Science.gov

Sample records for agglutination test specific

  1. Latex agglutination test

    MedlinePlus

    ... the results of this test. Normal Results Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider ...

  2. Bayesian estimation of sensitivity and specificity of the modified agglutination test and bioassay for detection of Toxoplasma gondii in free-range chickens

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Toxoplasma gondii infects virtually all warm-blooded animals worldwide. Serological tests, including the modified agglutination test (MAT), are often used to determine exposure to the parasite. The MAT can be used for all hosts because it does not need species-specific reagents and has been shown to...

  3. Latex agglutination using the periplasmic proteins antigen of Brucella melitensis is a successful, rapid, and specific serodiagnostic test for ovine brucellosis.

    PubMed

    Ismael, Alaa Bassuny; Swelum, Ayman Abdel-Aziz; Mostafa, Salama A-H; Alhumiany, Abdel-Rahman A

    2016-09-01

    Brucellosis, especially caused by Brucella melitensis, is considered the most-widespread zoonosis in the world, particularly in developing countries. This study was planned to develop an accurate test for diagnosis of ovine brucellosis using a specific hot saline extracted soluble Brucella melitensis periplasmic proteins (SBPPs). The efficacy of the latex agglutination test (LAT) using SBPPs compared to the Rose Bengal test (RBT), buffered plate agglutination test (BPAT), serum agglutination test (SAT), and an indirect enzyme-linked immunosorbent assay (i-ELISA) was evaluated in the field diagnosis of ovine brucellosis. The test performance was evaluated by estimating sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), disease prevalence (DP), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) using test agreement and bacteriological culture in 1777 samples. The false-positive result was significantly (P ⩽0.05) lower in LAT than RBT, BPAT, SAT, and i-ELISA. With reference to test agreement, the Se, Sp, PPV, and PLR were highest (P ⩽0.05) in LAT 99.33%, 99.88%, 98.68%, and 827.25%, respectively. With reference to bacteriological culture, the LAT and i-ELISA tests showed a significant difference in Se with SAT. However, no significant difference in specificity was detected. The DP was 8.44% in the five tests. In conclusion, LAT using SBPPs of B. melitensis could be a suitable serodiagnostic field test for ovine brucellosis, with high sensitivity and specificity.

  4. Rapid Detection of Contagious Caprine Pleuropneumonia Using a Mycoplasma capricolum subsp. capripneumoniae Capsular Polysaccharide-Specific Antigen Detection Latex Agglutination Test

    PubMed Central

    March, J. B.; Gammack, C.; Nicholas, R.

    2000-01-01

    Latex microspheres (diameter, 8 μm) were coated with anti-Mycoplasma capricolum subsp. capripneumoniae polyclonal immunoglobulin G (IgG) antiserum (anti-F38 biotype). The coated microspheres, when used in a latex agglutination test (LAT), detected M. capricolum subsp. capripneumoniae antigen in the serum of goats with contagious caprine pleuropneumoniae (CCPP). Beads also agglutinated strongly in the presence of purified M. capricolum subsp. capripneumoniae capsular polysaccharide (CPS). Preabsorption of CPS-specific antibodies prior to coating of the beads removed agglutinating activity in the presence of M. capricolum subsp. capripneumoniae, strongly suggesting that CPS is the likely soluble antigen recognized by the test. In addition, the specificity of the LAT exactly mirrored that of an M. capricolum subsp. capripneumoniae CPS-specific monoclonal antibody (WM25): of the 8 other mycoplasma species tested, agglutination was observed only with bovine serogroup 7. The LAT detected all 11 strains of M. capricolum subsp. capripneumoniae examined in this study, with a sensitivity level of 2 ng of CPS, or the equivalent of 1.7 × 104 CFU, in a reaction volume of 0.03 ml of serum. With field sera from goats with CCPP, the results of the LAT exhibited a 67% correlation with the results of the currently used complement fixation test (CFT), with the main discrepancy in diagnosis resulting from the increased sensitivity of the LAT compared to that of CFT. This antigen-detection LAT should prove particularly useful in identifying animals in the earliest stages of CCPP and combines sensitivity and low cost with ease of application in the field, without the need for any specialist training or equipment. PMID:11060083

  5. Stable suspension for Vi-agglutination tests

    PubMed Central

    Ando, Koji; Shimojo, Hiroto

    1953-01-01

    Two methods of preparing a stable suspension for Vi-agglutination tests are discussed. Both maintain Vi-agglutinability and O-inagglutinability after storage at 37°C for 6 months, and the second also maintains the Vi-capsule-staining property. The first method involves the addition of 0.5% CaCl2 to a heavy saline Vi-suspension, while in the second a similar suspension is treated with an 0.2% solution of chrome alum. PMID:20603972

  6. Direct agglutination test for serologic diagnosis of Neospora caninum infection.

    PubMed

    Romand, S; Thulliez, P; Dubey, J P

    1998-01-01

    A direct agglutination test was evaluated for the detection and quantitation of IgG antibodies to Neospora caninum in both experimental and natural infections in various animal species. As compared with results obtained by the indirect fluorescent antibody test, the direct agglutination test appeared reliable for the serologic diagnosis of neosporosis in a variety of animal species. The direct agglutination test should provide easily available and inexpensive tools for serologic testing for antibodies to N. caninum in many host species.

  7. Latex agglutination: diagnose the early cryptococcus neoformans test of capsular polysaccharide antigen.

    PubMed

    Wang, Huanrong; Yuan, Xueqian; Zhang, Lifeng

    2015-01-01

    This paper aims to discuss the early diagnosis value of latex agglutination test in Cryptococcal meningitis. The cerebrospinal fluid (CSF) of 112 patients with definite Cryptococcal meningitis and 26 patients with tubercular meningitis and virus meningitis were collected, latex agglutination test is adopted to detect Cryptococcal capsular polysaccharide antigen. Then it was compared with fungal culture and direct microscopy method for evaluating the sensitivity and specificity of the diagnosis. The sensitivity of three methods including latex agglutination test, fungal culture and direct microscopy was 91.1%,69.6% and 73.2% respectively. The specificity of latex agglutination test was 96.0%, 100% and 100% respectively. That latex agglutination test to detect Cryptococcal capsular polysaccharide antigen could be taken as the early diagnostic method of Cryptococcus neoformans meningitis.

  8. Latex agglutination test (LAT) for the diagnosis of typhoid fever.

    PubMed

    Sahni, Gopal Shankar

    2013-06-01

    The efficacy of latex agglutination test in the rapid diagnosis of typhoid fever was studied and the result compared with that of blood culture. This study included 80 children suffering from typhoid fever, among which 40 were confirmed by blood culture isolation and 40 had possible typhoid fever based on high Widal's titre (a four-fold rise in the titre of antibody to typhi "O" and "H" antigen was considered as a positive Widal's test result). Eighty children, 40 with febrile illness confirmed to be other than typhoid and 40 normal healthy children were used as negative controls. The various groups were: (i) Study group ie, group I had 40 children confirmed by culture isolation of Salmonella typhi(confirmed typhoid cases). (ii) Control groups ie, (a) group II with 40 febrile controls selected from paediatrics ward where cause other than S typhi has been established, (b) group III with 40 afebrile healthy controls that were siblings of the children admitted in paediatric ward for any reason with no history of fever and TAB vaccination in the last one year, and (c) group IV with 40 children with high Widal's titre in paired sera sample. Widal's test with paired sera with a one week interval between collections were done in all 40 patients. Latex aggtutination test which could detect 900 ng/ml of antigen as observed in checker board titration, was positive in all 40 children from group I who had positive blood culture and in 30 children from group IV who had culture negative and had high Widal's titre positive. Latex agglutination test was positive in 4 children in group II and none in group III. Using blood culture positive cases as true positive and children in groups II and III as true negative, the test had a sensitivity of 100% and specificity of 96%. Latex agglutination test was found to be significantly sensitive (100%) and specific (96%) and could detect 75% more cases in group IV (possible typhoid cases). Thus latex agglutination test can be used for rapid

  9. Improving agglutination tests by working in microfluidic channels.

    PubMed

    Degré, G; Brunet, E; Dodge, A; Tabeling, P

    2005-06-01

    Latex agglutination tests are used for the diagnosis of diseases in man and animals. They are generally simple, cheap, and do not require sophisticated equipment, nor highly specialized skills. In this Technical Note, we put latex agglutination tests in a microfluidic format. The experiment is performed in PDMS (polydimethylsiloxane) microchannels, using streptavidin-coated superparamagnetic beads and a magnetic field. The target molecule is biotinylated protein A. By taking full advantage of the microfluidic conditions (scaling down of the detection volume and controlled action of the shear flow), we achieved an analytical sensitivity of 10 fmol l(-1)(several hundreds of fg ml(-1)) and a fast response (a few minutes) ; the test is also quantitative. Performances of agglutination tests can thus be improved by orders of magnitude by adapting them to a microfluidic format; this comes in addition to the usual advantages offered by this technology (integration, high throughput etc.).

  10. Bayesian estimation of true prevalence, sensitivity and specificity of indirect ELISA, Rose Bengal Test and Slow Agglutination Test for the diagnosis of brucellosis in sheep and goats in Bangladesh.

    PubMed

    Rahman, A K M Anisur; Saegerman, Claude; Berkvens, Dirk; Fretin, David; Gani, Md Osman; Ershaduzzaman, Md; Ahmed, Muzahed Uddin; Emmanuel, Abatih

    2013-06-01

    The true prevalence of brucellosis and diagnostic test characteristics of three conditionally dependent serological tests were estimated using the Bayesian approach in goats and sheep populations of Bangladesh. Serum samples from a random selection of 636 goats and 1044 sheep were tested in parallel by indirect ELISA (iELISA), Rose Bengal Test (RBT) and Slow Agglutination Test (SAT). The true prevalence of brucellosis in goats and sheep were estimated as 1% (95% credibility interval (CrI): 0.7-1.8) and 1.2% (95% CrI: 0.6-2.2) respectively. The sensitivity of iELISA was 92.9% in goats and 92.0% in sheep with corresponding specificities of 96.5% and 99.5% respectively. The sensitivity and specificity estimates of RBT were 80.2% and 99.6% in goats and 82.8% and 98.3% in sheep. The sensitivity and specificity of SAT were 57.1% and 99.3% in goats and 72.0% and 98.6% in sheep. In this study, three conditionally dependent serological tests for the diagnosis of small ruminant brucellosis in Bangladesh were validated. Considerable conditional dependence between IELISA and RBT and between RBT and SAT was observed among sheep. The influence of the priors on the model fit and estimated parameter values was checked using sensitivity analysis. In multiple test validation, conditional dependence should not be ignored when the tests are in fact conditionally dependent.

  11. Macroscopic Agglutination Test for Rapid Diagnosis of Human Leptospirosis

    PubMed Central

    Brandão, Angela P.; Camargo, Eide D.; da Silva, Emilson D.; Silva, Marcos V.; Abrão, Rui V.

    1998-01-01

    A commercially available slide agglutination test (SAT) for the diagnosis of human leptospirosis was evaluated by comparing it to an immunoglobulin M (IgM) enzyme-linked immunosorbent assay (ELISA) and to the microscopic agglutination test (MAT). For all 108 patients, leptospirosis was diagnosed on the basis of a fourfold or greater increase in titer by MAT (seroconversion), and all but 1 of 245 controls were MAT negative (titers, <1:100). Both SAT and the IgM ELISA failed to detect one case of infection (sensitivity, 99%). Only 3 of 145 blood donors and none of the 100 patients with other illnesses were SAT positive (specificity, 99%). The overall results were similar for the three tests; however, SAT and ELISA were statistically more sensitive as initial screening tests. For 22% of the patients, the diagnosis of leptospirosis was made earlier by SAT than by MAT. SAT detected 27 (44%) of 62 MAT-negative patients with the first serum sample. ELISA and SAT had very similar results. Follow-up of patients for 1 year after the onset of symptoms showed a decreasing rate of positivity by SAT from the third month on. The rate of positivity by ELISA decreased more slowly, to about 67% by the end of the study. By MAT all patients were persistently reactive. SAT and ELISA seem to be convenient methods for the rapid and early screening for leptospirosis and could replace the less sensitive MAT. ELISA gives less subjective results than SAT and provides information on IgM kinetics, but it can be performed only by the more sophisticated laboratories. SAT is inexpensive, can be performed more quickly and more easily than ELISA, and could be used by the less well equipped laboratories. PMID:9774553

  12. [The pretransfusion bedside agglutination test is not a "Gold Standard"].

    PubMed

    Levy, G

    2008-11-01

    ABO-incompatible transfusions remain frequent in Europe despite the technological progresses in relation with the potential number of human errors during the control procedures of the transfusion chain. The agglutination bedside-test is only one step of this chain and the amelioration of the security will be achieved by its replacement by an electronical check.

  13. Spatial and spatio-temporal clustering of overall and serovar-specific Leptospira microscopic agglutination test (MAT) seropositivity among dogs in the United States from 2000 through 2007.

    PubMed

    Gautam, Raju; Guptill, Lynn F; Wu, Ching Ching; Potter, Adam; Moore, George E

    2010-08-01

    Leptospirosis is a re-emerging disease of dogs in the United States (U.S.). This paper reports the findings of a retrospective study conducted to determine if seroreactivity to Leptospira microscopic agglutination test (MAT) among dogs in the U.S. clustered in space and time. The study utilized canine sera submitted to a commercial laboratory for leptospiral MAT from January 2000 through December 2007. There were 31,869 serum samples submitted by veterinarians from 3156 zip code locations across the U.S. Results of MAT were considered positive at titers of > or = 1:1600. Spatial and spatial-temporal scan statistics were used to identify statistically significant clusters of seroreactivity to Leptospira (overall and individual serovars) using recorded test request dates and locations of the centroid of the zip code reported for each serum sample. There were 2469 positive MAT results with a titer > or = 1:1600 to at least one of seven Leptospira serovars. Two relevant spatial clusters of 26.3 and 246.5 km radius were identified (P=0.001). The primary cluster was located in the northeastern part of Illinois including Chicago and surrounding areas (232 [14.4%] of 1612 MAT positive; RR=1.95). The secondary cluster covered the central part of Texas (292 [12.62%] of 2314 MAT positive; RR=1.71). Eight space-time clusters of overall MAT positivity were identified (29-335 km radius; P=0.001-0.048 and RR=3.98-24.69) that covered different geographic locations for different time points. Spatial and space-time clusters for individual serovars were also identified for six serovars: eight each of Grippotyphosa and Pomona, seven of Bratislava, five of Autumnalis, and three each of Icterohaemorrhagiae and Canicola. In conclusion Leptospira seropositivity in dogs tended to have distinctive clusters in space and space-time. Most of the space-time clusters of overall Leptospira MAT seropositivity were associated with cluster events for individual serovars. Further investigation is

  14. Serogrouping of Bacteroides fragilis subsp. fragilis by the agglutination test.

    PubMed Central

    Lambe, D W; Moroz, D A

    1976-01-01

    The agglutination technique was used to establish a serological classification scheme for 98 strains of Bacteroides fragilis subsp. fragilis isolated from clinical specimens and normal human feces. Absorbed antisera were prepared to seven strains of B. fragilis subsp. fragilis. These seven absorbed antisera were species as well as subspecies specific and provided the basis of the serological classification scheme. This scheme was composed of 21 serogroups; seven of these serogroups contained only one group component. There was a total of 45 serological patterns. This serological scheme may be used for the serological classification of strains of B. fragilis subsp. fragilis and to study the epidemiology of this organism. PMID:950378

  15. A rapid latex agglutination test for detection of leptospiral antibodies.

    PubMed

    Ramadass, P; Samuel, B; Nachimuthu, K

    1999-10-01

    A rapid semi-quantitative latex agglutination test (LAT) has been standardized for the detection of leptospiral antibodies in serum samples of man and animals. The efficacy of the LAT was compared with the plate enzyme linked immunosorbent assay (ELISA). A total of 276 human serum samples were analyzed by both LAT and ELISA and percentage positives were 84.8 and 85.9%, respectively. Similarly, of 65 animal samples tested, 63.1 and 69.2% positivity were observed in LAT and ELISA, respectively. Even though the ELISA test was slightly more sensitive than LAT, the rapidity, simplicity and economics of the LAT were found to fulfill the requirements of a screening test for leptospiral antibodies.

  16. Commercial latex agglutination test for rapid diagnosis of group B streptococcal infection in infants.

    PubMed Central

    Webb, B J; Baker, C J

    1980-01-01

    Although latex agglutination assays for detection of a variety of bacterial antigens in body fluids from patients with systemic infection have been shown to be useful as rapid diagnostic techniques, lack of commercial availability has restricted their application. The Streptex latex test kit for the detection of group B streptococcal (GBS) antigen in admission body fluid specimens was evaluated for sensitivity and specificity in 54 infants with meningitis and in 10 infants with normal cerebrospinal fluid (CSF) parameters. GBS antigen was detected in 22 of 28 (78.6%) CSF specimens by latex agglutination and in 23 of 28 (82.1%) by countercurrent immunoelectrophoresis. Antigen was present in 21 of 28 (latex agglutination) and 19 of 26 (countercurrent immunoelectrophoresis) CSF specimens after the initiation of antimicrobial therapy. Heat-labile factors accounted for nonspecific agglutination reactions with latex suspensions other than group B in 3 of 28 CSF samples from patients with GBS meningitis. These nonspecific reactions were readily eliminated by heating specimens for 10 min at 100 degrees C. Fifteen patients with GBS meningitis had admission serum and urine samples collected in addition to CSF. Antigen was detected by latex agglutination and countercurrent immunoelelectrophoresis in 14 of 15 (93.3%) and 13 of 15 (86.7%) concentrated urine specimens, respectively, and in 12 of 15 (80%) CSF specimens and 4 of 15 (27%) sera by each method. These findings indicate that the Streptex latex test is a rapid, sensitive, and readily available method for detection of GBS antigen in admission body fluid specimens from infants with meningitis. PMID:7012177

  17. 9 CFR 147.1 - The standard tube agglutination test. 1

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false The standard tube agglutination test... Blood Testing Procedures § 147.1 The standard tube agglutination test. 1 1 The procedure described is a... containers provided by the laboratory. The containers should be stout-walled test tubes, preferably 3/8 by...

  18. 9 CFR 147.1 - The standard tube agglutination test. 1

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false The standard tube agglutination test... Blood Testing Procedures § 147.1 The standard tube agglutination test. 1 1 The procedure described is a... containers provided by the laboratory. The containers should be stout-walled test tubes, preferably 3/8 by...

  19. 9 CFR 147.1 - The standard tube agglutination test. 1

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false The standard tube agglutination test... Blood Testing Procedures § 147.1 The standard tube agglutination test. 1 1 The procedure described is a... containers provided by the laboratory. The containers should be stout-walled test tubes, preferably 3/8 by...

  20. Latex agglutination test for detecting feline panleukopenia virus, canine parvovirus, and parvoviruses of fur animals.

    PubMed Central

    Veijalainen, P M; Neuvonen, E; Niskanen, A; Juokslahti, T

    1986-01-01

    A latex agglutination (LA) test for the detection of parvoviruses of fur animals, cats, and dogs was developed, and its sensitivity and specificity were compared with those of hemagglutination (HA) and the enzyme-linked immunosorbent assay (ELISA). Tissue culture isolation was used to confirm the specificity results. Fecal samples from various sources were tested, including specimens from raccoon dogs and mink which were experimentally infected with parvoviruses by oral exposure. LA compared favorably with the other tests. The ELISA was the most sensitive. When it was considered as a reference test, the corresponding sensitivities for HA and LA were 96 and 91%, respectively. The specificities were 93% for the ELISA, 95% for the HA test, and 92% for the LA test. LA seems to be a suitable technique for screening animals in the field and in laboratories in which sophisticated techniques are not available. PMID:3007568

  1. Comparison of genomic and antimicrobial resistance features of latex agglutination test-positive and latex agglutination test-negative Staphylococcus aureus isolates causing bovine mastitis.

    PubMed

    Moser, A; Stephan, R; Corti, S; Johler, S

    2013-01-01

    The dairy industry suffers massive economic losses due to staphylococcal mastitis in cattle. The Staphaureux latex agglutination test (Oxoid, Basel, Switzerland) was reported to lead to negative results in 54% of bovine Staphylococcus aureus strains, and latex-negative strains are thought to be less virulent than Staphaurex latex-positive strains. However, comparative information on virulence and resistance profiles of these 2 groups of Staph. aureus is scarce. Our objective was to associate the latex agglutination phenotype of Staph. aureus strains isolated from bovine mastitis milk with data on clonal complexes, virulence genes, and antibiotic resistance to (1) determine the virulence profiles of the Staphaureux test positive and Staphaurex test negative groups, and (2) provide data needed to improve treatment of bovine mastitis and to identify potential vaccine targets. Seventy-eight Staph. aureus strains isolated from 78 cows on 57 Swiss farms were characterized. Latex agglutination was tested by Staphaureux kit, and resistance profiles were generated by disk diffusion. A DNA microarray was used to assign clonal complexes (CC) and to determine virulence and resistance gene profiles. By the Staphaureux test, 49% of the isolates were latex-positive and 51% were latex-negative. All latex-negative strains were assigned to CC151, whereas latex-positive strains were assigned to various clonal complexes, including CC97 (n=16), CC8 (n=10), CC479 (n=5), CC20 (n=4), CC7 (n=1), CC9 (n=1), and CC45 (n=1). Although the latex-negative isolates were susceptible to all antimicrobial agents tested, 24% of latex-positive isolates were classified as intermediate with regard to cefalexin-kanamycin and 13% were resistant to both ampicillin and penicillin. Microarray profiles of latex-negative isolates were highly similar, but differed largely from those of latex-positive isolates. Although the latex-negative group lacked several enterotoxin genes and sak, it exhibited significantly

  2. Comparison of PCR, Wright agglutination test and blood culture for diagnosis of brucellosis in suspected patients.

    PubMed

    Hekmatimoghaddam, Seyedhosssein; Sadeh, Maryam; Khalili, Mohammad Bagher; Mollaabedin, Mansour; Sazmand, Alireza

    2013-11-15

    Brucellosis has long been prevalent in Iran, with considerable medical and economic importance. Timely diagnosis is needed for early management and effective prevention of its consequences in human beings and animals. Current diagnostic methods impose peculiar challenges in terms of analytical method performance. This study compares diagnostic sensitivity, specificity, predictive Value of Positive (PVP) and Predictive Value of Negative (PVN) for Polymerase Chain Reaction (PCR), Wright agglutination test and blood culture used for patients suspected of brucellosis. In 120 patients clinically suspected of brucellosis and referred by physicians to the Yazd central Medical Laboratory, some relevant demographic, occupational, nutritional and clinical data were collected. Also, venous blood samples were drawn for diagnosis of brucellosis using PCR, Wright agglutination test and blood culture techniques. The most frequent symptom of patients was arthralgia (82 cases, 68.3%). PCR was positive in 25 cases (20.8%), wright test in 21 patients (17.5%) and blood culture in 6 cases (5%). In 20 out of 21 wright-positive cases, PCR was positive and all of the culture-positive patients had positive PCR. Sensitivity, specificity, PVP and PVN of blood culture compared to PCR (as the gold standard test) were 24, 100, 100 and 86%, respectively, but the above parameters when PCR is compared with blood culture (as gold standard) were 100, 83, 24 and 95%, respectively. PCR has better analytical performances than blood culture for diagnosis of brucellosis and is suitable for confirmation of Wright-positive cases.

  3. Evaluation of a commercial latex agglutination test for rapid detection of Salmonella in fecal samples.

    PubMed

    Bänffer, J R; van Zwol-Saarloos, J A; Broere, L J

    1993-08-01

    A latex agglutination test for the detection of salmonella in feces was evaluated in comparison to direct culture and enriched culture using both artificially inoculated samples and clinical samples. In the samples inoculated artificially with different concentrations of salmonella (10(1) to 10(5) per gram) the enriched culture performed better only at the 10(2) level in 0.4 g samples, whereas the latex test performed as well as the enriched culture at all levels in 4 g samples. In the tests using clinical samples, there was no significant difference between results of the latex test performed in 2283 samples and the enriched culture performed in 2072 samples. The sensitivity, specificity and negative and positive predictive values of the latex test were 88.2%, 98%, 97.5% and 63% respectively. The test provided results rapidly but yielded a number of false positive results.

  4. Evaluation of the one-point microcapsule agglutination test for diagnosis of leptospirosis.

    PubMed Central

    Arimitsu, Y.; Kmety, E.; Ananyina, Y.; Baranton, G.; Ferguson, I. R.; Smythe, L.; Terpstra, W. J.

    1994-01-01

    We have developed a one-point microcapsule agglutination test (MCAT) for the serodiagnosis of leptospirosis. The MCAT kit was evaluated for use in humans by six WHO Collaborating Centres for Reference and Research on Leptospirosis. The laboratories classified their serum samples on the basis of the microscopic agglutination test (MAT) and the following screening tests: enzyme-linked immunosorbent assay (ELISA), macroscopic (slide) agglutination test, or the complement fixation test. The MCAT may in some instances give a positive result earlier in the course of the disease than MAT or the ELISA IgM; on the other hand, it did not detect antibodies against some serovars, for example, those of the Sejroe or Australis serogroup in Slovakia. In contrast, however, the MCAT detected antibodies to serovar hardjo (the same serogroup as Sejroe) in patients from the United Kingdom and the Russian Federation. PMID:8062397

  5. Usefulness of PCR and Antigen Latex Agglutination Test with Samples Obtained by Transthoracic Needle Aspiration for Diagnosis of Pneumococcal Pneumonia

    PubMed Central

    García, Amparo; Rosón, Beatriz; Pérez, José Luis; Verdaguer, Ricard; Dorca, Jordi; Carratalà, Jordi; Casanova, Aurora; Manresa, Frederic; Gudiol, Francesc

    1999-01-01

    In a large number of cases, the etiology of community-acquired pneumonia (CAP) is not established. Some cases are probably caused by Streptococcus pneumoniae. Transthoracic needle aspiration (TNA) culture has a limited sensitivity which might be improved by antigen detection or gene amplification techniques. We evaluated the capacity of a PCR assay and a latex agglutination test to detect S. pneumoniae in samples obtained by TNA from 95 patients with moderate-to-severe CAP. Latex agglutination and PCR had sensitivities of 52.2 and 91.3%, specificities of 88.7 and 83.3%, positive predictive values of 62.3 and 65.6%, and negative predictive values of 83.3 and 96.5%, respectively, when culture techniques were used as the “gold standard.” When we considered expanded criteria for the diagnosis of pneumococcal pneumonia as a standard for our calculations, latex agglutination and PCR had sensitivities of 53.6 and 89.7%, specificities of 93.0 and 90.0%, positive predictive values of 78.9 and 81.3%, and negative predictive values of 80.3 and 94.7%, respectively. The additional diagnosis provided by the PCR assay compared to latex agglutination was 12.2% (95% confidence interval of the difference from 0.4 to 20.1%). PCR was more sensitive than TNA culture, particularly in patients who had received prior antibiotic therapy (83.3 versus 33.3%). Although PCR is a very sensitive and specific technique, it has not proved to be cost-effective in clinical practice. Conversely, latex agglutination is a fast and simple method whose results might have significant implications for initial antibiotic therapy. PMID:9986837

  6. Alpha mating type-specific expression of mutations leading to constitutive agglutinability in Saccharomyces cerevisiae.

    PubMed Central

    Doi, S; Yoshimura, M

    1985-01-01

    Two mutants of Saccharomyces cerevisiae have been isolated and characterized. The mutants were constitutively agglutinable at 36 degrees C, the temperature at which wild-type cells agglutinate only after induction by mating pheromone. The mutant cells had other properties specific for the normal alpha cell type, i.e., conjugation with a cells, response to a mating pheromone, and production of alpha mating pheromone. The two mutations, cag1 and cag2, were recessive and expressed only in alpha cells. cag1 is linked very closely to the MAT locus, but cag2 is unlinked to the MAT locus. These cag mutations complemented ste3-1. These results indicate that CAG genes are novel alpha-specific genes involved in the regulation of sex agglutinin synthesis. PMID:3881403

  7. Human African trypanosomiasis: a latex agglutination field test for quantifying IgM in cerebrospinal fluid.

    PubMed Central

    Lejon, V.; Büscher, P.; Sema, N. H.; Magnus, E.; Van Meirvenne, N.

    1998-01-01

    LATEX/IgM, a rapid agglutination test for the semi-quantitative detection of IgM in cerebrospinal fluid of patients with African trypanosomiasis, is described in this article. The lyophilized reagent has been designed for field use and remains stable at 45 degrees C for one year. The test has been evaluated on cerebrospinal fluid samples from trypanosome-infected and non-infected patients, by comparison with commercial latex agglutination, radial immunodiffusion, and nephelometry. All test systems yielded similar results. PMID:10191550

  8. Blood stained cerebrospinal fluid responsible for false positive reactions of latex particle agglutination tests.

    PubMed Central

    Camargos, P A; Almeida, M S; Filho, G L; Batista, K W; Carvalho, A G; Pereira, C L

    1994-01-01

    The accuracy of the latex particle agglutination test (LPAT) was assessed in blood stained cerebrospinal fluid (CSF) specimens from 166 paediatric patients, aged from three months to 13 years. A commercial LPAT kit was used to detect Haemophilus influenzae type b, Streptococcus pneumoniae, and Neisseria meningitidis A, B, and C soluble antigens. Culture of CSF specimens was used as the standard and all laboratory procedures were performed blind. The mean CSF erythrocyte count was 66,406 cells/mm3 in the cases and 11,560 cells/mm3 in the controls. The sensitivity and the specificity of LPAT were 83.8 and 94.0%, respectively, suggesting that LPAT is a useful diagnostic tool even in blood stained CSF specimens. PMID:7876387

  9. Cross-reactivity in Cryptococcus antigen latex agglutination test in two commercial kits.

    PubMed

    Tone, Kazuya; Umeda, Yoshiko; Makimura, Koichi

    2016-05-01

    This article presents an examination of the cross-reactivity of pathogenic fungi with Cryptococcus neoformans in two commercial Cryptococcus antigen latex agglutination tests performed across 39 fungal strains. Some fungi were newly indicated as Cryptococcus cross-reactive, and the two kits showed differences in cross-reactive fungi.

  10. Evaluation of Pyloriset Dry, a new rapid agglutination test for Helicobacter pylori antibody detection.

    PubMed Central

    Lozniewski, A; De Korwin, J D; Conroy, M C; Plenat, F; Weber, M

    1996-01-01

    We evaluated the performance of a new latex agglutination test, Pyloriset Dry (Orion Diagnostica, Espoo, Finland), in the simultaneous detection of immunoglobulin G (IgG), IgA, and IgM antibodies to Helicobacter pylori and compared it with that of the Pyloristat test (BioWhittaker, Fontenay-sous-Bois, France), an enzyme-linked immunosorbent assay detecting IgG to H. pylori, for 96 untreated dyspeptic patients who had undergone gastroduodenal endoscopy. Infection was diagnosed in 56 cases by positive culture and/or positive Giemsa stain and rapid urease test (antral biopsies) and was associated with chronic gastritis in 52 patients. Forty noninfected patients did not have chronic gastritis. The sensitivity of Pyloriset Dry was 91.1%. The sensitivity of Pyloristat was 91.1 or 82.1%, depending on whether equivocal results were considered positive or negative, respectively. Both tests had a specificity of 87.5%. Their performances were not statistically different. Thus, Pyloriset Dry is an alternative to serological tests for adults, particularly when a small number of serum samples has to be tested. PMID:8784587

  11. Characterization of two different agglutinators in the latex fixation test, occurring in normal human sera

    PubMed Central

    Klein, F.; Valkenburg, H. A.; Van Zwet, Theda L.; Lafeber, Geertruida J. M.

    1966-01-01

    Using a sensitive modification of the latex fixation test it is possible to detect a small agglutinating effect in about 60 per cent of normal human sera, after these have been heated for 30 minutes at 56°. This was shown to be caused by an IgM globulin with the properties of a rheumatoid factor. The factor is able to react with human IgG globulin and may represent an antibody to the IgG part of circulating antigen—antibody complexes. The heat treatment probably inactivates an inhibitor of the latex fixation reaction. In addition all normal human sera give an agglutination reaction with IgG coated latex at incubation temperatures of 37° or lower. It was shown that these reactions are caused by a thermolabile, non-reducible component with a sedimentation constant of about 10. This component is probably identical with the complement component C'1q. The agglutinating activity was found in the α2—β1 region after electrophoresis of untreated serum, but in the slow γ region after treatment of the serum with EDTA. This kind of agglutination may cause false positive reactions in latex tests which are carried out at 37° or less. ImagesFIG. 1FIG. 3 PMID:4160336

  12. Rapid detection of methicillin-resistant Staphylococcus aureus strains not identified by slide agglutination tests.

    PubMed Central

    Kuusela, P; Hildén, P; Savolainen, K; Vuento, M; Lyytikäinen, O; Vuopio-Varkila, J

    1994-01-01

    Seventy-nine methicillin-resistant Staphylococcus aureus (MRSA) strains, isolated during 1980 to 1990, were classified as MRSA Aggl- (14 strains) and MRSA Aggl+ (65 strains) strains on the basis of test results in slide agglutination assays designed to detect fibrinogen-binding protein (clumping factor) and protein A on the staphylococcal surface. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis analysis revealed that lysostaphin digests of MRSA Aggl- strains contained a high-molecular-weight protein which was not detected in digests of MRSA Aggl+ strains. Immunization of rabbits with an MRSA Aggl- strain produced an antiserum which agglutinated all MRSA Aggl- strains and also 64 of 65 MRSA Aggl+ strains. Only 1 of 68 coagulase-negative staphylococci showed agglutination in this assay. The anti-MRSA Aggl- antiserum reacted mainly with a 230-kDa staphylococcal surface protein but also with a 175-kDa protein, probably formed by proteolysis of the former and a few slightly smaller proteins. These could not be immunologically detected in lysostaphin digests of MRSA Aggl+ strains. Purified antibodies reacting with the 230-kDa protein agglutinated all MRSA Aggl- strains, indicating that the protein is located on the surfaces of staphylococci. The results suggest a tentative role for the 230-kDa protein or its fragments as a novel target to develop more efficient rapid identification methods for S. aureus, including MRSA. Images PMID:8126170

  13. Elemental X-ray mapping of agglutinated foraminifer tests: a non- destructive technique for determining compositional characteristics.

    USGS Publications Warehouse

    Commeau, R.F.; Reynolds, Leslie A.; Poag, C.W.

    1985-01-01

    The composition of agglutinated foraminiferal tests vary remarkably in response to local substrate characteristics, physiochemical properties of the water column and species- dependant selectivity of test components. We have employed a technique that combines a scanning electron microscope with an energy dispersive X-ray spectrometer system to identify major and minor elemental constituents of agglutinated foraminiferal walls. As a sample is bombarded with a beam of high energy electrons, X-rays are generated that are characteristic of the elements present. As a result, X- ray density maps can be produced for each of several elements present in the tests of agglutinated foraminifers. -Authors

  14. [Evaluation of the usefulness of the agglutination test with Mangifera indica extract for the identification of pathogenic Yersinia enterocolitica strains].

    PubMed

    Kałuzewski, S; Gierczyński, R; Szych, J; Jagielski, M

    1997-01-01

    The study was performed on 137 Y. enterocolitica strains belonging to various serological groups, including 75 03 group strains isolated form human clinical material. The agglutination test on slides was carried out on this strains using Mangifera indica extract of own production. Agglutinating preparation obtained from the seeds of M. indica agglutinated Y. enterocolitica organisms possessing the pVY plasmid and CRMOX+ phenotype in dilutions to 1.56 micrograms/ml. In identification tests conducted parallelly agglutination solution was used in concentrations of 100 and 10 micrograms/ml. All clones of Y. enterocolitica from O3 group from cultures at 37 degrees C and with CRMOX+ phenotype possessing the pVY plasmid were agglutinated by the extract. Agglutination failed to develop in the cultures of these clones incubated at 25 degrees C. Yersinia clones not containing the pVY plasmid with CRMOX- phenotype were resistant to agglutination. The virulence plasmid was found in 44 out of 75 strains of Y. enterocolitica O3 and was identified by restriction analysis after plasmid DNA digestion with Eco RI enzyme. The obtained results agreed with those of Wauters et al. in 1995 and confirmed the opinion of these authors on the usefulness of the test with M. indica agglutinin for the identification of virulent Y. enterocolitica strains.

  15. [The evaluation of different agglutination and adhesion tests with erythrocytic reagents in determining antibodies to the O and H antigens of Salmonella typhimurium in comparison with immunoenzyme analysis (IEA)].

    PubMed

    Karal'nik, B V; Denisova, T G

    1996-01-01

    The comparison of the effectiveness of EIA with that of a number of agglutination and adhesion tests with erythrocyte diagnostica in the determination of antibodies to different S.typhimurium antigens demonstrated higher sensitivity of EIA. The relative specificity of the determination of O- and H-antibodies in EIA and in agglutination and adhesion tests depended on the isotype of antibodies to be determined and the specificity of sensitins used in the production of immunoreagents.

  16. Rapid detection of infectious mononucleosis-associated heterophile antibodies by a novel immunochromatographic assay and a latex agglutination test.

    PubMed Central

    Farhat, S E; Finn, S; Chua, R; Smith, B; Simor, A E; George, P; Diena, B B; Diena, D; Skulnick, M

    1993-01-01

    A novel immunochromatographic assay, the CARDS O.S. MONO test (Pacific Biotech, San Diego, Calif.), and a latex agglutination test, the Infectious Mononucleosis Kit (Unipath Ltd., Hampshire, United Kingdom) were compared with the Paul-Bunnell-Davidsohn test. Of the 957 serum specimens studied, 78 were positive and 879 were negative by the Paul-Bunnell-Davidsohn test. After discrepancies were resolved by determining Epstein-Barr virus serology, the sensitivities of the CARDS O.S. MONO test and the Infectious Mononucleosis Kit were 91.0 and 96.2%, respectively, and both tests had a specificity and a positive predictive value of 100% and a negative predictive value and overall agreement of greater than 99%. The results show that both tests can accurately detect infectious mononucleosis-associated heterophile antibodies. PMID:8315001

  17. A prototype of the direct agglutination test kit (DAT-Canis) for the serological diagnosis of canine visceral leishmaniasis.

    PubMed

    Oliveira, Edward; Saliba, Juliana Wilke; Oliveira, Diana; Dias, Edelberto Santos; Paz, Gustavo Fontes

    2016-05-15

    This report describes the stege I/II development of a new direct agglutination test (DAT) for the diagnosis of canine visceral leishmaniasis (CVL) using freeze-dried antigen produced Coomassie blue-stained Leishmania (Leishmania) infantum promastigotes. In stage I, 16 canine serum samples, collected from eight dogs carrying CVL and eight healthy dogs, were assessed with the DAT using 2-mercaptoethanol (2-ME), N-acetyl-cysteine (NAC), kaolin or NAC plus urea (NAC+U) to improve the assay conditions. Stage II assessed the diagnostic accuracy with 100 serum samples collected from dogs with symptomatic CVL and clinically healthy dogs, comparing the four different sample diluents. The CVL-DAT prototype kit showed equivalent performances when 2-ME, NAC or NAC+U were used: 97.1% sensitivity (CI: 83-99.8%), 97% specificity (CI: 88.5-99.5%) and a 97% diagnostic accuracy (CI: 90.8-99.2). With kaolin, a 94.1% sensitivity (CI: 79-99%), 97% specificity (CI: 88.5-99.5%) and 96% diagnostic accuracy were observed (CI: 89.5-98.7), with no statistically significant differences among the four reagents (p=1.0). The NAC plus urea in sample diluent decreased non-specific agglutination, promoted a better defined sharp-edged blue spot and was thus chosen as a component for the new DAT prototype to diagnose canine VL, designated DAT-Canis.

  18. Agglutination of Helicobacter pylori coccoids by lectins

    PubMed Central

    Khin, Mar Mar; Hua, Jie Song; Ng, Han Cong; Wadström, Torkel; Ho, Bow

    2000-01-01

    AIM: To study the agglutination pattern of Helicobacter pylori coccoid and spiral forms. METHODS: Assays of agglutination and agglutination inhibition were applied using fifteen commercial lectins. RESULTS: Strong agglutination was observed with mannose-specific Concanavalin A (Con A), fucose-specific Tetragonolobus purpureas (Lotus A) and N-acetyl glucosamine-specific Triticum vulgaris (WGA) lectins. Mannose and fucose specific lectins were reactive with all strains of H. pylori coccoids as compared to the spirals. Specific carbohydrates, glycoproteins and mucin were shown to inhibit H. pylori lectin-agglutination reactions. Pre-treatment of the bacterial cells with formalin and sulphuric acid did not alter the agglutination patterns with lectins. However, sodium periodate treatment of bacterial cells were shown to inhibit agglutination reaction with Con A, Lotus A and WGA lectins. On the contrary, enzymatic treatment of coccoids and spirals did not show marked inhibition of H. pylori lectin agglutination. Interes tingly, heating of H. pylori cells at 60 °C for 1 h was shown to augment the agglutination with all of the lectins tested. CONCLUSION: The considerable differences in lectin agglutination patterns seen among the two differentiated forms of H. pylori might be attributable to the structural changes during the events of morphological transformation, resulting in exposing or masking some of the sugar residues on the cell surface. Possibility of various sugar residues on the cell wall of the coccoids may allow them to bind to different carbohydrate receptors on gastric mucus and epithelial cells. The coccoids with adherence characteristics like the spirals could aid in the pathogenic process of Helicobacter infection. This may probably lead to different clinical outcome of H. pylori associated gastroduodenal disease. PMID:11819557

  19. Evaluation of the MycoAKT latex agglutination test for rapid diagnosis of Mycobacterium avium complex infections.

    PubMed

    Olano, J P; Holmes, H; Woods, G L

    1998-01-01

    Rapid diagnosis of Mycobacterium avium complex (MAC) bacteremia is important for management of patients with the acquired immunodeficiency syndrome who have disseminated MAC. The purpose of this study was to determine the reliability of the MycoAKT latex agglutination test for direct detection of MAC in positive mycobacterial blood cultures. First, colonies of isolates of previously identified mycobacteria, including 35 MAC, were tested. Of the 55 isolates evaluated, 33 were identified as MAC by the latex test, including 31 of the known MAC and 2 M. chelonae (sensitivity, 88.6%; specificity, 90.0%). Second, broth from 20 ESP II and 20 BACTEC 12B bottles seeded with isolates of MAC were tested. Aliquots from 19 (95%) ESP II cultures and 16 (80%) 12B cultures were positive by the latex test. In phase 3, broth from 115 signal-positive ESP II blood cultures were tested by latex agglutination. Forty-three subcultures from these bottles grew mycobacteria (41 MAC and 2 Mycobacterium tuberculosis complex); the remainder grew no organisms. Broth from 40 of the blood cultures (39 that grew MAC and 1 from which no organisms were recovered) were latex positive; thus, the sensitivity, specificity, and positive and negative predictive values of the latex test for direct identification of MAC in ESP II blood cultures were 95.1, 98.6, 97.5, and 97.3%, respectively. The mean time to detection of MAC was 14.6 days (range, 6-34 days) with the direct latex test, compared with 18.3 days (range, 9-36 days) with subculture and probe (p < 0.05).

  20. Case report: false negative serum cryptococcal latex agglutination test in a patient with disseminated cryptococcal disease.

    PubMed

    Navabi, Nazlee; Montebatsi, Milton; Scott, Michelle; Gluckman, Stephen J; Reid, Michael J A

    2015-01-01

    A case of false-negative serum latex agglutination cryptococcal antigen (CRAG) test in a 45-year-old HIV-positive male with Cryptococcus-positive culture is described. The patient was presented to a hospital in Botswana, with breathlessness and a diffuse papular rash. His CD4 count was 25 cells/μL. Despite the suspicion for disseminated cryptococcal disease, an initial serum CRAG latex test was negative. Results of subsequent Indian ink staining, culture of cerebrospinal fluid and skin scrapings, and serum lateral flow immunoassay (LFA) were all positive for Cryptococcus neoformans. There are several possible explanations for the false-negative CRAG latex test. Given the positive LFA result, we speculate that disease may have been caused by Cryptococcus gattii, which is estimated to be responsible for between 15% and 30% of all cryptococcal diseases in Botswana. Reduced sensitivity of CRAG latex assays for detecting C gattii may lead to underdiagnosis of cryptococcal infection.

  1. Preliminary observations on the use of latex agglutination test for the detection of mastitis due to Streptococcus agalactiae in cows.

    PubMed Central

    Daniel, R C; Barnum, D A

    1986-01-01

    A commercial latex agglutination test for the detection of Group B streptococcal antigens was used to detect infection due to Streptococcus agalactiae in whey of bovine milk samples. Fifteen out of 17 known infections were detected, but it was necessary to incubate the wheys at 37 degrees C for 18 hours in nine of the samples. It was found that the latex agglutination test could detect Group streptococcal carbohydrate antigens in whey samples from artificially infected quarters from one to four days after failure to detect the organism on culture or after antibiotic therapy of the affected quarter. PMID:3527389

  2. The relationship of the lunar regolith less than 10-microns fraction and agglutinates. II - Chemical composition of agglutinate glass as a test of the 'fusion of the finest fraction' /F3/ model

    NASA Technical Reports Server (NTRS)

    Walker, R. J.; Papike, J. J.

    1982-01-01

    Agglutinate glasses from nine Apollo soils have been studied using an automated electron microprobe technique in order to test the fusion of the finest fraction model proposed by Papike (1981). The nine average agglutinate glass compositions are compared with the calculated fused-soil-free compositions, the bulk compositions and the 90-20 micron fraction compositions of the soils in which they are found. It is found that the agglutinate glass data are consistent with the composition of most of the fractions finer than 10 microns, allowing for the volatile loss of K2O and Na2O; some inconsistencies that do arise may result from the degree of soil maturity and the amount of material finer than 10 microns. It is concluded that the fusion of the finest fraction model is a good first approximation of mechanisms affecting the formation of agglutinate glass.

  3. Rapid latex particle agglutination test for Escherichia coli strains of porcine origin producing heat-labile enterotoxin.

    PubMed Central

    Finkelstein, R A; Yang, Z S; Moseley, S L; Moon, H W

    1983-01-01

    A latex particle agglutination test previously shown to be suitable for the rapid identification of Escherichia coli strains of human origin producing heat-labile enterotoxin (R. A. Finkelstein and Z. Yang, J. Clin. Microbiol. 18:23-28) is equally applicable to strains of porcine origin. PMID:6361056

  4. The latex agglutination test versus counterimmunoelectrophoresis for rapid diagnosis of bacterial meningitis

    PubMed Central

    Bortolussi, Robert; Wort, Arthur J.; Casey, Stephanie

    1982-01-01

    A modified latex agglutination (LA) test was compared with Gram-staining and counterimmunoelectrophoresis (CIE) for the rapid detection in the cerebrospinal fluid (CSF) of antigen to Haemophilus influenzae type b, Neisseria meningitidis groups A, B and C, Escherichia coli K1, Streptococcus pneumoniae and group B streptococci, seven frequent causes of bacterial meningitis in children. Of 50 CSF samples from patients with culture-proven bacterial meningitis 90% were correctly shown by the LA test to contain antigen of the responsible organism. Gram-staining revealed organisms in 80% of 45 of these samples. In 75% of the 40 samples that were of sufficient volume for CIE, positive results for the appropriate antigen were obtained. The concentration of antigen detected in the CSF by the LA test varied from undetectable to 800 000 ng/ml. Patients with a high concentration (more than 2000 ng/ml or a positive result at dilutions of CSF over 1/8) were significantly more likely to have a poor response to therapy (two died and two had persistent pleocytosis or bacteria in the CSF) than patients with a lower concentration (4/16 v. 0/18, P < 0.05). After appropriate therapy was begun the concentration of antigen fell dramatically, but measurable amounts of antigen persisted in the CSF for up to 6 days. The LA test detected bacterial antigen at concentrations 2 to 70 times below the lower limit detected by CIE. In seven additional patients who had received antibiotics before lumbar puncture was performed the LA test detected antigen from meningitis-causing bacteria even though cultures of the CSF were sterile. In another 145 patients who did not have meningitis the results of the LA test were negative. The LA test, done as described in this article, is easier to perform than CIE and should be a useful addition to the diagnostic tests carried out on the CSF of any patient suspected of having meningitis. PMID:6749272

  5. A systematic review on the microscopic agglutination test seroepidemiology of bovine leptospirosis in Latin America.

    PubMed

    Pinto, Priscila da Silva; Libonati, Hugo; Penna, Bruno; Lilenbaum, Walter

    2016-02-01

    The diagnosis of leptospirosis commonly relies on serology, which has three issues that are referred: the sampling, the antigen panel, and the cutoff point. We propose a systematic review of the bovine leptospirosis in Latin America, in order to provide a better understanding of the evolution of the research and of the seroepidemiology of bovine leptospirosis in that region. Internet databases were consulted over the year of 2014. Inclusion criteria for analysis included serosurvey using microscopic agglutination test (MAT), a relevant number of animals, the presence in the antigen panel of at least one representant of serogroup Sejroe, and a cutoff point of ≥100. A total of 242 articles that referred to cattle, leptospir*, and one region of Latin America was found. Only 105 articles regarding to serosurveys using MAT were found in several countries, and 61 (58.1 %) met all the inclusion criteria. In conclusion, this systematic review demonstrated a high prevalence of the infection (75.0 % at herd level and 44.2 % at animal level), with predominance of strains of serogroup Sejroe (80.3 %). It was evident that there is the necessity of more studies in several countries, as well as the need for greater standardization in studies, especially with regard to the adopted cutoff point at serological tests.

  6. Validation studies of the latex agglutination test for the detection of Trichinella larvae in meat products.

    PubMed

    Gayda, Jennifer; Reckinger, Sabine; Thaben, Nora; Nöckler, Karsten; Mayer-Scholl, Anne

    2016-11-15

    Human trichinellosis is a foodborne disease caused by ingestion of meat infected with Trichinella muscle larvae. To control Trichinella spp. infection in the European Union, all slaughtered pigs from holdings that are not officially recognized as applying controlled housing conditions and other animals susceptible to Trichinella infection and intended for human consumption should be examined by one of the approved digestion methods described in Regulation (EU) No. 2015/1375. In the past, Trichinella outbreaks due to the consumption of cured wild boar or pork products have been described in several European countries, making the identification of the larvae from these products relevant for Trichinella control. Therefore, this study aimed to validate the newly approved latex agglutination test (Trichin-L) for routine testing of cured meat products. The test was validated based on the OIE Guidelines using pork products spiked with Trichinella larvae. The sensitivity of the method varied greatly depending on the investigated meat product and was usually lower than for the gold standard, the magnetic stirrer method. The detection rate reached 80% for three larvae and 60% for one larva in cured pork sausages. A detection rate of 100% for three larvae and 50% for one larva was found in bacon. For frozen samples (-20°C) the Trichin-L kit is similarly sensitive as for cured samples. Further, to determine the performance of the test under field conditions, pork products from regions with known high Trichinella prevalences confiscated by customs authorities at two German international airports were analyzed. Problems associated with the Trichin-L test were incomplete digestion due to fatty ingredients, spices and very dry meat products, resulting in data which could not be evaluated. Therefore, the test is currently not suitable for the detection of Trichinella larvae in cured meat products and needs further adaptation steps to increase both usability and sensitivity.

  7. Quantitative capillary reversed passive latex agglutination test for C-reactive protein (CRP) in the dog.

    PubMed

    Tagata, K; Yokoyama, S; Ginbo, T; Honda, M; Okimura, T; Odakura, M; Nomura, M; Yamamoto, S

    1996-01-01

    A capillary reversed passive latex agglutination test (capillary RPLA) was developed which allows quantification of serum C-reactive protein (CRP) within approximately 15 min. The logarithmic regression line (calibration curve) obtained after measuring each CRP concentration three times in twofold dilutions of a standard canine serum containing 222 micrograms/ml of CRP was y = 6.394 + 0.030x (r = 0.995). Capillary RPLA permitted quantification of CRP in the range 6.9-222 micrograms/ml. The coefficients of variation ranged from 10.28% to 12.40%. The recovery rates (percentage recovery) of CRP by capillary RPLA were within the range 87% to 106%. On measuring the CRP concentrations in sera from 78 dogs by capillary RPLA, single radial immunodiffusion (SRID) and enzyme-linked immunosorbent assay (ELISA), close correlations were demonstrated between SRID and capillary RPLA (y = 7.250 + 1.109x, r = 0.978), between SRID and ELISA (y = 3.042 + 1.059x, r = 0.967), and between capillary RPLA and ELISA (y = 1.778 + 0.929x, r = 0.962). Capillary RPLA may be considered useful as a routine biochemical technique for measurement of serum CRP concentration in the dog.

  8. [Relationship between the sensitivity of the delayed agglutination test and synthetic detergents].

    PubMed

    Iovchev, E; Vodas, K

    1977-01-01

    Residual amounts of detergents (Losk, Bio-73, Alka-lux, Bourgas, Bourgaslux, and Vero) in a concentration of 10-5 to 10-7 in physiologic saline can inhibit the agglutination titers by 3 to 5 degrees. This could mislead in the assessment of the reaction with regard to its diagnostic value. It is admitted that the inhibition produced is due to changes in the antibodies--drop in the total protein and light variations in all protein fractions as well as in the probable surface deterioration of the antigen, leading to its defective agglutinability. It is suggested to rinse more than five times all glassware that has been cleaned with detergents.

  9. A comparison of titers of anti-Brucella antibodies of naturally infected and healthy vaccinated cattle by standard tube agglutination test, microtiter plate agglutination test, indirect hemagglutination assay, and indirect enzyme-linked immunosorbent assay

    PubMed Central

    Mohan, Anju; Saxena, Hari Mohan; Malhotra, Puneet

    2016-01-01

    Aim: We determined the antibody response in cattle naturally infected with brucellosis and normal healthy adult cattle vaccinated during calf hood with strain 19. Materials and Methods: The antibody titers were measured by standard tube agglutination test (STAT), microtiter plate agglutination test (MAT), indirect hemagglutination assay (IHA), and indirect enzyme-linked immunosorbent assay (iELISA) as per standard protocols. Results: The mean STAT titers were 1.963±0.345 in infected cattle and 1.200±0.155 in healthy vaccinated cattle. The difference was extremely significant (p<0.0001). The mean MAT titers were 2.244±0.727 in infected cattle and 1.200±0.155 in healthy vaccinated cattle. The difference was very significant (p<0.005). The mean IHA titers in infected cattle were 2.284±0.574, and those in healthy vaccinated cattle were 1.200±0.155. The difference was extremely significant (p=0.0002). However, the difference in mean iELISA titers of infected cattle (1.3678±0.014) and healthy vaccinated cattle (1.367±0.014) was non-significant. The infected animals showed very high titers of agglutinating antibodies compared to the vaccinated animals. However, it cannot be ascertained whether these antibodies are due to vaccine or response to infection. Since the infected animals had been vaccinated earlier, the current infection may suggest that vaccination was unable to induce protective levels of antibody. The heightened antibody response after infection may also indicate a secondary immune response to the antigens common to the vaccine strain and wild Brucella organisms. Conclusion: The brucellosis infected animals showed very high titers of agglutinating antibodies compared to the vaccinated animals. PMID:27536032

  10. 9 CFR 147.1 - The standard tube agglutination test. 1

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., high agglutinability, but are not sensitive to negative and nonspecific sera. The stock cultures may be... hours at 37 °C. The antigenic composition and purity of the stock cultures should be checked... cultures prepared from the stock cultures of the selected strains. The antigen-growing tubes or...

  11. 9 CFR 147.1 - The standard tube agglutination test. 1

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., high agglutinability, but are not sensitive to negative and nonspecific sera. The stock cultures may be... hours at 37 °C. The antigenic composition and purity of the stock cultures should be checked... cultures prepared from the stock cultures of the selected strains. The antigen-growing tubes or...

  12. Comparison of the H7 latex agglutination test with a fliCh7 real-time PCR assay for confirmation of the H type of Escherichia coli O157:H7

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Escherichia coli O157:H7 is a food-borne pathogen that causes hemorrhagic colitis and hemolytic uremic syndrome. Positive identification of E. coli O157:H7 is made using biochemical tests and latex agglutination using specific antisera. However, under certain conditions, some E. coli O157:H7 isolate...

  13. Collaborative evaluation of antigen detection by a commercial latex agglutination test and enzyme immunoassay in the diagnosis of invasive candidiasis.

    PubMed Central

    Lemieux, C; St-Germain, G; Vincelette, J; Kaufman, L; de Repentigny, L

    1990-01-01

    The Cand-Tec Candida detection system and enzyme immunoassay for serum mannan were retrospectively compared in a controlled collaborative evaluation of antigen detection in 32 patients with candidiasis proven by biopsy or culture from a normally sterile site and with sera drawn within 7 days of inclusion. With a threshold titer of 1/8, which excluded false-positive results in 17 hospitalized patients without candidiasis, sensitivities for all 32 patients with candidiasis were 44% for the Cand-Tec assay and 17% for the enzyme immunoassay. Both assays provided greater sensitivity when sera were drawn within 24 h of inclusion in the study and in the category of patients with invasive candidiasis (57% by Cand-Tec and 33% by enzyme immunoassay). The Cand-Tec assay gave false-positive results (titer, greater than or equal to 1/8) in 4 of 6 patients with transient candidemia, in 1 of 20 otherwise healthy patients with rheumatoid factor, and in 1 patient with a positive cryptococcal latex agglutination test. Three serum specimens from 3 of 32 patients with candidiasis contained rheumatoid factor and gave titers of greater than or equal to 1/8 by the Cand-Tec assay. Detection of serum mannan by enzyme immunoassay was less sensitive but more specific than the Cand-Tec Candida detection system for the diagnosis of invasive candidiasis. PMID:2179258

  14. Evaluation of a C-reactive protein latex agglutination detection test with sera from patients with sexually transmitted diseases.

    PubMed Central

    Schalla, W O; Arko, R J; Thompson, S E

    1984-01-01

    A total of 149 sera, including 79 pre- and posttreatment sera from 33 patients with disseminated gonococcal infections, 18 from patients with uncomplicated gonococcal infections, 6 from patients with pelvic inflammatory disease, 4 from patients with genital Chlamydia trachomatis infections, and 42 from normal volunteers, were examined for C-reactive protein with a latex agglutination C-reactive protein detection kit (Difco Laboratories, Detroit, Mich.). Results were quantitated with LC-Partigen C-reactive protein radial immuno-diffusion plates (Calbiochem-Behring, La Jolla, Calif.). Positive latex agglutination results were observed in all of the pretreatment sera and some of the posttreatment sera of patients with disseminated gonococcal infections and in two sera from patients with pelvic inflammatory disease, which corresponded to quantitative C-reactive protein levels in the radial immunodiffusion plates. C-reactive protein levels were not detectable in the serum samples from normal volunteers or patients with uncomplicated gonococcal infections or genital chlamydial infections. Positive latex agglutination occurred as early as 20 s in sera with high C-reactive protein levels, and all positive results were observed within 90 s of the 3-min test limit. Positive latex test results were obtained with C-reactive protein levels as low as 1 mg/dl (10 micrograms/ml). PMID:6440907

  15. Comparative assessment of the leprosy antibody absorption test, Mycobacterium leprae extract enzyme-linked immunosorbent assay, and gelatin particle agglutination test for serodiagnosis of lepromatous leprosy.

    PubMed Central

    Escobar-Gutiérrez, A; Amezcua, M E; Pastén, S; Pallares, F; Cázares, J V; Pulido, R M; Flores, O; Castro, E; Rodríguez, O

    1993-01-01

    A comparative assessment of three serological methods for leprosy diagnosis (the fluorescent leprosy antibody absorption [FLA-ABS] test, the Mycobacterium leprae soluble-extract enzyme-linked immunosorbent assay [ELISA], and the M. leprae particle agglutination [MLPA] test) was carried out. The objective was to identify their performance in clinical and epidemiological diagnosis of leprosy. The study group included 45 lepromatous leprosy patients under treatment. Specificity was > 95% for all three assays, and sensitivity was 95, 58, and 74% for the FLA-ABS test, the MLPA test, and the ELISA, respectively. The only cross-reactivity for M. tuberculosis-infected patients was with the soluble-extract ELISA. Although the FLA-ABS test displayed the highest specificity and sensitivity values, it can only be used in well-developed laboratories, and the patient's clinical and epidemiological background must be considered when results are interpreted because the test remains positive after therapeutic success and could be positive for some household contacts. The MLPA test is easier to perform and interpret, and it is adequate for small laboratories and epidemiological studies intended to detect active untreated or irregularly treated leprosy cases. Therefore, the FLA-ABS and MLPA tests are complementary, and both should be used for serodiagnosis of leprosy. PMID:8501238

  16. Rapid detection of human group C rotaviruses by reverse passive hemagglutination and latex agglutination tests using monoclonal antibodies.

    PubMed Central

    Kuzuya, M; Fujii, R; Hamano, M; Nagabayashi, T; Tsunemitsu, H; Yamada, M; Nii, S; Mori, T

    1993-01-01

    Reverse passive hemagglutination (RPHA) tests and a latex agglutination test with monoclonal antibodies (MAbs) were developed for the rapid detection of noncultivatable human group C rotaviruses. For RPHA tests, two MAbs, MAb 5A12 recognizing the outer capsid and MAb 13A3 recognizing the inner capsid, were separately used for the coating of sheep erythrocytes (SRBCs). Forty-six fecal samples were examined to confirm the practicality of the tests. As a result, there was concordance between the RPHA test with SRBCs coated with MAb 5A12 and polyacrylamide gel electrophoresis of viral RNA (RNA-PAGE) in 44 (95.6%) of 46 samples, while the diagnoses by the RPHA test with SRBCs coated with MAb 13A3 were in complete agreement with those by RNA-PAGE. Furthermore, a latex agglutination test with MAb 13A3 was also developed, and this test was fast enough and sensitive enough to successfully detect the viruses from most fecal samples within 2 min. The present procedures would be useful for the diagnosis of human group C rotavirus infections in clinical laboratories which are not well equipped. Images PMID:8388891

  17. Development and assessment of a latex agglutination test based on recombinant MSP5 to detect antibodies against Anaplasma marginale in cattle

    PubMed Central

    Ramos, Carlos A.N.; Araújo, Flábio R.; Santos, Rafaelle C.; Melo, Elaine S.P.; Sousa, Letícia C.; Vidal, Carlos E.S.; Guerra, Neurisvan R.; Ramos, Rafael A.N.

    2014-01-01

    The recombinant protein MSP5 has been established as an important antigen for serological diagnosis of Anaplasma marginale by enzyme-linked immunosorbent assay (ELISA). However, due to the high cost of specialized equipment, this technique is not accessible to all laboratories, especially in developing countries in areas where the disease is endemic. The present study describes the standardization of a latex agglutination test (LAT) to detect antibodies against A. marginale based on recombinant MSP5. Compared with indirect enzyme-linked immunosorbent assay (iELISA), the relative sensitivity and specificity of the LAT were 95.21% and 91.86% respectively, with an almost perfect agreement between tests (kappa index = 0.863). These results can be considered important for the serological diagnosis of A. marginale, as they indicate that the test represents a rapid and low cost alternative to ELISA. PMID:24948931

  18. Development and assessment of a latex agglutination test based on recombinant MSP5 to detect antibodies against Anaplasma marginale in cattle.

    PubMed

    Ramos, Carlos A N; Araújo, Flábio R; Santos, Rafaelle C; Melo, Elaine S P; Sousa, Letícia C; Vidal, Carlos E S; Guerra, Neurisvan R; Ramos, Rafael A N

    2014-01-01

    The recombinant protein MSP5 has been established as an important antigen for serological diagnosis of Anaplasma marginale by enzyme-linked immunosorbent assay (ELISA). However, due to the high cost of specialized equipment, this technique is not accessible to all laboratories, especially in developing countries in areas where the disease is endemic. The present study describes the standardization of a latex agglutination test (LAT) to detect antibodies against A. marginale based on recombinant MSP5. Compared with indirect enzyme-linked immunosorbent assay (iELISA), the relative sensitivity and specificity of the LAT were 95.21% and 91.86% respectively, with an almost perfect agreement between tests (kappa index = 0.863). These results can be considered important for the serological diagnosis of A. marginale, as they indicate that the test represents a rapid and low cost alternative to ELISA.

  19. Comparison of indirect fluorescent antibody test and the modified agglutination test for the detection of Toxoplasma gondii antibodies in stray dogs from Southern Brazil.

    PubMed

    de Almeida, Jonatas Campos; Frehse, Michelle Salmon; Navarro, Italmar Teodorico; Garcia, João Luis; Biondo, Alexander Welker; Freire, Roberta Lemos

    2016-12-01

    The aim of the present study was to determine the prevalence of antibodies to Toxoplasma gondii by two serological techniques in sera of 364 stray dogs from Brazil by immunofluorescence antibody test (IFAT, cut off point 1:16) and to the modified agglutination test (MAT, cut-off points 1:25 and 1:50). A total of 175/364 (48.07%) sera were positive by IFAT, and 108/364 (29.67%) and 85/364 (23.35%) were positive by MAT with cutoff points 1:25 and 1:50, respectively were positive by MAT. Cohen's Kappa Coefficient between IFAT and MAT was 0.81 (excellent) and 0.66 (substantial) with cutoff points 1:25 and 1:50, respectively. Using IFAT as gold standard, MAT sensitivity and specificity were 78% and 99% for 1:25 and 61% and 99% for 1:50, respectively. The results document of the usefulness of MAT for serological diagnosis because it does not require species-specific conjugate.

  20. Reverse-Transcriptase PCR Detection of Leptospira: Absence of Agreement with Single-Specimen Microscopic Agglutination Testing

    PubMed Central

    Waggoner, Jesse J.; Balassiano, Ilana; Mohamed-Hadley, Alisha; Vital-Brazil, Juliana Magalhães; Sahoo, Malaya K.; Pinsky, Benjamin A.

    2015-01-01

    Background Reference diagnostic tests for leptospirosis include nucleic acid amplification tests, bacterial culture, and microscopic agglutination testing (MAT) of acute and convalescent serum. However, clinical laboratories often do not receive paired specimens. In the current study, we tested serum samples using a highly sensitive real-time nucleic acid amplification test for Leptospira and compared results to MAT performed on the same specimens. Methods/Principal Findings 478 serum samples from suspected leptospirosis cases in Rio de Janeiro were tested using a real-time RT-PCR for the diagnosis of leptospirosis, malaria and dengue (the Lepto-MD assay). The Lepto-MD assay detects all species of Leptospira (saprophytic, intermediate, and pathogenic), and in the current study, we demonstrate that this assay amplifies both Leptospira RNA and DNA. Dengue virus RNA was identified in 10 patients, and no cases of malaria were detected. A total of 65 samples (13.6%) were positive for Leptospira: 35 samples (7.3%) in the Lepto-MD assay, 33 samples (6.9%) by MAT, and 3 samples tested positive by both (kappa statistic 0.02). Poor agreement between methods was consistent regardless of the titer used to define positive MAT results or the day of disease at sample collection. Leptospira nucleic acids were detected in the Lepto-MD assay as late as day 22, and cycle threshold values did not differ based on the day of disease. When Lepto-MD assay results were added to the MAT results for all patients in 2008 (n=818), the number of detected leptospirosis cases increased by 30.4%, from 102 (12.5%) to 133 (16.3%). Conclusions/Significance This study demonstrates a lack of agreement between nucleic acid detection of Leptospira and single-specimen MAT, which may result from the clearance of bacteremia coinciding with the appearance of agglutinating antibodies. A combined testing strategy for acute leptospirosis, including molecular and serologic testing, appears necessary to maximize

  1. Prozone effects in microscopic agglutination tests for leptospirosis in the sera of mice infected with the pathogenic Leptospira interrogans serovar Canicola

    PubMed Central

    Shimabukuro, Fabio Hiroto; da Costa, Veruska Maia; da Silva, Rodrigo Costa; Langoni, Hélio; da Silva, Aristeu Vieira; de Carvalho, Lídia Raquel; Domingues, Paulo Francisco

    2013-01-01

    Mice experimentally infected with a pathogenic strain of Leptospira interrogans serovar Canicola produced false negative results (prozone effect) in a microscopic agglutination test (MAT). This prozone effect occurred in several serum samples collected at different post-infection times, but it was more prominent in samples collected from seven-42 days post-infection and for 1:50 and 1:100 sample dilutions. This phenomenon was correlated with increased antibody titres in the early post-infection phase. While prozone effects are often observed in serological agglutination assays for the diagnosis of animal brucellosis and human syphilis, they are not widely reported in leptospirosis MATs. PMID:23903987

  2. Direct appraisal of latex agglutination testing, a convenient alternative to enzyme immunoassay for the detection of rotavirus in childhood gastroenteritis, by comparison of two enzyme immunoassays and two latex tests.

    PubMed Central

    Sambourg, M; Goudeau, A; Courant, C; Pinon, G; Denis, F

    1985-01-01

    During February and March 1984, 207 fecal samples from infants and children with gastroenteritis were tested for rotavirus with four techniques: two enzyme immunoassays (Rotazyme; Abbott Laboratories, North Chicago, Ill., and Enzygnost-Rotavirus; Calbiochem-Behring, La Jolla, Calif.) and two latex agglutination tests (Rotalex; Orion Research, Inc., Cambridge, Mass., and Slidex Rota-Kit; Biomérieux). All stool samples were also tested for yeasts and bacterial pathogens. Electron microscopy was used to investigate discrepant results. We found 47% positive samples with Enzygnost-Rotavirus, 38% with Rotazyme, 37% with Slidex Rota-Kit, and 34% with Rotalex. No specimen was found positive by Rotazyme only or Slidex Rota-Kit only. On the contrary, 12 samples which were positive with Enzygnost-Rotavirus only and 3 which were positive with Rotalex only were not confirmed as positive by electron microscopy. Both enzyme immunoassays gave 6% equivocal results; Slidex Rota-Kit gave significantly fewer equivocal results than did Rotalex: 2.9% versus 9.7% (P less than 0.01). The sensitivity and specificity of latex tests compared favorably with that of enzyme immunoassays. Latex agglutination tests can be performed by unskilled personnel and are rapid and relatively cheap. They appear to be very suitable for routine laboratory work and may prove useful for large-scale screening in developing countries. PMID:2985650

  3. Direct appraisal of latex agglutination testing, a convenient alternative to enzyme immunoassay for the detection of rotavirus in childhood gastroenteritis, by comparison of two enzyme immunoassays and two latex tests.

    PubMed

    Sambourg, M; Goudeau, A; Courant, C; Pinon, G; Denis, F

    1985-04-01

    During February and March 1984, 207 fecal samples from infants and children with gastroenteritis were tested for rotavirus with four techniques: two enzyme immunoassays (Rotazyme; Abbott Laboratories, North Chicago, Ill., and Enzygnost-Rotavirus; Calbiochem-Behring, La Jolla, Calif.) and two latex agglutination tests (Rotalex; Orion Research, Inc., Cambridge, Mass., and Slidex Rota-Kit; Biomérieux). All stool samples were also tested for yeasts and bacterial pathogens. Electron microscopy was used to investigate discrepant results. We found 47% positive samples with Enzygnost-Rotavirus, 38% with Rotazyme, 37% with Slidex Rota-Kit, and 34% with Rotalex. No specimen was found positive by Rotazyme only or Slidex Rota-Kit only. On the contrary, 12 samples which were positive with Enzygnost-Rotavirus only and 3 which were positive with Rotalex only were not confirmed as positive by electron microscopy. Both enzyme immunoassays gave 6% equivocal results; Slidex Rota-Kit gave significantly fewer equivocal results than did Rotalex: 2.9% versus 9.7% (P less than 0.01). The sensitivity and specificity of latex tests compared favorably with that of enzyme immunoassays. Latex agglutination tests can be performed by unskilled personnel and are rapid and relatively cheap. They appear to be very suitable for routine laboratory work and may prove useful for large-scale screening in developing countries.

  4. Nationwide survey of leptospira antibodies in dogs in Japan: results from microscopic agglutination test and enzyme-linked immunosorbent assay.

    PubMed

    Iwamoto, Emiko; Wada, Yuko; Fujisaki, Yuka; Umeki, Saori; Jones, Miyuki Y; Mizuno, Takuya; Itamoto, Kazuhito; Maeda, Ken; Iwata, Hiroyuki; Okuda, Masaru

    2009-09-01

    Leptospirosis is an infectious disease caused by Leptospira interrogans sensu lato and is common in both humans and animals. In the present study, serum samples were collected from 801 dogs across all 47 prefectures in Japan, and evaluated with a microscopic agglutination test (MAT), using 5 major L. interrogans serovars (Icterohaemorrhagiae, Canicola, Autumnalis, Hebdomadis, and Australis) as antigens, and an enzyme-linked immunosorbent assay (ELISA) using recombinant OmpL1 protein as the antigen. Across all dogs tested, 217 (27.0%) and 29 (3.6%) were MAT- and ELISA-positive, respectively. However, evidence strongly suggests that MAT also detected antibodies produced by vaccination. Of 243 dogs never inoculated with any canine vaccine, 41 (16.9%) from 23 prefectures were MAT and/or ELISA positive. The most commonly detected serovar was Icterohaemorrhagiae (22 dogs, 19 prefectures). Our results suggest that there are dogs with subclinical Leptospira infection throughout Japan. To the best of our knowledge, the present study is the first nationwide survey of Leptospira infection in dogs, and the findings are relevant not only for clinical veterinary medicine but also for public health.

  5. Urine specific gravity test

    MedlinePlus

    ... medlineplus.gov/ency/article/003587.htm Urine specific gravity test To use the sharing features on this page, please enable JavaScript. Urine specific gravity is a laboratory test that shows the concentration ...

  6. Selective mineral composition, functional test morphology and paleoecology of the agglutinated foraminiferal genus Colominella Popescu, 1998 in the Mediterranean Pliocene (Liguria, Italy)

    NASA Astrophysics Data System (ADS)

    Nicoletta, Mancin; Elena, Basso; Camilla, Pirini; Michael A., Kaminski

    2012-12-01

    Specimens of Colominella (agglutinated Foraminifera) from a Pliocene Mediterranean succession were analysed through a scanning electron microscope (SEM) equipped with an energy-dispersive X-ray spectrometer (EDX) to document their test microstructure. Colominella develops a complex large test with a mostly biserial chamber arrangement, but with the internal chamber lumens partitioned by vertical and horizontal plates that form a labyrinthine structure of alcoves. This internal partition occurs from the first chambers but is completely masked from the outside by the thick wall. The test-wall microstructure is characterized by canaliculi (parapores) that are externally covered by a pavement of agglutinated grains. The mineralogical characterization of the agglutinated grains and the secreted cement shows that the grains are strongly selected as regards to size, arrangement and composition, with the coarse grains placed close to the outer wall. Moreover, these coarse grains, forming a pavement, are made of monocrystalline quartz, whereas the inner part of the skeleton is mostly composed of dolomite. The carbonate cement is less abundant and appears as cloudy light grey areas among the detrital grains. These shell features can be interpreted as functional adaptations to perform kleptoplastidy and/or to house functional photosymbionts, probably induced by stable environmental conditions as in warm shallow waters characterized by low nutrient flux.

  7. Traces of dissolved particles, including coccoliths, in the tests of agglutinated foraminifera from the Challenger Deep (10,897 m water depth, western equatorial Pacific)

    NASA Astrophysics Data System (ADS)

    Gooday, A. J.; Uematsu, K.; Kitazato, H.; Toyofuku, T.; Young, J. R.

    2010-02-01

    We examined four multilocular agglutinated foraminiferan tests from the Challenger Deep, the deepest point in the world's oceans and well below the depth at which biogenic and most detrital minerals disappear from the sediment. The specimens represent undescribed species. Three are trochamminaceans in which imprints and other traces of dissolved agglutinated particles are visible in the orange or yellowish organic test lining. In Trochamminacean sp. A, a delicate meshwork of organic cement forms ridges between the grain impressions. The remnants of test particles include organic structures identifiable as moulds of coccoliths produced by the genus Helicosphaera. Their random alignment suggests that they were agglutinated individually rather than as fragments of a coccosphere. Trochamminacean sp. C incorporates discoidal structures with a central hole; these probably represent the proximal sides of isolated distal shields of another coccolith species, possibly Hayaster perplexus. Imprints of planktonic foraminiferan test fragments are also present in both these trochamminaceans. In Trochamminacean sp. B, the test surface is densely pitted with deep, often angular imprints ranging from roughly equidimensional to rod-shaped. The surfaces are either smooth, or have prominent longitudinal striations, probably made by cleavage traces. We presume these imprints represent mineral grains of various types that subsequently dissolved. X-ray microanalyses reveal strong peaks for Ca associated with grain impressions and coccolith remains in Trochamminacean sp. C. Minor peaks for this element are associated with coccolith remains and planktonic foraminiferan imprints in Trochamminacean sp. A. These Ca peaks possibly originate from traces of calcite remaining on the test surfaces. Agglutinated particles, presumably clay minerals, survive only in the fourth specimen (' Textularia' sp.). Here, the final 4-5 chambers comprise a pavement of small, irregularly shaped grains with flat

  8. Specificity of quantitative latex agglutination assay for D-dimer in exclusion of pulmonary embolism in the emergency department.

    PubMed

    Stein, Paul D; Matta, Fadi; Sabra, Michel J; Tana, Christopher; Gough, Andrew; Chabala, Steve; Kakish, Edward; Tworek, Joseph

    2014-11-01

    We assessed the prevalence of elevated quantitative latex agglutination assay for D-dimer in patients in the emergency department in whom pulmonary embolism (PE) was excluded. D-dimer was normal (<230 ng/mL) in 435 (83%) of the 522 patients. D-dimer was normal in 88% of the patients with musculoskeletal or related chest pain, 74% with pleurisy or pleuritic chest pain, and 85% with upper respiratory tract infection. D-dimer was 230 to 500 ng/mL in 65 (75%) of the 87 in whom D-dimer was elevated. Clinical probability was low in 31 (48%) of the 65 patients with D-dimer levels of 230 to 500 ng/mL. D-dimer was 230 to 500 ng/mL and clinical probability was low in 31 (36%) of the 87 patients who had computed tomographic (CT) angiograms because of elevated D-dimer. Negative likelihood ratio for PE is sufficiently low that PE can be excluded with reasonable certainty in such patients. Tailoring cutoff value to 500 ng/mL in patients with low clinical probability would have reduced CT angiograms by 36%.

  9. Evaluation of chromogenic medium and direct latex agglutination test for detection of group B streptococcus in vaginal specimens from pregnant women in Lebanon and Kuwait.

    PubMed

    Ghaddar, Nahed; Alfouzan, Wadha; Anastasiadis, Elie; Al Jiser, Tamima; Itani, Saad Eddine; Dernaika, Racha; Eid, Toufic; Ghaddar, Ali; Charafeddine, Adib; Dhar, Rita; El Hajj, Hiba

    2014-10-01

    This study was undertaken to evaluate chromogenic medium and a direct latex agglutination test (DLA) for detection of Group B Streptococcus (GBS) in the vaginal specimens of pregnant women, and to ascertain the prevalence of GBS in this population in Kuwait and Lebanon. Vaginal swabs, collected from women at 35-37 weeks of gestation, were cultured on 5 % sheep blood agar (SBA), colistin nalidixic acid agar (CNA), Strept B Select chromogenic agar (SBS) as well as Lim enrichment broth in 168 cases in Lebanon while only SBA was used for 1391 samples in Kuwait. In addition, vaginal samples from 102 GBS-positive and 20 GBS-negative women near the time of delivery were collected in Kuwait for evaluation of the DLA test. During the study period, the prevalence of GBS colonization was determined to be 20.7 % (288/1391) in Kuwait while 18.4 % (31) of 168 pregnant women in Lebanon had vaginal cultures positive for GBS. By direct plating of vaginal swabs on the three media used, the isolation rates of GBS were 51.6, 64.5 and 77.4 % on SBA, CNA and SBS, respectively, which increased to 90.35, 93.1 and 96.8 %, respectively, following subculture in Lim broth after 18 h of incubation. The sensitivity of the DLA test was found to be dependent on the density of GBS colonization, resulting in 100 % sensitivity and 100 % specificity for heavy (>10(2) c.f.u. per swab) and moderately heavy (50-100 c.f.u. per swab) growth of GBS. However, for vaginal specimens yielding <50 c.f.u. per swab, the sensitivity, specificity, positive and negative predictive values of the DLA test were 100, 55.5, 63.6 and 100 %, respectively. In conclusion, a chromogenic agar, such as SBS, and a DLA test can be used for rapid detection of GBS in pregnant women. The DLA test, in particular, could prove to be a useful tool for immediate detection of GBS in women near delivery so that intrapartum antibiotic prophylaxis can be initiated.

  10. Serological evidence of Leishmania donovani infection in apparently healthy dogs using direct agglutination test (DAT) and rk39 dipstick tests in Kafta Humera, north-west Ethiopia.

    PubMed

    Kalayou, S; Tadelle, H; Bsrat, A; Abebe, N; Haileselassie, M; Schallig, H D F H

    2011-06-01

    Leishmania (Kinetoplastida: Trypanosomatidae) are protozoan parasites of significant medical and veterinary importance. Over the last decade, visceral leishmaniasis (VL) has emerged as a major opportunistic infection associated with HIV/AIDS in North Western Ethiopia. This paper reports on serological evidence of possible Leishmania donovani (L. donovani) infection in dogs using two serological tests: direct agglutination test (DAT) and Kalazar detect rapid test (KDRT). Two hundred and seventeen asymptomatic local breed dogs were examined for L. donovani antibodies. Performance of the DAT and KDRT was assessed in 162 matching samples of blood collected on filter paper and serum, respectively. Using DAT and KDRT testing in parallel, the overall seroprevalence of L. donovani infection was 27.7% and 14.8%, respectively. The degree of agreement was found to be fair (68.8%, k = 0.234). Univariable logistic regression analysis of some risk factors for L. donovani infection in dogs using DAT indicates that place of residence, sex, age, dog keeping purpose and dog housing condition were not significantly associated with seropositivity. The high proportion of positive dogs suggests the exposure of these animals to L. donovani infection and needs further investigation. Isolation and typing of the parasite aiming at confirming the role of these animals in maintenance and transmission of kala-azar is advocated.

  11. Detection of staphylococcal exfoliative toxin by slide latex agglutination.

    PubMed Central

    Murono, K; Fujita, K; Yoshioka, H

    1988-01-01

    A simple and rapid method in which slide latex agglutination was used was developed to detect the exfoliative toxin (ET) elaborated by clinical isolates. ET types A and B (ET-A and ET-B) were purified by plate gel isoelectrofocusing, and anti-ET sera were obtained by immunizing rabbits. A specific immunoglobulin G antitoxin was then prepared from the immunized rabbit sera by fast protein liquid chromatography, and latex particles were coated with the antitoxin. Of 74 staphylococcal strains isolated from patients with staphylococcal scalded skin syndrome, 61 strains were found to produce ET by the newborn mouse bioassay. All 61 strains were shown to be positive for ET-A and ET-B production by the slide latex agglutination method. The lowest concentration of ETs detected by the latex agglutination method was 0.5 microgram/ml, which was much lower than that detected by the double immunodiffusion method, with a sensitivity of 50 micrograms/ml. It is crucial to prove ET production by clinical isolates for the diagnosis and surveillance of staphylococcal scalded skin syndrome. The latex agglutination method is a sensitive, simple, and rapid test which can be used as an alternative to the newborn mouse bioassay. Images PMID:3343322

  12. Comparison of latex agglutination, wet preparation, and culture for the detection of Trichomonas vaginalis

    PubMed Central

    Adu-Sarkodie, Y; Opoku, B; Danso, K; Weiss, H; Mabey, D

    2004-01-01

    Objectives: To compare the performance of three diagnostic methods for Trichomonas vaginalis infection—latex agglutination, saline wet mount, and culture. Methods: Vaginal swabs from 3807 women attending antenatal clinics were tested for the presence of T vaginalis by latex agglutination. All positives and the following two negatives were tested by wet preparation and culture. Results: The prevalence of infection by latex agglutination was 5.4%. Using an expanded gold standard based on the wet mount and culture results, the sensitivity of the latex agglutination test was 98.8% (95% CI 95.9 to 99.9) and specificity was 92.1 (89.2 to 94.5). The kappa index for test agreement was 0.93 for latex and culture and 0.88 for latex and wet preparation. Conclusion: The latex agglutination test is a highly sensitive test for detecting T vaginalis infection. It is a simple rapid test and has the potential for use in screening and diagnostic settings. PMID:15170003

  13. Usefulness of the rK39-Immunochromatographic Test, Direct Agglutination Test, and Leishmanin Skin Test for Detecting Asymptomatic Leishmania Infection in Children in a New Visceral Leishmaniasis Focus in Amhara State, Ethiopia

    PubMed Central

    Gadisa, Endalamaw; Custodio, Estefanía; Cañavate, Carmen; Sordo, Luis; Abebe, Zelalem; Nieto, Javier; Chicharro, Carmen; Aseffa, Abraham; Yamuah, Lawrence; Engers, Howard; Moreno, Javier; Cruz, Israel

    2012-01-01

    In areas where visceral leishmaniasis is anthroponotic, asymptomatically infected patients may play a role in transmission. Additionally, the number of asymptomatic patients in a disease-endemic area will also provide information on transmission dynamics. Libo Kemkem and Fogera districts (Amhara State, Ethiopia) are now considered newly established areas to which visceral leishmaniasis is endemic. In selected villages in these districts, we conducted a study to assess the usefulness of different approaches to estimate the asymptomatic infection rate. Of 605 participants, the rK39 immunochromatographic test was able to detect asymptomatic infection in 1.5% (9 of 605), direct agglutination test in 5.3% (32 of 605), and leishmanin skin test in 5.6% (33 of 589); the combined use of serologic methods and leishmanin skin test enabled detecting asymptomatic infection in 10.1% (61 of 605). We conclude that the best option to detect asymptomatic infection in this new visceral leishmaniasis–endemic focus is the combined use of the direct agglutination test and the leishmanin skin test. PMID:22556076

  14. Evaluation of the usefulness of six commercial agglutination assays for serologic diagnosis of toxoplasmosis.

    PubMed

    Villard, Odile; Cimon, Bernard; Franck, Jacqueline; Fricker-Hidalgo, Hélène; Godineau, Nadine; Houze, Sandrine; Paris, Luc; Pelloux, Hervé; Villena, Isabelle; Candolfi, Ermanno

    2012-07-01

    Six agglutination tests for detecting Toxoplasma gondii-specific antibodies (immunoglobulin G or M) in serum were performed and compared. In total, 599 sera were examined using direct and indirect agglutination assays. Sensitivity varied from 93.7% to 100% and specificity from 97.1% to 99.2%. In a selected population with interfering diseases, the percentage of false positives ranged from 4.3% to 10.9%. Although an overall agreement of 100% was found for chronic toxoplasmosis, sensitivity for the detection of confirmed acute toxoplasmosis ranged from 86.4% to 97.3%. Regarding the large variability in terms of the performance of the 6 assays, tests based on the hemagglutination principle were found to be better than the other agglutination tests for all the panels evaluated, meaning that they could be used as qualitative or semiquantitative low-cost screening assays.

  15. Short report: Seroprevalence of human leptospirosis in Reunion Island (Indian Ocean) assessed by microscopic agglutination test on paper disc-absorbed whole blood.

    PubMed

    Desvars, Amélie; Gigan, Jimmy; Hoarau, Géraldine; Gérardin, Patrick; Favier, François; Michault, Alain

    2011-12-01

    In the last decade, leptospirosis has emerged as a globally important infectious disease. Humans most commonly become infected through occupational, recreational, or domestic contact with the urine of carrier animals, either directly or through contaminated water or soil. The disease occurs in urban areas of industrialized and developing countries as well as rural regions worldwide. We present a retrospective study conducted in 2006 on 2,269 randomly selected Reunion Island inhabitants. Blood sampling was performed on individual blotting papers, and microscopic agglutination test (MAT) was conducted on paper disc-absorbed (PDA) blood. We showed that seroprevalence of leptospirosis was 0.66% ± 0.34 in the global population of Reunion Island, which is 1.78 lower than the seroprevalence estimated 20 years before. The serological method is described, and the results discussion focuses on methodology and socio-economic factors.

  16. Penicillamine prevents ram sperm agglutination in media that support capacitation.

    PubMed

    Leahy, T; Rickard, J P; Aitken, R J; de Graaf, S P

    2016-02-01

    Ram spermatozoa are difficult to capacitate in vitro. Here we describe a further complication, the unreported phenomenon of head-to-head agglutination of ram spermatozoa following dilution in the capacitation medium Tyrodes plus albumin, lactate and pyruvate (TALP). Sperm agglutination is immediate, specific and persistent and is not associated with a loss of motility. Agglutination impedes in vitro sperm handling and analysis. So the objectives of this study were to investigate the cause of sperm agglutination and potential agents which may reduce agglutination. The percentage of non-agglutinated, motile spermatozoa increased when bicarbonate was omitted from complete TALP suggesting that bicarbonate ions stimulate the agglutination process. d-penicillamine (PEN), a nucleophilic thiol, was highly effective at reducing agglutination. The inclusion of 250 μM PEN in TALP reduced the incidence of motile, agglutinated spermatozoa from 76.7 ± 2.7% to 2.8 ± 1.4%. It was then assessed if PEN (1 mM) could be included in existing ram sperm capacitation protocols (TALP +1 mM dibutyryl cAMP, caffeine and theophylline) to produce spermatozoa that were simultaneously capacitated and non-agglutinated. This protocol resulted in a sperm population which displayed high levels of tyrosine phosphorylated proteins and lipid disordered membranes (merocyanine-540) while remaining motile, viable, acrosome-intact and non-agglutinated. In summary, PEN (1 mM) can be included in ram sperm capacitation protocols to reduce sperm agglutination and allow for the in vitro assessment of ram sperm capacitation.

  17. Validation of the modified agglutination test for the detection of Toxoplasma gondii in free-range chickens by using cat and mouse bioassay.

    PubMed

    Dubey, J P; Laurin, E; Kwowk, O C H

    2016-03-01

    The modified agglutination test (MAT) is one of the most commonly used tests for the detection of antibodies to Toxoplasma gondii in animal and human sera. The objective of the present study was to evaluate the diagnostic accuracy of the MAT and bioassay in free-range/backyard (FR) chickens (Gallus domesticus). Previously-published T. gondii test results from 2066 chickens from 19 countries were compiled for the present study. The frequency of isolation of T. gondii increased for MAT titres between 1:5 and 1:160, and ranged from 61 to 75% for antibody titres of 1:160, 1:320, and ⩾1:640. Twenty-three cats fed pooled hearts from a total of 802 FR seronegative (MAT, <1:5) chickens from several countries did not excrete oocysts, indicating a high negative predictive value of MAT because FR chickens would have been exposed to many microbes; cats are the most sensitive indicators of T. gondii infection in tissues and can excrete millions of oocysts after ingesting even a few bradyzoites. Of the 29 cats in this study, six cats, fed hearts pooled from 15-122 FR chickens, excreted oocysts; but these identifications were likely related to misidentification or prozone. Results of the present study support the validity of MAT for the detection of T. gondii infection in chickens.

  18. Simulation of Mechanical Behavior of Agglutinates

    NASA Technical Reports Server (NTRS)

    Nakagawa, Masami; Moon, Tae-Hyun

    2005-01-01

    Due to lack of "real" lunar soil or even lunar simulant, it is difficult to characterize the interaction between lunar soil (or simulant) with different surfaces that are involved in excavation and processing machinery. One unique feature possessed by lunar soil is the agglutinates produced by repeated high-speed micrometeoroid impacts and subsequent pulverization[l and 2]. The large particles are impacted by micrometeoroids [Fig.l] and pulverized to produce finer particles. This process continues until there are no more "large" particles left on the surface of the moon. Due to high impact speed, the impact melting process fuses fines to make agglutinates such as shown in Fig. 2. We will present a series of simulation results and movies will be shown to indicate brittle behavior of each individual agglutinate and also similar compressibility charts shown by Carrier et al. [3]. Fig. 3 shows our preliminary result of the simulated oedometer tests.

  19. Specific construction tests

    NASA Technical Reports Server (NTRS)

    Mcrae, W. V., Jr.

    1980-01-01

    The technical feasibility of the Satellite Power System (SPS) is discussed. The development of feasible operational concepts and conceptualization of specific construction tasks are examined. The logic flow of functional analyses of both the rectenna and the satellite is illustrated. Constraints placed upon the construction processes and equipment by the satellite design are outlined. The construction tasks, when defined and combined into an integrated schedule establish, a time line for construction mass flow demands to be satisfied by the space transportation systems. An example of satellite constructive demands and HLLV delivery capabilities is given.

  20. The usefulness of direct agglutination test, enzyme-linked immunosorbent assay and polymerase chain reaction for the detection of Toxoplasma gondii in wild animals.

    PubMed

    Kornacka, Aleksandra; Cybulska, Aleksandra; Bień, Justyna; Goździk, Katarzyna; Moskwa, Bożena

    2016-09-15

    The aim of the study was to compare the usefulness of two antibody-based methods, the direct agglutination test (DAT) and enzyme linked immuosorbent assay (ELISA), with that of the polymerase chain reaction (PCR) for detecting anti-Toxoplasma gondii in samples derived from naturally-infected wild animals. Antibodies against T. gondii were detected in meat juice samples collected from 129 free- living carnivores and omnivores. T. gondii seroprevalence was confirmed in 73,6% of examined samples when DAT and ELISA were used separately, but in only 88,4% samples when both immunological tests were used in parallel. PCR results confirmed the presence of DNA of the parasite in 24 of all the 129 samples. Sixteen samples were classified as positive when all three tests were used. A moderate degree of agreement was found between DAT and ELISA (κ=0.55). However, no agreement was found between the molecular and serological tests: κ=-1.75 for DAT versus PCR; κ=-1.67 ELISA versus PCR. By using both serological tests, antibodies against T. gondii were found in 77.5% of red foxes, 12.5% of badgers, 40% of martens and 8.3% of raccoon dogs. Antibodies against the parasite were detected also in one mink, but not in the sample derived from a polecat. T.gondii DNA was found in the brain tissue of 20 red foxes, three badgers and one raccoon dog. Our studies confirm that ELISA and DAT are suitable and reliable techniques for T. gondii antibody detection in meat juice from wild animals when serum samples are unavailable. Positive results obtained by immunological tests do not always reflect that the host was infected by T. gondii. They indicate only a contact with parasite. PCR should be used to confirm te presence of DNA from T. gondii.

  1. Comparison of the dot-immunobinding assay with the serum agglutination test, the rose bengal plate test and the milk ring test for the detection of Brucella antibodies in bovine sera and milk.

    PubMed

    Gürtürk, K; Boynukara, B; Ilhan, Z; Hakki Ekin, I; Gülhan, T

    1999-05-01

    In this study, Brucella antibodies in bovine sera and milk were detected using the dot-immunobinding assay (DIA), the serum agglutination test (SAT), the Rose Bengal plate test (RBPT) and the milk ring test (MRT). For this purpose, a total of 116 paired blood and milk samples collected at the same time from 56 aborted and from 60 healthy dairy cows was examined. In DIA, a nitrocellulose membrane (NCM) was used as the solid phase. Antigen adsorbed on the NCM was extracted from Brucella abortus S99 by heat treatment. The results obtained by DIA were compared with those of SAT, RBPT and MRT. Of the 116 paired blood and milk samples, 24 were positive and 72 were negative by all tests used. Serum samples of six aborted cows were positive by DIA, SAT and RBPT but the milk samples were negative by DIA and MRT. Serum and milk samples of four aborted cows gave positive reaction only by DIA tests. The remaining six aborted cows were negative only by MRT and two of them were negative by both RBPT and MRT. Four sera of healthy cows were found to be positive only by SAT.

  2. Detection of Salmonella enterica serovar Enteritidis (SE) Antibodies in Serum Using A Polystyrene Bead/SE Flagella Agglutination Assay

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Serologic screening of flocks can be an important method to detect Salmonella enteritidis (SE) infections but can be labor intensive or lack specificity. Our goal was to develop a rapid agglutination assay using SE flagella adsorbed to polystyrene beads as a simple, relatively specific test to dete...

  3. Specific test and evaluation plan

    SciTech Connect

    Hays, W.H.

    1998-03-20

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made to the 241-AX-B Valve Pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.

  4. Specific test and evaluation plan

    SciTech Connect

    Hays, W.H.

    1997-12-09

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made to the 241-AN-A Valve Pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a ``lower tier`` document based on the W-314 Test and Evaluation Plan (TEP) This STEP encompasses all testing activities required to demonstrate compliance to the project design criteria as it relates to the modifications of the AN-A valve pit. The Project Design Specifications (PDS) identify the specific testing activities required for the Project. Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the modifications to the 241-AN-A Valve Pit. The STEP will be utilized in conjunction with the TEP for verification and validation.

  5. MEMS reagent and sample handling procedure: Feasibility of viral antibody detection by passive immune agglutination

    NASA Technical Reports Server (NTRS)

    Bailey, G. D.; Tenoso, H. J.

    1975-01-01

    An attempt was made to develop a test requiring no preadsorption steps for the assessment of antibodies to rubella and mumps viruses using the passive immune agglutination (PIA) method. Both rubella and mumps antigens and antibodies were prepared. Direct PIA tests, using rubella antigen-coated beads, and indirect PIA tests, using rubella antibody-coated beads, were investigated. Attempts, using either method, were unsuccessful. Serum interference along with nonspecific agglutination of beads by the rubella antigen resulted in no specific response under the test conditions investigated. A new, highly sensitive approach, the enzyme immunoassay (EIA) test system, is recommended to overcome the nonspecificity. This system is a logical outgrowth of some of the solid phase work done on MEMS and represents the next generation tests system that can be directly applied to early disease detection and monitoring.

  6. INACTIVATION OF SEXUAL AGGLUTINATION IN HANSENULA WINGEI AND SACCHAROMYCES KLUYVERI BY DISULFIDE-CLEAVING AGENTS.

    PubMed

    TAYLOR, N W

    1964-10-01

    Taylor, Neil W. (Northern Regional Research Laboratory, Peoria, Ill.). Inactivation of sexual agglutination in Hansenula wingei and Saccharomyces kluyveri by disulfide-cleaving agents. J. Bacteriol. 88:929-936. 1964.-Mating types of both Hansenula wingei and Saccharomyces kluyveri can be activated to produce uniformly strong sexual agglutination by treatments with various solvents, such as 8 m LiBr. The strongly agglutinative mating-type preparations were irreversibly inactivated for sexual agglutination by various chemical treatments. Type 5 of H. wingei was inactivated by disulfide-cleaving reagents, but type 21 of H. wingei was not. Type 3 of S. kluyveri was more sensitive than type 26 of S. kluyveri to inactivation by disulfide-cleaving reagents. Comparison of sensitivities to these and other treatments, plus a moderately strong cross-agglutination between type 3 and type 21, indicated that the sexually agglutinative elements on type 3 are similar to type 5, and those of type 21 are similar to those of type 26. Inactivation-rate experiments showed a loss of agglutinative ability according to a sigmoid decrement with time for both types 5 and 21. The apparent extent of inactivation depended markedly on agglutination test conditions. Results of these experiments were interpreted to indicate tentatively, first, that the agglutinative elements of both types of a species are proteins and, second, that several agglutinating linkages are formed between any two cells in sexual agglutination.

  7. Diagnosis of myocardial infarction based on lectin-induced erythrocyte agglutination: a feasibility study

    NASA Astrophysics Data System (ADS)

    Bocsi, József; Nieschke, Kathleen; Mittag, Anja; Reichert, Thomas; Laffers, Wiebke; Marecka, Monika; Pierzchalski, Arkadiusz; Piltz, Joachim; Esche, Hans-Jürgen; Wolf, Günther; Dähnert, Ingo; Baumgartner, Adolf; Tarnok, Attila

    2014-03-01

    Myocardial infarction (MI) is an acute life-threatening disease with a high incidence worldwide. Aim of this study was to test lectin-carbohydrate binding-induced red blood cell (RBC) agglutination as an innovative tool for fast, precise and cost effective diagnosis of MI. Five lectins (Ricinus communis agglutinin (RCA), Phaseolus vulgaris erythroagglutinin (PHA), Datura stramonium agglutinin (DSA), Artocarpus agglutinin (ArA), Triticum agglutinin (TA)) were tested for ability to differentiate between agglutination characteristics in patients with MI (n = 101) or angina pectoris without MI (AP) (n = 34) and healthy volunteers (HV) as control (n =68) . RBC agglutination was analyzed by light absorbance of a stirred RBC suspension in the green to red light spectrum in an agglutimeter (amtec, Leipzig, Germany) for 15 min after lectin addition. Mean cell count in aggregates was estimated from light absorbance by a mathematical model. Each lectin induced RBC agglutination. RCA led to the strongest RBC agglutination (~500 RBCs/aggregate), while the others induced substantially slower agglutination and lead to smaller aggregate sizes (5-150 RBCs/aggregate). For all analyzed lectins the lectin-induced RBC agglutination of MI or AP patients was generally higher than for HV. However, only PHA induced agglutination that clearly distinguished MI from HV. Variance analysis showed that aggregate size after 15 min. agglutination induced by PHA was significantly higher in the MI group (143 RBCs/ aggregate) than in the HV (29 RBC-s/aggregate, p = 0.000). We hypothesize that pathological changes during MI induce modification of the carbohydrate composition on the RBC membrane and thus modify RBC agglutination. Occurrence of carbohydrate-lectin binding sites on RBC membranes provides evidence about MI. Due to significant difference in the rate of agglutination between MI > HV the differentiation between these groups is possible based on PHA-induced RBC-agglutination. This novel assay

  8. [Diagnostic value of agglutination reaction with buffered Brucella antigen stained with rose bengal].

    PubMed

    Chenchev, I; Khristoforov, L; Peshkov, I; Kostov, G; Mineva, I

    1978-01-01

    A specific buffered antigen has been obtained, employing a method developed by the authors, stained with Bengal rose and intended for performing a fast agglutination reaction to confirm brucellosis. The antigen produces a clear and demonstrative agglutination reaction with positive sera. Practically, the test is readily carried out, and can be made a routine both in every serologic laboratory and for investigations under field conditions. The reaction produced with this antigen can determine dependably the epizootic status on a farm or in the herd. The diagnostic value of the antigen is essential, especially with swine. Besides, it shows a wide a diagnostic scope for brucellosis with all species of animals (97--98 per cent).

  9. Mannanoligosaccharide agglutination by Salmonella enterica strains isolated from carrier pigs

    PubMed Central

    Borowsky, Luciane; Corção, Gertrudes; Cardoso, Marisa

    2009-01-01

    Type-1 fimbriae are associated with most Salmonella enterica serovars and are an essential factor for host colonization. Mannanoligosaccharides (MOS), a prebiotic that is agglutinated by type-1 fimbriae, are proposed for the control of enterobacteria colonization and may be an alternative to Salmonella control in pigs. The aim of this study was to evaluate the capability of porcine Salmonella strains to adhere to MOS in vitro. A total of 108 strains of Salmonella sp. isolated from carrier pigs were evaluated for the amplification of fimA and fimH genes, agglutination of MOS and hemagglutination. In all tested strains, amplicons of expected size were detected for both fimA and fimH gene. In the hemagglutination assays, 31 (28.7%) strains presented mannose–sensitive agglutination of erythrocytes, indicating that the strains were expressing type-1 fimbriae. Considering only strains expressing the type-1 fimbriae, 23 (74.2%) presented a strong agglutination of MOS, 3 (9.6%) a weak reaction and 5 (16.2%) none. The results indicate that Salmonella enterica strains expressing type-1 fimbriae can agglutinate effectively in vitro to MOS. PMID:24031388

  10. 21 CFR 660.26 - Specificity tests and avidity tests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Specificity tests and avidity tests. 660.26 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.26 Specificity tests and avidity tests. Specificity and avidity tests shall be performed using...

  11. 21 CFR 660.26 - Specificity tests and avidity tests.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Specificity tests and avidity tests. 660.26... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.26 Specificity tests and avidity tests. Specificity and avidity tests shall be...

  12. A Rapid In-Clinic Test Detects Acute Leptospirosis in Dogs with High Sensitivity and Specificity

    PubMed Central

    Kodjo, Angeli; Calleja, Christophe; Loenser, Michael; Lin, Dan; Lizer, Joshua

    2016-01-01

    A rapid IgM-detection immunochromatographic test (WITNESS® Lepto, Zoetis) has recently become available to identify acute canine leptospirosis at the point of care. Diagnostic sensitivity and specificity of the test were evaluated by comparison with the microscopic agglutination assay (MAT), using a positive cut-off titer of ≥800. Banked serum samples from dogs exhibiting clinical signs and suspected leptospirosis were selected to form three groups based on MAT titer: (1) positive (n = 50); (2) borderline (n = 35); and (3) negative (n = 50). Using an analysis to weight group sizes to reflect French prevalence, the sensitivity and specificity were 98% and 93.5% (88.2% unweighted), respectively. This test rapidly identifies cases of acute canine leptospirosis with high levels of sensitivity and specificity with no interference from previous vaccination. PMID:27110562

  13. A Rapid In-Clinic Test Detects Acute Leptospirosis in Dogs with High Sensitivity and Specificity.

    PubMed

    Kodjo, Angeli; Calleja, Christophe; Loenser, Michael; Lin, Dan; Lizer, Joshua

    2016-01-01

    A rapid IgM-detection immunochromatographic test (WITNESS® Lepto, Zoetis) has recently become available to identify acute canine leptospirosis at the point of care. Diagnostic sensitivity and specificity of the test were evaluated by comparison with the microscopic agglutination assay (MAT), using a positive cut-off titer of ≥800. Banked serum samples from dogs exhibiting clinical signs and suspected leptospirosis were selected to form three groups based on MAT titer: (1) positive (n = 50); (2) borderline (n = 35); and (3) negative (n = 50). Using an analysis to weight group sizes to reflect French prevalence, the sensitivity and specificity were 98% and 93.5% (88.2% unweighted), respectively. This test rapidly identifies cases of acute canine leptospirosis with high levels of sensitivity and specificity with no interference from previous vaccination.

  14. Synthesis for Lunar Simulants: Glass, Agglutinate, Plagioclase, Breccia

    NASA Technical Reports Server (NTRS)

    Weinstein, Michael; Wilson, Stephen A.; Rickman, Douglas L.; Stoeser, Douglas

    2012-01-01

    The video describes a process for making glass for lunar regolith simulants that was developed from a patented glass-producing technology. Glass composition can be matched to simulant design and specification. Production of glass, pseudo agglutinates, plagioclase, and breccias is demonstrated. The system is capable of producing hundreds of kilograms of high quality glass and simulants per day.

  15. Overall evaluation of an immunological latex agglutination system for fecal occult blood testing in the colorectal cancer screening program of Florence.

    PubMed

    Rubeca, Tiziana; Peruzzi, Benedetta; Confortini, Massimo; Rapi, Stefano

    2012-10-08

    Several immunological fecal occult blood tests (FOBT) are currently available for colorectal cancer (CRC) screening. We compared the HM Jack (Jack) (Kiowa, Japan), with the OC-Hemodia (OC) (Eiken, Japan) in use in the Florence screening program. Aims of the study were: (i) to investigate the diagnostic performance and the best cutoff value for Jack; (ii) to evaluate the handiness of sampling tubes; (iii) to compare costs. A total of 5,044 subjects were screened with both tests. Sampling tube investigation was performed running each sample on both instruments. A number of 352 subjects positive for at least one test (175 OC, 310 Jack) were selected for further investigations, while 46 subjects refused further assessments. Analysis of costs related to the assessment phase was performed on the basis of Tuscany region's fares. Amongst the 306 subjects investigated, 9 CRC and 67 advanced adenomas (AdA) were detected. Detection rates (DR) were 1.4‰ for CRC and 9.6‰ for AdA. After Jack cutoff optimization, DR for CRC+AdA resulted in 11.1‰ for OC and 13.3‰ for Jack (p=0.041). Sensitivity of the methods was 73.7 for OC and 88.2 for Jack; specificity was 97.6 for OC and 96.0 for Jack, resulting in an increase of the required assessments from 3.5% to 5.1%. No differences were observed between sampling methods. Despite the lower specificity of Jack, its greater sensitivity makes the method attractive for screening programs. An increase of the costs of 30% for every subject investigated for pathological lesion (CRC+AdA) may be thus foreseen.

  16. Prostate-specific antigen (PSA) blood test

    MedlinePlus

    Prostate-specific antigen; Prostate cancer screening test; PSA ... special steps are needed to prepare for this test. ... Reasons for a PSA test: This test may be done to screen for prostate cancer. It is also used to follow people after prostate cancer ...

  17. Performance of commercial ELISA and agglutination test kits for the detection of anti-Toxoplasma gondii antibodies in serum and muscle fluid of swine infected with 100, 300, 500 or 1000 oocysts.

    PubMed

    Forbes, Lorry B; Parker, Sarah E; Gajadhar, Alvin A

    2012-12-21

    Serum and tissue fluid samples from experimentally infected swine were tested for antibodies to Toxoplasma gondii using both an indirect ELISA and a modified agglutination test (MAT) available commercially in kit form. Ten 8-9 week-old swine were fed meatballs containing 100, 300, 500 or 1000 T. gondii oocysts and three control animals were fed meatballs with no oocysts. Post-inoculation blood samples were collected weekly until euthanasia at 35-63 days post inoculation (DPI). Tissue fluid was obtained from diaphragm, heart and sternomastoideus muscles post-mortem. By 16 DPI, nine of 10 inoculated pigs were detected serologically using ELISA at a pre-test serum dilution of 1:50 and all ten pigs were detected by the MAT at a serum dilution of 1:25. The last pig became positive on ELISA by 21 DPI and the 10 pigs maintained their serological status for the duration of the experiment. Heart muscle was the best overall source of tissue fluid for ELISA and all six pigs inoculated with either 500 or 1000 oocysts were positive using either diaphragm or heart tissue fluid samples. However, 10 of 18 fluid samples from pigs receiving ≤ 300 oocysts were not detected using ELISA, including 5 of 6 from sternomastoideus muscle. The MAT used at a 1:10 pre-test dilution of tissue fluid correctly identified all 10 inoculated pigs regardless of the source muscle. Based on these data, we conclude that either assay would be useful for herd evaluation or surveillance testing using sera, and the MAT would be a good candidate assay for testing tissue fluid for the same purposes.

  18. Specificity of a Maximal Step Exercise Test

    ERIC Educational Resources Information Center

    Darby, Lynn A.; Marsh, Jennifer L.; Shewokis, Patricia A.; Pohlman, Roberta L.

    2007-01-01

    To adhere to the principle of "exercise specificity" exercise testing should be completed using the same physical activity that is performed during exercise training. The present study was designed to assess whether aerobic step exercisers have a greater maximal oxygen consumption (max VO sub 2) when tested using an activity specific, maximal step…

  19. Removal of Lipid from Serum Increases Coherence between Brucellosis Rapid Agglutination Test and Enzyme-linked Immunosorbent Assay in Bears in Alaska, USA.

    PubMed

    Godfroid, Jacques; Beckmen, Kimberlee; Helena Nymo, Ingebjørg

    2016-10-01

    In cases of chronic Brucella spp. infection, results of the rose bengal plate test (RBPT) and indirect enzyme-linked immunosorbent assay (ELISA) should be coherent, as reported in controlled conditions in the literature. We compared RBPT and ELISA results in 58 Alaska grizzly bears ( Ursus arctos horribilis), eight Kodiak brown bears ( Ursus arctos middendorffi), and six Alaska Peninsula brown bears ( Ursus arctos gyas). Of the 72 bears tested, 42 (58%) were ELISA positive and 53 (73%) were RBPT positive. However, the coherence between the tests was only fair (K=0.37, SE=0.11), suggesting that either the serologic results were not compatible with Brucella spp. infection or that there was a technical problem with the tests. To address a potential technical problem, we performed a 30-min chloroform/centrifugation cleanup. Following cleanup, the ELISA identified 43 positives (59%) and the RBPT identified 47 (65%), and the coherence between the tests was much improved (K=0.80, SE=0.07). We recommend cleaning wildlife sera with a high lipid content before performing RBPT and performing RBPT and ELISA in parallel to assess coherence. Our results suggest that Alaskan brown bears have been exposed to Brucella spp.

  20. Aeromonas hydrophila typing scheme based on patterns of agglutination with erythrocytes and yeast cells.

    PubMed Central

    Adams, D; Atkinson, H M; Woods, W H

    1983-01-01

    An agglutination typing scheme has been developed for strains of Aeromonas hydrophila. Primary agglutination typing is based on testing agar-grown A. hydrophila cells with human, horse, rat, and guinea pig erythrocytes and Saccharomyces cerevisiae cells. Further subdivision of primary groups is based firstly on whether yeast cell agglutination is inhibited by a D-mannose polymer, yeast mannan, and secondly on patterns of inhibition of hemagglutination by yeast mannan and the monomeric sugars L-fucose, D-galactose, and D-mannose. A total of 320 isolates were tested, and these were divisible into 39 distinct types on the basis of this scheme. Application of this typing scheme in the future to isolates of A. hydrophila known to be associated with human infection may enable correlations to be made between particular agglutination types and human pathogenicity. PMID:6841579

  1. Light-scattering analysis of ultrasonic wave's influence on the RBC agglutination in vitro

    NASA Astrophysics Data System (ADS)

    Doubrovski, Valeri A.; Dvoretski, Costanten N.

    1999-04-01

    Elastic light scattering is one of the most often used optical methods to analyze the cells agglutination reaction - the base of a great number of medical diagnostic test and biomedical investigations. The increase of the resolution of methods and apparatus towards the induced cells aggregation - the foundation of the reaction of agglutination, is quite an actual problem. The solution of this problem increases the reliability of the diagnostic test and gives an opportunity to achieve the diagnostic information in the cases when the traditional approaches do not lead to the diagnostic results. The attempt to increase the resolution of the immune reaction analyzer by means of ultrasonic waves action on the reagent mixture in vitro is taken in this paper. The RBC agglutination reaction which is usually used for the blood group type examination is chosen as an example of an object of the investigation. Different laser optical trains of the devices based on the turbidimetric and nephelometric methods and their combination are analyzed here. The influence of the ultrasonic wave time interval action and of the features of the sample preparation procedure on the resolution towards the agglutination process was investigated in this work. It is shown that the ultrasonic wave action on the reagent mixture leads to a large gain in the resolution of the device towards the RBC agglutination process. The experiments showed that the resolution of the device was enough to register the agglutination process even for the erythrocytes with weak agglutination ability when the reaction was invisible without ultrasonic action. It occurred that the diagnostic test time was more than by an order shortened due to the ultrasonic wave action. The optimal ultrasonic time interval action, the sample preparation technology and experimental technique were defined. The principle of the ultrasonic wave action on the cells agglutination process suggested here can be spread out on the immune

  2. Development of a peptide based latex agglutination assay for serotype identification of foot and mouth disease virus.

    PubMed

    Kaur, Dilpreet; Kaur, Gurpreet; Chandra, Mudit; Saxena, Hari M; Dwivedi, Padam N

    2013-02-01

    Out of 200 serum samples collected from cattle (142) and buffaloes (58) of various ages and sexand subjected to latex agglutination test (LAT) using serotype specific peptides (O, A, Asia 1) and also with peptide for non-structural protein 2B (NSP-2B), 114 (70%) samples were positive against FMDV type 'O', 102 (51%) against serotype 'A' and 104 (52%) against serotype 'Asia 1'. With NSP-2B peptide a total of 71 (35.5%) samples were positive. The results suggest that LAT could be used for the diagnosis of foot and mouth disease virus as it is easy, cheap and effective test.

  3. Agglutination by anti-capsular polysaccharide antibody is associated with protection against experimental human pneumococcal carriage

    PubMed Central

    Reiné, J; Zangari, T; Owugha, JT; Pennington, SH; Gritzfeld, JF; Wright, AD; Collins, AM; van Selm, S; de Jonge, MI; Gordon, SB; Weiser, JN; Ferreira, DM

    2016-01-01

    The ability of pneumococcal conjugate vaccine (PCV) to decrease transmission by blocking the acquisition of colonization has been attributed to herd immunity. We describe the role of mucosal IgG to capsular polysaccharide (CPS) in mediating protection from carriage, translating our findings from a murine model to humans. We used a flow-cytometric assay to quantify antibody-mediated agglutination demonstrating that hyperimmune sera generated against an unencapsulated mutant was poorly agglutinating. Passive immunization with this antiserum was ineffective to block acquisition of colonization compared to agglutinating antisera raised against the encapsulated parent strain. In the human challenge model samples were collected from PCV and control vaccinated adults. In PCV-vaccinated subjects IgG levels to CPS were increased in serum and nasal wash (NW). IgG to the inoculated strain CPS dropped in NW samples after inoculation suggesting its sequestration by colonizing pneumococci. In post-vaccination NW samples pneumococci were heavily agglutinated compared to pre-vaccination samples in subjects protected against carriage. Our results indicate that pneumococcal agglutination mediated by CPS specific antibodies is a key mechanism of protection against acquisition of carriage. Capsule may be the only vaccine target that can elicit strong agglutinating antibody responses, leading to protection against carriage acquisition and generation of herd immunity. PMID:27579859

  4. A particle agglutination assay for rapid identification of heparin binding to coagulase-negative staphylococci.

    PubMed

    Pascu, C; Hirmo, S; Ljungh, A; Wadström, T

    1996-10-01

    The heparin-binding properties of six different species of coagulase-negative staphylococci were examined by a particle agglutination assay. Heparin (mol. wt 4000-6000), mildly treated with sodium periodate, was covalently coupled to amino-modified latex beads (0.72 micron diameter). The particle agglutination assay was validated by comparing results with the adhesion (percentage binding of adherent cells) of coagulase-negative staphylococcal strains to heparinised microtitration plates. Of 38 different coagulase-negative staphylococcal strains tested, 30 showed agglutination reactivity with heparin-coated latex beads. Strains of different coagulase-negative staphylococcal species agglutinated heparin-coated latex beads to various extents (e.g., cells of Staphylococcus haemolyticus strains reacted more strongly than cells of S. epidermidis strains). The agglutination reaction was significantly inhibited by fucoidan, suramin, lambda-carrageenan and other sulphated compounds, but not by non-sulphated carbohydrate polymers such as hyaluronic acid. Agglutination of staphylococcal cells with heparin-coated latex beads was completely blocked by a cell-surface extract. These results suggest that structures responsible for heparin binding are exposed on the cell surface.

  5. Static testing and proposed standard specifications

    NASA Technical Reports Server (NTRS)

    Warner, E P

    1920-01-01

    Static tests fall into two groups, the first of which is designed to load all members of the structure approximately in accordance with the worst loads which they carry in flight, while the second is directed to the testing of specific members which are suspected of weakness and which are difficult to analyze mathematically. The nature of the loading in the second type is different for every different test, but the purpose of the first is defined clearly enough to permit the adoption of some standard set of loading specifications, at least for airplanes of normal design. Here, an attempt is made to carry through an analysis leading to such a standard, the goal being the determination of a load which will simultaneously impose on every member of the airplane structure a stress equal to the worst it will carry in flight.

  6. Are the Major Agglutinative Languages Genetically Related?

    ERIC Educational Resources Information Center

    Hakola, H. P. A.

    1989-01-01

    Examination of accidental CVC and CV correspondences among languages representing 5 large families of agglutinative languages found that comparison pairs had much more similarity between basic 100-word vocabularies than would have been possible by mere chance, supporting the hypothesis that those 5 language families were mutually related.…

  7. Process to create simulated lunar agglutinate particles

    NASA Technical Reports Server (NTRS)

    Gustafson, Robert J. (Inventor); Gustafson, Marty A. (Inventor); White, Brant C. (Inventor)

    2011-01-01

    A method of creating simulated agglutinate particles by applying a heat source sufficient to partially melt a raw material is provided. The raw material is preferably any lunar soil simulant, crushed mineral, mixture of crushed minerals, or similar material, and the heat source creates localized heating of the raw material.

  8. Testing of concurrent programs and partial specifications

    SciTech Connect

    Hamlet, D.

    1982-12-01

    The testing problems of concurrent systems include those of sequential programs, but there are two additional difficulties: the scheduling of tasks may alter the behavior, making tests misleading; testing may be conducted at an early stage of development, by users who are not software experts. Concurrent process systems can be modeled by a collection of finite-state transducers, in a way that displays their unique problems. The specification languages PAISLey and Gist approach the definition of concurrent systems differently, but both permit users to execute partially defined systems. The declarative language PROLOG, although not explicitly designed for concurrent programming, exhibits similar characteristics. Prototype execution has some unexpected implications for testing, and for final implementation.

  9. Slide Agglutination Method for the Serological Identification of Neisseria gonorrhoeae with Anti-Gonococcal Antibodies Adsorbed to Protein A-Containing Staphylococci

    PubMed Central

    Danielsson, Dan; Kronvall, Göran

    1974-01-01

    A rapid slide agglutination test has been developed for the identification of Neisseria gonorrhoeae that are primarily detected as oxidase-positive colonies in gonococcal cultures. The technique is based on the specific nonimmune reactivity between the Fc portion of immunoglobulin (Ig)G and staphylococcal protein A. IgG molecules adsorbed to stabilized staphylococci will thereby become oriented with their antigen-reactive sites that are directed outwards. Protein A-containing staphylococci with unabsorbed anti-gonococcal antibodies gave positive co-agglutination reactions with gonococci but also with meningococci, some Moraxella, Haemophilus, and Pseudomonas strains. These crossreactions were eliminated by absorption of the anti-gonococcal antiserum with meningococcal and Moraxella organisms prior to the coating of reagent staphylococci. In the routine culture diagnosis of N. gonorrhoeae the use of specific gonococcal reagent staphylococci gave concordant results with fermentation procedures and immunofluorescent techniques. Images PMID:4207280

  10. Tests in Print II: An Index to Tests, Test Reviews, and the Literature on Specific Tests.

    ERIC Educational Resources Information Center

    Buros, Oscar K., Ed.

    Tests in Print II is a comprehensive, annotated bibliography of all in-print tests published as separates for use with English-speaking subjects. The 1,155 two-column pages list 2,467 tests in print as of early 1974; 16,574 references through 1971 on specific tests; a reprinting of the 1974 APA-AERA-NCME Standards for Educational andPsychological…

  11. Extracellular calcium is involved in egg yolk-induced head-to-head agglutination of bull sperm.

    PubMed

    Yang, D H; McMillan, A G; Standley, N T; Shannon, P; Xu, Z Z

    2012-10-15

    Head-to-head agglutination of bull sperm occurs when semen is highly diluted in an egg yolk-citrate diluent without streptomycin. The objectives were to investigate causes of sperm agglutination and the underlying mechanism. Aliquots of bull semen were diluted in a base diluent (BD) supplemented with various test components and the percentage of agglutinated sperm (% AggSp) was quantified at 1, 5, 24, 48, and 72 h of incubation. When sperm were incubated at 22 °C, no agglutination was observed in BD for up to 72 h, whereas the % AggSp was 5.0, 41.7, 72.2, 91.1, and 92.8% in BD + 5% egg yolk (BD + EY) at 1, 5, 24, 48 and 72 h, respectively. However, no sperm agglutination was observed in BD + EY if incubation temperature was 37 °C. Addition of 5 or 10 mM ethylenebis (oxyethyleneni-trilo) tetra-acetic acid to BD + EY reduced the % AggSp from 95% to <5% at 72 h (P < 0.001), but addition of 5 mM CaCl(2) to BD failed to induce sperm agglutination in the absence of egg yolk, implicating calcium and other factors in egg yolk. Addition of the citrate-soluble fraction (CSF) of egg yolk to BD induced sperm agglutination similar to whole egg yolk, whereas water- and saline-soluble fractions of egg yolk were ineffective. The sperm-agglutinating efficacy of CSF (the % AggSp = 95% at 72 h) was reduced by dialysis (20%; P < 0.05), partially restored by addition of 5 mM CaCl2 (70%; P < 0.05), but the calcium effect was neutralized by addition of 5 mM ethylenebis (oxyethyleneni-trilo) tetra-acetic acid (1.7%; P < 0.05), again implicating calcium. Addition of 30 μM of a protein kinase A inhibitor (H-89) to an agglutinating diluent failed to inhibit sperm agglutination, whereas addition of 2 mM of a cAMP analogue, dbcAMP, to a nonagglutinating diluent failed to induce sperm agglutination. Agglutination status had no effect on sperm plasma membrane/acrosome status and mitochondrial membrane potential. In conclusion, calcium and other component(s) in the CSF of egg yolk induced head

  12. Formation of agglutinate-like particles in an experimental regolith

    NASA Technical Reports Server (NTRS)

    See, Thomas H.; Horz, Friedrich

    1988-01-01

    Agglutinate-like particles composed predominantly of glass were produced from a fragmental gabbro target that was repetitively impacted by Ni-alloy projectiles. The experimental glasses are much more heterogeneous in composition than their lunar counterparts, and they are dominated by incomplete mixing of melted component minerals and by plagioclase-rich compositions. Most of the particles are found to be highly enriched in feldspar and to be sustantially fractionated relative to the initial bulk target. It is suggested that fractionation trends within lunar agglutinitic glasses may be partly due to phase-specific melting.

  13. [Diagnosis of some yeasts in Metschnikowia genus with the aid of Salmonella cholerae-suis O agglutinating serum (author's transl)].

    PubMed

    Aksoycan, N

    1980-04-01

    In this paper a common antigenic factor among Salmonella choleraesuis 0 antigen and standard Metschnikowia bicuspidata var. bicuspidata and M. pulcherrima strains is shown. This common factor was not present in M. bicuspidata var. australis, M. bicuspidata var. california, M. krissii and M. reukaufii strains. M. bicuspidata var. chathamia and M. zobellii showed agglutination in the previous experiments. According to these results, the use of S. choleraesuis 0:6,7 agglutinating serum for slide and tube agglutination tests can be a diagnostic aid for typing above mentioned Metschnikowia strains along with the other tests.

  14. [Methicillin resistance detection in Staphylococcus aureus: comparison between conventional methods and MRSA-Screen latex agglutination technique].

    PubMed

    Soloaga, R; Corso, A; Gagetti, P; Faccone, D; Galas, M

    2004-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a significant pathogen that has emerged over the last four decades, causing both nosocomial and community-acquired infections. Rapid and accurate detection of methicillin resistance in S. aureus is important for the use of appropriate antimicrobial therapy and for the control of nosocomial spread of MRSA strains. We evaluated the efficiency of conventional methods for detection of methicillin resistance such as the disk diffusion, agar dilution, oxacillin agar screen test, and the latex agglutination test MRSA-Screen latex, in 100 isolates of S. aureus, 79 mecA positive and 21 mecA negative. The MRSA-Screen latex (Denka Seiken, Niigata, Japón), is a latex agglutination method that detects the presence of PLP-2a, product of mecA gene in S. aureus. The PCR of the mecA gene was used as the "gold standard" for the evaluation of the different methods tested. The percentages of sensitivity and specificity were as follows: disk difusión 97 and 100%, agar dilution 97 and 95%, oxacillin agar screen test 100 and 100%, and MRSA-Screen latex, 100 and 100 %. All methods presented high sensitivity and specificity, but MRSA-Screen latex had the advantage of giving a reliable result, equivalent to PCR, in only 15 minutes.

  15. Development of a slide agglutination assay for detection of blastomycosis.

    PubMed

    Hatch, Wayne O; Scalarone, Gene M

    2013-11-01

    Blastomycosis, caused by the thermally dimorphic fungus Blastomyces dermatitides, which is endemic to eastern regions of the USA, is commonly misdiagnosed as a viral or bacterial infection and therefore treated improperly. Over the years, many immunodiagnostic assays to aid in the diagnosis of blastomycosis have been developed; however, a reliable assay for use in local clinics still remains elusive. Procedures for a slide agglutination assay for detection of antibody in serum from rabbits immunized with B. dermatitidis were evaluated with antigenic preparations from B. dermatitidis adsorbed to polystyrene microparticles. Yeast-phase lysates from five isolates of B. dermatitides: namely ER-593 (Eagle River, WI, USA), ER-598 (Eagle River, WI, USA), 48938 (India), B5896 (Mt. Iron, MN, USA), and T-58 (TN, USA) were evaluated for their sensitivity and specificity. Sensitivities of the lysates ranged from 29% to 83% whereas specificities ranged from 13% to 100%. Lysate ER-593 provided the most promising results with a sensitivity of 82% and specificity of 100%. This study provides suggests that a simple rapid slide agglutination assay for detecting blastomycosis may be used for screening patients with suspected B. dermatitidis infection.

  16. [Identification of mosquitoes' human food source by using the co-agglutination technique].

    PubMed

    Castex, M; Fachado, A; Fonte, L

    1997-01-01

    The utilization of a coagglutination technique for the identification of a human source for feeding mosquitoes is described. The dilution of ingested blood samples in filter paper was performed in 2 mL of a sodium chloride solution at 0.85%. It was used a suspension of sensibilized Staphylococcus aureus with rabbit's serum, human plasmatic anti-proteins, and human anti-IgG rabbit's serum discriminated well between human and non human blood. No agglutination was observed with the negative control. This technique proved to be sensitive to identify 100% of the human blood samples taken to the paper 24 hours after the mosquitoes completed their feeding at a temperature of 26 to 28 degrees C. Among mosquitoes fed and collected in the fields the test had a satisfactory result. Therefore, it may be used in routine work in the fields. The results showed the sensitivity and specificity of this method for identifying human blood ingested by mosquitoes.

  17. The interaction of antigen and antibody in agglutination

    PubMed Central

    Elek, S. D.; Smith, B. V. Kingsley; Highman, Wilma

    1964-01-01

    Flagellar fragments are thin cylinders that are particularly suitable for the study of agglutination by electron microscopy. Their shape leads to a characteristic pattern of agglutination and thus the early stages can be studied. Measurement of interflagellar distances under conditions of negative staining, suggest that the minimum length of the rabbit antibody molecules is about 180 Å. The molecules carry the specific sites at the ends of the long axis, and become attached radially to the surface of the flagella, resembling the bristles of a bottle-brush. To explain this orientation it is postulated that the antibody is inserted into the surface of the flagellum in such a manner that surrounding molecules give it a fixed direction. Geometrically this hypothesis corresponds to an insertion into pits. Pepsin-treated (5S) rabbit antibody behaves in a like manner, but the molecule appears to be shorter. No information could be obtained about the thickness and actual shape of antibody molecules by the techniques employed. ImagesFIG. 1FIG. 2FIG. 3FIG. 4FIG. 5FIG. 6FIG. 9FIG. 11FIG. 13FIG. 14FIG. 15 PMID:14210767

  18. 21 CFR 660.54 - Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... heterospecific antibodies, and additional tests for nonspecific properties. 660.54 Section 660.54 Food and Drugs..., specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties. The...) Specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties....

  19. 21 CFR 660.54 - Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... heterospecific antibodies, and additional tests for nonspecific properties. 660.54 Section 660.54 Food and Drugs..., specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties. The...) Specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties....

  20. 21 CFR 660.54 - Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... heterospecific antibodies, and additional tests for nonspecific properties. 660.54 Section 660.54 Food and Drugs..., specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties. The...) Specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties....

  1. 21 CFR 660.54 - Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... heterospecific antibodies, and additional tests for nonspecific properties. 660.54 Section 660.54 Food and Drugs..., specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties. The...) Specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties....

  2. 21 CFR 660.54 - Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... heterospecific antibodies, and additional tests for nonspecific properties. 660.54 Section 660.54 Food and Drugs..., specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties. The...) Specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties....

  3. Ultrasensitive Antibody Detection by Agglutination-PCR (ADAP)

    PubMed Central

    2016-01-01

    Antibodies are widely used biomarkers for the diagnosis of many diseases. Assays based on solid-phase immobilization of antigens comprise the majority of clinical platforms for antibody detection, but can be undermined by antigen denaturation and epitope masking. These technological hurdles are especially troublesome in detecting antibodies that bind nonlinear or conformational epitopes, such as anti-insulin antibodies in type 1 diabetes patients and anti-thyroglobulin antibodies associated with thyroid cancers. Radioimmunoassay remains the gold standard for these challenging antibody biomarkers, but the limited multiplexability and reliance on hazardous radioactive reagents have prevented their use outside specialized testing facilities. Here we present an ultrasensitive solution-phase method for detecting antibodies, termed antibody detection by agglutination-PCR (ADAP). Antibodies bind to and agglutinate synthetic antigen–DNA conjugates, enabling ligation of the DNA strands and subsequent quantification by qPCR. ADAP detects zepto- to attomoles of antibodies in 2 μL of sample with a dynamic range spanning 5–6 orders of magnitude. Using ADAP, we detected anti-thyroglobulin autoantibodies from human patient plasma with a 1000-fold increased sensitivity over an FDA-approved radioimmunoassay. Finally, we demonstrate the multiplexability of ADAP by simultaneously detecting multiple antibodies in one experiment. ADAP’s combination of simplicity, sensitivity, broad dynamic range, multiplexability, and use of standard PCR protocols creates new opportunities for the discovery and detection of antibody biomarkers. PMID:27064772

  4. The chemistry of some individual lunar soil agglutinates

    NASA Technical Reports Server (NTRS)

    Gibbons, R. V.; Hoerz, F.; Schaal, R. B.

    1976-01-01

    The inquiry is centered on the composition of agglutinate glasses examined via microprobe techniques. The glass chemistry of the agglutinates is brought into relation with compositions of constituent detritus and bulk compositions of the parent soils, with recent reported results taken into cognizance. Electron microprobe analysis data were examined for possible chemical fractionation resulting from meteoritic impacts and formation of agglutinates in the lunar regolith; individual agglutinates from lunar soils 78222, 71061, and 60009 were probed. Differences between impact glasses and corresponding bulk soils were scrutinized. Agglutinate glass analyses tend to cluster near the bulk soil compositions. A slight enrichment in mafic elements in grand averages of the agglutinate clusters relative to the bulk soils was found. Evidence of total impact melts and minor partial shock melts is examined.

  5. Mass-based readout for agglutination assays

    NASA Astrophysics Data System (ADS)

    Chunara, Rumi; Godin, Michel; Knudsen, Scott M.; Manalis, Scott R.

    2007-11-01

    We present a mass-based readout for agglutination assays. The suspended microchannel resonator (SMR) is used to classify monomers and dimers that are formed during early stage aggregation, and to relate the total count to the analyte concentration. Using a model system of streptavidin functionalized microspheres and biotinylated antibody as the analyte, we obtain a dose-response curve over a concentration range of 0.63-630nM and show that the results are comparable to what has been previously achieved by image analysis and conventional flow cytometry.

  6. Nitrogen isotopic signatures in agglutinates from breccia 79035

    NASA Technical Reports Server (NTRS)

    Kerridge, John F.; Kim, Yoosook; Kim, Jin S.; Marti, Kurt

    1993-01-01

    Agglutinates in the size range 125-175 microns from regolith breccia 79035 are substantially depleted in N compared with bulk 79035. Isotopically, agglutinate N closely resembles that found previously in ilmenite separates. The minimum (delta)N-15 value found during stepwise pyrolysis of agglutinates is significantly heavier than that observed for bulk 79035. The major host phase for trapped N in 79035, and the host phase of the lightest isotopic component(s), remain unidentified.

  7. The Classroom-Friendly ABO Blood Types Kit: Blood Agglutination Simulation

    ERIC Educational Resources Information Center

    Arnold, Savittree Rochanasmita; Kruatong, Tussatrin; Dahsah, Chanyah; Suwanjinda, Duongdearn

    2012-01-01

    The classroom-friendly ABO blood type kit was developed by combining advantages of modelling and a simulation laboratory to teach the topics of ABO blood types and blood transfusion. Teachers can easily simulate the agglutination reaction on a blood type testing plate in the classroom, and show the students how this reaction occurs by using the…

  8. 7 CFR 51.3417 - Optional test for specific gravity.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Optional test for specific gravity. 51.3417 Section 51... § 51.3417 Optional test for specific gravity. Tests to determine specific gravity shall be made in... lot with respect to size and quality. The specific gravity for any lot of potatoes shall be...

  9. 7 CFR 51.3417 - Optional test for specific gravity.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Optional test for specific gravity. 51.3417 Section 51... § 51.3417 Optional test for specific gravity. Tests to determine specific gravity shall be made in... lot with respect to size and quality. The specific gravity for any lot of potatoes shall be...

  10. D-penicillamine prevents ram sperm agglutination by reducing the disulphide bonds of a copper-binding sperm protein.

    PubMed

    Leahy, T; Rickard, J P; Aitken, R J; de Graaf, S P

    2016-05-01

    Head-to-head agglutination of ram spermatozoa is induced by dilution in the Tyrode's capacitation medium with albumin, lactate and pyruvate (TALP) and ameliorated by the addition of the thiol d-penicillamine (PEN). To better understand the association and disassociation of ram spermatozoa, we investigated the mechanism of action of PEN in perturbing sperm agglutination. PEN acts as a chelator of heavy metals, an antioxidant and a reducing agent. Chelation is not the main mechanism of action, as the broad-spectrum chelator ethylenediaminetetraacetic acid and the copper-specific chelator bathocuproinedisulfonic acid were inferior anti-agglutination agents compared with PEN. Oxidative stress is also an unlikely mechanism of sperm association, as PEN was significantly more effective in ameliorating agglutination than the antioxidants superoxide dismutase, ascorbic acid, α-tocopherol and catalase. Only the reducing agents cysteine and DL-dithiothreitol displayed similar levels of non-agglutinated spermatozoa at 0 h compared with PEN but were less effective after 3 h of incubation (37 °C). The addition of 10 µM Cu(2+) to 250 µM PEN + TALP caused a rapid reversion of the motile sperm population from a non-agglutinated state to an agglutinated state. Other heavy metals (cobalt, iron, manganese and zinc) did not provoke such a strong response. Together, these results indicate that PEN prevents sperm association by the reduction of disulphide bonds on a sperm membrane protein that binds copper. ADAM proteins are possible candidates, as targeted inhibition of the metalloproteinase domain significantly increased the percentage of motile, non-agglutinated spermatozoa (52.0% ± 7.8) compared with TALP alone (10.6% ± 6.1).

  11. Single Event Testing on Complex Devices: Test Like You Fly versus Test-Specific Design Structures

    NASA Technical Reports Server (NTRS)

    Berg, Melanie; LaBel, Kenneth A.

    2014-01-01

    We present a framework for evaluating complex digital systems targeted for harsh radiation environments such as space. Focus is limited to analyzing the single event upset (SEU) susceptibility of designs implemented inside Field Programmable Gate Array (FPGA) devices. Tradeoffs are provided between application-specific versus test-specific test structures.

  12. CLAD/BCLAD Examinations. Test Specifications.

    ERIC Educational Resources Information Center

    California Commission on Teacher Credentialing, Sacramento.

    This draft handbook provides descriptions and summaries of the six tests that California elementary and secondary teachers must pass to earn the Crosscultural, Language, and Academic Development (CLAD) or Bilingual, Crosscultural, Language, and Academic Development (BCLAD) certificates. The six tests include: (1) "Language Structure and…

  13. Draft Test Guideline: Site-Specific Aquatic Microcosm Test, Laboratory

    EPA Pesticide Factsheets

    The following draft test guideline is part of a series of test guidelines that have been developed by EPA for use in the testing of pesticides and toxic substances, and the development of test data for submission to the Agency for review.

  14. Systems, devices, and methods for agglutination assays using sedimentation

    DOEpatents

    Schaff, Ulrich Y.; Sommer, Gregory J.; Singh, Anup K.

    2016-01-26

    Embodiments of the present invention include methods for conducting agglutination assays using sedimentation. Aggregates may be exposed to sedimentation forces and travel through a density medium to a detection area. Microfluidic devices, such as microfluidic disks, are described for conducting the agglutination assays, as are systems for conducting the assays.

  15. Prostate-Specific Antigen (PSA) Test

    MedlinePlus

    ... prostate cancer recurrence. However, a single elevated PSA measurement in a patient who has a history of ... than with BPH . One recently approved test combines measurement of a form of pro-PSA called [-2] ...

  16. 7 CFR 51.3417 - Optional test for specific gravity.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Optional test for specific gravity. 51.3417 Section 51... specific gravity. Tests to determine specific gravity shall be made in accordance with the procedures set.... The specific gravity for any lot of potatoes shall be the average of at least 3 corrected readings...

  17. 7 CFR 51.3417 - Optional test for specific gravity.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Optional test for specific gravity. 51.3417 Section 51... specific gravity. Tests to determine specific gravity shall be made in accordance with the procedures set.... The specific gravity for any lot of potatoes shall be the average of at least 3 corrected readings...

  18. 7 CFR 51.3417 - Optional test for specific gravity.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Optional test for specific gravity. 51.3417 Section 51... specific gravity. Tests to determine specific gravity shall be made in accordance with the procedures set.... The specific gravity for any lot of potatoes shall be the average of at least 3 corrected readings...

  19. Gelatin particle indirect agglutination and enzyme-linked immunosorbent assay for diagnosis of strongyloidiasis using Strongyloides venezuelensis antigen.

    PubMed

    Huaman, Maria Cecilia; Sato, Yoshiya; Aguilar, Jose Luis; Terashima, Angelica; Guerra, Humberto; Gotuzzo, Eduardo; Kanbara, Hiroji

    2003-01-01

    Routine microscopical examination of stool specimens for diagnosis of strongyloidiasis is insensitive and serological methods using Strongyloides stercoralis antigen are at present not available for field studies. We evaluated 2 techniques, enzyme-linked immunosorbent assay (ELISA) and gelatin particle indirect agglutination (GPIA), using an antigen obtained from the rodent parasite, S. venezuelensis. Fifty-four Peruvian patients with different clinical forms of strongyloidiasis were studied: 12 asymptomatic, 31 symptomatic, and 11 hyperinfection cases. Our results demonstrate that both ELISA and GPIA using S. venezuelensis antigen are useful for diagnosis of strongyloidiasis, with sensitivities of 74.1% and 98.2%, respectively and a specificity of 100% for both techniques. We found that GPIA is a highly sensitive test for patients with suspected chronic infection and/or hyperinfection. In the hyperinfection cases, significantly lower concentrations of specific immunoglobulin antibodies and eosinophils (P < 0.001) were found compared with the asymptomatic and symptomatic cases.

  20. Prevention of nonspecific reactions on reversed passive latex agglutination assay (RPLA) for detecting low amounts of staphylococcal enterotoxins.

    PubMed

    Pereira, M L; Heneine, L G; Santos, E J; Carmo, L S; Pereira, J L; Bergdoll, M S

    1997-01-01

    The SET-RPLA, from Denka Seiken Co. Ltd., Tokio, a commercial reversed passive latex agglutination test kit, has been recommended to establish the enterotoxicity capacity of some staphylococcal strains, implicated in food poisoning outbreaks that produce low levels of enterotoxins (SE). Despite the RPLA specificity, the occurrence of nonspecific reactions when testing low-SE-producing is common. In order to control these nonspecific reactions the addition of purified normal rabbit IgG purified was applied on approximately 350 staphylococcal isolates from human milk and anatomic sites of healthy dental student carriers. The results indicated that addition of 5% (v/v) of purified normal rabbit IgG (0.74 mg/mL) to the culture supernatant fluid is a simple and reliable tool for the controlling of nonspecific reactions in the RPLA assay.

  1. Enhancement of Leptospira hardjo agglutination titers in sheep and goat serum by heat inactivation.

    PubMed

    Malkin, K

    1984-04-01

    Heat inactivation of sheep serum samples resulted in the detection of an additional 9% reactors to Leptospira hardjo that were negative on the initial test of fresh samples. Treatment with EDTA gave results generally similar to heat inactivation suggesting that complement was responsible for the inhibition of agglutination. Tests on heat inactivated serum from experimentally infected sheep and goats revealed enhanced titers or reactions which were not detected in fresh serum.

  2. High Bacterial Agglutination Activity in a Single-CRD C-Type Lectin from Spodoptera exigua (Lepidoptera: Noctuidae)

    PubMed Central

    Gasmi, Leila; Ferré, Juan; Herrero, Salvador

    2017-01-01

    Lectins are carbohydrate-interacting proteins that play a pivotal role in multiple physiological and developmental aspects of all organisms. They can specifically interact with different bacterial and viral pathogens through carbohydrate-recognition domains (CRD). In addition, lectins are also of biotechnological interest because of their potential use as biosensors for capturing and identifying bacterial species. In this work, three C-type lectins from the Lepidoptera Spodoptera exigua were produced as recombinant proteins and their bacterial agglutination properties were characterized. The lowest protein concentration producing bacterial agglutination against a panel of different Gram+ and Gram− as well as their carbohydrate binding specificities was determined for the three lectins. One of these lectins, BLL2, was able to agglutinate cells from a broad range of bacterial species at an extremely low concentration, becoming a very interesting protein to be used as a biosensor or for other biotechnological applications involving bacterial capture. PMID:28257054

  3. High Bacterial Agglutination Activity in a Single-CRD C-Type Lectin from Spodoptera exigua (Lepidoptera: Noctuidae).

    PubMed

    Gasmi, Leila; Ferré, Juan; Herrero, Salvador

    2017-03-01

    Lectins are carbohydrate-interacting proteins that play a pivotal role in multiple physiological and developmental aspects of all organisms. They can specifically interact with different bacterial and viral pathogens through carbohydrate-recognition domains (CRD). In addition, lectins are also of biotechnological interest because of their potential use as biosensors for capturing and identifying bacterial species. In this work, three C-type lectins from the Lepidoptera Spodoptera exigua were produced as recombinant proteins and their bacterial agglutination properties were characterized. The lowest protein concentration producing bacterial agglutination against a panel of different Gram+ and Gram- as well as their carbohydrate binding specificities was determined for the three lectins. One of these lectins, BLL2, was able to agglutinate cells from a broad range of bacterial species at an extremely low concentration, becoming a very interesting protein to be used as a biosensor or for other biotechnological applications involving bacterial capture.

  4. A new LDLa domain-containing C-type lectin with bacterial agglutinating and binding activity in amphioxus.

    PubMed

    Qu, Baozhen; Yang, Shuangshuang; Ma, Zengyu; Gao, Zhan; Zhang, Shicui

    2016-12-15

    Over 1200 C-type lectin gene models have been identified in amphioxus, but only a few of them have been functionally characterized. In this study, we identified a C-type lectin, BjCTL, with domain structure of LDLa-CTLD-EGF_Lam, the first such data in chordates. It was expressed mainly in the notochord and ovary in a tissue-dependent fashion. Recombinant BjCTL was characterized as a typical Ca(2+)-dependent carbohydrate-binding protein capable of agglutinating and binding to both Gram-negative and positive bacteria we tested. In addition, it specifically bound to insoluble lipopolysaccharide, lipoteichoic acid and peptidoglycan, which can be inhibited by galactose. We also showed that the interaction of BjCTL with the bacteria is primarily attributable to CTLD domain. Thus, BjCTL is a novel pattern recognition protein involved in lectin-mediated innate immunity.

  5. High Voltage Testing. Volume 2. Specifications and Test Procedures

    DTIC Science & Technology

    1982-08-01

    as tested to 4.7.12 shall exhibit no evidence of mechanical damage. 103 °o. . .. 3.16 Salt spray (corrosion) (metal surfaces only, see 3.1). When...of the surfaces shall be affected by flaking, peeling, or blistering of paint. There shall be no evidence of unwrapping of or mechanical damage to...Profile 48 A6 Typical Mechanical Release Fixture 50 A7 Suggested Method for Making Cable Ends Corona Free 56 BI Solder Contact (Pin and Socket

  6. Agglutination of human erythrocytes by the interaction of Zn(2+)ion with histidine-651 on the extracellular domain of band 3.

    PubMed

    Kiyotake, Kento; Ochiai, Hideharu; Yamaguchi, Takeo

    2016-05-01

    Clustering of band 3, chloride/bicarbonate exchanger, has been reported in Zn(2+)-treated human erythrocytes. However, the agglutination of human erythrocytes is also induced by the interaction of Zn(2+)ion with histidine on band 3. Identification of histidine that interacts with Zn(2+)ion remains to be determined. The Zn(2+)-induced agglutination of human erythrocytes was unaffected by chymotrypsin cleavage of the small loop region containing His-547 in the extracellular domain of band 3. On the other hand, papain digestion of the large loop region containing His-651 in band 3 inhibited such Zn(2+)-induced agglutination. Moreover, Zn(2+)-induced erythrocyte agglutination was inhibited by the peptide (ARGWVIHPLG) containing His-651, but not by the peptide such as ARGWVIRPLG, which His-651 was substituted by arginine. Among 10 kinds of animal erythrocytes tested, interestingly, no agglutination by Zn(2+)ions was observed in cow cells only that the forth amino acid in the upstream from His-669 on the large loop of cow band 3 is aspartate (Asp-665) instead of glycine. As expected, the agglutination of human erythrocytes by Zn(2+) ions was inhibited in the presence of aspartate. These data indicate that the interaction of Zn(2+) ion with His-651 residue of band 3 plays an important role in the Zn(2+)-induced agglutination of human erythrocytes.

  7. Development of a Program Specific Locator Test. Final Report.

    ERIC Educational Resources Information Center

    Benn, Robert J.

    A project was undertaken to develop a series of program-specific vocational locator tests (PSVLTs) that would consist of subject-specific questions in three academic disciplines--writing, reading, and mathematics--for use in predicting vocational students' success in their vocational programs. As a prelude to constructing the tests, project staff…

  8. 46 CFR 189.20-20 - Specific tests and inspections.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Specific tests and inspections. 189.20-20 Section 189.20-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS INSPECTION AND CERTIFICATION Initial Inspection § 189.20-20 Specific tests and inspections. The...

  9. 46 CFR 189.20-20 - Specific tests and inspections.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Specific tests and inspections. 189.20-20 Section 189.20-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS INSPECTION AND CERTIFICATION Initial Inspection § 189.20-20 Specific tests and inspections. The...

  10. Test specification for decant pump and winch assembly. Revision 2

    SciTech Connect

    Staehr, T.W.

    1995-02-22

    This specification provides the requirements for testing of the vertical turbine decant pump including the floating suction with load sensing winch control, instrumentation and the associated PLC/PC control system. All assembly necessary for testing including piping, temporary wiring, etc., shall be performed by the Seller. All referenced figures are at the back of this document. The testing consists of performance testing, winch testing and calibration, instrumentation verification testing and run-in testing of the pump. Testing shall be done in the presence and under the direction of the Buyer in accordance with this procedure.

  11. Comparison of agglutinating and neutralizing antibodies to serovar hardjo in sows immunized with two commercial whole culture polivalent anti-leptospira bacterins

    PubMed Central

    Soto, Francisco Rafael Martins; Pinheiro, Sônia Regina; Morais, Zenaide Maria; Gonçales, Amane Paldês; de Azevedo, Sérgio Santos; Bernardi, Fernanda; Camargo, Sebastião Rodrigues; Vasconcellos, Silvio Arruda

    2008-01-01

    It was performed the comparison of the intensity and duration of agglutinating and neutralizing antibodies to serovar Hardjo in swines vaccinated with two commercial anti-leptospira bacterins. Sows no reactive to 24 Leptospira sp serovars in the microscopic agglutination test (MAT) were divided in three groups: Group A (n=08): received two vaccine A doses with 30 days interval, Group B (n=08) two vaccine B doses with 30 days interval and Group C (n=08): control no vaccinated against leptospirosis.Blood samples were collected each 30 days during six months following the first vaccination. The sera were tested by MAT and growth inhibition test (GIT) to serovar Hardjo in order to evaluate respectively agglutinating and neutralizing antibodies. It was found that neutralizing antibodies persisted for a longer time than the agglutinating ones and that the absence of agglutinating antibodies does not means in the absence of the neutralizing. The peaks of agglutinating antibodies was obtained at least 30 days earlier than that produced by neutralizing. The duration of both kinds of antibodies measured differed between the two bacterines tested. The period for inducing neutralizing antibodies against serovar Hardjo indicated that gilts must be immunized with two doses of whole culture anti-leptospira bacterines applied 30 days each other at least 90 days before the first mating. For the maintenance of hight levels of neutralizing antibodies the revaccinations must be performed every six months after the first vaccination. PMID:24031250

  12. A Ratio Test of Interrater Agreement with High Specificity

    ERIC Educational Resources Information Center

    Cousineau, Denis; Laurencelle, Louis

    2015-01-01

    Existing tests of interrater agreements have high statistical power; however, they lack specificity. If the ratings of the two raters do not show agreement but are not random, the current tests, some of which are based on Cohen's kappa, will often reject the null hypothesis, leading to the wrong conclusion that agreement is present. A new test of…

  13. The BITCH-100: A Culture-Specific Test

    ERIC Educational Resources Information Center

    Williams, Robert L.

    1975-01-01

    A description of the rationale and the development of the BITCH-100 (Black Intelligence Test of Cultural Homogeneity), a culture specific test for the American black population. Experimental evidence is reported on the norming and validation of this instrument and suggestions made as to potential advantages over the traditional testing approach as…

  14. Introduction to Psychology and Leadership. Specifications of Research Test Items.

    ERIC Educational Resources Information Center

    Shrage, Jules H.; And Others

    The working guidelines for the development of research test items for the cumulative post-tests of the United States Naval Academy's leadership course developed by the Westinghouse Learning Corporation are presented in this report, including general specifications, content analysis and test construction, and classification of items. EM 010 418…

  15. Momordica charantia seed lectin: toxicity, bacterial agglutination and antitumor properties.

    PubMed

    Kabir, Syed Rashel; Nabi, Md Mahamodun; Nurujjaman, Md; Abu Reza, Md; Alam, A H M Khurshid; Uz Zaman, Rokon; Khalid-Bin-Ferdaus, Khandaker Md; Amin, Ruhul; Khan, Md Masudul Hasan; Hossain, Md Anowar; Uddin, Md Salim; Mahmud, Zahid Hayat

    2015-03-01

    In last three decades, several studies were carried out on the D-galactose-specific lectin of Momordica charantia seeds (MCL). In the present study, in vitro growth inhibition (8-23 %) at different concentrations (6-24 μg/ml) of MCL was observed against Ehrlich ascites carcinoma (EAC) cells by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. MCL also showed 28, 45, and 75 % growth inhibitions against EAC cells when administered 1.2, 2.0, and 2.8 mg/kg/day (i.p.), respectively for five consequent days in vivo in mice. After lectin treatment, the level of red blood cell and hemoglobin was increased significantly with the decrease of white blood cell and maintained the normal level when compared with EAC-bearing control and normal mice without EAC cells. Although MCL caused cell cycle arrest at G0/G1 phase of EAC cells, any irregular shape or apoptotic morphological alterations in the lectin-treated EAC cells was not observed by an optical and fluorescence microscope. Lectin showed toxicity against brine shrimp nauplii with an LC50 value of 49.7 μg/ml. Four out of seven pathogenic bacteria were agglutinated by MCL in the absence of inhibitory sugar D-lactose/D-galactose. In conclusion, MCL showed strong cytotoxic effect and therefore can be used as a potent anticancer chemotherapeutic agent.

  16. R and G color component competition of RGB image decomposition as a criterion to register RBC agglutinates for blood group typing.

    PubMed

    Doubrovski, Valeri A; Ganilova, Yuliya A; Zabenkov, Igor V

    2014-03-01

    A new approach of the criterion assignment for registration of erythrocyte agglutinates to instrumentally determine blood group type is suggested. The criterion is based on comparison of R and G components of RGB decomposition of microscopy digital image taken for the blood-serum mixture sample. For the chosen experimental conditions, the minimal size (area) of RBC agglutinate to be registered by the criterion suggested is estimated theoretically. The proposed method was tested experimentally on the example of monitoring agglutinates in flow. The encouraging experimental results were obtained for improvement of the resolving power of the method; the optimal experimental conditions were revealed for maximum resolution. Though the suggested method was realized for dynamic (flow) blood group determination, it could also be applied for diagnostics in a stationary environment. This approach increases the reliability of RBC agglutinates registration and, hence, blood group typing. The results may be used to develop the apparatus for automated determination of human blood group.

  17. Test specification for decant pump and winch assembly

    SciTech Connect

    Staehr, T.W.

    1994-12-07

    This specification provides the requirements for testing of the vertical turbine decant pump including the floating suction arm with load sensing winch control, instrumentation and the associated PLC/PC control system.

  18. Sensitivity and specificity of rapid diagnostic tests for detection of group B streptococcal antigen in bacteremic neonates.

    PubMed Central

    Greenberg, D N; Ascher, D P; Yoder, B A; Hensley, D M; Heiman, H S; Keith, J F

    1995-01-01

    Latex particle agglutination (LPA) testing for antigen to group B streptococcus (GBS) has been useful in the diagnosis of GBS sepsis in newborns. However, recent reports have demonstrated that the sensitivity of LPA assays may be as low as 27 to 54%. The purposes of the present study were to directly compare the abilities of four urine antigen assays to detect GBS antigen with clinical urine samples from neonates with GBS bacteremia and to evaluate the effect of the urine concentration on the sensitivities and specificities of these assays. Urine samples were collected serially from neonates with blood cultures positive for GBS or on admission from healthy full-term infants. One milliliter of urine was removed, and the remainder was concentrated to a volume of 1 ml. Unconcentrated samples were serially diluted with normal saline and were assayed to determine the highest dilution which would produce a positive test result. The Wellcogen, Bactigen, and Directigen LPA tests and ICON immunoassay were directly compared by using concentrated and unconcentrated urine specimens and urine specimens with known titers. A total of 94 urine specimens, including 61 concentrated and 75 unconcentrated specimens, from bacteremic infants were available for sensitivity testing, and 220 urine specimens from uninfected infants were available for specificity testing. There were significant differences in sensitivity among the four assays when they were performed on concentrated urine specimens, as follows: Directigen, 98%; Bactigen, 92%; ICON, 89%; Wellcogen, 68%. When the assays were performed on unconcentrated urine specimens, the Directigen (84%) and Bactigen (76%) assays were each significantly more sensitive than the ICON (59%) or Wellcogen (43%) assay.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7699040

  19. The BITCH-100: A Culture-Specific Test.

    ERIC Educational Resources Information Center

    Williams, Robert L.

    The aim of this paper is to describe the rationale and evaluation of the Black Intelligence Scale of Cultural Homogeneity (BITCH). A "culture specific" test is used to determine the taker's ability to function symbolically or to think in terms of his own culture and environment. A combination of dialect specific and culture specific…

  20. Consistency test for simple specifications of automation systems

    SciTech Connect

    Chebotarev, A.N.

    1995-01-01

    This article continues the topic of functional synthesis of automaton systems for discrete-information processing. A language of functional specification of automaton systems based on the logic of one-place predicates of an integer argument has been described. A specification in this language defines a nondeterministic superword X-Y-function, i.e., a function that maps superwords in the alphabet X into sets of superwords in the alphabet Y (the alphabets X and Y are specification-dependent), which corresponds to an initialized nondeterministic X-Y-automaton. The specification G is consistent if the function defined by the specification corresponds to an automaton A{sub G} with a nonempty state set. Consistency tests for the initial specification and for various intermediate specifications obtained in the process of functional synthesis of the automaton system are of fundamental importance for the verificational method of automaton system design developed in the framework of the proposed topic. We need sufficiently efficient algorithms to test consistency of specifications. An algorithm proposal constructs the coresponding automaton A{sub G} for any simple specifications G. The consistency of a specification is thus decided constructively. However, this solution is not always convenient, because it usually involves a highly time-consuming procedure to construct a nondeterministic automaton with a very large number of states. In this paper, we propose a convenient approach that combines automaton and logic methods and established consistency or inconsistency of a specification without constructing the corresponding autmaton.

  1. Simplified spectraphotometric method for the detection of red blood cell agglutination.

    PubMed

    Ramasubramanian, Melur; Anthony, Steven; Lambert, Jeremy

    2008-08-01

    Human error is the most significant factor attributed to incompatible blood transfusions. A spectrophotometric approach to blood typing has been developed by examining the spectral slopes of dilute red blood cell (RBC) suspensions in saline, in the presence and absence of various antibodies, offering a technique for the quantitative determination of agglutination intensity [Transfusion39, 1051, 1999TRANAT0041-113210.1046/j.1537-2995.1999.39101051.x]. We offer direct theoretical prediction of the observed change in slope in the 660-1000 nm range through the use of the T-matrix approach and Lorenz-Mie theory for light scattering by dilute RBC suspensions. Following a numerical simulation using the T-matrix code, we present a simplified sensing method for detecting agglutination. The sensor design has been prototyped, fully characterized, and evaluated through a complete set of tests with over 60 RBC samples and compared with the full spectrophotometric method. The LED and photodiode pairs are found to successfully reproduce the spectroscopic determination of red blood cell agglutination.

  2. Reminiscences of a mouse specific-locus test addict.

    PubMed

    Russell, W L

    1989-01-01

    This paper describes some of the historical events surrounding the development of and achievements with the mouse specific-locus test in radiation and chemical mutagenesis. Some ongoing and future contributions of the test to research in molecular genetics are also mentioned.

  3. Combined albumin and bicarbonate induces head-to-head sperm agglutination which physically prevents equine sperm-oviduct binding.

    PubMed

    Leemans, Bart; Gadella, Bart M; Stout, Tom A E; Sostaric, Edita; De Schauwer, Catharina; Nelis, Hilde; Hoogewijs, Maarten; Van Soom, Ann

    2016-04-01

    In many species, sperm binding to oviduct epithelium is believed to be an essential step in generating a highly fertile capacitated sperm population primed for fertilization. In several mammalian species, this interaction is based on carbohydrate-lectin recognition. D-galactose has previously been characterized as a key molecule that facilitates sperm-oviduct binding in the horse. We used oviduct explant and oviduct apical plasma membrane (APM) assays to investigate the effects of various carbohydrates; glycosaminoglycans; lectins; S-S reductants; and the capacitating factors albumin, Ca(2+) and HCO3(-) on sperm-oviduct binding in the horse. Carbohydrate-specific lectin staining indicated that N-acetylgalactosamine, N-acetylneuraminic acid (sialic acid) and D-mannose or D-glucose were the most abundant carbohydrates on equine oviduct epithelia, whereas D-galactose moieties were not detected. However, in a competitive binding assay, sperm-oviduct binding density was not influenced by any tested carbohydrates, glycosaminoglycans, lectins or D-penicillamine, nor did the glycosaminoglycans induce sperm tail-associated protein tyrosine phosphorylation. Furthermore, N-glycosidase F (PNGase) pretreatment of oviduct explants and APM did not alter sperm-oviduct binding density. By contrast, a combination of the sperm-capacitating factors albumin and HCO3(-) severely reduced (>10-fold) equine sperm-oviduct binding density by inducing rapid head-to-head agglutination, both of which events were independent of Ca(2+) and an elevated pH (7.9). Conversely, neither albumin and HCO3(-) nor any other capacitating factor could induce release of oviduct-bound sperm. In conclusion, a combination of albumin and HCO3(-) markedly induced sperm head-to-head agglutination which physically prevented stallion sperm to bind to oviduct epithelium.

  4. 9. "TEST STAND; STRUCTURAL; CABLE TUNNEL, PLAN, SECTIONS, DETAILS." Specifications ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. "TEST STAND; STRUCTURAL; CABLE TUNNEL, PLAN, SECTIONS, DETAILS." Specifications No. OC1-55-72-(Rev.); Drawing No. 60-09-12; sheet 43 of 148; file no. AF 1320/94, Rev. A. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  5. 8. "TEST STAND, ARCHITECTURAL, FLOOR PLANS AND SCHEDULES." Specifications No. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. "TEST STAND, ARCHITECTURAL, FLOOR PLANS AND SCHEDULES." Specifications No. ENG-04-353-55-72; Drawing No. 60-0912; sheet 22 of 148; file no. 1320/73. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  6. 5. "TEST STAND 13, CONCRETE STRUCTURAL SECTIONS AND DETAILS." Specifications ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. "TEST STAND 1-3, CONCRETE STRUCTURAL SECTIONS AND DETAILS." Specifications No. OC12-50-10; Drawing No. 60-09-06; no sheet number within title block. D.O. SERIES 1109/17, Rev. A. Stamped: AS BUILT; NO CHANGES. Date of Revision A: 11/1/50. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  7. Item Specifications, Science Grade 6. Blue Prints for Testing Minimum Performance Test.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    These item specifications were developed as a part of the Arkansas "Minimum Performance Testing Program" (MPT). There is one item specification for each instructional objective included in the MPT. The purpose of an item specification is to provide an overview of the general content and format of test items used to measure an…

  8. Item Specifications, Science Grade 8. Blue Prints for Testing Minimum Performance Test.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    These item specifications were developed as a part of the Arkansas "Minimum Performance Testing Program" (MPT). There is one item specification for each instructional objective included in the MPT. The purpose of an item specification is to provide an overview of the general content and format of test items used to measure an…

  9. Evolution of Shock Melt Compositions in Lunar Agglutinates

    NASA Technical Reports Server (NTRS)

    Vance, A. M.; Christoffersen, R.; Keller, L. P.

    2015-01-01

    Lunar agglutinates are aggregates of regolith grains fused together in a glassy matrix of shock melt produced during smaller-scale (mostly micrometeorite) impacts. Agglutinate formation is a key space weathering process under which the optically-active component of nanophase metallic Fe (npFe(sup 0)) is added to the lunar regolith. Here we have used energy-dispersive X-ray (EDX) compositional spectrum imaging in the SEM to quantify the chemical homogeneity of agglutinitic glass, correlate its homogeneity to its parent soil maturity, and identify the principle chemical components contributing to the shock melt compositional variations.

  10. Assessing a Critical Aspect of Construct Continuity when Test Specifications Change or Test Forms Deviate from Specifications

    ERIC Educational Resources Information Center

    Liu, Jinghua; Dorans, Neil J.

    2013-01-01

    We make a distinction between two types of test changes: inevitable deviations from specifications versus planned modifications of specifications. We describe how score equity assessment (SEA) can be used as a tool to assess a critical aspect of construct continuity, the equivalence of scores, whenever planned changes are introduced to testing…

  11. 3. "TEST STAND NO. 13, EXCAVATION PLAN & SECTIONS." Specifications ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. "TEST STAND NO. 1-3, EXCAVATION PLAN & SECTIONS." Specifications No. ENG 04-353-50-10; Drawing No. 60-0906; no sheet number within title block; D.O. SERIES 1109/10. Stamped: AS BUILT. No revisions or revision dates. Last work date on this drawing "Checked by EAG, 1/31/49." Though this drawing is specific to Test Stand 1-3, it also illustrates the general methods used for excavation design and retaining wall construction at Test Stand 1-5. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  12. A Test of Confusion Theory of Encoding Specificity

    ERIC Educational Resources Information Center

    Wiseman, Sandor; Tulving, Endel

    1975-01-01

    Subjects studied and were tested for recognition and recall of target words on lists of cue-target word pairs. List-cued recall was higher than non-cued recall, suggesting that recognition failure is independent of subjects' familiarity with task requirements. This contradicts attribution of encoding specificity phenomena to subjects' confusion.…

  13. Empirically Derived Test Specifications for the Certified Rehabilitation Counselor Examination

    ERIC Educational Resources Information Center

    Leahy, Michael J.; Chan, Fong; Sung, Connie; Kim, Muwoong

    2013-01-01

    This study examined the major job functions and knowledge domains required for effective rehabilitation counseling practice in today's rapidly changing practice environment to revise and update the test specifications for the Commission on Rehabilitation Counselor Certification examination. This report describes the methodology used in this…

  14. Agglutinates as recorders of regolith evolution - Application to the Apollo 17 drill core

    SciTech Connect

    Laul, J.C.; Smith, M.R.

    1984-11-15

    Chemical data are reported for agglutinates from 26 depth intervals of the Apollo 17 deep drill core, and the compositions of the agglutinates are compared with those of the soils in which they occur. The agglutinate sequence suggests a scenario in which several closely-spaced depositional events were involved in the formation of the drill core, rather than a continuous accumulation process.

  15. [Comparative measurement of antithrombin III by latex agglutination and radial immunodiffusion in patients with peritonitis].

    PubMed

    Miagkova, M A; Aleshkin, A V; Abramenko, T V; Savitskaia, Iu A; Aleshkin, V A

    1997-01-01

    A highly sensitive and rapid method, based on latex agglutination, has been developed for measuring antithrombin III (AT III) in the blood serum of patients and donors. The sensitivity of analysis is 0.6 microgram/ml, time 2 to 3 min. The method is simple, requires no sophisticated equipment, and may be used under field conditions. The results are assessed visually. Immunochemical reagents have been synthesized for the method: latex conjugates and specific antibodies to AT III. The method was tried in patients with peritonitis. An additional criterion for diagnosing the respiratory distress syndrome of adults in this patient population has been developed.

  16. Novel speed test for evaluation of badminton-specific movements.

    PubMed

    Madsen, Christian M; Karlsen, Anders; Nybo, Lars

    2015-05-01

    In this study, we developed a novel badminton-specific speed test (BST). The test was designed to mimic match play. The test starts in the center of the court and consists of 5 maximal actions to sensors located in each of the 4 corners of the court. The 20 actions are performed in randomized order as dictated by computer screen shots displayed 1 second after completion of the previous action. We assessed day-to-day variation in elite players, and specificity of the test was evaluated by comparing 30-m sprint performance and time to complete the BST in 20 elite players, 21 skilled players, and 20 age-matched physical active subjects (non-badminton players). Sprint performance was similar across groups, whereas the elite players were significantly (p ≤ 0.05) faster in the BST (total test time: 32.3 ± 1.1 seconds; average: 1.6 seconds per action) than the skilled (34.1 ± 2.0 seconds) and non-badminton players (35.7 ± 1.7 seconds). Day-to-day coefficient of variation (CV) of the BST was 0.7% for the elite players, whereas CV for repeated tests on the same day was 1.7% for elite, 2.6% for skilled, and 2.5% for non-badminton players. On this basis, we suggest that the BST may be valuable for evaluation of short-term maximal movement speed in badminton players. Thus, the BST seems to be sport specific, as it may discriminate between groups (elite, less trained players, and non-badminton players) with similar sprinting performance, and the low test-retest variation may allow for using the BST to evaluate longitudinal changes, for example, training effects or seasonal variations.

  17. Mononucleosis spot test

    MedlinePlus

    Monospot test; Heterophile antibody test; Heterophile agglutination test; Paul-Bunnell test; Forssman antibody test ... The mononucleosis spot test is done when symptoms of mononucleosis are ... Fatigue Fever Large spleen (possibly) Sore throat Tender ...

  18. Antibodies to spermatozoa. I. A new macroscopic agglutination technique for their detection, using immotile sperm

    PubMed Central

    Shulman, S.; Hekman, Annemarie

    1971-01-01

    An agglutination procedure, especially useful for guinea-pig sperm, has been developed. The preferred conditions are as follows: epididymal spermatozoa, in an immotile condition, unwashed or diluted and centrifuged once, at a concentration of 10×106 per ml diluted in phosphate-buffered saline, are incubated with antiserum samples in capillary tubes at 4°C for 1 or 2 hr of observation. This procedure has readily allowed us to detect the presence of antibodies against epididymal spermatozoa. The test has given results that are quite parallel to those obtained by the conventional Kibrick method. ImagesFig. 1Fig. 2 PMID:5570676

  19. Tests and specifications pertinent to coal ash utilization

    SciTech Connect

    Manz, O.

    1994-12-31

    Fortunately, in the United States, most of the test methods and specifications for the use of coal ash in cement, concrete, lime, or soil-related products are found in the American Society for Testing and Materials (ASTM) books of standards. Many of the same or slightly different specifications are also found in the American Association of State Highway and Transportation Officials (AASHTO) books of standards, as well as those of the various Departments of Transportation (DOTs). Other specifications for selected uses are found in publications of the American Petroleum Institute (API), the Sulfur Institute, the mineral wool industry, and West Virginia University. It is difficult to keep up with the most recent printed specifications, particularly in ASTM, since the committees meet twice yearly and have many time-consuming ballots. This paper summarizes the critical engineering properties required to assess the utilization applications of coal ash products. For most uses, both physical and chemical limits are specified. There are specifications for blended cement containing fly ash, for sulfate resistance, and for alkali aggregate reaction, also for fly ash for use in concrete, in oil well cement, and in grout. Coal ash is specified for use in ash-lime stabilization, as lightweight aggregate, and for mineral filler, as well as for structural fill and flowable fill. Other uses include sulfur concrete, high flexural strength ceramics, mineral wool, brick, cenospheres, and filler.

  20. Development of a Specific Anaerobic Field Test for Aerobic Gymnastics

    PubMed Central

    Paineli, Vitor de Salles; Azevedo, Rafael de Almeida; Borelli, Claudia Cristine Gomes; Lancha Junior, Antônio Herbert; Gualano, Bruno; Artioli, Guilherme Giannini

    2015-01-01

    The current investigation aimed to develop a valid specific field test to evaluate anaerobic physical performance in Aerobic Gymnastics athletes. We first designed the Specific Aerobic Gymnast Anaerobic Test (SAGAT), which included gymnastics-specific elements performed in maximal repeated sprint fashion, with a total duration of 80-90 s. In order to validate the SAGAT, three independent sub-studies were performed to evaluate the concurrent validity (Study I, n=8), the reliability (Study II, n=10) and the sensitivity (Study III, n=30) of the test in elite female athletes. In Study I, a positive correlation was shown between lower-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.69, CI: -0.94 to 0.03 and Peak power: p = 0.02, r = -0.72, CI: -0.95 to -0.04) and between upper-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.67, CI: -0.94 to 0.02 and Peak power: p = 0.03, r = -0.69, CI: -0.94 to 0.03). Additionally, plasma lactate was similarly increased in response to SAGAT (p = 0.002), lower-body Wingate Test (p = 0.021) and a simulated competition (p = 0.007). In Study II, no differences were found between the time to complete the SAGAT in repeated trials (p = 0.84; Cohen’s d effect size = 0.09; ICC = 0.97, CI: 0.89 to 0.99; MDC95 = 0.12 s). Finally, in Study III the time to complete the SAGAT was significantly lower during the competition cycle when compared to the period before the preparatory cycle (p < 0.001), showing an improvement in SAGAT performance after a specific Aerobic Gymnastics training period. Taken together, these data have demonstrated that SAGAT is a specific, reliable and sensitive measurement of specific anaerobic performance in elite female Aerobic Gymnastics, presenting great potential to be largely applied in training settings. PMID:25876039

  1. Development of a specific anaerobic field test for aerobic gymnastics.

    PubMed

    Alves, Christiano Robles Rodrigues; Borelli, Marcello Tadeu Caetano; Paineli, Vitor de Salles; Azevedo, Rafael de Almeida; Borelli, Claudia Cristine Gomes; Lancha Junior, Antônio Herbert; Gualano, Bruno; Artioli, Guilherme Giannini

    2015-01-01

    The current investigation aimed to develop a valid specific field test to evaluate anaerobic physical performance in Aerobic Gymnastics athletes. We first designed the Specific Aerobic Gymnast Anaerobic Test (SAGAT), which included gymnastics-specific elements performed in maximal repeated sprint fashion, with a total duration of 80-90 s. In order to validate the SAGAT, three independent sub-studies were performed to evaluate the concurrent validity (Study I, n=8), the reliability (Study II, n=10) and the sensitivity (Study III, n=30) of the test in elite female athletes. In Study I, a positive correlation was shown between lower-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.69, CI: -0.94 to 0.03 and Peak power: p = 0.02, r = -0.72, CI: -0.95 to -0.04) and between upper-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.67, CI: -0.94 to 0.02 and Peak power: p = 0.03, r = -0.69, CI: -0.94 to 0.03). Additionally, plasma lactate was similarly increased in response to SAGAT (p = 0.002), lower-body Wingate Test (p = 0.021) and a simulated competition (p = 0.007). In Study II, no differences were found between the time to complete the SAGAT in repeated trials (p = 0.84; Cohen's d effect size = 0.09; ICC = 0.97, CI: 0.89 to 0.99; MDC95 = 0.12 s). Finally, in Study III the time to complete the SAGAT was significantly lower during the competition cycle when compared to the period before the preparatory cycle (p < 0.001), showing an improvement in SAGAT performance after a specific Aerobic Gymnastics training period. Taken together, these data have demonstrated that SAGAT is a specific, reliable and sensitive measurement of specific anaerobic performance in elite female Aerobic Gymnastics, presenting great potential to be largely applied in training settings.

  2. Benchmark specifications for EBR-II shutdown heat removal tests

    SciTech Connect

    Sofu, T.; Briggs, L. L.

    2012-07-01

    Argonne National Laboratory (ANL) is hosting an IAEA-coordinated research project on benchmark analyses of sodium-cooled fast reactor passive safety tests performed at the Experimental Breeder Reactor-II (EBR-II). The benchmark project involves analysis of a protected and an unprotected loss of flow tests conducted during an extensive testing program within the framework of the U.S. Integral Fast Reactor program to demonstrate the inherently safety features of EBR-II as a pool-type, sodium-cooled fast reactor prototype. The project is intended to improve the participants' design and safety analysis capabilities for sodium-cooled fast reactors through validation and qualification of safety analysis codes and methods. This paper provides a description of the EBR-II tests included in the program, and outlines the benchmark specifications being prepared to support the IAEA-coordinated research project. (authors)

  3. Efficient Noninferiority Testing Procedures for Simultaneously Assessing Sensitivity and Specificity of Two Diagnostic Tests.

    PubMed

    Shan, Guogen; Amei, Amei; Young, Daniel

    2015-01-01

    Sensitivity and specificity are often used to assess the performance of a diagnostic test with binary outcomes. Wald-type test statistics have been proposed for testing sensitivity and specificity individually. In the presence of a gold standard, simultaneous comparison between two diagnostic tests for noninferiority of sensitivity and specificity based on an asymptotic approach has been studied by Chen et al. (2003). However, the asymptotic approach may suffer from unsatisfactory type I error control as observed from many studies, especially in small to medium sample settings. In this paper, we compare three unconditional approaches for simultaneously testing sensitivity and specificity. They are approaches based on estimation, maximization, and a combination of estimation and maximization. Although the estimation approach does not guarantee type I error, it has satisfactory performance with regard to type I error control. The other two unconditional approaches are exact. The approach based on estimation and maximization is generally more powerful than the approach based on maximization.

  4. Phased Startup Initiative Phases 3 and 4 Test Plan and Test Specification (OCRWM)

    SciTech Connect

    PITNER, A.L.

    2000-02-28

    Construction for the Spent Nuclear Fuel (SNF) Project facilities is continuing per the Level III Baseline Schedule, and installation of the Fuel Retrieval System (FRS) and Integrated Water Treatment System (IWTS) in K West Basin is now complete. In order to accelerate the project, a phased start up strategy to initiate testing of the FRS and IWTS early in the overall project schedule was proposed (Williams 1999). Wilkinson (1999) expands the definition of the original proposal into four functional testing phases of the Phased Startup Initiative (PSI). Phases 1 and 2 are based on performing functional tests using dummy fuel. These tests are described in separate planning documents. This test plan provides overall guidance for Phase 3 and 4 tests, which are performed using actual irradiated N fuel assemblies. The overall objective of the Phase 3 and 4 testing is to verify how the FRS and IWTS respond while processing actual fuel. Conducting these tests early in the project schedule will allow identification and resolution of equipment and process problems before they become activities on the start-up critical path. The specific objectives of this test plan are to: (1) Define the test scope for the FRS and IWTS; (2) Provide detailed test requirements that can be used to write the specific test procedures; (3) Define data required and measurements to be taken. Where existing methods to obtain these do not exist, enough detail will be provided to define required additional equipment; and (4) Define specific test objectives and acceptance criteria.

  5. 14. "SITE WORK, CIVIL, SITE PLAN." Test Area 1120. Specifications ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. "SITE WORK, CIVIL, SITE PLAN." Test Area 1-120. Specifications No. OC2-55-72; Drawing No. 60-09-12; sheet 7 of 148; file no. 1320/58, Rev. C. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338 Rev. C, Date: 16 April 1957. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA

  6. Force limit specifications vs. design limit loads in vibration testing

    NASA Technical Reports Server (NTRS)

    Chang, K. Y.

    2000-01-01

    The purpose of the work presented herein is to discuss the results of force limit notching during vibration testing with respect to the traditional limit load design criteria. By using a single-degree-of-freedom (SDOF) system approach, this work shows that with an appropriate force specification the notched response due to force limiting will result in loads comparable with the structural design limit criteria.

  7. Multiloop Integral System Test (MIST): MIST Facility Functional Specification

    SciTech Connect

    Habib, T F; Koksal, C G; Moskal, T E; Rush, G C; Gloudemans, J R

    1991-04-01

    The Multiloop Integral System Test (MIST) is part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock and Wilcox designed plants. MIST is sponsored by the US Nuclear Regulatory Commission, the Babcock Wilcox Owners Group, the Electric Power Research Institute, and Babcock and Wilcox. The unique features of the Babcock and Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral facilities to address the thermal-hydraulic SBLOCA questions. MIST was specifically designed and constructed for this program, and an existing facility -- the Once Through Integral System (OTIS) -- was also used. Data from MIST and OTIS are used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The MIST Functional Specification documents as-built design features, dimensions, instrumentation, and test approach. It also presents the scaling basis for the facility and serves to define the scope of work for the facility design and construction. 13 refs., 112 figs., 38 tabs.

  8. Phase Startup Initiative Phases 3 and 4 Test Plan and Test Specification ( OCRWM)

    SciTech Connect

    PAJUNEN, A.L.; LANGEVIN, M.J.

    2000-08-07

    Construction for the Spent Nuclear Fuel (SNF) Project facilities is continuing per the Level III Baseline Schedule, and installation of the Fuel Retrieval System (FRS) and Integrated Water Treatment System (IWTS) in K West Basin is now complete. In order to accelerate the project, a phased start up strategy to initiate testing of the FRS and IWTS early in the overall project schedule was proposed (Williams 1999). Wilkinson (1999) expands the definition of the original proposal into four functional testing phases of the Phased Startup Initiative (PSI). Phases 1 and 2 are based on performing functional tests using dummy fuel. This test plan provides overall guidance for Phase 3 and 4 tests, which are performed using actual irradiated N fuel assemblies. The overall objective of the Phase 3 and 4 testing is to verify how the FRS and IWTS respond while processing actual fuel. Conducting these tests early in the project schedule will allow identification and resolution of equipment and process problems before they become activities on the start-up critical path. The specific objectives of this test plan are to: Define the Phase 3 and 4 test scope for the FRS and IWTS; Provide detailed test requirements that can be used to write the specific test procedures; Define data required and measurements to be taken. Where existing methods to obtain these do not exist, enough detail will be provided to define required additional equipment; and Define specific test objectives and acceptance criteria.

  9. Performance of CHROMagar Staph aureus and CHROMagar MRSA for detection of Staphylococcus aureus in seawater and beach sand--comparison of culture, agglutination, and molecular analyses.

    PubMed

    Goodwin, K D; Pobuda, M

    2009-11-01

    Beach seawater and sand were analyzed for Staphylococcus aureus and methicillin resistant S. aureus (MRSA) for samples collected from Avalon, and Doheny Beach, CA. Membrane filtration followed by incubation on CHROMagar Staph aureus (SCA) and CHROMagar MRSA (C-MRSA) was used to enumerate S. aureus and MRSA, respectively. Media performance was evaluated by comparing identification via colony morphology and latex agglutination tests to PCR (clfA, 16S, and mecA genes). Due to background color and crowding, picking colonies from membrane filters and streaking for isolation were sometimes necessary. The specificity of SCA and C-MRSA was improved if colony isolates were identified by the presence of a matte halo in addition to mauve color; however routine agglutination testing of isolates did not appear warranted. Using the appearance of a colony on the membrane filter in conjunction with isolate appearance, the positive % agreement, the negative % agreement, and the % positive predictive accuracy for SCA was 84%, 95%, and 99% respectively, and for C-MRSA it was 85%, 98%, and 92%, respectively. Sensitivity and specificity of SCA and C-MRSA with membrane-filtered beach samples were optimized through identification experience, control of filter volume and incubation time, and isolation of colonies needing further identification. With optimization, SCA and C-MRSA could be used for enumeration of S. aureus and MRSA from samples of beach water and sand. For the sites studied here, the frequency of detection of S. aureus ranged from 60 to 76% and 53 to 79% for samples of beach seawater and sand, respectively. The frequency of detection of MRSA ranged from 2 to 9% and 0 to 12% for samples of seawater and sand, respectively.

  10. A test of the domain-specific acculturation strategy hypothesis.

    PubMed

    Miller, Matthew J; Yang, Minji; Lim, Robert H; Hui, Kayi; Choi, Na-Yeun; Fan, Xiaoyan; Lin, Li-Ling; Grome, Rebekah E; Farrell, Jerome A; Blackmon, Sha'kema

    2013-01-01

    Acculturation literature has evolved over the past several decades and has highlighted the dynamic ways in which individuals negotiate experiences in multiple cultural contexts. The present study extends this literature by testing M. J. Miller and R. H. Lim's (2010) domain-specific acculturation strategy hypothesis-that individuals might use different acculturation strategies (i.e., assimilated, bicultural, separated, and marginalized strategies; J. W. Berry, 2003) across behavioral and values domains-in 3 independent cluster analyses with Asian American participants. Present findings supported the domain-specific acculturation strategy hypothesis as 67% to 72% of participants from 3 independent samples using different strategies across behavioral and values domains. Consistent with theory, a number of acculturation strategy cluster group differences emerged across generational status, acculturative stress, mental health symptoms, and attitudes toward seeking professional psychological help. Study limitations and future directions for research are discussed.

  11. 29. "TEST TRACK, STATION '0' THROUGH '200' AREA." Specifications No. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. "TEST TRACK, STATION '0' THROUGH '200' AREA." Specifications No. ENG-OC-1-57-75, Drawing No. AF-6009-15, sheet 53 of 96, D.O. Series No. AF 1394/73, Rev. C. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 5296 Rev. C, Date: 19 NOV 59. Drawing includes plan, section, and details of track. - Edwards Air Force Base, South Base Sled Track, Edwards Air Force Base, North of Avenue B, between 100th & 140th Streets East, Lancaster, Los Angeles County, CA

  12. Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design

    NASA Astrophysics Data System (ADS)

    Potthoff, Annegret; Weil, Mirco; Meißner, Tobias; Kühnel, Dana

    2015-12-01

    During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure—physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing.

  13. Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design

    PubMed Central

    Potthoff, Annegret; Weil, Mirco; Meißner, Tobias; Kühnel, Dana

    2015-01-01

    During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure—physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing. PMID:27877848

  14. Measurement of RBC agglutination with microscopic cell image analysis in a microchannel chip.

    PubMed

    Cho, Chi Hyun; Kim, Ju Yeon; Nyeck, Agnes E; Lim, Chae Seung; Hur, Dae Sung; Chung, Chanil; Chang, Jun Keun; An, Seong Soo A; Shin, Sehyun

    2014-01-01

    Since Landsteiner's discovery of ABO blood groups, RBC agglutination has been one of the most important immunohematologic techniques for ABO and RhD blood groupings. The conventional RBC agglutination grading system for RhD blood typings relies on macroscopic reading, followed by the assignment of a grade ranging from (-) to (4+) to the degree of red blood cells clumping. However, with the new scoring method introduced in this report, microscopically captured cell images of agglutinated RBCs, placed in a microchannel chip, are used for analysis. Indeed, the cell images' pixel number first allows the differentiation of agglutinated and non-agglutinated red blood cells. Finally, the ratio of agglutinated RBCs per total RBC counts (CRAT) from 90 captured images is then calculated. During the trial, it was observed that the agglutinated group's CRAT was significantly higher (3.77-0.003) than that of the normal control (0). Based on these facts, it was established that the microchannel method was more suitable for the discrimination between agglutinated RBCs and non-agglutinated RhD negative, and thus more reliable for the grading of RBCs agglutination than the conventional method.

  15. Does McNemar's test compare the sensitivities and specificities of two diagnostic tests?

    PubMed

    Kim, Soeun; Lee, Woojoo

    2017-02-01

    McNemar's test is often used in practice to compare the sensitivities and specificities for the evaluation of two diagnostic tests. For correct evaluation of accuracy, an intuitive recommendation is to test the diseased and the non-diseased groups separately so that the sensitivities can be compared among the diseased, and specificities can be compared among the healthy group of people. This paper provides a rigorous theoretical framework for this argument and study the validity of McNemar's test regardless of the conditional independence assumption. We derive McNemar's test statistic under the null hypothesis considering both assumptions of conditional independence and conditional dependence. We then perform power analyses to show how the result is affected by the amount of the conditional dependence under alternative hypothesis.

  16. Domain-specific functional software testing: A progress report

    NASA Technical Reports Server (NTRS)

    Nonnenmann, Uwe

    1992-01-01

    Software Engineering is a knowledge intensive activity that involves defining, designing, developing, and maintaining software systems. In order to build effective systems to support Software Engineering activities, Artificial Intelligence techniques are needed. The application of Artificial Intelligence technology to Software Engineering is called Knowledge-based Software Engineering (KBSE). The goal of KBSE is to change the software life cycle such that software maintenance and evolution occur by modifying the specifications and then rederiving the implementation rather than by directly modifying the implementation. The use of domain knowledge in developing KBSE systems is crucial. Our work is mainly related to one area of KBSE that is called automatic specification acquisition. One example is the WATSON prototype on which our current work is based. WATSON is an automatic programming system for formalizing specifications for telephone switching software mainly restricted to POTS, i.e., plain old telephone service. Our current approach differentiates itself from other approaches in two antagonistic ways. On the one hand, we address a large and complex real-world problem instead of a 'toy domain' as in many research prototypes. On the other hand, to allow such scaling, we had to relax the ambitious goal of complete automatic programming, to the easier task of automatic testing.

  17. Criterion Related Validity of Karate Specific Aerobic Test (KSAT)

    PubMed Central

    Chaabene, Helmi; Hachana, Younes; Franchini, Emerson; Tabben, Montassar; Mkaouer, Bessem; Negra, Yassine; Hammami, Mehrez; Chamari, Karim

    2015-01-01

    Background: Karate is one the most popular combat sports in the world. Physical fitness assessment on a regular manner is important for monitoring the effectiveness of the training program and the readiness of karatekas to compete. Objectives: The aim of this research was to examine the criterion related to validity of the karate specific aerobic test (KSAT) as an indicator of aerobic level of karate practitioners. Patients and Methods: Cardiorespiratory responses, aerobic performance level through both treadmill laboratory test and YoYo intermittent recovery test level 1 (YoYoIRTL1) as well as time to exhaustion in the KSAT test (TE’KSAT) were determined in a total of fifteen healthy international karatekas (i.e. karate practitioners) (means ± SD: age: 22.2 ± 4.3 years; height: 176.4 ± 7.5 cm; body mass: 70.3 ± 9.7 kg and body fat: 13.2 ± 6%). Results: Peak heart rate obtained from KSAT represented ~99% of maximal heart rate registered during the treadmill test showing that KSAT imposes high physiological demands. There was no significant correlation between KSAT’s TE and relative (mL/min kg) treadmill maximal oxygen uptake (r = 0.14; P = 0.69; [small]). On the other hand, there was a significant relationship between KSAT’s TE and the velocity associated with VO2max (vVO2max) (r = 0.67; P = 0.03; [large]) as well as the velocity at VO2 corresponding to the second ventilatory threshold (vVO2 VAT) (r = 0.64; P = 0.04; [large]). Moreover, significant relationship was found between TE’s KSAT and both the total distance covered and parameters of intermittent endurance measured through YoYoIRTL1. Conclusions: The KSAT has not proved to have indirect criterion related validity as no significant correlations have been found between TE’s KSAT and treadmill VO2max. Nevertheless, as correlated to other aerobic fitness variables, KSAT can be considered as an indicator of karate specific endurance. The establishment of the criterion related validity of the KSAT

  18. Amyloidogenic amyloid-β-peptide variants induce microbial agglutination and exert antimicrobial activity

    PubMed Central

    Spitzer, Philipp; Condic, Mateja; Herrmann, Martin; Oberstein, Timo Jan; Scharin-Mehlmann, Marina; Gilbert, Daniel F.; Friedrich, Oliver; Grömer, Teja; Kornhuber, Johannes; Lang, Roland; Maler, Juan Manuel

    2016-01-01

    Amyloid-β (Aβ) peptides are the main components of the plaques found in the brains of patients with Alzheimer’s disease. However, Aβ peptides are also detectable in secretory compartments and peripheral blood contains a complex mixture of more than 40 different modified and/or N- and C-terminally truncated Aβ peptides. Recently, anti-infective properties of Aβ peptides have been reported. Here, we investigated the interaction of Aβ peptides of different lengths with various bacterial strains and the yeast Candida albicans. The amyloidogenic peptides Aβ1-42, Aβ2-42, and Aβ3p-42 but not the non-amyloidogenic peptides Aβ1-40 and Aβ2-40 bound to microbial surfaces. As observed by immunocytochemistry, scanning electron microscopy and Gram staining, treatment of several bacterial strains and Candida albicans with Aβ peptide variants ending at position 42 (Aβx-42) caused the formation of large agglutinates. These aggregates were not detected after incubation with Aβx-40. Furthermore, Aβx-42 exerted an antimicrobial activity on all tested pathogens, killing up to 80% of microorganisms within 6 h. Aβ1-40 only had a moderate antimicrobial activity against C. albicans. Agglutination of Aβ1-42 was accelerated in the presence of microorganisms. These data demonstrate that the amyloidogenic Aβx-42 variants have antimicrobial activity and may therefore act as antimicrobial peptides in the immune system. PMID:27624303

  19. Prevalence of agglutinating antibodies to Toxoplasma gondii and Sarcocystis neurona in beavers (Castor canadensis) from Massachusetts.

    PubMed

    Jordan, Carly N; Kaur, Taranjit; Koenen, Kiana; DeStefano, Stephen; Zajac, Anne M; Lindsay, David S

    2005-10-01

    The present study examined the seroprevalence of Toxoplasma gondii and Sarcocystis neurona in a population of beavers (Castor canadensis) from Massachusetts. Sixty-two blood samples were collected during the field seasons over 3 consecutive years from different animals. Blood was collected onto filter paper and shipped to the Department of Biomedical Sciences, Virginia Tech, Blacksburg, Virginia, for parasite testing. The samples were tested at dilutions of 1:25, 1:50, and 1:100 against each parasite antigen by modified agglutination tests to determine whether antibodies to either parasite were present in the blood. Six of 62 samples (10%) were positive for T. gondii, with 2 samples having titers of 1:25 and 4 having titers of 1:50. Four of 62 samples (6%) were positive for S. neurona, with 2 samples having titers of 1:25 and 2 having titers of 1:50.

  20. Prevalence of agglutinating antibodies to Toxoplasma gondii and Sarcocystis neurona in beavers (Castor canadensis) from Massachusetts

    USGS Publications Warehouse

    Jordan, C.N.; Kaur, T.; Koenen, K.; DeStefano, S.; Zajac, A.M.; Lindsay, D.S.

    2005-01-01

    The present study examined the seroprevalence of Toxoplasma gondii and Sarcocystls neurona in a population of beavers (Castor canadensis) from Massachusetts. Sixty-two blood samples were collected during the field seasons over 3 consecutive years from different animals. Blood was collected onto filter paper and shipped to the Department of Biomedical Sciences, Virginia Tech, Blacksburg, Virginia, for parasite testing. The samples were tested at dilutions of 1:25, 1:50, and 1:100 against each parasite antigen by modified agglutination tests to determine whether antibodies to either parasite were present in the blood. Six of 62 samples (10%) were positive for T. gondii, with 2 samples having titers of 1:25 and 4 having titers of 1:50. Four of 62 samples (6%) were positive for S. neurona, with 2 samples having titers of 1:25 and 2 having titers of 1:50. ?? American Society of Pathologists 2005.

  1. Agglutination of human O erythrocytes by influenza A(H1N1) viruses freshly isolated from patients.

    PubMed

    Murakami, T; Haruki, K; Seto, Y; Kimura, T; Minoshiro, S; Shibe, K

    1991-04-01

    The hemagglutinin titers of 10 influenza A (H1N1) viruses were examined using the erythrocytes of several species. Human O erythrocytes showed the highest agglutination titer to the viruses, whereas chicken erythrocytes showed a low titer. These findings were noted for at least 10 passages by serial dilutions of the viruses in Madin-Darby canine kidney (MDCK) cells. All influenza A(H1N1) viruses, plaque-cloned directly from throat-washing specimens of patients, also agglutinated human O but not chicken erythrocytes. The results of a hemadsorption test indicated that chicken erythrocytes possess less affinity to MDCK cells infected with the A/Osaka City/2/88(H1N1) stain than to those infected with the A/Yamagata/120/86(H1N1) strain which is used as an inactivated influenza vaccine in Japan. However, there were no significant differences between the A/Osaka City/2/88 and the A/Yamagata/120/86 strains in the hemagglutination inhibition test. Since human O erythrocytes have high agglutination activity to influenza A(H1N1) and also to A(H3N2) and B viruses in MDCK cells, these erythrocytes may be useful for the serological diagnosis of influenza.

  2. Test-specific control conditions for functional analyses.

    PubMed

    Fahmie, Tara A; Iwata, Brian A; Querim, Angie C; Harper, Jill M

    2013-01-01

    Most functional analyses of problem behavior include a common condition (play or noncontingent reinforcement) as a control for both positive and negative reinforcement. However, test-specific conditions that control for each potential source of reinforcement may be beneficial occasionally. We compared responding during alone, ignore, play, and differential reinforcement of other behavior (DRO) control conditions for individuals whose problem behavior was maintained by positive or negative reinforcement. Results showed that all of the conditions were effective controls for problem behavior maintained by positive reinforcement; however, the DRO condition was consistently ineffective as a control for problem behavior maintained by negative reinforcement. Implications for the design of functional analyses and future research are discussed.

  3. Testing the specificity between social anxiety disorder and drinking motives.

    PubMed

    Windle, Michael; Windle, Rebecca C

    2012-09-01

    This study tested the specificity of the relationship between social anxiety disorder (SAD) and coping drinking motives (versus enhancement drinking motives and social drinking motives) within the context of a range of potentially confounding variables measured during adolescence (e.g., quantity and frequency of alcohol use, coping drinking motives) and substantively important variables assessed during young adulthood (e.g., other anxiety disorders and major depressive disorder). A sample of high school sophomores and juniors (n=717) completed measures of substance use and risk factors during adolescence and were then prospectively followed-up in early- and middle-young adulthood, and psychiatric diagnoses and drinking motives (i.e., coping, enhancement, and social) were assessed each time. Findings indicated that SAD was specifically related to coping motives (measured during early-to-middle young adulthood) after controlling for the effects of a range of alcohol and mental health variables. In addition, adolescent variables predicted young adult drinking motives as did major depressive disorder and other anxiety disorders. These findings are discussed within a conceptual framework of the functional role (e.g., self-medication) that drinking motives, and especially coping drinking motives, may play in the etiology of alcohol problems and disorders. Implications for prevention and treatment interventions are discussed.

  4. Repeat Prostate-Specific Antigen Tests Before Prostate Biopsy Decisions.

    PubMed

    Nordström, Tobias; Adolfsson, Jan; Grönberg, Henrik; Eklund, Martin

    2016-12-01

    Despite limited scientific support, a repeat prostate-specific antigen (PSA) test before prostate biopsy decisions is common. We analyzed biopsy outcomes in 1686 men from the STHLM3 study with PSA 3-10 ng/mL and two PSA tests taken within eight weeks and before prostate biopsy using percentages and multinomial logistic regression. We found that omitting prostate biopsy for men with PSA values decreasing to PSAs of 3 ng/mL or less would save 16.8% of biopsy procedures, while missing 5.4% of the cancers with Gleason scores (GSs) of 7 or higher. The proportion of cancers with GSs of 6 or lower was independent of the first PSA value, as well as of PSA change. Also, the risk of tumors with GSs of 7 or higher decreased with both decreasing and increasing PSA levels: It was 18.6% (95% confidence interval [CI] = 16.3% to 20.9%) for men with PSA changes of less than 20%, 12.1% (95% CI = 8.0% to 16.2%) for men with PSA levels increasing at least 20%, and 6.6% (95% CI = 3.8% to 9.3%) for men with PSA levels decreasing at least 20%.

  5. A comparison of tests for thyroglobulin antibody

    PubMed Central

    Rawstron, J. R.; Farthing, C. P.

    1962-01-01

    A comparison is made of tests for thyroglobulin antibody, using gel diffusion, electroprecipitin, bentonite flocculation, tanned red cell agglutination, and latex slide agglutination techniques on sera from cases of Hashimoto's disease and other thyroid disorders. Any increase in γ globulin was also noted from the serum electrophoretic pattern. The gel diffusion and electroprecipitin tests are shown to be comparable in their sensitivity, as are the bentonite flocculation and tanned red cell agglutination tests. The flocculation and agglutination tests were oversensitive. The latex slide test in conjunction with the electro-precipitin test is recommended for routine use in the detection of Hashimoto's disease. Images PMID:14490690

  6. Quantitative determination of fibrinogen of patients with coronary heart diseases through piezoelectric agglutination sensor.

    PubMed

    Chen, Qinghai; Hua, Xing; Fu, Weiling; Liu, Dongbo; Chen, Ming; Cai, Guoru

    2010-01-01

    Fibrinogen can transform fibrin through an agglutination reaction, finally forming fibrin polymer with grid structure. The density and viscosity of the reaction system changes drastically during the course of agglutination. In this research, we apply an independently-developed piezoelectric agglutination sensor to detect the fibrinogen agglutination reaction in patients with coronary heart diseases. The terminal judgment method of determining plasma agglutination reaction through piezoelectric agglutination sensor was established. In addition, the standard curve between plasma agglutination time and fibrinogen concentration was established to determinate fibrinogen content quantitatively. The results indicate the close correlation between the STAGO paramagnetic particle method and the method of piezoelectric agglutination sensor for the detection of Fibrinogen. The correlation coefficient was 0.91 (γ = 0.91). The determination can be completed within 10 minutes. The fibrinogen concentration in the coronary heart disease group was significantly higher than that of the healthy control group (P < 0.05). The results reveal that high fibrinogen concentration is closely correlated to the incurrence, development and prognosis of coronary heart diseases. Compared with other traditional methods, the method of piezoelectric agglutination sensor has some merits such as operation convenience, small size, low cost, quick detecting, good precision and the common reacting agents with paramagnetic particle method.

  7. Agglutinating Activity and Structural Characterization of Scalarin, the Major Egg Protein of the Snail Pomacea scalaris (d’Orbigny, 1832)

    PubMed Central

    Ituarte, Santiago; Dreon, Marcos Sebastián; Ceolin, Marcelo; Heras, Horacio

    2012-01-01

    Apple snail perivitellins are emerging as ecologically important reproductive proteins. To elucidate if the protective functions of the egg proteins of Pomacea canaliculata (Caenogastropoda, Ampullariidae), involved in embryo defenses, are present in other Pomacea species we studied scalarin (PsSC), the major perivitellin of Pomacea scalaris. Using small angle X-ray scattering, fluorescence and absorption spectroscopy and biochemical methods, we analyzed PsSC structural stability, agglutinating activity, sugar specificity and protease resistance. PsSC aggluttinated rabbit, and, to a lesser extent, human B and A erythrocytes independently of divalent metals Ca2+ and Mg2+ were strongly inhibited by galactosamine and glucosamine. The protein was structurally stable between pH 2.0 to 10.0, though agglutination occurred only between pH 4.0 to 8.0 (maximum activity at pH 7.0). The agglutinating activity was conserved up to 60°C and completely lost above 80°C, in agreement with the structural thermal stability of the protein (up to 60°C). PsSC was able to withstand in vitro gastrointestinal digestion, and showed no trypsin inhibition activity. The presence of lectin activity has been reported in eggs of other Pomacea snails, but here we link for the first time, this activity to an apple snail multifunctional perivitellin. This novel role for a snail egg storage protein is different from closely related P.canaliculata defensive proteins. PMID:23185551

  8. Pilot test specific test plan for the removal of arsenic Socorro, New Mexico.

    SciTech Connect

    Collins, Sue S.; Aragon, Malynda Jo; Everett, Randy L.; Siegel, Malcolm Dean; Aragon, Alicia R.; Dwyer, Brian P.; Marbury, Justin Luke

    2006-03-01

    Sandia National Laboratories (SNL) is conducting pilot scale evaluations of the performance and cost of innovative drinking water treatment technologies designed to meet the new arsenic maximum contaminant level (MCL) of 10 {micro}g/L (effective January 2006). As currently envisioned, pilots tests may include multiple phases. Phase I tests will involve side-by-side comparisons of several commercial technologies primarily using design parameters suggested by the Vendors. Subsequent tests (Phase II) may involve repeating some of the original tests, testing the same commercial technologies under different conditions and testing experimental technologies or additional commercial technologies. This Pilot Test Specific Test Plan (PTSTP) was written for Phase I of the Socorro Springs Pilot. The objectives of Phase I include evaluation of the treatment performance of five adsorptive media under ambient pH conditions (approximately 8.0) and assessment of the effect of contact time on the performance of one of the media. Addenda to the PTSTP may be written to cover Phase II studies and supporting laboratory studies. The Phase I demonstration began in the winter of 2004 and will last approximately 9 months. The information from the test will help the City of Socorro choose the best arsenic treatment technology for the Socorro Springs well. The pilot demonstration is a project of the Arsenic Water Technology Partnership program, a partnership between the American Water Works Association (AWWA) Research Foundation, SNL, and WERC (A Consortium for Environmental Education and Technology Development).

  9. Restriction-Site-Specific PCR as a Rapid Test To Detect Enterohemorrhagic Escherichia coli O157:H7 Strains in Environmental Samples

    PubMed Central

    Kimura, Richard; Mandrell, Robert E.; Galland, John C.; Hyatt, Doreene; Riley, Lee W.

    2000-01-01

    Enterohemorrhagic Escherichia coli (EHEC) O157:H7 is an important food-borne pathogen in industrialized countries. We developed a rapid and simple test for detecting E. coli O157:H7 using a method based on restriction site polymorphisms. Restriction-site-specific PCR (RSS-PCR) involves the amplification of DNA fragments using primers based on specific restriction enzyme recognition sequences, without the use of endonucleases, to generate a set of amplicons that yield “fingerprint” patterns when resolved electrophoretically on an agarose gel. The method was evaluated in a blinded study of E. coli isolates obtained from environmental samples collected at beef cattle feedyards. The 54 isolates were all initially identified by a commonly used polyclonal antibody test as belonging to O157:H7 serotype. They were retested by anti-O157 and anti-H7 monoclonal antibody enzyme-linked immunosorbent assay (ELISA). The RSS-PCR method identified all 28 isolates that were shown to be E. coli O157:H7 by the monoclonal antibody ELISA as belonging to the O157:H7 serotype. Of the remaining 26 ELISA-confirmed non-O157:H7 strains, the method classified 25 strains as non-O157:H7. The specificity of the RSS-PCR results correlated better with the monoclonal antibody ELISA than with the polyclonal antibody latex agglutination tests. The RSS-PCR method may be a useful test to distinguish E. coli O157:H7 from a large number of E. coli isolates from environmental samples. PMID:10831431

  10. Studying red blood cell agglutination by measuring electrical and mechanical properties with a double optical tweezers

    NASA Astrophysics Data System (ADS)

    Fontes, Adriana; Fernandes, Heloise P.; de Thomaz, André A.; Barbosa, Luiz C.; Barjas-Castro, Maria L.; Cesar, Carlos L.

    2007-07-01

    The red blood cell (RBC) viscoelastic membrane contains proteins and glycolproteins embedded in, or attached, to a fluid lipid bilayer and are negatively charged, which creates a repulsive electric (zeta) potential between the cells and prevents their aggregation in the blood stream. The basis of the immunohematologic tests is the interaction between antigens and antibodies that causes hemagglutination. The identification of antibodies and antigens is of fundamental importance for the transfusional routine. This agglutination is induced by decreasing the zeta-potential through the introduction of artificial potential substances. This report proposes the use of the optical tweezers to measure the membrane viscosity, the cell adhesion, the zeta-potential and the size of the double layer of charges (CLC) formed around the cell in an electrolytic solution. The adhesion was quantified by slowly displacing two RBCs apart until the disagglutination. The CLC was measured using the force on the bead attached to a single RBC in response to an applied voltage. The zeta-potential was obtained by measuring the terminal velocity after releasing the RBC from the optical trap at the last applied voltage. For the membrane viscosity experiment, we trapped a bead attached to RBCs and measured the force to slide one RBC over the other as a function of the relative velocity. After we tested the methodology, we performed measurements using antibody and potential substances. We observed that this experiment can provide information about cell agglutination that helps to improve the tests usually performed in blood banks. We also believe that this methodology can be applied for measurements of zeta-potentials in other kind of samples.

  11. Comparison of two anaerobic water polo-specific tests with the Wingate test.

    PubMed

    Bampouras, Theodoros M; Marrin, Kelly

    2009-01-01

    The purpose of the current study was to compare 2 water polo-specific tests-the 14 x 25-m swims (SWIM) and the 30-second crossbar jumps (30CJ)-with a laboratory-based test of anaerobic power, the Wingate Anaerobic Test (WAnT). Thirteen elite women's water polo players (mean +/- SD: age 22.0 +/- 4.4 years, height 168.7 +/- 7.9 cm, body mass 65.9 +/- 6.1 kg, body fat 23.6 +/- 3.5 %, maximum oxygen uptake 51.4 +/- 4.5 mlxkgxmin) participated in the study. The SWIM involved 14 repeated "all-out" sprints every 30 seconds. Swimming time was recorded, and sprint velocity, mean velocity (Vmean), and the gradient of the linear regression equation (GRADIENT) were calculated. The 30CJ involved repeated in-water water polo jumps and touching the goal crossbar with both hands. The number of touches in 30 seconds was recorded. Additionally, the subjects completed a 30-second WAnT, and mean power (Mp) and fatigue index (FI) were calculated. Kendall tau (tau) rank correlation was used to examine for correlation between ranks. Significance level was set at p specific tests. It was suggested that the WAnT may not be an appropriate evaluation tool for anaerobic power assessment of water polo players, stressing the importance of sport-specific tests.

  12. An experimental investigation of agglutinate melting mechanisms - Shocked mixtures of sodium and potassium feldspars

    NASA Technical Reports Server (NTRS)

    Simon, S. B.; Papike, J. J.; Horz, F.; See, T. H.

    1985-01-01

    The results of an experiment designed to test the validity of the model for agglutinate formation involving fusion of the finest fraction or F3 are reported. Impact glasses were formed from various mixes of orthoclase and albite powders, which were used as analogs for soils with chemically constrasting coarse and fine fractions. The results showed that the single most important factor displacing the composition of a small-scale impact melt from the bulk composition of the source regolith is the fractionated composition of the finest soil fraction. Volatile loss and the amount of melting, which in turn are determined by the degree of shock, are also important. As predicted by the model, the lower pressure melts are the most fractionated, and higher pressure is accompanied by increased melting causing glass compositions to approach the bulk. In general, the systematics predicted by the model are observed; the model appears to be valid.

  13. A novel flow cytometry-based assay for the quantification of antibody-dependent pneumococcal agglutination

    PubMed Central

    van der Gaast—de Jongh, Christa E.; Diavatopoulos, Dimitri A.; de Jonge, Marien I.

    2017-01-01

    The respiratory pathogen Streptococcus pneumoniae is a major cause of diseases such as otitis media, pneumonia, sepsis and meningitis. The first step towards infection is colonization of the nasopharynx. Recently, it was shown that agglutinating antibodies play an important role in the prevention of mucosal colonization with S. pneumoniae. Here, we present a novel method to quantify antibody-dependent pneumococcal agglutination in a high-throughput manner using flow cytometry. We found that the concentration of agglutinating antibodies against pneumococcal capsule are directly correlated with changes in the size and complexity of bacterial aggregates, as measured by flow cytometry and confirmed by light microscopy. Using the increase in size, we determined the agglutination index. The cutoff value was set by measuring a series of non-agglutinating antibodies. With this method, we show that not only anti-polysaccharide capsule antibodies are able to induce agglutination but that also anti-PspA protein antibodies have agglutinating capabilities. In conclusion, we have described and validated a novel method to quantify pneumococcal agglutination, which can be used to screen sera from murine or human vaccination studies, in a high-throughput manner. PMID:28288168

  14. Sensitivity and specificity of typhoid fever rapid antibody tests for laboratory diagnosis at two sub-Saharan African sites

    PubMed Central

    Keddy, Karen H; Sooka, Arvinda; Letsoalo, Maupi E; Hoyland, Greta; Chaignat, Claire Lise; Morrissey, Anne B; Crump, John A

    2011-01-01

    Abstract Objective To evaluate three commercial typhoid rapid antibody tests for Salmonella Typhi antibodies in patients suspected of having typhoid fever in Mpumalanga, South Africa, and Moshi, United Republic of Tanzania. Methods The diagnostic accuracy of Cromotest® (semiquantitative slide agglutination and single tube Widal test), TUBEX® and Typhidot® was assessed against that of blood culture. Performance was modelled for scenarios with pretest probabilities of 5% and 50%. Findings In total 92 patients enrolled: 53 (57.6%) from South Africa and 39 (42.4%) from the United Republic of Tanzania. Salmonella Typhi was isolated from the blood of 28 (30.4%) patients. The semiquantitative slide agglutination and single-tube Widal tests had positive predictive values (PPVs) of 25.0% (95% confidence interval, CI: 0.6–80.6) and 20.0% (95% CI: 2.5–55.6), respectively. The newer typhoid rapid antibody tests had comparable PPVs: TUBEX®, 54.1% (95% CI: 36.9–70.5); Typhidot® IgM, 56.7% (95% CI: 37.4–74.5); and Typhidot® IgG, 54.3% (95% CI: 36.6–71.2). For a pretest probability of 5%, PPVs were: TUBEX®, 11.0% (95% CI: 6.6–17.9); Typhidot® IgM, 9.1% (95% CI: 5.8–14.0); and Typhidot® IgG, 11.0% (6.3–18.4). For a pretest probability of 50%, PPVs were: TUBEX®, 70.2% (95% CI: 57.3–80.5); Typhidot® IgM, 65.6% (95% CI: 54.0–75.6); and Typhidot® IgG, 70.0% (95% CI: 56.0–81.1). Conclusion Semiquantitative slide agglutination and single-tube Widal tests performed poorly. TUBEX® and Typhidot® may be suitable when pretest probability is high and blood cultures are unavailable, but their performance does not justify deployment in routine care settings in sub-Saharan Africa. PMID:21897484

  15. The Rapid Diagnosis of Leptospirosis: A Prospective Comparison of the Dot Enzyme-Linked Immunosorbent Assay and the Genus-Specific Microscopic Agglutination Test at Different Stages of Illness

    DTIC Science & Technology

    1988-04-01

    reference laboratories. Sim- ting" I liL of leptospiral antigen (770 ng of protein, Lowry pler techniques have been described, but information is...detect recent albumin for 1 min with shaking on a plane rotator. After exposure to leptospires ; it is also rapid and simpler to use aspiration of...by the isola, battery of 24 pathogenic serovars. Tenl, to 14.d-old cul- tion of leptospires fromt bloodi or urine. Only serologicil ture% wete

  16. An early Cambrian agglutinated tubular lophophorate with brachiopod characters

    PubMed Central

    Zhang, Z.-F.; Li, G.-X.; Holmer, L. E.; Brock, G. A.; Balthasar, U.; Skovsted, C. B.; Fu, D.-J.; Zhang, X.-L.; Wang, H.-Z.; Butler, A.; Zhang, Z.-L.; Cao, C.-Q.; Han, J.; Liu, J.-N.; Shu, D.-G.

    2014-01-01

    The morphological disparity of lophotrochozoan phyla makes it difficult to predict the morphology of the last common ancestor. Only fossils of stem groups can help discover the morphological transitions that occurred along the roots of these phyla. Here, we describe a tubular fossil Yuganotheca elegans gen. et sp. nov. from the Cambrian (Stage 3) Chengjiang Lagerstätte (Yunnan, China) that exhibits an unusual combination of phoronid, brachiopod and tommotiid (Cambrian problematica) characters, notably a pair of agglutinated valves, enclosing a horseshoe-shaped lophophore, supported by a lower bipartite tubular attachment structure with a long pedicle with coelomic space. The terminal bulb of the pedicle provided anchorage in soft sediment. The discovery has important implications for the early evolution of lophotrochozoans, suggesting rooting of brachiopods into the sessile lophotrochozoans and the origination of their bivalved bauplan preceding the biomineralization of shell valves in crown brachiopods. PMID:24828016

  17. Reliability and Factorial Validity of Non-Specific and Tennis-Specific Pre-Planned Agility Tests; Preliminary Analysis

    PubMed Central

    Sekulic, Damir; Uljevic, Ognjen; Peric, Mia; Spasic, Miodrag; Kondric, Miran

    2017-01-01

    Abstract Agility is an important quality in tennis, yet there is an evident lack of studies focussing on the applicability of tennis-specific agility performances and comparing them to equivalent non-specific agility performances. The aim of this study was to evaluate the reliability and factorial validity of three tests of pre-planned agility, performed in specific (with a tennis racquet) and non-specific (without a tennis racquet) conditions. The sample consisted of 33 tennis players (13 males and 20 females; age: 18.3 ± 1.1 years and 18.6 ± 1.3 years; body height: 185.4 ± 51 cm and 169.3 ± 4.2 cm, 74.0 ± 4.4 kg and 61.2 ± 3.1 kg, respectively). The variables comprised three agility tests: a 20-yard test, a T-test and the Illinois test, all performed in both specific and non-specific conditions. Between-subject and within-subject reliability were found to be high (Cronbach Alpha: 0.93 to 0.98; Coefficient of Variation: 3 to 8%), with better within-subject reliability and stability of the measurement for specific tests. Pearson’s product moment correlations between the non-specific and specific agility performances were high (r ≥0.84), while factor analysis extracted only one significant latent dimension on the basis of the Guttman-Kaiser criterion. The results of the 20-yard test were better when the test was conducted in the specific conditions (t-test = 2.66; p < 0.05). For the Illinois test, superior results were recorded in the non-specific conditions (t-test = 2.96; p < 0.05), which can be explained by the test duration (about 20 s) and non-specific locomotion forms such as rotational movements. Considering the findings of the present study, when testing tennis-specific pre-planned agility, we suggest using tests of short duration (less than 10 s) and sport-specific types of locomotion. PMID:28210343

  18. Human blood group typing based on digital photographs of RBC agglutination process

    NASA Astrophysics Data System (ADS)

    Doubrovski, V. A.; Dolmashkin, A. A.

    2010-08-01

    A method for the monitoring of the human erythrocyte agglutination reaction in vitro, which is the basis for determining the human blood type (group), is proposed. The method is based on a statistical analysis of digital photographs of the agglutination process. It is experimentally shown that this analysis of photographs makes it possible to determine the probability that the agglutination reaction of erythrocytes of the studied specimen of blood with corresponding isohemagglutinating sera does occur. To increase the rate of the agglutination reaction of erythrocytes and to improve the sensitivity of the method of monitoring, the bioobject under study is subjected to the action of ultrasonic waves, as was previously proposed by the authors, and the result of the erythrocyte agglutination reaction is read optically. It is shown that, in principle, the method of statistical processing of digital photographs can be used to develop devices for automatic human blood typing in the AB0 and Rh systems.

  19. Sperm-agglutinating antibodies and testicular morphology in fifty-nine men with azoospermia or cryptozoospermia.

    PubMed

    Friberg, J; Kjessler, B

    1975-04-01

    The relationship between the state of the germinal epithelium and the type and titer of circulating sperm-agglutinating antibodies has been investigated in a series of 59 azoospermic or occasionally cryptozoospermic men. The patients were grouped according to the condition of the germinal epithelium as observed from testicular biopsy specimens, as well as to type and titer of circulating sperm-agglutinating antibodies investigated by a previously described microagglutination technique. Evidence is presented to suggest that the presence of mature spermatozoa in the testicular structures may be a prerequisite for the spontaneous production of circulating sperm-agglutinating antibodies, at least of the head-to-tail (H-T) agglutinating type. Furthermore, these circulating H-T sperm-agglutinating antibodies, once they are formed, do not seem to interfere adversely with the germinal epithelium of the carrier.

  20. End User Acceptance - Requirements or Specifications, Certification, Testing

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith

    2013-01-01

    NASA follows top level safety requirement of two-failure tolerance (t hree levels of controls or design for minimum risk) to all catastroph ic hazards in the design of safe li-ion batteries for space use. ? R igorous development testing at appropriate levels to credible offnominal conditions and review of test data. ? Implement robust design con trols based on test results and test again to confirm safety at the a ppropriate levels. ? Stringent testing of all (100%) flight batteries (from button cells to large batteries).

  1. Red blood cell membrane viscoelasticity, agglutination and zeta potential measurements with double optical tweezers

    NASA Astrophysics Data System (ADS)

    Fontes, Adriana; Fernandes, Heloise P.; Barjas-Castro, Maria L.; de Thomaz, André A.; de Ysasa Pozzo, Liliana; Barbosa, Luiz C.; Cesar, Carlos L.

    2006-02-01

    The red blood cell (RBC) viscoelastic membrane contains proteins and glycolproteins embedded in, or attached, to a fluid lipid bilayer and are negatively charged, which creates a repulsive electric (zeta) potential between the cells and prevents their aggregation in the blood stream. There are techniques, however, to decrease the zeta potential to allow cell agglutination which are the basis of most of the tests of antigen-antibody interactions in blood banks. This report shows the use of a double optical tweezers to measure RBC membrane viscosity, agglutination and zeta potential. In our technique one of the optical tweezers trap a silica bead that binds strongly to a RBC at the end of a RBCs rouleaux and, at the same time, acts as a pico-Newton force transducer, after calibration through its displacement from the equilibrium position. The other optical tweezers trap the RBC at the other end. To measure the membrane viscosity the optical force is measured as a function of the velocity between the RBCs. To measure the adhesion the tweezers are slowly displaced apart until the RBCs disagglutination happens. The RBC zeta potential is measured in two complimentary ways, by the force on the silica bead attached to a single RBC in response to an applied electric field, and the conventional way, by the measurement of terminal velocity of the RBC after released from the optical trap. These two measurements provide information about the RBC charges and, also, electrolytic solution properties. We believe this can improve the methods of diagnosis in blood banks.

  2. Content Specifications of a Test and Generalizability Theory.

    ERIC Educational Resources Information Center

    Gonzalez-Tamayo, Eulogio

    The concepts of universe of admissible observation and universe of generalization from the generalizability theory were applied to calculate the intraclass correlation coefficient of a licensure test. The internal consistency coefficient of a dichotomously scored test is identical to the intraclass correlation coefficient of a two-facet design.…

  3. 30 CFR 7.86 - Test equipment and specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 7.86 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING...-3.2 (3) The test fuel temperature at the inlet to the diesel engine's fuel injection pump shall be... and V12; (x) Heated Flow Control Valves—V14 and V18; (xi) Pump—Sample Transfer Pump; (xii)...

  4. Sensory-specific satiation with a pinched nose and eyes closed: testing the sensory modality specificity of satiation.

    PubMed

    Havermans, Remco C; Mallach, Anna-Theresa

    2014-02-01

    Sensory-specific satiation refers to the decrease in pleasantness derived from a consumed food relative to other unconsumed foods. In the current study, it was investigated to what extent sensory-specific satiation is modality specific. To this end, 80 female participants ate a preferred snack until full while wearing (or not wearing) a blindfold and/or a nose clip. Impaired vision should impede satiation for the appearance of the consumed test snack. Obstructing olfaction should undermine satiation for the smell of the test snack. Indeed, when vision was obstructed, hedonic ratings of specifically snack appearance did not decrease as much. When olfaction was blocked, the hedonic ratings for the flavor of the test snack did not show as much of a reduction. It is concluded that, to a degree, sensory-specific satiation is indeed modality specific.

  5. Immunoreactions involving platelets. III. Quantitative aspects of platelet agglutination, inhibition of clot retraction, and other reactions caused by the antibody of quinidine purpura.

    PubMed

    SHULMAN, N R

    1958-05-01

    Quantitative aspects of platelet agglutination and inhibition of clot retraction by the antibody of quinidine purpura were described. The reactions appeared to depend on formation of types of antibody-quinidine-platelet complexes which could fix complement but complement was not necessary for these reactions. Complement fixation was at least 10 times more sensitive than platelet agglutination or inhibition of clot retraction for measurement and detection of antibody activity. Although it has been considered that antibodies of drug purpura act as platelet lysins in the presence of complement and that direct lysis of platelets accounts for development of thrombocytopenia in drug purpura, the present study suggests that attachment of antibody produces a change in platelets which is manifested in vitro only by increased susceptibility to non-specific factors which can alter the stability of platelets in the absence of antibody. The attachment of antibody to platelets in vivo may only indirectly affect platelet survival. In contrast to human platelets, dog, rabbit, and guinea pig platelets, and normal or trypsin-treated human red cells did not agglutinate, fix complement, or adsorb antibody; and intact human endothelial cells did not fix complement or adsorb antibody. Rhesus monkey platelets were not agglutinated by the antibody but did adsorb antibody and fix complement although their activity in these reactions differed quantitatively from that of human platelets. Cinchonine could be substituted for quinidine in agglutination and inhibition of clot retraction reactions but quinine and cinchonidine could not. Attempts to cause passive anaphylaxis in guinea pigs with the antibody of quinidine purpura were not successful.

  6. 46 CFR 71.20-20 - Specific tests and inspections.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) For inspection procedures of marine engineering equipment and systems, see subchapter F (Marine Engineering) of this chapter. (d) For inspection procedures of electrical engineering equipment and systems, see subchapter J (Electrical Engineering) of this chapter. (e) For inspection and testing standards...

  7. 46 CFR 126.350 - Specific tests and inspections.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Installation of piping for gaseous fixed fire-extinguishing (see § 95.15-15 of this chapter). (2) Hydraulic steering-systems. If fitted with manual operation, these systems must be tested in the manual mode, with the hydraulic pumps secured, for smooth, efficient operation by one person....

  8. 46 CFR 71.20-20 - Specific tests and inspections.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) For inspection procedures of marine engineering equipment and systems, see subchapter F (Marine Engineering) of this chapter. (d) For inspection procedures of electrical engineering equipment and systems, see subchapter J (Electrical Engineering) of this chapter. (e) For inspection and testing standards...

  9. 40 CFR 798.5200 - Mouse visible specific locus test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... distilled water or isotonic saline buffered appropriately, if needed, for stability. Water-insoluble..., inhalation, admixture with food or water, and IP or IV injections. (e) Test performance—(1) Treatment and... of data for exposed spermatagonial stem cells thereafter. Repeated mating cycles should be...

  10. Testing a Model of Caffeinated Alcohol-specific Expectancies

    PubMed Central

    Linden-Carmichael, Ashley N.; Lau-Barraco, Cathy; Stamates, Amy L.

    2015-01-01

    Introduction The present study sought to further understand the association between caffeinated alcoholic beverage (CAB) use and alcohol-related risks. In particular, we focused on the role of two identified expectancies specific to CAB use: intoxication enhancement and avoidance of negative consequences. Although outcome expectancies are consistent predictors of substance use, limited research has examined expectancies related to CAB use and their association with alcohol-related behaviors, such as protecting themselves from alcohol-related harms. Consequently, the present study examined CAB-specific expectancies and protective behavioral strategies (PBS) as mediators of CAB use and negative consequences. Methods Participants were 322 (219 women) college drinkers who completed self-report measures of typical CAB and alcohol use, CAB-specific expectancies, PBS use, and alcohol-related harms. Results Structural equation modeling revealed, after controlling for typical non-CAB heavy alcohol use, a significant indirect effect of CAB use to alcohol-related problems through avoidance of negative consequences CAB expectancies and PBS use. However, intoxication enhancement expectancies did not mediate this association. Conclusions Thus, our findings indicate that heavier CAB use was associated with stronger expectations that drinking CABs can help avoid negative consequences. These beliefs were related to using fewer PBS when drinking and a greater likelihood of experiencing problems. Given that these expectancies may be underlying mechanisms of CAB use, their inclusion in existing alcohol interventions may be beneficial. PMID:25864133

  11. Specification of Surface Roughness for Hydraulic Flow Test Plates

    SciTech Connect

    Donna Post Guillen; Timothy S. Yoder

    2006-05-01

    A study was performed to determine the surface roughness of the corrosion layer on aluminum clad booster fuel plates for the proposed Gas Test Loop (GTL) system to be incorporated into the Advanced Test Reactor (ATR) at the Idaho National Laboratory. A layer of boehmite (a crystalline, non-porous gamma-alumina hydrate) is typically pre-formed on the surface of the fuel cladding prior to exposure to reactor operation to prevent the uncontrolled buildup of corrosion product on the surface. A representative sample coupon autoclaved with the ATR driver fuel to produce the boehmite layer was analyzed using optical profilometry to determine the mean surface roughness, a parameter that can have significant impact on the coolant flow past the fuel plates. This information was used to specify the surface finish of mockup fuel plates for a hydraulic flow test model. The purpose of the flow test is to obtain loss coefficients describing the resistance of the coolant flow paths, which are necessary for accurate thermal hydraulic analyses of the water-cooled booster fuel assembly. It is recommended that the surface roughness of the boehmite layer on the fuel cladding be replicated for the flow test. While it is very important to know the order of magnitude of the surface roughness, this value does not need to be matched exactly. Maintaining a reasonable dimensional tolerance for the surface finish on each side of the 12 mockup fuel plates would ensure relative uniformity in the flow among the four coolant channels. Results obtained from thermal hydraulic analyses indicate that ±15% deviation from a surface finish (i.e., Ra) of 0.53 ìm would have a minimal effect on coolant temperature, coolant flow rate, and fuel temperature.

  12. ORNL testing of DOT specification 17H drums (55-gallon) for compliance with DOT specifications for Type A packaging

    SciTech Connect

    Baldwin, J.S.; Lasher, L.C.; Van Cleve, J.E. Jr.; Van Hoesen, S.D.

    1986-07-01

    Oak Ridge National Laboratory (ORNL) proposes using Department of Transportation (DOT) specification 17H drums (55-gal) for transporting low-level waste (LLW) to Oak Ridge Gaseous Diffusion Plant (ORGDP) for interim storage. This container type was tested and found to be in compliance with DOT specifications for Type A packaging.

  13. 40 CFR 86.1375-2007 - Equipment specifications for field testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Equipment specifications for field... Exhaust Test Procedures § 86.1375-2007 Equipment specifications for field testing. For testing conducted with engines installed in vehicles, including field testing conducted to measure emissions under...

  14. 40 CFR 86.1375-2007 - Equipment specifications for field testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Equipment specifications for field... Exhaust Test Procedures § 86.1375-2007 Equipment specifications for field testing. For testing conducted with engines installed in vehicles, including field testing conducted to measure emissions under...

  15. 40 CFR 86.1375-2007 - Equipment specifications for field testing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Equipment specifications for field... Exhaust Test Procedures § 86.1375-2007 Equipment specifications for field testing. For testing conducted with engines installed in vehicles, including field testing conducted to measure emissions under...

  16. 40 CFR 86.1375-2007 - Equipment specifications for field testing.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Equipment specifications for field... Exhaust Test Procedures § 86.1375-2007 Equipment specifications for field testing. For testing conducted with engines installed in vehicles, including field testing conducted to measure emissions under...

  17. Increasing the specificity of the forensic luminol test for blood.

    PubMed

    Quickenden, T I; Cooper, P D

    2001-01-01

    It is shown that the presumptive luminol chemiluminescence test for the presence of traces of blood can be made more determinative by measuring the peak emission wavelength of the luminol chemiluminescence. When sprayed onto a surface containing traces of human haemoglobin, a 1 g/L solution of aqueous luminol containing 7 g/L sodium perborate gives an emission peak at 455 +/- 2 nm, whereas the same mixture gives an emission peak at 430 +/- 3 nm when sprayed onto a surface containing traces of sodium hypochlorite (household bleach). This spectral difference can readily be determined using spectroscopic equipment that either scans the spectrum before significant luminescence decay occurs or corrects the spectrum for the effects of any decay. It was found that bovine haemoglobin and human haemoglobin showed no significant spectral differences.

  18. Specification and testing for power by wire aircraft

    NASA Astrophysics Data System (ADS)

    Hansen, Irving G.; Kenney, Barbara H.

    1993-08-01

    A power by wire aircraft is one in which all active functions other than propulsion are implemented electrically. Other nomenclature are 'all electric airplane,' or 'more electric airplane.' What is involved is the task of developing and certifying electrical equipment to replace existing hydraulics and pneumatics. When such functions, however, are primary flight controls which are implemented electrically, new requirements are imposed that were not anticipated by existing power system designs. Standards of particular impact are the requirements of ultra-high reliability, high peak transient bi-directional power flow, and immunity to electromagnetic interference and lightning. Not only must the electromagnetic immunity of the total system be verifiable, but box level tests and meaningful system models must be established to allow system evaluation. This paper discusses some of the problems, the system modifications involved, and early results in establishing wiring harness and interface susceptibility requirements.

  19. Insights into the Antimicrobial Mechanism of Action of Human RNase6: Structural Determinants for Bacterial Cell Agglutination and Membrane Permeation

    PubMed Central

    Pulido, David; Arranz-Trullén, Javier; Prats-Ejarque, Guillem; Velázquez, Diego; Torrent, Marc; Moussaoui, Mohammed; Boix, Ester

    2016-01-01

    Human Ribonuclease 6 is a secreted protein belonging to the ribonuclease A (RNaseA) superfamily, a vertebrate specific family suggested to arise with an ancestral host defense role. Tissue distribution analysis revealed its expression in innate cell types, showing abundance in monocytes and neutrophils. Recent evidence of induction of the protein expression by bacterial infection suggested an antipathogen function in vivo. In our laboratory, the antimicrobial properties of the protein have been evaluated against Gram-negative and Gram-positive species and its mechanism of action was characterized using a membrane model. Interestingly, our results indicate that RNase6, as previously reported for RNase3, is able to specifically agglutinate Gram-negative bacteria as a main trait of its antimicrobial activity. Moreover, a side by side comparative analysis with the RN6(1–45) derived peptide highlights that the antimicrobial activity is mostly retained at the protein N-terminus. Further work by site directed mutagenesis and structural analysis has identified two residues involved in the protein antimicrobial action (Trp1 and Ile13) that are essential for the cell agglutination properties. This is the first structure-functional characterization of RNase6 antimicrobial properties, supporting its contribution to the infection focus clearance. PMID:27089320

  20. The Cenozoic Diversity of Agglutinated Foraminifera - Evidence for a late Oligocene to early Miocene diversification event

    NASA Astrophysics Data System (ADS)

    Kaminski, Michael; Setoyama, Eiichi; Kender, Sev; Cetean, Claudia

    2014-05-01

    The agglutinated foraminifera are among the most abundant micro-organisms in the deep marine environment and have a diversity record extending back to the late Precambrian. We present an updated diversity curve for agglutinated foraminiferal genera based on the stratigraphic ranges of all the agglutinated genera recognized as valid in the classification of Kaminski (2014). The data set for this analysis is based on the stratigraphic ranges of agglutinated genera published in Foraminiferal Genera and their Classification, which has been subsequently updated based on published studies and our new observations. The mean standing diversity of agglutinated foraminiferal genera was compiled by counting the number of boundary crossers rather than the number of genera in each stage. In this study, we report the stratigraphic and geographical occurrence of a benthic foraminiferal diversification event that has previously received little attention. In the latest Oligocene to earliest Miocene a number of trochospiral agglutinated genera with alveolar or canaliculate walls first appeared in the fossil record. Our studies of late Oligocene of the Congo fan, offshore Angola (Kender et al., 2008; Cetean and Kaminski, 2011) have revealed a diverse assemblage that includes new taxa of deep-water agglutinated foraminifera. In a biostratigraphic study of the Miocene foraminiferal assemblages Kender et al. (2008) noted steadily increasing diversity and proportions of infaunal agglutinated foraminiferal morphotypes over the lower Miocene interval. The proportion of infaunal agglutinated foraminifera assigned to the order Textularida increased dramatically in the lower mid-Miocene, suggesting expansion of the oxygen minimum zone into deeper waters. In addition to the trochospiral alveolar genera, several species of Reticulophragmium and Cyclammina display rapid diversification into numerous separate lineages that are at present not reflected in our generic diversity record owing to

  1. Use of the protective antigen of Erysipelothrix rhusiopathiae in the enzyme-linked immunosorbent assay and latex agglutination.

    PubMed

    Sato, H; Yamazaki, Y; Tsuchiya, K; Aoyama, T; Akaba, N; Suzuki, T; Yokoyama, A; Saito, H; Maehara, N

    1998-09-01

    To establish a safe and convenient serodiagnostic method for swine erysipelas, a purified protective protein antigen of Erysipelothrix rhusiopathiae, which included a large amount of protective protein (64 kDa protein), was used for enzyme-linked immunosorbent assay (ELISA) and the latex agglutination (LA) test. In the ELISA, the antisera to four different serovars (1a, 2, 5 and 20) of E. rhusiopathiae exhibit a positive reaction, while antisera to other species of bacteria (Listeria monocytogenes, Staphylococcus aureus, Streptococcus suis, Rhodococcus equi and Corynebacterium pseudotuberculosis) exhibit a negative reaction. In the LA test, the antisera to three different serovars (1a, 2 and 5) of E. rhusiopathiae reacted with P64-sensitized latex beads, while the antiserum to serovar 20 (2553 strain) did not. Moreover, the antisera to other species of bacteria (Listeria monocytogenes, Staphylococcus aureus, Streptococcus suis, Rhodococcus equi and Corynebacterium pseudotuberculosis) did not in this test. Comparing the results of the growth agglutination (GA), ELISA and LA tests of 284 swine sera, there was a high degree of correlation among the results. The detection of anti-E. rhusiopathiae antibodies in the GA, ELISA and LA tests were compared using sera from pigs immunized with P64, alkaline extract (AE) and live-cell vaccine (LV). In all three tests, anti-E. rhusiopathiae antibodies could be detected 1 week after immunization. The serum antibody titre as determined by the LA test increased moderately, as did that by the GA test, while that determined by ELISA increased rapidly. These results suggested that ELISA could be used to monitor changes in anti-E. rhusiopathiae antibody titre and the LA test could be used in the screening test for swine erysipelas.

  2. Modulation of ligand-mediated human red cell agglutinability by prostaglandins

    SciTech Connect

    McLawhon, R.W.; Marikovsky, Y.; Weinstein, R.S.

    1986-03-01

    Ethanol induces the transformation of human red cells from bioconcave discs to echinocytes in vitro. In addition, they have observed that ethanol can enhance the agglutination of red cells by the plant lectin wheat germ agglutinin or poly-L-lysine. Incubation of washed human red cells with 5 and 10% ethanol (v/v) in phosphate buffered saline, pH 7.3 at 25/sup 0/C produced a 30% increase in ligand-mediated agglutinability within 12 min. Simultaneous addition of ethanol and one of the following prostaglandin derivatives, PGE/sub 1/, pge/sub 2/, pgf/sub 2/-alpha, or PGl/sub 2/ (10/sup -9/ to 5 x 10/sup -7/ M) prevented the shape-associated increases in red cell agglutinability. Thromboxane-B/sub 2/ had no effect on agglutinability. Prostaglandins did not prevent ethanol-induced red cell shape transformations per se under identical experimental conditions. As intragastric administration of 100% ethanol results in the formation of spiculated red cell thrombi in postcapillary venules of rat gastric mucosa, they postulate that the cytoprotective role of prostanoids in preventing mucosal ulceration may be due in part to their capacity to inhibit intravascular ligand mediated red cell agglutination, hemostasis, and their sequelae, epithelial necrosis. Moreover, the data suggest that ethanol-induced red cell shape transformations and ligand-mediated agglutination represent two distinct and independent biological phenomena.

  3. 21 CFR 866.5550 - Immunoglobulin (light chain specific) immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Immunoglobulin (light chain specific) immunological test system. 866.5550 Section 866.5550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Test Systems § 866.5550 Immunoglobulin (light chain specific) immunological test system....

  4. 21 CFR 866.5550 - Immunoglobulin (light chain specific) immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Immunoglobulin (light chain specific) immunological test system. 866.5550 Section 866.5550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Test Systems § 866.5550 Immunoglobulin (light chain specific) immunological test system....

  5. 21 CFR 866.5550 - Immunoglobulin (light chain specific) immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Immunoglobulin (light chain specific) immunological test system. 866.5550 Section 866.5550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Test Systems § 866.5550 Immunoglobulin (light chain specific) immunological test system....

  6. 21 CFR 866.5550 - Immunoglobulin (light chain specific) immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Immunoglobulin (light chain specific) immunological test system. 866.5550 Section 866.5550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Test Systems § 866.5550 Immunoglobulin (light chain specific) immunological test system....

  7. Proceedings of the Advisory Committee on Standardization of Carbon-Phenolic Test Methods and Specifications

    SciTech Connect

    Hall, W.B.

    1990-04-01

    Topics addressed include: Polyacrylonitrile (PAN) activity; low fired PAN fiber program review; carbon fabric oxidation mass loss; gel permeation chromatography (GPC) test methodology; carbon assay testing; and NAR rayon yarn specifications.

  8. Comparison of counter-immunoelectrophoresis with other serological tests in the diagnosis of human brucellosis

    PubMed Central

    Díaz, R.; Maravi-Poma, E.; Rivero, A.

    1976-01-01

    Sera from 65 persons with clinical brucellosis were employed in a comparison of standard and rapid serological tests. The results obtained with the Rose Bengal test correlated very well with those of the standard tube agglutination test, whereas results with the rapid plate agglutination test and the Coombs (antiglobulin) test were inferior. Absorption of patients' sera with specific anti-human immunoglobulin sera showed that IgM was active in the Rose Bengal test but not in the Coombs test, whereas IgG and IgA were active in both tests. In addition to the A & M antigen, which plays the most important role in the agglutination, Rose Bengal, and Coombs tests, other antigenic fractions of Brucella were examined in precipitation tests. A protein antigen reacted with 94% of the sera in counter-immunoelectrophoresis. On the basis of the results with both groups of sera, the Rose Bengal test and counter-immunoelectrophoresis appear to be the most promising methods for diagnosing clinical brucellosis. The tests differ qualitatively since different Brucella antigens are employed. PMID:791532

  9. Evaluation of Four Whole-Cell Leptospira-Based Serological Tests for Diagnosis of Urban Leptospirosis▿

    PubMed Central

    McBride, Alan J. A.; Santos, Balbino L.; Queiroz, Adriano; Santos, Andréia C.; Hartskeerl, Rudy A.; Reis, Mitermayer G.; Ko, Albert I.

    2007-01-01

    Four serologic assays for leptospirosis had sensitivities of 72 to 88% and specificities of 88 to 100% in the setting of highly endemic urban transmission, indicating that assays using enzyme-linked immunosorbency and rapid formats may be used as alternatives to the microscopic agglutination test for diagnosing urban leptospirosis. Testing a second sample will be required in cases with an initial negative result, since sensitivity was low (46 to 68%) during the first week of illness. PMID:17652521

  10. Evaluating Specification Tests in the Context of Value-Added Estimation

    ERIC Educational Resources Information Center

    Guarino, Cassandra M.; Reckase, Mark D.; Stacy, Brian W.; Wooldridge, Jeffrey M.

    2015-01-01

    We study the properties of two specification tests that have been applied to a variety of estimators in the context of value-added measures (VAMs) of teacher and school quality: the Hausman test for choosing between student-level random and fixed effects, and a test for feedback (sometimes called a "falsification test"). We discuss…

  11. Evaluating Specification Tests in the Context of Value-Added Estimation. Working Paper #38

    ERIC Educational Resources Information Center

    Guarino, Cassandra M.; Reckase, Mark D.; Stacy, Brian W.; Wooldridge, Jeffrey M.

    2014-01-01

    We study the properties of two specification tests that have been applied to a variety of estimators in the context of value-added measures (VAMs) of teacher and school quality: the Hausman test for choosing between random and fixed effects and a test for feedback (sometimes called a "falsification test"). We discuss theoretical…

  12. Prevalence of agglutinating antibodies to Sarcocystis neurona in skunks (Mephitis Mephitis), raccoons (Procyon lotor), and opossums (Didelphis Virginiana) from Connecticut.

    PubMed

    Mitchell, Sheila M; Richardson, Dennis J; Cheadle, M Andy; Zajac, Anne M; Lindsay, David S

    2002-10-01

    Equine protozoal myeloencephalitis is the most important protozoan disease of horses in North America and is usually caused by Sarcocystis neurona. Natural cases of encephalitis caused by S. neurona have been reported in skunks (Mephitis mephitis) and raccoons (Procyon lotor). Opossums (Didelphis spp.) are the only known definitive host. Sera from 24 striped skunks, 12 raccoons, and 7 opossums (D. virginiana) from Connecticut were examined for agglutinating antibodies to S. neurona using the S. neurona agglutination test (SAT) employing formalin-fixed merozoites as antigen. The SAT was validated for skunk sera using pre- and postinfection serum samples from 2 experimentally infected skunks. Of the 24 (46%) skunks 11 were positive, and all 12 raccoons were positive for S. neurona antibodies. None of the 7 opossums was positive for antibodies to S. neurona. These results suggest that exposure to sporocysts of S. neurona by intermediate hosts is high in Connecticut. The absence of antibodies in opossums collected from the same areas is most likely because of the absence of systemic infection in the definitive host.

  13. Interaction of bacterial endotoxine (lipopolysaccharide) with latex particles: application to latex agglutination immunoassays.

    PubMed

    Peula-García, J M; Molina-Bolivar, J A; Velasco, J; Rojas, A; Galisteo-González, F

    2002-01-15

    The latex agglutination immunoassay technique uses polymer colloids as carriers for antibodies or antigens to enhance the immunological reaction. In this work, the interaction of a lipopolysaccharide (LPS) of Brucella Melitensis with two conventional latexes has been studied. Some experiments on the physical adsorption of the LPS onto these polystyrene beads have been performed and several complexes with different coverage degrees were obtained by modifying the incubation conditions. Regarding the application in the development of diagnostic test systems, it is advisable to study the latex-LPS complexes from an electrokinetic and colloidal stability point of view. The complexes were electrokinetically characterized by measuring the electrophoretic mobility under different redispersion conditions. The colloidal stability was determined by simple turbidity measurements. Experimental and theoretical data have been employed to study the molecular disposition of the LPS in the latex particle surface to compare with the outer membrane of bacterial cells. Latex complexes covered by different LPS amounts showed high colloidal stability and adequate immunoreactivity that remains for a long time period.

  14. Reading development in agglutinative languages: evidence from beginning, intermediate, and adult Basque readers.

    PubMed

    Acha, Joana; Laka, Itziar; Perea, Manuel

    2010-04-01

    Do typological properties of language, such as agglutination (i.e., the morphological process of adding affixes to the lexeme of a word), have an impact on the development of visual word recognition? To answer this question, we carried out an experiment in which beginning, intermediate, and adult Basque readers (n=32 each, average age=7, 11, and 22 years, respectively) needed to read correctly versus incorrectly inflected words embedded in sentences. Half of the targets contained high-frequency stems, and the other half contained low-frequency stems. To each stem, four inflections of different lengths were attached (-a, -ari, -aren, and -arentzat, i.e., inflectional sequences). To test whether the process of word recognition was modulated by the knowledge of word structure in the language, half of the participants' native language was Basque and the other half's native language was Spanish. Children showed robust effects of frequency and length of inflection that diminished with age. In addition, the effect of length of inflection was modulated by the frequency of the stem and by the native language. Taken together, these results suggest that word recognition develops from a decoding strategy to a direct lexical access strategy and that this process is modulated by children's knowledge of the inflectional structure of words from the beginning of their reading experience.

  15. Validity of a squash-specific test of multiple-sprint ability.

    PubMed

    Wilkinson, Michael; McCord, Andrew; Winter, Edward M

    2010-12-01

    We examined the validity and reproducibility of a squash-specific multiple-sprint test. Eight male squash and 8 male soccer players performed Baker's 8 × 40-m sprints and a squash-specific-multiple-sprint test on separate days. The sum of individual sprint times in each test was recorded. Six squash and 6 soccer players repeated the tests 7 days later to assess reproducibility using intraclass correlation. In addition, 2 England Squash coaches independently ranked the squash players using knowledge of the player and recent performances in local leagues. Performance on the squash-specific (r = 0.97 and 0.90) and Baker's test (r = 0.95 and 0.83) was reproducible in squash and soccer players, respectively, and did not differ on Baker's test (mean ± SD 72.9 ± 3.9 and 72.9 ± 2.8 seconds for squash and soccer players, p = 0.969, effect size = 0.03). Squash players (232 ± 32 seconds) outperformed soccer players (264 ± 14 seconds) on the squash-specific test (p = 0.02, effect size = 1.39). Performance on Baker's and the squash-specific test were related in squash players (r = 0.98, p < 0.001) but not in soccer players (r = -0.08, p = 0.87). Squash-player rank correlated with performance on the squash-specific (ρ = 0.79, p = 0.02) but not the Baker's test (ρ = 0.55, p = 0.16). The squash-specific test discriminated between groups with similar non-sport-specific multiple-sprint ability and in squash players. In conjunction with the relationship between test performances, the results suggest that the squash-specific test is a valid and reproducible measure of multiple-sprint ability in squash players and could be used for assessing and tracking training-induced changes in multiple-sprint ability.

  16. 49 CFR 180.509 - Requirements for inspection and test of specification tank cars.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Requirements for inspection and test of... Requirements for inspection and test of specification tank cars. (a) General. Each tank car owner must ensure that a tank car facility: (1) Inspects and tests each item according to the requirements specified...

  17. 49 CFR 180.509 - Requirements for inspection and test of specification tank cars.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Requirements for inspection and test of... Requirements for inspection and test of specification tank cars. (a) General. Each tank car owner must ensure that a tank car facility: (1) Inspects and tests each item according to the requirements specified...

  18. 49 CFR 180.509 - Requirements for inspection and test of specification tank cars.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Requirements for inspection and test of... Requirements for inspection and test of specification tank cars. (a) General. Each tank car owner must ensure that a tank car facility: (1) Inspects and tests each item according to the requirements specified...

  19. 49 CFR 180.509 - Requirements for inspection and test of specification tank cars.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... metal jacket or with a thermal protection system shall have an inspection and test conforming to this... 49 Transportation 3 2011-10-01 2011-10-01 false Requirements for inspection and test of... Requirements for inspection and test of specification tank cars. (a) General. (1) Each tank car facility...

  20. Standard Setting in Specific-Purpose Language Testing: What Can a Qualitative Study Add?

    ERIC Educational Resources Information Center

    Manias, Elizabeth; McNamara, Tim

    2016-01-01

    This paper explores the views of nursing and medical domain experts in considering the standards for a specific-purpose English language screening test, the Occupational English Test (OET), for professional registration for immigrant health professionals. Since individuals who score performances in the test setting are often language experts…

  1. Negative and Positive Testing Effects in Terms of Item-Specific and Relational Information

    ERIC Educational Resources Information Center

    Mulligan, Neil W.; Peterson, Daniel J.

    2015-01-01

    Though retrieving information typically results in improved memory on a subsequent test (the testing effect), Peterson and Mulligan (2013) outlined the conditions under which retrieval practice results in poorer recall relative to restudy, a phenomenon dubbed the "negative testing effect." The item-specific-relational account proposes…

  2. 21 CFR 866.5520 - Immunoglobulin G (Fab fragment specific) immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) immunological test system. 866.5520 Section 866.5520 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test Systems § 866.5520 Immunoglobulin G (Fab fragment specific) immunological test system....

  3. 21 CFR 866.5520 - Immunoglobulin G (Fab fragment specific) immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) immunological test system. 866.5520 Section 866.5520 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test Systems § 866.5520 Immunoglobulin G (Fab fragment specific) immunological test system....

  4. Helicobacter pylori TlyA agglutinates liposomes and induces fusion and permeabilization of the liposome membranes.

    PubMed

    Lata, Kusum; Chattopadhyay, Kausik

    2014-06-10

    Helicobacter pylori TlyA is a pore-forming hemolysin with potent cytotoxic activity. To explore the potential membrane-damaging activity of H. pylori TlyA, we have studied its interaction with the synthetic liposome vesicles. In our study, H. pylori TlyA shows a prominent ability to associate with the liposome vesicles without displaying an obligatory requirement for any protein receptor on the liposome membranes. Interaction of TlyA triggers agglutination of the liposome vesicles. Such agglutinating activity of TlyA could also be observed with erythrocytes before the induction of its pore-forming hemolytic activity. In addition to its agglutinating activity against liposomes, TlyA also induces fusion and disruption of the liposome membranes. Altogether, our study highlights novel membrane-damaging properties of H. pylori TlyA that have not been documented previously with any other TlyA family protein.

  5. SUPPRESSION OF BLOOD GROUP AGGLUTINABILITY OF HUMAN ERYTHROCYTES BY CERTAIN BACTERIAL POLYSACCHARIDES

    PubMed Central

    Ceppellini, Ruggero; Landy, Maurice

    1963-01-01

    Erythrocytes coated with bacterial capsular polysaccharides, notably the Vi antigen, were no longer agglutinated by antibodies directed against the various antigens native to the red cell surface. These effects could not be attributed to prevention of antibody uptake even though in some systems the uptake of antibody was diminished. In fact, agglutination by Rh-incomplete antibody was brought back to the original titer only after the sensitized Vi-coated cells had been subjected to ten alternating exposures to globulin and antiglobulin. Hemagglutination by Newcastle, mumps, and influenza viruses was also suppressed. Erythrocytes coated with Vi polysaccharide assumed the distinctive physicochemical attributes of this acidic polymer which results in a stabilization of the erythrocyte suspension as manifested by increased electrophoretic mobility and a striking decrease in the rate of sedimentation. Among the possible models for explaining the nature of the Vi effect on immune agglutination, the data favor interference with lattice formation. PMID:14019651

  6. Development of a force specification for a force-limited random vibration test

    SciTech Connect

    Stevens, R.R.

    1996-02-01

    Vibration testing, techniques have been developed and employed that reduce the overtesting caused by the essentially infinite mechanical impedance of the shaker in conventional vibration tests. With these ``force-limiting`` techniques, two vibration test specifications are used: the conventional acceleration specification, and an interface force specification. The vibration level of the shake table is controlled such that neither the table acceleration nor the force transmitted to the test item exceeds its specification, hence the name ``dual control`` vibration test. The effect of limiting the shake table vibration to the force specification is to reduce (``notch``) the shaker acceleration near some of the test item`s resonance frequencies. Several methods of deriving the force specification have been described in the literature. A new method is proposed in this paper that is based on a modal method of coupling two dynamic systems, in this case the ``source`` or launch vehicle, and the ``load`` or payload. The only information that is required is an experimentally-measurable frequency-response function (FRF) called the dynamic mass for both the source and the load. The method, referred to as the coupled system, modal approach (CSMA) method, is summarized and compared to an existing method of determining the force specification for force-limited vibration testing.

  7. Project W-314 specific test and evaluation plan for AZ tank farm upgrades

    SciTech Connect

    Hays, W.H.

    1998-08-12

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made by the addition of the SN-631 transfer line from the AZ-O1A pit to the AZ-02A pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation P1 an (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities, etc), Factory Tests and Inspections (FTIs), installation tests and inspections, Construction Tests and Inspections (CTIs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). The STEP will be utilized in conjunction with the TEP for verification and validation.

  8. Testing Requirements to Manage Data Exchange Specifications in Enterprise Integration - A Schema Design Quality Focus.

    SciTech Connect

    Kulvatunyou, Boonserm; Ivezic, Nenad; Buhwan, Jeong

    2004-07-01

    In this paper, we describe the requirements to test W3C XML Schema usage when defining message schemas for data exchange in any large and evolving enterprise integration project. We then decompose the XML Schema testing into four (4) aspects including the message schema conformance to the XML Schema specification grammar, the message schema conformance to the XML Schema specification semantics, the message schema conformance to design quality testing, and canonical semantics testing of the message schema. We describe these four testing aspects in some detail and point to other related efforts. We further focus to provide some technical details for the message schema design quality testing. As a future work, we describe the requirements for canonical semantics testing and potential solution approaches. Finally, we describe an implementation architecture for the message schema design quality testing.

  9. Agglutinates as recorders of fossil soil compositions. [of Apollo 17 lunar probes

    NASA Technical Reports Server (NTRS)

    Taylor, G. J.; Wentworth, S.; Warner, R. D.; Keil, K.

    1978-01-01

    The composition of agglutinates in polished sections of the Apollo 17 drill core was studied in an attempt to deduce the nature of the Taurus-Littrow valley regolith prior to the formation of the Camelot and Central Cluster craters. The agglutinate compositions in the soils differed from the host soil compositions except for samples from the North Massif. Local materials from the valley floor and the massifs appear to form the pre-Central Cluster regolith. It is also shown that chemical mixing models for bulk soil compositions can be misleading unless the petrologic characteristics of each soil are taken into account.

  10. Communicative Language Testing: Implications for Computer Based Language Testing in French for Specific Purposes

    ERIC Educational Resources Information Center

    García Laborda, Jesús; López Santiago, Mercedes; Otero de Juan, Nuria; Álvarez Álvarez, Alfredo

    2014-01-01

    Current evolutions of language testing have led to integrating computers in FSP assessments both in oral and written communicative tasks. This paper deals with two main issues: learners' expectations about the types of questions in FSP computer based assessments and the relation with their own experience. This paper describes the experience of 23…

  11. Hydrogen test of a small, low specific speed centrifugal pump stage

    NASA Technical Reports Server (NTRS)

    1991-01-01

    A small, low specific speed centrifugal pump stage with a 2 inch tip diameter, .030 inch tip width shrouded impeller and volute collector was tested with liquid hydrogen as the pumped fluid. The hydrodynamic design of the pump stage is summarized and the noncavitating and cavitating performance results are presented. Test speeds were 60 and 80 percent of the 77,000 rpm design speed. Liquid hydrogen test results are compared with data from previous tests of the stage in water.

  12. Inter-rater agreement, sensitivity, and specificity of the prone hip extension test and active straight leg raise test

    PubMed Central

    2014-01-01

    Background Two clinical tests used to assess for neuromuscular control deficits in low back pain (LBP) patients are the prone hip extension (PHE) test and active straight leg raise (ASLR) test. For these tests, it has been suggested examiners classify patients as “positive” or “negative” based on the presence or absence (respectively) of specific “abnormal” lumbopelvic motion patterns. The inter-rater agreement of such a classification scheme has been reported for the PHE test, but not for the ASLR test. In addition, the sensitivity and specificity of such classification schemes have not been reported for either test. The primary objectives of the current study were to investigate: 1) the inter-rater agreement of the examiner-reported classification schemes for these two tests, and 2) the sensitivity and specificity of the classification schemes. Methods Thirty participants with LBP and 40 asymptomatic controls took part in this cross-sectional observational study. Participants performed 3–4 repetitions of each test whilst two examiners classified them as “positive” or “negative” based on the presence or absence (respectively) of specific “abnormal” lumbopelvic motion patterns. The inter-rater agreement (Kappa statistic), sensitivity (LBP patients), and specificity (controls) were calculated for each test. Results Both tests demonstrated substantial inter-rater agreement (PHE test: Kappa = 0.76, 95% CI = 0.57-0.95, p < 0.001; ASLR test: Kappa = 0.76, 95% CI = 0.57-0.96, p < 0.001). For the PHE test, the sensitivity was 0.18-0.27 and the specificity was 0.63-0.78; the odds ratio (OR) of “positive” classifications in the LBP group was 1.25 (95% CI = 0.58-2.72; Examiner 1) and 1.27 (95% CI = 0.52-3.12; Examiner 2). For the ASLR test, the sensitivity was 0.20-0.25 and the specificity was 0.84-0.86; the OR of “positive” classifications in the LBP group was 1.72 (95% CI = 0.75-3.95; Examiner 1) and 1

  13. Siddhartha: Domain-specific unit test generation for "low-testibility" programs

    NASA Astrophysics Data System (ADS)

    Reyes, Arthur Alexander

    This Dissertation validates the hypothesis that domain-specific language (DSL) methodology can provide essential automation support for specification-based testing (SBT) of computer program units expressed in difficult-to-test (i.e., "low-testability"), domain-specific design styles. This Dissertation presents Siddhartha, an extension to DSL methodology for development of program synthesizers to support SBT methods in novel application domains. Synthesizers map formal test data specifications (TestSpecs) into unit test driver procedures (Drivers). Both TestSpecs and Driver reference designs are represented via DSLs. Synthesizer development is iterative and example-driven. A Domain Designer applying the Siddhartha methodology in a novel application domain first selects a collection of general, example TestSpecs, then manually codes a collection of corresponding Drivers. Each Driver is expressed in a different reference design that specifically accommodates difficult-to-test, domain-specific program unit under test (UUT) design styles. After selecting the most promising Driver reference design, the set of (TestSpec, Driver) pairs become test cases for the synthesizer under development. The Domain Designer then designs a TestSpec→Driver translation function. The translation function maps TestSpecs to Driver kernels in the selected reference design. The translation function design simplifies DSL development by modularizing both TestSpec and Driver reference design DSLs into syntactic productions. This effectively optimizes DSL representations to support efficient TestSpec→Driver synthesis. This Dissertation validates the hypothesis by answering the question "What are the relative costs and benefits of applying DSL methods to generate requirements-based and regression Drivers for a flight control system expressed in Ada?" Costs and benefits are measured with respect to manually coded Drivers, which are arguably equivalent to Drivers generated by a general

  14. Specificity of the comparative skin test for bovine tuberculosis in Great Britain

    PubMed Central

    Goodchild, A. V.; Downs, S. H.; Upton, P.; Wood, J. L. N.; de la Rua-Domenech, R.

    2015-01-01

    A novel method for estimating specificity of the Single Intradermal Comparative Cervical Tuberculin (SICCT) test for bovine tuberculosis (bTB) using surveillance tests results is reported. The specificity of the SICCT test at three cut-offs was estimated from the dates, locations and skinfold measurements of all routine tests carried out in Officially TB Free (OTF) cattle herds in Great Britain (GB) between 2002 and 2008, according to their separation (by distance and time) from known infected (OTF-withdrawn) herds. The proportion of animals that tested positive was constant (P>0.20) when the distance between tested herds and nearest infected herd exceeded 8 km. For standard cut-off, calculated specificity was 99.98 per cent (95 per cent confidence interval ±0.004 per cent), equating to one false positive result per 5000 uninfected animals tested. For severe cut-off it was 99.91 per cent (±0.013 per cent) and for ultrasevere cut-off (selecting all reactors and inconclusive reactors) it was 99.87 per cent (±0.017 per cent). The estimated positive predictive value of the test averaged 91 per cent and varied by regional prevalence. This study provides further evidence of the high specificity of the SICCT test under GB conditions, suggests that over 90 per cent of cattle currently culled using this test in GB were infected, and endorses slaughter of at least these cattle for bTB control. PMID:26338518

  15. Outbreak of Uncommon O4 Non-Agglutinating Salmonella Typhimurium Linked to Minced Pork, Saxony-Anhalt, Germany, January to April 2013

    PubMed Central

    Helmeke, Carina; Kohlstock, Claudia; Prager, Rita; Tietze, Erhard; Rabsch, Wolfgang; Karagiannis, Ioannis; Werber, Dirk; Frank, Christina; Fruth, Angelika

    2015-01-01

    Introduction In January 2013, the National Reference Centre for Salmonella (NRC) detected a salmonellosis cluster in Saxony-Anhalt, Germany, caused by uncommon O4 non-agglutinating, monophasic Salmonella (S.) Typhimurium DT193. Circulating predominant monophasic S. Typhimurium DT193 clones typically display resistance phenotype ASSuT. We investigated common exposures to control the outbreak, and conducted microbiological investigations to assess the strains’ phenotype. Methods We conducted a case-control study defining cases as persons living or working in Saxony-Anhalt diagnosed with the O4 non-agglutinating strain between January and March 2013. We selected two controls contemporarily reported with norovirus infection, frequency-matched on residence and age group, per case. We interviewed regarding food consumption, especially pork and its place of purchase. We calculated odds ratios (ORs) with 95% confidence intervals (95% CI) using logistic regression. The NRC investigated human and food isolates by PCR, SDS-PAGE, MLST, PFGE, MLVA and susceptibility testing. Results Altogether, 68 O4 non-agglutinating human isolates were confirmed between January and April 2013. Of those, 61 were assigned to the outbreak (median age 57 years, 44% female); 83% cases ≥ 60 years were hospitalized. Eating raw minced pork from butcheries within 3 days was associated with disease (31 cases, 28 controls; OR adjusted for sex: 3.6; 95% CI: 1.0-13). Phage type DT193 and MLST ST34 were assigned, and isolates’ lipopolysaccharide (LPS) matched control strains. Isolates linked to Saxony-Anhalt exhibited PFGE type 5. ASSuT- and ACSSuT phenotype proportions were 34 and 39% respectively; 54% were resistant to chloramphenicol. Three pork isolates matched the outbreak strain. Discussion Raw minced pork was the most likely infection vehicle in this first reported outbreak caused by O4 non-agglutinating, mostly chloramphenicol-resistant S. Typhimurium DT193. High hospitalization proportions

  16. Claims, Evidence and Achievement Level Descriptors as a Foundation for Item Design and Test Specifications

    ERIC Educational Resources Information Center

    Hendrickson, Amy; Huff, Kristen; Luecht, Ric

    2009-01-01

    [Slides] presented at the Annual Meeting of National Council on Measurement in Education (NCME) in San Diego, CA in April 2009. This presentation describes how the vehicles for gathering student evidence--task models and test specifications--are developed.

  17. A closure test for time-specific capture-recapture data

    USGS Publications Warehouse

    Stanley, T.R.; Burnham, K.P.

    1999-01-01

    The assumption of demographic closure in the analysis of capture-recapture data under closed-population models is of fundamental importance. Yet, little progress has been made in the development of omnibus tests of the closure assumption. We present a closure test for time-specific data that, in principle, tests the null hypothesis of closed-population model M(t) against the open-population Jolly-Seber model as a specific alternative. This test is chi-square, and can be decomposed into informative components that can be interpreted to determine the nature of closure violations. The test is most sensitive to permanent emigration and least sensitive to temporary emigration, and is of intermediate sensitivity to permanent or temporary immigration. This test is a versatile tool for testing the assumption of demographic closure in the analysis of capture-recapture data.

  18. Real time observation and automated measurement of red blood cells agglutination inside a passive microfluidic biochip containing embedded reagents.

    PubMed

    Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud

    2016-09-20

    The process of agglutination is commonly used for the detection of biomarkers like proteins or viruses. The multiple bindings between micrometer sized particles, either latex beads or red blood cells (RBCs), create aggregates that are easily detectable and give qualitative information about the presence of the biomarkers. In most cases, the detection is made by simple naked-eye observation of agglutinates without any access to the kinetics of agglutination. In this study, we address the development of a real-time time observation of RBCs agglutination. Using ABO blood typing as a proof-of-concept, we developed i) an integrated biological protocol suitable for further use as point-of-care (POC) analysis and ii) two dedicated image processing algorithms for the real-time and quantitative measurement of agglutination. Anti-A or anti-B typing reagents were dried inside the microchannel of a passive microfluidic chip designed to enhance capillary flow. A blood drop deposit at the tip of the biochip established a simple biological protocol. In situ agglutination of autologous RBCs was achieved by means of embedded reagents and real time agglutination process was monitored by video recording. Using a training set of 24 experiments, two real-time indicators based on correlation and variance of gray levels were optimized and then further confirmed on a validation set. 100% correct discrimination between positive and negative agglutinations was performed within less than 2min by measuring real-time evolution of both correlation and variance indicators.

  19. On the Use of a Test to Exhaustion Specific to Tennis (TEST) with Ball Hitting by Elite Players

    PubMed Central

    2016-01-01

    Purpose We aimed to a) introduce a new Test to Exhaustion Specific to Tennis (TEST) and compare performance (test duration) and physiological responses to those obtained during the 20-m multistage shuttle test (MSST), and b) determine to which extent those variables correlate with performance level (tennis competitive ranking) for both test procedures. Methods Twenty-seven junior players (8 males, 19 females) members of the national teams of the French Tennis Federation completed MSST and TEST, including elements of the game (ball hitting, intermittent activity, lateral displacement), in a randomized order. Cardiorespiratory responses were compared at submaximal (respiratory compensation point) and maximal loads between the two tests. Results At the respiratory compensation point oxygen uptake (50.1 ± 4.7 vs. 47.5 ± 4.3 mL.min-1.kg-1, p = 0.02), but not minute ventilation and heart rate, was higher for TEST compared to MSST. However, load increment and physiological responses at exhaustion did not differ between the two tests. Players’ ranking correlated negatively with oxygen uptake measured at submaximal and maximal loads for both TEST (r = -0.41; p = 0.01 and -0.55; p = 0.004) and MSST (r = -0.38; P = 0.05 and -0.51; p = 0.1). Conclusion Using TEST provides a tennis-specific assessment of aerobic fitness and may be used to prescribe aerobic exercise in a context more appropriate to the game than MSST. Results also indicate that VO2 values both at submaximal and maximal load reached during TEST and MSST are moderate predictors of players competitive ranking. PMID:27035342

  20. Cloning of a serotype-specific antigen from Pasteurella haemolytica A1.

    PubMed Central

    Gonzalez-Rayos, C; Lo, R Y; Shewen, P E; Beveridge, T J

    1986-01-01

    Recombinant plasmids coding for a soluble (or surface) antigen of Pasteurella haemolytica A1 were identified. Two plasmids, both containing the same 5.4 kilobase pairs of insert DNA, were recovered independently by screening a clone band of P. haemolytica A1 genomic DNA in Escherichia coli for the expression of P. haemolytica A1 soluble antigens (R. Y. C. Lo and L.A. Cameron, Can. J. Biochem. Cell Biol. 64:73-76, 1986). E. coli cells carrying the plasmids were found to be agglutinated by an antiserum raised against the P. haemolytica A1 soluble antigens. Analysis of the E. coli clones by electron microscopy revealed patches of amorphous material on the surface of the cells which were not present on the controls. Further characterization with protein A-colloidal gold labeled both these patches and the outer membranes of these cloned cells pretreated with the specific antiserum. These results indicated that the cloned antigen was expressed on the surface of the E. coli cells. The cloned antigen was found to be specific for serotype 1 when tested by slide agglutination against a collection of P. haemolytica typing antisera. Southern blot hybridization, using the cloned DNA as a probe, labeled the genomic DNA from P. haemolytica serotype 1 as well as the cross-agglutinating serotypes 2 and 7, but not DNA from the non-cross-agglutinating serotypes 3 and 4 and Pasteurella multocida. These results demonstrated that serotype specificity could be attributed to the particular antigenic determinants in the genome of the organism. Images PMID:3527985

  1. Estimating, Testing, and Comparing Specific Effects in Structural Equation Models: The Phantom Model Approach

    ERIC Educational Resources Information Center

    Macho, Siegfried; Ledermann, Thomas

    2011-01-01

    The phantom model approach for estimating, testing, and comparing specific effects within structural equation models (SEMs) is presented. The rationale underlying this novel method consists in representing the specific effect to be assessed as a total effect within a separate latent variable model, the phantom model that is added to the main…

  2. Low specificities of HIV diagnostic tests caused by Trypanosoma brucei gambiense sleeping sickness.

    PubMed

    Lejon, V; Ngoyi, D Mumba; Ilunga, M; Beelaert, G; Maes, I; Büscher, P; Fransen, K

    2010-08-01

    The accuracy of diagnostic tests for HIV in patients with tropical infections is poorly documented. Human African trypanosomiasis (HAT) is characterized by a polyclonal B-cell activation, constituting a risk for false-positive reactions to diagnostic tests, including HIV tests. A retrospective study of the accuracy of HIV diagnostic tests was performed with 360 human African HAT patients infected with Trypanosoma brucei gambiense before treatment and 163 T. b. gambiense-infected patients 2 years after successful treatment in Mbuji Mayi, East Kasai, Democratic Republic of the Congo. The sensitivities, specificities, and positive predictive values (PPVs) of individual tests and algorithms consisting of 3 rapid tests were determined. The sensitivity of all tests was 100% (11/11). The low specificity (96.3%, 335/348) and PPV (45.8%, 11/24) of a classical seroconfirmation strategy (Vironostika enzyme-linked immunosorbent assay [ELISA] followed by line immunoassay) complicated the determination of HIV status, which had to be determined by PCR. The specificities of the rapid diagnostic tests were 39.1% for Determine (136/348); 85.3 to 92.8% (297/348 to 323/348) for Vikia, ImmunoFlow, DoubleCheck, and Bioline; and 96.6 to 98.3% (336/348 to 342/348) for Uni-Gold, OraQuick, and Stat-Pak. The specificity of Vironostika was 67.5% (235/348). PPVs ranged between 4.9 and 64.7%. Combining 3 different rapid tests resulted in specificities of 98.3 to 100% (342/348 to 348/348) and PPVs of 64.7 to 100% (11/17 to 11/11). For cured HAT patients, specificities were significantly higher for Vironostika, Determine, Uni-Gold, and ImmunoFlow. T. b. gambiense infection decreases the specificities of antibody detection tests for HIV diagnosis. Unless tests have been validated for interference with HAT, HIV diagnosis using classical algorithms in untreated HAT patients should be avoided. Specific, validated combinations of 3 HIV rapid tests can increase specificity.

  3. Single agglutinates: A comparative study of compositions of agglutinitic glass, whole-grain, bulk soil, and FMR

    NASA Technical Reports Server (NTRS)

    Basu, A.; Robinson, R.; Mckay, D. S.; Blanchard, D. P.; Morris, R. V.; Wentworth, Susan J.

    1994-01-01

    Previous workers on single agglutinates have variously interpreted the composition of agglutinitic glass to represent impact melts of (1) bulk soil, (2) mixed components in finer sizes, and (3) microtargets. Separately, Papike has argued in favor of fusion of the finest fraction of bulk soils. Thirty-four single agglutinates were hand-picked from the mature Apollo 16 soil 61181 (I(sub s)/FeO = 82) and the FMR and chemical composition (INAA for Fe, Sc, Sm, Co, Ni, and Cr) of each agglutinate particle were measured. Thirteen of these single agglutinates were selected for electron beam microanalysis and imaging. Less than 1 micron spots were analyzed (for Na, Mg, Al, Si, P, S, K, Ca, Ti, Cr, Mn, Fe, Ni, and Ba) on pure glassy areas (approximately ten in each particle) selected on the basis of optical and BSE images (avoiding all clasts and inclusions) with an electron microprobe to obtain average glass compositions of each single agglutinate.

  4. Vertical jumping tests in volleyball: reliability, validity, and playing-position specifics.

    PubMed

    Sattler, Tine; Sekulic, Damir; Hadzic, Vedran; Uljevic, Ognjen; Dervisevic, Edvin

    2012-06-01

    Vertical jumping is known to be important in volleyball, and jumping performance tests are frequently studied for their reliability and validity. However, most studies concerning jumping in volleyball have dealt with standard rather than sport-specific jumping procedures and tests. The aims of this study, therefore, were (a) to determine the reliability and factorial validity of 2 volleyball-specific jumping tests, the block jump (BJ) test and the attack jump (AJ) test, relative to 2 frequently used and systematically validated jumping tests, the countermovement jump test and the squat jump test and (b) to establish volleyball position-specific differences in the jumping tests and simple anthropometric indices (body height [BH], body weight, and body mass index [BMI]). The BJ was performed from a defensive volleyball position, with the hands positioned in front of the chest. During an AJ, the players used a 2- to 3-step approach and performed a drop jump with an arm swing followed by a quick vertical jump. A total of 95 high-level volleyball players (all men) participated in this study. The reliability of the jumping tests ranged from 0.97 to 0.99 for Cronbach's alpha coefficients, from 0.93 to 0.97 for interitem correlation coefficients and from 2.1 to 2.8 for coefficients of variation. The highest reliability was found for the specific jumping tests. The factor analysis extracted one significant component, and all of the tests were highly intercorrelated. The analysis of variance with post hoc analysis showed significant differences between 5 playing positions in some of the jumping tests. In general, receivers had a greater jumping capacity, followed by libero players. The differences in jumping capacities should be emphasized vis-a-vis differences in the anthropometric measures of players, where middle hitters had higher BH and body weight, followed by opposite hitters and receivers, with no differences in the BMI between positions.

  5. Development of electrical test procedures for qualification of spacecraft against EID. Volume 2: Review and specification of test procedures

    NASA Technical Reports Server (NTRS)

    Wilkenfeld, J. M.; Harlacher, B. L.; Mathews, D.

    1982-01-01

    A combined experimental and analytical program to develop system electrical test procedures for the qualification of spacecraft against damage produced by space-electron-induced discharges (EID) occurring on spacecraft dielectric outer surfaces is described. A review and critical evaluation of possible approaches to qualify spacecraft against space electron-induced discharges (EID) is presented. A variety of possible schemes to simulate EID electromagnetic effects produced in spacecraft was studied. These techniques form the principal element of a provisional, recommended set of test procedures for the EID qualification spacecraft. Significant gaps in our knowledge about EID which impact the final specification of an electrical test to qualify spacecraft against EID are also identified.

  6. Testing Job-Specific Literacy of Industrial Workers: Cooperation between Educators and Industry.

    ERIC Educational Resources Information Center

    Anderson, William W.; Stewart, Oran J.

    A test of job-specific literacy, called the McCoy Assessment of Worksite Literacy Abilities (MAWSLA), could not predict the job success of the 100 employees who took it. The 108-item test was based on literary tasks encountered by employees in the course of a routine day at McCoy Electronics Company, a 560-employee firm in Pennsylvania. The…

  7. Specific Resistance. Operational Control Tests for Wastewater Facilities. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Wooley, John F.

    A commonly used test for determining filterability of conditioned sludge is the specific resistance (Buchner funnel) test. The sludge is filtered through filter paper using a Buchner funnel, and the time needed to obtain a given volume of filtrate (or for cake residue to begin to crack) is measured. The shorter the time, the better the…

  8. Proceedings: Nozzle Initiative Industry Advisory Committee on Standardization of Carbon-Phenolic Test Methods and Specifications

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The proceedings of the meeting is presented in conversational form. Some areas of discussion are as follow: resin advancement at NASA Marshall new technologies studies; NMR studies; SPIP/PAN development summary; computer modeling support; composite testing; carbon assay testing; activity and aerospace computer database; alternate rayon yarn sizing; fiber morphology; and carbon microballoons specifications.

  9. Investigations into the Appropriate Use of Various Item Types for Testing Specific Levels of Reading Proficiency.

    ERIC Educational Resources Information Center

    McIntyre, Sandra

    A study investigated the appropriate use of item types for testing reading at various levels of proficiency. It was specifically concerned with item types found in the standardized group-administered Defense Language Proficiency Tests. The item formats investigated were signs in the target language, identification of underlined information,…

  10. Development of a Culture Specific Critical Thinking Ability Test and Using It as a Supportive Diagnostic Test for Giftedness

    ERIC Educational Resources Information Center

    Köksal, Mustafa Serdar

    2016-01-01

    The purposes of this study were to develop a culture specific critical thinking ability test for 6, 7, and 8. grade students in Turkey and to use it as an assessment instrument for giftedness. For these purposes, item pool involving 22 items was formed by writing items focusing on the current and common events presented in (Turkish) media from…

  11. Domain-General and Domain-Specific Creative-Thinking Tests: Effects of Gender and Item Content on Test Performance

    ERIC Educational Resources Information Center

    Hong, Eunsook; Peng, Yun; O'Neil, Harold F., Jr.; Wu, Junbin

    2013-01-01

    The study examined the effects of gender and item content of domain-general and domain-specific creative-thinking tests on four subscale scores of creative-thinking (fluency, flexibility, originality, and elaboration). Chinese tenth-grade students (234 males and 244 females) participated in the study. Domain-general creative thinking was measured…

  12. Reading Development in Agglutinative Languages: Evidence from Beginning, Intermediate, and Adult Basque Readers

    ERIC Educational Resources Information Center

    Acha, Joana; Laka, Itziar; Perea, Manuel

    2010-01-01

    Do typological properties of language, such as agglutination (i.e., the morphological process of adding affixes to the lexeme of a word), have an impact on the development of visual word recognition? To answer this question, we carried out an experiment in which beginning, intermediate, and adult Basque readers (n = 32 each, average age = 7, 11,…

  13. 26. "TEST STAND, STRUCTURAL, FOUNDATION PLAN." Specifications No. ENG043535572; Drawing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. "TEST STAND, STRUCTURAL, FOUNDATION PLAN." Specifications No. ENG-04-353-55-72; Drawing No. 60-0912; sheet 25 of 148; file no. 1320/76. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  14. Proceedings of the Advisory Committee on standardization of carbon-phenolic test methods and specifications

    NASA Technical Reports Server (NTRS)

    Hall, William B.

    1991-01-01

    Proceedings of the Advisory Committee on Standardization of carbon-phenolic test methods and specifications are compiled. The following subject areas are covered: ashing procedures and alkali metal content of carbon fiber and fabrics; SPIP product identification code; SPIP initiative to adopt a water-soluble rayon yarn lubricant/size for weaving; fabric oxidation mass loss test; shelf life limit for prepregs, industry standard; silicon contamination update; resin, filler, and fabric content in prepreg; carbon assay testing calibration; thiokol rayon specifications; and SPIP low conductivity PAN program.

  15. Gene set analysis for self-contained tests: complex null and specific alternative hypotheses

    PubMed Central

    Rahmatallah, Y.; Glazko, G.

    2012-01-01

    Motivation: The analysis of differentially expressed gene sets became a routine in the analyses of gene expression data. There is a multitude of tests available, ranging from aggregation tests that summarize gene-level statistics for a gene set to true multivariate tests, accounting for intergene correlations. Most of them detect complex departures from the null hypothesis but when the null hypothesis is rejected, the specific alternative leading to the rejection is not easily identifiable. Results: In this article we compare the power and Type I error rates of minimum-spanning tree (MST)-based non-parametric multivariate tests with several multivariate and aggregation tests, which are frequently used for pathway analyses. In our simulation study, we demonstrate that MST-based tests have power that is for many settings comparable with the power of conventional approaches, but outperform them in specific regions of the parameter space corresponding to biologically relevant configurations. Further, we find for simulated and for gene expression data that MST-based tests discriminate well against shift and scale alternatives. As a general result, we suggest a two-step practical analysis strategy that may increase the interpretability of experimental data: first, apply the most powerful multivariate test to find the subset of pathways for which the null hypothesis is rejected and second, apply MST-based tests to these pathways to select those that support specific alternative hypotheses. Contact: gvglazko@uams.edu or yrahmatallah@uams.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:23044539

  16. Nozzle Initiative Industry Advisory Committee on Standardization of Carbon-Phenolic Test Methods and Specifications

    NASA Technical Reports Server (NTRS)

    Bull, William B. (Compiler); Pinoli, Pat C. (Compiler); Upton, Cindy G. (Compiler); Day, Tony (Compiler); Hill, Keith (Compiler); Stone, Frank (Compiler); Hall, William B.

    1994-01-01

    This report is a compendium of the presentations of the 12th biannual meeting of the Industry Advisory Committee under the Solid Propulsion Integrity Program. A complete transcript of the welcoming talks is provided. Presentation outlines and overheads are included for the other sessions: SPIP Overview, Past, Current and Future Activity; Test Methods Manual and Video Tape Library; Air Force Developed Computer Aided Cure Program and SPC/TQM Experience; Magneto-Optical mapper (MOM), Joint Army/NASA program to assess composite integrity; Permeability Testing; Moisture Effusion Testing by Karl Fischer Analysis; Statistical Analysis of Acceptance Test Data; NMR Phenolic Resin Advancement; Constituent Testing Highlights on the LDC Optimization Program; Carbon Sulfur Study, Performance Related Testing; Current Rayon Specifications and Future Availability; RSRM/SPC Implementation; SRM Test Methods, Delta/Titan/FBM/RSRM; and Open Forum on Performance Based Acceptance Testing -- Industry Experience.

  17. DEVELOPMENT OF BURN TEST SPECIFICATIONS FOR FIRE PROTECTION MATERIALS IN RAM PACKAGES

    SciTech Connect

    Gupta, N.

    2010-03-03

    The regulations in 10 CFR 71 require that the radioactive material (RAM) packages must be able to withstand specific fire conditions given in 10 CFR 71.73 during Hypothetical Accident Conditions (HAC). This requirement is normally satisfied by extensive testing of full scale test specimens under required test conditions. Since fire test planning and execution is expensive and only provides a single snapshot into a package performance, every effort is made to minimize testing and supplement tests with results from computational thermal models. However, the accuracy of such thermal models depends heavily on the thermal properties of the fire insulating materials that are rarely available at the regulatory fire temperatures. To the best of authors knowledge no test standards exist that could be used to test the insulating materials and derive their thermal properties for the RAM package design. This paper presents a review of the existing industry fire testing standards and proposes testing methods that could serve as a standardized specification for testing fire insulating materials for use in RAM packages.

  18. The Production of Nominal and Verbal Inflection in an Agglutinative Language: Evidence from Hungarian

    PubMed Central

    Peckham, Don; Szanka, Szilvia; Gazso, Dorottya; Lovassy, Noemi; Ullman, Michael T.

    2015-01-01

    The contrast between regular and irregular inflectional morphology has been useful in investigating the functional and neural architecture of language. However, most studies have examined the regular/irregular distinction in non-agglutinative Indo-European languages (primarily English) with relatively simple morphology. Additionally, the majority of research has focused on verbal rather than nominal inflectional morphology. The present study attempts to address these gaps by introducing both plural and past tense production tasks in Hungarian, an agglutinative non-Indo-European language with complex morphology. Here we report results on these tasks from healthy Hungarian native-speaking adults, in whom we examine regular and irregular nominal and verbal inflection in a within-subjects design. Regular and irregular nouns and verbs were stem on frequency, word length, and phonological structure, and both accuracy and response times were acquired. The results revealed that the regular/irregular contrast yields similar patterns in Hungarian, for both nominal and verbal inflection, as in previous studies of non-agglutinative Indo-European languages: the production of irregular inflected forms was both less accurate and slower than of regular forms, both for plural and past-tense inflection. The results replicate and extend previous findings to an agglutinative language with complex morphology. Together with previous studies, the evidence suggests that the regular/irregular distinction yields a basic behavioral pattern that holds across language families and linguistic typologies. Finally, the study sets the stage for further research examining the neurocognitive substrates of regular and irregular morphology in an agglutinative non-Indo-European language. PMID:25769039

  19. Interactions with lectins and agglutination profiles of clinical, food, and environmental isolates of Listeria.

    PubMed Central

    Facinelli, B; Giovanetti, E; Casolari, C; Varaldo, P E

    1994-01-01

    On the basis of preliminary trials with 14 collection strains of Listeria, five lectins (Canavalia ensiformis, concanavalin A; Griffonia simplicifolia lectin I; Helix pomatia agglutinin; Ricinus communis agglutinin; and Triticum vulgaris wheat germ agglutinin) were selected to set up a microtiter agglutination assay. The lectin agglutination profiles of 174 clinical, food, and environmental strains of Listeria monocytogenes, Listeria innocua, and Listeria seeligeri were investigated. Data on the standard determination of the antigenic structure were available for clinical strains; nonclinical isolates were assigned to serogroup 1 or 4 with commercial antisera. The listeria-lectin interaction was related to serological type rather than species; in particular, the strains assigned to serogroup 1 or belonging to serovars 1/2a, 1/2b, 1/2c, 3a, 3b, and 7 were never agglutinated by G. simplicifolia lectin I. The five-lectin set proved to be capable of detecting differences between serologically identical isolates of L. monocytogenes. Of the 150 isolates of this species, 144 were distributed over 15 different lectin agglutination profiles and 6 autoagglutinated, the overall typeability being 96%. However, the profiles encountered among L. monocytogenes isolates were not randomly distributed. With strains assigned to serogroup 1 or belonging to serovars 1/2a, 1/2b, 1/2c, and 3b, the clinical isolates fell into only two of the eight patterns recorded overall; with strains of serogroup 4 and serovar 4b, food and environmental isolates were distributed over eight of the nine patterns found in total, while clinical isolates were distributed over five patterns. In a comparative study of 15 epidemiologically relevant isolates of L. monocytogenes from five distinct outbreaks, strains with identical phage types and/or DNA fingerprints displayed identical lectin profiles. The heterogeneity of agglutination profiles may form the basis of a new approach to L. monocytogenes typing

  20. The production of nominal and verbal inflection in an agglutinative language: evidence from Hungarian.

    PubMed

    Nemeth, Dezso; Janacsek, Karolina; Turi, Zsolt; Lukacs, Agnes; Peckham, Don; Szanka, Szilvia; Gazso, Dorottya; Lovassy, Noemi; Ullman, Michael T

    2015-01-01

    The contrast between regular and irregular inflectional morphology has been useful in investigating the functional and neural architecture of language. However, most studies have examined the regular/irregular distinction in non-agglutinative Indo-European languages (primarily English) with relatively simple morphology. Additionally, the majority of research has focused on verbal rather than nominal inflectional morphology. The present study attempts to address these gaps by introducing both plural and past tense production tasks in Hungarian, an agglutinative non-Indo-European language with complex morphology. Here we report results on these tasks from healthy Hungarian native-speaking adults, in whom we examine regular and irregular nominal and verbal inflection in a within-subjects design. Regular and irregular nouns and verbs were stem on frequency, word length, and phonological structure, and both accuracy and response times were acquired. The results revealed that the regular/irregular contrast yields similar patterns in Hungarian, for both nominal and verbal inflection, as in previous studies of non-agglutinative Indo-European languages: the production of irregular inflected forms was both less accurate and slower than of regular forms, both for plural and past-tense inflection. The results replicate and extend previous findings to an agglutinative language with complex morphology. Together with previous studies, the evidence suggests that the regular/irregular distinction yields a basic behavioral pattern that holds across language families and linguistic typologies. Finally, the study sets the stage for further research examining the neurocognitive substrates of regular and irregular morphology in an agglutinative non-Indo-European language.

  1. Treponema pallidum specific IgM haemagglutination test for serodiagnosis of syphilis.

    PubMed Central

    Sato, T; Kubo, E; Yokota, M; Kayashima, T; Tomizawa, T

    1984-01-01

    The Treponema pallidum specific IgM haemagglutination (TP-IgM-HA) test uses erythrocytes sensitised with antiserum to human IgM to separate IgM from IgG in serum. Specific antitreponemal IgM captured in this way is detected by adding a second reagent comprising erythrocytes sensitised with T pallidum antigen. Eighty two serum samples from 82 patients with untreated syphilis, 521 samples from 73 patients with treated syphilis, and 1872 samples from people who did not have syphilis were examined by the 19S(IgM)-TPHA (T pallidum haemagglutination), IgM-FTA-ABS (fluorescent treponemal antibody absorbed), TP-IgM-ELISA (enzyme linked immunosorbent assay), and TP-IgM-HA tests for the presence of 19S(IgM) antibodies specific to treponemes. The sensitivity of the TP-IgM-HA test was 97.6% and the specificity was 99.7%. We also traced IgM specific to treponemes in untreated patients with primary syphilis by four different tests. The TP-IgM-HA test results clearly reflected the effect of the treatment. PMID:6394097

  2. Prostate-specific antigen testing in inner London general practices: are those at higher risk most likely to get tested?

    PubMed Central

    Nderitu, Paul; Van Hemelrijck, Mieke; Ashworth, Mark; Mathur, Rohini; Hull, Sally; Dudek, Alexandra; Chowdhury, Simon

    2016-01-01

    Objectives To investigate the association between factors influencing prostate-specific antigen (PSA) testing prevalence including prostate cancer risk factors (age, ethnicity, obesity) and non-risk factors (social deprivation and comorbidity). Setting A cross-sectional database of 136 inner London general practices from 1 August 2009 to 31 July 2014. Participants Men aged ≥40 years without prostate cancer were included (n=150 481). Primary outcome Logistic regression analyses were used to estimate the association between PSA testing and age, ethnicity, social deprivation, body mass index (BMI) and comorbidity while adjusting for age, benign prostatic hypertrophy, prostatitis and tamsulosin or finasteride use. Results PSA testing prevalence was 8.2% (2013–2014), and the mean age was 54 years (SD 11). PSA testing was positively associated with age (OR 70–74 years compared to 40–44 years: 7.34 (95% CI 6.82 to 7.90)), ethnicity (black) (OR compared to white: 1.78 (95% CI 1.71 to 1.85)), increasing BMI and cardiovascular comorbidity. Testing was negatively associated with Chinese ethnicity and with increasing social deprivation. Conclusions PSA testing among black patients was higher compared to that among white patients, which differs from lower testing rates seen in previous studies. PSA testing was positively associated with prostate cancer risk factors and non-risk factors. Association with non-risk factors may increase the risk of unnecessary invasive diagnostic procedures. PMID:27406644

  3. Estimating, testing, and comparing specific effects in structural equation models: the phantom model approach.

    PubMed

    Macho, Siegfried; Ledermann, Thomas

    2011-03-01

    The phantom model approach for estimating, testing, and comparing specific effects within structural equation models (SEMs) is presented. The rationale underlying this novel method consists in representing the specific effect to be assessed as a total effect within a separate latent variable model, the phantom model that is added to the main model. The following favorable features characterize the method: (a) It enables the estimation, testing, and comparison of arbitrary specific effects for recursive and nonrecursive models with latent and manifest variables; (b) it enables the bootstrapping of confidence intervals; and (c) it can be applied with all standard SEM programs permitting latent variables, the specification of equality constraints, and the bootstrapping of total effects. These features along with the fact that no manipulation of matrices and formulas is required make the approach particularly suitable for applied researchers. The method is illustrated by means of 3 examples with real data sets.

  4. Effects of Tributyltin Antifouling Paint Leachates on Pearl Harbor Organisms. Site-Specific Flowthrough Bioassay Tests.

    DTIC Science & Technology

    1985-12-01

    Organotin paint leachate. antifoulitip coa~tings. marine n~ii r, isms.A.benthicFIEL GRUP SB GOUP organisms. harbor pollutani fributt Iti omplx cmmuitie...of organotins should be closely monitored for ossible shifts in dominance of specific organisms- ~ 20 DISTRIBUJTION, AVAILABIUITY OF ABSTRACT 21...d* J 77. EXECUTIVE SUMMARY Site-specific bioassay tests were performed to determine the effects of organotin paint leachate on complex communities of

  5. Development of a sports specific aerobic capacity test for karate - a pilot study.

    PubMed

    Nunan, David

    2006-01-01

    The purpose of the study was to develop an aerobic fitness assessment test for competitive Karate practitioners and describe the preliminary findings. Five well-trained, competitive Karate practitioners participated in this study. A protocol simulating common attack strikes used in competition Karate sparring was developed from video analysis. In addition, pilot testing established a specific sequence of strikes and timings to be used in the test. The time to perform the strike sequence remained the same, whilst the time between strike sequence performances was progressively reduced. The aim of the test was to increase intensity of exercise through a decrease in recovery. On two separate occasions, absolute and relative peak oxygen uptake (VO2peak), peak ventilation (VEpeak), maximum heart rate (HRM), and time to exhaustion (TE) obtained during the test were recorded. Subjective feedback provided by the participants was positive in that participants felt the test accurately simulated actions of a competitive sparring situation, and as a result athletes felt more motivated to perform well on this test. There was no significant between test difference in absolute VO2peak, relative VO2peak, HRM and TE (p > 0.05), indicating a potentially high reproducibility with the new test for these variables (test 1-test 2 difference of 0.04 L·min(-1), 1 ml·kg(-1)·min(-1), -3 beats·min(-1), and 28 s; respectively). However, VEpeak displayed potentially less reproducibility due to a significant difference observed between tests (test 1- test 2 difference of -2.8 L·min(-1), p < 0.05). There was a significant relationship between TE and relative VO2peak (R(2) = 0.77, p < 0.001). Further developments to the test will need to address issues with work rate/force output assessment/monitoring. The new test accurately simulates the actions of competitive Karate sparring. Key PointsThis is the first attempt at an aerobic fitness test specific to competitive Karate practitioners

  6. Development of a Sports Specific Aerobic Capacity Test for Karate - A Pilot Study

    PubMed Central

    Nunan, David

    2006-01-01

    The purpose of the study was to develop an aerobic fitness assessment test for competitive Karate practitioners and describe the preliminary findings. Five well-trained, competitive Karate practitioners participated in this study. A protocol simulating common attack strikes used in competition Karate sparring was developed from video analysis. In addition, pilot testing established a specific sequence of strikes and timings to be used in the test. The time to perform the strike sequence remained the same, whilst the time between strike sequence performances was progressively reduced. The aim of the test was to increase intensity of exercise through a decrease in recovery. On two separate occasions, absolute and relative peak oxygen uptake (VO2peak), peak ventilation (VEpeak), maximum heart rate (HRM), and time to exhaustion (TE) obtained during the test were recorded. Subjective feedback provided by the participants was positive in that participants felt the test accurately simulated actions of a competitive sparring situation, and as a result athletes felt more motivated to perform well on this test. There was no significant between test difference in absolute VO2peak, relative VO2peak, HRM and TE (p > 0.05), indicating a potentially high reproducibility with the new test for these variables (test 1-test 2 difference of 0.04 L·min-1, 1 ml·kg-1·min-1, -3 beats·min-1, and 28 s; respectively). However, VEpeak displayed potentially less reproducibility due to a significant difference observed between tests (test 1- test 2 difference of -2.8 L·min-1, p < 0.05). There was a significant relationship between TE and relative VO2peak (R2 = 0.77, p < 0.001). Further developments to the test will need to address issues with work rate/force output assessment/monitoring. The new test accurately simulates the actions of competitive Karate sparring. Key Points This is the first attempt at an aerobic fitness test specific to competitive Karate practitioners Anecdotal reports

  7. Sensitivity and specificity of parallel or serial serological testing for detection of canine Leishmania infection.

    PubMed

    Arruda, Mauro Maciel de; Figueiredo, Fabiano Borges; Marcelino, Andreza Pain; Barbosa, José Ronaldo; Werneck, Guilherme Loureiro; Noronha, Elza Ferreira; Romero, Gustavo Adolfo Sierra

    2016-03-01

    In Brazil, human and canine visceral leishmaniasis (CVL) caused by Leishmania infantum has undergone urbanisation since 1980, constituting a public health problem, and serological tests are tools of choice for identifying infected dogs. Until recently, the Brazilian zoonoses control program recommended enzyme-linked immunosorbent assays (ELISA) and indirect immunofluorescence assays (IFA) as the screening and confirmatory methods, respectively, for the detection of canine infection. The purpose of this study was to estimate the accuracy of ELISA and IFA in parallel or serial combinations. The reference standard comprised the results of direct visualisation of parasites in histological sections, immunohistochemical test, or isolation of the parasite in culture. Samples from 98 cases and 1,327 noncases were included. Individually, both tests presented sensitivity of 91.8% and 90.8%, and specificity of 83.4 and 53.4%, for the ELISA and IFA, respectively. When tests were used in parallel combination, sensitivity attained 99.2%, while specificity dropped to 44.8%. When used in serial combination (ELISA followed by IFA), decreased sensitivity (83.3%) and increased specificity (92.5%) were observed. Serial testing approach improved specificity with moderate loss in sensitivity. This strategy could partially fulfill the needs of public health and dog owners for a more accurate diagnosis of CVL.

  8. Specific PCR detection of tiger, leopard, and lion ingredients from test samples.

    PubMed

    Cao, Jijuan; Xu, Junyi; Liu, Ran; Yu, Ke; Wang, Changwen

    2011-01-01

    A PCR method was developed for specific detection of tiger, leopard, and lion DNA from test specimens for inspection and quarantine or for law-enforced animal protection. Three pairs of specific primers were designed based on the mitochondrial cytochrome b gene of tiger, leopard, and lion and used in the PCR testing. To mimic the effect of food processing on the sensitivity of the test, the tiger muscle and bovine bonemeal powder samples were treated at 133 degrees C for 30 min. At this processing condition, the method was sensitive enough to detect as low as 0.05% of tiger-derived ingredients from the mixed bonemeal powders. The data demonstrate that our PCR method is convenient and economic, with high sensitivity and repeatability, and can be used to detect and identify tiger, leopard, and lion ingredients from various test samples.

  9. METHOD AND APPARATUS FOR TESTING THE PRESENCE OF SPECIFIC ATOMIC ELEMENTS IN A SUBSTANCE

    DOEpatents

    Putman, J.L.

    1960-01-26

    Detection of specific atomic elements in a substance and particularly the applicability to well logging are discussed. The principal novelty resides in the determination of several of the auxiliary energy peaks in addition to the main energy peak of the gamma-ray energy spectrum of a substance and comparison of such peaks to the spectrum of the specific atomic element being tested for. thus resulting in identification of same. The invention facilitates the identification of specific elements even when in the presence of other elements having similar gamma energy spectra as to the main energy peaks.

  10. Immediate hypersensitivity to penicillins with negative skin tests--the value of specific IgE.

    PubMed

    Silva, R; Cruz, L; Botelho, C; Castro, E; Cadinha, S; Castel-Branco, M G; Rodrigues, J

    2009-08-01

    The determination of specific IgE in patients with history of penicillins hypersensitivity is simple, safe and widely available. The positive and negative predictive values of this determination, however, are not yet established. In order to evaluate them, we performed specific IgE determination and diagnostic drug challenges in a group of 22 patients with a clear history of immediate penicillins hypersensitivity but negative skin tests. In this sample, the positive and negative predictive values were 29% and 87%, respectively. This seems to indicate that a positive specific IgE is not enough to confirm the diagnosis, and further study is necessary.

  11. Determination of specific yield for the Biscayne Aquifer with a canal-drawdown test.

    PubMed

    Bolster, C H; Genereux, D P; Saiers, J E

    2001-01-01

    Data from a large-scale canal-drawdown test were used to estimate the specific yield (sy) of the Biscayne Aquifer, an unconfined limestone aquifer in southeast Florida. The drawdown test involved dropping the water level in a canal by about 30 cm and monitoring the response of hydraulic head in the surrounding aquifer. Specific yield was determined by analyzing data from the unsteady portion of the drawdown test using an analytical stream-aquifer interaction model (Zlotnik and Huang 1999). Specific yield values computed from drawdown at individual piezometers ranged from 0.050 to 0.57, most likely indicating heterogeneity of specific yield within the aquifer (small-scale variation in hydraulic conductivity may also have contributed to the differences in sy among piezometers). A value of 0.15 (our best estimate) was computed based on all drawdown data from all piezometers. We incorporated our best estimate of specific yield into a large-scale two-dimensional numerical MODFLOW-based ground water flow model and made predictions of head during a 183-day period at four wells located 337 to 2546 m from the canal. We found good agreement between observed and predicted heads, indicating our estimate of specific yield is representative of the large portion of the Biscayne Aquifer studied here. This work represents a practical and novel approach to the determination of a key hydrogeological parameter (the storage parameter needed for simulation and calculation of transient unconfined ground water flow), at a large spatial scale (a common scale for water resource modeling), for a highly transmissive limestone aquifer (in which execution of a traditional pump test would be impractical and would likely yield ambiguous results). Accurate estimates of specific yield and other hydrogeological parameters are critical for management of water supply, Everglades environmental restoration, flood control, and other issues related to the ground water hydrology of the Biscayne Aquifer.

  12. Sport-Specific Motor Fitness Tests in Water Polo: Reliability, Validity and Playing Position Differences

    PubMed Central

    Uljevic, Ognjen; Spasic, Miodrag; Sekulic, Damir

    2013-01-01

    Sport-specific motor fitness tests are not often examined in water polo. In this study we examined the reliability, factorial and discriminative validity of 10 water-polo-specific motor-fitness tests, namely: three tests of in-water jumps (thrusts), two characteristic swimming sprints (10 and 20 metres from the water start), three ball-throws (shoots), one test of passing precision (accuracy), and a test of the dynamometric force produced while using the eggbeater kick. The sample of subjects consisted of 54 young male water polo players (15 to 17 years of age; 1.86 ± 0.07 m, and 83.1 ± 9.9 kg). All tests were applied over three testing trials. Reliability analyses included Cronbach Alpha coefficients (CA), inter-item- correlations (IIR) and coefficients of the variation (CV), while an analysis of variance was used to define any systematic bias between the testing trials. All tests except the test of accuracy (precision) were found to be reliable (CA ranged from 0.83 to 0.97; IIR from 0.62 to 0.91; CV from 2% to 21%); with small and irregular biases between the testing trials. Factor analysis revealed that jumping capacities as well as throwing and sprinting capacities should be observed as a relatively independent latent dimensions among young water polo players. Discriminative validity of the applied tests is partially proven since the playing positions significantly (p < 0.05) differed in some of the applied tests, with the points being superior in their fitness capacities in comparison to their teammates. This study included players from one of the world’s best junior National leagues, and reported values could be used as fitness standards for such an age. Further studies are needed to examine the applicability of the proposed test procedures to older subjects and females. Key Points Here presented and validated sport specific water polo motor fitness tests are found to be reliable in the sample of young male water polo players. Factor analysis revealed

  13. Sport-specific motor fitness tests in water polo: reliability, validity and playing position differences.

    PubMed

    Uljevic, Ognjen; Spasic, Miodrag; Sekulic, Damir

    2013-01-01

    Sport-specific motor fitness tests are not often examined in water polo. In this study we examined the reliability, factorial and discriminative validity of 10 water-polo-specific motor-fitness tests, namely: three tests of in-water jumps (thrusts), two characteristic swimming sprints (10 and 20 metres from the water start), three ball-throws (shoots), one test of passing precision (accuracy), and a test of the dynamometric force produced while using the eggbeater kick. The sample of subjects consisted of 54 young male water polo players (15 to 17 years of age; 1.86 ± 0.07 m, and 83.1 ± 9.9 kg). All tests were applied over three testing trials. Reliability analyses included Cronbach Alpha coefficients (CA), inter-item- correlations (IIR) and coefficients of the variation (CV), while an analysis of variance was used to define any systematic bias between the testing trials. All tests except the test of accuracy (precision) were found to be reliable (CA ranged from 0.83 to 0.97; IIR from 0.62 to 0.91; CV from 2% to 21%); with small and irregular biases between the testing trials. Factor analysis revealed that jumping capacities as well as throwing and sprinting capacities should be observed as a relatively independent latent dimensions among young water polo players. Discriminative validity of the applied tests is partially proven since the playing positions significantly (p < 0.05) differed in some of the applied tests, with the points being superior in their fitness capacities in comparison to their teammates. This study included players from one of the world's best junior National leagues, and reported values could be used as fitness standards for such an age. Further studies are needed to examine the applicability of the proposed test procedures to older subjects and females. Key PointsHere presented and validated sport specific water polo motor fitness tests are found to be reliable in the sample of young male water polo players.Factor analysis revealed

  14. Effects of a carbohydrate-electrolyte drink on specific soccer tests and performance.

    PubMed

    Ostojic, Sergej M; Mazic, Sanja

    2002-06-01

    The aim of this study was to examine the effects of a carbohydrate-electrolyte drink on specific soccer tests and performance. Twenty-two professional male soccer players volunteered to participate in the study. The players were allocated to two assigned trials ingesting carbohydrate-electrolyte drink (7% carbohydrates, sodium 24 mmol.l-1, chloride 12 mmol.l-1, potassium 3 mmol.l-1) or placebo during a 90 min on-field soccer match. The trials were matched for subjects' age, weight, height and maximal oxygen uptake. Immediately after the match, players completed four soccer-specific skill tests. Blood glucose concentration [mean (SD)] was higher at the end of the match-play in the carbohydrate-electrolyte trial than in the placebo trial (4.4 (0.3) vs. 4.0 (0.3) mmol.l-1, P < 0.05). Subjects in the carbohydrate-electrolyte trial finished the specific dribble test faster in comparison with subjects in the placebo trial (12.9 (0.4) vs. 13.6 (0.5) s, P < 0.05). Ratings of the precision test were higher in the carbohydrate-electrolyte trial as compared to the placebo trial (17.2 (4.8) vs. 15.1 (5.2), P < 0.05) but there were no differences in coordination test and power test results between trials. The main finding of the present study indicates that supplementation with carbohydrate-electrolyte solution improved soccer-specific skill performance and recovery after an on-field soccer match compared with ingestion of placebo. This suggests that soccer players should consume carbohydrate-electrolyte fluid throughout a game to help prevent deterioration in specific skill performance.

  15. Validity of critical frequency test for measuring table tennis aerobic endurance through specific protocol

    PubMed Central

    Zagatto, Alessandro M.; Papoti, Marcelo; Gobatto, Claudio A.

    2008-01-01

    The aim of this study was to validate critical frequency specific test (critf) for the estimation of the aerobic endurance in table tennis players. Methods: Eight male international-level table tennis players participated of this study. Specific tests were applied by using a mechanical ball thrower to control the intensity of the exercise. The critf was determined by applying three or four series of exercises to exhaustion (Tlim). The critf was evaluated by using lactate steady state test (90, 100, and 106 % of critf intensity). The other specific test was an incremental protocol used to determine the anaerobic threshold (AnTBI) and the onset of blood lactate accumulation (OBLA) using a ball thrower. Results: The critf (39.87 ± 3.31 balls·min-1) was not significantly different among AnTBI (48.11 ± 7.36 balls·min- 1) and OBLA3.5 (49.36 ± 12.04 balls·min-1) frequencies and it was correlated with AnTBI parameter (r = 0.78). At frequencies of the 90 and 100% of critf a dynamic equilibrium was verified in lactate concentration between the eighth and twentieth minutes. However, this dynamic equilibrium was not found at 106% intensity. Conclusion: The data indicate that in table tennis the critf model can be used for measuring the aerobic endurance. Key pointsIn table tennis is need the use of a specific protocol for evaluation of the aerobic endurance.The critical frequency test in table tennis seems to represent the intensity of maximal equilibrium of lactatemia.The critical frequency test can be used for measuring table tennis aerobic endurance through specific protocol. PMID:24149951

  16. California Verbal Learning Test Indicators of Malingered Neurocognitive Dysfunction: Sensitivity and Specificity in Traumatic Brain Injury

    ERIC Educational Resources Information Center

    Curtis, Kelly L.; Greve, Kevin W.; Bianchini, Kevin J.; Brennan, Adrianne

    2006-01-01

    The present study used well-defined traumatic brain injury (TBI) and mixed neurological (other than TBI) and psychiatric samples to examine the specificity and sensitivity to Malingered Neurocognitive Dysfunction (MND) of four individual California Verbal Learning Test (CVLT) variables and eight composite CVLT malingering indicators. Participants…

  17. 21 CFR 866.5540 - Immunoglobulin G (Fd fragment specific) immunological test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Immunoglobulin G (Fd fragment specific) immunological test system. 866.5540 Section 866.5540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... fragment) of the heavy chain (a subunit) of the immunoglobulin antibody molecule in serum. Measurement...

  18. 21 CFR 866.5530 - Immunoglobulin G (Fc fragment specific) immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Immunoglobulin G (Fc fragment specific) immunological test system. 866.5530 Section 866.5530 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... abnormalities, e.g., gamma heavy chain disease. (b) Classification. Class I (general controls). The device...

  19. 21 CFR 866.5540 - Immunoglobulin G (Fd fragment specific) immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Immunoglobulin G (Fd fragment specific) immunological test system. 866.5540 Section 866.5540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... fragment) of the heavy chain (a subunit) of the immunoglobulin antibody molecule in serum. Measurement...

  20. 21 CFR 866.5540 - Immunoglobulin G (Fd fragment specific) immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Immunoglobulin G (Fd fragment specific) immunological test system. 866.5540 Section 866.5540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... fragment) of the heavy chain (a subunit) of the immunoglobulin antibody molecule in serum. Measurement...

  1. 21 CFR 866.5530 - Immunoglobulin G (Fc fragment specific) immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Immunoglobulin G (Fc fragment specific) immunological test system. 866.5530 Section 866.5530 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... abnormalities, e.g., gamma heavy chain disease. (b) Classification. Class I (general controls). The device...

  2. 21 CFR 866.5540 - Immunoglobulin G (Fd fragment specific) immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Immunoglobulin G (Fd fragment specific) immunological test system. 866.5540 Section 866.5540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... fragment) of the heavy chain (a subunit) of the immunoglobulin antibody molecule in serum. Measurement...

  3. 21 CFR 866.5530 - Immunoglobulin G (Fc fragment specific) immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Immunoglobulin G (Fc fragment specific) immunological test system. 866.5530 Section 866.5530 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... abnormalities, e.g., gamma heavy chain disease. (b) Classification. Class I (general controls). The device...

  4. 75 FR 20832 - Environmental Management Site-Specific Advisory Board, Nevada Test Site

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    ...This notice announces a meeting of the Environmental Management Site-Specific Advisory Board (EM SSAB), Nevada Test Site. The Federal Advisory Committee Act (Pub. L. 92-463, 86 Stat. 770) requires that public notice of this meeting be announced in the Federal...

  5. Relationship between anaerobic parameters provided from MAOD and critical power model in specific table tennis test.

    PubMed

    Zagatto, A M; Gobatto, C A

    2012-08-01

    The aim of this study was to verify the validity of the curvature constant parameter (W'), calculated from 2-parameter mathematical equations of critical power model, in estimating the anaerobic capacity and anaerobic work capacity from a table tennis-specific test. Specifically, we aimed to i) compare constants estimated from three critical intensity models in a table tennis-specific test (Cf); ii) correlate each estimated W' with the maximal accumulated oxygen deficit (MAOD); iii) correlate each W' with the total amount of anaerobic work (W ANAER) performed in each exercise bout performed during the Cf test. Nine national-standard male table tennis players participated in the study. MAOD was 63.0(10.8) mL · kg - 1 and W' values were 32.8(6.6) balls for the linear-frequency model, 38.3(6.9) balls for linear-total balls model, 48.7(8.9) balls for Nonlinear-2 parameter model. Estimated W' from the Nonlinear 2-parameter model was significantly different from W' from the other 2 models (P<0.05). Also, none W' values were significantly correlated with MAOD or W ANAER (r ranged from - 0.58 to 0.51; P>0.13). Thus, W' estimated from the 2-parameter mathematical equations did not correlate with MAOD or W ANAER in table tennis-specific tests, indicating that W' may not provide a strong and valid estimation of anaerobic capacity and anaerobic capacity work.

  6. Interactions among Domain-Specific Expectancies, Values, and Gender: Predictors of Test Anxiety during Early Adolescence

    ERIC Educational Resources Information Center

    Selkirk, Laura C.; Bouchey, Heather A.; Eccles, Jacquelynne S.

    2011-01-01

    This research focuses on the interaction between students' domain-specific expectancies and values as a predictor of test anxiety. A subsample of adolescents from the MSALT dataset are used in the current study; students complete measures during the spring of sixth grade and again during the spring of seventh grade. Overall, findings provide…

  7. Testing a Bilinear Domain-Specific Model of Acculturation and Enculturation across Generational Status

    ERIC Educational Resources Information Center

    Miller, Matthew J.

    2010-01-01

    This study attempted to replicate Miller's (2007) finding that a bilinear domain-specific model of Asian American acculturation demonstrated superior model fit when compared to unilinear and bilinear domain-generic models. Current confirmatory factor analytic tests of competing acculturation models in a cross-validation sample of 306 participants…

  8. 12. "SITE PLAN." Test Area 1100. Specifications No. OC35973; Drawing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. "SITE PLAN." Test Area 1-100. Specifications No. OC359-73; Drawing No. 5841-C-1; D.O. SERIES AW1525/7 Rev. A. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA

  9. Using a Table of Specifications to Improve Teacher-Constructed Traditional Tests: An Experimental Design

    ERIC Educational Resources Information Center

    DiDonato-Barnes, Nicole; Fives, Helenrose; Krause, Emily S.

    2014-01-01

    We investigated if instruction on a Table of Specifications (TOS) would influence the quality of classroom test construction. Results should prove informative for educational researchers, teacher educators, and practising teachers interested in evidenced-based strategies that may improve assessment-related practices. Fifty-three college…

  10. Development of USES Specific Aptitude Test Battery for Ticket Agent (any ind.) 238.367-026.

    ERIC Educational Resources Information Center

    Utah State Dept. of Employment Security, Salt Lake City. Western Test Development Field Center.

    The United States Employment Service (USES) Specific Aptitude Test Battery (SATB) for Ticket Agent is evaluated from three points of view: (1) technical adequacy of the research; (2) fairness to minorities; and (3) usefulness of the battery to Employment Service staff and employers in selecting individuals for ticket agent positions. Research…

  11. Lead isotopic studies of lunar soils - Their bearing on the time scale of agglutinate formation

    NASA Technical Reports Server (NTRS)

    Church, S. E.; Tilton, G. R.; Chen, J. H.

    1976-01-01

    Fines (smaller than 75 microns) and bulk soil were studied to analyze loss of volatile lead; losses of the order of 10% to 30% radiogenic lead during the production of agglutinates are assessed. Lead isotope data from fine-agglutinate pairs are analyzed for information on the time scale of micrometeorite bombardment, from the chords generated by the data in concordia diagrams. Resulting mean lead loss ages were compared to spallogenic gas exposure ages for all samples. Labile parentless radiogenic Pb residing preferentially on or in the fines is viewed as possibly responsible for aberrant lead loss ages. Bulk soils plot above the concordia curve (in a field of excess radiogenic Pb) for all samples with anomalous ages.

  12. A specific polymerase chain reaction test for the identification of Streptococcus pneumoniae.

    PubMed

    Prère, Marie-Françoise; Fayet, Olivier A

    2011-05-01

    Using an approach based on the comparison of arbitrary primer polymerase chain reaction (PCR) genomic profiles from oral streptococci and Streptococcus pneumoniae strains, we identified a 434-bp genomic fragment apparently specific for S. pneumoniae. From the nucleotidic sequence of this common fragment, a pair of primers was designed and tested on a set of strains comprising the major Streptococcus species. One species, S. anginosus, gave an amplification product of the same length as S. pneumoniae. Sequence comparison of the S. anginosus and S. pneumoniae amplicons revealed several variations which were used to define a new set of primers giving a 181-bp S. pneumoniae-specific fragment. The amplified fragment contains the 5' terminal part of a gene encoding a putative sugar-specific permease and an intergenic sequence. The PCR test was evaluated on 257 strains of invasive S. pneumoniae corresponding to clinical isolates and on 153 non-pneumoniae oral streptococci strains; in addition, 3 S. pseudopneumoniae strains were tested. With these primers, an amplification product was only obtained with the S. pneumoniae strains. Moreover, the test was successfully evaluated on 10 atypical S. pneumoniae strains related to pneumococcal diseases. In this study, we therefore established the capacity of a simple PCR test to discriminate S. pneumoniae from other Streptococci (including S. pseudopneumoniae), thus allowing rapid and accurate diagnosis.

  13. McNemar chi2 test revisited: comparing sensitivity and specificity of diagnostic examinations.

    PubMed

    Trajman, A; Luiz, R R

    2008-01-01

    When evaluating a novel diagnostic examination for clinical use, it should be compared with a reference standard, defined as the best available examination, which may include clinical and laboratory criteria. The novel examination and reference standard's results are usually presented in the form of a 2 x 2 table, which allows calculation of sensitivity, specificity and accuracy. It has been recommended that the measures of statistical uncertainty should be reported, such as the 95% confidence interval, when evaluating the accuracy of diagnostic examinations. Comparing the difference in sensitivity or specificity of a novel examination with the reference standard is important when evaluating its usefulness. The McNemar chi(2) test, used to compare discordance of two dichotomous responses, can be applied for this purpose. However, applying the McNemar test to a 2 x 2 table for comparing the accuracy of examinations is not recommended, since this test is sensitive to the proportion of positive versus negative subjects. Moreover, if the novel examination has higher sensitivity than the one considered as the reference standard, constructing a classic 2 x 2 table would result in low specificity of the novel examination. Thus, in order to compare sensitivities and specificities between examinations, this table is inappropriate and an independent reference standard is necessary. In this article, we propose the use of the McNemar chi(2) test to compare sensitivities between examinations using a 2 x 2 table exclusively among diseased patients, defined by a set of criteria and follow-up of patients. Likewise, specificities can be compared applying the McNemar test among healthy individuals.

  14. The Rose Bengal Test in human brucellosis: a neglected test for the diagnosis of a neglected disease.

    PubMed

    Díaz, Ramón; Casanova, Aurora; Ariza, Javier; Moriyón, Ignacio

    2011-04-19

    Brucellosis is a highly contagious zoonosis affecting livestock and human beings. The human disease lacks pathognomonic symptoms and laboratory tests are essential for its diagnosis. However, most tests are difficult to implement in the areas and countries were brucellosis is endemic. Here, we compared the simple and cheap Rose Bengal Test (RBT) with serum agglutination, Coombs, competitive ELISA, Brucellacapt, lateral flow immunochromatography for IgM and IgG detection and immunoprecipitation with Brucella proteins. We tested 208 sera from patients with brucellosis proved by bacteriological isolation, 20 contacts with no brucellosis, and 1559 sera of persons with no recent contact or brucellosis symptoms. RBT was highly sensitive in acute and long evolution brucellosis cases and this related to its ability to detect IgM, IgG and IgA, to the absence of prozones, and to the agglutinating activity of blocking IgA at the pH of the test. RBT was also highly specific in the sera of persons with no contact with Brucella. No test in this study outperformed RBT, and none was fully satisfactory in distinguishing contacts from infected patients. When modified to test serum dilutions, a diagnostic titer >4 in RBT resulted in 87.4% sensitivity (infected patients) and 100% specificity (contacts). We discuss the limitations of serological tests in the diagnosis of human brucellosis, particularly in the more chronic forms, and conclude that simplicity and affordability of RBT make it close to the ideal test for small and understaffed hospitals and laboratories.

  15. The wrist hyperflexion and abduction of the thumb (WHAT) test: a more specific and sensitive test to diagnose de Quervain tenosynovitis than the Eichhoff's Test.

    PubMed

    Goubau, J F; Goubau, L; Van Tongel, A; Van Hoonacker, P; Kerckhove, D; Berghs, B

    2014-03-01

    De Quervain's disease has different clinical features. Different tests have been described in the past, the most popular test being the Eichhoff's test, often wrongly named as the Finkelstein's test. Over the years, a misinterpretation has occurred between these two tests, the latter being confused with the first. To compare the Eichhoff's test with a new test, the wrist hyperflexion and abduction of the thumb test, we set up a prospective study over a period of three years for a cohort of 100 patients (88 women, 12 men) presenting spontaneous pain over the radial side of the styloid of the radius (de Quervain tendinopathy). The purpose of the study was to compare the accuracy of the Eichhoff's test and wrist hyperflexion and abduction of the thumb test to diagnose correctly de Quervain's disease by comparing clinical findings using those tests with the results on ultrasound. The wrist hyperflexion and abduction of the thumb test revealed greater sensitivity (0.99) and an improved specificity (0.29) together with a slightly better positive predictive value (0.95) and an improved negative predictive value (0.67). Moreover, the study showed us that the wrist hyperflexion and abduction of the thumb test is very valuable in diagnosing dynamic instability after successful decompression of the first extensor compartment. Our results support that the wrist hyperflexion and abduction of the thumb test is a more precise tool for the diagnosis of de Quervain's disease than the Eichhoff's test and thus could be adopted to guide clinical diagnosis in the early stages of de Quervain's tendinopathy.

  16. Practice Effect and Normative Data of an HIV-specific Neuropsychological Testing Battery among Healthy Thais

    PubMed Central

    Sithinamsuwan, Pasiri; Hutchings, Nicholas; Ananworanich, Jintanat; Wendelken, Lauren; Saengtawan, Putthachard; Paul, Robert; Chomchey, Nitiya; Fletcher, James LK; Chalermchai, Thep; Valcour, Victor

    2015-01-01

    Objective A longitudinal cohort study was conducted in Bangkok, Thailand between 2008 and 2013 in order to determine the practice effect of serial neuropsychological testing and establish normative data among normal (HIV-uninfected) Thai volunteers. Material and Method The authors enrolled 511 cognitively healthy individuals (HIV-uninfected, no drug abuse or other previous/current neurological or psychological conditions) to assess baseline performance on a HIV-specific neuropsychological testing battery. Ninety-nine subjects were re-assessed at 6 and 12 months to evaluate practice effects. Results The mean age of the 99 subjects completing longitudinal visits was 49.2 years and 53 were male. The authors identified improved mean raw scores on most neuropsychological tests with repeated measurements; however, only change in WHO Auditory Verbal Learning Test (AVLT) scores (learning, attention, immediate and delayed recall tasks) met statistical significance, with larger differences seen between baseline and 6-month compared to 6 and 12 months follow-up. Older age correlated with poorer baseline raw score, and was a predictor of worse performance at 6 months and 12 months on several tasks. Level of education was associated with practice effects on several tests. No similar effects were observed with gender. Conclusion The authors identified improved performance after repeated measurements revealing a significant practice effect on an HIV-specific neuropsychological testing battery employed in Bangkok, Thailand. Main predictors were age and educational attainment. PMID:25518198

  17. Determination of Aerobic Power Through a Specific Test for Taekwondo - A Predictive Equation Model

    PubMed Central

    Louro, Hugo; Matias, Ricardo; Brito, João; Costa, Aldo M.

    2016-01-01

    Abstract Our aim was to verify the concurrent validity of a maximal taekwondo specific test (TST) to predict VO2max through an explanatory model. Seventeen elite male taekwondo athletes (age: 17.59 ± 4.34 years; body height: 1.72 ± 6.5 m; body mass: 61.3 ± 8.7 kg) performed two graded maximal exercise tests on different days: a 20 m multistage shuttle run test (SRT) and an incremental TST. We recorded test time, VO2max, ventilation, a heart rate and time to exhaustion. Significant differences were found between observed and estimated VO2max values [F (2, 16) = 5.77, p < 0.01]; post-hoc subgroup analysis revealed the existence of significant differences (p = 0.04) between the estimated VO2max value in the SRT and the observed value recorded in the TST (58.4 ± 6.4 ml/kg/min and 52.6 ± 5.2 ml/kg/min, respectively). Our analysis also revealed a moderate correlation between both testing protocols regarding VO2max (r = 0.70; p = 0.005), test time (r = 0.77; p = 0.02) and ventilation (r = 0.69; p = 0.03). There was no proportional bias in the mean difference (t = -1.04; p = 0.313), and there was a level of agreement between both tests. An equation/model was used to estimate VO2max during the TST based on the mean heart rate, test time, body height and mass, which explained 74.3% of the observed VO2max variability. A moderate correlation was found between the observed and predicted VO2max values in the taekwondo TST (r = 0.74, p = 0.001). Our results suggest that an incremental specific test estimates VO2max of elite taekwondo athletes with acceptable concurrent validity. PMID:28149417

  18. Determination of Aerobic Power Through a Specific Test for Taekwondo - A Predictive Equation Model.

    PubMed

    Rocha, Fernando P S; Louro, Hugo; Matias, Ricardo; Brito, João; Costa, Aldo M

    2016-12-01

    Our aim was to verify the concurrent validity of a maximal taekwondo specific test (TST) to predict VO2max through an explanatory model. Seventeen elite male taekwondo athletes (age: 17.59 ± 4.34 years; body height: 1.72 ± 6.5 m; body mass: 61.3 ± 8.7 kg) performed two graded maximal exercise tests on different days: a 20 m multistage shuttle run test (SRT) and an incremental TST. We recorded test time, VO2max, ventilation, a heart rate and time to exhaustion. Significant differences were found between observed and estimated VO2max values [F (2, 16) = 5.77, p < 0.01]; post-hoc subgroup analysis revealed the existence of significant differences (p = 0.04) between the estimated VO2max value in the SRT and the observed value recorded in the TST (58.4 ± 6.4 ml/kg/min and 52.6 ± 5.2 ml/kg/min, respectively). Our analysis also revealed a moderate correlation between both testing protocols regarding VO2max (r = 0.70; p = 0.005), test time (r = 0.77; p = 0.02) and ventilation (r = 0.69; p = 0.03). There was no proportional bias in the mean difference (t = -1.04; p = 0.313), and there was a level of agreement between both tests. An equation/model was used to estimate VO2max during the TST based on the mean heart rate, test time, body height and mass, which explained 74.3% of the observed VO2max variability. A moderate correlation was found between the observed and predicted VO2max values in the taekwondo TST (r = 0.74, p = 0.001). Our results suggest that an incremental specific test estimates VO2max of elite taekwondo athletes with acceptable concurrent validity.

  19. The Life Cycle of Entzia, an Agglutinated Foraminifer from the Salt Marshes in Transylvania

    NASA Astrophysics Data System (ADS)

    Kaminski, Michael; Telespan, Andreea; Balc, Ramona; Filipescu, Sorin; Varga, Ildiko; Görög, Agnes

    2013-04-01

    The small salt marshes associated with Miocene salt domes in Transylvania are host to a variety of marine organisms, including communities of halophytic plants as well as an agglutinated foraminifer that is normally found in coastal salt marshes worldwide. Originally described as the species Entzia tetrastoma by Daday (1884), the foraminifer is more widely known by the name Jadammina macrescens (Brady, 1870). Because the genus name Entzia has priority over Jadammina, the valid name of this taxon is Entzia macrescens (Brady, 1870). In 2007, we discovered a living population of Entzia inhabiting a small salt marsh just outside the town of Turda in central Transylvania, only a kilometer from the famous Maria Theresa Salt Mine. This is the first discovery of a living population of Entzia in Transylvania since the species was originally described in 1884. To determine whether or not the specimens we found represent a breeding population, samples were collected from the marsh on a monthly basis over the span of a year. This species can be found among the roots of the halophytic plants, in the uppermost one or two centimeters of the mud. Sediment samples were preserved in Vodka with Rose Bengal to distinguish living and dead specimens, and examined quantitatively. To document the life cycle of the species the following metrics were carried out: test size, abundance, number of chambers, ratio between live and dead specimens, and the diameter of the proloculus. An increase in the mean diameter of specimens was found from October to December. However the mean diameter decreased again in January, which suggests that asexual reproduction had apparently taken place. Small specimens again appeared in March, when sexual reproduction is presumed to have taken place. The median proloculus diameter was smallest in April and May, but the monthly changes in mean proloculus size within the population over the span of a year are not significant. However, specimens with largest

  20. Sensitivity and specificity of Ankara University Cerebral Dominance Inventory in comparison with the Wada test.

    PubMed

    Yılmaz, Nesrin Helvacı; Bingol, Ayse Petek

    2014-03-01

    We aimed to examine the sensitivity and specificity of the Ankara University Cerebral Dominance Inventory (AUCDI) in determining left cerebral dominance compared with the Wada test. The AUCDI and Wada test were applied to 49 patients referred to Ankara University for epilepsy surgery. Hand, foot and 'total' preference scores were specified according to the results of the inventory. Thirty-eight of the patients had left cerebral dominance and 11 had atypical cerebral dominance for language. 86 % of the patients were right-handed and 43 % were right-footed. When compared with the results of the Wada test, the sensitivity of the AUCDI for each 'total preference', and hand and foot preference was 90, 95 and 50 % and specificity was 46, 46 and 82 %, respectively. The percentage of right-footed patients was low when compared with the other studies. This difference might result from the method used for assessing foot preference by the actual demonstration of the task rather than just asking about the performance. The AUCDI was found to be sensitive in terms of 'total preference' and hand preference, and specific in terms of foot preference for determining the left hemisphere dominance in patients preferring the right side. It was a cheap and noninvasive alternative to the Wada test, appropriate for clinical bedside evaluation.

  1. The sensitivity and specificity of clinical measures of sport concussion: three tests are better than one

    PubMed Central

    Resch, Jacob E; Brown, Cathleen N; Schmidt, Julianne; Macciocchi, Stephen N; Blueitt, Damond; Cullum, C Munro; Ferrara, Michael S

    2016-01-01

    Context A battery of clinical measures of neurocognition, balance and symptoms has been recommended for the management of sport concussion (SC) but is based on variable evidence. Objective To examine the sensitivity and specificity of a battery of tests to assess SC in college athletes. Design Cross-sectional. Setting Research laboratory. Patients or other participants Division 1 athletes diagnosed with a SC (n=40) who were 20.2±1.60 years of age and 180.5±11.12 cm tall and healthy athletes (n=40) who were 19.0±0.93 years of age and 179.1±11.39 cm tall were enrolled. Intervention(s) Participants were administered Immediate Postconcussion Assessment and Cognitive Test (ImPACT), the Sensory Organization Test (SOT) and the Revised Head Injury Scale (HIS-r) prior to and up to 24 h following injury between the 2004 and 2014 sport seasons. Sensitivity and specificity were calculated using predictive discriminant analyses (PDA) and clinical interpretation guidelines. Main outcome measures Outcome measures included baseline and postinjury ImPACT, SOT and HIS-r composite scores. Results Using PDA, each clinical measure's sensitivity ranged from 55.0% to 77.5% and specificity ranged from 52.5% to 100%. The test battery possessed a sensitivity and specificity of 80.0% and 100%, respectively. Using clinical interpretation guidelines, sensitivity ranged from 55% to 97.5% individually, and 100% when combined. Conclusions Our results support a multidimensional approach to assess SC in college athletes which correctly identified 80–100% of concussed participants as injured. When each test was evaluated separately, up to 47.5% of our sample was misclassified. Caution is warranted when using singular measures to manage SC. PMID:27900145

  2. Involvement of cross-reactive carbohydrate determinants-specific IgE in pollen allergy testing

    PubMed Central

    Yoshitake, Hiroshi; Matsumoto, Yuma; Kawada, Michitsugu; Takato, Yoshiki; Shinagawa, Kiyomi; Sakurai, Hiroyuki; Saito, Koichiro

    2017-01-01

    Background Specific IgE antibodies against the low-molecular-weight carbohydrate antigen that does not bridge IgE molecules on mast cells are not associated with clinical symptoms. Cross reactivity can be determined in allergen-specific IgE detection assays when the carbohydrate structures between pollen allergens and plant derived food allergens are similar; in such cases, false positive results for grain or legume allergens can be reported for pollen allergic patients who are not sensitized to those allergens. This phenomenon arises owing to the presence of cross-reactive carbohydrate determinants (CCDs). Objective This study aimed to assess the impact of CCD interference on the results for pollen allergen-specific IgE antibodies in the general adult population and to perform CCD inhibition tests evaluating the involvement of CCD on samples positive to pollen allergens. Methods Serum samples from 322 subjects were tested for IgE antibodies to pollens and CCD. The research subjects were given questionnaires about pollen allergic symptoms to help assess the presence of allergies. Allergen IgE antibodies for Japanese cedar, Japanese cypress, orchard grass, ragweed, MUXF, bromelain, horseradish peroxidase (HRP), and ascorbate oxidase (ASOD) were analyzed. Results It was observed that among individuals who tested positive to any of the pollen allergens, the positive ratio of CCD-specific IgE antibody was the highest for HRP (13.5%–50.0%). The results from the inhibition tests revealed that CCD was marginally present. Although IgE antibodies for cedar pollen did not react with CCD, IgE antibodies for Japanese cypress, orchard grass, and ragweed might be detected by the presence of CCD. Conclusion The results of the inhibition tests revealed the obvious presence of CCD suggesting its involvement. Considering these findings, careful evaluation of patient IgE results should be performed for Japanese cypress, orchard grass, and ragweed. PMID:28154803

  3. Specificity data for the b Test, Dot Counting Test, Rey-15 Item Plus Recognition, and Rey Word Recognition Test in monolingual Spanish-speakers.

    PubMed

    Robles, Luz; López, Enrique; Salazar, Xavier; Boone, Kyle B; Glaser, Debra F

    2015-01-01

    The current study provides specificity data on a large sample (n = 115) of young to middle-aged, male, monolingual Spanish speakers of lower educational level and low acculturation to mainstream US culture for four neurocognitive performance validity tests (PVTs): the Dot Counting, the b Test, Rey Word Recognition, and Rey 15-Item Plus Recognition. Individuals with 0 to 6 years of education performed more poorly than did participants with 7 to 10 years of education on several Rey 15-Item scores (combination equation, recall intrusion errors, and recognition false positives), Rey Word Recognition total correct, and E-score and omission errors on the b Test, but no effect of educational level was observed for Dot Counting Test scores. Cutoff scores are provided that maintain approximately 90% specificity for the education subgroups separately. Some of these cutoffs match, or are even more stringent than, those recommended for use in US test takers who are primarily Caucasian, are tested in English, and have a higher educational level (i.e., Rey Word Recognition correct false-positive errors; Rey 15-Item recall intrusions and recognition false-positive errors; b Test total time; and Dot Counting E-score and grouped dot counting time). Thus, performance on these PVT variables in particular appears relatively robust to cultural/language/educational factors.

  4. Test and verification of a reactor protection system application-specific integrated circuit

    SciTech Connect

    Battle, R.E.; Turner, G.W.; Vandermolen, R.I.; Vitalbo, C.; Naser, J.

    1997-03-01

    Application-specific integrated circuits (ASICs) were utilized in the design of nuclear plant safety systems because they have certain advantages over software-based systems and analog-based systems. An advantage they have over software-based systems is that an ASIC design can be simple enough to not include branch statements and also can be thoroughly tested. A circuit card on which an ASIC is mounted can be configured to replace various versions of older analog equipment with fewer design types required. The approach to design and testing of ASICs for safety system applications is discussed in this paper. Included are discussions of the ASIC architecture, how it is structured to assist testing, and of the functional and enhanced circuit testing.

  5. Specific wavelength colorimeter. [for measuring given solute concentration in test sample

    NASA Technical Reports Server (NTRS)

    Brawner, C. C.; Mcdavid, L. S.; Walsh, J. M. (Inventor)

    1974-01-01

    A self contained, specific wavelength, single beam colorimeter is described for direct spectrophotometric measurement of the concentration of a given solute in a test sample. An electrical circuit employing a photoconductive cell converts the optical output into a linear, directly readable meter output. The colorimeter is simple to operate and is adapted for use in zero gravity conditions. In a specific application, the colorimeter is designed to analyze the concentration of iodine in potable water carried aboard a space vehicle such as the 4B stage of Skylab.

  6. Genome-wide association filtering using a highly locus-specific transmission/disequilibrium test.

    PubMed

    Abad-Grau, María M; Medina-Medina, Nuria; Montes-Soldado, Rosana; Moreno-Ortega, José; Matesanz, Fuencisla

    2010-09-01

    Multimarker transmission/disequilibrium tests (TDTs) are powerful association and linkage tests used to perform genome-wide filtering in the search for disease susceptibility loci. In contrast to case/control studies, they have a low rate of false positives for population stratification and admixture. However, the length of a region found in association with a disease is usually very large because of linkage disequilibrium (LD). Here, we define a multimarker proportional TDT (mTDT ( P )) designed to improve locus specificity in complex diseases that has good power compared to the most powerful multimarker TDTs. The test is a simple generalization of a multimarker TDT in which haplotype frequencies are used to weight the effect that each haplotype has on the whole measure. Two concepts underlie the features of the metric: the 'common disease, common variant' hypothesis and the decrease in LD with chromosomal distance. Because of this decrease, the frequency of haplotypes in strong LD with common disease variants decreases with increasing distance from the disease susceptibility locus. Thus, our haplotype proportional test has higher locus specificity than common multimarker TDTs that assume a uniform distribution of haplotype probabilities. Because of the common variant hypothesis, risk haplotypes at a given locus are relatively frequent and a metric that weights partial results for each haplotype by its frequency will be as powerful as the most powerful multimarker TDTs. Simulations and real data sets demonstrate that the test has good power compared with the best tests but has remarkably higher locus specificity, so that the association rate decreases at a higher rate with distance from a disease susceptibility or disease protective locus.

  7. Genome-wide association filtering using a highly locus-specific transmission/disequilibrium test

    PubMed Central

    Medina-Medina, Nuria; Montes-Soldado, Rosana; Moreno-Ortega, José; Matesanz, Fuencisla

    2010-01-01

    Multimarker transmission/disequilibrium tests (TDTs) are powerful association and linkage tests used to perform genome-wide filtering in the search for disease susceptibility loci. In contrast to case/control studies, they have a low rate of false positives for population stratification and admixture. However, the length of a region found in association with a disease is usually very large because of linkage disequilibrium (LD). Here, we define a multimarker proportional TDT (mTDTP) designed to improve locus specificity in complex diseases that has good power compared to the most powerful multimarker TDTs. The test is a simple generalization of a multimarker TDT in which haplotype frequencies are used to weight the effect that each haplotype has on the whole measure. Two concepts underlie the features of the metric: the ‘common disease, common variant’ hypothesis and the decrease in LD with chromosomal distance. Because of this decrease, the frequency of haplotypes in strong LD with common disease variants decreases with increasing distance from the disease susceptibility locus. Thus, our haplotype proportional test has higher locus specificity than common multimarker TDTs that assume a uniform distribution of haplotype probabilities. Because of the common variant hypothesis, risk haplotypes at a given locus are relatively frequent and a metric that weights partial results for each haplotype by its frequency will be as powerful as the most powerful multimarker TDTs. Simulations and real data sets demonstrate that the test has good power compared with the best tests but has remarkably higher locus specificity, so that the association rate decreases at a higher rate with distance from a disease susceptibility or disease protective locus. PMID:20603721

  8. Test and evaluation document for DOT Specification 7A Type A Packaging. Revision 3

    SciTech Connect

    1996-01-30

    The US Department of Energy (DOE) has been conducting, through several of its operating contractors, an evaluation and testing program to qualify Type A radioactive material packagings per US Department of Transportation (DOT) Specification 7A (DOT-7A) of the Code of Federal Regulations (CFR), Title 49, Part 178 (49 CFR 178). The program is currently administered by the DOE, Office of Facility Safety Analysis, DOE/EH-32, at DOE-Headquarters (DOE-HQ) in Germantown, Maryland. This document summarizes the evaluation and testing performed for all of the packagings successfully qualified in this program.

  9. The sensitivity and specificity of postbreeding plasma progesterone levels as a pregnancy test for dairy cows.

    PubMed Central

    Montgomery, M E; Leslie, K E; Martin, S W

    1985-01-01

    Plasma progesterone levels on day 4 and day 8 postbreeding were measured for one hundred and eighty-four dairy cows. These two parameters (PPD4, PPD8), their absolute difference (PPDIFF) and their ratio (PPRATIO) were assessed for their ability to identify cows not conceiving, using the principles of sensitivity and specificity. PPD4 was significantly higher (p less than 0.10) and PPD8, PPDIFF and PPRATIO were significantly lower (p less than 0.01) in cows remaining open than in pregnant cows. Evaluating each parameter separately, PPDIFF greater than 3.00 units had the highest specificity, 85.7%, but a low sensitivity (27.0%). Combining two parameters using series interpretation to increase specificity resulted in the best combination of specificity (87%) and sensitivity (27%). Maximum specificity was 97% for PPD4 less than or equal to 1.00 units and PPD8 greater than 4.00 units, and also for PPD4 less than or equal to 1.00 units and PPDIFF greater than 3.00 units, but sensitivity was very low (7% and 10% respectively). Predictive values of the test results with the best specificity were evaluated; given the population pregnancy rate of 54%, none exceeded 50%, indicating that the plasma progesterone parameters were not very useful for identifying open dairy cows. PMID:4041979

  10. Use of recombinant purified protein derivative (PPD) antigens as specific skin test for tuberculosis

    PubMed Central

    Stavri, Henriette; Bucurenci, Nadia; Ulea, Irina; Costache, Adriana; Popa, Loredana; Popa, Mircea Ioan

    2012-01-01

    Background & objectives: Purified protein derivative (PPD) is currently the only available skin test reagent used worldwide for the diagnosis of tuberculosis (TB). The aim of this study was to develop a Mycobacterium tuberculosis specific skin test reagent, without false positive results due to Bacillus Calmette-Guerin (BCG) vaccination using recombinant antigens. Methods: Proteins in PPD IC-65 were analyzed by tandem mass spectrometry and compared to proteins in M. tuberculosis culture filtrate; 54 proteins were found in common. Top candidates MPT64, ESAT 6, and CFP 10 were overexpressed in Escherichia coli expression strains and purified as recombinant proteins. To formulate optimal immunodiagnostic PPD cocktails, the antigens were evaluated by skin testing guinea pigs sensitized with M. tuberculosis H37Rv and BCG. Results: For single antigens and a cocktail mixture of these antigens, best results were obtained using 3 μg/0.1 ml, equivalent to 105 TU (tuberculin units). Each animal was simultaneously tested with PPD IC-65, 2 TU/0.1 ml, as reference. Reactivity of the multi-antigen cocktail was greater than that of any single antigen. The skin test results were between 34.3 and 76.6 per cent the level of reactivity compared to that of the reference when single antigens were tested and 124 per cent the level of reactivity compared to the reference for the multi-antigen cocktail. Interpretation & conclusions: Our results showed that this specific cocktail could represent a potential candidate for a new skin diagnostic test for TB. PMID:23287127

  11. Retesting The Validity Of A Specific Field Test For Judo Training

    PubMed Central

    Santos, Luis; González, Vicente; Iscar, Marta; Brime, Juan I.; Fernández-Río, Javier; Rodríguez, Blanca; Montoliu, Mª Ángeles

    2011-01-01

    The main goal of this research project was to retest the validity of a specifically designed judo field test (Santos Test) in a different group of judokas. Eight (n=8) national-level male judokas underwent laboratory and field testing. The mean data (mean +/− SD) obtained in the laboratory tests was: HRmax: 200 ± 4.0 beats × min−1, VO2 max: 52.8 ± 7.9 ± ml × kg−1 × min−1, lactate max: 12 ± 2.5 mmol × l−1, HR at the anaerobic threshold: 174.2 ± 9.4 beats × min−1, percentage of maximum heart rate at which the anaerobic threshold appears: 87 ± 3.6 %, lactate threshold: 4.0 ± 0.2 mmol × l−1, and RPE: 17.2 ± 1.0. The mean data obtained in the field test (Santos) was: HRmax: 201.3 ± 4.1 beats × min−1, VO2 max: 55.6 ± 5.8 ml × kg−1 × min−1, lactate max: 15.6 ± 2.8 mmol × l−1, HR at the anaerobic threshold: 173.2 ± 4.3 beats × min−1, percentage of maximum heart rate at which the anaerobic threshold appears: 86 ± 2.5 %, lactate threshold: 4.0 ± 0.2 mmol × l−1, and RPE: 16.7 ± 1.0. There were no significant differences between the data obtained on both tests in any of the parameters, except for maximum lactate concentration. Therefore, the Santos test can be considered a valid tool specific for judo training. PMID:23486994

  12. The role of specific emotions in children's responses to interparental conflict: a test of the model.

    PubMed

    Crockenberg, S; Langrock, A

    2001-06-01

    Mothers, fathers, and their 6-year-old children (N = 164) participated in a study testing key tenets of the specific emotions model of marital conflict. Parents reported their marital conflict strategies, were observed interacting with their children, and rated children's behavioral adjustment. Children reported their emotional reactions to specific interparental conflicts. Results support the specific emotions model. Children's behaviors mirrored the marital or parental behaviors of same-gender parents. Indirect effects of marital aggression through parental behavior were detected, and marital and parental behaviors interacted to predict girls' externalizing. Girls' anger, sadness, and fear increased with fathers' marital aggression. Fear and the anger by fear interaction predicted girls' internalizing. Fathers' marital aggression interacted with anger to predict externalizing and interacted with fear to predict internalizing behavior in boys.

  13. A test of the cognitive content specificity hypothesis in depression and anxiety.

    PubMed

    Lamberton, Anna; Oei, Tian P S

    2008-03-01

    The present study tested the cognitive content specificity hypothesis (CCSH) to assess whether anxiety and depression can be differentiated on the basis of cognitive disturbance. One hundred and thirty five depressed participants were administered the Beck depression inventory (BDI), the Beck anxiety inventory (BAI), the automatic thoughts questionnaire (ATQ) and the anxious self-statements questionnaire (ASSQ). It was hypothesised that depressive cognitions would be specifically related to, and predictive of, depressive (but not anxiety) symptoms in a depressed sample. Conversely, it was predicted that anxiety cognitions would be specifically related to, and predictive of, anxiety (but not depressive) symptoms in a depressed sample. Results revealed that the ATQ was the sole predictor of the BDI and similarly, the ASSQ was the sole predictor of the BAI. These findings support the CCSH in depression and provide an integrative framework for a greater understanding of the relationship between anxiety and depression.

  14. Acoustic specifications for the design of jet engine test facilities on an airbase

    SciTech Connect

    Strumpf, F.M.

    1982-01-01

    The use of engine run up test arrangements was common in Israeli air-bases since the forties, when engines for the Mustang, Mosquito, Harward and other propellor powered planes were used. The era of jet engine propulsion boosted the noise levels, and the use of fighters with afterburners in the new engines of the 80's brought it up to unbearable levels. Thus, the growth of the Israeli Air Force demanded the use of efficient noise suppression devices. These were divided into engine run-up noise suppressors, and aircraft noise suppessors (Hush Houses). For both of the bove ground arrangements, acoustic specifications had to be given. They were, as well as design goals for the manufacturers, also needed to restrict noise levels on the air-base as well as its surroundings. The acoustic specifications discussed are based on measured data, and permitted noise levels in the homes on the base being as far as 2500 meters from the engine exhaust silencer. For the special air-base discussed, various criteria were tested, including US Military Specifications, none of which were acceptable, and a special specification was therefore prepared.

  15. 90/10 JP5/Synthesized ISO-Paraffin Specification and Fit-for-Purpose Test Results

    DTIC Science & Technology

    2014-06-11

    90/10 JP5/SYNTHESIZED ISO -PARAFFIN SPECIFICATION AND FIT-FOR-PURPOSE TEST RESULTS NAVAIR SYSCOM REPORT 441/14-010 11 June 2014 Prepared By...3 3.1 Synthesized Iso -Paraffins (SIP) Procurement Specification Test Results...26 Appendix A: Procurement Specification for Synthesized Iso -Paraffins (SIP) ........................... A-1

  16. Developing a Non-Language Related Span Test for the Use in Language-Specific and Cross-Language Studies

    ERIC Educational Resources Information Center

    Shahnazari-Dorcheh, Mohammadtaghi; Roshan, Saeed

    2012-01-01

    Due to the lack of span test for the use in language-specific and cross-language studies, this study provides L1 and L2 researchers with a reliable language-independent span test (math span test) for the measurement of working memory capacity. It also describes the development, validation, and scoring method of this test. This test included 70…

  17. Status and specifications of a Project X front-end accelerator test facility at Fermilab

    SciTech Connect

    Steimel, J.; Webber, R.; Madrak, R.; Wildman, D.; Pasquinelli, R.; Evans-Peoples, E.; /Fermilab

    2011-03-01

    This paper describes the construction and operational status of an accelerator test facility for Project X. The purpose of this facility is for Project X component development activities that benefit from beam tests and any development activities that require 325 MHz or 650 MHz RF power. It presently includes an H- beam line, a 325 MHz superconducting cavity test facility, a 325 MHz (pulsed) RF power source, and a 650 MHz (CW) RF power source. The paper also discusses some specific Project X components that will be tested in the facility. Fermilab's future involves new facilities to advance the intensity frontier. In the early 2000's, the vision was a pulsed, superconducting, 8 GeV linac capable of injecting directly into the Fermilab Main Injector. Prototyping the front-end of such a machine started in 2005 under a program named the High Intensity Neutrino Source (HINS). While the HINS test facility was being constructed, the concept of a new, more versatile accelerator for the intensity frontier, now called Project X, was forming. This accelerator comprises a 3 GeV CW superconducting linac with an associated experimental program, followed by a pulsed 8 GeV superconducting linac to feed the Main Injector synchrotron. The CW Project X design is now the model for Fermilab's future intensity frontier program. Although CW operation is incompatible with the original HINS front-end design, the installation remains useful for development and testing many Project X components.

  18. Proposal of a New Specific Cardiopulmonary Exercise Test for Taekwondo Athletes.

    PubMed

    Araujo, Marcus P; Nóbrega, Antônio C L; Espinosa, Gabriel; Hausen, Matheus; Castro, Renata R T; Soares, Pedro P; Gurgel, Jonas L

    2015-12-18

    The objective of this study is to evaluate the cardiorespiratory variables of Taekwondo athletes while performing incremental exercise test on ergometer using a ramp protocol and to propose a specific protocol for assessing these physiological variables during Taekwondo practice. Fourteen athletes participated in two incremental exercise tests: a treadmill exercise test (TREADtest) and a Taekwondo-specific exercise test (TKDtest). The TKDtest consists in one-minute stages of kicks with an incremental load between then. The subjects perform kicks each time a sound signal was heard. Heart rate (HR), oxygen uptake (V[Combining Dot Above]O2), and their reserve correspondents (V[Combining Dot Above]O2R and HRR) were divided into quartiles to verify their kinetics along the tests. Significant difference between two tests was found only for V[Combining Dot Above]O2R (p = 0.03). Regarding the quartiles, significant differences were found for HR in the 1 (p = 0.030) and 2 (p = 0.003). Analyzing the regression curves, significant differences were found for HR for intercept (p = 0.01) and slope (p = 0.05) and HRR for slope (p = 0.02). Analysis showed significant reliability, with intraclass correlation coefficient (ICC), was found for the V[Combining Dot Above]O2PEAK (ICC = 0.855, p = 0.003), V[Combining Dot Above]O2 in ventilatory thresholds 1 (ICC = 0.709, p = 0.03) and 2 (ICC = 0.848, p = 0.003). Bland-Altman analyses reported a mean difference ± the 95% limits of agreement of 2.2 ± 8.4 ml.kg.min to V[Combining Dot Above]O2PEAK. TKDtest is reliable for measurement of cardiorespiratory variables, and the behavior of these variables differs mainly from TREADtest, probably due to the motor task performed.

  19. SpA, ClfA, and FnbA Genetic Variations Lead to Staphaurex Test-Negative Phenotypes in Bovine Mastitis Staphylococcus aureus Isolates▿

    PubMed Central

    Stutz, Katrin; Stephan, Roger; Tasara, Taurai

    2011-01-01

    Staphylococcus aureus encodes many proteins that act as virulence factors, leading to a variety of diseases, including mastitis in cows. Among these virulence factors, SpA, ClfA, ClfB, FnbA, and FnbB are important for the ability of S. aureus to adhere to and invade host cells as well as to evade host immune responses. The interaction between these S. aureus surface proteins and human immunoglobulin G and fibrinogen that are coupled to latex particles is utilized to induce latex agglutination reactions, which are used widely in diagnostic kits for confirmation of presumptive S. aureus isolates. In this study, the Staphaurex latex agglutination test was performed on a collection of confirmed bovine mastitis S. aureus isolates. Notably, 54% (43/79 isolates) of these isolates exhibited latex agglutination-negative phenotypes (Staphaurex-negative result). To gain insights into the reasons for the high frequency of Staphaurex-negative bovine mastitis S. aureus isolates, the spa, clfA, clfB, fnbA, and fnbB genes were examined. Specific genetic changes in spa, clfA, and fnbA, as well as a loss of fnbB, which may impair SpA, ClfA, FnbA, and FnbB functions in latex agglutination reactions, were detected in Staphaurex-negative S. aureus isolates. The genetic changes included a premature stop codon in the spa gene, leading to a truncated SpA protein that is unable to participate in S. aureus cell-mediated agglutination of latex particles. In addition, clfA and fnbA genetic polymorphisms were detected that were linked to ClfA and FnbA amino acid changes that may significantly reduce fibrinogen-binding activity. The genetic variations in these S. aureus isolates might also have implications for their bovine mastitis virulence capacity. PMID:21147952

  20. Specificity of leucocyte migration inhibition test in coeliac disease. A reassessment using different gluten subfractions.

    PubMed Central

    Corazza, G R; Rawcliffe, P M; Frisoni, M; Sarchielli, P; Londei, M; Campieri, M; Lazzari, R; Gasbarrini, G

    1985-01-01

    Production of leucocyte migration inhibition factor by peripheral blood leucocytes in response to challenge with gluten fractions has been proposed as a reliable in vitro test for the diagnosis of coeliac disease. We have performed the leucocyte migration inhibition test with two different gluten fractions, GFIII and B2, in untreated and treated coeliac patients, patients with other intestinal diseases (abnormal controls) and healthy controls, and evaluated the sensitivity, specificity and positive and negative predictability of the test for the diagnosis of coeliac disease. Using GFIII as antigen leucocyte migration was significantly inhibited, compared to healthy controls, not only in treated and untreated coeliacs but also in abnormal controls. Using B2 gluten subfraction as antigen only treated coeliacs and abnormal controls differed significantly from healthy controls. The elevated number of abnormal controls showing migration inhibition consistently affected the diagnostic value of the test, which did not vary using B2 subfraction instead of GFIII as antigen. Our study confirms previous observations of gluten sensitization, as detected by leucocyte migration inhibition, in coeliac patients but strongly questions the claim that coeliac disease can be diagnosed on the basis of a positive leucocyte migration inhibition test without the need for intestinal biopsy. PMID:4006297

  1. Predictive value of specific ultrasound findings when used as a screening test for abnormalities on VCUG

    PubMed Central

    Logvinenko, Tanya; Chow, Jeanne S.; Nelson, Caleb P.

    2015-01-01

    Summary Background Renal and bladder ultrasound (RBUS) is often used as an initial screening test for children after urinary tract infection (UTI). The 2011 AAP guidelines specifically recommend that RBUS be performed first, with voiding cystourethrogram (VCUG) to be performed only if the ultrasound is abnormal. While prior research has suggested that RBUS is neither sensitive nor specific for VCUG findings, such as vesicoureteral reflux (VUR), it is uncertain as to whether specific RBUS findings, alone or in combination, might make RBUS more useful as a predictor of VCUG abnormalities. Aims To evaluate the association of specific RBUS with VCUG findings, and determine whether predictive models that accurately predict patients at high risk of VCUG abnormalities, based on RBUS findings, can be constructed. Methods and study sample A total of 3995 patients were identified with VCUG and RBUS performed on the same day. The RBUS and VCUG reports were reviewed and the findings were classified. Analysis was limited to patients aged 0–60 months with no prior postnatal genitourinary imaging and no history of prenatal hydronephrosis. Analysis The associations between large numbers of specific RBUS findings with abnormalities seen on VCUG were investigated. Both multivariate logistic models and a neural network machine learning algorithms were constructed to evaluate the predictive power of RBUS for VCUG abnormalities (including VUR or bladder/urethral findings). Sensitivity, specificity, predictive values and area under receiving operating curves (AUROC) of RBUS for VCUG abnormalities were determined. Results A total of 2259 patients with UTI as the indication for imaging were identified. The RBUS was reported as “normal” in 75.0%. On VCUG, any VUR was identified in 41.7%, VUR grade >II in 20.9%, and VUR grade >III in 2.8%. Many individual RBUS findings were significantly associated with VUR on VCUG. Despite these strong univariate associations, multivariate modeling

  2. Development and testing of biosensors that quantitatively and specifically detect organic contaminants

    SciTech Connect

    Jackson, P.; Keim, P.; Kuske, C.; Willardson, B.

    1996-07-01

    This is the final report of a two-year Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The project sought to develop a more sensitive and less expensive method of detecting organic contaminants. Assaying complex environmental samples for organic contaminant content is costly and labor intensive. This often limits extensive testing. Sensitive microbial biosensors that detect specific organic contaminants in complex waste mixtures without prior separation from other waste components have been developed. Some soil microbes degrade organic compounds that contaminate the environment. These bacteria sense minute quantities of particular organic compounds then respond by activating genes encoding enzymes that degrade these molecules. Genetic manipulation of these gene regulatory processes has been employed to develop unique biosensors that detect specific organic compounds using standard biochemical assays. Such biosensors allow rapid, sensitive testing of environmental samples for selected organic contaminants. The cost of biosensor assays is at least 100-fold less than present methods, allowing more rapid and extensive testing and site characterization.

  3. Factors affecting sensitivity and specificity of a diagnostic test: the exercise thallium scintigram

    SciTech Connect

    Detrano, R.; Janosi, A.; Lyons, K.P.; Marcondes, G.; Abbassi, N.; Froelicher, V.F.

    1988-04-01

    Technical and methodological factors might affect the reported accuracies of diagnostic tests. To assess their influence on the accuracy of exercise thallium scintigraphy, the medical literature (1977 to 1986) was non-selectively searched and meta-analysis was applied to the 56 publications thus retrieved. These were analyzed for year of publication, sex and mean age of patients, percentage of patients with angina pectoris, percentage of patients with prior myocardial infarction, percentage of patients taking beta-blocking medications, and for angiographic referral (workup) bias, blinding of tests, and technical factors. The percentage of patients with myocardial infarction had the highest correlation with sensitivity (0.45, p = 0.0007). Only the inclusion of subjects with prior infarction and the percentage of men in the study group were independently and significantly (p less than 0.05) related to test sensitivity. Both the presence of workup bias and publication year adversely affected specificity (p less than 0.05). Of these two factors, publication year had the strongest association by stepwise linear regression. This analysis suggests that the reported sensitivity of thallium scintigraphy is higher and the specificity lower than that expected in clinical practice because of the presence of workup bias and the inappropriate inclusion of post-infarct patients.

  4. Proposal for a Specific Aerobic Test for Football Players: The “Footeval”

    PubMed Central

    Manouvrier, Christophe; Cassirame, Johan; Ahmaidi, Saïd

    2016-01-01

    The aim of this study was to evaluate the reproducibility and validity of the “Footeval” test, which evaluates football players’ aerobic level in conditions close to those of football practice (intermittent, including technical skills). Twenty-four highly trained subjects from an elite football academy (17.8 ± 1.4 years, 5 training sessions per week) performed two Footeval sessions in a period of 7 days. Physiological variables measured during these sessions (VO2max 58.1 ± 5.6 and 58.7 ± 6.2 ml·min-1·kg-1; RER 1.18 ± 0.06 and 1.19 ± 0.05; LaMax 11.0 ±1.4 and 10.8 ±1.1 µmol·L-1; HRmax 194 ± 6 and 190 ± 7 b·min-1; Final step 10.71 ± 1.2 and 10.83 ± 1.13 and the RPE = 10) highlighted maximal intensity and confirmed that players reached physiological exhaustion. Comparison of values measured in both sessions showed large to very large correlations (Final level; 0.92, VO2max; 0.79, HRmax; 0.88, LaMax; 0.87) and high ICC (Final level; 0.93, VO2max; 0.87, HRmax; 0.90, LaMax; 0.85) except for RER (r = 0.22, ICC = 0.21). In addition, all subjects performed a time limit (Tlm) exercise with intensity set at maximal aerobic specific speed + 1 km·h-1, in order to check the maximal value obtained during the Footeval test. Statistical analysis comparing VO2max, HRmax and RER from the Footeval and Tlm exercise proved that values from Footeval could be considered as maximal values (r for VO2max; 0.82, HRmax; 0.77 and ICC for VO2max; 0.92, HRmax; 0.91). This study showed that Footeval is a reproducible test that allows maximal aerobic specific speed to be obtained at physiological exhaustion. Moreover, we can also affirm that this test meets the physiological exhaustion criteria as defined in the literature (RER ≥ 1, 1; LaMax ≥ 8 µmol·L-1; HR = HRmax; no increase of VO2 despite the increase of speed; RPE =10). Key points “Footeval” is a new test for football that is able to evaluate aerobic capacity in football specific conditions. This study

  5. Nanoscale Mineralogy and Composition of Experimental Regolith Agglutinates Produced under Asteroidal Impact Conditions

    NASA Technical Reports Server (NTRS)

    Christoffersen, Roy; Cintala, M. J.; Keller, L. P.; See, T. H.; Horz, F.

    2013-01-01

    On the Moon, the energetics of smaller impactors and the physical/chemical characteristics of the granular regolith target combine to form a key product of lunar space weathering: chemically reduced shock melts containing optically-active nanophase Fe metal grains (npFe0) [1]. In addition to forming the optically dark glassy matrix phase in lunar agglutinitic soil particles [1], these shock melts are becoming increasingly recognized for their contribution to optically active patina coatings on a wide range of exposed rock and grain surfaces in the lunar regolith [2]. In applying the lessons of lunar space weathering to asteroids, the potential similarities and differences in regolith-hosted shock melts on the Moon compared to those on asteroids has become a topic of increasing interest [3,4]. In a series of impact experiments performed at velocities applicable to the asteroid belt [5], Horz et al. [6] and See and Horz [7] have previously shown that repeated impacts into a gabbroic regolith analog target can produce melt-welded grain aggregates morphologically very similar to lunar agglutinates [6,7]. Although these agglutinate-like particles were extensively analyzed by electron microprobe and scanning electron microscopy (SEM) as part of the original study [7], a microstructural and compositional comparison of these aggregates to lunar soil agglutinates at sub-micron scales has yet to be made. To close this gap, we characterized a representative set of these aggregates using a JEOL 7600 field-emission scanning electron microscope (FE-SEM), and JEOL 2500SE field-emission scanning transmission electron microscope (FE-STEM) both optimized for energy dispersive X-ray spectroscopy (EDX) compositional spectrum imaging at respective analytical spatial resolutions of 0.5 to 1 micron, and 2 to 4 nm.

  6. 'No man is an island'. Testing the specific role of social isolation in formal thought disorder.

    PubMed

    de Sousa, Paulo; Spray, Amy; Sellwood, William; Bentall, Richard P

    2015-12-15

    Recent work has focused on the role of the environment in psychosis with emerging evidence that specific psychotic experiences are associated with specific types of adversity. One risk factor that has been often associated with psychosis is social isolation, with studies identifying isolation as an important feature of prodromal psychosis and others reporting that social networks of psychotic patients are smaller and less dense than those of healthy individuals. In the present study, we tested a prediction that social isolation would be specifically associated with formal thought disorder. 80 patients diagnosed with psychosis-spectrum disorder and 30 healthy participants were assessed for formal thought disorder with speech samples acquired during an interview that promoted personal disclosure and an interview targeting everyday topics. Social isolation was significantly associated with formal thought disorder in the neutral interview and in the salient interview, even when controlling for comorbid hallucinations, delusions and suspiciousness. Hallucinations, delusions and suspiciousness were not associated with social isolation when formal thought disorder was controlled for. Formal thought disorder is robustly and specifically associated with social isolation. Social cognitive mechanisms and processes are discussed which may explain this relationship as well as implications for clinical practice and future research.

  7. A Beverage-Specific Measure of Expectancies for Malt Liquor: Development and Initial Testing

    PubMed Central

    Collins, R. Lorraine; Vincent, Paula C.; Bradizza, Clara M.; Kubiak, Audrey J.; Falco, Diana L.

    2011-01-01

    Malt liquor (ML) is a unique, high alcohol content beverage marketed to encourage heavy drinking. We developed the Malt Liquor Expectancy Questionnaire (MLEQ), a beverage-specific measure of alcohol expectancies and examined its association with ML use, total alcohol use and alcohol problems. Forty positive and 40 negative expectancy items were administered to a sample of 639 young adults who regularly consumed ML. Exploratory and confirmatory factor analyses led to the development of the 30-item MLEQ. The MLEQ consists of two positive (i.e., Social Facilitation and Enjoyment, Enhanced Sexuality) and two negative factors (i.e., Aggression and Negative Consequences; Impairment and Physical Symptoms) that possess good internal consistency, test-retest reliability, and convergent validity. The psychometrically sound MLEQ contributes to the limited research on beverage-specific expectancies and heavy drinking. PMID:21928870

  8. A beverage-specific measure of expectancies for malt liquor: development and initial testing.

    PubMed

    Collins, R Lorraine; Vincent, Paula C; Bradizza, Clara M; Kubiak, Audrey J; Falco, Diana L

    2011-12-01

    Malt liquor (ML) is a unique, high alcohol content beverage marketed to encourage heavy drinking. We developed the Malt Liquor Expectancy Questionnaire (MLEQ), a beverage-specific measure of alcohol expectancies, and examined its association with typical weekly ML use, typical weekly alcohol use, and alcohol problems. Forty positive and 40 negative expectancy items were administered to a sample of 639 young adults who regularly consumed ML. Exploratory and confirmatory factor analyses led to the development of the 30-item MLEQ. The MLEQ consists of two positive (i.e., Social Facilitation and Enjoyment, Enhanced Sexuality) and two negative factors (i.e., Aggression and Negative Consequences; Impairment and Physical Symptoms) that possess good internal consistency, test-retest reliability, and convergent validity. The psychometrically sound MLEQ contributes to the limited research on beverage-specific expectancies and heavy drinking.

  9. High influx of carbon in walls of agglutinated foraminifers during the Permian-Triassic transition in global oceans

    USGS Publications Warehouse

    Nestell, Galina P.; Nestell, Merlynd K.; Ellwood, Brooks B.; Wardlaw, Bruce R.; Basu, Asish R.; Ghosh, Nilotpal; Phuong Lan, Luu Thi; Rowe, Harry D.; Hunt, Andrew G.; Tomkin, Jonathan H.; Ratcliffe, Kenneth T.

    2015-01-01

    The Permian–Triassic mass extinction is postulated to be related to the rapid volcanism that produced the Siberian flood basalt (Traps). Unrelated volcanic eruptions producing several episodes of ash falls synchronous with the Siberian Traps are found in South China and Australia. Such regional eruptions could have caused wildfires, burning of coal deposits, and the dispersion of coal fly ash. These eruptions introduced a major influx of carbon into the atmosphere and oceans that can be recognized in the wallstructure of foraminiferal tests present in survival populations in the boundary interval strata. Analysis of free specimens of foraminifers recovered from residues of conodont samples taken at aPermian–Triassic boundary section at Lung Cam in northern Vietnam has revealed the presence of a significant amount of elemental carbon, along with oxygen and silica, in their test wall structure, but an absence of calcium carbonate. These foraminifers, identified as Rectocornuspira kalhori, Cornuspira mahajeri, and Earlandia spp. and whose tests previously were considered to be calcareous, are confirmed to be agglutinated, and are now referred to as Ammodiscus kalhori and Hyperammina deformis. Measurement of the 207Pb/204Pb ratios in pyrite clusters attached to the foraminiferal tests confirmed that these tests inherited the Pb in their outer layer from carbon-contaminated seawater. We conclude that the source of the carbon could have been either global coal fly ash or forest fire-dispersed carbon, or a combination of both, that was dispersed into the Palaeo-Tethys Ocean immediately after the end-Permian extinction event.

  10. Test and evaluation document for DOT Specification 7A Type A packaging

    SciTech Connect

    Cruse, J.M.

    1992-06-01

    The US Department of Energy (DOE) has been conducting, through several of its operating contractors, an evaluation and testing program to qualify Type A radioactive material packagings per US Department of Transportation Specification 7A (DOT-7A) of the Code of Federal Regulations, Title 49, Part 178, Section 178.350 (49 CFR 178.350). This program is called the DOT-7A Program. The DOT-7A Program is currently administered by the DOE, Division of Quality Verification and Transportation Safety, DOE/EH-33.3, at DOE-Headquarters in Germantown, Maryland. This document presents approximately 200 different packagings that have been determined to meet the requirements for a DOT Specification 7A Type A packaging per 49 CFR 178.350. It was originally prepared in 1987 by Monsanto Research Corporation -- Mound Laboratory for the DOE`s Security Evaluation Program to facilitate the regulation changes implemented by HM-169 for all DOE contractors. In September 1989, the program was transferred to Westinghouse Hanford Company, which is located in Richland, Washington. The specific packaging data contained in this document will serve to meet the requirements of 49 CFR 173.415(a) for ``. . . documentation of tests . . . `` when the packagings are used as prescribed herein. However, shippers are cautioned that additional documentation will be needed to fulfill all of the requirements for a particular shipment. Most important is the evaluation of the contents to be shipped for compatibility with the packaging and that their characteristics are bounded by the simulated contents used in qualification testing.

  11. Rabies Group-Specific Ribonucleoprotein Antigen and a Test System for Grouping and Typing of Rhabdoviruses

    PubMed Central

    Schneider, L. G.; Dietzschold, B.; Dierks, R. E.; Matthaeus, W.; Enzmann, P.-J.; Strohmaier, K.

    1973-01-01

    Cell-associated ribonucleoprotein (RNP) was isolated from BHK-21 cells infected with several strains of rabies and rabies-related viruses. The RNP-antigen from rabies and related viruses induced the formation of complement-fixing, precipitating, and immunofluorescent antibodies, and proved to be the group-specific antigen common to all rabies viruses. Antigens of the envelope which induce virus-neutralizing antibodies are apparently determinative for the serotype of a virus as evidenced by two-way neutralization tests. A combination of these methods seems to be a useful approach to the serological grouping and typing of rhabdoviruses. Images PMID:4196634

  12. The sensitivity and specificity of a diagnostic test of sequence-space synesthesia.

    PubMed

    Rothen, Nicolas; Jünemann, Kristin; Mealor, Andy D; Burckhardt, Vera; Ward, Jamie

    2016-12-01

    People with sequence-space synesthesia (SSS) report stable visuo-spatial forms corresponding to numbers, days, and months (amongst others). This type of synesthesia has intrigued scientists for over 130 years but the lack of an agreed upon tool for assessing it has held back research on this phenomenon. The present study builds on previous tests by measuring the consistency of spatial locations that is known to discriminate controls from synesthetes. We document, for the first time, the sensitivity and specificity of such a test and suggest a diagnostic cut-off point for discriminating between the groups based on the area bounded by different placement attempts with the same item.

  13. Designing a biased specification-based subjective test of image quality

    NASA Astrophysics Data System (ADS)

    Reibman, Amy R.

    2015-03-01

    Specification-based subjective tests (SBSTs) form the basis for almost all performance analysis of image and video quality estimators (QEs). Our ability to compare the efficacy of different QEs across a wide range of applications depends on careful design of these SBST, so the conclusions that are drawn about how well a QE performs are reliable and accurate. In this paper, we explore methods to design biased SBSTs for image and video QEs. A biased SBST will produce an estimate of the performance of a given QE that is systematically different than its actual performance. We demonstrate by proof of concept that it's possible to create SBSTs that generate misleading or biased Pearson or Spearman correlation coefficients between subjective and objective scores, and we present some diagnostics that begin to evaluate when influential observations have been included in the SBST. Understanding how to create biased tests is a first step toward the overall goal of creating more effective unbiased SBSTs.

  14. Mission Control Center (MCC) System Specification for the Shuttle Orbital Flight Test (OFT) Timeframe

    NASA Technical Reports Server (NTRS)

    1976-01-01

    System specifications to be used by the mission control center (MCC) for the shuttle orbital flight test (OFT) time frame were described. The three support systems discussed are the communication interface system (CIS), the data computation complex (DCC), and the display and control system (DCS), all of which may interfere with, and share processing facilities with other applications processing supporting current MCC programs. The MCC shall provide centralized control of the space shuttle OFT from launch through orbital flight, entry, and landing until the Orbiter comes to a stop on the runway. This control shall include the functions of vehicle management in the area of hardware configuration (verification), flight planning, communication and instrumentation configuration management, trajectory, software and consumables, payloads management, flight safety, and verification of test conditions/environment.

  15. The Reliability, Validity and Applicability of Two Sport-Specific Power Tests in Synchronized Swimming

    PubMed Central

    Peric, Mia; Zenic, Natasa; Mandic, Gordana Furjan; Sekulic, Damir; Sajber, Dorica

    2012-01-01

    Sport-specific tests are rarely investigated in synchronized swimming (synchro). The aim of this research was to study the reliability and the validity of two sport-specific tests that are based on synchro elements, namely, the Barracuda thrust (“Barracuda”) and the Boost. The Barracuda is a move in which the swimmer begins in the back pike position (head down with the legs perpendicular to the surface of the water) and then moves the legs and hips rapidly upward, unrolling the body to obtain a maximal vertical position above the surface of the water. The Boost occurs when the swimmer rises rapidly out of the water, head first, to bring as much of the body as possible above the surface of the water. Both patterns are considered power moves and are therefore theoretically related to explosive strength. This study involved 22 female competitive synchro swimmers aged 16–18 years. The variables examined included performance on the Barracuda, Boost and countermovement jump and anthropometric measures (body height, body weight and body composition). Statistical analyses showed appropriate reliability for all tests, with no systematic bias between trials. A factor analysis calculated for the Barracuda, Boost and countermovement jump revealed one significant factor based on the Guttmann-Kaiser criterion with all three tests significantly projected. The structure of the significant factor did not change if the results for the Boost and Barracuda were normalized for body height. The Boost and Barracuda, but not the countermovement jump, were significantly correlated with the competitive achievements of the swimmers. In conclusion, the Boost and Barracuda are reliable and valid measures of the explosive strength of synchronized swimmers and are significantly related to competitive achievement. PMID:23487473

  16. Comparison of test specific sediment effect concentrations with marine sediment quality assessment guidelines

    SciTech Connect

    Carr, R.S.; Biedenbach, J.M.; Long, E.R.; MacDonald, D.D.

    1995-12-31

    As part of NOAA`s National Status and Trends (NS and T) Bioeffects Assessment program and studies conducted by the National Biological Service, numerous sediment quality assessment surveys have recently been conducted along the Atlantic and Gulf coasts of the US using the sea urchin (Arbacia punctulata) fertilization and embryological development tests with pore water. Additional toxicity tests were also conducted in conjunction with most of these studies. The areas that have been sampled include Boston harbor, Massachusetts; Charleston Harbor, Winyah Bay, and Savannah River, South Carolina; St. Simon Sound, Georgia; Biscayne Bay, Tampa Bay, Choctawhatchee Bay, Apalachicola Bay, St. Andrew Bay, and Pensacola Bay, Florida; Galveston Bay, Lavaca Bay, and Sabine Lake, Texas, and 200 stations in the vicinity of offshore oil and gas production platforms in the Gulf of Mexico. Sufficient data are now available from this series of surveys to calculate test specific sediment effect concentrations (SECs). Based on these recent studies, SECs were developed for the sea urchin porewater and amphipod tests and compared with existing marine sediment quality assessment guidelines.

  17. Development, validity, and reliability of a ballet-specific aerobic fitness test.

    PubMed

    Twitchett, Emily; Nevill, Alan; Angioi, Manuela; Koutedakis, Yiannis; Wyon, Matthew

    2011-09-01

    The aim of this study was to develop and assess the reliability and validity of a multi-stage, ballet-specific aerobic fitness test to be used in a dance studio setting. The test consists of five stages, each four minutes long, that increase in intensity. It uses classical ballet movement of an intermediate-level of difficulty, thus emphasizing physiological demand rather than skill. The demand of each stage was determined by calculating the mean oxygen uptake during its final minute using a portable gas analyser. After an initial familiarization period, eight female subjects performed the test twice within seven days. The results showed significant differences in oxygen consumption between stages (p < 0.001), but not between trials. Pearson correlation co-efficients produced a very good linear relationship between trials (r = 0.998, p < 0.001). Bland-Altman reliability analysis revealed the 95% limits of agreement to be ± 6.2 ml·kg(-1)·min(-1), showing good agreement between trials. The oxygen uptake in our subjects equated positively to previous estimates for class and performance, confirming validity. It was concluded that the test is suitable for use among classical ballet dancers, with many possible applications.

  18. Degradation in PV Encapsulation Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

    SciTech Connect

    Miller, David; Annigoni, Eleonora; Ballion, Amal; Bokria, Jayesh G.; Bruckman, Laura S.; Burns, David M.; Chen, Xinxin; Feng, Jiangtao; French, Roger H.; Fowler, Sean; Honeker, Christian C.; Kempe, Michael; Khonkar, Hussam; Kohl, Michael; Perret-Aebi, Laure-Emmanuelle; Phillips, Nancy H.; Scott, Kurt P.; Sculati-Meillaud, Fanny; Wohlgemuth, John

    2016-06-06

    Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

  19. Degradation in PV Encapsulant Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

    SciTech Connect

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal; Bokria, Jayesh G.; Bruckman, Laura S.; Burns, David M.; Chen, Xinxin; Feng, Jiangtao; French, Roger H.; Fowler, Sean; Honeker, Christian C.; Kempe, Michael D.; Khonkar, Hussam; Kohl, Michael; Perret-Aebi, Laure-Emmanuelle; Phillips, Nancy H.; Scott, Kurt P.; Sculati-Meillaud, Fanny; Wohlgemuth, John H.

    2016-11-21

    Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

  20. H-deficient Bombay and para-Bombay red blood cells are most strongly agglutinated by the galactophilic lectins of Aplysia and Pseudomonas aeruginosa that detect I and P1 antigens.

    PubMed

    Gilboa-Garber, N; Sudakevitz, D; Levene, C; Rahimi-Levene, N; Yahalom, V

    2006-01-01

    The galactophilic lectins Aplysia gonad lectin (AGL) and Pseudomonas aeruginosa lectin (PA-IL), which detect human I and P1 RBC antigens, were examined for hemagglutination of H+ (group O and B) and H-deficient (Bombay and para-Bombay phenotype) RBCs. The results were compared with those obtained using two other galactophilic lectins, Maclura pomifera lectin (MPL) and Arachis hypogaea (peanut) agglutinin (PNA), which share T-antigen affinity, and two fucose-binding H-specific lectins, Ulex europaeus (UEA-I) and Pseudomonas aeruginosa lectin (PA-IIL), as well as with those achieved with anti-I serum. The results revealed that, in contrast to UEA-I and PA-IIL, which preferentially agglutinated H+ RBCs, and to MPL and PNA, which similarly agglutinated all examined RBCs, AGL, PA-IL, and the anti-I serum agglutinated the H-deficient RBCs more strongly than did the H+ RBCs. These findings could be attributed to increased levels of I and P1 antigens on those RBCs resulting from the use of the free common H-type 2 precursor for their synthesis. Since both PA-IL and PA-IIL are regarded as potential pathogen adhesins, it would be interesting to statistically compare the sensitivities of individuals of H+ and H-deficient RBC populations to P. aeruginosa infections.

  1. Roche DAT immunoassay: sensitivity and specificity testing for amphetamines, cocaine, and opiates in oral fluid.

    PubMed

    Crooks, C Richard; Brown, Sue

    2010-03-01

    Laboratory testing of oral fluid for drugs of abuse continues to expand in the workplace, legal, treatment, and health settings. In this study, we assessed recently developed homogeneous Roche DAT screening assays for amphetamines, cocaine metabolite [benzoylecgonine (BZE)], methamphetamines, and opiates in oral fluid. Precision and accuracy were assessed using control samples at +/-25% of cutoff. Sensitivity, specificity, and agreement compared to liquid chromatography-tandem mass spectrometry (LC-MS-MS) was assessed by analysis of oral fluid specimens collected from 994 subjects enrolled in a drug treatment or probation and parole drug-testing program. An additional 180 research specimens from Kroll Laboratories were analyzed for amphetamine and methamphetamine. Screening cutoff concentrations (ng/mL) were as follows: amphetamines, 40; cocaine metabolite, 3; methamphetamines, 40; and opiates, 10. LC-MS-MS analyses were performed with the following cutoff concentrations (ng/mL): amphetamine, 40; BZE, 2.0; methamphetamine, 40; and codeine or morphine, 10. The percent coefficient of variation ranged from 3.4% to 7.3%. Sensitivity and specificity of the Roche DAT assays compared to LC-MS-MS were > 94%, and agreement was > 96% for the four assays. The performance of the Roche DAT assays suggests these new homogeneous screening assays will be an attractive alternative to existing more labor-intensive enzyme immunoassays.

  2. A Possible Role for Agglutinated Foraminifers in the Growth of Deep-Water Coral Bioherms

    NASA Astrophysics Data System (ADS)

    Messing, C. G.; Reed, J. K.; Brooke, S. D.

    2008-05-01

    Exploration of deep-water bioherms dominated by the scleractinian corals Lophelia pertusa and Enallopsammia profunda along the east coast of Florida in ~400-800 m depth reveals an often dense and rich assemblage of small (~1-30 mm) epifauna on dead coral branches, which is often dominated by agglutinated astrorhizacean foraminifers accompanied by thecate and athecate hydroids, sponges, stylasterids, anemones and barnacles. The dominant agglutinated foraminifer is an arborescent form up to 15 mm tall, consisting of a basal tube that gives rise to branchlets of successively decreasing diameter and thickly coated with fine-grained material including coccoliths and diatom frustules. The large numbers of foraminifers generate an enormous adhesive, sediment-trapping surface area and may represent an important accelerated route for sediment deposition and bioherm growth relative to baffling of suspended sediment particles by the coral branches themselves. These foraminifers also occur on still living coral, suggesting that they may either contribute to coral death or invade stressed colonies. They may thus be responsible for or contribute to the small percent of living corals observed in many of these habitats. Other epifauna appear to colonize after the coral has died.

  3. Ethanol induces human red cell shape transformations and enhanced ligand-mediated agglutinability

    SciTech Connect

    Weinstein, R.S.; McLawhon, R.W.; Marikovsky, Y.

    1986-03-01

    Ethanol concentrations are markedly elevated in rat stomach wall when ulcerogenic doses of 100 % ethanol (2 ml for 5 to 10 minutes) are instilled in rat gastric lumen. The authors observed that red cells in gastric mucosal postcapillary venules become spiculated and interadherent under these conditions. The authors have now studied this phenomenon in vitro using washing human red cells. Concentrations of high grade ethanol ranging from 2 to 10% (v/v) in physiological buffered saline (pH 7.3) without Ca/sup + +/ or Mg/sup + +/ at 25/sup 0/C rapidly transformed human red cells into spiculated forms. 2% ethanol transformed human red cells into disco-echinocytes in 15 min. whereas 10% ethanol transformed red blood cells into echinocytes within 3 min. Washing out of ethanol at 1 hour reverted the echinocytes into discocytes. However, following 3 hours of incubation in 10% ethanol washing out of ethanol produced stomatocytes. The ethanol-induced echinocytic shape transformations were accompanied by a dose-related increase in red cell agglutinability with poly-L-lysine or the plant lectin wheat germ agglutinin. The enhanced agglutinability was reversed by restoring the red cell shape changes and alterations in surface properties may play a role in the pathogenesis of ethanol-induced gastric ulcers.

  4. Development of a polymerase chain reaction test for specific identification of the urinary tract pathogen Aerococcus urinae.

    PubMed Central

    Aguirre, M; Collins, M D

    1993-01-01

    A polymerase chain reaction test was developed for identification of the gram-positive urinary tract pathogen Aerococcus urinae. Oligonucleotide primers were based on highly specific sequences within the small-subunit rRNA gene. A confirmatory test based on hybridization of the amplified products to a highly specific internal probe was also developed. Images PMID:7684752

  5. Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials.

    PubMed

    Lévesque, Julie; Hermawan, Hendra; Dubé, Dominique; Mantovani, Diego

    2008-03-01

    Endovascular stents have proven effective in treating coronary and peripheral arterial occlusions. Since the first attempts, metals used to make these devices have been generally selected, and designed to be highly resistant to corrosion. Therefore, as almost the totality of metallic biomaterials, they are implanted on a long-term basis. However, complications associated with permanent stents, such as in-stent restenosis and thrombosis, have often been reported. In order to reduce those complications, it would be clinically useful to develop a new family of degradable stents. An interesting material for fabrication of degradable stents is based on magnesium, an essential element involved in human metabolism. Success in using magnesium alloys for the fabrication of endovascular devices is closely related to the properties of the selected alloy. In this context, a test bench was specifically designed to reproduce the physiological conditions to which stents are submitted when implanted in the coronary arteries. Then the test bench was validated using a magnesium-based alloy. Results showed that the corrosion rate and the corrosion mechanisms vary with the applied shear stress and that corrosion products strongly depend on the composition of the corrosive solution. This test bench will thus be useful in further investigations for the development of metallic alloys as degradable biomaterials.

  6. Specifications for a coupled neutronics thermal-hydraulics SFR test case

    NASA Astrophysics Data System (ADS)

    Tassone, A.; Smirnov, A. D.; Tikhomirov, G. V.

    2017-01-01

    Coupling neutronics/thermal-hydraulics calculations for the design of nuclear reactors are a growing trend in the scientific community. This approach allows to properly represent the mutual feedbacks between the neutronic distribution and the thermal-hydraulics properties of the materials composing the reactor, details which are often lost when separate analysis are performed. In this work, a test case for a generation IV sodium-cooled fast reactor (SFR), based on the ASTRID concept developed by CEA, is proposed. Two sub-assemblies (SA) characterized by different fuel enrichment and layout are considered. Specifications for the test case are provided including geometrical data, material compositions, thermo-physical properties and coupling scheme details. Serpent and ANSYS-CFX are used as reference in the description of suitable inputs for the performing of the benchmark, but the use of other code combinations for the purpose of validation of the results is encouraged. The expected outcome of the test case are the axial distribution of volumetric power generation term (q‴), density and temperature for the fuel, the cladding and the coolant.

  7. Test and evaluation document for DOT Specification 7A type A packaging. Volume 1

    SciTech Connect

    Kelly, D L

    1997-08-04

    The US Department of Energy (DOE) has been conducting, through several of its operating contractors, an evaluation and testing program to qualify Type A radioactive material packagings per US Department of Transportation (DOT) Specification 7A (DOT-7A) of the Code of Federal Regulations (CFR), Title 49, Part 178 (49 CFR 178). This document summarizes the evaluation and testing performed for all of the packagings successfully qualified in this program. This document supersedes DOE Evaluation Document for DOT-7A Type A Packaging (Edling 1987), originally issued in 1987 by Monsanto Research Corporation Mound Laboratory (MLM), Miamisburg, Ohio, for the Department of Energy, Security Evaluation Program (I)P-4. Mound Laboratory issued four revisions to the document between November 1988 and December 1989. In September 1989, the program was transferred to Westinghouse Hanford Company (Westinghouse Hanford) in Richland, Washington. One additional revision was issued in March 1990 by Westinghouse Hanford. This revision reflects the earlier material and incorporates a number of changes. Evaluation and testing activities on 1208 three DOT-7A Program Dockets resulted in the qualification of three new packaging configurations, which are incorporated herein and summarized. This document presents approximately 300 different packagings that have been determined to meet the requirements for a DOT-7A, type A packaging per 49 CFR 178.350.

  8. Functional and structural analyses of mouse genomic regions screened by the morphological specific-locus test.

    PubMed

    Russell, L B

    1989-05-01

    Genetic analyses of certain classes of mutations recovered in the mouse specific-locus test (SLT) have characterized arrays of deletions, overlapping at the marked loci. Complementation maps, generated for several of the regions, have identified a number of functional units surrounding each marked locus and have ordered the mutations into complementation groups. Molecular entry to all but one of the marked regions has been achieved by (1) identifying proviral integrations in, or close to, the specific loci (d, se, a, c); (2) mapping random anonymous clones from appropriately enriched libraries to the longest deleted segments, then submapping to more limited segments on the basis of complementation and deletion-breakpoint maps (c, p); (3) similarly mapping known clones thought to be located in pertinent chromosomal regions (p, c, d); and (4) cloning specific genes that reside in regions corresponding to the deletions (b, c, p). The molecular analyses have confirmed that genetically-inferred deletions are structural deletions of DNA. The emerging physical maps are concordant with the complementation maps, and in several cases have discriminated among members of a complementation group with respect to breakpoint positions. Deletion-breakpoint-fusion fragments have prove to be highly useful for making large chromosomal jumps to facilitate physical mapping. The recent advances toward correlating physical and functional maps of specific regions of the mouse genome owe much to the existence of arrays of mutations involving loci marked in the SLT. In turn, the characterizations of these regions have made it possible to demonstrate qualitative differences among mutations resulting from different treatments. This new capability for qualitative analysis, which will increase as the molecular studies proceed, further enhances the value of the SLT, which has been extensively used for quantitative studies in germ-cell mutagenesis.

  9. A novel specimen-specific methodology to optimise the alignment of long bones for experimental testing.

    PubMed

    Cheong, Vee San; Bull, Anthony M J

    2015-12-16

    The choice of coordinate system and alignment of bone will affect the quantification of mechanical properties obtained during in-vitro biomechanical testing. Where these are used in predictive models, such as finite element analysis, the fidelic description of these properties is paramount. Currently in bending and torsional tests, bones are aligned on a pre-defined fixed span based on the reference system marked out. However, large inter-specimen differences have been reported. This suggests a need for the development of a specimen-specific alignment system for use in experimental work. Eleven ovine tibiae were used in this study and three-dimensional surface meshes were constructed from micro-Computed Tomography scan images. A novel, semi-automated algorithm was developed and applied to the surface meshes to align the whole bone based on its calculated principal directions. Thereafter, the code isolates the optimised location and length of each bone for experimental testing. This resulted in a lowering of the second moment of area about the chosen bending axis in the central region. More importantly, the optimisation method decreases the irregularity of the shape of the cross-sectional slices as the unbiased estimate of the population coefficient of variation of the second moment of area decreased from a range of (0.210-0.435) to (0.145-0.317) in the longitudinal direction, indicating a minimisation of the product moment, which causes eccentric loading. Thus, this methodology serves as an important pre-step to align the bone for mechanical tests or simulation work, is optimised for each specimen, ensures repeatability, and is general enough to be applied to any long bone.

  10. Assessment of Rapid Tests for Detection of Human Immunodeficiency Virus-Specific Antibodies in Recently Infected Individuals▿

    PubMed Central

    Louie, Brian; Wong, Ernest; Klausner, Jeffrey D.; Liska, Sally; Hecht, Frederick; Dowling, Terri; Obeso, Martha; Phillips, Susan S.; Pandori, Mark W.

    2008-01-01

    We have evaluated four current Food and Drug Administration-cleared rapid tests for human immunodeficiency virus (HIV)-specific antibodies with a panel of specimens from recently infected individuals. Recent infection was detected by RNA-based screening coupled with enzyme immunoassay-based testing. We found that the sensitivities of the various rapid tests vary greatly with regard to their ability to detect HIV-specific antibodies in recently infected individuals. PMID:18234875

  11. Toward a consolidation of the CPV-specific-test procedures for inverters

    NASA Astrophysics Data System (ADS)

    Voarino, Philippe; Dominguez, César; Bier, Anthony; Roujol, Yannick; Mangeant, Christophe; Baudrit, Mathieu

    2015-09-01

    The inverter in a photovoltaic system assures two essential functions. The first is to track the maximum power point of the system IV curve throughout variable environmental conditions. The second is to convert DC power delivered by the PV panels into AC power. Nowadays, in order to qualify inverters, manufacturers and certifying organisms use mainly European and/or CEC efficiency standards. The question arises if these are still representative of CPV system behaviour. We propose to use a set of CPV - specific weighted average and a representative dynamic response to have a better determination of the static and dynamic MPPT efficiencies. Four string-sized commercial inverters used in real CPV plants have been tested.

  12. Signal processing and display interface studies. [performance tests - design analysis/equipment specifications

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Signal processing equipment specifications, operating and test procedures, and systems design and engineering are described. Five subdivisions of the overall circuitry are treated: (1) the spectrum analyzer; (2) the spectrum integrator; (3) the velocity discriminator; (4) the display interface; and (5) the formatter. They function in series: (1) first in analog form to provide frequency resolution, (2) then in digital form to achieve signal to noise improvement (video integration) and frequency discrimination, and (3) finally in analog form again for the purpose of real-time display of the significant velocity data. The formatter collects binary data from various points in the processor and provides a serial output for bi-phase recording. Block diagrams are used to illustrate the system.

  13. A dedicated system for topographical working memory: evidence from domain-specific interference tests.

    PubMed

    Piccardi, L; Nori, R; Boccia, M; Barbetti, S; Verde, P; Guariglia, C; Ferlazzo, F

    2015-08-01

    In the present study, we used single- and dual-task conditions to investigate the nature of topographical working memory to better understand what type of task can hamper performance during navigation. During dual-task conditions, we considered four different sources of interference: motor (M), spatial motor (SM), verbal (i.e. articulatory suppression AS) and spatial environmental (SE). In order to assess the nature of topographical working memory, we used the Walking Corsi Test, asking the participants to perform two tasks simultaneously (M, SM, AS and SE). Our results showed that only spatial-environmental interference hampers the execution of a topographical working memory task, suggesting a task-domain-specific effect. We also found general gender differences in the topographical working memory capabilities: men were more proficient than women, regardless of the type of interferences. However, like men, women performed worse when a spatial-environmental interference was present.

  14. Identification of serum component involved in generation of neo-lectin with agglutinating and phenoloxidase activities in human serum.

    PubMed

    Manikandan, Beulaja; Ramar, Manikandan; Munusamy, Arumugam

    2014-01-01

    Human serum albumin (HSA) was identified as the component involved in generation of neo-lectin molecules with both lectin and phenoloxidase activities. Pronase treated HSA was able to agglutinate hen RBC and oxidize hydroquinone. Sodium dodecyl sulphate (SDS) treated HSA agglutinated both hen and sheep RBC as well as oxidized dopamine. The hemagglutinating activities of pronase/SDS treated HSA observed against hen RBC were dosimetric. The oxidation of pronase/SDS treated HSA with hydroquinone/dopamine, respectively, was inhibitable by inhibitors of phenoloxidase, namely, phenylthiourea and tropolone. Very low concentrations of HSA could generate these humoral neo-lectin molecules.

  15. An extremely sensitive species-specific ARMS PCR test for the presence of tiger bone DNA.

    PubMed

    Wetton, Jon H; Tsang, Carol S F; Roney, Chris A; Spriggs, Adrian C

    2002-04-18

    The survival of the tiger (Panthera tigris) is seriously threatened by poaching to provide raw materials for traditional Chinese medicines (TCMs). Most highly prized are the tiger's bones, which are used in combination with other animal and plant derivatives in pills and plasters for the treatment of rheumatism and other ailments. Hundreds of patent remedies have been produced which claim to contain tiger bone, but proof of its presence is needed if legislation prohibiting the trade in endangered species is to be enforced.A highly sensitive tiger-specific real-time PCR assay has been developed to address this problem. Using primers specific to the tiger mitochondrial cytochrome b gene, successful amplification has been reliably achieved from blood, hair and bone as well as from a range of TCMs spiked with 0.5% tiger bone. Although capable of detecting fewer than 10 substrate molecules, the seven varieties of TCM pills and plasters tested showed no detectable trace of tiger DNA before spiking. Furthermore, sequencing several "tiger bone" fragments seized from TCM shops has shown that they actually originated from cattle and pigs. The potential effects of traditional bone preparation methods, evidence that much lower concentrations are used than alleged on TCM packaging, and substitution of bones from other species all suggest a low likelihood of detecting tiger DNA in patent medicines. Despite this, the basic methods have been thoroughly proven and can be readily applied to derivatives from other Convention on International Trade in Endangered Species of Wild Fauna and Flora (CITES) protected species, providing a rapid and highly sensitive forensic test for species of origin. Potential applications to the monitoring of wild populations are demonstrated by the successful identification of shed hairs and faecal samples.

  16. Novel methylation specific real-time PCR test for the diagnosis of Klinefelter syndrome

    PubMed Central

    Mehta, Akanksha; Mielnik, Anna; Schlegel, Peter N; Paduch, Darius A

    2014-01-01

    The aim of this study was to design a molecular assay for the diagnosis of Klinefelter syndrome (KS), based on the detection of supernumerary X-chromosomes (X-chs). DNA was extracted from peripheral blood samples of twenty-six 47,XXY males; two 46,XY/47,XXY males; twenty-two 46,XY males; and 15 females; and deaminated. Methylation-specific quantitative polymerase chain reaction (MS-qPCR) was performed using primers for unmethylated and methylated copies of the X-ch inactive-specific transcript (XIST-U and XIST-M) gene. X-ch disomy was determined on the basis of XIST methylation status. Degree of mosaicism in the 46,XY/47,XXY males was compared with karyotype and fluorescent in situ hybridization (FISH) results. Data analysis was performed using the Roche® LightCycler software V. 3.5.3., including determination of crossing points (CPs) by fit-point analysis and melting curve analysis. X-ch disomy was detected in all female controls and KS patients; male controls expressed XIST-M only. CPs ranged from 29.5 to 32.5 (standard deviation (s.d.) 0.8) for XIST-U and from 29 to 31 (s.d. 0.6) for XIST-M. Limit of detection of mosaicism was 1%. Based on XIST-U/XIST-M ratios for the two 47,XXY/46,XY patients, the calculated degree of mosaicism (1.8% and 17.8%) was comparable to FISH results (2.3% and 15%, respectively). Turnaround time from DNA deamination to final data analysis was under 9 h. We conclude that MS-qPCR is a sensitive, specific and rapid test for the detection of X-ch disomy, with applicability for the screening and diagnosis of KS, even in the setting of low grade 47,XXY/46,XY mosaicism. PMID:24923458

  17. Drawing on Indigenous Criteria for More Authentic Assessment in a Specific-Purpose Language Test: Health Professionals Interacting with Patients

    ERIC Educational Resources Information Center

    Pill, John

    2016-01-01

    The "indigenous assessment practices" (Jacoby & McNamara, 1999) in selected health professions were investigated to inform a review of the scope of assessment in the speaking sub-test of a specific-purpose English language test for health professionals, the Occupational English Test (OET). The assessment criteria in current use on…

  18. Test Anxiety among College Students with Specific Reading Disability (Dyslexia): Nonverbal Ability and Working Memory as Predictors

    ERIC Educational Resources Information Center

    Nelson, Jason M.; Lindstrom, Will; Foels, Patricia A.

    2015-01-01

    Test anxiety and its correlates were examined with college students with and without specific reading disability (RD; n = 50 in each group). Results indicated that college students with RD reported higher test anxiety than did those without RD, and the magnitude of these differences was in the medium range on two test anxiety scales. Relative to…

  19. Specificity and false positive rates of the Test of Memory Malingering, Rey 15-item Test, and Rey Word Recognition Test among forensic inpatients with intellectual disabilities.

    PubMed

    Love, Christopher M; Glassmire, David M; Zanolini, Shanna Jordan; Wolf, Amanda

    2014-10-01

    This study evaluated the specificity and false positive (FP) rates of the Rey 15-Item Test (FIT), Word Recognition Test (WRT), and Test of Memory Malingering (TOMM) in a sample of 21 forensic inpatients with mild intellectual disability (ID). The FIT demonstrated an FP rate of 23.8% with the standard quantitative cutoff score. Certain qualitative error types on the FIT showed promise and had low FP rates. The WRT obtained an FP rate of 0.0% with previously reported cutoff scores. Finally, the TOMM demonstrated low FP rates of 4.8% and 0.0% on Trial 2 and the Retention Trial, respectively, when applying the standard cutoff score. FP rates are reported for a range of cutoff scores and compared with published research on individuals diagnosed with ID. Results indicated that although the quantitative variables on the FIT had unacceptably high FP rates, the TOMM and WRT had low FP rates, increasing the confidence clinicians can place in scores reflecting poor effort on these measures during ID evaluations.

  20. Degradation in PV Encapsulation Transmittance: An Interlaboratory Study Toward a Climate-Specific Test

    SciTech Connect

    Miller, David C.; Hacke, Peter L.; Kempe, Michael D.; Wohlgemuth, John H.; Annigoni, Eleonora; Sculati-Meillaud, Fanny; Ballion, Amal; Kohl, Michael; Bokria, Jayesh G.; Bruckman, Laura S.; French, Roger H.; Burns, David; Phillips, Nancy H.; Feng; Jiangtao; Elliott, Lamont; Scott, Kurt P.; Fowler, Sean; Gu, Xiaohong; Honeker, Christian C.; Khonkar, Hussam; Perret-Aebi, Laure-Emmanuelle; Shioda, Tsy

    2015-06-14

    Reduced optical transmittance of encapsulation resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of installations in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. Essential information that might be used to screen encapsulation through product lifetime remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding that will be used towards developing a climate- and configuration-specific (UV) weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens are being examined at 14 institutions using a variety of indoor chambers (including Xe, UVA-340, and metal-halide light sources) or field aging. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests. Index Terms -- reliability, durability, thermal activation.

  1. Degradation in PV Encapsulation Transmittance: An Interlaboratory Study Towards a Climate-Specific Test

    SciTech Connect

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal; Bokria, Jayesh G.; Bruckman, Laura S.; Burns, David M.; Chen, Xinxin; Elliott, L.; Feng, J.; French, Roger H.; Fowler, S.; Gu, X.; Hacke, Peter L.; Honeker, C. C.; Kempe, Michael D.; Khonkar, H.; Kohl, M.; Perret-Aebi, Laure-Emmanuelle; Phillips, N. H.; Scott, K. P.; Sculati-Meillaud, F.; Shioda, T.; Suga, S.; Watanabe, S.; Wohlgemuth, John H.

    2015-06-14

    Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of service in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. Essential information that might be used to screen encapsulation through product lifetime remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding that will be used towards developing a climate- and configuration-specific (UV) weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens are being examined at 14 institutions using a variety of indoor chambers (including Xenon, UVA-340, and metal-halide light sources) or field aging. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests.

  2. Strain-Specific Battery of Tests for Domains of Mania: Effects of Valproate, Lithium and Imipramine

    PubMed Central

    Flaisher-Grinberg, Shlomit; Einat, Haim

    2010-01-01

    The lack of efficient animal models for bipolar disorder (BPD), especially for the manic pole, is a major factor hindering the research of its pathophysiology and the development of improved drug treatments. The present study was designed to identify an appropriate mouse strain for modeling some behavioral domains of mania and to evaluate the effects of drugs using this strain. The study compared the behavior of four strains: Black Swiss, C57Bl/6, CBA/J and A/J mice in a battery of tests that included spontaneous activity; sweet solution preference; light/dark box; resident-intruder; forced-swim and amphetamine-induced hyperactivity. Based on the ‘manic-like’ behavior demonstrated by the Black Swiss strain, the study evaluated the effects of the mood stabilizers valproate and lithium and of the antidepressant imipramine in the same tests using this strain. Results indicated that lithium and valproate attenuate the ‘manic-like’ behavior of Black Swiss mice whereas imipramine had no effects. These findings suggest that Black Swiss mice might be a good choice for modeling several domains of mania and distinguishing the effects of drugs on these specific domains. However, the relevance of the behavioral phenotype of Black Swiss mice to the biology of BPD is unknown at this time and future studies will investigate molecular differences between Black Swiss mice and other strains and asess the interaction between strain and mood stabilizing treatment. PMID:21423422

  3. Degradation in PV Encapsulation Transmittance: An Interlaboratory Study Towards a Climate-Specific Test: Preprint

    SciTech Connect

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal; Bokria, Jayesh G.; Bruckman, Laura S.; Burns, David M.; Chen, Xinxin; Elliott, Lamont; Feng, Jiangtao; French, Roger H.; Fowler, Sean; Gu, Xiaohong; Hacke, Peter L.; Honeker, Christian C.; Kempe, Michael D.; Khonkar, Hussam; Kohl, Michael; Perret-Aebi, Laure-Emmanuelle; Phillips, Nancy H.; Scott, Kurt P.; Sculati-Meillaud, Fanny; Shioda, Tsuyos

    2015-08-12

    Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of service in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. Essential information that might be used to screen encapsulation through product lifetime remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding that will be used towards developing a climate- and configuration-specific (UV) weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens are being examined at 14 institutions using a variety of indoor chambers (including Xenon, UVA-340, and metal-halide light sources) or field aging. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests.

  4. Statistically tested comparisons of the accuracy of forecasting methods for age-specific and sex-specific mortality and life expectancy.

    PubMed

    Shang, Han Lin

    2015-01-01

    Although there are continuing developments in the methods for forecasting mortality, there are few comparisons of the accuracy of the forecasts. The subject of the statistical validity of these comparisons, which is essential to demographic forecasting, has all but been ignored. We introduce Friedman's test statistics to examine whether the differences in point and interval forecast accuracies are statistically significant between methods. We introduce the Nemenyi test statistic to identify which methods give results that are statistically significantly different from others. Using sex-specific and age-specific data from 20 countries, we apply these two test statistics to examine the forecast accuracy obtained from several principal component methods, which can be categorized into coherent and non-coherent forecasting methods.

  5. Quick serological detection of a cancer biomarker with an agglutinated supramolecular glycoprobe.

    PubMed

    He, Xiao-Peng; Hu, Xi-Le; Jin, Hong-Ying; Gan, Jiemin; Zhu, Huili; Li, Jia; Long, Yi-Tao; Tian, He

    2015-09-01

    While serology represents the forefront technique for cancer diagnosis, current clinical methods for the detection of serum biomarkers have flaws in terms of the need of complicated manipulations, long analytical time, and high cost. Here, we develop a supramolecular glycoprobe for the quick serological detection of a cancer biomarker. The probe formed by agglutination between self-assembled glyco-gold nanoparticles and a lectin shows subtle optical variations upon the competitive recognition of a glycoprotein biomarker secreted by cancer cells, tumor-bearing mice, as well as clinical cancer patients, with no response to a series of controls including the serum of hepatitis patients. This research provides an insight into the development of effective tools for serological diagnosis of cancer.

  6. Is HPV DNA testing specificity comparable to that of cytological testing in primary cervical cancer screening? Results of a meta-analysis of randomized controlled trials.

    PubMed

    Pileggi, Claudia; Flotta, Domenico; Bianco, Aida; Nobile, Carmelo G A; Pavia, Maria

    2014-07-01

    Human-papillomavirus (HPV) DNA testing has been proposed as an alternative to primary cervical cancer screening using cytological testing. Review of the evidence shows that available data are conflicting for some aspects. The overall goal of the study is to update the performance of HPV DNA as stand-alone testing in primary cervical cancer screening, focusing particularly on the aspects related to the specificity profile of the HPV DNA testing in respect to cytology. We performed a meta-analysis of randomized controlled clinical trials. Eight articles were included in the meta-analysis. Three outcomes have been investigated: relative detection, relative specificity, and relative positive predictive value (PPV) of HPV DNA testing versus cytology. Overall evaluation of relative detection showed a significantly higher detection of CIN2+ and CIN3+ for HPV DNA testing versus cytology. Meta-analyses that considered all age groups showed a relative specificity that favored the cytology in detecting both CIN2+ and CIN3+ lesions whereas, in the ≥30 years' group, specificity of HPV DNA and cytology tests was similar in detecting both CIN2+ and CIN3+ lesions. Results of the pooled analysis on relative PPV showed a not significantly lower PPV of HPV DNA test over cytology. A main key finding of the study is that in women aged ≥30, has been found an almost overlapping specificity between the two screening tests in detecting CIN2 and above-grade lesions. Therefore, primary screening of cervical cancer by HPV DNA testing appears to offer the right balance between maximum detection of CIN2+ and adequate specificity, if performed in the age group ≥30 years.

  7. Testing the dose-response specification in epidemiology: public health and policy consequences for lead.

    PubMed

    Rothenberg, Stephen J; Rothenberg, Jesse C

    2005-09-01

    Statistical evaluation of the dose-response function in lead epidemiology is rarely attempted. Economic evaluation of health benefits of lead reduction usually assumes a linear dose-response function, regardless of the outcome measure used. We reanalyzed a previously published study, an international pooled data set combining data from seven prospective lead studies examining contemporaneous blood lead effect on IQ (intelligence quotient) of 7-year-old children (n = 1,333). We constructed alternative linear multiple regression models with linear blood lead terms (linear-linear dose response) and natural-log-transformed blood lead terms (log-linear dose response). We tested the two lead specifications for nonlinearity in the models, compared the two lead specifications for significantly better fit to the data, and examined the effects of possible residual confounding on the functional form of the dose-response relationship. We found that a log-linear lead-IQ relationship was a significantly better fit than was a linear-linear relationship for IQ (p = 0.009), with little evidence of residual confounding of included model variables. We substituted the log-linear lead-IQ effect in a previously published health benefits model and found that the economic savings due to U.S. population lead decrease between 1976 and 1999 (from 17.1 microg/dL to 2.0 microg/dL) was 2.2 times (319 billion dollars) that calculated using a linear-linear dose-response function (149 billion dollars). The Centers for Disease Control and Prevention action limit of 10 microg/dL for children fails to protect against most damage and economic cost attributable to lead exposure.

  8. Agglutination of Histoplasma capsulatum by IgG Monoclonal Antibodies against Hsp60 Impacts Macrophage Effector Functions▿

    PubMed Central

    Guimarães, Allan Jefferson; Frases, Susana; Pontes, Bruno; de Cerqueira, Mariana Duarte; Rodrigues, Marcio L.; Viana, Nathan Bessa; Nimrichter, Leonardo; Nosanchuk, Joshua Daniel

    2011-01-01

    Histoplasma capsulatum can efficiently survive within macrophages, facilitating H. capsulatum translocation from the lung into the lymphatics and bloodstream. We have recently generated monoclonal antibodies (MAbs) to an H. capsulatum surface-expressed heat shock protein of 60 kDa (Hsp60) that modify disease in a murine histoplasmosis model. Interestingly, the MAbs induced different degrees of yeast cell agglutination in vitro. In the present study, we characterized the agglutination effects of the antibodies to Hsp60 on H. capsulatum yeast cells by light microscopy, flow cytometry, dynamic light scattering, measuring zeta potential, and using optical tweezers. We found that immunoglobulin Gs (IgGs) to Hsp60 cause H. capsulatum aggregation dependent on the (i) concentration of MAbs, (ii) MAb binding constant, and (iii) IgG subclass. Furthermore, infection of macrophages using agglutinates of various sizes after incubation with different Hsp60-binding MAbs induced association to macrophages through distinct cellular receptors and differentially affected macrophage antifungal functions. Hence, the capacity of IgG MAbs to agglutinate H. capsulatum significantly impacted pathogenic mechanisms of H. capsulatum during macrophage infection, and the effect was dependent on the antibody subclass and antigen epitope. PMID:21134968

  9. Standardization of the carbon-phenolic materials and processes. Vol. 2: Test methods and specifications

    NASA Technical Reports Server (NTRS)

    Hall, William B.

    1988-01-01

    Carbon-phenolic composite materials are used in the ablation process in the nozzles of the Space Shuttle Main Engine. The nozzle is lined with carbon cloth-phenolic resin composites. The extreme heat and erosion of the burning propellant are controlled by the carbon-phenolic composite by means of ablation, a heat and mass transfer process in which a large amount of heat is dissipated by sacrificailly removing material from a surface. Phenolic materials ablate with the initial formation of a char. The depth of the char is a function of the heat conduction coefficient of the composite. The char layer is a poor conductor so it protects the underlying phenolic composite from the high heat of the burning propellant. The nozzle component ablative liners (carbon cloth-phenolic resin composites) are tape wrapped, hydroclave and/or autoclave cured, machined and assembled. The tape consists of prepreg broadcloth. The materials flow sheet for the nozzle ablative liners is given. The prepreg is a three component system: phenolic resin, carbon cloth, and carbon filler. This is Volume 2 of the report, Test Methods and Specifications.

  10. Rare attributes in finite universe: Hypotheses testing specification and exact randomized upper confidence bounds

    SciTech Connect

    Wright, T.

    1993-03-01

    When attributes are rare and few or none are observed in the selected sample from a finite universe, sampling statisticians are increasingly being challenged to use whatever methods are available to declare with high probability or confidence that the universe is near or completely attribute-free. This is especially true when the attribute is undesirable. Approximations such as those based on normal theory are frequently inadequate with rare attributes. For simple random sampling without replacement, an appropriate probability distribution for statistical inference is the hypergeometric distribution. But even with the hypergeometric distribution, the investigator is limited from making claims of attribute-free with high confidence unless the sample size is quite large using nonrandomized techniques. In the hypergeometric setting with rare attributes, exact randomized tests of hypothesis a,re investigated to determine the effect on power of how one specifies the null hypothesis. In particular, specifying the null hypothesis as zero attributes does not always yield maximum possible power. We also consider the hypothesis specification question under complex sampling designs including stratified random sampling and two-stage cluster sampling (one case involves random selection at first stage and another case involves probability proportional to size without replacement selection at first stage). Also under simple random sampling, this article defines and presents a simple algorithm for the construction of exact randomized'' upper confidence bounds which permit one to possibly report tighter bounds than those exact bounds obtained using nonrandomized'' methods.

  11. Rare attributes in finite universe: Hypotheses testing specification and exact randomized upper confidence bounds

    SciTech Connect

    Wright, T.

    1993-03-01

    When attributes are rare and few or none are observed in the selected sample from a finite universe, sampling statisticians are increasingly being challenged to use whatever methods are available to declare with high probability or confidence that the universe is near or completely attribute-free. This is especially true when the attribute is undesirable. Approximations such as those based on normal theory are frequently inadequate with rare attributes. For simple random sampling without replacement, an appropriate probability distribution for statistical inference is the hypergeometric distribution. But even with the hypergeometric distribution, the investigator is limited from making claims of attribute-free with high confidence unless the sample size is quite large using nonrandomized techniques. In the hypergeometric setting with rare attributes, exact randomized tests of hypothesis a,re investigated to determine the effect on power of how one specifies the null hypothesis. In particular, specifying the null hypothesis as zero attributes does not always yield maximum possible power. We also consider the hypothesis specification question under complex sampling designs including stratified random sampling and two-stage cluster sampling (one case involves random selection at first stage and another case involves probability proportional to size without replacement selection at first stage). Also under simple random sampling, this article defines and presents a simple algorithm for the construction of exact ``randomized`` upper confidence bounds which permit one to possibly report tighter bounds than those exact bounds obtained using ``nonrandomized`` methods.

  12. A dipstick test combined with urine specific gravity improved the accuracy of proteinuria determination in pregnancy screening.

    PubMed

    Makihara, Natsuko; Yamasaki, Mineo; Morita, Hiroki; Yamada, Hideto

    2011-01-21

    Proteinuria screening using a semi-quantitative dipstick test of the spot urine in antenatal clinic is known to have high false-positive rates. The aim of this study was to assess availability of a dipstick test combined with the urine specific gravity for the determination of pathological proteinuria. A dipstick test was performed on 582 urine samples obtained from 283 pregnant women comprising 260 with normal blood pressure and 23 with pregnancy-induced hypertension. The urine protein (P) and creatinine (C) concentrations, specific gravity (SG), P/C ratio were determined, and compared with dipstick test results. The P concentration increased along the stepwise augmentations in dipstick test result. Frequencies of the urine samples with 0.265 or more P/C ratio were 0.7% with - dipstick test result, 0.7% with the ± result, 3.3% with the 1+ result, and 88.9% with the ≥2+ result. However, if the urine specific gravity was low, frequencies of the high P/C ratio were 5.0% with ± dipstick test result and 9.3% with the 1+ result. A dipstick test result of ≥2+ seems appropriate for a criterion of positive screening for pathological proteinuria in antenatal care. A dipstick test combined with the urine specific gravity may be useful for outpatient clinic screening.

  13. Comparison of side effects of pentagastrin test and calcium stimulation test in patients with increased basal calcitonin concentration: the gender-specific differences.

    PubMed

    Ubl, Philipp; Gincu, Tatiana; Keilani, Mohammad; Ponhold, Lothar; Crevenna, Richard; Niederle, Bruno; Hacker, Marcus; Li, Shuren

    2014-08-01

    The aim of this study was to compare the side effects of the pentagastrin test and the calcium stimulation test in patients with increased basal calcitonin concentration, especially the gender-specific differences of side effects. A total of 256 patients (123 females and 133 males, mean age of 56 ± 27 years, range 21-83 years) had both pentagastrin and calcium stimulation tests. All patients filled in a questionnaire regarding the side effects within 30 min after completion of the stimulation tests. The differences of side effects between female and male patients as well as between the pentagastrin stimulation test and the calcium stimulation test were evaluated. Warmth feeling was the most frequent occurring side effect in all patients who had both pentagastrin and calcium stimulation tests, followed by nausea, altered gustatory sensation, and dizziness. The incidences of urgency to micturate (p < 0.05) and dizziness (p < 0.05) were significantly increased in the female patients as compared to male patients by calcium stimulation test. Significant higher incidences of urgency to micturate (p < 0.05) and warmth feeling (p < 0.05) were found by calcium stimulation test as compared with those by pentagastrin test in female patients. The incidences of nausea (p < 0.05) and abdominal cramping (p < 0.05) in male patients were significantly higher by pentagastrin stimulation test than by calcium stimulation test. There is a significant gender-specific difference in side effects induced by calcium stimulation test. Female patients have fewer side effects by pentagastrin test than by calcium stimulation test. Male patients may tolerate the calcium stimulation test better than the pentagastrin test.

  14. Evaluation of three serological tests manufactured in Belarus for the diagnosis of syphilis.

    PubMed

    Shimanskaya, Iryna; Zhurauskaya, Larisa; Pankratov, Oleg; Unemo, Magnus; Ballard, Ronald C; Domeika, Marius

    2011-05-01

    The performance of three serological tests manufactured in Belarus for the diagnosis of syphilis, i.e. a microprecipitation reaction (MPR) and two enzyme-linked immunosorbent assays (ELISAs) were compared with internationally recognized assays, namely the rapid plasma reagin test and the Treponema pallidum passive particle agglutination assay (TPPA). Sera from 392 consecutive patients attending Brest (Belarus) regional dermatovenereological dispensaries were tested. The sensitivity of the MPR test was low (77.3%) compared with the rapid plasma reagin test, while the specificity was high (100%). In contrast, both Belarusian ELISAs performed well when compared with the TPPA (sensitivities of 99.2% and 100%, specificities of 98.7% and 99.0%, respectively). There is a clear need to improve the sensitivity of the existing Belarusian MPR test or to use a more sensitive screening test in order to improve diagnosis of the disease in Belarus.

  15. Unidimensional IRT Item Parameter Estimates across Equivalent Test Forms with Confounding Specifications within Dimensions

    ERIC Educational Resources Information Center

    Matlock, Ki Lynn; Turner, Ronna

    2016-01-01

    When constructing multiple test forms, the number of items and the total test difficulty are often equivalent. Not all test developers match the number of items and/or average item difficulty within subcontent areas. In this simulation study, six test forms were constructed having an equal number of items and average item difficulty overall.…

  16. Language Learner Strategies and Linguistic Competence as Factors Affecting Achievement Test Scores in English for Specific Purposes

    ERIC Educational Resources Information Center

    Jurkovic, Violeta

    2010-01-01

    The article examines the effect of two factors on achievement test scores in English as a foreign language for specific purposes in higher education: preexisting linguistic competence and frequency of use of language learner strategies. The rationale for the analysis of language learner strategies as a factor affecting achievement test outcomes is…

  17. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Test Concentration Ranges, Number of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications Pollutant Concentration...

  18. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test Concentration Ranges, Number of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications Pollutant Concentration...

  19. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Test Concentration Ranges, Number of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications Pollutant Concentration...

  20. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Test Concentration Ranges, Number of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications Pollutant Concentration...

  1. Extending the Scope of Speaking Assessment Criteria in a Specific-Purpose Language Test: Operationalizing a Health Professional Perspective

    ERIC Educational Resources Information Center

    O'Hagan, Sally; Pill, John; Zhang, Ying

    2016-01-01

    Criticism of specific-purpose language (LSP) tests is often directed at their limited ability to represent fully the demands of the target language use situation. Such criticisms extend to the criteria used to assess test performance, which may fail to capture what matters to participants in the domain of interest. This paper reports on the…

  2. Spontaneous mutations recovered as mosaics in the mouse specific-locus test.

    PubMed

    Russell, L B; Russell, W L

    1996-11-12

    The specific-locus test (SLT) detects new mutants among mice heterozygous for seven recessive visible markers. Spontaneous mutations can be manifested not only as singleton whole-body mutants in controls (for which we report new data), but as mosaics-either visible (manifesting mottled coat color) in the scored generation (G2) or masked, among the wild-type parental generation (G1). Masked G1 mosaics reveal themselves by producing clusters of whole-body mutants in G2. We provide evidence that most, if not all, mosaics detected in the SLT (both radiation and control progenies) result from a single-strand spontaneous mutation subsequent to the last premeiotic mitosis and before the first postmeiotic one of a parental genome-the "perigametic interval." Such events in the genomes of the G1 and Gzero results, respectively, in visible and masked 50:50 mosaics. Per cell cycle, the spontaneous mutation rate in the perigametic interval is much higher than that in pregamete mitotic divisions. A clearly different locus spectrum further supports the hypothesis of different origin, and casts further doubt on the validity of the doubling-dose risk-estimation method. Because mosaics cannot have arisen in mitotic germ cells, and are not induced by radiation exposure in the perigametic interval, they should not be included in calculations of radiation-induced germ-line mutation rates. For per-generation calculations, inclusion of mosaics yields a spontaneous frequency 1.7 times that calculated from singletons alone for mutations contributed by males; including both sexes, the multiple is 2.2.

  3. Association of black race with follow-up of an abnormal prostate-specific antigen test.

    PubMed

    Turner, Barbara J; Mavandadi, Shahrzad; Weiner, Mark G

    2011-02-01

    Delayed evaluation after a clearly abnormal prostate-specific antigen (PSA) result may contribute to more advanced prostate cancer at diagnosis in black men. In 46 primary care practices over a period of 4.5 years, we studied men aged more than 50 years without known prostate cancer who had a PSA of at least 10.0 ng/mL for the first time. PSA follow-up included: a urology appointment, a new prostate diagnosis, or repeat PSA test. Cox proportional hazards models assessed time to follow-up, adjusting for demographic, clinical, and health care factors with censoring at a time that represents excessive delay (200 days). Among all 724 study men (27% black), delay until PSA follow-up averaged 115.2 days (+/- 79.7 d) and the unadjusted hazard ratio (HR) for follow-up was shorter for black men than nonblack men (HR, 1.23; 95% CI, 1.00-1.51). However, black men were more likely to have had prior urology care and had higher index PSA levels than other men; both factors were associated with shorter follow-up. After adjustment, delay did not differ for black vs nonblack race (HR, 1.05; 95% Cl, 0.78-1.43) but men aged at least 75 years had a longer delay than men aged 74 years or less (HR, 0.72; 95% CI, 0.59-0.89). Despite black men having greater risk of advanced prostate disease at diagnosis and better linkage to urologic care, follow-up was delayed, on average, by more than 3 months and did not differ by race. These results reveal a potentially important, remediable factor to improve prostate cancer prevention and care for black men.

  4. The reliability and validity of a soccer-specific nonmotorised treadmill simulation (intermittent soccer performance test).

    PubMed

    Aldous, Jeffrey W F; Akubat, Ibrahim; Chrismas, Bryna C R; Watkins, Samuel L; Mauger, Alexis R; Midgley, Adrian W; Abt, Grant; Taylor, Lee

    2014-07-01

    This study investigated the reliability and validity of a novel nonmotorised treadmill (NMT)-based soccer simulation using a novel activity category called a "variable run" to quantify fatigue during high-speed running. Twelve male University soccer players completed 3 familiarization sessions and 1 peak speed assessment before completing the intermittent soccer performance test (iSPT) twice. The 2 iSPTs were separated by 6-10 days. The total distance, sprint distance, and high-speed running distance (HSD) were 8,968 ± 430 m, 980 ± 75 m and 2,122 ± 140 m, respectively. No significant difference (p > 0.05) was found between repeated trials of the iSPT for all physiological and performance variables. Reliability measures between iSPT1 and iSPT2 showed good agreement (coefficient of variation: <4.6%; intraclass correlation coefficient: >0.80). Furthermore, the variable run phase showed HSD significantly decreased (p ≤ 0.05) in the last 15 minutes (89 ± 6 m) compared with the first 15 minutes (85 ± 7 m), quantifying decrements in high-speed exercise compared with the previous literature. This study validates the iSPT as a NMT-based soccer simulation compared with the previous match-play data and is a reliable tool for assessing and monitoring physiological and performance variables in soccer players. The iSPT could be used in a number of ways including player rehabilitation, understanding the efficacy of nutritional interventions, and also the quantification of environmentally mediated decrements on soccer-specific performance.

  5. Power Supply System for the Atlas Experiment: Design Specifications, Implementation, Test and First Results

    NASA Astrophysics Data System (ADS)

    Lazzaroni, M.; Citterio, M.; Latorre, S.; Lanza, A.; Cova, P.; Delmonte, N.; Giuliani, F.

    2014-06-01

    The planned upgrade of instrumentation sensitivity in the ATLAS experiment of the Large Hadron Collider (LHC), at CERN, calls for a new type of power distribution architecture. Moreover, power supplies require DC-DC power converters able to work in very hostile environment and maintaining high level of Reliability, Availability, Maintainability and Safety (denoted as RAMS requirements) during the experimental activity. Two main issues need to be discussed: first, electronic devices and equipment must operate in very high background of both charged and neutral particles and high static magnetic field and, second, the increase of the radiation background and the requirements of new front-end electronics are indeed incompatible with the current capability of the actual distribution system. The APOLLO R&D collaboration, funded by the Italian Istituto Nazionale di Fisica Nucleare (INFN), aims to study dedicated topologies of both distribution system and DC-DC power converters and to design, build and test demonstrators, developing the needed technology for the industrialization phase. The collaboration has designed a 3kW, 280V-12V converter (MC) based on the Switch in Line architecture (SIL), a DC to DC phase-shifted converter characterized by a disposition in line of the MOSFETs with good soft switching performances, and in the last year many steps have been taken to enhance the power dissipation and the reliability and to improve the general features of the designed converter. In particular a new water heat sink was designed on the basis of TFD simulation accounting for the layout of the specific converter. Experimental activities in order to characterize both thermal and electrical features of the MC confirm the correctness of the adopted design criteria.

  6. Detection of Bovine viral diarrhea virus-specific neutralizing antibodies in fresh colostrum: a modification of the virus neutralization test.

    PubMed

    Bedekovic, Tomislav; Mihaljevic, Zeljko; Jungic, Andreja; Lemo, Nina; Lojkic, Ivana; Cvetnic, Zeljko; Cac, Zeljko

    2013-03-01

    To eliminate cytotoxic effects of colostrum on cells, a modified virus neutralization test (VNT) for the detection of Bovine viral diarrhea virus-specific neutralizing antibodies in colostrum was developed. The new test was compared to the World Organization for Animal Health-recommended VNT and the results evaluated. The agreement of the new test compared to the standard VNT was determined to be 98%, whereas sensitivity and specificity of the modified VNT compared to the standard VNT were 100%. Bovine viral diarrhea virus-specific antibodies were detected in 42 sera samples and 38 colostrum samples. The antibody titers in serum and colostrum showed a high correlation (n = 56, r = 0.9719, P < 0.001). The modified virus neutralization technique described herein succeeds in eliminating cytotoxic effects and can be readily applied for the detection of specific antibodies against other infectious agents in colostrum.

  7. The development of a test specification to determine the rollover protection of passengers in light commercial vehicles fitted with canopies.

    PubMed

    Honiball, E J; van Niekerk, J L

    2001-09-01

    In this paper, a basic test specification is proposed to assess the structural integrity of a canopy that covers the load-area of a light commercial vehicle (LCV) used to carry passengers in the rear. The proposed test specification is a first step towards improving the safety of these passengers during rollover accidents. Different test methods were evaluated for applicability, ease of use and financial implications. The mass and geometric characteristics of three different one-ton LCVs were experimentally obtained and used to determine the minimum lateral velocity that will result in a rollover should a tripping mechanism be encountered. These velocities, in conjunction with other published data, were used to determine the energy required for a pendulum qualification test. It was decided that 7.7 kJ of energy delivered by a pendulum travelling between 4 and 7 m/s just prior to impact would be the most representative load case. A finite element analysis (FEA) of the proposed impact test on a specimen canopy was completed. Thereafter, the actual pendulum impact test was conducted to demonstrate the applicability of the proposed test procedure as well as the correlation with the FEA. It was shown that both FEA and actual testing are viable qualification procedures and that they can in fact be used to reliably assess the strength of the canopy. Finally, the outline of a test specification was developed and proposed, which can be used by national regulatory institutions to assess the structural integrity of commercially manufactured canopies.

  8. Detection of specific immunoglobulin E in patients with toxoplasmosis.

    PubMed Central

    Pinon, J M; Toubas, D; Marx, C; Mougeot, G; Bonnin, A; Bonhomme, A; Villaume, M; Foudrinier, F; Lepan, H

    1990-01-01

    An immunocapture assay was developed to detect Toxoplasma gondii-specific immunoglobulin E (IgE) in sera from adults with acute acquired infection or reactivation and from babies with congenital toxoplasmosis. The components of this assay were monoclonal antibody to human IgE, samples from patients, and T. gondii tachyzoites treated with Formalin. When T. gondii-specific IgE antibodies were present, visually detectable agglutination occurred. Sera, umbilical cord blood, fetal blood, cerebrospinal fluid, and amniotic fluid were tested by this method. Specific IgE antibodies were detected in sera from 25 (86%) of 29 adults who developed specific IgG antibody during pregnancy or had specific IgA and IgM antibodies. Specific IgE was present early during infection, at the time that IgM antibodies were present, and slightly preceding the presence of specific IgA antibodies. In 23 patients tested serially, IgE antibodies never persisted for longer than 4 months. No nonspecific anti-T. gondii IgE was detected in sera from uninfected individuals. Maternal IgE antibodies did not cross the placenta. In sera of patients with congenital toxoplasmosis, specific IgE antibodies were found at birth, during the first year of life, and during immunologic recrudescence following discontinuation of pyrimethamine-sulfonamide therapy. The IgE immunocapture assay is simple to perform. It is especially useful for determining when T. gondii was acquired by recently infected pregnant women. PMID:2203811

  9. Performance specifications for health physics instrumentation: portable instrumentation for use in normal work environments. Part 2. Test results

    SciTech Connect

    Kenoyer, J.L.; Swinth, K.L.; Stoetzel, G.A.; Selby, J.M.

    1986-09-01

    The Pacific Northwest Laboratory evaluated a draft American National Standards Institute Standard N42.17 (ANSI N42.17) on performance specifications for health physics instrumentation through a project jointly funded by the US Department of Energy and the US Nuclear Regulatory Commission. The evaluation involved testing a representative cross section of instruments against criteria in the standard. This report presents results of the testing program. A brief history of the project is included in the introduction. The instrumentation tested is described in general terms (i.e., types, ranges); however, no direct relationship between the results and a specific instrument model is made in this report. Testing requirements in ANSI N42.17D4, Revision 1 (May 1985) are summarized and the methods by which the tests are performed are discussed. Brief descriptions of the testing equipment are included in the methods section of the report. More detailed information about the draft standard, testing requirements and procedures, and the test equipment is included in ''Performance Specifications for Health Physics Instrumentation - Portable Instrumentation for Use in Normal Work Environments, Part 1: Manual of Testing Procedures.'' Results of testing are given in two formats: test-by-test and instrument-by-instrument. Discussion is included on significant and interesting findings, on comparisons of results from the same type of instruments from same and different manufacturers, and on data grouped by manufacturer. Conclusions are made on the applicability and practicality of the proposed standard and on instrument performance. Changes that have been made to the proposed standard based on findings of the testing program are listed and discussed. 22 refs., 11 figs., 77 tabs.

  10. Walking tests during the exercise training: specific use for the cardiac rehabilitation.

    PubMed

    Casillas, J-M; Hannequin, A; Besson, D; Benaïm, S; Krawcow, C; Laurent, Y; Gremeaux, V

    2013-10-01

    Walk tests, principally the six-minute walk test (6mWT), constitute a safe, useful submaximal tool for exercise tolerance testing in cardiac rehabilitation (CR). The 6mWT result reflects functional status, walking autonomy and efficacy of CR on walking endurance, which is more pronounced in patients with low functional capacity (heart failure - cardiac surgery). The 6mWT result is a strong predictor of mortality. However, clinically significant changes and reliability are still subject to debate - probably because of the ambiguity in terms of the target speed (either comfortable or brisk walking). Of the other time-based walk tests, the 2-minute-walk test is the only one applicable during CR, reserved for patients with severe disabilities by its psychometric properties. Fixed-distance tests (principally the 200m fast walk test) and incremental shuttle walking, tests explore higher levels of effort and may represent a safe and inexpensive alternative to laboratory-based tests during CR. These walking tests may be useful for personalizing prescription of training programs. However, the minimum clinically significant difference has not yet been determined. Lastly, walking tests appear to be potential useful tools in promoting physical activity and behavioural changes at home. Thus, validation of other walk tests with better psychometric properties will be necessary.

  11. 49 CFR 180.509 - Requirements for inspection and test of specification tank cars.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... tank car that successfully passes a periodic inspection and test must be marked as prescribed in § 180... regard to any other periodic inspection and test requirements, a tank car must have an appropriate... periodic inspection interval, test technique, and acceptance criteria for the lining or coating. The...

  12. Factors Influencing the Selection of Standardized Tests for the Diagnosis of Specific Language Impairment

    ERIC Educational Resources Information Center

    Betz, Stacy K.; Eickhoff, Jessica R.; Sullivan, Shanleigh F.

    2013-01-01

    Purpose: Standardized tests are one of the primary assessment tools used by speech-language pathologists (SLPs) to diagnose child language impairment. Numerous child language tests are commercially available; however, it is unknown what factors lead clinicians to select particular tests to use in clinical practice. This study investigated whether…

  13. 40 CFR Appendix A to Part 75 - Specifications and Test Procedures

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... temperature is above the dew-point temperature. If the cause of failure to meet the relative accuracy tests is... Coal and Coke Using High-Temperature Tube Furnace Combustion Methods; ASTM D4294-98, Standard Test... Spectrometry; ASTM D1552-01, Standard Test Method for Sulfur in Petroleum Products (High-Temperature...

  14. Block 4 solar cell module design and test specification for intermediate load center applications

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Requirements for performance of terrestrial solar cell modules intended for use in various test applications are established. During the 1979-80 time period, such applications are expected to be in the 20 to 500 kilowatt size range. A series of characterization and qualification tests necessary to certify the module design for production, and the necessary performance test for acceptance of modules are specified.

  15. THE SPECIFICITY OF THE SABIN-FELDMAN DYE TEST WITH REFERENCE TO PROTOZOAL INFECTIONS

    PubMed Central

    Kulasiri, C.

    1960-01-01

    Infections of Eimeria stiedae in normal and splenectomized rabbits and of Leishmania enriettii in normal rabbits and guinea-pigs and in splenectomized rabbits did not produce dye test antibodies. Guinea-pigs injected with Atoxoplasma sp. and rabbits immunized with cultures of Crithidia fasciculata were found to be negative for dye test antibodies. Mice which had been infected with Trypanosoma cruzi did not show dye test antibodies. All these animals, except one guinea-pig infected with Leishmania enriettii, were negative in the complement-fixation test for toxoplasmosis using the egg antigen. These findings are discussed in the light of previous reports. PMID:14412642

  16. The specificity of the Sabin-Feldman dye test with reference to protozoal infections.

    PubMed

    KULASIRI, C

    1960-07-01

    Infections of Eimeria stiedae in normal and splenectomized rabbits and of Leishmania enriettii in normal rabbits and guinea-pigs and in splenectomized rabbits did not produce dye test antibodies. Guinea-pigs injected with Atoxoplasma sp. and rabbits immunized with cultures of Crithidia fasciculata were found to be negative for dye test antibodies. Mice which had been infected with Trypanosoma cruzi did not show dye test antibodies. All these animals, except one guinea-pig infected with Leishmania enriettii, were negative in the complement-fixation test for toxoplasmosis using the egg antigen. These findings are discussed in the light of previous reports.

  17. Failings of trauma-specific and related psychological tests in detecting post-traumatic stress disorder in forensic settings.

    PubMed

    Kleinman, Stuart B; Martell, Daniel

    2015-01-01

    Judges and juries tend to be particularly impressed by test data, especially quantitative test data. Psychometric tests specific for assessing the presence of post-traumatic stress disorder (PTSD) are commonly employed by forensic mental health evaluators. Most of these instruments, however, have been designed to detect PTSD in treatment or research, and not forensic, settings. Those who rely on these measures without adequate awareness of their often significant limits in correctly identifying malingering may induce finders of fact to inordinately confidently accept the presence of PTSD. This article reviews problematic structural and content components of trauma-specific and related instruments used to evaluate PTSD and discusses the utility of specific techniques liable to be used in forensic settings to "fool" these measures.

  18. [Selected clinical and laboratory tests during specific immunotherapy of patients hypersensitive to insect bites].

    PubMed

    Szymański, W; Kazberuk, M; Michalska, I; Chyrek-Borowska, S

    The study aimed at determining selected immunologic parameters of the cellular histamine secretion and skin reactivity in the group of 9 patients hypersensitive to insect poison with effective immunotherapy following 2 years of maintenance treatment. It has been shown that the continuation of the specific immunotherapy for 2 years maintains and even increases favourable changes in humoral and cellular immunity induced already in the early phase of desensitization. An assay of the specific IgE and IgG4, cellular histamine secretion, and skin reactivity is of value in monitoring specific allergy to insect poison immunotherapy.

  19. Applicability of bacterial endotoxins test to various blood products by the use of endotoxin-specific lysates.

    PubMed

    Ochiai, Masaki; Yamamoto, Akihiko; Naito, Seishiro; Maeyama, Jun-Ichi; Masumi, Atsuko; Hamaguchi, Isao; Horiuchi, Yoshinobu; Yamaguchi, Kazunari

    2010-11-01

    Endotoxin contamination is a serious threat to the safety of parenteral drugs, and the rabbit pyrogen test has played a crucial role in controlling this contamination. Although the highly sensitive endotoxin test has replaced the pyrogen test for various pharmaceuticals, the pyrogen test is still implemented as the control test for most blood products in Japan. We examined the applicability of the endotoxin test to blood products for reliable detection and quantification of endotoxin. Nineteen types of blood products were tested for interfering factors based on spike/recovery of endotoxin by using 2 types of endotoxin-specific lysate reagents for photometric techniques. Interfering effects on the endotoxin test by the products could be eliminated by diluting from 1/2 to 1/16, with the exception of antithrombin III. However, conventional lysate reagents that also react with non-pyrogenic substances, such as (1-3)-β-D-glucan, produced results that were not relevant to endotoxin content or pyrogenicity. Our results showed that the endotoxin test would be applicable to most blood products if used with appropriate endotoxin-specific lysate reagents.

  20. Specific Effects of Test Anxiety on Reading Comprehension as Measured by the Cloze Procedure.

    ERIC Educational Resources Information Center

    Holmes, Charles Curtis

    This study was designed to determine the effects of test anxiety level and defensiveness (lie scale) level on reading comprehension of fourth grade boys as measured by the cloze procedure. The subjects, 253 male fourth graders, were administered Sarason's Test Anxiety Scale for Children and the lie scale of the General Anxiety Scale for Children.…

  1. The Measurement of Mental Retardation by a Culture-Specific Test

    ERIC Educational Resources Information Center

    Long, Peggie A.; Anthony, John J.

    1974-01-01

    This study determines whether Black students who have been placed in an EMR program on the basis of WISC full scale IQ scores as the primary criterion measure would be ruled out when tested on the BITCH. Results indicate that students obtain similar scores on both tests. (Author)

  2. Are Multiple Choice Tests Fair to Medical Students with Specific Learning Disabilities?

    ERIC Educational Resources Information Center

    Ricketts, Chris; Brice, Julie; Coombes, Lee

    2010-01-01

    The purpose of multiple choice tests of medical knowledge is to estimate as accurately as possible a candidate's level of knowledge. However, concern is sometimes expressed that multiple choice tests may also discriminate in undesirable and irrelevant ways, such as between minority ethnic groups or by sex of candidates. There is little literature…

  3. Analyzing Student Performance in Specific Subject Area Indicators on the ETS Major Field Test in Business

    ERIC Educational Resources Information Center

    Settlage, Daniel Murray; Wollscheid, Jim R.

    2015-01-01

    The Major Field Test is a commonly used assessment instrument, but little emphasis has been put on analyzing student-level subject area indicator scores. The Educational Testing Service recently made these data available to institutions, and it is analyzed here. This analysis builds on previous work by incorporating demographic and programmatic…

  4. Project A: Specification of the Predictor Domain and Development of New Selection/Classification Tests.

    ERIC Educational Resources Information Center

    Peterson, Norman G.; And Others

    1990-01-01

    Describes characteristics of experimental predictor battery of tests developed to supplement the Armed Forces Vocational Aptitude Battery for making selection and classification decisions for entry-level enlisted personnel. Explains procedures used to develop new test battery. Basic psychometric properties of each measure, as determine by large…

  5. Development of a grinding-specific performance test set-up.

    PubMed

    Olesen, C G; Larsen, B H; Andresen, E L; de Zee, M

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding performance.

  6. Cytotoxic, cell agglutinating, and syncytium forming effect of purified lectins from Ricinus communis on cultured cells.

    PubMed

    Koga, M; Ohtsu, M; Funatsu, G

    1979-10-01

    The toxicity of lectins from castor bean (Ricinus communis L.), ricin-D, ricin-E, and castor bean hemagglutinin, was investigated on five cultured cell lines. The differential effect of their constituent polypeptide chains was also investigated using these cell lines. Ricin-D, ricin-E, and castor bean hemagglutinin (CBH) possessed cytoagglutinating activity and cytotoxic activity to all five cell lines. These lectins showed the strongest toxicity to L5178Y cells, which are leukemic cells. The toxic activity of ricin-D was stronger than that of CBH in all cell lines. The constituent polypebtide chains of ricin-D and CBH were separated by DEAE-cellulose chromatography and designated as isoleucine chain and alanine chain denoted by their N-terminal amino acids. Only alanine chain of ricin-D was toxic to cells grown in vitro, whereas isoleucine chain of ricin-D and alanine chain of CBH were not toxic to the cells. Moreover, it was found that both lectins caused syncytium formation in NIH3T3 cells infected with Moloney leukemia virus and this cell fusion activity was shown to be exclusively associated with the alanine chain. Cytotoxic, cell agglutinating, and syncytium forming effect of the lectins is due to binding of the alanine chain of ricin-D to galactose-like residues of the membrane constituents of these cells.

  7. Impact of test sensitivity and specificity on pig producer incentives to control Mycobacterium avium infections in finishing pigs.

    PubMed

    van Wagenberg, Coen P A; Backus, Gé B C; Wisselink, Henk J; van der Vorst, Jack G A J; Urlings, Bert A P

    2013-09-01

    In this paper we analyze the impact of the sensitivity and specificity of a Mycobacterium avium (Ma) test on pig producer incentives to control Ma in finishing pigs. A possible Ma control system which includes a serodiagnostic test and a penalty on finishing pigs in herds detected with Ma infection was modelled. Using a dynamic optimization model and a grid search of deliveries of herds from pig producers to slaughterhouse, optimal control measures for pig producers and optimal penalty values for deliveries with increased Ma risk were identified for different sensitivity and specificity values. Results showed that higher sensitivity and lower specificity induced use of more intense control measures and resulted in higher pig producer costs and lower Ma seroprevalence. The minimal penalty value needed to comply with a threshold for Ma seroprevalence in finishing pigs at slaughter was lower at higher sensitivity and lower specificity. With imperfect specificity a larger sample size decreased pig producer incentives to control Ma seroprevalence, because the higher number of false positives resulted in an increased probability of rejecting a batch of finishing pigs irrespective of whether the pig producer applied control measures. We conclude that test sensitivity and specificity must be considered in incentive system design to induce pig producers to control Ma in finishing pigs with minimum negative effects.

  8. Type 2B von Willebrand disease associated with the release of platelet agglutinates from megakaryocytes in the bone marrow.

    PubMed

    Slayton, William B; Patel, Milin; Sola-Visner, Martha; Harris, Neil; Rivers, Angela; Montgomery, Robert R; Friedman, Kenneth D

    2008-09-01

    We report a child with thrombocytopenia since birth, circulating platelet agglutinates, and a tendency to bleed. A bone marrow aspirate revealed large platelet clumps within the bone marrow and megakaryocyte nuclei surrounded by halos of clumped platelets. Laboratory evaluation revealed type 2B von Willebrand disease. Gene sequencing revealed a G to C mutation at base 3923 of the VWF gene. This mutation was previously described in a family with circulating platelet clumps and abnormal megakaryopoiesis with release of clumped platelets in culture. This same mutation was previously described in a family with circulating platelet aggregates and abnormalities of platelet release from megakaryocytes in vitro. Presence of megakaryocytes with halos of clumped platelets in our patient suggests that platelet agglutinate occurs in the bone marrow in some type 2B von Willebrand disease patients.

  9. An acousto-optical method for registration of erythrocytes' agglutination reaction—sera color influence on the resolving power

    NASA Astrophysics Data System (ADS)

    Doubrovski, V. A.; Medvedeva, M. F.; Torbin, S. O.

    2016-01-01

    The absorption spectra of agglutinating sera were used to determine blood groups. It was shown experimentally that the sera color significantly affects the resolving power of the acousto-optical method of blood typing. In order to increase the resolving power of the method and produce an invariance of the method for sera color, we suggested introducing a probing light beam individually for different sera. The proposed technique not only improves the resolving power of the method, but also reduces the risk of false interpretation of the experimental results and, hence, error in determining the blood group of the sample. The latter is especially important for the typing of blood samples with weak agglutination of erythrocytes. This study can be used in the development of an instrument for instrumental human blood group typing based on the acousto-optical method.

  10. Application specific Tester-On-a-Resident-Chip (TORCH{trademark}) - innovation in the area of semiconductor testing

    SciTech Connect

    Bowles, M.; Peterson, T.; Savignon, D.; Campbell, D.

    1997-12-01

    Manufacturers widely recognize testing as a major factor in the cost, producability, and delivery of product in the $100 billion integrated circuit business: {open_quotes}The rapid development of VLSI using sub-micron CMOS technology has suddenly exposed traditional test techniques as a major cost factor that could restrict the development of VLSI devices exceeding 512 pins an operating frequencies above 200 MHz.{close_quotes} -- 1994 Semiconductor Industry Association Roadmap, Design and Test, Summary, pg. 43. This problem increases dramatically for stockpile electronics, where small production quantities make it difficult to amortize the cost of increasingly expensive testers. Application of multiple ICs in Multi-Chip Modules (MCM) greatly multiplies testing problems for commercial and defense users alike. By traditional test methods, each new design requires custom test hardware and software and often dedicated testing equipment costing millions of dollars. Also, physical properties of traditional test systems often dedicated testing equipment costing millions of dollars. Also, physical properties of traditional test systems limit capabilities in testing at-speed (>200 MHz), high-impedance, and high-accuracy analog signals. This project proposed a revolutionary approach to these problems: replace the multi-million dollar external test system with an inexpensive test system integrated onto the product wafer. Such a methodology enables testing functions otherwise unachievable by conventional means, particularly in the areas of high-frequency, at-speed testing, high impedance analog circuits, and known good die assessment. The techniques apply specifically to low volume applications, typical of Defense Programs, where testing costs represent an unusually high proportional of product costs, not easily amortized.

  11. Diagnostic performance of serological tests for swine brucellosis in the presence of false positive serological reactions.

    PubMed

    Dieste-Pérez, L; Blasco, J M; de Miguel, M J; Moriyón, I; Muñoz, P M

    2015-04-01

    Swine brucellosis caused by Brucella suis biovar 2 is an emerging disease in Europe. Currently used diagnostic tests for swine brucellosis detect antibodies to the O-polysaccharide (O-PS) of Brucella smooth lipopolysaccharide (S-LPS) but their specificity is compromised by false-positive serological reactions (FPSRs) when bacteria carrying cross-reacting O-PS infect pigs. FPSRs occur throughout Europe, and the only tool available for a specific B. suis diagnosis is the intradermal test with Brucella protein extracts free of O-PS or S-LPS. Using sera of 162 sows naturally infected by B. suis biovar 2, 406 brucellosis-free sows, and 218 pigs of brucellosis-free farms affected by FPSR, we assessed the diagnostic performance of an indirect ELISA with rough LPS (thus devoid of O-PS) and of gel immunodiffusion, counterimmunoelectrophoresis, latex agglutination and indirect ELISA with O-PS free proteins in comparison with several S-LPS tests (Rose Bengal, complement fixation, gel immunodiffusion and indirect ELISA). When adjusted to 100% specificity, the sensitivity of the rough LPS ELISA was very low (30%), and adoption of other cut-offs resulted in poor specificity/sensitivity ratios. Although their specificity was 100%, the sensitivity of protein tests (ELISA, latex agglutination, counterimmunoelectrophoresis, and gel immunodiffusion) was only moderate (45, 58, 61 and 63%, respectively). Among S-LPS tests, gel immunodiffusion was the only test showing acceptable sensitivity/specificity (68 and 100%, respectively). Despite these shortcomings, and when the purpose is to screen out FPSR at herd level, gel immunodiffusion tests may offer a technically simple and practical alternative to intradermal testing.

  12. Informed consent in direct-to-consumer personal genome testing: the outline of a model between specific and generic consent.

    PubMed

    Bunnik, Eline M; Janssens, A Cecile J W; Schermer, Maartje H N

    2014-09-01

    Broad genome-wide testing is increasingly finding its way to the public through the online direct-to-consumer marketing of so-called personal genome tests. Personal genome tests estimate genetic susceptibilities to multiple diseases and other phenotypic traits simultaneously. Providers commonly make use of Terms of Service agreements rather than informed consent procedures. However, to protect consumers from the potential physical, psychological and social harms associated with personal genome testing and to promote autonomous decision-making with regard to the testing offer, we argue that current practices of information provision are insufficient and that there is a place--and a need--for informed consent in personal genome testing, also when it is offered commercially. The increasing quantity, complexity and diversity of most testing offers, however, pose challenges for information provision and informed consent. Both specific and generic models for informed consent fail to meet its moral aims when applied to personal genome testing. Consumers should be enabled to know the limitations, risks and implications of personal genome testing and should be given control over the genetic information they do or do not wish to obtain. We present the outline of a new model for informed consent which can meet both the norm of providing sufficient information and the norm of providing understandable information. The model can be used for personal genome testing, but will also be applicable to other, future forms of broad genetic testing or screening in commercial and clinical settings.

  13. Spectral dependence of resolving power of optical method of detection of ultrasonically enhanced agglutination of human blood erythrocytes

    NASA Astrophysics Data System (ADS)

    Doubrovski, V. A.; Dvoretski, K. N.; Dolmashkin, A. A.

    2010-08-01

    The spectral dependence of the resolving power of an acoustooptic method of monitoring agglutination of human blood erythrocytes is studied theoretically and experimentally. It is shown that, in principle, the resolving power of this method can be increased by several dozen times. The results of the work can be used to create instruments for determining the human blood type in the AB0 system and in the Rhesus system.

  14. A technique for detection of agglutinating activity of antilymphocytic serum using formalinized and trypan-blue-stained lymphocytes

    PubMed Central

    Janković, B. D.; Isaković, Katarina; Petrović, Spomenka

    1970-01-01

    This paper describes technical details of a micro-reaction for the in vitro detection of agglutinating potency of antilymphocytic serum produced in rabbits with chicken, rat and dog thymus cells. The titration of antilymphocytic serum includes the use of microtitre plastic plates and lymphocytes treated with formalin and stained with trypan blue stain. Formalinized and stained lymphocytes represent a stable antigen of long durability, and the application of those cells in leucoagglutination increases the accuracy and sensitivity of the reaction. PMID:5477930

  15. Computer system requirements specification for 101-SY hydrogen mitigation test project data acquisition and control system (DACS-1)

    SciTech Connect

    McNeece, S.G.; Truitt, R.W.

    1994-10-12

    The system requirements specification for SY-101 hydrogen mitigation test project (HMTP) data acquisition and control system (DACS-1) documents the system requirements for the DACS-1 project. The purpose of the DACS is to provide data acquisition and control capabilities for the hydrogen mitigation testing of Tank SY-101. Mitigation testing uses a pump immersed in the waste, directed at varying angles and operated at different speeds and time durations. Tank and supporting instrumentation is brought into the DACS to monitor the status of the tank and to provide information on the effectiveness of the mitigation test. Instrumentation is also provided for closed loop control of the pump operation. DACS is also capable for being expanded to control and monitor other mitigation testing. The intended audience for the computer system requirements specification includes the SY-101 hydrogen mitigation test data acquisition and control system designers: analysts, programmers, instrument engineers, operators, maintainers. It is intended for the data users: tank farm operations, mitigation test engineers, the Test Review Group (TRG), data management support staff, data analysis, Hanford data stewards, and external reviewers.

  16. Comparison of optomagnetic and AC susceptibility readouts in a magnetic nanoparticle agglutination assay for detection of C-reactive protein.

    PubMed

    Fock, Jeppe; Parmvi, Mattias; Strömberg, Mattias; Svedlindh, Peter; Donolato, Marco; Hansen, Mikkel Fougt

    2017-02-15

    There is an increasing need to develop biosensor methods that are highly sensitive and that can be combined with low-cost consumables. The use of magnetic nanoparticles (MNPs) is attractive because their detection is compatible with low-cost disposables and because application of a magnetic field can be used to accelerate assay kinetics. We present the first study and comparison of the performance of magnetic susceptibility measurements and a newly proposed optomagnetic method. For the comparison we use the C-reactive protein (CRP) induced agglutination of identical samples of 100nm MNPs conjugated with CRP antibodies. Both methods detect agglutination as a shift to lower frequencies in measurements of the dynamics in response to an applied oscillating magnetic field. The magnetic susceptibility method probes the magnetic response whereas the optomagnetic technique probes the modulation of laser light transmitted through the sample. The two techniques provided highly correlated results upon agglutination when they measure the decrease of the signal from the individual MNPs (turn-off detection strategy), whereas the techniques provided different results, strongly depending on the read-out frequency, when detecting the signal due to MNP agglomerates (turn-on detection strategy). These observations are considered to be caused by differences in the volume-dependence of the magnetic and optical signals from agglomerates. The highest signal from agglomerates was found in the optomagnetic signal at low frequencies.

  17. EGFR mutation specific immunohistochemistry is a useful adjunct which helps to identify false negative mutation testing in lung cancer.

    PubMed

    Houang, Michelle; Sioson, Loretta; Clarkson, Adele; Watson, Nicole; Farzin, Mahtab; Toon, Christopher W; Raut, Aditi; O'Toole, Sandra A; Cooper, Wendy A; Pavlakis, Nick; Mead, Scott; Chou, Angela; Gill, Anthony J

    2014-10-01

    Mutations in EGFR guide treatment in non-small cell lung cancer (NSCLC). The most common mutations, exon 19 (delE746-A750) and exon 21 (L858R), can be identified by mutation specific immunohistochemistry (IHC). We present our prospective experience of universal reflex IHC and molecular testing in non-squamous NSCLC in the routine clinical setting.A total of 411 specimens from 332 patients were encountered over two years. Of these, 326 (98%) patients underwent EGFR IHC, 15 (5%) were positive for exon 19 deletions and 27 (8%) for exon 21 (L858R); 244 (73%) patients underwent molecular testing. Seventy-six mutations in 64 patients (19% of all patients encountered; 26% with sufficient material for testing) were identified. These comprised nine exon 18 (G719X) mutations, three also with exon 20 mutations; 24 exon 19 deletions, six also with exon 20 mutations; 23 exon 21 (L858R), three also with exon 20 mutations; and 8 exon 20 alone.All 15 exon 19 IHC positive patients were proven mutated (100% specificity, 63% sensitivity). Twenty-two of 27 exon 21 IHC positive cases were proven mutated while three patients had insufficient material for molecular testing (92% specificity, 96% sensitivity). The overall specificity and sensitivity of IHC for any EGFR mutation was 95% and 58%. Five patients initially thought to be wild type for EGFR but IHC positive underwent repeat molecular testing because of the discrepancy which confirmed the IHC result in three cases (60%).We conclude IHC is very specific but not sensitive. Whilst IHC cannot replace molecular testing, it is a useful adjunct which requires minimal tissue and identifies false negative molecular results which occurred in 5% of our patients with eventually confirmed EGFR mutations.

  18. 9 CFR 145.14 - Testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...-typhoid shall be the standard tube agglutination test, the microagglutination test, the enzyme-linked... microtest antigens and enzyme-linked immunosorbent assay reagents shall also be approved by the Department... evaluated for pullorum-typhoid as follows: (i) Serum samples that react on rapid serum test or...

  19. 9 CFR 145.14 - Testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...-typhoid shall be the standard tube agglutination test, the microagglutination test, the enzyme-linked... microtest antigens and enzyme-linked immunosorbent assay reagents shall also be approved by the Department... evaluated for pullorum-typhoid as follows: (i) Serum samples that react on rapid serum test or...

  20. The Engineering and Science Issues Test (ESIT): a discipline-specific approach to assessing moral judgment.

    PubMed

    Borenstein, Jason; Drake, Matthew J; Kirkman, Robert; Swann, Julie L

    2010-06-01

    To assess ethics pedagogy in science and engineering, we developed a new tool called the Engineering and Science Issues Test (ESIT). ESIT measures moral judgment in a manner similar to the Defining Issues Test, second edition, but is built around technical dilemmas in science and engineering. We used a quasi-experimental approach with pre- and post-tests, and we compared the results to those of a control group with no overt ethics instruction. Our findings are that several (but not all) stand-alone classes showed a significant improvement compared to the control group when the metric includes multiple stages of moral development. We also found that the written test had a higher response rate and sensitivity to pedagogy than the electronic version. We do not find significant differences on pre-test scores with respect to age, education level, gender or political leanings, but we do on whether subjects were native English speakers. We did not find significant differences on pre-test scores based on whether subjects had previous ethics instruction; this could suggest a lack of a long-term effect from the instruction.

  1. Application of a spectrally filtered probing light beam and RGB decomposition of microphotographs for flow registration of ultrasonically enhanced agglutination of erythrocytes

    NASA Astrophysics Data System (ADS)

    Doubrovski, V. A.; Ganilova, Yu. A.; Zabenkov, I. V.

    2013-08-01

    We propose a development of the flow microscopy method to increase the resolving power upon registration of erythrocyte agglutination. We experimentally show that the action of a ultrasonic standing wave on an agglutinating mixture blood-serum leads to the formation of so large erythrocytic immune complexes that it seems possible to propose a new two-wave optical method of registration of the process of erythrocyte agglutination using the RGB decomposition of microphotographs of the flow of the mixture under study. This approach increases the reliability of registration of erythrocyte agglutination and, consequently, increases the reliability of blood typing. Our results can be used in the development of instruments for automatic human blood typing.

  2. Evaluation of the single-pass flow-through test to support a low-activity waste specification

    SciTech Connect

    McGrail, B.P.; Peeler, D.K.

    1995-09-01

    A series of single-pass flow-through (SPFT) tests was performed on five reference low-activity waste glasses and a reference glass from the National Institute of Standards and Technology to support a product specification for low-activity waste (LAW) forms. The results showed that the SPFT test provides a means to quantitatively distinguish among LAW glass forms in terms of their forward reaction rate at a given temperature and solution pH. Two of the test glasses were also subjected to SPFT testing at Argonne National Laboratory (ANL). Forward reaction rate constants calculated from the ANL test data were 100 to over 1,000 times larger than the values obtained from the SPFT tests conducted at PNL. An analysis of the ANL results showed that they were inconsistent with independent measurements done on glasses of similar composition, the known pH-dependence of the forward rate, and with the results from low surface-area-to-volume, short duration product consistency tests. Because the data set obtained from the SPFT tests done at PNL was consistent with each of these same factors, a detailed examination of the test procedures used at both laboratories was performed to determine the cause(s) of the discrepancy. The omission of background subtraction in the data analysis procedure and the short-duration (on the order of hours) of the ANL tests are factors that may have significantly affected the calculated rates.

  3. Comparison of four commercially available avidity tests for Toxoplasma gondii-specific IgG antibodies.

    PubMed

    Villard, O; Breit, L; Cimon, B; Franck, J; Fricker-Hidalgo, H; Godineau, N; Houze, S; Paris, L; Pelloux, H; Villena, I; Candolfi, E

    2013-02-01

    Toxoplasma infection in pregnant women may cause congenital toxoplasmosis. Diagnosis of infection is based on serological tests aimed at detecting IgM and IgG antibodies against Toxoplasma gondii. However, IgM antibodies are not an accurate marker for discriminating between acute and latent infection. Detection of residual or persistent IgM may occur months or even years after primary infection, while the IgG avidity test is a rapid means of identifying latent infections in pregnant women who exhibit both IgG and IgM anti-Toxoplasma antibodies on initial testing during pregnancy. In this study, we assessed and compared the performances of four commercially available Toxoplasma IgG avidity tests in immunocompetent and immunocompromised patients with acute and latent toxoplasmosis. The positive predictive value of high avidity to confirm latent toxoplasmosis was 100% for all the assays, indicating that high avidity is a hallmark of latent infection. However, the negative predictive value of high avidity ranged from 99.2% (bioMérieux) to 95.3% (Abbott), indicating that acute toxoplasmosis could not be reliably diagnosed based on low IgG avidity alone. Thus, the avidity test provides a rapid means for identifying latent Toxoplasma infection in immunocompetent pregnant women presenting both IgG and IgM anti-Toxoplasma antibodies on initial testing. In terms of cost-effectiveness, avidity testing is a powerful tool that optimizes screening and follow-up of pregnant women while minimizing the costs of screening by avoiding subsequent costly maternal and fetal investigation and unnecessary treatment. The cheapest assay, Vidas Toxo IgG Avidity, also had the best performance for the diagnosis of latent toxoplasmosis.

  4. Comparison of Four Commercially Available Avidity Tests for Toxoplasma gondii-Specific IgG Antibodies

    PubMed Central

    Breit, L.; Cimon, B.; Franck, J.; Fricker-Hidalgo, H.; Godineau, N.; Houze, S.; Paris, L.; Pelloux, H.; Villena, I.

    2013-01-01

    Toxoplasma infection in pregnant women may cause congenital toxoplasmosis. Diagnosis of infection is based on serological tests aimed at detecting IgM and IgG antibodies against Toxoplasma gondii. However, IgM antibodies are not an accurate marker for discriminating between acute and latent infection. Detection of residual or persistent IgM may occur months or even years after primary infection, while the IgG avidity test is a rapid means of identifying latent infections in pregnant women who exhibit both IgG and IgM anti-Toxoplasma antibodies on initial testing during pregnancy. In this study, we assessed and compared the performances of four commercially available Toxoplasma IgG avidity tests in immunocompetent and immunocompromised patients with acute and latent toxoplasmosis. The positive predictive value of high avidity to confirm latent toxoplasmosis was 100% for all the assays, indicating that high avidity is a hallmark of latent infection. However, the negative predictive value of high avidity ranged from 99.2% (bioMérieux) to 95.3% (Abbott), indicating that acute toxoplasmosis could not be reliably diagnosed based on low IgG avidity alone. Thus, the avidity test provides a rapid means for identifying latent Toxoplasma infection in immunocompetent pregnant women presenting both IgG and IgM anti-Toxoplasma antibodies on initial testing. In terms of cost-effectiveness, avidity testing is a powerful tool that optimizes screening and follow-up of pregnant women while minimizing the costs of screening by avoiding subsequent costly maternal and fetal investigation and unnecessary treatment. The cheapest assay, Vidas Toxo IgG Avidity, also had the best performance for the diagnosis of latent toxoplasmosis. PMID:23239801

  5. A new test of computational protein design: predicting posttranslational modification specificity for the enzyme SMYD2.

    PubMed

    Reynolds, Kimberly A

    2015-01-06

    In this issue of Structure, Lanouette and colleagues use a combination of computation and experiment to define a specificity motif for the lysine methyltransferase SMYD2. Using this motif, they predict and experimentally verify four new SMYD2 substrates.

  6. Solenopsis invicta virus 3: Further host-specificity tests with native Solenopsis ants (Hymenoptera: Formicidae)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A thorough understanding of host specificity is essential before pathogens can be used as biopesticides or self-sustaining biocontrol agents. In order to better define the host range of the recently discovered Solenopsis invicta virus 3 (SINV-3), we collected and exposed colonies of two native fire...

  7. Testing specificity among parents' depressive symptoms, parenting, and child internalizing and externalizing symptoms.

    PubMed

    Gruhn, Meredith A; Dunbar, Jennifer P; Watson, Kelly H; Reising, Michelle M; McKee, Laura; Forehand, Rex; Cole, David A; Compas, Bruce E

    2016-04-01

    The present study examined the specificity in relations between observed withdrawn and intrusive parenting behaviors and children's internalizing and externalizing symptoms in an at-risk sample of children (ages 9 to 15 years old) of parents with a history of depression (N = 180). Given past findings that parental depression and parenting behaviors may differentially impact boys and girls, gender was examined as a moderator of the relations between these factors and child adjustment. Correlation and linear regression analyses showed that parental depressive symptoms were significantly related to withdrawn parenting for parents of boys and girls and to intrusive parenting for parents of boys only. When controlling for intrusive parenting, preliminary analyses demonstrated that parental depressive symptoms were significantly related to withdrawn parenting for parents of boys, and this association approached significance for parents of girls. Specificity analyses yielded that, when controlling for the other type of problem (i.e., internalizing or externalizing), withdrawn parenting specifically predicted externalizing problems but not internalizing problems in girls. No evidence of specificity was found for boys in this sample, suggesting that impaired parenting behaviors are diffusely related to both internalizing and externalizing symptoms for boys. Overall, results highlight the importance of accounting for child gender and suggest that targeting improvement in parenting behaviors and the reduction of depressive symptoms in interventions with parents with a history of depression may have potential to reduce internalizing and externalizing problems in this high-risk population.

  8. Assessing Disease Class-Specific Diagnostic Ability: A Practical Adaptive Test Approach.

    ERIC Educational Resources Information Center

    Papa, Frank J.; Schumacker, Randall E.

    Measures of the robustness of disease class-specific diagnostic concepts could play a central role in training programs designed to assure the development of diagnostic competence. In the pilot study, the authors used disease/sign-symptom conditional probability estimates, Monte Carlo procedures, and artificial intelligence (AI) tools to create…

  9. Testing Specificity Among Parents’ Depressive Symptoms, Parenting, and Child Internalizing and Externalizing Symptoms

    PubMed Central

    Gruhn, Meredith A.; Dunbar, Jennifer P.; Watson, Kelly H.; Reising, Michelle M.; McKee, Laura; Forehand, Rex; Cole, David A.; Compas, Bruce E.

    2016-01-01

    The present study examined the specificity in relations between observed withdrawn and intrusive parenting behaviors and children's internalizing and externalizing symptoms in an at risk sample of children (ages 9 to 15-years-old) of parents with a history of depression (N = 180). Given past findings that parental depression and parenting behaviors may differentially impact boys and girls, gender was examined as a moderator of the relations between these factors and child adjustment. Correlation and linear regression analyses showed that parental depressive symptoms were significantly related to withdrawn parenting for parents of boys and girls and to intrusive parenting for parents of boys only. When controlling for intrusive parenting, preliminary analyses demonstrated that parental depressive symptoms were significantly related to withdrawn parenting for parents of boys, and this association approached significance for parents of girls. Specificity analyses yielded that, when controlling for the other type of problem (i.e., internalizing or externalizing), withdrawn parenting specifically predicted externalizing problems but not internalizing problems in girls. No evidence of specificity was found for boys in this sample, suggesting that impaired parenting behaviors are diffusely related to both internalizing and externalizing symptoms for boys. Overall, results highlight the importance of accounting for child gender and suggest that targeting improvement in parenting behaviors and the reduction of depressive symptoms in interventions with parents with a history of depression may have potential to reduce internalizing and externalizing problems in this high-risk population. PMID:26882467

  10. Host specificity testing of the Solenopsis fire ant (Hymenoptera:Formicidae) pathogen, Kneallhazia (=Thelohania) solenopsae (Microsporidia:Thelohaniidae), in Florida

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Post-entry host specificity testing was conducted on ants in Florida for the fire ant pathogen Kneallhazia solenopsae to determine transmission potential to native and non-target species. In addition, there was interest to assess the potential of K. solenopsae to control other pest ants. The patho...

  11. CFL Labeling Harmonization in the United States, China, Brazil andELI Member Countries: Specifications, Testing, and MutualRecognition

    SciTech Connect

    Fridley, David; Lin, Jiang; Denver, Andrea; Biermayer, Peter; Dillavou, Tyler

    2005-07-20

    This report examines critical differences among energy-efficient labeling programs for CFLs in Brazil, China, the United States, and the seven members of the international Efficient Lighting Initiative (ELI) in terms of technical specifications and test procedures, and review issues related to international harmonization of these standards.

  12. Technical Report on Development of USES Specific Aptitude Test Battery for Utility Hand (paper goods) 539.883.

    ERIC Educational Resources Information Center

    Manpower Administration (DOL), Washington, DC.

    Research resulting in the development of the Specific Aptitude Test Battery for use in selecting inexperienced or untrained individuals for training as Utility Hands (paper goods) was described. Aptitudes measured were form perception, clerical perception, and manual dexterity. Job analysis was performed by observation of the workers' performance…

  13. The Slingerland Screening Tests for Identifying Children with Specific Language Disability: Screening for Learning Disabilities in First Grade.

    ERIC Educational Resources Information Center

    Dinero, Thomas E.; And Others

    1979-01-01

    The responses on the Slingerland Screening Tests for identifying children with specific learning disabilities of 29 learning disabled and 11 nondisabled children in Grade 1 distinguished the two groups, except for copying (near vision). Copying (far vision) and auditory, visual, and kinesthetic perception and discrimination together were the…

  14. Taxonomic Notes on the Abyssal Agglutinated Benthic Foraminifera of the HEBBLE (High Energy Benthic Boundary Layer Experiment) Area (Lower Nova Scotian Continental Rise).

    DTIC Science & Technology

    1983-09-01

    Gulf of Mexico . Marine Sciences International, Woods Hole, Ma. Resig, J.M., 1981 Biogeography of benthic foraminifera of the northern Nazca plate and...HD-A133 743 TAXONOMIC NOTES ON THE ABYSSAL AGGLUTINATED BENTHIC t/i FORAMINIFERA OF-THE H..(U) WOODS HOLE OCEANOGRAPHIC INSTITUTION MRN M A KAMINSKI...Notes On The Abyssal Agglutinated Benthic Foraminifera September 1983 Of The HEBBLE Area (Lower Nova Scotian Continental Rise) 7. A41*heeW L Pinforv Mg

  15. Specific 13C functional pathways as diagnostic targets in gastroenterology breath-tests: tricks for a correct interpretation.

    PubMed

    Pizzoferrato, M; Del Zompo, F; Mangiola, F; Lopetuso, L R; Petito, V; Cammarota, G; Gasbarrini, A; Scaldaferri, F

    2013-01-01

    Breath tests are non-invasive, non-radioactive, safe, simple and effective tests able to determine significant metabolic alterations due to specific diseases or lack of specific enzymes. Carbon isotope (13)C, the stable-non radioactive isotope of carbon, is the most used substrate in breath testing, in which (13)C/(12)C ratio is measured and expressed as a delta value, a differences between readings and a fixed standard. (13)C/(12)C ratio is measured with isotope ratio mass spectrometry or non-dispersive isotope-selective infrared spectrometer and generally there is a good agreement between these techniques in the isotope ratio estimation. (13)C/(12)C ratio can be expressed as static measurement (like delta over baseline in urea breath test) or as dynamic measurement as percent dose recovery, but more dosages are necessary. (13)C Breath-tests are involved in many fields of interest within gastroenterology, such as detection of Helicobacter pylori infection, study of gastric emptying, assessment of liver and exocrine pancreatic functions, determination of oro-caecal transit time, evaluation of absorption and to a lesser extend detection of bacterial overgrowth. The use of every single test in a clinical setting is vary depending on accuracy and substrate costs. This review is meant to present (13)C the meaning of (13)C/(12)C ratio and static and dynamic measure and, finally, the instruments dedicated to its use in gastroenterology. A brief presentation of (13)C breath tests in gastroenterology is also provided.

  16. Chlorambucil and bleomycin induce mutations in the specific-locus test in female mice.

    PubMed

    Russell, L B; Hunsicker, P R; Shelby, M D

    1996-10-28

    Specific-locus studies have shown chlorambucil (CHL) and bleomycin (BLE) to be mutagenic in mouse oocytes, almost doubling the number of chemicals previously known to induce mutations in females. The overall CHL-induced mutation rate in oocytes is, however, one order of magnitude below that for male meiotic and postmeiotic stages, and only 1/50 that for early spermatids. For BLE, no specific-locus data for males are available for comparison, but the chemical had earlier been found negative for dominant-lethal induction in males. Both BLE and CHL were significantly mutagenic only in mature and maturing oocytes. In keeping with an earlier report, BLE produced a high incidence of dominant lethals in these stages. CHL failed to induce dominant lethals, indicating that for mature and maturing oocytes, in contrast with results for males, sensitivity to dominant-lethal mutations is not a prerequisite for induction of specific-locus mutations. Exposure of immature oocytes to either BLE or CHL produced neither dominant lethals nor significant induction of specific-locus mutations; however, CHL gave evidence of killing immature oocytes. By contrast, BLE, which has been considered a radiomimetic chemical, does not appear to kill immature oocytes and thus differs markedly from radiation exposures equivalent for dominant-lethal induction. Therefore, the failure to recover specific-locus mutations cannot be ascribed to cell selection resulting from oocyte killing, as has sometimes been done for radiation. Adding results on the nature of the CHL- and BLE-induced mutations to prior information, the estimated minimum proportion of large DNA lesions induced in oocytes by chemicals becomes 35.3%, significantly different from the corresponding figure (approximately 70%) for radiations. For chemical treatments, the oocyte proportion is highly significantly above the 3.6% induced in spermatogonia, but only on the borderline of statistically significant difference from that induced in

  17. Prostate-specific antigen test use and digital rectal examinations among African-American men, 2002-2006.

    PubMed

    Ross, Louie E; Meade, Shelly-Ann; Powe, Barbara D; Howard, Daniel L

    2009-07-01

    African-American men experience greater incidence and mortality from prostate cancer compared to White men as well as men from other groups. Few studies have examined prostate-specific antigen (PSA) test and digital rectal examination (DRE) use in African-American men. This study examined use of the PSA test and DRE among African-American men over time and identified correlates associated with the use of these procedures. Overall trends for years 2002-2006 showed a significant decrease in recent PSA test use and DRE among African-American men in 2004 and 2006 compared to year 2002. Recent PSA test use and DRE were associated with several factors including older ages, being married, higher levels of education and income, and overweight and obese body mass index (BMI). PSA test use and DRE among African-American men should be monitored over time to find out if this pattern continues.

  18. Dual Immunomagnetic Nanobeads-Based Lateral Flow Test Strip for Simultaneous Quantitative Detection of Carcinoembryonic Antigen and Neuron Specific Enolase

    PubMed Central

    Lu, Wenting; Wang, Kan; Xiao, Kun; Qin, Weijian; Hou, Yafei; Xu, Hao; Yan, Xinyu; Chen, Yanrong; Cui, Daxiang; He, Jinghua

    2017-01-01

    A novel immunomagnetic nanobeads -based lateral flow test strip was developed for the simultaneous quantitative detection of neuron specific enolase (NSE) and carcinoembryonic antigen (CEA), which are sensitive and specific in the clinical diagnosis of small cell lung cancer. Using this nanoscale method, high saturation magnetization, carboxyl-modified magnetic nanobeads were successfully synthesized. To obtain the immunomagnetic probes, a covalent bioconjugation of the magnetic nanobeads with the antibody of NSE and CEA was carried out. The detection area contained test line 1 and test line 2 which captured the immune complexes sensitively and formed sandwich complexes. In this assay, cross-reactivity results were negative and both NSE and CEA were detected simultaneously with no obvious influence on each other. The magnetic signal intensity of the nitrocellulose membrane was measured by a magnetic assay reader. For quantitative analysis, the calculated limit of detection was 0.094 ng/mL for NSE and 0.045 ng/mL for CEA. One hundred thirty clinical samples were used to validate the test strip which exhibited high sensitivity and specificity. This dual lateral flow test strip not only provided an easy, rapid, simultaneous quantitative detection strategy for NSE and CEA, but may also be valuable in automated and portable diagnostic applications. PMID:28186176

  19. Development of site-specific sediment no-effect concentrations based on synoptic chemical analyses and toxicity testing

    SciTech Connect

    Sferra, J.; Barber, T.; Fuchsman, P.; Sheehan, P.

    1995-12-31

    Site-specific maximum observed no-effect concentrations (MONECs) were developed using sediment chemistry and toxicity test data concomitantly collected from 33 sample locations in a river system adjacent to a RCRA facility in Ohio. Physical and chemical analyses included VOCs, SVOCs, metals, pesticides and PCBs, acid volatile sulfides and simultaneously extracted metals, ammonia, total organic carbon and grain size. Concentrations of hydrophobic, non-polar organic compounds were normalized to 1% total organic carbon contents, as the bioavailability of these compounds was considered to be primarily controlled by sediment organic carbon content through adsorption. Toxicity tests conducted using Chironomus tentans and Hyalella azteca were analyzed for impacts to survival and growth endpoints for both species. Samples were separated into two categories for each test endpoint, depending on whether toxicity was observed. MONECs were defined as the highest measured chemical concentration that did not produce a significant effect in toxicity tests. MONEC values were derived for each species and test endpoint, and the lowest of these four values was adopted as the site-specific MONEC for each chemical. Site-specific MONECs were used as a tool to assist in the identification of chemicals contributing to observed sediment toxicity.

  20. Proceedings: Nozzle Initiative Industry Advisory Committee on standardization of carbon-phenolic test methods and specifications

    NASA Astrophysics Data System (ADS)

    Hall, William B.

    1992-08-01

    Verbal discussions during the biannual meeting of the Industry Advisory Committee for Carbon-phenolic constituent test methodology, which is constituted under the Solid Propulsion Integrity Program (SPIP), are addressed. The items on the agenda are: (1) NASA video tape library; (2) product code identification; (3) NMR progress; (4) IR and DMTA workshop; (5) aerospace database update; (6) M vision database demonstration; (7) constituent fingerprinting; (8) cured materials test development; (9) engineering needs for computer modeling; and (10) review action items. The materials prepared to support some of the oral presentations are also included in the Appendix.

  1. The NASA broad-specification fuels combustion technology program: An assessment of phase 1 test results

    NASA Technical Reports Server (NTRS)

    Fear, J. S.

    1983-01-01

    An assessment is made of the results of Phase 1 screening testing of current and advanced combustion system concepts using several broadened-properties fuels. The severity of each of several fuels-properties effects on combustor performance or liner life is discussed, as well as design techniques with the potential to offset these adverse effects. The selection of concepts to be pursued in Phase 2 refinement testing is described. This selection takes into account the relative costs and complexities of the concepts, the current outlook on pollutant emissions control, and practical operational problems.

  2. Proceedings: Nozzle Initiative Industry Advisory Committee on standardization of carbon-phenolic test methods and specifications

    NASA Technical Reports Server (NTRS)

    Hall, William B.

    1992-01-01

    Verbal discussions during the biannual meeting of the Industry Advisory Committee for Carbon-phenolic constituent test methodology, which is constituted under the Solid Propulsion Integrity Program (SPIP), are addressed. The items on the agenda are: (1) NASA video tape library; (2) product code identification; (3) NMR progress; (4) IR and DMTA workshop; (5) aerospace database update; (6) M vision database demonstration; (7) constituent fingerprinting; (8) cured materials test development; (9) engineering needs for computer modeling; and (10) review action items. The materials prepared to support some of the oral presentations are also included in the Appendix.

  3. Mission Control Center (MCC) system specification for the shuttle Orbital Flight Test (OFT) timeframe

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The Mission Control Center Shuttle (MCC) Shuttle Orbital Flight Test (OFT) Data System (OFTDS) provides facilities for flight control and data systems personnel to monitor and control the Shuttle flights from launch (tower clear) to rollout (wheels stopped on runway). It also supports the preparation for flight (flight planning, flight controller and crew training, and integrated vehicle and network testing activities). The MCC Shuttle OFTDS is described in detail. Three major support systems of the OFTDS and the data types and sources of data entering or exiting the MCC were illustrated. These systems are the communication interface system, the data computation complex, and the display and control system.

  4. Discordance between Aeroallergen Specific Serum IgE and Skin Testing in Children < 4 years of age

    PubMed Central

    de Vos, Gabriele; Nazari, Ramin; Ferastraoaru, Denisa; Parikh, Purvi; Geliebter, Rebecca; Pichardo, Yikania; Wiznia, Andrew; Rosenstreich, David

    2015-01-01

    Background Atopic sensitization to aeroallergens in early life has been shown to be a strong risk factor for developing persisting asthma in young children with recurrent wheeze. Objective The aim of this study was to assess the yield of skin prick test (SPT) compared to allergen specific serum IgE testing (sIgE) at identifying aeroallergen sensitization in atopic children < 4 years of age. Methods Concordance between SPT (Greer Laboratories, ComforTen™) and allergen specific sIgE (Immulite 2000™) for 7 common aeroallergens was analyzed in forty atopic inner-city children, 18–48 months of age (mean 36 +/− 9 months) with recurrent wheezing, family history of asthma and/or eczema. Results In 80% of children one or more allergen sensitizations would have been missed if only SPT had been performed, and in 38% of children one or more sensitizations would have been missed if only serum IgE testing had been performed. Agreement and between SPT and sIgE test was fair for most allergens (kappa between −0.04 and 0.50), as was correlation between sIgE levels and SPT grade (rho between 0.21 and 0.55). Children with high total sIgE (≥300 kU/l) were more likely to have sIgE positive tests with negative corresponding skin test (p=0.025). Conclusions Our study showed significant discordance between allergen specific SPT and sIgE testing results for common aeroallergens, suggesting that both SPT and sIgE testing should be done when diagnosing allergic sensitization in young children at high risk of asthma. PMID:23706713

  5. The Hoff circuit test is more specific than an incremental treadmill test to assess endurance with the ball in youth soccer players.

    PubMed

    Zagatto, A M; Papoti, M; Da Silva, Asr; Barbieri, R A; Campos, E Z; Ferreira, E C; Loures, J P; Chamari, K

    2016-09-01

    The assessment of aerobic endurance is important for training prescription in soccer, and is usually measured by straight running without the ball on a track or treadmill. Due to the ball control and technical demands during a specific soccer test, the running speeds are likely to be lower compared to a continuous incremental test. The aim of the present study was to compare the heart rate (HR), rating of perceived exertion (RPE) and speeds corresponding to 2.0 mmol∙L(-1), 3.5 mmol∙L(-1), lactate threshold (Dmax method) and peak lactate determined in the laboratory and in the Hoff circuit soccer-specific test. Sixteen soccer players (16±1 years) underwent two incremental tests (laboratory and Hoff circuit tests). The speeds were significantly higher in the treadmill test than on the Hoff circuit (2.0 mmol∙L(-1): 9.5±1.2 and 8.1±1.0 km∙h(-1); 3.5 mmol∙L(-1): 12.0±1.2 and 10.2±1.1 km∙h(-1); Dmax: 11.4±1.4 and 9.3±0.4 km∙h(-1); peak lactate: 14.9±1.6 and 10.9±0.8 km∙h(-1)). The HR corresponding to 3.5 mmol∙L-1 was significantly higher on the Hoff circuit compared to the laboratory test (187.5±18.0 and 178.2±17.6 bpm, respectively; P <0.001), while the RPE at the last incremental stage was lower on the Hoff circuit (P < 0.01). The speeds during the Hoff specific soccer test and the HR corresponding to 2.0 mmol∙L(-1), 3.5 mmol∙L(-1) and Dmax/threshold were different compared with the laboratory test. The present study shows that it is possible to assess submaximal endurance related variables specifically in soccer players.

  6. A critical review of published methods for analysis of red cell antigen-antibody reactions by flow cytometry, and approaches for resolving problems with red cell agglutination.

    PubMed

    Arndt, Patricia A; Garratty, George

    2010-07-01

    Flow cytometry operators often apply familiar white blood cell (WBC) methods when studying red blood cell (RBC) antigens and antibodies. Some WBC methods are not appropriate for RBCs, as the analysis of RBCs requires special considerations, for example, avoidance of agglutination. One hundred seventy-six published articles from 88 groups studying RBC interactions were reviewed. Three fourths of groups used at least one unnecessary WBC procedure for RBCs, and about one fourth did not use any method to prevent/disperse RBC agglutination. Flow cytometric studies were performed to determine the effect of RBC agglutination on results and compare different methods of preventing and/or dispersing agglutination. The presence of RBC agglutinates have been shown to be affected by the type of pipette tip used for mixing RBC suspensions, the number of antigen sites/RBC, the type and concentration of primary antibody, and the type of secondary antibody. For quantitation methods, for example, fetal maternal hemorrhage, the presence of agglutinates have been shown to adversely affect results (fewer fetal D+ RBCs detected).

  7. Alcohol expectancy and drinking refusal self-efficacy: a test of specificity theory.

    PubMed

    Oei, T P; Burrow, T

    2000-01-01

    Although alcohol expectancy (expectations about the effects of drinking alcohol on one's behavior and mood) and drinking refusal self-efficacy (one's perceived ability to resist drinking in high-risk situations) have consistently been demonstrated to be useful to our understanding of alcohol use and abuse, the specificity of these constructs to alcohol consumption has not been previously demonstrated. Using 161 first-year psychology students and multiple regression analyses this study indicated that alcohol expectancies and drinking refusal self-efficacy were specifically related to quantity of alcohol consumption, but not to caffeine or nicotine intake. These results provide empirical evidence to confirm the theoretical and practical utility of these two cognitive constructs to alcohol research and serve to strengthen the theoretical foundations of alcohol expectancy theory.

  8. Sex-Specific Differential Prediction of College Admission Tests: A Meta-Analysis

    ERIC Educational Resources Information Center

    Fischer, Franziska T.; Schult, Johannes; Hell, Benedikt

    2013-01-01

    This is the first meta-analysis that investigates the differential prediction of undergraduate and graduate college admission tests for women and men. Findings on 130 independent samples representing 493,048 students are summarized. The underprediction of women's academic performance (d = 0.14) and the overprediction of men's academic performance…

  9. Data-Division-Specific Robustness and Power of Randomization Tests for ABAB Designs

    ERIC Educational Resources Information Center

    Manolov, Rumen; Solanas, Antonio; Bulte, Isis; Onghena, Patrick

    2010-01-01

    This study deals with the statistical properties of a randomization test applied to an ABAB design in cases where the desirable random assignment of the points of change in phase is not possible. To obtain information about each possible data division, the authors carried out a conditional Monte Carlo simulation with 100,000 samples for each…

  10. [Test for bioenergetic progress and specific energy metabolism in isopod crustaceans (Isopoda) of various ecology].

    PubMed

    Kleĭmenov, S Iu; Alekseeva, T A

    2002-01-01

    We studied energy metabolism of terrestrial and cavernicolous isopods and demonstrated much lower standard metabolism in the troglobionts as compared to other Isopoda representatives. The test for bioenergetic progress proved to be applicable for both aromorphosis and katamorphosis. Different patterns of the relationship between energy metabolism and temperature in stenothermal and eurythermal species have been proposed.

  11. Cultivating Assessment Literacy: Standards Evaluation through Language-Test Specification Reverse Engineering

    ERIC Educational Resources Information Center

    Walters, F. Scott

    2010-01-01

    The promulgation of ESL learning standards by government agencies and professional organizations is intended to improve second-language (L2) proficiency and academic achievement. However, mandates have been criticized on various grounds, including difficulty of defining domains to be tested as well as vagueness of articulation. Arising from the…

  12. A Classroom-Based Assessment Method to Test Speaking Skills in English for Specific Purposes

    ERIC Educational Resources Information Center

    Alberola Colomar, María Pilar

    2014-01-01

    This article presents and analyses a classroom-based assessment method to test students' speaking skills in a variety of professional settings in tourism. The assessment system has been implemented in the Communication in English for Tourism course, as part of the Tourism Management degree programme, at Florida Universitaria (affiliated to the…

  13. SELECTING AND EVALUATING NATIVE PLANTS FOR REGION-SPECIFIC PHYTOTOXICITY TESTING

    EPA Science Inventory

    In this study, we evaluated methodology to determine risks to terrestrial native plant species from potential herbicide drift, focusing on 1) selection of native species for testing, 2) growth of these species, and 3) variability in herbicide response among native species and com...

  14. Test Anxiety Among College Students With Specific Reading Disability (Dyslexia): Nonverbal Ability and Working Memory as Predictors.

    PubMed

    Nelson, Jason M; Lindstrom, Will; Foels, Patricia A

    2015-01-01

    Test anxiety and its correlates were examined with college students with and without specific reading disability (RD; n = 50 in each group). Results indicated that college students with RD reported higher test anxiety than did those without RD, and the magnitude of these differences was in the medium range on two test anxiety scales. Relative to college students without RD, up to 5 times as many college students with RD reported clinically significant test anxiety. College students with RD reported significantly higher cognitively based test anxiety than physically based test anxiety. Reading skills, verbal ability, and processing speed were not correlated with test anxiety. General intelligence, nonverbal ability, and working memory were negatively correlated with test anxiety, and the magnitude of these correlations was medium to large. When these three cognitive constructs were considered together in multiple regression analyses, only working memory and nonverbal ability emerged as significant predictors and varied based on the test anxiety measure. Implications for assessment and intervention are discussed.

  15. Sulfurtransferase and thioredoxin specifically interact as demonstrated by bimolecular fluorescence complementation analysis and biochemical tests

    PubMed Central

    Henne, Melina; König, Nicolas; Triulzi, Tiziana; Baroni, Sara; Forlani, Fabio; Scheibe, Renate; Papenbrock, Jutta

    2015-01-01

    Sulfurtransferases (Strs) and thioredoxins (Trxs) are members of large protein families. Trxs are disulfide reductases and play an important role in redox-related cellular processes. They interact with a broad range of proteins. Strs catalyze the transfer of a sulfur atom from a suitable sulfur donor to nucleophilic sulfur acceptors in vitro, but the physiological roles of these enzymes are not well defined. Several studies in different organisms demonstrate protein–protein interactions of Strs with members of the Trx family. We are interested in investigating the specificity of the interaction between Str and Trx isoforms. In order to use the bimolecular fluorescence complementation (BiFC), several Str and Trx sequences from Arabidopsis thaliana were cloned into the pUC-SPYNE and pUC-SPYCE split-YFP vectors, respectively. Each couple of plasmids containing the sequences for the putative interaction partners were transformed into Arabidopsis protoplasts and screened using a confocal laser scanning microscope. Compartment- and partner-specific interactions could be observed in transformed protoplasts. Replacement of cysteine residues in the redox-active site of Trxs abolished the interaction signal. Therefore, the redox site is not only involved in the redox reaction but also responsible for the interaction with partner proteins. Biochemical assays support a specific interaction among Strs and certain Trxs. Based on the results obtained, the interaction of Strs and Trxs indicates a role of Strs in the maintenance of the cellular redox homeostasis. PMID:26605137

  16. Development of a rowing-specific VO2max field test.

    PubMed

    Huntsman, Heather D; DiPietro, Loretta; Drury, Daniel G; Miller, Todd A

    2011-06-01

    The purpose of this study was to develop an aerobic capacity test for rowers using minimal equipment that could be used in the field. Thirty rowers (15 men and 15 women) between the ages of 18 and 26 years were recruited on a volunteer basis from the District of Columbia metro area. The testing protocol consisted of a maximum of 7 2-minute stages on a rowing ergometer, separated by 30-second breaks where lactic acid concentrations were analyzed. Starting intensity for men was 200 W, although women started at 150 W, and each stage increased by 50 W. Expired gasses were collected during the test, and athletes were asked to row until maximal volition so that the directly measured VO2max could be compared to predicted values. Peak heart rates from each completed stage were plotted, and regression equations were calculated to predict VO2max. Separate regression equations were calculated for men and women. The predicted VO2max values were approximately 23 and 25% lower than what was actually achieved for men and women, respectively. Heart rate was a stronger correlate of VO2max in men compared with in women. Among men, we observed a moderate and statistically significant correlation (r = 0.55; p = 0.05), whereas among women, no such agreement was observed (r = -0.05; p > 0.85). The principle finding of this study was that the test was adequate in predicting VO2max in men but was inadequate in its prediction in women. With slight modifications to the testing protocol, stronger correlations and a more accurate prediction of VO2max is expected in men.

  17. Comparison of serological tests for the detection of ovine and caprine antibody to Brucella melitensis.

    PubMed

    Nielsen, K; Gall, D; Smith, P; Balsevicius, S; Garrido, F; Ferrer, M Durán; Biancifiori, F; Dajer, A; Luna, E; Samartino, L; Bermudez, R; Moreno, F; Renteria, T; Corral, A

    2004-12-01

    The indirect enzyme-linked immunosorbent assay (IELISA), the competitive enzyme-linked immunosorbent assay (CELISA) and the fluorescence polarisation assay (FPA) were evaluated with sera from sheep experimentally infected with Brucella melitensis and negative Canadian sheep. The sensitivity and specificity of the assays were as follows: IELISA: 91.7% and 97.6%, CELISA: 75.0% and 99.8% and FPA: 91.7% and 89.5%. Sera from the same experimental population were divided according to serological reaction in the rose bengal agglutination test (RBT) and the complement fixation test (CFT). Reactivity relative to the RBT positive and CFT positive sera were as follows: IELISA: 99.7%, CELISA: 93.2% and FPA: 99.1%. Since sera from goats with proven B. melitensis infection were not available, 699 sera from goats judged positive in the buffered antigen plate agglutination test (BPAT) and CFT and 982 BPAT/CFT negative Canadian goats were used. The sensitivity and specificity of the assays relative to the BPAT and CFT positive sera were: IELISA: 99.4% and 98.0%, CELISA: 95.4% and 97.1% and FPA: 92.7% and 99.8%.

  18. A rhamnose-binding lectin from sea bass (Dicentrarchus labrax) plasma agglutinates and opsonizes pathogenic bacteria.

    PubMed

    Cammarata, Matteo; Parisi, Maria Giovanna; Benenati, Gigliola; Vasta, Gerardo R; Parrinello, Nicolò

    2014-06-01

    The discovery of rhamnose-binding lectins (RBLs) in teleost fish eggs led to the identification of a novel lectin family characterized by a unique sequence motif and a structural fold, and initially proposed to modulate fertilization. Further studies of the RBL tissue localization and gene organization were also suggestive of role(s) in innate immunity. Here we describe the purification, and biochemical and functional characterization of a novel RBL (DlRBL) from sea bass (Dicentrarchus labrax) serum. The purified DlRBL had electrophoretic mobilities corresponding to 24 kDa and 100 kDa under reducing and non-reducing conditions, respectively, suggesting that in plasma the DlRBL is present as a physiological homotetramer. DlRBL subunit transcripts revealed an open reading frame encoding 212 amino acid residues that included two tandemly-arrayed carbohydrate-recognition domains, and an 18-residue signal sequence at the N-terminus. The deduced size of 24.1 kDa for the mature protein was in good agreement with the subunit size of the isolated lectin. Binding activity of DlRBL for rabbit erythrocytes could be inhibited in the presence of rhamnose or galactose, did not require calcium, and was optimal at around 20°C and within the pH 6.5-8.0 range. DlRBL agglutinated Gram positive and Gram negative bacteria, and exposure of formalin-killed Escherichia coli to DlRBL enhanced their phagocytosis by D. labrax peritoneal macrophages relative to the unexposed controls. Taken together, the results suggest that plasma DlRBL may play a role in immune recognition of microbial pathogens and facilitate their clearance by phagocytosis.

  19. Comparative study of immunofluorescent antinuclear antibody test and line immunoassay detecting 15 specific autoantibodies in patients with systemic rheumatic disease.

    PubMed

    Lee, Sun Ah; Kahng, Jimin; Kim, Yonggoo; Park, Yeon-Joon; Han, Kyungja; Kwok, Seung-Ki; Park, Sung-Hwan; Oh, Eun-Jee

    2012-07-01

    Based on the currently proposed algorithms, antibodies specificities (sp-ANAs) are identified mainly in samples positive for fluorescent antinuclear antibodies (FANA) screening tests. The purpose of the present study was to compare diagnostic performances of FANA and line immune assay (LIA) detecting 15 sp-ANAs in patients with systemic rheumatic diseases (SRD). In 948 sera from the patients with SRD (n = 590) and non-SRD (n = 358), we evaluated the fluorescent patterns and intensities in the FANA test, and compared the FANA results with sp-ANAs against nRNP, Sm, SS-A, Ro52, SS-B, Scl-70, PM/Scl, Jo-1, CENP B, PCNA, dsDNA, nucleosome, histone, ribosomal-P, and M2. The sensitivity and specificity was 75.9% and 52.5% of FANA test and 62.0% and 84.4% of sp-ANAs test for SRD detection. The overall agreement between FANA and sp-ANAs results was 69.2% (Kappa coefficient; 0.404). According to the clinical diagnosis, the levels of agreement varied from 33.3% to 83.1%. The positive predictive values of each FANA pattern for the detection of sp-ANAs were less than 50% except for the discrete speckled pattern (91.7%). The 1:100 intensity of FANA as well as the monoreactivity of LIA, anti-SSA(-)/anti-Ro52(+), or FANA(-)/sp-ANAs(+) was associated with non-SRD. Antibodies against ribosomal-P or PCNA were specific for systemic lupus eryhthematosus. This study highlights the need for careful interpretation of FANA test results to assess sp-ANAs and the application of sp-ANAs tests including less-common autoantibodies. In patients with clinical suspicion of SRD, screening with both FANA and sp-ANAs tests could improve diagnostic efficiency.

  20. Bayesian estimation of sensitivity and specificity of Coxiella burnetii antibody ELISA tests in bovine blood and milk.

    PubMed

    Paul, Suman; Toft, Nils; Agerholm, Jørgen S; Christoffersen, Anna-Bodil; Agger, Jens F

    2013-05-01

    Serological tests for Coxiella burnetii (the causative agent of Q fever) antibodies are usually based on enzyme linked immunosorbent assay (ELISA) although this method is not thoroughly evaluated. The objective of this study was to determine the sensitivity and specificity of an ELISA for detection of C. burnetii antibodies in milk and blood samples, using latent class models in a Bayesian analysis. Blood and milk samples of 568 lactating cows from 17 Danish dairy cattle herds collected in 2008 were used. The best combination of sensitivity and specificity estimates was revealed at a sample to positive (S/P) cut-off of 40 for both blood and milk ELISAs. At this cut-off, sensitivity of milk ELISA was 0.86 (95% posterior credibility interval [PCI] [0.76; 0.96]). This was slightly but insignificantly higher than sensitivity of blood ELISA (0.84; 95% PCI [0.75; 0.93]). The specificity estimates of the ELISA methods on milk and blood were equal at 0.99. No conditional dependence was observed between the specificity estimates of the two test methods. However, the sensitivity estimates of both tests were significantly reduced when conditional covariances ≥ 40 were used. Collection of milk samples from lactating cows is relatively easy, non-invasive and inexpensive and hence milk ELISA may be a better option for screening lactating cows. But, blood ELISA is an option for screening non-lactating cattle.