Science.gov

Sample records for agar contact plates

  1. Hyperspectral imaging for detecting pathogens grown on agar plates

    NASA Astrophysics Data System (ADS)

    Yoon, Seung Chul; Lawrence, Kurt C.; Siragusa, Gregory R.; Line, John E.; Park, Bosoon; Windham, William R.

    2007-09-01

    This paper is concerned with the development of a hyperspectral imaging technique for detecting and identifying one of the most common foodborne pathogens, Campylobacter. Direct plating using agars is an effective tool for laboratory tests and analyses of microorganisms. The morphology (size, growth pattern, color, etc.) of colonies grown on agar plates has been widely used to tentatively differentiate organisms. However, it is sometimes difficult to differentiate target organisms like Campylobacters from other contaminants grown together on the same agar plates. A hyperspectral imaging system operating at the visible and near infrared (VNIR) spectral region from 400 nm to 900 nm was set up to measure spectral signatures of 17 different Campylobacter and non-Campylobacter subspecies. Protocols for culturing, imaging samples and for calibrating measured data were developed. The VNIR spectral library of all 17 organisms commonly encountered in poultry was established from calibrated hyperspectral images. A classification algorithm was developed to locate and identify Campylobacters, non-Campylobacter contaminants, and background agars with 99.29% accuracy. This research has a potential to be expanded to detect other pathogens grown on agar media.

  2. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  3. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  4. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  5. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  6. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  7. A modified agar plate method for detection of Strongyloides stercoralis.

    PubMed

    Koga, K; Kasuya, S; Khamboonruang, C; Sukhavat, K; Ieda, M; Takatsuka, N; Kita, K; Ohtomo, H

    1991-10-01

    The agar plate method is a new technique with high detection rates for coprological diagnosis of human strongyloidiasis. This report details modifications of the technique and establishes a standardized procedure. We recommend that all plates should be carefully observed using a microscope because macroscopic observation can lead to false negative results. It is also advisable to pour formalin solution directly into microscopically positive dishes to collect worms by sedimentation. This procedure enables one to observe worms otherwise hidden. Sealing dishes with adhesive tape prevents larvae from crawling out of the dishes, eliminating any possibility in the reduction of detection rates, and greatly improves the safety conditions for the technician performing the procedure. We consider the agar plate method to be superior to the filter paper method in detecting Strongyloides, and we believe that it will eventually become the technique of choice.

  8. Possible influence of surfactants and proteins on the efficiency of contact agar microbiological surface sampling.

    PubMed

    Deckers, Sylvie M; Sindic, Marianne; Anceau, Christine; Brostaux, Yves; Detry, Jean G

    2010-11-01

    Agar contact microbiological sampling techniques, based on a transfer of the microorganisms present on a surface to a culture medium, are widely used to assess and control surface cleanliness and to evaluate microbial contamination levels. The effectiveness of these techniques depends on many environmental parameters that influence the strength of attachment of the bacteria to the surface. In the present study, stainless steel and high density polyethylene surfaces were inoculated with known concentrations of Staphylococcus epidermidis. Following an experimental design, the surfaces were sampled with different types of replicate organism direct agar contact plates and Petrifilm; results indicated that recovery rates were influenced by the presence of egg white albumin or Tween 80 in the inoculum solutions or by the introduction of surfactants into the contact agar of the microbiological sampling techniques. The techniques yielded significantly different results, depending on sampling conditions, underlining the need for a standardization of laboratory experiments to allow relevant comparisons of such techniques.

  9. Automated agar plate streaker: a linear plater on Society for Biomolecular Sciences standard plates.

    PubMed

    King, Gregory W; Kath, Gary S; Siciliano, Sal; Simpson, Neal; Masurekar, Prakash; Sigmund, Jan; Polishook, Jon; Skwish, Stephen; Bills, Gerald; Genilloud, Olga; Peláez, Fernando; Martín, Jesus; Dufresne, Claude

    2006-09-01

    Several protocols for bacterial isolation and techniques for aerobic plate counting rely on the use of a spiral plater to deposit concentration gradients of microbial suspensions onto a circular agar plate to isolate colony growth. The advantage of applying a gradient of concentrations across the agar surface is that the original microbiological sample can be applied at a single concentration rather than as multiple serial dilutions. The spiral plater gradually dilutes the sample across a compact area and therefore saves time preparing dilutions and multiple agar plates. Commercial spiral platers are not automated and require manual sample loading. Dispensing of the sample volume and rate of gradients are often very limited in range. Furthermore, the spiral sample application cannot be used with rectangular microplates. Another limitation of commercial spiral platers is that they are useful only for dilute, filtered suspensions and cannot plate suspensions of coarse organic particles therefore precluding the use of many kinds of microorganism-containing substrata. An automated agar plate spreader capable of processing 99 rectangular microplates in unattended mode is described. This novel instrument is capable of dispensing discrete volumes of sample in a linear pattern. It can be programmed to dispense a sample suspense at a uniform application rate or across a decreasing concentration gradient.

  10. Development of a selective agar plate for the detection of Campylobacter spp. in fresh produce.

    PubMed

    Yoo, Jin-Hee; Choi, Na-Young; Bae, Young-Min; Lee, Jung-Su; Lee, Sun-Young

    2014-10-17

    This study was conducted to develop a selective medium for the detection of Campylobacter spp. in fresh produce. Campylobacter spp. (n=4), non-Campylobacter (showing positive results on Campylobacter selective agar) strains (n=49) isolated from fresh produce, indicator bacteria (n=13), and spoilage bacteria isolated from fresh produce (n=15) were plated on four Campylobacter selective media. Bolton agar and modified charcoal cefoperazone deoxycholate agar (mCCDA) exhibited higher sensitivity for Campylobacter spp. than did Preston agar and Hunt agar, although certain non-Campylobacter strains isolated from fresh produce by using a selective agar isolation method, were still able to grow on Bolton agar and mCCDA. To inhibit the growth of non-Campylobacter strains, Bolton agar and mCCDA were supplemented with 5 antibiotics (rifampicin, polymyxin B, sodium metabisulfite, sodium pyruvate, ferrous sulfate) and the growth of Campylobacter spp. (n=7) and non-Campylobacter strains (n=44) was evaluated. Although Bolton agar supplemented with rifampicin (BR agar) exhibited a higher selectivity for Campylobacter spp. than did mCCDA supplemented with antibiotics, certain non-Campylobacter strains were still able to grow on BR agar (18.8%). When BR agar with various concentrations of sulfamethoxazole-trimethoprim were tested with Campylobacter spp. (n=8) and non-Campylobacter (n=7), sulfamethoxazole-trimethoprim was inhibitory against 3 of 7 non-Campylobacter strains. Finally, we validated the use of BR agar containing 50mg/L sulfamethoxazole (BRS agar) or 0.5mg/L ciprofloxacin (BRCS agar) and other selective agars for the detection of Campylobacter spp. in chicken and fresh produce. All chicken samples were positive for Campylobacter spp. when tested on mCCDA, BR agar, and BRS agar. In fresh produce samples, BRS agar exhibited the highest selectivity for Campylobacter spp., demonstrating its suitability for the detection of Campylobacter spp. in fresh produce.

  11. Membrane-assisted culture of fungal mycelium on agar plates for RNA extraction and pharmacological analyses.

    PubMed

    Lange, Mario; Müller, Carolin; Peiter, Edgar

    2014-05-15

    Fungal mycelium grown in liquid culture is easy to harvest for RNA extraction and gene expression analyses, but liquid cultures often develop rather heterogeneously. In contrast, growth of fungal mycelium on agar plates is highly reproducible. However, this biological material cannot be harvested easily for downstream analyses. This article describes a PVDF (polyvinylidene difluoride) membrane-assisted agar plate culture method that enables the harvest of mycelium grown on agar plates. This culture method leads to a strongly reduced variation in gene expression between biological replicates and requires less growth space as compared with liquid cultures.

  12. Mass production of spores of lactic acid-producing Rhizopus oryzae NBRC 5384 on agar plate.

    PubMed

    Yamane, Tsuneo; Tanaka, Ryosuke

    2013-01-01

    Mass production of sporangiospores (spores) of Rhizopus oryzae NBRC 5384 (identical to NRRL 395 and ATCC 9363) on potato-dextrose-agar medium was studied aiming at starting its L(+)-lactic acid fermentation directly from spore inoculation. Various parameters including harvest time, sowed spore density, size of agar plate, height of air space, and incubation mode of plate (agar-on-bottom or agar-on-top) were studied. Ordinarily used shallow Petri dishes were found out to be unsuitable for the full growth of R. oryzae sporangiophores. In a very wide range of the sowed spore density, the smaller it was, the greater the number of the harvested spores was. It was also interesting to find out that R. oryzae grown downward vertically with a deep air space in an agar-on-top mode gave larger amount of spores than in an agar-on-bottom mode at 30°C for 7-day cultivation. Scale-up of the agar plate culture from 26.4 to 292 cm(2) was studied, resulting in the proportional relationship between the number of the harvested spores/plate and the plate area in the deep Petri dishes. The number of plates of 50 cm in diameter needed for 100 m(3) industrial submerged fermentation started directly from 2 × 10(5) spores/mL inoculum size was estimated as about 6, from which it was inferred that such a fermentation would be feasible. Designing a 50 cm plate and a method of spreading and collecting the spores were suggested. Bioprocess technological significance of the "full-scale industrial submerged fermentation started directly from spore inoculation omitting pre-culture" has been discussed.

  13. Development of hyperspectral imaging technique for salmonella enteritidis and typhimurium on agar plates

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Salmonella is a common cause of foodborne disease resulting from the consumption of contaminated food products. Although a direct plating method is widely used for presumptive positive screening of pathogenic Salmonella colonies on agar plates, it is labor-intensive, time-consuming and also prone to...

  14. Strongyloidiasis detected by the agar plate culture method among patients infected by HIV.

    PubMed

    Urdez-Hernández, E; Jiménez-Galán, S; Antonio-Manríquez, M; DE León-Juárez, E A; Terrazas-Estrada, J J; Hernández-García, M C; García-Zaldívar, P; Estrada-Aguilera, A

    1999-10-01

    To evaluate the rate of strongyloidiasis among HIV/AIDS patients, stools and duodenal juice were examined using the agar plate culture method. From January to June 1993, a total of 60 HIV/AIDS patients were required for duodenal aspirate and three serial samples of freshly passed stools. Stools and duodenal aspirate were dispensed on an agar plate culture; after incubation at 28 degrees C during 48 h, screening of plates was made at 10 x. The presence of furrows and worms of short buccal chamber and prominent genital primordium were positive for Strongyloides stercoralis. Most patients were men (91.7%); their mean age, of 33.9 years (SD +/- 10.6); their median CD4(+) T-cells count, of 105/microL (range of 12 to 646). S. stercoralis was detected in three patients (5%). In duodenal juice, the three patients showed the parasite, but in feces, only two (3.3%). In these two individuals, the worms were found in feces by agar culture and Faust's concentration method. The rate of S. stercoralis in feces of HIV/AIDS individuals (3.3%) by agar culture method was similar to that formerly reported from the general Mexican population (2.9%) using standard concentration procedures. Hence, in this immunocompromised population of a low prevalence city, there was no advantage to using an agar plate culture for strongyloidiasis.

  15. Evaluation of an Automated Instrument for Inoculating and Spreading Samples onto Agar Plates.

    PubMed

    Glasson, J H; Guthrie, L H; Nielsen, D J; Bethell, F A

    2008-04-01

    The findings from a preliminary assessment of a new instrument designed for the inoculation and spreading of specimens for microbiological analysis onto agar plates are described. The study found that the instrument was able to select full or biplates from a number of input cassettes, each containing different agar types. Samples were then inoculated by the instrument onto the agar surfaces and spread by a novel plastic applicator. Following this, the instrument labeled the plates and sorted them into a number of specified output stations. It was found that the instrument was able to inoculate and spread samples over a greater proportion of the agar plate surface than the manual loop-to-plate method. As a consequence, up to 44% more usable colonies were produced per plate from clinical specimens and standard cultures. Viable counts showed that the instrument was able to detect as few as 10(2) CFU/ml in fluids and also facilitated the enumeration of organisms, particularly in specimens such as urine.

  16. Hyperspectral image reconstruction using RGB color for foodborne pathogen detection on agar plates

    NASA Astrophysics Data System (ADS)

    Yoon, Seung-Chul; Shin, Tae-Sung; Park, Bosoon; Lawrence, Kurt C.; Heitschmidt, Gerald W.

    2014-03-01

    This paper reports the latest development of a color vision technique for detecting colonies of foodborne pathogens grown on agar plates with a hyperspectral image classification model that was developed using full hyperspectral data. The hyperspectral classification model depended on reflectance spectra measured in the visible and near-infrared spectral range from 400 and 1,000 nm (473 narrow spectral bands). Multivariate regression methods were used to estimate and predict hyperspectral data from RGB color values. The six representative non-O157 Shiga-toxin producing Eschetichia coli (STEC) serogroups (O26, O45, O103, O111, O121, and O145) were grown on Rainbow agar plates. A line-scan pushbroom hyperspectral image sensor was used to scan 36 agar plates grown with pure STEC colonies at each plate. The 36 hyperspectral images of the agar plates were divided in half to create training and test sets. The mean Rsquared value for hyperspectral image estimation was about 0.98 in the spectral range between 400 and 700 nm for linear, quadratic and cubic polynomial regression models and the detection accuracy of the hyperspectral image classification model with the principal component analysis and k-nearest neighbors for the test set was up to 92% (99% with the original hyperspectral images). Thus, the results of the study suggested that color-based detection may be viable as a multispectral imaging solution without much loss of prediction accuracy compared to hyperspectral imaging.

  17. Increased sensitivity of routine laboratory detection of Strongyloides stercoralis and hookworm by agar-plate culture.

    PubMed

    Jongwutiwes, S; Charoenkorn, M; Sitthichareonchai, P; Akaraborvorn, P; Putaporntip, C

    1999-01-01

    The efficacy of agar-plate culture has been evaluated for the detection of Strongyloides stercoralis and hookworm, compared with direct smear, the formalin-ether sedimentation technique and the filter-paper method. Of 1085 stool samples from the routine laboratory service at King Chulalongkorn Memorial Hospital in Bangkok, 241 samples harboured S. stercoralis, 153 hookworm and 2 Rhabditis hominis. The recovery rate of S. stercoralis by agar-plate culture is significantly superior to the other methods (P < 0.005). The ratios of positive results from the methods used to the total number of S. stercoralis-positive cases were as follows: 1:1.03 by agar-plate culture, 1:1.85 by the filter-paper method, 1:1.98 by the sedimentation technique and 1:10.48 by direct stool smear. A similar trend of the efficacy ratio of each method was obtained for hookworm detection. The characteristic furrows left by hookworm larvae, and larvae and adults of S. stercoralis could be used for preliminary species identification. Daily search for furrows on agar plates for up to 6 consecutive days resulted in an increased sensitivity for diagnosis of both S. stercoralis and hookworm infections.

  18. Hyperspectral image reconstruction using RGB color for foodborne pathogen detection on agar plates

    Technology Transfer Automated Retrieval System (TEKTRAN)

    This paper reports the latest development of a color vision technique for detecting colonies of foodborne pathogens grown on agar plates with a hyperspectral image classification model that was developed using full hyperspectral data. The hyperspectral classification model depended on reflectance sp...

  19. An Agar-Based Method for Plating Marine Protozoan Parasites of the Genus Perkinsus

    PubMed Central

    Cold, Emma R.; Freyria, Nastasia J.; Martínez Martínez, Joaquín; Fernández Robledo, José A.

    2016-01-01

    The genus Perkinsus includes protozoan parasites of mollusks responsible for losses in the aquaculture industry and hampering the recovery of natural shellfish beds worldwide, and they are a key taxon for understanding intracellular parasitism adaptations. The ability to propagate the parasite in liquid media, in the absence of the host, has been crucial for improving understanding of its biology; however, alternative techniques to grow the parasite are needed to explore other basic aspects of the Perkinsus spp. biology. We optimized a DME: Ham’s F12–5% FBS- containing solid agar medium for plating Perkinsus marinus. This solid medium supported trophozoite propagation both by binary fission and schizogony. Colonies were visible to the naked eye 17 days after plating. We tested the suitability of this method for several applications, including the following: 1) Subcloning P. marinus isolates: single discrete P. marinus colonies were obtained from DME: Ham’s F12–5% FBS– 0.75% agar plates, which could be further propagated in liquid medium; 2) Subcloning engineered Perkinsus mediterraneus MOE[MOE]: GFP by streaking cultures on plates; 3) Chemical susceptibility: Infusing the DME: Ham’s F12–5% FBS– 0.75% agar plates with triclosan resulted in inhibition of the parasite propagation in a dose-dependent manner. Altogether, our plating method has the potential for becoming a key tool for investigating diverse aspects of Perkinsus spp. biology, developing new molecular tools, and for biotechnological applications. PMID:27149378

  20. An Agar-Based Method for Plating Marine Protozoan Parasites of the Genus Perkinsus.

    PubMed

    Cold, Emma R; Freyria, Nastasia J; Martínez Martínez, Joaquín; Fernández Robledo, José A

    2016-01-01

    The genus Perkinsus includes protozoan parasites of mollusks responsible for losses in the aquaculture industry and hampering the recovery of natural shellfish beds worldwide, and they are a key taxon for understanding intracellular parasitism adaptations. The ability to propagate the parasite in liquid media, in the absence of the host, has been crucial for improving understanding of its biology; however, alternative techniques to grow the parasite are needed to explore other basic aspects of the Perkinsus spp. biology. We optimized a DME: Ham's F12-5% FBS- containing solid agar medium for plating Perkinsus marinus. This solid medium supported trophozoite propagation both by binary fission and schizogony. Colonies were visible to the naked eye 17 days after plating. We tested the suitability of this method for several applications, including the following: 1) Subcloning P. marinus isolates: single discrete P. marinus colonies were obtained from DME: Ham's F12-5% FBS- 0.75% agar plates, which could be further propagated in liquid medium; 2) Subcloning engineered Perkinsus mediterraneus MOE[MOE]: GFP by streaking cultures on plates; 3) Chemical susceptibility: Infusing the DME: Ham's F12-5% FBS- 0.75% agar plates with triclosan resulted in inhibition of the parasite propagation in a dose-dependent manner. Altogether, our plating method has the potential for becoming a key tool for investigating diverse aspects of Perkinsus spp. biology, developing new molecular tools, and for biotechnological applications.

  1. Predicting the growth situation of Pseudomonas aeruginosa on agar plates and meat stuffs using gas sensors

    NASA Astrophysics Data System (ADS)

    Gu, Xinzhe; Sun, Ye; Tu, Kang; Dong, Qingli; Pan, Leiqing

    2016-12-01

    A rapid method of predicting the growing situation of Pseudomonas aeruginosa is presented. Gas sensors were used to acquire volatile compounds generated by P. aeruginosa on agar plates and meat stuffs. Then, optimal sensors were selected to simulate P. aeruginosa growth using modified Logistic and Gompertz equations by odor changes. The results showed that the responses of S8 or S10 yielded high coefficients of determination (R2) of 0.89–0.99 and low root mean square errors (RMSE) of 0.06–0.17 for P. aeruginosa growth, fitting the models on the agar plate. The responses of S9, S4 and the first principal component of 10 sensors fit well with the growth of P. aeruginosa inoculated in meat stored at 4 °C and 20 °C, with R2 of 0.73–0.96 and RMSE of 0.25–1.38. The correlation coefficients between the fitting models, as measured by electronic nose responses, and the colony counts of P. aeruginosa were high, ranging from 0.882 to 0.996 for both plate and meat samples. Also, gas chromatography–mass spectrometry results indicated the presence of specific volatiles of P. aeruginosa on agar plates. This work demonstrated an acceptable feasibility of using gas sensors—a rapid, easy and nondestructive method for predicting P. aeruginosa growth.

  2. Predicting the growth situation of Pseudomonas aeruginosa on agar plates and meat stuffs using gas sensors

    PubMed Central

    Gu, Xinzhe; Sun, Ye; Tu, Kang; Dong, Qingli; Pan, Leiqing

    2016-01-01

    A rapid method of predicting the growing situation of Pseudomonas aeruginosa is presented. Gas sensors were used to acquire volatile compounds generated by P. aeruginosa on agar plates and meat stuffs. Then, optimal sensors were selected to simulate P. aeruginosa growth using modified Logistic and Gompertz equations by odor changes. The results showed that the responses of S8 or S10 yielded high coefficients of determination (R2) of 0.89–0.99 and low root mean square errors (RMSE) of 0.06–0.17 for P. aeruginosa growth, fitting the models on the agar plate. The responses of S9, S4 and the first principal component of 10 sensors fit well with the growth of P. aeruginosa inoculated in meat stored at 4 °C and 20 °C, with R2 of 0.73–0.96 and RMSE of 0.25–1.38. The correlation coefficients between the fitting models, as measured by electronic nose responses, and the colony counts of P. aeruginosa were high, ranging from 0.882 to 0.996 for both plate and meat samples. Also, gas chromatography–mass spectrometry results indicated the presence of specific volatiles of P. aeruginosa on agar plates. This work demonstrated an acceptable feasibility of using gas sensors—a rapid, easy and nondestructive method for predicting P. aeruginosa growth. PMID:27941841

  3. Enhancing Bioaerosol Sampling by Andersen Impactors Using Mineral-Oil-Spread Agar Plate

    PubMed Central

    Xu, Zhenqiang; Wei, Kai; Wu, Yan; Shen, Fangxia; Chen, Qi; Li, Mingzhen; Yao, Maosheng

    2013-01-01

    As a bioaerosol sampling standard, Andersen type impactor is widely used since its invention in 1950s, including the investigation of the anthrax attacks in the United States in 2001. However, its related problems such as impaction and desiccation stress as well as particle bounce have not been solved. Here, we improved its biological collection efficiencies by plating a mineral oil layer (100 µL) onto the agar plate. An Andersen six-stage sampler and a BioStage impactor were tested with mineral-oil-spread agar plates in collecting indoor and outdoor bacterial and fungal aerosols. The effects of sampling times (5, 10 and 20 min) were also studied using the BioStage impactor when sampling environmental bioaerosols as well as aerosolized Bacillus subtilis (G+) and Escherichia coli (G-). In addition, particle bounce reduction by mineral-oil-plate was also investigated using an optical particle counter (OPC). Experimental results revealed that use of mineral-oil-spread agar plate can substantially enhance culturable bioaerosol recoveries by Andersen type impactors (p-values<0.05). The recovery enhancement was shown to depend on bioaerosol size, type, sampling time and environment. In general, more enhancements (extra 20%) were observed for last stage of the Andersen six-stage samplers compared to the BioStage impactor for 10 min sampling. When sampling aerosolized B. subtilis, E. coli and environmental aerosols, the enhancement was shown to increase with increasing sampling time, ranging from 50% increase at 5 min to ∼100% at 20 min. OPC results indicated that use of mineral oil can effectively reduce the particle bounce with an average of 66% for 10 min sampling. Our work suggests that enhancements for fungal aerosols were primarily attributed to the reduced impaction stress, while for bacterial aerosols reduced impaction, desiccation and particle bounce played major roles. The developed technology can readily enhance the agar-based techniques including those high

  4. Enhancing bioaerosol sampling by Andersen impactors using mineral-oil-spread agar plate.

    PubMed

    Xu, Zhenqiang; Wei, Kai; Wu, Yan; Shen, Fangxia; Chen, Qi; Li, Mingzhen; Yao, Maosheng

    2013-01-01

    As a bioaerosol sampling standard, Andersen type impactor is widely used since its invention in 1950s, including the investigation of the anthrax attacks in the United States in 2001. However, its related problems such as impaction and desiccation stress as well as particle bounce have not been solved. Here, we improved its biological collection efficiencies by plating a mineral oil layer (100 µL) onto the agar plate. An Andersen six-stage sampler and a BioStage impactor were tested with mineral-oil-spread agar plates in collecting indoor and outdoor bacterial and fungal aerosols. The effects of sampling times (5, 10 and 20 min) were also studied using the BioStage impactor when sampling environmental bioaerosols as well as aerosolized Bacillus subtilis (G+) and Escherichia coli (G-). In addition, particle bounce reduction by mineral-oil-plate was also investigated using an optical particle counter (OPC). Experimental results revealed that use of mineral-oil-spread agar plate can substantially enhance culturable bioaerosol recoveries by Andersen type impactors (p-values<0.05). The recovery enhancement was shown to depend on bioaerosol size, type, sampling time and environment. In general, more enhancements (extra 20%) were observed for last stage of the Andersen six-stage samplers compared to the BioStage impactor for 10 min sampling. When sampling aerosolized B. subtilis, E. coli and environmental aerosols, the enhancement was shown to increase with increasing sampling time, ranging from 50% increase at 5 min to ∼100% at 20 min. OPC results indicated that use of mineral oil can effectively reduce the particle bounce with an average of 66% for 10 min sampling. Our work suggests that enhancements for fungal aerosols were primarily attributed to the reduced impaction stress, while for bacterial aerosols reduced impaction, desiccation and particle bounce played major roles. The developed technology can readily enhance the agar-based techniques including those high

  5. Simulation of Bacillus subtilis biofilm growth on agar plate by diffusion-reaction based continuum model

    NASA Astrophysics Data System (ADS)

    Zhang, Xianlong; Wang, Xiaoling; Nie, Kai; Li, Mingpeng; Sun, Qingping

    2016-08-01

    Various species of bacteria form highly organized spatially-structured aggregates known as biofilms. To understand how microenvironments impact biofilm growth dynamics, we propose a diffusion-reaction continuum model to simulate the formation of Bacillus subtilis biofilm on an agar plate. The extended finite element method combined with level set method are employed to perform the simulation, numerical results show the quantitative relationship between colony morphologies and nutrient depletion over time. Considering that the production of polysaccharide in wild-type cells may enhance biofilm spreading on the agar plate, we inoculate mutant colony incapable of producing polysaccharide to verify our results. Predictions of the glutamate source biofilm’s shape parameters agree with the experimental mutant colony better than that of glycerol source biofilm, suggesting that glutamate is rate limiting nutrient for Bacillus subtilis biofilm growth on agar plate, and the diffusion-limited is a better description to the experiment. In addition, we find that the diffusion time scale is of the same magnitude as growth process, and the common-employed quasi-steady approximation is not applicable here.

  6. Agar plate freezing assay for the in situ selection of transformed ice nucleating bacteria.

    PubMed

    Anastassopoulos, Elias

    2006-10-01

    An agar plate freezing assay is described based on the incorporation of fluorescein dye in agar medium. Upon addition of fluorescein the medium becomes transparent. This facilitates the monitoring of the ice nucleation event in vivo and the subsequent in situ selection of transformed ice nucleating bacteria. In comparison with known assays for the screening of transformants, the proposed assay is very accurate and reproducible. It may be applied in environmental samples screening for ice nucleating organisms, or in cDNA or genomic libraries for identifying novel ice nucleation genes. It may also prove useful in comparative studies of the ice nucleation activity, e.g. in directed evolution experiments involving ice nucleation genes.

  7. Visualization of Biosurfactant Film Flow in a Bacillus subtilis Swarm Colony on an Agar Plate

    PubMed Central

    Kim, Kyunghoon; Kim, Jung Kyung

    2015-01-01

    Collective bacterial dynamics plays a crucial role in colony development. Although many research groups have studied the behavior of fluidic swarm colonies, the detailed mechanics of its motion remains elusive. Here, we developed a visualization method using submicron fluorescent beads for investigating the flow field in a thin layer of fluid that covers a Bacillus subtilis swarm colony growing on an agar plate. The beads were initially embedded in the agar plate and subsequently distributed spontaneously at the upper surface of the expanding colony. We conducted long-term live cell imaging of the B. subtilis colony using the fluorescent tracers, and obtained high-resolution velocity maps of microscale vortices in the swarm colony using particle image velocimetry. A distinct periodic fluctuation in the average speed and vorticity of flow in swarm colony was observed at the inner region of the colony, and correlated with the switch between bacterial swarming and growth phases. At the advancing edge of the colony, both the magnitudes of velocity and vorticity of flow in swarm colony were inversely correlated with the spreading speed of the swarm edge. The advanced imaging tool developed in this study would facilitate further understanding of the effect of micro vortices in swarm colony on the collective dynamics of bacteria. PMID:26343634

  8. Evaluation of the Granada agar plate for detection of vaginal and rectal group B streptococci in pregnant women.

    PubMed

    Gil, E G; Rodríguez, M C; Bartolomé, R; Berjano, B; Cabero, L; Andreu, A

    1999-08-01

    Granada medium was evaluated for the detection of group B streptococci (GBS) in vaginal and rectal swabs compared with selective Columbia blood agar and selective Lim broth. From May 1996 to March 1998, 702 pregnant women (35 to 37 weeks of gestation) participated in this three-phase study; 103 (14.7%) of these women carried GBS. In the first phase of the experiment (n = 273 women), vaginorectal specimens were collected on the same swab; the sensitivities of Granada tube, selective Columbia blood agar, and Lim broth were 31.4, 94.3, and 74.3%, respectively. In the second and third phases (n = 429 women), vaginal and rectal specimens were collected separately; the sensitivities of Granada plate, selective Columbia blood agar, and Lim broth (subcultured at 4 h on selective Columbia agar in the second phase and at 18 to 24 h in Granada plate in the third phase) were 91.1, 83.9, and 75%, respectively, in the second phase and 88.5, 90.4, and 63.5%, respectively, in the third phase. There were no statistically significant differences in GBS recovery between the Granada agar plate and selective Columbia blood agar, but the Granada plate provided a clear advantage; the characteristic red-orange colonies produced overnight by GBS can be identified by the naked eye and is so specific that further identification is unnecessary. The use of the Granada tube and Lim broth did not result in increased isolation of GBS. In conclusion, the Granada agar plate is highly sensitive for detecting GBS in vaginal and rectal swabs from pregnant women and can provide results in 18 to 24 h.

  9. Evaluation of the Granada Agar Plate for Detection of Vaginal and Rectal Group B Streptococci in Pregnant Women

    PubMed Central

    Gil, E. García; Rodríguez, M. C.; Bartolomé, R.; Berjano, B.; Cabero, L.; Andreu, A.

    1999-01-01

    Granada medium was evaluated for the detection of group B streptococci (GBS) in vaginal and rectal swabs compared with selective Columbia blood agar and selective Lim broth. From May 1996 to March 1998, 702 pregnant women (35 to 37 weeks of gestation) participated in this three-phase study; 103 (14.7%) of these women carried GBS. In the first phase of the experiment (n = 273 women), vaginorectal specimens were collected on the same swab; the sensitivities of Granada tube, selective Columbia blood agar, and Lim broth were 31.4, 94.3, and 74.3%, respectively. In the second and third phases (n = 429 women), vaginal and rectal specimens were collected separately; the sensitivities of Granada plate, selective Columbia blood agar, and Lim broth (subcultured at 4 h on selective Columbia agar in the second phase and at 18 to 24 h in Granada plate in the third phase) were 91.1, 83.9, and 75%, respectively, in the second phase and 88.5, 90.4, and 63.5%, respectively, in the third phase. There were no statistically significant differences in GBS recovery between the Granada agar plate and selective Columbia blood agar, but the Granada plate provided a clear advantage; the characteristic red-orange colonies produced overnight by GBS can be identified by the naked eye and is so specific that further identification is unnecessary. The use of the Granada tube and Lim broth did not result in increased isolation of GBS. In conclusion, the Granada agar plate is highly sensitive for detecting GBS in vaginal and rectal swabs from pregnant women and can provide results in 18 to 24 h. PMID:10405415

  10. Trace Amounts of Furan-2-Carboxylic Acids Determine the Quality of Solid Agar Plates for Bacterial Culture

    PubMed Central

    Hara, Shintaro; Isoda, Reika; Tahvanainen, Teemu; Hashidoko, Yasuyuki

    2012-01-01

    Background Many investigators have recognised that a significant proportion of environmental bacteria exist in a viable but non-culturable state on agar plates, and some researchers have also noticed that some of such bacteria clearly recover their growth on matrices other than agar. However, the reason why agar is unsuitable for the growth of some bacteria has not been addressed. Methodology/Principal Findings According to the guide of a bioassay for swarming inhibition, we identified 5-hydroxymethylfuran-2-carboxylic acid (5-HMFA) and furan-2-carboxylic acid (FA) as factors that inhibit bacterial swarming and likely inhibit extracellular polysaccharide production on agar. The furan-2-carboxylic acids 5-HMFA and FA effectively inhibited the swarming and swimming of several environmental bacteria at concentrations of 1.8 and 2.3 µg L−1 (13 and 21 nmol L−1), respectively, which are equivalent to the concentrations of these compounds in 0.3% agar. On Luria-Bertani (LB) plates containing 1.0% agar that had been previously washed with MeOH, a mixture of 5-HMFA and FA in amounts equivalent to their original concentrations in the unwashed agar repressed the swarming of Escherichia coli K12 strain W3110, a representative swarming bacterium. Conclusions/Significance Agar that contains trace amounts of 5-HMFA and FA inhibits the proliferation of some slow-growing or difficult-to-culture bacteria on the plates, but it is useful for single colony isolation due to the ease of identification of swarmable bacteria as the non-swarmed colonies. PMID:22848437

  11. Root-Contact/Pressure-Plate Assembly For Hydroponic System

    NASA Technical Reports Server (NTRS)

    Morris, Carlton E.; Loretan, Philip A.; Bonsi, Conrad K.; Hill, Walter A.

    1994-01-01

    Hydroponic system includes growth channels equipped with rootcontact/pressure-plate assemblies. Pump and associated plumbing circulate nutrient liquid from reservoir, along bottom of growth channels, and back to reservoir. Root-contact/pressure-plate assembly in each growth channel stimulates growth of roots by applying mild contact pressure. Flat plate and plate connectors, together constitute pressure plate, free to move upward to accommodate growth of roots. System used for growing sweetpotatoes and possibly other tuber and root crops.

  12. Solvent-tolerance of fungi located on an interface between an agar plate and an organic solvent.

    PubMed

    Oda, Shinobu; Sugitani, Ayaka; Ohashi, Shinichi

    2014-01-01

    While 6 by 20 of type culture fungi could grow on an interface between organic solvent (log P, 4.12) and agar plate, 13 by 20 of strains could form a large colony after the removal of more toxic solvent, such as styrene (log P, 2.95) and tert-butyl acetate (log P, 1.76) because of viability of spores on the interface.

  13. [Analysis of bactericidal material generated by electrical devices advertising bactericidal ability against bacteria on the agar gel plates].

    PubMed

    Nishimura, Hidekazu

    2012-11-01

    Several Japanese companies sell electrical devices advertised as effective in inactivating viruses and killing bacteria by releasing special materials, e.g., Plasmacluster ions, Nanoe particle and minus ions, into the air. These companies claim that their devices killed bacteria on plates in their own experiments. We tested device effectiveness using the same experiments from the Plasmacluster ioniser SHARP Co., Japan, the Nanoe generator Panasonic Co., Japan, and the Vion KING JIM Co., Japan, to test their advertising claims. Bactericidal ability on agar plate was tested, using Staphylococcus aureus, Pseudomonas aeruginosa, Bacillus cereus, and Enterococcus faecalis as follows: the medium containing a certain amount of each bacterium was put onto an agar plate and smeared. Plates were kept in a closed chamber (inner volume 14.4 m3) or a glove box (inner volume 0.2 m), with one of the devices run for 2 hours. Plates not exposed to any device were used as controls. Each plate was retrieved and put in an incubator to count the number of bacterial colonies formed on the plate. There was no significant difference in the number of colonies on plates exposed to devices compared to control, in the number for all devices, or in all bacteria tested in experiments in the 14.4 m3 chamber. These results strongly suggest that these devices have almost no bactericidal effect, at least in space exceeding this volume. Colony formation was suppressed in the glove box in all devices and in all bacteria tested except P. aeruginosa, although the degree of suppression differed among experiments. The colony formation suppression mechanism was analyzed, and indicated that:colony formation did not change even after the removal of Plasmacluster ions, Nanoe particles, or negative ions from the air, while colony formation was decreased drastically by the removal of ozone from space, which was revealed to be generated inevitably during device operation. These results strongly suggest that the

  14. Broth and agar hop-gradient plates used to evaluate the beer-spoilage potential of Lactobacillus and Pediococcus isolates.

    PubMed

    Haakensen, M; Schubert, A; Ziola, B

    2009-03-15

    Identification of the beer-spoilage Lactobacillus and Pediococcus bacteria has largely taken two approaches; identification of spoilage-associated genes or identification of specific species of bacteria regardless of ability to grow in beer. The problem with these two approaches is that they are either overly inclusive (i.e., detect all bacteria of a given species regardless of spoilage potential) or overly selective (i.e., rely upon individual, putative spoilage-associated genes). Our goal was to design a method to assess the ability of Lactobacillus and Pediococcus to spoil beer that is independent of speciation or genetic background. In searching for a method by which to differentiate between beer-spoilage bacteria and bacteria that cannot grow in beer, we explored the ability of lactobacilli and pediococci isolates to grow in the presence of varying concentrations of hop-compounds and ethanol in broth medium versus on agar medium. The best method for differentiating between bacteria that can grow in beer and bacteria that do not pose a threat as beer-spoilage organisms was found to be a hop-gradient agar plate containing ethanol. This hop-gradient agar plate technique provides a rapid and simple solution to the dilemma of assessing the ability of Lactobacillus and Pediococcus isolates to grow in beer, and provides new insights into the different strategies used by these bacteria to survive under the stringent conditions of beer.

  15. Aurelia aurita (Cnidaria) Oocytes' Contact Plate Structure and Development

    PubMed Central

    Adonin, Leonid S.; Shaposhnikova, Tatyana G.; Podgornaya, Olga

    2012-01-01

    One of the A. aurita medusa main mesoglea polypeptides, mesoglein, has been described previously. Mesoglein belongs to ZP-domain protein family and therefore we focused on A.aurita oogenesis. Antibodies against mesoglein (AB RA47) stain the plate in the place where germinal epithelium contacts oocyte on the paraffin sections. According to its position, we named the structure found the “contact plate”. Our main instrument was AB against mesoglein. ZP-domain occupies about half of the whole amino acid sequence of the mesoglein. Immunoblot after SDS-PAGE and AU-PAGE reveals two charged and high Mr bands among the female gonad germinal epithelium polypeptides. One of the gonads' polypeptides Mr corresponds to that of mesogleal cells, the other ones' Mr is higher. The morphological description of contact plate formation is the subject of the current work. Two types of AB RA47 positive granules were observed during progressive oogenesis stages. Granules form the contact plate in mature oocyte. Contact plate of A.aurita oocyte marks its animal pole and resembles Zona Pellucida by the following features: (1) it attracts spermatozoids; (2) the material of the contact plate is synthesized by oocyte and stored in granules; (3) these granules and the contact plate itself contain ZP domain protein(s); (4) contact plate is an extracellular structure made up of fiber bundles similar to those of conventional Zona Pellucida. PMID:23185235

  16. Contact resistance prediction and structure optimization of bipolar plates

    NASA Astrophysics Data System (ADS)

    Zhou, P.; Wu, C. W.; Ma, G. J.

    The objective of this work is to investigate the effect of clamping force on the interfacial contact resistance and the porosity of the gas diffusion layer (GDL) in a proton exchange membrane fuel cell (PEMFC). An optimal rib shape for the bipolar plate is developed to analyze the electrical contact resistance. We found that the electrical contact resistance is determined by both the clamping force and the contact pressure distribution. A minimum contact resistance can be obtained in the case of a constant contact pressure distribution. The porosity of the GDLs underneath the rib of the bipolar plate decreases with increasing the clamping force, and the void volume is changed with the deformation of the GDLs. It is found that there exists an optimal rib width of the bipolar plates to obtain a reasonable combination of low interfacial contact resistance and good porosity for the GDL.

  17. Rapid identification of Candida albicans by using Albicans ID and fluoroplate agar plates.

    PubMed Central

    Rousselle, P; Freydiere, A M; Couillerot, P J; de Montclos, H; Gille, Y

    1994-01-01

    Two commercially available agar media, Albicans ID and Fluoroplate, that use a chromogenic or a fluorogenic substrate for the detection and identification of Candida albicans were evaluated. From 1,006 clinical samples containing 723 yeast strains, 352 C. albicans strains were detected with either of the two media. The sensitivity of each of the two media was 93.8% and the specificity was 98.6%, with five false-positive reactions for Candida tropicalis and no false-negative reactions. PMID:7883894

  18. Correlation between Agar Plate Screening and Solid-State Fermentation for the Prediction of Cellulase Production by Trichoderma Strains

    PubMed Central

    Florencio, Camila; Couri, Sonia; Farinas, Cristiane Sanchez

    2012-01-01

    The viability of converting biomass into biofuels and chemicals still requires further development towards the reduction of the enzyme production costs. Thus, there is a growing demand for the development of efficient procedures for selection of cellulase-producing microorganisms. This work correlates qualitative screening using agar plate assays with quantitative measurements of cellulase production during cultivation under solid-state fermentation (SSF). The initial screening step consisted of observation of the growth of 78 preselected strains of the genus Trichoderma on plates, using microcrystalline cellulose as carbon source. The 49 strains that were able to grow on this substrate were then subjected to a second screening step using the Congo red test. From this test it was possible to select 10 strains that presented the highest enzymatic indices (EI), with values ranging from 1.51 to 1.90. SSF cultivations using sugarcane bagasse and wheat bran as substrates were performed using selected strains. The CG 104NH strain presented the highest EGase activity (25.93 UI·g−1). The EI results obtained in the screening procedure using plates were compared with cellulase production under SSF. A correlation coefficient (R2) of 0.977 was obtained between the Congo red test and SSF, demonstrating that the two methodologies were in good agreement. PMID:23227312

  19. Contact stresses in pin-loaded orthotropic plates

    NASA Technical Reports Server (NTRS)

    Hyer, M. W.; Klang, E. C.

    1984-01-01

    The effects of pin elasticity, friction, and clearance on the stresses near the hole in a pin-loaded orthotropic plate are described. The problem is modeled as a contact elasticity problem using complex variable theory, the pin and the plate being two elastic bodies interacting through contact. This modeling is in contrast to previous works which assumed that the pin is rigid or that it exerts a known cosinusoidal radial traction on the hole boundary. Neither of these approaches explicitly involves a pin. A collocation procedure and iteration were used to obtain numerical results for a variety of plate and pin elastic properties and various levels of friction and clearance. Collocation was used to enforce the boundary and iteration was used to find the contact and no-slip regions on the boundary. Details of the numerical scheme are discussed.

  20. Comparison of agar-based methods for the isolation and enumeration of heterotrophic bacteria with the new multidose IDEXX SimPlate method.

    PubMed

    Vulindlu, M; Charlett, A; Surman, S; Lee, J V

    2004-01-01

    Pour and spread plates are the conventional methods of choice for the isolation and enumeration of heterotrophic microorganisms in treated water supplies. The tests are performed at 22 degrees C and 37 degrees C for 72 h and 48 h respectively. Counts at 22 degrees C are associated with pollution of water systems from external sources, while counts at 37 degrees C are used as an indication of treatment plant performance and the deterioration of the general quality of water. Conventional methods using Yeast Extract Agar for a pour plate and R2A agar for a spread plate were compared with the multidose IDEXX SimPlate method for the isolation and enumeration of heterotrophic bacteria in water. SimPlate gave a significantly higher count on average than the conventional methods. The R2A method showed the next highest count, being significantly higher than Yeast Extract Agar. In addition, unlike the pour and spread plate methods, SimPlate was easier to use, reduced labour, and the test results were far easier to read.

  1. Evaluation of heterotrophic plate and chromogenic agar colony counting in water quality laboratories

    PubMed Central

    Hallas, Gary; Monis, Paul

    2015-01-01

    The enumeration of bacteria using plate-based counts is a core technique used by food and water microbiology testing laboratories. However, manual counting of bacterial colonies is both time and labour intensive, can vary between operators and also requires manual entry of results into laboratory information management systems, which can be a source of data entry error. An alternative is to use automated digital colony counters, but there is a lack of peer-reviewed validation data to allow incorporation into standards. We compared the performance of digital counting technology (ProtoCOL3) against manual counting using criteria defined in internationally recognized standard methods. Digital colony counting provided a robust, standardized system suitable for adoption in a commercial testing environment. The digital technology has several advantages:•Improved measurement of uncertainty by using a standard and consistent counting methodology with less operator error.•Efficiency for labour and time (reduced cost).•Elimination of manual entry of data onto LIMS.•Faster result reporting to customers. PMID:26649275

  2. Evaluation of heterotrophic plate and chromogenic agar colony counting in water quality laboratories.

    PubMed

    Hallas, Gary; Monis, Paul

    2015-01-01

    The enumeration of bacteria using plate-based counts is a core technique used by food and water microbiology testing laboratories. However, manual counting of bacterial colonies is both time and labour intensive, can vary between operators and also requires manual entry of results into laboratory information management systems, which can be a source of data entry error. An alternative is to use automated digital colony counters, but there is a lack of peer-reviewed validation data to allow incorporation into standards. We compared the performance of digital counting technology (ProtoCOL3) against manual counting using criteria defined in internationally recognized standard methods. Digital colony counting provided a robust, standardized system suitable for adoption in a commercial testing environment. The digital technology has several advantages:•Improved measurement of uncertainty by using a standard and consistent counting methodology with less operator error.•Efficiency for labour and time (reduced cost).•Elimination of manual entry of data onto LIMS.•Faster result reporting to customers.

  3. Subduction Zone Diversity and Nature of the Plate Contact

    NASA Astrophysics Data System (ADS)

    Defranco, R.; Govers, R.; Wortel, R.

    2008-12-01

    We recently showed that the overall dynamics of subduction and initial collision depends on whether the plate contact is a fault or a channel. Here, we combine results of our numerical experiments with a re-analysis of published observations. Overall, our synthesis connects seismic moment release with back-arc deformation and tectonic processes at the margin. It leads us to identify four classes of subduction zones. The first two classes results directly from our numerical experiments. In class 1, subduction zones are characterized by a plate contact that is largely fault-like with an accretionary margin. In class 2, the plate contacts are largely channel-type and have an erosive margin. Class 3, where the plate contact is entirely channel-like, consists of accretionary margins with a high sediment supply. Subduction zones of class 4, mostly characterized by an erosive convergent margin (northern Chili, Peru, Honshu and Kuril), are more complicated. They can be explained by incorporating regional observations.

  4. Evaluation of an immunochromatographic assay for direct identification of thermostable direct hemolysin-producing Vibrio parahaemolyticus colonies on selective agar plates.

    PubMed

    Kawatsu, Kentaro; Sakata, Junko; Yonekita, Taro; Kumeda, Yuko

    2015-12-01

    We evaluated the utility of an immunochromatographic assay (NH IC TDH) in identifying thermostable direct hemolysin (TDH)-producing Vibrio parahaemolyticus colonies on selective agar plates. The sensitivity of the NH IC TDH assay was 100% (189 samples) and its specificity was 100% (41 samples) compared with the presence of tdh.

  5. Differentiating non-0157:H7 STEC serogroups from ground beef plated on agar media by hyperspetral imaging

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Introduction: The development of an assay to detect and confirm a positive non-O157:H7 isolate is challenging when mixed morphologically results are obtained from the serogroups growing on Rainbow agar. Rainbow agar is only claimed by the manufacturer to be very specific for E.coli O157:H7 strain...

  6. Pore corrosion model for gold-plated copper contacts.

    SciTech Connect

    Moffat, Harry K.; Sun, Amy Cha-Tien; Glauner, Carly S.; Enos, David George

    2005-04-01

    The goal of this study is to model the electrical response of gold plated copper electrical contacts exposed to a mixed flowing gas stream consisting of air containing 10ppb H2S at 30 C and a relative humidity of 70%. This environment accelerates the attack normally observed in a light industrial environment (essentially a simplified version of the Battelle class 2 environment). Corrosion rates were quantified by measuring the corrosion site density, size distribution, and the macroscopic electrical resistance of the aged surface as a function of exposure time. A pore corrosion numerical model was used to predict both the growth of copper sulfide corrosion product which blooms through defects in the gold layer and the resulting electrical contact resistance of the aged surface. Assumptions about the distribution of defects in the noble metal plating and the mechanism for how corrosion blooms affect electrical contact resistance were needed to close the numerical model. Comparisons are made to the experimentally observed number density of corrosion sites, the size distribution of corrosion product blooms, and the cumulative probability distribution of the electrical contact resistance. Experimentally, the bloom site density increases as a function of time, whereas the bloom size distribution remains relatively independent of time. These two effects are included in the numerical model by adding a corrosion initiation probability proportional to the surface area along with a probability for bloom-growth extinction proportional to the corrosion product bloom volume. The cumulative probability distribution of electrical resistance becomes skewed as exposure time increases. While the electrical contact resistance increases as a function of time for a fraction of the bloom population, the median value remains relatively unchanged. In order to model this behavior, the resistance calculated for large blooms has been weighted more heavily.

  7. Antiserum-agar plate method for simultaneous detection and direct isolation of Legionella species in clinical and environmental specimens.

    PubMed Central

    Janssen, W A; Hedlund, K W

    1982-01-01

    Colonies of Legionella pneumophila serotypes 1 through 6, L. micdadei, L. bozemanii, L. dumoffii, and L. gormanii, which were developed on filtered yeast extract agar containing polyvalent antiserum, were surrounded by distinct, specific precipitin rings. Images PMID:7050153

  8. Identification of Brucella by MALDI-TOF Mass Spectrometry. Fast and Reliable Identification from Agar Plates and Blood Cultures

    PubMed Central

    Ferreira, Laura; Vega Castaño, Silvia; Sánchez-Juanes, Fernando; González-Cabrero, Sandra; Menegotto, Fabiola; Orduña-Domingo, Antonio

    2010-01-01

    Background MALDI-TOF mass spectrometry (MS) is a reliable method for bacteria identification. Some databases used for this purpose lack reference profiles for Brucella species, which is still an important pathogen in wide areas around the world. We report the creation of profiles for MALDI-TOF Biotyper 2.0 database (Bruker Daltonics, Germany) and their usefulness for identifying brucellae from culture plates and blood cultures. Methodology/Principal Findings We created MALDI Biotyper 2.0 profiles for type strains belonging to B. melitensis biotypes 1, 2 and 3; B. abortus biotypes 1, 2, 5 and 9; B. suis, B. canis, B ceti and B. pinnipedialis. Then, 131 clinical isolates grown on plate cultures were used in triplicate to check identification. Identification at genus level was always correct, although in most cases the three replicates reported different identification at species level. Simulated blood cultures were performed with type strains belonging to the main human pathogenic species (B. melitensis, B. abortus, B. suis and B. canis), and studied by MALDI-TOF MS in triplicate. Identification at genus level was always correct. Conclusions/Significance MALDI-TOF MS is reliable for Brucella identification to the genus level from culture plates and directly from blood culture bottles. PMID:21151913

  9. Effectiveness of nickel plating in inhibiting atmospheric corrosion of copper alloy contacts

    SciTech Connect

    Ernest, T.; Sorensen, R.; Guilinger, T.

    1997-12-31

    A series of tests was run to determine the effect of Ni plating thickness on connector contact resistance. Copper coupons were plated with an electrolytic nickel strike followed by electroless nickel to produce Ni layers of 10, 20, 55 and 100 {micro}in. The coupons were then exposed to a simulated industrial environment. Pore corrosion was observed after the exposure, which correlated with Ni thickness. In a second series of tests, beryllium-copper four-tine contacts with 50 {micro}in of gold plate over electrolytic nickel strike/electroless-nickel plates of varying thickness were exposed the same corrosive environment. Contact resistance of mated pairs was monitored over a two-month period. The degradation in contact resistance correlated with the Ni thickness used in the connectors.

  10. Ni/Cu/Ag plated contacts: A study of resistivity and contact adhesion for crystalline-Si solar cells

    NASA Astrophysics Data System (ADS)

    ur Rehman, Atteq; Lee, Sang Hee; Bhopal, Muhammad Fahad; Lee, Soo Hong

    2016-07-01

    Ni/Cu/Ag plated contacts were examined as an alternate to Ag screen printed contacts for silicon (Si) solar cell metallization. To realize a reliable contact for industrial applications, the contact resistance and its adhesion to Si substrates were evaluated. Si surface roughness by picosecond (ps) laser ablation of silicon-nitride (SiNx) antireflection coating (ARC) was done in order to prepare the patterns. The sintering process after Ni/Cu/Ag full metallization in the form of the post-annealing process was applied to investigate the contact resistivity and adhesion. A very low contact resistivity of approximately 0.5 mΩcm2 has been achieved with measurements made by the transfer length method (TLM). Thin finger lines of about 26 μm wide and a line resistance of 0.51 Ω/cm have been realized by plating technology. Improved contact adhesion by combining the ps-laser-ablation and post-annealing process has been achieved. We have shown the peel-off strengths >1 N/mm with a higher average adhesion of 1.9 N/mm. Our pull-tab adhesion tests demonstrate excellent strength well above the wafer breakage force. [Figure not available: see fulltext.

  11. Recovery of impact contact forces of composite plates using fiber optic sensors and neural networks

    NASA Astrophysics Data System (ADS)

    Akhavan, Farhad; Watkins, Steve E.; Chandrashekhara, K.

    1996-10-01

    Real-time determination of contact forces due to impact on composite plates is necessary for on-line impact damage detection and identification. We demonstrate the use of fiber optic strain sensor data as inputs to a neural network to obtain contact force history. An experimental study is conducted to determine the in-plane strains of a clamped graphite/epoxy composite plate upon low-velocity impacts using surface mounted extrinsic Fabry-Perot interferometric strain sensors. The plate is impacted with a semi-spherical impactor with various impact energies using the drop-weight technique. The impacts did not produce apparent damage in the composite plates. The significant features of the strain and contact force response are contact duration, peak strain, strain rise-time and full-width at half maximum. We have designed and built an instrumented drop-weight impact tower to facilitate the measurement of contact force during an impact event. The impact head assembly incorporates a load cell to measure the contact forces experimentally. The load cell data is used to train a three-layer feedforward neural network which utilizes the back-propagation algorithm. The output of the neural network simulation is the impact contact force history and the inputs are fiber optic sensor data in two different locations and time in 10 microsecond intervals. The efficiency and accuracy of the neural network method is discussed. The neural network scheme recovers the impact contact forces without using any complex signal processing techniques.

  12. Evaluation of Thickness Reduction in a Thin Plate Using a Non-Contact Guided Wave Technique

    SciTech Connect

    Song, Won-Joon; Park, Ik-Keun; Kim, Tae-Hyung; Kim, Hyun-Mook; Kim, Yong-Kwon; Cho, Yong-Sang

    2006-03-06

    Ultrasonic guided waves are widely being studied and successfully applied to various non-destructive tests with the advantage of a long range inspection. Recently, non-contact methods are also adopted and combined with the guided wave techniques. In this paper, an advanced technique for the nondestructive detection of thinning defects simulating hidden corrosion in thin plates using non-contact guided waves is presented. The proposed approach uses EMAT(Electro-Magnetic Acoustic Transducer) for the non-contact generation and detection of guided plate waves in aluminum plates. Interesting features of the dispersive behavior in selected wave modes are used for the detection of plate thinning. The experimental results show that the mode cutoff measurements provide a qualitative measurement of thinning defects and change in the mode group velocity can be used as quantitative parameter of thinning depth measurement.

  13. Micro-Structural Study of Fretting Contact Caused by the Difference of the Tin Plating Thickness

    NASA Astrophysics Data System (ADS)

    Ito, Tetsuya; Sawada, Shigeru; Hattori, Yasuhiro; Saitoh, Yasushi; Tamai, Terutaka; Iida, Kazuo

    In recent years, there has been increasing demand to miniaturize wiring harness connectors in automobiles due to the increasing volume of electronic equipment and the reduction of the installation space allocated for the electronic equipment in automobiles for the comfort of the passengers. With this demand, contact failure caused by the fretting corrosion is expected to become a serious problem. In this report, we examined micro-structural observations of fretting contacts of two different tin plating thicknesses using Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM) and so on. Based on the results, we compared the microstructure difference of fretting contact caused by the difference of the tin plating thickness.

  14. Non-Contact Guide for Traveling Continuous Steel Plates in Loop Shaping Part Using Electromagnetic Force

    NASA Astrophysics Data System (ADS)

    Kashiwabara, Ken; Kumagai, Hiroaki; Oshinoya, Yasuo; Ishibashi, Kazuhisa; Kasuya, Hirakazu

    In the factory, the continuous steel plates subjected to iron and steel processes are supported by a series of rollers during processes such as rolling. However, because roller comes in contact with the steel plates, the problem of surface quality deterioration arises. To solve this problem, we develop a non-contact guide for parts of the steel plate at which its traveling direction changes in high-speed traveling by applying an electromagnetic force from the direction of the edge of the steel plate, and experimentally examine the effectiveness of the system. Moreover, when the position of the plate is controlled, it is extremely difficult to determine the mass of the control target. We confirm the suppressive effect of a sliding mode control theory that has robustness in mass variation. The results indicate that the proposed system can be achieved.

  15. The Interpretation of Dynamic Contact Angles Measured by the Wilhelmy Plate Method

    PubMed

    Ramé

    1997-01-01

    We present an analysis for properly interpreting apparent dynamic contact angles measured using the Wilhelmy plate method at low capillary numbers, Ca. This analysis removes the ambiguity in current dynamic measurements which interpret data with the same formula as static measurements. We properly account for all forces, including viscous forces, acting on the plate as it moves into or out of a liquid bath. Our main result, valid at O(1) as Ca --> 0, relates the apparent dynamic contact angle to material-dependent, geometry-independent parameters necessary for describing dynamic wetting of a system. The special case of the apparent contact angle = pi/2 was solved to O(Ca). This O(Ca) solution can guide numerical work necessary for higher Ca's and arbitrary values of the apparent contact angle. These results make the Wilhelmy plate a viable method for determining material parameters for dynamic spreading.

  16. Comparison of the effect on bone healing process of different implants used in minimally invasive plate osteosynthesis: limited contact dynamic compression plate versus locking compression plate

    PubMed Central

    Xue, Zichao; Xu, Haitao; Ding, Haoliang; Qin, Hui; An, Zhiquan

    2016-01-01

    Minimally invasive plate osteosynthesis (MIPO) has been widely accepted because of its satisfactory clinical outcomes. However, the implant construct that works best for MIPO remains controversial. Different plate designs result in different influence mechanisms to blood flow. In this study, we created ulnar fractures in 42 beagle dogs and fixed the fractures using MIPO. The dogs were randomly divided into two groups and were fixed with a limited contact dynamic compression plate (LC-DCP) or a locking compression plate (LCP). Our study showed that with MIPO, there was no significant difference between the LCP and the LC-DCP in terms of fracture fixation, bone formation, or mineralization. Combined with the previous literature, we inferred that the healing process is affected by the quality of fracture reduction more than plate selection. PMID:27885262

  17. Dynamic contact angle of a liquid spreading on a heated plate

    SciTech Connect

    Ripple, D.

    1999-06-01

    An equation determining the steady-state profile of a liquid meniscus advancing or receding across a heated plate is derived. The effects of liquid evaporation, intermolecular interaction with the plate, and thermocapillarity are included. Numerical and analytical estimates of the dynamic contact angle are calculated for water and the refrigerant 1,1,1,2 tetrafluoroethane. The dynamic contact angle depends primarily on three dimensionless parameters: one proportional to the velocity of the interface, one proportional to the rate of evaporation from the surface, and one proportional to the thermal coefficient of the liquid-vapor surface tension.

  18. Contact problem for an elastic reinforcement bonded to an elastic plate

    NASA Technical Reports Server (NTRS)

    Erdogan, F.; Civelek, M. B.

    1973-01-01

    The stiffening layer is treated as an elastic membrane and the base plate is assumed to be an elastic continuum. The bonding between the two materials is assumed to be either one of direct adhesion ro through a thin adhesive layer which is treated as a shear spring. The solution for the simple case in which both the stiffener and the base plate are treated as membranes is also given. The contact stress is obtained for a series of numerical examples. In the direct adhesion case the contact stress becomes infinite at the stiffener ends with a typical square root singularity for the continuum model, and behaving as a delta function for the membrane model. In the case of bonding through an adhesive layer the contact stress becomes finite and continuous along the entire contact area.

  19. Rolling contact fatigue life of chromium ion plated 440C bearing steel

    NASA Technical Reports Server (NTRS)

    Bhat, B. N.; Davis, J. H.

    1985-01-01

    Rolling contact fatigue (RCF) test specimens of heat treated 440C bearing steel were chromium ion plated in thicknesses from 0.1 to 8.0 micron and tested in RCF tester using 700 ksi maximum Hertzian stress. Heavy coatings, greater than about 5 micron in thickness, peeled off or spalled readily, whereas thin coatings, less than 3 micron thick, were tenacious and did not come off. Furthermore, significant improvement in RCF life was obtained with thin chromium ion plated test specimens. The average increase in B10 life was 75% compared with unplated 440C. These preliminary results indicate that ion plating is a promising way to improve bearing life.

  20. Contact problems for a circular plate with sliding fixation at the end face

    NASA Astrophysics Data System (ADS)

    Bazarenko, N. A.

    2014-05-01

    Two mixed elasticity problems of punch indentation into a circular plate placed without clearance in a rigid cylindrical holder with smooth walls are considered. In the first problem, the plate lies without friction on a rigid base, and in the second problem, the plate is rigidly fixed to the base. The problems are solved by a method that was developed for bodies of finite dimensions and is based on the properties of closed systems of orthogonal functions. Each of the problems is reduced to two integral equations, namely, a Volterra integral equation of the first kind for the contact pressure function and a Fredholm integral equation of the first kind for the derivatives of the displacement of the plate upper surface outside the punch. The displacement function is sought as the sum of a trigonometric series and a power function with a root singularity. After truncation, the obtained illposed system of linear algebraic equation has a stable solution. A method for solving Volterra integral equations is given. The contact pressure distribution function and the dimensionless indentation force are determined. Examples of calculation of the plate interaction with the plane punch are given. Contact problems were earlier studied for a rectangle and a circular plate with a stress-free end both without taking account of their fixation [1, 2] and with regard for their fixation [3, 4]. The solution method described here was used to study the interaction of elastic hollow cylinder of finite length with a rigid bandage and a rigid insert [5, 6]. Other papers dealing with contact problems for bodies of finite dimensions, in particular, for a circular plate, should also be mentioned. In these papers, the problems under study were solved by the method of homogeneous solutions [7, 8] and by the method of coupled series-equations [9].

  1. The effect of contact spacing on the efficiency of flat plate solar collector plates

    NASA Astrophysics Data System (ADS)

    Schneider, G. E.; Crha, S.

    1984-01-01

    Rather than use a continuous weld or solder for thermal contact in the attachment of an extended surface to an energy removal tube, attention is given to the use of discontinuous attachment through the uniform distribution of finite regions of contact. This scheme is applied to a solar energy collection system in which it was thought capable of yielding fabrication and reliability improvements. A nondimensional formulation and numerical solution of FEM modeling yields the sensitivity of collector thermal performance to weld-solder joint dimensions. The discontinuous weld is found to significantly degrade system performance in proportion to the fin surface Biot modulus, with the controlling parameter (with respect to weld dimensions) being the perimeter length at the weld location of contact.

  2. Thermal conductance of gold plated metallic contacts at liquid helium temperatures

    NASA Technical Reports Server (NTRS)

    Kittel, Peter; Spivak, Alan L.; Salerno, Louis J.

    1992-01-01

    The thermal conductance of gold plated OFHC copper, 6061-T6 aluminum, free-machining brass, and 304 stainless steel contacts has been measured over the temperature range of 1.6 to 4.2 K, with applied forces from 22 N to 670 N. The contact surfaces were prepared with a 0.8 micron lapped finish prior to gold coating. It was found that for all materials, except stainless steel, the thermal conductance was significantly improved as the result of gold coating the contact surfaces.

  3. A comparison of serial plate agar dilution, Bauer-Kirby disk diffusion, and the Vitek AutoMicrobic system for the determination of susceptibilities of Klebsiella spp., Enterobacter spp., and Pseudomonas aeruginosa to ten antimicrobial agents.

    PubMed

    Fekete, T; Tumah, H; Woodwell, J; Truant, A; Satishchandran, V; Axelrod, P; Kreter, B

    1994-04-01

    The use of rapid, automated technologies for assessment of antimicrobial susceptibility and determination of minimum inhibitory concentrations has been evolving for over a decade. We compared the Vitek AutoMicrobic system and Bauer-Kirby disk diffusion with the National Committee for Clinical Laboratory Standards methods of serial plate agar dilution for qualitative and quantitative susceptibilities of 301 hospital isolates of Klebsiella spp., Enterobacter spp., and Pseudomonas aeruginosa. Antibiotics tested were aztreonam, cefoperazone, ceftazidime, ceftriaxone, ciprofloxacin, gentamicin, imipenem, piperacillin, ticarcillin-clavulanic acid, and tobramycin. Agar dilution and Bauer-Kirby results were more strongly correlated for all three genera than were the results for agar dilution and Vitek. If agar dilution is presumed to be the "gold standard," Bauer-Kirby disk diffusion had only half the number of false susceptibles as did the Vitek. Thus, the Vitek AutoMicrobic system seems to be somewhat less reliable for both qualitative and quantitative measurement of susceptibility and resistance than is Bauer-Kirby disk diffusion.

  4. A refractive tilting-plate technique for measurement of dynamic contact angles.

    PubMed

    Smedley, Gregory T; Coles, Donald E

    2005-06-01

    The contact angle is a critical parameter in liquid interface dynamics ranging from liquid spreading on a solid surface on earth to liquid motion in partially filled containers in space. A refractive tilting-plate technique employing a scanning laser beam is developed to conduct an experimental study of a moving contact line, with the intention of making accurate measurements of the contact angle. The technique shows promise as an accurate and potentially fully automated means to determine the velocity dependence of the contact angle at the intersection of the interface between two transparent fluids with a transparent solid surface. Ray tracing calculations are included to reinforce the measurement concept. The principal experiments were conducted at speeds ranging from 0.05 to 1.00 mm/s, both advancing and receding, using an immiscible liquid pair (nonane/formamide) in contact with glass. The contact angle was found to depend for practical purposes only on the sign of the velocity and not on its magnitude for the range of velocities studied. Other observations revealed a bimodal behavior of the contact line that depends on which liquid first contacts the glass, with resulting drift in the dynamic contact angle with time.

  5. Analytical model development of an eddy-current-based non-contacting steel plate conveyance system

    NASA Astrophysics Data System (ADS)

    Liu, Cheng-Tsung; Lin, Sheng-Yang; Yang, Yung-Yi; Hwang, Chang-Chou

    A concise model for analyzing and predicting the quasi-static electromagnetic characteristics of an eddy-current-based non-contacting steel plate conveyance system has been developed. Confirmed by three-dimensional (3-D) finite element analysis (FEA), adequacy of the analytical model can be demonstrated. Such an effective approach, which can be conveniently used by the potential industries for preliminary system operational performance evaluations, will be essential for designers and on-site engineers.

  6. Operational modal analysis of a rectangular plate using non-contact excitation and measurement

    NASA Astrophysics Data System (ADS)

    Xu, Y. F.; Zhu, W. D.

    2013-09-01

    Operational modal analysis (OMA), or output-only modal analysis, has been extensively developed in the past decades and widely used especially when the input is unknown and difficult to measure. This paper presents a non-contact experimental technique for measuring modal parameters of a rectangular aluminum plate with free boundaries using only the output data, with the intention to apply the technique to turbine blades. OMA is used to analyze both the out-of-plane and in-plane vibrations of the plate in the frequency range of up to 15,000 Hz, which can be an operation frequency range of a turbine blade, under white noise acoustic excitation in a direction of interest. It is shown that OMA can be performed when the types of measurement at the measurement and reference points are different, since the associated cross-correlation functions contain modal characteristics of the test structure. A single-point laser vibrometer and a free-field microphone are used to simultaneously measure the responses of the plate in a non-contact manner, with the microphone measurement serving as the reference. The pressure measured by the microphone near the reference point is shown to be proportional to the normal surface acceleration at the reference point, and the cross power spectral densities obtained by the current test method can be used for modal parameter estimation. A method for measuring the in-plane modes of the plate by shining the laser beam on the plate surface with an incident angle is developed. Experimental modal analysis (EMA) is also performed on the plate using an impact hammer and the laser vibrometer. The measured natural frequencies and mode shapes of the out-of-plane and in-plane modes of the plate using OMA and EMA are compared with those calculated using commercial finite element software. The maximum error between the measured and calculated natural frequencies of the plate is 1.53 percent for the first 18 elastic modes, including 16 out-of-plane and two in

  7. Non-Contact Determination of Antisymmetric Plate Wave Velocity in Ceramic Matrix Composites

    NASA Technical Reports Server (NTRS)

    Kautz, Harold E.

    1996-01-01

    A 13 mJ NdYAG 1064 nm, 4 ns, laser pulse was employed to produce ultrasonic plate waves in 20 percent porous SiC/SiC composite tensile specimens of three different architectures. An air coupled 0.5 MHz transducer was used to detect and collect the waveforms which contained first antisymmetric plate wave pulses for determining the shear wave velocity (VS). These results were compared to VS values determined on the same specimens with 0.5 MHz ultrasonic transducers with contact coupling. Averages of four noncontact determinations on each of 18 specimens were compared to averages of four contact values. The noncontact VS's fall in the same range as the contact. The standard deviations for the noncontact VS's averaged 2.8 percent. The standard deviations for the contact measurements averaged 2.3 percent, indicating similar reproducibility. Repeated laser pulsing at the same location always lead to deterioration of the ulu-"nic signal. The signal would recover in about 24 hr in air however, indicating that no permanent damage was produced.

  8. Rolling contact fatigue in high vacuum using ion plated nickel-copper-silver solid lubrication

    SciTech Connect

    Danyluk, Mike; Dhingra, Anoop

    2011-01-15

    Ion plated, nickel-copper-silver coated steel ball bearings that were tested in rolling contact fatigue (RCF) experiments in high vacuum are presented in this article. ANSI T5 ball bearings were coated with approximately 10 nm of nickel-copper followed by 100 nm of silver using a dc ion plating process. The balls were then tested for RCF in vacuum in the 10{sup -7} Torr range at 130 Hz rotational speed and at 4.1 GPa Hertzian contact stress. The significance of this work is in the extension of RCF testing to an ultrahigh vacuum (UHV) application using silver as a lubricant instead of oil. The effects of pressure and voltage on the ion plating process were also investigated using scanning electron microscopy and RCF life testing in UHV. Test results with a ball size of 5/16 in. in UHV show that deposition at voltages greater than 2.5 kV shortens the RCF life and introduces a unique failure mode. Voltage and pressure fluctuations during the deposition process result in significant thickness monitor measurement errors as well. A regulator control scheme that minimizes the process pressure overshoot is also simulated.

  9. An all-plated, low cost contact system for silicon solar cells

    NASA Technical Reports Server (NTRS)

    Tanner, D. P.; Iles, P. A.; Alexander, P.

    1980-01-01

    The plating sequences Pd-Cr-Cu and Pd-Ni-Cu are demonstrated. The surface was sensitized with a 50 A-thick Pd layer obtained from an immersion bath. After 15 min heating at 400 C in N2, a thin barrier layer of either Cr or Ni was deposited from electroless baths operated at temperatures around 90 C. The sintering process was repeated, and a thin copper layer of 500 A was deposited by electroless means. An electrolytic copper bath was used to build the copper layer to 3-4 micron thicknesses. Cells with good I-V curves were obtained, and the all-plated contacts had good adhesion. Preliminary cost estimates show that the process costs approximately 12 cents per watt excluding the cost of the masking procedure.

  10. Influence of the ARC patterning method and annealing on the contact adhesion of Ni/Cu-plated solar cells

    NASA Astrophysics Data System (ADS)

    Baik, Jong Wook; Lee, Sang Hee; Lee, Doo Won; Lee, Soo Hong

    2016-05-01

    Ni/Cu two-step plating is a promising metallization technique because low contact resistance and improved contact adhesion can be achieved after the Ni annealing process. Also, narrow fingers, which are required for high-efficiency solar cells, can be formed by plating. However, the reliability of contact adhesion is still considered one obstacle to industrializing solar cells with plated metal contacts. In this experiment, the influence of ARC opening methods on plated contact adhesion was investigated because the roughnesses of the Si surfaces produced by using pico-second laser ablation and photolithography may be different. Also, the annealing process was conducted before and after plating Cu/Ag metal stacks. The sequence of the annealing can be significant for efficient production because plating is a wet process while annealing is a dry process. The contact adhesion was measured by using a peel-off test. The test was conducted on a 1.5-mm-wide by a 60 ~ 70- mm-long bus bar area. A 3.2-N/mm adhesion force was recorded as a highest average value along the bus bar.

  11. A new model for thermal contact resistance between fuel cell gas diffusion layers and bipolar plates

    NASA Astrophysics Data System (ADS)

    Sadeghifar, Hamidreza; Djilali, Ned; Bahrami, Majid

    2014-11-01

    A new analytical model is developed to predict the thermal contact resistance (TCR) between fibrous porous media such as gas diffusion layers (GDLs) of polymer electrolyte membrane fuel cells (PEMFCs) and flat surfaces (bipolar plates). This robust model accounts for the salient geometrical parameters of GDLs, mechanical deformation, and thermophysical properties of the contacting bodies. The model is successfully validated against experimental data, and is used to perform in a comprehensive parametric study to investigate the effects of fiber parameters such as waviness and GDL properties on the TCR. Fiber waviness, diameter and surface curvature, as well as GDL porosity, are found to have a strong influence on TCR whereas fiber length does not affect the TCR when the porosity is kept constant. Such findings provide useful guidance for design and manufacturing of more effective GDLs for PEMFC heat management. The analytic model can be readily implemented in simulation and modeling of PEMFCs, and can be extended with minor modifications to other fibrous porous media such as fibrous catalysts, insulating media and sintered metals.

  12. Application of Microbiological Method Direct Epifluorescence Filter Techique/Aerobic Plate Count Agar in the Identification of Irradiated Herbs and Spices

    PubMed Central

    Di Schiavi, Maria Teresa; Foti, Marina; Mosconi, Maria Cristina; Mattiolo, Giuseppina; Cavallina, Roberta

    2014-01-01

    Irradiation is a preservation technology used to improve the safety and hygienic quality of food. Aim of this study was to assess the applicability and validity of the microbiological screening method direct epifluorescence filter technique (DEFT)/aerobic plate count (APC) (EN 13783:2001) for the identification of irradiated herbs and spices. Tests on non-irradiated and irradiated samples of dried herbs and spices were performed. The method was based on the comparison of APC and count obtained using DEFT. In accordance with the standard reference, this method is not applicable to samples with APC<103 colony forming units (CFU)/g and this is its main limit. The results obtained in our laboratories showed that in 50% of cases of non-irradiated samples and in 96% of the samples treated with ionising radiation, the method was not applicable due to a value of CFU/g <103. PMID:27800348

  13. Controlling the hydrophilicity and contact resistance of fuel cell bipolar plate surfaces using layered nanoparticle assembly

    NASA Astrophysics Data System (ADS)

    Wang, Feng

    Hybrid nanostructured coatings exhibiting the combined properties of electrical conductivity and surface hydrophilicity were obtained by using Layer-by-Layer (LBL) assembly of cationic polymer, silica nanospheres, and carbon nanoplatelets. This work demonstrates that by controlling the nanoparticle zeta (zeta) potential through the suspension parameters (pH, organic solvent type and amount, and ionic content) as well as the assembly sequence, the nanostructure and composition of the coatings may be adjusted to optimize the desired properties. Two types of silica nanospheres were evaluated as the hydrophilic component: X-TecRTM 3408 from Nano-X Corporation, with a diameter of about 20 nm, and polishing silica from Electron Microscopy Supply, with diameter of about 65 nm. Graphite nanoplatelets with a thickness of 5~10nm (Aquadag RTM E from Acheson Industries) were used as electrically conductive filler. A cationic copolymer of acrylamide and a quaternary ammonium salt (SuperflocRTM C442 from Cytec Corporation) was used as the binder for the negatively charged nanoparticles. Coatings were applied to gold-coated stainless steel substrates presently used a bipolar plate material for proton exchange membrane (PEM) fuel cells. Coating thickness was found to vary nearly linearly with the number of polymer-nanoparticle layers deposited while a monotonic increase in coating contact resistance was observed for all heterogeneous and pure silica coatings. Thickness increased if the difference in the oppositely charged zeta potentials of the adsorbing components was enhanced through alcohol addition. Interestingly, an opposite effect was observed if the zeta potential difference was increased through pH variation. This previously undocumented difference in adsorption behavior is herein related to changes to the surface chemical heterogeneity of the nanoparticles. Coating contact resistance and surface wettability were found to have a more subtle dependence on the assembly

  14. Effect of sodium dodecylbenzene sulfonate on the motion of three-phase contact lines on the Wilhelmy plate surface.

    PubMed

    Karakashev, Stoyan I; Phan, Chi M; Nguyen, Anh V

    2005-11-15

    The combined approach of the molecular-kinetic and hydrodynamic theories for description of the motion of three-phase gas-liquid-solid contact lines has been examined using the Wilhelmy plate method. The whole dynamic meniscus has been divided into molecular, hydrodynamic, and static-like regions. The Young-Laplace equation and the molecular-kinetic and hydrodynamic dewetting theories have been applied to describe the meniscus profiles and contact angle. The dissipative forces accompanying the dynamic dewetting have also been investigated. The experiments with a Wilhelmy plate made from an acrylic polymer sheet were carried out using a computerized apparatus for contact angle analysis (OCA 20, DataPhysics, Germany). The extrapolated dynamic contact angle versus velocity of the three-phase contact line for Milli-Q water and 5x10(-4) M SDBS solution was experimentally obtained and compared with the combined MHD models with low and moderate Reynolds numbers. The models predict similar results for the extrapolated contact angle. SDBS decreases the equilibrium contact angle and increases the molecular jumping length but does not affect the molecular frequency significantly. The hydrodynamic deformation of the meniscus, viscous dissipation, and friction were also influenced by the SDBS surfactant.

  15. Agar-block microcosms for controlled plant tissue decomposition by aerobic fungi.

    PubMed

    Schilling, Jonathan S; Jacobson, K Brook

    2011-02-03

    The two principal methods for studying fungal biodegradation of lignocellulosic plant tissues were developed for wood preservative testing (soil-block; agar-block). It is well-accepted that soil-block microcosms yield higher decay rates, fewer moisture issues, lower variability among studies, and higher thresholds of preservative toxicity. Soil-block testing is thus the more utilized technique and has been standardized by American Society for Testing and Materials (ASTM) (method D 1413-07). The soil-block design has drawbacks, however, using locally-variable soil sources and in limiting the control of nutrients external (exogenous) to the decaying tissues. These drawbacks have emerged as a problem in applying this method to other, increasingly popular research aims. These modern aims include degrading lignocellulosics for bioenergy research, testing bioremediation of co-metabolized toxics, evaluating oxidative mechanisms, and tracking translocated elements along hyphal networks. Soil-blocks do not lend enough control in these applications. A refined agar-block approach is necessary. Here, we use the brown rot wood-degrading fungus Serpula lacrymans to degrade wood in agar-block microcosms, using deep Petri dishes with low-calcium agar. We test the role of exogenous gypsum on decay in a time-series, to demonstrate the utility and expected variability. Blocks from a single board rip (longitudinal cut) are conditioned, weighed, autoclaved, and introduced aseptically atop plastic mesh. Fungal inoculations are at each block face, with exogenous gypsum added at interfaces. Harvests are aseptic until the final destructive harvest. These microcosms are designed to avoid block contact with agar or Petri dish walls. Condensation is minimized during plate pours and during incubation. Finally, inoculum/gypsum/wood spacing is minimized but without allowing contact. These less technical aspects of agar-block design are also the most common causes of failure and the key source of

  16. Plantar-Plate Disruptions: “The Severe Turf-Toe Injury.” Three Cases in Contact Athletes

    PubMed Central

    Drakos, Mark C.; Fiore, Russell; Murphy, Conor; DiGiovanni, Christopher W.

    2015-01-01

    Objective: To present 3 cases of plantar-plate rupture and turf-toe injury in contact athletes at 1 university and to discuss appropriate diagnosis and treatment algorithms for each case. Background: Turf toe is a common injury in athletes participating in outdoor cutting sports. However, it has been used as an umbrella term to describe many different injuries of the great toe. In some cases, the injury can be so severe that the plantar plate and sesamoid apparatus may be ruptured. These patients may be better managed with surgery than with traditional nonoperative interventions. Differential Diagnosis: Turf toe, plantar-plate disruption, sesamoid fracture. Treatment: For stable injuries in which the plantar plate is not completely disrupted, nonoperative treatment with casting or a stiff-soled shoe, gradual weight bearing, and rehabilitation is the best practice. Unstable injuries require surgical intervention and plantar-plate repair. Uniqueness: Turf toe and injury to the first metatarsophalangeal joint are relatively common injuries in athletes, but few researchers have detailed the operative and nonoperative treatments of plantar-plate disruption in these patients. We examine 3 cases that occurred over 4 seasons on a collegiate football team. Conclusions: Turf toe represents a wide array of pathologic conditions involving the first metatarsophalangeal joint. Stress and instability testing are key components to assess in determining whether surgical intervention is warranted to restore optimal function. Stiffer-soled shoes or shoes with steel-plate insertions may help to prevent these injuries and are useful tools for protection during the rehabilitation period. PMID:25695855

  17. Application of the HHT Method to the Non-contact Thickness Measurement of an Axially Moving Thin Plate

    NASA Astrophysics Data System (ADS)

    Wu, Yangfang; Lu, Qianqian; Xia, Chunlin; Ding, Fan

    2016-06-01

    Non-contact thickness measuring systems can be found in a wide spectrum of technologies. In this paper, Hilbert-Huang transform method is used to analyze the real time signals of a measuring system which includes two round conveyor strings carrying a thin plate, a solar wafer as a sample under test. The vibrations of moving strings and the plate, which are sensitive to moving speed and initial tension in the string, are introduced briefly; the relevant analyses should be helpful for the system design. Using EMD-based time-domain filtering and complementary method, thickness variations and error bands are estimated for different cases. The results show that HHT method as an adaptive time-frequency method, should be potential in measurement engineering applications.

  18. Enhancing the characterization of bedload transport in rivers using the analogy between the Hertz contact theory and plate hydrophone measurements

    NASA Astrophysics Data System (ADS)

    Barrière, Julien; Oth, Adrien; Schenkluhn, Reimar; Krein, Andreas

    2014-05-01

    Vibration measurements performed with plate or pipe geophone/hydrophone systems are of growing interest for bedload transport monitoring since they allow performing high temporal resolution and continuous records. Our set-up is constituted by a piezoelectric hydrophone acting as a "sediment vibration sensor" in contact with a steel plate located on the streambed. With such an apparatus, the signal processing is generally reduced to power spectral analysis or impact counting. However, a large amount of useful information is contained in the waveform of the impact signal, which conveys the force and the contact time that the bedload imposes on the plate. The wave amplitude is not well constrained because it varies a lot with changing impact location and velocity. The wave frequency is a more relevant parameter, less sensitive to these variables. According to the Hertz contact theory the frequency of the first signal arrival (flexural wave) is directly proportional to the bed-material grain size. Then, an appropriate analysis of the frequency attributes (central frequency, modulation) is needed to estimate the size of bedload particles. In this way, we have developed a complete processing algorithm based on a high dimensional decomposition method (chirplet transform) to get an accurate estimation of the first arrival frequency content. Results on summer flood events in a lowland river show that impacts are well separated by their central frequency and that most of transport occurs during larger peak flows. The portion of coarser sediment which is characterized by low frequencies is preferentially transported during the rising limb whereas the finer sand fraction identified by higher frequencies is transported during both rising and falling limb. Such a processing offers the opportunity to better understand the bedload signature of vibration measurements and is promising in view of quantifying processes of bedload transport and deposition. This final objective of

  19. Effect of contact line dynamics on the thermocapillary motion of a droplet on an inclined plate.

    PubMed

    Karapetsas, George; Sahu, Kirti Chandra; Matar, Omar K

    2013-07-16

    We study the two-dimensional dynamics of a droplet on an inclined, nonisothermal solid substrate. We use lubrication theory to obtain a single evolution equation for the interface, which accounts for gravity, capillarity, and thermo-capillarity, brought about by the dependence of the surface tension on temperature. The contact line motion is modeled using a relation that couples the contact line speed to the difference between the dynamic and equilibrium contact angles. The latter are allowed to vary dynamically during the droplet motion through the dependence of the liquid-gas, liquid-solid, and solid-gas surface tensions on the local contact line temperature, thereby altering the local substrate wettability at the two edges of the drop. This is an important feature of our model, which distinguishes it from previous work wherein the contact angle was kept constant. We use finite-elements for the discretization of all spatial derivatives and the implicit Euler method to advance the solution in time. A full parametric study is carried out in order to investigate the interplay between Marangoni stresses, induced by thermo-capillarity, gravity, and contact line dynamics in the presence of local wettability variations. Our results, which are generated for constant substrate temperature gradients, demonstrate that temperature-induced variations of the equilibrium contact angle give rise to complex dynamics. This includes enhanced spreading rates, nonmonotonic dependence of the contact line speed on the applied substrate temperature gradient, as well as "stick-slip" behavior. The mechanisms underlying this dynamics are elucidated herein.

  20. Lamb wave dispersion and anisotropy profiling of composite plates via non-contact air-coupled and laser ultrasound

    NASA Astrophysics Data System (ADS)

    Harb, M. S.; Yuan, F. G.

    2015-03-01

    Conventional ultrasound inspection has been a standard non-destructive testing method for providing an in-service evaluation and noninvasive means of probing the interior of a structure. In particular, measurement of the propagation characteristics of Lamb waves allows inspection of plates that are typical components in aerospace industry. A rapid, complete non-contact hybrid approach for excitation and detection of Lamb waves is presented and applied for non-destructive evaluation of composites. An air-coupled transducer (ACT) excites ultrasonic waves on the surface of a composite plate, generating different propagating Lamb wave modes and a laser Doppler vibrometer (LDV) is used to measure the out-of-plane velocity of the plate. This technology, based on direct waveform imaging, focuses on measuring dispersive curves for A0 mode in a composite laminate and its anisotropy. A two-dimensional fast Fourier transform (2D-FFT) is applied to out-of-plane velocity data captured experimentally using LDV to go from the time-spatial domain to frequency-wavenumber domain. The result is a 2D array of amplitudes at discrete frequencies and wavenumbers for A0 mode in a given propagation direction along the composite. The peak values of the curve are then used to construct frequency wavenumber and phase velocity dispersion curves, which are also obtained directly using Snell's law and the incident angle of the excited ultrasonic waves. A high resolution and strong correlation between numerical and experimental results are observed for dispersive curves with Snell's law method in comparison to 2D-FFT method. Dispersion curves as well as velocity curves for the composite plate along different directions of wave propagation are measured. The visual read-out of the dispersion curves at different propagation directions as well as the phase velocity curves provide profiling and measurements of the composite anisotropy. The results proved a high sensitivity of the air-coupled and laser

  1. Electro-osmosis in gels: Application to Agar-Agar

    NASA Astrophysics Data System (ADS)

    Cherblanc, Fabien; Boscus, Jérôme; Bénet, Jean-Claude

    2008-10-01

    Widely used in food- and bio-engineering as a reference material, Agar-Agar gel is the focus of an experimental investigation concerning the electro-osmosis phenomenon. After presenting the experimental methods, one trial is discussed in detail. A fair reproducibility of results is obtained, and the averaged electro-osmotic permeability is provided. This value lies in the range generally measured on various kind of soils, even if Agar-Agar gel does not share any micro-structural characteristics with soils. To cite this article: F. Cherblanc et al., C. R. Mecanique 336 (2008).

  2. Gravimorphogenesis in agarics.

    PubMed

    Moore, D; Hock, B; Greening, J P; Kern, V D; Novak Frazer, L; Monzer, J

    1996-03-01

    The shape changes which occur in agaric fruit bodies in response to change in the direction of gravity, usually referred to as gravitropism are morphogenetic changes. Our interest in what we prefer to call gravimorphogenesis is to use it to examine morphogenesis experimentally. We are examining two agarics, Coprinus cinereus and Flammulina velutipes, and applying the best available technologies, including video analysis, all forms of electron microscopy, computer-aided image analysis and experiments in orbit in Spacelab. Responses to gravity of the two organisms differ in ways which can be related to their ecological and structural adaptations. C. cinereus reacts extremely rapidly; its fruit body can regain the vertical within 3 h of being placed horizontal, whereas F. velutipes requires 12 h to bend through 90 degrees. The fungi also differ in the bulk of tissue involved in the response. In Coprinus, a zone extending several cm down from the apex is normally involved in bending. In Flammulina, gravisensing is limited to a region just a few mm immediately below the cap, although curvature is performed in a zone of up to 2 cm below. Flammulina cultures were flown on the Spacelab D-2 mission in 1993, and fruit body disorientation in orbit provides the first definitive proof that 'gravitropism' really is a response to the unidirectional gravity vector. Experiments with different clinostat rotation rates in Flammulina indicate that the perception threshold is about 10(-4) x g. Analysis of different times of exposure to an altered gravity vector prior to clinorotation in Coprinus reveals that the perception time is 7 minutes and that continued response requires continued exposure. Cell size determinations in Coprinus demonstrate that cells of the stem increase in length, not diameter, to produce the growth differential. In Flammulina a unique population of highly electron-transparent microvacuoles changes in distribution; decreasing in upper cells and increasing in the

  3. 21 CFR 184.1115 - Agar-agar.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Agar-agar. 184.1115 Section 184.1115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) DIRECT FOOD SUBSTANCES AFFIRMED AS GENERALLY RECOGNIZED AS SAFE Listing of...

  4. Aseptic laboratory techniques: plating methods.

    PubMed

    Sanders, Erin R

    2012-05-11

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: Perform plating procedures without contaminating media. Isolate single bacterial colonies by the streak-plating

  5. Aseptic Laboratory Techniques: Plating Methods

    PubMed Central

    Sanders, Erin R.

    2012-01-01

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: ● Perform plating procedures without contaminating media. ● Isolate single bacterial colonies by the

  6. Drops down the hill: theoretical study of limiting contact angles and the hysteresis range on a tilted plate.

    PubMed

    Krasovitski, Boris; Marmur, Abraham

    2005-04-26

    The limiting inclination angle (slip angle), for which a two-dimensional water drop may be at equilibrium on a chemically heterogeneous surface, is exactly calculated for a variety of cases. The main conclusion is that, in the cases studied, the contact angles at the upper and lower contact line do not always simultaneously equal the receding and advancing contact angles, respectively. On a hydrophobic surface, the lowest contact angle (at the upper contact line) tends to be approximately equal to the receding contact angle, while the highest contact angle (at the lower contact line) may be much lower than the advancing contact angle. For hydrophilic surfaces, the opposite is true. These conclusions imply that the hysteresis range cannot in general be measured by analyzing the shape of a drop on an inclined plane. Also, the limiting inclination angle cannot in general be calculated from the classical equation based only on the advancing and receding contact angles.

  7. A Hidden Pitfall in the Preparation of Agar Media Undermines Microorganism Cultivability

    PubMed Central

    Tanaka, Tomohiro; Kawasaki, Kosei; Daimon, Serina; Kitagawa, Wataru; Yamamoto, Kyosuke; Tamaki, Hideyuki; Tanaka, Michiko; Nakatsu, Cindy H.

    2014-01-01

    Microbiologists have been using agar growth medium for over 120 years. It revolutionized microbiology in the 1890s when microbiologists were seeking effective methods to isolate microorganisms, which led to the successful cultivation of microorganisms as single clones. But there has been a disparity between total cell counts and cultivable cell counts on plates, often referred to as the “great plate count anomaly,” that has long been a phenomenon that still remains unsolved. Here, we report that a common practice microbiologists have employed to prepare agar medium has a hidden pitfall: when phosphate was autoclaved together with agar to prepare solid growth media (PT medium), total colony counts were remarkably lower than those grown on agar plates in which phosphate and agar were separately autoclaved and mixed right before solidification (PS medium). We used a pure culture of Gemmatimonas aurantiaca T-27T and three representative sources of environmental samples, soil, sediment, and water, as inocula and compared colony counts between PT and PS agar plates. There were higher numbers of CFU on PS medium than on PT medium using G. aurantiaca or any of the environmental samples. Chemical analysis of PT agar plates suggested that hydrogen peroxide was contributing to growth inhibition. Comparison of 454 pyrosequences of the environmental samples to the isolates revealed that taxa grown on PS medium were more reflective of the original community structure than those grown on PT medium. Moreover, more hitherto-uncultivated microbes grew on PS than on PT medium. PMID:25281372

  8. Influence of process parameters on rolling-contact-fatigue life of ion plated nickel-copper-silver lubrication

    SciTech Connect

    Danyluk, Mike; Dhingra, Anoop

    2012-05-15

    In this paper, we present a connection between argon ion flux, element-mixing, and rolling contact fatigue (RCF) life of a thin film nickel-copper-silver lubricant on ball bearings. The film is deposited on the balls using an ion plating process and tested for RCF in high vacuum. The ion flux is measured using a Langmuir probe and the plane stress within the film during deposition is calculated using a thin film model. Experiments reveal that there is an inverse relationship between ion flux and RCF life for most deposition voltage and pressure combinations tested, specifically, 15.5-18.5 mTorr and 1.5-3.5 kV. For voltages up to 2.5 kV, RCF life decreases as ion flux increases due to increased compressive stress within the film, reaching as high as 2.6 GPa. For voltages between 2.5 and 3.5 kV, interlayer mixing of nickel and copper with the silver layer reduces RCF life due to contamination, even as ion flux and corresponding film compressive stress are reduced. A Monte Carlo-based simulation tool, SRIM is used to track collision cascades of the argon ions and metal atoms within the coating layers. At process voltages above 2.5 kV we observe elemental mixing of copper and nickel with the silver layer using Auger electron spectroscopy of coated steel and Si{sub 3}N{sub 4} balls. The authors conclude that an ion flux greater than 5.0 x 10{sup 14} cm{sup -2} s{sup -1} leads to reduced RCF life due to high film stress. In addition, process voltages greater than 2.5 kV also reduce RCF life due to contamination and interlayer mixing of nickel and copper within the silver layer.

  9. Efficacy of reducing agent and surfactant contacting pattern on the performance characteristics of nickel electroless plating baths coupled with and without ultrasound.

    PubMed

    Agarwal, Amrita; Pujari, Murali; Uppaluri, Ramgopal; Verma, Anil

    2014-07-01

    This article addresses furthering the role of sonication for the optimal fabrication of nickel ceramic composite membranes using electroless plating. Deliberating upon process modifications for surfactant induced electroless plating (SIEP) and combined surfactant and sonication induced electroless plating (SSOEP), this article highlights a novel method of contacting of the reducing agent and surfactant to the conventional electroless nickel plating baths. Rigorous experimental investigations indicated that the combination of ultrasound (in degas mode), surfactant and reducing agent pattern had a profound influence in altering the combinatorial plating characteristics. For comparison purpose, purely surfactant induced nickel ELP baths have also been investigated. These novel insights consolidate newer research horizons for the role of ultrasound to achieve dense metal ceramic composite membranes in a shorter span of total plating time. Surface and physical characterizations were carried out using BET, FTIR, XRD, FESEM and nitrogen permeation experiments. It has been analyzed that the SSOEP baths provided maximum ratio of percent pore densification per unit metal film thickness (PPDδ) and hold the key for further fine tuning of the associated degrees of freedom. On the other hand SIEP baths provided lower (PPDδ) ratio but higher PPD. For SSOEP baths with dropwise reducing agent and bulk surfactant, the PPD and metal film thickness values were 73.4% and 8.4 μm which varied to 66.9% and 13.3 μm for dropwise reducing agent and drop surfactant case.

  10. Residual Agar Determination in Bacterial Spores by Electrospray Ionization Mass Spectrometry

    SciTech Connect

    Wahl, Karen L.; Colburn, Heather A.; Wunschel, David S.; Petersen, Catherine E.; Jarman, Kristin H.; Valentine, Nancy B.

    2010-02-15

    Presented here is an analytical method to detect residual agar from a bacterial spore sample as an indication of culturing on an agar plate. This method is based on the resolubilization of agar polysaccharide from a bacterial spore sample, enzymatic digestion, followed by electrospray ionization tandem mass spectrometry (ESI-MSn) analysis for detection of a specific agar fragment ion. A range of Bacillus species and strains were selected to demonstrate the effectiveness of this approach. The characteristic agar fragment ion was detected in the spores grown on agar that were washed from 1 to 5 times, irradiated or non-irradiated and not in the spores grown in broth. A sample containing approximately 108 spores is currently needed for confident detection of residual agar from culture on agar plates in the presence of bacterial spores with a limit of detection of approximately 1 ppm agar spiked into a broth-grown spore sample. The results of a proficiency test with 42 blinded samples are presented demonstrating the utility of this method with no false positives and only 3 false negatives for samples that were below the detection level of the method as documented.

  11. Method for Measuring Changes in Surface Tension on Agar

    PubMed Central

    Weisberg, David S.; Dworkin, Martin

    1983-01-01

    The surface tension of agar surfaces was determined by measuring the contact angles formed by drops of various hydrophobic liquids on the surface and then calculating the composite surface free energy function by solving a series of simultaneous equations derived from these data. This method was used to measure the change in the surface tension of agar produced by the addition of various concentrations of albumin. The resulting curve was typical of the effect of increasing concentrations of surfactants on surface tension. The method was compared with other methods of determining surface tension of solids, and it was concluded that the technique used here provided the most reliable results. PMID:16346273

  12. A novel agar formulation for isolation and direct enumeration of Vibrio vulnificus from oyster tissue.

    PubMed

    Griffitt, Kimberly J; Grimes, D Jay

    2013-08-01

    A new selective and differential medium, Vibrio vulnificus X-Gal (VVX), was developed for direct enumeration of V. vulnificus (Vv) from oyster samples. This agar utilizes cellobiose and lactose as carbon sources, and the antibiotics colistin and polymyxin B as selective agents. Hydrolysis of 5-bromo-4-chloro-3-indolyl- beta-d-galactopyranoside (x-gal), used in the agar as a lactose analog, produces an insoluble blue dye that makes lactose positive colonies easily distinguishable from any non-lactose fermenting bacteria. Various bacterial species were spot plated onto thiosulfate-citrate-bile salts-sucrose agar (TCBS), and CHROMagar Vibrio, two vibrio-specific selective agars, non-selective agar, and VVX to compare selectivity of VVX to other widely used media. A V. vulnificus pure culture was serially diluted on VVX and non-selective agar to determine the VVX percent recovery. Water and oyster samples were spread plated on VVX agar and allowed to incubate for 16-18 h at 33 °C. Blue and white colonies from VVX agar were picked and screened by end point PCR for the Vv hemolysin vvhA. VVX agar showed a significant improvement over TCBS and CHROMagar at preventing non-target growth. There was an 87.5% recovery compared to non-selective plating and a 98% positivity rate of blue colonies picked from oyster tissue plating. The findings suggest that this new agar is a fast, distinctive, and accurate method for enumeration of V. vulnificus from the environment.

  13. [Evaluation of a new medium, eggplant (Solanum melongena) agar as a screening medium for Cryptococcus neoformans in environmental samples].

    PubMed

    Sengul, Mustafa; Ergin, Cağrı; Kartal, Tuğba

    2014-04-01

    .neoformans colony forming unit (cfu) per plate were found as 51, 57 and 48 (median values) on simplified Staib agar, Pal's agar and eggplant agar, respectively, while tobacco agar has lower performance with 33 cfu/petri. No statistically significant difference were found between simplified Staib agar, Pal's agar and eggplant agar's performances for C.neoformans isolations from the nature (p=0.71). In conclusion, easily prepared eggplant agar is as functional as widely used media such as simplified Staib agar and Pal's agar for the isolation of C.neoformans from the natural environment.

  14. Influence of the contact line velocity on the finger formation of the liquid film expanding on an inclined plate

    NASA Astrophysics Data System (ADS)

    Yamashita, Masatoshi; Nishikawa, Masato; Ito, Takahiro; Tsuji, Yoshiyuki

    2015-11-01

    When a liquid film flows down on an inclined solid surface, the contact line can be destabilized to finger shape. This phenomenon leads to the non-uniform height of the liquid surface or even to generation of dry patch, and then has a great effect on cooling of energy device and quality of coating. In previous studies, the final finger shapes have been discussed by relating the with capillary (Ca) number and the wetting properties of the liquid for the solid substrate, i.e. the contact angle. However, in the experimental studies, little attention has been paid on the difference between the static contact angle and the dynamic one, the latter which is actually observed when the finger is developing. In this study, we performed three-dimensional measurement of surface geometry of the liquid film to clarify how the dynamic contact angles and the Ca number influence the finger shape by optical method. We observed two different finger shapes depending on the volumes of the working fluid., and verified that the finger shapes depend on the contact angle scaled by Ca number. We found that the local dynamic contact angle and the contact line velocity on the trough part of the wavy contact line can be highly related with the final finger shape.

  15. [The plate in the zone of oocyte and germinal epithelium contact in scyphomedusa Aurelia aurita binds antibodies to ZP-domain-containing protein mesoglein].

    PubMed

    Adonin, L S; Podgornaia, O I; Matveev, I V; Shaposhnikova, T G

    2009-01-01

    Cnidaria are lower multicellular animals with the body consisting of two epithelial layers. An extracellular substance--mesoglea--is situated between epidermal and gastrodermal layers of these animals. Mesoglein is one of the major mesogleal proteins of adult medusa of Scyphozoan jellyfish Aurelia aurita. Search for the known domains in mesoglein amino acid sequence reveals prominent zona pellucida (ZP) domain (which was found at first in the mammal oocyte zona pellucida proteins), so the protein belongs to ZP family of extracellular matrix proteins and it is an early metazoan member of ZP-domain-containing protein family. However, nothing is known about oogenesis related ZP-domain proteins in the lower multicellular animals. Oogenesis in Scyphozoa is described poorly. In this work morphological features of the zone in contact area between the oocyte and the germinal epithelium were investigated in semi-fine sections: To make it more convenient we identified seven stages according to the oocyte size and the structure found in this area was named the plate. It was shown that the components of the plate bound specifically the antibodies against mesoglein. So it seems the plate material contains ZP-domain proteins. Electrophoresis and immunoblot results give evidence that the proteins immunologically related to mesoglein have a higher molecular mass. It might be due to either the posttranslational modifications of the precursors or that they represent other proteins of ZP-domain family in Cnidaria.

  16. Influence of surface roughness on the tribo-electric process for a sliding contact between polymeric plate materials

    NASA Astrophysics Data System (ADS)

    Neagoe, M. B.; Prawatya, Y. E.; Zeghloul, T.; Dascalescu, L.

    2017-02-01

    Polymers are used in many industrial applications due to their good mechanical and thermal properties. Studies have shown that electrical insulators, such as the polymers, are generating electrostatic charge by frictional contact. This tribo-charging effect influences de sliding conditions, and the level of charge depends of several factors. The aim of this paper is to validate two paradigms: (I) the electrostatic charge increases with contact pressure; (II) the level of charge is influenced by the number of contact points on the surface. The tribocharging experiments were carried out with samples cut from two polymers: Acrylonitrile-Butadiene-Styrene, 5 mm x 15mm x100 mm, roughness: Ra = 0.4 µm and Polyvinyl Chloride, 5 mm x 50 mm x 180 mm, with various roughness values: Ra = 3-12 µm and RSm = 150-350 µm. The modification of asperity density was accompanied by changes in the electric potential measured at the surface of the PVC samples. Thus, its average value V increased from -0.33 to -0.85 kV, and its maximum value Vmax, from -1.56 to -4.83 kV.

  17. The physicochemical property characterization of agar acetate.

    PubMed

    Xia, Kai; Liu, Xin; Zhao, Jingkun; Zhang, Xiaodong

    2014-09-22

    A series of agar acetates with different degree of substitution (DS) were prepared, and their properties were determined and analyzed. The results showed that the gelling temperature, the gel melting temperature, the gel strength, the gel hardness, the gel fracturability, the gel springiness and the solution apparent viscosity of agar acetates all decreased except that their gel cohesiveness increased with the increase of DS. The variation process of agar molecules in solution from coil to helix could be also observed by measuring solution optical rotation in a lower concentration at which even the solution could not form a gel. The gel skeleton structures of agar acetates were of porous network structures, and the pores became smaller and denser with the increase of DS. After acetylation, the water holding capacity of the agar was improved, but its thermal stability was lowered.

  18. NAS agar is more suitable than McKay agar for primary culture of Streptococcus milleri group (SMG) fastidious bacteria, S. intermedius in particular.

    PubMed

    Raclavsky, Vladislav; Novotny, Radko; Stary, Lubomir; Navratilova, Lucie; Zatloukal, Jaromir; Jakubec, Petr; Zapalka, Martin; Kopriva, Frantisek; Kolek, Vitezslav

    2017-01-01

    Streptococcus milleri group (SMG) is a group of three streptococcal species (S. anginosus, intermedius and constellatus) that act as opportunist pathogens, among others in cystic fibrosis. Due to their fastidious character, they are both difficult to cultivate and to differentiate from less pathogenic streptococcal species, therefore being most probably underdiagnosed. Semi-selective McKay agar and NAS agar were developed to facilitate SMG recovery from clinical samples; however, direct comparison of recovery rates has not been published yet. We tested the performance of both media on 123 patient samples and demonstrated general superiority of NAS agar for SMG recovery during primary cultivation convincingly. This observation was also confirmed by quantitative drop tests during subculture. Despite the undisputed overall superiority of NAS agar over McKay agar, a smaller fraction of strains grew better on McKay agar. Inter-strain differences were the most probable explanation. Therefore, when economic conditions are not limiting and maximum recovery rate is desirable, both plates are advised to be used in parallel for primary cultivation of clinical samples.

  19. Xanthan gum: an economical partial substitute for agar in microbial culture media.

    PubMed

    Babbar, Shashi B; Jain, Ruchi

    2006-04-01

    Xanthan gum, microbial desiccation-resistant polysaccharide prepared commercially by aerobic submerged fermentation from Xanthomonas campestris, has been successfully used alone and in combination with agar for microbial culture media. As illustrative examples, eight bacteria and eight fungi were grown on media solidified with either agar (A, 1.5%), xanthan gum (X, 1%), or combinations of both (0.9% X + 0.1% A, 0.8% X + 0.2% A, 0.7% X + 0.3% A, 0.6% X + 0.4% A). All fungi and bacteria exhibited normal growth and differentiation in all these treatments. Rather, growth of most of the fungi was better on xanthan (alone) and xanthan + agar media than agar medium. As the media gelled with xanthan gum alone flow, it was not possible to incubate Petri plates in inverted position. Moreover, because of the softness, streaking of bacteria was difficult on such media. However, these problems could be overcome by partially replacing xanthan gum with 0.3% agar. Bacterial enumeration studies carried out for Serratia sp. and Pseudomonas sp. by serial dilution and pour-plate method on agar (1.5%), 0.7%/0.6% X + 0.3%/0.4% A yielded similar counts. Selective media, succinate medium for Pseudomonas sp., and MacConkey broth medium for Escherichia coli gelled with 0.7%/0.6% X + 0.3%/0.4% A did not support growth of other bacteria when inoculated along with the above-mentioned bacteria. Likewise, differential medium, CRMA (Congo red mannitol agar) gelled with xanthan-agar combination could differentiate between Agrobacterium tumefaciens and Rhizobium sp.

  20. Some Experiments With Agar-Grown Seedlings

    ERIC Educational Resources Information Center

    Freeland, P. W.

    1973-01-01

    Two percent agar gel is reported as a better medium for germination and growth studies. Students can be encouraged to undertake many simple experiments and make precise observations by using this medium. (PS)

  1. Numerical modelling of seismic wave propagation along the plate contact of the Hellenic Subduction Zone-the influence of a deep subduction channel

    NASA Astrophysics Data System (ADS)

    Essen, Katja; Braatz, Mandy; Ceranna, Lars; Friederich, Wolfgang; Meier, Thomas

    2009-12-01

    We model seismic wave propagation from intermediate depth earthquakes in a subduction zone using a 2-D Chebyshev pseudospectral method. Particular attention is directed to the influence of a deep, low-viscosity subduction channel on top of the plate contact where metamorphic rocks may be exhumed by forced return flow. The study is motivated by observations of complicated dispersive and high-amplitude P- and S-wave trains in the forearc of the Hellenic Subduction Zone. The basic model is a subducted slab with a thin oceanic crust forming a low-velocity layer. Our model setup closely follows recent results on the structure of the Hellenic Subduction Zone obtained from receiver functions and surface wave studies. They exhibit an abrupt change of the dip of the downgoing slab at about 70 km depth. The subduction channel is modelled as a thin, wedge-shaped layer of intermediate seismic velocity above a slower oceanic crust and below a faster overlying mantle wedge. We also look into the effects of a continuous phase transition from basalt to eclogite in the subducted oceanic crust and near-surface crustal structures. In all models, wave propagation is characterized by dispersive guided channel waves trapped in the low-velocity subducted crust. They produce high-amplitude arrivals in the forearc. A fast guided wave train (gP) originates from the direct P wave and a slower one (gS) from the direct S wave. Guided waves are radiated into the overlying mantle where the dip of the slab is abruptly changing. Seismogram sections for models without a subduction channel typically show two spatially separated guided wave trains, one following the oceanic crust and one travelling more steeply towards the forearc high. A subduction channel above the plate contact enhances the radiation effect of gP waves at the slab bend due to the weaker velocity contrast and inhibits the separation of the wave trains. In models with additional near-surface crustal structures the wave field is

  2. Morphological development of Morchella conica mycelium on different agar media.

    PubMed

    Guler, P; Ozkaya, E G

    2009-07-01

    The present study presents the development of mycelium of Morchella conica where different concentration of sucrose added at different agar media. For this sucrose have been added as 0.25, 0.50, 0.75, 1.00 and 1.25% concentration to wheat agar potato dextrose agar malt extract agar and complete medium yeast agar The radial growth speed, morphologic specifications, radial growth radius and pigmentation of mycelium were taken as criteria, the development period of mycelium in wheat agar was completed in 4 days and mycelium were very thin. The colonization period of the mycelium was determined; 7 days in potato dextrose agar 5 days in malt extract agar and 5 days at complete medium yeast agar. The development of the mycelium; at potato dextrose agar was dense and circular; at malt extract agar and at completed medium yeast agar was rhizomorphic. Mycelium has developed very well at sucrose medium and formed creamy and light yellow pigmentation.

  3. The Effect of Stress and TiC Coated Balls on Lubricant Lifetimes Using a Vacuum Ball-on-Plate Rolling Contact Tribometer

    NASA Technical Reports Server (NTRS)

    Jones, William R., Jr.; Jansen, Mark J.; Helmick, Larry H.; Nguyen, QuynhGiao; Wheeler, Donald R.; Voving, Hans J.

    1999-01-01

    A vacuum ball-on-plate rolling contact tribometer was used to determine the relative lifetimes of a perfluoropolyether (Krytox 143 AC) on 440C stainless steel. The effect of mean Hertzian stresses (0.75, 1.0, 1.5 and 2.0 GPa) and the use of TiC coated balls on lubricant lifetime was studied. Other conditions included: approximately 100 rpm, approximately 50 micrograms of lubricant, an initial vacuum level of less than 1.0 x 1O(exp -8) Torr, and room temperature (approximately 23 C). increasing the mean Hertzian stress from 0.75 to 2.0 GPa results in an exponential decrease in lubricant lifetime for both material combinations. However. substituting a TiC ball for the 440C ball quadrupled lifetime at low stress levels (0.75 and 1.0 GPa) and doubled life at higher stresses (1.5 and 2.0 GPa). The reduced reactivity of the TiC surface with the PFPE lubricant is considered to be the reason for this enhancement. Decreasing lifetime with increasing stress levels correlated well with energy dissipation calculations.

  4. The Effect of Stress and TiC Coated Balls on Lubricant Lifetimes Using a Vacuum Ball-on-Plate Rolling Contact Tribometer

    NASA Technical Reports Server (NTRS)

    Jones, William R., Jr.; Jansen, Mark J.; Helmick, Larry H.; Nguyen, QuynhGiao; Wheeler, Donald R.; Boving, Hans J.

    1999-01-01

    A vacuum ball-on-plate rolling contact tribometer was used to determine the relative lifetimes of a perfluoropolyether (Krytox 143 AC) on 440C stainless steel. The effect of mean Hertzian stresses (0.75, 1.0, 1.5, and 2.0 GPa) and the use of TiC-coated balls on lubricant lifetime was studied. Other conditions included: 100 rpm, 50 micro-g of lubricant, an initial vacuum level of less than 1.0 x 10(exp -8) Torr, and room temperature (23 C). Increasing the mean Hertzian stress from 0.75 to 2.0 GPa results in an exponential decrease in lubricant lifetime for both material combinations. However, substituting a TiC ball for the 440C ball quadrupled lifetime at low stress levels (0.75 and 1.0 GPa) and doubled life at higher stresses (1.5 and 2.0 GPa). The reduced reactivity of the TiC surface with the PFPE lubricant is considered to be the reason for this enhancement. Decreasing lifetime with increasing stress levels correlated well with energy dissipation calculations.

  5. Use of agar diffusion assay to evaluate bactericidal activity of formulations of alkaline salts of fatty acids against bacteria associated with poultry processing

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The agar diffusion assay was used to examine antibacterial activity of alkaline salts of fatty acids (FA). Wells in agar media seeded with bacteria were filled with FA-potassium hydroxide (KOH) solutions, plates were incubated, and zones of inhibition were measured. The relationship between bacteric...

  6. Pigments of fly agaric (Amanita muscaria).

    PubMed

    Stintzing, Florian; Schliemann, Willibald

    2007-01-01

    The complex pigment pattern of fly agaric (Amanita muscaria) cap skins has been studied by LC-DAD and mass spectrometry. Among the betaxanthins the corresponding derivatives of serine, threonine, ethanolamine, alanine, Dopa, phenylalanine and tryptophan are reported for the first time to contribute to the pigment pattern of fly agarics. Betalamic acid, the chromophoric precursor of betaxanthins and betacyanins, muscaflavin and seco-dopas were also detected. Furthermore, the red-purple muscapurpurin and the red muscarubrin were tentatively assigned while further six betacyanin-like components could not be structurally allocated. Stability studies indicated a high susceptibility of pigment extracts to degradation which led to rapid colour loss thus rendering a complete characterization of betacyanin-like compounds impossible at present. Taking into account these difficulties the presented results may be a starting point for a comprehensive characterization of the pigment composition of fly agarics.

  7. Comparison of seven plating media for enumeration of Listeria spp.

    PubMed Central

    Loessner, M J; Bell, R H; Jay, J M; Shelef, L A

    1988-01-01

    The suitability of seven media for the enumeration of Listeria spp. was evaluated at 30 degrees C for 48 h. The media tested were (i) the original McBride Listeria agar formulation (with glycine); (ii) modified McBride agar containing glycine anhydride; (iii) LiCl-phenylethanol-moxalactam (LPM) agar; (iv) acriflavine-ceftazidime agar; (v) Rodriguez isolation agar (RISA); (vi) modified Vogel-Johnson (MVJ) agar; (vii) cyclohexanedione-nalidixic acid-phenylethanol agar; and tryptose agar as control. A total of 66 organisms were used including 11 Listeria monocytogenes strains and 5 other Listeria spp. For L. monocytogenes strains only, all media performed highly similarly. Of the other Listeria spp., only two grew on MVJ agar and three each grew on LPM and RISA. Only LPM agar inhibited the 50 non-listeriae, including five yeasts, while MVJ agar inhibited all but one yeast. The McBride Listeria agar formulation that contained glycine anhydride was less selective than the original. When pure cultures of 10 bacteria (including one L. monocytogenes strain) were combined and plated on four media, L. monocytogenes colonies were easiest to enumerate on MVJ agar, followed by LPM and RISA. These media ranked in the same order when plated with homogenates of various foods to which was added L. monocytogenes Scott A, but LPM agar was the best overall since Scott A was inhibited by MVJ. Upon microscopic examination of listerial colonies from the plating media, atypical cell morphology was noted with cells being about twofold in size on LPM, MVJ, and acriflavine-ceftazidime agars. Overall, LPM agar was the most suitable of the media tested even though it was inhibitory to Listeria grayi and Listeria murrayi. PMID:3146947

  8. Standard operating procedure to prepare agar phantoms

    NASA Astrophysics Data System (ADS)

    Souza, R. M.; Santos, T. Q.; Oliveira, D. P.; Souza, R. M.; Alvarenga, A. V.; Costa-Felix, R. P. B.

    2016-07-01

    Agar phantoms are widely used as soft tissue mimics and some preparation techniques are described in the literature. There are also standards that describe the recipe of a soft tissue mimicking material (TMM). However some details of manufacture process are not clearly defined. The standardization of the phantom's preparation can produce a metrological impact on the results of the acoustic properties measured. In this direction, this paper presents a standard operating procedure (SOP) to prepare the agar TMM described on the IEC 60601-237.

  9. The Efficiency of UVC Radiation in the Inactivation of
Listeria monocytogenes on Beef-Agar Food Models

    PubMed Central

    James, Christian; James, Stephen

    2015-01-01

    Summary The aim of this study is to evaluate the effect of meat content and surface smoothness on the deactivation of Listeria monocytogenes in beef-agar food models achieved by shortwave ultraviolet (UVC) light. Food models with various meat contents were made using chopped beef slices and agar solution. Prepared models together with a Listeria selective agar (LSA) plate and a slice of cooked beef were inoculated with L. monocytogenes and then exposed to UVC light. Population of Listeria reduced to below the level of detection on the LSA plates. As the content of beef in the beef-agar models increased, more L. monocytogenes cells survived. Survival was greatest on the treated cooked slice of beef. To better understand the effect of surface irregularities, a white light interferometer was used to analyse the surface smoothness of beef-agar media and LSA plates. No correlation was observed between the surface roughness of seven out of nine types of produced beef-agar media and the degree of inactivation resulting from UVC radiation at the given dose, whereas, less bacterial cells were killed as beef content of the food models increased. The findings of the current study show that the chemical composition of the treated sample also plays an important role in pathogen resistance and survival, meaning that two samples with similar surface irregularities but different chemical composition might produce very different inactivation results when exposed to UVC light. PMID:27904353

  10. Evaluation of the antibacterial effects of vancomycin hydrochloride released from agar-gelatin-bioactive glass composites.

    PubMed

    Rivadeneira, Josefina; Di Virgilio, Ana Laura; Audisio, M Carina; Boccaccini, Aldo R; Gorustovich, Alejandro A

    2015-01-13

    The aim of this work was to evaluate the perfomance of agar-gelatin (AG) composites and AG-containing 45S5 bioactive glass (BG) microparticles (AGBG) in relation to their water uptake capacity, sustained release of a drug over time, and antibacterial effects. The composites were fabricated by the gel-casting method. To impart the local drug release capacity, vancomycin hydrochloride (VC) was loaded in the composites in concentrations of 0.5 and 1 mg ml(-1). VC release was assessed in distilled water at 37 °C up to 72 h and quantified spectrophotometrically. The antibacterial activity of composites was evaluated by the inhibition zone test and the plate count method. The experiments were performed in vitro up to 48 h on three staphylococcus strains: Staphylococcus aureus ATCC29213, S. aureus ATCC6538 and Staphylococcus epidermidis ATCC12228. The results showed that the addition of BG to AG composites did not affect the degree of water uptake. The release of VC was significantly affected by the presence of BG. VC release was higher from AGBGVC films than from AGVC ones over prolonged incubation times. Bacterial inhibition zones were found around the composites. The halos were larger when the cells were put in contact with AGVC composites than when they were put in contact with AGBGVC ones. Nevertheless, the viable count method demonstrated that the composites inhibited Staphylococcus cell growth with no statistical differences. In conclusion, the addition of BG did not reflect an improvement in the parameters studied. On the other hand, composites loaded with VC would have a role in prophylaxis against bacterial infection.

  11. Use of agar agar stabilized milled zero-valent iron particles for in situ groundwater remediation

    NASA Astrophysics Data System (ADS)

    Schmid, Doris; Velimirović, Milica; Wagner, Stephan; Micić Batka, Vesna; von der Kammer, Frank; Hofmann, Thilo

    2015-04-01

    A major obstacle for use of nanoscale zero-valent iron (nZVI) particles as a nontoxic material for effective in situ degradation of chlorinated aliphatic hydrocarbons (CAHs) is the high production cost. For that reason, submicro-scale milled zero-valent iron particles were recently developed (milled ZVI, UVR-FIA, Germany) by grinding macroscopic raw materials of elementary iron as a cheaper alternative to products produced by solid-state reduction. However, milled ZVI particles tend to aggregate and due to the rather large particle size (d50= 11.9 µm) also rapidly sediment. To prevent aggregation and consequently sedimentation of milled ZVI particles and therefore improve the mobility after in situ application, the use of a stabilizer is considered in literature as a most promising option. In this study, milled ZVI particles (1 g L-1 of particle concentration) were stabilized by environmentally friendly polymer agar agar (>0.5 g L-1), which had a positive impact on the milled ZVI stability. Sedimentation rate was significantly decreased by increasing the suspension viscosity. Column transport experiments were performed for bare and agar agar stabilized milled ZVI particles in commercially available fine grained quartz sand (DORSILIT® Nr.8, Gebrüder Dorfner GmbH Co, Germany) and different porous media collected from brownfields. The experiments were carried out under field relevant injection conditions of 100 m d-1. The maximal travel distance (LT) of less than 10 cm was determined for non-stabilized suspension in fine grained quartz sand, while agar agar (1 g L-1) stabilized milled ZVI suspension revealed LT of 12 m. Similar results were observed for porous media from brownfields showing that mobility of agar agar stabilized particle suspensions was significantly improved compared to bare particles. Based on the mobility data, agar agar stabilized milled zero-valent iron particles could be used for in situ application. Finally, lab-scale batch degradation

  12. Normal force controlled rheology applied to agar gelation

    NASA Astrophysics Data System (ADS)

    Mao, Bosi; Divoux, Thibaut; Snabre, Patrick

    2016-05-01

    A wide range of thermoreversible gels are prepared by cooling down to ambient temperature hot aqueous polymer solutions. During the sol-gel transition, such materials may experience a volume contraction which is traditionally overlooked as rheological measurements are usually performed in geometries of constant volume. In this article, we revisit the formation of 1.5\\% wt. agar gels through a series of benchmark rheological experiments performed with a plate-plate geometry. We demonstrate on that particular gel of polysaccharides that the contraction associated with the sol/gel transition cannot be neglected. Indeed, imposing a constant gap width during the gelation results in the strain hardening of the sample, as evidenced by the large negative normal force that develops. Such hardening leads to the slow drift in time of the gel elastic modulus $G'$ towards ever larger values, and thus to an erroneous estimate of $G'$. As an alternative, we show that imposing a constant normal force equals to zero during the gelation, instead of a constant gap width, suppresses the hardening as the decrease of the gap compensates for the sample contraction. Using normal force controlled rheology, we then investigate the impact of thermal history on 1.5\\% wt. agar gels. We show that neither the value of the cooling rate, nor the introduction of a constant temperature stage during the cooling process influence the gel elastic properties. Instead, $G'$ only depends on the terminal temperature reached at the end of the cooling ramp, as confirmed by direct imaging of the gel microstructure by cryoelectron microscopy. The present work offers an extensive review of the technical difficulties associated with the rheology of hydrogels and paves the way for a systematic use of normal force controlled rheology to monitor non-isochoric processes.

  13. Comparison of Fecal Coliform Agar and Violet Red Bile Lactose Agar for Fecal Coliform Enumeration in Foods

    PubMed Central

    Leclercq, A.; Wanegue, C.; Baylac, P.

    2002-01-01

    A 24-h direct plating method for fecal coliform enumeration with a resuscitation step (preincubation for 2 h at 37 ± 1°C and transfer to 44 ± 1°C for 22 h) using fecal coliform agar (FCA) was compared with the 24-h standardized violet red bile lactose agar (VRBL) method. FCA and VRBL have equivalent specificities and sensitivities, except for lactose-positive non-fecal coliforms such as Hafnia alvei, which could form typical colonies on FCA and VRBL. Recovery of cold-stressed Escherichia coli in mashed potatoes on FCA was about 1 log unit lower than that with VRBL. When the FCA method was compared with standard VRBL for enumeration of fecal coliforms, based on counting carried out on 170 different food samples, results were not significantly different (P > 0.05). Based on 203 typical identified colonies selected as found on VRBL and FCA, the latter medium appears to allow the enumeration of more true fecal coliforms and has higher performance in certain ways (specificity, sensitivity, and negative and positive predictive values) than VRBL. Most colonies clearly identified on both media were E. coli and H. alvei, a non-fecal coliform. Therefore, the replacement of fecal coliform enumeration by E. coli enumeration to estimate food sanitary quality should be recommended. PMID:11916678

  14. Improved soft-agar colony assay in a fluid processing apparatus.

    PubMed

    Forsman, A D; Herpich, A R; Chapes, S K

    1999-01-01

    The standard method for quantitating bone marrow precursor cells has been to count the number of colony-forming units that form in semisolid (0.3%) agar. Recently we adapted this assay for use in hardware, the Fluid Processing Apparatus, that is flown in standard payload lockers of the space shuttle. When mouse or rat macrophage colony-forming units were measured with this hardware in ground-based assays, we found significantly more colony growth than that seen in standard plate assays. The improved growth correlates with increased agar thickness but also appears to be due to properties inherent to the Fluid Processing Apparatus. This paper describes an improved method for determining bone marrow macrophage precursor numbers in semisolid agar.

  15. Performance of CHROMAGAR candida and BIGGY agar for identification of yeast species

    PubMed Central

    Yücesoy, Mine; Marol, Serhat

    2003-01-01

    Background The importance of identifying the pathogenic fungi rapidly has encouraged the development of differential media for the presumptive identification of yeasts. In this study two differential media, CHROMagar Candida and bismuth sulphite glucose glycine yeast agar, were evaluated for the presumptive identification of yeast species. Methods A total number of 270 yeast strains including 169 Candida albicans, 33 C. tropicalis, 24 C. glabrata, 18 C. parapsilosis, 12 C. krusei, 5 Trichosporon spp., 4 C. kefyr, 2 C. lusitaniae, 1 Saccharomyces cerevisiae and 1 Geotrichum candidum were included. The strains were first identified by germ tube test, morphological characteristics on cornmeal tween 80 agar and Vitek 32 and API 20 C AUX systems. In parallel, they were also streaked onto CHROMagar Candida and bismuth sulphite glucose glycine yeast agar plates. The results were read according to the color, morphology of the colonies and the existance of halo around them after 48 hours of incubation at 37°C. Results The sensitivity and specificity values for C. albicans strains were found to be 99.4, 100% for CHROMagar Candida and 87.0, 75.2% for BiGGY agar, respectively. The sensitivity of CHROMagar Candida to identify C. tropicalis, C. glabrata and C. krusei ranged between 90.9 and 100% while the specificity was 100%. The sensitivity rates for BiGGY agar were 66.6 and 100% while the specificity values were found to be 95.4 and 100% for C. tropicalis and C. krusei, respectively. Conclusions It can be concluded that the use of CHROMagar Candida is an easy and reliable method for the presumptive identification of most commonly isolated Candida species especially C. albicans, C. tropicalis and C. krusei. The lower sensitivity and specificity of BiGGY agar to identify commonly isolated Candida species potentially limits the clinical usefulness of this agar. PMID:14613587

  16. Thermal conductivity of a graphite bipolar plate (BPP) and its thermal contact resistance with fuel cell gas diffusion layers: Effect of compression, PTFE, micro porous layer (MPL), BPP out-of-flatness and cyclic load

    NASA Astrophysics Data System (ADS)

    Sadeghifar, Hamidreza; Djilali, Ned; Bahrami, Majid

    2015-01-01

    This paper reports on measurements of thermal conductivity of a graphite bipolar plate (BPP) as a function of temperature and its thermal contact resistance (TCR) with treated and untreated gas diffusion layers (GDLs). The thermal conductivity of the BPP decreases with temperature and its thermal contact resistance with GDLs, which has been overlooked in the literature, is found to be dominant over a relatively wide range of compression. The effects of PTFE loading, micro porous layer (MPL), compression, and BPP out-of-flatness are also investigated experimentally. It is found that high PTFE loadings, MPL and even small BPP out-of-flatness increase the BPP-GDL thermal contact resistance dramatically. The paper also presents the effect of cyclic load on the total resistance of a GDL-BPP assembly, which sheds light on the behavior of these materials under operating conditions in polymer electrolyte membrane fuel cells.

  17. The Resazurin-Agar Method - a Quick Test to Determine Water Quality

    NASA Astrophysics Data System (ADS)

    Huckfeldt, J.; Westphal, B.; Claußen, L.

    2015-12-01

    Rezasurin has been used as a smart tracer in stream ecosystems to indicate metabolic activity, specifically aerobic respiration by heterotrophic bacteria. Resazurin is a blue compound which is irreversibly reduced to the pink resorufin in the presence of aerobic bacteria. The degree and speed of colour change from blue to pink is a measure of the degree of oxygen consumption and thus an indirect indication of the concentration of aerobic bacteria in a given medium. A high concentration of bacteria in water indicates a bad water quality. In our work a method was developed using resazurin agar plates to find a quick and easy way for testing water quality and comparing concentrations of bacteria in freshwater and seawater samples. The theory was to concentrate bacteria from a defined volume of water sample onto polycarbonate filters (0.2 μm), which are then placed onto the resazurin agar plate. The presence of aerobic bacteria on the filter will reduce the resazurin in the agar and the compound changes its colour. First tests conducted with different dilutions of a pure culture of yoghurt bacteria showed promising results and confirmed the feasibility of the method. In a further assay, we used water samples from different water layers and different temperatures and were also able to observe differences in the concentration of bacteria, depending on these different environmental conditions.The assay was also successfully used with seawater samples, collected from 2 different stations at 3 different depths in the Baltic Sea (salinity=15). The discolouration of the plates showed good correlation with the oxygen concentrations in the water. The resazurin-agar plate method is economical and fast. Several samples could be investigated at the same time without sacrificing the reliability of the results. Thus it is a good pre-screening test for a quantitative evaluation of bacteria in a water sample.

  18. Comparison of sorbitol MacConkey and hemorrhagic coli agars for recovery of Escherichia coli O157:H7 from brie, ice cream, and whole milk.

    PubMed

    Hammack, T S; Feng, P; Amaguaña, R M; June, G A; Sherrod, P S; Andrews, W H

    1997-01-01

    The relative efficacies of hemorrhagic coli (HC) agar and several formulations of sorbitol MacConkey (SorMac) agar, with and without 0.1% (w/v) 4-methyllumbelliferyl-beta-D-glucuronide (MUG), in recovering unstressed and heat-stressed Escherichia coli O157:H7 from Brie cheese, ice cream, and whole milk were determined. Recovery of unstressed E. coli O157:H7 was determined quantitatively by spread-plating diluted samples onto different agars and performing plate counts. Recovery of stressed E. coli O157:H7 was determined qualitatively by enriching samples in modified trypticase soy broth, streaking the incubated enrichments, and isolating E. coli O157:H7 colonies from the agars. HC agar and the SorMac agar formulations did not differ significantly in their ability to recover unstressed E. coli O157:H7 from ice cream and whole milk; however, HC agar recovered significantly more unstressed E. coli O157:H7 from Brie cheese than did the SorMac agar formulations. Bacteriological Analytical Manual and Oxoid SorMac agar formulations made from individual ingredients, did not differ significantly in recovering unstressed E. coli O157:H7 from Brie cheese. The efficiency of the commercially available Oxoid SorMac agar could not be determined because of overgrowth by indigenous microflora. HC and SorMac agars did not differ significantly in recovering stressed E. coli O157:H7 from Brie cheese, ice cream, and whole milk. MUG had no apparent effect on recovery of either stressed or unstressed E. coli O157:H7 from the dairy foods examined.

  19. Ultrasonic backscatter coefficients for weakly scattering, agar spheres in agar phantoms

    PubMed Central

    King, Michael R.; Anderson, Janelle J.; Herd, Maria-Teresa; Ma, Darryl; Haak, Alexander; Wirtzfeld, Lauren A.; Madsen, Ernest L.; Zagzebski, James A.; Oelze, Michael L.; Hall, Timothy J.; O’Brien, William D.

    2010-01-01

    Applicability of ultrasound phantoms to biological tissue has been limited because most phantoms have generally used strong scatterers. The objective was to develop very weakly scattering phantoms, whose acoustic scattering properties are likely closer to those of tissues and then compare theoretical simulations and experimental backscatter coefficient (BSC) results. The phantoms consisted of agar spheres of various diameters (nominally between 90 and 212 μm), containing ultrafiltered milk, suspended in an agar background. BSC estimates were performed at two institutions over the frequency range 1–13 MHz, and compared to three models. Excellent agreement was shown between the two laboratory results as well as with the three models. PMID:20707460

  20. High-precision drop shape analysis (HPDSA) of quasistatic contact angles on silanized silicon wafers with different surface topographies during inclining-plate measurements: Influence of the surface roughness on the contact line dynamics

    NASA Astrophysics Data System (ADS)

    Heib, F.; Hempelmann, R.; Munief, W. M.; Ingebrandt, S.; Fug, F.; Possart, W.; Groß, K.; Schmitt, M.

    2015-07-01

    Contact angles and wetting of solid surfaces are strongly influenced by the physical and chemical properties of the surfaces. These influence quantities are difficult to distinguish from each other if contact angle measurements are performed by measuring only the advancing θa and the receding θr contact angle. In this regard, time-dependent water contact angles are measured on two hydrophobic modified silicon wafers with different physical surface topographies. The first surface is nearly atomically flat while the second surface is patterned (alternating flat and nanoscale rough patterns) which is synthesized by a photolithography and etching procedure. The different surface topographies are characterized with atomic force microscopy (AFM), Fourier transform infrared reflection absorption spectroscopy (FTIRRAS) and Fourier transform infrared attenuated total reflection spectroscopy (FTIR-ATR). The resulting set of contact angle data obtained by the high-precision drop shape analysis approach is further analyzed by a Gompertzian fitting procedure and a statistical counting procedure in dependence on the triple line velocity. The Gompertzian fit is used to analyze overall properties of the surface and dependencies between the motion on the front and the back edge of the droplets. The statistical counting procedure results in the calculation of expectation values E(p) and standard deviations σ(p) for the inclination angle φ, contact angle θ, triple line velocity vel and the covered distance of the triple line dis relative to the first boundary points XB,10. Therefore, sessile drops during the inclination of the sample surface are video recorded and different specific contact angle events in dependence on the acceleration/deceleration of the triple line motion are analyzed. This procedure results in characteristically density distributions in dependence on the surface properties. The used procedures lead to the possibility to investigate influences on contact

  1. Biological treatment of textile dyes by agar-agar immobilized consortium in a packed bed reactor.

    PubMed

    Patel, Yogesh; Gupte, Akshaya

    2015-03-01

    The decolorization of Acid Maroon V was investigated using bacterial consortium EDPA containing Enterobacter dissolvens AGYP1 and Pseudomonas aeruginosa AGYP2 immobilized in different entrapment matrices. The consortium displayed 96% removal of dye (100 mg/l) within 6 h when immobilized in agar-agar. Under optimum concentrations of agar-agar (3.0% w/v) and cell biomass (0.9 g% w/v), the consortium displayed decolorization for 18 successive batches of Acid Maroon V and also decolorized 14 other different textile dyes. A packed bed reactor under batch mode showed 89% decolorization of dye after 56 repetitive cycles. Under continuous flow mode, maximum color removal was achieved with bed length of 36 cm, hydraulic retention time of 2.66 h, and dye concentration of 100 mg/l. Additionally, the reactor decolorized relatively higher concentrations (100-2000 mg/l) of dye. The synthetic dye wastewater containing five textile dyes was decolorized 92% with 62% COD reduction using an immobilized consortium.

  2. Radiation survival of murine and human melanoma cells utilizing two assay systems: monolayer and soft agar.

    PubMed Central

    Yohem, K. H.; Slymen, D. J.; Bregman, M. D.; Meyskens, F. L.

    1988-01-01

    The radiation response of murine and human melanoma cells assayed in bilayer soft agar and monolayer was examined. Cells from the murine melanoma Cloudman S91 CCL 53.1 cell line and three human melanoma cell strains (C8146C, C8161, and R83-4) developed in our laboratory were irradiated by single dose X-rays and plated either in agar or on plastic. D0 values were the same within 95% confidence intervals for cells from the human melanoma cell strains C8146C, C8161, and R83-4 but were dissimilar for the murine cell line CCL 53.1 Dq values were different for all cells studied. The shape of the survival curve for all four melanomas was not identical for cells assayed in soft agar versus cells grown on plastic. This would indicate that apparent radiosensitivity was influenced by the method of assay although there were no apparent consistent differences between the curves generated by monolayer or bilayer soft agar assays. PMID:3348949

  3. Screening fungicides for use in fish culture: Evaluation of the agar plug transfer, cellophane transfer, and agar dilution methods

    USGS Publications Warehouse

    Bailey, Tom A.

    1983-01-01

    The reliability, reproducibility, and usefulness of three screening methods -- the cellophane transfer, the agar plug transfer, and the agar dilution -- to screen aquatic fungicides were evaluated. Achlya flagellata and Saprolegnia hypogyna were exposed to 1, 10, and 100 mg/L of malachite green to test each method. The cellophane transfer and agar plug transfer techniques had similar reliability and reproducibility in rating fungicidal activity, and were both superior to the agar dilution technique. The agar plug transfer and agar dilution techniques adequately projected in vivo activity of malachite green, but the cellophane transfer technique overestimated its activity. Overall, the agar plug transfer technique most accurately rated the activity of malachite green and was the easiest test to perform. It therefore appears to be the method of choice for testing aquatic fungicides.

  4. Comparative evaluation of chromogenic agar medium and conventional culture system for isolation and presumptive identification of uropathogens

    PubMed Central

    Akter, Laila; Haque, Rezwana; Salam, Md. Abdus

    2014-01-01

    Objective: Urine is the most frequent specimen received for culture/sensitivity by clinical laboratories. The microbiological performance of HiCrome UTI agar medium was compared with Blood agar and MacConkey agar for isolation and presumptive identification of bacteria from urine culture. Methods: A total of 443 consecutively collected midstream and/or catheter-catch urine samples from patients attending the Islami Bank Medical College Hospital, Rajshahi, Bangladesh during January to December, 2012 were cultured. Urine samples showing pus cells ≥ 5/HPF were inoculated on to Blood agar (BA), MacConkey agar (MAC) and HiCrome UTI agar (CA) media simultaneously and incubated overnight aerobically at 370C. Rate of isolation and presumptive identification of bacterial species were compared for different media. Results: Culture yielded a total of 199 bacterial isolates from 189 (42.67%) positive plates including 179 (40.40%) unimicrobial and 10 (2.26%) polymicrobial (mixed growth of pair of bacteria) growths. Both HiCrome UTI agar and Blood agar media supported 100% growths while 151 (75.88%) growths were observed on MacConkey agar. The rate of presumptive identification was found significantly higher on HiCrome UTI agar (97.49%) than MAC agar (67.34%) (P<0.001) as primary urine culture medium. Of 199 isolates, E. coli was found to be the leading uropathogen isolated from 118 (59.30%) samples with its presumptive identification rate of 95.76%, 93.22% and 5.93% on CA, MAC and BA respectively. All 10 (100%) polymicrobial growths were demonstrated distinctly on CA against only 01(10%) on each BA and MAC. Conclusion: HiCrome UTI agar was found to be more useful as primary urine culture medium in both higher rate of isolation and presumptive identification of uropathogens in comparison to conventional media. Its inherent characteristics in demonstrating polymicrobial growth and ease of rapid identification by distinct colony colour are unique. PMID:25225521

  5. Improving agar electrospinnability with choline-based deep eutectic solvents.

    PubMed

    Sousa, Ana M M; Souza, Hiléia K S; Uknalis, Joseph; Liu, Shih-Chuan; Gonçalves, Maria P; Liu, LinShu

    2015-09-01

    Very recently our group has produced novel agar-based fibers by an electrospinning technique using water as solvent and polyvinyl alcohol (PVA) as co-blending polymer. Here, we tested the deep eutectic solvent (DES), (2-hydroxyethyl)trimethylammonium chloride/urea prepared at 1:2 molar ratio, as an alternative solvent medium for agar electrospinning. The electrospun materials were collected with an ethanol bath adapted to a previous electrospinning set-up. One weight percent agar-in-DES showed improved viscoelasticity and hence, spinnability, when compared to 1 wt% agar-in-water and pure agar nanofibers were successfully electrospun if working above the temperature of sol-gel transition (∼80 °C). By changing the solvent medium we decreased the PVA concentration (5 wt% starting solution) and successfully produced composite fibers with high agar contents (50/50 agar/PVA). Best composite fibers were formed with the 50/50 and 30/70 agar/PVA solutions. These fibers were mechanically resistant, showed tailorable surface roughness and diverse size distributions, with most of the diameters falling in the sub-micron range. Both nano and micro forms of agar fibers (used separately or combined) may have potential for the design of new and highly functional agar-based materials.

  6. Automatic Surface Inoculation of Agar Trays1

    PubMed Central

    Wilkins, Judd R.; Mills, Stacey M.; Boykin, Elizabeth H.

    1972-01-01

    A machine is described which automatically inoculates a plastic tray containing agar media with a culture by use of either a conventional inoculating loop or a cotton swab. Isolated colonies were obtained with an inoculating loop when a heavy inoculum (109 cells/ml) was used or with a cotton swab when a light inoculum (ca. 104 cells/ml) was used. Trays containing combinations of differential or selective media were used to (i) separate mixtures of gram-positive and gram-negative bacteria, (ii) facilitate isolation of organisms from clinical specimens, and (iii) compare colony growth characteristics of pure cultures. The design of the machine is simple, it is easy to use, and it relieves the operator from the manual task of streaking cultures. Images PMID:16349943

  7. Poisoning with brown fly agaric, Amanita regalis.

    PubMed

    Elonen, E; Tarssanen, L; Härkönen, M

    1979-01-01

    Three patients ate different amounts of a common northern mushroom, brown fly agaric, Amanita regalis. All of them believed they had eaten delicious parasol mushrooms, Macrolepiota procera. The symptoms of poisoning began 1--2 hours after ingestion of the mushrooms. All the patients had marked gastrointestinal symptoms: nausea and heavy vomiting. Two had central nervous system manifestations and cholinergic symptoms: hallucinations, confusion, or loss of consciousness as well as copious salivation, or sweating. All patients recovered within 4--24 hours without any damage to liver, kidneys or central nervous system. It seems that cooking the mushrooms does not completely neutralize the toxic agents of Amanita regalis. The analysis of fried mushrooms shows that it may be possible to identify mushrooms reliably from the remains of a meal.

  8. The effect of nanocomposite polymeric layer on the radiation of antisymmetric zero-order Lamb wave in a piezoelectric plate contacting with liquid

    NASA Astrophysics Data System (ADS)

    Kuznetsova, I. E.; Zaitsev, B. D.; Borodina, I. A.; Shikhabudinov, A. M.; Teplykh, A. A.; Manga, E.; Feuillard, G.

    2013-06-01

    A nanocomposite polymeric layer is proposed to be used for increasing the efficiency of ultrasound radiation into the liquid by antisymmetric zero-order (A0) Lamb waves propagating in piezoelectric plates. The theoretical and experimental investigations of the influence of the nanocomposite polymeric layers on the efficiency and radiation angle of acoustic wave into liquid were carried out. It has been theoretically shown that the use of the layer of the polyethylene of low density with nanoparticles of cadmium sulfide of concentration 25% between the plate of 128YX LiNbO3 and water medium allows to increase the radiation attenuation on ˜1 dB/λ if the ratio of the thicknesses of the layer and plate is equal to 0.16 at the frequency of 1.3 MHz. The experimental data were in a good agreement with theoretical results. It has been also shown that the presence of nanocomposite film leads to the increase of the radiation angle of bulk acoustic wave in liquid and allows the effective operation of the radiator not only in the sweet water but also in salt one. The obtained results may be used for the development of effective radiators/receivers of acoustic waves in liquids for flow meters and for underwater communication systems.

  9. Reliability of the agar based method to assess the production of degradative enzymes in clinical isolates of Candida albicans.

    PubMed

    Arantes, Paula Tamião; Sanitá, Paula Volpato; Santezi, Carolina; Barbeiro, Camila de Oliveira; Reina, Bárbara Donadon; Vergani, Carlos Eduardo; Dovigo, Lívia Nordi

    2016-03-01

    The aim of this study was to establish a reproducible protocol using the methodology of hyaline zones around the colonies on specific agar plates for phospholipase and proteinase production. This was an in vitro double-blind experiment, in which the dependent variables were the enzymatic activity measurements (Pz) for the production of phospholipase (Pz-ph) and the production of secreted aspartyl proteinases (Pz-sap). Three independent variables give rise to different measurement protocols. All measurements were carried out at two different moments by four examiners (E1, E2, E3, and E4). The minimum sample size was 30 Candida albicans clinical isolates. Specific agar plates for phospholipase and SAPs production were prepared according the literature. The intra-and inter-examiner reproducibility for each protocol was estimated using the Intraclass Correlation Coefficient (ICC) and its confidence interval (95% CI). Based on the results obtained for both phospholipase and SAPs, there appears to be no consensus on the protocol chosen for each particular examiner. Measuring the colonies in triplicate may be the main factor associated with the increase in measurement accuracy and should therefore take precedence over measuring only one colony. When only one examiner is responsible for taking measurements, a standard protocol should be put in place and the statistical calibration of this researcher should be done prior to data collection. However, if two or more researchers are involved in the assessment of agar plates, our results suggest that the protocols using software to undertake plate reading is preferred.

  10. Contact Problem on the Interaction of Two Lap Plates, Absolutely Rigid in Tension and Flexible in Bending, with a Thin Circular Sector

    NASA Astrophysics Data System (ADS)

    Sargsyan, A. M.

    2017-03-01

    Using the Fourier method, a solution is constructed for the boundary-value problem of elasticity theory for a circular sector whose radial sides are reinforced by two lap plates absolutely rigid in tension and flexible in bending. On the arc part of its contour, external conditions are given. The stress singularity in the vicinity of top of the circular sector and the behavior of coefficients of the singularity are investigated. It is established that stresses in this vicinity have a singularity of the type r -1+ ɛ ( ɛ > 0; ɛ → 0 at α → π or α → 2 π), whose coefficients, in the general case of loading of the arc part of the sector, differ from zero, which is inadmissible from the viewpoint of the mechanics of brittle fracture. However, an appropriate selection of external conditions on the arc part of sector allows one to equate these coefficients to zero.

  11. Micro-agar salt bridge in patch-clamp electrode holder stabilizes electrode potentials

    PubMed Central

    Shao, Xuesi M.; Feldman, Jack L.

    2015-01-01

    Maintaining a stable electrode potential is critical for patch-clamp measurements. The electrode potential of conventional patch electrode-holder assembly, where an Ag/AgCl wire is in direct contact with the patch pipette filling solution, is subject to drift if the pipette solution contains a low concentration of chloride ions (Cl−). We developed an agar bridge of 3 M KCl filled in a polyimide microtubing which forms an electrical connection between an Ag/AgCl wire and the pipette solution. We examined the offset potentials of the micro-agar salt bridge electrode assembly in parallel with a conventional electrode assembly in generic recording conditions (the pipette solution contained 5 mM NaCl). The junction potential between the Ag/AgCl wire and the pipette filling solution in the conventional electrode contributed to most of the offset potential drift observed during the course of 30 min recordings. The drift was up to 27.3 mV after several changes of the glass pipette. In contrast, the micro-agar salt bridge stabilized the electrode potential within typically 2 mV without affecting the patch electrode resistance, capacitance or noise level. Numerical simulations showed that Cl− diffusion from the agar bridge to the tip caused a negligible 0.4 μM Cl− concentration change at the pipette tip within 30 min. This method is easy to implement and provides long-term recording stability. The micro-agar salt bridge can fit in most commercial patch electrode holders and can be conveniently maintained. PMID:16916545

  12. Contact dermatitis

    MedlinePlus

    Dermatitis - contact; Allergic dermatitis; Dermatitis - allergic; Irritant contact dermatitis; Skin rash - contact dermatitis ... There are 2 types of contact dermatitis. Irritant dermatitis: This ... can be by contact with acids, alkaline materials such as soaps ...

  13. Selected elements in fly agaric Amanita muscaria.

    PubMed

    Falandysz, J; Kunito, T; Kubota, R; Lipka, K; Mazur, A; Falandysz, Justyna J; Tanabe, S

    2007-09-01

    Concentrations of Ag, Al, Ba, Ca, Cd, Co, Cu, Cr, Cs, Fe, Ga, Hg, K, Mg, Mn, Mo, Na, Pb, Rb, Se, Sb, Sr, V, Tl and Zn have been determined in the whole fruiting bodies, as well as separately in caps and stalks, of fly agaric collected from three geographically distant sites in northern part of Poland. The elements were determined using ICP-MS, ICP-OES, HG-AAS and CV-AAS, respectively. For elements such as Al, Ba, Cr, Fe, Ga, Mo, Mn, Pb, Sb, Sr, Tl, and V concentrations were similar in the caps and stalks, respectively, and for K, Zn, Ag, Ca, Cd, Cu, Hg, Mg, Rb and Se were greater in the caps, while for Co, Cs and Na in the stalks. For Ag, Al, Ba, Ca, Cd, Co, Cr, Cs, Fe, Ga, Hg, Mn, Mo, Pb, Rb, Sb, Sr, Tl and V concentration in the caps showed spatial variations (P<0.05), while for Cu, K, Mg, Na, Se and Zn was independent of the site. The elements such as K with median or mean in the caps between 37,000 and 43,000 microg/g.dm and Mg with 920 and 1,100 microg/g dm were most abundant. Next, within median values range from approximately 100 to 500 microg/g dm were such as Ca, Fe and Al, and in descending order they followed by Rb (100-400 microg/g dm); V, Na, Zn (50-200 microg/g dm); Cu, Mn (10-50 microg/g dm); Cd (10-20 microg/g dm); Se (5 microg/g dm); Ba (<1-3); Cr, Ag, Pb, Sr (<1-2 microg/g dm); Cs, Co, Hg (<1-1 microg/g dm); Ga (<0.5), Sb, Mo and Tl (<0.1 microg/g dm).

  14. Isolation and characterization of agar-digesting Vibrio species from the rotten thallus of Gracilariopsis heteroclada Zhang et Xia.

    PubMed

    Martinez, Joval N; Padilla, Philip Ian P

    2016-08-01

    Gracilariopsis heteroclada Zhang et Xia (Gracilariaceae, Rhodophyta) is one of the most studied marine seaweeds due to its economic importance. This has been cultivated extensively on commercial scale in the Philippines and other Asian countries. However, sustainable production of G. heteroclada in the Philippines could not be maximized due to the occurrence of rotten thallus disease. Thus, isolation and characterization of agar-digesting bacteria from the rotten thalli of G. heteroclada was conducted. A total of seven representative bacterial isolates were randomly selected based on their ability to digest agar as evidenced by the formation of depressions around the bacterial colonies on nutrient agar plates supplemented with 1.5% NaCl and liquefaction of agar. Gram-staining and biochemical characterization revealed that isolates tested were gram-negative rods and taxonomically identified as Vibrio parahaemolyticus (86-99.5%) and Vibrio alginolyticus (94.2-97.7%), respectively. It is yet to be confirmed whether these agar-digesting vibrios are involved in the induction and development of rotten thallus disease in G. heteroclada in concomitance with other opportunistic bacterial pathogens coupled with adverse environmental conditions.

  15. Campylobacter in broiler slaughter samples assessed by direct count on mCCDA and Campy-Cefex agar.

    PubMed

    Gonsalves, Camila Cristina; Borsoi, Anderlise; Perdoncini, Gustavo; Rodrigues, Laura Beatriz; do Nascimento, Vladimir Pinheiro

    2016-01-01

    Campylobacter spp. cause foodborne illnesses in humans primarily through the consumption of contaminated chicken. The aim of this study was to evaluate the United States Department of Agriculture's (USDA) recommended methodology, protocol MLG 41.02, for the isolation, identification and direct plate counting of Campylobacter jejuni and C. coli samples from the broiler slaughtering process. A plating method using both mCCDA and Campy-Cefex agars is recommended to recover Campylobacter cells. It is also possible to use this method in different matrices (cloacal swabs and water samples). Cloacal swabs, samples from pre-chiller and post-chiller carcasses and samples of pre-chiller, chiller and direct supply water were collected each week for four weeks from the same flock at a slaughterhouse located in an abattoir in southern Brazil. Samples were analyzed to directly count Campylobacter spp., and the results showed a high frequency of Campylobacter spp. on Campy-Cefex agar. For the isolated species, 72% were identified as Campylobacter jejuni and 38% as Campylobacter coli. It was possible to count Campylobacter jejuni and Campylobacter coli from different samples, including the water supply samples, using the two-agar method. These results suggest that slaughterhouses can use direct counting methods with both agars and different matrices as a monitoring tool to assess the presence of Campylobacter bacteria in their products.

  16. Comparison of inhibitory mold agar to Sabouraud dextrose agar as a primary medium for isolation of fungi.

    PubMed

    Scognamiglio, Theresa; Zinchuk, Riva; Gumpeni, Pramod; Larone, Davise H

    2010-05-01

    Clinical specimens cultured on two selective fungal media, inhibitory mold agar (IMA) and Sabouraud dextrose agar (SDA), were compared with respect to recovery of fungi. Of the 840 fungal isolates recovered, 69.3% grew on both IMA and SDA; 24.9% grew only on IMA; and 5.8% grew only on SDA, showing that IMA is superior (P=0.003).

  17. Fuel cell end plate structure

    DOEpatents

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  18. Effect of assembly error of bipolar plate on the contact pressure distribution and stress failure of membrane electrode assembly in proton exchange membrane fuel cell

    NASA Astrophysics Data System (ADS)

    Liu, Dong'an; Peng, Linfa; Lai, Xinmin

    In practice, the assembly error of the bipolar plate (BPP) in a PEM fuel cell stack is unavoidable based on the current assembly process. However its effect on the performance of the PEM fuel cell stack is not reported yet. In this study, a methodology based on FEA model, "least squares-support vector machine (LS-SVM)" simulation and statistical analysis is developed to investigate the effect of the assembly error of the BPP on the pressure distribution and stress failure of membrane electrode assembly (MEA). At first, a parameterized FEA model of a metallic BPP/MEA assembly is established. Then, the LS-SVM simulation process is conducted based on the FEA model, and datasets for the pressure distribution and Von Mises stress of MEA are obtained, respectively for each assembly error. At last, the effect of the assembly error is obtained by applying the statistical analysis to the LS-SVM results. A regression equation between the stress failure and the assembly error is also built, and the allowed maximum assembly error is calculated based on the equation. The methodology in this study is beneficial to understand the mechanism of the assembly error and can be applied to guide the assembly process for the PEM fuel cell stack.

  19. Selection of brain metastasis-initiating breast cancer cells determined by growth on hard agar.

    PubMed

    Guo, Lixia; Fan, Dominic; Zhang, Fahao; Price, Janet E; Lee, Ju-Seog; Marchetti, Dario; Fidler, Isaiah J; Langley, Robert R

    2011-05-01

    An approach that facilitates rapid isolation and characterization of tumor cells with enhanced metastatic potential is highly desirable. Here, we demonstrate that plating GI-101A human breast cancer cells on hard (0.9%) agar selects for the subpopulation of metastasis-initiating cells. The agar-selected cells, designated GI-AGR, were homogeneous for CD44(+) and CD133(+) and five times more invasive than the parental GI-101A cells. Moreover, mice injected with GI-AGR cells had significantly more experimental brain metastases and shorter overall survival than did mice injected with GI-101A cells. Comparative gene expression analysis revealed that GI-AGR cells were markedly distinct from the parental cells but shared an overlapping pattern of gene expression with the GI-101A subline GI-BRN, which was generated by repeated in vivo recycling of GI-101A cells in an experimental brain metastasis model. Data mining on 216 genes shared between GI-AGR and GI-BRN breast cancer cells suggested that the molecular phenotype of these cells is consistent with that of cancer stem cells and the aggressive basal subtype of breast cancer. Collectively, these results demonstrate that analysis of cell growth in a hard agar assay is a powerful tool for selecting metastasis-initiating cells in a heterogeneous population of breast cancer cells, and that such selected cells have properties similar to those of tumor cells that are selected based on their potential to form metastases in mice.

  20. The use of agar as a novel filler for monolithic matrices produced using hot melt extrusion.

    PubMed

    Lyons, John G; Devine, Declan M; Kennedy, James E; Geever, Luke M; O'Sullivan, Patrick; Higginbotham, Clement L

    2006-08-01

    The use of filler materials in an extended release monolithic polymer matrix can lead to a vastly altered release profile for the active pharmaceutical ingredient. A range of excipients for use in monolithic matrices have been discussed in the literature. The body of work described in this research paper outlines the use of agar as a novel filler material in a hot melt extruded polymer matrix. Several batches of matrix material were prepared with Diclofenac sodium used as the active pharmaceutical ingredient (API). Agar and microcrystalline cellulose were used as the filler materials in varying ratios, to examine the effect of % filler content as well as filler type on the properties of the hot melt extruded matrix. The resultant extrudates were characterised using steady state parallel plate rheometry, differential scanning calorimetry (DSC) and dissolution testing. The rheometry analysis concluded that the fillers used resulted in an increase in the matrix viscosity. The DSC scans obtained showed negligible effects on the melting behavior of the matrix as a result of the filler inclusion. Dissolution analysis showed that the presence of the fillers resulted in a slower release rate of API than for the matrix alone. The results detailed within this paper indicate that agar is a viable filler for extended release hot melt produced dosage forms.

  1. Differentiation of Candida dubliniensis from Candida albicans on rosemary extract agar and oregano extract agar.

    PubMed

    de Loreto, Erico Silva; Pozzatti, Patrícia; Alves Scheid, Liliane; Santurio, Deise; Morais Santurio, Janio; Alves, Sydney Hartz

    2008-01-01

    Candida dubliniensis is a recently described pathogenic species which shares many phenotypic features with Candida albicans and therefore, may be misidentified in microbiological laboratories. Because molecular methods can be onerous and unfeasible in routine mycological laboratories with restricted budgets such as those in developing countries, phenotypic techniques have been encouraged in the development of differential media for the presumptive identification of these species. We examined the colony morphology and chlamydospore production of 30 C. dubliniensis isolates and 100 C. albicans isolates on two new proposed media: rosemary (Rosmarinus officinalis) extract agar (REA) and oregano (Origanum vulgare) extract agar (OEA). These substrates are traditionally used as spices and medicinal herbs. In both of these media, all C. dubliniensis isolates (100%) showed rough colonies with peripheral hyphal fringes and abundant chlamydospores after 24 to 48 hr of incubation at 25 degrees C. In contrast, under the same conditions, all isolates of C. albicans (100%) showed smooth colonies without hyphal fringes or chlamydospores. In conclusion, REA and OEA offer a simple, rapid, and inexpensive screening media for the differentiation of C. albicans and C. dubliniensis.

  2. Degradation of SS316L bipolar plates in simulated fuel cell environment: Corrosion rate, barrier film formation kinetics and contact resistance

    NASA Astrophysics Data System (ADS)

    Papadias, Dionissios D.; Ahluwalia, Rajesh K.; Thomson, Jeffery K.; Meyer, Harry M.; Brady, Michael P.; Wang, Heli; Turner, John A.; Mukundan, Rangachary; Borup, Rod

    2015-01-01

    A potentiostatic polarization method is used to evaluate the corrosion behavior of SS316L in simulated anode and cathode environments of polymer electrolyte fuel cells. A passive barrier oxide film is observed to form and reach steady state within ∼10 h of polarization, after which time the total ion release rates are low and nearly constant at ∼0.4 μg cm-2 h-1 for all potentials investigated. The equilibrium film thickness, however, is a function of the applied potential. The main ionic species dissolved in the liquid are predominately Fe followed by Ni, that account for >90% of the steady-state corrosion current. The dissolution rate of Cr is low but increases systematically at potentials higher than 0.8 V. The experimental ion release rates can be correlated with a point defect model using a single set of parameters over a broad range of potentials (0.2-1 V) on the cathode side. The interfacial contact resistance measured after 48 h of polarization is observed to increase with increase in applied potential and can be empirically correlated with applied load and oxide film thickness. The oxide film is substantially thicker at 1.5 V possibly because of alteration in film composition to Fe-rich as indicated by XPS data.

  3. Effect of water structure on gelation of agar in glycerol solutions and phase diagram of agar organogels.

    PubMed

    Boral, Shilpi; Bohidar, H B

    2012-06-21

    A comprehensive study of hydration of polyanionic agar molecules in its solution and gel phase in glycerol-water binary solvent is reported. Raman spectroscopy results predict differential water structure arrangement for glycerol-water binary solvent, 0.02% (w/v) agar in glycerol solution and 0.3% (w/v) agar organogel. The 3200 cm(-1) Raman band pertaining to ice-like structure of water was found to increase in gel phase alike in glycerol-water solvent while it decreased in agar solutions with increase in glycerol concentration. In contrast, the partially structured water corresponding to the component 3310 cm(-1) of Raman spectra increased in agar solution, and decreased in gel phase similar to glycerol-water solvent case. We have explained these observations based on a simple model where the available oxygen to hydrogen atom ratio in a given solvent-polymer system uniquely defines hydration in solution and gel phases. The gelation concentration was found to increase from 0.18 (for water) to 0.22% (w/v) (50% v/v glycerol solution) as the glycerol concentration was raised. Correspondingly, the gelation temperature, T(g), showed a decline from 40 to 20 °C, and the gel melting temperature, T(m), revealed a reduction from 81 to 65 °C in the same glycerol concentration regime. Two distinctive features are evident here: (i) presence of glycerol as a cosolvent does not favor the gelation of agar as compared to water and (ii) agar organogels are softer than their hydrogels. A unique 3D phase diagram for the agar organogel is proposed. Circular dichroism data confirmed that the agar molecules retained their biological activity in these solvents. Thus, it is shown that thermo-mechanical properties of these organogels could be systematically tuned and adapted as per application requirement.

  4. Plate motion

    SciTech Connect

    Gordon, R.G. )

    1991-01-01

    The motion of tectonic plates on the earth is characterized in a critical review of U.S. research from the period 1987-1990. Topics addressed include the NUVEL-1 global model of current plate motions, diffuse plate boundaries and the oceanic lithosphere, the relation between plate motions and distributed deformations, accelerations and the steadiness of plate motions, the distribution of current Pacific-North America motion across western North America and its margin, plate reconstructions and their uncertainties, hotspots, and plate dynamics. A comprehensive bibliography is provided. 126 refs.

  5. Evaluation of potassium-clavulanate-supplemented modified charcoal-cefoperazone-deoxycholate agar for enumeration of Campylobacter in chicken carcass rinse.

    PubMed

    Chon, Jung-Whan; Kim, Hong-Seok; Kim, Hyunsook; Oh, Deog-Hwan; Seo, Kun-Ho

    2014-05-01

    Potassium-clavulanate-supplemented modified charcoal-cefoperazone-deoxycholate agar (C-mCCDA) that was described in our previous study was compared with original mCCDA for the enumeration of Campylobacter in pure culture and chicken carcass rinse. The quantitative detection of viable Campylobacter cells from a pure culture, plated on C-mCCDA, is statistically similar (P > 0.05) to mCCDA. In total, 120 chickens were rinsed using 400 mL buffered peptone water. The rinses were inoculated onto C-mCCDA and mCCDA followed by incubation at 42 °C for 48 h. There was no statistical difference between C-mCCDA (45 of 120 plates; mean count, 145.5 CFU/mL) and normal mCCDA (46 of 120 plates; mean count, 160.8 CFU/mL) in the isolation rate and recovery of Campylobacter (P > 0.05) from chicken carcass rinse. The Pearson correlation coefficient value for the number of Campylobacter cells recovered in the 2 media was 0.942. However, the selectivity was much better on C-mCCDA than on mCCDA plates (P < 0.05). Significantly fewer C-mCCDA plates (33 out of 120 plates; mean count, 1.9 CFU/mL) were contaminated with non-Campylobacter cells than the normal mCCDA plates (67 out of 120 plates; mean count, 27.1 CFU/mL). The C-mCCDA may provide improved results for enumeration of Campylobacter in chicken meat alternative to mCCDA with its increased selectivity the modified agar possess.

  6. Use of agar/glycerol and agar/glycerol/water as a translucent brain simulant for ballistic testing.

    PubMed

    Falland-Cheung, Lisa; Waddell, J Neil; Lazarjan, Milad Soltanipour; Jermy, Mark C; Winter, Taylor; Tong, Darryl; Brunton, Paul A

    2017-01-01

    The suitability of agar/glycerol/water and agar/glycerol mixtures as brain simulants was investigated. Test specimens (n=15) (50x27×37mm) were fabricated for these different mixtures and conditioned to 12°C, 22°C, and 26°C prior to testing. For comparison, fresh deer brain specimens (n=20) were sourced and prepared to the same dimensions as the agar/glycerol(/water) mixtures and conditioned to 12°C and 37°C. High impact tests were carried out with a 0.22-caliber air rifle pellet and a high-speed camera was used to record the projectile as it passed through the specimens, allowing for energy loss and vertical displacement velocity calculation. Although the agar/glycerol/water mixture presented with similar vertical expansion and contraction of the specimens to the warm and cold deer brains, a two-fold decrease of the vertical expansion and contraction was noticed with the agar/glycerol specimens. Also considerably less extrusion of this mixture out of the exit and entry sides after specimen penetration was observed. Of the simulants tested, agar/glycerol/water was the most suitable brain simulant for ballistic testing and impact studies.

  7. Effects of immersion disinfection of agar-alginate combined impressions on the surface properties of stone casts.

    PubMed

    Iwasaki, Yukiko; Hiraguchi, Hisako; Iwasaki, Eriko; Yoneyama, Takayuki

    2016-01-01

    This study investigated the effects of disinfection of agar-alginate combined impressions on the surface properties of the resulting stone casts. Two brands of cartridge-form agar impression material and one alginate impression material were used. Agar-alginate combined impressions of smooth glass plates were prepared. The impressions were immersed in 0.55% ortho-phthalaldehyde solution or 0.5% sodium hypochlorite solution for 1, 3, 5 and 10 min. A stone cast made with an impression that had not been immersed was prepared as a control. The surface roughness (Ra) of the stone casts was measured, and the cast surfaces were observed by SEM. Immersion of agar-alginate combined impressions in 0.5% sodium hypochlorite solution for up to 10 min had no serious adverse effects on the surface properties of the stone casts. In contrast, even 1 min of immersion in 0.55% ortho-phthalaldehyde solution caused deterioration of the cast surface properties.

  8. Evaluation of Mueller-Hinton-agar as a simple medium for the germ tube production of Candida albicans and Candida dubliniensis.

    PubMed

    Rimek, Dagmar; Fehse, Brigitte; Göpel, Petra

    2008-05-01

    Candida albicans is the most frequently isolated yeast species from clinical specimens. A classical rapid presumptive differentiation from non-albicans species is based on its ability to produce germ tubes after incubation in human serum. The only non-albicans Candida species producing germ tubes is Candida dubliniensis. In this study, we evaluated Mueller-Hinton-agar (MH-agar) as a medium for germ tube formation of C. albicans and C. dubliniensis. A total of 859 yeast isolates from stool samples, including 632 strains of C. albicans, 10 C. dubliniensis and 217 other yeast strains from 20 different species, were grown on Sabouraud glucose (2%) agar at 37 degrees C for 24-72 h. Species were identified by standard methods. For the germ tube test (GTT), an inoculum from a single colony was streaked onto a MH-agar plate and covered by a sterile coverslip. After incubation at 37 degrees C for 2 h, the MH plates were examined using a light microscope at x200. The GTT was positive in 578 of 632 C. albicans strains (sensitivity 91.5%), in six of 10 C. dubliniensis strains (sensitivity 60.0%), and in none of the other yeast strains. MH-agar is a suitable medium for the GTT and the presumptive identification of C. albicans. It is safer to use than human serum and is widely available in microbiology laboratories.

  9. Physicochemical factors influencing bacterial transfer from contact lenses to surfaces with different roughness and wettability.

    PubMed

    Vermeltfoort, Pit B J; van der Mei, Henny C; Busscher, Henk J; Hooymans, Johanna M M; Bruinsma, Gerda M

    2004-11-15

    The aim of this study was to determine the transfer of Pseudomonas aeruginosa No. 3 and Staphylococcus aureus 835 from contact lenses to surfaces with different hydrophobicity and roughness. Bacteria were allowed to adhere to contact lenses (Surevue, PureVision, or Focus Night & Day) by incubating the lenses in a bacterial suspension for 30 min. The contaminated lenses were put on a glass, poly(methylmethacrylate), or silicone rubber substratum, shaped to mimic the eye. After 2 and 16 h, lenses were separated from the substrata and bacteria were swabbed off from the respective surfaces and resuspended in saline. Appropriate serial dilutions of these suspensions were made, from which aliquots were plated on agar for enumeration. Bacterial transfer varied between 4 and 60%, depending on the combination of strain, contact time, contact lens, and substratum surface. For P. aeruginosa No. 3, transfer was significantly higher after 16 h than after 2 h, whereas less increase with time was seen for S. aureus 835. Bacterial transfer from all tested contact lenses was least to silicone rubber, the most hydrophobic and roughest substratum surface included.

  10. Fly agaric (Amanita muscaria) poisoning, case report and review.

    PubMed

    Satora, Leszek; Pach, Dorota; Butryn, Beata; Hydzik, Piotr; Balicka-Slusarczyk, Barbara

    2005-06-01

    Gathering and eating mushrooms and other plants containing psychoactive substances has become increasingly popular among young people experimenting with drugs. Dried fly agaric Amanita muscaria fruiting bodies were eaten by five young persons (18-21 years of age) at a party in order to evoke hallucinations. Visual and auditory hallucinations occurred in four of them, whereas a 18-year-old girl lost consciousness. The following morning, she went to the Clinic of Toxicology. Due to the fact that not all the active substances present in the fly agaric have been identified, and some of them have an effect after a period of latency, the patient was admitted for several days of observation during which check-up examinations were performed. After four days without any problems, she was discharged. The poisoning regressed with no organ complications. The remaining persons who had eaten the fly agaric were free from any complaints.

  11. Lysine-iron agar in the detection of Arizona cultures.

    PubMed

    EDWARDS, P R; FIFE, M A

    1961-11-01

    A lysine-iron agar is described and recommended for the detection of Arizona strains which ferment lactose rapidly. Black colonies which appear on bismuth sulfite agar should be transferred to the medium. Salmonellae and Arizona cultures produce a distinctive reaction since they are the only recognized groups of enteric bacteria which regularly produce lysine decarboxylase rapidly and form large amounts of hydrogen sulfide. Use of the medium is particularly recommended in the examination of specimens from enteric infections in which shigellae and salmonellae are not detected.

  12. NICKEL PLATING PROCESS

    DOEpatents

    Hoover, T.B.; Zava, T.E.

    1959-05-12

    A simplified process is presented for plating nickel by the vapor decomposition of nickel carbonyl. In a preferred form of the invention a solid surface is nickel plated by subjecting the surface to contact with a mixture containing by volume approximately 20% nickel carbonyl vapor, 2% hydrogen sulfide and .l% water vapor or 1% oxygen and the remainder carbon dioxide at room temperature until the desired thickness of nickel is obtained. The advantage of this composition over others is that the normally explosive nickel carbonyl is greatly stabilized.

  13. Method for forming metal contacts

    DOEpatents

    Reddington, Erik; Sutter, Thomas C; Bu, Lujia; Cannon, Alexandra; Habas, Susan E; Curtis, Calvin J; Miedaner, Alexander; Ginley, David S; Van Hest, Marinus Franciscus Antonius Maria

    2013-09-17

    Methods of forming metal contacts with metal inks in the manufacture of photovoltaic devices are disclosed. The metal inks are selectively deposited on semiconductor coatings by inkjet and aerosol apparatus. The composite is heated to selective temperatures where the metal inks burn through the coating to form an electrical contact with the semiconductor. Metal layers are then deposited on the electrical contacts by light induced or light assisted plating.

  14. A new chromogenic agar medium, chromID VRE, to screen for vancomycin-resistant Enterococcus faecium and Enterococcus faecalis.

    PubMed

    Ledeboer, Nathan A; Tibbetts, Robert J; Dunne, William M

    2007-12-01

    We compared the performance of a chromogenic agar medium chromID VRE (bioMérieux, Marcy-l'Etoile, France) designed to recover and identify vancomycin-resistant enterococci (VRE) from clinical specimens with bile esculin azide vancomycin (BEAV) agar. For this study, 120 stool specimens were plated on chromID VRE and BEAV and examined after 24 and 48 h. At 24 h, the sensitivity and specificity were as follows: BEAV, 90.2% and 73%, respectively; chromID VRE, 86.3% and 100.0%, respectively. Furthermore, we determined that the sensitivity and specificity of chromID VRE for Enterococcus faecium were 85.4% and 100%, respectively, and for Enterococcus faecalis, 90% and 100%, respectively. We conclude that chromID VRE provides an equivalent sensitivity for the recovery of VRE from stool specimens, with improved specificity, and the added advantage of providing differentiation between vancomycin-resistant E. faecium and E. faecalis.

  15. Abolition of Swarming of Proteus by p-Nitrophenyl Glycerin: Application to Blood Agar Media

    PubMed Central

    Williams, Fred D.

    1973-01-01

    Comparative plate counts were made of Staphylococcus aureus and Streptococcus pyogenes growing on blood agar supplemented with individual chemicals to abolish the swarming of Proteus. B-phenylethanol, sodium azide, and p-nitrophenyl glycerin (PNPG) were used as anti-swarm agents. Each anti-swarm agent effectively abolished swarming for 24 h, but azide failed to control swarming for longer periods of incubation. In addition, azide displayed growth inhibition towards the staphylococci and streptococci resulting in no hemolysis and reduced viable cell numbers with the streptococci. Phenylethanol showed reduced viable cell numbers with the streptococci and unreliable hemolytic reactions. At 0.1 to 0.3 mM, PNPG proved to be a superior anti-swarm agent in that it showed no growth inhibition and allowed normal hemolysis, but abolished swarming for extended periods of time. When laboratory strains of Streptococcus pneumoniae, Klebsiella pneumoniae, Pseudomonas aeruginosa. Listeria monocytogenes, and Vibrio cholerae were screened on a blood agar medium containing 0.1 mm PNPG, they displayed similar growth and hemolytic characteristics to the identical medium without PNPG. PMID:4715553

  16. Inoculation of culture plates: straightforward or is it?

    PubMed

    Carlin, E M; Hammond, J A; Boag, F C

    1997-04-01

    In view of the recent vogue in some genitourinary medicine (GUM) units towards selective microscopy we aimed to assess the adequacy of culture plate inoculation in our own GUM clinic by the visual examination of 350 consecutively inoculated plates. Seventy-five (21%) plates were inoculated so lightly that no indentation in the agar could be seen whilst in 20 (60%) the agar was shredded. Eighty-five per cent of inadequately plated samples were inoculated by the same staff members who were either relatively inexperienced, or well-distanced from their last in-service training. This has many important implications not only in the identification and control of infection but also with respect to staff training. We have now introduced practical plating instruction for all new members of clinical staff and additional in-service training. We plan to repeat the audit in 6 months' time to assess the effect of these changes.

  17. Agar disk diffusion (Bauer-Kirby) tests with various fastidious and nonfastidious reference (ATCC) strains: comparison of several agar media.

    PubMed

    Traub, W H; Leonhard, B

    1994-01-01

    Several agar media (Mueller-Hinton agar, MHA; diagnostic sensitivity test agar, DSTA; Schaedler agar, SchA; Todd-Hewitt agar with added yeast extract, THYA; Wilkins-Chalgren agar, WCA) were compared using the Bauer-Kirby agar disk diffusion test against six nonfastidious quality control strains: Staphylococcus aureus ATCC 25923 and ATCC 29213, Escherichia coli ATCC 25922 and ATCC 35218, Pseudomonas aeruginosa ATCC 27853, and Enterococcus faecalis ATCC 29212. MHA, DSTA, and THYA yielded essentially comparable inhibition zones. However, WCA and SchA antagonized cotrimoxazole and aminoglycoside antibiotics; furthermore, SchA antagonized polymyxin B, and both WCA and SchA antagonized imipenem against the P. aeruginosa strain, but not against the E. coli strains. Sheep blood-MHA (Bl-MHA), WCA, THYA, and DSTA were examined with Streptococcus pyogenes ATCC 19615, Streptococcus agalactiae ATCC 13813, and Streptococcus pneumoniae ATCC 6306. In comparison with Bl-MHA, both WCA and THYA yielded comparable inhibition zones against S. pyogenes; DSTA afforded suboptimal growth. DSTA yielded larger inhibition zones with the majority of antimicrobial drugs against S. agalactiae, whereas WCA and THYA enhanced the activity of oxacillin and penicillin G against this strain. S. pneumoniae strain ATCC 6306 grew well on Bl-MHA, yielded suboptimal growth on WCA and faint growth on THYA, and failed to grow on DSTA. Chocolate-supplemented sheep blood-MHA (CHOC-MHA) was compared with Haemophilus test medium (HTM), WCA with added NAD, and THYA with added hematin and NAD against Haemophilus influenzae strains ATCC 35056 and ATCC 49247. The activities of doxycycline and rifampin were enhanced against both strains by HTM, WCA+NAD, and THYA+hematin+NAD. Only WCA+NAD antagonized cotrimoxazole against both H. influenzae strains, an effect due to thymidine; however, HTM antagonized cotrimoxazole against S. aureus ATCC 25923 and E. coli ATCC 25922. It was concluded that Bl-MHA performed best for

  18. Improving agar electrospinnability with choline-based deep eutectic solvents

    Technology Transfer Automated Retrieval System (TEKTRAN)

    One percent agar (% wt) was dissolved in the deep eutectic solvent (DES), (2-hydroxyethyl) trimethylammonium chloride/urea at a 1:2 molar ratio, and successfully electrospun into nanofibers. An existing electrospinning set-up, operated at 50 deg C, was adapted for use with an ethanol bath to collect...

  19. An improved agar medium for growth of Geobacillus thermoglucosidarius strains.

    PubMed

    Javed, M; Baghaei-Yazdi, N; Qin, W; Amartey, S

    2017-01-01

    Geobacillus species have potential applications in many biotechnological processes. They are fastidious in their vitamin and amino acid requirements. A new semi-defined agar medium (SDM) was developed which gave consistently high viable cell counts of various G. thermoglucosidasius strains (5×10(8)-6×10(8)cfu/ml) under aerobic conditions at 70°C.

  20. [Modification of the lysine-iron agar (author's transl)].

    PubMed

    Wauters, G

    1975-12-01

    The addition of L-phenylalanine to the lysine-iron agar described by Edwards and Fife ]1] allows a more valuable screening of the Proteus group based on its deamination properties. Some minor modifications of the indicator and thiosulfate content lead to improve and earlier recording of the results.

  1. Acanthamoeba keratitis presenting as dendritic keratitis in a soft contact lens wearer.

    PubMed

    Yeung, Edward Yip; Huang, Samuel Chao-Ming; Tsai, Ray Jui-Fang

    2002-03-01

    Acanthamoeba keratitis is a rare cause of corneal infection in Taiwan, which can result in devastating visual outcomes. A 37-year-old woman, who wore soft contact lenses, suffered from severe pain in her left eye. Biomicroscopy revealed dendritic keratitis, radial keratoneuritis, and fine keratic precipitates on her cornea. Culture, using non-nutrient agar plate seeded with Escherichia coli, resulted in heavy growth of Acanthamoeba. The inpatient treatment, including topical neomycin-polymyxin B and metronidazole (0.5%) eyedrops, oral ketoconazole, and then oral prednisolone, successfully controlled the corneal infection. The best-corrected visual acuity was 0.9 without any evidence of recurrence of infection after 21 months of follow up. Acanthamoeba keratitis can present as dendritic keratitis, which mimics herpes simplex infection, thus, delays appropriate treatment. Early diagnosis and judicious treatment are essential for restoring the vision and avoiding the subsequent need of penetrating keratoplasty.

  2. A 6 x 6 drop plate method for simultaneous colony counting and MPN enumeration of Campylobacter jejuni, Listeria monocytogenes, and Escherichia coli.

    PubMed

    Chen, Chin Yi; Nace, Gary W; Irwin, Peter L

    2003-11-01

    A protocol was developed using 96-well plates and multichannel pipettes for serial dilutions, followed by drop plating on agar in a 6 x 6 format. This protocol permits simultaneous plating of six dilutions which greatly decreases the number of plates utilized thereby saving incubator space for organisms such as Campylobacter which require unique environmental conditions.

  3. Thermal-induced ageing of agar solutions: impact on the structural and mechanical properties of agar gels

    NASA Astrophysics Data System (ADS)

    Mao, Bosi; Bentaleb, Ahmed; Louerat, Frédéric; Divoux, Thibaut; Snabre, Patrick

    Numerous hydrogels are prepared by cooling down to ambient temperature, aqueous polymer solutions brought to a boil. Although the incubation time of the polymer solution at such a high temperature could be used as a tuning parameter, its impact on the subsequent gelation has been poorly investigated. Here we study the effect of prolonged heating at 80°C on a 1.5% wt solution of agar, a natural polysaccharide. The incubation time is varied from a few hours up to five days. We show that the agar sol. continuously degrades as the result of both the hydrolysis and the intermolecular oxidation of the polymer chains. Furthermore, electronic microscopy and X-ray diffraction experiments reveal that gels formed from older agar sols display an increasingly coarser microstructure composed of micron-sized aggregated pieces of polysaccharides, in contrast with the fibrous-like structure of gels made from fresh sols. Along with structural changes prolonged incubation time leads to weaker gels of lower shear elastic modulus. Finally, macro-indentation experiments coupled to direct visualization show that increasing the incubation time of the agar sol. decreases the yield strain of the gel by a factor of three, while the rupture scenario turns continuously from brittle to ductile-like. Acknowledging funding from BioMérieux & CNRS.

  4. Contact Dermatitis

    MedlinePlus

    ... Us Media contacts Advertising contacts AAD logo Advertising, marketing and sponsorships Legal notice Copyright © 2017 American Academy ... prohibited without prior written permission. AAD logo Advertising, marketing and sponsorships Legal notice Copyright © 2017 American Academy ...

  5. A comparison of antibiotic disks from different sources on Quicolor and Mueller-Hinton agar media in evaluation of antibacterial susceptibility testing

    PubMed Central

    Saffari, Neda; Salmanzadeh-Ahrabi, Siavosh; Abdi-Ali, Ahya; Rezaei-Hemami, Mohsen

    2016-01-01

    Background and Objectives: Antibacterial susceptibility testing of clinical bacterial isolates through disk diffusion method plays a major role in antibacterial treatment. One of the main factors affecting the result of these tests is the type, structure and quality of the disks. The main objective of this study was to compare the agreement of antibiotic disks originated from three companies on Quicolor and Mueller-Hinton agar. Materials and Methods: Quicolor and Mueller-Hinton agar media were used in disk diffusion method. Seventy clinical isolates from Enterobacteriaceae family (21 Klebsiella spp., 36 Escherichia coli, 1 Enterobacter spp. and 12 Shigella spp.) were investigated in the study. After obtaining data, the results were interpreted as resistant, sensitive or intermediate. Kappa coefficient measured the agreement of two media. Coefficient of variation (CV) was also calculated for antibiotic disks. Results: The kappa agreement values for three types of antibiotic disks on Quicolor and Mueller-Hinton agar plates were good or excellent for all the examined antibiotics. CV values were also very satisfactory in the majority of cases. Conclusion: Antibiotic disks from three manufacturers can successfully be used on both Quicolor and Mueller-Hinton agar plates. PMID:28149489

  6. Comparison of dosimetry gels prepared by agar and bovine gelatine

    NASA Astrophysics Data System (ADS)

    Sağsöz, M. E.; Korkut, Ö.; Alemdar, N.; Aktaş, S.; Çalı, E. B.; Kantarcı, M.

    2016-04-01

    Gel dosimeters are unique materials capable of showing three dimensional (3D) dose distributions of therapeutic or diagnostic exposures. Fricke gel dosimeters can be considered as chemical dosimeters that rely on a radiation-induced chemical reaction. Dose distribution of Fricke solutions containing Fe+2 ions determines the transformation of acidic, oxygen saturated Fe+2 ions to Fe+3 ions by the ionizing radiation in aqueous solutions. In this study we produced two different types of gel dosimeters using agar and bovine gelatin with similar fabrication methods. We compared the magnetic resonance (MR) T1 imaging responses of these two gel dosimeters to acquire a dose dependency of MR intensities. In conclusion agar gel dosimeters found to be produced easily and more consistent.

  7. Phenotypic identification of Candida albicans by growth on chocolate agar.

    PubMed

    Sheth, Chirag C; Johnson, Elizabeth; Baker, Mark E; Haynes, Ken; Mühlschlegel, Fritz A

    2005-12-01

    In this study, we describe a simple method for the identification of Candida albicans in clinical samples. A total of 383 clinical isolates of Candida species were streaked onto chocolate agar and incubated for 48 h at 37 degrees C in the presence of an atmosphere of 6% CO2. All 208 of the C. albicans isolates tested, developed an easy to identify filamentous colony morphology. Of 175 other Candida species tested, 172 (98.3%) were distinguishable from C. albicans by their smooth colony morphology. Three isolates (1.7%) exhibited weak filamentation after prolonged incubation. Although not a routine medium in medical mycology a significant advantage of using chocolate agar lies in its use in clinical bacteriology laboratories for the isolation of fastidious bacteria. Implementation of the proposed method is applicable across a range of specimen types, thus allowing the direct identification of C. albicans in clinical samples. This simple method may allow a quicker entry into directed treatment.

  8. Agar-degrading bacteria isolated from Antarctic macroalgae.

    PubMed

    Alvarado, Roxana; Leiva, Sergio

    2017-03-10

    This study describes the taxonomic diversity of pigmented, agar-degrading bacteria isolated from the surface of macroalgae collected in King George Island, Antarctica. A total of 30 pigmented, agarolytic bacteria were isolated from the surface of the Antarctic macroalgae Adenocystis utricularis, Monostroma hariotii, Iridaea cordata, and Pantoneura plocamioides. Based on the 16S rRNA data, the agarolytic isolates were affiliated to the genera Algibacter, Arthrobacter, Brachybacterium, Cellulophaga, Citricoccus, Labedella, Microbacterium, Micrococcus, Salinibacterium, Sanguibacter, and Zobellia. Isolates phylogenetically related to Cellulophaga algicola showed the highest agarase activity in culture supernatants when tested at 4 and 37 °C. This is the first investigation of pigmented agar-degrading bacteria, members of microbial communities associated with Antarctic macroalgae, and the results suggest that they represent a potential source of cold-adapted agarases of possible biotechnological interest.

  9. Mechanical touch responses of Arabidopsis TCH1-3 mutant roots on inclined hard-agar surface

    NASA Astrophysics Data System (ADS)

    Zha, Guodong; Wang, Bochu; Liu, Junyu; Yan, Jie; Zhu, Liqing; Yang, Xingyan

    2016-01-01

    The gravity-induced mechanical touch stimulus can affect plant root architecture. Mechanical touch responses of plant roots are an important aspect of plant root growth and development. Previous studies have reported that Arabidopsis TCH1-3 genes are involved in mechano-related events, how-ever, the physiological functions of TCH1-3 genes in Arabidopsis root mechanoresponses remain unclear. In the present study, we applied an inclined hard agar plate method to produce mechanical touch stimulus, and provided evidence that altered mechanical environment could influence root growth. Furthermore, tch1-3 Arabidopsis mutants were investigated on inclined agar surfaces to explore the functions of TCH1-3 genes on Arabidopsis root mechanoresponses. The results showed that two tch2 mutants, cml24-2 and cml24-4, exhibited significantly reduced root length, biased skewing, and decreased density of lateral root. In addition, primary root length and density of lateral root of tch3 (cml12-2) was significantly decreased on inclined agar surfaces. This study indicates that the tch2 and tch3 mutants are hypersensitive to mechanical touch stimulus, and TCH2 (CML24-2 and CML24-4) and TCH3 (CML12-2) genes may participate in the mechanical touch response of Arabidopsis roots.

  10. Beyond Agar: Gel Substrates with Improved Optical Clarity and Drug Efficiency and Reduced Autofluorescence for Microbial Growth Experiments

    PubMed Central

    McElfresh, Cameron; Wong, Lily R.

    2015-01-01

    Agar, a seaweed extract, has been the standard support matrix for microbial experiments for over a century. Recent developments in high-throughput genetic screens have created a need to reevaluate the suitability of agar for use as colony support, as modern robotic printing systems now routinely spot thousands of colonies within the area of a single microtiter plate. Identifying optimal biophysical, biochemical, and biological properties of the gel support matrix in these extreme experimental conditions is instrumental to achieving the best possible reproducibility and sensitivity. Here we systematically evaluate a range of gelling agents by using the yeast Saccharomyces cerevisiae as a model microbe. We find that carrageenan and Phytagel have superior optical clarity and reduced autofluorescence, crucial for high-resolution imaging and fluorescent reporter screens. Nutrient choice and use of refined Noble agar or pure agarose reduce the effective dose of numerous selective drugs by >50%, potentially enabling large cost savings in genetic screens. Using thousands of mutant yeast strains to compare colony growth between substrates, we found no evidence of significant growth or nutrient biases between gel substrates, indicating that researchers could freely pick and choose the optimal gel for their respective application and experimental condition. PMID:26070672

  11. Mupirocin-mucin agar for selective enumeration of Bifidobacterium bifidum.

    PubMed

    Pechar, Radko; Rada, Vojtech; Parafati, Lucia; Musilova, Sarka; Bunesova, Vera; Vlkova, Eva; Killer, Jiri; Mrazek, Jakub; Kmet, Vladimir; Svejstil, Roman

    2014-11-17

    Bifidobacterium bifidum is a bacterial species exclusively found in the human intestinal tract. This species is becoming increasingly popular as a probiotic organism added to lyophilized products. In this study, porcine mucin was used as the sole carbon source for the selective enumeration of B. bifidum in probiotic food additives. Thirty-six bifidobacterial strains were cultivated in broth with mucin. Only 13 strains of B. bifidum utilized the mucin to produce acids. B. bifidum was selectively enumerated in eight probiotic food supplements using agar (MM agar) containing mupirocin (100 mg/L) and mucin (20 g/L) as the sole carbon source. MM agar was fully selective if the B. bifidum species was presented together with Bifidobacterium animalis subsp. lactis, Bifidobacterium breve, and Bifidobacterium longum subsp. longum species and with lactic acid bacteria (lactobacilli, streptococci). Isolated strains of B. bifidum were identified using biochemical, PCR, MALDI-TOF procedures and 16S rRNA gene sequencing. The novel selective medium was also suitable for the isolation of B. bifidum strains from human fecal samples.

  12. Modeling development of inhibition zones in an agar diffusion bioassay.

    PubMed

    Chandrasekar, Vaishnavi; Knabel, Stephen J; Anantheswaran, Ramaswamy C

    2015-09-01

    A two-temperature agar diffusion bioassay is commonly used to quantify the concentration of nisin using Micrococcus luteus as the indicator microorganism. A finite element computational model based on Fick's second law of diffusion was used to predict the radius of the inhibition zone in this diffusion bioassay. The model developed was used to calculate nisin concentration profiles as a function of time and position within the agar. The minimum inhibitory concentration (MIC) of nisin against M. luteus was determined experimentally. The critical time (T c) for growth of M. luteus within the agar diffusion bioassay was experimentally determined using incubation studies with nisin. The radius of the inhibition zone was predicted from the computational model as the location where the predicted nisin concentration at T c was equal to MIC. The MIC was experimentally determined to be 0.156 μg mL(-1), and T c was determined to be 7 h. Good agreement (R (2) = 0.984) was obtained between model-predicted and experimentally determined inhibition zone radii.

  13. Telocyte's contacts.

    PubMed

    Faussone-Pellegrini, Maria-Simonetta; Gherghiceanu, Mihaela

    2016-07-01

    Telocytes (TC) are an interstitial cell type located in the connective tissue of many organs of humans and laboratory mammals. By means of homocellular contacts, TC build a scaffold whose meshes integrity and continuity are guaranteed by those contacts having a mechanical function; those contacts acting as sites of intercellular communication allow exchanging information and spreading signals. Heterocellular contacts between TC and a great variety of cell types give origin to mixed networks. TC, by means of all these types of contacts, their interaction with the extracellular matrix and their vicinity to nerve endings, are part of an integrated system playing tissue/organ-specific roles.

  14. Direct identification and recognition of yeast species from clinical material by using albicans ID and CHROMagar Candida plates.

    PubMed Central

    Baumgartner, C; Freydiere, A M; Gille, Y

    1996-01-01

    Two chromogenic media, Albicans ID and CHROMagar Candida agar plates, were compared with a reference medium, Sabouraud-chloramphenicol agar, and standard methods for the identification of yeast species. This study involved 951 clinical specimens. The detection rates for the two chromogenic media for polymicrobial specimens were 20% higher than that for the Sabouraud-chloramphenicol agar plates. The rates of identification of Candida albicans for Albicans ID and CHROMagar Candida agar plates were, respectively, 37.0 and 6.0% after 24 h of incubation and 93.6 and 92.2% after 72 h of incubation, with specificities of 99.8 and 100%. Furthermore, CHROMagar Candida plates identified 13 of 14 Candida tropicalis and 9 of 12 Candida krusei strains after 48 h of incubation. PMID:8789038

  15. A selective chromogenic agar that distinguishes Bacillus anthracis from Bacillus cereus and Bacillus thuringiensis.

    PubMed

    Juergensmeyer, Margaret A; Gingras, Bruce A; Restaino, Lawrence; Frampton, Elon W

    2006-08-01

    A selective and differential plating medium, R & F anthracis chromogenic agar (ACA), has been developed for isolating and identifying presumptive colonies of Bacillus anthracis. ACA contains the chromogenic substrate 5-bromo-4-chloro-3-indoxyl-choline phosphate that upon hydrolysis yields teal (blue green) colonies indicating the presence of phosphatidylcholine-specific phospholipase C (PC-PLC) activity. Among seven Bacillus species tested on ACA, only members of the Bacillus cereus group (B. anthracis, B. cereus, and B. thuringiensis) produced teal colonies (PC-PLC positive) having cream rings. Examination of colony morphology in 18 pure culture strains of B. anthracis (15 ATCC strains plus AMES-1-RIID, ANR-1, and AMED-RIID), with one exception, required 48 h at 35 to 37 degrees C for significant color production, whereas only 24 h was required for B. cereus and B. thuringiensis. This differential rate of PC-PLC synthesis in B. anthracis (due to the truncated plcR gene and PlcR regulator in B. anthracis) allowed for the rapid differentiation on ACA of presumptive colonies of B. anthracis from B. cereus and B. thuringiensis in both pure and mixed cultures. Effective recovery of B. anthracis from a variety of matrices having both high (soil and sewage) and low microbial backgrounds (cloth, paper, and blood) spiked with B. anthracis ANR-1 spores suggests the probable utility of ACA plating for B. anthracis recovery in a diversity of applications.

  16. Comparison of CHROMagar Salmonella Medium and Hektoen Enteric Agar for Isolation of Salmonellae from Stool Samples

    PubMed Central

    Gaillot, Olivier; Di Camillo, Patrick; Berche, Patrick; Courcol, René; Savage, Colette

    1999-01-01

    CHROMagar Salmonella (CAS), a new chromogenic medium, was retrospectively compared to Hektoen enteric agar (HEA) with 501 Salmonella stock isolates and was then prospectively compared to HEA for the detection and presumptive identification of Salmonella spp. with 508 stool samples before and after enrichment. All stock cultures (100%), including cultures of H2S-negative isolates, yielded typical mauve colonies on CAS, while 497 (99%) isolates produced typical lactose-negative, black-centered colonies on HEA. Following overnight incubation at 37°C, a total of 20 Salmonella strains were isolated from the 508 clinical samples. Sensitivities for primary plating and after enrichment were 95% (19 isolates) and 100% (20 isolates), respectively, for CAS and 80% (16 isolates) and 100% (20 isolates), respectively, for HEA. The specificity of CAS (88.9%) was significantly higher than that of HEA (78.5%; P < 0.0001). On the basis of its good sensitivity and specificity, CAS medium can be recommended for use for primary plating when human stool samples are screened for Salmonella spp. PMID:9986847

  17. Evaluating survival of Escherichia coli O157:H7 in frozen and thawed apple cider: potential use of a hydrophobic grid membrane filter-SD-39 agar method.

    PubMed

    Sage, J R; Ingham, S C

    1998-04-01

    To determine the susceptibility of Escherichia coli O157:H7 to freezing and thawing in apple cider, methods that recover injured cells are needed for accurate enumeration. This study compared the ISO-GRID hydrophobic grid membrane filter (HGMF) SD-39 agar method to two other methods: a reference most probable number (MPN) method, and plating on sorbitol MacConkey agar (SMA). To determine numbers of injured cells, SMA spread plating was also compared to Trypticase soy agar (TSA) spread plating. Two strains of E. coli O157:H7 QA 326 and ATCC 43895, were inoculated into presterilized apple cider (10 ml) which was then frozen (-20 degrees C for 24 h). Samples were thawed at 4 degrees C for 4 h, or at 23 degrees C for 1.5 h, or in a microwave oven (700 W for 10 s). Substantial cell death (0.69- to 6.33 log10 CFU/ml decreases) and injury (0.70- to 2.38-log10 CFU/ml decreases) occurred during freezing and thawing. The extent of death and injury varied with strain and thawing method. The TSA spread plating method recovered the most cells while the HGMF method always recovered more viable cells than the reference MPN method and also either recovered significantly more (P < 0.05) cells or a not significantly different number of cells than SMA spread plating. Some injured cells of both strains were not counted by the HGMF method. Significant numbers of cells injured by freezing and thawing at 4 degrees C in apple cider were enumerated in the cider was diluted 1:2 Trypticase soy broth immediately before plating. Two epifluorescent microscopic methods showed that injury was not associated with loss of cell membrane integrity.

  18. Peen plating

    NASA Technical Reports Server (NTRS)

    Babecki, A. J. (Inventor); Haehner, C. L.

    1973-01-01

    A process for metal plating which comprises spraying a mixture of metallic powder and small peening particles at high velocity against a surface is described. The velocity must be sufficient to impact and bond metallic powder onto the surface. In the case of metal surfaces, the process has as one of its advantages providing mechanical working (hardening) of the surface simultaneously with the metal plating.

  19. Combined Use of Pastorex Staph-Plus and Either of Two New Chromogenic Agars, MRSA ID and CHROMagar MRSA, for Detection of Methicillin-Resistant Staphylococcus aureus▿

    PubMed Central

    Compernolle, Veerle; Verschraegen, Gerda; Claeys, Geert

    2007-01-01

    We describe the search toward a fast and reliable strategy to detect and confirm the presence of methicillin-resistant Staphylococcus aureus (MRSA) in screening samples. First, we evaluated the sensitivities and specificities of oxacillin resistance screening agar (ORSA) with enrichment (tryptic soy broth [TSB] and ORSA [TSB-ORSA]) and without enrichment (ORSA), MRSA ID (MRSA_ID) plates, and CHROMagar MRSA (C_MRSA) plates, all of which were inoculated with equal volumes of a suspension made by emulsifying screening swabs. Whereas the sensitivities after 48 h were similar for all media tested (77% for MRSA_ID and ORSA; 73% for C_MRSA and ORSA after enrichment [TSB-ORSA]), the specificities of MRSA_ID (98% after 24 h and 94% after 48 h) and C_MRSA (98% after 24 h and 90% after 48 h) were superior to the specificities of ORSAs (92% after 24 h and 83% after 48 h) and TSB-ORSA (86% after 24 h and 81% after 48 h). Subsequently, the performance of the Pastorex Staph-Plus agglutination test with presumptive MRSA isolates taken directly from chromogenic agars (direct_Pastorex agglutination) was compared to that of the Pastorex Staph-Plus agglutination test with isolates from blood agar subcultures (conventional_Pastorex agglutination). When the direct_Pastorex agglutination test on MRSA_ID plates was combined with Gram staining, the direct_Pastorex agglutination test with samples from MRSA_ID plates was as reliable as the conventional_Pastorex agglutination test with samples from blood agar subcultures from MRSA_ID plates. In contrast, the direct_Pastorex agglutination test with samples from C_MRSA plates gave false-negative results. Finally, we calculated the processing times of the four different strategies, namely, (i) enrichment in TSB supplemented with NaCl, subsequent culture on ORSA, and the conventional_Pastorex agglutination test; (ii) direct inoculation of ORSA combined with conventional_Pastorex agglutination test; (iii) direct inoculation of MRSA_ID plates

  20. Electrospinning of agar/PVA aqueous solutions and its relation with rheological properties

    Technology Transfer Automated Retrieval System (TEKTRAN)

    In this work, we report the successful fabrication of agar-based nanofibers by an electrospinning technique using water as the solvent media. A tubeless spinneret was attached inside the electrospinning chamber, operated at 50 deg C, to avoid agar gelation. Pure agar solution 1% (w/w) showed inadequ...

  1. Development of an eco-friendly agar extraction technique from the red seaweed Gracilaria lemaneiformis.

    PubMed

    Li, Haiyan; Yu, Xingju; Jin, Yan; Zhang, Wei; Liu, Yuanling

    2008-05-01

    The red seaweed, Gracilaria lemaneiformis growing as an aquaculture bioremediator along the coasts of Liaodong Peninsula, China, was investigated for the agar production. An eco-friendly method called agar photobleaching extraction process was developed for the benefit of workers' health and safety of the environment. The native agar (NA), alkali-modified agar (AA), chemical-bleached agar (CA) and photobleached agar (PA), which were extracted using different processes, were evaluated for their physical and chemical properties. The PA showed most desirable performances in terms of gel strength, gelling temperature, sulfate content and 3,6-anhydro-l-galactose content. Among the different processed agars, PA gel strength was 1913 g/cm2, the highest among the different processed agars, which increased 8.6% on the basis of the AA. Further we applied this new technique to extract agars from Gracilaria asiatica, and similar results were obtained with that of G. lemaneiformis. This indicates that the agar photobleaching extraction process is a feasible method for Gracilaria species and has a potential application. During the whole agar photobleaching extraction process the pigment content of G. lemaneiformis declined gradually and the TOC concentration in photobleaching solution increased along with the increase in the irradiation time. The mechanism of agar photobleaching could be elucidated by the photolysis theory.

  2. Choline chloride based ionic liquid analogues as tool for the fabrication of agar films with improved mechanical properties.

    PubMed

    Sousa, Ana M M; Souza, Hiléia K S; Latona, Nicholas; Liu, Cheng-Kung; Gonçalves, Maria P; Liu, LinShu

    2014-10-13

    In the present paper, we test the suitability of ChCl/urea (DES-U) and ChCl/glycerol (DES-G) eutectic mixtures, each one prepared at 1:2 molar ratio, for the production of agar films. A three-step process is proposed: pre-solubilization of polymer in DES followed by compression-molding and subsequent drying. The mechanical properties, water resistance and microstructure of the films were evaluated at different polymer concentrations (i.e. 2-6%, w/w). DES-U showed by far, the best film forming ability. Agreeing with the diffusion and SEM data, films with the best mechanical properties were found at the lowest and highest agar concentrations (tensile strengths of 24.2-42 MPa and elongations of 15.4-38.9%). The water sorption and contact angle studies suggested increased hydrophilicity for the film containing the lowest concentration of agar. The use of choline chloride based ionic liquid analogues as solvent and plasticizer might be a promising tool for the development of new non-aqueous materials based on seaweed polysaccharides.

  3. Contact-spring forming machine for flat conductor cable receptacles

    NASA Technical Reports Server (NTRS)

    Angele, W.; Martineck, H. G.

    1968-01-01

    Machine tool produces beryllium-copper contact springs for FCC /flat conductor cable/ feed-through receptacles. The springs are heat-treated and plated to impart the required electrical contact properties.

  4. Contact-resistance test probes: A concept

    NASA Technical Reports Server (NTRS)

    Brooks, C. H.; Maxwell, J. H.; Mc Dermott, R. J.

    1971-01-01

    Devices are used in inspection of contact resistance in plated connectors after assembly into cables. System permits rapid inspection of connectors when mating connectors or special apparatus are not available, and enables source of excessive resistance to be precisely determined.

  5. Plates for vacuum thermal fusion

    DOEpatents

    Davidson, James C.; Balch, Joseph W.

    2002-01-01

    A process for effectively bonding arbitrary size or shape substrates. The process incorporates vacuum pull down techniques to ensure uniform surface contact during the bonding process. The essence of the process for bonding substrates, such as glass, plastic, or alloys, etc., which have a moderate melting point with a gradual softening point curve, involves the application of an active vacuum source to evacuate interstices between the substrates while at the same time providing a positive force to hold the parts to be bonded in contact. This enables increasing the temperature of the bonding process to ensure that the softening point has been reached and small void areas are filled and come in contact with the opposing substrate. The process is most effective where at least one of the two plates or substrates contain channels or grooves that can be used to apply vacuum between the plates or substrates during the thermal bonding cycle. Also, it is beneficial to provide a vacuum groove or channel near the perimeter of the plates or substrates to ensure bonding of the perimeter of the plates or substrates and reduce the unbonded regions inside the interior region of the plates or substrates.

  6. High speed thin plate fatigue crack monitor

    NASA Technical Reports Server (NTRS)

    Wincheski, Buzz A. (Inventor); Heyman, Joseph S. (Inventor); Namkung, Min (Inventor); Fulton, James P. (Inventor)

    1996-01-01

    A device and method are provided which non-destructively detect crack length and crack geometry in thin metallic plates. A non-contacting vibration apparatus produces resonant vibrations without introducing extraneous noise. Resulting resonant vibration shifts in cracked plates are correlated to known crack length in plates with similar resonant vibration shifts. In addition, acoustic emissions of cracks at resonance frequencies are correlated to acoustic emissions from known crack geometries.

  7. Copper removal by algae Gelidium, agar extraction algal waste and granulated algal waste: kinetics and equilibrium.

    PubMed

    Vilar, Vítor J P; Botelho, Cidália M S; Boaventura, Rui A R

    2008-03-01

    Biosorption of copper ions by an industrial algal waste, from agar extraction industry has been studied in a batch system. This biosorbent was compared with the algae Gelidium itself, which is the raw material for agar extraction, and the industrial waste immobilized with polyacrylonitrile (composite material). The effects of contact time, pH, ionic strength (IS) and temperature on the biosorption process have been studied. Equilibrium data follow both Langmuir and Langmuir-Freundlich models. The parameters of Langmuir equilibrium model were: q(max)=33.0mgg(-1), K(L)=0.015mgl(-1); q(max)=16.7mgg(-1), K(L)=0.028mgl(-1) and q(max)=10.3mgg(-1), K(L)=0.160mgl(-1) respectively for Gelidium, algal waste and composite material at pH=5.3, T=20 degrees C and IS=0.001M. Increasing the pH, the number of deprotonated active sites increases and so the uptake capacity of copper ions. In the case of high ionic strengths, the contribution of the electrostatic component to the overall binding decreases, and so the uptake capacity. The temperature has little influence on the uptake capacity principally for low equilibrium copper concentrations. Changes in standard enthalpy, Gibbs energy and entropy during biosorption were determined. Kinetic data at different solution pH (3, 4 and 5.3) were fitted to pseudo-first-order and pseudo-second-order models. The adsorptive behaviour of biosorbent particles was modelled using a batch reactor mass transfer kinetic model, which successfully predicts Cu(II) concentration profiles.

  8. Hyperspectral imaging for differentiating colonies of non-O157 shiga-toxin producing echerichia coli (STEC) serogroups on spread plates of pure cultures

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Direct plating onto solid agar media has been widely used in microbiology laboratories for presumptive-positive pathogen detection in spite of the fact that it is often subjective, labor intensive and time consuming. Rainbow agar is a selective and chromogenic medium that helps to detect pathogenic ...

  9. Optimisation of a direct plating method for the detection and enumeration of Alicyclobacillus acidoterrestris spores.

    PubMed

    Henczka, Marek; Djas, Małgorzata; Filipek, Katarzyna

    2013-01-01

    A direct plating method for the detection and enumeration of Alicyclobacillus acidoterrestris spores has been optimised. The results of the application of four types of growth media (BAT agar, YSG agar, K agar and SK agar) regarding the recovery and enumeration of A. acidoterrestris spores were compared. The influence of the type of applied growth medium, heat shock conditions, incubation temperature, incubation time, plating technique and the presence of apple juice in the sample on the accuracy of the detection and enumeration of A. acidoterrestris spores was investigated. Among the investigated media, YSG agar was the most sensitive medium, and its application resulted in the highest recovery of A. acidoterrestris spores, while K agar and BAT agar were the least suitable media. The effect of the heat shock time on the recovery of spores was negligible. When there was a low concentration of spores in a sample, the membrane filtration method was superior to the spread plating method. The obtained results show that heat shock carried out at 80°C for 10 min and plating samples in combination with membrane filtration on YSG agar, followed by incubation at 46°C for 3 days provided the optimal conditions for the detection and enumeration of A. acidoterrestris spores. Application of the presented method allows highly efficient, fast and sensitive identification and enumeration of A. acidoterrestris spores in food products. This methodology will be useful for the fruit juice industry for identifying products contaminated with A. acidoterrestris spores, and its practical application may prevent economic losses for manufacturers.

  10. Plating isolation of various catalase-negative microorganisms from soil

    NASA Technical Reports Server (NTRS)

    Labeda, D. P.; Hunt, C. M.; Casida, L. E., Jr.

    1974-01-01

    A unique plating procedure was developed that allows isolation, but not enumeration, of representatives of the catalase-negative soil microflora. The numbers recovered, however, are low as compared to the numbers recovered when the modified dilution-to-extinction isolation procedure is used. The latter procedure provides prolonged inoculation in sealed tubes containing a nutritionally rich broth medium over small submerged agar slants. In contrast, the plating procedure utilizes nutritionally minimal media and the shorter incubations mandated by the inherent problems associated with plating.

  11. Electrostatic measurement system. [for contact-electrifying a dielectric

    NASA Technical Reports Server (NTRS)

    Johnston, J. E. (Inventor)

    1975-01-01

    A system for and method of contact-electrifying a dielectric to determine its electrostatic properties is described. The dielectric is placed in contact with a contact plate means, and connected to a voltage source means to charge the contact plate and to contact-electrify the dielectric. The contact plate means is disconnected from the voltage source and a charge sensor means monitors the rate of decay of the charge on the dielectric. If a conductive path from the contact plate to ground is desired, a lead may be connected between the conductor and ground. Automatic timing and charge monitoring are preferred for maximum accuracy, especially where dielectrics treated with antistatic agents are tested.

  12. Characterization of Leptospiral Chemoreceptors Using a Microscopic Agar Drop Assay.

    PubMed

    Affroze, Samia; Islam, Md Shafiqul; Takabe, Kyosuke; Kudo, Seishi; Nakamura, Shuichi

    2016-08-01

    Bacterial chemotaxis is induced by sensing chemical stimuli via chemoreceptors embedded in the cytoplasmic membrane, enabling the cells to migrate toward nutrients or away from toxins. The chemoreceptors of Escherichia coli and Salmonella spp. have been well studied and are functionally classified on the basis of detectable substrates. The spirochete Leptospira possesses more than ten chemoreceptors and shows attractive or repellent responses against some sugars, amino acids, and fatty acids. However, the roles of these chemoreceptors have not been investigated. In this study, we conducted a chemotaxis assay called microscopic agar drop assay in combination with competition experiments, determining whether two kinds of attractants are recognized by the same type of chemoreceptor in the saprophytic Leptospira strain, Leptospira biflexa. Analyzing the competition effect observed between several pairs of chemicals, we found that L. biflexa senses sugars via chemoreceptors different from those that sense amino acids and fatty acids.

  13. Surface migration of Staphylococcus xylosus on low-agar media.

    PubMed

    Dordet-Frisoni, Emilie; Gaillard-Martinie, Brigitte; Talon, Régine; Leroy, Sabine

    2008-05-01

    Staphylococcus xylosus is a commensal species commonly found on the skin of mammals, but also currently used as starter culture for meat fermentation. Most strains of this species colonize by forming a biofilm on abiotic surfaces. We show here that the majority of S. xylosus strains also exhibit extensive colony spreading on the surface of soft agar media. This phenomenon seemed to be independent of biofilm-forming ability. It occurred in different culture media and was dependent on temperature. Formation of a giant S. xylosus colony did not involve a biosurfactant. Microscopic observation showed that the front of the giant colony comprised a single layer of spacing cells with more packed cells in the median area. Supplementation of the soft media with DNase I increased S. xylosus colony spreading, indicating that extracellular DNA may be involved in limiting the phenomenon. The ability of S. xylosus to spread on semi-solid surfaces may constitute an advantage for surface colonization.

  14. Plate electronics

    NASA Astrophysics Data System (ADS)

    Carlowicz, Michael

    Using a Cray T3D supercomputer and a simple assumption about the physical character of Earth's mantle, a pair of researchers from the University of California at Berkeley have built a computer model that may help explain why the planet's tectonic plates look the way they do.In creating a three-dimensional numerical simulation of convection in the Earth's interior, UC researchers Hans-Peter Bunge and Mark Richards simplified their model to account for just one major physical effect: that the viscosity of the mantle increases with depth. Reviewing some recent—but not yet widely accepted—seismic data, Bunge and Richards assumed for the sake of the model that the viscosity of the mantle increases by a factor of 30 from the lithosphere to the core-mantle boundary. Relying on that assumption, the pair ran the model for nearly three weeks on a supercomputer at Los Alamos National Laboratory and found that the simulation produced an effect similar to what we see on the surface of Earth. The model produced a surface paralleling the actual width of plates and the geometry of the plate boundaries.

  15. Comparison of CHROMagar Salmonella Medium and Xylose-Lysine-Desoxycholate and Salmonella-Shigella Agars for Isolation of Salmonella Strains from Stool Samples

    PubMed Central

    Maddocks, Susan; Olma, Tom; Chen, Sharon

    2002-01-01

    The growth and appearance of 115 stock Salmonella isolates on a new formulation of CHROMagar Salmonella (CAS) medium were compared to those on xylose-lysine-desoxycholate agar (XLD), Salmonella-Shigella agar (SS), and Hektoen enteric agar (HEA) media. CAS medium was then compared prospectively to XLD and SS for the detection and presumptive identification of Salmonella strains in 500 consecutive clinical stool samples. All stock Salmonella isolates produced typical mauve colonies on CAS medium. Nine Salmonella strains were isolated from clinical specimens. The sensitivities for the detection of salmonellae after primary plating on CAS medium and the combination of XLD and SS after enrichment were 100%. The specificity for the detection of salmonellae after primary plating on CAS medium (83%) was significantly (P < 0.0001) higher than that after primary plating on the combination of SS and XLD media (55%) (a 28% difference in rates; 95% confidence interval, 23.0 to 34%). Twenty-nine non-Salmonella organisms produced mauve colonies on CAS medium, including 17 Candida spp. (59%) and 8 Pseudomonas spp. (28%). These were easily excluded as salmonellae by colony morphology, microscopic examination of a wet preparation, or oxidase testing. One biochemically inert Escherichia coli isolate required further identification to differentiate it from Salmonella spp. The use of plating on CAS medium demonstrated high levels of sensitivity and specificity and reduced the time to final identification of Salmonella spp., resulting in substantial cost savings. It can be recommended for use for the primary isolation of Salmonella spp. from stool specimens. Other media (e.g., XLD) are required to detect Shigella spp. concurrently. PMID:12149365

  16. Comparison of polymerase chain reaction methods and plating for analysis of enriched cultures of Listeria monocytogenes when using the ISO11290-1 method.

    PubMed

    Dalmasso, Marion; Bolocan, Andrei Sorin; Hernandez, Marta; Kapetanakou, Anastasia E; Kuchta, Tomáš; Manios, Stavros G; Melero, Beatriz; Minarovičová, Jana; Muhterem, Meryem; Nicolau, Anca Ioana; Rovira, Jordi; Skandamis, Panagiotis N; Stessl, Beatrix; Wagner, Martin; Jordan, Kieran; Rodríguez-Lázaro, David

    2014-03-01

    Analysis for Listeria monocytogenes by ISO11290-1 is time-consuming, entailing two enrichment steps and subsequent plating on agar plates, taking five days without isolate confirmation. The aim of this study was to determine if a polymerase chain reaction (PCR) assay could be used for analysis of the first and second enrichment broths, saving four or two days, respectively. In a comprehensive approach involving six European laboratories, PCR and traditional plating of both enrichment broths from the ISO11290-1 method were compared for the detection of L. monocytogenes in 872 food, raw material and processing environment samples from 13 different dairy and meat food chains. After the first and second enrichments, total DNA was extracted from the enriched cultures and analysed for the presence of L. monocytogenes DNA by PCR. DNA extraction by chaotropic solid-phase extraction (spin column-based silica) combined with real-time PCR (RTi-PCR) was required as it was shown that crude DNA extraction applying sonication lysis and boiling followed by traditional gel-based PCR resulted in fewer positive results than plating. The RTi-PCR results were compared to plating, as defined by the ISO11290-1 method. For first and second enrichments, 90% of the samples gave the same results by RTi-PCR and plating, whatever the RTi-PCR method used. For the samples that gave different results, plating was significantly more accurate for detection of positive samples than RTi-PCR from the first enrichment, but RTi-PCR detected a greater number of positive samples than plating from the second enrichment, regardless of the RTi-PCR method used. RTi-PCR was more accurate for non-food contact surface and food contact surface samples than for food and raw material samples especially from the first enrichment, probably because of sample matrix interference. Even though RTi-PCR analysis of the first enrichment showed less positive results than plating, in outbreak scenarios where a rapid result is

  17. Inaccuracy of the disk diffusion method compared with the agar dilution method for susceptibility testing of Campylobacter spp.

    PubMed

    Lehtopolku, Mirva; Kotilainen, Pirkko; Puukka, Pauli; Nakari, Ulla-Maija; Siitonen, Anja; Eerola, Erkki; Huovinen, Pentti; Hakanen, Antti J

    2012-01-01

    The agar dilution method has been standardized by the CLSI for the susceptibility testing of Campylobacter species, and according to these standards, the disk diffusion method should be used only in screening for macrolide and ciprofloxacin resistance. Nevertheless, the disk diffusion test is currently widely used, since it is easy to perform in clinical microbiology laboratories. In this study, the disk diffusion method was compared to the agar dilution method by analyzing the in vitro activities of seven antimicrobial agents against 174 Campylobacter strains collected in Finland between 2003 and 2008. Recommendations of the CLSI were followed using Mueller-Hinton agar plates with 5% of sheep blood. For each strain, the disk diffusion tests were performed two to four times. Of the 33 erythromycin-resistant strains (MIC, ≥16 μg/ml), 24 (73%) constantly showed a 6-mm erythromycin inhibition zone (i.e., no inhibition), while for seven strains the inhibition zone varied from 6 to 44 mm in repeated measurements. Among the 141 erythromycin-susceptible strains (MIC, <16 μg/ml), erythromycin inhibition zones varied between 6 and 61 mm. Of the 87 ciprofloxacin-resistant strains, 47 (54%) showed 6-mm inhibition zones, while 40 strains showed inhibition zones between 6 and 60 mm. Significant differences between the repetitions were observed in the disk diffusion for all antimicrobial agents and all strains except for the macrolide-resistant strains regarding the macrolides. For 17 (10%) strains, the variation in repeated measurements was substantial. These results show that the disk diffusion method may not be a reliable tool for the susceptibility testing of Campylobacter spp. Further studies are needed to assess whether the disk diffusion test could be improved or whether all susceptibilities of campylobacters should be tested using an MIC-based method.

  18. Comparison of spiral gradient and conventional agar dilution for susceptibility testing of anaerobic bacteria.

    PubMed Central

    Wexler, H M; Molitoris, E; Jashnian, F; Finegold, S M

    1991-01-01

    Antimicrobial susceptibility tests were performed on brucella laked blood agar with 340 isolates and 14 antimicrobial agents by the standard agar dilution technique and the spiral gradient technique in which antibiotic concentrations were established by diffusion from the agar surface. For comparison, spiral gradient MICs were determined by calculating antimicrobial concentrations at growth endpoints and rounding up to the next twofold incremental concentration. The cumulative percentage of strains susceptible at the breakpoint determined from spiral gradient data was within 10%, generally, of the percentage of strains susceptible at the breakpoint determined from agar dilution data. The overall agreement between the two techniques (within one doubling dilution) was 90.6%. The spiral gradient agar dilution technique is a reasonable alternative to the conventional agar dilution technique for susceptibility testing of anaerobic bacteria. Images PMID:1929262

  19. [Detection of TDH-producing Vibrio parahaemolyticus O3:K6 from naturally contaminated shellfish using an immunomagnetic separation method and chromogenic agar medium].

    PubMed

    Hara-Kudo, Y; Sugiyama, K; Nishina, T; Saitoh, A; Nakagawa, H; Ichihara, T; Konuma, H; Hasegawa, J; Kumagai, S

    2001-11-01

    We attempted to isolate TDH-producing Vibrio parahaemolyticus O3:K6 from shellfish. Asari samples were incubated with TSB supplemented with 2% (w/v) NaCl for 6 h, and then the 6-h cultures were incubated with salt polymyxin broth for 18 h. After the two-step enrichment, a 1 ml portion of the culture was treated with magnetic beads coated with K6 antibody for immunoconcentration of V. parahaemolyticus O3:K6. The immunoconcentrated and untreated cultures were plated onto a chromogenic agar and TCBS agar media for isolation of V. parahaemolyticus. TDH-producing V. parahaemolyticus O3:K6 was isolated from 3 out of 66 lots (4.5%) of naturally contaminated Asari. Six of 4,265 colonies suspected as V. parahaemolyticus (0.14%) were TDH-producing V. parahaemolyticus O3:K6.

  20. Algivirga pacifica gen. nov., sp. nov., a novel agar-degrading marine bacterium of the family Flammeovirgaceae isolated from Micronesia.

    PubMed

    Kim, Jennifer Jooyoun; Kim, Ji Hyung; Kwon, Young-Kyung; Kwon, Kae Kyoung; Yang, Sung-Hyun; Jang, Jiyi; Heo, Soo-Jin; Park, Heung-Sik; Jung, Won-Kyo; Lee, Youngdeuk; Kang, Do-Hyung; Oh, Chulhong

    2013-12-01

    An aerobic, Gram-negative, coccoid to short rod-shaped and non-flagellated marine bacterial strain S354(T) was isolated from seawater of Micronesia. The strain was capable to degrade agar-forming slight depression into agar plate. Growth occurred at a temperature range of 12-44 °C, a pH range of 5-9, and a salinity range of 1-7 % (w/v) NaCl. Phylogenetic analyses based on 16S rRNA gene sequences suggested that S354(T) belongs to the family Flammeovirgaceae. The novel strain was most closely related to Limibacter armeniacum YM 11-185(T) with similarity of 92.5 %. The DNA G+C content was 43.8 mol%. The major fatty acids (>10 %) were iso-C15:0 and C16:1 ω5c. The predominant isoprenoid quinone was determined to be MK-7. Polar lipid profile of S354(T) consisted of phosphatidylethanolamine, unknown polar lipid, and unknown glycolipids. Based on the phenotypic, phylogenetic, biochemical, and physiological tests conducted in this study, S354(T) is proposed to represent a type strain of a novel genus and species. The 16S rRNA gene sequence of S354(T) is registered in GenBank under the accession number JQ639084. The type of strain Algivirga pacifica gen. nov., sp. nov. is S354(T) (=KCCM 90107(T)=JCM 18326(T)).

  1. Biochemical differentiation of the Enterobacteriaceae with the aid of lysine-iron-agar.

    PubMed

    Johnson, J G; Kunz, L J; Barron, W; Ewing, W H

    1966-03-01

    A procedure is described for identifying members of the family Enterobacteriaceae isolated from clinical specimens. The methods are based on primary differentiation of the various groups of bacteria by the use of Kligler Iron Agar and lysine-iron-agar. For identification of Salmonella, Shigella, and Arizona group organisms from stools, Triple Sugar Iron Agar and lysine-iron-agar are employed. The usefulness of this schema for diagnostic bacteriology laboratories is discussed. It is not intended to replace methods used in reference or research laboratories.

  2. Application of in vitro soft agar techniques for growth of tumor cells to the study of colon cancer.

    PubMed

    Buick, R N; Fry, S E; Salmon, S E

    1980-03-15

    An in vitro assay to measure the clonogenic or colony-forming capability of cancer cells present in biopsy samples has recently been applied to study the biology and drug-sensitivity of a variety of human neoplasms. This approach appears to be suitable for study of the tumor stem or progenitor cells present in malignant effusions from patients with colonic carcinoma. In our preliminary studies, morphology of the tumor colonies by inverted microscopy and with Papanicolaou staining of dried agar plating layers as well as immunofluorescent localization with a specific antiserum to human carcinoembrionic antigen have been used as markers of the neoplastic origin of colon tumor colony-forming cells. Successful application of this assay to colonic solid tumors will require improvement in techniques for disaggregation of viable clonogenic cells. We anticipate that short term clonal assays will have increasing use for clinical and biological studies of human colon cancer.

  3. Effect of seaweed on mechanical, thermal, and biodegradation properties of thermoplastic sugar palm starch/agar composites.

    PubMed

    Jumaidin, Ridhwan; Sapuan, Salit M; Jawaid, Mohammad; Ishak, Mohamad R; Sahari, Japar

    2017-06-01

    The aim of this paper is to investigate the characteristics of thermoplastic sugar palm starch/agar (TPSA) blend containing Eucheuma cottonii seaweed waste as biofiller. The composites were prepared by melt-mixing and hot pressing at 140°C for 10min. The TPSA/seaweed composites were characterized for their mechanical, thermal and biodegradation properties. Incorporation of seaweed from 0 to 40wt.% has significantly improved the tensile, flexural, and impact properties of the TPSA/seaweed composites. Scanning electron micrograph of the tensile fracture showed homogeneous surface with formation of cleavage plane. It is also evident from TGA results that thermal stability of the composites were enhanced with addition of seaweed. After soil burial for 2 and 4 weeks, the biodegradation of the composites was enhanced with addition of seaweed. Overall, the incorporation of seaweed into TPSA enhances the properties of TPSA for short-life product application such as tray, plate, etc.

  4. Comparison of isolation of Haemophilus vaginalis (Corynebacterium vaginale) from peptone-starch-dextrose agar and Columbia colistin-nalidoxic acid agar.

    PubMed Central

    Golberg, R L; Washington JA, I I

    1976-01-01

    A total of 447 cervical or vaginal specimens were inoculated in parallel onto peptone-starch-dextrose (PSD) and Columbia colistin (10 mg/ml)-nalidixic acid (15 mug/ml) (CNA) agar and were incubated for 48 h at 35 degrees C in an atmosphere with 2 to 10% CO2. One hundred (22.4%) of the cultures were positive for Haemophilus vaginalis. Forty-eight of the isolates were recovered from both PSD and Columbia CNA agar, five from PSD only, and 47 from Columbia CNA agar only (P less than 0.001). On Columbia CNA agar, 76 of the isolates were detected after 24 h of incubation, and the remainder were detected within 4 days of incubation. PMID:1085777

  5. Integrated carbon composite bipolar plate for polymer-electrolyte membrane fuel cells

    NASA Astrophysics Data System (ADS)

    Yu, Ha Na; Hwang, In Uk; Kim, Seong Su; Lee, Dai Gil

    The electrical resistance of bipolar plates for polymer-electrolyte membrane fuel cells (PEMFCs) should be very low to conduct the electricity generated with minimum electrical loss. The resistance of a bipolar plate consists of the bulk material resistance and the interfacial contact resistance when two such plates are contacted to provide channels for fuel and air (oxygen) supplies. Since the interfacial contact resistance is much larger than the bulk resistance in an actual fuel cell stack, an integrated carbon composite bipolar plate is developed in this study to eliminate the contact resistance between contacting bipolar plates. To fabricate this plate with channels for fuel, air and coolant, many stainless-steel pipes of 1 mm diameter are uniformly embedded in the carbon fiber/epoxy composite prepreg and co-cured. The contact resistance, flexural strength and thermal degradation temperatures of the developed composite bipolar plate are then measured.

  6. Contact hysteroscopy.

    PubMed

    Baggish, M S; Barbot, J

    1983-06-01

    In 1907 innovations in optics and illumination made by Maximilian Nitze were applied to hysteroscopy by Charles David, who wrote a treatise of hysteroscopy. David improved illumination by placing an electric incandescent bulb at the intrauterine end of his endoscope and also sealed the distal end of the tube with a piece of glass. The history of the contact endoscope that the authors personally used is connected to the invention by Vulmiere (1952) of a revolutionary illumination process in endoscopy--the "cold light" process. The components of cold light consist of a powerful external light source that is transmitted via a special optical guide into the endometrial cavity. The 1st application of his principle (1963) was an optical trochar contained in a metallic sheath. This simple endoscope was perfected, and in 1973 Barbot and Parent, in France, began to use it to examine the uterine cavity. Discussion focuses on methods, instrumentation, method for examination (grasping the instrument, setup, light source, anesthesia, dilatation, technique, and normal endometrium); cervical neoplasia; nonneoplastic lesions of the endometrium (endometrial polyp, submucous myoma, endometrial hyperplasia); intrauterine device localization; neoplastic lesions of the endometrium; precursors (adenocarcinoma); hysteroscopy in pregnancy (embryoscopy, hydatidiform mole, postpartum hemorrhage, incomplete abortion, spontaneous abortion, induced abortions, and amnioscopy); and examinations of children and infants. The contact endoscope must make light contact with the structure to be viewed. The principles of contact endoscopy depend on an interpretation of color, contour, vascular pattern, and a sense of touch. These are computed together and a diagnosis is made on the basis of previously learned clinical pathologic correlations. The contact endoscope is composed of 3 parts: an optical guide; a cylindric chamber that collects and traps ambient light; and a magnifying eyepiece. The phase of

  7. Biomechanical study of different plate configurations for distal humerus osteosynthesis.

    PubMed

    Bogataj, M; Kosel, F; Norris, R; Krkovic, M; Brojan, M

    2015-05-01

    Fractures of the distal humerus are most commonly fixed by open reduction and internal fixation, using plates and screws, either in a locking or in a non-locking construct. Three different plating systems are commonly used in practice. The most important differences between them are in plate orientation, which affects both the rigidity of the osteosynthesis and invasiveness of the surgical procedure. Unfortunately, there is no common agreement between surgeons about which plate configuration brings the best clinical outcome. In this study, we investigate the theoretical rigidity of plate osteosyntheses considering two types of AO/ASIF configurations (90° angle between plates), Mayo clinic (Acumed) configuration (180° between plates) and dorsal fixation of both plates. We also compared the results for cases with and without contact between the bone fragments. In the case of no bone contact, the Mayo clinic plate configuration is found to be the most rigid, followed by both AO/ASIF plate configurations, and the least rigid system is the Korosec plate configuration. On the other hand, no significant differences between all types of fixation configurations are found in cases with contact in-between the bone fragments. Our findings show that this contact is very important and can compensate for the lack of load carrying capacity of the implants. This could therefore incite other implant fixation solutions, leading to less invasive surgical procedures and consequently improved clinical outcome.

  8. Quenching of the antibacterial activity of chlorhexidine and benzalkonium by Letheen broth and Letheen agar in relation to wild-type and envelope mutant strains of gram-negative bacteria.

    PubMed

    el-Falaha, B M; Furr, J R; Russell, A D

    1987-01-01

    Letheen broth and Letheen agar have been investigated for their ability to act as neutralising and recovery media for wild-type and envelope mutants exposed to chlorhexidine diacetate and benzalkonium chloride. At high dilutions, untreated cells of the envelope mutant of Pseudomonas aeruginosa 799/61 were unable to produce colonies on Letheen agar. As a result of various procedures, it was concluded that dilution in Letheen broth and plating in Isosensitest agar was a suitable method for quenching cationic bactericides without harming the test strains, and that the increasing use of Gram-negative bacteria with outer membrane defects means that considerable care may be necessary in selecting media for evaluating bactericidal activity.

  9. Detection of mycobacteria by radiometric and standard plate procedures.

    PubMed Central

    Damato, J J; Collins, M T; Rothlauf, M V; McClatchy, J K

    1983-01-01

    A group of 89 smear-positive sputum specimens were evaluated by radiometric and standard plate procedures to determine the methodology which would provide the earliest detection of mycobacteria and maximum test sensitivity. Digested non-decontaminated specimens were concentrated and inoculated into modified selective BACTEC radiometric 7H12 broth and Mitchison selective 7H10 agar. Sodium hydroxide (1.5% final concentration) was then used to decontaminate these specimens. They were then concentrated and inoculated into both selective and nonselective 7H12 radiometric broths and into selective 7H10 and nonselective Middlebrook 7H11 agar media. The specimen processing and media combinations providing the earliest detection were non-decontaminated specimens with modified selective 7H12 BACTEC broth and decontaminated specimens with 7H12 BACTEC broths. Maximum sensitivity (percent positive) was obtained by using non-decontaminated specimens on Mitchison selective 7H10 Agar (98%) or decontaminated specimens in 7H12 BACTEC broth (95%). The decontamination process was found to reduce significantly the number of mycobacteria in clinical specimens, particularly the mycobacteria other than Mycobacterium tuberculosis. The specimen processing-media combinations providing the earliest detection and maximum recovery of mycobacteria (100%) were non-decontaminated specimens with modified selective 7H12 BACTEC broth or Mitchison selective agar and decontaminated specimens with 7H12 BACTEC broth or 7H11 agar. PMID:6348076

  10. Electroless metal plating of plastics

    DOEpatents

    Krause, Lawrence J.

    1986-01-01

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  11. Electroless metal plating of plastics

    DOEpatents

    Krause, L.J.

    1982-09-20

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  12. Electroless metal plating of plastics

    DOEpatents

    Krause, Lawrence J.

    1984-01-01

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  13. Evaluation of fluorogenic TSC agar for recovering Clostridium perfringens in groundwater samples.

    PubMed

    Araujo, M; Sueiro, R A; Gómez, M J; Garrido, M J

    2001-01-01

    Clostridium perfringens is widely recognised as a reliable water pollution indicator. Since several media can be employed for the membrane filtration enumeration of this microorganism, the main aim of this work was to investigate the ability of fluorocult-supplemented TSC-agar (Merck) for recovering Cl. perfringens from public springs used for direct human consumption. Cl. perfringens recovery was also performed on mCP agar (Cultimed) according to Directive 98/83 as well as on TSC-Agar (Merck), TSN-Agar (Merck) and SPS-Agar (BBL) media. Variance analysis of data obtained showed no statistically significant differences in the counts obtained among all media employed in this work. However, the Cl. perfringens recovery efficiencies with TSC and fluorogenic TSC agars were significantly greater (P = < 0.05) than the corresponding values of mCP and TSN media. On the other hand, the identification of typical and atypical colonies isolated from all media demonstrated that fluorogenic TSC agar was the most specific medium for Cl. perfringens recovery in groundwater samples (85.3% of typical colonies and 82.8% of atypical colonies confirmed). In summary, the membrane filtration technique with fluorogenic TSC agar showed the best performance characteristics of all the media tested as judged by their recovery efficiency and specificity in these water samples.

  14. Electrospinning of agar/PVA aqueous solutions and its relation with rheological properties.

    PubMed

    Sousa, Ana M M; Souza, Hiléia K S; Uknalis, Joseph; Liu, Shih-Chuan; Gonçalves, Maria P; Liu, LinShu

    2015-01-22

    In this work, we report the successful fabrication of agar-based nanofibers by electrospinning technique, using water as solvent media. A tubeless spinneret was attached inside the electrospinning chamber, operating at 50°C, to avoid agar gelation. Agar pure solution (1 wt%) showed inadequate spinnability regardless of the used electrospinning conditions. The addition of a co-blending polymer such as PVA (10 wt% starting solution) improved the solutions viscoelasticity and hence, the solutions spinnability. Agar/PVA solutions were prepared with different mass ratios (100/0, 50/50, 40/60, 30/70, 20/80 and 0/100) and electrospun at various sets of electrospinning conditions. Best nanofibers were obtained with 30/70 and 20/80 agar/PVA blends while samples with higher agar contents (50/50 and 40/60 agar/PVA) were harder to process and led to discontinuous fibrous mats. This first set of encouraging results can open a new window of opportunities for agar-based biomaterials in the form of nanofibers.

  15. Characteristics of thermoplastic sugar palm Starch/Agar blend: Thermal, tensile, and physical properties.

    PubMed

    Jumaidin, R; Sapuan, S M; Jawaid, M; Ishak, M R; Sahari, J

    2016-08-01

    The aim of this work is to study the behavior of biodegradable sugar palm starch (SPS) based thermoplastic containing agar in the range of 10-40wt%. The thermoplastics were melt-mixed and then hot pressed at 140°C for 10min. SEM investigation showed good miscibility between SPS and agar. FT-IR analysis confirmed that SPS and agar were compatible and inter-molecular hydrogen bonds existed between them. Incorporation of agar increased the thermoplastic starch tensile properties (Young's modulus and tensile strength). The thermal stability and moisture uptake increased with increasing agar content. The present work shows that starch-based thermoplastics with 30wt% agar content have the highest tensile strength. Higher content of agar (40wt%) resulted to more rough cleavage fracture and slight decrease in the tensile strength. In conclusion, the addition of agar improved the thermal and tensile properties of thermoplastic SPS which widened the potential application of this eco-friendly material. The most promising applications for this eco-friendly material are short-life products such as packaging, container, tray, etc.

  16. Adsorptive removal of methylene blue by agar: effects of NaCl and ethanol

    PubMed Central

    2012-01-01

    Adsorption of methylene blue (MB) on agar was investigated as a function of temperature (308-328 K), different concentrations of NaCl and HCl and various weight percentages of binary mixtures of ethanol with water. It was observed that the maximum experimental adsorption capacity, qm, exp, in water is up to 50 mg g-1 and decreases with increase in weight percentage of ethanol and NaCl and HCl concentration compared to that of water. Analysis of data using ARIAN model showed that MB adsorbs as monomer and dimer on the surface of agar. Binding constants of MB to agar were calculated using the Temkin isotherm. The process is exothermic in water and other solutions. The mean adsorption energy (E) value indicated binding of MB to agar is chemical adsorption. Kinetics of this interaction obeys from the pseudo-second-order model and diffusion of the MB molecules into the agar is the main rate-controlling step. PMID:22339759

  17. Dynamic contact angle measurements on superhydrophobic surfaces

    NASA Astrophysics Data System (ADS)

    Kim, Jeong-Hyun; Kavehpour, H. Pirouz; Rothstein, Jonathan P.

    2015-03-01

    In this paper, the dynamic advancing and receding contact angles of a series of aqueous solutions were measured on a number of hydrophobic and superhydrophobic surfaces using a modified Wilhelmy plate technique. Superhydrophobic surfaces are hydrophobic surfaces with micron or nanometer sized surface roughness. These surfaces have very large static advancing contact angles and little static contact angle hysteresis. In this study, the dynamic advancing and dynamic receding contact angles on superhydrophobic surfaces were measured as a function of plate velocity and capillary number. The dynamic contact angles measured on a smooth hydrophobic Teflon surface were found to obey the scaling with capillary number predicted by the Cox-Voinov-Tanner law, θD3 ∝ Ca. The response of the dynamic contact angle on the superhydrophobic surfaces, however, did not follow the same scaling law. The advancing contact angle was found to remain constant at θA = 160∘, independent of capillary number. The dynamic receding contact angle measurements on superhydrophobic surfaces were found to decrease with increasing capillary number; however, the presence of slip on the superhydrophobic surface was found to result in a shift in the onset of dynamic contact angle variation to larger capillary numbers. In addition, a much weaker dependence of the dynamic contact angle on capillary number was observed for some of the superhydrophobic surfaces tested.

  18. Types of Contact Lenses

    MedlinePlus

    ... Consumer Devices Consumer Products Contact Lenses Types of Contact Lenses Share Tweet Linkedin Pin it More sharing ... Orthokeratology (Ortho-K) Decorative (Plano) Contact Lenses Soft Contact Lenses Soft contact lenses are made of soft, ...

  19. Prioritized Contact Transport Stream

    NASA Technical Reports Server (NTRS)

    Hunt, Walter Lee, Jr. (Inventor)

    2015-01-01

    A detection process, contact recognition process, classification process, and identification process are applied to raw sensor data to produce an identified contact record set containing one or more identified contact records. A prioritization process is applied to the identified contact record set to assign a contact priority to each contact record in the identified contact record set. Data are removed from the contact records in the identified contact record set based on the contact priorities assigned to those contact records. A first contact stream is produced from the resulting contact records. The first contact stream is streamed in a contact transport stream. The contact transport stream may include and stream additional contact streams. The contact transport stream may be varied dynamically over time based on parameters such as available bandwidth, contact priority, presence/absence of contacts, system state, and configuration parameters.

  20. Continuous degradation of maltose: improvement in stability and catalytic properties of maltase (α-glucosidase) through immobilization using agar-agar gel as a support.

    PubMed

    Nawaz, Muhammad Asif; Karim, Asad; Aman, Afsheen; Marchetti, Roberta; Qader, Shah Ali Ul; Molinaro, Antonio

    2015-04-01

    Maltose degrading enzyme was immobilized within agar-agar support via entrapment method due to its industrial utilization. The maximum immobilization efficiency (82.77%) was achieved using 4.0% agar-agar keeping the diameter of bead up to 3.0 mm. The matrix entrapment showed maximum catalytic activity at pH 7.0 and temperature 65 °C. Substrate saturation kinetics showed that the K m of immobilized enzyme increased from 1.717 to 2.117 mM ml(-1) where as Vmax decreased from 8,411 to 7,450 U ml(-1 )min(-1) as compared to free enzyme. The immobilization significantly increased the stability of maltase against various temperatures and immobilized maltase retain 100% of its original activity after 2 h at 50 °C, whereas the free maltase only showed 60% residual activity under same condition. The reusability of entrapped maltase showed activity up to 12 cycles and retained 50% of activity even after 5th cycle. Storage stability of agar entrapped maltase retain 73% of its initial activity even after 2 months when stored at 30 °C while free enzyme showed only 37% activity at same storage conditions.

  1. An interlaboratory study on efficient detection of Shiga toxin-producing Escherichia coli O26, O103, O111, O121, O145, and O157 in food using real-time PCR assay and chromogenic agar.

    PubMed

    Hara-Kudo, Yukiko; Konishi, Noriko; Ohtsuka, Kayoko; Iwabuchi, Kaori; Kikuchi, Rie; Isobe, Junko; Yamazaki, Takumiko; Suzuki, Fumie; Nagai, Yuhki; Yamada, Hiroko; Tanouchi, Atsuko; Mori, Tetsuya; Nakagawa, Hiroshi; Ueda, Yasufumi; Terajima, Jun

    2016-08-02

    To establish an efficient detection method for Shiga toxin (Stx)-producing Escherichia coli (STEC) O26, O103, O111, O121, O145, and O157 in food, an interlaboratory study using all the serogroups of detection targets was firstly conducted. We employed a series of tests including enrichment, real-time PCR assays, and concentration by immunomagnetic separation, followed by plating onto selective agar media (IMS-plating methods). This study was particularly focused on the efficiencies of real-time PCR assays in detecting stx and O-antigen genes of the six serogroups and of IMS-plating methods onto selective agar media including chromogenic agar. Ground beef and radish sprouts samples were inoculated with the six STEC serogroups either at 4-6CFU/25g (low levels) or at 22-29CFU/25g (high levels). The sensitivity of stx detection in ground beef at both levels of inoculation with all six STEC serogroups was 100%. The sensitivity of stx detection was also 100% in radish sprouts at high levels of inoculation with all six STEC serogroups, and 66.7%-91.7% at low levels of inoculation. The sensitivity of detection of O-antigen genes was 100% in both ground beef and radish sprouts at high inoculation levels, while at low inoculation levels, it was 95.8%-100% in ground beef and 66.7%-91.7% in radish sprouts. The sensitivity of detection with IMS-plating was either the same or lower than those of the real-time PCR assays targeting stx and O-antigen genes. The relationship between the results of IMS-plating methods and Ct values of real-time PCR assays were firstly analyzed in detail. Ct values in most samples that tested negative in the IMS-plating method were higher than the maximum Ct values in samples that tested positive in the IMS-plating method. This study indicates that all six STEC serogroups in food contaminated with more than 29CFU/25g were detected by real-time PCR assays targeting stx and O-antigen genes and IMS-plating onto selective agar media. Therefore, screening

  2. Corrugated cover plate for flat plate collector

    DOEpatents

    Hollands, K. G. Terry; Sibbitt, Bruce

    1978-01-01

    A flat plate radiant energy collector is providing having a transparent cover. The cover has a V-corrugated shape which reduces the amount of energy reflected by the cover away from the flat plate absorber of the collector.

  3. Universal growth of microdomains and gelation transition in agar hydrogels.

    PubMed

    Boral, Shilpi; Saxena, Anita; Bohidar, H B

    2008-03-27

    Investigations were carried out on aqueous sols and gels of agar (extracted from red seaweed Gelidiella acerosa) to explore the growth of microdomains en route to gelation. Isothermal frequency sweep studies on gel samples revealed master plots showing power-law dependence of gel elastic modulus, |G*|, on oscillation frequency, omega as |G*| approximately omegan, independent of temperature, with 0.5Tg). The S(q,t) behavior close to the gel transition point (Tg approximately (38+/-3 degrees C determined from rheology) followed a stretched exponential function: S(t)=A exp(-t/ts)beta. The beta factor increased from 0.25 to 1 as the gel temperature approached 25 degrees C from Tg, and relaxation time, ts, showed a peak at T approximately 30 degrees C. The SLS data (in the sol state) suggested the scaling of scattered intensity, Is(q) approximately epsilon(-gamma) (epsilon=(T/Tg-1), T>Tg) with gamma=0.13+/-0.03, and the presence of two distinct domains characterized by a Guinier regime (low q) and a power-law regime (high q). Close to and above Tg (+2 degrees C), IS(q) scaled with q as Is(q) approximately q(-alpha) with alpha=2.2+/-0.2, which decreased to 1.4+/-1 just below Tg (-2 degrees C), implying a coil-helix transition for 0.2% (w/v) and 0.3% (w/v) samples. For a 0.01% sample, alpha=3.5+/-0.5 which

  4. Peridinialean dinoflagellate plate patterns, labels and homologies

    USGS Publications Warehouse

    Edwards, L.E.

    1990-01-01

    Tabulation patterns for peridinialean dinoflagellate thecae and cysts have been traditionally expressed using a plate labelling system described by C.A. Kofoid in the early 1900's. This system can obscure dinoflagellate plate homologies and has not always been strictly applied. The plate-labelling system presented here introduces new series labels but incorporates key features and ideas from the more recently proposed systems of G.L. Eaton and F.J.R. Taylor, as modified by W.R. Evitt. Plate-series recognition begins with the cingulum (C-series) and proceeds from the cingulum toward the apex for the three series of the epitheca/epicyst and proceeds from the cingulum toward the antapex for the two series of the hypotheca/hypocyst. The epithecal/epicystal model consists of eight plates that touch the anterior margin of the cingulum (E-series: plates E1-E7, ES), seven plates toward the apex that touch the E-series plates (M-series: R, M1-M6), and up to seven plates near the apex that do not touch E-series plates (D-series: Dp-Dv). The hypothecal/hypocystal model consists of eight plates that touch the posterior margin of the cingulum (H-series: H1-H6,HR,HS) and three plates toward the antapex (T1-T3). Epithecal/epicystal tabulation patterns come in both 8- and 7- models, corresponding to eight and seven plates, respectively, in the E-series. Hypothecal/hypocystal tabulation patterns also come in both 8- and 7-models, corresponding to eight and seven plates, respectively, in the H-series. By convention, the 7-model epitheca/epicyst has no plates E1 and M1; the 7-model hypotheca/hypocyst has no plate H6. Within an 8-model or 7-model, the system emphasizes plates that are presumed to be homologous by giving them identical labels. I introduce the adjectives "monothigmate", "dithigmate," and "trithigmate" to designate plates touching one, two, and three plates, respectively, of the adjacent series. The term "thigmation" applies to the analysis of plate contacts between

  5. Detection of Agar, by Analysis of Sugar Markers, Associated with Bacillus Anthracis Spores, After Culture

    SciTech Connect

    Wunschel, David S.; Colburn, Heather A.; Fox, Alvin; Fox, Karen F.; Harley, William M.; Wahl, Jon H.; Wahl, Karen L.

    2008-08-01

    Detection of small quantities of agar associated with spores of Bacillus anthracis could provide key information regarding its source or growth characteristics. Agar, widely used in growth of bacteria on solid surfaces, consists primarily of repeating polysaccharide units of 3,6-anhydro-L-galactose (AGal) and galactose (Gal) with sulfated and O-methylated galactoses present as minor constituents. Two variants of the alditol acetate procedure were evaluated for detection of potential agar markers associated with spores. The first method employed a reductive hydrolysis step, to stabilize labile anhydrogalactose, by converting to anhydrogalactitol. The second eliminated the reductive hydrolysis step simplifying the procedure. Anhydrogalactitol, derived from agar, was detected using both derivatization methods followed by gas chromatography-mass spectrometry (GC-MS) analysis. However, challenges with artefactual background (reductive hydrolysis) or marker destruction (hydrolysis) lead to the search for alternative sugar markers. A minor agar component, 6-O-methyl galactose (6-O-M gal), was readily detected in agar-grown but not broth-grown bacteria. Detection was optimized by the use of gas chromatography-tandem mass spectrometry (GC-MS-MS). With appropriate choice of sugar marker and analytical procedure, detection of sugar markers for agar has considerable potential in microbial forensics.

  6. Growth Plate Fractures

    MedlinePlus

    .org Growth Plate Fractures Page ( 1 ) The bones of children and adults share many of the same risks for injury. But because they ... to a unique injury called a growth plate fracture. Growth plates are areas of cartilage located near ...

  7. Growth characteristics of Bacillus anthracis compared to other Bacillus spp. on the selective nutrient media Anthrax Blood Agar and Cereus Ident Agar.

    PubMed

    Tomaso, Herbert; Bartling, Carsten; Al Dahouk, Sascha; Hagen, Ralf M; Scholz, Holger C; Beyer, Wolfgang; Neubauer, Heinrich

    2006-01-01

    Anthrax Blood Agar (ABA) and Cereus Ident Agar (CEI) were evaluated as selective growth media for the isolation of Bacillus anthracis using 92 B. anthracis and 132 other Bacillus strains from 30 species. The positive predictive values for the identification of B. anthracis on ABA, CEI, and the combination of both were 72%, 71%, and 90%, respectively. Thus, less than 10% of all species were misidentified using both nutrient media. Species which might be misidentified as B. anthracis were B. cereus, B. mycoides, and B. thuringiensis. Particularly, 30% of B. weihenstephanensis strains were misidentified as B. anthracis.

  8. Preparation and application of agar/alginate/collagen ternary blend functional food packaging films.

    PubMed

    Wang, Long-Feng; Rhim, Jong-Whan

    2015-09-01

    Ternary blend agar/alginate/collagen (A/A/C) hydrogel films with silver nanoparticles (AgNPs) and grapefruit seed extract (GSE) were prepared. Their performance properties, transparency, tensile strength (TS), water vapor permeability (WVP), water contact angle (CA), water swelling ratio (SR), water solubility (WS), and antimicrobial activity were determined. The A/A/C film was highly transparent, and both AgNPs and GSE incorporated blend films (A/A/C(AgNPs) and A/A/C(GSE)) exhibited UV-screening effect, especially, the A/A/C(GSE) film had high UV-screening effect without sacrificing the transmittance. In addition, the A/A/C blend films formed efficient hydrogel film with the water holding capacity of 23.6 times of their weight. Both A/A/C(AgNPs) and A/A/C(GSE) composite films exhibited strong antimicrobial activity against both Gram-positive (Listeria monocytogenes) and Gram-negative (Escherichia coli) food-borne pathogenic bacteria. The test results of fresh potatoes packaging revealed that all the A/A/C ternary blend films prevented forming of condensed water on the packaged film surface, both A/A/C(AgNPs) and A/A/C(GSE) composite films prevented greening of potatoes during storage. The results indicate that the ternary blend hydrogel films incorporated with AgNPs or GSE can be used not only as antifogging packaging films for highly respiring fresh agriculture produce, but also as an active food packaging system utilizing their strong antimicrobial activity.

  9. High effectiveness contour matching contact heat exchanger

    NASA Technical Reports Server (NTRS)

    Blakely, Robert L. (Inventor); Roebelen, George J., Jr. (Inventor); Davenport, Arthur K. (Inventor)

    1988-01-01

    There is a need in the art for a heat exchanger design having a flexible core providing contour matching capabilities, which compensates for manufacturing tolerance and distortion buildups, and which accordingly furnishes a relatively uniform thermal contact conductance between the core and external heat sources under essentially all operating conditions. The core of the heat exchanger comprises a top plate and a bottom plate, each having alternate rows of pins attached. Each of the pins fits into corresponding tight-fitting recesses in the opposite plate.

  10. A simple plate-assay for screening extracellular naringinase produced by streptomycetes.

    PubMed

    Caraveo, Leonela; Medina, Héctor; Rodríguez-Buenfil, Ingrid; Montalvo-Romero, Carlos; Evangelista-Martínez, Zahaed

    2014-07-01

    A simple plate-assay was developed with the purpose of detecting extracellular naringinase in streptomycetes. The naringin agar medium (NAM) was prepared by mixing carbon utilization medium (ISP9) and naringin. The clearing zones around colonies are correlated with the enzymatic activity. The assay validation was performed through the use of commercial naringinase (Penicillium decumbens).

  11. Carriage of Multidrug Resistant Bacteria on Frequently Contacted Surfaces and Hands of Health Care Workers

    PubMed Central

    Visalachy, Sowndarya; Kopula, Sridharan Sathyamoorthy; Sekar, Uma

    2016-01-01

    Introduction Maximal contact between the patients and Health Care Workers (HCWs) happens in the Intensive Care Units (ICU). Control of nosocomial infections requires compliance with hand hygiene and contamination free surfaces. Aim To determine the colonization of potential pathogens in the hands of HCWs and frequent contacted environmental surfaces. Materials and Methods A cross sectional study was conducted between September 2012 and May 2013 at Sri Ramachandra Medical College and Hospital. A total of 327 samples were collected using Glove juice technique from hands and swabs from frequently contacted surfaces. A sum of 157 samples were collected by glove juice technique from the hands of HCWs which included Consultants (20), Internees (3), Residents (10), Staff nurse (102) and support staff (22). A total of 170 samples were collected through swabbing which included frequently touched surfaces of apron and dress (140 which included 10 consultants, 3 internees, 9 Residents, 101 Staff nurse and 17 support staff), 9 door handle, 4 key board, 12 tap handles and 5 monitors. The samples were inoculated into Blood agar, Chocolate agar and Mac-Conkey agar plates and incubated at 370C aerobically. The plates showing growth were further processed to identify the organisms by Gram staining and biochemical reactions. Antibiotic susceptibility testing was done for the isolates by Kirby-baur disc diffusion method as per CLSI guidelines. Results Out of the 157 hand sampling done by glove juice method 67(42.7%) of them showed growth and 90(57.3%) showed no growth. The potential pathogens grown were 13 (8.3%), consisting of Methicillin Sensitive Staphylococcus aureus (MSSA) 6(3.8%), Methicillin Resistant Staphylococcus aureus (MRSA) 2(1.3%), Pseudomonas spp 4(2.6%) and Acenitobacter spp 1 (0.6%). The MRSA was seen in Consultant 1(5%; n=20) and Staff nurse 1(0.9%; n= 102). Among the 140 sampling from the dress of HCWs growth was observed in 69(49.3%) and growth was absent in 71

  12. Longer Contact Times Increase Cross-Contamination of Enterobacter aerogenes from Surfaces to Food.

    PubMed

    Miranda, Robyn C; Schaffner, Donald W

    2016-11-01

    Bacterial cross-contamination from surfaces to food can contribute to foodborne disease. The cross-contamination rate of Enterobacter aerogenes on household surfaces was evaluated by using scenarios that differed by surface type, food type, contact time (<1, 5, 30, and 300 s), and inoculum matrix (tryptic soy broth or peptone buffer). The surfaces used were stainless steel, tile, wood, and carpet. The food types were watermelon, bread, bread with butter, and gummy candy. Surfaces (25 cm(2)) were spot inoculated with 1 ml of inoculum and allowed to dry for 5 h, yielding an approximate concentration of 10(7) CFU/surface. Foods (with a 16-cm(2) contact area) were dropped onto the surfaces from a height of 12.5 cm and left to rest as appropriate. Posttransfer, surfaces and foods were placed in sterile filter bags and homogenized or massaged, diluted, and plated on tryptic soy agar. The transfer rate was quantified as the log percent transfer from the surface to the food. Contact time, food, and surface type all had highly significant effects (P < 0.000001) on the log percent transfer of bacteria. The inoculum matrix (tryptic soy broth or peptone buffer) also had a significant effect on transfer (P = 0.013), and most interaction terms were significant. More bacteria transferred to watermelon (∼0.2 to 97%) than to any other food, while the least bacteria transferred to gummy candy (∼0.1 to 62%). Transfer of bacteria to bread (∼0.02 to 94%) was similar to transfer of bacteria to bread with butter (∼0.02 to 82%), and these transfer rates under a given set of conditions were more variable than with watermelon and gummy candy.

  13. A fresh liver agar substrate for rearing small numbers of forensically important blow flies (Diptera: Calliphoridae)

    USGS Publications Warehouse

    Gruner, Susan V.; Slone, Daniel H.

    2014-01-01

    Forensically important calliphorids can be reared on a mixture of beef liver and agar. Small pieces of meat, especially fresh or frozen beef liver, will desiccate in 2–6 h, but this simple-to-make feeding substrate remains moist for at least 12 h at 25 and 30°C without desiccation, even in small (5 g) amounts. We determined the survivorship of small numbers of Chrysomya megacephala (F.) (first-instar larvae to adult eclosion) raised on 5 g of liver agar and fresh beef liver. We found that all larvae raised on 5 g of liver died due to desiccation, but survivorship on 5 g of liver agar was equivalent to that on larger (50 g) pieces of either liver agar or beef liver.

  14. A fresh liver agar substrate for rearing small numbers of forensically important blow flies (Diptera: Calliphoridae).

    PubMed

    Gruner, Susan V; Slone, Daniel H

    2014-05-01

    Forensically important calliphorids can be reared on a mixture of beef liver and agar. Small pieces of meat, especially fresh or frozen beef liver, will desiccate in 2-6 h, but this simple-to-make feeding substrate remains moist for at least 12 h at 25 and 30 degrees C without desiccation, even in small (5 g) amounts. We determined the survivorship of small numbers of Chrysomya megacephala (F.) (first-instar larvae to adult eclosion) raised on 5 g of liver agar and fresh beef liver. We found that all larvae raised on 5 g of liver died due to desiccation, but survivorship on 5 g of liver agar was equivalent to that on larger (50 g) pieces of either liver agar or beef liver.

  15. Proton beam writing of microstructures in Agar gel for patterned cell growth

    NASA Astrophysics Data System (ADS)

    Larisch, Wolfgang; Koal, Torsten; Werner, Ronald; Hohlweg, Marcus; Reinert, Tilo; Butz, Tilman

    2011-10-01

    A rather useful prerequisite for many biological and biophysical studies, e.g., for cell-cell communication or neuronal networks, is confined cell growth on micro-structured surfaces. Solidified Agar layers have smooth surfaces which are electrically neutral and thus inhibit receptor binding and cell adhesion. For the first time, Agar microstructures have been manufactured using proton beam writing (PBW). In the irradiated Agar material the polysaccharides are split into oligosaccharides which can easily be washed off leaving Agar-free areas for cell adhesion. The beam diameter of 1 μm allows the fabrication of compartments accommodating single cells which are connected by micrometer-sized channels. Using the external beam the production process is very fast. Up to 50 Petri dishes can be produced per day which makes this technique very suitable for biological investigations which require large throughputs.

  16. Reducing contact resistance at semiconductor to metal or aluminum to metal interfaces

    NASA Technical Reports Server (NTRS)

    Keller, K. R.

    1969-01-01

    Etchant containing chloroplatinous or chloroplatinic acid greatly reduces contact resistance between metallic surfaces. Etching results in a monolayer plating of platinum on the wafer surface, preventing oxide growth.

  17. Genome Sequence of the Agar-Degrading Marine Bacterium Alteromonadaceae sp. Strain G7

    PubMed Central

    Kwak, Min-Jung; Song, Ju Yeon; Kim, Byung Kwon; Chi, Won-Jae; Kwon, Soon-Kyeong; Choi, Soobeom; Chang, Yong-Keun

    2012-01-01

    Here, we present the high-quality draft genome sequence of the agar-degrading marine gammaproteobacterium Alteromonadaceae sp. strain G7, which was isolated from coastal seawater to be utilized as a bioresource for production of agar-derived biofuels. The 3.91-Mb genome contains a number of genes encoding algal polysaccharide-degrading enzymes such as agarases and sulfatases. PMID:23209220

  18. Isolation of Asticcacaulis sp. SA7, a novel agar-degrading alphaproteobacterium.

    PubMed

    Hosoda, Akifumi; Sakai, Masao

    2006-03-01

    An agar-degrading bacterium, strain SA7, was isolated from plant roots cultivated in soil. Analysis of the 16S rDNA sequence showed that strain SA7 is affiliated with the genus Asticcacaulis. Strain SA7 produced extracellular agarase, and grew utilizing agar in the culture medium as sole carbon source. Zymogram analysis showed that strain SA7 extracellularly secreted single agarase protein (about 70 kDa).

  19. Low density, microcellular, dopable, agar/gelatin foams for pulsed power experiments

    SciTech Connect

    McNamara, W.F.; Aubert, J.H.

    1997-04-01

    Low-density, microcellular foams prepared from the natural polymers agar and gelatin have been developed for pulsed-power physics experiments. Numerous experiments were supported with foams having densities at or below 10 mg/cm{sup 3}. For some of the experiments, the agar/gelatin foam was uniformly doped with metallic elements using soluble salts. Depending on the method of preparation, cell sizes were typically below 10 microns and for one process were below 1.0 micron.

  20. Growth and phenotypic characterization of Legionella species on semisolid media made with washed agar.

    PubMed Central

    Rogers, J E; Jones, G W; Engleberg, N C

    1993-01-01

    Legionella pneumophila (and 28 Legionella species) grew efficiently on charcoal-free, buffered yeast extract medium made with washed agar and without apparent loss of infectivity for U937 cells. Because charcoal-free, buffered yeast extract is transparent, it is a suitable base for indicator media and pigment detection. In standard media, charcoal apparently prevents agar contaminants from inhibiting Legionella growth. Images PMID:8417021

  1. Use of benzimidazole agar plates to assess fall armyworm (Lepidoptera: Noctuidae) feeding on excised maize and sorghum leaves

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The fall armyworm, Spodoptera frugiperda (J.E. Smith) (Lepidoptera: Noctuidae) is an economically significant pest of sorghum and maize. To screen sorghum and maize germplasm for resistance to fall armyworm feeding, field, greenhouse, or lab bioassays are often utilized individually or in combinatio...

  2. A Direct Quantitative Agar-Plate Based Assay for Analysis of Pseudomonas protegens PF-5 Degradation of Polyurethane Films (Postprint)

    DTIC Science & Technology

    2014-10-02

    al., 2012) that can metabolize citrate for the degradation of ni- trates and aromatic compounds (Elefsiniotis et al., 2004; Yang et al., 2012). Citrate...detergent and DI water for 1 h, and 3 15 min sonicated rinses in DI water followed by a final sonicated rinse in 100% ethanol . Coupons were dried in a...regions. Removal of the culture from the coated coupons was attempted using either sonication, swabbing, or dipping of coupons in ethanol , but typically

  3. Sputtering and ion plating

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The proceedings of a conference on sputtering and ion plating are presented. Subjects discussed are: (1) concepts and applications of ion plating, (2) sputtering for deposition of solid film lubricants, (3) commercial ion plating equipment, (4) industrial potential for ion plating and sputtering, and (5) fundamentals of RF and DC sputtering.

  4. [GROWTH OF MICROMYCETES FROM DIFFERENT ECOLOGICAL NICHES ON AGAR NUTRIENT MEDIA].

    PubMed

    Kurchenko, I M; Yurieva, E M; Voychuk, S I

    2015-01-01

    Radial growth rate of (K(r)) 153 strains 6 species of micromycetes from different ecological niches was studied on 7 agar media: three standard (malt extract agar, potato-dextrose agar, Czapek's agar), and on agar media with plant polymers (carboxymethylcellulose, xylan, soluble starch and apple pectin). Endophytic and plant pathogenic strains (biotrophs) of all studied species did not differ significantly in their ability to grow on nutrient media of different composition--average values of K(r) for these two groups were the same (0,200 and 0,199 mm/h, respectively). Soil micromycetes (saprophytes) characterized by the lowest average growth rate (0,169 mm/h) and significantly differed from the endophytic and plant pathogenic ones. Average of the radial growth rates of studied microscopic fungi were higher on standard nutrient media than with plant polymers ones. Growth parameters of endophytes and plant pathogens of all studied species on various agar media differed from the soil strains. High growth rate of endophytic and plant pathogenic strains of Fusarium poae, Alternaria alternata and Ceratocystis sp. provides them the rapid colonization of plants. Penicillium funiculosum strains equally can exist as saprophytes in soil and as endophytic plant symbionts. A wide range of K(r) variation of endophytic dark pigmented Mycelia sterilia indicates the presence in this group of different species of micromycetes, which have no sporulation.

  5. Complex impedance and conductivity of agar-based ion-conducting polymer electrolytes

    NASA Astrophysics Data System (ADS)

    Nwanya, A. C.; Amaechi, C. I.; Udounwa, A. E.; Osuji, R. U.; Maaza, M.; Ezema, F. I.

    2015-04-01

    Agar-based electrolyte standing films with different salts and weak acids as ion and proton conductors were prepared and characterized by X-ray diffraction, UV-visible spectrophotometry, photoluminescence emission spectroscopy and electrochemical impedance spectroscopy. The salts used are lithium perchlorate (LiClO4) and potassium perchlorate (KClO4), while the weak acids used are acetic acid (CH3COOH) and lactic acid (C3H6O3). The values of the ion conductivity obtained for the agar-based polymer films are 6.54 × 10-8, 9.12 × 10-8, 3.53 × 10-8, 2.24 × 10-8 S/cm for the agar/acetic acid, agar/lactic acid, agar/LiClO4 and agar/KClO4 polymer films, respectively. As a function of temperature, the ion conductivity exhibits an Arrhenius behavior and the estimated activation energy is ≈0.1 eV for all the samples. The samples depicted high values of dielectric permittivity toward low frequencies which is due mostly to electrode polarization effect. The samples showed very high transparency (85-98 %) in the visible region, and this high transparency is one of the major requirements for application in electrochromic devices (ECD). The values of conductivity and activation energy obtained indicate that the electrolytes are good materials for application in ECD.

  6. Contact Resistance Characteristics of Improved Conductive Elastomer Contacts for Contaminated Printed Circuit Board in SO2 Environment

    NASA Astrophysics Data System (ADS)

    Tamai, Terutaka; Saitoh, Yasushi; Hattori, Yasuhiro; Ikeda, Hirosaka

    Characteristics of conductive elastomer that is composed of silicone rubber and dispersed carbon black particles show conductive and elastic properties in one simple material. This material has been widely applied to make-break contacts of panel switches and connectors of liquid crystal panels. However, since surface state of the contact is very soft, it is difficult to remove contaminant films of contaminated opposite side contact surface and to obtain low contact resistance owing to break the film. This is an important problem to be solved not only for the application of make-break switching contact but also static connector contacts. This study has been conducted to examine some complex structures of the elastomer which indicate removal characteristics for contaminant films and low contact resistance. As specimens, six different types of elastomer contacts composed of different type of dispersed materials as carbon and metal fibers, metal mesh, and plated surfaces were used. The contacts of opposite side were Au and Sn plated contact surface on a printed circuit board (PCB) which is usually used in the static connector and make-break contacts. In order to contaminate contact surfaces of PCB, the surfaces were subjected to exposure in an SO2 gas environment. The elastomeric contacts contained hard materials showed lower contact resistance than only dispersed carbon particles in the elastomer matrix for both contaminated PCB contact surfaces.

  7. EDITORIAL: Close contact Close contact

    NASA Astrophysics Data System (ADS)

    Demming, Anna

    2010-07-01

    The development of scanning probe techniques, such as scanning tunnelling microscopy [1], has often been touted as the catalyst for the surge in activity and progress in nanoscale science and technology. Images of nanoscale structural detail have served as an invaluable investigative resource and continue to fascinate with the fantastical reality of an intricate nether world existing all around us, but hidden from view of the naked eye by a disparity in scale. As is so often the case, the invention of the scanning tunnelling microscope heralded far more than just a useful new apparatus, it demonstrated the scope for exploiting the subtleties of electronic contact. The shrinking of electronic devices has been a driving force for research into molecular electronics, in which an understanding of the nature of electronic contact at junctions is crucial. In response, the number of experimental techniques in molecular electronics has increased rapidly in recent years. Scanning tunnelling microscopes have been used to study electron transfer through molecular films on a conducting substrate, and the need to monitor the contact force of scanning tunnelling electrodes led to the use of atomic force microscopy probes coated in a conducting layer as studied by Cui and colleagues in Arizona [2]. In this issue a collaboration of researchers at Delft University and Leiden University in the Netherlands report a new device architecture for the independent mechanical and electrostatic tuning of nanoscale charge transport, which will enable thorough studies of molecular transport in the future [3]. Scanning probes can also be used to pattern surfaces, such as through spatially-localized Suzuki and Heck reactions in chemical scanning probe lithography. Mechanistic aspects of spatially confined Suzuki and Heck chemistry are also reported in this issue by researchers in Oxford [4]. All these developments in molecular electronics fabrication and characterization provide alternative

  8. Modification of kanamycin-esculin-azide agar to improve selectivity in the enumeration of fecal streptococci from water samples.

    PubMed Central

    Audicana, A; Perales, I; Borrego, J J

    1995-01-01

    Kanamycin-esculin-azide agar was modified by increasing the concentration of sodium azide to 0.4 g liter-1 and replacing kanamycin sulfate with 5 mg of oxolinic acid liter-1. The modification, named oxolinic acid-esculin-azide (OAA) agar, was compared with Slanetz-Bartley and KF agars by using drinking water and seawater samples. The OAA agar showed higher specificity, selectivity, and recovery efficiencies than those obtained by using the other media. In addition, no confirmation of typical colonies was needed when OAA agar was used, which significantly shortens the time of sample processing and increases the accuracy of the method. PMID:8534085

  9. Plate Tectonics and Continental Drift: Classroom Ideas.

    ERIC Educational Resources Information Center

    Stout, Prentice K.

    1983-01-01

    Suggests various classroom studies related to plate tectonics and continental drift, including comments on and sources of resource materials useful in teaching the topics. A complete list of magazine articles on the topics from the Sawyer Marine Resource Collection may be obtained by contacting the author. (JN)

  10. Sliding contacts on printed circuit boards and wear behavior

    NASA Astrophysics Data System (ADS)

    Le Solleu, J.-P.

    2010-04-01

    Automotive suppliers use since decades printed circuit boards (PCB) gold plating pads, as direct contact interface for low current sliding contacts. Several gold plating processes are available on the market, providing various wear behaviour. Some specific galvanic hard gold (AuCo or AuNi). plating was developed on PCB's. This specific plating generates extra costs due to the material quantity and also the process complexity. In a cost driven industry, the challenge is to use a standard low cost PCB for systems requesting high reliability performances. After a brief overview of standard PCB manufacturing processes and especially gold plating processes, the global experimental results of wear behaviour of three different gold plating technologies will be exposed and an explanation of the correlation between surface key parameters and wear out will be provided.

  11. Inactivation of avirulent Yersinia pestis on food and food contact surfaces by ultraviolet light and freezing.

    PubMed

    Sommers, Christopher H; Sheen, Shiowshuh

    2015-09-01

    Yersinia pestis, the causative agent of plague, can occasionally be contracted as a naso-pharyngeal or gastrointestinal illness through consumption of contaminated meat. In this study, the use of 254 nm ultraviolet light (UV-C) to inactivate a multi-isolate cocktail of avirulent Y. pestis on food and food contact surfaces was investigated. When a commercial UV-C conveyor was used (5 mW/cm(2)/s) 0.5 J/cm(2) inactivated >7 log of the Y. pestis cocktail on agar plates. At 0.5 J/cm(2), UV-C inactivated ca. 4 log of Y. pestis in beef, chicken, and catfish, exudates inoculated onto high density polypropylene or polyethylene, and stainless steel coupons, and >6 log was eliminated at 1 J/cm(2). Approximately 1 log was inactivated on chicken breast, beef steak, and catfish fillet surfaces at a UV-C dose of 1 J/cm(2). UV-C treatment prior to freezing of the foods did not increase the inactivation of Y. pestis over freezing alone. These results indicate that routine use of UV-C during food processing would provide workers and consumers some protection against Y. pestis.

  12. Pressurized bellows flat contact heat exchanger interface

    NASA Technical Reports Server (NTRS)

    Voss, Fred E. (Inventor); Howell, Harold R. (Inventor); Winkler, Roger V. (Inventor)

    1990-01-01

    Disclosed is an interdigitated plate-type heat exchanger interface. The interface includes a modular interconnect to thermally connect a pair or pairs of plate-type heat exchangers to a second single or multiple plate-type heat exchanger. The modular interconnect comprises a series of parallel, plate-type heat exchangers arranged in pairs to form a slot therebetween. The plate-type heat exchangers of the second heat exchanger insert into the slots of the modular interconnect. Bellows are provided between the pairs of fins of the modular interconnect so that when the bellows are pressurized, they drive the plate-type heat exchangers of the modular interconnect toward one another, thus closing upon the second heat exchanger plates. Each end of the bellows has a part thereof a thin, membrane diaphragm which readily conforms to the contours of the heat exchanger plates of the modular interconnect when the bellows is pressurized. This ensures an even distribution of pressure on the heat exchangers of the modular interconnect thus creating substantially planar contact between the two heat exchangers. The effect of the interface of the present invention is to provide a dry connection between two heat exchangers whereby the rate of heat transfer can be varied by varying the pressure within the bellows.

  13. Evaluation of CP Chromo Select Agar for the enumeration of Clostridium perfringens from water.

    PubMed

    Manafi, Mammad; Waldherr, Kerstin; Kundi, Michael

    2013-10-01

    The European Directive on drinking water quality has included mCP agar as the reference method for recovering Clostridium perfringens from drinking waters. In the present study, three media (mCP, TSCF and CP Chromo Select Agar) were evaluated for recovery of C. perfringens in different surface water samples. Out of 139 water samples, using a membrane filtration technique, 131 samples (94.2%) were found to be presumptively positive for C. perfringens in at least one of the culture media. Green colored colonies on CP Chromo Select Agar (CCP agar) were counted as presumptive C. perfringens isolates. Out of 483 green colonies on CCP agar, 96.3% (465 strains, indole negative) were identified as C. perfringens, and 15 strains (3.1%) were indole positive and were identified as Clostridium sordellii, Clostridium bifermentans or Clostridium tetani. Only 3 strains (0.6%) gave false positive results and were identified as Clostridium fallax, Clostridium botulinum, and Clostridium tertium. Variance analysis of the data obtained shows statistically no significant differences in the counts obtained between media employed in this work. The mCP method is very onerous for routine screening and bacterial colonies could not be used for further biochemical testing. The colonies on CCP and TSCF were easy to count and subculture for confirmation tests. TSCF detects sulfite-reducing clostridia, including species other than C. perfringens, and in some cases excessive blackening of the agar frustrated counting of the colonies. If the contamination was too high, TSCF did not consistently produce black colonies and as a consequence, the colonies were white and gave false negative results. On the other hand, the identification of typical and atypical colonies isolated from all media demonstrated that CCP agar was the most useful medium for C. perfringens recovery in water samples.

  14. Preparation and characterization of bio-nanocomposite films of agar and silver nanoparticles: laser ablation method.

    PubMed

    Rhim, Jong-Whan; Wang, Long-Feng; Lee, Yonghoon; Hong, Seok-In

    2014-03-15

    Silver nanoparticles (AgNPs) were prepared by a laser ablation method and composite films with the AgNPs and agar were prepared by solvent casting method. UV-vis absorbance test and transmission electron microscopy (TEM) analysis results revealed that non-agglomerated spherical AgNPs were formed by the laser ablation method. The surface color of the resulting agar/AgNPs films exhibited the characteristic plasmonic effect of the AgNPs with the maximum absorption peaks of 400-407 nm. X-ray diffraction (XRD) test results also exhibited characteristic AgNPs crystals with diffraction peaks observed at 2θ values of 38.39°, 44.49°, and 64.45°, which were corresponding to (111), (200), and (220) crystallographic planes of face-centered cubic (fcc) silver crystals, respectively. Thermogravimetric analysis (TGA) results showed that thermal stability of the agar/AgNPs composite films was increased by the inclusion of metallic silver. Water vapor barrier properties and surface hydrophobicity of the agar/AgNPs films increased slightly with the increase in AgNPs content but they were not statistically significant (p>0.05), while mechanical strength and stiffness of the composite films decreased slightly (p<0.05). The agar/AgNPs films exhibited distinctive antimicrobial activity against both Gram-positive (Listeria monocytogenes) and Gram-negative (Escherichia coli O157:H7) bacterial pathogens.

  15. Characterization of bionanocomposite films prepared with agar and paper-mulberry pulp nanocellulose.

    PubMed

    Reddy, Jeevan Prasad; Rhim, Jong-Whan

    2014-09-22

    Crystallized nanocellulose (CNC) was separated from paper-mulberry (Broussonetia kazinoki Siebold) bast pulp by sulfuric acid hydrolysis method and they were blended with agar to prepare bionanocomposite films. The effect of CNC content (1, 3, 5 and 10 wt% based on agar) on the mechanical, water vapor permeability (WVP), and thermal properties of the nanocomposites were studied. Changes of the cellulose fibers in structure, morphology, crystallinity, and thermal properties of the films were evaluated using FT-IR, TEM, SEM, XRD, and TGA analysis methods. The CNC was composed of fibrous and spherical or elliptic granules of nano-cellulose with sizes of 50-60 nm. Properties of agar film such as mechanical and water vapor barrier properties were improved significantly (p<0.05) by blending with the CNC. The tensile modulus and tensile strength of agar film increased by 40% and 25%, respectively, in the composite film with 5 wt% of CNC, and the WVP of agar film decreased by 25% after formation of nanocomposite with 3 wt% of CNC. The CNC obtained from the paper-mulberry bast pulp can be used as a reinforcing agent for the preparation of bio-nanocomposites, and they have a high potential for the development of completely biodegradable food packaging materials.

  16. Strategies to improve the mechanical strength and water resistance of agar films for food packaging applications.

    PubMed

    Sousa, Ana M M; Gonçalves, Maria P

    2015-11-05

    Agar films possess several properties adequate for food packaging applications. However, their high cost-production and quality variations caused by physiological and environmental factors affecting wild seaweeds make them less attractive for industries. In this work, native (NA) and alkali-modified (AA) agars obtained from sustainably grown seaweeds (integrated multi-trophic aquaculture) were mixed with locust bean gum (LBG) to make 'knife-coated' films with fixed final concentration (1 wt%) and variable agar/LBG ratios. Agar films were easier to process upon LBG addition (viscosity increase and gelling character decrease of the film-forming solutions observed by dynamic oscillatory and steady shear measurements). The mechanical properties and water resistance were optimal for films with 50 and/or 75% LBG contents and best in the case of NA (cheaper to extract). These findings can help reduce the cost-production of agar packaging films. Moreover, the controlled cultivation of seaweeds can provide continuous and reliable feedstock for transformation industries.

  17. Immobilization of urease from pigeonpea (Cajanus cajan) on agar tablets and its application in urea assay.

    PubMed

    Mulagalapalli, Swati; Kumar, Sandeep; Kalathur, Ravi Charan Reddy; Kayastha, Arvind M

    2007-09-01

    The pigeonpea urease was immobilized on agar, a common gelling substance. The tablet strips were used as moulds to cast agar tablets of uniform shape and size. The time and temperature of solidification of agar was 6 min and 44 degrees C, respectively. The 5 % agar (w/v) and 0.019 mg protein/agar tablet yielded an optimum immobilization of 51.7%. The optimum pH was shifted through 0.2 U (from 7.3 to 7.5) towards basic side upon immobilization. The optimum temperature of soluble and immobilized urease was 30 degrees C and 60 degrees C, respectively, showing the improvement in thermal stability of urease. There was an increase in K m from 3.23 to 5.07 mM after immobilization. The half-lives of soluble and immobilized urease were 21 and 53 days, respectively, at pH 7.3 and 4 degrees C. The urea was estimated in different blood samples with the help of immobilized urease and the results were consistent with those from clinical pathology laboratory through an autoanalyzer (Zydus Co., Rome, Italy).

  18. Comparison of agar-based media for primary isolation of glycopeptide-resistant enterococci.

    PubMed

    Chadwick, P. R.; Brown, D. F. J.; Wilcox, M. H.; Collyns, T. A.; Walpole, E.; Dillon, J.; Smith, R.; Gopal Rao, G.; Oppenheim, B. A.

    1997-01-01

    OBJECTIVE: To compare four vancomycin-containing agar media for the isolation of glycopeptide-resistant enterococci (GRE) from clinical fecal specimens: kanamycin---aesculin---azide (KAA) agar; bile---aesculin---polymixin (BAP) agar; aztreonam---amphotericin blood (CBAA) agar; and neomycin blood (CBN) agar. METHODS: Fecal specimens from 125 patients were inoculated onto each medium. Media were examined for enterococci after incubation for up to 48 h. Enterococci were identified to species level, and glycopeptide phenotypes were determined by measuring minimum inhibitory concentrations of vancomycin and teicoplanin. RESULTS: GRE were isolated from 44/125 samples. Enterococcus faecalis and Enterococcus faecium isolates, expressing glycopeptide resistance of the VanA or VanB phenotypes, were recovered from 27/33 (82%) specimens on BAP medium, 26/33 (79%) on KAA medium, and 21/33 (64%) on CBN and CBAA media. Enterococcus gallinarum and Enterococcus casseliflavus isolates expressing low-level glycopeptide resistance (VanC phenotype) were recovered from 14/15 (93%) specimens on CBAA medium, 7/15 (47%) on KAA and CBN media, and 6/15 (40%) on BAP medium. CONCLUSIONS: The media tested in this study, with the exception of CBN medium, detected at least 75% of patients colonized by GRE. Further development of BAP, CBAA and KAA media is warranted to improve growth and selectivity.

  19. Antimicrobial and physical-mechanical properties of agar-based films incorporated with grapefruit seed extract.

    PubMed

    Kanmani, Paulraj; Rhim, Jong-Whan

    2014-02-15

    The use of synthetic petroleum based packaging films caused serious environmental problems due to their difficulty in recycling and poor biodegradability. Therefore, present study was aimed to develop natural biopolymer-based antimicrobial packaging films as an alternative for the synthetic packaging films. As a natural antimicrobial agent, grapefruit seed extract (GSE) has been incorporated into agar to prepare antimicrobial packaging film. The films with different concentrations of GSE were prepared by a solvent casting method and the resulting composite films were examined physically and mechanically. In addition, the films were characterized by FE-SEM, XRD, FT-IR and TGA. The incorporation of GSE caused increase in color, UV barrier, moisture content, water solubility and water vapor permeability, while decrease in surface hydrophobicity, tensile strength and elastic modulus of the films. As the concentration of GSE increased from 0.6 to 13.3 μg/mL, the physical and mechanical properties of the films were affected significantly. The addition of GSE changed film microstructure of the film, but did not influence the crystallinity of agar and thermal stability of the agar-based films. The agar/GSE films exhibited distinctive antimicrobial activity against three test food pathogens, such as Listeria monocytogenes, Bacillus cereus and Escherichia coli. These results suggest that agar/GSE films have potential to be used in an active food packaging systems for maintaining food safety and extending the shelf-life of the packaged food.

  20. Effects of shape and size of agar gels on heating uniformity during pulsed microwave treatment.

    PubMed

    Soto-Reyes, Nohemí; Temis-Pérez, Ana L; López-Malo, Aurelio; Rojas-Laguna, Roberto; Sosa-Morales, María Elena

    2015-05-01

    Model gel systems with different shape (sphere, cylinder, and slab) and size (180 and 290 g) were prepared with agar (5%) and sucrose (5%). Dielectric constant (ε'), loss factor (ε"), thermophysical properties, and temperature distribution of the model system were measured. Each agar model system was immersed and suspended in water, and then, heated in a microwave oven with intermittent heating until the core temperature reached 50 °C. The ε' and ε" of agar gels decreased when frequency increased. The density and thermal conductivity values of the agar gels were 1033 kg/m(3) and 0.55 W/m °C, respectively. The temperature distribution of sphere, cylinder, and slab was different when similar power doses were applied. The slab reached 50 °C in less time (10 min) and showed a more uniform heating than spheres and cylinders in both sizes. Agar model systems of 180 g heated faster than those of 290 g. The coldest point was the center of the model systems in all studied cases. Shape and size are critical food factors that affect the heating uniformity during microwave heating processes.

  1. Earth's Decelerating Tectonic Plates

    SciTech Connect

    Forte, A M; Moucha, R; Rowley, D B; Quere, S; Mitrovica, J X; Simmons, N A; Grand, S P

    2008-08-22

    Space geodetic and oceanic magnetic anomaly constraints on tectonic plate motions are employed to determine a new global map of present-day rates of change of plate velocities. This map shows that Earth's largest plate, the Pacific, is presently decelerating along with several other plates in the Pacific and Indo-Atlantic hemispheres. These plate decelerations contribute to an overall, globally averaged slowdown in tectonic plate speeds. The map of plate decelerations provides new and unique constraints on the dynamics of time-dependent convection in Earth's mantle. We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data to show that time-dependent changes in mantle buoyancy forces can explain the deceleration of the major plates in the Pacific and Indo-Atlantic hemispheres.

  2. Thermal, mechanical, and physical properties of seaweed/sugar palm fibre reinforced thermoplastic sugar palm Starch/Agar hybrid composites.

    PubMed

    Jumaidin, Ridhwan; Sapuan, Salit M; Jawaid, Mohammad; Ishak, Mohamad R; Sahari, Japar

    2017-04-01

    The aim of this research is to investigate the effect of sugar palm fibre (SPF) on the mechanical, thermal and physical properties of seaweed/thermoplastic sugar palm starch agar (TPSA) composites. Hybridized seaweed/SPF filler at weight ratio of 25:75, 50:50 and 75:25 were prepared using TPSA as a matrix. Mechanical, thermal and physical properties of hybrid composites were carried out. Obtained results indicated that hybrid composites display improved tensile and flexural properties accompanied with lower impact resistance. The highest tensile (17.74MPa) and flexural strength (31.24MPa) was obtained from hybrid composite with 50:50 ratio of seaweed/SPF. Good fibre-matrix bonding was evident in the scanning electron microscopy (SEM) micrograph of the hybrid composites' tensile fracture. Fourier transform infrared spectroscopy (FT-IR) analysis showed increase in intermolecular hydrogen bonding following the addition of SPF. Thermal stability of hybrid composites was enhanced, indicated by a higher onset degradation temperature (259°C) for 25:75 seaweed/SPF composites than the individual seaweed composites (253°C). Water absorption, thickness swelling, water solubility, and soil burial tests showed higher water and biodegradation resistance of the hybrid composites. Overall, the hybridization of SPF with seaweed/TPSA composites enhances the properties of the biocomposites for short-life application; that is, disposable tray, plate, etc.

  3. Accelerated plate tectonics.

    PubMed

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence.

  4. Homogeneous Matrix Deposition on Dried Agar for MALDI Imaging Mass Spectrometry of Microbial Cultures

    NASA Astrophysics Data System (ADS)

    Hoffmann, Thomas; Dorrestein, Pieter C.

    2015-11-01

    Matrix deposition on agar-based microbial colonies for MALDI imaging mass spectrometry is often complicated by the complex media on which microbes are grown. This Application Note demonstrates how consecutive short spray pulses of a matrix solution can form an evenly closed matrix layer on dried agar. Compared with sieving dry matrix onto wet agar, this method supports analyte cocrystallization, which results in significantly more signals, higher signal-to-noise ratios, and improved ionization efficiency. The even matrix layer improves spot-to-spot precision of measured m/z values when using TOF mass spectrometers. With this technique, we established reproducible imaging mass spectrometry of myxobacterial cultures on nutrient-rich cultivation media, which was not possible with the sieving technique.

  5. [DNA and chemical analyses of commercial fly agaric-related products].

    PubMed

    Maruyama, Takuro; Kawahara, Nobuo; Fukiharu, Toshimitsu; Yokoyama, Kazumasa; Makino, Yukiko; Goda, Yukihiro

    2005-04-01

    Since June 6, 2002, psilocin and psilocybin-containing fungi (commonly called "magic mushrooms") have been regulated by the Narcotics and Psychotropics Control Law in Japan. However, various fly agaric-related products are now entering the Japanese market via the internet. In this study, fly agaric-related products available in this way were investigated for raw materials by DNA analysis and for additives by chemical analysis. Nucleotide sequence analysis of the mitochondrial 12S rDNA region suggested that these fly agaric-related products originate from A. muscaria or A. muscaria var. persicina. Furthermore, they were classified into three strains based on the ITS2-LSU nucleotide sequence. Harmine derivatives and/or tryptamine derivatives were detected in some of these products by LC/MS analysis. In accordance with this, the matK gene of Peganum harmala was found in all of the harmine derivative-containing samples.

  6. Expression of an accessory cell phenotype by hairy cells during lymphocyte colony formation in agar culture.

    PubMed

    Farcet, J P; Gourdin, M F; Testa, U; Andre, C; Jouault, H; Reyes, F

    1983-01-01

    Human T lymphocytes require the cooperation of accessory cells to generate lymphocyte colonies in agar culture under PHA stimulation. Various hairy cell enriched fractions, as well as normal monocytes, have been found to be able to initiate colony formation by normal lymphocytes. Leukemic monocytes from CMML patients were also effective, but not the leukemic lymphocytes from CLL patients. The phenotype expressed by HC in agar colonies was further studied using cell surface and enzymatic markers. We have concluded that HC in agar culture in the presence of both normal T lymphocytes and PHA lose the B phenotype that they express in vivo and function like an accessory cell in contrast to normal or leukemic B lymphocytes.

  7. Eradication of bovine leukemia virus infection in commercial dairy herds using the agar gel immunodiffusion test.

    PubMed Central

    Shettigara, P T; Samagh, B S; Lobinowich, E M

    1986-01-01

    Demands for bovine leukemia virus test negative breeding cattle and for semen from bovine leukemia virus test negative bulls by several countries have encouraged the eradication of bovine leukemia virus infection from selected herds in Canada. This project was undertaken to evaluate the suitability of the agar gel immunodiffusion test, standardized to detect anti-bovine leukemia virus glycoprotein antibodies, for eradication of bovine leukemia virus from commercial dairy herds. Of nine participating herds, the prevalence rate of bovine leukemia virus infection was low (less than 10%) in three, medium (11-30%) in four and high (greater than 30%) in two. The herds were tested by the agar gel immunodiffusion test, reactors were removed and the herds were then retested at regular intervals. The results indicate that it is possible to eliminate bovine leukemia virus infection from the herds after two to three cycles of agar gel immunodiffusion tests and prompt removal of the reactors. PMID:3019498

  8. Use of Rambach Propylene Glycol Containing Agar for identification of Salmonella spp.

    PubMed

    Gruenewald, R; Henderson, R W; Yappow, S

    1991-10-01

    When grown on Rambach Propylene Glycol Containing Agar (Rambach agar), 216 of 230 (93.9%) Salmonella organisms isolated from patients and 54 of 62 (87.1%) Salmonella stock cultures produced a crimson-colored growth. Of the 14 clinical Salmonella isolates which displayed colors other than crimson, 8 were Salmonella typhi, 2 were Salmonella paratyphi A, and 4 belonged to other commonly isolated serotypes. All eight Salmonella stock cultures which failed to produce a crimson color belonged to rarely isolated serotypes. In contrast, of 83 non-Salmonella stock cultures distributed among 29 bacterial species, none produced a crimson color. These results suggest that while Rambach agar cannot preidentify S. typhi and S. paratyphi A, the medium can be used for the presumptive identification and can assist in the definitive identification of the overwhelming majority of Salmonella isolates.

  9. [Presumptive identification of Candida spp. and other clinically important yeasts: usefulness of Brilliance Candida Agar].

    PubMed

    Alfonso, Claudia; López, Mónica; Arechavala, Alicia; Perrone, María Del Carmen; Guelfand, Liliana; Bianchi, Mario

    2010-06-30

    Fungal infections caused by yeasts have increased during the last decades and invasive forms represent a serious problem for human health. Candida albicans is the species most frequently isolated from clinical samples. However, other emerging yeast pathogens are increasingly responsible for mycotic infections, and some of them are resistant to some antifungal drugs. Consequently, it is necessary to have methods that can provide a rapid presumptive identification at species level. Numerous chromogenic agar media have been shown to be of value as diagnostic tools. We have compared a chromogenic medium, Brilliance Candida Agar, with CHROMagar Candida, the chromogenic medium most used in our country. A multicentre study was conducted in 16 Hospitals belonging to the Mycology Net of Buenos Aires City Government. A total of 240 yeast isolates were included in this research. The new chromogenic agar showed results very similar to those obtained with CHROMagar Candida.

  10. Agar blue localization of small pulmonary nodules and ground glass opacifications for thoracoscopic resection

    PubMed Central

    2016-01-01

    Background Screening for lung cancer using high resolution computed tomography (CT) has produced encouraging early results. Extremely small nodules and non-palpable areas of opacifications are able to be detected, but pose a challenge to the thoracic surgeon trying to resect these areas. Methods Forty five patients with ground glass opacifications (GGOs) or small pulmonary nodules underwent pre-operative CT-guided placement of methylene blue dyed agar and/or hook wire needle localization prior to thoracoscopic resection. Progel was applied to any intraoperative air leaks observed after successful resection. Results All lesions were successfully excised thoracoscopically. The blue agar aided in localization of these areas and did not affect the histological architecture during pathologic evaluation. Conclusions Careful pre-operative evaluation and planning, including use of selective CT-guided blue agar localization and hook wire placement, may greatly assist in thoracoscopically locating and resecting these often difficult-to-visualize lesions. PMID:28066669

  11. Contact Lens Risks

    MedlinePlus

    ... Health and Consumer Devices Consumer Products Contact Lenses Contact Lens Risks Share Tweet Linkedin Pin it More ... redness blurred vision swelling pain Serious Hazards of Contact Lenses Symptoms of eye irritation can indicate a ...

  12. Contact Lens Care

    MedlinePlus

    ... For Consumers Consumer Information by Audience For Women Contact Lens Care Share Tweet Linkedin Pin it More ... 1088, www.fda.gov/medwatch Learn More about Contact Lens Care Other Tips on Contact Lenses Decorative ...

  13. Obliquity along plate boundaries

    NASA Astrophysics Data System (ADS)

    Philippon, Mélody; Corti, Giacomo

    2016-12-01

    Most of the plate boundaries are activated obliquely with respect to the direction of far field stresses, as roughly only 8% of the plate boundaries total length shows a very low obliquity (ranging from 0 to 10°, sub-orthogonal to the plate displacement). The obliquity along plate boundaries is controlled by (i) lateral rheological variations within the lithosphere and (ii) consistency with the global plate circuit. Indeed, plate tectonics and magmatism drive rheological changes within the lithosphere and consequently influence strain localization. Geodynamical evolution controls large-scale mantle convection and plate formation, consumption, and re-organization, thus triggering plate kinematics variations, and the adjustment and re-orientation of far field stresses. These geological processes may thus result in plate boundaries that are not perpendicular but oblique to the direction of far field stresses. This paper reviews the global patterns of obliquity along plate boundaries. Using GPlate, we provide a statistical analysis of present-day obliquity along plate boundaries. Within this framework, by comparing natural examples and geological models, we discuss deformation patterns and kinematics recorded along oblique plate boundaries.

  14. Plating Tank Control Software

    SciTech Connect

    Krafcik, John

    1998-03-01

    The Plating Tank Control Software is a graphical user interface that controls and records plating process conditions for plating in high aspect ratio channels that require use of low current and long times. The software is written for a Pentium II PC with an 8 channel data acquisition card, and the necessary shunt resistors for measuring currents in the millampere range.

  15. Rotatable shear plate interferometer

    DOEpatents

    Duffus, Richard C.

    1988-01-01

    A rotatable shear plate interferometer comprises a transparent shear plate mounted obliquely in a tubular supporting member at 45.degree. with respect to its horizontal center axis. This tubular supporting member is supported rotatably around its center axis and a collimated laser beam is made incident on the shear plate along this center axis such that defocus in different directions can be easily measured.

  16. A modified feeding plate for a newborn with cleft palate.

    PubMed

    Erkan, Mustafa; Karaçay, Seniz; Atay, Arzu; Günay, Yumuşhan

    2013-01-01

    Objectives : Cleft palate is a common congenital maxillofacial defect. We wish to present the fabrication of a modified feeding plate that will adapt to the changing palatal and velopharyngeal morphology during function. Case Report : A neonate with unilateral cleft lip and palate was referred to our clinic for the fabrication of a feeding plate. Intraoral examination revealed a cleft involving the uvula and the soft palate, with an alveolar defect on the left side. An impression was taken and a dental cast was obtained. A 1-mm Bioplast clear soft plate was pressed on the model. After trimming the edges of the plate, several retentive holes were made for its attachment to the hard plate. With the Bioplast soft plate replaced on the cast, plaster was used to cover parts of the soft plate that were not to come in contact with the hard plate. Biocryl resin was put on the retentive holes and 2-mm Biocryl C Rosa-transparent plate was pressed. The edges of the plate were cut, trimmed, and polished. Conclusion : This modified feeding plate effectively obstructed the soft palate defect. The adaptation of the flexible bulb of the appliance with the soft palate was excellent. Evaluation with nasoendoscopy revealed the synchronized movement of the bulb of the appliance with the soft palate during swallowing. Soft extension of the feeding plate eliminated the risk of irritation, and the baby accepted the appliance easily.

  17. Malachite green photosensitive plates.

    PubMed

    Solano, C

    1989-08-15

    An experimental study of the behavior of malachite green sensitized plates was carried out. The transmittance variation of the irradiated plates was taken as a parameter. It has been observed that photoreduction in the malachite green plates is present only when ammonium dichromate is added to the plates. The introduction of external electron donors does not improve the photochemical reaction. It has been determined that malachite green molecules form a weak complex with the dichromate molecules and this complex can only be destroyed photochemically. This effect can explain the limited response of the malachite green dichromated plates.

  18. An improved plating process

    NASA Technical Reports Server (NTRS)

    Askew, John C.

    1994-01-01

    An alternative to the immersion process for the electrodeposition of chromium from aqueous solutions on the inside diameter (ID) of long tubes is described. The Vessel Plating Process eliminates the need for deep processing tanks, large volumes of solutions, and associated safety and environmental concerns. Vessel Plating allows the process to be monitored and controlled by computer thus increasing reliability, flexibility and quality. Elimination of the trivalent chromium accumulation normally associated with ID plating is intrinsic to the Vessel Plating Process. The construction and operation of a prototype Vessel Plating Facility with emphasis on materials of construction, engineered and operational safety and a unique system for rinse water recovery are described.

  19. New Agar Technique Compared with Sand Flotation for Obtaining Salt Marsh Culicoides mississippiensis Hoffman (Diptera: Ceratopogonidae) Larvae,

    DTIC Science & Technology

    1979-12-26

    compared with 1% and 2% (wt/v) agar formulations for extracting Culicoides ndisaiooippiensis Hoffman larvae from marsh soil samples. The 1% agar formula...been used to recover larvae of biting midges (CuZ.,o;1aa spp .) from salt marsh substrate (soil) samples. They are: (1) sieve-flotation (Kettle and Lawson...Kettle et al., (1975) in which tabanid and culicoid larvae were successfully reared in agar media, we decided that one possibility was to replace the

  20. Multicolor printing plate joining

    NASA Technical Reports Server (NTRS)

    Waters, W. J. (Inventor)

    1984-01-01

    An upper plate having ink flow channels and a lower plate having a multicolored pattern are joined. The joining is accomplished without clogging any ink flow paths. A pattern having different colored parts and apertures is formed in a lower plate. Ink flow channels each having respective ink input ports are formed in an upper plate. The ink flow channels are coated with solder mask and the bottom of the upper plate is then coated with solder. The upper and lower plates are pressed together at from 2 to 5 psi and heated to a temperature of from 295 F to 750 F or enough to melt the solder. After the plates have cooled and the pressure is released, the solder mask is removed from the interior passageways by means of a liquid solvent.

  1. Contact Lenses for Vision Correction

    MedlinePlus

    ... Ophthalmologist Patient Stories Español Eye Health / Glasses & Contacts Contact Lenses Sections Contact Lenses for Vision Correction Proper ... to Know About Contact Lenses Colored Contact Lenses Contact Lenses for Vision Correction Written by: Kierstan Boyd ...

  2. Use of the Soft-agar Overlay Technique to Screen for Bacterially Produced Inhibitory Compounds

    PubMed Central

    Hockett, Kevin L.; Baltrus, David A.

    2017-01-01

    The soft-agar overlay technique was originally developed over 70 years ago and has been widely used in several areas of microbiological research, including work with bacteriophages and bacteriocins, proteinaceous antibacterial agents. This approach is relatively inexpensive, with minimal resource requirements. This technique consists of spotting supernatant from a donor strain (potentially harboring a toxic compound(s)) onto a solidified soft agar overlay that is seeded with a bacterial test strain (potentially sensitive to the toxic compound(s)). We utilized this technique to screen a library of Pseudomonas syringae strains for intraspecific killing. By combining this approach with a precipitation step and targeted gene deletions, multiple toxic compounds produced by the same strain can be differentiated. The two antagonistic agents commonly recovered using this technique are bacteriophages and bacteriocins. These two agents can be differentiated using two simple additional tests. Performing a serial dilution on a supernatant containing bacteriophage will result in individual plaques becoming less in number with greater dilution, whereas serial dilution of a supernatant containing bacteriocin will result a clearing zone that becomes uniformly more turbid with greater dilution. Additionally, a bacteriophage will produce a clearing zone when spotted onto a fresh soft agar overlay seeded with the same strain, whereas a bacteriocin will not produce a clearing zone when transferred to a fresh soft agar lawn, owing to the dilution of the bacteriocin. PMID:28117830

  3. Investigation of dental alginate and agar impression materials as a brain simulant for ballistic testing.

    PubMed

    Falland-Cheung, Lisa; Piccione, Neil; Zhao, Tianqi; Lazarjan, Milad Soltanipour; Hanlin, Suzanne; Jermy, Mark; Waddell, J Neil

    2016-06-01

    Routine forensic research into in vitro skin/skull/brain ballistic blood backspatter behavior has traditionally used gelatin at a 1:10 Water:Powder (W:P) ratio by volume as a brain simulant. A limitation of gelatin is its high elasticity compared to brain tissue. Therefore this study investigated the use of dental alginate and agar impression materials as a brain simulant for ballistic testing. Fresh deer brain, alginate (W:P ratio 91.5:8.5) and agar (W:P ratio 81:19) specimens (n=10) (11×22×33mm) were placed in transparent Perspex boxes of the same internal dimensions prior to shooting with a 0.22inch caliber high velocity air gun. Quantitative analysis to establish kinetic energy loss, vertical displacement elastic behavior and qualitative analysis to establish elasticity behavior was done via high-speed camera footage (SA5, Photron, Japan) using Photron Fastcam Viewer software (Version 3.5.1, Photron, Japan) and visual observation. Damage mechanisms and behavior were qualitatively established by observation of the materials during and after shooting. The qualitative analysis found that of the two simulant materials tested, agar behaved more like brain in terms of damage and showed similar mechanical response to brain during the passage of the projectile, in terms of energy absorption and vertical velocity displacement. In conclusion agar showed a mechanical and subsequent damage response that was similar to brain compared to alginate.

  4. Use of Mueller-Hinton broth and agar in the germ tube test.

    PubMed

    Mattei, Antonella Souza; Alves, Sydney Hartz; Severo, Cecília Bittencourt; Guazzelli, Luciana da Silva; Oliveira, Flávio de Mattos; Severo, Luiz Carlos

    2014-01-01

    Candida albicans is often isolated from clinical samples, thus its presumptive differentiation from other species of the same genus can be based on its ability to form the germ tube in human serum. Nevertheless, there are two other species that share this characteristic: C. dubliniensis and C. africana. The aim of this study was to compare four different substrates to perform the germ tube (GT) test. The Candida spp. isolates were identified using a manual system (135 C. albicans, 24 C. tropicalis and one C. dubliniensis). The germ tube test was performed with fresh, previously frozen serum and Mueller-Hinton (MH) broth and agar. GT was observed in 96% (130/136) of the isolates through the fresh serum technique, 94% (128/136) through previously frozen serum, 92% (125/136) in MH agar, and 90% (122/136) in MH broth. The sensitivity of each test was higher than 90%, with 100% specificity. Both the MH agar and broth were able to identify the true positives, and false positives were not found. However, some C. albicans isolates were not identified. MH agar and broth may be used in laboratory for the rapid presumptive identification of C. albicans, as an alternative method for germ tube test.

  5. Alternative plasticizers for the production of thermo-compressed agar films

    Technology Transfer Automated Retrieval System (TEKTRAN)

    One percent agar (% wt) was dissolved in the deep eutectic solvent (DES), (2-hydroxyethyl) trimethylammonium chloride/urea at a 1:2 molar ratio, and successfully Electrospun into nanofibers. An existing electrospinning set-up, operated at 50 deg C, was adapted for use with an ethanol bath to collect...

  6. Use of bile-esculin agar for rapid differentiation of Enterobacteriaceae.

    PubMed Central

    Lindell, S S; Quinn, P

    1975-01-01

    Bile-esculin agar has been used for several years for the presumptive identification of group D streptococci. All members of the Enterobacteriaceae family will also grow on this medium, but only certain ones can hydrolyze esculin to 6,7-dihydroxycoumarin, which reacts with iron to produce a characteristic blackening of the medium. One thousand and six cultures from clinical specimens representing 20 genera were isolated and identified. Heavy inocula from fresh pure culture isolates on heart infusion agar were placed on bile-esculin agar slants and incubated at 35 C. The slants were examined at 4 h and again at 18 h for esculin hydrolysis. Shigella, Salmonella, Arizona, Proteus mirabilis, Proteus morganii, Providencia alcalifaciens, and Providencia stuartii all produced negative results. Klebsiella pneumoniae, Enterobacter aerogenes, Serratia marcescens, and Serratia rubidaea produced a positive reaction in 4 h. The other remaining eight genera exhibited varying results. The use of this medium in conjunction with triple sugar iron-lysine iron agar has been of great value in differentiating the Klebsiella-Enterobacter-Serratia group from other Enterobacteriaceae. PMID:1176613

  7. Analysis of beta-hemolysis in human blood agars by Streptococcus pyogenes.

    PubMed

    Zomorodian, Kamiar; Rahimi, Mohammad Javad; Safaei, Akbar; Bazargani, Abdollah; Motamadi, Marjan; Kharazi, Mahboobeh; Mostaghni, Setareh; Pakshir, Keyvan; Ghaedi, Hamid; Afsarian, Mohammad Hossein

    2011-06-01

    The aim of the study was to assess the reliability of human blood agar media (HuBA) in identifying Streptococcus pyogenes by hemolysis analysis. We analyze several factors that might affect the accuracy of HuBA media for microbial analysis, including incubation time, blood group, Rh factor and presence of antistreptolysin-o.

  8. Rapid diagnosis of acanthamoeba keratitis using non-nutrient agar with a lawn of E. coli

    PubMed Central

    2013-01-01

    Background A patient presented with a corneal foreign body in his only eye. He was treated with prophylactic antibiotics and sent home, but deteriorated. Findings He returned to the hospital 5 days later, and on slit-lamp examination, there was ciliary injection, corneal oedema and a 1 mm × 1 mm corneal abscess with mild anterior uveitis. Corneal scrapings were taken for culture on a non-nutrient agar with a lawn of Escherichia coli, on chocolate agar and on blood agar. He was treated with fortified gentamicin and cefazolin drops. He improved and was discharged 4 days after admission. On day 5, the culture results showed acanthamoeba. He was brought back to the hospital and treated with hourly chlorhexidine drops, ofloxacin six times daily and neomycin/dexamethasone drops once daily. On day 7, he was discharged to continue treatment at home, at which time his visual acuity in that eye was 6/9, and slit-lamp examination showed punctate keratitis and a stromal opacity with mild peripheral infiltration. Conclusions Culture on non-nutrient agar with a lawn of E. coli is a rapid, reliable and less invasive alternative to corneal biopsy for the diagnosis of acanthamoeba infection. We suggest using this method where acanthamoeba is suspected. Owing to the risk of corneal abscess, orthokeratology should be avoided in an amblyopic patient or an only eye. Acanthamoeba infection may be masked by other eye diseases. PMID:23514313

  9. In vitro growth of bioactive nanostructured apatites via agar-gelatin hybrid hydrogel.

    PubMed

    Deng, Yi; Zhao, Xianghui; Zhou, Yongsheng; Zhu, Peizhi; Zhang, Li; Wei, Shicheng

    2013-12-01

    Biomimetic synthesis of bone-like carbonated apatite with good biocompatibility is a promising strategy for the development of novel biomaterials for bone engineering applications. Most research efforts have been focused on only protein-based or only polysaccharide-based template for synthesis of apatite minerals. To understand the cooperative roles of gelatin and polysaccharide playing in the biomineralization, agar hydrogel, gelatin and agar-gelatin hybrid hydrogel were respectively introduced as mineralization matrix for the in vitro growth of apatite in the study. It was shown that bundle-like carbonated apatite was successfully prepared in agar-gelatin hybrid hydrogel for the first time, through the interaction between apatite and matrix macromolecule under physiological temperature. Moreover, the in vitro biocompatibility of the prepared nanostructured apatite crystals was investigated using CCK-8 assay and alkaline phosphatase activity of osteoblast-like MC3T3-E1. Compared with HA synthesized by traditional method, the obtained apatite in agar-gelatin hybrid hydrogel could provide significantly higher cell viability and alkaline phosphatase activity. Through the study, we could better understand the role of gelatin and polysaccharide in bone formation process, and the product is a promising candidate to be used in bone tissue engineering.

  10. Applying Agar's Concept of "Languaculture" to Explain Asian Students' Experiences in the Australian Tertiary Context

    ERIC Educational Resources Information Center

    Norris, Lindy; Tsedendamba, Nara

    2015-01-01

    This paper reports part of a broader qualitative case study of Asian students "translation" (Agar, 2006) to study in an Australian university. The paper is concerned with the experiences of eight participants and their involvement in a training programme in the use of language learning strategies (LLS) to support their engagement with…

  11. The relationship between growth in agar, karyotype and prognosis in acute leukaemia.

    PubMed

    Gustavsson, A; Mitelman, F; Olofsson, T; Olsson, I

    1984-04-01

    The growth pattern in agar culture and the karyotype of bone marrow cells were studied in 79 patients with untreated acute non-lymphocytic leukaemia (ANLL). Results were divided into the following groups: (A) colony and cluster formation; (B) growth of less than 600 small clusters per 10(5) cells; (C) growth of more than 600 small clusters; (D) no growth in agar. Cytogenetically, the patients were divided into 3 categories: NN, normal metaphases only; AN, both abnormal and normal metaphases and AA, abnormal metaphases only. An association was seen between growth pattern and karyotype: the majority of NN patients (33/37) belonged to group (A + B) while in group (C + D) 20/24 patients were AN or AA. 37 patients were prognostically evaluable. The growth pattern in agar but not the cytogenetic pattern had prognostic implications. 25 patients with acute lymphocytic leukaemia (ALL) were also studied at diagnosis. Different growth patterns in agar had no impact on prognosis. No relationship was detected between growth pattern and karyotype in ALL.

  12. Use of bile-esculin agar for rapid differentiation of Enterobacteriaceae.

    PubMed

    Lindell, S S; Quinn, P

    1975-05-01

    Bile-esculin agar has been used for several years for the presumptive identification of group D streptococci. All members of the Enterobacteriaceae family will also grow on this medium, but only certain ones can hydrolyze esculin to 6,7-dihydroxycoumarin, which reacts with iron to produce a characteristic blackening of the medium. One thousand and six cultures from clinical specimens representing 20 genera were isolated and identified. Heavy inocula from fresh pure culture isolates on heart infusion agar were placed on bile-esculin agar slants and incubated at 35 C. The slants were examined at 4 h and again at 18 h for esculin hydrolysis. Shigella, Salmonella, Arizona, Proteus mirabilis, Proteus morganii, Providencia alcalifaciens, and Providencia stuartii all produced negative results. Klebsiella pneumoniae, Enterobacter aerogenes, Serratia marcescens, and Serratia rubidaea produced a positive reaction in 4 h. The other remaining eight genera exhibited varying results. The use of this medium in conjunction with triple sugar iron-lysine iron agar has been of great value in differentiating the Klebsiella-Enterobacter-Serratia group from other Enterobacteriaceae.

  13. Comparison of the antibacterial activity of chelating agents using the agar diffusion method

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The agar diffusion assay was used to examine antibacterial activity of 2 metal chelators. Concentrations of 0 to 40 mM of ethylenediaminetetraacetic acid (EDTA) and ethylenediamine-N,N’-disuccinic acid (EDDS) were prepared in 1.0 M potassium hydroxide (KOH). The pH of the solutions was adjusted to 1...

  14. Mercury in fruiting bodies of Fly Agaric Amanita muscaria (L.: Fr.) Pers. collected from Poland

    NASA Astrophysics Data System (ADS)

    Falandysz, J.; Lipka, K.

    2003-05-01

    Total mercury concentrations were determined in the fruiting bodies of Fly Agaric Amanita muscaria (L.: FL) Pers. and underlying soil substrate collected from several sites in Poland in 1993-2000 to evaluate mercury status as contaminant and bioindicating features of this species. The samples were collected from the spatially distant sites such as: Zaborski Landscape Park, Mierzeja Wiślana Landscape Park, Wdzydzki Landscape Park, Borecka Forest, Tucholskie Forest, Wieluńska Upland, the communities of Gubin, Manowo, Lubiana and Morag. Total mercury content of caps and stalks of Fly agaric varied widely depending on the sites examined. The range of the mean mercury concentrations for all 17 sites was between 96±10 and 1900±1400 ng/g dry wt for the caps and between 6l±32 and 920±760 ng/g dry wt for the stalks, while between 4.4±3.1 and 150±20 ng/g were noted for soil substrate samples from 9 sites examined. Fly agaric independently of the site examined showed relatively good capacity to accumulate total mercury and BCF values varied between 16±10 and 74±15 for the caps and between 11±8 and 42±10 for the stalks. Nevertheless, relatively high bioconcentration potential of mercury by Fly agaric seems to be specific for that species and under soil mercury concentrations noted no bioindication properties of this mushroom could be observed.

  15. Use of the Soft-agar Overlay Technique to Screen for Bacterially Produced Inhibitory Compounds.

    PubMed

    Hockett, Kevin L; Baltrus, David A

    2017-01-14

    The soft-agar overlay technique was originally developed over 70 years ago and has been widely used in several areas of microbiological research, including work with bacteriophages and bacteriocins, proteinaceous antibacterial agents. This approach is relatively inexpensive, with minimal resource requirements. This technique consists of spotting supernatant from a donor strain (potentially harboring a toxic compound(s)) onto a solidified soft agar overlay that is seeded with a bacterial test strain (potentially sensitive to the toxic compound(s)). We utilized this technique to screen a library of Pseudomonas syringae strains for intraspecific killing. By combining this approach with a precipitation step and targeted gene deletions, multiple toxic compounds produced by the same strain can be differentiated. The two antagonistic agents commonly recovered using this technique are bacteriophages and bacteriocins. These two agents can be differentiated using two simple additional tests. Performing a serial dilution on a supernatant containing bacteriophage will result in individual plaques becoming less in number with greater dilution, whereas serial dilution of a supernatant containing bacteriocin will result a clearing zone that becomes uniformly more turbid with greater dilution. Additionally, a bacteriophage will produce a clearing zone when spotted onto a fresh soft agar overlay seeded with the same strain, whereas a bacteriocin will not produce a clearing zone when transferred to a fresh soft agar lawn, owing to the dilution of the bacteriocin.

  16. Agar media that indicate acid production from sorbitol by oral microorganisms.

    PubMed Central

    Kalfas, S; Edwardsson, S

    1985-01-01

    Two varieties of agar medium (Trypticase [BBL Microbiology Systems]-serum-sorbitol-bromcresol purple agar [TSSB] and Trypticase-blood-sorbitol-CaCO3 agar [TBSCa]) indicating microbial acid production from sorbitol were tested. The media were devised for use in studies on the prevalence of sorbitol-fermenting human oral microorganisms incubated in an anaerobic or microaerophilic atmosphere containing 5 to 6% CO2. TSSB contains bromcresol purple as the pH indicator and NaHCO3 as the main buffering salt. TBSCa contains CaCO3 as both the buffering salt and the indicator of acid production. The growth yield of pure cultures of oral microorganisms on TBSCa was shown to equal that on blood agar incubated under similar conditions. TSSB inhibited the growth of several bacteria to various extents. The recovery of sorbitol-fermenting microorganisms from oral specimens was the greatest when the specimens were assayed with TBSCa. The poorer results obtained with TSSB were mainly due to the decoloration of the pH indicator in this medium and the presence of greater numbers of sorbitol false-positive colonies. Images PMID:2933424

  17. Influence of different Mueller-Hinton agars and media age on Etest susceptibility testing of tigecycline.

    PubMed

    Tan, Thean Yen; Ng, Lily Siew Yong; Chen, Dorene Mei Mei

    2010-09-01

    This study investigated the effect of different Mueller-Hinton agars and media age on tigecycline MICs, obtained by Etest. Variations in MIC values on different Mueller-Hinton were noted, which may result in changes in categoric susceptibility. The use of stored Mueller-Hinton media had minimal effect on MIC values.

  18. Practical agar-based disk potentiation test for detection of fosfomycin-nonsusceptible Escherichia coli clinical isolates producing glutathione S-transferases.

    PubMed

    Nakamura, Genki; Wachino, Jun-Ichi; Sato, Natsumi; Kimura, Kouji; Yamada, Keiko; Jin, Wanchun; Shibayama, Keigo; Yagi, Tetsuya; Kawamura, Kumiko; Arakawa, Yoshichika

    2014-09-01

    The number of reports concerning Escherichia coli clinical isolates that produce glutathione S-transferases responsible for fosfomycin resistance (FR-GSTs) has been increasing. We have developed a disk-based potentiation test in which FR-GST producers expand the growth inhibition zone around a Kirby-Bauer disk containing fosfomycin in combination with sodium phosphonoformate (PPF). PPF, an analog of fosfomycin, is a transition-state inhibitor of FosA(PA), a type of FR-GST from Pseudomonas aeruginosa. Considering its mechanism of action, PPF was expected to inhibit a variety of FR-GSTs. In the presence of PPF, zone enlargement around the disk containing fosfomycin was observed for FosA3-, FosA4-, and FosC2-producing E. coli clinical isolates. Moreover, the growth inhibition zone was remarkably enlarged when the Mueller-Hinton (MH) agar plate contained 25 μg/ml glucose-6-phosphate (G6P). When we retrospectively tested 12 fosfomycin-resistant (MIC, ≥256 μg/ml) E. coli clinical isolates from our hospital with the potentiation test, 6 FR-GST producers were positive phenotypically by potentiation disk and were positive for FR-GST genes: 5 harbored fosA3 and 1 harbored fosA4. To identify the production of FR-GSTs, we set the provisional cutoff value, 5-mm enlargement, by adding PPF to a fosfomycin disk on the MH agar plates containing G6P. Our disk-based potentiation test reliably identifies FR-GST producers and can be performed easily; therefore, it will be advantageous in epidemiological surveys and infection control of fosfomycin-resistant bacteria in clinical settings.

  19. Corrosion test cell for bipolar plates

    DOEpatents

    Weisbrod, Kirk R.

    2002-01-01

    A corrosion test cell for evaluating corrosion resistance in fuel cell bipolar plates is described. The cell has a transparent or translucent cell body having a pair of identical cell body members that seal against opposite sides of a bipolar plate. The cell includes an anode chamber and an cathode chamber, each on opposite sides of the plate. Each chamber contains a pair of mesh platinum current collectors and a catalyst layer pressed between current collectors and the plate. Each chamber is filled with an electrolyte solution that is replenished with fluid from a much larger electrolyte reservoir. The cell includes gas inlets to each chamber for hydrogen gas and air. As the gases flow into a chamber, they pass along the platinum mesh, through the catalyst layer, and to the bipolar plate. The gas exits the chamber through passageways that provide fluid communication between the anode and cathode chambers and the reservoir, and exits the test cell through an exit port in the reservoir. The flow of gas into the cell produces a constant flow of fresh electrolyte into each chamber. Openings in each cell body is member allow electrodes to enter the cell body and contact the electrolyte in the reservoir therein. During operation, while hydrogen gas is passed into one chamber and air into the other chamber, the cell resistance is measured, which is used to evaluate the corrosion properties of the bipolar plate.

  20. Apparatus and method for explosive bonding to edge of flyer plate

    NASA Technical Reports Server (NTRS)

    Bement, Laurence J. (Inventor); Kushnick, Anne C. (Inventor)

    1991-01-01

    The invention is an apparatus and a process for the explosive joining of a flyer plate and a base plate. The apparatus consists of a flyer plate positioned over a base plate. The flyer plate has a notch containing a filler material in intimate contact with the flyer plate. An adhesive means holds a ribbon explosive partially overlapping the notch in the flyer plate. A detonating means initiates the ribbon explosive that drives the flyer plate to accomplish a high velocity, angular collision between the mating surfaces. This collision creates surface melts and effacing bonding, resulting in electron sharing linkups between the plates. An unbonded tab fractures at a base of the notch leaving a bond to an edge of the attached flyer plate.

  1. GOLD PLATING PROCESS

    DOEpatents

    Seegmiller, R.

    1957-08-01

    An improved bath is reported for plating gold on other metals. The composition of the plating bath is as follows: Gold cyanide from about 15 to about 50 grams, potassium cyanide from about 70 to about 125 grams, and sulfonated castor oil from about 0.1 to about 10 cc. The gold plate produced from this bath is smooth, semi-hard, and nonporous.

  2. Plating methods, a survey

    NASA Technical Reports Server (NTRS)

    Berkowitz, J. B.; Emerson, N. H.

    1972-01-01

    Results are presented of a comprehensive search of the literature available, much of which has been generated by the research centers of NASA and its contractors, on plating and coating methods and techniques. Methods covered included: (1) electroplating from aqueous solutions; (2) electroplating from nonaqueous solutions; (3) electroplating from fused-salt baths; (4) electroforming; (5) electroless plating, immersion plating, and mirroring; (6) electroplating from gaseous plasmas; and (7) anodized films and conversion coatings.

  3. Measuring Contact Thermal Conductances at Low Temperatures

    NASA Technical Reports Server (NTRS)

    Salerno, Louis J.; Kittel, Peter; Brooks, Walter; Spivak, Alan L.; Marks, William G., Jr.

    1987-01-01

    Instrument measures thermal conductance of pressed contacts in liquid helium. Makes measurements automatically as function of force on pairs of brass samples having various surface finishes. Developed as part of effort to determine heat-transfer characteristics of bolted joints on cryogenically cooled focal planes in infrared equipment. Cylindrical chamber hangs from cover plate in bath of liquid helium. Inside chamber rocker arm applies controlled force to samples. Upper sample made slightly wider than lower one so two samples remain in complete contact even under slight lateral misalignment.

  4. PLATES WITH OXIDE INSERTS

    DOEpatents

    West, J.M.; Schumar, J.F.

    1958-06-10

    Planar-type fuel assemblies for nuclear reactors are described, particularly those comprising fuel in the oxide form such as thoria and urania. The fuel assembly consists of a plurality of parallel spaced fuel plate mennbers having their longitudinal side edges attached to two parallel supporting side plates, thereby providing coolant flow channels between the opposite faces of adjacent fuel plates. The fuel plates are comprised of a plurality of longitudinally extending tubular sections connected by web portions, the tubular sections being filled with a plurality of pellets of the fuel material and the pellets being thermally bonded to the inside of the tubular section by lead.

  5. CALUTRON FACE PLATE

    DOEpatents

    Brobeck, W.M.

    1959-08-25

    The construction of a removable cover plate for a calutron tank is described. The plate is fabricated of a rectangular frame member to which is welded a bowed or dished plate of thin steel, reinforced with transverse stiffening ribs. When the tank is placed between the poles of a magnet, the plate may be pivoted away from the tank and magnet and is adapted to support the ion separation mechanism secured to its inner side as well as the vacuum load within the tank.

  6. Performance of chromID Clostridium difficile agar compared with BBL C. difficile selective agar for detection of C. difficile in stool specimens.

    PubMed

    Han, Sang Bong; Chang, Jiyoung; Shin, Sang Hyun; Park, Kang Gyun; Lee, Gun Dong; Park, Yong Gyu; Park, Yeon-Joon

    2014-09-01

    We evaluated the performance of a new chromogenic medium for detection of Clostridium difficile, chromID C. difficile agar (CDIF; bioMérieux, France), by comparison with BBL C. difficile Selective Agar (CDSA; Becton Dickinson and Company, USA). After heat pre-treatment (80℃, 5 min), 185 diarrheal stool samples were inoculated onto the two media types and incubated anaerobically for 24 hr and 48 hr for CDIF and for 48 hr and 72 hr for CDSA. All typical colonies on each medium were examined by Gram staining, and the gram-positive rods confirmed to contain the tpi gene by PCR were identified as C. difficile. C. difficile was recovered from 36 samples by using a combination of the two media. The sensitivity with CDIF 48 hr was highest (100%) and was significantly higher than that with CDIF 24 hr (58.3%; P<0.001), because samples with a low burden of C. difficile tended to require prolonged incubation up to 48 hr (P<0.001). The specificity of CDIF 24 hr and CDIF 48 hr (99.3% and 90.6%, respectively) was significantly higher than that of CDSA 48 hr and CDSA 72 hr (72.5% and 67.1%, respectively; P<0.001). CDIF was effective for detecting C. difficile in heat-pretreated stool specimens, thus reducing unnecessary testing for toxin production in non-C. difficile isolates and turnaround time.

  7. Effect of lignin on water vapor barrier, mechanical, and structural properties of agar/lignin composite films.

    PubMed

    Shankar, Shiv; Reddy, Jeevan Prasad; Rhim, Jong-Whan

    2015-11-01

    Biodegradable composite films were prepared using two renewable resources based biopolymers, agar and lignin alkali. The lignin was used as a reinforcing material and agar as a biopolymer matrix. The effect of lignin concentration (1, 3, 5, and 10wt%) on the performance of the composite films was studied. In addition, the mechanical, water vapor barrier, UV light barrier properties, FE-SEM, and TGA of the films were analyzed. The agar/lignin films exhibited higher mechanical and UV barrier properties along with lower water vapor permeability compared to the neat agar film. The FTIR and SEM results showed the compatibility of lignin with agar polymer. The swelling ratio and moisture content of agar/lignin composite films were decreased with increase in lignin content. The thermostability and char content of agar/lignin composite films increased with increased lignin content. The results suggested that agar/lignin films have a potential to be used as a UV barrier food packaging material for maintaining food safety and extending the shelf-life of the packaged food.

  8. Agar Sediment Test for Assessing the Suitability of Organic Waste Streams for Recovering Nutrients by the Aquatic Worm Lumbriculus variegatus

    PubMed Central

    Laarhoven, Bob; Elissen, H. J. H.; Temmink, H.; Buisman, C. J. N.

    2016-01-01

    An agar sediment test was developed to evaluate the suitability of organic waste streams from the food industry for recovering nutrients by the aquatic worm Lumbriculus variegatus (Lv). The effects of agar gel, sand, and food quantities in the sediment test on worm growth, reproduction, and water quality were studied. Agar gel addition ameliorated growth conditions by reducing food hydrolysis and altering sediment structure. Best results for combined reproduction and growth were obtained with 0.6% agar-gel (20 ml), 10 g. fine sand, 40 g. coarse sand, and 105 mg fish food (Tetramin). With agar gel, ingestion and growth is more the result of addition of food in its original quality. Final tests with secondary potato starch sludge and wheat bran demonstrated that this test is appropriate for the comparison of solid feedstuffs and suspended organic waste streams. This test method is expected to be suitable for organic waste studies using other sediment dwelling invertebrates. PMID:26937632

  9. Agar Sediment Test for Assessing the Suitability of Organic Waste Streams for Recovering Nutrients by the Aquatic Worm Lumbriculus variegatus.

    PubMed

    Laarhoven, Bob; Elissen, H J H; Temmink, H; Buisman, C J N

    2016-01-01

    An agar sediment test was developed to evaluate the suitability of organic waste streams from the food industry for recovering nutrients by the aquatic worm Lumbriculus variegatus (Lv). The effects of agar gel, sand, and food quantities in the sediment test on worm growth, reproduction, and water quality were studied. Agar gel addition ameliorated growth conditions by reducing food hydrolysis and altering sediment structure. Best results for combined reproduction and growth were obtained with 0.6% agar-gel (20 ml), 10 g. fine sand, 40 g. coarse sand, and 105 mg fish food (Tetramin). With agar gel, ingestion and growth is more the result of addition of food in its original quality. Final tests with secondary potato starch sludge and wheat bran demonstrated that this test is appropriate for the comparison of solid feedstuffs and suspended organic waste streams. This test method is expected to be suitable for organic waste studies using other sediment dwelling invertebrates.

  10. High Reynolds number oscillating contact lines

    NASA Astrophysics Data System (ADS)

    Liu, Ziyuan; Schultz, William W.; Perlin, Marc

    1999-11-01

    Stainless steel, instead of Ting and Perlin's (1995) glass, is used in vertically oscillating plate experiments for a large range of Reynolds numbers. We used the non-wetting stainless steel to minimize the static meniscus that we ignore in our analysis. Except for the different static contact angle serving as an initial condition, the dynamic features in both cases are similar. In low Reynolds number oscillation, a pinned-edge condition can appropriately describe the contact line motion. In high Reynolds number oscillation, contact-line behavior becomes nonlinear and very complicated. The periodic, non-sinusoidal motion exhibits three types of motion: stick (associated with contact angle hysteresis), partial stick, and total slip. Increasing the Reynolds number, reduces the hysteresis phenomenon that still cannot be ignored. An edge condition allowing both the static range and dynamic interface behavior uses a slip coefficient mode that varies with time, stroke amplitude and frequency by introducing additional harmonic modes. Using this edge condition, we calculate the dynamic contact angle and the contact-line position for both stick and slip motion and compare them to our experimental data. Results show that the inviscid, linearized boundary-value problem combined with our slip coefficient model provides an improved prediction of the contact-line behavior.

  11. A comparison of standard cultural methods for the detection of foodborne Salmonella species including three new chromogenic plating media.

    PubMed

    Schönenbrücher, Vanessa; Mallinson, Edward T; Bülte, Michael

    2008-03-31

    In this study the draft of the horizontal method for the detection of Salmonella species from human food and animal feed (ISO 6579:2002) was compared to the European gold standard (DIN EN 12824:1998), including the three new chromogenic plating media AES Salmonella Agar Plate (ASAP), Oxoid Salmonella Chromogen Media (OSCM) and Miller-Mallinson agar (MM). First the growth and appearance of 36 bacterial type strains (Salmonella and other 21 species) on ASAP, OSCM and MM were compared to those on the three traditional agars Brilliant Green Agar according to Edel and Kampelmacher (BGA), Xylose Lysine Deoxycholate Agar (XLD) and Xylose Lysine Tergitol 4 Agar (XLT4). Only on MM agar, did all of 36 tested type strains produce typical colonies, especially strains of S. Senftenberg, Salmonella arizonae, S. Dublin and S. Derby. Artificial inoculation experiments using raw pork ground meat (n=92) were subsequently conducted. A shortened incubation time of 24 h in RVS broth yielded a Salmonella species recovery of 100% from spiked meat samples. Finally, 286 naturally contaminated raw porcine and bovine minced meat samples and raw poultry meat samples were investigated. Forty-three strains from a total of 39 Salmonella-positive samples were found. S. Typhimurium (n=21), with DT 104 L, DT 012 and RDNC being the most prevalent subtypes isolated. D-tartrate-positive S. Paratyphi B (n=2) and S. Saint-Paul (n=3) were also recovered. They were cultured from poultry meat and were multi-resistant against antibiotics including nalidixic acid. Rappaport Vassiliadis broth with soypeptone (RVS) yielded the highest recovery of Salmonella spp. (97,4%) compared to Tetrathionate broth with Novobiocin according to Muller and Kauffman (MKTTn, 94,9%) and Selenite Cystine broth (SC, 38,5%). However, no significant difference was obtained by comparing the ISO 6579:2002 draft to the gold standard.

  12. Blue Willow Story Plates

    ERIC Educational Resources Information Center

    Fontes, Kris

    2009-01-01

    In the December 1997 issue of "SchoolArts" is a lesson titled "Blue Willow Story Plates" by Susan Striker. In this article, the author shares how she used this lesson with her middle-school students many times over the years. Here, she describes a Blue Willow plate painting project that her students made.

  13. Earthquakes and plate tectonics

    USGS Publications Warehouse

    Spall, H.

    1977-01-01

    An explanation is to be found in plate tectonics, a concept which has revolutionized thinking in the Earth sciences in the last 10 years. The theory of plate tectonics combines many of the ideas about continental drift (originally proposed in 1912 by Alfred Wegener in Germany) and sea-floor spreading (suggested originally by Harry Hess of Princeton University). 

  14. Contact Us about Asbestos

    EPA Pesticide Factsheets

    How to contact EPA for more information on asbestos, including state and regional contacts, EPA’s Asbestos Abatement/Management Ombudsman and the Toxic Substances Control Act (TSCA) Assistance Information Service (TSCA Hotline).

  15. Colored Contact Lens Dangers

    MedlinePlus

    ... Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Sep. 26, 2013 It ... the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In One Eye By ...

  16. Turbine vane plate assembly

    DOEpatents

    Schiavo Jr., Anthony L.

    2006-01-10

    A turbine vane assembly includes a turbine vane having first and second shrouds with an elongated airfoil extending between. Each end of the airfoil transitions into a shroud at a respective junction. Each of the shrouds has a plurality of cooling passages, and the airfoil has a plurality of cooling passages extending between the first and second shrouds. A substantially flat inner plate and an outer plate are coupled to each of the first and second shrouds so as to form inner and outer plenums. Each inner plenum is defined between at least the junction and the substantially flat inner plate; each outer plenum is defined between at least the substantially flat inner plate and the outer plate. Each inner plenum is in fluid communication with a respective outer plenum through at least one of the cooling passages in the respective shroud.

  17. Crystallization of brushite from EDTA-chelated calcium in agar gels

    NASA Astrophysics Data System (ADS)

    Plovnick, Ross H.

    1991-10-01

    Brushite (dicalcium phosphate dihydrate, CaHPO 4·2H 2O, DCPD) has been crystallized from ethylenediaminetetraacetic acid (EDTA)-chelated calcium in agar gels at initial pH 4.5-6.4 and Ca/P molar ratio above about 0.8. White, spherular crystalline DCPD aggregates up to 1 mm in diameter grew in 8-10 weeks. Liesegang ring were occassionally observed at initial gel pH 5 and Ca/P molar ratio near 1. Crystals were characterized by X-ray diffraction analysis, scanning electron microscopy, and infrared absorption spectroscopy. Brushite crystals were also grown in agar gels with either unchelated Ca initially present in the gels and EDTA in overlying solutions, or EDTA initially present in the gels and unchelated Ca in overlying solutions. These crystals grew as 2-3 mm aggregates mainly within 1-3 cm of the gel-solution interface.

  18. [Physical properties of the agar of Gracilariopsis tenuifrons (Gracilariacea) from Sucre, Venezuela].

    PubMed

    Zecchinel, E; Brito, L; Lárez, G

    2000-12-01

    The yield, gel strength, gelling and melting temperatures of Gracilariopsis tenuifrons agar from Guayacán, Araya Peninsula, Sucre State, Venezuela were determined. Yield values with and without alkali treatment ranged from 23.22 to 39.57% and from 16.29 to 22.42% respectively, while gel strength with alkali treatment fluctuated betwen 699.31 and 1231.69 g/cm2 and without treatment varied from 278.0 to 691.06 g/cm2. Gelling and melting temperatures were in the range reported for other agarophytes. Considering gel strength, the agar quality of G. tenuifrons was higher than in other species and its exploitation in economically feasible.

  19. Modification of the Congo red agar method to detect biofilm production by Staphylococcus epidermidis.

    PubMed

    Kaiser, Thaís Dias Lemos; Pereira, Eliezer Menezes; Dos Santos, Kátia Regina Netto; Maciel, Ethel Leonor Noia; Schuenck, Ricardo Pinto; Nunes, Ana Paula Ferreira

    2013-03-01

    Staphylococcus epidermidis in immunocompromised patients can cause bacteremia related to the use of catheter due to biofilm production. There are different phenotypic methods to detect biofilm formation. One method is based on culture in brain heart infusion agar (BHIA) containing sucrose and red Congo dye (original Congo red agar). Our group created a new CRA formula and we have confirmed its capacity to detect biofilm production in 210 S. epidermidis strains, including 76 (36.2%) icaAB gene-positive strains. Other parameters were also evaluated. The new CRA formula that gave the best results was BHIA with sucrose (5%), Congo red (0.08%), NaCl (1.5%), glucose (2%), and vancomycin (0.5 mg/mL) (vancomycin-modified CRA-CRAmod). The CRAmod plus vancomycin may be a promising tool and can help to determine the real participation of S. epidermidis in the infectious process.

  20. Tentative inhibition zone criteria (Bauer-Kirby agar disk diffusion method) for rifampin against staphylococci.

    PubMed

    Traub, W H; Spohr, M; Bauer, D

    1987-01-01

    Two of 359 (0.6%) clinical isolates of Staphylococcus aureus and 12 of 218 (5.5%) clinical isolates of coagulase-negative staphylococci were resistant or of intermediate susceptibility against rifampin as based on minimal inhibitory concentration (MIC) breakpoints obtained with the agar dilution method: MIC greater than or equal to 2 micrograms/ml = resistant; MIC 0.25-1 microgram/ml = intermediate susceptible; MIC less than 0.125 microgram/ml = susceptible. The following inhibition zone criteria with 2 micrograms rifampin disks were proposed for staphylococcal isolates utilizing the Bauer-Kirby agar disk diffusion test: diameter of inhibition zones less than or equal to 13 mm = resistant; diameter 14-21 mm = intermediate susceptible; diameter greater than or equal to 22 mm = susceptible.

  1. Electrochemical Device Comprising Composite Bipolar Plate and Method of Using the Same

    NASA Technical Reports Server (NTRS)

    Mittelsteadt, Cortney K. (Inventor); Braff, William A. (Inventor)

    2013-01-01

    An electrochemical device and methods of using the same. In one embodiment, the electrochemical device may be used as a fuel cell and/or as an electrolyzer and includes a membrane electrode assembly (MEA), an anodic gas diffusion medium in contact with the anode of the MEA, a cathodic gas diffusion medium in contact with the cathode, a first bipolar plate in contact with the anodic gas diffusion medium, and a second bipolar plate in contact with the cathodic gas diffusion medium. Each of the bipolar plates includes an electrically-conductive, chemically-inert, non-porous, liquid-permeable, substantially gas-impermeable membrane in contact with its respective gas diffusion medium, as well as a fluid chamber and a non-porous an electrically-conductive plate.

  2. Electrochemical Device Comprising Composite Bipolar Plate and Method of Using the Same

    NASA Technical Reports Server (NTRS)

    Mittelsteadt, Cortney K. (Inventor); Braff, William A. (Inventor)

    2017-01-01

    An electrochemical device and methods of using the same. In one embodiment, the electrochemical device may be used as a fuel cell and/or as an electrolyzer and includes a membrane electrode assembly (MEA), an anodic gas diffusion medium in contact with the anode of the MEA, a cathodic gas diffusion medium in contact with the cathode, a first bipolar plate in contact with the anodic gas diffusion medium, and a second bipolar plate in contact with the cathodic gas diffusion medium. Each of the bipolar plates includes an electrically-conductive, chemically-inert, non-porous, liquid-permeable, substantially gas-impermeable membrane in contact with its respective gas diffusion medium, as well as a fluid chamber and a non-porous an electrically-conductive plate.

  3. Microbiological analysis of debris from STS-42 IML-1 by direct plating of rinse waters

    NASA Technical Reports Server (NTRS)

    Smithers, G. A.

    1992-01-01

    Microbial analysis of air filter debris from the Spacelab International Microgravity Laboratory-1 (IML-1) mission was performed via direct plating of rinse waters on a battery of selective and nonselective nutrient agars. Microbial isolates were identified using Minitek and Biolog technologies. Twenty-four types of bacteria were recovered and classified; a similar number of fungal types was observed, but these were not identified. This procedure can provide information about the proportions of organism types present at the time of debris collection.

  4. Contact Lenses on Submarines

    DTIC Science & Technology

    2014-09-26

    NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY SUBMARINE BASE, GROTON, CONN. REPORT NUMBER 1048 CONTACT LENSES ON SUBMARINES... CONTACT LENSES ON SUBMARINES by James F. Socks, CDR, MSC, USN NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY REPORT NUMBER 1048 NAVAL MEDICAL RESEARCH...DRSCHLAB Approved for public release; distribution unlimited SUMMARY PAGE PROBLEM To determine the feasibility of wearing contact lenses aboard

  5. Glasses and Contact Lenses

    MedlinePlus

    ... dientes Video: Getting an X-ray Glasses and Contact Lenses KidsHealth > For Kids > Glasses and Contact Lenses Print A A A What's in this ... together the way they should. But eyeglasses or contact lenses, also called corrective lenses, can help most ...

  6. Rapid Isolation and Susceptibility Testing of Leptospira spp. Using a New Solid Medium, LVW Agar

    PubMed Central

    Wuthiekanun, Vanaporn; Amornchai, Premjit; Paris, Daniel H.; Langla, Sayan; Thaipadunpanit, Janjira; Chierakul, Wirongrong; Smythe, Lee D.; White, Nicholas J.; Day, Nicholas P. J.; Peacock, Sharon J.

    2013-01-01

    Pathogenic Leptospira spp., the causative agents of leptospirosis, are slow-growing Gram-negative spirochetes. Isolation of Leptospira from clinical samples and testing of antimicrobial susceptibility are difficult and time-consuming. Here, we describe the development of a new solid medium that facilitates more-rapid growth of Leptospira spp. and the use of this medium to evaluate the Etest's performance in determining antimicrobial MICs to drugs in common use for leptospirosis. The medium was developed by evaluating the effects of numerous factors on the growth rate of Leptospira interrogans strain NR-20157. These included the type of base agar, the concentration of rabbit serum (RS), and the concentration and duration of CO2 incubation during the initial period of culture. The highest growth rate of NR-20157 was achieved using a Noble agar base supplemented with 10% RS (named LVW agar), with an initial incubation at 30°C in 5% CO2 for 2 days prior to continuous culture in air at 30°C. These conditions were used to develop the Etest for three species, L. interrogans (NR-20161), L. kirschnerii (NR-20327), and L. borgpetersenii (NR-20151). The MICs were read on day 7 for all samples. The Etest was then performed on 109 isolates of pathogenic Leptospira spp. The MIC90 values for penicillin G, doxycycline, cefotaxime, ceftriaxone, and chloramphenicol were 0.64 units/ml and 0.19, 0.047, 0.5, and 2 μg/ml, respectively. The use of LVW agar, which enables rapid growth, isolation of single colonies, and simple antimicrobial susceptibility testing for Leptospira spp., provides an opportunity for new areas of fundamental and applied research. PMID:23114772

  7. Draft genome of agar-degrading marine bacterium Gilvimarinus agarilyticus JEA5.

    PubMed

    Lee, Youngdeuk; Lee, Su-Jin; Park, Gun-Hoo; Heo, Soo-Jin; Umasuthan, Navaneethaiyer; Kang, Do-Hyung; Oh, Chulhong

    2015-06-01

    Gilvimarinus agarilyticus JEA5, which effectively degrades agar, was isolated from the seawater of Jeju Island, Republic of Korea. Here, we report the draft genome sequence of G. agarilyticus JEA5 with a total genome size of 4,179,438bp from 2 scaffolds (21 contigs) with 53.15% G+C content. Various polysaccharidases including 11 predicted agarases were observed from the draft genome of G. agarilyticus JEA5.

  8. How do microorganisms influence trace element uptake by plants? Screening in an agar model rhizosphere.

    NASA Astrophysics Data System (ADS)

    Marchetti, M.; Robinson, B. H.; Evangelou, M. W. H.; Vachey, A.; Schwitzguebel, J. P.; Bernier-Latmani, R.; Schulin, R.

    2009-04-01

    Trace elements (TE) are essential for humans and plants, but they may be toxic if their concentration is too high. For this reason, the management of TE in soils is very important. In some cases it may be necessary to increase the uptake of nutrients or TE by plants, for example in a biofortification perspective. Conversely, in some other cases TE uptake by plants should be decreased, for instance to avoid heavy metals entering the food chain via edible crops. Microorganisms living in the rhizosphere affect trace element (TE) uptake by plants. However, due to the complexity of this space and the variety of microorganisms that occur there, it is difficult to isolate the effect of any particular strain. To overcome this hurdle, we developed a system in which we grew plants under sterile conditions in agar and inoculated their rhizosphere with a single, well-defined microbial strain. For many years, agar has been used as a growth substrate for microorganisms and plant tissues. It is cheap, easy to use, and can be autoclaved to ensure its sterility. Because of its widespread use, an experiment conducted using this substrate can be reproduced under the same conditions in any laboratory. In contrast to soil, there is little interaction between the trace elements and the agar matrix. There are many studies investigating the influence of microorganisms on TE uptake by plants. However, so far only a small variety of microorganisms has been tested on few plant species. Therefore, the first objective of our research was to develop a method to rapidly screen a large variety of microorganisms on various plant species. Once this goal was achieved, we sought to study the effect of single, well-defined microbial strains on TE uptake by sunflower and wheat. The substrate for plants growth was a 10% agar solution prepared with modified Hoagland's solution and a TE solution containing 1 mg/kg Pb and molar equivalents of Cu, Ni and Zn. The agar solution was autoclaved and poured into

  9. Ultrasound induced bubble clusters and tunnels in tissue-mimicking agar phantoms

    NASA Astrophysics Data System (ADS)

    Movahed, Pooya; Kreider, Wayne; Maxwell, Adam D.; Bailey, Michael R.; Freund, Jonathan B.

    2016-11-01

    Soft tissue fractionation induced by acoustic cavitation is desired for non-invasive tissue removal in histotripsy, while being a potential injury mechanism in other therapeutic ultrasound treatments such as lithotripsy. In this work, we investigate the formation of bubble clusters and tunnels in tissue-mimicking agar phantoms by focused ultrasound bursts to inform a class of damage models. Agar phantoms of different stiffness were subjected to a series of multi-cycle ultrasound bursts, using a burst wave lithotripsy (BWL) protocol, and simultaneously imaged at 200 frames per second (1 image per ultrasound burst). Some bubbles become visible in images ( 200 microns) due to the negative pressure ( 7.5 MPa) in the initial bursts, and the number of visible bubbles increases continuously during the subsequent bursts. A Rayleigh-Plesset-type bubble dynamics model, which accounts for viscoelastic confinement of agar gels, is developed. Material fatigue leading to eventual irreversible fracture-like failure in this model is proposed to explain the key observations. In addition to isolated, approximately spherical bubbles, long tunnel-like features are observed, which are seemingly lines of joined bubbles along a possible fracture or defect. The geometry of these tunnel-like features is quantified, and a physical explanation for tunnel formation is proposed in terms of bubble expansion and unstable collapse. This work was supported by NIH NIDDK Grant P01-DK043881.

  10. A supplemented soft agar chemotaxis assay demonstrates the Helicobacter pylori chemotactic response to zinc and nickel

    PubMed Central

    Sanders, Lisa; Andermann, Tessa M.

    2013-01-01

    Directed motility, or chemotaxis, is required for Helicobacter pylori to establish infection in the stomach, although the full repertoire of this bacterium’s chemotactic responses is not yet known. Here we report that H. pylori responds to zinc as an attractant and nickel as a repellent. To reach this conclusion, we employed both a temporal chemotaxis assay based on bacterial reversals and a supplemented soft agar spatial assay. We refined the temporal assay using a previously described chemorepellent, acid, and found that H. pylori requires rich media with serum to maintain optimal swimming motility. Surprisingly, we found that some strains respond to acid as an attractant, and that the TlpC chemoreceptor correlated with whether acid was sensed as an attractant or repellent. Using this same assay, we detected weak repellent responses to nickel and copper, and a varied response to zinc. We thus developed an alternative spatial chemotactic assay called the supplemented soft agar assay, which utilizes soft agar medium supplemented with the test compound. With Escherichia coli, the attractant serine slowed overall bacterial migration, while the repellent nickel increased the speed of overall migration. In H. pylori we detected slowed migration with doubled tryptone media, as well as zinc, consistent with an attractant response. In contrast, nickel increased migration, consistent with repulsion. PMID:23139399

  11. Pig and Goat Blood as Substitutes for Sheep Blood in Blood-Supplemented Agar Media

    PubMed Central

    Anand, Chandar; Gordon, Rhonda; Shaw, Helene; Fonseca, Kevin; Olsen, Merle

    2000-01-01

    In many developing countries sheep and horse blood, the recommended blood supplements in bacteriological media, are not readily available, whereas pig and goat blood are. Therefore, this study examined the use of pig and goat blood as potential substitutes for sheep blood in blood-supplemented bacteriologic media commonly used in clinical microbiology laboratories. In general, the growth characteristics and colony morphologies of a wide range of aerobic and anaerobic bacteria and Candida albicans were similar on media containing pig, goat, and sheep blood, although differences were found. Enterococcus sp. uniformly produced alpha-hemolysis when incubated in CO2, but in anaerobic conditions the hemolysis varied. In contrast, beta-hemolytic streptococci produced identical hemolytic reactions on all three media. Synergistic hemolysis was not observed on pig blood agar in the CAMP test nor on goat blood agar in the reverse CAMP test. The preparation of chocolate agar (heated) with pig blood required heating to a higher temperature than with sheep or goat blood to yield suitable growth of Haemophilus species. In general, we conclude that pig and goat blood are suitable alternatives to sheep blood for use in bacteriological media in settings where sheep and horse blood are not readily available. PMID:10655351

  12. Pig and goat blood as substitutes for sheep blood in blood-supplemented agar media.

    PubMed

    Anand, C; Gordon, R; Shaw, H; Fonseca, K; Olsen, M

    2000-02-01

    In many developing countries sheep and horse blood, the recommended blood supplements in bacteriological media, are not readily available, whereas pig and goat blood are. Therefore, this study examined the use of pig and goat blood as potential substitutes for sheep blood in blood-supplemented bacteriologic media commonly used in clinical microbiology laboratories. In general, the growth characteristics and colony morphologies of a wide range of aerobic and anaerobic bacteria and Candida albicans were similar on media containing pig, goat, and sheep blood, although differences were found. Enterococcus sp. uniformly produced alpha-hemolysis when incubated in CO(2), but in anaerobic conditions the hemolysis varied. In contrast, beta-hemolytic streptococci produced identical hemolytic reactions on all three media. Synergistic hemolysis was not observed on pig blood agar in the CAMP test nor on goat blood agar in the reverse CAMP test. The preparation of chocolate agar (heated) with pig blood required heating to a higher temperature than with sheep or goat blood to yield suitable growth of Haemophilus species. In general, we conclude that pig and goat blood are suitable alternatives to sheep blood for use in bacteriological media in settings where sheep and horse blood are not readily available.

  13. Isolation and characterization of agar-degrading endophytic bacteria from plants.

    PubMed

    Song, Tao; Zhang, Weijia; Wei, Congchong; Jiang, Tengfei; Xu, Hui; Cao, Yi; Cao, Yu; Qiao, Dairong

    2015-02-01

    Agar is a polysaccharide extracted from the cell walls of some macro-algaes. Among the reported agarases, most of them come from marine environment. In order to better understand different sources of agarases, it is important to search new non-marine native ones. In this study, seven agar-degrading bacteria were first isolated from the tissues of plants, belonging to three genera, i.e., Paenibacillus sp., Pseudomonas sp., and Klebsiella sp. Among them, the genus Klebsiella was first reported to have agarolytic ability and the genus Pseudomonas was first isolated from non-marine environment with agarase activity. Besides, seven strains were characterized by investigating the growth and agarase production in the presence of various polysaccharides. The results showed that they could grow on several polysaccharides such as araban, carrageenan, chitin, starch, and xylan. Besides, they could also produce agarase in the presence of different polysaccharides other than agar. Extracellular agarases from seven strains were further analyzed by SDS-PAGE combined with activity staining and estimated to be 75 kDa which has great difference from most reported agarases.

  14. Rotary sequencing valve with flexible port plate

    DOEpatents

    Wagner, Glenn Paul

    2005-05-10

    Rotary sequencing valve comprising a rotor having a rotor face rotatable about an axis perpendicular to the rotor face, wherein the rotor face has a plurality of openings, one or more of which are disposed at a selected radial distance from the axis, and wherein the rotor includes at least one passage connecting at least one pair of the plurality of openings. The valve includes a flexible port plate having a first side and a second side, wherein the first side faces the rotor and engages the rotor such that the flexible port plate can be rotated coaxially by the rotor and can move axially with respect to the rotor, wherein the flexible port plate has a plurality of ports between the first and second sides, which ports are aligned with the openings in the rotor face. The valve also includes a stator having a stator face disposed coaxially with the rotor and the flexible port plate, wherein the second side of the flexible port plate is in sealable, slidable rotary contact with the stator face, wherein the stator face has a plurality of openings, some of which are disposed at the selected radial distance from the axis, and wherein the plurality of openings extend as passages through the stator. The valve may be used in pressure or temperature swing adsorption systems.

  15. Effect of Curvature on the Impact Damage Characteristics and Residual Strength of Composite Plates

    NASA Technical Reports Server (NTRS)

    Ambur, Damodar R.; Starnes, James H., Jr.

    1998-01-01

    The results of a study of the response and failure characteristics of thin, cylindrically curved, composite plates subjected to low-speed impact damage are presented. The results indicate that the plate radius and the plate thickness are important structural parameters that influence the nonlinear response of a plate for a given amount of impact energy. Analytical and experimental contact-force results are compared for several plates and the results correlate well. The impact-energy levels required to cause damage initiation and barely visible impact damage are a function of the plate radius for a given plate thickness. The impact-energy levels required to initiate impact damage for plates with a certain range of radii are greater than plates with other radii. The contact-force results corresponding to these impact-energy levels follow a similar trend. Residual strength results for plates with barely visible impact damage suggest that the compression-after-impact residual strength is also a function of plate radius. The residual strength of impact-damaged flat plates appears to be lower than the residual strength of the corresponding cylindrically curved plates.

  16. Contact lens in keratoconus

    PubMed Central

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL. PMID:23925325

  17. Effects of radiotherapy on mandibular reconstruction plates

    SciTech Connect

    Castillo, M.H.; Button, T.M.; Doerr, R.; Homs, M.I.; Pruett, C.W.; Pearce, J.I.

    1988-10-01

    The radiation dose in the vicinity of metal mandibular implants was measured using lithium fluoride (TLD-100) thermoluminescent dosimeters. Dosimeters were positioned in contact with Vitallium and stainless steel (AO) reconstruction plates. Simple transmission was measured with a solid state detector removed from the implant at a depth of 2.5 cm in a polystyrene phantom. The measurements were made for a 6 mV photon beam from a linear accelerator. At points in front of, but in contact with the metal implants, the dose was greater by 23 percent for Vitallium and 17 percent for stainless steel than that with no implant. At contact behind the implant, the dose was reduced considerably: 14 percent for Vitallium and 13 percent for stainless steel. At remote points behind the implant, the dose was reduced due to attenuation.

  18. Earthquakes and plate tectonics.

    USGS Publications Warehouse

    Spall, H.

    1982-01-01

    Earthquakes occur at the following three kinds of plate boundary: ocean ridges where the plates are pulled apart, margins where the plates scrape past one another, and margins where one plate is thrust under the other. Thus, we can predict the general regions on the earth's surface where we can expect large earthquakes in the future. We know that each year about 140 earthquakes of magnitude 6 or greater will occur within this area which is 10% of the earth's surface. But on a worldwide basis we cannot say with much accuracy when these events will occur. The reason is that the processes in plate tectonics have been going on for millions of years. Averaged over this interval, plate motions amount to several mm per year. But at any instant in geologic time, for example the year 1982, we do not know, exactly where we are in the worldwide cycle of strain build-up and strain release. Only by monitoring the stress and strain in small areas, for instance, the San Andreas fault, in great detail can we hope to predict when renewed activity in that part of the plate tectonics arena is likely to take place. -from Author

  19. Pixelated neutron image plates

    NASA Astrophysics Data System (ADS)

    Schlapp, M.; Conrad, H.; von Seggern, H.

    2004-09-01

    Neutron image plates (NIPs) have found widespread application as neutron detectors for single-crystal and powder diffraction, small-angle scattering and tomography. After neutron exposure, the image plate can be read out by scanning with a laser. Commercially available NIPs consist of a powder mixture of BaFBr : Eu2+ and Gd2O3 dispersed in a polymer matrix and supported by a flexible polymer sheet. Since BaFBr : Eu2+ is an excellent x-ray storage phosphor, these NIPs are particularly sensitive to ggr-radiation, which is always present as a background radiation in neutron experiments. In this work we present results on NIPs consisting of KCl : Eu2+ and LiF that were fabricated into ceramic image plates in which the alkali halides act as a self-supporting matrix without the necessity for using a polymeric binder. An advantage of this type of NIP is the significantly reduced ggr-sensitivity. However, the much lower neutron absorption cross section of LiF compared with Gd2O3 demands a thicker image plate for obtaining comparable neutron absorption. The greater thickness of the NIP inevitably leads to a loss in spatial resolution of the image plate. However, this reduction in resolution can be restricted by a novel image plate concept in which a ceramic structure with square cells (referred to as a 'honeycomb') is embedded in the NIP, resulting in a pixelated image plate. In such a NIP the read-out light is confined to the particular illuminated pixel, decoupling the spatial resolution from the optical properties of the image plate material and morphology. In this work, a comparison of experimentally determined and simulated spatial resolutions of pixelated and unstructured image plates for a fixed read-out laser intensity is presented, as well as simulations of the properties of these NIPs at higher laser powers.

  20. Evaluation of ISO 10272:2006 standard versus alternative enrichment and plating combinations for enumeration and detection of Campylobacter in chicken meat.

    PubMed

    Habib, Ihab; Uyttendaele, Mieke; De Zutter, Lieven

    2011-09-01

    In the present study, we evaluate the recommended ISO 10272:2006 versus alternative procedures for Campylobacter enumeration and enrichment in naturally contaminated chicken meat samples (n = 49). Three enrichment media were evaluated; Bolton broth, Preston broth and CampyFood broth(®) (bioMérieux SA, Marcy l'Etoile, France). In addition, three selective plating agars were compared; modified charcoal cefoperazone deoxycholate agar (mCCDA), CampyFood agar(®) (CFA; bioMérieux SA) and Brilliance CampyCount agar(®) (BCC; Oxoid, Basingstoke, England). Direct plating on CFA provided the highest number of Campylobacter positive samples (17/49); however this was not statistically different (P > 0.05) from numbers of positive samples recovered by direct plating on mCCDA (15/49) or BCC agars (14/49). Also, there was no significant difference between Campylobacter counts on the three compared media (P > 0.05). The coloured colonies of Campylobacter on CFA and BCC were easier to record and count than those on mCCDA. Enrichment of chicken meat samples in Bolton broth for 48 h and subsequent plating on CFA provided significantly higher (P < 0.05) Campylobacter detection compared to the other broth-agar combinations. Enrichment in Preston broth for 24 h followed by plating on mCCDA gave a higher number of positive samples (20/49) than 48 h enrichment in Bolton broth and plating on mCCDA (15/49). Enrichment in Bolton broth for 48 h followed by plating on CFA recovered 35% of samples below the limit for quantifications (<10 CFU/g, n = 34), as identified by direct plating on mCCDA. Compared to the current ISO method, some alternative combinations of enrichment and agar media could provide significantly better detection and enumeration of Campylobacter in chicken meat.

  1. A comparison study of the EF-18 agar/Hydrophobic Grid Membrane Filter (HGMF) method and the enzyme linked antibody (ELA)/HGMF method to the HPB standard method in the isolation of Salmonella.

    PubMed

    Warburton, D W; Arling, V; Worobec, S; Mackenzie, J; Todd, E C; Lacasse, P; Lamontagne, G; Plante, R; Shaw, S; Bowen, B

    1994-09-01

    As part of a comparative and collaborative study of rapid methods for the detection of Salmonella and the standard Health Protection Branch (HPB) method, six Federal and Provincial Laboratories compared the EF-18 agar/Hydrophobic Grid Membrane Filters (HGMF) method to the standard HPB method. Two Federal Laboratories also compared the enzyme linked antibody (ELA)/HGMF method (which is a further development of the EF-18 agar/HGMF method) to the standard method. During this study the false-negative rates ranged from 0% to 15% for the standard HPB method, from 5.88% to 43.5% for the EF-18 agar/HGMF method, and from 0% to 10.5% for the ELA/HGMF method. The EF-18 agar/HGMF method did not compare well with the standard HPB method due to the number of false-negatives. Problems with this method resulted from the inability to isolate colonies of Salmonella on the HGMF due to the small colony size, abnormal colony coloration, and overgrowth by competitors. The ELA/HGMF method, however, was shown to be comparable to the standard HPB method. The main advantages of this method are that the antibody-staining step is independent of colony coloration and carbohydrate utilization on the plating media; the ability to detect some unusual strains of Salmonella irrespective of their atypical reactions on the media; and the ELA staining can indicate the presence of Salmonella even when the HGMF is overgrown by competitors. Also, cultural confirmation can proceed simultaneously yet independently of the ELA staining procedure. The data presented here indicate that this method is worth further study.

  2. Friction pull plug welding: dual chamfered plate hole

    NASA Technical Reports Server (NTRS)

    Coletta, Edmond R. (Inventor); Cantrell, Mark A. (Inventor)

    2001-01-01

    Friction Pull Plug Welding (FPPW) is a solid state repair process for defects up to one inch in length, only requiring single sided tooling (OSL) for usage on flight hardware. Early attempts with FPPW followed the matching plug/plate geometry precedence of the successful Friction Push Plug Welding program, however no defect free welds were achieved due to substantial plug necking and plug rotational stalling. The dual chamfered hole has eliminated plug rotational stalling, both upon initial plug/plate contact and during welding. Also, the necking of the heated plug metal under a tensile heating/forging load has been eliminated through the usage of the dual chamfered plate hole.

  3. [Immunology of contact allergy].

    PubMed

    Martin, S F

    2011-10-01

    Contact allergy is a skin disease that is caused by the reaction of the immune system to low molecular weight chemicals. A hallmark of contact allergens is their chemical reactivity, which is not exhibited by toxic irritants. Covalent binding of contact allergens to or complex formation with proteins is essential for the activation of the immune system. As a consequence antigenic epitopes are formed, which are recognized by contact allergen-specific T cells. The generation of effector and memory T cells causes the high antigen specificity and the repeated antigen-specific skin reaction of contact allergy. New findings reveal that the less specific reaction of the innate immune system to contact allergens closely resembles the reaction to an infection. Therefore, contact allergy can be viewed as an immunologic misunderstanding since the skin contact with chemical allergens is interpreted as an infection. The growing understanding of the molecular and cellular pathologic mechanisms of contact allergy can aid the development of specific therapies and of in vitro alternatives to animal testing for the identification of contact allergens.

  4. Designing Assemblies Of Plates

    NASA Technical Reports Server (NTRS)

    Williams, F. W.; Kennedy, D.; Butler, R.; Aston, G.; Anderson, M. S.

    1992-01-01

    VICONOPT calculates vibrations and instabilities of assemblies of prismatic plates. Designed for efficient, accurate analysis of buckling and vibration, and for optimum design of panels of composite materials. Written in FORTRAN 77.

  5. Plate tectonics: Metamorphic myth

    NASA Astrophysics Data System (ADS)

    Korenaga, Jun

    2016-01-01

    Clear evidence for subduction-induced metamorphism, and thus the operation of plate tectonics on the ancient Earth has been lacking. Theoretical calculations indicate that we may have been looking for something that cannot exist.

  6. Violin plate modes.

    PubMed

    Gough, Colin

    2015-01-01

    As the first step toward developing a generic model for the acoustically radiating vibrational modes of the violin and related instruments, the modes of both freely supported and edge-constrained top and back plates have been investigated as functions of shape, arching height, elastic anisotropy, the f-holes and associated island area, thickness graduations, and the additional boundary constraints of the ribs, soundpost, and bass-bar present in the assembled instrument. Comsol shell structure finite element software has been used as a quasi-experimental tool, with physical and geometric properties varied smoothly, often over several orders of magnitude, allowing the development of the plate modes to be followed continuously from those of an initially square plate to those of doubly-arched, guitar-shaped, orthotropic plates and their dependence on all the above factors.

  7. Tectonic Plate Movement.

    ERIC Educational Resources Information Center

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  8. Reduction of astrometric plates

    NASA Technical Reports Server (NTRS)

    Stock, J.

    1984-01-01

    A rapid and accurate method for the reduction of comet or asteroid plates is described. Projection equations, scale length correction, rotation of coordinates, linearization, the search for additional reference stars, and the final solution are examined.

  9. What's On Your Plate?

    MedlinePlus

    ... Table of Contents What's On Your Plate? Smart Food Choices for Healthy Aging www.nia.nih.gov/health/ ... calories in" and "calories out," and making good food choices as you age. Shopping Tips See how planning ...

  10. Feynman's wobbling plate

    NASA Astrophysics Data System (ADS)

    Tuleja, Slavomir; Gazovic, Boris; Tomori, Alexander; Hanc, Jozef

    2007-03-01

    In the book Surely You Are Joking, Mr. Feynman! Richard Feynman tells a story of a Cornell cafeteria plate being tossed into the air. As the plate spun, it wobbled. Feynman noticed a relation between the two motions. He solved the motion of the plate by using the Lagrangian approach. This solution didn't satisfy him. He wanted to understand the motion of the plate by analyzing the motion of its individual particles and the forces acting on them. He was successful, but he didn't tell us how he did it. We provide an elementary explanation for the two-to-one ratio of wobble to spin frequencies, based on an analysis of the motion of the particles and the forces acting on them. We also demonstrate the power of numerical simulation and computer animation to provide insight into a physical phenomenon and guidance on how to do the analysis.

  11. Flat plate solar oven

    SciTech Connect

    Parikh, M.

    1981-01-01

    The construction of an Indian Rs. 186 (US $20.33) flat-plate solar oven is described. Detailed drawings are provided and relevant information on cooking times and temperature for different foods is given.

  12. Fractal multifiber microchannel plates

    NASA Technical Reports Server (NTRS)

    Cook, Lee M.; Feller, W. B.; Kenter, Almus T.; Chappell, Jon H.

    1992-01-01

    The construction and performance of microchannel plates (MCPs) made using fractal tiling mehtods are reviewed. MCPs with 40 mm active areas having near-perfect channel ordering were produced. These plates demonstrated electrical performance characteristics equivalent to conventionally constructed MCPs. These apparently are the first MCPs which have a sufficiently high degree of order to permit single channel addressability. Potential applications for these devices and the prospects for further development are discussed.

  13. Positive battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John R. (Inventor)

    1985-01-01

    The power characteristics of a lead acid battery are improved by incorporating a dispersion of 1 to 10% by weight of a thermodynamically stable conductivity additive, such as conductive tin oxide coated glass fibers (34) of filamentary glass wool (42) in the positive active layer (32) carried on the grid (30) of the positive plate (16). Positive plate potential must be kept high enough to prevent reduction of the tin oxide to tin by utilizing an oversized, precharged positive paste.

  14. Non-contact measurement of contact wire

    NASA Astrophysics Data System (ADS)

    Yi, Yaxing; Ye, Xuemei; Li, Zhongke; Yue, Kaiduan

    2008-12-01

    The overhead contact system is the power supply unit of the electric locomotive. This article is to introduce our newly developed method to measure the height and pull out value of the contact wire. A carema dolly which can move on railway is applied to bear the weight of the measure equipment; two linear CCD cameras are installed on the dolly symmetrically about the midline of two rails. While the dolly move along the railway, two CCD cameras grasp the image synchronously, and a computer real-time process the images, the height and pull out value can be calculate out from the images.

  15. Comparison of performance of the novel chromogenic spectra VRE agar to that of bile esculin azide and Campylobacter agars for detection of vancomycin-resistant enterococci in fecal samples.

    PubMed

    Jenkins, S G; Raskoshina, L; Schuetz, A N

    2011-11-01

    A total of 142 stool specimens were evaluated for vancomycin-resistant enterococcus (VRE). Twenty-four-hour sensitivities and specificities, respectively, were 98% and 95% for Spectra VRE chromogenic agar (Remel, Lenexa, KS), 86% and 92% for bile esculin azide with vancomycin (BEAV; Remel), and 96.5% and 92% for Campylobacter agar (CAMPY; Remel). Spectra VRE and CAMPY are significantly more sensitive at 24 h than BEAV.

  16. Wear of connector contacts exposed to relative motion

    NASA Astrophysics Data System (ADS)

    Wilk, R. A.

    Connectors play a significant role in the performance, cost, and reliability of electronic equipment. In connection with the development of the system interconnection design, a factor which is often overlooked is related to the importance of connector selection and mounting to minimize relative motion between contacts during vibration encountered in handling, transportation, and service. This motion can lead to the loss of protective coatings (gold and nickel) due to frictional wear. If this happens, fretting corrosion of the base metals may occur. The produced damage can adversely affect performance due to increased joint resistance, eventually causing intermittent contacts. The present investigation is concerned with the study of different style contacts (tuning fork, box, and circular) to determine their endurance and wear characteristics when exposed to relative motion created by vibration. All contacts investigated were fabricated from brass, beryllium copper, or phosphor bronze, and had .00127 mm minimum gold plating over .00127 mm minimum nickel plating.

  17. [Periorbital contact eczema].

    PubMed

    Worm, M; Sterry, W

    2005-11-01

    Periorbital contact eczema is most commonly the result of an allergic contact dermatitis whereas other eczematous skin diseases like atopic eczema or seborrheic eczema occur less frequently. Also, other diseases like autoimmune disorders or rosacea need to be considered. Allergic contact dermatitis is a T-cell-mediated immunological response towards ubiquitous contact allergens. Activated T-cells migrate through the vessels into the skin and produce several inflammatory mediators. Epicutaneous patch testing is an important tool for the diagnosis of contact allergy whereby the allergens are analysed in terms of their ability to induce eczematous skin reaction. Until now the short-term use of corticosteroids are is employed for the treatment of allergic contact eczema. Modern substances with an optimal therapeutic index should rather be used.

  18. Evaluation of a novel chromogenic agar medium for isolation and differentiation of vancomycin-resistant Enterococcus faecium and Enterococcus faecalis isolates.

    PubMed

    Ledeboer, Nathan A; Das, Kingshuk; Eveland, Michael; Roger-Dalbert, Céline; Mailler, Sandrine; Chatellier, Sonia; Dunne, William Michael

    2007-05-01

    The development of reliable and rapid methods for the identification of patients colonized with vancomycin-resistant enterococci (VRE) is central to the containment of this agent within a hospital environment. To this end, we evaluated a prototype chromogenic agar medium (VRE-BMX; bioMérieux, Marcy l'Etoile, France) used to recover VRE from clinical specimens. This medium can also identify isolated colonies as either vancomycin-resistant Enterococcus faecium or Enterococcus faecalis, based on distinct colony colors. We compared the performance of VRE-BMX with bile esculin azide agar supplemented with vancomycin (BEAV). For this study, 147 stool samples were plated on each test medium and examined after 24 and 48 h of incubation. At 24 h, the sensitivity and specificity of each medium were as follows: BEAV, 90.9% and 89.9%, respectively; VRE-BMX, 96.4% and 96.6%, respectively. The positive predictive values (PPV) of VRE-BMX and BEAV at 24 h were 89.8% and 80.7%, respectively. VRE-BMX provided the identification of 10 isolates of vancomycin-resistant E. faecalis and 4 isolates of vancomycin-resistant E. faecium that were not recovered by BEAV. Further, VRE-BMX was capable of identifying patients colonized with both E. faecium and E. faecalis, a feature useful for infection control purposes that is not a function of BEAV. In terms of the recovery of vancomycin-resistant E. faecium and E. faecalis, the sensitivity and PPV were as follows: BEAV, 75.7% and 74.6%, respectively; VRE-BMX, 95.5% and 91.3%, respectively. In this initial evaluation, we found that VRE-BMX provided improved recovery of VRE from stool specimens, with the added advantage of being able to differentiate between vancomycin-resistant E. faecalis and E. faecium. Extending the incubation period beyond 24 h did not significantly improve the recovery of VRE and resulted in decreased specificity.

  19. The Growth of Steroidobacter agariperforans sp. nov., a Novel Agar-Degrading Bacterium Isolated from Soil, is Enhanced by the Diffusible Metabolites Produced by Bacteria Belonging to Rhizobiales

    PubMed Central

    Sakai, Masao; Hosoda, Akifumi; Ogura, Kenjiro; Ikenaga, Makoto

    2014-01-01

    An agar-degrading bacterium was isolated from soil collected in a vegetable cropping field. The growth of this isolate was enhanced by supplying culture supernatants of bacteria belonging to the order Rhizobiales. Phylogenetic analysis based on 16S rRNA gene sequences indicated the novel bacterium, strain KA5–BT, belonged to the genus Steroidobacter in Gammaproteobacteria, but differed from its closest relative, Steroidobacter denitrificans FST, at the species level with 96.5% similarity. Strain KA5–BT was strictly aerobic, Gram-negative, non-motile, non-spore forming, and had a straight to slightly curved rod shape. Cytochrome oxidase and catalase activities were positive. The strain grew on media containing culture supernatants in a temperature range of 15–37°C and between pH 4.5 and 9.0, with optimal growth occurring at 30°C and pH 6.0–8.0. No growth occurred at 10 or 42°C or at NaCl concentrations more than 3% (w/v). The main cellular fatty acids were iso–C15:0, C16:1ω7c, and iso–C17:1ω9c. The main quinone was ubiquinone-8 and DNA G+C content was 62.9 mol%. In contrast, strain FST was motile, did not grow on the agar plate, and its dominant cellular fatty acids were C15:0 and C17:1ω8c. Based on its phylogenetic and phenotypic properties, strain KA5–BT (JCM 18477T = KCTC 32107T) represents a novel species in genus Steroidobacter, for which the name Steroidobacter agariperforans sp. nov. is proposed. PMID:24621511

  20. Contact angle hysteresis explained.

    PubMed

    Gao, Lichao; McCarthy, Thomas J

    2006-07-04

    A view of contact angle hysteresis from the perspectives of the three-phase contact line and of the kinetics of contact line motion is given. Arguments are made that advancing and receding are discrete events that have different activation energies. That hysteresis can be quantified as an activation energy by the changes in interfacial area is argued. That this is an appropriate way of viewing hysteresis is demonstrated with examples.

  1. Soft contact lenses

    PubMed Central

    Sutherland, R. L.; VanLeeuwen, Wm. N.

    1972-01-01

    A series of 55 patients were fitted with a new type of hydrophilic soft contact lens. These were found more comfortable than hard contact lenses and they had a protective and pain-relieving action in cases of chronic corneal disease. Vision was not as good as with hard contact lenses and a greater potential danger of infection was found. They are preferred by many patients despite the noticeable thick edge and the difficulty of obtaining an identical replacement. PMID:5042887

  2. Evaluation of a new agar in Uricult-Trio for rapid detection of Escherichia coli in urine.

    PubMed Central

    Dalet, F; Segovia, T

    1995-01-01

    A new commercial agar (Uricult-Trio) with 8-hydroxyquinoline-beta-glucuronide was used to assess 2,536 uropathogens for beta-glucuronidase activity typical of Escherichia coli. Included in the study were 1,807 strains of the family Enterobacteriaceae, 284 strains of nonfermentative bacilli, 345 strains of gram-positive cocci, and 100 yeast strains. In identifying E. coli, the test agar gave a sensitivity of 95.5% and a specificity of 97.2%. Fifty E. coli isolates gave negative reactions; 31 non-E. coli strains produced black colonies characteristic of E. coli. No growth of gram-positive cocci and no false-positive reactions from yeasts were observed. The recovery rate for E. coli on this agar was at least 10% higher than that on blood agar. PMID:7615766

  3. Comparative avoidance behaviour of the earthworm Eisenia fetida towards chloride, nitrate and sulphate salts of Cd, Cu and Zn using filter paper and extruded water agar gels as exposure media.

    PubMed

    Demuynck, Sylvain; Lebel, Aurélie; Grumiaux, Fabien; Pernin, Céline; Leprêtre, Alain; Lemière, Sébastien

    2016-07-01

    We studied the avoidance behaviour of the earthworm Eisenia fetida towards Cd, Cu, and Zn, trace elements (TEs) tested as chloride, nitrate and sulphate salts. Sub adults were exposed individually using dual-cell chambers at 20+2°C in the dark. Recordings were realised at different dates from 2h to 32h. We used filter paper and extruded water agar gel as exposure media to evaluate the contribution of the dermal and the digestive exposure routes on the avoidance reactions. Exposures to Cu or Cd (10mgmetal ionL(-1)) resulted in highly significant avoidance reactions through the exposure duration. Worms avoided Zn poorly and reactions towards Zn salts varied along the exposure. Worm sensitivity towards TEs differed between salts and this could result from differential toxicity or accessibility of these TE salts to earthworms. The anion in itself was not the determinant of the avoidance reactions since exposures to similar concentrations of these anions using calcium salts did not result in significant avoidance worm behaviour. Avoidance responses towards TEs were higher in the case of water agar exposures than in filter paper exposures. Thus, dermal contacts with TE solutions would elicit worm avoidance but signals from receptors located inside the digestive tract could reinforce this behaviour. The use of extruded water agar gels as the substrate allows checking the real sensitivity of earthworm species towards TEs since the TE concentrations leading to significant avoidance reactions were below those reported in the literature when using TE-spiked soils.

  4. Development of Low Cost Contacts to Silicon Solar Cells

    NASA Technical Reports Server (NTRS)

    Iles, P. A.; Tanner, D. P.

    1979-01-01

    Different electroless plating systems were evaluated in conjunction with copper electroplating. All tests involved simultaneous deposition of front and back contacts using a standard cell materials. Cells with good adhesion and good curve fill factors were obtained using a palladium-chromium-copper metallization system. The final copper contact system was evaluated to determine if the copper would migrate at elevated temperatures. The copper migrated at elevated temperatures causing cell output degradation.

  5. Optical contact micrometer

    DOEpatents

    Jacobson, Steven D.

    2014-08-19

    Certain examples provide optical contact micrometers and methods of use. An example optical contact micrometer includes a pair of opposable lenses to receive an object and immobilize the object in a position. The example optical contact micrometer includes a pair of opposable mirrors positioned with respect to the pair of lenses to facilitate viewing of the object through the lenses. The example optical contact micrometer includes a microscope to facilitate viewing of the object through the lenses via the mirrors; and an interferometer to obtain one or more measurements of the object.

  6. Colors and contact dermatitis.

    PubMed

    Bonamonte, Domenico; Foti, Caterina; Romita, Paolo; Vestita, Michelangelo; Angelini, Gianni

    2014-01-01

    The diagnosis of skin diseases relies on several clinical signs, among which color is of paramount importance. In this review, we consider certain clinical presentations of both eczematous and noneczematous contact dermatitis in which color plays a peculiar role orientating toward the right diagnosis. The conditions that will be discussed include specific clinical-morphologic subtypes of eczematous contact dermatitis, primary melanocytic, and nonmelanocytic contact hyperchromia, black dermographism, contact chemical leukoderma, and others. Based on the physical, chemical, and biologic factors underlying a healthy skin color, the various skin shades drawing a disease picture are thoroughly debated, stressing their etiopathogenic origins and histopathologic aspects.

  7. Performance of the EUCAST disk diffusion method, the CLSI agar screen method, and the Vitek 2 automated antimicrobial susceptibility testing system for detection of clinical isolates of Enterococci with low- and medium-level VanB-type vancomycin resistance: a multicenter study.

    PubMed

    Hegstad, Kristin; Giske, Christian G; Haldorsen, Bjørg; Matuschek, Erika; Schønning, Kristian; Leegaard, Truls M; Kahlmeter, Gunnar; Sundsfjord, Arnfinn

    2014-05-01

    Different antimicrobial susceptibility testing methods to detect low-level vancomycin resistance in enterococci were evaluated in a Scandinavian multicenter study (n=28). A phenotypically and genotypically well-characterized diverse collection of Enterococcus faecalis (n=12) and Enterococcus faecium (n=18) strains with and without nonsusceptibility to vancomycin was examined blindly in Danish (n=5), Norwegian (n=13), and Swedish (n=10) laboratories using the EUCAST disk diffusion method (n=28) and the CLSI agar screen (n=18) or the Vitek 2 system (bioMérieux) (n=5). The EUCAST disk diffusion method (very major error [VME] rate, 7.0%; sensitivity, 0.93; major error [ME] rate, 2.4%; specificity, 0.98) and CLSI agar screen (VME rate, 6.6%; sensitivity, 0.93; ME rate, 5.6%; specificity, 0.94) performed significantly better (P=0.02) than the Vitek 2 system (VME rate, 13%; sensitivity, 0.87; ME rate, 0%; specificity, 1). The performance of the EUCAST disk diffusion method was challenged by differences in vancomycin inhibition zone sizes as well as the experience of the personnel in interpreting fuzzy zone edges as an indication of vancomycin resistance. Laboratories using Oxoid agar (P<0.0001) or Merck Mueller-Hinton (MH) agar (P=0.027) for the disk diffusion assay performed significantly better than did laboratories using BBL MH II medium. Laboratories using Difco brain heart infusion (BHI) agar for the CLSI agar screen performed significantly better (P=0.017) than did those using Oxoid BHI agar. In conclusion, both the EUCAST disk diffusion and CLSI agar screening methods performed acceptably (sensitivity, 0.93; specificity, 0.94 to 0.98) in the detection of VanB-type vancomycin-resistant enterococci with low-level resistance. Importantly, use of the CLSI agar screen requires careful monitoring of the vancomycin concentration in the plates. Moreover, disk diffusion methodology requires that personnel be trained in interpreting zone edges.

  8. Prospective Two-Center Comparison of Three Chromogenic Agars for Methicillin-Resistant Staphylococcus aureus Screening in Hospitalized Patients

    PubMed Central

    Verhulst, Carlo; Nonhoff, Claire; Nagant, Carole; Denis, Olivier; Kluytmans, Jan

    2015-01-01

    Three chromogenic media, chromID MRSA SMART (SMART), chromID MRSA first generation (chromID), and Brilliance MRSA (OX2), were evaluated for methicillin-resistant Staphylococcus aureus (MRSA) screening using 1,220 samples. The sensitivity at 24 h was significantly better with the SMART agar (66.4%) than that with chromID agar (50.5%). Enrichment and incubation until 48 h are still needed for an optimal yield. PMID:26109446

  9. Cavitation-enhanced delivery of insulin in agar and porcine models of human skin

    NASA Astrophysics Data System (ADS)

    Feiszthuber, Helga; Bhatnagar, Sunali; Gyöngy, Miklós; Coussios, Constantin-C.

    2015-03-01

    Ultrasound-assisted transdermal insulin delivery offers a less painful and less invasive alternative to subcutaneous insulin injections. However, ultrasound-based drug delivery, otherwise known as sonophoresis, is a highly variable phenomenon, in part dependent on cavitation. The aim of the current work is to investigate the role of cavitation in transdermal insulin delivery. Fluorescently stained, soluble Actrapid insulin was placed on the surface of human skin-mimicking materials subjected to 265 kHz, 10% duty cycle focused ultrasound. A confocally and coaxially aligned 5 MHz broadband ultrasound transducer was used to detect cavitation. Two different skin models were used. The first model, 3% agar hydrogel, was insonated with a range of pressures (0.25-1.40 MPa peak rarefactional focal pressure—PRFP), with and without cavitation nuclei embedded within the agar at a concentration of 0.05% w/v. The second, porcine skin was insonated at 1.00 and 1.40 MPa PRFP. In both models, fluorescence measurements were used to determine penetration depth and concentration of delivered insulin. Results show that in agar gel, both insulin penetration depth and concentration only increased significantly in the presence of inertial cavitation, with up to a 40% enhancement. In porcine skin the amount of fluorescent insulin was higher in the epidermis of those samples that were exposed to ultrasound compared to the control samples, but there was no significant increase in penetration distance. The results underline the importance of instigating and monitoring inertial cavitation during transdermal insulin delivery.

  10. Cavitation-enhanced delivery of insulin in agar and porcine models of human skin.

    PubMed

    Feiszthuber, Helga; Bhatnagar, Sunali; Gyöngy, Miklós; Coussios, Constantin-C

    2015-03-21

    Ultrasound-assisted transdermal insulin delivery offers a less painful and less invasive alternative to subcutaneous insulin injections. However, ultrasound-based drug delivery, otherwise known as sonophoresis, is a highly variable phenomenon, in part dependent on cavitation. The aim of the current work is to investigate the role of cavitation in transdermal insulin delivery. Fluorescently stained, soluble Actrapid insulin was placed on the surface of human skin-mimicking materials subjected to 265 kHz, 10% duty cycle focused ultrasound. A confocally and coaxially aligned 5 MHz broadband ultrasound transducer was used to detect cavitation. Two different skin models were used. The first model, 3% agar hydrogel, was insonated with a range of pressures (0.25-1.40 MPa peak rarefactional focal pressure-PRFP), with and without cavitation nuclei embedded within the agar at a concentration of 0.05% w/v. The second, porcine skin was insonated at 1.00 and 1.40 MPa PRFP. In both models, fluorescence measurements were used to determine penetration depth and concentration of delivered insulin. Results show that in agar gel, both insulin penetration depth and concentration only increased significantly in the presence of inertial cavitation, with up to a 40% enhancement. In porcine skin the amount of fluorescent insulin was higher in the epidermis of those samples that were exposed to ultrasound compared to the control samples, but there was no significant increase in penetration distance. The results underline the importance of instigating and monitoring inertial cavitation during transdermal insulin delivery.

  11. Methicillin-Resistant Staphylococcus aureus Grown on Vancomycin-Supplemented Screening Agar Displays Enhanced Biofilm Formation

    PubMed Central

    Chang, Wenjiao; Ding, Ding; Zhang, Shanshan; Dai, Yuanyuan; Pan, Qing; Lu, Huaiwei; Luo, Qingli; Shen, Jilong

    2015-01-01

    Brain heart infusion agar containing 3 mg/liter vancomycin (BHI-V3) was used to screen for heterogeneous vancomycin-intermediate Staphylococcus aureus (hVISA). There was markedly greater biofilm formation by isolates that grew on BHI-V3 than by strains that did not grow on BHI-V3. Increased biofilm formation by hVISA may be mediated by FnbA- and polysaccharide intercellular adhesin-dependent pathways, and upregulation of atlA and sarA may also contribute to enhanced biofilm formation by hVISA upon prolonged exposure to vancomycin. PMID:26459889

  12. Coma in the course of severe poisoning after consumption of red fly agaric (Amanita muscaria).

    PubMed

    Mikaszewska-Sokolewicz, Małgorzata A; Pankowska, Sylwestra; Janiak, Marek; Pruszczyk, Piotr; Łazowski, Tomasz; Jankowski, Krzysztof

    2016-01-01

    Red fly agaric poisoning is rare. It can be consumed for suicidal purposes or its psychedelic effect. The paper describes the case of a young men, who fell into a coma after ingestion of the red toadstools. Quick identification of the poison, early use of gastric lavage and symptomatic treatment resulted in regression of symptoms and lead to the patient's discharge from the hospital on the third day after intoxication. Authors discussing the poisonous alkaloids contained in the red toadtools: ibotenic acid, muscimol, muscasone and muscarine and theirs properties, responsible for the symptoms of intoxication.

  13. CHROMagar Yersinia, a New Chromogenic Agar for Screening of Potentially Pathogenic Yersinia enterocolitica Isolates in Stools

    PubMed Central

    Renaud, Nicolas; Lecci, Laetitia; Courcol, René J.; Simonet, Michel

    2013-01-01

    CHROMagar Yersinia (CAY) is a new chromogenic medium for the presumptive detection of virulent Yersinia enterocolitica in stools. Based on a comparative analysis of 1,494 consecutive stools from hospitalized patients, CAY was found to be just as sensitive as the reference medium (cefsulodin-irgasan-novobiocin agar) but was significantly more specific and had a very low false-positive rate. CAY reduces the workload (and thus costs) for stool analysis and can therefore be recommended for routine laboratory use. PMID:23363840

  14. Comparative study of 6-APA production by free and agar immobilized bacteria in nutrient broth culture.

    PubMed

    Dolui, A K; Das, S

    2011-04-01

    In the present study different bacterial samples were isolated from soil of different places of Dibrugarh and screened for biotransformation ability to produce 6-Aminopenicillanic acid. Among ten isolated bacterial samples, three gram positive bacterial samples designated as AKDD-2, AKDD-4 and AKDD-6 showed the production of 6-APA from penicillin G. Assessment of production of 6-APA after incubation in penicillin G (2 mg/ml) by three different samples separately in free and agar immobilization state was done by HPLC analysis. Reusability of immobilized cells was found successful up to 14 days.

  15. Caribbean plate interactions

    SciTech Connect

    Ball, M. )

    1993-02-01

    Vector analysis of plate motions, derived from studies of Atlantic magnetic lineations and fracture zone trends, indicates the following relative movements between the Caribbean, North American, and South American Plates. (1) During Early Jurassic to Early Cretaceous, the North American Plate moved 1900 km westward and 900 km northward relative to the South American Plate. A broad zone including the Caribbean region, i.e., the zone between the North and South America Plates, was a site of left-lateral shear and north-south extension. (2) During Early Cretaceous to Late Cretaceous, the North American Mate moved an additional 1200 km westward relative to South America across this zone. (3) During Late Cretaceous to the end of the Eocene, the North American Plate moved 200 km westward and 400 km northward relative to the South American Plate. (4) From the end of the Eocene to near the end of the Miocene, North America converged on South America some 200 km and moved 100 km eastward relative to it. Through the Mesozoic and earliest Tertiary history of the Caribbean, the region was a shear zone within which left-lateral displacement exceeded 3000 km and north-south extension exceeded 1300 km. In regard to time, 80% of the history of the Caribbean region is one of north-south extension and left-lateral shear. In terms of space, 97% of the shear is left-lateral and the ratio of divergence versus convergence is 7 to 1. Thus, characterizing the Caribbean region, and the Atlantic to its east, as a zone of north-south extension and left-lateral shear, is a fair generalization.

  16. Laser microwelding of small diameter wire to a contact

    SciTech Connect

    Wojcicki, M.A.; Pryputniewicz, R.J.

    1996-12-31

    This work is an attempt to evaluate feasibility of the laser welding process of small diameter wire to a contact. In particular, the paper addresses characterization of laser spot welded 32 AWG solid copper/silver plated wires to contacts on 0.050 in. centers. The copper alloy contacts were provided on strips in two lots, one unplated, and the other with 75 {mu}in. of plated Nickel. An industrial type IR, Nd:YAG, pulsed laser was used to produce welds, in order to simulate manufacturing environment. Metallurgical analysis, SEM, and nanoindentation characterization have been used in setting up the welding process and in final evaluation. Quality of welds was also evaluated by a tensile test and the results are presented in a statistical format. The test results indicate that the tensile strength of the laser welded wire, relative to the bare (unwelded) wire, yielded 95.47% for joints on unplated contacts, and 98.25% for Nickel plated contacts. Microscope examination of samples, after pull test, shows that all wires broke behind the weld area. These results significantly exceed the required minimum tensile of a welded joint, which is 60% of the tensile strength of a bare wire. They also indicate that laser welding of small diameter wires to high density contacts can be considered as a valuable process alternative.

  17. Antibiotic susceptibility of Stenotrophomonas (Xanthomonas) maltophilia: comparative (NCCLS criteria) evaluation of antimicrobial drugs with the agar dilution and the agar disk diffusion (Bauer-Kirby) tests.

    PubMed

    Traub, W H; Leonhard, B; Bauer, D

    1998-01-01

    Ninety-six clinical isolates of Stenotrophomonas maltophilia were examined with the agar dilution method for susceptibility to 19 antimicrobial drugs. Doxycycline, cotrimoxazole, timentin, ofloxacin, fosfomycin, and piperacillin + tazobactam, in that order, inhibited the majority of strains. All isolates were resistant to nitrofurantoin. Concurrent disk susceptibility (Bauer-Kirby method) testing, using currently valid NCCLS interpretative criteria for Pseudomonas aeruginosa, uncovered a significant incidence of very major (category I), major (category II), and minor (categories III and IV) discrepancies for aminoglycosides, cephalosporins, chloramphenicol, and piperacillin + tazobactam and ticarcillin + clavulanic acid. Therefore, new interpretative criteria indicative of intermediate (I) susceptibility of S. maltophilia to these various antibiotics were proposed. In addition, new intermediate susceptibility criteria were proposed for the two beta-lactam-beta-lactamase inhibitor combinations. It was recommended to exclude ciprofloxacin from test batteries against this microorganism due to the wide scatter of minimal inhibitory concentration values and diameters of inhibition zones; the same was true for polymyxin B. It is hoped that the proposed modified, species-specific criteria will improve the clinical utility of laboratory-generated disk antibiograms with respect to the inherently multiple antibiotic-resistant, opportunistic pathogen S. maltophilia.

  18. Cadmium plating replacements

    SciTech Connect

    Nelson, M.J.; Groshart, E.C.

    1995-03-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  19. Cadmium plating replacements

    NASA Technical Reports Server (NTRS)

    Nelson, Mary J.; Groshart, Earl C.

    1995-01-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  20. Factor XII Contact Activation.

    PubMed

    Naudin, Clément; Burillo, Elena; Blankenberg, Stefan; Butler, Lynn; Renné, Thomas

    2017-03-27

    Contact activation is the surface-induced conversion of factor XII (FXII) zymogen to the serine protease FXIIa. Blood-circulating FXII binds to negatively charged surfaces and this contact to surfaces triggers a conformational change in the zymogen inducing autoactivation. Several surfaces that have the capacity for initiating FXII contact activation have been identified, including misfolded protein aggregates, collagen, nucleic acids, and platelet and microbial polyphosphate. Activated FXII initiates the proinflammatory kallikrein-kinin system and the intrinsic coagulation pathway, leading to formation of bradykinin and thrombin, respectively. FXII contact activation is well characterized in vitro and provides the mechanistic basis for the diagnostic clotting assay, activated partial thromboplastin time. However, only in the past decade has the critical role of FXII contact activation in pathological thrombosis been appreciated. While defective FXII contact activation provides thromboprotection, excess activation underlies the swelling disorder hereditary angioedema type III. This review provides an overview of the molecular basis of FXII contact activation and FXII contact activation-associated disease states.

  1. Elastocapillary coalescence of plates and pillars

    PubMed Central

    Wei, Z.; Schneider, T. M.; Kim, J.; Kim, H.-Y.; Aizenberg, J.; Mahadevan, L.

    2015-01-01

    When a fluid-immersed array of supported plates or pillars is dried, evaporation leads to the formation of menisci on the tips of the plates or pillars that bring them together to form complex patterns. Building on prior experimental observations, we use a combination of theory and computation to understand the nature of this instability and its evolution in both the two- and three-dimensional setting of the problem. For the case of plates, we explicitly derive the interaction torques based on the relevant physical parameters associated with pillar deformation, contact-line pinning/depinning and fluid volume changes. A Bloch-wave analysis for our periodic mechanical system captures the window of volumes where the two-plate eigenvalue characterizes the onset of the coalescence instability. We then study the evolution of these binary clusters and their eventual elastic arrest using numerical simulations that account for evaporative dynamics coupled to capillary coalescence. This explains both the formation of hierarchical clusters and the sensitive dependence of the final structures on initial perturbations, as seen in our experiments. We then generalize our analysis to treat the problem of pillar collapse in three dimensions, where the fluid domain is completely connected and the interface is a minimal surface with the uniform mean curvature. Our theory and simulations capture the salient features of experimental observations in a range of different situations and may thus be useful in controlling the ensuing patterns. PMID:25792949

  2. Noneczematous Contact Dermatitis

    PubMed Central

    Foti, Caterina; Vestita, Michelangelo; Angelini, Gianni

    2013-01-01

    Irritant or allergic contact dermatitis usually presents as an eczematous process, clinically characterized by erythematoedematovesicous lesions with intense itching in the acute phase. Such manifestations become erythematous-scaly as the condition progresses to the subacute phase and papular-hyperkeratotic in the chronic phase. Not infrequently, however, contact dermatitis presents with noneczematous features. The reasons underlying this clinical polymorphism lie in the different noxae and contact modalities, as well as in the individual susceptibility and the various targeted cutaneous structures. The most represented forms of non-eczematous contact dermatitis include the erythema multiforme-like, the purpuric, the lichenoid, and the pigmented kinds. These clinical entities must obviously be discerned from the corresponding “pure” dermatitis, which are not associated with contact with exogenous agents. PMID:24109520

  3. Quantification of a contact stimulus by diapers

    NASA Astrophysics Data System (ADS)

    Nomata, Takuya; Okuyama, Takeshi; Teraoka, Hiromi; Murakami, Yasuo; Miyazawa, Kiyoshi; Tanaka, Mami

    2010-01-01

    This paper describes a development of a sensor system for measurement of a contact stimulus which diapers give to infants. A polyvinyliden fluoride (PVDF) film and a strain gauge are used as the sensor receptors. The PVDF is a kind of piezoelectric material. The sensor consists of a surface contact layer, a PVDF film, a strain gauge and an aluminum plate. First, in order to investigate the sensor performance, the sensor was located on a silicone plate and the upper part of the sensor was rubbed with an acrylic artificial finger. The finger enabled the measurement to carry out at a constant speed and force. Next, the sensor was attached on an infant dummy and the sensor outputs were measured under conditions with and without diapers. By comparison of the output under two different conditions, it was confirmed that there is a clearly difference between the two conditions. It was found that the developed sensor system has the possibility to quantify a contact stimulus which diapers give infants.

  4. Quantification of a contact stimulus by diapers

    NASA Astrophysics Data System (ADS)

    Nomata, Takuya; Okuyama, Takeshi; Teraoka, Hiromi; Murakami, Yasuo; Miyazawa, Kiyoshi; Tanaka, Mami

    2009-12-01

    This paper describes a development of a sensor system for measurement of a contact stimulus which diapers give to infants. A polyvinyliden fluoride (PVDF) film and a strain gauge are used as the sensor receptors. The PVDF is a kind of piezoelectric material. The sensor consists of a surface contact layer, a PVDF film, a strain gauge and an aluminum plate. First, in order to investigate the sensor performance, the sensor was located on a silicone plate and the upper part of the sensor was rubbed with an acrylic artificial finger. The finger enabled the measurement to carry out at a constant speed and force. Next, the sensor was attached on an infant dummy and the sensor outputs were measured under conditions with and without diapers. By comparison of the output under two different conditions, it was confirmed that there is a clearly difference between the two conditions. It was found that the developed sensor system has the possibility to quantify a contact stimulus which diapers give infants.

  5. Thin plastic sheet eliminates need for expensive plating

    NASA Technical Reports Server (NTRS)

    Stremel, R. L.

    1967-01-01

    Gasket of a commercially available plastic material is interposed between the mating surfaces in axial joints where a hard and a soft metal are in intimate contact under stress conditions. This eliminates the fretting problem and is quicker and less expensive than the plating process.

  6. Evaluation of commercial selective agars in screening for methicillin-resistant Staphylococcus aureus.

    PubMed

    Yang, Hee-Young; Suh, Jin-Tae; Lee, Hee-Joo

    2010-01-01

    To evaluate methicillin-resistant S. aureus (MRSA) detection methods, we compared (a) mannitol salt agar with cefoxitin (MSA-FX), (b) MRSASelect agar (Bio-Rad), (c) MRSA ID (bioMerieuex), and (d) CHROMagar MRSA (BD Diagnostics) as selective media for culturing nasal swab specimens collected from intensive care unit (ICU) patients and healthcare personnel. A total of 99 (17.1%) cases of MRSA were recovered from 578 specimens. Four (5.5%) cases were identified from healthcare personnel and 95 (18.8%) were from ICU patients. The sensitivity of MSA-FX, MRSASelect, MRSA ID, and CHROMagar MRSA was 83.8, 87.9, 80.8, and 84.8% after 18 hr; 92.9, 94.9, 90.9, and 91.9% after 24 hr; and 96.0, 100, 99.0, and 99.0% after 48 hr, respectively. The specificity of MSA-FX, MRSASelect, MRSA ID, and CHROMagar MRSA was 97.7, 99.0, 98.7. and 99.8% after 18 hr; 97.1, 98.5, 98.1, and 99.5% after 24 hr; and 95.2, 97.7, 97.9, and 99.0% after 48 hr, respectively. In conclusion, all four media showed good results after the 24 hr readings, but MRSA ID and CHROMagar MRSA media required readings at 48 hr due to increased sensitivity at this time point.

  7. Measuring Survival of Hematopoietic Cancer Cells with the Colony-Forming Assay in Soft Agar.

    PubMed

    Crowley, Lisa C; Waterhouse, Nigel J

    2016-08-01

    Colony-forming assays measure the ability of cells in culture to grow and divide into groups. Any cell that has the potential to form a colony may also have the potential to cause cancer or relapse in vivo. Colony-forming assays also provide an indirect measurement of cell death because any cell that is dead or dying will not continue to proliferate. The proliferative capacity of adherent cells such as fibroblasts can be determined by growing cells at low density on culture dishes and counting the number of distinct groups that form over time. Cells that grow in suspension, such as hematopoietic cells, cannot be assayed this way because the cells move freely in the media. Assays to determine the colony-forming ability of hematopoietic cells must therefore be performed in solid matrices that restrict large-scale movement of the cells. One such matrix is soft agar. This protocol describes the use of soft agar to compare the colony-forming ability of untreated hematopoietic cells to the colony-forming ability of hematopoietic cells that have been treated with a cytotoxic agent.

  8. [Development of chromogenic agar medium for isolation of enterohaemorrhagic Escherichia coli O26].

    PubMed

    Ikedo, M; Komatsu, O; Hara-Kudo, Y; Yamamoto, S; Kumagai, S

    2001-04-01

    Agar media for isolation of enterohaemorrhagic Escherichia coli (EHEC) have been developed primarily for E. coli O157, because this bacterium has most frequently caused EHEC infection. However, there have been few studies for isolation of other serotypes of EHEC, and media appropriate for isolation of such organisms, especially from food samples, are not yet available. Among such serotypes, E. coli O26 has often been isolated from clinical specimens from patients and animals, but not from food samples in outbreaks, because of lack of an appropriate method for isolation. In this study, we tried to develop a new chromogenic agar medium for selective isolation of E. coli O26 using the characteristics of E. coli O26. Fifteen strains of E. coli O26, 11 strains of E. coli O157 and 36 strains of other sero-types E. coli were tested for fermentation of rhamnose, cellobiose, dulcitol, salicin, raffinose, sorbitol, sucrose, lactose, mannitol, arabinose, maltose, xylose and glucose. Rhamnose was fermented by all E. coli strains except for E. coli O26. The other substrates were not effective for differentiating E. coli O26 from the other strains of E. coli. Thus the medium containing rhamnose and 5-bromo-4-chloro-3-indolyl-beta-D-galactopyranoside, which is a substrate of beta-galactosidase specific to coliforms, produced a color of E. coli O26 colonies different from colors of the other bacteria. Furthermore, cefixime and sodium tellulite were added to the composition of the medium for gaining higher selectivity.

  9. An electrochemical approach to monitor pH change in agar media during plant tissue culture.

    PubMed

    Wang, Min; Ha, Yang

    2007-05-15

    In this work, metal oxide microelectrodes were developed to monitor pH change in agar media during plant tissue culture. An antimony wire was produced by a new approach "capillary melt method". The surface of the obtained antimony wire was oxidized in a potassium nitrate melt to fabricate an antimony oxide film for pH sensing. Characterization results show that the oxide layer grown on the wire surface consists of Sb(2)O(3) crystal phase. The sensing response, open-circuit potential, of the electrode has a good linear relationship (R(2)=1.00) with pH value of the test solution. Adding organic compounds into the test media would not affect the linear relationship, although the slope of the lines varied with different ingredients added. The antimony oxide electrodes were employed to continuously monitor pH change of agar culture media during a 2-week plant tissue culture of Dendrobium candidum. The antimony oxide electrode fabricated this way has the advantages of low cost, easy fabrication, fast response, and almost no contamination introduced into the system. It would be suitable for in situ and continuous pH measurement in many bio applications.

  10. Mechanical response of agar gel irradiated with Nd:YAG nanosecond laser pulses

    NASA Astrophysics Data System (ADS)

    Pérez-Gutiérrez, Francisco G.; Evans, Rodger; Camacho-López, Santiago; Aguilar, Guillermo

    2010-02-01

    Nanosecond long laser pulses are used in medical applications where precise tissue ablation with minimal thermal and mechanical collateral damage is required. When a laser pulse is incident on a material, optical energy will be absorbed by a combination of linear and nonlinear absorption according to both: laser light intensity and material properties. In the case of water or gels, the first results in heat generation and thermoelastic expansion; while the second results in an expanding plasma formation that launches a shock wave and a cavitation/boiling bubble. Plasma formation due to nonlinear absorption of nanosecond laser pulses is originated by a combination of multiphoton ionization and thermionic emission of free electrons, which is enhanced when the material has high linear absorption coefficient. In this work, we present measurements of pressure transients originated when 6 ns laser pulses are incident on agar gels with varying linear absorption coefficient, mechanical properties and irradiation geometry using laser radiant exposures above threshold for bubble formation. The underlying hypothesis is that pressure transients are composed of the superposition of both: shock wave originated by hot expanding plasma resulting from nonlinear absorption of optical energy and, thermoelastic expansion originated by heat generation due to linear absorption of optical energy. The objective of this work is to evaluate the relative contribution of each absorption mechanism to mechanical effects in agar gel. Real time pressure transients are recorded with PVDF piezoelectric sensors and time-resilved imaging from 50 μm to 10 mm away from focal point.

  11. Evaluation of brilliance CRE agar for the detection of carbapenem-resistant gram-negative bacteria.

    PubMed

    Bracco, Silvia; Migliavacca, Roberta; Pini, Beatrice; Corbo, Nicoletta; Nucleo, Elisabetta; Brigante, Gioconda; Piazza, Aurora; Micheletti, Piero; Luzzaro, Francesco

    2013-04-01

    The aim of this work was to evaluate the performance of the new chromogenic medium BrillianceTM CREAgar (Thermo Fisher Scientific) for determining the limit of detection of carbapenem-resistant enterobacteria (CRE). A total of 70 clinical isolates were studied. Of these, 30 were well-characterized CRE, including Klebsiella pneumoniae strains producing KPC-, VIM-, and OXA-type enzymes, VIM-positive Enterobacter cloacae and Escherichia coli, NDM-positive E. coli, and enterobacterial isolates characterized by porin loss associated with ESBL production or AmpC hyperproduction. Ten carbapenem-resistant non-fermentative isolates were also included as well as 30 carbapenem-susceptible isolates. Carbapenem-resistant strains were inoculated at three different concentrations onto Brilliance CRE Agar (from 1.5x101 CFU/ml up to 1.5x104 CFU/ml) whereas carbapenem-susceptible isolates were inoculated at a concentration of 1.5x102 CFU/ml. The medium sustained the growth of carbapenem-resistant isolates, showing detection limits from 1.5x101 CFU/ml (in 31/40 cases) to 1.5x104 CFU/ml. No growth was observed with carbapenem-sensitive control strains. Our results indicate that the Brilliance CRE Agar allows the growth of carbapenem-resistant isolates with low detection limits and could represent a useful screening medium for both enterobacteria and non-fermentative Gram-negative strains resistant to carbapenems.

  12. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1987-01-01

    A liquid-impermeable plate (10) having through-plate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with led spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  13. Plate-mantle coupling from post-Pangea plate kinematics

    NASA Astrophysics Data System (ADS)

    Zahirovic, Sabin; Dietmar Müller, R.; Seton, Maria; Flament, Nicolas

    2015-04-01

    Convection in the Earth's mantle that involves plates at the surfaces gives rise to plate velocities that vary through time and depend on the balance of plate boundary forces, with the present-day providing a snapshot of this ongoing process. However, present-day plate velocities do not capture plate behaviour over geologically representative timeframes and thus cannot be used to evaluate factors limiting plate velocities. Previous studies investigated the effects of continental keels on plate speeds by either using the present-day snapshot or a limited number of reconstructed plate configurations, often leading to conflicting results. For example, an early assumption was that continental keels (especially cratons) were unlikely to impede fast plate motions because India's velocity approached ~20 cm/yr in the Eocene prior to the collision with Eurasia. We employ a modern plate reconstruction approach with evolving global topological plate boundaries for the post-Pangea timeframe (since 200 Ma) to evaluate factors controlling plate velocities. Plate boundary configurations and plate velocities are extracted from the open-source and cross-platform plate reconstruction package GPlates (www.gplates.org) at 1 Myr intervals. For each plate, at each timestep, the area of continental and cratonic lithosphere is calculated to evaluate the effect on plate velocities. Our results support that oceanic plates tend to be 2-3 times faster than plates with large portion of continental plate area, consistent with predictions of numerical models of mantle convection. The fastest plates (~8.5 cm/yr RMS) are dominated by oceanic plate area and high subducting portion of plate perimeter, while the slowest plates (~2.6-2.8 cm/yr RMS) are dominated by continental plate area and bounded by transforms and mid-oceanic ridge segments. Importantly, increasing cratonic fractions (both Proterozoic and Archean lithosphere) significantly impede plate velocities, suggesting that deep continental

  14. Stable isotope ratios as a tool in microbial forensics--part 3. Effect of culturing on agar-containing growth media.

    PubMed

    Kreuzer-Martin, Helen W; Chesson, Lesley A; Lott, Michael J; Ehleringer, James R

    2005-11-01

    Stable isotope ratios of hydrogen and oxygen in microbes have been shown to be functions of the corresponding isotope ratios of the water with which the culture medium was prepared, and thus to contain a potential geographic signal. Water can evaporate from agar (solid) media during culturing, changing its isotope ratios. Here we describe the effect of drying on the isotope ratios of water extracted from agar media and the H and O stable isotope ratios ratios of Bacillus subtilis spores cultured on agar. The delta2H vs delta18O relationship of water in Petri dish agar was surprisingly constant during evaporation regardless of the ambient relative humidity, making it possible to calculate the approximate isotope ratios of the original water, even in significantly evaporated agar. The H stable isotope ratios of spores cultured on agar remained relatively unchanged as the agar dried, but the O ratio became significantly enriched.

  15. Comparison of plate counts, Petrifilm, dipslides, and adenosine triphosphate bioluminescence for monitoring bacteria in cooling-tower waters.

    PubMed

    Mueller, Sherry A; Anderson, James E; Kim, Byung R; Ball, James C

    2009-04-01

    Effective bacterial control in cooling-tower systems requires accurate and timely methods to count bacteria. Plate-count methods are difficult to implement on-site, because they are time- and labor-intensive and require sterile techniques. Several field-applicable methods (dipslides, Petrifilm, and adenosine triphosphate [ATP] bioluminescence) were compared with the plate count for two sample matrices--phosphate-buffered saline solution containing a pure culture of Pseudomonas fluorescens and cooling-tower water containing an undefined mixed bacterial culture. For the pure culture, (1) counts determined on nutrient agar and plate-count agar (PCA) media and expressed as colony-forming units (CFU) per milliliter were equivalent to those on R2A medium (p = 1.0 and p = 1.0, respectively); (2) Petrifilm counts were not significantly different from R2A plate counts (p = 0.99); (3) the dipslide counts were up to 2 log units higher than R2A plate counts, but this discrepancy was not statistically significant (p = 0.06); and (4) a discernable correlation (r2 = 0.67) existed between ATP readings and plate counts. For cooling-tower water samples (n = 62), (1) bacterial counts using R2A medium were higher (but not significant; p = 0.63) than nutrient agar and significantly higher than tryptone-glucose yeast extract (TGE; p = 0.03) and PCA (p < 0.001); (2) Petrifilm counts were significantly lower than nutrient agar or R2A (p = 0.02 and p < 0.001, respectively), but not statistically different from TGE, PCA, and dipslides (p = 0.55, p = 0.69, and p = 0.91, respectively); (3) the dipslide method yielded bacteria counts 1 to 3 log units lower than nutrient agar and R2A (p < 0.001), but was not significantly different from Petrifilm (p = 0.91), PCA (p = 1.00) or TGE (p = 0.07); (4) the differences between dipslides and the other methods became greater with a 6-day incubation time; and (5) the correlation between ATP readings and plate counts varied from system to system, was poor

  16. Reduced Plating Ignitron

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A (Inventor); Pearson, J Boise (Inventor)

    2014-01-01

    An ignitron apparatus has an airtight tubular housing having a first sealed end and a second sealed end. An anode is connected at the first sealed end, projecting into the housing, and a recess at the second sealed and forms a well which contains a quantity of liquid gallium or gallium alloy making up the cathode. An ignitor projects through the liquid metal and into the housing. The inner surface of the housing includes at least one plating-reduction structure to prevent electrical shorting of the apparatus caused by plating of the liquid metal.

  17. License plate detection algorithm

    NASA Astrophysics Data System (ADS)

    Broitman, Michael; Klopovsky, Yuri; Silinskis, Normunds

    2013-12-01

    A novel algorithm for vehicle license plates localization is proposed. The algorithm is based on pixel intensity transition gradient analysis. Near to 2500 natural-scene gray-level vehicle images of different backgrounds and ambient illumination was tested. The best set of algorithm's parameters produces detection rate up to 0.94. Taking into account abnormal camera location during our tests and therefore geometrical distortion and troubles from trees this result could be considered as passable. Correlation between source data, such as license Plate dimensions and texture, cameras location and others, and parameters of algorithm were also defined.

  18. Antimicrobial activity of ProRoot MTA in contact with blood

    PubMed Central

    Farrugia, C.; Baca, P.; Camilleri, J.; Arias Moliz, M. T.

    2017-01-01

    Dental materials based on Portland cement, which is used in the construction industry have gained popularity for clinical use due to their hydraulic properties, the interaction with tooth tissue and their antimicrobial properties. The antimicrobial properties are optimal in vitro. However in clinical use contact with blood may affect the antimicrobial properties. This study aims to assess whether antimicrobial properties of the Portland cement-based dental cements such as mineral trioxide aggregate (MTA) are also affected by contact with blood present in clinical situations. ProRoot MTA, a Portland cement-based dental cement was characterized following contact with water, or heparinized blood after 1 day and 7 days aging. The antimicrobial activity under the mentioned conditions was assessed using 3 antimicrobial tests: agar diffusion test, direct contact test and intratubular infection test. MTA in contact with blood was severely discoloured, exhibited an additional phosphorus peak in elemental analysis, no calcium hydroxide peaks and no areas of bacterial inhibition growth in the agar diffusion test were demonstrated. ProRoot MTA showed limited antimicrobial activity, in both the direct contact test and intratubular infection test. When aged in water ProRoot MTA showed higher antimicrobial activity than when aged in blood. Antimicrobial activity reduced significantly after 7 days. Further assessment is required to investigate behaviour in clinical situations. PMID:28128328

  19. Antimicrobial activity of ProRoot MTA in contact with blood.

    PubMed

    Farrugia, C; Baca, P; Camilleri, J; Arias Moliz, M T

    2017-01-27

    Dental materials based on Portland cement, which is used in the construction industry have gained popularity for clinical use due to their hydraulic properties, the interaction with tooth tissue and their antimicrobial properties. The antimicrobial properties are optimal in vitro. However in clinical use contact with blood may affect the antimicrobial properties. This study aims to assess whether antimicrobial properties of the Portland cement-based dental cements such as mineral trioxide aggregate (MTA) are also affected by contact with blood present in clinical situations. ProRoot MTA, a Portland cement-based dental cement was characterized following contact with water, or heparinized blood after 1 day and 7 days aging. The antimicrobial activity under the mentioned conditions was assessed using 3 antimicrobial tests: agar diffusion test, direct contact test and intratubular infection test. MTA in contact with blood was severely discoloured, exhibited an additional phosphorus peak in elemental analysis, no calcium hydroxide peaks and no areas of bacterial inhibition growth in the agar diffusion test were demonstrated. ProRoot MTA showed limited antimicrobial activity, in both the direct contact test and intratubular infection test. When aged in water ProRoot MTA showed higher antimicrobial activity than when aged in blood. Antimicrobial activity reduced significantly after 7 days. Further assessment is required to investigate behaviour in clinical situations.

  20. Method of obtaining intensified image from developed photographic films and plates

    NASA Technical Reports Server (NTRS)

    Askins, B. S. (Inventor)

    1978-01-01

    A method is explained of obtaining intensified images from silver images on developed photographic films and plates. The steps involve converting silver of the developed film or plate to a radioactive compound by treatment with an aqueous alkaline solution of an organo-S35 compound; placing the treated film or plate in direct contact with a receiver film which is then exposed by radiation from the activated film; and developing and fixing the resulting intensified image on the receiver film.

  1. A combined lift and propulsion system of a steel plate by transverse flux linear induction motors

    SciTech Connect

    Hayashiya, H.; Ohsaki, H.; Masada, E.

    1999-09-01

    To realize a non-contacting conveyance of a steel plate, a combined lift and propulsion system of a steel plate by transverse flux linear induction motors (LIMs) is proposed. By introducing the DC biased AC feeding to the LIM< a steel plate is supported stably and efficiently. In this paper, after showing the advantages of the system, the magnetic levitation experiments are carried out to investigate the feasibility of the system.

  2. Point and transfer mobility of point-connected ribbed plates

    NASA Astrophysics Data System (ADS)

    Mayr, A. R.; Gibbs, B. M.

    2011-09-01

    The work reported in this paper addresses the problem of structure-borne sound transmission between vibrating sources and ribbed-plate receiver structures. Vibrating sources, such as pumps, motors, fans, etc., transmit vibro-acoustic power, causing noise complaints by occupants in cars, trains, aircraft, buildings and/or material fatigue and damage. The transmission process is complicated in that sources transmit power through several contacts and by up to six components of excitation at each contact. The structure-borne sound power is a function of source activity, source mobility and receiver mobility, and all three quantities must be known to some degree. For non-homogeneous receiver structures, such as thin-plate cavity constructions or lightweight framed constructions, the sheathing plates are typically fastened to the framing members using bolts, screws or spot-welded joints. Hence the resulting system is a point-connected ribbed plate structure and the receiver mobility is expected to vary significantly with position. Since measured receiver data seldom is available for prediction purposes, a method of estimating the point and transfer mobility of point connected ribbed plates is required. In this paper, an approximate approach, based on substitution forces, is described. The model uses infinite beam and infinite plate behaviour as input quantities. Estimates of point and transfer mobility are compared with measured results using a timber joist floor construction as an example.

  3. The stress distribution in pin-loaded orthotropic plates

    NASA Technical Reports Server (NTRS)

    Klang, E. C.; Hyer, M. W.

    1985-01-01

    The performance of mechanically fastened composite joints was studied. Specially, a single-bolt connector was modeled as a pin-loaded, infinite plate. The model that was developed used two dimensional, complex variable, elasticity techniques combined with a boundary collocation procedure to produce solutions for the problem. Through iteration, the boundary conditions were satisfied and the stresses in the plate were calculated. Several graphite epoxy laminates were studied. In addition, parameters such as the pin modulus, coefficient of friction, and pin-plate clearance were varied. Conclusions drawn from this study indicate: (1) the material properties (i.e., laminate configuration) of the plate alter the stress state and, for highly orthotropic materials, the contact stress deviates greatly from the cosinusoidal distribution often assumed; (2) friction plays a major role in the distribution of stresses in the plate; (3) reversing the load direction also greatly effects the stress distribution in the plate; (4) clearance (or interference) fits change the contact angle and thus the location of the peak hoop stress; and (5) a rigid pin appears to be a good assumption for typical material systems.

  4. Development of low cost contacts to silicon solar cells

    NASA Technical Reports Server (NTRS)

    Tanner, D. P.

    1980-01-01

    The results of the second phase of the program of developing low cost contacts to silicon solar cells using copper are presented. Phase 1 yielded the development of a plated Pd-Cr-Cu contact system. This process produced cells with shunting problems when they were heated to 400 C for 5 minutes. Means of stopping the identified copper diffusion which caused the shunting were investigated. A contact heat treatment study was conducted with Pd-Ag, Ci-Ag, Pd-Cu, Cu-Cr, and Ci-Ni-Cu. Nickel is shown to be an effective diffusion barrier to copper.

  5. Allergic contact dermatitis.

    PubMed

    Becker, Detlef

    2013-07-01

    Allergic contact dermatitis is a frequent inflammatory skin disease. The suspected diagnosis is based on clinical symptoms, a plausible contact to allergens and a suitable history of dermatitis. Differential diagnoses should be considered only after careful exclusion of any causal contact sensitization. Hence, careful diagnosis by patch testing is of great importance. Modifications of the standardized test procedure are the strip patch test and the repeated open application test. The interpretation of the SLS (sodium lauryl sulfate) patch test as well as testing with the patients' own products and working materials are potential sources of error. Accurate patch test reading is affected in particular by the experience and individual factors of the examiner. Therefore, a high degree of standardization and continuous quality control is necessary and may be supported by use of an online patch test reading course made available by the German Contact Dermatitis Research Group. A critical relevance assessment of allergic patch test reactions helps to avoid relapses and the consideration of differential diagnoses. Any allergic test reaction should be documented in an allergy ID card including the INCI name, if appropriate. The diagnostics of allergic contact dermatitis is endangered by a seriously reduced financing of patch testing by the German statutory health insurances. Restrictive regulations by the German Drug Law block the approval of new contact allergens for routine patch testing. Beside the consistent avoidance of allergen contact, temporary use of systemic and topical corticosteroids is the therapy of first choice.

  6. Multilaboratory Comparison of Proficiencies in Susceptibility Testing of Helicobacter pylori and Correlation between Agar Dilution and E Test Methods

    PubMed Central

    Best, L. M.; Haldane, D. J. M.; Keelan, M.; Taylor, D. E.; Thomson, A. B. R.; Loo, V.; Fallone, C. A.; Lyn, P.; Smaill, F. M.; Hunt, R.; Gaudreau, C.; Kennedy, J.; Alfa, M.; Pelletier, R.; Veldhuyzen van Zanten, S. J. O.

    2003-01-01

    Susceptibility testing was performed at seven Canadian microbiology laboratories and the Helicobacter Reference Laboratory, Halifax, Nova Scotia, Canada, to assess susceptibility testing proficiency and the reproducibility of the results for clarithromycin and metronidazole and to compare the Epsilometer test (E test) method to the agar dilution reference method. Control strain Helicobacter pylori ATCC 43504 (American Type Culture Collection) and 13 clinical isolates (plus duplicates of four of these strains including ATCC 43504) were tested blindly. The National Committee for Clinical Laboratory Standards (NCCLS) guidelines for agar dilution testing were followed, and the same suspension of organisms was used for agar dilution and E test. Antimicrobials and E test strips were provided to the investigators. Methods were provided on a website (www.Helicobactercanada.org). Each center reported MICs within the stated range for strain ATCC 43504. Compared to the average MICs, interlaboratory agreements within 2 log2 dilutions were 90% (range, 69 to 100%) for clarithromycin by agar dilution, with seven very major errors [VMEs], and 85% (range, 65 to 100%) by E test, with three VMEs. Interlaboratory agreements within 2 log2 dilutions were 83% (range, 50 to 100%) for metronidazole by agar dilution, with six VMEs and eight major errors (MEs), and 75% (range, 50 to 94%) by E test, with four VMEs and four MEs. At lower and higher concentrations of antibiotic, E test MICs were slightly different from agar dilution MICs, but these differences did not result in errors. When a standardized protocol based on NCCLS guidelines was used, most participants in this study correctly identified clarithromycin- and metronidazole-susceptible and -resistant strains of H. pylori 93% of the time by either the agar dilution or E test method, and the numbers of errors were relatively equivalent by both methods. PMID:14506021

  7. Multilaboratory comparison of proficiencies in susceptibility testing of Helicobacter pylori and correlation between agar dilution and E test methods.

    PubMed

    Best, L M; Haldane, D J M; Keelan, M; Taylor, D E; Thomson, A B R; Loo, V; Fallone, C A; Lyn, P; Smaill, F M; Hunt, R; Gaudreau, C; Kennedy, J; Alfa, M; Pelletier, R; Veldhuyzen Van Zanten, S J O

    2003-10-01

    Susceptibility testing was performed at seven Canadian microbiology laboratories and the Helicobacter Reference Laboratory, Halifax, Nova Scotia, Canada, to assess susceptibility testing proficiency and the reproducibility of the results for clarithromycin and metronidazole and to compare the Epsilometer test (E test) method to the agar dilution reference method. Control strain Helicobacter pylori ATCC 43504 (American Type Culture Collection) and 13 clinical isolates (plus duplicates of four of these strains including ATCC 43504) were tested blindly. The National Committee for Clinical Laboratory Standards (NCCLS) guidelines for agar dilution testing were followed, and the same suspension of organisms was used for agar dilution and E test. Antimicrobials and E test strips were provided to the investigators. Methods were provided on a website (www.Helicobactercanada.org). Each center reported MICs within the stated range for strain ATCC 43504. Compared to the average MICs, interlaboratory agreements within 2 log(2) dilutions were 90% (range, 69 to 100%) for clarithromycin by agar dilution, with seven very major errors [VMEs], and 85% (range, 65 to 100%) by E test, with three VMEs. Interlaboratory agreements within 2 log(2) dilutions were 83% (range, 50 to 100%) for metronidazole by agar dilution, with six VMEs and eight major errors (MEs), and 75% (range, 50 to 94%) by E test, with four VMEs and four MEs. At lower and higher concentrations of antibiotic, E test MICs were slightly different from agar dilution MICs, but these differences did not result in errors. When a standardized protocol based on NCCLS guidelines was used, most participants in this study correctly identified clarithromycin- and metronidazole-susceptible and -resistant strains of H. pylori 93% of the time by either the agar dilution or E test method, and the numbers of errors were relatively equivalent by both methods.

  8. Intermittent Plate Tectonics

    NASA Astrophysics Data System (ADS)

    Silver, P. G.; Behn, M. D.

    2006-12-01

    Intermittent Plate Tectonics A basic premise of Earth Science is that plate tectonics has been continuously operating since it began early in Earth's history. Yet, plate-tectonic theory itself, specifically the collisional phase of the Wilson Cycle, constitutes a process that is capable of stopping all plate motion. The plausibility of a plate-tectonic hiatus is most easily illustrated by considering the expected future of the present-day plate-tectonic configuration. Since the opening of the Atlantic at ~200 ma, the area of the Atlantic basin has been growing at the expense of the Pacific. If this trend continues, relative plate motion models predict that in ~350 my, the Pacific Ocean basin will effectively close leading to widespread continent-continent collisions. Since a continent-continent collision represents the termination of subduction locally, the accumulated effect of all collisions is to stop subduction globally. In this scenario, ridges would then stop spreading and young oceanic lithosphere would cool, reaching a steady-state thickness of 100 km in about 80 my, based on the properties of oceanic lithosphere today. This would constitute the stoppage of plate tectonics. The presumption that plate tectonics never stops in the face of continental collisions is equivalent to requiring that subduction flux is approximately constant through time, such that subduction initiation roughly balances subduction termination. Such a balance then raises several questions about the subduction initiation process. When and how does subduction initiate? Is there a detectible relationship between subduction cessation and subduction initiation? We can gain some guidance into these questions by examining the plate motion history over the last 200 my. Subduction initiation has occurred over the last 80 my in three intra- oceanic subduction zones: Aleutians, Marianas-Izu-Bonin and Tonga-Kermadec in the Pacific basin. In these cases, however, subduction initiation would not

  9. Nickel silicide for Ni/Cu contact mono-silicon solar cells

    NASA Astrophysics Data System (ADS)

    Min, Seon Kyu; Kim, Dong Ho; Lee, Soo Hong

    2013-07-01

    A solar cell contact needs to be as thin as possible and have high conductivity since a thick contact causes shading loss and reduced current. Plating is a very suitable method for making a metal contact, and nickel is a high conductivity metal which is easy to form into a contact using electroless plating. After the nickel is plated on the silicon substrate, the nickel contact should be fired in order to form nickel silicide. Nickel silicide is used for the seed layer of the Cu contact for silicon solar cells. In this study, we replaced the screen-printed contact of the Passivated Emitter Solar Cell (PESC) with a Ni/Cu contact that has a selective emitter. The nickel layer was used as the seed layer, adhesion layer, and Cu diffusion barrier. The main contact was formed by plating the copper. The firing conditions of a conventional furnace were varied in order to form nickel silicide. Consequently, we achieved the best solar cell efficiency of 18.15%.

  10. Telescopic vision contact lens

    NASA Astrophysics Data System (ADS)

    Tremblay, Eric J.; Beer, R. Dirk; Arianpour, Ashkan; Ford, Joseph E.

    2011-03-01

    We present the concept, optical design, and first proof of principle experimental results for a telescopic contact lens intended to become a visual aid for age-related macular degeneration (AMD), providing magnification to the user without surgery or external head-mounted optics. Our contact lens optical system can provide a combination of telescopic and non-magnified vision through two independent optical paths through the contact lens. The magnified optical path incorporates a telescopic arrangement of positive and negative annular concentric reflectors to achieve 2.8x - 3x magnification on the eye, while light passing through a central clear aperture provides unmagnified vision.

  11. Optical contacting of quartz

    NASA Technical Reports Server (NTRS)

    Payne, L. L.

    1982-01-01

    The strength of the bond between optically contacted quartz surfaces was investigated. The Gravity Probe-B (GP-B) experiment to test the theories of general relativity requires extremely precise measurements. The quartz components of the instruments to make these measurements must be held together in a very stable unit. Optical contacting is suggested as a possible method of joining these components. The fundamental forces involved in optical contacting are reviewed and relates calculations of these forces to the results obtained in experiments.

  12. Nuclear reactor alignment plate configuration

    SciTech Connect

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  13. Evaluation of Trans-Vag Broth, Colistin-Nalidixic Agar, and CHROMagar StrepB for Detection of Group B Streptococcus in Vaginal and Rectal Swabs from Pregnant Women in South Africa

    PubMed Central

    Kwatra, Gaurav; Madhi, Shabir A.; Cutland, Clare L.; Buchmann, Eckhart J.

    2013-01-01

    Maternal vaginal colonization with group B streptococcus (GBS) is a major risk factor for invasive GBS infection in newborns. The CDC-recommended method for detecting GBS colonization is to culture vaginal and rectal swabs in a selective broth followed by subculture on blood agar or a selective medium. A high incidence of antimicrobial resistance in the fecal microflora can compromise the recovery of GBS from the selective broth. Here, we compared CHROMagar StrepB (CA), Columbia colistin-nalidixic agar (CNA), and Trans-Vag selective broth enrichment for the isolation of GBS from 130 vaginal and 130 rectal swabs from pregnant women. The swabs were randomized for plating first on either CA or CNA, and they then were inoculated in Trans-Vag broth. GBS was cultured from 37.7% of the vaginal swabs and 33.1% of the rectal swabs. There were no differences in the detection rates for the vaginal swabs between CA (31.5%), CNA (26.2%), and the selective broth (30.0%). The sensitivities in relation to a composite score were 83.7%, 69.4%, and 79.6%, respectively. However, recovery of GBS from the rectal swabs was significantly higher from CA (29.2%; P < 0.0001) and CNA (23.8%; P = 0.002) than from the selective broth (9.2%). The sensitivities were 88.4%, 72.1%, and 27.9%, respectively. The order of plating on the solid medium was significant (P = 0.003), with GBS detection rates of 30.8% and 24.6% when swabs were plated first and second, respectively. These findings show that a selective broth is not suitable for the recovery of GBS from rectal swabs in settings such as ours, due to masking of the GBS colonies by persistent microflora. PMID:23698527

  14. The Plate Tectonics Project

    ERIC Educational Resources Information Center

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  15. Unitary plate electrode

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor); Clough, Thomas J. (Inventor); Josefowicz, Jack Y. (Inventor); Sibert, John W. (Inventor)

    1985-01-01

    The unitary electrode (10) comprises a porous sheet (12) of fiberglass the strands (14) of which contain a coating (16) of conductive tin oxide. The lower portion of the sheet contains a layer (18) of resin and the upper layer (20) contains lead dioxide forming a positive active electrode on an electrolyte-impervious layer. The strands (14) form a continuous conduction path through both layers (16, 18). Tin oxide is prevented from reduction by coating the surface of the plate facing the negative electrode with a conductive, impervious layer resistant to reduction such as a thin film (130) of lead or graphite filled resin adhered to the plate with a layer (31) of conductive adhesive. The plate (10) can be formed by casting a molten resin from kettle (60) onto a sheet of glass wool (56) overlying a sheet of lead foil and then applying positive active paste from hopper (64) into the upper layer (68). The plate can also be formed by passing an assembly of a sheet ( 80) of resin, a sheet (86) of sintered glass and a sheet (90) of lead between the nip (92) of heated rollers (93, 95) and then filling lead oxide into the pores (116) of the upper layer (118).

  16. Growth Plate Injuries

    MedlinePlus

    ... or crushed, the growth plate may close prematurely, forming a bony bridge or “bar.” The risk of ... this publication: James S. Panagis, M.D., M.P.H., NIAMS/NIH; R. Tracy Ballock, M.D., Case ...

  17. INL HIP Plate Fabrication

    SciTech Connect

    B. H. Park; C. R. Clark; J. F. Jue

    2010-02-01

    This document outlines the process used to bond monolithic fuel plates by Hot Isostatic Pressing (HIP). This method was developed at Idaho National Laboratory (INL) for the Reduced Enrichment for Research and Test Reactors (RERTR) program. These foils have been used in a number of irradiation experiments in support of the United States Global Threat Reduction Initiative (GTRI) program.

  18. Elastic contact mechanics: percolation of the contact area and fluid squeeze-out.

    PubMed

    Persson, B N J; Prodanov, N; Krick, B A; Rodriguez, N; Mulakaluri, N; Sawyer, W G; Mangiagalli, P

    2012-01-01

    The dynamics of fluid flow at the interface between elastic solids with rough surfaces depends sensitively on the area of real contact, in particular close to the percolation threshold, where an irregular network of narrow flow channels prevails. In this paper, numerical simulation and experimental results for the contact between elastic solids with isotropic and anisotropic surface roughness are compared with the predictions of a theory based on the Persson contact mechanics theory and the Bruggeman effective medium theory. The theory predictions are in good agreement with the experimental and numerical simulation results and the (small) deviation can be understood as a finite-size effect. The fluid squeeze-out at the interface between elastic solids with randomly rough surfaces is studied. We present results for such high contact pressures that the area of real contact percolates, giving rise to sealed-off domains with pressurized fluid at the interface. The theoretical predictions are compared to experimental data for a simple model system (a rubber block squeezed against a flat glass plate), and for prefilled syringes, where the rubber plunger stopper is lubricated by a high-viscosity silicon oil to ensure functionality of the delivery device. For the latter system we compare the breakloose (or static) friction, as a function of the time of stationary contact, to the theory prediction.

  19. Occupational Contact Dermatitis

    PubMed Central

    2008-01-01

    Occupational contact dermatitis accounts for 90% of all cases of work-related cutaneous disorders. It can be divided into irritant contact dermatitis, which occurs in 80% of cases, and allergic contact dermatitis. In most cases, both types will present as eczematous lesions on exposed parts of the body, notably the hands. Accurate diagnosis relies on meticulous history taking, thorough physical examination, careful reading of Material Safety Data Sheets to distinguish between irritants and allergens, and comprehensive patch testing to confirm or rule out allergic sensitization. This article reviews the pathogenesis and clinical manifestations of occupational contact dermatitis and provides diagnostic guidelines and a rational approach to management of these often frustrating cases. PMID:20525126

  20. SAM Technical Contacts

    EPA Pesticide Factsheets

    These technical contacts are available to help with questions regarding method deviations, modifications, sample problems or interferences, quality control requirements, the use of alternative methods, or the need to address analytes or sample types.

  1. Fragrance allergic contact dermatitis.

    PubMed

    Cheng, Judy; Zug, Kathryn A

    2014-01-01

    Fragrances are a common cause of allergic contact dermatitis in Europe and in North America. They can affect individuals at any age and elicit a spectrum of reactions from contact urticaria to systemic contact dermatitis. Growing recognition of the widespread use of fragrances in modern society has fueled attempts to prevent sensitization through improved allergen identification, labeling, and consumer education. This review provides an overview and update on fragrance allergy. Part 1 discusses the epidemiology and evaluation of suspected fragrance allergy. Part 2 reviews screening methods, emerging fragrance allergens, and management of patients with fragrance contact allergy. This review concludes by examining recent legislation on fragrances and suggesting potential additions to screening series to help prevent and detect fragrance allergy.

  2. Contact air abrasion.

    PubMed

    Porth, R

    1999-05-01

    The advantages of contact air abrasion techniques are readily apparent. The first, of course, is the greatly increased ease of use. Working with contact also tends to speed the learning curve by giving the process a more natural dental feel. In addition, as one becomes familiar with working with a dust stream, the potential for misdirecting the air flow is decreased. The future use of air abrasion for deep decay removal will make this the treatment of choice for the next millennium.

  3. Contact dermatitis complicating pinnaplasty.

    PubMed

    Singh-Ranger, G; Britto, J A; Sommerlad, B C

    2001-04-01

    Proflavine allergy is uncommon, occurring in approximately 6% of patients attending contact dermatitis clinics. Proflavine wool is used by many surgeons in the UK as a dressing that can be moulded to conform to the contours of a corrected prominent ear. It may have bacteriostatic properties. We present a case where contact dermatitis in response to proflavine developed after pinnaplasty. This caused diagnostic confusion, a lengthened hospital stay and an unsightly hypertrophic scar.

  4. The impact of contact

    NASA Astrophysics Data System (ADS)

    Finney, B.

    1986-10-01

    Scenarios of the impact on human society of radio contact with an extraterrestrial civilization are presented. Some believe that contact with advanced extraterrestrials would quickly devastate the human spirit, while others believe that these super-intelligent beings would show the inhabitants of the earth how to live in peace. It is proposed that the possible existence of extraterrestrial civilizations and the development of means of studying and communicating with them need to be considered.

  5. ELECTRIC CONTACT MEANS

    DOEpatents

    Grear, J.W. Jr.

    1959-03-10

    A switch adapted to maintain electrical connections under conditions of vibration or acceleration is described. According to the invention, thc switch includes a rotatable arm carrying a conductive bar arranged to close against two contacts spaced in the same plane. The firm and continuous engagement of the conductive bar with the contacts is acheived by utilizeing a spring located betwenn the vbar and athe a rem frzme and slidable mounting the bar in channel between two arms suspendef from the arm frame.

  6. Preparation and characterization of agar-based nanocomposite films reinforced with bimetallic (Ag-Cu) alloy nanoparticles.

    PubMed

    Arfat, Yasir Ali; Ahmed, Jasim; Jacob, Harsha

    2017-01-02

    Agar-based active nanocomposite films were prepared by incorporating silver-copper (Ag-Cu) alloy nanoparticles (NPs) (0.5-4wt%) into glycerol plasticized agar solution. Thermo-mechanical, morphological, structural, and optical properties of the nanocomposite films were characterized by texture analyzer, differential scanning calorimetry (DSC), scanning electron microscope (SEM), X-ray diffraction (XRD), Fourier transforms infrared (FTIR) spectroscopy, and surface color measurement. Tensile strength and the melting temperature of the film increased linearly with NPs loading concentration. Color, transparency and UV barrier properties of agar films were influenced by the reinforcement of Ag-Cu NPs. XRD analysis confirmed the crystalline structure of the Agar/Ag-Cu nanocomposite films, whereas the smoothness and the homogeneity of film surface strongly reduced as observed through the SEM. The nanocomposite films exhibited a profound antibacterial activity against both Gram-positive (Listeria monocytogenes) and Gram-negative (Salmonella enterica sv typhimurium) bacteria. Overall, the agar nanocomposite films could be used as packaging material for food preservation by controlling foodborne pathogens and spoilage bacteria.

  7. Infrared thermography analysis of thermal diffusion induced by RF magnetic field on agar phantoms loaded with magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Bante-Guerra, Jose; Macías, J. D.; Caballero-Aguilar, L.; Vales-Pinzón, C.; Alvarado-Gil, J. J.

    2013-02-01

    Recently, several treatments for fighting malignant tumors have been designed. However these procedures have well known inconveniences, depending on their applicability, tumor size and side effects, among others. Magnetic hyperthermia is a safe, non-invasive method for cancer therapy. This treatment is applied via elevation of target tissue temperature by dissipation of heat from Magnetic Nanoparticles (MNPs), previously located within the tumor. The induction of heat causes cell death and therefore the removal of the tumor. In this work the thermal diffusion in phantoms of agar loaded with magnetic nanoparticles (MNPs) is studied using the infrared thermography technique, which is widely used in biology/medicine (e.g. skin temperature mapping). Agar is one of the materials used to simulate different types of body tissues, these samples are known as "phantoms". Agar is of natural origin, low cost and high degree of biocompatibility. In this work the agar gel was embedded with MNPs by coprecipitation and placed in an alternating magnetic field radiation. As a consequence, the energy from the radiation source is dissipated as heat and then transferred from the MNP to the gel, increasing its temperature. For the temperature analysis, the samples of agar gel were stimulated by RF magnetic field generated by coils. Heating was measured with infrared thermography using a Thermovision A20M infrared camera. Thermographic images allowed obtaining the dependence of thermal diffusion in the phantom as a function of the magnitude of the applied RF magnetic field and the load of magnetic particles.

  8. Agar extraction from integrated multitrophic aquacultured Gracilaria vermiculophylla: evaluation of a microwave-assisted process using response surface methodology.

    PubMed

    Sousa, A M M; Alves, V D; Morais, S; Delerue-Matos, C; Gonçalves, M P

    2010-05-01

    Microwave-assisted extraction (MAE) of agar from Gracilaria vermiculophylla, produced in an integrated multitrophic aquaculture (IMTA) system, from Ria de Aveiro (northwestern Portugal), was tested and optimized using response surface methodology. The influence of the MAE operational parameters (extraction time, temperature, solvent volume and stirring speed) on the physical and chemical properties of agar (yield, gel strength, gelling and melting temperatures, as well as, sulphate and 3,6-anhydro-L-galactose contents) was evaluated in a 2(4) orthogonal composite design. The quality of the extracted agar compared favorably with the attained using traditional extraction (2 h at 85 degrees Celsius) while reducing drastically extraction time, solvent consumption and waste disposal requirements. Agar MAE optimum results were: an yield of 14.4 + or - 0.4%, a gel strength of 1331 + or - 51 g/cm(2), 40.7 + or - 0.2 degrees Celsius gelling temperature, 93.1 + or - 0.5 degrees Celsius melting temperature, 1.73 + or - 0.13% sulfate content and 39.4 + or - 0.3% 3,6-anhydro-L-galactose content. Furthermore, this study suggests the feasibility of the exploitation of G. vermiculophylla grew in IMTA systems for agar production.

  9. Evaluation of Albicans ID2 and Biggy agar for the isolation and direct identification of vaginal yeast isolates.

    PubMed

    Ilkit, Macit; Hilmioglu, Suleyha; Tasbakan, Meltem; Aydemir, Sohret

    2007-06-01

    In this study, 250 vaginal samples from patients with vulvovaginal candidosis were inoculated onto two chromogenic media, Albicans ID(2) and Biggy agar, as well as onto Sabouraud chloramphenicol agar, yielding a total of 63 yeast (25.2 %) on all three media. These strains were identified as Candida glabrata in 20 (31.8 %) samples, Candida albicans in 15 samples (23.8 %), Candida tropicalis in 10 samples (15.9 %), Candida krusei in five samples (7.9 %), Candida kefyr in five samples (7.9 %), Candida dubliniensis in four samples (6.3 %), Candida parapsilosis in two samples (3.2 %) and Candida guilliermondii in two samples (3.2 %). Mixed fungal cultures and bacterial growth or filamentous fungi were not detected on any of the selected media. The sensitivity and specificity of the Albicans ID(2) and Biggy agar with regard to the identification of C. albicans were 80.0 and 64.6 %, and 86.7 and 56.3 %, respectively. This study showed these two chromogenic media to be as effective as Sabouraud chloramphenicol agar with respect to fungal detection. However, neither Albicans ID(2) nor Biggy agar was sufficient for reliable differentiation of yeasts to the species level.

  10. Comparison of Mast Burkholderia Cepacia, Ashdown + Gentamicin, and Burkholderia Pseudomallei Selective Agar for the Selective Growth of Burkholderia Spp.

    PubMed

    Edler, Carola; Derschum, Henri; Köhler, Mirko; Neubauer, Heinrich; Frickmann, Hagen; Hagen, Ralf Matthias

    2017-03-01

    Reliable identification of pathogenic Burkholderia spp. like Burkholderia mallei and Burkholderia pseudomallei in clinical samples is desirable. Three different selective media were assessed for reliability and selectivity with various Burkholderia spp. and nontarget organisms. Mast Burkholderia cepacia agar, Ashdown + gentamicin agar, and B. pseudomallei selective agar were compared. A panel of 116 reference strains and well-characterized clinical isolates, comprising 30 B. pseudomallei, 20 B. mallei, 18 other Burkholderia spp., and 48 nontarget organisms, was used for this assessment. While all B. pseudomallei strains grew on all three tested selective agars, the other Burkholderia spp. showed a diverse growth pattern. Nontarget organisms, i.e., nonfermentative rod-shaped bacteria, other species, and yeasts, grew on all selective agars. Colony morphology did not allow unambiguous discrimination. While the assessed selective media reliably allowed the growth of a wide range of B. pseudomallei strains, growth of other Burkholderia spp. is only partially ensured. Growth of various nontarget organisms has to be considered. Therefore, the assessed media can only be used in combination with other confirmative tests in the diagnostic procedure for the screening for melioidosis or glanders.

  11. Comparison of Mast Burkholderia Cepacia, Ashdown + Gentamicin, and Burkholderia Pseudomallei Selective Agar for the Selective Growth of Burkholderia Spp.

    PubMed Central

    Edler, Carola; Derschum, Henri; Köhler, Mirko; Neubauer, Heinrich; Frickmann, Hagen; Hagen, Ralf Matthias

    2017-01-01

    Reliable identification of pathogenic Burkholderia spp. like Burkholderia mallei and Burkholderia pseudomallei in clinical samples is desirable. Three different selective media were assessed for reliability and selectivity with various Burkholderia spp. and nontarget organisms. Mast Burkholderia cepacia agar, Ashdown + gentamicin agar, and B. pseudomallei selective agar were compared. A panel of 116 reference strains and well-characterized clinical isolates, comprising 30 B. pseudomallei, 20 B. mallei, 18 other Burkholderia spp., and 48 nontarget organisms, was used for this assessment. While all B. pseudomallei strains grew on all three tested selective agars, the other Burkholderia spp. showed a diverse growth pattern. Nontarget organisms, i.e., nonfermentative rod-shaped bacteria, other species, and yeasts, grew on all selective agars. Colony morphology did not allow unambiguous discrimination. While the assessed selective media reliably allowed the growth of a wide range of B. pseudomallei strains, growth of other Burkholderia spp. is only partially ensured. Growth of various nontarget organisms has to be considered. Therefore, the assessed media can only be used in combination with other confirmative tests in the diagnostic procedure for the screening for melioidosis or glanders. PMID:28386468

  12. Lettuce contact allergy.

    PubMed

    Paulsen, Evy; Andersen, Klaus E

    2016-02-01

    Lettuce (Lactuca sativa L.) and its varieties are important vegetable crops worldwide. They are also well-known, rarely reported, causes of contact allergy. As lettuce allergens and extracts are not commercially available, the allergy may be underdiagnosed. The aims of this article are to present new data on lettuce contact allergy and review the literature. Lettuce is weakly allergenic, and occupational cases are mainly reported. Using aimed patch testing in Compositae-allergic patients, two recent Danish studies showed prevalence rates of positive lettuce reactions of 11% and 22%. The majority of cases are non-occupational, and may partly be caused by cross-reactivity. The sesquiterpene lactone mix seems to be a poor screening agent for lettuce contact allergy, as the prevalence of positive reactions is significantly higher in non-occupationally sensitized patients. Because of the easy degradability of lettuce allergens, it is recommended to patch test with freshly cut lettuce stem and supplement this with Compositae mix. As contact urticaria and protein contact dermatitis may present as dermatitis, it is important to perform prick-to-prick tests, and possibly scratch patch tests as well. Any person who is occupationally exposed to lettuce for longer periods, especially atopics, amateur gardeners, and persons keeping lettuce-eating pets, is potentially at risk of developing lettuce contact allergy.

  13. Contact Whiskers for Millimeter Wave Diodes

    NASA Technical Reports Server (NTRS)

    Kerr, A. R.; Grange, J. A.; Lichtenberger, J. A.

    1978-01-01

    Several techniques are investigated for making short conical tips on wires (whiskers) used for contacting millimeter-wave Schottky diodes. One procedure, using a phosphoric and chromic acid etching solution (PCE), is found to give good results on 12 microns phosphor-bronze wires. Full cone angles of 60 degrees-80 degrees are consistently obtained, compared with the 15 degrees-20 degrees angles obtained with the widely used sodium hydroxide etch. Methods are also described for cleaning, increasing the tip diameter (i.e. blunting), gold plating, and testing the contact resistance of the whiskers. The effects of the whisker tip shape on the electrical resistance, inductance, and capacitance of the whiskers are studied, and examples given for typical sets of parameters.

  14. Visualization of Thermal Distribution Caused by Focused Ultrasound Field in an Agar Phantom

    NASA Astrophysics Data System (ADS)

    Kim, Jungsoon; Kim, Moojoon; Ha, Kanglyeol

    2011-07-01

    Ultrasound waves have been widely used not only in medical diagnostic systems but also in medical treatment. There has been increasing interest in the thermal distribution caused by ultrasound waves. In this study, using thermochromic particles, a visualization method was suggested in a mimic phantom for organic materials. By blending various thermochromic particles with different critical temperatures, the thermal field distribution in the phantom could be observed. The effect of a concave-type ultrasound transducer on the temperature distribution in an agar phantom mixed with thermochromic particles was observed. The temperature distribution corresponded to changes in the brightness distribution of gray. It was confirmed that the thermal distribution pattern in the vicinity of the focal area varies with the time exposure to ultrasound waves.

  15. Evaluation of agar dilution and broth microdilution methods to determine the disinfectant susceptibility.

    PubMed

    Wu, Guoyan; Yang, Qianru; Long, Mei; Guo, Lijuan; Li, Bei; Meng, Yue; Zhang, Anyun; Wang, Hongning; Liu, Shuliang; Zou, Likou

    2015-11-01

    A variety of disinfectants have been widely used in veterinary hygiene, food industries and environments, which could induce the development of bacterial resistance to disinfectants. The methods used to investigate antimicrobial effects of disinfectant vary considerably among studies, making comparisons difficult. In this study, agar dilution and broth microdilution methods were used to compare the antimicrobial activities of four quaternary ammonium compounds (QACs) against foodborne and zoonotic pathogens. The potential relationship between the presence of QACs resistance genes and phenotypic resistance to QACs was also investigated. Our results indicated that the minimum inhibitory concentrations (MICs) determined by two methods might be different depended upon different QACs and bacteria applied. Regardless of the testing methods, Klebsiella pneumoniae was more tolerant among Gram-negative strains to four QACs, followed by Salmonella and Escherichia coli. The agreement between MICs obtained by the two methods was good, for benzalkonium chloride (78.15%), didecyldimethylammonium chloride (DDAC) (82.35%), cetylpyridinium chloride (CTPC) (97.48%) and cetyltrimethylammonium bromide (CTAB) (99.16%), respectively. Among all Gram-negative bacteria, 94.55% (n=52) of qacEΔ1-positive strains showed higher MICs (512 mg l(-1)) to CTAB. The qacEΔ1 gene was highly associated (P<0.05) with the high MICs of QACs (⩾512 mg l(-1)). In addition, DDAC remained as the most effective disinfectant against both Gram-positive and Gram-negative bacteria. This is the first study that compared the agar dilution and broth microdilution methods to assess the antimicrobial activity of QACs. The study demonstrated the need to standardize method that would be used in evaluating QACs antimicrobial properties in the future.

  16. Effect of storage at 4 degrees on prepared Salmonella/microsome test plates.

    PubMed

    Stanton, C A; Riley, S E; Garner, R C

    1984-09-01

    Salmonella/microsome soft-agar overlay ('Ames' test) plates were prepared using the previously published 'York' method. Plates treated with either added 3-methylcholanthrene (3MC) or 3,3'-dichlorobenzidine (DCB) and Aroclor-induced rat-liver S9 were stored at 4 degrees after preparation and removed at time intervals thereafter for incubation at 37 degrees. The number of 3MC-induced mutants in TA100 fell within 24 h of storage by 50% but then remained at this level until 96 h. Storage for a total of 336 h still showed some residual mono-oxygenase activity. On the other hand the ability to convert DCB to a mutagen for TA98 appeared to increase with storage, reaching a peak by 96 h. After this time the number of induced mutants fell until by 336 h the numbers were approximately equal to those plates which had not been stored in the cold.

  17. Acanthamoeba can be differentiated by the polymerase chain reaction and simple plating assays.

    PubMed

    Khan, N A; Jarroll, E L; Paget, T A

    2001-09-01

    Acanthamoeba are opportunistic pathogens with invasive and noninvasive species. For clinical purposes it is important to differentiate potentially pathogenic from nonpathogenic isolates. For the rapid and sensitive identification of Acanthamoeba at the genus level, we used a polymerase chain reaction (PCR)-based method which detected as few as five cells. Further, we tested nine isolates of Acanthamoeba for their ability to produce cytopathic effects (CPE) on corneal epithelial cells. On the basis of the results, Acanthamoeba were divided into pathogenic or nonpathogenic groups. However, because CPE assays are not available to every diagnostic laboratory, we developed a simple plating assay based on osmotolerance which correlated well with the CPE assays. Pathogenic Acanthamoeba showed growth on higher osmolarity (agar plates containing one molar mannitol), while growth of nonpathogens was inhibited on these plates. In conclusion, we have developed methods for the rapid identification and differentiation of Acanthamoeba.

  18. Nonlinear Viscous Waves Produced by AN Impulsively Moving Plate.

    NASA Astrophysics Data System (ADS)

    Yang, Shih-An.

    1989-12-01

    The free-surface flow generated by an impulsively accelerating, surface-piercing, vertical plate has been studied numerically as well as experimentally. The two -dimensional, unsteady Navier-Stokes equations are discretized using the finite-analytic scheme which incorporates the analytic solution into the locally linearized differential equations. The continuity equation and the dynamic boundary conditions on normal and tangential stresses at the free surface are applied to determine the pressure and two velocity components at the free surface. The kinematic boundary condition on the free surface provides the movement of the free surface. A series of experiments is carried out in an open channel with a constant water depth. The flat vertical plate is fixed on a towing carriage which is set off by suddenly dropping a weight bucket through a connecting steel cable in a pulley system. The free-surface profile ahead of the plate and the pressure distribution on the plate surface are measured. The agreement of the free -surface profile and the pressure distribution between the numerical results and the experimental measurements is fairly good. The mathematical singularity, which is predicted by the potential-flow theory, at the contact line between the plate and the free surface is not observed in the physical experiments. The flow field around the moving contact line is studied by applying the present numerical code. The contact angle between the free surface and the vertical plate is found to be very close to that formed by the free surface of a fluid contained in a rectangular tank which moves with the same constant acceleration. The velocity of the moving contact line is thereby derived as a function of the acceleration of the plate based on the principle of the conservation of mass. The propagation of waves produced by a moving plate along the channel is also investigated numerically. The propagation speed of generated waves is close to that of shallow-water waves

  19. What Are Growth Plate Injuries?

    MedlinePlus

    ... nih.gov November 2014 What Are Growth Plate Injuries? Fast Facts: An Easy-to-Read Series of Publications ... Some inherited disorders 1 What Are Growth Plate Injuries? Fast Facts: An Easy-to-Read Series of Publications ...

  20. Renewable liquid reflecting zone plate

    DOEpatents

    Toor, Arthur; Ryutov, Dmitri D.

    2003-12-09

    A renewable liquid reflecting zone plate. Electrodes are operatively connected to a dielectric liquid in a circular or other arrangement to produce a reflecting zone plate. A system for renewing the liquid uses a penetrable substrate.

  1. Inhibition of Aspergillus flavus on agar media and brown rice cereal bars using cold atmospheric plasma treatment.

    PubMed

    Suhem, Kitiya; Matan, Narumol; Nisoa, Mudtorlep; Matan, Nirundorn

    2013-02-01

    This study aimed to optimize the operating parameters of cold atmospheric plasma treatment to inhibit the growth of Aspergillus flavus on agar media and brown rice cereal bars. The effects of argon plasma jet treatment on the growth of A. flavus on malt extract agar (MEA) at powers of 20 W and 40 W with exposure times at 5, 15 and 25 min were studied using response surface methodology (RSM) with a central composite face-centered (CCF) design. Multiple regression analysis indicated that plasma treatment at 40 W for 25 min is most effective for inhibiting growth of A. flavus on the agar medium. On brown rice cereal bars, plasma powered at 40 W for 20 min was capable of giving protection against A. flavus growth for up to 20 days under storage conditions of 25°C and 100% RH. These results demonstrated the potential of cold atmospheric plasma jet treatment to control mold growth on various food products.

  2. Antimicrobial susceptibility of Erysipelothrix rhusiopathiae isolated from pigs in Southern Japan with a modified agar dilution method.

    PubMed

    Chuma, Takehisa; Kawamoto, Toshio; Shahada, Francis; Fujimoto, Hideki; Okamoto, Karoku

    2010-05-01

    The determination of antimicrobial minimum inhibitory concentration (MIC) in Erysipelothrix rhusiopathiae by using the agar dilution method has not been covered by the Clinical and Laboratory Institute (CLSI). Only the broth microdilution method has been outlined. This report describes a modification of the agar dilution procedure for E. rhusiopathiae using Trypto-soy agar supplemented with 0.1% Tween 80 and incubation in ambient air at 37 degrees C for 24 hr. The MICs of the assay were in agreement with those of the broth microdilution method recommended by the CLSI. Antimicrobial susceptibility test was performed using this method for 149 E. rhusiopathiae isolates from 2 meat processing plants in Kagoshima Prefecture during the period of April 2004 to March 2005. The number of strains resistant to oxytetracycline, erythromycin, lincomycin, ofloxacin and enrofloxacin were 56 (37.6%), 4 (2.7%), 18 (12.1%), 21 (14.1%) and 19 (12.8%), respectively. All strains were susceptible to ampicillin.

  3. Immune haemolysis in agar: demonstration of the protective action of antibodies

    PubMed Central

    Thompson, R. A.; Rowe, D. S.

    1967-01-01

    Certain human sera contain antibodies which under some circumstances inhibit complement dependent lysis of sensitized sheep cells. The activity of these antibodies was demonstrated by the use of agarose plates containing sensitized sheep cells. Most human sera placed in small holes cut in the plates produced homogeneous zones of total lysis around the holes. Occasional sera produced an inner zone of unlysed cells within an outer zone of lysis. Detailed studies of three such sera showed that this appearance was due to a protective effect of natural anti-sheep cell antibodies of IgG class. ImagesFIG. 1FIG. 2 PMID:6055754

  4. The contact caveat: negative contact predicts increased prejudice more than positive contact predicts reduced prejudice.

    PubMed

    Barlow, Fiona Kate; Paolini, Stefania; Pedersen, Anne; Hornsey, Matthew J; Radke, Helena R M; Harwood, Jake; Rubin, Mark; Sibley, Chris G

    2012-12-01

    Contact researchers have largely overlooked the potential for negative intergroup contact to increase prejudice. In Study 1, we tested the interaction between contact quantity and valence on prejudice toward Black Australians (n = 1,476), Muslim Australians (n = 173), and asylum seekers (n = 293). In all cases, the association between contact quantity and prejudice was moderated by its valence, with negative contact emerging as a stronger and more consistent predictor than positive contact. In Study 2, White Americans (n = 441) indicated how much positive and negative contact they had with Black Americans on separate measures. Although both quantity of positive and negative contact predicted racism and avoidance, negative contact was the stronger predictor. Furthermore, negative (but not positive) contact independently predicted suspicion about Barack Obama's birthplace. These results extend the contact hypothesis by issuing an important caveat: Negative contact may be more strongly associated with increased racism and discrimination than positive contact is with its reduction.

  5. The Micromechanics of the Moving Contact Line

    NASA Technical Reports Server (NTRS)

    Lichter, Seth

    1999-01-01

    A transient moving contact line is investigated experimentally. The dynamic interface shape between 20 and 800 microns from the contact line is compared with theory. A novel experiment is devised, in which the contact line is set into motion by electrically altering the solid-liquid surface tension gamma(sub SL). The contact line motion simulates that of spontaneous wetting along a vertical plate with a maximum capillary number Ca approx. = 4 x 10(exp -2). The images of the dynamic meniscus are analyzed as a funtion of Ca. For comparison, the steady-state hydrodynamic equation based on the creeping flow model in a wedge geometry and the three-region uniform perturbation expansion of Cox (1986) is adopted. The interface shape is well depicted by the uniform solutions for Ca <= 10(exp -3). However, for Ca > 10(exp -3), the uniform solution over-predicts the viscous bending. This over-prediction can be accounted for by modifying the slip coefficient within the intermediate solution. With this correction, the measured interface shape is seen to match the theoretical prediction for all capillary numbers. The amount of slip needed to fit the measurements does not scale with the capillary number.

  6. Focusing on Contact Lens Safety

    MedlinePlus

    ... Consumers Home For Consumers Consumer Updates Focusing on Contact Lens Safety Share Tweet Linkedin Pin it More ... substantial consumer injury. Back to top Types of Contact Lenses General categories Soft contact lenses. These are ...

  7. Enhanced chlorine resistance of tap water-adapted Legionella pneumophila as compared with agar medium-passaged strains.

    PubMed

    Kuchta, J M; States, S J; McGlaughlin, J E; Overmeyer, J H; Wadowsky, R M; McNamara, A M; Wolford, R S; Yee, R B

    1985-07-01

    Previous studies have shown that bacteria maintained in a low-nutrient "natural" environment such as swimming pool water are much more resistant to disinfection by various chemical agents than strains maintained on rich media. In the present study a comparison was made of the chlorine (Cl2) susceptibility of hot-water tank isolates of Legionella pneumophila maintained in tap water and strains passaged on either nonselective buffered charcoal-yeast extract or selective differential glycine-vancomycin-polymyxin agar medium. Our earlier work has shown that environmental and clinical isolates of L. pneumophila maintained on agar medium are much more resistant to Cl2 than coliforms are. Under the present experimental conditions (21 degrees C, pH 7.6 to 8.0, and 0.25 mg of free residual Cl2 per liter, we found the tap water-maintained L. pneumophila strains to be even more resistant than the agar-passaged isolates. Under these conditions, 99% kill of tap water-maintained strains of L. pneumophila was usually achieved within 60 to 90 min compared with 10 min for agar-passaged strains. Samples from plumbing fixtures in a hospital yielded legionellae which were "super"-chlorine resistant when assayed under natural conditions. After one agar passage their resistance dropped to levels of comparable strains which had not been previously exposed to additional chlorination. These studies more closely approximate natural conditions than our previous work and show that tap water-maintained L. pneumophila is even more resistant to Cl2 than its already resistant agar medium-passaged counterpart.

  8. Use of antireflection layers to avoid ghost plating on Ni/Cu plated crystalline silicon solar cells

    NASA Astrophysics Data System (ADS)

    Jeong, Myeong Sang; Choi, Sung Jin; Chang, Hyo Sik; In Lee, Jeong; Kang, Min Gu; Kim, Donghwan; Song, Hee-eun

    2016-03-01

    Screen printing is a method commonly used for making electrodes for crystalline silicon solar cells. Although the screen-printing method is fast and easy, screen-printed electrodes have a porous structure, high contact resistance, and low aspect ratio. On the other hand, plated electrodes have low contact resistance and narrow electrode width. Therefore, the plating method could be substituted for the screen-printing method in crystalline silicon solar cells. During the plating process, ghost plating can appear at the surface when the quality of the passivation layer is poor, causing an increase in the recombination rate. In this paper, light-induced plating was applied to the fabrication of electrodes, and various passivation layers were investigated to remove ghost plating in crystalline silicon solar cells. These included, (1) SiNx deposited by plasma-enhanced chemical vapor deposition (PECVD), (2) a double SiNx layer formed by PECVD, (3) a double layer with thermal silicon oxide and SiNx deposited by PECVD, and (4) a double layer comprising SiNx and SiOx formed by PECVD. For the plated solar cells, a laser was used to remove various antireflection coating (ARC) layers and phosphoric acid was spin-coated onto the doped silicon wafer prior to laser ablation. Also, a screen-printed solar cell was fabricated to compare plated solar cells with screen-printed solar cells. As a result, we found that a thermal SiO2/PECVD SiNx layer showed the lowest pinhole density and its wet vapor transmission rate was characterized. The solar cell with the thermal SiO2/PECVD SiNx layer showed the lowest J02 value, as well as improved Voc and Jsc.

  9. Microchannel plate streak camera

    DOEpatents

    Wang, Ching L.

    1989-01-01

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 KeV x-rays.

  10. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1985-01-01

    A liquid-impermeable plate (10) having throughplate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with lead spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  11. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1984-09-28

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (uv to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 keV x-rays.

  12. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1989-03-21

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras is disclosed. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1,000 KeV x-rays. 3 figs.

  13. Mechanisms in Thermal Mechanical Forming of Plates.

    DTIC Science & Technology

    1987-05-01

    specific locations within the plate is discussed, and recommendations for further research are made. Keywords: Metal plates; Ship plates; Material forming; Thermomechanics; Edge effect ; Laser line heating.

  14. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Reynolds, L.; Tweed, H.

    1972-01-01

    The work performed entailed the design, development, construction and testing of a 4000 word by 18 bit random access, NDRO plated wire memory for use in conjunction with a spacecraft imput/output unit and central processing unit. The primary design parameters, in order of importance, were high reliability, low power, volume and weight. A single memory unit, referred to as a qualification model, was delivered.

  15. Elastic plate spallation

    NASA Technical Reports Server (NTRS)

    Oline, L.; Medaglia, J.

    1972-01-01

    The dynamic finite element method was used to investigate elastic stress waves in a plate. Strain displacement and stress strain relations are discussed along with the stiffness and mass matrix. The results of studying point load, and distributed load over small, intermediate, and large radii are reported. The derivation of finite element matrices, and the derivation of lumped and consistent matrices for one dimensional problems with Laplace transfer solutions are included. The computer program JMMSPALL is also included.

  16. Martian plate tectonics

    NASA Astrophysics Data System (ADS)

    Sleep, N. H.

    1994-03-01

    The northern lowlands of Mars have been produced by plate tectonics. Preexisting old thick highland crust was subducted, while seafloor spreading produced thin lowland crust during late Noachian and Early Hesperian time. In the preferred reconstruction, a breakup margin extended north of Cimmeria Terra between Daedalia Planum and Isidis Planitia where the highland-lowland transition is relatively simple. South dipping subduction occured beneath Arabia Terra and east dipping subduction beneath Tharsis Montes and Tempe Terra. Lineations associated with Gordii Dorsum are attributed to ridge-parallel structures, while Phelegra Montes and Scandia Colles are interpreted as transfer-parallel structures or ridge-fault-fault triple junction tracks. Other than for these few features, there is little topographic roughness in the lowlands. Seafloor spreading, if it occurred, must have been relatively rapid. Quantitative estimates of spreading rate are obtained by considering the physics of seafloor spreading in the lower (approx. 0.4 g) gravity of Mars, the absence of vertical scarps from age differences across fracture zones, and the smooth axial topography. Crustal thickness at a given potential temperature in the mantle source region scales inversely with gravity. Thus, the velocity of the rough-smooth transition for axial topography also scales inversely with gravity. Plate reorganizations where young crust becomes difficult to subduct are another constraint on spreading age. Plate tectonics, if it occurred, dominated the thermal and stress history of the planet. A geochemical implication is that the lower gravity of Mars allows deeper hydrothermal circulation through cracks and hence more hydration of oceanic crust so that more water is easily subducted than on the Earth. Age and structural relationships from photogeology as well as median wavelength gravity anomalies across the now dead breakup and subduction margins are the data most likely to test and modify hypotheses

  17. Electronic Equipment Cold Plates

    DTIC Science & Technology

    1976-04-01

    equations for such a flow regiae. For laainar flow and Moderate teaperature differwwe« between the well «nd coolant, a aodifled Sieder -Tate...con- figuration. The heat-transfer coefficients, therefore, were determined by using both the Sieder -Tate and McAdams equations and the coaputed...values used In the analytical predictions. As with th* previous cold Plates, the Sieder -Tate equation gave too low of values for the heat- transfer

  18. The Plate Overlap Technique.

    DTIC Science & Technology

    1978-07-31

    INTRODUCTION 1 II. NOTATION 2 III. THE GNOMONIC PROJECTION 4 IV . THE PLATE OVERLAP TECHNIQUE 6 A. MOTIVATION 6 B. FORNULATION 9 C. ON STATISTICAL RIGOR 14 D...and new hardware. Since this aim was clearly recognized long ago, wherever possible in earlier documents or software development flexibility was...reader should see 1, 2, and 3. The procedures one should use to update stellar positions are discussed in 4 with applica- tions to the SAOC in 5. Non

  19. Plate motion and deformation

    SciTech Connect

    Minster, B.; Prescott, W.; Royden, L.

    1991-02-01

    Our goal is to understand the motions of the plates, the deformation along their boundaries and within their interiors, and the processes that control these tectonic phenomena. In the broadest terms, we must strive to understand the relationships of regional and local deformation to flow in the upper mantle and the rheological, thermal and density structure of the lithosphere. The essential data sets which we require to reach our goal consist of maps of current strain rates at the earth's surface and the distribution of integrated deformation through time as recorded in the geologic record. Our success will depend on the effective synthesis of crustal kinematics with a variety of other geological and geophysical data, within a quantitative theoretical framework describing processes in the earth's interior. Only in this way can we relate the snapshot of current motions and earth structure provided by geodetic and geophysical data with long-term processes operating on the time scales relevant to most geological processes. The wide-spread use of space-based techniques, coupled with traditional geological and geophysical data, promises a revolution in our understanding of the kinematics and dynamics of plate motions over a broad range of spatial and temporal scales and in a variety of geologic settings. The space-based techniques that best address problems in plate motion and deformation are precise space-geodetic positioning -- on land and on the seafloor -- and satellite acquisition of detailed altimetric and remote sensing data in oceanic and continental areas. The overall science objectives for the NASA Solid Earth Science plan for the 1990's, are to Understand the motion and deformation of the lithosphere within and across plate boundaries'', and to understand the dynamics of the mantle, the structure and evolution of the lithosphere, and the landforms that result from local and regional deformation. 57 refs., 7 figs., 2 tabs.

  20. Comparison of five plating media for isolation of Salmonella species from human stools.

    PubMed Central

    Ruiz, J; Nunez, M L; Diaz, J; Lorente, I; Perez, J; Gomez, J

    1996-01-01

    A comparative study was carried out to evaluate the performances of different culture media for the recovery of Salmonella spp. from 1,000 routine samples of human stools. By direct plating we tested Salmonella-Shigella agar (SS), Hektoen enteric agar (HE), bismuth sulfite agar (BS), novobiocin-brilliant green-glycerol-lactose agar (NBGL) and SM-ID medium (SM), and after selenite enrichment, we tested all of the media except HE. C8-esterase and oxidase tests were used for the screening of Salmonella spp. on SS and HE. The total number of Salmonella isolates from direct culture was 74, with respective sensitivities and positive predictive values (PPVs) of 78.4 and 61%, 64.9 and 18.7%, 36.5 and 34.2%, 55.4 and 20.7%, and 39.2 and 43.9% for NBGL, SS, HE, BS, and SMID, respectively. After enrichment, the total number of Salmonella isolates was 88. The respective sensitivities and PPVs obtained were 90.9 and 62.5%, 92 and 17%, 90.9 and 32% and 93.2 and 71.3% for NBGL, SS, BS, and SM, respectively. According to our results, NBGL in direct plating was the medium with the highest sensitivity with respect to the sensitivities of the other media, with significant statistical differences (P < 0.05). Likewise, the PPV for NBGL was also the highest (61%). After enrichment in selenite broth, the sensitivities of the four media tested were similar, with the best PPV obtained with SM (71.3%); this was followed by NBGL (62.5%). When C8-esterase was used on SS or HE, the PPVs improved from less than 40% to about 100%. PMID:8904438

  1. Armor Plate Surface Roughness Measurements

    DTIC Science & Technology

    2005-04-01

    Armor Plate Surface Roughness Measurements by Brian Stanton, William Coburn, and Thomas J. Pizzillo ARL-TR-3498 April 2005... Armor Plate Surface Roughness Measurements Brian Stanton, William Coburn and Thomas J. Pizzillo Sensors and Electron Devices Directorate...October 2004 5a. CONTRACT NUMBER 5b. GRANT NUMBER 4. TITLE AND SUBTITLE Armor Plate Surface Roughness Measurements 5c. PROGRAM ELEMENT NUMBER

  2. Criteria for the interpretation of the pipemidic acid agar diffusion test by the Kirby-Bauer method.

    PubMed

    Grimm, H

    1983-01-01

    The antibiotic sensitivity of 296 strains of Pseudomonas aeruginosa and 294 isolates of other species was measured by the agar diffusion test with 20 micrograms pipemidic acid (Deblaston) discs on Mueller-Hinton agar by the Kirby-Bauer method. The correlation between inhibition zone diameter and minimal inhibitory concentration was worked out by regression analysis. In all bacterial species investigated, an inhibition zone of 14 mm or more indicates sensitivity to pipemidic acid. For Pseudomonas aeruginosa an intermediate zone of 11 to 13 mm is recommended.

  3. A new method to assess temporal features of gait initiation with a single force plate.

    PubMed

    Moineau, Bastien; Boisgontier, Matthieu P; Barbieri, Guillaume; Nougier, Vincent

    2014-01-01

    The aim of this study was to investigate whether time of toe-off and heel-contact during gait initiation could be assessed with a single force plate. Twenty subjects performed ten self-paced gait initiations and seven other subjects performed ten gait initiations in four new conditions (slow, fast, obstacle and splint). Several force-plate parameters were measured with a single force plate, and actual toe-off and heel-contact were assessed with a motion analysis system. Results showed strong temporal correlations and closeness (r=.86-.99, mean error=3-86 ms) between two force-plate parameters and the kinematics events (toe-off and heel-contact). These new parameters may be of interest to easily measure duration of anticipatory postural adjustments and swing phase during clinical assessments.

  4. Metal bipolar plates for PEM fuel cell-A review

    NASA Astrophysics Data System (ADS)

    Tawfik, H.; Hung, Y.; Mahajan, D.

    The polymer electrolyte membrane (PEM) based fuel cells are clean alternative energy systems that hold excellent potential for cost effectiveness, durability, and relatively high overall efficiency. PEM fuel cell is recognized by the U.S. Department of Energy (DOE) as the main candidate to replace the internal combustion engine in transportation applications. Metallic bipolar plates and membrane electrode assembly (MEA) are two crucial components of a PEM power stack and their durability and fabrication cost must be optimized to allow fuel cells to penetrate the commercial market and compete with other energy sources. The bipolar plates perform as the current conductors between cells, provide conduits for reactant gases flow, and constitute the backbone of a power stack. They are commonly made of graphite composite for high corrosion resistance and good surface contact resistance; however their manufacturability, permeability, and durability for shock and vibration are unfavorable in comparison to metals. On the other hand, various methods and techniques must be developed to combat metallic corrosion and eliminate the passive layer that causes unacceptable reduction in contact resistance and possible fouling of the catalyst and the ionomer. Thus recently metallic bipolar plates have received considerable attention in the research community. This paper offers a comprehensive review of the research work conducted on metal bipolar plates to prevent corrosion while maintaining a low contact resistance.

  5. Gold nanowires fabricated by immersion plating.

    PubMed

    Hsu, Chih-Chieh; Shen, Fang-Yee; Huang, Fon-Shan

    2008-05-14

    The growth mechanism of oriented Au nanowires fabricated by immersion plating was investigated. Both n-type crystal Si (c-Si) and amorphous Si (a-Si) with an electron-beam (E-beam) patterned resist nanotrench were immersed into the plating bath HAuCl(4)/HF. For the Au nanowires fabricated on c-Si, voids, nanograins, and clusters were observed at various plating conditions, time and temperature. The voids were often found in the center of the Au nanowires due to there being fewer nucleation sites on the c-Si surface. However, Au can easily nucleate on the surface of a-Si and form continuous Au nanowires with grain sizes about 10-50 nm. The resistivities of Au nanowires with width 105 nm fabricated on a-Si are about 4.4-6.5 µΩ cm. After annealing at 200 °C for 30 min in N(2) ambient, the resistivities are lowered to about 3.0-3.9 µΩ cm, measured in an atomic force microscope (AFM) in contact mode. The grain size of Au is in the range of ∼50-100 nm. A scanning electron microscope (SEM) examination and grazing incident x-ray diffraction (GIXRD) analysis were also carried out to study the morphology and crystalline structure of the Au nanowires.

  6. Allergic contact dermatitis.

    PubMed

    Alikhan, Ali; Maibach, Howard I

    2014-01-01

    Allergic contact dermatitis is one of the most important dermatologic disorders worldwide - it can cause significant morbidity and decreased quality of life, as well as having major economic implications and loss of vocational productivity. Patch testing is the most important discovery in allergic contact dermatitis and the best diagnostic modality to date; the thin-layer rapid- use epicutaneous (TRUE) test is a more recent patch test development which has improved the convenience and feasibility of the test. The future of allergic contact dermatitis is bright as we continue to learn more about the science of the disorder, as well as ways to improve diagnosis and patient care. Furthermore, it is important to remember, in this global age, that cooperation between health care providers worldwide is essential.

  7. [Contact glass tonometer].

    PubMed

    Kanngiesser, H; Robert, Y; Dekker, P

    1996-10-01

    This paper present a tonometer incorporated in a contact lens, which allows simultaneous measurement of intraocular pressure and performance ophthalmoscopy. The tonometer can record the pulse curve continuously, which can give us an indication of any circulatory problem. The device is therefore expected to yield additional information useful for the diagnosis of early glaucoma. Te device has three force sensors built in, which allow continuous measurement of the force exerted on the eye surface by the contact lens. The force of the contact lens on the eye can be altered and makes the adjustment of different eye pressures possible. These induced changes of the eye pressure and their influence on the fundus can be checked. We have taken some measurements on enucleated human eyes to compare our device with a Statham tansducer in the vitreous. We found a good correlation. We are currently taking measurements in volunteers. The clinical relevance of these observations and measurements will be examined in a future study.

  8. Shoe allergic contact dermatitis.

    PubMed

    Matthys, Erin; Zahir, Amir; Ehrlich, Alison

    2014-01-01

    Foot dermatitis is a widespread condition, affecting men and women of all ages. Because of the location, this condition may present as a debilitating problem to those who have it. Allergic contact dermatitis involving the feet is frequently due to shoes or socks. The allergens that cause shoe dermatitis can be found in any constituent of footwear, including rubber, adhesives, leather, dyes, metals, and medicaments. The goal of treatment is to identify and minimize contact with the offending allergen(s). The lack of product information released from shoe manufacturers and the continually changing trends in footwear present a challenge in treating this condition. The aim of this study is to review the current literature on allergic contact shoe dermatitis; clinical presentation, allergens, patch testing, and management will be discussed. PubMed and MEDLINE databases were used for the search, with a focus on literature updates from the last 15 years.

  9. Acrylate Systemic Contact Dermatitis.

    PubMed

    Sauder, Maxwell B; Pratt, Melanie D

    2015-01-01

    Acrylates, the 2012 American Contact Dermatitis Society allergen of the year, are found in a range of products including the absorbent materials within feminine hygiene pads. When fully polymerized, acrylates are nonimmunogenic; however, if not completely cured, the monomers can be potent allergens.A 28-year-old woman is presented, who had her teeth varnished with Isodan (Septodont, Saint-Maur-des-Fossés, France) containing HEMA (2-hydroxyethyl methacrylate) with no initial reaction. Approximately 1 month later, the patient developed a genital dermatitis secondary to her feminine hygiene pads. The initial reaction resolved, but 5 months later, the patient developed a systemic contact dermatitis after receiving a second varnishing.The patient was dramatically patch test positive to many acrylates. This case demonstrates a reaction to likely unpolymerized acrylates within a feminine hygiene pad, as well as broad cross-reactivity or cosensitivity to acrylates, and possibly a systemic contact dermatitis with systemic re-exposure to unpolymerized acrylates.

  10. Origin of Small Tectonic Plates

    NASA Astrophysics Data System (ADS)

    Mallard, C.; Coltice, N.; Seton, M.; Müller, D.; Tackley, P.

    2015-12-01

    The plate tectonic theory allowed to split the Earth surface into 6 (Le Pichon 1968) to 52 tectonic plates (Bird 2003). These plates are separated into two groups: the first of 7 large plates and the second of numerous smaller plates (Morra et al 2013). Previous studies using the reconstruction of the past 200 My, suggest that the size of large plates is driven by mantle flow. But the tools employed are descriptive (Morra et al 2013, Sornette and Pisarenko 2003), hence ignoring forces and physical principles within the lithosphere and the mantle. The processes at the origin of small plates remain unknown. We developed a new approach to explain the plate sizes. We demonstrate that the physics of convection drives it. We applied plate tectonics theory on 3D spherical convection models generating plate-like motions, which give access to a complete survey of data: velocities, viscosity and heat flow. Our data show that (1) the large plates depend on the dominating scale of the convective flow due to the initiation or the shutdown of subductions; (2) the smaller plates are generated thanks to large variability of regional stresses along subduction zone by slab pull and suction influenced by the geometry of trenches. Our results are consistent with the quick reorganizations of back-arc basins occuring synchronously with the modification of subduction zones geometry around the Pacific plate (Sdrolias et al 2004). Hence, we conclude that (1) the decreasing number of small plates in the plate reconstructions back in time is an artifact induced by their short lifetime, that is why they are artificially ignored; (2) the geometry of past trenches is simplified leading to an underestimation of the length of subduction zones.

  11. Nickel release from nickel-plated metals and stainless steels.

    PubMed

    Haudrechy, P; Foussereau, J; Mantout, B; Baroux, B

    1994-10-01

    Nickel release from nickel-plated metals often induces allergic contact dermatitis, but, for nickel-containing stainless steels, the effect is not well-known. In this paper, AISI 304, 316L, 303 and 430 type stainless steels, nickel and nickel-plated materials were investigated. 4 tests were performed: patch tests, leaching experiments, dimethylglyoxime (DMG) spot tests and electrochemical tests. Patch tests showed that 96% of the patients were intolerant to Ni-plated samples, and 14% to a high-sulfur stainless steel (303), while nickel-containing stainless steels with a low sulfur content elicited no reactions. Leaching experiments confirmed the patch tests: in acidic artificial sweat, Ni-plated samples released about 100 micrograms/cm2/week of nickel, while low-sulfur stainless steels released less than 0.03 microgram/cm2/week of nickel, and AISI 303 about 1.5 micrograms/cm2/week. Attention is drawn to the irrelevance of the DMG spot test, which reveals Ni present in the metal bulk but not its dissolution rate. Electrochemical experiments showed that 304 and 316 grades remain passive in the environments tested, while Ni-plated steels and AISI 303 can suffer significant cation dissolution. Thus, Ni-containing 304 and 316 steels should not induce contact dermatitis, while 303 should be avoided. A reliable nitric acid spot test is proposed to distinguish this grade from other stainless steels.

  12. Compression behavior of delaminated composite plates

    NASA Technical Reports Server (NTRS)

    Peck, Scott O.; Springer, George S.

    1989-01-01

    The response of delaminated composite plates to compressive in-plane loads was investigated. The delaminated region may be either circular or elliptical, and may be located between any two plies of the laminate. For elliptical delaminations, the axes of the ellipse may be arbitrarily oriented with respect to the applied loads. A model was developed that describes the stresses, strains, and deformation of the sublaminate created by the delamination. The mathematical model is based on a two dimensional nonlinear plate theory that includes the effects of transverse shear deformation. The model takes into account thermal and moisture induced strains, transverse pressures acting on the sublaminate, and contact between the sublaminate and plate. The solution technique used is the Ritz method. A computationally efficient computer implementation of the model was developed. The code can be used to predict the nonlinear-load-strain behavior of the sublaminate including the buckling load, postbuckling behavior, and the onset of delamination growth. The accuracy of the code was evaluated by comparing the model results to benchmark analytical solutions. A series of experiments was conducted on Fiberite T300/976 graphite/epoxy laminates bonded to an aluminum honeycomb core forming a sandwich panel. Either circles or ellipses made from Teflon film were embedded in the laminates, simulating the presence of a delamination. Each specimen was loaded in compression and the strain history of the sublaminate was recorded far into the postbuckling regime. The extent of delamination growth was evaluated by C-scan examination of each specimen. The experimental data were compared to code predictions. The code was found to describe the data with reasonable accuracy. A sensitivity study examined the relative importance of various material properties, the delamination dimensions, the contact model, the transverse pressure differential, the critical strain energy release rate, and the relative

  13. Fourier-transform infrared study of the behavior of grease in lubricated contacts

    SciTech Connect

    Cann, P.M.; Spikes, H.A. )

    1992-04-01

    Changes in the structure (and thus the properties) of two grease lubricants (two different concentrations of lithium hydroxystearate soap thickener in a mineral oil), brought about by rubbing of greased contacts were investigated using infrared microspectroscopy. Comparisons are made of spectra obtained on rubbed surfaces out of contact and those directly within contacts during rubbing. Data on changes in the composition, the molecular alignment, and bonding of the various components of the lubricants, which resulted from shear were obtained using three experimental methods: the cone-on-plate method, the sliding EHD contact method of Cann and Spikes (1991) using FTIR spectroscopy, and a hydrodynamic contact method. 17 refs.

  14. Evaluation of a Test Article in the Salmonella typhimurium/Ecscherichia coli Plate Incorporation Mutation Assay in the Presence and Absence of Induced Rat Liver S-9. Test Article - Diethylene triamine trinitrate (DETN)

    DTIC Science & Technology

    2010-02-25

    the culture is required in order to be metabolized prior to plating . The Pre-Incubation method of treatment is perfonned at the request ofthe...Kalamazoo, Michigan. CULTURE CONDITIONS The cells were grown in Oxoid Nutrient Broth No.2 (Oxoid LTD, Hampshire, England) in a shaker incubator... aseptically placed in the center of the agar overlay. Ten ilL of a 1.0 mg/mL crystal violet solution was then added to the disc. The plates were

  15. Spa contact dermatitis.

    PubMed

    Yankura, Jessica A; Marks, James G; Anderson, Bryan E; Adams, David R

    2008-01-01

    Potassium monopersulfate (MPS) is widely used in spa and pool "shock" treatments, yet contact dermatitis associated with MPS has been rarely reported. A patient presented with a generalized scattered dermatitis from the neck down that worsened after spa use. Patch testing elicited a ++ reaction to ammonium persulfate. Contact with ammonium persulfate was ruled out; however, MPS, which can cross-react with ammonium persulfate, was found to be the active ingredient in the patient's spa shock treatments. The dermatitis cleared after the patient switched to a hydrogen peroxide-based shock treatment.

  16. Allergic Contact Dermatitis.

    PubMed

    Kostner, Lisa; Anzengruber, Florian; Guillod, Caroline; Recher, Mike; Schmid-Grendelmeier, Peter; Navarini, Alexander A

    2017-02-01

    Allergic contact dermatitis (ACD) is a common skin disease caused by a T cell-mediated immune reaction to usually innocuous allergens. ACD can have grave medical and socioeconomic consequences. ACD and irritant contact dermatitis often occur together. A detailed history and clinical examination are crucial and guide patch testing, which is the gold standard to diagnose ACD. T-cell clones persisting in the skin may explain the tendency of ACD to relapse even after years of allergen avoidance. Traditional treatments for ACD are topical steroids, calcineurin inhibitors, phototherapy, retinoids (including the recent alitretinoin), and immunosuppressants. Targeted therapies are lacking.

  17. Symmetries in laminated composite plates

    NASA Technical Reports Server (NTRS)

    Noor, A. K.

    1976-01-01

    The different types of symmetry exhibited by laminated anisotropic fibrous composite plates are identified and contrasted with the symmetries of isotropic and homogeneous orthotropic plates. The effects of variations in the fiber orientation and the stacking sequence of the layers on the symmetries exhibited by composite plates are discussed. Both the linear and geometrically nonlinear responses of the plates are considered. A simple procedure is presented for exploiting the symmetries in the finite element analysis. Examples are given of square, skew and polygonal plates where use of symmetry concepts can significantly reduce the scope and cost of analysis.

  18. Model of waterlike fluid under confinement for hydrophobic and hydrophilic particle-plate interaction potentials.

    PubMed

    Krott, Leandro B; Barbosa, Marcia C

    2014-01-01

    Molecular dynamic simulations were employed to study a waterlike model confined between hydrophobic and hydrophilic plates. The phase behavior of this system is obtained for different distances between the plates and particle-plate potentials. For both hydrophobic and hydrophilic walls, there are the formation of layers. Crystallization occurs at lower temperature at the contact layer than at the middle layer. In addition, the melting temperature decreases as the plates become more hydrophobic. Similarly, the temperatures of maximum density and extremum diffusivity decrease with hydrophobicity.

  19. Screening and Crystallization Plates for Manual and High-throughput Protein Crystal Growth

    NASA Technical Reports Server (NTRS)

    Thorne, Robert E. (Inventor); Berejnov, Viatcheslav (Inventor); Kalinin, Yevgeniy (Inventor)

    2010-01-01

    In one embodiment, a crystallization and screening plate comprises a plurality of cells open at a top and a bottom, a frame that defines the cells in the plate, and at least two films. The first film seals a top of the plate and the second film seals a bottom of the plate. At least one of the films is patterned to strongly pin the contact lines of drops dispensed onto it, fixing their position and shape. The present invention also includes methods and other devices for manual and high-throughput protein crystal growth.

  20. Non-contact optoacoustic imaging with focused air-coupled transducers

    SciTech Connect

    Deán-Ben, X. Luís; Pang, Genny A.; Razansky, Daniel; Montero de Espinosa, Francisco

    2015-08-03

    Non-contact optoacoustic imaging employing raster-scanning of a spherically focused air-coupled ultrasound transducer is showcased herein. Optoacoustic excitation with laser fluence within the maximal permissible human exposure limits in the visible and near-infrared spectra is applied to objects with characteristic dimensions smaller than 1 mm and absorption properties representative of the whole blood at near-infrared wavelengths, and these signals are shown to be detectable without contact to the sample using an air-coupled transducer with reasonable signal averaging. Optoacoustic images of vessel-mimicking tubes embedded in an agar phantom captured with this non-contact sensing technique are also showcased. These initial results indicate that an air-coupled ultrasound detection approach can be suitable for non-contact biomedical imaging with optoacoustics.

  1. Enhancement by sodium chloride of the selectivity of thiosulfate citrate bile salts sucrose agar for isolating Vibrio cholerae biotype El Tor.

    PubMed Central

    Morris, G K; DeWitt, W E; Gangarosa, E J; McCormack, W M

    1976-01-01

    In this study we utilized the salt-tolerant characteristics of vibrios to develop a more selective medium by addition of NaCl to thiosulfate citrate bile salts sucrose (TCBS) agar. The effect of adding salt to TCBS agar varied greatly among brands of TCBS agar and between lots of the same brand. The addition of salt at concentrations as high as 1.5% (2.5% total NaCl) caused the inhibition of growth of three species of commonly encountered normal bowel flora and one strain of classical Vibrio cholerae but did not compromise the use of TCBS agar for isolation of V. cholerae biotype El Tor. PMID:965476

  2. Methicillin-Resistant Staphylococcus aureus (MRSA) Detection: Comparison of Two Molecular Methods (IDI-MRSA PCR Assay and GenoType MRSA Direct PCR Assay) with Three Selective MRSA Agars (MRSA ID, MRSASelect, and CHROMagar MRSA) for Use with Infection-Control Swabs▿

    PubMed Central

    van Hal, S. J.; Stark, D.; Lockwood, B.; Marriott, D.; Harkness, J.

    2007-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is an increasing problem. Rapid detection of MRSA-colonized patients has the potential to limit spread of the organism. We evaluated the sensitivities and specificities of MRSA detection by two molecular methods (IDI-MRSA PCR assay and GenoType MRSA Direct PCR assay) and three selective MRSA agars (MRSA ID, MRSASelect, and CHROMagar MRSA), using 205 (101 nasal, 52 groin, and 52 axillary samples) samples from consecutive known MRSA-infected and/or -colonized patients. All detection methods had higher MRSA detection rates for nasal swabs than for axillary and groin swabs. Detection of MRSA by IDI-MRSA was the most sensitive method, independent of the site (94% for nasal samples, 80% for nonnasal samples, and 90% overall). The sensitivities of the GenoType MRSA Direct assay and the MRSA ID, MRSASelect, and CHROMagar MRSA agars with nasal swabs were 70%, 72%, 68%, and 75%, respectively. All detection methods had high specificities (95 to 99%), independent of the swab site. Extended incubation for a further 24 h with selective MRSA agars increased the detection of MRSA, with a corresponding decline in specificity secondary to a significant increase in false-positive results. There was a noticeable difference in test performance of the GenoType MRSA Direct assay in detection of MRSA (28/38 samples [74%]) compared with detection of nonmultiresistant MRSA (17/31 samples [55%]) (susceptible to two or more non-β-lactam antibiotics). This was not observed with selective MRSA agar plates or IDI-MRSA. Although it is more expensive, in addition to rapid turnaround times of 2 to 4 h, IDI-MRSA offers greater detection of MRSA colonization, independent of the swab site, than do conventional selective agars and GenoType MRSA Direct. PMID:17537949

  3. Hypervelocity impact on shielded plates

    NASA Technical Reports Server (NTRS)

    Smith, James P.

    1993-01-01

    A ballistic limit equation for hypervelocity impact on thin plates is derived analytically. This equation applies to cases of impulsive impact on a plate that is protected by a multi-shock shield, and it is valid in the range of velocity above 6 km/s. Experimental tests were conducted at the NASA Johnson Space Center on square aluminum plates. Comparing the center deflections of these plates with the theoretical deflections of a rigid-plastic plate subjected to a blast load, one determines the dynamic yield strength of the plate material. The analysis is based on a theory for the expansion of the fragmented projectile and on a simple failure criterion. Curves are presented for the critical projectile radius versus the projectile velocity, and for the critical plate thickness versus the velocity. These curves are in good agreement with curves that have been generated empirically.

  4. International waste minimization approaches and policies to metal plating

    SciTech Connect

    1996-08-01

    This technical report on metal plating provides an industry overview, detailed descriptions of wastes generated by metal plating operations, known waste minimization methods employed or being development by the industry, and tools for evaluating pollution prevention opportunities. This document is also a review and evaluation of the relevant policies used by the United States and other organization for economic cooperation and development (OECD) member countries to promote or mandate waste minimization. Appendices include international policy approaches, implication and evaluation of policies, U.S. federal and state pollution prevention policy/plans, and a list of pollution prevention contacts.

  5. Thermal contact resistance across a copper-silicon interface

    SciTech Connect

    Khounsary, A.M.; Chojnowski, D.; Assoufid, L.; Worek, W.M.

    1997-10-01

    The issue of thermal contact resistance across metallic interfaces has been investigated for many situations over the past several decades. The application in the present case is contact cooling of high heat load optical substrates. High heat load x-ray mirrors and other optical components used at the Advanced Photon Source (APS) are either internally cooled or contact cooled. In the internally cooled mirrors, a coolant flows through passages configured in the optical substrate. In the contact-cooled case, cooling is provided by placing cooling plates in contact with the mirror to extract the heat. Here, an experimental setup to measure the thermal contact conductance across a silicon-copper (Si-Cu) interface is described, and the results obtained are presented. The resulting thermal contact resistance data are used in estimating the thermo-mechanical and optical performance of optical substrates cooled by interfaced copper cooling blocks. Several factors influence the heat transfer across solid interfaces. These include the material properties, interface pressure, flatness and roughness of the contacting surfaces, temperature, and interstitial material, if any. Results presented show the variation of thermal contact conductance as a function of applied interface pressure for a Cu-Si interface. Various interstitial materials investigated include indium foil, silver foil and a liquid eutectic (Ga-In-Sn). As expected, thermal contact resistance decreases as interface pressure increases, except in the case of the eutectic, in which it was nearly constant. The softer the interstitial material, the lower the thermal contact resistance. Liquid metal provides the lowest thermal contact resistance across the Cu-Si interface, followed by the indium foil, and then the silver foil.

  6. Have Confidence in Contact

    ERIC Educational Resources Information Center

    Crisp, Richard J.; Turner, Rhiannon N.

    2010-01-01

    In an article in the May-June 2009 "American Psychologist," we discussed a new approach to reducing prejudice and encouraging more positive intergroup relations (Crisp & Turner, 2009). We named the approach imagined intergroup contact and defined it as "the mental simulation of a social interaction with a member or members of an outgroup category"…

  7. Compact contacting device

    NASA Technical Reports Server (NTRS)

    Acharya, Arun (Inventor); Gottzmann, Christian F. (Inventor); Lockett, Michael J. (Inventor); Schneider, James S. (Inventor); Victor, Richard A. (Inventor); Zawierucha, Robert (Inventor)

    1994-01-01

    An apparatus comprising a rotatable mass of structured packing for mass or heat transfer between two contacting fluids of different densities wherein the packing mass is made up of corrugated sheets of involute shape relative to the axis of the packing mass and form a logarithmic spiral curved counter to the direction of rotation.

  8. Contact: Releasing the news

    NASA Astrophysics Data System (ADS)

    Pinotti, Roberto

    The problem of mass behavior after man's future contacts with other intelligences in the universe is not only a challenge for social scientists and political leaders all over the world, but also a cultural time bomb as well. In fact, since the impact of CETI (Contact with Extraterrestrial Intelligence) on human civilization, with its different cultures, might cause a serious socio-anthropological shock, a common and predetermined worldwide strategy is necessary in releasing the news after the contact, in order to keep possible manifestations of fear, panic and hysteria under control. An analysis of past studies in this field and of parallel historical situations as analogs suggests a definite "authority crisis" in the public as a direct consequence of an unexpected release of the news, involving a devastating "chain reaction" process (from both the psychological and sociological viewpoints) of anomie and maybe the collapse of today's society. The only way to prevent all this is to prepare the world's public opinion concerning contact before releasing the news, and to develop a long-term strategy through the combined efforts of scientists, political leaders, intelligence agencies and the mass media, in order to create the cultural conditions in which a confrontation with ETI won't affect mankind in a traumatic way. Definite roles and tasks in this multi-level model are suggested.

  9. Disproportionate Minority Contact.

    PubMed

    Fix, Rebecca L; Cyperski, Melissa A; Burkhart, Barry R

    2017-04-01

    The overrepresentation of racial/ethnic minorities within the criminal justice system relative to their population percentage, a phenomenon termed disproportionate minority contact, has been examined within general adult and adolescent offender populations; yet few studies have tested whether this phenomenon extends to juvenile sexual offenders (JSOs). In addition, few studies have examined whether offender race/ethnicity influences registration and notification requirements, which JSOs are subject to in some U.S. states. The present study assessed for disproportionate minority contact among general delinquent offenders and JSOs, meaning it aimed to test whether the criminal justice system treats those accused of sexual and non-sexual offenses differently by racial/ethnic group. Furthermore, racial/ethnic group differences in risk, legal classification, and sexual offending were examined for JSOs. Results indicated disproportionate minority contact was present among juveniles with non-sexual offenses and JSOs in Alabama. In addition, offense category and risk scores differed between African American and European American JSOs. Finally, registration classifications were predicted by offending characteristics, but not race/ethnicity. Implications and future directions regarding disproportionate minority contact among JSOs and social and legal policy affecting JSOs are discussed.

  10. Lubrication Of Nonconformal Contacts

    NASA Technical Reports Server (NTRS)

    Jeng, Yeau-Ren

    1991-01-01

    Report discusses advances in knowledge of lubrication of nonconformal contacts in bearings and other machine elements. Reviews previous developments in theory of lubrication, presents advances in theory of lubrication to determine minimum film thickness, and describes experiments designed to investigate one of regimes of lubrication for ball bearings.

  11. Thermal Contact Conductance

    NASA Technical Reports Server (NTRS)

    Salerno, Louis J.; Kittel, Peter

    1997-01-01

    The performance of cryogenic instruments is often a function of their operating temperature. Thus, designers of cryogenic instruments often are required to predict the operating temperature of each instrument they design. This requires accurate thermal models of cryogenic components which include the properties of the materials and assembly techniques used. When components are bolted or otherwise pressed together, a knowledge of the thermal performance of such joints are also needed. In some cases, the temperature drop across these joints represents a significant fraction of the total temperature difference between the instrument and its cooler. While extensive databases exist on the thermal properties of bulk materials, similar databases for pressed contacts do not. This has often lead to instrument designs that avoid pressed contacts or to the over-design of such joints at unnecessary expense. Although many people have made measurements of contact conductances at cryogenic temperatures, this data is often very narrow in scope and even more often it has not been published in an easily retrievable fashion, if published at all. This paper presents a summary of the limited pressed contact data available in the literature.

  12. Primary plate identification of group A beta-hemolytic streptococci utilizing a two-disk technique.

    PubMed Central

    Baron, E J; Gates, J W

    1979-01-01

    A two-disk system is described which allows primary plate identification of group A beta-hemolytic streptococci. Group A beta-hemolytic streptococci could be visualized on primary throat culture plates by using trimethoprim-sulfamethoxazole to inhibit normal flora. In the heavily inoculated area of Trypticase soy agar plates containing 5% sheep blood, a 25-microgram/ml trimethoprim-sulfamethoxazole disk was placed contiguous to a 0.04-U bacitracin disk. A total of 259 throat specimens were examined with this two-disk system. The swabs from these throat specimens were incubated in Todd-Hewitt broth. The bacterial pellet from the broths was stained by fluorescent antibody as a control. Of the cultures that were determined to be positive on the plates, 75% could be read unequivocally after overnight incubation, whereas the remaining 25% required subculture. The plates recovered 91% of the cultures which were considered as true positives by the broth-fluorescent-antibody technique. This method provided a significant savings in time compared with standard plate methods and in cost of materials compared with broth-fluorescent-antibody methods. This technique is particularly valuable for producing rapid results in laboratories where fluorescence microscopy would not be cost-effective. Images PMID:387811

  13. Choline chloride based ionic liquid analogues as tool for the fabrication of agar films with improved mechanical properties

    Technology Transfer Automated Retrieval System (TEKTRAN)

    In the present paper, we test the suitability of Choline-Cl/urea (DES-U) and Choline-Cl/glycerol (DES-G) eutectic mixtures at 1:2 molar ratios for the production of agar biodegradable films. A three-step process is proposed: pre-solubilization of polymer in DES followed by compression-molding and s...

  14. Intelligent pH indicator film composed of agar/potato starch and anthocyanin extracts from purple sweet potato.

    PubMed

    Choi, Inyoung; Lee, Jun Young; Lacroix, Monique; Han, Jaejoon

    2017-03-01

    A new colorimetric pH indicator film was developed using agar, potato starch, and natural dyes extracted from purple sweet potato, Ipomoea batatas. Both agar and potato starch are solid matrices used to immobilize natural dyes, anthocyanins. The ultraviolet-visible (UV-vis) spectrum of anthocyanin extract solutions and agar/potato starch films with anthocyanins showed color variations to different pH values (pH 2.0-10.0). Fourier transform infrared (FT-IR) and UV-vis region spectra showed compatibility between agar, starch, and anthocyanin extracts. Color variations of pH indicator films were measured by a colorimeter after immersion in different pH buffers. An application test was conducted for potential use as a meat spoilage sensor. The pH indicator films showed pH changes and spoilage point of pork samples, changing from red to green. Therefore, the developed pH indicator films could be used as a diagnostic tool for the detection of food spoilage.

  15. [An observation on the histological structure of Oncomelania hupensis soft tissue by agar-paraffin double-embedding method].

    PubMed

    Tan, Ping; Zhang, Jie; Li, Qing; Yu, Zhi-jun

    2014-12-01

    In order to study the histological structure of Oncomelania hupensis soft tissue, the fixed soft tissues of O. hupensis were pre-embedded in the agar and made blocks, then dehydrated, transparentized, immersed in paraffin, sectioned, and stained with haematoxylin-eosin (HE). Permanent slides of O. hupensis soft tissue were obtained. The histological structure of soft tissues was clear under the microscope.

  16. Rolling contact fatigue of various unfilled and fiber reinforced polymers

    NASA Astrophysics Data System (ADS)

    Almajid, Abdulhakim; Friedrich, Klaus

    2012-07-01

    The wear behavior of Polyamide 6 (PA6), Polyoxymethylene (POM), Polyetheretherketone (PEEK), and Polyparaphenylene (PPP) materials under rolling contact was investigated. The ball on plate principle, i.e. a steel ball (as counterpart) rolls on a polymer plate specimen in rotational or linear motion, was used. The results are shown for different stress parameters which vary by load (50 N up to 300 N) and testing time (up to 50 hours). Differences in surface fatigue mechanisms were illustrated by microscopic methods. The best performance was found for PEEK. All the neat polymers were superior to any reinforced versions of them.

  17. Contact-resistance process cliff

    NASA Technical Reports Server (NTRS)

    Pina, C. A.

    1985-01-01

    Several approaches were investigated to obtain a measure of the quality of the contact resistance between metal and a diffused or polysilicon layer. These approaches have included the use of both short and very long contact strings as well as arays of contacts with different sizes to determine the contact resistance process cliff. Results from these approaches are discussed.

  18. Shuttle plate braiding machine

    NASA Technical Reports Server (NTRS)

    Huey, Jr., Cecil O. (Inventor)

    1994-01-01

    A method and apparatus for moving yarn in a selected pattern to form a braided article. The apparatus includes a segmented grid of stationary support elements and a plurality of shuttles configured to carry yarn. The shuttles are supported for movement on the grid assembly and each shuttle includes a retractable plunger for engaging a reciprocating shuttle plate that moves below the grid assembly. Such engagement at selected times causes the shuttles to move about the grid assembly in a selected pattern to form a braided article of a particular geometry.

  19. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Carpenter, K. H.

    1974-01-01

    The design, construction, and test history of a 4096 word by 18 bit random access NDRO Plated Wire Memory for use in conjunction with a spacecraft input/output and central processing unit is reported. A technical and functional description is given along with diagrams illustrating layout and systems operation. Test data is shown on the procedures and results of system level and memory stack testing, and hybrid circuit screening. A comparison of the most significant physical and performance characteristics of the memory unit versus the specified requirements is also included.

  20. Light scattering sensor for real-time identification of Vibrio parahaemolyticus, V. vulnificus and V. cholera colonies on solid agar plates

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The three most common pathogenic species of Vibrio, V. cholerae, V. parahemolyticus and V. vulnificus, are of major concern as water- and food-borne pathogens because of an increasing incidence of water and seafood related outbreaks and illnesses worldwide. Current methods are time-consuming and req...