Science.gov

Sample records for agar plate method

  1. A modified agar plate method for detection of Strongyloides stercoralis.

    PubMed

    Koga, K; Kasuya, S; Khamboonruang, C; Sukhavat, K; Ieda, M; Takatsuka, N; Kita, K; Ohtomo, H

    1991-10-01

    The agar plate method is a new technique with high detection rates for coprological diagnosis of human strongyloidiasis. This report details modifications of the technique and establishes a standardized procedure. We recommend that all plates should be carefully observed using a microscope because macroscopic observation can lead to false negative results. It is also advisable to pour formalin solution directly into microscopically positive dishes to collect worms by sedimentation. This procedure enables one to observe worms otherwise hidden. Sealing dishes with adhesive tape prevents larvae from crawling out of the dishes, eliminating any possibility in the reduction of detection rates, and greatly improves the safety conditions for the technician performing the procedure. We consider the agar plate method to be superior to the filter paper method in detecting Strongyloides, and we believe that it will eventually become the technique of choice.

  2. Strongyloidiasis detected by the agar plate culture method among patients infected by HIV.

    PubMed

    Urdez-Hernández, E; Jiménez-Galán, S; Antonio-Manríquez, M; DE León-Juárez, E A; Terrazas-Estrada, J J; Hernández-García, M C; García-Zaldívar, P; Estrada-Aguilera, A

    1999-10-01

    To evaluate the rate of strongyloidiasis among HIV/AIDS patients, stools and duodenal juice were examined using the agar plate culture method. From January to June 1993, a total of 60 HIV/AIDS patients were required for duodenal aspirate and three serial samples of freshly passed stools. Stools and duodenal aspirate were dispensed on an agar plate culture; after incubation at 28 degrees C during 48 h, screening of plates was made at 10 x. The presence of furrows and worms of short buccal chamber and prominent genital primordium were positive for Strongyloides stercoralis. Most patients were men (91.7%); their mean age, of 33.9 years (SD +/- 10.6); their median CD4(+) T-cells count, of 105/microL (range of 12 to 646). S. stercoralis was detected in three patients (5%). In duodenal juice, the three patients showed the parasite, but in feces, only two (3.3%). In these two individuals, the worms were found in feces by agar culture and Faust's concentration method. The rate of S. stercoralis in feces of HIV/AIDS individuals (3.3%) by agar culture method was similar to that formerly reported from the general Mexican population (2.9%) using standard concentration procedures. Hence, in this immunocompromised population of a low prevalence city, there was no advantage to using an agar plate culture for strongyloidiasis.

  3. An Agar-Based Method for Plating Marine Protozoan Parasites of the Genus Perkinsus

    PubMed Central

    Cold, Emma R.; Freyria, Nastasia J.; Martínez Martínez, Joaquín; Fernández Robledo, José A.

    2016-01-01

    The genus Perkinsus includes protozoan parasites of mollusks responsible for losses in the aquaculture industry and hampering the recovery of natural shellfish beds worldwide, and they are a key taxon for understanding intracellular parasitism adaptations. The ability to propagate the parasite in liquid media, in the absence of the host, has been crucial for improving understanding of its biology; however, alternative techniques to grow the parasite are needed to explore other basic aspects of the Perkinsus spp. biology. We optimized a DME: Ham’s F12–5% FBS- containing solid agar medium for plating Perkinsus marinus. This solid medium supported trophozoite propagation both by binary fission and schizogony. Colonies were visible to the naked eye 17 days after plating. We tested the suitability of this method for several applications, including the following: 1) Subcloning P. marinus isolates: single discrete P. marinus colonies were obtained from DME: Ham’s F12–5% FBS– 0.75% agar plates, which could be further propagated in liquid medium; 2) Subcloning engineered Perkinsus mediterraneus MOE[MOE]: GFP by streaking cultures on plates; 3) Chemical susceptibility: Infusing the DME: Ham’s F12–5% FBS– 0.75% agar plates with triclosan resulted in inhibition of the parasite propagation in a dose-dependent manner. Altogether, our plating method has the potential for becoming a key tool for investigating diverse aspects of Perkinsus spp. biology, developing new molecular tools, and for biotechnological applications. PMID:27149378

  4. An Agar-Based Method for Plating Marine Protozoan Parasites of the Genus Perkinsus.

    PubMed

    Cold, Emma R; Freyria, Nastasia J; Martínez Martínez, Joaquín; Fernández Robledo, José A

    2016-01-01

    The genus Perkinsus includes protozoan parasites of mollusks responsible for losses in the aquaculture industry and hampering the recovery of natural shellfish beds worldwide, and they are a key taxon for understanding intracellular parasitism adaptations. The ability to propagate the parasite in liquid media, in the absence of the host, has been crucial for improving understanding of its biology; however, alternative techniques to grow the parasite are needed to explore other basic aspects of the Perkinsus spp. biology. We optimized a DME: Ham's F12-5% FBS- containing solid agar medium for plating Perkinsus marinus. This solid medium supported trophozoite propagation both by binary fission and schizogony. Colonies were visible to the naked eye 17 days after plating. We tested the suitability of this method for several applications, including the following: 1) Subcloning P. marinus isolates: single discrete P. marinus colonies were obtained from DME: Ham's F12-5% FBS- 0.75% agar plates, which could be further propagated in liquid medium; 2) Subcloning engineered Perkinsus mediterraneus MOE[MOE]: GFP by streaking cultures on plates; 3) Chemical susceptibility: Infusing the DME: Ham's F12-5% FBS- 0.75% agar plates with triclosan resulted in inhibition of the parasite propagation in a dose-dependent manner. Altogether, our plating method has the potential for becoming a key tool for investigating diverse aspects of Perkinsus spp. biology, developing new molecular tools, and for biotechnological applications.

  5. Comparison of agar-based methods for the isolation and enumeration of heterotrophic bacteria with the new multidose IDEXX SimPlate method.

    PubMed

    Vulindlu, M; Charlett, A; Surman, S; Lee, J V

    2004-01-01

    Pour and spread plates are the conventional methods of choice for the isolation and enumeration of heterotrophic microorganisms in treated water supplies. The tests are performed at 22 degrees C and 37 degrees C for 72 h and 48 h respectively. Counts at 22 degrees C are associated with pollution of water systems from external sources, while counts at 37 degrees C are used as an indication of treatment plant performance and the deterioration of the general quality of water. Conventional methods using Yeast Extract Agar for a pour plate and R2A agar for a spread plate were compared with the multidose IDEXX SimPlate method for the isolation and enumeration of heterotrophic bacteria in water. SimPlate gave a significantly higher count on average than the conventional methods. The R2A method showed the next highest count, being significantly higher than Yeast Extract Agar. In addition, unlike the pour and spread plate methods, SimPlate was easier to use, reduced labour, and the test results were far easier to read.

  6. Antiserum-agar plate method for simultaneous detection and direct isolation of Legionella species in clinical and environmental specimens.

    PubMed Central

    Janssen, W A; Hedlund, K W

    1982-01-01

    Colonies of Legionella pneumophila serotypes 1 through 6, L. micdadei, L. bozemanii, L. dumoffii, and L. gormanii, which were developed on filtered yeast extract agar containing polyvalent antiserum, were surrounded by distinct, specific precipitin rings. Images PMID:7050153

  7. Development of a selective agar plate for the detection of Campylobacter spp. in fresh produce.

    PubMed

    Yoo, Jin-Hee; Choi, Na-Young; Bae, Young-Min; Lee, Jung-Su; Lee, Sun-Young

    2014-10-17

    This study was conducted to develop a selective medium for the detection of Campylobacter spp. in fresh produce. Campylobacter spp. (n=4), non-Campylobacter (showing positive results on Campylobacter selective agar) strains (n=49) isolated from fresh produce, indicator bacteria (n=13), and spoilage bacteria isolated from fresh produce (n=15) were plated on four Campylobacter selective media. Bolton agar and modified charcoal cefoperazone deoxycholate agar (mCCDA) exhibited higher sensitivity for Campylobacter spp. than did Preston agar and Hunt agar, although certain non-Campylobacter strains isolated from fresh produce by using a selective agar isolation method, were still able to grow on Bolton agar and mCCDA. To inhibit the growth of non-Campylobacter strains, Bolton agar and mCCDA were supplemented with 5 antibiotics (rifampicin, polymyxin B, sodium metabisulfite, sodium pyruvate, ferrous sulfate) and the growth of Campylobacter spp. (n=7) and non-Campylobacter strains (n=44) was evaluated. Although Bolton agar supplemented with rifampicin (BR agar) exhibited a higher selectivity for Campylobacter spp. than did mCCDA supplemented with antibiotics, certain non-Campylobacter strains were still able to grow on BR agar (18.8%). When BR agar with various concentrations of sulfamethoxazole-trimethoprim were tested with Campylobacter spp. (n=8) and non-Campylobacter (n=7), sulfamethoxazole-trimethoprim was inhibitory against 3 of 7 non-Campylobacter strains. Finally, we validated the use of BR agar containing 50mg/L sulfamethoxazole (BRS agar) or 0.5mg/L ciprofloxacin (BRCS agar) and other selective agars for the detection of Campylobacter spp. in chicken and fresh produce. All chicken samples were positive for Campylobacter spp. when tested on mCCDA, BR agar, and BRS agar. In fresh produce samples, BRS agar exhibited the highest selectivity for Campylobacter spp., demonstrating its suitability for the detection of Campylobacter spp. in fresh produce.

  8. Membrane-assisted culture of fungal mycelium on agar plates for RNA extraction and pharmacological analyses.

    PubMed

    Lange, Mario; Müller, Carolin; Peiter, Edgar

    2014-05-15

    Fungal mycelium grown in liquid culture is easy to harvest for RNA extraction and gene expression analyses, but liquid cultures often develop rather heterogeneously. In contrast, growth of fungal mycelium on agar plates is highly reproducible. However, this biological material cannot be harvested easily for downstream analyses. This article describes a PVDF (polyvinylidene difluoride) membrane-assisted agar plate culture method that enables the harvest of mycelium grown on agar plates. This culture method leads to a strongly reduced variation in gene expression between biological replicates and requires less growth space as compared with liquid cultures.

  9. Hyperspectral imaging for detecting pathogens grown on agar plates

    NASA Astrophysics Data System (ADS)

    Yoon, Seung Chul; Lawrence, Kurt C.; Siragusa, Gregory R.; Line, John E.; Park, Bosoon; Windham, William R.

    2007-09-01

    This paper is concerned with the development of a hyperspectral imaging technique for detecting and identifying one of the most common foodborne pathogens, Campylobacter. Direct plating using agars is an effective tool for laboratory tests and analyses of microorganisms. The morphology (size, growth pattern, color, etc.) of colonies grown on agar plates has been widely used to tentatively differentiate organisms. However, it is sometimes difficult to differentiate target organisms like Campylobacters from other contaminants grown together on the same agar plates. A hyperspectral imaging system operating at the visible and near infrared (VNIR) spectral region from 400 nm to 900 nm was set up to measure spectral signatures of 17 different Campylobacter and non-Campylobacter subspecies. Protocols for culturing, imaging samples and for calibrating measured data were developed. The VNIR spectral library of all 17 organisms commonly encountered in poultry was established from calibrated hyperspectral images. A classification algorithm was developed to locate and identify Campylobacters, non-Campylobacter contaminants, and background agars with 99.29% accuracy. This research has a potential to be expanded to detect other pathogens grown on agar media.

  10. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  11. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  12. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  13. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  14. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  15. Development of hyperspectral imaging technique for salmonella enteritidis and typhimurium on agar plates

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Salmonella is a common cause of foodborne disease resulting from the consumption of contaminated food products. Although a direct plating method is widely used for presumptive positive screening of pathogenic Salmonella colonies on agar plates, it is labor-intensive, time-consuming and also prone to...

  16. Mass production of spores of lactic acid-producing Rhizopus oryzae NBRC 5384 on agar plate.

    PubMed

    Yamane, Tsuneo; Tanaka, Ryosuke

    2013-01-01

    Mass production of sporangiospores (spores) of Rhizopus oryzae NBRC 5384 (identical to NRRL 395 and ATCC 9363) on potato-dextrose-agar medium was studied aiming at starting its L(+)-lactic acid fermentation directly from spore inoculation. Various parameters including harvest time, sowed spore density, size of agar plate, height of air space, and incubation mode of plate (agar-on-bottom or agar-on-top) were studied. Ordinarily used shallow Petri dishes were found out to be unsuitable for the full growth of R. oryzae sporangiophores. In a very wide range of the sowed spore density, the smaller it was, the greater the number of the harvested spores was. It was also interesting to find out that R. oryzae grown downward vertically with a deep air space in an agar-on-top mode gave larger amount of spores than in an agar-on-bottom mode at 30°C for 7-day cultivation. Scale-up of the agar plate culture from 26.4 to 292 cm(2) was studied, resulting in the proportional relationship between the number of the harvested spores/plate and the plate area in the deep Petri dishes. The number of plates of 50 cm in diameter needed for 100 m(3) industrial submerged fermentation started directly from 2 × 10(5) spores/mL inoculum size was estimated as about 6, from which it was inferred that such a fermentation would be feasible. Designing a 50 cm plate and a method of spreading and collecting the spores were suggested. Bioprocess technological significance of the "full-scale industrial submerged fermentation started directly from spore inoculation omitting pre-culture" has been discussed.

  17. Increased sensitivity of routine laboratory detection of Strongyloides stercoralis and hookworm by agar-plate culture.

    PubMed

    Jongwutiwes, S; Charoenkorn, M; Sitthichareonchai, P; Akaraborvorn, P; Putaporntip, C

    1999-01-01

    The efficacy of agar-plate culture has been evaluated for the detection of Strongyloides stercoralis and hookworm, compared with direct smear, the formalin-ether sedimentation technique and the filter-paper method. Of 1085 stool samples from the routine laboratory service at King Chulalongkorn Memorial Hospital in Bangkok, 241 samples harboured S. stercoralis, 153 hookworm and 2 Rhabditis hominis. The recovery rate of S. stercoralis by agar-plate culture is significantly superior to the other methods (P < 0.005). The ratios of positive results from the methods used to the total number of S. stercoralis-positive cases were as follows: 1:1.03 by agar-plate culture, 1:1.85 by the filter-paper method, 1:1.98 by the sedimentation technique and 1:10.48 by direct stool smear. A similar trend of the efficacy ratio of each method was obtained for hookworm detection. The characteristic furrows left by hookworm larvae, and larvae and adults of S. stercoralis could be used for preliminary species identification. Daily search for furrows on agar plates for up to 6 consecutive days resulted in an increased sensitivity for diagnosis of both S. stercoralis and hookworm infections.

  18. Evaluation of an Automated Instrument for Inoculating and Spreading Samples onto Agar Plates.

    PubMed

    Glasson, J H; Guthrie, L H; Nielsen, D J; Bethell, F A

    2008-04-01

    The findings from a preliminary assessment of a new instrument designed for the inoculation and spreading of specimens for microbiological analysis onto agar plates are described. The study found that the instrument was able to select full or biplates from a number of input cassettes, each containing different agar types. Samples were then inoculated by the instrument onto the agar surfaces and spread by a novel plastic applicator. Following this, the instrument labeled the plates and sorted them into a number of specified output stations. It was found that the instrument was able to inoculate and spread samples over a greater proportion of the agar plate surface than the manual loop-to-plate method. As a consequence, up to 44% more usable colonies were produced per plate from clinical specimens and standard cultures. Viable counts showed that the instrument was able to detect as few as 10(2) CFU/ml in fluids and also facilitated the enumeration of organisms, particularly in specimens such as urine.

  19. Hyperspectral image reconstruction using RGB color for foodborne pathogen detection on agar plates

    NASA Astrophysics Data System (ADS)

    Yoon, Seung-Chul; Shin, Tae-Sung; Park, Bosoon; Lawrence, Kurt C.; Heitschmidt, Gerald W.

    2014-03-01

    This paper reports the latest development of a color vision technique for detecting colonies of foodborne pathogens grown on agar plates with a hyperspectral image classification model that was developed using full hyperspectral data. The hyperspectral classification model depended on reflectance spectra measured in the visible and near-infrared spectral range from 400 and 1,000 nm (473 narrow spectral bands). Multivariate regression methods were used to estimate and predict hyperspectral data from RGB color values. The six representative non-O157 Shiga-toxin producing Eschetichia coli (STEC) serogroups (O26, O45, O103, O111, O121, and O145) were grown on Rainbow agar plates. A line-scan pushbroom hyperspectral image sensor was used to scan 36 agar plates grown with pure STEC colonies at each plate. The 36 hyperspectral images of the agar plates were divided in half to create training and test sets. The mean Rsquared value for hyperspectral image estimation was about 0.98 in the spectral range between 400 and 700 nm for linear, quadratic and cubic polynomial regression models and the detection accuracy of the hyperspectral image classification model with the principal component analysis and k-nearest neighbors for the test set was up to 92% (99% with the original hyperspectral images). Thus, the results of the study suggested that color-based detection may be viable as a multispectral imaging solution without much loss of prediction accuracy compared to hyperspectral imaging.

  20. Automated agar plate streaker: a linear plater on Society for Biomolecular Sciences standard plates.

    PubMed

    King, Gregory W; Kath, Gary S; Siciliano, Sal; Simpson, Neal; Masurekar, Prakash; Sigmund, Jan; Polishook, Jon; Skwish, Stephen; Bills, Gerald; Genilloud, Olga; Peláez, Fernando; Martín, Jesus; Dufresne, Claude

    2006-09-01

    Several protocols for bacterial isolation and techniques for aerobic plate counting rely on the use of a spiral plater to deposit concentration gradients of microbial suspensions onto a circular agar plate to isolate colony growth. The advantage of applying a gradient of concentrations across the agar surface is that the original microbiological sample can be applied at a single concentration rather than as multiple serial dilutions. The spiral plater gradually dilutes the sample across a compact area and therefore saves time preparing dilutions and multiple agar plates. Commercial spiral platers are not automated and require manual sample loading. Dispensing of the sample volume and rate of gradients are often very limited in range. Furthermore, the spiral sample application cannot be used with rectangular microplates. Another limitation of commercial spiral platers is that they are useful only for dilute, filtered suspensions and cannot plate suspensions of coarse organic particles therefore precluding the use of many kinds of microorganism-containing substrata. An automated agar plate spreader capable of processing 99 rectangular microplates in unattended mode is described. This novel instrument is capable of dispensing discrete volumes of sample in a linear pattern. It can be programmed to dispense a sample suspense at a uniform application rate or across a decreasing concentration gradient.

  1. Predicting the growth situation of Pseudomonas aeruginosa on agar plates and meat stuffs using gas sensors

    NASA Astrophysics Data System (ADS)

    Gu, Xinzhe; Sun, Ye; Tu, Kang; Dong, Qingli; Pan, Leiqing

    2016-12-01

    A rapid method of predicting the growing situation of Pseudomonas aeruginosa is presented. Gas sensors were used to acquire volatile compounds generated by P. aeruginosa on agar plates and meat stuffs. Then, optimal sensors were selected to simulate P. aeruginosa growth using modified Logistic and Gompertz equations by odor changes. The results showed that the responses of S8 or S10 yielded high coefficients of determination (R2) of 0.89–0.99 and low root mean square errors (RMSE) of 0.06–0.17 for P. aeruginosa growth, fitting the models on the agar plate. The responses of S9, S4 and the first principal component of 10 sensors fit well with the growth of P. aeruginosa inoculated in meat stored at 4 °C and 20 °C, with R2 of 0.73–0.96 and RMSE of 0.25–1.38. The correlation coefficients between the fitting models, as measured by electronic nose responses, and the colony counts of P. aeruginosa were high, ranging from 0.882 to 0.996 for both plate and meat samples. Also, gas chromatography–mass spectrometry results indicated the presence of specific volatiles of P. aeruginosa on agar plates. This work demonstrated an acceptable feasibility of using gas sensors—a rapid, easy and nondestructive method for predicting P. aeruginosa growth.

  2. Predicting the growth situation of Pseudomonas aeruginosa on agar plates and meat stuffs using gas sensors

    PubMed Central

    Gu, Xinzhe; Sun, Ye; Tu, Kang; Dong, Qingli; Pan, Leiqing

    2016-01-01

    A rapid method of predicting the growing situation of Pseudomonas aeruginosa is presented. Gas sensors were used to acquire volatile compounds generated by P. aeruginosa on agar plates and meat stuffs. Then, optimal sensors were selected to simulate P. aeruginosa growth using modified Logistic and Gompertz equations by odor changes. The results showed that the responses of S8 or S10 yielded high coefficients of determination (R2) of 0.89–0.99 and low root mean square errors (RMSE) of 0.06–0.17 for P. aeruginosa growth, fitting the models on the agar plate. The responses of S9, S4 and the first principal component of 10 sensors fit well with the growth of P. aeruginosa inoculated in meat stored at 4 °C and 20 °C, with R2 of 0.73–0.96 and RMSE of 0.25–1.38. The correlation coefficients between the fitting models, as measured by electronic nose responses, and the colony counts of P. aeruginosa were high, ranging from 0.882 to 0.996 for both plate and meat samples. Also, gas chromatography–mass spectrometry results indicated the presence of specific volatiles of P. aeruginosa on agar plates. This work demonstrated an acceptable feasibility of using gas sensors—a rapid, easy and nondestructive method for predicting P. aeruginosa growth. PMID:27941841

  3. Application of Microbiological Method Direct Epifluorescence Filter Techique/Aerobic Plate Count Agar in the Identification of Irradiated Herbs and Spices

    PubMed Central

    Di Schiavi, Maria Teresa; Foti, Marina; Mosconi, Maria Cristina; Mattiolo, Giuseppina; Cavallina, Roberta

    2014-01-01

    Irradiation is a preservation technology used to improve the safety and hygienic quality of food. Aim of this study was to assess the applicability and validity of the microbiological screening method direct epifluorescence filter technique (DEFT)/aerobic plate count (APC) (EN 13783:2001) for the identification of irradiated herbs and spices. Tests on non-irradiated and irradiated samples of dried herbs and spices were performed. The method was based on the comparison of APC and count obtained using DEFT. In accordance with the standard reference, this method is not applicable to samples with APC<103 colony forming units (CFU)/g and this is its main limit. The results obtained in our laboratories showed that in 50% of cases of non-irradiated samples and in 96% of the samples treated with ionising radiation, the method was not applicable due to a value of CFU/g <103. PMID:27800348

  4. Simulation of Bacillus subtilis biofilm growth on agar plate by diffusion-reaction based continuum model

    NASA Astrophysics Data System (ADS)

    Zhang, Xianlong; Wang, Xiaoling; Nie, Kai; Li, Mingpeng; Sun, Qingping

    2016-08-01

    Various species of bacteria form highly organized spatially-structured aggregates known as biofilms. To understand how microenvironments impact biofilm growth dynamics, we propose a diffusion-reaction continuum model to simulate the formation of Bacillus subtilis biofilm on an agar plate. The extended finite element method combined with level set method are employed to perform the simulation, numerical results show the quantitative relationship between colony morphologies and nutrient depletion over time. Considering that the production of polysaccharide in wild-type cells may enhance biofilm spreading on the agar plate, we inoculate mutant colony incapable of producing polysaccharide to verify our results. Predictions of the glutamate source biofilm’s shape parameters agree with the experimental mutant colony better than that of glycerol source biofilm, suggesting that glutamate is rate limiting nutrient for Bacillus subtilis biofilm growth on agar plate, and the diffusion-limited is a better description to the experiment. In addition, we find that the diffusion time scale is of the same magnitude as growth process, and the common-employed quasi-steady approximation is not applicable here.

  5. Visualization of Biosurfactant Film Flow in a Bacillus subtilis Swarm Colony on an Agar Plate

    PubMed Central

    Kim, Kyunghoon; Kim, Jung Kyung

    2015-01-01

    Collective bacterial dynamics plays a crucial role in colony development. Although many research groups have studied the behavior of fluidic swarm colonies, the detailed mechanics of its motion remains elusive. Here, we developed a visualization method using submicron fluorescent beads for investigating the flow field in a thin layer of fluid that covers a Bacillus subtilis swarm colony growing on an agar plate. The beads were initially embedded in the agar plate and subsequently distributed spontaneously at the upper surface of the expanding colony. We conducted long-term live cell imaging of the B. subtilis colony using the fluorescent tracers, and obtained high-resolution velocity maps of microscale vortices in the swarm colony using particle image velocimetry. A distinct periodic fluctuation in the average speed and vorticity of flow in swarm colony was observed at the inner region of the colony, and correlated with the switch between bacterial swarming and growth phases. At the advancing edge of the colony, both the magnitudes of velocity and vorticity of flow in swarm colony were inversely correlated with the spreading speed of the swarm edge. The advanced imaging tool developed in this study would facilitate further understanding of the effect of micro vortices in swarm colony on the collective dynamics of bacteria. PMID:26343634

  6. Hyperspectral image reconstruction using RGB color for foodborne pathogen detection on agar plates

    Technology Transfer Automated Retrieval System (TEKTRAN)

    This paper reports the latest development of a color vision technique for detecting colonies of foodborne pathogens grown on agar plates with a hyperspectral image classification model that was developed using full hyperspectral data. The hyperspectral classification model depended on reflectance sp...

  7. Screening fungicides for use in fish culture: Evaluation of the agar plug transfer, cellophane transfer, and agar dilution methods

    USGS Publications Warehouse

    Bailey, Tom A.

    1983-01-01

    The reliability, reproducibility, and usefulness of three screening methods -- the cellophane transfer, the agar plug transfer, and the agar dilution -- to screen aquatic fungicides were evaluated. Achlya flagellata and Saprolegnia hypogyna were exposed to 1, 10, and 100 mg/L of malachite green to test each method. The cellophane transfer and agar plug transfer techniques had similar reliability and reproducibility in rating fungicidal activity, and were both superior to the agar dilution technique. The agar plug transfer and agar dilution techniques adequately projected in vivo activity of malachite green, but the cellophane transfer technique overestimated its activity. Overall, the agar plug transfer technique most accurately rated the activity of malachite green and was the easiest test to perform. It therefore appears to be the method of choice for testing aquatic fungicides.

  8. Enhancing Bioaerosol Sampling by Andersen Impactors Using Mineral-Oil-Spread Agar Plate

    PubMed Central

    Xu, Zhenqiang; Wei, Kai; Wu, Yan; Shen, Fangxia; Chen, Qi; Li, Mingzhen; Yao, Maosheng

    2013-01-01

    As a bioaerosol sampling standard, Andersen type impactor is widely used since its invention in 1950s, including the investigation of the anthrax attacks in the United States in 2001. However, its related problems such as impaction and desiccation stress as well as particle bounce have not been solved. Here, we improved its biological collection efficiencies by plating a mineral oil layer (100 µL) onto the agar plate. An Andersen six-stage sampler and a BioStage impactor were tested with mineral-oil-spread agar plates in collecting indoor and outdoor bacterial and fungal aerosols. The effects of sampling times (5, 10 and 20 min) were also studied using the BioStage impactor when sampling environmental bioaerosols as well as aerosolized Bacillus subtilis (G+) and Escherichia coli (G-). In addition, particle bounce reduction by mineral-oil-plate was also investigated using an optical particle counter (OPC). Experimental results revealed that use of mineral-oil-spread agar plate can substantially enhance culturable bioaerosol recoveries by Andersen type impactors (p-values<0.05). The recovery enhancement was shown to depend on bioaerosol size, type, sampling time and environment. In general, more enhancements (extra 20%) were observed for last stage of the Andersen six-stage samplers compared to the BioStage impactor for 10 min sampling. When sampling aerosolized B. subtilis, E. coli and environmental aerosols, the enhancement was shown to increase with increasing sampling time, ranging from 50% increase at 5 min to ∼100% at 20 min. OPC results indicated that use of mineral oil can effectively reduce the particle bounce with an average of 66% for 10 min sampling. Our work suggests that enhancements for fungal aerosols were primarily attributed to the reduced impaction stress, while for bacterial aerosols reduced impaction, desiccation and particle bounce played major roles. The developed technology can readily enhance the agar-based techniques including those high

  9. Enhancing bioaerosol sampling by Andersen impactors using mineral-oil-spread agar plate.

    PubMed

    Xu, Zhenqiang; Wei, Kai; Wu, Yan; Shen, Fangxia; Chen, Qi; Li, Mingzhen; Yao, Maosheng

    2013-01-01

    As a bioaerosol sampling standard, Andersen type impactor is widely used since its invention in 1950s, including the investigation of the anthrax attacks in the United States in 2001. However, its related problems such as impaction and desiccation stress as well as particle bounce have not been solved. Here, we improved its biological collection efficiencies by plating a mineral oil layer (100 µL) onto the agar plate. An Andersen six-stage sampler and a BioStage impactor were tested with mineral-oil-spread agar plates in collecting indoor and outdoor bacterial and fungal aerosols. The effects of sampling times (5, 10 and 20 min) were also studied using the BioStage impactor when sampling environmental bioaerosols as well as aerosolized Bacillus subtilis (G+) and Escherichia coli (G-). In addition, particle bounce reduction by mineral-oil-plate was also investigated using an optical particle counter (OPC). Experimental results revealed that use of mineral-oil-spread agar plate can substantially enhance culturable bioaerosol recoveries by Andersen type impactors (p-values<0.05). The recovery enhancement was shown to depend on bioaerosol size, type, sampling time and environment. In general, more enhancements (extra 20%) were observed for last stage of the Andersen six-stage samplers compared to the BioStage impactor for 10 min sampling. When sampling aerosolized B. subtilis, E. coli and environmental aerosols, the enhancement was shown to increase with increasing sampling time, ranging from 50% increase at 5 min to ∼100% at 20 min. OPC results indicated that use of mineral oil can effectively reduce the particle bounce with an average of 66% for 10 min sampling. Our work suggests that enhancements for fungal aerosols were primarily attributed to the reduced impaction stress, while for bacterial aerosols reduced impaction, desiccation and particle bounce played major roles. The developed technology can readily enhance the agar-based techniques including those high

  10. Aseptic laboratory techniques: plating methods.

    PubMed

    Sanders, Erin R

    2012-05-11

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: Perform plating procedures without contaminating media. Isolate single bacterial colonies by the streak-plating

  11. Aseptic Laboratory Techniques: Plating Methods

    PubMed Central

    Sanders, Erin R.

    2012-01-01

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: ● Perform plating procedures without contaminating media. ● Isolate single bacterial colonies by the

  12. Broth and agar hop-gradient plates used to evaluate the beer-spoilage potential of Lactobacillus and Pediococcus isolates.

    PubMed

    Haakensen, M; Schubert, A; Ziola, B

    2009-03-15

    Identification of the beer-spoilage Lactobacillus and Pediococcus bacteria has largely taken two approaches; identification of spoilage-associated genes or identification of specific species of bacteria regardless of ability to grow in beer. The problem with these two approaches is that they are either overly inclusive (i.e., detect all bacteria of a given species regardless of spoilage potential) or overly selective (i.e., rely upon individual, putative spoilage-associated genes). Our goal was to design a method to assess the ability of Lactobacillus and Pediococcus to spoil beer that is independent of speciation or genetic background. In searching for a method by which to differentiate between beer-spoilage bacteria and bacteria that cannot grow in beer, we explored the ability of lactobacilli and pediococci isolates to grow in the presence of varying concentrations of hop-compounds and ethanol in broth medium versus on agar medium. The best method for differentiating between bacteria that can grow in beer and bacteria that do not pose a threat as beer-spoilage organisms was found to be a hop-gradient agar plate containing ethanol. This hop-gradient agar plate technique provides a rapid and simple solution to the dilemma of assessing the ability of Lactobacillus and Pediococcus isolates to grow in beer, and provides new insights into the different strategies used by these bacteria to survive under the stringent conditions of beer.

  13. Method for Measuring Changes in Surface Tension on Agar

    PubMed Central

    Weisberg, David S.; Dworkin, Martin

    1983-01-01

    The surface tension of agar surfaces was determined by measuring the contact angles formed by drops of various hydrophobic liquids on the surface and then calculating the composite surface free energy function by solving a series of simultaneous equations derived from these data. This method was used to measure the change in the surface tension of agar produced by the addition of various concentrations of albumin. The resulting curve was typical of the effect of increasing concentrations of surfactants on surface tension. The method was compared with other methods of determining surface tension of solids, and it was concluded that the technique used here provided the most reliable results. PMID:16346273

  14. Agar plate freezing assay for the in situ selection of transformed ice nucleating bacteria.

    PubMed

    Anastassopoulos, Elias

    2006-10-01

    An agar plate freezing assay is described based on the incorporation of fluorescein dye in agar medium. Upon addition of fluorescein the medium becomes transparent. This facilitates the monitoring of the ice nucleation event in vivo and the subsequent in situ selection of transformed ice nucleating bacteria. In comparison with known assays for the screening of transformants, the proposed assay is very accurate and reproducible. It may be applied in environmental samples screening for ice nucleating organisms, or in cDNA or genomic libraries for identifying novel ice nucleation genes. It may also prove useful in comparative studies of the ice nucleation activity, e.g. in directed evolution experiments involving ice nucleation genes.

  15. The Resazurin-Agar Method - a Quick Test to Determine Water Quality

    NASA Astrophysics Data System (ADS)

    Huckfeldt, J.; Westphal, B.; Claußen, L.

    2015-12-01

    Rezasurin has been used as a smart tracer in stream ecosystems to indicate metabolic activity, specifically aerobic respiration by heterotrophic bacteria. Resazurin is a blue compound which is irreversibly reduced to the pink resorufin in the presence of aerobic bacteria. The degree and speed of colour change from blue to pink is a measure of the degree of oxygen consumption and thus an indirect indication of the concentration of aerobic bacteria in a given medium. A high concentration of bacteria in water indicates a bad water quality. In our work a method was developed using resazurin agar plates to find a quick and easy way for testing water quality and comparing concentrations of bacteria in freshwater and seawater samples. The theory was to concentrate bacteria from a defined volume of water sample onto polycarbonate filters (0.2 μm), which are then placed onto the resazurin agar plate. The presence of aerobic bacteria on the filter will reduce the resazurin in the agar and the compound changes its colour. First tests conducted with different dilutions of a pure culture of yoghurt bacteria showed promising results and confirmed the feasibility of the method. In a further assay, we used water samples from different water layers and different temperatures and were also able to observe differences in the concentration of bacteria, depending on these different environmental conditions.The assay was also successfully used with seawater samples, collected from 2 different stations at 3 different depths in the Baltic Sea (salinity=15). The discolouration of the plates showed good correlation with the oxygen concentrations in the water. The resazurin-agar plate method is economical and fast. Several samples could be investigated at the same time without sacrificing the reliability of the results. Thus it is a good pre-screening test for a quantitative evaluation of bacteria in a water sample.

  16. Evaluation of the Granada agar plate for detection of vaginal and rectal group B streptococci in pregnant women.

    PubMed

    Gil, E G; Rodríguez, M C; Bartolomé, R; Berjano, B; Cabero, L; Andreu, A

    1999-08-01

    Granada medium was evaluated for the detection of group B streptococci (GBS) in vaginal and rectal swabs compared with selective Columbia blood agar and selective Lim broth. From May 1996 to March 1998, 702 pregnant women (35 to 37 weeks of gestation) participated in this three-phase study; 103 (14.7%) of these women carried GBS. In the first phase of the experiment (n = 273 women), vaginorectal specimens were collected on the same swab; the sensitivities of Granada tube, selective Columbia blood agar, and Lim broth were 31.4, 94.3, and 74.3%, respectively. In the second and third phases (n = 429 women), vaginal and rectal specimens were collected separately; the sensitivities of Granada plate, selective Columbia blood agar, and Lim broth (subcultured at 4 h on selective Columbia agar in the second phase and at 18 to 24 h in Granada plate in the third phase) were 91.1, 83.9, and 75%, respectively, in the second phase and 88.5, 90.4, and 63.5%, respectively, in the third phase. There were no statistically significant differences in GBS recovery between the Granada agar plate and selective Columbia blood agar, but the Granada plate provided a clear advantage; the characteristic red-orange colonies produced overnight by GBS can be identified by the naked eye and is so specific that further identification is unnecessary. The use of the Granada tube and Lim broth did not result in increased isolation of GBS. In conclusion, the Granada agar plate is highly sensitive for detecting GBS in vaginal and rectal swabs from pregnant women and can provide results in 18 to 24 h.

  17. Evaluation of the Granada Agar Plate for Detection of Vaginal and Rectal Group B Streptococci in Pregnant Women

    PubMed Central

    Gil, E. García; Rodríguez, M. C.; Bartolomé, R.; Berjano, B.; Cabero, L.; Andreu, A.

    1999-01-01

    Granada medium was evaluated for the detection of group B streptococci (GBS) in vaginal and rectal swabs compared with selective Columbia blood agar and selective Lim broth. From May 1996 to March 1998, 702 pregnant women (35 to 37 weeks of gestation) participated in this three-phase study; 103 (14.7%) of these women carried GBS. In the first phase of the experiment (n = 273 women), vaginorectal specimens were collected on the same swab; the sensitivities of Granada tube, selective Columbia blood agar, and Lim broth were 31.4, 94.3, and 74.3%, respectively. In the second and third phases (n = 429 women), vaginal and rectal specimens were collected separately; the sensitivities of Granada plate, selective Columbia blood agar, and Lim broth (subcultured at 4 h on selective Columbia agar in the second phase and at 18 to 24 h in Granada plate in the third phase) were 91.1, 83.9, and 75%, respectively, in the second phase and 88.5, 90.4, and 63.5%, respectively, in the third phase. There were no statistically significant differences in GBS recovery between the Granada agar plate and selective Columbia blood agar, but the Granada plate provided a clear advantage; the characteristic red-orange colonies produced overnight by GBS can be identified by the naked eye and is so specific that further identification is unnecessary. The use of the Granada tube and Lim broth did not result in increased isolation of GBS. In conclusion, the Granada agar plate is highly sensitive for detecting GBS in vaginal and rectal swabs from pregnant women and can provide results in 18 to 24 h. PMID:10405415

  18. Trace Amounts of Furan-2-Carboxylic Acids Determine the Quality of Solid Agar Plates for Bacterial Culture

    PubMed Central

    Hara, Shintaro; Isoda, Reika; Tahvanainen, Teemu; Hashidoko, Yasuyuki

    2012-01-01

    Background Many investigators have recognised that a significant proportion of environmental bacteria exist in a viable but non-culturable state on agar plates, and some researchers have also noticed that some of such bacteria clearly recover their growth on matrices other than agar. However, the reason why agar is unsuitable for the growth of some bacteria has not been addressed. Methodology/Principal Findings According to the guide of a bioassay for swarming inhibition, we identified 5-hydroxymethylfuran-2-carboxylic acid (5-HMFA) and furan-2-carboxylic acid (FA) as factors that inhibit bacterial swarming and likely inhibit extracellular polysaccharide production on agar. The furan-2-carboxylic acids 5-HMFA and FA effectively inhibited the swarming and swimming of several environmental bacteria at concentrations of 1.8 and 2.3 µg L−1 (13 and 21 nmol L−1), respectively, which are equivalent to the concentrations of these compounds in 0.3% agar. On Luria-Bertani (LB) plates containing 1.0% agar that had been previously washed with MeOH, a mixture of 5-HMFA and FA in amounts equivalent to their original concentrations in the unwashed agar repressed the swarming of Escherichia coli K12 strain W3110, a representative swarming bacterium. Conclusions/Significance Agar that contains trace amounts of 5-HMFA and FA inhibits the proliferation of some slow-growing or difficult-to-culture bacteria on the plates, but it is useful for single colony isolation due to the ease of identification of swarmable bacteria as the non-swarmed colonies. PMID:22848437

  19. Plating methods, a survey

    NASA Technical Reports Server (NTRS)

    Berkowitz, J. B.; Emerson, N. H.

    1972-01-01

    Results are presented of a comprehensive search of the literature available, much of which has been generated by the research centers of NASA and its contractors, on plating and coating methods and techniques. Methods covered included: (1) electroplating from aqueous solutions; (2) electroplating from nonaqueous solutions; (3) electroplating from fused-salt baths; (4) electroforming; (5) electroless plating, immersion plating, and mirroring; (6) electroplating from gaseous plasmas; and (7) anodized films and conversion coatings.

  20. Solvent-tolerance of fungi located on an interface between an agar plate and an organic solvent.

    PubMed

    Oda, Shinobu; Sugitani, Ayaka; Ohashi, Shinichi

    2014-01-01

    While 6 by 20 of type culture fungi could grow on an interface between organic solvent (log P, 4.12) and agar plate, 13 by 20 of strains could form a large colony after the removal of more toxic solvent, such as styrene (log P, 2.95) and tert-butyl acetate (log P, 1.76) because of viability of spores on the interface.

  1. [Analysis of bactericidal material generated by electrical devices advertising bactericidal ability against bacteria on the agar gel plates].

    PubMed

    Nishimura, Hidekazu

    2012-11-01

    Several Japanese companies sell electrical devices advertised as effective in inactivating viruses and killing bacteria by releasing special materials, e.g., Plasmacluster ions, Nanoe particle and minus ions, into the air. These companies claim that their devices killed bacteria on plates in their own experiments. We tested device effectiveness using the same experiments from the Plasmacluster ioniser SHARP Co., Japan, the Nanoe generator Panasonic Co., Japan, and the Vion KING JIM Co., Japan, to test their advertising claims. Bactericidal ability on agar plate was tested, using Staphylococcus aureus, Pseudomonas aeruginosa, Bacillus cereus, and Enterococcus faecalis as follows: the medium containing a certain amount of each bacterium was put onto an agar plate and smeared. Plates were kept in a closed chamber (inner volume 14.4 m3) or a glove box (inner volume 0.2 m), with one of the devices run for 2 hours. Plates not exposed to any device were used as controls. Each plate was retrieved and put in an incubator to count the number of bacterial colonies formed on the plate. There was no significant difference in the number of colonies on plates exposed to devices compared to control, in the number for all devices, or in all bacteria tested in experiments in the 14.4 m3 chamber. These results strongly suggest that these devices have almost no bactericidal effect, at least in space exceeding this volume. Colony formation was suppressed in the glove box in all devices and in all bacteria tested except P. aeruginosa, although the degree of suppression differed among experiments. The colony formation suppression mechanism was analyzed, and indicated that:colony formation did not change even after the removal of Plasmacluster ions, Nanoe particles, or negative ions from the air, while colony formation was decreased drastically by the removal of ozone from space, which was revealed to be generated inevitably during device operation. These results strongly suggest that the

  2. Inaccuracy of the disk diffusion method compared with the agar dilution method for susceptibility testing of Campylobacter spp.

    PubMed

    Lehtopolku, Mirva; Kotilainen, Pirkko; Puukka, Pauli; Nakari, Ulla-Maija; Siitonen, Anja; Eerola, Erkki; Huovinen, Pentti; Hakanen, Antti J

    2012-01-01

    The agar dilution method has been standardized by the CLSI for the susceptibility testing of Campylobacter species, and according to these standards, the disk diffusion method should be used only in screening for macrolide and ciprofloxacin resistance. Nevertheless, the disk diffusion test is currently widely used, since it is easy to perform in clinical microbiology laboratories. In this study, the disk diffusion method was compared to the agar dilution method by analyzing the in vitro activities of seven antimicrobial agents against 174 Campylobacter strains collected in Finland between 2003 and 2008. Recommendations of the CLSI were followed using Mueller-Hinton agar plates with 5% of sheep blood. For each strain, the disk diffusion tests were performed two to four times. Of the 33 erythromycin-resistant strains (MIC, ≥16 μg/ml), 24 (73%) constantly showed a 6-mm erythromycin inhibition zone (i.e., no inhibition), while for seven strains the inhibition zone varied from 6 to 44 mm in repeated measurements. Among the 141 erythromycin-susceptible strains (MIC, <16 μg/ml), erythromycin inhibition zones varied between 6 and 61 mm. Of the 87 ciprofloxacin-resistant strains, 47 (54%) showed 6-mm inhibition zones, while 40 strains showed inhibition zones between 6 and 60 mm. Significant differences between the repetitions were observed in the disk diffusion for all antimicrobial agents and all strains except for the macrolide-resistant strains regarding the macrolides. For 17 (10%) strains, the variation in repeated measurements was substantial. These results show that the disk diffusion method may not be a reliable tool for the susceptibility testing of Campylobacter spp. Further studies are needed to assess whether the disk diffusion test could be improved or whether all susceptibilities of campylobacters should be tested using an MIC-based method.

  3. Rapid identification of Candida albicans by using Albicans ID and fluoroplate agar plates.

    PubMed Central

    Rousselle, P; Freydiere, A M; Couillerot, P J; de Montclos, H; Gille, Y

    1994-01-01

    Two commercially available agar media, Albicans ID and Fluoroplate, that use a chromogenic or a fluorogenic substrate for the detection and identification of Candida albicans were evaluated. From 1,006 clinical samples containing 723 yeast strains, 352 C. albicans strains were detected with either of the two media. The sensitivity of each of the two media was 93.8% and the specificity was 98.6%, with five false-positive reactions for Candida tropicalis and no false-negative reactions. PMID:7883894

  4. Evaluation of heterotrophic plate and chromogenic agar colony counting in water quality laboratories

    PubMed Central

    Hallas, Gary; Monis, Paul

    2015-01-01

    The enumeration of bacteria using plate-based counts is a core technique used by food and water microbiology testing laboratories. However, manual counting of bacterial colonies is both time and labour intensive, can vary between operators and also requires manual entry of results into laboratory information management systems, which can be a source of data entry error. An alternative is to use automated digital colony counters, but there is a lack of peer-reviewed validation data to allow incorporation into standards. We compared the performance of digital counting technology (ProtoCOL3) against manual counting using criteria defined in internationally recognized standard methods. Digital colony counting provided a robust, standardized system suitable for adoption in a commercial testing environment. The digital technology has several advantages:•Improved measurement of uncertainty by using a standard and consistent counting methodology with less operator error.•Efficiency for labour and time (reduced cost).•Elimination of manual entry of data onto LIMS.•Faster result reporting to customers. PMID:26649275

  5. Evaluation of heterotrophic plate and chromogenic agar colony counting in water quality laboratories.

    PubMed

    Hallas, Gary; Monis, Paul

    2015-01-01

    The enumeration of bacteria using plate-based counts is a core technique used by food and water microbiology testing laboratories. However, manual counting of bacterial colonies is both time and labour intensive, can vary between operators and also requires manual entry of results into laboratory information management systems, which can be a source of data entry error. An alternative is to use automated digital colony counters, but there is a lack of peer-reviewed validation data to allow incorporation into standards. We compared the performance of digital counting technology (ProtoCOL3) against manual counting using criteria defined in internationally recognized standard methods. Digital colony counting provided a robust, standardized system suitable for adoption in a commercial testing environment. The digital technology has several advantages:•Improved measurement of uncertainty by using a standard and consistent counting methodology with less operator error.•Efficiency for labour and time (reduced cost).•Elimination of manual entry of data onto LIMS.•Faster result reporting to customers.

  6. Correlation between Agar Plate Screening and Solid-State Fermentation for the Prediction of Cellulase Production by Trichoderma Strains

    PubMed Central

    Florencio, Camila; Couri, Sonia; Farinas, Cristiane Sanchez

    2012-01-01

    The viability of converting biomass into biofuels and chemicals still requires further development towards the reduction of the enzyme production costs. Thus, there is a growing demand for the development of efficient procedures for selection of cellulase-producing microorganisms. This work correlates qualitative screening using agar plate assays with quantitative measurements of cellulase production during cultivation under solid-state fermentation (SSF). The initial screening step consisted of observation of the growth of 78 preselected strains of the genus Trichoderma on plates, using microcrystalline cellulose as carbon source. The 49 strains that were able to grow on this substrate were then subjected to a second screening step using the Congo red test. From this test it was possible to select 10 strains that presented the highest enzymatic indices (EI), with values ranging from 1.51 to 1.90. SSF cultivations using sugarcane bagasse and wheat bran as substrates were performed using selected strains. The CG 104NH strain presented the highest EGase activity (25.93 UI·g−1). The EI results obtained in the screening procedure using plates were compared with cellulase production under SSF. A correlation coefficient (R2) of 0.977 was obtained between the Congo red test and SSF, demonstrating that the two methodologies were in good agreement. PMID:23227312

  7. Preparation and characterization of bio-nanocomposite films of agar and silver nanoparticles: laser ablation method.

    PubMed

    Rhim, Jong-Whan; Wang, Long-Feng; Lee, Yonghoon; Hong, Seok-In

    2014-03-15

    Silver nanoparticles (AgNPs) were prepared by a laser ablation method and composite films with the AgNPs and agar were prepared by solvent casting method. UV-vis absorbance test and transmission electron microscopy (TEM) analysis results revealed that non-agglomerated spherical AgNPs were formed by the laser ablation method. The surface color of the resulting agar/AgNPs films exhibited the characteristic plasmonic effect of the AgNPs with the maximum absorption peaks of 400-407 nm. X-ray diffraction (XRD) test results also exhibited characteristic AgNPs crystals with diffraction peaks observed at 2θ values of 38.39°, 44.49°, and 64.45°, which were corresponding to (111), (200), and (220) crystallographic planes of face-centered cubic (fcc) silver crystals, respectively. Thermogravimetric analysis (TGA) results showed that thermal stability of the agar/AgNPs composite films was increased by the inclusion of metallic silver. Water vapor barrier properties and surface hydrophobicity of the agar/AgNPs films increased slightly with the increase in AgNPs content but they were not statistically significant (p>0.05), while mechanical strength and stiffness of the composite films decreased slightly (p<0.05). The agar/AgNPs films exhibited distinctive antimicrobial activity against both Gram-positive (Listeria monocytogenes) and Gram-negative (Escherichia coli O157:H7) bacterial pathogens.

  8. Evaluation of an immunochromatographic assay for direct identification of thermostable direct hemolysin-producing Vibrio parahaemolyticus colonies on selective agar plates.

    PubMed

    Kawatsu, Kentaro; Sakata, Junko; Yonekita, Taro; Kumeda, Yuko

    2015-12-01

    We evaluated the utility of an immunochromatographic assay (NH IC TDH) in identifying thermostable direct hemolysin (TDH)-producing Vibrio parahaemolyticus colonies on selective agar plates. The sensitivity of the NH IC TDH assay was 100% (189 samples) and its specificity was 100% (41 samples) compared with the presence of tdh.

  9. Evaluating survival of Escherichia coli O157:H7 in frozen and thawed apple cider: potential use of a hydrophobic grid membrane filter-SD-39 agar method.

    PubMed

    Sage, J R; Ingham, S C

    1998-04-01

    To determine the susceptibility of Escherichia coli O157:H7 to freezing and thawing in apple cider, methods that recover injured cells are needed for accurate enumeration. This study compared the ISO-GRID hydrophobic grid membrane filter (HGMF) SD-39 agar method to two other methods: a reference most probable number (MPN) method, and plating on sorbitol MacConkey agar (SMA). To determine numbers of injured cells, SMA spread plating was also compared to Trypticase soy agar (TSA) spread plating. Two strains of E. coli O157:H7 QA 326 and ATCC 43895, were inoculated into presterilized apple cider (10 ml) which was then frozen (-20 degrees C for 24 h). Samples were thawed at 4 degrees C for 4 h, or at 23 degrees C for 1.5 h, or in a microwave oven (700 W for 10 s). Substantial cell death (0.69- to 6.33 log10 CFU/ml decreases) and injury (0.70- to 2.38-log10 CFU/ml decreases) occurred during freezing and thawing. The extent of death and injury varied with strain and thawing method. The TSA spread plating method recovered the most cells while the HGMF method always recovered more viable cells than the reference MPN method and also either recovered significantly more (P < 0.05) cells or a not significantly different number of cells than SMA spread plating. Some injured cells of both strains were not counted by the HGMF method. Significant numbers of cells injured by freezing and thawing at 4 degrees C in apple cider were enumerated in the cider was diluted 1:2 Trypticase soy broth immediately before plating. Two epifluorescent microscopic methods showed that injury was not associated with loss of cell membrane integrity.

  10. Differentiating non-0157:H7 STEC serogroups from ground beef plated on agar media by hyperspetral imaging

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Introduction: The development of an assay to detect and confirm a positive non-O157:H7 isolate is challenging when mixed morphologically results are obtained from the serogroups growing on Rainbow agar. Rainbow agar is only claimed by the manufacturer to be very specific for E.coli O157:H7 strain...

  11. Modification of the Congo red agar method to detect biofilm production by Staphylococcus epidermidis.

    PubMed

    Kaiser, Thaís Dias Lemos; Pereira, Eliezer Menezes; Dos Santos, Kátia Regina Netto; Maciel, Ethel Leonor Noia; Schuenck, Ricardo Pinto; Nunes, Ana Paula Ferreira

    2013-03-01

    Staphylococcus epidermidis in immunocompromised patients can cause bacteremia related to the use of catheter due to biofilm production. There are different phenotypic methods to detect biofilm formation. One method is based on culture in brain heart infusion agar (BHIA) containing sucrose and red Congo dye (original Congo red agar). Our group created a new CRA formula and we have confirmed its capacity to detect biofilm production in 210 S. epidermidis strains, including 76 (36.2%) icaAB gene-positive strains. Other parameters were also evaluated. The new CRA formula that gave the best results was BHIA with sucrose (5%), Congo red (0.08%), NaCl (1.5%), glucose (2%), and vancomycin (0.5 mg/mL) (vancomycin-modified CRA-CRAmod). The CRAmod plus vancomycin may be a promising tool and can help to determine the real participation of S. epidermidis in the infectious process.

  12. Tentative inhibition zone criteria (Bauer-Kirby agar disk diffusion method) for rifampin against staphylococci.

    PubMed

    Traub, W H; Spohr, M; Bauer, D

    1987-01-01

    Two of 359 (0.6%) clinical isolates of Staphylococcus aureus and 12 of 218 (5.5%) clinical isolates of coagulase-negative staphylococci were resistant or of intermediate susceptibility against rifampin as based on minimal inhibitory concentration (MIC) breakpoints obtained with the agar dilution method: MIC greater than or equal to 2 micrograms/ml = resistant; MIC 0.25-1 microgram/ml = intermediate susceptible; MIC less than 0.125 microgram/ml = susceptible. The following inhibition zone criteria with 2 micrograms rifampin disks were proposed for staphylococcal isolates utilizing the Bauer-Kirby agar disk diffusion test: diameter of inhibition zones less than or equal to 13 mm = resistant; diameter 14-21 mm = intermediate susceptible; diameter greater than or equal to 22 mm = susceptible.

  13. A comparison of serial plate agar dilution, Bauer-Kirby disk diffusion, and the Vitek AutoMicrobic system for the determination of susceptibilities of Klebsiella spp., Enterobacter spp., and Pseudomonas aeruginosa to ten antimicrobial agents.

    PubMed

    Fekete, T; Tumah, H; Woodwell, J; Truant, A; Satishchandran, V; Axelrod, P; Kreter, B

    1994-04-01

    The use of rapid, automated technologies for assessment of antimicrobial susceptibility and determination of minimum inhibitory concentrations has been evolving for over a decade. We compared the Vitek AutoMicrobic system and Bauer-Kirby disk diffusion with the National Committee for Clinical Laboratory Standards methods of serial plate agar dilution for qualitative and quantitative susceptibilities of 301 hospital isolates of Klebsiella spp., Enterobacter spp., and Pseudomonas aeruginosa. Antibiotics tested were aztreonam, cefoperazone, ceftazidime, ceftriaxone, ciprofloxacin, gentamicin, imipenem, piperacillin, ticarcillin-clavulanic acid, and tobramycin. Agar dilution and Bauer-Kirby results were more strongly correlated for all three genera than were the results for agar dilution and Vitek. If agar dilution is presumed to be the "gold standard," Bauer-Kirby disk diffusion had only half the number of false susceptibles as did the Vitek. Thus, the Vitek AutoMicrobic system seems to be somewhat less reliable for both qualitative and quantitative measurement of susceptibility and resistance than is Bauer-Kirby disk diffusion.

  14. Optimisation of a direct plating method for the detection and enumeration of Alicyclobacillus acidoterrestris spores.

    PubMed

    Henczka, Marek; Djas, Małgorzata; Filipek, Katarzyna

    2013-01-01

    A direct plating method for the detection and enumeration of Alicyclobacillus acidoterrestris spores has been optimised. The results of the application of four types of growth media (BAT agar, YSG agar, K agar and SK agar) regarding the recovery and enumeration of A. acidoterrestris spores were compared. The influence of the type of applied growth medium, heat shock conditions, incubation temperature, incubation time, plating technique and the presence of apple juice in the sample on the accuracy of the detection and enumeration of A. acidoterrestris spores was investigated. Among the investigated media, YSG agar was the most sensitive medium, and its application resulted in the highest recovery of A. acidoterrestris spores, while K agar and BAT agar were the least suitable media. The effect of the heat shock time on the recovery of spores was negligible. When there was a low concentration of spores in a sample, the membrane filtration method was superior to the spread plating method. The obtained results show that heat shock carried out at 80°C for 10 min and plating samples in combination with membrane filtration on YSG agar, followed by incubation at 46°C for 3 days provided the optimal conditions for the detection and enumeration of A. acidoterrestris spores. Application of the presented method allows highly efficient, fast and sensitive identification and enumeration of A. acidoterrestris spores in food products. This methodology will be useful for the fruit juice industry for identifying products contaminated with A. acidoterrestris spores, and its practical application may prevent economic losses for manufacturers.

  15. Identification of Brucella by MALDI-TOF Mass Spectrometry. Fast and Reliable Identification from Agar Plates and Blood Cultures

    PubMed Central

    Ferreira, Laura; Vega Castaño, Silvia; Sánchez-Juanes, Fernando; González-Cabrero, Sandra; Menegotto, Fabiola; Orduña-Domingo, Antonio

    2010-01-01

    Background MALDI-TOF mass spectrometry (MS) is a reliable method for bacteria identification. Some databases used for this purpose lack reference profiles for Brucella species, which is still an important pathogen in wide areas around the world. We report the creation of profiles for MALDI-TOF Biotyper 2.0 database (Bruker Daltonics, Germany) and their usefulness for identifying brucellae from culture plates and blood cultures. Methodology/Principal Findings We created MALDI Biotyper 2.0 profiles for type strains belonging to B. melitensis biotypes 1, 2 and 3; B. abortus biotypes 1, 2, 5 and 9; B. suis, B. canis, B ceti and B. pinnipedialis. Then, 131 clinical isolates grown on plate cultures were used in triplicate to check identification. Identification at genus level was always correct, although in most cases the three replicates reported different identification at species level. Simulated blood cultures were performed with type strains belonging to the main human pathogenic species (B. melitensis, B. abortus, B. suis and B. canis), and studied by MALDI-TOF MS in triplicate. Identification at genus level was always correct. Conclusions/Significance MALDI-TOF MS is reliable for Brucella identification to the genus level from culture plates and directly from blood culture bottles. PMID:21151913

  16. COMPARISON OF MENTEROCOCCUS AGAR AND THE U.S. ENVIRONMENTAL PROTECTION AGENCY-RECOMENDED ENTEROCOCCI METHODS, ME AND MEI AGAR

    EPA Science Inventory

    To maintain waters that are "fishable and swimmable", mandated by the Clean Water Act, the U.S. Environmental Protection Agency (EPA) is developing a list of approved methods for use in enumerating enterococci and E. coli in ambient waters. As part of this effort, we compared mEn...

  17. Reliability of the agar based method to assess the production of degradative enzymes in clinical isolates of Candida albicans.

    PubMed

    Arantes, Paula Tamião; Sanitá, Paula Volpato; Santezi, Carolina; Barbeiro, Camila de Oliveira; Reina, Bárbara Donadon; Vergani, Carlos Eduardo; Dovigo, Lívia Nordi

    2016-03-01

    The aim of this study was to establish a reproducible protocol using the methodology of hyaline zones around the colonies on specific agar plates for phospholipase and proteinase production. This was an in vitro double-blind experiment, in which the dependent variables were the enzymatic activity measurements (Pz) for the production of phospholipase (Pz-ph) and the production of secreted aspartyl proteinases (Pz-sap). Three independent variables give rise to different measurement protocols. All measurements were carried out at two different moments by four examiners (E1, E2, E3, and E4). The minimum sample size was 30 Candida albicans clinical isolates. Specific agar plates for phospholipase and SAPs production were prepared according the literature. The intra-and inter-examiner reproducibility for each protocol was estimated using the Intraclass Correlation Coefficient (ICC) and its confidence interval (95% CI). Based on the results obtained for both phospholipase and SAPs, there appears to be no consensus on the protocol chosen for each particular examiner. Measuring the colonies in triplicate may be the main factor associated with the increase in measurement accuracy and should therefore take precedence over measuring only one colony. When only one examiner is responsible for taking measurements, a standard protocol should be put in place and the statistical calibration of this researcher should be done prior to data collection. However, if two or more researchers are involved in the assessment of agar plates, our results suggest that the protocols using software to undertake plate reading is preferred.

  18. Evaluation of agar dilution and broth microdilution methods to determine the disinfectant susceptibility.

    PubMed

    Wu, Guoyan; Yang, Qianru; Long, Mei; Guo, Lijuan; Li, Bei; Meng, Yue; Zhang, Anyun; Wang, Hongning; Liu, Shuliang; Zou, Likou

    2015-11-01

    A variety of disinfectants have been widely used in veterinary hygiene, food industries and environments, which could induce the development of bacterial resistance to disinfectants. The methods used to investigate antimicrobial effects of disinfectant vary considerably among studies, making comparisons difficult. In this study, agar dilution and broth microdilution methods were used to compare the antimicrobial activities of four quaternary ammonium compounds (QACs) against foodborne and zoonotic pathogens. The potential relationship between the presence of QACs resistance genes and phenotypic resistance to QACs was also investigated. Our results indicated that the minimum inhibitory concentrations (MICs) determined by two methods might be different depended upon different QACs and bacteria applied. Regardless of the testing methods, Klebsiella pneumoniae was more tolerant among Gram-negative strains to four QACs, followed by Salmonella and Escherichia coli. The agreement between MICs obtained by the two methods was good, for benzalkonium chloride (78.15%), didecyldimethylammonium chloride (DDAC) (82.35%), cetylpyridinium chloride (CTPC) (97.48%) and cetyltrimethylammonium bromide (CTAB) (99.16%), respectively. Among all Gram-negative bacteria, 94.55% (n=52) of qacEΔ1-positive strains showed higher MICs (512 mg l(-1)) to CTAB. The qacEΔ1 gene was highly associated (P<0.05) with the high MICs of QACs (⩾512 mg l(-1)). In addition, DDAC remained as the most effective disinfectant against both Gram-positive and Gram-negative bacteria. This is the first study that compared the agar dilution and broth microdilution methods to assess the antimicrobial activity of QACs. The study demonstrated the need to standardize method that would be used in evaluating QACs antimicrobial properties in the future.

  19. Multilaboratory Comparison of Proficiencies in Susceptibility Testing of Helicobacter pylori and Correlation between Agar Dilution and E Test Methods

    PubMed Central

    Best, L. M.; Haldane, D. J. M.; Keelan, M.; Taylor, D. E.; Thomson, A. B. R.; Loo, V.; Fallone, C. A.; Lyn, P.; Smaill, F. M.; Hunt, R.; Gaudreau, C.; Kennedy, J.; Alfa, M.; Pelletier, R.; Veldhuyzen van Zanten, S. J. O.

    2003-01-01

    Susceptibility testing was performed at seven Canadian microbiology laboratories and the Helicobacter Reference Laboratory, Halifax, Nova Scotia, Canada, to assess susceptibility testing proficiency and the reproducibility of the results for clarithromycin and metronidazole and to compare the Epsilometer test (E test) method to the agar dilution reference method. Control strain Helicobacter pylori ATCC 43504 (American Type Culture Collection) and 13 clinical isolates (plus duplicates of four of these strains including ATCC 43504) were tested blindly. The National Committee for Clinical Laboratory Standards (NCCLS) guidelines for agar dilution testing were followed, and the same suspension of organisms was used for agar dilution and E test. Antimicrobials and E test strips were provided to the investigators. Methods were provided on a website (www.Helicobactercanada.org). Each center reported MICs within the stated range for strain ATCC 43504. Compared to the average MICs, interlaboratory agreements within 2 log2 dilutions were 90% (range, 69 to 100%) for clarithromycin by agar dilution, with seven very major errors [VMEs], and 85% (range, 65 to 100%) by E test, with three VMEs. Interlaboratory agreements within 2 log2 dilutions were 83% (range, 50 to 100%) for metronidazole by agar dilution, with six VMEs and eight major errors (MEs), and 75% (range, 50 to 94%) by E test, with four VMEs and four MEs. At lower and higher concentrations of antibiotic, E test MICs were slightly different from agar dilution MICs, but these differences did not result in errors. When a standardized protocol based on NCCLS guidelines was used, most participants in this study correctly identified clarithromycin- and metronidazole-susceptible and -resistant strains of H. pylori 93% of the time by either the agar dilution or E test method, and the numbers of errors were relatively equivalent by both methods. PMID:14506021

  20. Multilaboratory comparison of proficiencies in susceptibility testing of Helicobacter pylori and correlation between agar dilution and E test methods.

    PubMed

    Best, L M; Haldane, D J M; Keelan, M; Taylor, D E; Thomson, A B R; Loo, V; Fallone, C A; Lyn, P; Smaill, F M; Hunt, R; Gaudreau, C; Kennedy, J; Alfa, M; Pelletier, R; Veldhuyzen Van Zanten, S J O

    2003-10-01

    Susceptibility testing was performed at seven Canadian microbiology laboratories and the Helicobacter Reference Laboratory, Halifax, Nova Scotia, Canada, to assess susceptibility testing proficiency and the reproducibility of the results for clarithromycin and metronidazole and to compare the Epsilometer test (E test) method to the agar dilution reference method. Control strain Helicobacter pylori ATCC 43504 (American Type Culture Collection) and 13 clinical isolates (plus duplicates of four of these strains including ATCC 43504) were tested blindly. The National Committee for Clinical Laboratory Standards (NCCLS) guidelines for agar dilution testing were followed, and the same suspension of organisms was used for agar dilution and E test. Antimicrobials and E test strips were provided to the investigators. Methods were provided on a website (www.Helicobactercanada.org). Each center reported MICs within the stated range for strain ATCC 43504. Compared to the average MICs, interlaboratory agreements within 2 log(2) dilutions were 90% (range, 69 to 100%) for clarithromycin by agar dilution, with seven very major errors [VMEs], and 85% (range, 65 to 100%) by E test, with three VMEs. Interlaboratory agreements within 2 log(2) dilutions were 83% (range, 50 to 100%) for metronidazole by agar dilution, with six VMEs and eight major errors (MEs), and 75% (range, 50 to 94%) by E test, with four VMEs and four MEs. At lower and higher concentrations of antibiotic, E test MICs were slightly different from agar dilution MICs, but these differences did not result in errors. When a standardized protocol based on NCCLS guidelines was used, most participants in this study correctly identified clarithromycin- and metronidazole-susceptible and -resistant strains of H. pylori 93% of the time by either the agar dilution or E test method, and the numbers of errors were relatively equivalent by both methods.

  1. A comparison study of the EF-18 agar/Hydrophobic Grid Membrane Filter (HGMF) method and the enzyme linked antibody (ELA)/HGMF method to the HPB standard method in the isolation of Salmonella.

    PubMed

    Warburton, D W; Arling, V; Worobec, S; Mackenzie, J; Todd, E C; Lacasse, P; Lamontagne, G; Plante, R; Shaw, S; Bowen, B

    1994-09-01

    As part of a comparative and collaborative study of rapid methods for the detection of Salmonella and the standard Health Protection Branch (HPB) method, six Federal and Provincial Laboratories compared the EF-18 agar/Hydrophobic Grid Membrane Filters (HGMF) method to the standard HPB method. Two Federal Laboratories also compared the enzyme linked antibody (ELA)/HGMF method (which is a further development of the EF-18 agar/HGMF method) to the standard method. During this study the false-negative rates ranged from 0% to 15% for the standard HPB method, from 5.88% to 43.5% for the EF-18 agar/HGMF method, and from 0% to 10.5% for the ELA/HGMF method. The EF-18 agar/HGMF method did not compare well with the standard HPB method due to the number of false-negatives. Problems with this method resulted from the inability to isolate colonies of Salmonella on the HGMF due to the small colony size, abnormal colony coloration, and overgrowth by competitors. The ELA/HGMF method, however, was shown to be comparable to the standard HPB method. The main advantages of this method are that the antibody-staining step is independent of colony coloration and carbohydrate utilization on the plating media; the ability to detect some unusual strains of Salmonella irrespective of their atypical reactions on the media; and the ELA staining can indicate the presence of Salmonella even when the HGMF is overgrown by competitors. Also, cultural confirmation can proceed simultaneously yet independently of the ELA staining procedure. The data presented here indicate that this method is worth further study.

  2. Antimicrobial susceptibility of Erysipelothrix rhusiopathiae isolated from pigs in Southern Japan with a modified agar dilution method.

    PubMed

    Chuma, Takehisa; Kawamoto, Toshio; Shahada, Francis; Fujimoto, Hideki; Okamoto, Karoku

    2010-05-01

    The determination of antimicrobial minimum inhibitory concentration (MIC) in Erysipelothrix rhusiopathiae by using the agar dilution method has not been covered by the Clinical and Laboratory Institute (CLSI). Only the broth microdilution method has been outlined. This report describes a modification of the agar dilution procedure for E. rhusiopathiae using Trypto-soy agar supplemented with 0.1% Tween 80 and incubation in ambient air at 37 degrees C for 24 hr. The MICs of the assay were in agreement with those of the broth microdilution method recommended by the CLSI. Antimicrobial susceptibility test was performed using this method for 149 E. rhusiopathiae isolates from 2 meat processing plants in Kagoshima Prefecture during the period of April 2004 to March 2005. The number of strains resistant to oxytetracycline, erythromycin, lincomycin, ofloxacin and enrofloxacin were 56 (37.6%), 4 (2.7%), 18 (12.1%), 21 (14.1%) and 19 (12.8%), respectively. All strains were susceptible to ampicillin.

  3. Criteria for the interpretation of the pipemidic acid agar diffusion test by the Kirby-Bauer method.

    PubMed

    Grimm, H

    1983-01-01

    The antibiotic sensitivity of 296 strains of Pseudomonas aeruginosa and 294 isolates of other species was measured by the agar diffusion test with 20 micrograms pipemidic acid (Deblaston) discs on Mueller-Hinton agar by the Kirby-Bauer method. The correlation between inhibition zone diameter and minimal inhibitory concentration was worked out by regression analysis. In all bacterial species investigated, an inhibition zone of 14 mm or more indicates sensitivity to pipemidic acid. For Pseudomonas aeruginosa an intermediate zone of 11 to 13 mm is recommended.

  4. Comparison of the antibacterial activity of chelating agents using the agar diffusion method

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The agar diffusion assay was used to examine antibacterial activity of 2 metal chelators. Concentrations of 0 to 40 mM of ethylenediaminetetraacetic acid (EDTA) and ethylenediamine-N,N’-disuccinic acid (EDDS) were prepared in 1.0 M potassium hydroxide (KOH). The pH of the solutions was adjusted to 1...

  5. In vitro antifungal susceptibility testing of Scopulariopsis brevicaulis strains using agar diffusion method.

    PubMed

    Skóra, Magdalena; Macura, Anna B

    2011-01-01

    The genus Scopulariopsis is a common soil saprotroph and has been isolated from air, organic waste and also from plant, animal and human tissues. Scopulariopsis has mainly been associated in humans with superficial mycoses, but it has also been described as the cause of subcutaneous and invasive infections. The most common aetiological agent of infections in humans is Scopulariopsis brevicaulis. This species has been reported to be resistant in vitro to broad-spectrum antifungal agents available today. The aim of the study was to establish in vitro antifungal susceptibility of 35 S. brevicaulis strains against amphotericin B (AMB), flucytosine (FC), caspofungin (CAS), terbinafine (TER), ciclopirox (CIC), voriconazole (VOR), clotrimazole (CTR), miconazole (MCZ), econazole (ECO), ketoconazole (KET), itraconazole (ITR), and fluconazole (FLU). Antifungal susceptibility tests were evaluated by an agar diffusion method (Neo-Sensitabs, Rosco, Denmark). AMB, FC, CAS, ITR and FLU showed no antifungal activity against S. brevicaulis. TER, CIC, CTR, KET, VOR, ECO, and MCZ revealed inhibitory activity for S. brevicaulis, but it varied for each of the drugs. The best antifungal effect was observed for TER and CIC. All isolates had large inhibition zones for TER and CIC. CTR was also inhibitory for all tested S. brevicaulis isolates, but the diameters of inhibition zones were smaller than for TER and CIC. Nearly 89% isolates showed inhibition zones for KET and the mean diameter of the inhibition zone was comparable to CTR. The least antifungal activity exhibited VQR, ECO and MCZ. Because of the multiresistance of S. brevicaulis, infections due to this species may not respond to particular antifungal treatment and other therapeutic approaches should be considered, e.g., combined therapy and/or surgery.

  6. Metronidazole susceptibility testing for Helicobacter pylori: comparison of disk, broth, and agar dilution methods and their clinical relevance.

    PubMed Central

    DeCross, A J; Marshall, B J; McCallum, R W; Hoffman, S R; Barrett, L J; Guerrant, R L

    1993-01-01

    Since the methods for metronidazole susceptibility testing of Helicobacter pylori have not been standardized or validated, we compared three methods that are used to test the metronidazole susceptibilities of 25 isolates of H. pylori. Specifically, we examined the methods of Steer's replicator agar dilution, tube broth microdilution, and modified Kirby-Bauer disk diffusion. The metronidazole disk zone sizes obtained by the disk diffusion method correlated well (r = 0.74) with the MICs obtained by the agar dilution method. Afterward, the disk diffusion method was used to characterize the metronidazole susceptibilities of 44 isolates of H. pylori. Dual therapy (bismuth and metronidazole) proved to be highly effective against metronidazole-susceptible strains (81.6% eradication rate) but fared poorly against resistant strains (16.7% eradication rate; P < 0.01). Using agar dilution testing, we validated the modified Kirby-Bauer disk diffusion method for metronidazole susceptibility testing of H. pylori and conclude that it is practical, accurate, and clinically applicable. PMID:8370723

  7. Method for plating with metal oxides

    SciTech Connect

    Silver, Gary L.; Martin, Frank S.

    1994-08-23

    A method of plating hydrous metal oxides on at least one substrate, which method is indifferent to the electrochemical properties of the substrate, and comprises reacting metallic ions in aqueous solution with an appropriate oxidizing agent such as sodium hypochlorite or calcium sulfite with oxygen under suitable conditions of pH and concentration such that oxidation and precipitation of metal oxide are sufficiently slow to allow satisfactory plating of metal oxide on the substrate.

  8. Method for plating with metal oxides

    SciTech Connect

    Silver, G.L.; Martin, F.S.

    1994-08-23

    A method is disclosed of plating hydrous metal oxides on at least one substrate, which method is indifferent to the electrochemical properties of the substrate, and comprises reacting metallic ions in aqueous solution with an appropriate oxidizing agent such as sodium hypochlorite or calcium sulfite with oxygen under suitable conditions of pH and concentration such that oxidation and precipitation of metal oxide are sufficiently slow to allow satisfactory plating of metal oxide on the substrate. 1 fig.

  9. Effusion plate using additive manufacturing methods

    DOEpatents

    Johnson, Thomas Edward; Keener, Christopher Paul; Ostebee, Heath Michael; Wegerif, Daniel Gerritt

    2016-04-12

    Additive manufacturing techniques may be utilized to construct effusion plates. Such additive manufacturing techniques may include defining a configuration for an effusion plate having one or more internal cooling channels. The manufacturing techniques may further include depositing a powder into a chamber, applying an energy source to the deposited powder, and consolidating the powder into a cross-sectional shape corresponding to the defined configuration. Such methods may be implemented to construct an effusion plate having one or more channels with a curved cross-sectional geometry.

  10. VIDAS Salmonella (SLM) assay method EasySLM with ChromID Salmonella (SM2) Agar. Performance Tested Method 020901.

    PubMed

    Johnson, Ronald; Mills, John; Colón-Reveles, Judith

    2009-01-01

    A method modification study was conducted for the VIDAS Salmonella (SLM) assay (AOAC Performance Tested Method 020901) using the EasySLM method to validate a matrix extension for peanut butter. The VIDAS EasySLM method is a simple enrichment procedure compared to traditional Salmonella methods, requiring only pre-enrichment and a single selective enrichment media, Salmonella Xpress 2 (SX2) broth. SX2 replaces the two selective broths in traditional methods and eliminates the M broth transfer, incubation, and subsequent pooling of M broths prior to VIDAS assay. The validation study was conducted under the AOAC Research Institute Emergency Response Validation program. VIDAS SLM was compared to the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA-BAM) method for detection of S. enterica ser. Typhimurium in peanut butter. All peanut butter samples were prepared, blind-coded, and shipped to the method developers' laboratory by Q Laboratories. In addition, Q Laboratories performed most probable number and reference method analyses on peanut butter samples. The VIDAS EasySLM ChromID Salmonella (SM2) Agar was previously validated in the Performance Tested Methods program for the detection of Salmonella in roast beef, raw ground pork, turkey, pork sausage, raw chicken breast, dry pet food, whole milk, ice cream, bagged spinach, shrimp (raw, peeled), raw cod, spent irrigation water, pecans, peanut butter, dry pasta, cake mix, ground black pepper, nonfat dry milk, liquid eggs, cantaloupe, and orange juice. In the matrix extension study for peanut butter, the VIDAS EasySLM method was shown to be equivalent to the appropriate reference culture procedure using both buffered peptone water pre-enrichment and the FDA-BAM lactose pre-enrichment in the two-step enrichment method with SX2 media. The current study extends the validation to include peanut butter.

  11. Use of urease-bromothymol blue-agar method for large-scale testing of urine on grain and seeds.

    PubMed

    Valdes, P A; Ziobro, G C; Ferrera, R S

    1996-01-01

    The current AOAC method (963.28) for large-scale (50 g) testing of urine on grain is based on the reaction of sodium in urine with magnesium uranyl acetate. Detection of sodium suggests that urine is present and that a test for urea is appropriate. Urea is detected with urease-bromothymol blue-paper and is confirmed through its reaction with xanthydrol to form dixanthylurea crystals, which are detected microscopically. The initial nonspecific test for sodium can be influenced by the presence of salt or other sodium compounds. Furthermore, the magnesium uranyl acetate spray used in Method 963.28 potentially exposes the analyst to the aerosol of a volatile, toxic uranium compound. Excess reagents and analyzed test portions must be disposed of as radioactive waste. In addition, Method 963.28 requires several steps to determine the presence of urea. The alternative AOAC method (972.41) tests for the presence of urea from urine on individual seeds. Urea is enzymatically decomposed to ammonia and carbon dioxide by urease. Liberated ammonia shifts the pH, changing the color of the indicator in the agar from yellow to blue. This study adapts Method 972.41 to larger test samples. Up to 25 g grains and seeds are sprayed with urease test agar instead of being individually immersed in the urease test agar. The modified method was used to analyze urea on seeds and grains of 24 plants from 4 families. The method has a limit of detection of one seed contaminated with 1 microgram urea.

  12. Electro-osmosis in gels: Application to Agar-Agar

    NASA Astrophysics Data System (ADS)

    Cherblanc, Fabien; Boscus, Jérôme; Bénet, Jean-Claude

    2008-10-01

    Widely used in food- and bio-engineering as a reference material, Agar-Agar gel is the focus of an experimental investigation concerning the electro-osmosis phenomenon. After presenting the experimental methods, one trial is discussed in detail. A fair reproducibility of results is obtained, and the averaged electro-osmotic permeability is provided. This value lies in the range generally measured on various kind of soils, even if Agar-Agar gel does not share any micro-structural characteristics with soils. To cite this article: F. Cherblanc et al., C. R. Mecanique 336 (2008).

  13. Residual Agar Determination in Bacterial Spores by Electrospray Ionization Mass Spectrometry

    SciTech Connect

    Wahl, Karen L.; Colburn, Heather A.; Wunschel, David S.; Petersen, Catherine E.; Jarman, Kristin H.; Valentine, Nancy B.

    2010-02-15

    Presented here is an analytical method to detect residual agar from a bacterial spore sample as an indication of culturing on an agar plate. This method is based on the resolubilization of agar polysaccharide from a bacterial spore sample, enzymatic digestion, followed by electrospray ionization tandem mass spectrometry (ESI-MSn) analysis for detection of a specific agar fragment ion. A range of Bacillus species and strains were selected to demonstrate the effectiveness of this approach. The characteristic agar fragment ion was detected in the spores grown on agar that were washed from 1 to 5 times, irradiated or non-irradiated and not in the spores grown in broth. A sample containing approximately 108 spores is currently needed for confident detection of residual agar from culture on agar plates in the presence of bacterial spores with a limit of detection of approximately 1 ppm agar spiked into a broth-grown spore sample. The results of a proficiency test with 42 blinded samples are presented demonstrating the utility of this method with no false positives and only 3 false negatives for samples that were below the detection level of the method as documented.

  14. Antimicrobial Activity of Endodontic Medicaments and Vehicles using Agar Well Diffusion Method on Facultative and Obligate Anaerobes

    PubMed Central

    Bhat, Kishore G; Sogi, Suma

    2016-01-01

    Aims The aim of this study was to determine the relative antimicrobial effectiveness of these endodontic medicaments and various vehicles using an agar well diffusion assay. Materials and methods Double Antibiotic Paste(DAP), modified DAP, 2% Chlorhexidine gluconate and their combination with four vehicles namely Polyethylene glycol 400 (PEG), Propylene glycol (PG), combinations of PG with PEG and lastly Glycerine were tested using agar well diffusion assay. The minimum bactericidal concentration was noted against four standard strains of organisms ie Streptococcus mutans ATCC( American Type Culture Collection) 25175, Staphylococcus aureus ATCC 12598, Enterococcus faecalis ATCC 35550 and Eschericia coli ATCC 25922. Successful endodontic therapy depends upon thorough disinfection of root canals. In some refractory cases, routine endodontic therapy is not sufficient, so intracanal medicaments are used for proper disinfection of canals. Issues of resistance, limited spectrum of activity and lack of antifungal properties, the hunt for the ideal intracanal medicament continues. In this regard, the vehicles used to form the pastes play a supportive role by forming the appropriate consistency for placement and may dramatically influence their chemical characteristics like their solubility and diffusion. Thus, inorder to use safer and equally effective intracanal medicaments, Chlorhexidine gluconate is being unveiled in this study. Results The difference between the four vehicles when combined with the same endodontic medicament studied above is nonsignificant (NS) except against Porphyromonas gingivalis. Propylene glycol is significantly effective than Glycerine when used with DAP ie C+M medicament combination. (p = 0.029) Conclusion 2% chlorhexidine gluconate and modified DAP can definitely replace DAP and triple antibiotic paste as end-odontic medicaments with chlorhexidine having an added advantage of bactericidal action, substantivity, biocompatibility, low toxicity

  15. A Hidden Pitfall in the Preparation of Agar Media Undermines Microorganism Cultivability

    PubMed Central

    Tanaka, Tomohiro; Kawasaki, Kosei; Daimon, Serina; Kitagawa, Wataru; Yamamoto, Kyosuke; Tamaki, Hideyuki; Tanaka, Michiko; Nakatsu, Cindy H.

    2014-01-01

    Microbiologists have been using agar growth medium for over 120 years. It revolutionized microbiology in the 1890s when microbiologists were seeking effective methods to isolate microorganisms, which led to the successful cultivation of microorganisms as single clones. But there has been a disparity between total cell counts and cultivable cell counts on plates, often referred to as the “great plate count anomaly,” that has long been a phenomenon that still remains unsolved. Here, we report that a common practice microbiologists have employed to prepare agar medium has a hidden pitfall: when phosphate was autoclaved together with agar to prepare solid growth media (PT medium), total colony counts were remarkably lower than those grown on agar plates in which phosphate and agar were separately autoclaved and mixed right before solidification (PS medium). We used a pure culture of Gemmatimonas aurantiaca T-27T and three representative sources of environmental samples, soil, sediment, and water, as inocula and compared colony counts between PT and PS agar plates. There were higher numbers of CFU on PS medium than on PT medium using G. aurantiaca or any of the environmental samples. Chemical analysis of PT agar plates suggested that hydrogen peroxide was contributing to growth inhibition. Comparison of 454 pyrosequences of the environmental samples to the isolates revealed that taxa grown on PS medium were more reflective of the original community structure than those grown on PT medium. Moreover, more hitherto-uncultivated microbes grew on PS than on PT medium. PMID:25281372

  16. A comparison of standard cultural methods for the detection of foodborne Salmonella species including three new chromogenic plating media.

    PubMed

    Schönenbrücher, Vanessa; Mallinson, Edward T; Bülte, Michael

    2008-03-31

    In this study the draft of the horizontal method for the detection of Salmonella species from human food and animal feed (ISO 6579:2002) was compared to the European gold standard (DIN EN 12824:1998), including the three new chromogenic plating media AES Salmonella Agar Plate (ASAP), Oxoid Salmonella Chromogen Media (OSCM) and Miller-Mallinson agar (MM). First the growth and appearance of 36 bacterial type strains (Salmonella and other 21 species) on ASAP, OSCM and MM were compared to those on the three traditional agars Brilliant Green Agar according to Edel and Kampelmacher (BGA), Xylose Lysine Deoxycholate Agar (XLD) and Xylose Lysine Tergitol 4 Agar (XLT4). Only on MM agar, did all of 36 tested type strains produce typical colonies, especially strains of S. Senftenberg, Salmonella arizonae, S. Dublin and S. Derby. Artificial inoculation experiments using raw pork ground meat (n=92) were subsequently conducted. A shortened incubation time of 24 h in RVS broth yielded a Salmonella species recovery of 100% from spiked meat samples. Finally, 286 naturally contaminated raw porcine and bovine minced meat samples and raw poultry meat samples were investigated. Forty-three strains from a total of 39 Salmonella-positive samples were found. S. Typhimurium (n=21), with DT 104 L, DT 012 and RDNC being the most prevalent subtypes isolated. D-tartrate-positive S. Paratyphi B (n=2) and S. Saint-Paul (n=3) were also recovered. They were cultured from poultry meat and were multi-resistant against antibiotics including nalidixic acid. Rappaport Vassiliadis broth with soypeptone (RVS) yielded the highest recovery of Salmonella spp. (97,4%) compared to Tetrathionate broth with Novobiocin according to Muller and Kauffman (MKTTn, 94,9%) and Selenite Cystine broth (SC, 38,5%). However, no significant difference was obtained by comparing the ISO 6579:2002 draft to the gold standard.

  17. The agar diffusion scratch assay - A novel method to assess the bioactive and cytotoxic potential of new materials and compounds

    PubMed Central

    Pusnik, Mascha; Imeri, Minire; Deppierraz, Grégoire; Bruinink, Arie; Zinn, Manfred

    2016-01-01

    A profound in vitro evaluation not only of the cytotoxic but also of bioactive potential of a given compound or material is crucial for predicting potential effects in the in vivo situation. However, most of the current methods have weaknesses in either the quantitative or qualitative assessment of cytotoxicity and/or bioactivity of the test compound. Here we describe a novel assay combining the ISO 10993-5 agar diffusion test and the scratch also termed wound healing assay. In contrast to these original tests this assay is able to detect and distinguish between cytotoxic, cell migration modifying and cytotoxic plus cell migration modifying compounds, and this at higher sensitivity and in a quantitative way. PMID:26861591

  18. Evaluation of the thin agar layer method for the recovery of pressure-injured and heat-injured Listeria monocytogenes.

    PubMed

    Lavieri, Nicolas A; Sebranek, Joseph G; Cordray, Joseph C; Dickson, James S; Jung, Stephanie; Manu, David K; Mendonça, Aubrey F; Brehm-Stecher, Byron F; Stock, Joseph; Stalder, Kenneth J

    2014-05-01

    A sublethally injured bacterial cell has been defined as a cell that survives a stress such as heating, freezing, acid treatment, or other antimicrobial intervention but can repair the cellular damage exerted by the stressor and later regain its original ability to grow. Consequently, sublethally injured cells are not likely to be included in conventional enumeration procedures, which could result in unrealistically low counts unless efforts are made to encourage recovery of the injured cells before enumeration. The objective of this study was to evaluate the use of the thin agar layer (TAL) method for the recovery of pressure-injured and heat-injured Listeria monocytogenes in a tryptic soy broth with 0.6% yeast extract system. Pressure injury consisted of treatment of a culture of mixed L. monocytogenes strains with high hydrostatic pressure at 400 or 600 MPa for 1 s, 2 min, 4 min, or 6 min at a process temperature of 12±2 °C. Heat injury consisted of treatment of a culture of mixed L. monocytogenes strains at 60±1 °C for 3, 6, or 9 min. Growth media were tryptic soy agar (TSA) with 0.6% yeast extract, modified Oxford medium (MOX), and TAL, which consisted of a 7-ml layer of TSA overlaid onto solidified MOX. Counts of viable L. monocytogenes on TAL were higher than those on MOX in the heat-injury experiment but not in the pressure-injury experiment. Therefore, the effectiveness of the TAL method may be specific to the type of injury applied to the microorganism and should be investigated in a variety of cellular injury scenarios.

  19. A novel agar formulation for isolation and direct enumeration of Vibrio vulnificus from oyster tissue.

    PubMed

    Griffitt, Kimberly J; Grimes, D Jay

    2013-08-01

    A new selective and differential medium, Vibrio vulnificus X-Gal (VVX), was developed for direct enumeration of V. vulnificus (Vv) from oyster samples. This agar utilizes cellobiose and lactose as carbon sources, and the antibiotics colistin and polymyxin B as selective agents. Hydrolysis of 5-bromo-4-chloro-3-indolyl- beta-d-galactopyranoside (x-gal), used in the agar as a lactose analog, produces an insoluble blue dye that makes lactose positive colonies easily distinguishable from any non-lactose fermenting bacteria. Various bacterial species were spot plated onto thiosulfate-citrate-bile salts-sucrose agar (TCBS), and CHROMagar Vibrio, two vibrio-specific selective agars, non-selective agar, and VVX to compare selectivity of VVX to other widely used media. A V. vulnificus pure culture was serially diluted on VVX and non-selective agar to determine the VVX percent recovery. Water and oyster samples were spread plated on VVX agar and allowed to incubate for 16-18 h at 33 °C. Blue and white colonies from VVX agar were picked and screened by end point PCR for the Vv hemolysin vvhA. VVX agar showed a significant improvement over TCBS and CHROMagar at preventing non-target growth. There was an 87.5% recovery compared to non-selective plating and a 98% positivity rate of blue colonies picked from oyster tissue plating. The findings suggest that this new agar is a fast, distinctive, and accurate method for enumeration of V. vulnificus from the environment.

  20. Microporous microchannel plates and method of manufacturing same

    DOEpatents

    Beetz, Jr., Charles P.; Boerstler, Robert W.; Steinbeck, John; Winn, David R.

    2000-01-01

    A microchannel plate and method of manufacturing same is provided. The microchannel plate includes a plate consisting of an anodized material and a plurality of channels which are formed during the anodization of the material and extend between the two sides of the plate. Electrodes are also disposed on each side of the plate for generating an electrical field within the channels. Preferably, the material is alumina and the channels are activated such that the channel walls are conductive and highly secondary emissive.

  1. [Detection of TDH-producing Vibrio parahaemolyticus O3:K6 from naturally contaminated shellfish using an immunomagnetic separation method and chromogenic agar medium].

    PubMed

    Hara-Kudo, Y; Sugiyama, K; Nishina, T; Saitoh, A; Nakagawa, H; Ichihara, T; Konuma, H; Hasegawa, J; Kumagai, S

    2001-11-01

    We attempted to isolate TDH-producing Vibrio parahaemolyticus O3:K6 from shellfish. Asari samples were incubated with TSB supplemented with 2% (w/v) NaCl for 6 h, and then the 6-h cultures were incubated with salt polymyxin broth for 18 h. After the two-step enrichment, a 1 ml portion of the culture was treated with magnetic beads coated with K6 antibody for immunoconcentration of V. parahaemolyticus O3:K6. The immunoconcentrated and untreated cultures were plated onto a chromogenic agar and TCBS agar media for isolation of V. parahaemolyticus. TDH-producing V. parahaemolyticus O3:K6 was isolated from 3 out of 66 lots (4.5%) of naturally contaminated Asari. Six of 4,265 colonies suspected as V. parahaemolyticus (0.14%) were TDH-producing V. parahaemolyticus O3:K6.

  2. Reproducibility of control organism zone diameters for batches of IsoSensitest agar manufactured from 1996 to 2000 using the BSAC disc susceptibility test method.

    PubMed

    Landrygan, Janine; James, Peter A; Brooks, Dawn; Kubiak, Elizabeth M

    2002-02-01

    The BSAC Working Party on Susceptibility Testing has recently suggested that the performance of IsoSensitest agar has changed since 1991. Twenty batches of IsoSensitest agar that had been manufactured between 1996 and 2000 were tested using the BSAC standardized disc susceptibility testing method. Antibiotic discs containing amoxicillin 10 microg, ceftazidime 30 microg, gentamicin 10 microg, ciprofloxacin 1 microg and colistin sulphate 25 microg were tested on each batch of media 12 times against Escherichia coli ATCC 25922, Staphylococcus aureus ATCC 25923 and Pseudomonas aeruginosa ATCC 27853 where appropriate. There was a small reduction in zone sizes for most antibiotics on batches of media that were near their expiration date, but otherwise zone sizes were remarkably consistent. We could find no evidence to suggest that a change in the performance of IsoSensitest agar for the disc diffusion method had occurred since 1996.

  3. Performance of the EUCAST disk diffusion method, the CLSI agar screen method, and the Vitek 2 automated antimicrobial susceptibility testing system for detection of clinical isolates of Enterococci with low- and medium-level VanB-type vancomycin resistance: a multicenter study.

    PubMed

    Hegstad, Kristin; Giske, Christian G; Haldorsen, Bjørg; Matuschek, Erika; Schønning, Kristian; Leegaard, Truls M; Kahlmeter, Gunnar; Sundsfjord, Arnfinn

    2014-05-01

    Different antimicrobial susceptibility testing methods to detect low-level vancomycin resistance in enterococci were evaluated in a Scandinavian multicenter study (n=28). A phenotypically and genotypically well-characterized diverse collection of Enterococcus faecalis (n=12) and Enterococcus faecium (n=18) strains with and without nonsusceptibility to vancomycin was examined blindly in Danish (n=5), Norwegian (n=13), and Swedish (n=10) laboratories using the EUCAST disk diffusion method (n=28) and the CLSI agar screen (n=18) or the Vitek 2 system (bioMérieux) (n=5). The EUCAST disk diffusion method (very major error [VME] rate, 7.0%; sensitivity, 0.93; major error [ME] rate, 2.4%; specificity, 0.98) and CLSI agar screen (VME rate, 6.6%; sensitivity, 0.93; ME rate, 5.6%; specificity, 0.94) performed significantly better (P=0.02) than the Vitek 2 system (VME rate, 13%; sensitivity, 0.87; ME rate, 0%; specificity, 1). The performance of the EUCAST disk diffusion method was challenged by differences in vancomycin inhibition zone sizes as well as the experience of the personnel in interpreting fuzzy zone edges as an indication of vancomycin resistance. Laboratories using Oxoid agar (P<0.0001) or Merck Mueller-Hinton (MH) agar (P=0.027) for the disk diffusion assay performed significantly better than did laboratories using BBL MH II medium. Laboratories using Difco brain heart infusion (BHI) agar for the CLSI agar screen performed significantly better (P=0.017) than did those using Oxoid BHI agar. In conclusion, both the EUCAST disk diffusion and CLSI agar screening methods performed acceptably (sensitivity, 0.93; specificity, 0.94 to 0.98) in the detection of VanB-type vancomycin-resistant enterococci with low-level resistance. Importantly, use of the CLSI agar screen requires careful monitoring of the vancomycin concentration in the plates. Moreover, disk diffusion methodology requires that personnel be trained in interpreting zone edges.

  4. Numerical results for extended field method applications. [thin plates

    NASA Technical Reports Server (NTRS)

    Donaldson, B. K.; Chander, S.

    1973-01-01

    This paper presents the numerical results obtained when a new method of analysis, called the extended field method, was applied to several thin plate problems including one with non-rectangular geometry, and one problem involving both beams and a plate. The numerical results show that the quality of the single plate solutions was satisfactory for all cases except those involving a freely deflecting plate corner. The results for the beam and plate structure were satisfactory even though the structure had a freely deflecting corner.

  5. [An observation on the histological structure of Oncomelania hupensis soft tissue by agar-paraffin double-embedding method].

    PubMed

    Tan, Ping; Zhang, Jie; Li, Qing; Yu, Zhi-jun

    2014-12-01

    In order to study the histological structure of Oncomelania hupensis soft tissue, the fixed soft tissues of O. hupensis were pre-embedded in the agar and made blocks, then dehydrated, transparentized, immersed in paraffin, sectioned, and stained with haematoxylin-eosin (HE). Permanent slides of O. hupensis soft tissue were obtained. The histological structure of soft tissues was clear under the microscope.

  6. Ice-Cap: a method for growing Arabidopsis and tomato plants in 96-well plates for high-throughput genotyping.

    PubMed

    Su, Shih-Heng; Clark, Katie A; Gibbs, Nicole M; Bush, Susan M; Krysan, Patrick J

    2011-11-09

    It is becoming common for plant scientists to develop projects that require the genotyping of large numbers of plants. The first step in any genotyping project is to collect a tissue sample from each individual plant. The traditional approach to this task is to sample plants one-at-a-time. If one wishes to genotype hundreds or thousands of individuals, however, using this strategy results in a significant bottleneck in the genotyping pipeline. The Ice-Cap method that we describe here provides a high-throughput solution to this challenge by allowing one scientist to collect tissue from several thousand seedlings in a single day (1,2). This level of throughput is made possible by the fact that tissue is harvested from plants 96-at-a-time, rather than one-at-a-time. The Ice-Cap method provides an integrated platform for performing seedling growth, tissue harvest, and DNA extraction. The basis for Ice-Cap is the growth of seedlings in a stacked pair of 96-well plates. The wells of the upper plate contain plugs of agar growth media on which individual seedlings germinate. The roots grow down through the agar media, exit the upper plate through a hole, and pass into a lower plate containing water. To harvest tissue for DNA extraction, the water in the lower plate containing root tissue is rapidly frozen while the seedlings in the upper plate remain at room temperature. The upper plate is then peeled away from the lower plate, yielding one plate with 96 root tissue samples frozen in ice and one plate with 96 viable seedlings. The technique is named "Ice-Cap" because it uses ice to capture the root tissue. The 96-well plate containing the seedlings can then wrapped in foil and transferred to low temperature. This process suspends further growth of the seedlings, but does not affect their viability. Once genotype analysis has been completed, seedlings with the desired genotype can be transferred from the 96-well plate to soil for further propagation. We have demonstrated

  7. Solution of non-rectangular plates with macroelement method

    NASA Astrophysics Data System (ADS)

    Delyavskyy, Mykhaylo; Rosinski, Krystian

    2017-03-01

    New approach to static analysis of thin non-rectangular arbitrarily loaded plates, called the macroelement method, has been developed in this paper. Macroelement is a rectangular plate which entirely contains real plate. The mathematical model of macroelement was built. The equilibrium equations are performed for macroelement and boundary conditions are written on the line corresponding to contour of real plate in the nodes which are zero points of trigonometric functions, included in the macroelement model. The load is applied only to separate nodes on the surface of real plate, whereas the complement of a plate to macroelement is unloaded. Analysis of construction is reduced to solving a system of linear algebraic equations. The method provides better accuracy compared to finite element method and requires less equations. There is trapeze plate clamped at inclined edge and simply supported at opposite one considered in this paper. The other edges of the plate are free. Uniformly distributed load on the surface of real plate is taken into account.

  8. Vibration Analysis of Plates by MLS-Element Method

    NASA Astrophysics Data System (ADS)

    Zhou, L.; Xiang, Y.

    2010-05-01

    This paper presents a novel numerical method, the moving least square element (MLS-element) method for the free vibration analysis of plates based on the Mindlin shear deformable plate theory. In the MLS-element method, a plate can be first divided into multiple elements which are connected through selected nodal points on the interfaces of the elements. An element can be of any shape and the size of the element varies dependent on the problem at hand. The shape functions of the element for the transverse displacement and the rotations are derived based on the MLS interpolation technique. The convergence and accuracy of the method can be controlled by either increasing the number of elements or by increasing the number of MLS interpolation points within elements. Two selected examples for vibration of a simply supported square Mindlin plate and a clamped L-shaped Mindlin plate are studied to illustrate the versatility and accuracy of the proposed method. It shows that the proposed method is highly accurate and flexible for the vibration analysis of plate problems. The method can be further developed to bridge the existing meshless method and the powerful finite element method in dealing with various engineering computational problems, such as large deformation and crack propagation in solid mechanics.

  9. Conductivity fuel cell collector plate and method of fabrication

    DOEpatents

    Braun, James C.

    2002-01-01

    An improved method of manufacturing a PEM fuel cell collector plate is disclosed. During molding a highly conductive polymer composite is formed having a relatively high polymer concentration along its external surfaces. After molding the polymer rich layer is removed from the land areas by machining, grinding or similar process. This layer removal results in increased overall conductivity of the molded collector plate. The polymer rich surface remains in the collector plate channels, providing increased mechanical strength and other benefits to the channels. The improved method also permits greater mold cavity thickness providing a number of advantages during the molding process.

  10. Light scattering sensor for real-time identification of Vibrio parahaemolyticus, V. vulnificus and V. cholera colonies on solid agar plates

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The three most common pathogenic species of Vibrio, V. cholerae, V. parahemolyticus and V. vulnificus, are of major concern as water- and food-borne pathogens because of an increasing incidence of water and seafood related outbreaks and illnesses worldwide. Current methods are time-consuming and req...

  11. Xanthan gum: an economical partial substitute for agar in microbial culture media.

    PubMed

    Babbar, Shashi B; Jain, Ruchi

    2006-04-01

    Xanthan gum, microbial desiccation-resistant polysaccharide prepared commercially by aerobic submerged fermentation from Xanthomonas campestris, has been successfully used alone and in combination with agar for microbial culture media. As illustrative examples, eight bacteria and eight fungi were grown on media solidified with either agar (A, 1.5%), xanthan gum (X, 1%), or combinations of both (0.9% X + 0.1% A, 0.8% X + 0.2% A, 0.7% X + 0.3% A, 0.6% X + 0.4% A). All fungi and bacteria exhibited normal growth and differentiation in all these treatments. Rather, growth of most of the fungi was better on xanthan (alone) and xanthan + agar media than agar medium. As the media gelled with xanthan gum alone flow, it was not possible to incubate Petri plates in inverted position. Moreover, because of the softness, streaking of bacteria was difficult on such media. However, these problems could be overcome by partially replacing xanthan gum with 0.3% agar. Bacterial enumeration studies carried out for Serratia sp. and Pseudomonas sp. by serial dilution and pour-plate method on agar (1.5%), 0.7%/0.6% X + 0.3%/0.4% A yielded similar counts. Selective media, succinate medium for Pseudomonas sp., and MacConkey broth medium for Escherichia coli gelled with 0.7%/0.6% X + 0.3%/0.4% A did not support growth of other bacteria when inoculated along with the above-mentioned bacteria. Likewise, differential medium, CRMA (Congo red mannitol agar) gelled with xanthan-agar combination could differentiate between Agrobacterium tumefaciens and Rhizobium sp.

  12. Bacteria holding times for fecal coliform by mFC agar method and total coliform and Escherichia coli by Colilert®-18 Quanti-Tray® method

    USGS Publications Warehouse

    Aulenbach, Brent T.

    2010-01-01

    Bacteria holding-time experiments of up to 62 h were performed on five surface-water samples from four urban stream sites in the vicinity of Atlanta, GA, USA that had relatively high densities of coliform bacteria (Escherichia coli densities were all well above the US Environmental Protection Agency criterion of 126 colonies (100 ml) − 1 for recreational waters). Holding-time experiments were done for fecal coliform using the membrane filtration modified fecal coliform (mFC) agar method and for total coliform and E. coli using the Colilert®-18 Quanti-Tray® method. The precisions of these analytical methods were quantified. Precisions determined for fecal coliform indicated that the upper bound of the ideal range of counts could reasonably be extended upward and would improve precision. For the Colilert®-18 method, analytical precisions were similar to the theoretical precisions for this method. Fecal and total coliform densities did not change significantly with holding times up to about 27 h. Limited information indicated that fecal coliform densities might be stable for holding times of up to 62 h, whereas total coliform densities might not be stable for holding times greater than about 27 h. E. coli densities were stable for holding times of up to 18 h—a shorter period than indicated from a previous studies. These results should be applicable to non-regulatory monitoring sampling designs for similar urban surface-water sample types.

  13. Methicillin-Resistant Staphylococcus aureus (MRSA) Detection: Comparison of Two Molecular Methods (IDI-MRSA PCR Assay and GenoType MRSA Direct PCR Assay) with Three Selective MRSA Agars (MRSA ID, MRSASelect, and CHROMagar MRSA) for Use with Infection-Control Swabs▿

    PubMed Central

    van Hal, S. J.; Stark, D.; Lockwood, B.; Marriott, D.; Harkness, J.

    2007-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is an increasing problem. Rapid detection of MRSA-colonized patients has the potential to limit spread of the organism. We evaluated the sensitivities and specificities of MRSA detection by two molecular methods (IDI-MRSA PCR assay and GenoType MRSA Direct PCR assay) and three selective MRSA agars (MRSA ID, MRSASelect, and CHROMagar MRSA), using 205 (101 nasal, 52 groin, and 52 axillary samples) samples from consecutive known MRSA-infected and/or -colonized patients. All detection methods had higher MRSA detection rates for nasal swabs than for axillary and groin swabs. Detection of MRSA by IDI-MRSA was the most sensitive method, independent of the site (94% for nasal samples, 80% for nonnasal samples, and 90% overall). The sensitivities of the GenoType MRSA Direct assay and the MRSA ID, MRSASelect, and CHROMagar MRSA agars with nasal swabs were 70%, 72%, 68%, and 75%, respectively. All detection methods had high specificities (95 to 99%), independent of the swab site. Extended incubation for a further 24 h with selective MRSA agars increased the detection of MRSA, with a corresponding decline in specificity secondary to a significant increase in false-positive results. There was a noticeable difference in test performance of the GenoType MRSA Direct assay in detection of MRSA (28/38 samples [74%]) compared with detection of nonmultiresistant MRSA (17/31 samples [55%]) (susceptible to two or more non-β-lactam antibiotics). This was not observed with selective MRSA agar plates or IDI-MRSA. Although it is more expensive, in addition to rapid turnaround times of 2 to 4 h, IDI-MRSA offers greater detection of MRSA colonization, independent of the swab site, than do conventional selective agars and GenoType MRSA Direct. PMID:17537949

  14. Comparison of the recoveries of Escherichia coli and total coliforms from drinking water by the MI agar method and the U.S. Environmental Protection Agency-approved membrane filter method.

    PubMed Central

    Brenner, K P; Rankin, C C; Sivaganesan, M; Scarpino, P V

    1996-01-01

    Drinking water regulations under the Final Coliform Rule require that total coliform-positive drinking water samples be examined for the presence of Escherichia coli or fecal coliforms. The current U.S. Environmental Protection Agency-approved membrane filter (MF) method for E. coli requires two media, an MF transfer, and a total incubation time of 28 h. A newly developed MF method, the MI agar method, containing indoxyl-beta-D-glucuronide and 4-methylumbelliferyl-beta-D-galactopyranoside for the simultaneous detection of E. coli and total coliforms, respectively, by means of their specific enzyme reactions, was compared with the approved method by the use of wastewater-spiked tap water samples. Overall, weighted analysis of variance (significance level, 0.05) showed that the new medium recoveries of total coliforms and E. coli were significantly higher than those of mEndo agar and nutrient agar plus MUG (4-methylumbelliferyl-beta-D-glucuronide), respectively, and the background counts were significantly lower than those of mEndo agar (< 5%). Generally, the tap water source, overall chlorine level, wastewater source, granular activated carbon treatment of the tap water, and method of grouping data by E. coli count for statistical analysis did not affect the performance of the new medium. PMID:8572697

  15. Method to reduce damage to backing plate

    DOEpatents

    Perry, Michael D.; Banks, Paul S.; Stuart, Brent C.

    2001-01-01

    The present invention is a method for penetrating a workpiece using an ultra-short pulse laser beam without causing damage to subsequent surfaces facing the laser. Several embodiments are shown which place holes in fuel injectors without damaging the back surface of the sack in which the fuel is ejected. In one embodiment, pulses from an ultra short pulse laser remove about 10 nm to 1000 nm of material per pulse. In one embodiment, a plasma source is attached to the fuel injector and initiated by common methods such as microwave energy. In another embodiment of the invention, the sack void is filled with a solid. In one other embodiment, a high viscosity liquid is placed within the sack. In general, high-viscosity liquids preferably used in this invention should have a high damage threshold and have a diffusing property.

  16. In vitro susceptibility of Burkholderia cepacia complex isolates: Comparison of disk diffusion, Etest®, agar dilution, and broth microdilution methods.

    PubMed

    Fehlberg, Lorena Cristina Corrêa; Nicoletti, Adriana Gianinni; Ramos, Ana Carolina; Rodrigues-Costa, Fernanda; de Matos, Adriana Pereira; Girardello, Raquel; Marques, Elizabeth Andrade; Gales, Ana Cristina

    2016-12-01

    Broth microdilution, agar dilution, Etest® and disk diffusion techniques were compared to evaluate the susceptibility profile of 82 Bcc clinical isolates against six antimicrobials as recommended by CLSI. Broth microdilution was considered the "gold standard" method. The regression analysis was applied to determine the essential (EA) and categorical (CA) agreement rates. STX (MIC50, 1 mg/L) was the most potent antimicrobial tested against Bcc isolates. The worst in vitro activity was observed for chloramphenicol (MIC50, 16 mg/L) and ticarcillin-clavulanic acid (MIC50, >256 mg/L). The EA among broth microdilution and agar dilution results was good for the majority of antimicrobial tested. When comparing broth microdilution and Etest®, ceftazidime, SXT and chloramphenicol exhibited EA rates below 90%. SXT showed an excellent CA (100%) when dilution methodologies were compared. However, a low CA rate was found for this agent between dilution and disk diffusion methodologies resulting in unacceptable very major and minor error rates.

  17. Standardized methods and quality control limits for agar and broth microdilution susceptibility testing of Mycoplasma pneumoniae, Mycoplasma hominis, and Ureaplasma urealyticum.

    PubMed

    Waites, Ken B; Duffy, Lynn B; Bébéar, Cécile M; Matlow, Anne; Talkington, Deborah F; Kenny, George E; Totten, Patricia A; Bade, Donald J; Zheng, Xiaotian; Davidson, Maureen K; Shortridge, Virginia D; Watts, Jeffrey L; Brown, Steven D

    2012-11-01

    An international multilaboratory collaborative study was conducted to develop standard media and consensus methods for the performance and quality control of antimicrobial susceptibility testing of Mycoplasma pneumoniae, Mycoplasma hominis, and Ureaplasma urealyticum using broth microdilution and agar dilution techniques. A reference strain from the American Type Culture Collection was designated for each species, which was to be used for quality control purposes. Repeat testing of replicate samples of each reference strain by participating laboratories utilizing both methods and different lots of media enabled a 3- to 4-dilution MIC range to be established for drugs in several different classes, including tetracyclines, macrolides, ketolides, lincosamides, and fluoroquinolones. This represents the first multilaboratory collaboration to standardize susceptibility testing methods and to designate quality control parameters to ensure accurate and reliable assay results for mycoplasmas and ureaplasmas that infect humans.

  18. Comparison of direct-plating and enrichment methods for isolation of Vibrio cholerae from diarrhea patients.

    PubMed Central

    Lesmana, M; Richie, E; Subekti, D; Simanjuntak, C; Walz, S E

    1997-01-01

    A direct-plating method on thiosulfate citrate bile salts sucrose agar (DIR-TCBS) in conjunction with enrichment in alkaline peptone water (APW) incubated for both 6 h and 24 h followed by subculture onto TCBS (APW6h-TCBS and APW24h-TCBS, respectively) was performed on 16,034 rectal swab samples for isolating Vibrio cholerae. A total of 2,932 (18.3%) rectal swab samples were positive for V. cholerae O1 biotype El Tor, with the Ogawa serotype constituting 99.2% of the isolates. There were no significant differences in V. cholerae O1 isolation rates between the three culture systems nor between the combinations of any two systems. However, direct plating plus enrichment demonstrated a significantly higher V. cholerae O1 isolation rate than DIR-TCBS alone (P < 0.02). Conversely, enrichment procedure, alone or in combination with DIR-TCBS, yielded significantly more (P < 0.0001) V. cholerae non-O1 isolates than DIR-TCBS alone. The length of incubation time of the enrichment broth, 6 h, offers no significant advantages over 24 h for the isolation of V. cholerae O1 and non-O1. A 24-h enrichment broth incubation period has the practical advantage of being easy to integrate into a normal laboratory workday, whereas 6-h broth enrichment, although more commonly recommended, requires that arrangements be made for after-hours subculture. PMID:9196208

  19. Method for conducting electroless metal-plating processes

    DOEpatents

    Petit, George S.; Wright, Ralph R.

    1978-01-01

    This invention is an improved method for conducting electroless metal-plating processes in a metal tank which is exposed to the plating bath. The invention solves a problem commonly encountered in such processes: how to determine when it is advisable to shutdown the process in order to clean and/or re-passivate the tank. The new method comprises contacting the bath with a current-conducting, non-catalytic probe and, during plating operations, monitoring the gradually changing difference in electropotential between the probe and tank. It has been found that the value of this voltage is indicative of the extent to which nickel-bearing decomposition products accumulate on the tank. By utilizing the voltage to determine when shutdown for cleaning is advisable, the operator can avoid premature shutdown and at the same time avoid prolonging operations to the point that spontaneous decomposition occurs.

  20. Soft-agar-coated filter method for early detection of viable and thermostable direct hemolysin (TDH)- or TDH-related hemolysin-producing Vibrio parahaemolyticus in seafood.

    PubMed

    Hayashi, Sachiko; Okura, Masatoshi; Osawa, Ro

    2006-07-01

    A novel method for detecting viable and thermostable direct hemolysin (TDH)-producing or TDH-related hemolysin (TRH)-producing Vibrio parahaemolyticus in seafood was developed. The method involved (i) enrichment culture, selective for viable, motile cells penetrating a soft-agar-coated filter paper, and (ii) a multiplex PCR assay targeting both the TDH gene (tdh) and TRH gene (trh) following DNase pretreatment on the test culture to eradicate any incidental DNAs that might have been released from dead cells of tdh- or trh-positive (tdh+ trh+) strains and penetrated the agar-coated filter. A set of preliminary laboratory tests performed on 190 ml of enrichment culture that had been inoculated simultaneously with ca. 100 viable cells of a strain of tdh+ trh+ V. parahaemolyticus and dense populations of a viable strain of tdh- and trh-negative V. parahaemolyticus or Vibrio alginolyticus indicated that the method detected the presence of viable tdh+ trh+ strains. Another set of preliminary tests on 190 ml of enrichment culture that had been initially inoculated with a large number of dead cells of the tdh+ trh+ strain together with dense populations of the tdh- and trh-negative strains confirmed that the method did not yield any false-positive results. Subsequent quasi-field tests using various seafood samples (ca. 20 g), each of which was experimentally contaminated with either or both hemolysin-producing strains at an initial density of ca. 5 to 10 viable cells per gram, demonstrated that contamination could be detected within 2 working days.

  1. A 6 x 6 drop plate method for simultaneous colony counting and MPN enumeration of Campylobacter jejuni, Listeria monocytogenes, and Escherichia coli.

    PubMed

    Chen, Chin Yi; Nace, Gary W; Irwin, Peter L

    2003-11-01

    A protocol was developed using 96-well plates and multichannel pipettes for serial dilutions, followed by drop plating on agar in a 6 x 6 format. This protocol permits simultaneous plating of six dilutions which greatly decreases the number of plates utilized thereby saving incubator space for organisms such as Campylobacter which require unique environmental conditions.

  2. Improved soft-agar colony assay in a fluid processing apparatus.

    PubMed

    Forsman, A D; Herpich, A R; Chapes, S K

    1999-01-01

    The standard method for quantitating bone marrow precursor cells has been to count the number of colony-forming units that form in semisolid (0.3%) agar. Recently we adapted this assay for use in hardware, the Fluid Processing Apparatus, that is flown in standard payload lockers of the space shuttle. When mouse or rat macrophage colony-forming units were measured with this hardware in ground-based assays, we found significantly more colony growth than that seen in standard plate assays. The improved growth correlates with increased agar thickness but also appears to be due to properties inherent to the Fluid Processing Apparatus. This paper describes an improved method for determining bone marrow macrophage precursor numbers in semisolid agar.

  3. Improved hydrophobic grid membrane filter method, using EF-18 agar, for detection of Salmonella in foods: collaborative study.

    PubMed

    Entis, P

    1990-01-01

    A collaborative study was carried out in 30 laboratories to validate improvements to the official final action hydrophobic grid membrane filter (HGMF) screening method for Salmonella in foods, 985.42, by comparing the performance of the improved HGMF method against that of the AOAC/BAM conventional culture method. Six products were included in the collaborative study: milk chocolate, raw deboned poultry meat, black pepper, soy flour, egg yolk powder, and nonfat dry milk. The raw deboned poultry meat was naturally contaminated with Salmonella, and the remaining 5 products were each inoculated in advance with low levels of individual Salmonella serotypes. The AOAC/BAM method produced 11 false negative results and the improved HGMF method produced 18 false negative results. The improved HGMF Salmonella method has been approved interim official first action for all foods to replace the HGMF official final action method, 985.42.

  4. Application of optical diffraction method in designing phase plates

    NASA Astrophysics Data System (ADS)

    Lei, Ze-Min; Sun, Xiao-Yan; Lv, Feng-Nian; Zhang, Zhen; Lu, Xing-Qiang

    2016-11-01

    Continuous phase plate (CPP), which has a function of beam shaping in laser systems, is one kind of important diffractive optics. Based on the Fourier transform of the Gerchberg-Saxton (G-S) algorithm for designing CPP, we proposed an optical diffraction method according to the real system conditions. A thin lens can complete the Fourier transform of the input signal and the inverse propagation of light can be implemented in a program. Using both of the two functions can realize the iteration process to calculate the near-field distribution of light and the far-field repeatedly, which is similar to the G-S algorithm. The results show that using the optical diffraction method can design a CPP for a complicated laser system, and make the CPP have abilities of beam shaping and phase compensation for the phase aberration of the system. The method can improve the adaptation of the phase plate in systems with phase aberrations.

  5. Comparative study of agar diffusion test and the NCCLS macrobroth method for in vitro susceptibility testing of Candida spp.

    PubMed

    Soni, L M; Burattini, M N; Pignatari, A C; Gompertz, O F; Colombo, A L

    1999-01-01

    We performed a prospective double-blind study to evaluate the correlation between inhibition zones obtained by a disk-diffusion test, using Neo-sensitabs of fluconazole (Rosco Diagnostica), and the MICs generated by the NCCLS macrobroth dilution assay. Eighty clinical isolates, representing 5 of the clinically relevant species of Candida, were tested simultaneously by both methods. A clear inverse correlation was found between the results obtained by both tests (r = -0.69). In addition, there was high degree of agreement between methods in the identification of susceptible isolates. However, the resistance definition by disk-diffusion test had a positive predictive value of only 17%. Our data support the hypothesis that Rosco Fluconazole Neo-sensitabs have potential as a screening test for the identification of Candida isolates susceptible to fluconazole. Resistant isolates should be further investigated by standardized broth procedures.

  6. Synthesis of bimetallic nanoshells by an improved electroless plating method.

    PubMed

    Liu, J B; Dong, W; Zhan, P; Wang, S Z; Zhang, J H; Wang, Z L

    2005-03-01

    In the Letter, we demonstrate an improved electroless plating method for the synthesis of bimetallic shell particles. The procedure involves a combination of surface reaction, seeding growth, and removal of supporting cores. We modified ammonical AgNO3 in ethanol with a controlled amount of HCHO in the seeding process and a uniform and relatively dense coverage of silver nanoparticle seeds on colloid cores was achieved. Following the second kind of metal plating, we extended this method to prepare continuous bimetallic core-shell and hollow particles with a submicrometer diameter. The morphologies of the bimetallic Cu/Ag and Pt/Ag particles were studied with transmission electron microscopy and scanning electron microscopy, and their crystallinity and chemical composition were confirmed by X-ray diffraction. The prepared materials may be of applied value in areas such as catalysis, optics, and plasmonics.

  7. Performance of CHROMAGAR candida and BIGGY agar for identification of yeast species

    PubMed Central

    Yücesoy, Mine; Marol, Serhat

    2003-01-01

    Background The importance of identifying the pathogenic fungi rapidly has encouraged the development of differential media for the presumptive identification of yeasts. In this study two differential media, CHROMagar Candida and bismuth sulphite glucose glycine yeast agar, were evaluated for the presumptive identification of yeast species. Methods A total number of 270 yeast strains including 169 Candida albicans, 33 C. tropicalis, 24 C. glabrata, 18 C. parapsilosis, 12 C. krusei, 5 Trichosporon spp., 4 C. kefyr, 2 C. lusitaniae, 1 Saccharomyces cerevisiae and 1 Geotrichum candidum were included. The strains were first identified by germ tube test, morphological characteristics on cornmeal tween 80 agar and Vitek 32 and API 20 C AUX systems. In parallel, they were also streaked onto CHROMagar Candida and bismuth sulphite glucose glycine yeast agar plates. The results were read according to the color, morphology of the colonies and the existance of halo around them after 48 hours of incubation at 37°C. Results The sensitivity and specificity values for C. albicans strains were found to be 99.4, 100% for CHROMagar Candida and 87.0, 75.2% for BiGGY agar, respectively. The sensitivity of CHROMagar Candida to identify C. tropicalis, C. glabrata and C. krusei ranged between 90.9 and 100% while the specificity was 100%. The sensitivity rates for BiGGY agar were 66.6 and 100% while the specificity values were found to be 95.4 and 100% for C. tropicalis and C. krusei, respectively. Conclusions It can be concluded that the use of CHROMagar Candida is an easy and reliable method for the presumptive identification of most commonly isolated Candida species especially C. albicans, C. tropicalis and C. krusei. The lower sensitivity and specificity of BiGGY agar to identify commonly isolated Candida species potentially limits the clinical usefulness of this agar. PMID:14613587

  8. Comparison of polymerase chain reaction methods and plating for analysis of enriched cultures of Listeria monocytogenes when using the ISO11290-1 method.

    PubMed

    Dalmasso, Marion; Bolocan, Andrei Sorin; Hernandez, Marta; Kapetanakou, Anastasia E; Kuchta, Tomáš; Manios, Stavros G; Melero, Beatriz; Minarovičová, Jana; Muhterem, Meryem; Nicolau, Anca Ioana; Rovira, Jordi; Skandamis, Panagiotis N; Stessl, Beatrix; Wagner, Martin; Jordan, Kieran; Rodríguez-Lázaro, David

    2014-03-01

    Analysis for Listeria monocytogenes by ISO11290-1 is time-consuming, entailing two enrichment steps and subsequent plating on agar plates, taking five days without isolate confirmation. The aim of this study was to determine if a polymerase chain reaction (PCR) assay could be used for analysis of the first and second enrichment broths, saving four or two days, respectively. In a comprehensive approach involving six European laboratories, PCR and traditional plating of both enrichment broths from the ISO11290-1 method were compared for the detection of L. monocytogenes in 872 food, raw material and processing environment samples from 13 different dairy and meat food chains. After the first and second enrichments, total DNA was extracted from the enriched cultures and analysed for the presence of L. monocytogenes DNA by PCR. DNA extraction by chaotropic solid-phase extraction (spin column-based silica) combined with real-time PCR (RTi-PCR) was required as it was shown that crude DNA extraction applying sonication lysis and boiling followed by traditional gel-based PCR resulted in fewer positive results than plating. The RTi-PCR results were compared to plating, as defined by the ISO11290-1 method. For first and second enrichments, 90% of the samples gave the same results by RTi-PCR and plating, whatever the RTi-PCR method used. For the samples that gave different results, plating was significantly more accurate for detection of positive samples than RTi-PCR from the first enrichment, but RTi-PCR detected a greater number of positive samples than plating from the second enrichment, regardless of the RTi-PCR method used. RTi-PCR was more accurate for non-food contact surface and food contact surface samples than for food and raw material samples especially from the first enrichment, probably because of sample matrix interference. Even though RTi-PCR analysis of the first enrichment showed less positive results than plating, in outbreak scenarios where a rapid result is

  9. Gravimorphogenesis in agarics.

    PubMed

    Moore, D; Hock, B; Greening, J P; Kern, V D; Novak Frazer, L; Monzer, J

    1996-03-01

    The shape changes which occur in agaric fruit bodies in response to change in the direction of gravity, usually referred to as gravitropism are morphogenetic changes. Our interest in what we prefer to call gravimorphogenesis is to use it to examine morphogenesis experimentally. We are examining two agarics, Coprinus cinereus and Flammulina velutipes, and applying the best available technologies, including video analysis, all forms of electron microscopy, computer-aided image analysis and experiments in orbit in Spacelab. Responses to gravity of the two organisms differ in ways which can be related to their ecological and structural adaptations. C. cinereus reacts extremely rapidly; its fruit body can regain the vertical within 3 h of being placed horizontal, whereas F. velutipes requires 12 h to bend through 90 degrees. The fungi also differ in the bulk of tissue involved in the response. In Coprinus, a zone extending several cm down from the apex is normally involved in bending. In Flammulina, gravisensing is limited to a region just a few mm immediately below the cap, although curvature is performed in a zone of up to 2 cm below. Flammulina cultures were flown on the Spacelab D-2 mission in 1993, and fruit body disorientation in orbit provides the first definitive proof that 'gravitropism' really is a response to the unidirectional gravity vector. Experiments with different clinostat rotation rates in Flammulina indicate that the perception threshold is about 10(-4) x g. Analysis of different times of exposure to an altered gravity vector prior to clinorotation in Coprinus reveals that the perception time is 7 minutes and that continued response requires continued exposure. Cell size determinations in Coprinus demonstrate that cells of the stem increase in length, not diameter, to produce the growth differential. In Flammulina a unique population of highly electron-transparent microvacuoles changes in distribution; decreasing in upper cells and increasing in the

  10. 21 CFR 184.1115 - Agar-agar.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Agar-agar. 184.1115 Section 184.1115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) DIRECT FOOD SUBSTANCES AFFIRMED AS GENERALLY RECOGNIZED AS SAFE Listing of...

  11. Plate damage identification using wave propagation and impedance methods.

    SciTech Connect

    Wait, J. R.; Park, G. H.; Sohn, H.; Farrar, C. R.

    2004-01-01

    This paper illustrates an integrated approach for identifying structural damage in an aluminum plate. Piezoelectric (PZT) materials are used to actuatehense the dynamic response of the structure. Two damage identification techniques are integrated in this study, including Lamb wave propagations and impedance methods. In Lamb wave propagations, one PZT launches an elastic wave through the structure, and responses are measured by an array of PZT sensors. The changes in both wave attenuation and reflection are used to detect and locate the damage. The impedance method monitors the variations in structural mechanical impedance, which is coupled with the electrical impedance of the PZT. Both methods operate in high frequency ranges at which there are measurable changes in structural responses even for incipient damage such as small cracks or loose connections. This paper summarizes two methods used for damage identification, experimental procedures, and additional issues that can be used as a guideline for future investigations.

  12. Enumeration of total aerobic microorganisms in foods by SimPlate Total Plate Count-Color Indicator methods and conventional culture methods: collaborative study.

    PubMed

    Feldsine, Philip T; Leung, Stephanie C; Lienau, Andrew H; Mui, Linda A; Townsend, David E

    2003-01-01

    The relative efficacy of the SimPlate Total Plate Count-Color Indicator (TPC-CI) method (SimPlate 35 degrees C) was compared with the AOAC Official Method 966.23 (AOAC 35 degrees C) for enumeration of total aerobic microorganisms in foods. The SimPlate TPC-CI method, incubated at 30 degrees C (SimPlate 30 degrees C), was also compared with the International Organization for Standardization (ISO) 4833 method (ISO 30 degrees C). Six food types were analyzed: ground black pepper, flour, nut meats, frozen hamburger patties, frozen fruits, and fresh vegetables. All foods tested were naturally contaminated. Nineteen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery among the SimPlate methods and their corresponding reference methods. Mean log counts between the 2 reference methods were also very similar. Repeatability (Sr) and reproducibility (SR) standard deviations were similar among the 3 method comparisons. The SimPlate method (35 degrees C) and the AOAC method were comparable for enumerating total aerobic microorganisms in foods. Similarly, the SimPlate method (30 degrees C) was comparable to the ISO method when samples were prepared and incubated according to the ISO method.

  13. Thermal diffusivity of nonflat plates using the flash method

    SciTech Connect

    Salazar, Agustin; Fuente, Raquel; Apinaniz, Estibaliz; Mendioroz, Arantza

    2011-01-15

    The flash method is the standard technique to measure the thermal diffusivity of solid samples. It consists of heating the front surface of an opaque sample by a brief light pulse and detecting the temperature evolution at its rear surface. The thermal diffusivity is obtained by measuring the time corresponding to the half maximum of the temperature rise, which only depends on the sample thickness and thermal diffusivity through a simple formula. Up to now, the flash method has been restricted to flat samples. In this work, we extend the flash method to measure the thermal diffusivity of nonflat samples. In particular, we focus on plates with cylindrical and spherical shapes. The theoretical model indicates that the same expression for flat samples can also be applied to cylindrical and spherical plates, except for extremely curved samples. Accordingly, a curvature limit for the application of the expression for flat samples is established. Flash measurements on lead foils of cylindrical shape confirm the validity of the model.

  14. Thermal diffusivity of nonflat plates using the flash method

    NASA Astrophysics Data System (ADS)

    Salazar, Agustín; Fuente, Raquel; Apiñaniz, Estibaliz; Mendioroz, Arantza

    2011-01-01

    The flash method is the standard technique to measure the thermal diffusivity of solid samples. It consists of heating the front surface of an opaque sample by a brief light pulse and detecting the temperature evolution at its rear surface. The thermal diffusivity is obtained by measuring the time corresponding to the half maximum of the temperature rise, which only depends on the sample thickness and thermal diffusivity through a simple formula. Up to now, the flash method has been restricted to flat samples. In this work, we extend the flash method to measure the thermal diffusivity of nonflat samples. In particular, we focus on plates with cylindrical and spherical shapes. The theoretical model indicates that the same expression for flat samples can also be applied to cylindrical and spherical plates, except for extremely curved samples. Accordingly, a curvature limit for the application of the expression for flat samples is established. Flash measurements on lead foils of cylindrical shape confirm the validity of the model.

  15. Practical method for diffusion welding of steel plate in air.

    NASA Technical Reports Server (NTRS)

    Moore, T. J.; Holko, K. H.

    1972-01-01

    Description of a simple and easily applied method of diffusion welding steel plate in air which does not require a vacuum furnace or hot press. The novel feature of the proposed welding method is that diffusion welds are made in air with deadweight loading. In addition, the use of an autogenous (self-generated) surface-cleaning principle (termed 'auto-vac cleaning') to reduce the effects of surface oxides that normally hinder diffusion welding is examined. A series of nine butt joints were diffusion welded in thick sections of AISI 1020 steel plate. Diffusion welds were attempted at three welding temperatures (1200, 1090, and 980 C) using a deadweight pressure of 34,500 N/sq m (5 psi) and a two-hour hold time at temperature. Auto-vac cleaning operations prior to welding were also studied for the same three temperatures. Results indicate that sound welds were produced at the two higher temperatures when the joints were previously fusion seal welded completely around the periphery. Also, auto-vac cleaning at 1200 C for 2-1/2 hours prior to diffusion welding was highly beneficial, particularly when subsequent welding was accomplished at 1090 C.

  16. An Evaluation Method for the Suppression of Pathogenic Fusarium oxysporum by Soil Microorganisms Using the Dilution Plate Technique

    PubMed Central

    Mitsuboshi, Masahiro; Kioka, Yuuzou; Noguchi, Katsunori; Asakawa, Susumu

    2016-01-01

    Soil-borne diseases caused by pathogenic microorganisms are one of the main factors responsible for the decline in crop yields in farmlands. Pathogenic Fusarium oxysporum causes serious damage to various crops, and, thus, a feasible diagnostic method for soil-borne diseases is required. We herein examined a simple method to evaluate the suppressiveness of soil microorganisms against a pathogen by co-cultivating indigenous soil microorganisms and a pathogenic fungus (F. oxysporum f. sp. spinaciae). We inoculated F. oxysporum onto the center of agar medium plates mixed with a dilution series of a suspension of organic fertilizers or soil. After an approximately one-week cultivation, the growth degree of F. oxysporum was estimated based on the size of the colonies that formed on the plates. The growth degree of F. oxysporum significantly differed among the organic fertilizers tested, indicating the usefulness of the method for evaluating suppressiveness by organic fertilizers. Differences in the growth degrees of F. oxysporum were associated with the incidence of disease in spinach on soil treated with organic fertilizers and inoculated with a pathogenic F. oxysporum strain. These results suggested that this method provides some useful information on the suppressiveness of organic fertilizers and soil against Fusarium wilt. PMID:27558588

  17. An Evaluation Method for the Suppression of Pathogenic Fusarium oxysporum by Soil Microorganisms Using the Dilution Plate Technique.

    PubMed

    Mitsuboshi, Masahiro; Kioka, Yuuzou; Noguchi, Katsunori; Asakawa, Susumu

    2016-09-29

    Soil-borne diseases caused by pathogenic microorganisms are one of the main factors responsible for the decline in crop yields in farmlands. Pathogenic Fusarium oxysporum causes serious damage to various crops, and, thus, a feasible diagnostic method for soil-borne diseases is required. We herein examined a simple method to evaluate the suppressiveness of soil microorganisms against a pathogen by co-cultivating indigenous soil microorganisms and a pathogenic fungus (F. oxysporum f. sp. spinaciae). We inoculated F. oxysporum onto the center of agar medium plates mixed with a dilution series of a suspension of organic fertilizers or soil. After an approximately one-week cultivation, the growth degree of F. oxysporum was estimated based on the size of the colonies that formed on the plates. The growth degree of F. oxysporum significantly differed among the organic fertilizers tested, indicating the usefulness of the method for evaluating suppressiveness by organic fertilizers. Differences in the growth degrees of F. oxysporum were associated with the incidence of disease in spinach on soil treated with organic fertilizers and inoculated with a pathogenic F. oxysporum strain. These results suggested that this method provides some useful information on the suppressiveness of organic fertilizers and soil against Fusarium wilt.

  18. Agar-block microcosms for controlled plant tissue decomposition by aerobic fungi.

    PubMed

    Schilling, Jonathan S; Jacobson, K Brook

    2011-02-03

    The two principal methods for studying fungal biodegradation of lignocellulosic plant tissues were developed for wood preservative testing (soil-block; agar-block). It is well-accepted that soil-block microcosms yield higher decay rates, fewer moisture issues, lower variability among studies, and higher thresholds of preservative toxicity. Soil-block testing is thus the more utilized technique and has been standardized by American Society for Testing and Materials (ASTM) (method D 1413-07). The soil-block design has drawbacks, however, using locally-variable soil sources and in limiting the control of nutrients external (exogenous) to the decaying tissues. These drawbacks have emerged as a problem in applying this method to other, increasingly popular research aims. These modern aims include degrading lignocellulosics for bioenergy research, testing bioremediation of co-metabolized toxics, evaluating oxidative mechanisms, and tracking translocated elements along hyphal networks. Soil-blocks do not lend enough control in these applications. A refined agar-block approach is necessary. Here, we use the brown rot wood-degrading fungus Serpula lacrymans to degrade wood in agar-block microcosms, using deep Petri dishes with low-calcium agar. We test the role of exogenous gypsum on decay in a time-series, to demonstrate the utility and expected variability. Blocks from a single board rip (longitudinal cut) are conditioned, weighed, autoclaved, and introduced aseptically atop plastic mesh. Fungal inoculations are at each block face, with exogenous gypsum added at interfaces. Harvests are aseptic until the final destructive harvest. These microcosms are designed to avoid block contact with agar or Petri dish walls. Condensation is minimized during plate pours and during incubation. Finally, inoculum/gypsum/wood spacing is minimized but without allowing contact. These less technical aspects of agar-block design are also the most common causes of failure and the key source of

  19. Comparison of Fecal Coliform Agar and Violet Red Bile Lactose Agar for Fecal Coliform Enumeration in Foods

    PubMed Central

    Leclercq, A.; Wanegue, C.; Baylac, P.

    2002-01-01

    A 24-h direct plating method for fecal coliform enumeration with a resuscitation step (preincubation for 2 h at 37 ± 1°C and transfer to 44 ± 1°C for 22 h) using fecal coliform agar (FCA) was compared with the 24-h standardized violet red bile lactose agar (VRBL) method. FCA and VRBL have equivalent specificities and sensitivities, except for lactose-positive non-fecal coliforms such as Hafnia alvei, which could form typical colonies on FCA and VRBL. Recovery of cold-stressed Escherichia coli in mashed potatoes on FCA was about 1 log unit lower than that with VRBL. When the FCA method was compared with standard VRBL for enumeration of fecal coliforms, based on counting carried out on 170 different food samples, results were not significantly different (P > 0.05). Based on 203 typical identified colonies selected as found on VRBL and FCA, the latter medium appears to allow the enumeration of more true fecal coliforms and has higher performance in certain ways (specificity, sensitivity, and negative and positive predictive values) than VRBL. Most colonies clearly identified on both media were E. coli and H. alvei, a non-fecal coliform. Therefore, the replacement of fecal coliform enumeration by E. coli enumeration to estimate food sanitary quality should be recommended. PMID:11916678

  20. A comparison of a new centrifuge sugar flotation technique with the agar method for the extraction of immature Culicoides (Diptera: Ceratopogonidae) life stages from salt marsh soils.

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Two sampling techniques, agar extraction (AE) and centrifuge sugar flotation extraction (CSFE) were compared to determine their relative efficacy to recover immature stages of Culicoides spp from salt marsh substrates. Three types of samples (seeded with known numbers of larvae, homogenized field s...

  1. Comparative evaluation of chromogenic agar medium and conventional culture system for isolation and presumptive identification of uropathogens

    PubMed Central

    Akter, Laila; Haque, Rezwana; Salam, Md. Abdus

    2014-01-01

    Objective: Urine is the most frequent specimen received for culture/sensitivity by clinical laboratories. The microbiological performance of HiCrome UTI agar medium was compared with Blood agar and MacConkey agar for isolation and presumptive identification of bacteria from urine culture. Methods: A total of 443 consecutively collected midstream and/or catheter-catch urine samples from patients attending the Islami Bank Medical College Hospital, Rajshahi, Bangladesh during January to December, 2012 were cultured. Urine samples showing pus cells ≥ 5/HPF were inoculated on to Blood agar (BA), MacConkey agar (MAC) and HiCrome UTI agar (CA) media simultaneously and incubated overnight aerobically at 370C. Rate of isolation and presumptive identification of bacterial species were compared for different media. Results: Culture yielded a total of 199 bacterial isolates from 189 (42.67%) positive plates including 179 (40.40%) unimicrobial and 10 (2.26%) polymicrobial (mixed growth of pair of bacteria) growths. Both HiCrome UTI agar and Blood agar media supported 100% growths while 151 (75.88%) growths were observed on MacConkey agar. The rate of presumptive identification was found significantly higher on HiCrome UTI agar (97.49%) than MAC agar (67.34%) (P<0.001) as primary urine culture medium. Of 199 isolates, E. coli was found to be the leading uropathogen isolated from 118 (59.30%) samples with its presumptive identification rate of 95.76%, 93.22% and 5.93% on CA, MAC and BA respectively. All 10 (100%) polymicrobial growths were demonstrated distinctly on CA against only 01(10%) on each BA and MAC. Conclusion: HiCrome UTI agar was found to be more useful as primary urine culture medium in both higher rate of isolation and presumptive identification of uropathogens in comparison to conventional media. Its inherent characteristics in demonstrating polymicrobial growth and ease of rapid identification by distinct colony colour are unique. PMID:25225521

  2. Models of convection-driven tectonic plates - A comparison of methods and results

    NASA Technical Reports Server (NTRS)

    King, Scott D.; Gable, Carl W.; Weinstein, Stuart A.

    1992-01-01

    Recent numerical studies of convection in the earth's mantle have included various features of plate tectonics. This paper describes three methods of modeling plates: through material properties, through force balance, and through a thin power-law sheet approximation. The results obtained are compared using each method on a series of simple calculations. From these results, scaling relations between the different parameterizations are developed. While each method produces different degrees of deformation within the surface plate, the surface heat flux and average plate velocity agree to within a few percent. The main results are not dependent upon the plate modeling method and herefore are representative of the physical system modeled.

  3. Strongyloides stercoralis: a field-based survey of mothers and their preschool children using ELISA, Baermann and Koga plate methods reveals low endemicity in western Uganda.

    PubMed

    Stothard, J R; Pleasant, J; Oguttu, D; Adriko, M; Galimaka, R; Ruggiana, A; Kazibwe, F; Kabatereine, N B

    2008-09-01

    To ascertain the current status of strongyloidiasis in mothers and their preschool children, a field-based survey was conducted in western Uganda using a combination of diagnostic methods: ELISA, Baermann concentration and Koga agar plate. The prevalence of other soil-transmitted helminthiasis and intestinal schistosomiasis were also determined. In total, 158 mothers and 143 children were examined from five villages within Kabale, Hoima and Masindi districts. In mothers and children, the general prevalence of strongyloidiasis inferred by ELISA was approximately 4% and approximately 2%, respectively. Using the Baermann concentration method, two parasitologically proven cases were encountered in an unrelated mother and child, both of whom were sero-negative for strongyloidiasis. No infections were detected by Koga agar plate method. The general level of awareness of strongyloidiasis was very poor ( < 5%) in comparison to schistosomiasis (51%) and ascariasis (36%). Strongyloidiasis is presently at insufficient levels to justify inclusion within a community treatment programme targeting maternal and child health. Better epidemiological screening is needed, however, especially identifying infections in HIV-positive women of childbearing age. In the rural clinic setting, further use of the Baermann concentration method would appear to be the most immediate and pragmatic option for disease diagnosis.

  4. Method for Reduction of Silver Biocide Plating on Metal Surfaces

    NASA Technical Reports Server (NTRS)

    Steele, John; Nalette, Timothy; Beringer, Durwood

    2013-01-01

    Silver ions in aqueous solutions (0.05 to 1 ppm) are used for microbial control in water systems. The silver ions remain in solution when stored in plastic containers, but the concentration rapidly decreases to non-biocidal levels when stored in metal containers. The silver deposits onto the surface and is reduced to non-biocidal silver metal when it contacts less noble metal surfaces, including stainless steel, titanium, and nickel-based alloys. Five methods of treatment of contact metal surfaces to deter silver deposition and reduction are proposed: (1) High-temperature oxidation of the metal surface; (2) High-concentration silver solution pre-treatment; (3) Silver plating; (4) Teflon coat by vapor deposition (titanium only); and (5) A combination of methods (1) and (2), which proved to be the best method for the nickel-based alloy application. The mechanism associated with surface treatments (1), (2), and (5) is thought to be the development of a less active oxide layer that deters ionic silver deposition. Mechanism (3) is an attempt to develop an equilibrium ionic silver concentration via dissolution of metallic silver. Mechanism (4) provides a non-reactive barrier to deter ionic silver plating. Development testing has shown that ionic silver in aqueous solution was maintained at essentially the same level of addition (0.4 ppm) for up to 15 months with method (5) (a combination of methods (1) and (2)), before the test was discontinued for nickel-based alloys. Method (1) resulted in the maintenance of a biocidal level (approximately 0.05 ppm) for up to 10 months before that test was discontinued for nickel-based alloys. Methods (1) and (2) used separately were able to maintain ionic silver in aqueous solution at essentially the same level of addition (0.4 ppm) for up to 10 months before the test was discontinued for stainless steel alloys. Method (3) was only utilized for titanium alloys, and was successful at maintaining ionic silver in aqueous solution at

  5. Antimicrobial Susceptibility of Flavobacterium psychrophilum from Chilean Salmon Farms and Their Epidemiological Cut-Off Values Using Agar Dilution and Disk Diffusion Methods

    PubMed Central

    Miranda, Claudio D.; Smith, Peter; Rojas, Rodrigo; Contreras-Lynch, Sergio; Vega, J. M. Alonso

    2016-01-01

    Flavobacterium psychrophilum is the most important bacterial pathogen for freshwater farmed salmonids in Chile. The aims of this study were to determine the susceptibility to antimicrobials used in fish farming of Chilean isolates and to calculate their epidemiological cut-off (COWT) values. A number of 125 Chilean isolates of F. psychrophilum were isolated from reared salmonids presenting clinical symptoms indicative of flavobacteriosis and their identities were confirmed by 16S rRNA polymerase chain reaction. Susceptibility to antibacterials was tested on diluted Mueller-Hinton by using an agar dilution MIC method and a disk diffusion method. The COWT values calculated by Normalized Resistance Interpretation (NRI) analysis allow isolates to be categorized either as wild-type fully susceptible (WT) or as manifesting reduced susceptibility (NWT). When MIC data was used, NRI analysis calculated a COWT of ≤0.125, ≤2, and ≤0.5 μg mL-1 for amoxicillin, florfenicol, and oxytetracycline, respectively. For the quinolones, the COWT were ≤1, ≤0.5, and ≤0.125 μg mL-1 for oxolinic acid, flumequine, and enrofloxacin, respectively. The disk diffusion data sets obtained in this work were extremely diverse and were spread over a wide range. For the quinolones there was a close agreement between the frequencies of NWT isolates calculated using MIC and disk data. For oxolinic acid, flumequine, and enrofloxacin the frequencies were 45, 39, and 38% using MIC data, and 42, 41, and 44%, when disk data were used. There was less agreement with the other antimicrobials, because NWT frequencies obtained using MIC and disk data, respectively, were 24 and 10% for amoxicillin, 8 and 2% for florfenicol, and 70 and 64% for oxytetracycline. Considering that the MIC data was more precise than the disk diffusion data, MIC determination would be the preferred method for susceptibility testing for this species and the NWT frequencies derived from the MIC data sets should be considered

  6. Antimicrobial Susceptibility of Flavobacterium psychrophilum from Chilean Salmon Farms and Their Epidemiological Cut-Off Values Using Agar Dilution and Disk Diffusion Methods.

    PubMed

    Miranda, Claudio D; Smith, Peter; Rojas, Rodrigo; Contreras-Lynch, Sergio; Vega, J M Alonso

    2016-01-01

    Flavobacterium psychrophilum is the most important bacterial pathogen for freshwater farmed salmonids in Chile. The aims of this study were to determine the susceptibility to antimicrobials used in fish farming of Chilean isolates and to calculate their epidemiological cut-off (COWT) values. A number of 125 Chilean isolates of F. psychrophilum were isolated from reared salmonids presenting clinical symptoms indicative of flavobacteriosis and their identities were confirmed by 16S rRNA polymerase chain reaction. Susceptibility to antibacterials was tested on diluted Mueller-Hinton by using an agar dilution MIC method and a disk diffusion method. The COWT values calculated by Normalized Resistance Interpretation (NRI) analysis allow isolates to be categorized either as wild-type fully susceptible (WT) or as manifesting reduced susceptibility (NWT). When MIC data was used, NRI analysis calculated a COWT of ≤0.125, ≤2, and ≤0.5 μg mL(-1) for amoxicillin, florfenicol, and oxytetracycline, respectively. For the quinolones, the COWT were ≤1, ≤0.5, and ≤0.125 μg mL(-1) for oxolinic acid, flumequine, and enrofloxacin, respectively. The disk diffusion data sets obtained in this work were extremely diverse and were spread over a wide range. For the quinolones there was a close agreement between the frequencies of NWT isolates calculated using MIC and disk data. For oxolinic acid, flumequine, and enrofloxacin the frequencies were 45, 39, and 38% using MIC data, and 42, 41, and 44%, when disk data were used. There was less agreement with the other antimicrobials, because NWT frequencies obtained using MIC and disk data, respectively, were 24 and 10% for amoxicillin, 8 and 2% for florfenicol, and 70 and 64% for oxytetracycline. Considering that the MIC data was more precise than the disk diffusion data, MIC determination would be the preferred method for susceptibility testing for this species and the NWT frequencies derived from the MIC data sets should be

  7. Campylobacter in broiler slaughter samples assessed by direct count on mCCDA and Campy-Cefex agar.

    PubMed

    Gonsalves, Camila Cristina; Borsoi, Anderlise; Perdoncini, Gustavo; Rodrigues, Laura Beatriz; do Nascimento, Vladimir Pinheiro

    2016-01-01

    Campylobacter spp. cause foodborne illnesses in humans primarily through the consumption of contaminated chicken. The aim of this study was to evaluate the United States Department of Agriculture's (USDA) recommended methodology, protocol MLG 41.02, for the isolation, identification and direct plate counting of Campylobacter jejuni and C. coli samples from the broiler slaughtering process. A plating method using both mCCDA and Campy-Cefex agars is recommended to recover Campylobacter cells. It is also possible to use this method in different matrices (cloacal swabs and water samples). Cloacal swabs, samples from pre-chiller and post-chiller carcasses and samples of pre-chiller, chiller and direct supply water were collected each week for four weeks from the same flock at a slaughterhouse located in an abattoir in southern Brazil. Samples were analyzed to directly count Campylobacter spp., and the results showed a high frequency of Campylobacter spp. on Campy-Cefex agar. For the isolated species, 72% were identified as Campylobacter jejuni and 38% as Campylobacter coli. It was possible to count Campylobacter jejuni and Campylobacter coli from different samples, including the water supply samples, using the two-agar method. These results suggest that slaughterhouses can use direct counting methods with both agars and different matrices as a monitoring tool to assess the presence of Campylobacter bacteria in their products.

  8. Abilities of the mCP Agar method and CRENAME alpha toxin-specific real-time PCR assay to detect Clostridium perfringens spores in drinking water.

    PubMed

    Maheux, Andrée F; Bérubé, Eve; Boudreau, Dominique K; Villéger, Romain; Cantin, Philippe; Boissinot, Maurice; Bissonnette, Luc; Bergeron, Michel G

    2013-12-01

    We first determined the analytical specificity and ubiquity (i.e., the ability to detect all or most strains) of a Clostridium perfringens-specific real-time PCR (rtPCR) assay based on the cpa gene (cpa rtPCR) by using a bacterial strain panel composed of C. perfringens and non-C. perfringens Clostridium strains. All non-C. perfringens Clostridium strains tested negative, whereas all C. perfringens strains tested positive with the cpa rtPCR, for an analytical specificity and ubiquity of 100%. The cpa rtPCR assay was then used to confirm the identity of 116 putative C. perfringens isolates recovered after filtration of water samples and culture on mCP agar. Colonies presenting discordant results between the phenotype on mCP agar and cpa rtPCR were identified by sequencing the 16S rRNA and cpa genes. Four mCP(-)/rtPCR(+) colonies were identified as C. perfringens, whereas 3 mCP(+)/rtPCR(-) colonies were identified as non-C. perfringens. The cpa rtPCR was negative with all 51 non-C. perfringens strains and positive with 64 of 65 C. perfringens strains. Finally, we compared mCP agar and a CRENAME (concentration and recovery of microbial particles, extraction of nucleic acids, and molecular enrichment) procedure plus cpa rtPCR (CRENAME + cpa rtPCR) for their abilities to detect C. perfringens spores in drinking water. CRENAME + cpa rtPCR detected as few as one C. perfringens CFU per 100 ml of drinking water sample in less than 5 h, whereas mCP agar took at least 25 h to deliver results. CRENAME + cpa rtPCR also allows the simultaneous and sensitive detection of Escherichia coli and C. perfringens from the same potable water sample. In itself, it could be used to assess the public health risk posed by drinking water potentially contaminated with pathogens more resistant to disinfection.

  9. Ionometric methods used in process control of noble metal plating electrolytes

    SciTech Connect

    Ermolaeva, M.N.; Grekovich, A.L.; Vinogradova, V.P.

    1995-11-01

    Ion-selective electrodes used for the analysis of gold in citrate and cyanide gold plating electrolytes and of silver and cyanide ions in silver plating electrolytes are described. Methods for process control of dicyanoaurate, dicyanoargentate, and cyanide ions in plating electrolytes used in jewelry manufacturing, are presented.

  10. Optimum Design of Stiffened Plates Using the Finite Element Method.

    DTIC Science & Technology

    1983-03-01

    that displace- ments are small compared with plate thickness, the stress normal to the midsurface of the plate is negligible, and normals to the... midsurface before deformation remain straight but not necessarily normal to the midsurface after deformation. The assumed displacement functions will be taken

  11. Radiation survival of murine and human melanoma cells utilizing two assay systems: monolayer and soft agar.

    PubMed Central

    Yohem, K. H.; Slymen, D. J.; Bregman, M. D.; Meyskens, F. L.

    1988-01-01

    The radiation response of murine and human melanoma cells assayed in bilayer soft agar and monolayer was examined. Cells from the murine melanoma Cloudman S91 CCL 53.1 cell line and three human melanoma cell strains (C8146C, C8161, and R83-4) developed in our laboratory were irradiated by single dose X-rays and plated either in agar or on plastic. D0 values were the same within 95% confidence intervals for cells from the human melanoma cell strains C8146C, C8161, and R83-4 but were dissimilar for the murine cell line CCL 53.1 Dq values were different for all cells studied. The shape of the survival curve for all four melanomas was not identical for cells assayed in soft agar versus cells grown on plastic. This would indicate that apparent radiosensitivity was influenced by the method of assay although there were no apparent consistent differences between the curves generated by monolayer or bilayer soft agar assays. PMID:3348949

  12. A location method for vehicle license plate based on color image and black-white texture

    NASA Astrophysics Data System (ADS)

    Li, Gang; Liu, Chang; He, Mingquan; Huang, Xiyue

    2007-12-01

    This paper presents an effective location algorithm employing color features and black-white texture analysis of the image to extract a vehicle license plate from a complicated background image. According to the background color of the license plate in RGB spaces, we transform the RGB image into a grayscale image as strengthening the color of the license plate, and partition the intensity image to obtain a binary image which can outstand the license plate part. We leach away the color which is similar to the license plate by analyzing the texture characteristic. The test shows that this location method can hardly be influenced by all of the factors including illumination, license plate position, license plate size, license plate angle, car position, image background and so on. Meanwhile, it can gain a high speed, better effects and a wide application area.

  13. Hydrophobic grid membrane filter method for aerobic plate count in foods: collaborative study.

    PubMed

    Entis, P

    1986-01-01

    Twenty-one laboratories participated in a collaborative study to validate a hydrophobic grid membrane filter (HGMF) method for aerobic plate count by comparing its performance against the AOAC/APHA pour plate method. Raw milk, raw poultry, whole egg powder, flours, and spices were included in the study. Counts obtained by the HGMF and pour plate methods did not differ significantly, except in the case of whole egg powder, for which the HGMF method produced significantly higher counts. The hydrophobic grid membrane filter method for aerobic plate count in foods has been adopted official first action.

  14. Perforated plates for cryogenic regenerators and method of fabrication

    DOEpatents

    Hendricks, J.B.

    1994-03-29

    Perforated plates having very small holes with a uniform diameter throughout the plate thickness are prepared by a [open quotes]wire drawing[close quotes] process in which a billet of sacrificial metal is disposed in an extrusion can of the plate metal, and the can is extruded and restacked repeatedly, converting the billet to a wire of the desired hole diameter. At final size, the rod is then sliced into wafers, and the wires are removed by selective etching. This process is useful for plate metals of interest for high performance regenerator applications, in particular, copper, niobium, molybdenum, erbium, and other rare earth metals. Er[sub 3]Ni, which has uniquely favorable thermophysical properties for such applications, may be incorporated in regions of the plates by providing extrusion cans containing erbium and nickel metals in a stacked array with extrusion cans of the plate metal, which may be copper. The array is heated to convert the erbium and nickel metals to Er[sub 3]Ni. Perforated plates having two sizes of perforations, one of which is small enough for storage of helium, are also disclosed. 10 figures.

  15. Perforated plates for cryogenic regenerators and method of fabrication

    DOEpatents

    Hendricks, John B.

    1994-01-01

    Perforated plates (10) having very small holes (14) with a uniform diameter throughout the plate thickness are prepared by a "wire drawing" process in which a billet of sacrificial metal is disposed in an extrusion can of the plate metal, and the can is extruded and restacked repeatedly, converting the billet to a wire of the desired hole diameter. At final size, the rod is then sliced into wafers, and the wires are removed by selective etching. This process is useful for plate metals of interest for high performance regenerator applications, in particular, copper, niobium, molybdenum, erbium, and other rare earth metals. Er.sub.3 Ni, which has uniquely favorable thermophysical properties for such applications, may be incorporated in regions of the plates by providing extrusion cans (20) containing erbium and nickel metals in a stacked array (53) with extrusion cans of the plate metal, which may be copper. The array is heated to convert the erbium and nickel metals to Er.sub.3 Ni. Perforated plates having two sizes of perforations (38, 42), one of which is small enough for storage of helium, are also disclosed.

  16. Direct identification and recognition of yeast species from clinical material by using albicans ID and CHROMagar Candida plates.

    PubMed Central

    Baumgartner, C; Freydiere, A M; Gille, Y

    1996-01-01

    Two chromogenic media, Albicans ID and CHROMagar Candida agar plates, were compared with a reference medium, Sabouraud-chloramphenicol agar, and standard methods for the identification of yeast species. This study involved 951 clinical specimens. The detection rates for the two chromogenic media for polymicrobial specimens were 20% higher than that for the Sabouraud-chloramphenicol agar plates. The rates of identification of Candida albicans for Albicans ID and CHROMagar Candida agar plates were, respectively, 37.0 and 6.0% after 24 h of incubation and 93.6 and 92.2% after 72 h of incubation, with specificities of 99.8 and 100%. Furthermore, CHROMagar Candida plates identified 13 of 14 Candida tropicalis and 9 of 12 Candida krusei strains after 48 h of incubation. PMID:8789038

  17. Radioisotopic quantitation in microtitration plates by an autofluorographic method.

    PubMed

    Freshney, R I; Morgan, D

    1978-07-01

    An autofluorographic record of drug titrations in microtitration plates has been obtained using cultures labelled with [35s] methionine after treatment with cytostatic drugs. By adding scintillation fluid directly to each culture well of the microtitration plate, and then centrifuging the evaporate the toluene and leave a flat even film of fluor, in situ scintillation is produced. When X-ray film is exposed to the plate the scintillation of individual wells is recorded as spots on the film. These may be interpreted by eye or by scanning densitometry.

  18. A comparison of two methods for isolation of Salmonella from poultry litter samples.

    PubMed

    Read, S C; Irwin, R J; Poppe, C; Harris, J

    1994-10-01

    Two methods were compared to determine their ability and efficiency in detecting Salmonella in poultry litter samples. Method 1 consisted of pre-enrichment in buffered peptone water (BPW), selective motility enrichment in Modified Semisolid Rappaport Vassiliadis (MSRV) agar, and plating onto MacConkey (MC) agar. Method 2 employed tetrathionate brilliant green (TBG) broth and plating on brilliant green agar with novobiocin (BGAN) and on xylose lysine tergitol 4 (XLT4) agar. Method 1 resulted in a significantly higher isolation rate, was cheaper, and was less labor intensive.

  19. Method for regeneration of electroless nickel plating solution

    DOEpatents

    Eisenmann, Erhard T.

    1997-01-01

    An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorous acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution.

  20. Method for regeneration of electroless nickel plating solution

    DOEpatents

    Eisenmann, E.T.

    1997-03-11

    An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorus acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution. 1 fig.

  1. Method and apparatus for enhancing microchannel plate data

    DOEpatents

    Thoe, R.S.

    1983-10-24

    A method and apparatus for determining centroid channel locations are disclosed for use in a system activated by one or more multichannel plates and including a linear diode array providing channels of information 1, 2, ...,n, ..., N containing signal amplitudes A/sub n/. A source of analog A/sub n/ signals, and a source of digital clock signals n, are provided. Non-zero A/sub n/ values are detected in a discriminator. A digital signal representing p, the value of n immediately preceding that whereat A/sub n/ takes its first non-zero value, is generated in a scaler. The analog A/sub n/ signals are converted to digital in an analog to digital converter. The digital A/sub n/ signals are added to produce a digital ..sigma..A/sub n/ signal in a full adder. Digital 1, 2, ..., m signals representing the number of non-zero A/sub n/ are produced by a discriminator pulse counter. Digital signals representing 1 A/sub p+1/, 2 A/sub p+2/, ..., m A/sub p+m/ are produced by pairwise multiplication in multiplier. These signal are added in multiplier summer to produce a digital ..sigma..nA/sub n/ - p..sigma..A/sub n/ signal. This signal is divided by the digital ..sigma..A/sub n/ signal in divider to provide a digital (..sigma..nA/sub n//..sigma..A/sub n/) -p signal. Finally, this last signal is added to the digital p signal in an offset summer to provide ..sigma..nA/sub n//..sigma..A/sub n/, the centroid channel locations.

  2. Method and apparatus for enhancing microchannel plate data

    DOEpatents

    Thoe, Robert S.

    1987-01-01

    A method and apparatus for determining centroid channel locations is disclosed for use in a system activated by one or more multichannel plates (16,18) and including a linear diode array (24) providing channels of information 1, 2, . . . , n, . . . , N containing signal amplitudes A.sub.n. A source of analog A.sub.n signals (40), and a source of digital clock signals n (48), are provided. Non-zero A.sub.n values are detected in a discriminator (42). A digital signal representing p, the value of n immediately preceding that whereat A.sub.n takes its first non-zero value, is generated in a scaler (50). The analog A.sub.n signals are converted to digital in an analog to digital converter (44). The digital A.sub.n signals are added to produce a digital .SIGMA.A.sub.n signal in a full adder (46). Digital 1, 2, . . . , m signals representing the number of non-zero A.sub.n are produced by a discriminator pulse counter (52). Digital signals representing 1 A.sub.p+ 1, 2 A.sub.p+2, . . . , m A.sub.p+m are produced by pairwise multiplication in multiplier (54). These signals are added in multiplier summer (56) to produce a digital .SIGMA.nA.sub.n -p.SIGMA.A.sub.n signal. This signal is divided by the digital .SIGMA.A.sub.n signal in divider (58) to provide a digital (.SIGMA.nA.sub.n /.SIGMA.A.sub.n) -p signal. Finally, this last signal is added to the digital p signal in an offset summer (60) to provide .SIGMA.nA.sub.n /.SIGMA.A.sub.n, the centroid channel locations.

  3. Biomechanical evaluation of the fixation methods for transcondylar fracture of the humerus:ONI plate versus conventional plates and screws.

    PubMed

    Shimamura, Yasunori; Nishida, Keiichiro; Imatani, Junya; Noda, Tomoyuki; Hashizume, Hiroyuki; Ohtsuka, Aiji; Ozaki, Toshifumi

    2010-04-01

    We biomechanically evaluated the bone fixation rigidity of an ONI plate (Group I) during fixation of experimentally created transcondylar humerus fractures in cadaveric elbows, which are the most frequently observed humeral fractures in the elderly, and compared it with the rigidity achieved by 3 conventional fixation methods:an LCP reconstruction plate 3.5 using a locking mechanism (Group II), a conventional reconstruction plate 3.5 (CRP) with a cannulated cancellous screw (Group III), and a CRP with 2 cannulated cancellous screws (CS) in a crisscross orientation (Group IV). In the axial loading test, the mean failure loads were:Group I, 98.9+/-32.6;Group II, 108.5+/-27.2;Group III, 50.0+/-7.5;and Group IV, 34.5+/-12.2 (N). Group I fixations failed at a significantly higher load than those of Groups III and IV (p<0.05). In the extension loading test, the mean failure loads were:Group I, 34.0+/-12.4;Group II, 51.0+/-14.8;Group III, 19.3+/-6.0;and Group IV, 14.7+/-3.1 (N). Group IV fixations showed a significantly lower failure load than those of Group I (p<0.05). The fixation rigidities against mechanical loading by the ONI plate and LCP plate were comparable. These results suggested that an ONI system might be superior to the CRP and CS method, and comparable to the LCP method in terms of fixation rigidity for distal humerus fractures.

  4. Fuel cell collector plate and method of fabrication

    DOEpatents

    Braun, James C.; Zabriskie, Jr., John E.; Neutzler, Jay K.; Fuchs, Michel; Gustafson, Robert C.

    2001-01-01

    An improved molding composition is provided for compression molding or injection molding a current collector plate for a polymer electrolyte membrane fuel cell. The molding composition is comprised of a polymer resin combined with a low surface area, highly-conductive carbon and/or graphite powder filler. The low viscosity of the thermoplastic resin combined with the reduced filler particle surface area provide a moldable composition which can be fabricated into a current collector plate having improved current collecting capacity vis-a-vis comparable fluoropolymer molding compositions.

  5. Method for in-situ nondestructive measurement of Young's modulus of plate structures

    NASA Technical Reports Server (NTRS)

    Huang, Jerry Qixin (Inventor); Perez, Robert J. (Inventor); DeLangis, Leo M. (Inventor)

    2003-01-01

    A method for determining stiffness of a composite laminate plate entails disposing a device for generating an acoustical pulse against a surface of the plate and disposing a detecting device against the same surface spaced a known distance from the pulse-generating device, and using the pulse-generating device to emit a pulse so as to create an extensional wave in the plate. The detecting device is used to determine a time of flight of the wave over the known distance, and the wave velocity is calculated. A Young's modulus of the plate is determined based on the wave velocity. Methods for both anisotropic and quasi-isotropic laminates are disclosed.

  6. gitter: a robust and accurate method for quantification of colony sizes from plate images.

    PubMed

    Wagih, Omar; Parts, Leopold

    2014-03-20

    Colony-based screens that quantify the fitness of clonal populations on solid agar plates are perhaps the most important source of genome-scale functional information in microorganisms. The images of ordered arrays of mutants produced by such experiments can be difficult to process because of laboratory-specific plate features, morphed colonies, plate edges, noise, and other artifacts. Most of the tools developed to address this problem are optimized to handle a single setup and do not work out of the box in other settings. We present gitter, an image analysis tool for robust and accurate processing of images from colony-based screens. gitter works by first finding the grid of colonies from a preprocessed image and then locating the bounds of each colony separately. We show that gitter produces comparable colony sizes to other tools in simple cases but outperforms them by being able to handle a wider variety of screens and more accurately quantify colony sizes from difficult images. gitter is freely available as an R package from http://cran.r-project.org/web/packages/gitter under the LGPL. Tutorials and demos can be found at http://omarwagih.github.io/gitter.

  7. Method of obtaining intensified image from developed photographic films and plates

    NASA Technical Reports Server (NTRS)

    Askins, B. S. (Inventor)

    1978-01-01

    A method is explained of obtaining intensified images from silver images on developed photographic films and plates. The steps involve converting silver of the developed film or plate to a radioactive compound by treatment with an aqueous alkaline solution of an organo-S35 compound; placing the treated film or plate in direct contact with a receiver film which is then exposed by radiation from the activated film; and developing and fixing the resulting intensified image on the receiver film.

  8. Evaluation of Mueller-Hinton-agar as a simple medium for the germ tube production of Candida albicans and Candida dubliniensis.

    PubMed

    Rimek, Dagmar; Fehse, Brigitte; Göpel, Petra

    2008-05-01

    Candida albicans is the most frequently isolated yeast species from clinical specimens. A classical rapid presumptive differentiation from non-albicans species is based on its ability to produce germ tubes after incubation in human serum. The only non-albicans Candida species producing germ tubes is Candida dubliniensis. In this study, we evaluated Mueller-Hinton-agar (MH-agar) as a medium for germ tube formation of C. albicans and C. dubliniensis. A total of 859 yeast isolates from stool samples, including 632 strains of C. albicans, 10 C. dubliniensis and 217 other yeast strains from 20 different species, were grown on Sabouraud glucose (2%) agar at 37 degrees C for 24-72 h. Species were identified by standard methods. For the germ tube test (GTT), an inoculum from a single colony was streaked onto a MH-agar plate and covered by a sterile coverslip. After incubation at 37 degrees C for 2 h, the MH plates were examined using a light microscope at x200. The GTT was positive in 578 of 632 C. albicans strains (sensitivity 91.5%), in six of 10 C. dubliniensis strains (sensitivity 60.0%), and in none of the other yeast strains. MH-agar is a suitable medium for the GTT and the presumptive identification of C. albicans. It is safer to use than human serum and is widely available in microbiology laboratories.

  9. Screening for antimicrobial resistance in normal bacterial flora of the skin using the replica plating method.

    PubMed

    Paavilainen, T; Osterblad, M; Leistevuo, T; Huovinen, P; Kotilainen, P

    2000-12-01

    The replica plating method was evaluated for detection of the antimicrobial resistance of normal bacterial flora of the skin and was compared with the results of a ten-colony method. If > or = 10% of the colonies from the master plate grew on a plate containing an antibiotic, the sensitivity of replica plating was comparable to that of a ten-colony method for samples containing resistant bacteria. However, this method classified significantly more samples as resistant to all eight antibiotics tested if the detection breakpoint was lowered to > or = 1% of the original colonies. Replica plating is an effective and practical tool for screening skin flora for resistance, also in samples with a low proportion of resistant strains.

  10. Progressive Failure Analysis of Laminated Composite Plates with Elliptical or Circular Cutout Using Finite Element Method

    NASA Astrophysics Data System (ADS)

    Lakshminarayana, A.; Vijayakumar, R.; Krishnamohana Rao, G.

    2016-09-01

    The progressive failure analysis of symmetrically laminated composite plate [0°/+45°/-45°/90°]2s with circular or elliptical cutout under uniform uniaxial compression loading is carried out using finite element method. Hashin's failure criterion is used to predict the lamina failure. A parametric study has been carried out to study the effect of elliptical / circular cutout orientation, cutout size and plate thickness on the ultimate failure load of laminated composite plate under uni-axial compression loading. It is noticed that elliptical cutout orientation has influence on the strength of the notched composite plates. It is observed that the laminate size of the elliptical/circular cutout and plate thickness has substantial influence on the ultimate failure load of notched composite plates.

  11. Does elevating silver content in zinc-based glass polyalkenoate cements increase their antibacterial efficacy against two common bacteria using the agar gel diffusion method?

    PubMed

    Coughlan, A; Breed, S M; Ashraf, C; Cardinale, J A; Hall, M M; Towler, M R

    2013-03-01

    The authors have previously shown that it is possible to incorporate silver into a soda-zinc-silicate glass and subsequently form a glass polyalkenoate cement from it. The objective of the research described herein is to determine if incremental increases in the silver content of these glass polyalkenoate cements will increase their antibacterial efficacy against gram-positive and gram-negative bacteria using the accepted spread plate method. Four glass polyalkenoate cements were formulated; three contained increasing amounts of silver incorporated into them (cements A, B, and C, containing 0.33 mol%, 0.66 mol%, and 0.99 mol% silver, respectively) and a fourth contained no silver, which acted as a control (control cement). The handling properties of the glass polyalkenoate cements were evaluated, where working times were around 2 min and setting times ranged from 1 h 17 min to 2 h 41 min. Inductively coupled plasma atomic emission spectroscopy was employed to determine silver ion release with cement maturation for up to 14 days. The majority of silver ions were released within the first 24 h, with up to 2 mg/L cumulative ion release recorded up to 14 days. The antibacterial properties of the coatings were evaluated against Staphylococcus aureus and Pseudomonas aeruginosa bacteria. The silver-glass polyalkenoate cements exhibited antibacterial effect against both bacterial strains. The maximum inhibition zones recorded against S. aureus was 14.8 mm (SD ± 1.11) and against P. aeruginosa was 20.6 mm (SD ± 0.81). Cement B had a greater antibacterial effect compared to cement A, however, cements B and C had comparable antibacterial effects after 14 days even though cement C contained 0.33 mol% more silver than B. This indicates that by increasing the silver content in these cements, the antibacterial efficacy increases to a point, but there is a threshold where further silver ion release does not increase the antibacterial effect.

  12. The constraint method: A new finite element technique. [applied to static and dynamic loads on plates

    NASA Technical Reports Server (NTRS)

    Tsai, C.; Szabo, B. A.

    1973-01-01

    An approch to the finite element method which utilizes families of conforming finite elements based on complete polynomials is presented. Finite element approximations based on this method converge with respect to progressively reduced element sizes as well as with respect to progressively increasing orders of approximation. Numerical results of static and dynamic applications of plates are presented to demonstrate the efficiency of the method. Comparisons are made with plate elements in NASTRAN and the high-precision plate element developed by Cowper and his co-workers. Some considerations are given to implementation of the constraint method into general purpose computer programs such as NASTRAN.

  13. Simple phase-shifting method in a wedge-plate lateral-shearing interferometer.

    PubMed

    Song, Jae Bong; Lee, Yun Woo; Lee, In Won; Lee, Yong-Hee

    2004-07-10

    A simple phase-shifting method in a wedge-plate lateral shearing interferometer is described. Simply moving the wedge plate in an in-plane parallel direction gives the amount of phase shift required for phase-shifting interferometry because the thickness of a wedge plate is not constant and varies along the wedge direction. This method requires only one additional linear translator to move the wedge plate. The required moving distance for a phase shift of the wave front with this method is of the order of a millimeter, whereas the typical moving distance for another method that uses a piezoelectric transducer is of the order of a wavelength. This method yields better precision in controlling the moving distance than do the other methods.

  14. Chemical plating method of preparing radiation source material

    DOEpatents

    Smith, P.K.; Huntoon, R.T.; Mosley, W.C. Jr.

    1973-12-11

    A uniform dispersion of a radioisotope within a noble metal matrix is provided by chemically plating a noble metal coating onto particles including a dissociable compound of the mdioisotope. A suspension of the dissociable compound in a chemically reductive solution is prepared and noble metal cations added to produce the noble metal coatings. The coated particles are filtered, dried and heated to calcine the dissociable compound to a refractory powder. The powder can be encapsulated in measured portions or consolidated and shaped into an elongated form for easy apportionnnent as radiation source material. (Official Gazette)

  15. A novel method for characterizing the impact response of functionally graded plates

    NASA Astrophysics Data System (ADS)

    Larson, Reid A.

    Functionally graded material (FGM) plates are advanced composites with properties that vary continuously through the thickness of the plate. Metal-ceramic FGM plates have been proposed for use in thermal protection systems where a metal-rich interior surface of the plate gradually transitions to a ceramic-rich exterior surface of the plate. The ability of FGMs to resist impact loads must be demonstrated before using them in high-temperature environments in service. This dissertation presents a novel technique by which the impact response of FGM plates is characterized for low-velocity, low- to medium-energy impact loads. An experiment was designed where strain histories in FGM plates were collected during impact events. These strain histories were used to validate a finite element simulation of the test. A parameter estimation technique was developed to estimate local material properties in the anisotropic, non-homogenous FGM plates to optimize the finite element simulations. The optimized simulations captured the physics of the impact events. The method allows research & design engineers to make informed decisions necessary to implement FGM plates in aerospace platforms.

  16. Zone plate method for electronic holographic display using resolution redistribution technique.

    PubMed

    Takaki, Yasuhiro; Nakamura, Junya

    2011-07-18

    The resolution redistribution (RR) technique can increase the horizontal viewing-zone angle and screen size of electronic holographic display. The present study developed a zone plate method that would reduce hologram calculation time for the RR technique. This method enables calculation of an image displayed on a spatial light modulator by performing additions of the zone plates, while the previous calculation method required performing the Fourier transform twice. The derivation and modeling of the zone plate are shown. In addition, the look-up table approach was introduced for further reduction in computation time. Experimental verification using a holographic display module based on the RR technique is presented.

  17. [Evaluation of a new medium, eggplant (Solanum melongena) agar as a screening medium for Cryptococcus neoformans in environmental samples].

    PubMed

    Sengul, Mustafa; Ergin, Cağrı; Kartal, Tuğba

    2014-04-01

    .neoformans colony forming unit (cfu) per plate were found as 51, 57 and 48 (median values) on simplified Staib agar, Pal's agar and eggplant agar, respectively, while tobacco agar has lower performance with 33 cfu/petri. No statistically significant difference were found between simplified Staib agar, Pal's agar and eggplant agar's performances for C.neoformans isolations from the nature (p=0.71). In conclusion, easily prepared eggplant agar is as functional as widely used media such as simplified Staib agar and Pal's agar for the isolation of C.neoformans from the natural environment.

  18. Development of an eco-friendly agar extraction technique from the red seaweed Gracilaria lemaneiformis.

    PubMed

    Li, Haiyan; Yu, Xingju; Jin, Yan; Zhang, Wei; Liu, Yuanling

    2008-05-01

    The red seaweed, Gracilaria lemaneiformis growing as an aquaculture bioremediator along the coasts of Liaodong Peninsula, China, was investigated for the agar production. An eco-friendly method called agar photobleaching extraction process was developed for the benefit of workers' health and safety of the environment. The native agar (NA), alkali-modified agar (AA), chemical-bleached agar (CA) and photobleached agar (PA), which were extracted using different processes, were evaluated for their physical and chemical properties. The PA showed most desirable performances in terms of gel strength, gelling temperature, sulfate content and 3,6-anhydro-l-galactose content. Among the different processed agars, PA gel strength was 1913 g/cm2, the highest among the different processed agars, which increased 8.6% on the basis of the AA. Further we applied this new technique to extract agars from Gracilaria asiatica, and similar results were obtained with that of G. lemaneiformis. This indicates that the agar photobleaching extraction process is a feasible method for Gracilaria species and has a potential application. During the whole agar photobleaching extraction process the pigment content of G. lemaneiformis declined gradually and the TOC concentration in photobleaching solution increased along with the increase in the irradiation time. The mechanism of agar photobleaching could be elucidated by the photolysis theory.

  19. Biphasic microtiter method for campylobacter recovery and enumeration

    Technology Transfer Automated Retrieval System (TEKTRAN)

    We developed a biphasic method for recovery and enumeration of campylobacters. The biphasic system was composed of 96-well microtiter plates containing Campy-Line Agar (CLA) prepared 2X for all ingredients except for 1X agar (0.1 ml per well). Samples of pure Campylobacter spp. isolates, post-chi...

  20. Isolation method (direct plating or enrichment) does not affect antimicrobial susceptibility of Campylobacter from chicken carcasses

    Technology Transfer Automated Retrieval System (TEKTRAN)

    To determine if Campylobacter isolation method influenced antimicrobial susceptibility results, the minimum inhibitory concentrations (MIC) of nine antimicrobials were compared for 291 pairs of Campylobacter isolates recovered from chicken carcass rinse samples using direct plating and an enrichment...

  1. Orbiter Cold Plate Intergranular Corrosion: Development of NDE Standards and Assessment of NDE Methods

    NASA Technical Reports Server (NTRS)

    Smith, Stephen W.; Winfree, William P.; Piascik, Robert S.

    2002-01-01

    During pre-servicing of a space shuttle (orbiter vehicle, OV-102), helium leak detection of an avionics cold plate identified a leak located in the face sheet oriented towards the support shelf. Subsequent destructive examination of the leaking cold plate revealed that intergranular corrosion had penetrated the 0.017-inch thick aluminum (AA6061) face sheet. The intergranular attack (IGA) was likely caused by an aggressive crevice environment created by condensation of water vapor between the cold plate and support shelf. Face sheet susceptibility to IGA is a result of the brazing process used in the fabrication of the cold plates. Cold plate components were brazed at 1000 F followed by a slow cooling process to avoid distortion of the bonded cold plate. The slow cool process caused excessive grain boundary precipitation resulting in a material that is susceptible to IGA. The objectives of this work are as follows: (1) Develop first-of-a-kind nondestructive evaluation (NDE) standards that contain IGA identical to that found in the orbiter cold plates; and (2) Assess advanced NDE techniques for corrosion detection and recommend methods for cold plate examination. This report documents the results of work performed at Langley Research Center to fulfill these objectives.

  2. Simple screening method for gram-positive bacterial beta-lactam antibiotic tolerance on routine laboratory Bauer-Kirby antibiogram plates.

    PubMed

    Traub, W H

    1982-01-01

    A simple screening method served to detect beta-lactam antibiotic-tolerant variants of clinical isolates and laboratory control strains of staphylococcus aureus, S. epidermis, group B beta-hemolytic streptococci, and Listeria monocytogenes. The beta-lactamase(s) of a multiple drug-resistant strain of Enterobacter cloacae (isolate No. 19) yielded most consistent results as compared with several other beta-lactamase producers; the E. cloacae beta-lactamase(s) was neutralized by clavulanic acid. Spot inocula of E. cloacae isolate No. 19, following overnight "induction" with 1 microgram/ml of ampicillin and 3 microgram/ml of cephalothin in tryptic soya broth, were applied centrally to beta-lactam antibiotic inhibition zones of Bauer-Kirby antibiogram plates (Mueller-Hinton agar, MHA, and diagnostic sensitivity test agar, DSTA) following removal of the appropriate disks. The spot-inoculated plates were incubated overnight at 35 degrees C and inspected for satellite growths of tolerant variants around the E. cloacae spot inocula. Satellite growths of less than or equal to 10 colonies were interpreted to indicate tolerance of the relevant cell wall synthesis inhibitor. The method readily permitted detection of variants tolerant for ampicillin, cephalothin, penicillin G, piperacillin, azlocillin, and mezlocillin. However, strains documented by minimal inhibitory and minimal bactericidal concentrations to be tolerant for cefotaxime, cefoxitin, fosfomycin, and vancomycin only rarely gave rise to respective satellite growths. DSTA proved superior to MHA with respect to "rescue" of inhibited tolerant staphylococcal variants; furthermore, the diameters of inhibition zones obtained on DSTA correlated well with those on MHA. Therefore, DSTA was adopted as the routine test medium for clinical staphylococcal isolates.

  3. A comparison of antibiotic disks from different sources on Quicolor and Mueller-Hinton agar media in evaluation of antibacterial susceptibility testing

    PubMed Central

    Saffari, Neda; Salmanzadeh-Ahrabi, Siavosh; Abdi-Ali, Ahya; Rezaei-Hemami, Mohsen

    2016-01-01

    Background and Objectives: Antibacterial susceptibility testing of clinical bacterial isolates through disk diffusion method plays a major role in antibacterial treatment. One of the main factors affecting the result of these tests is the type, structure and quality of the disks. The main objective of this study was to compare the agreement of antibiotic disks originated from three companies on Quicolor and Mueller-Hinton agar. Materials and Methods: Quicolor and Mueller-Hinton agar media were used in disk diffusion method. Seventy clinical isolates from Enterobacteriaceae family (21 Klebsiella spp., 36 Escherichia coli, 1 Enterobacter spp. and 12 Shigella spp.) were investigated in the study. After obtaining data, the results were interpreted as resistant, sensitive or intermediate. Kappa coefficient measured the agreement of two media. Coefficient of variation (CV) was also calculated for antibiotic disks. Results: The kappa agreement values for three types of antibiotic disks on Quicolor and Mueller-Hinton agar plates were good or excellent for all the examined antibiotics. CV values were also very satisfactory in the majority of cases. Conclusion: Antibiotic disks from three manufacturers can successfully be used on both Quicolor and Mueller-Hinton agar plates. PMID:28149489

  4. The Axisymmetric Analysis of Circular Plates Using the Radial Point Interpolation Method

    NASA Astrophysics Data System (ADS)

    Vasheghani Farahani, Behzad; Berardo, José Manuel; Drgas, Rafal; César de Sá, José M. A.; Ferreira, António J. M.; Belinha, Jorge

    2015-11-01

    This work extends the radial point interpolation method (RPIM) to the elasto-static analysis of circular plates. Instead using a plate bending theory, the 2D axisymmetric deformation theory is assumed. The RPIM enforces the nodal connectivity with the influence-domain concept and integrates numerically the integro-differential equations governing the studied phenomenon using a background integration mesh. Thus, both concepts are revised and more adequate parameters are found for the axisymmetric RPIM approach. Several benchmark circular plate examples are solved and the results are compared with other numerical approaches, showing that the RPIM is capable to obtain accurate and smooth variable fields.

  5. Method and apparatus for actively controlling a micro-scale flexural plate wave device

    DOEpatents

    Dohner, Jeffrey L.

    2001-01-01

    An actively controlled flexural plate wave device provides a micro-scale pump. A method of actively controlling a flexural plate wave device produces traveling waves in the device by coordinating the interaction of a magnetic field with actively controlled currents. An actively-controlled flexural plate wave device can be placed in a fluid channel and adapted for use as a micro-scale fluid pump to cool or drive micro-scale systems, for example, micro-chips, micro-electrical-mechanical devices, micro-fluid circuits, or micro-scale chemical analysis devices.

  6. New methods for isolation of keratolytic bacteria inducing intractable hoof wall cavity (Gidoh) in a horse; double screening procedures of the horn powder agar-translucency test and horn zymography

    PubMed Central

    KUWANO, Atsutoshi; NIWA, Hidekazu; ARAI, Katsuhiko

    2017-01-01

    ABSTRACT To establish a new system to isolate keratolytic bacteria from the hoof wall cavity (Gidoh) of a racehorse, we invented the horn powder agar-translucency (HoPAT) test and horn zymography (HZ). Using routine bacteriological techniques and these methods, we isolated five strains of keratolytic soil bacteria, which were then identified by means of 16S ribosomal RNA (rRNA) gene sequencing analysis. The findings from the study on the horse suggested that Brevibacterium luteolum played the main role in the local fragility of the hoof, eventually forming a Gidoh in coordination with four other strains of keratolytic bacteria. The double screening procedures of the HoPAT test and HZ were useful and easy techniques for isolating the keratolytic bacteria from the horn lesions.

  7. Replica plating method for estimating phenanthrene-utilizing and phenanthrene-cometabolizing microorganisms

    SciTech Connect

    Shiaris, M.P.; Cooney, J.J.

    1983-02-01

    A replica plating method was developed for detecting and enumerating phenanthrene-degrading microorganisms. The method is designed to discriminate between aquatic organisms that utilize phenanthrene as the sole carbon and energy source and organisms that cometabolize phenanthrene. The method was used to demonstrate that phenanthrene utilizers and phenanthrene cometabolizers coexist in estuarine sediments.

  8. Electrochemical Device Comprising Composite Bipolar Plate and Method of Using the Same

    NASA Technical Reports Server (NTRS)

    Mittelsteadt, Cortney K. (Inventor); Braff, William A. (Inventor)

    2013-01-01

    An electrochemical device and methods of using the same. In one embodiment, the electrochemical device may be used as a fuel cell and/or as an electrolyzer and includes a membrane electrode assembly (MEA), an anodic gas diffusion medium in contact with the anode of the MEA, a cathodic gas diffusion medium in contact with the cathode, a first bipolar plate in contact with the anodic gas diffusion medium, and a second bipolar plate in contact with the cathodic gas diffusion medium. Each of the bipolar plates includes an electrically-conductive, chemically-inert, non-porous, liquid-permeable, substantially gas-impermeable membrane in contact with its respective gas diffusion medium, as well as a fluid chamber and a non-porous an electrically-conductive plate.

  9. Electrochemical Device Comprising Composite Bipolar Plate and Method of Using the Same

    NASA Technical Reports Server (NTRS)

    Mittelsteadt, Cortney K. (Inventor); Braff, William A. (Inventor)

    2017-01-01

    An electrochemical device and methods of using the same. In one embodiment, the electrochemical device may be used as a fuel cell and/or as an electrolyzer and includes a membrane electrode assembly (MEA), an anodic gas diffusion medium in contact with the anode of the MEA, a cathodic gas diffusion medium in contact with the cathode, a first bipolar plate in contact with the anodic gas diffusion medium, and a second bipolar plate in contact with the cathodic gas diffusion medium. Each of the bipolar plates includes an electrically-conductive, chemically-inert, non-porous, liquid-permeable, substantially gas-impermeable membrane in contact with its respective gas diffusion medium, as well as a fluid chamber and a non-porous an electrically-conductive plate.

  10. Approximate natural vibration analysis of rectangular plates with openings using assumed mode method

    NASA Astrophysics Data System (ADS)

    Cho, Dae Seung; Vladimir, Nikola; Choi, Tae MuK

    2013-09-01

    Natural vibration analysis of plates with openings of different shape represents an important issue in naval architecture and ocean engineering applications. In this paper, a procedure for vibration analysis of plates with openings and arbitrary edge constraints is presented. It is based on the assumed mode method, where natural frequencies and modes are determined by solving an eigenvalue problem of a multi-degree-of-freedom system matrix equation derived by using Lagrange's equations of motion. The presented solution represents an extension of a procedure for natural vibration analysis of rectangular plates without openings, which has been recently presented in the literature. The effect of an opening is taken into account in an intuitive way, i.e. by subtracting its energy from the total plate energy without opening. Illustrative numerical examples include dynamic analysis of rectangular plates with rectangular, elliptic, circular as well as oval openings with various plate thicknesses and different combinations of boundary conditions. The results are compared with those obtained by the finite element method (FEM) as well as those available in the relevant literature, and very good agreement is achieved.

  11. High Velocity Tensile Test for Thin Plate Specimen with One Bar Method

    NASA Astrophysics Data System (ADS)

    Itabashi, Masaaki

    In order to design thin-walled impact-resistant structure, for example, an automotive body, dynamic behavior of thin plate is essential. So far, except for laminated composite materials, high velocity tensile test of thin plate specimen did not attract impact researchers' and engineers' attention very much. In this paper, the previous thin plate specimen assembly for the one bar method was improved. The one bar method has been utilized for cylindrical specimens of various solid materials and is known as an effective high velocity tensile testing technique. Unfortunately, the previous assembly introduced a tremendous initial peak on stress-strain curves, even for aluminum alloys. With a new specimen assembly, stress-strain curves for IF (Interstitial-atom Free) steel and 7075-T6 aluminum alloy obtained by the one bar method were almost equivalent to those obtained by the tensile version of the split Hopkinson pressure bar method.

  12. The simulation of Lamb waves in a cracked plate using the scaled boundary finite element method.

    PubMed

    Gravenkamp, Hauke; Prager, Jens; Saputra, Albert A; Song, Chongmin

    2012-09-01

    The scaled boundary finite element method is applied to the simulation of Lamb waves for ultrasonic testing applications. With this method, the general elastodynamic problem is solved, while only the boundary of the domain under consideration has to be discretized. The reflection of the fundamental Lamb wave modes from cracks of different geometry in a steel plate is modeled. A test problem is compared with commercial finite element software, showing the efficiency and convergence of the scaled boundary finite element method. A special formulation of this method is utilized to calculate dispersion relations for plate structures. For the discretization of the boundary, higher-order elements are employed to improve the efficiency of the simulations. The simplicity of mesh generation of a cracked plate for a scaled boundary finite element analysis is illustrated.

  13. Development of target allocation methods for LAMOST focal plate

    NASA Astrophysics Data System (ADS)

    Yuan, Hailong; Zhang, Haotong; Zhang, Yanxia; Lei, Yajuan; Dong, Yiqiao

    2014-01-01

    We first introduce the primary target allocation requirements and restrictions for the parallel control multiple fiber system, which is used in the LAMOST spectroscopic survey. The fiber positioner anti-collision model is imported. Then several target allocation methods and features are discussed in detail, including a network flow algorithm, high priority for fiber unit holding less target number, target allocation algorithm for groups, target allocation method for add-ons and target reallocation. Their virtues and weaknesses are analyzed for various kinds of scientific research situations. Furthermore an optimization concept using the Simulate Anneal Arithmetic (SAA) is developed to improve the fiber utilizing efficiency.

  14. Verification of 235U mass content in nuclear fuel plates by an absolute method

    NASA Astrophysics Data System (ADS)

    El-Gammal, W.

    2007-01-01

    Nuclear Safeguards is referred to a verification System by which a State can control all nuclear materials (NM) and nuclear activities under its authority. An effective and efficient Safeguards System must include a system of measurements with capabilities sufficient to verify such NM. Measurements of NM using absolute methods could eliminate the dependency on NM Standards, which are necessary for other relative or semi-absolute methods. In this work, an absolute method has been investigated to verify the 235U mass content in nuclear fuel plates of Material Testing Reactor (MTR) type. The most intense gamma-ray signature at 185.7 keV emitted after α-decay of the 235U nuclei was employed in the method. The measuring system (an HPGe-spectrometer) was mathematically calibrated for efficiency using the general Monte Carlo transport code MCNP-4B. The calibration results and the measured net count rate were used to estimate the 235U mass content in fuel plates at different detector-to-fuel plate distances. Two sets of fuel plates, containing natural and low enriched uranium, were measured at the Fuel Fabrication Facility. Average accuracies for the estimated 235U masses of about 2.62% and 0.3% are obtained for the fuel plates containing natural and low enriched uranium; respectively, with a precision of about 3%.

  15. C1-continuous Virtual Element Method for Poisson-Kirchhoff plate problem

    SciTech Connect

    Gyrya, Vitaliy; Mourad, Hashem Mohamed

    2016-09-20

    We present a family of C1-continuous high-order Virtual Element Methods for Poisson-Kirchho plate bending problem. The convergence of the methods is tested on a variety of meshes including rectangular, quadrilateral, and meshes obtained by edge removal (i.e. highly irregular meshes). The convergence rates are presented for all of these tests.

  16. Phase Velocity Method for Guided Wave Measurements in Composite Plates

    NASA Astrophysics Data System (ADS)

    Moreno, E.; Galarza, N.; Rubio, B.; Otero, J. A.

    Carbon Fiber Reinforced Polymer is a well-recognized material for aeronautic applications. Its plane structure has been widely used where anisotropic characteristics should be evaluated with flaw detection. A phase velocity method of ultrasonic guided waves based on a pitch-catch configuration is presented for this purpose. Both shear vertical (SV) and shear horizontal (SH) have been studied. For SV (Lamb waves) the measurements were done at different frequencies in order to evaluate the geometrical dispersion and elastic constants. The results for SV are discussed with an orthotropic elastic model. Finally experiments with lamination flaws are presented.

  17. 3-D vibration analysis of annular sector plates using the Chebyshev-Ritz method

    NASA Astrophysics Data System (ADS)

    Zhou, D.; Lo, S. H.; Cheung, Y. K.

    2009-02-01

    The three-dimensional free vibration of annular sector plates with various boundary conditions is studied by means of the Chebyshev-Ritz method. The analysis is based on the three-dimensional small strain linear elasticity theory. The product of Chebyshev polynomials satisfying the necessary boundary conditions is selected as admissible functions in such a way that the governing eigenvalue equation can be conveniently derived through an optimization process by the Ritz method. The boundary functions guarantee the satisfaction of the geometric boundary conditions of the plates and the Chebyshev polynomials provide the robustness for numerical calculation. The present study provides a full vibration spectrum for the thick annular sector plates, which cannot be given by the two-dimensional (2-D) theories such as the Mindlin theory. Comprehensive numerical results with high accuracy are systematically produced, which can be used as benchmark to evaluate other numerical methods. The effect of radius ratio, thickness ratio and sector angle on natural frequencies of the plates with a sector angle from 120° to 360° is discussed in detail. The three-dimensional vibration solutions for plates with a re-entrant sector angle (larger than 180°) and shallow helicoidal shells (sector angle larger than 360°) with a small helix angle are presented for the first time.

  18. The complex variable reproducing kernel particle method for the analysis of Kirchhoff plates

    NASA Astrophysics Data System (ADS)

    Chen, L.; Cheng, Y. M.; Ma, H. P.

    2015-03-01

    In this paper, the complex variable reproducing kernel particle method (CVRKPM) for the bending problem of arbitrary Kirchhoff plates is presented. The advantage of the CVRKPM is that the shape function of a two-dimensional problem is obtained one-dimensional basis function. The CVRKPM is used to form the approximation function of the deflection of a Kirchhoff plate, the Galerkin weak form of the bending problem of Kirchhoff plates is adopted to obtain the discretized system equations, and the penalty method is employed to enforce the essential boundary conditions, then the corresponding formulae of the CVRKPM for the bending problem of Kirchhoff plates are presented in detail. Several numerical examples of Kirchhoff plates with different geometry and loads are given to demonstrate that the CVRKPM in this paper has higher computational precision and efficiency than the reproducing kernel particle method under the same node distribution. And the influences of the basis function, weight function, scaling factor, node distribution and penalty factor on the computational precision of the CVRKPM in this paper are discussed.

  19. [Comparison of methods for the quantitative detection of moulds in foods. II. Communication: effect of homogenisation conditions on mould plate count (author's transl)].

    PubMed

    Blaser, P

    1978-05-01

    The different effects of homogenisation of four commonly used homogenisating apparatus, such as Stomacher, Ultraturrax, Waring-Blender, Bühler-homogenisator) were compared with each other by applying 1 artificially and 6 naturally moulded, non-fluid food products. Furthermore the influence of sedimentation in the homogenisate as well as the time of homogenisation was examined. One part of the examination was the direct microscopic observation on stained Breed-smears, the other part the cultural methods (number of mould plate count on malt extract agar). The homogenisation effect of the Stomacher was as good as with all other mentioned apparatus with the food products applied, except for the home-made smoked sausage. With this home made smoked sausage, much better results were obtained by these homogenisating apparatus, especially by the Bühler Homogenisator. This is due to the fact that the sausage was minced to a much higher degree and thus the inner mould flora was set free.--A more tender effect of the Stomacher on hyphal elements could not be achieved.--Prolonging the time of homogenisation from 1 minute to 2 up to 4 minutes did not give any better results.--A short sedimentation of coarser food particles facilitates the pipetting of the homogenisates without influencing the mould counts.--The naturally moulded foods, which were kept at room temperature for several weeks, showed a significantly smaller number of plate count than of total mould count in contrary to those foods moulded just before experimental beginning.

  20. An extended field method solution for a pulse loaded thin plate

    NASA Technical Reports Server (NTRS)

    Donaldson, B. K.; Starkey, N. B.

    1980-01-01

    This paper deals with a new extension of a weighted residual method of analysis called the extended field method. The extended field method is applied for the first time to the problem of the transient vibration of a uniformly thin elastic plate. Numerical results have been obtained which validate the analysis procedure and show better solution convergence than is obtainable by standard methods of analysis for the same number of degrees of freedom. Further studies are necessary to obtain still better convergence.

  1. The Interpretation of Dynamic Contact Angles Measured by the Wilhelmy Plate Method

    PubMed

    Ramé

    1997-01-01

    We present an analysis for properly interpreting apparent dynamic contact angles measured using the Wilhelmy plate method at low capillary numbers, Ca. This analysis removes the ambiguity in current dynamic measurements which interpret data with the same formula as static measurements. We properly account for all forces, including viscous forces, acting on the plate as it moves into or out of a liquid bath. Our main result, valid at O(1) as Ca --> 0, relates the apparent dynamic contact angle to material-dependent, geometry-independent parameters necessary for describing dynamic wetting of a system. The special case of the apparent contact angle = pi/2 was solved to O(Ca). This O(Ca) solution can guide numerical work necessary for higher Ca's and arbitrary values of the apparent contact angle. These results make the Wilhelmy plate a viable method for determining material parameters for dynamic spreading.

  2. A variable-order laminated plate theory based on the variational-asymptotical method

    NASA Technical Reports Server (NTRS)

    Lee, Bok W.; Sutyrin, Vladislav G.; Hodges, Dewey H.

    1993-01-01

    The variational-asymptotical method is a mathematical technique by which the three-dimensional analysis of laminated plate deformation can be split into a linear, one-dimensional, through-the-thickness analysis and a nonlinear, two-dimensional, plate analysis. The elastic constants used in the plate analysis are obtained from the through-the-thickness analysis, along with approximate, closed-form three-dimensional distributions of displacement, strain, and stress. In this paper, a theory based on this technique is developed which is capable of approximating three-dimensional elasticity to any accuracy desired. The asymptotical method allows for the approximation of the through-the-thickness behavior in terms of the eigenfunctions of a certain Sturm-Liouville problem associated with the thickness coordinate. These eigenfunctions contain all the necessary information about the nonhomogeneities along the thickness coordinate of the plate and thus possess the appropriate discontinuities in the derivatives of displacement. The theory is presented in this paper along with numerical results for the eigenfunctions of various laminated plates.

  3. Validating the plate mapping method: Comparing drawn foods and actual foods of university students in a cafeteria.

    PubMed

    Sharp, David E

    2016-05-01

    To examine effects of plate size on meals, I developed a method I label plate mapping. To validate plate mapping, a quasi-experimental between participants study was conducted that asked university students to accurately draw their lunch meal. Participants were randomized into groups where they were asked either pre-consumption or post-consumption to draw their lunch on either a 9″ or 11″ paper plate. Coding plate drawings for total meal size revealed that students drew bigger meals on larger plates and participant meal size drawings were more accurate when the plate provided was the same size as the meal plate used. Gender moderated meal size drawings, with women generally drawing meals that were more highly correlated and similarly sized to actual meals when compared to the drawings of men. Overall, the size of plate drawings was highly correlated with the size of actual foods, which provides support for the validity of the method of plate mapping. These findings suggest that plate mapping can be applied to estimate meal size and assess sensitivity to plate size. Gaining a better understanding of the mechanisms and processes that influence food consumption habits can help increase awareness of these cues for both academics as well as for consumers of food and benefit short- and long-term health goals.

  4. The physicochemical property characterization of agar acetate.

    PubMed

    Xia, Kai; Liu, Xin; Zhao, Jingkun; Zhang, Xiaodong

    2014-09-22

    A series of agar acetates with different degree of substitution (DS) were prepared, and their properties were determined and analyzed. The results showed that the gelling temperature, the gel melting temperature, the gel strength, the gel hardness, the gel fracturability, the gel springiness and the solution apparent viscosity of agar acetates all decreased except that their gel cohesiveness increased with the increase of DS. The variation process of agar molecules in solution from coil to helix could be also observed by measuring solution optical rotation in a lower concentration at which even the solution could not form a gel. The gel skeleton structures of agar acetates were of porous network structures, and the pores became smaller and denser with the increase of DS. After acetylation, the water holding capacity of the agar was improved, but its thermal stability was lowered.

  5. Biochemical differentiation of the Enterobacteriaceae with the aid of lysine-iron-agar.

    PubMed

    Johnson, J G; Kunz, L J; Barron, W; Ewing, W H

    1966-03-01

    A procedure is described for identifying members of the family Enterobacteriaceae isolated from clinical specimens. The methods are based on primary differentiation of the various groups of bacteria by the use of Kligler Iron Agar and lysine-iron-agar. For identification of Salmonella, Shigella, and Arizona group organisms from stools, Triple Sugar Iron Agar and lysine-iron-agar are employed. The usefulness of this schema for diagnostic bacteriology laboratories is discussed. It is not intended to replace methods used in reference or research laboratories.

  6. The boundary element method in stress-state problems for an ansiotropic plate with holes

    SciTech Connect

    Neskorodev, N.M.

    1995-12-25

    We propose a method of solving the problem of the stress state of an anisotropic plate with holes of arbitrary shape. The method is based on approximating the boundary of a region by curved boundary elements. These elements are taken to be a family of semi-ellipses. To satisfy the boundary conditions we use the pointwise least-square method. Numerical experiments showed good agreement of the computations with results known earlier.

  7. A novel acoustic emission beamforming method with two uniform linear arrays on plate-like structures.

    PubMed

    Xiao, Denghong; He, Tian; Pan, Qiang; Liu, Xiandong; Wang, Jin; Shan, Yingchun

    2014-02-01

    A novel acoustic emission (AE) source localization approach based on beamforming with two uniform linear arrays is proposed, which can localize acoustic sources without accurate velocity, and is particularly suited for plate-like structures. Two uniform line arrays are distributed in the x-axis direction and y-axis direction. The accurate x and y coordinates of AE source are determined by the two arrays respectively. To verify the location accuracy and effectiveness of the proposed approach, the simulation of AE wave propagation in a steel plate based on the finite element method and the pencil-lead-broken experiment are conducted, and the AE signals obtained from the simulations and experiments are analyzed using the proposed method. Moreover, to study the ability of the proposed method more comprehensive, a plate of carbon fiber reinforced plastics is taken for the pencil-lead-broken test, and the AE source localization is also realized. The results indicate that the two uniform linear arrays can localize different sources accurately in two directions even though the localizing velocity is deviated from the real velocity, which demonstrates the effectiveness of the proposed method in AE source localization for plate-like structures.

  8. Method for preparing surfaces of metal composites having a brittle phase for plating. [Patent application

    DOEpatents

    Coates, C.W.; Wilson, T.J.

    1982-05-19

    The present invention is directed to a method for preparing surfaces of two-phase metal composites having relatively brittle and malleable components for plating with corrosion-resistant material. In practice of the present invention, the surfaces of the composite are etched to remove a major portion or fraction of the brittle component. The etched surface is then peened with particulates for breaking the brittle component from the surfaces and for spreading or smearing the malleable component over the surfaces. The peened surface is then chemically cleaned of residual traces of the brittle component to which the corrosion-resistant material may be plated thereon in an adherent manner.

  9. Characterization of nano-sized SiC@Ni composite fabricated by electroless plating method.

    PubMed

    Xu, Zhan; Chen, Yigang

    2013-02-01

    A nano-sized SiC@Ni composite was prepared by simple electroless plating method. Nickel can be reduced by Na2H2PO2 under the catalysis of Pd to despite onto the surface of SiC nanoparticles. The composite structure was characterized by means of TEM images, XRD and the components were analyzed using EDS. The coating layer on the SiC particles was several nanometers thick and mainly in a form of fine Ni crystalline grain and amorphous Ni-P alloy. By increasing the concentration of Na2H2PO2 in the plating bath, the uniformity of the coating layer can be improved obviously. Both of the magnetism and crystallinity of Ni coatings depends on the P content in the coating which can be decreased by increasing the pH values of plating solutions. The SiC@Ni particles exhibited soft magnetic characteristics.

  10. An automatic system for measurement of retardation of wave plates based on phase-shifted method

    NASA Astrophysics Data System (ADS)

    Gao, Zhishan; Yan, Ming

    2005-02-01

    A practical system is described to measure the retardation of wave plates with phase-shifted method. The tested wave plate is put in and the original angle between the axis of it and the analyzer is random, not 45 degree. For the measurement is made rapidly and automatically, a standard wave plate act as a compensator, the stepping motor is used to drive the analyzer to realize phase shifting and a grating encoder is used to measure its rotating angle. At the same time, while the beam comes out from the analyzer, the photoelectric detector gets its intensity, and then the signals is magnified, filtered and sent to computer through its serial port. The results show the system has the advantages of costing little time and high accuracy.

  11. NAS agar is more suitable than McKay agar for primary culture of Streptococcus milleri group (SMG) fastidious bacteria, S. intermedius in particular.

    PubMed

    Raclavsky, Vladislav; Novotny, Radko; Stary, Lubomir; Navratilova, Lucie; Zatloukal, Jaromir; Jakubec, Petr; Zapalka, Martin; Kopriva, Frantisek; Kolek, Vitezslav

    2017-01-01

    Streptococcus milleri group (SMG) is a group of three streptococcal species (S. anginosus, intermedius and constellatus) that act as opportunist pathogens, among others in cystic fibrosis. Due to their fastidious character, they are both difficult to cultivate and to differentiate from less pathogenic streptococcal species, therefore being most probably underdiagnosed. Semi-selective McKay agar and NAS agar were developed to facilitate SMG recovery from clinical samples; however, direct comparison of recovery rates has not been published yet. We tested the performance of both media on 123 patient samples and demonstrated general superiority of NAS agar for SMG recovery during primary cultivation convincingly. This observation was also confirmed by quantitative drop tests during subculture. Despite the undisputed overall superiority of NAS agar over McKay agar, a smaller fraction of strains grew better on McKay agar. Inter-strain differences were the most probable explanation. Therefore, when economic conditions are not limiting and maximum recovery rate is desirable, both plates are advised to be used in parallel for primary cultivation of clinical samples.

  12. The vibration and stability analysis of moderate thick plates by the method of lines

    NASA Astrophysics Data System (ADS)

    Tang, Shou-Gao; Yuan, Si

    1992-06-01

    The method of lines based on Hu Hai-chang's theory for the vibration and stability of moderate thick plates is developed. The standard nonlinear ordinary differential equation (ODE) system for natural frequencies and critical load is given by use of ODE techniques; any indicated eigenvalue could be obtained directly from ODE solver by employing the so-called initial eigenfunction technique instead of the mode orthogonality condition. Numerical examples show that the present method is very effective and reliable.

  13. The Method of Eichhorn with Non-Standard Projections for a Single Plate

    NASA Astrophysics Data System (ADS)

    Cardona, O.; Corona-Galindo, M.

    1990-11-01

    RESUMEN. Se desarrollan las expresiones para el metodo de Eichhorn en astrometria para proyecciones diferentes a la estandar. El se usa para obtener las coordenadas esfericas de estrellas en placas astron6micas cuando las variables contienen errores. ABSTRACT. We develop the expressions for the Eichhorn's Method in astrometry for non-standard projections. The method is used to obtain spherical coordinates of stars in astronomical plates, when all the variables have errors. Key words: ASTROMETRY

  14. Buckling analysis of moderately thick rectangular plates using coupled displacement field method

    NASA Astrophysics Data System (ADS)

    Meera Saheb, K.; Aruna, K.

    2015-12-01

    A simple and efficient coupled displacement field method is developed to study the buckling load parameters of the moderately thick rectangular plates. This method has been successfully applied to study the same for the Timoshenko beams. A single term trigonometric admissible displacement field is assumed for one of the variables, say, the total rotations (in both X, Y directions). Making use of the coupling equations, the spatial variation for the remaining lateral displacement field is derived in terms of the total rotations. The coupled displacement field method makes the energy formulation to contains half the number of unknown independent coefficients, in the case of a rectangular plate, contrary to the conventional Rayleigh-Ritz method. The expressions for the non-dimensional buckling load parameters of the moderately thick rectangular plates with all the edges simply supported are derived. The numerical values of these parameters obtained using the coupled displacement field method match very well with open literature demonstrating the effectiveness of the coupled displacement field method.

  15. A passive guard for low thermal conductivity measurement of small samples by the hot plate method

    NASA Astrophysics Data System (ADS)

    Jannot, Yves; Degiovanni, Alain; Grigorova-Moutiers, Veneta; Godefroy, Justine

    2017-01-01

    Hot plate methods under steady state conditions are based on a 1D model to estimate the thermal conductivity, using measurements of the temperatures T 0 and T 1 of the two sides of the sample and of the heat flux crossing it. To be consistent with the hypothesis of the 1D heat flux, either a hot plate guarded apparatus is used, or the temperature is measured at the centre of the sample. On one hand the latter method can be used only if the ratio thickness/width of the sample is sufficiently low and on the other hand the guarded hot plate method requires large width samples (typical cross section of 0.6  ×  0.6 m2). That is why both methods cannot be used for low width samples. The method presented in this paper is based on an optimal choice of the temperatures T 0 and T 1 compared to the ambient temperature T a, enabling the estimation of the thermal conductivity with a centered hot plate method, by applying the 1D heat flux model. It will be shown that these optimal values do not depend on the size or on the thermal conductivity of samples (in the range 0.015-0.2 W m-1 K-1), but only on T a. The experimental results obtained validate the method for several reference samples for values of the ratio thickness/width up to 0.3, thus enabling the measurement of the thermal conductivity of samples having a small cross-section, down to 0.045  ×  0.045 m2.

  16. Mechanical touch responses of Arabidopsis TCH1-3 mutant roots on inclined hard-agar surface

    NASA Astrophysics Data System (ADS)

    Zha, Guodong; Wang, Bochu; Liu, Junyu; Yan, Jie; Zhu, Liqing; Yang, Xingyan

    2016-01-01

    The gravity-induced mechanical touch stimulus can affect plant root architecture. Mechanical touch responses of plant roots are an important aspect of plant root growth and development. Previous studies have reported that Arabidopsis TCH1-3 genes are involved in mechano-related events, how-ever, the physiological functions of TCH1-3 genes in Arabidopsis root mechanoresponses remain unclear. In the present study, we applied an inclined hard agar plate method to produce mechanical touch stimulus, and provided evidence that altered mechanical environment could influence root growth. Furthermore, tch1-3 Arabidopsis mutants were investigated on inclined agar surfaces to explore the functions of TCH1-3 genes on Arabidopsis root mechanoresponses. The results showed that two tch2 mutants, cml24-2 and cml24-4, exhibited significantly reduced root length, biased skewing, and decreased density of lateral root. In addition, primary root length and density of lateral root of tch3 (cml12-2) was significantly decreased on inclined agar surfaces. This study indicates that the tch2 and tch3 mutants are hypersensitive to mechanical touch stimulus, and TCH2 (CML24-2 and CML24-4) and TCH3 (CML12-2) genes may participate in the mechanical touch response of Arabidopsis roots.

  17. An interlaboratory study on efficient detection of Shiga toxin-producing Escherichia coli O26, O103, O111, O121, O145, and O157 in food using real-time PCR assay and chromogenic agar.

    PubMed

    Hara-Kudo, Yukiko; Konishi, Noriko; Ohtsuka, Kayoko; Iwabuchi, Kaori; Kikuchi, Rie; Isobe, Junko; Yamazaki, Takumiko; Suzuki, Fumie; Nagai, Yuhki; Yamada, Hiroko; Tanouchi, Atsuko; Mori, Tetsuya; Nakagawa, Hiroshi; Ueda, Yasufumi; Terajima, Jun

    2016-08-02

    To establish an efficient detection method for Shiga toxin (Stx)-producing Escherichia coli (STEC) O26, O103, O111, O121, O145, and O157 in food, an interlaboratory study using all the serogroups of detection targets was firstly conducted. We employed a series of tests including enrichment, real-time PCR assays, and concentration by immunomagnetic separation, followed by plating onto selective agar media (IMS-plating methods). This study was particularly focused on the efficiencies of real-time PCR assays in detecting stx and O-antigen genes of the six serogroups and of IMS-plating methods onto selective agar media including chromogenic agar. Ground beef and radish sprouts samples were inoculated with the six STEC serogroups either at 4-6CFU/25g (low levels) or at 22-29CFU/25g (high levels). The sensitivity of stx detection in ground beef at both levels of inoculation with all six STEC serogroups was 100%. The sensitivity of stx detection was also 100% in radish sprouts at high levels of inoculation with all six STEC serogroups, and 66.7%-91.7% at low levels of inoculation. The sensitivity of detection of O-antigen genes was 100% in both ground beef and radish sprouts at high inoculation levels, while at low inoculation levels, it was 95.8%-100% in ground beef and 66.7%-91.7% in radish sprouts. The sensitivity of detection with IMS-plating was either the same or lower than those of the real-time PCR assays targeting stx and O-antigen genes. The relationship between the results of IMS-plating methods and Ct values of real-time PCR assays were firstly analyzed in detail. Ct values in most samples that tested negative in the IMS-plating method were higher than the maximum Ct values in samples that tested positive in the IMS-plating method. This study indicates that all six STEC serogroups in food contaminated with more than 29CFU/25g were detected by real-time PCR assays targeting stx and O-antigen genes and IMS-plating onto selective agar media. Therefore, screening

  18. Method and apparatus for acoustic plate mode liquid-solid phase transition detection

    DOEpatents

    Blair, Dianna S.; Freye, Gregory C.; Hughes, Robert C.; Martin, Stephen J.; Ricco, Antonio J.

    1993-01-01

    A method and apparatus for sensing a liquid-solid phase transition event is provided which comprises an acoustic plate mode detecting element placed in contact with a liquid or solid material which generates a high-frequency acoustic wave that is attenuated to an extent based on the physical state of the material is contact with the detecting element. The attenuation caused by the material in contact with the acoustic plate mode detecting element is used to determine the physical state of the material being detected. The method and device are particularly suited for detecting conditions such as the icing and deicing of wings of an aircraft. In another aspect of the present invention, a method is provided wherein the adhesion of a solid material to the detecting element can be measured using the apparatus of the invention.

  19. An Accurate Method for Free Vibration Analysis of Structures with Application to Plates

    NASA Astrophysics Data System (ADS)

    KEVORKIAN, S.; PASCAL, M.

    2001-10-01

    In this work, the continuous element method which has been used as an alternative to the finite element method of vibration analysis of frames is applied to more general structures like 3-D continuum and rectangular plates. The method is based on the concept of the so-called impedance matrix giving in the frequency domain, the linear relation between the generalized displacements of the boundaries and the generalized forces exerted on these boundaries. For a 3-D continuum, the concept of impedance matrix is introduced assuming a particular kind of boundary conditions. For rectangular plates, this new development leads to the solution of vibration problems for boundary conditions other than the simply supported ones.

  20. Method and apparatus for acoustic plate mode liquid-solid phase transition detection

    NASA Astrophysics Data System (ADS)

    Blair, D. S.; Frye, G. C.; Hughes, R. C.; Martin, S. J.; Ricco, A. J.

    1990-05-01

    A method and apparatus for sensing a liquid-solid phase transition event is provided which comprises an acoustic plate mode detecting element placed in contact with a liquid or solid material which generates a high-frequency acoustic wave that is attenuated to an extent based on the physical state of the material in contact with the detecting element. The attenuation caused by the material in contact with the acoustic plate mode detecting element is used to determine the physical state of the material being detected. The method and device are particularly suited for detecting conditions such as the icing and deicing of wings of an aircraft. In another aspect of the present invention, a method is provided wherein the adhesion of a solid material to the detecting element can be measured using the apparatus of the invention.

  1. Some Experiments With Agar-Grown Seedlings

    ERIC Educational Resources Information Center

    Freeland, P. W.

    1973-01-01

    Two percent agar gel is reported as a better medium for germination and growth studies. Students can be encouraged to undertake many simple experiments and make precise observations by using this medium. (PS)

  2. Quenching of the antibacterial activity of chlorhexidine and benzalkonium by Letheen broth and Letheen agar in relation to wild-type and envelope mutant strains of gram-negative bacteria.

    PubMed

    el-Falaha, B M; Furr, J R; Russell, A D

    1987-01-01

    Letheen broth and Letheen agar have been investigated for their ability to act as neutralising and recovery media for wild-type and envelope mutants exposed to chlorhexidine diacetate and benzalkonium chloride. At high dilutions, untreated cells of the envelope mutant of Pseudomonas aeruginosa 799/61 were unable to produce colonies on Letheen agar. As a result of various procedures, it was concluded that dilution in Letheen broth and plating in Isosensitest agar was a suitable method for quenching cationic bactericides without harming the test strains, and that the increasing use of Gram-negative bacteria with outer membrane defects means that considerable care may be necessary in selecting media for evaluating bactericidal activity.

  3. Differentiation of Candida dubliniensis from Candida albicans on rosemary extract agar and oregano extract agar.

    PubMed

    de Loreto, Erico Silva; Pozzatti, Patrícia; Alves Scheid, Liliane; Santurio, Deise; Morais Santurio, Janio; Alves, Sydney Hartz

    2008-01-01

    Candida dubliniensis is a recently described pathogenic species which shares many phenotypic features with Candida albicans and therefore, may be misidentified in microbiological laboratories. Because molecular methods can be onerous and unfeasible in routine mycological laboratories with restricted budgets such as those in developing countries, phenotypic techniques have been encouraged in the development of differential media for the presumptive identification of these species. We examined the colony morphology and chlamydospore production of 30 C. dubliniensis isolates and 100 C. albicans isolates on two new proposed media: rosemary (Rosmarinus officinalis) extract agar (REA) and oregano (Origanum vulgare) extract agar (OEA). These substrates are traditionally used as spices and medicinal herbs. In both of these media, all C. dubliniensis isolates (100%) showed rough colonies with peripheral hyphal fringes and abundant chlamydospores after 24 to 48 hr of incubation at 25 degrees C. In contrast, under the same conditions, all isolates of C. albicans (100%) showed smooth colonies without hyphal fringes or chlamydospores. In conclusion, REA and OEA offer a simple, rapid, and inexpensive screening media for the differentiation of C. albicans and C. dubliniensis.

  4. Validation of a two-plate microbiological method for screening antibiotic residues in shrimp tissue.

    PubMed

    Dang, Pham Kim; Degand, Guy; Danyi, Sophie; Pierret, Gilles; Delahaut, Philippe; Ton, Vu Dinh; Maghuin-Rogister, Guy; Scippo, Marie-Louise

    2010-07-05

    Microbiological inhibition screening tests could play an important role to detect residues of antibiotics in the different animal food products, but very few are available for the aquaculture products in general, and for shrimps in particular. A two-plate microbiological method to screen shrimp for residues of the most commonly used antibiotics has been developed and validated according to criteria derived from the European Commission Decision 2002/657/CE. Bacillus subtilis was used as a sensitive strain to target antibiotics. Culture conditions on Petri plates (pH of medium) were selected to enhance the capacity of antibiotic detection. Antibiotic residues were extracted from shrimps using acetonitrile/acetone (70/30, v/v) before application on Petri plates seeded with B. subtilis. The method was validated using spiked blank tissues as well as antibiotic treated shrimps with enrofloxacin and tetracycline, two antibiotics often found to be used in shrimp production. For tetracyclines and (fluoro)quinolones, the detection capability was below the maximum residue limit (MRL), while it was around the MRL for sulfonamides. The specificity of the microbiological screening was 100% in all cases while the sensitivity and accuracy was 100% in almost all cases. The capacity of the method to detect contaminated samples was confirmed on antibiotic treated shrimps, analyzed in parallel with a confirmatory method (Liquid Chromatography coupled to mass spectrometry (LC-MS)).

  5. Crack Imaging and Quantification in Aluminum Plates with Guided Wave Wavenumber Analysis Methods

    NASA Technical Reports Server (NTRS)

    Yu, Lingyu; Tian, Zhenhua; Leckey, Cara A. C.

    2015-01-01

    Guided wavefield analysis methods for detection and quantification of crack damage in an aluminum plate are presented in this paper. New wavenumber components created by abrupt wave changes at the structural discontinuity are identified in the frequency-wavenumber spectra. It is shown that the new wavenumbers can be used to detect and characterize the crack dimensions. Two imaging based approaches, filter reconstructed imaging and spatial wavenumber imaging, are used to demonstrate how the cracks can be evaluated with wavenumber analysis. The filter reconstructed imaging is shown to be a rapid method to map the plate and any existing damage, but with less precision in estimating crack dimensions; while the spatial wavenumber imaging provides an intensity image of spatial wavenumber values with enhanced resolution of crack dimensions. These techniques are applied to simulated wavefield data, and the simulation based studies show that spatial wavenumber imaging method is able to distinguish cracks of different severities. Laboratory experimental validation is performed for a single crack case to confirm the methods' capabilities for imaging cracks in plates.

  6. Morphological development of Morchella conica mycelium on different agar media.

    PubMed

    Guler, P; Ozkaya, E G

    2009-07-01

    The present study presents the development of mycelium of Morchella conica where different concentration of sucrose added at different agar media. For this sucrose have been added as 0.25, 0.50, 0.75, 1.00 and 1.25% concentration to wheat agar potato dextrose agar malt extract agar and complete medium yeast agar The radial growth speed, morphologic specifications, radial growth radius and pigmentation of mycelium were taken as criteria, the development period of mycelium in wheat agar was completed in 4 days and mycelium were very thin. The colonization period of the mycelium was determined; 7 days in potato dextrose agar 5 days in malt extract agar and 5 days at complete medium yeast agar. The development of the mycelium; at potato dextrose agar was dense and circular; at malt extract agar and at completed medium yeast agar was rhizomorphic. Mycelium has developed very well at sucrose medium and formed creamy and light yellow pigmentation.

  7. Blind inversion method using Lamb waves for the complete elastic property characterization of anisotropic plates.

    PubMed

    Vishnuvardhan, J; Krishnamurthy, C V; Balasubramaniam, Krishnan

    2009-02-01

    A novel blind inversion method using Lamb wave S(0) and A(0) mode velocities is proposed for the complete determination of elastic moduli, material symmetries, as well as principal plane orientations of anisotropic plates. The approach takes advantage of genetic algorithm, introduces the notion of "statistically significant" elastic moduli, and utilizes their sensitivities to velocity data to reconstruct the elastic moduli. The unknown material symmetry and the principal planes are then evaluated using the method proposed by Cowin and Mehrabadi [Q. J. Mech. Appl. Math. 40, 451-476 (1987)]. The blind inversion procedure was verified using simulated ultrasonic velocity data sets on materials with transversely isotropic, orthotropic, and monoclinic symmetries. A modified double ring configuration of the single transmitter and multiple receiver compact array was developed to experimentally validate the blind inversion approach on a quasi-isotropic graphite-epoxy composite plate. This technique finds application in the area of material characterization and structural health monitoring of anisotropic platelike structures.

  8. Developments in variational methods for high performance plate and shell elements

    NASA Technical Reports Server (NTRS)

    Felippa, Carlos A.; Militello, Carmelo

    1991-01-01

    High performance elements are simple finite elements constructed to deliver engineering accuracy with coarse arbitrary grids. This is part of a series on the variational foundations of high-performance elements, with emphasis on plate and shell elements constructed with the free formulation (FF) and assumed natural strain (ANS) methods. Parameterized variational principles are studied that provide a common foundation for the FF and ANS methods, as well as for a combination of both. From this unified formulation a variant of the ANS formulation, called the assumed natural deviatoric strain (ANDES) formulation, emerges as an important special case. The first ANDES element, a high-performance 9 degrees of freedom triangular Kirchhoff plate bending element, is briefly described to illustrate the use of the new formulation.

  9. Determination of Rock Mass Modulus Using the Plate Loading Method at Yucca Mountain, Nevada

    SciTech Connect

    Finley, R.E.; George, J.T.; Riggins, M.

    1999-08-02

    A suite of plate loading tests has recently been conducted by Sandia National Laboratories at the Exploratory Studies Facility at Yucca Mountain, Nevada. Fielding of these in situ tests as well as other approaches undertaken for the determination of rock mass modulus are described. The various methodologies are evaluated and their data compared. Calculation by existing empirical methods and numerical modeling are compared to each other as well as to field data.

  10. Effect of different heating methods on deformation of metal plate under upsetting mechanism in laser forming

    NASA Astrophysics Data System (ADS)

    Shi, Yongjun; Liu, Yancong; Yi, Peng; Hu, Jun

    2012-03-01

    In a laser forming process, different forming mechanisms have different deformation behaviors. The aim of laser forming is to acquire plane strain under an upsetting mechanism, while a plate undergoes a small bending deformation. In some industrial applications, the bending strain should not occur. To achieve high-precision forming, the deformation behaviors of a metal plate when an upsetting mechanism plays a dominant role are studied in the paper. Several heating methods are proposed to reduce the plane strain difference along the thickness direction and little bending deformation resulting from a small temperature difference between the top and bottom surfaces of the plate. The results show that negligible bending deformation and a uniform plastic plane strain field can be obtained by simultaneously heating the top and bottom surfaces with the same process parameters. A conventional scanning method needs a larger spot diameter and slower scanning speed under the upsetting mechanism, but a smaller spot diameter and quicker scanning speed may be selected using the simultaneous heating method, which can greatly widen the potential scope of process parameters.

  11. Modification of kanamycin-esculin-azide agar to improve selectivity in the enumeration of fecal streptococci from water samples.

    PubMed Central

    Audicana, A; Perales, I; Borrego, J J

    1995-01-01

    Kanamycin-esculin-azide agar was modified by increasing the concentration of sodium azide to 0.4 g liter-1 and replacing kanamycin sulfate with 5 mg of oxolinic acid liter-1. The modification, named oxolinic acid-esculin-azide (OAA) agar, was compared with Slanetz-Bartley and KF agars by using drinking water and seawater samples. The OAA agar showed higher specificity, selectivity, and recovery efficiencies than those obtained by using the other media. In addition, no confirmation of typical colonies was needed when OAA agar was used, which significantly shortens the time of sample processing and increases the accuracy of the method. PMID:8534085

  12. A Comprehensive Study of Internal Distraction Plating, an Alternative Method for Distal Radius Fractures

    PubMed Central

    Mavani, Kinjal J

    2016-01-01

    Introduction The management of highly comminuted distal radius fractures still remains a major treatment challenge. Articular comminution and compromised bone quality are the culprits. One novel approach is the technique of Internal Distraction Plating which involves “bridging” the fracture with the use of a standard 3.5mm plate applied dorsally in distraction from the radius, proximal to the fracture, to the long finger metacarpal distally, bypassing the comminuted segment. The plate is removed once fracture union has been achieved. Aim The present study was conducted with the aim to evaluate the role of internal dorsal distraction plating as an alternative method in the treatment of fracture distal radius in terms of special indications, technique and outcome. Materials and Methods This study was a prospective longitudinal study on 20 patients (mean age 62 years) treated with internal distraction plating for comminuted distal radius fractures with specific indications. Regular follow-ups with standard radiographs and analysis were done upto 24 months. Functional outcome were assessed by DASH Score and the Gartland and Werley demerit score. Results At final follow-up, all fractures had united and X-rays showed mean palmar tilt of 7°, positive ulnar variance of 0.5mm, radial inclination of 18° and average loss of 2mm of radial height. Mean range of motion values for wrist flexion 46°, extension 50°, pronation 79° and supination 77° At final follow-up, the mean DASH score was 32. 85% patient had excellent to good result as per Gartland and Werley demerit score. This construct has yield satisfactory clinical and radiographic results with these very challenging injuries. Conclusion The purpose of this study was to report the radiographic and the functional outcomes of treatment with this technique. External fixator and volar plating in communited distal end radius fractures are not always satisfactory in old age with osteoporotic bone because of

  13. Method for preparing surfaces of metal composites having a brittle phase for plating

    DOEpatents

    Coates, Cameron W.; Wilson, Thomas J.

    1984-01-01

    The present invention is directed to a method for preparing surfaces of two-phase metal composites having relatively brittle and malleable components for plating with corrosion-resistant material. In practice of the present invention, the surfaces of the composites are etched to remove a major portion or fraction of the brittle component. The etched surface is then peened with particulates for breaking the brittle component from the surfaces and for spreading or smearing the malleable component over the surfaces. The peened surface is then chemically cleaned of residual traces of the brittle component so as to provide a surface of essentially the malleable component to which the corrosion-resistant material may be plated thereon in an adherent manner.

  14. Phenotypic identification of Candida albicans by growth on chocolate agar.

    PubMed

    Sheth, Chirag C; Johnson, Elizabeth; Baker, Mark E; Haynes, Ken; Mühlschlegel, Fritz A

    2005-12-01

    In this study, we describe a simple method for the identification of Candida albicans in clinical samples. A total of 383 clinical isolates of Candida species were streaked onto chocolate agar and incubated for 48 h at 37 degrees C in the presence of an atmosphere of 6% CO2. All 208 of the C. albicans isolates tested, developed an easy to identify filamentous colony morphology. Of 175 other Candida species tested, 172 (98.3%) were distinguishable from C. albicans by their smooth colony morphology. Three isolates (1.7%) exhibited weak filamentation after prolonged incubation. Although not a routine medium in medical mycology a significant advantage of using chocolate agar lies in its use in clinical bacteriology laboratories for the isolation of fastidious bacteria. Implementation of the proposed method is applicable across a range of specimen types, thus allowing the direct identification of C. albicans in clinical samples. This simple method may allow a quicker entry into directed treatment.

  15. Use of agar diffusion assay to evaluate bactericidal activity of formulations of alkaline salts of fatty acids against bacteria associated with poultry processing

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The agar diffusion assay was used to examine antibacterial activity of alkaline salts of fatty acids (FA). Wells in agar media seeded with bacteria were filled with FA-potassium hydroxide (KOH) solutions, plates were incubated, and zones of inhibition were measured. The relationship between bacteric...

  16. Effect of Output Bar Supporting Methods on High Velocity Tensile Behavior for Steel Plate

    NASA Astrophysics Data System (ADS)

    Itabashi, Masaaki

    In order to obtain precise and correct dynamic stress-strain behavior for steel plate, the split Hopkinson (Kolsky) bar method or the one bar method has been adopted as a testing method. In these two methods, a dynamic load transducer is the thin steel bar (s). On the input and output bars, typically two or four strain gages are adhered at the same distance from the end of the bars to detect elastic strains of the bars as dynamic load signal. The bars are usually mounted on simple supports, allowing a little axial elongation of the bars. Then, ball bearings or polytetrafluoroethylene parts are frequently installed between the bars and supports, because the friction between them will affect the quality of the dynamic load signal. On the other hand, only for the one bar method, it is reported that a relatively tight support, neighboring the loading end of the output bar, is effective to reduce an extraordinarily-high initial stress peak on dynamic stress-strain curve. In this paper, some trials have been carried out to find the optimum supporting condition for the output bar loading end in the one bar method. An assembly for a steel plate specimen is connected to an impact block. The other end of the assembly is an extension of the output bar. Usually, from the end of gage length of the specimen plate, there is no output bar support within approximately 650mm, for the present apparatus. This situation is designated as “no support”. At a location of 60mm from the end of the gage length, a simple output bar support is introduced additionally. This situation is called as “simple support”, because the output bar is left on the V-shaped top of the support. Additional upper supporting parts can be installed to the simple support condition. After the installation, a square hole is formed on the top of the support. The output bar touches four sides of the hole. This situation is called as “surrounding support”. In addition, specimen assembly types are also

  17. Pigments of fly agaric (Amanita muscaria).

    PubMed

    Stintzing, Florian; Schliemann, Willibald

    2007-01-01

    The complex pigment pattern of fly agaric (Amanita muscaria) cap skins has been studied by LC-DAD and mass spectrometry. Among the betaxanthins the corresponding derivatives of serine, threonine, ethanolamine, alanine, Dopa, phenylalanine and tryptophan are reported for the first time to contribute to the pigment pattern of fly agarics. Betalamic acid, the chromophoric precursor of betaxanthins and betacyanins, muscaflavin and seco-dopas were also detected. Furthermore, the red-purple muscapurpurin and the red muscarubrin were tentatively assigned while further six betacyanin-like components could not be structurally allocated. Stability studies indicated a high susceptibility of pigment extracts to degradation which led to rapid colour loss thus rendering a complete characterization of betacyanin-like compounds impossible at present. Taking into account these difficulties the presented results may be a starting point for a comprehensive characterization of the pigment composition of fly agarics.

  18. The analysis of the accuracy of the wheel alignment inspection method on the side-slip plate stand

    NASA Astrophysics Data System (ADS)

    Gajek, A.; Strzępek, P.

    2016-09-01

    The article presents the theoretical basis and the results of the examination of the wheel alignment inspection method on the slide slip plate stand. It is obligatory test during periodic technical inspection of the vehicle. The measurement is executed in the dynamic conditions. The dependence between the lateral displacement of the plate and toe-in of the tested wheels has been shown. If the diameter of the wheel rim is known then the value of the toe-in can be calculated. The comparison of the toe-in measurements on the plate stand and on the four heads device for the wheel alignment inspection has been carried out. The accuracy of the measurements and the influence of the conditions of the tests on the plate stand (the way of passing through the plate) were estimated. The conclusions about the accuracy of this method are presented.

  19. Apparatus and method for explosive bonding to edge of flyer plate

    NASA Technical Reports Server (NTRS)

    Bement, Laurence J. (Inventor); Kushnick, Anne C. (Inventor)

    1991-01-01

    The invention is an apparatus and a process for the explosive joining of a flyer plate and a base plate. The apparatus consists of a flyer plate positioned over a base plate. The flyer plate has a notch containing a filler material in intimate contact with the flyer plate. An adhesive means holds a ribbon explosive partially overlapping the notch in the flyer plate. A detonating means initiates the ribbon explosive that drives the flyer plate to accomplish a high velocity, angular collision between the mating surfaces. This collision creates surface melts and effacing bonding, resulting in electron sharing linkups between the plates. An unbonded tab fractures at a base of the notch leaving a bond to an edge of the attached flyer plate.

  20. Comparison of seven plating media for enumeration of Listeria spp.

    PubMed Central

    Loessner, M J; Bell, R H; Jay, J M; Shelef, L A

    1988-01-01

    The suitability of seven media for the enumeration of Listeria spp. was evaluated at 30 degrees C for 48 h. The media tested were (i) the original McBride Listeria agar formulation (with glycine); (ii) modified McBride agar containing glycine anhydride; (iii) LiCl-phenylethanol-moxalactam (LPM) agar; (iv) acriflavine-ceftazidime agar; (v) Rodriguez isolation agar (RISA); (vi) modified Vogel-Johnson (MVJ) agar; (vii) cyclohexanedione-nalidixic acid-phenylethanol agar; and tryptose agar as control. A total of 66 organisms were used including 11 Listeria monocytogenes strains and 5 other Listeria spp. For L. monocytogenes strains only, all media performed highly similarly. Of the other Listeria spp., only two grew on MVJ agar and three each grew on LPM and RISA. Only LPM agar inhibited the 50 non-listeriae, including five yeasts, while MVJ agar inhibited all but one yeast. The McBride Listeria agar formulation that contained glycine anhydride was less selective than the original. When pure cultures of 10 bacteria (including one L. monocytogenes strain) were combined and plated on four media, L. monocytogenes colonies were easiest to enumerate on MVJ agar, followed by LPM and RISA. These media ranked in the same order when plated with homogenates of various foods to which was added L. monocytogenes Scott A, but LPM agar was the best overall since Scott A was inhibited by MVJ. Upon microscopic examination of listerial colonies from the plating media, atypical cell morphology was noted with cells being about twofold in size on LPM, MVJ, and acriflavine-ceftazidime agars. Overall, LPM agar was the most suitable of the media tested even though it was inhibitory to Listeria grayi and Listeria murrayi. PMID:3146947

  1. Comparison of Culture-Based Methods for Identification of Colonization with Methicillin-Resistant and Methicillin-Susceptible Staphylococcus aureus in the Context of Cocolonization

    PubMed Central

    Hu, Baofeng; Carroll, Karen C.; Bilker, Warren B.; Tolomeo, Pam; Cluzet, Valerie C.; Baron, Patrick; Ferguson, Jacqueline M.; Morris, Daniel O.; Rankin, Shelley C.; Lautenbach, Ebbing

    2016-01-01

    Two screening methods to detect staphylococcal colonization in humans were compared. Direct plating to CHROMagar (BD Diagnostics) was compared to a broth preenrichment followed by plating to Baird-Parker agar. The broth-enrichment method was comparable to CHROMagar for methicillin-resistant Staphylococcus aureas (MRSA) detection, but the enrichment method was optimum for recovery of coagulase-positive Staphylococcus spp. PMID:27122377

  2. Comparison of Culture-Based Methods for Identification of Colonization with Methicillin-Resistant and Methicillin-Susceptible Staphylococcus aureus in the Context of Cocolonization.

    PubMed

    Davis, Meghan F; Hu, Baofeng; Carroll, Karen C; Bilker, Warren B; Tolomeo, Pam; Cluzet, Valerie C; Baron, Patrick; Ferguson, Jacqueline M; Morris, Daniel O; Rankin, Shelley C; Lautenbach, Ebbing; Nachamkin, Irving

    2016-07-01

    Two screening methods to detect staphylococcal colonization in humans were compared. Direct plating to CHROMagar (BD Diagnostics) was compared to a broth preenrichment followed by plating to Baird-Parker agar. The broth-enrichment method was comparable to CHROMagar for methicillin-resistant Staphylococcus aureas (MRSA) detection, but the enrichment method was optimum for recovery of coagulase-positive Staphylococcus spp.

  3. Standard operating procedure to prepare agar phantoms

    NASA Astrophysics Data System (ADS)

    Souza, R. M.; Santos, T. Q.; Oliveira, D. P.; Souza, R. M.; Alvarenga, A. V.; Costa-Felix, R. P. B.

    2016-07-01

    Agar phantoms are widely used as soft tissue mimics and some preparation techniques are described in the literature. There are also standards that describe the recipe of a soft tissue mimicking material (TMM). However some details of manufacture process are not clearly defined. The standardization of the phantom's preparation can produce a metrological impact on the results of the acoustic properties measured. In this direction, this paper presents a standard operating procedure (SOP) to prepare the agar TMM described on the IEC 60601-237.

  4. The Efficiency of UVC Radiation in the Inactivation of
Listeria monocytogenes on Beef-Agar Food Models

    PubMed Central

    James, Christian; James, Stephen

    2015-01-01

    Summary The aim of this study is to evaluate the effect of meat content and surface smoothness on the deactivation of Listeria monocytogenes in beef-agar food models achieved by shortwave ultraviolet (UVC) light. Food models with various meat contents were made using chopped beef slices and agar solution. Prepared models together with a Listeria selective agar (LSA) plate and a slice of cooked beef were inoculated with L. monocytogenes and then exposed to UVC light. Population of Listeria reduced to below the level of detection on the LSA plates. As the content of beef in the beef-agar models increased, more L. monocytogenes cells survived. Survival was greatest on the treated cooked slice of beef. To better understand the effect of surface irregularities, a white light interferometer was used to analyse the surface smoothness of beef-agar media and LSA plates. No correlation was observed between the surface roughness of seven out of nine types of produced beef-agar media and the degree of inactivation resulting from UVC radiation at the given dose, whereas, less bacterial cells were killed as beef content of the food models increased. The findings of the current study show that the chemical composition of the treated sample also plays an important role in pathogen resistance and survival, meaning that two samples with similar surface irregularities but different chemical composition might produce very different inactivation results when exposed to UVC light. PMID:27904353

  5. Extended layerwise method for laminated composite plates with multiple delaminations and transverse cracks

    NASA Astrophysics Data System (ADS)

    Li, D. H.; Zhang, X.; Sze, K. Y.; Liu, Y.

    2016-10-01

    In this paper, the extended layerwise method (XLWM), which was developed for laminated composite beams with multiple delaminations and transverse cracks (Li et al. in Int J Numer Methods Eng 101:407-434, 2015), is extended to laminated composite plates. The strong and weak discontinuous functions along the thickness direction are adopted to simulate multiple delaminations and interlaminar interfaces, respectively, whilst transverse cracks are modeled by the extended finite element method (XFEM). The interaction integral method and maximum circumferential tensile criterion are used to calculate the stress intensity factor (SIF) and crack growth angle, respectively. The XLWM for laminated composite plates can accurately predicts the displacement and stress fields near the crack tips and delamination fronts. The thickness distribution of SIF and thus the crack growth angles in different layers can be obtained. These information cannot be predicted by using other existing shell elements enriched by XFEM. Several numerical examples are studied to demonstrate the capabilities of the XLWM in static response analyses, SIF calculations and crack growth predictions.

  6. Polarization characterization of PZT disks and of embedded PZT plates by thermal wave methods

    SciTech Connect

    Eydam, Agnes Suchaneck, Gunnar Gerlach, Gerald; Esslinger, Sophia; Schönecker, Andreas; Neumeister, Peter

    2014-11-05

    In this work, the thermal wave method was applied to characterize PZT disks and embedded PZT plates with regard to the polarization magnitude and spatial homogeneity. The samples were exposed to periodic heating by means of a laser beam and the pyroelectric response was determined. Thermal relaxation times (single time constants or distributions of time constants) describe the heat losses of the PZT samples to the environment. The resulting pyroelectric current spectrum was fitted to the superposition of thermal relaxation processes. The pyroelectric coefficient gives insight in the polarization distribution. For PZT disks, the polarization distribution in the surface region showed a characteristic decrease towards the electrodes.

  7. Using the heat flow plate method for determining thermal conductivity of building materials

    NASA Astrophysics Data System (ADS)

    Flori, M.; Puţan, V.; Vîlceanu, L.

    2017-01-01

    The heat flow plate method is used to determine thermal conductivity of a building material sample made of Rohacell (insulating foam). Experimental technique consists in placing the sample with a reference material on top (polystyrene sample) in a calorimetric chamber and heating from underside. Considering that the heat flux which passes through the two layers is constant and knowing thermal conductivity of the reference material, the sample thermal conductivity is determined. The temperature difference between the two opposite sample’s sides is recorded only when the steady state is achieved (constant heat flux).

  8. Methods of testing to determine the thermal performance of unglazed flat-plate liquid-type solar collectors. (ASHRAE standard)

    SciTech Connect

    1989-01-28

    The purpose of this standard is to provide test methods for determining the thermal performance of unglazed flat-plate liquid-type solar energy collector modules which heat a liquid for low temperature applications.

  9. Numerical Manifold Method for the Forced Vibration of Thin Plates during Bending

    PubMed Central

    Jun, Ding; Song, Chen; Wei-Bin, Wen; Shao-Ming, Luo; Xia, Huang

    2014-01-01

    A novel numerical manifold method was derived from the cubic B-spline basis function. The new interpolation function is characterized by high-order coordination at the boundary of a manifold element. The linear elastic-dynamic equation used to solve the bending vibration of thin plates was derived according to the principle of minimum instantaneous potential energy. The method for the initialization of the dynamic equation and its solution process were provided. Moreover, the analysis showed that the calculated stiffness matrix exhibited favorable performance. Numerical results showed that the generalized degrees of freedom were significantly fewer and that the calculation accuracy was higher for the manifold method than for the conventional finite element method. PMID:24883403

  10. Numerical manifold method for the forced vibration of thin plates during bending.

    PubMed

    Jun, Ding; Song, Chen; Wei-Bin, Wen; Shao-Ming, Luo; Xia, Huang

    2014-01-01

    A novel numerical manifold method was derived from the cubic B-spline basis function. The new interpolation function is characterized by high-order coordination at the boundary of a manifold element. The linear elastic-dynamic equation used to solve the bending vibration of thin plates was derived according to the principle of minimum instantaneous potential energy. The method for the initialization of the dynamic equation and its solution process were provided. Moreover, the analysis showed that the calculated stiffness matrix exhibited favorable performance. Numerical results showed that the generalized degrees of freedom were significantly fewer and that the calculation accuracy was higher for the manifold method than for the conventional finite element method.

  11. Method of producing exfoliated graphite composite compositions for fuel cell flow field plates

    SciTech Connect

    Zhamu, Aruna; Shi, Jinjun; Guo, Jiusheng; Jang, Bor Z

    2014-04-08

    A method of producing an electrically conductive composite composition, which is particularly useful for fuel cell bipolar plate applications. The method comprises: (a) providing a supply of expandable graphite powder; (b) providing a supply of a non-expandable powder component comprising a binder or matrix material; (c) blending the expandable graphite with the non-expandable powder component to form a powder mixture wherein the non-expandable powder component is in the amount of between 3% and 60% by weight based on the total weight of the powder mixture; (d) exposing the powder mixture to a temperature sufficient for exfoliating the expandable graphite to obtain a compressible mixture comprising expanded graphite worms and the non-expandable component; (e) compressing the compressible mixture at a pressure within the range of from about 5 psi to about 50,000 psi in predetermined directions into predetermined forms of cohered graphite composite compact; and (f) treating the so-formed cohered graphite composite to activate the binder or matrix material thereby promoting adhesion within the compact to produce the desired composite composition. Preferably, the non-expandable powder component further comprises an isotropy-promoting agent such as non-expandable graphite particles. Further preferably, step (e) comprises compressing the mixture in at least two directions. The method leads to composite plates with exceptionally high thickness-direction electrical conductivity.

  12. Quantification of the spatial strain distribution of scoliosis using a thin-plate spline method.

    PubMed

    Kiriyama, Yoshimori; Watanabe, Kota; Matsumoto, Morio; Toyama, Yoshiaki; Nagura, Takeo

    2014-01-03

    The objective of this study was to quantify the three-dimensional spatial strain distribution of a scoliotic spine by nonhomogeneous transformation without using a statistically averaged reference spine. The shape of the scoliotic spine was determined from computed tomography images from a female patient with adolescent idiopathic scoliosis. The shape of the scoliotic spine was enclosed in a rectangular grid, and symmetrized using a thin-plate spline method according to the node positions of the grid. The node positions of the grid were determined by numerical optimization to satisfy symmetry. The obtained symmetric spinal shape was enclosed within a new rectangular grid and distorted back to the original scoliotic shape using a thin-plate spline method. The distorted grid was compared to the rectangular grid that surrounded the symmetrical spine. Cobb's angle was reduced from 35° in the scoliotic spine to 7° in the symmetrized spine, and the scoliotic shape was almost fully symmetrized. The scoliotic spine showed a complex Green-Lagrange strain distribution in three dimensions. The vertical and transverse compressive/tensile strains in the frontal plane were consistent with the major scoliotic deformation. The compressive, tensile and shear strains on the convex side of the apical vertebra were opposite to those on the concave side. These results indicate that the proposed method can be used to quantify the three-dimensional spatial strain distribution of a scoliotic spine, and may be useful in quantifying the deformity of scoliosis.

  13. Silver-halide sensitized gelatin (SHSG) processing method for pulse holograms recorded on VRP plates

    NASA Astrophysics Data System (ADS)

    Evstigneeva, Maria K.; Drozdova, Olga V.; Mikhailov, Viktor N.

    2002-06-01

    One of the most important area of holograph applications is display holography. In case of pulse recording the requirement for vibration stability is easier than compared to CW exposure. At the same time it is widely known that the behavior of sliver-halide holographic materials strongly depends on the exposure duration. In particular the exposure sensitivity drastically decreases under nanosecond pulse duration. One of the effective ways of the diffraction efficiency improvement is SHSG processing method. This processing scheme is based on high modulation of refractive index due to microvoids appearance inside emulsion layer. It should be mentioned that the SHSG method was used earlier only in the cases when the holograms were recorded by use of CW lasers. This work is devoted to the investigation of SHSG method for pulse hologram recording on VRP plates. We used a pulsed YLF:Nd laser with pulse duration of 25 nanoseconds and wavelength of 527 nm. Both transmission and reflection holograms were recorded. The different kinds of bleaching as well as developing solutions were investigated. Our final processing scheme includes the following stages: 1) development in non-tanning solution, 2) rehalogenating bleach, 3) intermediate alcohol drying, 4) uniform second exposure, 5) second development in diluted developer, 6) reverse bleaching, 7) fixing and 8) gradient drying in isopropyl alcohol. Diffraction efficiency of transmission holograms was of about 60 percent and reflection mirror holograms was of about 45 percent. Thus we have demonstrated the SHSG processing scheme for producing effective holograms on VRP plates under pulse exposure.

  14. Vibrations of rectangular plates with moderately large initial deflections at elevated temperatures using finite element method

    NASA Technical Reports Server (NTRS)

    Gray, C. C.

    1990-01-01

    A finite-element formulation is developed for the free vibration of rectangular plates which are under the influence of moderately large stress-free initial deflections and large thermal deflections. The von Karman nonlinear strain-displacement relations are used to account for the thermal deflections. The plates are thin, isotropic, and Hookean in nature. The temperature imposed on the plate is assumed to be constant through the thickness of the plate. Uniform and sinusoidal temperature distributions are studied. The material properties of the plates are temperature-dependent due to the relatively high temperatures imposed on the plates.

  15. Use of agar agar stabilized milled zero-valent iron particles for in situ groundwater remediation

    NASA Astrophysics Data System (ADS)

    Schmid, Doris; Velimirović, Milica; Wagner, Stephan; Micić Batka, Vesna; von der Kammer, Frank; Hofmann, Thilo

    2015-04-01

    A major obstacle for use of nanoscale zero-valent iron (nZVI) particles as a nontoxic material for effective in situ degradation of chlorinated aliphatic hydrocarbons (CAHs) is the high production cost. For that reason, submicro-scale milled zero-valent iron particles were recently developed (milled ZVI, UVR-FIA, Germany) by grinding macroscopic raw materials of elementary iron as a cheaper alternative to products produced by solid-state reduction. However, milled ZVI particles tend to aggregate and due to the rather large particle size (d50= 11.9 µm) also rapidly sediment. To prevent aggregation and consequently sedimentation of milled ZVI particles and therefore improve the mobility after in situ application, the use of a stabilizer is considered in literature as a most promising option. In this study, milled ZVI particles (1 g L-1 of particle concentration) were stabilized by environmentally friendly polymer agar agar (>0.5 g L-1), which had a positive impact on the milled ZVI stability. Sedimentation rate was significantly decreased by increasing the suspension viscosity. Column transport experiments were performed for bare and agar agar stabilized milled ZVI particles in commercially available fine grained quartz sand (DORSILIT® Nr.8, Gebrüder Dorfner GmbH Co, Germany) and different porous media collected from brownfields. The experiments were carried out under field relevant injection conditions of 100 m d-1. The maximal travel distance (LT) of less than 10 cm was determined for non-stabilized suspension in fine grained quartz sand, while agar agar (1 g L-1) stabilized milled ZVI suspension revealed LT of 12 m. Similar results were observed for porous media from brownfields showing that mobility of agar agar stabilized particle suspensions was significantly improved compared to bare particles. Based on the mobility data, agar agar stabilized milled zero-valent iron particles could be used for in situ application. Finally, lab-scale batch degradation

  16. The frequency-domain method of calculation for the pulsed electromagnetic field in a conductive ferromagnetic plate

    NASA Astrophysics Data System (ADS)

    Nosov, G. V.; Kuleshova, E. O.; Lefebvre, S.; Plyusnin, A. A.; Tokmashev, D. M.

    2017-02-01

    The technique for parameters determination of magnetic skin effect on ferromagnetic plate at a specified pulse of magnetic field intensity on the plate surface is proposed. It is based on a frequency-domain method and could be applied for a pulsing transformer, a dynamoelectric pulse generator and a commutating inductor that contains an imbricated core. Due to this technique, such plate parameters as specific heat loss energy, the average power of this energy and the plate temperature raise, the magnetic flux attenuation factor and the plate q-factor could be calculated. These parameters depend on the steel type, the amplitude, the rms value, the duration and the form of the magnetic field intensity impulse on the plate surface. The plate thickness is defined by the value of the flux attenuation factor and the plate q-factor that should be maximal. The reliability of the proposed technique is built on a common frequency-domain usage applicable for pulse transient study under zero boundary conditions of the electric circuit and the conformity of obtained results with the sinusoidal steady-state mode.

  17. Normal force controlled rheology applied to agar gelation

    NASA Astrophysics Data System (ADS)

    Mao, Bosi; Divoux, Thibaut; Snabre, Patrick

    2016-05-01

    A wide range of thermoreversible gels are prepared by cooling down to ambient temperature hot aqueous polymer solutions. During the sol-gel transition, such materials may experience a volume contraction which is traditionally overlooked as rheological measurements are usually performed in geometries of constant volume. In this article, we revisit the formation of 1.5\\% wt. agar gels through a series of benchmark rheological experiments performed with a plate-plate geometry. We demonstrate on that particular gel of polysaccharides that the contraction associated with the sol/gel transition cannot be neglected. Indeed, imposing a constant gap width during the gelation results in the strain hardening of the sample, as evidenced by the large negative normal force that develops. Such hardening leads to the slow drift in time of the gel elastic modulus $G'$ towards ever larger values, and thus to an erroneous estimate of $G'$. As an alternative, we show that imposing a constant normal force equals to zero during the gelation, instead of a constant gap width, suppresses the hardening as the decrease of the gap compensates for the sample contraction. Using normal force controlled rheology, we then investigate the impact of thermal history on 1.5\\% wt. agar gels. We show that neither the value of the cooling rate, nor the introduction of a constant temperature stage during the cooling process influence the gel elastic properties. Instead, $G'$ only depends on the terminal temperature reached at the end of the cooling ramp, as confirmed by direct imaging of the gel microstructure by cryoelectron microscopy. The present work offers an extensive review of the technical difficulties associated with the rheology of hydrogels and paves the way for a systematic use of normal force controlled rheology to monitor non-isochoric processes.

  18. Comparison of dosimetry gels prepared by agar and bovine gelatine

    NASA Astrophysics Data System (ADS)

    Sağsöz, M. E.; Korkut, Ö.; Alemdar, N.; Aktaş, S.; Çalı, E. B.; Kantarcı, M.

    2016-04-01

    Gel dosimeters are unique materials capable of showing three dimensional (3D) dose distributions of therapeutic or diagnostic exposures. Fricke gel dosimeters can be considered as chemical dosimeters that rely on a radiation-induced chemical reaction. Dose distribution of Fricke solutions containing Fe+2 ions determines the transformation of acidic, oxygen saturated Fe+2 ions to Fe+3 ions by the ionizing radiation in aqueous solutions. In this study we produced two different types of gel dosimeters using agar and bovine gelatin with similar fabrication methods. We compared the magnetic resonance (MR) T1 imaging responses of these two gel dosimeters to acquire a dose dependency of MR intensities. In conclusion agar gel dosimeters found to be produced easily and more consistent.

  19. The Lagrangian multiplier method of finding upper and lower limits to critical stresses of clamped plates

    NASA Technical Reports Server (NTRS)

    Budiansky, Bernard; Hu, Pai C

    1946-01-01

    The theory of Lagrangian multipliers is applied to the problem of finding both upper and lower limits to the true compressive buckling stress of a clamped rectangular plate. The upper and lower limits thus bracket the true stress, which cannot be exactly found by the differential-equation approach. The procedure for obtaining the upper limit, which is believed to be new, presents certain advantages over the classical Rayleigh-Ritz method of finding upper limits. The theory of the lower-limit procedure has been given by Trefftz, but, in the present application, the method differs from that of Trefftz in a way that makes it inherently more quickly convergent. It is expected that in other buckling problems and in some vibration problems the Lagrangian multiplier method of finding upper and lower limits may be advantageously applied to the calculation of buckling stresses and natural frequencies.

  20. Vectorization and parallelization of the finite strip method for dynamic Mindlin plate problems

    NASA Technical Reports Server (NTRS)

    Chen, Hsin-Chu; He, Ai-Fang

    1993-01-01

    The finite strip method is a semi-analytical finite element process which allows for a discrete analysis of certain types of physical problems by discretizing the domain of the problem into finite strips. This method decomposes a single large problem into m smaller independent subproblems when m harmonic functions are employed, thus yielding natural parallelism at a very high level. In this paper we address vectorization and parallelization strategies for the dynamic analysis of simply-supported Mindlin plate bending problems and show how to prevent potential conflicts in memory access during the assemblage process. The vector and parallel implementations of this method and the performance results of a test problem under scalar, vector, and vector-concurrent execution modes on the Alliant FX/80 are also presented.

  1. Possible influence of surfactants and proteins on the efficiency of contact agar microbiological surface sampling.

    PubMed

    Deckers, Sylvie M; Sindic, Marianne; Anceau, Christine; Brostaux, Yves; Detry, Jean G

    2010-11-01

    Agar contact microbiological sampling techniques, based on a transfer of the microorganisms present on a surface to a culture medium, are widely used to assess and control surface cleanliness and to evaluate microbial contamination levels. The effectiveness of these techniques depends on many environmental parameters that influence the strength of attachment of the bacteria to the surface. In the present study, stainless steel and high density polyethylene surfaces were inoculated with known concentrations of Staphylococcus epidermidis. Following an experimental design, the surfaces were sampled with different types of replicate organism direct agar contact plates and Petrifilm; results indicated that recovery rates were influenced by the presence of egg white albumin or Tween 80 in the inoculum solutions or by the introduction of surfactants into the contact agar of the microbiological sampling techniques. The techniques yielded significantly different results, depending on sampling conditions, underlining the need for a standardization of laboratory experiments to allow relevant comparisons of such techniques.

  2. Liquid crystal thermography. A method for monitoring temperature gradients in microtitration plates.

    PubMed

    Oliver, D G; Sanders, A H; Jang, L; Poy, D; Van Heuvelen, A

    1983-03-11

    Precise quantitative heat transfer information in microtitration plates can be obtained by filling the wells of a microtitration plate with cholesteric liquid crystals and incubating the plates at the desired temperature in different incubators. The liquid crystals indicate temperature by changes in discrete reproducible colors over various temperature ranges. With these instrumented plates, interwell thermal gradients may be documented visually and are in close agreement with results obtained by using wire thermocouple measuring techniques.

  3. Orifice plate for controlling solids flow, methods of use thereof and articles comprising the same

    DOEpatents

    Jukkola, Glen D.; Teigen, Bard C.

    2017-01-31

    Disclosed herein is an orifice plate comprising one or more plates having orifices disposed therein; the orifices being operative to permit the flow of solids from a moving bed heat exchanger to a solids flow control system; where the orifice plate is downstream of a tube bundle of the moving bed heat exchanger and upstream of the solids flow control system and wherein the orifice plate is operative to evenly distribute the flow of solids in the solids flow control system.

  4. Detection of Agar, by Analysis of Sugar Markers, Associated with Bacillus Anthracis Spores, After Culture

    SciTech Connect

    Wunschel, David S.; Colburn, Heather A.; Fox, Alvin; Fox, Karen F.; Harley, William M.; Wahl, Jon H.; Wahl, Karen L.

    2008-08-01

    Detection of small quantities of agar associated with spores of Bacillus anthracis could provide key information regarding its source or growth characteristics. Agar, widely used in growth of bacteria on solid surfaces, consists primarily of repeating polysaccharide units of 3,6-anhydro-L-galactose (AGal) and galactose (Gal) with sulfated and O-methylated galactoses present as minor constituents. Two variants of the alditol acetate procedure were evaluated for detection of potential agar markers associated with spores. The first method employed a reductive hydrolysis step, to stabilize labile anhydrogalactose, by converting to anhydrogalactitol. The second eliminated the reductive hydrolysis step simplifying the procedure. Anhydrogalactitol, derived from agar, was detected using both derivatization methods followed by gas chromatography-mass spectrometry (GC-MS) analysis. However, challenges with artefactual background (reductive hydrolysis) or marker destruction (hydrolysis) lead to the search for alternative sugar markers. A minor agar component, 6-O-methyl galactose (6-O-M gal), was readily detected in agar-grown but not broth-grown bacteria. Detection was optimized by the use of gas chromatography-tandem mass spectrometry (GC-MS-MS). With appropriate choice of sugar marker and analytical procedure, detection of sugar markers for agar has considerable potential in microbial forensics.

  5. A dual reciprocity boundary element solution method for the free vibration analysis of fluid-coupled Kirchhoff plates

    NASA Astrophysics Data System (ADS)

    Uğurlu, B.

    2015-03-01

    A boundary element solution method is proposed for linear vibration analysis of fluid-coupled thin plates. The method is based on replacing the associated biharmonic operator with two successive harmonic operators, leading to a coupled system of boundary integral equations with simpler properties: the fundamental solution has an elementary form, and complicated singularity removal techniques can be avoided. The fluid flow due to the plate motion is taken as a potential field, and its effect on the plate dynamics is incorporated into the analysis by invoking another boundary integral solution, described over the fluid-plate interface. The body terms in the plate boundary integral equations are considered by the dual reciprocity boundary element formulation. Three different radial basis functions are employed as interpolation functions, alone and augmented with polynomial and sine expansions, to represent the body terms. The performance of the method is investigated from several perspectives by adopting plates with different shapes and/or boundary conditions; excellent approximations are obtained in general: the convergence behavior is consistent, both dry and wet frequency parameters are predicted accurately, and the mode shapes are captured even with rough models. In some of the studied problems, however, deviated results are obtained for specific modes. Furthermore, it is observed that the performance of the method depends on the implemented DRM functions, and combining radial basis functions with global expansions does not yield noticeable improvements.

  6. Optical Performance Evaluation and Aligning Method for Solid Immersion Lens Assembly with Wedge Plate Lateral Shearing Interferometer

    NASA Astrophysics Data System (ADS)

    Lee, Jin-Eui; Kim, Wan-Chin; Kim, Tae-Seob; Choi, Hyun; Yoon, Yong-Joong; Park, No-Cheol; Park, Young-Pil

    2007-08-01

    We present a simple and stable optical performance evaluation and aligning method for a solid immersion lens (SIL) assembly with a wedge plate lateral shearing interferometer (LSI). There are many advantages in the use of the wedge plate LSI compared with a current SIL measurement method using a Twyman-Green interferometer. We designed the thicknesses, wedge angles, materials, and reflectances of the first and second surfaces of the wedge plate to be 1 mm, 0.02°, fused silica and 21, and 30%, respectively. Simulation and experimental results are well matched in quantitative analyses at shear ratios of 10, 40, and 70%. On the basis of simulation results for an aberrated SIL assembly with many misaligned cases, we suggested the use of the aligning process with the wedge plate LSI.

  7. Evaluation of Ground Bearing Capacity Estimation Methods Based On Plate Loading Tests

    NASA Astrophysics Data System (ADS)

    Gül, Yavuz; Ceylanoğlu, Atilla

    2016-10-01

    Within the scope of this study, bearing capacities were calculated based on eleven different estimation methods in literature, using some mass and material properties for different rock units (magnetite, syenite, serpentinite, limestone, clayey limestone and gypsum) encountered in three different open-pit mines (Sivas-Ulaş Open-Pit Celestite Mine, Divriği Open-Pit Iron Mine and Kangal Open-Pit Coal Mine) around Sivas in Turkey. Through regression analyses between estimated bearing capacity values and those that had been determined as a result of plate loading tests, bearing capacity estimation methods specified in the literature were assessed. Moreover, four different equations to be used in bearing capacity estimation were proposed.

  8. Application of hydrogen analysis by neutron imaging plate method to Zircaloy cladding tubes

    NASA Astrophysics Data System (ADS)

    Yasuda, Ryou; Nakata, Masahito; Matsubayashi, Masahito; Harada, Katsuya; Hatakeyama, Yuichi; Amano, Hidetoshi

    2003-08-01

    Effectiveness of neutron imaging plate (NIP) method for hydrogen analysis is investigated by using standard samples with known hydrogen concentrations. A relationship between hydrogen concentration in Zircaloy tubes and numerical data in the NIP images was obtained by image analysis process. By using the relationship, local hydrogen concentrations in segregated tubes with heterogeneous hydrogen distribution were estimated in a small area; 0.1 × 0.1 mm 2. Contribution of an oxide film in the tubes to the images is also investigated by using oxidized samples with and without hydrides. In the NIP images of the oxidized samples, oxide film was not recognized in the images of the sample. Results of numerical analysis also show no effect of the oxide film. These results show that the effect of oxygen in the image can be neglected when hydrogen analysis is performed on the Zircaloy tube with oxide film and hydrides by NIP method.

  9. Comparison of Primary Models to Predict Microbial Growth by the Plate Count and Absorbance Methods.

    PubMed

    Pla, María-Leonor; Oltra, Sandra; Esteban, María-Dolores; Andreu, Santiago; Palop, Alfredo

    2015-01-01

    The selection of a primary model to describe microbial growth in predictive food microbiology often appears to be subjective. The objective of this research was to check the performance of different mathematical models in predicting growth parameters, both by absorbance and plate count methods. For this purpose, growth curves of three different microorganisms (Bacillus cereus, Listeria monocytogenes, and Escherichia coli) grown under the same conditions, but with different initial concentrations each, were analysed. When measuring the microbial growth of each microorganism by optical density, almost all models provided quite high goodness of fit (r(2) > 0.93) for all growth curves. The growth rate remained approximately constant for all growth curves of each microorganism, when considering one growth model, but differences were found among models. Three-phase linear model provided the lowest variation for growth rate values for all three microorganisms. Baranyi model gave a variation marginally higher, despite a much better overall fitting. When measuring the microbial growth by plate count, similar results were obtained. These results provide insight into predictive microbiology and will help food microbiologists and researchers to choose the proper primary growth predictive model.

  10. A negative-norm least squares method for Reissner-Mindlin plates

    NASA Astrophysics Data System (ADS)

    Bramble, J. H.; Sun, T.

    1998-07-01

    In this paper a least squares method, using the minus one norm developed by Bramble, Lazarov, and Pasciak, is introduced to approximate the solution of the Reissner-Mindlin plate problem with small parameter t, the thickness of the plate. The reformulation of Brezzi and Fortin is employed to prevent locking. Taking advantage of the least squares approach, we use only continuous finite elements for all the unknowns. In particular, we may use continuous linear finite elements. The difficulty of satisfying the inf-sup condition is overcome by the introduction of a stabilization term into the least squares bilinear form, which is very cheap computationally. It is proved that the error of the discrete solution is optimal with respect to regularity and uniform with respect to the parameter t. Apart from the simplicity of the elements, the stability theorem gives a natural block diagonal preconditioner of the resulting least squares system. For each diagonal block, one only needs a preconditioner for a second order elliptic problem.

  11. Comparison of Primary Models to Predict Microbial Growth by the Plate Count and Absorbance Methods

    PubMed Central

    Pla, María-Leonor; Oltra, Sandra; Esteban, María-Dolores; Andreu, Santiago; Palop, Alfredo

    2015-01-01

    The selection of a primary model to describe microbial growth in predictive food microbiology often appears to be subjective. The objective of this research was to check the performance of different mathematical models in predicting growth parameters, both by absorbance and plate count methods. For this purpose, growth curves of three different microorganisms (Bacillus cereus, Listeria monocytogenes, and Escherichia coli) grown under the same conditions, but with different initial concentrations each, were analysed. When measuring the microbial growth of each microorganism by optical density, almost all models provided quite high goodness of fit (r2 > 0.93) for all growth curves. The growth rate remained approximately constant for all growth curves of each microorganism, when considering one growth model, but differences were found among models. Three-phase linear model provided the lowest variation for growth rate values for all three microorganisms. Baranyi model gave a variation marginally higher, despite a much better overall fitting. When measuring the microbial growth by plate count, similar results were obtained. These results provide insight into predictive microbiology and will help food microbiologists and researchers to choose the proper primary growth predictive model. PMID:26539483

  12. Methods and formulas for calculating the strength of plate and shell constructions as used in airplane design

    NASA Technical Reports Server (NTRS)

    Heck, O S; Ebner, H

    1936-01-01

    This report is a compilation of previously published articles on formulas and methods of calculation for the determination of the strength and stability of plate and shell construction as employed in airplane design. In particular, it treats the problem of isotropic, orthotopic, and stiffened rectangular plates, thin curved panels, and circular cylinders under various loading conditions. The purpose of appending the pertinent literature references following the subjects discussed was to facilitate a comprehensive study of the treated problems.

  13. A rapid microtiter plate method for the detection of lysozyme release from human neutrophils.

    PubMed

    Moreira-Ludewig, R; Healy, C T

    1992-04-01

    An improved method was devised to measure lysozyme secreted from human neutrophils [polymorphonuclear leukocyte (PMN)] using a microtiter plate reader capable of analyzing enzyme kinetics. The assay is an adaptation of the classical photometric method which detects changes in the turbidity of a bacterial suspension, Micrococcus lysodeikticus, caused by the enzymatic activity of lysozyme. A standard curve using chicken egg white lysozyme was generated, and activity was detectable between the range of 1 and 100 ng/ml. Leukotriene B4 (LTB4)-induced lysozyme release from human PMN was comparable in both the standard assay and the microtiter plate adaptation with EC50 values of 6.5 and 7.2 nM, respectively. Other select stimuli and their receptor antagonists were also used to evaluate the method. Dose-response curves for chemotactic hexapeptide (CHP), recombinant human C5a (rhC5a), and platelet-activating factor (PAF) resulted in EC50 values of 0.14, 0.80, and 542.00 nM, respectively. Inhibition of lysozyme release was studied using receptor antagonists N-t-Boc-L-methionyl-L-leucyl-L-phenylalanine (N-t-Boc), LY223982, and protamine, which are putative inhibitors of formyl peptides (i.e., CHP), LTB4, and C5a, respectively. N-t-Boc inhibited CHP-induced (0.2 nM) enzyme release with an IC50 of 2 microM; LY223982 blocked LTB4-induced (20 nM) release resulting in an IC50 of 52 nM; and protamine inhibited rhC5a-induced (1.5 nM) release with an IC50 of 2 microM. Further studies revealed that CHP, LTB4, and rhC5a were selectively inhibited by their respective antagonists, albeit LY223982 and protamine were also weak inhibitors of CHP and LTB4, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Coupling equivalent plate and finite element formulations in multiple-method structural analyses

    NASA Technical Reports Server (NTRS)

    Giles, Gary L.; Norwood, Keith

    1994-01-01

    A coupled multiple-method analysis procedure for use late in conceptual design or early in preliminary design of aircraft structures is described. Using this method, aircraft wing structures are represented with equivalent plate models, and structural details such as engine/pylon structure, landing gear, or a 'stick' model of a fuselage are represented with beam finite element models. These two analysis methods are implemented in an integrated multiple-method formulation that involves the assembly and solution of a combined set of linear equations. The corresponding solution vector contains coefficients of the polynomials that describe the deflection of the wing and also the components of translations and rotations at the joints of the beam members. Two alternative approaches for coupling the methods are investigated; one using transition finite elements and the other using Lagrange multipliers. The coupled formulation is applied to the static analysis and vibration analysis of a conceptual design model of a fighter aircraft. The results from the coupled method are compared with corresponding results from an analysis in which the entire model is composed of finite elements.

  15. The Anderson--Baird-Parker direct plating method versus the most probable number procedure for enumerating Escherichia coli in meats.

    PubMed

    Rayman, M K; Aris, B

    1981-01-01

    Comparison of the Anderson--Baird-Parker direct plating method (DP) and the North American most probable number procedure (MPN) for enumerating Escherichia coli in frozen meats revealed that the DP method is more precise and yields higher counts of E. coli than the MPN procedure. Any of three brands of membrane filters tested was suitable for use in the DP method.

  16. Fourier series methods for cracks in polygonal plates and shells of revolution

    NASA Astrophysics Data System (ADS)

    Kwok, Frankie Man Wai

    The objective of the study is to develop efficient numerical methods of solving fracture mechanics problems. In addition to computational efficiency, these methods must require minimal user set-up times. A final criterion is the avoidance of special crack-tip elements to capture the singular behavior. The first part of the study focuses on cracked polygonal plates under anti-plane loading. The basis of this work is the Fourier series method, which transforms a problem with a complicated geometry into a summation of half-plane problems. Through this method, the problem takes the form of a matrix equation, solution of which gives the out-of-plane displacement at any point in the plate. With this solution, the J-integral is found to be an accurate and efficient method of obtaining the stress intensity factor. A number of examples are given to illustrate the versatility of this Fourier series method. The second part of the study continues onward to shells of revolution with circumferential through cracks. The shell problem is formulated as a state vector equation. With an asymptotic-numeric procedure, the edge stiffness matrix for each Fourier circumferential harmonic is obtained. The next step involves constructing the expansion and contraction matrices, which relate the Fourier harmonics of the crack domain to those of the whole circumferential domain. By combining the edge stiffness matrices with the expansion and contraction matrices, a matrix equation is formed. Solution of this equation yields the crack-face displacements satisfying the traction free condition in the crack domain. Numerous examples are presented, which include cracks at the middle sections or fixed ends of cylindrical shells under tensile, bending, or torsional loads. With the above methods, various fracture mechanics parameters can be obtained. These include the crack driving force, the stress intensity factor, the crack opening displacement and area. For the anti-plane problem, stress intensity

  17. Experimental comparison and validation of hot-ball method with guarded hot plate method on polyurethane foams

    NASA Astrophysics Data System (ADS)

    Hudec, Ján; Glorieux, Christ; Dieška, Peter; Kubičár, Ľudovít

    2016-07-01

    The Hot-ball method is an innovative transient method for measuring thermophysical properties. The principle is based on heating of a small ball, incorporated in measured medium, by constant heating power and simultaneous measuring of the ball's temperature response since the heating was initiated. The shape of the temperature response depends on thermophysical properties of the medium, where the sensor is placed. This method is patented by Institute of Physics, SAS, where the method and sensors based on this method are being developed. At the beginning of the development of sensors for this method we were oriented on monitoring applications, where relative precision is much more important than accuracy. Meanwhile, the quality of sensors was improved good enough to be used for a new application - absolute measuring of thermophysical parameters of low thermally conductive materials. This paper describes experimental verification and validation of measurement by hot-ball method. Thanks to cooperation with Laboratory of Soft Matter and Biophysics of Catholic University of Leuven in Belgium, established Guarded Hot Plate method was used as a reference. Details about measuring setups, description of the experiments and results of the comparison are presented.

  18. High accuracy position response calibration method for a micro-channel plate ion detector

    NASA Astrophysics Data System (ADS)

    Hong, R.; Leredde, A.; Bagdasarova, Y.; Fléchard, X.; García, A.; Müller, P.; Knecht, A.; Liénard, E.; Kossin, M.; Sternberg, M. G.; Swanson, H. E.; Zumwalt, D. W.

    2016-11-01

    We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an in situ calibration mask, an accuracy of 8 μm and a resolution of 85 μm (FWHM) have been achieved for MeV-scale α particles and ions with energies of ∼10 keV. At this level of accuracy, the difference between the MCP position responses to high-energy α particles and low-energy ions is significant. The improved performance of the MCP detector can find applications in many fields of AMO and nuclear physics. In our case, it helps reducing systematic uncertainties in a high-precision nuclear β-decay experiment.

  19. Piezoelectrically forced vibrations of electroded doubly rotated quartz plates by state space method

    NASA Technical Reports Server (NTRS)

    Chander, R.

    1990-01-01

    The purpose of this investigation is to develop an analytical method to study the vibration characteristics of piezoelectrically forced quartz plates. The procedure can be summarized as follows. The three dimensional governing equations of piezoelectricity, the constitutive equations and the strain-displacement relationships are used in deriving the final equations. For this purpose, a state vector consisting of stresses and displacements are chosen and the above equations are manipulated to obtain the projection of the derivative of the state vector with respect to the thickness coordinate on to the state vector itself. The solution to the state vector at any plane is then easily obtained in a closed form in terms of the state vector quantities at a reference plane. To simplify the analysis, simple thickness mode and plane strain approximations are used.

  20. [A new plate method for screening of polysaccharide-degrading enzymes and their producing microorganisms].

    PubMed

    Ma, Xiang-Dong; Ke, Tao; Xiong, Lan; Yan, Hong; Ma, Li-Xin

    2007-12-01

    A plate assay based on the formation of haloes on Petri dishes, containing the trypan blue dye and polysaccharides as substrates, provides a specific, reliable and rapid detection of corresponding polysaccharide degrading enzymes and their producing microorganisms. A blue complex was formed by mixing trypan blue and polysaccharides as substrates. It has been proved by testing three strains that the trypan blue was neither harmful to microorganisms nor enzymes and could stand the normal sterilization. It's optimum concentration was from 0.005% to 0.01% (W/V). It do not need to prepare dye-labelled polysaccharides, so is a money and time-consuming method. The sensitivity of trypan blue method was the same as traditional method and it has potential for increasing the efficacy of screening of microorganisms, utilizing different polysaccharides, especially for large-scale searching programs, such as screening of large numbers of natural samples and engineering bacteria. Using this method, polysaccharide-degrading enzyme genes also has potential of as a new kind of marker gene in gene engineering techniques. According to the result, this method is suitable for detecting cellulase, amylase, pullulanase and mannase, but not suitable for detecting xylanase and inulinase.

  1. Single Transducer Ultrasonic Imaging Method that Eliminates the Effect of Plate Thickness Variation in the Image

    NASA Technical Reports Server (NTRS)

    Roth, Don J.

    1996-01-01

    This article describes a single transducer ultrasonic imaging method that eliminates the effect of plate thickness variation in the image. The method thus isolates ultrasonic variations due to material microstructure. The use of this method can result in significant cost savings because the ultrasonic image can be interpreted correctly without the need for machining to achieve precise thickness uniformity during nondestructive evaluations of material development. The method is based on measurement of ultrasonic velocity. Images obtained using the thickness-independent methodology are compared with conventional velocity and c-scan echo peak amplitude images for monolithic ceramic (silicon nitride), metal matrix composite and polymer matrix composite materials. It was found that the thickness-independent ultrasonic images reveal and quantify correctly areas of global microstructural (pore and fiber volume fraction) variation due to the elimination of thickness effects. The thickness-independent ultrasonic imaging method described in this article is currently being commercialized under a cooperative agreement between NASA Lewis Research Center and Sonix, Inc.

  2. Estimation of plate material properties by means of a complex wavenumber fit using Hankel's functions and the image source method

    NASA Astrophysics Data System (ADS)

    Roozen, N. B.; Leclère, Q.; Ege, K.; Gerges, Y.

    2017-03-01

    This paper presents a new wave fitting approach to estimate the frequency dependent material properties of thin isotropic plate structures from an experimentally obtained vibrational field, exciting the plate at a single point. The method projects the measurement data on to an analytical image source model, in which Hankel's functions are used for a description of the wave fields emanating from the point of excitation, including the reflected wave fields from the edges of the finite plate. By minimizing the error between the projected field and the measured field, varying the complex wave number and the source strengths of the image sources, an optimum fit is searched for. Thus the source strengths of the image sources do not need to be determined theoretically, but are estimated from the fit on to the experimental data instead (thus avoiding difficulties in theoretically assessing the reflection coefficient of the edges of the plate). The approach uses a complex wavenumber fit, enabling the determination of the dynamic stiffness of the plate structure and its damping properties as function of frequency. The method is especially suited for plates with a sufficient amount of damping, excited at high frequencies.

  3. A semi-analytical method to evaluate the dynamic response of functionally graded plates subjected to underwater shock

    NASA Astrophysics Data System (ADS)

    Liang, Xu; Wang, Zhenyu; Wang, Lizhong; Izzuddin, Bassam A.; Liu, Guohua

    2015-02-01

    Functionally graded (FG) plates are of current interest and are widely used in a variety of applications including deep sea exploration and naval/marine and coastal engineering, despite the fact that there has, to date, been little research undertaken on the subject. In order to remedy the situation, an analytical method to investigate the elastic dynamic responses of FG plates to underwater shock is proposed here, their material properties varying by the same exponential law along the thickness direction. Taylor's one dimensional fluid solid interaction (FSI) model is extended to fit a three dimensional model suitable for FG plates. The extended FSI model and Laplace transform are integrated into the state space method, with the transient solution in the time domain being obtained by using the numerical inversion of the Laplace transform. The solutions of the total forces acting throughout the front and back faces in the time domain are derived for the first time. The present method is validated by comparing it with the results of other methods and experiments found in the relevant literature. The influence of the boundary conditions at the backside of the plate and FG parameters on front and back side pressures, cavitations, displacements, stresses and total forces acting throughout the faces are then investigated, with the time progression of the cavitation areas of air-backed plates and water-backed plates being investigated in detail. The method proposed in this paper may prove useful for the future three-dimensional assessment of the response of FG structures when FSI effects are taken into consideration. It is hoped that the results will lead to a full understanding of the mechanism of the interaction between fluid and an FG plate, and that they can be used as benchmark solutions in further research.

  4. Enumeration of total coliforms and E. coli in foods by the SimPlate coliform and E. coli color indicator method and conventional culture methods: collaborative study.

    PubMed

    Feldsine, Philip T; Lienau, Andrew H; Roa, Nerie H; Green, Shannon T

    2005-01-01

    The relative effectiveness of the SimPlate Coliform and E. coli Color Indicator (CEc-CI) method was compared to the AOAC 3-tube Most Probable Number (MPN) methods for enumerating and confirming coliforms and Escherichia coli in foods (966.23 and 966.24). In this study, test portions were prepared and analyzed according to the conditions stated in both the AOAC methods and SimPlate directions for use. Six food types were artificially contaminated with coliform bacteria and E. coli: frozen burritos, frozen broccoli, fluid pasteurized milk, whole almond nut meats, cheese, and powdered cake mix. Method comparisons were conducted. Overall, the SimPlate method demonstrated <0.3 log difference for total coliform and E. coli counts compared to the AOAC reference methods for the majority of food types and levels analyzed. In all cases, the repeatability and reproducibility of the SimPlate CEc-CI method were not different from those of the reference methods and in certain cases, were statistically better than those of the AOAC 3-tube MPN methods. These results indicate that the SimPlate CEc-CI method and the reference culture methods are comparable for enumeration of both total coliforms and E. coli in foods.

  5. Radiographic Comparison of Four Anterior Fusion Methods in Two Level Cervical Disc Diseases : Autograft Plate Fixation versus Cage Plate Fixation versus Stand-Alone Cage Fusion versus Corpectomy and Plate Fixation

    PubMed Central

    Kim, Min-Ki; Jeon, Kwang-Mo; Kim, Tae-Sung

    2012-01-01

    Objective To evaluate radiographic results of anterior fusion methods in two-level cervical disc disease : tricortical autograft and plate fixation (ACDF-AP), cage and plate fixation (ACDF-CP), stand-alone cage (ACDF-CA), and corpectomy and plate fixation (ACCF). Methods The numbers of patients were 70 with a minimum 6 month follow-up (ACDF-AP : 12, ACDF-CP : 27, ACDF-CA : 15, and ACCF : 16). Dynamic simple X-ray and computed tomography were evaluated preoperatively, postoperatively, 6 month, and at the final follow-up. The fusion and subsidence rates at the final were determined, and global cervical lordosis (GCL), cervical range of motion, fused segment angle (FSA), and fused segment height (FSH) were analyzed. Results Nonunion was observed in 4 (25%) patients with ACDF-CA, 1 (8%) patient with ACDF-AP, 1 (4%) patient with ACDF-CP. The number of loss of FSH (%) more than 3 mm were 2 patients (16%) in ACDF-AP, 3 patients (11%) in ACDF-CP, 5 patients (33%) in ACDF-CA, and 3 patients (20%) in ACCF. The GCL was decreased with ACDF-CA and increased with others. The FSA was increased with ACDF-AP, ACDF-CP, and ACCF, but ACDF-CA was decreased. At the final follow-up, the FSH was slightly decreased in ACDF-CP, ACDF-AP, and ACCF, but ACDF-CA was more decreased. Graft related complication were minimal. Screw loosening, plate fracture, cage subsidence and migration were not identified. Conclusion ACDF-CP demonstrated a higher fusion rate and less minimal FSH loss than the other fusions in two-level cervical disc disease. The ACDF-AP and ACCF methods had a better outcome than the ACDF-CA with respect to GCL, FSA, and FSH. PMID:22639708

  6. Low density, microcellular, dopable, agar/gelatin foams for pulsed power experiments

    SciTech Connect

    McNamara, W.F.; Aubert, J.H.

    1997-04-01

    Low-density, microcellular foams prepared from the natural polymers agar and gelatin have been developed for pulsed-power physics experiments. Numerous experiments were supported with foams having densities at or below 10 mg/cm{sup 3}. For some of the experiments, the agar/gelatin foam was uniformly doped with metallic elements using soluble salts. Depending on the method of preparation, cell sizes were typically below 10 microns and for one process were below 1.0 micron.

  7. Tuning of Feedback Decoupling Controller for Two-Dimensional Heat Plate by Using VRFT Method

    NASA Astrophysics Data System (ADS)

    Matsunaga, Nobutomo; Nakano, Masahiko; Okajima, Hiroshi; Kawaji, Shigeyasu

    In manufacturing processes, inappropriate thermal distribution, which is observed in both steady and transient states of the thermal plant, leads to inferior quality. For a plant with strong thermal interaction, decoupling control is effective in precisely tuning the control system. We proposed the decoupling controller based on the temperature-difference feedback model. However, no parameter-identification method of thermal interaction has been presented so far. Traditionally, iterative tuning by trial and error has been used to tune the controller parameters. In the case of an industrial plant, the tuning time would be long because of the large time constants of the plant. Recently, the virtual reference feedback tuning (VRFT) method, which can be used for off-line tuning of the controller parameters using a set of I/O data, has been studied to examine the possibility of shortening the tuning time. In this paper, a VRFT method for the feedback decoupling controller is proposed for a two-dimensional heat plate by taking consideration the thermal interaction property. The effectiveness of this VRFT method is evaluated by performing an experimental simulation.

  8. Quasi-simultaneous interaction method for solving 2D boundary layer flows over plates and airfoils

    NASA Astrophysics Data System (ADS)

    Bijleveld, H. A.; Veldman, A. E. P.

    2012-11-01

    This paper studies unsteady 2D boundary layer flows over dented plates and a NACA 0012 airfoil. An inviscid flow is assumed to exist outside the boundary layer and is solved iteratively with the boundary layer flow together with the interaction method until a matching solution is achieved. Hereto a quasi-simultaneous interaction method is applied, in which the integral boundary layer equations are solved together with an interaction-law equation. The interaction-law equation is an approximation of the external flow and based on thin-airfoil theory. It is an algebraic relation between the velocity and displacement thickness. The interaction-law equation ensures that the eigenvalues of the system of equations do not have a sign change and that no singularities occur. Three numerical schemes are used to solve the boundary layer flow with the interaction method. These are: a standard scheme, a splitting method and a characteristics solver. All schemes use a finite difference discretization. The three schemes yield comparable results for the simulations carried out. The standard scheme is deviating most from the splitting and characteristics solvers. The results show that the eigenvalues remain positive, even in separation. As expected, the addition of the interaction-law equation prevents a sign change of the eigenvalues. The quasi-simultaneous interaction scheme is applicable to the three numerical schemes tested.

  9. Robust scatter correction method for cone-beam CT using an interlacing-slit plate

    NASA Astrophysics Data System (ADS)

    Huang, Kui-Dong; Xu, Zhe; Zhang, Ding-Hua; Zhang, Hua; Shi, Wen-Long

    2016-06-01

    Cone-beam computed tomography (CBCT) has been widely used in medical imaging and industrial nondestructive testing, but the presence of scattered radiation will cause significant reduction of image quality. In this article, a robust scatter correction method for CBCT using an interlacing-slit plate (ISP) is carried out for convenient practice. Firstly, a Gaussian filtering method is proposed to compensate the missing data of the inner scatter image, and simultaneously avoid too-large values of calculated inner scatter and smooth the inner scatter field. Secondly, an interlacing-slit scan without detector gain correction is carried out to enhance the practicality and convenience of the scatter correction method. Finally, a denoising step for scatter-corrected projection images is added in the process flow to control the noise amplification The experimental results show that the improved method can not only make the scatter correction more robust and convenient, but also achieve a good quality of scatter-corrected slice images. Supported by National Science and Technology Major Project of the Ministry of Industry and Information Technology of China (2012ZX04007021), Aeronautical Science Fund of China (2014ZE53059), and Fundamental Research Funds for Central Universities of China (3102014KYJD022)

  10. Influence of the ARC patterning method and annealing on the contact adhesion of Ni/Cu-plated solar cells

    NASA Astrophysics Data System (ADS)

    Baik, Jong Wook; Lee, Sang Hee; Lee, Doo Won; Lee, Soo Hong

    2016-05-01

    Ni/Cu two-step plating is a promising metallization technique because low contact resistance and improved contact adhesion can be achieved after the Ni annealing process. Also, narrow fingers, which are required for high-efficiency solar cells, can be formed by plating. However, the reliability of contact adhesion is still considered one obstacle to industrializing solar cells with plated metal contacts. In this experiment, the influence of ARC opening methods on plated contact adhesion was investigated because the roughnesses of the Si surfaces produced by using pico-second laser ablation and photolithography may be different. Also, the annealing process was conducted before and after plating Cu/Ag metal stacks. The sequence of the annealing can be significant for efficient production because plating is a wet process while annealing is a dry process. The contact adhesion was measured by using a peel-off test. The test was conducted on a 1.5-mm-wide by a 60 ~ 70- mm-long bus bar area. A 3.2-N/mm adhesion force was recorded as a highest average value along the bus bar.

  11. [Method to Calculate the Yield Load of Bone Plate in Four-point Bending Test].

    PubMed

    Jia, Xiaohang; Zhou, Jun; Ma, Jun; Wen, Yan

    2015-09-01

    This paper developed a calculation method to acquire the yield load P of bone plate during four-point bending test. This method is based on the displacement--force (δ-F) curve function f(M)(δ) obtained from the test, each slope of the curve was calculated using piecewise smooth function and the line segment in f(M)(δ) elastic deformation area was searched by setting the minimum slope T. Slope S was obtained through linear fit so as to build parallel displacement function f(L)(δ). Then, approximating intersection point of f(M)(δ) and f(L)(δ) was obtained through linear interpolation. Thus, yield load P was acquired. The method in the paper was loyal to YY/T 0342-2002 regulation and was liable to program calculation. The calculating process was nothing to do with whether the initial point during the test was preloaded or unloaded, and there was no need to correct the original point. In addition, T was set in an ideal fitting level guaranteed by the fitting coefficient of determination R2, and thus S was very close to the real value, and P was with a high accuracy.

  12. The Surface-Tension Method of Visually Inspecting Honeycomb-Core Sandwich Plates

    NASA Technical Reports Server (NTRS)

    Katzoff, Samuel

    1960-01-01

    When one face of a metal-honeycomb-core sandwich plate is heated or cooled relative to the other, heat transfer through the core causes the temperature on each face at the lines of contact with the core to be slightly different from that on the rest of the face. If a thin liquid film is applied to the face, the variation of surface tension with temperature causes the liquid to move from warmer to cooler areas and thus to develop a pattern corresponding to the temperature pattern on the face. Irregularities in the pattern identify the locations where the core is not adequately bonded to the face sheet. The pattern is easily observed when a fluorescent liquid is used and illumination is by means of ultraviolet light. Observation in ordinary light is also possible when a very deeply colored liquid is used. A method based on the use of a thermographic phosphor to observe the temperature pattern was found to be less sensitive than the surface-tension method. A sublimation method was found to be not only less sensitive but also far more troublesome.

  13. Methods for testing Zernike phase plates and a report on silicon-based phase plates with reduced charging and improved ageing characteristics.

    PubMed

    Marko, Michael; Meng, Xing; Hsieh, Chyongere; Roussie, James; Striemer, Christopher

    2013-11-01

    Imaging with Zernike phase plates is increasingly being used in cryo-TEM tomography and cryo-EM single-particle applications. However, rapid ageing of the phase plates, together with the cost and effort in producing them, present serious obstacles to widespread adoption. We are experimenting with phase plates based on silicon chips that have thin windows; such phase plates could be mass-produced and made available at moderate cost. The windows are coated with conductive layers to reduce charging, and this considerably extends the useful life of the phase plates compared to traditional pure-carbon phase plates. However, a compromise must be reached between robustness and transmission through the phase-plate film. Details are given on testing phase-plate performance by means of imaging an amorphous thin film and evaluating the power spectra of the images.

  14. Methods for testing Zernike phase plates and a report on silicon-based phase plates with reduced charging and improved ageing characteristics

    PubMed Central

    Marko, Michael; Meng, Xing; Hsieh, Chyongere; Roussie, James; Striemer, Christopher

    2013-01-01

    Imaging with Zernike phase plates is increasingly being used in cryo-TEM tomography and cryo-EM single-particle applications. However, rapid ageing of the phase plates, together with the cost and effort in producing them, present serious obstacles to widespread adoption. We are experimenting with phase plates based on silicon chips that have thin windows; such phase plates could be mass-produced and made available at moderate cost. The windows are coated with conductive layers to reduce charging, and this considerably extends the useful life of the phase plates compared to traditional pure-carbon phase plates. However, a compromise must be reached between robustness and transmission through the phase-plate film. Details are given on testing phase-plate performance by means of imaging an amorphous thin film and evaluating the power spectra of the images. PMID:23994351

  15. COMPARISON OF THE RECOVERIES OF ESCHERICHIA COLI AND TOTAL COLIFORMS FROM DRINKING WATER BY THE MI AGAR METHOD AND THE U.S. ENVIRONMENTAL PROTECTION AGENCY-APPROVED MEMBRANE FILTER METHOD

    EPA Science Inventory

    Drinking water regulations under the Final Coliform Rule require that total coliform-positive drinking water samples be examined for the presence of Escherichia coli or fecal coliforms. The current U.S. Environmental Protection Agency-approved membrane filter (MF) method for E. c...

  16. A method for high throughput determination of viable bacteria cell counts in 96-well plates

    PubMed Central

    2012-01-01

    Background There are several methods for quantitating bacterial cells, each with advantages and disadvantages. The most common method is bacterial plating, which has the advantage of allowing live cell assessment through colony forming unit (CFU) counts but is not well suited for high throughput screening (HTS). On the other hand, spectrophotometry is adaptable to HTS applications but does not differentiate between dead and living bacteria and has low sensitivity. Results Here, we report a bacterial cell counting method termed Start Growth Time (SGT) that allows rapid and serial quantification of the absolute or relative number of live cells in a bacterial culture in a high throughput manner. We combined the methodology of quantitative polymerase chain reaction (qPCR) calculations with a previously described qualitative method of bacterial growth determination to develop an improved quantitative method. We show that SGT detects only live bacteria and is sensitive enough to differentiate between 40 and 400 cells/mL. SGT is based on the re-growth time required by a growing cell culture to reach a threshold, and the notion that this time is proportional to the number of cells in the initial inoculum. We show several applications of SGT, including assessment of antibiotic effects on cell viability and determination of an antibiotic tolerant subpopulation fraction within a cell population. SGT results do not differ significantly from results obtained by CFU counts. Conclusion SGT is a relatively quick, highly sensitive, reproducible and non-laborious method that can be used in HTS settings to longitudinally assess live cells in bacterial cell cultures. PMID:23148795

  17. Enumeration of total yeasts and molds in foods by the SimPlate Yeast and Mold-Color Indicator method and conventional culture methods: collaborative study.

    PubMed

    Feldsine, Philip T; Lienau, Andrew H; Leung, Stephanie C; Mui, Linda A

    2003-01-01

    The relative effectiveness of the SimPlate Yeast and Mold-Color Indicator method (Y&M-CI) was compared to the U.S. Food and Drug Administration's (FDA) Bacteriological Analytical Manual (BAM) method and the proposed International Organization for Standardization (ISO) method, ISO/CD 21527, for enumerating yeasts and molds in foods. Test portions were prepared and incubated according to the conditions stated in both the BAM and ISO methods. Six food types were analyzed: frozen corn dogs, nut meats, frozen fruits, cake mix, cereal, and fresh cheese. Nut meats, frozen fruits, and fresh cheese were naturally contaminated. All other foods were artificially contaminated with either a yeast or mold. Seventeen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery between the SimPlate method and the 2 corresponding reference methods. Moreover, mean log counts between the 2 reference methods were also very similar. The repeatability (Sr) and reproducibility (SR) standard deviations were comparable between the 3 method comparisons. These results indicate that the BAM method and the SimPlate method are equivalent for enumerating yeast and mold populations in foods. Similarly, the SimPlate method is comparable to the proposed ISO method when test portions are prepared and incubated as defined in the proposed ISO method.

  18. Dry rehydratable film method for rapid enumeration of coliforms in foods (3M Petrifilm Rapid Coliform Count plate): collaborative study.

    PubMed

    Kinneberg, Karen M; Lindberg, Kathryn G

    2002-01-01

    A rehydratable dry-film plating method for coliforms in foods, the 3M Petrifilm Rapid Coliform Count plate method, was compared with the U.S. Food and Drug Administration's Bacteriological Analytical Manual method for nondairy foods and the American Public Health Association's Standard Methods for the Examination of Dairy Products (SMEDP) method for dairy foods. Six food types, vanilla ice cream, cheddar cheese, fresh refrigerated uncooked pasta, wheat flour, prepared frozen macaroni and cheese, and frozen hash browns, were analyzed for coliforms by 11 collaborating laboratories. For each food product tested, the collaborators received 8 blind samples consisting of a control sample and 3 levels of inoculated sample, each in duplicate. The mean log counts for the methods were comparable. The repeatability and reproducibility variances of the Petrifilm Rapid Coliform Count method at 14 and 24 h were not significantly different from those of the standard methods.

  19. Comparison of sorbitol MacConkey and hemorrhagic coli agars for recovery of Escherichia coli O157:H7 from brie, ice cream, and whole milk.

    PubMed

    Hammack, T S; Feng, P; Amaguaña, R M; June, G A; Sherrod, P S; Andrews, W H

    1997-01-01

    The relative efficacies of hemorrhagic coli (HC) agar and several formulations of sorbitol MacConkey (SorMac) agar, with and without 0.1% (w/v) 4-methyllumbelliferyl-beta-D-glucuronide (MUG), in recovering unstressed and heat-stressed Escherichia coli O157:H7 from Brie cheese, ice cream, and whole milk were determined. Recovery of unstressed E. coli O157:H7 was determined quantitatively by spread-plating diluted samples onto different agars and performing plate counts. Recovery of stressed E. coli O157:H7 was determined qualitatively by enriching samples in modified trypticase soy broth, streaking the incubated enrichments, and isolating E. coli O157:H7 colonies from the agars. HC agar and the SorMac agar formulations did not differ significantly in their ability to recover unstressed E. coli O157:H7 from ice cream and whole milk; however, HC agar recovered significantly more unstressed E. coli O157:H7 from Brie cheese than did the SorMac agar formulations. Bacteriological Analytical Manual and Oxoid SorMac agar formulations made from individual ingredients, did not differ significantly in recovering unstressed E. coli O157:H7 from Brie cheese. The efficiency of the commercially available Oxoid SorMac agar could not be determined because of overgrowth by indigenous microflora. HC and SorMac agars did not differ significantly in recovering stressed E. coli O157:H7 from Brie cheese, ice cream, and whole milk. MUG had no apparent effect on recovery of either stressed or unstressed E. coli O157:H7 from the dairy foods examined.

  20. Ultrasonic backscatter coefficients for weakly scattering, agar spheres in agar phantoms

    PubMed Central

    King, Michael R.; Anderson, Janelle J.; Herd, Maria-Teresa; Ma, Darryl; Haak, Alexander; Wirtzfeld, Lauren A.; Madsen, Ernest L.; Zagzebski, James A.; Oelze, Michael L.; Hall, Timothy J.; O’Brien, William D.

    2010-01-01

    Applicability of ultrasound phantoms to biological tissue has been limited because most phantoms have generally used strong scatterers. The objective was to develop very weakly scattering phantoms, whose acoustic scattering properties are likely closer to those of tissues and then compare theoretical simulations and experimental backscatter coefficient (BSC) results. The phantoms consisted of agar spheres of various diameters (nominally between 90 and 212 μm), containing ultrafiltered milk, suspended in an agar background. BSC estimates were performed at two institutions over the frequency range 1–13 MHz, and compared to three models. Excellent agreement was shown between the two laboratory results as well as with the three models. PMID:20707460

  1. Differential specificity of selective culture media for enumeration of pathogenic vibrios: advantages and limitations of multi-plating methods.

    PubMed

    Nigro, Olivia D; Steward, Grieg F

    2015-04-01

    Plating environmental samples on vibrio-selective chromogenic media is a commonly used technique that allows one to quickly estimate concentrations of putative vibrio pathogens or to isolate them for further study. Although this approach is convenient, its usefulness depends directly on how well the procedure selects against false positives. We tested whether a chromogenic medium, CHROMagar Vibrio (CaV), used alone (single-plating) or in combination (double-plating) with a traditional medium thiosulfate-citrate-bile-salts (TCBS), could improve the discrimination among three pathogenic vibrio species (Vibrio cholerae, Vibrio parahaemolyticus, and Vibrio vulnificus) and thereby decrease the number of false-positive colonies that must be screened by molecular methods. Assays were conducted on water samples from two estuarine environments (one subtropical, one tropical) in a variety of seasonal conditions. The results of the double-plating method were confirmed by PCR and 16S rRNA sequencing. Our data indicate that there is no significant difference in the false-positive rate between CaV and TCBS when using a single-plating technique, but determining color changes on the two media sequentially (double-plating) reduced the rate of false positive identification in most cases. The improvement achieved was about two-fold on average, but varied greatly (from 0- to 5-fold) and depended on the sampling time and location. The double-plating method was most effective for V. vulnificus in warm months, when overall V. vulnificus abundance is high (false positive rates as low as 2%, n=178). Similar results were obtained for V. cholerae (minimum false positive rate of 16%, n=146). In contrast, the false positive rate for V. parahaemolyticus was always high (minimum of 59%, n=109). Sequence analysis of false-positive isolates indicated that the majority of confounding isolates are from the Vibrionaceae family, however, members of distantly related bacterial groups were also able to

  2. A Simple Method for Closure of Urethrocutaneous Fistula after Tubularized Incised Plate Repair: Preliminary Results

    PubMed Central

    Shirazi, Mehdi; Ariafar, Ali; Babaei, Amir Hossein; Ashrafzadeh, Abdosamad; Adib, Ali

    2016-01-01

    Background Urethrocutaneous fistula (UCF) is the most prevalent complication after hypospadias repair surgery. Many methods have been developed for UCF correction, and the best technique for UCF repair is determined based on the size, location, and number of fistulas, as well as the status of the surrounding skin. Objectives In this study, we introduced and evaluated a simple method for UCF correction after tubularized incised plate (TIP) repair. Methods This clinical study was conducted on children with UCFs ≤ 4 mm that developed after TIP surgery for hypospadias repair. The skin was incised around the fistula and the tract was released from the surrounding tissues and the dartos fascia, then ligated with 5 - 0 polydioxanone (PDS) sutures. The dartos fascia, as the second layer, was covered on the fistula tract with PDS thread (gauge 5 - 0) by the continuous suture method. The skin was closed with 6 - 0 Vicryl sutures. After six months of follow-up, surgical outcomes were evaluated based on fistula relapse and other complications. Results After six months, relapse occurred in only one patient, a six-year-old boy with a single 4-mm distal opening, who had undergone no previous fistula repairs. Therefore, in 97.5% of the cases, relapse was non-existent. Other complications, such as urethral stenosis, intraurethral obstruction, and epidermal inclusion cysts, were not seen in the other patients during the six-month follow-up period. Conclusions This repair method, which is simple, rapid, and easily learned, is highly applicable, with a high success rate for the closure of UCFs measuring up to 4 mm in any location. PMID:27933278

  3. Continuous degradation of maltose: improvement in stability and catalytic properties of maltase (α-glucosidase) through immobilization using agar-agar gel as a support.

    PubMed

    Nawaz, Muhammad Asif; Karim, Asad; Aman, Afsheen; Marchetti, Roberta; Qader, Shah Ali Ul; Molinaro, Antonio

    2015-04-01

    Maltose degrading enzyme was immobilized within agar-agar support via entrapment method due to its industrial utilization. The maximum immobilization efficiency (82.77%) was achieved using 4.0% agar-agar keeping the diameter of bead up to 3.0 mm. The matrix entrapment showed maximum catalytic activity at pH 7.0 and temperature 65 °C. Substrate saturation kinetics showed that the K m of immobilized enzyme increased from 1.717 to 2.117 mM ml(-1) where as Vmax decreased from 8,411 to 7,450 U ml(-1 )min(-1) as compared to free enzyme. The immobilization significantly increased the stability of maltase against various temperatures and immobilized maltase retain 100% of its original activity after 2 h at 50 °C, whereas the free maltase only showed 60% residual activity under same condition. The reusability of entrapped maltase showed activity up to 12 cycles and retained 50% of activity even after 5th cycle. Storage stability of agar entrapped maltase retain 73% of its initial activity even after 2 months when stored at 30 °C while free enzyme showed only 37% activity at same storage conditions.

  4. Modal vibration analysis of a metal plate by using a laser vibrometer and the POD method

    NASA Astrophysics Data System (ADS)

    Moreno, D.; Barrientos, B.; Pérez-López, C.; Mendoza Santoyo, F.

    2005-06-01

    The proper orthogonal decomposition (POD), also known as Karhunen-Loève expansion, is applied to the modal vibration analysis of a metal plate. The metal plate was subject to vibrations with an electrodynamical shaker in a range of frequencies from 100 to 5000 Hz. The data were obtained from the measurements with a laser vibrometer. The plate vibration measurements were used to calculate the eigenfunctions and the eigenvalues. It was found that a large fraction of the total energy of the vibrations is contained within the first four POD modes. The essential features of the vibrations are thus described by only the first four eigenfunctions.

  5. Evaluation of ISO 10272:2006 standard versus alternative enrichment and plating combinations for enumeration and detection of Campylobacter in chicken meat.

    PubMed

    Habib, Ihab; Uyttendaele, Mieke; De Zutter, Lieven

    2011-09-01

    In the present study, we evaluate the recommended ISO 10272:2006 versus alternative procedures for Campylobacter enumeration and enrichment in naturally contaminated chicken meat samples (n = 49). Three enrichment media were evaluated; Bolton broth, Preston broth and CampyFood broth(®) (bioMérieux SA, Marcy l'Etoile, France). In addition, three selective plating agars were compared; modified charcoal cefoperazone deoxycholate agar (mCCDA), CampyFood agar(®) (CFA; bioMérieux SA) and Brilliance CampyCount agar(®) (BCC; Oxoid, Basingstoke, England). Direct plating on CFA provided the highest number of Campylobacter positive samples (17/49); however this was not statistically different (P > 0.05) from numbers of positive samples recovered by direct plating on mCCDA (15/49) or BCC agars (14/49). Also, there was no significant difference between Campylobacter counts on the three compared media (P > 0.05). The coloured colonies of Campylobacter on CFA and BCC were easier to record and count than those on mCCDA. Enrichment of chicken meat samples in Bolton broth for 48 h and subsequent plating on CFA provided significantly higher (P < 0.05) Campylobacter detection compared to the other broth-agar combinations. Enrichment in Preston broth for 24 h followed by plating on mCCDA gave a higher number of positive samples (20/49) than 48 h enrichment in Bolton broth and plating on mCCDA (15/49). Enrichment in Bolton broth for 48 h followed by plating on CFA recovered 35% of samples below the limit for quantifications (<10 CFU/g, n = 34), as identified by direct plating on mCCDA. Compared to the current ISO method, some alternative combinations of enrichment and agar media could provide significantly better detection and enumeration of Campylobacter in chicken meat.

  6. Multicenter Study of Method-Dependent Epidemiological Cutoff Values for Detection of Resistance in Candida spp. and Aspergillus spp. to Amphotericin B and Echinocandins for the Etest Agar Diffusion Method.

    PubMed

    Espinel-Ingroff, A; Arendrup, M; Cantón, E; Cordoba, S; Dannaoui, E; García-Rodríguez, J; Gonzalez, G M; Govender, N P; Martin-Mazuelos, E; Lackner, M; Lass-Flörl, C; Linares Sicilia, M J; Rodriguez-Iglesias, M A; Pelaez, T; Shields, R K; Garcia-Effron, G; Guinea, J; Sanguinetti, M; Turnidge, J

    2017-01-01

    Method-dependent Etest epidemiological cutoff values (ECVs) are not available for susceptibility testing of either Candida or Aspergillus species with amphotericin B or echinocandins. In addition, reference caspofungin MICs for Candida spp. are unreliable. Candida and Aspergillus species wild-type (WT) Etest MIC distributions (microorganisms in a species-drug combination with no detectable phenotypic resistance) were established for 4,341 Candida albicans, 113 C. dubliniensis, 1,683 C. glabrata species complex (SC), 709 C. krusei, 767 C. parapsilosis SC, 796 C. tropicalis, 1,637 Aspergillus fumigatus SC, 238 A. flavus SC, 321 A. niger SC, and 247 A. terreus SC isolates. Etest MICs from 15 laboratories (in Argentina, Europe, Mexico, South Africa, and the United States) were pooled to establish Etest ECVs. Anidulafungin, caspofungin, micafungin, and amphotericin B ECVs (in micrograms per milliliter) encompassing ≥97.5% of the statistically modeled population were 0.016, 0.5, 0.03, and 1 for C. albicans; 0.03, 1, 0.03, and 2 for C. glabrata SC; 0.06, 1, 0.25, and 4 for C. krusei; 8, 4, 2, and 2 for C. parapsilosis SC; and 0.03, 1, 0.12, and 2 for C. tropicalis The amphotericin B ECV was 0.25 μg/ml for C. dubliniensis and 2, 8, 2, and 16 μg/ml for the complexes of A. fumigatus, A. flavus, A. niger, and A. terreus, respectively. While anidulafungin Etest ECVs classified 92% of the Candida fks mutants evaluated as non-WT, the performance was lower for caspofungin (75%) and micafungin (84%) cutoffs. Finally, although anidulafungin (as an echinocandin surrogate susceptibility marker) and amphotericin B ECVs should identify Candida and Aspergillus isolates with reduced susceptibility to these agents using the Etest, these ECVs will not categorize a fungal isolate as susceptible or resistant, as breakpoints do.

  7. Biological treatment of textile dyes by agar-agar immobilized consortium in a packed bed reactor.

    PubMed

    Patel, Yogesh; Gupte, Akshaya

    2015-03-01

    The decolorization of Acid Maroon V was investigated using bacterial consortium EDPA containing Enterobacter dissolvens AGYP1 and Pseudomonas aeruginosa AGYP2 immobilized in different entrapment matrices. The consortium displayed 96% removal of dye (100 mg/l) within 6 h when immobilized in agar-agar. Under optimum concentrations of agar-agar (3.0% w/v) and cell biomass (0.9 g% w/v), the consortium displayed decolorization for 18 successive batches of Acid Maroon V and also decolorized 14 other different textile dyes. A packed bed reactor under batch mode showed 89% decolorization of dye after 56 repetitive cycles. Under continuous flow mode, maximum color removal was achieved with bed length of 36 cm, hydraulic retention time of 2.66 h, and dye concentration of 100 mg/l. Additionally, the reactor decolorized relatively higher concentrations (100-2000 mg/l) of dye. The synthetic dye wastewater containing five textile dyes was decolorized 92% with 62% COD reduction using an immobilized consortium.

  8. A new method to assess temporal features of gait initiation with a single force plate.

    PubMed

    Moineau, Bastien; Boisgontier, Matthieu P; Barbieri, Guillaume; Nougier, Vincent

    2014-01-01

    The aim of this study was to investigate whether time of toe-off and heel-contact during gait initiation could be assessed with a single force plate. Twenty subjects performed ten self-paced gait initiations and seven other subjects performed ten gait initiations in four new conditions (slow, fast, obstacle and splint). Several force-plate parameters were measured with a single force plate, and actual toe-off and heel-contact were assessed with a motion analysis system. Results showed strong temporal correlations and closeness (r=.86-.99, mean error=3-86 ms) between two force-plate parameters and the kinematics events (toe-off and heel-contact). These new parameters may be of interest to easily measure duration of anticipatory postural adjustments and swing phase during clinical assessments.

  9. A colorimetric method for the measurement of platelet adhesion in microtiter plates.

    PubMed

    Bellavite, P; Andrioli, G; Guzzo, P; Arigliano, P; Chirumbolo, S; Manzato, F; Santonastaso, C

    1994-02-01

    A procedure for the determination of the adhesion of human platelets to protein-coated culture microwells was developed. The number of platelets was quantitated by measuring the activity of acid phosphatase, a platelet enzyme whose activity is stable independently of platelet stimulation and is not released. Isolated and washed platelets were incubated in 96-well microtiter plates with flat-bottom wells that had been precoated with various compounds, including collagen, fibrinogen, human plasma, and human albumin. At the end of incubation (optimal time: 40-60 min), nonadherent platelets were washed out, adherent platelets were solubilized with Triton X-100, and the acid phosphatase activity was measured by using the substrate p-nitrophenyl phosphate. The p-nitrophenol produced was measured with a microplate reader at 405 nm and the percentage of adhesion was calculated with reference to known platelet standards. ADP and thrombin stimulated platelet adhesion in a dose-dependent manner to fibrinogen and human plasma, but not to human albumin. Platelets adhered to collagen even in the absence of stimulants. Simultaneous evaluation of adhesion and aggregation demonstrated that with ADP as stimulus, but not with thrombin, the two platelet responses were dissociated. Microscopic examination of culture wells showed that most of platelets adhered as single cells and not as aggregates. The sensitivity of this method allowed the assay of platelet adhesion by using only 2.5 x 10(5) platelets/well.

  10. Enumeration of bacteria in clinically significant blood cultures in neutropenic and non-neutropenic patients using a pour plate method.

    PubMed

    Rice, P; Spencer, R C

    1991-03-01

    A 3-year review of clinically significant positive blood cultures was undertaken to assess any differences in the blood bacterial count between haematological neutropenic and other non-neutropenic patients. The pour-plate method was used. In Gram-positive infections the pour plate contained colonies in 61% of haematological patients and in 41% of others. In Gram-negative infection the figures were 54% and 25% respectively. The mean numbers of bacteria per ml of blood were increased in haematological patients compared with the others for both groups of organisms.

  11. Group method analysis of magneto-elastico-viscous flow along a semi-infinite flat plate with heat transfer

    NASA Astrophysics Data System (ADS)

    Helal, M. M.; Abd-El-Malek, M. B.

    2005-01-01

    The group theoretic method is applied for solving problem of the flow of an elastico-viscous liquid past an infinite flat plate in the presence of a magnetic field normal to the plate. The application of one-parameter transformation group reduces the number of independent variables, by one, and consequently the system of governing partial differential equations with boundary conditions reduces to a system of ordinary differential equations with appropriate corresponding conditions. Numerical solution of the velocity field and heat transfer have been obtained. The effect of the magnetic parameter M on velocity field, shear stress, temperature fields and heat transfer has been discussed.

  12. Electroless plating of PVC plastic through new surface modification method applying a semi-IPN hydrogel film

    NASA Astrophysics Data System (ADS)

    Wang, Ming-Qiu; Yan, Jun; Du, Shi-Guo; Li, Hong-Guang

    2013-07-01

    A novel palladium-free surface activation process for electroless nickel plating was developed. This method applied a semi-Interpenetrating Polymer Network (semi-IPN) hydrogel film to modify the poly(vinyl chloride) (PVC) surface by chemical bonds. The activation process involved the formation of semi-IPN hydrogel film on the PVC surface and the immobilization of catalyst for electroless plating linking to the pretreated substrate via Nsbnd Ni chemical bond. The hydrogel layer was used as the chemisorption sites for nickel ions, and the catalyst could initiate the subsequent electroless nickel plating onto the PVC surface. Finally, a Ni-P layer was deposited on the nickel-activated PVC substrate by electroless plating technique. The composition and morphology of nickel-plated PVC foils were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). The results of SEM and XRD show that a compact and continuous Ni-P layer with amorphous nickel phase is formed on the PVC surface. EDS shows that the content of the nickel and the phosphorus in the deposits is 89.4 wt.% and 10.6 wt.%, respectively.

  13. The construction of airfoil pressure models by the plate method: Achievements, current research, technology development and potential applications

    NASA Technical Reports Server (NTRS)

    Lawing, P. L.

    1985-01-01

    A method of constructing airfoils by inscribing pressure channels on the face of opposing plates, bonding them together to form one plate with integral channels, and contour machining this plate to form an airfoil model is described. The research and development program to develop the bonding technology is described as well as the construction and testing of an airfoil model. Sample aerodynamic data sets are presented and discussed. Also, work currently under way to produce thin airfoils with camber is presented. Samples of the aft section of a 6 percent airfoil with complete pressure instrumentation including the trailing edge are pictured and described. This technique is particularly useful in fabricating models for transonic cryogenic testing, but it should find application in a wide ange of model construction projects, as well as the fabrication of fuel injectors, space hardware, and other applications requiring advanced bonding technology and intricate fluid passages.

  14. Mean grain size detection of DP590 steel plate using a corrected method with electromagnetic acoustic resonance.

    PubMed

    Wang, Bin; Wang, Xiaokai; Hua, Lin; Li, Juanjuan; Xiang, Qing

    2017-04-01

    Electromagnetic acoustic resonance (EMAR) is a considerable method to determine the mean grain size of the metal material with a high precision. The basic ultrasonic attenuation theory used for the mean grain size detection of EMAR is come from the single phase theory. In this paper, the EMAR testing was carried out based on the ultrasonic attenuation theory. The detection results show that the double peaks phenomenon occurs in the EMAR testing of DP590 steel plate. The dual phase structure of DP590 steel is the inducement of the double peaks phenomenon in the EMAR testing. In reaction to the phenomenon, a corrected method with EMAR was put forward to detect the mean grain size of dual phase steel. Compared with the traditional attenuation evaluation method and the uncorrected method with EMAR, the corrected method with EMAR shows great effectiveness and superiority for the mean grain size detection of DP590 steel plate.

  15. Comparison of two optical-density-based methods and a plate count method for estimation of growth parameters of Bacillus cereus.

    PubMed

    Biesta-Peters, Elisabeth G; Reij, Martine W; Joosten, Han; Gorris, Leon G M; Zwietering, Marcel H

    2010-03-01

    Quantitative microbiological models predicting proliferation of microorganisms relevant for food safety and/or food stability are useful tools to limit the need for generation of biological data through challenge testing and shelf-life testing. The use of these models requires quick and reliable methods for the generation of growth data and estimation of growth parameters. Growth parameter estimation can be achieved using methods based on plate counting and methods based on measuring the optical density. This research compares the plate count method with two optical density methods, namely, the 2-fold dilution (2FD) method and the relative rate to detection (RRD) method. For model organism Bacillus cereus F4810/72, the plate count method and both optical density methods gave comparable estimates for key growth parameters. Values for the maximum specific growth rate (mu(max)) derived by the 2FD method and by the RRD method were of the same order of magnitude, but some marked differences between the two approaches were apparent. Whereas the 2FD method allowed the derivation of values for lag time (lambda) from the data, this was not possible with the RRD method. However, the RRD method gave many more data points per experiment and also gave more data points close to the growth boundary. This research shows that all three proposed methods can be used for parameter estimation but that the choice of method depends on the objectives of the research.

  16. Improving agar electrospinnability with choline-based deep eutectic solvents.

    PubMed

    Sousa, Ana M M; Souza, Hiléia K S; Uknalis, Joseph; Liu, Shih-Chuan; Gonçalves, Maria P; Liu, LinShu

    2015-09-01

    Very recently our group has produced novel agar-based fibers by an electrospinning technique using water as solvent and polyvinyl alcohol (PVA) as co-blending polymer. Here, we tested the deep eutectic solvent (DES), (2-hydroxyethyl)trimethylammonium chloride/urea prepared at 1:2 molar ratio, as an alternative solvent medium for agar electrospinning. The electrospun materials were collected with an ethanol bath adapted to a previous electrospinning set-up. One weight percent agar-in-DES showed improved viscoelasticity and hence, spinnability, when compared to 1 wt% agar-in-water and pure agar nanofibers were successfully electrospun if working above the temperature of sol-gel transition (∼80 °C). By changing the solvent medium we decreased the PVA concentration (5 wt% starting solution) and successfully produced composite fibers with high agar contents (50/50 agar/PVA). Best composite fibers were formed with the 50/50 and 30/70 agar/PVA solutions. These fibers were mechanically resistant, showed tailorable surface roughness and diverse size distributions, with most of the diameters falling in the sub-micron range. Both nano and micro forms of agar fibers (used separately or combined) may have potential for the design of new and highly functional agar-based materials.

  17. Automatic Surface Inoculation of Agar Trays1

    PubMed Central

    Wilkins, Judd R.; Mills, Stacey M.; Boykin, Elizabeth H.

    1972-01-01

    A machine is described which automatically inoculates a plastic tray containing agar media with a culture by use of either a conventional inoculating loop or a cotton swab. Isolated colonies were obtained with an inoculating loop when a heavy inoculum (109 cells/ml) was used or with a cotton swab when a light inoculum (ca. 104 cells/ml) was used. Trays containing combinations of differential or selective media were used to (i) separate mixtures of gram-positive and gram-negative bacteria, (ii) facilitate isolation of organisms from clinical specimens, and (iii) compare colony growth characteristics of pure cultures. The design of the machine is simple, it is easy to use, and it relieves the operator from the manual task of streaking cultures. Images PMID:16349943

  18. Poisoning with brown fly agaric, Amanita regalis.

    PubMed

    Elonen, E; Tarssanen, L; Härkönen, M

    1979-01-01

    Three patients ate different amounts of a common northern mushroom, brown fly agaric, Amanita regalis. All of them believed they had eaten delicious parasol mushrooms, Macrolepiota procera. The symptoms of poisoning began 1--2 hours after ingestion of the mushrooms. All the patients had marked gastrointestinal symptoms: nausea and heavy vomiting. Two had central nervous system manifestations and cholinergic symptoms: hallucinations, confusion, or loss of consciousness as well as copious salivation, or sweating. All patients recovered within 4--24 hours without any damage to liver, kidneys or central nervous system. It seems that cooking the mushrooms does not completely neutralize the toxic agents of Amanita regalis. The analysis of fried mushrooms shows that it may be possible to identify mushrooms reliably from the remains of a meal.

  19. The Optimizing Conditions by Taguchi Method for Fabricating Semi-Solid Al-Zn-Mg Alloy Slurry by Cooling Plate Method

    NASA Astrophysics Data System (ADS)

    Shim, Sung-Yong; Park, Hyung-Won; Jeong, In-Sang; Lim, Su-Gun

    In order to optimize the condition for the semi-solid Al-Zn-Mg aluminium alloy fabricated by cooling plate method, the Taguchi design was used. The cooling plate method effectively separating the grains formed from the mold wall can be used to form a semi-solid material by flowing molten metal over an inclined Cu plate and casting in a mold for the near-net shape component. In Taguchi's design method, the higher signal vs noise (S/N) ratio the better. Therefore, the manufacturing conditions were arranged as a table of orthogonal arrays (L9(34)), and the influence of two factors, pouring temperature and cooling plate angle, was examined. From the observed microstructures, the grain size and aspect ratio were measured by image analyzer. The results indicated that the pouring temperature exerts the main effect on the spherical microstructures since the S/N ratio, which is the sensibility of the surrounding environment, was the highest. The optimum condition for the Al-Zn-Mg alloy was a cooling plate angle of 40° and a pouring temperature of 680°C. The grain size and aspect ratio were 70 μm and 1.3, respectively.

  20. A plate method for rapid screening of Ketogulonicigenium vulgare mutants for enhanced 2-keto-l-gulonic acid production.

    PubMed

    Yang, Weichao; Han, Litao; Mandlaa, Mandlaa; Zhang, Haihong; Zhang, Zhongze; Xu, Hui

    2017-02-21

    A new plate method was developed for rapid screening of Ketogulonicigenium vulgare mutants overproducing 2-keto-l-gulonic acid (2-KLG). The screening methodology took the advantage of the acidity caused by 2-KLG, which changes the color of bromothymol blue (pH indicator) from blue to yellow. Using the proposed method, a mutant, K. vulgare 65, was selected from 20,000 colonies produced by a strain subjected to spaceflight mutagenesis. When co-cultured with Bacillus megaterium 2980 in 20-L fermenters, K. vulgare 65 showed a high conversion rate (94.45%) of l-sorbose to 2-KLG. In contrast to the traditional screening method, this one significantly improved the frequency of obtaining positive mutants. The proposed plate screening method is cost-effective and easy to run and is thus useful for the isolation and screening of K. vulgare mutants overproducing 2-KLG.

  1. A high-throughput microtiter plate based method for the determination of peracetic acid and hydrogen peroxide.

    PubMed

    Putt, Karson S; Pugh, Randall B

    2013-01-01

    Peracetic acid is gaining usage in numerous industries who have found a myriad of uses for its antimicrobial activity. However, rapid high throughput quantitation methods for peracetic acid and hydrogen peroxide are lacking. Herein, we describe the development of a high-throughput microtiter plate based assay based upon the well known and trusted titration chemical reactions. The adaptation of these titration chemistries to rapid plate based absorbance methods for the sequential determination of hydrogen peroxide specifically and the total amount of peroxides present in solution are described. The results of these methods were compared to those of a standard titration and found to be in good agreement. Additionally, the utility of the developed method is demonstrated through the generation of degradation curves of both peracetic acid and hydrogen peroxide in a mixed solution.

  2. Application of the HHT Method to the Non-contact Thickness Measurement of an Axially Moving Thin Plate

    NASA Astrophysics Data System (ADS)

    Wu, Yangfang; Lu, Qianqian; Xia, Chunlin; Ding, Fan

    2016-06-01

    Non-contact thickness measuring systems can be found in a wide spectrum of technologies. In this paper, Hilbert-Huang transform method is used to analyze the real time signals of a measuring system which includes two round conveyor strings carrying a thin plate, a solar wafer as a sample under test. The vibrations of moving strings and the plate, which are sensitive to moving speed and initial tension in the string, are introduced briefly; the relevant analyses should be helpful for the system design. Using EMD-based time-domain filtering and complementary method, thickness variations and error bands are estimated for different cases. The results show that HHT method as an adaptive time-frequency method, should be potential in measurement engineering applications.

  3. Evaluation of a Test Article in the Salmonella typhimurium/Ecscherichia coli Plate Incorporation Mutation Assay in the Presence and Absence of Induced Rat Liver S-9. Test Article - Diethylene triamine trinitrate (DETN)

    DTIC Science & Technology

    2010-02-25

    the culture is required in order to be metabolized prior to plating . The Pre-Incubation method of treatment is perfonned at the request ofthe...Kalamazoo, Michigan. CULTURE CONDITIONS The cells were grown in Oxoid Nutrient Broth No.2 (Oxoid LTD, Hampshire, England) in a shaker incubator... aseptically placed in the center of the agar overlay. Ten ilL of a 1.0 mg/mL crystal violet solution was then added to the disc. The plates were

  4. Enumeration of micro-organisms in food: a comparative study of five methods.

    PubMed Central

    Kramer, J. M.; Gilbert, R. J.

    1978-01-01

    Five methods for the enumeration of micro-organisms in food (pour plate, surface spread plate, surface drop, agar droplet, and microdilution) were used in parallel to examine 100 samples selected from a wide range of food products. Statistical analyses of the results showed that the regression and correlation coefficients between the methods were highly significant; the lowest correlation coefficient derived for any pair of methods was 0.979. A variation in count between the methods of less than 0.5 log10 cycles was given by 98% of the samples. Analysis of the operation times and material requirements of each method showed that substantial savings in cost, time, space and support labour were achieved with the microdilution and agar droplet techniques as compared with the conventional pour plate and spread plate methods. PMID:690422

  5. Agar Sediment Test for Assessing the Suitability of Organic Waste Streams for Recovering Nutrients by the Aquatic Worm Lumbriculus variegatus

    PubMed Central

    Laarhoven, Bob; Elissen, H. J. H.; Temmink, H.; Buisman, C. J. N.

    2016-01-01

    An agar sediment test was developed to evaluate the suitability of organic waste streams from the food industry for recovering nutrients by the aquatic worm Lumbriculus variegatus (Lv). The effects of agar gel, sand, and food quantities in the sediment test on worm growth, reproduction, and water quality were studied. Agar gel addition ameliorated growth conditions by reducing food hydrolysis and altering sediment structure. Best results for combined reproduction and growth were obtained with 0.6% agar-gel (20 ml), 10 g. fine sand, 40 g. coarse sand, and 105 mg fish food (Tetramin). With agar gel, ingestion and growth is more the result of addition of food in its original quality. Final tests with secondary potato starch sludge and wheat bran demonstrated that this test is appropriate for the comparison of solid feedstuffs and suspended organic waste streams. This test method is expected to be suitable for organic waste studies using other sediment dwelling invertebrates. PMID:26937632

  6. Agar Sediment Test for Assessing the Suitability of Organic Waste Streams for Recovering Nutrients by the Aquatic Worm Lumbriculus variegatus.

    PubMed

    Laarhoven, Bob; Elissen, H J H; Temmink, H; Buisman, C J N

    2016-01-01

    An agar sediment test was developed to evaluate the suitability of organic waste streams from the food industry for recovering nutrients by the aquatic worm Lumbriculus variegatus (Lv). The effects of agar gel, sand, and food quantities in the sediment test on worm growth, reproduction, and water quality were studied. Agar gel addition ameliorated growth conditions by reducing food hydrolysis and altering sediment structure. Best results for combined reproduction and growth were obtained with 0.6% agar-gel (20 ml), 10 g. fine sand, 40 g. coarse sand, and 105 mg fish food (Tetramin). With agar gel, ingestion and growth is more the result of addition of food in its original quality. Final tests with secondary potato starch sludge and wheat bran demonstrated that this test is appropriate for the comparison of solid feedstuffs and suspended organic waste streams. This test method is expected to be suitable for organic waste studies using other sediment dwelling invertebrates.

  7. Modeling of wave propagation in plate structures using three-dimensional spectral element method for damage detection

    NASA Astrophysics Data System (ADS)

    Peng, Haikuo; Meng, Guang; Li, Fucai

    2009-03-01

    This paper presents the application of three-dimensional (3-D) spectral element method (SEM) to wave propagation problems in plate structures for the purpose of damage detection. The excellent characteristic of the SEM is that the mass matrix is diagonal because of the choice of Lagrange interpolation function supported on the Gauss-Lobatto-Legendre (GLL) points in conjunction with the GLL integration rule. Therefore, numerical calculation can be significantly efficient in comparison with the classical finite element method (FEM). By taking advantage of this characteristic, a 3-D spectral finite elements (SFEs)-based model is developed to simulate the wave propagation in plate structures. Lamb waves, propagating in aluminum plates with and without a crack are investigated. Responses from 3-D SFEs- and 2-D SFEs-based models are compared. Different Lamb wave modes are generated using different excitation approaches and, subsequently, characteristics of those modes are analyzed. The results demonstrate that the proposed model can offer efficient and realistic simulation for Lamb wave propagation in plate structures, so as to detect damages in those structures.

  8. Evaluation of CP Chromo Select Agar for the enumeration of Clostridium perfringens from water.

    PubMed

    Manafi, Mammad; Waldherr, Kerstin; Kundi, Michael

    2013-10-01

    The European Directive on drinking water quality has included mCP agar as the reference method for recovering Clostridium perfringens from drinking waters. In the present study, three media (mCP, TSCF and CP Chromo Select Agar) were evaluated for recovery of C. perfringens in different surface water samples. Out of 139 water samples, using a membrane filtration technique, 131 samples (94.2%) were found to be presumptively positive for C. perfringens in at least one of the culture media. Green colored colonies on CP Chromo Select Agar (CCP agar) were counted as presumptive C. perfringens isolates. Out of 483 green colonies on CCP agar, 96.3% (465 strains, indole negative) were identified as C. perfringens, and 15 strains (3.1%) were indole positive and were identified as Clostridium sordellii, Clostridium bifermentans or Clostridium tetani. Only 3 strains (0.6%) gave false positive results and were identified as Clostridium fallax, Clostridium botulinum, and Clostridium tertium. Variance analysis of the data obtained shows statistically no significant differences in the counts obtained between media employed in this work. The mCP method is very onerous for routine screening and bacterial colonies could not be used for further biochemical testing. The colonies on CCP and TSCF were easy to count and subculture for confirmation tests. TSCF detects sulfite-reducing clostridia, including species other than C. perfringens, and in some cases excessive blackening of the agar frustrated counting of the colonies. If the contamination was too high, TSCF did not consistently produce black colonies and as a consequence, the colonies were white and gave false negative results. On the other hand, the identification of typical and atypical colonies isolated from all media demonstrated that CCP agar was the most useful medium for C. perfringens recovery in water samples.

  9. Comparison of plate counts, Petrifilm, dipslides, and adenosine triphosphate bioluminescence for monitoring bacteria in cooling-tower waters.

    PubMed

    Mueller, Sherry A; Anderson, James E; Kim, Byung R; Ball, James C

    2009-04-01

    Effective bacterial control in cooling-tower systems requires accurate and timely methods to count bacteria. Plate-count methods are difficult to implement on-site, because they are time- and labor-intensive and require sterile techniques. Several field-applicable methods (dipslides, Petrifilm, and adenosine triphosphate [ATP] bioluminescence) were compared with the plate count for two sample matrices--phosphate-buffered saline solution containing a pure culture of Pseudomonas fluorescens and cooling-tower water containing an undefined mixed bacterial culture. For the pure culture, (1) counts determined on nutrient agar and plate-count agar (PCA) media and expressed as colony-forming units (CFU) per milliliter were equivalent to those on R2A medium (p = 1.0 and p = 1.0, respectively); (2) Petrifilm counts were not significantly different from R2A plate counts (p = 0.99); (3) the dipslide counts were up to 2 log units higher than R2A plate counts, but this discrepancy was not statistically significant (p = 0.06); and (4) a discernable correlation (r2 = 0.67) existed between ATP readings and plate counts. For cooling-tower water samples (n = 62), (1) bacterial counts using R2A medium were higher (but not significant; p = 0.63) than nutrient agar and significantly higher than tryptone-glucose yeast extract (TGE; p = 0.03) and PCA (p < 0.001); (2) Petrifilm counts were significantly lower than nutrient agar or R2A (p = 0.02 and p < 0.001, respectively), but not statistically different from TGE, PCA, and dipslides (p = 0.55, p = 0.69, and p = 0.91, respectively); (3) the dipslide method yielded bacteria counts 1 to 3 log units lower than nutrient agar and R2A (p < 0.001), but was not significantly different from Petrifilm (p = 0.91), PCA (p = 1.00) or TGE (p = 0.07); (4) the differences between dipslides and the other methods became greater with a 6-day incubation time; and (5) the correlation between ATP readings and plate counts varied from system to system, was poor

  10. A new diagnostic method for separating airborne and structureborne noise radiated by plates with applications for propeller driven aircraft

    NASA Technical Reports Server (NTRS)

    Mcgary, Michael C.

    1988-01-01

    The anticipated application of advanced turboprop propulsion systems is expected to increase the interior noise of future aircraft to unacceptably high levels. The absence of technically and economically feasible noise source-path diagnostic tools has been a prime obstacle in the development of efficient noise control treatments for propeller-driven aircraft. A new diagnostic method that permits the separation and prediction of the fully coherent airborne and structureborne components of the sound radiated by plates or thin shells has been developed. Analytical and experimental studies of the proposed method were performed on an aluminum plate. The results of the study indicate that the proposed method could be used in flight, and has fewer encumbrances than the other diagnostic tools currently available.

  11. Microtiter plate transformation using the LiAc/SS carrier DNA/PEG method.

    PubMed

    Gietz, R Daniel; Schiestl, Robert H

    2007-01-01

    Here, we describe a protocol that has been adapted for the transformation of yeast cells in 96-well microtiter plates. This protocol can be tailored for multiple applications and is suitable for high-throughput applications. It can be completed in 2-3 h, once the yeast cells have been grown depending on the heat shock used.

  12. Characterization of bionanocomposite films prepared with agar and paper-mulberry pulp nanocellulose.

    PubMed

    Reddy, Jeevan Prasad; Rhim, Jong-Whan

    2014-09-22

    Crystallized nanocellulose (CNC) was separated from paper-mulberry (Broussonetia kazinoki Siebold) bast pulp by sulfuric acid hydrolysis method and they were blended with agar to prepare bionanocomposite films. The effect of CNC content (1, 3, 5 and 10 wt% based on agar) on the mechanical, water vapor permeability (WVP), and thermal properties of the nanocomposites were studied. Changes of the cellulose fibers in structure, morphology, crystallinity, and thermal properties of the films were evaluated using FT-IR, TEM, SEM, XRD, and TGA analysis methods. The CNC was composed of fibrous and spherical or elliptic granules of nano-cellulose with sizes of 50-60 nm. Properties of agar film such as mechanical and water vapor barrier properties were improved significantly (p<0.05) by blending with the CNC. The tensile modulus and tensile strength of agar film increased by 40% and 25%, respectively, in the composite film with 5 wt% of CNC, and the WVP of agar film decreased by 25% after formation of nanocomposite with 3 wt% of CNC. The CNC obtained from the paper-mulberry bast pulp can be used as a reinforcing agent for the preparation of bio-nanocomposites, and they have a high potential for the development of completely biodegradable food packaging materials.

  13. Requirements and testing methods for surfaces of metallic bipolar plates for low-temperature PEM fuel cells

    NASA Astrophysics Data System (ADS)

    Jendras, P.; Lötsch, K.; von Unwerth, T.

    2017-03-01

    To reduce emissions and to substitute combustion engines automotive manufacturers, legislature and first users aspire hydrogen fuel cell vehicles. Up to now the focus of research was set on ensuring functionality and increasing durability of fuel cell components. Therefore, expensive materials were used. Contemporary research and development try to substitute these substances by more cost-effective material combinations. The bipolar plate is a key component with the greatest influence on volume and mass of a fuel cell stack and they have to meet complex requirements. They support bending sensitive components of stack, spread reactants over active cell area and form the electrical contact to another cell. Furthermore, bipolar plates dissipate heat of reaction and separate one cell gastight from the other. Consequently, they need a low interfacial contact resistance (ICR) to the gas diffusion layer, high flexural strength, good thermal conductivity and a high durability. To reduce costs stainless steel is a favoured material for bipolar plates in automotive applications. Steel is characterized by good electrical and thermal conductivity but the acid environment requires a high chemical durability against corrosion as well. On the one hand formation of a passivating oxide layer increasing ICR should be inhibited. On the other hand pitting corrosion leading to increased permeation rate may not occur. Therefore, a suitable substrate lamination combination is wanted. In this study material testing methods for bipolar plates are considered.

  14. Experimental modal analysis of an aluminum rectangular plate by use of the slope-assisted BOTDA method

    NASA Astrophysics Data System (ADS)

    Minardo, A.; Coscetta, A.; Pirozzi, S.; Bernini, R.; Zeni, L.

    2013-12-01

    We report an experimental modal analysis of an aluminum rectangular plate (50 cm×30 cm×0.3 cm), carried out by use of a Brillouin optical time-domain analysis (BOTDA) sensor operating in the slope-assisted configuration, i.e. at a fixed pump-probe frequency shift. Strain measurements were acquired along an optical fiber attached to the structure, at a maximum acquisition rate of 250 Hz, a spatial resolution of 30 cm and a sampling distance of 5 cm in both x- and y-directions. A sequence of dynamic tests, aimed to evaluate the resonant frequencies and strain modal shapes of the structure, were performed on the plate for various boundary conditions (plate clamped with four, three or two bolts). Comparison with finite element method (FEM) analysis and dynamic strain measurements with strain gauges shows that Brillouin based distributed sensors can be usefully employed to perform the modal analysis of a vibrating structure, even if the spatial resolution is comparable with the plate dimensions.

  15. Comparison of 3M Petrifilm Aerobic Count Plates to standard plating methodology for use with AOAC antimicrobial efficacy methods 955.14, 955.15, 964.02, and 966.04 as an alternative enumeration procedure: collaborative study.

    PubMed

    Nelson, Maria T; LaBudde, Robert A; Tomasino, Stephen F; Pines, Rebecca M

    2013-01-01

    A multilaboratory study was conducted to determine the equivalence of the 3M Petrifilm Aerobic Count Plate and standard plating methodology for measuring viable bacteria and spores recovered from hard-surface carriers (stainless steel and porcelain), also known as "control carrier counts," used in AOAC antimicrobial efficacy test methods. Six laboratories participated in the study in which carriers inoculated with Staphylococcus aureus, Pseudomonas aeruginosa, Salmonella enterica, and spores of Bacillus subtilis were evaluated using 3M Petrifilm Aerobic Count (AC) plates and standard plating side-by-side. The data were analyzed using a matched-pair t-test to determine the between-method effect with confidence intervals. For all test organisms pooled across all laboratories, the mean difference in log10 concentration between the standard plate count method and 3M Petrifilm AC Plates was -0.012, with a 95% confidence interval of (-0.090, +0.066), which was well within the -0.5, +0.5 interval established as the acceptance criterion. The between-carrier SD averaged 0.139; the between-replicate SD was 0.050. The carrier reproducibility, given that a single replicate per carrier is done, was estimated to be 0.148. Although differences were seen in the final concentrations of the test organisms among laboratories, there were no statistical differences between the enumeration methods. Based on the results from this study, 3M Petrifilm AC Plates are equivalent to standard plating methodology and can be used as an alternative procedure for the enumeration of test organisms used in AOAC Methods 955.14, 955.15, 964.02, and 966.04.

  16. A prediction method for separating and quantifying noise contributions from casings and other plate like components in complex machines

    NASA Astrophysics Data System (ADS)

    Nejade, A.

    2012-11-01

    In the context of noise source identification in machines, sound intensity, pressure or velocity distributions on a plane in space are commonly provided by intensity or holography maps. These maps, however, are not capable of separating the sources that are located on different planes, e.g. machines' radiating casings versus internal noise sources. The method discussed in this paper has been developed to analyze such situations. It consists of multiple partially coherent inputs-single output modeling to predict the radiations generated by machine casings or other plate like components. A parallel analysis with intensity will then enable to separate the casing or plate contribution from those of the internal sources. The application of this technique must, however, be accompanied by tools that allow to check its validity. Several of such tools are suggested. The method applications and validity checks have been discussed for a grinder wheel guard and a panel saw's blade casing.

  17. Evaluation of the antibacterial effects of vancomycin hydrochloride released from agar-gelatin-bioactive glass composites.

    PubMed

    Rivadeneira, Josefina; Di Virgilio, Ana Laura; Audisio, M Carina; Boccaccini, Aldo R; Gorustovich, Alejandro A

    2015-01-13

    The aim of this work was to evaluate the perfomance of agar-gelatin (AG) composites and AG-containing 45S5 bioactive glass (BG) microparticles (AGBG) in relation to their water uptake capacity, sustained release of a drug over time, and antibacterial effects. The composites were fabricated by the gel-casting method. To impart the local drug release capacity, vancomycin hydrochloride (VC) was loaded in the composites in concentrations of 0.5 and 1 mg ml(-1). VC release was assessed in distilled water at 37 °C up to 72 h and quantified spectrophotometrically. The antibacterial activity of composites was evaluated by the inhibition zone test and the plate count method. The experiments were performed in vitro up to 48 h on three staphylococcus strains: Staphylococcus aureus ATCC29213, S. aureus ATCC6538 and Staphylococcus epidermidis ATCC12228. The results showed that the addition of BG to AG composites did not affect the degree of water uptake. The release of VC was significantly affected by the presence of BG. VC release was higher from AGBGVC films than from AGVC ones over prolonged incubation times. Bacterial inhibition zones were found around the composites. The halos were larger when the cells were put in contact with AGVC composites than when they were put in contact with AGBGVC ones. Nevertheless, the viable count method demonstrated that the composites inhibited Staphylococcus cell growth with no statistical differences. In conclusion, the addition of BG did not reflect an improvement in the parameters studied. On the other hand, composites loaded with VC would have a role in prophylaxis against bacterial infection.

  18. Comparison of agar-based media for primary isolation of glycopeptide-resistant enterococci.

    PubMed

    Chadwick, P. R.; Brown, D. F. J.; Wilcox, M. H.; Collyns, T. A.; Walpole, E.; Dillon, J.; Smith, R.; Gopal Rao, G.; Oppenheim, B. A.

    1997-01-01

    OBJECTIVE: To compare four vancomycin-containing agar media for the isolation of glycopeptide-resistant enterococci (GRE) from clinical fecal specimens: kanamycin---aesculin---azide (KAA) agar; bile---aesculin---polymixin (BAP) agar; aztreonam---amphotericin blood (CBAA) agar; and neomycin blood (CBN) agar. METHODS: Fecal specimens from 125 patients were inoculated onto each medium. Media were examined for enterococci after incubation for up to 48 h. Enterococci were identified to species level, and glycopeptide phenotypes were determined by measuring minimum inhibitory concentrations of vancomycin and teicoplanin. RESULTS: GRE were isolated from 44/125 samples. Enterococcus faecalis and Enterococcus faecium isolates, expressing glycopeptide resistance of the VanA or VanB phenotypes, were recovered from 27/33 (82%) specimens on BAP medium, 26/33 (79%) on KAA medium, and 21/33 (64%) on CBN and CBAA media. Enterococcus gallinarum and Enterococcus casseliflavus isolates expressing low-level glycopeptide resistance (VanC phenotype) were recovered from 14/15 (93%) specimens on CBAA medium, 7/15 (47%) on KAA and CBN media, and 6/15 (40%) on BAP medium. CONCLUSIONS: The media tested in this study, with the exception of CBN medium, detected at least 75% of patients colonized by GRE. Further development of BAP, CBAA and KAA media is warranted to improve growth and selectivity.

  19. Antimicrobial and physical-mechanical properties of agar-based films incorporated with grapefruit seed extract.

    PubMed

    Kanmani, Paulraj; Rhim, Jong-Whan

    2014-02-15

    The use of synthetic petroleum based packaging films caused serious environmental problems due to their difficulty in recycling and poor biodegradability. Therefore, present study was aimed to develop natural biopolymer-based antimicrobial packaging films as an alternative for the synthetic packaging films. As a natural antimicrobial agent, grapefruit seed extract (GSE) has been incorporated into agar to prepare antimicrobial packaging film. The films with different concentrations of GSE were prepared by a solvent casting method and the resulting composite films were examined physically and mechanically. In addition, the films were characterized by FE-SEM, XRD, FT-IR and TGA. The incorporation of GSE caused increase in color, UV barrier, moisture content, water solubility and water vapor permeability, while decrease in surface hydrophobicity, tensile strength and elastic modulus of the films. As the concentration of GSE increased from 0.6 to 13.3 μg/mL, the physical and mechanical properties of the films were affected significantly. The addition of GSE changed film microstructure of the film, but did not influence the crystallinity of agar and thermal stability of the agar-based films. The agar/GSE films exhibited distinctive antimicrobial activity against three test food pathogens, such as Listeria monocytogenes, Bacillus cereus and Escherichia coli. These results suggest that agar/GSE films have potential to be used in an active food packaging systems for maintaining food safety and extending the shelf-life of the packaged food.

  20. An equilibrium method for prediction of transverse shear stresses in a thick laminated plate

    NASA Technical Reports Server (NTRS)

    Chaudhuri, R. Z.

    1986-01-01

    First two equations of equilibrium are utilized to compute the transverse shear stress variation through thickness of a thick laminated plate after in-plane stresses have been computed using an assumed quadratic displacement triangular element based on transverse inextensibility and layerwise constant shear angle theory (LCST). Centroid of the triangle is the point of exceptional accuracy for transverse shear stresses. Numerical results indicate close agreement with elasticity theory. An interesting comparison between the present theory and that based on assumed stress hybrid finite element approach suggests that the latter does not satisfy the condition of free normal traction at the edge. Comparison with numerical results obtained by using constant shear angle theory suggests that LCST is close to the elasticity solution while the CST is closer to classical (CLT) solution. It is also demonstrated that the reduced integration gives faster convergence when the present theory is applied to a thin plate.

  1. Static analysis of the hull plate using the finite element method

    NASA Astrophysics Data System (ADS)

    Ion, A.

    2015-11-01

    This paper aims at presenting the static analysis for two levels of a container ship's construction as follows: the first level is at the girder / hull plate and the second level is conducted at the entire strength hull of the vessel. This article will describe the work for the static analysis of a hull plate. We shall use the software package ANSYS Mechanical 14.5. The program is run on a computer with four Intel Xeon X5260 CPU processors at 3.33 GHz, 32 GB memory installed. In terms of software, the shared memory parallel version of ANSYS refers to running ANSYS across multiple cores on a SMP system. The distributed memory parallel version of ANSYS (Distributed ANSYS) refers to running ANSYS across multiple processors on SMP systems or DMP systems.

  2. Gel microbead cultivation with a subenrichment procedure can yield better bacterial cultivability from a seawater sample than standard plating method

    NASA Astrophysics Data System (ADS)

    Ji, Shiqi; Zhao, Rui; Yin, Qi; Zhao, Yuan; Liu, Chenguang; Xiao, Tian; Zhang, Xiaohua

    2012-03-01

    A gel microbead (GMD) cultivation method was employed to cultivate microorganisms from an amphioxus breeding zone in Qingdao, P. R. China. The culture results were compared with those by standard plating method. In the GMD-based method, the microcolony-forming GMDs were sorted by fluorescence-activated cell sorting (FACS). To further get pure cultures, a subsequent enrichment culture and a streaking purification procedure were conducted on marine R2A medium. Eighty bacterial strains isolated by the GMD-based method were randomly selected for sequencing. These isolates belonged to Alphaproteobacteria (33%), Gammaproteobacteria (44%), Bacteroidetes (11%), Actinobacteria (5%), Firmicutes (5%), Epsilonproteobacteria (1%), and Verrucomicrobia (1%), the last two groups being usually difficult to culture. The 16S rRNA gene sequences revealed a diverse community with 91.1%-100% of the bacterial rRNAs similarities. Thirteen strains were sharing 16S rRNA gene sequence which was less than 97% similar to any other rRNA genes currently deposited in TYP16S database. Seventy isolates derived from the standard plating method fell into 4 different taxonomic groups: Alphaproteobacteria (9%), Gammaproteobacteria (81%), Bacteroidetes (7%) and Firmicutes (3%) with a 16S rRNA gene sequence similarities between 95.8%-100%, in which only 3 strains were sharing 16S rRNA gene sequence of less than 97%. The results indicated that the GMD-based method with subenrichment culture yielded more taxonomic groups and more novel microbial strains, including members of previously rarely cultured groups, when compared with the standard plating method, and that this method markedly improved the bacterial cultivability.

  3. Single vs. double layer suturing method repair of the urethral plate in the rabbit model of hypospadias

    PubMed Central

    Shirazi, Mehdi; Rahimi, Mohammad

    2016-01-01

    Introduction There are different methods of urethroplasty in hypospadias. The present study aimed to compare the repair of the urethral plate by single vs. double layer suturing. Material and methods Fifteen male rabbits were assigned to the control, single layer, and double layer urethral plate suturing groups (n = 5). Experimental hypospadias was induced in the second and third groups and the urethral plates were sutured. After two weeks, the penis was dissected out and underwent histopathological processing. Stereological studies were applied to obtain quantitative histological data regarding the structure of the urethra and the related part of the corpus spongiosum. Results Volume density of the urethral epithelium (the fraction of unit volume of the urethra occupied by its epithelium) was higher in the single layer suturing group when compared to the double layer or control groups (p <0.01). Additionally, the volume density of the urethral lumen (the fraction of the corpus spongiosum that is occupied by the urethral lumen) in the single versus the double layer suturing groups was respectively 2.4 and 2 folds higher than that in the control group (p <0.01). Besides, the volume density of the lumen was significantly higher in the single layer suturing when compared to the double layer suturing group (p <0.01). However, no significant difference was observed among the study groups regarding the volume density of the collagen and vessels in the incised site of the penis which implied that the fraction of the urethra and surrounding corpus spongiosum was occupied by collagen and vessels. Conclusions Urethral plate repair by the single layer suturing method could be accompanied by higher epithelialization and wider lumen in the rabbit model of hypospadias. PMID:28127462

  4. A method for measuring skin friction drag on a flat plate in contaminated gas flows

    NASA Technical Reports Server (NTRS)

    Oetting, R. B.; Patterson, G. K.

    1984-01-01

    A technique for measuring friction drag in turbulent gas and gas/particle flows over flat plates is presented, and preliminary results are reported. A 0.25-in.-thick 72 x 6-in. Al plate is suspended by six horizontal support air bearings and four vertical alignment air bearings between fixed dummy plates and leading-edge and trailing-edge fairings in the 32-in.-high 48-in.-wide 11-ft-long test section of a closed-circuit atmospheric wind tunnel operating at 50-150 ft/sec. Particles of Fe and Al oxides of diameter 20-150 microns and density up to 0.3 lb particles per lb air are injected via a 6 x 0.167-in. nozzle; turbulence is induced by a roughened section of the leading-edge fairing; and friction drag is measured using a load-cell pressure transducer. Sample results are shown in a graph, demonstrating good agreement with theoretical drag calculations.

  5. Selected elements in fly agaric Amanita muscaria.

    PubMed

    Falandysz, J; Kunito, T; Kubota, R; Lipka, K; Mazur, A; Falandysz, Justyna J; Tanabe, S

    2007-09-01

    Concentrations of Ag, Al, Ba, Ca, Cd, Co, Cu, Cr, Cs, Fe, Ga, Hg, K, Mg, Mn, Mo, Na, Pb, Rb, Se, Sb, Sr, V, Tl and Zn have been determined in the whole fruiting bodies, as well as separately in caps and stalks, of fly agaric collected from three geographically distant sites in northern part of Poland. The elements were determined using ICP-MS, ICP-OES, HG-AAS and CV-AAS, respectively. For elements such as Al, Ba, Cr, Fe, Ga, Mo, Mn, Pb, Sb, Sr, Tl, and V concentrations were similar in the caps and stalks, respectively, and for K, Zn, Ag, Ca, Cd, Cu, Hg, Mg, Rb and Se were greater in the caps, while for Co, Cs and Na in the stalks. For Ag, Al, Ba, Ca, Cd, Co, Cr, Cs, Fe, Ga, Hg, Mn, Mo, Pb, Rb, Sb, Sr, Tl and V concentration in the caps showed spatial variations (P<0.05), while for Cu, K, Mg, Na, Se and Zn was independent of the site. The elements such as K with median or mean in the caps between 37,000 and 43,000 microg/g.dm and Mg with 920 and 1,100 microg/g dm were most abundant. Next, within median values range from approximately 100 to 500 microg/g dm were such as Ca, Fe and Al, and in descending order they followed by Rb (100-400 microg/g dm); V, Na, Zn (50-200 microg/g dm); Cu, Mn (10-50 microg/g dm); Cd (10-20 microg/g dm); Se (5 microg/g dm); Ba (<1-3); Cr, Ag, Pb, Sr (<1-2 microg/g dm); Cs, Co, Hg (<1-1 microg/g dm); Ga (<0.5), Sb, Mo and Tl (<0.1 microg/g dm).

  6. A correlation method to predict the surface pressure distribution on an infinite plate from which a jet is issuing. [effects of a lifting jet

    NASA Technical Reports Server (NTRS)

    Perkins, S. C., Jr.; Menhall, M. R.

    1978-01-01

    A correlation method to predict pressures induced on an infinite plate by a jet issuing from the plate into a subsonic free stream was developed. The complete method consists of an analytical method which models the blockage and entrainment properties of the jet and a correlation which accounts for the effects of separation. The method was developed for jet velocity ratios up to ten and for radial distances up to five diameters from the jet. Correlation curves and data comparisons are presented for jets issuing normally from a flat plate with velocity ratios one to twelve. Also, a list of references which deal with jets in a crossflow is presented.

  7. Homogeneous Matrix Deposition on Dried Agar for MALDI Imaging Mass Spectrometry of Microbial Cultures

    NASA Astrophysics Data System (ADS)

    Hoffmann, Thomas; Dorrestein, Pieter C.

    2015-11-01

    Matrix deposition on agar-based microbial colonies for MALDI imaging mass spectrometry is often complicated by the complex media on which microbes are grown. This Application Note demonstrates how consecutive short spray pulses of a matrix solution can form an evenly closed matrix layer on dried agar. Compared with sieving dry matrix onto wet agar, this method supports analyte cocrystallization, which results in significantly more signals, higher signal-to-noise ratios, and improved ionization efficiency. The even matrix layer improves spot-to-spot precision of measured m/z values when using TOF mass spectrometers. With this technique, we established reproducible imaging mass spectrometry of myxobacterial cultures on nutrient-rich cultivation media, which was not possible with the sieving technique.

  8. [Presumptive identification of Candida spp. and other clinically important yeasts: usefulness of Brilliance Candida Agar].

    PubMed

    Alfonso, Claudia; López, Mónica; Arechavala, Alicia; Perrone, María Del Carmen; Guelfand, Liliana; Bianchi, Mario

    2010-06-30

    Fungal infections caused by yeasts have increased during the last decades and invasive forms represent a serious problem for human health. Candida albicans is the species most frequently isolated from clinical samples. However, other emerging yeast pathogens are increasingly responsible for mycotic infections, and some of them are resistant to some antifungal drugs. Consequently, it is necessary to have methods that can provide a rapid presumptive identification at species level. Numerous chromogenic agar media have been shown to be of value as diagnostic tools. We have compared a chromogenic medium, Brilliance Candida Agar, with CHROMagar Candida, the chromogenic medium most used in our country. A multicentre study was conducted in 16 Hospitals belonging to the Mycology Net of Buenos Aires City Government. A total of 240 yeast isolates were included in this research. The new chromogenic agar showed results very similar to those obtained with CHROMagar Candida.

  9. Agar blue localization of small pulmonary nodules and ground glass opacifications for thoracoscopic resection

    PubMed Central

    2016-01-01

    Background Screening for lung cancer using high resolution computed tomography (CT) has produced encouraging early results. Extremely small nodules and non-palpable areas of opacifications are able to be detected, but pose a challenge to the thoracic surgeon trying to resect these areas. Methods Forty five patients with ground glass opacifications (GGOs) or small pulmonary nodules underwent pre-operative CT-guided placement of methylene blue dyed agar and/or hook wire needle localization prior to thoracoscopic resection. Progel was applied to any intraoperative air leaks observed after successful resection. Results All lesions were successfully excised thoracoscopically. The blue agar aided in localization of these areas and did not affect the histological architecture during pathologic evaluation. Conclusions Careful pre-operative evaluation and planning, including use of selective CT-guided blue agar localization and hook wire placement, may greatly assist in thoracoscopically locating and resecting these often difficult-to-visualize lesions. PMID:28066669

  10. Comparison of direct and enrichment methods for the selective isolation of vancomycin-resistant enterococci from feces of pigs and poultry.

    PubMed

    Butaye, P; Devriese, L A; Haesebrouck, F

    1999-01-01

    Isolation results of vancomycin-resistant enterococci (VRE) of fecal samples from pigs and broiler and layer chickens obtained with two vancomycin-supplemented enrichment media, kanamycin aesculin azide (KAA) broth and Enterococcosel (ECC) broth, and three isolation media, KAA agar, ECC agar, and Slanetz and Bartley (SL) agar, were compared. Direct isolation on vancomycin-containing agar plates was not efficient in swine and layer chickens, which had only low numbers of VRE. In broilers chickens, the VRE content of the samples was high, and SL as well as ECC were found to perform better than KAA agar. The same three agar media were used as selective plating media after 1 and 2 days incubation of the samples in KAA and ECC enrichment broths. Sensitivities of the 12 different enrichment-plate combinations tested ranged from 0 to 81% in layer chickens and from 5 to 44% in samples from pigs. In the high prevalence type of samples from broilers, sensitivities still varied substantially from 52 to 78%. Incubating vancomycin-containing enrichment broths for 2 days compared with 1 day was favorable for the isolation of vancomycin-resistant Enterococcus faecalis, E. gallinarum, and E. casseliflavus but not for E. faecium and E. hirae/E. durans. ECC broth and ECC plates yielded the highest number of E. gallinarum and E. casseliflavus. In layer as well as in broiler chickens, ECC broth incubated for 2 days and plated on ECC agar was the most sensitive method. In pigs, however, KAA broth incubated for 2 days and plated on ECC medium yielded the highest number of VRE.

  11. Isolation and characterization of agar-digesting Vibrio species from the rotten thallus of Gracilariopsis heteroclada Zhang et Xia.

    PubMed

    Martinez, Joval N; Padilla, Philip Ian P

    2016-08-01

    Gracilariopsis heteroclada Zhang et Xia (Gracilariaceae, Rhodophyta) is one of the most studied marine seaweeds due to its economic importance. This has been cultivated extensively on commercial scale in the Philippines and other Asian countries. However, sustainable production of G. heteroclada in the Philippines could not be maximized due to the occurrence of rotten thallus disease. Thus, isolation and characterization of agar-digesting bacteria from the rotten thalli of G. heteroclada was conducted. A total of seven representative bacterial isolates were randomly selected based on their ability to digest agar as evidenced by the formation of depressions around the bacterial colonies on nutrient agar plates supplemented with 1.5% NaCl and liquefaction of agar. Gram-staining and biochemical characterization revealed that isolates tested were gram-negative rods and taxonomically identified as Vibrio parahaemolyticus (86-99.5%) and Vibrio alginolyticus (94.2-97.7%), respectively. It is yet to be confirmed whether these agar-digesting vibrios are involved in the induction and development of rotten thallus disease in G. heteroclada in concomitance with other opportunistic bacterial pathogens coupled with adverse environmental conditions.

  12. Comparison of inhibitory mold agar to Sabouraud dextrose agar as a primary medium for isolation of fungi.

    PubMed

    Scognamiglio, Theresa; Zinchuk, Riva; Gumpeni, Pramod; Larone, Davise H

    2010-05-01

    Clinical specimens cultured on two selective fungal media, inhibitory mold agar (IMA) and Sabouraud dextrose agar (SDA), were compared with respect to recovery of fungi. Of the 840 fungal isolates recovered, 69.3% grew on both IMA and SDA; 24.9% grew only on IMA; and 5.8% grew only on SDA, showing that IMA is superior (P=0.003).

  13. Selection of brain metastasis-initiating breast cancer cells determined by growth on hard agar.

    PubMed

    Guo, Lixia; Fan, Dominic; Zhang, Fahao; Price, Janet E; Lee, Ju-Seog; Marchetti, Dario; Fidler, Isaiah J; Langley, Robert R

    2011-05-01

    An approach that facilitates rapid isolation and characterization of tumor cells with enhanced metastatic potential is highly desirable. Here, we demonstrate that plating GI-101A human breast cancer cells on hard (0.9%) agar selects for the subpopulation of metastasis-initiating cells. The agar-selected cells, designated GI-AGR, were homogeneous for CD44(+) and CD133(+) and five times more invasive than the parental GI-101A cells. Moreover, mice injected with GI-AGR cells had significantly more experimental brain metastases and shorter overall survival than did mice injected with GI-101A cells. Comparative gene expression analysis revealed that GI-AGR cells were markedly distinct from the parental cells but shared an overlapping pattern of gene expression with the GI-101A subline GI-BRN, which was generated by repeated in vivo recycling of GI-101A cells in an experimental brain metastasis model. Data mining on 216 genes shared between GI-AGR and GI-BRN breast cancer cells suggested that the molecular phenotype of these cells is consistent with that of cancer stem cells and the aggressive basal subtype of breast cancer. Collectively, these results demonstrate that analysis of cell growth in a hard agar assay is a powerful tool for selecting metastasis-initiating cells in a heterogeneous population of breast cancer cells, and that such selected cells have properties similar to those of tumor cells that are selected based on their potential to form metastases in mice.

  14. The use of agar as a novel filler for monolithic matrices produced using hot melt extrusion.

    PubMed

    Lyons, John G; Devine, Declan M; Kennedy, James E; Geever, Luke M; O'Sullivan, Patrick; Higginbotham, Clement L

    2006-08-01

    The use of filler materials in an extended release monolithic polymer matrix can lead to a vastly altered release profile for the active pharmaceutical ingredient. A range of excipients for use in monolithic matrices have been discussed in the literature. The body of work described in this research paper outlines the use of agar as a novel filler material in a hot melt extruded polymer matrix. Several batches of matrix material were prepared with Diclofenac sodium used as the active pharmaceutical ingredient (API). Agar and microcrystalline cellulose were used as the filler materials in varying ratios, to examine the effect of % filler content as well as filler type on the properties of the hot melt extruded matrix. The resultant extrudates were characterised using steady state parallel plate rheometry, differential scanning calorimetry (DSC) and dissolution testing. The rheometry analysis concluded that the fillers used resulted in an increase in the matrix viscosity. The DSC scans obtained showed negligible effects on the melting behavior of the matrix as a result of the filler inclusion. Dissolution analysis showed that the presence of the fillers resulted in a slower release rate of API than for the matrix alone. The results detailed within this paper indicate that agar is a viable filler for extended release hot melt produced dosage forms.

  15. Confocal-based method for quantification of diffusion kinetics in microwell plates and its application for identifying a rapid mixing method for high-content/throughput screening.

    PubMed

    Song, Ok Ryul; Kim, Tae-Hee; Perrodon, Xavier; Lee, Changbok; Jeon, Hee Kyoung; Seghiri, Zahir; Kwon, Ho Jeong; Cechetto, Jonathan; Christophe, Thierry

    2010-02-01

    Rapid mixing in microplates is still an underappreciated challenge in screening assay development, particularly with the use of noncontact nanoliter liquid handlers. In high-content/throughput screening (HC/TS), fast and efficient mixing between compounds and cell culture medium is even more critical as biological kinetics dictates speed of mixing, usually within a few minutes. Moreover, mixing in HC/TS should be gentle enough to avoid any negative disruption in cell layer. Here the authors introduce a method to accurately quantify drop diffusion into a microplate well, independently of buffer, liquid handler, or dispensing protocol. This method was used to determine the effect of various mixing methods on the diffusion of a nanoliter drop of pure DMSO in aqueous buffer in 384-well plates. Rapid plate shaking and additional buffer addition were shown to be the most efficient and effective mixing methods for HC/TS. However, efficient mixing by plate shaking is limited by assay volume. Bulk addition shows fast and efficient mixing, without negative effects on cells. Moreover, this simple, fast, and inexpensive method can be easily adapted on any platform.

  16. Calculation by iterative method of linear viscoelastic plate under biaxial tension

    NASA Astrophysics Data System (ADS)

    Svetashkov, A. A.; Miciński, J.; Manabaev, K. K.; Vakurov, A. A.

    2017-02-01

    In this paper, we used the iterative solution algorithm, proposed in the work of Pavlov and Svetashkova. This algorithm results in a complete separation of spatial and temporal variables, if we set up the boundary loads and (or) volumetric forces in the same kind. In this paper, we have examined the stress-strain state of a viscoelastic plate, and the results of the calculation displacements, stresses are given. In addition, we made a comparison of the calculation indices rate of convergence for the iterative process with their theoretical values.

  17. Measuring the Average Thickness of a Plate Using a Bayesian Method and Free Vibration Data

    DTIC Science & Technology

    2011-09-01

    form, the model is constructed with the implicit assumption that the corrosion is uniform. A more detailed model that included details of the pitting ...PROCEDURE The test specimen was a 0.76m by 0.60m (30” by 24”, 5:4 aspect ratio), 1.55mm (1/16”) thick 6061 -T6 aluminum plate. The density was...considering corrosion effect.” Marine Struc- tures, 21(4):402 – 419. [3] T. Nakai, H. Matsushita, N. Yamamoto, and H. Arai, 2004. “Effect of pitting

  18. Enumeration of fungi in fruits by the most probable number method.

    PubMed

    Watanabe, Maiko; Tsutsumi, Fumiyuki; Lee, Ken-ichi; Sugita-Konishi, Yoshiko; Kumagai, Susumu; Takatori, Kosuke; Hara-Kudo, Yukiko; Konuma, Hirotaka

    2010-01-01

    In this study, enumeration methods for fungi in foods were evaluated using fruits that are often contaminated by fungi in the field and rot because of fungal contaminants. As the test methods, we used the standard most probable number (MPN) method with liquid medium in test tubes, which is traditionally used as the enumeration method for bacteria, and the plate-MPN method with agar plate media, in addition to the surface plating method as the traditional enumeration method for fungi. We tested 27 samples of 9 commercial domestic fruits using their surface skin. The results indicated that the standard MPN method showed slow recovery of fungi in test tubes and lower counts than the surface plating method and the plate-MPN method in almost all samples. The fungal count on the 4th d of incubation was approximately the same as on the 10th d by the surface plating method or the plate-MPN method, indicating no significant differences between the fungal counts by these 2 methods. This result indicated that the plate-MPN method had a number agreement with the traditional enumeration method. Moreover, the plate-MPN method has a little laborious without counting colonies, because fungal counts are estimated based on the number of plates with growing colonies. These advantages demonstrated that the plate-MPN method is a comparatively superior and rapid method for enumeration of fungi.

  19. Analytical-variational method of analysis about a finite plate with a cracked hole stiffened by a ring with rivet joints

    NASA Astrophysics Data System (ADS)

    Fu, Dong-Shan; Zhang, Xing

    1995-02-01

    -An analytical-variational method is presented for the solution of a finite plate with both an unloaded cracked large hole and loaded uncracked small holes. This method is also used to solve a problem of a ring with loaded uncracked small holes only. On the foundation of the above analysis, a classical force method is used to solve a problem of a finite plate with a cracked hole stiffened by a ring with rivet joints for determination of rivet forces, stress intensity factor in the stiffened finite plate with a cracked hole and the stress concentration factor in the stiffening ring.

  20. Stabilized copper plating method by programmed electroplated current: Accumulation of densely packed copper grains in the interconnect

    NASA Astrophysics Data System (ADS)

    Kao, Li-Chi; Hsu, Li-Hsuan; Brahma, Sanjaya; Huang, Bo-Chia; Liu, Chun-Chu; Lo, Kuang-Yao

    2016-12-01

    In this work, we programmed the plating current to stack the different size of copper (Cu) grain and analyzed the relation between the sequence of different Cu grain size and the stability of the residual stress. The residual stress was measured with varying times of annealing process in order to reach the purpose of simulating the actual Cu interconnect process. We found that varied plating strategy will make different stabilization condition of residual stress through the proof of X-ray diffraction (XRD) and optical parallel beams reflection (PBR) method. The accumulation of Cu grains, formed by Cu grain with successive variation in grain size, would enhance the packing density better than only single grain size in the finite space. The high density of the grain boundary in the electroplated Cu film will be eliminated through annealing process and it will help to suppress the void formation in further interconnect process. The electroplated Cu film with the plating current of saw tooth wave can soon reach a stable tensile stress through annealing since the Cu grains with high packing density will be quickly eliminated to approach the minimum of the strain energy which reflects to variation in the texture of Cu (2 0 0). The result of this work illustrates the importance of how to stack different size of Cu grain, for achieving a densely packed Cu film which close to the Cu bulk.

  1. Comparison of methods for the detection of biofilm formation by Staphylococcus aureus isolated from bovine subclinical mastitis

    PubMed Central

    de Castro Melo, Poliana; Ferreira, Luciano Menezes; Filho, Antônio Nader; Zafalon, Luiz Francisco; Vicente, Hinig Isa Godoy; de Souza, Viviane

    2013-01-01

    Biofilm formation is considered to be a selective advantage for Staphylococcus aureus mastitis isolates by facilitating bacterial persistence in the udder. It requires attachment to mammary epithelium, proliferation and accumulation of cells in multilayers. The objective of this study was to determine the sensitivity and specificity of three techniques for the detection of S. aureus biofilm-positive strains. Two phenotypic tests, including growth on microtitre plates and Congo red agar, were compared with a PCR technique using 94 S. aureus strains obtained from cows with subclinical mastitis from two farms in the state of São Paulo. These strains were characterised by in vitro slime production on Congo red agar, biofilm formation on microtitre plates and the presence of the icaA and icaD genes. The results revealed that 85% of the isolates tested produced slime on the Congo red agar, 98.9% of the isolates produced biofilms in vitro by adhering to sterile 96-well “U” bottom polystyrene tissue culture plates, and 95.7% of the isolates carried the icaA and icaD genes. The results of the phenotypic tests for biofilm formation were compared with those of the molecular analysis, and the sensitivity and specificity of the Congo red agar test were 88.9% and 100%, respectively, while those of the microtitre plate test were 100% and 25%, respectively. When the phenotypic methods for the detection of biofilm producers, namely growth on microtitre plates and Congo red agar, were compared, the sensitivity and specificity were 86% and 100%, respectively. Therefore, growth on Congo red agar and the microtitre plate test are methods that could be used to determine whether an isolate has the potential for biofilm production. PMID:24159293

  2. A Simplified Culture Method for Specific Diagnosis of Cerebrospinal Meningitis.

    DTIC Science & Technology

    efficient than chocolate agar and blood agar plates when tested in parallel on 460 cerebrospinal fluid specimens. The culture bottles are inexpensive, portable, and durable making them highly suited to studies in the field. (Author)

  3. Equivalency testing of TTC Tergitol 7 agar (ISO 9308-1:2000) with five culture media for the detection of E. coli in water samples in Greece.

    PubMed

    Mavridou, A; Smeti, E; Mandilara, G; Mandilara, G; Boufa, P; Vagiona-Arvanitidou, M; Vantarakis, A; Vassilandonopoulou, G; Pappa, O; Roussia, V; Tzouanopoulos, A; Livadara, M; Aisopou, I; Maraka, V; Nikolaou, E; Mandilara, G

    2010-01-01

    In this study ten laboratories in Greece compared the performance of reference method TTC Tergitol 7 Agar (with the additional test of beta-glucuronidase production) with five alternative methods, to detect E. coli in water, in line with European Water Directive recommendations. The samples were prepared by spiking drinking water with sewage effluent following a standard protocol. Chlorinated and non-chlorinated samples were used. The statistical analysis was based on the mean relative difference of confirmed counts and was performed in line with ISO 17994. The results showed that in total, three of the alternative methods (Chromocult Coliform agar, Membrane Lauryl Sulfate agar and Trypton Bilex-glucuronidase medium) were not different from TTC Tergitol 7 agar (TTC Tergitol 7 agar vs Chromocult Coliform agar, 294 samples, mean RD% 5.55; vs MLSA, 302 samples, mean RD% 1; vs TBX, 297 samples, mean RD% -2.78). The other two alternative methods (Membrane Faecal coliform medium and Colilert 18/ Quantitray) gave significantly higher counts than TTC Tergitol 7 agar (TTC Tergitol 7 agar vs MFc, 303 samples, mean RD% 8.81; vs Colilert-18/Quantitray, 76 samples, mean RD% 18.91). In other words, the alternative methods generated performance that was as reliable as, or even better than, the reference method. This study will help laboratories in Greece overcome culture and counting problems deriving from the EU reference method for E. coli counts in water samples.

  4. Acanthamoeba can be differentiated by the polymerase chain reaction and simple plating assays.

    PubMed

    Khan, N A; Jarroll, E L; Paget, T A

    2001-09-01

    Acanthamoeba are opportunistic pathogens with invasive and noninvasive species. For clinical purposes it is important to differentiate potentially pathogenic from nonpathogenic isolates. For the rapid and sensitive identification of Acanthamoeba at the genus level, we used a polymerase chain reaction (PCR)-based method which detected as few as five cells. Further, we tested nine isolates of Acanthamoeba for their ability to produce cytopathic effects (CPE) on corneal epithelial cells. On the basis of the results, Acanthamoeba were divided into pathogenic or nonpathogenic groups. However, because CPE assays are not available to every diagnostic laboratory, we developed a simple plating assay based on osmotolerance which correlated well with the CPE assays. Pathogenic Acanthamoeba showed growth on higher osmolarity (agar plates containing one molar mannitol), while growth of nonpathogens was inhibited on these plates. In conclusion, we have developed methods for the rapid identification and differentiation of Acanthamoeba.

  5. Fracture Toughness of Thin Plates by the Double-Torsion Test Method

    NASA Technical Reports Server (NTRS)

    Salem, Jonathan A.; Radovic, Miladin; Lara-Curzio, Edgar; Nelson, George

    2006-01-01

    Double torsion testing can produce fracture toughness values without crack length measurement that are comparable to those measured via standardized techniques such as the chevron-notch, surface-crack-in-flexure and precracked beam if the appropriate geometry is employed, and the material does not exhibit increasing crack growth resistance. Results to date indicate that 8 < W/d < 80 and L/W > 2 are required if crack length is not considered in stress intensity calculations. At L/W = 2, the normalized crack length should be 0.35 < a/L < 0.65; whereas for L/W = 3, 0.2 < a/L < 0.75 is acceptable. In addition, the load-points need to roll to reduce friction. For an alumina exhibiting increasing crack growth resistance, values corresponding to the plateau of the R-curve were measured. For very thin plates (W/d > 80) nonlinear effects were encountered.

  6. Effect of water structure on gelation of agar in glycerol solutions and phase diagram of agar organogels.

    PubMed

    Boral, Shilpi; Bohidar, H B

    2012-06-21

    A comprehensive study of hydration of polyanionic agar molecules in its solution and gel phase in glycerol-water binary solvent is reported. Raman spectroscopy results predict differential water structure arrangement for glycerol-water binary solvent, 0.02% (w/v) agar in glycerol solution and 0.3% (w/v) agar organogel. The 3200 cm(-1) Raman band pertaining to ice-like structure of water was found to increase in gel phase alike in glycerol-water solvent while it decreased in agar solutions with increase in glycerol concentration. In contrast, the partially structured water corresponding to the component 3310 cm(-1) of Raman spectra increased in agar solution, and decreased in gel phase similar to glycerol-water solvent case. We have explained these observations based on a simple model where the available oxygen to hydrogen atom ratio in a given solvent-polymer system uniquely defines hydration in solution and gel phases. The gelation concentration was found to increase from 0.18 (for water) to 0.22% (w/v) (50% v/v glycerol solution) as the glycerol concentration was raised. Correspondingly, the gelation temperature, T(g), showed a decline from 40 to 20 °C, and the gel melting temperature, T(m), revealed a reduction from 81 to 65 °C in the same glycerol concentration regime. Two distinctive features are evident here: (i) presence of glycerol as a cosolvent does not favor the gelation of agar as compared to water and (ii) agar organogels are softer than their hydrogels. A unique 3D phase diagram for the agar organogel is proposed. Circular dichroism data confirmed that the agar molecules retained their biological activity in these solvents. Thus, it is shown that thermo-mechanical properties of these organogels could be systematically tuned and adapted as per application requirement.

  7. Alternative method for measuring effective focal length of lenses using the front and back surface reflections from a reference plate.

    PubMed

    Kim, Do-Hyun; Shi, Dexiu; Ilev, Ilko K

    2011-09-10

    We present a simple method for measuring the effective focal length without determining the location of principle plane of the lens. The method is based on the measurement of confocal backreflection axial responses from the front and back surfaces of a reference plate with known refractive index and thickness. We proved the concept by measuring the effective focal lengths of thin singlet lenses and complex microscope objectives. The theoretical limit of measurement precision varies depending on the numerical aperture of the lens. This method can provide an alternative focal length measurement method for complex lenses or lenses that are permanently attached to other structures. Measurement errors were analyzed theoretically and improvements in measurement accuracy were discussed.

  8. Comparison of dry medium culture plates for mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet products.

    PubMed

    Park, Junghyun; Kim, Myunghee

    2013-12-01

    This study was performed to compare the performance of Sanita-Kun dry medium culture plate with those of traditional culture medium and Petrifilm dry medium culture plate for the enumeration of the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet. Mesophilic aerobic bacteria were comparatively evaluated in milk, ice cream, ham, and codfish fillet using Sanita-Kun aerobic count (SAC), Petrifilm aerobic count (PAC), and traditional plate count agar (PCA) media. According to the results, all methods showed high correlations of 0.989~1.000 and no significant differences were observed for enumerating the mesophilic aerobic bacteria in the tested food products. SAC method was easier to perform and count colonies efficiently as compared to the PCA and PAC methods. Therefore, we concluded that the SAC method offers an acceptable alternative to the PCA and PAC methods for counting the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet products.

  9. Plate motion

    SciTech Connect

    Gordon, R.G. )

    1991-01-01

    The motion of tectonic plates on the earth is characterized in a critical review of U.S. research from the period 1987-1990. Topics addressed include the NUVEL-1 global model of current plate motions, diffuse plate boundaries and the oceanic lithosphere, the relation between plate motions and distributed deformations, accelerations and the steadiness of plate motions, the distribution of current Pacific-North America motion across western North America and its margin, plate reconstructions and their uncertainties, hotspots, and plate dynamics. A comprehensive bibliography is provided. 126 refs.

  10. Evaluation of optical parameters of quasi-parallel plates with single-frame interferogram analysis methods and eliminating the influence of camera parasitic fringes

    NASA Astrophysics Data System (ADS)

    Sunderland, Zofia; Patorski, Krzysztof; Wielgus, Maciek; Pokorski, Krzysztof

    2014-12-01

    The surface flatness of transparent plates is frequently tested in Fizeau and Twyman-Green interferometers. In case of quasi-parallel plates, however, a common problem is the additional reflection from the plate rear surface and the occurence of three-beam interference. Conventional methods of interferogram analysis such as temporal phase shifting or Fourier transform fail when the three overlapping fringe sets are present in the image. Our method of deriving optical parameters of the plate requires recording two interferograms: a two-beam interferogram without a reference beam and the three-beam interference one. The images are processed using single-frame techniques only and information about shape of both surfaces and optical thickness variations of the plate is retrieved. Unwanted parasitic fringes introduced by the glass plate protecting the CCD matrix in the camera are also handled using recently developed special smoothing technique. The proposed method is based on algorithmic solution and does not require modification of a sample or the optical setup. The measurement procedure and the detailed image processing path will be presented on the example of quasi-parallel plate interferograms recorded in the Twyman-Green setup.

  11. Multipotent Mesenchymal Stromal Stem Cell Expansion by Plating Whole Bone Marrow at a Low Cellular Density: A More Advantageous Method for Clinical Use

    PubMed Central

    Mareschi, Katia; Rustichelli, Deborah; Calabrese, Roberto; Gunetti, Monica; Sanavio, Fiorella; Castiglia, Sara; Risso, Alessandra; Ferrero, Ivana; Tarella, Corrado; Fagioli, Franca

    2012-01-01

    Mesenchymal stem cells (MSCs) are a promising source for cell therapy due to their pluripotency and immunomodulant proprieties. As the identification of “optimal” conditions is important to identify a standard procedure for clinical use. Percoll, Ficoll and whole bone marrow directly plated were tested from the same sample as separation methods. The cells were seeded at the following densities: 100 000, 10 000, 1000, 100, 10 cells/cm2. After reaching confluence, the cells were detached, pooled and re-plated at 1000, 500, 100, and 10 cells/cm2. Statistical analyses were performed. Cumulative Population Doublings (PD) did not show significant differences for the separation methods and seeding densities but only for the plating density. Some small quantity samples plated in T25 flasks at plating densities of 10 and 100 cells/cm2 did not produce any expansion. However, directly plated whole bone marrow resulted in a more advantageous method in terms of CFU-F number, cellular growth and minimal manipulation. No differences were observed in terms of gross morphology, differentiation potential or immunophenotype. These data suggest that plating whole bone marrow at a low cellular density may represent a good procedure for MSC expansion for clinical use. PMID:23715383

  12. Evaluation of potassium-clavulanate-supplemented modified charcoal-cefoperazone-deoxycholate agar for enumeration of Campylobacter in chicken carcass rinse.

    PubMed

    Chon, Jung-Whan; Kim, Hong-Seok; Kim, Hyunsook; Oh, Deog-Hwan; Seo, Kun-Ho

    2014-05-01

    Potassium-clavulanate-supplemented modified charcoal-cefoperazone-deoxycholate agar (C-mCCDA) that was described in our previous study was compared with original mCCDA for the enumeration of Campylobacter in pure culture and chicken carcass rinse. The quantitative detection of viable Campylobacter cells from a pure culture, plated on C-mCCDA, is statistically similar (P > 0.05) to mCCDA. In total, 120 chickens were rinsed using 400 mL buffered peptone water. The rinses were inoculated onto C-mCCDA and mCCDA followed by incubation at 42 °C for 48 h. There was no statistical difference between C-mCCDA (45 of 120 plates; mean count, 145.5 CFU/mL) and normal mCCDA (46 of 120 plates; mean count, 160.8 CFU/mL) in the isolation rate and recovery of Campylobacter (P > 0.05) from chicken carcass rinse. The Pearson correlation coefficient value for the number of Campylobacter cells recovered in the 2 media was 0.942. However, the selectivity was much better on C-mCCDA than on mCCDA plates (P < 0.05). Significantly fewer C-mCCDA plates (33 out of 120 plates; mean count, 1.9 CFU/mL) were contaminated with non-Campylobacter cells than the normal mCCDA plates (67 out of 120 plates; mean count, 27.1 CFU/mL). The C-mCCDA may provide improved results for enumeration of Campylobacter in chicken meat alternative to mCCDA with its increased selectivity the modified agar possess.

  13. Evaluation of the petrifilm aerobic count plate for enumeration of aerobic marine bacteria from seawater and Caulerpa lentillifera.

    PubMed

    Kudaka, Jun; Horii, Toru; Tamanaha, Koji; Itokazu, Kiyomasa; Nakamura, Masaji; Taira, Katsuya; Nidaira, Minoru; Okano, Sho; Kitahara, Akio

    2010-08-01

    The enumeration and evaluation of the activity of marine bacteria are important in the food industry. However, detection of marine bacteria in seawater or seafood has not been easy. The Petrifilm aerobic count plate (ACP) is a ready-to-use alternative to the traditional enumeration media used for bacteria associated with food. The purpose of this study was to evaluate the usefulness of a simple detection and enumeration method utilizing the Petrifilm ACP for enumeration of aerobic marine bacteria from seawater and an edible seaweed, Caulerpa lentillifera. The efficiency of enumeration of total aerobic marine bacteria on Petrifilm ACP was compared with that using the spread plate method on marine agar with 80 seawater and 64 C. lentillifera samples. With sterile seawater as the diluent, a close correlation was observed between the method utilizing Petrifilm ACP and that utilizing the conventional marine agar (r=0.98 for seawater and 0.91 for C. lentillifera). The Petrifilm ACP method was simpler and less time-consuming than the conventional method. These results indicate that Petrifilm ACP is a suitable alternative to conventional marine agar for enumeration of marine microorganisms in seawater and C. lentillifera samples.

  14. Simulative method for determining the optimal operating conditions for a cooling plate for lithium-ion battery cell modules

    NASA Astrophysics Data System (ADS)

    Smith, Joshua; Hinterberger, Michael; Hable, Peter; Koehler, Juergen

    2014-12-01

    Extended battery system lifetime and reduced costs are essential to the success of electric vehicles. An effective thermal management strategy is one method of enhancing system lifetime increasing vehicle range. Vehicle-typical space restrictions favor the minimization of battery thermal management system (BTMS) size and weight, making their production and subsequent vehicle integration extremely difficult and complex. Due to these space requirements, a cooling plate as part of a water-glycerol cooling circuit is commonly implemented. This paper presents a computational fluid dynamics (CFD) model and multi-objective analysis technique for determining the thermal effect of coolant flow rate and inlet temperature in a cooling plate-at a range of vehicle operating conditions-on a battery system, thereby providing a dynamic input for one-dimensional models. Traditionally, one-dimensional vehicular thermal management system models assume a static heat input from components such as a battery system: as a result, the components are designed for a set coolant input (flow rate and inlet temperature). Such a design method is insufficient for dynamic thermal management models and control strategies, thereby compromising system efficiency. The presented approach allows for optimal BMTS design and integration in the vehicular coolant circuit.

  15. Comparative evaluation of direct plating and most probable number for enumeration of low levels of Listeria monocytogenes in naturally contaminated ice cream products.

    PubMed

    Chen, Yi; Pouillot, Régis; S Burall, Laurel; Strain, Errol A; Van Doren, Jane M; De Jesus, Antonio J; Laasri, Anna; Wang, Hua; Ali, Laila; Tatavarthy, Aparna; Zhang, Guodong; Hu, Lijun; Day, James; Sheth, Ishani; Kang, Jihun; Sahu, Surasri; Srinivasan, Devayani; Brown, Eric W; Parish, Mickey; Zink, Donald L; Datta, Atin R; Hammack, Thomas S; Macarisin, Dumitru

    2017-01-16

    A precise and accurate method for enumeration of low level of Listeria monocytogenes in foods is critical to a variety of studies. In this study, paired comparison of most probable number (MPN) and direct plating enumeration of L. monocytogenes was conducted on a total of 1730 outbreak-associated ice cream samples that were naturally contaminated with low level of L. monocytogenes. MPN was performed on all 1730 samples. Direct plating was performed on all samples using the RAPID'L.mono (RLM) agar (1600 samples) and agar Listeria Ottaviani and Agosti (ALOA; 130 samples). Probabilistic analysis with Bayesian inference model was used to compare paired direct plating and MPN estimates of L. monocytogenes in ice cream samples because assumptions implicit in ordinary least squares (OLS) linear regression analyses were not met for such a comparison. The probabilistic analysis revealed good agreement between the MPN and direct plating estimates, and this agreement showed that the MPN schemes and direct plating schemes using ALOA or RLM evaluated in the present study were suitable for enumerating low levels of L. monocytogenes in these ice cream samples. The statistical analysis further revealed that OLS linear regression analyses of direct plating and MPN data did introduce bias that incorrectly characterized systematic differences between estimates from the two methods.

  16. Copper Plating Method on Flat Surface for High Frequency Signal Transfer

    NASA Astrophysics Data System (ADS)

    Hontake, Koichi; Wakizaka, Yasuhiro; Furuya, Akihiko; Uchida, Daisuke; Kuribayashi, Koichiro; Noda, Tomoko; Sugimura, Masahiko; Chikuma, Mitsuyasu; Toki, Sotaro; Sasaki, Jun; Hagiwara, Muneaki; Nakada, Akira; Kubota, Hiroshi

    2005-09-01

    A copper plating process for printed wiring boards operating in the GHz frequency range has been developed that improves the adhesion strength between the copper interconnects and the resin substrate by using an imidazole compound to form coordinate bonds. The coordinate bonds are prepared by impregnating the resin substrate with an aqueous solution of amino-group-containing imidazole (AI). The adhesion strength is measured by a tensile test with various concentrations of AI solution and different treatment times of impregnation. As a result, the highest adhesion strength of 4.2-5.1 N\\cdotcm-1 can be obtained on the entire surface of a 340× 340 mm2 substrate, where the flatness is down to 58.7 nm. This result is due to the optimization of the impregnating condition for AI and of the removal condition for weak boundary layers. The signal transmission characteristics of the interconnects on the substrates fabricated by this processes are compared with the conventional process by S21 parameter extraction in the GHz frequency range. The transmission characteristics of this process are markedly improved compared with those of conventional processes.

  17. Detection of Escherichia coli colonies on confluent plates of chromogenic media used in membrane filtration.

    PubMed

    Maheux, Andrée F; Dion-Dupont, Vanessa; Bisson, Marc-Antoine; Bouchard, Sébastien; Rodriguez, Manuel J

    2014-02-01

    MI agar (MI), Chromocult® Coliform agar ES (Chromocult), and DC with BCIG agar (DC) are chromogenic membrane filtration culture-based methods used to assess microbiological water quality. In this study, their ability to detect Escherichia coli colonies on confluent growth plates was determined by testing water samples containing increasing concentrations of a non-E. coli growing bacterium, Citrobacter youngae. Then, their ability to inhibit the growth of non-coliform bacteria was determined by simultaneously testing 603 well water samples. Results were compared with those obtained with mFC and Colilert® methods. Results showed that the E. coli count was difficult to determine on mFC, Chromocult and DC when non-E. coli colonies reached levels of 10(4)colony forming units (CFU)/100 mL. However, the E. coli count did not interfere with Colilert until non-E. coli colonies reached concentrations of 10(7)CFU/100 mL. No inhibition was observed with MI as E. coli colonies could be easily detected in the presence of at least 10(7)CFU/100 mL of C. youngae. Using well water samples, confluent growth plates were observed for 144, 177, and 185 of the 603 well water samples tested with the MI, Chromocult and DC methods, respectively. Among these confluent growth plates, E. coli colonies were not detected for 10, 20, and 31 water samples. However, they were detected by the mFC and/or Colilert methods. Thus, among the three methods tested, the MI method presented the lowest grow rate of atypic colonies and was the only one that presents no interference in the E. coli count.

  18. Use of Mueller-Hinton broth and agar in the germ tube test.

    PubMed

    Mattei, Antonella Souza; Alves, Sydney Hartz; Severo, Cecília Bittencourt; Guazzelli, Luciana da Silva; Oliveira, Flávio de Mattos; Severo, Luiz Carlos

    2014-01-01

    Candida albicans is often isolated from clinical samples, thus its presumptive differentiation from other species of the same genus can be based on its ability to form the germ tube in human serum. Nevertheless, there are two other species that share this characteristic: C. dubliniensis and C. africana. The aim of this study was to compare four different substrates to perform the germ tube (GT) test. The Candida spp. isolates were identified using a manual system (135 C. albicans, 24 C. tropicalis and one C. dubliniensis). The germ tube test was performed with fresh, previously frozen serum and Mueller-Hinton (MH) broth and agar. GT was observed in 96% (130/136) of the isolates through the fresh serum technique, 94% (128/136) through previously frozen serum, 92% (125/136) in MH agar, and 90% (122/136) in MH broth. The sensitivity of each test was higher than 90%, with 100% specificity. Both the MH agar and broth were able to identify the true positives, and false positives were not found. However, some C. albicans isolates were not identified. MH agar and broth may be used in laboratory for the rapid presumptive identification of C. albicans, as an alternative method for germ tube test.

  19. Rapid diagnosis of acanthamoeba keratitis using non-nutrient agar with a lawn of E. coli

    PubMed Central

    2013-01-01

    Background A patient presented with a corneal foreign body in his only eye. He was treated with prophylactic antibiotics and sent home, but deteriorated. Findings He returned to the hospital 5 days later, and on slit-lamp examination, there was ciliary injection, corneal oedema and a 1 mm × 1 mm corneal abscess with mild anterior uveitis. Corneal scrapings were taken for culture on a non-nutrient agar with a lawn of Escherichia coli, on chocolate agar and on blood agar. He was treated with fortified gentamicin and cefazolin drops. He improved and was discharged 4 days after admission. On day 5, the culture results showed acanthamoeba. He was brought back to the hospital and treated with hourly chlorhexidine drops, ofloxacin six times daily and neomycin/dexamethasone drops once daily. On day 7, he was discharged to continue treatment at home, at which time his visual acuity in that eye was 6/9, and slit-lamp examination showed punctate keratitis and a stromal opacity with mild peripheral infiltration. Conclusions Culture on non-nutrient agar with a lawn of E. coli is a rapid, reliable and less invasive alternative to corneal biopsy for the diagnosis of acanthamoeba infection. We suggest using this method where acanthamoeba is suspected. Owing to the risk of corneal abscess, orthokeratology should be avoided in an amblyopic patient or an only eye. Acanthamoeba infection may be masked by other eye diseases. PMID:23514313

  20. In vitro growth of bioactive nanostructured apatites via agar-gelatin hybrid hydrogel.

    PubMed

    Deng, Yi; Zhao, Xianghui; Zhou, Yongsheng; Zhu, Peizhi; Zhang, Li; Wei, Shicheng

    2013-12-01

    Biomimetic synthesis of bone-like carbonated apatite with good biocompatibility is a promising strategy for the development of novel biomaterials for bone engineering applications. Most research efforts have been focused on only protein-based or only polysaccharide-based template for synthesis of apatite minerals. To understand the cooperative roles of gelatin and polysaccharide playing in the biomineralization, agar hydrogel, gelatin and agar-gelatin hybrid hydrogel were respectively introduced as mineralization matrix for the in vitro growth of apatite in the study. It was shown that bundle-like carbonated apatite was successfully prepared in agar-gelatin hybrid hydrogel for the first time, through the interaction between apatite and matrix macromolecule under physiological temperature. Moreover, the in vitro biocompatibility of the prepared nanostructured apatite crystals was investigated using CCK-8 assay and alkaline phosphatase activity of osteoblast-like MC3T3-E1. Compared with HA synthesized by traditional method, the obtained apatite in agar-gelatin hybrid hydrogel could provide significantly higher cell viability and alkaline phosphatase activity. Through the study, we could better understand the role of gelatin and polysaccharide in bone formation process, and the product is a promising candidate to be used in bone tissue engineering.

  1. Use of agar/glycerol and agar/glycerol/water as a translucent brain simulant for ballistic testing.

    PubMed

    Falland-Cheung, Lisa; Waddell, J Neil; Lazarjan, Milad Soltanipour; Jermy, Mark C; Winter, Taylor; Tong, Darryl; Brunton, Paul A

    2017-01-01

    The suitability of agar/glycerol/water and agar/glycerol mixtures as brain simulants was investigated. Test specimens (n=15) (50x27×37mm) were fabricated for these different mixtures and conditioned to 12°C, 22°C, and 26°C prior to testing. For comparison, fresh deer brain specimens (n=20) were sourced and prepared to the same dimensions as the agar/glycerol(/water) mixtures and conditioned to 12°C and 37°C. High impact tests were carried out with a 0.22-caliber air rifle pellet and a high-speed camera was used to record the projectile as it passed through the specimens, allowing for energy loss and vertical displacement velocity calculation. Although the agar/glycerol/water mixture presented with similar vertical expansion and contraction of the specimens to the warm and cold deer brains, a two-fold decrease of the vertical expansion and contraction was noticed with the agar/glycerol specimens. Also considerably less extrusion of this mixture out of the exit and entry sides after specimen penetration was observed. Of the simulants tested, agar/glycerol/water was the most suitable brain simulant for ballistic testing and impact studies.

  2. Effect of storage at 4 degrees on prepared Salmonella/microsome test plates.

    PubMed

    Stanton, C A; Riley, S E; Garner, R C

    1984-09-01

    Salmonella/microsome soft-agar overlay ('Ames' test) plates were prepared using the previously published 'York' method. Plates treated with either added 3-methylcholanthrene (3MC) or 3,3'-dichlorobenzidine (DCB) and Aroclor-induced rat-liver S9 were stored at 4 degrees after preparation and removed at time intervals thereafter for incubation at 37 degrees. The number of 3MC-induced mutants in TA100 fell within 24 h of storage by 50% but then remained at this level until 96 h. Storage for a total of 336 h still showed some residual mono-oxygenase activity. On the other hand the ability to convert DCB to a mutagen for TA98 appeared to increase with storage, reaching a peak by 96 h. After this time the number of induced mutants fell until by 336 h the numbers were approximately equal to those plates which had not been stored in the cold.

  3. Factors influencing the accuracy of the plating method used to enumerate low numbers of viable micro-organisms in food.

    PubMed

    Jongenburger, I; Reij, M W; Boer, E P J; Gorris, L G M; Zwietering, M H

    2010-09-30

    This study aims to assess several factors that influence the accuracy of the plate count technique to estimate low numbers of micro-organisms in liquid and solid food. Concentrations around 10CFU/mL or 100CFU/g in the original sample, which can still be enumerated with the plate count technique, are considered as low numbers. The impact of low plate counts, technical errors, heterogeneity of contamination and singular versus duplicate plating were studied. Batches of liquid and powdered milk were artificially contaminated with various amounts of Cronobacter sakazakii strain ATCC 29544 to create batches with accurately known levels of contamination. After thoroughly mixing, these batches were extensively sampled and plated in duplicate. The coefficient of variation (CV) was calculated for samples from both batches of liquid and powdered product as a measure of the dispersion within the samples. The impact of technical errors and low plate counts were determined theoretically, experimentally, as well as with Monte Carlo simulations. CV-values for samples of liquid milk batches were found to be similar to their theoretical CV-values established by assuming Poisson distribution of the plate counts. However, CV-values of samples of powdered milk batches were approximately five times higher than their theoretical CV-values. In particular, powdered milk samples with low numbers of Cronobacter spp. showed much more dispersion than expected which was likely due to heterogeneity. The impact of technical errors was found to be less prominent than that of low plate counts or of heterogeneity. Considering the impact of low plate counts on accuracy, it would be advisable to keep to a lower limit for plate counts of 25 colonies/plate rather than to the currently advocated 10 colonies/plate. For a powdered product with a heterogeneous contamination, it is more accurate to use 10 plates for 10 individual samples than to use the same 10 plates for 5 samples plated in duplicate.

  4. Air-coupled method to investigate the lowest-order antisymmetric Lamb mode in stubbed and air-drilled phononic plates

    NASA Astrophysics Data System (ADS)

    Zhang, Dongbo; Zhao, Jinfeng; Bonello, Bernard; Li, Libing; Wei, Jianxin; Pan, Yongdong; Zhong, Zheng

    2016-08-01

    In this work, we applied a robust and fully air-coupled method to investigate the propagation of the lowest-order antisymmetric Lamb (A0) mode in both a stubbed and an air-drilled phononic-crystal (PC) plate. By measuring simply the radiative acoustic waves of A0 mode close to the plate surface, we observed the band gaps for the stubbed PC plate caused by either the local resonance or the Bragg scattering, in frequency ranges in good agreement with theoretical predictions. We measured then the complete band gap of A0 mode for the air-drilled PC plate, in good agreement with the band structures. Finally, we compared the measurements made using the air-coupled method with those obtained by the laser ultrasonic technique.

  5. Application of laser ranging and VLBI data to a study of plate tectonic driving forces. [finite element method

    NASA Technical Reports Server (NTRS)

    Solomon, S. C.

    1980-01-01

    The measurability of changes in plate driving or resistive forces associated with plate boundary earthquakes by laser rangefinding or VLBI is considered with emphasis on those aspects of plate forces that can be characterized by such measurements. Topics covered include: (1) analytic solutions for two dimensional stress diffusion in a plate following earthquake faulting on a finite fault; (2) two dimensional finite-element solutions for the global state of stress at the Earth's surface for possible plate driving forces; and (3) finite-element solutions for three dimensional stress diffusion in a viscoelastic Earth following earthquake faulting.

  6. Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate

    PubMed Central

    Jin, Lin; Guo, Jialiang; Guo, Junfei; Yin, Yingchao; Zhang, Yingze

    2016-01-01

    Background. The use of locking plates has gained popularity to treat proximal humeral fractures. However, the complication rates remain high. Biomechanical study suggested that subchondral screw-tip abutment significantly increased the stability of plant. We present a simple method to obtain the proper screw length through the depth gauge in elderly patients and compared the clinical effects with traditional measuring method. Methods. 40 patients were separated into two groups according to the two surgical methods: the probing method with depth gauge and the traditional measuring method. The intraoperative indexes and postoperative complications were recorded. The Constant and Murley score was used for the functional assessment in the 12th month. Results. Operative time and intraoperative blood loss indicated no statistical differences. X-ray exposure time and the patients with screw path penetrating the articular cartilage significantly differed. Postoperative complications and Constant and Murley score showed no statistical differences. Conclusions. Probing method with depth gauge is an appropriate alternative to determine the screw length, which can make the screw-tip adjoin the subchondral bone and keep the articular surface of humeral head intact and at the same time effectively avoid frequent X-ray fluoroscopy and adjusting the screws. PMID:27975055

  7. A vortex-lattice method in the linear theory on a two-dimensional supercavitating flat plate foil

    NASA Astrophysics Data System (ADS)

    Kida, T.; Take, T.

    1983-02-01

    The vortex-lattice method has been found very satisfactory in the case of steady subsonic wing theory, however, the discrete numerical methods, such as the vortex-lattice method, have not been studied in detail for supercavitating flows. One of the discrete numerical method, a vortex-lattice method, is developed in the present paper for cavitating flows around a two dimensional flat plate foil. The governing equations in the linear theory are represented as a set of coupled integral equations with Cauchy kernel, and there are unknown functions which are not under integral signs. For solving them, they are exchanged to an alternative set of coupled integral equations by a new variable, and the present vortex-lattice method is schemed for equal spacing of the vortices and sources in this new variable. The position of the collocation points is determined, and it is sufficient to treat unknown functions which are not integral signs as step functions. Moreover, the proof of the convergence of this method is shown and the accuracy is estimated.

  8. Effects of immersion disinfection of agar-alginate combined impressions on the surface properties of stone casts.

    PubMed

    Iwasaki, Yukiko; Hiraguchi, Hisako; Iwasaki, Eriko; Yoneyama, Takayuki

    2016-01-01

    This study investigated the effects of disinfection of agar-alginate combined impressions on the surface properties of the resulting stone casts. Two brands of cartridge-form agar impression material and one alginate impression material were used. Agar-alginate combined impressions of smooth glass plates were prepared. The impressions were immersed in 0.55% ortho-phthalaldehyde solution or 0.5% sodium hypochlorite solution for 1, 3, 5 and 10 min. A stone cast made with an impression that had not been immersed was prepared as a control. The surface roughness (Ra) of the stone casts was measured, and the cast surfaces were observed by SEM. Immersion of agar-alginate combined impressions in 0.5% sodium hypochlorite solution for up to 10 min had no serious adverse effects on the surface properties of the stone casts. In contrast, even 1 min of immersion in 0.55% ortho-phthalaldehyde solution caused deterioration of the cast surface properties.

  9. FRACTURES OF THE DISTAL EXTREMITY OF THE TIBIA TREATED WITH INTRAMEDULLARY NAIL OR BRIDGE PLATE: COMPARISON OF RADIATION EXPOSURE DURATION BETWEEN THE TWO METHODS

    PubMed Central

    Labronici, Pedro José; Lyra, Fábio Soares; Moreira, Ildeu Leite; Hoffmann, Rolix; Franco, José Sergio; de Toledo Lourenço, Paulo Roberto Barbosa; Labronici, Gustavo José

    2015-01-01

    Objective: To compare the duration of exposure to radiation among patients with fractures of the distal third of the tibia treated with an intramedullary nail or with a bridge plate. Methods: Intramedullary nails were used for 33 fractures, and bridge plates were used for 41 fractures. In the nail group, according to the AO classification, 14 patients had type A fractures, 15 had type B and four had type C. Twelve patients had closed fractures and 21 had open fractures. In the plate group, 10 patients had type A fractures, 22 had type B and nine had type C. Twenty-seven patients had closed fractures and 14 had open fractures. Results: There was a significant difference in the duration of exposure to radiation between the patients treated using a nail and those treated using a plate (p = 0.0001). The group treated using a nail had significantly greater exposure to radiation than did the group treated using a plate. Comparing the type of fracture (A, B or C), it was observed that there was no significant difference in the duration of exposure to radiation between the nail technique (p = 0.19) and the plate technique (p = 0.80). Conclusion: Fractures of the distal third of the tibia treated with an intramedullary nail present significantly greater exposure to radiation than do fractures treated with a bridge plate, independent of the fracture type. PMID:27022530

  10. Electrode Plate For An Eletrlchemical Cell And Having A Metal Foam Type Support, And A Method Of Obtaining Such An Electrode

    DOEpatents

    Verhoog, Roelof; Precigout, Claude; Stewart, Donald

    1996-05-21

    The electrode plate includes an active portion that is pasted with active material, and a plate head that is made up of three layers of compressed metal foam comprising: a non-pasted portion of height G of the support of the electrode plate; and two strips of non-pasted metal foam of height R on either side of the non-pasted portion of height G of the support and also extending for an overlap height h.sub.2 over the pasted portion of the support. The plate head includes a zone of reduced thickness including a portion that is maximally compressed, and a transitional portion between said maximally compressed portion and the remainder of the electrode which is of thickness e.sub.2. A portion of said plate head forms a connection tab. The method of obtaining the electrode consists in simultaneously rolling all three layers of metal foam in the plate head, and then in cutting matter away from the plates so as to obtain respective connection tabs.

  11. Primary plate identification of group A beta-hemolytic streptococci utilizing a two-disk technique.

    PubMed Central

    Baron, E J; Gates, J W

    1979-01-01

    A two-disk system is described which allows primary plate identification of group A beta-hemolytic streptococci. Group A beta-hemolytic streptococci could be visualized on primary throat culture plates by using trimethoprim-sulfamethoxazole to inhibit normal flora. In the heavily inoculated area of Trypticase soy agar plates containing 5% sheep blood, a 25-microgram/ml trimethoprim-sulfamethoxazole disk was placed contiguous to a 0.04-U bacitracin disk. A total of 259 throat specimens were examined with this two-disk system. The swabs from these throat specimens were incubated in Todd-Hewitt broth. The bacterial pellet from the broths was stained by fluorescent antibody as a control. Of the cultures that were determined to be positive on the plates, 75% could be read unequivocally after overnight incubation, whereas the remaining 25% required subculture. The plates recovered 91% of the cultures which were considered as true positives by the broth-fluorescent-antibody technique. This method provided a significant savings in time compared with standard plate methods and in cost of materials compared with broth-fluorescent-antibody methods. This technique is particularly valuable for producing rapid results in laboratories where fluorescence microscopy would not be cost-effective. Images PMID:387811

  12. Micro-agar salt bridge in patch-clamp electrode holder stabilizes electrode potentials

    PubMed Central

    Shao, Xuesi M.; Feldman, Jack L.

    2015-01-01

    Maintaining a stable electrode potential is critical for patch-clamp measurements. The electrode potential of conventional patch electrode-holder assembly, where an Ag/AgCl wire is in direct contact with the patch pipette filling solution, is subject to drift if the pipette solution contains a low concentration of chloride ions (Cl−). We developed an agar bridge of 3 M KCl filled in a polyimide microtubing which forms an electrical connection between an Ag/AgCl wire and the pipette solution. We examined the offset potentials of the micro-agar salt bridge electrode assembly in parallel with a conventional electrode assembly in generic recording conditions (the pipette solution contained 5 mM NaCl). The junction potential between the Ag/AgCl wire and the pipette filling solution in the conventional electrode contributed to most of the offset potential drift observed during the course of 30 min recordings. The drift was up to 27.3 mV after several changes of the glass pipette. In contrast, the micro-agar salt bridge stabilized the electrode potential within typically 2 mV without affecting the patch electrode resistance, capacitance or noise level. Numerical simulations showed that Cl− diffusion from the agar bridge to the tip caused a negligible 0.4 μM Cl− concentration change at the pipette tip within 30 min. This method is easy to implement and provides long-term recording stability. The micro-agar salt bridge can fit in most commercial patch electrode holders and can be conveniently maintained. PMID:16916545

  13. Effect of the Process Parameters on the Formability, Microstructure, and Mechanical Properties of Thin Plates Fabricated by Rheology Forging Process with Electromagnetic Stirring Method

    NASA Astrophysics Data System (ADS)

    Jin, Chul Kyu; Jang, Chang Hyun; Kang, Chung Gil

    2014-01-01

    A thin plate (150 × 150 × 1.2 mm) with embedded corrugation is fabricated using the rheoforming method. Semisolid slurry is created using the electromagnetic stirring (EMS) system, and the thin plate is made with the forging die at the 200-ton hydraulic press. The cross sections and microstructures of the slurry with and without stirring are examined. To investigate the effect of the process parameters on the formability, microstructure, and mechanical properties of thin plate the slurry is subjected to 16 types of condition for the forging experiment. The 16 types included the following conditions: Whether the EMS is applied or not, three fractions of the solid phase at 35, 45 and 55 pct; two compression velocities at 30 and 300 mm s-1; and four different compression pressures—100, 150, 200 and 250 MPa. The thin plate's formability is enhanced at higher punch velocity for compressing the slurry, and fine solid particles are uniformly distributed, which in turn, enhances the plate's mechanical properties. The pressure between 150 and 200 MPa is an appropriate condition to form thin plates. A thin plate without defects can be created when the slurry at 35 pct of the solid fraction (f s) was applied at the compression velocity of 300 mm s-1 and 150 MPa of pressure. The surface state of thin plate is excellent with 220 MPa of tensile strength and 13.5 pct of elongation. The primary particles are fine over the entire plate, and there are no liquid segregation-related defects.

  14. Stable semi-analytical method for analysis of plasmonic propagation on periodically patterned metal plates

    NASA Astrophysics Data System (ADS)

    Yasrebi, Navid; Khorasani, Sina; Karami-Taheri, Hossein; Rashidian, Bizhan; Hosseini, Amir

    2010-02-01

    The need for antennas with improved characteristics for communication and radar applications has resulted in an ever-increasing demand for research in the field of high impedance surfaces, which can work as an artificial magnetic conductor. One method in fabrication of these surfaces is formation of a metamaterial by patterning a metallic surface in the shape of space filling curves (e.g. Hilbert or Peanu Curves). In this paper, we present a novel semi-analytical solution to the problem of plasmonic propagation on these surfaces. The method is based on a previously presented Green's function formalism, which has been reported in an earlier paper of ours. We have modified and improved the method for analysis of periodic structures with a large number of spatial harmonics, and used different methods to get the necessary stabilization. Here propagating modes of different structures and their corresponding frequencies are calculated, and the possibility of frequency gap formation and stability of the method are investigated.

  15. Optical thickness measurement of mask blank glass plate by the excess fraction method using a wavelength-tuning interferometer

    NASA Astrophysics Data System (ADS)

    Kim, Yangjin; Hibino, Kenichi; Sugita, Naohiko; Mitsuishi, Mamoru

    2013-10-01

    The absolute optical thickness of a 140-mm2 mask blank glass plate 3.1 mm thickness was measured by three-surface interferometry using a wavelength-tuning Fizeau interferometer. The interference order was determined by the excess fraction method. The wavelength of a tunable laser diode was scanned linearly from 632 to 642 nm, and a CCD detector recorded 2000 interference images. Two kinds of optical thicknesses measured by discrete Fourier analysis and phase-shifting were synthesized to obtain the optical thickness with respect to the ordinary refractive index. The optical thickness defined by the group refractive index at the 637 nm central wavelength was measured by wavelength scanning. The optical thickness deviation defined by the ordinary refractive index was measured using tunable phase-shifting. The systematic errors caused by nonlinearity in the wavelength tuning were corrected through correlation analysis between the theoretical and observed interference fringes.

  16. Fly agaric (Amanita muscaria) poisoning, case report and review.

    PubMed

    Satora, Leszek; Pach, Dorota; Butryn, Beata; Hydzik, Piotr; Balicka-Slusarczyk, Barbara

    2005-06-01

    Gathering and eating mushrooms and other plants containing psychoactive substances has become increasingly popular among young people experimenting with drugs. Dried fly agaric Amanita muscaria fruiting bodies were eaten by five young persons (18-21 years of age) at a party in order to evoke hallucinations. Visual and auditory hallucinations occurred in four of them, whereas a 18-year-old girl lost consciousness. The following morning, she went to the Clinic of Toxicology. Due to the fact that not all the active substances present in the fly agaric have been identified, and some of them have an effect after a period of latency, the patient was admitted for several days of observation during which check-up examinations were performed. After four days without any problems, she was discharged. The poisoning regressed with no organ complications. The remaining persons who had eaten the fly agaric were free from any complaints.

  17. A Novel Method for Characterizing the Impact Response of Functionally Graded Plates

    DTIC Science & Technology

    2008-09-01

    the stress distribution is obtained through a superposition method (this technique is named the crack -compliance method, attributed to Prime [95]). The...Residual Stress Measurement by Successive Extension of a Slot: The Crack Compliance Method”. Applied Mechanics Review, 52(2):75–96, 1999. 96...struc- tural applications where extreme thermal and corrosion resistance are required. A proposed application for FGMs is the combination of exterior

  18. Thermodynamic equilibrium solubility measurements in simulated fluids by 96-well plate method in early drug discovery.

    PubMed

    Bharate, Sonali S; Vishwakarma, Ram A

    2015-04-01

    An early prediction of solubility in physiological media (PBS, SGF and SIF) is useful to predict qualitatively bioavailability and absorption of lead candidates. Despite of the availability of multiple solubility estimation methods, none of the reported method involves simplified fixed protocol for diverse set of compounds. Therefore, a simple and medium-throughput solubility estimation protocol is highly desirable during lead optimization stage. The present work introduces a rapid method for assessment of thermodynamic equilibrium solubility of compounds in aqueous media using 96-well microplate. The developed protocol is straightforward to set up and takes advantage of the sensitivity of UV spectroscopy. The compound, in stock solution in methanol, is introduced in microgram quantities into microplate wells followed by drying at an ambient temperature. Microplates were shaken upon addition of test media and the supernatant was analyzed by UV method. A plot of absorbance versus concentration of a sample provides saturation point, which is thermodynamic equilibrium solubility of a sample. The established protocol was validated using a large panel of commercially available drugs and with conventional miniaturized shake flask method (r(2)>0.84). Additionally, the statistically significant QSPR models were established using experimental solubility values of 52 compounds.

  19. Lysine-iron agar in the detection of Arizona cultures.

    PubMed

    EDWARDS, P R; FIFE, M A

    1961-11-01

    A lysine-iron agar is described and recommended for the detection of Arizona strains which ferment lactose rapidly. Black colonies which appear on bismuth sulfite agar should be transferred to the medium. Salmonellae and Arizona cultures produce a distinctive reaction since they are the only recognized groups of enteric bacteria which regularly produce lysine decarboxylase rapidly and form large amounts of hydrogen sulfide. Use of the medium is particularly recommended in the examination of specimens from enteric infections in which shigellae and salmonellae are not detected.

  20. A method for calculating strut and splitter plate noise in exit ducts: Theory and verification

    NASA Technical Reports Server (NTRS)

    Fink, M. R.

    1978-01-01

    Portions of a four-year analytical and experimental investigation relative to noise radiation from engine internal components in turbulent flow are summarized. Spectra measured for such airfoils over a range of chord, thickness ratio, flow velocity, and turbulence level were compared with predictions made by an available rigorous thin-airfoil analytical method. This analysis included the effects of flow compressibility and source noncompactness. Generally good agreement was obtained. This noise calculation method for isolated airfoils in turbulent flow was combined with a method for calculating transmission of sound through a subsonic exit duct and with an empirical far-field directivity shape. These three elements were checked separately and were individually shown to give close agreement with data. This combination provides a method for predicting engine internally generated aft-radiated noise from radial struts and stators, and annular splitter rings. Calculated sound power spectra, directivity, and acoustic pressure spectra were compared with the best available data. These data were for noise caused by a fan exit duct annular splitter ring, larger-chord stator blades, and turbine exit struts.

  1. Non-destructive method for inward leakage detection of a plate evaporator

    NASA Astrophysics Data System (ADS)

    Hribernik, Ales

    2007-05-01

    A new non-destructive method was developed for the detection of refrigerant leakage at an evaporator's inflow. Nitrogen and oxygen gas were successively blown through the evaporator. A gas analyser was applied at the outflow of the evaporator and the oxygen concentration measured. It was possible to detect any leakage by investigating the oxygen concentration-time history diagram.

  2. A new chromogenic agar medium, chromID VRE, to screen for vancomycin-resistant Enterococcus faecium and Enterococcus faecalis.

    PubMed

    Ledeboer, Nathan A; Tibbetts, Robert J; Dunne, William M

    2007-12-01

    We compared the performance of a chromogenic agar medium chromID VRE (bioMérieux, Marcy-l'Etoile, France) designed to recover and identify vancomycin-resistant enterococci (VRE) from clinical specimens with bile esculin azide vancomycin (BEAV) agar. For this study, 120 stool specimens were plated on chromID VRE and BEAV and examined after 24 and 48 h. At 24 h, the sensitivity and specificity were as follows: BEAV, 90.2% and 73%, respectively; chromID VRE, 86.3% and 100.0%, respectively. Furthermore, we determined that the sensitivity and specificity of chromID VRE for Enterococcus faecium were 85.4% and 100%, respectively, and for Enterococcus faecalis, 90% and 100%, respectively. We conclude that chromID VRE provides an equivalent sensitivity for the recovery of VRE from stool specimens, with improved specificity, and the added advantage of providing differentiation between vancomycin-resistant E. faecium and E. faecalis.

  3. Quantitative Laser Biospeckle Method for the Evaluation of the Activity of Trypanosoma cruzi Using VDRL Plates and Digital Analysis

    PubMed Central

    Grassi, Hilda Cristina; García, Lisbette C.; Lobo-Sulbarán, María Lorena; Velásquez, Ana; Andrades-Grassi, Francisco A.; Cabrera, Humberto; Andrades-Grassi, Jesús E.; Andrades, Efrén D. J.

    2016-01-01

    In this paper we report a quantitative laser Biospeckle method using VDRL plates to monitor the activity of Trypanosoma cruzi and the calibration conditions including three image processing algorithms and three programs (ImageJ and two programs designed in this work). Benznidazole was used as a test drug. Variable volume (constant density) and variable density (constant volume) were used for the quantitative evaluation of parasite activity in calibrated wells of the VDRL plate. The desiccation process within the well was monitored as a function of volume and of the activity of the Biospeckle pattern of the parasites as well as the quantitative effect of the surface parasite quantity (proportion of the object’s plane). A statistical analysis was performed with ANOVA, Tukey post hoc and Descriptive Statistics using R and R Commander. Conditions of volume (100μl) and parasite density (2-4x104 parasites/well, in exponential growth phase), assay time (up to 204min), frame number (11 frames), algorithm and program (RCommander/SAGA) for image processing were selected to test the effect of variable concentrations of benznidazole (0.0195 to 20μg/mL / 0.075 to 76.8μM) at various times (1, 61, 128 and 204min) on the activity of the Biospeckle pattern. The flat wells of the VDRL plate were found to be suitable for the quantitative calibration of the activity of Trypanosoma cruzi using the appropriate algorithm and program. Under these conditions, benznidazole produces at 1min an instantaneous effect on the activity of the Biospeckle pattern of T. cruzi, which remains with a similar profile up to 1 hour. A second effect which is dependent on concentrations above 1.25μg/mL and is statistically different from the effect at lower concentrations causes a decrease in the activity of the Biospeckle pattern. This effect is better detected after 1 hour of drug action. This behavior may be explained by an instantaneous effect on a membrane protein of Trypanosoma cruzi that could

  4. Stacking sequence and shape optimization of laminated composite plates via a level-set method

    NASA Astrophysics Data System (ADS)

    Allaire, G.; Delgado, G.

    2016-12-01

    We consider the optimal design of composite laminates by allowing a variable stacking sequence and in-plane shape of each ply. In order to optimize both variables we rely on a decomposition technique which aggregates the constraints into one unique constraint margin function. Thanks to this approach, an exactly equivalent bi-level optimization problem is established. This problem is made up of an inner level represented by the combinatorial optimization of the stacking sequence and an outer level represented by the topology and geometry optimization of each ply. We propose for the stacking sequence optimization an outer approximation method which iteratively solves a set of mixed integer linear problems associated to the evaluation of the constraint margin function. For the topology optimization of each ply, we lean on the level set method for the description of the interfaces and the Hadamard method for boundary variations by means of the computation of the shape gradient. Numerical experiments are performed on an aeronautic test case where the weight is minimized subject to different mechanical constraints, namely compliance, reserve factor and buckling load.

  5. Direct numerical simulation methods of hypersonic flat-plate boundary layer in thermally perfect gas

    NASA Astrophysics Data System (ADS)

    Jia, WenLi; Cao, Wei

    2014-01-01

    High-temperature effects alter the physical and transport properties of air such as vibrational excitation in a thermally perfect gas, and this factor should be considered in order to compute the flow field correctly. Herein, for the thermally perfect gas, a simple method of direct numerical simulation on flat-plat boundary layer is put forward, using the equivalent specific heat ratio instead of constant specific heat ratio in the N-S equations and flux splitting form of a calorically perfect gas. The results calculated by the new method are consistent with that by solving the N-S equations of a thermally perfect gas directly. The mean flow has the similarity, and consistent to the corresponding Blasius solution, which confirms that satisfactory results can be obtained basing on the Blasius solution as the mean flow directly in stability analysis. The amplitude growth curve of small disturbance is introduced at the inlet by using direct numerical simulation, which is consistent with that obtained by linear stability theory. It verified that the equation established and the simulation method is correct.

  6. Development of a Flow Cytometry-Based Method for Rapid Detection of Escherichia coli and Shigella Spp. Using an Oligonucleotide Probe

    PubMed Central

    Xue, Yong; Wilkes, Jon G.; Moskal, Ted J.; Williams, Anna J.; Cooper, Willie M.; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A.

    2016-01-01

    Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts. PMID:26913737

  7. Abolition of Swarming of Proteus by p-Nitrophenyl Glycerin: Application to Blood Agar Media

    PubMed Central

    Williams, Fred D.

    1973-01-01

    Comparative plate counts were made of Staphylococcus aureus and Streptococcus pyogenes growing on blood agar supplemented with individual chemicals to abolish the swarming of Proteus. B-phenylethanol, sodium azide, and p-nitrophenyl glycerin (PNPG) were used as anti-swarm agents. Each anti-swarm agent effectively abolished swarming for 24 h, but azide failed to control swarming for longer periods of incubation. In addition, azide displayed growth inhibition towards the staphylococci and streptococci resulting in no hemolysis and reduced viable cell numbers with the streptococci. Phenylethanol showed reduced viable cell numbers with the streptococci and unreliable hemolytic reactions. At 0.1 to 0.3 mM, PNPG proved to be a superior anti-swarm agent in that it showed no growth inhibition and allowed normal hemolysis, but abolished swarming for extended periods of time. When laboratory strains of Streptococcus pneumoniae, Klebsiella pneumoniae, Pseudomonas aeruginosa. Listeria monocytogenes, and Vibrio cholerae were screened on a blood agar medium containing 0.1 mm PNPG, they displayed similar growth and hemolytic characteristics to the identical medium without PNPG. PMID:4715553

  8. Inoculation of culture plates: straightforward or is it?

    PubMed

    Carlin, E M; Hammond, J A; Boag, F C

    1997-04-01

    In view of the recent vogue in some genitourinary medicine (GUM) units towards selective microscopy we aimed to assess the adequacy of culture plate inoculation in our own GUM clinic by the visual examination of 350 consecutively inoculated plates. Seventy-five (21%) plates were inoculated so lightly that no indentation in the agar could be seen whilst in 20 (60%) the agar was shredded. Eighty-five per cent of inadequately plated samples were inoculated by the same staff members who were either relatively inexperienced, or well-distanced from their last in-service training. This has many important implications not only in the identification and control of infection but also with respect to staff training. We have now introduced practical plating instruction for all new members of clinical staff and additional in-service training. We plan to repeat the audit in 6 months' time to assess the effect of these changes.

  9. Improved auxanographic method for yeast assimilations: a comparison with other approaches.

    PubMed Central

    Land, G A; Vinton, E C; Adcock, G B; Hopkins, J M

    1975-01-01

    An improved pour-plate auxanographic method has been developed for determining the assimilation of 14 different carbohydrates by medically important yeasts. Reduction of a dye incorporated into the agar has been correlated with the growth and carbohydrate assimilation of the yeasts, allowing the speciation of many yeasts within 24 to 48 h. This technique has been found to compare more than favorably with existing yeast assimilation techniques, in terms of rapid identification, total cost, and technician time in preparing and inoculating the plates. The dye pour-plate auxanographic technique provides an easier-to-interpret, rapid, and reproducible method of mycological identification for small clinical laboratories. Images PMID:1176628

  10. Reconstructing mantle heterogeneity with data assimilation based on the back-and-forth nudging method: Implications for mantle-dynamic fitting of past plate motions

    NASA Astrophysics Data System (ADS)

    Glišović, Petar; Forte, Alessandro

    2016-04-01

    The paleo-distribution of density variations throughout the mantle is unknown. To address this question, we reconstruct 3-D mantle structure over the Cenozoic era using a data assimilation method that implements a new back-and-forth nudging algorithm. For this purpose, we employ convection models for a compressible and self-gravitating mantle that employ 3-D mantle structure derived from joint seismic-geodynamic tomography as a starting condition. These convection models are then integrated backwards in time and are required to match geologic estimates of past plate motions derived from marine magnetic data. Our implementation of the nudging algorithm limits the difference between a reconstruction (backward-in-time solution) and a prediction (forward-in-time solution) on over a sequence of 5-million-year time windows that span the Cenozoic. We find that forward integration of reconstructed mantle heterogeneity that is constrained to match past plate motions delivers relatively poor fits to the seismic-tomographic inference of present-day mantle heterogeneity in the upper mantle. We suggest that uncertainties in the past plate motions, related for example to plate reorganization episodes, could partly contribute to the poor match between predicted and observed present-day heterogeneity. We propose that convection models that allow tectonic plates to evolve freely in accord with the buoyancy forces and rheological structure in the mantle could provide additional constraints on geologic estimates of paleo-configurations of the major tectonic plates.

  11. Sub-Plate Overlap Code Documentation

    NASA Technical Reports Server (NTRS)

    Taff, L. G.; Bucciarelli, B.; Zarate, N.

    1997-01-01

    An expansion of the plate overlap method of astrometric data reduction to a single plate has been proposed and successfully tested. Each plate is (artificially) divided into sub-plates which can then be overlapped. This reduces the area of a 'plate' over which a plate model needs to accurately represent the relationship between measured coordinates and standard coordinates. Application is made to non-astrographic plates such as Schmidt plates and to wide-field astrographic plates. Indeed, the method is completely general and can be applied to any type of recording media.

  12. Agar disk diffusion (Bauer-Kirby) tests with various fastidious and nonfastidious reference (ATCC) strains: comparison of several agar media.

    PubMed

    Traub, W H; Leonhard, B

    1994-01-01

    Several agar media (Mueller-Hinton agar, MHA; diagnostic sensitivity test agar, DSTA; Schaedler agar, SchA; Todd-Hewitt agar with added yeast extract, THYA; Wilkins-Chalgren agar, WCA) were compared using the Bauer-Kirby agar disk diffusion test against six nonfastidious quality control strains: Staphylococcus aureus ATCC 25923 and ATCC 29213, Escherichia coli ATCC 25922 and ATCC 35218, Pseudomonas aeruginosa ATCC 27853, and Enterococcus faecalis ATCC 29212. MHA, DSTA, and THYA yielded essentially comparable inhibition zones. However, WCA and SchA antagonized cotrimoxazole and aminoglycoside antibiotics; furthermore, SchA antagonized polymyxin B, and both WCA and SchA antagonized imipenem against the P. aeruginosa strain, but not against the E. coli strains. Sheep blood-MHA (Bl-MHA), WCA, THYA, and DSTA were examined with Streptococcus pyogenes ATCC 19615, Streptococcus agalactiae ATCC 13813, and Streptococcus pneumoniae ATCC 6306. In comparison with Bl-MHA, both WCA and THYA yielded comparable inhibition zones against S. pyogenes; DSTA afforded suboptimal growth. DSTA yielded larger inhibition zones with the majority of antimicrobial drugs against S. agalactiae, whereas WCA and THYA enhanced the activity of oxacillin and penicillin G against this strain. S. pneumoniae strain ATCC 6306 grew well on Bl-MHA, yielded suboptimal growth on WCA and faint growth on THYA, and failed to grow on DSTA. Chocolate-supplemented sheep blood-MHA (CHOC-MHA) was compared with Haemophilus test medium (HTM), WCA with added NAD, and THYA with added hematin and NAD against Haemophilus influenzae strains ATCC 35056 and ATCC 49247. The activities of doxycycline and rifampin were enhanced against both strains by HTM, WCA+NAD, and THYA+hematin+NAD. Only WCA+NAD antagonized cotrimoxazole against both H. influenzae strains, an effect due to thymidine; however, HTM antagonized cotrimoxazole against S. aureus ATCC 25923 and E. coli ATCC 25922. It was concluded that Bl-MHA performed best for

  13. A new numerical technique of electric field determination within dielectric materials plate and cable using the TSM method

    NASA Astrophysics Data System (ADS)

    Belgaroui, E.; Guermazi, H.; Agnel, S.; Mlik, Y.; Toureille, A.

    2003-07-01

    In the frame of the thermal step method (TSM) used to characterize the space charge in dielectric materials, we present an original numerical technique for determining the electric field distribution in the bulk of a dielectric plate or cable. The first stage of our technique is the application of the finite element method (FEM) in order to find instantaneous distributions of temperature profiles. The calculation of the electric field distribution is based on these obtained profiles. During the stage of the determination, our mathematical treatment is based on the TSM charge q(t) in order to avoid numerical instabilities on the temperature derivatives. Therefore, we have transformed the integral equation for the TSM current I(t) used in previous works to an integral equation for the TSM charge q(t). The control of the instantaneous propagation of the thermal wave front, produced by submitting one face of the dielectric to a thermal step, and the application of Simpson's method to the integral equation of the TSM charge q(t), allow to determine the electric field distribution. The results of the electric field distribution are validated with those obtained in previous works. A good agreement and an improvement near the dielectric thickness boundaries are observed on these results. The numerical space charge density within the material is obtained by numerical derivation of the field according to Poisson's equation.

  14. Improving agar electrospinnability with choline-based deep eutectic solvents

    Technology Transfer Automated Retrieval System (TEKTRAN)

    One percent agar (% wt) was dissolved in the deep eutectic solvent (DES), (2-hydroxyethyl) trimethylammonium chloride/urea at a 1:2 molar ratio, and successfully electrospun into nanofibers. An existing electrospinning set-up, operated at 50 deg C, was adapted for use with an ethanol bath to collect...

  15. An improved agar medium for growth of Geobacillus thermoglucosidarius strains.

    PubMed

    Javed, M; Baghaei-Yazdi, N; Qin, W; Amartey, S

    2017-01-01

    Geobacillus species have potential applications in many biotechnological processes. They are fastidious in their vitamin and amino acid requirements. A new semi-defined agar medium (SDM) was developed which gave consistently high viable cell counts of various G. thermoglucosidasius strains (5×10(8)-6×10(8)cfu/ml) under aerobic conditions at 70°C.

  16. [Modification of the lysine-iron agar (author's transl)].

    PubMed

    Wauters, G

    1975-12-01

    The addition of L-phenylalanine to the lysine-iron agar described by Edwards and Fife ]1] allows a more valuable screening of the Proteus group based on its deamination properties. Some minor modifications of the indicator and thiosulfate content lead to improve and earlier recording of the results.

  17. Non-Reflecting Regions for Finite Difference Methods in Modeling of Elastic Wave Propagation in Plates

    NASA Technical Reports Server (NTRS)

    Kishoni, Doron; Taasan, Shlomo

    1994-01-01

    Solution of the wave equation using techniques such as finite difference or finite element methods can model elastic wave propagation in solids. This requires mapping the physical geometry into a computational domain whose size is governed by the size of the physical domain of interest and by the required resolution. This computational domain, in turn, dictates the computer memory requirements as well as the calculation time. Quite often, the physical region of interest is only a part of the whole physical body, and does not necessarily include all the physical boundaries. Reduction of the calculation domain requires positioning an artificial boundary or region where a physical boundary does not exist. It is important however that such a boundary, or region, will not affect the internal domain, i.e., it should not cause reflections that propagate back into the material. This paper concentrates on the issue of constructing such a boundary region.

  18. A comparison of plate assay methods for detecting extracellular cellulase and xylanase activity.

    PubMed

    Meddeb-Mouelhi, Fatma; Moisan, Jessica Kelly; Beauregard, Marc

    2014-11-01

    Identification of microorganisms for the production of carbohydrolytic enzymes is extremely important given the increased demand for these enzymes in many industries. To this end, dye-polysaccharide interactions which provide a visual indication of polymer hydrolysis (clear zones or halos) have been used for decades. For the detection of extracellular cellulase or xylanase activity many laboratories use Gram's iodine as the chromogenic dye, as it is a more rapid initial screening method compared to the use of other dyes. Here, we compared Gram's iodine and Congo red as indicators of polysaccharide hydrolysis. We attempted to detect cellulase activity using carboxymethylcellulose, and xylanase activity using birchwood xylan, in fourteen uncharacterized bacteria isolated from wood chips. Our results indicate that Gram's iodine may lead to identification of false positives in a typical screening protocol and that Congo red allows for avoidance of such pitfall. Congo red allowed detection of cellulase activity from live microbial colonies but not Gram's iodine. To confirm this, detection of enzymatic activity was also assessed using cell-free enzyme preparations. Congo red was found to be reliable in detecting cellulase activity with isolated enzymes preparations. Under the same conditions, neither of these dyes detected xylanase activity, despite independent evidence of xylanase activity for one of the preparations. We detected xylanase activity for this particular enzyme preparation using a coloured derivative of xylan (Remazol Brillant Blue R-xylan adduct) that respond to xylan hydrolysis. Our results suggest that methods that rely on interactions between a dye (Congo red or Gram's iodine) and a polymeric substrate (carboxymethylcellulose or birchwood xylan) for indirect detection of hydrolysis may require the use of relevant controls and independent confirmation of enzymatic activities.

  19. Phene Plate (PhP) biochemical fingerprinting. A screening method for epidemiological typing of enterococcal isolates.

    PubMed

    Saeedi, B; Tärnberg, M; Gill, H; Hällgren, A; Jonasson, J; Nilsson, L E; Isaksson, B; Kühn, I; Hanberger, H

    2005-09-01

    Pulsed-field gel electrophoresis (PFGE) is currently considered the gold standard for genotyping of enterococci. However, PFGE is both expensive and time-consuming. The purpose of this study was to investigate whether the PhP system can be used as a reliable clinical screening method for detection of genetically related isolates of enterococci. If so, it should be possible to minimize the number of isolates subjected to PFGE typing, which would save time and money. Ninety-nine clinical enterococcal isolates were analysed by PhP (similarity levels 0.90-0.975) and PFGE (similarity levels < or =3 and < or =6 bands) and all possible pairs of isolates were cross-classified as matched or mismatched. We found that the probability that a pair of isolates (A and B) belonging to the same type according to PhP also belong to the same cluster according to PFGE, i.e. p(A(PFGE)=B(PFGE) * A(PhP)=B(PhP)), and the probability that a pair of isolates of different types according to PhP also belong to different clusters according to PFGE, i.e. p(A(PFGE) not equalB(PFGE) * A(PhP) not equalB(PhP)), was relatively high for E. faecalis (0.86 and 0.96, respectively), but was lower for E. faecium (0.51 and 0.77, respectively). The concordance which shows the probability that PhP and PFGE agree on match or mismatch was 86%-93% for E. faecalis and 54%-66% for E. faecium, which indicates that the PhP method may be useful for epidemiological typing of E. faecalis in the current settings but not for E. faecium.

  20. A new method for analytical solution of inplane free vibration of rectangular orthotropic plates based on the analysis of infinite systems

    NASA Astrophysics Data System (ADS)

    Papkov, S. O.

    2016-05-01

    In this paper, a new method for in-plane free vibration analysis of rectangular orthotropic plate is presented. The cases for completely clamped and completely free plates are considered in detail. The boundary value problem is essentially reduced to infinite systems of linear algebraic equations. New mathematical theory and associated results are presented for investigating the asymptotic behavior of non-trivial solution of quasi-regular infinite system. By enhancing the theory, an effective and accurate algorithm for determining the natural frequencies and modes shapes vibrations is developed. The accuracy and computational efficiency of the method are demonstrated by examples.

  1. RAPA: a novel in vitro method to evaluate anti-bacterial skin cleansing products.

    PubMed

    Ansari, S A; Gafur, R B; Jones, K; Espada, L A; Polefka, T G

    2010-04-01

    Development of efficacious anti-bacterial skin cleansing products has been limited by the availability of a pre-clinical (in vitro) method to predict clinical efficacy adequately. We report a simple and rapid method, designated as rapid agar plate assay (RAPA), that uses the bacteriological agar surface as a surrogate substrate for skin and combines elements of two widely used in vivo (clinical) methods (Agar Patch and Cup Scrub). To simulate the washing of the human hand or forearm skin with the test product, trypticase soy agar plates were directly washed with the test product and rinsed under running tap water. After air-drying the washed plates, test bacteria (Staphylococcus aureus or Escherichia coli) were applied and the plates were incubated at 37 degrees C for 18-24 h. Using S. aureus as the test organism, anti-bacterial bar soap containing triclocarbanilide showed a strong linear relationship (R(2) = 0.97) between bacterial dose and their per cent reduction. A similar dose-response relationship (R(2) = 0.96) was observed for anti-bacterial liquid hand soap against E. coli. RAPA was able to distinguish between anti-bacterial products based on the nature and level of actives in them. In limited comparative tests, results obtained by RAPA were comparable with the results obtained by clinical agar patch and clinical cup scrub methods. In conclusion, RAPA provides a simple, rugged and reproducible in vitro method for testing the relative efficacy of anti-bacterial skin cleansing products with a likelihood of comparable clinical efficacy. Further testing is warranted to improve the clinical predictability of this method.

  2. Comparison of commercially available kits with standard methods for the detection of coliforms and Escherichia coli in foods.

    PubMed Central

    Venkateswaran, K; Murakoshi, A; Satake, M

    1996-01-01

    Three commercially available kits that were supplemented with substrates for enzyme reactions were evaluated to determine their abilities to detect coliforms and fecal coliforms in foods. Japanese and U.S. Food and Drug Administration standard methods, as well as two agar plate methods, were compared with the three commercial kits. A total of 50 food samples from various retailers were examined. The levels of detection of coliforms were high with the commercial kits (78 to 98%) compared with the levels of detection with the standard methods (80 to 83%) and the agar plate methods (56 to 83%). Among the kits tested, the Colilert kit had highest level of recovery of coliforms (98%), and the level of recovery of Escherichia coli as determined by beta-glucuronidase activity with the Colilert kit (83%) was comparable to the level of recovery obtained by the U.S. Food and Drug Administration method (87%). Isolation of E. coli on the basis of the beta-glucuronidase enzyme reaction was found to be good. Levine's eosine methylene blue agar, which has been widely used in various laboratories to isolate E. coli was compared with 4-methylumbelliferyl-beta-D-glucuronide (MUG)-supplemented agar for isolation of E. coli. Only 47% of the E. coli was detected when eosine methylene blue agar was used; however, when violet red bile (VRB)-MUG agar was used, the E. coli detection rate was twice as high. Of the 200 E. coli strains isolated, only 2 were found to be MUG negative, and the gene responsible for beta-glucuronidase activity (uidA gene) was detected by the PCR method in these 2 strains. Of the 90 false-positive strains isolated that exhibited various E. coli characteristic features, only 2 non-E.coli strains hydrolyzed MUG and produced fluorescent substrate in VRB-MUG agar. However, the PCR did not amplify uidA gene products in these VRB-MUG fluorescence-positive strains. PMID:8779561

  3. Evaluation of the spiral plating method for the enumeration of microorganisms throughout the manufacturing and ripening of a raw goat's milk cheese.

    PubMed

    Alonso-Calleja, Carlos; Carballo, Javier; Capita, Rosa; Bernardo, Ana; García-López, María Luisa

    2002-02-01

    A statistical comparison of the spiral plate count (SPLPC) and the standard plate count (SPC) methods for enumeration of microorganisms in raw goat's milk cheese throughout its manufacturing and ripening was carried out. Enumeration of mesophiles, lactic acid bacteria (presumptive lactococci, presumptive leuconostocs, and presumptive lactobacilli), Micrococcaceae, Enterobacteriaceae, and molds and yeasts was carried out for milk, curd, and 2-, 5-, 10-, 17-, and 27-day-old cheeses. Average counts for the SPLPC and SPC methods differed by less than half of a log cycle for all microbial groups studied (range of difference, -0.1386 [mesophiles] to +0.4397 [presumptive lactobacilli]). The results of the SPLPC method compared favorably with the results of the SPC procedure for mesophiles, presumptive lactococci, presumptive leuconostocs, Enterobacteriaceae, and molds and yeasts (the variance between replicate platings was close to 0.005, and correlation coefficients were >0.9). Correlation coefficients were lower for Micrococcaceae (r = 0.824) and presumptive lactobacilli (r = 0.670). Analysis of variance showed that the plating method was a significant factor (P < 0.05) for presumptive lactobacilli counts. In general, results from the SPLPC method compared favorably with results from SPC procedure in the enumeration of microorganisms in goat cheese throughout its manufacturingand ripening processes. However, the suitability of the SPLPC method depends mainly on the microbial group studied.

  4. Method of preparing a battery paste containing fibrous polyfluoroethylene for use in the plates of a lead-acid storage battery

    SciTech Connect

    Duddy, J.C.; Malaspina, F.P.; Martini, W.J.

    1982-02-16

    A method of preparing a battery paste for a lead-acid storage battery comprising: (A) mixing a water dispersion of polyfluoroethylene with lead material, (B) adding an aqueous solution of sulfuric acid to the lead material-dispersion mix and mixing to form a paste having fibrillation developed therein, (C) controlling the amount of fibrillation developed in the paste, and (D) controlling the paste density for use in a battery plate. The method provides an improved paste which permits substantial reduction in plate weights and density and loss of active material in the grid structure due to plate shedding over a conventional lead-acid paste. The saving in active material ranges from 10 to 30% over a conventional lead-acid paste without reduction in battery performance.

  5. Thermal-induced ageing of agar solutions: impact on the structural and mechanical properties of agar gels

    NASA Astrophysics Data System (ADS)

    Mao, Bosi; Bentaleb, Ahmed; Louerat, Frédéric; Divoux, Thibaut; Snabre, Patrick

    Numerous hydrogels are prepared by cooling down to ambient temperature, aqueous polymer solutions brought to a boil. Although the incubation time of the polymer solution at such a high temperature could be used as a tuning parameter, its impact on the subsequent gelation has been poorly investigated. Here we study the effect of prolonged heating at 80°C on a 1.5% wt solution of agar, a natural polysaccharide. The incubation time is varied from a few hours up to five days. We show that the agar sol. continuously degrades as the result of both the hydrolysis and the intermolecular oxidation of the polymer chains. Furthermore, electronic microscopy and X-ray diffraction experiments reveal that gels formed from older agar sols display an increasingly coarser microstructure composed of micron-sized aggregated pieces of polysaccharides, in contrast with the fibrous-like structure of gels made from fresh sols. Along with structural changes prolonged incubation time leads to weaker gels of lower shear elastic modulus. Finally, macro-indentation experiments coupled to direct visualization show that increasing the incubation time of the agar sol. decreases the yield strain of the gel by a factor of three, while the rupture scenario turns continuously from brittle to ductile-like. Acknowledging funding from BioMérieux & CNRS.

  6. Evaluation of Trans-Vag Broth, Colistin-Nalidixic Agar, and CHROMagar StrepB for Detection of Group B Streptococcus in Vaginal and Rectal Swabs from Pregnant Women in South Africa

    PubMed Central

    Kwatra, Gaurav; Madhi, Shabir A.; Cutland, Clare L.; Buchmann, Eckhart J.

    2013-01-01

    Maternal vaginal colonization with group B streptococcus (GBS) is a major risk factor for invasive GBS infection in newborns. The CDC-recommended method for detecting GBS colonization is to culture vaginal and rectal swabs in a selective broth followed by subculture on blood agar or a selective medium. A high incidence of antimicrobial resistance in the fecal microflora can compromise the recovery of GBS from the selective broth. Here, we compared CHROMagar StrepB (CA), Columbia colistin-nalidixic agar (CNA), and Trans-Vag selective broth enrichment for the isolation of GBS from 130 vaginal and 130 rectal swabs from pregnant women. The swabs were randomized for plating first on either CA or CNA, and they then were inoculated in Trans-Vag broth. GBS was cultured from 37.7% of the vaginal swabs and 33.1% of the rectal swabs. There were no differences in the detection rates for the vaginal swabs between CA (31.5%), CNA (26.2%), and the selective broth (30.0%). The sensitivities in relation to a composite score were 83.7%, 69.4%, and 79.6%, respectively. However, recovery of GBS from the rectal swabs was significantly higher from CA (29.2%; P < 0.0001) and CNA (23.8%; P = 0.002) than from the selective broth (9.2%). The sensitivities were 88.4%, 72.1%, and 27.9%, respectively. The order of plating on the solid medium was significant (P = 0.003), with GBS detection rates of 30.8% and 24.6% when swabs were plated first and second, respectively. These findings show that a selective broth is not suitable for the recovery of GBS from rectal swabs in settings such as ours, due to masking of the GBS colonies by persistent microflora. PMID:23698527

  7. Infrared thermography analysis of thermal diffusion induced by RF magnetic field on agar phantoms loaded with magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Bante-Guerra, Jose; Macías, J. D.; Caballero-Aguilar, L.; Vales-Pinzón, C.; Alvarado-Gil, J. J.

    2013-02-01

    Recently, several treatments for fighting malignant tumors have been designed. However these procedures have well known inconveniences, depending on their applicability, tumor size and side effects, among others. Magnetic hyperthermia is a safe, non-invasive method for cancer therapy. This treatment is applied via elevation of target tissue temperature by dissipation of heat from Magnetic Nanoparticles (MNPs), previously located within the tumor. The induction of heat causes cell death and therefore the removal of the tumor. In this work the thermal diffusion in phantoms of agar loaded with magnetic nanoparticles (MNPs) is studied using the infrared thermography technique, which is widely used in biology/medicine (e.g. skin temperature mapping). Agar is one of the materials used to simulate different types of body tissues, these samples are known as "phantoms". Agar is of natural origin, low cost and high degree of biocompatibility. In this work the agar gel was embedded with MNPs by coprecipitation and placed in an alternating magnetic field radiation. As a consequence, the energy from the radiation source is dissipated as heat and then transferred from the MNP to the gel, increasing its temperature. For the temperature analysis, the samples of agar gel were stimulated by RF magnetic field generated by coils. Heating was measured with infrared thermography using a Thermovision A20M infrared camera. Thermographic images allowed obtaining the dependence of thermal diffusion in the phantom as a function of the magnitude of the applied RF magnetic field and the load of magnetic particles.

  8. A simple modification of the Baermann method for diagnosis of strongyloidiasis.

    PubMed

    Hernández-Chavarría, F; Avendaño, L

    2001-08-01

    The diagnosis of Strongyloides stercoralis infections is routinely made by microscopic observation of larvae in stool samples, a low sensitivity method, or by other, most effective methods, such as the Baermann or agar culture plate methods. We propose in this paper a practical modification of Baermann method. One hundred and six stool samples from alcoholic patients were analyzed using the direct smear test, agar culture plate method, the standard Baermann method, and its proposed modification. For this modification the funnel used in the original version of the method is substituted by a test tube with a rubber stopper, perforated to allow insertion of a pipette tip. The tube with a fecal suspension is inverted over another tube containing 6 ml of saline solution and incubated at 37 degrees C for at least 2 h. The saline solution from the second tube is centrifuged and the pellet is observed microscopically. Larva of S. stercoralis were detected in six samples (5.7%) by the two versions of the Baermann method. Five samples were positive using the agar culture plate method, and only in two samples the larva were observed using direct microscopic observation of fecal smears. Cysts of Endolimax nana and Entamoeba histolytica/dyspar were also detected in the modification of Baermann method. Data obtained by the modified Baermann method suggest that this methodology may helps concentrate larvae of S. stercoralis as efficiently as the original method.

  9. Comparison of three thermographic post processing methods for the assessment of a repaired aluminum plate with composite patch

    NASA Astrophysics Data System (ADS)

    Daryabor, P.; Safizadeh, M. S.

    2016-11-01

    Composite patches are widely used to repair damaged metal structures, especially in aerospace industry. Perfect patch and bonding are necessary to achieve an effective repair. Various thermographic methods such as step heating thermography are commonly applied to inspect repaired structures. Since accurate determination of defect features are admirable, some techniques are used to process the thermal films. In this study, three common post processing techniques of thermography (namely, principle component analysis (PCA), pulse phase thermography (PPT) and thermal signal reconstruction (TSR)) have been utilized to inspect an aluminum plate repaired with carbon/epoxy patches. Several delaminations with various sizes and locations along with some disbond defects were artificially embedded in five samples of composite patches to experimentally investigate the performance of the three techniques for post-processing of the step heating thermography data. Furthermore, the outputs of the mentioned processing techniques were quantitatively compared to find the most effective one. Based on the comparison results, it was demonstrated that, TSR outputs leads to the more accurate defect sizing.

  10. A study of narrow gap laser welding for thick plates using the multi-layer and multi-pass method

    NASA Astrophysics Data System (ADS)

    Li, Ruoyang; Wang, Tianjiao; Wang, Chunming; Yan, Fei; Shao, Xinyu; Hu, Xiyuan; Li, Jianmin

    2014-12-01

    This paper details a new method that combines laser autogenous welding, laser wire filling welding and hybrid laser-GMAW welding to weld 30 mm thick plate using a multi-layer, multi-pass process. A “Y” shaped groove was used to create the joint. Research was also performed to optimize the groove size and the processing parameters. Laser autogenous welding is first used to create the backing weld. The lower, narrowest part of the groove is then welded using laser wire filling welding. Finally, the upper part of the groove is welded using laser-GMAW hybrid welding. Additionally, the wire feeding and droplet transfer behaviors are observed by high speed photography. The two main conclusions from this work are: the wire is often biased towards the side walls, resulting in a lack of fusion at the joint and the creation of other defects for larger groove sizes. Additionally, this results in the droplet transfer behavior becoming unstable, leading to a poor weld appearance for smaller groove sizes.

  11. Investigation of the Flow Structure on a Flat Plate Induced by Unsteady Plasma Actuation with DNS Methods

    NASA Astrophysics Data System (ADS)

    Yu, Jianyang; Chen, Fu; Liu, Huaping; Song, Yanping

    2015-12-01

    An investigation into the flow characteristic on a flat plate induced by an unsteady plasma was conducted with the methods of direct numerical simulations (DNS). A simplified model of dielectric barrier discharge (DBD) plasma was applied and its parameters were calibrated with the experimental results. In the simulations, effects of the actuation frequency on the flow were examined. The instantaneous flow parameters were also drawn to serve as a detailed study on the behavior when the plasma actuator was applied to the flow. The result shows that induced by the unsteady actuation, a series of vortex pairs which showed dipole formation and periodicity distribution were formed in the boundary layer. The production of these vortex pairs indicated a strong energy exchange between the main flow and the boundary layer. They moved downstream under the action of the free stream and decayed under the influence of the fluid viscosity. The distance of the neighboring vortices was found to be determined by the actuation frequency. Interaction of the neighboring vortices would be ignored when the actuation frequency was too small to make a difference. supported by the Foundation for Innovative Research Groups of National Natural Science Foundation of China (No. 51121004) and National Natural Science Foundation of China (No. 50976026)

  12. Reduction of astrometric plates

    NASA Technical Reports Server (NTRS)

    Stock, J.

    1984-01-01

    A rapid and accurate method for the reduction of comet or asteroid plates is described. Projection equations, scale length correction, rotation of coordinates, linearization, the search for additional reference stars, and the final solution are examined.

  13. How do microorganisms influence trace element uptake by plants? Screening in an agar model rhizosphere.

    NASA Astrophysics Data System (ADS)

    Marchetti, M.; Robinson, B. H.; Evangelou, M. W. H.; Vachey, A.; Schwitzguebel, J. P.; Bernier-Latmani, R.; Schulin, R.

    2009-04-01

    Trace elements (TE) are essential for humans and plants, but they may be toxic if their concentration is too high. For this reason, the management of TE in soils is very important. In some cases it may be necessary to increase the uptake of nutrients or TE by plants, for example in a biofortification perspective. Conversely, in some other cases TE uptake by plants should be decreased, for instance to avoid heavy metals entering the food chain via edible crops. Microorganisms living in the rhizosphere affect trace element (TE) uptake by plants. However, due to the complexity of this space and the variety of microorganisms that occur there, it is difficult to isolate the effect of any particular strain. To overcome this hurdle, we developed a system in which we grew plants under sterile conditions in agar and inoculated their rhizosphere with a single, well-defined microbial strain. For many years, agar has been used as a growth substrate for microorganisms and plant tissues. It is cheap, easy to use, and can be autoclaved to ensure its sterility. Because of its widespread use, an experiment conducted using this substrate can be reproduced under the same conditions in any laboratory. In contrast to soil, there is little interaction between the trace elements and the agar matrix. There are many studies investigating the influence of microorganisms on TE uptake by plants. However, so far only a small variety of microorganisms has been tested on few plant species. Therefore, the first objective of our research was to develop a method to rapidly screen a large variety of microorganisms on various plant species. Once this goal was achieved, we sought to study the effect of single, well-defined microbial strains on TE uptake by sunflower and wheat. The substrate for plants growth was a 10% agar solution prepared with modified Hoagland's solution and a TE solution containing 1 mg/kg Pb and molar equivalents of Cu, Ni and Zn. The agar solution was autoclaved and poured into

  14. A Method for Calculating the Induced Pressure Distribution Associated with a Jet in a Crossflow. M.S. Thesis; [for a flat plate

    NASA Technical Reports Server (NTRS)

    Dietz, W. E., Jr.

    1975-01-01

    A model is presented which can be used to study the loss of lift during hovering and horizontal flight of the VTOL aircraft. The model numerically predicts the pressure distribution induced by a round, turbulent, unheated, subsonic jet exhausting normally through a flat plate into a subsonic crossflow. The complete model assumes that the predominant features of the flow are jet entrainment and a pair of contrarotating vortices which form downstream of the jet. Experimentally determined vortex properties and a reasonable assumption concerning jet entrainment were used. Potential flow considerations were used except in the wake region, where a simple method for approximating the pressure distribution was suggested. The calculated pressure distribution, lift, and pitching moments on the flat plate are presented for a jet to crossflow velocity ratio of 8 and were compared with experimental results. A computer program is given which was used to calculate the pressure distribution across the flat plate.

  15. Agar-degrading bacteria isolated from Antarctic macroalgae.

    PubMed

    Alvarado, Roxana; Leiva, Sergio

    2017-03-10

    This study describes the taxonomic diversity of pigmented, agar-degrading bacteria isolated from the surface of macroalgae collected in King George Island, Antarctica. A total of 30 pigmented, agarolytic bacteria were isolated from the surface of the Antarctic macroalgae Adenocystis utricularis, Monostroma hariotii, Iridaea cordata, and Pantoneura plocamioides. Based on the 16S rRNA data, the agarolytic isolates were affiliated to the genera Algibacter, Arthrobacter, Brachybacterium, Cellulophaga, Citricoccus, Labedella, Microbacterium, Micrococcus, Salinibacterium, Sanguibacter, and Zobellia. Isolates phylogenetically related to Cellulophaga algicola showed the highest agarase activity in culture supernatants when tested at 4 and 37 °C. This is the first investigation of pigmented agar-degrading bacteria, members of microbial communities associated with Antarctic macroalgae, and the results suggest that they represent a potential source of cold-adapted agarases of possible biotechnological interest.

  16. Evaluation of a novel chromogenic agar medium for isolation and differentiation of vancomycin-resistant Enterococcus faecium and Enterococcus faecalis isolates.

    PubMed

    Ledeboer, Nathan A; Das, Kingshuk; Eveland, Michael; Roger-Dalbert, Céline; Mailler, Sandrine; Chatellier, Sonia; Dunne, William Michael

    2007-05-01

    The development of reliable and rapid methods for the identification of patients colonized with vancomycin-resistant enterococci (VRE) is central to the containment of this agent within a hospital environment. To this end, we evaluated a prototype chromogenic agar medium (VRE-BMX; bioMérieux, Marcy l'Etoile, France) used to recover VRE from clinical specimens. This medium can also identify isolated colonies as either vancomycin-resistant Enterococcus faecium or Enterococcus faecalis, based on distinct colony colors. We compared the performance of VRE-BMX with bile esculin azide agar supplemented with vancomycin (BEAV). For this study, 147 stool samples were plated on each test medium and examined after 24 and 48 h of incubation. At 24 h, the sensitivity and specificity of each medium were as follows: BEAV, 90.9% and 89.9%, respectively; VRE-BMX, 96.4% and 96.6%, respectively. The positive predictive values (PPV) of VRE-BMX and BEAV at 24 h were 89.8% and 80.7%, respectively. VRE-BMX provided the identification of 10 isolates of vancomycin-resistant E. faecalis and 4 isolates of vancomycin-resistant E. faecium that were not recovered by BEAV. Further, VRE-BMX was capable of identifying patients colonized with both E. faecium and E. faecalis, a feature useful for infection control purposes that is not a function of BEAV. In terms of the recovery of vancomycin-resistant E. faecium and E. faecalis, the sensitivity and PPV were as follows: BEAV, 75.7% and 74.6%, respectively; VRE-BMX, 95.5% and 91.3%, respectively. In this initial evaluation, we found that VRE-BMX provided improved recovery of VRE from stool specimens, with the added advantage of being able to differentiate between vancomycin-resistant E. faecalis and E. faecium. Extending the incubation period beyond 24 h did not significantly improve the recovery of VRE and resulted in decreased specificity.

  17. Characteristics of unerasable and reappearing photostimulated luminescence signals in over-irradiated imaging plates and a new complete erasing method

    NASA Astrophysics Data System (ADS)

    Ohuchi, Hiroko; Kondo, Yasuhiro

    2008-11-01

    Characteristics of unerasable and reappearing photostimulated luminescence (PSL) signals in an imaging plate (IP) made of europium-doped BaFBr were investigated. It has been empirically known that the phenomena are observed remarkably in IPs irradiated with X-ray doses exceeding 1 mGy. In these over-irradiated IPs, quite stable latent images remain unerasable after fully erasing with visible light and latent images reappear after a while, even after they seem to have been completely erased. The results showed that the amount of reappearing PSL signals was proportional to the delivered dose when irradiated at a fixed dose rate, and it was not dependent on dose rate when irradiated with a fixed dose. The effect of heat on unerasable and reappearing latent PSL signals was examined. Unerasable PSL signals almost disappeared under a temperature of 120 °C over 28 elapsed days; however, a long heating period has also caused deterioration in IP samples. In a study on the effect of light sources on PSL signals using halogen light and fluorescent light, it was found that ultraviolet light around 290 nm promoted the occurrence of reappearing PSL signals that could be easily erased with visible light. This indicates that electrons localized in short wavelengths can be excited optically by an atomic line of mercury and shifted towards longer wavelengths, around 633 nm, causing reappearing latent images. From this result, a new method to completely erase unerasable latent images, i.e., by simultaneously exposing IP samples with an ultraviolet light and a fluorescent light, has been developed. After repeated treatment by this method, unerasable latent images were completely erased without reappearing PSL signals.

  18. Beyond Agar: Gel Substrates with Improved Optical Clarity and Drug Efficiency and Reduced Autofluorescence for Microbial Growth Experiments

    PubMed Central

    McElfresh, Cameron; Wong, Lily R.

    2015-01-01

    Agar, a seaweed extract, has been the standard support matrix for microbial experiments for over a century. Recent developments in high-throughput genetic screens have created a need to reevaluate the suitability of agar for use as colony support, as modern robotic printing systems now routinely spot thousands of colonies within the area of a single microtiter plate. Identifying optimal biophysical, biochemical, and biological properties of the gel support matrix in these extreme experimental conditions is instrumental to achieving the best possible reproducibility and sensitivity. Here we systematically evaluate a range of gelling agents by using the yeast Saccharomyces cerevisiae as a model microbe. We find that carrageenan and Phytagel have superior optical clarity and reduced autofluorescence, crucial for high-resolution imaging and fluorescent reporter screens. Nutrient choice and use of refined Noble agar or pure agarose reduce the effective dose of numerous selective drugs by >50%, potentially enabling large cost savings in genetic screens. Using thousands of mutant yeast strains to compare colony growth between substrates, we found no evidence of significant growth or nutrient biases between gel substrates, indicating that researchers could freely pick and choose the optimal gel for their respective application and experimental condition. PMID:26070672

  19. Mupirocin-mucin agar for selective enumeration of Bifidobacterium bifidum.

    PubMed

    Pechar, Radko; Rada, Vojtech; Parafati, Lucia; Musilova, Sarka; Bunesova, Vera; Vlkova, Eva; Killer, Jiri; Mrazek, Jakub; Kmet, Vladimir; Svejstil, Roman

    2014-11-17

    Bifidobacterium bifidum is a bacterial species exclusively found in the human intestinal tract. This species is becoming increasingly popular as a probiotic organism added to lyophilized products. In this study, porcine mucin was used as the sole carbon source for the selective enumeration of B. bifidum in probiotic food additives. Thirty-six bifidobacterial strains were cultivated in broth with mucin. Only 13 strains of B. bifidum utilized the mucin to produce acids. B. bifidum was selectively enumerated in eight probiotic food supplements using agar (MM agar) containing mupirocin (100 mg/L) and mucin (20 g/L) as the sole carbon source. MM agar was fully selective if the B. bifidum species was presented together with Bifidobacterium animalis subsp. lactis, Bifidobacterium breve, and Bifidobacterium longum subsp. longum species and with lactic acid bacteria (lactobacilli, streptococci). Isolated strains of B. bifidum were identified using biochemical, PCR, MALDI-TOF procedures and 16S rRNA gene sequencing. The novel selective medium was also suitable for the isolation of B. bifidum strains from human fecal samples.

  20. Modeling development of inhibition zones in an agar diffusion bioassay.

    PubMed

    Chandrasekar, Vaishnavi; Knabel, Stephen J; Anantheswaran, Ramaswamy C

    2015-09-01

    A two-temperature agar diffusion bioassay is commonly used to quantify the concentration of nisin using Micrococcus luteus as the indicator microorganism. A finite element computational model based on Fick's second law of diffusion was used to predict the radius of the inhibition zone in this diffusion bioassay. The model developed was used to calculate nisin concentration profiles as a function of time and position within the agar. The minimum inhibitory concentration (MIC) of nisin against M. luteus was determined experimentally. The critical time (T c) for growth of M. luteus within the agar diffusion bioassay was experimentally determined using incubation studies with nisin. The radius of the inhibition zone was predicted from the computational model as the location where the predicted nisin concentration at T c was equal to MIC. The MIC was experimentally determined to be 0.156 μg mL(-1), and T c was determined to be 7 h. Good agreement (R (2) = 0.984) was obtained between model-predicted and experimentally determined inhibition zone radii.

  1. A selective chromogenic agar that distinguishes Bacillus anthracis from Bacillus cereus and Bacillus thuringiensis.

    PubMed

    Juergensmeyer, Margaret A; Gingras, Bruce A; Restaino, Lawrence; Frampton, Elon W

    2006-08-01

    A selective and differential plating medium, R & F anthracis chromogenic agar (ACA), has been developed for isolating and identifying presumptive colonies of Bacillus anthracis. ACA contains the chromogenic substrate 5-bromo-4-chloro-3-indoxyl-choline phosphate that upon hydrolysis yields teal (blue green) colonies indicating the presence of phosphatidylcholine-specific phospholipase C (PC-PLC) activity. Among seven Bacillus species tested on ACA, only members of the Bacillus cereus group (B. anthracis, B. cereus, and B. thuringiensis) produced teal colonies (PC-PLC positive) having cream rings. Examination of colony morphology in 18 pure culture strains of B. anthracis (15 ATCC strains plus AMES-1-RIID, ANR-1, and AMED-RIID), with one exception, required 48 h at 35 to 37 degrees C for significant color production, whereas only 24 h was required for B. cereus and B. thuringiensis. This differential rate of PC-PLC synthesis in B. anthracis (due to the truncated plcR gene and PlcR regulator in B. anthracis) allowed for the rapid differentiation on ACA of presumptive colonies of B. anthracis from B. cereus and B. thuringiensis in both pure and mixed cultures. Effective recovery of B. anthracis from a variety of matrices having both high (soil and sewage) and low microbial backgrounds (cloth, paper, and blood) spiked with B. anthracis ANR-1 spores suggests the probable utility of ACA plating for B. anthracis recovery in a diversity of applications.

  2. Comparison of CHROMagar Salmonella Medium and Hektoen Enteric Agar for Isolation of Salmonellae from Stool Samples

    PubMed Central

    Gaillot, Olivier; Di Camillo, Patrick; Berche, Patrick; Courcol, René; Savage, Colette

    1999-01-01

    CHROMagar Salmonella (CAS), a new chromogenic medium, was retrospectively compared to Hektoen enteric agar (HEA) with 501 Salmonella stock isolates and was then prospectively compared to HEA for the detection and presumptive identification of Salmonella spp. with 508 stool samples before and after enrichment. All stock cultures (100%), including cultures of H2S-negative isolates, yielded typical mauve colonies on CAS, while 497 (99%) isolates produced typical lactose-negative, black-centered colonies on HEA. Following overnight incubation at 37°C, a total of 20 Salmonella strains were isolated from the 508 clinical samples. Sensitivities for primary plating and after enrichment were 95% (19 isolates) and 100% (20 isolates), respectively, for CAS and 80% (16 isolates) and 100% (20 isolates), respectively, for HEA. The specificity of CAS (88.9%) was significantly higher than that of HEA (78.5%; P < 0.0001). On the basis of its good sensitivity and specificity, CAS medium can be recommended for use for primary plating when human stool samples are screened for Salmonella spp. PMID:9986847

  3. Spray method for recovery of heat-injured Salmonella Typhimurium and Listeria monocytogenes.

    PubMed

    Back, Kyeong-Hwan; Kim, Sang-Oh; Park, Ki-Hwan; Chung, Myung-Sub; Kang, Dong-Hyun

    2012-10-01

    Selective agar is inadequate for supporting recovery of injured cells. During risk assessment of certain foods, both injured and noninjured cells must be enumerated. In this study, a new method (agar spray method) for recovering sublethally heat-injured microorganisms was developed and used for recovery of heat-injured Salmonella Typhimurium and Listeria monocytogenes. Molten selective agar was applied as an overlay to presolidified nonselective tryptic soy agar (TSA) by spray application. Heat-injured cells (55°C for 10 min in 0.1% peptone water or 55°C for 15 min in sterilized skim milk) were inoculated directly onto solidified TSA. After a 2-h incubation period for cell repair, selective agar was applied to the TSA surface with a sprayer, and the plates were incubated. The recovery rate for heat-injured Salmonella Typhimurium and L. monocytogenes with the spray method was compared with the corresponding rates associated with TSA alone, selective media alone, and the conventional overlay method (selective agar poured on top of resuscitated cells grown on TSA and incubated for 2 h). No significant differences (P > 0.05) were found in pathogen recovery obtained with TSA, the overlay method, and the spray method. However, a lower recovery rate (P < 0.05) was obtained for isolation of injured cells on selective media. Overall, these results indicate that the agar spray method is an acceptable alternative to the conventional overlay method and is a simpler and more convenient approach to recovery and detection of injured cells.

  4. Plane elasto-plastic analysis of v-notched plate under bending by boundary integral equation method. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Rzasnicki, W.

    1973-01-01

    A method of solution is presented, which, when applied to the elasto-plastic analysis of plates having a v-notch on one edge and subjected to pure bending, will produce stress and strain fields in much greater detail than presently available. Application of the boundary integral equation method results in two coupled Fredholm-type integral equations, subject to prescribed boundary conditions. These equations are replaced by a system of simultaneous algebraic equations and solved by a successive approximation method employing Prandtl-Reuss incremental plasticity relations. The method is first applied to number of elasto-static problems and the results compared with available solutions. Good agreement is obtained in all cases. The elasto-plastic analysis provides detailed stress and strain distributions for several cases of plates with various notch angles and notch depths. A strain hardening material is assumed and both plane strain and plane stress conditions are considered.

  5. Comparison of broth enhancement to direct plating for screening of rectal cultures for ciprofloxacin-resistant Escherichia coli.

    PubMed

    Liss, Michael A; Nakamura, Kristen K; Peterson, Ellena M

    2013-01-01

    A transrectal prostate biopsy is the most common procedure used to establish the diagnosis of prostate cancer. Prior to biopsy, patients are commonly given ciprofloxacin for prophylaxis. However, a complication of the procedure is infection with ciprofloxacin-resistant organisms, in particular resistant Escherichia coli. In order to identify patients carrying ciprofloxacin-resistant E. coli, so as to tailor their antibiotic prophylaxis, rectal swabs are screened using selective broth and/or solid medium. In our evaluation, we compared broth enrichment and direct plating techniques by using brain heart infusion broth and MacConkey agar containing 1 μg/ml or 10 μg/ml of ciprofloxacin. Of the 100 patients included in the study, 20 were colonized with ciprofloxacin-resistant organisms, 19 of which were E. coli. There was no significant difference (P > 0.1) between the culture methods or the ciprofloxacin concentrations in the medium when identifying patients with ciprofloxacin-resistant E. coli; however, broth enrichment using 1 μg/ml ciprofloxacin was the most sensitive at 100%, but it was the least specific. Direct plating of rectal swabs onto MacConkey agar containing 10 μg/ml of ciprofloxacin was 100% specific and missed only 1 positive specimen, with a sensitivity of 94.7%; this method was the most cost-effective. Therefore, direct plating of rectal swabs onto selective medium proved to be a sensitive and cost-effective approach in identifying patients colonized with ciprofloxacin-resistant E. coli.

  6. Peen plating

    NASA Technical Reports Server (NTRS)

    Babecki, A. J. (Inventor); Haehner, C. L.

    1973-01-01

    A process for metal plating which comprises spraying a mixture of metallic powder and small peening particles at high velocity against a surface is described. The velocity must be sufficient to impact and bond metallic powder onto the surface. In the case of metal surfaces, the process has as one of its advantages providing mechanical working (hardening) of the surface simultaneously with the metal plating.

  7. Combined Use of Pastorex Staph-Plus and Either of Two New Chromogenic Agars, MRSA ID and CHROMagar MRSA, for Detection of Methicillin-Resistant Staphylococcus aureus▿

    PubMed Central

    Compernolle, Veerle; Verschraegen, Gerda; Claeys, Geert

    2007-01-01

    We describe the search toward a fast and reliable strategy to detect and confirm the presence of methicillin-resistant Staphylococcus aureus (MRSA) in screening samples. First, we evaluated the sensitivities and specificities of oxacillin resistance screening agar (ORSA) with enrichment (tryptic soy broth [TSB] and ORSA [TSB-ORSA]) and without enrichment (ORSA), MRSA ID (MRSA_ID) plates, and CHROMagar MRSA (C_MRSA) plates, all of which were inoculated with equal volumes of a suspension made by emulsifying screening swabs. Whereas the sensitivities after 48 h were similar for all media tested (77% for MRSA_ID and ORSA; 73% for C_MRSA and ORSA after enrichment [TSB-ORSA]), the specificities of MRSA_ID (98% after 24 h and 94% after 48 h) and C_MRSA (98% after 24 h and 90% after 48 h) were superior to the specificities of ORSAs (92% after 24 h and 83% after 48 h) and TSB-ORSA (86% after 24 h and 81% after 48 h). Subsequently, the performance of the Pastorex Staph-Plus agglutination test with presumptive MRSA isolates taken directly from chromogenic agars (direct_Pastorex agglutination) was compared to that of the Pastorex Staph-Plus agglutination test with isolates from blood agar subcultures (conventional_Pastorex agglutination). When the direct_Pastorex agglutination test on MRSA_ID plates was combined with Gram staining, the direct_Pastorex agglutination test with samples from MRSA_ID plates was as reliable as the conventional_Pastorex agglutination test with samples from blood agar subcultures from MRSA_ID plates. In contrast, the direct_Pastorex agglutination test with samples from C_MRSA plates gave false-negative results. Finally, we calculated the processing times of the four different strategies, namely, (i) enrichment in TSB supplemented with NaCl, subsequent culture on ORSA, and the conventional_Pastorex agglutination test; (ii) direct inoculation of ORSA combined with conventional_Pastorex agglutination test; (iii) direct inoculation of MRSA_ID plates

  8. A highly efficient nonchemical method for isolating live nematodes (Caenorhabditis elegans) from soil during toxicity assays.

    PubMed

    Kim, Shin Woong; Moon, Jongmin; An, Youn-Joo

    2015-01-01

    The success of soil toxicity tests using Caenorhabditis elegans may depend in large part on recovering the organisms from the soil. However, it can be difficult to learn the International Organization for Standardization/ASTM International recovery process that uses the colloidal silica flotation method. The present study determined that a soil-agar isolation method provides a highly efficient and less technically demanding alternative to the colloidal silica flotation method. Test soil containing C. elegans was arranged on an agar plate in a donut shape, a linear shape, or a C curve; and microbial food was placed outside the soil to encourage the nematodes to leave the soil. The effects of ventilation and the presence of food on nematode recovery were tested to determine the optimal conditions for recovery. A linear arrangement of soil on an agar plate that was sprinkled with microbial food produced nearly 83% and 90% recovery of live nematodes over a 3-h and a 24-h period, respectively, without subjecting the nematodes to chemical stress. The method was tested using copper (II) chloride dihydrate, and the resulting recovery rate was comparable to that obtained using colloidal silica flotation. The soil-agar isolation method portrayed in the present study enables live nematodes to be isolated with minimal additional physicochemical stress, making it a valuable option for use in subsequent sublethal tests where live nematodes are required.

  9. Electrospinning of agar/PVA aqueous solutions and its relation with rheological properties

    Technology Transfer Automated Retrieval System (TEKTRAN)

    In this work, we report the successful fabrication of agar-based nanofibers by an electrospinning technique using water as the solvent media. A tubeless spinneret was attached inside the electrospinning chamber, operated at 50 deg C, to avoid agar gelation. Pure agar solution 1% (w/w) showed inadequ...

  10. Application of the Legendre wavelets method to the parallel plate flow of a third grade fluid and forced convection in a porous duct

    NASA Astrophysics Data System (ADS)

    Ali, N.; Ullah, Mati; Sajid, M.; Khan, S. U.

    2017-03-01

    A method based on Legendre wavelets is presented in this paper to discuss the flow of a third grade fluid between parallel plates and the forced convection in a porous duct. The flow problems are modeled in terms of integral equations which are then solved by the Legendre wavelets method. The comparison between present results and the existing solutions shows that the Legendre wavelets method is a powerful tool for solving nonlinear boundary value problems. We hope this method can be used for solving many interesting problems arising in non-Newtonian fluids.

  11. Philippine Sea and East Asian plate tectonics since 52 Ma constrained by new subducted slab reconstruction methods

    NASA Astrophysics Data System (ADS)

    Wu, Jonny; Suppe, John; Lu, Renqi; Kanda, Ravi

    2016-06-01

    We reconstructed Philippine Sea and East Asian plate tectonics since 52 Ma from 28 slabs mapped in 3-D from global tomography, with a subducted area of ~25% of present-day global oceanic lithosphere. Slab constraints include subducted parts of existing Pacific, Indian, and Philippine Sea oceans, plus wholly subducted proto-South China Sea and newly discovered "East Asian Sea." Mapped slabs were unfolded and restored to the Earth surface using three methodologies and input to globally consistent plate reconstructions. Important constraints include the following: (1) the Ryukyu slab is ~1000 km N-S, too short to account for ~20° Philippine Sea northward motion from paleolatitudes; (2) the Marianas-Pacific subduction zone was at its present location (±200 km) since 48 ± 10 Ma based on a >1000 km deep slab wall; (3) the 8000 × 2500 km East Asian Sea existed between the Pacific and Indian Oceans at 52 Ma based on lower mantle flat slabs; (4) the Caroline back-arc basin moved with the Pacific, based on the overlapping, coeval Caroline hot spot track. These new constraints allow two classes of Philippine Sea plate models, which we compared to paleomagnetic and geologic data. Our preferred model involves Philippine Sea nucleation above the Manus plume (0°/150°E) near the Pacific-East Asian Sea plate boundary. Large Philippine Sea westward motion and post-40 Ma maximum 80° clockwise rotation accompanied late Eocene-Oligocene collision with the Caroline/Pacific plate. The Philippine Sea moved northward post-25 Ma over the northern East Asian Sea, forming a northern Philippine Sea arc that collided with the SW Japan-Ryukyu margin in the Miocene (~20-14 Ma).

  12. Evaluation of the light scattering and the turbidity microtiter plate-based methods for the detection of the excipient-mediated drug precipitation inhibition.

    PubMed

    Petruševska, Marija; Urleb, Uroš; Peternel, Luka

    2013-11-01

    The excipient-mediated precipitation inhibition is classically determined by the quantification of the dissolved compound in the solution. In this study, two alternative approaches were evaluated, one is the light scattering (nephelometer) and other is the turbidity (plate reader) microtiter plate-based methods which are based on the quantification of the compound precipitate. Following the optimization of the nephelometer settings (beam focus, laser gain) and the experimental conditions, the screening of 23 excipients on the precipitation inhibition of poorly soluble fenofibrate and dipyridamole was performed. The light scattering method resulted in excellent correlation (r>0.91) between the calculated precipitation inhibitor parameters (PIPs) and the precipitation inhibition index (PI(classical)) obtained by the classical approach for fenofibrate and dipyridamole. Among the evaluated PIPs AUC100 (nephelometer) resulted in only four false positives and lack of false negatives. In the case of the turbidity-based method a good correlation of the PI(classical) was obtained for the PIP maximal optical density (OD(max), r=0.91), however, only for fenofibrate. In the case of the OD(max) (plate reader) five false positives and two false negatives were identified. In conclusion, the light scattering-based method outperformed the turbidity-based one and could be reliably used for identification of novel precipitation inhibitors.

  13. An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate

    NASA Astrophysics Data System (ADS)

    Nohtomi, Akihiro; Kurihara, Ryosuke; Kinoshita, Hiroyuki; Honda, Soichiro; Tokunaga, Masaaki; Uno, Heita; Shinsho, Kiyomitsu; Wakabayashi, Genichiro; Koba, Yusuke; Fukunaga, Junichi; Umezu, Yoshiyuki; Nakamura, Yasuhiko; Ohga, Saiji

    2016-10-01

    In our previous paper, the self-activation of an NaI scintillator had been successfully utilized for detecting photo-neutrons around a high-energy X-ray radiotherapy machine; individual optical pulses from the self-activated scintillator are read-out by photo sensors such as a photomultiplier tube (PMT). In the present work, preliminary observations have been performed in order to apply a direct CCD read-out technique to the self-activation method with a CsI scintillator plate using a Pu-Be source and a 10-MV linac. In conclusion, it has been revealed that the CCD read-out technique is applicable to neutron measurement around a high-energy X-ray radiotherapy machine with the self-activation of a CsI plate. Such application may provide a possibility of novel method for simple neutron dose-distribution measurement.

  14. Densitometric HPTLC method for qualitative, quantitative analysis and stability study of Coenzyme Q10 in pharmaceutical formulations utilizing normal and reversed-phase silica gel plates.

    PubMed

    Abdel-Kader, Maged Saad; Alam, Prawez; Alqasoumi, Saleh Ibrahim

    2016-03-01

    Two simple, precise and stability-indicating densitometric HPTLC method were developed and validated for qualitative and quantitative analysis of Coenzyme Q10 in pharmaceutical formulations using normal-phase (Method I) and reversed phase (Method II) silica gel TLC plates. Both methods were developed and validated with 10×20 cm glass-backed plates coated with 0.2 mm layers of either silica gel 60 F254 (E-Merck, Germany) using hexane-ethyl acetate (8.5:1.5 v/v) as developing system (Method I) or RP-18 silica gel 60 F254 (E-Merck, Germany) using methanol-acetone (4:6 v/v) as mobile phase (Method II). Both analyses were scanned with a densitometer at 282 nm. Linearity was found in the ranges 50-800 ng/spot (r(2)=0.9989) and 50-800 ng/spot (r(2)=0.9987) for Method I and Method II respectively. Stability of Coenzyme Q10 was explored by the two methods using acid, base, hydrogen peroxide, temperature and different solvents. Due to the efficiency of the method in separating Coenzyme Q10 from other ingredients including its degradation products, it can be applied for quality control, standardization of different pharmaceutical formulations and stability study.

  15. [The study of selecting sample detecting position and lead plate inner material in thin film method X-ray fluorescence measurement].

    PubMed

    Gan, Ting-ting; Zhang, Yu-jun; Zhao, Nan-jing; Yin, Gao-fang; Dong, Xin-xin; Wang, Ya-ping; Liu Jian-guo; Liu, Wen-qing

    2015-01-01

    (1) In this paper type 316 stainless steel metal plate as the research object, the selection of sample detecting position was studied when thin film method X-ray fluorescence measurement was conducted. The study showed that the optimal location for the sample detection was sample distance X-ray tube and detector baseline 1cm with the baseline into a 16°angle. (2) Heavy metal pollutants of Pb, Cd and Cr in industrial ambient air as the main analysis object, when thin film method X-ray fluorescence conducted with lead plate protection, X-rays will penetrate the membrane and continuely stimulate the protective lead plate. Therefore there is lead spectral line interference in the filter membrane background spectrum, which will affect the detection of lead element in real samples. Studies show that when a layer of isolating material was applied between the thin sample and the protective lead plate, the interference of lead line can effectively be avoided. (3) Several rigid insulating material of type 316 stainless steel, brass, aluminum, red copper and PTEE as lead inner material were selected and studied. The study results showed that compared with X-ray fluorescence spectra of other lead inner materials, the X-ray fluorescence spectrum of red copper contained the least element spectral lines. There were not Cr, Cd and Pb spectrum peaks in the X-ray fluorescence spectrum of red copper. And the target timber scattering spectrum intensity in the high energy part was weaker compared to other X-ray fluorescence spectrum. The above analysis shows that red copper has the minimal disturbance to the actual measurement of heavy metals Cr, Cd and Pb. At the same time, red copper as lead inner materials can effectively avoid the interference of lead spectrum line in lead plate. So red copper is the best lead plate inner materials in thin film method X-ray fluorescence spectroscopy measurement. This study provides an important theoretical basis for the assembling and setting

  16. A rapid, sensitive, simple plate assay for detection of microbial alginate lyase activity.

    PubMed

    Sawant, Shailesh S; Salunke, Bipinchandra K; Kim, Beom Soo

    2015-09-01

    Screening of microorganisms capable of producing alginate lyase enzyme is commonly carried out by investigating their abilities to grow on alginate-containing solid media plates and occurrence of a clearance zone after flooding the plates with agents such as 10% (w/v) cetyl pyridinium chloride (CPC), which can form complexes with alginate. Although the CPC method is good, advantageous, and routinely used, the agar in the media interferes with the action of CPC, which makes judgment about clearance zones very difficult. In addition, this method takes a minimum of 30 min to obtain the zone of hydrolysis after flooding and the hydrolyzed area is not sharply discernible. An improved plate assay is reported herein for the detection of extracellular alginate lyase production by microorganisms. In this method, alginate-containing agar plates are flooded with Gram's iodine instead of CPC. Gram's iodine forms a bluish black complex with alginate but not with hydrolyzed alginate, giving sharp, distinct zones around the alginate lyase producing microbial colonies within 2-3 min. Gram's iodine method was found to be more effective than the CPC method in terms of visualization and measurement of zone size. The alginate-lyase-activity area indicated using the Gram's iodine method was found to be larger than that indicated by the CPC method. Both methods (CPC and Gram's iodine) showed the largest alginate lyase activity area for Saccharophagus degradans (ATCC 43961) followed by Microbulbifer mangrovi (KCTC 23483), Bacillus cereus (KF801505) and Paracoccus sp. LL1 (KP288668) grown on minimal sea salt medium. The rate of growth and metabolite production in alginate-containing minimal sea salt liquid medium, followed trends similar to that of the zone activity areas for the four bacteria under study. These results suggested that the assay developed in this study of Gram's iodine could be useful to predict the potential of microorganisms to produce alginate lyase. The method also

  17. Performance comparison of flat plate collector absorber coatings utilizing NBS Standard 74-635 and the ASHRAE Collector Performance Method

    NASA Astrophysics Data System (ADS)

    Ingley, H. A.; Farber, E. A.; Reinhardt, R.

    Mildly selective (Chemglaze Z306 and Solarsorb C-1077 paints) surfaces, along with flat black paint and untreated copper, were evaluated as flat-plate solar collector coatings according to the National Bureau of Standards and the American Society of Heating, Refrigeration and Air Conditioning Engineers procedures for determining solar absorptivity. The moderately selective surfaces proved less efficient than flat black paint for operating temperatures less than 180 F. Highly selective (black chrome and copper oxide) surfaces, although tested, were not evaluated.

  18. Structural health monitoring method based on the entropy of an ultrasonic sensor network for a plate-like structure

    NASA Astrophysics Data System (ADS)

    Rojas, Erick; Baltazar, Arturo

    2015-03-01

    Piezoelectric ultrasonic sensors used to propagate guided waves can potentially be implemented to inspect large areas in engineering structures. However, the inherent dispersion and noise of the guided acoustic signals, multiple echoes in the plate as well as a lack of an approximate or exact model limits their use as a continuous structural health monitoring system. In this work, the implementation of a network of piezoelectric sensors randomly placed on a plate-like structure to detect and locate artificial damage is studied. A sensor network of randomly located 1MHz transducers working in a pitch-catch configuration was set on an aluminum thin plate 1.9 mm in thickness. Signals were analyzed in time-scale domain by the continuous wavelet transform. The objectives in this work were twofold, first to develop a damage index using the entropy of the ultrasonic waves generated by a sensor network; and second to implement time of arrival (TOA) and time-difference of arrival (TDOA) algorithms on the gathered signals for damage location of an artificial circular discontinuity. Our preliminary test results show that the proposed methodology provides sufficient information for damage detection which, once combined with the TOA and TDOA algorithms, allows localization of the damage.

  19. Bending and free vibration analysis of functionally graded plates using new eight-unknown shear deformation theory by finite-element method

    NASA Astrophysics Data System (ADS)

    Van Long, Nguyen; Quoc, Tran Huu; Tu, Tran Minh

    2016-12-01

    In this paper, a new eight-unknown shear deformation theory is developed for bending and free vibration analysis of functionally graded plates by finite-element method. The theory based on full 12-unknown higher order shear deformation theory simultaneously satisfies zeros transverse stresses at top and bottom surfaces of FG plates. A four-node rectangular element with 16 degrees of freedom per node is used. Poisson's ratios, Young's moduli, and material densities vary continuously in thickness direction according to the volume fraction of constituents which is modeled as power-law functions. Results are verified with available results in the literature. Parametric studies are performed for different power-law indices, side-to-thickness ratios.

  20. Hyperspectral imaging for differentiating colonies of non-O157 shiga-toxin producing echerichia coli (STEC) serogroups on spread plates of pure cultures

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Direct plating onto solid agar media has been widely used in microbiology laboratories for presumptive-positive pathogen detection in spite of the fact that it is often subjective, labor intensive and time consuming. Rainbow agar is a selective and chromogenic medium that helps to detect pathogenic ...

  1. Plating isolation of various catalase-negative microorganisms from soil

    NASA Technical Reports Server (NTRS)

    Labeda, D. P.; Hunt, C. M.; Casida, L. E., Jr.

    1974-01-01

    A unique plating procedure was developed that allows isolation, but not enumeration, of representatives of the catalase-negative soil microflora. The numbers recovered, however, are low as compared to the numbers recovered when the modified dilution-to-extinction isolation procedure is used. The latter procedure provides prolonged inoculation in sealed tubes containing a nutritionally rich broth medium over small submerged agar slants. In contrast, the plating procedure utilizes nutritionally minimal media and the shorter incubations mandated by the inherent problems associated with plating.

  2. Comparison of Petrifilm Staph Express Count System with the bacteriological analytical manual direct-plating method for enumeration of Staphylococcus aureus in artificially contaminated hard cheese.

    PubMed

    Fedio, Willis M; Wendakoon, Chitra N; Zapata, Ruben; Carrillo, Christina; Browning, Paul

    2008-01-01

    The 3M Petrifilm Staph Express Count System was compared with the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM) direct-plate count method for the enumeration of Staphylococcus aureus in 6 types of artificially contaminated hard cheese (Asiago, Cheddar, Gruyère, Parmesan, Romano, and Swiss). Five different samples of each cheese type were inoculated with S. aureus (ATCC 25923) to achieve low, medium, and high inoculum levels. S. aureus was enumerated by the Petrifilm and BAM methods, and the results were compared. Multivariate analysis of variance revealed no significant differences (P<0.05) between the 2 methods. The Petrifilm method compared favorably with the BAM procedure. The rapid method was more convenient to use, considerably faster, and less expensive to perform than the BAM method.

  3. Characterization of Leptospiral Chemoreceptors Using a Microscopic Agar Drop Assay.

    PubMed

    Affroze, Samia; Islam, Md Shafiqul; Takabe, Kyosuke; Kudo, Seishi; Nakamura, Shuichi

    2016-08-01

    Bacterial chemotaxis is induced by sensing chemical stimuli via chemoreceptors embedded in the cytoplasmic membrane, enabling the cells to migrate toward nutrients or away from toxins. The chemoreceptors of Escherichia coli and Salmonella spp. have been well studied and are functionally classified on the basis of detectable substrates. The spirochete Leptospira possesses more than ten chemoreceptors and shows attractive or repellent responses against some sugars, amino acids, and fatty acids. However, the roles of these chemoreceptors have not been investigated. In this study, we conducted a chemotaxis assay called microscopic agar drop assay in combination with competition experiments, determining whether two kinds of attractants are recognized by the same type of chemoreceptor in the saprophytic Leptospira strain, Leptospira biflexa. Analyzing the competition effect observed between several pairs of chemicals, we found that L. biflexa senses sugars via chemoreceptors different from those that sense amino acids and fatty acids.

  4. Surface migration of Staphylococcus xylosus on low-agar media.

    PubMed

    Dordet-Frisoni, Emilie; Gaillard-Martinie, Brigitte; Talon, Régine; Leroy, Sabine

    2008-05-01

    Staphylococcus xylosus is a commensal species commonly found on the skin of mammals, but also currently used as starter culture for meat fermentation. Most strains of this species colonize by forming a biofilm on abiotic surfaces. We show here that the majority of S. xylosus strains also exhibit extensive colony spreading on the surface of soft agar media. This phenomenon seemed to be independent of biofilm-forming ability. It occurred in different culture media and was dependent on temperature. Formation of a giant S. xylosus colony did not involve a biosurfactant. Microscopic observation showed that the front of the giant colony comprised a single layer of spacing cells with more packed cells in the median area. Supplementation of the soft media with DNase I increased S. xylosus colony spreading, indicating that extracellular DNA may be involved in limiting the phenomenon. The ability of S. xylosus to spread on semi-solid surfaces may constitute an advantage for surface colonization.

  5. UNIQUE METHOD FOR LIQUID NITROGEN PRECOOLING OF A PLATE FIN HEAT EXCHANGER IN A HELIUM REFRIGERATION CYCLE.

    SciTech Connect

    Weber, T

    2004-06-02

    Precooling of helium by means of liquid nitrogen is one the oldest and most common process features used in helium refrigerators. The principal tasks are to permit a rapid cool down to 80 K of the plant, to increase the cooling power of the plant in low temperature operation and to increase the rate of pure liquid production. The advent of aluminum plate fin heat exchangers in the design of helium refrigerators has made this task more complicated because of the potential damage to these heat exchangers.

  6. Plate electronics

    NASA Astrophysics Data System (ADS)

    Carlowicz, Michael

    Using a Cray T3D supercomputer and a simple assumption about the physical character of Earth's mantle, a pair of researchers from the University of California at Berkeley have built a computer model that may help explain why the planet's tectonic plates look the way they do.In creating a three-dimensional numerical simulation of convection in the Earth's interior, UC researchers Hans-Peter Bunge and Mark Richards simplified their model to account for just one major physical effect: that the viscosity of the mantle increases with depth. Reviewing some recent—but not yet widely accepted—seismic data, Bunge and Richards assumed for the sake of the model that the viscosity of the mantle increases by a factor of 30 from the lithosphere to the core-mantle boundary. Relying on that assumption, the pair ran the model for nearly three weeks on a supercomputer at Los Alamos National Laboratory and found that the simulation produced an effect similar to what we see on the surface of Earth. The model produced a surface paralleling the actual width of plates and the geometry of the plate boundaries.

  7. A Visualization Method for Corrosion Damage on Aluminum Plates Using an Nd:YAG Pulsed Laser Scanning System

    PubMed Central

    Lee, Inbok; Zhang, Aoqi; Lee, Changgil; Park, Seunghee

    2016-01-01

    This paper proposes a non-contact nondestructive evaluation (NDE) technique that uses laser-induced ultrasonic waves to visualize corrosion damage in aluminum alloy plate structures. The non-contact, pulsed-laser ultrasonic measurement system generates ultrasonic waves using a galvanometer-based Q-switched Nd:YAG laser and measures the ultrasonic waves using a piezoelectric (PZT) sensor. During scanning, a wavefield can be acquired by changing the excitation location of the laser point and measuring waves using the PZT sensor. The corrosion damage can be detected in the wavefield snapshots using the scattering characteristics of the waves that encounter corrosion. The structural damage is visualized by calculating the logarithmic values of the root mean square (RMS), with a weighting parameter to compensate for the attenuation caused by geometrical spreading and dispersion of the waves. An intact specimen is used to conduct a comparison with corrosion at different depths and sizes in other specimens. Both sides of the plate are scanned with the same scanning area to observe the effect of the location where corrosion has formed. The results show that the damage can be successfully visualized for almost all cases using the RMS-based functions, whether it formed on the front or back side. Also, the system is confirmed to have distinguished corroded areas at different depths. PMID:27999252

  8. A Visualization Method for Corrosion Damage on Aluminum Plates Using an Nd:YAG Pulsed Laser Scanning System.

    PubMed

    Lee, Inbok; Zhang, Aoqi; Lee, Changgil; Park, Seunghee

    2016-12-16

    This paper proposes a non-contact nondestructive evaluation (NDE) technique that uses laser-induced ultrasonic waves to visualize corrosion damage in aluminum alloy plate structures. The non-contact, pulsed-laser ultrasonic measurement system generates ultrasonic waves using a galvanometer-based Q-switched Nd:YAG laser and measures the ultrasonic waves using a piezoelectric (PZT) sensor. During scanning, a wavefield can be acquired by changing the excitation location of the laser point and measuring waves using the PZT sensor. The corrosion damage can be detected in the wavefield snapshots using the scattering characteristics of the waves that encounter corrosion. The structural damage is visualized by calculating the logarithmic values of the root mean square (RMS), with a weighting parameter to compensate for the attenuation caused by geometrical spreading and dispersion of the waves. An intact specimen is used to conduct a comparison with corrosion at different depths and sizes in other specimens. Both sides of the plate are scanned with the same scanning area to observe the effect of the location where corrosion has formed. The results show that the damage can be successfully visualized for almost all cases using the RMS-based functions, whether it formed on the front or back side. Also, the system is confirmed to have distinguished corroded areas at different depths.

  9. Comparison of CHROMagar Salmonella Medium and Xylose-Lysine-Desoxycholate and Salmonella-Shigella Agars for Isolation of Salmonella Strains from Stool Samples

    PubMed Central

    Maddocks, Susan; Olma, Tom; Chen, Sharon

    2002-01-01

    The growth and appearance of 115 stock Salmonella isolates on a new formulation of CHROMagar Salmonella (CAS) medium were compared to those on xylose-lysine-desoxycholate agar (XLD), Salmonella-Shigella agar (SS), and Hektoen enteric agar (HEA) media. CAS medium was then compared prospectively to XLD and SS for the detection and presumptive identification of Salmonella strains in 500 consecutive clinical stool samples. All stock Salmonella isolates produced typical mauve colonies on CAS medium. Nine Salmonella strains were isolated from clinical specimens. The sensitivities for the detection of salmonellae after primary plating on CAS medium and the combination of XLD and SS after enrichment were 100%. The specificity for the detection of salmonellae after primary plating on CAS medium (83%) was significantly (P < 0.0001) higher than that after primary plating on the combination of SS and XLD media (55%) (a 28% difference in rates; 95% confidence interval, 23.0 to 34%). Twenty-nine non-Salmonella organisms produced mauve colonies on CAS medium, including 17 Candida spp. (59%) and 8 Pseudomonas spp. (28%). These were easily excluded as salmonellae by colony morphology, microscopic examination of a wet preparation, or oxidase testing. One biochemically inert Escherichia coli isolate required further identification to differentiate it from Salmonella spp. The use of plating on CAS medium demonstrated high levels of sensitivity and specificity and reduced the time to final identification of Salmonella spp., resulting in substantial cost savings. It can be recommended for use for the primary isolation of Salmonella spp. from stool specimens. Other media (e.g., XLD) are required to detect Shigella spp. concurrently. PMID:12149365

  10. Evaluation of commercial selective agars in screening for methicillin-resistant Staphylococcus aureus.

    PubMed

    Yang, Hee-Young; Suh, Jin-Tae; Lee, Hee-Joo

    2010-01-01

    To evaluate methicillin-resistant S. aureus (MRSA) detection methods, we compared (a) mannitol salt agar with cefoxitin (MSA-FX), (b) MRSASelect agar (Bio-Rad), (c) MRSA ID (bioMerieuex), and (d) CHROMagar MRSA (BD Diagnostics) as selective media for culturing nasal swab specimens collected from intensive care unit (ICU) patients and healthcare personnel. A total of 99 (17.1%) cases of MRSA were recovered from 578 specimens. Four (5.5%) cases were identified from healthcare personnel and 95 (18.8%) were from ICU patients. The sensitivity of MSA-FX, MRSASelect, MRSA ID, and CHROMagar MRSA was 83.8, 87.9, 80.8, and 84.8% after 18 hr; 92.9, 94.9, 90.9, and 91.9% after 24 hr; and 96.0, 100, 99.0, and 99.0% after 48 hr, respectively. The specificity of MSA-FX, MRSASelect, MRSA ID, and CHROMagar MRSA was 97.7, 99.0, 98.7. and 99.8% after 18 hr; 97.1, 98.5, 98.1, and 99.5% after 24 hr; and 95.2, 97.7, 97.9, and 99.0% after 48 hr, respectively. In conclusion, all four media showed good results after the 24 hr readings, but MRSA ID and CHROMagar MRSA media required readings at 48 hr due to increased sensitivity at this time point.

  11. [Development of chromogenic agar medium for isolation of enterohaemorrhagic Escherichia coli O26].

    PubMed

    Ikedo, M; Komatsu, O; Hara-Kudo, Y; Yamamoto, S; Kumagai, S

    2001-04-01

    Agar media for isolation of enterohaemorrhagic Escherichia coli (EHEC) have been developed primarily for E. coli O157, because this bacterium has most frequently caused EHEC infection. However, there have been few studies for isolation of other serotypes of EHEC, and media appropriate for isolation of such organisms, especially from food samples, are not yet available. Among such serotypes, E. coli O26 has often been isolated from clinical specimens from patients and animals, but not from food samples in outbreaks, because of lack of an appropriate method for isolation. In this study, we tried to develop a new chromogenic agar medium for selective isolation of E. coli O26 using the characteristics of E. coli O26. Fifteen strains of E. coli O26, 11 strains of E. coli O157 and 36 strains of other sero-types E. coli were tested for fermentation of rhamnose, cellobiose, dulcitol, salicin, raffinose, sorbitol, sucrose, lactose, mannitol, arabinose, maltose, xylose and glucose. Rhamnose was fermented by all E. coli strains except for E. coli O26. The other substrates were not effective for differentiating E. coli O26 from the other strains of E. coli. Thus the medium containing rhamnose and 5-bromo-4-chloro-3-indolyl-beta-D-galactopyranoside, which is a substrate of beta-galactosidase specific to coliforms, produced a color of E. coli O26 colonies different from colors of the other bacteria. Furthermore, cefixime and sodium tellulite were added to the composition of the medium for gaining higher selectivity.

  12. An electrochemical approach to monitor pH change in agar media during plant tissue culture.

    PubMed

    Wang, Min; Ha, Yang

    2007-05-15

    In this work, metal oxide microelectrodes were developed to monitor pH change in agar media during plant tissue culture. An antimony wire was produced by a new approach "capillary melt method". The surface of the obtained antimony wire was oxidized in a potassium nitrate melt to fabricate an antimony oxide film for pH sensing. Characterization results show that the oxide layer grown on the wire surface consists of Sb(2)O(3) crystal phase. The sensing response, open-circuit potential, of the electrode has a good linear relationship (R(2)=1.00) with pH value of the test solution. Adding organic compounds into the test media would not affect the linear relationship, although the slope of the lines varied with different ingredients added. The antimony oxide electrodes were employed to continuously monitor pH change of agar culture media during a 2-week plant tissue culture of Dendrobium candidum. The antimony oxide electrode fabricated this way has the advantages of low cost, easy fabrication, fast response, and almost no contamination introduced into the system. It would be suitable for in situ and continuous pH measurement in many bio applications.

  13. US probes: risk of cross infection and ways to reduce it--comparison of cleaning methods.

    PubMed

    Fowler, C; McCracken, D

    1999-10-01

    After their use at ultrasonography (US) in the intensive therapy unit, probes were used to directly inoculate blood agar plates before and after various cleaning procedures. The uncleaned probes transmitted large numbers of clinically important microbes. Simple cleaning methods were effective in reducing transmission among certain patients: fit patients, double paper wipe; patients at risk of contracting infection, single paper wipe followed by alcohol wipe; patients with a potential source of infection, single paper wipe followed by alcohol wipe.

  14. Isolation of Shiga Toxin-Producing Escherichia coli from Ground Beef Using Multiple Combinations of Enrichment Broths and Selective Agars.

    PubMed

    Brusa, Victoria; Piñeyro, Pablo E; Galli, Lucía; Linares, Luciano H; Ortega, Emanuel E; Padola, Nora L; Leotta, Gerardo A

    2016-03-01

    Shiga toxin-producing Escherichia coli (STEC) are foodborne pathogens, and beef cattle are recognized as the principal reservoir. The aims of this study were (1) to identify the most sensitive combination of selective enrichment broths and agars for STEC isolation in artificially inoculated ground beef samples, and (2) to evaluate the most efficient combination(s) of methods for naturally contaminated ground beef samples. A total of 192 ground beef samples were artificially inoculated with STEC and non-stx bacterial strains. A combination of four enrichment broths and three agars were evaluated for sensitivity, specificity, and positive predictive value for STEC isolation from experimentally inoculated samples. Enrichments with either modified tryptic soy broth (mTSB) containing 8 mg/L novobiocin (mTSB-8) or modified Escherichia coli (mEC) broth followed by isolation in MacConkey agar were the most sensitive combinations for STEC isolation of artificially inoculated samples. Independently, both enrichments media followed by isolation in MacConkey were used to evaluate ground beef samples from 43 retail stores, yielding 65.1% and 58.1% stx-positive samples by RT-PCR, respectively. No difference was observed in the isolate proportions between these two methods (8/25 [32%] and 8/28 [28.6%]). Identical serotypes and stx genotypes were observed in STEC strains isolated from the same samples by either method. In this study, no single enrichment protocol was sufficient to detect all STEC in artificially inoculated samples and had considerable variation in detection ability with naturally contaminated samples. Moreover, none of the single or combinations of multiple isolation agars used were capable of identifying all STEC serogroups in either artificially inoculated or naturally occurring STEC-contaminated ground beef. Therefore, it may be prudent to conclude that there is no single method or combination of isolation methods capable of identifying all STEC serogroups.

  15. Comparison of spiral gradient and conventional agar dilution for susceptibility testing of anaerobic bacteria.

    PubMed Central

    Wexler, H M; Molitoris, E; Jashnian, F; Finegold, S M

    1991-01-01

    Antimicrobial susceptibility tests were performed on brucella laked blood agar with 340 isolates and 14 antimicrobial agents by the standard agar dilution technique and the spiral gradient technique in which antibiotic concentrations were established by diffusion from the agar surface. For comparison, spiral gradient MICs were determined by calculating antimicrobial concentrations at growth endpoints and rounding up to the next twofold incremental concentration. The cumulative percentage of strains susceptible at the breakpoint determined from spiral gradient data was within 10%, generally, of the percentage of strains susceptible at the breakpoint determined from agar dilution data. The overall agreement between the two techniques (within one doubling dilution) was 90.6%. The spiral gradient agar dilution technique is a reasonable alternative to the conventional agar dilution technique for susceptibility testing of anaerobic bacteria. Images PMID:1929262

  16. A new chemical approach to optimize the in vitro SPF method on the HD6 PMMA plate.

    PubMed

    Marguerie, S; Pissavini, M; Baud, A; Carayol, T; Doucet, O

    2012-01-01

    In a previous study, we demonstrated that control of the roughness of molded PMMA plates improves in vitro SPF reproducibility. However, in vitro/vivo deviations are still observed. Sunscreens show different behavior during spreading on the HD6 surface according to the formulation, resulting in a more or less homogenous distribution. The hydrophilic nature of HD6 appears to contribute significantly during spreading. Two different sunscreens offering a homogenous and non-homogenous distribution were investigated to check if the interfacial tension between product and substrate has a real influence on the spreading quality. Using microscopic observations, we attempted to correlate the in vitro SPF results with the product's spreading property. In order to reduce this interfacial tension, an HD6 pretreatment with an amphoteric surfactant, cocamidopropyl betain, was performed. In vitro SPF on "pretreated HD6" was examined using a cohort of 30 products. This pretreatment led to reliable results, demonstrating good association with the in vivo SPF.

  17. TM01-mode microwave propagation property analysis for plasmas with disk-plate windows by a finite-difference time-domain method

    SciTech Connect

    Okamura, Yoshimasa; Yamamoto, Yoshito; Fujita, Kazuhiro; Miyoshi, Taiki; Teramoto, Koji; Kawaguchi, Hideki; Kagami, Shin; Furukawa, Masakazu

    2007-07-15

    Numerical studies of microwave propagation properties in a conical horn and an adjustable waveguides, and for plasmas generated under disk-plate windows of a 220 mm diameter and in a vacuum chamber are studied by a finite-difference time-domain (FDTD) method including plasma equations. In the numerical studies, a TM01-mode microwave of 2.45 GHz at a power of 1 kW is supplied from the top of the conical horn waveguide. In addition, numerical results by the FDTD method are compared with experimental results, and a validity of the numerical results is investigated. From the numerical results, it is found that the TM01-mode microwave changes its field shape and propagates along inner surfaces of the conical horn and the adjustable waveguides. Then electromagnetic fields of the TM01-mode microwave concentrate at the center surfaces of the disk-plate windows [quartz ({epsilon}{sub r}=3.8), alumina ({epsilon}{sub r}=9.7), and WG20 ({epsilon}{sub r}=20.0)]. A diameter of higher concentration is within 80 mm, and the orientation of electric field is almost vertical to the disk-plate window. The diameters within 80 mm are equivalent to a diameter at a higher electron density in an oxygen plasma experiment in the volume mode at 1 kW and 133 Pa with a quartz window. When heights of the adjustable waveguide are changed from 64 to 244 mm, peaks of electric fields in the heights, where microwave power is estimated to be strongly absorbed into the plasmas, appear and peak positions of the electric fields are observed periodically in surface-wave mode plasmas as well as the volume mode plasmas. Heights of the peaks increase with increasing dielectric constant and peak-to-peak distances of the peak positions decrease with increasing dielectric constant. The peak positions agree to the minimum microwave power reflections tuned by a combination of an autotuning unit and adjustable waveguide heights in experiments. Furthermore, peak positions of relatively absorbed microwave powers in

  18. INL HIP Plate Fabrication

    SciTech Connect

    B. H. Park; C. R. Clark; J. F. Jue

    2010-02-01

    This document outlines the process used to bond monolithic fuel plates by Hot Isostatic Pressing (HIP). This method was developed at Idaho National Laboratory (INL) for the Reduced Enrichment for Research and Test Reactors (RERTR) program. These foils have been used in a number of irradiation experiments in support of the United States Global Threat Reduction Initiative (GTRI) program.

  19. The method used for justification of engineering solutions for multistage plate-type mufflers attached to gas-air ducts of thermal power plants

    NASA Astrophysics Data System (ADS)

    Tupov, V. B.

    2013-08-01

    This paper describes technical and economic problems associated with the selection of designs of mufflers attached to gas-air ducts of thermal power plants. A method is suggested that makes it possible to determine the dimensions of each stage of plate-type mufflers on the basis of achieving the lowest total discounted costs in order to provide the required acoustical performance at a permissible aerodynamic resistance of a muffler. The condition of the lowest total discounted costs for a multistage muffler, which is valid for different types of mufflers, has been obtained.

  20. Algivirga pacifica gen. nov., sp. nov., a novel agar-degrading marine bacterium of the family Flammeovirgaceae isolated from Micronesia.

    PubMed

    Kim, Jennifer Jooyoun; Kim, Ji Hyung; Kwon, Young-Kyung; Kwon, Kae Kyoung; Yang, Sung-Hyun; Jang, Jiyi; Heo, Soo-Jin; Park, Heung-Sik; Jung, Won-Kyo; Lee, Youngdeuk; Kang, Do-Hyung; Oh, Chulhong

    2013-12-01

    An aerobic, Gram-negative, coccoid to short rod-shaped and non-flagellated marine bacterial strain S354(T) was isolated from seawater of Micronesia. The strain was capable to degrade agar-forming slight depression into agar plate. Growth occurred at a temperature range of 12-44 °C, a pH range of 5-9, and a salinity range of 1-7 % (w/v) NaCl. Phylogenetic analyses based on 16S rRNA gene sequences suggested that S354(T) belongs to the family Flammeovirgaceae. The novel strain was most closely related to Limibacter armeniacum YM 11-185(T) with similarity of 92.5 %. The DNA G+C content was 43.8 mol%. The major fatty acids (>10 %) were iso-C15:0 and C16:1 ω5c. The predominant isoprenoid quinone was determined to be MK-7. Polar lipid profile of S354(T) consisted of phosphatidylethanolamine, unknown polar lipid, and unknown glycolipids. Based on the phenotypic, phylogenetic, biochemical, and physiological tests conducted in this study, S354(T) is proposed to represent a type strain of a novel genus and species. The 16S rRNA gene sequence of S354(T) is registered in GenBank under the accession number JQ639084. The type of strain Algivirga pacifica gen. nov., sp. nov. is S354(T) (=KCCM 90107(T)=JCM 18326(T)).

  1. Metal vapor arc ion plating

    DOEpatents

    Bertram, L.A.; Fisher, R.W.; Mattox, D.M.; Zanner, F.J.

    1986-09-09

    A method and apparatus for ion plating are described. The apparatus uses more negative than a first electrode voltage in a vacuum arc remelt system to attract low energy ions from the anode electrode to the article to be plated. 2 figs.

  2. Micro-channel plate detector

    DOEpatents

    Elam, Jeffrey W.; Lee, Seon W.; Wang, Hsien -Hau; Pellin, Michael J.; Byrum, Karen; Frisch, Henry J.

    2015-09-22

    A method and system for providing a micro-channel plate detector. An anodized aluminum oxide membrane is provided and includes a plurality of nanopores which have an Al coating and a thin layer of an emissive oxide material responsive to incident radiation, thereby providing a plurality of radiation sensitive channels for the micro-channel plate detector.

  3. Application of in vitro soft agar techniques for growth of tumor cells to the study of colon cancer.

    PubMed

    Buick, R N; Fry, S E; Salmon, S E

    1980-03-15

    An in vitro assay to measure the clonogenic or colony-forming capability of cancer cells present in biopsy samples has recently been applied to study the biology and drug-sensitivity of a variety of human neoplasms. This approach appears to be suitable for study of the tumor stem or progenitor cells present in malignant effusions from patients with colonic carcinoma. In our preliminary studies, morphology of the tumor colonies by inverted microscopy and with Papanicolaou staining of dried agar plating layers as well as immunofluorescent localization with a specific antiserum to human carcinoembrionic antigen have been used as markers of the neoplastic origin of colon tumor colony-forming cells. Successful application of this assay to colonic solid tumors will require improvement in techniques for disaggregation of viable clonogenic cells. We anticipate that short term clonal assays will have increasing use for clinical and biological studies of human colon cancer.

  4. Effect of seaweed on mechanical, thermal, and biodegradation properties of thermoplastic sugar palm starch/agar composites.

    PubMed

    Jumaidin, Ridhwan; Sapuan, Salit M; Jawaid, Mohammad; Ishak, Mohamad R; Sahari, Japar

    2017-06-01

    The aim of this paper is to investigate the characteristics of thermoplastic sugar palm starch/agar (TPSA) blend containing Eucheuma cottonii seaweed waste as biofiller. The composites were prepared by melt-mixing and hot pressing at 140°C for 10min. The TPSA/seaweed composites were characterized for their mechanical, thermal and biodegradation properties. Incorporation of seaweed from 0 to 40wt.% has significantly improved the tensile, flexural, and impact properties of the TPSA/seaweed composites. Scanning electron micrograph of the tensile fracture showed homogeneous surface with formation of cleavage plane. It is also evident from TGA results that thermal stability of the composites were enhanced with addition of seaweed. After soil burial for 2 and 4 weeks, the biodegradation of the composites was enhanced with addition of seaweed. Overall, the incorporation of seaweed into TPSA enhances the properties of TPSA for short-life product application such as tray, plate, etc.

  5. Improved method for detection of starch hydrolysis

    SciTech Connect

    Ohawale, M.R.; Wilson, J.J.; Khachatourians, G.G.; Ingledew, W.M.

    1982-09-01

    A new starch hydrolysis detection method which does not rely on iodine staining or the use of color-complexed starch is described. A linear relationship was obtained with agar-starch plates when net clearing zones around colonies of yeasts were plotted against enzyme levels (semilogarithm scale) produced by the same yeast strains in liquid medium. A similar relationship between starch clearing zones and alpha-amylase levels from three different sources was observed. These observations suggest that the method is useful in mutant isolations, strain improvement programs, and the prediction of alpha-amylase activities in culture filtrates or column effluents. (Refs. 18).

  6. Comparison of isolation of Haemophilus vaginalis (Corynebacterium vaginale) from peptone-starch-dextrose agar and Columbia colistin-nalidoxic acid agar.

    PubMed Central

    Golberg, R L; Washington JA, I I

    1976-01-01

    A total of 447 cervical or vaginal specimens were inoculated in parallel onto peptone-starch-dextrose (PSD) and Columbia colistin (10 mg/ml)-nalidixic acid (15 mug/ml) (CNA) agar and were incubated for 48 h at 35 degrees C in an atmosphere with 2 to 10% CO2. One hundred (22.4%) of the cultures were positive for Haemophilus vaginalis. Forty-eight of the isolates were recovered from both PSD and Columbia CNA agar, five from PSD only, and 47 from Columbia CNA agar only (P less than 0.001). On Columbia CNA agar, 76 of the isolates were detected after 24 h of incubation, and the remainder were detected within 4 days of incubation. PMID:1085777

  7. Time Dependent Antinociceptive Effects of Morphine and Tramadol in the Hot Plate Test: Using Different Methods of Drug Administration in Female Rats

    PubMed Central

    Gholami, Morteza; Saboory, Ehsan; Mehraban, Sogol; Niakani, Afsaneh; Banihabib, Nafiseh; Azad, Mohamad-Reza; Fereidoni, Javid

    2015-01-01

    Morphine and tramadol which have analgesic effects can be administered acutely or chronically. This study tried to investigate the effect of these drugs at various times by using different methods of administration (intraperitoneal, oral, acute and chronic). Sixty adult female rats were divided into six groups. They received saline, morphine or tramadol (20 to 125 mg/Kg) daily for 15 days. A hot plate test was performed for the rats at the 1st, 8th and 15th days. After drug withdrawal, the hot plate test was repeated at the 17th, 19th, and 22nd days. There was a significant correlation between the day, drug, group, and their interaction (P<0.001). At 1st day (d1), both morphine, and tramadol caused an increase in the hot plate time comparing to the saline groups (P<0.001), while there was no correlation between drug administration methods of morphine and/or tramadol. At the 8th day (d8), morphine and tramadol led to the most powerful analgesic effect comparing to the other experimental days (P<0.001). At the 15th day (d15), their effects diminished comparing to the d8. After drug withdrawal, analgesic effect of morphine, and tramadol disappeared. It can be concluded that the analgesic effect of morphine and tramadol increases with the repeated use of them. Thereafter, it may gradually decrease and reach to a level compatible to d1. The present data also indicated that although the analgesic effect of morphine and tramadol is dose-and-time dependent, but chronic exposure to them may not lead to altered nociceptive responses later in life. PMID:25561936

  8. Electrochemical Assay of Gold-Plating Solutions

    NASA Technical Reports Server (NTRS)

    Chiodo, R.

    1982-01-01

    Gold content of plating solution is assayed by simple method that required only ordinary electrochemical laboratory equipment and materials. Technique involves electrodeposition of gold from solution onto electrode, the weight gain of which is measured. Suitable fast assay methods are economically and practically necessary in electronics and decorative-plating industries. If gold content in plating bath is too low, poor plating may result, with consequent economic loss to user.

  9. A direct LC/MS/MS method for the determination of ciclopirox penetration across human nail plate in in vitro penetration studies.

    PubMed

    Bu, Wei; Fan, Xiaoqing; Sexton, Holly; Heyman, Irwin

    2010-01-05

    Due to severe chelating effect caused by N-hydroxylpyridone group of ciclopirox, there is no published direct HPLC or LC/MS/MS method for the determination of ciclopirox in any in vitro or in vivo matrix. Instead, the time-consuming pre-column derivatization methods have been adapted for indirect analysis of ciclopirox. After overcoming the chelating problem by using K(2)EDTA coated tubes, a direct, sensitive and high-throughput LC/MS/MS method was successfully developed and validated to determine the amount of ciclopirox that penetrated across the nail plate during in vitro nail penetration studies. The method involved adding a chemical analog, chloridazon as internal standard (IS) in K(2)EDTA coated tubes, mixing IS with ciclopirox in a 96-well plate and then proceeding to LC/MS/MS analysis. The MS/MS was selected to monitor m/z 208.0-->135.8 and 221.8-->77.0 for ciclopirox and IS, respectively, using positive electrospray ionization. The method was validated over a concentration range of 8-256 ng/mL, yielding calibration curves with correlation coefficients greater than 0.9991 with a lower limit of quantitation (LLOQ) of 8 ng/mL. The assay precision and accuracy were evaluated using quality control (QC) samples at three concentration levels. Analyzed concentrations ranged from 101% to 113% of their respective nominal concentration levels with coefficients of variation (CV) below 10.6%. The average recovery of ciclopirox from nail matrix was 101%. The validated method was successfully used to analyze the ciclopirox formulation and in vitro nail penetration samples.

  10. EXPERIMENTAL STUDY ON CLASSIFICATION OF LAYOUT METHODS OF A STEEL PLATE AND EFFECT OF DECREASE IN ACTING PRESSURE ON BEARING GROUND THROUGH THE CRAWLERS OF DRILL RIGS.

    NASA Astrophysics Data System (ADS)

    Hori, Tomohito; Tamate, Satoshi; Kikkawa, Naotaka; Itoh, Kazuya

    Drill rigs are large pieces of construction machinery, used to build pile foundations and improve ground stability. In recent years, there have been several reports of accidents where drill rigs have toppled over. Two potential causes for these accidents are related to drill rigs becoming unstable. One cause is structural instability, where the body is composed of a top heavy weight distribution. The other is concerned with the supporting ground. During the construction process, rig sites are excavated and overlaid by reclaimed soil. These works produce uneven surfaces, as well as a distribution of different stiffnesses in the supporting ground. In this study, we first classify layout methods of a steel plate and conduct loading tests with several layout patterns while decreasing the acting pressure on the bearing ground through the crawlers. Secondly, a series of experimental simulations using a 1/25 scale model of a drill rig are performed in a centrifuge, in order to investigate the cause of drill rig instability with motion-image sequence analysis. Finally, we discuss the optimum layout methods of the steel plate.

  11. Antibiotic susceptibility of Stenotrophomonas (Xanthomonas) maltophilia: comparative (NCCLS criteria) evaluation of antimicrobial drugs with the agar dilution and the agar disk diffusion (Bauer-Kirby) tests.

    PubMed

    Traub, W H; Leonhard, B; Bauer, D

    1998-01-01

    Ninety-six clinical isolates of Stenotrophomonas maltophilia were examined with the agar dilution method for susceptibility to 19 antimicrobial drugs. Doxycycline, cotrimoxazole, timentin, ofloxacin, fosfomycin, and piperacillin + tazobactam, in that order, inhibited the majority of strains. All isolates were resistant to nitrofurantoin. Concurrent disk susceptibility (Bauer-Kirby method) testing, using currently valid NCCLS interpretative criteria for Pseudomonas aeruginosa, uncovered a significant incidence of very major (category I), major (category II), and minor (categories III and IV) discrepancies for aminoglycosides, cephalosporins, chloramphenicol, and piperacillin + tazobactam and ticarcillin + clavulanic acid. Therefore, new interpretative criteria indicative of intermediate (I) susceptibility of S. maltophilia to these various antibiotics were proposed. In addition, new intermediate susceptibility criteria were proposed for the two beta-lactam-beta-lactamase inhibitor combinations. It was recommended to exclude ciprofloxacin from test batteries against this microorganism due to the wide scatter of minimal inhibitory concentration values and diameters of inhibition zones; the same was true for polymyxin B. It is hoped that the proposed modified, species-specific criteria will improve the clinical utility of laboratory-generated disk antibiograms with respect to the inherently multiple antibiotic-resistant, opportunistic pathogen S. maltophilia.

  12. Detection of mycobacteria by radiometric and standard plate procedures.

    PubMed Central

    Damato, J J; Collins, M T; Rothlauf, M V; McClatchy, J K

    1983-01-01

    A group of 89 smear-positive sputum specimens were evaluated by radiometric and standard plate procedures to determine the methodology which would provide the earliest detection of mycobacteria and maximum test sensitivity. Digested non-decontaminated specimens were concentrated and inoculated into modified selective BACTEC radiometric 7H12 broth and Mitchison selective 7H10 agar. Sodium hydroxide (1.5% final concentration) was then used to decontaminate these specimens. They were then concentrated and inoculated into both selective and nonselective 7H12 radiometric broths and into selective 7H10 and nonselective Middlebrook 7H11 agar media. The specimen processing and media combinations providing the earliest detection were non-decontaminated specimens with modified selective 7H12 BACTEC broth and decontaminated specimens with 7H12 BACTEC broths. Maximum sensitivity (percent positive) was obtained by using non-decontaminated specimens on Mitchison selective 7H10 Agar (98%) or decontaminated specimens in 7H12 BACTEC broth (95%). The decontamination process was found to reduce significantly the number of mycobacteria in clinical specimens, particularly the mycobacteria other than Mycobacterium tuberculosis. The specimen processing-media combinations providing the earliest detection and maximum recovery of mycobacteria (100%) were non-decontaminated specimens with modified selective 7H12 BACTEC broth or Mitchison selective agar and decontaminated specimens with 7H12 BACTEC broth or 7H11 agar. PMID:6348076

  13. Visualization of Thermal Distribution Caused by Focused Ultrasound Field in an Agar Phantom

    NASA Astrophysics Data System (ADS)

    Kim, Jungsoon; Kim, Moojoon; Ha, Kanglyeol

    2011-07-01

    Ultrasound waves have been widely used not only in medical diagnostic systems but also in medical treatment. There has been increasing interest in the thermal distribution caused by ultrasound waves. In this study, using thermochromic particles, a visualization method was suggested in a mimic phantom for organic materials. By blending various thermochromic particles with different critical temperatures, the thermal field distribution in the phantom could be observed. The effect of a concave-type ultrasound transducer on the temperature distribution in an agar phantom mixed with thermochromic particles was observed. The temperature distribution corresponded to changes in the brightness distribution of gray. It was confirmed that the thermal distribution pattern in the vicinity of the focal area varies with the time exposure to ultrasound waves.

  14. New Approaches on Quantification of Campylobacter jejuni in Poultry Samples: The Use of Digital PCR and Real-time PCR against the ISO Standard Plate Count Method

    PubMed Central

    Papić, Bojan; Pate, Mateja; Henigman, Urška; Zajc, Urška; Gruntar, Igor; Biasizzo, Majda; Ocepek, Matjaž; Kušar, Darja

    2017-01-01

    Campylobacteriosis is the most frequently reported bacterial food-borne illness in the European Union and contaminated broiler meat is considered the most important source of infection in humans. The aim of the present study was to evaluate real-time PCR (qPCR) and digital PCR (dPCR) for quantification of Campylobacter jejuni in 75 broiler neck-skin samples collected from a poultry slaughterhouse, and to compare them with the ISO 10272-2 standard plate count method. For qPCR standard curve, C. jejuni-negative neck-skin samples were spiked with C. jejuni suspension with a known number of bacterial cells. The observed CFU/g values by qPCR correlated greatly with the expected values and qPCR showed good performance with the reliable limit of detection (rLOD) and limit of quantification (LOQ) of three and 31 target copies per reaction, respectively. However, both rLOD (1219 CFU/g) and LOQ (12,523 CFU/g) were beyond the EFSA-proposed critical limit of 500–1,000 CFU/g of neck skin. Although C. jejuni cell counts were ≤1,000 CFU/g in only 7/75 samples by plate counting, they were ≤LOQ in 60/75 and ≤rLOD in 26/75 (≤1,000 CFU/g in 24/75) samples by qPCR. A strong and statistically significant correlation was observed between qPCR and dPCR. Both PCR-based methods correlated significantly with the plate count method; however, the correlation was moderate. Using the Bland–Altman analysis, an average agreement was noted between all three methods, although with a large standard deviation. A significant bias toward overestimation in dPCR was observed, probably due to the relatively high number of false positive calls. The linear dynamic range was comparable in both PCR-based methods; however, qPCR proved to be more suitable for routine use. In the future, the establishment of a reliable molecular quantification of C. jejuni in poultry samples showing a wide range of contamination levels down to the proposed critical limit is needed to enable time- and cost

  15. Evaluation of fluorogenic TSC agar for recovering Clostridium perfringens in groundwater samples.

    PubMed

    Araujo, M; Sueiro, R A; Gómez, M J; Garrido, M J

    2001-01-01

    Clostridium perfringens is widely recognised as a reliable water pollution indicator. Since several media can be employed for the membrane filtration enumeration of this microorganism, the main aim of this work was to investigate the ability of fluorocult-supplemented TSC-agar (Merck) for recovering Cl. perfringens from public springs used for direct human consumption. Cl. perfringens recovery was also performed on mCP agar (Cultimed) according to Directive 98/83 as well as on TSC-Agar (Merck), TSN-Agar (Merck) and SPS-Agar (BBL) media. Variance analysis of data obtained showed no statistically significant differences in the counts obtained among all media employed in this work. However, the Cl. perfringens recovery efficiencies with TSC and fluorogenic TSC agars were significantly greater (P = < 0.05) than the corresponding values of mCP and TSN media. On the other hand, the identification of typical and atypical colonies isolated from all media demonstrated that fluorogenic TSC agar was the most specific medium for Cl. perfringens recovery in groundwater samples (85.3% of typical colonies and 82.8% of atypical colonies confirmed). In summary, the membrane filtration technique with fluorogenic TSC agar showed the best performance characteristics of all the media tested as judged by their recovery efficiency and specificity in these water samples.

  16. Electrospinning of agar/PVA aqueous solutions and its relation with rheological properties.

    PubMed

    Sousa, Ana M M; Souza, Hiléia K S; Uknalis, Joseph; Liu, Shih-Chuan; Gonçalves, Maria P; Liu, LinShu

    2015-01-22

    In this work, we report the successful fabrication of agar-based nanofibers by electrospinning technique, using water as solvent media. A tubeless spinneret was attached inside the electrospinning chamber, operating at 50°C, to avoid agar gelation. Agar pure solution (1 wt%) showed inadequate spinnability regardless of the used electrospinning conditions. The addition of a co-blending polymer such as PVA (10 wt% starting solution) improved the solutions viscoelasticity and hence, the solutions spinnability. Agar/PVA solutions were prepared with different mass ratios (100/0, 50/50, 40/60, 30/70, 20/80 and 0/100) and electrospun at various sets of electrospinning conditions. Best nanofibers were obtained with 30/70 and 20/80 agar/PVA blends while samples with higher agar contents (50/50 and 40/60 agar/PVA) were harder to process and led to discontinuous fibrous mats. This first set of encouraging results can open a new window of opportunities for agar-based biomaterials in the form of nanofibers.

  17. Characteristics of thermoplastic sugar palm Starch/Agar blend: Thermal, tensile, and physical properties.

    PubMed

    Jumaidin, R; Sapuan, S M; Jawaid, M; Ishak, M R; Sahari, J

    2016-08-01

    The aim of this work is to study the behavior of biodegradable sugar palm starch (SPS) based thermoplastic containing agar in the range of 10-40wt%. The thermoplastics were melt-mixed and then hot pressed at 140°C for 10min. SEM investigation showed good miscibility between SPS and agar. FT-IR analysis confirmed that SPS and agar were compatible and inter-molecular hydrogen bonds existed between them. Incorporation of agar increased the thermoplastic starch tensile properties (Young's modulus and tensile strength). The thermal stability and moisture uptake increased with increasing agar content. The present work shows that starch-based thermoplastics with 30wt% agar content have the highest tensile strength. Higher content of agar (40wt%) resulted to more rough cleavage fracture and slight decrease in the tensile strength. In conclusion, the addition of agar improved the thermal and tensile properties of thermoplastic SPS which widened the potential application of this eco-friendly material. The most promising applications for this eco-friendly material are short-life products such as packaging, container, tray, etc.

  18. Plating Processes Utilizing High Intensity Acoustic Beams

    NASA Technical Reports Server (NTRS)

    Oeftering, Richard C. (Inventor); Denofrio, Charles (Inventor)

    2002-01-01

    A system and a method for selective plating processes are disclosed which use directed beams of high intensity acoustic waves to create non-linear effects that alter and improve the plating process. The directed beams are focused on the surface of an object, which in one embodiment is immersed in a plating solution, and in another embodiment is suspended above a plating solution. The plating processes provide precise control of the thickness of the layers of the plating, while at the same time, in at least some incidents, eliminates the need for masking.

  19. Adsorptive removal of methylene blue by agar: effects of NaCl and ethanol

    PubMed Central

    2012-01-01

    Adsorption of methylene blue (MB) on agar was investigated as a function of temperature (308-328 K), different concentrations of NaCl and HCl and various weight percentages of binary mixtures of ethanol with water. It was observed that the maximum experimental adsorption capacity, qm, exp, in water is up to 50 mg g-1 and decreases with increase in weight percentage of ethanol and NaCl and HCl concentration compared to that of water. Analysis of data using ARIAN model showed that MB adsorbs as monomer and dimer on the surface of agar. Binding constants of MB to agar were calculated using the Temkin isotherm. The process is exothermic in water and other solutions. The mean adsorption energy (E) value indicated binding of MB to agar is chemical adsorption. Kinetics of this interaction obeys from the pseudo-second-order model and diffusion of the MB molecules into the agar is the main rate-controlling step. PMID:22339759

  20. Morphometric and colorimetric analyses of human tumor cell line growth and drug sensitivity in soft agar culture.

    PubMed

    Alley, M C; Pacula-Cox, C M; Hursey, M L; Rubinstein, L R; Boyd, M R

    1991-02-15

    Previous studies have demonstrated the suitability of image analysis of tetrazolium-stained colonies to assess growth and drug sensitivity of human tumor cells cultivated in soft agar culture. In the present study, the potential utility of colorimetric analysis to expedite experimental drug evaluations using human tumor cell lines was investigated. The same culture dishes were assessed by image analysis and by formazan colorimetry for purposes of comparing multiple methods of measuring growth as well as growth inhibition. Replicate cultures treated with 2-(p-iodonitrophenyl)-3-p-nitrophenyl-5-phenyltetrazolium chloride or 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide exhibited nearly identical colony count and volume indices as well as excellent correlation in colorimetric end points. Colony-forming unit volume analysis versus colorimetric assessment of the same cultures following dimethyl sulfoxide extraction of protamine sulfate-rinsed, dried soft agar cultures exhibited excellent linear correlation for both growth (Pearson r ranging from 0.95 to 1.00) and drug sensitivity (Pearson r ranging from 0.90 to 0.99, and Spearman r ranging from 0.82 to 0.97) and similar drug sensitivity profiles. Results of the current investigation indicate that end points of soft agar culture remain stable for a period of at least 2 weeks following assay termination. In addition, a colorimetric detection range of 1.3-2.2 log units permits determinations of survival levels ranging from 100 to 5% of respective control levels. Colorimetric analysis is anticipated to expedite soft agar colony formation assay evaluations (a) by reducing the need to use the more rigorous and time-consuming image analysis procedures to measure activity in preliminary drug sensitivity assays and (b) by permitting the determination of effective concentration ranges of new experimental agents for subsequent, more detailed investigations.

  1. Performance of Chromogenic Candida agar and CHROMagar Candida in recovery and presumptive identification of monofungal and polyfungal vaginal isolates.

    PubMed

    Ozcan, Kadri; Ilkit, Macit; Ates, Aylin; Turac-Bicer, Aygul; Demirhindi, Hakan

    2010-02-01

    Chromogenic Candida agar (OCCA) is a novel medium facilitating isolation and identification of Candida albicans, C. tropicalis, and C. krusei, as well as indicating polyfungal population in clinical samples. We compare the performance of OCCA, to CHROMagar Candida (CAC) and Sabouraud chloramphenicol agar (SCA). Vaginal swab samples from 392 women were simultaneously inoculated onto three study media. A total of 161 (41.1%) were found to be positive for fungi of which 140 (87%) were monofungal, and 21 (13%) polyfungal. One-hundred and fifty-seven samples (97.5%) were positive on CAC, 156 (96.9%) on OCCA, 148 (91.9%) on SCA and 144 (89.4%) samples were positive on all three media. The yeasts were identified by conventional methods including germ tube test, microscopic morphology on cornmeal-Tween 80 agar, and the commercial API 20C AUX. The 182 isolates were C. albicans (n = 104), C. glabrata (n = 51), C. krusei (n = 7), C. tropicalis (n = 5), C. famata (n = 3), C. kefyr (n = 3), C. zeylanoides (n = 3), C. colliculosa (n = 2), and other species of Candida (n = 4). Among the 21 polyfungal populations, 20 (95.2%) were detected in OCCA, 14 (66.7%) in CAC, and 13 (61.9%) in CAC and OCCA (P <0.05). Most polyfungal populations (47.6%) yielded C. albicans + C. glabrata. The efficiency of both chromogenic media for C. albicans was >or=92.9% at 72 h. OCCA is more efficient and reliable for rapidly identifying C. albicans and polyfungal populations than CAC. However, CAC is more efficient for identifying C. krusei and C. tropicalis. A chromogenic agar with a higher isolation rate of yeasts and better detection of polyfungal populations than SCA, is suggested as a medium of first choice when available.

  2. Comparison of the BBL CHROMagar Staph aureus Agar Medium to Conventional Media for Detection of Staphylococcus aureus in Respiratory Samples

    PubMed Central

    Flayhart, Diane; Lema, Clara; Borek, Anita; Carroll, Karen C.

    2004-01-01

    Screening for Staphylococcus aureus has become routine in certain patient populations. This study is the first clinical evaluation of the BBL CHROMagar Staph aureus agar (CSA) medium (BD Diagnostics, Sparks, Md.) for detection of S. aureus in nasal surveillance cultures and in respiratory samples from cystic fibrosis (CF) patients. S. aureus colonies appear mauve on CSA. Other organisms are inhibited or produce a distinctly different colony color. S. aureus was identified from all media by slide coagulase, exogenous DNase, and mannitol fermentation assays. Susceptibility testing was performed using the agar dilution method. A total of 679 samples were evaluated. All samples were inoculated onto CSA. Nasal surveillance cultures were inoculated onto sheep blood agar (SBA) (BD Diagnostics), and samples from CF patients were inoculated onto mannitol salt agar (MSA) (BD Diagnostics). Of the 679 samples cultured, 200 organisms produced a mauve color on CSA (suspicious for S. aureus) and 180 were positive for S. aureus on SBA or MSA. Of 200 CSA-positive samples 191 were identified as S. aureus. Nine mauve colonies were slide coagulase negative and were subsequently identified as Staphylococcus lugdunensis (one), Staphylococcus epidermidis (three), Staphylococcus haemolyticus (one), and Corynebacterium species (four). CSA improved the ability to detect S. aureus by recovering 12 S. aureus isolates missed by conventional media. Of the 192 S. aureus isolates recovered, 122 were methicillin susceptible and 70 were methicillin resistant. Overall, the sensitivity and specificity of CSA in this study were 99.5 and 98%, respectively. There was no difference in the performance of the slide coagulase test or in susceptibility testing performed on S. aureus recovered from CSA compared to SBA or MSA. Our data support the use of CSA in place of standard culture media for detection of S. aureus in heavily contaminated respiratory samples. PMID:15297498

  3. Measurement of human tumour cell growth in soft-agar cultures using computer-assisted volume analysis.

    PubMed Central

    Alley, M. C.; Lieber, M. M.

    1985-01-01

    Growth in soft-agar bilayer cultures of human tumour cells derived from 4 in vitro continuous cell lines, from 21 xenografts carried in athymic mice, and from 197 samples of fresh human solid tumours of various histologic types was analyzed by computer-assisted image analysis. Replicate cultures for each specimen were assessed on successive days of incubation for the number and volume of growth units within multiple size categories. Our results confirm the recent finding of others that there is an upper limit of approximately 10(9) microns 3 to the cumulative growth unit volume obtainable in a 2 ml bilayer soft agar culture system. Since this upper limit to the carrying capacity of the closed culture system exists, the extent of growth within the cultures is determined in a fundamental way by the cumulative volume of growth units initially inoculated into cultures. A growth index of greater than or equal to 16-fold was only seen when initial cumulative growth unit volume was less than 10(7) microns 3 per culture dish. Computer-assisted volume analysis (CAVA) appears to be a useful quantitative method to study the growth of human tumour cells in soft agar cultures. PMID:4027164

  4. An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MS/MS.

    PubMed

    Wang, Wan; Qin, Suzi; Li, Linsen; Chen, Xiaohua; Wang, Qunjie; Wei, Junfu

    2015-01-01

    A high throughput sample preparation method was developed utilizing mixed-mode solid phase extraction (SPE) in 96-well plate format for the determination of free arachidonic acid in plasma by LC-MS/MS. Plasma was mixed with 3% aqueous ammonia and loaded into each well of 96-well plate. After washing with water and methanol sequentially, 3% of formic acid in acetonitrile was used to elute arachidonic acid. The collected fraction was injected onto a reversed phase column at 30°C with mobile phase of acetonitrile/water (70 : 30, v/v) and detected by LC-MS/MS coupled with electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. The calibration curve ranged from 10 to 2500 ng/mL with sufficient linearity (r (2) = 0.9999). The recoveries were in the range of 99.38% to 103.21% with RSD less than 6%. The limit of detection is 3 ng/mL.

  5. Chances and limits of an improved method to assess water resistance of cosmetic sunscreen products in vitro on polymethylmethacrylate plates.

    PubMed

    Bielfeldt, S; Röck, C; Wilhelm, K-P

    2013-02-01

    While sun protection factor (SPF) and UVA protection are the most important determinants of a cosmetic sunscreen product, water resistance is the third important feature. The Colipa in vivo method is the internationally accepted standard method to assess water resistance. It is time-consuming and expensive. A screening method to quickly predict water resistance properties on low cost therefore is a specific request of product developers. Several in vitro screening methods are published but the predictive power of all these methods is limited. In this paper, we describe an adaptation of the in vitro UVA protection method of Colipa for a water resistance screening. Although the method is quick and most parts are standardized and approved by Colipa, the results were not in advantage of other published screening methods. Taking into account, the scatter of the results, seven of 16 sunscreen products that were developed as water resistant formulations could be unambiguously estimated to be water resistant by the in vivo water resistance screening method on five subjects while nine failed. In 10 of these 16 results, the in vitro SPF-based method was in accordance with in vivo findings, whereas in six cases, the method was not predicting correctly. Based on these results, the authors recommend to use the in vitro screening methods to pre-select from candidates which cannot all be tested in vivo. The pre-selected products can be screened in the Colipa in vivo water resistance method with a reduced number of volunteers (usually 5) to predict water resistance. In case, the water resistance estimated in such an in vivo screening is found at about 65% or higher the study can be deemed successful and completed with further subjects to fulfil the Colipa requirements.

  6. Electrically induced mechanical precompression of ferroelectric plates

    DOEpatents

    Chen, P.J.

    1987-03-02

    A method of electrically inducing mechanical precompression of ferroelectric plate covered with electrodes utilizes the change in strains of the plate as functions of applied electric field. A first field polarizes and laterally shrinks the entire plate. An outer portion of the electrodes are removed, and an opposite field partially depolarizes and expands the central portion of the plate against the shrunk outer portion. 2 figs.

  7. Electrically induced mechanical precompression of ferroelectric plates

    DOEpatents

    Chen, Peter J.

    1987-01-01

    A method of electrically inducing mechanical precompression of a ferroelectric plate covered with electrodes utilizes the change in strains of the plate as functions of applied electric field. A first field polarizes and laterally shrinks the entire plate. An outer portion of the electrodes are removed, and an opposite field partially depolarizes and expands the central portion of the plate against the shrunk outer portion.

  8. Underwater electrical discharge in plate to plate configuration

    NASA Astrophysics Data System (ADS)

    Stelmashuk, Vitaliy

    2016-09-01

    Two main configurations of high voltage electrodes submersed in water have been used for an electrical discharge generation: pin to pin and pin to plate. An electrical breakdown between plate electrodes is generally difficult to reproduce, because there is a uniform and weak electric field. One major advantage of using plate electrodes is their greater ``wear hardness'' to high-energy discharges. The plate electrodes can withstand extremely high energy deposition at which the pin electrode is quickly destroyed. The electrical discharge between plate electrodes can be initiated by creating an inhomogeneity in the electrical field. Two methods of discharge initiation between plate electrodes are proposed for this aim: 1) focusing of a shock wave in the interelectrode region; 2) a bubble injection into the electrode gap. The shock wave creates favourable conditions for the electrical breakdown between the two plate electrodes: it causes that numerous microbubbles of dissolved air start to grow and serve as locations for streamer initiation. In the second method the gas bubble is injected from the one of the electrodes, which has a gas inlet hole on the lateral face for this purpose. A ``volcano'' like morphology of positive streamers are observed in the experiments with weak electric field. The authors are grateful to MEYS grant INGO LG 15013.

  9. COMPARISON OF DIRECT PLATING MEDIA FOR THE ISOLATION AND ENUMERATION OF ENTEROCOCCI IN CERTAIN FROZEN FOODS.

    PubMed

    BURKWALL, M K; HARTMAN, P A

    1964-01-01

    A total of 15 agar media were examined for their yield, selectivity, readability, and simplicity of preparation and use. A thallium medium of Barnes was selected as the better of the high yield-fair selectivity type of medium and an azide-citrate medium of Reinbold appeared to be the better of the low yield-high selectivity type of medium. Sodium carbonate (optimal concentration, 0.20%) was found to increase recovery substantially when added to certain media, especially in the presence of 0.05% Tween 80. When these two ingredients were incorporated into a medium modified after Slanetz and Bartley, the resultant medium was superior to other media for the isolation and enumeration of enterococci in certain frozen foods, such as peas and hamburger, by the direct plating method.

  10. Corrugated cover plate for flat plate collector

    DOEpatents

    Hollands, K. G. Terry; Sibbitt, Bruce

    1978-01-01

    A flat plate radiant energy collector is providing having a transparent cover. The cover has a V-corrugated shape which reduces the amount of energy reflected by the cover away from the flat plate absorber of the collector.

  11. Universal growth of microdomains and gelation transition in agar hydrogels.

    PubMed

    Boral, Shilpi; Saxena, Anita; Bohidar, H B

    2008-03-27

    Investigations were carried out on aqueous sols and gels of agar (extracted from red seaweed Gelidiella acerosa) to explore the growth of microdomains en route to gelation. Isothermal frequency sweep studies on gel samples revealed master plots showing power-law dependence of gel elastic modulus, |G*|, on oscillation frequency, omega as |G*| approximately omegan, independent of temperature, with 0.5Tg). The S(q,t) behavior close to the gel transition point (Tg approximately (38+/-3 degrees C determined from rheology) followed a stretched exponential function: S(t)=A exp(-t/ts)beta. The beta factor increased from 0.25 to 1 as the gel temperature approached 25 degrees C from Tg, and relaxation time, ts, showed a peak at T approximately 30 degrees C. The SLS data (in the sol state) suggested the scaling of scattered intensity, Is(q) approximately epsilon(-gamma) (epsilon=(T/Tg-1), T>Tg) with gamma=0.13+/-0.03, and the presence of two distinct domains characterized by a Guinier regime (low q) and a power-law regime (high q). Close to and above Tg (+2 degrees C), IS(q) scaled with q as Is(q) approximately q(-alpha) with alpha=2.2+/-0.2, which decreased to 1.4+/-1 just below Tg (-2 degrees C), implying a coil-helix transition for 0.2% (w/v) and 0.3% (w/v) samples. For a 0.01% sample, alpha=3.5+/-0.5 which

  12. Elastic plate spallation

    NASA Technical Reports Server (NTRS)

    Oline, L.; Medaglia, J.

    1972-01-01

    The dynamic finite element method was used to investigate elastic stress waves in a plate. Strain displacement and stress strain relations are discussed along with the stiffness and mass matrix. The results of studying point load, and distributed load over small, intermediate, and large radii are reported. The derivation of finite element matrices, and the derivation of lumped and consistent matrices for one dimensional problems with Laplace transfer solutions are included. The computer program JMMSPALL is also included.

  13. Growth Plate Fractures

    MedlinePlus

    .org Growth Plate Fractures Page ( 1 ) The bones of children and adults share many of the same risks for injury. But because they ... to a unique injury called a growth plate fracture. Growth plates are areas of cartilage located near ...

  14. Resazurin Microtiter Assay Plate Testing of Mycobacterium tuberculosis Susceptibilities to Second-Line Drugs: Rapid, Simple, and Inexpensive Method

    PubMed Central

    Martin, Anandi; Camacho, Mirtha; Portaels, Françoise; Palomino, Juan Carlos

    2003-01-01

    The emergence of multidrug-resistant tuberculosis calls for new, rapid drug susceptibility tests. We have tested 150 Mycobacterium tuberculosis isolates against the second-line drugs ethionamide, kanamycin, capreomycin, ofloxacin, and para-aminosalicylic acid by the colorimetric resazurin microtiter assay and the proportion method. By visual reading, MICs were obtained after 8 days. A very good correlation between results by the colorimetric resazurin microtiter assay and the proportion method was obtained. The colorimetric resazurin microtiter assay is inexpensive, rapid, and simple to perform, and implementation of the assay is feasible for low-resource countries. PMID:14576129

  15. Application of the finite-difference time-domain method to scattering and radiation problems involving wires and plates

    NASA Astrophysics Data System (ADS)

    Beker, B.

    1992-12-01

    Numerical modeling of electromagnetic (EM) interaction is normally performed by using either differential or integral equation methods. Both techniques can be implemented to solve problems in frequency or time domain. The method of moments (MOM) approach to solving integral equations has matured to the point where it can be used to solve complex problems. In the past, MOM has only been applied to scattering and radiation problems involving perfectly conducting or isotropic penetrable, lossy or lossless objects. However, many materials, (e.g., composites that are used on the Navy's surface ships in practical applications) exhibit anisotropic properties. To account for these new effects, several integral equation formulations for scattering and radiation by anisotropic objects have been developed recently. The differential equation approach to EM interaction studies has seen the emergence of the finite-difference time-domain (FD-TD) method as the method of choice in many of today's scattering and radiation applications. This approach has been applied to study transient as well as steady-state scattering from many complex structures, radiation from wire antennas, and coupling into wires through narrow apertures in conducting cavities. It is important to determine whether or not, and how effectively, the FD-TD can be used to solve EM interaction problems of interest to the Navy, such as investigating potential EM interference in shipboard communication systems. Consequently, this report partly addresses this issue by dealing exclusively with FD-TD modeling of time-domain EM scattering and radiation.

  16. Growth characteristics of Bacillus anthracis compared to other Bacillus spp. on the selective nutrient media Anthrax Blood Agar and Cereus Ident Agar.

    PubMed

    Tomaso, Herbert; Bartling, Carsten; Al Dahouk, Sascha; Hagen, Ralf M; Scholz, Holger C; Beyer, Wolfgang; Neubauer, Heinrich

    2006-01-01

    Anthrax Blood Agar (ABA) and Cereus Ident Agar (CEI) were evaluated as selective growth media for the isolation of Bacillus anthracis using 92 B. anthracis and 132 other Bacillus strains from 30 species. The positive predictive values for the identification of B. anthracis on ABA, CEI, and the combination of both were 72%, 71%, and 90%, respectively. Thus, less than 10% of all species were misidentified using both nutrient media. Species which might be misidentified as B. anthracis were B. cereus, B. mycoides, and B. thuringiensis. Particularly, 30% of B. weihenstephanensis strains were misidentified as B. anthracis.

  17. A Location Method Using Sensor Arrays for Continuous Gas Leakage in Integrally Stiffened Plates Based on the Acoustic Characteristics of the Stiffener

    PubMed Central

    Bian, Xu; Li, Yibo; Feng, Hao; Wang, Jiaqiang; Qi, Lei; Jin, Shijiu

    2015-01-01

    This paper proposes a continuous leakage location method based on the ultrasonic array sensor, which is specific to continuous gas leakage in a pressure container with an integral stiffener. This method collects the ultrasonic signals generated from the leakage hole through the piezoelectric ultrasonic sensor array, and analyzes the space-time correlation of every collected signal in the array. Meanwhile, it combines with the method of frequency compensation and superposition in time domain (SITD), based on the acoustic characteristics of the stiffener, to obtain a high-accuracy location result on the stiffener wall. According to the experimental results, the method successfully solves the orientation problem concerning continuous ultrasonic signals generated from leakage sources, and acquires high accuracy location information on the leakage source using a combination of multiple sets of orienting results. The mean value of location absolute error is 13.51 mm on the one-square-meter plate with an integral stiffener (4 mm width; 20 mm height; 197 mm spacing), and the maximum location absolute error is generally within a ±25 mm interval. PMID:26404316

  18. Alternative to Ph. Eur. pour-plate method for detection of microbial contamination in non-sterile pharmaceutical preparations.

    PubMed

    Palicz, A; Paul, A; Hofmann, A; Denzel, K

    2016-01-01

    The current European Pharmacopoeia (Ph. Eur.) texts for Interferon (IFN)-alfa-2 include a nonspecific photometric protein assay using albumin as calibrator and a highly variable cell-based assay for the potency determination of the protective effects. A request was expressed by the Official Medicines Control Laboratories (OMCLs) for improved methods for the batch control of recombinant interferon alfa-2 bulk and market surveillance testing of finished products, including those formulated with Human Serum Albumin (HSA). A HPLC method was developed at the Medical Products Agency (MPA, Sweden) for the testing of IFN-alfa-2 products. An initial collaborative study run under the Biological Standardisation Programme (BSP; study code BSP039) revealed the need for minor changes to improve linearity of the calibration curves, assay reproducibility and robustness. The goal of the collaborative study, coded BSP071, was to transfer and further validate this improved HPLC method. Ten laboratories participated in the study. Four marketed IFN-alfa-2 preparations (one containing HSA) together with the Ph. Eur. Chemical Reference Substance (CRS) for IFN-alfa-2a and IFN-alfa-2b, and in-house reference standards from two manufacturers were used for the quantitative assay. The modified method was successfully transferred to all laboratories despite local variation in equipment. The resolution between the main and the oxidised forms of IFN-alfa-2 was improved compared to the results from the BSP039 study. The improved method even allowed partial resolution of an extra peak after the principal peak. Symmetry of the main IFN peak was acceptable for all samples in all laboratories. Calibration curves established with the Ph. Eur. IFN-alfa-2a and IFN-alfa-2b CRSs showed excellent linearity with intercepts close to the origin and coefficients of determination greater than 0.9995. Assay repeatability, intermediate precision and reproducibility varied with the tested sample within acceptable

  19. Statistical tests of additional plate boundaries from plate motion inversions

    NASA Technical Reports Server (NTRS)

    Stein, S.; Gordon, R. G.

    1984-01-01

    The application of the F-ratio test, a standard statistical technique, to the results of relative plate motion inversions has been investigated. The method tests whether the improvement in fit of the model to the data resulting from the addition of another plate to the model is greater than that expected purely by chance. This approach appears to be useful in determining whether additional plate boundaries are justified. Previous results have been confirmed favoring separate North American and South American plates with a boundary located beween 30 N and the equator. Using Chase's global relative motion data, it is shown that in addition to separate West African and Somalian plates, separate West Indian and Australian plates, with a best-fitting boundary between 70 E and 90 E, can be resolved. These results are generally consistent with the observation that the Indian plate's internal deformation extends somewhat westward of the Ninetyeast Ridge. The relative motion pole is similar to Minster and Jordan's and predicts the NW-SE compression observed in earthquake mechanisms near the Ninetyeast Ridge.

  20. A simple plate-assay for screening extracellular naringinase produced by streptomycetes.

    PubMed

    Caraveo, Leonela; Medina, Héctor; Rodríguez-Buenfil, Ingrid; Montalvo-Romero, Carlos; Evangelista-Martínez, Zahaed

    2014-07-01

    A simple plate-assay was developed with the purpose of detecting extracellular naringinase in streptomycetes. The naringin agar medium (NAM) was prepared by mixing carbon utilization medium (ISP9) and naringin. The clearing zones around colonies are correlated with the enzymatic activity. The assay validation was performed through the use of commercial naringinase (Penicillium decumbens).