flow gel. Then Sephadex G-100 gel was sequentially packed on the top of recDsbA Sepharose Fast Flow, and a so-called conjoint chromatography column composed of SEC and immobilized recombinant DsbA was constructed. Denatured lysozyme was applied on the conjoint column. The effect of SEC volume, flow rate, loading amount and volume, pre-equilibrium mode and KCl concentration in the buffer on lysozyme refolding were investigated in detail and the stability of DsbA immobilization was evaluated. Finally the reusability of the conjoint refolding column was also tested. When loading 2.4 mg denatured lysozyme in 0.5 ml solution, the activity recovery reached 92.7% at optimized experimental conditions, and the conjoint column renaturation capacity decreased only 7.7% after six run reuse due to the use of SEC section in the chromatographic refolding process. The conjoint chromatography offers an efficient strategy to refold proteins in vitro with high productivity and column reusability.

  19. High-performance liquid chromatography separation of unsaturated organic compounds by a monolithic silica column embedded with silver nanoparticles.

    PubMed

    Zhu, Yang; Morisato, Kei; Hasegawa, George; Moitra, Nirmalya; Kiyomura, Tsutomu; Kurata, Hiroki; Kanamori, Kazuyoshi; Nakanishi, Kazuki

    2015-08-01

    The optimization of a porous structure to ensure good separation performances is always a significant issue in high-performance liquid chromatography column design. Recently we reported the homogeneous embedment of Ag nanoparticles in periodic mesoporous silica monolith and the application of such Ag nanoparticles embedded silica monolith for the high-performance liquid chromatography separation of polyaromatic hydrocarbons. However, the separation performance remains to be improved and the retention mechanism as compared with the Ag ion high-performance liquid chromatography technique still needs to be clarified. In this research, Ag nanoparticles were introduced into a macro/mesoporous silica monolith with optimized pore parameters for high-performance liquid chromatography separations. Baseline separation of benzene, naphthalene, anthracene, and pyrene was achieved with the theoretical plate number for analyte naphthalene as 36,000 m(-1). Its separation function was further extended to cis/trans isomers of aromatic compounds where cis/trans stilbenes were chosen as a benchmark. Good separation of cis/trans-stilbene with separation factor as 7 and theoretical plate number as 76,000 m(-1) for cis-stilbene was obtained. The trans isomer, however, is retained more strongly, which contradicts the long- established retention rule of Ag ion chromatography. Such behavior of Ag nanoparticles embedded in a silica column can be attributed to the differences in the molecular geometric configuration of cis/trans stilbenes.

  20. Purification of chimeric heavy chain monoclonal antibody EG2-hFc using hydrophobic interaction membrane chromatography: an alternative to protein-A affinity chromatography.

    PubMed

    Sadavarte, Rahul; Spearman, Maureen; Okun, Natalie; Butler, Michael; Ghosh, Raja

    2014-06-01

    Heavy chain monoclonal antibodies are being considered as alternative to whole-IgG monoclonal antibodies for certain niche applications. Protein-A chromatography which is widely used for purifying IgG monoclonal antibodies is also used for purifying heavy chain monoclonal antibodies as these molecules possess fully functional Fc regions. However, the acidic conditions used to elute bound antibody may sometimes also leach protein-A, which is immunotoxic. Low pH conditions also tend to make the mAb molecules unstable and prone to aggregation. Moreover, protein-A affinity chromatography does not remove aggregates already present in the feed. Hydrophobic interaction membrane chromatography (or HIMC) has already been studied as an alternative to protein-A chromatography for purifying whole-IgG monoclonal antibodies. This paper describes the use of HIMC for capturing a humanized chimeric heavy chain monoclonal antibody (EG2-hFC). Binding and eluting conditions were suitably optimized using pure EG2-hFC. Based on this, an HIMC method was developed for capture of EG2-hFC directly from cell culture supernatant. The EG2-hFc purity obtained in this single-step process was high. The glycan profiles of protein-A and HIMC purified monoclonal antibody samples were similar, clearly demonstrating that both techniques captured similarly glycosylated population of EG2-hFc. Moreover, this technique was able to resolve aggregates from monomeric form of the EG2-hFc.

  1. Copper(II)-based metal affinity chromatography for the isolation of the anticancer agent bleomycin from Streptomyces verticillus culture.

    PubMed

    Gu, Jiesi; Codd, Rachel

    2012-10-01

    The glycopeptide-based bleomycins are structurally complex natural products produced by Streptomyces verticillus used in combination therapy against testicular and other cancers. Bleomycin has a high affinity towards a range of transition metal ions with the 1:1 Fe(II) complex relevant to its mechanism of action in vivo and the 1:1 Cu(II) complex relevant to its production from culture. The affinity between Cu(II) and bleomycin was the underlying principle for using Cu(II)-based metal affinity chromatography in this work to selectively capture bleomycin from crude S. verticillus culture. A solution of standard bleomycin was retained at a binding capacity of 300 nmol mL(-1) on a 1-mL bed volume of Cu(II)-loaded iminodiacetate (IDA) resin at pH 9 via the formation of the heteroleptic immobilized complex [Cu(IDA)(bleomycin)]. Bleomycin was eluted from the resin at pH 5 as the metal-free ligand under conditions where pK(a) (IDA)affinity chromatography as a green chemistry platform for streamlined access to this high-value therapeutic agent.

  2. Rapid purification of mitochondrial hexokinase from rat brain by a single affinity chromatography step on Affi-Gel blue.

    PubMed

    Wilson, J E

    1989-01-01

    The mitochondrial hexokinase from rat brain, selectively released from mitochondria by the action of glucose 6-phosphate, can be purified to greater than 90% homogeneity by a single affinity chromatography step on Affi-Gel Blue; the Cibacron Blue F3GA ligand bound to this matrix serves as an analog of ATP, the normal substrate for the enzyme, and selective elution is accomplished using glucose 6-phosphate which is a competitive ligand vs. ATP. With this and other modifications to the previously described procedure highly purified enzyme is readily obtained in good yield and with retention of the ability to rebind to mitochondria.

  3. The antigenicity in guinea pigs and monkeys of three mycobacterial polysaccharides purified by affinity chromatography with concanavalin A.

    PubMed

    Daniel, T M

    1975-06-01

    The antigenicity of 3 polysaccharides purified from culture filtrates of Mycobacterim tuberculosis by affinity chromatography using a concanavalin A-agarose absorbent was studied. All 3 purified polysaccharides were found to be potent elicitors of delayed skin test reactions in sensitized guinea pigs and in a tuberculos monkey. This antigenicity could not be attributed to contaminating protein. Small dermal reactions were also observed in control guinea pigs. All 3 polysaccharides reacted with precipitating antibody in guinea pig sera, the antigenic specificity observed with the guinea pig sera differing from that demonstrated with reference goat antiserum. The 3 polysaccharides were also demonstrated to contain hemagglutination antigenic sites.

  4. Study on the Alkaloids in Tibetan Medicine Aconitum pendulum Busch by HPLC-MSn Combined with Column Chromatography.

    PubMed

    Wang, Beibei; Dong, Jie; Ji, Jiaojiao; Yuan, Jiang; Wang, Jiali; Wu, Jiarui; Tan, Peng; Liu, Yonggang

    2016-01-01

    A rapid, convenient and effective identification method of alkaloids was established and an attempt on isolating and analyzing the alkaloids in Aconitum pendulum Busch was conducted successfully. In this article, four high-content components including deoxyaconitine, benzoylaconine, aconine and neoline were isolated by using column chromatography. HPLC-MS(n)was employed to deduce the regulations of fragmentation of diterpenoid alkaloids which displayed a characteristic behavior of loss of CO(28u), CH3COOH(60u), CH3OH(32u), H2O(18u) and C6H5COOH(122u). Then, according to fragmentation regulation of mass spectrometry, 42 alkaloids were found inA. pendulum Among them, 38 compounds were identified and 29 alkaloids were reported for the first time for this herb. Therefore, this means that HPLC-MS(n)combined with column chromatography could work as an effective and reliable tool for rapid identification of the chemical components of herbal medicine.

  5. Determination of dissolved bromate in drinking water by ion chromatography and post column reaction: interlaboratory study.

    PubMed

    Cordeiro, Fernando; Robouch, Piotr; de la Calle, Maria Beatriz; Emteborg, Håkan; Charoud-Got, Jean; Schmitz, Franz

    2011-01-01

    A collaborative study, International Evaluation Measurement Programme-25a, was conducted in accordance with international protocols to determine the performance characteristics of an analytical method for the determination of dissolved bromate in drinking water. The method should fulfill the analytical requirements of Council Directive 98/83/EC (referred to in this work as the Drinking Water Directive; DWD). The new draft standard method under investigation is based on ion chromatography followed by post-column reaction and UV detection. The collaborating laboratories used the Draft International Organization for Standardization (ISO)/Draft International Standard (DIS) 11206 document. The existing standard method (ISO 15061:2001) is based on ion chromatography using suppressed conductivity detection, in which a preconcentration step may be required for the determination of bromate concentrations as low as 3 to 5 microg/L. The new method includes a dilution step that reduces the matrix effects, thus allowing the determination of bromate concentrations down to 0.5 microg/L. Furthermore, the method aims to minimize any potential interference of chlorite ions. The collaborative study investigated different types of drinking water, such as soft, hard, and mineral water. Other types of water, such as raw water (untreated), swimming pool water, a blank (named river water), and a bromate standard solution, were included as test samples. All test matrixes except the swimming pool water were spiked with high-purity potassium bromate to obtain bromate concentrations ranging from 1.67 to 10.0 microg/L. Swimming pool water was not spiked, as this water was incurred with bromate. Test samples were dispatched to 17 laboratories from nine different countries. Sixteen participants reported results. The repeatability RSD (RSD(r)) ranged from 1.2 to 4.1%, while the reproducibility RSD (RSDR) ranged from 2.3 to 5.9%. These precision characteristics compare favorably with those of ISO

  6. [Prospects of application of the chitin-binding domains to isolation and purification of recombinant proteins by affinity chromatography: a review].

    PubMed

    Kurek, D V; Lopatin, S A; Varlamov, V P

    2009-01-01

    Properties of substrate-binding domains, some parameters of affinity sorbents, and a number of other special features that were necessary to take into account during creation of chromatographic system for isolation and purification of proteins with incorporated chitin-binding domain were discussed in this review. This method was shown to be successfully used along with metal-chelate affinity chromatography. The metal-chelate affinity chromatography with the use of polyhistidine peptides as affinity labels is successfully applied to isolation, purification, and investigation of recombinant proteins. However, this system had some disadvantages. At present, scientists attracted more and more attention to substrate-binding domains, including those chitin-binding, because they had a number of advantages being used as affinity label.

  7. Simultaneous determination of methamphetamine and its metabolite, amphetamine, in urine using a high performance liquid chromatography column-switching method.

    PubMed

    Kumihashi, Mitsuru; Ameno, Kiyoshi; Shibayama, Takayuki; Suga, Keisuke; Miyauchi, Hiroshi; Jamal, Mostofa; Wang, Weihuan; Uekita, Ikuo; Ijiri, Iwao

    2007-01-01

    We describe here a simple, precise, and highly sensitive method for the simultaneous determination of methamphetamine (MA) and amphetamine (AM) in urine using a high performance liquid chromatography (HPLC) column-switching method. A PK-2A (Shodex) column was used for extraction and deproteinization, and a CAPCELL PAK SCX semi-micro, polymer-coated cation-exchange column was employed for separation. The urine sample was mixed with an equal volume of borate buffer (0.1M, pH 9.4), and then 100 microl of the mixture was injected into the HPLC column. The column was switched for 6 min, and then 10 min later detection was performed at 210 nm. Recovery yields of the MA and AM spiked in the urine were 93.0-100.4% with a coefficient of variation of less than 1%. The calibration curves of MA and AM were in the range of 0.1-10 microg/ml with good linearity (r(2)=0.999), with the limit of qualification being 0.005 microg/ml. This method of using HPLC with column-switching can be used for both qualification and quantification of MA and its metabolite, AM, in urine, especially in forensic cases.

  8. Separation of hexabromocyclododecane diastereomers: Application of C18 and phenyl-hexyl ultra-performance liquid chromatography columns.

    PubMed

    Baek, Song-Yee; Lee, Sunyoung; Kim, Byungjoo

    2017-03-10

    This study was performed to establish the proper liquid chromatographic conditions for the separation of hexabromocyclododecane (HBCD) diastereomers. Column selectivity towards HBCD diastereomers was evaluated for C18 and phenyl-hexyl stationary phases. First, the baseline separation of the primary HBCDs (α-, β-, and γ-HBCD) was obtained using the ultra-performance liquid chromatography (UPLC) column with C18 stationary phase chosen in most previous studies for HBCD analysis; however, co-elution of δ- and ε-HBCD with the primary HBCD diastereomers was observed. To prevent the interference from δ- and ε-HBCD, we adopted a phenyl-hexyl UPLC column to resolve the HBCD diastereomers. The phenyl-hexyl UPLC column showed significantly different selectivity for the HBCD diastereomers compared with the C18 column, which allowed the clear isolation of δ-HBCD and ε-HBCD from the primary HBCD diastereomers. In addition, by checking the retention times of all HBCD diastereomers using both C18 and phenyl-hexyl columns, we confirmed the presence of δ-, ε-, η-, and θ-HBCDs in two technical HBCD mixtures.

  9. Characterization by the solvation parameter model of the retention properties of commercial ionic liquid columns for gas chromatography.

    PubMed

    Rodríguez-Sánchez, S; Galindo-Iranzo, P; Soria, A C; Sanz, M L; Quintanilla-López, J E; Lebrón-Aguilar, R

    2014-01-24

    For the first time, four commercial ionic liquid columns (SLB-IL59, SLB-IL76, SLB-IL82 and SLB-IL100) for gas chromatography have been comprehensively evaluated in terms of efficiency, polarity and solvation properties. Grob tests and McReynolds constants showed that they were all high-efficiency columns of high polarity, but with low inertness to compounds with hydrogen bonding capabilities. The solvation parameter model was used to characterize the solvation interactions of the four columns in the 80-160°C temperature range. Results revealed that all the ionic liquids studied can be considered moderately hydrogen-bond acid and highly cohesive stationary phases, on which the dominant contributions to retention were the dipolar-type and hydrogen-bond base interactions, while π-π and n-π interactions were barely significant. The SLB-IL59 column provided the best separation of homologs, while the SLB-IL76 and SLB-IL100 columns had the most basic and the most acidic phases, respectively. A principal component analysis for the commonly used stationary phases in capillary GC showed that these commercial ionic liquid columns fill an empty area of the available selectivity space, which clearly enhances the separation capacity of this technique.

  10. Radial heterogeneity of some analytical columns used in high-performance liquid chromatography

    SciTech Connect

    Mriziq, Khaled S; Guiochon, Georges A

    2009-01-01

    An on-column electrochemical microdetector was used to determine accurately the radial distribution of the mobile phase velocity and of the column efficiency at the exit of three common analytical columns, namely a 100 mm x 4.6 mm C18 bonded silica-based monolithic column, a 150 mm x 4.6 mm column packed with 2.7 {micro}m porous shell particles of C18 bonded silica (HALO), and a 150 mm x 4.6 mm column packed with 3 {micro}m fully porous C18 bonded silica particles (LUNA). The results obtained demonstrate that all three columns are not radially homogeneous. In all three cases, the efficiency was found to be lower in the wall region of the column than in its core region (the central core with a radius of 1/3 the column inner radius). The decrease in local efficiency from the core to the wall regions was lower in the case of the monolith (ca. 25%) than in that of the two particle-packed columns (ca. 35-50%). The mobile phase velocity was found to be ca. 1.5% higher in the wall than in the core region of the monolithic column while, in contrast, it was ca. 2.5-4.0% lower in the wall region for the two particle-packed columns.

  11. Determination of chlorophylls in Taraxacum formosanum by high-performance liquid chromatography-diode array detection-mass spectrometry and preparation by column chromatography.

    PubMed

    Loh, Chin Hoe; Inbaraj, Baskaran Stephen; Liu, Man Hai; Chen, Bing Huei

    2012-06-20

    Taraxacum formosanum, a well-known Chinese herb shown to be protective against hepatic cancer as well as liver and lung damage, may be attributed to the presence of abundant carotenoids and chlorophylls. However, the variety and content of chlorophylls remain uncertain. The objectives of this study were to develop an high-performance liquid chromatography-diode array detection-mass spectrometry method for determination of chlorophylls in T. formosanum and preparation by column chromatography. An HyPURITY C18 column and a gradient mobile phase of water (A), methanol (B), acetonitrile (C), and acetone (D) could resolve 10 chlorophylls and an internal standard Fast Green FCF within 30 min with a flow rate at 1 mL/min and detection at 660 nm. Both chlorophylls a and a' were present in the largest amount (1389.6 μg/g), followed by chlorophylls b and b' (561.2 μg/g), pheophytins a and a' (31.7 μg/g), hydroxychlorophyll b (26.5 μg/g), hydroxychlorophylls a and a' (9.8 μg/g), and chlorophyllides a and a' (0.35 μg/g). A glass column containing 52 g of magnesium oxide-diatomaceous earth (1:3, w/w) could elute chlorophylls with 800 mL of acetone containing 50% ethanol at a flow rate of 10 mL/min. Some new chlorophyll derivatives including chlorophyllide b, pyropheophorbide b, hydroxypheophytin a, and hydroxypheophytin a' were generated during column chromatography but accompanied by a 63% loss in total chlorophylls. Thus, the possibility of chlorophyll fraction prepared from T. formosanum as a raw material for future production of functional food needs further investigation.

  12. [High-performance liquid chromatography determination of histamine in nasal mucosa of guinea pig after post-column derivatization].

    PubMed

    Huang, X H; Chen, B M; Liang, S X; Deng, F L

    2000-06-28

    A rapid and simple method for determining histamine by post-column derivatization liquid chromatography with fluorescent detection was described. SCX weakly acidic cation exchange column was used as an analytical column. Histamine was eluted at 13 min 12 s by 40 mmol.L-1 of trisodium citrate (pH5.50) at flow rate of 1.0 ml.min-1. The recoveries of histamine ranged from 1.0 mumol.L-1 to 100 mumol.L-1 were above 92%. The detection limit for histamine was 50 nmol.L-1 and the linear range for histamine was 50 nmol.L(-1)-500 mumol.L-1.

  13. Analysis of sugar phosphates in plants by ion chromatography on a titanium dioxide column with pulsed amperometric detection.

    PubMed

    Sekiguchi, Yoko; Mitsuhashi, Naoto; Inoue, Yoshinori; Yagisawa, Hitoshi; Mimura, Tetsuro

    2004-06-11

    This paper describes the development of a practical method for the analysis of sugar phosphates from the model higher plant Arabidopsis thaliana by high-performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD). The extraction method of sugar phosphates from higher plants was first optimized for HPAEC-PAD analysis. In order to improve the resolution in HPAEC-PAD, a column packed with titanium dioxide resin was used. The titanium dioxide column was used as a trap-column for sugar phosphates and nucleotides, for the removal of sample matrices. Sample pretreatment was achieved in-line and automatically using a six-port valve placed after the injection valve.

  14. A simple procedure for the preparation of fritless columns by entrapping conventional high performance liquid chromatography sorbents.

    PubMed

    Chirica, G S; Remcho, V T

    2000-09-01

    A rapid and direct method for immobilizing conventional high performance liquid chromatography (HPLC) packing material inside fritless capillaries has been developed. Due to the simple composition of the entrapment matrix (tetraethoxysilane, alkyltriethoxysilane, ethanol and water), straightforward manufacturing procedure and modest equipment requirement, the method can readily be transferred to any laboratory and easily automated. The entrapment procedure has minimal influence on the structure and chromatographic properties of the original reverse-phase sorbent. Various immobilization solutions have been tested, and a comparison between columns entrapped with different immobilization mixtures and conventional packed capillaries is presented. High efficiency separations were obtained using tert-butyl-triethoxysilane entrapped columns in both capillary electrochromatography (reduced plate heights of 1.1-1.4 were measured) and microliquid chromatography (reduced plate heights of 2.2-2.6 were observed) formats. Elimination of frits, stabilization of the packed bed and on-the-fly customization of column length render mechanically robust columns that are remarkably stable over time, from which manufacturing imperfections can be removed easily.

  15. Fingerprinting of traditional Chinese medicines on the C18-Diol mixed-mode column in online or offline two-dimensional liquid chromatography on the single column modes.

    PubMed

    Wang, Qing; Tong, Ling; Yao, Lin; Zhang, Peng; Xu, Li

    2016-06-05

    In the present study, a mixed-mode stationary phase, C18-Diol, was applied for fingerprint analysis of traditional Chinese medicines. Hydrophobic, hydrogen bonding and electrostatic interactions were demonstrated to contribute the retention separately or jointly, which endowed the C18-Diol stationary phase with distinct selectivity compared to the bare C18 one. The separation of total alkaloids extracted from Fritillaria hupehensis was compared on the C18-Diol and conventional C18 column with the greater resolving power and better symmetry responses on the former one. Besides, a novel two-dimensional liquid chromatography on the single column (2D-LC-1C) was realized on C18-Diol with the offline mode for the alcohol extract of Fritillaria hupehensis and online mode for Ligusticum chuanxiong Hort. The early co-eluted extracted components with great polarity on the first dimension were reinjected on the same column and well separated on the second dimension. The results exhibited that the two complementary RPLC and HILIC modes on C18-Diol stationary phase enhanced the separation capacity and revealed more abundant chemical information of the sample, which was a powerful tool in analyzing complex herbal medicines.

  16. Detection and identification of heme c-modified peptides by histidine affinity chromatography, high-performance liquid chromatography-mass spectrometry, and database searching.

    PubMed

    Merkley, Eric D; Anderson, Brian J; Park, Jea; Belchik, Sara M; Shi, Liang; Monroe, Matthew E; Smith, Richard D; Lipton, Mary S

    2012-12-07

    Multiheme c-type cytochromes (proteins with covalently attached heme c moieties) play important roles in extracellular metal respiration in dissimilatory metal-reducing bacteria. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) characterization of c-type cytochromes is hindered by the presence of multiple heme groups, since the heme c modified peptides are typically not observed or, if observed, not identified. Using a recently reported histidine affinity chromatography (HAC) procedure, we enriched heme c tryptic peptides from purified bovine heart cytochrome c, two bacterial decaheme cytochromes, and subjected these samples to LC-MS/MS analysis. Enriched bovine cytochrome c samples yielded 3- to 6-fold more confident peptide-spectrum matches to heme c containing peptides than unenriched digests. In unenriched digests of the decaheme cytochrome MtoA from Sideroxydans lithotrophicus ES-1, heme c peptides for 4 of the 10 expected sites were observed by LC-MS/MS; following HAC fractionation, peptides covering 9 out of 10 sites were obtained. Heme c peptide spiked into E. coli lysates at mass ratios as low as 1×10(-4) was detected with good signal-to-noise after HAC and LC-MS/MS analysis. In addition to HAC, we have developed a proteomics database search strategy that takes into account the unique physicochemical properties of heme c peptides. The results suggest that accounting for the double thioether link between heme c and peptide, and the use of the labile heme fragment as a reporter ion, can improve database searching results. The combination of affinity chromatography and heme-specific informatics yielded increases in the number of peptide-spectrum matches of 20-100-fold for bovine cytochrome c.

  17. Detection and Identification of Heme c-Modified Peptides by Histidine Affinity Chromatography, High-Performance Liquid Chromatography-Mass Spectrometry, and Database Searching

    SciTech Connect

    Merkley, Eric D.; Anderson, Brian J.; Park, Jea H.; Belchik, Sara M.; Shi, Liang; Monroe, Matthew E.; Smith, Richard D.; Lipton, Mary S.

    2012-12-07

    Multiheme c-type cytochromes (proteins with covalently attached heme c moieties) play important roles in extracellular metal respiration in dissimilatory metal-reducing bacteria. Liquid chromatography-tandem mass spectrometry-(LC-MS/MS) characterization of c-type cytochromes is hindered by the presence of multiple heme groups, since the heme c modified peptides are typically not observed, or if observed, not identified. Using a recently reported histidine affinity chromatography (HAC) procedure, we enriched heme c tryptic peptides from purified bovine heart cytochrome c, a bacterial decaheme cytochrome, and subjected these samples to LC-MS/MS analysis. Enriched bovine cytochrome c samples yielded three- to six-fold more confident peptide-spectrum matches to heme-c containing peptides than unenriched digests. In unenriched digests of the decaheme cytochrome MtoA from Sideroxydans lithotrophicus ES-1, heme c peptides for four of the ten expected sites were observed by LC-MS/MS; following HAC fractionation, peptides covering nine out of ten sites were obtained. Heme c peptide spiked into E. coli lysates at mass ratios as low as 10-4 was detected with good signal-to-noise after HAC and LC-MS/MS analysis. In addition to HAC, we have developed a proteomics database search strategy that takes into account the unique physicochemical properties of heme c peptides. The results suggest that accounting for the double thioether link between heme c and peptide, and the use of the labile heme fragment as a reporter ion, can improve database searching results. The combination of affinity chromatography and heme-specific informatics yielded increases in the number of peptide-spectrum matches of 20-100-fold for bovine cytochrome c.

  18. Characterization of the human submandibular/sublingual saliva glycoproteome using lectin affinity chromatography coupled to multidimensional protein identification technology.

    PubMed

    Gonzalez-Begne, Mireya; Lu, Bingwen; Liao, Lujian; Xu, Tao; Bedi, Gurrinder; Melvin, James E; Yates, John R

    2011-11-04

    In-depth analysis of the salivary proteome is fundamental to understanding the functions of salivary proteins in the oral cavity and to reveal disease biomarkers involved in different pathophysiological conditions, with the ultimate goal of improving patient diagnosis and prognosis. Submandibular and sublingual glands contribute saliva rich in glycoproteins to the total saliva output, making them valuable sources for glycoproteomic analysis. Lectin-affinity chromatography coupled to mass spectrometry-based shotgun proteomics was used to explore the submandibular/sublingual (SM/SL) saliva glycoproteome. A total of 262 N- and O-linked glycoproteins were identified by multidimensional protein identification technology (MudPIT). Only 38 were previously described in SM and SL salivas from the human salivary N-linked glycoproteome, while 224 were unique. Further comparison analysis with SM/SL saliva of the human saliva proteome, revealed 125 glycoproteins not formerly reported in this secretion. KEGG pathway analyses demonstrated that many of these glycoproteins are involved in processes such as complement and coagulation cascades, cell communication, glycosphingolipid biosynthesis neo-lactoseries, O-glycan biosynthesis, glycan structures-biosynthesis 2, starch and sucrose metabolism, peptidoglycan biosynthesis or others pathways. In summary, lectin-affinity chromatography coupled to MudPIT mass spectrometry identified many novel glycoproteins in SM/SL saliva. These new additions to the salivary proteome may prove to be a critical step for providing reliable biomarkers in the diagnosis of a myriad of oral and systemic diseases.

  19. Enrichment and Analysis of Nonenzymatically Glycated Peptides: Boronate Affinity Chromatography Coupled with Electron-Transfer Dissociation Mass Spectrometry

    SciTech Connect

    Zhang, Qibin; Tang, Ning; Brock, Jonathan W.; Mottaz, Heather M.; Ames, Jennifer M.; Baynes, John; Smith, Richard D.; Metz, Thomas O.

    2007-06-01

    Non-enzymatic glycation of peptides and proteins by D-glucose has important implications in the pathogenesis of diabetes mellitus, particularly in the development of diabetic complications. However, no effective high-throughput methods exist for identifying proteins containing this low abundance post-translational modification in bottom-up proteomic studies. In this report, phenylboronate affinity chromatography was used in a two-step enrichment scheme to selectively isolate first glycated proteins and then glycated, tryptic peptides from human serum glycated in vitro. Enriched peptides were subsequently analyzed by alternating electron transfer dissociation (ETD) and collision induced dissociation (CID) tandem mass spectrometry. It was observed that ETD fragmentation mode resulted in a significantly higher number of glycated peptide identifications (87.6% of all identified peptides) versus CID mode (17.0% of all identified peptides), when utilizing dual glycation enrichment on both the protein and peptide level. This study illustrates that phenylboronate affinity chromatography coupled with LC-MS/MS with ETD as the fragmentation mode is an efficient approach for analyses of glycated proteins and can have broad applications in studies of diabetes mellitus.

  20. Separation and analysis of cis-diol-containing compounds by boronate affinity-assisted micellar electrokinetic chromatography.

    PubMed

    Wang, Heye; Lü, Chenchen; Li, Hengye; Chen, Yang; Zhou, Min; Ouyang, Jian; Liu, Zhen

    2013-10-01

    Cis-diol-containing compounds (CDCCs) are usually highly hydrophilic compounds and are therefore difficult to separate by conventional reversed-phase-based micellar electrokinetic chromatography (MEKC) due to poor selectivity. Here, we report a new method, called boronate affinity-assisted micellar electrokinetic chromatography (BAA-MEKC), to solve this issue. A boronic acid with a hydrophobic alkyl chain was added to the background electrolyte, which acted as a modifier to adjust the selectivity. CDCCs can covalently react with the boronic acid to form negatively charged surfactant-like complexes, which can partition into micelles formed with a cationic surfactant. Thus, CDCCs can be separated according to the differential partition constants of their boronic acid complexes between the micellar phase and the surrounding aqueous phase. To verify this method, eight nucleosides were employed as the test compounds and their separation confirmed that the combination of boronate affinity interaction with MEKC can effectively enhance the separation of CDCCs. The effects of experimental conditions on the separation were investigated. Finally, the BAA-MEKC method was applied to the separation and analysis of nucleosides extracted from human urine. BAA-MEKC exhibited better selectivity and improved separation as compared with conventional MEKC and CZE. Successful quantitative analysis of urinary nucleosides by BAA-MEKC was demonstrated.

  1. Quantitative Phosphoproteome Analysis of Lysophosphatidic Acid Induced Chemotaxis applying Dual-step ¹⁸O Labeling Coupled with Immobilized Metal-ion Affinity Chromatography

    SciTech Connect

    Ding, Shi-Jian; Wang, Yingchun; Jacobs, Jon M.; Qian, Weijun; Yang, Feng; Tolmachev, Aleksey V.; Du, Xiuxia; Wang, Wei; Moore, Ronald J.; Monroe, Matthew E.; Purvine, Samuel O.; Waters, Katrina M.; Heibeck, Tyler H.; Adkins, Joshua N.; Camp, David G.; Klemke, Richard L.; Smith, Richard D.

    2008-10-01

    Reversible protein phosphorylation is a central cellular regulatory mechanism in modulating protein activity and propagating signals within cellular pathways and networks. Development of more effective methods for the simultaneous identification of phosphorylation sites and quantification of temporal changes in protein phosphorylation could provide important insights into molecular signaling mechanisms in a variety of different cellular processes. Here we present an integrated quantitative phosphoproteomics approach and its applications for comparative analysis of Cos-7 cells in response to lysophosphatidic acid (LPA) gradient stimulation. The approach combines trypsin-catalyzed 16O/18O labeling plus 16O/18O-methanol esterification labeling for quantitation, a macro- Immobilized Metal-ion Affinity Chromatography trap for phosphopeptide enrichment, and a monolithic capillary column with integrated electrospray emitter. LC separation and MS/MS is followed by neutral loss-dependent MS/MS/MS for phosphopeptide identification using a linear ion trap (LTQ)-FT mass spectrometer and complementary searching algorithms for interpreting MS/MS spectra. Protein phosphorylation involved in various signaling pathways of cell migration were identified and quantified, such as mitogen-activated protein kinase 1, dual-specificity mitogen-activated protein kinase kinase 2, and dual-specificity tyrosine-phosphorylation regulated kinase 1b, and a number of Rho GTPase-activating proteins. These results demonstrate the efficiency of this quantitative phosphoproteomics approach and its application for rapid discovery of phosphorylation events associated with gradient sensing and cell chemotaxis.

  2. Separation and quantitation of hepatoma-associated gamma-glutamyltransferase by affinity chromatography with Affi-Gel blue and Con A-Sepharose.

    PubMed

    Izumi, M; Taketa, K

    1983-01-01

    Isozymes of serum gamma-glutamyltransferase (GGT) in patients with hepatocellular carcinoma (HCC) and other liver diseases were separated into two groups by double-affinity column chromatography with Affi-Gel blue and Con A-Sepharose, one recovered in the unbound fraction and the other in the bound fraction. Upon electrophoresis with polyacrylamide gradient gel slabs, the unbound fraction gave a GGTI1 band and a faint II1 band and the bound fraction gave a GGT I band and faint bands of GGT I", II' and X, when the original serum contained hepatoma-associated GGT (I1, I" and II') and high-molecular-weight lipid-protein complex, GGT(X). GGT I was present in all cases as a common isozyme. Other lipoprotein-associated GGT isozymes, III-IX, were removed by passing through Affi-Gel blue. GGT activities of unbound fraction in patients with HCC were generally higher than those in patients with non-HCC liver diseases, although the difference was not significant. When the percent of GGT activity of unbound (unbound + bound) was taken, 54% of patients with HCC had a ratio greater than 22%, whereas none of the healthy subjects or patients with other liver diseases gave values greater than this. The present technique may prove to be a useful clinical test for the diagnosis of HCC.

  3. Production of capsular polysaccharide of Streptococcus pneumoniae type 14 and its purification by affinity chromatography.

    PubMed

    Suárez, N; Fraguas, L F; Texeira, E; Massaldi, H; Batista-Viera, F; Ferreira, F

    2001-02-01

    We describe a rapid and efficient method for producing the capsular polysaccharide of Streptococcus pneumoniae by fermentation on tryptic soy broth and purification of this compound by using immobilized soybean lectin as an affinity adsorbent. In principle, the same strategy can be used to produce purified capsular polysaccharides from other streptococcal serotypes by selecting the appropriate lectin adsorbents.

  4. Production of Capsular Polysaccharide of Streptococcus pneumoniae Type 14 and Its Purification by Affinity Chromatography

    PubMed Central

    Suárez, Norma; Fraguas, Laura Franco; Texeira, Esther; Massaldi, Hugo; Batista-Viera, Francisco; Ferreira, Fernando

    2001-01-01

    We describe a rapid and efficient method for producing the capsular polysaccharide of Streptococcus pneumoniae by fermentation on tryptic soy broth and purification of this compound by using immobilized soybean lectin as an affinity adsorbent. In principle, the same strategy can be used to produce purified capsular polysaccharides from other streptococcal serotypes by selecting the appropriate lectin adsorbents. PMID:11157270

  5. Exogenous factors contributing to column bed heterogeneity: Part 1: Consequences of 'air' injections in liquid chromatography.

    PubMed

    Samuelsson, Jörgen; Fornstedt, Torgny; Shalliker, Andrew

    2015-08-07

    It has been shown that not only the packing homogeneity, but also factors external to the column bed, such as, frits and distributors can have important effects on the column performance. This current communication is the first in a series focusing on the impact of exogenous factors on the column bed heterogeneity. This study is based on several observations by us and others that chromatographic runs often, for technical reasons, include more or less portions of air in the injections. It is therefore extremely important to find out the impact of air on the column performance, the reliability of the results derived from analyses where air was injected, and the effect on the column homogeneity. We used a photographic approach for visualising the air transport phenomena, and found that the air transport through the column is comprised of many different types of transport phenomena, such as laminal flow, viscous fingering like flows, channels and bulbs, and pulsations. More particularly, the air clouds within the column definitely interact in the adsorption, i.e. mobile phase adsorbed to the column surface is displaced. In addition, irrespective of the type of air transport phenomena, the air does not penetrate the column homogeneously. This process is strongly flow dependent. In this work we study air transport both in an analytical scale and a semi-prep column.

  6. Simple column-switching ion chromatography method for determining eight monosaccharides and oligosaccharides in honeydew and nectar.

    PubMed

    Ni, Chengzhu; Zhu, Binhe; Wang, Nani; Wang, Muhua; Chen, Suqing; Zhang, Jiajie; Zhu, Yan

    2016-03-01

    Honeydew is excreted by aphids as a sweet waste and nectar is floral honey. Honeydew and nectar are complicated samples which consist of various sugars and amino acids. In this work, a simple ion chromatography with column-switching method was developed for the simultaneous analysis of 8 monosaccharides and oligosaccharides in honeydew and nectar. A reversed-phase column was used as a pretreatment column to eliminate organics on-line and sugars were eluted from a collection loop to analytical column by using column-switching technique. This method showed good linearity (r⩾0.9994) and afforded low limits of detection ranging from 1.55 to 10.17μgL(-1) for all the analytes. Recoveries ranged from 95% to 105% and repeatability results were acceptable with relative standard deviation of less than 3.21% (n=6). This method was successfully applied to quantification of these sugars in honeydew and nectar. These results showed honeydew had much more oligosaccharides than nectar.

  7. Multidimensional high-performance liquid chromatography on Pinkerton ISRP and RP18 columns: direct serum injection to quantify creatinine.

    PubMed

    Puhlmann, A; Dülffer, T; Kobold, U

    1992-10-02

    A two-dimensional high-performance liquid chromatographic method for the determination of creatinine with direct serum injection without sample pretreatment has been developed. The column-switching technique allowed a switch from columns packed with internal surface reversed-phase (ISRP) material to columns of almost any other material, even if the eluents necessary in a particular case do not appear to be directly compatible. A Pinkerton ISRP column, which stands out because of its very good stability when loaded with undiluted serum samples, was used as precolumn. The creatinine-containing fraction was switched to a reversed-phase Shandon RP18 column and was focused there by alteration of the eluent from pH 6.5 to phosphoric acid-ion-pair reagent. The separation occurs via a pH gradient, with ultraviolet detection at 234 nm. This method stands out particularly for its good long-term stability, simple sample handling without pretreatment, high selectivity, a broad linearity (0.3-30 mg/dl creatinine), good reproducibility (inter-assay coefficient of variation less than 3%) and high recovery (97-100%) relative to values obtained with gas chromatography-mass spectrometry.

  8. Tuning preparation conditions towards optimized separation performance of thermally polymerized organo-silica monolithic columns in capillary liquid chromatography.

    PubMed

    Gharbharan, Deepa; Britsch, Denae; Soto, Gabriela; Weed, Anna-Marie Karen; Svec, Frantisek; Zajickova, Zuzana

    2015-08-21

    Tuning of preparation conditions, such as variations in the amount of a porogen, concentration of an aqueous acid catalyst, and adjustment in polymerization temperature and time, towards optimized chromatographic performance of thermally polymerized monolithic capillaries prepared from 3-(methacryloyloxy)propyltrimethoxysilane has been carried out. Performance of capillary columns in reversed-phase liquid chromatography was assessed utilizing various sets of solutes. Results describing hydrophobicity, steric selectivity, and extent of hydrogen bonding enabled comparison of performance of hybrid monolithic columns prepared under thermal (TSG) and photopolymerized (PSG) conditions. Reduced amounts of porogen in the polymerization mixture, and prolonged reaction times were necessary for the preparation of monolithic columns with enhanced retention and column efficiency that reached to 111,000 plates/m for alkylbenzenes with shorter alkyl chains. Both increased concentration of catalyst and higher temperature resulted in faster polymerization but inevitably in insufficient time for pore formation. Thermally polymerized monoliths produced surfaces, which were slightly more hydrophobic (a methylene selectivity of 1.28±0.002 TSG vs 1.20±0.002 PSG), with reduced number of residual silanols (a caffeine/phenol selectivity of 0.13±0.001 TSG vs 0.17±0.003 PSG). However, steric selectivity of 1.70±0.01 was the same for both types of columns. The batch-to-batch repeatability was better using thermal initiation compared to monolithic columns prepared under photopolymerized conditions. RSD for retention factor of benzene was 3.7% for TSG capillaries (n=42) vs. 6.6% for PSG capillaries (n=18). A similar trend was observed for columns prepared within the same batch.

  9. Robust design of adenovirus purification by two-column, simulated moving-bed, size-exclusion chromatography.

    PubMed

    Nestola, Piergiuseppe; Silva, Ricardo J S; Peixoto, Cristina; Alves, Paula M; Carrondo, Manuel J T; Mota, José P B

    2015-11-10

    A simple, yet efficient, two-column simulated moving-bed (2CSMB) process for purifying adenovirus serotype 5 (Ad5) by size-exclusion chromatography (SEC) is presented and validated experimentally, and a general procedure for its robust design under parameter uncertainty is described. The pilot-scale run yielded a virus recovery of 86 percent and DNA and HCP clearances of 90 and 89 percent, respectively, without any fine tuning of the operating parameters. This performance compares very favorably against that of single-column batch chromatography for the same volume of size-exclusion resin. To improve the robustness of the 2CSMB-SEC process the best set of operating parameters is selected only among candidate solutions that are robust feasible, that is, remain feasible for all parameter perturbations within their uncertainty intervals. This robust approach to optimal design replaces the nominal problem by a worst case problem. Computational tractability is ensured by formulating the robust design problem with only the vertices of the uncertainty region that have the worst effect on the product purity and recovery. The robust design is exemplified on the case where the column volume and interparticle porosity are subject to uncertainty. As expected, to increase the robustness of the 2CSMB-SEC process it is necessary to reduce its productivity and increase its solvent consumption. Nevertheless, the design solution given by our robust approach is the least detrimental of all feasible operating conditions for the 2CSMB-SEC process.

  10. Isolation and purification of diastereoisomeric flavonolignans from silymarin by binary-column recycling preparative high-performance liquid chromatography.

    PubMed

    Zhao, Weiquan; Yang, Guang; Zhong, Fanyi; Yang, Nan; Zhao, Xin; Qi, Yunpeng; Fan, Guorong

    2014-09-01

    Silymarin extracted from Silybum marianum (L.) Gaertn consists of a large number of flavonolignans, of which diastereoisomeric flavonolignans including silybin A and silybin B, and isosilybin A and isosilybin B are the main bioactive components, whose preparation from the crude extracts is still a difficult task. In this work, binary-column recycling preparative high-performance liquid chromatography systems without sample loop trapping, where two columns were switched alternately via one or two six-port switching valves, were established and successfully applied to the isolation and purification of the four diastereoisomeric flavonolignans from silymarin. The proposed system showed significant advantages over conventional preparative high-performance liquid chromatography with a single column in increasing efficiency and reducing the cost. To obtain the same amounts of products, the proposed system spends only one tenth of the time that the conventional system spends, and needs only one eleventh of the solvent that the conventional system consumes. Using the proposed system, the four diastereoisomers were successfully isolated from silymarin with purities over 98%.

  11. Hydrophilic interaction chromatography of seized drugs and related compounds with sub 2 μm particle columns.

    PubMed

    Lurie, Ira S; Li, Li; Toske, Steven G

    2011-12-30

    The use of hydrophilic interaction chromatography (HILIC) with sub 2 μm particle columns for the analysis of drugs and related compounds of forensic interest is described. This technique uses a high organic/low aqueous buffered mobile phase with a polar stationary phase, and is excellent for the separation of many of the charged solutes that are found in forensic drug exhibits. In this study, HILIC is investigated for 11 solutes of forensic interest, including weak bases, weak acids, and a neutral solute. In addition, for columns containing either ethylene bridged hybrid particles with or without an amide bonded phase, the effects of acetonitrile concentration, buffer type, buffer concentration, linear velocity, and sample concentration were studied. Based on these studies, HILIC with sub 2 μm particle columns can offer highly efficient, selective, and rapid isocratic separations of drugs and related compounds of forensic interest, with excellent peak shapes and low back pressures. This is in contrast to reverse phase chromatography (RPLC), where gradient elution is usually required, which can result in extensive overlap between acidic, neutral, and basic solutes. In addition, since HILIC exhibits a much greater loading capacity than RPLC, it could be a preferred technique for drug profiling. Furthermore, because high organic content mobile phases are highly amenable to mass spectrometric detection, the use of HILIC with tandem mass spectrometric detection for the analysis of seized drugs is described.

  12. Monolithic columns with organic sorbent based on poly-1-vinylimidazole for high performance liquid chromatography

    NASA Astrophysics Data System (ADS)

    Patrushev, Y. V.; Sidelnikov, V. N.; Yudina, Y. S.

    2017-03-01

    Monolithic chromatographic columns for HPLC with sorbent based on 1-vinylimidazole are prepared. It is shown that changing the 1-vinylimidazole content in the initial solution allows us to change the polarity of columns. An example of aromatic hydrocarbons separation is presented.

  13. Planar gas chromatography column on glass plate with nanodispersed silica as the stationary phase

    NASA Astrophysics Data System (ADS)

    Platonov, I. A.; Platonov, V. I.; Pavelyev, V. S.; Agafonov, A. N.

    2016-04-01

    The paper presents the GC column in the plane of the glass plate with the adsorption layer nanodispersed silica. Created gas chromatographic column allows to separate a mixture of five alkanes from pentane to nonane in isothermal (90 ° C) mode less than one minute.

  14. Effects of a malfunctional column on conventional and FeedCol-simulated moving bed chromatography performance.

    PubMed

    Song, Ji-Yeon; Oh, Donghoon; Lee, Chang-Ha

    2015-07-17

    The effects of a malfunctional column on the performance of a simulated moving bed (SMB) process were studied experimentally and theoretically. The experimental results of conventional four-zone SMB (2-2-2-2 configuration) and FeedCol operation (2-2-2-2 configuration with one feed column) with one malfunctional column were compared with simulation results of the corresponding SMB processes with a normal column configuration. The malfunctional column in SMB processes significantly deteriorated raffinate purity. However, the extract purity was equivalent or slightly improved compared with the corresponding normal SMB operation because the complete separation zone of the malfunctional column moved to a lower flow rate range in zones II and III. With the malfunctional column configuration, FeedCol operation gave better experimental performance (up to 7%) than conventional SMB operation because controlling product purity with FeedCol operation was more flexible through the use of two additional operating variables, injection time and injection length. Thus, compared with conventional SMB separation, extract with equivalent or slightly better purity could be produced from FeedCol operation even with a malfunctional column, while minimizing the decrease in raffinate purity (less than 2%).

  15. Quasi-adiabatic vacuum-based column housing for very high-pressure liquid chromatography.

    PubMed

    Gritti, Fabrice; Gilar, Martin; Jarrell, Joseph A

    2016-07-22

    A prototype vacuum-based (10(-6)Torr) column housing was built to thermally isolate the chromatographic column from the external air environment. The heat transfer mechanism is solely controlled by surface radiation, which was minimized by wrapping the column with low-emissivity aluminum tape. The adiabaticity of the column housing was quantitatively assessed from the measurement of the operational pressure and fluid temperature at the outlet of a 2.1mm×100mm column (sub-2 μm particles). The pressure drop along the column was raised up to 1kbar. The enthalpy balance of the eluent (water, acetonitrile, and one water/acetonitrile mixture, 70/30, v/v) showed that less than 1% of the viscous heat generated by friction of the fluid against the packed bed was lost to the external air environment. Such a vacuum-based column oven minimizes the amplitude of the radial temperature gradients across the column diameter and maximizes its resolving power.

  16. Investigation of a new core-shell particle column for ion-pair reversed-phase liquid chromatography analysis of oligonucleotides.

    PubMed

    Biba, Mirlinda; Welch, Christopher J; Foley, Joe P

    2014-08-05

    A new core-shell particle column showed excellent performance and durability for separation of short (∼21-mer) ribonucleic acid (RNA) oligonucleotides by ion-pair reversed-phase liquid chromatography (IP-RPLC). Previously investigated core-shell C18 columns showed excellent peak shapes and separations of closely eluting impurities by IP-RPLC. However, these columns showed only modest long-term stability at the neutral pH and elevated column temperatures of ≥60°C, typically used for IP-RPLC analysis of oligonucleotides. The newly introduced SunShell C18 column provided separations comparable to the previously evaluated core-shell columns, but with significantly improved long-term column stability when operated at neutral pH and elevated column temperature.

  17. [Affinity chromatography and proteomic screening as the effective method for S100A4 new protein targets discovery].

    PubMed

    Koshelev, Iu A

    2014-01-01

    Affinity chromatography followed by a selective binding proteins identification can be using as effective method for a biological impotent interactions discovery. The molecular structure and their surface charge as and conformational regulation possibilities, which change their surface hydrophobic properties, all they should to taken in account during method optimization process. With the same' method we had identify some new S100A4 target proteins such as cytoskeleton proteins Sept2, Sept7, Sept11 and this interaction would can to highlight as S100A4 would regulate cell motility. Even we had identify the transcription cofactor Ddx5 and through such complex formation a S100A4 protein would can to regulate E-cadherin, p21 Waf1/Cip1), Bnip3 gene expression. The same protocol can be using for a target proteins search with another S100 protein family members, because their molecules demonstrate a high homology level in amino aside sequences and 3D structures.

  18. Separation of Binding Protein of Celangulin V from the Midgut of Mythimna separata Walker by Affinity Chromatography

    PubMed Central

    Lu, Lina; Qi, Zhijun; Zhang, Jiwen; Wu, Wenjun

    2015-01-01

    Celangulin V, an insecticidal compound isolated from the root bark of Chinese bittersweet, can affect the digestive system of insects. However, the mechanism of how Celangulin V induces a series of symptoms is still unknown. In this study, affinity chromatography was conducted through coupling of Celangulin V-6-aminoacetic acid ester to the CNBr-activated Sepharose 4B. SDS-PAGE was used to analyze the collected fraction eluted by Celangulin V. Eight binding proteins (Zinc finger protein, Thioredoxin peroxidase (TPx), Glyceraldehyde 3-phosphate dehydrogenase (GAPDH), SUMO E3 ligase RanBP2, Transmembrane protein 1, Actin, APN and V-ATPase) were obtained and identified by LC/Q-TOF-MS from the midgut of Mythimna separata larvae. The potential of these proteins to serve as target proteins involved in the insecticidal activity of Celangulin V is discussed. PMID:25996604

  19. Evaluation of immobilized metal affinity chromatography kits for the purification of histidine-tagged recombinant CagA protein.

    PubMed

    Karakus, Cebrail; Uslu, Merve; Yazici, Duygu; Salih, Barik A

    2016-05-15

    Immobilized metal affinity chromatography (IMAC) technique is used for fast and reliable purification of histidine(His)-tagged recombinant proteins. The technique provides purification under native and denaturing conditions. The aim of this study is to evaluate three commercially available IMAC kits (Thermo Scientific, GE Healthcare and Qiagen) for the purification of a 6xHis-tagged recombinant CagA (cytotoxin-associated gene A) protein from IPTG-induced Escherichia coli BL21(DE3) culture. The kits were tested according to the manufacturer instructions and the protein was purified with only GE Healthcare and Qiagen kits under denaturing conditions. 1% (w/v) SDS was used as denaturing agent in PBS instead of extraction reagent of Thermo Scientific kit to lyse bacterial cells from 100ml culture. The 6xHis-tagged recombinant protein was purified by the three kits equally.

  20. Overloading study of basic compounds with a positively charged C18 column in liquid chromatography.

    PubMed

    Wang, Chaoran; Guo, Zhimou; Long, Zhen; Zhang, Xiuli; Liang, Xinmiao

    2013-03-15

    While tailing and overloading of basic compounds remain problematic on most RP columns, a new kind of positively charged RP column named XCharge C18 was found to be superior good for the separation of alkaloids in our practical use. In this work, the surface charge property of the XCharge C18 column was evaluated by the retention of NO(3)(-) under different pH values and buffer concentrations. A considerable and pH-dependent positive charge was confirmed on the column. Then overloading behaviors of bases were systematically studied using amitriptyline as a basic probe. Good peak shapes (Tf<1.5) and extra high loadability with a C(0.5) of about 30,000 mg/L were observed on the column, with commonly used 0.1% formic acid as mobile phase additive. However, increasing the ionic strength of buffer with phosphates led to tailing peaks at high sample amount and sharp decline in loadability (C(0.5) of 2000-3000 mg/L), although it brought higher column efficiency at low sample amount. Higher pH also induced worse performance and lower loadability. The overall results demonstrated the importance of an appropriate level of ionic repulsion for the XCharge C18 column to achieve the good performance for bases, which could be explained by the multiple-site adsorption theory as ionic repulsion would shield the solute from occupying high-energy sites deeper in C18 layer.

  1. Two-column sequential injection chromatography for fast isocratic separation of two analytes of greatly differing chemical properties.

    PubMed

    Šatínský, Dalibor; Chocholouš, Petr; Válová, Olga; Hanusová, Lucia; Solich, Petr

    2013-09-30

    This paper deals with a novel approach to separate two analytes with different chemical properties and different lipophilicity. The newly described methodology is based on the two column system that was used for isocratic separation of two analytes with very different lipophilicity-dexamethasone and cinchocaine. Simultaneous separation of model compounds cinchocaine and dexamethasone was carried under the following conditions in two-column sequential injection chromatography system (2-C SIC). A 25×4.6 mm C-18 monolithic column was used in the first dimension for retention and separation of dexamethasone with mobile phase acetonitrile:water 30:70 (v/v), flow rate 0.9 mL min(-1) and consumption of 1.7 mL. A 10×4.6 mm C-18 monolithic column with 5×4.6 mm C-18 precolumn was used in the second dimension for retention and separation of cinchocaine using mobile phase acetonitrile:water 60:40 (v/v), flow rate 0.9 mL min(-1) and consumption 1.5 mL. Whole analysis time including both mobile phase's aspirations and both column separations was performed in less than 4 min. The method was fully validated and used for determination of cinchocaine and dexamethasone in pharmaceutical otic drops. The developed 2-C SIC method was compared with HPLC method under the isocratic conditions of separation on monolithic column (25×4.6 mm C-18). Spectrophotometric detection of both compounds was performed at wavelength 240 nm. System repeatability and method precision were found in the range (0.39-3.12%) for both compounds. Linearity of determination was evaluated in the range 50-500 μg mL(-1) and coefficients of determination were found to be r(2)=0.99912 for dexamethasone and r(2)=0.99969 for cinchocaine.

  2. Displacement chromatography of proteins using a retained pH front in a hydrophobic charge induction chromatography column.

    PubMed

    Pinto, N D S; Frey, Douglas D

    2015-03-27

    The chromatographic separation of two proteins into a displacement train of two adjoined rectangular bands was accomplished using a novel method for hydrophobic charge induction chromatography (HCIC) which employs a self-sharpening pH front as the displacer. This method exploits the fact that protein elution in HCIC is promoted by a pH change, but is relatively independent of salt effects, so that a retained pH front can be used in place of a traditional displacer in displacement chromatography. The retained pH front was produced using the two adsorbed buffering species tricine and acetic acid. The separation of lysozyme and α-chymotrypsinogen A into adjoined, rectangular bands was accomplished with overall recoveries based on the total mass injected greater than 90 and 70%, respectively. The addition of urea to the buffer system increased the sharpness of the pH front by 36% while the yields of lysozyme and α-chymotrypsinogen A based on the total mass eluted increased from 76% to 99% and from 37% to 85%, respectively, when the purities of both proteins in their product fractions were fixed at 85%. The results demonstrate that the method developed in this study is a useful variant of HCIC and is also a useful alternative to other displacement chromatography methods.

  3. Rapid determination of Papaver somniferum alkaloids in process streams using monolithic column high-performance liquid chromatography with chemiluminescence detection.

    PubMed

    Costin, Jason W; Lewis, Simon W; Purcell, Stuart D; Waddell, Lucy R; Francis, Paul S; Barnett, Neil W

    2007-07-30

    We have combined high-performance liquid chromatography (HPLC) separations using a monolithic column with acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence detection in a rapid and highly sensitive method to monitor the process of extracting opiate alkaloids from Papaver somniferum. Due to the high flow rates allowed with the monolithic column and the inherent selectivity of the chemiluminescence reactions, the four predominant alkaloids--morphine, codeine, oripavine and thebaine--were determined in less than 2 min. The results obtained with numerous process samples compared favourable with those of the standard HPLC methodology. Limits of detection were 1x10(-10) M, 5x10(-10) M, 5x10(-10) M and 1x10(-9) M, for morphine, codeine, oripavine and thebaine, respectively.

  4. Standardized test mixture for the characterization of comprehensive two-dimensional gas chromatography columns: the Phillips mix.

    PubMed

    Dimandja, Jean-Marie D; Clouden, Garrick C; Colón, Ivelisse; Focant, Jean-François; Cabey, Whitney V; Parry, Ritchard C

    2003-11-26

    A novel column characterization test mixture is developed for use in comprehensive two-dimensional gas chromatography (GC x GC). This mixture has been named the "Phillips mix" in honor of the late professor John B. Phillips, the father of GC x GC. The mixture comprises a series of homologous compounds from structural groups that cover a volatility and polarity range that is similar to the Grob mix, and includes saturated hydrocarbons (alkanes), unsaturated hydrocarbons (alkenes and alkynes), carbonyls (ketones and aldehydes), primary alcohols, fatty acid methyl esters, alkyl ethers, carboxylic acids, aromatics, as well as other unique functional groups (such as amines, etc.). Similarly to the Grob mix in conventional one-dimensional GC, the Phillips mix can be used as a standardized test for performance characterization of GC x GC column sets. Unlike the Grob mix, however, the Phillips mix's most important use is as a practical guideline for column users. This paper addresses some qualitative aspects of the use of the Phillips mix through an investigation of the chromatographic fingerprints of two different GC x GC column combinations.

  5. Separation of beta-human chorionic gonadotropin and immunoglobulin G by a miniaturized size exclusion chromatography column

    NASA Astrophysics Data System (ADS)

    Yang, Yongmo; Chae, Junseok

    2009-04-01

    This report describes a miniaturized size exclusion chromatography column that effectively preseparates raw samples for medical point-of-care testing (POCT) devices. The minicolumn is constructed of polydimethylsiloxane fabricated on a glass slide. The minicolumn separates 300 ng/ml of beta-human chorionic gonadotropin (β-hCG) from an immunoglobulin G (IgG)-rich solution (100 μg/ml) in 7.7 min, with 2.23 resolution and 0.018 mm plate height. The complete analyte discrimination shows potential for the sample preparation stage of POCT devices for cancer screening, prognosis, and monitoring.

  6. The Plasma Membrane Ca(2+) ATPase: Purification by Calmodulin Affinity Chromatography, and Reconstitution of the Purified Protein.

    PubMed

    Niggli, Verena; Carafoli, Ernesto

    2016-01-01

    Plasma membrane Ca(2+) ATPases (PMCA pumps) are key regulators of cytosolic Ca(2+) in eukaryotes. They extrude Ca(2+) from the cytosol, using the energy of ATP hydrolysis and operate as Ca(2+)-H(+) exchangers. They are activated by the Ca(2+)-binding protein calmodulin, by acidic phospholipids and by other mechanisms, among them kinase-mediated phosphorylation. Isolation of the PMCA in pure and active form is essential for the analysis of its structure and function. In this chapter, the purification of the pump, as first achieved from erythrocyte plasma membranes by calmodulin-affinity chromatography, is described in detail. The reversible, high-affinity, Ca(2+)-dependent interaction of the pump with calmodulin is the basis of the procedure. Either phospholipids or glycerol have to be present in the isolation buffers to keep the pump active during the isolation procedure. After the isolation of the PMCA pump from human erythrocytes the pump was purified from other cell types, e.g., heart sarcolemma, plant microsomal fractions, and cells that express it ectopically. The reconstitution of the purified pump into phospholipid vesicles using the cholate dialysis method will also be described. It allows studies of transport mechanism and of regulation of pump activity. The purified pump can be stored in the reconstituted form for several days at 4 °C with little loss of activity, but it rapidly loses activity when stored in the detergent-solubilized form.

  7. Affinity chromatography on immobilized "biomimetic" ligands. Synthesis, immobilization and chromatographic assessment of an immunoglobulin G-binding ligand.

    PubMed

    Teng, S F; Sproule, K; Husain, A; Lowe, C R

    2000-03-31

    A synthetic bifunctional ligand (22/8) comprising a triazine scaffold substituted with 3-aminophenol (22) and 4-amino-1-naphthol (8) has been designed, synthesised, characterised and immobilized on agarose beads to create a robust, highly selective affinity adsorbent for human immunoglobulin G (IgG). Scatchard analysis of the binding isotherm for IgG on immobilized 22/8 (90 micromol 22/8/g moist weight gel) indicated an affinity constant (Ka) of 1.4 x 10(5) M(-1) and a theoretical maximum capacity of 151.9 mg IgG/g moist weight gel. The adsorbent shows similar selectivity to immobilized protein A and binds IgG from a number of species. An apparent capacity of 51.9 mg human IgG/g moist weight gel was observed under the experimental conditions selected for adsorption. Human IgG was eluted with glycine-HCl buffer with a recovery of 67-69% and a purity of 97.3-99.2%, depending on the pH value of the buffer used for elution. Preparative chromatography of IgG from human plasma showed that under the specified conditions, 94.4% of plasma IgG was adsorbed and 60% subsequently eluted with a purity of 92.5%. The immobilized ligand was able to withstand incubation in 1 M NaOH for 7 days without loss of binding capacity for IgG.

  8. Ultra sensitive affinity chromatography on avidin-functionalized PMMA microchip for low abundant post-translational modified protein enrichment.

    PubMed

    Xia, Hui; Murray, Kermit; Soper, Steven; Feng, June

    2012-02-01

    Post-translational modifications (PTM) of proteins play essential roles in cellular physiology and disease. The identification of protein substrates and detection of modification site helps understand PTM-mediated regulation in essential biological pathways and functions in various diseases. However, PTM proteins are typically present only at trace levels, making them difficult to identify in mass spectrometry based proteomics. In this paper, we report a novel and sensitive affinity chromatography on the avidin-functionalized poly(methyl methacrylate) (PMMA) microchip for enrichment of nanogram (ng) amount of PTMs. The chemical modification of poly(methyl methacrylate) (PMMA) surfaces yield avidin-terminated PMMA surfaces after UV radiation and consecutive EDC mediated coupling (amide reaction). This functionalized PMMA micro-device was developed to identify and specifically trap biotinylated PTM proteins of low abundance from complex protein mixture. Here we selected carbonylated protein as a representative PTM to illustrate the wide application of this affinity microchip for any PTMs converted into a tractable tag after derivatization. The surface topography, surface functional group mapping and elemental composition changes after each modification step of the treatment process were systematically measured qualitatively and quantitatively by atomic force microscopy, X-ray photoelectron spectroscopy and fluorescence microscopy. Quantitative study of biotinlated carbonylated protein capture recovery and elution efficiency of the device was also studied. We also envision that this subproteome enrichment micro-device can be assembled with other lab-on-a-chip components for follow-up protein analysis.

  9. Micro-fabricated packed gas chromatography column based on laser etching technology.

    PubMed

    Sun, J H; Guan, F Y; Zhu, X F; Ning, Z W; Ma, T J; Liu, J H; Deng, T

    2016-01-15

    In this work, a micro packed gas chromatograph column integrated with a micro heater was fabricated by using laser etching technology (LET) for analyzing environmental gases. LET is a powerful tool to etch deep well-shaped channels on the glass wafer, and it is the most effective way to increase depth of channels. The fabricated packed GC column with a length of over 1.6m, to our best knowledge, which is the longest so far. In addition, the fabricated column with a rectangular cross section of 1.2mm (depth) × 0.6mm (width) has a large aspect ratio of 2:1. The results show that the fabricated packed column had a large sample capacity, achieved a separation efficiency of about 5800 plates/m and eluted highly symmetrical Gaussian peaks.

  10. Direct determination of benzamides in serum by column-switching high-performance liquid chromatography.

    PubMed

    Chiba, Ryoko; Ogasawara, Ayako; Kubo, Teppei; Yamazaki, Hiroyuki; Umino, Masuo; Ishizuka, Yoichi

    2003-05-01

    A column-switching high-performance liquid chromatographic method with fluorescence detection was developed for the simultaneous determination of four benzamide-type anti-psychotic drugs: sulpiride, tiapride, sultopride and metoclopramide in human serum. In this method, a TSKgel Super-ODS column was used as an analytical column, and a TSKgel G 2000SW was prepared as a pretreatment column. Under the optimized analytical conditions, four benzamide-type anti-psychotic drugs were eluted within 18 min. The detection limits (S/N = 3) for sulpiride, tiapride, sultopride and metoclopramide are 1 ng/ml, 4 ng/ml, 2 ng/ml and 0.5 ng/ml, respectively. Finally, the method was applied to the determination of sulpiride in human serum samples obtained after a single oral dose of sulpiride.

  11. Zero-derivative boundary condition for pulsed distributed systems. [column chromatography example

    NASA Technical Reports Server (NTRS)

    Lashmet, P. K.; Woodrow, P. T.

    1975-01-01

    To permit use of experimentally determined Peclet numbers in numerical simulations of pulsed distributed flow systems such as chromatograph columns, substitution of the zero-derivative boundary condition for the infinite boundary condition used in treating data is examined. Moment analysis shows that application of the zero-derivative condition external to the column will yield equivalent numerical results for the two boundary conditions. Criteria for locating this position are provided as a function of the Peclet number.

  12. Complete temperature profiles in ultra-high-pressure liquid chromatography columns.

    PubMed

    Gritti, Fabrice; Guiochon, Georges

    2008-07-01

    The temperature profiles were calculated along and across seven packed columns (lengths 30, 50, 100, and 150 mm, i.d., 1 and 2.1 mm, all packed with Acquity UPLC, BEH-C 18 particles, average d(p) approximately 1.7 microm) and their stainless steel tubes (o.d. 4.53 and 6.35 mm). These columns were kept horizontal and sheltered from forced air convection (i.e., under still air conditions), at room temperature. They were all percolated with pure acetonitrile, either under the maximum pressure drop (1034 bar) or at the maximum flow rate (2 mL/min) permitted by the chromatograph. The heat balance equation of chromatographic columns was discretized and solved numerically with minimum approximation. Both the compressibility and the thermal expansion of the eluent were taken into account. The boundary conditions were determined from the experimental measurements of the column inlet pressure and of the temperature profile along the column wall, which were made with a precision better than +/-0.1 K. These calculation results provide the 3-D temperature profiles along and across the columns. The axial and radial temperature gradients are discussed in relationship with the experimental conditions used. The temperature map obtained permits a prediction of the chromatographic data obtained under a very high pressure gradient.

  13. Purification of coenzyme Q10 from fermentation extract: high-speed counter-current chromatography versus silica gel column chromatography.

    PubMed

    Cao, Xue-Li; Xu, Ya-Tao; Zhang, Guang-Ming; Xie, Sheng-Meng; Dong, Ying-Mao; Ito, Yoichiro

    2006-09-15

    High-speed counter-current chromatography (HSCCC) is applied to the purification of coenzyme Q(10) (CoQ(10)) for the first time. CoQ(10) was obtained from a fermentation broth extract. A non-aqueous two-phase solvent system composed of heptane-acetonitrile-dichloromethane (12:7:3.5, v/v/v) was selected by analytical HSCCC and used for purification of CoQ(10) from 500 mg of the crude extract. The separation yielded 130 mg of CoQ(10) at an HPLC purity of over 99%. The overall results of the present studies show the advantages of HSCCC over an alternative of silica gel chromatography followed by recrystallization. These advantages extend to higher purity (97.8% versus 93.3%), recovery (88% versus 74.3%) and yield (26.4% versus 23.4%). An effort to avoid the toxic, expensive solvent CH(2)Cl(2) was unsuccessful, but at least its percentage is low in the solvent system.

  14. Comparison of chromatographic band profiles obtained under microwave irradiated and non-irradiated reversed-phase liquid chromatography column

    SciTech Connect

    Galinada, Wilmer; Guiochon, Georges A

    2005-08-01

    The possible influence of the application of microwave energy to a reversed-phase liquid chromatography column on the mass transfer kinetics and the thermodynamics of equilibrium between mobile and stationary phases was examined. Chromatograms of propylbenzene and phenol were recorded under the same experimental conditions, on the same column, successively irradiated and not. The effect of microwave irradiation on the mass transfer kinetics was determined by measuring the second moment of small pulses of propylbenzene in a 70:30 (v/v) solution of methanol in water and microwave outputs of 15 and 30 W. The effect of microwave irradiation on the equilibrium thermodynamics was determined by measuring the elution time of breakthrough curves of phenol at high concentrations in a 20:80 (v/v) solution of methanol and water and microwave outputs of 15, 50, and 150 W. A qualitative comparison of the profiles of the propylbenzene peaks obtained with and without irradiation suggests that this irradiation affects significantly the peak shapes. However, a qualitative comparison of the profiles of the breakthrough curves of phenol obtained with and without irradiation suggests that this irradiation has no significant effect on their shapes. The peak sharpening observed may be due to an increase in the diffusivity, resulting from the dielectric polarization under microwave irradiation. This effect is directly related to an increase of the rate of mass transfers in the column. In contrast, the similarity of the overloaded band profiles at high concentrations suggests that the equilibrium thermodynamics is unaffected by microwave irradiation. This may be explained by the transparence of the stationary phase to microwaves at 2.45 GHz. The column temperature was measured at the column outlet under irradiation powers of 15, 30, 50, and 150 W. It increases with increasing power, the corresponding effluent temperatures being 25 {+-} 1, 30 {+-} 1, 35 {+-} 1, and 45 {+-} 1 C, respectively.

  15. Evaluation of sequential injection chromatography for reversed phase separation of triazine herbicides exploiting monolithic and core-shell columns.

    PubMed

    de Prá Urio, Ricardo; Masini, Jorge C

    2015-01-01

    This paper describes the development of reversed phase sequential injection chromatography (SIC) methods for separation of simazine (SIM) and atrazine (AT), as well as their metabolites deethylatrazine (DEA), deisopropylatrazine (DIA) and hydroxyatrazine (HAT) exploiting silica based monolithic (50 × 4.6 mm) and core-shell (30 × 4.6 mm, 2.7 µm particles) columns. The separation was made by stepwise elution with two mobile phases: MP1 composed of 15:85 (v/v) acetonitrile: 2.5 mmol L(-1) acetic acid/ammonium acetate buffer (pH 4.2), and MP2, composed of 35:65 (v/v) acetonitrile: 2.5 mmol L(-1) acetic acid/ammonium acetate buffer (pH 4.2).The less hydrophobic compounds (DIA, HAT and DEA) eluted with MP1, whereas SIM and AT eluted with MP2. The method using core-shell column exhibited better chromatographic efficiency compared with monolithic column for separation of SIM and AT, but failed to provide base line separation of DIA and HAT. The proposed composition of mobile phases enabled the monolithic column to separate all the studied compounds with resolution >2.3 at flow rate of 35 µL s(-1) and sampling throughput of 8 analyses per hour, whereas in the core-shell the maximum flow rate allowed in the SIC system was 8 µL s(-1) (sampling throughput of 3 analyses per hour). The limits of detection were between 24 µg L(-1) (AT) and 40 µg L(-1) (DEA) using the monolithic column, and between 20 µg L(-1) (SIM) and 38 µg L(-1) (DEA) with the core-shell. Ultrasound-assisted extraction (80:20 v/v acetonitrile:water) of a soil sample enriched with the five triazines (250, 500 and 1000 µg kg(-1)) resulted recoveries between 51% and 121% of the spiked concentrations.

  16. Automated Immobilized Metal Affinity Chromatography System for Enrichment of Escherichia coli Phosphoproteome

    SciTech Connect

    Qu, Yi; Wu, Si; Zhao, Rui; Zink, Erika M.; Orton, Daniel J.; Moore, Ronald J.; Meng, Da; Clauss, Therese RW; Aldrich, Joshua T.; Lipton, Mary S.; Pasa-Tolic, Ljiljana

    2013-06-05

    Enrichment of bacterial phosphopeptides is an essential step prior to bottom-up mass spectrometry-based analysis of the phosphoproteome, which is fundamental to understanding the role of phosphoproteins in cell signaling and regulation of protein activity. We developed an automated IMAC system to enrich strong cation exchange-fractionated phosphopeptides from the soluble proteome of Escherichia coli MG1655 grown on minimal medium. Initial demonstration of the system resulted in identification of 75 phosphopeptides covering 52 phosphoproteins. Consistent with previous studies, many of these phosphoproteins are involved in the carbohydrate portion of central metabolism. The automated system utilizes a large capacity IMAC column that can effectively enrich phosphopeptides from a bacterial sample by increasing peptide loading and reducing the wash time. An additional benefit of the automated IMAC system is reduced labor and associated costs.

  17. Heparin-sepharose affinity chromatography for purification of bull seminal-plasma hyaluronidase.

    PubMed Central

    Srivastava, P N; Farooqui, A A

    1979-01-01

    Bull seminal-plasma hyaluronidase was purified 180-fold by chromatography on concanvalin A-Sepharose, heparin Sepharose, Sephadex G-200 and Sephacryl S-200. With hyaluronic acid as the substrate, the specific activity and turnover number of purified hyaluronidase were 3.63 mumol/min per mg (104000 National Formulary units/mg of protein) and 214 min-1 (mol of product formed/mol of enzyme per min) respectively. Polyacrylamide-gel electrophoresis indicated that the purified enzyme migrated as a single band on 7.5 and 10% (w/v) gels at pH 4.3 and 5.3. Bull seminal-plasma hyaluronidase was markedly inhibited by hydroxylamine, phenylhydrazine and semicarbazide. Purified hyaluronidase (1.25 munits; 1 unit = 1 mumol of N-acetylglucosamine liberated/min at 37 degrees C) dispersed the cumulus clot of rabbit ova in 1 h at 22 degrees C. Images Fig. 4. PMID:540029

  18. An illustration of the clinical relevance of detecting human antimouse antibody interference by affinity chromatography.

    PubMed

    Koper, N P; Massuger, L F; Thomas, C M; Beyer, C; Crooy, M J

    1999-10-01

    Elevated Cancer antigen 125 (CA 125) serum concentrations (up to 221 kU/1) were measured in a 39 year old woman with a positive family history of breast cancer. The serum determinations were performed with the automated Immulite OM-MA chemiluminescent enzyme immunoassay system (Diagnostic Products). Laparoscopic evaluation of the ovaries did not reveal any abnormalities. CA 125 measurements in the same patient using the automated IMx immunoassay system (Abbott) demonstrated normal serum levels. Using a previously reported chromatography procedure IgG type human antimouse antibody activity was found to be present in the serum samples explaining the falsely elevated levels. To prevent this interference the manufacturer modified the assay system by replacing the monoclonal M11 detection antibody with a rabbit polyclonal antibody. Using the modified OM-MA CA 125 assay results were comparable with the IMx values.

  19. [Purification of Al13 species in polyaluminum chloride (PAC) by column chromatography and the character of the fractions].

    PubMed

    Chu, Yong-bao; Gao, Bao-yu; Yue, Qin-yan; Wang, Shu-guang; Wang, Yan

    2005-05-01

    The polynuclear keggin species, Al12AlO4(OH)24(H2O)12(7+) (Al13), was separated and purified from polyaluminum chloride (PAC) by column chromatography method. The three fractions were characterized by Al-Ferron timed complexation spectrophotometry, TEM and ZATESIZER tester. Jar tests were performed to test the coagulation efficiency of the three fractions in treating synthetic or actual water samples. The results show that the sample purified by the column chromatography method influenced by the size of the species. The bigger molecules were eluted first, then the smaller ones. Al13 would be obtained by taking out the middle fraction. Compared with the other two fractions, the third fraction gives the best results for turbidity, humic acid and color removal, and achieves the highest charge-neutralizing ability. Al13 species is a higher positive-charged species and can be applied in a wide pH range, and it is much more steady in hydrolyzing process and most effective polymeric Al species in water and wastewater treatment.

  20. Problems in the size exclusion chromatography of poly( N-isopropylacrylamide) on styragel columns

    NASA Astrophysics Data System (ADS)

    Estrin, Ya. I.; Perepelitsina, E. O.; Grishchuk, A. A.

    2016-07-01

    The molecular weights of poly( N-isopropylacrylamide) (PNIPA), calculated according to polystyrene calibration standards upon the elution of THF on styragel columns, appear to be much lower than their actual values determined using independent approaches. This is likely due to interactions between the nitrogen-containing units of PNIPA polymer chains and the sorbent, so the polymer is eluted in the mode intermediate between exclusion and critical. An effective exclusion mode during the elution of PNIPA on a styragel column can be achieved by using an eluent more polar than tetrahydrofuran (particularly, 1-methylpyrrolidone).

  1. Affinity chromatography matrices for depletion and purification of casein glycomacropeptide from bovine whey.

    PubMed

    Baieli, María F; Urtasun, Nicolás; Martinez, María J; Hirsch, Daniela B; Pilosof, Ana M R; Miranda, María V; Cascone, Osvaldo; Wolman, Federico J

    2017-01-01

    Casein glycomacropeptide (CMP) is a 64- amino acid peptide found in cheese whey, which is released after κ-casein specific cleavage by chymosin. CMP lacks aromatic amino acids, a characteristic that makes it usable as a nutritional supplement for people with phenylketonuria. CMP consists of two nonglycosylated isoforms (aCMP A and aCMP B) and its different glycosylated forms (gCMP A and gCMP B). The most predominant carbohydrate of gCMP is N-acetylneuraminic acid (sialic acid). Here, we developed a CMP purification process based on the affinity of sialic acid for wheat germ agglutinin (WGA). After formation of chitosan beads and adsorption of WGA, the agglutinin was covalently attached with glutaraldehyde. Two matrices with different WGA density were assayed for CMP adsorption. Maximum adsorption capacities were calculated according to the Langmuir model from adsorption isotherms developed at pH 7.0, being 137.0 mg/g for the matrix with the best performance. In CMP reduction from whey, maximum removal percentage was 79% (specifically 33.7% of gCMP A and B, 75.8% of aCMP A, and 93.9% of aCMP B). The CMP was recovered as an aggregate with an overall yield of 64%. Therefore, the matrices developed are promising for CMP purification from cheese whey. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 33:171-180, 2017.

  2. Semi-Automated Hydrophobic Interaction Chromatography Column Scouting Used in the Two-Step Purification of Recombinant Green Fluorescent Protein

    PubMed Central

    Murphy, Patrick J. M.

    2014-01-01

    Background Hydrophobic interaction chromatography (HIC) most commonly requires experimental determination (i.e., scouting) in order to select an optimal chromatographic medium for purifying a given target protein. Neither a two-step purification of untagged green fluorescent protein (GFP) from crude bacterial lysate using sequential HIC and size exclusion chromatography (SEC), nor HIC column scouting elution profiles of GFP, have been previously reported. Methods and Results Bacterial lysate expressing recombinant GFP was sequentially adsorbed to commercially available HIC columns containing butyl, octyl, and phenyl-based HIC ligands coupled to matrices of varying bead size. The lysate was fractionated using a linear ammonium phosphate salt gradient at constant pH. Collected HIC eluate fractions containing retained GFP were then pooled and further purified using high-resolution preparative SEC. Significant differences in presumptive GFP elution profiles were observed using in-line absorption spectrophotometry (A395) and post-run fluorimetry. SDS-PAGE and western blot demonstrated that fluorometric detection was the more accurate indicator of GFP elution in both HIC and SEC purification steps. Comparison of composite HIC column scouting data indicated that a phenyl ligand coupled to a 34 µm matrix produced the highest degree of target protein capture and separation. Conclusions Conducting two-step protein purification using the preferred HIC medium followed by SEC resulted in a final, concentrated product with >98% protein purity. In-line absorbance spectrophotometry was not as precise of an indicator of GFP elution as post-run fluorimetry. These findings demonstrate the importance of utilizing a combination of detection methods when evaluating purification strategies. GFP is a well-characterized model protein, used heavily in educational settings and by researchers with limited protein purification experience, and the data and strategies presented here may aid in

  3. Rapid analysis of benzodiazepines in whole blood by high-performance liquid chromatography: use of a monolithic column.

    PubMed

    Bugey, Aurélie; Staub, Christian

    2004-05-28

    In a previous work [J. Pharm. Biomed. Anal. 23 (2000) 447] a rapid high-performance liquid chromatography (HPLC) method, using a monolithic column in HPLC coupled with a diode-array detector, was developed for the quantitative determination of benzodiazepines in whole blood. The present method has been applied to the assay of eight benzodiazepines amongst the most frequently encountered in forensic toxicology: clonazepam, desalkylflurazepam, diazepam, flunitrazepam, lorazepam, midazolam, nordiazepam and oxazepam. The sample pre-treatment involved a liquid-liquid extraction of blood samples by n-butyl chloride. The separation was carried out in reversed-phase conditions using a Chromolith Performance (RP-18e 100 x 4.6 mm) column. The mobile phase was composed of a phosphate buffer (35 mM, pH 2.1) and acetonitrile (70:30, v/v) and the flow-rate was 2 ml/min. The duration of the analysis was less than 4 min and the results of validation, including linearity, precision, recovery, limit of quantification, were satisfactory. The therapeutic and toxic concentrations usually encountered for these substances could be measured. The compounds were separated by a monolithic column which, on account of its particular structure, could bear higher flow-rates than usually found for this kind of analysis. The present method has been applied to two real cases and was tested with about 30 compounds.

  4. Simultaneous speciation of selenoproteins and selenometabolites in plasma and serum by dual size exclusion-affinity chromatography with online isotope dilution inductively coupled plasma mass spectrometry.

    PubMed

    García-Sevillano, M A; García-Barrera, T; Gómez-Ariza, J L

    2014-04-01

    A method for the simultaneous speciation of selenoproteins and selenometabolites in mouse plasma has been developed based on in series two-dimensional size exclusion and affinity high-performance liquid chromatography (2D/SE-AF-HPLC), using two columns of each type, and hyphenation to inductively coupled plasma-(quadrupole) mass spectrometry (ICP-QMS). The method allows the quantitative determination of selenoprotein P (SeP), extracellular glutathione peroxidase (eGPx), selenoalbumin (SeAlb), and selenometabolites in mouse plasma using species-unspecific isotope dilution (SUID). The 2D chromatographic separation is proposed to remove typical spectral interferences in plasma from chloride and bromide on (77)Se ((40)Ar(37)Cl) and (82)Se ((81)Br(1)H). In addition, the approach increases chromatographic resolution allowing the separation of eGPx from Se metabolites of low molecular mass. The method is robust, reliable, and fast with a typical chromatographic runtime less than 20 min. Precision in terms of relative standard deviation (n = 5) is in the order of 4 %, and detection limits are in the range of 0.2 to 1.0 ng Se g(-1). Method accuracy for determination of total protein bound to Se was assessed by analyzing human serum reference material (BCR-637) certified for total Se content, and latterly applied to mouse plasma (Mus musculus). In summary, a reliable speciation method for the analysis of eGPx, selenometabolites, SeP, and SeAlb in plasma/serum samples is proposed for the first time and is applicable to the evaluation of Se status in human in clinical studies and other mammals for environmental or toxicological assessment.

  5. Vacancy ion-exclusion/adsorption chromatography of aliphatic amines on a polymethacrylate-based weakly basic anion-exchange column.

    PubMed

    Mori, Masanobu; Helaleh, Murad I H; Xu, Qun; Hu, Wenzhi; Ikedo, Mikaru; Ding, Ming-Yu; Taoda, Hiroshi; Tanaka, Kazuhiko

    2004-06-11

    Vacancy ion-exclusion/adsorption chromatography has been applied to investigate the separation behavior of five aliphatic amines (ethylamine, propylamine, butylamine, pentylamine and hexylamine) on a polymethacrylate-based weakly basic anion-exchange column (Tosoh TSKgel DEAE-5PW). This system is consisted of analytes as a mobile phase and water as an injected sample. In the vacancy ion-exclusion/adsorption chromatography, the elution order was as follows: ethylamine < propylamine < butylamine < pentylamine < hexylamine, depending on their hydrophobicity. The retention times of the amines were decreased with decreasing their concentrations in the mobile phase. The retention times and resolutions of the amines were increased by adding a basic compound (e.g., lithium hydroxide or heptylamine) and by increasing the pH of mobile phase (pH > 11). This was because the dissociations of amine samples in the mobile phase were suppressed and thus the hydrophobic adsorption effects were enhanced. The linearity of calibration graphs could be obtained from the peak areas of the amine samples injected to the 0.05, 0.5 and 5 mM of amine mobile phase at pH 11 by heptylamine. The detection limits of aliphatic amines as injected samples were around 1 microM for five aliphatic amines at three different amine mobile phases. From these results, the retention behaviors of aliphatic amines on vacancy ion-exclusion/adsorption chromatography were concluded to be governed by the hydrophobic adsorption effect.

  6. Isolation of two molecular populations of human complement factor H by hydrophobic affinity chromatography.

    PubMed Central

    Ripoche, J; Al Salihi, A; Rousseaux, J; Fontaine, M

    1984-01-01

    Human complement factor H was prepared in highly purified form from fresh serum by euglobulin precipitation, DEAE-Sephacel chromatography and Sephacryl S-300 gel filtration. This preparation allowed the recovery of 37% of the initial factor H. Sodium dodecyl sulphate/polyacrylamide-gel electrophoresis revealed that factor H was homogeneous both in reduced and non-reduced media and exhibited a molecular mass of 150 kDa. Charge-shift experiments clearly showed the presence of hydrophobic sites in the factor H molecule. Charge shifts were observed with two detergent systems (Triton/sodium deoxycholate and Triton/cetyltrimethylammonium bromide). Factor H was able to bind to phenyl-Sepharose. This property allowed us to study two populations of factor H. These two populations exhibited the same physicochemical parameters, but revealed differences in their ability to aggregate in low- and iso-ionic-strength media. The molecular basis and biological significance of this heterogeneity are discussed. Images Fig. 3. Fig. 4. Fig. 5. PMID:6235808

  7. Three column intermittent simulated moving bed chromatography: 1. Process description and comparative assessment.

    PubMed

    Jermann, Simon; Mazzotti, Marco

    2014-09-26

    The three column intermittent simulated moving bed (3C-ISMB) process is a new type of multi-column chromatographic process for binary separations and can be regarded as a modification of the I-SMB process commercialized by Nippon Rensui Corporation. In contrast to conventional I-SMB, this enables the use of only three instead of four columns without compromising product purity and throughput. The novel mode of operation is characterized by intermittent feeding and product withdrawal as well as by partial recycling of the weakly retained component from section III to section I. Due to the smaller number of columns with respect to conventional I-SMB, higher internal flow rates can be applied without violating pressure drop constraints. Therefore, the application of 3C-ISMB allows for a higher throughput whilst using a smaller number of columns. As a result, we expect that the productivity given in terms of throughput per unit time and unit volume of stationary phase can be significantly increased. In this contribution, we describe the new process concept in detail and analyze its cyclic steady state behavior through an extensive simulation study. The latter shows that 3C-ISMB can be easily designed by Triangle Theory even under highly non-linear conditions. The simple process design is an important advantage to other advanced SMB-like processes. Moreover, the simulation study demonstrates the superior performance of 3C-ISMB, namely productivity increases by roughly 60% with respect to conventional I-SMB without significantly sacrificing solvent consumption.

  8. Sugar Determination in Foods with a Radially Compressed High Performance Liquid Chromatography Column.

    ERIC Educational Resources Information Center

    Ondrus, Martin G.; And Others

    1983-01-01

    Advocates use of Waters Associates Radial Compression Separation System for high performance liquid chromatography. Discusses instrumentation and reagents, outlining procedure for analyzing various foods and discussing typical student data. Points out potential problems due to impurities and pump seal life. Suggests use of ribose as internal…

  9. A two-column flash chromatography approach to pyoverdin production from Pseudomonas putida GB1.

    PubMed

    Duckworth, Owen W; Markarian, Dawn S; Parker, Dorothy L; Harrington, James M

    2017-04-01

    Our knowledge of the biological and environmental reactivity of siderophores is limited by the difficulty and cost of obtaining reasonable quantities by purification or synthesis. In this note, we describe a modified procedure for the low-cost, mg-scale purification of pyoverdin-type siderophores using a dual-flash chromatography (reverse-phase absorption and size exclusion) approach.

  10. Fabrication and characterization of microelectromechanical systems-based gas chromatography column with embedded micro-posts for separation of environmental carcinogens.

    PubMed

    Sun, Jianhai; Cui, Dafu; Chen, Xing; Zhang, Lulu; Cai, Haoyuan; Li, Hui

    2013-05-24

    In this paper, a micro gas chromatography (μGC) column with embedded micro-posts was developed for increasing overall surface area of the columns which is able to support more of the stationary phase and reducing the effective width of the column, leading to higher separation efficiency. The proposed columns have a higher sample capacity as the overall surface area is about 3 times larger than that of open columns with the same dimensions. In order to achieve an even flow velocity in the channels, the location of the micro-posts in the linear channels and the configuration of curved channels were optimized by numerical simulation. The results have indicated that the proposed column separated 5 environmental carcinogens in less than 50s, achieved a separation efficiency of about 9500plates/m and eluted highly symmetrical Gaussian peaks.

  11. Dielectrophoretic Assembly of Semiconducting Carbon Nanotubes Separated and Enriched by Spin Column Chromatography and Its Application to Gas Sensing

    NASA Astrophysics Data System (ADS)

    Nakano, Michihiko; Fujioka, Masahiro; Mai, Kaori; Watanabe, Hideaki; Martin, Yul; Suehiro, Junya

    2012-04-01

    The present authors have previously demonstrated the electrokinetic fabrication of a single-walled carbon nanotube (SWCNT) gas sensor by employing dielectrophoresis. Because this method employs mass-produced SWCNTs, it can realize cheaper and more flexible SWCNT gas sensor fabrication than that based on the on-site synthesis of SWCNTs. In this study, a new protocol was proposed and tested for the separation and enrichment of semiconducting SWCNTs, aiming to improve the SWCNT gas sensor sensitivity. The protocol employed a spin column filled with size-exclusion dextran-based gel beads as well as two surfactants (sodium dodecyl sulfate and sodium deoxycholate), which had different affinities to metallic and semiconducting SWCNTs. The separation and enrichment of the semiconducting SWCNTs were confirmed by measuring their optical and electrical properties. The CNT gas sensor fabricated using enriched semiconducting SWCNTs was highly sensitive to nitrogen dioxide (NO2) gas, - more sensitive by 10 times than that fabricated using the pristine SWCNT mixture.

  12. Comparative study of glycated hemoglobin by ion exchange chromatography and affinity binding nycocard reader in type 2 diabetes mellitus.

    PubMed

    Gautam, N; Dubey, R K; Jayan, A; Nepaune, Y; Padmavathi, P; Chaudhary, S; Jha, S K; Sinha, A K

    2014-12-01

    The aim of this study was to compare the level of glycated hemoglobin (HbA1c) in type 2 Diabetes Mellitus (DM) patients by two different methods namely Ion Exchange Chromatography and Affinity Binding Nycocard Reader. This is a cross-sectional study conducted on confirmed type 2 diabetes mellitus patients (n = 100) who visited Out Patients Department of the Universal College of Medical Sciences Teaching hospital, Bhairahawa, Nepal from November 2012 to March 2013. The diagnosis of diabetes mellitus was done on the basis of their fasting (164.46 ± 45.33 mg/dl) and random (187.93 ± 78.02 mg/dl) serum glucose level along with clinical history highly suggestive of type 2 DM. The HbA1c values of (7.8 ± 1.9%) and (8.0 ± 2.2%) were found in DM patients as estimated by those two different methods respectively. The highest frequency was observed in HbA1c > 8.0% indicating maximum cases were under very poor glycemic control. However, there were no significant differences observed in HbA1c value showing both methods are comparable in nature and can be used in lab for ease of estimation. The significant raised in HbA1c indicates complications associated with DM and monitoring of therapy become hard for those patients. Despite having standard reference method for HbA1c determination, the availability of report at the time of the patient visit can be made easy by using Nycocard Reader and Ion Exchange Chromatography techniques without any delay in communicating glycemic control, clinical decision-making and changes in treatment regimen.

  13. Determination of citrulline and homocitrulline by high-performance liquid chromatography with post-column derivatization.

    PubMed

    Koshiishi, I; Kobori, Y; Imanari, T

    1990-10-26

    A high-performance liquid chromatographic method was developed for the determination of citrulline and homocitrulline using a post-column colorimetric reaction with o-phthaladehyde and N-(1-naphthyl)-ethylenediamine. Citrulline and homocitrulline were determined with no interferences from protein amino acids. The results show that the level of citrulline in the plasma of patients with uremia on intermittent hemodialysis is higher than that in healthy human plasma, and that homocitrulline is excreted into the urine of healthy adults.

  14. Self-interaction chromatography in pre-packed columns: a critical evaluation of self-interaction chromatography methodology to determine the second virial coefficient.

    PubMed

    Rakel, Natalie; Schleining, Kristina; Dismer, Florian; Hubbuch, Juergen

    2013-06-07

    The characterization of protein-protein interactions is commonly conducted via self-interaction chromatography to describe magnitude and direction of the interactions with the resulting osmotic second virial coefficient (B22). However, the method is invasive and protein immobilization on the adsorber surface can influence the results obtained. In order to replace batch immobilization procedures followed by a column packing, direct on-column preparation was optimized in terms of protein immobilization under a continuous flow. Surface load was measured applying a novel method based on partial least squares analysis of spectral scans to reduce analytical error when determining the amount of immobilized protein. Subsequently influencing parameters such as the effects of absolute surface load, injected protein concentration and distribution of protein orientation were analyzed and system performance evaluated. The results disprove the consistency of the SIC method regarding the non-random orientation of proteins on adsorber particles. Thus the determined B22-values differ quantitatively from those determined with static light scattering. Furthermore, variations in immobilization conditions influence the results obtained. These results make clear that SIC does not fulfill the theoretical framework of B22-analysis. It is rather a qualitative measure of protein-protein interactions in the respective system used for experimentation.

  15. Behavior of short silica monolithic columns in high pressure gas chromatography.

    PubMed

    Maniquet, Adrien; Bruyer, Nicolas; Raffin, Guy; Baco-Antoniali, Franck; Demesmay, Claire; Dugas, Vincent; Randon, Jérôme

    2016-08-19

    In order to analyze light hydrocarbons mixtures with silica monolithic columns, a conventional gas chromatograph was modified to work with carrier gas pressure as high as 60bar. To understand hydrodynamic flow and retention with short columns (less than 30cm), special attention was required due to the temperature difference between the oven area and the FID detector which contain a significant length of the column. Efficiency and selectivity using various carrier gases (helium, nitrogen and carbon dioxide) at different inlet pressure for different oven temperature were studied. Carrier gas nature was a very significant parameter: on one side, linked to adsorption mechanism for gases like nitrogen and carbon dioxide onto the stationary phase modifying retention and selectivity, on the other side in relation to the minimum theoretical plate height which was as low as 15μm (66 000 platem(-1)) using carbon dioxide as carrier gas. The chromatographic system was then used to separate methane, ethane, ethylene, acetylene, propane, cyclopropane, and butane in less than 30s.

  16. Evolution in miniaturized column liquid chromatography instrumentation and applications: An overview.

    PubMed

    Nazario, Carlos E D; Silva, Meire R; Franco, Maraíssa S; Lanças, Fernando M

    2015-11-20

    The purpose of this article is to underline the miniaturized LC instrumental system and describe the evolution of commercially available systems by discussing their advantages and drawbacks. Nowadays, there are already many miniaturized LC systems available with a great variety of pump design, interface and detectors as well as efficient columns technologies and reduced connections devices. The solvent delivery systems are able to drive the mobile phase without flow splitters and promote gradient elution using either dual piston reciprocating or syringe-type pumps. The mass spectrometry as detection system is the most widely used detection system; among many alternative ionization sources direct-EI LC-MS is a promising alternative to APCI. In addition, capillary columns are now available showing many possibilities of stationary phases, inner diameters and hardware materials. This review provides a discussion about miniaturized LC demonstrating fundamentals and instrumentals' aspects of the commercially available miniaturized LC instrumental system mainly nano and micro LC formats. This review also covers the recent developments and trends in instrumentation, capillary and nano columns, and several applications of this very important and promising field.

  17. Critical evaluation and comparison of fluid distribution systems for industrial scale expanded bed adsorption chromatography columns.

    PubMed

    Arpanaei, A; Heebøll-Nielsen, A; Hubbuch, J J; Thomas, O R T; Hobley, T J

    2008-07-11

    The hydrodynamic properties of an expanded bed contactor with 30 cm or 150 cm internal diameter, which employs a rotating or oscillating fluid distributor, were compared to prototype columns of 60 cm or 150 cm diameter employing local stirring (fixed wall nozzles plus central bottom mounted stirrer) for fluid distribution. Fluid introduction through a rotating fluid distributor was found to give superior hydrodynamic characteristics in the 30 cm and 150 cm diameter column compared to using the local stirrer in both the 60 cm and 150 cm diameter columns. The shortcomings of the local stirring distributor at large scale were apparent: dead zones were present which could not be removed by increasing rotation rates or flow rates, and such changes led to a deterioration in hydrodynamic properties. In contrast, during fluid introduction through a rotating distributor no dead zones were observed, and residence time distribution tests showed that plate numbers remained constant or increased slightly as flow rate was raised from 200 cm h(-1) to 470 cm h(-1). Under the conditions studied, oscillation of the rotating fluid distributor led to increased mixing and poorer performance than rotary movement. The results imply that further improvement in distributor design is needed and careful attention should be given to the trade off between turbulence and adequate fluid distribution.

  18. Immobilized metal affinity chromatography in open-loop simulated moving bed technology: purification of a heat stable histidine tagged beta-glucosidase.

    PubMed

    Sahoo, Deepti; Andersson, Jonatan; Mattiasson, Bo

    2009-06-01

    Open-loop simulated moving bed (SMB) has been used for immobilized metal affinity chromatographic (IMAC) purification of his-tagged beta-glucosidase expressed in E. coli. A simplified approach based on an optimized single column protocol is used to design the open-loop SMB. A set of columns in the SMB represent one step in the chromatographic cycle i.e. there will be one set each of columns for load, wash, elution etc within the SMB. Only the wash and elution are operated with columns in sequence. The beta-glucosidase was purified to almost single band purity with a purification factor of 15 and a recovery of 91%. SMB-performance showed reduced buffer consumption, higher purification fold, a better yield and higher productivity.

  19. Preparation of quaternary amine monolithic column for strong anion-exchange chromatography and its application to the separation of Enterovirus 71.

    PubMed

    Gu, Huimin; Yin, Dezhong; Ren, Jie; Zhang, Baoliang; Zhang, Qiuyu

    2016-10-15

    Large size virion is unable to diffuse into pores of conventional porous chromatography particles. Therefore, separation of virion by conventional column-packing materials is not quite efficient. To solve this problem, a monolithic column with large convective pores and quaternary amine groups was prepared and was applied to separate Enterovirus 71 (EV71, ≈5700-6000kDa). Cross-section, pore structure, hydrodynamic performance, adsorption property and dynamic binding capacity of prepared monolithic column were determined. Double-pore structures, macropore at 2472nm and mesopore at 5-60nm, were formed. The porosity was up to 63.3%, which enable higher permeability and lower back pressure of the monolithic column than commercial UNO™ Q1 column. Based on the breakthrough curves, the loading capacity of bovine serum albumin was calculated to be 42.0mg per column. In addition, prepared quaternary amine monolithic column was proved to be suitable for the separation of protein mixture by strong anion-exchange chromatography. As a practical application, prepared monolith column presents excellent performance to the separation of EV71 from virus-proteins mixture.

  20. Monoclonal antibody purification using cationic polyelectrolytes: an alternative to column chromatography.

    PubMed

    Peram, Thanmaya; McDonald, Paul; Carter-Franklin, Jayme; Fahrner, Robert

    2010-01-01

    The potential of cationic polyelectrolytes to precipitate host cell and process related impurities was investigated, to replace one or more chromatography steps in monoclonal antibody purification. The impact of antibody isoelectric point, solution properties (pH and ionic strength), and polyelectrolyte properties (structure, molecular weight and pK(a)) on the degree of precipitation was studied. At neutral pH, increasing solution ionic strength impeded the ionic interaction between the polyelectrolyte and impurities, reducing impurity precipitation. Increasing polyelectrolyte molecular weight and pK(a) enabled precipitation of impurities at higher ionic strength. PoIy(arginine) was selected as the preferred polyelectrolyte in unconditioned cell culture fluid. PoIy(arginine) precipitation achieved consistent host cell protein clearance and antibody recovery for multiple antibodies across a wider range of polyelectrolyte concentrations. Poly(arginine) precipitation was evaluated as a flocculant and as a functional replacement for anion exchange chromatography in an antibody purification process. Upstream treatment of cell culture fluid with poly(arginine) resulted in flocculation of solids (cells and cell debris), and antibody recovery and impurity clearance (host cell proteins, DNA and insulin) comparable to the downstream anion exchange chromatography step.

  1. A Continuous Procedure Based on Column Chromatography to Purify Anthocyanins from Schisandra chinensis by a Macroporous Resin plus Gel Filtration Chromatography.

    PubMed

    Yue, Daran; Yang, Lei; Liu, Shouxin; Li, Jian; Li, Wei; Ma, Chunhui

    2016-02-06

    In our previous study, as natural food colorants and antioxidants, the color and content stabilities of Schisandra chinensis (S. chinensis) anthocyanins were investigated. In this work, the purification process parameters of S. chinensis anthocyanins using a macroporous resin and gel filtration chromatography were evaluated. The optimized parameters of static adsorption and desorption were as follows. The selected resin is HPD-300 (nonpolar copolymer styrene type resin), and the anthocyanins adsorption saturation capacity of HPD-300 resin was 0.475 mg/g dry resin. Adsorption time was 4 h, and 0.517 mg/mL of S. chinensis anthocyanins was adsorbed on the resin column with a flow rate of 39 mL/h (3 BV/h). After adsorption, the anthocyanins were completely desorpted with 2.5 BV of 90% (v/v) ethanol solution, and the desorption flow rate was 13 mL/h (1 BV/h). After purification by dynamic adsorption and desorption, the anthocyanins content in the effluent increased from 47.6 mg/g to 128.4 mg/g, the purity of anthocyanins increased six-fold from 5.08% to 30.43%, and the anthocyanins recovery was 96.5%. The major constituent of S. chinensis anthocyanins was isolated with Bio-Gel P2 gel filtration chromatography, and it was detected by liquid chromatography electrospray ionisation tandem mass spectrometry (LC-ESI-MS) as cyanidin-3-O-xylosylrutinoside. Moreover, the antioxidant activities of S. chinensis anthocyanins were investigated. After purification using the HPD-300 resin, the antioxidant activities of anthocyanins were increased 1.2-fold (FRAP) and 1.7-fold (ABTS).

  2. Chromatography.

    ERIC Educational Resources Information Center

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  3. Purification of a lectin from M. rubra leaves using immobilized metal ion affinity chromatography and its characterization.

    PubMed

    Sureshkumar, Thavamani; Priya, Sulochana

    2012-12-01

    Lectins represent a heterogeneous group of proteins/glycoproteins with unique carbohydrate specificity, with wide range of biomedical applications. The multi-step purification protocols generally used for purification of lectin result in a significant reduction in the final yield and activity. In the present study, Morus rubra lectin (MRL) was purified to homogeneity from the leaves using a single-step immobilized metal ion affinity chromatography (IMAC) procedure. The approximate molecular weight of purified MRL resolved as a single band on SDS-PAGE was 52 kDa. Final percentage yield of purified lectin by IMAC was calculated as 74.7 %. Purified MRL was specific to three sugars, galactose, D-galactosamine and N-acetyl-D-galactosamine, and rendered haemagglutination (HA) activity towards different human blood group RBCs. MRL showed stability over a wide range of temperature (up to 80 °C) and pH (4-11). Chelation of the lectin with EDTA did not alter HA which indicates that metal ion is not required for activity. In the presence of Fe(2+), Ca(2+), Zn(2+), Ni(2+), Mn(2+), Na(+) and K(+), HA activity was reduced to 50 %, whereas the presence of trivalent metal ions (Fe3(+) and Al(3+)) and Cu(2+) did not affect the activity. In the presence of Mg(2+) and Hg(2+), only 25 % of HA activity remained.

  4. Serodiagnosis of human neurocysticercosis using antigenic components of Taenia solium metacestodes derived from the unbound fraction from jacalin affinity chromatography.

    PubMed

    Machado, Gleyce Alves; Oliveira, Heliana Batista de; Gennari-Cardoso, Margareth Leitão; Mineo, José Roberto; Costa-Cruz, Julia Maria

    2013-05-01

    The aim of the present study was to analyse Taenia solium metacestode antigens that were derived from the unbound fraction of jacalin affinity chromatography and subsequent tert-octylphenoxy poly (oxyethylene) ethanol Triton X-114 (TX-114) partitioning in the diagnosis of human neurocysticercosis (NCC). Immunoassays were designed to detect T. solium-specific IgG antibodies by ELISA and immunoblot. Serum samples were collected from 132 individuals who were categorised as follows: 40 had NCC, 62 presented Taenia spp or other parasitic diseases and 30 were healthy individuals. The jacalin-unbound (J unbound ) fraction presented higher sensitivity and specificity rates than the jacalin-bound fraction and only this fraction was subjected to subsequent TX-114 partitioning, resulting in detergent (DJ unbound ) and aqueous (AJ unbound ) fractions. The ELISA sensitivity and specificity were 85% and 84.8% for J unbound , 92.5% and 93.5% for DJ unbound and 82.5% and 82.6% for AJ unbound . By immunoblot, the DJ unbound fraction showed 100% sensitivity and specificity and only serum samples from patients with NCC recognised the 50-70 kDa T. solium-specific components. We conclude that the DJ unbound fraction can serve as a useful tool for the differential immunodiagnosis of NCC by immunoblot.

  5. Inosine 5'-monophosphate dehydrogenase of Escherichia coli. Purification by affinity chromatography, subunit structure and inhibition by guanosine 5'-monophosphate.

    PubMed Central

    Gilbert, H J; Lowe, C R; Drabble, W T

    1979-01-01

    Escherichia coli IMP dehydrogenase (EC 1.2.1.14) was purified by affinity chromatography on immobilized nucleotides. The enzyme binds to agarose-bound 8-(6-aminohexyl)-AMP, N6-(6-aminohexyl)-AMP and 8-(8-amino-octyl)-IMP but not to immobilized NAD+ or Cibacron Blue F3G-A. AMP proved to be an effective eluent. A large-scale purification scheme in which 8-(6-aminohexyl)-AMP-agarose was used resulted in a homogeneous preparation of IMP dehydrogenase. The enzyme was also purified by immunoprecipitation with monospecific antisera. Sodium dodecyl sulphate/polyacrylamide-gel electrophoresis, N-terminal amino acid analysis and tryptic 'finger-printing' demonstrated that IMP dehydrogenase comprises identical subunits of mol.wt. 58000. Trypsin and Pronase cleave the 58000-mol.wt. subunit into peptides of mol.wts. 42000 and 14000, with a concomitant decrease in enzyme activity. These observations rationalize much of the contradictory data on the subunit composition of the enzyme found in the literature. GMP appears to be a competitive inhibitor with respect to IMP, with no evidence for regulatory behaviour being found. The two purification procedures were also used to purify inactive mutant enzymes from guaB mutant strains of E. coli. PMID:44191

  6. Use of Aleuria alantia Lectin Affinity Chromatography to Enrich Candidate Biomarkers from the Urine of Patients with Bladder Cancer

    PubMed Central

    Ambrose, Sarah R.; Gordon, Naheema S.; Goldsmith, James C.; Wei, Wenbin; Zeegers, Maurice P.; James, Nicholas D.; Knowles, Margaret A.; Bryan, Richard T.; Ward, Douglas G.

    2015-01-01

    Developing a urine test to detect bladder tumours with high sensitivity and specificity is a key goal in bladder cancer research. We hypothesised that bladder cancer-specific glycoproteins might fulfill this role. Lectin-ELISAs were used to study the binding of 25 lectins to 10 bladder cell lines and serum and urine from bladder cancer patients and non-cancer controls. Selected lectins were then used to enrich glycoproteins from the urine of bladder cancer patients and control subjects for analysis by shotgun proteomics. None of the lectins showed a strong preference for bladder cancer cell lines over normal urothlelial cell lines or for urinary glycans from bladder cancer patients over those from non-cancer controls. However, several lectins showed a strong preference for bladder cell line glycans over serum glycans and are potentially useful for enriching glycoproteins originating from the urothelium in urine. Aleuria alantia lectin affinity chromatography and shotgun proteomics identified mucin-1 and golgi apparatus protein 1 as proteins warranting further investigation as urinary biomarkers for low-grade bladder cancer. Glycosylation changes in bladder cancer are not reliably detected by measuring lectin binding to unfractionated proteomes, but it is possible that more specific reagents and/or a focus on individual proteins may produce clinically useful biomarkers. PMID:28248271

  7. Glycopeptide Site Heterogeneity and Structural Diversity Determined by Combined Lectin Affinity Chromatography/IMS/CID/MS Techniques

    NASA Astrophysics Data System (ADS)

    Zhu, Feifei; Trinidad, Jonathan C.; Clemmer, David E.

    2015-07-01

    Glycopeptides from a tryptic digest of chicken ovomucoid were enriched using a simplified lectin affinity chromatography (LAC) platform, and characterized by high-resolution mass spectrometry (MS) as well as ion mobility spectrometry (IMS)-MS. The LAC platform effectively enriched the glycoproteome, from which a total of 117 glycopeptides containing 27 glycan forms were identified for this protein. IMS-MS analysis revealed a high degree of glycopeptide site heterogeneity. Comparison of the IMS distributions of the glycopeptides from different charge states reveals that higher charge states allow more structures to be resolved. Presumably the repulsive interactions between charged sites lead to more open configurations, which are more readily separated compared with the more compact, lower charge state forms of the same groups of species. Combining IMS with collision induced dissociation (CID) made it possible to determine the presence of isomeric glycans and to reconstruct their IMS profiles. This study illustrates a workflow involving hybrid techniques for determining glycopeptide site heterogeneity and evaluating structural diversity of glycans and glycopeptides.

  8. Purification of the Plasma Membrane Ca2+-ATPase from Radish Seedlings by Calmodulin-Agarose Affinity Chromatography1

    PubMed Central

    Bonza, Cristina; Carnelli, Antonella; De Michelis, Maria Ida; Rasi-Caldogno, Franca

    1998-01-01

    The Ca2+-ATPase of the plasma membrane (PM) of germinating radish (Raphanus sativus L.) seeds was purified by calmodulin (CaM)-affinity chromatography using a batch procedure. PM purified by aqueous two-phase partitioning was solubilized with n-dodecyl β-d-maltoside and applied to a CaM-agarose matrix. After various washings with decreasing Ca2+ concentrations, the Ca2+-ATPase was eluted with 5 mm ethylenediaminetetraacetate (EDTA). The EDTA-eluted fraction contained about 25% of the loaded Ca2+-ATPase activity, with a specific activity 70-fold higher than that of the starting PM fraction. The EDTA-eluted fraction was highly enriched in a 133-kD polypeptide, which was identified as the PM Ca2+-ATPase by 125I-CaM overlay and fluorescein-isothiocyanate labeling. The PM Ca2+-ATPase cross-reacted with an antiserum against a putative Ca2+-ATPase of the Arabidopsis thaliana chloroplast envelope. PMID:9490776

  9. Optimization of pore structure and particle morphology of mesoporous silica for antibody adsorption for use in affinity chromatography

    NASA Astrophysics Data System (ADS)

    Hikosaka, Ryouichi; Nagata, Fukue; Tomita, Masahiro; Kato, Katsuya

    2016-10-01

    Antibodies have received significant attention for use as antibody drugs, because they bind the objective protein (antigen) via antigen-antibody reactions. Recently, many reports have appeared on various monoclonal antibodies that recognize a single antigen. In this study, monoclonal antibodies are used as adsorbates on mesoporous silica (MPS) for affinity chromatography. MPS has high surface area and large pore volume; moreover, pore diameter, pore structure, and particle morphology are relatively easy to tune by adjusting the conditions of synthesis. The pore structure (two-dimensional (2D) hexagonal and three-dimensional cubic) and particle morphology (spherical and polyhedral) of MPS are optimized for use in a monoclonal antibody/MPS composite. When anti-IgG (one of the monoclonal antibodies) adsorbs on the MPS material and IgG (antigen) binds to anti-IgG/MPS composites, MCM-41p with a 2D-hexagonal pore structure and polyhedral particle morphology has the highest IgG binding efficiency. In addition, the antibody/MPS composites remain stable in chaotropic and low-pH solutions and can be cycled at least five times without decreasing IgG elution. In purification and removal tests, the use of the antibody/MPS composites allows only the objective protein from protein mixtures to be bound and eluted.

  10. Serodiagnosis of human neurocysticercosis using antigenic components of Taenia solium metacestodes derived from the unbound fraction from jacalin affinity chromatography

    PubMed Central

    Machado, Gleyce Alves; de Oliveira, Heliana Batista; Gennari-Cardoso, Margareth Leitão; Mineo, José Roberto; Costa-Cruz, Julia Maria

    2013-01-01

    The aim of the present study was to analyse Taenia solium metacestode antigens that were derived from the unbound fraction of jacalin affinity chromatography and subsequent tert-octylphenoxy poly (oxyethylene) ethanol Triton X-114 (TX-114) partitioning in the diagnosis of human neurocysticercosis (NCC). Immunoassays were designed to detect T. solium-specific IgG antibodies by ELISA and immunoblot. Serum samples were collected from 132 individuals who were categorised as follows: 40 had NCC, 62 presented Taenia spp or other parasitic diseases and 30 were healthy individuals. The jacalin-unbound (Junbound) fraction presented higher sensitivity and specificity rates than the jacalin-bound fraction and only this fraction was subjected to subsequent TX-114 partitioning, resulting in detergent (DJunbound) and aqueous (AJunbound) fractions. The ELISA sensitivity and specificity were 85% and 84.8% for Junbound, 92.5% and 93.5% for DJunboundand 82.5% and 82.6% for AJunbound. By immunoblot, the DJunboundfraction showed 100% sensitivity and specificity and only serum samples from patients with NCC recognised the 50-70 kDa T. solium-specific components. We conclude that the DJunboundfraction can serve as a useful tool for the differential immunodiagnosis of NCC by immunoblot. PMID:23778661

  11. LC-MS/MS quantitation of esophagus disease blood serum glycoproteins by enrichment with hydrazide chemistry and lectin affinity chromatography.

    PubMed

    Song, Ehwang; Zhu, Rui; Hammoud, Zane T; Mechref, Yehia

    2014-11-07

    Changes in glycosylation have been shown to have a profound correlation with development/malignancy in many cancer types. Currently, two major enrichment techniques have been widely applied in glycoproteomics, namely, lectin affinity chromatography (LAC)-based and hydrazide chemistry (HC)-based enrichments. Here we report the LC-MS/MS quantitative analyses of human blood serum glycoproteins and glycopeptides associated with esophageal diseases by LAC- and HC-based enrichment. The separate and complementary qualitative and quantitative data analyses of protein glycosylation were performed using both enrichment techniques. Chemometric and statistical evaluations, PCA plots, or ANOVA test, respectively, were employed to determine and confirm candidate cancer-associated glycoprotein/glycopeptide biomarkers. Out of 139, 59 common glycoproteins (42% overlap) were observed in both enrichment techniques. This overlap is very similar to previously published studies. The quantitation and evaluation of significantly changed glycoproteins/glycopeptides are complementary between LAC and HC enrichments. LC-ESI-MS/MS analyses indicated that 7 glycoproteins enriched by LAC and 11 glycoproteins enriched by HC showed significantly different abundances between disease-free and disease cohorts. Multiple reaction monitoring quantitation resulted in 13 glycopeptides by LAC enrichment and 10 glycosylation sites by HC enrichment to be statistically different among disease cohorts.

  12. Are axial and radial flow chromatography different?

    PubMed

    Besselink, Tamara; van der Padt, Albert; Janssen, Anja E M; Boom, Remko M

    2013-01-04

    Radial flow chromatography can be a solution for scaling up a packed bed chromatographic process to larger processing volumes. In this study we compared axial and radial flow affinity chromatography both experimentally and theoretically. We used an axial flow column and a miniaturized radial flow column with a ratio of 1.8 between outer and inner surface area, both with a bed height of 5 cm. The columns were packed with affinity resin to adsorb BSA. The average velocity in the columns was set equal. No difference in performance between the two columns could be observed. To gain more insight into the design of a radial flow column, the velocity profile and resin distribution in the radial flow column were calculated. Using mathematical models we found that the breakthrough performance of radial flow chromatography is very similar to axial flow when the ratio between outer and inner radius of the radial flow column is around 2. When this ratio is increased, differences become more apparent, but remain small. However, the ratio does have a significant influence on the velocity profile inside the resin bed, which directly influences the pressure drop and potentially resin compression, especially at higher values for this ratio. The choice between axial and radial flow will be based on cost price, footprint and packing characteristics. For small-scale processes, axial flow chromatography is probably the best choice, for resin volumes of at least several tens of litres, radial flow chromatography may be preferable.

  13. Evaluation of octanol-water partition coefficients using capillary gas chromatography with cold on-column injection

    SciTech Connect

    Haky, J.E.; Leja, B.

    1986-01-01

    A general procedure is described for the determination of the octanol-water partition coefficients (log P) of very lipophilic compounds by the shake flask method, employing the analytical technique of capillary gas chromatography with cold on-column injection. The solute and an internal reference with a known log P value are partitioned between the layers of an octanol-water mixture and their relative concentrations are determined by analysis of each phase, using highly standardized chromatographic conditions. The overall method is demonstrated to be convenient, reproducible, and useful for the determination of the partition coefficients of a wide variety of compounds with log P values as high as 5.7. 14 references, 1 figure, 1 table.

  14. Selenium speciation by high-performance anion-exchange chromatography-post-column UV irradiation coupled with atomic fluorescence spectrometry.

    PubMed

    Liang, Lina; Mo, Shumin; Zhang, Ping; Cai, Yaqi; Mou, Shifen; Jiang, Guibin; Wen, Meijuan

    2006-06-16

    A technique for the speciation of selenomethylcysteine (SeMeCys), selenocystine (SeCys), selenite [Se(IV)] and selenomethionine (SeMet) was established in this paper using high-performance anion-exchange chromatography coupled with atomic fluorescence spectrometry (HPAEC-AFS). Analytes were separated on an AminoPac PA10 column and then digested by on-line ultraviolet (UV) irradiation, which destroyed organic compound structure. Hydride generation was used as an available sample introduction technique for atomic fluorescence detection. The detection limits of four compounds were 1-5 microg/L (250 microL injection, 10 times of the baseline noise). The relative standard deviations (RSDs), calculated from seven consecutive injections of 100 microg/L standard mixtures, were from 2 to 4%. Selenious yeast tablet, which had been proposed as selenium supplement, and human urine collected from a volunteer were analyzed. Good spiked recoveries from 86 to 103% were obtained.

  15. The use of a temperature-responsive column for the direct analysis of drugs in serum by two-dimensional heart-cutting liquid chromatography.

    PubMed

    Mikuma, Toshiyasu; Uchida, Ryo; Kajiya, Mizuki; Hiruta, Yuki; Kanazawa, Hideko

    2017-02-01

    A novel pretreatment method, which was performed using a two-dimensional high-performance liquid chromatography (2D-HPLC) system, was proposed for the direct analysis of drugs in human serum. A temperature-responsive column was used as a pretreatment column. The stationary phase of the temperature-responsive column exhibits temperature-regulated hydrophilic/hydrophobic characteristics. Controlling the ionic strength of the eluent enables human serum albumin (HSA) to pass through the column without retention. When serum samples containing barbiturates or benzodiazepines were injected into the temperature-responsive column using 10 mM of ammonium acetate (pH 6.5) as the mobile phase and in the temperature range of 10-40 °C, HSA was eluted from the column near the dead time, followed by the individual drugs. When the column temperature was changed, the retention times of the drugs were altered owing to surface property changes within the pretreatment column. These closely eluted compounds were subsequently introduced into the analytical column using a column-switching valve, with a minimal gap time to avoid foreign substance contamination. This new 2D-HPLC method afforded high-quality chromatograms of multiple drugs without unwanted peaks from foreign substances. The present technique could be an attractive choice in selecting the analytical method for drug analysis.

  16. A general method for fractionation of plasma proteins. Dye-ligand affinity chromatography on immobilized Cibacron blue F3-GA.

    PubMed

    Gianazza, E; Arnaud, P

    1982-01-01

    The chromatographic behaviour of 27 different plasma proteins on fractionation of human plasma on immobilized Cibacron Blue F3-GA was studied. The column was eluted by using a three-step procedure. First, a low-molarity buffer (30 mM-H3PO4/Na3PO4, pH 7.0, I0.053) was used, then a linear salt gradient (0-1 M-NaCl in the buffer above) was applied, followed by a wash with two bed volumes of 1.0 M-NaCl. Finally, bound proteins were 'stripped' with 0.5 M-NaSCN. Up to 1 ml of whole plasma could be loaded per 5 ml bed volume. No denaturation of proteinase inhibitors or complement fractions was observed. The recovery of individual proteins ranged between 52 and greater than 95%. Enrichment of four individual plasma components (alpha 1-antitrypsin, caeruloplasmin, antithrombin III and haemopexin) was between 10-fold and 75-fold. These results indicate that chromatography on immobilized Cibacron Blue F3-GA can be a useful initial step in the purification of plasma proteins.

  17. Kinetic performance of a 50mm long 1.8μm chiral column in supercritical fluid chromatography.

    PubMed

    Berger, Terry A

    2016-08-12

    Reduced plate heights (hr) of <2 were observed for the first time during the chiral separation of enantiomers, on sub-2μm particles with supercritical fluid chromatography (SFC). The enantiomers of trans-stilbene oxide, were separated on a 4.6×50mm, 1.8μm R,R-Whelk-O1 column, with hr as low as 1.93. The plumbing of a commercial SFC instrument was modified to create a low dispersion version. Without the modification performance was considerably worse. vanDeemter like plots of reduced plate height vs. flow rate, for trans-stilbene oxide, indicate that the optimum flow varied with% modifier. On a 4.6×250mm, 5μm R,R- Whelk-O1 column, the optimum flow was >4mL/min for 5% methanol in CO2, decreasing to <2mL/min for 40% methanol (more than a factor of 2). For a 4.6×50mm column packed with 1.8μm particles the optimum appeared to be near, or >5mL/min with 2.5%, 5%, and 10% methanol, decreasing to between 3 and 3.5mL/min at 40% methanol. This is the first time such shifts have been characterized. Since the solutes were the same in all cases, the differences are likely due to changes in solute diffusion coefficients caused by changes in modifier concentration, and pressure. Pump pressure requirements sometimes exceeded 500bar. It is shown that a 5mL/min flow rate is inadequate for use with 1.8μm particles in a 4.6mm ID column format. Instead, it is suggested to decrease the ID of the column to 3mm, where the optimum flow rates are on the order of 2mL/min with decreased tubing variance. Nevertheless, a number of sub-1min chromatograms are presented.

  18. Parallel extraction columns and parallel analytical columns coupled with liquid chromatography/tandem mass spectrometry for on-line simultaneous quantification of a drug candidate and its six metabolites in dog plasma.

    PubMed

    Xia, Y Q; Hop, C E; Liu, D Q; Vincent, S H; Chiu, S H

    2001-01-01

    A method with parallel extraction columns and parallel analytical columns (PEC-PAC) for on-line high-flow liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated for simultaneous quantification of a drug candidate and its six metabolites in dog plasma. Two on-line extraction columns were used in parallel for sample extraction and two analytical columns were used in parallel for separation and analysis. The plasma samples, after addition of an internal standard solution, were directly injected onto the PEC-PAC system for purification and analysis. This method allowed the use of one of the extraction columns for analyte purification while the other was being equilibrated. Similarly, one of the analytical columns was employed to separate the analytes while the other was undergoing equilibration. Therefore, the time needed for re-conditioning both extraction and analytical columns was not added to the total analysis time, which resulted in a shorter run time and higher throughput. Moreover, the on-line column extraction LC/MS/MS method made it possible to extract and analyze all seven analytes simultaneously with good precision and accuracy despite their chemical class diversity that included primary, secondary and tertiary amines, an alcohol, an aldehyde and a carboxylic acid. The method was validated with the standard curve ranging from 5.00 to 5000 ng/mL. The intra- and inter-day precision was no more than 8% CV and the assay accuracy was between 95 and 107%.

  19. Aflatoxin evaluation in ready-to-eat brazil nuts using reversed-phase liquid chromatography and post-column derivatisation.

    PubMed

    Iamanaka, Beatriz Thie; Nakano, Felipe; Lemes, Daniel Ponciano; Ferranti, Larissa Souza; Taniwaki, Marta Hiromi

    2014-01-01

    A high-performance liquid chromatography-fluorescence (HPLC-FD) method for aflatoxin quantification in brazil nuts was developed. Samples of brazil nuts collected in Brazilian markets were extracted with methanol:water and cleaned using an immunoaffinity column. Aflatoxins were eluted with methanol and a post-column derivatisation was performed with bromine, using a Kobra Cell system. The optimised method for total aflatoxins was sensitive, with detection and quantification limits of 0.05 and 0.25 µg kg⁻¹, respectively. The method was accurate, with recovery values of 87.6%; 85.3% and 85.0% for 0.5, 5.0 and 14.6 µg kg⁻¹ spiked levels, respectively. It was shown that the method was applicable to brazil nuts. From a total of 95 brazil nut samples analysed from 21 São Paulo supermarket samples and 51 Manaus and 23 Belém street markets samples, 37.9% showed detectable levels of aflatoxins and three exceeded the recommended Codex Alimentarius limit of 10 µg kg⁻¹ for ready-to-eat brazil nuts.

  20. Packing of large-scale chromatography columns with irregularly shaped glass based resins using a stop-flow method

    PubMed Central

    Siu, Sun Chau; Chia, Celeste; Mok, Yanglin; Pattnaik, Priyabrata

    2014-01-01

    Rigid chromatography resins, such as controlled pore glass based adsorbents, offer the advantage of high permeability and a linear pressure-flow relationship irrespective of column diameter which improves process time and maximizes productivity. However, the rigidity and irregularly shaped nature of these resins often present challenges in achieving consistent and uniform packed beds as formation of bridges between resin particles can hinder bed consolidation. The standard flow-pack method when applied to irregularly shaped particles does not yield well-consolidated packed beds, resulting in formation of a head space and increased band broadening during operation. Vibration packing methods requiring the use of pneumatically driven vibrators are recommended to achieve full packed bed consolidation but limitations in manufacturing facilities and equipment may prevent the implementation of such devices. The stop-flow packing method was developed as an improvement over the flow-pack method to overcome these limitations and to improve bed consolidation without the use of vibrating devices. Transition analysis of large-scale columns packed using the stop-flow method over multiple cycles has shown a two- to three-fold reduction of change in bed integrity values as compared to a flow-packed bed demonstrating an improvement in packed bed stability in terms of the height equivalent to a theoretical plate (HETP) and peak asymmetry (As). PMID:25080096

  1. Analysis of trace inorganic anions in weak acid salts by single pump cycling-column-switching ion chromatography.

    PubMed

    Huang, Zhongping; Ni, Chengzhu; Zhu, Zhuyi; Pan, Zaifa; Wang, Lili; Zhu, Yan

    2015-05-01

    The application of ion chromatography with the single pump cycling-column-switching technique was described for the analysis of trace inorganic anions in weak acid salts within a single run. Due to the hydrogen ions provided by an anion suppressor electrolyzing water, weak acid anions could be transformed into weak acids, existing as molecules, after passing through the suppressor. Therefore, an anion suppressor and ion-exclusion column were adopted to achieve on-line matrix elimination of weak acid anions with high concentration for the analysis of trace inorganic anions in weak acid salts. A series of standard solutions consisting of target anions of various concentrations from 0.005 to 10 mg/L were analyzed, with correlation coefficients r ≥ 0.9990. The limits of detection were in the range of 0.67 to 1.51 μg/L, based on the signal-to-noise ratio of 3 and a 25 μL injection volume. Relative standard deviations for retention time, peak area, and peak height were all less than 2.01%. A spiking study was performed with satisfactory recoveries between 90.3 and 104.4% for all anions. The chromatographic system was successfully applied to the analysis of trace inorganic anions in five weak acid salts.

  2. Preparative separation of gallocatechin gallate from Camellia ptilophylla using macroporous resins followed by sephadex LH-20 column chromatography.

    PubMed

    Li, Kaikai; Zhou, Xuelin; Liu, Cheuk-Lun; Yang, Xiaorong; Han, Xiaoqiang; Shi, Xianggang; Song, Xiaohong; Ye, Chuangxing; Ko, Chun-hay

    2016-02-01

    Gallocatechin gallate (GCG) possesses multiple potential biological activities. However, the content of GCG in traditional green tea is too low which limits its in-depth pharmacological research and application. In the present study, a simple, efficient and environment-friendly chromatographic separation method was developed for preparative enrichment and separation of GCG from cocoa tea (Camellia ptilophylla) which contains high content of GCG. In the first step, the adsorption properties of selected resins were evaluated, and XAD-7HP resin was chosen by its adsorption and desorption properties for GCG. In order to maximize column efficiency for GCG collection, the operating parameters (e.g., flow rate, ethanol concentration, and bed height) were optimized. We found that the best combination was the feed concentration at 20mg/mL, flow rate at 0.75 BV/h and the ratio of diameter to bed heights as 1:12. Under these conditions, the purity of GCG was 45% with a recovery of 89%. In order to obtain pure target, a second step was established using column chromatography with sephadex LH-20 gel and 55% ethanol-water solution as eluent. After this step, the purity of the GCG was 91% with a recovery of 68% finally.

  3. [Determination of histamine in canned fish by high performance liquid chromatography with pre-column derivatization].

    PubMed

    Jin, Gaowa; Cai, Youqiong; Yu, Huijuan; Qian, Beilei

    2010-11-01

    A pre-column derivatization-high performance liquid chromatographic (HPLC) method has been developed for the determination of histamine in canned fish. The homogenated samples were ultrasonically extracted with perchloric acid aqueous solution, derivatized with dansyl chloride and diluted with acetonitrile to a desired volume. The samples were determined by HPLC with ultraviolet detector and quantified by external standard method. Adopting a C18 column with 1.8 microm stationary phase particles, the analysis time for each sample was smaller than 5 min with the flow rate of 0.3 mL/min. It can decrease the consumption of the mobile phase and save the cost. The linear range was 0.08-8.00 mg/L for histamine. The correlation coefficient was 0.999 98. The average recoveries of histamine at different concentration levels in spiked samples were greater than 96% and the relative standard deviations (RSDs) were smaller than 2.5%. The quantitation limit was 5.00 mg/kg for histamine in canned fish by HPLC. The results indicated that this HPLC method is fast, sensitive, reproducible and practical for the routine analysis of histamine in canned fish.

  4. Spiral column configuration for protein separation by high-speed countercurrent chromatography

    PubMed Central

    Ito, Yoichiro

    2009-01-01

    Retention of the stationary phase of aqueous-aqueous polymer phase systems is improved by a spiral column configuration which utilizes the radially acting centrifugal force along the spiral pitch to retain the heavier phase in the outer portion and the lighter phase in the inner portion of the spiral channel. For the separation of proteins which has low mass transfer rates, the system needs further modification of the separation channel to interrupt the laminar flow and enhance mixing of the two phases. Two spiral column assemblies were developed, one using a disk with spiral grooves and the other, the spiral tube support which accommodates the multiple spiral layers made from a single piece of fluorinated plastic tubing. In the spiral disk assembly, the best protein separation is achieved by the mixer-settler system which vigorously mixes two phases by vibrating glass beads placed in every other section of barricaded spiral channel, while in the spiral tube assembly the partition efficiency of proteins is enhanced by compressing the tubing to interrupt the laminar flow of the mobile phase. In both systems protein samples were well resolved by choosing the suitable elution modes. PMID:20823942

  5. Enantiomeric separation of asymmetric triacylglycerol by recycle high-performance liquid chromatography with chiral column.

    PubMed

    Nagai, Toshiharu; Mizobe, Hoyo; Otake, Ikuko; Ichioka, Kenji; Kojima, Koichi; Matsumoto, Yumiko; Gotoh, Naohiro; Kuroda, Ikuma; Wada, Shun

    2011-05-20

    In our previous studies, we employed recycle HPLC for the separation of triacylglycerol (TAG)-positional isomers (PIs). In this study, a recycle HPLC system equipped with a polysaccharide-based chiral column was applied to the enantiomeric separation of some asymmetric TAGs having straight-chain C16-C18 acyl residues. As a result, 1,2-dipalmitoyl-3-oleoyl-rac-glycerol (rac-PPO), 1,2-dioleoyl-3-palmitoyl-rac-glycerol (rac-OOP), and 1,2-dipalmitoyl-3-linoleoyl-rac-glycerol (rac-PPL) were resolved into their respective enantiomers. However, neither 1,2-dioleoyl-3-linoleoyl-rac-glycerol (rac-OOL), consisting of only unsaturated fatty acids, nor 1,2-dipalmitoyl-3-stearoyl-rac-glycerol (rac-PPS), consisting of only saturated fatty acids, was resolved. These results suggest that the asymmetric TAGs, used in this study, having both a palmitic acid moiety and an oleic acid (or a linoleic acid) moiety at the sn-1 or sn-3 positions are resolved by the chiral column. This new chiral separation method can be used in combination with atmospheric pressure chemical ionization mass spectrometry to determine the sn-OOP/sn-POO ratio in palm oil. This method is applicable for the chiral separation of asymmetric TAGs in palm oil.

  6. Application of isothermal titration calorimetry and column chromatography for identification of biomolecular targets.

    PubMed

    Zhou, Xingding; Kini, R Manjunatha; Sivaraman, J

    2011-02-01

    This protocol describes a method for identifying unknown target proteins from a mixture of biomolecules for a given drug or a lead compound. This method is based on a combination of chromatography and isothermal titration calorimetry (ITC) where ITC is used as a tracking tool. The first step involves the use of ITC to confirm the binding of ligand to a component in the biomolecular mixture. Subsequently, the biomolecular mixture is fractionated by chromatography, and the binding of the ligand with individual fractions (or subfractions) is verified by ITC. The iteration of chromatographic purification on the fractions combined with ITC results in identifying the target protein. This method is useful when the target protein or ligand is unknown and/or not amenable to labeling, chemical modification or immobilization. This protocol has been successfully used by our team and by others to identify both low-abundance and highly abundant target proteins present in biomolecular mixtures. With this protocol, it takes approximately 3-5 d to identify the target protein from a mixture.

  7. [Determination of 14 sulfonamide residues in shrimps by high performance liquid chromatography coupled with post-column derivatization].

    PubMed

    Huang, Dongmei; Huang, Xuanyun; Gu, Runrun; Hui, Yunhua; Tian, Liangliang; Feng, Bing; Zhang, Xuan; Yu, Huijuan

    2014-08-01

    A method for the determination of 14 sulfonamide residues in shrimps by high performance liquid chromatography coupled with post-column derivatization was established. The sulfonamide residues were extracted with ethyl acetate after adding sulfapyridine as internal standard. The extracts were vacuum-concentrated and reverse-extracted by 2 mol/L hydrochloric acid solution for clean-up, and then the hydrochloric acid solution was defatted with n-hex- ane. The solution after filtration was blended with a mixed solution of methanol, acetonitrile and 3. 5 mol/L sodium acetate solution (5:5:20, v/v/v). The sulfonamides were separated on a C18 column by RP-HPLC and on-line derivatized with a fluorescamine and detected with a fluorescence detector. The standard addition method was used for quantitative analysis. The parameters of post-column derivatization system, such as concentration of fluorescamine solution, velocity of reagent solution and reaction temperature, were optimized. The calibration curves of the method showed good linearity in the range of 5 - 200 μg/L. The limits of quantification (LOQ, S/N= 10) were 1.0-5.0 μg/kg for the 14 sulfonamides. The recoveries were 77.8%- 103. 6% in the spiked range of 1. 0-100.0 μg/kg in shrimps with the relative standard deviations of 2.9%-9.1% (n= 6). The results indicated that the method is sensitive, efficient and more accurate. It is suitable for the simultaneous determination of the 14 sulfonamide residues in shrimps.

  8. Rapid bioanalysis of vancomycin in serum and urine by high-performance liquid chromatography tandem mass spectrometry using on-line sample extraction and parallel analytical columns.

    PubMed

    Cass, R T; Villa, J S; Karr, D E; Schmidt, D E

    2001-01-01

    A novel high-performance liquid chromatography tandem mass spectrometry (LC/MS/MS) method is described for the determination of vancomycin in serum and urine. After the addition of internal standard (teicoplanin), serum and urine samples were directly injected onto an HPLC system consisting of an extraction column and dual analytical columns. The columns are plumbed through two switching valves. A six-port valve directs extraction column effluent either to waste or to an analytical column. A ten-port valve simultaneously permits equilibration of one analytical column while the other is used for sample analysis. Thus, off-line analytical column equilibration time does not require mass spectrometer time, freeing the detector for increased sample throughput. The on-line sample extraction step takes 15 seconds followed by gradient chromatography taking another 90 seconds. Having minimal sample pretreatment the method is both simple and fast. This system has been used to successfully develop a validated positive-ion electrospray bioanalytical method for the quantitation of vancomycin. Detection of vancomycin was accurate and precise, with a limit of detection of 1 ng/mL in serum and urine. The calibration curves for vancomycin in rat, dog and primate were linear in a concentration range of 0.001-10 microg/mL for serum and urine. This method has been successfully applied to determine the concentration of vancomycin in rat, dog and primate serum and urine samples from pharmacokinetic and urinary excretion studies.

  9. Quantitative Evaluation of Models for Solvent-based, On-column Focusing in Liquid Chromatography

    PubMed Central

    Groskreutz, Stephen R.; Weber, Stephen G.

    2015-01-01

    On-column focusing or preconcentration is a well-known approach to increase concentration sensitivity by generating transient conditions during the injection that result in high solute retention. Preconcentration results from two phenomena: 1) solutes are retained as they enter the column. Their velocities are k′-dependent and lower than the mobile phase velocity and 2) zones are compressed due to the step-gradient resulting from the higher elution strength mobile phase passing through the solute zones. Several workers have derived the result that the ratio of the eluted zone width (in time) to the injected time width is the ratio k2/k1 where k1 is the retention factor of a solute in the sample solvent and k2 is the retention factor in the mobile phase (isocratic). Mills et al. proposed a different factor. To date, neither of the models has been adequately tested. The goal of this work was to evaluate quantitatively these two models. We used n-alkyl esters of p-hydroxybenzoic acid (parabens) as solutes. By making large injections to create obvious volume overload, we could measure accurately the ratio of widths (eluted/injected) over a range of values of k1 and k2. The Mills et al. model does not fit the data. The data are in general agreement with the factor k2/k1, but focusing is about 10% better than the prediction. We attribute the extra focusing to the fact that the second, compression, phenomenon provides a narrower zone than that expected for the passage of a step gradient through the zone. PMID:26210110

  10. A column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry method to determine anandamide and 2-arachidonoylglycerol in plasma samples.

    PubMed

    Marchioni, Camila; de Souza, Israel Donizeti; Grecco, Caroline Fernandes; Crippa, José Alexandre; Tumas, Vitor; Queiroz, Maria Eugênia Costa

    2017-03-23

    This study reports a fast, sensitive, and selective column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to determine the endocannabinoids (eCBs), anandamide (AEA), and 2-arachidonoylglycerol (2-AG) in plasma samples. This bidimensional system used a restricted access media column (RP-8 ADS, 25 mm × 4 mm × 25 μM) in the first dimension and a core-shell Kinetex C18 (100 mm × 2, 1.7 mm × 1 μM) column in the second dimension, followed by detection in a mass spectrometer triple quadrupole (multiple reactions monitoring mode) operating in the positive mode. RP-8 ADS was used for trace enrichment of eCBs (reverse phase partitioning) and macromolecular matrix size exclusion; the core-shell column was used for the chromatographic separation. The column switching UHPLC-MS/MS method presented a linear range spanning from 0.1 ng mL(-1) (LOQ) to 6 ng mL(-1) for AEA and from 0.04 ng mL(-1) (LOQ) to 10 ng mL(-1) for 2-AG. Excluding the LLOQ values, the precision assays provided coefficients of variation lower than 8% and accuracy with relative standard error values lower than 14%. Neither carryover nor matrix effects were detected. This high-throughput column switching method compared to conventional methods is time saving as it involves fewer steps, consumes less solvent, and presents lower LLOQ. The column switching UHPLC-MS/MS method was successfully applied to determine AEA and 2-AG in plasma samples obtained from Alzheimer's disease patients. Graphical abstract A column switching ultra high-performance liquid chromatography-tandem mass spectrometry method using RP-8 ADS column and core shell column to determine endocannabinoids in plasma samples.

  11. Purification of biologically active human plasma transthyretin by dye-affinity chromatography: studies on dye leakage and possibility of heat treatment for virus inactivation.

    PubMed

    Regnault, V; Rivat, C; Vallar, L; Geschier, C; Stolz, J F

    1992-12-11

    The application of a purification procedure for the industrial preparation from human plasma of a therapeutic protein may be hindered by several safety concerns. The dye leaching from Remazol Yellow GGL-Sepharose used for the affinity chromatography of human plasma transthyretin was quantitatively studied by a sensitive competitive enzyme immunoassay. The possibility of including a heat treatment step for virus inactivation in the purification process while preserving the biochemical and functional characteristics of the protein is also reported.

  12. The Trace Analysis of DEET in Water using an On-line Preconcentration Column and Liquid Chromatography with UV Photodiode Array Detection

    EPA Science Inventory

    A method for the detection of trace levels of N,N-diethyl-m-toluamide (DEET) in water is discussed. The method utilizes an on-line preconcentration column in series with high performance liquid chromatography (HPLC) and UV photodiode array detection. DEET, a common insect repel...

  13. Determination of citrus limonoid glucosides by high performance liquid chromatography coupled to post-column reaction with Ehrlich’s Reagent

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A method for the identification and quantification of citrus limonoid glucosides in juices based upon high performance liquid chromatography (HPLC) separation coupled to post-column reaction with Ehrlichs’s reagent has been developed. This method utilizes a phenyl stationary phase and an isocratic ...

  14. Separation of the Components of a Commercial Analgesic Tablet: A Two-Week Sequence Comparing Purification by Two-Base Extraction and Column Chromatography

    ERIC Educational Resources Information Center

    Revell, Kevin D.

    2011-01-01

    A new laboratory experiment is described in which students compare two benchtop separation methods to isolate the three active components of the commercial analgesic Excedrin. In the two-week sequence, aspirin, acetaminophen, and caffeine are separated using either a two-base liquid-liquid extraction or silica column chromatography. Students then…

  15. Regenerated bacterial cellulose microfluidic column for glycoproteins separation.

    PubMed

    Chen, Chuntao; Zhu, Chunlin; Huang, Yang; Nie, Ying; Yang, Jiazhi; Shen, Ruiqi; Sun, Dongping

    2016-02-10

    To analysis and separate glycoproteins, a simple strategy to prepare regenerated bacterial cellulose (RBC) column with concanavalin A (Con A) lectin immobilized in microfluidic system was applied. RBC was filled into microchannel to fabricate RBC microcolumn after bacterial cellulose dissolved in NaOH-sulfourea water solution. Lectin Con A was covalently connected onto RBC matrix surface via Schiff-base formation. Lysozyme (non-glycoprotein) and transferrin (glycoprotein) were successfully separated based on their different affinities toward the immobilized Con A. Overall, the RBC microfluidic system presents great potential application in affinity chromatography of glycoproteins analysis, and this research represents a significant step to prepare bacterial cellulose (BC) as column packing material in microfluidic system. What is more, troublesome operations for lectin affinity chromatography were simplified by integrating the microfluidic chip onto a HPLC (High Performance Liquid Chromatography) system.

  16. Affinity Monolith-Integrated Microchips for Protein Purification and Concentration.

    PubMed

    Gao, Changlu; Sun, Xiuhua; Wang, Huaixin; Qiao, Wei; Hu, Bo

    2016-01-01

    Affinity chromatography is a valuable method to purify and concentrate minute amount of proteins. Monoliths with epoxy groups for affinity immobilization were prepared by direct in-situ photopolymerization of glycidyl methacrylate and ethylene glycol dimethacrylate in porogenic solvents consisting of 1-dodecanol and cyclohexanol. By integrating affinity monoliths onto a microfluidic system, targeted biomolecules can be captured and retained on affinity column, while other biomolecules having no specific interactions toward the immobilized ligands flow through the microchannel. Therefore, proteins which remain on the affinity column are purified and concentrated, and then eluted by appropriate solutions and finally, separated by microchip capillary electrophoresis. This integrated microfluidic device has been applied to the purification and separation of specific proteins (FITC-labeled human serum albumin and IgG) in a mixture.

  17. Polymer-based monolithic column with incorporated chiral metal-organic framework for enantioseparation of methyl phenyl sulfoxide using nano-liquid chromatography.

    PubMed

    Wang, Xin; Lamprou, Alexandros; Svec, Frantisek; Bai, Yu; Liu, Huwei

    2016-12-01

    A new approach to the preparation of enantioselective porous polymer monolithic columns with incorporated chiral metal-organic framework for nano-liquid chromatography has been developed. While no enantioseparation was achieved with monolithic poly(4-vinylpyridine-co-ethylene dimethacrylate) column, excellent separations of both enantiomers of (±)-methyl phenyl sulfoxide were achieved with its counterpart prepared after admixing metal-organic framework [Zn2 (benzene dicarboxylate)(l-lactic acid)(dmf)], which is synthesized from zinc nitrate, l-lactic acid, and benzene dicarboxylic acid in the polymerization mixture. These novel monolithic columns combined selectivity of the chiral framework with the excellent hydrodynamic properties of polymer monoliths, may provide a great impact on future studies in the field of chiral analysis by liquid chromatography.

  18. Characterization of warfarin unusual peak profiles on oligoproline chiral high performance liquid chromatography columns.

    PubMed

    Lao, Wenjian; Gan, Jay

    2010-10-15

    Unusual peak profiles of warfarin were characterized on two oligoproline chiral stationary phases (CSPs). The pattern of 1st peak (S(-)) broadening and the 2nd peak (R(+)) compression was observed under mobile phase of hexane (0.1% TFA)/2-propanol (IPA) on a triproline CSP 1, and with other alcohol modifier such as ethanol, 1-propanol, 1-butanol, 2-butanol, and tert-butanol as well. Through analyzing system peak of additives, the unusual peak profile was interpreted by perturbation of TFA additive system peak. The unusual peak profile was also found in enantioseparation of coumachlor and on a covalently bonded doubly tethered diproline CSP 2. The pattern of 1st peak (S(-)) broadening and the 2nd peak (R(+)) compression can change to pattern of 1st peak compression and the 2nd peak broadening from 15 to 50°C. Chiral separation of warfarin created nonlinear van't Hoff plots on CSP. No peak broadening/compression were observed with methyl tertiary butyl ether or ethyl acetate as the modifier. The peak shapes of the two warfarin enantiomers can thus be tuned by varying alcohol concentration and column temperature. High separation factor and resolution may be carried out to tune the peak profiles into Langmuir/anti-Langmuir band-shape composition. Using none hydrogen donor modifier may avoid interference of the TFA system peak.

  19. Packed column supercritical fluid chromatography of hydrophilic analytes via water-rich modifiers.

    PubMed

    Taylor, Larry T

    2012-08-10

    The use of additives to dramatically extend the range of solute polarity amenable to CO(2) based supercritical fluid chromatography (pcSFC) was predicted over 20 years ago. At that time additives were predicted to have multiple functions such as enhancement of mobile phase solvating power, ion suppression, and ion pairing. The adsorption of mobile phase components on the stationary phase causing a modification of its surface was predicted, but the implications for separations were not defined. Reports published in the late 1980s showed that while water could not function as a primary modifier due to it poor solubility in carbon dioxide, its use as an additive was more promising. The past decade has seen very little published work concerning water and pcSFC. Now reports are beginning to appear that demonstrate enhanced selectivity with water, and application of the technology to polypeptide salts, drug molecules, and nucleobases. This review attempts to bridge the past with the present. As evidenced by the studies described in this review, water may offer much potential as an additive in that it could (a) enhance the solvating power of the mobile phase, (b) introduce HILIC-like analyte partitioning, (c) simplify preparative purifications, and (d) offer a more mass spectrometrically compatible interface.

  20. Performance limits and kinetic optimization of parallel and serially connected multi-column systems spanning a wide range of efficiencies for liquid chromatography.

    PubMed

    Cabooter, Deirdre; Desmet, Gert

    2012-01-06

    Using a set of experimentally determined liquid chromatography column performance data, it has been investigated how a range of efficiencies can best be covered when using a multi-column system. Two main variants are considered: a serially-connected variant (realizing different column lengths by connecting a different number of column segments in series) and a parallel-connected variant (realizing different column lengths by simply switching between columns with a different length arranged in parallel). Both variants are compared for their ability to keep the average analysis time along a given range of efficiencies as close as possible to the intrinsic Knox & Saleem-speed limit. It was found that the serial connection mode offers a better compromise between average speed and amount of required silica (total required column length) than the parallel connection mode for all efficiency ranges running from 5000-10,000 plates up to 75,000-150,000 plates. Considering an ultra-high performance liquid chromatography (UHPLC) operation at 1200 bar, the best possible serial connection system can get within about within 15-25% of the Knox & Saleem-speed limit, whereas a three-column parallel system can only get to within 40-50% of the speed limit, while needing 50-100% more total column length. In absolute terms, the serially-connected system with individually optimized segment lengths should be able to cover a range of 5000-75,000 theoretical plates (dynamic range of 25) in an average analysis time of 14.3 min when using a 1200 bar instrument. At 400 bar, this would be 37.9 min, showing that the construction of wide-efficiency range systems would be one of the application areas where the advantages of UHPLC-conditions would be most fully realized.

  1. Scale-up protein separation on stainless steel wide bore toroidal columns in the type-J counter-current chromatography.

    PubMed

    Guan, Yue Hugh; Hewitson, Peter; van den Heuvel, Remco N A M; Zhao, Yan; Siebers, Rick P G; Zhuang, Ying-Ping; Sutherland, Ian

    2015-12-11

    Manufacturing high-value added biotech biopharmaceutical products (e.g. therapeutic proteins) requires quick-to-develop, GMP-compliant, easy-to-scale and cost effective preparatory chromatography technologies. In this work, we describe the construction and testing of a set of 5-mm inner diameter stainless steel toroidal columns for use on commercially available preparatory scale synchronous J-type counter-current chromatography (CCC) machinery. We used a 20.2m long column with an aqueous two-phase system containing 14% (w/w) PEG1000 and 14% (w/w) potassium phosphate at pH 7, and tested a sample loading of 5% column volume and a mobile phase flow rate of 20ml/min. We then satisfactorily demonstrated the potential for a weekly protein separation and preparation throughput of ca. 11g based on a normal weekly routine for separating a pair of model proteins by making five stacked injections on a single portion of stationary phase with no stripping. Compared to our previous 1.6mm bore PTFE toroidal column, the present columns enlarged the nominal column processing throughput by nearly 10. For an ideal model protein injection modality, we observed a scaling up factor of at least 21. The 2 scales of protein separation and purification steps were realized on the same commercial CCC device.

  2. Simultaneous high-throughput determination of interaction kinetics for drugs and cyclodextrins by high performance affinity chromatography with mass spectrometry detection.

    PubMed

    Wang, Caifen; Wang, Xiaobo; Xu, Xiaonan; Liu, Botao; Xu, Xu; Sun, Lixin; Li, Haiyan; Zhang, Jiwen

    2016-02-25

    The individual determination of the apparent dissociation rate constant (kd,app) using high performance affinity chromatography (HPAC) is a tedious process requiring numerous separate tests and massive data fitting, unable to provide the apparent association rate constant (ka) and equilibrium binding constant (Ka). In this study, a HPAC with mass spectrometry detection (HPAC-MS/MS) was employed to determine the drug-cyclodextrin (CD) interaction kinetics with low sample loading quantity (<10 ng per injection for single compound) and high-throughput yield as twenty drugs determined in one injection. The kd,app measured by HPAC-MS/MS approach were 0.89 ± 0.07, 4.34 ± 0.01, 1.48 ± 0.01 and 7.77 ± 0.04 s(-1) for ketoprofen, trimethoprim, indapamide and acetaminophen, with kd,app for acetaminophen consistent with that from the HPAC method with UV detector in our previous studies. For twenty drugs with diverse structures and chemical properties, good correlationship was found between kd,app measured by single compound analysis method and high-throughput HPAC-MS/MS approach, with the correlation coefficient of 0.987 and the significance F less than 0.001. Comprehensive quantification of ka,app, kd,app and Ka values was further performed based on the measurement of kd,app by peak profiling method and Ka by the peak fitting method. And the investigation of the drug-CD interaction kinetics under different conditions indicated that the column temperature and mobile phase composition significantly affected the determination of ka,app, kd,app and Ka while also dependent on the acidity and basicity of drugs. In summary, the high-throughput HPAC-MS/MS approach has been demonstrated high efficiency in determination of the drug-CD primary interaction kinetic parameter, especially, kd,app, being proven as a novel tool in screening the right CD for the solubilization of the right drug.

  3. Isolation of murine sialoglycoprotein using consecutive chromatography.

    PubMed

    Wilson, D J; Planas, J M

    1991-01-01

    Affinity columns and high performance liquid chromatography were employed consecutively to obtain 89, 65, 46 and 29 kilodalton sialoglycoproteins from mouse erythrocyte ghosts free of the Band 3 protein which traditionally co-purifies with these proteins. The purification scheme involves Concanavalin A, Wheat Germ Agglutinin and/or Limulus lectin Sepharose 4B columns. We have designated these glycophorin-like proteins Sialoglycoproteins 1, 2, 3, and 4, respectively. Sialoglycoprotein 2 can be isolated independently using a Limulus column combination, while Sialoglycoproteins 3 and 4 were isolated separately during high performance liquid chromatography, demonstrating heterogeneity in binding properties between these sialoglycoproteins.

  4. Quantitation of triacylglycerols in edible oils by off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column.

    PubMed

    Wei, Fang; Hu, Na; Lv, Xin; Dong, Xu-Yan; Chen, Hong

    2015-07-24

    In this investigation, off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column has been applied for the identification and quantification of triacylglycerols in edible oils. A novel mixed-mode phenyl-hexyl chromatographic column was employed in this off-line two-dimensional separation system. The phenyl-hexyl column combined the features of traditional C18 and silver-ion columns, which could provide hydrophobic interactions with triacylglycerols under acetonitrile conditions and can offer π-π interactions with triacylglycerols under methanol conditions. When compared with traditional off-line comprehensive two-dimensional liquid chromatography employing two different chromatographic columns (C18 and silver-ion column) and using elution solvents comprised of two phases (reversed-phase/normal-phase) for triacylglycerols separation, the novel off-line comprehensive two-dimensional liquid chromatography using a single column can be achieved by simply altering the mobile phase between acetonitrile and methanol, which exhibited a much higher selectivity for the separation of triacylglycerols with great efficiency and rapid speed. In addition, an approach based on the use of response factor with atmospheric pressure chemical ionization mass spectrometry has been developed for triacylglycerols quantification. Due to the differences between saturated and unsaturated acyl chains, the use of response factors significantly improves the quantitation of triacylglycerols. This two-dimensional liquid chromatography-mass spectrometry system was successfully applied for the profiling of triacylglycerols in soybean oils, peanut oils and lord oils. A total of 68 triacylglycerols including 40 triacylglycerols in soybean oils, 50 triacylglycerols in peanut oils and 44 triacylglycerols in lord oils have been identified and quantified. The liquid chromatography-mass spectrometry data were analyzed

  5. Utilization of different crown ethers impregnated polymeric resin for treatment of low level liquid radioactive waste by column chromatography.

    PubMed

    Attallah, M F; Borai, E H; Hilal, M A; Shehata, F A; Abo-Aly, M M

    2011-11-15

    The main goal of this study was to find a novel impregnated resin as an alternative for the conventional resin (KY-2 and AN-31) used for low and intermediate level liquid radioactive waste treatment. Novel impregnated ion exchangers namely, poly (acrylamide-acrylic acid-acrylonitril)-N,N'-methylenedi-acrylamide-4,4'(5')di-t-butylbenzo 18 crown 6 [P(AM-AA-AN)-DAM/DtBB18C6], poly (acrylamide-acrylic acid-acrylonitril)-N,N'-methylenediacrylamide-dibenzo 18 crown 6 [P(AM-AA-AN)-DAM/DB18C6], and poly (acrylamide-acrylic acid-acrylonitril)-N,N'-methylenediacrylamide-18 crown 6 [P(AM-AA-AN)-DAM/18C6] were prepared and their removal efficiency of some radionuclides was investigated. Preliminary batch experiments were performed in order to study the influence of the different derivatives of 18 crown 6 on the characteristic removal performance. Separation of (134)Cs, (60)Co, (65)Zn and ((152+154))Eu radionuclides from low level liquid radioactive waste was investigated by using column chromatography with P(AM-AA-AN)-DAM/DtBB18C6 and metal salt solutions traced with the corresponding radionuclides. Breakthrough data was obtained in a fixed bed column at room temperature (298K) using different bed heights and flow rates. The breakthrough capacities were found to be 94.7, 83.3, 58.7, 43.1 (mg/g) for (60)Co, (65)Zn, (134)Cs, and ((152+154))Eu, respectively. Pre-concentration and separation of all radionuclides under study have been carried out using different concentration of nitric and/or oxalic acids.

  6. [Determination of free formaldehyde in cosmetics by pre-column derivatization, extraction inhibition and high performance liquid chromatography].

    PubMed

    Lü, Chunhua; Huang, Chaoqun; Chen, Mei; Xie, Wen; Chen, Xiaomei

    2012-12-01

    Pre-column derivatization and inhibition by solvent extraction were applied to determine free formaldehyde in cosmetics by high performance liquid chromatography (HPLC). Due to the rapid decomposition of formaldehyde donors in the derivatization, it is hard to detect the amount of the free formaldehyde in cosmetics. The formaldehyde directly reacted with 2,4-dinitrophenylhydrazine in acetonitrile-phosphate buffer (pH 2) (1:1, v/v) solution for 2 min, then dichloromethane extraction was used to induce the decomposition of formaldehyde donors. The extract was diluted with acetonitrile and then determined by HPLC. The formaldehyde derivative was separated on an Agilent C18 column (250 mm x 4.6 mm, 5 microm) at 30 degrees C with acetonitrile-water (60:40, v/v) as mobile phase at a flow rate of 1.0 mL/min, and detected at the wavelength of 355 nm. The recoveries were from 81% to 106% at the spiked levels of 50, 100, 500, 1 000 microg/g of formaldehyde in shampoo, milk, cream, hand cleaner, toothpaste, nail polish, powder separately, and the relative standard deviations (n = 6) were less than 5.0%. The limit of quantification of the formaldehyde in cosmetics was 50 microg/g. The method has been applied to the determination of free formaldehyde in real samples and the results showed that the release by formaldehyde donors was inhibited. The method has the advantages of simple operation, good accuracy and meets the requirement of determination of free formaldehyde in cosmetics.

  7. Effect of high pH column regeneration on the separation performances in reversed phase chromatography of peptides.

    PubMed

    Gétaz, David; Gencoglu, Mumun; Forrer, Nicola; Morbidelli, Massimo

    2010-05-21

    Caustic regeneration procedures are often used in chromatographic purification processes of peptides and proteins to remove irreversibly bound impurities from the stationary phase. Silica-based materials are the most commonly used materials in reversed phase chromatography of peptides. Their limited chemical stability at high pH can be, however, problematic when high pH column regeneration (i.e. cleaning in place) is required. The effect of cleaning in place on the surface chemistry of the stationary phase has been investigated using the Tanaka test. It has been shown that the high pH treatment does not significantly affect the hydrophobicity of the material, but it strongly increases its silanol activity. A representative peptide purification process has been used to investigate the impact of cleaning in place on the separation performance. It has been shown that the caustic regeneration increases the peptide retention at high pH (pH 6.5), due to the interactions between the peptide and the negatively charged silanol groups. These unwanted interactions reduce the separation performances by decreasing the selectivity between the late eluting impurities and the main peptide. However, it has been shown that the effect of the silanol groups on the peptide adsorption and on the separation performance can be minimized by carrying out the purification process at low pH (pH approximately 2). In this case, the silanol groups are protonated and their electrostatic interactions with the positively charged analyte (i.e. peptides) are suppressed. In these conditions, the peptide adsorption and the impurity selectivity is not changing upon high pH column regeneration and the separation performance is not affected.

  8. Effect of pressure pulses at the interface valve on the stability of second dimension columns in online comprehensive two-dimensional liquid chromatography.

    PubMed

    Talus, Eric S; Witt, Klaus E; Stoll, Dwight R

    2015-01-23

    Users of online comprehensive two-dimensional liquid chromatography (LCxLC) frequently acknowledge that the mechanical instability of HPLC columns installed in these systems, particularly in the second dimension, is a significant impediment to its use. Such instability is not surprising given the strenuous operating environment to which these columns are subjected, including the large number (thousands per day) of fast and large pressure pulses resulting from interface valve switches (on the timescale of tens of milliseconds) associated with very fast second dimension separations. There appear to be no published reports of systematic studies of the relationship between second dimension column lifetime and any of these variables. In this study we focused on the relationship between the lifetimes of commercially available columns and the pressure pulses observed at the inlet of the second dimension column that occur during the switching of the valve that interfaces the two dimensions of a LCxLC system. We find that the magnitude of the pressure drop at the inlet of the second dimension column during the valve switch, which may vary between 10 and 95% of the column inlet pressure, is dependent on valve switching speed and design, and has a dramatic impact on column lifetime. In the worst case, columns fail within the first few hours of use in an LCxLC system. In the best case, using a valve that exhibits much smaller pressure pulses, the same columns exhibit much improved lifetimes and have been used continuously under LCxLC conditions for several days with no degradation in performance. This result represents a first step in understanding the factors that affect second dimension column lifetime, and will significantly improve the usability of the LCxLC technique in general.

  9. Profiling of triacylglycerols in plant oils by high-performance liquid chromatography-atmosphere pressure chemical ionization mass spectrometry using a novel mixed-mode column.

    PubMed

    Hu, Na; Wei, Fang; Lv, Xin; Wu, Lin; Dong, Xu-Yan; Chen, Hong

    2014-12-01

    In this investigation, a rapid and high-throughput method for profiling of TAGs in plant oils by liquid chromatography using a single column coupled with atmospheric pressure chemical ionization (APCI) mass spectrometry was reported. A novel mixed-mode phenyl-hexyl chromatographic column was employed in this separation system. The phenyl-hexyl column could provide hydrophobic interactions as well as π-π interactions. Compared with two traditionally columns used in TAG separation - the C18 column and silver-ion column, this column exhibited much higher selectivity for the separation of TAGs with great efficiency and rapid speed. By comparison with a novel mix-mode column (Ag-HiSep OTS column), which can also provide both hydrophobic interactions as well as π-π interactions for the separation of TAGs, phenyl-hexyl column exhibited excellent stability. LC method using phenyl-hexyl column coupled with APCI-MS was successfully applied for the profiling of TAGs in soybean oils, peanut oils, corn oils, and sesame oils. 29 TAGs in peanut oils, 22 TAGs in soybean oils, 19 TAGs in corn oils, and 19 TAGs in sesame oils were determined and quantified. The LC-MS data was analyzed by barcodes and principal component analysis (PCA). The resulting barcodes constitute a simple tool to display differences between different plant oils. Results of PCA also enabled a clear identification of different plant oils. This method provided an efficient and convenient chromatographic technology for the fast characterization and quantification of complex TAGs in plant oils at high selectivity. It has great potential as a routine analytical method for analysis of edible oil quality and authenticity control.

  10. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: a review on instrumentation and chemistries.

    PubMed

    Zacharis, Constantinos K; Tzanavaras, Paraskevas D

    2013-10-10

    Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular "chemistries" that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables.

  11. Evaluation and application of static headspace-multicapillary column-gas chromatography-ion mobility spectrometry for complex sample analysis.

    PubMed

    Denawaka, Chamila J; Fowlis, Ian A; Dean, John R

    2014-04-18

    An evaluation of static headspace-multicapillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS) has been undertaken to assess its applicability for the determination of 32 volatile compounds (VCs). The key experimental variables of sample incubation time and temperature have been evaluated alongside the MCC-GC variables of column polarity, syringe temperature, injection temperature, injection volume, column temperature and carrier gas flow rate coupled with the IMS variables of temperature and drift gas flow rate. This evaluation resulted in six sets of experimental variables being required to separate the 32 VCs. The optimum experimental variables for SHS-MCC-GC-IMS, the retention time and drift time operating parameters were determined; to normalise the operating parameters, the relative drift time and normalised reduced ion mobility for each VC were determined. In addition, a full theoretical explanation is provided on the formation of the monomer, dimer and trimer of a VC. The optimum operating condition for each VC calibration data was obtained alongside limit of detection (LOD) and limit of quantitation (LOQ) values. Typical detection limits ranged from 0.1ng bis(methylthio)methane, ethylbutanoate and (E)-2-nonenal to 472ng isovaleric acid with correlation coefficient (R(2)) data ranging from 0.9793 (for the dimer of octanal) through to 0.9990 (for isobutyric acid). Finally, the developed protocols were applied to the analysis of malodour in sock samples. Initial work involved spiking an inert matrix and sock samples with appropriate concentrations of eight VCs. The average recovery from the inert matrix was 101±18% (n=8), while recoveries from the sock samples were lower, that is, 54±30% (n=8) for sock type 1 and 78±24% (n=6) for sock type 2. Finally, SHS-MCC-GC-IMS was applied to sock malodour in a field trial based on 11 volunteers (mixed gender) over a 3-week period. By applying the SHS-MCC-GC-IMS database, four VCs were

  12. Tracing novel hemostatic compounds from heating products of total flavonoids in Flos Sophorae by spectrum-effect relationships and column chromatography.

    PubMed

    Chen, Yeqing; Yu, Hongli; Wu, Hao; Pan, Yaozong; Wang, Kuilong; Liu, Liping; Jin, Yangping; Zhang, Chenchao

    2015-05-01

    Flos Sophorae and its processed product have been clinically used to treat hemorrhage. In this study, the total ion chromatographic fingerprints of the heating products of total flavonoids in Flos Sophorae were established by high-performance liquid chromatography with tandem mass spectrometry and the hemostatic activities were studied by hemostatic screening tests in vivo. The spectrum-effect relationships between fingerprints and hemostatic activities were investigated using canonical correlation analysis to trace the peaks responsible for the hemostatic effects. The predicted active peaks in fingerprints were isolated by column chromatography and their structures were identified by NMR spectroscopy and mass spectrometry. The hemostatic activities of them were verified by platelet aggregation and procoagulation assays in vitro. Canonical correlation analysis results showed that peak 8 and peak 11 were correlated most closely, thus probably being the main hemostatic compounds. Through column chromatography separation, peak 8 (compound I) and peak 11 (compound II) were obtained with purities of 95.61 and 93.38%, respectively, and were discovered new hemostatic compounds named as huaicarbon A (I) and huaicarbon B (II), respectively. This study provides a universal model to trace the active compounds of other herbs which have bioactivity enhancement after processing by spectrum-effect relationships and column chromatography.

  13. Facile fabrication and instant application of miniaturized antibody-decorated affinity columns for higher-order structure and functional characterization of TRIM21 epitope peptides.

    PubMed

    Al-Majdoub, M; Opuni, K F M; Koy, C; Glocker, M O

    2013-11-05

    Both epitope excision and epitope extraction methods, combined with mass spectrometry, generate precise informations on binding surfaces of full-length proteins, identifying sequential (linear) or assembled (conformational) epitopes, respectively. Here, we describe the one-step fabrication and application of affinity columns using reversibly immobilized antibodies with highest flexibility with respect to antibody sources and lowest sample amount requirements (fmol range). Depending on the antibody source, we made use of protein G- or protein A-coated resins as support materials. These materials are packed in pipet tips and in combination with a programmable multichannel pipet form a highly efficient epitope mapping system. In addition to epitope identification, the influence of epitope structure modifications on antibody binding specificities could be studied in detail with synthetic peptides. Elution of epitope peptides was optimized such that mass spectrometric analysis was feasible after a single desalting step. Epitope peptides were identified by accurate molecular mass determinations or by partial amino acid sequence analysis. In addition, charge state comparison or ion mobility analysis of eluted epitope peptides enabled investigation of higher-order structures. The epitope peptide of the TRIM21 (TRIM: tripartite motif) autoantigen that is recognized by a polyclonal antibody was determined as assembling an "L-E-Q-L" motif on an α-helix. Secondary structure determination by circular dichroism spectroscopy and structure modeling are in accordance with the mass spectrometric results and the antigenic behavior of the 17-mer epitope peptide variants from the full-length autoantigen.

  14. Direct determination of acylcarnitines in amniotic fluid by column-switching liquid chromatography with electrospray tandem mass spectrometry.

    PubMed

    Cho, Sung-Hee; Lee, Jeongae; Lee, Won-Yong; Chung, Bong Chul

    2006-01-01

    A direct, simple, and simultaneous determination of acylcarnitines in amniotic fluid was developed using column-switching liquid chromatography/tandem mass spectrometry (LC/MS/MS). The analytes can be assayed within 20 min without any sample preparation process, and we monitored separated acylcarnitines with positive electrospray ionization (ESI)-MS/MS. The calibration ranges of acylcarnitines were 1 to 100 nmol/L. The linearity of the method was 0.992 to 0.999, and the limits of detection at a signal-to-noise ratio of 3 were 1 nmol/L. The coefficients of variation were in the range of 5.2 to 13.3% for within-day variation and 6.7 to 11.9% for day-to-day, respectively. We detected acylcarnitines in the amniotic fluid of 22 women in the early stages of their pregnancies in the range of 2.2 to 17.2 nmol/L. The proposed method could be applied to diagnosis, monitoring, and biomedical investigations of inborn errors of the organic acid and fatty acid metabolism of the embryo.

  15. A soil-column gas chromatography (SCGC) approach to explore the thermal desorption behavior of hydrocarbons from soils.

    PubMed

    Yu, Ying; Liu, Liang; Shao, Ziying; Ju, Tianyu; Sun, Bing; Benadda, Belkacem

    2016-01-01

    A soil-column gas chromatography approach was developed to simulate the mass transfer process of hydrocarbons between gas and soil during thermally enhanced soil vapor extraction (T-SVE). Four kinds of hydrocarbons-methylbenzene, n-hexane, n-decane, and n-tetradecane-were flowed by nitrogen gas. The retention factor k' and the tailing factor T f were calculated to reflect the desorption velocities of fast and slow desorption fractions, respectively. The results clearly indicated two different mechanisms on the thermal desorption behaviors of fast and slow desorption fractions. The desorption velocity of fast desorption fraction was an exponential function of the reciprocal of soil absolute temperature and inversely correlated with hydrocarbon's boiling point, whereas the desorption velocity of slow desorption fraction was an inverse proportional function of soil absolute temperature, and inversely proportional to the log K OW value of the hydrocarbons. The higher activation energy of adsorption was found on loamy soil with higher organic content. The increase of carrier gas flow rate led to a reduction in the apparent activation energy of adsorption of slow desorption fraction, and thus desorption efficiency was significantly enhanced. The obtained results are of practical interest for the design of high-efficiency T-SVE system and may be used to predict the remediation time.

  16. Versatile, sensitive liquid chromatography mass spectrometry – Implementation of 10 μm OT columns suitable for small molecules, peptides and proteins

    PubMed Central

    Vehus, T.; Roberg-Larsen, H.; Waaler, J.; Aslaksen, S.; Krauss, S.; Wilson, S. R.; Lundanes, E.

    2016-01-01

    We have designed a versatile and sensitive liquid chromatographic (LC) system, featuring a monolithic trap column and a very narrow (10 μm ID) fused silica open tubular liquid chromatography (OTLC) separation column functionalized with C18-groups, for separating a wide range of molecules (from small metabolites to intact proteins). Compared to today’s capillary/nanoLC approaches, our system provides significantly enhanced sensitivity (up to several orders) with matching or improved separation efficiency, and highly repeatable chromatographic performance. The chemical properties of the trap column and the analytical column were fine-tuned to obtain practical sample loading capacities (above 2 μg), an earlier bottleneck of OTLC. Using the OTLC system (combined with Orbitrap mass spectrometry), we could perform targeted metabolomics of sub-μg amounts of exosomes with 25 attogram detection limit of a breast cancer-related hydroxylated cholesterol. With the same set-up, sensitive bottom-up proteomics (targeted and untargeted) was possible, and high-resolving intact protein analysis. In contrast to state-of-the-art packed columns, our platform performs chromatography with very little dilution and is “fit-for-all”, well suited for comprehensive analysis of limited samples, and has potential as a tool for challenges in diagnostics. PMID:27897190

  17. Pressure, temperature and density drops along supercritical fluid chromatography columns. I. Experimental results for neat carbon dioxide and columns packed with 3- and 5-micron particles.

    PubMed

    Poe, Donald P; Veit, Devon; Ranger, Megan; Kaczmarski, Krzysztof; Tarafder, Abhijit; Guiochon, Georges

    2012-08-10

    The pressure drop and temperature drop on columns packed with 3- and 5-micron particles were measured using neat CO(2) at a flow rate of 5 mL/min, at temperatures from 20°C to 100°C, and outlet pressures from 80 to 300 bar. The density drop was calculated based on the temperature and pressure at the column inlet and outlet. The columns were suspended in a circulating air bath either bare or covered with foam insulation. The results show that the pressure drop depends on the outlet pressure, the operating temperature, and the thermal environment. A temperature drop was observed for all conditions studied. The temperature drop was relatively small (less than 3°C) for combinations of low temperature and high pressure. Larger temperature drops and density drops occurred at higher temperatures and low to moderate pressures. Covering the column with thermal insulation resulted in larger temperature drops and corresponding smaller density drops. At 20°C the temperature drop was never more than a few degrees. The largest temperature drops occurred for both columns when insulated at 80°C and 80 bar, reaching a maximum value of 21°C for the 5-micron column, and 26°C for the 3-micron column. For an adiabatic column, the temperature drop depends on the pressure drop, the thermal expansion coefficient, and the density and the heat capacity of the mobile phase fluid, and can be described by a simple mathematical relationship. For a fixed operating temperature and outlet pressure, the temperature drop increases monotonically with the pressure drop.

  18. Optimization of post-column reactor radius in capillary high performance liquid chromatography Effect of chromatographic column diameter and particle diameter.

    PubMed

    Xu, Hongjuan; Weber, Stephen G

    2006-04-28

    A post-column reactor consisting of a simple open tube (Capillary Taylor Reactor) affects the performance of a capillary LC in two ways: stealing pressure from the column and adding band spreading. The former is a problem for very small radius reactors, while the latter shows itself for large reactor diameters. We derived an equation that defines the observed number of theoretical plates (N(obs)) taking into account the two effects stated above. Making some assumptions and asserting certain conditions led to a final equation with a limited number of variables, namely chromatographic column radius, reactor radius and chromatographic particle diameter. The assumptions and conditions are that the van Deemter equation applies, the mass transfer limitation is for intraparticle diffusion in spherical particles, the velocity is at the optimum, the analyte's retention factor, k', is zero, the post-column reactor is only long enough to allow complete mixing of reagents and analytes and the maximum operating pressure of the pumping system is used. Optimal ranges of the reactor radius (a(r)) are obtained by comparing the number of observed theoretical plates (and theoretical plates per time) with and without a reactor. Results show that the acceptable reactor radii depend on column diameter, particle diameter, and maximum available pressure. Optimal ranges of a(r) become narrower as column diameter increases, particle diameter decreases or the maximum pressure is decreased. When the available pressure is 4000 psi, a Capillary Taylor Reactor with 12 microm radius is suitable for all columns smaller than 150 microm (radius) packed with 2-5 microm particles. For 1 microm packing particles, only columns smaller than 42.5 microm (radius) can be used and the reactor radius needs to be 5 microm.

  19. Improved Thermal Modulator for Gas Chromatography

    NASA Technical Reports Server (NTRS)

    Hasselbrink, Ernest Frederick, Jr.; Hunt, Patrick J.; Sacks, Richard D.

    2008-01-01

    An improved thermal modulator has been invented for use in a variant of gas chromatography (GC). The variant in question denoted as two-dimensional gas chromatography (2DGC) or GC-GC involves the use of three series-connected chromatographic columns, in the form of capillary tubes coated interiorly with suitable stationary phases (compounds for which different analytes exhibit different degrees of affinity). The two end columns are relatively long and are used as standard GC columns. The thermal modulator includes the middle column, which is relatively short and is not used as a standard GC column: instead, its temperature is modulated to affect timed adsorption and desorption of analyte gases between the two end columns in accordance with a 2DGC protocol.

  20. Analysis of Multi-Site Drug-Protein Interactions by High-Performance Affinity Chromatography: Binding by Glimepiride to Normal or Glycated Human Serum Albumin

    PubMed Central

    Matsuda, Ryan; Li, Zhao; Zheng, Xiwei; Hage, David S.

    2015-01-01

    High-performance affinity chromatography (HPAC) was used in a variety of formats to examine multi-site interactions between glimepiride, a third-generation sulfonylurea drug, and normal or in vitro glycated forms of the transport protein human serum albumin (HSA). Frontal analysis revealed that glimepiride interacts with normal HSA and glycated HSA at a group of high affinity sites (association equilibrium constant, or Ka, 9.2–11.8 × 105 M−1 at pH 7.4 and 37°C) and a group of lower affinity regions (Ka, 5.9–16.2 × 103 M−1). Zonal elution competition studies were designed and carried out in both normal- and reversed-role formats to investigate the binding by this drug at specific sites. These experiments indicated that glimepiride was interacting at both Sudlow sites I and II. Allosteric effects were also noted with R-warfarin at Sudlow site I and with tamoxifen at the tamoxifen site on HSA. The binding at Sudlow site I had a 2.1- to 2.3-fold increase in affinity in going from normal HSA to the glycated samples of HSA. There was no significant change in the affinity for glimepiride at Sudlow site II in going from normal HSA to a moderately glycated sample of HSA, but a slight decrease in affinity was seen in going to a more highly glycated HSA sample. These results demonstrated how various HPAC-based methods can be used to profile and characterize multi-site binding by a drug such as glimepiride to a protein and its modified forms. The information obtained from this study should be useful in providing a better understanding of how drug-protein binding may be affected by glycation and of how separation and analysis methods based on HPAC can be employed to study systems with complex interactions or that involve modified proteins. PMID:26189669

  1. Affinity chromatography of GroEL chaperonin based on denatured proteins: role of electrostatic interactions in regulation of GroEL affinity for protein substrates.

    PubMed

    Marchenko, N Iu; Marchenkov, V V; Kaĭsheva, A L; Kashparov, I A; Kotova, N V; Kaliman, P A; Semisotnov, G V

    2006-12-01

    The chaperonin GroEL of the heat shock protein family from Escherichia coli cells can bind various polypeptides lacking rigid tertiary structure and thus prevent their nonspecific association and provide for acquisition of native conformation. In the present work we studied the interaction of GroEL with six denatured proteins (alpha-lactalbumin, ribonuclease A, egg lysozyme in the presence of dithiothreitol, pepsin, beta-casein, and apocytochrome c) possessing negative or positive total charge at neutral pH values and different in hydrophobicity (affinity for a hydrophobic probe ANS). To prevent the influence of nonspecific association of non-native proteins on their interaction with GroEL and make easier the recording of the complexing, the proteins were covalently attached to BrCN-activated Sepharose. At low ionic strength (lower than 60 mM), tight binding of the negatively charged denatured proteins with GroEL (which is also negatively charged) needed relatively low concentrations (approximately 10 mM) of bivalent cations Mg2+ or Ca2+. At the high ionic strength (approximately 600 mM), a tight complex was produced also in the absence of bivalent cations. In contrast, positively charged denatured proteins tightly interacted with GroEL irrespectively of the presence of bivalent cations and ionic strength of the solution (from 20 to 600 mM). These features of GroEL interaction with positively and negatively charged denatured proteins were confirmed by polarized fluorescence (fluorescence anisotropy). The findings suggest that the affinity of GroEL for denatured proteins can be determined by the balance of hydrophobic and electrostatic interactions.

  2. Gas Chromatography.

    ERIC Educational Resources Information Center

    Karasek, Francis W.; And Others

    1984-01-01

    This review covers fundamental developments in gas chromatography during 1982 and 1983. Literature is considered under these headings: columns; liguid phases; solid supports; sorption processes and solvents; open tubular column gas chromatography; instrumentation; high-resolution columns and applications; other techniques; qualitative and…

  3. A strategy for identification and structural characterization of compounds from Gardenia jasminoides by integrating macroporous resin column chromatography and liquid chromatography-tandem mass spectrometry combined with ion-mobility spectrometry.

    PubMed

    Wang, Lu; Liu, Shu; Zhang, Xueju; Xing, Junpeng; Liu, Zhiqiang; Song, Fengrui

    2016-06-24

    In this paper, an analysis strategy integrating macroporous resin (AB-8) column chromatography and high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) combined with ion mobility spectrometry (IMS) was proposed and applied for identification and structural characterization of compounds from the fruits of Gardenia jasminoides. The extracts of G. jasminoides were separated by AB-8 resin column chromatography combined with reversed phase liquid chromatography (C18 column) and detected by electrospray ionization tandem mass spectrometry. Additionally, ion mobility spectrometry (IMS) was employed as a supplementary separation technique to discover previously undetected isomers from the fruits of G. jasminoides. A total of 71 compounds, including iridoids, flavonoids, triterpenes, monoterpenoids, carotenoids and phenolic acids were identified by the characteristic high resolution mass spectrometry and the ESI-MS/MS fragmentations. In conclusion, the IMS-MS technique achieved the separation of isomers in crocin-3 and crocin-4 according to their acquired mobility drift times differing from classical analysis by mass spectrometry. The proposed strategy can be used as a highly sensitive and efficient procedure for identification and separation isomeric components in extracts of herbal medicines.

  4. A microfluidic device for preparing next generation DNA sequencing libraries and for automating other laboratory protocols that require one or more column chromatography steps.

    PubMed

    Tan, Swee Jin; Phan, Huan; Gerry, Benjamin Michael; Kuhn, Alexandre; Hong, Lewis Zuocheng; Min Ong, Yao; Poon, Polly Suk Yean; Unger, Marc Alexander; Jones, Robert C; Quake, Stephen R; Burkholder, William F

    2013-01-01

    Library preparation for next-generation DNA sequencing (NGS) remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation.

  5. Synthesis of sulfonamide- and sulfonyl-phenylboronic acid-modified silica phases for boronate affinity chromatography at physiological pH.

    PubMed

    Li, Xiaobao; Pennington, Justin; Stobaugh, John F; Schöneich, Christian

    2008-01-15

    Two new types of boronate affinity solid phases were synthesized and characterized. The materials were prepared by silylation of porous silica gel with monochlorosilane derivatives containing synthetic sulfonyl- and sulfonamide-substituted phenylboronic acids. The new solid phases were evaluated for boronate affinity chromatography with aryl and alkyl cis-diol compounds and were found to be suitable for the retention of cis-diols under acidic conditions. Significant correlations between the retention factor (K) and the pH of the mobile phase demonstrate that the binding of cis-diols to the solid phases is best rationalized by chelation. Based on the lower pKa, caused by the electron-withdrawing effects of the sulfonyl and sulfonamide groups, these media display an enhanced affinity for cis-diols as compared with unsubstituted phenylboronic acid. Using isocratic elution, a mixture of various biologically relevant l-tyrosines, l-DOPA, and several catecholamines were resolved with a mobile phase composed of 0.05M phosphate buffer (pH 5.5). Mono-, di-, and triphosphates of adenosine were also separated at pH 6.0. Hence, the new boronate solid phase offers efficient affinity separation and purification of cis-diol-containing molecules under rather mild pH conditions.

  6. Chromatography

    MedlinePlus

    Chromatography is a way of separating two or more chemical compounds. Chemical compounds are chemicals that are ... of chemical compound. There are different kinds of chromatography. These include gas, high pressure liquid, or ion ...

  7. Isolation of a Trypanosoma cruzi antigen by affinity chromatography with a monoclonal antibody. Preliminary evaluation of its possible applications in serological tests.

    PubMed Central

    Carbonetto, C H; Malchiodi, E L; Chiaramonte, M; Durante de Isola, E; Fossati, C A; Margni, R A

    1990-01-01

    By affinity chromatography with a monoclonal antibody (163B6), obtained in our laboratory, we have isolated a T. cruzi antigen which could be useful for differential diagnosis of Chagas' disease from leishmaniasis. This antigen, a 52-kD protein, reacted with all sera from Chagas' disease patients tested but not with sera from patients with leishmania, in ELISA. The 52-kD antigen is widely distributed in the Trypanosoma genus since the 163B6 monoclonal antibody reacts with T. rangeli and 8 strains and a clone of T. cruzi epimastigotes. Images Fig. 1 Fig. 2 PMID:2119921

  8. Determination of trans-10-hydroxy-2-decenoic acid content in pure royal jelly and royal jelly products by column liquid chromatography.

    PubMed

    Genç, M; Aslan, A

    1999-04-16

    In this research, several royal jellies and commercial products containing royal jelly were analysed for their trans-10-hydroxy-2-decenoic acid (10-HDA) content by using a column liquid chromatography technique. Ten samples claimed to be pure royal jelly, containing 10-HDA between 0.75 and 2.54%. Seven samples claimed to contain royal jelly as an ingredient which ranged from non-detectable to 0.054%. The technique was found to be rapid with high recovery.

  9. Caprylic acid-induced impurity precipitation from protein A capture column elution pool to enable a two-chromatography-step process for monoclonal antibody purification.

    PubMed

    Zheng, Ji; Wang, Lu; Twarowska, Barbara; Laino, Sarah; Sparks, Colleen; Smith, Timothy; Russell, Reb; Wang, Michelle

    2015-01-01

    This article presents the use of caprylic acid (CA) to precipitate impurities from the protein A capture column elution pool for the purification of monoclonal antibodies (mAbs) with the objective of developing a two chromatography step antibody purification process. A CA-induced impurity precipitation in the protein A column elution pool was evaluated as an alternative method to polishing chromatography techniques for use in the purification of mAbs. Parameters including pH, CA concentrations, mixing time, mAb concentrations, buffer systems, and incubation temperatures were evaluated on their impacts on the impurity removal, high-molecular weight (HMW) formation and precipitation step yield. Both pH and CA concentration, but not mAb concentrations and buffer systems, are key parameters that can affect host-cell proteins (HCPs) clearance, HMW species, and yield. CA precipitation removes HCPs and some HMW species to the acceptable levels under the optimal conditions. The CA precipitation process is robust at 15-25°C. For all five mAbs tested in this study, the optimal CA concentration range is 0.5-1.0%, while the pH range is from 5.0 to 6.0. A purification process using two chromatography steps (protein A capture column and ion exchange polishing column) in combination with CA-based impurity precipitation step can be used as a robust downstream process for mAb molecules with a broad range of isoelectric points. Residual CA can be effectively removed by the subsequent polishing cation exchange chromatography.

  10. Sequential injection chromatography with post-column reaction/derivatization for the determination of transition metal cations in natural water samples.

    PubMed

    Horstkotte, Burkhard; Jarošová, Patrícia; Chocholouš, Petr; Sklenářová, Hana; Solich, Petr

    2015-05-01

    In this work, the applicability of Sequential Injection Chromatography for the determination of transition metals in water is evaluated for the separation of copper(II), zinc(II), and iron(II) cations. Separations were performed using a Dionex IonPAC™ guard column (50mm×2mm i.d., 9 µm). Mobile phase composition and post-column reaction were optimized by modified SIMPLEX method with subsequent study of the concentration of each component. The mobile phase consisted of 2,6-pyridinedicarboxylic acid as analyte-selective compound, sodium sulfate, and formic acid/sodium formate buffer. Post-column addition of 4-(2-pyridylazo)resorcinol was carried out for spectrophotometric detection of the analytes׳ complexes at 530nm. Approaches to achieve higher robustness, baseline stability, and detection sensitivity by on-column stacking of the analytes and initial gradient implementation as well as air-cushion pressure damping for post-column reagent addition were studied. The method allowed the rapid separation of copper(II), zinc(II), and iron(II) within 6.5min including pump refilling and aspiration of sample and 1mmol HNO3 for analyte stacking on the separation column. High sensitivity was achieved applying an injection volume of up to 90µL. A signal repeatability of<2% RSD of peak height was found. Analyte recovery evaluated by spiking of different natural water samples was well suited for routine analysis with sub-micromolar limits of detection.

  11. Development and characterization of a chitosan-supported immunoaffinity chromatography column for the selective extraction of methandrostenolone from food and feed samples.

    PubMed

    Wang, Yun; Xu, Yan; Zhang, Xun; Wang, Enlan; Dong, Ying

    2011-10-01

    The development of a chitosan-supported immunoaffinity chromatography (IAC) column and its application to the selective extraction of methandrostenolone (MA) from food and feed samples were described in this paper. Using hybridoma technique, a monoclonal antibody (mAb) against MA was produced. The IAC column was prepared by coupling the produced antibody with crosslinked chitosan. Scanning electron microscopy and IR spectroscopy was used to characterize the chitosan crosslinking and antibody coupling. 2% and 90% methanol were respectively selected as loading and eluting solution by optimization. The maximum capacity of the column for MA was 1790ng/mL gel. The extraction recoveries of the column for MA at three different spiked concentrations ranged from 83.7 to 98.5%. After 2 cycles of usage, the column capacity and extraction recovery still remained 84.6% and 80.5%. To further verify the effect of matrix on the IAC cleanup, MA-fortified food and feed samples were extracted using the prepared IAC column, and MA recovery rates were found to be 86.2% and 70.4%, respectively.

  12. Silica-based monolithic columns with mixed-mode reversed-phase/weak anion-exchange selectivity principle for high-performance liquid chromatography.

    PubMed

    Nogueira, Raquel; Lubda, Dieter; Leitner, Alexander; Bicker, Wolfgang; Maier, Norbert M; Lämmerhofer, Michael; Lindner, Wolfgang

    2006-05-01

    This article describes the synthesis, chromatographic characterization, and performance evaluation of analytical (100 x 4.6 mm id) and semipreparative (100 x 10 mm id) monolithic silica columns with mixed-mode RP/weak anion-exchange (RP/WAX) surface modification. The monolithic RP/WAX columns were obtained by immobilization of N-(10-undecenoyl)-3-aminoquinuclidine onto thiol-modified monolithic silica columns (Chromolith) by a radical addition reaction. Their chromatographic characterization by Engelhardt and Tanaka tests revealed slightly lower hydrophobic selectivities than C-8 phases, as well as higher polarity and also improved shape selectivity than RP-18e silica rods. The surface modification enabled separation by both RP and anion-exchange chromatography principles, and thus showed complementary selectivities to the RP-18e monoliths. The mixed-mode monoliths have been tested for the separation of peptides and turned out to be particularly useful for hydrophilic acidic peptides, which are usually insufficiently retained on RP-18e monolithic columns. Compared to a corresponding particulate RP/WAX column (5 microm, 10 nm pore diameter), the analytical RP/WAX monolith caused lower system pressure drops and showed, as expected, higher efficiency (e.g. by a factor of about 2.5 lower C-term for a tetrapeptide). The upscaling from the analytical to semipreparative column dimension was also successful.

  13. Purification of quercetin-3-O-sophoroside and isoquercitrin from Poacynum hendersonii leaves using macroporous resins followed by Sephadex LH-20 column chromatography.

    PubMed

    Li, Hongjuan; Liu, Ying; Yi, Yuetao; Miao, Qin; Liu, Sujing; Zhao, Feng; Cong, Wei; Wang, Chunhua; Xia, Chuanhai

    2017-03-24

    In China, Poacynum hendersonii is frequently used as a substitute for Apoacynum venetum L (Luobuma), which is a famous traditional Chinese medicine. Quercetin-3-O-sophoroside and isoquercitrin are two major flavonoids in Poacynum hendersonii leaves. In this work, a suitable method was established for the large-scale preparation of quercetin-3-O-sophoroside (QOS) and isoquercitrin (ISO) from Poacynum hendersonii leaves using macroporous resin combined with Sephadex LH-20 column chromatography. The adsorption/desorption capacities and desorption ratios of six macroporous resins were evaluated using static experiments. The HPD-300 resin had the best adsorption performance because it had the largest surface area, and was selected for further study. Compared with pseudo-first-order and intraparticle diffusion kinetics models, the pseudo-second-order model could better fit the adsorption kinetics of both QOS and ISO on the HPD-300 resin. In addition, the adsorption isotherms of the two compounds on the HPD-300 resin were fitted well to the Langmuir model. Under optimal conditions, the purities of QOS and ISO in the product were increased from 2.16% and 1.26% to 21.34% and 10.70% with recovery yields of 82.1% and 77.3%, respectively. Subsequently, Sephadex LH-20 column chromatography was employed for improving the purities of the two compounds. After separation by Sephadex LH-20 column chromatography, the purities of QOS and ISO achieved 93.5% and 95.6%, respectively.

  14. Capillary ion chromatography with on-column focusing for ultra-trace analysis of methanesulfonate and inorganic anions in limited volume Antarctic ice core samples.

    PubMed

    Rodriguez, Estrella Sanz; Poynter, Sam; Curran, Mark; Haddad, Paul R; Shellie, Robert A; Nesterenko, Pavel N; Paull, Brett

    2015-08-28

    Preservation of ionic species within Antarctic ice yields a unique proxy record of the Earth's climate history. Studies have been focused until now on two proxies: the ionic components of sea salt aerosol and methanesulfonic acid. Measurement of the all of the major ionic species in ice core samples is typically carried out by ion chromatography. Former methods, whilst providing suitable detection limits, have been based upon off-column preconcentration techniques, requiring larger sample volumes, with potential for sample contamination and/or carryover. Here, a new capillary ion chromatography based analytical method has been developed for quantitative analysis of limited volume Antarctic ice core samples. The developed analytical protocol applies capillary ion chromatography (with suppressed conductivity detection) and direct on-column sample injection and focusing, thus eliminating the requirement for off-column sample preconcentration. This limits the total sample volume needed to 300μL per analysis, allowing for triplicate sample analysis with <1mL of sample. This new approach provides a reliable and robust analytical method for the simultaneous determination of organic and inorganic anions, including fluoride, methanesulfonate, chloride, sulfate and nitrate anions. Application to composite ice-core samples is demonstrated, with coupling of the capillary ion chromatograph to high resolution mass spectrometry used to confirm the presence and purity of the observed methanesulfonate peak.

  15. The use of phospholipid modified column for the determination of lipophilic properties in high performance liquid chromatography.

    PubMed

    Godard, Tal; Grushka, Eli

    2011-03-04

    A new chromatographic stationary phase obtained by coating a reversed phase amide column with phosphatidylcholine based liposomes solution to yield a phospholipid modified column (PLM). The modification is achieved by the dynamic coating method which recycles the coating solution through the column in a closed loop for a period of 24 h. The chromatographic properties of the new column have changed significantly as compared to the original amide column due to the phospholipid coating. A good correlation was observed between n-octanol/water logP values and the logarithm of the retention factor obtained on the PLM column for a large number of solutes. In addition the PLM column was characterized using the linear solvation energy relationship (LSER). The values of the LSER system constants for the PLM column were calculated and were found to be very close to those of the n-octanol/water extraction system thus suggesting that the PLM column can be used for the estimation of n-octanol/water partition coefficient and serve as a possible alternative to the shake-flask method for lipophilicity determination. In addition, the results suggest that the PLM column can provide an alternative to other phospholipid-based column such as the IAM and the DPC columns.

  16. [Application of spiral disk column in high-speed counter-current chromatography for peptide and protein separation].

    PubMed

    Hu, Guanghui; Cao, Xueli

    2009-04-01

    In order to improve the stationary phase retention of polar solvent systems and aqueous two-phase systems (ATPSs), we designed a multiple spiral disk assembly for type-J high-speed counter-current chromatography (HSCCC). The stationary phase retention was studied under different elution modes by using two solvent systems that contained 1-butanol-acetic acid-water (4:1:5, V/V/V) and polyethylene glycol (PEG) 1000-K2HPO4-water (12.5:12.5:75, W/W/W). The best retention was obtained in L-I-T, U-O-H, L-I-H three modes by pumping lower mobile phase from inner terminal (I) to outer terminal (O), and upper mobile phase from outer terminal (O) to inner terminal (I) at a relatively high flow rate. Meanwhile, the relationship between retention percentage of the stationary phase (Sf) and various parameters such as flow-rate (F), rotation speed (w) and column temperature (T) was also studied. Sf increased with the increase of w and decreased with the increase of F. Regression analysis showed a linear relationship between Sf and F1/2/w. The influence of T on Sf was not obvious between 20 degrees C and 40 degrees C, lower temperature than 20 degrees C was not suitable for viscous ATPSs. Acceptable resolutions were achieved when it was applied for the separation of dipeptides including Leu-Tyr and Val-Tyr by using 1-butanol-acetic acid-water (4:1:5, V/V/V) solvent system. The proteins including cytochrome C and myoglobin, lysozyme and myoglobin, and fresh chicken egg-white proteins were well separated by 12.5% PEG1000-12.5% K2HPO4-75% water (pH 9.0) and 16% PEG 1000-12.5% K2HPO4-71.5% water (pH 8.0) system.

  17. Determination of ricin by nano liquid chromatography/mass spectrometry after extraction using lactose-immobilized monolithic silica spin column.

    PubMed

    Kanamori-Kataoka, Mieko; Kato, Haruhito; Uzawa, Hirotaka; Ohta, Shigenori; Takei, Yoshiyuki; Furuno, Masahiro; Seto, Yasuo

    2011-08-01

    Ricin is a glycosylated proteinous toxin that is registered as toxic substance by Chemical Weapons convention. Current detection methods can result in false negatives and/or positives, and their criteria are not based on the identification of the protein amino acid sequences. In this study, lactose-immobilized monolithic silica extraction followed by tryptic digestion and liquid chromatography/mass spectrometry (LC/MS) was developed as a method for rapid and accurate determination of ricin. Lactose, which was immobilized on monolithic silica, was used as a capture ligand for ricin extraction from the sample solution, and the silica was supported in a disk-packed spin column. Recovery of ricin was more than 40%. After extraction, the extract was digested with trypsin and analyzed by LC/MS. The accurate masses of molecular ions and MS/MS spectra of the separated peptide peaks were measured by Fourier transform-MS and linear iontrap-MS, respectively. Six peptides, which were derived from the ricin A-(m/z 537.8, 448.8 and 586.8) and B-chains (m/z 701.3, 647.8 and 616.8), were chosen as marker peptides for the identification of ricin. Among these marker peptides, two peptides were ricin-specific. This method was applied to the determination of ricin from crude samples. The monolithic silica extraction removed most contaminant peaks from the total ion chromatogram of the sample, and the six marker peptides were clearly detected by LC/MS. It takes about 5 h for detection and identification of more than 8 ng/ml of ricin through the whole handling, and this procedure will be able to deal with the terrorism using chemical weapon.

  18. Development of an immunoaffinity chromatography column for selective extraction of a new agonist phenylethylamine A from feed, meat and liver samples.

    PubMed

    Mei, Liyun; Cao, Biyun; Yang, Hong; Xie, Yun; Xu, Shouming; Deng, Anping

    2014-01-15

    Phenylethanolamine A (PA) is a new emerged β-adrenergic agonist that has been illegally used as an animal feed additive for growth promotion in China. In this study, an immunoaffinity chromatography (IAC) column for selective extraction of PA from swine feed, meat and liver samples was developed. The IAC column was constructed by covalently coupling specific polyclonal antibody (Ab) against PA to CNBr-activated Sepharose 4B and packed into a common solid phase extraction (SPE) cartridge. The extraction conditions including loading, washing and eluting solutions were carefully optimized. Under optimal conditions, the IAC column was characterized in terms of maximum capacity, selectivity, extraction recovery and stability. The maximum capacity of the ICA for PA extraction was found to be 239.4ng. For selectivity testing, 100ng of other three β-adrenergic agonists (clenbuterol, ractopamine and salbutamol) was separately loaded onto the column, and it was observed that the tested compounds could not be captured on the column, e.g. the column could only selectively recognize PA. The recovery of the IAC for PA extraction was found within 96.47-101.98% when 10, 50 and 100ng PA were separately loaded onto IAC column. The IAC column was also applied to real sample extraction. Swine feed, meat and liver samples were collected and spiked with PA in range of 1.0-20ngg(-1). The spiked and unspiked samples were extracted by IAC column and measured by high performance liquid chromatography (HPLC). It was found that there was no detectable PA in the blank samples, and the extraction recoveries of the IAC for PA from the spiked samples were within 89.48-104.89%. The stability of the column was also tested. It was showed that after 35 times repeated usage, 60% of the maximum capacity was still remained. The proposed IAC was proven to be a feasible extraction method for PA from different matrices with the properties of high maximum capacity, selectivity, extraction efficiency and

  19. The synthesis of surface-glycosylated porous monolithic column via aqueous two-phase graft copolymerization and its application in capillary-liquid chromatography.

    PubMed

    Xiong, Xiyue; He, Haiqin; Shu, Yan; Li, Yuxin; Yang, Zihui; Chen, Yingzhuang; Ma, Ming; Chen, Bo

    2016-12-01

    A facile, flexible process was developed for the preparation of surface-glycosylated porous monolithic columns via aqueous two-phase graft copolymerization of polyethylene glycol diacrylate (PEGDA) and water-soluble dextran (dextran sulfate). The formation of poly(PEGDA) porous skeletons and surface glycosylation were achieved via a one-step process without pre-modification of the dextran. The synthesis conditions were thoroughly optimized. The optimal monolithic column exhibited a large dry state surface area (greater than 400m(2)/g), and it was evaluated as a hydrophilic liquid chromatography (HILIC) stationary phase. A typical HILIC mechanism was observed at high organic solvent content (≥65% acetonitrile). In addition, the resulting monolithic column demonstrated the potential use in analysis of complex biological sample and enviroment water.

  20. A novel ion chromatography cycling-column-switching system for the determination of low-level chlorate and nitrite in high salt matrices.

    PubMed

    Wang, Nani; Wang, Rui Qi; Zhu, Yan

    2012-10-15

    A novel ion chromatography cycling-column-switching system was developed for the determination of chlorate and nitrite in high salt matrices. The simple system included a pump, two valves, a single eluent, and a conductivity detector. Both online pre-concentration and matrix elimination were achieved by this method. The target anions were eluted from the concentrator column to the analytical columns circularly. Chloride matrix was then eliminated completely. The method was applied to the determination of low-level chlorate and nitrite in the chloride matrix. Our experimental results demonstrated that this system is of advantages such as high sensitivity, facile automation and simple sample pretreatment, which might be a promising approach for environmental researches and food control.

  1. Extraction of amphetamines and methylenedioxyamphetamines from urine using a monolithic silica disk-packed spin column and high-performance liquid chromatography-diode array detection.

    PubMed

    Namera, Akira; Nakamoto, Akihiro; Nishida, Manami; Saito, Takeshi; Kishiyama, Izumi; Miyazaki, Shota; Yahata, Midori; Yashiki, Mikio; Nagao, Masataka

    2008-10-24

    To overcome the limitations of solid-phase extraction, we developed a device comprising a spin column packed with octadecyl silane-bonded monolithic silica for extracting amphetamines and methylenedioxyamphetamines from urine. Urine (0.5mL), buffer (0.4mL), and methoxyphenamine (internal standard) were directly put into the preactivated column. The column was centrifuged (3000rpm, 5min) for sample loading and washed. The adsorbed analytes were eluted and analyzed by high-performance liquid chromatography, without evaporation. The results were as follows: linear curves (drug concentrations of 0.2-20microg/mL); correlation coefficients >0.99; detection limit, 0.1microg/mL. The proposed method is not only useful for drugs from biological materials but also highly reproducible for the analysis of these drugs in urine.

  2. Determination of Sudan dyes in chili pepper powder by online solid-phase extraction with a butyl methacrylate monolithic column coupled to liquid chromatography with tandem mass spectrometry.

    PubMed

    Liu, Yao; Wang, Man-Man; Ai, Lian-Feng; Zhang, Chang-Kun; Li, Xin; Wang, Xue-Sheng

    2014-07-01

    A poly(butyl methacrylate-co-ethylene dimethacrylate) monolithic column was fabricated and used as a novel sorbent for online solid-phase extraction coupled to liquid chromatography with tandem mass spectrometry for the simultaneous determination of Sudan I-IV in chili pepper powder. The prepared columns were characterized by scanning electron microscopy, nitrogen adsorption-desorption, and pressure drop measurements. Online solid-phase extraction was performed on the synthesized monolithic column using 10 mM ammonium acetate solution as the loading solution with the aid of an online cleanup chromatography system. The desorption of Sudan I-IV was achieved with acetonitrile as the eluting solution at the flow rate of 0.5 mL/min. The extracted analytes were subsequently eluted into a C18 analytical column for chromatographic separation using a mixture of 10% acetonitrile/90% formic acid (0.5%) solution as the mobile phase. Under the optimized conditions, the developed method had linear range of 1.0-50 μg/kg, a detection limit of 0.3 μg/kg, and a quantification limit of 1.0 μg/kg for each analyte. The intraday and interday recoveries of Sudan I-IV in chili pepper powder samples ranged from 94.8 to 100.9% and 94.9 to 99.4%, respectively. The intraday and interday precision were between 3.37-7.01% and 5.01-7.68%, respectively.

  3. Determination of lansoprazole enantiomers in dog plasma by column-switching liquid chromatography with tandem mass spectrometry and its application to a preclinical pharmacokinetic study.

    PubMed

    Wang, Hao; Sun, Yantong; Meng, Xiangjun; Yang, Bo; Wang, Jian; Yang, Yan; Gu, Jingkai

    2015-09-01

    Lansoprazole, a selective proton pump inhibitor, has a chiral benzimidazole sulfoxide structure and is used for the treatment of gastric acid hypersecretory related diseases. To investigate its stereoselective pharmacokinetics, a column-switching liquid chromatography with tandem mass spectrometry method was developed for the determination of lansoprazole enantiomers in dog plasma using (+)-pantoprazole as an internal standard. After a simple protein precipitation procedure with acetonitrile, matrix components left behind after sample preparation were further eliminated from the sample by reversed-phase chromatography on a C18 column. The fluent was fed to a chiral column for the separation of lansoprazole enantiomers. Baseline separation of lansoprazole enantiomers was achieved on a Chiralcel OZ-RH column using acetonitrile/0.1% formic acid in water (35:65, v/v) as the mobile phase at 40°C. The linearity of the calibration curves ranged from 3 to 800 ng/mL for each enantiomer. Intra- and inter-day precisions ranged from 2.1 to 7.3% with an accuracy of ±1.7% for (+)-lansoprazole, and from 1.6 to 6.9% with an accuracy of ±3.5% for (-)-lansoprazole, respectively. The validated method was successfully applied for the stereoselective pharmacokinetic study of lansoprazole in beagle dog after intravenous infusion.

  4. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of chlorinated pesticides in aquatic tissue by capillary-column gas chromatography with electron-capture detection

    USGS Publications Warehouse

    Leiker, Thomas J.; Madsen, J.E.; Deacon, J.R.; Foreman, W.T.

    1995-01-01

    A method for the determination of chlorinated organic compounds in aquatic tissue by dual capillary-column gas chromatography with electron-capture detection is described. Whole-body-fish or corbicula tissue is homogenized, Soxhlet extracted, lipid removed by gel permeation chromatography, and fractionated using alumina/silica adsorption chromatography. The extracts are analyzed by dissimilar capillary-column gas chromatography with electron-capture detection. The method reporting limits are 5 micrograms per kilogram (μg/kg) for chlorinated compounds, 50 μg/kg for polychlorinated biphenyls, and 200 μg/kg for toxaphene.

  5. Determination of methandrostenolone and its metabolites in equine plasma and urine by coupled-column liquid chromatography with ultraviolet detection and confirmation by tandem mass spectrometry.

    PubMed

    Edlund, P O; Bowers, L; Henion, J

    1989-02-24

    Monitoring steroid use requires an understanding of the metabolism in the species in question and development of sensitive methods for screening of the steroid or its metabolites in urine. Qualitative information for confirmation of methandrostenolone and identification of its metabolites was primarily obtained by coupled-column high-performance liquid chromatography-tandem mass spectrometry. The steroids and a sulphuric acid conjugate were isolated and identified by their daughter ion mass spectra in the urine of both man and the horse following administration of methandrostenolone. Spontaneous hydrolysis of methandrostenolone sulphate gave 17-epimethandrostenolone and several dehydration products. This reaction had a half-life of 16 min in equine urine at 27 degrees C. Mono- and dihydroxylated metabolites were also identified. Several screening methods were evaluated for detection and confirmation of methandrostenolone use including thin-layer chromatography and high-performance liquid chromatography. Coupled-column liquid chromatography was used for automated clean-up of analytes difficult to isolate by manual methods. The recovery of methandrostenolone was 101 +/- 3.3% (mean +/- S.D.) at 6.5 ng/ml and both methandrostenolone and 17-epimethandrostenolone were quantified in urine by ultraviolet detection up to six days after a 250-mg intramuscular dose to a horse. The utility of on-line tandem mass spectrometry for confirmation of suspected metabolites is also shown.

  6. Simultaneous determination of iodide and iodate in povidone iodine solution by ion chromatography with homemade and exchange capacity controllable columns and column-switching technique.

    PubMed

    Huang, Zhongping; Zhu, Zuoyi; Subhani, Qamar; Yan, Wenwu; Guo, Weiqiang; Zhu, Yan

    2012-08-17

    A simple ion chromatographic method for simultaneous detection of iodide and iodate in a single running was proposed, with columns packed with homemade functionalized polystyrene-divinylbenzene (PS-DVB) resins and column-switching technique. Homemade resins were functionalized with controllable amounts of quaternary ammonium groups. The low-capacity anion-exchange column and high-capacity anion-exchange column were prepared, due to the resins having different exchange capacities. With this method, iodide and iodate in povidone iodine solution were detected simultaneously in a short time with iodide being eluted off first. A series of standard solutions consisting of target anions of various concentrations from 0.01 mg/L to 100 mg/L were analyzed. Each anion exhibited satisfactory linearity, with correlation coefficient r ≥ 0.9990. The detection limits (LODs) for iodide and iodate obtained by injecting 100 μL of sample were 5.66 and 14.83 μg/L (S/N=3), respectively. A spiking study was performed with satisfactory recoveries between 101.2% and 100.6% for iodide and iodate.

  7. Monolithic stationary phases with incorporated fumed silica nanoparticles. Part II. Polymethacrylate-based monolithic column with "covalently" incorporated modified octadecyl fumed silica nanoparticles for reversed-phase chromatography.

    PubMed

    Aydoğan, Cemil; El Rassi, Ziad

    2016-05-06

    This study is concerned with the incorporation of surface modified fumed silica nanoparticles (FSNPs) into polymethacrylate based monolithic columns for use in reversed phase chromatography (RPC) of small solutes and proteins. First, FSNPs were modified with 3-(trimethoxysilyl)propylmethacrylate (TMSPM) to yield the "hybrid" methacryloyl fumed silica nanoparticle (MFSNP) monomer. The resulting MFSNP was then mixed with glyceryl monomethacrylate (GMM) and ethylene dimethacrylate (EDMA) in a binary porogenic solvent composed of cyclohexanol and dodecanol, and the in situ copolymerization of MFSNP, GMM and EDMA was performed in a stainless steel column of 4.6 mm i.d. The silanol groups of the hybrid monolith thus obtained were grafted with octadecyl ligands by perfusing the hybrid monolithic column with a solution of 4% w/v of dimethyloctadecylchlorosilane (DODCS) in toluene while the column was maintained at 110°C for 6h (in a heated HPLC oven). One of the originalities of this study was to demonstrate MFSNP as a novel derivatized "hybrid monomer" in making RPC monolithic columns with surface bound octadecyl ligands. In this respect, the RPC behavior of the monolithic column with "covalently" incorporated FNSPs having surface grafted octadecyl ligands was evaluated with alkylbenzenes, aniline derivatives and phenolic compounds. The results showed that the hybrid poly(GMA-EDMA-MFSNP) having surface bound octadecyl ligands exhibited hydrophobic interactions under reversed phase elution conditions. Furthermore, six standard proteins were baseline separated on the column using a 10min linear gradient elution at increasing ACN concentration in the mobile phase at a flow rate of 1.0mL/min using a 10 cm×4.6mm i.d. column. The relative standard deviations (RSDs) for the retention times of the tested solutes were lower than 2.1% and 2.4% under isocratic elution and gradient elution conditions, respectively.

  8. Relating pressure tuned coupled column ensembles with the solvation parameter model for tunable selectivity in gas chromatography.

    PubMed

    Sharif, Khan M; Kulsing, Chadin; Chin, Sung-Tong; Marriott, Philip J

    2016-07-15

    The differential pressure drop of carrier gas by tuning the junction point pressure of a coupled column gas chromatographic system leads to a unique selectivity of the overall separation, which can be tested using a mixture of compounds with a wide range of polarity. This study demonstrates a pressure tuning (PT) GC system employing a microfluidic Deans switch located at the mid-point of the two capillary columns. This PT system allowed variations of inlet-outlet pressure differences of the two columns in a range of 52-17psi for the upstream column and 31-11psi for the downstream column. Peak shifting (differential migration) of compounds due to PT difference are related to a first order regression equation in a Plackett-Burman factorial study. Increased first (upstream) column pressure drop makes the second column characteristics more significant in the coupled column retention behavior, and conversely increased second (downstream) column pressure drop makes the first column characteristics more apparent; such variation can result in component swapping between polar and non-polar compounds. The coupled column system selectivity was evaluated in terms of linear solvation energy relationship (LSER) parameters, and their relation with different pressure drop effects has been constructed by applying multivariate principle component analysis (PCA). It has been found that the coupled column PT system descriptors provide a result that shows a clear clustering of different pressure settings, somewhat intermediate between those of the two commercial columns. This is equivalent to that obtained from a conventional single-column GC analysis where the interaction energy contributed from the stationary phases can be significantly adjusted by choice of midpoint PT. This result provides a foundation for pressure differentiation for selectivity enhancement.

  9. Preparation and evaluation of a phenylboronate affinity monolith for selective capture of glycoproteins by capillary liquid chromatography.

    PubMed

    Lin, Zi An; Pang, Ji Lei; Lin, Yao; Huang, Hui; Cai, Zong Wei; Zhang, Lan; Chen, Guo Nan

    2011-08-21

    A phenylboronate affinity monolith was prepared and applied to the selective capture of glycoproteins from unfractionated protein mixtures. The monolith was synthesized in a 100 μm i.d capillary by an in situ polymerization procedure using a pre-polymerization mixture consisting of 4-vinylphenylboronic acid (VPBA) as functional monomer, ethylene dimethacrylate (EDMA) as crosslinker, diethylene glycol and ethylene glycol as binary porogenic solvents, and azobisisobutyronitrile (AIBN) as initiator. The prepared monolith was characterized in terms of the morphology, pore property, and recognition property. The selectivity and dynamic binding capacity were evaluated by using standard glycoproteins and nonglycoproteins as model proteins. The chromatographic results demonstrated that the phenylboronate affinity monolith had higher selectivity and binding capacity for glycoprotein than nonglycoprotein. The resulting phenylboronate affinity monolith was used as the sorbent for in-tube solid phase microextraction (in-tube SPME), and the extraction performance of the monolith was assessed by capture of ovalbumin from egg white sample.

  10. Chromatography column comparison and rapid pretreatment for the simultaneous analysis of amantadine, rimantadine, acyclovir, ribavirin, and moroxydine in chicken muscle by ultra high performance liquid chromatography and tandem mass spectrometry.

    PubMed

    Zhang, Qiaoyan; Xiao, Chaogeng; Wang, Wei; Qian, Mingrong; Xu, Jie; Yang, Hua

    2016-10-01

    In this work, a chromatography column comparison and rapid pretreatment development were carried out. A multi-class method was built based on the quick, easy, cheap, effective, rugged, and safe pretreatment method with hydrophilic interaction ultra high performance liquid chromatography and tandem mass spectrometry for the high-throughput analysis of five antivirals in chicken muscle. The HSS T3 column, BEH HILIC column and BEH Amide column were studied, and their chemical functionalities and chromatographic separation effectiveness were compared. The BEH Amide column was selected to perform the mass spectrometry analysis under the hydrophilic interaction chromatography mode. First, a different strategy without adding MgSO4 and NaCl into the muscle samples was considered. Then, different concentrations of formic acid, acetic acid, and ammonia in acetonitrile were compared for better extraction efficiency. Nine sorbents (C18 , PSA, NH2 , Florisil, Alumina-B, Alumina-N, PestiCarb, NANO, and NANO-NH2 ) were studied. The optimized procedure consisted of the use of 10% acetic acid in acetonitrile for the extraction solvent and NANO-NH2 for clean-up. NANO-NH2 had not been applied in other matrix and pollutants so far. The developed method provided favorable trueness, precision, and acceptable matrix effect. Meanwhile, the method was sensitive, the limits of detection of amantadine, rimantadine, acyclovir, ribavirin, and moroxydine achieved were 0.56, 0.50, 0.30, 2.22, and 0.51 μg/kg, respectively, and were successfully applied for the routine detection of antivirals in the chicken samples.

  11. Synthesis of 17 beta-hydroxyandrost-4-en-3-one-7 alpha-(biotinyl-6-N-hexylamide), a conjugate useful for affinity chromatography and for testosterone immunoassays.

    PubMed

    Luppa, P; Hauck, S; Schwab, I; Birkmayer, C; Hauptmann, H

    1996-01-01

    We describe the synthesis of 17 beta-hydroxyandrost-4-en-3-one-7 alpha-(biotinyl-6-N-hexylamide) from 17 beta-hydroxyandrost-4-en-3-one (testosterone) via copper-catalyzed 1,6 Michael addition of a 6-(tertbutyldimethylsilyloxyhexyl) chain to 6-dehydrotestosterone 17 beta-acetate. After chromatographic separation of the 7 alpha-isomer from the alpha / beta mixture and cleavage of the silyl ether, the alcohol was oxidized to the 6-hexanal side chain and then subjected to reductive amination. The resulting primary amine is easily biotinylated using biotinyl-N-hydroxysuccinimide ester. The overall yield for the epimeric 7 alpha-end product was 30%. The absolute configurations of the epimers were investigated by 1H NMR studies by the nuclear Overhauser effect. We introduced a biotin label to the testosterone molecule at ring position 7 in compliance with Landsteiner's principle, which states that antibody specificity is directed primarily at that portion of the hapten furthest from the functional group linking it to the carrier protein. Thus, this negligible alteration in comparison to the structure of the respective testosterone hapten used to elicit antibodies offers the feasibility of applying the testosterone derivative as an optimal immunoadsorbent in affinity chromatography. The 7 alpha-biotinylated testosterone was used to obtain active antitestosterone antibodies from a specific antiserum by affinity chromatography. This was achieved by attaching the biotinylated testosterone to agarose-coupled streptavidin beads. Accordingly, a 3H-testosterone-binding test demonstrated a 20-fold increase in affinity of the purified antibody to the steroid compared to the original antiserum, and a recovery of > 80% could be obtained. The antitestosterone antibody, obtained by that method, is an effective component for use in a competitive immunoassay for testosterone in human sera. An assay configuration is conceivable with the same 7 alpha-biotinylated testosterone employed as

  12. A practical strategy for using miniature chromatography columns in a standardized high-throughput workflow for purification development of monoclonal antibodies.

    PubMed

    Welsh, John P; Petroff, Matthew G; Rowicki, Patricia; Bao, Haiying; Linden, Thomas; Roush, David J; Pollard, Jennifer M

    2014-01-01

    The emergence of monoclonal antibody (mAb) therapies has created a need for faster and more efficient bioprocess development strategies in order to meet timeline and material demands. In this work, a high-throughput process development (HTPD) strategy implementing several high-throughput chromatography purification techniques is described. Namely, batch incubations are used to scout feasible operating conditions, miniature columns are then used to determine separation of impurities, and, finally, a limited number of lab scale columns are tested to confirm the conditions identified using high-throughput techniques and to provide a path toward large scale processing. This multistep approach builds upon previous HTPD work by combining, in a unique sequential fashion, the flexibility and throughput of batch incubations with the increased separation characteristics for the packed bed format of miniature columns. Additionally, in order to assess the applicability of using miniature columns in this workflow, transport considerations were compared with traditional lab scale columns, and performances were mapped for the two techniques. The high-throughput strategy was utilized to determine optimal operating conditions with two different types of resins for a difficult separation of a mAb monomer from aggregates. Other more detailed prediction models are cited, but the intent of this work was to use high-throughput strategies as a general guide for scaling and assessing operating space rather than as a precise model to exactly predict performance.

  13. Affinity membrane chromatography: relationship of dye-ligand type to surface polarity and their effect on lysozyme separation and purification.

    PubMed

    Arica, M Yakup; Yilmaz, Meltem; Yalçin, Emine; Bayramoğlu, Gülay

    2004-06-15

    Two different dye-ligands, i.e. Procion Brown MX-5BR (RB-10) and Procion Green H-4G (RG-5) were immobilised onto poly(2-hydroxyethylmethacrylate) (pHEMA) membranes. The polarities of the affinity membranes were determined by contact angle measurements. Separation and purification of lysozyme from solution and egg white were investigated. The adsorption data was analysed using two adsorption kinetic models the first order and the second order to determine the best-fit equation for the separation of lysozyme using affinity membranes. The second-order equation for the adsorption of lysozyme on the RB-10 and RG-5 immobilised membranes systems is the most appropriate equation to predict the adsorption capacity for the affinity membranes. The reversible lysozyme adsorption on the RB-10 and RG-5 did not follow the Langmuir model, but obeyed the Temkin and Freundlich isotherm model. Separation and purification were monitored by determining the lysozyme activity using Micrococcus lysodeikticus as substrate. The purities of the eluted lysozyme, as determined by HPLC, were 76 and 92% with recovery 63 and 77% for RB-10 and RG-5 membranes, respectively. For the separation and purification of lysozyme the RG-5 immobilised membrane provided the best results. The affinity membranes are stable when subjected to sanitization with sodium hydroxide after repeated adsorption-elution cycles.

  14. Proteomic analysis with integrated multiple dimensional liquid chromatography/mass spectrometry based on elution of ion exchange column using pH steps.

    PubMed

    Dai, Jie; Shieh, Chia Hui; Sheng, Quan-Hu; Zhou, Hu; Zeng, Rong

    2005-09-15

    A novel integrated multidimensional liquid chromatography (IMDL) method is demonstrated for the separation of peptide mixtures by two-dimensional HPLC coupled with ion trap mass spectrometry. The method uses an integrated column, containing both strong cation exchange and reversed-phase sections for two-dimensional liquid chromatography. The peptide mixture was fractionated by a pH step using a series of pH buffers, followed by reversed-phase chromatography. Since no salt was used during separation, the integrated multidimensional liquid chromatography can be directly connected to mass spectrometry for peptide analysis. The pH buffers were injected from an autosampler, and the entire process can be carried out on a one-dimensional liquid chromatography system. In a single analysis, the IMDL system, coupled with linear ion trap mass spectrometry, identified more than 2000 proteins in mouse liver. The peptides were eluted according to their pI distribution. The resolution of the pH fractionation is approximately 0.5 pH unit. The method has low overlapping across pH fractions, good resolution of peptide mixture, and good correlation of peptide pIs with pH steps. This method provides a technique for large-scale protein identification using existing one-dimensional HPLC systems.

  15. Monolithic stationary phases with incorporated fumed silica nanoparticles. Part I. Polymethacrylate-based monolithic column with incorporated bare fumed silica nanoparticles for hydrophilic interaction liquid chromatography.

    PubMed

    Aydoğan, Cemil; El Rassi, Ziad

    2016-05-06

    Fumed silica nanoparticles (FSNPs), were incorporated for the first time into a polymethacrylate monolithic column containing glyceryl monomethacrylate (GMM) and ethylene dimethacrylate (EDMA) in order to develop a new monolithic column for hydrophilic interaction high performance liquid chromatography (HILIC). When compared to poly(GMM-EDMA) monolithic column without FSNPs, the same monolithic column with incorporated FSNPs yielded important effects on HILIC separations. The effects of monomers and FSNPs content of the polymerization mixture on the performance of the monolithic column were examined in details, and the optimized stationary phase was investigated over a wide range of mobile phase composition with polar acidic, weakly basic and neutral analytes including hydroxy benzoic acids, nucleotides, nucleosides, dimethylformamide, formamide and thiourea. The retention of these analytes was mainly controlled by hydrophilic interactions with the FSNPs and electrostatic repulsion from the negatively charged silica surface in the case of hydroxy benzoic acids and nucleotides. The electrostatic repulsion was minimized by decreasing the pH of the aqueous component of the mobile phase, which in turn enhanced the retention of acidic solutes. Nucleotides were best separated using step gradient elution at decreasing pH as well as ACN concentration in the mobile phase. Improved peak shape and faster analysis of nucleosides were attained by a fast linear gradient elution with a shallow decrease in the ACN content of the ACN-rich mobile phase. The run-to-run and column-to-column reproducibility were satisfactory. The percent relative standard deviations (%RSDs) for the retention times of tested solutes were lower than 2.5% under isocratic conditions and lower than 3.5 under gradient conditions.

  16. Accelerated quantification of amphetamine enantiomers in human urine using chiral liquid chromatography and on-line column-switching coupled with tandem mass spectrometry.

    PubMed

    Hädener, Marianne; Bruni, Pia S; Weinmann, Wolfgang; Frübis, Matthias; König, Stefan

    2017-02-01

    Amphetamine (AM) is a powerful psychostimulant existing in two enantiomeric forms. Stereoselective analysis of AM in biosamples can assist clinicians and forensic experts in differentiating between abuse of illicitly synthesized racemic AM and ingestion of pharmaceutical AM formulations containing either S-AM or different proportions of the S- and R-enantiomers. Therefore, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying AM enantiomers in urine was newly developed. The method comprised dilution with water, followed by injection of the diluted sample onto an achiral C18 trapping column for purification and subsequent backflush elution to a chiral Lux 3 μm AMP LC column by means of a switching valve. An isocratic mobile phase of 25 % acetonitrile in 0.1 M aqueous ammonia was used for enantiomeric separation. Injection, cleanup, and backflush of the next sample were performed before the previous sample had eluted from the analytical column, thus enabling simultaneous enantioseparation of up to three samples within the analytical column. This novel chromatographic concept allowed for increased sample throughput by accelerating both the sample preparation and the LC analysis. Analyte detection was accomplished by electrospray ionization in positive ion mode and selected reaction monitoring using a triple-stage quadrupole mass spectrometer. The method was successfully validated through assessment of its linearity, lower limit of quantification, accuracy and precision, selectivity, matrix effect, carry-over, dilution integrity, and re-injection reproducibility. Linearity ranged from 0.05 to 25 mg/L for both enantiomers. Proof of the method included analysis of urine samples obtained from drug abusers and patients receiving an S-AM prodrug. Graphical Abstract Enantioselective determination of amphetamine in human urine using liquid chromatography with achiral-chiral column-switching and tandem mass spectrometry.

  17. Advantages of monolithic over particulate columns for multiresidue analysis of organic pollutants by in-tube solid-phase microextraction coupled to capillary liquid chromatography.

    PubMed

    Moliner-Martínez, Y; Molins-Legua, C; Verdú-Andrés, J; Herráez-Hernández, R; Campíns-Falcó, P

    2011-09-16<