Science.gov

Sample records for agar plate method

  1. A modified agar plate method for detection of Strongyloides stercoralis.

    PubMed

    Koga, K; Kasuya, S; Khamboonruang, C; Sukhavat, K; Ieda, M; Takatsuka, N; Kita, K; Ohtomo, H

    1991-10-01

    The agar plate method is a new technique with high detection rates for coprological diagnosis of human strongyloidiasis. This report details modifications of the technique and establishes a standardized procedure. We recommend that all plates should be carefully observed using a microscope because macroscopic observation can lead to false negative results. It is also advisable to pour formalin solution directly into microscopically positive dishes to collect worms by sedimentation. This procedure enables one to observe worms otherwise hidden. Sealing dishes with adhesive tape prevents larvae from crawling out of the dishes, eliminating any possibility in the reduction of detection rates, and greatly improves the safety conditions for the technician performing the procedure. We consider the agar plate method to be superior to the filter paper method in detecting Strongyloides, and we believe that it will eventually become the technique of choice. PMID:1951861

  2. An Agar-Based Method for Plating Marine Protozoan Parasites of the Genus Perkinsus.

    PubMed

    Cold, Emma R; Freyria, Nastasia J; Martínez Martínez, Joaquín; Fernández Robledo, José A

    2016-01-01

    The genus Perkinsus includes protozoan parasites of mollusks responsible for losses in the aquaculture industry and hampering the recovery of natural shellfish beds worldwide, and they are a key taxon for understanding intracellular parasitism adaptations. The ability to propagate the parasite in liquid media, in the absence of the host, has been crucial for improving understanding of its biology; however, alternative techniques to grow the parasite are needed to explore other basic aspects of the Perkinsus spp. biology. We optimized a DME: Ham's F12-5% FBS- containing solid agar medium for plating Perkinsus marinus. This solid medium supported trophozoite propagation both by binary fission and schizogony. Colonies were visible to the naked eye 17 days after plating. We tested the suitability of this method for several applications, including the following: 1) Subcloning P. marinus isolates: single discrete P. marinus colonies were obtained from DME: Ham's F12-5% FBS- 0.75% agar plates, which could be further propagated in liquid medium; 2) Subcloning engineered Perkinsus mediterraneus MOE[MOE]: GFP by streaking cultures on plates; 3) Chemical susceptibility: Infusing the DME: Ham's F12-5% FBS- 0.75% agar plates with triclosan resulted in inhibition of the parasite propagation in a dose-dependent manner. Altogether, our plating method has the potential for becoming a key tool for investigating diverse aspects of Perkinsus spp. biology, developing new molecular tools, and for biotechnological applications.

  3. An Agar-Based Method for Plating Marine Protozoan Parasites of the Genus Perkinsus

    PubMed Central

    Cold, Emma R.; Freyria, Nastasia J.; Martínez Martínez, Joaquín; Fernández Robledo, José A.

    2016-01-01

    The genus Perkinsus includes protozoan parasites of mollusks responsible for losses in the aquaculture industry and hampering the recovery of natural shellfish beds worldwide, and they are a key taxon for understanding intracellular parasitism adaptations. The ability to propagate the parasite in liquid media, in the absence of the host, has been crucial for improving understanding of its biology; however, alternative techniques to grow the parasite are needed to explore other basic aspects of the Perkinsus spp. biology. We optimized a DME: Ham’s F12–5% FBS- containing solid agar medium for plating Perkinsus marinus. This solid medium supported trophozoite propagation both by binary fission and schizogony. Colonies were visible to the naked eye 17 days after plating. We tested the suitability of this method for several applications, including the following: 1) Subcloning P. marinus isolates: single discrete P. marinus colonies were obtained from DME: Ham’s F12–5% FBS– 0.75% agar plates, which could be further propagated in liquid medium; 2) Subcloning engineered Perkinsus mediterraneus MOE[MOE]: GFP by streaking cultures on plates; 3) Chemical susceptibility: Infusing the DME: Ham’s F12–5% FBS– 0.75% agar plates with triclosan resulted in inhibition of the parasite propagation in a dose-dependent manner. Altogether, our plating method has the potential for becoming a key tool for investigating diverse aspects of Perkinsus spp. biology, developing new molecular tools, and for biotechnological applications. PMID:27149378

  4. An Agar-Based Method for Plating Marine Protozoan Parasites of the Genus Perkinsus.

    PubMed

    Cold, Emma R; Freyria, Nastasia J; Martínez Martínez, Joaquín; Fernández Robledo, José A

    2016-01-01

    The genus Perkinsus includes protozoan parasites of mollusks responsible for losses in the aquaculture industry and hampering the recovery of natural shellfish beds worldwide, and they are a key taxon for understanding intracellular parasitism adaptations. The ability to propagate the parasite in liquid media, in the absence of the host, has been crucial for improving understanding of its biology; however, alternative techniques to grow the parasite are needed to explore other basic aspects of the Perkinsus spp. biology. We optimized a DME: Ham's F12-5% FBS- containing solid agar medium for plating Perkinsus marinus. This solid medium supported trophozoite propagation both by binary fission and schizogony. Colonies were visible to the naked eye 17 days after plating. We tested the suitability of this method for several applications, including the following: 1) Subcloning P. marinus isolates: single discrete P. marinus colonies were obtained from DME: Ham's F12-5% FBS- 0.75% agar plates, which could be further propagated in liquid medium; 2) Subcloning engineered Perkinsus mediterraneus MOE[MOE]: GFP by streaking cultures on plates; 3) Chemical susceptibility: Infusing the DME: Ham's F12-5% FBS- 0.75% agar plates with triclosan resulted in inhibition of the parasite propagation in a dose-dependent manner. Altogether, our plating method has the potential for becoming a key tool for investigating diverse aspects of Perkinsus spp. biology, developing new molecular tools, and for biotechnological applications. PMID:27149378

  5. A modified method for the detection of microbial proteases on agar plates using tannic acid.

    PubMed

    Saran, Saurabh; Isar, Jasmine; Saxena, Rajendra Kumar

    2007-06-10

    In routine assay for the screening of microbes producing proteases, 10% trichloroaceticacid (TCA) is flooded on the milk agar plates after inoculation and required incubation to precipitate the protein. However, the clarity of the hydrolyzed zone is not very sharp and distinct. We herein present an improved assay for detecting the presence of extracellular protease from microorganisms on agar plates. In this method 10% tannic acid is flooded on the milk agar plate (in place of, TCA) to observe the zone of hydrolysis. Tannic acid sharply increases the colour intensity of the plate, as it favours the precipitation of the unhydrolyzed protein in the plate, thereby improving the contrast between the intact zones and the enzymatic lyses zones of the substrate. Our results indicate that this method is useful to detect extracellular proteases produced by both fungi as well as bacteria. The method used in the present study is sensitive, and can be easily performed for screening of large number of microbial cultures. This is the first report on the use of tannic acid for the detection of microbial proteases.

  6. Evaluation of an automated agar plate streaker.

    PubMed Central

    Tilton, R C; Ryan, R W

    1978-01-01

    An automated agar plate streaker was evaluated. The Autostreaker mechanizes the agar plate streaking process by providing storage for plates, labeling and streaking one or more plates for either isolation or quantitation, and stacking in one of several racks for subsequent incubation. Results showed the Autostreaker to produce agar plates with well-separated colonies and accurate colony counts. A total of 1,930 clinical specimens were processed either in parallel with manual methods or solely by the Autostreaker. Technologist acceptance of machine-streaked plates was outstanding. Images PMID:348722

  7. Multiregional evaluation of the SimPlate heterotrophic plate count method compared to the standard plate count agar pour plate method in water.

    PubMed

    Jackson, R W; Osborne, K; Barnes, G; Jolliff, C; Zamani, D; Roll, B; Stillings, A; Herzog, D; Cannon, S; Loveland, S

    2000-01-01

    A new SimPlate heterotrophic plate count (HPC) method (IDEXX Laboratories, Westbrook, Maine) was compared with the pour plate method at 35 degrees C for 48 h. Six laboratories tested a total of 632 water samples. The SimPlate HPC method was found to be equivalent to the pour plate method by regression analysis (r = 0. 95; y = 0.99X + 0.06).

  8. Comparison of a novel MPN method against the yeast extract agar (YEA) pour plate method for the enumeration of heterotrophic bacteria from drinking water.

    PubMed

    Sartory, David P; Gu, Haoyi; Chen, Chun-Ming

    2008-07-01

    This study compared the Quanti-Disc most probable number (MPN) test for heterotrophic bacteria from drinking water with the widely used yeast extract agar (YEA) pour plate method. The Quanti-Disc test module contains 50 reaction wells in which a medium has been pre-deposited. The medium contains a suite of three fluorogenic enzyme substrates selected for the detection of enzymes expressed widely by heterotrophic bacteria. The MPN of heterotrophic bacteria is calculated from the number of fluorescing reaction wells after incubation of a sample. Quanti-Disc and the YEA pour plate method were compared according to guidance on comparing methods given in United Kingdom national guidance and ISO 17994:2004. The two methods were also challenged with reference strains and isolates of heterotrophic bacteria from drinking water. This indicated that heterotrophic bacteria commonly encountered in drinking water are detected by both the YEA pour plate method and Quanti-Disc. Analysis of data from split water samples (723 for 37 degrees C tests and 872 for 22 degrees C tests) from nine geographically diverse laboratories in England and Wales demonstrated that the Quanti-Disc method is equivalent to the YEA pour plate method for the analysis of heterotrophic bacteria from drinking and similar waters at 37 degrees C, and superior to YEA for the analysis at 22 degrees C. The Quanti-Disc method is a simple and efficient alternative method for the enumeration of heterotrophic bacteria from drinking water.

  9. Syneresis and delayed detachment in agar plates

    NASA Astrophysics Data System (ADS)

    Divoux, Thibaut; Mao, Bosi; Snabre, Patrick

    Biogels made of crosslinked polymers such as proteins or polysaccharides behave as porous soft solids and store large amount of solvent. These gels undergo spontaneous aging, called syneresis that consists in the shrinkage of the gel matrix and the progressive expulsion of the solvent. As a result, a biogel originally casted in a container often lose contact with the container sidewalls, and the detachment time is a priori difficult to anticipate since it may occur over variable time spans (from hours to days). Here we report on the syneresis phenomena in agar plates that consist in Petri dishes filled with a gel mainly composed of agar. Direct observations and speckle pattern correlation analysis allow us to rationalize the delayed detachment of the gel from the sidewall of the Petri dish. The detachment time $t^*$ is surprisingly not controlled by the mass loss as one would intuitively expect. Instead, $t^*$ is strongly correlated to the gel minimum thickness $e_{min}$ measured along the sidewall of the plate, and increases as a robust function of $e_{min}$ independently of the prior mass-loss history. Time-resolved correlation spectroscopy atypically applied to such weakly diffusive media gives access to the local thinning rate of the gel. This technique also allows us to detect the gel micro-displacements that are triggered by the water evaporation prior to the detachment, and even to anticipate the latter from a few hours. Our work provides observables to predict the detachment time of agar gels in dishes, and highlights the relevance of speckle pattern correlation analysis for the quantitative investigation of the syneresis dynamics in biopolymer gels.

  10. Syneresis and delayed detachment in agar plates.

    PubMed

    Divoux, Thibaut; Mao, Bosi; Snabre, Patrick

    2015-05-14

    Biogels made of crosslinked polymers such as proteins or polysaccharides behave as porous soft solids and store large amounts of solvent. These gels undergo spontaneous aging, called syneresis, which consists of the shrinkage of the gel matrix and the progressive expulsion of solvent. As a result, a biogel originally casted in a container often loses contact with the container sidewalls, and the detachment time is difficult to anticipate a priori, since it may occur over variable time spans (from hours to days). Here we report on syneresis phenomena in agar plates, which consist of Petri dishes filled with a gel mainly composed of agar. Direct observations and speckle pattern correlation analysis allow us to rationalize the delayed detachment of the gel from the sidewall of the Petri dish. The detachment time t* is surprisingly not controlled by the mass loss as one would intuitively expect. Instead, t* is strongly correlated to the gel minimum thickness emin measured along the sidewall of the plate, and increases as a robust function of emin, independently of the prior mass-loss history. Time-resolved correlation spectroscopy atypically applied to such weakly diffusive media gives access to the local thinning rate of the gel. This technique also allows us to detect the gel micro-displacements that are triggered by water evaporation prior to the detachment, and even to anticipate the latter from a few hours. Our work provides observables to predict the detachment time of agar gels in dishes, and highlights the relevance of speckle pattern correlation analysis for the quantitative investigation of the syneresis dynamics in biopolymer gels.

  11. Syneresis and delayed detachment in agar plates.

    PubMed

    Divoux, Thibaut; Mao, Bosi; Snabre, Patrick

    2015-05-14

    Biogels made of crosslinked polymers such as proteins or polysaccharides behave as porous soft solids and store large amounts of solvent. These gels undergo spontaneous aging, called syneresis, which consists of the shrinkage of the gel matrix and the progressive expulsion of solvent. As a result, a biogel originally casted in a container often loses contact with the container sidewalls, and the detachment time is difficult to anticipate a priori, since it may occur over variable time spans (from hours to days). Here we report on syneresis phenomena in agar plates, which consist of Petri dishes filled with a gel mainly composed of agar. Direct observations and speckle pattern correlation analysis allow us to rationalize the delayed detachment of the gel from the sidewall of the Petri dish. The detachment time t* is surprisingly not controlled by the mass loss as one would intuitively expect. Instead, t* is strongly correlated to the gel minimum thickness emin measured along the sidewall of the plate, and increases as a robust function of emin, independently of the prior mass-loss history. Time-resolved correlation spectroscopy atypically applied to such weakly diffusive media gives access to the local thinning rate of the gel. This technique also allows us to detect the gel micro-displacements that are triggered by water evaporation prior to the detachment, and even to anticipate the latter from a few hours. Our work provides observables to predict the detachment time of agar gels in dishes, and highlights the relevance of speckle pattern correlation analysis for the quantitative investigation of the syneresis dynamics in biopolymer gels. PMID:25812667

  12. Development of a selective agar plate for the detection of Campylobacter spp. in fresh produce.

    PubMed

    Yoo, Jin-Hee; Choi, Na-Young; Bae, Young-Min; Lee, Jung-Su; Lee, Sun-Young

    2014-10-17

    This study was conducted to develop a selective medium for the detection of Campylobacter spp. in fresh produce. Campylobacter spp. (n=4), non-Campylobacter (showing positive results on Campylobacter selective agar) strains (n=49) isolated from fresh produce, indicator bacteria (n=13), and spoilage bacteria isolated from fresh produce (n=15) were plated on four Campylobacter selective media. Bolton agar and modified charcoal cefoperazone deoxycholate agar (mCCDA) exhibited higher sensitivity for Campylobacter spp. than did Preston agar and Hunt agar, although certain non-Campylobacter strains isolated from fresh produce by using a selective agar isolation method, were still able to grow on Bolton agar and mCCDA. To inhibit the growth of non-Campylobacter strains, Bolton agar and mCCDA were supplemented with 5 antibiotics (rifampicin, polymyxin B, sodium metabisulfite, sodium pyruvate, ferrous sulfate) and the growth of Campylobacter spp. (n=7) and non-Campylobacter strains (n=44) was evaluated. Although Bolton agar supplemented with rifampicin (BR agar) exhibited a higher selectivity for Campylobacter spp. than did mCCDA supplemented with antibiotics, certain non-Campylobacter strains were still able to grow on BR agar (18.8%). When BR agar with various concentrations of sulfamethoxazole-trimethoprim were tested with Campylobacter spp. (n=8) and non-Campylobacter (n=7), sulfamethoxazole-trimethoprim was inhibitory against 3 of 7 non-Campylobacter strains. Finally, we validated the use of BR agar containing 50mg/L sulfamethoxazole (BRS agar) or 0.5mg/L ciprofloxacin (BRCS agar) and other selective agars for the detection of Campylobacter spp. in chicken and fresh produce. All chicken samples were positive for Campylobacter spp. when tested on mCCDA, BR agar, and BRS agar. In fresh produce samples, BRS agar exhibited the highest selectivity for Campylobacter spp., demonstrating its suitability for the detection of Campylobacter spp. in fresh produce.

  13. Automated counting of bacterial colony forming units on agar plates.

    PubMed

    Brugger, Silvio D; Baumberger, Christian; Jost, Marcel; Jenni, Werner; Brugger, Urs; Mühlemann, Kathrin

    2012-01-01

    Manual counting of bacterial colony forming units (CFUs) on agar plates is laborious and error-prone. We therefore implemented a colony counting system with a novel segmentation algorithm to discriminate bacterial colonies from blood and other agar plates.A colony counter hardware was designed and a novel segmentation algorithm was written in MATLAB. In brief, pre-processing with Top-Hat-filtering to obtain a uniform background was followed by the segmentation step, during which the colony images were extracted from the blood agar and individual colonies were separated. A Bayes classifier was then applied to count the final number of bacterial colonies as some of the colonies could still be concatenated to form larger groups. To assess accuracy and performance of the colony counter, we tested automated colony counting of different agar plates with known CFU numbers of S. pneumoniae, P. aeruginosa and M. catarrhalis and showed excellent performance.

  14. Replica plating of colonies from Listeria-selective agars to blood agar to improve the isolation of Listeria monocytogenes from foods.

    PubMed

    Cassiday, P K; Graves, L M; Swaminathan, B

    1990-07-01

    Bacterial colonies from Listeria-selective agars were replica plated to sheep blood agar to screen for beta-hemolysis. By using the replica plating method to test for the beta-hemolytic characteristic of all the colonies growing on Listeria-selective agars instead of picking 3 to 10 suspected colonies for further testing, we recovered Listeria monocytogenes from 59 of 142 Listeria-selective agar plates which contained colonies of hemolytic and nonhemolytic Listeria species and were negative when tested by conventional colony picks.

  15. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  16. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  17. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  18. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  19. 21 CFR 866.4600 - Ouchterlony agar plate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ouchterlony agar plate. 866.4600 Section 866.4600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents §...

  20. Evaluation of Granada agar plate for detection of Streptococcus agalactiae in urine specimens from pregnant women.

    PubMed

    Tamayo, Javier; Gómez-Garcés, José-Luis; Alós, Juan-Ignacio

    2004-08-01

    The Granada agar plate (GAP; Biomedics SL, Madrid, Spain) was evaluated for the detection of group B streptococci (GBS) in urine specimens from pregnant women submitted for testing for asymptomatic bacteriuria and was compared with blood agar (BA [Columbia agar with 5% sheep blood]; bioMérieux, Marcy l'Etoile, France). The GAP detected 103 out of 105 GBS, whereas BA detected only 50. Use of the GAP could be a good method for the detection of GBS in urine specimens from pregnant women. PMID:15297542

  1. Hyperspectral image reconstruction using RGB color for foodborne pathogen detection on agar plates

    NASA Astrophysics Data System (ADS)

    Yoon, Seung-Chul; Shin, Tae-Sung; Park, Bosoon; Lawrence, Kurt C.; Heitschmidt, Gerald W.

    2014-03-01

    This paper reports the latest development of a color vision technique for detecting colonies of foodborne pathogens grown on agar plates with a hyperspectral image classification model that was developed using full hyperspectral data. The hyperspectral classification model depended on reflectance spectra measured in the visible and near-infrared spectral range from 400 and 1,000 nm (473 narrow spectral bands). Multivariate regression methods were used to estimate and predict hyperspectral data from RGB color values. The six representative non-O157 Shiga-toxin producing Eschetichia coli (STEC) serogroups (O26, O45, O103, O111, O121, and O145) were grown on Rainbow agar plates. A line-scan pushbroom hyperspectral image sensor was used to scan 36 agar plates grown with pure STEC colonies at each plate. The 36 hyperspectral images of the agar plates were divided in half to create training and test sets. The mean Rsquared value for hyperspectral image estimation was about 0.98 in the spectral range between 400 and 700 nm for linear, quadratic and cubic polynomial regression models and the detection accuracy of the hyperspectral image classification model with the principal component analysis and k-nearest neighbors for the test set was up to 92% (99% with the original hyperspectral images). Thus, the results of the study suggested that color-based detection may be viable as a multispectral imaging solution without much loss of prediction accuracy compared to hyperspectral imaging.

  2. Comparing the mannitol-egg yolk-polymyxin agar plating method with the three-tube most-probable-number method for enumeration of Bacillus cereus spores in raw and high-temperature, short-time pasteurized milk.

    PubMed

    Harper, Nigel M; Getty, Kelly J K; Schmidt, Karen A; Nutsch, Abbey L; Linton, Richard H

    2011-03-01

    The U.S. Food and Drug Administration's Bacteriological Analytical Manual recommends two enumeration methods for Bacillus cereus: (i) standard plate count method with mannitol-egg yolk-polymyxin (MYP) agar and (ii) a most-probable-number (MPN) method with tryptic soy broth (TSB) supplemented with 0.1% polymyxin sulfate. This study compared the effectiveness of MYP and MPN methods for detecting and enumerating B. cereus in raw and high-temperature, short-time pasteurized skim (0.5%), 2%, and whole (3.5%) bovine milk stored at 4°C for 96 h. Each milk sample was inoculated with B. cereus EZ-Spores and sampled at 0, 48, and 96 h after inoculation. There were no differences (P > 0.05) in B. cereus populations among sampling times for all milk types, so data were pooled to obtain overall mean values for each treatment. The overall B. cereus population mean of pooled sampling times for the MPN method (2.59 log CFU/ml) was greater (P < 0.05) than that for the MYP plate count method (1.89 log CFU/ml). B. cereus populations in the inoculated milk samples ranged from 2.36 to 3.46 and 2.66 to 3.58 log CFU/ml for inoculated milk treatments for the MYP plate count and MPN methods, respectively, which is below the level necessary for toxin production. The MPN method recovered more B. cereus, which makes it useful for validation research. However, the MYP plate count method for enumeration of B. cereus also had advantages, including its ease of use and faster time to results (2 versus 5 days for MPN).

  3. Agar underlay method for recovery of sublethally heat-injured bacteria.

    PubMed

    Kang, D H; Siragusa, G R

    1999-12-01

    A method of recovering sublethally heat-injured bacteria was developed. The procedure (termed the agar underlay method) uses a nonselective agar underlaid with a selective medium. In a two-chambered petri dish, the Lutri plate (LP), a nonselective agar is inoculated with a population of sublethally heat-injured bacteria. After a 2-h repair incubation period, selective agar is added to the bottom chamber of the LP and incubated. By diffusing through the nonselective top agar, selective agents from the underlay medium impart selectivity to the system. By the agar underlay method, recovery rates of the heat-injured food-borne pathogens Escherichia coli O157:H7 and Salmonella typhimurium were not different (P > 0. 05) from recovery rates determined with nonselective media. Sublethally heat-injured cells (60 degrees C for 1.5 min in buffer or 80 degrees C for 30 s on meat surfaces) grew and produced a typical colony morphology and color reaction when the agar underlay procedure was used with the appropriate respective selective agars. Unlike agar overlay methods for injury repair, the agar underlay procedure allows the typical selective-medium colony morphology to develop and allows colonies to be more easily picked for further characterization. Higher recovery rates of heat-injured fecal enterococci from bovine fecal samples and total coliforms from animal waste lagoons were obtained by the agar underlay method with selective agars than by direct plating on the respective selective media. PMID:10583985

  4. Evaluation of Petrifilm™ aerobic count plates as an equivalent alternative to drop plating on R2A agar plates in a biofilm disinfectant efficacy test.

    PubMed

    Fritz, B G; Walker, D K; Goveia, D E; Parker, A E; Goeres, D M

    2015-03-01

    This paper compares Petrifilm™ aerobic count (AC) plates to drop plating on R2A agar plates as an alternative method for biofilm bacteria enumeration after application of a disinfectant. A Pseudomonas aeruginosa biofilm was grown in a Centers for Disease Control and Prevention biofilm reactor (ASTM E2562) and treated with 123 ppm sodium hypochlorite (as free chlorine) according to the Single Tube Method (ASTM E2871). Aliquots from the same dilution tubes were plated on Petrifilm™ AC plates and drop plated on R2A agar plates. The Petrifilm™ AC and R2A plates were incubated for 48 and 24 h, respectively, at 36 ± 1 °C. After nine experimental runs performed by two technicians, the mean difference in biofilm log densities [log biofilm density (LD) = log10(CFU/cm(2))] between the two methods for control coupons, treated coupons, and log reduction (LR) was 0.052 (p = 0.451), -0.102 (p = 0.303), and 0.152 (p = 0.313). Equivalence testing was used to assess equivalence of the two plating methods. The 90 % confidence intervals for the difference in control and treated mean LDs between methods were (-0.065, 0.170) and (-0.270, 0.064), both of which fall within a (-0.5, +0.5) equivalence criterion. The 90 % confidence interval for the mean LR difference (-0.113, 0.420) also falls within this equivalence criterion. Thus, Petrifilm™ AC plates were shown to be statistically equivalent to drop plating on R2A agar for the determination of control LDs, treated LDs, and LR values in an anti-biofilm efficacy test. These are the first published results that establish equivalency to a traditional plate counting technique for biofilms and for a disinfectant assay.

  5. Application of Microbiological Method Direct Epifluorescence Filter Techique/Aerobic Plate Count Agar in the Identification of Irradiated Herbs and Spices

    PubMed Central

    Di Schiavi, Maria Teresa; Foti, Marina; Mosconi, Maria Cristina; Mattiolo, Giuseppina; Cavallina, Roberta

    2014-01-01

    Irradiation is a preservation technology used to improve the safety and hygienic quality of food. Aim of this study was to assess the applicability and validity of the microbiological screening method direct epifluorescence filter technique (DEFT)/aerobic plate count (APC) (EN 13783:2001) for the identification of irradiated herbs and spices. Tests on non-irradiated and irradiated samples of dried herbs and spices were performed. The method was based on the comparison of APC and count obtained using DEFT. In accordance with the standard reference, this method is not applicable to samples with APC<103 colony forming units (CFU)/g and this is its main limit. The results obtained in our laboratories showed that in 50% of cases of non-irradiated samples and in 96% of the samples treated with ionising radiation, the method was not applicable due to a value of CFU/g <103. PMID:27800348

  6. Efficacy of agar-plate culture in detection of Strongyloides stercoralis infection.

    PubMed

    Arakaki, T; Iwanaga, M; Kinjo, F; Saito, A; Asato, R; Ikeshiro, T

    1990-06-01

    Agar-plate culture of feces using a modified petri dish proved to be highly efficient in the detection of Strongyloides stercoralis infection. Furrows left by S. stercoralis on the agar plate were distinguished readily in size from those left by Necator americanus. PMID:2352073

  7. Simulation of Bacillus subtilis biofilm growth on agar plate by diffusion–reaction based continuum model

    NASA Astrophysics Data System (ADS)

    Zhang, Xianlong; Wang, Xiaoling; Nie, Kai; Li, Mingpeng; Sun, Qingping

    2016-08-01

    Various species of bacteria form highly organized spatially-structured aggregates known as biofilms. To understand how microenvironments impact biofilm growth dynamics, we propose a diffusion–reaction continuum model to simulate the formation of Bacillus subtilis biofilm on an agar plate. The extended finite element method combined with level set method are employed to perform the simulation, numerical results show the quantitative relationship between colony morphologies and nutrient depletion over time. Considering that the production of polysaccharide in wild-type cells may enhance biofilm spreading on the agar plate, we inoculate mutant colony incapable of producing polysaccharide to verify our results. Predictions of the glutamate source biofilm’s shape parameters agree with the experimental mutant colony better than that of glycerol source biofilm, suggesting that glutamate is rate limiting nutrient for Bacillus subtilis biofilm growth on agar plate, and the diffusion-limited is a better description to the experiment. In addition, we find that the diffusion time scale is of the same magnitude as growth process, and the common-employed quasi-steady approximation is not applicable here.

  8. Simulation of Bacillus subtilis biofilm growth on agar plate by diffusion-reaction based continuum model.

    PubMed

    Zhang, Xianlong; Wang, Xiaoling; Nie, Kai; Li, Mingpeng; Sun, Qingping

    2016-01-01

    Various species of bacteria form highly organized spatially-structured aggregates known as biofilms. To understand how microenvironments impact biofilm growth dynamics, we propose a diffusion-reaction continuum model to simulate the formation of Bacillus subtilis biofilm on an agar plate. The extended finite element method combined with level set method are employed to perform the simulation, numerical results show the quantitative relationship between colony morphologies and nutrient depletion over time. Considering that the production of polysaccharide in wild-type cells may enhance biofilm spreading on the agar plate, we inoculate mutant colony incapable of producing polysaccharide to verify our results. Predictions of the glutamate source biofilm's shape parameters agree with the experimental mutant colony better than that of glycerol source biofilm, suggesting that glutamate is rate limiting nutrient for Bacillus subtilis biofilm growth on agar plate, and the diffusion-limited is a better description to the experiment. In addition, we find that the diffusion time scale is of the same magnitude as growth process, and the common-employed quasi-steady approximation is not applicable here. PMID:27434099

  9. Simulation of Bacillus subtilis biofilm growth on agar plate by diffusion-reaction based continuum model

    NASA Astrophysics Data System (ADS)

    Zhang, Xianlong; Wang, Xiaoling; Nie, Kai; Li, Mingpeng; Sun, Qingping

    2016-08-01

    Various species of bacteria form highly organized spatially-structured aggregates known as biofilms. To understand how microenvironments impact biofilm growth dynamics, we propose a diffusion-reaction continuum model to simulate the formation of Bacillus subtilis biofilm on an agar plate. The extended finite element method combined with level set method are employed to perform the simulation, numerical results show the quantitative relationship between colony morphologies and nutrient depletion over time. Considering that the production of polysaccharide in wild-type cells may enhance biofilm spreading on the agar plate, we inoculate mutant colony incapable of producing polysaccharide to verify our results. Predictions of the glutamate source biofilm’s shape parameters agree with the experimental mutant colony better than that of glycerol source biofilm, suggesting that glutamate is rate limiting nutrient for Bacillus subtilis biofilm growth on agar plate, and the diffusion-limited is a better description to the experiment. In addition, we find that the diffusion time scale is of the same magnitude as growth process, and the common-employed quasi-steady approximation is not applicable here.

  10. Digital image quantification of siderophores on agar plates.

    PubMed

    Andrews, Megan Y; Santelli, Cara M; Duckworth, Owen W

    2016-03-01

    This article presents visual image data and detailed methodology for the use of a new method for quantifying the exudation of siderophores during fungal growth. The data include images showing time series for calibration, fungal exudation, and negative controls, as well as replication accuracy information. In addition, we provide detailed protocols for making CAS assay layer plates, the digital analysis protocol for determining area of color change, and discuss growth media that do and do not work with the layer plate method. The results of these data, their interpretation, and further discussion can be found in Andrews et al., 2016 [1]. PMID:26937467

  11. Ceftibuten-containing agar plate for detecting group B streptococci with reduced penicillin susceptibility (PRGBS).

    PubMed

    Kamiya, Chitose; Kimura, Kouji; Doyama, Yo; Miyazaki, Akira; Morimoto, Makiko; Banno, Hirotsugu; Nagano, Noriyuki; Jin, Wanchun; Wachino, Jun-ichi; Yamada, Keiko; Arakawa, Yoshichika

    2015-08-01

    Penicillins remain first-line agents for treatment of group B Streptococcus (Streptococcus agalactiae; GBS) infections; however, several reports have confirmed the existence of GBS with reduced penicillin susceptibility (PRGBS). Because no selective agar plates for detection of PRGBS are available to date, in this investigation, we developed the selective agar plate for detection of PRGBS. We used 19 genetically well-confirmed PRGBS isolates and 38 penicillin-susceptible GBS isolates identified in Japan. For preparation of trial PRGBS-selective agar plates, we added 1 of antimicrobial agents (among oxacillin, ceftizoxime, and ceftibuten) to a well-established GBS-selective agar plate. Among 12 trial PRGBS-selective agar plates, Muller-Hinton agar containing 128 μg/mL ceftibuten with 5% sheep blood, 8 μg/mL gentamicin, and 12 μg/mL nalidixic acid was the most appropriate selective agar for PRGBS, showing 100% sensitivity and 81.6% specificity. In cases of potential nosocomial spread of PRGBS, the selective agar plate could be useful and reliable.

  12. A solid agar overlay method for recovery of heat-injured Listeria monocytogenes.

    PubMed

    Yan, Zhinong; Gurtler, Joshua B; Kornacki, Jeffrey L

    2006-02-01

    A solid agar overlay method was developed for recovery of heat-injured Listeria monocytogenes. Presolidified nonselective tryptic soy agar with 0.6% yeast extract (TSAYE, 2% agar) was overlaid on top of solidified modified Oxford agar (MOX). Heat injury of L. monocytogenes was conducted at 58 degrees C for 6 min in a jacketed flask filled with tryptic soy broth. Both noninjured and heat-treated L. monocytogenes cells were plated onto TSAYE, MOX, and TSAYE-MOX plates. No significant differences (P > 0.05) in recovery were found among the three media for noninjured bacterial cells. Recovery of heat-injured L. monocytogenes cells on TSAYE-MOX overlay plates was equivalent to that on the nonselective TSAYE medium, whereas recovery on the selective MOX medium was significantly lower (P < 0.05) compared with both TSAYE and the overlay plates. There were no significant differences (P > 0.05) among the overlay plates prepared 0, 2, 4, 6, 8, 16, and 24 h prior to plating heat-injured bacterial cells. The TSAYE-MOX overlay also allowed differentiation of L. monocytogenes from a mixture of four other types of foodborne pathogens. This solid agar overlay method for recovery of heat-injured L. monocytogenes cells is less time-consuming and less complicated than the conventional overlay-underlay technique and the double overlay modification of the thin agar layer method and may allow for greater laboratory plating efficiencies.

  13. An extension of the Coconut Cream Agar method to screen Penicillium citrinum isolates for citrinin production.

    PubMed

    Mohamed, S; Flint, S; Palmer, J; Fletcher, G C; Pitt, J I

    2013-09-01

    A simple and rapid screening method was developed for the detection of citrinin in fungal cultures using Coconut Cream Agar (CCA) described previously for detecting aflatoxin and ochratoxin A. Fifteen isolates of Penicillium citrinum were inoculated onto CCA and incubated at 25 and 30°C for 10 days. All isolates produced a distinct yellow green fluorescence on CCA when the reverse side of the agar plates were viewed under long wavelength UV light. Detection was optimal at 25°C after four to 5 days of incubation. Isolates positive by the CCA method also tested positive for citrinin production by the TLC agar plug method after growth on CCA, Czapek yeast extract agar and yeast extract sucrose agar. Control cultures were negative by both methods, indicating that the CCA Petri dish method was suitable for screening cultures for citrinin production.

  14. Visualization of Biosurfactant Film Flow in a Bacillus subtilis Swarm Colony on an Agar Plate.

    PubMed

    Kim, Kyunghoon; Kim, Jung Kyung

    2015-01-01

    Collective bacterial dynamics plays a crucial role in colony development. Although many research groups have studied the behavior of fluidic swarm colonies, the detailed mechanics of its motion remains elusive. Here, we developed a visualization method using submicron fluorescent beads for investigating the flow field in a thin layer of fluid that covers a Bacillus subtilis swarm colony growing on an agar plate. The beads were initially embedded in the agar plate and subsequently distributed spontaneously at the upper surface of the expanding colony. We conducted long-term live cell imaging of the B. subtilis colony using the fluorescent tracers, and obtained high-resolution velocity maps of microscale vortices in the swarm colony using particle image velocimetry. A distinct periodic fluctuation in the average speed and vorticity of flow in swarm colony was observed at the inner region of the colony, and correlated with the switch between bacterial swarming and growth phases. At the advancing edge of the colony, both the magnitudes of velocity and vorticity of flow in swarm colony were inversely correlated with the spreading speed of the swarm edge. The advanced imaging tool developed in this study would facilitate further understanding of the effect of micro vortices in swarm colony on the collective dynamics of bacteria. PMID:26343634

  15. Visualization of Biosurfactant Film Flow in a Bacillus subtilis Swarm Colony on an Agar Plate

    PubMed Central

    Kim, Kyunghoon; Kim, Jung Kyung

    2015-01-01

    Collective bacterial dynamics plays a crucial role in colony development. Although many research groups have studied the behavior of fluidic swarm colonies, the detailed mechanics of its motion remains elusive. Here, we developed a visualization method using submicron fluorescent beads for investigating the flow field in a thin layer of fluid that covers a Bacillus subtilis swarm colony growing on an agar plate. The beads were initially embedded in the agar plate and subsequently distributed spontaneously at the upper surface of the expanding colony. We conducted long-term live cell imaging of the B. subtilis colony using the fluorescent tracers, and obtained high-resolution velocity maps of microscale vortices in the swarm colony using particle image velocimetry. A distinct periodic fluctuation in the average speed and vorticity of flow in swarm colony was observed at the inner region of the colony, and correlated with the switch between bacterial swarming and growth phases. At the advancing edge of the colony, both the magnitudes of velocity and vorticity of flow in swarm colony were inversely correlated with the spreading speed of the swarm edge. The advanced imaging tool developed in this study would facilitate further understanding of the effect of micro vortices in swarm colony on the collective dynamics of bacteria. PMID:26343634

  16. Evaluation of blood agar microtiter plates for culturing leishmania parasites to titrate parasite burden in spleen and peripheral blood of patients with visceral leishmaniasis.

    PubMed

    Maurya, Radheshyam; Mehrotra, Sanjana; Prajapati, Vijay Kumar; Nylén, Susanne; Sacks, David; Sundar, Shyam

    2010-05-01

    Serial dilution of blood and spleen biopsy specimens, plated on Novy-MacNeal-Nicolle (NNN) blood agar using microtiter culture plates, is a sensitive and reproducible method for detection and growth of Leishmania parasites. Plates could be easily monitored, and growth could be rapidly detected. Moreover, parasite number may be estimated using this technique.

  17. Detection of bacterioplankton in immersed cadavers using selective agar plates.

    PubMed

    Kakizaki, Eiji; Kozawa, Shuji; Tashiro, Noriko; Sakai, Masahiro; Yukawa, Nobuhiro

    2009-04-01

    We measured bacterioplankton in blood from cadavers retrieved from the sea (n=12), near estuaries (n=4), rivers (fresh water, n=8) and from bathtubs (n=4) as well as from non-drowned victims (n=10) discovered near aquatic environments. Blood from 11 victims drowned in seawater developed bioluminescent and/or blue colonies (oxidase test positive) on selective media containing 2-4% NaCl. Homology analyses of the 16S rRNA gene showed that all of them were marine bacteria (genera: Photobacterium, Vibrio, Shewanella, Psychrobacter). Blood from all victims drowned in rivers generated blue colonies on plates containing 3%, but not 4% NaCl. Homology analyses showed that the blue colonies were generated from bacteria that inhabit fresh water (Aeromonas). None of the blood samples from victims that drowned in bathtubs generated bioluminescent and blue colonies. However, all cadavers contained bacteria that produced unstained colonies (Staphylococcus, Bacillus, Enterobacter, Escherichia, etc.). Among non-drowned victims, blood from two gave rise to blue colonies on plates containing < or =3% NaCl (Pseudomonas). Of the cadavers found near estuaries, bioluminescent and blue colonies developed from two of them on media containing 2-4% NaCl (Photobacterium, Vibrio, Listonella), but not from two others on plates containing 4% NaCl (at < or =3%; blue colonies, Aeromonas; unstained colonies, Citrobacter, Vagococcus, Proteus, Enterobacter). These results suggested that the presence of numerous bacterioplankton in immersed cadavers could support a conclusion of death by drowning.

  18. Screening fungicides for use in fish culture: Evaluation of the agar plug transfer, cellophane transfer, and agar dilution methods

    USGS Publications Warehouse

    Bailey, Tom A.

    1983-01-01

    The reliability, reproducibility, and usefulness of three screening methods -- the cellophane transfer, the agar plug transfer, and the agar dilution -- to screen aquatic fungicides were evaluated. Achlya flagellata and Saprolegnia hypogyna were exposed to 1, 10, and 100 mg/L of malachite green to test each method. The cellophane transfer and agar plug transfer techniques had similar reliability and reproducibility in rating fungicidal activity, and were both superior to the agar dilution technique. The agar plug transfer and agar dilution techniques adequately projected in vivo activity of malachite green, but the cellophane transfer technique overestimated its activity. Overall, the agar plug transfer technique most accurately rated the activity of malachite green and was the easiest test to perform. It therefore appears to be the method of choice for testing aquatic fungicides.

  19. Thallium toxicosis in a dog consequent to ingestion of Mycoplasma agar plates.

    PubMed

    Puschner, Birgit; Basso, Marguerite M; Graham, Thomas W

    2012-01-01

    A 1-year-old dog ingested a mixture of blood agar and Mycoplasma agar plates. The Mycoplasma agar plates contained thallium acetate, which resulted in an estimated minimum dose of 5 mg thallium acetate/kg bodyweight. Clinical signs over the course of 2-3 weeks included vomiting, diarrhea, weight loss, alopecia, dysphonia, ataxia, paresthesia, intension tremors, megaesophagus with subsequent aspiration pneumonia, and several seizure episodes. The dog was treated with intravenous fluids and placement of a gastric feeding tube. Thallium concentrations in hair were 8.2 µg/g in samples taken on day 19, 16.4 µg/g in samples taken 3 months after exposure, 13.4 µg/g in samples taken 5 months after exposure, and nondetectable in samples taken 7 months after exposure. The blood thallium concentration was 190 µg/l on day 19 and nondetec table 3 months after exposure. Megaesophagus and dysphonia continued for 10 months after exposure. This case of thallium poisoning following ingestion of mycoplasma agar plates demonstrates that unusual sources of thallium still exist and suggests that thallium toxicosis should be included in the list of differential diagnoses in dogs presented with megaesophagus, especially if alopecia and other unexplained peripheral neuropathies are present. Hair and blood samples are useful specimens to reach an accurate diagnosis even if taken several weeks post exposure. The postexposure blood and hair thallium concentrations reported in this case are useful data for diagnosticians investigating dogs with potential thallium poisoning.

  20. Time- and media-saving testing and identification of microorganisms by multipoint inoculation on undivided agar plates.

    PubMed Central

    Burman, L G; Ostensson, R

    1978-01-01

    Motility and various biochemical activities of isolates of bacteria and yeasts were tested on undivided agar plates by using a simple, manually operated multipoint inoculation apparatus that allowed the analysis of 25 isolates per 9-cm-diameter petri plate. Fermentation of all 17 carbohydrates tested as well as 13 other biochemical activities commonly used for identification of bacteria were readily demonstrated by the multipoint inoculation plate method, and the results agreed very well with those of conventional tube tests. In addition to speedy inoculation and low cost of materials, the multipoint inoculation plate method offers several other advantages when compared with conventional tube tests or with some of the manufactured test kits currently available for recognizing members of the family Enterobacteriaceae. Images PMID:359588

  1. Aseptic laboratory techniques: plating methods.

    PubMed

    Sanders, Erin R

    2012-05-11

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: Perform plating procedures without contaminating media. Isolate single bacterial colonies by the streak-plating

  2. Aseptic Laboratory Techniques: Plating Methods

    PubMed Central

    Sanders, Erin R.

    2012-01-01

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: ● Perform plating procedures without contaminating media. ● Isolate single bacterial colonies by the

  3. Broth and agar hop-gradient plates used to evaluate the beer-spoilage potential of Lactobacillus and Pediococcus isolates.

    PubMed

    Haakensen, M; Schubert, A; Ziola, B

    2009-03-15

    Identification of the beer-spoilage Lactobacillus and Pediococcus bacteria has largely taken two approaches; identification of spoilage-associated genes or identification of specific species of bacteria regardless of ability to grow in beer. The problem with these two approaches is that they are either overly inclusive (i.e., detect all bacteria of a given species regardless of spoilage potential) or overly selective (i.e., rely upon individual, putative spoilage-associated genes). Our goal was to design a method to assess the ability of Lactobacillus and Pediococcus to spoil beer that is independent of speciation or genetic background. In searching for a method by which to differentiate between beer-spoilage bacteria and bacteria that cannot grow in beer, we explored the ability of lactobacilli and pediococci isolates to grow in the presence of varying concentrations of hop-compounds and ethanol in broth medium versus on agar medium. The best method for differentiating between bacteria that can grow in beer and bacteria that do not pose a threat as beer-spoilage organisms was found to be a hop-gradient agar plate containing ethanol. This hop-gradient agar plate technique provides a rapid and simple solution to the dilemma of assessing the ability of Lactobacillus and Pediococcus isolates to grow in beer, and provides new insights into the different strategies used by these bacteria to survive under the stringent conditions of beer.

  4. Method for Measuring Changes in Surface Tension on Agar

    PubMed Central

    Weisberg, David S.; Dworkin, Martin

    1983-01-01

    The surface tension of agar surfaces was determined by measuring the contact angles formed by drops of various hydrophobic liquids on the surface and then calculating the composite surface free energy function by solving a series of simultaneous equations derived from these data. This method was used to measure the change in the surface tension of agar produced by the addition of various concentrations of albumin. The resulting curve was typical of the effect of increasing concentrations of surfactants on surface tension. The method was compared with other methods of determining surface tension of solids, and it was concluded that the technique used here provided the most reliable results. PMID:16346273

  5. Bacterial culture detection and identification in blood agar plates with an optoelectronic nose.

    PubMed

    Lim, Sung H; Mix, Samantha; Anikst, Victoria; Budvytiene, Indre; Eiden, Michael; Churi, Yair; Queralto, Nuria; Berliner, Anders; Martino, Raymond A; Rhodes, Paul A; Banaei, Niaz

    2016-02-01

    Clinical microbiology automation is currently limited by the lack of an in-plate culture identification system. Using an inexpensive, printed, disposable colorimetric sensor array (CSA) responsive to the volatiles emitted into plate headspace by microorganisms during growth, we report here that not only the presence but the species of bacteria growing in plate was identified before colonies are visible. In 1894 trials, 15 pathogenic bacterial species cultured on blood agar were identified with 91.0% sensitivity and 99.4% specificity within 3 hours of detection. The results indicate CSAs integrated into Petri dish lids present a novel paradigm to speciate microorganisms, well-suited to integration into automated plate handling systems.

  6. The Resazurin-Agar Method - a Quick Test to Determine Water Quality

    NASA Astrophysics Data System (ADS)

    Huckfeldt, J.; Westphal, B.; Claußen, L.

    2015-12-01

    Rezasurin has been used as a smart tracer in stream ecosystems to indicate metabolic activity, specifically aerobic respiration by heterotrophic bacteria. Resazurin is a blue compound which is irreversibly reduced to the pink resorufin in the presence of aerobic bacteria. The degree and speed of colour change from blue to pink is a measure of the degree of oxygen consumption and thus an indirect indication of the concentration of aerobic bacteria in a given medium. A high concentration of bacteria in water indicates a bad water quality. In our work a method was developed using resazurin agar plates to find a quick and easy way for testing water quality and comparing concentrations of bacteria in freshwater and seawater samples. The theory was to concentrate bacteria from a defined volume of water sample onto polycarbonate filters (0.2 μm), which are then placed onto the resazurin agar plate. The presence of aerobic bacteria on the filter will reduce the resazurin in the agar and the compound changes its colour. First tests conducted with different dilutions of a pure culture of yoghurt bacteria showed promising results and confirmed the feasibility of the method. In a further assay, we used water samples from different water layers and different temperatures and were also able to observe differences in the concentration of bacteria, depending on these different environmental conditions.The assay was also successfully used with seawater samples, collected from 2 different stations at 3 different depths in the Baltic Sea (salinity=15). The discolouration of the plates showed good correlation with the oxygen concentrations in the water. The resazurin-agar plate method is economical and fast. Several samples could be investigated at the same time without sacrificing the reliability of the results. Thus it is a good pre-screening test for a quantitative evaluation of bacteria in a water sample.

  7. Plating methods, a survey

    NASA Technical Reports Server (NTRS)

    Berkowitz, J. B.; Emerson, N. H.

    1972-01-01

    Results are presented of a comprehensive search of the literature available, much of which has been generated by the research centers of NASA and its contractors, on plating and coating methods and techniques. Methods covered included: (1) electroplating from aqueous solutions; (2) electroplating from nonaqueous solutions; (3) electroplating from fused-salt baths; (4) electroforming; (5) electroless plating, immersion plating, and mirroring; (6) electroplating from gaseous plasmas; and (7) anodized films and conversion coatings.

  8. Trace Amounts of Furan-2-Carboxylic Acids Determine the Quality of Solid Agar Plates for Bacterial Culture

    PubMed Central

    Hara, Shintaro; Isoda, Reika; Tahvanainen, Teemu; Hashidoko, Yasuyuki

    2012-01-01

    Background Many investigators have recognised that a significant proportion of environmental bacteria exist in a viable but non-culturable state on agar plates, and some researchers have also noticed that some of such bacteria clearly recover their growth on matrices other than agar. However, the reason why agar is unsuitable for the growth of some bacteria has not been addressed. Methodology/Principal Findings According to the guide of a bioassay for swarming inhibition, we identified 5-hydroxymethylfuran-2-carboxylic acid (5-HMFA) and furan-2-carboxylic acid (FA) as factors that inhibit bacterial swarming and likely inhibit extracellular polysaccharide production on agar. The furan-2-carboxylic acids 5-HMFA and FA effectively inhibited the swarming and swimming of several environmental bacteria at concentrations of 1.8 and 2.3 µg L−1 (13 and 21 nmol L−1), respectively, which are equivalent to the concentrations of these compounds in 0.3% agar. On Luria-Bertani (LB) plates containing 1.0% agar that had been previously washed with MeOH, a mixture of 5-HMFA and FA in amounts equivalent to their original concentrations in the unwashed agar repressed the swarming of Escherichia coli K12 strain W3110, a representative swarming bacterium. Conclusions/Significance Agar that contains trace amounts of 5-HMFA and FA inhibits the proliferation of some slow-growing or difficult-to-culture bacteria on the plates, but it is useful for single colony isolation due to the ease of identification of swarmable bacteria as the non-swarmed colonies. PMID:22848437

  9. Total Antioxidant Capacity of Serum Determined Using the Potassium Permanganate Agar Method Based on Serum Diffusion in Agar

    PubMed Central

    Zhou, Ying; Zhang, Meijuan; Liu, Hui

    2015-01-01

    Objectives. To develop a new method for determining total antioxidants in serum and to evaluate the total antioxidant capacity of organisms. Design and Methods. Sodium hyposulfite (Na2S2O3) and serum were used to evaluate the linearity and precision of the potassium permanganate agar method. The area of serum diffusion in samples from 30 intensive care unit (ICU) patients compared with 44 healthy subjects was determined by the potassium permanganate agar method. Results. The linearity (R2 in the linear experiment of Na2S2O3 was 0.994; R2 in the linear experiment of serum was 0.987) and precision (coefficient of variation of area of high level serum diffusion within-run, between-run, and between-day and coefficient of variation of area of low serum diffusion within-run, between-run, and between-day were all less than 10%) were acceptable using the potassium permanganate agar method. Total antioxidants of serum between the ICU group and the healthy group were different (p = 0.002, two tailed). Conclusions. Total antioxidants in serum can be determined by the potassium permanganate agar method. The total antioxidant capacity of an organism can be evaluated by the amount of total antioxidants in serum. PMID:26347595

  10. AUTORADIOGRAPHIC ANALYSIS ON AGAR PLATES OF ANTIGENS FROM SUB CELLULAR FRACTIONS OF RAT LIVER SLICES

    PubMed Central

    Morgan, W. S.; Perlmann, P.; Hultin, T.

    1961-01-01

    Slices of rat livers were incubated with 14C amino acids, homogenized, and subjected to differential centrifugation. The microsomes were further extracted with the non-ionic detergent Lubrol W and with EDTA. These extracts and the microsome free "cell sap," freed from the pH 5 precipitable fraction, were subsequently reacted with antisera using agar diffusion techniques. The antisera employed were obtained from rabbits injected with different subcellular fractions of rat liver or with rat serum proteins. When the agar diffusion plates were autoradiographed it was found that some of the precipitates were radioactive while others were not. Control experiments indicated that this labeling was due to the specific incorporation of 14C amino acids into various rat liver antigens during incubation of the slices rather than to a non-specific adsorption of radioactive material to the immunological precipitates. When the slices were incubated with the isotope for up to 30 minutes, the serum proteins which could be extracted from the microsomes with the detergent were strongly labeled, as were a number of additional microsomal antigens of unknown significance. In contrast, the serum proteins present in the cell sap were only weakly labeled. Most of the typical cell sap proteins, both those precipitable and those soluble at pH 5, seemed to remain unlabeled. No consistently reproducible results were obtained with the EDTA extracts of the ribosomal residues remaining after extraction of the microsomes with the detergent. Incubation of the liver slices for longer periods (up to 120 minutes) led to a strong labeling of the serum proteins in the cell sap as well as to the appearance of labeling in additional cell sap proteins. The results are discussed with regard to the subcellular site of synthesis and the metabolism of the different antigens. PMID:13772607

  11. Characterization of multidrug-resistant group B streptococci with reduced penicillin susceptibility forming small non-Beta-hemolytic colonies on sheep blood agar plates.

    PubMed

    Banno, Hirotsugu; Kimura, Kouji; Tanaka, Yosuke; Kitanaka, Hiromitsu; Jin, Wanchun; Wachino, Jun-ichi; Yamada, Keiko; Shibayama, Keigo; Arakawa, Yoshichika

    2014-06-01

    We isolated and characterized three multidrug-resistant clinical isolates of group B streptococci with reduced penicillin susceptibility (PRGBS) that formed small non-beta-hemolytic colonies on sheep blood agar plates but grew well on chocolate agar plates. They can be overlooked in the bacterial identification step, leading to clinical misdiagnosis and treatment failure.

  12. How to optimize the drop plate method for enumerating bacteria.

    PubMed

    Herigstad, B; Hamilton, M; Heersink, J

    2001-03-01

    The drop plate (DP) method can be used to determine the number of viable suspended bacteria in a known beaker volume. The drop plate method has some advantages over the spread plate (SP) method. Less time and effort are required to dispense the drops onto an agar plate than to spread an equivalent total sample volume into the agar. By distributing the sample in drops, colony counting can be done faster and perhaps more accurately. Even though it has been present in the laboratory for many years, the drop plate method has not been standardized. Some technicians use 10-fold dilutions, others use twofold. Some technicians plate a total volume of 0.1 ml, others plate 0.2 ml. The optimal combination of such factors would be useful to know when performing the drop plate method. This investigation was conducted to determine (i) the standard deviation of the bacterial density estimate, (ii) the cost of performing the drop plate procedure, (iii) the optimal drop plate design, and (iv) the advantages of the drop plate method in comparison to the standard spread plate method. The optimal design is the combination of factor settings that achieves the smallest standard deviation for a fixed cost. Computer simulation techniques and regression analysis were used to express the standard deviation as a function of the beaker volume, dilution factor, and volume plated. The standard deviation expression is also applicable to the spread plate method.

  13. Spiral plate method for bacterial determination.

    PubMed

    Gilchrist, J E; Campbell, J E; Donnelly, C B; Peeler, J T; Delaney, J M

    1973-02-01

    A method is described for determining the number of bacteria in a solution by the use of a machine which deposits a known volume of sample on a rotating agar plate in an ever decreasing amount in the form of an Archimedes spiral. After the sample is incubated, different colony densities are apparent on the surface of the plate. A modified counting grid is described which relates area of the plate of volume of sample. By counting an appropriate area of the plate, the number of bacteria in the sample is estimated. This method was compared to the pour plate procedure with the use of pure and mixed cultures in water and milk. The results did not demonstrate a significant difference in variance between duplicates at the alpha = 0.01 level when concentrations of 600 to 12 x 10(5) bacteria per ml were used, but the spiral plate method gave counts that were higher than counts obtained by the pour plate method. The time and materials required for this method are substantially less than those required for the conventional aerobic pour plate procedure.

  14. Use of hydrogen peroxide treatment and crystal violet agar plates for selective recovery of bacteriophages from natural environments

    SciTech Connect

    Asghari, A.; Farrah, S.R.; Bitton, G. )

    1992-04-01

    Hydrogen peroxide inactivated bacteriophages and bacteria at different rates. A concentration of 0.1% hydrogen peroxide reduced the numbers of several bacteria by an average of 94% but caused an average of 25% inactivation in the numbers of bacteriophages tested. Treating natural samples with hydrogen peroxide selectively reduced the indigenous bacterial flora and permitted better visualization of plaques of lawns of Escherichia coli C-3000. In some cases indigenous gram-positive bacteria were relatively resistant to hydrogen peroxide, but their growth could be limited by incorporation of crystal violet into the bottom agar used for plaque assays. The use of hydrogen peroxide treatment and crystal violet-containing plates permitted recovery of more phages from natural samples than did other procedures, such as chloroform pretreatment or the use of selective plating agar such as EC medium.

  15. Solvent-tolerance of fungi located on an interface between an agar plate and an organic solvent.

    PubMed

    Oda, Shinobu; Sugitani, Ayaka; Ohashi, Shinichi

    2014-01-01

    While 6 by 20 of type culture fungi could grow on an interface between organic solvent (log P, 4.12) and agar plate, 13 by 20 of strains could form a large colony after the removal of more toxic solvent, such as styrene (log P, 2.95) and tert-butyl acetate (log P, 1.76) because of viability of spores on the interface.

  16. Rapid Identification of Positive Blood Cultures by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Using Prewarmed Agar Plates

    PubMed Central

    Bhatti, M. M.; Boonlayangoor, S.; Beavis, K. G.

    2014-01-01

    This study describes an inexpensive and straightforward method for identifying bacteria by matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) directly from positive blood cultures using prewarmed agar plates. Different inoculation methods and incubation times were evaluated to determine the optimal conditions. The two methods using pelleted material from positive culture bottles performed best. In particular, the pellet streak method correctly identified 94% of the Gram negatives following 4 h of incubation and 98% of the Gram positives following 6 h of incubation. PMID:25232166

  17. Rapid identification of positive blood cultures by matrix-assisted laser desorption ionization-time of flight mass spectrometry using prewarmed agar plates.

    PubMed

    Bhatti, M M; Boonlayangoor, S; Beavis, K G; Tesic, V

    2014-12-01

    This study describes an inexpensive and straightforward method for identifying bacteria by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) directly from positive blood cultures using prewarmed agar plates. Different inoculation methods and incubation times were evaluated to determine the optimal conditions. The two methods using pelleted material from positive culture bottles performed best. In particular, the pellet streak method correctly identified 94% of the Gram negatives following 4 h of incubation and 98% of the Gram positives following 6 h of incubation.

  18. [Analysis of bactericidal material generated by electrical devices advertising bactericidal ability against bacteria on the agar gel plates].

    PubMed

    Nishimura, Hidekazu

    2012-11-01

    Several Japanese companies sell electrical devices advertised as effective in inactivating viruses and killing bacteria by releasing special materials, e.g., Plasmacluster ions, Nanoe particle and minus ions, into the air. These companies claim that their devices killed bacteria on plates in their own experiments. We tested device effectiveness using the same experiments from the Plasmacluster ioniser SHARP Co., Japan, the Nanoe generator Panasonic Co., Japan, and the Vion KING JIM Co., Japan, to test their advertising claims. Bactericidal ability on agar plate was tested, using Staphylococcus aureus, Pseudomonas aeruginosa, Bacillus cereus, and Enterococcus faecalis as follows: the medium containing a certain amount of each bacterium was put onto an agar plate and smeared. Plates were kept in a closed chamber (inner volume 14.4 m3) or a glove box (inner volume 0.2 m), with one of the devices run for 2 hours. Plates not exposed to any device were used as controls. Each plate was retrieved and put in an incubator to count the number of bacterial colonies formed on the plate. There was no significant difference in the number of colonies on plates exposed to devices compared to control, in the number for all devices, or in all bacteria tested in experiments in the 14.4 m3 chamber. These results strongly suggest that these devices have almost no bactericidal effect, at least in space exceeding this volume. Colony formation was suppressed in the glove box in all devices and in all bacteria tested except P. aeruginosa, although the degree of suppression differed among experiments. The colony formation suppression mechanism was analyzed, and indicated that:colony formation did not change even after the removal of Plasmacluster ions, Nanoe particles, or negative ions from the air, while colony formation was decreased drastically by the removal of ozone from space, which was revealed to be generated inevitably during device operation. These results strongly suggest that the

  19. Light-scattering sensor for real-time identification of Vibrio parahaemolyticus, Vibrio vulnificus and Vibrio cholerae colonies on solid agar plate.

    PubMed

    Huff, Karleigh; Aroonnual, Amornrat; Littlejohn, Amy E Fleishman; Rajwa, Bartek; Bae, Euiwon; Banada, Padmapriya P; Patsekin, Valery; Hirleman, E Daniel; Robinson, J Paul; Richards, Gary P; Bhunia, Arun K

    2012-09-01

    The three most common pathogenic species of Vibrio, Vibrio cholerae, Vibrio parahaemolyticus and Vibrio vulnificus, are of major concerns due to increased incidence of water- and seafood-related outbreaks and illness worldwide. Current methods are lengthy and require biochemical and molecular confirmation. A novel label-free forward light-scattering sensor was developed to detect and identify colonies of these three pathogens in real time in the presence of other vibrios in food or water samples. Vibrio colonies grown on agar plates were illuminated by a 635 nm laser beam and scatter-image signatures were acquired using a CCD (charge-coupled device) camera in an automated BARDOT (BActerial Rapid Detection using Optical light-scattering Technology) system. Although a limited number of Vibrio species was tested, each produced a unique light-scattering signature that is consistent from colony to colony. Subsequently a pattern recognition system analysing the collected light-scatter information provided classification in 1-2 min with an accuracy of 99%. The light-scattering signatures were unaffected by subjecting the bacteria to physiological stressors: osmotic imbalance, acid, heat and recovery from a viable but non-culturable state. Furthermore, employing a standard sample enrichment in alkaline peptone water for 6 h followed by plating on selective thiosulphate citrate bile salts sucrose agar at 30°C for ∼ 12 h, the light-scattering sensor successfully detected V. cholerae, V. parahaemolyticus and V. vulnificus present in oyster or water samples in 18 h even in the presence of other vibrios or other bacteria, indicating the suitability of the sensor as a powerful screening tool for pathogens on agar plates.

  20. Comparison of recovery of airborne microorganisms in a dairy cattle facility using selective agar and thin agar layer resuscitation media.

    PubMed

    Crozier-Dodson, Beth Ann; Fung, Daniel Y C

    2002-09-01

    Thin agar layer (TAL) medium was developed at Kansas State University to improve the resuscitation of injured cells and has been shown to result in higher recovery than is obtained with selective media alone for cold-, heat-, salt-, and acid-injured cells. The experiment presented here was designed to determine the effectiveness of the TAL method for the recovery of possibly injured organisms from air. Eleven agar media were used for the experiment: tryptic soy agar (TSA), MacConkey sorbitol agar (MSA), TAL-MSA, Baird-Parker (BP) agar, TAL-BP agar, modified Oxford (MOX) agar, TAL-MOX agar, xylose lysine sodium desoxycholate (XLD) agar, TAL-XLD agar, Yersinia-selective (CIN) agar, and TAL-CIN agar. The TAL plates were prepared by pipetting 6 ml of selective agar into a BBL Rodac plate (65 by 15 mm). Selective agar was allowed to solidify, and then each plate was overlaid with 6 ml of TSA. Selective agar plates were prepared by pipetting 12 ml of agar into BBL Rodac plates and allowing the agar to solidify. Samples were taken at an indoor cattle facility at five separate locations with a BioScience SAS air-sampling instrument. For each plate, 60 liters of air was sampled. Three replications of the experiment were performed. The TAL method resulted in higher counts of microorganisms on all media tested. In addition, 175 isolates were selected randomly and identified in order to test the selectivity of TAL and the selective media for target organisms. The data obtained in this study show that the TAL resuscitation method is effective and necessary for the recovery of airborne organisms that may be injured.

  1. A combined approach for the enhanced detection and isolation of Bartonella species in dog blood samples: pre-enrichment liquid culture followed by PCR and subculture onto agar plates.

    PubMed

    Duncan, Ashlee W; Maggi, Ricardo G; Breitschwerdt, Edward B

    2007-05-01

    Historically, direct plating, lysis centrifugation, or freeze-thaw approaches have proven to be highly insensitive methods for confirming Bartonella species infection in dogs. A prospective study was designed to compare diagnostic methods for the detection of Bartonella using samples submitted to the Vector-Borne Disease Diagnostic Laboratory at North Carolina State University. Methods included indirect immunofluorescence assay, PCR, direct inoculation of a blood agar plate (trypticase soy agar with 5% rabbit blood), and inoculation into a novel pre-enrichment liquid medium, Bartonella/alpha-Proteobacteria growth medium (BAPGM). Sequential research efforts resulted in the development of a combinational approach consisting of pre-enrichment culture of Bartonella species in BAPGM, sub-inoculation of the liquid culture onto agar plates, followed by DNA amplification using PCR. The multi-faceted approach resulted in substantial improvement in the microbiological detection and isolation of Bartonella when compared to direct inoculation of a blood agar plate. Importantly, this approach facilitated the detection and subsequent isolation of both single and co-infections with two Bartonella species in the blood of naturally infected dogs. The use of a combinational approach of pre-enrichment culture and PCR may assist in the diagnostic confirmation of bartonellosis in dogs and other animals.

  2. Evaluation of heterotrophic plate and chromogenic agar colony counting in water quality laboratories.

    PubMed

    Hallas, Gary; Monis, Paul

    2015-01-01

    The enumeration of bacteria using plate-based counts is a core technique used by food and water microbiology testing laboratories. However, manual counting of bacterial colonies is both time and labour intensive, can vary between operators and also requires manual entry of results into laboratory information management systems, which can be a source of data entry error. An alternative is to use automated digital colony counters, but there is a lack of peer-reviewed validation data to allow incorporation into standards. We compared the performance of digital counting technology (ProtoCOL3) against manual counting using criteria defined in internationally recognized standard methods. Digital colony counting provided a robust, standardized system suitable for adoption in a commercial testing environment. The digital technology has several advantages:•Improved measurement of uncertainty by using a standard and consistent counting methodology with less operator error.•Efficiency for labour and time (reduced cost).•Elimination of manual entry of data onto LIMS.•Faster result reporting to customers.

  3. Evaluation of heterotrophic plate and chromogenic agar colony counting in water quality laboratories.

    PubMed

    Hallas, Gary; Monis, Paul

    2015-01-01

    The enumeration of bacteria using plate-based counts is a core technique used by food and water microbiology testing laboratories. However, manual counting of bacterial colonies is both time and labour intensive, can vary between operators and also requires manual entry of results into laboratory information management systems, which can be a source of data entry error. An alternative is to use automated digital colony counters, but there is a lack of peer-reviewed validation data to allow incorporation into standards. We compared the performance of digital counting technology (ProtoCOL3) against manual counting using criteria defined in internationally recognized standard methods. Digital colony counting provided a robust, standardized system suitable for adoption in a commercial testing environment. The digital technology has several advantages:•Improved measurement of uncertainty by using a standard and consistent counting methodology with less operator error.•Efficiency for labour and time (reduced cost).•Elimination of manual entry of data onto LIMS.•Faster result reporting to customers. PMID:26649275

  4. Development of a Colony Lift Immunoassay To Facilitate Rapid Detection and Quantification of Escherichia coli O157:H7 from Agar Plates and Filter Monitor Membranes

    PubMed Central

    Ingram, David T.; Lamichhane, Chinta M.; Rollins, David M.; Carr, Lewis E.; Mallinson, Edward T.; Joseph, Sam W.

    1998-01-01

    E. coli O157:H7 is a food-borne adulterant that can cause hemorrhagic ulcerative colitis and hemolytic uremic syndrome. Faced with an increasing risk of foods contaminated with E. coli O157:H7, food safety officials are seeking improved methods to detect and isolate E. coli O157:H7 in hazard analysis and critical control point systems in meat- and poultry-processing plants. A colony lift immunoassay was developed to facilitate the positive identification and quantification of E. coli O157:H7 by incorporating a simple colony lift enzyme-linked immunosorbent assay with filter monitors and traditional culture methods. Polyvinylidene difluoride (PVDF) membranes (Millipore, Bedford, Mass.) were prewet with methanol and were used to make replicates of every bacterial colony on agar plates or filter monitor membranes that were then reincubated for 15 to 18 h at 36 ± 1°C, during which the colonies not only remained viable but were reestablished. The membranes were dried, blocked with blocking buffer (Kirkegaard and Perry Laboratories [KPL], Gaithersburg, Md.), and exposed for 7 min to an affinity-purified horseradish peroxidase-labeled goat anti-E. coli O157 antibody (KPL). The membranes were washed, exposed to a 3,3′,5,5′-tetramethylbenzidine membrane substrate (TMB; KPL) or aminoethyl carbazole (AEC; Sigma Chemical Co., St. Louis, Mo.), rinsed in deionized water, and air dried. Colonies of E. coli O157:H7 were identified by either a blue (via TMB) or a red (via AEC) color reaction. The colored spots on the PVDF lift membrane were then matched to their respective parent colonies on the agar plates or filter monitor membranes. The colony lift immunoassay was tested with a wide range of genera in the family Enterobacteriaceae as well as different serotypes within the E. coli genus. The colony lift immunoassay provided a simple, rapid, and accurate method for confirming the presence of E. coli O157:H7 colonies isolated on filter monitors or spread plates by traditional

  5. Correlation between Agar Plate Screening and Solid-State Fermentation for the Prediction of Cellulase Production by Trichoderma Strains.

    PubMed

    Florencio, Camila; Couri, Sonia; Farinas, Cristiane Sanchez

    2012-01-01

    The viability of converting biomass into biofuels and chemicals still requires further development towards the reduction of the enzyme production costs. Thus, there is a growing demand for the development of efficient procedures for selection of cellulase-producing microorganisms. This work correlates qualitative screening using agar plate assays with quantitative measurements of cellulase production during cultivation under solid-state fermentation (SSF). The initial screening step consisted of observation of the growth of 78 preselected strains of the genus Trichoderma on plates, using microcrystalline cellulose as carbon source. The 49 strains that were able to grow on this substrate were then subjected to a second screening step using the Congo red test. From this test it was possible to select 10 strains that presented the highest enzymatic indices (EI), with values ranging from 1.51 to 1.90. SSF cultivations using sugarcane bagasse and wheat bran as substrates were performed using selected strains. The CG 104NH strain presented the highest EGase activity (25.93 UI·g(-1)). The EI results obtained in the screening procedure using plates were compared with cellulase production under SSF. A correlation coefficient (R(2)) of 0.977 was obtained between the Congo red test and SSF, demonstrating that the two methodologies were in good agreement. PMID:23227312

  6. Evaluation of an immunochromatographic assay for direct identification of thermostable direct hemolysin-producing Vibrio parahaemolyticus colonies on selective agar plates.

    PubMed

    Kawatsu, Kentaro; Sakata, Junko; Yonekita, Taro; Kumeda, Yuko

    2015-12-01

    We evaluated the utility of an immunochromatographic assay (NH IC TDH) in identifying thermostable direct hemolysin (TDH)-producing Vibrio parahaemolyticus colonies on selective agar plates. The sensitivity of the NH IC TDH assay was 100% (189 samples) and its specificity was 100% (41 samples) compared with the presence of tdh.

  7. Efficacy of the thin agar layer method for the recovery of stressed Cronobacter spp. (Enterobacter sakazakii).

    PubMed

    Osaili, Tareq M; Al-Nabulsi, Anas A; Shaker, Reyad R; Al-Holy, Murad M; Al-Haddaq, Mohammed S; Olaimat, Amin N; Ayyash, Mutamed M; Al Ta'ani, Mahmoud K; Forsythe, Stephen J

    2010-10-01

    Cronobacter spp. (Enterobacter sakazakii) are emerging opportunistic pathogens for all age groups, and are of particular concern when it comes to infants. Prior to contaminating food, the organism may be exposed to a variety of stresses, leading to a generation of sublethally injured cells that may not be detected by selective media unless a protracted recovery period is included in the isolation procedure. This study evaluated the efficacy of the thin agar layer (TAL) method for the recovery of Cronobacter cells that had been exposed to various stress conditions. Five strains of C. sakazakii and C. muytjensii were exposed to starvation, heat, cold, acid, alkaline, chlorine, or ethanol, with or without further exposure to desiccation stress. The recovery of the stressed cells was determined on tryptone soy agar (TSA; nonselective control medium), violet red bile glucose agar (VRBGA; selective agar), Druggan-Forsythe-Iversen (DFI; selective agar), and TAL media (viz., VRBGA overlaid with TSA, and DFI overlaid with TSA). Regardless of stress type, there were no significant differences among the recoveries of stressed desiccated Cronobacter spp. cultures on TSA, DFI+TSA, and VRBGA+TSA, but there was significantly less recovery on VRBGA. The recovery of prestressed desiccated Cronobacter spp. on DFI+TSA was similar to that on TSA, whereas the recovery on VRBGA+TSA was lower. DFI+TSA performed better than VRBGA+TSA did in differentiating Cronobacter spp. within mixed bacterial cultures. The results of this study suggest the use of the TAL method DFI+TSA as an improved method for the direct recovery of stressed Cronobacter spp.

  8. Colony morphotype on Sabouraud-triphenyltetrazolium agar: a simple and inexpensive method for Candida subspecies discrimination.

    PubMed Central

    Quindós, G; Fernández-Rodríguez, M; Burgos, A; Tellaetxe, M; Cisterna, R; Pontón, J

    1992-01-01

    A new method of Candida subspecies discrimination on Sabouraud-triphenyltetrazolium agar is reported. Five hundred sixty-two strains of Candida and Torulopsis glabrata, previously identified by conventional mycological methods, were studied. Each strain received a three-letter code and a number based on its colonial morphology. Sixteen morphotypes were found for Candida albicans, 6 were found for Candida parapsilosis, 4 were found for both Candida guilliermondii and Candida krusei, and 12 were found for Candida tropicalis. None of the 56 T. glabrata strains studied grew on this agar. A reproducibility of 95% was found for C. albicans. The simplicity and low cost could make this method useful for typing Candida spp. Images PMID:1400981

  9. Modification of the Congo red agar method to detect biofilm production by Staphylococcus epidermidis.

    PubMed

    Kaiser, Thaís Dias Lemos; Pereira, Eliezer Menezes; Dos Santos, Kátia Regina Netto; Maciel, Ethel Leonor Noia; Schuenck, Ricardo Pinto; Nunes, Ana Paula Ferreira

    2013-03-01

    Staphylococcus epidermidis in immunocompromised patients can cause bacteremia related to the use of catheter due to biofilm production. There are different phenotypic methods to detect biofilm formation. One method is based on culture in brain heart infusion agar (BHIA) containing sucrose and red Congo dye (original Congo red agar). Our group created a new CRA formula and we have confirmed its capacity to detect biofilm production in 210 S. epidermidis strains, including 76 (36.2%) icaAB gene-positive strains. Other parameters were also evaluated. The new CRA formula that gave the best results was BHIA with sucrose (5%), Congo red (0.08%), NaCl (1.5%), glucose (2%), and vancomycin (0.5 mg/mL) (vancomycin-modified CRA-CRAmod). The CRAmod plus vancomycin may be a promising tool and can help to determine the real participation of S. epidermidis in the infectious process.

  10. Modification of the Congo red agar method to detect biofilm production by Staphylococcus epidermidis.

    PubMed

    Kaiser, Thaís Dias Lemos; Pereira, Eliezer Menezes; Dos Santos, Kátia Regina Netto; Maciel, Ethel Leonor Noia; Schuenck, Ricardo Pinto; Nunes, Ana Paula Ferreira

    2013-03-01

    Staphylococcus epidermidis in immunocompromised patients can cause bacteremia related to the use of catheter due to biofilm production. There are different phenotypic methods to detect biofilm formation. One method is based on culture in brain heart infusion agar (BHIA) containing sucrose and red Congo dye (original Congo red agar). Our group created a new CRA formula and we have confirmed its capacity to detect biofilm production in 210 S. epidermidis strains, including 76 (36.2%) icaAB gene-positive strains. Other parameters were also evaluated. The new CRA formula that gave the best results was BHIA with sucrose (5%), Congo red (0.08%), NaCl (1.5%), glucose (2%), and vancomycin (0.5 mg/mL) (vancomycin-modified CRA-CRAmod). The CRAmod plus vancomycin may be a promising tool and can help to determine the real participation of S. epidermidis in the infectious process. PMID:23313084

  11. A method of test substance removal in agar colony assays using glass capillaries.

    PubMed

    Kastner, M; Maurer, H R

    1984-07-01

    A technique has been developed to remove test substances, after defined incubation periods, from clonogenic in vitro assays using agar-containing glass capillaries. Following removal from the capillaries, the entire agar gels were washed in petri dishes and redrawn into new capillaries. Using 8 radioactive biochemicals of molecular masses ranging from 150 to 1300 dalton the kinetics of diffusion between 1 and 20 min were determined. Using a wash solution-to-assay volume ratio of 20:1, a single washing for 10 min yielded between 90% and 99% removal by diffusion of test substances. By incorporating myelopoietic stem cells it was demonstrated that the cells to be assayed can be quantitatively transferred, without loss or stress, out of and back into capillaries. Thus the reversibility of test substance action can examined under defined conditions avoiding technical problems of previous methods.

  12. Optimisation of a direct plating method for the detection and enumeration of Alicyclobacillus acidoterrestris spores.

    PubMed

    Henczka, Marek; Djas, Małgorzata; Filipek, Katarzyna

    2013-01-01

    A direct plating method for the detection and enumeration of Alicyclobacillus acidoterrestris spores has been optimised. The results of the application of four types of growth media (BAT agar, YSG agar, K agar and SK agar) regarding the recovery and enumeration of A. acidoterrestris spores were compared. The influence of the type of applied growth medium, heat shock conditions, incubation temperature, incubation time, plating technique and the presence of apple juice in the sample on the accuracy of the detection and enumeration of A. acidoterrestris spores was investigated. Among the investigated media, YSG agar was the most sensitive medium, and its application resulted in the highest recovery of A. acidoterrestris spores, while K agar and BAT agar were the least suitable media. The effect of the heat shock time on the recovery of spores was negligible. When there was a low concentration of spores in a sample, the membrane filtration method was superior to the spread plating method. The obtained results show that heat shock carried out at 80°C for 10 min and plating samples in combination with membrane filtration on YSG agar, followed by incubation at 46°C for 3 days provided the optimal conditions for the detection and enumeration of A. acidoterrestris spores. Application of the presented method allows highly efficient, fast and sensitive identification and enumeration of A. acidoterrestris spores in food products. This methodology will be useful for the fruit juice industry for identifying products contaminated with A. acidoterrestris spores, and its practical application may prevent economic losses for manufacturers.

  13. Identification of Brucella by MALDI-TOF Mass Spectrometry. Fast and Reliable Identification from Agar Plates and Blood Cultures

    PubMed Central

    Ferreira, Laura; Vega Castaño, Silvia; Sánchez-Juanes, Fernando; González-Cabrero, Sandra; Menegotto, Fabiola; Orduña-Domingo, Antonio

    2010-01-01

    Background MALDI-TOF mass spectrometry (MS) is a reliable method for bacteria identification. Some databases used for this purpose lack reference profiles for Brucella species, which is still an important pathogen in wide areas around the world. We report the creation of profiles for MALDI-TOF Biotyper 2.0 database (Bruker Daltonics, Germany) and their usefulness for identifying brucellae from culture plates and blood cultures. Methodology/Principal Findings We created MALDI Biotyper 2.0 profiles for type strains belonging to B. melitensis biotypes 1, 2 and 3; B. abortus biotypes 1, 2, 5 and 9; B. suis, B. canis, B ceti and B. pinnipedialis. Then, 131 clinical isolates grown on plate cultures were used in triplicate to check identification. Identification at genus level was always correct, although in most cases the three replicates reported different identification at species level. Simulated blood cultures were performed with type strains belonging to the main human pathogenic species (B. melitensis, B. abortus, B. suis and B. canis), and studied by MALDI-TOF MS in triplicate. Identification at genus level was always correct. Conclusions/Significance MALDI-TOF MS is reliable for Brucella identification to the genus level from culture plates and directly from blood culture bottles. PMID:21151913

  14. Rectal screening for Klebsiella pneumoniae carbapenemases: comparison of real-time PCR and culture using two selective screening agar plates.

    PubMed

    Singh, Kamaljit; Mangold, Kathy A; Wyant, Kody; Schora, Donna M; Voss, Barbara; Kaul, Karen L; Hayden, Mary K; Chundi, Vishnu; Peterson, Lance R

    2012-08-01

    Klebsiella pneumoniae carbapenemases (KPCs) have recently been described in Chicago, IL, especially among residents of long-term acute care hospitals (LTACHs). These patients are frequently transferred to local Chicago hospitals for higher acuity of medical care, and rapid detection and isolation of KPC-colonized LTACH residents may interrupt the introduction of KPCs into acute care hospitals. We evaluated the performance of a real-time PCR for bla(KPC) from enrichment broth versus direct plating of rectal surveillance swabs on two selective culture media, CHROMagar extended-spectrum-β-lactamase (ESBL) and vancomycin, amphotericin B, ceftazidime, and clindamycin (VACC) plates. Rectal surveillance swabs were collected as part of a point prevalence study of KPC carriage rates among 95 residents of two Chicago area LTACHs. Discrepant results between PCR and culture were resolved by subculturing the enrichment broth. Overall, 66 of 95 patients (69.5%) were colonized with KPCs, using the cumulative results of culture as a reference standard. Real-time PCR from enrichment broth was positive in 64 of 66 (97%) colonized patients, including nine surveillance swabs that were missed by both selective culture media. PCR demonstrated higher sensitivity, 97.0%, than culture using either CHROMagar or VACC plates (both with sensitivity of 77.3%). In addition, turnaround time was significantly shorter for the PCR-based method than for culture, with a mean of 24 h versus 64 to 72 h for CHROMagar and VACC plates (P < 0.0001). Overall, PCR for bla(KPC) represents the best screening test for KPCs with significantly higher sensitivity and with less hands-on time, resulting in a shorter time to results.

  15. Aerobically incubated medium for decarboxylase testing of Enterobacteriaceae by replica-plating methods.

    PubMed

    Maccani, J E

    1979-12-01

    An aerobically incubated, agar-based medium was developed for amino acid decarboxylase testing of Enterobacteriaceae family members by replica-plating methods. Results with the new medium agreed 97 to 99% with the reference broth method of Moeller, and no false-positive reactions were encountered.

  16. AgarTrap: a simplified Agrobacterium-mediated transformation method for sporelings of the liverwort Marchantia polymorpha L.

    PubMed

    Tsuboyama, Shoko; Kodama, Yutaka

    2014-01-01

    The liverwort Marchantia polymorpha L. is being developed as an emerging model plant, and several transformation techniques were recently reported. Examples are biolistic- and Agrobacterium-mediated transformation methods. Here, we report a simplified method for Agrobacterium-mediated transformation of sporelings, and it is termed Agar-utilized Transformation with Pouring Solutions (AgarTrap). The procedure of the AgarTrap was carried out by simply exchanging appropriate solutions in a Petri dish, and completed within a week, successfully yielding sufficient numbers of independent transformants for molecular analysis (e.g. characterization of gene/protein function) in a single experiment. The AgarTrap method will promote future molecular biological study in M. polymorpha.

  17. Evaluation of agar dilution and broth microdilution methods to determine the disinfectant susceptibility.

    PubMed

    Wu, Guoyan; Yang, Qianru; Long, Mei; Guo, Lijuan; Li, Bei; Meng, Yue; Zhang, Anyun; Wang, Hongning; Liu, Shuliang; Zou, Likou

    2015-11-01

    A variety of disinfectants have been widely used in veterinary hygiene, food industries and environments, which could induce the development of bacterial resistance to disinfectants. The methods used to investigate antimicrobial effects of disinfectant vary considerably among studies, making comparisons difficult. In this study, agar dilution and broth microdilution methods were used to compare the antimicrobial activities of four quaternary ammonium compounds (QACs) against foodborne and zoonotic pathogens. The potential relationship between the presence of QACs resistance genes and phenotypic resistance to QACs was also investigated. Our results indicated that the minimum inhibitory concentrations (MICs) determined by two methods might be different depended upon different QACs and bacteria applied. Regardless of the testing methods, Klebsiella pneumoniae was more tolerant among Gram-negative strains to four QACs, followed by Salmonella and Escherichia coli. The agreement between MICs obtained by the two methods was good, for benzalkonium chloride (78.15%), didecyldimethylammonium chloride (DDAC) (82.35%), cetylpyridinium chloride (CTPC) (97.48%) and cetyltrimethylammonium bromide (CTAB) (99.16%), respectively. Among all Gram-negative bacteria, 94.55% (n=52) of qacEΔ1-positive strains showed higher MICs (512 mg l(-1)) to CTAB. The qacEΔ1 gene was highly associated (P<0.05) with the high MICs of QACs (⩾512 mg l(-1)). In addition, DDAC remained as the most effective disinfectant against both Gram-positive and Gram-negative bacteria. This is the first study that compared the agar dilution and broth microdilution methods to assess the antimicrobial activity of QACs. The study demonstrated the need to standardize method that would be used in evaluating QACs antimicrobial properties in the future.

  18. Wood and humus decay strategies by white-rot basidiomycetes correlate with two different dye decolorization and enzyme secretion patterns on agar plates.

    PubMed

    Barrasa, José M; Blanco, María N; Esteve-Raventós, Fernando; Altés, Alberto; Checa, Julia; Martínez, Angel T; Ruiz-Dueñas, Francisco J

    2014-11-01

    During several forays for ligninolytic fungi in different Spanish native forests, 35 white-rot basidiomycetes growing on dead wood (16 species from 12 genera) and leaf litter (19 species from 10 genera) were selected for their ability to decolorize two recalcitrant aromatic dyes (Reactive Blue 38 and Reactive Black 5) added to malt extract agar medium. In this study, two dye decolorization patterns were observed and correlated with two ecophysiological groups (wood and humus white-rot basidiomycetes) and three taxonomical groups (orders Polyporales, Hymenochaetales and Agaricales). Depending on the above groups, different decolorization zones were observed on the dye-containing plates, being restricted to the colony area or extending to the surrounding medium, which suggested two different decay strategies. These two strategies were related to the ability to secrete peroxidases and laccases inside (white-rot wood Polyporales, Hymenochaetales and Agaricales) and outside (white-rot humus Agaricales) of the fungal colony, as revealed by enzymatic tests performed directly on the agar plates. Similar oxidoreductases production patterns were observed when fungi were grown in the absence of dyes, although the set of enzyme released was different. All these results suggest that the decolorization patterns observed could be related with the existence of two decay strategies developed by white-rot basidiomycetes adapted to wood and leaf litter decay in the field.

  19. Consecutive plate acoustic suppressor apparatus and methods

    NASA Technical Reports Server (NTRS)

    Doychak, Joseph (Inventor); Parrott, Tony (Inventor)

    1992-01-01

    An apparatus and method for suppressing acoustic noise utilizes consecutive plates, closely spaced to each other so as to exploit dissipation associated with sound propagation in narrow channels to optimize the acoustic resistance at a liner surface. The closely spaced plates can be utilized as high temperature structural materials for jet engines by constructing the plates from composite materials. Geometries of the plates, such as plate depth, shape, thickness, inter-plate spacing, arrangement, etc., can be selected to achieve bulk material-like behavior.

  20. Consecutive Plate Acoustic Suppressor Apparatus and Methods

    NASA Technical Reports Server (NTRS)

    Doychak, Joseph (Inventor); Parrott, Tony L. (Inventor)

    1993-01-01

    An apparatus and method for suppressing acoustic noise utilizes consecutive plates, closely spaced to each other so as to exploit dissipation associated with sound propagation in narrow channels to optimize the acoustic resistance at a liner surface. The closely spaced plates can be utilized as high temperature structural materials for jet engines by constructing the plates from composite materials. Geometries of the plates, such as plate depth, shape, thickness, inter-plate spacing, arrangement, etc., can be selected to achieve bulk material-like behavior.

  1. Gene escape model: Transfer of heavy metal resistance genes from Escherichia coli to Alcaligenes eutrophus on agar plates and in soil samples

    SciTech Connect

    Top, E. Studiecentrum voor Kernenergie, Mol ); Mergeay, M.; Springael, D. ); Verstraete, W. )

    1990-08-01

    Conjugal transfer from Escherichia coli to Alcaligenes eutrophus of the A. eutrophus genes coding for plasmid-borne resistance to cadmium, cobalt, and zinc (czc genes) was investigated on agar plates and in soil samples. This czc fragment is not expressed in the donor strain, E. coli, but it is expressed in the recipient strain, A. eutrophus. Hence, expression of heavy metal resistance by cells plated on a medium containing heavy metals represents escape of the czc genes. The two plasmids into which this DNA fragment has been cloned previously and which were used in these experiments are the nonconjugative, mobilizable plasmid pDN705 and the nonconjugative, nonmobilizable plasmid pMOL149. The results demonstrate that even genes incorporated into nonmobilizable plasmids can be exchanged between two different genera and that the presence of broad-host-range plasmids in putative recipients among soil bacteria could increase the risk of gene dissemination in case of release of genetically engineered microorganisms. The results also reveal that in certain soils, environmental conditions and particularly nutrient levels are conducive to gene transfer.

  2. Comparison of the antibacterial activity of chelating agents using the agar diffusion method

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The agar diffusion assay was used to examine antibacterial activity of 2 metal chelators. Concentrations of 0 to 40 mM of ethylenediaminetetraacetic acid (EDTA) and ethylenediamine-N,N’-disuccinic acid (EDDS) were prepared in 1.0 M potassium hydroxide (KOH). The pH of the solutions was adjusted to 1...

  3. In vitro antifungal susceptibility testing of Scopulariopsis brevicaulis strains using agar diffusion method.

    PubMed

    Skóra, Magdalena; Macura, Anna B

    2011-01-01

    The genus Scopulariopsis is a common soil saprotroph and has been isolated from air, organic waste and also from plant, animal and human tissues. Scopulariopsis has mainly been associated in humans with superficial mycoses, but it has also been described as the cause of subcutaneous and invasive infections. The most common aetiological agent of infections in humans is Scopulariopsis brevicaulis. This species has been reported to be resistant in vitro to broad-spectrum antifungal agents available today. The aim of the study was to establish in vitro antifungal susceptibility of 35 S. brevicaulis strains against amphotericin B (AMB), flucytosine (FC), caspofungin (CAS), terbinafine (TER), ciclopirox (CIC), voriconazole (VOR), clotrimazole (CTR), miconazole (MCZ), econazole (ECO), ketoconazole (KET), itraconazole (ITR), and fluconazole (FLU). Antifungal susceptibility tests were evaluated by an agar diffusion method (Neo-Sensitabs, Rosco, Denmark). AMB, FC, CAS, ITR and FLU showed no antifungal activity against S. brevicaulis. TER, CIC, CTR, KET, VOR, ECO, and MCZ revealed inhibitory activity for S. brevicaulis, but it varied for each of the drugs. The best antifungal effect was observed for TER and CIC. All isolates had large inhibition zones for TER and CIC. CTR was also inhibitory for all tested S. brevicaulis isolates, but the diameters of inhibition zones were smaller than for TER and CIC. Nearly 89% isolates showed inhibition zones for KET and the mean diameter of the inhibition zone was comparable to CTR. The least antifungal activity exhibited VQR, ECO and MCZ. Because of the multiresistance of S. brevicaulis, infections due to this species may not respond to particular antifungal treatment and other therapeutic approaches should be considered, e.g., combined therapy and/or surgery. PMID:21682097

  4. In vitro antifungal susceptibility testing of Scopulariopsis brevicaulis strains using agar diffusion method.

    PubMed

    Skóra, Magdalena; Macura, Anna B

    2011-01-01

    The genus Scopulariopsis is a common soil saprotroph and has been isolated from air, organic waste and also from plant, animal and human tissues. Scopulariopsis has mainly been associated in humans with superficial mycoses, but it has also been described as the cause of subcutaneous and invasive infections. The most common aetiological agent of infections in humans is Scopulariopsis brevicaulis. This species has been reported to be resistant in vitro to broad-spectrum antifungal agents available today. The aim of the study was to establish in vitro antifungal susceptibility of 35 S. brevicaulis strains against amphotericin B (AMB), flucytosine (FC), caspofungin (CAS), terbinafine (TER), ciclopirox (CIC), voriconazole (VOR), clotrimazole (CTR), miconazole (MCZ), econazole (ECO), ketoconazole (KET), itraconazole (ITR), and fluconazole (FLU). Antifungal susceptibility tests were evaluated by an agar diffusion method (Neo-Sensitabs, Rosco, Denmark). AMB, FC, CAS, ITR and FLU showed no antifungal activity against S. brevicaulis. TER, CIC, CTR, KET, VOR, ECO, and MCZ revealed inhibitory activity for S. brevicaulis, but it varied for each of the drugs. The best antifungal effect was observed for TER and CIC. All isolates had large inhibition zones for TER and CIC. CTR was also inhibitory for all tested S. brevicaulis isolates, but the diameters of inhibition zones were smaller than for TER and CIC. Nearly 89% isolates showed inhibition zones for KET and the mean diameter of the inhibition zone was comparable to CTR. The least antifungal activity exhibited VQR, ECO and MCZ. Because of the multiresistance of S. brevicaulis, infections due to this species may not respond to particular antifungal treatment and other therapeutic approaches should be considered, e.g., combined therapy and/or surgery.

  5. Method for plating with metal oxides

    DOEpatents

    Silver, G.L.; Martin, F.S.

    1994-08-23

    A method is disclosed of plating hydrous metal oxides on at least one substrate, which method is indifferent to the electrochemical properties of the substrate, and comprises reacting metallic ions in aqueous solution with an appropriate oxidizing agent such as sodium hypochlorite or calcium sulfite with oxygen under suitable conditions of pH and concentration such that oxidation and precipitation of metal oxide are sufficiently slow to allow satisfactory plating of metal oxide on the substrate. 1 fig.

  6. Method for plating with metal oxides

    SciTech Connect

    Silver, Gary L.; Martin, Frank S.

    1994-08-23

    A method of plating hydrous metal oxides on at least one substrate, which method is indifferent to the electrochemical properties of the substrate, and comprises reacting metallic ions in aqueous solution with an appropriate oxidizing agent such as sodium hypochlorite or calcium sulfite with oxygen under suitable conditions of pH and concentration such that oxidation and precipitation of metal oxide are sufficiently slow to allow satisfactory plating of metal oxide on the substrate.

  7. Improved method of screening for aflatoxin with a coconut agar medium.

    PubMed

    Davis, N D; Iyer, S K; Diener, U L

    1987-07-01

    Nine isolates of Aspergillus flavus and Aspergillus parasiticus were screened for aflatoxin production on a coconut extract agar medium. Aflatoxin-producing colonies were detected under long-wave UV light (365 nm) by blue fluorescence on the reverse side after 2 to 5 days of growth. Aflatoxin production was verified by chemical analysis. Several types of shredded coconut available in the United States were tested and found to be satisfactory. No additives were required. Various parameters affecting the test were investigated.

  8. Comparison of E-test with agar dilution methods in testing susceptibility of N. gonorrhoeae to azithromycin.

    PubMed

    Yasin, R M; Suan, K A; Meng, C Y

    1997-05-01

    A single dose of a new antibiotic, azithromycin, has been shown to be effective in the treatment of uncomplicated Neisseria gonorrhoeae. A clinical study was conducted to assess the in vitro susceptibility of N gonorrhoeae to azithromycin and compare the reliability of results obtained using the new E-test methodology for determination of the minimum inhibitory concentration (MIC) of antibiotic with those obtained through the standard agar dilution method. 135 clinical isolates of N gonorrhoeae were obtained from patients attending hospital-based sexually transmitted disease clinics in five geographic locations in Malaysia. 76 of the isolates were penicillinase-producing N gonorrhoeae and 69 were high-level tetracycline-resistant N gonorrhoeae. All isolates were susceptible to azithromycin based on the susceptible MIC breakpoint of 2.0 mcg/ml. The MICs ranged from 0.0078-0.25 mcg/ml by agar dilution method and from 0.016-0.50 mcg/ml by E-test. Agreement between these two methods was 97.8%. The single-dose regime and good antigonococcal and antichlamydial activity of azithromycin make this antibiotic a suitable treatment choice. Moreover, the findings of this study suggest that the simpler, faster E-test is as reliable as the agar dilution method. Given the tendency of the antimicrobial susceptibility pattern of N gonorrhoeae to change rapidly, it is important to monitor MICs to detect the emergence of resistance.

  9. Evaluation of PCR-based screening for vancomycin-resistant enterococci compared with a chromogenic agar-based culture method.

    PubMed

    Seo, Ja Young; Kim, Pyung-Whan; Lee, Jang-Ho; Song, Jae-Hoon; Peck, Kyong-Ran; Chung, Doo-Ryeon; Kang, Cheol-In; Ki, Chang-Seok; Lee, Nam Yong

    2011-07-01

    Rapid detection of vancomycin-resistant enterococci (VRE) infection is very important for control and prevention of nosocomial spread of these bacteria. A multiplex PCR method for rapid screening of VRE has recently been developed. We performed a prospective study of VRE screening tests to compare the performance of PCR to that of a chromogenic agar-based culture method. From January to December 2009, a total of 8815 rectal swab specimens were tested simultaneously for VRE by VRE selective culture and by PCR. The specimens were inoculated onto ChromID VRE agar containing 8 µg vancomycin ml⁻¹ and examined after 24 and 48 h of incubation. Identification and antibiotic susceptibility tests were performed using the automated VITEK-2 system and a supplementary E-test and disk diffusion test. Detection of the vanA and vanB genes was performed with the Seeplex VRE detection kit. Specimens were inoculated in enterococcosel broth for 16-24 h before PCR for enrichment of VRE. VRE were isolated from 741 of the 8815 specimens by chromogenic agar-based culture (8.4 %). vanA and vanB genotypes were detected in 758 (8.6 %) and 3 (0.03 %) specimens, respectively, by multiplex PCR. Sensitivity, specificity, positive predictive value and negative predictive value of PCR for detection of VRE were 98.2 %, 99.6 %, 95.7 %, and 99.8 %. No VRE were isolated from vanB-positive specimens. The overall performance of PCR is comparable to that of a chromogenic agar-based culture method for screening of VRE, so PCR could be an alternative or supportive method for effective control of nosocomial VRE infection.

  10. Agar block smear preparation: a novel method of slide preparation for preservation of native fungal structures for microscopic examination and long-term storage.

    PubMed

    Woo, Patrick C Y; Ngan, Antonio H Y; Chui, Hon-Kit; Lau, Susanna K P; Yuen, Kwok-Yung

    2010-09-01

    We describe a novel method of fungal slide preparation named "agar block smear preparation." A total of 510 agar block smears of 25 fungal strains obtained from culture collections, 90 QC fungal strains, and 82 clinical fungal strains from our clinical microbiology laboratory, which included a total of 137 species of yeasts, molds, and thermal dimorphic fungi, were prepared and examined. In contrast to adhesive tape preparation, agar block smears preserved the native fungal structures, such as intact conidiophores of Aspergillus species and arrangements of conidia in Scopulariopsis brevicaulis. Furthermore, agar block smears allowed examination of fungal structures embedded in the agar, such as the ascomata with ascomal hairs in Chaetomium funicola; pycnidium of Phoma glomerata; the intercalary ovoidal chlamydospores arranged in chains of Fusarium dimerum; and the lateral, spherical chlamydospores arranged in pairs of Fusarium solani. After 1 year of storage, morphological integrity was found to have been maintained in 459 (90%) of the 510 agar block smears. After 3 years of storage, morphological integrity was found to have been maintained in 72 (71%) of the 102 smears prepared in 2006. Agar block smear preparation preserves the native fungal structures and allows long-term storage and examination of fungal structures embedded in the agar, hence overcoming the major drawbacks of adhesive tape preparation. The major roles of agar block smear should be diagnosis for difficult cases, accurate identification of fungal species for clinical management of patients and epidemiological studies, and long-term storage for transportation of slides and education purposes.

  11. Temperature-independent pectin gel method for aerobic plate count in dairy and nondairy food products: collaborative study.

    PubMed

    Roth, J N

    1988-01-01

    Ten laboratories participated in a collaborative study to compare the pectin-based plate count (PC) Redigel method with the aerobic plate count and standard plate count agar-based standard methods for the estimation of total bacterial counts in 9 different nondairy food and dairy food products. The foods were cream, homogenized milk, raw milk, cheese, raw chicken, raw oysters, frozen broccoli, flour, and spices. Each laboratory analyzed 6 samples (3 sample pairs) of each food group. Counts obtained by the pectin-based plate count and agar-based plate count methods differed significantly (P less than 0.05) only for homogenized milk, where the pectin gel method resulted in higher counts. The actual counts were higher in the pectin gel method in 8 of the 9 food groups. The log means for pectin gel and agar-based media, respectively, for the 9 food groups were: cream 8.106 and 7.844; homogenized milk 8.642 and 8.231; raw milk 8.711 and 8.423; chicken 7.654 and 7.645; oysters 7.201 and 7.180; broccoli 7.102 and 6.798; cheese 8.045 and 8.055; flour 4.112 and 3.988; spice 5.379 and 5.314. The repeatability standard deviations favored the pectin gel method in 6 of the 9 foods tested. The reproducibility standard deviations favored the pectin gel method in 7 of the 9 foods tested. These results strongly support the suitability of the pectin gel method as an alternative to agar-based plate count and other methods for total bacterial counts in nondairy and dairy food products. The pectin gel method has been adopted official first action.

  12. Enumeration of sublethally injured Escherichia coli O157:H7 ATCC 43895 and Escherichia coli strain B-41560 using selective agar overlays versus commercial methods.

    PubMed

    Smith, Amanda R; Ellison, Alysha L; Robinson, Amanda L; Drake, Maryanne; McDowell, Susan A; Mitchell, James K; Gerard, Patrick D; Heckler, Rachel A; McKillip, John L

    2013-04-01

    Quality control procedures during food processing may involve direct inoculation of food samples onto appropriate selective media for subsequent enumeration. However, sublethally injured bacteria often fail to grow, enabling them to evade detection and intervention measures and ultimately threaten the health of consumers. This study compares traditional selective and nonselective agar-based overlays versus two commercial systems (Petrifilm and Easygel) for recovery of injured E. coli B-41560 and O157:H7 strains. Bacteria were propagated in tryptic soy broth (TSB), ground beef slurry, and infant milk formula to a density of 10(6) to 10(8) CFU/ml and then were stressed for 6 min either in lactic acid (pH 4.5) or heat shocked for 3 min at 60°C. Samples were pour plated in basal layers of either tryptic soy agar (TSA), sorbitol MacConkey agar (SMAC), or violet red bile agar (VRB) and were resuscitated for 4 h prior to addition of agar overlays. Other stressed bacteria were plated directly onto Petrifilm and Easygel. Results indicate that selective and nonselective agar overlays recovered significantly higher numbers (greater than 1 log) of acid- and heat-injured E. coli O157:H7 from TSB, ground beef, and infant milk formula compared with direct plating onto selective media, Petrifilm, or Easygel, while no significant differences among these media combinations were observed for stressed E. coli B-41560. Nonstressed bacteria from TSB and ground beef were also recovered at densities significantly higher in nonselective TSA-TSA and in VRB-VRB and SMAC-SMAC compared with Petrifilm and Easygel. These data underscore the need to implement food safety measures that address sublethally injured pathogens such as E. coli O157:H7 in order to avoid underestimation of true densities for target pathogens.

  13. Residual Agar Determination in Bacterial Spores by Electrospray Ionization Mass Spectrometry

    SciTech Connect

    Wahl, Karen L.; Colburn, Heather A.; Wunschel, David S.; Petersen, Catherine E.; Jarman, Kristin H.; Valentine, Nancy B.

    2010-02-15

    Presented here is an analytical method to detect residual agar from a bacterial spore sample as an indication of culturing on an agar plate. This method is based on the resolubilization of agar polysaccharide from a bacterial spore sample, enzymatic digestion, followed by electrospray ionization tandem mass spectrometry (ESI-MSn) analysis for detection of a specific agar fragment ion. A range of Bacillus species and strains were selected to demonstrate the effectiveness of this approach. The characteristic agar fragment ion was detected in the spores grown on agar that were washed from 1 to 5 times, irradiated or non-irradiated and not in the spores grown in broth. A sample containing approximately 108 spores is currently needed for confident detection of residual agar from culture on agar plates in the presence of bacterial spores with a limit of detection of approximately 1 ppm agar spiked into a broth-grown spore sample. The results of a proficiency test with 42 blinded samples are presented demonstrating the utility of this method with no false positives and only 3 false negatives for samples that were below the detection level of the method as documented.

  14. Evaluation of the 3M Petrifilm Enterobacteriaceae Count plate method for the enumeration of Enterobacteriaceae in foods.

    PubMed

    Silbernagel, Karen M; Lindberg, Kathryn G

    2002-09-01

    Results of the 3M Petrifilm Enterobacteriaceae Count (EB) plate method were compared with those of the standard violet red bile glucose agar (VRBG) method for the detection and enumeration of Enterobacteriaceae. Studies involving 107 bacterial strains demonstrated that the Petrifilm EB plate method is as sensitive as and more selective than the VRBG method. Sixty of the 62 pure Enterobacteriaceae cultures were recovered by both methods. In addition, 38 of the 45 non-Enterobacteriaceae organisms did not grow on the Petrifilm EB plate, while 28 of the 45 non-Enterobacteriaceae organisms did not grow on the VRBG plate. Colony counts from 174 naturally contaminated and 120 artificially inoculated dairy and nondairy food samples showed that the Petrifilm EB plate method performed as well as or better than the standard VRBG method for the enumeration of Enterobacteriaceae.

  15. A hidden pitfall in the preparation of agar media undermines microorganism cultivability.

    PubMed

    Tanaka, Tomohiro; Kawasaki, Kosei; Daimon, Serina; Kitagawa, Wataru; Yamamoto, Kyosuke; Tamaki, Hideyuki; Tanaka, Michiko; Nakatsu, Cindy H; Kamagata, Yoichi

    2014-12-01

    Microbiologists have been using agar growth medium for over 120 years. It revolutionized microbiology in the 1890s when microbiologists were seeking effective methods to isolate microorganisms, which led to the successful cultivation of microorganisms as single clones. But there has been a disparity between total cell counts and cultivable cell counts on plates, often referred to as the "great plate count anomaly," that has long been a phenomenon that still remains unsolved. Here, we report that a common practice microbiologists have employed to prepare agar medium has a hidden pitfall: when phosphate was autoclaved together with agar to prepare solid growth media (PT medium), total colony counts were remarkably lower than those grown on agar plates in which phosphate and agar were separately autoclaved and mixed right before solidification (PS medium). We used a pure culture of Gemmatimonas aurantiaca T-27(T) and three representative sources of environmental samples, soil, sediment, and water, as inocula and compared colony counts between PT and PS agar plates. There were higher numbers of CFU on PS medium than on PT medium using G. aurantiaca or any of the environmental samples. Chemical analysis of PT agar plates suggested that hydrogen peroxide was contributing to growth inhibition. Comparison of 454 pyrosequences of the environmental samples to the isolates revealed that taxa grown on PS medium were more reflective of the original community structure than those grown on PT medium. Moreover, more hitherto-uncultivated microbes grew on PS than on PT medium.

  16. A Hidden Pitfall in the Preparation of Agar Media Undermines Microorganism Cultivability

    PubMed Central

    Tanaka, Tomohiro; Kawasaki, Kosei; Daimon, Serina; Kitagawa, Wataru; Yamamoto, Kyosuke; Tamaki, Hideyuki; Tanaka, Michiko; Nakatsu, Cindy H.

    2014-01-01

    Microbiologists have been using agar growth medium for over 120 years. It revolutionized microbiology in the 1890s when microbiologists were seeking effective methods to isolate microorganisms, which led to the successful cultivation of microorganisms as single clones. But there has been a disparity between total cell counts and cultivable cell counts on plates, often referred to as the “great plate count anomaly,” that has long been a phenomenon that still remains unsolved. Here, we report that a common practice microbiologists have employed to prepare agar medium has a hidden pitfall: when phosphate was autoclaved together with agar to prepare solid growth media (PT medium), total colony counts were remarkably lower than those grown on agar plates in which phosphate and agar were separately autoclaved and mixed right before solidification (PS medium). We used a pure culture of Gemmatimonas aurantiaca T-27T and three representative sources of environmental samples, soil, sediment, and water, as inocula and compared colony counts between PT and PS agar plates. There were higher numbers of CFU on PS medium than on PT medium using G. aurantiaca or any of the environmental samples. Chemical analysis of PT agar plates suggested that hydrogen peroxide was contributing to growth inhibition. Comparison of 454 pyrosequences of the environmental samples to the isolates revealed that taxa grown on PS medium were more reflective of the original community structure than those grown on PT medium. Moreover, more hitherto-uncultivated microbes grew on PS than on PT medium. PMID:25281372

  17. Recovery of Sublethally Injured Bacteria Using Selective Agar Overlays.

    ERIC Educational Resources Information Center

    McKillip, John L.

    2001-01-01

    This experiment subjects bacteria in a food sample and an environmental sample to conditions of sublethal stress in order to assess the effectiveness of the agar overlay method to recover sublethally injured cells compared to direct plating onto the appropriate selective medium. (SAH)

  18. Aflatoxin plate kit. Performance Tested Method 081003.

    PubMed

    Trombley, Arthur; Fan, Titan; LaBudde, Robert

    2011-01-01

    The level of total aflatoxin contamination was analyzed in naturally contaminated and spiked samples of corn and peanut using the Aflatoxin Plate Kit. This kit is an enzyme-linked immunosorbent assay (ELISA) suitable for rapid testing of grains and peanuts. The assay was evaluated for ruggedness and linearity of the standard curve. The test kit results were then statistically evaluated for accuracy, precision, and correlation to a validated HPLC method (AOAC 994.08). The results were verified by an independent laboratory.

  19. Detection of intermediately vancomycin-susceptible and heterogeneous Staphylococcus aureus isolates: comparison of Etest and Agar screening methods.

    PubMed

    Riederer, K; Shemes, S; Chase, P; Musta, A; Mar, A; Khatib, R

    2011-06-01

    Detection of Staphylococcus aureus isolates with intermediate vancomycin susceptibility (VISA) and heteroresistance (hVISA) remains problematic. The population analysis profile/area under the curve (PAP/AUC) is the gold standard but is cumbersome. We compared the performance of two Etest screening methods (macromethod [MAC] and glycopeptide resistance detection [GRD]) plus brain heart infusion (BHI) agars supplemented with 3 (BHI-V3) or 4 (BHI-V4) mg/liter vancomycin in detecting hVISA and/or VISA phenotypes. Etest hVISA screenings were done in parallel for 485 saved methicillin-resistant S. aureus (MRSA) blood isolates according to the manufacturer's instructions. The PAP/AUC was measured for all isolates according to the modified method. PAP/AUC test isolate/Mu3 ratios of <0.9, 0.9 to 1.3, and >1.3 were considered positive for susceptible MRSA (S-MRSA), hVISA, and VISA, respectively. PAP/AUC revealed seven VISA and 33 hVISA phenotypes. MAC screening was positive for 30 (75.0%) hVISA/VISA and 49 (11.0%) S-MRSA isolates. GRD screening was positive for 28 (70.0%) hVISA/VISA and 63 (14.2%) S-MRSA isolates. Growth on BHI-V3 was noted in all hVISA/VISA and 24 (5.4%) S-MRSA isolates. Growth on BHI-V4 was noted in all VISA and four (12.1%) hVISA isolates. None of the S-MRSA isolates grew on BHI-V4 agar. The sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values were 75.0%, 89.0%, 38.0%, and 97.5% for MAC; 70.0%, 85.8%, 30.8%, and 97.0% for GRD; 100%, 94.6%, 62.5%, and 100% for BHI-V3; and 100, 99.2%, 63.6%, and 100% for BHI-V4 (for detecting VISA). These findings suggest that both Etest screening methods have excellent NPV, but positive results require confirmation. BHI-V3 and BHI-V4 agars provide more precise identification of hVISA and VISA, respectively; they may be reasonable alternatives to PAP/AUC.

  20. A novel agar formulation for isolation and direct enumeration of Vibrio vulnificus from oyster tissue.

    PubMed

    Griffitt, Kimberly J; Grimes, D Jay

    2013-08-01

    A new selective and differential medium, Vibrio vulnificus X-Gal (VVX), was developed for direct enumeration of V. vulnificus (Vv) from oyster samples. This agar utilizes cellobiose and lactose as carbon sources, and the antibiotics colistin and polymyxin B as selective agents. Hydrolysis of 5-bromo-4-chloro-3-indolyl- beta-d-galactopyranoside (x-gal), used in the agar as a lactose analog, produces an insoluble blue dye that makes lactose positive colonies easily distinguishable from any non-lactose fermenting bacteria. Various bacterial species were spot plated onto thiosulfate-citrate-bile salts-sucrose agar (TCBS), and CHROMagar Vibrio, two vibrio-specific selective agars, non-selective agar, and VVX to compare selectivity of VVX to other widely used media. A V. vulnificus pure culture was serially diluted on VVX and non-selective agar to determine the VVX percent recovery. Water and oyster samples were spread plated on VVX agar and allowed to incubate for 16-18 h at 33 °C. Blue and white colonies from VVX agar were picked and screened by end point PCR for the Vv hemolysin vvhA. VVX agar showed a significant improvement over TCBS and CHROMagar at preventing non-target growth. There was an 87.5% recovery compared to non-selective plating and a 98% positivity rate of blue colonies picked from oyster tissue plating. The findings suggest that this new agar is a fast, distinctive, and accurate method for enumeration of V. vulnificus from the environment.

  1. The agar diffusion scratch assay - A novel method to assess the bioactive and cytotoxic potential of new materials and compounds

    PubMed Central

    Pusnik, Mascha; Imeri, Minire; Deppierraz, Grégoire; Bruinink, Arie; Zinn, Manfred

    2016-01-01

    A profound in vitro evaluation not only of the cytotoxic but also of bioactive potential of a given compound or material is crucial for predicting potential effects in the in vivo situation. However, most of the current methods have weaknesses in either the quantitative or qualitative assessment of cytotoxicity and/or bioactivity of the test compound. Here we describe a novel assay combining the ISO 10993-5 agar diffusion test and the scratch also termed wound healing assay. In contrast to these original tests this assay is able to detect and distinguish between cytotoxic, cell migration modifying and cytotoxic plus cell migration modifying compounds, and this at higher sensitivity and in a quantitative way. PMID:26861591

  2. Collaborative study comparing the spiral plate and aerobic plate count methods.

    PubMed

    Gilchrist, J E; Donnelly, C B; Peeler, J T; Campbell, J E

    1977-07-01

    The spiral plate count method is a semiautomated plating technique that greatly reduces manpower and material costs normally associated with the pour plating technique. In this collaborative study, 8 laboratories compared the spiral and pour plating techniques, using 4 samples each of 3 products: frozen pumpkin pie, frozen chicken pot pie, and shampoo. The results show that 10 of the 12 comparisons of means of the pour and spiral methods were not significantly different; 2 values were significant at alpha = 0.01. Overall, the components of variance were less than that of the current milk standard, and the replicate per cent coefficient of variation was satisfactory. This study indicates that the spiral plate method is an acceptable alternative to the pour plate method; the spiral plate method has been adopted as official first action.

  3. Enumeration of waterborne Escherichia coli with petrifilm plates: comparison to standard methods.

    PubMed

    Vail, J H; Morgan, R; Merino, C R; Gonzales, F; Miller, R; Ram, J L

    2003-01-01

    Escherichia coli is often monitored in environmental waters as an indicator of the possible presence of human pathogens associated with feces. Petrifilm E. coli/coliform count plates (3M, Minneapolis, MN), previously validated for enumerating E. coli in food, were tested for monitoring E. coli in environmental water. Escherichia coli counts in environmental water samples enumerated with Petrifilm were significantly correlated (R > 0.9; slope = 0.9-1.0; p < 0.001) with counts obtained with three commonly used methods, mTEC (Becton Dickinson, Sparks, MD), m-ColiBlue (Hach, Loveland, CO), and Colilert-18/IDEXX Quanti-Tray 2000 (IDEXX, Westbrook, ME). Blue colonies on Petrifilm plates were most reliably identified as E. coli when accompanied by gas formation, as determined by characterization of the colonies on MacConkey agar plates (PML Microbiologicals, Mississauga, ON, Canada) and by polymerase chair reaction (PCR) with E. coli-specific primers. The main disadvantage of Petrifilm plates for environmental water testing is the small volume (1 mL per sample) that can be tested; however, the plates appear to be suitable for screening and locating sites that exceed criteria for total body and partial body contact. Simplicity of use and storage, reliability, and relatively low cost make Petrifilm plates suitable for volunteer-based and educational water quality monitoring applications, particularly when used as a preliminary screening method to identify problem sites.

  4. Microporous microchannel plates and method of manufacturing same

    SciTech Connect

    Beetz, C.P. Jr.; Boerstler, R.W.; Steinbeck, J.; Winn, D.R.

    2000-04-04

    A microchannel plate and method of manufacturing same is provided. The microchannel plate includes a plate consisting of an anodized material and a plurality of channels which are formed during the anodization of the material and extend between the two sides of the plate. Electrodes are also disposed on each side of the plate for generating an electrical field within the channels. Preferably, the material is alumina and the channels are activated such that the channel walls are conductive and highly secondary emissive.

  5. Apparatus and method for controlling plating uniformity

    DOEpatents

    Hachman Jr., John T.; Kelly, James J.; West, Alan C.

    2004-10-12

    The use of an insulating shield for improving the current distribution in an electrochemical plating bath is disclosed. Numerical analysis is used to evaluate the influence of shield shape and position on plating uniformity. Simulation results are compared to experimental data for nickel deposition from a nickel--sulfamate bath. The shield is shown to improve the average current density at a plating surface.

  6. [Detection of TDH-producing Vibrio parahaemolyticus O3:K6 from naturally contaminated shellfish using an immunomagnetic separation method and chromogenic agar medium].

    PubMed

    Hara-Kudo, Y; Sugiyama, K; Nishina, T; Saitoh, A; Nakagawa, H; Ichihara, T; Konuma, H; Hasegawa, J; Kumagai, S

    2001-11-01

    We attempted to isolate TDH-producing Vibrio parahaemolyticus O3:K6 from shellfish. Asari samples were incubated with TSB supplemented with 2% (w/v) NaCl for 6 h, and then the 6-h cultures were incubated with salt polymyxin broth for 18 h. After the two-step enrichment, a 1 ml portion of the culture was treated with magnetic beads coated with K6 antibody for immunoconcentration of V. parahaemolyticus O3:K6. The immunoconcentrated and untreated cultures were plated onto a chromogenic agar and TCBS agar media for isolation of V. parahaemolyticus. TDH-producing V. parahaemolyticus O3:K6 was isolated from 3 out of 66 lots (4.5%) of naturally contaminated Asari. Six of 4,265 colonies suspected as V. parahaemolyticus (0.14%) were TDH-producing V. parahaemolyticus O3:K6.

  7. Performance of the EUCAST disk diffusion method, the CLSI agar screen method, and the Vitek 2 automated antimicrobial susceptibility testing system for detection of clinical isolates of Enterococci with low- and medium-level VanB-type vancomycin resistance: a multicenter study.

    PubMed

    Hegstad, Kristin; Giske, Christian G; Haldorsen, Bjørg; Matuschek, Erika; Schønning, Kristian; Leegaard, Truls M; Kahlmeter, Gunnar; Sundsfjord, Arnfinn

    2014-05-01

    Different antimicrobial susceptibility testing methods to detect low-level vancomycin resistance in enterococci were evaluated in a Scandinavian multicenter study (n=28). A phenotypically and genotypically well-characterized diverse collection of Enterococcus faecalis (n=12) and Enterococcus faecium (n=18) strains with and without nonsusceptibility to vancomycin was examined blindly in Danish (n=5), Norwegian (n=13), and Swedish (n=10) laboratories using the EUCAST disk diffusion method (n=28) and the CLSI agar screen (n=18) or the Vitek 2 system (bioMérieux) (n=5). The EUCAST disk diffusion method (very major error [VME] rate, 7.0%; sensitivity, 0.93; major error [ME] rate, 2.4%; specificity, 0.98) and CLSI agar screen (VME rate, 6.6%; sensitivity, 0.93; ME rate, 5.6%; specificity, 0.94) performed significantly better (P=0.02) than the Vitek 2 system (VME rate, 13%; sensitivity, 0.87; ME rate, 0%; specificity, 1). The performance of the EUCAST disk diffusion method was challenged by differences in vancomycin inhibition zone sizes as well as the experience of the personnel in interpreting fuzzy zone edges as an indication of vancomycin resistance. Laboratories using Oxoid agar (P<0.0001) or Merck Mueller-Hinton (MH) agar (P=0.027) for the disk diffusion assay performed significantly better than did laboratories using BBL MH II medium. Laboratories using Difco brain heart infusion (BHI) agar for the CLSI agar screen performed significantly better (P=0.017) than did those using Oxoid BHI agar. In conclusion, both the EUCAST disk diffusion and CLSI agar screening methods performed acceptably (sensitivity, 0.93; specificity, 0.94 to 0.98) in the detection of VanB-type vancomycin-resistant enterococci with low-level resistance. Importantly, use of the CLSI agar screen requires careful monitoring of the vancomycin concentration in the plates. Moreover, disk diffusion methodology requires that personnel be trained in interpreting zone edges.

  8. Bacterial pathogens of otitis media and sinusitis: detection in the nasopharynx with selective agar media.

    PubMed

    Dudley, S; Ashe, K; Winther, B; Hendley, J O

    2001-11-01

    Carriage rates for the bacterial pathogens associated with otitis media (Streptococcus pneumoniae [SP], Hemophilus influenzae [HI], and Moraxella catarrhalis [MC]) are of interest. Culture on three selective agars was compared with culture on two standard agars to determine the more accurate method for detection of these species in the nasopharynx of healthy children. Weekly samples were obtained in winter from 18 healthy children (ages 1 through 9 years) as part of a longitudinal study. A 0.1-mL sample of 116 nasopharyngeal aspirate/washes was inoculated onto each of five agars. Two were standard (sheep blood and chocolate), and three were selective (blood with gentamicin for SP; chocolate with vancomycin, bacitracin, and clindamycin for HI; blood with amphotericin B, vancomycin, trimethoprim, and acetazolamide for MC). One technician read the standard plates and another the selective; both were blinded to the results of the other. SP was found in 44% of samples with selective agar versus 25% with standard agar; HI was found in 31% with selective versus 9% with standard; MC was found in 56% with selective versus 37% with standard. Overall, 80% of samples had one or more pathogens detected with selective agars as compared with 58% with standard agars (P =.0004). Selective agars were more accurate than standard agars for detecting otitis pathogens in the nasopharynx, where they are a common part of normal flora in healthy children.

  9. The antibacterial activity of sodium hypochlorite and chlorhexidine against Enterococcus faecalis: A review on agar diffusion and direct contact methods

    PubMed Central

    Luddin, Norhayati; Ahmed, Hany Mohamed Aly

    2013-01-01

    Complete debridement and disinfection of the root canal system are fundamental requirements for successful endodontic treatment. Despite the morphological challenges of the internal root anatomy, root canal irrigants play an important role in the optimization of the root canal preparation, which is essentially a chemo-mechanical procedure. Enterococcus faecalis is one of the most resistant microorganisms that dominants the microbial ecosystem of persistent periradicular lesions in retreatment cases. For that reason, many in vitro and in vivo studies evaluated and compared the antibacterial activity of sodium hypochlorite and chlorhexidine at varying concentrations using different experimental models against this microorganism. However, many controversies with regard to the ideal irrigant and concentration do in fact exist. Hence, this review aims to discuss the antibacterial activity of these two main root canal irrigants against Enterococcus faecalis using the agar diffusion and direct contact methods and the possible modulating factors responsible for inconsistent findings among different studies. In addition, the disinfection potential of both chemical agents on gutta percha and Resilon cones are also discussed. The source of this review was conducted through an electronic literature search using PubMed database from December 1997 until December 2011, which analyze the related laboratory investigations of both irrigants, published in major endodontic journals. PMID:23349569

  10. Evaluation of the petrifilm plate method for the enumeration of aerobic microorganisms and coliforms in retailed meat samples.

    PubMed

    Park, Y H; Seo, K S; Ahn, J S; Yoo, H S; Kim, S P

    2001-11-01

    This study was designed to compare the effectiveness and applicability of the Petrifilm plate method with the Association of Official Analytical Chemists' (AOAC) standard aerobic count method and violet red bile agar method for meat products. The comparison was carried out using 303 meat samples collected from various retailers: 110 pork samples, 87 chicken samples, and 107 beef samples. In the comparison of the correlation coefficient (R) between the conventional method and the Petrifilm plate method by a linear regression analysis, the correlation coefficient in total microorganisms was 0.99, 0.95, and 0.94 in pork, beef, and chicken samples, respectively. The correlation coefficient in coliform count was 0.83, 0.96, and 0.81 in pork, beef, and chicken samples, respectively. Based on the high correlation in the total microorganism count, it might be possible to replace the conventional methods with the Petrifilm plate method. For coliform counts, the Petrifilm plate method also showed a generally high correlation coefficient, except for pork samples, which are more subject to contamination. The Petrifilm plate method was simpler and less time-consuming in sample preparation and, in procedures, faster than the conventional method. These results suggested that the 3M Petrifilm plate method could replace the conventional methods in the analysis of microorganism contamination measurement in meat products.

  11. Evaluation of the petrifilm plate method for the enumeration of aerobic microorganisms and coliforms in retailed meat samples.

    PubMed

    Park, Y H; Seo, K S; Ahn, J S; Yoo, H S; Kim, S P

    2001-11-01

    This study was designed to compare the effectiveness and applicability of the Petrifilm plate method with the Association of Official Analytical Chemists' (AOAC) standard aerobic count method and violet red bile agar method for meat products. The comparison was carried out using 303 meat samples collected from various retailers: 110 pork samples, 87 chicken samples, and 107 beef samples. In the comparison of the correlation coefficient (R) between the conventional method and the Petrifilm plate method by a linear regression analysis, the correlation coefficient in total microorganisms was 0.99, 0.95, and 0.94 in pork, beef, and chicken samples, respectively. The correlation coefficient in coliform count was 0.83, 0.96, and 0.81 in pork, beef, and chicken samples, respectively. Based on the high correlation in the total microorganism count, it might be possible to replace the conventional methods with the Petrifilm plate method. For coliform counts, the Petrifilm plate method also showed a generally high correlation coefficient, except for pork samples, which are more subject to contamination. The Petrifilm plate method was simpler and less time-consuming in sample preparation and, in procedures, faster than the conventional method. These results suggested that the 3M Petrifilm plate method could replace the conventional methods in the analysis of microorganism contamination measurement in meat products. PMID:11726171

  12. Vibration of Rectangular Plates Using Plate Characteristic Functions as Shape Functions in the RAYLEIGH RITZ Method

    NASA Astrophysics Data System (ADS)

    Rajalingham, C.; Bhat, R. B.; Xistris, G. D.

    1996-06-01

    The plate characteristic functions are used to express the deflection shapes in the Rayleigh-Ritz method to study rectangular plate vibrations. Since the plate characteristic functions are reasonable approximations to the vibration modes, they are found to improve the convergence of vibration frequencies. These plate frequencies are used to check the accuracy of the Rayleigh frequencies associated with the plate characteristic function modes. Computations are carried out for each of the four mode categories of a clamped square plate. In each mode category, the first 30 natural frequencies are tabulated and the first nine mode diagrams are drawn. The results show that the choice of specific shape functions enhances the effectiveness of the Rayleigh-Ritz method.

  13. [Assessment of 2 automated microdilution techniques compared to an agar dilution method in determining sensitivity to fosfomycin in strains of carbapenem-resistant Pseudomonas aeruginosa].

    PubMed

    Gil-Romero, Yolanda; Regodón-Domínguez, Marta; Wilhelmi de Cal, Isabel; López-Fabal, Fátima; Gómez-Garcés, José Luis

    2016-01-01

    Carbapenems-resistance in Pseudomonas aeruginosa isolates has been widely reported. Fosfomycin has been shown to act synergistically with other antimicrobials. The agar dilution method was approved for susceptibility testing for fosfomycin and Pseudomonas aeruginosa. However, broth microdilution methods are the basis of systems currently used in clinical microbiology laboratories. The results of this study indicate that these methods are acceptable as susceptibility testing methods for fosfomycin against these organisms.

  14. Comparative evaluation of a chromogenic agar medium-PCR protocol with a conventional method for isolation of Vibrio parahaemolyticus strains from environmental and clinical samples.

    PubMed

    Canizalez-Roman, Adrian; Flores-Villaseñor, Héctor; Zazueta-Beltran, Jorge; Muro-Amador, Secundino; León-Sicairos, Nidia

    2011-02-01

    Screening for pathogenic Vibrio parahaemolyticus has become routine in certain areas associated with food-borne outbreaks. This study is an evaluation of the CHROMagar Vibrio (CV) medium-PCR protocol and the conventional method (TCBS (thiosulfate-citrate-bile salts-sucrose) agar plus biochemical and Wagatsuma agar tests) for detection of V. parahaemolyticus in shrimp, water, sediment, and stool samples collected for biosurveillance in an endemic area of northwestern Mexico. A total of 131 environmental and clinical samples were evaluated. The CV medium-PCR protocol showed a significantly improved ability (P < 0.05) to isolate and detect V. parahaemolyticus, identifying isolates of this bacteria missed by the conventional method. Although some other bacteria, distinct from pathogenic V. parahaemolyticus, produced violet colonies similar to that of V. parahaemolyticus on CV medium, we were able to detect a superior number of samples of V. parahaemolyticus with the CV medium-PCR protocol than with the conventional method. The Kanagawa phenomenon is routinely determined on Wagatsuma agar for the diagnosis of V. parahaemolyticus (pathogenic) positive for thermostable direct hemolysin (TDH) in developing countries. In our results, Wagatsuma agar showed low sensitivity (65.4% at 24 h and 75.6% at 48 h) and specificity (52.4% at 48 h) for identifying V. parahaemolyticus positive for TDH. Overall, our data support the use of the CV medium-PCR protocol in place of the conventional method (TCBS-biochemical tests-Wagatsuma agar) for detection of pathogenic V. parahaemolyticus, both in terms of effectiveness and cost efficiency.

  15. Comparison of Results Obtained by Testing with Three Different Agar Media and by the NCCLS M27-A Method for In Vitro Testing of Fluconazole against Candida spp.

    PubMed Central

    Rubio, M. Carmen; Gil, Joaquina; de Ocáriz, Inmaculada Ramírez; Benito, Rafael; Rezusta, Antonio

    2003-01-01

    Fluconazole susceptibilities of 150 Candida isolates were determined by a 25-μg fluconazole disk diffusion agar test and compared with the microdilution NCCLS M27-A method. The agar test used three different media and was read at 24 and 48 h. When only the susceptible and nonsusceptible categories were used, disk diffusion with Müeller-Hinton agar supplemented with 2% glucose and 0.5 μg of methylene blue (MHGM) per ml had a 95.37% correlation with the MIC method at 24 h, followed by RPMI 1640-2% of glucose agar (correlation, 94%) and Shadomy medium (SHDM) (correlation, 92.6%). The growth of microcolonies inside the inhibition zones was common (>63%) in the RPMI and SHDM media and minimal with MHGM (8.7%). At 48 h, MHGM and SHDM still had a >91% correlation with the MIC, while RPMI results had dropped to 75%. The best overall agreement was obtained with C. dubliniensis (100%). PMID:12791899

  16. Ice-Cap: a method for growing Arabidopsis and tomato plants in 96-well plates for high-throughput genotyping.

    PubMed

    Su, Shih-Heng; Clark, Katie A; Gibbs, Nicole M; Bush, Susan M; Krysan, Patrick J

    2011-11-09

    It is becoming common for plant scientists to develop projects that require the genotyping of large numbers of plants. The first step in any genotyping project is to collect a tissue sample from each individual plant. The traditional approach to this task is to sample plants one-at-a-time. If one wishes to genotype hundreds or thousands of individuals, however, using this strategy results in a significant bottleneck in the genotyping pipeline. The Ice-Cap method that we describe here provides a high-throughput solution to this challenge by allowing one scientist to collect tissue from several thousand seedlings in a single day (1,2). This level of throughput is made possible by the fact that tissue is harvested from plants 96-at-a-time, rather than one-at-a-time. The Ice-Cap method provides an integrated platform for performing seedling growth, tissue harvest, and DNA extraction. The basis for Ice-Cap is the growth of seedlings in a stacked pair of 96-well plates. The wells of the upper plate contain plugs of agar growth media on which individual seedlings germinate. The roots grow down through the agar media, exit the upper plate through a hole, and pass into a lower plate containing water. To harvest tissue for DNA extraction, the water in the lower plate containing root tissue is rapidly frozen while the seedlings in the upper plate remain at room temperature. The upper plate is then peeled away from the lower plate, yielding one plate with 96 root tissue samples frozen in ice and one plate with 96 viable seedlings. The technique is named "Ice-Cap" because it uses ice to capture the root tissue. The 96-well plate containing the seedlings can then wrapped in foil and transferred to low temperature. This process suspends further growth of the seedlings, but does not affect their viability. Once genotype analysis has been completed, seedlings with the desired genotype can be transferred from the 96-well plate to soil for further propagation. We have demonstrated

  17. [An observation on the histological structure of Oncomelania hupensis soft tissue by agar-paraffin double-embedding method].

    PubMed

    Tan, Ping; Zhang, Jie; Li, Qing; Yu, Zhi-jun

    2014-12-01

    In order to study the histological structure of Oncomelania hupensis soft tissue, the fixed soft tissues of O. hupensis were pre-embedded in the agar and made blocks, then dehydrated, transparentized, immersed in paraffin, sectioned, and stained with haematoxylin-eosin (HE). Permanent slides of O. hupensis soft tissue were obtained. The histological structure of soft tissues was clear under the microscope.

  18. 21 CFR 582.7115 - Agar-agar.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Agar-agar. 582.7115 Section 582.7115 Food and..., FEEDS, AND RELATED PRODUCTS SUBSTANCES GENERALLY RECOGNIZED AS SAFE Stabilizers § 582.7115 Agar-agar. (a) Product. Agar-agar. (b) Conditions of use. This substance is generally recognized as safe when used...

  19. 21 CFR 582.7115 - Agar-agar.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Agar-agar. 582.7115 Section 582.7115 Food and..., FEEDS, AND RELATED PRODUCTS SUBSTANCES GENERALLY RECOGNIZED AS SAFE Stabilizers § 582.7115 Agar-agar. (a) Product. Agar-agar. (b) Conditions of use. This substance is generally recognized as safe when used...

  20. X-Plate Technology: a new method for detecting fluconazole resistance in Candida species.

    PubMed

    Chadwick, Sean G; Schuyler, Jessica A; Vermitsky, John-Paul; Adelson, Martin E; Mordechai, Eli; Gygax, Scott E

    2013-05-01

    Candida species are responsible for many opportunistic fungal infections. Fluconazole is a well-tolerated antifungal drug, commonly used in the treatment of candidiasis. However, with fluconazole resistance ever increasing, rapid detection and antifungal susceptibility testing of Candida is imperative for proper patient treatment. This paper reports a cost-effective, simple and rapid chromogenic agar dilution method for simultaneous Candida species identification and fluconazole susceptibility testing. The results obtained by X-Plate Technology were in absolute concordance with standard microbroth dilution assays. Analysis of 1383 clinical patient samples with suspected vulvovaginal candidiasis revealed that this technology was able to detect and speciate the Candida isolate and determine the fluconazole susceptibility. The prevalence and susceptibility profiles of the clinical isolates using this method were highly similar to published reports using the microbroth dilution method.

  1. Comparison of Sorbitol MacConkey Agar and a Two-Step Method Which Utilizes Enzyme-Linked Immunosorbent Assay Toxin Testing and a Chromogenic Agar To Detect and Isolate Enterohemorrhagic Escherichia coli

    PubMed Central

    Novicki, Thomas J.; Daly, Judy A.; Mottice, Susan L.; Carroll, Karen C.

    2000-01-01

    Enterohemorrhagic Escherichia coli (EHEC) and specifically serotype O157:H7 are a significant cause of hemorrhagic gastrointestinal disease and the hemolytic uremic syndrome. Methods currently used in clinical microbiology labs, such as sorbitol-MacConkey (SMAC) agar, reliably detect only O157:H7. We have evaluated a two-step method that has the potential to identify and isolate all EHEC serotypes, including serotype O157:H7. This method utilizes a chromogenic selective-differential medium for the isolation of E. coli together with an enzyme-linked immunosorbent assay (ELISA) that detects the Shiga-like toxins Stx1 and Stx2. Both are commercially available and usable in a wide range of clinical microbiology laboratories. Compared to a Vero cell cytotoxic assay, SMAC had sensitivities of 23.5% for the identification of all EHEC serotypes and of 50.0% for the identification of O157:H7 alone. The two-step method had sensitivities of 76.5 and 100%, respectively. The ELISA alone had a sensitivity of 82.4% in the detection of Stx1 and Stx2. The specificity was 100% in all cases. Overall, 14 EHEC isolates were obtained: 8 (58%) O157:H7, 2 (14%) O26, 2 (14%) O111:NM, 1 (7%) O103:H2, and 1 (7%) O121:H19. All but one were isolated during the months of May to September. The two-step method was found to be considerably more expensive than SMAC for both positive and negative samples. PMID:10655343

  2. Evaluation of Bio-Rad MRSASelect agar for detection of methicillin-resistant Staphylococcus aureus directly from blood cultures.

    PubMed

    Riedel, Stefan; Dam, Lisa; Stamper, Paul D; Shah, Syed A R; Carroll, Karen C

    2010-06-01

    MRSASelect agar (Bio-Rad, Redmond, WA) was evaluated for its performance in detecting MRSA directly from positive blood cultures containing Gram-positive cocci in clusters. Agar plates were evaluated for the presence of pink colonies at 18 to 24 h. Results were compared to organism identification by using standard laboratory methods. Confirming coagulase on pink isolates, the sensitivity and specificity were both 99%.

  3. Evaluation and interlaboratory validation of a selective agar for phosphatidylinositol-specific phospholipase C activity using a chromogenic substrate to detect Listeria monocytogenes from foods.

    PubMed

    Jinneman, Karen C; Hunt, Jan M; Eklund, Cheryl A; Wernberg, Jane S; Sado, Patricia N; Johnson, Janelle M; Richter, Richelle S; Torres, Selene T; Ayotte, Eugene; Eliasberg, Stacey J; Istafanos, Phillip; Bass, Deborah; Kexel-Calabresa, Nancy; Lin, Wen; Barton, Curtis N

    2003-03-01

    Phosphatidylinositol-specific phospholipase C (PI-PLC) activity is a potential virulence factor and is exhibited only by the Listeria species Listeria monocytogenes and Listeria ivanovii. A chromogenic substrate for the direct detection of PI-PLC activity is available in a new medium (BCM L. monocytogenes plating agar). The use of a chromogenic substrate offers a mechanism with which to directly screen for L. monocytogenes and L. ivanovii other than the esculin used in Oxford (OXF) and Palcam (PAL) agars, which screen for all Listeria species. The specificity levels of BCM plating agar and of BCM confirmation and rhamnose agars were evaluated with 107 Listeria and 10 Bacillus species isolates. In addition, BCM L. monocytogenes plating agar was compared with standard Listeria selective agars (OXF and PAL agars) with regard to the recovery of L. monocytogenes from 2,000 food and environmental samples obtained from eight participating laboratories. A Listeria species was isolated from at least one of the agars in 209 analyses, and L. monocytogenes was isolated in 135 of these analyses. In 27 of the analyses in which L. monocytogenes was isolated, one or more of the selective differential agars used failed to isolate L. monocytogenes, and therefore the results of these analyses were discrepant. Relative to a reference method involving the use of all three agars (OXF, PAL, and BCM agars), the OXF-BCM, PAL-BCM, and OXF-PAL combinations had sensitivities of 99.3, 99.2, and 90.2%, respectively. In statistical analyses of the different combinations of agars, the OXF-BCM and BCM-PAL combinations were found to be superior to the OXF-PAL combination for the detection of L. monocytogenes.

  4. Conductivity fuel cell collector plate and method of fabrication

    DOEpatents

    Braun, James C.

    2002-01-01

    An improved method of manufacturing a PEM fuel cell collector plate is disclosed. During molding a highly conductive polymer composite is formed having a relatively high polymer concentration along its external surfaces. After molding the polymer rich layer is removed from the land areas by machining, grinding or similar process. This layer removal results in increased overall conductivity of the molded collector plate. The polymer rich surface remains in the collector plate channels, providing increased mechanical strength and other benefits to the channels. The improved method also permits greater mold cavity thickness providing a number of advantages during the molding process.

  5. A method for making an alkaline battery electrode plate

    NASA Technical Reports Server (NTRS)

    Chida, K.; Ezaki, T.

    1983-01-01

    A method is described for making an alkaline battery electrode plate where the desired active substances are filled into a nickel foam substrate. In this substrate an electrolytic oxidation reduction occurs in an alkaline solution containing lithium hydroxide.

  6. 21 CFR 184.1115 - Agar-agar.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Agar-agar. 184.1115 Section 184.1115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN... Substances Affirmed as GRAS § 184.1115 Agar-agar. (a) Agar-agar (CAS Reg. No. PM 9002-18-0) is a...

  7. 21 CFR 184.1115 - Agar-agar.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Agar-agar. 184.1115 Section 184.1115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN... Substances Affirmed as GRAS § 184.1115 Agar-agar. (a) Agar-agar (CAS Reg. No. PM 9002-18-0) is a...

  8. Thermal Analysis of Thin Plates Using the Finite Element Method

    NASA Astrophysics Data System (ADS)

    Er, G. K.; Iu, V. P.; Liu, X. L.

    2010-05-01

    The isotropic thermal plate is analyzed with finite element method. The solution procedure is presented. The elementary stiffness matrix and loading vector are derived rigorously with variation principle and the principle of minimum potential energy. Numerical results are obtained based on the derived equations and tested with available exact solutions. The problems in the finite element analysis are figured out. It is found that the finite element solutions can not converge as the number of elements increases around the corners of the plate. The derived equations presented in this paper are fundamental for our further study on more complicated thermal plate analysis.

  9. Light scattering sensor for real-time identification of Vibrio parahaemolyticus, V. vulnificus and V. cholera colonies on solid agar plates

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The three most common pathogenic species of Vibrio, V. cholerae, V. parahemolyticus and V. vulnificus, are of major concern as water- and food-borne pathogens because of an increasing incidence of water and seafood related outbreaks and illnesses worldwide. Current methods are time-consuming and req...

  10. Xanthan gum: an economical partial substitute for agar in microbial culture media.

    PubMed

    Babbar, Shashi B; Jain, Ruchi

    2006-04-01

    Xanthan gum, microbial desiccation-resistant polysaccharide prepared commercially by aerobic submerged fermentation from Xanthomonas campestris, has been successfully used alone and in combination with agar for microbial culture media. As illustrative examples, eight bacteria and eight fungi were grown on media solidified with either agar (A, 1.5%), xanthan gum (X, 1%), or combinations of both (0.9% X + 0.1% A, 0.8% X + 0.2% A, 0.7% X + 0.3% A, 0.6% X + 0.4% A). All fungi and bacteria exhibited normal growth and differentiation in all these treatments. Rather, growth of most of the fungi was better on xanthan (alone) and xanthan + agar media than agar medium. As the media gelled with xanthan gum alone flow, it was not possible to incubate Petri plates in inverted position. Moreover, because of the softness, streaking of bacteria was difficult on such media. However, these problems could be overcome by partially replacing xanthan gum with 0.3% agar. Bacterial enumeration studies carried out for Serratia sp. and Pseudomonas sp. by serial dilution and pour-plate method on agar (1.5%), 0.7%/0.6% X + 0.3%/0.4% A yielded similar counts. Selective media, succinate medium for Pseudomonas sp., and MacConkey broth medium for Escherichia coli gelled with 0.7%/0.6% X + 0.3%/0.4% A did not support growth of other bacteria when inoculated along with the above-mentioned bacteria. Likewise, differential medium, CRMA (Congo red mannitol agar) gelled with xanthan-agar combination could differentiate between Agrobacterium tumefaciens and Rhizobium sp.

  11. Methicillin-Resistant Staphylococcus aureus (MRSA) Detection: Comparison of Two Molecular Methods (IDI-MRSA PCR Assay and GenoType MRSA Direct PCR Assay) with Three Selective MRSA Agars (MRSA ID, MRSASelect, and CHROMagar MRSA) for Use with Infection-Control Swabs▿

    PubMed Central

    van Hal, S. J.; Stark, D.; Lockwood, B.; Marriott, D.; Harkness, J.

    2007-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is an increasing problem. Rapid detection of MRSA-colonized patients has the potential to limit spread of the organism. We evaluated the sensitivities and specificities of MRSA detection by two molecular methods (IDI-MRSA PCR assay and GenoType MRSA Direct PCR assay) and three selective MRSA agars (MRSA ID, MRSASelect, and CHROMagar MRSA), using 205 (101 nasal, 52 groin, and 52 axillary samples) samples from consecutive known MRSA-infected and/or -colonized patients. All detection methods had higher MRSA detection rates for nasal swabs than for axillary and groin swabs. Detection of MRSA by IDI-MRSA was the most sensitive method, independent of the site (94% for nasal samples, 80% for nonnasal samples, and 90% overall). The sensitivities of the GenoType MRSA Direct assay and the MRSA ID, MRSASelect, and CHROMagar MRSA agars with nasal swabs were 70%, 72%, 68%, and 75%, respectively. All detection methods had high specificities (95 to 99%), independent of the swab site. Extended incubation for a further 24 h with selective MRSA agars increased the detection of MRSA, with a corresponding decline in specificity secondary to a significant increase in false-positive results. There was a noticeable difference in test performance of the GenoType MRSA Direct assay in detection of MRSA (28/38 samples [74%]) compared with detection of nonmultiresistant MRSA (17/31 samples [55%]) (susceptible to two or more non-β-lactam antibiotics). This was not observed with selective MRSA agar plates or IDI-MRSA. Although it is more expensive, in addition to rapid turnaround times of 2 to 4 h, IDI-MRSA offers greater detection of MRSA colonization, independent of the swab site, than do conventional selective agars and GenoType MRSA Direct. PMID:17537949

  12. Recovery of spores of Clostridium botulinum in yeast extract agar and pork infusion agar after heat treatment.

    PubMed

    Odlaug, T E; Pflug, I J

    1977-10-01

    Yeast extract agar, pork infusion agar, and modifications of these media were used to recover heated Clostridium botulinum spores. The D- and z-values were determined. Two type A strains and one type B strain of C. botulinum were studied. In all cases the D-values were largest when the spores were recovered in yeast extract agar, compared to the D-values for spores recovered in pork infusion agar. The z-values for strains 62A and A16037 were largest when the spores were recovered in pork infusion agar. The addition of sodium bicarbonate and sodium thioglycolate to pork infusion agar resulted in D-values for C. botulinum 62A spores similar to those for the same spores recovered in yeast extract agar. The results suggest that sodium bicarbonate and sodium thioglycolate should be added to recovery media for heated C. botulinum spores to obtain maximum plate counts. PMID:335970

  13. Bacteria holding times for fecal coliform by mFC agar method and total coliform and Escherichia coli by Colilert®-18 Quanti-Tray® method

    USGS Publications Warehouse

    Aulenbach, Brent T.

    2010-01-01

    Bacteria holding-time experiments of up to 62 h were performed on five surface-water samples from four urban stream sites in the vicinity of Atlanta, GA, USA that had relatively high densities of coliform bacteria (Escherichia coli densities were all well above the US Environmental Protection Agency criterion of 126 colonies (100 ml) − 1 for recreational waters). Holding-time experiments were done for fecal coliform using the membrane filtration modified fecal coliform (mFC) agar method and for total coliform and E. coli using the Colilert®-18 Quanti-Tray® method. The precisions of these analytical methods were quantified. Precisions determined for fecal coliform indicated that the upper bound of the ideal range of counts could reasonably be extended upward and would improve precision. For the Colilert®-18 method, analytical precisions were similar to the theoretical precisions for this method. Fecal and total coliform densities did not change significantly with holding times up to about 27 h. Limited information indicated that fecal coliform densities might be stable for holding times of up to 62 h, whereas total coliform densities might not be stable for holding times greater than about 27 h. E. coli densities were stable for holding times of up to 18 h—a shorter period than indicated from a previous studies. These results should be applicable to non-regulatory monitoring sampling designs for similar urban surface-water sample types.

  14. Method to reduce damage to backing plate

    DOEpatents

    Perry, Michael D.; Banks, Paul S.; Stuart, Brent C.

    2001-01-01

    The present invention is a method for penetrating a workpiece using an ultra-short pulse laser beam without causing damage to subsequent surfaces facing the laser. Several embodiments are shown which place holes in fuel injectors without damaging the back surface of the sack in which the fuel is ejected. In one embodiment, pulses from an ultra short pulse laser remove about 10 nm to 1000 nm of material per pulse. In one embodiment, a plasma source is attached to the fuel injector and initiated by common methods such as microwave energy. In another embodiment of the invention, the sack void is filled with a solid. In one other embodiment, a high viscosity liquid is placed within the sack. In general, high-viscosity liquids preferably used in this invention should have a high damage threshold and have a diffusing property.

  15. The Application of Optimisation Methods to Constrain Absolute Plate Motions

    NASA Astrophysics Data System (ADS)

    Tetley, M. G.; Williams, S.; Hardy, S.; Müller, D.

    2015-12-01

    Plate tectonic reconstructions are an excellent tool for understanding the configuration and behaviour of continents through time on both global and regional scales, and are relatively well understood back to ~200 Ma. However, many of these models represent only relative motions between continents, providing little information of absolute tectonic motions and their relationship with the deep Earth. Significant issues exist in solving this problem, including how to combine constraints from multiple, diverse data into a unified model of absolute plate motions; and how to address uncertainties both in the available data, and in the assumptions involved in this process (e.g. hotspot motion, true polar wander). In deep time (pre-Pangea breakup), plate reconstructions rely more heavily on paleomagnetism, but these data often imply plate velocities much larger than those observed since the breakup of the supercontinent Pangea where plate velocities are constrained by the seafloor spreading record. Here we present two complementary techniques to address these issues, applying parallelized numerical methods to quantitatively investigate absolute plate motions through time. Firstly, we develop a data-fit optimized global absolute reference frame constrained by kinematic reconstruction data, hotspot-trail observations, and trench migration statistics. Secondly we calculate optimized paleomagnetic data-derived apparent polar wander paths (APWPs) for both the Phanerozoic and Precambrian. Paths are generated from raw pole data with optimal spatial and temporal pole configurations calculated using all known uncertainties and quality criteria to produce velocity-optimized absolute motion paths through deep time.

  16. Crystal formation in furunculosis agar

    USGS Publications Warehouse

    Bullock, G.L.; Ross, A.J.

    1964-01-01

    SINCE ITS INTRODUCTION SOME MONTHS AGO, FURUNCULOSIS AGAR has been employed in the diagnosis of suspect furunculosis and also as a general purpose medium. During our work with this medium we have noticed discrete "colonies," of crystalline material, which very closely resemble microbial colonies. These crystal colonies are compact and appear on both the surface and subsurface; they occur in inoculated slants and plates incubated for long periods (2 to 3 weeks), as well as in uninoculated stored medium. As the crystal colonies could be confusing to workers using this medium, we decided to attempt to identify them and also to determine whether storage conditions and different lots of medium affect crystal formation.

  17. Method for conducting electroless metal-plating processes

    DOEpatents

    Petit, George S.; Wright, Ralph R.

    1978-01-01

    This invention is an improved method for conducting electroless metal-plating processes in a metal tank which is exposed to the plating bath. The invention solves a problem commonly encountered in such processes: how to determine when it is advisable to shutdown the process in order to clean and/or re-passivate the tank. The new method comprises contacting the bath with a current-conducting, non-catalytic probe and, during plating operations, monitoring the gradually changing difference in electropotential between the probe and tank. It has been found that the value of this voltage is indicative of the extent to which nickel-bearing decomposition products accumulate on the tank. By utilizing the voltage to determine when shutdown for cleaning is advisable, the operator can avoid premature shutdown and at the same time avoid prolonging operations to the point that spontaneous decomposition occurs.

  18. Inverse methods-based estimation of plate coupling in a plate motion model governed by mantle flow

    NASA Astrophysics Data System (ADS)

    Ratnaswamy, V.; Stadler, G.; Gurnis, M.

    2013-12-01

    Plate motion is primarily controlled by buoyancy (slab pull) which occurs at convergent plate margins where oceanic plates undergo deformation near the seismogenic zone. Yielding within subducting plates, lateral variations in viscosity, and the strength of seismic coupling between plate margins likely have an important control on plate motion. Here, we wish to infer the inter-plate coupling for different subduction zones, and develop a method for inferring it as a PDE-constrained optimization problem, where the cost functional is the misfit in plate velocities and is constrained by the nonlinear Stokes equation. The inverse models have well resolved slabs, plates, and plate margins in addition to a power law rheology with yielding in the upper mantle. Additionally, a Newton method is used to solve the nonlinear Stokes equation with viscosity bounds. We infer plate boundary strength using an inexact Gauss-Newton method with line search for backtracking. Each inverse model is applied to two simple 2-D scenarios (each with three subduction zones), one with back-arc spreading and one without. For each case we examine the sensitivity of the inversion to the amount of surface velocity used: 1) full surface velocity data and 2) surface velocity data simplified using a single scalar average (2-D equivalent to an Euler pole) for each plate. We can recover plate boundary strength in each case, even in the presence of highly nonlinear flow with extreme variations in viscosity. Additionally, we ascribe an uncertainty in each plate's velocity and perform an uncertainty quantification (UQ) through the Hessian of the misfit in plate velocities. We find that as plate boundaries become strongly coupled, the uncertainty in the inferred plate boundary strength decreases. For very weak, uncoupled subduction zones, the uncertainty of inferred plate margin strength increases since there is little sensitivity between plate margin strength and plate velocity. This result is significant

  19. Standardized methods and quality control limits for agar and broth microdilution susceptibility testing of Mycoplasma pneumoniae, Mycoplasma hominis, and Ureaplasma urealyticum.

    PubMed

    Waites, Ken B; Duffy, Lynn B; Bébéar, Cécile M; Matlow, Anne; Talkington, Deborah F; Kenny, George E; Totten, Patricia A; Bade, Donald J; Zheng, Xiaotian; Davidson, Maureen K; Shortridge, Virginia D; Watts, Jeffrey L; Brown, Steven D

    2012-11-01

    An international multilaboratory collaborative study was conducted to develop standard media and consensus methods for the performance and quality control of antimicrobial susceptibility testing of Mycoplasma pneumoniae, Mycoplasma hominis, and Ureaplasma urealyticum using broth microdilution and agar dilution techniques. A reference strain from the American Type Culture Collection was designated for each species, which was to be used for quality control purposes. Repeat testing of replicate samples of each reference strain by participating laboratories utilizing both methods and different lots of media enabled a 3- to 4-dilution MIC range to be established for drugs in several different classes, including tetracyclines, macrolides, ketolides, lincosamides, and fluoroquinolones. This represents the first multilaboratory collaboration to standardize susceptibility testing methods and to designate quality control parameters to ensure accurate and reliable assay results for mycoplasmas and ureaplasmas that infect humans.

  20. Differential recovery of Streptococcus mutans from various mitis-salivarius agar preparations.

    PubMed Central

    Liljemark, W F; Okrent, D H; Bloomquist, C G

    1976-01-01

    Recoveries of Streptococcus mutans from human dental plaque were lower when plated on mitis-salivarius agar obtained from Baltimore Biological Laboratories as compared with mitis-salivarius agar obtained from Difco Laboratories. However, no difference in recoveries of established laboratory strains of S. mutans was observed between these two agar preparations. PMID:956358

  1. Linear transformation method to control flexural waves in thin plates.

    PubMed

    Liu, Yongquan; Ma, Zhaoyang; Su, Xianyue

    2016-08-01

    In this paper, the linear transformation method (LTM) to control flexural waves propagating in thin plates is presented. Unlike earlier studies, only a small number of homogeneous materials with no requirement of in-plane forces or pre-stress are needed, which tremendously simplifies the implementation of devices for flexural waves. An invisibility cloak with homogeneous materials is studied to confirm the validity of the present approach, and to show its imperfection due to impedance mismatch at interfaces. Required materials can be further simplified as layered isotropic materials using the effective medium theory. Finally, the LTM can be extended to the case of flexural waves propagating in anisotropic thin plates. The present method opens a promising avenue toward the realization of advanced structured shields and other devices. PMID:27586744

  2. Syneresis in agar hydrogels.

    PubMed

    Boral, Shilpi; Saxena, Anita; Bohidar, H B

    2010-03-01

    Agar hydrogels exhibit syneresis which creates internal osmotic stress on the physical network. It was observed that such a stress gives rise to characteristic pulsating modes (breathing modes). Experiments carried over a period of 60-day revealed that the network deformations grew monotonously when the solvent released by syneresis was removed periodically from gel surface. However, when the solvent was not withdrawn, the gel exhibited very slowly relaxing breathing modes. The swelling-deswelling dynamics has been discussed in the generalized framework of a dissipative damped oscillator.

  3. DAFS measurements using the image-plate Weissenberg method.

    PubMed

    Sugioka, N; Matsumoto, K; Tanaka, M; Mori, T; Sasaki, S

    1998-05-01

    An instrumental technique for DAFS measurements which can provide site-specific information is proposed. The approach uses (i) focusing optics with parabolic mirrors and a double-crystal monochromator, (ii) the Laue and Bragg settings and (iii) data collection by the image-plate Weissenberg method. Six image exposures are recorded per plate at five intrinsic energies and one reference energy. The single-crystal measurements were performed at the Co K-absorption edge, and the 200, 220 and 311 reflections of CoO and 511 and 911 reflections of Co(3)O(4) were used for analysis. The regression analysis of chi(k), Fourier transforms of k(3)chi(k) and back-Fourier filtering have been performed.

  4. Rapid and Sensitive Plate Method for Detection of Aspergillus fumigatus

    PubMed Central

    Bauters, T. G. M.; Nelis, H. J.

    2000-01-01

    The routine identification of Aspergillus fumigatus in clinical samples involves, apart from direct examination, the isolation of the organism on a plate followed by its microscopic characterization. This approach lacks sensitivity, specificity, and speed. A new procedure has been developed combining microcolony formation on a nylon membrane filter at 45°C with the detection of a specific 4-methylumbelliferyl-α-l-arabinopyranoside cleaving enzyme activity in digitonin permeabilized cells. The test takes approximately 14 h and has an efficiency of 98.2% and false-positive and -negative rates of 0 and 3.1%, respectively. When applied to 188 clinical samples taken from patients with proven or nonproven presence of Aspergillus species, a good agreement with the conventional plate-microscopy method was obtained. PMID:11015405

  5. Performance of CHROMAGAR candida and BIGGY agar for identification of yeast species

    PubMed Central

    Yücesoy, Mine; Marol, Serhat

    2003-01-01

    Background The importance of identifying the pathogenic fungi rapidly has encouraged the development of differential media for the presumptive identification of yeasts. In this study two differential media, CHROMagar Candida and bismuth sulphite glucose glycine yeast agar, were evaluated for the presumptive identification of yeast species. Methods A total number of 270 yeast strains including 169 Candida albicans, 33 C. tropicalis, 24 C. glabrata, 18 C. parapsilosis, 12 C. krusei, 5 Trichosporon spp., 4 C. kefyr, 2 C. lusitaniae, 1 Saccharomyces cerevisiae and 1 Geotrichum candidum were included. The strains were first identified by germ tube test, morphological characteristics on cornmeal tween 80 agar and Vitek 32 and API 20 C AUX systems. In parallel, they were also streaked onto CHROMagar Candida and bismuth sulphite glucose glycine yeast agar plates. The results were read according to the color, morphology of the colonies and the existance of halo around them after 48 hours of incubation at 37°C. Results The sensitivity and specificity values for C. albicans strains were found to be 99.4, 100% for CHROMagar Candida and 87.0, 75.2% for BiGGY agar, respectively. The sensitivity of CHROMagar Candida to identify C. tropicalis, C. glabrata and C. krusei ranged between 90.9 and 100% while the specificity was 100%. The sensitivity rates for BiGGY agar were 66.6 and 100% while the specificity values were found to be 95.4 and 100% for C. tropicalis and C. krusei, respectively. Conclusions It can be concluded that the use of CHROMagar Candida is an easy and reliable method for the presumptive identification of most commonly isolated Candida species especially C. albicans, C. tropicalis and C. krusei. The lower sensitivity and specificity of BiGGY agar to identify commonly isolated Candida species potentially limits the clinical usefulness of this agar. PMID:14613587

  6. Finite strip method combined with other numerical methods for the analysis of plates

    NASA Astrophysics Data System (ADS)

    Cheung, M. S.; Li, Wenchang

    1992-09-01

    Finite plate strips are combined with finite elements or boundary elements in the analysis of rectangular plates with some minor irregularities such as openings, skew edges, etc. The plate is divided into regular and irregular regions. The regular region is analyzed by the finite strip method while the irregular one is analyzed by the finite element or boundary element method. A special transition element and strip are developed in order to connect the both regions. Numerical examples will show the accuracy and efficiency of this combined analysis.

  7. Comparison of a rapid ATP bioluminescence assay and standard plate count methods for assessing microbial contamination of consumers' refrigerators.

    PubMed

    Chen, Fur-Chi; Godwin, Sandria L

    2006-10-01

    The feasibility of using an ATP bioluminescence assay for assessing microbial contamination of home refrigerators was evaluated and compared with the standard culture methods. Samples of refrigerator surfaces were collected from 123 households by swabbing an area of 100 cm2 on three locations in the refrigerator with premoisturized sterile swabs. Microbial contaminations were determined by aerobic plate count (APC; incubated at 35 degrees C for 48 h) and psychrotrophic plate count (PPC; incubated at 7 degrees C for 10 days) on plate count agar. The results were compared to the readings from the microbial ATP (mATP) bioluminescence assay. The correlation coefficient (r) between mATP and PPC (r = 0.851) was slightly higher than that between mATP and APC (r = 0.823). Our results indicated a potential discrepancy in the population of mesophilic and psychrotrophic bacteria in the refrigerator samples. Nevertheless, mATP appeared to be a reliable indication of the average of APC and PPC (r = 0.895). The mATP bioluminescence assay would provide a rapid and convenient test for researchers in field studies to assess microbial contamination in refrigerators.

  8. Enumeration of total aerobic microorganisms in foods by SimPlate Total Plate Count-Color Indicator methods and conventional culture methods: collaborative study.

    PubMed

    Feldsine, Philip T; Leung, Stephanie C; Lienau, Andrew H; Mui, Linda A; Townsend, David E

    2003-01-01

    The relative efficacy of the SimPlate Total Plate Count-Color Indicator (TPC-CI) method (SimPlate 35 degrees C) was compared with the AOAC Official Method 966.23 (AOAC 35 degrees C) for enumeration of total aerobic microorganisms in foods. The SimPlate TPC-CI method, incubated at 30 degrees C (SimPlate 30 degrees C), was also compared with the International Organization for Standardization (ISO) 4833 method (ISO 30 degrees C). Six food types were analyzed: ground black pepper, flour, nut meats, frozen hamburger patties, frozen fruits, and fresh vegetables. All foods tested were naturally contaminated. Nineteen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery among the SimPlate methods and their corresponding reference methods. Mean log counts between the 2 reference methods were also very similar. Repeatability (Sr) and reproducibility (SR) standard deviations were similar among the 3 method comparisons. The SimPlate method (35 degrees C) and the AOAC method were comparable for enumerating total aerobic microorganisms in foods. Similarly, the SimPlate method (30 degrees C) was comparable to the ISO method when samples were prepared and incubated according to the ISO method.

  9. Thermal diffusivity of nonflat plates using the flash method

    SciTech Connect

    Salazar, Agustin; Fuente, Raquel; Apinaniz, Estibaliz; Mendioroz, Arantza

    2011-01-15

    The flash method is the standard technique to measure the thermal diffusivity of solid samples. It consists of heating the front surface of an opaque sample by a brief light pulse and detecting the temperature evolution at its rear surface. The thermal diffusivity is obtained by measuring the time corresponding to the half maximum of the temperature rise, which only depends on the sample thickness and thermal diffusivity through a simple formula. Up to now, the flash method has been restricted to flat samples. In this work, we extend the flash method to measure the thermal diffusivity of nonflat samples. In particular, we focus on plates with cylindrical and spherical shapes. The theoretical model indicates that the same expression for flat samples can also be applied to cylindrical and spherical plates, except for extremely curved samples. Accordingly, a curvature limit for the application of the expression for flat samples is established. Flash measurements on lead foils of cylindrical shape confirm the validity of the model.

  10. "Paraffin wax-overlay of pour plate", a method for the isolation and enumeration of purple non-sulfur bacteria.

    PubMed

    Archana, A; Sasikala, Ch; Ramana, Ch V; Arunasri, K

    2004-12-01

    A modification of pour plate technique with an overlay of wax was used for isolation and enumeration of purple non-sulfur bacteria (PNSB) with equal efficiency as that of agar shake culture. The total count of PNSB ranged from 10(5)-10(8) CFU g dry soil(-1) and belonged to the genera of Rhodobacter, Rhodopseudomonas, Rhodocista and Rubrivivax.

  11. 21 CFR 184.1115 - Agar-agar.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Agar-agar. 184.1115 Section 184.1115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) DIRECT FOOD SUBSTANCES AFFIRMED AS GENERALLY RECOGNIZED AS SAFE Listing of...

  12. 21 CFR 184.1115 - Agar-agar.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Agar-agar. 184.1115 Section 184.1115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) DIRECT FOOD SUBSTANCES AFFIRMED AS GENERALLY RECOGNIZED AS SAFE Listing of...

  13. 21 CFR 184.1115 - Agar-agar.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Agar-agar. 184.1115 Section 184.1115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DIRECT FOOD... ingredient meets the specifications of the “Food Chemicals Codex,” 3d Ed. (1981), p. 11, which...

  14. [Clinical utility of Pourmedia GBS agar on screening for vaginal colonization of Group B Streptococcus].

    PubMed

    Kaneda, Mitsunori; Nagasaki, Hiromi; Tasaki, Megumi; Kamiyama, Kiyoshi

    2014-01-01

    Group B Streptococcus (GBS) are normal flora of the vagina and intestinal, but if the pregnant woman was infected with GBS in the vagina, miscarriage or premature would occur or the newborn would be developed to severe GBS infection. It is recommended that the inspection of GBS on all pregnant women by Japan Society of Obstetrics and Gynecology (JSOG) and Center for Disease Control and Prevention (CDC). We examined the comparison of detection rate between Pourmedia GBS agar (Eiken Chemical Co., Ltd.) and Nissui Separated Plate Sheep Blood Agar/BTB Lactose Agar medium (Nissui Pharmaceutical Co., Ltd.) on 112 sample. The positive rate of Pourmedia GBS agar was 21.4% (24/112 samples), Whereas Nissui Separated Plate Sheep Blood Agar/BTB Lactose Agar medium was 17.8% (20/112 samples). It was found that the detection rate was improved by using Pourmedia GBS agar on GBS screening test of vaginal swab.

  15. An Evaluation Method for the Suppression of Pathogenic Fusarium oxysporum by Soil Microorganisms Using the Dilution Plate Technique.

    PubMed

    Mitsuboshi, Masahiro; Kioka, Yuuzou; Noguchi, Katsunori; Asakawa, Susumu

    2016-09-29

    Soil-borne diseases caused by pathogenic microorganisms are one of the main factors responsible for the decline in crop yields in farmlands. Pathogenic Fusarium oxysporum causes serious damage to various crops, and, thus, a feasible diagnostic method for soil-borne diseases is required. We herein examined a simple method to evaluate the suppressiveness of soil microorganisms against a pathogen by co-cultivating indigenous soil microorganisms and a pathogenic fungus (F. oxysporum f. sp. spinaciae). We inoculated F. oxysporum onto the center of agar medium plates mixed with a dilution series of a suspension of organic fertilizers or soil. After an approximately one-week cultivation, the growth degree of F. oxysporum was estimated based on the size of the colonies that formed on the plates. The growth degree of F. oxysporum significantly differed among the organic fertilizers tested, indicating the usefulness of the method for evaluating suppressiveness by organic fertilizers. Differences in the growth degrees of F. oxysporum were associated with the incidence of disease in spinach on soil treated with organic fertilizers and inoculated with a pathogenic F. oxysporum strain. These results suggested that this method provides some useful information on the suppressiveness of organic fertilizers and soil against Fusarium wilt. PMID:27558588

  16. An Evaluation Method for the Suppression of Pathogenic Fusarium oxysporum by Soil Microorganisms Using the Dilution Plate Technique

    PubMed Central

    Mitsuboshi, Masahiro; Kioka, Yuuzou; Noguchi, Katsunori; Asakawa, Susumu

    2016-01-01

    Soil-borne diseases caused by pathogenic microorganisms are one of the main factors responsible for the decline in crop yields in farmlands. Pathogenic Fusarium oxysporum causes serious damage to various crops, and, thus, a feasible diagnostic method for soil-borne diseases is required. We herein examined a simple method to evaluate the suppressiveness of soil microorganisms against a pathogen by co-cultivating indigenous soil microorganisms and a pathogenic fungus (F. oxysporum f. sp. spinaciae). We inoculated F. oxysporum onto the center of agar medium plates mixed with a dilution series of a suspension of organic fertilizers or soil. After an approximately one-week cultivation, the growth degree of F. oxysporum was estimated based on the size of the colonies that formed on the plates. The growth degree of F. oxysporum significantly differed among the organic fertilizers tested, indicating the usefulness of the method for evaluating suppressiveness by organic fertilizers. Differences in the growth degrees of F. oxysporum were associated with the incidence of disease in spinach on soil treated with organic fertilizers and inoculated with a pathogenic F. oxysporum strain. These results suggested that this method provides some useful information on the suppressiveness of organic fertilizers and soil against Fusarium wilt. PMID:27558588

  17. Comparative evaluation of the VITEK 2, disk diffusion, etest, broth microdilution, and agar dilution susceptibility testing methods for colistin in clinical isolates, including heteroresistant Enterobacter cloacae and Acinetobacter baumannii strains.

    PubMed

    Lo-Ten-Foe, Jerome R; de Smet, Anne Marie G A; Diederen, Bram M W; Kluytmans, Jan A J W; van Keulen, Peter H J

    2007-10-01

    Increasing antibiotic resistance in gram-negative bacteria has recently renewed interest in colistin as a therapeutic option. The increasing use of colistin necessitates the availability of rapid and reliable methods for colistin susceptibility testing. We compared seven methods of colistin susceptibility testing (disk diffusion, agar dilution on Mueller-Hinton [MH] and Isosensitest agar, Etest on MH and Isosensitest agar, broth microdilution, and VITEK 2) on 102 clinical isolates collected from patient materials during a selective digestive decontamination or selective oral decontamination trial in an intensive-care unit. Disk diffusion is an unreliable method to measure susceptibility to colistin. High error rates and low levels of reproducibility were observed in the disk diffusion test. The colistin Etest, agar dilution, and the VITEK 2 showed a high level of agreement with the broth microdilution reference method. Heteroresistance for colistin was observed in six Enterobacter cloacae isolates and in one Acinetobacter baumannii isolate. This is the first report of heteroresistance to colistin in E. cloacae isolates. Resistance to colistin in these isolates seemed to be induced upon exposure to colistin rather than being caused by stable mutations. Heteroresistant isolates could be detected in the broth microdilution, agar dilution, Etest, or disk diffusion test. The VITEK 2 displayed low sensitivity in the detection of heteroresistant subpopulations of E. cloacae. The VITEK 2 colistin susceptibility test can therefore be considered to be a reliable tool to determine susceptibility to colistin in isolates of genera that are known not to exhibit resistant subpopulations. In isolates of genera known to (occasionally) exhibit heteroresistance, an alternative susceptibility testing method capable of detecting heteroresistance should be used.

  18. Use of Dehydrated Agar to Estimate Microbial Water Quality for Horticulture Irrigation.

    PubMed

    Meador, Dustin P; Fisher, Paul R; Guy, Charles L; Harmon, Philip F; Peres, Natalia A; Teplitski, Max

    2016-07-01

    Petrifilms are dehydrated agar culture plates that have been used to quantify colony forming units (CFU) mL of either aerobic bacteria (Petrifilm-AC) or fungus (Petrifilm-YM), depending on substrate composition. Microbes in irrigation systems can indicate biofilm risk and potential clogging of irrigation emitters. The research objective was to compare counts on Petrifilms versus traditional, hydrated-agar plates using samples collected from recirculated irrigation waters and cultures of isolated known species. The estimated count (in CFU mL) from a recirculated irrigation sample after 7 d of incubation on Petrifilm-YM was only 5.5% of the count quantified using sabouraud dextrose agar (SDA) with chloramphenicol after 14 d. In a separate experiment with a known species, Petrifilm-YM did not successfully culture zoospores of . Isolates of viable zoospores were cultured successfully on potato-dextrose agar (PDA), with comparable counts with a vegetable juice medium supplemented with the antibiotics pimaricin, ampicillin, rifamycin, pentochloronitrobenzene and hymexazol (PARP-H). The quantification of pv. Begoniaceae on Petrifilm-AC was not significantly different ( < 0.05) than on PDA, but was lower than on Reasoner and Goldrich agar (R2A) or with a hemocytometer. The current formulation of Petrifilm-YM is unlikely to be a useful monitoring method for plant pathogens in irrigation water because of the inability to successfully culture oomycetes. However, Petrifilm-AC was an effective method to quantify bacteria and can provide an easy-to-use on-farm tool to monitor biofilm risk and microbial density.

  19. Use of Dehydrated Agar to Estimate Microbial Water Quality for Horticulture Irrigation.

    PubMed

    Meador, Dustin P; Fisher, Paul R; Guy, Charles L; Harmon, Philip F; Peres, Natalia A; Teplitski, Max

    2016-07-01

    Petrifilms are dehydrated agar culture plates that have been used to quantify colony forming units (CFU) mL of either aerobic bacteria (Petrifilm-AC) or fungus (Petrifilm-YM), depending on substrate composition. Microbes in irrigation systems can indicate biofilm risk and potential clogging of irrigation emitters. The research objective was to compare counts on Petrifilms versus traditional, hydrated-agar plates using samples collected from recirculated irrigation waters and cultures of isolated known species. The estimated count (in CFU mL) from a recirculated irrigation sample after 7 d of incubation on Petrifilm-YM was only 5.5% of the count quantified using sabouraud dextrose agar (SDA) with chloramphenicol after 14 d. In a separate experiment with a known species, Petrifilm-YM did not successfully culture zoospores of . Isolates of viable zoospores were cultured successfully on potato-dextrose agar (PDA), with comparable counts with a vegetable juice medium supplemented with the antibiotics pimaricin, ampicillin, rifamycin, pentochloronitrobenzene and hymexazol (PARP-H). The quantification of pv. Begoniaceae on Petrifilm-AC was not significantly different ( < 0.05) than on PDA, but was lower than on Reasoner and Goldrich agar (R2A) or with a hemocytometer. The current formulation of Petrifilm-YM is unlikely to be a useful monitoring method for plant pathogens in irrigation water because of the inability to successfully culture oomycetes. However, Petrifilm-AC was an effective method to quantify bacteria and can provide an easy-to-use on-farm tool to monitor biofilm risk and microbial density. PMID:27380096

  20. Susceptibility of a polycaprolactone-based root canal filling material to degradation using an agar-well diffusion assay

    PubMed Central

    Hiraishi, Noriko; Sadek, Fernanda T.; King, Nigel M.; Ferrari, Marco; Pashley, David H.; Tay, Franklin R

    2013-01-01

    Purpose Cholesterol esterase is both a component of salivary hydrolases as well as an inflammatory cell-derived enzyme and has been shown to cause biodegradation of methacrylate-based resin composites. This study examined whether Resilon, a polycaprolactone-based thermoplastic root filling material is susceptible to biodegradation by cholesterol esterase using agar-well diffusion assay of serially-diluted aqueous Resilon emulsions that were dispersed in agar. Materials and methods Emulsions of Resilon and polycaprolactone were prepared and dispersed in agar on culture plates. Two different concentrations of a cholesterol esterase (0.3 and 1.2 U/mL) were prepared and fed to wells prepared in the agar plates using an agar-well diffusion assay for examination the degradation of polymeric materials. Results Degradation of the emulsified Resilon was manifested as the formation of clear zones of different sizes around the agar wells. No clear zones were observed in agar wells that contain sterile distilled water as the negative control. Clinical significance Although dispersion Resilon into an emulsion is not the way in which this material is employed as a root filling material, the potential for Resilon to be degraded by cholesterol esterase is of potential concern as one cannot limit the degradation of extruded Resilon from a root apex by monocyte-derived macrophages to just the anatomical root apex. As the present study employed a high concentration of cholesterol esterase, further studies should be directed to examining the degradation of Resilon using macrophage cell cultures. PMID:18578181

  1. Comparison of Fecal Coliform Agar and Violet Red Bile Lactose Agar for Fecal Coliform Enumeration in Foods

    PubMed Central

    Leclercq, A.; Wanegue, C.; Baylac, P.

    2002-01-01

    A 24-h direct plating method for fecal coliform enumeration with a resuscitation step (preincubation for 2 h at 37 ± 1°C and transfer to 44 ± 1°C for 22 h) using fecal coliform agar (FCA) was compared with the 24-h standardized violet red bile lactose agar (VRBL) method. FCA and VRBL have equivalent specificities and sensitivities, except for lactose-positive non-fecal coliforms such as Hafnia alvei, which could form typical colonies on FCA and VRBL. Recovery of cold-stressed Escherichia coli in mashed potatoes on FCA was about 1 log unit lower than that with VRBL. When the FCA method was compared with standard VRBL for enumeration of fecal coliforms, based on counting carried out on 170 different food samples, results were not significantly different (P > 0.05). Based on 203 typical identified colonies selected as found on VRBL and FCA, the latter medium appears to allow the enumeration of more true fecal coliforms and has higher performance in certain ways (specificity, sensitivity, and negative and positive predictive values) than VRBL. Most colonies clearly identified on both media were E. coli and H. alvei, a non-fecal coliform. Therefore, the replacement of fecal coliform enumeration by E. coli enumeration to estimate food sanitary quality should be recommended. PMID:11916678

  2. Comparative evaluation of chromogenic agar medium and conventional culture system for isolation and presumptive identification of uropathogens

    PubMed Central

    Akter, Laila; Haque, Rezwana; Salam, Md. Abdus

    2014-01-01

    Objective: Urine is the most frequent specimen received for culture/sensitivity by clinical laboratories. The microbiological performance of HiCrome UTI agar medium was compared with Blood agar and MacConkey agar for isolation and presumptive identification of bacteria from urine culture. Methods: A total of 443 consecutively collected midstream and/or catheter-catch urine samples from patients attending the Islami Bank Medical College Hospital, Rajshahi, Bangladesh during January to December, 2012 were cultured. Urine samples showing pus cells ≥ 5/HPF were inoculated on to Blood agar (BA), MacConkey agar (MAC) and HiCrome UTI agar (CA) media simultaneously and incubated overnight aerobically at 370C. Rate of isolation and presumptive identification of bacterial species were compared for different media. Results: Culture yielded a total of 199 bacterial isolates from 189 (42.67%) positive plates including 179 (40.40%) unimicrobial and 10 (2.26%) polymicrobial (mixed growth of pair of bacteria) growths. Both HiCrome UTI agar and Blood agar media supported 100% growths while 151 (75.88%) growths were observed on MacConkey agar. The rate of presumptive identification was found significantly higher on HiCrome UTI agar (97.49%) than MAC agar (67.34%) (P<0.001) as primary urine culture medium. Of 199 isolates, E. coli was found to be the leading uropathogen isolated from 118 (59.30%) samples with its presumptive identification rate of 95.76%, 93.22% and 5.93% on CA, MAC and BA respectively. All 10 (100%) polymicrobial growths were demonstrated distinctly on CA against only 01(10%) on each BA and MAC. Conclusion: HiCrome UTI agar was found to be more useful as primary urine culture medium in both higher rate of isolation and presumptive identification of uropathogens in comparison to conventional media. Its inherent characteristics in demonstrating polymicrobial growth and ease of rapid identification by distinct colony colour are unique. PMID:25225521

  3. Heterotrophic plate count methodology in the United States.

    PubMed

    Reasoner, Donald J

    2004-05-01

    In the United States (US), the history of bacterial plate counting (BPC) methods used for water can be traced largely through Standard Methods for the Examination of Water and Wastewater (Standard Methods). The bacterial count method has evolved from the original Standard Methods (1st edition, 1905) plate count which used nutrient gelatin and incubation at 20 degrees C for 48 h, to the HPC method options in the latest edition of Standard Methods that provide greater flexibility of application, depending on the data needs of the water analyst. The use of agar-agar as a gelling agent, replacing gelatin, allowed the use of higher incubation temperatures and resulted in the "body temperature count" (37 degrees C) found in the 3rd through the 8th edition of Standard Methods. The change from 37 degrees C incubation to 35+/-0.5 degrees C accommodated laboratories that did both milk and water analyses. By using a single temperature, fewer incubators were needed. The term "standard plate count" (SPC) first appeared in 1960 (11th edition) along with plate count agar. Incubation at 20 degrees C for the plate count was dropped from the 13th to 15th editions and few changes were made in the SPC method from the 11th edition through the 13th editions. Plate count analysis of bottled waters was included in the 14th edition (1975), calling for incubation at 35+/-0.5 degrees C for 72+/-4 h. Perhaps the most significant changes in plate count methods occurred with the 16th edition (1985). The term heterotrophic plate count replaced the standard plate count, and the spread plate (SP) and membrane filter (MF) methods were added along with new media for pour and spread plates (R2A agar and NWRI agar, both low nutrient) and for the membrane filter method (mHPC medium). The use of low nutrient media, lower incubation temperature, and longer incubation times, results in higher plate count results for most water samples. The options currently available, including low and high nutrient media

  4. Method for Reduction of Silver Biocide Plating on Metal Surfaces

    NASA Technical Reports Server (NTRS)

    Steele, John; Nalette, Timothy; Beringer, Durwood

    2013-01-01

    Silver ions in aqueous solutions (0.05 to 1 ppm) are used for microbial control in water systems. The silver ions remain in solution when stored in plastic containers, but the concentration rapidly decreases to non-biocidal levels when stored in metal containers. The silver deposits onto the surface and is reduced to non-biocidal silver metal when it contacts less noble metal surfaces, including stainless steel, titanium, and nickel-based alloys. Five methods of treatment of contact metal surfaces to deter silver deposition and reduction are proposed: (1) High-temperature oxidation of the metal surface; (2) High-concentration silver solution pre-treatment; (3) Silver plating; (4) Teflon coat by vapor deposition (titanium only); and (5) A combination of methods (1) and (2), which proved to be the best method for the nickel-based alloy application. The mechanism associated with surface treatments (1), (2), and (5) is thought to be the development of a less active oxide layer that deters ionic silver deposition. Mechanism (3) is an attempt to develop an equilibrium ionic silver concentration via dissolution of metallic silver. Mechanism (4) provides a non-reactive barrier to deter ionic silver plating. Development testing has shown that ionic silver in aqueous solution was maintained at essentially the same level of addition (0.4 ppm) for up to 15 months with method (5) (a combination of methods (1) and (2)), before the test was discontinued for nickel-based alloys. Method (1) resulted in the maintenance of a biocidal level (approximately 0.05 ppm) for up to 10 months before that test was discontinued for nickel-based alloys. Methods (1) and (2) used separately were able to maintain ionic silver in aqueous solution at essentially the same level of addition (0.4 ppm) for up to 10 months before the test was discontinued for stainless steel alloys. Method (3) was only utilized for titanium alloys, and was successful at maintaining ionic silver in aqueous solution at

  5. A comparison of a new centrifuge sugar flotation technique with the agar method for the extraction of immature Culicoides (Diptera: Ceratopogonidae) life stages from salt marsh soils.

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Two sampling techniques, agar extraction (AE) and centrifuge sugar flotation extraction (CSFE) were compared to determine their relative efficacy to recover immature stages of Culicoides spp from salt marsh substrates. Three types of samples (seeded with known numbers of larvae, homogenized field s...

  6. Models of convection-driven tectonic plates - A comparison of methods and results

    NASA Technical Reports Server (NTRS)

    King, Scott D.; Gable, Carl W.; Weinstein, Stuart A.

    1992-01-01

    Recent numerical studies of convection in the earth's mantle have included various features of plate tectonics. This paper describes three methods of modeling plates: through material properties, through force balance, and through a thin power-law sheet approximation. The results obtained are compared using each method on a series of simple calculations. From these results, scaling relations between the different parameterizations are developed. While each method produces different degrees of deformation within the surface plate, the surface heat flux and average plate velocity agree to within a few percent. The main results are not dependent upon the plate modeling method and herefore are representative of the physical system modeled.

  7. Campylobacter in broiler slaughter samples assessed by direct count on mCCDA and Campy-Cefex agar.

    PubMed

    Gonsalves, Camila Cristina; Borsoi, Anderlise; Perdoncini, Gustavo; Rodrigues, Laura Beatriz; do Nascimento, Vladimir Pinheiro

    2016-01-01

    Campylobacter spp. cause foodborne illnesses in humans primarily through the consumption of contaminated chicken. The aim of this study was to evaluate the United States Department of Agriculture's (USDA) recommended methodology, protocol MLG 41.02, for the isolation, identification and direct plate counting of Campylobacter jejuni and C. coli samples from the broiler slaughtering process. A plating method using both mCCDA and Campy-Cefex agars is recommended to recover Campylobacter cells. It is also possible to use this method in different matrices (cloacal swabs and water samples). Cloacal swabs, samples from pre-chiller and post-chiller carcasses and samples of pre-chiller, chiller and direct supply water were collected each week for four weeks from the same flock at a slaughterhouse located in an abattoir in southern Brazil. Samples were analyzed to directly count Campylobacter spp., and the results showed a high frequency of Campylobacter spp. on Campy-Cefex agar. For the isolated species, 72% were identified as Campylobacter jejuni and 38% as Campylobacter coli. It was possible to count Campylobacter jejuni and Campylobacter coli from different samples, including the water supply samples, using the two-agar method. These results suggest that slaughterhouses can use direct counting methods with both agars and different matrices as a monitoring tool to assess the presence of Campylobacter bacteria in their products. PMID:27237112

  8. [Titration of Ebola and Marburg viruses by plaque formation under semi liquid agar].

    PubMed

    Ustinova, E N; Shestopalov, A M; Bakulina, L F; Chepurnov, A A

    2003-01-01

    The method of titration of Ebola and Marburg viruses using plaque formation under semifluid agar cover is considered. Advantages of this method over conventional method of titration of these viruses with the use of hard agar cover are discussed.

  9. Abilities of the mCP Agar method and CRENAME alpha toxin-specific real-time PCR assay to detect Clostridium perfringens spores in drinking water.

    PubMed

    Maheux, Andrée F; Bérubé, Eve; Boudreau, Dominique K; Villéger, Romain; Cantin, Philippe; Boissinot, Maurice; Bissonnette, Luc; Bergeron, Michel G

    2013-12-01

    We first determined the analytical specificity and ubiquity (i.e., the ability to detect all or most strains) of a Clostridium perfringens-specific real-time PCR (rtPCR) assay based on the cpa gene (cpa rtPCR) by using a bacterial strain panel composed of C. perfringens and non-C. perfringens Clostridium strains. All non-C. perfringens Clostridium strains tested negative, whereas all C. perfringens strains tested positive with the cpa rtPCR, for an analytical specificity and ubiquity of 100%. The cpa rtPCR assay was then used to confirm the identity of 116 putative C. perfringens isolates recovered after filtration of water samples and culture on mCP agar. Colonies presenting discordant results between the phenotype on mCP agar and cpa rtPCR were identified by sequencing the 16S rRNA and cpa genes. Four mCP(-)/rtPCR(+) colonies were identified as C. perfringens, whereas 3 mCP(+)/rtPCR(-) colonies were identified as non-C. perfringens. The cpa rtPCR was negative with all 51 non-C. perfringens strains and positive with 64 of 65 C. perfringens strains. Finally, we compared mCP agar and a CRENAME (concentration and recovery of microbial particles, extraction of nucleic acids, and molecular enrichment) procedure plus cpa rtPCR (CRENAME + cpa rtPCR) for their abilities to detect C. perfringens spores in drinking water. CRENAME + cpa rtPCR detected as few as one C. perfringens CFU per 100 ml of drinking water sample in less than 5 h, whereas mCP agar took at least 25 h to deliver results. CRENAME + cpa rtPCR also allows the simultaneous and sensitive detection of Escherichia coli and C. perfringens from the same potable water sample. In itself, it could be used to assess the public health risk posed by drinking water potentially contaminated with pathogens more resistant to disinfection.

  10. Growth of Desulfovibrio on the Surface of Agar Media

    PubMed Central

    Iverson, Warren P.

    1966-01-01

    Growth of Desulfovibrio desulfuricans (API strain) was found to take place in an atmosphere of hydrogen on the agar surface of complex media, including yeast extract (Difco), and Trypticase Soy Agar (BBL) without any added reducing agents. For growth on a 2% yeast extract-agar surface in the absence of hydrogen (nitrogen atmosphere), sodium lactate was required in the medium. Growth on the surface of Trypticase Soy Agar (TSA) under nitrogen took place readily in the absence of an added hydrogen donor. A medium (TSA plus salts) is described based upon the addition of sodium lactate (4 ml per liter), magnesium sulfate (2 g per liter), and ferrous ammonium sulfate (0.05%) to TSA, which appears suitable for the isolation and growth of Desulfovibrio on the surface of agar plates in an atmosphere of hydrogen. Sodium lactate does not appear to be essential in this medium for good growth and sulfate reduction in a hydrogen atmosphere, but is essential in a nitrogen atmosphere. Growth of Desulfovibrio (hydrogen atmosphere) on the agar surface of media commonly used for its cultivation as well as on an inorganic medium containing bicarbonate as a source of carbon is poor and erratic unless inoculated (Desulfovibrio) plates of TSA plus salts are incubated in the same container with plates of these media. This stimulatory effect of incubation with inoculated plates of TSA plus salts medium appears to be due to as yet unidentified volatile material produced by D. desulfuricans when growing on this medium. Another volatile material, or possibly the identical material, appears to act similarly to a hydrogen donor. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 PMID:5955798

  11. Direct identification and recognition of yeast species from clinical material by using albicans ID and CHROMagar Candida plates.

    PubMed Central

    Baumgartner, C; Freydiere, A M; Gille, Y

    1996-01-01

    Two chromogenic media, Albicans ID and CHROMagar Candida agar plates, were compared with a reference medium, Sabouraud-chloramphenicol agar, and standard methods for the identification of yeast species. This study involved 951 clinical specimens. The detection rates for the two chromogenic media for polymicrobial specimens were 20% higher than that for the Sabouraud-chloramphenicol agar plates. The rates of identification of Candida albicans for Albicans ID and CHROMagar Candida agar plates were, respectively, 37.0 and 6.0% after 24 h of incubation and 93.6 and 92.2% after 72 h of incubation, with specificities of 99.8 and 100%. Furthermore, CHROMagar Candida plates identified 13 of 14 Candida tropicalis and 9 of 12 Candida krusei strains after 48 h of incubation. PMID:8789038

  12. A comparative study of biofilm formation by Shiga toxigenic Escherichia coli using epifluorescence microscopy on stainless steel and a microtitre plate method.

    PubMed

    Rivas, Lucia; Dykes, Gary A; Fegan, Narelle

    2007-04-01

    Attachment of Shiga toxigenic Escherichia coli (STEC) to surfaces and the formation of biofilms may enhance persistence in a food processing environment and present a risk of contaminating products. Seven strains of STEC and three non-STEC strains were selected to compare two biofilm quantification methods; epifluorescence microscopy on stainless steel (SS) and a microtitre plate assay. The influence of prior growth in planktonic (nutrient broth) and sessile (nutrient agar) culture on biofilm production, as well as expression of surface structures and the possession of antigen 43 (encoded by agn43) on biofilm formation were also investigated. Biofilms were produced in diluted nutrient broth at 25 degrees C for 24 and 48 h. Curli expression was determined using congo red indicator agar, while the presence of agn43 was determined using polymerase chain reaction. No correlation was found between counts for epifluorescence microscopy on SS and the absorbance values obtained with the microtitre plate method for planktonic and sessile grown cultures. Different abilities of individual STEC strains to attach to SS and microtitre plates were found with some strains attaching better to each surface following growth in either planktonic or sessile culture. All O157 STEC strains had low biofilm counts on SS for planktonic and sessile grown cultures; however, one STEC O157:H- strain (EC516) had significantly greater (p<0.05) biofilm production on microtitre plates compared to the other O157 STEC strains. EC516 and other STEC (O174:H21 and O91:H21) strains expressing curli fimbriae were found to produce significantly greater (p<0.05) biofilms on microtitre plates compared to the non-curli expressing strains. No relationship was found between the production of type-I fimbriae, motility, agn43 and bacterial physicochemical properties (previously determined) and biofilm formation on SS or microtitre plates. Variations between the two biofilm determination methods may suggest that

  13. Perforated plates for cryogenic regenerators and method of fabrication

    DOEpatents

    Hendricks, J.B.

    1994-03-29

    Perforated plates having very small holes with a uniform diameter throughout the plate thickness are prepared by a [open quotes]wire drawing[close quotes] process in which a billet of sacrificial metal is disposed in an extrusion can of the plate metal, and the can is extruded and restacked repeatedly, converting the billet to a wire of the desired hole diameter. At final size, the rod is then sliced into wafers, and the wires are removed by selective etching. This process is useful for plate metals of interest for high performance regenerator applications, in particular, copper, niobium, molybdenum, erbium, and other rare earth metals. Er[sub 3]Ni, which has uniquely favorable thermophysical properties for such applications, may be incorporated in regions of the plates by providing extrusion cans containing erbium and nickel metals in a stacked array with extrusion cans of the plate metal, which may be copper. The array is heated to convert the erbium and nickel metals to Er[sub 3]Ni. Perforated plates having two sizes of perforations, one of which is small enough for storage of helium, are also disclosed. 10 figures.

  14. Perforated plates for cryogenic regenerators and method of fabrication

    DOEpatents

    Hendricks, John B.

    1994-01-01

    Perforated plates (10) having very small holes (14) with a uniform diameter throughout the plate thickness are prepared by a "wire drawing" process in which a billet of sacrificial metal is disposed in an extrusion can of the plate metal, and the can is extruded and restacked repeatedly, converting the billet to a wire of the desired hole diameter. At final size, the rod is then sliced into wafers, and the wires are removed by selective etching. This process is useful for plate metals of interest for high performance regenerator applications, in particular, copper, niobium, molybdenum, erbium, and other rare earth metals. Er.sub.3 Ni, which has uniquely favorable thermophysical properties for such applications, may be incorporated in regions of the plates by providing extrusion cans (20) containing erbium and nickel metals in a stacked array (53) with extrusion cans of the plate metal, which may be copper. The array is heated to convert the erbium and nickel metals to Er.sub.3 Ni. Perforated plates having two sizes of perforations (38, 42), one of which is small enough for storage of helium, are also disclosed.

  15. Comparison of Assurance GDS(®) MPX ID for Top STEC with Reference Culture Methods for the Detection of E. coli Top 6 STEC; Direct Confirmation of Top 6 STEC from Isolation Plates and Determination of Equivalence of PickPen(®) and FSIS OctoMACS™ Concentration Protocols.

    PubMed

    Feldsine, Philip; Lienau, Andrew H; Shah, Khyati; Immermann, Amy; Soliven, Khanh; Kaur, Mandeep; Kerr, David E; Jucker, Markus; Hammack, Tom; Brodsky, Michael; Agin, James

    2016-01-01

    Assurance GDS(®) MPX ID for Top Shiga toxin-producing Escherichia coli (STEC; MPX ID) was validated according to the AOAC INTERNATIONAL Methods Committee Guidelines for Validation of Microbiological Methods for Foods and Environmental Surfaces as (1) a secondary screening method for specific detection of the Top 6 STEC serogroups (O26, O45, O103, O111, O121, and O145) in raw beef trim, raw ground beef, raw spinach, and on stainless steel; and (2) as a confirmatory method for the identification of pure culture isolates as Top 6 STEC. MPX ID is used in conjunction with the upfront BCS Assurance GDS MPX Top 7 STEC assay. This Performance Tested Method(SM) validation has two main parts: Method Developer studies and the Independent Laboratory study. A total of 180 samples and controls were analyzed. Results showed that MPX ID had no statistically significant differences with the reference culture methods for the detection of Top 6 STEC in the food matrixes (raw beef trim, raw ground beef, and raw spinach) and environmental sponges (stainless steel) studied. Inclusivity/exclusivity studies were also conducted. One hundred percent inclusivity among the 50 Top 6 STEC serovars tested and 100% exclusivity for the 30 non-Top 6 STEC organisms tested were demonstrated. For validation of MPX ID as a confirmatory method for isolated colonies, all inclusivity and exclusivity organisms were streaked for isolation onto five STEC plating media: modified rainbow agar, Levine's eosin-methylene blue (L-EMB) agar, rainbow agar with novobiocin and cefixime, and enterohemolysin agar with selective agents as well as trypticase soy agar with yeast extract. These isolated colonies were suspended and analyzed by Assurance GDS MPX Top 7 STEC and MPX ID. MPX ID was able to correctly confirm all inclusivity organisms from all plate types, except two STEC isolates from L-EMB agar plates only in the Independent Laboratory study. All exclusivity organisms were correctly determined by MPX ID as non

  16. Method for regeneration of electroless nickel plating solution

    DOEpatents

    Eisenmann, E.T.

    1997-03-11

    An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorus acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution. 1 fig.

  17. Method for regeneration of electroless nickel plating solution

    DOEpatents

    Eisenmann, Erhard T.

    1997-01-01

    An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorous acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution.

  18. Effect of refrigerated storage on cefaclor in Mueller-Hinton agar.

    PubMed Central

    Surprenant, A M; Preston, D A

    1985-01-01

    Cefaclor is less stable than most cephalosporins in media at 35 degrees C. We demonstrated that the activity of cefaclor in Mueller-Hinton agar diminishes continuously at 4 degrees C, resulting in a loss of two-thirds of the activity within 21 days. We recommend that agar dilution plates for this cephalosporin be prepared on the day of their use. PMID:3968200

  19. Abilities of the mCP Agar Method and CRENAME Alpha Toxin-Specific Real-Time PCR Assay To Detect Clostridium perfringens Spores in Drinking Water

    PubMed Central

    Maheux, Andrée F.; Bérubé, Ève; Boudreau, Dominique K.; Villéger, Romain; Cantin, Philippe; Boissinot, Maurice; Bissonnette, Luc

    2013-01-01

    We first determined the analytical specificity and ubiquity (i.e., the ability to detect all or most strains) of a Clostridium perfringens-specific real-time PCR (rtPCR) assay based on the cpa gene (cpa rtPCR) by using a bacterial strain panel composed of C. perfringens and non-C. perfringens Clostridium strains. All non-C. perfringens Clostridium strains tested negative, whereas all C. perfringens strains tested positive with the cpa rtPCR, for an analytical specificity and ubiquity of 100%. The cpa rtPCR assay was then used to confirm the identity of 116 putative C. perfringens isolates recovered after filtration of water samples and culture on mCP agar. Colonies presenting discordant results between the phenotype on mCP agar and cpa rtPCR were identified by sequencing the 16S rRNA and cpa genes. Four mCP−/rtPCR+ colonies were identified as C. perfringens, whereas 3 mCP+/rtPCR− colonies were identified as non-C. perfringens. The cpa rtPCR was negative with all 51 non-C. perfringens strains and positive with 64 of 65 C. perfringens strains. Finally, we compared mCP agar and a CRENAME (concentration and recovery of microbial particles, extraction of nucleic acids, and molecular enrichment) procedure plus cpa rtPCR (CRENAME + cpa rtPCR) for their abilities to detect C. perfringens spores in drinking water. CRENAME + cpa rtPCR detected as few as one C. perfringens CFU per 100 ml of drinking water sample in less than 5 h, whereas mCP agar took at least 25 h to deliver results. CRENAME + cpa rtPCR also allows the simultaneous and sensitive detection of Escherichia coli and C. perfringens from the same potable water sample. In itself, it could be used to assess the public health risk posed by drinking water potentially contaminated with pathogens more resistant to disinfection. PMID:24077714

  20. Vibration Analysis of Annular Plates with Concentric Supports Using a Variant of Rayleigh-Ritz Method

    NASA Astrophysics Data System (ADS)

    Wang, C. M.; Thevendran, V.

    1993-05-01

    A variant of the Rayleigh-Ritz method is presented for solving the free vibration problem of annular plates with internal axisymmetric supports. The method is simple, accurate and may be readily programmed and run on a microcomputer. A comprehensive tabulation of the fundamental frequencies is presented for isotropic annular plates with an internal concentric support. Results for full circular plates with concentric supports are also obtained by making the inner radial edge free and permitting the inner radius to become very small.

  1. Method and apparatus for enhancing microchannel plate data

    DOEpatents

    Thoe, R.S.

    1983-10-24

    A method and apparatus for determining centroid channel locations are disclosed for use in a system activated by one or more multichannel plates and including a linear diode array providing channels of information 1, 2, ...,n, ..., N containing signal amplitudes A/sub n/. A source of analog A/sub n/ signals, and a source of digital clock signals n, are provided. Non-zero A/sub n/ values are detected in a discriminator. A digital signal representing p, the value of n immediately preceding that whereat A/sub n/ takes its first non-zero value, is generated in a scaler. The analog A/sub n/ signals are converted to digital in an analog to digital converter. The digital A/sub n/ signals are added to produce a digital ..sigma..A/sub n/ signal in a full adder. Digital 1, 2, ..., m signals representing the number of non-zero A/sub n/ are produced by a discriminator pulse counter. Digital signals representing 1 A/sub p+1/, 2 A/sub p+2/, ..., m A/sub p+m/ are produced by pairwise multiplication in multiplier. These signal are added in multiplier summer to produce a digital ..sigma..nA/sub n/ - p..sigma..A/sub n/ signal. This signal is divided by the digital ..sigma..A/sub n/ signal in divider to provide a digital (..sigma..nA/sub n//..sigma..A/sub n/) -p signal. Finally, this last signal is added to the digital p signal in an offset summer to provide ..sigma..nA/sub n//..sigma..A/sub n/, the centroid channel locations.

  2. Method and apparatus for enhancing microchannel plate data

    DOEpatents

    Thoe, Robert S.

    1987-01-01

    A method and apparatus for determining centroid channel locations is disclosed for use in a system activated by one or more multichannel plates (16,18) and including a linear diode array (24) providing channels of information 1, 2, . . . , n, . . . , N containing signal amplitudes A.sub.n. A source of analog A.sub.n signals (40), and a source of digital clock signals n (48), are provided. Non-zero A.sub.n values are detected in a discriminator (42). A digital signal representing p, the value of n immediately preceding that whereat A.sub.n takes its first non-zero value, is generated in a scaler (50). The analog A.sub.n signals are converted to digital in an analog to digital converter (44). The digital A.sub.n signals are added to produce a digital .SIGMA.A.sub.n signal in a full adder (46). Digital 1, 2, . . . , m signals representing the number of non-zero A.sub.n are produced by a discriminator pulse counter (52). Digital signals representing 1 A.sub.p+ 1, 2 A.sub.p+2, . . . , m A.sub.p+m are produced by pairwise multiplication in multiplier (54). These signals are added in multiplier summer (56) to produce a digital .SIGMA.nA.sub.n -p.SIGMA.A.sub.n signal. This signal is divided by the digital .SIGMA.A.sub.n signal in divider (58) to provide a digital (.SIGMA.nA.sub.n /.SIGMA.A.sub.n) -p signal. Finally, this last signal is added to the digital p signal in an offset summer (60) to provide .SIGMA.nA.sub.n /.SIGMA.A.sub.n, the centroid channel locations.

  3. Vibration Analysis of Corner Supported Mindlin Plates of Arbitrary Shape Using the Lagrange Multiplier Method

    NASA Astrophysics Data System (ADS)

    Kitipornchai, S.; Xiang, Y.; Liew, K. M.

    1994-06-01

    This paper presents the first known solutions of the problem of free flexural vibration of corner supported Mindlin plates of arbitrary shape. A hybrid numerical approach combining the Rayleigh-Ritz method and the Lagrange multiplier method has been developed to solve the plate vibration problem. The algorithm uses the pb-2 shape functions to account for different geometries, and Lagrange multipliers to impose zero lateral deflection constraints at plate corners. The method of solution is applicable to arbitrarily shaped plates with corner supports. In this paper, however, only triangular, skew and annular sector plates are chosen for the purpose of demonstration. Some comparison studies for corner supported thin square plates are made to verify the accuracy of the derived solutions.

  4. Fuel cell collector plate and method of fabrication

    DOEpatents

    Braun, James C.; Zabriskie, Jr., John E.; Neutzler, Jay K.; Fuchs, Michel; Gustafson, Robert C.

    2001-01-01

    An improved molding composition is provided for compression molding or injection molding a current collector plate for a polymer electrolyte membrane fuel cell. The molding composition is comprised of a polymer resin combined with a low surface area, highly-conductive carbon and/or graphite powder filler. The low viscosity of the thermoplastic resin combined with the reduced filler particle surface area provide a moldable composition which can be fabricated into a current collector plate having improved current collecting capacity vis-a-vis comparable fluoropolymer molding compositions.

  5. 48 CFR 401.371 - AGAR Advisories.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false AGAR Advisories. 401.371... ACQUISITION REGULATION SYSTEM Agency Acquisition Regulations 401.371 AGAR Advisories. The SPE may issue AGAR Advisories, consistent with the policies of the FAR and the AGAR, for the following purposes: (a)...

  6. 48 CFR 401.371 - AGAR Advisories.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false AGAR Advisories. 401.371... ACQUISITION REGULATION SYSTEM Agency Acquisition Regulations 401.371 AGAR Advisories. The SPE may issue AGAR Advisories, consistent with the policies of the FAR and the AGAR, for the following purposes: (a)...

  7. Method for in-situ nondestructive measurement of Young's modulus of plate structures

    NASA Technical Reports Server (NTRS)

    Huang, Jerry Qixin (Inventor); Perez, Robert J. (Inventor); DeLangis, Leo M. (Inventor)

    2003-01-01

    A method for determining stiffness of a composite laminate plate entails disposing a device for generating an acoustical pulse against a surface of the plate and disposing a detecting device against the same surface spaced a known distance from the pulse-generating device, and using the pulse-generating device to emit a pulse so as to create an extensional wave in the plate. The detecting device is used to determine a time of flight of the wave over the known distance, and the wave velocity is calculated. A Young's modulus of the plate is determined based on the wave velocity. Methods for both anisotropic and quasi-isotropic laminates are disclosed.

  8. Computed radiography imaging plates and associated methods of manufacture

    SciTech Connect

    Henry, Nathaniel F.; Moses, Alex K.

    2015-08-18

    Computed radiography imaging plates incorporating an intensifying material that is coupled to or intermixed with the phosphor layer, allowing electrons and/or low energy x-rays to impart their energy on the phosphor layer, while decreasing internal scattering and increasing resolution. The radiation needed to perform radiography can also be reduced as a result.

  9. Evaluation of eight agar media for the isolation of shiga toxin-Producing Escherichia coli.

    PubMed

    Gill, Alexander; Huszczynski, George; Gauthier, Martine; Blais, Burton

    2014-01-01

    The growth characteristics of 96 shiga toxin-producing Escherichia coli (STEC) strains representing 36 different O-types (including priority O types O26, O45, O103, O111, O121, O145 and O157) on commercial and in-house agar media were studied. The ability of the strains to grow on agar media with varying selective supplement formulations was evaluated using MacConkey Agar (MAC); Rainbow® Agar O157 (RBA); Rainbow® Agar O157 with manufacturer-recommended selective supplements (RBA-NT); Rainbow® Agar O157 with USDA-recommended selective supplements (RBA-USDA); CHROMagar STEC™ (CH STEC); Tryptone Bile agar containing cefixime and tellurite (TBA-CT); Tryptone Bile agar containing cefixime, tellurite, eosin and methylene blue (TBA-EM); and VTEC agar. All of the strains were able to grow on MAC, RBA and VTEC agar, whereas a number of strains (including some non-O157 priority O types) were unable to grow on the highly selective media CH STEC, RBA-NT, RBA-USDA, TBA-EM and TBA-CT. Only RBA-NT and CH STEC exhibited significant inhibition of background flora from ground beef enrichment. Significant inhibition of background flora from beef trim enrichment was observed with RBA-NT, RBA-USDA, CH STEC, TBA-EM and VTEC agar. With exception of E. coli O157, several different colony morphologies were observed on the differential plating media among strains of the same O type, indicating that this colony morphology is not a reliable means of identifying target STEC. These results suggest that an approach to maximize the recovery of target STEC from beef enrichment cultures is dual plating on lesser (RBA, MAC, VTEC agar) and more highly (RBA-NT, CH STEC) selective agars.

  10. Method of obtaining intensified image from developed photographic films and plates

    NASA Technical Reports Server (NTRS)

    Askins, B. S. (Inventor)

    1978-01-01

    A method is explained of obtaining intensified images from silver images on developed photographic films and plates. The steps involve converting silver of the developed film or plate to a radioactive compound by treatment with an aqueous alkaline solution of an organo-S35 compound; placing the treated film or plate in direct contact with a receiver film which is then exposed by radiation from the activated film; and developing and fixing the resulting intensified image on the receiver film.

  11. The Soft Agar Colony Formation Assay

    PubMed Central

    Borowicz, Stanley; Van Scoyk, Michelle; Avasarala, Sreedevi; Karuppusamy Rathinam, Manoj Kumar; Tauler, Jordi; Bikkavilli, Rama Kamesh; Winn, Robert A.

    2014-01-01

    Anchorage-independent growth is the ability of transformed cells to grow independently of a solid surface, and is a hallmark of carcinogenesis. The soft agar colony formation assay is a well-established method for characterizing this capability in vitro and is considered to be one of the most stringent tests for malignant transformation in cells. This assay also allows for semi-quantitative evaluation of this capability in response to various treatment conditions. Here, we will demonstrate the soft agar colony formation assay using a murine lung carcinoma cell line, CMT167, to demonstrate the tumor suppressive effects of two members of the Wnt signaling pathway, Wnt7A and Frizzled-9 (Fzd-9). Concurrent overexpression of Wnt7a and Fzd-9 caused an inhibition of colony formation in CMT167 cells. This shows that expression of Wnt7a ligand and its Frizzled-9 receptor is sufficient to suppress tumor growth in a murine lung carcinoma model. PMID:25408172

  12. Particle response to shock waves in solids: dynamic witness plate/PIV method for detonations

    NASA Astrophysics Data System (ADS)

    Murphy, Michael J.; Adrian, Ronald J.

    2007-08-01

    Studies using transparent, polymeric witness plates consisting of polydimethlysiloxane (PDMS) have been conducted to measure the output of exploding bridge wire (EBW) detonators and exploding foil initiators (EFI). Polymeric witness plates are utilized to alleviate particle response issues that arise in gaseous flow fields containing shock waves and to allow measurements of shock-induced material velocities to be made using particle image velocimetry (PIV). Quantitative comparisons of velocity profiles across the shock waves in air and in PDMS demonstrate the improved response achieved by the dynamic witness plate method. Schlieren photographs complement the analysis through direct visualization of detonator-induced shock waves in the witness plates.

  13. Progressive Failure Analysis of Laminated Composite Plates with Elliptical or Circular Cutout Using Finite Element Method

    NASA Astrophysics Data System (ADS)

    Lakshminarayana, A.; Vijayakumar, R.; Krishnamohana Rao, G.

    2016-09-01

    The progressive failure analysis of symmetrically laminated composite plate [0°/+45°/-45°/90°]2s with circular or elliptical cutout under uniform uniaxial compression loading is carried out using finite element method. Hashin's failure criterion is used to predict the lamina failure. A parametric study has been carried out to study the effect of elliptical / circular cutout orientation, cutout size and plate thickness on the ultimate failure load of laminated composite plate under uni-axial compression loading. It is noticed that elliptical cutout orientation has influence on the strength of the notched composite plates. It is observed that the laminate size of the elliptical/circular cutout and plate thickness has substantial influence on the ultimate failure load of notched composite plates.

  14. Spiral plate count method for the examination of raw and pasteurized milk.

    PubMed

    Donnelly, C B; Gilchrist, J E; Peeler, J T; Campbell, J E

    1976-07-01

    The spiral plate count method (SPLPC) was compared with the standard plate count (SPC) method by examining 201 samples of raw and pasteurized milk. Although the means of the two methods differed significantly at alpha = 0.01,the difference was less than 10% and was not considered to be of any practical importance. The pooled replicate variances of both methods were less than 0.003, indicating good agreement between duplicate plates, with the variance of the SPLPC slightly less than that of the SPC. We believe this study indicates that the SPLPC could be substituted for the SPC in the bacteriological examination of milk.

  15. Free in-plane vibration analysis of rectangular plates by the method of superposition

    NASA Astrophysics Data System (ADS)

    Gorman, D. J.

    2004-05-01

    The superposition method is introduced as a means for obtaining analytical-type solutions for free in-plane vibration of rectangular plates. The governing differential equations and boundary conditions are expressed in dimensionless form. The problem of free in-plane vibration of the completely free rectangular plate is resolved for illustrative purposes. Convergence is found to be rapid and excellent agreement between computed results and those obtained by previous authors utilizing the Rayleigh-Ritz energy method is obtained. It is pointed out that following procedures analogous to those utilized in resolving lateral plate vibration problems, in-plane free vibration problems related to point supported plates, plates with in-plane elastic boundary support, etc., are now amenable to solution by this method.

  16. Characterisation of structure-borne sound source using reception plate method.

    PubMed

    Putra, A; Saari, N F; Bakri, H; Ramlan, R; Dan, R M

    2013-01-01

    A laboratory-based experiment procedure of reception plate method for structure-borne sound source characterisation is reported in this paper. The method uses the assumption that the input power from the source installed on the plate is equal to the power dissipated by the plate. In this experiment, rectangular plates having high and low mobility relative to that of the source were used as the reception plates and a small electric fan motor was acting as the structure-borne source. The data representing the source characteristics, namely, the free velocity and the source mobility, were obtained and compared with those from direct measurement. Assumptions and constraints employing this method are discussed. PMID:24324380

  17. Improvement of Karmali agar by addition of polymyxin B for the detection of Campylobacter jejuni and C. coli in whole-chicken carcass rinse.

    PubMed

    Chon, Jung-Whan; Kim, Hyunsook; Yim, Jin-Hyeok; Song, Kwang-Young; Moon, Jin-San; Kim, Young-Jo; Seo, Kun-Ho

    2013-05-01

    The Karmali agar was modified by supplementation with a high concentration of polymyxin B. The goal of the study was to evaluate the effect of a high concentration of polymyxin B on the ability and selectivity of the modified Karmali agar to isolate Campylobacter jejuni and Campylobacter coli from whole chicken carcass rinse. A total of 80 whole chickens were rinsed with 400 mL of buffer peptone water. The rinsed samples were incubated with 2× blood-free modified Bolton enrichment broth for 48 h, and then streaked onto unmodified Karmali agar and modified Karmali agar supplemented with 100000 IU/L polymixin B (P-Karmali agar). The suspected colonies were finally confirmed by colony PCR. The P-Karmali agar exhibited a significantly better (P < 0.05) isolation rate than the unmodified Karmali agar (P-Karmali agar, 73.8%; unmodified Karmali agar, 33.8%). Moreover, the selectivity of the P-Karmali agar was also better (P < 0.05) than that of the other selective agar when comparing the number of contaminated plates (P-Karmali agar, 68.8%; unmodified Karmali agar, 87.5%) and growth index of competing flora (P-Karmali agar, 1.4; unmodified Karmali agar, 2.7). The improved selective agar excluded competing flora resistant to antibiotic agents in unmodified Karmali agar, increasing isolation rate and selectivity for C. jejuni and C. coli.

  18. Blood agar and Mycobacterium tuberculosis: the end of a dogma.

    PubMed

    Drancourt, M; Carrieri, P; Gévaudan, M-J; Raoult, D

    2003-04-01

    Incidental blood agar-based recovery of Mycobacterium tuberculosis led us to further investigate this routine medium for primary isolation and culture of M. tuberculosis. Fifteen respiratory tract and eight lymph node Ziehl-Neelsen-positive specimens were inoculated in parallel into tubes containing egg-based medium and 5% sheep blood agar. Colonies appeared sooner on this medium than on the egg-based medium, but this difference was not significant (P = 0.11, analysis of variance [ANOVA] test). Further experiments compared the growth of 38 respiratory and lymph node M. tuberculosis isolates when subcultured on the two media. After 6 days of incubation, 21 of 38 isolates had grown on blood agar, and the mean number of colonies was significantly greater on blood agar than on the egg-based medium (P < 0 0.001, ANOVA test). These results demonstrate that M. tuberculosis grows easily on blood agar within 1to 2 weeks, indicating that this basic medium is suitable for laboratory diagnosis of tuberculosis in addition to other media. Laboratories that routinely use prolonged incubations of blood plates, for example, for the recovery of Bartonella species, should consider the potential safety implications of encountering this highly infectious pathogen.

  19. Chemical plating method of preparing radiation source material

    DOEpatents

    Smith, P.K.; Huntoon, R.T.; Mosley, W.C. Jr.

    1973-12-11

    A uniform dispersion of a radioisotope within a noble metal matrix is provided by chemically plating a noble metal coating onto particles including a dissociable compound of the mdioisotope. A suspension of the dissociable compound in a chemically reductive solution is prepared and noble metal cations added to produce the noble metal coatings. The coated particles are filtered, dried and heated to calcine the dissociable compound to a refractory powder. The powder can be encapsulated in measured portions or consolidated and shaped into an elongated form for easy apportionnnent as radiation source material. (Official Gazette)

  20. A comparison between orthogonal and parallel plating methods for distal humerus fractures: a prospective randomized trial.

    PubMed

    Lee, Sang Ki; Kim, Kap Jung; Park, Kyung Hoon; Choy, Won Sik

    2014-10-01

    With the continuing improvements in implants for distal humerus fractures, it is expected that newer types of plates, which are anatomically precontoured, thinner and less irritating to soft tissue, would have comparable outcomes when used in a clinical study. The purpose of this study was to compare the clinical and radiographic outcomes in patients with distal humerus fractures who were treated with orthogonal and parallel plating methods using precontoured distal humerus plates. Sixty-seven patients with a mean age of 55.4 years (range 22-90 years) were included in this prospective study. The subjects were randomly assigned to receive 1 of 2 treatments: orthogonal or parallel plating. The following results were assessed: operating time, time to fracture union, presence of a step or gap at the articular margin, varus-valgus angulation, functional recovery, and complications. No intergroup differences were observed based on radiological and clinical results between the groups. In our practice, no significant differences were found between the orthogonal and parallel plating methods in terms of clinical outcomes, mean operation time, union time, or complication rates. There were no cases of fracture nonunion in either group; heterotrophic ossification was found 3 patients in orthogonal plating group and 2 patients in parallel plating group. In our practice, no significant differences were found between the orthogonal and parallel plating methods in terms of clinical outcomes or complication rates. However, orthogonal plating method may be preferred in cases of coronal shear fractures, where posterior to anterior fixation may provide additional stability to the intraarticular fractures. Additionally, parallel plating method may be the preferred technique used for fractures that occur at the most distal end of the humerus.

  1. A Novel Separation Method of Microthrix parvicella Filaments from Activated Sludge by a Hydrophobic Plate.

    PubMed

    Fei, Xuening; Li, Songya; Cao, Lingyun; Yan, Weiguo; Ma, Huaji; Jia, Guozhi

    2015-10-01

    The aim of this paper is to develop a novel method to separate Microthrix parvicella (M. parvicella) filaments from activated sludge easily and quickly, as there are a few difficulties in the isolation of M. parvicella filaments, such as complicated isolation process, time consuming, etc. In this work, a series of hydrophobic plate with and without microchannels have been prepared for the separation of M. parvicella filaments. The results showed that the presence of microchannels and hydrophobic property of the hydrophobic plates affected the separation efficiency of M. parvicella significantly. The scanning electron microscope and Keyence Digital Microscope analysis results showed that the diameter of microchannels was similar to the width of M. parvicella filament, which was beneficial for the fastening of M. parvicella filaments on the plate. The hydrophobic property of the prepared plates was tested by contact angle of water droplets, and the results displayed that the polydimethylsiloxane (PDMS) plate possessed the highest contact angle compared with that of other plates, like polymethylmethacrylate, polystyrene plate, and PDMS plate with no hydrophobic microchannels. Thus, it was concluded that the high separation efficiency of PDMS plates to M. parvicella filaments was due to its best hydrophobic property.

  2. a Comparative Study of Vibrating Loaded Plates Between the Rayleigh-Ritz and Experimental Methods

    NASA Astrophysics Data System (ADS)

    Low, K. H.; Chai, G. B.; Tan, G. S.

    1997-01-01

    Natural frequencies of rectangular plates carrying a concentrated mass are obtained by employing a set of trigonometric beam functions in the Rayleigh-Ritz method. Two models of the energy method using one-term and 100-term model are used in the study. Results obtained from the analytical study using the energy method are compared with those measured experimentally. It is found that the 100-term analytical model can generally predict well the experimental frequencies of a plate carrying an arbitrarily placed concentrated mass, whereas the one-term analytical model is only good for estimating the first-mode frequency of a plate carrying a centrally placed mass.

  3. [Evaluation of a new medium, eggplant (Solanum melongena) agar as a screening medium for Cryptococcus neoformans in environmental samples].

    PubMed

    Sengul, Mustafa; Ergin, Cağrı; Kartal, Tuğba

    2014-04-01

    .neoformans colony forming unit (cfu) per plate were found as 51, 57 and 48 (median values) on simplified Staib agar, Pal's agar and eggplant agar, respectively, while tobacco agar has lower performance with 33 cfu/petri. No statistically significant difference were found between simplified Staib agar, Pal's agar and eggplant agar's performances for C.neoformans isolations from the nature (p=0.71). In conclusion, easily prepared eggplant agar is as functional as widely used media such as simplified Staib agar and Pal's agar for the isolation of C.neoformans from the natural environment. PMID:24819266

  4. [Evaluation of a new medium, eggplant (Solanum melongena) agar as a screening medium for Cryptococcus neoformans in environmental samples].

    PubMed

    Sengul, Mustafa; Ergin, Cağrı; Kartal, Tuğba

    2014-04-01

    .neoformans colony forming unit (cfu) per plate were found as 51, 57 and 48 (median values) on simplified Staib agar, Pal's agar and eggplant agar, respectively, while tobacco agar has lower performance with 33 cfu/petri. No statistically significant difference were found between simplified Staib agar, Pal's agar and eggplant agar's performances for C.neoformans isolations from the nature (p=0.71). In conclusion, easily prepared eggplant agar is as functional as widely used media such as simplified Staib agar and Pal's agar for the isolation of C.neoformans from the natural environment.

  5. Cell-on-hydrogel platform made of agar and alginate for rapid, low-cost, multidimensional test of antimicrobial susceptibility.

    PubMed

    Sun, Han; Liu, Zhengzhi; Hu, Chong; Ren, Kangning

    2016-08-01

    Antimicrobial resistance (AMR) is a rapidly increasing threat to the effective treatment of infectious diseases worldwide. The two major remedies include: (1) using narrow-spectrum antibiotics based on rapid diagnosis; and (2) developing new antibiotics. A key part of both remedies is the antimicrobial susceptibility test (AST). However, the current standard ASTs that monitor colony formation are costly and time-consuming and the new strategies proposed are not yet practical to be implemented. Herein, we report a strategy to fabricate whole-hydrogel microfluidic chips using alginate-doped agar. This agar-based microfabrication makes it possible to prepare inexpensive hydrogel devices, and allows a seamless link between microfluidics and conventional agar-based cell culture. Different from common microfluidic systems, in our system the cells are cultured on top of the device, similar to normal agar plate culture; on the other hand, the microfluidic channels inside the hydrogel allow precise generation of linear gradient of drugs, thus giving a better performance than the conventional disk diffusion method. Cells in this system are not exposed to any shear flow, which allows the reliable tracking of individual cells and AST results to be obtained within 2-3 hours. Furthermore, our system could test the synergistic effect of drugs through two-dimensional gradient generation. Finally, the platform could be directly implemented to new drug discovery and other applications wherein a fast, cost-efficient method for studying the response of microorganisms upon drug administration is desirable. PMID:27452345

  6. Agar-Block Microcosms for Controlled Plant Tissue Decomposition by Aerobic Fungi

    PubMed Central

    Schilling, Jonathan S.

    2011-01-01

    The two principal methods for studying fungal biodegradation of lignocellulosic plant tissues were developed for wood preservative testing (soil-block; agar-block). It is well-accepted that soil-block microcosms yield higher decay rates, fewer moisture issues, lower variability among studies, and higher thresholds of preservative toxicity. Soil-block testing is thus the more utilized technique and has been standardized by American Society for Testing and Materials (ASTM) (method D 1413-07). The soil-block design has drawbacks, however, using locally-variable soil sources and in limiting the control of nutrients external (exogenous) to the decaying tissues. These drawbacks have emerged as a problem in applying this method to other, increasingly popular research aims. These modern aims include degrading lignocellulosics for bioenergy research, testing bioremediation of co-metabolized toxics, evaluating oxidative mechanisms, and tracking translocated elements along hyphal networks. Soil-blocks do not lend enough control in these applications. A refined agar-block approach is necessary. Here, we use the brown rot wood-degrading fungus Serpula lacrymans to degrade wood in agar-block microcosms, using deep Petri dishes with low-calcium agar. We test the role of exogenous gypsum on decay in a time-series, to demonstrate the utility and expected variability. Blocks from a single board rip (longitudinal cut) are conditioned, weighed, autoclaved, and introduced aseptically atop plastic mesh. Fungal inoculations are at each block face, with exogenous gypsum added at interfaces. Harvests are aseptic until the final destructive harvest. These microcosms are designed to avoid block contact with agar or Petri dish walls. Condensation is minimized during plate pours and during incubation. Finally, inoculum/gypsum/wood spacing is minimized but without allowing contact. These less technical aspects of agar-block design are also the most common causes of failure and the key source of

  7. Isolation Method (direct plating or enrichment) does not affect Antimicrobial Susceptibility of Campylobacter from Chicken Carcasses

    Technology Transfer Automated Retrieval System (TEKTRAN)

    To determine if Campylobacter isolation method influenced antimicrobial susceptibility results, the minimum inhibitory concentrations (MIC) of nine antimicrobials were compared for 291 pairs of Campylobacter isolates recovered from chicken carcass rinse samples using direct plating and an enrichment...

  8. Theoretical-experimental method of determining the drag coefficient of a harmonically oscillating thin plate

    NASA Astrophysics Data System (ADS)

    Egorov, A. G.; Kamalutdinov, A. M.; Paimushin, V. N.; Firsov, V. A.

    2016-03-01

    A method for determining the drag coefficient of a thin plate harmonically oscillating in a viscous incompressible fluid is proposed. The method is based on measuring the amplitude of deflections of cantilever-fixed thin plates exhibiting damping flexural oscillations with a frequency corresponding to the first mode and on solving an inverse problem of calculating the drag coefficient on the basis of the experimentally found logarithmic decrement of beam oscillations.

  9. Orbiter Cold Plate Intergranular Corrosion: Development of NDE Standards and Assessment of NDE Methods

    NASA Technical Reports Server (NTRS)

    Smith, Stephen W.; Winfree, William P.; Piascik, Robert S.

    2002-01-01

    During pre-servicing of a space shuttle (orbiter vehicle, OV-102), helium leak detection of an avionics cold plate identified a leak located in the face sheet oriented towards the support shelf. Subsequent destructive examination of the leaking cold plate revealed that intergranular corrosion had penetrated the 0.017-inch thick aluminum (AA6061) face sheet. The intergranular attack (IGA) was likely caused by an aggressive crevice environment created by condensation of water vapor between the cold plate and support shelf. Face sheet susceptibility to IGA is a result of the brazing process used in the fabrication of the cold plates. Cold plate components were brazed at 1000 F followed by a slow cooling process to avoid distortion of the bonded cold plate. The slow cool process caused excessive grain boundary precipitation resulting in a material that is susceptible to IGA. The objectives of this work are as follows: (1) Develop first-of-a-kind nondestructive evaluation (NDE) standards that contain IGA identical to that found in the orbiter cold plates; and (2) Assess advanced NDE techniques for corrosion detection and recommend methods for cold plate examination. This report documents the results of work performed at Langley Research Center to fulfill these objectives.

  10. A double layer plaque assay using spread plate technique for enumeration of bacteriophage MS2.

    PubMed

    Cormier, Jiemin; Janes, Marlene

    2014-02-01

    Bacteriophage MS2 is used widely as a model organism to estimate pathogenic virus survival in various environments, and is usually quantified by plaque assay. Although current plaque assays work well in enumeration of MS2 in environmental samples, quantification of MS2 calls for better visibility and higher consistency. In an attempt to improve the visibility and consistency of the current plaque assay, spread plate technique was introduced, instead of the pour plate technique used commonly in existing methods. Other parameters that influence the outcome of the plaque assay were also compared. Using spread plate technique resulted in an increase of plaque size by approximately 50% and contributed to a better visibility. Addition of supplements (glucose, CaCl2 and thiamine); reduction of agar thickness and hardness, also contributed to enhanced plaque visibility and increased plaque count. Among all the conditions tested, a supplemented thin bottom agar (10ml 1% agar) and a supplemented thin top agar (10ml 0.45% agar) with spread plate technique gave the maximum countable plaques with a minimum standard deviation. When compared to other methods, it produced significantly higher plaque count and lower variation. The optimized plaque assay significantly improved visibility and consistency of the existing plaque assay methods and could be used in quantification of MS2.

  11. Transient vibration analysis of a completely free plate using modes obtained by Gorman's superposition method

    NASA Astrophysics Data System (ADS)

    Mochida, Y.; Ilanko, S.

    2010-05-01

    This paper shows that the transient response of a plate undergoing flexural vibration can be calculated accurately and efficiently using the natural frequencies and modes obtained from the superposition method. The response of a completely free plate is used to demonstrate this. The case considered is one where all supports of a simply supported thin rectangular plate under self weight are suddenly removed. The resulting motion consists of a combination of the natural modes of a completely free plate. The modal superposition method is used for determining the transient response, and the natural frequencies and mode shapes of the plates used are obtained by Gorman's superposition method. These are compared with corresponding results based on the modes using the Rayleigh-Ritz method using the ordinary and degenerated free-free beam functions. There is an excellent agreement between the results from both approaches but the superposition method has shown faster convergence and the results may serve as benchmarks for the transient response of completely free plates.

  12. Method and apparatus for actively controlling a micro-scale flexural plate wave device

    DOEpatents

    Dohner, Jeffrey L.

    2001-01-01

    An actively controlled flexural plate wave device provides a micro-scale pump. A method of actively controlling a flexural plate wave device produces traveling waves in the device by coordinating the interaction of a magnetic field with actively controlled currents. An actively-controlled flexural plate wave device can be placed in a fluid channel and adapted for use as a micro-scale fluid pump to cool or drive micro-scale systems, for example, micro-chips, micro-electrical-mechanical devices, micro-fluid circuits, or micro-scale chemical analysis devices.

  13. Isolation of Shiga toxin-producing Escherichia coli from fresh produce using STEC heart infusion washed blood agar with mitomycin-C.

    PubMed

    Lin, Andrew; Nguyen, Lam; Clotilde, Laurie M; Kase, Julie A; Son, Insook; Lauzon, Carol R

    2012-11-01

    The ability to detect and isolate Shiga toxin-producing Escherichia coli (STEC) remains a major challenge for food microbiologists. Although methods based on nucleic acids and antibodies have improved detection of STECs in foods, isolation of these bacteria remains arduous. STEC isolation is necessary for matching food, environmental, and clinical isolates during outbreak investigations and for distinguishing between pathogenic and nonpathogenic organisms. STEC heart infusion washed blood agar with mitomycin-C (SHIBAM) is a modification of washed sheep blood agar prepared by adding mitomycin-C and optimizing both the washed blood and base agar to better isolate STECs. Most STEC isolates produce a zone of hemolysis on SHIBAM plates and are easily distinguishable from background microbiota. Here, we present data supporting the use of SHIBAM to isolate STECs from fresh produce. SHIBAM was tested for accuracy in identifying STECs (365 of 410 STEC strains were hemolytic, and 63 of 73 E. coli strains that did not produce Shiga toxin were not hemolytic) and for recovery from artificially inoculated fresh produce (11 of 24 romaine lettuce samples and 6 of 24 tomato samples). STEC recovery with SHIBAM agar was greatly improved when compared with recovery on Levine's eosin-methylene blue agar as a reference method.

  14. New method and uncertainty estimation for plate dimensions and surface measurements

    NASA Astrophysics Data System (ADS)

    Ali, Salah H. R.; Buajarern, Jariya

    2014-03-01

    Dimensional and surface quality for tile plate manufacturing control is facing difficult engineering challenges. One of these challenges being that plates in large-scale mass production contain geometrically uneven surfaces. There is a traditional measurement method used to assess the tile plate dimensions and surface quality based on standard specifications: ISO-10545-2: 1995, EOS-3168-2: 2007 and TIS 2398-2:2008. A new measurement method of the dimensions and surface quality for ceramic oblong large-scale tile plate has been developed compared to the traditional method. The strategy of the proposed method is based on CMM straightness measurement strategy instead of the centre point in the traditional method. Expanded uncertainties budgets in the measurements of each method have been estimated in detail. The capability of accurate estimations of real actual results of centre of curvature (CC), centre of edge (CE), warpage (W) and edge crack defects parameters has been achieved according to standards. Moreover, the obtained results showed not only a more accurate method but also improved the quality of tile plate products significantly.

  15. As a bacterial culture medium, citrated sheep blood agar is a practical alternative to citrated human blood agar in laboratories of developing countries.

    PubMed

    Russell, F M; Biribo, S S N; Selvaraj, G; Oppedisano, F; Warren, S; Seduadua, A; Mulholland, E K; Carapetis, J R

    2006-09-01

    Human blood agar (HuBA) is widely used in developing countries for the isolation of bacteria from clinical specimens. This study compared citrated sheep blood agar (CSBA) and HuBA with defibrinated horse blood agar and defibrinated sheep blood agar (DSBA) for the isolation and antibiotic susceptibility testing of reference and clinical strains of Streptococcus pneumoniae, Streptococcus pyogenes, and Staphylococcus aureus. Reference and clinical strains of all organisms were diluted in brain heart infusion and a clinical specimen of cerebrospinal fluid and cultured on all agars. Viable counts, colony morphology, and colony size were recorded. Susceptibility testing for S. pneumoniae and S. pyogenes was performed on defibrinated sheep blood Mueller-Hinton agar, citrated sheep blood Mueller-Hinton agar (CSB MHA), and human blood Mueller-Hinton agar plates. For all organisms, the colony numbers were similar on all agars. Substantially smaller colony sizes and absent or minimal hemolysis were noted on HuBA for all organisms. Antibiotic susceptibility results for S. pneumoniae were similar for the two sheep blood agars; however, larger zone sizes were displayed on HuBA, and quality control for the reference strain failed on HuBA. For S. pyogenes, larger zone sizes were demonstrated on HuBA and CSBA than on DSBA. Poor hemolysis made interpretation of the zone sizes difficult on HuBA. CSBA is an acceptable alternative for the isolation of these organisms. The characteristic morphology is not evident, and hemolysis is poor on HuBA; and so HuBA is not recommended for use for the isolation or the susceptibility testing of any of these organisms. CSB MHA may be suitable for use for the susceptibility testing of S. pneumoniae.

  16. Electrochemical Device Comprising Composite Bipolar Plate and Method of Using the Same

    NASA Technical Reports Server (NTRS)

    Mittelsteadt, Cortney K. (Inventor); Braff, William A. (Inventor)

    2013-01-01

    An electrochemical device and methods of using the same. In one embodiment, the electrochemical device may be used as a fuel cell and/or as an electrolyzer and includes a membrane electrode assembly (MEA), an anodic gas diffusion medium in contact with the anode of the MEA, a cathodic gas diffusion medium in contact with the cathode, a first bipolar plate in contact with the anodic gas diffusion medium, and a second bipolar plate in contact with the cathodic gas diffusion medium. Each of the bipolar plates includes an electrically-conductive, chemically-inert, non-porous, liquid-permeable, substantially gas-impermeable membrane in contact with its respective gas diffusion medium, as well as a fluid chamber and a non-porous an electrically-conductive plate.

  17. Practical method of diffusion-welding steel plate in air

    NASA Technical Reports Server (NTRS)

    Holko, K. H.; Moore, T. J.

    1971-01-01

    Method is ideal for critical service requirements where parent metal properties are equaled in notch toughness, stress rupture and other characteristics. Welding technique variations may be used on a variety of materials, such as carbon steels, alloy steels, stainless steels, ceramics, and reactive and refractory materials.

  18. Verification of 235U mass content in nuclear fuel plates by an absolute method

    NASA Astrophysics Data System (ADS)

    El-Gammal, W.

    2007-01-01

    Nuclear Safeguards is referred to a verification System by which a State can control all nuclear materials (NM) and nuclear activities under its authority. An effective and efficient Safeguards System must include a system of measurements with capabilities sufficient to verify such NM. Measurements of NM using absolute methods could eliminate the dependency on NM Standards, which are necessary for other relative or semi-absolute methods. In this work, an absolute method has been investigated to verify the 235U mass content in nuclear fuel plates of Material Testing Reactor (MTR) type. The most intense gamma-ray signature at 185.7 keV emitted after α-decay of the 235U nuclei was employed in the method. The measuring system (an HPGe-spectrometer) was mathematically calibrated for efficiency using the general Monte Carlo transport code MCNP-4B. The calibration results and the measured net count rate were used to estimate the 235U mass content in fuel plates at different detector-to-fuel plate distances. Two sets of fuel plates, containing natural and low enriched uranium, were measured at the Fuel Fabrication Facility. Average accuracies for the estimated 235U masses of about 2.62% and 0.3% are obtained for the fuel plates containing natural and low enriched uranium; respectively, with a precision of about 3%.

  19. An approximate method for sonic fatigue analysis of plates and shells

    NASA Astrophysics Data System (ADS)

    Blevins, R. D.

    1989-02-01

    Approximate analytical methods are developed for determining the response of plate and shell structures to coherent sound fields. The methods are based on separating the spatial and temporal aspects of the problem and then developing approximations for both. Direct comparison is made with experimental data.

  20. Phase Velocity Method for Guided Wave Measurements in Composite Plates

    NASA Astrophysics Data System (ADS)

    Moreno, E.; Galarza, N.; Rubio, B.; Otero, J. A.

    Carbon Fiber Reinforced Polymer is a well-recognized material for aeronautic applications. Its plane structure has been widely used where anisotropic characteristics should be evaluated with flaw detection. A phase velocity method of ultrasonic guided waves based on a pitch-catch configuration is presented for this purpose. Both shear vertical (SV) and shear horizontal (SH) have been studied. For SV (Lamb waves) the measurements were done at different frequencies in order to evaluate the geometrical dispersion and elastic constants. The results for SV are discussed with an orthotropic elastic model. Finally experiments with lamination flaws are presented.

  1. 3-D vibration analysis of annular sector plates using the Chebyshev-Ritz method

    NASA Astrophysics Data System (ADS)

    Zhou, D.; Lo, S. H.; Cheung, Y. K.

    2009-02-01

    The three-dimensional free vibration of annular sector plates with various boundary conditions is studied by means of the Chebyshev-Ritz method. The analysis is based on the three-dimensional small strain linear elasticity theory. The product of Chebyshev polynomials satisfying the necessary boundary conditions is selected as admissible functions in such a way that the governing eigenvalue equation can be conveniently derived through an optimization process by the Ritz method. The boundary functions guarantee the satisfaction of the geometric boundary conditions of the plates and the Chebyshev polynomials provide the robustness for numerical calculation. The present study provides a full vibration spectrum for the thick annular sector plates, which cannot be given by the two-dimensional (2-D) theories such as the Mindlin theory. Comprehensive numerical results with high accuracy are systematically produced, which can be used as benchmark to evaluate other numerical methods. The effect of radius ratio, thickness ratio and sector angle on natural frequencies of the plates with a sector angle from 120° to 360° is discussed in detail. The three-dimensional vibration solutions for plates with a re-entrant sector angle (larger than 180°) and shallow helicoidal shells (sector angle larger than 360°) with a small helix angle are presented for the first time.

  2. Automatic Digital Plate Reading for Surveillance Cultures.

    PubMed

    Kirn, Thomas J

    2016-10-01

    The automation of specimen processing and culture workup has rapidly emerged in clinical microbiology laboratories throughout the world and more recently in the United States. While many U.S. laboratories have implemented some form of automated specimen processing and some have begun performing digital plate reading, automated colony analysis is just beginning to be utilized clinically. In this issue of the Journal of Clinical Microbiology, M. L. Faron et al. (J Clin Microbiol 54:2470-2475, 2016, http://dx.doi.org/10.1128/JCM.01040-16) report the results of their evaluation of the performance of the WASPLab Chromogenic Detection Module (CDM) for categorizing chromogenic agar plates as negative or "nonnegative" for vancomycin-resistant enterococci (VRE). Their major finding was 100% sensitivity for detection of "nonnegative" specimens using CDM compared to manual methods for specimens plated on two different types of VRE chromogenic agar plates. Additionally, utilization of digital plate reading in conjunction with automated colony analysis was predicted to result in significant savings based on greatly reduced labor costs.

  3. An extended field method solution for a pulse loaded thin plate

    NASA Technical Reports Server (NTRS)

    Donaldson, B. K.; Starkey, N. B.

    1980-01-01

    This paper deals with a new extension of a weighted residual method of analysis called the extended field method. The extended field method is applied for the first time to the problem of the transient vibration of a uniformly thin elastic plate. Numerical results have been obtained which validate the analysis procedure and show better solution convergence than is obtainable by standard methods of analysis for the same number of degrees of freedom. Further studies are necessary to obtain still better convergence.

  4. The dynamic flexibility method in structural dynamics: Application to nonuniform beams and plates and to cavity-backed plates

    NASA Astrophysics Data System (ADS)

    Lee, Jinkyo

    1993-01-01

    Efficient and accurate analytical or semi-analytical solutions have been developed for the dynamics of one and two dimensional linear structures employing elemental dynamic flexibility formulation. This dissertation is divided into three parts. In the first, the elemental flexibility formulation is developed for Euler-Bernoulli beams having discontinuous section properties, which can be viewed as the synthesis of uniform beams, and the exactness of the solution is established. In the second, the elemental flexibility formulation is extended to thin rectangular plates having Levy boundary conditions, and conditions under which the exact solution can be achieved are presented. In the third, the structural-acoustic problem of Helmholtz fluid enclosed by a partially flexible cavity is posed and solved. Here, a concise analytical representation of the structural dynamics is used in conjunction with a boundary element approach for the fluid medium to give an efficient and accurate semi-analytical solution. All three sections are organized along similar lines. Following an introduction and review of the pertinent literature, the governing equations are derived and solved, a series of example problems is presented, the results from the examples are compared with similar results from the literature, and efficacy of the method when compared with other methods is discussed. This is followed by a general conclusions section and a series of appendices.

  5. A variable-order laminated plate theory based on the variational-asymptotical method

    NASA Technical Reports Server (NTRS)

    Lee, Bok W.; Sutyrin, Vladislav G.; Hodges, Dewey H.

    1993-01-01

    The variational-asymptotical method is a mathematical technique by which the three-dimensional analysis of laminated plate deformation can be split into a linear, one-dimensional, through-the-thickness analysis and a nonlinear, two-dimensional, plate analysis. The elastic constants used in the plate analysis are obtained from the through-the-thickness analysis, along with approximate, closed-form three-dimensional distributions of displacement, strain, and stress. In this paper, a theory based on this technique is developed which is capable of approximating three-dimensional elasticity to any accuracy desired. The asymptotical method allows for the approximation of the through-the-thickness behavior in terms of the eigenfunctions of a certain Sturm-Liouville problem associated with the thickness coordinate. These eigenfunctions contain all the necessary information about the nonhomogeneities along the thickness coordinate of the plate and thus possess the appropriate discontinuities in the derivatives of displacement. The theory is presented in this paper along with numerical results for the eigenfunctions of various laminated plates.

  6. Validating the plate mapping method: Comparing drawn foods and actual foods of university students in a cafeteria.

    PubMed

    Sharp, David E

    2016-05-01

    To examine effects of plate size on meals, I developed a method I label plate mapping. To validate plate mapping, a quasi-experimental between participants study was conducted that asked university students to accurately draw their lunch meal. Participants were randomized into groups where they were asked either pre-consumption or post-consumption to draw their lunch on either a 9″ or 11″ paper plate. Coding plate drawings for total meal size revealed that students drew bigger meals on larger plates and participant meal size drawings were more accurate when the plate provided was the same size as the meal plate used. Gender moderated meal size drawings, with women generally drawing meals that were more highly correlated and similarly sized to actual meals when compared to the drawings of men. Overall, the size of plate drawings was highly correlated with the size of actual foods, which provides support for the validity of the method of plate mapping. These findings suggest that plate mapping can be applied to estimate meal size and assess sensitivity to plate size. Gaining a better understanding of the mechanisms and processes that influence food consumption habits can help increase awareness of these cues for both academics as well as for consumers of food and benefit short- and long-term health goals. PMID:26896836

  7. IDENTIFICATION OF SALMONELLA-POSITIVE FECAL SAMPLES USING A 96-WELL MICROCULTURE PLATE TECHNIQUE (RX METHOD)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Conventional Salmonella isolation involves multiple sample transfers to culture media performed by an experienced microbiologist. The Reaction (RX) Plate method, a modification of the RX tube designed by Gailey et al. (2004), consolidates pre-enrichment (buffered peptone water or GN Hajna), enrichm...

  8. IDENTIFICATION OF SALMONELLA-POSITIVE FECAL SAMPLES USING A 96-WELL MICROCULTURE PLATE TECHNIQUE (RX METHOD)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Conventional Salmonella isolation involves multiple sample transfers to culture media performed by an experienced microbiologist. The modified semi-solid RV and XLT (RX) Plate method, a modification of the RX tube format designed by Gailey et al. (2004), consolidates pre-enrichment (buffered pepton...

  9. Method for preparing surfaces of metal composites having a brittle phase for plating. [Patent application

    DOEpatents

    Coates, C.W.; Wilson, T.J.

    1982-05-19

    The present invention is directed to a method for preparing surfaces of two-phase metal composites having relatively brittle and malleable components for plating with corrosion-resistant material. In practice of the present invention, the surfaces of the composite are etched to remove a major portion or fraction of the brittle component. The etched surface is then peened with particulates for breaking the brittle component from the surfaces and for spreading or smearing the malleable component over the surfaces. The peened surface is then chemically cleaned of residual traces of the brittle component to which the corrosion-resistant material may be plated thereon in an adherent manner.

  10. Voltage oxide removal for plating: A new method of electroplating oxide coated metals in situ

    SciTech Connect

    Gutfeld, R. J. von; West, A. C.

    2007-03-15

    A novel in situ method for electroplating oxide coated metals is described. Termed VORP, for voltage oxide removal for plating, the process utilizes a voltage pulse {approx}20-200 V, {approx}2 ms in duration, applied between working and counterelectrodes while both are immersed in a copper electrolyte. The pulse is almost immediately followed by galvanostatic plate-up. Adherent copper deposits up to {approx}4 {mu}m in height on stainless steel 316 coupons have been obtained. Temperature testing up to 260 deg. C in air does not affect the copper adhesion. A preliminary model for oxide removal is proposed utilizing concepts of dielectric breakdown.

  11. Second-order two-scale method for bending behaviors of composite plate with periodic configuration

    NASA Astrophysics Data System (ADS)

    Zhu, Guoqing; Cui, Junzhi

    2010-06-01

    In this paper, the second-order two-scale analysis method for bending behaviors of the plate made from composites with 3-D periodic configuration is presented by means of construction way. It can capture the microscopic 3-D mechanics behaviors caused from 3-D micro-structures. First, directly starting from the 3-D elastic plate model of composite materials with 3-D periodic configuration, three cell models are defined, and correspondingly the three classes of cell functions only defined on 3 normalized cells are constructed. And then, the effective homogenization parameters of composites are calculated from those local functions, it leads to a 2-D homogenized laminar plate problem. Next, to solve it the homogenization solution is obtained. Finally, the second-order two-scale solution is constructed from the micro-cell functions and the homogenization solution.

  12. Second-Order Two-Scale Method for Bending Behaviors of Composite Plate with Periodic Configuration

    NASA Astrophysics Data System (ADS)

    Zhu, Guoqing; Cui, Junzhi

    2010-05-01

    In this paper, the second-order two-scale analysis method for bending behaviors of the plate made from composites with 3-D periodic configuration is presented by means of construction way. It can capture the microscopic 3-D mechanics behaviors caused from 3-D micro-structures. First, directly starting from the 3-D elastic plate model of composite materials with 3-D periodic configuration, three cell models are defined, and correspondingly the three classes of cell functions only defined on 3 normalized cells are constructed. And then, the effective homogenization parameters of composites are calculated from those local functions, it leads to a 2-D homogenized laminar plate problem. Next, to solve it the homogenization solution is obtained. Finally, the second-order two-scale solution is constructed from the micro-cell functions and the homogenization solution.

  13. Identification of spatially correlated excitations on a bending plate using the Virtual Fields Method

    NASA Astrophysics Data System (ADS)

    Berry, Alain; Robin, Olivier

    2016-08-01

    This paper aims at identifying the autospectral density and spatial correlation functions of random excitations acting on the surface of a thin plate, from its measured vibration response. The general framework is the Virtual Fields Method (VFM), which was previously applied by the authors to the identification of deterministic excitations on plates. In the present paper, the VFM framework is extended to the case of spatially correlated excitations. It is shown that extraction of the loading power spectral density requires measuring power spectral density functions of transverse displacements and bending curvatures, which can be typically derived from contactless Laser Doppler Vibrometry measurements. The paper details the implementation of the VFM for random excitations, presents numerical simulations and experimental results for diffuse acoustic field excitation of a plate.

  14. Agar polysaccharides from Gracilaria species (Rhodophyta, Gracilariaceae).

    PubMed

    Marinho-Soriano, E

    2001-07-26

    Yield, physical and chemical properties of agar from three agarophytes species (Gracilaria gracilis, G. dura and G. bursa-pastoris) were determined. The agar yield from the three species varied significantly (P<0.01). The highest yields of agar (34.8%) and the lowest (30%) were obtained from G. bursa-pastoris and G. gracilis, respectively. Highest gel strength (630+/-15 g cm(-2)) was obtained from agar extracted from G. gracilis and lowest from G. bursa-pastoris (26+/-3.6 g cm(-2)). The values of 3,6-anhydrogalactose were similar for G. gracilis and G. dura and there were no significant differences among the species. The sulfate contents varied significantly (P<0.01) and the higher value was obtained from G. bursa-pastoris. Among the three species, G. gracilis showed superior agar quality than the other two species, hence it can be considered a good potential source for industrial use.

  15. Plate measurement techniques and reduction methods used by the West German satellite observers, and resulting consequences for the observation

    NASA Technical Reports Server (NTRS)

    Deker, H.

    1971-01-01

    The West German tracking stations are equipped with ballistic cameras. Plate measurement and plate reduction must therefore follow photogrammetric methods. Approximately 100 star positions and 200 satellite positions are measured on each plate. The mathematical model for spatial rotation of the bundle of rays is extended by including terms for distortion and internal orientation of the camera as well as by providing terms for refraction which are computed for the measured coordinates of the star positions on the plate. From the measuring accuracy of the plate coordinates it follows that the timing accuracy for the exposures has to be about one millisecond, in order to obtain a homogeneous system.

  16. Modification of Karmali agar by supplementation with potassium clavulanate for the isolation of Campylobacter from chicken carcass rinses.

    PubMed

    Chon, Jung-Whan; Kim, Hong-Seok; Kim, Dong-Hyeon; Kim, Hyunsook; Choi, In-Soo; Oh, Deog-Hwan; Seo, Kun-Ho

    2014-07-01

    The detection ability and selectivity of Karmali agar was improved by supplementation of an extended-spectrum β-lactamase inhibitor, potassium clavulanate. The optimum concentration of potassium clavulanate (0.5 μg/ml) in Karmali agar was determined by inoculation of 50 Campylobacter and 30 extended-spectrum β-lactamase-producing E. coli strains onto normal and modified Karmali agar containing various concentrations of the agent. Eighty retail carcasses were rinsed with 400 ml of buffered peptone water. The rinse samples were enriched in 2 × blood-free Bolton enrichment broth at 42°C for 48 h and then were streaked onto normal and modified Karmali agar containing 0.5 μg/ml potassium clavulanate. The suspicious colonies were subcultured on Columbia blood agar and confirmed by colony PCR. In chicken carcass samples, the modified Karmali agar showed a significantly greater isolation rate than normal Karmali agar (42.5 versus 21.3%; P < 0.05). Furthermore, the selectivity of the modified Karmali agar was also significantly higher (P < 0.05) than that of the normal Karmali agar, as seen by comparison of the number of contaminated agar plates (83.8 versus 97.5%) and the growth index (1.67 versus 2.91) of the non-Campylobacter colonies.

  17. Dynamic buckling analysis of delaminated composite plates using semi-analytical finite strip method

    NASA Astrophysics Data System (ADS)

    Ovesy, H. R.; Totounferoush, A.; Ghannadpour, S. A. M.

    2015-05-01

    The delamination phenomena can become of paramount importance when the design of the composite plates is concerned. In the current study, the effect of through-the-width delamination on dynamic buckling behavior of a composite plate is studied by implementing semi-analytical finite strip method. In this method, the energy and work integrations are computed analytically due to the implementation of trigonometric functions. Moreover, the method can lead to converged results with comparatively small number of degrees of freedom. These features have made the method quite efficient. To account for delamination effects, displacement field is enriched by adding appropriate terms. Also, the penetration of the delamination surfaces is prevented by incorporating an appropriate contact scheme into the time response analysis. Some selected results are validated against those available in the literature.

  18. Comparison of Exoelectrogenic Bacteria Detected Using Two Different Methods: U-tube Microbial Fuel Cell and Plating Method

    PubMed Central

    Yu, Jaecheul; Cho, Sunja; Kim, Sunah; Cho, Haein; Lee, Taeho

    2012-01-01

    In a microbial fuel cell (MFC), exoelectrogens, which transfer electrons to the electrode, have been regarded as a key factor for electricity generation. In this study, U-tube MFC and plating methods were used to isolate exoelectrogens from the anode of an MFC. Disparate microorganisms were identified depending on isolation methods, despite the use of an identical source. Denaturing gel gradient electrophoresis (DGGE) analysis showed that certain microorganisms became dominant in the U-tube MFC. The predominant bacterium was similar to Ochrobactrum sp., belonging to the Alphaproteobacteria, which was shown to be able to function as an exoelectrogen in a previous study. Three isolates, one affiliated with Bacillus sp. and two with Paenibacillus sp., were identified using the plating method, which belonged to the Gram-positive bacteria, the Firmicutes. The U-tube MFCs were inoculated with the three isolates using the plating method, operated in the batch mode and the current was monitored. All of the U-tube MFCs inoculated with each isolate after isolation from plates produced lower current (peak current density: 3.6–16.3 mA/m2) than those in U-tube MFCs with mixed culture (48.3–62.6 mA/m2). Although the isolates produced low currents, various bacterial groups were found to be involved in current production. PMID:22129603

  19. Free vibration analysis of functionally graded plates using the element-free kp-Ritz method

    NASA Astrophysics Data System (ADS)

    Zhao, X.; Lee, Y. Y.; Liew, K. M.

    2009-01-01

    A free vibration analysis of metal and ceramic functionally graded plates that uses the element-free kp-Ritz method is presented. The material properties of the plates are assumed to vary continuously through their thickness according to a power-law distribution of the volume fractions of the plate constituents. The first-order shear deformation plate theory is employed to account for the transverse shear strain and rotary inertia, and mesh-free kernel particle functions are used to approximate the two-dimensional displacement fields. The eigen-equation is obtained by applying the Ritz procedure to the energy functional of the system. Convergence studies are performed to examine the stability of the proposed method, and comparisons of the solutions derived with those reported in the literature are provided to verify its accuracy. Four types of functionally graded rectangular and skew plates—Al/Al 2O 3, Al/ZrO 2, Ti-6Al-4V/Aluminum oxide, and SUS304/Si 3N 4—are included in the study, and the effects of the volume fraction, boundary conditions, and length-to-thickness ratio on their frequency characteristics are discussed in detail.

  20. Methods for thermochemical convection in Earth's mantle with force-balanced plates

    NASA Astrophysics Data System (ADS)

    Brandenburg, J. P.; van Keken, P. E.

    2007-11-01

    Models of convection in the mantle can be used to study the effects of differentiation and remixing on the geochemical evolution of the Earth. Implementation of melting and degassing at mid-ocean ridges and subduction zones requires an adequate approximation of plate tectonics as well as temperature-dependent rheology. We have developed a new two-dimensional cylindrical model that combines a force-balance method for energetically consistent stiff plates with tracer-discretized chemical buoyancy. Basaltic crust is extracted at distinct spreading centers and is subducted into the lower mantle. We find that the unmodified implementation of the force-balance equations in a full cylinder causes occasional spurious rotations by amplification of numerical discretization errors. The method is stable if a single internal symmetry boundary condition is used, but this causes artificial pooling of dense crust near the boundary where it is easily disrupted. This results in artificially enhanced remixing of dense crust. We modify the force-balance equations to damp net lateral plate movement. The energetic consistency of this modification is then demonstrated by comparison to a one-plate, single convection cell calculation. With the removal of the symmetry boundary condition a more continuous rate of crustal pooling is observed. This suggests that models with symmetry boundary conditions may overpredict the rate of pooling and remixing of ancient crust.

  1. Buckling analysis of moderately thick rectangular plates using coupled displacement field method

    NASA Astrophysics Data System (ADS)

    Meera Saheb, K.; Aruna, K.

    2015-12-01

    A simple and efficient coupled displacement field method is developed to study the buckling load parameters of the moderately thick rectangular plates. This method has been successfully applied to study the same for the Timoshenko beams. A single term trigonometric admissible displacement field is assumed for one of the variables, say, the total rotations (in both X, Y directions). Making use of the coupling equations, the spatial variation for the remaining lateral displacement field is derived in terms of the total rotations. The coupled displacement field method makes the energy formulation to contains half the number of unknown independent coefficients, in the case of a rectangular plate, contrary to the conventional Rayleigh-Ritz method. The expressions for the non-dimensional buckling load parameters of the moderately thick rectangular plates with all the edges simply supported are derived. The numerical values of these parameters obtained using the coupled displacement field method match very well with open literature demonstrating the effectiveness of the coupled displacement field method.

  2. Waves on Thin Plates: A New (Energy Based) Method on Localization

    NASA Astrophysics Data System (ADS)

    Turkaya, Semih; Toussaint, Renaud; Kvalheim Eriksen, Fredrik; Lengliné, Olivier; Daniel, Guillaume; Grude Flekkøy, Eirik; Jørgen Måløy, Knut

    2016-04-01

    Noisy acoustic signal localization is a difficult problem having a wide range of application. We propose a new localization method applicable for thin plates which is based on energy amplitude attenuation and inversed source amplitude comparison. This inversion is tested on synthetic data using a direct model of Lamb wave propagation and on experimental dataset (recorded with 4 Brüel & Kjær Type 4374 miniature piezoelectric shock accelerometers, 1 - 26 kHz frequency range). We compare the performance of this technique with classical source localization algorithms, arrival time localization, time reversal localization, localization based on energy amplitude. The experimental setup consist of a glass / plexiglass plate having dimensions of 80 cm x 40 cm x 1 cm equipped with four accelerometers and an acquisition card. Signals are generated using a steel, glass or polyamide ball (having different sizes) quasi perpendicular hit (from a height of 2-3 cm) on the plate. Signals are captured by sensors placed on the plate on different locations. We measure and compare the accuracy of these techniques as function of sampling rate, dynamic range, array geometry, signal to noise ratio and computational time. We show that this new technique, which is very versatile, works better than conventional techniques over a range of sampling rates 8 kHz - 1 MHz. It is possible to have a decent resolution (3cm mean error) using a very cheap equipment set. The numerical simulations allow us to track the contributions of different error sources in different methods. The effect of the reflections is also included in our simulation by using the imaginary sources outside the plate boundaries. This proposed method can easily be extended for applications in three dimensional environments, to monitor industrial activities (e.g boreholes drilling/production activities) or natural brittle systems (e.g earthquakes, volcanoes, avalanches).

  3. Subculture on potato dextrose agar as a complement to the broth microdilution assay for Malassezia pachydermatis.

    PubMed

    Prado, Marilena R; Brito, Erika H S; Brilhante, Raimunda S N; Cordeiro, Rossana A; Leite, João J G; Sidrim, José J C; Rocha, Marcos F G

    2008-10-01

    The main aim of this study was to verify the efficacy of subculture on potato dextrose agar (PDA) as a complement to the in vitro susceptibility test for Malassezia pachydermatis strains by a broth microdilution method, as well as to determine the MIC and MFC of azole derivatives, amphotericin B and caspofungin. The microdilution assay was performed in 96-well plates using a modified RPMI 1640 medium. The M. pachydermatis strains were resistant to caspofungin. All strains (n=50) had shown MIC values of <0.03, <0.03, 2.0, 4.0 and 4.0 microg/ml for itraconazole, ketoconazole, voriconazole, fluconazole and amphotericin B, respectively. Thus, the subculture on PDA improved the analysis of the in vitro antifungal susceptibility of M. pachydermatis.

  4. Weld Bead Distortion of Thin-Plate Using Weak Digital Image Correlation Method

    NASA Astrophysics Data System (ADS)

    Guo, Nan; Yin, Xianqing; Liang, Jin; Ma, Ninshu

    2016-09-01

    Currently, the primary method used to investigate weld bead distortions is based on finite element prediction. However, in this paper, we proposed a three-dimensional optical method based on weak digital image correlation technology to track the dynamic distortion of the weld bead throughout the welding and cooling process. An experimental investigation demonstrated that the weld bead zone was distorted into a dish shape during the welding process and changed into a saddle shape after cooling down. In the weld bead, the out-of-plate distortion was significantly larger than the in-plate distortion, and the longitudinal plastic strain distribution was small and uniform, whereas the transverse strain was larger. This optical experimental method could be useful in the validation of numerical models in the welding process and important to research on welding distortions.

  5. Method and apparatus for acoustic plate mode liquid-solid phase transition detection

    DOEpatents

    Blair, Dianna S.; Freye, Gregory C.; Hughes, Robert C.; Martin, Stephen J.; Ricco, Antonio J.

    1993-01-01

    A method and apparatus for sensing a liquid-solid phase transition event is provided which comprises an acoustic plate mode detecting element placed in contact with a liquid or solid material which generates a high-frequency acoustic wave that is attenuated to an extent based on the physical state of the material is contact with the detecting element. The attenuation caused by the material in contact with the acoustic plate mode detecting element is used to determine the physical state of the material being detected. The method and device are particularly suited for detecting conditions such as the icing and deicing of wings of an aircraft. In another aspect of the present invention, a method is provided wherein the adhesion of a solid material to the detecting element can be measured using the apparatus of the invention.

  6. Growth kinetics of three species of Tetrahymena on solid agar

    SciTech Connect

    Dobra, K.W.; McArdle, E.W.; Ehret, C.F.

    1980-01-01

    A nutrient-agar method without liquid overlay has been developed for cultivation of ciliates. Three species of Tetrahymena-T. pyriformis strain W, T. rostrata strain UNI, and T. vorax strain V/sub 2/S, representing the 3 main groups of Tetrahymena species, were used; however the method should apply to other ciliates. Growth on the surface of the agar was facilitated by an optimal surface-to-volume ratio yielding a high density of ciliates and short generation times. At the highest density achieved, the cells became irregularly hexagonal and formed a monolayer tissue on the agar. Ciliates grown on agar were like those in liquid culture, typical oral ciliature, food-vacuole formation, and typical cortical patterns being retained. Advantages of this method include high cell density, easy recovery, and optimal O/sub 2/ supply. The organisms can also be cultivated on the surface of sterile cellulose-nitrate filters, facilitating in situ fixation and staining as well as transfer into different media by transfer of filters with cells, without prior centrifugation and resuspension.

  7. Mechanical touch responses of Arabidopsis TCH1-3 mutant roots on inclined hard-agar surface

    NASA Astrophysics Data System (ADS)

    Zha, Guodong; Wang, Bochu; Liu, Junyu; Yan, Jie; Zhu, Liqing; Yang, Xingyan

    2016-01-01

    The gravity-induced mechanical touch stimulus can affect plant root architecture. Mechanical touch responses of plant roots are an important aspect of plant root growth and development. Previous studies have reported that Arabidopsis TCH1-3 genes are involved in mechano-related events, how-ever, the physiological functions of TCH1-3 genes in Arabidopsis root mechanoresponses remain unclear. In the present study, we applied an inclined hard agar plate method to produce mechanical touch stimulus, and provided evidence that altered mechanical environment could influence root growth. Furthermore, tch1-3 Arabidopsis mutants were investigated on inclined agar surfaces to explore the functions of TCH1-3 genes on Arabidopsis root mechanoresponses. The results showed that two tch2 mutants, cml24-2 and cml24-4, exhibited significantly reduced root length, biased skewing, and decreased density of lateral root. In addition, primary root length and density of lateral root of tch3 (cml12-2) was significantly decreased on inclined agar surfaces. This study indicates that the tch2 and tch3 mutants are hypersensitive to mechanical touch stimulus, and TCH2 (CML24-2 and CML24-4) and TCH3 (CML12-2) genes may participate in the mechanical touch response of Arabidopsis roots.

  8. An interlaboratory study on efficient detection of Shiga toxin-producing Escherichia coli O26, O103, O111, O121, O145, and O157 in food using real-time PCR assay and chromogenic agar.

    PubMed

    Hara-Kudo, Yukiko; Konishi, Noriko; Ohtsuka, Kayoko; Iwabuchi, Kaori; Kikuchi, Rie; Isobe, Junko; Yamazaki, Takumiko; Suzuki, Fumie; Nagai, Yuhki; Yamada, Hiroko; Tanouchi, Atsuko; Mori, Tetsuya; Nakagawa, Hiroshi; Ueda, Yasufumi; Terajima, Jun

    2016-08-01

    To establish an efficient detection method for Shiga toxin (Stx)-producing Escherichia coli (STEC) O26, O103, O111, O121, O145, and O157 in food, an interlaboratory study using all the serogroups of detection targets was firstly conducted. We employed a series of tests including enrichment, real-time PCR assays, and concentration by immunomagnetic separation, followed by plating onto selective agar media (IMS-plating methods). This study was particularly focused on the efficiencies of real-time PCR assays in detecting stx and O-antigen genes of the six serogroups and of IMS-plating methods onto selective agar media including chromogenic agar. Ground beef and radish sprouts samples were inoculated with the six STEC serogroups either at 4-6CFU/25g (low levels) or at 22-29CFU/25g (high levels). The sensitivity of stx detection in ground beef at both levels of inoculation with all six STEC serogroups was 100%. The sensitivity of stx detection was also 100% in radish sprouts at high levels of inoculation with all six STEC serogroups, and 66.7%-91.7% at low levels of inoculation. The sensitivity of detection of O-antigen genes was 100% in both ground beef and radish sprouts at high inoculation levels, while at low inoculation levels, it was 95.8%-100% in ground beef and 66.7%-91.7% in radish sprouts. The sensitivity of detection with IMS-plating was either the same or lower than those of the real-time PCR assays targeting stx and O-antigen genes. The relationship between the results of IMS-plating methods and Ct values of real-time PCR assays were firstly analyzed in detail. Ct values in most samples that tested negative in the IMS-plating method were higher than the maximum Ct values in samples that tested positive in the IMS-plating method. This study indicates that all six STEC serogroups in food contaminated with more than 29CFU/25g were detected by real-time PCR assays targeting stx and O-antigen genes and IMS-plating onto selective agar media. Therefore, screening

  9. Key techniques and applications of adaptive growth method for stiffener layout design of plates and shells

    NASA Astrophysics Data System (ADS)

    Ding, Xiaohong; Ji, Xuerong; Ma, Man; Hou, Jianyun

    2013-11-01

    The application of the adaptive growth method is limited because several key techniques during the design process need manual intervention of designers. Key techniques of the method including the ground structure construction and seed selection are studied, so as to make it possible to improve the effectiveness and applicability of the adaptive growth method in stiffener layout design optimization of plates and shells. Three schemes of ground structures, which are comprised by different shell elements and beam elements, are proposed. It is found that the main stiffener layouts resulted from different ground structures are almost the same, but the ground structure comprised by 8-nodes shell elements and both 3-nodes and 2-nodes beam elements can result in clearest stiffener layout, and has good adaptability and low computational cost. An automatic seed selection approach is proposed, which is based on such selection rules that the seeds should be positioned on where the structural strain energy is great for the minimum compliance problem, and satisfy the dispersancy requirement. The adaptive growth method with the suggested key techniques is integrated into an ANSYS-based program, which provides a design tool for the stiffener layout design optimization of plates and shells. Typical design examples, including plate and shell structures to achieve minimum compliance and maximum bulking stability are illustrated. In addition, as a practical mechanical structural design example, the stiffener layout of an inlet structure for a large-scale electrostatic precipitator is also demonstrated. The design results show that the adaptive growth method integrated with the suggested key techniques can effectively and flexibly deal with stiffener layout design problem for plates and shells with complex geometrical shape and loading conditions to achieve various design objectives, thus it provides a new solution method for engineering structural topology design optimization.

  10. A sensitive and simple plaque formation method for the Stx2 phage of Escherichia coli O157:H7, which does not form plaques in the standard plating procedure.

    PubMed

    Islam, Md Rakibul; Ogura, Yoshitoshi; Asadulghani, Md; Ooka, Tadasuke; Murase, Kazunori; Gotoh, Yasuhiro; Hayashi, Tetsuya

    2012-05-01

    Bacteriophages are fascinating genetic elements that play key roles in the evolution and diversification of bacterial genomes. Shiga toxin (Stx)-transducing phages are important genetic elements that disseminate the stx genes among enterohemorrhagic Escherichia coli (EHEC). They are generally regarded as lambda-like phages, but their biological and genetic properties have not been fully elucidated. This is partly due to a serious obstacle in obtaining visible plaques. Here, we describe a modified double agar overlay method that allows us to easily detect and accurately enumerate plaques of Sp5, the Stx2 phage of the EHEC O157 Sakai strain, which otherwise does not produce plaques in the standard plating procedure. In the modified method, the top agar was supplemented with mitomycin C (MMC) and Ca(2+) (or Mg(2+)). MMC appears to prevent the lysogenization of Sp5 and/or compel Sp5 to follow the lytic cycle by inducing the SOS response in the host cells. The divalent cations significantly improve phage adsorption to the host cells and thus yield a synergistic effect in combination with MMC. We further applied this method to a receptor analysis of Sp5 and obtained findings that suggest that the YaeT (BamA) protein serves as the receptor of Sp5. This method would be a very useful tool in studies of Stx2 phages and studies of other phages from various bacteria, in which researchers often encounter problems with plaque formation.

  11. Feasibility study on welding and cutting methods for thick plate in fusion reactor

    SciTech Connect

    Osaki, T.; Nakayama, Y.; Kobayashi, T.

    1995-12-31

    Application of tungsten-arc inert-gas (TIG) welding with narrow gap has been considered as a hopeful joint method to suppress post welding deformation for thick plates. The authors studied some parameters to predict the post-welding deformation for the narrow gap shape of TIG welding. As for cutting methods, the water jet method was applied for weld joints in this study. Reweld tests by using the TIG welding method were successfully performed under the condition of cutting surface as it was. Results of tensile tests for reweld joints showed no reduction in strength. This reveals a good prospect of providing reweld groove surface without any machining on site.

  12. Crack Imaging and Quantification in Aluminum Plates with Guided Wave Wavenumber Analysis Methods

    NASA Technical Reports Server (NTRS)

    Yu, Lingyu; Tian, Zhenhua; Leckey, Cara A. C.

    2015-01-01

    Guided wavefield analysis methods for detection and quantification of crack damage in an aluminum plate are presented in this paper. New wavenumber components created by abrupt wave changes at the structural discontinuity are identified in the frequency-wavenumber spectra. It is shown that the new wavenumbers can be used to detect and characterize the crack dimensions. Two imaging based approaches, filter reconstructed imaging and spatial wavenumber imaging, are used to demonstrate how the cracks can be evaluated with wavenumber analysis. The filter reconstructed imaging is shown to be a rapid method to map the plate and any existing damage, but with less precision in estimating crack dimensions; while the spatial wavenumber imaging provides an intensity image of spatial wavenumber values with enhanced resolution of crack dimensions. These techniques are applied to simulated wavefield data, and the simulation based studies show that spatial wavenumber imaging method is able to distinguish cracks of different severities. Laboratory experimental validation is performed for a single crack case to confirm the methods' capabilities for imaging cracks in plates.

  13. Validation of a two-plate microbiological method for screening antibiotic residues in shrimp tissue.

    PubMed

    Dang, Pham Kim; Degand, Guy; Danyi, Sophie; Pierret, Gilles; Delahaut, Philippe; Ton, Vu Dinh; Maghuin-Rogister, Guy; Scippo, Marie-Louise

    2010-07-01

    Microbiological inhibition screening tests could play an important role to detect residues of antibiotics in the different animal food products, but very few are available for the aquaculture products in general, and for shrimps in particular. A two-plate microbiological method to screen shrimp for residues of the most commonly used antibiotics has been developed and validated according to criteria derived from the European Commission Decision 2002/657/CE. Bacillus subtilis was used as a sensitive strain to target antibiotics. Culture conditions on Petri plates (pH of medium) were selected to enhance the capacity of antibiotic detection. Antibiotic residues were extracted from shrimps using acetonitrile/acetone (70/30, v/v) before application on Petri plates seeded with B. subtilis. The method was validated using spiked blank tissues as well as antibiotic treated shrimps with enrofloxacin and tetracycline, two antibiotics often found to be used in shrimp production. For tetracyclines and (fluoro)quinolones, the detection capability was below the maximum residue limit (MRL), while it was around the MRL for sulfonamides. The specificity of the microbiological screening was 100% in all cases while the sensitivity and accuracy was 100% in almost all cases. The capacity of the method to detect contaminated samples was confirmed on antibiotic treated shrimps, analyzed in parallel with a confirmatory method (Liquid Chromatography coupled to mass spectrometry (LC-MS)).

  14. Improved method for detection of glycosidases in bacterial colonies.

    PubMed Central

    Paoni, N F; Arroyo, R L

    1984-01-01

    An assay has been developed to detect bacterial glycosidases in colonies grown on the surface of agar plates. Advantages of this technique over previously described methods include elimination of the need for replica plating, better visualization of chromagenic reaction products, and a simple permeabilization step to enable better penetration by chromagenic substrates. Images PMID:6364970

  15. Probabilistic fracture investigation of symmetric angle ply laminated composite plates using displacement correlation method

    NASA Astrophysics Data System (ADS)

    Lal, Achchhe; Palekar Shailesh, P.

    2016-01-01

    The second order statistics of mixed mode stress intensity factors (MSIF) of single edge V-notched angle ply laminated composite plate subjected to uniaxial tensile load with uncertinity in the system properties using displacement correlation method (DCM) is evaluated. The random system properties such as material properties, crack opening and crack length are modelled as combined uncorrelated and correlated random system variables. A C0 finite element method (FEM) based on higher order shear deformation plate theory (HSDT) is used for basic formulation. The Taylor series based first order perturbation technique (FOPT), second order perturbation technique (SOPT) are used and direct Monte Carlo simulation (MCS) is performed to evaluate the statistics (mean and coefficient of variance) of the mixed mode SIFs. The present work signifies the accurate analysis of frature behaviour by influence of different random variables and fibre orientations on the fracture behaviour in angle ply laminates.

  16. Developments in variational methods for high performance plate and shell elements

    NASA Technical Reports Server (NTRS)

    Felippa, Carlos A.; Militello, Carmelo

    1991-01-01

    High performance elements are simple finite elements constructed to deliver engineering accuracy with coarse arbitrary grids. This is part of a series on the variational foundations of high-performance elements, with emphasis on plate and shell elements constructed with the free formulation (FF) and assumed natural strain (ANS) methods. Parameterized variational principles are studied that provide a common foundation for the FF and ANS methods, as well as for a combination of both. From this unified formulation a variant of the ANS formulation, called the assumed natural deviatoric strain (ANDES) formulation, emerges as an important special case. The first ANDES element, a high-performance 9 degrees of freedom triangular Kirchhoff plate bending element, is briefly described to illustrate the use of the new formulation.

  17. Some Experiments With Agar-Grown Seedlings

    ERIC Educational Resources Information Center

    Freeland, P. W.

    1973-01-01

    Two percent agar gel is reported as a better medium for germination and growth studies. Students can be encouraged to undertake many simple experiments and make precise observations by using this medium. (PS)

  18. Characterization of physicochemical properties of carboxymethyl agar.

    PubMed

    Cao, Mingzhao; Liu, Xin; Luan, Jimei; Zhang, Xiaodong

    2014-10-13

    A series of carboxymethyl agars (CMAs) with different degree of substitution (DS) were prepared, and their properties were determined and analyzed. The results showed that with the increase of DS, the dissolving temperature, the gelling temperature, the gel melting temperature, the gel strength, the gel hardness, the gel fracturability, and the solution apparent viscosity of CMA all decreased, except that its gel cohesiveness and gel springiness increased. The variation process of agar molecules in solution from coil to helix could be observed by measuring the optical rotation of the solution at such a low concentration, at which even the solution could not form a gel. The gel skeleton microstructures of both agar and CMA were of porous network structure, and the pore size of CMA became smaller and denser with the increase of its DS. After carboxymethylation, the agar hygroscopicity was improved, but its thermal stability was lowered.

  19. Draft Genome Sequence of the Novel Agar-Digesting Marine Bacterium HQM9▿

    PubMed Central

    Du, Zongjun; Zhang, Zhewen; Miao, Tingting; Wu, Jiayan; Lü, Guoqiang; Yu, Jun; Xiao, Jingfa; Chen, Guanjun

    2011-01-01

    Strain HQM9, an aerobic, rod-shaped marine bacterium from red algae, can produce agarases and liquefy solid plating media efficiently when agar is used as a coagulant. Here we report the draft genome sequence and the initial findings from a preliminary analysis of strain HQM9, which should be a novel species of Flavobacteriaceae. PMID:21725015

  20. A new medium for determining the total plate count in food.

    PubMed

    Smith, C F; Townsend, D E

    1999-12-01

    SimPlate for Total Plate Count-Color Indicator (TPC-CI, IDEXX Laboratories, Inc., Westbrook, Me.) is a new medium that incorporates the redox dye resazurin to detect and quantify bacteria in food. Enumeration is achieved by the most probable number method using a SimPlate device. Viable bacteria are detected in each well of the SimPlate device by the biochemical reduction of resazurin, which is blue, to the pink resorufin or the clear dihydroresorufin indicators. Results after 24 h of incubation for TPC-CI are highly correlated with standard plate count agar after 48 h of incubation. Correlation coefficients from studies conducted at five laboratories ranged from 0.94 to 0.98 in side-by-side comparisons against standard plate count agar. Four additional test sites, using alternative methods for determining the aerobic plate count in food, reported similar results in comparison studies (r = 0.91 to 0.97). The slopes from linear regression analysis at all sites ranged from 0.91 to 0.98, with y intercepts ranging from 0.11 to 0.84. Samples used for the validation of TPC-CI included raw food products (i.e., liver and grains), which may contain natural enzymes that interfere with enzyme-based detection methods. No interference was seen from the foods tested. These results suggest that TPC-CI is a suitable alternative to existing plate count methods and has reduced incubation time.

  1. Differentiation of Candida dubliniensis from Candida albicans on rosemary extract agar and oregano extract agar.

    PubMed

    de Loreto, Erico Silva; Pozzatti, Patrícia; Alves Scheid, Liliane; Santurio, Deise; Morais Santurio, Janio; Alves, Sydney Hartz

    2008-01-01

    Candida dubliniensis is a recently described pathogenic species which shares many phenotypic features with Candida albicans and therefore, may be misidentified in microbiological laboratories. Because molecular methods can be onerous and unfeasible in routine mycological laboratories with restricted budgets such as those in developing countries, phenotypic techniques have been encouraged in the development of differential media for the presumptive identification of these species. We examined the colony morphology and chlamydospore production of 30 C. dubliniensis isolates and 100 C. albicans isolates on two new proposed media: rosemary (Rosmarinus officinalis) extract agar (REA) and oregano (Origanum vulgare) extract agar (OEA). These substrates are traditionally used as spices and medicinal herbs. In both of these media, all C. dubliniensis isolates (100%) showed rough colonies with peripheral hyphal fringes and abundant chlamydospores after 24 to 48 hr of incubation at 25 degrees C. In contrast, under the same conditions, all isolates of C. albicans (100%) showed smooth colonies without hyphal fringes or chlamydospores. In conclusion, REA and OEA offer a simple, rapid, and inexpensive screening media for the differentiation of C. albicans and C. dubliniensis.

  2. Agar composition affects in vitro screening of biocontrol activity of antagonistic microorganisms.

    PubMed

    Bosmans, L; De Bruijn, I; De Mot, R; Rediers, H; Lievens, B

    2016-08-01

    Agar-based screening assays are the method of choice when evaluating antagonistic potential of bacterial biocontrol-candidates against pathogens. We showed that when using the same medium, but different agar compositions, the activity of a bacterial antagonist against Agrobacterium was strongly affected. Consequently, results from in vitro screenings should be interpreted cautiously. PMID:27166668

  3. Comparative detection of bacterial adhesion to Caco-2 cells with ELISA, radioactivity and plate count methods.

    PubMed

    Le Blay, Gwenaëlle; Fliss, Ismaïl; Lacroix, Christophe

    2004-11-01

    Different methods are used to study bacterial adhesion to intestinal epithelial cells, which is an important step in pathogenic infection as well as in probiotic colonization of the intestinal tract. The aim of this study was to compare the ELISA-based method with more conventional plate count and radiolabeling methods for bacterial adhesion detection. An ELISA-based assay was optimized for the detection of Bifidobacterium longum and Escherichia coli O157:H7, which are low and highly adherent bacteria, respectively. In agreement with previous investigations, a percentage of adhesion below 1% was obtained for B. longum with ELISA. However, high nonspecific background and low positive signals were measured due to the use of polyclonal antibodies and the low adhesion capacity with this strain. In contrast, the ELISA-based method developed for E. coli adhesion detected a high adhesion percentage (15%). For this bacterium the three methods tested gave similar results for the highest bacterial concentrations (6.8 Log CFU added bacteria/well). However, differences among methods increased with the addition of decreased bacterial concentration due to different detection thresholds (5.9, 5.6 and 2.9 Log CFU adherent bacteria/well for radioactivity, ELISA and plate count methods, respectively). The ELISA-based method was shown to be a good predictor for bacterial adhesion compared to the radiolabeling method when good quality specific antibodies were used. This technique is convenient and allows handling of numerous samples.

  4. A novel Direct MIC-gradient Strip Method to screen for antibiotic-resistant faecal Enterobacteriaceae.

    PubMed

    Gammelsrud, Karianne Wiger; Knudsen, Per Kristian; Høiby, E Arne

    2016-10-01

    A novel method to detect resistant faecal Enterobacteriaceae was developed by applying MIC-gradient strips directly onto agar plates inoculated with faeces. The method provided the susceptibility pattern (MICs) of the dominant bacterial population directly on the plates and also detected smaller resistant subpopulations with a sensitivity of 1/10(5).

  5. Fusobacterium necrophorum- detection and identification on a selective agar.

    PubMed

    Bank, Steffen; Nielsen, Hanne Merete; Mathiasen, Boris Hoyer; Leth, Dorte Christiansen; Kristensen, Lena Hagelskjaer; Prag, Jørgen

    2010-12-01

    Within the last decade, Fusobacterium necrophorum subsp. funduliforme has been considered a clinically important pathogen causing pharyngitis especially in adolescents and young adults. F. necrophorum pharyngitis can progress into Lemierre's syndrome, which is a severe and life-threatening infection. However, throat swabs are not cultured anaerobically in the routine and even if cultured anaerobically, it can be difficult to identify F. necrophorum from the normal flora of the throat. F. necrophorum is therefore often overlooked as the cause of pharyngitis. In our laboratory, a F. necrophorum selective agar has been developed containing vancomycin and nalidixin, which inhibit the growth of most Gram-positive and many Gram-negative bacteria, respectively. β-haemolysis of horse blood can be detected, which further facilitates the detection and identification of F. necrophorum. The F. necrophorum selective agar was evaluated against a quantitative real-time polymerase chain reaction assay and shown to have a significantly higher sensitivity for detecting F. necrophorum than the anaerobic agar commonly used in Denmark. Furthermore, the F. necrophorum selective agar does not require experienced laboratory technicians, require fewer subcultures, is probably less expensive and is faster to perform than other culture methods.

  6. Prescreening bacterial colonies for bioactive molecules with Janus plates, a SBS standard double-faced microbial culturing system.

    PubMed

    Sánchez-Hidalgo, Marina; Pascual, Javier; de la Cruz, Mercedes; Martín, Jesús; Kath, Gary S; Sigmund, Janet M; Masurekar, Prakash; Vicente, Francisca; Genilloud, Olga; Bills, Gerald F

    2012-08-01

    Despite the availability of many culture-based antibiotic screening methods, the lack of sensitive automated methods to identify functional molecules directly from microbial cells still limits the search for new biologically active compounds. The effectiveness of antibiotic detection is influenced by the solubility of the assayed compounds, indicator strain sensitivity, culture media and assay configuration. We describe a qualitative high throughput screening system for detecting cell-perturbing molecules from bacterial colonies employing two opposed agar layers sequentially formed in prototype Society for Biomolecular Screening (SBS) plates, named Janus plates. Direct assay of microbial colonies against target organisms in opposed agar layers overcomes some of the limitations of agar overlay methods. The system enables the rapid detection of extracellular cell-perturbing molecules, e.g., antibiotics, excreted directly from environmental isolates. The source bacterial colonies remain separate from the target organism. The growth layer is prepared and grown independently, so environmental strains can be grown for longer intervals, at temperatures and in media that favor their growth and metabolite expression, while the assay layer with pathogens, usually requiring nutrient-rich medium and elevated temperatures, are added later. Colonies to be tested can be precisely arrayed on the first agar surface, thus avoiding dispersion and disturbance of potential antibiotic-producing colonies by overlaying agar with the target strain. The rectangular SBS configuration facilitates factorial replication of dense microbial colony arrays for testing with multiple assays and assay conditions employing robotic colony pickers and pin tools. Opposed agar layers only slightly reduced the effectiveness for detecting growth inhibition from pure antibiotics compared to single-layer agar diffusion assays. The Janus plate enabled an automation-assisted workflow where a lone operator can

  7. Laminar Convective Boundary Layer Slip Flow over a Flat Plate using Homotopy Analysis Method

    NASA Astrophysics Data System (ADS)

    Daniel, Yahaya Shagaiya

    2016-08-01

    In the present study, the influence of velocity slip and suction at the boundary on the steady laminar convective boundary layer flow over a flat plate with convective boundary condition is analyzed. Similarity transformation is used to transform the boundary layer equations which are coupled with partial differential equations into system of ordinary differential equations, which are then solved semi-analytically by homotopy analysis method. The results obtained are presented for several values of the physical governing parameter and comparison with the results published in literature are in perfect agreement. Increase in the slip parameter increases the velocity to a point that the momentum boundary layer becomes thinner. The convective parameter increases as the plate surface temperature increases. The suction on the viscous incompressible fluid suppresses the velocity field and Prandtl number increases by decreasing the temperature and the thermal boundary layer thickness as a result of increase in fluid viscosity.

  8. Method for preparing surfaces of metal composites having a brittle phase for plating

    DOEpatents

    Coates, Cameron W.; Wilson, Thomas J.

    1984-01-01

    The present invention is directed to a method for preparing surfaces of two-phase metal composites having relatively brittle and malleable components for plating with corrosion-resistant material. In practice of the present invention, the surfaces of the composites are etched to remove a major portion or fraction of the brittle component. The etched surface is then peened with particulates for breaking the brittle component from the surfaces and for spreading or smearing the malleable component over the surfaces. The peened surface is then chemically cleaned of residual traces of the brittle component so as to provide a surface of essentially the malleable component to which the corrosion-resistant material may be plated thereon in an adherent manner.

  9. Micro-Macro Analysis of Viscoelastic Unidirectional Laminated Composite Plates Using DR Method

    NASA Astrophysics Data System (ADS)

    Falahatgar, Seyed Reza; Salehi, Manouchehr; Aghdam, Mohammad Mohammadi

    2010-10-01

    The Dynamic Relaxation (DR) technique together with finite difference discritization is used to study the bending behavior of Mindlin composite plate including geometric nonlinearity. The overall behavior of the unidirectional composite is obtained from a three-dimensional (3D) micromechanical model, in any combination of normal and shear loading conditions, based on the assumptions of Simplified Unit Cell Method (SUCM). The composite system consists of nonlinear viscoelastic matrix reinforced by transversely isotropic elastic fibers. A recursive formulation for the hereditary integral of the Schapery viscoelastic constitutive equation in multiaxial stress state is used to model the nonlinear viscoelastic matrix material in the material level. The creep tests data is used for verification of the predicted response of the current approach. Under uniform lateral pressure, the laminated plate deformation with clamped and hinged edged constraints is predicted for various time steps.

  10. Evaluation of the SimPlate method for enumeration of Escherichia coli in swab samples from beef and lamb carcasses.

    PubMed

    Hauge, Sigrun J; Nesbakken, Truls; Skjerve, Eystein; Dommarsnes, Kari; Østensvik, Øyvin

    2010-08-15

    Abattoirs have to enumerate Escherichia coli on carcass surfaces as part of compulsory HACCP monitoring and they therefore need rapid and reliable methods. The objective of this study was to compare a conventional plating method with a faster, simpler method for detection and enumeration of E. coli in samples from naturally contaminated carcasses. The two methods were the conventional pour plate method of the Nordic Committee on Food Analysis; NMKL Method No. 125, and the enzymatic method of SimPlate Coliforms &E. coli. Materials were 588 cotton-cloth samples used for swabbing 100 cm(2) areas on four sites on cattle and lamb carcasses in three commercial abattoirs in Norway. E. coli was detected by at least one of the methods in 270 (46%) of the samples. Forty-five samples (8%) were positive only by SimPlate while 28 samples (5%) were positive only by NMKL125. Cohen's kappa value was 0.74 for detection/non-detection results, which showed a high level of agreement between the two methods. E. coli counts determined by the conventional NMKL125 method showed a high concordance correlation (ccc 0.80, slope 0.99) with most probable number (MPN) values obtained with SimPlate. SimPlate is a rapid and reliable method for detection and enumeration of E. coli and a suitable alternative method for use with swab samples from cattle and lamb carcasses. PMID:20659776

  11. A microtiter-plate screening method for biofilm disinfection and removal.

    PubMed

    Pitts, Betsey; Hamilton, Martin A; Zelver, Nicholas; Stewart, Philip S

    2003-08-01

    A quantitative spectrophotometric method was developed to measure the removal and killing efficacy of antibiofilm agents. Biofilms of Pseudomonas aeruginosa or Staphylococcus epidermidis were grown in 96-well plates, treated with an agent, then stained with either the biomass indicator crystal violet or the respiratory indicator 5-cyano-2,3-ditolyl tetrazolium chloride. This rapid screening method is sensitive enough to elucidate concentration-response relationships as well as differences between species responses to treatments. Using these assays, agents can be ranked by their ability to remove or kill biofilm. PMID:12782382

  12. An analytical method for vibration of laminated composite rectangular plates having arbitrary combinations of boundary conditions

    NASA Astrophysics Data System (ADS)

    Narita, Y.

    This work presents a method of analysis for solving the free vibration of symmetrically laminated composite rectangular plates having any combination of free, simply supported and clamped edges along four sides. This approach uses a Ritz method for the energy functional, and trial functions used for deflections are introduced so as to automatically include geometric boundary conditions for a prescribed boundary. A computer code was developed to calculate natural frequencies and mode shapes for the problem, and was used to demonstrate the effectiveness and accuracy of the present approach.

  13. Measure and characterization of lameness in gestating sows using force plate, kinematic, and accelerometer methods.

    PubMed

    Conte, S; Bergeron, R; Gonyou, H; Brown, J; Rioja-Lang, F C; Connor, L; Devillers, N

    2014-12-01

    pair of legs and weight shifting are good indicators of lameness. Multivariate analysis on fore and hind legs showed independency between variables related to animals in movement (measures from kinematics) and variables related to static animals (measures from the force plate and accelerometers). Therefore, both static and dynamic methods need to be used to detect various lame sows. PMID:25403203

  14. Error compensation of thin plate-shape part with prebending method in face milling

    NASA Astrophysics Data System (ADS)

    Yi, Wei; Jiang, Zhaoliang; Shao, Weixian; Han, Xiangcheng; Liu, Wenping

    2015-01-01

    Low weight and good toughness thin plate parts are widely used in modern industry, but its flexibility seriously impacts the machinability. Plenty of studies focus on the influence of machine tool and cutting tool on the machining errors. However, few researches focus on compensating machining errors through the fixture. In order to improve the machining accuracy of thin plate-shape part in face milling, this paper presents a novel method for compensating the surface errors by prebending the workpiece during the milling process. First, a machining error prediction model using finite element method is formulated, which simplifies the contacts between the workpiece and fixture with spring constraints. Milling forces calculated by the micro-unit cutting force model are loaded on the error prediction model to predict the machining error. The error prediction results are substituted into the given formulas to obtain the prebending clamping forces and clamping positions. Consequently, the workpiece is prebent in terms of the calculated clamping forces and positions during the face milling operation to reduce the machining error. Finally, simulation and experimental tests are carried out to validate the correctness and efficiency of the proposed error compensation method. The experimental measured flatness results show that the flatness improves by approximately 30 percent through this error compensation method. The proposed method not only predicts the machining errors in face milling thin plate-shape parts but also reduces the machining errors by taking full advantage of the workpiece prebending caused by fixture, meanwhile, it provides a novel idea and theoretical basis for reducing milling errors and improving the milling accuracy.

  15. A symplectic analytical wave based method for the wave propagation and steady state forced vibration of rectangular thin plates

    NASA Astrophysics Data System (ADS)

    Ma, Yongbin; Zhang, Yahui; Kennedy, David

    2015-03-01

    A semi-analytical method is used to investigate the wave propagation characteristics and steady state forced vibration response for rectangular thin plates. By way of a rigorous but simple derivation, the governing differential equations for transverse vibration of rectangular thin plates are first converted into Hamiltonian canonical equations. Following the method of separation of variables, a symplectic eigenproblem is formed whose solution gives analytically the dispersion equation and the wave mode shape. Using the wave modes, i.e. the wave propagation parameters and wave shapes, and combining the directly excited waves, the wave propagation within the plate and the wave reflection at the boundary, the forced response of the plate can be computed in the wave domain with high precision and high efficiency. The present method is based on the basic elasticity equations of the plate, and can give the symplectic analytical solutions for the wave modes for any combination of simple boundary conditions along the plate edges. The present method eliminates the limitation of the traditional analytical wave propagation method which can only obtain wave modes for plates with two opposite edges simply supported. In contrast to numerical wave propagation methods, the present method provides symplectic analytical solutions for the wave modes, and hence the computations are of high precision and well conditioned. Also, continuously distributed external forces can be easily considered. In the numerical examples, the wave propagation characteristics are analyzed for plates with three different combinations of boundary conditions, i.e. with two opposite edges either both simply supported, or both clamped, or one simply supported and the other clamped. The steady state forced responses are also computed for plates excited by point forces, as well as for line and area distributed forces, for the three combinations of boundary conditions. Comparison of the present results with

  16. The analysis of the accuracy of the wheel alignment inspection method on the side-slip plate stand

    NASA Astrophysics Data System (ADS)

    Gajek, A.; Strzępek, P.

    2016-09-01

    The article presents the theoretical basis and the results of the examination of the wheel alignment inspection method on the slide slip plate stand. It is obligatory test during periodic technical inspection of the vehicle. The measurement is executed in the dynamic conditions. The dependence between the lateral displacement of the plate and toe-in of the tested wheels has been shown. If the diameter of the wheel rim is known then the value of the toe-in can be calculated. The comparison of the toe-in measurements on the plate stand and on the four heads device for the wheel alignment inspection has been carried out. The accuracy of the measurements and the influence of the conditions of the tests on the plate stand (the way of passing through the plate) were estimated. The conclusions about the accuracy of this method are presented.

  17. Apparatus and method for explosive bonding to edge of flyer plate

    NASA Technical Reports Server (NTRS)

    Bement, Laurence J. (Inventor); Kushnick, Anne C. (Inventor)

    1991-01-01

    The invention is an apparatus and a process for the explosive joining of a flyer plate and a base plate. The apparatus consists of a flyer plate positioned over a base plate. The flyer plate has a notch containing a filler material in intimate contact with the flyer plate. An adhesive means holds a ribbon explosive partially overlapping the notch in the flyer plate. A detonating means initiates the ribbon explosive that drives the flyer plate to accomplish a high velocity, angular collision between the mating surfaces. This collision creates surface melts and effacing bonding, resulting in electron sharing linkups between the plates. An unbonded tab fractures at a base of the notch leaving a bond to an edge of the attached flyer plate.

  18. 3M Petrifilm enterobacteriaceae count plate method for enumeration of enterobacteriaceae in selected foods: collaborative study.

    PubMed

    Silbernagel, Karen M; Lindberg, Kathryn G

    2003-01-01

    The practice of detecting and enumerating all oxidase-negative, glucose-fermenting-Gram-negative rods (i.e., the family Enterobacteriaceae) is used to indicate unsanitary or inadequate food processing conditions. The objective of this interlaboratory collaborative study was to evaluate and compare the methods described in Standard Methods for the Examination of Dairy Products (SMEDP) and the Compendium of Methods for the Microbiological Examination of Foods (Compendium) with a commercial product, the 3M Petrifilm Enterobacteriaceae Count Plate, for the recovery of Enterobacteriaceae in foods. Six foods--cheddar cheese, milk, flour, frozen prepared meals, frozen broccoli, and nut pieces--were analyzed for Enterobacteriaceae by 12 collaborating laboratories. For each food tested, the collaborators received 8 blind test portions consisting of a control test portion and 3 levels of inoculated test portion, each in duplicate. Each test portion was tested by the Petrifilm Enterobacteriaceae Count Plate method as well as the SMEDP or Compendium methods. The precision estimates (repeatability or within-laboratory variation, and reproducibility or between-laboratory variation) were calculated with standard statistical techniques.

  19. Agar agar-stabilized milled zerovalent iron particles for in situ groundwater remediation.

    PubMed

    Velimirovic, Milica; Schmid, Doris; Wagner, Stephan; Micić, Vesna; von der Kammer, Frank; Hofmann, Thilo

    2016-09-01

    Submicron-scale milled zerovalent iron (milled ZVI) particles produced by grinding macroscopic raw materials could provide a cost-effective alternative to nanoscale zerovalent iron (nZVI) particles for in situ degradation of chlorinated aliphatic hydrocarbons in groundwater. However, the aggregation and settling of bare milled ZVI particles from suspension presents a significant obstacle to their in situ application for groundwater remediation. In our investigations we reduced the rapid aggregation and settling rate of bare milled ZVI particles from suspension by stabilization with a "green" agar agar polymer. The transport potential of stabilized milled ZVI particle suspensions in a diverse array of natural heterogeneous porous media was evaluated in a series of well-controlled laboratory column experiments. The impact of agar agar on trichloroethene (TCE) removal by milled ZVI particles was assessed in laboratory-scale batch reactors. The use of agar agar significantly enhanced the transport of milled ZVI particles in all of the investigated porous media. Reactivity tests showed that the agar agar-stabilized milled ZVI particles were reactive towards TCE, but that their reactivity was an order of magnitude less than that of bare, non-stabilized milled ZVI particles. Our results suggest that milled ZVI particles could be used as an alternative to nZVI particles as their potential for emplacement into contaminated zone, their reactivity, and expected longevity are beneficial for in situ groundwater remediation.

  20. A new chromogenic agar medium for detection of potentially virulent Yersinia enterocolitica.

    PubMed

    Weagant, Stephen D

    2008-02-01

    Several outbreaks of foodborne yersiniosis have been documented and this disease continues to be source of infections transmitted through foods. The selective agars most commonly used to isolate Yersinia enterocolitica in clinical, food and environmental samples, cefsulodin-irgasan-novobiocin (CIN) and MacConkey (MAC) agars, lack the ability to differentiate potentially virulent Y. enterocolitica from other Yersinia that may be present as well as some other bacterial spp. This study proposes the use of an agar medium, Y. enterocolitica chromogenic medium (YeCM), for isolation of potentially virulent Y. enterocolitica. This agar contains cellobiose as the fermentable sugar, a chromogenic substrate and selective inhibitors for suppression of colony formation by many competing bacteria. All strains of potentially virulent Yersinia of biotypes 1B, and biotypes 2-5 formed convex, red bulls-eye colonies on YeCM that were very similar to those described for CIN agar. However, Y. enterocolitica biotype 1A and other related Yersinia formed colonies that were purple/blue on YeCM while they formed typical red bulls-eye colonies on CIN agar. When a mixture of potentially virulent Y. enterocolitica biotype 1B, Y. enterocolitica biotype 1A and 5 other bacterial species was used to artificially contaminate tofu and then spread-plated on three selective agars, Y. enterocolitica biotype 1B colonies were easily distinguished from other strains on YeCM. However, Y. enterocolitica biotype 1B colonies were indistinguishable from many other colonies on CIN and only distinguishable from those of C. freundii on MAC. When colonies were picked and identified from these agars, typical colonies from YeCM were confirmed only as Y. enterocolitica biotype 1B. Typical colonies on CIN and MAC were found to belong to several competing species and biotypes.

  1. Projection-free proper orthogonal decomposition method for a cantilever plate in supersonic flow

    NASA Astrophysics Data System (ADS)

    Xie, Dan; Xu, Min; Dowell, Earl H.

    2014-11-01

    This paper explores the use of the proper orthogonal decomposition (POD) method for supersonic nonlinear flutter of a cantilever plate or wing. The aeroelastic equations are constructed using von Karman plate theory and first-order piston theory. The two-dimensional POD modes (POMs) in xy plane are determined from the chaotic results given by the traditional Rayleigh-Ritz (RR) approach. For a specific structure, the POMs need to be calculated once and then can be used for various parameters of interest. The derivatives of the POMs are calculated numerically to avoid the complex projection from the POMs to the Rayleigh-Ritz modes (RRMs). Numerical examples demonstrate that the POD method using 4 POMs can obtain accurate limit cycle oscillation (LCO) results with substantial computational cost savings, compared with 12 RRMs by the Rayleigh-Ritz method. The POD method is employed for the analysis of the chaotic oscillations. It is also demonstrated that the POD modes are robust over a range of flight parameters.

  2. Extended layerwise method for laminated composite plates with multiple delaminations and transverse cracks

    NASA Astrophysics Data System (ADS)

    Li, D. H.; Zhang, X.; Sze, K. Y.; Liu, Y.

    2016-10-01

    In this paper, the extended layerwise method (XLWM), which was developed for laminated composite beams with multiple delaminations and transverse cracks (Li et al. in Int J Numer Methods Eng 101:407-434, 2015), is extended to laminated composite plates. The strong and weak discontinuous functions along the thickness direction are adopted to simulate multiple delaminations and interlaminar interfaces, respectively, whilst transverse cracks are modeled by the extended finite element method (XFEM). The interaction integral method and maximum circumferential tensile criterion are used to calculate the stress intensity factor (SIF) and crack growth angle, respectively. The XLWM for laminated composite plates can accurately predicts the displacement and stress fields near the crack tips and delamination fronts. The thickness distribution of SIF and thus the crack growth angles in different layers can be obtained. These information cannot be predicted by using other existing shell elements enriched by XFEM. Several numerical examples are studied to demonstrate the capabilities of the XLWM in static response analyses, SIF calculations and crack growth predictions.

  3. Extended layerwise method for laminated composite plates with multiple delaminations and transverse cracks

    NASA Astrophysics Data System (ADS)

    Li, D. H.; Zhang, X.; Sze, K. Y.; Liu, Y.

    2016-07-01

    In this paper, the extended layerwise method (XLWM), which was developed for laminated composite beams with multiple delaminations and transverse cracks (Li et al. in Int J Numer Methods Eng 101:407-434, 2015), is extended to laminated composite plates. The strong and weak discontinuous functions along the thickness direction are adopted to simulate multiple delaminations and interlaminar interfaces, respectively, whilst transverse cracks are modeled by the extended finite element method (XFEM). The interaction integral method and maximum circumferential tensile criterion are used to calculate the stress intensity factor (SIF) and crack growth angle, respectively. The XLWM for laminated composite plates can accurately predicts the displacement and stress fields near the crack tips and delamination fronts. The thickness distribution of SIF and thus the crack growth angles in different layers can be obtained. These information cannot be predicted by using other existing shell elements enriched by XFEM. Several numerical examples are studied to demonstrate the capabilities of the XLWM in static response analyses, SIF calculations and crack growth predictions.

  4. Evaluation of the OSIRIS video reader as an automated measurement system for the agar disk diffusion technique.

    PubMed

    Kolbert, M; Chegrani, F; Shah, P M

    2004-05-01

    Measurement of inhibition zones by the automated OSIRIS system was compared with manual measurement. In total, 14 176 measurements were made with 352 staphylococcal and 80 Enterobacteriaceae isolates, involving four panels of antibiotics on round and square Mueller-Hinton agar plates, according to the German DIN 58940 recommendations. Variations of +/- 3 mm in zone size measurements were defined as tolerable. Very major errors (i.e., classification of a resistant isolate as susceptible by the OSIRIS system) occurred in < 1% of tests. With staphylococci, the best concordance was recorded for rifampicin (91.3%), moxifloxacin (88.1%), and gentamicin (86.3%), while the concordance on square plates for vancomycin, pristinamycin and kanamycin was 97.2%, 96.1% and 96.0%, respectively. The poorest concordance was for cefuroxime (43.7%) and novobiocin (47.0%) on round plates, and fosfomycin (36.5%) and chloramphenicol (84.0%) on square plates. With Enterobacteriaceae, 100% concordance was recorded for ampicillin, gentamicin and ciprofloxacin on round agar plates, and for gentamicin, cefoxitin and nalidixic acid on square plates. The poorest results were recorded for nalidixic acid (32.5%) and piperacillin (82.5%) on round plates, and for nitrofurantoin (72.5%) and amoxycillin (82.5%) on square plates. It was concluded that the OSIRIS system was a rapid and reliable system for measuring disk susceptibility test results on round and square agar plates.

  5. Polarization characterization of PZT disks and of embedded PZT plates by thermal wave methods

    SciTech Connect

    Eydam, Agnes Suchaneck, Gunnar Gerlach, Gerald; Esslinger, Sophia; Schönecker, Andreas; Neumeister, Peter

    2014-11-05

    In this work, the thermal wave method was applied to characterize PZT disks and embedded PZT plates with regard to the polarization magnitude and spatial homogeneity. The samples were exposed to periodic heating by means of a laser beam and the pyroelectric response was determined. Thermal relaxation times (single time constants or distributions of time constants) describe the heat losses of the PZT samples to the environment. The resulting pyroelectric current spectrum was fitted to the superposition of thermal relaxation processes. The pyroelectric coefficient gives insight in the polarization distribution. For PZT disks, the polarization distribution in the surface region showed a characteristic decrease towards the electrodes.

  6. Numerical Manifold Method for the Forced Vibration of Thin Plates during Bending

    PubMed Central

    Jun, Ding; Song, Chen; Wei-Bin, Wen; Shao-Ming, Luo; Xia, Huang

    2014-01-01

    A novel numerical manifold method was derived from the cubic B-spline basis function. The new interpolation function is characterized by high-order coordination at the boundary of a manifold element. The linear elastic-dynamic equation used to solve the bending vibration of thin plates was derived according to the principle of minimum instantaneous potential energy. The method for the initialization of the dynamic equation and its solution process were provided. Moreover, the analysis showed that the calculated stiffness matrix exhibited favorable performance. Numerical results showed that the generalized degrees of freedom were significantly fewer and that the calculation accuracy was higher for the manifold method than for the conventional finite element method. PMID:24883403

  7. Standard operating procedure to prepare agar phantoms

    NASA Astrophysics Data System (ADS)

    Souza, R. M.; Santos, T. Q.; Oliveira, D. P.; Souza, R. M.; Alvarenga, A. V.; Costa-Felix, R. P. B.

    2016-07-01

    Agar phantoms are widely used as soft tissue mimics and some preparation techniques are described in the literature. There are also standards that describe the recipe of a soft tissue mimicking material (TMM). However some details of manufacture process are not clearly defined. The standardization of the phantom's preparation can produce a metrological impact on the results of the acoustic properties measured. In this direction, this paper presents a standard operating procedure (SOP) to prepare the agar TMM described on the IEC 60601-237.

  8. An Inexpensive and Rapid Method for Preparing Thin-Layer Chromatography Plates for Use in the Classroom

    ERIC Educational Resources Information Center

    Sparrow, Susan; Rumsby, M. G.

    1976-01-01

    Describes a method in which glass plates are coated with adsorbent, using a technique which is cheap, rapid, and reliable; avoids the need for expensive, commercially-available thin layer chromatography equipment. (MLH)

  9. Silver-halide sensitized gelatin (SHSG) processing method for pulse holograms recorded on VRP plates

    NASA Astrophysics Data System (ADS)

    Evstigneeva, Maria K.; Drozdova, Olga V.; Mikhailov, Viktor N.

    2002-06-01

    One of the most important area of holograph applications is display holography. In case of pulse recording the requirement for vibration stability is easier than compared to CW exposure. At the same time it is widely known that the behavior of sliver-halide holographic materials strongly depends on the exposure duration. In particular the exposure sensitivity drastically decreases under nanosecond pulse duration. One of the effective ways of the diffraction efficiency improvement is SHSG processing method. This processing scheme is based on high modulation of refractive index due to microvoids appearance inside emulsion layer. It should be mentioned that the SHSG method was used earlier only in the cases when the holograms were recorded by use of CW lasers. This work is devoted to the investigation of SHSG method for pulse hologram recording on VRP plates. We used a pulsed YLF:Nd laser with pulse duration of 25 nanoseconds and wavelength of 527 nm. Both transmission and reflection holograms were recorded. The different kinds of bleaching as well as developing solutions were investigated. Our final processing scheme includes the following stages: 1) development in non-tanning solution, 2) rehalogenating bleach, 3) intermediate alcohol drying, 4) uniform second exposure, 5) second development in diluted developer, 6) reverse bleaching, 7) fixing and 8) gradient drying in isopropyl alcohol. Diffraction efficiency of transmission holograms was of about 60 percent and reflection mirror holograms was of about 45 percent. Thus we have demonstrated the SHSG processing scheme for producing effective holograms on VRP plates under pulse exposure.

  10. Method of producing exfoliated graphite composite compositions for fuel cell flow field plates

    DOEpatents

    Zhamu, Aruna; Shi, Jinjun; Guo, Jiusheng; Jang, Bor Z

    2014-04-08

    A method of producing an electrically conductive composite composition, which is particularly useful for fuel cell bipolar plate applications. The method comprises: (a) providing a supply of expandable graphite powder; (b) providing a supply of a non-expandable powder component comprising a binder or matrix material; (c) blending the expandable graphite with the non-expandable powder component to form a powder mixture wherein the non-expandable powder component is in the amount of between 3% and 60% by weight based on the total weight of the powder mixture; (d) exposing the powder mixture to a temperature sufficient for exfoliating the expandable graphite to obtain a compressible mixture comprising expanded graphite worms and the non-expandable component; (e) compressing the compressible mixture at a pressure within the range of from about 5 psi to about 50,000 psi in predetermined directions into predetermined forms of cohered graphite composite compact; and (f) treating the so-formed cohered graphite composite to activate the binder or matrix material thereby promoting adhesion within the compact to produce the desired composite composition. Preferably, the non-expandable powder component further comprises an isotropy-promoting agent such as non-expandable graphite particles. Further preferably, step (e) comprises compressing the mixture in at least two directions. The method leads to composite plates with exceptionally high thickness-direction electrical conductivity.

  11. [Laboratory-based evaluation of a selective X-SA agar medium supplemented with chromogenic substrate for Staphylococcus aureus].

    PubMed

    Nakasone, Isamu; Yamane, Nobuhisa

    2005-01-01

    The newly developed culture medium, X-SA agar medium (Nissui Pharmaceuticals Co., Ltd., Tokyo) selective for Staphylococcus aureus was evaluated for its ability to detect clinical isolates of S. aureus. Besides S. aureus, X-SA agar media allowed the growth of coagulase-negative staphylococci, Bacillus cereus and some isolates of corynebacteria. However, those species were easily distinguishable from the blue and convex colonies of S. aureus. When compared to the traditional egg yolk mannitol salt agar, selectivity for the species other than S. aureus was more specific, and growth support for S. aureus was more comparable to sheep blood agar. Also, when various phenotypic variants of S. aureus were inoculated, visible colonies of mucoid colony variants and attenuated growth variants on Mueller-Hinton agar appeared on X-SA agar plates after 24 hour-incubation, but it required 48 hour-incubation for small colony variants. The fully automated microbiology system, RAISUS (Nissui Pharmaceuticals Co., Ltd.) gave comparable species-identification and antimicrobial susceptibility test results when cell suspension directly prepared from X-SA agar media was tested. However, species-identification for phenotypic variants of S. aureus was more complicated for RAISUS testing and detection of coagulase. With these results, it could be concluded that the X-SA agar medium supplemented with chromogenic substrate is superior to the traditional selective media for the detection of S. aureus, and is widely applicable for clinical microbiology as well as food microbiology.

  12. Determination of plate waste in primary school lunches by weighing and visual estimation methods: a validation study.

    PubMed

    Liz Martins, Margarida; Cunha, Luís M; Rodrigues, Sara S P; Rocha, Ada

    2014-08-01

    The aim of this study was to validate the visual estimation method for aggregated plate waste of main dish at Portuguese primary school canteens. For this purpose plate waste at school lunch was measured for 505 individual servings, using weighing individual servings and plate waste and visual estimation method by a 6-point scale, as developed by Comstock et al. (1981). A high variability of initial serving weights was found with serving sizes ranging from 88.9 to 283.3g and with a coefficient of variation ranging from 5.5% to 24.7%. Mean plate waste was 27.5% according to the weighing method. There was a significant bias in the conversion of the visual waste estimations to actual waste, being overestimated by an average of 8.0 g (ranging from -12.9 g to 41.4 g). According to Bland and Altman plot, the mean difference between methods was of 8.0 g and the amplitude interval was 102.6g. The study showed that the visual estimation method is not as accurate as the weighing method in assessing nonselective aggregated plate waste at primary school canteens. Our findings are thus very important on considering plate waste assessment, since the wide variation on initial servings introduces a relevant bias when considering standard portions or a random sample of initial servings. Although, greater convenience, time-saving and the possibility to monitor plate waste of large groups, make the visual estimation method an important method to assess plate waste at school canteens, these results highlighted the need of portions standardization and control of initial servings to allow for its use. PMID:24841068

  13. Vectorization and parallelization of the finite strip method for dynamic Mindlin plate problems

    NASA Technical Reports Server (NTRS)

    Chen, Hsin-Chu; He, Ai-Fang

    1993-01-01

    The finite strip method is a semi-analytical finite element process which allows for a discrete analysis of certain types of physical problems by discretizing the domain of the problem into finite strips. This method decomposes a single large problem into m smaller independent subproblems when m harmonic functions are employed, thus yielding natural parallelism at a very high level. In this paper we address vectorization and parallelization strategies for the dynamic analysis of simply-supported Mindlin plate bending problems and show how to prevent potential conflicts in memory access during the assemblage process. The vector and parallel implementations of this method and the performance results of a test problem under scalar, vector, and vector-concurrent execution modes on the Alliant FX/80 are also presented.

  14. Use of agar agar stabilized milled zero-valent iron particles for in situ groundwater remediation

    NASA Astrophysics Data System (ADS)

    Schmid, Doris; Velimirović, Milica; Wagner, Stephan; Micić Batka, Vesna; von der Kammer, Frank; Hofmann, Thilo

    2015-04-01

    A major obstacle for use of nanoscale zero-valent iron (nZVI) particles as a nontoxic material for effective in situ degradation of chlorinated aliphatic hydrocarbons (CAHs) is the high production cost. For that reason, submicro-scale milled zero-valent iron particles were recently developed (milled ZVI, UVR-FIA, Germany) by grinding macroscopic raw materials of elementary iron as a cheaper alternative to products produced by solid-state reduction. However, milled ZVI particles tend to aggregate and due to the rather large particle size (d50= 11.9 µm) also rapidly sediment. To prevent aggregation and consequently sedimentation of milled ZVI particles and therefore improve the mobility after in situ application, the use of a stabilizer is considered in literature as a most promising option. In this study, milled ZVI particles (1 g L-1 of particle concentration) were stabilized by environmentally friendly polymer agar agar (>0.5 g L-1), which had a positive impact on the milled ZVI stability. Sedimentation rate was significantly decreased by increasing the suspension viscosity. Column transport experiments were performed for bare and agar agar stabilized milled ZVI particles in commercially available fine grained quartz sand (DORSILIT® Nr.8, Gebrüder Dorfner GmbH Co, Germany) and different porous media collected from brownfields. The experiments were carried out under field relevant injection conditions of 100 m d-1. The maximal travel distance (LT) of less than 10 cm was determined for non-stabilized suspension in fine grained quartz sand, while agar agar (1 g L-1) stabilized milled ZVI suspension revealed LT of 12 m. Similar results were observed for porous media from brownfields showing that mobility of agar agar stabilized particle suspensions was significantly improved compared to bare particles. Based on the mobility data, agar agar stabilized milled zero-valent iron particles could be used for in situ application. Finally, lab-scale batch degradation

  15. Comparison of dosimetry gels prepared by agar and bovine gelatine

    NASA Astrophysics Data System (ADS)

    Sağsöz, M. E.; Korkut, Ö.; Alemdar, N.; Aktaş, S.; Çalı, E. B.; Kantarcı, M.

    2016-04-01

    Gel dosimeters are unique materials capable of showing three dimensional (3D) dose distributions of therapeutic or diagnostic exposures. Fricke gel dosimeters can be considered as chemical dosimeters that rely on a radiation-induced chemical reaction. Dose distribution of Fricke solutions containing Fe+2 ions determines the transformation of acidic, oxygen saturated Fe+2 ions to Fe+3 ions by the ionizing radiation in aqueous solutions. In this study we produced two different types of gel dosimeters using agar and bovine gelatin with similar fabrication methods. We compared the magnetic resonance (MR) T1 imaging responses of these two gel dosimeters to acquire a dose dependency of MR intensities. In conclusion agar gel dosimeters found to be produced easily and more consistent.

  16. Luminescent DNA- and agar-based membranes.

    PubMed

    Leones, R; Fernandes, M; Ferreira, R A S; Cesarino, I; Lima, J F; Carlos, L D; Bermudez, V de Zea; Magon, C J; Donoso, J P; Silva, M M; Pawlicka, A

    2014-09-01

    Luminescent materials containing europium ions are investigated for different optical applications. They can be obtained using bio-macromolecules, which are promising alternatives to synthetic polymers based on the decreasing oil resources. This paper describes studies of the DNA- and Agar-europium triflate luminescent membranes and its potential technological applications are expanded to electroluminescent devices. Polarized optical microscopy demonstrated that the samples are birefringent with submicrometer anisotropy. The X-ray diffraction analysis revealed predominantly amorphous nature of the samples and the atomic force microscopy images showed a roughness of the membranes of 409.0 and 136.1 nm for the samples of DNA10Eu and Agar1.11Eu, respectively. The electron paramagnetic resonance spectra of the DNA(n)Eu membranes with the principal lines at g ≈ 2.0 and g ≈ 4.8 confirmed uniform distribution of rare earth ions in a disordered matrix. Moreover, these strong and narrow resonance lines for the samples of DNA(n)Eu when compared to the Agar(n)Eu suggested a presence of paramagnetic radicals arising from the DNA matrix. The emission spectra suggested that the Eu3+ ions occupy a single local environment in both matrices and the excitation spectra monitored around the Eu emission lines pointed out that the Eu3+ ions in the Agar host were mainly excited via the broad band component rather than by direct intra-4f(6) excitation, whereas the opposite case occurred for the DNA-based sample.

  17. Evaluation of cephamycins as supplements to selective agar for detecting Campylobacter spp. in chicken carcass rinses.

    PubMed

    Chon, Jung-Whan; Kim, Young-Ji; Kim, Hong-Seok; Kim, Dong-Hyeon; Kim, Hyunsook; Song, Kwang-Young; Sung, Kidon; Seo, Kun-Ho

    2016-04-16

    Although cefoperazone is the most commonly used antibiotic in Campylobacter-selective media, the distribution of cefoperazone-resistant bacteria such as extended-spectrum beta-lactamase (ESBL)-producing Escherichia coli is increasing. Here we evaluated the potential of cephamycins for use as supplements to improve modified charcoal-cefoperazone-deoxycholate agar (mCCDA) by replacing cefoperazone with the same concentrations (32 mg/L) of cefotetan (modified charcoal-cefotetan-deoxycholate agar, mCCtDA) and cefoxitin (modified charcoal-cefoxitin-deoxycholate agar, mCCxDA). In chicken carcass rinse samples, the number of mCCDA plates detecting for Campylobacter (18/70, 26%) was significantly lower than that of mCCtDA (42/70, 60%) or mCCxDA plates (40/70, 57%). The number of mCCDA plates (70/70, 100%) that were contaminated with non-Campylobacter species was significantly higher than that of mCCtDA (20/70, 29%) or mCCxDA plates (21/70, 30%). The most common competing species identified using mCCDA was ESBL-producing E. coli, while Pseudomonas species frequently appeared on mCCtDA and mCCxDA.

  18. Rapid Direct Testing of Susceptibility of Mycobacterium tuberculosis to Isoniazid and Rifampin on Nutrient and Blood Agar in Resource-Starved Settings

    PubMed Central

    Ikram, Aamer; Coban, Ahmet Yilmaz; Martin, Anandi

    2012-01-01

    In this study, we evaluated the performance of blood agar (by macroscopic growth) and nutrient agar (by a microcolony detection method) for drug susceptibility testing of Mycobacterium tuberculosis against rifampin (RIF) and isoniazid (INH), using 67 smear-positive sputum specimens. The direct proportion method on Lowenstein-Jensen (LJ) medium was used as the “gold standard.” Compared with LJ medium, results for both media were in 100% agreement for RIF, while for INH the agreement levels for blood agar and nutrient agar were 98% and 95%, respectively. Within 2 weeks, 100% of specimens yielded results on blood agar, while 96.8% of specimens yielded results on nutrient agar. Our study showed that blood agar and nutrient agar can be used as alternative media for direct susceptibility testing of RIF and INH, especially in resource-poor settings. PMID:22357498

  19. Rapid direct testing of susceptibility of Mycobacterium tuberculosis to isoniazid and rifampin on nutrient and blood agar in resource-starved settings.

    PubMed

    Satti, Luqman; Ikram, Aamer; Coban, Ahmet Yilmaz; Martin, Anandi

    2012-05-01

    In this study, we evaluated the performance of blood agar (by macroscopic growth) and nutrient agar (by a microcolony detection method) for drug susceptibility testing of Mycobacterium tuberculosis against rifampin (RIF) and isoniazid (INH), using 67 smear-positive sputum specimens. The direct proportion method on Lowenstein-Jensen (LJ) medium was used as the "gold standard." Compared with LJ medium, results for both media were in 100% agreement for RIF, while for INH the agreement levels for blood agar and nutrient agar were 98% and 95%, respectively. Within 2 weeks, 100% of specimens yielded results on blood agar, while 96.8% of specimens yielded results on nutrient agar. Our study showed that blood agar and nutrient agar can be used as alternative media for direct susceptibility testing of RIF and INH, especially in resource-poor settings.

  20. A novel diagnosis method for a Hall plates-based rotary encoder with a magnetic concentrator.

    PubMed

    Meng, Bumin; Wang, Yaonan; Sun, Wei; Yuan, Xiaofang

    2014-01-01

    In the last few years, rotary encoders based on two-dimensional complementary metal oxide semiconductors (CMOS) Hall plates with a magnetic concentrator have been developed to measure contactless absolute angle. There are various error factors influencing the measuring accuracy, which are difficult to locate after the assembly of encoder. In this paper, a model-based rapid diagnosis method is presented. Based on an analysis of the error mechanism, an error model is built to compare minimum residual angle error and to quantify the error factors. Additionally, a modified particle swarm optimization (PSO) algorithm is used to reduce the calculated amount. The simulation and experimental results show that this diagnosis method is feasible to quantify the causes of the error and to reduce iteration significantly. PMID:25090417

  1. Minimum stiffness location of point support for control of fundamental natural frequency of rectangular plate by Rayleigh-Ritz method

    NASA Astrophysics Data System (ADS)

    Wang, D.; Yang, Z. C.; Yu, Z. G.

    2010-07-01

    The Rayleigh-Ritz method is employed to determine the minimum stiffness location of the elastic point support for raising the fundamental natural frequency of a rectangular plate to the second frequency of the unsupported plate, which usually is the upper limit of the first frequency for a single support. Based on the optimal design of the support position, the minimum stiffness can be obtained numerically by solving a characteristic eigenvalue sub-problem. In the Rayleigh-Ritz procedure the boundary characteristic orthogonal polynomials are used for the admissible functions. Several typical examples of plate structures with the additional point supports are analyzed in detail, and the results prove that the proposed method is very effective in the solution to the optimal design of the supports. It will be shown that elastic supports can be designed like rigid ones for the purpose of increasing the fundamental natural frequency of a rectangular plate.

  2. Petrifilm rapid S. aureus Count Plate method for rapid enumeration of Staphylococcus aureus in selected foods: collaborative study.

    PubMed

    Silbernagel, K M; Lindberg, K G

    2001-01-01

    A rehydratable dry-film plating method for Staphylococcus aureus in foods, the 3M Petrifilm Rapid S. aureus Count Plate method, was compared with AOAC Official Method 975.55 (Staphylococcus aureus in Foods). Nine foods-instant nonfat dried milk, dry seasoned vegetable coating, frozen hash browns, frozen cooked chicken patty, frozen ground raw pork, shredded cheddar cheese, fresh green beans, pasta filled with beef and cheese, and egg custard-were analyzed for S. aureus by 13 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample and 3 levels of inoculated test sample, each in duplicate. The mean log counts for the methods were comparable for pasta filled with beef and cheese; frozen hash browns; cooked chicken patty; egg custard; frozen ground raw pork; and instant nonfat dried milk. The repeatability and reproducibility variances of the Petrifilm Rapid S. aureus Count Plate method were similar to those of the standard method.

  3. A negative-norm least squares method for Reissner-Mindlin plates

    NASA Astrophysics Data System (ADS)

    Bramble, J. H.; Sun, T.

    1998-07-01

    In this paper a least squares method, using the minus one norm developed by Bramble, Lazarov, and Pasciak, is introduced to approximate the solution of the Reissner-Mindlin plate problem with small parameter t, the thickness of the plate. The reformulation of Brezzi and Fortin is employed to prevent locking. Taking advantage of the least squares approach, we use only continuous finite elements for all the unknowns. In particular, we may use continuous linear finite elements. The difficulty of satisfying the inf-sup condition is overcome by the introduction of a stabilization term into the least squares bilinear form, which is very cheap computationally. It is proved that the error of the discrete solution is optimal with respect to regularity and uniform with respect to the parameter t. Apart from the simplicity of the elements, the stability theorem gives a natural block diagonal preconditioner of the resulting least squares system. For each diagonal block, one only needs a preconditioner for a second order elliptic problem.

  4. Comparison of Primary Models to Predict Microbial Growth by the Plate Count and Absorbance Methods.

    PubMed

    Pla, María-Leonor; Oltra, Sandra; Esteban, María-Dolores; Andreu, Santiago; Palop, Alfredo

    2015-01-01

    The selection of a primary model to describe microbial growth in predictive food microbiology often appears to be subjective. The objective of this research was to check the performance of different mathematical models in predicting growth parameters, both by absorbance and plate count methods. For this purpose, growth curves of three different microorganisms (Bacillus cereus, Listeria monocytogenes, and Escherichia coli) grown under the same conditions, but with different initial concentrations each, were analysed. When measuring the microbial growth of each microorganism by optical density, almost all models provided quite high goodness of fit (r(2) > 0.93) for all growth curves. The growth rate remained approximately constant for all growth curves of each microorganism, when considering one growth model, but differences were found among models. Three-phase linear model provided the lowest variation for growth rate values for all three microorganisms. Baranyi model gave a variation marginally higher, despite a much better overall fitting. When measuring the microbial growth by plate count, similar results were obtained. These results provide insight into predictive microbiology and will help food microbiologists and researchers to choose the proper primary growth predictive model. PMID:26539483

  5. Comparison of Primary Models to Predict Microbial Growth by the Plate Count and Absorbance Methods

    PubMed Central

    Pla, María-Leonor; Oltra, Sandra; Esteban, María-Dolores; Andreu, Santiago; Palop, Alfredo

    2015-01-01

    The selection of a primary model to describe microbial growth in predictive food microbiology often appears to be subjective. The objective of this research was to check the performance of different mathematical models in predicting growth parameters, both by absorbance and plate count methods. For this purpose, growth curves of three different microorganisms (Bacillus cereus, Listeria monocytogenes, and Escherichia coli) grown under the same conditions, but with different initial concentrations each, were analysed. When measuring the microbial growth of each microorganism by optical density, almost all models provided quite high goodness of fit (r2 > 0.93) for all growth curves. The growth rate remained approximately constant for all growth curves of each microorganism, when considering one growth model, but differences were found among models. Three-phase linear model provided the lowest variation for growth rate values for all three microorganisms. Baranyi model gave a variation marginally higher, despite a much better overall fitting. When measuring the microbial growth by plate count, similar results were obtained. These results provide insight into predictive microbiology and will help food microbiologists and researchers to choose the proper primary growth predictive model. PMID:26539483

  6. Comparison of Primary Models to Predict Microbial Growth by the Plate Count and Absorbance Methods.

    PubMed

    Pla, María-Leonor; Oltra, Sandra; Esteban, María-Dolores; Andreu, Santiago; Palop, Alfredo

    2015-01-01

    The selection of a primary model to describe microbial growth in predictive food microbiology often appears to be subjective. The objective of this research was to check the performance of different mathematical models in predicting growth parameters, both by absorbance and plate count methods. For this purpose, growth curves of three different microorganisms (Bacillus cereus, Listeria monocytogenes, and Escherichia coli) grown under the same conditions, but with different initial concentrations each, were analysed. When measuring the microbial growth of each microorganism by optical density, almost all models provided quite high goodness of fit (r(2) > 0.93) for all growth curves. The growth rate remained approximately constant for all growth curves of each microorganism, when considering one growth model, but differences were found among models. Three-phase linear model provided the lowest variation for growth rate values for all three microorganisms. Baranyi model gave a variation marginally higher, despite a much better overall fitting. When measuring the microbial growth by plate count, similar results were obtained. These results provide insight into predictive microbiology and will help food microbiologists and researchers to choose the proper primary growth predictive model.

  7. Extraction of gadolinium from high flux isotope reactor control plates. [Alternative method

    SciTech Connect

    Kohring, M.W.

    1987-04-01

    Gadolinium-153 is an important radioisotope used in the diagnosis of various bone disorders. Recent medical and technical developments in the detection and cure of osteoporosis, a bone disease affecting an estimated 50 million people, have greatly increased the demand for this isotope. The Oak Ridge National Laboratory (ORNL) has produced /sup 153/Gd since 1980 primarily through the irradiation of a natural europium-oxide powder followed by the chemical separation of the gadolinium fraction from the europium material. Due to the higher demand for /sup 153/Gd, an alternative production method to supplement this process has been investigated. This process involves the extraction of gadolinium from the europium-bearing region of highly radioactive, spent control plates used at the High Flux Isotope Reactor (HFIR) with a subsequent re-irradiation of the extracted material for the production of the /sup 153/Gd. Based on the results of experimental and calculational analyses, up to 25 grams of valuable gadolinium (greater than or equal to60% enriched in /sup 152/Gd) resides in the europium-bearing region of the HFIR control components of which 70% is recoverable. At a specific activity yield of 40 curies of /sup 153/Gd for each gram of gadolinium re-irradiated, 700 one-curie sources can be produced from each control plate assayed.

  8. Management of infectious fractures with "Non-Contact Plate" (NCP) method.

    PubMed

    Alemdar, Celil; Azboy, Ibrahim; Atiç, Ramazan; Özkul, Emin; Gem, Mehmet; Kapukaya, Ahmet

    2015-09-01

    The aim of this study was to evaluate the outcomes of internal fixation with Non-Contact Plating (NCP) after deep infection caused by previous surgeries of the tibia or femur fractures. The study included 15 patients (4 female and 11 male). The mean age patients was 36.6 years (range, 21-64 years). There were 6 femur and 9 tibia fractures. The mean follow-up period was 25.7 months (range, 15-45 months). The study comprised 11 open and 4 closed fractures. External fixator was used in 3, plate in 4, and intramedullary nail in 8 patients for index surgery. Deep infection was diagnosed via clinical findings, laboratory parameters, and microbiological evaulation. Deep infection was diagnosed within a mean period of 5.5 weeks (range, 2-10 weeks). The infecting organism was methicillin-resistant staphylococcus aureus (MRSA) in 5, methicillin-sensitive staphylococcus aureus (MSSA) in 6, pseudomonas auroginosa in 2, and enterobacteriacea in 2 patients. Union achieved in all patients. Mean time to union was 17 (range, 11-38) weeks. Delayed union was observed in 3 patients who required additional surgeries. Of these one patient developed osteomyelitis. The NCP is an effective alternative method in the treatment of deep infection encountered after internal or external fixation for the tibia, or femur fractures.

  9. Management of infectious fractures with "Non-Contact Plate" (NCP) method.

    PubMed

    Alemdar, Celil; Azboy, Ibrahim; Atiç, Ramazan; Özkul, Emin; Gem, Mehmet; Kapukaya, Ahmet

    2015-09-01

    The aim of this study was to evaluate the outcomes of internal fixation with Non-Contact Plating (NCP) after deep infection caused by previous surgeries of the tibia or femur fractures. The study included 15 patients (4 female and 11 male). The mean age patients was 36.6 years (range, 21-64 years). There were 6 femur and 9 tibia fractures. The mean follow-up period was 25.7 months (range, 15-45 months). The study comprised 11 open and 4 closed fractures. External fixator was used in 3, plate in 4, and intramedullary nail in 8 patients for index surgery. Deep infection was diagnosed via clinical findings, laboratory parameters, and microbiological evaulation. Deep infection was diagnosed within a mean period of 5.5 weeks (range, 2-10 weeks). The infecting organism was methicillin-resistant staphylococcus aureus (MRSA) in 5, methicillin-sensitive staphylococcus aureus (MSSA) in 6, pseudomonas auroginosa in 2, and enterobacteriacea in 2 patients. Union achieved in all patients. Mean time to union was 17 (range, 11-38) weeks. Delayed union was observed in 3 patients who required additional surgeries. Of these one patient developed osteomyelitis. The NCP is an effective alternative method in the treatment of deep infection encountered after internal or external fixation for the tibia, or femur fractures. PMID:26435249

  10. Methods and formulas for calculating the strength of plate and shell constructions as used in airplane design

    NASA Technical Reports Server (NTRS)

    Heck, O S; Ebner, H

    1936-01-01

    This report is a compilation of previously published articles on formulas and methods of calculation for the determination of the strength and stability of plate and shell construction as employed in airplane design. In particular, it treats the problem of isotropic, orthotopic, and stiffened rectangular plates, thin curved panels, and circular cylinders under various loading conditions. The purpose of appending the pertinent literature references following the subjects discussed was to facilitate a comprehensive study of the treated problems.

  11. Modeling of the Bacillus subtilis Bacterial Biofilm Growing on an Agar Substrate

    PubMed Central

    Wang, Xiaoling; Wang, Guoqing; Hao, Mudong

    2015-01-01

    Bacterial biofilms are organized communities composed of millions of microorganisms that accumulate on almost any kinds of surfaces. In this paper, a biofilm growth model on an agar substrate is developed based on mass conservation principles, Fick's first law, and Monod's kinetic reaction, by considering nutrient diffusion between biofilm and agar substrate. Our results show biofilm growth evolution characteristics such as biofilm thickness, active biomass, and nutrient concentration in the agar substrate. We quantitatively obtain biofilm growth dependence on different parameters. We provide an alternative mathematical method to describe other kinds of biofilm growth such as multiple bacterial species biofilm and also biofilm growth on various complex substrates. PMID:26355542

  12. Modeling of the Bacillus subtilis Bacterial Biofilm Growing on an Agar Substrate.

    PubMed

    Wang, Xiaoling; Wang, Guoqing; Hao, Mudong

    2015-01-01

    Bacterial biofilms are organized communities composed of millions of microorganisms that accumulate on almost any kinds of surfaces. In this paper, a biofilm growth model on an agar substrate is developed based on mass conservation principles, Fick's first law, and Monod's kinetic reaction, by considering nutrient diffusion between biofilm and agar substrate. Our results show biofilm growth evolution characteristics such as biofilm thickness, active biomass, and nutrient concentration in the agar substrate. We quantitatively obtain biofilm growth dependence on different parameters. We provide an alternative mathematical method to describe other kinds of biofilm growth such as multiple bacterial species biofilm and also biofilm growth on various complex substrates.

  13. Cell aggregation on agar as an indicator for cell-matrix adhesion: effects of opioids.

    PubMed

    Debruyne, Delphine; Mareel, Marc; Vanhoecke, Barbara; Bracke, Marc

    2009-09-01

    The slow aggregation assay is generally used to study the functionality of cell-cell adhesion complexes. Single cells are seeded on a semisolid agar substrate in a 96-well plate and the cells spontaneously aggregate. We used HEK FLAG-MOP cells that stably overexpress the mu opioid receptor and the mu-opioid-receptor-selective agonists DAMGO and morphine to study whether other factors than functionality of cell-cell adhesions complexes can contribute to changes in the pattern of slow aggregation on agar. HEK FLAG-MOP cells formed small compact aggregates. In the presence of DAMGO and morphine, larger and fewer aggregates were formed in comparison to the vehicle control. These aggregates were localized in the center of the agar surface, whereas in the vehicle control they were dispersed over the substrate. However, in suspension culture on a Gyrotory shaker, no stimulation of aggregation was observed by DAMGO and morphine, showing that opioids do not affect affinity. A dissociation experiment revealed that HEK FLAG-MOP aggregates formed in the absence or presence of opioids are resistant to de-adhesion. We demonstrated that the larger aggregates are neither the result of cell growth stimulation by DAMGO and morphine. Since manipulations of the substrate such as increasing the agar concentration or mixing agar with agarose induced the same changes in the pattern of slow aggregation as treatment with opioids, we suggest that cell-substrate adhesion may be involved in opioid-stimulated aggregation.

  14. Population cell differentiation of Serratia marcescens on agar surface and in broth culture.

    PubMed

    Lai, H C; Lai, M J; Lin-Chao, S; Lu, K T; Ho, S W

    1997-11-01

    The bacterium Serratia marcescens shows population surface migration (swarming) phenomenum on an LB swarming plate, and differentiated cells can be observed at the swarming front. How the cell population differentiates during swarming on the agar surface is not known, neither is it clear whether cells with differentiated characteristics can be observed in broth culture. To monitor the population cell differentiation in a highly sensitive way without cell destruction, experiments were designed using bacterial luciferase genes luxAB as the reporter genes to allow direct monitoring of the differentiating cells through bioluminescence. An isogenic S. marcescens strain was constructed with luxAB under the control of the promoter of flagellin gene hag (phag::luxAB). Patterns of cell differentiation were monitored either by direct X-ray film exposure and/or by Autolumat luminometer detection. Results show that population cell differentiation on the agar surface occurs first in a temporal and then spatial way during colonial growth. It was also found that cells harvested from both the spreading agar plate and broth culture showed differentiation patterns similar to those from swarming cells, suggesting that the agar surface culture may not be essential for the formation of differentiated cells.

  15. Coupling equivalent plate and finite element formulations in multiple-method structural analyses

    NASA Technical Reports Server (NTRS)

    Giles, Gary L.; Norwood, Keith

    1994-01-01

    A coupled multiple-method analysis procedure for use late in conceptual design or early in preliminary design of aircraft structures is described. Using this method, aircraft wing structures are represented with equivalent plate models, and structural details such as engine/pylon structure, landing gear, or a 'stick' model of a fuselage are represented with beam finite element models. These two analysis methods are implemented in an integrated multiple-method formulation that involves the assembly and solution of a combined set of linear equations. The corresponding solution vector contains coefficients of the polynomials that describe the deflection of the wing and also the components of translations and rotations at the joints of the beam members. Two alternative approaches for coupling the methods are investigated; one using transition finite elements and the other using Lagrange multipliers. The coupled formulation is applied to the static analysis and vibration analysis of a conceptual design model of a fighter aircraft. The results from the coupled method are compared with corresponding results from an analysis in which the entire model is composed of finite elements.

  16. An Empirical Method for Fast Prediction of Rarefied Flow Field around a Vertical Plate

    NASA Astrophysics Data System (ADS)

    He, Tao; Wang, Jiang-Feng

    2016-06-01

    Numerical study is conducted to investigate the effects of free-stream Knudsen (Kn) number on rarefied flow field around a vertical plate employing an unstructured DSMC method, and an empirical method for fast prediction of flow-field structure at different Kn numbers in a given inflow velocity is proposed. First, the flow at a velocity 7500m/s is simulated using a perfect-gas model with free-stream Kn changing from 0.035 to 13.36. The flow-field characteristics in these cases with varying Kn numbers are analyzed and a linear-expansion phenomenon as a function of the square of Kn is discovered. An empirical method is proposed for fast flow-field prediction at different Kn based on the least-square-fitting method. Further, the effects of chemical reactions on flow field are investigated to verify the applicability of the empirical method in the real gas conditions. Three of the cases in perfect-gas flow are simulated again by introducing five-species air chemical module. The flow properties with and without chemical reactions are compared. In the end, the variation of chemical-reaction flow field as a function of Kn is analyzed and it is shown that the empirical method are also suitable when considering chemical reactions.

  17. Blood agar validation for susceptibility testing of isoniazid, rifampicin, ethambutol, and streptomycin to Mycobacterium tuberculosis isolates.

    PubMed

    Coban, Ahmet Yilmaz

    2013-01-01

    In recent studies, it was shown that blood agar can be used at least as effectively as Löwenstein-Jensen medium for growing Mycobacterium tuberculosis. It was also shown that susceptibility testing can be performed on blood agar. Additional validation of blood agar was performed on regional M. tuberculosis isolates from Turkey to determine critical concentrations of isoniazid (INH), rifampicin (RIF), ethambutol (ETM), and streptomycin (STR). In the current study, 40 M. tuberculosis clinical isolates were tested. H37Rv, which is susceptible to all antituberculosis agents, ATCC 35822 (INH-resistant), ATCC 35838 (RIF-resistant), ATCC 35837 (ETM-resistant), and ATCC 35820 (STR-resistant) quality control strains were used as control strains. Proportion method on 7H11 agar was considered as gold standard in the study. MIC values of the control strains and clinical isolates were detected on blood and 7H11 agar. Categorical agreements were 100% for each antibiotic, and essential agreements were 100%, 97.5%, 82.5%, and 95% for INH, RIF, ETM, and STR, respectively. According to the data, 0.2 µg/mL for INH, 1 µg/mL for RIF, 4 µg/mL for ETM, and 2 µg/mL for STR were appropriate breakpoint values for susceptibility testing on blood agar. Blood agar may be recommended for use in both developed and developing countries for the susceptibility testing of M. tuberculosis isolates to primary antituberculosis drugs.

  18. [A new method for evaluation of the antagonistic action of bacterial lactic acid (LAB) on selected pathogenic indicator bacteria].

    PubMed

    Strus, M

    1998-01-01

    A comparison was made of three methods: paper disc, double layer and a newly proposed agar slab techniques for testing antibacterial activity of Lactobacillus strains. Strains of indicator bacteria were selected from important pathogens of the human alimentary and genitourinary tract. The agar slab method, which is based on applying of slabs of MRS agar with overnight growth of the antagonistic bacteria to the surface of appropriate agar plates seeded with indicator bacteria, appeared to be the only method suitable for testing of aerobic and anaerobic fastidious bacteria. After testing of 27 Lactobacillus strains against 3 selected indicator bacteria: E. coli, Salmonella enteritidis and Staphylococcus aureus, calculating mean values and standard deviations for diameters of inhibitory zones and making variance analysis it was shown that in comparison to other methods the agar slab technique, although less sensitive than others, gave most consistent and reproducible results.

  19. Experimental comparison and validation of hot-ball method with guarded hot plate method on polyurethane foams

    NASA Astrophysics Data System (ADS)

    Hudec, Ján; Glorieux, Christ; Dieška, Peter; Kubičár, Ľudovít

    2016-07-01

    The Hot-ball method is an innovative transient method for measuring thermophysical properties. The principle is based on heating of a small ball, incorporated in measured medium, by constant heating power and simultaneous measuring of the ball's temperature response since the heating was initiated. The shape of the temperature response depends on thermophysical properties of the medium, where the sensor is placed. This method is patented by Institute of Physics, SAS, where the method and sensors based on this method are being developed. At the beginning of the development of sensors for this method we were oriented on monitoring applications, where relative precision is much more important than accuracy. Meanwhile, the quality of sensors was improved good enough to be used for a new application - absolute measuring of thermophysical parameters of low thermally conductive materials. This paper describes experimental verification and validation of measurement by hot-ball method. Thanks to cooperation with Laboratory of Soft Matter and Biophysics of Catholic University of Leuven in Belgium, established Guarded Hot Plate method was used as a reference. Details about measuring setups, description of the experiments and results of the comparison are presented.

  20. High accuracy position response calibration method for a micro-channel plate ion detector

    NASA Astrophysics Data System (ADS)

    Hong, R.; Leredde, A.; Bagdasarova, Y.; Fléchard, X.; García, A.; Müller, P.; Knecht, A.; Liénard, E.; Kossin, M.; Sternberg, M. G.; Swanson, H. E.; Zumwalt, D. W.

    2016-11-01

    We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an in situ calibration mask, an accuracy of 8 μm and a resolution of 85 μm (FWHM) have been achieved for MeV-scale α particles and ions with energies of ∼10 keV. At this level of accuracy, the difference between the MCP position responses to high-energy α particles and low-energy ions is significant. The improved performance of the MCP detector can find applications in many fields of AMO and nuclear physics. In our case, it helps reducing systematic uncertainties in a high-precision nuclear β-decay experiment.

  1. A study of turbulent flow between parallel plates by a statistical method

    NASA Technical Reports Server (NTRS)

    Srinivasan, R.; Giddens, D. P.; Bangert, L. H.; Wu, J. C.

    1976-01-01

    Turbulent Couette flow between parallel plates was studied from a statistical mechanics approach utilizing a model equation, similar to the Boltzmann equation of kinetic theory, which was proposed by Lundgren from the velocity distribution of fluid elements. Solutions to this equation are obtained numerically, employing the discrete ordinate method and finite differences. Two types of boundary conditions on the distribution function are considered, and the results of the calculations are compared to available experimental data. The research establishes that Lundgren's equation provides a very good description of turbulence for the flow situation considered and that it offers an analytical tool for further study of more complex turbulent flows. The present work also indicates that modelling of the boundary conditions is an area where further study is required.

  2. A New XRD Method to Quantify Plate and Lath Martensites of Hardened Medium-Carbon Steel

    NASA Astrophysics Data System (ADS)

    Luo, Quanshun

    2016-06-01

    This paper introduces a new technique to separately measure the volume fraction and tetragonal ratio of co-existing lath and plate martensites in ultrahigh strength steel, and to calculate their different carbon contents. First, the two martensites are assumed to have body-centered tetragonal lattice structures of different tetragonal ratios. X-ray diffraction is then applied to obtain the overlapping {200} diffraction peak, which is subsequently separated as four sub-peaks using a self-made multiple Gaussian peak-fitting method to allow the measurement of the individual lattice parameters c and a. Finally, a modified equation is applied to calculate the carbon contents from the obtained tetragonal ratios. The new technique is then applied to investigate the effect of subsequent tempering on the decarbonization of the as-quenched martensites.

  3. Piezoelectrically forced vibrations of electroded doubly rotated quartz plates by state space method

    NASA Technical Reports Server (NTRS)

    Chander, R.

    1990-01-01

    The purpose of this investigation is to develop an analytical method to study the vibration characteristics of piezoelectrically forced quartz plates. The procedure can be summarized as follows. The three dimensional governing equations of piezoelectricity, the constitutive equations and the strain-displacement relationships are used in deriving the final equations. For this purpose, a state vector consisting of stresses and displacements are chosen and the above equations are manipulated to obtain the projection of the derivative of the state vector with respect to the thickness coordinate on to the state vector itself. The solution to the state vector at any plane is then easily obtained in a closed form in terms of the state vector quantities at a reference plane. To simplify the analysis, simple thickness mode and plane strain approximations are used.

  4. Algorithm for detecting seam cracks in steel plates using a Gabor filter combination method.

    PubMed

    Choi, Doo-Chul; Jeon, Yong-Ju; Lee, Sang Jun; Yun, Jong Pil; Kim, Sang Woo

    2014-08-01

    Presently, product inspection based on vision systems is an important part of the steel-manufacturing industry. In this work, we focus on the detection of seam cracks in the edge region of steel plates. Seam cracks are generated in the vertical direction, and their width range is 0.2-0.6 mm. Moreover, the gray values of seam cracks are only 20-30 gray levels lower than those of the neighboring surface. Owing to these characteristics, we propose a new algorithm for detecting seam cracks using a Gabor filter combination method. To enhance the performance, we extracted features of seam cracks and employed a support vector machine classifier. The experimental results show that the proposed algorithm is suitable for detecting seam cracks.

  5. Single Transducer Ultrasonic Imaging Method that Eliminates the Effect of Plate Thickness Variation in the Image

    NASA Technical Reports Server (NTRS)

    Roth, Don J.

    1996-01-01

    This article describes a single transducer ultrasonic imaging method that eliminates the effect of plate thickness variation in the image. The method thus isolates ultrasonic variations due to material microstructure. The use of this method can result in significant cost savings because the ultrasonic image can be interpreted correctly without the need for machining to achieve precise thickness uniformity during nondestructive evaluations of material development. The method is based on measurement of ultrasonic velocity. Images obtained using the thickness-independent methodology are compared with conventional velocity and c-scan echo peak amplitude images for monolithic ceramic (silicon nitride), metal matrix composite and polymer matrix composite materials. It was found that the thickness-independent ultrasonic images reveal and quantify correctly areas of global microstructural (pore and fiber volume fraction) variation due to the elimination of thickness effects. The thickness-independent ultrasonic imaging method described in this article is currently being commercialized under a cooperative agreement between NASA Lewis Research Center and Sonix, Inc.

  6. A semi-analytical method to evaluate the dynamic response of functionally graded plates subjected to underwater shock

    NASA Astrophysics Data System (ADS)

    Liang, Xu; Wang, Zhenyu; Wang, Lizhong; Izzuddin, Bassam A.; Liu, Guohua

    2015-02-01

    Functionally graded (FG) plates are of current interest and are widely used in a variety of applications including deep sea exploration and naval/marine and coastal engineering, despite the fact that there has, to date, been little research undertaken on the subject. In order to remedy the situation, an analytical method to investigate the elastic dynamic responses of FG plates to underwater shock is proposed here, their material properties varying by the same exponential law along the thickness direction. Taylor's one dimensional fluid solid interaction (FSI) model is extended to fit a three dimensional model suitable for FG plates. The extended FSI model and Laplace transform are integrated into the state space method, with the transient solution in the time domain being obtained by using the numerical inversion of the Laplace transform. The solutions of the total forces acting throughout the front and back faces in the time domain are derived for the first time. The present method is validated by comparing it with the results of other methods and experiments found in the relevant literature. The influence of the boundary conditions at the backside of the plate and FG parameters on front and back side pressures, cavitations, displacements, stresses and total forces acting throughout the faces are then investigated, with the time progression of the cavitation areas of air-backed plates and water-backed plates being investigated in detail. The method proposed in this paper may prove useful for the future three-dimensional assessment of the response of FG structures when FSI effects are taken into consideration. It is hoped that the results will lead to a full understanding of the mechanism of the interaction between fluid and an FG plate, and that they can be used as benchmark solutions in further research.

  7. Variable-node plate and shell elements with assumed natural strain and smoothed integration methods for nonmatching meshes

    NASA Astrophysics Data System (ADS)

    Sohn, Dongwoo; Im, Seyoung

    2013-06-01

    In this paper, novel finite elements that include an arbitrary number of additional nodes on each edge of a quadrilateral element are proposed to achieve compatible connection of neighboring nonmatching meshes in plate and shell analyses. The elements, termed variable-node plate elements, are based on two-dimensional variable-node elements with point interpolation and on the Mindlin-Reissner plate theory. Subsequently the flat shell elements, termed variable-node shell elements, are formulated by further extending the plate elements. To eliminate a transverse shear locking phenomenon, the assumed natural strain method is used for plate and shell analyses. Since the variable-node plate and shell elements allow an arbitrary number of additional nodes and overcome locking problems, they make it possible to connect two nonmatching meshes and to provide accurate solutions in local mesh refinement. In addition, the curvature and strain smoothing methods through smoothed integration are adopted to improve the element performance. Several numerical examples are presented to demonstrate the effectiveness of the elements in terms of the accuracy and efficiency of the analyses.

  8. Luminescent DNA- and agar-based membranes.

    PubMed

    Leones, R; Fernandes, M; Ferreira, R A S; Cesarino, I; Lima, J F; Carlos, L D; Bermudez, V de Zea; Magon, C J; Donoso, J P; Silva, M M; Pawlicka, A

    2014-09-01

    Luminescent materials containing europium ions are investigated for different optical applications. They can be obtained using bio-macromolecules, which are promising alternatives to synthetic polymers based on the decreasing oil resources. This paper describes studies of the DNA- and Agar-europium triflate luminescent membranes and its potential technological applications are expanded to electroluminescent devices. Polarized optical microscopy demonstrated that the samples are birefringent with submicrometer anisotropy. The X-ray diffraction analysis revealed predominantly amorphous nature of the samples and the atomic force microscopy images showed a roughness of the membranes of 409.0 and 136.1 nm for the samples of DNA10Eu and Agar1.11Eu, respectively. The electron paramagnetic resonance spectra of the DNA(n)Eu membranes with the principal lines at g ≈ 2.0 and g ≈ 4.8 confirmed uniform distribution of rare earth ions in a disordered matrix. Moreover, these strong and narrow resonance lines for the samples of DNA(n)Eu when compared to the Agar(n)Eu suggested a presence of paramagnetic radicals arising from the DNA matrix. The emission spectra suggested that the Eu3+ ions occupy a single local environment in both matrices and the excitation spectra monitored around the Eu emission lines pointed out that the Eu3+ ions in the Agar host were mainly excited via the broad band component rather than by direct intra-4f(6) excitation, whereas the opposite case occurred for the DNA-based sample. PMID:25924317

  9. A simple and efficient method of analyzing mechanical behaviors of multi-layered orthotropic plates in rectangular shape

    NASA Astrophysics Data System (ADS)

    Chai Lee, Byung; Sok Kim, Eun

    1999-12-01

    We apply the Rayleigh-Ritz method to analyze multi-layered plates with residual stresses for membrane and bending deformation. The method is very simple, straightforward, and easily programmable, but it should be applied to structures only with simple shapes. We derive coupled variational equations using the principle of virtual displacement, and investigate what kind of basis functions are desirable for the analysis of rectangular plates with various boundary conditions. We demonstrate the effectiveness and usefulness of the present method through several examples. The analysis results obtained with the present method are in good agreement with those available in the literature. A multi-layered microelectromechanical plate example shows that the coupling effect between membrane and bending deformation should not be ignored and that residual stresses do significantly influence the stiffness of the structure.

  10. Comparison of a quantitative microtiter method, a quantitative automated method, and the plate-count method for determining microbial complement resistance.

    PubMed

    Lee, M D; Wooley, R E; Brown, J; Spears, K R; Nolan, L K; Shotts, E B

    1991-01-01

    A quantitative microtiter method for determining the degree of complement resistance or sensitivity of microorganisms is described. The microtiter method is compared with a quantitative automated system and the standard plate-count technique. Data were accumulated from 30 avian Escherichia coli isolates incubated at 35 C with either chicken plasma or heat-inactivated chicken plasma. Analysis of data generated by the automated system and plate-count techniques resulted in a classification of the microorganisms into three groups: those sensitive to the action of complement; those of intermediate sensitivity to the action of complement; and those resistant to the action of complement. Although the three methods studied did not agree absolutely, there were statistically significant correlations among them.

  11. Methods and Piezoelectric Imbedded Sensors for Damage Detection in Composite Plates Under Ambient and Cryogenic Conditions

    NASA Technical Reports Server (NTRS)

    Engberg, Robert; Ooi, Teng K.

    2004-01-01

    New methods for structural health monitoring are being assessed, especially in high-performance, extreme environment, safety-critical applications. One such application is for composite cryogenic fuel tanks. The work presented here attempts to characterize and investigate the feasibility of using imbedded piezoelectric sensors to detect cracks and delaminations under cryogenic and ambient conditions. A variety of damage detection methods and different Sensors are employed in the different composite plate samples to aid in determining an optimal algorithm, sensor placement strategy, and type of imbedded sensor to use. Variations of frequency, impedance measurements, and pulse echoing techniques of the sensors are employed and compared. Statistical and analytic techniques are then used to determine which method is most desirable for a specific type of damage. These results are furthermore compared with previous work using externally mounted sensors. Results and optimized methods from this work can then be incorporated into a larger composite structure to validate and assess its structural health. This could prove to be important in the development and qualification of any 2" generation reusable launch vehicle using composites as a structural element.

  12. Quasi-simultaneous interaction method for solving 2D boundary layer flows over plates and airfoils

    NASA Astrophysics Data System (ADS)

    Bijleveld, H. A.; Veldman, A. E. P.

    2012-11-01

    This paper studies unsteady 2D boundary layer flows over dented plates and a NACA 0012 airfoil. An inviscid flow is assumed to exist outside the boundary layer and is solved iteratively with the boundary layer flow together with the interaction method until a matching solution is achieved. Hereto a quasi-simultaneous interaction method is applied, in which the integral boundary layer equations are solved together with an interaction-law equation. The interaction-law equation is an approximation of the external flow and based on thin-airfoil theory. It is an algebraic relation between the velocity and displacement thickness. The interaction-law equation ensures that the eigenvalues of the system of equations do not have a sign change and that no singularities occur. Three numerical schemes are used to solve the boundary layer flow with the interaction method. These are: a standard scheme, a splitting method and a characteristics solver. All schemes use a finite difference discretization. The three schemes yield comparable results for the simulations carried out. The standard scheme is deviating most from the splitting and characteristics solvers. The results show that the eigenvalues remain positive, even in separation. As expected, the addition of the interaction-law equation prevents a sign change of the eigenvalues. The quasi-simultaneous interaction scheme is applicable to the three numerical schemes tested.

  13. Robust scatter correction method for cone-beam CT using an interlacing-slit plate

    NASA Astrophysics Data System (ADS)

    Huang, Kui-Dong; Xu, Zhe; Zhang, Ding-Hua; Zhang, Hua; Shi, Wen-Long

    2016-06-01

    Cone-beam computed tomography (CBCT) has been widely used in medical imaging and industrial nondestructive testing, but the presence of scattered radiation will cause significant reduction of image quality. In this article, a robust scatter correction method for CBCT using an interlacing-slit plate (ISP) is carried out for convenient practice. Firstly, a Gaussian filtering method is proposed to compensate the missing data of the inner scatter image, and simultaneously avoid too-large values of calculated inner scatter and smooth the inner scatter field. Secondly, an interlacing-slit scan without detector gain correction is carried out to enhance the practicality and convenience of the scatter correction method. Finally, a denoising step for scatter-corrected projection images is added in the process flow to control the noise amplification The experimental results show that the improved method can not only make the scatter correction more robust and convenient, but also achieve a good quality of scatter-corrected slice images. Supported by National Science and Technology Major Project of the Ministry of Industry and Information Technology of China (2012ZX04007021), Aeronautical Science Fund of China (2014ZE53059), and Fundamental Research Funds for Central Universities of China (3102014KYJD022)

  14. Low density, microcellular, dopable, agar/gelatin foams for pulsed power experiments

    SciTech Connect

    McNamara, W.F.; Aubert, J.H.

    1997-04-01

    Low-density, microcellular foams prepared from the natural polymers agar and gelatin have been developed for pulsed-power physics experiments. Numerous experiments were supported with foams having densities at or below 10 mg/cm{sup 3}. For some of the experiments, the agar/gelatin foam was uniformly doped with metallic elements using soluble salts. Depending on the method of preparation, cell sizes were typically below 10 microns and for one process were below 1.0 micron.

  15. Free vibration analysis of plate assemblies using the dynamic stiffness method based on the higher order shear deformation theory

    NASA Astrophysics Data System (ADS)

    Kolarevic, Nevenka; Marjanović, Miroslav; Nefovska-Danilovic, Marija; Petronijevic, Mira

    2016-03-01

    This paper deals with the free vibration analysis of isotropic plate assemblies using the dynamic stiffness method (DSM) based on the Reddy's higher-order shear deformation theory (HSDT). Using the proposed method, the isotropic rectangular plate assemblies of non-uniform thickness and material properties can be analyzed. The proposed model does not have any restrictions regarding the boundary conditions or the frequency limitations. It enables free vibration analysis of both thin and thick plates, making it advantageous in comparison with the conventional finite element method (FEM) regarding the computational cost and the accuracy of the results. Three coupled Euler-Lagrange equations of motion based on the HSDT have been transformed into two uncoupled equations of motion introducing a boundary layer function. The dynamic stiffness matrix for a completely free rectangular plate element has been derived using the superposition and the projection method. The proposed numerical model has been applied in the free vibration analysis of rectangular plate assemblies. Along with the convergence study, the results for natural frequencies have been validated against the existing data from the literature, the previous results from the authors as well as the results obtained by using the finite element software Abaqus. Excellent agreement has been obtained. Finally, a variety of new results is provided as a benchmark for future investigations.

  16. Macroscale versus microscale methods for physiological analysis of biofilms formed in 96-well microtiter plates.

    PubMed

    Gomes, L C; Moreira, J M R; Miranda, J M; Simões, M; Melo, L F; Mergulhão, F J

    2013-12-01

    Microtiter plates with 96 wells have become one of the preferred platforms for biofilm studies mainly because they enable high-throughput assays. In this work, macroscale and microscale methods were used to study the impact of hydrodynamic conditions on the physiology and location of Escherichia coli JM109(DE3) biofilms formed in microtiter plates. Biofilms were formed in shaking and static conditions, and two macroscale parameters were assayed: the total amount of biofilm was measured by the crystal violet assay and the metabolic activity was determined by the resazurin assay. From the macroscale point of view, there were no statistically significant differences between the biofilms formed in static and shaking conditions. However, at a microscale level, the differences between both conditions were revealed using scanning electron microscopy (SEM). It was observed that biofilm morphology and spatial distribution along the wall were different in these conditions. Simulation of the hydrodynamic conditions inside the wells at a microscale was performed by computational fluid dynamics (CFD). These simulations showed that the shear strain rate was unevenly distributed on the walls during shaking conditions and that regions of higher shear strain rate were obtained closer to the air/liquid interface. Additionally, it was shown that wall regions subjected to higher shear strain rates were associated with the formation of biofilms containing cells of smaller size. Conversely, regions with lower shear strain rate were prone to have a more uniform spatial distribution of adhered cells of larger size. The results presented on this work highlight the wealth of information that may be gathered by complementing macroscale approaches with a microscale analysis of the experiments. PMID:24140575

  17. AN INTERCOMPARISON CF THE INTEGRATING PLATE AND THE LASER TRANSMISSION METHODS FOR DETERMINATION OF AEROSOL ABSORPTION COEFFICIENTS

    SciTech Connect

    Sadler, M.; Charlson, R.J.; Rosen, H.; Novakov, T.

    1980-07-01

    The absorption coefficients determined by the integrating plate method and the laser transmission method are found to be comparable and highly correlated. Furthermore, a high correlation is found between these absorption coefficients and the carbon content of the aerosol in urbanized regions.

  18. Influence of the ARC patterning method and annealing on the contact adhesion of Ni/Cu-plated solar cells

    NASA Astrophysics Data System (ADS)

    Baik, Jong Wook; Lee, Sang Hee; Lee, Doo Won; Lee, Soo Hong

    2016-05-01

    Ni/Cu two-step plating is a promising metallization technique because low contact resistance and improved contact adhesion can be achieved after the Ni annealing process. Also, narrow fingers, which are required for high-efficiency solar cells, can be formed by plating. However, the reliability of contact adhesion is still considered one obstacle to industrializing solar cells with plated metal contacts. In this experiment, the influence of ARC opening methods on plated contact adhesion was investigated because the roughnesses of the Si surfaces produced by using pico-second laser ablation and photolithography may be different. Also, the annealing process was conducted before and after plating Cu/Ag metal stacks. The sequence of the annealing can be significant for efficient production because plating is a wet process while annealing is a dry process. The contact adhesion was measured by using a peel-off test. The test was conducted on a 1.5-mm-wide by a 60 ~ 70- mm-long bus bar area. A 3.2-N/mm adhesion force was recorded as a highest average value along the bus bar.

  19. The Surface-Tension Method of Visually Inspecting Honeycomb-Core Sandwich Plates

    NASA Technical Reports Server (NTRS)

    Katzoff, Samuel

    1960-01-01

    When one face of a metal-honeycomb-core sandwich plate is heated or cooled relative to the other, heat transfer through the core causes the temperature on each face at the lines of contact with the core to be slightly different from that on the rest of the face. If a thin liquid film is applied to the face, the variation of surface tension with temperature causes the liquid to move from warmer to cooler areas and thus to develop a pattern corresponding to the temperature pattern on the face. Irregularities in the pattern identify the locations where the core is not adequately bonded to the face sheet. The pattern is easily observed when a fluorescent liquid is used and illumination is by means of ultraviolet light. Observation in ordinary light is also possible when a very deeply colored liquid is used. A method based on the use of a thermographic phosphor to observe the temperature pattern was found to be less sensitive than the surface-tension method. A sublimation method was found to be not only less sensitive but also far more troublesome.

  20. Multicycle Wilhelmy plate method for wetting properties, swelling and liquid sorption of wood.

    PubMed

    Moghaddam, Maziar Sedighi; Wålinder, Magnus E P; Claesson, Per M; Swerin, Agne

    2013-10-01

    A multicycle Wilhelmy plate method has been developed to investigate wetting properties, liquid sorption, and swelling of porous substrates such as wood. The use of the method is exemplified by studies of wood veneers of Scots pine sapwood and heartwood, which were subjected to repeated immersion and withdrawal in a swelling liquid (water) and in a nonswelling liquid (octane). The swelling liquid changes the sample dimensions during measurements, in particular its perimeter. This, in turn, influences the force registered. A model based on a linear combination of the measured force and final change in sample perimeter is suggested, and validated to elucidate the dynamic perimeter change of wood veneer samples. We show that pine heartwood and pine sapwood differ in several respects in their interaction with water. Pine heartwood showed (i) lower liquid uptake, (ii) lower swelling, (iii) higher contact angle, and (iv) lower level of dissolution of surface active components (extractives) than pine sapwood. We conclude that the method is also suitable for studying wetting properties of other porous and swellable materials. The wettability results were supported by surface chemical analysis using X-ray photoelectron spectroscopy, showing higher extractives and lignin content on heartwood than on sapwood surfaces.

  1. Using the finite element method to calculate sound transmission through bounded plates

    NASA Astrophysics Data System (ADS)

    Beshenkov, S. N.

    1990-04-01

    A finite element solution is obtained for the problem of sound transmission through a bounded plate mounted in an infinite absolutely rigid screen. Calculations are made of the soundproofing of quadratic and round plates. The convergence behavior of the iteration procedure used in the calculations is briefly discussed.

  2. Standardization of disk diffusion and agar dilution susceptibility tests for Neisseria gonorrhoeae: interpretive criteria and quality control guidelines for ceftriaxone, penicillin, spectinomycin, and tetracycline.

    PubMed Central

    Jones, R N; Gavan, T L; Thornsberry, C; Fuchs, P C; Gerlach, E H; Knapp, J S; Murray, P; Washington, J A

    1989-01-01

    A six-laboratory study developed a standardized method for determining the susceptibilities of Neisseria gonorrhoeae strains to penicillin, tetracycline, spectinomycin, and ceftriaxone. Three quality control organisms were also selected, and quality assurance guidelines were initially generated for the disk diffusion and agar dilution methods. The medium recommended for gonococcal susceptibility testing was GC agar with a defined "XV-like" supplement. The supplement should be free of cysteine, a component implicated in the inactivation of some newer beta-lactam compounds. Penicillin, tetracycline, spectinomycin, and ceftriaxone were stable in agar plates stored at 3 to 5 degrees C for at least 2 weeks. Numerous GC agar and drug disk lots were used during the trials without significant variation in test results. Several other gonococcal strains were recommended for additional medium quality assurance. The disk quality control zone limits were established for N. gonorrhoeae ATCC 49226 (formerly CDC F-18) and Staphylococcus aureus ATCC 25923. MIC quality control ranges were also developed for N. gonorrhoeae ATCC 49226 and S. aureus ATCC 29213. The interpretive criteria for penicillin were as follows: susceptibility, greater than or equal to 47 mm (diameter of inhibition zone) (less than or equal to 0.06 micrograms/ml [MIC]); resistance, less than or equal to 26 mm (greater than or equal to 2 micrograms/ml). For tetracycline they were as follows: susceptibility, greater than or equal to 38 mm (less than or equal to 0.25 microgram/ml); resistance, less than or equal to 30 mm (greater than or equal to 2 micrograms/ml). For spectinomycin they were as follows: susceptibility, >/= 18 mm (/= 128 micrograms/ml). For ceftriaxone susceptibility, the criterion was >/= 35 mm (

  3. Evaluation of the chromogenic agar chromID C. difficile.

    PubMed

    Eckert, Catherine; Burghoffer, Béatrice; Lalande, Valérie; Barbut, Frederic

    2013-03-01

    Three selective media (chromID C. difficile agar, taurocholate cycloserine cefoxitin agar [TCCA; homemade], and CLO medium) were compared from 406 stool samples of patients suspected of having Clostridium difficile infection. The sensitivities of chromID C. difficile agar at 24 h and 48 h, CLO medium, and TCCA were 74.1%, 87%, 85.2%, and 70.4%, respectively.

  4. Dry rehydratable film method for rapid enumeration of coliforms in foods (3M Petrifilm Rapid Coliform Count plate): collaborative study.

    PubMed

    Kinneberg, Karen M; Lindberg, Kathryn G

    2002-01-01

    A rehydratable dry-film plating method for coliforms in foods, the 3M Petrifilm Rapid Coliform Count plate method, was compared with the U.S. Food and Drug Administration's Bacteriological Analytical Manual method for nondairy foods and the American Public Health Association's Standard Methods for the Examination of Dairy Products (SMEDP) method for dairy foods. Six food types, vanilla ice cream, cheddar cheese, fresh refrigerated uncooked pasta, wheat flour, prepared frozen macaroni and cheese, and frozen hash browns, were analyzed for coliforms by 11 collaborating laboratories. For each food product tested, the collaborators received 8 blind samples consisting of a control sample and 3 levels of inoculated sample, each in duplicate. The mean log counts for the methods were comparable. The repeatability and reproducibility variances of the Petrifilm Rapid Coliform Count method at 14 and 24 h were not significantly different from those of the standard methods.

  5. Differential specificity of selective culture media for enumeration of pathogenic vibrios: advantages and limitations of multi-plating methods.

    PubMed

    Nigro, Olivia D; Steward, Grieg F

    2015-04-01

    Plating environmental samples on vibrio-selective chromogenic media is a commonly used technique that allows one to quickly estimate concentrations of putative vibrio pathogens or to isolate them for further study. Although this approach is convenient, its usefulness depends directly on how well the procedure selects against false positives. We tested whether a chromogenic medium, CHROMagar Vibrio (CaV), used alone (single-plating) or in combination (double-plating) with a traditional medium thiosulfate-citrate-bile-salts (TCBS), could improve the discrimination among three pathogenic vibrio species (Vibrio cholerae, Vibrio parahaemolyticus, and Vibrio vulnificus) and thereby decrease the number of false-positive colonies that must be screened by molecular methods. Assays were conducted on water samples from two estuarine environments (one subtropical, one tropical) in a variety of seasonal conditions. The results of the double-plating method were confirmed by PCR and 16S rRNA sequencing. Our data indicate that there is no significant difference in the false-positive rate between CaV and TCBS when using a single-plating technique, but determining color changes on the two media sequentially (double-plating) reduced the rate of false positive identification in most cases. The improvement achieved was about two-fold on average, but varied greatly (from 0- to 5-fold) and depended on the sampling time and location. The double-plating method was most effective for V. vulnificus in warm months, when overall V. vulnificus abundance is high (false positive rates as low as 2%, n=178). Similar results were obtained for V. cholerae (minimum false positive rate of 16%, n=146). In contrast, the false positive rate for V. parahaemolyticus was always high (minimum of 59%, n=109). Sequence analysis of false-positive isolates indicated that the majority of confounding isolates are from the Vibrionaceae family, however, members of distantly related bacterial groups were also able to

  6. Differential Quadrature and RAYLEIGH RITZ Methods to Determine the Fundamental Frequencies of Simply Supported Rectangular Plates with Linearly Varying Thickness

    NASA Astrophysics Data System (ADS)

    Kukreti, A. R.; Farsa, J.; Bert, C. W.

    1996-01-01

    In this paper, differential quadrature and Rayleigh-Ritz methods are presented for computation of the fundamental frequency of simply supported, homogeneous, isotropic, thin rectangular plates with the thickness tapering linearly in one direction. The complete analytical formulation and solution procedure is presented for both methods. Results obtained by these two methods are compared with available results in the literature and by the finite element method. Effects of the level of discretization, aspect and taper ratios are also presented.

  7. Quantitative assay for mutation in diploid human lymphoblasts using microtiter plates

    SciTech Connect

    Furth, E.A.; Thilly, W.G.; Penman, B.W.; Liber, H.L.; Rand, W.M.

    1981-01-01

    A microtiter plating technique which eliminates the need for soft agar and fibroblast feeder layers to determine the colony-forming ability of diploid human lymphoblast lines was described. The calculation of cloning efficiency is based on the Poisson distribution, and a statistical method for calculating confidence intervals is presented. This technique has been applied to the comcomitant examination of induced mutation at the putative loci for hypoxanthine guanine phosphoribosyl transferase, thymidine, kinase, and Na/sup +//K/sup +/ adenosine triphosphatase.

  8. Agar-Gel Precipitin Technique in Anthrax Antibody Determinations1

    PubMed Central

    Ray, John G.; Kadull, Paul J.

    1964-01-01

    A modification of the agar-gel precipitation inhibition technique of Thorne and Belton for detecting anthrax antibodies reduces inconsistency of visually determined end points on the same sera observed by different technicians. Determination of the minimal reacting concentrations of the anthrax antigen and antibody reagents, modifications of the visualization apparatus, methods for combining reagents, and length of incubation periods contribute to the ease of the end-point determinations and the uniformity of results. When compared with the previous technique, the modified procedure is less time-consuming while retaining satisfactory reproducibility, simplicity, specificity, and sensitivity. Images FIG. 1 FIG. 2 PMID:14201088

  9. Characteristic features and dye degrading capability of agar-agar gel immobilized manganese peroxidase.

    PubMed

    Bilal, Muhammad; Asgher, Muhammad; Shahid, Muhammad; Bhatti, Haq Nawaz

    2016-05-01

    Immobilization of enzymes has been regarded as an efficient approach to develop biocatalyst with improved activity and stability characteristics under reaction conditions. In the present study, purified manganese peroxidase (MnP) from Ganoderma lucidum IBL-05 was immobilized in agar-agar support using entrapment technique. Maximum immobilization yield was accomplished at 4.0% agar-agar gel. The immobilized MnP exhibited better resistance to changes in pH and temperature than the free enzyme, with optimal conditions being pH 6.0 and 50 °C. The kinetic parameters Km and Kcat/Km for free and entrapped MnP were calculated to be 65.6 mM and 6.99 M(-1) s(-1), and 82 mM and 8.15 M(-1) s(-1), respectively. Thermo-stability was significantly improved after immobilization. After 120 h, the insolubilized MnP retained its activity up to 71.9% and 60.3% at 30 °C and 40 °C, respectively. It showed activity until 10th cycle and retained 74.3% residual activity after 3th cycle. The effects of H2O2, ionic strength and potential inhibitors on activity of free and immobilized enzyme were investigated. Moreover, the decolorization of three structurally different dyes was monitored in order to assess the degrading capability of the entrapped MnP. The decolorization efficiencies for all the tested dyes were 78.6-84.7% after 12h. The studies concluded that the toxicity of dyes aqueous solutions was significantly reduced after treatment. The remarkable catalytic, thermo-stability and re-cycling features of the agar-agar immobilized MnP display a high potential for biotechnological applications. PMID:26854887

  10. Evaluation of dry sheet medium culture plate (Compactdry TC) method for determining numbers of bacteria in food samples.

    PubMed

    Mizuochi, S; Kodaka, H

    2000-05-01

    The Compactdry, a ready-to-use and self-diffusible dry medium sheet culture system, has been developed by the Nissui Pharmaceutical Co. Ltd. for enumerating bacteria in food. The Compactdry consists of special spread sheet with culture medium that is the same as standard method nutrients, a cold water-soluble gelling agent, and a unique plastic dish. The procedure for bacterial examination in a sample solution (1 ml) is to just inoculate a test solution into the center of the self-diffusible medium and incubate at 35 degrees C for 48 h. The Compactdry TC (CTC) for the enumeration of total aerobic bacteria from 97 food samples was compared with the standard plate count (SPC) method and 3M Petrifilm aerobic count plates (PAC). The correlation coefficients between the CTC and SPC method, the CTC and PAC, and the PAC and SPC method were 0.97, 0.99, and 0.97, respectively. The Compactdry system is useful for the enumeration of total aerobic bacteria in food and may be a possible suitable alternative to the conventional pour-plate or the Petrifilm plate methods.

  11. Volumetric topological analysis: a novel method for trabecular bone characterization on the continuum between plates and rods

    NASA Astrophysics Data System (ADS)

    Saha, Punam K.; Xu, Yan; Liang, Guoyuan; Duan, Hong

    2009-02-01

    Trabecular bone (TB) is a complex quasi-random network of interconnected struts and plates. TB constantly remodels to adapt dynamically to the stresses to which it is subjected (Wolff's Law). In osteoporosis, this dynamic equilibrium between bone formation and resorption is perturbed, leading to bone loss and structural deterioration, both increasing fracture risk. Bone's mechanical competence can only be partly explained by variations in bone mineral density, which led to the notion of bone structural quality. Previously, we developed digital topological analysis or DTA which classifies plates, rods, profiles, edges and junctions in a TB skeletal representation. Although the method has become quite popular, a major limitation is that DTA produces hard classifications only, failing to distinguish between narrow and wide plates. Here, we present a new method called volumetric topological analysis or VTA for quantification of regional topology in complex quasi-random TB networks. At each TB voxel, the method uniquely classifies the topology on the continuum between perfect plates and rods. Therefore, the method is capable of detecting early alterations of trabeculae from plates to rods according to the known etiology of osteoporotic bone loss. Here, novel ideas of geodesic distance transform, geodesic scale and feature propagation have been introduced and combined with DTA and fuzzy distance transform methods conceiving the new VTA technology. The method has been applied to MDCT and μCT images of a cadaveric distal tibia specimen and the results have been quantitatively evaluated. Specifically, intra- and inter-modality reproducibility of the method has been examined and the results are found very promising.

  12. The construction of airfoil pressure models by the plate method: Achievements, current research, technology development and potential applications

    NASA Technical Reports Server (NTRS)

    Lawing, P. L.

    1985-01-01

    A method of constructing airfoils by inscribing pressure channels on the face of opposing plates, bonding them together to form one plate with integral channels, and contour machining this plate to form an airfoil model is described. The research and development program to develop the bonding technology is described as well as the construction and testing of an airfoil model. Sample aerodynamic data sets are presented and discussed. Also, work currently under way to produce thin airfoils with camber is presented. Samples of the aft section of a 6 percent airfoil with complete pressure instrumentation including the trailing edge are pictured and described. This technique is particularly useful in fabricating models for transonic cryogenic testing, but it should find application in a wide ange of model construction projects, as well as the fabrication of fuel injectors, space hardware, and other applications requiring advanced bonding technology and intricate fluid passages.

  13. 3M Petrifilm Staph Express Count plate method for the enumeration of Staphylococcus aureus in selected dairy foods: collaborative study.

    PubMed

    Silbernagel, Karen M; Jechorek, Robert P; Carver, Charles N; Horter, Barbara L; Lindberg, Kathryn G

    2003-01-01

    The 3M Petrifilm Staph Express Count plate method was compared with AOAC Official Method 975.55 for the enumeration of Staphylococcus aureus in selected foods. Five foods--ice cream, raw milk, yogurt, whey powder, and cheese--were analyzed for S. aureus by 12 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample, a low inoculation level, a medium inoculation level, and a medium inoculation level with background flora, each in duplicate. The mean log10 counts for the methods were comparable for all 5 foods. The repeatability and reproducibility variances of the 24 h Petrifilm Staph Express Count plate method were similar to those of the 72 h standard method.

  14. Biological treatment of textile dyes by agar-agar immobilized consortium in a packed bed reactor.

    PubMed

    Patel, Yogesh; Gupte, Akshaya

    2015-03-01

    The decolorization of Acid Maroon V was investigated using bacterial consortium EDPA containing Enterobacter dissolvens AGYP1 and Pseudomonas aeruginosa AGYP2 immobilized in different entrapment matrices. The consortium displayed 96% removal of dye (100 mg/l) within 6 h when immobilized in agar-agar. Under optimum concentrations of agar-agar (3.0% w/v) and cell biomass (0.9 g% w/v), the consortium displayed decolorization for 18 successive batches of Acid Maroon V and also decolorized 14 other different textile dyes. A packed bed reactor under batch mode showed 89% decolorization of dye after 56 repetitive cycles. Under continuous flow mode, maximum color removal was achieved with bed length of 36 cm, hydraulic retention time of 2.66 h, and dye concentration of 100 mg/l. Additionally, the reactor decolorized relatively higher concentrations (100-2000 mg/l) of dye. The synthetic dye wastewater containing five textile dyes was decolorized 92% with 62% COD reduction using an immobilized consortium.

  15. Comparison of two optical-density-based methods and a plate count method for estimation of growth parameters of Bacillus cereus.

    PubMed

    Biesta-Peters, Elisabeth G; Reij, Martine W; Joosten, Han; Gorris, Leon G M; Zwietering, Marcel H

    2010-03-01

    Quantitative microbiological models predicting proliferation of microorganisms relevant for food safety and/or food stability are useful tools to limit the need for generation of biological data through challenge testing and shelf-life testing. The use of these models requires quick and reliable methods for the generation of growth data and estimation of growth parameters. Growth parameter estimation can be achieved using methods based on plate counting and methods based on measuring the optical density. This research compares the plate count method with two optical density methods, namely, the 2-fold dilution (2FD) method and the relative rate to detection (RRD) method. For model organism Bacillus cereus F4810/72, the plate count method and both optical density methods gave comparable estimates for key growth parameters. Values for the maximum specific growth rate (mu(max)) derived by the 2FD method and by the RRD method were of the same order of magnitude, but some marked differences between the two approaches were apparent. Whereas the 2FD method allowed the derivation of values for lag time (lambda) from the data, this was not possible with the RRD method. However, the RRD method gave many more data points per experiment and also gave more data points close to the growth boundary. This research shows that all three proposed methods can be used for parameter estimation but that the choice of method depends on the objectives of the research.

  16. Comparative analysis of cryopreservation methods in Chlamydomonas reinhardtii.

    PubMed

    Scarbrough, Chasity; Wirschell, Maureen

    2016-10-01

    Chlamydomonas is a model organism used for studies of many important biological processes. Traditionally, strains have been propagated on solid agar, which requires routine passaging for long-term maintenance. Cryopreservation of Chlamydomonas is possible, yet long-term viability is highly variable. Thus, improved cryopreservation methods for Chlamydomonas are an important requirement for sustained study of genetically defined strains. Here, we tested a commercial cryopreservation kit and directly compared it's effectiveness to a methanol-based method. We also tested thaw-back procedures comparing the growth of cells in liquid culture or on solid agar media. We demonstrated that methanol was the superior cryopreservation method for Chlamydomonas compared to the commercial kit and that post-thaw culture conditions dramatically affect viability. We also demonstrated that cryopreserved cells could be successfully thawed and plated directly onto solid agar plates. Our findings have important implications for the long-term storage of Chlamydomonas that can likely be extended to other algal species.

  17. Application of the HHT Method to the Non-contact Thickness Measurement of an Axially Moving Thin Plate

    NASA Astrophysics Data System (ADS)

    Wu, Yangfang; Lu, Qianqian; Xia, Chunlin; Ding, Fan

    2016-06-01

    Non-contact thickness measuring systems can be found in a wide spectrum of technologies. In this paper, Hilbert-Huang transform method is used to analyze the real time signals of a measuring system which includes two round conveyor strings carrying a thin plate, a solar wafer as a sample under test. The vibrations of moving strings and the plate, which are sensitive to moving speed and initial tension in the string, are introduced briefly; the relevant analyses should be helpful for the system design. Using EMD-based time-domain filtering and complementary method, thickness variations and error bands are estimated for different cases. The results show that HHT method as an adaptive time-frequency method, should be potential in measurement engineering applications.

  18. A high-throughput microtiter plate based method for the determination of peracetic acid and hydrogen peroxide.

    PubMed

    Putt, Karson S; Pugh, Randall B

    2013-01-01

    Peracetic acid is gaining usage in numerous industries who have found a myriad of uses for its antimicrobial activity. However, rapid high throughput quantitation methods for peracetic acid and hydrogen peroxide are lacking. Herein, we describe the development of a high-throughput microtiter plate based assay based upon the well known and trusted titration chemical reactions. The adaptation of these titration chemistries to rapid plate based absorbance methods for the sequential determination of hydrogen peroxide specifically and the total amount of peroxides present in solution are described. The results of these methods were compared to those of a standard titration and found to be in good agreement. Additionally, the utility of the developed method is demonstrated through the generation of degradation curves of both peracetic acid and hydrogen peroxide in a mixed solution. PMID:24260173

  19. A high-throughput microtiter plate based method for the determination of peracetic acid and hydrogen peroxide.

    PubMed

    Putt, Karson S; Pugh, Randall B

    2013-01-01

    Peracetic acid is gaining usage in numerous industries who have found a myriad of uses for its antimicrobial activity. However, rapid high throughput quantitation methods for peracetic acid and hydrogen peroxide are lacking. Herein, we describe the development of a high-throughput microtiter plate based assay based upon the well known and trusted titration chemical reactions. The adaptation of these titration chemistries to rapid plate based absorbance methods for the sequential determination of hydrogen peroxide specifically and the total amount of peroxides present in solution are described. The results of these methods were compared to those of a standard titration and found to be in good agreement. Additionally, the utility of the developed method is demonstrated through the generation of degradation curves of both peracetic acid and hydrogen peroxide in a mixed solution.

  20. Application of replica plating and computer analysis for rapid identification of bacteria in some foods. I. Identification scheme.

    PubMed

    Corlett, D A; Lee, J S; Sinnhuber, R O

    1965-09-01

    A method was devised and tested for a quantitative identification of microbial flora in foods. The colonies developing on the initial isolation plates were picked with sterile toothpicks and inoculated on a master plate in prearranged spacing and order. The growth on the master plates was then replicated on a series of solid-agar plates containing differential or selective agents. The characteristic growth and physiological responses of microbial isolates to penicillin, tylosin, vancomycin, streptomycin, chloramphenicol, neomycin, colistin, and to S S Agar, Staphylococcus Medium No. 110, and Potato Dextrose Agar were recorded, together with Gram reaction and cell morphology. This information was then fed into an IBM 1410 digital computer which grouped and analyzed each isolate into 10 microbial genera, or groups, according to the identification key. The identification scheme was established by use of reference culture studies and from the literature. This system was used to analyze the microbial flora in dover sole (Microstomus pacificus) and ground beef. The method described in this article enables one to examine large numbers of microbial isolates with simplicity. PMID:5325942

  1. Application of replica plating and computer analysis for rapid identification of bacteria in some foods. I. Identification scheme.

    PubMed

    Corlett, D A; Lee, J S; Sinnhuber, R O

    1965-09-01

    A method was devised and tested for a quantitative identification of microbial flora in foods. The colonies developing on the initial isolation plates were picked with sterile toothpicks and inoculated on a master plate in prearranged spacing and order. The growth on the master plates was then replicated on a series of solid-agar plates containing differential or selective agents. The characteristic growth and physiological responses of microbial isolates to penicillin, tylosin, vancomycin, streptomycin, chloramphenicol, neomycin, colistin, and to S S Agar, Staphylococcus Medium No. 110, and Potato Dextrose Agar were recorded, together with Gram reaction and cell morphology. This information was then fed into an IBM 1410 digital computer which grouped and analyzed each isolate into 10 microbial genera, or groups, according to the identification key. The identification scheme was established by use of reference culture studies and from the literature. This system was used to analyze the microbial flora in dover sole (Microstomus pacificus) and ground beef. The method described in this article enables one to examine large numbers of microbial isolates with simplicity.

  2. Improving agar electrospinnability with choline-based deep eutectic solvents.

    PubMed

    Sousa, Ana M M; Souza, Hiléia K S; Uknalis, Joseph; Liu, Shih-Chuan; Gonçalves, Maria P; Liu, LinShu

    2015-09-01

    Very recently our group has produced novel agar-based fibers by an electrospinning technique using water as solvent and polyvinyl alcohol (PVA) as co-blending polymer. Here, we tested the deep eutectic solvent (DES), (2-hydroxyethyl)trimethylammonium chloride/urea prepared at 1:2 molar ratio, as an alternative solvent medium for agar electrospinning. The electrospun materials were collected with an ethanol bath adapted to a previous electrospinning set-up. One weight percent agar-in-DES showed improved viscoelasticity and hence, spinnability, when compared to 1 wt% agar-in-water and pure agar nanofibers were successfully electrospun if working above the temperature of sol-gel transition (∼80 °C). By changing the solvent medium we decreased the PVA concentration (5 wt% starting solution) and successfully produced composite fibers with high agar contents (50/50 agar/PVA). Best composite fibers were formed with the 50/50 and 30/70 agar/PVA solutions. These fibers were mechanically resistant, showed tailorable surface roughness and diverse size distributions, with most of the diameters falling in the sub-micron range. Both nano and micro forms of agar fibers (used separately or combined) may have potential for the design of new and highly functional agar-based materials. PMID:26116384

  3. Comparison of plate counts, Petrifilm, dipslides, and adenosine triphosphate bioluminescence for monitoring bacteria in cooling-tower waters.

    PubMed

    Mueller, Sherry A; Anderson, James E; Kim, Byung R; Ball, James C

    2009-04-01

    Effective bacterial control in cooling-tower systems requires accurate and timely methods to count bacteria. Plate-count methods are difficult to implement on-site, because they are time- and labor-intensive and require sterile techniques. Several field-applicable methods (dipslides, Petrifilm, and adenosine triphosphate [ATP] bioluminescence) were compared with the plate count for two sample matrices--phosphate-buffered saline solution containing a pure culture of Pseudomonas fluorescens and cooling-tower water containing an undefined mixed bacterial culture. For the pure culture, (1) counts determined on nutrient agar and plate-count agar (PCA) media and expressed as colony-forming units (CFU) per milliliter were equivalent to those on R2A medium (p = 1.0 and p = 1.0, respectively); (2) Petrifilm counts were not significantly different from R2A plate counts (p = 0.99); (3) the dipslide counts were up to 2 log units higher than R2A plate counts, but this discrepancy was not statistically significant (p = 0.06); and (4) a discernable correlation (r2 = 0.67) existed between ATP readings and plate counts. For cooling-tower water samples (n = 62), (1) bacterial counts using R2A medium were higher (but not significant; p = 0.63) than nutrient agar and significantly higher than tryptone-glucose yeast extract (TGE; p = 0.03) and PCA (p < 0.001); (2) Petrifilm counts were significantly lower than nutrient agar or R2A (p = 0.02 and p < 0.001, respectively), but not statistically different from TGE, PCA, and dipslides (p = 0.55, p = 0.69, and p = 0.91, respectively); (3) the dipslide method yielded bacteria counts 1 to 3 log units lower than nutrient agar and R2A (p < 0.001), but was not significantly different from Petrifilm (p = 0.91), PCA (p = 1.00) or TGE (p = 0.07); (4) the differences between dipslides and the other methods became greater with a 6-day incubation time; and (5) the correlation between ATP readings and plate counts varied from system to system, was poor

  4. Agar Sediment Test for Assessing the Suitability of Organic Waste Streams for Recovering Nutrients by the Aquatic Worm Lumbriculus variegatus.

    PubMed

    Laarhoven, Bob; Elissen, H J H; Temmink, H; Buisman, C J N

    2016-01-01

    An agar sediment test was developed to evaluate the suitability of organic waste streams from the food industry for recovering nutrients by the aquatic worm Lumbriculus variegatus (Lv). The effects of agar gel, sand, and food quantities in the sediment test on worm growth, reproduction, and water quality were studied. Agar gel addition ameliorated growth conditions by reducing food hydrolysis and altering sediment structure. Best results for combined reproduction and growth were obtained with 0.6% agar-gel (20 ml), 10 g. fine sand, 40 g. coarse sand, and 105 mg fish food (Tetramin). With agar gel, ingestion and growth is more the result of addition of food in its original quality. Final tests with secondary potato starch sludge and wheat bran demonstrated that this test is appropriate for the comparison of solid feedstuffs and suspended organic waste streams. This test method is expected to be suitable for organic waste studies using other sediment dwelling invertebrates.

  5. Agar Sediment Test for Assessing the Suitability of Organic Waste Streams for Recovering Nutrients by the Aquatic Worm Lumbriculus variegatus

    PubMed Central

    Laarhoven, Bob; Elissen, H. J. H.; Temmink, H.; Buisman, C. J. N.

    2016-01-01

    An agar sediment test was developed to evaluate the suitability of organic waste streams from the food industry for recovering nutrients by the aquatic worm Lumbriculus variegatus (Lv). The effects of agar gel, sand, and food quantities in the sediment test on worm growth, reproduction, and water quality were studied. Agar gel addition ameliorated growth conditions by reducing food hydrolysis and altering sediment structure. Best results for combined reproduction and growth were obtained with 0.6% agar-gel (20 ml), 10 g. fine sand, 40 g. coarse sand, and 105 mg fish food (Tetramin). With agar gel, ingestion and growth is more the result of addition of food in its original quality. Final tests with secondary potato starch sludge and wheat bran demonstrated that this test is appropriate for the comparison of solid feedstuffs and suspended organic waste streams. This test method is expected to be suitable for organic waste studies using other sediment dwelling invertebrates. PMID:26937632

  6. Agar Sediment Test for Assessing the Suitability of Organic Waste Streams for Recovering Nutrients by the Aquatic Worm Lumbriculus variegatus.

    PubMed

    Laarhoven, Bob; Elissen, H J H; Temmink, H; Buisman, C J N

    2016-01-01

    An agar sediment test was developed to evaluate the suitability of organic waste streams from the food industry for recovering nutrients by the aquatic worm Lumbriculus variegatus (Lv). The effects of agar gel, sand, and food quantities in the sediment test on worm growth, reproduction, and water quality were studied. Agar gel addition ameliorated growth conditions by reducing food hydrolysis and altering sediment structure. Best results for combined reproduction and growth were obtained with 0.6% agar-gel (20 ml), 10 g. fine sand, 40 g. coarse sand, and 105 mg fish food (Tetramin). With agar gel, ingestion and growth is more the result of addition of food in its original quality. Final tests with secondary potato starch sludge and wheat bran demonstrated that this test is appropriate for the comparison of solid feedstuffs and suspended organic waste streams. This test method is expected to be suitable for organic waste studies using other sediment dwelling invertebrates. PMID:26937632

  7. Effect of Soybean Casein Digest Agar Lot on Number of Bacillus stearothermophilus Spores Recovered †

    PubMed Central

    Pflug, I. J.; Smith, Geraldine M.; Christensen, Ronald

    1981-01-01

    In recent years it has become increasingly apparent that Bacillus stearothermophilus spores are affected by various environmental factors that influence the performance of the spores as biological indicators. One environmental factor is the recovery medium. The effect of different lots of commercial soybean casein digest agar on the number of colony-forming units per plate was examined in two series of experiments: (i) several lots of medium from two manufacturers were compared in single experiments, and (ii) paired media experiments with four lots of medium were carried out and yielded three-point survivor curves. The results demonstrate that commercial soybean casein digest agar is variable on a lot-to-lot basis. The variation was lowest when recovering unheated or minimally heated spores and increased greatly with the severity of heating. PMID:16345822

  8. Comparison of the compact dry TC method with the standard pour plate method (AOAC official method 966.23) for determining aerobic colony counts in food samples: Performance-tested method.

    PubMed

    Kodaka, Hidemasa; Mizuochi, Shingo; Teramura, Hajime; Nirazuka, Tadanobu

    2005-01-01

    Compact Dry TC qualifies as a rapid method kit for determining aerobic colony counts in foods. The plates are presterilized and contain culture medium and a cold-soluble gelling agent. The medium is rehydrated by inoculating 1 mL diluted sample into the center of the self-diffusible medium and allowing the solution to diffuse by capillary action. The plates can then be incubated and the colonies counted without any additional steps. The Compact Dry TC method was validated with 5 different raw meats. The performance tests were conducted at 35 degrees and 30 degrees C. In all required performance studies, no apparent differences were observed between the Compact Dry TC method and the Standard Pour Plate method (AOAC Official Method 966.23) for the detection level of aerobic microorganisms. For the accuracy claim (n = 60), a correlation factor of r2(35) = 0.9977 (35 degrees C) and r2(30) = 0.9932 (30 degrees C) could be assigned, as stated in the application for "Performance Tested Method." Quality consistency and storage robustness studies, showed no significant variations in plate count results with different production lots or plates of diverse storage age.

  9. Experimental modal analysis of an aluminum rectangular plate by use of the slope-assisted BOTDA method

    NASA Astrophysics Data System (ADS)

    Minardo, A.; Coscetta, A.; Pirozzi, S.; Bernini, R.; Zeni, L.

    2013-12-01

    We report an experimental modal analysis of an aluminum rectangular plate (50 cm×30 cm×0.3 cm), carried out by use of a Brillouin optical time-domain analysis (BOTDA) sensor operating in the slope-assisted configuration, i.e. at a fixed pump-probe frequency shift. Strain measurements were acquired along an optical fiber attached to the structure, at a maximum acquisition rate of 250 Hz, a spatial resolution of 30 cm and a sampling distance of 5 cm in both x- and y-directions. A sequence of dynamic tests, aimed to evaluate the resonant frequencies and strain modal shapes of the structure, were performed on the plate for various boundary conditions (plate clamped with four, three or two bolts). Comparison with finite element method (FEM) analysis and dynamic strain measurements with strain gauges shows that Brillouin based distributed sensors can be usefully employed to perform the modal analysis of a vibrating structure, even if the spatial resolution is comparable with the plate dimensions.

  10. Comparison of 3M Petrifilm Aerobic Count Plates to standard plating methodology for use with AOAC antimicrobial efficacy methods 955.14, 955.15, 964.02, and 966.04 as an alternative enumeration procedure: collaborative study.

    PubMed

    Nelson, Maria T; LaBudde, Robert A; Tomasino, Stephen F; Pines, Rebecca M

    2013-01-01

    A multilaboratory study was conducted to determine the equivalence of the 3M Petrifilm Aerobic Count Plate and standard plating methodology for measuring viable bacteria and spores recovered from hard-surface carriers (stainless steel and porcelain), also known as "control carrier counts," used in AOAC antimicrobial efficacy test methods. Six laboratories participated in the study in which carriers inoculated with Staphylococcus aureus, Pseudomonas aeruginosa, Salmonella enterica, and spores of Bacillus subtilis were evaluated using 3M Petrifilm Aerobic Count (AC) plates and standard plating side-by-side. The data were analyzed using a matched-pair t-test to determine the between-method effect with confidence intervals. For all test organisms pooled across all laboratories, the mean difference in log10 concentration between the standard plate count method and 3M Petrifilm AC Plates was -0.012, with a 95% confidence interval of (-0.090, +0.066), which was well within the -0.5, +0.5 interval established as the acceptance criterion. The between-carrier SD averaged 0.139; the between-replicate SD was 0.050. The carrier reproducibility, given that a single replicate per carrier is done, was estimated to be 0.148. Although differences were seen in the final concentrations of the test organisms among laboratories, there were no statistical differences between the enumeration methods. Based on the results from this study, 3M Petrifilm AC Plates are equivalent to standard plating methodology and can be used as an alternative procedure for the enumeration of test organisms used in AOAC Methods 955.14, 955.15, 964.02, and 966.04.

  11. Evaluation of agar-based medium with sheep sera for testing of drug susceptibility of Mycobacterium tuberculosis to Isoniazid, Rifampin, Ethambutol, and Streptomycin.

    PubMed

    Coban, Ahmet Yilmaz; Uzun, Meltem; Bozdogan, Bulent

    2013-12-01

    The performance of sheep sera instead of sheep blood in agar-based media was investigated for susceptibility testing of Mycobacterium tuberculosis against primary drugs. The levels of agreement between agar-based medium supplemented with sheep sera and the proportion method on Middlebrook 7H11 agar as the reference method for determining susceptibility to isoniazid (INH), rifampin (RIF), ethambutol (EMB), and streptomycin (STR) were 98.4, 98.4, 95.3, and 100%, respectively.

  12. AgarTrap-mediated genetic transformation using intact gemmae/gemmalings of the liverwort Marchantia polymorpha L.

    PubMed

    Tsuboyama-Tanaka, Shoko; Kodama, Yutaka

    2015-03-01

    The dioecious liverwort, Marchantia polymorpha L., is an emerging model plant. Various molecular biological techniques have been optimized for M. polymorpha for the past several years, and recently we reported a simplified Agrobacterium-mediated transformation method using sporelings (immature thalli from spores) of M. polymorpha. This method, termed AgarTrap (Agar-utilized Transformation with Pouring Solutions), completed by exchanging appropriate solutions on a single Petri dish to produce a sufficient number of independent transgenic sporelings. However, because spores are produced by crosses between males and females, the genetic backgrounds of resulting transgenic sporelings are not uniform. To easily produce transgenic liverworts with a uniform genetic background using AgarTrap, we developed an AgarTrap-mediated transformation method using intact gemmae/gemmalings produced by asexual reproduction. Using AgarTrap with male and female gemmae/gemmalings produced a sufficient number of independent transgenic gemmalings with uniform genetic backgrounds. The optimized transformation efficiencies were approximately 30 and 50 % in males and females, respectively. As with AgarTrap using sporelings, AgarTrap using intact gemmae/gemmalings will be useful in promoting studies of the molecular biology of M. polymorpha. PMID:25663453

  13. An equilibrium method for prediction of transverse shear stresses in a thick laminated plate

    NASA Technical Reports Server (NTRS)

    Chaudhuri, R. Z.

    1986-01-01

    First two equations of equilibrium are utilized to compute the transverse shear stress variation through thickness of a thick laminated plate after in-plane stresses have been computed using an assumed quadratic displacement triangular element based on transverse inextensibility and layerwise constant shear angle theory (LCST). Centroid of the triangle is the point of exceptional accuracy for transverse shear stresses. Numerical results indicate close agreement with elasticity theory. An interesting comparison between the present theory and that based on assumed stress hybrid finite element approach suggests that the latter does not satisfy the condition of free normal traction at the edge. Comparison with numerical results obtained by using constant shear angle theory suggests that LCST is close to the elasticity solution while the CST is closer to classical (CLT) solution. It is also demonstrated that the reduced integration gives faster convergence when the present theory is applied to a thin plate.

  14. Method for determining D-xylose in copper-plating solutions

    SciTech Connect

    Feemster, H.C.

    1981-04-01

    A modified colormetric procedure for the determination of low concentrations of D-xylose in copper sulfate-sulfuric acid plating baths is described. The D-xylose is added to the copper solutions to eliminate gas entrapment in the finished copper deposit. Determinations were made at 620 nm with concentrations between 0.01 to 0.1 mg D-xylose per ml. The system obeys Beer's Law at these concentrations.

  15. Comparison of enrichment and plating media for isolation of Yersinia.

    PubMed

    Cox, N A; Bailey, J S; Del Corral, F; Shotts, E B

    1990-04-01

    Yersinia enterocolitica (Serotypes 0:3 or 0:8), Yersinia frederiksenii, Yersinia kristensenii, or Yersinia intermedia along with 10(8) cells of each of three extraneous organisms (Escherichia coli, Enterobacter aerogenes, Pseudomonas fragi), all commonly found on market poultry, were inoculated into five enrichment media followed by streaking onto 11 plating media to determine the most-efficacious combinations for future surveys or assessment studies. For Yersinia enterocolitica (0:8), infrequent recoveries were made using yeast extract-rosebengal-bile oxalate sorbose broth and phosphate-buffered saline (4 C) followed by plating onto pectin, DNase-Tween 80 (polyoxyethylene sorbitan monooleate)-sorbitol, MacConkey-Tween 80, or cefsulodin-irgasan-novobiocin (CIN) agars. With Y. enterocolitica (0:3), recoveries were most frequently made using phosphate-buffered saline, sorbitol bile (incubated for 17 days) and yeast extract-rosebengal-bile oxalate sorbose broth followed by plating onto pectin, CIN, bismuth sulfite (Difco Laboratories, Detroit, MI), or modified Rimler-Shotts agar. For Y. frederiksenii, Y. kristensenii, and Y. intermedia, incubation in sorbitol bile for 17 days or in yeast extract-rosebengal-bile oxalate sorbose broth, followed by plating onto CIN, pectin, DNase-Tween/80-sorbitol, cellobiose-arginine-lysine agar, or MacConkey-Tween 80 agar yielded the most-frequent recoveries. Overall, the CIN and pectin agars performed best for the recovery of the Yersinia bacterium; the modified selenite broth and the bismuth-sulfite plating agars were unsatisfactory in the present study.

  16. Gel microbead cultivation with a subenrichment procedure can yield better bacterial cultivability from a seawater sample than standard plating method

    NASA Astrophysics Data System (ADS)

    Ji, Shiqi; Zhao, Rui; Yin, Qi; Zhao, Yuan; Liu, Chenguang; Xiao, Tian; Zhang, Xiaohua

    2012-03-01

    A gel microbead (GMD) cultivation method was employed to cultivate microorganisms from an amphioxus breeding zone in Qingdao, P. R. China. The culture results were compared with those by standard plating method. In the GMD-based method, the microcolony-forming GMDs were sorted by fluorescence-activated cell sorting (FACS). To further get pure cultures, a subsequent enrichment culture and a streaking purification procedure were conducted on marine R2A medium. Eighty bacterial strains isolated by the GMD-based method were randomly selected for sequencing. These isolates belonged to Alphaproteobacteria (33%), Gammaproteobacteria (44%), Bacteroidetes (11%), Actinobacteria (5%), Firmicutes (5%), Epsilonproteobacteria (1%), and Verrucomicrobia (1%), the last two groups being usually difficult to culture. The 16S rRNA gene sequences revealed a diverse community with 91.1%-100% of the bacterial rRNAs similarities. Thirteen strains were sharing 16S rRNA gene sequence which was less than 97% similar to any other rRNA genes currently deposited in TYP16S database. Seventy isolates derived from the standard plating method fell into 4 different taxonomic groups: Alphaproteobacteria (9%), Gammaproteobacteria (81%), Bacteroidetes (7%) and Firmicutes (3%) with a 16S rRNA gene sequence similarities between 95.8%-100%, in which only 3 strains were sharing 16S rRNA gene sequence of less than 97%. The results indicated that the GMD-based method with subenrichment culture yielded more taxonomic groups and more novel microbial strains, including members of previously rarely cultured groups, when compared with the standard plating method, and that this method markedly improved the bacterial cultivability.

  17. A method for measuring skin friction drag on a flat plate in contaminated gas flows

    NASA Technical Reports Server (NTRS)

    Oetting, R. B.; Patterson, G. K.

    1984-01-01

    A technique for measuring friction drag in turbulent gas and gas/particle flows over flat plates is presented, and preliminary results are reported. A 0.25-in.-thick 72 x 6-in. Al plate is suspended by six horizontal support air bearings and four vertical alignment air bearings between fixed dummy plates and leading-edge and trailing-edge fairings in the 32-in.-high 48-in.-wide 11-ft-long test section of a closed-circuit atmospheric wind tunnel operating at 50-150 ft/sec. Particles of Fe and Al oxides of diameter 20-150 microns and density up to 0.3 lb particles per lb air are injected via a 6 x 0.167-in. nozzle; turbulence is induced by a roughened section of the leading-edge fairing; and friction drag is measured using a load-cell pressure transducer. Sample results are shown in a graph, demonstrating good agreement with theoretical drag calculations.

  18. Antimicrobial and physical-mechanical properties of agar-based films incorporated with grapefruit seed extract.

    PubMed

    Kanmani, Paulraj; Rhim, Jong-Whan

    2014-02-15

    The use of synthetic petroleum based packaging films caused serious environmental problems due to their difficulty in recycling and poor biodegradability. Therefore, present study was aimed to develop natural biopolymer-based antimicrobial packaging films as an alternative for the synthetic packaging films. As a natural antimicrobial agent, grapefruit seed extract (GSE) has been incorporated into agar to prepare antimicrobial packaging film. The films with different concentrations of GSE were prepared by a solvent casting method and the resulting composite films were examined physically and mechanically. In addition, the films were characterized by FE-SEM, XRD, FT-IR and TGA. The incorporation of GSE caused increase in color, UV barrier, moisture content, water solubility and water vapor permeability, while decrease in surface hydrophobicity, tensile strength and elastic modulus of the films. As the concentration of GSE increased from 0.6 to 13.3 μg/mL, the physical and mechanical properties of the films were affected significantly. The addition of GSE changed film microstructure of the film, but did not influence the crystallinity of agar and thermal stability of the agar-based films. The agar/GSE films exhibited distinctive antimicrobial activity against three test food pathogens, such as Listeria monocytogenes, Bacillus cereus and Escherichia coli. These results suggest that agar/GSE films have potential to be used in an active food packaging systems for maintaining food safety and extending the shelf-life of the packaged food. PMID:24507339

  19. Preparation and characterization of agar/clay nanocomposite films: the effect of clay type.

    PubMed

    Rhim, Jong-Whan; Lee, Soo-Bin; Hong, Seok-In

    2011-04-01

    Agar-based nanocomposite films with different types of nanoclays, such as Cloisite Na+, Cloisite 30B, and Cloisite 20A, were prepared using a solvent casting method, and their tensile, water vapor barrier, and antimicrobial properties were tested. Tensile strength (TS), elongation at break (E), and water vapor permeability (WVP) of control agar film were 29.7±1.7 MPa, 45.3±9.6%, and (2.22±0.19)×10(-9) g·m/m2·s·Pa, respectively. All the film properties tested, including transmittance, tensile properties, WVP, and X-ray diffraction patterns, indicated that Cloisite Na+ was the most compatible with agar matrix. TS of the nanocomposite films prepared with 5% Cloisite Na+ increased by 18%, while WVP of the nanocomposite films decreased by 24% through nanoclay compounding. Among the agar/clay nanocomposite films tested, only agar/Cloisite 30B nanocomposite film showed a bacteriostatic function against Listeria monocytogenes.

  20. Evaluation of the antibacterial effects of vancomycin hydrochloride released from agar-gelatin-bioactive glass composites.

    PubMed

    Rivadeneira, Josefina; Di Virgilio, Ana Laura; Audisio, M Carina; Boccaccini, Aldo R; Gorustovich, Alejandro A

    2015-01-13

    The aim of this work was to evaluate the perfomance of agar-gelatin (AG) composites and AG-containing 45S5 bioactive glass (BG) microparticles (AGBG) in relation to their water uptake capacity, sustained release of a drug over time, and antibacterial effects. The composites were fabricated by the gel-casting method. To impart the local drug release capacity, vancomycin hydrochloride (VC) was loaded in the composites in concentrations of 0.5 and 1 mg ml(-1). VC release was assessed in distilled water at 37 °C up to 72 h and quantified spectrophotometrically. The antibacterial activity of composites was evaluated by the inhibition zone test and the plate count method. The experiments were performed in vitro up to 48 h on three staphylococcus strains: Staphylococcus aureus ATCC29213, S. aureus ATCC6538 and Staphylococcus epidermidis ATCC12228. The results showed that the addition of BG to AG composites did not affect the degree of water uptake. The release of VC was significantly affected by the presence of BG. VC release was higher from AGBGVC films than from AGVC ones over prolonged incubation times. Bacterial inhibition zones were found around the composites. The halos were larger when the cells were put in contact with AGVC composites than when they were put in contact with AGBGVC ones. Nevertheless, the viable count method demonstrated that the composites inhibited Staphylococcus cell growth with no statistical differences. In conclusion, the addition of BG did not reflect an improvement in the parameters studied. On the other hand, composites loaded with VC would have a role in prophylaxis against bacterial infection.

  1. An approximate semi-analytical method for prediction of interlaminar shear stresses in an arbitrarily laminated thick plate

    NASA Technical Reports Server (NTRS)

    Chaudhuri, Reaz A.; Seide, Paul

    1987-01-01

    An approximate semianalytical method for determination of interlaminar shear stress distribution through the thickness of an arbitrarily laminated thick plate has been presented. The method is based on the assumptions of transverse inextensibility and layerwise constant shear angle theory (LCST) and utilizes an assumed quadratic displacement potential energy based finite element method (FEM). Centroid of the triangular surface has been proved from a rigorous mathematical point of view (Aubin-Nitsche theory), to be the point of exceptional accuracy for the interlaminar shear stresses. Numerical results indicate close agreement with the available three-dimensional elasticity theory solutions. A comparison between the present theory and that due to an assumed stress hybrid FEM suggest that the (normal) traction-free-edge condition is not satisfied in the latter approach. Furthermore, the present paper is the first to present the results for interlaminar shear stresses in a two-layer thick square plate of balanced unsymmetric angle-ply construction. A comparison with the recently proposed Equilibrium Method (EM) indicates the superiority of the present method, because the latter assures faster convergence as well as simultaneous vanishing of the transverse shear stresses on both of the exposed surfaces of the laminate. Superiority of the present method over the EM, in the case of a symmetric laminate, is limited to faster convergence alone. It has also been demonstrated that the combination of the present method and the reduced (quadratic order) numerical integration scheme yields convergence of the interlaminar shear stresses almost as rapidly as that of the nodal displacements, in the case of a thin plate.

  2. A correlation method to predict the surface pressure distribution on an infinite plate from which a jet is issuing. [effects of a lifting jet

    NASA Technical Reports Server (NTRS)

    Perkins, S. C., Jr.; Menhall, M. R.

    1978-01-01

    A correlation method to predict pressures induced on an infinite plate by a jet issuing from the plate into a subsonic free stream was developed. The complete method consists of an analytical method which models the blockage and entrainment properties of the jet and a correlation which accounts for the effects of separation. The method was developed for jet velocity ratios up to ten and for radial distances up to five diameters from the jet. Correlation curves and data comparisons are presented for jets issuing normally from a flat plate with velocity ratios one to twelve. Also, a list of references which deal with jets in a crossflow is presented.

  3. An optimal open/closed-loop control method with application to a pre-stressed thin duralumin plate

    NASA Astrophysics Data System (ADS)

    Nadimpalli, Sruthi Raju

    The excessive vibrations of a pre-stressed duralumin plate, suppressed by a combination of open-loop and closed-loop controls, also known as open/closed-loop control, is studied in this thesis. The two primary steps involved in this process are: Step (I) with an assumption that the closed-loop control law is proportional, obtain the optimal open-loop control by direct minimization of the performance measure consisting of energy at terminal time and a penalty on open-loop control force via calculus of variations. If the performance measure also involves a penalty on closed-loop control effort then a Fourier based method is utilized. Step (II) the energy at terminal time is minimized numerically to obtain optimal values of feedback gains. The optimal closed-loop control gains obtained are used to describe the displacement and the velocity of open-loop, closed-loop and open/closed-loop controlled duralumin plate.

  4. Experience of the Indirect Neutron Radiography Method Based on the X-ray Imaging Plate at CARR

    NASA Astrophysics Data System (ADS)

    Wei, Guohai; Han, Songbai; Wang, Hongli; He, Linfeng; Wang, Yu; Wu, Meimei; Liu, Yuntao; Chen, Dongfeng

    Indirect neutron radiography (INR) experiments by X-ray imaging plate were carried out at the China Advanced Research Reactor (CARR). The key experiment parameters were optimized, especially the exposure time of the neutron converter andimaging plate. The optimized total exposure time is 37.25 min, it is two-fifths of the timebased on the film method under the same experimental conditions. The qualitative and quantitativeinspections were tested with dummy nuclear fuel rods and a water temperaturesensor ofa motor vehicle. The spring in the sensor and the defects of the dummy fuel rod's pellets can be qualitatively detected. The thickness of the tape at one position on the cladding of the dummy nuclear fuel rodwas quantitatively calculated to be 9.57 layers with the relative error of ±4.3%.

  5. [Presumptive identification of Candida spp. and other clinically important yeasts: usefulness of Brilliance Candida Agar].

    PubMed

    Alfonso, Claudia; López, Mónica; Arechavala, Alicia; Perrone, María Del Carmen; Guelfand, Liliana; Bianchi, Mario

    2010-06-30

    Fungal infections caused by yeasts have increased during the last decades and invasive forms represent a serious problem for human health. Candida albicans is the species most frequently isolated from clinical samples. However, other emerging yeast pathogens are increasingly responsible for mycotic infections, and some of them are resistant to some antifungal drugs. Consequently, it is necessary to have methods that can provide a rapid presumptive identification at species level. Numerous chromogenic agar media have been shown to be of value as diagnostic tools. We have compared a chromogenic medium, Brilliance Candida Agar, with CHROMagar Candida, the chromogenic medium most used in our country. A multicentre study was conducted in 16 Hospitals belonging to the Mycology Net of Buenos Aires City Government. A total of 240 yeast isolates were included in this research. The new chromogenic agar showed results very similar to those obtained with CHROMagar Candida.

  6. Removal of 2,4-dinitrotoluene from concrete using bioremediation, agar extraction, and photocatalysis.

    PubMed

    Phutane, S R; Renner, J N; Nelson, S L; Seames, W S; Páca, J; Sundstrom, T J; Kozliak, E I

    2007-01-01

    Three methods, i.e. bioremediation by application of bacteria-laden agar, physical absorption of DNT by agar, or illumination by UV light were evaluated for the removal of 2,4-dinitrotoluene (DNT) from building-grade concrete. DNT biodegradation by Pseudomonas putida TOD was turned "on" and "off" by using toluene as a co-substrate thus allowing for rate-limiting step assessment. Bioremediation efficiency can be > 95-97% in 5-7 d if the process occurs at optimum growth temperature with the biological processes appearing to be rate-limiting. Sterile agar can remove up to 80% of DNT from concrete thus allowing DNT desorption and biodegradation to be conducted separately. Photoremediation results in 50% DNT removal in 9-12 d with no further removal, most likely due to mass transfer limitations.

  7. Homogeneous Matrix Deposition on Dried Agar for MALDI Imaging Mass Spectrometry of Microbial Cultures

    NASA Astrophysics Data System (ADS)

    Hoffmann, Thomas; Dorrestein, Pieter C.

    2015-11-01

    Matrix deposition on agar-based microbial colonies for MALDI imaging mass spectrometry is often complicated by the complex media on which microbes are grown. This Application Note demonstrates how consecutive short spray pulses of a matrix solution can form an evenly closed matrix layer on dried agar. Compared with sieving dry matrix onto wet agar, this method supports analyte cocrystallization, which results in significantly more signals, higher signal-to-noise ratios, and improved ionization efficiency. The even matrix layer improves spot-to-spot precision of measured m/z values when using TOF mass spectrometers. With this technique, we established reproducible imaging mass spectrometry of myxobacterial cultures on nutrient-rich cultivation media, which was not possible with the sieving technique.

  8. Isolation and characterization of agar-digesting Vibrio species from the rotten thallus of Gracilariopsis heteroclada Zhang et Xia.

    PubMed

    Martinez, Joval N; Padilla, Philip Ian P

    2016-08-01

    Gracilariopsis heteroclada Zhang et Xia (Gracilariaceae, Rhodophyta) is one of the most studied marine seaweeds due to its economic importance. This has been cultivated extensively on commercial scale in the Philippines and other Asian countries. However, sustainable production of G. heteroclada in the Philippines could not be maximized due to the occurrence of rotten thallus disease. Thus, isolation and characterization of agar-digesting bacteria from the rotten thalli of G. heteroclada was conducted. A total of seven representative bacterial isolates were randomly selected based on their ability to digest agar as evidenced by the formation of depressions around the bacterial colonies on nutrient agar plates supplemented with 1.5% NaCl and liquefaction of agar. Gram-staining and biochemical characterization revealed that isolates tested were gram-negative rods and taxonomically identified as Vibrio parahaemolyticus (86-99.5%) and Vibrio alginolyticus (94.2-97.7%), respectively. It is yet to be confirmed whether these agar-digesting vibrios are involved in the induction and development of rotten thallus disease in G. heteroclada in concomitance with other opportunistic bacterial pathogens coupled with adverse environmental conditions. PMID:27285614

  9. Assessment of Etest as an alternative to agar dilution for antimicrobial susceptibility testing of Neisseria gonorrhoeae.

    PubMed

    Liu, Hsi; Taylor, Thomas H; Pettus, Kevin; Trees, David

    2014-05-01

    We studied whether the Etest can be used as an alternative to agar dilution to determine antimicrobial susceptibilities of ceftriaxone, cefixime, and cefpodoxime in Neisseria gonorrhoeae surveillance. One hundred fifteen clinical and laboratory isolates of N. gonorrhoeae were tested following the Clinical Laboratory Improvement Amendments (CLIA)-approved CLSI standard agar dilution method and, separately, by the Etest according to the manufacturer's recommendations. The MICs were determined and compared. Ten laboratory-generated mutants were used to simulate substantially nonsusceptible specimens. The Etest and agar dilution methods were well correlated. Statistical tests produced regression R2 values of 88%, 82%, and 85% and Pearson correlation coefficients of 92%, 91%, and 92% for ceftriaxone, cefixime, and cefpodoxime, respectively. When paired comparisons were made, the two tests were 88.7%, 80%, and 87% within 1 log2 dilution from each other for ceftriaxone, cefixime, and cefpodoxime, respectively. The within-2-log2 agreements were 99.1%, 98.3%, and 94.8% for ceftriaxone, cefixime, and cefpodoxime, respectively. Notwithstanding the good correlations and the within-2-log2 general agreement, the Etest results produced slightly lower MICs than the agar dilution results. In conclusion, we found that the Etest can be effectively used as an alternative to agar dilution testing to determine the susceptibility of N. gonorrhoeae to ceftriaxone, cefixime, and cefpodoxime, although we recommend further research into extremely resistant isolates. For isolates within the typical range of clinical MICs, reexamination of the Etest interpretation of susceptible and nonsusceptible categories would likely allow for successful transition from agar dilution to the Etest.

  10. Comparison of inhibitory mold agar to Sabouraud dextrose agar as a primary medium for isolation of fungi.

    PubMed

    Scognamiglio, Theresa; Zinchuk, Riva; Gumpeni, Pramod; Larone, Davise H

    2010-05-01

    Clinical specimens cultured on two selective fungal media, inhibitory mold agar (IMA) and Sabouraud dextrose agar (SDA), were compared with respect to recovery of fungi. Of the 840 fungal isolates recovered, 69.3% grew on both IMA and SDA; 24.9% grew only on IMA; and 5.8% grew only on SDA, showing that IMA is superior (P=0.003).

  11. Enumeration of fungi in fruits by the most probable number method.

    PubMed

    Watanabe, Maiko; Tsutsumi, Fumiyuki; Lee, Ken-ichi; Sugita-Konishi, Yoshiko; Kumagai, Susumu; Takatori, Kosuke; Hara-Kudo, Yukiko; Konuma, Hirotaka

    2010-01-01

    In this study, enumeration methods for fungi in foods were evaluated using fruits that are often contaminated by fungi in the field and rot because of fungal contaminants. As the test methods, we used the standard most probable number (MPN) method with liquid medium in test tubes, which is traditionally used as the enumeration method for bacteria, and the plate-MPN method with agar plate media, in addition to the surface plating method as the traditional enumeration method for fungi. We tested 27 samples of 9 commercial domestic fruits using their surface skin. The results indicated that the standard MPN method showed slow recovery of fungi in test tubes and lower counts than the surface plating method and the plate-MPN method in almost all samples. The fungal count on the 4th d of incubation was approximately the same as on the 10th d by the surface plating method or the plate-MPN method, indicating no significant differences between the fungal counts by these 2 methods. This result indicated that the plate-MPN method had a number agreement with the traditional enumeration method. Moreover, the plate-MPN method has a little laborious without counting colonies, because fungal counts are estimated based on the number of plates with growing colonies. These advantages demonstrated that the plate-MPN method is a comparatively superior and rapid method for enumeration of fungi.

  12. High-throughput method for a kinetics analysis of the high-pressure inactivation of microorganisms using microplates.

    PubMed

    Hasegawa, Toshimi; Hayashi, Manabu; Nomura, Kazuki; Hayashi, Mayumi; Kido, Miyuki; Ohmori, Tsuneo; Fukuda, Masao; Iguchi, Akinori; Ueno, Shigeaki; Shigematsu, Toru; Hirayama, Masao; Fujii, Tomoyuki

    2012-06-01

    Using microplates as pressure and cultivation vessels, a high-throughput method was developed for analyzing the high-pressure inactivation kinetics of microorganisms. The loss of viability from a high-pressure treatment, measured based on the growth delay during microplate cultivation, showed reproducibility with the conventional agar plate method and was applicable for the kinetics analysis.

  13. An ultrasonic method for determination of elastic moduli, density, attenuation and thickness of a polymer coating on a stiff plate.

    PubMed

    Lavrentyev, A I; Rokhlin, S I

    2001-04-01

    An ultrasonic method proposed by us for determination of the complete set of acoustical and geometrical properties of a thin isotropic layer between semispaces (J. Acoust. Soc. Am. 102 (1997) 3467) is extended to determination of the properties of a coating on a thin plate. The method allows simultaneous determination of the coating thickness, density, elastic moduli and attenuation (longitudinal and shear) from normal and oblique incidence reflection (transmission) frequency spectra. Reflection (transmission) from the coated plate is represented as a function of six nondimensional parameters of the coating which are determined from two experimentally measured spectra: one at normal and one at oblique incidence. The introduction of the set of nondimensional parameters allows one to transform the reconstruction process from one search in a six-dimensional space to two searches in three-dimensional spaces (one search for normal incidence and one for oblique). Thickness, density, and longitudinal and shear elastic moduli of the coating are calculated from the nondimensional parameters determined. The sensitivity of the method to individual properties and its stability against experimental noise are studied and the inversion algorithm is accordingly optimized. An example of the method and experimental measurement for comparison is given for a polypropylene coating on a steel foil.

  14. Fracture Toughness of Thin Plates by the Double-Torsion Test Method

    NASA Technical Reports Server (NTRS)

    Salem, Jonathan A.; Radovic, Miladin; Lara-Curzio, Edgar; Nelson, George

    2006-01-01

    Double torsion testing can produce fracture toughness values without crack length measurement that are comparable to those measured via standardized techniques such as the chevron-notch, surface-crack-in-flexure and precracked beam if the appropriate geometry is employed, and the material does not exhibit increasing crack growth resistance. Results to date indicate that 8 < W/d < 80 and L/W > 2 are required if crack length is not considered in stress intensity calculations. At L/W = 2, the normalized crack length should be 0.35 < a/L < 0.65; whereas for L/W = 3, 0.2 < a/L < 0.75 is acceptable. In addition, the load-points need to roll to reduce friction. For an alumina exhibiting increasing crack growth resistance, values corresponding to the plateau of the R-curve were measured. For very thin plates (W/d > 80) nonlinear effects were encountered.

  15. Direct Protocol for Ambient Mass Spectrometry Imaging on Agar Culture.

    PubMed

    Angolini, Célio Fernando F; Vendramini, Pedro Henrique; Araújo, Francisca D S; Araújo, Welington L; Augusti, Rodinei; Eberlin, Marcos N; de Oliveira, Luciana Gonzaga

    2015-07-01

    Herein we describe a new protocol that allows direct mass spectrometry imaging (IMS) of agar cultures. A simple sample dehydration leads to a thin solid agar, which enables the direct use of spray-based ambient mass spectrometry techniques. To demonstrate its applicability, metal scavengers siderophores were imaged directly from agar culture of S. wadayamensis, and well resolved and intense images were obtained using both desorption electrospray ionization (DESI) and easy ambient sonic-spray ionization (EASI) with well-defined selective spatial distributions for the free and the metal-bound molecules, providing clues for their roles in cellular metabolism.

  16. Use of Adomian decomposition method in the study of parallel plate flow of a third grade fluid

    NASA Astrophysics Data System (ADS)

    Siddiqui, A. M.; Hameed, M.; Siddiqui, B. M.; Ghori, Q. K.

    2010-09-01

    In this paper, Adomian's decomposition method is used to solve non-linear differential equations which arise in fluid dynamics. We study basic flow problems of a third grade non-Newtonian fluid between two parallel plates separated by a finite distance. The technique of Adomian decomposition is successfully applied to study the problem of a non-Newtonian plane Couette flow, fully developed plane Poiseuille flow and plane Couette-Poiseuille flow. The results obtained show the reliability and efficiency of this analytical method. Numerical solutions are also obtained by solving non-linear ordinary differential equations using Chebyshev spectral method. We present a comparative study between the analytical solutions and numerical solutions. The analytical results are found to be in good agreement with numerical solutions which reveals the effectiveness and convenience of the Adomian decomposition method.

  17. A soft agar colony assay for Lewis lung tumour and B16 melanoma taken directly from the mouse.

    PubMed Central

    Courtenay, V. D.

    1976-01-01

    A soft agar colony assay has been developed for the B16 mouse melanoma and the Lewis lung tumour. The special features of the technique are the use of a gas phase with 5% O2 instead of air and the addition of rat red blood cells. Single cell suspensions are prepared by trypsinization from the solid tumour and the cells are plated out in 0-3% agar over a layer of 0-5% agar in 30-mm Petri dishes. After 8 to 15 days' incubation in 5% O2, colonies of more than 50 cells are produced. Plating efficiencies of between 30 and 50% are usually obtained. The addition of up to 10(4) heavily irradiated tumour cells gives some further improvement in plating efficiency for the B16 melanoma but not for the Lewis lung tumour. Applications of the technique to measure cell survival in the two tumours after treatment with cytotoxic drugs and radiation are reported. The scatter of experimental points is relatively small, and in comparative experiments good agreement has been obtained with results using in vivo assay techniques. PMID:782495

  18. Component mode synthesis and large deflection vibration of complex structures. Volume 2: Single-mode large deflection vibrations of beams and plates using finite element method

    NASA Technical Reports Server (NTRS)

    Mei, Chuh

    1987-01-01

    A finite element method is presented for the large amplitude vibrations of complex structures that can be modelled with beam and rectangular plate elements subjected to harmonic excitation. Both inplane deformation and inertia are considered in the formulation. Derivation of the harmonic force and nonlinear stiffness matrices for a beam and a rectangular plate element are presented. Solution procedures and convergence characteristics of the finite element method are described. Nonlinear response to uniform and concentrated harmonic loadings and improved nonlinear free vibration results are presented for beams and rectangular plates of various boundary conditions.

  19. Evaluation of a new most-probable-number (MPN) dilution plate method for the enumeration of Escherichia coli in water samples.

    PubMed

    Kodaka, Hidemasa; Saito, Mikako; Matsuoka, Hideaki

    2009-09-01

    The purpose of this study was to evaluate the most-probable-number dilution plate (MPN plate) method developed for the enumeration of Escherichia coil in water samples. Sterilized water was inoculated with E. coli ATCC 11775 to give between 2-1600 MPN/100 ml. The MPN was determined for both the MPN plate and 5-tube methods from the MPN table. The average of the natural logarithm (In) MPN with standard deviations in 95 samples was 4.26 +/- 1.48 by the 5-tube-method and 4.18 +/- 1.45 by the MPN plate method. The correlation coefficient was 0.96. These results were not significantly different according to the paired t-test (p > 0.05).

  20. Comparison of dry medium culture plates for mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet products.

    PubMed

    Park, Junghyun; Kim, Myunghee

    2013-12-01

    This study was performed to compare the performance of Sanita-Kun dry medium culture plate with those of traditional culture medium and Petrifilm dry medium culture plate for the enumeration of the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet. Mesophilic aerobic bacteria were comparatively evaluated in milk, ice cream, ham, and codfish fillet using Sanita-Kun aerobic count (SAC), Petrifilm aerobic count (PAC), and traditional plate count agar (PCA) media. According to the results, all methods showed high correlations of 0.989~1.000 and no significant differences were observed for enumerating the mesophilic aerobic bacteria in the tested food products. SAC method was easier to perform and count colonies efficiently as compared to the PCA and PAC methods. Therefore, we concluded that the SAC method offers an acceptable alternative to the PCA and PAC methods for counting the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet products. PMID:24551829

  1. Comparison of dry medium culture plates for mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet products.

    PubMed

    Park, Junghyun; Kim, Myunghee

    2013-12-01

    This study was performed to compare the performance of Sanita-Kun dry medium culture plate with those of traditional culture medium and Petrifilm dry medium culture plate for the enumeration of the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet. Mesophilic aerobic bacteria were comparatively evaluated in milk, ice cream, ham, and codfish fillet using Sanita-Kun aerobic count (SAC), Petrifilm aerobic count (PAC), and traditional plate count agar (PCA) media. According to the results, all methods showed high correlations of 0.989~1.000 and no significant differences were observed for enumerating the mesophilic aerobic bacteria in the tested food products. SAC method was easier to perform and count colonies efficiently as compared to the PCA and PAC methods. Therefore, we concluded that the SAC method offers an acceptable alternative to the PCA and PAC methods for counting the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet products.

  2. Plate motion

    SciTech Connect

    Gordon, R.G. )

    1991-01-01

    The motion of tectonic plates on the earth is characterized in a critical review of U.S. research from the period 1987-1990. Topics addressed include the NUVEL-1 global model of current plate motions, diffuse plate boundaries and the oceanic lithosphere, the relation between plate motions and distributed deformations, accelerations and the steadiness of plate motions, the distribution of current Pacific-North America motion across western North America and its margin, plate reconstructions and their uncertainties, hotspots, and plate dynamics. A comprehensive bibliography is provided. 126 refs.

  3. Multipotent Mesenchymal Stromal Stem Cell Expansion by Plating Whole Bone Marrow at a Low Cellular Density: A More Advantageous Method for Clinical Use

    PubMed Central

    Mareschi, Katia; Rustichelli, Deborah; Calabrese, Roberto; Gunetti, Monica; Sanavio, Fiorella; Castiglia, Sara; Risso, Alessandra; Ferrero, Ivana; Tarella, Corrado; Fagioli, Franca

    2012-01-01

    Mesenchymal stem cells (MSCs) are a promising source for cell therapy due to their pluripotency and immunomodulant proprieties. As the identification of “optimal” conditions is important to identify a standard procedure for clinical use. Percoll, Ficoll and whole bone marrow directly plated were tested from the same sample as separation methods. The cells were seeded at the following densities: 100 000, 10 000, 1000, 100, 10 cells/cm2. After reaching confluence, the cells were detached, pooled and re-plated at 1000, 500, 100, and 10 cells/cm2. Statistical analyses were performed. Cumulative Population Doublings (PD) did not show significant differences for the separation methods and seeding densities but only for the plating density. Some small quantity samples plated in T25 flasks at plating densities of 10 and 100 cells/cm2 did not produce any expansion. However, directly plated whole bone marrow resulted in a more advantageous method in terms of CFU-F number, cellular growth and minimal manipulation. No differences were observed in terms of gross morphology, differentiation potential or immunophenotype. These data suggest that plating whole bone marrow at a low cellular density may represent a good procedure for MSC expansion for clinical use. PMID:23715383

  4. Multipotent mesenchymal stromal stem cell expansion by plating whole bone marrow at a low cellular density: a more advantageous method for clinical use.

    PubMed

    Mareschi, Katia; Rustichelli, Deborah; Calabrese, Roberto; Gunetti, Monica; Sanavio, Fiorella; Castiglia, Sara; Risso, Alessandra; Ferrero, Ivana; Tarella, Corrado; Fagioli, Franca

    2012-01-01

    Mesenchymal stem cells (MSCs) are a promising source for cell therapy due to their pluripotency and immunomodulant proprieties. As the identification of "optimal" conditions is important to identify a standard procedure for clinical use. Percoll, Ficoll and whole bone marrow directly plated were tested from the same sample as separation methods. The cells were seeded at the following densities: 100 000, 10 000, 1000, 100, 10 cells/cm(2). After reaching confluence, the cells were detached, pooled and re-plated at 1000, 500, 100, and 10 cells/cm(2). Statistical analyses were performed. Cumulative Population Doublings (PD) did not show significant differences for the separation methods and seeding densities but only for the plating density. Some small quantity samples plated in T25 flasks at plating densities of 10 and 100 cells/cm(2) did not produce any expansion. However, directly plated whole bone marrow resulted in a more advantageous method in terms of CFU-F number, cellular growth and minimal manipulation. No differences were observed in terms of gross morphology, differentiation potential or immunophenotype. These data suggest that plating whole bone marrow at a low cellular density may represent a good procedure for MSC expansion for clinical use.

  5. Preparation of an agar-silver nanoparticles (A-AgNp) film for increasing the shelf-life of fruits.

    PubMed

    Gudadhe, Janhavi A; Yadav, Alka; Gade, Aniket; Marcato, Priscyla D; Durán, Nelson; Rai, Mahendra

    2014-12-01

    Preparation of protective coating possessing antimicrobial properties is present day need as they increase the shelf life of fruits and vegetables. In the present study, preparation of agar-silver nanoparticle film for increasing the shelf life of fruits is reported. Silver nanoparticles (Ag-NPs) biosynthesised using an extract of Ocimum sanctum leaves, were mixed with agar-agar to prepare an agar-silver nanoparticles (A-AgNp) film. This film was surface-coated over the fruits, Citrus aurantifolium (Thornless lime) and Pyrus malus (Apple), and evaluated for the determination of antimicrobial activity of A-AgNp films using disc diffusion method, weight loss and shelf life of fruits. This study demonstrates that these A-AgNp films possess antimicrobial activity and also increase the shelf life of fruits. PMID:25429496

  6. Evaluation of the petrifilm aerobic count plate for enumeration of aerobic marine bacteria from seawater and Caulerpa lentillifera.

    PubMed

    Kudaka, Jun; Horii, Toru; Tamanaha, Koji; Itokazu, Kiyomasa; Nakamura, Masaji; Taira, Katsuya; Nidaira, Minoru; Okano, Sho; Kitahara, Akio

    2010-08-01

    The enumeration and evaluation of the activity of marine bacteria are important in the food industry. However, detection of marine bacteria in seawater or seafood has not been easy. The Petrifilm aerobic count plate (ACP) is a ready-to-use alternative to the traditional enumeration media used for bacteria associated with food. The purpose of this study was to evaluate the usefulness of a simple detection and enumeration method utilizing the Petrifilm ACP for enumeration of aerobic marine bacteria from seawater and an edible seaweed, Caulerpa lentillifera. The efficiency of enumeration of total aerobic marine bacteria on Petrifilm ACP was compared with that using the spread plate method on marine agar with 80 seawater and 64 C. lentillifera samples. With sterile seawater as the diluent, a close correlation was observed between the method utilizing Petrifilm ACP and that utilizing the conventional marine agar (r=0.98 for seawater and 0.91 for C. lentillifera). The Petrifilm ACP method was simpler and less time-consuming than the conventional method. These results indicate that Petrifilm ACP is a suitable alternative to conventional marine agar for enumeration of marine microorganisms in seawater and C. lentillifera samples.

  7. Development of simple high-precision two-dimensional dose-distribution measurement method for proton beam therapy using imaging plate and EBT3.

    PubMed

    Mori, Yutaro; Isobe, Tomonori; Yamaguchi, Yoshiki; Takei, Hideyuki; Kamizawa, Satoshi; Terunuma, Toshiyuki; Sato, Eisuke; Takada, Kenta; Tadano, Kiichi; Yoshimura, Yousuke; Sakurai, Hideyuki; Sakae, Takeji

    2016-09-01

    Although there are several two-dimensional (2D) dose-distribution measurement methods using proton beam therapy, they all have drawbacks; hence, there is no standard method established worldwide. The purpose of this study was to develop a simple, high-precision 2D distribution measurement method for proton beam therapy that uses an imaging plate and EBT3. First, we expanded the maximum readable dose (saturation dose) in the imaging plate. The method involves (i) the control of the fading phenomenon by an annealing process and (ii) the control of the photostimulated luminescence (PSL) phenomenon using a longpass filter (LPF). In method (i), upon heating at 80 °C, the PSL became 0.485 times the room temperature, and in method (ii), we attenuated the PSL by a factor of 0.245 using an LPF. Thus, by combining methods (i) and (ii), we expanded the saturation dose to 2 Gy. Thus, it was possible to measure the imaging plate and EBT3 in the same dose range. We simultaneously measured the percent depth dose using imaging plate and EBT3. We defined a correction factor to match the measured values-which had a reduced sensitivity because of the linear energy transfer (LET) dependence of the imaging plate and EBT3-with reference data and developed a correction factor function. Subsequently, by defining the relative LET dependence of imaging plate and EBT3 as the relative sensitivity and converting the relationship imaging plate between the relative sensitivity and correction factor into a function, we obtained a sensitivity-correction function. By employing this function, measurements with the same accuracy as the reference data were performed using the imaging plate and EBT3. PMID:27470695

  8. [Evaluation of blood agar medium for the growth of mycobacteria].

    PubMed

    Coban, Ahmet Yılmaz; Akgüneş, Alper; Durupınar, Belma

    2011-10-01

    This study was aimed to evaluate the performance of blood agar for the growth of mycobacteria from clinical specimens sent to Mycobacteriology Laboratory of Samsun Chest Diseases Hospital. One hundred fifty six clinical specimens including 123 sputum, 28 bronchoalveolar lavage (BAL) and 5 pleural fluid specimens were inoculated in Löwenstein-Jensen (LJ), BACTEC MGIT 960 system (Becton Dickinson, USA) and blood agar following decontamination process. The specimens were also simultaneously examined for the presence of acid-fast bacilli (AFB). Thirty five mycobacteria strains (33 Mycobacterium tuberculosis and 2 atypical mycobacteria) grew in blood agar, 38 (36 M.tuberculosis and 2 atypical mycobacteria) in LJ media and 46 (44 M.tuberculosis and 2 atypical mycobacteria) in BACTEC MGIT 960 system. Among 29 AFB negative specimens, 20 revealed growth in both blood agar and LJ medium and 27 in MGIT system. AFB positive 20 samples yielded growth in 15 samples in blood agar, 18 in LJ medium and 19 in MGIT system. Among the total of 156 samples, contamination was observed in 15 (9.6%) samples in blood agar, 16 (10.2%) in LJ medium and 18 (11.5%) in MGIT system. Growth time was 5-35 days (mean 18 ± 7.4), 11-35 days (mean 19 ± 5.9) and 5-15 days (mean 10 ± 2.4) for blood agar, LJ medium and BACTEC MGIT 960 system, respectively. The three samples which revealed contamination in BACTEC MGIT 960 system, grew successfully in both blood agar and LJ medium without contamination. In one sample, growth was observed only in LJ medium but neither in blood agar nor BACTEC MGIT 960 system. However, in another sample, growth was observed only in blood agar while no growth was detected in LJ or BACTEC MGIT 960 system. Six samples yielded mycobacteria only in BACTEC MGIT 960 system. These results indicated that simultaneous use of one liquid and one solid medium to grow mycobacteria from the clinical samples seemed to be complementary. Blood agar was a promising choice since it was found

  9. A method to increase the nominal range resolution of a stack of parallel-plate ionization chambers

    NASA Astrophysics Data System (ADS)

    Rinaldi, I.; Brons, S.; Jäkel, O.; Voss, B.; Parodi, K.

    2014-09-01

    A detector prototype based on a stack of 61 parallel-plate ionisation chambers (PPIC) interleaved with absorber plates of polymethyl methacrylate (PMMA) was assembled for transmission imaging purposes in ion beam therapy. The thickness of the absorber sheets in the PPIC stack determines the nominal range resolution of the detector. In the current set-up, 3 mm PMMA slabs are used. The signal of the 61 active channels of the stack thereby provides a discrete approximation of the Bragg curve in the detector. In this work, a data processing method to increase the range resolution (MIRR) in a stack of ionization chambers is presented. In the MIRR the position of the maximum of the Bragg curve is deduced from the ratio of measured signals in adjacent PPIC channels. The method is developed based on Bragg curves obtained from Monte Carlo simulations and validated with experimental data of a wedge-shaped PMMA phantom acquired with the PPIC stack using carbon ion beams. The influence of the initial beam energy and of phantom inhomogeneities on the MIRR is quantitatively evaluated. Systematic errors as well as inaccuracies related to signal noise are discussed and quantified. It is shown that with the MIRR an increased range resolution of 0.7 mm PMMA equivalent or 0.8 mm water equivalent thickness is achieved for the considered experimental data.

  10. Dynamics of Prestressed Rotating Anisotropic Plates Subject to Transverse Loads and Heat Sources, Part i: Modelling and Solution Method

    NASA Astrophysics Data System (ADS)

    SON, HEUIGI; KIKUCHI, NOBORU; GALIP ULSOY, A.; YIGIT, AHMET S.

    2000-09-01

    This paper considers the application of the finite element method for the analysis of translating or rotating plates, based on Mindlin plate theory and the von Kármán strain expression, in the context of linear thermoelasticity. The existence of convective terms generates gyroscopic terms, unstabilizing effects in the stiffness matrix, and radial in-plane tension. Homogenization theory, applicable to not only determining the global material properties for composite materials like laminate or fiber-reinforced matrix, but also computing microscopic stress levels, was applied to obtain orthotropic material properties. The quasi-static stretching assumption was used to simplify the governing equations. A second order implicit time-integration scheme, applicable for both the linear and non-linear governing equations, was presented, which allows a time increment sufficiently large (without numerical stability problems) based on the accuracy needed. This paper (Part I) presents the problem formulation and solution methods, while a companion paper (Part II) presents and discusses results for specially orthotropic rotating disks.

  11. Simple method for the analysis of food dyes on reversed-phase thin-layer plates.

    PubMed

    Oka, H; Ikai, Y; Kawamura, N; Yamada, M; Inoue, H; Ohno, T; Inagaki, K; Kuno, A; Yamamoto, N

    1987-12-18

    A technique for the determination of food dyes using reversed-phase thin-layer chromatography on octadecyl-modified silica is described. A solvent system containing 5.0% aqueous sodium sulphate solution enables good separation of the food dyes. Their separation is dependent on the pH of the solvent system, good separation among all dyes being obtained between pH 6.0 and 7.0. The determination of thirteen dyes can be achieved by a combination of methanol-acetonitrile-5.0% aqueous sodium sulphate solution (3:3:10) (solvent system A) and methanol-methyl ethyl ketone-5.0% aqueous sodium sulphate solution (1:1:1) (solvent system B). Solvent system A was used for the determination of Tartrazine, Amaranth, Indigo Carmine, New Coccine, Sunset Yellow FCF, Allura Red AC, Fast Green FCF and Brilliant Blue FCF and for the screening of Acid Red (R-106), Eosin (R-103), Erythrosin (R-3), Rose Bengale (R-105) and Phloxine (R-104). When the spots of R-3, R-103, R-104, R-105 and R-106 appear on the plate, their determination can be achieved by using solvent system B. Each calibration graph was linear between 0.2 and 1.0 micrograms.

  12. Detection by hyperspectral imaging of shiga toxin-producing Escherichia coli serogroups O26, O45, O103, O111, O121, and O145 on rainbow agar.

    PubMed

    Windham, William R; Yoon, Seung-Chul; Ladely, Scott R; Haley, Jennifer A; Heitschmidt, Jerry W; Lawrence, Kurt C; Park, Bosoon; Narrang, Neelam; Cray, William C

    2013-07-01

    The U.S. Department of Agriculture, Food Safety Inspection Service has determined that six non-O157 Shiga toxin-producing Escherichia coli (STEC) serogroups (O26, O45, O103, O111, O121, and O145) are adulterants in raw beef. Isolate and phenotypic discrimination of non-O157 STEC is problematic due to the lack of suitable agar media. The lack of distinct phenotypic color variation among non-O157serogroups cultured on chromogenic agar poses a challenge in selecting colonies for confirmation. In this study, visible and near-infrared hyperspectral imaging and chemometrics were used to detect and classify non-O157 STEC serogroups grown on Rainbow agar O157. The method was first developed by building spectral libraries for each serogroup obtained from ground-truth regions of interest representing the true identity of each pixel and thus each pure culture colony in the hyperspectral agar-plate image. The spectral library for the pure-culture non-O157 STEC consisted of 2,171 colonies, with spectra derived from 124,347 of pixels. The classification models for each serogroup were developed with a k nearest-neighbor classifier. The overall classification training accuracy at the colony level was 99%. The classifier was validated with ground beef enrichments artificially inoculated with 10, 50, and 100 CFU/ml STEC. The validation ground-truth regions of interest of the STEC target colonies consisted of 606 colonies, with 3,030 pixels of spectra. The overall classification accuracy was 98%. The average specificity of the method was 98% due to the low false-positive rate of 1.2%. The sensitivity ranged from 78 to 100% due to the false-negative rates of 22, 7, and 8% for O145, O45, and O26, respectively. This study showed the potential of visible and near-infrared hyperspectral imaging for detecting and classifying colonies of the six non-O157 STEC serogroups. The technique needs to be validated with bacterial cultures directly extracted from meat products and positive

  13. Evaluation of potassium-clavulanate-supplemented modified charcoal-cefoperazone-deoxycholate agar for enumeration of Campylobacter in chicken carcass rinse.

    PubMed

    Chon, Jung-Whan; Kim, Hong-Seok; Kim, Hyunsook; Oh, Deog-Hwan; Seo, Kun-Ho

    2014-05-01

    Potassium-clavulanate-supplemented modified charcoal-cefoperazone-deoxycholate agar (C-mCCDA) that was described in our previous study was compared with original mCCDA for the enumeration of Campylobacter in pure culture and chicken carcass rinse. The quantitative detection of viable Campylobacter cells from a pure culture, plated on C-mCCDA, is statistically similar (P > 0.05) to mCCDA. In total, 120 chickens were rinsed using 400 mL buffered peptone water. The rinses were inoculated onto C-mCCDA and mCCDA followed by incubation at 42 °C for 48 h. There was no statistical difference between C-mCCDA (45 of 120 plates; mean count, 145.5 CFU/mL) and normal mCCDA (46 of 120 plates; mean count, 160.8 CFU/mL) in the isolation rate and recovery of Campylobacter (P > 0.05) from chicken carcass rinse. The Pearson correlation coefficient value for the number of Campylobacter cells recovered in the 2 media was 0.942. However, the selectivity was much better on C-mCCDA than on mCCDA plates (P < 0.05). Significantly fewer C-mCCDA plates (33 out of 120 plates; mean count, 1.9 CFU/mL) were contaminated with non-Campylobacter cells than the normal mCCDA plates (67 out of 120 plates; mean count, 27.1 CFU/mL). The C-mCCDA may provide improved results for enumeration of Campylobacter in chicken meat alternative to mCCDA with its increased selectivity the modified agar possess.

  14. [PHYSICAL AND MATHEMATICAL GROUNDS LANDFORMS BASIS PLATE DENTURES WHEN APPLYING THE COMPLEX METHOD OF PREVENTION OF PROSTHETIC STOMATITIS].

    PubMed

    Zverkhanovsky, A

    2016-06-01

    Objective - to develop the form of the drug reservoir to hold the vegetable oils under the basis of the prosthesis. The research was conducted on the Bench PMMA samples. The comparison group consisted of smooth plate PMMA. Two study groups were PMMA plates with grooves on one side of a square with sides of 2 mm and depth of channel - 1 mm. The third group consisted of the experimental plate with diamond-shaped notches with the same parameters. The lowest value of the stress in the plate having a rhombic grid, they are 54% less than in the smooth plate and 37% less than in the plate with a square lattice (the best strength characteristics in a rhombic plate with grille). Equivalent move from the plate with a rhombic lattice is less than an order of magnitude than that of a smooth plate and by 5.8% more than at the plate with a square lattice, which indicates good performance design plasticity with rhombic grid. Basis with the rhombic lattice on the surface has the best record on the stress-strain state in comparison with other models considered (smooth plate with a square lattice plate). PMID:27441532

  15. [PHYSICAL AND MATHEMATICAL GROUNDS LANDFORMS BASIS PLATE DENTURES WHEN APPLYING THE COMPLEX METHOD OF PREVENTION OF PROSTHETIC STOMATITIS].

    PubMed

    Zverkhanovsky, A

    2016-06-01

    Objective - to develop the form of the drug reservoir to hold the vegetable oils under the basis of the prosthesis. The research was conducted on the Bench PMMA samples. The comparison group consisted of smooth plate PMMA. Two study groups were PMMA plates with grooves on one side of a square with sides of 2 mm and depth of channel - 1 mm. The third group consisted of the experimental plate with diamond-shaped notches with the same parameters. The lowest value of the stress in the plate having a rhombic grid, they are 54% less than in the smooth plate and 37% less than in the plate with a square lattice (the best strength characteristics in a rhombic plate with grille). Equivalent move from the plate with a rhombic lattice is less than an order of magnitude than that of a smooth plate and by 5.8% more than at the plate with a square lattice, which indicates good performance design plasticity with rhombic grid. Basis with the rhombic lattice on the surface has the best record on the stress-strain state in comparison with other models considered (smooth plate with a square lattice plate).

  16. Comparison of methods of immobilization to enzyme-linked immunosorbent assay plates for the detection of sugar chains.

    PubMed

    Satoh, A; Fukui, E; Yoshino, S; Shinoda, M; Kojima, K; Matsumoto, I

    1999-11-15

    The immobilization of carbohydrates for solid-phase assays, including enzyme-linked immunosorbent assay (ELISA), is difficult because they are hydrophilic. We developed four new methods for the immobilization of oligosaccharides. ELISA plates were first coated with methyl vinyl ether-maleic anhydride copolymer (MMAC) and an excess of active anhydride groups was introduced. They were subsequently reacted, in four different ways, to bind oligosaccharides. In method 1, the anhydride groups were reacted with hydrazide groups, in the presence of adipic acid dihydrazide, and then coupled to the reducing ends of sugar chains by reductive amination. In method 2, the anhydride groups were reacted with p-aminophenyl glycoside obtained by reduction with p-nitrophenyl glycoside. In method 3, the anhydride groups were reacted with 1, 6-hexamethylenediamine. Aminooxy groups were coupled to the amino groups introduced and then aminooxyacetic acid with carbodiimide and ligated to oligosaccharides by oxime formation. In method 4, stereospecifically aminated oligosaccharides reacted with the anhydride groups. We compared, in solid-phase assays systems, the ability of lectins to detect oligosaccharides immobilized with either one of these four new methods or one of the two methods previously described. Detection of sugars with lectins is useful because, in most cases, they recognize sugars stereospecifically. The immobilization method should therefore be carefully selected to avoid changing the configuration and substitution in C-1. PMID:10552909

  17. Use of Mueller-Hinton broth and agar in the germ tube test.

    PubMed

    Mattei, Antonella Souza; Alves, Sydney Hartz; Severo, Cecília Bittencourt; Guazzelli, Luciana da Silva; Oliveira, Flávio de Mattos; Severo, Luiz Carlos

    2014-01-01

    Candida albicans is often isolated from clinical samples, thus its presumptive differentiation from other species of the same genus can be based on its ability to form the germ tube in human serum. Nevertheless, there are two other species that share this characteristic: C. dubliniensis and C. africana. The aim of this study was to compare four different substrates to perform the germ tube (GT) test. The Candida spp. isolates were identified using a manual system (135 C. albicans, 24 C. tropicalis and one C. dubliniensis). The germ tube test was performed with fresh, previously frozen serum and Mueller-Hinton (MH) broth and agar. GT was observed in 96% (130/136) of the isolates through the fresh serum technique, 94% (128/136) through previously frozen serum, 92% (125/136) in MH agar, and 90% (122/136) in MH broth. The sensitivity of each test was higher than 90%, with 100% specificity. Both the MH agar and broth were able to identify the true positives, and false positives were not found. However, some C. albicans isolates were not identified. MH agar and broth may be used in laboratory for the rapid presumptive identification of C. albicans, as an alternative method for germ tube test.

  18. Factors influencing the accuracy of the plating method used to enumerate low numbers of viable micro-organisms in food.

    PubMed

    Jongenburger, I; Reij, M W; Boer, E P J; Gorris, L G M; Zwietering, M H

    2010-09-30

    This study aims to assess several factors that influence the accuracy of the plate count technique to estimate low numbers of micro-organisms in liquid and solid food. Concentrations around 10CFU/mL or 100CFU/g in the original sample, which can still be enumerated with the plate count technique, are considered as low numbers. The impact of low plate counts, technical errors, heterogeneity of contamination and singular versus duplicate plating were studied. Batches of liquid and powdered milk were artificially contaminated with various amounts of Cronobacter sakazakii strain ATCC 29544 to create batches with accurately known levels of contamination. After thoroughly mixing, these batches were extensively sampled and plated in duplicate. The coefficient of variation (CV) was calculated for samples from both batches of liquid and powdered product as a measure of the dispersion within the samples. The impact of technical errors and low plate counts were determined theoretically, experimentally, as well as with Monte Carlo simulations. CV-values for samples of liquid milk batches were found to be similar to their theoretical CV-values established by assuming Poisson distribution of the plate counts. However, CV-values of samples of powdered milk batches were approximately five times higher than their theoretical CV-values. In particular, powdered milk samples with low numbers of Cronobacter spp. showed much more dispersion than expected which was likely due to heterogeneity. The impact of technical errors was found to be less prominent than that of low plate counts or of heterogeneity. Considering the impact of low plate counts on accuracy, it would be advisable to keep to a lower limit for plate counts of 25 colonies/plate rather than to the currently advocated 10 colonies/plate. For a powdered product with a heterogeneous contamination, it is more accurate to use 10 plates for 10 individual samples than to use the same 10 plates for 5 samples plated in duplicate.

  19. Plate-like SrFe12O19 particles prepared by modified sol-gel method

    NASA Astrophysics Data System (ADS)

    Sapoletova, Nina A.; Kushnir, Sergey E.; Li, Yong Hui; An, Sung Yong; Seo, Jung-wook; Hur, Kang Heon

    2015-09-01

    M-type strontium hexaferrite powders were synthesized by the modified sol-gel method with calcination in NaCl matrix in a temperature range 790-850 °C for 1 h. X-ray diffraction analysis shows the formation of pure M-type strontium hexaferrite phase. The SrFe12O19 particles have a plate-like shape with a mean diameter 130-185 nm and a thickness 45-55 nm. The prepared powders show a saturation magnetization 70-72 emu/g and a coercive force 6.0-6.4 kOe. The suggested synthesis method combines simplicity, using of low calcination temperatures and allows to synthesize pure strontium hexaferrite powders with excellent hard magnetic properties.

  20. [Comparison of intestinal bacteria composition identified by various analytical methods].

    PubMed

    Fujisawa, Tomohiko

    2014-01-01

    Many different kinds of bacteria are normally found in the intestines of healthy humans and animals. To study the ecology and function of these intestinal bacteria, the culture method was fundamental until recent years, and suitable agar plates such as non-selective agar plates and several selective agar plates have been developed. Furthermore, the roll-tube, glove box, and plate-in-bottle methods have also been developed for the cultivation of fastidious anaerobes that predominantly colonize the intestine. Until recently, the evaluation of functional foods such as pre- and probiotics was mainly done using culture methods, and many valuable data were produced. On the other hand, genomic analysis such as the fluorescence in situ hybridization (FISH), quantitative PCR (qPCR), clone-library, denaturing gradient gel electrophoresis (DGGE), temperature gradient gel electrophoresis (TGGE), terminal-restriction fragment length polymorphism (T-RFLP) methods, and metagenome analysis have been used for the investigation of intestinal microbiota in recent years. The identification of bacteria is done by investigation of the phenotypic characteristics in culture methods, while rRNA genes are used as targets in genomic analysis. Here, I compare the fecal bacteria identified by various analytical methods.

  1. Air-coupled method to investigate the lowest-order antisymmetric Lamb mode in stubbed and air-drilled phononic plates

    NASA Astrophysics Data System (ADS)

    Zhang, Dongbo; Zhao, Jinfeng; Bonello, Bernard; Li, Libing; Wei, Jianxin; Pan, Yongdong; Zhong, Zheng

    2016-08-01

    In this work, we applied a robust and fully air-coupled method to investigate the propagation of the lowest-order antisymmetric Lamb (A0) mode in both a stubbed and an air-drilled phononic-crystal (PC) plate. By measuring simply the radiative acoustic waves of A0 mode close to the plate surface, we observed the band gaps for the stubbed PC plate caused by either the local resonance or the Bragg scattering, in frequency ranges in good agreement with theoretical predictions. We measured then the complete band gap of A0 mode for the air-drilled PC plate, in good agreement with the band structures. Finally, we compared the measurements made using the air-coupled method with those obtained by the laser ultrasonic technique.

  2. Application of laser ranging and VLBI data to a study of plate tectonic driving forces. [finite element method

    NASA Technical Reports Server (NTRS)

    Solomon, S. C.

    1980-01-01

    The measurability of changes in plate driving or resistive forces associated with plate boundary earthquakes by laser rangefinding or VLBI is considered with emphasis on those aspects of plate forces that can be characterized by such measurements. Topics covered include: (1) analytic solutions for two dimensional stress diffusion in a plate following earthquake faulting on a finite fault; (2) two dimensional finite-element solutions for the global state of stress at the Earth's surface for possible plate driving forces; and (3) finite-element solutions for three dimensional stress diffusion in a viscoelastic Earth following earthquake faulting.

  3. Cost-effective nanoporous Agar-Agar polymer/Nickel powder composite particle for effective bio-products adsorption by expanded bed chromatography.

    PubMed

    Asgari, Setareh; Jahanshahi, Mohsen; Rahimpour, Ahmad

    2014-09-26

    In the present work a novel kind of dense nanoporous composite matrix for expanded bed application has been successfully first prepared with Nickel powder as a densifier and was covered with Agar-Agar layer as a skeleton, through the method of water-in-oil emulsification. Agar-Agar is a porous and inexpensive polymer. In order to fabricate cost-effective adsorbent with favorable qualities Agar-Agar polymer was used. Thereafter, the customized composite particle was modified by pseudo-affinity dye-ligand, Reactive Blue 4 (RB4), aimed at preparing a pseudo-affinity adsorbent (RB4-Agar-Ni) for bioprodut adsorption from aqueous solution. Bovine Serum Albumin (BSA) was selected as a model protein to investigate the adsorption behavior in batchwise and expanded bed chromatography, and the obtained results were evaluated with that of Streamline™ (Amersham-Pharmacia Biotech, Sweden). Spherical appearance and porous structure of composite particles were observed by the optical microscope (OM) and scanning electronic microscope (SEM). The results suggested that the matrices followed the logarithmic normal size distribution with the range of 65-300 μm and average diameter of 126.81-151.47 μm, proper wet density of 1.64-2.78 g/ml, water content of 62.74-34%, porosity of 98-90% and pore size of about 38-130 nm. For better comprehension of the impact of solid phase properties on the performance of the expanded bed, the expansion and hydrodynamic properties of a composite matrix with a series of densities was evaluated and estimated by the retention time distribution method (RTD) in an expanded bed and was compared with that of other matrices. According to obtained results the expansion factors under the same fluid velocity decreased by increasing the matrix density. Moreover, the axial dispersion coefficient (Dax) is the most appropriate parameter for evaluating the stability of expanded bed, on various operating conditions, such as different flow velocity, bed expansion

  4. Cost-effective nanoporous Agar-Agar polymer/Nickel powder composite particle for effective bio-products adsorption by expanded bed chromatography.

    PubMed

    Asgari, Setareh; Jahanshahi, Mohsen; Rahimpour, Ahmad

    2014-09-26

    In the present work a novel kind of dense nanoporous composite matrix for expanded bed application has been successfully first prepared with Nickel powder as a densifier and was covered with Agar-Agar layer as a skeleton, through the method of water-in-oil emulsification. Agar-Agar is a porous and inexpensive polymer. In order to fabricate cost-effective adsorbent with favorable qualities Agar-Agar polymer was used. Thereafter, the customized composite particle was modified by pseudo-affinity dye-ligand, Reactive Blue 4 (RB4), aimed at preparing a pseudo-affinity adsorbent (RB4-Agar-Ni) for bioprodut adsorption from aqueous solution. Bovine Serum Albumin (BSA) was selected as a model protein to investigate the adsorption behavior in batchwise and expanded bed chromatography, and the obtained results were evaluated with that of Streamline™ (Amersham-Pharmacia Biotech, Sweden). Spherical appearance and porous structure of composite particles were observed by the optical microscope (OM) and scanning electronic microscope (SEM). The results suggested that the matrices followed the logarithmic normal size distribution with the range of 65-300 μm and average diameter of 126.81-151.47 μm, proper wet density of 1.64-2.78 g/ml, water content of 62.74-34%, porosity of 98-90% and pore size of about 38-130 nm. For better comprehension of the impact of solid phase properties on the performance of the expanded bed, the expansion and hydrodynamic properties of a composite matrix with a series of densities was evaluated and estimated by the retention time distribution method (RTD) in an expanded bed and was compared with that of other matrices. According to obtained results the expansion factors under the same fluid velocity decreased by increasing the matrix density. Moreover, the axial dispersion coefficient (Dax) is the most appropriate parameter for evaluating the stability of expanded bed, on various operating conditions, such as different flow velocity, bed expansion

  5. Comparison of the Roll Plate Method to the Sonication Method To Diagnose Catheter Colonization and Bacteremia in Patients with Long-Term Tunnelled Catheters: a Randomized Prospective Study▿

    PubMed Central

    Slobbe, Lennert; el Barzouhi, Abdelilah; Boersma, Eric; Rijnders, Bart J. A.

    2009-01-01

    Diagnosing catheter-related bloodstream infection (CRBSI) still often involves tip culture. The conventional method is the semiquantitative roll plate method. However, the use of a quantitative sonication technique could have additional value, as it may detect endoluminal microorganisms more easily. Because endoluminal infection tends to occur in long-term central venous catheters, we compared both techniques for patients with long-term tunnelled catheters. For 313 consecutive Hickman catheter tips from 279 hematological patients, colonization detection rates were compared by performing both techniques in a random order, using conventional detection cutoffs. Additionally, for the subgroup of patients with clinical suspicion of CRBSI (n = 89), the diagnostic values of both techniques were compared. The overall tip colonization rate was 25%. For each technique, the detection rate tended to be better if that technique was performed first. The diagnostic performance for the subgroup of patients with clinical suspicion of CRBSI was limited and not different for both methods. Sensitivity and specificity were 45% and 84%, respectively, for sonication versus 35% and 90%, respectively, for the roll plate technique. The fact that 35 of 40 patients with CRBSI received antimicrobial therapy before catheter removal and tip culture, in an attempt to salvage the catheter, may partly explain this poor performance. No differences were observed when catheters were stratified according to in situ time below or above the median of 4 weeks. The sonication culture technique was not better than the roll plate method to diagnose tip colonization or CRBSI in patients with long-term tunnelled catheters. PMID:19171682

  6. Electrode Plate For An Eletrlchemical Cell And Having A Metal Foam Type Support, And A Method Of Obtaining Such An Electrode

    DOEpatents

    Verhoog, Roelof; Precigout, Claude; Stewart, Donald

    1996-05-21

    The electrode plate includes an active portion that is pasted with active material, and a plate head that is made up of three layers of compressed metal foam comprising: a non-pasted portion of height G of the support of the electrode plate; and two strips of non-pasted metal foam of height R on either side of the non-pasted portion of height G of the support and also extending for an overlap height h.sub.2 over the pasted portion of the support. The plate head includes a zone of reduced thickness including a portion that is maximally compressed, and a transitional portion between said maximally compressed portion and the remainder of the electrode which is of thickness e.sub.2. A portion of said plate head forms a connection tab. The method of obtaining the electrode consists in simultaneously rolling all three layers of metal foam in the plate head, and then in cutting matter away from the plates so as to obtain respective connection tabs.

  7. Agar/collagen membrane as skin dressing for wounds.

    PubMed

    Bao, Lei; Yang, Wei; Mao, Xuan; Mou, Shansong; Tang, Shunqing

    2008-12-01

    Agar, a highly hydrophilic polymer, has a special gel property and favorable biocompatibility, but moderate intension strength in an aqueous condition and a low degradation rate. In order to tailor both properties of mechanical intension and degradation, type I collagen was composited with agar in a certain ratio by drying at 50 degrees C or by a freeze-dry process. Glutaraldehyde was chosen as a crosslinking agent, and the most favorable condition for crosslinking was that the weight ratio of agar to glutaraldehyde was 66.7 and the pH value about 5. Dynamic mechanical analysis results showed that the single agar membrane had a modulus value between 640 MPa and 1064 MPa, but it was between 340 MPa and 819 MPa after being composited with type I collagen. It was discovered under an optical microscope that the pores were interconnected in the composite scaffolds instead of the honeycomb-like pores in a single type I collagen scaffold or the laminated gaps in a single agar scaffold. The results of an acute toxicity test disclosed that the composites were not toxic to mice although the composites were crosslinked with a certain concentration of glutaraldehyde. The results of gross examinations showed that when the composite membranes or scaffolds were applied to a repair rabbit skin lesion, the composites had a good repair effect without infection, liquid exudation or visible scar in the lesion covered with them. But in the control group, the autologous skin showed necrosis and there were a lot of scar tissues in the lesion site. H&E staining results showed that the repair tissue was similar to the normal one and very few scaffolds or membranes were left without degradation after 2 or 3 weeks. In conclusion, it is proved that type I collagen increases the toughness of the agar membrane, and the agar/type I collagen composites are promising biomaterials as wound dressings for healing burns or ulcers.

  8. Production of microbial medium from defatted brebra (Milletia ferruginea) seed flour to substitute commercial peptone agar

    PubMed Central

    Andualem, Berhanu; Gessesse, Amare

    2013-01-01

    Objective To investigate and optimize microbial media that substitute peptone agar using brebra seed defatted flour. Methods 'Defatted process, inoculums preparation, evaluation of bacterial growth, preparation of cooked and hydrolyzed media and growth turbidity of tested bacteria were determined. Results Two percent defatted flour was found to be suitable concentration for the growth of pathogenic bacteria: Escherichia coli (ATCC 25922) (E. coli), Pseudomonas aeruginosa (ATCC 27853), Salmonella (NCTC 8385) and Shigella flexneri (ATCC 12022) (S. flexneri), while 3% defatted flour was suitable for Staphylococcus aureus (ATCC 25923) (S. aureus). E. coli (93±1) and S. flexneri (524±1) colony count were significantly (P≤0.05) greater in defatted flour without supplement than in supplemented medium. E. coli [(3.72×109±2) CFU/mL], S. aureus [(7.4×109±2) CFU/mL], S. flexneri [(4.03×109±2) CFU/mL] and Salmonella [(2.37×109±1) CFU/mL] in non-hydrolyzed sample were statistically (P≤0.05) greater than hydrolyzed one and commercial peptone agar. Colony count of Salmonella [(4.55×109±3) CFU/mL], S. flexneri [(5.40×109±3) CFU/mL] and Lyesria moncytogenes (ATCC 19116) [(5.4×109±3) CFU/mL] on raw defatted flour agar was significantly (P≤0.05) greater than cooked defatted flour and commercial peptone agar. Biomass of E. coli, S. aureus, Salmonella and Enterococcus faecalis in non-hydrolyzed defatted flour is highly increased over hydrolyzed defatted flour and commercial peptone broth. Conclusions The defatted flour agar was found to be better microbial media or comparable with peptone agar. The substances in it can serve as sources of carbon, nitrogen, vitamins and minerals that are essential to support the growth of microorganisms without any supplements. Currently, all supplements of peptone agar are very expensive in the market. PMID:24075344

  9. Evaluation of chromogenic agar, [corrected] VITEK2 YST and VITEK® MS for identification of Candida strains isolated from blood cultures.

    PubMed

    Sariguzel, Fatma Mutlu; Berk, Elife; Koc, Ayse Nedret; Sav, Hafize; Aydemir, Gonca

    2015-12-01

    The aim of this study is to compare conventional methods, chromogenic agar, [corrected] VITEK2 YST card and VITEK®MS system for the identification of Candida strains isolated from blood cultures. Fifty-four strains were identified according to conventional methods, chromogenic agar, [corrected] VITEK2 YST card and VITEK®MS. Sequencing was used as the reference method. The 54 strains included 32 Candida parapsilosis, 19 Candida albicans, 1 Candida glabrata and 2 Candida tropicalis according to the reference method. One C. albicans and one C. glabrata isolate were misidentified as C. parapsilosis by chromogenic agar. [corrected]. Two C. parapsilosis and three C. albicans isolates were misidentified by VITEK2 YST card. Chromogenic agar, [corrected] VITEK2 YST card and VITEK®MS identified correctly 96.2%, 90.7% and 100% of all strains, respectively. We found that the chromogenic agar, [corrected] VITEK2 YST card and VITEK®MS system are easy, rapid and accurate alternative methods for the identification of yeast species in the clinical microbiology laboratory.

  10. Simulation of ultrasonic wave propagation in anisotropic poroelastic bone plate using hybrid spectral/finite element method.

    PubMed

    Nguyen, Vu-Hieu; Naili, Salah

    2012-08-01

    This paper deals with the modeling of guided waves propagation in in vivo cortical long bone, which is known to be anisotropic medium with functionally graded porosity. The bone is modeled as an anisotropic poroelastic material by using Biot's theory formulated in high frequency domain. A hybrid spectral/finite element formulation has been developed to find the time-domain solution of ultrasonic waves propagating in a poroelastic plate immersed in two fluid halfspaces. The numerical technique is based on a combined Laplace-Fourier transform, which allows to obtain a reduced dimension problem in the frequency-wavenumber domain. In the spectral domain, as radiation conditions representing infinite fluid halfspaces may be exactly introduced, only the heterogeneous solid layer needs to be analyzed by using finite element method. Several numerical tests are presented showing very good performance of the proposed procedure. A preliminary study on the first arrived signal velocities computed by using equivalent elastic and poroelastic models will be presented.

  11. Thermodynamic equilibrium solubility measurements in simulated fluids by 96-well plate method in early drug discovery.

    PubMed

    Bharate, Sonali S; Vishwakarma, Ram A

    2015-04-01

    An early prediction of solubility in physiological media (PBS, SGF and SIF) is useful to predict qualitatively bioavailability and absorption of lead candidates. Despite of the availability of multiple solubility estimation methods, none of the reported method involves simplified fixed protocol for diverse set of compounds. Therefore, a simple and medium-throughput solubility estimation protocol is highly desirable during lead optimization stage. The present work introduces a rapid method for assessment of thermodynamic equilibrium solubility of compounds in aqueous media using 96-well microplate. The developed protocol is straightforward to set up and takes advantage of the sensitivity of UV spectroscopy. The compound, in stock solution in methanol, is introduced in microgram quantities into microplate wells followed by drying at an ambient temperature. Microplates were shaken upon addition of test media and the supernatant was analyzed by UV method. A plot of absorbance versus concentration of a sample provides saturation point, which is thermodynamic equilibrium solubility of a sample. The established protocol was validated using a large panel of commercially available drugs and with conventional miniaturized shake flask method (r(2)>0.84). Additionally, the statistically significant QSPR models were established using experimental solubility values of 52 compounds.

  12. A rapid method for detecting specific amplified PCR fragments in microtiter plates.

    PubMed Central

    Ortiz, A; Ritter, E

    1996-01-01

    A simple method is presented to circumvent laborious and time consuming electrophoretic separations of specific PCR amplification products. Specific target DNA is amplified using nucleotides labelled with DIG-dUTP or biotin-dCTP. The labelled PCR products are separated from unincorporated nucleotides or oligonucleotides by using a positively charged DEAE cellulose matrix. Amplification products are visualized directly in the matrix using immunoenzymatic methods or streptavidin-conjugated enzymes. The detection process can be carried out within 2 h, allows the processing of large sample sizes and can potentially be automated. PMID:8774915

  13. Methods of plate pexophagy monitoring and positive selection for ATG gene cloning in yeasts.

    PubMed

    Stasyk, Oleh V; Nazarko, Taras Y; Sibirny, Andriy A

    2008-01-01

    Methods for colony assay of peroxisomal oxidases in yeasts provide a convenient and fast approach for monitoring peroxisome status. They have been used in several laboratories for the isolation of yeast mutants deficient in selective autophagic peroxisome degradation (pexophagy), catabolite repression of peroxisomal enzymes or mutants deficient in oxidases themselves. In this chapter, protocols for monitoring peroxisomal alcohol oxidase and amine oxidase directly in yeast colonies and examples of their application for mutant isolation are described. These methods were successfully utilized in several methylotrophic yeasts and the alkane-utilizing yeast Yarrowia lipolytica.

  14. A method for calculating strut and splitter plate noise in exit ducts: Theory and verification

    NASA Technical Reports Server (NTRS)

    Fink, M. R.

    1978-01-01

    Portions of a four-year analytical and experimental investigation relative to noise radiation from engine internal components in turbulent flow are summarized. Spectra measured for such airfoils over a range of chord, thickness ratio, flow velocity, and turbulence level were compared with predictions made by an available rigorous thin-airfoil analytical method. This analysis included the effects of flow compressibility and source noncompactness. Generally good agreement was obtained. This noise calculation method for isolated airfoils in turbulent flow was combined with a method for calculating transmission of sound through a subsonic exit duct and with an empirical far-field directivity shape. These three elements were checked separately and were individually shown to give close agreement with data. This combination provides a method for predicting engine internally generated aft-radiated noise from radial struts and stators, and annular splitter rings. Calculated sound power spectra, directivity, and acoustic pressure spectra were compared with the best available data. These data were for noise caused by a fan exit duct annular splitter ring, larger-chord stator blades, and turbine exit struts.

  15. Photothermal characterization of the gelation process in Gelidium robustum Agar

    NASA Astrophysics Data System (ADS)

    Freile-Pelegrín, Y.; Bante, J.; Alvarado-Gil, J. J.; Yánez-Limón, J. M.

    2005-06-01

    Agar is a hydrophilic colloid formed by polysaccharides, whose ability to form reversible gels simply by cooling hot aqueous solutions is the most important property and can be regarded as the prototype and model for all gelling systems. In this paper the evolution of the gelation process of agar obtained from algae of the species Gelidium robustum, using the photopyroelectric technique is reported. It is shown that thermal effusivity increase when the agar is cooled, reaching a maximum value around 37°C. The increase in thermal effusivity can be related to the increasing of the bondings in the gel as temperature decreases, reaching the maximum at the gelation point. The decrease of the thermal effusivity at lower temperature could be due to the syneresis process involving a gradual release of water after gelation.

  16. Fly agaric (Amanita muscaria) poisoning, case report and review.

    PubMed

    Satora, Leszek; Pach, Dorota; Butryn, Beata; Hydzik, Piotr; Balicka-Slusarczyk, Barbara

    2005-06-01

    Gathering and eating mushrooms and other plants containing psychoactive substances has become increasingly popular among young people experimenting with drugs. Dried fly agaric Amanita muscaria fruiting bodies were eaten by five young persons (18-21 years of age) at a party in order to evoke hallucinations. Visual and auditory hallucinations occurred in four of them, whereas a 18-year-old girl lost consciousness. The following morning, she went to the Clinic of Toxicology. Due to the fact that not all the active substances present in the fly agaric have been identified, and some of them have an effect after a period of latency, the patient was admitted for several days of observation during which check-up examinations were performed. After four days without any problems, she was discharged. The poisoning regressed with no organ complications. The remaining persons who had eaten the fly agaric were free from any complaints. PMID:15904689

  17. Development of a Flow Cytometry-Based Method for Rapid Detection of Escherichia coli and Shigella Spp. Using an Oligonucleotide Probe.

    PubMed

    Xue, Yong; Wilkes, Jon G; Moskal, Ted J; Williams, Anna J; Cooper, Willie M; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A

    2016-01-01

    Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts.

  18. Development of a Flow Cytometry-Based Method for Rapid Detection of Escherichia coli and Shigella Spp. Using an Oligonucleotide Probe.

    PubMed

    Xue, Yong; Wilkes, Jon G; Moskal, Ted J; Williams, Anna J; Cooper, Willie M; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A

    2016-01-01

    Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts. PMID:26913737

  19. Development of a Flow Cytometry-Based Method for Rapid Detection of Escherichia coli and Shigella Spp. Using an Oligonucleotide Probe

    PubMed Central

    Xue, Yong; Wilkes, Jon G.; Moskal, Ted J.; Williams, Anna J.; Cooper, Willie M.; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A.

    2016-01-01

    Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts. PMID:26913737

  20. Modal analysis of delaminated composite plates using the finite element method and damage detection via combined Ritz/2D-wavelet analysis

    NASA Astrophysics Data System (ADS)

    Gallego, A.; Moreno-García, P.; Casanova, Cesar F.

    2013-06-01

    Structural studies to find defects (in particular delaminations) in composite plates have been very prevalent in the Structural Health Monitoring field. The present work develops a new method to detect delaminations in CFRP (Carbon Fiber Reinforced Polymer) plates. In this paper the method is validated with numerical simulations, which come to support its adequacy for use with real acquisition data. This is done firstly through the implementation of a delaminated plate finite element. Using the classical lamination plate theory, delamination is considered in the kinematic equations through jump functions and additional degrees of freedom. The element allows the introduction of nd delaminations through its thickness. Classical QMITC (Quadrilateral Mixed Interpolation Tensorial Components) and DKQ (Discrete Kirchhoff Quadrilateral) elements are used for the membrane and bending FEM (Finite Element Method) formulation. Second, using the vibration modes obtained with the FEM, a damage location technique based on the variational Ritz method and Wavelet Analysis is proposed. The approach has the advantage of requiring only damaged modes and not the healthy ones. Both FEM simulations and Ritz/Wavelet damage detection schemes are applied in an orthotropic CFRP plate with the stacking sequence [0/90]3S. In addition, the influence of delamination thickness position, boundary conditions and added noise (in order to simulate experimental measures) was studied.

  1. Comparison of plate reader-based methods with fluorescence microscopy for measurements of intracellular calcium levels for the assessment of in vitro neurotoxicity.

    PubMed

    Meijer, Marieke; Hendriks, Hester S; Heusinkveld, Harm J; Langeveld, Wendy T; Westerink, Remco H S

    2014-12-01

    The intracellular calcium concentration ([Ca(2+)]i) is an important readout for in vitro neurotoxicity since calcium is critically involved in many essential neurobiological processes, including neurotransmission, neurodegeneration and neurodevelopment. [Ca(2+)]i is often measured with considerable throughput at the level of cell populations with plate reader-based assays or with lower throughput at the level of individual cells with fluorescence microscopy. However, these methodologies yield different quantitative and qualitative results. In recent years, we demonstrated that the resolution and sensitivity of fluorescence microscopy is superior compared to plate reader-based assays. However, it is currently unclear if the use of plate reader-based assays results in more 'false negatives' or 'false positives' in neurotoxicity screening studies. In the present study, we therefore compared a plate reader-based assay with fluorescence microscopy using a small test set of environmental pollutants consisting of dieldrin, lindane, polychlorinated biphenyl 53 (PCB53) and tetrabromobisphenol-A (TBBPA). Using single-cell fluorescence microscopy, we demonstrate that all test chemicals reduce the depolarization-evoked increase in [Ca(2+)]i, whereas lindane, PCB53 and TBBPA also increase basal [Ca(2+)]i, though via different mechanisms. Importantly, none of these effects were confirmed with the plate reader-based assay. We therefore conclude that standard plate reader-based methods are not sufficiently sensitive and reliable to measure the highly dynamic and transient changes in [Ca(2+)]i that occur during chemical exposure.

  2. Various methods for extracting forces on a moving plate using Time-Resolved Particle Image Velocimetry (TR-PIV)

    NASA Astrophysics Data System (ADS)

    Rival, D.; Schoenweitz, D.; Tropea, C.

    2009-11-01

    It is often very challenging or even impossible to measure the forces directly on swimming or flying animals. For this reason traditional control-volume methods are used to estimate the unsteady forces on the body in question. TR-PIV systems allow for the measurement of the full spatial and temporal velocity field in the control volume as well as along the bounding control surfaces. The corresponding pressure field can be integrated from the complete velocity-field data set. However, the measurement of the velocity field in the proximity of the body’s surface is at times cumbersome due to shadows and reflections. An alternate control-volume formulationfootnotetextJ. Z. Wu, Z.-L. Pan and X.-Y. Lu, ``Unsteady fluid-dynamic force solely in terms of control-surface integral,” Phys. of Fluids 17, 098102 (2005) eliminates the need for velocity measurements in the proximity of the body. This method has been tested and compared to the traditional control-volume technique for a generic pitching and plunging flat plate in a hover chamber. The advantages and disadvantages of these methods are discussed in the context of their measurement accuracy.

  3. A method combining immunocapture and PCR amplification in a microtiter plate for the detection of plant viruses and subviral pathogens.

    PubMed

    Nolasco, G; de Blas, C; Torres, V; Ponz, F

    1993-12-15

    A method for the detection of RNA viral and subviral plant pathogens was developed that combines pathogen partial purification by solid-phase adsorbed antibodies, reverse transcriptional-polymerase chain reaction (RT-PCR) and quantitation of the amplified products by fluorescence. The reverse transcription of the RNA is performed directly on the retained material without any previous thermal or chemical disruption of the virus particles. The whole procedure can be carried out in a microtiter plate. Its validity has been successfully confirmed for the detection of bean yellow mosaic virus, cherry leafroll virus, cucumber mosaic virus, citrus tristeza virus, grapevine fanleaf virus, potato leafroll virus, pepper mild mottle virus, and tomato spotted wilt virus, as well as the satellite RNA of cucumber mosaic virus and potato spindle tuber viroid. In this procedure virus-specific antibodies can be replaced by monoclonal antibodies against double-stranded RNA, thus offering the possibility of detection when no specific virus antibodies are available, or immunological methods are difficult to use (i.e., subviral pathogens like satellite-RNAs or viroids). The method described has the typical sensitivity of assays based on the polymerase chain reaction, it is not more laborious than ELISA, and an equivalent degree of automation is possible. PMID:8113346

  4. Sub-Plate Overlap Code Documentation

    NASA Technical Reports Server (NTRS)

    Taff, L. G.; Bucciarelli, B.; Zarate, N.

    1997-01-01

    An expansion of the plate overlap method of astrometric data reduction to a single plate has been proposed and successfully tested. Each plate is (artificially) divided into sub-plates which can then be overlapped. This reduces the area of a 'plate' over which a plate model needs to accurately represent the relationship between measured coordinates and standard coordinates. Application is made to non-astrographic plates such as Schmidt plates and to wide-field astrographic plates. Indeed, the method is completely general and can be applied to any type of recording media.

  5. Evaluation of Brilliance ESBL agar, a novel chromogenic medium for detection of extended-spectrum-beta- lactamase-producing Enterobacteriaceae.

    PubMed

    Huang, Te-Din; Bogaerts, Pierre; Berhin, Catherine; Guisset, Amelie; Glupczynski, Youri

    2010-06-01

    The aim of this study was to evaluate the performance of Brilliance ESBL agar (OX; Oxoid, Basingstoke, United Kingdom), a novel chromogenic agar for the selective isolation and the presumptive identification of extended-spectrum-beta-lactamase (ESBL)-producing Enterobacteriaceae. A panel of 200 clinical Gram-negative Enterobacteriaceae and nonfermenting isolates with defined resistance mechanisms was inoculated onto OX and onto ChromID ESBL agar (BM; bioMérieux, Marcy l'Etoile, France) chromogenic medium in the first part of the study to evaluate the growth selectivity and chromogenic features of these two media. Of the 156 Enterobacteriaceae challenge isolates, 8 fully susceptible isolates were inhibited, all 98 ESBL producers were detected, and 50 isolates harboring other resistance mechanisms were recovered on both chromogenic agars. In the second phase, 528 clinical samples (including 344 fecal specimens) were plated onto OX, BM, and MacConkey agar with a ceftazidime disk (MCC) for the screening of ESBL-producing Enterobacteriaceae. Growth on at least one medium was observed with 144 (27%) of the clinical samples screened. A total of 182 isolates, including 109 (60%) of Enterobacteriaceae, were recovered and 70 of these (from 59 specimens) were confirmed as ESBL-producing isolates. The sensitivities of MCC, BM, and OX were 74.6%, 94.9%, and 94.9%, respectively. The specificities of MCC, BM, and OX by specimens reached 94.9%, 95.5%, and 95.7%, respectively, when only colored colonies were considered on the two selective chromogenic media. The high negative predictive value (99.3%) found for OX suggests that this medium may constitute an excellent screening tool for the rapid exclusion of patients not carrying ESBL producers.

  6. A comparison of plate assay methods for detecting extracellular cellulase and xylanase activity.

    PubMed

    Meddeb-Mouelhi, Fatma; Moisan, Jessica Kelly; Beauregard, Marc

    2014-11-01

    Identification of microorganisms for the production of carbohydrolytic enzymes is extremely important given the increased demand for these enzymes in many industries. To this end, dye-polysaccharide interactions which provide a visual indication of polymer hydrolysis (clear zones or halos) have been used for decades. For the detection of extracellular cellulase or xylanase activity many laboratories use Gram's iodine as the chromogenic dye, as it is a more rapid initial screening method compared to the use of other dyes. Here, we compared Gram's iodine and Congo red as indicators of polysaccharide hydrolysis. We attempted to detect cellulase activity using carboxymethylcellulose, and xylanase activity using birchwood xylan, in fourteen uncharacterized bacteria isolated from wood chips. Our results indicate that Gram's iodine may lead to identification of false positives in a typical screening protocol and that Congo red allows for avoidance of such pitfall. Congo red allowed detection of cellulase activity from live microbial colonies but not Gram's iodine. To confirm this, detection of enzymatic activity was also assessed using cell-free enzyme preparations. Congo red was found to be reliable in detecting cellulase activity with isolated enzymes preparations. Under the same conditions, neither of these dyes detected xylanase activity, despite independent evidence of xylanase activity for one of the preparations. We detected xylanase activity for this particular enzyme preparation using a coloured derivative of xylan (Remazol Brillant Blue R-xylan adduct) that respond to xylan hydrolysis. Our results suggest that methods that rely on interactions between a dye (Congo red or Gram's iodine) and a polymeric substrate (carboxymethylcellulose or birchwood xylan) for indirect detection of hydrolysis may require the use of relevant controls and independent confirmation of enzymatic activities.

  7. Phene Plate (PhP) biochemical fingerprinting. A screening method for epidemiological typing of enterococcal isolates.

    PubMed

    Saeedi, B; Tärnberg, M; Gill, H; Hällgren, A; Jonasson, J; Nilsson, L E; Isaksson, B; Kühn, I; Hanberger, H

    2005-09-01

    Pulsed-field gel electrophoresis (PFGE) is currently considered the gold standard for genotyping of enterococci. However, PFGE is both expensive and time-consuming. The purpose of this study was to investigate whether the PhP system can be used as a reliable clinical screening method for detection of genetically related isolates of enterococci. If so, it should be possible to minimize the number of isolates subjected to PFGE typing, which would save time and money. Ninety-nine clinical enterococcal isolates were analysed by PhP (similarity levels 0.90-0.975) and PFGE (similarity levels < or =3 and < or =6 bands) and all possible pairs of isolates were cross-classified as matched or mismatched. We found that the probability that a pair of isolates (A and B) belonging to the same type according to PhP also belong to the same cluster according to PFGE, i.e. p(A(PFGE)=B(PFGE) * A(PhP)=B(PhP)), and the probability that a pair of isolates of different types according to PhP also belong to different clusters according to PFGE, i.e. p(A(PFGE) not equalB(PFGE) * A(PhP) not equalB(PhP)), was relatively high for E. faecalis (0.86 and 0.96, respectively), but was lower for E. faecium (0.51 and 0.77, respectively). The concordance which shows the probability that PhP and PFGE agree on match or mismatch was 86%-93% for E. faecalis and 54%-66% for E. faecium, which indicates that the PhP method may be useful for epidemiological typing of E. faecalis in the current settings but not for E. faecium.

  8. An agar gel enzyme assay (AGEA) for simple detection of Salmonella enteritidis antibodies in chicken sera.

    PubMed

    Kim, C J; Nagaraja, K V

    1991-01-01

    An agar gel enzyme assay (AGEA) was developed for the detection of antibodies to Salmonella enteritidis (SE). The assay was based on the ability of antibodies to diffuse through an agar gel and react with antigen coated on a polystyrene surface. The antigen-antibody reaction was then made visible by applying an enzyme-conjugated anti-immunoglobulin and the addition, subsequently, of a substrate-containing gel. The color change in circular zones was taken as the indication for the presence of antibodies. The present investigation reports identification of an antigen specific for SE and its use in the development of a relatively simple AGEA procedure. The results of AGEA were compared with those of conventional microagglutination (MA) test and serum plate (SP) test. The percentage agreement between MA and AGEA in positive serum sample was found to be 94.4%, and in negative serum samples it was found to be 88.8%. The present results suggest that the AGEA could be a very useful screening test for the detection of SE antibodies because the assay is inexpensive, specific and simple to perform without much equipment, and give results within a 3-hr period. PMID:1832368

  9. Abolition of Swarming of Proteus by p-Nitrophenyl Glycerin: Application to Blood Agar Media

    PubMed Central

    Williams, Fred D.

    1973-01-01

    Comparative plate counts were made of Staphylococcus aureus and Streptococcus pyogenes growing on blood agar supplemented with individual chemicals to abolish the swarming of Proteus. B-phenylethanol, sodium azide, and p-nitrophenyl glycerin (PNPG) were used as anti-swarm agents. Each anti-swarm agent effectively abolished swarming for 24 h, but azide failed to control swarming for longer periods of incubation. In addition, azide displayed growth inhibition towards the staphylococci and streptococci resulting in no hemolysis and reduced viable cell numbers with the streptococci. Phenylethanol showed reduced viable cell numbers with the streptococci and unreliable hemolytic reactions. At 0.1 to 0.3 mM, PNPG proved to be a superior anti-swarm agent in that it showed no growth inhibition and allowed normal hemolysis, but abolished swarming for extended periods of time. When laboratory strains of Streptococcus pneumoniae, Klebsiella pneumoniae, Pseudomonas aeruginosa. Listeria monocytogenes, and Vibrio cholerae were screened on a blood agar medium containing 0.1 mm PNPG, they displayed similar growth and hemolytic characteristics to the identical medium without PNPG. PMID:4715553

  10. Modal analysis of circular plates with radial side cracks and in contact with water on one side based on the Rayleigh-Ritz method

    NASA Astrophysics Data System (ADS)

    Si, X. H.; Lu, W. X.; Chu, F. L.

    2012-01-01

    In this paper, free vibrations of the baffled circular plates with radial side cracks and in contact with water on one side are investigated based on the Rayleigh-Ritz method. The completely free, simply supported and completely clamped boundary conditions are considered. Corner functions are introduced to describe the singularities at the crack tip. The motion of water is expressed by the velocity potential and the interaction between the water and the plate is derived in the form of an integral equation including the dynamic deformation of the cracked plate. The convergence studies are carried out and the numerical results show that the distinctions between the dry and wet mode shapes will be increased obviously excluding the first symmetric and antisymmetric modes when cracks appear. When the approximate methods based on the assumption that the wet modes are identical with the dry modes are adopted to calculate the eigenfrequencies, the errors of the results for cracked circular plates are larger than those for intact ones. The influences of the water on the symmetric and antisymmetric modes are different evidently, and the greatest reduction ratio of eigenfrequency and least difference between dry and wet mode are relative to the first symmetric mode. The verifications based on numerical simulation show that the proposed method is adequate for the investigation of free vibration of baffled circular plates with radial side cracks and in contact with water on one side.

  11. Is blood agar an alternative to sabouraud dextrose agar for the isolation of fungi in patients with mycotic keratitis.

    PubMed

    Reddy, Ashok Kumar; Brahmaiah, Upputuri; Narayen, Nitesh; Reddy, Ravi Kumar; Reddy, Rupak Kumar; Chitta, Meghraj; Prasad, Srinivas; Swarup, Rishi; Mohiuddin, Syed Maaz; Reddy, Madhukar; Aasuri, Murali K; Murthy, B S R; Bhide, Milind; Ahmed, Sajid

    2013-06-01

    To compare the blood agar (BA), sabouraud dextrose agar (SDA) and chocolate agar (CA) for the isolation of fungi in patients with mycotic keratitis. Corneal Scrapings of 229 patients with clinically diagnosed microbial keratitis were inoculated on BA, SDA, CA. The culture media were evaluated for the rate and time taken for the fungal growth. Seventy six of 229 patients had fungal keratitis. Fungus grew on BA in 60/76(78.9 %), on SDA in 76/76 (100 %), on CA in 40/76(52.6 %) patients. The fungi which grew on BA (60/76) also grown on SDA at the same time. The colony morphologies of different fungi were better on SDA than BA/CA. Among the different culture media, SDA is essential for the isolation fungi in patients with mycotic keratitis.

  12. Quantitative thin layer chromatography for the analysis of skin surface lipids. A time-saving method using a new TLC plate.

    PubMed

    Weissmann, A

    1979-07-30

    Recently a new thin layer chromatography plate (Whatman LK 6D) became available which is extremely easy to handle and permits highly reproducible qualitative and quantitative analysis. This plate proved to be of great value for the investigation of skin surface lipids. The use of a fatty acid methyl ester as an internal standard makes it unnecessary to employ additional gravimetrical or photometrical methods for quanitative lipid analysis. The method presented in this paper is simpler and requires much less time than alternative procedures and allows a large number of lipid samples to be processed simultaneously. PMID:475450

  13. A new method for analytical solution of inplane free vibration of rectangular orthotropic plates based on the analysis of infinite systems

    NASA Astrophysics Data System (ADS)

    Papkov, S. O.

    2016-05-01

    In this paper, a new method for in-plane free vibration analysis of rectangular orthotropic plate is presented. The cases for completely clamped and completely free plates are considered in detail. The boundary value problem is essentially reduced to infinite systems of linear algebraic equations. New mathematical theory and associated results are presented for investigating the asymptotic behavior of non-trivial solution of quasi-regular infinite system. By enhancing the theory, an effective and accurate algorithm for determining the natural frequencies and modes shapes vibrations is developed. The accuracy and computational efficiency of the method are demonstrated by examples.

  14. Isolation of Clostridium difficile from faecal specimens--a comparison of chromID C. difficile agar and cycloserine-cefoxitin-fructose agar.

    PubMed

    Carson, Kerry C; Boseiwaqa, Lusiana V; Thean, Sara K; Foster, Niki F; Riley, Thomas V

    2013-09-01

    The culture of toxigenic Clostridium difficile from stool specimens is still seen as the gold standard for the laboratory diagnosis of C. difficile infection (CDI). bioMérieux have released ChromID Cdiff chromogenic agar (CDIF) for the isolation and identification of C. difficile in 24 h. In this study, we compared CDIF to pre-reduced cycloserine-cefoxitin-fructose agar with sodium taurocholate (TCCFA) in the examination of glutamate dehydrogenase-positive faecal specimens that were either GeneOhm positive or negative, using direct culture or culture following alcohol shock. Direct culture on CDIF had a sensitivity of 100 % and recovery of 94 % while for TCCFA these were 87 % and 82 %, respectively. For GeneOhm-positive alcohol-shocked faecal samples, sensitivity and recovery on CDIF was similar to direct culture while on TCCFA they were about 10 % higher. For direct culture, there was a significant difference between growth on CDIF at 24 h and TCCFA at 48 h (P = 0.001) and between the two media at 48 h (P<0.001). A total of 142 strains of C. difficile were recovered in pure culture from all GeneOhm-positive samples used in this study and 11 (7.7 %) of these were A(-)B(-)CDT(-) and may represent mixed infections of toxigenic and non-toxigenic C. difficile. The most dominant ribotype was UK 014 (14.7 %) followed by 002 (11.9 %) and 020 (11.9 %), and 36 % of toxigenic isolates, including an A(-)B(+)CDT(-) strain, could not be assigned a UK ribotype. CDIF outperformed pre-reduced TCCFA by negating the need for alcohol shock treatment and by giving a time saving of 24 h in the isolation of C. difficile. CDIF plates were also more selective than TCCFA and C. difficile colonies were easy to identify and subculture prior to strain typing.

  15. Characteristics of rat megakaryocyte colonies and their progenitors in agar culture

    SciTech Connect

    Kellar, K.L.; Rolovic, Z.; Evatt, B.L.; Sewell, E.T.

    1985-11-01

    The characteristics of megakaryocyte colonies that develop from megakaryocyte progenitors of rat bone marrow stimulated by rat spleen-conditioned medium (SCM) in agar culture were investigated. Colony frequency was optimal on day 7 and increased relative to both the number of cells plated and the concentration of SCM used. Colonies were categorized as small cell and big cell. Small-cell colonies had a greater proliferative potential, with a mean of 25 cells/colony. Big-cell colonies averaged 15 cells/colony. The ratio of big-cell to small-cell colonies was 0.69 +/- 0.29. Granulocyte-macrophage colonies, which were also stimulated by SCM, accounted for 70% +/- 15% of the total colonies in the cultures. Cytocidal experiments with tritiated thymidine reduced megakaryocyte colony formation by 45% and granulocyte-macrophage colony formation by 21%. The properties of rat, mouse, and human megakaryocyte progenitors as assayed in vitro are compared.

  16. A Chlorhexidine- Agar Plate Culture Medium Protocol to Complement Standard Broth Culture of Mycobacterium tuberculosis

    PubMed Central

    Asmar, Shady; Chatellier, Sonia; Mirande, Caroline; van Belkum, Alex; Canard, Isabelle; Raoult, Didier; Drancourt, Michel

    2016-01-01

    The culture of Mycobacterium tuberculosis using parallel inoculation of a solid culture medium and a liquid broth provides the gold standard for the diagnosis of tuberculosis. Here, we evaluated a chlorhexidine decontamination-MOD9 solid medium protocol versus the standard NALC-NaOH-Bactec 960 MGIT protocol for the diagnosis of pulmonary tuberculosis by culture. Three-hundred clinical specimens comprising 193 sputa, 30 bronchial aspirates, 10 broncho-alveolar lavages, 47 stools, and 20 urines were prospectively submitted for the routine diagnosis of tuberculosis. The contamination rates were 5/300 (1.7%) using the MOD9 protocol and 17/300 (5.7%) with the Bactec protocol, respectively (P < 0.05, Fisher exact test). Of a total of 50 Mycobacterium isolates (48 M. tuberculosis and two Mycobacterium abscessus) were cultured. Out of these 50, 48 (96%) isolates were found using the MOD9 protocol versus 35 (70%) when using the Bactec protocol (P < 0.05, Fisher exact test). The time to positivity was 10.1 ± 3.9 days versus 14.7 ± 7.3 days, respectively, (P < 0.05, Student’s t-test). These data confirmed the usefulness of parallel inoculation of a solid culture medium with broth for the recovery of M. tuberculosis in agreement with current recommendations. More specifically, chlorhexidine decontamination and inoculation of the MOD9 solid medium could be proposed to complement the standard Bactec 960 MGIT broth protocol. PMID:26834733

  17. A Chlorhexidine- Agar Plate Culture Medium Protocol to Complement Standard Broth Culture of Mycobacterium tuberculosis.

    PubMed

    Asmar, Shady; Chatellier, Sonia; Mirande, Caroline; van Belkum, Alex; Canard, Isabelle; Raoult, Didier; Drancourt, Michel

    2016-01-01

    The culture of Mycobacterium tuberculosis using parallel inoculation of a solid culture medium and a liquid broth provides the gold standard for the diagnosis of tuberculosis. Here, we evaluated a chlorhexidine decontamination-MOD9 solid medium protocol versus the standard NALC-NaOH-Bactec 960 MGIT protocol for the diagnosis of pulmonary tuberculosis by culture. Three-hundred clinical specimens comprising 193 sputa, 30 bronchial aspirates, 10 broncho-alveolar lavages, 47 stools, and 20 urines were prospectively submitted for the routine diagnosis of tuberculosis. The contamination rates were 5/300 (1.7%) using the MOD9 protocol and 17/300 (5.7%) with the Bactec protocol, respectively (P < 0.05, Fisher exact test). Of a total of 50 Mycobacterium isolates (48 M. tuberculosis and two Mycobacterium abscessus) were cultured. Out of these 50, 48 (96%) isolates were found using the MOD9 protocol versus 35 (70%) when using the Bactec protocol (P < 0.05, Fisher exact test). The time to positivity was 10.1 ± 3.9 days versus 14.7 ± 7.3 days, respectively, (P < 0.05, Student's t-test). These data confirmed the usefulness of parallel inoculation of a solid culture medium with broth for the recovery of M. tuberculosis in agreement with current recommendations. More specifically, chlorhexidine decontamination and inoculation of the MOD9 solid medium could be proposed to complement the standard Bactec 960 MGIT broth protocol. PMID:26834733

  18. Use of modified blood agar plate for identification of pathogenic campylobacter species at Mymensingh Medical College .

    PubMed

    Sarkar, S R; Hossain, M A; Pual, S K; Mahmud, M C; Ray, N C; Haque, N

    2014-10-01

    This cross sectional study was carried out from July 2011 to June 2012 in the Department of Microbiology, Mymensingh Medical College to diagnose etiology of diarrhea caused by Campylobacter species. A total of 200 clinically diagnosed diarrheal pediatric patients were included in this study. Among the 200 stool specimens evaluated, 23(11.5%) samples were positive for Campylobacter species, isolation rate was 15(65.2%) in upto 1 year age group and 08(34.7%) in more than 1 year age group. Among 23 positive cases, 20(86.95%) were C. jejuni and 03(13.05%) were C. coli. The prevalence of Campylobacter infection found in the present study was higher below 1 year age group and was very much close to other countries of this Sub continent.

  19. Evaluation of the spiral plating method for the enumeration of microorganisms throughout the manufacturing and ripening of a raw goat's milk cheese.

    PubMed

    Alonso-Calleja, Carlos; Carballo, Javier; Capita, Rosa; Bernardo, Ana; García-López, María Luisa

    2002-02-01

    A statistical comparison of the spiral plate count (SPLPC) and the standard plate count (SPC) methods for enumeration of microorganisms in raw goat's milk cheese throughout its manufacturing and ripening was carried out. Enumeration of mesophiles, lactic acid bacteria (presumptive lactococci, presumptive leuconostocs, and presumptive lactobacilli), Micrococcaceae, Enterobacteriaceae, and molds and yeasts was carried out for milk, curd, and 2-, 5-, 10-, 17-, and 27-day-old cheeses. Average counts for the SPLPC and SPC methods differed by less than half of a log cycle for all microbial groups studied (range of difference, -0.1386 [mesophiles] to +0.4397 [presumptive lactobacilli]). The results of the SPLPC method compared favorably with the results of the SPC procedure for mesophiles, presumptive lactococci, presumptive leuconostocs, Enterobacteriaceae, and molds and yeasts (the variance between replicate platings was close to 0.005, and correlation coefficients were >0.9). Correlation coefficients were lower for Micrococcaceae (r = 0.824) and presumptive lactobacilli (r = 0.670). Analysis of variance showed that the plating method was a significant factor (P < 0.05) for presumptive lactobacilli counts. In general, results from the SPLPC method compared favorably with results from SPC procedure in the enumeration of microorganisms in goat cheese throughout its manufacturingand ripening processes. However, the suitability of the SPLPC method depends mainly on the microbial group studied.

  20. Improving agar electrospinnability with choline-based deep eutectic solvents

    Technology Transfer Automated Retrieval System (TEKTRAN)

    One percent agar (% wt) was dissolved in the deep eutectic solvent (DES), (2-hydroxyethyl) trimethylammonium chloride/urea at a 1:2 molar ratio, and successfully electrospun into nanofibers. An existing electrospinning set-up, operated at 50 deg C, was adapted for use with an ethanol bath to collect...

  1. Calculations of Lamb wave band gaps and dispersions for piezoelectric phononic plates using mindlin's theory-based plane wave expansion method.

    PubMed

    Hsu, Jin-Chen; Wu, Tsung-Tsong

    2008-02-01

    Based on Mindlin's piezoelectric plate theory and the plane wave expansion method, a formulation is proposed to study the frequency band gaps and dispersion relations of the lower-order Lamb waves in two-dimensional piezoelectric phononic plates. The method is applied to analyze the phononic plates composed of solid-solid and airsolid constituents with square and triangular lattices, respectively. Factors that influence the opening and width of the complete Lamb wave gaps are identified and discussed. For solid/solid phononic plates, it is suggested that the filling material be chosen with larger mass density, proper stiffness, and weak anisotropic factor embedded in a soft matrix in order to obtain wider complete band gaps of the lower-order Lamb waves. By comparing to the calculated results without considering the piezoelectricity, the influences of piezoelectric effect on Lamb waves are analyzed as well. On the other hand, for air/solid phononic plates, a background material itself with proper anisotropy and a high filling fraction of air may favor the opening of the complete Lamb wave gaps.

  2. A correlation method to predict the surface pressure distribution of an infinite plate or a body of revolution from which a jet is issuing

    NASA Technical Reports Server (NTRS)

    Perkins, S. C., Jr.; Mendenhall, M. R.

    1980-01-01

    A correlation method to predict pressures induced on an infinite plate by a jet exhausting normal to the plate into a subsonic free stream was extended to jets exhausting at angles to the plate and to jets exhausting normal to the surface of a body revolution. The complete method consisted of an analytical method which models the blockage and entrainment properties of the jet and an empirical correlation which accounts for viscous effects. For the flat plate case, the method was applicable to jet velocity ratios up to ten, jet inclination angles up to 45 deg from the normal, and radial distances up to five diameters from the jet. For the body of revolution case, the method was applicable to a body at zero degrees angle of attack, jet velocity ratios 1.96 and 3.43, circumferential angles around the body up to 25 deg from the jet, axial distances up to seven diameters from the jet, and jet-to-body diameter ratios less than 0.1.

  3. Evaluation of Trans-Vag Broth, Colistin-Nalidixic Agar, and CHROMagar StrepB for Detection of Group B Streptococcus in Vaginal and Rectal Swabs from Pregnant Women in South Africa

    PubMed Central

    Kwatra, Gaurav; Madhi, Shabir A.; Cutland, Clare L.; Buchmann, Eckhart J.

    2013-01-01

    Maternal vaginal colonization with group B streptococcus (GBS) is a major risk factor for invasive GBS infection in newborns. The CDC-recommended method for detecting GBS colonization is to culture vaginal and rectal swabs in a selective broth followed by subculture on blood agar or a selective medium. A high incidence of antimicrobial resistance in the fecal microflora can compromise the recovery of GBS from the selective broth. Here, we compared CHROMagar StrepB (CA), Columbia colistin-nalidixic agar (CNA), and Trans-Vag selective broth enrichment for the isolation of GBS from 130 vaginal and 130 rectal swabs from pregnant women. The swabs were randomized for plating first on either CA or CNA, and they then were inoculated in Trans-Vag broth. GBS was cultured from 37.7% of the vaginal swabs and 33.1% of the rectal swabs. There were no differences in the detection rates for the vaginal swabs between CA (31.5%), CNA (26.2%), and the selective broth (30.0%). The sensitivities in relation to a composite score were 83.7%, 69.4%, and 79.6%, respectively. However, recovery of GBS from the rectal swabs was significantly higher from CA (29.2%; P < 0.0001) and CNA (23.8%; P = 0.002) than from the selective broth (9.2%). The sensitivities were 88.4%, 72.1%, and 27.9%, respectively. The order of plating on the solid medium was significant (P = 0.003), with GBS detection rates of 30.8% and 24.6% when swabs were plated first and second, respectively. These findings show that a selective broth is not suitable for the recovery of GBS from rectal swabs in settings such as ours, due to masking of the GBS colonies by persistent microflora. PMID:23698527

  4. Evaluation of Trans-Vag broth, colistin-nalidixic agar, and CHROMagar StrepB for detection of group B Streptococcus in vaginal and rectal swabs from pregnant women in South Africa.

    PubMed

    Kwatra, Gaurav; Madhi, Shabir A; Cutland, Clare L; Buchmann, Eckhart J; Adrian, Peter V

    2013-08-01

    Maternal vaginal colonization with group B streptococcus (GBS) is a major risk factor for invasive GBS infection in newborns. The CDC-recommended method for detecting GBS colonization is to culture vaginal and rectal swabs in a selective broth followed by subculture on blood agar or a selective medium. A high incidence of antimicrobial resistance in the fecal microflora can compromise the recovery of GBS from the selective broth. Here, we compared CHROMagar StrepB (CA), Columbia colistin-nalidixic agar (CNA), and Trans-Vag selective broth enrichment for the isolation of GBS from 130 vaginal and 130 rectal swabs from pregnant women. The swabs were randomized for plating first on either CA or CNA, and they then were inoculated in Trans-Vag broth. GBS was cultured from 37.7% of the vaginal swabs and 33.1% of the rectal swabs. There were no differences in the detection rates for the vaginal swabs between CA (31.5%), CNA (26.2%), and the selective broth (30.0%). The sensitivities in relation to a composite score were 83.7%, 69.4%, and 79.6%, respectively. However, recovery of GBS from the rectal swabs was significantly higher from CA (29.2%; P<0.0001) and CNA (23.8%; P=0.002) than from the selective broth (9.2%). The sensitivities were 88.4%, 72.1%, and 27.9%, respectively. The order of plating on the solid medium was significant (P=0.003), with GBS detection rates of 30.8% and 24.6% when swabs were plated first and second, respectively. These findings show that a selective broth is not suitable for the recovery of GBS from rectal swabs in settings such as ours, due to masking of the GBS colonies by persistent microflora.

  5. Infrared thermography analysis of thermal diffusion induced by RF magnetic field on agar phantoms loaded with magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Bante-Guerra, Jose; Macías, J. D.; Caballero-Aguilar, L.; Vales-Pinzón, C.; Alvarado-Gil, J. J.

    2013-02-01

    Recently, several treatments for fighting malignant tumors have been designed. However these procedures have well known inconveniences, depending on their applicability, tumor size and side effects, among others. Magnetic hyperthermia is a safe, non-invasive method for cancer therapy. This treatment is applied via elevation of target tissue temperature by dissipation of heat from Magnetic Nanoparticles (MNPs), previously located within the tumor. The induction of heat causes cell death and therefore the removal of the tumor. In this work the thermal diffusion in phantoms of agar loaded with magnetic nanoparticles (MNPs) is studied using the infrared thermography technique, which is widely used in biology/medicine (e.g. skin temperature mapping). Agar is one of the materials used to simulate different types of body tissues, these samples are known as "phantoms". Agar is of natural origin, low cost and high degree of biocompatibility. In this work the agar gel was embedded with MNPs by coprecipitation and placed in an alternating magnetic field radiation. As a consequence, the energy from the radiation source is dissipated as heat and then transferred from the MNP to the gel, increasing its temperature. For the temperature analysis, the samples of agar gel were stimulated by RF magnetic field generated by coils. Heating was measured with infrared thermography using a Thermovision A20M infrared camera. Thermographic images allowed obtaining the dependence of thermal diffusion in the phantom as a function of the magnitude of the applied RF magnetic field and the load of magnetic particles.

  6. Agar-agar entrapment increases the stability of endo-β-1,4-xylanase for repeated biodegradation of xylan.

    PubMed

    Bibi, Zainab; Shahid, Faiza; Ul Qader, Shah Ali; Aman, Afsheen

    2015-04-01

    Microbial xylanases, specially endo-β-1,4-xylanase catalyzes the hydrolysis of xylan, is considered one of the most significant hydrolases. It has numerous applications but most extensively is utilized in paper and pulp industry as a bio-bleaching agent. Immobilization technique is comprehensively studied with the expectation of modifying and improving enzyme stability and characteristics for commercial purposes. Currently, matrix entrapment technique is applied to immobilize endo-β-1,4-xylanase within agar-agar gel beads produced by Geobacillus stearothermophilus KIBGE-IB29. Maximal enzyme immobilization yield was achieved at 2.5% of agar-agar concentration. Optimized conditions demonstrated an increase in the optimal reaction time from 05 min to 30 min and incubation temperature from 50 °C to 60 °C with reference to free enzyme whereas; no effect was observed for optimum pH. Entrapment technique uniquely changed the kinetic parameters of immobilized endo-β-1,4-xylanase (Km: 0.5074 mg min(-1) to 0.5230 mg min(-1) and Vmax: 4773 U min(-1) to 968 U min(-1)) as compared to free enzyme. However, immobilized enzyme displayed broad thermal stability and retained 79.0% of its initial activity at 80 °C up to 30 min whereas; free enzyme completely lost its activity at this temperature. With respect to economic feasibility, the immobilized enzyme showed impressive recycling efficiency up to six reaction cycles. PMID:25603143

  7. Thermal-induced ageing of agar solutions: impact on the structural and mechanical properties of agar gels

    NASA Astrophysics Data System (ADS)

    Mao, Bosi; Bentaleb, Ahmed; Louerat, Frédéric; Divoux, Thibaut; Snabre, Patrick

    Numerous hydrogels are prepared by cooling down to ambient temperature, aqueous polymer solutions brought to a boil. Although the incubation time of the polymer solution at such a high temperature could be used as a tuning parameter, its impact on the subsequent gelation has been poorly investigated. Here we study the effect of prolonged heating at 80°C on a 1.5% wt solution of agar, a natural polysaccharide. The incubation time is varied from a few hours up to five days. We show that the agar sol. continuously degrades as the result of both the hydrolysis and the intermolecular oxidation of the polymer chains. Furthermore, electronic microscopy and X-ray diffraction experiments reveal that gels formed from older agar sols display an increasingly coarser microstructure composed of micron-sized aggregated pieces of polysaccharides, in contrast with the fibrous-like structure of gels made from fresh sols. Along with structural changes prolonged incubation time leads to weaker gels of lower shear elastic modulus. Finally, macro-indentation experiments coupled to direct visualization show that increasing the incubation time of the agar sol. decreases the yield strain of the gel by a factor of three, while the rupture scenario turns continuously from brittle to ductile-like. Acknowledging funding from BioMérieux & CNRS.

  8. Reduction of astrometric plates

    NASA Technical Reports Server (NTRS)

    Stock, J.

    1984-01-01

    A rapid and accurate method for the reduction of comet or asteroid plates is described. Projection equations, scale length correction, rotation of coordinates, linearization, the search for additional reference stars, and the final solution are examined.

  9. A study of narrow gap laser welding for thick plates using the multi-layer and multi-pass method

    NASA Astrophysics Data System (ADS)

    Li, Ruoyang; Wang, Tianjiao; Wang, Chunming; Yan, Fei; Shao, Xinyu; Hu, Xiyuan; Li, Jianmin

    2014-12-01

    This paper details a new method that combines laser autogenous welding, laser wire filling welding and hybrid laser-GMAW welding to weld 30 mm thick plate using a multi-layer, multi-pass process. A “Y” shaped groove was used to create the joint. Research was also performed to optimize the groove size and the processing parameters. Laser autogenous welding is first used to create the backing weld. The lower, narrowest part of the groove is then welded using laser wire filling welding. Finally, the upper part of the groove is welded using laser-GMAW hybrid welding. Additionally, the wire feeding and droplet transfer behaviors are observed by high speed photography. The two main conclusions from this work are: the wire is often biased towards the side walls, resulting in a lack of fusion at the joint and the creation of other defects for larger groove sizes. Additionally, this results in the droplet transfer behavior becoming unstable, leading to a poor weld appearance for smaller groove sizes.

  10. Investigation of the Flow Structure on a Flat Plate Induced by Unsteady Plasma Actuation with DNS Methods

    NASA Astrophysics Data System (ADS)

    Yu, Jianyang; Chen, Fu; Liu, Huaping; Song, Yanping

    2015-12-01

    An investigation into the flow characteristic on a flat plate induced by an unsteady plasma was conducted with the methods of direct numerical simulations (DNS). A simplified model of dielectric barrier discharge (DBD) plasma was applied and its parameters were calibrated with the experimental results. In the simulations, effects of the actuation frequency on the flow were examined. The instantaneous flow parameters were also drawn to serve as a detailed study on the behavior when the plasma actuator was applied to the flow. The result shows that induced by the unsteady actuation, a series of vortex pairs which showed dipole formation and periodicity distribution were formed in the boundary layer. The production of these vortex pairs indicated a strong energy exchange between the main flow and the boundary layer. They moved downstream under the action of the free stream and decayed under the influence of the fluid viscosity. The distance of the neighboring vortices was found to be determined by the actuation frequency. Interaction of the neighboring vortices would be ignored when the actuation frequency was too small to make a difference. supported by the Foundation for Innovative Research Groups of National Natural Science Foundation of China (No. 51121004) and National Natural Science Foundation of China (No. 50976026)

  11. A handy approximate solution for a squeezing flow between two infinite plates by using of Laplace transform-homotopy perturbation method.

    PubMed

    Filobello-Nino, Uriel; Vazquez-Leal, Hector; Cervantes-Perez, Juan; Benhammouda, Brahim; Perez-Sesma, Agustin; Hernandez-Martinez, Luis; Jimenez-Fernandez, Victor Manuel; Herrera-May, Agustin Leobardo; Pereyra-Diaz, Domitilo; Marin-Hernandez, Antonio; Huerta Chua, Jesus

    2014-01-01

    This article proposes Laplace Transform Homotopy Perturbation Method (LT-HPM) to find an approximate solution for the problem of an axisymmetric Newtonian fluid squeezed between two large parallel plates. After comparing figures between approximate and exact solutions, we will see that the proposed solutions besides of handy, are highly accurate and therefore LT-HPM is extremely efficient.

  12. A handy approximate solution for a squeezing flow between two infinite plates by using of Laplace transform-homotopy perturbation method.

    PubMed

    Filobello-Nino, Uriel; Vazquez-Leal, Hector; Cervantes-Perez, Juan; Benhammouda, Brahim; Perez-Sesma, Agustin; Hernandez-Martinez, Luis; Jimenez-Fernandez, Victor Manuel; Herrera-May, Agustin Leobardo; Pereyra-Diaz, Domitilo; Marin-Hernandez, Antonio; Huerta Chua, Jesus

    2014-01-01

    This article proposes Laplace Transform Homotopy Perturbation Method (LT-HPM) to find an approximate solution for the problem of an axisymmetric Newtonian fluid squeezed between two large parallel plates. After comparing figures between approximate and exact solutions, we will see that the proposed solutions besides of handy, are highly accurate and therefore LT-HPM is extremely efficient. PMID:25157331

  13. Retrospective study of two fixation methods for 4-corner fusion: Shape-memory staple vs. dorsal circular plate.

    PubMed

    Le Corre, A; Ardouin, L; Loubersac, T; Gaisne, E; Bellemère, P

    2015-12-01

    The purpose of this study was to compare the results of two groups of patients with four-corner fusion, one group fixed with shape-memory staples and the other with locked circular plates. This retrospective study compared 52 wrists operated for scaphoid excision and four-corner fusion between 2005 and 2011. The arthrodesis was ensured by a shape-memory quadripodal staple (4Fusion(®), Memometal™) in 37 cases and a locking dorsal circular plate (Xpode(®), Biotech Ortho™) in 15 cases. In the staple group, the mean age was 58.5 years and the average follow-up was 4.3 years. In the circular plate group, the mean age was 58.6 years and the average follow-up was 3.1 years. Pain, range of motion, grip strength, functional scores (QuickDASH and PWRE), fusion of the midcarpal joint, complications (implant fracture and reoperation) and patients' satisfaction were used as outcome measures. There was no pain in 43% of patients in the staple group and 40% of patients in the circular plate group at the follow-up; range of motion and functional scores were similar in both groups. Seventy-five percent of patients in the staple group were satisfied or very satisfied versus 60% in the circular plate group. The implant broke in 24.3% of cases in the staple group and 60% in the circular plate group. Reoperation was needed in 18% of the staple cases and 14% of the plate cases. There was no difference between the implants in terms of pain, range of motion, functional scores and patient satisfactory. The implant fracture rate in the plate group was high. This study brings into question implant reliability for the four-corner fusion procedure.

  14. Natural frequencies of arbitrarily shaped plates using the Rayleigh-Ritz method together with natural co-ordinate regions and normalized characteristic orthogonal polynomials

    NASA Astrophysics Data System (ADS)

    Geannakakes, G. N.

    1995-05-01

    A Rayleigh-Ritz method mapping arbitrarily shaped plates on to a natural co-ordinate plane using serendipity functions is presented. The displacement function uses normalized beam characteristic orthogonal polynomials. The kinetic and strain energy equations are mapped from Cartesian co-ordinates to natural co-ordinates and the Rayleigh coefficient is minimized. Flexural free vibration analyses of various shaped plates is performed. Results are in excellent agreement with those found in the literature. This paper corrects the theory previously presented on this topic.

  15. Qualitative and quantitative agar invasion test based on bacterial colony/biofilm.

    PubMed

    Corcuera, María Teresa; Gómez-Aguado, Fernando; Gómez-Lus, María Luisa; Ramos, Carmen; de la Parte, María Antonia; Alonso, María José; Prieto, José

    2013-09-01

    Invasion of the culture medium is a feature frequently studied in yeasts, in which it has been related to a greater virulence, but it is practically unknown in bacteria. Recently, it has been demonstrated that several clinically relevant bacterial species were also able of invading agar media, so it was necessary to design a microbiological assay to study the expression of this character in bacteria. Accordingly, a bacterial agar invasion test based on colony/biofilm development was designed, which allows qualitative and quantitative characterization of bacterial growth into the agar culture medium. Once the culture conditions were optimized, the test was applied to 90 strains from nine bacterial species, validating its usefulness for differentiating invasive strains (positive) from those non invasive (negative). The test also allows sorting invasive strains according to agar invasion intensity (low, moderate, high) and topographic invasion pattern (peripheral, homogeneous, mixed). Moreover, an image analysis routine to quantify the invasion was developed. Implemented method enables direct measuring of two invasion parameters (invasion area and number of invasion dots), automated calculation of three relative variables (invasion relative area, invasion dots relative density, and invasion dot average area), and the establishment of strain specific frequency histograms. This new methodology is simple, fast, reproducible, objective, inexpensive and can be used to study a great number of specimens simultaneously, all of which make it suitable for incorporation to the routine of any microbiology laboratory. It could also be a useful tool for additional studies related to clinical aspects of bacterial isolates such as virulence and antimicrobial response.

  16. Evaluation of three decarboxylating agar media to detect histamine and tyramine-producing bacteria in ripened sausages.

    PubMed

    Roig-Sagués, A X; Hernàndez-Herrero, M M; López-Sabater, E I; Rodríguez-Jerez, J J; Mora-Ventura, M T

    1997-11-01

    Histidine- and tyrosine-decarboxylase activity of 175 strains of bacteria isolated from eight retail samples of Spanish ripened sausages was tested in three decarboxylating agars (Niven medium, Joosten and Northolt medium and modified decarboxylating agar of Maijala) and confirmed by an enzymic method (histamine) and thin-layer chromatography (tyramine). Enterobacteria and pseudomonads showed the highest percentage of positive responses to histamine and tyramine in the three decarboxylating agars, but only enterobacteria were subsequently confirmed as histamine-producing. Confirmed tyramine-producing strains were all identified as enterococci or lactic acid bacteria. The medium described by Joosten and Northolt was more sensitive and faster at detecting tyramine-producing microorganisms. However, all three media failed to detect one histamine-positive strain of lactic acid bacteria used as a control.

  17. STUDIES ON THE BACTERIOPHAGE OF D'HERELLE : III. SOME OF THE FACTORS DETERMINING THE NUMBER AND SIZE OF PLAQUES OF BACTERIAL LYSIS ON AGAR.

    PubMed

    Bronfenbrenner, J J; Korb, C

    1925-09-30

    The experiments reported above confirm the fact that lytic principle is distributed in active solution in a state of indivisible units. This permits its quantitative evaluation by serial dilution, as well as by plating on agar. The latter method, however, often gives readings considerably lower than those obtained by the broth dilution method of titration. By varying the concentration of agar it has been possible to show that the discrepancy is due to adsorption of the lytic agent on agar. When the concentration of the latter is increased from 0.3 per cent to 2.5 per cent the number of plaques of lysis is reduced more than 100 times. At the same time the average size of the plaques also decreases approximately to one-tenth of the original. The size, as well as the number of plaques, has been found to depend also on the condition of the culture employed in titration. Thus, when the culture exposed to the action of lytic agent is composed of young susceptible bacteria, the greater the concentration of bacteria, the smaller the plaques. When the culture is composed partly of young and partly of old susceptible bacteria, both the size and the number of the plaques are diminished with the increase in the relative concentration of old bacteria. On the other hand, presence in the culture of resistant bacteria does not affect either the size or the number of the plaques so long as the relative concentration of susceptible bacteria in the culture is sufficient to allow formation of them. The plaques appearing in the presence of a high concentration of resistant variants in the culture are relatively indistinct owing to overgrowth. Under carefully controlled conditions the size of plaques is found to be determined by the character of the lytic filtrate. Thus in the case of lytic agents which act upon more than one bacterial species the size of the plaques remains constant, irrespective of the bacterial substratum used for the production of the active filtrate.

  18. 3M Petrifilm Staph Express Count plate method for the enumeration of Staphylococcus aureus in selected types of meat, seafood, and poultry: collaborative study.

    PubMed

    McMahon, Wendy A; Aleo, Victoria A; Schultz, Ann M; Horter, Barbara L; Lindberg, Kathryn G

    2003-01-01

    The 3M Petrifilm Staph Express Count plate method was compared with AOAC Official Method 975.55 for the enumeration of Staphylococcus aureus in selected foods. Four foods--cooked, diced chicken; cured ham; smoked salmon; and pepperoni--were analyzed for S. aureus by 12 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample, a low inoculation level, a medium inoculation level, and a medium inoculation level with background flora, each in duplicate. The mean log10 counts for the methods were comparable for all 4 foods. The repeatability and reproducibility variances of the 24 h Petrifilm Staph Express Count plate method were similar to those of the 72 h standard method.

  19. 3M Petrifilm Staph Express Count plate method for the enumeration of Staphylococcus aureus in selected types of processed and prepared foods: collaborative study.

    PubMed

    Silbernagel, Karen M; Jechorek, Robert P; Carver, Charles N; Horter, Barbara L; Lindberg, Kathryn G

    2003-01-01

    The 3M Petrifilm Staph Express Count plate method was compared with AOAC Official Method 975.55 for the enumeration of Staphylococcus aureus in selected foods. Five foods--frozen lasagna, custard, frozen mixed vegetables, frozen hashbrowns, and frozen batter-coated mushrooms--were analyzed for S. aureus by 13 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample, a low inoculation level, a medium inoculation level, and a medium inoculation level with background flora, each in duplicate. The mean log10 counts for the methods were comparable for all 5 foods. The repeatability and reproducibility variances of the 24 h Petrifilm Staph Express Count plate method were similar to those of the 72 h standard method.

  20. Estimation method for serial dilution experiments.

    PubMed

    Ben-David, Avishai; Davidson, Charles E

    2014-12-01

    Titration of microorganisms in infectious or environmental samples is a corner stone of quantitative microbiology. A simple method is presented to estimate the microbial counts obtained with the serial dilution technique for microorganisms that can grow on bacteriological media and develop into a colony. The number (concentration) of viable microbial organisms is estimated from a single dilution plate (assay) without a need for replicate plates. Our method selects the best agar plate with which to estimate the microbial counts, and takes into account the colony size and plate area that both contribute to the likelihood of miscounting the number of colonies on a plate. The estimate of the optimal count given by our method can be used to narrow the search for the best (optimal) dilution plate and saves time. The required inputs are the plate size, the microbial colony size, and the serial dilution factors. The proposed approach shows relative accuracy well within ±0.1log10 from data produced by computer simulations. The method maintains this accuracy even in the presence of dilution errors of up to 10% (for both the aliquot and diluent volumes), microbial counts between 10(4) and 10(12) colony-forming units, dilution ratios from 2 to 100, and plate size to colony size ratios between 6.25 to 200.

  1. How do microorganisms influence trace element uptake by plants? Screening in an agar model rhizosphere.

    NASA Astrophysics Data System (ADS)

    Marchetti, M.; Robinson, B. H.; Evangelou, M. W. H.; Vachey, A.; Schwitzguebel, J. P.; Bernier-Latmani, R.; Schulin, R.

    2009-04-01

    Trace elements (TE) are essential for humans and plants, but they may be toxic if their concentration is too high. For this reason, the management of TE in soils is very important. In some cases it may be necessary to increase the uptake of nutrients or TE by plants, for example in a biofortification perspective. Conversely, in some other cases TE uptake by plants should be decreased, for instance to avoid heavy metals entering the food chain via edible crops. Microorganisms living in the rhizosphere affect trace element (TE) uptake by plants. However, due to the complexity of this space and the variety of microorganisms that occur there, it is difficult to isolate the effect of any particular strain. To overcome this hurdle, we developed a system in which we grew plants under sterile conditions in agar and inoculated their rhizosphere with a single, well-defined microbial strain. For many years, agar has been used as a growth substrate for microorganisms and plant tissues. It is cheap, easy to use, and can be autoclaved to ensure its sterility. Because of its widespread use, an experiment conducted using this substrate can be reproduced under the same conditions in any laboratory. In contrast to soil, there is little interaction between the trace elements and the agar matrix. There are many studies investigating the influence of microorganisms on TE uptake by plants. However, so far only a small variety of microorganisms has been tested on few plant species. Therefore, the first objective of our research was to develop a method to rapidly screen a large variety of microorganisms on various plant species. Once this goal was achieved, we sought to study the effect of single, well-defined microbial strains on TE uptake by sunflower and wheat. The substrate for plants growth was a 10% agar solution prepared with modified Hoagland's solution and a TE solution containing 1 mg/kg Pb and molar equivalents of Cu, Ni and Zn. The agar solution was autoclaved and poured into

  2. Spray method for recovery of heat-injured Salmonella Typhimurium and Listeria monocytogenes.

    PubMed

    Back, Kyeong-Hwan; Kim, Sang-Oh; Park, Ki-Hwan; Chung, Myung-Sub; Kang, Dong-Hyun

    2012-10-01

    Selective agar is inadequate for supporting recovery of injured cells. During risk assessment of certain foods, both injured and noninjured cells must be enumerated. In this study, a new method (agar spray method) for recovering sublethally heat-injured microorganisms was developed and used for recovery of heat-injured Salmonella Typhimurium and Listeria monocytogenes. Molten selective agar was applied as an overlay to presolidified nonselective tryptic soy agar (TSA) by spray application. Heat-injured cells (55°C for 10 min in 0.1% peptone water or 55°C for 15 min in sterilized skim milk) were inoculated directly onto solidified TSA. After a 2-h incubation period for cell repair, selective agar was applied to the TSA surface with a sprayer, and the plates were incubated. The recovery rate for heat-injured Salmonella Typhimurium and L. monocytogenes with the spray method was compared with the corresponding rates associated with TSA alone, selective media alone, and the conventional overlay method (selective agar poured on top of resuscitated cells grown on TSA and incubated for 2 h). No significant differences (P > 0.05) were found in pathogen recovery obtained with TSA, the overlay method, and the spray method. However, a lower recovery rate (P < 0.05) was obtained for isolation of injured cells on selective media. Overall, these results indicate that the agar spray method is an acceptable alternative to the conventional overlay method and is a simpler and more convenient approach to recovery and detection of injured cells.

  3. Bridging Plate Development for Treatment of Segmental Bone Defects of the Canine Mandible: Mechanical Tests and Finite Element Method.

    PubMed

    de Freitas, Elisângela Perez; Rahal, Sheila Canevese; Shimano, Antonio Carlos; da Silva, Jorge Vicente Lopes; Noritomi, Pedro Yoshito; El-Warrak, Alexander Oliveira; Melchert, Alessandra

    2016-03-01

    With regard to the canine mandible, a mistaken concept of application is to assume that systemic plate-bone resistance is provided by the implant so that biomechanical position could be ignored. Because the alveolar border of the mandible is a tensile zone, the plate would ideally be positioned near this area while avoiding important structures. The aim of this study was to develop 2 bridging plates for the treatment of a segmental bone defect of the canine mandible using monocortical screws to avoid damage to the tooth roots and remaining neurovascular structures. Computed tomography images of the heads of 4 dogs (rottweiler, Doberman, boxer, and miniature poodle breeds) were used as models to develop the project. The images were reconstructed in 3-dimensional (3D) format. For each dog breed, 6 mandible prototypes were produced, each with a segmental bone defect in the right mandible. The mandibular reconstruction was performed with pure titanium bridging plate and locking screws. One plate model was developed for medium- and large-breed dogs and another for small-breed dogs. Mechanical testing showed the platemandible system resists the bite forces in all dog breeds. All safety factors were greater than I in the platemandible system for medium- and large-breed dogs and greater than 10 in the plate-mandible system for small-breed dogs. Thus, bridging plates designed with differentiated geometry and monocortical locking screws showed mechanical resistance to support simulated induced bone model defects and were able to support at least 5 times the value of bite force for each evaluated dog. PMID:27487652

  4. Beyond Agar: Gel Substrates with Improved Optical Clarity and Drug Efficiency and Reduced Autofluorescence for Microbial Growth Experiments.

    PubMed

    Jaeger, Philipp A; McElfresh, Cameron; Wong, Lily R; Ideker, Trey

    2015-08-15

    Agar, a seaweed extract, has been the standard support matrix for microbial experiments for over a century. Recent developments in high-throughput genetic screens have created a need to reevaluate the suitability of agar for use as colony support, as modern robotic printing systems now routinely spot thousands of colonies within the area of a single microtiter plate. Identifying optimal biophysical, biochemical, and biological properties of the gel support matrix in these extreme experimental conditions is instrumental to achieving the best possible reproducibility and sensitivity. Here we systematically evaluate a range of gelling agents by using the yeast Saccharomyces cerevisiae as a model microbe. We find that carrageenan and Phytagel have superior optical clarity and reduced autofluorescence, crucial for high-resolution imaging and fluorescent reporter screens. Nutrient choice and use of refined Noble agar or pure agarose reduce the effective dose of numerous selective drugs by >50%, potentially enabling large cost savings in genetic screens. Using thousands of mutant yeast strains to compare colony growth between substrates, we found no evidence of significant growth or nutrient biases between gel substrates, indicating that researchers could freely pick and choose the optimal gel for their respective application and experimental condition.

  5. Beyond Agar: Gel Substrates with Improved Optical Clarity and Drug Efficiency and Reduced Autofluorescence for Microbial Growth Experiments

    PubMed Central

    Jaeger, Philipp A.; McElfresh, Cameron; Wong, Lily R.

    2015-01-01

    Agar, a seaweed extract, has been the standard support matrix for microbial experiments for over a century. Recent developments in high-throughput genetic screens have created a need to reevaluate the suitability of agar for use as colony support, as modern robotic printing systems now routinely spot thousands of colonies within the area of a single microtiter plate. Identifying optimal biophysical, biochemical, and biological properties of the gel support matrix in these extreme experimental conditions is instrumental to achieving the best possible reproducibility and sensitivity. Here we systematically evaluate a range of gelling agents by using the yeast Saccharomyces cerevisiae as a model microbe. We find that carrageenan and Phytagel have superior optical clarity and reduced autofluorescence, crucial for high-resolution imaging and fluorescent reporter screens. Nutrient choice and use of refined Noble agar or pure agarose reduce the effective dose of numerous selective drugs by >50%, potentially enabling large cost savings in genetic screens. Using thousands of mutant yeast strains to compare colony growth between substrates, we found no evidence of significant growth or nutrient biases between gel substrates, indicating that researchers could freely pick and choose the optimal gel for their respective application and experimental condition. PMID:26070672

  6. Plane elasto-plastic analysis of v-notched plate under bending by boundary integral equation method. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Rzasnicki, W.

    1973-01-01

    A method of solution is presented, which, when applied to the elasto-plastic analysis of plates having a v-notch on one edge and subjected to pure bending, will produce stress and strain fields in much greater detail than presently available. Application of the boundary integral equation method results in two coupled Fredholm-type integral equations, subject to prescribed boundary conditions. These equations are replaced by a system of simultaneous algebraic equations and solved by a successive approximation method employing Prandtl-Reuss incremental plasticity relations. The method is first applied to number of elasto-static problems and the results compared with available solutions. Good agreement is obtained in all cases. The elasto-plastic analysis provides detailed stress and strain distributions for several cases of plates with various notch angles and notch depths. A strain hardening material is assumed and both plane strain and plane stress conditions are considered.

  7. Mupirocin-mucin agar for selective enumeration of Bifidobacterium bifidum.

    PubMed

    Pechar, Radko; Rada, Vojtech; Parafati, Lucia; Musilova, Sarka; Bunesova, Vera; Vlkova, Eva; Killer, Jiri; Mrazek, Jakub; Kmet, Vladimir; Svejstil, Roman

    2014-11-17

    Bifidobacterium bifidum is a bacterial species exclusively found in the human intestinal tract. This species is becoming increasingly popular as a probiotic organism added to lyophilized products. In this study, porcine mucin was used as the sole carbon source for the selective enumeration of B. bifidum in probiotic food additives. Thirty-six bifidobacterial strains were cultivated in broth with mucin. Only 13 strains of B. bifidum utilized the mucin to produce acids. B. bifidum was selectively enumerated in eight probiotic food supplements using agar (MM agar) containing mupirocin (100 mg/L) and mucin (20 g/L) as the sole carbon source. MM agar was fully selective if the B. bifidum species was presented together with Bifidobacterium animalis subsp. lactis, Bifidobacterium breve, and Bifidobacterium longum subsp. longum species and with lactic acid bacteria (lactobacilli, streptococci). Isolated strains of B. bifidum were identified using biochemical, PCR, MALDI-TOF procedures and 16S rRNA gene sequencing. The novel selective medium was also suitable for the isolation of B. bifidum strains from human fecal samples.

  8. Modeling development of inhibition zones in an agar diffusion bioassay

    PubMed Central

    Chandrasekar, Vaishnavi; Knabel, Stephen J; Anantheswaran, Ramaswamy C

    2015-01-01

    A two-temperature agar diffusion bioassay is commonly used to quantify the concentration of nisin using Micrococcus luteus as the indicator microorganism. A finite element computational model based on Fick's second law of diffusion was used to predict the radius of the inhibition zone in this diffusion bioassay. The model developed was used to calculate nisin concentration profiles as a function of time and position within the agar. The minimum inhibitory concentration (MIC) of nisin against M. luteus was determined experimentally. The critical time (Tc) for growth of M. luteus within the agar diffusion bioassay was experimentally determined using incubation studies with nisin. The radius of the inhibition zone was predicted from the computational model as the location where the predicted nisin concentration at Tc was equal to MIC. The MIC was experimentally determined to be 0.156 μg mL−1, and Tc was determined to be 7 h. Good agreement (R2 = 0.984) was obtained between model-predicted and experimentally determined inhibition zone radii. PMID:26405525

  9. Mupirocin-mucin agar for selective enumeration of Bifidobacterium bifidum.

    PubMed

    Pechar, Radko; Rada, Vojtech; Parafati, Lucia; Musilova, Sarka; Bunesova, Vera; Vlkova, Eva; Killer, Jiri; Mrazek, Jakub; Kmet, Vladimir; Svejstil, Roman

    2014-11-17

    Bifidobacterium bifidum is a bacterial species exclusively found in the human intestinal tract. This species is becoming increasingly popular as a probiotic organism added to lyophilized products. In this study, porcine mucin was used as the sole carbon source for the selective enumeration of B. bifidum in probiotic food additives. Thirty-six bifidobacterial strains were cultivated in broth with mucin. Only 13 strains of B. bifidum utilized the mucin to produce acids. B. bifidum was selectively enumerated in eight probiotic food supplements using agar (MM agar) containing mupirocin (100 mg/L) and mucin (20 g/L) as the sole carbon source. MM agar was fully selective if the B. bifidum species was presented together with Bifidobacterium animalis subsp. lactis, Bifidobacterium breve, and Bifidobacterium longum subsp. longum species and with lactic acid bacteria (lactobacilli, streptococci). Isolated strains of B. bifidum were identified using biochemical, PCR, MALDI-TOF procedures and 16S rRNA gene sequencing. The novel selective medium was also suitable for the isolation of B. bifidum strains from human fecal samples. PMID:25217723

  10. Modeling development of inhibition zones in an agar diffusion bioassay.

    PubMed

    Chandrasekar, Vaishnavi; Knabel, Stephen J; Anantheswaran, Ramaswamy C

    2015-09-01

    A two-temperature agar diffusion bioassay is commonly used to quantify the concentration of nisin using Micrococcus luteus as the indicator microorganism. A finite element computational model based on Fick's second law of diffusion was used to predict the radius of the inhibition zone in this diffusion bioassay. The model developed was used to calculate nisin concentration profiles as a function of time and position within the agar. The minimum inhibitory concentration (MIC) of nisin against M. luteus was determined experimentally. The critical time (T c) for growth of M. luteus within the agar diffusion bioassay was experimentally determined using incubation studies with nisin. The radius of the inhibition zone was predicted from the computational model as the location where the predicted nisin concentration at T c was equal to MIC. The MIC was experimentally determined to be 0.156 μg mL(-1), and T c was determined to be 7 h. Good agreement (R (2) = 0.984) was obtained between model-predicted and experimentally determined inhibition zone radii.

  11. Impaction onto a Glass Slide or Agar versus Impingement into a Liquid for the Collection and Recovery of Airborne Microorganisms

    PubMed Central

    Juozaitis, Arvydas; Willeke, Klaus; Grinshpun, Sergey A.; Donnelly, Jean

    1994-01-01

    To study impaction versus impingement for the collection and recovery of viable airborne microorganisms, three new bioaerosol samplers have been designed and built. They differ from each other by the medium onto which the bioaerosol particles are collected (glass, agar, and liquid) but have the same inlet and collection geometries and the same sampling flow rate. The bioaerosol concentrations recorded by three different collection techniques have been compared with each other: impaction onto a glass slide, impaction onto an agar medium, and impingement into a liquid. It was found that the particle collection efficiency of agar slide impaction depends on the concentration of agar in the collection medium and on the sampling time, when samples are collected on a nonmoving agar slide. Impingement into a liquid showed anomalous behavior with respect to the sampling flow rate. Optimal sampling conditions in which all three new samplers exhibit the same overall sampling efficiency for nonbiological particles have been established. Inlet and collection efficiencies of about 100% have been achieved for all three devices at a sampling flow rate of 10 liters/min. The new agar slide impactor and the new impinger were then used to study the biological factors affecting the overall sampling efficiency. Laboratory experiments on the total recovery of a typical environmental microorganism, Pseudomonas fluorescens ATCC 13525, showed that both sampling methods, impaction and impingement, provided essentially the same total recovery when relatively nonstressed microorganisms were sampled under optimal sampling conditions. Comparison tests of the newly developed bioaerosol samplers with those commercially available showed that the incorporation of our research findings into the design of the new samplers yields better performance data than data from currently available samplers. PMID:16349217

  12. A selective chromogenic agar that distinguishes Bacillus anthracis from Bacillus cereus and Bacillus thuringiensis.

    PubMed

    Juergensmeyer, Margaret A; Gingras, Bruce A; Restaino, Lawrence; Frampton, Elon W

    2006-08-01

    A selective and differential plating medium, R & F anthracis chromogenic agar (ACA), has been developed for isolating and identifying presumptive colonies of Bacillus anthracis. ACA contains the chromogenic substrate 5-bromo-4-chloro-3-indoxyl-choline phosphate that upon hydrolysis yields teal (blue green) colonies indicating the presence of phosphatidylcholine-specific phospholipase C (PC-PLC) activity. Among seven Bacillus species tested on ACA, only members of the Bacillus cereus group (B. anthracis, B. cereus, and B. thuringiensis) produced teal colonies (PC-PLC positive) having cream rings. Examination of colony morphology in 18 pure culture strains of B. anthracis (15 ATCC strains plus AMES-1-RIID, ANR-1, and AMED-RIID), with one exception, required 48 h at 35 to 37 degrees C for significant color production, whereas only 24 h was required for B. cereus and B. thuringiensis. This differential rate of PC-PLC synthesis in B. anthracis (due to the truncated plcR gene and PlcR regulator in B. anthracis) allowed for the rapid differentiation on ACA of presumptive colonies of B. anthracis from B. cereus and B. thuringiensis in both pure and mixed cultures. Effective recovery of B. anthracis from a variety of matrices having both high (soil and sewage) and low microbial backgrounds (cloth, paper, and blood) spiked with B. anthracis ANR-1 spores suggests the probable utility of ACA plating for B. anthracis recovery in a diversity of applications.

  13. Comparison of CHROMagar Salmonella Medium and Hektoen Enteric Agar for Isolation of Salmonellae from Stool Samples

    PubMed Central

    Gaillot, Olivier; Di Camillo, Patrick; Berche, Patrick; Courcol, René; Savage, Colette

    1999-01-01

    CHROMagar Salmonella (CAS), a new chromogenic medium, was retrospectively compared to Hektoen enteric agar (HEA) with 501 Salmonella stock isolates and was then prospectively compared to HEA for the detection and presumptive identification of Salmonella spp. with 508 stool samples before and after enrichment. All stock cultures (100%), including cultures of H2S-negative isolates, yielded typical mauve colonies on CAS, while 497 (99%) isolates produced typical lactose-negative, black-centered colonies on HEA. Following overnight incubation at 37°C, a total of 20 Salmonella strains were isolated from the 508 clinical samples. Sensitivities for primary plating and after enrichment were 95% (19 isolates) and 100% (20 isolates), respectively, for CAS and 80% (16 isolates) and 100% (20 isolates), respectively, for HEA. The specificity of CAS (88.9%) was significantly higher than that of HEA (78.5%; P < 0.0001). On the basis of its good sensitivity and specificity, CAS medium can be recommended for use for primary plating when human stool samples are screened for Salmonella spp. PMID:9986847

  14. Comparison of the compact dry TC and 3M petrifilm ACP dry sheet media methods with the spiral plate method for the examination of randomly selected foods for obtaining aerobic colony counts.

    PubMed

    Ellis, P; Meldrum, R

    2002-02-01

    Two hundred thirty-six randomly selected food and milk samples were examined to obtain aerobic colony counts by two dry sheet media methods and a standard Public Health Laboratory Service spiral plate method. Results for 40 samples were outside the limits of detection for one or more of the tested methods and were not considered. (The limits of detection for the spiral plate method were 200 to 1 x 10(8) CFU/ml for the spiral plate method and 100 to 3 x 10(6) CFU/ml for the dry sheet media methods.) The remaining 196 sets of results were analyzed further. When the results from the three methods were compared, correlation coefficients were all >0.80 and slopes and intercepts were close to 1.0 and 0.0, respectively. Mean log values and standard deviations were very similar for all three methods. The results were evaluated according to published UK guidelines for ready-to-eat foods sampled at the point of sale, which include a quality acceptability assessment that is based on aerobic colony counts. Eighty-six percent of the comparable results gave the same verdict with regard to acceptability according to the aerobic colony count guidelines. Both dry sheet media methods were comparable to the spiral plate method and can be recommended for the examination of food.

  15. End plate assembly having a two-phase fluid-filled bladder and method for compressing a fuel cell stack

    DOEpatents

    Carlstrom, Jr., Charles M.

    2001-01-01

    An end plate assembly is disclosed for use in a fuel cell assembly in which the end plate assembly includes a housing having a cavity, and a bladder receivable in the cavity and engageable with the fuel cell stack. The bladder includes a two-phase fluid having a liquid portion and a vapor portion. Desirably, the two-phase fluid has a vapor pressure between about 100 psi and about 600 psi at a temperature between about 70 degrees C. to about 110 degrees C.

  16. Lohse's historic plate archive

    NASA Astrophysics Data System (ADS)

    Tsvetkov, M.; Tsvetkova, K.; Richter, G.; Scholz, G.; Böhm, P.

    The description and the analysis of Oswald Lohse's astrophotographic plates, collected at the Astrophysical Observatory Potsdam in the period 1879 - 1889, are presented. 67 plates of the archive, taken with the greatest instrument of the observatory at that time - the refractor (D = 0.30 m, F = 5.40 m, scale = 38''/mm) and with the second heliographic objective (D = 0.13 m, F = 1.36 m, scale = 152''/mm) - - survived two world wars in relative good condition. The plate emulsions are from different manufacturers in the beginning of astrophotography (Gädicke, Schleussner, Beernaert, etc.). The sizes of the plates are usually 9x12 cm2, which corresponds to fields of 1.2deg and 5deg respectively for each instrument mentioned above. The average limiting magnitude is 13.0(pg). Besides of the plates received for technical experiments (work on photographic processes, testing of new instruments and methods of observations), the scientific observations follow programs for studies of planet surfaces, bright stars, some double stars, stellar clusters and nebulous objects. Lohse's archive is included into the Wide Field Plate Database (http://www.skyarchive.org) as the oldest systematic one, covering the fields of Orion (M42/43), Pleiades, h & chi Persei, M37, M3, M11, M13, M92, M31, etc. With the PDS 2020 GM+ microdensitometer of Münster University 10 archive plates were digitized.

  17. Combined Use of Pastorex Staph-Plus and Either of Two New Chromogenic Agars, MRSA ID and CHROMagar MRSA, for Detection of Methicillin-Resistant Staphylococcus aureus▿

    PubMed Central

    Compernolle, Veerle; Verschraegen, Gerda; Claeys, Geert

    2007-01-01

    We describe the search toward a fast and reliable strategy to detect and confirm the presence of methicillin-resistant Staphylococcus aureus (MRSA) in screening samples. First, we evaluated the sensitivities and specificities of oxacillin resistance screening agar (ORSA) with enrichment (tryptic soy broth [TSB] and ORSA [TSB-ORSA]) and without enrichment (ORSA), MRSA ID (MRSA_ID) plates, and CHROMagar MRSA (C_MRSA) plates, all of which were inoculated with equal volumes of a suspension made by emulsifying screening swabs. Whereas the sensitivities after 48 h were similar for all media tested (77% for MRSA_ID and ORSA; 73% for C_MRSA and ORSA after enrichment [TSB-ORSA]), the specificities of MRSA_ID (98% after 24 h and 94% after 48 h) and C_MRSA (98% after 24 h and 90% after 48 h) were superior to the specificities of ORSAs (92% after 24 h and 83% after 48 h) and TSB-ORSA (86% after 24 h and 81% after 48 h). Subsequently, the performance of the Pastorex Staph-Plus agglutination test with presumptive MRSA isolates taken directly from chromogenic agars (direct_Pastorex agglutination) was compared to that of the Pastorex Staph-Plus agglutination test with isolates from blood agar subcultures (conventional_Pastorex agglutination). When the direct_Pastorex agglutination test on MRSA_ID plates was combined with Gram staining, the direct_Pastorex agglutination test with samples from MRSA_ID plates was as reliable as the conventional_Pastorex agglutination test with samples from blood agar subcultures from MRSA_ID plates. In contrast, the direct_Pastorex agglutination test with samples from C_MRSA plates gave false-negative results. Finally, we calculated the processing times of the four different strategies, namely, (i) enrichment in TSB supplemented with NaCl, subsequent culture on ORSA, and the conventional_Pastorex agglutination test; (ii) direct inoculation of ORSA combined with conventional_Pastorex agglutination test; (iii) direct inoculation of MRSA_ID plates

  18. Equivalent modulus method for finite element simulation of the sound absorption of anechoic coating backed with orthogonally rib-stiffened plate

    NASA Astrophysics Data System (ADS)

    Jin, Zhongkun; Yin, Yao; Liu, Bilong

    2016-03-01

    The finite element method is often used to investigate the sound absorption of anechoic coating backed with orthogonally rib-stiffened plate. Since the anechoic coating contains cavities, the number of grid nodes of a periodic unit cell is usually large. An equivalent modulus method is proposed to reduce the large amount of nodes by calculating an equivalent homogeneous layer. Applications of this method in several models show that the method can well predict the sound absorption coefficient of such structure in a wide frequency range. Based on the simulation results, the sound absorption performance of such structure and the influences of different backings on the first absorption peak are also discussed.

  19. Improved Method for Detection of Vibrio parahaemolyticus in Seafood

    PubMed Central

    Hara-Kudo, Yukiko; Nishina, Tokuhiro; Nakagawa, Hiroshi; Konuma, Hirotaka; Hasegawa, Junko; Kumagai, Susumu

    2001-01-01

    We have developed a new, effective procedure for detecting Vibrio parahaemolyticus in seafoods using enrichment and plating onto a chromogenic agar medium. Samples were cultured in salt Trypticase soy broth, which is a nonselective medium, and then a portion of the culture was cultured with salt polymyxin broth, which is a selective medium for V. parahaemolyticus. This two-step enrichment was more effective than the one-step enrichment in salt polymyxin broth alone. The enrichment cultures were then plated onto a new chromogenic agar containing substrates for beta-galactosidase. The V. parahaemolyticus colonies developed a purple color on this growth medium that distinguished them from other related bacterial strains. V. parahaemolyticus was isolated more frequently from naturally contaminated seafood samples using the chromogenic agar than thiosulfate citrate bile salts sucrose agar medium, which is currently used for the isolation of V. parahaemolyticus. Our findings suggest that this new enrichment and isolation scheme is more sensitive and accurate for identifying V. parahaemolyticus in seafood samples than previously used methods. PMID:11722939

  20. Improved method for detection of Vibrio parahaemolyticus in seafood.

    PubMed

    Hara-Kudo, Y; Nishina, T; Nakagawa, H; Konuma, H; Hasegawa, J; Kumagai, S

    2001-12-01

    We have developed a new, effective procedure for detecting Vibrio parahaemolyticus in seafoods using enrichment and plating onto a chromogenic agar medium. Samples were cultured in salt Trypticase soy broth, which is a nonselective medium, and then a portion of the culture was cultured with salt polymyxin broth, which is a selective medium for V. parahaemolyticus. This two-step enrichment was more effective than the one-step enrichment in salt polymyxin broth alone. The enrichment cultures were then plated onto a new chromogenic agar containing substrates for beta-galactosidase. The V. parahaemolyticus colonies developed a purple color on this growth medium that distinguished them from other related bacterial strains. V. parahaemolyticus was isolated more frequently from naturally contaminated seafood samples using the chromogenic agar than thiosulfate citrate bile salts sucrose agar medium, which is currently used for the isolation of V. parahaemolyticus. Our findings suggest that this new enrichment and isolation scheme is more sensitive and accurate for identifying V. parahaemolyticus in seafood samples than previously used methods.