Science.gov

Sample records for aided drafting cad

  1. Preparing Students for Computer Aided Drafting (CAD). A Conceptual Approach.

    ERIC Educational Resources Information Center

    Putnam, A. R.; Duelm, Brian

    This presentation outlines guidelines for developing and implementing an introductory course in computer-aided drafting (CAD) that is geared toward secondary-level students. The first section of the paper, which deals with content identification and selection, includes lists of mechanical drawing and CAD competencies and a list of rationales for…

  2. A Multidisciplinary Research Team Approach to Computer-Aided Drafting (CAD) System Selection. Final Report.

    ERIC Educational Resources Information Center

    Franken, Ken; And Others

    A multidisciplinary research team was assembled to review existing computer-aided drafting (CAD) systems for the purpose of enabling staff in the Design Drafting Department at Linn Technical College (Missouri) to select the best system out of the many CAD systems in existence. During the initial stage of the evaluation project, researchers…

  3. Revision of Electro-Mechanical Drafting Program to Include CAD/D (Computer-Aided Drafting/Design). Final Report.

    ERIC Educational Resources Information Center

    Snyder, Nancy V.

    North Seattle Community College decided to integrate computer-aided design/drafting (CAD/D) into its Electro-Mechanical Drafting Program. This choice necessitated a redefinition of the program through new curriculum and course development. To initiate the project, a new industrial advisory council was formed. Major electronic and recruiting firms…

  4. Selection and implementation of a computer aided design and drafting (CAD/D) system

    SciTech Connect

    Davis, J.P.

    1981-01-01

    Faced with very heavy workloads and limited engineering and graphics personnel, Transco opted for a computer-aided design and drafting system that can produce intelligent drawings, which have associated data bases that can be integrated with other graphical and nongraphical data bases to form comprehensive sets of data for construction projects. Because so much time was being spent in all phases of materials and inventory control, Transco decided to integrate materials-management capabilities into the CAD/D system. When a specific item of material is requested on the graphics equipment, the request triggers production of both the drawing and a materials list. Transco plans to extend its computer applications into mapping tasks as well.

  5. Computer Aided Drafting. Instructor's Guide.

    ERIC Educational Resources Information Center

    Henry, Michael A.

    This guide is intended for use in introducing students to the operation and applications of computer-aided drafting (CAD) systems. The following topics are covered in the individual lessons: understanding CAD (CAD versus traditional manual drafting and care of software and hardware); using the components of a CAD system (primary and other input…

  6. Mechanical Drafting with CAD. Teacher Edition.

    ERIC Educational Resources Information Center

    McClain, Gerald R.

    This instructor's manual contains 13 units of instruction for a course on mechanical drafting with options for using computer-aided drafting (CAD). Each unit includes some or all of the following basic components of a unit of instruction: objective sheet, suggested activities for the teacher, assignment sheets and answers to assignment sheets,…

  7. Computer Aided Drafting Workshop. Workshop Booklet.

    ERIC Educational Resources Information Center

    Goetsch, David L.

    This mini-course and article are presentations from a workshop on computer-aided drafting. The purpose of the mini-course is to assist drafting instructors in updating their occupational knowledge to include computer-aided drafting (CAD). Topics covered in the course include general computer information, the computer in drafting, CAD terminology,…

  8. Integrated Computer-Aided Drafting Instruction (ICADI).

    ERIC Educational Resources Information Center

    Chen, C. Y.; McCampbell, David H.

    Until recently, computer-aided drafting and design (CAD) systems were almost exclusively operated on mainframes or minicomputers and their cost prohibited many schools from offering CAD instruction. Today, many powerful personal computers are capable of performing the high-speed calculation and analysis required by the CAD application; however,…

  9. The polar phase response property of monopolar ECG voltages using a Computer-Aided Design and Drafting (CAD)-based data acquisition system.

    PubMed

    Goswami, B; Mitra, M; Nag, B; Mitra, T K

    1993-11-01

    The present paper discusses a Computer-Aided Design and Drafting (CAD) based data acquisition and polar phase response study of the ECG. The scalar ECG does not show vector properties although such properties are embedded in it. In the present paper the polar phase response property of monopolar chest lead (V1 to V6) ECG voltages has been studied. A software tool has been used to evaluate the relative phase response of ECG voltages. The data acquisition of monopolar ECG records of chest leads V1 to V6 from the chart recorder has been done with the help of the AutoCAD application package. The spin harmonic constituents of ECG voltages are evaluated at each harmonic plane and the polar phase responses are studied at each plane. Some interesting results have been observed in some typical cases which are discussed in the paper. PMID:8307653

  10. Pipe Drafting with CAD. Teacher Edition.

    ERIC Educational Resources Information Center

    Smithson, Buddy

    This teacher's guide contains nine units of instruction for a course on computer-assisted pipe drafting. The course covers the following topics: introduction to pipe drafting with CAD (computer-assisted design); flow diagrams; pipe and pipe components; valves; piping plans and elevations; isometrics; equipment fabrication drawings; piping design…

  11. A Suggested Computer Aided Drafting Curriculum (Dacum Based).

    ERIC Educational Resources Information Center

    Pedras, Melvin J.; Hoggard, David

    Computer-aided drawing can bring new technology into the drafting classroom. One approach to computer-aided drafting (CAD) involves use of a personal computer and purchased software. Existing school computers could be shared to reduce costs. Following this narrative introduction, a suggested curriculum for the teaching of CAD is presented in…

  12. Computer-Aided Drafting. Education for Technology Employment.

    ERIC Educational Resources Information Center

    Northern Illinois Univ., De Kalb. Dept. of Technology.

    This computer-aided drafting (CAD) curriculum was developed to provide drafting instructors in Illinois with a useful guide for relating an important new technological advance to the vocational classroom. The competency-based learning activity guides are written to be used with any CAD system being used at the secondary and postsecondary levels.…

  13. PC Board Layout and Electronic Drafting with CAD. Teacher Edition.

    ERIC Educational Resources Information Center

    Bryson, Jimmy

    This teacher's guide contains 11 units of instruction for a course on computer electronics and computer-assisted drafting (CAD) using a personal computer (PC). The course covers the following topics: introduction to electronic drafting with CAD; CAD system and software; basic electronic theory; component identification; basic integrated circuit…

  14. Continuity of computer-aided drafting operations

    SciTech Connect

    Jacobson, L.D.

    1987-09-01

    The operating performance, operating procedures, and equipment added are discussed for the Computer Aided Drafting (CAD) operation at UNC Nuclear Industries before consolidation of operating contracts at the US Department of Energy (DOE) facilities located at the Hanford Site, near Richland, Washington.

  15. Computer Aided Drafting Curriculum for Vocational Drafting. A Competency Based Unit of Instruction. Final Report.

    ERIC Educational Resources Information Center

    Peck, Greg

    This document contains (1) the final report of a project to develop a computer-aided drafting (CAD) curriculum and (2) a competency-based unit of instruction for use with the CADAPPLE system. The final report states the problem and project objective, presents conclusions and recommendations, and includes survey instruments. The unit is designed…

  16. Computer-aided diagnosis (CAD) for colonoscopy

    NASA Astrophysics Data System (ADS)

    Gu, Jia; Poirson, Allen

    2007-03-01

    Colorectal cancer is the second leading cause of cancer deaths, and ranks third for new cancer cases and cancer mortality for both men and women. However, its death rate can be dramatically reduced by appropriate treatment when early detection is available. The purpose of colonoscopy is to identify and assess the severity of lesions, which may be flat or protruding. Due to the subjective nature of the examination, colonoscopic proficiency is highly variable and dependent upon the colonoscopist's knowledge and experience. An automated image processing system providing an objective, rapid, and inexpensive analysis of video from a standard colonoscope could provide a valuable tool for screening and diagnosis. In this paper, we present the design, functionality and preliminary results of its Computer-Aided-Diagnosis (CAD) system for colonoscopy - ColonoCAD TM. ColonoCAD is a complex multi-sensor, multi-data and multi-algorithm image processing system, incorporating data management and visualization, video quality assessment and enhancement, calibration, multiple view based reconstruction, feature extraction and classification. As this is a new field in medical image processing, our hope is that this paper will provide the framework to encourage and facilitate collaboration and discussion between industry, academia, and medical practitioners.

  17. Computer-aided-diagnosis (CAD) for colposcopy

    NASA Astrophysics Data System (ADS)

    Lange, Holger; Ferris, Daron G.

    2005-04-01

    Uterine cervical cancer is the second most common cancer among women worldwide. Colposcopy is a diagnostic method, whereby a physician (colposcopist) visually inspects the lower genital tract (cervix, vulva and vagina), with special emphasis on the subjective appearance of metaplastic epithelium comprising the transformation zone on the cervix. Cervical cancer precursor lesions and invasive cancer exhibit certain distinctly abnormal morphologic features. Lesion characteristics such as margin; color or opacity; blood vessel caliber, intercapillary spacing and distribution; and contour are considered by colposcopists to derive a clinical diagnosis. Clinicians and academia have suggested and shown proof of concept that automated image analysis of cervical imagery can be used for cervical cancer screening and diagnosis, having the potential to have a direct impact on improving women"s health care and reducing associated costs. STI Medical Systems is developing a Computer-Aided-Diagnosis (CAD) system for colposcopy -- ColpoCAD. At the heart of ColpoCAD is a complex multi-sensor, multi-data and multi-feature image analysis system. A functional description is presented of the envisioned ColpoCAD system, broken down into: Modality Data Management System, Image Enhancement, Feature Extraction, Reference Database, and Diagnosis and directed Biopsies. The system design and development process of the image analysis system is outlined. The system design provides a modular and open architecture built on feature based processing. The core feature set includes the visual features used by colposcopists. This feature set can be extended to include new features introduced by new instrument technologies, like fluorescence and impedance, and any other plausible feature that can be extracted from the cervical data. Preliminary results of our research on detecting the three most important features: blood vessel structures, acetowhite regions and lesion margins are shown. As this is a new

  18. CBT Pilot Program Instructional Guide. Basic Drafting Skills Curriculum Delivered through CAD Workstations and Artificial Intelligence Software.

    ERIC Educational Resources Information Center

    Smith, Richard J.; Sauer, Mardelle A.

    This guide is intended to assist teachers in using computer-aided design (CAD) workstations and artificial intelligence software to teach basic drafting skills. The guide outlines a 7-unit shell program that may also be used as a generic authoring system capable of supporting computer-based training (CBT) in other subject areas. The first section…

  19. Content and Strategies for Teaching Computer Aided Drafting.

    ERIC Educational Resources Information Center

    Becker, Kurt

    1991-01-01

    A Delphi panel of 15 experts determined that (1) computer-assisted drafting (CAD) and traditional drafting are complementary; (2) differences in teaching strategies related to use of computers versus traditional drafting instruments; and (3) traditional drafting knowledge and skills are very important for CAD. (SK)

  20. TRAD or CAD? A Comparison.

    ERIC Educational Resources Information Center

    Resetarits, Paul J.

    1989-01-01

    Studies whether traditional drafting equipment (TRAD) or computer aided drafting equipment (CAD) is more effective. Proposes that students using only CAD can learn principles of drafting as well as students using only TRAD. Reports no significant difference either on achievement or attitude. (MVL)

  1. The Correlation between Visual-Haptic Perceptual Style and Student Ability To Solve Orthographic Projection Problems in a Beginning College Drafting Course Incorporating Computer Aided Drafting.

    ERIC Educational Resources Information Center

    Baird, David A.

    A study determined the effectiveness of computer-aided drafting (CAD) and standard drafting instruction on the ability of students with differing visual-haptic perceptual styles to solve orthographic projection problems. A 2x2x2 factorial design was chosen to compare two levels of perceptual style with two levels of treatment and two levels of…

  2. Computer Aided Drafting Packages for Secondary Education. Edition 1. Apple II and Macintosh. A MicroSIFT Quarterly Report.

    ERIC Educational Resources Information Center

    Pollard, Jim

    This report reviews software packages for Apple Macintosh and Apple II computers available to secondary schools to teach computer-aided drafting (CAD). Products for the report were gathered through reviews of CAD periodicals, computers in education periodicals, advertisements, and teacher recommendations. The first section lists the primary…

  3. Computer Aided Drafting Packages for Secondary Education. Edition 2. PC DOS Compatible Programs. A MicroSIFT Quarterly Report.

    ERIC Educational Resources Information Center

    Pollard, Jim

    This report reviews eight IBM-compatible software packages that are available to secondary schools to teach computer-aided drafting (CAD). Software packages to be considered were selected following reviews of CAD periodicals, computers in education periodicals, advertisements, and recommendations of teachers. The packages were then rated by…

  4. A Comparison of the Effectiveness between Computer Aided Drafting and the Traditional Drafting Techniques as Methods of Teaching Pictorial and Multiview Drawings.

    ERIC Educational Resources Information Center

    Kashef, Ali E.

    A study was conducted to determine the effectiveness of teaching multiview and pictorial drawing using traditional methods and using computer-aided drafting (CAD). Research used a quasi-experimental design; subjects were 37 full- and part-time undergraduate students in industrial technology or technology education courses. The students were…

  5. Role of computer aided detection (CAD) integration: case study with meniscal and articular cartilage CAD applications

    NASA Astrophysics Data System (ADS)

    Safdar, Nabile; Ramakrishna, Bharath; Saiprasad, Ganesh; Siddiqui, Khan; Siegel, Eliot

    2008-03-01

    Knee-related injuries involving the meniscal or articular cartilage are common and require accurate diagnosis and surgical intervention when appropriate. With proper techniques and experience, confidence in detection of meniscal tears and articular cartilage abnormalities can be quite high. However, for radiologists without musculoskeletal training, diagnosis of such abnormalities can be challenging. In this paper, the potential of improving diagnosis through integration of computer-aided detection (CAD) algorithms for automatic detection of meniscal tears and articular cartilage injuries of the knees is studied. An integrated approach in which the results of algorithms evaluating either meniscal tears or articular cartilage injuries provide feedback to each other is believed to improve the diagnostic accuracy of the individual CAD algorithms due to the known association between abnormalities in these distinct anatomic structures. The correlation between meniscal tears and articular cartilage injuries is exploited to improve the final diagnostic results of the individual algorithms. Preliminary results from the integrated application are encouraging and more comprehensive tests are being planned.

  6. School District Uses Computer Aided Design and Drafting.

    ERIC Educational Resources Information Center

    Lorentz, Gordon S.

    1988-01-01

    Computer Aided Design and Drafting (CADD) programs are used to teach drafting at an Indiana high school. The school system's maintenance department shared use of the software and equipment to produce original drawings of school buildings. (MLF)

  7. The Effects of Cooperative and Individualistic Learning Structures on Achievement in a College-Level Computer-Aided Drafting Course

    ERIC Educational Resources Information Center

    Swab, A. Geoffrey

    2012-01-01

    This study of cooperative learning in post-secondary engineering education investigated achievement of engineering students enrolled in two intact sections of a computer-aided drafting (CAD) course. Quasi-experimental and qualitative methods were employed in comparing student achievement resulting from out-of-class cooperative and individualistic…

  8. Creation of Anatomically Accurate Computer-Aided Design (CAD) Solid Models from Medical Images

    NASA Technical Reports Server (NTRS)

    Stewart, John E.; Graham, R. Scott; Samareh, Jamshid A.; Oberlander, Eric J.; Broaddus, William C.

    1999-01-01

    Most surgical instrumentation and implants used in the world today are designed with sophisticated Computer-Aided Design (CAD)/Computer-Aided Manufacturing (CAM) software. This software automates the mechanical development of a product from its conceptual design through manufacturing. CAD software also provides a means of manipulating solid models prior to Finite Element Modeling (FEM). Few surgical products are designed in conjunction with accurate CAD models of human anatomy because of the difficulty with which these models are created. We have developed a novel technique that creates anatomically accurate, patient specific CAD solids from medical images in a matter of minutes.

  9. Producing geological illustrations using pc-based computer-aided drafting

    NASA Astrophysics Data System (ADS)

    Cameron, Kenneth L.; Cameron, Debra D.; Kelleher, Patrick C.

    Computer-aided drafting (CAD) software for IBM-compatible personal computers now has the power to produce complex illustrations such as geologic maps. Applications programs can be written that automate repetitive drafting tasks; nevertheless, it may take as long to enter the illustration in the computer as it would take to draft by hand. Once entered, however, the time required to edit and update the illustration may be reduced greatly compared to traditional methods. In addition, maps and other illustrations can be plotted at practically any scale with information shown appropriate for that scale. Areas can be "windowed" and plotted individually, and combinations of data (layers) can be plotted to produce a variety of illustrations from a single drawing file. The quality of the final product can equal or exceed that of traditional drafting. Beyond these basic applications, CAD software can perform graphics-related tasks that would otherwise be difficult or impossible. Such tasks include manipulating USGS digital maps, and interfacing with large textual databases to form geographic information systems.

  10. Surgical retained foreign object (RFO) prevention by computer aided detection (CAD)

    NASA Astrophysics Data System (ADS)

    Marentis, Theodore C.; Hadjiiyski, Lubomir; Chaudhury, Amrita R.; Rondon, Lucas; Chronis, Nikolaos; Chan, Heang-Ping

    2014-03-01

    Surgical Retained Foreign Objects (RFOs) cause significant morbidity and mortality. They are associated with $1.5 billion annually in preventable medical costs. The detection accuracy of radiographs for RFOs is a mediocre 59%. We address the RFO problem with two complementary technologies: a three dimensional (3D) Gossypiboma Micro Tag (μTa) that improves the visibility of RFOs on radiographs, and a Computer Aided Detection (CAD) system that detects the μTag. The 3D geometry of the μTag produces a similar 2D depiction on radiographs regardless of its orientation in the human body and ensures accurate detection by a radiologist and the CAD. We create a database of cadaveric radiographs with the μTag and other common man-made objects positioned randomly. We develop the CAD modules that include preprocessing, μTag enhancement, labeling, segmentation, feature analysis, classification and detection. The CAD can operate in a high specificity mode for the surgeon to allow for seamless workflow integration and function as a first reader. The CAD can also operate in a high sensitivity mode for the radiologist to ensure accurate detection. On a data set of 346 cadaveric radiographs, the CAD system performed at a high specificity (85.5% sensitivity, 0.02 FPs/image) for the OR and a high sensitivity (96% sensitivity, 0.73 FPs/image) for the radiologists.

  11. PROGRAMMING EXERCISES FOR COMPUTER AIDED DRAFTING (TITLE SUPPLIED).

    ERIC Educational Resources Information Center

    Miami-Dade Junior Coll., FL.

    REFERENCE MATERIAL AND PROGRAMING EXERCISES USED FOR THE COMPUTER AIDED DRAFTING SUMMER INSTITUTE AT MIAMI-DADE JUNIOR COLLEGE, JULY 10-28, 1967, ARE PRESENTED. THE EXERCISES, TO BE PROGRAMED FOR EXECUTION ON THE IBM SYSTEM 1620 WITH AN ON-LINE 1627 PLOTTER, PROVIDE A MEDIUM FOR COVERING AND ENFORCING THE SUBJECT MATERIAL. ALSO INCLUDED ARE (1)…

  12. National Occupational Skill Standards. CADD: Computer Aided Drafting and Design.

    ERIC Educational Resources Information Center

    National Coalition for Advanced Manufacturing, Washington, DC.

    This document identifies computer-aided drafting and design (CADD) skills that companies require of training programs and future employees. The information was developed by two committees of technically knowledgeable CADD users from across the United States and validated by several hundred other CADD users. The skills are aimed at a beginner CADD…

  13. An Analysis of Computer Aided Design (CAD) Packages Used at MSFC for the Recent Initiative to Integrate Engineering Activities

    NASA Technical Reports Server (NTRS)

    Smith, Leigh M.; Parker, Nelson C. (Technical Monitor)

    2002-01-01

    This paper analyzes the use of Computer Aided Design (CAD) packages at NASA's Marshall Space Flight Center (MSFC). It examines the effectiveness of recent efforts to standardize CAD practices across MSFC engineering activities. An assessment of the roles played by management, designers, analysts, and manufacturers in this initiative will be explored. Finally, solutions are presented for better integration of CAD across MSFC in the future.

  14. Computer Aided Detection (CAD) Systems for Mammography and the Use of GRID in Medicine

    NASA Astrophysics Data System (ADS)

    Lauria, Adele

    It is well known that the most effective way to defeat breast cancer is early detection, as surgery and medical therapies are more efficient when the disease is diagnosed at an early stage. The principal diagnostic technique for breast cancer detection is X-ray mammography. Screening programs have been introduced in many European countries to invite women to have periodic radiological breast examinations. In such screenings, radiologists are often required to examine large numbers of mammograms with a double reading, that is, two radiologists examine the images independently and then compare their results. In this way an increment in sensitivity (the rate of correctly identified images with a lesion) of up to 15% is obtained.1,2 In most radiological centres, it is a rarity to find two radiologists to examine each report. In recent years different Computer Aided Detection (CAD) systems have been developed as a support to radiologists working in mammography: one may hope that the "second opinion" provided by CAD might represent a lower cost alternative to improve the diagnosis. At present, four CAD systems have obtained the FDA approval in the USA. † Studies3,4 show an increment in sensitivity when CAD systems are used. Freer and Ulissey in 2001 5 demonstrated that the use of a commercial CAD system (ImageChecker M1000, R2 Technology) increases the number of cancers detected up to 19.5% with little increment in recall rate. Ciatto et al.,5 in a study simulating a double reading with a commercial CAD system (SecondLook‡), showed a moderate increment in sensitivity while reducing specificity (the rate of correctly identified images without a lesion). Notwithstanding these optimistic results, there is an ongoing debate to define the advantages of the use of CAD as second reader: the main limits underlined, e.g., by Nishikawa6 are that retrospective studies are considered much too optimistic and that clinical studies must be performed to demonstrate a statistically

  15. Computer-aided determination of occlusal contact points for dental 3-D CAD.

    PubMed

    Maruyama, Tomoaki; Nakamura, Yasuo; Hayashi, Toyohiko; Kato, Kazumasa

    2006-05-01

    Present dental CAD systems enable us to design functional occlusal tooth surfaces which harmonize with the patient's stomatognathic function. In order to avoid occlusal interferences during tooth excursions, currently available systems usually use the patient's functional occlusal impressions for the design of occlusal contact points. Previous interfere-free design, however, has been done on a trial-and-error basis by using visual inspection. To improve this time-consuming procedure, this paper proposes a computer-aided system for assisting in the determination of the occlusal contact points by visualizing the appropriate regions of the opposing surface. The system can designate such regions from data of the opposing occlusal surfaces and their relative movements can be simulated by using a virtual articulator. Experiments for designing the crown of a lower first molar demonstrated that all contact points selected within the designated regions completely satisfied the required contact or separation during tooth excursions, confirming the effectiveness of our computer-aided procedure.

  16. Computer-aided design and computer-aided manufacture (CAD/CAM) system for construction of spinal orthosis for patients with adolescent idiopathic scoliosis.

    PubMed

    Wong, M S

    2011-01-01

    ABSTRACT Spinal orthoses are commonly prescribed to patients with moderate adolescent idiopathic scoliosis (AIS) for prevention of further curve deterioration. In conventional manufacturing method, plaster bandages are used to obtain the patient's body contour and then the plaster cast is rectified manually. With computer-aided design and computer-aided manufacture (CAD/CAM) system, a series of automated processes from body scanning to digital rectification and milling of the positive model can be performed in a fast and accurate fashion. The purpose of this manuscript is to introduce the application of CAD/CAM system to the construction of spinal orthosis for patients with AIS. Based on evidence within the literature, CAD/CAM method can achieve similar clinical outcomes but with higher efficiency than the conventional fabrication method. Therefore, CAD/CAM method should be considered a substitute to the conventional method in fabrication of spinal orthoses for patients with AIS.

  17. Train effectively for CAD/D

    SciTech Connect

    Not Available

    1983-04-01

    After failing with an unstructured computer-aided drafting/ design CAD/D program, Bechtel changed to a structured training program. Five considerations are presented here: teach CAD/D to engineers, not engineering to CAD/D experts; keep the program flexible enough to avoid rewriting due to fast technology evolution; pace information delivery; and rote learning of sequences only works if the students have a conceptual model first. On the job training is necessary, and better monitoring systems to test the OJT are needed. One such test is presented.

  18. Computer Use and CAD in Assisting Schools in the Creation of Facilities.

    ERIC Educational Resources Information Center

    Beach, Robert H.; Essex, Nathan

    1987-01-01

    Computer-aided design (CAD) programs are powerful drafting tools, but are also able to assist with many other facility planning functions. Describes the hardware, software, and the learning process that led to understanding the CAD software at the University of Alabama. (MLF)

  19. Computer-Aided Design/Manufacturing (CAD/M) for high-speed interconnect

    NASA Astrophysics Data System (ADS)

    Santoski, N. F.

    1981-10-01

    The objective of the Computer-Aided Design/Manufacturing (CAD/M) for High-Speed Interconnect Program study was to assess techniques for design, analysis and fabrication of interconnect structures between high-speed logic ICs that are clocked in the 200 MHz to 5 GHz range. Interconnect structure models were investigated and integrated with existing device models. Design rules for interconnects were developed in terms of parameters that can be installed in software that is used for the design, analysis and fabrication of circuits. To implement these design rules in future software development, algorithms and software development techniques were defined. Major emphasis was on Printed Wiring Board and hybrid level circuits as opposed to monolithic chips. Various packaging schemes were considered, including controlled impedance lines in the 50 to 200 ohms range where needed. The design rules developed are generic in nature, in that various architecture classes and device technologies were considered.

  20. Teaching Drafting 101: What Comes First?

    ERIC Educational Resources Information Center

    Carkhuff, Don

    2006-01-01

    Employers require pristine drawings that convey clarity and precision for the production of goods. Can a change in sequence of instruction be expeditious and help teachers better prepare their students for the workplace? Research suggests that combining traditional drafting and computer-aided drafting (CAD) instruction makes sense. It is analogous…

  1. Can computer-aided diagnosis (CAD) help radiologists find mammographically missed screening cancers?

    NASA Astrophysics Data System (ADS)

    Nishikawa, Robert M.; Giger, Maryellen L.; Schmidt, Robert A.; Papaioannou, John

    2001-06-01

    We present data from a pilot observer study whose goal is design a study to test the hypothesis that computer-aided diagnosis (CAD) can improve radiologists' performance in reading screening mammograms. In a prospective evaluation of our computer detection schemes, we have analyzed over 12,000 clinical exams. Retrospective review of the negative screening mammograms for all cancer cases found an indication of the cancer in 23 of these negative cases. The computer found 54% of these in our prospective testing. We added to these cases normal exams to create a dataset of 75 cases. Four radiologists experienced in mammography read the cases and gave their BI-RADS assessment and their confidence that the patient should be called back for diagnostic mammography. They did so once reading the films only and a second time reading with the computer aid. Three radiologists had no change in area under the ROC curve (mean Az of 0.73) and one improved from 0.73 to 0.78, but this difference failed to reach statistical significance (p equals 0.23). These data are being used to plan a larger more powerful study.

  2. Using Claris CAD To Develop a Floor Plan. High-Technology Training Module.

    ERIC Educational Resources Information Center

    Pawlowicz, Bruce; Johnson, Tom

    This learning module for a high school architectural drafting course introduces students to the use of Claris CAD (Computer Aided Drafting) to develop a floor plan. The six sections of the module are the following: module objectives, content outline, teaching methods, student activities, resource list, and evaluation (pretest, posttest). Student…

  3. CAD: Designs on Business.

    ERIC Educational Resources Information Center

    Milburn, Ken

    1988-01-01

    Provides a general review of the field of Computer-Aided Design Software including specific reviews of "Autosketch,""Generic CADD,""Drafix 1 Plus,""FastCAD," and "Autocad Release 9." Brief articles include "Blueprint for Generation,""CAD for Every Department,""Ideas Sketched in Glass,""CAD on the MAC," and "A CAD Package Sampler." (CW)

  4. Use of computer aided drafting for analysis and control of posture in manual work.

    PubMed

    Ulin, S S; Armstrong, T J; Radwin, R G

    1990-06-01

    Computer aided design (CAD) in conjunction with digitised anthropometric manikins can be used for analysis and control of stressful work postures, one of the most frequently cited occupational risk factors of upper extremity cumulative trauma disorders. This paper describes the use of macros for manipulating manikins and workstation components and for designing the workplace. AutoCAD, a popular computer aided design software package, was used to demonstrate the feasibility of these concepts. Specifically, macros are used for drawing work equipment using parametric designs, manipulating manikins and analysing jobs. In comparing the macros to the use of primitive CAD commands, the macros not only decrease the amount of time needed to create workstation components, but they also make the task easier for the user and decrease the risk of errors. Despite the limitation of anthropometric data and manikins, CAD is an effective method for identifying postural stresses and redesigning the workstation to control the identified stresses. PMID:15676770

  5. 78 FR 66940 - Regulatory Requirements for Hearing Aid Devices and Personal Sound Amplification Products; Draft...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-07

    ... implemented to promote the prompt diagnosis of treatable medical conditions causing hearing loss. To ensure... HUMAN SERVICES Food and Drug Administration Regulatory Requirements for Hearing Aid Devices and Personal... Hearing Aid Devices and Personal Sound Amplification Products.'' This draft guidance clarifies...

  6. CAD/CAM/CNC.

    ERIC Educational Resources Information Center

    Domermuth, Dave; And Others

    1996-01-01

    Includes "Quick Start CNC (computer numerical control) with a Vacuum Filter and Laminated Plastic" (Domermuth); "School and Industry Cooperate for Mutual Benefit" (Buckler); and "CAD (computer-assisted drafting) Careers--What Professionals Have to Say" (Skinner). (JOW)

  7. Teaching for CAD Expertise

    ERIC Educational Resources Information Center

    Chester, Ivan

    2007-01-01

    CAD (Computer Aided Design) has now become an integral part of Technology Education. The recent introduction of highly sophisticated, low-cost CAD software and CAM hardware capable of running on desktop computers has accelerated this trend. There is now quite widespread introduction of solid modeling CAD software into secondary schools but how…

  8. CAD in the processing plant environment or managing the CAD revolution

    SciTech Connect

    Woolbert, M.A.; Bennett, R.S.; Haring, W.I.

    1985-10-01

    The author presents a case report on the use of a Computer Aided Design/Computer Aided Drafting (CAD) system. Illustrated is a four-work station system, in addition to which there are two 70 megabyte disk drives, a check plotter and a 24-inch wide electrostatic plotter, a 300 megabyte disk for on-line storage, a tape drive for archive and backup, and a 1-megabyte network process server. It is a distributed logic system. The author states that the CAD system both inexpensive enough and powerful enough for the plant environment is relatively new on the market, made possible by the advent of super microcomputers. Also discussed is the impact the CAD system has had on productivity.

  9. CAD-CAM at Bendix Kansas city: the BICAM system

    SciTech Connect

    Witte, D.R.

    1983-04-01

    Bendix Kansas City Division (BEKC) has been involved in Computer Aided Manufacturing (CAM) technology since the late 1950's when the numerical control (N/C) analysts installed computers to aid in N/C tape preparation for numerically controlled machines. Computer Aided Design (CAD) technology was introduced in 1976, when a number of 2D turnkey drafting stations were procured for printed wiring board (PWB) drawing definition and maintenance. In June, 1980, CAD-CAM Operations was formed to incorporate an integrated CAD-CAM capability into Bendix operations. In March 1982, a ninth division was added to the existing eight divisions at Bendix. Computer Integrated Manufacturing (CIM) is a small organization, reporting directly to the general manager, who has responsibility to coordinate the overall integration of computer aided systems at Bendix. As a long range plan, CIM has adopted a National Bureau of Standards (NBS) architecture titled Factory of the Future. Conceptually, the Bendix CAD-CAM system has a centrally located data base which can be accessed by both CAD and CAM tools, processes, and personnel thus forming an integrated Computer Aided Engineering (CAE) System. This is a key requirement of the Bendix CAD-CAM system that will be presented in more detail.

  10. The state of PC-based CADD (computer-aided design and drafting) systems

    SciTech Connect

    Brandt, G.L.; Bowers, J.M.; Gorman, T.S.; Taylor, L.E.

    1988-07-11

    This report provides an overview of the state of the art of personal computer (PC)-based computer-aided design and drafting (CADD) systems for mechanical engineering applications. It presents the results of an evaluation performed on seven systems during October 1987 to March 1988 and summarizes the strengths and weaknesses of the systems.

  11. Operation of a computer aided drafting system: improvements, results and hopes

    SciTech Connect

    Millaud, J.; Goulding, F.; Salz, P.; Shimada, K.

    1983-10-01

    A two workstation Computer Aided Drafting system has been in operation since September 1982 at the Lawrence Berkeley Laboratory, Department of Instrument Science and Engineering. Improvements made to the original hardware and software configuration are described. Benefits from this installation are reported and future developments are outlined.

  12. Improving radiation survey data using CADD/CAE (computer-aided design and drafting computer-aided engineering)

    SciTech Connect

    Palau, G.L.; Tarpinian, J.E.

    1987-01-01

    A new application of computer-aided design and drafting (CADD) and computer-aided engineering (CAE) at the Three Mile Island Unit 2 (TMI-2) cleanup is improving the quality of radiation survey data taken in the plant. The use of CADD/CAE-generated survey maps has increased both the accuracy of survey data and the capability to perform analyses with these data. In addition, health physics technician manhours and radiation exposure can be reduced in situations where the CADD/CAE-generated drawings are used for survey mapping.

  13. CAD/CAM (Computer Aided Design/Computer Aided Manufacture). A Brief Guide to Materials in the Library of Congress.

    ERIC Educational Resources Information Center

    Havas, George D.

    This brief guide to materials in the Library of Congress (LC) on computer aided design and/or computer aided manufacturing lists reference materials and other information sources under 13 headings: (1) brief introductions; (2) LC subject headings used for such materials; (3) textbooks; (4) additional titles; (5) glossaries and handbooks; (6)…

  14. Catheter detection and classification on chest radiographs: an automated prototype computer-aided detection (CAD) system for radiologists

    NASA Astrophysics Data System (ADS)

    Ramakrishna, Bharath; Brown, Matthew; Goldin, Jonathan; Cagnon, Chris; Enzmann, Dieter

    2011-03-01

    Chest radiographs are the quickest and safest method to check placement of man-made medical devices placed in the body like catheters, stents and pacemakers etc out of which catheters are the most commonly used devices. The two most often used catheters especially in the ICU are the Endotracheal (ET) tube used to maintain patient's airway and the Nasogastric (NG) tube used to feed and administer drugs. Tertiary ICU's typically generate over 250 chest radiographs per day to confirm tube placement. Incorrect tube placements can cause serious complications and can even be fatal. The task of identifying these tubes on chest radiographs is difficult for radiologists and ICU personnel given the high volume of cases. This motivates the need for an automatic detection system to aid radiologists in processing these critical cases in a timely fashion while maintaining patient safety. To-date there has been very little research in this area. This paper develops a new fully automatic prototype computer-aided detection (CAD) system for detection and classification of catheters on chest radiographs using a combination of template matching, morphological processing and region growing. The preliminary evaluation was carried out on 25 cases. The prototype CAD system was able to detect ET and NG tubes with sensitivities of 73.7% and 76.5% respectively and with specificities of 91.3% and 84.0% respectively. The results from the prototype system show that it is feasible to automatically detect both catheters on chest radiographs, with the potential to significantly speed the delivery of imaging services while maintaining high accuracy.

  15. Using the Continuum of Design Modelling Techniques to Aid the Development of CAD Modeling Skills in First Year Industrial Design Students

    ERIC Educational Resources Information Center

    Storer, I. J.; Campbell, R. I.

    2012-01-01

    Industrial Designers need to understand and command a number of modelling techniques to communicate their ideas to themselves and others. Verbal explanations, sketches, engineering drawings, computer aided design (CAD) models and physical prototypes are the most commonly used communication techniques. Within design, unlike some disciplines,…

  16. Classroom Experiences in an Engineering Design Graphics Course with a CAD/CAM Extension.

    ERIC Educational Resources Information Center

    Barr, Ronald E.; Juricic, Davor

    1997-01-01

    Reports on the development of a new CAD/CAM laboratory experience for an Engineering Design Graphics (EDG) course. The EDG curriculum included freehand sketching, introduction to Computer-Aided Design and Drafting (CADD), and emphasized 3-D solid modeling. Reviews the project and reports on the testing of the new laboratory components which were…

  17. Using a computer-aided drafting system to aid in engineering and fabrication

    NASA Astrophysics Data System (ADS)

    Millaud, J.; Goulding, F.; Salz, P.

    1985-05-01

    The generation of schematics and artwork on CAD workstations yields a large amount of numeric data that can be used in many ways. Standard by-products are connection lists, photoplot files and drill files. Using open-ended software allows for more information to be retrieved and used for various purposes in engineering and fabrication.

  18. Improvement of MS (multiple sclerosis) CAD (computer aided diagnosis) performance using C/C++ and computing engine in the graphical processing unit (GPU)

    NASA Astrophysics Data System (ADS)

    Suh, Joohyung; Ma, Kevin; Le, Anh

    2011-03-01

    Multiple Sclerosis (MS) is a disease which is caused by damaged myelin around axons of the brain and spinal cord. Currently, MR Imaging is used for diagnosis, but it is very highly variable and time-consuming since the lesion detection and estimation of lesion volume are performed manually. For this reason, we developed a CAD (Computer Aided Diagnosis) system which would assist segmentation of MS to facilitate physician's diagnosis. The MS CAD system utilizes K-NN (k-nearest neighbor) algorithm to detect and segment the lesion volume in an area based on the voxel. The prototype MS CAD system was developed under the MATLAB environment. Currently, the MS CAD system consumes a huge amount of time to process data. In this paper we will present the development of a second version of MS CAD system which has been converted into C/C++ in order to take advantage of the GPU (Graphical Processing Unit) which will provide parallel computation. With the realization of C/C++ and utilizing the GPU, we expect to cut running time drastically. The paper investigates the conversion from MATLAB to C/C++ and the utilization of a high-end GPU for parallel computing of data to improve algorithm performance of MS CAD.

  19. Computer-aided design and drafting visualization of anatomical structure of the human eye and orbit

    NASA Astrophysics Data System (ADS)

    Parshall, Robert F.; Sadler, Lewis L.

    1991-04-01

    A generalized " anatomically standard" eyeball was geometrically modeled on a Computer-Aided Design and Drafting (CADD) workstation based on published conceptual norms of dimension radii of curvature alignments etc. An orbital environment for this model was concurrently prepared by serial section reconstruction of a cadaver specimen. Issues addressed include orienting unregistered sections the utility of interactive CADDsupported visual logic in interpretive decision making and the value of geometric models.

  20. Gathering Empirical Evidence Concerning Links between Computer Aided Design (CAD) and Creativity

    ERIC Educational Resources Information Center

    Musta'amal, Aede Hatib; Norman, Eddie; Hodgson, Tony

    2009-01-01

    Discussion is often reported concerning potential links between computer-aided designing and creativity, but there is a lack of systematic enquiry to gather empirical evidence concerning such links. This paper reports an indication of findings from other research studies carried out in contexts beyond general education that have sought evidence…

  1. Getting into CAD at the Savannah River Plant

    SciTech Connect

    Scoggins, W.R.

    1984-01-01

    In 1978, the Savannah River Plant (SRP) Project Department was producing approximately 1100 new drawings and 3000 revisions per year, with a force of 30 draftsmen. Design services for the Plant were increasing due to changing programs, obsolescent equipment replacements and added security requirements. This increasing workload greatly increased the engineering drafting backlog. At the same time, many draftsmen were approaching retirement age and were to be replaced with unskilled draftsman trainees. A proposal was presented to management to acquire a Computer Aided Drafting (CAD) system to produce instrument and electrical drawings which comprised 30% of the work load.

  2. Comparison of standard and double reading and computer-aided detection (CAD) of interval cancers at prior negative screening mammograms: blind review.

    PubMed

    Ciatto, S; Rosselli Del Turco, M; Burke, P; Visioli, C; Paci, E; Zappa, M

    2003-11-01

    The study evaluates the role of computer-aided detection (CAD) in improving the detection of interval cancers as compared to conventional single (CONV) or double reading (DOUBLE). With this purpose, a set of 89 negative cases was seeded with 31 mammograms reported as negative and developing interval cancer in the following 2-year interval (false negative (FN)=11, minimal signs (MS)=20). A total of radiologists read the set with CONV and then with CAD. Overall, there were 589 cancer and 1691 noncancer readings with both CONV and CAD. Double reading was simulated by combining conventional readings in all 171 possible combinations of 19 radiologists, resulting in a total of 5301 cancer and 15 219 noncancer readings. Conventional single, DOUBLE and CAD readings were compared in terms of sensitivity and recall rate. Considering all 19 readings, cancer was identified in 190 or 248 of 589 readings (32.2 vs 42.1%, chi(2)=11.80, df=1, P<0.01) and recalls were 287 or 405 of 1691 readings (16.9 vs 23.9%, chi(2)=24.87, df=1, P<0.01) at CONV or CAD, respectively. When considering FN and MS cases separately, sensitivity at CONV or CAD was 50.2 or 62.6% (chi(2)=6.98, df=1, P=0.01) for FN and 22.3 or 30.7% (chi(2)=6.47, df=1, P=0.01) for MS cases, respectively. Computer-aided detection (average of 19 readings) was slightly and not significantly less sensitive (sensitivity: 42.1 vs 46.1%, chi(2)=3.24, df=1, P=0.07) but more specific (recall rate 23.9 vs 26.1%, chi(2)=3.8, df=1, P=0.04) as compared to DOUBLE (average of 171 readings). Average sensitivity for FN cases only was 62.6% for CAD and 64.8% for DOUBLE (chi(2)=0.32, df=1, P=0.58). Corresponding values for MS cases were 30.7% for CAD and 35.7% for DOUBLE (chi(2)=3.53, df=1, P=0.06). Compared to CONV, CAD allowed for improved sensitivity, though with reduced specificity, both effects being statistically significant. Computer-aided detection was almost as sensitive as DOUBLE but significantly more specific. Computer-aided

  3. Development of problem-oriented software packages for numerical studies and computer-aided design (CAD) of gyrotrons

    NASA Astrophysics Data System (ADS)

    Damyanova, M.; Sabchevski, S.; Zhelyazkov, I.; Vasileva, E.; Balabanova, E.; Dankov, P.; Malinov, P.

    2016-03-01

    Gyrotrons are the most powerful sources of coherent CW (continuous wave) radiation in the frequency range situated between the long-wavelength edge of the infrared light (far-infrared region) and the microwaves, i.e., in the region of the electromagnetic spectrum which is usually called the THz-gap (or T-gap), since the output power of other devices (e.g., solid-state oscillators) operating in this interval is by several orders of magnitude lower. In the recent years, the unique capabilities of the sub-THz and THz gyrotrons have opened the road to many novel and future prospective applications in various physical studies and advanced high-power terahertz technologies. In this paper, we present the current status and functionality of the problem-oriented software packages (most notably GYROSIM and GYREOSS) used for numerical studies, computer-aided design (CAD) and optimization of gyrotrons for diverse applications. They consist of a hierarchy of codes specialized to modelling and simulation of different subsystems of the gyrotrons (EOS, resonant cavity, etc.) and are based on adequate physical models, efficient numerical methods and algorithms.

  4. An Investigation into Computer Aided Drafting and Design (CADD) in the Saginaw Area from the Viewpoint of Mechanical Drafting and Design Employers.

    ERIC Educational Resources Information Center

    Irwin, John L.

    The extent to which computer-aided drafting and design (CADD) was being used in local businesses in Saginaw, Michigan, was investigated. Focuses of a literature review were types of CADD systems, categories of CADD users, and the symbiotic relationship between industry and education in providing CADD training. The survey questionnaire was…

  5. Comparison of Conventional and Computer-Aided Drafting Methods from the View of Time and Drafting Quality

    ERIC Educational Resources Information Center

    Ozkan, Aysen; Yildirim, Kemal

    2016-01-01

    Problem Statement: Drafting course is essential for students in the design disciplines for becoming more organized and for complying with standards in the educational system. Drafting knowledge is crucial, both for comprehension of the issues and for the implementation phase. In any design project, drafting performance and success are as important…

  6. Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography

    PubMed Central

    Prakashini, K; Babu, Satish; Rajgopal, KV; Kokila, K Raja

    2016-01-01

    Aims and Objectives: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. Materials and Methods: A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Observations and Results: Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4–10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. Conclusion: CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time. PMID:27578931

  7. CAD/CAE Integration Enhanced by New CAD Services Standard

    NASA Technical Reports Server (NTRS)

    Claus, Russell W.

    2002-01-01

    A Government-industry team led by the NASA Glenn Research Center has developed a computer interface standard for accessing data from computer-aided design (CAD) systems. The Object Management Group, an international computer standards organization, has adopted this CAD services standard. The new standard allows software (e.g., computer-aided engineering (CAE) and computer-aided manufacturing software to access multiple CAD systems through one programming interface. The interface is built on top of a distributed computing system called the Common Object Request Broker Architecture (CORBA). CORBA allows the CAD services software to operate in a distributed, heterogeneous computing environment.

  8. Evaluation of computer-aided design and drafting for the electric power industry. Final report

    SciTech Connect

    Anuskiewicz, T.; Barduhn, G.; Lowther, B.; Osman, I.

    1984-01-01

    This report reviews current and future computer-aided design and drafting (CADD) technology relative to utility needs and to identify useful development projects that may be undertaken by EPRI. The principal conclusions are that computer aids offer substantial cost and time savings and that computer systems are being developed to take advantage of the savings. Data bases are not available for direct communication between computers used by the power industry and will limit benefits to the industry. Recommendations are made for EPRI to take the initiative to develop the data bases for direct communication between power industry computers and to research, develop, and demonstrate new applications within the industry. Key components of a CADD system are described. The state of the art of two- and three-dimensional CADD systems to perform graphics and project management control functions are assessed. Comparison is made of three-dimensional electronic models and plastic models.

  9. Computer-aided detection of lung cancer on chest radiographs: effect of machine CAD true positive/false negative detections on radiologists' confidence level

    NASA Astrophysics Data System (ADS)

    Freedman, Matthew T.; Osicka, Teresa; Lo, Shih-Chung Benedict; Lure, Fleming; Xu, Xin-Wei; Lin, Jesse; Zhao, Hui; Zhang, Ron

    2004-05-01

    This paper evaluates the effect of Computer-Aided Detection prompts on the confidence and detection of cancer on chest radiographs. Expected findings included an increase in confidence rating and a decrease in variance in confidence when radiologists interacted with a computer prompt that confirmed their initial decision or induced them to switch from an incorrect to a correct decision. Their confidence rating decreased and the variance of confidence rating increased when the computer failed to confirm a correct or incorrect decision. A population of cases was identified that changed among reading modalities. This unstable group of cases differed between the Independent and Sequential without CAD modalities in cancer detection by radiologists and cancer detection by machine. CAD prompts induced the radiologists to make two types of changes in cases: changes on the sequential modality with CAD that restored an initial diagnosis made in the Independent read and new changes that were not present in the Independent or Sequential reads without CAD. This has implications for double reading of cases. The effects of intra-observer variability and inter-observer variability are suggested as potential causes for differences in statistical significance of the Independent and Sequential Design approaches to ROC studies.

  10. CAD programs: a tool for crime scene processing and reconstruction

    NASA Astrophysics Data System (ADS)

    Boggiano, Daniel; De Forest, Peter R.; Sheehan, Francis X.

    1997-02-01

    Computer aided drafting (CAD) programs have great potential for helping the forensic scientist. One of their most direct and useful applications is crime scene documentation, as an aid in rendering neat, unambiguous line drawings of crime scenes. Once the data has been entered, it can easily be displayed, printed, or plotted in a variety of formats. Final renditions from this initial data entry can take multiple forms and can have multiple uses. As a demonstrative aid, a CAD program can produce two dimensional (2-D) drawings of the scene from one's notes to scale. These 2-D renditions are court display quality and help to make the forensic scientists's testimony easily understood. Another use for CAD is as an analytical tool for scene reconstruction. More than just a drawing aid, CAD can generate useful information from the data input. It can help reconstruct bullet paths or locations of furniture in a room when it is critical to the reconstruction. Data entry at the scene, on a notebook computer, can assist in framing and answering questions so that the forensic scientist can test hypotheses while actively documenting the scene. Further, three dimensional (3-D) renditions of items can be viewed from many 'locations' by using the program to rotate the object and the observers' viewpoint.

  11. Improvements in computer-aided detection/computer-aided classification (CAD/CAC) of bottom mines through post analysis of a diverse set of very shallow water (VSW) environmental test data

    NASA Astrophysics Data System (ADS)

    Ciany, Charles M.; Zurawski, William C.

    2004-09-01

    In 1999 Raytheon adapted its shallow-water Side-Looking Sonar (SLS) Computer Aided Detection/Computer Aided Classification (CAD/CAC) algorithm to process side-scan sonar data obtained with the Woods Hole Oceanographic Institute's Remote Environmental Monitoring Units (REMUS) autonomous underwater vehicle (AUV). To date, Raytheon has demonstrated the ability to effectively execute mine-hunting missions with the REMUS vehicle through the fusion of its CAD/CAC algorithm with several other CAD/CAC algorithms to achieve low false alarm rates while maintaining a high probability of correct detection/classification. Mine-hunting in the very shallow water (VSW) environment poses a host of difficulties including such issues as: a higher incidence of man made clutter, significant interference due to biological sources (such as kelp or silt), the scouring of mines into the bottom, interference from surface/bottom bounce, and image distortion due to vehicle motion during image generation. These issues coupled with highly variable bottom conditions and small bottom targets make reliable hunting in the VSW environment very difficult. In order to be operationally viable, the individual CAD/CAC algorithms must demonstrate robustness over these very different mine-hunting environments. A higher normalized false alarm rate per algorithm is considered acceptable based on the false alarm reduction achieved through multi-algorithm fusion. Raytheon's recent CAD/CAC algorithm enhancements demonstrate a significant improvement in overall CAD/CAC performance across a diverse set of environments, from the relatively benign Gulf of Mexico environment to the more challenging areas off the coast of southern California containing significant biological and bottom clutter. The improvements are attributed to incorporating an image normalizer into the algorithm's pre-processing stage in conjunction with several other modifications. The algorithm enhancements resulted in an 11% increase in overall

  12. Evaluation of Five Microcomputer CAD Packages.

    ERIC Educational Resources Information Center

    Leach, James A.

    1987-01-01

    Discusses the similarities, differences, advanced features, applications and number of users of five microcomputer computer-aided design (CAD) packages. Included are: "AutoCAD (V.2.17)"; "CADKEY (V.2.0)"; "CADVANCE (V.1.0)"; "Super MicroCAD"; and "VersaCAD Advanced (V.4.00)." Describes the evaluation of the packages and makes recommendations for…

  13. Impact of computer-aided design and drafting on operator perceptions and performance intentions

    SciTech Connect

    Mandeville, D.E.

    1987-01-01

    The goal of the introduction of computer-aided design and drafting (CADD) technology is to improve engineering quantity and quality outcomes. What is not so obvious is that the manner in which the operator views the CADD job may affect these outcomes. The study found that: (1) the subjects hold job characteristic beliefs about their jobs that are similar to those held by individuals in related professional and technical positions in other organizations; (2) subjects in routine jobs who had little experience with CADD believe that the characteristics of the job with CADD will be less desirable than there present job utilizing manual drafting; however, experienced users believe that there is little difference; (3) the subjects performing technologically routine jobs indicate that quantity and quality of their jobs decreases with CADD, while holders of technologically nonroutine jobs indicate the opposite; (4) significant but weak relationships existed between job characteristic beliefs, attitudes, and job intentions; however, the model relationships and strengths varied when subgroups were analyzed; and (5) the correlation of social referent group beliefs with subject beliefs are significant but weak.

  14. Facility management of computer-aided design, drafting/manufacturing systems (CADD/M)

    SciTech Connect

    Norton, F.J.

    1980-09-23

    Interactive Computer-Aided Design Drafting/Manufacturing systems have been installed in thousands of companies, applying CADD/M capabilities to many applications. This has been done with varying degrees of success even among companies with identical applications. Investigation of individual companies reveals a gap between the capabilities of CADD/M systems and the actual usage by industry of those capabilities. This company usage often determines the degree of success or failure of an interactive graphics facility and is largely controlled by management. The responsibilities of the interactive graphics facility managemant team are explained in detail. Proper management of a CADD/M facility is more critical to the success or failure of the facility than any other factor.

  15. Cost justification for an interactive Computer-Aided Design Drafting/Manufacturing system

    SciTech Connect

    Norton, F.J.

    1980-09-23

    Many factors influence the capital investment decision. System costs and benefits are weighed by methods of financial analysis to determine the advisability of an investment. Capital, expense, and benefits as related to Interactive Computer-Aided Design Drafting/Manufacturing (CADD/M) Systems are discussed and model calculations are included. An example is treated by the simple payback method and the more sophisticated methods of Net Present Value (NPV) and Internal Rate of Return (IRR). The NPV and IRR approaches include in the calculation the time value of money and provide a sounder foundation on which to base the purchase decision. It is hoped that an understanding of these techniques by technical personnel will make an optimum system purchase more likely.

  16. Drafting.

    ERIC Educational Resources Information Center

    Hughes, Larry R.

    This guide to teaching drafting, one in a series of instructional materials for junior high industrial arts education, is designed to assist teachers as they plan and implement new courses of study and as they make revisions and improvements in existing courses in order to integrate classroom learning with real-life experiences. This drafting…

  17. CAD for small hydro projects

    SciTech Connect

    Bishop, N.A. Jr. )

    1994-04-01

    Over the past decade, computer-aided design (CAD) has become a practical and economical design tool. Today, specifying CAD hardware and software is relatively easy once you know what the design requirements are. But finding experienced CAD professionals is often more difficult. Most CAD users have only two or three years of design experience; more experienced design personnel are frequently not CAD literate. However, effective use of CAD can be the key to lowering design costs and improving design quality--a quest familiar to every manager and designer. By emphasizing computer-aided design literacy at all levels of the firm, a Canadian joint-venture company that specializes in engineering small hydroelectric projects has cut costs, become more productive and improved design quality. This article describes how they did it.

  18. Comparison of sensitivity and reading time for the use of computer-aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader.

    PubMed

    Beyer, F; Zierott, L; Fallenberg, E M; Juergens, K U; Stoeckel, J; Heindel, W; Wormanns, D

    2007-11-01

    The purpose of this study was to compare sensitivity for detection of pulmonary nodules in MDCT scans and reading time of radiologists when using CAD as the second reader (SR) respectively concurrent reader (CR). Four radiologists analyzed 50 chest MDCT scans chosen from clinical routine two times and marked all detected pulmonary nodules: first with CAD as CR (display of CAD results immediately in the reading session) and later (median 14 weeks) with CAD as SR (display of CAD markers after completion of first reading without CAD). A Siemens LungCAD prototype was used. Sensitivities for detection of nodules and reading times were recorded. Sensitivity of reading with CAD as SR was significantly higher than reading without CAD (p < 0.001) and CAD as CR (p < 0.001). For nodule size of 1.75 mm or above no significant sensitivity difference between CAD as CR and reading without CAD was observed; e.g., for nodules above 4 mm sensitivity was 68% without CAD, 68% with CAD as CR (p = 0.45) and 75% with CAD as SR (p < 0.001). Reading time was significantly shorter for CR (274 s) compared to reading without CAD (294 s; p = 0.04) and SR (337 s; p < 0.001). In our study CAD could either speed up reading of chest CT cases for pulmonary nodules without relevant loss of sensitivity when used as CR, or it increased sensitivity at the cost of longer reading times when used as SR.

  19. Selecting and implementing an interactive Computer Aided Design Drafting/Manufacturing (CADD/M) system

    SciTech Connect

    Norton, F.J.

    1980-09-23

    Success with Interactive Computer-Aided Design Drafting/Manufacturing (CADD/M) depends upon management, users, and the system itself. If you are in a design and drafting environment, the thought of acquiring a CADD/M system will probably occur to you sometime in the very near future - if it hasn't already. Convincing yourself and your management of the benefits of such systems is but the first step. Evaluating and selecting one particular type of CADD/M system can turn out to be a complicated undertaking - not to mention somewhat frustrating. Procedures for selecting and successfully implementing a CADD/M system are outlined. INITIAL PREPARATION examines the techniques used to evaluate CADD/M systems including formation of an evaluation team, and application analysis. GRAPHICS EVALUATION describes the methods that can be used to test a CADD/M system, including benchmark drawings and specifications, human engineering considerations, and other evaluation criteria and general system configurations are also discussed. COMPUTER SYSTEM EVALUATION examines other factors in systems selection: programming, communications, documentation, and service. SYSTEM STARTUP addresses site preparation, people preparation, system acceptance, and operator, designer/drafter selection. Finally, operator, designer/drafter TRAINING and SYSTEM MANAGEMENT are discussed. This systematic approach wil help those contemplating the acquisition of CADD/M systems for their activities and will help minimize unplanned events and problem areas.Advanced planning in these areas is needed to ensure successful implementation of a CADD/M system. This in turn will lead to considerable cost savings and schedule improvements for an entire project, from initial design to final production. These are ambitious goals but easily realized if a logical and rational plan is adopted in the same manner as that used in a typical development program.

  20. An overview of the computer aided design system for drafting at Sandia National Laboratories, Livermore

    SciTech Connect

    Koopmann, B.E.

    1988-08-01

    Sandia Laboratories Livermore is converting the existing Computervision CADS system to a new hardware and software platform. This report describes the final configuration (after the conversion is completed) and the individual units comparing the system. A background describing the evolution of CADS at SNLL is appended.

  1. Computer-aided design drafting/manufacturing (CADD/M) facility preparation

    SciTech Connect

    Norton, F.J.

    1980-09-23

    Computer-Aided Design, Drafting and Manufacturing (CADD/M) equipment requires careful facilities preparation before installation takes place. This paper presents what a company should consider to ensure a proper installation. This includes consideration of working conditions. To get the most out of the system, the operators must be provided with a relaxed, comfortable environment, free from noise and other distractions. Such things as temperature requirements, lighting, power, security and fire protection are discussed. Also, future expansion needs are considered so that major construction will not be required for future years. Advanced planning in these areas is needed to ensure successful implementation of a CADD/M system. This will lead to considerable cost savings, and in the long run, improve the scheduling for an entire project, from initial design to final production. This careful preparation will minimize unplanned events and problem areas. These are ambitious goals but easily realized if a logical and rational plan is adopted in the same manner as that used in a typical development program.

  2. Use of CADD (Computer Aided Drafting and Design) in a construction setting

    SciTech Connect

    Ketcham, D.L.

    1988-01-01

    At the outset of the design for the Defense Waste Processing Facility (DWPF) it was determined to complete over 70 percent of the more than 7000 drawings on a Computer Aided Drafting and Design (CADD) system. This ambitious goal required the development of an integrated data base for plant design software systems to service a multi-discipline, engineering and management environment for the complex one-of-a-kind mega project. The implementation involved extensive training, special accounting and security provisions to meet QA requirements. It was found to be effective to train engineers as well as operators so that technical personnel could have direct access to the drawing files. This was particularly useful when designing and laying out close tolerance equipment in remotely maintained cells where clearances are critical. It was also beneficial to have the terminals located in the same areas as the engineering staff. Background drawings were maintained by one discipline and used as a reference file by the other disciplines. This reduced the chances of interferences and insured that the latest revisions were in use. 2 figs.

  3. CAD systems simplify engineering drawings

    SciTech Connect

    Holt, J.

    1986-10-01

    Computer assisted drafting systems, with today's technology, provide high-quality, timely drawings that can be justified by the lower costs for the final product. The author describes Exxon Pipeline Co.'s experience in deciding on hardware and software for a CAD system installation and the benefits effected by this procedure and equipment.

  4. Competency Reference for Computer Assisted Drafting.

    ERIC Educational Resources Information Center

    Oregon State Dept. of Education, Salem. Div. of Vocational Technical Education.

    This guide, developed in Oregon, lists competencies essential for students in computer-assisted drafting (CAD). Competencies are organized in eight categories: computer hardware, file usage and manipulation, basic drafting techniques, mechanical drafting, specialty disciplines, three dimensional drawing/design, plotting/printing, and advanced CAD.…

  5. CAD/CAM. High-Technology Training Module.

    ERIC Educational Resources Information Center

    Zuleger, Robert

    This high technology training module is an advanced course on computer-assisted design/computer-assisted manufacturing (CAD/CAM) for grades 11 and 12. This unit, to be used with students in advanced drafting courses, introduces the concept of CAD/CAM. The content outline includes the following seven sections: (1) CAD/CAM software; (2) computer…

  6. Statistical-techniques-based computer-aided diagnosis (CAD) using texture feature analysis: application in computed tomography (CT) imaging to fatty liver disease

    NASA Astrophysics Data System (ADS)

    Chung, Woon-Kwan; Park, Hyong-Hu; Im, In-Chul; Lee, Jae-Seung; Goo, Eun-Hoe; Dong, Kyung-Rae

    2012-09-01

    This paper proposes a computer-aided diagnosis (CAD) system based on texture feature analysis and statistical wavelet transformation technology to diagnose fatty liver disease with computed tomography (CT) imaging. In the target image, a wavelet transformation was performed for each lesion area to set the region of analysis (ROA, window size: 50 × 50 pixels) and define the texture feature of a pixel. Based on the extracted texture feature values, six parameters (average gray level, average contrast, relative smoothness, skewness, uniformity, and entropy) were determined to calculate the recognition rate for a fatty liver. In addition, a multivariate analysis of the variance (MANOVA) method was used to perform a discriminant analysis to verify the significance of the extracted texture feature values and the recognition rate for a fatty liver. According to the results, each texture feature value was significant for a comparison of the recognition rate for a fatty liver ( p < 0.05). Furthermore, the F-value, which was used as a scale for the difference in recognition rates, was highest in the average gray level, relatively high in the skewness and the entropy, and relatively low in the uniformity, the relative smoothness and the average contrast. The recognition rate for a fatty liver had the same scale as that for the F-value, showing 100% (average gray level) at the maximum and 80% (average contrast) at the minimum. Therefore, the recognition rate is believed to be a useful clinical value for the automatic detection and computer-aided diagnosis (CAD) using the texture feature value. Nevertheless, further study on various diseases and singular diseases will be needed in the future.

  7. Application of Fisher fusion techniques to improve the individual performance of sonar computer-aided detection/computer-aided classification (CAD/CAC) algorithms

    NASA Astrophysics Data System (ADS)

    Ciany, Charles M.; Zurawski, William C.

    2009-05-01

    Raytheon has extensively processed high-resolution sidescan sonar images with its CAD/CAC algorithms to provide classification of targets in a variety of shallow underwater environments. The Raytheon CAD/CAC algorithm is based on non-linear image segmentation into highlight, shadow, and background regions, followed by extraction, association, and scoring of features from candidate highlight and shadow regions of interest (ROIs). The targets are classified by thresholding an overall classification score, which is formed by summing the individual feature scores. The algorithm performance is measured in terms of probability of correct classification as a function of false alarm rate, and is determined by both the choice of classification features and the manner in which the classifier rates and combines these features to form its overall score. In general, the algorithm performs very reliably against targets that exhibit "strong" highlight and shadow regions in the sonar image- i.e., both the highlight echo and its associated shadow region from the target are distinct relative to the ambient background. However, many real-world undersea environments can produce sonar images in which a significant percentage of the targets exhibit either "weak" highlight or shadow regions in the sonar image. The challenge of achieving robust performance in these environments has traditionally been addressed by modifying the individual feature scoring algorithms to optimize the separation between the corresponding highlight or shadow feature scores of targets and non-targets. This study examines an alternate approach that employs principles of Fisher fusion to determine a set of optimal weighting coefficients that are applied to the individual feature scores before summing to form the overall classification score. The results demonstrate improved performance of the CAD/CAC algorithm on at-sea data sets.

  8. IGIS (Interactive Geologic Interpretation System) computer-aided photogeologic mapping with image processing, graphics and CAD/CAM capabilities

    SciTech Connect

    McGuffie, B.A.; Johnson, L.F.; Alley, R.E.; Lang, H.R. )

    1989-10-01

    Advances in computer technology are changing the way geologists integrate and use data. Although many geoscience disciplines are absolutely dependent upon computer processing, photogeological and map interpretation computer procedures are just now being developed. Historically, geologists collected data in the field and mapped manually on a topographic map or aerial photographic base. New software called the interactive Geologic Interpretation System (IGIS) is being developed at the Jet Propulsion Laboratory (JPL) within the National Aeronautics and Space Administration (NASA)-funded Multispectral Analysis of Sedimentary Basins Project. To complement conventional geological mapping techniques, Landsat Thematic Mapper (TM) or other digital remote sensing image data and co-registered digital elevation data are combined using computer imaging, graphics, and CAD/CAM techniques to provide tools for photogeologic interpretation, strike/dip determination, cross section construction, stratigraphic section measurement, topographic slope measurement, terrain profile generation, rotatable 3-D block diagram generation, and seismic analysis.

  9. Traditional Engineering Graphics versus Computer-Aided Drafting: A View from Academe.

    ERIC Educational Resources Information Center

    Foster, Robert J.

    1987-01-01

    Argues for a legitimate role of manually expressed engineering graphics within engineering education as a needed support for computer-assisted drafting work. Discusses what and how students should learn as well as trends in engineering graphics education. Compares and contrasts manual and computer drafting methods. (CW)

  10. DOE data exchange format specification, mechanical products/drafting: Version 1. 3, CADCAM-045

    SciTech Connect

    Not Available

    1988-01-01

    The Data Exchange Format (DEF) has been developed as part of a Department of Energy (DOE) effort to integrate the Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) activities throughout the Nuclear Weapons Complex (NWC). A primary objective of this effort is to provide a capability for the exchange of digital data between dissimilar CAD/CAM systems within the NWC. This specification is the result of a collective effort of the DOE Data Exchange Format Group charged with the task of defining a subset of the Initial Graphics Exchange Specification (IGES) to be used as the data exchange format for the mechanical products/drafting application.

  11. DOE data exchange format specification, mechanical products/drafting: Version 1. 2. 2: CADCAM-045

    SciTech Connect

    Not Available

    1987-09-01

    The Data Exchange Format (DEF) has been developed as part of a Department of Energy (DOE) effort to integrate the Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) activities throughout the Nuclear Weapons Complex (NWC). A primary objective of this effort is to provide a capability for the exchange of digital data between dissimilar CAD/CAM systems within the NWC. This specification is the result of a collective effort of the DOE Data Exchange Format Group charged with the task of defining a subset of the Initial Graphics Exchange Specification (IGES) to be used as the data exchange format for the mechanical products/drafting application.

  12. The Drafting and Submission of an HIV/AIDS Policy Draft for a Native American Child Welfare Agency.

    ERIC Educational Resources Information Center

    Holzemer, Daniel Pete

    An Indian child welfare agency realized the need for an HIV/AIDS policy when a diabetic child possibly exposed to the HIV virus was placed in one of the agency's licensed foster homes. A focus-group interview process was selected for policy development because this method appeared to parallel the Native American cultural approach toward consensus…

  13. Comparison of sensitivity and reading time for the use of computer aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader

    NASA Astrophysics Data System (ADS)

    Beyer, F.; Zierott, L.; Fallenberg, E. M.; Juergens, K.; Stoeckel, J.; Heindel, W.; Wormanns, D.

    2006-03-01

    Purpose: To compare sensitivity and reading time when using CAD as second reader resp. concurrent reader. Materials and Methods: Fifty chest MDCT scans due to clinical indication were analysed independently by four radiologists two times: First with CAD as concurrent reader (display of CAD results simultaneously to the primary reading by the radiologist); then after a median of 14 weeks with CAD as second reader (CAD results were shown after completion of a reading session without CAD). A prototype version of Siemens LungCAD (Siemens,Malvern,USA) was used. Sensitivities and reading times for detecting nodules >=4mm of concurrent reading, reading without CAD and second reading were recorded. In a consensus conference false positive findings were eliminated. Student's T-Test was used to compare sensitivities and reading times. Results: 108 true positive nodules were found. Mean sensitivity was .68 for reading without CAD, .68 for concurrent reading and .75 for second reading. Differences of sensitivities were significant between concurrent and second reading (p<.001) resp. reading without CAD and second reading (p=.001). Mean reading time for concurrent reading was significant shorter (274s) compared to reading without CAD (294s;p=.04) and second reading (337sp<.001). New work to be presented: To our knowledge this is the first study that compares sensitivities and reading times between use of CAD as concurrent resp. second reader. Conclusion: CAD can either be used to speed up reading of chest CT cases for pulmonary nodules without loss of sensitivity as concurrent reader -OR (and not AND) to increase sensitivity and reading time as second reader.

  14. New results in computer-aided diagnosis (CAD) of breast cancer using a recently developed SVM/GRNN Oracle hybrid

    NASA Astrophysics Data System (ADS)

    Land, Walker H., Jr.; Wong, Lut; McKee, Daniel W.; Masters, Timothy; Anderson, Frances R.; Raturi, Anurag; Lo, Joseph Y.

    2004-05-01

    Breast cancer is second only to lung cancer as a tumor-related cause of death in women. Currently, the method of choice for the early detection of breast cancer is mammography. While sensitive to the detection of non palpable breast lesions, its positive predictive value (PPV) is low, resulting in biopsies that are only 15%-34% likely to reveal malignancy. This paper explores the use of a recently designed Support Vector Machine (SVM)/Generalized Regression Neural Network (GRNN) Oracle hybrid to classify breast lesions and evaluate the software's performance as an interpretive aid to radiologists. The main objective of the research was to perform an independent analysis, using a new, integrated film screen mammogram data base of approximately 2500 cases from five separate institutions, to verify results obtained previously[14]. This study demonstrated the following: (1) The DE crossover constant has little, if any, effect on measures of performance (MOP). (2) A specificity of approximately 5.6% is achieved at 100% sensitivity, which increases to approximately 36% at 95% sensitivity. (3) PPV increases from 51% to 56% as sensitivity is decreased from 100 to 95%, respectively.

  15. AutoCAD-To-NASTRAN Translator Program

    NASA Technical Reports Server (NTRS)

    Jones, A.

    1989-01-01

    Program facilitates creation of finite-element mathematical models from geometric entities. AutoCAD to NASTRAN translator (ACTON) computer program developed to facilitate quick generation of small finite-element mathematical models for use with NASTRAN finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Written in Microsoft Quick-Basic (Version 2.0).

  16. Mechanical Design Technology--Modified. (Computer Assisted Drafting, Computer Aided Design). Curriculum Grant 84/85.

    ERIC Educational Resources Information Center

    Schoolcraft Coll., Livonia, MI.

    This document is a curriculum guide for a program in mechanical design technology (computer-assisted drafting and design developed at Schoolcraft College, Livonia, Michigan). The program helps students to acquire the skills of drafters and to interact with electronic equipment, with the option of becoming efficient in the computer-aided…

  17. Improving the radiologist-CAD interaction: designing for appropriate trust.

    PubMed

    Jorritsma, W; Cnossen, F; van Ooijen, P M A

    2015-02-01

    Computer-aided diagnosis (CAD) has great potential to improve radiologists' diagnostic performance. However, the reported performance of the radiologist-CAD team is lower than what might be expected based on the performance of the radiologist and the CAD system in isolation. This indicates that the interaction between radiologists and the CAD system is not optimal. An important factor in the interaction between humans and automated aids (such as CAD) is trust. Suboptimal performance of the human-automation team is often caused by an inappropriate level of trust in the automation. In this review, we examine the role of trust in the radiologist-CAD interaction and suggest ways to improve the output of the CAD system so that it allows radiologists to calibrate their trust in the CAD system more effectively. Observer studies of the CAD systems show that radiologists often have an inappropriate level of trust in the CAD system. They sometimes under-trust CAD, thereby reducing its potential benefits, and sometimes over-trust it, leading to diagnostic errors they would not have made without CAD. Based on the literature on trust in human-automation interaction and the results of CAD observer studies, we have identified four ways to improve the output of CAD so that it allows radiologists to form a more appropriate level of trust in CAD. Designing CAD systems for appropriate trust is important and can improve the performance of the radiologist-CAD team. Future CAD research and development should acknowledge the importance of the radiologist-CAD interaction, and specifically the role of trust therein, in order to create the perfect artificial partner for the radiologist. This review focuses on the role of trust in the radiologist-CAD interaction. The aim of the review is to encourage CAD developers to design for appropriate trust and thereby improve the performance of the radiologist-CAD team. PMID:25459198

  18. Computer Aided Drafting and Design, Industrial Manufacturing Technician, and Mechanical Engineering Technician and Machine Tool, Die and Moldmaking Technology. Tech Prep Competency Profile.

    ERIC Educational Resources Information Center

    Mid-East Ohio Tech Prep Consortium, Zanesville.

    This document contains competency profiles in four areas: computer-aided drafting and design; industrial manufacturing technician; mechanical engineering technician; and machine tool, die, and moldmaking technology occupations. The profiles are intended for use in articulating tech prep programs from high school through associate degrees in Ohio.…

  19. Computer-Aided Drafting and Design Series. Educational Resources for the Machine Tool Industry, Course Syllabi, [and] Instructor's Handbook. Student Laboratory Manual.

    ERIC Educational Resources Information Center

    Texas State Technical Coll. System, Waco.

    This package consists of course syllabi, an instructor's handbook, and a student laboratory manual for a 2-year vocational training program to prepare students for entry-level employment in computer-aided drafting and design in the machine tool industry. The program was developed through a modification of the DACUM (Developing a Curriculum)…

  20. Viewing CAD Drawings on the Internet

    ERIC Educational Resources Information Center

    Schwendau, Mark

    2004-01-01

    Computer aided design (CAD) has been producing 3-D models for years. AutoCAD software is frequently used to create sophisticated 3-D models. These CAD files can be exported as 3DS files for import into Autodesk's 3-D Studio Viz. In this program, the user can render and modify the 3-D model before exporting it out as a WRL (world file hyperlinked)…

  1. Computing Mass Properties From AutoCAD

    NASA Technical Reports Server (NTRS)

    Jones, A.

    1990-01-01

    Mass properties of structures computed from data in drawings. AutoCAD to Mass Properties (ACTOMP) computer program developed to facilitate quick calculations of mass properties of structures containing many simple elements in such complex configurations as trusses or sheet-metal containers. Mathematically modeled in AutoCAD or compatible computer-aided design (CAD) system in minutes by use of three-dimensional elements. Written in Microsoft Quick-Basic (Version 2.0).

  2. Immersive CAD

    SciTech Connect

    Ames, A.L.

    1999-02-01

    This paper documents development of a capability for performing shape-changing editing operations on solid model representations in an immersive environment. The capability includes part- and assembly-level operations, with part modeling supporting topology-invariant and topology-changing modifications. A discussion of various design considerations in developing an immersive capability is included, along with discussion of a prototype implementation we have developed and explored. The project investigated approaches to providing both topology-invariant and topology-changing editing. A prototype environment was developed to test the approaches and determine the usefulness of immersive editing. The prototype showed exciting potential in redefining the CAD interface. It is fun to use. Editing is much faster and friendlier than traditional feature-based CAD software. The prototype algorithms did not reliably provide a sufficient frame rate for complex geometries, but has provided the necessary roadmap for development of a production capability.

  3. A CAD system based on spherical dual representations

    SciTech Connect

    Roach, J.W.; Paripati, P.K.; Wright, J.S.

    1987-08-01

    Computer-aided design (CAD) systems typically have many different functions: drafting, two-dimensional modeling, three-dimensional modeling, finite element analysis, and fit and tolerancing of parts. The authors report on the construction of a CAD system based on shape representation ideas used in the vision community to determine the shape of an object from its image. In the long term, they propose to construct a combined CAD and sensing system based on the same underlying object models. Considerable advantages follow from building a model-driven sensor fusion system that uses a common geometric model. In a manufacturing environment, for example, a library of objects can be built up and its models used in a vision and touch sensing system integrated into an automated assembly line to discriminate between objects and determine orientation and distance. If such a system could be made robust and highly reliable, then some of the most difficult problems that plague attempts to create a fully flexible automated environment would be solved.

  4. CAD Services: an Industry Standard Interface for Mechanical CAD Interoperability

    NASA Technical Reports Server (NTRS)

    Claus, Russell; Weitzer, Ilan

    2002-01-01

    Most organizations seek to design and develop new products in increasingly shorter time periods. At the same time, increased performance demands require a team-based multidisciplinary design process that may span several organizations. One approach to meet these demands is to use 'Geometry Centric' design. In this approach, design engineers team their efforts through one united representation of the design that is usually captured in a CAD system. Standards-based interfaces are critical to provide uniform, simple, distributed services that enable the 'Geometry Centric' design approach. This paper describes an industry-wide effort, under the Object Management Group's (OMG) Manufacturing Domain Task Force, to define interfaces that enable the interoperability of CAD, Computer Aided Manufacturing (CAM), and Computer Aided Engineering (CAE) tools. This critical link to enable 'Geometry Centric' design is called: Cad Services V1.0. This paper discusses the features of this standard and proposed application.

  5. Every Body Needs First Aid... A Manual for LEP Students [Draft] and Teacher Guide.

    ERIC Educational Resources Information Center

    Adachi, Patricia

    The manual contains both student and teacher materials for instruction in basic physiology and first aid. The instructional materials were developed for use with limited-English-proficient high school students, but are suitable for high school first aid classes because of their simplified English and format, sequential organization, detailed table…

  6. Assessment of the Incremental Benefit of Computer-Aided Detection (CAD) for Interpretation of CT Colonography by Experienced and Inexperienced Readers

    PubMed Central

    Boone, Darren; Mallett, Susan; McQuillan, Justine; Taylor, Stuart A.; Altman, Douglas G.; Halligan, Steve

    2015-01-01

    Objectives To quantify the incremental benefit of computer-assisted-detection (CAD) for polyps, for inexperienced readers versus experienced readers of CT colonography. Methods 10 inexperienced and 16 experienced radiologists interpreted 102 colonography studies unassisted and with CAD utilised in a concurrent paradigm. They indicated any polyps detected on a study sheet. Readers’ interpretations were compared against a ground-truth reference standard: 46 studies were normal and 56 had at least one polyp (132 polyps in total). The primary study outcome was the difference in CAD net benefit (a combination of change in sensitivity and change in specificity with CAD, weighted towards sensitivity) for detection of patients with polyps. Results Inexperienced readers’ per-patient sensitivity rose from 39.1% to 53.2% with CAD and specificity fell from 94.1% to 88.0%, both statistically significant. Experienced readers’ sensitivity rose from 57.5% to 62.1% and specificity fell from 91.0% to 88.3%, both non-significant. Net benefit with CAD assistance was significant for inexperienced readers but not for experienced readers: 11.2% (95%CI 3.1% to 18.9%) versus 3.2% (95%CI -1.9% to 8.3%) respectively. Conclusions Concurrent CAD resulted in a significant net benefit when used by inexperienced readers to identify patients with polyps by CT colonography. The net benefit was nearly four times the magnitude of that observed for experienced readers. Experienced readers did not benefit significantly from concurrent CAD. PMID:26355745

  7. CAD/CAM: Practical and Persuasive in Canadian Schools

    ERIC Educational Resources Information Center

    Willms, Ed

    2007-01-01

    Chances are that many high school students would not know how to use drafting instruments, but some might want to gain competence in computer-assisted design (CAD) and possibly computer-assisted manufacturing (CAM). These students are often attracted to tech courses by the availability of CAD/CAM instructions, and many go on to impress employers…

  8. Integrated computer-aided design using minicomputers

    NASA Technical Reports Server (NTRS)

    Storaasli, O. O.

    1980-01-01

    Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM), a highly interactive software, has been implemented on minicomputers at the NASA Langley Research Center. CAD/CAM software integrates many formerly fragmented programs and procedures into one cohesive system; it also includes finite element modeling and analysis, and has been interfaced via a computer network to a relational data base management system and offline plotting devices on mainframe computers. The CAD/CAM software system requires interactive graphics terminals operating at a minimum of 4800 bits/sec transfer rate to a computer. The system is portable and introduces 'interactive graphics', which permits the creation and modification of models interactively. The CAD/CAM system has already produced designs for a large area space platform, a national transonic facility fan blade, and a laminar flow control wind tunnel model. Besides the design/drafting element analysis capability, CAD/CAM provides options to produce an automatic program tooling code to drive a numerically controlled (N/C) machine. Reductions in time for design, engineering, drawing, finite element modeling, and N/C machining will benefit productivity through reduced costs, fewer errors, and a wider range of configuration.

  9. COMPUTER-AIDED DRAFTING AND DESIGN, A THREE-WEEK SUMMER INSTITUTE TRAINING PROGRAM (MIAMI-DADE JUNIOR COLLEGE, MIAMI, FLORIDA, JULY 10, 1967 - JULY 28, 1967). FINAL REPORT.

    ERIC Educational Resources Information Center

    MORPHONIOS, ALEX G.

    THIRTY-SIX INSTRUCTORS, SUPERVISORS, AND DEPARTMENT CHAIRMEN IN AREAS OF DRAFTING, ENGINEERING, MANUFACTURING, AND COMPUTER TECHNOLOGY AT JUNIOR COLLEGES, TECHNICAL, AND AREA VOCATIONAL SCHOOLS IN 20 STATES ATTENDED A 3-WEEK SUMMER INSTITUTE TRAINING PROGRAM ON COMPUTER-AIDED DRAFTING AND DESIGN. EXPERIENCE IN PROGRAMING THE IBM SYSTEM 1620 WITH…

  10. Multi-site evaluation of a computer aided detection (CAD) algorithm for small acute intra-cranial hemorrhage and development of a stand-alone CAD system ready for deployment in a clinical environment

    NASA Astrophysics Data System (ADS)

    Deshpande, Ruchi R.; Fernandez, James; Lee, Joon K.; Chan, Tao; Liu, Brent J.; Huang, H. K.

    2010-03-01

    Timely detection of Acute Intra-cranial Hemorrhage (AIH) in an emergency environment is essential for the triage of patients suffering from Traumatic Brain Injury. Moreover, the small size of lesions and lack of experience on the reader's part could lead to difficulties in the detection of AIH. A CT based CAD algorithm for the detection of AIH has been developed in order to improve upon the current standard of identification and treatment of AIH. A retrospective analysis of the algorithm has already been carried out with 135 AIH CT studies with 135 matched normal head CT studies from the Los Angeles County General Hospital/ University of Southern California Hospital System (LAC/USC). In the next step, AIH studies have been collected from Walter Reed Army Medical Center, and are currently being processed using the AIH CAD system as part of implementing a multi-site assessment and evaluation of the performance of the algorithm. The sensitivity and specificity numbers from the Walter Reed study will be compared with the numbers from the LAC/USC study to determine if there are differences in the presentation and detection due to the difference in the nature of trauma between the two sites. Simultaneously, a stand-alone system with a user friendly GUI has been developed to facilitate implementation in a clinical setting.

  11. Project CAD as of July 1978: CAD support project, situation in July 1978

    NASA Technical Reports Server (NTRS)

    Boesch, L.; Lang-Lendorff, G.; Rothenberg, R.; Stelzer, V.

    1979-01-01

    The structure of Computer Aided Design (CAD) and the requirements for program developments in past and future are described. The actual standard and the future aims of CAD programs are presented. The developed programs in: (1) civil engineering; (2) mechanical engineering; (3) chemical engineering/shipbuilding; (4) electrical engineering; and (5) general programs are discussed.

  12. Effectiveness of using CADD (Computer-Aided Design Drafting) to learn engineering design graphics

    SciTech Connect

    Bertoline, G.R.

    1987-01-01

    One commercial CADD software and one educational CADD software was compared to the use of traditional tools. Engineering-graphics students were divided into three groups. The control group used traditional tools for all their drawings. One experimental group used a commercial CADD software to supplement hand tools and one group used an educational CADD software to supplement traditional tools. These groups were then post-tested using a standardized drafting test. The main findings were: (1) There was no significant difference in the learning of engineering graphics as measured by the post-tests. Supplementing traditional tools with CADD is effective for teaching engineering design graphics. (2) Using CADD for detail drawings such as simple orthographic drawings, sections, and dimensions could be produced in approximately the same amount of time as using traditional tools. (3) It was found that the amount of time needed to solve descriptive geometry problems using CADD was prohibitive. The amount of time to solve some descriptive geometry problems was two or three times greater using CADD versus traditional tools.

  13. Cad Graphics in Facilities Planning.

    ERIC Educational Resources Information Center

    Collier, Linda M.

    1984-01-01

    By applying a computer-aided drafting system to a range of facilities layouts and plans, a division of Tektronix, Inc., Oregon, is maintaining staffing levels with an added workload. The tool is also being used in other areas of the company for illustration, design, and administration. (MLF)

  14. Some Workplace Effects of CAD and CAM.

    ERIC Educational Resources Information Center

    Ebel, Karl-H.; Ulrich, Erhard

    1987-01-01

    Examines the impact of computer-aided design (CAD) and computer-aided manufacturing (CAM) on employment, work organization, working conditions, job content, training, and industrial relations in several countries. Finds little evidence of negative employment effects since productivity gains are offset by various compensatory factors. (Author/CH)

  15. Basic Drafting: Book Two.

    ERIC Educational Resources Information Center

    Davis, Ronald; And Others

    The second of a two-book course in drafting, this manual consists of 12 topics in the following units: sketching techniques, geometric constructions, orthographic views, dimensioning procedures, basic tolerancing, auxiliary views, sectional views, inking tools and techniques, axonometrics, oblique, perspective, and computer-aided drafting.…

  16. Turnkey CAD/CAM systems' integration with IPAD systems

    NASA Technical Reports Server (NTRS)

    Blauth, R. E.

    1980-01-01

    Today's commercially available turnkey CAD/CAM systems provide a highly interactive environment, and support many specialized application functions for the design/drafting/manufacturing process. This paper presents an overview of several aerospace companies which have successfully integrated turnkey CAD/CAM systems with their own company wide engineering and manufacturing systems. It also includes a vendor's view of the benefits as well as the disadvantages of such integration efforts. Specific emphasis is placed upon the selection of standards for representing geometric engineering data and for communicating such information between different CAD/CAM systems.

  17. Informatics infrastructure of CAD system.

    PubMed

    Pietka, Ewa; Gertych, Arkadiusz; Witko, Krzysztof

    2005-01-01

    A computer aided diagnosis (CAD) system requires several components which influence its effectiveness. An image processing methodology is responsible for the analysis, database structure archives and distributes the patient demographics, clinical information, and image data. A graphical user interface is applied in order to enter the data and present it to the user. By designing dynamic Web pages a remote access to the entire is granted. The computer aided diagnosis system includes three layers, which might be installed on various platforms. Elements of the application software are designed independently. Integration of all components is another issue discussed in the presented paper. Implementation of a computer aided diagnosis system improves and accelerates the analysis by giving to the user objective measurement tools. It also standardizes the decision-making process and solves the problem of replicability. Finally, it permits a set of images and features to be collected and recognized as a medical standard and be applied in education and research. PMID:15755535

  18. An Evaluation of Internet-Based CAD Collaboration Tools

    ERIC Educational Resources Information Center

    Smith, Shana Shiang-Fong

    2004-01-01

    Due to the now widespread use of the Internet, most companies now require computer aided design (CAD) tools that support distributed collaborative design on the Internet. Such CAD tools should enable designers to share product models, as well as related data, from geographically distant locations. However, integrated collaborative design…

  19. An Instructional Method for the AutoCAD Modeling Environment.

    ERIC Educational Resources Information Center

    Mohler, James L.

    1997-01-01

    Presents a command organizer for AutoCAD to aid new uses in operating within the 3-D modeling environment. Addresses analyzing the problem, visualization skills, nonlinear tools, a static view of a dynamic model, the AutoCAD organizer, environment attributes, and control of the environment. Contains 11 references. (JRH)

  20. An application protocol for CAD to CAD transfer of electronic information

    NASA Technical Reports Server (NTRS)

    Azu, Charles C., Jr.

    1993-01-01

    The exchange of Computer Aided Design (CAD) information between dissimilar CAD systems is a problem. This is especially true for transferring electronics CAD information such as multi-chip module (MCM), hybrid microcircuit assembly (HMA), and printed circuit board (PCB) designs. Currently, there exists several neutral data formats for transferring electronics CAD information. These include IGES, EDIF, and DXF formats. All these formats have limitations for use in exchanging electronic data. In an attempt to overcome these limitations, the Navy's MicroCIM program implemented a project to transfer hybrid microcircuit design information between dissimilar CAD systems. The IGES (Initial Graphics Exchange Specification) format is used since it is well established within the CAD industry. The goal of the project is to have a complete transfer of microelectronic CAD information, using IGES, without any data loss. An Application Protocol (AP) is being developed to specify how hybrid microcircuit CAD information will be represented by IGES entity constructs. The AP defines which IGES data items are appropriate for describing HMA geometry, connectivity, and processing as well as HMA material characteristics.

  1. A Case Study in CAD Design Automation

    ERIC Educational Resources Information Center

    Lowe, Andrew G.; Hartman, Nathan W.

    2011-01-01

    Computer-aided design (CAD) software and other product life-cycle management (PLM) tools have become ubiquitous in industry during the past 20 years. Over this time they have continuously evolved, becoming programs with enormous capabilities, but the companies that use them have not evolved their design practices at the same rate. Due to the…

  2. CAD-CAE in Electrical Machines and Drives Teaching.

    ERIC Educational Resources Information Center

    Belmans, R.; Geysen, W.

    1988-01-01

    Describes the use of computer-aided design (CAD) techniques in teaching the design of electrical motors. Approaches described include three technical viewpoints, such as electromagnetics, thermal, and mechanical aspects. Provides three diagrams, a table, and conclusions. (YP)

  3. Overview of NASA MSFC IEC Multi-CAD Collaboration Capability

    NASA Technical Reports Server (NTRS)

    Moushon, Brian; McDuffee, Patrick

    2005-01-01

    This viewgraph presentation provides an overview of a Design and Data Management System (DDMS) for Computer Aided Design (CAD) collaboration in order to support the Integrated Engineering Capability (IEC) at Marshall Space Flight Center (MSFC).

  4. A CAD System for Hemorrhagic Stroke.

    PubMed

    Nowinski, Wieslaw L; Qian, Guoyu; Hanley, Daniel F

    2014-09-01

    Computer-aided detection/diagnosis (CAD) is a key component of routine clinical practice, increasingly used for detection, interpretation, quantification and decision support. Despite a critical need, there is no clinically accepted CAD system for stroke yet. Here we introduce a CAD system for hemorrhagic stroke. This CAD system segments, quantifies, and displays hematoma in 2D/3D, and supports evacuation of hemorrhage by thrombolytic treatment monitoring progression and quantifying clot removal. It supports seven-step workflow: select patient, add a new study, process patient's scans, show segmentation results, plot hematoma volumes, show 3D synchronized time series hematomas, and generate report. The system architecture contains four components: library, tools, application with user interface, and hematoma segmentation algorithm. The tools include a contour editor, 3D surface modeler, 3D volume measure, histogramming, hematoma volume plot, and 3D synchronized time-series hematoma display. The CAD system has been designed and implemented in C++. It has also been employed in the CLEAR and MISTIE phase-III, multicenter clinical trials. This stroke CAD system is potentially useful in research and clinical applications, particularly for clinical trials.

  5. Prevention of Substance Abuse and AIDS Risk Behaviors in Adolescents: Is any Real Progress Being Made? Draft.

    ERIC Educational Resources Information Center

    Evans, Richard I.

    Although a great deal of effort has been devoted to the prevention of substance abuse and AIDS risk behaviors in adolescents, the success of such programs can be difficult to measure. This study, in Northeast Houston-Harris County, Texas, examines adolescent attitudes and behaviors toward sexual activity and AIDS and discusses barriers facing…

  6. Cost reduction advantages of CAD/CAM

    NASA Astrophysics Data System (ADS)

    Parsons, G. T.

    1983-05-01

    Features of the CAD/CAM system implemented at the General Dynamics Convair division are summarized. CAD/CAM was initiated in 1976 to enhance engineering, manufacturing and quality assurance and thereby the company's competitive bidding position. Numerical models are substituted for hardware models wherever possible and numerical criteria are defined in design for guiding computer-controlled parts manufacturing machines. The system comprises multiple terminals, a data base, digitizer, printers, disk and tape drives, and graphics displays. The applications include the design and manufacture of parts and components for avionics, structures, scientific investigations, and aircraft structural components. Interfaces with other computers allow structural analyses by finite element codes. Although time savings have not been gained compared to manual drafting, components of greater complexity than could have been designed by hand have been designed and manufactured.

  7. AutoCAD-To-GIFTS Translator Program

    NASA Technical Reports Server (NTRS)

    Jones, Andrew

    1989-01-01

    AutoCAD-to-GIFTS translator program, ACTOG, developed to facilitate quick generation of small finite-element models using CASA/GIFTS finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Geometric entities recognized by ACTOG include points, lines, arcs, solids, three-dimensional lines, and three-dimensional faces. From this information, ACTOG creates GIFTS SRC file, which then reads into GIFTS preprocessor BULKM or modified and reads into EDITM to create finite-element model. SRC file used as is or edited for any number of uses. Written in Microsoft Quick-Basic (Version 2.0).

  8. Computer aided production engineering

    SciTech Connect

    Not Available

    1986-01-01

    This book presents the following contents: CIM in avionics; computer analysis of product designs for robot assembly; a simulation decision mould for manpower forecast and its application; development of flexible manufacturing system; advances in microcomputer applications in CAD/CAM; an automated interface between CAD and process planning; CAM and computer vision; low friction pneumatic actuators for accurate robot control; robot assembly of printed circuit boards; information systems design for computer integrated manufacture; and a CAD engineering language to aid manufacture.

  9. Computer-aided design development transition for IPAD environment

    NASA Technical Reports Server (NTRS)

    Owens, H. G.; Mock, W. D.; Mitchell, J. C.

    1980-01-01

    The relationship of federally sponsored computer-aided design/computer-aided manufacturing (CAD/CAM) programs to the aircraft life cycle design process, an overview of NAAD'S CAD development program, an evaluation of the CAD design process, a discussion of the current computing environment within which NAAD is developing its CAD system, some of the advantages/disadvantages of the NAAD-IPAD approach, and CAD developments during transition into the IPAD system are discussed.

  10. Schools (Students) Exchanging CAD/CAM Files over the Internet.

    ERIC Educational Resources Information Center

    Mahoney, Gary S.; Smallwood, James E.

    This document discusses how students and schools can benefit from exchanging computer-aided design/computer-aided manufacturing (CAD/CAM) files over the Internet, explains how files are exchanged, and examines the problem of selected hardware/software incompatibility. Key terms associated with information search services are defined, and several…

  11. Westinghouse Idaho Nuclear Company, Inc. (WINCO) CAD activities at the Idaho Chemical Processing Plant (ICPP) (Idaho Engineering Laboratory)

    SciTech Connect

    Jensen, B.

    1989-04-18

    June 1985 -- The drafting manager obtained approval to implement a cad system at the ICPP. He formed a committee to evaluate the various cad systems and recommend a system that would most benefit the ICPP. A PC'' (personal computer) based system using Autocad software was recommended in lieu of the much more expensive main frame based systems.

  12. Westinghouse Idaho Nuclear Company, Inc. (WINCO) CAD activities at the Idaho Chemical Processing Plant (ICPP) (Idaho Engineering Laboratory)

    SciTech Connect

    Jensen, B.

    1989-04-18

    June 1985 -- The drafting manager obtained approval to implement a cad system at the ICPP. He formed a committee to evaluate the various cad systems and recommend a system that would most benefit the ICPP. A ``PC`` (personal computer) based system using Autocad software was recommended in lieu of the much more expensive main frame based systems.

  13. Resin-composite Blocks for Dental CAD/CAM Applications

    PubMed Central

    Ruse, N.D.; Sadoun, M.J.

    2014-01-01

    Advances in digital impression technology and manufacturing processes have led to a dramatic paradigm shift in dentistry and to the widespread use of computer-aided design/computer-aided manufacturing (CAD/CAM) in the fabrication of indirect dental restorations. Research and development in materials suitable for CAD/CAM applications are currently the most active field in dental materials. Two classes of materials are used in the production of CAD/CAM restorations: glass-ceramics/ceramics and resin composites. While glass-ceramics/ceramics have overall superior mechanical and esthetic properties, resin-composite materials may offer significant advantages related to their machinability and intra-oral reparability. This review summarizes recent developments in resin-composite materials for CAD/CAM applications, focusing on both commercial and experimental materials. PMID:25344335

  14. Resin-composite blocks for dental CAD/CAM applications.

    PubMed

    Ruse, N D; Sadoun, M J

    2014-12-01

    Advances in digital impression technology and manufacturing processes have led to a dramatic paradigm shift in dentistry and to the widespread use of computer-aided design/computer-aided manufacturing (CAD/CAM) in the fabrication of indirect dental restorations. Research and development in materials suitable for CAD/CAM applications are currently the most active field in dental materials. Two classes of materials are used in the production of CAD/CAM restorations: glass-ceramics/ceramics and resin composites. While glass-ceramics/ceramics have overall superior mechanical and esthetic properties, resin-composite materials may offer significant advantages related to their machinability and intra-oral reparability. This review summarizes recent developments in resin-composite materials for CAD/CAM applications, focusing on both commercial and experimental materials.

  15. HIV / AIDS and employment code of good practice. Draft for the National Economic Development and Labour Council -August 1995.

    PubMed

    1995-11-01

    International labor standards dictate that human immunodeficiency virus (HIV) infection and acquired immunodeficiency syndrome (AIDS) be treated as any other life-threatening medical condition, with no undue burden placed on employees. Toward this end, South African human rights advocates have prepared an HIV/AIDS Employment Code of Good Practice for presentation to the National Economic Development and Labor Council. Moreover, it is being recommended that the Code be appended to the 1995 Labor Relations Act. The Code is expected to provide a basis for fair employment policy and a reference point for resolving disputes in the proposed Conciliation, Mediation, and Arbitration Commission. The Code prohibits pre-employment HIV screening and stipulates that HIV status cannot be used as a basis for denying training or promotion opportunities. Employees known to be HIV-positive shall be ensured confidentiality and provided with full access to employment benefits. When illness progresses to the point where an employee can no longer perform his or her duties, another more appropriate position should be located; if this is not possible, or if the employee is too ill to work, termination due to incapacity may be considered, but with the continuation of full company benefits. Mechanisms of redress should be identified for HIV-infected employees with discrimination-related grievances. The Code further mandates the provision of compulsory AIDS education programs to combat misinformation at the workplace. Disciplinary measures against an employee who refuses to work with an infected co-worker are sanctioned.

  16. Using a commercial CAD system for simultaneous input to theoretical aerodynamic programs and wind-tunnel model construction

    NASA Technical Reports Server (NTRS)

    Enomoto, F.; Keller, P.

    1984-01-01

    The Computer Aided Design (CAD) system's common geometry database was used to generate input for theoretical programs and numerically controlled (NC) tool paths for wind tunnel part fabrication. This eliminates the duplication of work in generating separate geometry databases for each type of analysis. Another advantage is that it reduces the uncertainty due to geometric differences when comparing theoretical aerodynamic data with wind tunnel data. The system was adapted to aerodynamic research by developing programs written in Design Analysis Language (DAL). These programs reduced the amount of time required to construct complex geometries and to generate input for theoretical programs. Certain shortcomings of the Design, Drafting, and Manufacturing (DDM) software limited the effectiveness of these programs and some of the Calma NC software. The complexity of aircraft configurations suggests that more types of surface and curve geometry should be added to the system. Some of these shortcomings may be eliminated as improved versions of DDM are made available.

  17. Computer-Aided Design in Further Education.

    ERIC Educational Resources Information Center

    Ingham, Peter, Ed.

    This publication updates the 1982 occasional paper that was intended to foster staff awareness and assist colleges in Great Britain considering the use of computer-aided design (CAD) material in engineering courses. The paper begins by defining CAD and its place in the Integrated Business System with a brief discussion of the effect of CAD on the…

  18. Group technology methods for integrated CAD/CAM

    NASA Astrophysics Data System (ADS)

    Propen, M.; Jacko, J.

    1984-10-01

    The use of a single product definition and comprehensive database are key factors in integrating CAD and CAM. This paper describes one approach for investigating the scope of developing a full scale Group Technology (GT) system. The prototype GT system discussed required the integration of a decision logic processor, relational database, and design/drafting system, and demonstrated a generative process planning system for a family of gas turbine engine components.

  19. Generating Composite Overlapping Grids on CAD Geometries

    SciTech Connect

    Henshaw, W.D.

    2002-02-07

    We describe some algorithms and tools that have been developed to generate composite overlapping grids on geometries that have been defined with computer aided design (CAD) programs. This process consists of five main steps. Starting from a description of the surfaces defining the computational domain we (1) correct errors in the CAD representation, (2) determine topology of the patched-surface, (3) build a global triangulation of the surface, (4) construct structured surface and volume grids using hyperbolic grid generation, and (5) generate the overlapping grid by determining the holes and the interpolation points. The overlapping grid generator which is used for the final step also supports the rapid generation of grids for block-structured adaptive mesh refinement and for moving grids. These algorithms have been implemented as part of the Overture object-oriented framework.

  20. CAD/CAM systems, materials, and clinical guidelines for all-ceramic crowns and fixed partial dentures.

    PubMed

    McLaren, Edward A; Terry, Douglas A

    2002-07-01

    Advances in dental ceramic materials and the development of computer-aided design/computer-aided manufacturing (CAD/CAM) and milling technology have facilitated the development and application of superior dental ceramics. CAD/CAM allows the use of materials that cannot be used with conventional dental processing techniques. This article reviews the main techniques and new materials used in dentistry for CAD/CAM-generated crowns and fixed partial dentures. Also covered are the clinical guidelines for using these systems.

  1. The Use of a Parametric Feature Based CAD System to Teach Introductory Engineering Graphics.

    ERIC Educational Resources Information Center

    Howell, Steven K.

    1995-01-01

    Describes the use of a parametric-feature-based computer-aided design (CAD) System, AutoCAD Designer, in teaching concepts of three dimensional geometrical modeling and design. Allows engineering graphics to go beyond the role of documentation and communication and allows an engineer to actually build a virtual prototype of a design idea and…

  2. Teaching an Introductory CAD Course with the System-Engineering Approach.

    ERIC Educational Resources Information Center

    Pao, Y. C.

    1985-01-01

    Advocates that introductory computer aided design (CAD) courses be incorporated into engineering curricula in close conjunction with the system dynamics course. Block diagram manipulation/Bode analysis and finite elementary analysis are used as examples to illustrate the interdisciplinary nature of CAD teaching. (JN)

  3. A new CAD approach for improving efficacy of cancer screening

    NASA Astrophysics Data System (ADS)

    Zheng, Bin; Qian, Wei; Li, Lihua; Pu, Jiantao; Kang, Yan; Lure, Fleming; Tan, Maxine; Qiu, Yuchen

    2015-03-01

    Since performance and clinical utility of current computer-aided detection (CAD) schemes of detecting and classifying soft tissue lesions (e.g., breast masses and lung nodules) is not satisfactory, many researchers in CAD field call for new CAD research ideas and approaches. The purpose of presenting this opinion paper is to share our vision and stimulate more discussions of how to overcome or compensate the limitation of current lesion-detection based CAD schemes in the CAD research community. Since based on our observation that analyzing global image information plays an important role in radiologists' decision making, we hypothesized that using the targeted quantitative image features computed from global images could also provide highly discriminatory power, which are supplementary to the lesion-based information. To test our hypothesis, we recently performed a number of independent studies. Based on our published preliminary study results, we demonstrated that global mammographic image features and background parenchymal enhancement of breast MR images carried useful information to (1) predict near-term breast cancer risk based on negative screening mammograms, (2) distinguish between true- and false-positive recalls in mammography screening examinations, and (3) classify between malignant and benign breast MR examinations. The global case-based CAD scheme only warns a risk level of the cases without cueing a large number of false-positive lesions. It can also be applied to guide lesion-based CAD cueing to reduce false-positives but enhance clinically relevant true-positive cueing. However, before such a new CAD approach is clinically acceptable, more work is needed to optimize not only the scheme performance but also how to integrate with lesion-based CAD schemes in the clinical practice.

  4. CAD/CAM for optomechatronics

    NASA Astrophysics Data System (ADS)

    Zhou, Haiguang; Han, Min

    2003-10-01

    We focus at CAD/CAM for optomechatronics. We have developed a kind of CAD/CAM, which is not only for mechanics but also for optics and electronic. The software can be used for training and education. We introduce mechanical CAD, optical CAD and electrical CAD, we show how to draw a circuit diagram, mechanical diagram and luminous transmission diagram, from 2D drawing to 3D drawing. We introduce how to create 2D and 3D parts for optomechatronics, how to edit tool paths, how to select parameters for process, how to run the post processor, dynamic show the tool path and generate the CNC programming. We introduce the joint application of CAD&CAM. We aim at how to match the requirement of optical, mechanical and electronics.

  5. Computer Aided Design in Engineering Education.

    ERIC Educational Resources Information Center

    Gobin, R.

    1986-01-01

    Discusses the use of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) systems in an undergraduate engineering education program. Provides a rationale for CAD/CAM use in the already existing engineering program. Describes the methods used in choosing the systems, some initial results, and warnings for first-time users. (TW)

  6. Computerized design of CAD

    NASA Astrophysics Data System (ADS)

    Paul, B. E.; Pham, T. A.

    1982-11-01

    A computerized ballistic design technique for CAD/PAD is described by which a set of ballistic design parameters are determined, all of which satisfy a particular performance requirement. In addition, the program yields the remaining performance predictions, so that only a very few computer runs of the design program can quickly bring the ballistic design within the specification limits prescribed. An example is presented for a small propulsion device, such as a remover or actuator, for which the input specifications define a maximum allowable thrust and minimum end-of-stroke velocity. The resulting output automatically satisfies the input requirements, and will always yield an acceptable ballistic design.

  7. Correlating Trainee Attributes to Performance in 3D CAD Training

    ERIC Educational Resources Information Center

    Hamade, Ramsey F.; Artail, Hassan A.; Sikstrom, Sverker

    2007-01-01

    Purpose: The purpose of this exploratory study is to identify trainee attributes relevant for development of skills in 3D computer-aided design (CAD). Design/methodology/approach: Participants were trained to perform cognitive tasks of comparable complexity over time. Performance data were collected on the time needed to construct test models, and…

  8. Program Evolves from Basic CAD to Total Manufacturing Experience

    ERIC Educational Resources Information Center

    Cassola, Joel

    2011-01-01

    Close to a decade ago, John Hersey High School (JHHS) in Arlington Heights, Illinois, made a transition from a traditional classroom-based pre-engineering program. The new program is geared towards helping students understand the entire manufacturing process. Previously, a JHHS student would design a project in computer-aided design (CAD) software…

  9. Construction and study of a standard TWT MMACE drafting example

    SciTech Connect

    Thelen, D.; Hillenberg, S.

    1996-12-31

    MMACE (Microwave and Millimeter-wave Advanced Computational Environment) is being developed with a primary focus on simulation of linear-beam microwave devices. Device information is entered into MMACE via either (1) CAD drawings or (2) parameters entered by the user. CAD drawing files are annotated with material information (names and/or properties) and specifications of electron beam simulation regions. MMACE CAD simulation codes use information obtained form the CAD drawing files to predict performance characteristics of the particular design. Parameters entered by the user for use in MMACE parametric codes include physical dimensions and rf quantities, such as helix circuit loss per unit axial length. Some MMACE parametric codes, such as the code for the electron gun section, output design information instead of simulation results. The authors have generated a MMACE CAD drafting model of an example 40W helix TWT from its construction drawings. This CAD example will be used as standardized input for evaluating new MMACE simulation codes.

  10. An Algorithm for Projecting Points onto a Patched CAD Model

    SciTech Connect

    Henshaw, W D

    2001-05-29

    We are interested in building structured overlapping grids for geometries defined by computer-aided-design (CAD) packages. Geometric information defining the boundary surfaces of a computation domain is often provided in the form of a collection of possibly hundreds of trimmed patches. The first step in building an overlapping volume grid on such a geometry is to build overlapping surface grids. A surface grid is typically built using hyperbolic grid generation; starting from a curve on the surface, a grid is grown by marching over the surface. A given hyperbolic grid will typically cover many of the underlying CAD surface patches. The fundamental operation needed for building surface grids is that of projecting a point in space onto the closest point on the CAD surface. We describe an fast algorithm for performing this projection, it will make use of a fairly coarse global triangulation of the CAD geometry. We describe how to build this global triangulation by first determining the connectivity of the CAD surface patches. This step is necessary since it often the case that the CAD description will contain no information specifying how a given patch connects to other neighboring patches. Determining the connectivity is difficult since the surface patches may contain mistakes such as gaps or overlaps between neighboring patches.

  11. CAD/CAM data management

    NASA Technical Reports Server (NTRS)

    Bray, O. H.

    1984-01-01

    The role of data base management in CAD/CAM, particularly for geometric data is described. First, long term and short term objectives for CAD/CAM data management are identified. Second, the benefits of the data base management approach are explained. Third, some of the additional work needed in the data base area is discussed.

  12. False positive reduction for lung nodule CAD

    NASA Astrophysics Data System (ADS)

    Zhao, Luyin; Boroczky, Lilla; Drysdale, Jeremy; Agnihotri, Lalitha; Lee, Michael C.

    2007-03-01

    Computer-aided detection (CAD) algorithms 'automatically' identify lung nodules on thoracic multi-slice CT scans (MSCT) thereby providing physicians with a computer-generated 'second opinion'. While CAD systems can achieve high sensitivity, their limited specificity has hindered clinical acceptance. To overcome this problem, we propose a false positive reduction (FPR) system based on image processing and machine learning to reduce the number of false positive lung nodules identified by CAD algorithms and thereby improve system specificity. To discriminate between true and false nodules, twenty-three 3D features were calculated from each candidate nodule's volume of interest (VOI). A genetic algorithm (GA) and support vector machine (SVM) were then used to select an optimal subset of features from this pool of candidate features. Using this feature subset, we trained an SVM classifier to eliminate as many false positives as possible while retaining all the true nodules. To overcome the imbalanced nature of typical datasets (significantly more false positives than true positives), an intelligent data selection algorithm was designed and integrated into the machine learning framework, thus further improving the FPR rate. Three independent datasets were used to train and validate the system. Using two datasets for training and the third for validation, we achieved a 59.4% FPR rate while removing one true nodule on the validation datasets. In a second experiment, 75% of the cases were randomly selected from each of the three datasets and the remaining cases were used for validation. A similar FPR rate and true positive retention rate was achieved. Additional experiments showed that the GA feature selection process integrated with the proposed data selection algorithm outperforms the one without it by 5%-10% FPR rate. The methods proposed can be also applied to other application areas, such as computer-aided diagnosis of lung nodules.

  13. How to Quickly Import CAD Geometry into Thermal Desktop

    NASA Astrophysics Data System (ADS)

    Wright, Shonte; Beltran, Emilio

    2002-07-01

    There are several groups at JPL (Jet Propulsion Laboratory) that are committed to concurrent design efforts, two are featured here. Center for Space Mission Architecture and Design (CSMAD) enables the practical application of advanced process technologies in JPL's mission architecture process. Team I functions as an incubator for projects that are in the Discovery, and even pre-Discovery proposal stages. JPL's concurrent design environment is to a large extent centered on the CAD (Computer Aided Design) file. During concurrent design sessions CAD geometry is ported to other more specialized engineering design packages.

  14. Construction CAE; Integration of CAD, simulation, planning and cost control

    SciTech Connect

    Wickard, D.A. ); Bill, R.D.; Gates, K.H.; Yoshinaga, T.; Ohcoshi, S. )

    1989-01-01

    Construction CAE is a simulation, planning, scheduling, and cost control tool that is integrated with a computer aided design (CAD) system. The system uses a CAD model and allows the user to perform construction simulation on objects defined within the model. Initial cost/schedule reports as well as those required for project chronicling are supported through an interface to a work breakdown structure (WBS) and a client's existing schedule reporting system. By integrating currently available project control tools with a simulation system, Construction CAE is more effective than its individual components.

  15. Performance evaluation of the NASA/KSC CAD/CAE and office automation LAN's

    NASA Technical Reports Server (NTRS)

    Zobrist, George W.

    1994-01-01

    This study's objective is the performance evaluation of the existing CAD/CAE (Computer Aided Design/Computer Aided Engineering) network at NASA/KSC. This evaluation also includes a similar study of the Office Automation network, since it is being planned to integrate this network into the CAD/CAE network. The Microsoft mail facility which is presently on the CAD/CAE network was monitored to determine its present usage. This performance evaluation of the various networks will aid the NASA/KSC network managers in planning for the integration of future workload requirements into the CAD/CAE network and determining the effectiveness of the planned FDDI (Fiber Distributed Data Interface) migration.

  16. Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns

    PubMed Central

    Kwon, Taek-Ka; Pak, Hyun-Soon; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun

    2013-01-01

    PURPOSE All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. MATERIALS AND METHODS Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. RESULTS The mean fracture strengths were as follows: 54.9 ± 15.6 N for the Lava CAD/CAM zirconia crowns and 87.0 ± 16.0 N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. CONCLUSION The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain. PMID:23755332

  17. Architectural Drafting.

    ERIC Educational Resources Information Center

    Davis, Ronald; Yancey, Bruce

    Designed to be used as a supplement to a two-book course in basic drafting, these instructional materials consisting of 14 units cover the process of drawing all working drawings necessary for residential buildings. The following topics are covered in the individual units: introduction to architectural drafting, lettering and tools, site…

  18. Civil Drafting.

    ERIC Educational Resources Information Center

    Schertz, Karen; Kellum, Mary, Ed.

    This curriculum guide contains a course in civil drafting to train entry-level workers for jobs in the field. The module contains 12 instructional units that cover the following topics: (1) introduction to civil drafting; (2) map scales and measurement; (3) standard symbols and abbreviations; (4) interpretation of surveyor's notations; (5) legal…

  19. Mechanical Drafting.

    ERIC Educational Resources Information Center

    McClain, Gerald R.

    This publication, the third in a series on drafting, is intended to strengthen students' competence in the specialized field of mechanical drafting. The text consists of instructional materials for both teacher and students, written in terms of student performance using measurable objectives. The course includes 11 units. Each instructional unit…

  20. Comparing performance of the CADstream and the DynaCAD breast MRI CAD systems : CADstream vs. DynaCAD in breast MRI.

    PubMed

    Pan, Joann; Dogan, Basak E; Carkaci, Selin; Santiago, Lumarie; Arribas, Elsa; Cantor, Scott B; Wei, Wei; Stafford, R Jason; Whitman, Gary J

    2013-10-01

    Computer-aided diagnosis (CAD) systems are software programs that use algorithms to find patterns associated with breast cancer on breast magnetic resonance imaging (MRI). The most commonly used CAD systems in the USA are CADstream (CS) (Merge Healthcare Inc., Chicago, IL) and DynaCAD for Breast (DC) (Invivo, Gainesville, FL). Our primary objective in this study was to compare the CS and DC breast MRI CAD systems for diagnostic accuracy and postprocessed image quality. Our secondary objective was to compare the evaluation times of radiologists using each system. Three radiologists evaluated 30 biopsy-proven malignant lesions and 29 benign lesions on CS and DC and rated the lesions' malignancy status using the Breast Imaging Reporting and Data System. Image quality was ranked on a 0-5 scale, and mean reading times were also recorded. CS detected 70 % of the malignant and 32 % of the benign lesions while DC detected 81 % of the malignant lesions and 34 % of the benign lesions. Analysis of the area under the receiver operating characteristic curve revealed that the difference in diagnostic performance was not statistically significant. On image quality scores, CS had significantly higher volume rendering (VR) (p < 0.0001) and motion correction (MC) scores (p < 0.0001). There were no statistically significant differences in the remaining image quality scores. Differences in evaluation times between DC and CS were also not statistically significant. We conclude that both CS and DC perform similarly in aiding detection of breast cancer on MRI. MRI CAD selection will likely be based on other factors, such as user interface and image quality preferences, including MC and VR. PMID:23589186

  1. An Educational Exercise Examining the Role of Model Attributes on the Creation and Alteration of CAD Models

    ERIC Educational Resources Information Center

    Johnson, Michael D.; Diwakaran, Ram Prasad

    2011-01-01

    Computer-aided design (CAD) is a ubiquitous tool that today's students will be expected to use proficiently for numerous engineering purposes. Taking full advantage of the features available in modern CAD programs requires that models are created in a manner that allows others to easily understand how they are organized and alter them in an…

  2. CAD May Not be Necessary for Microcalcifications in the Digital era, CAD May Benefit Radiologists for Masses

    PubMed Central

    Destounis, Stamatia V.; Arieno, Andrea L.; Morgan, Renee C.

    2012-01-01

    Objective: The aim of this study was to evaluate the effectiveness of computer-aided detection (CAD) to mark the cancer on digital mammograms at the time of breast cancer diagnosis and also review retrospectively whether CAD marked the cancer if visible on any available prior mammograms, thus potentially identifying breast cancer at an earlier stage. We sought to determine why breast lesions may or may not be marked by CAD. In particular, we analyzed factors such as breast density, mammographic views, and lesion characteristics. Materials and Methods: Retrospective review from 2004 to 2008 revealed 3445 diagnosed breast cancers in both symptomatic and asymptomatic patients; 1293 of these were imaged with full field digital mammography (FFDM). After cancer diagnosis, in a retrospective review held by the radiologist staff, 43 of these cancers were found to be visible on prior-year mammograms (false-negative cases); these breast cancer cases are the basis of this analysis. All cases had CAD evaluation available at the time of cancer diagnosis and on prior mammography studies. Data collected included patient demographics, breast density, palpability, lesion type, mammographic size, CAD marks on current- and prior-year mammograms, needle biopsy method, pathology results (core needle and/or surgical), surgery type, and lesion size. Results: On retrospective review of the mammograms by the staff radiologists, 43 cancers were discovered to be visible on prior-year mammograms. All 43 cancers were masses (mass classification included mass, mass with calcification, and mass with architectural distortion); no pure microcalcifications were identified in this cohort. Mammograms with CAD applied at the time of breast cancer diagnosis were able to detect 79% (34/43) of the cases and 56% (24/43) from mammograms with CAD applied during prior year(s). In heterogeneously dense/extremely dense tissue, CAD marked 79% (27/34) on mammograms taken at the time of diagnosis and 56% (19

  3. Mammogram CAD, hybrid registration and iconic analysis

    NASA Astrophysics Data System (ADS)

    Boucher, A.; Cloppet, F.; Vincent, N.

    2013-03-01

    This paper aims to develop a computer aided diagnosis (CAD) based on a two-step methodology to register and analyze pairs of temporal mammograms. The concept of "medical file", including all the previous medical information on a patient, enables joint analysis of different acquisitions taken at different times, and the detection of significant modifications. The developed registration method aims to superimpose at best the different anatomical structures of the breast. The registration is designed in order to get rid of deformation undergone by the acquisition process while preserving those due to breast changes indicative of malignancy. In order to reach this goal, a referent image is computed from control points based on anatomical features that are extracted automatically. Then the second image of the couple is realigned on the referent image, using a coarse-to-fine approach according to expert knowledge that allows both rigid and non-rigid transforms. The joint analysis detects the evolution between two images representing the same scene. In order to achieve this, it is important to know the registration error limits in order to adapt the observation scale. The approach used in this paper is based on an image sparse representation. Decomposed in regular patterns, the images are analyzed under a new angle. The evolution detection problem has many practical applications, especially in medical images. The CAD is evaluated using recall and precision of differences in mammograms.

  4. Effects of MicroCAD on Learning Fundamental Engineering Graphical Concepts: A Qualitative Study.

    ERIC Educational Resources Information Center

    Leach, James A.; Gull, Randall L.

    1990-01-01

    Students' reactions and performances were examined when taught engineering geometry concepts using a standard microcomputer-aided drafting software package. Two sample groups were compared based on their computer experience. Included are the methodology, data analysis, and conclusions. (KR)

  5. Training a CAD classifier with correlated data

    NASA Astrophysics Data System (ADS)

    Dundar, Murat; Krishnapuram, Balaji; Wolf, Matthias; Lakare, Sarang; Bogoni, Luca; Bi, Jinbo; Rao, R. Bharat

    2007-03-01

    Most methods for classifier design assume that the training samples are drawn independently and identically from an unknown data generating distribution (i.i.d.), although this assumption is violated in several real life problems. Relaxing this i.i.d. assumption, we develop training algorithms for the more realistic situation where batches or sub-groups of training samples may have internal correlations, although the samples from different batches may be considered to be uncorrelated; we also consider the extension to cases with hierarchical--i.e. higher order--correlation structure between batches of training samples. After describing efficient algorithms that scale well to large datasets, we provide some theoretical analysis to establish their validity. Experimental results from real-life Computer Aided Detection (CAD) problems indicate that relaxing the i.i.d. assumption leads to statistically significant improvements in the accuracy of the learned classifier.

  6. Understanding dental CAD/CAM for restorations--the digital workflow from a mechanical engineering viewpoint.

    PubMed

    Tapie, L; Lebon, N; Mawussi, B; Fron Chabouis, H; Duret, F; Attal, J-P

    2015-01-01

    As digital technology infiltrates every area of daily life, including the field of medicine, so it is increasingly being introduced into dental practice. Apart from chairside practice, computer-aided design/computer-aided manufacturing (CAD/CAM) solutions are available for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental solutions can be considered a chain of digital devices and software for the almost automatic design and creation of dental restorations. However, dentists who want to use the technology often do not have the time or knowledge to understand it. A basic knowledge of the CAD/CAM digital workflow for dental restorations can help dentists to grasp the technology and purchase a CAM/CAM system that meets the needs of their office. This article provides a computer-science and mechanical-engineering approach to the CAD/CAM digital workflow to help dentists understand the technology.

  7. Understanding dental CAD/CAM for restorations--the digital workflow from a mechanical engineering viewpoint.

    PubMed

    Tapie, L; Lebon, N; Mawussi, B; Fron Chabouis, H; Duret, F; Attal, J-P

    2015-01-01

    As digital technology infiltrates every area of daily life, including the field of medicine, so it is increasingly being introduced into dental practice. Apart from chairside practice, computer-aided design/computer-aided manufacturing (CAD/CAM) solutions are available for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental solutions can be considered a chain of digital devices and software for the almost automatic design and creation of dental restorations. However, dentists who want to use the technology often do not have the time or knowledge to understand it. A basic knowledge of the CAD/CAM digital workflow for dental restorations can help dentists to grasp the technology and purchase a CAM/CAM system that meets the needs of their office. This article provides a computer-science and mechanical-engineering approach to the CAD/CAM digital workflow to help dentists understand the technology. PMID:25911827

  8. Dental students' preferences and performance in crown design: conventional wax-added versus CAD.

    PubMed

    Douglas, R Duane; Hopp, Christa D; Augustin, Marcus A

    2014-12-01

    The purpose of this study was to evaluate dental students' perceptions of traditional waxing vs. computer-aided crown design and to determine the effectiveness of either technique through comparative grading of the final products. On one of twoidentical tooth preparations, second-year students at one dental school fabricated a wax pattern for a full contour crown; on the second tooth preparation, the same students designed and fabricated an all-ceramic crown using computer-aided design (CAD) and computer-aided manufacturing (CAM) technology. Projects were graded for occlusion and anatomic form by three faculty members. On completion of the projects, 100 percent of the students (n=50) completed an eight-question, five-point Likert scalesurvey, designed to assess their perceptions of and learning associated with the two design techniques. The average grades for the crown design projects were 78.3 (CAD) and 79.1 (wax design). The mean numbers of occlusal contacts were 3.8 (CAD) and 2.9(wax design), which was significantly higher for CAD (p=0.02). The survey results indicated that students enjoyed designing afull contour crown using CAD as compared to using conventional wax techniques and spent less time designing the crown using CAD. From a learning perspective, students felt that they learned more about position and the size/strength of occlusal contacts using CAD. However, students recognized that CAD technology has limits in terms of representing anatomic contours and excursive occlusion compared to conventional wax techniques. The results suggest that crown design using CAD could be considered as an adjunct to conventional wax-added techniques in preclinical fixed prosthodontic curricula.

  9. On the Use of CAD-Native Predicates and Geometry in Surface Meshing

    NASA Technical Reports Server (NTRS)

    Aftosmis, M. J.

    1999-01-01

    Several paradigms for accessing computer-aided design (CAD) geometry during surface meshing for computational fluid dynamics are discussed. File translation, inconsistent geometry engines, and nonnative point construction are all identified as sources of nonrobustness. The paper argues in favor of accessing CAD parts and assemblies in their native format, without translation, and for the use of CAD-native predicates and constructors in surface mesh generation. The discussion also emphasizes the importance of examining the computational requirements for exact evaluation of triangulation predicates during surface meshing.

  10. Project Integration Architecture (PIA) and Computational Analysis Programming Interface (CAPRI) for Accessing Geometry Data from CAD Files

    NASA Technical Reports Server (NTRS)

    Benyo, Theresa L.

    2002-01-01

    Integration of a supersonic inlet simulation with a computer aided design (CAD) system is demonstrated. The integration is performed using the Project Integration Architecture (PIA). PIA provides a common environment for wrapping many types of applications. Accessing geometry data from CAD files is accomplished by incorporating appropriate function calls from the Computational Analysis Programming Interface (CAPRI). CAPRI is a CAD vendor neutral programming interface that aids in acquiring geometry data directly from CAD files. The benefits of wrapping a supersonic inlet simulation into PIA using CAPRI are; direct access of geometry data, accurate capture of geometry data, automatic conversion of data units, CAD vendor neutral operation, and on-line interactive history capture. This paper describes the PIA and the CAPRI wrapper and details the supersonic inlet simulation demonstration.

  11. Fabrication of lithium silicate ceramic veneers with a CAD/CAM approach: a clinical report of cleidocranial dysplasia.

    PubMed

    da Cunha, Leonardo Fernandes; Mukai, Eduardo; Hamerschmitt, Raphael Meneghetti; Correr, Gisele Maria

    2015-05-01

    The fabrication of minimally invasive ceramic veneers remains a challenge for dental restorations involving computer-aided design and computer-aided manufacturing (CAD/CAM). The application of an appropriate CAD/CAM protocol and correlation mode not only simplifies the fabrication of ceramic veneers but also improves the resulting esthetics. Ceramic veneers can restore tooth abnormalities caused by disorders such as cleidocranial dysplasia, enamel hypoplasia, or supernumerary teeth. This report illustrates the fabrication of dental veneers with a new lithium silicate ceramic and the CAD/CAM technique in a patient with cleidocranial dysplasia.

  12. CAD Skills Increased through Multicultural Design Project

    ERIC Educational Resources Information Center

    Clemons, Stephanie

    2006-01-01

    This article discusses how students in a college-entry-level CAD course researched four generations of their family histories and documented cultural and symbolic influences within their family backgrounds. AutoCAD software was then used to manipulate those cultural and symbolic images to create the design for a multicultural area rug. AutoCAD was…

  13. Cool-and Unusual-CAD Applications

    ERIC Educational Resources Information Center

    Calhoun, Ken

    2004-01-01

    This article describes several very useful applications of AutoCAD that may lie outside the normal scope of application. AutoCAD commands used in this article are based on AutoCAD 2000I. The author and his students used a Hewlett Packard 750C DesignJet plotter for plotting. (Contains 5 figures and 5 photos.)

  14. Using AutoCAD for descriptive geometry exercises. in undergraduate structural geology

    NASA Astrophysics Data System (ADS)

    Jacobson, Carl E.

    2001-02-01

    The exercises in descriptive geometry typically utilized in undergraduate structural geology courses are quickly and easily solved using the computer drafting program AutoCAD. The key to efficient use of AutoCAD for descriptive geometry involves taking advantage of User Coordinate Systems, alternative angle conventions, relative coordinates, and other aspects of AutoCAD that may not be familiar to the beginning user. A summary of these features and an illustration of their application to the creation of structure contours for a planar dipping bed provides the background necessary to solve other problems in descriptive geometry with the computer. The ease of the computer constructions reduces frustration for the student and provides more time to think about the principles of the problems.

  15. Student Financing in the Health Professions: Dependence on and Interactions between the Higher Education Act and the Public Health Service Act Financial Aid Programs: A Background Paper. Draft.

    ERIC Educational Resources Information Center

    Advisory Committee on Student Financial Assistance, Washington, DC.

    This paper identifies issues that underlie student financing of education in the health professions in terms of the interrelationships and interactions between financial aid programs under Title IV of the Higher Education Act and Titles VII and VIII of the Public Health Service Act. Section 1 provides background to the issues by describing…

  16. A technique to improve the esthetic aspects of CAD/CAM composite resin restorations.

    PubMed

    Rocca, Giovanni Tommaso; Bonnafous, François; Rizcalla, Nicolas; Krejci, Ivo

    2010-10-01

    Bonded indirect computer-aided design/computer-aided manufacturing (CAD/CAM) restorations are increasingly gaining popularity for the restoration of large defects in posterior teeth. In addition to ceramic blocks, composite resin blocks have been developed. Composite resins blocks may have improved mechanical properties, but have poor esthetics. Thus, an esthetic modification of the restoration after machine milling may be necessary. A step-by-step procedure for the external esthetic layering of a composite CAD/CAM restoration is described. This technique can be used to repair or modify any composite resin restoration.

  17. Drafting Fundamentals. Drafting Module 1. Instructor's Guide.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Instructional Materials Lab.

    This Missouri Vocational Instruction Management System instructor's drafting guide has been keyed to the drafting competency profile developed by state industry and education professionals. The guide contains a cross-reference table of instructional materials. Ten units cover drafting fundamentals: (1) introduction to drafting; (2) general safety;…

  18. Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.

    PubMed

    Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre

    2015-01-01

    As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy. PMID:26734668

  19. Rationale for the Use of CAD/CAM Technology in Implant Prosthodontics

    PubMed Central

    Abduo, Jaafar; Lyons, Karl

    2013-01-01

    Despite the predictable longevity of implant prosthesis, there is an ongoing interest to continue to improve implant prosthodontic treatment and outcomes. One of the developments is the application of computer-aided design and computer-aided manufacturing (CAD/CAM) to produce implant abutments and frameworks from metal or ceramic materials. The aim of this narrative review is to critically evaluate the rationale of CAD/CAM utilization for implant prosthodontics. To date, CAD/CAM allows simplified production of precise and durable implant components. The precision of fit has been proven in several laboratory experiments and has been attributed to the design of implants. Milling also facilitates component fabrication from durable and aesthetic materials. With further development, it is expected that the CAD/CAM protocol will be further simplified. Although compelling clinical evidence supporting the superiority of CAD/CAM implant restorations is still lacking, it is envisioned that CAD/CAM may become the main stream for implant component fabrication. PMID:23690778

  20. Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.

    PubMed

    Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre

    2015-01-01

    As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy.

  1. Integration of a CAD System Into an MDO Framework

    NASA Technical Reports Server (NTRS)

    Townsend, J. C.; Samareh, J. A.; Weston, R. P.; Zorumski, W. E.

    1998-01-01

    NASA Langley has developed a heterogeneous distributed computing environment, called the Framework for Inter-disciplinary Design Optimization, or FIDO. Its purpose has been to demonstrate framework technical feasibility and usefulness for optimizing the preliminary design of complex systems and to provide a working environment for testing optimization schemes. Its initial implementation has been for a simplified model of preliminary design of a high-speed civil transport. Upgrades being considered for the FIDO system include a more complete geometry description, required by high-fidelity aerodynamics and structures codes and based on a commercial Computer Aided Design (CAD) system. This report presents the philosophy behind some of the decisions that have shaped the FIDO system and gives a brief case study of the problems and successes encountered in integrating a CAD system into the FEDO framework.

  2. Tooth-colored CAD/CAM monolithic restorations.

    PubMed

    Reich, S

    2015-01-01

    A monolithic restoration (also known as a full contour restoration) is one that is manufactured from a single material for the fully anatomic replacement of lost tooth structure. Additional staining (followed by glaze firing if ceramic materials are used) may be performed to enhance the appearance of the restoration. For decades, monolithic restoration has been the standard for inlay and partial crown restorations manufactured by both pressing and computer-aided design and manufacturing (CAD/CAM) techniques. A limited selection of monolithic materials is now available for dental crown and bridge restorations. The IDS (2015) provided an opportunity to learn about and evaluate current trends in this field. In addition to new developments, established materials are also mentioned in this article to complete the picture. In line with the strategic focus of the IJCD, the focus here is naturally on CAD/CAM materials. PMID:26110926

  3. Tooth-colored CAD/CAM monolithic restorations.

    PubMed

    Reich, S

    2015-01-01

    A monolithic restoration (also known as a full contour restoration) is one that is manufactured from a single material for the fully anatomic replacement of lost tooth structure. Additional staining (followed by glaze firing if ceramic materials are used) may be performed to enhance the appearance of the restoration. For decades, monolithic restoration has been the standard for inlay and partial crown restorations manufactured by both pressing and computer-aided design and manufacturing (CAD/CAM) techniques. A limited selection of monolithic materials is now available for dental crown and bridge restorations. The IDS (2015) provided an opportunity to learn about and evaluate current trends in this field. In addition to new developments, established materials are also mentioned in this article to complete the picture. In line with the strategic focus of the IJCD, the focus here is naturally on CAD/CAM materials.

  4. A Prototype of CAD/CAM Education in the Community College.

    ERIC Educational Resources Information Center

    Kimmey, James R.

    Drawing upon Elgin Community College's (ECC's) 7-year history of program development and operation, this paper demonstrates how ECC, in cooperation with Northern Illinois Industries, Computervision Corporation, Mazak Corporation, and the Society of Manufacturing Engineers, established a Computer-Aided Design and Drafting/Computer-Aided Machining…

  5. CAD/CAM at a Distance: Assessing the Effectiveness of Web-Based Instruction To Meet Workforce Development Needs. AIR 2000 Annual Forum Paper.

    ERIC Educational Resources Information Center

    Wilkerson, Joyce A.; Elkins, Susan A.

    This qualitative case study assessed web-based instruction in a computer-aided design/computer-assisted manufacturing (CAD/CAM) course designed for workforce development. The study examined students' and instructors' experience in a CAD/CAM course delivered exclusively on the Internet, evaluating course content and delivery, clarity of…

  6. For Drafting Programs--Computer Graphics in Industrial Tech.

    ERIC Educational Resources Information Center

    Sutliff, Ron

    1980-01-01

    Posits that computer-aided drafting and design should be introduced to students in industrial technology programs. Discusses ways the technical educator can get involved in computer graphics to familiarize students with it without a large outlay of money. (JOW)

  7. Extending Engineering Design Graphics Laboratories to Have a CAD/CAM Component: Implementation Issues.

    ERIC Educational Resources Information Center

    Juricic, Davor; Barr, Ronald E.

    1996-01-01

    Reports on a project that extended the Engineering Design Graphics curriculum to include instruction and laboratory experience in computer-aided design, analysis, and manufacturing (CAD/CAM). Discusses issues in project implementation, including introduction of finite element analysis to lower-division students, feasibility of classroom prototype…

  8. Preparing for High Technology: CAD/CAM Programs. Research & Development Series No. 234.

    ERIC Educational Resources Information Center

    Abram, Robert; And Others

    This guide is one of three developed to provide information and resources to assist in planning and developing postsecondary technican training programs in high technology areas. It is specifically intended for vocational-technical educators and planners in the initial stages of planning a specialized training option in computer-aided design (CAD)…

  9. Use of MathCAD in a Pharmacokinetics Course for PharmD Students.

    ERIC Educational Resources Information Center

    Sullivan, Timothy J.

    1992-01-01

    This paper describes the application of the Student Edition of MathCAD as a computational aid in an introductory graduate level pharmacokinetics course. The program allows the student to perform mathematical calculations and analysis on a computer screen. The advantages and disadvantages of this application are discussed. (GLR)

  10. Complete-mouth rehabilitation using a 3D printing technique and the CAD/CAM double scanning method: A clinical report.

    PubMed

    Joo, Han-Sung; Park, Sang-Won; Yun, Kwi-Dug; Lim, Hyun-Pil

    2016-07-01

    According to evolving computer-aided design/computer-aided manufacturing (CAD/CAM) technology, ceramic materials such as zirconia can be used to create fixed dental prostheses for partial removable dental prostheses. Since 3D printing technology was introduced a few years ago, dental applications of this technique have gradually increased. This clinical report presents a complete-mouth rehabilitation using 3D printing and the CAD/CAM double-scanning method.

  11. Complete-mouth rehabilitation using a 3D printing technique and the CAD/CAM double scanning method: A clinical report.

    PubMed

    Joo, Han-Sung; Park, Sang-Won; Yun, Kwi-Dug; Lim, Hyun-Pil

    2016-07-01

    According to evolving computer-aided design/computer-aided manufacturing (CAD/CAM) technology, ceramic materials such as zirconia can be used to create fixed dental prostheses for partial removable dental prostheses. Since 3D printing technology was introduced a few years ago, dental applications of this technique have gradually increased. This clinical report presents a complete-mouth rehabilitation using 3D printing and the CAD/CAM double-scanning method. PMID:26946918

  12. Investigating the effects of majority voting on CAD systems: a LIDC case study

    NASA Astrophysics Data System (ADS)

    Carrazza, Miguel; Kennedy, Brendan; Rasin, Alexander; Furst, Jacob; Raicu, Daniela

    2016-03-01

    Computer-Aided Diagnosis (CAD) systems can provide a second opinion for either identifying suspicious regions on a medical image or predicting the degree of malignancy for a detected suspicious region. To develop a predictive model, CAD systems are trained on low-level image features extracted from image data and the class labels acquired through radiologists' interpretations or a gold standard (e.g., a biopsy). While the opinion of an expert radiologist is still an estimate of the answer, the ground truth may be extremely expensive to acquire. In such cases, CAD systems are trained on input data that contains multiple expert opinions per case with the expectation that the aggregate of labels will closely approximate the ground truth. Using multiple labels to solve this problem has its own challenges because of the inherent label uncertainty introduced by the variability in the radiologists' interpretations. Most CAD systems use majority voting (e.g., average, mode) to handle label uncertainty. This paper investigates the effects that majority voting can have on a CAD system by classifying and analyzing different semantic characteristics supplied with the Lung Image Database Consortium (LIDC) dataset. Using a decision tree based iterative predictive model, we show that majority voting with labels that exhibit certain types of skewed distribution can have a significant negative impact on the performance of a CAD system; therefore, alternative strategies for label integration are required when handling multiple interpretations.

  13. Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

    PubMed

    Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike

    2011-08-01

    The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p < 0.05). Within the limitations of this study, all restorations showed a clinically acceptable marginal accuracy; however, the results suggest that the CAD/CAM systems are more precise than the CAM-only system for the manufacture of four-unit FDPs. PMID:20495937

  14. From Artisanal to CAD-CAM Blocks: State of the Art of Indirect Composites.

    PubMed

    Mainjot, A K; Dupont, N M; Oudkerk, J C; Dewael, T Y; Sadoun, M J

    2016-05-01

    Indirect composites have been undergoing an impressive evolution over the last few years. Specifically, recent developments in computer-aided design-computer-aided manufacturing (CAD-CAM) blocks have been associated with new polymerization modes, innovative microstructures, and different compositions. All these recent breakthroughs have introduced important gaps among the properties of the different materials. This critical state-of-the-art review analyzes the strengths and weaknesses of the different varieties of CAD-CAM composite materials, especially as compared with direct and artisanal indirect composites. Indeed, new polymerization modes used for CAD-CAM blocks-especially high temperature (HT) and, most of all, high temperature-high pressure (HT-HP)-are shown to significantly increase the degree of conversion in comparison with light-cured composites. Industrial processes also allow for the augmentation of the filler content and for the realization of more homogeneous structures with fewer flaws. In addition, due to their increased degree of conversion and their different monomer composition, some CAD-CAM blocks are more advantageous in terms of toxicity and monomer release. Finally, materials with a polymer-infiltrated ceramic network (PICN) microstructure exhibit higher flexural strength and a more favorable elasticity modulus than materials with a dispersed filler microstructure. Consequently, some high-performance composite CAD-CAM blocks-particularly experimental PICNs-can now rival glass-ceramics, such as lithium-disilicate glass-ceramics, for use as bonded partial restorations and crowns on natural teeth and implants. Being able to be manufactured in very low thicknesses, they offer the possibility of developing innovative minimally invasive treatment strategies, such as "no prep" treatment of worn dentition. Current issues are related to the study of bonding and wear properties of the different varieties of CAD-CAM composites. There is also a crucial

  15. Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

    PubMed

    Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike

    2011-08-01

    The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p < 0.05). Within the limitations of this study, all restorations showed a clinically acceptable marginal accuracy; however, the results suggest that the CAD/CAM systems are more precise than the CAM-only system for the manufacture of four-unit FDPs.

  16. Teaching Computer-Aided Design of Fluid Flow and Heat Transfer Engineering Equipment.

    ERIC Educational Resources Information Center

    Gosman, A. D.; And Others

    1979-01-01

    Describes a teaching program for fluid mechanics and heat transfer which contains both computer aided learning (CAL) and computer aided design (CAD) components and argues that the understanding of the physical and numerical modeling taught in the CAL course is essential to the proper implementation of CAD. (Author/CMV)

  17. The Challenging Academic Development (CAD) Collective

    ERIC Educational Resources Information Center

    Peseta, Tai

    2005-01-01

    This article discusses the Challenging Academic Development (CAD) Collective and describes how it came out of a symposium called "Liminality, identity, and hybridity: On the promise of new conceptual frameworks for theorising academic/faculty development." The CAD Collective is and represents a space where people can open up their contexts and…

  18. Increasing productivity of the McAuto CAD/CAE system by user-specific applications programming

    NASA Technical Reports Server (NTRS)

    Plotrowski, S. M.; Vu, T. H.

    1985-01-01

    Significant improvements in the productivity of the McAuto Computer-Aided Design/Computer-Aided Engineering (CAD/CAE) system were achieved by applications programming using the system's own Graphics Interactive Programming language (GRIP) and the interface capabilities with the main computer on which the system resides. The GRIP programs for creating springs, bar charts, finite element model representations and aiding management planning are presented as examples.

  19. Custom hip prostheses by integrating CAD and casting technology

    NASA Astrophysics Data System (ADS)

    Silva, Pedro F.; Leal, Nuno; Neto, Rui J.; Lino, F. Jorge; Reis, Ana

    2012-09-01

    Total Hip Arthroplasty (THA) is a surgical intervention that is being achieving high rates of success, leaving room to research on long run durability, patient comfort and costs reduction. Even so, up to the present, little research has been done to improve the method of manufacturing customized prosthesis. The common customized prostheses are made by full machining. This document presents a different approach methodology which combines the study of medical images, through CAD (Computer Aided Design) software, SLadditive manufacturing, ceramic shell manufacture, precision foundry with Titanium alloys and Computer Aided Manufacturing (CAM). The goal is to achieve the best comfort for the patient, stress distribution and the maximum lifetime of the prosthesis produced by this integrated methodology. The way to achieve this desiderate is to make custom hip prosthesis which are adapted to each patient needs and natural physiognomy. Not only the process is reliable, but also represents a cost reduction comparing to the conventional full machined custom hip prosthesis.

  20. Computer-aided diagnosis in thoracic CT

    NASA Astrophysics Data System (ADS)

    Li, Qiang

    2009-10-01

    Computer-aided diagnosis (CAD) provides a computer output as a "second opinion" in order to assist radiologists in the diagnosis of various diseases on medical images. Currently, a hot topic in CAD is the development of computerized schemes for detection of lung abnormalities, such as lung nodule and interstitial lung disease, in computed tomography (CT) images. The author describes in this article the current status of the CAD schemes for the detection of lung nodules and interstitial lung disease in CT developed by the author and his colleagues at the University of Chicago and Duke University.

  1. [An experimental research on the fabrication of the fused porcelain to CAD/CAM molar crown].

    PubMed

    Dai, Ning; Zhou, Yongyao; Liao, Wenhe; Yu, Qing; An, Tao; Jiao, Yiqun

    2007-02-01

    This paper introduced the fabrication process of the fused porcelain to molar crown with CAD/CAM technology. Firstly, preparation teeth data was retrieved by the 3D-optical measuring system. Then, we have reconstructed the inner surface designed the outer surface shape with the computer aided design software. Finally, the mini high-speed NC milling machine was used to produce the fused porcelain to CAD/CAM molar crown. The result has proved that the fabrication process is reliable and efficient. The dental restoration quality is steady and precise. PMID:17333906

  2. Architectural Drafting. Curriculum Development. Bulletin 1779.

    ERIC Educational Resources Information Center

    Eppler, Thomas

    This teaching guide is designed to aid high school vocational education teachers in teaching a course in architectural drafting for students who plan to become architects, interior designers and decorators, architectural draftspersons, landscape engineers, building contractors, building estimators, real estate persons or appraisers, and others.…

  3. Computer aided detection system for clustered microcalcifications

    PubMed Central

    Ge, Jun; Hadjiiski, Lubomir M.; Sahiner, Berkman; Wei, Jun; Helvie, Mark A.; Zhou, Chuan; Chan, Heang-Ping

    2009-01-01

    We have developed a computer-aided detection (CAD) system to detect clustered microcalcification automatically on full-field digital mammograms (FFDMs) and a CAD system for screen-film mammograms (SFMs). The two systems used the same computer vision algorithms but their false positive (FP) classifiers were trained separately with sample images of each modality. In this study, we compared the performance of the CAD systems for detection of clustered microcalcifications on pairs of FFDM and SFM obtained from the same patient. For case-based performance evaluation, the FFDM CAD system achieved detection sensitivities of 70%, 80%, and 90% at an average FP cluster rate of 0.07, 0.16, and 0.63 per image, compared with an average FP cluster rate of 0.15, 0.38, and 2.02 per image for the SFM CAD system. The difference was statistically significant with the alternative free-response receiver operating characteristic (AFROC) analysis. When evaluated on data sets negative for microcalcification clusters, the average FP cluster rates of the FFDM CAD system were 0.04, 0.11, and 0.33 per image at detection sensitivity level of 70%, 80%, and 90%, compared with an average FP cluster rate of 0.08, 0.14, and 0.50 per image for the SFM CAD system. When evaluated for malignant cases only, the difference of the performance of the two CAD systems was not statistically significant with AFROC analysis. PMID:17264365

  4. Issues of a Computer-Aided Design of Hydraulic Jacks

    NASA Astrophysics Data System (ADS)

    Averchenkov, V. I.; Averchenkov, A. V.; Kolyakinand, V. V.; Orekhov, O. D.

    2016-04-01

    The article deals with the issues of a computer-aided design of hydraulic equipment, namely hydraulic jacks. Design principles of the hydraulic jack CAD system are described. In addition, the possibilities for the system improvement and expansion are considered.

  5. 75 FR 45114 - Rite Aid Corporation; Analysis of Proposed Consent Order to Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-02

    ... Rite Aid Corporation; Analysis of Proposed Consent Order to Aid Public Comment AGENCY: Federal Trade... competition. The attached Analysis to Aid Public Comment describes both the allegations in the draft complaint... invited to submit written comments electronically or in paper form. Comments should refer to ``Rite...

  6. Flexible Concurrency Control for Legacy CAD to Construct Collaborative CAD Environment

    NASA Astrophysics Data System (ADS)

    Cai, Xiantao; Li, Xiaoxia; He, Fazhi; Han, Soonhung; Chen, Xiao

    Collaborative CAD (Co-CAD) systems can be constructed based on either 3D kernel or legacy stand-alone CAD systems, which are typically commercial CAD systems such as CATIA, Pro/E and so on. Most of synchronous Co-CAD systems, especially these based on legacy stand-alone CAD systems, adopt the lock mechanism or the floor control as concurrency controls which are very restrictive and stagnant. A flexible concurrency control method is proposed to support the flexible concurrency control in Co-CAD systems based on legacy stand-alone CAD systems. At first, a model of operation relationship is proposed with special consideration for the concurrency control of these kinds of Co-CAD system. Then two types of data structure, the Collaborative Feature Dependent Graph (Co-FDG) and the Collaborative Feature Operational List (Co-FOL), are presented as the cornerstone of flexible concurrency control. Next a Flexible Concurrency Control Algorithm (FCCA) is proposed. Finally a Selective Undo/Redo Algorithm is proposed which can improve the flexibility of Co-CAD furthermore.

  7. Advances in noninvasive detection of CAD

    SciTech Connect

    Kahn, J.K. )

    1991-04-01

    Advances in the noninvasive detection of myocardial ischemia are increasing our ability to diagnose coronary artery disease (CAD). Tomographic (SPECT) thallium imaging provides better identification of coronary arteries with atherosclerotic narrowing. Increased lung thallium uptake and transient ischemic dilatation of the heart are additional markers of severe CAD. Late thallium imaging, as well as reinjection imaging, provides more accurate identification of myocardial ischemia. Finally, new myocardial imaging agents, such as technetium Tc 99m sestamibi (Cardiolite), should improve detection of CAD by noninvasive methods.10 references.

  8. Engineering Technology Programs Courses Guide for Computer Aided Design and Computer Aided Manufacturing.

    ERIC Educational Resources Information Center

    Georgia Univ., Athens. Div. of Vocational Education.

    This guide describes the requirements for courses in computer-aided design and computer-aided manufacturing (CAD/CAM) that are part of engineering technology programs conducted in vocational-technical schools in Georgia. The guide is organized in five sections. The first section provides a rationale for occupations in design and in production,…

  9. Fabrication of the mandibular implant-supported fixed restoration using CAD/CAM technology: a clinical report.

    PubMed

    Reshad, Mamaly; Cascione, Domenico; Aalam, Alexandre Amir

    2009-11-01

    The mandibular implant-supported fixed restoration is an appropriate treatment choice for patients with inadequate bone volume in the posterior mandible. Computer-aided design/computer-aided manufacturing (CAD/CAM) technology has broadened the scope and application for this treatment option. A milled titanium bar retaining individual all-ceramic zirconium oxide crowns, with composite resin replicating gingival tissues, is recommended as an acceptable variation for this type of prosthesis. An alternative method for fabricating a mandibular implant-supported fixed restoration using CAD/CAM technology is described.

  10. CAD system for footwear design based on whole real 3D data of last surface

    NASA Astrophysics Data System (ADS)

    Song, Wanzhong; Su, Xianyu

    2000-10-01

    Two major parts of application of CAD in footwear design are studied: the development of last surface; computer-aided design of planar shoe-template. A new quasi-experiential development algorithm of last surface based on triangulation approximation is presented. This development algorithm consumes less time and does not need any interactive operation for precisely development compared with other development algorithm of last surface. Based on this algorithm, a software, SHOEMAKERTM, which contains computer aided automatic measurement, automatic development of last surface and computer aide design of shoe-template has been developed.

  11. Mechanical design productivity using CAD graphics - A user's point of view

    NASA Astrophysics Data System (ADS)

    Boltz, R. J.; Avery, J. T., Jr.

    1985-02-01

    The present investigation is concerned with the mechanical design productivity resulting from the use of Computer-Aided Design (CAD) graphics as a design tool. The considered studies had been conducted by a company which is involved in the design, development, and manufacture of government and defense products. Attention is given to CAD graphics for mechanical design, productivity, an overall productivity assessment, the use of CAD graphics for basic mechanical design, productivity in engineering-related areas, and an overall engineering productivity assessment. The investigation shows that there was no appreciable improvement in productivity with respect to basic mechanical design. However, rather substantial increases could be realized in productivity for engineering-related activities.

  12. CADS:Cantera Aerosol Dynamics Simulator.

    SciTech Connect

    Moffat, Harry K.

    2007-07-01

    This manual describes a library for aerosol kinetics and transport, called CADS (Cantera Aerosol Dynamics Simulator), which employs a section-based approach for describing the particle size distributions. CADS is based upon Cantera, a set of C++ libraries and applications that handles gas phase species transport and reactions. The method uses a discontinuous Galerkin formulation to represent the particle distributions within each section and to solve for changes to the aerosol particle distributions due to condensation, coagulation, and nucleation processes. CADS conserves particles, elements, and total enthalpy up to numerical round-off error, in all of its formulations. Both 0-D time dependent and 1-D steady state applications (an opposing-flow flame application) have been developed with CADS, with the initial emphasis on developing fundamental mechanisms for soot formation within fires. This report also describes the 0-D application, TDcads, which models a time-dependent perfectly stirred reactor.

  13. Project Hill-Climb: Drafting and Design in Motion

    ERIC Educational Resources Information Center

    Crowl, William F.

    2008-01-01

    This article describes the Hill-Climb project of a second level Computer-Aided Drafting and Design (CADD) class. The author primarily designed the activity to increase student understanding of the assembly drawing process and its components. The emphasis on problem solving adds a dimension that can aid students in their other classes as well. By…

  14. The CAD-EGS Project: Using CAD Geometrics in EGS4

    SciTech Connect

    Langeveld, Willy G.J.

    2002-03-28

    The objective of the CAD-EGS project is to provide a way to use a CAD system to create 3D geometries for use within EGS4. In this report, we describe an approach based on an intermediate file, written out by the CAD system, that is read by an EGS4 user code designed for the purpose. A prototype solution was implemented using a commonly used CAD system and the Virtual Reality Modeling Language (VRML) as an intermediate file format. We report results from the prototype, and discuss various problems arising from both the approach and the particular choices made.

  15. A critically appraised topic review of computer-aided design/computer-aided machining of removable partial denture frameworks.

    PubMed

    Lang, Lisa A; Tulunoglu, Ibrahim

    2014-01-01

    A critically appraised topic (CAT) review is presented about the use of computer-aided design (CAD)/computer-aided machining (CAM) removable partial denture (RPD) frameworks. A systematic search of the literature supporting CAD/CAM RPD systems revealed no randomized clinical trials, hence the CAT review was performed. A PubMed search yielded 9 articles meeting the inclusion criteria. Each article was characterized by study design and level of evidence. No clinical outcomes research has been published on the use of CAD/CAM RPDs. Low levels of evidence were found in the available literature. Clinical research studies are needed to determine the efficacy of this treatment modality.

  16. Potential reasons for differences in CAD effectiveness evaluated using laboratory and clinical studies

    NASA Astrophysics Data System (ADS)

    He, Xin; Samuelson, Frank; Zeng, Rongping; Sahiner, Berkman

    2015-03-01

    Research studies have investigated a number of factors that may impact the performance assessment of computer aided detection (CAD) effectiveness, such as the inherent design of the CAD, the image and reader samples, and the assessment methods. In this study, we focused on the effect of prevalence on cue validity (co-occurrence of cue and signal) and learning as potentially important factors in CAD assessment. For example, the prevalence of cases with breast cancer is around 50% in laboratory CAD studies, which is 100 times higher than that in breast cancer screening. Although ROC is prevalence-independent, an observer's use of CAD involves tasks that are more complicated than binary classification, including: search, detection, classification, cueing and learning. We developed models to investigate the potential impact of prevalence on cue validity and the learning of cue validity tasks. We hope this work motivates new studies that investigate previously under-explored factors involved in image interpretation with a new modality in its assessment.

  17. Software aids plant management

    SciTech Connect

    Winiger, T. )

    1992-11-01

    This paper reports that for most utilities, computer aided engineering (CAE) systems are currently used for operating plant support rather than new plant design particularly for nuclear plant maintenance. For nuclear power generating utilities, switching to a modern, integrated CAE information system can offer significant benefits. During the last decade, however, most engineering automation in the power generation industry focused on computer-aided drafting and stand-alone engineering applications. An integrated CAE system can be a useful too, assisting engineers with many engineering and operational activities. It also can be used to manage the massive amount of information created throughout the life of a plant.

  18. An image database management system for conducting CAD research

    NASA Astrophysics Data System (ADS)

    Gruszauskas, Nicholas; Drukker, Karen; Giger, Maryellen L.

    2007-03-01

    The development of image databases for CAD research is not a trivial task. The collection and management of images and their related metadata from multiple sources is a time-consuming but necessary process. By standardizing and centralizing the methods in which these data are maintained, one can generate subsets of a larger database that match the specific criteria needed for a particular research project in a quick and efficient manner. A research-oriented management system of this type is highly desirable in a multi-modality CAD research environment. An online, webbased database system for the storage and management of research-specific medical image metadata was designed for use with four modalities of breast imaging: screen-film mammography, full-field digital mammography, breast ultrasound and breast MRI. The system was designed to consolidate data from multiple clinical sources and provide the user with the ability to anonymize the data. Input concerning the type of data to be stored as well as desired searchable parameters was solicited from researchers in each modality. The backbone of the database was created using MySQL. A robust and easy-to-use interface for entering, removing, modifying and searching information in the database was created using HTML and PHP. This standardized system can be accessed using any modern web-browsing software and is fundamental for our various research projects on computer-aided detection, diagnosis, cancer risk assessment, multimodality lesion assessment, and prognosis. Our CAD database system stores large amounts of research-related metadata and successfully generates subsets of cases that match the user's desired search criteria.

  19. Advanced Geologic Modeling Using CAD and Unstructured Meshes

    NASA Astrophysics Data System (ADS)

    Melnikova, Y.; Jacquemyn, C.; Osman, H.; Gorman, G.; Hampson, G.; Jackson, M.

    2015-12-01

    Capturing complex, multiscale geologic heterogeneity in subsurface flow models is challenging. Surface-based modeling (SBM) offers an alternative approach to conventional grid-based methods. In SBM, all geologic features that impact the distribution of material properties, such as porosity and permeability, are modeled as volumes bounded by surfaces. Within these volumes, termed geologic domains, the material properties are constant. A typical model contains numerous such domains. The surfaces have parametric, grid-free representation which, in principle, allows for unlimited complexity, since no resolution is implied at the stage of modeling and features of any scale can be included. We demonstrate a method to create stochastic, surface-based models using computer aided design (CAD) and efficiently discretise them for flow simulation. The surfaces are represented using non-uniform, rational B-splines (NURBS), and processed in a CAD environment employing Boolean operations. We show examples of fluvial channels, fracture networks and scour events. Cartesian-like grids are not able to capture the complex geometries in these models without using excessively large numbers of grid blocks. Unstructured meshes can more efficiently approximate the geometries. However, high aspect ratio features and varying curvatures present challenges for algorithms to produce quality, unstructured meshes without excessive user interaction. We contribute an automated integrated workflow that processes the input geometry created in the CAD environment, creates the final model, and discretises it with a quality tetrahedral mesh. For computational efficiency, we use a geometry-adaptive mesh that distributes the element density and size in accordance with the geometrical complexity of the model. We show examples of finite-element flow simulations of the resulting geologic models. The new approach has broad application in modeling subsurface flow.

  20. Bridging CAGD knowledge into CAD/CG applications: Mathematical theories as stepping stones of innovations

    NASA Astrophysics Data System (ADS)

    Gobithaasan, R. U.; Miura, Kenjiro T.; Hassan, Mohamad Nor

    2014-07-01

    Computer Aided Geometric Design (CAGD) which surpasses the underlying theories of Computer Aided Design (CAD) and Computer Graphics (CG) has been taught in a number of Malaysian universities under the umbrella of Mathematical Sciences' faculty/department. On the other hand, CAD/CG is taught either under the Engineering or Computer Science Faculty. Even though CAGD researchers/educators/students (denoted as contributors) have been enriching this field of study by means of article/journal publication, many fail to convert the idea into constructive innovation due to the gap that occurs between CAGD contributors and practitioners (engineers/product/designers/architects/artists). This paper addresses this issue by advocating a number of technologies that can be used to transform CAGD contributors into innovators where immediate impact in terms of practical application can be experienced by the CAD/CG practitioners. The underlying principle of solving this issue is twofold. First would be to expose the CAGD contributors on ways to turn mathematical ideas into plug-ins and second is to impart relevant CAGD theories to CAD/CG to practitioners. Both cases are discussed in detail and the final section shows examples to illustrate the importance of turning mathematical knowledge into innovations.

  1. Comparison of CAD-CAM and hand made sockets for PTB prostheses.

    PubMed

    Köhler, P; Lindh, L; Netz, P

    1989-04-01

    The aim of the present study was to compare sockets for below-knee (BK) prostheses made by Computer Aided Design-Computer Aided Manufacture (CAD-CAM) to those made by hand. The patients in the study were provided with two prostheses each, which apart from the sockets, were identical. One socket was made by the CAD-CAM technique developed at the Bioengineering Centre, Roehampton, University College London and one was made by hand at the OT-Centre, Stockholm, Sweden. The results were based on investigation of eight unilateral below-knee amputees evaluating their own sockets by Visual Analogous Scale with respect to comfort, pressure, and pain. The sockets were evaluated on seven occasions, at two tests, on delivery, after use every second day for six days and every second week for two weeks. All CAD-CAM sockets except one had to be changed once as compared to the hand made of which only two had to be changed. As to comfort it could not be demonstrated that there was any significant difference between the two types of sockets and both types were well accepted by all patients. Differences in pressure and pain were rarely reported. There were obvious differences between the two types of socket with respect to height, width, and inner surface configuration. The authors feel that CAD-CAM will in the near future be an excellent tool for design and manufacture of prosthetic sockets.

  2. Basic Drafting. Revised.

    ERIC Educational Resources Information Center

    Schertz, Karen

    This introductory module on drafting includes the technical content and tasks necessary for a student to be employed in an entry-level drafting occupation. The module contains 18 instructional units that cover the following topics: introduction to drafting; tools and equipment; supplies and materials; sketching; scales; drawing format; lettering;…

  3. General Drafting. Technical Manual.

    ERIC Educational Resources Information Center

    Department of the Army, Washington, DC.

    The manual provides instructional guidance and reference material in the principles and procedures of general drafting and constitutes the primary study text for personnel in drafting as a military occupational specialty. Included is information on drafting equipment and its use; line weights, conventions and formats; lettering; engineering charts…

  4. Performance evaluation of NASA/KSC CAD/CAE graphics local area network

    NASA Technical Reports Server (NTRS)

    Zobrist, George

    1988-01-01

    This study had as an objective the performance evaluation of the existing CAD/CAE graphics network at NASA/KSC. This evaluation will also aid in projecting planned expansions, such as the Space Station project on the existing CAD/CAE network. The objectives were achieved by collecting packet traffic on the various integrated sub-networks. This included items, such as total number of packets on the various subnetworks, source/destination of packets, percent utilization of network capacity, peak traffic rates, and packet size distribution. The NASA/KSC LAN was stressed to determine the useable bandwidth of the Ethernet network and an average design station workload was used to project the increased traffic on the existing network and the planned T1 link. This performance evaluation of the network will aid the NASA/KSC network managers in planning for the integration of future workload requirements into the existing network.

  5. Modelling polymer draft gears

    NASA Astrophysics Data System (ADS)

    Wu, Qing; Yang, Xiangjian; Cole, Colin; Luo, Shihui

    2016-09-01

    This paper developed a new and simple approach to model polymer draft gears. Two types of polymer draft gears were modelled and compared with experimental data. Impact characteristics, in-train characteristics and frequency responses of these polymer draft gears were studied and compared with those of a friction draft gear. The impact simulations show that polymer draft gears can withstand higher impact speeds than the friction draft gear. Longitudinal train dynamics simulations show that polymer draft gears have significantly longer deflections than friction draft gears in normal train operations. The maximum draft gear working velocities are lower than 0.2 m/s, which are significantly lower than the impact velocities during shunting operations. Draft gears' in-train characteristics are similar to their static characteristics but are very different from their impact characteristics; this conclusion has also been reached from frequency response simulations. An analysis of gangway bridge plate failures was also conducted and it was found that they were caused by coupler angling behaviour and long draft gear deflections.

  6. Next Generation CAD/CAM/CAE Systems

    NASA Technical Reports Server (NTRS)

    Noor, Ahmed K. (Compiler); Malone, John B. (Compiler)

    1997-01-01

    This document contains presentations from the joint UVA/NASA Workshop on Next Generation CAD/CAM/CAE Systems held at NASA Langley Research Center in Hampton, Virginia on March 18-19, 1997. The presentations focused on current capabilities and future directions of CAD/CAM/CAE systems, aerospace industry projects, and university activities related to simulation-based design. Workshop attendees represented NASA, commercial software developers, the aerospace industry, government labs, and academia. The workshop objectives were to assess the potential of emerging CAD/CAM/CAE technology for use in intelligent simulation-based design and to provide guidelines for focused future research leading to effective use of CAE systems for simulating the entire life cycle of aerospace systems.

  7. cadDX Operon of Streptococcus salivarius 57.I▿

    PubMed Central

    Chen, Yi-Ywan M.; Feng, C. W.; Chiu, C. F.; Burne, Robert A.

    2008-01-01

    A CadDX system that confers resistance to Cd2+ and Zn2+ was identified in Streptococcus salivarius 57.I. Unlike with other CadDX systems, the expression of the cad promoter was negatively regulated by CadX, and the repression was inducible by Cd2+ and Zn2+, similar to what was found for CadCA systems. The lower G+C content of the S. salivarius cadDX genes suggests acquisition by horizontal gene transfer. PMID:18165364

  8. cadDX operon of Streptococcus salivarius 57.I.

    PubMed

    Chen, Yi-Ywan M; Feng, C W; Chiu, C F; Burne, Robert A

    2008-03-01

    A CadDX system that confers resistance to Cd(2+) and Zn(2+) was identified in Streptococcus salivarius 57.I. Unlike with other CadDX systems, the expression of the cad promoter was negatively regulated by CadX, and the repression was inducible by Cd(2+) and Zn(2+), similar to what was found for CadCA systems. The lower G+C content of the S. salivarius cadDX genes suggests acquisition by horizontal gene transfer. PMID:18165364

  9. Application of computer-aided dispatch in law enforcement: An introductory planning guide

    NASA Technical Reports Server (NTRS)

    Sohn, R. L.; Gurfield, R. M.; Garcia, E. A.; Fielding, J. E.

    1975-01-01

    A set of planning guidelines for the application of computer-aided dispatching (CAD) to law enforcement is presented. Some essential characteristics and applications of CAD are outlined; the results of a survey of systems in the operational or planning phases are summarized. Requirements analysis, system concept design, implementation planning, and performance and cost modeling are described and demonstrated with numerous examples. Detailed descriptions of typical law enforcement CAD systems, and a list of vendor sources, are given in appendixes.

  10. The effect of CO2 and Nd:YAP lasers on CAD/CAM Ceramics: SEM, EDS and thermal studies

    PubMed Central

    Fornaini, Carlo; Rocca, Jean Paul; Muhammad, Omid H; Medioni, Etienne; Cucinotta, Annamaria; Brulat-Bouchard, Nathalie

    2016-01-01

    Background and aims: The objective of this study was to investigate the interaction of infrared laser light on Computer Aided Design and Computer Aided Manufacturing (CAD/CAM) ceramic surfaces. Material and Methods: Sixty CAD/CAM ceramic discs were prepared and divided into two different groups: lithiumdisilicate ceramic (IPSe.maxCADs) and Zirconia ceramic (IPSe.maxZirCADs). The laser irradiation was performed on graphite and non-graphite surfaces with a Carbon Dioxide laser at 5W and 10W power in continuous mode (CW mode) and with Neodymium Yttrium Aluminum Perovskite (Nd:YAP) laser at 10W. Surface textures and compositions were examined using Scanning Electron Microscopy (SEM), and Energy Dispersive Spectroscopy (EDS). Thermal elevation was measured by thermocouple during laser irradiation. Results: The SEM observation showed a rough surface plus cracks and fissures on CO2 10W samples and melting areas in Nd:YAP samples; moreover, with CO2 5W smooth and shallow surfaces were observed. EDS analysis revealed that laser irradiation does not result in modifications of the chemical composition even if minor changes in the atomic mass percentage of the components were registered. Thermocouple showed several thermal changes during laser irradiation. Conclusion: CO2 and Nd:YAP lasers modify CAD/CAM ceramic surface without chemical composition modifications. PMID:27141152

  11. Computer Aided Design: Instructional Manual. The North Dakota High Technology Mobile Laboratory Project.

    ERIC Educational Resources Information Center

    Cheng, Wan-Lee

    This instructional manual contains 12 learning activity packets for use in a workshop in computer-aided design and drafting (CADD). The lessons cover the following topics: introduction to computer graphics and computer-aided design/drafting; coordinate systems; advance space graphics hardware configuration and basic features of the IBM PC…

  12. Draft Whole-Genome Sequences of 25 Salmonella enterica Strains Representing 24 Serovars

    PubMed Central

    Brumwell, Stephanie L.; Lingohr, Erika J.; Ahmad, Aaminah; Blimkie, Travis M.; Kogan, Benjamin A.; Pilsworth, Jessica; Rehman, Muhammad A.; Schleicher, Krista L.; Shanmugaraj, Jenitta; Kropinski, Andrew M.; Nash, John H. E.

    2016-01-01

    We report the draft genome sequences of 25 Salmonella enterica strains representing 24 different serotypes, many of which were not available in public repositories during our selection process. These draft genomes will provide useful reference for the genetic variation between serotypes and aid in the development of molecular typing tools. PMID:26941156

  13. From Artisanal to CAD-CAM Blocks: State of the Art of Indirect Composites.

    PubMed

    Mainjot, A K; Dupont, N M; Oudkerk, J C; Dewael, T Y; Sadoun, M J

    2016-05-01

    Indirect composites have been undergoing an impressive evolution over the last few years. Specifically, recent developments in computer-aided design-computer-aided manufacturing (CAD-CAM) blocks have been associated with new polymerization modes, innovative microstructures, and different compositions. All these recent breakthroughs have introduced important gaps among the properties of the different materials. This critical state-of-the-art review analyzes the strengths and weaknesses of the different varieties of CAD-CAM composite materials, especially as compared with direct and artisanal indirect composites. Indeed, new polymerization modes used for CAD-CAM blocks-especially high temperature (HT) and, most of all, high temperature-high pressure (HT-HP)-are shown to significantly increase the degree of conversion in comparison with light-cured composites. Industrial processes also allow for the augmentation of the filler content and for the realization of more homogeneous structures with fewer flaws. In addition, due to their increased degree of conversion and their different monomer composition, some CAD-CAM blocks are more advantageous in terms of toxicity and monomer release. Finally, materials with a polymer-infiltrated ceramic network (PICN) microstructure exhibit higher flexural strength and a more favorable elasticity modulus than materials with a dispersed filler microstructure. Consequently, some high-performance composite CAD-CAM blocks-particularly experimental PICNs-can now rival glass-ceramics, such as lithium-disilicate glass-ceramics, for use as bonded partial restorations and crowns on natural teeth and implants. Being able to be manufactured in very low thicknesses, they offer the possibility of developing innovative minimally invasive treatment strategies, such as "no prep" treatment of worn dentition. Current issues are related to the study of bonding and wear properties of the different varieties of CAD-CAM composites. There is also a crucial

  14. Web-Based Learning in the Computer-Aided Design Curriculum.

    ERIC Educational Resources Information Center

    Sung, Wen-Tsai; Ou, S. C.

    2002-01-01

    Applies principles of constructivism and virtual reality (VR) to computer-aided design (CAD) curriculum, particularly engineering, by integrating network, VR and CAD technologies into a Web-based learning environment that expands traditional two-dimensional computer graphics into a three-dimensional real-time simulation that enhances user…

  15. Management of CAD/CAM information: Key to improved manufacturing productivity

    NASA Technical Reports Server (NTRS)

    Fulton, R. E.; Brainin, J.

    1984-01-01

    A key element to improved industry productivity is effective management of CAD/CAM information. To stimulate advancements in this area, a joint NASA/Navy/Industry project designated Integrated Programs for Aerospace-Vehicle Design (IPAD) is underway with the goal of raising aerospace industry productivity through advancement of technology to integrate and manage information involved in the design and manufacturing process. The project complements traditional NASA/DOD research to develop aerospace design technology and the Air Force's Integrated Computer-Aided Manufacturing (ICAM) program to advance CAM technology. IPAD research is guided by an Industry Technical Advisory Board (ITAB) composed of over 100 repesentatives from aerospace and computer companies. The IPAD accomplishments to date in development of requirements and prototype software for various levels of company-wide CAD/CAM data management are summarized and plans for development of technology for management of distributed CAD/CAM data and information required to control future knowledge-based CAD/CAM systems are discussed.

  16. True Concurrent Thermal Engineering Integrating CAD Model Building with Finite Element and Finite Difference Methods

    NASA Technical Reports Server (NTRS)

    Panczak, Tim; Ring, Steve; Welch, Mark

    1999-01-01

    Thermal engineering has long been left out of the concurrent engineering environment dominated by CAD (computer aided design) and FEM (finite element method) software. Current tools attempt to force the thermal design process into an environment primarily created to support structural analysis, which results in inappropriate thermal models. As a result, many thermal engineers either build models "by hand" or use geometric user interfaces that are separate from and have little useful connection, if any, to CAD and FEM systems. This paper describes the development of a new thermal design environment called the Thermal Desktop. This system, while fully integrated into a neutral, low cost CAD system, and which utilizes both FEM and FD methods, does not compromise the needs of the thermal engineer. Rather, the features needed for concurrent thermal analysis are specifically addressed by combining traditional parametric surface based radiation and FD based conduction modeling with CAD and FEM methods. The use of flexible and familiar temperature solvers such as SINDA/FLUINT (Systems Improved Numerical Differencing Analyzer/Fluid Integrator) is retained.

  17. PACS-Based Computer-Aided Detection and Diagnosis

    NASA Astrophysics Data System (ADS)

    Huang, H. K. (Bernie); Liu, Brent J.; Le, Anh HongTu; Documet, Jorge

    The ultimate goal of Picture Archiving and Communication System (PACS)-based Computer-Aided Detection and Diagnosis (CAD) is to integrate CAD results into daily clinical practice so that it becomes a second reader to aid the radiologist's diagnosis. Integration of CAD and Hospital Information System (HIS), Radiology Information System (RIS) or PACS requires certain basic ingredients from Health Level 7 (HL7) standard for textual data, Digital Imaging and Communications in Medicine (DICOM) standard for images, and Integrating the Healthcare Enterprise (IHE) workflow profiles in order to comply with the Health Insurance Portability and Accountability Act (HIPAA) requirements to be a healthcare information system. Among the DICOM standards and IHE workflow profiles, DICOM Structured Reporting (DICOM-SR); and IHE Key Image Note (KIN), Simple Image and Numeric Report (SINR) and Post-processing Work Flow (PWF) are utilized in CAD-HIS/RIS/PACS integration. These topics with examples are presented in this chapter.

  18. Education and Training Packages for CAD/CAM.

    ERIC Educational Resources Information Center

    Wright, I. C.

    1986-01-01

    Discusses educational efforts in the fields of Computer Assisted Design and Manufacturing (CAD/CAM). Describes two educational training initiatives underway in the United Kingdom, one of which is a resource materials package for teachers of CAD/CAM at the undergraduate level, and the other a training course for managers of CAD/CAM systems. (TW)

  19. A CAD (Classroom Assessment Design) of a Computer Programming Course

    ERIC Educational Resources Information Center

    Hawi, Nazir S.

    2012-01-01

    This paper presents a CAD (classroom assessment design) of an entry-level undergraduate computer programming course "Computer Programming I". CAD has been the product of a long experience in teaching computer programming courses including teaching "Computer Programming I" 22 times. Each semester, CAD is evaluated and modified for the subsequent…

  20. 3D-WOVEN FIBER-REINFORCED COMPOSITE FOR CAD/CAM DENTAL APPLICATION

    PubMed Central

    Petersen, Richard; Liu, Perng-Ru

    2016-01-01

    Three-dimensional (3D)-woven noncrimp fiber-reinforced composite (FRC) was tested for mechanical properties in the two principal directions of the main XY plane and compared to different Computer-Aided-Design/Computer-Aided-Machining (CAD/CAM) Dental Materials. The Dental Materials included ceramic with Vitablock Mark II®, ProCAD®, InCeram® Spinel, InCeram® Alumina and InCeram® Zirconia in addition to a resin-based 3M Corp. Paradigm® particulate-filled composite. Alternate material controls included Coors 300 Alumina Ceramic and a tungsten carbide 22% cobalt cermet. The 3D-woven FRC was vacuum assisted resin transfer molding processed as a one-depth-thickness ~19-mm preform with a vinyl-ester resin and cut into blocks similar to the commercial CAD/CAM Dental Materials. Mechanical test samples prepared for a flexural three-point span length of 10.0 mm were sectioned for minimum-depth cuts to compare machinability and fracture resistance between groups. 3D-woven FRC improved mechanical properties with significant statistical differences over all CAD/CAM Dental Materials and Coors Alumina Ceramic for flexural strength (p<0.001), resilience (p<0.05), work of fracture (p<0.001), strain energy release (p<0.05), critical stress intensity factor (p<0.001) and strain (p<0.001). PMID:27642198

  1. Mathematics for Drafting.

    ERIC Educational Resources Information Center

    Clary, Joseph R.; Nery, Karen P.

    This set of three modules was designed for use primarily to help teach and reinforce the basic mathematics skills in drafting classes. The modules are based on the needs of drafting students in beginning courses as determined by a survey of teachers across North Carolina. Each module consists of basic information and examples and problem sheets…

  2. Basic Drafting: Book One.

    ERIC Educational Resources Information Center

    Davis, Ronald; And Others

    The first of a two-book course in drafting, this manual consists of 13 topics in the following units: introduction to drafting, general safety, basic tools and lines, major equipment, applying for a job, media, lettering, reproduction, drawing sheet layout, architect's scale usage, civil engineer's scale usage, mechanical engineer's scale usage,…

  3. ProperCAD: A portable object-oriented parallel environment for VLSI CAD

    NASA Technical Reports Server (NTRS)

    Ramkumar, Balkrishna; Banerjee, Prithviraj

    1993-01-01

    Most parallel algorithms for VLSI CAD proposed to date have one important drawback: they work efficiently only on machines that they were designed for. As a result, algorithms designed to date are dependent on the architecture for which they are developed and do not port easily to other parallel architectures. A new project under way to address this problem is described. A Portable object-oriented parallel environment for CAD algorithms (ProperCAD) is being developed. The objectives of this research are (1) to develop new parallel algorithms that run in a portable object-oriented environment (CAD algorithms using a general purpose platform for portable parallel programming called CARM is being developed and a C++ environment that is truly object-oriented and specialized for CAD applications is also being developed); and (2) to design the parallel algorithms around a good sequential algorithm with a well-defined parallel-sequential interface (permitting the parallel algorithm to benefit from future developments in sequential algorithms). One CAD application that has been implemented as part of the ProperCAD project, flat VLSI circuit extraction, is described. The algorithm, its implementation, and its performance on a range of parallel machines are discussed in detail. It currently runs on an Encore Multimax, a Sequent Symmetry, Intel iPSC/2 and i860 hypercubes, a NCUBE 2 hypercube, and a network of Sun Sparc workstations. Performance data for other applications that were developed are provided: namely test pattern generation for sequential circuits, parallel logic synthesis, and standard cell placement.

  4. DFE workbench: a CAD integrated DFE tool

    NASA Astrophysics Data System (ADS)

    Man, Elena; Diez-Campo, Juan E.; Roche, Thomas

    2002-02-01

    Because of the emergent legislation (e.g. WEEE and EOLV), environmental standards (e.g. ISO 14000) and a shift in consumer opinion toward environmentally superior products, there is an increased need for CAD integrated Design for Environment tools to assist the designer in the development of environmentally superior products (ESP). Implementing Design for the Environment practices is an extremely effective strategy, as it is widely believed that 95% of development costs are determined at this stage. Many methodologies and tools have been developed to perform environmental analysis; however, many existing methodologies are inadequately integrated in the design process. This paper addresses these problems and presents a CAD integrated DFE tool that has been under development in the authors' institutes for the last number of years.

  5. IPAD 2: Advances in Distributed Data Base Management for CAD/CAM

    NASA Technical Reports Server (NTRS)

    Bostic, S. W. (Compiler)

    1984-01-01

    The Integrated Programs for Aerospace-Vehicle Design (IPAD) Project objective is to improve engineering productivity through better use of computer-aided design and manufacturing (CAD/CAM) technology. The focus is on development of technology and associated software for integrated company-wide management of engineering information. The objectives of this conference are as follows: to provide a greater awareness of the critical need by U.S. industry for advancements in distributed CAD/CAM data management capability; to present industry experiences and current and planned research in distributed data base management; and to summarize IPAD data management contributions and their impact on U.S. industry and computer hardware and software vendors.

  6. Clinical and Laboratory Steps for Fabricating a Complete-Arch Fixed Prosthesis Using CAD/CAM.

    PubMed

    Keerthi, Senthil; Proussaefs, Periklis; Lozada, Jaime

    2015-01-01

    The fabrication of a full-arch maxillary prosthesis has been associated with several prosthetic complications and difficulties. Even though it has been reported that phonetics, esthetics, and proper lip support are difficult to achieve, there is a scarcity in the literature regarding the clinical and laboratory procedures necessary to minimize these complications. This article provides clinical and laboratory steps that may enable the clinician to achieve more predictable restorative results when using computer-aided design/computer-assisted manufacture (CAD/CAM) to fabricate a full-arch maxillary implant-supported prosthesis. The technique presented here describes the use of an implant-retained diagnostic wax-up that is subsequently duplicated to an interim polymethylmethacrylate prosthesis using CAD/CAM before fabricating the definitive restoration.

  7. Multiple platform application of 3D CAD PIC simulations in pulsed power

    SciTech Connect

    Peratt, A.L.; Mostrom, M.A.

    1995-12-31

    With the availability of 80--125 MHz microprocessors, the methodology developed for the simulation of problems in pulsed power and plasma physics on modern day supercomputers is now amenable to application on a wide range of platforms including laptops and workstations. While execution speeds with these processors do not match those of large scale computing machines, resources such as computer-aided-design (CAD) and graphical analysis codes are available to automate simulation setup and process data. This paper reports on the adaptation of IVORY, a three-dimensional, fully-electromagnetic, particle-in-cell simulation code, to this platform independent CAD environment. The primary purpose of this talk is to demonstrate how rapidly a pulsed power/plasma problem can be scoped out by an experimenter on a dedicated workstation. Demonstrations include a magnetically insulated transmission line, power flow in a graded insulator stack, a relativistic klystron oscillator, and the dynamics of a coaxial thruster for space applications.

  8. Development of personalized annuloplasty rings: combination of CT images and CAD-CAM tools.

    PubMed

    Díaz Lantada, Andrés; Valle-Fernández, Raquel Del; Morgado, Pilar Lafont; Muñoz-García, Julio; Muñoz Sanz, José Luis; Munoz-Guijosa, Juan Manuel; Otero, Javier Echávarri

    2010-02-01

    Although the use of personalized annuloplasty rings manufactured for each patient according to the size and morphology of their valve complex could be beneficial for the treatment of mitral insufficiency, this possibility has been limited for reasons of time-lines and costs as well as for design and manufacturing difficulties, as has been the case with other personalized implant and prosthetic developments. However, the present quality of medical image capture equipment together with the benefits to be had from computer-aided design and manufacturing technologies (CAD-CAM) and the capabilities furnished by rapid prototyping technologies, present new opportunities for a personalized response to the development of implants and prostheses, the social impact of which could turn out to be highly positive. This paper sets out a personalized development of an annuloplasty ring based on the combined use of information from medical imaging, from CAD-CAM design programs and prototype manufacture using rapid prototyping technologies.

  9. Development of personalized annuloplasty rings: combination of CT images and CAD-CAM tools.

    PubMed

    Díaz Lantada, Andrés; Valle-Fernández, Raquel Del; Morgado, Pilar Lafont; Muñoz-García, Julio; Muñoz Sanz, José Luis; Munoz-Guijosa, Juan Manuel; Otero, Javier Echávarri

    2010-02-01

    Although the use of personalized annuloplasty rings manufactured for each patient according to the size and morphology of their valve complex could be beneficial for the treatment of mitral insufficiency, this possibility has been limited for reasons of time-lines and costs as well as for design and manufacturing difficulties, as has been the case with other personalized implant and prosthetic developments. However, the present quality of medical image capture equipment together with the benefits to be had from computer-aided design and manufacturing technologies (CAD-CAM) and the capabilities furnished by rapid prototyping technologies, present new opportunities for a personalized response to the development of implants and prostheses, the social impact of which could turn out to be highly positive. This paper sets out a personalized development of an annuloplasty ring based on the combined use of information from medical imaging, from CAD-CAM design programs and prototype manufacture using rapid prototyping technologies. PMID:19826955

  10. Low-Dose CT Screening for Lung Cancer: Computer-aided Detection of Missed Lung Cancers.

    PubMed

    Liang, Mingzhu; Tang, Wei; Xu, Dong Ming; Jirapatnakul, Artit C; Reeves, Anthony P; Henschke, Claudia I; Yankelevitz, David

    2016-10-01

    Purpose To update information regarding the usefulness of computer-aided detection (CAD) systems with a focus on the most critical category, that of missed cancers at earlier imaging, for cancers that manifest as a solid nodule. Materials and Methods By using a HIPAA-compliant institutional review board-approved protocol where informed consent was obtained, 50 lung cancers that manifested as a solid nodule on computed tomographic (CT) scans in annual rounds of screening (time 1) were retrospectively identified that could, in retrospect, be identified on the previous CT scans (time 0). Four CAD systems were compared, which were referred to as CAD 1, CAD 2, CAD 3, and CAD 4. The total number of accepted CAD-system-detected nodules at time 0 was determined by consensus of two radiologists and the number of CAD-system-detected nodules that were rejected by the radiologists was also documented. Results At time 0 when all the cancers had been missed, CAD system detection rates for the cancers were 56%, 70%, 68%, and 60% (κ = 0.45) for CAD systems 1, 2, 3, and 4, respectively. At time 1, the rates were 74%, 82%, 82%, and 78% (κ = 0.32), respectively. The average diameter of the 50 cancers at time 0 and time 1 was 4.8 mm and 11.4 mm, respectively. The number of CAD-system-detected nodules that were rejected per CT scan for CAD systems 1-4 at time 0 was 7.4, 1.7, 0.6, and 4.5 respectively. Conclusion CAD systems detected up to 70% of lung cancers that were not detected by the radiologist but failed to detect about 20% of the lung cancers when they were identified by the radiologist, which suggests that CAD may be useful in the role of second reader. (©) RSNA, 2016.

  11. CAD Integration : new optical design possibilities

    NASA Astrophysics Data System (ADS)

    Haumonte, Jean-Baptiste; Venturino, Jean-Claude

    2005-09-01

    The development of optical design and analysis tools in a CAD software can help to optimise the design, size and performance of tomorrow's consumer products. While optics was still held back by software limitations, CAD programs were moving forward in leaps and bounds, improving manufacturing technologies and making it possible to design and produce highly innovative and sophisticated products. The problem was that in the past, 'traditional' optical design programs were only able to simulate spherical and aspherical lenses, meaning that the optical designers were limited to designing systems which were a series of imperfect lenses, each one correcting the last. That is why OPTIS has created the first optical design program to be fully integrated into a CAD program. The technology is available from OPTIS in an integrated SOLIDWORKS or CATIA V5 version. Users of this software can reduce the number of lenses needed in a system. Designers will now have access to complex surfaces such as NURBS meaning they will now be able to define free shape progressive lenses and even improve on optical performances using fewer lenses. This revolutionary technology will allow mechanical designers to work on optical systems and to share information with optical designers for the first time. Previously not possible in a CAD program you may now determine all the optical performances of any optical system, providing first order and third order performances, sequential and non-sequential ray-tracing, wavefront surfaces, point spread function, MTF, spot-diagram, using real optical surfaces and guaranteeing the mechanical precision necessary for an optical system.

  12. Digital breast tomosynthesis: application of 2D digital mammography CAD to detection of microcalcification clusters on planar projection image

    NASA Astrophysics Data System (ADS)

    Samala, Ravi K.; Chan, Heang-Ping; Lu, Yao; Hadjiiski, Lubomir; Wei, Jun; Helvie, Mark

    2015-03-01

    Computer-aided detection (CAD) has the potential to aid radiologists in detection of microcalcification clusters (MCs). CAD for digital breast tomosynthesis (DBT) can be developed by using the reconstructed volume, the projection views or other derivatives as input. We have developed a novel method of generating a single planar projection (PPJ) image from a regularized DBT volume to emphasize the high contrast objects such as microcalcifications while removing the anatomical background and noise. In this work, we adapted a CAD system developed for digital mammography (CADDM) to the PPJ image and compared its performance with our CAD system developed for DBT volumes (CADDBT) in the same set of cases. For microcalcification detection in the PPJ image using the CADDM system, the background removal preprocessing step designed for DM was not needed. The other methods and processing steps in the CADDM system were kept without modification while the parameters were optimized with a training set. The linear discriminant analysis classifier using cluster based features was retrained to generate a discriminant score to be used as decision variable. For view-based FROC analysis, at 80% sensitivity, an FP rate of 1.95/volume and 1.54/image were achieved, respectively, for CADDBT and CADDM in an independent test set. At a threshold of 1.2 FPs per image or per DBT volume, the nonparametric analysis of the area under the FROC curve shows that the optimized CADDM for PPJ is significantly better than CADDBT. However, the performance of CADDM drops at higher sensitivity or FP rate, resulting in similar overall performance between the two CAD systems. The higher sensitivity of the CADDM in the low FP rate region and vice versa for the CADDBT indicate that a joint CAD system combining detection in the DBT volume and the PPJ image has the potential to increase the sensitivity and reduce the FP rate.

  13. Ergonomics Perspective in Agricultural Research: A User-Centred Approach Using CAD and Digital Human Modeling (DHM) Technologies

    NASA Astrophysics Data System (ADS)

    Patel, Thaneswer; Sanjog, J.; Karmakar, Sougata

    2016-09-01

    Computer-aided Design (CAD) and Digital Human Modeling (DHM) (specialized CAD software for virtual human representation) technologies endow unique opportunities to incorporate human factors pro-actively in design development. Challenges of enhancing agricultural productivity through improvement of agricultural tools/machineries and better human-machine compatibility can be ensured by adoption of these modern technologies. Objectives of present work are to provide the detailed scenario of CAD and DHM applications in agricultural sector; and finding out means for wide adoption of these technologies for design and development of cost-effective, user-friendly, efficient and safe agricultural tools/equipment and operator's workplace. Extensive literature review has been conducted for systematic segregation and representation of available information towards drawing inferences. Although applications of various CAD software have momentum in agricultural research particularly for design and manufacturing of agricultural equipment/machinery, use of DHM is still at its infancy in this sector. Current review discusses about reasons of less adoption of these technologies in agricultural sector and steps to be taken for their wide adoption. It also suggests possible future research directions to come up with better ergonomic design strategies for improvement of agricultural equipment/machines and workstations through application of CAD and DHM.

  14. Ergonomics Perspective in Agricultural Research: A User-Centred Approach Using CAD and Digital Human Modeling (DHM) Technologies

    NASA Astrophysics Data System (ADS)

    Patel, Thaneswer; Sanjog, J.; Karmakar, Sougata

    2016-06-01

    Computer-aided Design (CAD) and Digital Human Modeling (DHM) (specialized CAD software for virtual human representation) technologies endow unique opportunities to incorporate human factors pro-actively in design development. Challenges of enhancing agricultural productivity through improvement of agricultural tools/machineries and better human-machine compatibility can be ensured by adoption of these modern technologies. Objectives of present work are to provide the detailed scenario of CAD and DHM applications in agricultural sector; and finding out means for wide adoption of these technologies for design and development of cost-effective, user-friendly, efficient and safe agricultural tools/equipment and operator's workplace. Extensive literature review has been conducted for systematic segregation and representation of available information towards drawing inferences. Although applications of various CAD software have momentum in agricultural research particularly for design and manufacturing of agricultural equipment/machinery, use of DHM is still at its infancy in this sector. Current review discusses about reasons of less adoption of these technologies in agricultural sector and steps to be taken for their wide adoption. It also suggests possible future research directions to come up with better ergonomic design strategies for improvement of agricultural equipment/machines and workstations through application of CAD and DHM.

  15. CT colonography with computer-aided detection: recognizing the causes of false-positive reader results.

    PubMed

    Trilisky, Igor; Wroblewski, Kristen; Vannier, Michael W; Horne, John M; Dachman, Abraham H

    2014-01-01

    Computed tomography (CT) colonography is a screening modality used to detect colonic polyps before they progress to colorectal cancer. Computer-aided detection (CAD) is designed to decrease errors of detection by finding and displaying polyp candidates for evaluation by the reader. CT colonography CAD false-positive results are common and have numerous causes. The relative frequency of CAD false-positive results and their effect on reader performance on the basis of a 19-reader, 100-case trial shows that the vast majority of CAD false-positive results were dismissed by readers. Many CAD false-positive results are easily disregarded, including those that result from coarse mucosa, reconstruction, peristalsis, motion, streak artifacts, diverticulum, rectal tubes, and lipomas. CAD false-positive results caused by haustral folds, extracolonic candidates, diminutive lesions (<6 mm), anal papillae, internal hemorrhoids, varices, extrinsic compression, and flexural pseudotumors are almost always recognized and disregarded. The ileocecal valve and tagged stool are common sources of CAD false-positive results associated with reader false-positive results. Nondismissable CAD soft-tissue polyp candidates larger than 6 mm are another common cause of reader false-positive results that may lead to further evaluation with follow-up CT colonography or optical colonoscopy. Strategies for correctly evaluating CAD polyp candidates are important to avoid pitfalls from common sources of CAD false-positive results.

  16. Advanced layout parameter extraction and detailed timing simulation of GaAs gate arrays in MagiCAD

    NASA Astrophysics Data System (ADS)

    Buchs, Kevin J.; Rowlands, David O.; Prentice, Jeffrey A.; Gilbert, Barry K.

    1990-10-01

    This paper discusses the features and function of three specific computer aided design tools contained in the Mayo Graphical Integrated Computer Aided Design (MagiCAD) system a complete electronic CAD software package optimized for the design and layout of semicustom (i. e. gate array) Gallium Arsenide (GaAs) integrated circuits. The first design tool the Layout Extractor processes data from placed and routed gate arrays. The Extractor verifies that the layout represents the original logic design and calculates the parasitic capacitance of the individual wiring segments in the logic nets after they have been routed. The capacitance information as calculated by the Layout Extractor is significant in GaAs work since the delay in signals traveling through the routing is often much greater than the delay of the signals traveling through the gates themselves. Once the capacitance data has been processed by the Layout Extractor it becomes available to the second CAD tool discussed here the MagiCAD timing simulation program Sting. Sting a digital event-driven simulator depends on user generation of C language-like behavioral models for all root nodes to be simulated. Through the use of delays calculated by the Extractor from the actual routing and input pin capacitances Sting assures that the entire chip design will operate correctly at the intended clock rate. The third design tool is a set of programs allowing simulation of the electromagnetic behavior of integrated circuit packages circuit

  17. Architectural Drafting, Drafting 2: 9255.04.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    The course covers the basic fundamentals of architectural drafting and is not intended to delve into the more advanced phases of architecture. The student is presented with standards and procedures, and will become proficient in layout of floor plans, electrical plans, roof construction, foundation plans, typical wall construction, plot plans, and…

  18. Cluster: Drafting. Course: Introduction to Technical Drafting.

    ERIC Educational Resources Information Center

    Sanford - Lee County Schools, NC.

    The set of 10 units is designed for use with an instructor as an introduction to technical drafting, and is also keyed to other texts. Each unit contains several task packages specifying prerequisites, rationale for learning, objectives, learning activities to be supervised by the instructor, and learning practice. The units cover: drafting…

  19. Aeronautical Drafting, Drafting 3: 9257.02.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    Intended for students interested in the aircraft and missile field of engineering and drafting, the course covers fundamentals, working drawings, and auxiliary views and sections that are related to this field. Considered advanced training, a prerequisite for the course is mastery of the skills indicated in Electrical and Electronic…

  20. HIV / AIDS

    MedlinePlus

    ... Marketing Share this: Main Content Area Understanding HIV/AIDS AIDS was first reported in the United States in ... and has since become a major worldwide epidemic. AIDS is caused by the human immunodeficiency virus, or ...

  1. Developmental tendency of hearing aid semi-auto-manufacturing

    NASA Astrophysics Data System (ADS)

    Jarng, Soon Suck; Lee, Yanbo

    2009-12-01

    What's the developmental tendency of the hearing aid manufacturing in the future? The answer is a rapid production or/and CAD/CAM technology. The new technology is quite different from the conventional manufacturing method. This article shows the differences between the 2 types of approach in detail, and analyzes these differences. The authors figure out where and how to cut an ear shell impression that will give help to the hearing aid manufacturing process, and make the CAD/CAM method to fit for the Asians' ears.

  2. Drafting: Current Trends and Future Practices

    ERIC Educational Resources Information Center

    Jensen, C.

    1976-01-01

    Various research findings are reported on drafting trends which the author feels should be incorporated into teaching drafting: (1) true position and geometric tolerancing, (2) decimal and metric dimensioning, (3) functional drafting, (4) automated drafting, and (5) drawing reproductions. (BP)

  3. Microfilming for Drafting Students

    ERIC Educational Resources Information Center

    Bass, Ronald E.

    1972-01-01

    If you have a 35mm camera, an enlarger or filmstrip projector, and developing equipment you can introduce your drafting students to one of the processes used in the newly emerging field of technical communication.'' (Editor)

  4. Model-Based Engineering and Manufacturing CAD/CAM Benchmark

    SciTech Connect

    Domm, T.D.; Underwood, R.S.

    1999-04-26

    The Benehmark Project was created from a desire to identify best practices and improve the overall efficiency and performance of the Y-12 Plant's systems and personnel supprting the manufacturing mission. The mission of the benchmark team was to search out industry leaders in manufacturing and evaluate lheir engineering practices and processes to determine direction and focus fm Y-12 modmizadon efforts. The companies visited included several large established companies and anew, small, high-tech machining firm. As a result of this efforL changes are recommended that will enable Y-12 to become a more responsive cost-effective manufacturing facility capable of suppordng the needs of the Nuclear Weapons Complex (NW@) and Work Fw Others into the 21' century. The benchmark team identified key areas of interest, both focused and gencml. The focus arm included Human Resources, Information Management, Manufacturing Software Tools, and Standarda/ Policies and Practices. Areas of general interest included Inhstructure, Computer Platforms and Networking, and Organizational Structure. The method for obtaining the desired information in these areas centered on the creation of a benchmark questionnaire. The questionnaire was used throughout each of the visits as the basis for information gathering. The results of this benchmark showed that all companies are moving in the direction of model-based engineering and manufacturing. There was evidence that many companies are trying to grasp how to manage current and legacy data. In terms of engineering design software tools, the companies contacted were using both 3-D solid modeling and surfaced Wire-frame models. The manufacturing computer tools were varie4 with most companies using more than one software product to generate machining data and none currently performing model-based manufacturing (MBM) ftom a common medel. The majority of companies were closer to identifying or using a single computer-aided design (CAD) system than a

  5. Direct composite resin layering techniques for creating lifelike CAD/CAM-fabricated composite resin veneers and crowns.

    PubMed

    LeSage, Brian

    2014-07-01

    Direct composite resin layering techniques preserve sound tooth structure and improve function and esthetics. However, intraoral placement techniques present challenges involving isolation, contamination, individual patient characteristics, and the predictability of restorative outcomes. Computer-aided design and computer-aided manufacturing (CAD/CAM) restorations enable dentists to better handle these variables and provide durable restorations in an efficient and timely manner; however, milled restorations may appear monochromatic and lack proper esthetic characteristics. For these reasons, an uncomplicated composite resin layering restoration technique can be used to combine the benefits of minimally invasive direct restorations and the ease and precision of indirect CAD/CAM restorations. Because most dentists are familiar with and skilled at composite resin layering, the use of such a technique can provide predictable and highly esthetic results. This article describes the layered composite resin restoration technique.

  6. Direct composite resin layering techniques for creating lifelike CAD/CAM-fabricated composite resin veneers and crowns.

    PubMed

    LeSage, Brian

    2014-07-01

    Direct composite resin layering techniques preserve sound tooth structure and improve function and esthetics. However, intraoral placement techniques present challenges involving isolation, contamination, individual patient characteristics, and the predictability of restorative outcomes. Computer-aided design and computer-aided manufacturing (CAD/CAM) restorations enable dentists to better handle these variables and provide durable restorations in an efficient and timely manner; however, milled restorations may appear monochromatic and lack proper esthetic characteristics. For these reasons, an uncomplicated composite resin layering restoration technique can be used to combine the benefits of minimally invasive direct restorations and the ease and precision of indirect CAD/CAM restorations. Because most dentists are familiar with and skilled at composite resin layering, the use of such a technique can provide predictable and highly esthetic results. This article describes the layered composite resin restoration technique. PMID:24680167

  7. Lung partitioning for x-ray CAD applications

    NASA Astrophysics Data System (ADS)

    Annangi, Pavan; Raja, Anand

    2011-03-01

    Partitioning the inside region of lung into homogeneous regions becomes a crucial step in any computer-aided diagnosis applications based on chest X-ray. The ribs, air pockets and clavicle occupy major space inside the lung as seen in the chest x-ray PA image. Segmenting the ribs and clavicle to partition the lung into homogeneous regions forms a crucial step in any CAD application to better classify abnormalities. In this paper we present two separate algorithms to segment ribs and the clavicle bone in a completely automated way. The posterior ribs are segmented based on Phase congruency features and the clavicle is segmented using Mean curvature features followed by Radon transform. Both the algorithms work on the premise that the presentation of each of these anatomical structures inside the left and right lung has a specific orientation range within which they are confined to. The search space for both the algorithms is limited to the region inside the lung, which is obtained by an automated lung segmentation algorithm that was previously developed in our group. Both the algorithms were tested on 100 images of normal and patients affected with Pneumoconiosis.

  8. Coupling Photon Monte Carlo Simulation and CAD Software. Application to X-ray Nondestructive Evaluation

    NASA Astrophysics Data System (ADS)

    Tabary, J.; Glière, A.

    A Monte Carlo radiation transport simulation program, EGS Nova, and a Computer Aided Design software, BRL-CAD, have been coupled within the framework of Sindbad, a Nondestructive Evaluation (NDE) simulation system. In its current status, the program is very valuable in a NDE laboratory context, as it helps simulate the images due to the uncollided and scattered photon fluxes in a single NDE software environment, without having to switch to a Monte Carlo code parameters set. Numerical validations show a good agreement with EGS4 computed and published data. As the program's major drawback is the execution time, computational efficiency improvements are foreseen.

  9. Management of CAD/CAM information: Key to improved manufacturing productivity

    NASA Technical Reports Server (NTRS)

    Fulton, R. E.; Brainin, J.

    1984-01-01

    A key element to improved industry productivity is effective management of CAD/CAM information. To stimulate advancements in this area, a joint NASA/Navy/industry project designated Intergrated Programs for Aerospace-Vehicle Design (IPAD) is underway with the goal of raising aerospace industry productivity through advancement of technology to integrate and manage information involved in the design and manufacturing process. The project complements traditional NASA/DOD research to develop aerospace design technology and the Air Force's Integrated Computer-Aided Manufacturing (ICAM) program to advance CAM technology. IPAD research is guided by an Industry Technical Advisory Board (ITAB) composed of over 100 representatives from aerospace and computer companies.

  10. Additive CAD/CAM process for dental prostheses.

    PubMed

    Silva, Nelson R F A; Witek, Lukasz; Coelho, Paulo G; Thompson, Van P; Rekow, Elizabeth D; Smay, Jim

    2011-02-01

    This article describes the evolution of a computer-aided design/computer-aided manufacturing (CAD/CAM) process where ceramic paste is deposited in a layer-by-layer sequence using a computer numerical control machine to build up core and fixed partial denture (FPD) structures (robocasting). Al(2)O(3) (alumina) or ZrO(2) (Y-TZP) are blended into a 0.8% aqueous solution of ammonium polyacrylate in a ratio of approximately 1:1 solid:liquid. A viscosifying agent, hydroxypropyl methylcellulose, is added to a concentration of 1% in the liquid phase, and then a counter polyelectrolyte is added to gel the slurry. There are two methods for robocasting crown structures (cores or FPD framework). One is for the core to be printed using zirconia ink without support materials, in which the stereolithography (STL) file is inverted (occlusal surface resting on a flat substrate) and built. The second method uses a fugitive material composed of carbon black codeposited with the ceramic material. During the sintering process, the carbon black is removed. There are two key challenges to successful printing of ceramic crowns by the robocasting technique. First is the development of suitable materials for printing, and second is the design of printing patterns for assembly of the complex geometry required for a dental restoration. Robocasting has room for improvement. Current development involves enhancing the automation of nozzle alignment for accurate support material deposition and better fidelity of the occlusal surface. An accompanying effort involves calculation of optimal support structures to yield the best geometric results and minimal material usage.

  11. Model-Based Engineering and Manufacturing CAD/CAM Benchmark.

    SciTech Connect

    Domm, T.C.; Underwood, R.S.

    1999-10-13

    The Benchmark Project was created from a desire to identify best practices and improve the overall efficiency and performance of the Y-12 Plant's systems and personnel supporting the manufacturing mission. The mission of the benchmark team was to search out industry leaders in manufacturing and evaluate their engineering practices and processes to determine direction and focus for Y-12 modernization efforts. The companies visited included several large established companies and a new, small, high-tech machining firm. As a result of this effort, changes are recommended that will enable Y-12 to become a more modern, responsive, cost-effective manufacturing facility capable of supporting the needs of the Nuclear Weapons Complex (NWC) into the 21st century. The benchmark team identified key areas of interest, both focused and general. The focus areas included Human Resources, Information Management, Manufacturing Software Tools, and Standards/Policies and Practices. Areas of general interest included Infrastructure, Computer Platforms and Networking, and Organizational Structure. The results of this benchmark showed that all companies are moving in the direction of model-based engineering and manufacturing. There was evidence that many companies are trying to grasp how to manage current and legacy data. In terms of engineering design software tools, the companies contacted were somewhere between 3-D solid modeling and surfaced wire-frame models. The manufacturing computer tools were varied, with most companies using more than one software product to generate machining data and none currently performing model-based manufacturing (MBM) from a common model. The majority of companies were closer to identifying or using a single computer-aided design (CAD) system than a single computer-aided manufacturing (CAM) system. The Internet was a technology that all companies were looking to either transport information more easily throughout the corporation or as a conduit for

  12. Costs incurred by applying computer-aided design/computer-aided manufacturing techniques for the reconstruction of maxillofacial defects.

    PubMed

    Rustemeyer, Jan; Melenberg, Alex; Sari-Rieger, Aynur

    2014-12-01

    This study aims to evaluate the additional costs incurred by using a computer-aided design/computer-aided manufacturing (CAD/CAM) technique for reconstructing maxillofacial defects by analyzing typical cases. The medical charts of 11 consecutive patients who were subjected to the CAD/CAM technique were considered, and invoices from the companies providing the CAD/CAM devices were reviewed for every case. The number of devices used was significantly correlated with cost (r = 0.880; p < 0.001). Significant differences in mean costs were found between cases in which prebent reconstruction plates were used (€3346.00 ± €29.00) and cases in which they were not (€2534.22 ± €264.48; p < 0.001). Significant differences were also obtained between the costs of two, three and four devices, even when ignoring the cost of reconstruction plates. Additional fees provided by statutory health insurance covered a mean of 171.5% ± 25.6% of the cost of the CAD/CAM devices. Since the additional fees provide financial compensation, we believe that the CAD/CAM technique is suited for wide application and not restricted to complex cases. Where additional fees/funds are not available, the CAD/CAM technique might be unprofitable, so the decision whether or not to use it remains a case-to-case decision with respect to cost versus benefit.

  13. Evolution of Geometric Sensitivity Derivatives from Computer Aided Design Models

    NASA Technical Reports Server (NTRS)

    Jones, William T.; Lazzara, David; Haimes, Robert

    2010-01-01

    The generation of design parameter sensitivity derivatives is required for gradient-based optimization. Such sensitivity derivatives are elusive at best when working with geometry defined within the solid modeling context of Computer-Aided Design (CAD) systems. Solid modeling CAD systems are often proprietary and always complex, thereby necessitating ad hoc procedures to infer parameter sensitivity. A new perspective is presented that makes direct use of the hierarchical associativity of CAD features to trace their evolution and thereby track design parameter sensitivity. In contrast to ad hoc methods, this method provides a more concise procedure following the model design intent and determining the sensitivity of CAD geometry directly to its respective defining parameters.

  14. The ergonomics of computer aided design within advanced manufacturing technology.

    PubMed

    John, P A

    1988-03-01

    Many manufacturing companies have now awakened to the significance of computer aided design (CAD), although the majority of them have only been able to purchase computerised draughting systems of which only a subset produce direct manufacturing data. Such companies are moving steadily towards the concept of computer integrated manufacture (CIM), and this demands CAD to address more than draughting. CAD architects are thus having to rethink the basic specification of such systems, although they typically suffer from an insufficient understanding of the design task and have consequently been working with inadequate specifications. It is at this fundamental level that ergonomics has much to offer, making its contribution by encouraging user-centred design. The discussion considers the relationships between CAD and: the design task; the organisation and people; creativity; and artificial intelligence. It finishes with a summary of the contribution of ergonomics.

  15. Use of CAD output to guide the intelligent display of digital mammograms

    NASA Astrophysics Data System (ADS)

    Bloomquist, Aili K.; Yaffe, Martin J.; Mawdsley, Gordon E.; Morgan, Trevor; Rico, Dan; Jong, Roberta A.

    2003-05-01

    For digital mammography to be efficient, methods are needed to choose an initial default image presentation that maximizes the amount of relevant information perceived by the radiologist and minimizes the amount of time spent adjusting the image display parameters. The purpose of this work is to explore the possibility of using the output of computer aided detection (CAD) software to guide image enhancement and presentation. A set of 16 digital mammograms with lesions of known pathology was used to develop and evaluate an enhancement and display protocol to improve the initial softcopy presentation of digital mammograms. Lesions were identified by CAD and the DICOM structured report produced by the CAD program was used to determine what enhancement algorithm should be applied in the identified regions of the image. An improved version of contrast limited adaptive histogram equalization (CLAHE) is used to enhance calcifications. For masses, the image is first smoothed using a non-linear diffusion technique; subsequently, local contrast is enhanced with a method based on morphological operators. A non-linear lookup table is automatically created to optimize the contrast in the regions of interest (detected lesions) without losing the context of the periphery of the breast. The effectiveness of the enhancement will be compared with the default presentation of the images using a forced choice preference study.

  16. Effect of CAD on radiologists' detection of lung nodules on thoracic CT scans: observer performance study

    NASA Astrophysics Data System (ADS)

    Sahiner, Berkman; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Shi, Jiazheng; Cascade, Philip N.; Kazerooni, Ella A.; Zhou, Chuan; Wei, Jun; Chughtai, Aamer R.; Poopat, Chad; Song, Thomas; Nojkova, Jadranka S.; Frank, Luba; Attili, Anil

    2007-03-01

    The purpose of this study was to evaluate the effect of computer-aided diagnosis (CAD) on radiologists' performance for the detection of lung nodules on thoracic CT scans. Our computer system was designed using an independent training set of 94 CT scans in our laboratory. The data set for the observer performance study consisted of 48 CT scans. Twenty scans were collected from patient files at the University of Michigan, and 28 scans by the Lung Imaging Database Consortium (LIDC). All scans were read by multiple experienced thoracic radiologists to determine the true nodule locations, defined as any region identified by one or more expert radiologists as containing a nodule larger than 3 mm in diameter. Eighteen CT examinations were nodule-free, while the remaining 30 CT examinations contained a total of 73 nodules having a median size of 5.5 mm (range 3.0-36.4 mm). Four other study radiologists read the CT scans first without and then with CAD, and provided likelihood of nodule ratings for suspicious regions. Two of the study radiologists were fellowship trained in cardiothoracic radiology, and two were cardiothoracic radiology fellows. Freeresponse receiver-operating characteristic (FROC) curves were used to compare the two reading conditions. The computer system had a sensitivity of 79% (58/73) with an average of 4.9 marks per normal scan (88/18). Jackknife alternative FROC (JAFROC) analysis indicated that the improvement with CAD was statistically significant (p=0.03).

  17. A combined fuzzy AHP-simulation approach to CAD software selection

    NASA Astrophysics Data System (ADS)

    Ayağ, Zeki

    2010-10-01

    In this paper, a combined approach, where the fuzzy analytic hierarchy process (AHP) and simulation come together, is presented to select the best computer-aided design (CAD) software out of the available options in the market. The fuzzy AHP is used due to the vagueness and uncertainty of the judgements of a decision maker(s), because the crisp pair-wise comparison in the conventional AHP seems to be insufficient and imprecise to capture the right judgements of the decision maker(s). In this study, first the fuzzy AHP is used to reduce a possible number of alternatives for the CAD system to an acceptable level for further study, simulation analysis. Secondly, a simulation generator as an integrated part of the fuzzy AHP is used to try the remaining alternatives, on the generated model of a real-life product organisation in which the final alternative will be used. The results of simulation experiments are obtained, and then evaluated to reach to the ultimate CAD alternative.

  18. 76 FR 570 - Draft Guidance for Industry and Food and Drug Administration Staff; Establishing the Performance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-05

    ..., plasma, and blood. These devices are used to aid in the diagnosis of Lyme disease. This document does not... detection of antibodies to Borrelia burgdorferi. These devices are used to aid in the diagnosis of Lyme disease. This draft guidance is not final nor is it in effect at this time. DATES: Although you...

  19. A constitution for AIDS.

    PubMed

    Koshy, L M

    1996-01-15

    The Indian Health Organization projected the number of deaths per day due to AIDS by the year 2000 at 10,000. An interdisciplinary international conference was held in New Delhi to draft an international law governing the issues related to AIDS. Human freedom and public health policies are the most affected by this disease. In the absence of an international AIDS law, judicial verdicts set precedents and could have serious ramifications. A participant from the John Marshall Law School, Chicago, suggested that instead of making new laws, the existing ones from the colonial past should be repealed. This includes Section 377 of the Indian Penal Code, which provides criminal sanctions against those who indulge in unnatural relations with man, woman, or animal. Penalizing homosexuality will only perpetuate clandestine relations and spread the virus into their families. Another participant seconded this motion stating that even a sex worker must be protected from abuse and indignity. The National AIDS Control Organization responded to the criticism that the government had not utilized all the World Bank funds allocated for anti-AIDS projects. The trends of the epidemic were the most important indicators not just the numbers. In Manipur and Mizoram, infection was almost entirely due to injecting drug use. The Saheli project undertaken in the red-light areas of Bombay encompassed brothel owners and prostitutes, which could be replicated in other areas. Because existing government policies were focusing on prevention, there was no protection of an HIV-infected individual's privacy, one participant from Madras stated. The confidentiality issue was also echoed by a US participant. The New Delhi Declaration and Action Plan on HIV/AIDS was also discussed. It forbids discrimination in employment, education, housing, health care, social security, travel, and marital and reproductive rights. Providing sterile needles and ensuring the safety of the blood supply were other concerns

  20. Computer Assisted Drafting (CNC) Drawings. Drafting Module 6. Instructor's Guide.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Instructional Materials Lab.

    This Missouri Vocational Instruction Management System instructor's drafting guide has been keyed to the drafting competency profile developed by state industry and education professionals. This unit contains information on computer-assisted drafting drawings. The guide contains a cross-reference table of instructional materials and 20 worksheets.…

  1. Computer-aided detection as a decision assistant in chest radiography

    NASA Astrophysics Data System (ADS)

    Samulski, Maurice R. M.; Snoeren, Peter R.; Platel, Bram; van Ginneken, Bram; Hogeweg, Laurens; Schaefer-Prokop, Cornelia; Karssemeijer, Nico

    2011-03-01

    Background. Contrary to what may be expected, finding abnormalities in complex images like pulmonary nodules in chest radiographs is not dominated by time-consuming search strategies but by an almost immediate global interpretation. This was already known in the nineteen-seventies from experiments with briefly flashed chest radiographs. Later on, experiments with eye-trackers showed that abnormalities attracted the attention quite fast but often without further reader actions. Prolonging one's search seldom leads to newly found abnormalities and may even increase the chance of errors. The problem of reading chest radiographs is therefore not dominated by finding the abnormalities, but by interpreting them. Hypothesis. This suggests that readers could benefit from computer-aided detection (CAD) systems not so much by their ability to prompt potential abnormalities, but more from their ability to 'interpret' the potential abnormalities. In this paper, this hypothesis was investigated by an observer experiment. Experiment. In one condition, the traditional CAD condition, the most suspicious CAD locations were shown to the subjects, without telling them the levels of suspiciousness according to CAD. In the other condition, interactive CAD condition, levels of suspiciousness were given, but only when readers requested them at specified locations. These two conditions focus on decreasing search errors and decision errors, respectively. Results of reading without CAD were also recorded. Six subjects, all non-radiologists, read 223 chest radiographs in both conditions. CAD results were obtained from the OnGuard 5.0 system developed by Riverain Medical (Miamisburg, Ohio). Results. The observer data were analyzed by Location Response Operating Characteristic analysis (LROC). It was found that: 1) With the aid of CAD, the performance is significantly better than without CAD; 2) The performance with interactive CAD is significantly better than with traditional CAD at low false

  2. Full-mouth rehabilitation with monolithic CAD/CAM-fabricated hybrid and all-ceramic materials: A case report and 3-year follow up.

    PubMed

    Selz, Christian F; Vuck, Alexander; Guess, Petra C

    2016-02-01

    Esthetic full-mouth rehabilitation represents a great challenge for clinicians and dental technicians. Computer-aided design/ computer-assisted manufacture (CAD/CAM) technology and novel ceramic materials in combination with adhesive cementation provide a reliable, predictable, and economic workflow. Polychromatic feldspathic CAD/CAM ceramics that are specifically designed for anterior indications result in superior esthetics, whereas novel CAD/CAM hybrid ceramics provide sufficient fracture resistance and adsorption of the occlusal load in posterior areas. Screw-retained monolithic CAD/CAM lithium disilicate crowns (ie, hybrid abutment crowns) represent a reliable and time- and cost-efficient prosthetic implant solution. This case report details a CAD/CAM approach to the full-arch rehabilitation of a 65-year-old patient with toothand implant-supported restorations and provides an overview of the applied CAD/CAM materials and the utilized chairside intraoral scanner. The esthetics, functional occlusion, and gingival and peri-implant tissues remained stable over a follow-up period of 3 years. No signs of fractures within the restorations were observed.

  3. Increasing cancer detection yield of breast MRI using a new CAD scheme of mammograms

    NASA Astrophysics Data System (ADS)

    Tan, Maxine; Aghaei, Faranak; Hollingsworth, Alan B.; Stough, Rebecca G.; Liu, Hong; Zheng, Bin

    2016-03-01

    Although breast MRI is the most sensitive imaging modality to detect early breast cancer, its cancer detection yield in breast cancer screening is quite low (< 3 to 4% even for the small group of high-risk women) to date. The purpose of this preliminary study is to test the potential of developing and applying a new computer-aided detection (CAD) scheme of digital mammograms to identify women at high risk of harboring mammography-occult breast cancers, which can be detected by breast MRI. For this purpose, we retrospectively assembled a dataset involving 30 women who had both mammography and breast MRI screening examinations. All mammograms were interpreted as negative, while 5 cancers were detected using breast MRI. We developed a CAD scheme of mammograms, which include a new quantitative mammographic image feature analysis based risk model, to stratify women into two groups with high and low risk of harboring mammography-occult cancer. Among 30 women, 9 were classified into the high risk group by CAD scheme, which included all 5 women who had cancer detected by breast MRI. All 21 low risk women remained negative on the breast MRI examinations. The cancer detection yield of breast MRI applying to this dataset substantially increased from 16.7% (5/30) to 55.6% (5/9), while eliminating 84% (21/25) unnecessary breast MRI screenings. The study demonstrated the potential of applying a new CAD scheme to significantly increase cancer detection yield of breast MRI, while simultaneously reducing the number of negative MRIs in breast cancer screening.

  4. An information theoretic view of the scheduling problem in whole-body CAD

    NASA Astrophysics Data System (ADS)

    Zhan, Yiqiang; Zhou, Xiang Sean; Krishnan, Arun

    2008-03-01

    Emerging whole-body imaging technologies push computer aided detection/diagnosis (CAD) to scale up to a whole-body level, which involves multiple organs or anatomical structure. To be exploited in this paper is the fact that the various tasks in whole-body CAD are often highly dependent (e.g., the localization of the femur heads strongly predicts the position of the iliac bifurcation of the aorta). One way to effectively employ task dependency is to schedule the tasks such that outputs of some tasks are used to guide the others. In this sense, optimal task scheduling is key to improve overall performance of a whole-body CAD system. In this paper, we propose a method for task scheduling that is optimal in an information-theoretic sense. The central idea is to schedule tasks in such an order that each operation achieves maximum expected information gain over all the tasks. The formulation embeds two intuitive principles: (1) a task with higher confidence tends to be scheduled earlier; (2) a task with higher predictive power for other tasks tends to be scheduled earlier. More specifically, task dependency is modeled by conditional probability; the outcome of each task is assumed to be probabilistic as well; and the objective function is based on the reduction of the summed conditional entropy over all tasks. The validation is carried out on a challenging CAD problem, multi-organ localization in whole-body CT. Compared to unscheduled and ad hoc scheduled organ detection/localization, our scheduled execution achieves higher accuracy with much less computation time.

  5. Teach CAD and Measuring Skills through Reverse Engineering

    ERIC Educational Resources Information Center

    Board, Keith

    2012-01-01

    This article describes a reverse engineering activity that gives students hands-on, minds-on experience with measuring tools, machine parts, and CAD. The author developed this activity to give students an abundance of practical experience with measuring tools. Equally important, it provides a good interface between the virtual world of CAD 3D…

  6. Evaluating the Learning Process of Mechanical CAD Students

    ERIC Educational Resources Information Center

    Hamade, R. F.; Artail, H. A.; Jaber, M. Y.

    2007-01-01

    There is little theoretical or experimental research on how beginner-level trainees learn CAD skills in formal training sessions. This work presents findings on how trainees develop their skills in utilizing a solid mechanical CAD tool (Pro/Engineer version 2000i[squared] and later version Wildfire). Exercises at the beginner and intermediate…

  7. Making a Case for CAD in the Curriculum.

    ERIC Educational Resources Information Center

    Threlfall, K. Denise

    1995-01-01

    Computer-assisted design (CAD) technology is transforming the apparel industry. Students of fashion merchandising and clothing design must be prepared on state-of-the-art equipment. ApparelCAD software is one example of courseware for instruction in pattern design and production. (SK)

  8. A rule based computer aided design system

    NASA Technical Reports Server (NTRS)

    Premack, T.

    1986-01-01

    A Computer Aided Design (CAD) system is presented which supports the iterative process of design, the dimensional continuity between mating parts, and the hierarchical structure of the parts in their assembled configuration. Prolog, an interactive logic programming language, is used to represent and interpret the data base. The solid geometry representing the parts is defined in parameterized form using the swept volume method. The system is demonstrated with a design of a spring piston.

  9. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication.

    PubMed

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now.

  10. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication.

    PubMed

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. PMID:27095912

  11. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication

    PubMed Central

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. PMID:27095912

  12. Radiologists’ Perceptions of Computer Aided Detection versus Double Reading for Mammography Interpretation

    PubMed Central

    Onega, Tracy; Aiello Bowles, Erin J.; Miglioretti, Diana L.; Carney, Patricia A.; Geller, Berta M.; Yankaskas, Bonnie C.; Kerlikowske, Karla; Sickles, Edward A.; Elmore, Joann G.

    2011-01-01

    Rationale and Objectives To examine radiologists’ use and perceptions of computer-aided detection (CAD) and double reading for screening mammography interpretation. Materials and Methods A mailed survey of 257 community radiologists participating in the national Breast Cancer Surveillance Consortium assessed perceptions and practices related to CAD and double reading. We used latent class analysis to classify radiologists’ overall perceptions of CAD and double reading based on their agreement or disagreement with specific statements about CAD and double reading. Results Most radiologists (64%) reported using CAD for more than half the screening mammograms they interpreted, but only <5% reported double reading that much. More radiologists perceived that double reading improved cancer detection rates compared with CAD (74% vs. 55% reported), while fewer radiologists thought that double reading decreased recall rates compared with CAD (50% vs. 65% reported). Radiologists with the most favorable perceptions of CAD were more likely to think that CAD improved cancer detection rate without taking too much time compared with radiologists with the most unfavorable overall perceptions. In latent class analysis an overall favorable perception of CAD was significantly associated with use of CAD (81%), higher percent of workload in screening mammography (80%), academic affiliation (71%), and fellowship training (58%). Perceptions of double reading that were most favorable were associated with academic affiliation (98%). Conclusion Radiologists’ perceptions were more favorable toward double reading by a second clinician than by a computer, although fewer used double reading in their own practice. The majority of radiologists perceived both CAD and double reading at least somewhat favorably, although for largely different reasons. PMID:20832024

  13. Yet another guideline? The UNESCO draft declaration.

    PubMed

    Macklin, Ruth

    2005-09-01

    Some people might argue that there are already too many different documents, guidelines, and regulations in bioethics. Some overlap with one another, some are advisory and lack legal force, others are legally binding in countries, and still others are directed at narrow topics within bioethics, such as HIV/AIDS and human genetics. As the latest document to enter the fray, the UNESCO Declaration has the widest scope of any previous document. It embraces not only research involving human beings, but addresses broader concerns in medicine and healthcare. The UNESCO draft declaration has some minor weaknesses, but on the whole, the strengths outweigh the weaknesses. One weakness is that some items in the draft are stated in a way that is too restrictive, thereby appearing to rule out legitimate activities. A strength of the Declaration is that it is relatively brief, yet at the same time contains sufficient detail to make it something more than a rehearsal of mere pieties. As the most recent of the numerous bioethics and human rights documents, the UNESCO draft draws on many of the earlier documents and also includes some of the most recent thinking about ethical norms and obligations. Perhaps its greatest strength lies not in details of the principles or their implementation, but rather in its stature as an international declaration issued by a United Nations organization. PMID:16128855

  14. Assessment of Chair-side Computer-Aided Design and Computer-Aided Manufacturing Restorations: A Review of the Literature

    PubMed Central

    Baroudi, Kusai; Ibraheem, Shukran Nasser

    2015-01-01

    Background: This paper aimed to evaluate the application of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and the factors that affect the survival of restorations. Materials and Methods: A thorough literature search using PubMed, Medline, Embase, Science Direct, Wiley Online Library and Grey literature were performed from the year 2004 up to June 2014. Only relevant research was considered. Results: The use of chair-side CAD/CAM systems is promising in all dental branches in terms of minimizing time and effort made by dentists, technicians and patients for restoring and maintaining patient oral function and aesthetic, while providing high quality outcome. Conclusion: The way of producing and placing the restorations made with the chair-side CAD/CAM (CEREC and E4D) devices is better than restorations made by conventional laboratory procedures. PMID:25954082

  15. Fracture Rates and Lifetime Estimations of CAD/CAM All-ceramic Restorations.

    PubMed

    Belli, R; Petschelt, A; Hofner, B; Hajtó, J; Scherrer, S S; Lohbauer, U

    2016-01-01

    The gathering of clinical data on fractures of dental restorations through prospective clinical trials is a labor- and time-consuming enterprise. Here, we propose an unconventional approach for collecting large datasets, from which clinical information on indirect restorations can be retrospectively analyzed. The authors accessed the database of an industry-scale machining center in Germany and obtained information on 34,911 computer-aided design (CAD)/computer-aided manufacturing (CAM) all-ceramic posterior restorations. The fractures of bridges, crowns, onlays, and inlays fabricated from different all-ceramic systems over a period of 3.5 y were reported by dentists and entered in the database. Survival analyses and estimations of future life revealed differences in performance among ZrO2-based restorations and lithium disilicate and leucite-reinforced glass-ceramics.

  16. Fracture Rates and Lifetime Estimations of CAD/CAM All-ceramic Restorations.

    PubMed

    Belli, R; Petschelt, A; Hofner, B; Hajtó, J; Scherrer, S S; Lohbauer, U

    2016-01-01

    The gathering of clinical data on fractures of dental restorations through prospective clinical trials is a labor- and time-consuming enterprise. Here, we propose an unconventional approach for collecting large datasets, from which clinical information on indirect restorations can be retrospectively analyzed. The authors accessed the database of an industry-scale machining center in Germany and obtained information on 34,911 computer-aided design (CAD)/computer-aided manufacturing (CAM) all-ceramic posterior restorations. The fractures of bridges, crowns, onlays, and inlays fabricated from different all-ceramic systems over a period of 3.5 y were reported by dentists and entered in the database. Survival analyses and estimations of future life revealed differences in performance among ZrO2-based restorations and lithium disilicate and leucite-reinforced glass-ceramics. PMID:26428908

  17. Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems

    PubMed Central

    Song, Tae-Jin; Kwon, Taek-Ka; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun

    2013-01-01

    PURPOSE Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare the marginal fit of zirconia FPDs made using two CAD/CAM systems with that of metal-ceramic FPDs. MATERIALS AND METHODS Artificial resin maxillary central and lateral incisors were prepared for 3-unit FPDs and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, 15 three-unit FPDs were fabricated per group (45 in total): Group A, zirconia 3-unit FPDs made with the Everest system; Group B, zirconia 3-unit FPDs made with the Lava system; and Group C, metal-ceramic 3-unit FPDs. They were cemented to resin dies with resin cement. After removal of pontic, each retainer was separated and observed under a microscope (Presize 440C). Marginal gaps of experimental groups were analyzed using one-way ANOVA and Duncan test. RESULTS Mean marginal gaps of 3-unit FPDs were 60.46 µm for the Everest group, 78.71 µm for the Lava group, and 81.32 µm for the metal-ceramic group. The Everest group demonstrated significantly smaller marginal gap than the Lava and the metal-ceramic groups (P<.05). The marginal gap did not significantly differ between the Lava and the metal-ceramic groups (P>.05). CONCLUSION The marginal gaps of anterior 3-unit zirconia FPD differed according to CAD/CAM systems, but still fell within clinically acceptable ranges compared with conventional metal-ceramic restoration. PMID:24049561

  18. 77 FR 1491 - Sigma Corporation; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-10

    ... Sigma Corporation; Analysis of Proposed Consent Order To Aid Public Comment AGENCY: Federal Trade.... The attached Analysis to Aid Public Comment describes both the allegations in the draft complaint and... of thirty (30) days. The following Analysis to Aid Public Comment describes the terms of the...

  19. 77 FR 65550 - Compete, Inc.; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-29

    ... Compete, Inc.; Analysis of Proposed Consent Order To Aid Public Comment AGENCY: Federal Trade Commission.... The attached Analysis to Aid Public Comment describes both the allegations in the draft complaint and... Aid Public Comment describes the terms of the consent agreement, and the allegations in the...

  20. 78 FR 55076 - Ganley Ford West, Inc.; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-09

    ... Ganley Ford West, Inc.; Analysis of Proposed Consent Order To Aid Public Comment AGENCY: Federal Trade.... The attached Analysis to Aid Public Comment describes both the allegations in the draft complaint and... placed on the public record for a period of thirty (30) days. The following Analysis to Aid...

  1. 77 FR 2724 - CVS Caremark Corporation; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-19

    ... Caremark Corporation; Analysis of Proposed Consent Order To Aid Public Comment AGENCY: Federal Trade.... The attached Analysis to Aid Public Comment describes both the allegations in the draft complaint and... Aid Public Comment describes the terms of the consent agreement, and the allegations in the...

  2. 75 FR 37806 - Twitter, Inc.; Analysis of Proposed Consent Order to Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-30

    ... Twitter, Inc.; Analysis of Proposed Consent Order to Aid Public Comment AGENCY: Federal Trade Commission.... The attached Analysis to Aid Public Comment describes both the allegations in the draft complaint and... period of thirty (30) days. The following Analysis to Aid Public Comment describes the terms of...

  3. 77 FR 12590 - Winchester Industries; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-01

    ... Winchester Industries; Analysis of Proposed Consent Order To Aid Public Comment AGENCY: Federal Trade.... The attached Analysis to Aid Public Comment describes both the allegations in the draft complaint and... public record for a period of thirty (30) days. The following Analysis to Aid Public Comment...

  4. 77 FR 12584 - Gorell Enterprises, Inc.; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-01

    ... Gorell Enterprises, Inc.; Analysis of Proposed Consent Order To Aid Public Comment AGENCY: Federal Trade.... The attached Analysis to Aid Public Comment describes both the allegations in the ] draft complaint... following Analysis to Aid Public Comment describes the terms of the consent agreement, and the...

  5. AIDS (image)

    MedlinePlus

    AIDS (acquired immune deficiency syndrome) is caused by HIV (human immunodeficiency virus), and is a syndrome that ... life-threatening illnesses. There is no cure for AIDS, but treatment with antiviral medicine can suppress symptoms. ...

  6. Hearing Aids

    MedlinePlus

    ... more in both quiet and noisy situations. Hearing aids help people who have hearing loss from damage ... your doctor. There are different kinds of hearing aids. They differ by size, their placement on or ...

  7. Apex radicis dentis excision operation guided by template made by CAD/CAM

    PubMed Central

    He, Zong-Lai; Cai, Su-Qing; Jin, Guang-Sheng; Liu, Yun-Feng

    2015-01-01

    Objective: The aim of the study is to explore the clinical efficacy of apex radicis dentis excision guided by a template made by Computer Aided Design/Computer Aided Manufacture (CAD/CAM). Methods: Base on the CBCT image of oral cavity, a three-dimensional model of patient’s oral cavity was built. Then the access way and excisional area were defined based on the model. Finally, the operative guide template was designed and made to help define the direction, depth, and area of the surgery. Results: One year after the operation with guide template, the two cases of apex radicis dentis with difficulty in cure were proven to have normal masticatory function and their pathological changes of apex radicis dentis disappeared as well. Conclusion: Utilization of CAD/CAM technology could well design the operative guide template for the resection of apex radicis dentis. Usingthis guide template could make the excision of apex radicis dentis more quickly and safer. PMID:26131072

  8. Luting of CAD/CAM ceramic inlays: direct composite versus dual-cure luting cement.

    PubMed

    Kameyama, Atsushi; Bonroy, Kim; Elsen, Caroline; Lührs, Anne-Katrin; Suyama, Yuji; Peumans, Marleen; Van Meerbeek, Bart; De Munck, Jan

    2015-01-01

    The aim of this study was to investigate bonding effectiveness in direct restorations. A two-step self-etch adhesive and a light-cure resin composite was compared with luting with a conventional dual-cure resin cement and a two-step etch and rinse adhesive. Class-I box-type cavities were prepared. Identical ceramic inlays were designed and fabricated with a computer-aided design/computer-aided manufacturing (CAD/CAM) device. The inlays were seated with Clearfil SE Bond/Clearfil AP-X (Kuraray Medical) or ExciTE F DSC/Variolink II (Ivoclar Vivadent), each by two operators (five teeth per group). The inlays were stored in water for one week at 37°C, whereafter micro-tensile bond strength testing was conducted. The micro-tensile bond strength of the direct composite was significantly higher than that from conventional luting, and was independent of the operator (P<0.0001). Pre-testing failures were only observed with the conventional method. High-power light-curing of a direct composite may be a viable alternative to luting lithium disilicate glass-ceramic CAD/CAM restorations. PMID:26407114

  9. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics.

    PubMed

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-12-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen's size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics.

  10. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics

    PubMed Central

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-01-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen’s size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics. PMID:26816646

  11. An approach to biomimetics: the natural CAD/CAM restoration: a clinical report.

    PubMed

    Schlichting, Luís Henrique; Schlichting, Kathryn Klemz; Stanley, Kyle; Magne, Michel; Magne, Pascal

    2014-02-01

    Those in the dental field have always pursued the perfect dental material for the treatment of compromised teeth. Gold, amalgam, composite resin, glass ionomer, and porcelain have been used. Tooth-like restorative materials (composite resin and porcelain) combined with an effective hard tissue bond have met the growing demand for esthetic or metal-free restorations in the past 15 to 20 years. However, none of those materials can fully mimic the unique properties of dentin (compliance and crack-stopping behavior) and enamel (wear resistance, function). The aim of this article is to report the restoration of an extensively damaged tooth with a natural restoration obtained by milling an extracted third molar tooth with a computer-aided design and computer-aided manufacturing (CAD/CAM) system. The main benefit of this novel technique is the replacement of lost tissues by actual enamel and dentin, with the potential to recover mechanical, esthetic, and biologic properties. The indication for extracting third molars and premolars because of impaction or for orthodontic reasons makes these posterior teeth readily available. The innovation of the method presented here is the optimal use of the extracted tooth substrate thanks to its positioning technique in the CAD/CAM milling chamber.

  12. Automated detection of clustered microcalcifications on mammograms: CAD system application to MIAS database

    NASA Astrophysics Data System (ADS)

    Ibrahim, Norhayati; Fujita, Hiroshi; Hara, Takeshi; Endo, Tokiko

    1997-12-01

    To investigate the detection performance of our automated detection scheme for clustered microcalcifications on mammograms, we applied our computer-aided diagnosis (CAD) system to the database of the Mammographic Image Analysis Society (MIAS) in the UK. Forty-three mammograms from this database were used in this study. In our scheme, the breast regions were firstly extracted by determining the skinline. Histograms of the original images were used to extract the high-density area within the breast region as the segmentation from the fatty area around the skinline. Then the contrast correction technique was employed. Gradient vectors of the image density were calculated on the contrast corrected images. To extract the specific features of the pattern of the microcalcifications, triple-ring filter analysis was employed. A variable-ring filter was used for more accurate detection after the triple-ring filter. The features of the detected candidate areas were then characterized by feature analysis. The areas which satisfied the characteristics and specific terms were classified and displayed as clusters. As a result, the sensitivity was 95.8% with the false-positive rate at 1.8 clusters per image. This demonstrates that the automated detection of clustered microcalcifications in our CAD system is reliable as an aid to radiologists.

  13. Luting of CAD/CAM ceramic inlays: direct composite versus dual-cure luting cement.

    PubMed

    Kameyama, Atsushi; Bonroy, Kim; Elsen, Caroline; Lührs, Anne-Katrin; Suyama, Yuji; Peumans, Marleen; Van Meerbeek, Bart; De Munck, Jan

    2015-01-01

    The aim of this study was to investigate bonding effectiveness in direct restorations. A two-step self-etch adhesive and a light-cure resin composite was compared with luting with a conventional dual-cure resin cement and a two-step etch and rinse adhesive. Class-I box-type cavities were prepared. Identical ceramic inlays were designed and fabricated with a computer-aided design/computer-aided manufacturing (CAD/CAM) device. The inlays were seated with Clearfil SE Bond/Clearfil AP-X (Kuraray Medical) or ExciTE F DSC/Variolink II (Ivoclar Vivadent), each by two operators (five teeth per group). The inlays were stored in water for one week at 37°C, whereafter micro-tensile bond strength testing was conducted. The micro-tensile bond strength of the direct composite was significantly higher than that from conventional luting, and was independent of the operator (P<0.0001). Pre-testing failures were only observed with the conventional method. High-power light-curing of a direct composite may be a viable alternative to luting lithium disilicate glass-ceramic CAD/CAM restorations.

  14. Using CAD software to simulate PV energy yield - The case of product integrated photovoltaic operated under indoor solar irradiation

    SciTech Connect

    Reich, N.H.; van Sark, W.G.J.H.M.; Turkenburg, W.C.; Sinke, W.C.

    2010-08-15

    In this paper, we show that photovoltaic (PV) energy yields can be simulated using standard rendering and ray-tracing features of Computer Aided Design (CAD) software. To this end, three-dimensional (3-D) sceneries are ray-traced in CAD. The PV power output is then modeled by translating irradiance intensity data of rendered images back into numerical data. To ensure accurate results, the solar irradiation data used as input is compared to numerical data obtained from rendered images, showing excellent agreement. As expected, also ray-tracing precision in the CAD software proves to be very high. To demonstrate PV energy yield simulations using this innovative concept, solar radiation time course data of a few days was modeled in 3-D to simulate distributions of irradiance incident on flat, single- and double-bend shapes and a PV powered computer mouse located on a window sill. Comparisons of measured to simulated PV output of the mouse show that also in practice, simulation accuracies can be very high. Theoretically, this concept has great potential, as it can be adapted to suit a wide range of solar energy applications, such as sun-tracking and concentrator systems, Building Integrated PV (BIPV) or Product Integrated PV (PIPV). However, graphical user interfaces of 'CAD-PV' software tools are not yet available. (author)

  15. Hearing Aids

    MedlinePlus

    ... type and degree of loss. Are there different styles of hearing aids? Styles of hearing aids Source: NIH/NIDCD Behind-the- ... the ear canal and are available in two styles. The in-the-canal (ITC) hearing aid is ...

  16. CAD-centric Computation Management System for a Virtual TBM

    SciTech Connect

    Ramakanth Munipalli; K.Y. Szema; P.Y. Huang; C.M. Rowell; A.Ying; M. Abdou

    2011-05-03

    HyPerComp Inc. in research collaboration with TEXCEL has set out to build a Virtual Test Blanket Module (VTBM) computational system to address the need in contemporary fusion research for simulating the integrated behavior of the blanket, divertor and plasma facing components in a fusion environment. Physical phenomena to be considered in a VTBM will include fluid flow, heat transfer, mass transfer, neutronics, structural mechanics and electromagnetics. We seek to integrate well established (third-party) simulation software in various disciplines mentioned above. The integrated modeling process will enable user groups to interoperate using a common modeling platform at various stages of the analysis. Since CAD is at the core of the simulation (as opposed to computational meshes which are different for each problem,) VTBM will have a well developed CAD interface, governing CAD model editing, cleanup, parameter extraction, model deformation (based on simulation,) CAD-based data interpolation. In Phase-I, we built the CAD-hub of the proposed VTBM and demonstrated its use in modeling a liquid breeder blanket module with coupled MHD and structural mechanics using HIMAG and ANSYS. A complete graphical user interface of the VTBM was created, which will form the foundation of any future development. Conservative data interpolation via CAD (as opposed to mesh-based transfer), the regeneration of CAD models based upon computed deflections, are among the other highlights of phase-I activity.

  17. Investigation of IGES for CAD/CAE data transfer

    NASA Technical Reports Server (NTRS)

    Zobrist, George W.

    1989-01-01

    In a CAD/CAE facility there is always the possibility that one may want to transfer the design graphics database from the native system to a non-native system. This may occur because of dissimilar systems within an organization or a new CAD/CAE system is to be purchased. The Initial Graphics Exchange Specification (IGES) was developed in an attempt to solve this scenario. IGES is a neutral database format into which the CAD/CAE native database format can be translated to and from. Translating the native design database format to IGES requires a pre-processor and transling from IGES to the native database format requires a post-processor. IGES is an artifice to represent CAD/CAE product data in a neutral environment to allow interfacing applications, archive the database, interchange of product data between dissimilar CAD/CAE systems, and other applications. The intent here is to present test data on translating design product data from a CAD/CAE system to itself and to translate data initially prepared in IGES format to various native design formats. This information can be utilized in planning potential procurement and developing a design discipline within the CAD/CAE community.

  18. Drafting Lab Management Guide.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Instructional Materials Lab.

    This manual was developed to guide drafting instructors and vocational supervisors in sequencing laboratory instruction and controlling the flow of work for a 2-year machine trades training program. The first part of the guide provides information on program management (program description, safety concerns, academic issues, implementation…

  19. Drafting. Competency Based Curriculum.

    ERIC Educational Resources Information Center

    Everly, Al; And Others

    This competency based drafting curriculum is presented in seven specialization sections with units in each section containing a competency statement, performance objective, learning activities, evaluation, and quiz or problem sheets. Some units also contain answer sheets and/or handout sheets. Sections and number of units presented are (1) basic…

  20. Caught in the Draft

    ERIC Educational Resources Information Center

    Edge, Ron

    2007-01-01

    We've all seen (in movies, newscasts, or perhaps in person) the violent effect of the downwash that occurs when a helicopter hovers over the ground. Leaves, grass, and debris are dramatically blown about. We've also sat in front of circulating room fans and felt a large draft, whereas there seems to be very little air movement behind the fan. The…

  1. Drafting the Basics

    ERIC Educational Resources Information Center

    Lamb, Carol M.; Kurtanich, David G.

    2007-01-01

    This paper outlines the work in progress undertaken by the School of Engineering Technology faculty to identify, assess, and develop a course to address the depth and breadth of drafting/plan preparation and plan reading skills required by the various engineering technology programs offered at Youngstown State University. The methodology used to…

  2. Effect of the Crystallization Process on the Marginal and Internal Gaps of Lithium Disilicate CAD/CAM Crowns

    PubMed Central

    Kim, Jae-Hong; Oh, Seunghan; Uhm, Soo-Hyuk

    2016-01-01

    The aim of this study is to quantify the effect of the crystallization process on lithium disilicate ceramic crowns fabricated using a computer-aided design/computer-aided manufacturing (CAD/CAM) system and to determine whether the effect of crystallization is clinically acceptable by comparing values of fit before and after the crystallization process. The mandibular right first molar was selected as the abutment for the experiments. Fifteen working models were prepared. Lithium disilicate crowns appropriate for each abutment were prepared using a commercial CAD/CAM system. Gaps in the marginal area and 4 internal areas of each crown were measured twice—before and after crystallization—using the silicone replica technique. The mean values of fit before and after crystallization were analyzed using a paired t-test to examine whether the conversion that occurred during crystallization affected marginal and internal gaps (α = 0.05). Gaps increased in the marginal area and decreased in the internal areas after crystallization. There were statistically significant differences in all of the investigated areas (P < 0.05). None of the values for marginal and internal fit of lithium disilicate CAD/CAM crowns after crystallization exceeded 120 μm, which is the clinically acceptable threshold. PMID:27123453

  3. Effect of the Crystallization Process on the Marginal and Internal Gaps of Lithium Disilicate CAD/CAM Crowns.

    PubMed

    Kim, Jae-Hong; Oh, Seunghan; Uhm, Soo-Hyuk

    2016-01-01

    The aim of this study is to quantify the effect of the crystallization process on lithium disilicate ceramic crowns fabricated using a computer-aided design/computer-aided manufacturing (CAD/CAM) system and to determine whether the effect of crystallization is clinically acceptable by comparing values of fit before and after the crystallization process. The mandibular right first molar was selected as the abutment for the experiments. Fifteen working models were prepared. Lithium disilicate crowns appropriate for each abutment were prepared using a commercial CAD/CAM system. Gaps in the marginal area and 4 internal areas of each crown were measured twice-before and after crystallization-using the silicone replica technique. The mean values of fit before and after crystallization were analyzed using a paired t-test to examine whether the conversion that occurred during crystallization affected marginal and internal gaps (α = 0.05). Gaps increased in the marginal area and decreased in the internal areas after crystallization. There were statistically significant differences in all of the investigated areas (P < 0.05). None of the values for marginal and internal fit of lithium disilicate CAD/CAM crowns after crystallization exceeded 120 μm, which is the clinically acceptable threshold. PMID:27123453

  4. A survey on computer aided diagnosis for ocular diseases

    PubMed Central

    2014-01-01

    Background Computer Aided Diagnosis (CAD), which can automate the detection process for ocular diseases, has attracted extensive attention from clinicians and researchers alike. It not only alleviates the burden on the clinicians by providing objective opinion with valuable insights, but also offers early detection and easy access for patients. Method We review ocular CAD methodologies for various data types. For each data type, we investigate the databases and the algorithms to detect different ocular diseases. Their advantages and shortcomings are analyzed and discussed. Result We have studied three types of data (i.e., clinical, genetic and imaging) that have been commonly used in existing methods for CAD. The recent developments in methods used in CAD of ocular diseases (such as Diabetic Retinopathy, Glaucoma, Age-related Macular Degeneration and Pathological Myopia) are investigated and summarized comprehensively. Conclusion While CAD for ocular diseases has shown considerable progress over the past years, the clinical importance of fully automatic CAD systems which are able to embed clinical knowledge and integrate heterogeneous data sources still show great potential for future breakthrough. PMID:25175552

  5. Computer-aided design for metabolic engineering.

    PubMed

    Fernández-Castané, Alfred; Fehér, Tamás; Carbonell, Pablo; Pauthenier, Cyrille; Faulon, Jean-Loup

    2014-12-20

    The development and application of biotechnology-based strategies has had a great socio-economical impact and is likely to play a crucial role in the foundation of more sustainable and efficient industrial processes. Within biotechnology, metabolic engineering aims at the directed improvement of cellular properties, often with the goal of synthesizing a target chemical compound. The use of computer-aided design (CAD) tools, along with the continuously emerging advanced genetic engineering techniques have allowed metabolic engineering to broaden and streamline the process of heterologous compound-production. In this work, we review the CAD tools available for metabolic engineering with an emphasis, on retrosynthesis methodologies. Recent advances in genetic engineering strategies for pathway implementation and optimization are also reviewed as well as a range of bionalytical tools to validate in silico predictions. A case study applying retrosynthesis is presented as an experimental verification of the output from Retropath, the first complete automated computational pipeline applicable to metabolic engineering. Applying this CAD pipeline, together with genetic reassembly and optimization of culture conditions led to improved production of the plant flavonoid pinocembrin. Coupling CAD tools with advanced genetic engineering strategies and bioprocess optimization is crucial for enhanced product yields and will be of great value for the development of non-natural products through sustainable biotechnological processes.

  6. Computer-aided design for metabolic engineering.

    PubMed

    Fernández-Castané, Alfred; Fehér, Tamás; Carbonell, Pablo; Pauthenier, Cyrille; Faulon, Jean-Loup

    2014-12-20

    The development and application of biotechnology-based strategies has had a great socio-economical impact and is likely to play a crucial role in the foundation of more sustainable and efficient industrial processes. Within biotechnology, metabolic engineering aims at the directed improvement of cellular properties, often with the goal of synthesizing a target chemical compound. The use of computer-aided design (CAD) tools, along with the continuously emerging advanced genetic engineering techniques have allowed metabolic engineering to broaden and streamline the process of heterologous compound-production. In this work, we review the CAD tools available for metabolic engineering with an emphasis, on retrosynthesis methodologies. Recent advances in genetic engineering strategies for pathway implementation and optimization are also reviewed as well as a range of bionalytical tools to validate in silico predictions. A case study applying retrosynthesis is presented as an experimental verification of the output from Retropath, the first complete automated computational pipeline applicable to metabolic engineering. Applying this CAD pipeline, together with genetic reassembly and optimization of culture conditions led to improved production of the plant flavonoid pinocembrin. Coupling CAD tools with advanced genetic engineering strategies and bioprocess optimization is crucial for enhanced product yields and will be of great value for the development of non-natural products through sustainable biotechnological processes. PMID:24704607

  7. Fabrication of a CAD/CAM monolithic zirconia crown to fit an existing partial removable dental prosthesis

    PubMed Central

    2016-01-01

    Fabricating a surveyed prosthesis beneath an existing partial removable dental prosthesis (PRDP) is a challenging and time-consuming procedure. The computer-aided design/computer-assisted manufacturing (CAD/CAM) technology was applied to fabricate a retrofitted, surveyed zirconia prosthesis to an existing PRDP. CAD/CAM technology enabled precise and easy replication of the contour of the planned surveyed crown on the existing abutment tooth. This technology ensured excellent adaptation and fit of newly fabricated crown to the existing PRDP with minimal adjustments. In this case report, a seventy-year-old male patient presented with fractured existing surveyed crown. Because the existing PRDP was serviceable, new crown was fabricated to the existing PRDP. PMID:27555903

  8. Fabrication of a CAD/CAM monolithic zirconia crown to fit an existing partial removable dental prosthesis.

    PubMed

    Paek, Janghyun; Noh, Kwantae; Pae, Ahran; Lee, Hyeonjong; Kim, Hyeong-Seob

    2016-08-01

    Fabricating a surveyed prosthesis beneath an existing partial removable dental prosthesis (PRDP) is a challenging and time-consuming procedure. The computer-aided design/computer-assisted manufacturing (CAD/CAM) technology was applied to fabricate a retrofitted, surveyed zirconia prosthesis to an existing PRDP. CAD/CAM technology enabled precise and easy replication of the contour of the planned surveyed crown on the existing abutment tooth. This technology ensured excellent adaptation and fit of newly fabricated crown to the existing PRDP with minimal adjustments. In this case report, a seventy-year-old male patient presented with fractured existing surveyed crown. Because the existing PRDP was serviceable, new crown was fabricated to the existing PRDP. PMID:27555903

  9. A public image database to support research in computer aided diagnosis.

    PubMed

    Reeves, A P; Biancardi, A M; Yankelevitz, D; Fotin, S; Keller, B M; Jirapatnakul, A; Lee, J

    2009-01-01

    The Public Lung Database to address drug response (PLD) has been developed to support research in computer aided diagnosis (CAD). Originally established for applications involving the characterization of pulmonary nodules, the PLD has been augmented to provide initial datasets for CAD research of other diseases. In general, the best performance for a CAD system is achieved when it is trained with a large amount of well documented data. Such training databases are very expensive to create and their lack of general availability limits the targets that can be considered for CAD applications and hampers development of the CAD field. The approach taken with the PLD has been to make available small datasets together with both manual and automated documentation. Furthermore, datasets with special properties are provided either to span the range of task complexity or to provide small change repeat images for direct calibration and evaluation of CAD systems. This resource offers a starting point for other research groups wishing to pursue CAD research in new directions. It also provides an on-line reference for better defining the issues relating to specific CAD tasks.

  10. 46 CFR 131.220 - Drafts.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Drafts. (a) Each vessel must have the drafts of the vessel plainly and legibly marked upon the stem and... stem or cutaway skeg, the keel does not extend forward or aft to the draft markings, the datum...

  11. Voice I/O: an effective option for CAD systems

    SciTech Connect

    Gill, S.P.

    1983-01-01

    The current state of speech recognition and compression technology is examined. The application of this technology to input/output in the CAD environment is then considered. Human factors are discussed.

  12. CAD/CAM approach to improving industry productivity gathers momentum

    NASA Technical Reports Server (NTRS)

    Fulton, R. E.

    1982-01-01

    Recent results and planning for the NASA/industry Integrated Programs for Aerospace-Vehicle Design (IPAD) program for improving productivity with CAD/CAM methods are outlined. The industrial group work is being mainly done by Boeing, and progress has been made in defining the designer work environment, developing requirements and a preliminary design for a future CAD/CAM system, and developing CAD/CAM technology. The work environment was defined by conducting a detailed study of a reference design process, and key software elements for a CAD/CAM system have been defined, specifically for interactive design or experiment control processes. Further work is proceeding on executive, data management, geometry and graphics, and general utility software, and dynamic aspects of the programs being developed are outlined

  13. [Development of the dental CAD/CAM system].

    PubMed

    Kawanaka, M

    1990-06-01

    Studies have been undertaken to apply CAD/CAM system to Dentistry and to make prosthetic appliances with this system automatically. Specimens are 4 times large plaster models. For the inside of the crown, the plaster model of prepared tooth is measured with laser displacement meter then the numerical data is obtained. After modification of this data for the concave cutting, the modeling machine works with this numerical data. For the outside of the crown, the typical colonal figure data (= CAD Data Base) is prepared. And this data is modified with computer to fit the prepared tooth margin and proximal or antagonical tooth (= CAD). This CAD Data Base was obtained with 3 dimensional point digitizer (3DPD). Because this measuring method with 3DPD is to be able to select points, the CAD Data Base could be consists of characteristic points. When this data base is really used, it is interpolated with s-spline. Spline interpolation is indispensable to the CAD/CAM system. Further understanding of this system, explanation is divided into three parts which are 3D measurement, CAD and CAM. (3D measurement) Two types of 3D measurement is dealed with this system. One is for the CAD data base and another is for the prepared tooth model. 3D measurement of the prepared tooth model is equivalent of the impression takings in the routine method. For the clear marginal line and for the uniform distribution of measuring points, the prepared tooth model is tilted and rotated on the working table when it is measured with laser. (CAD) The CAD Data Base can be extended, contracted, parallel translated and rotated with the Affine transformation. For putting the individual margin data on the CAD Data Base, the prepared tooth margin is re-digitized with 3DPD. Occlusal data is taken from F.G.P. core. (CAM) The application of the spline interpolation to the tool offset theory, which is effective at the groove especially, makes easy to calculate the tool path. When the prepared tooth model is

  14. A completely automated CAD system for mass detection in a large mammographic database

    SciTech Connect

    Bellotti, R.; De Carlo, F.; Tangaro, S.

    2006-08-15

    Mass localization plays a crucial role in computer-aided detection (CAD) systems for the classification of suspicious regions in mammograms. In this article we present a completely automated classification system for the detection of masses in digitized mammographic images. The tool system we discuss consists in three processing levels: (a) Image segmentation for the localization of regions of interest (ROIs). This step relies on an iterative dynamical threshold algorithm able to select iso-intensity closed contours around gray level maxima of the mammogram. (b) ROI characterization by means of textural features computed from the gray tone spatial dependence matrix (GTSDM), containing second-order spatial statistics information on the pixel gray level intensity. As the images under study were recorded in different centers and with different machine settings, eight GTSDM features were selected so as to be invariant under monotonic transformation. In this way, the images do not need to be normalized, as the adopted features depend on the texture only, rather than on the gray tone levels, too. (c) ROI classification by means of a neural network, with supervision provided by the radiologist's diagnosis. The CAD system was evaluated on a large database of 3369 mammographic images [2307 negative, 1062 pathological (or positive), containing at least one confirmed mass, as diagnosed by an expert radiologist]. To assess the performance of the system, receiver operating characteristic (ROC) and free-response ROC analysis were employed. The area under the ROC curve was found to be A{sub z}=0.783{+-}0.008 for the ROI-based classification. When evaluating the accuracy of the CAD against the radiologist-drawn boundaries, 4.23 false positives per image are found at 80% of mass sensitivity.

  15. The application of computer-aided technologies in automotive styling design

    NASA Astrophysics Data System (ADS)

    Zheng, Ze-feng; Zhang, Ji; Zheng, Ying

    2012-04-01

    In automotive industry, outline design is its life and creative design is its soul indeed. Computer-aided technology has been widely used in the automotive industry and more and more attention has been paid. This paper chiefly introduce the application of computer-aided technologies including CAD, CAM and CAE, analyses the process of automotive structural design and describe the development tendency of computer-aided design.

  16. Financial Aid.

    ERIC Educational Resources Information Center

    Graves, Mary A.

    This workbook assists college and vocational school bound American Indian students in determining their financial needs and in locating sources of financial aid. A checklist helps students assess the state of their knowledge of financial programs; a glossary defines terms pertinent to the realm of financial aid (i.e., graduate study programs,…

  17. Teaching AIDS.

    ERIC Educational Resources Information Center

    Tonks, Douglas

    This book presents a curriculum to educate students about the risk of AIDS and HIV infection. The opening chapters of the book presents a discussion of: how teachers can create an environment of support for an AIDS education program; the political and educational implications of winning principal, district, and parental support for an AIDS…

  18. Computer-aided detection in full-field digital mammography in a clinical population: performance of radiologist and technologists.

    PubMed

    van den Biggelaar, Frank J H M; Kessels, Alphons G H; van Engelshoven, Jos M A; Boetes, Carla; Flobbe, Karin

    2010-04-01

    The purpose of the study was to evaluate the impact of a computer-aided detection (CAD) system on the performance of mammogram readers in interpreting digital mammograms in a clinical population. Furthermore, the ability of a CAD system to detect breast cancer in digital mammography was studied in comparison to the performance of radiologists and technologists as mammogram readers. Digital mammograms of 1,048 consecutive patients were evaluated by a radiologist and three technologists. Abnormalities were recorded and an imaging conclusion was given as a BI-RADS score before and after CAD analysis. Pathology results during 12 months follow up were used as a reference standard for breast cancer. Fifty-one malignancies were found in 50 patients. Sensitivity and specificity were computed before and after CAD analysis and provided with 95% CIs. In order to assess the detection rate of malignancies by CAD and the observers, the pathological locations of these 51 breast cancers were matched with the locations of the CAD marks and the mammographic locations that were considered to be suspicious by the observers. For all observers, the sensitivity rates did not change after application of CAD. A mean sensitivity of 92% was found for all technologists and 84% for the radiologist. For two technologists, the specificity decreased (from 84 to 83% and from 77 to 75%). For the radiologist and one technologist, the application of CAD did not have any impact on the specificity rates (95 and 83%, respectively). CAD detected 78% of all malignancies. Five malignancies were indicated by CAD without being noticed as suspicious by the observers. In conclusion, the results show that systematic application of CAD in a clinical patient population failed to improve the overall sensitivity of mammogram interpretation by the readers and was associated with an increase in false-positive results. However, CAD marked five malignancies that were missed by the different readers. PMID:19418215

  19. Electrical and Electronic Drafting, Drafting 3: 9257.01.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    The course covers the standards used in the electronic field, electrical drawings, electronic drafting, and parts of functional drafting. The student will become familiar with symbols used in these fields and become proficient with tools and reference material used in drawing schematics and mechanical details and in electrical and electronic…

  20. Drafting--Basic, Drafting--Intermediate: 9255.01.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    The course has no prerequisites, offers instruction in basic drafting room techniques and procedures, and also covers job opportunities and industrial methods in engineering. The student is introduced to and asked to perform fundamental drafting problems with working drawings, using multiview and auxiliary views and sections. The course also…

  1. Mammographic computer-aided detection systems.

    PubMed

    2003-04-01

    While mammography is regarded as the best means available to screen for breast cancer, reading mammograms is a tedious, error-prone task. Given the repetitiveness of the process and the fact that less than 1% of mammograms in the average screening population contain cancer, it's no wonder that a significant number of breast cancers--about 28%--are missed by radiologists. The fact that human error is such a significant obstacle makes mammography screening an ideal application for computer-aided detection (CAD) systems. CAD systems serve as a "second pair of eyes" to ensure that radiologists don't miss a suspect area on an image. They analyze patterns on a digitized mammographic image, identify regions that may contain an abnormality indicating cancer, and mark these regions. The marks are then inspected and classified by a radiologist. But CAD systems provide no diagnosis of any kind--it's up to the radiologist to analyze the marked area and decide if it shows cancer. In this Evaluation, we describe the challenges posed by screening mammography, the operating principles and overall efficacy of CAD systems, and the characteristics to consider when purchasing a system. We also compare the performance of two commercially available systems, iCAD's MammoReader and R2's ImageChecker. Because the two systems offer comparable sensitivity, our judgments are based on other performance characteristics, including their ease of use, the number of false marks they produce, the degree to which they can integrate with hospital information systems, and their processing speed.

  2. The MAGIC-5 CAD for nodule detection in low dose and thin slice lung CTs

    NASA Astrophysics Data System (ADS)

    Cerello, Piergiorgio; MAGIC-5 Collaboration

    2010-11-01

    Lung cancer is the leading cause of cancer-related mortality in developed countries. Only 10-15% of all men and women diagnosed with lung cancer live 5 years after the diagnosis. However, the 5-year survival rate for patients diagnosed in the early asymptomatic stage of the disease can reach 70%. Early-stage lung cancers can be diagnosed by detecting non-calcified small pulmonary nodules with computed tomography (CT). Computer-aided detection (CAD) could support radiologists in the analysis of the large amount of noisy images generated in screening programs, where low-dose and thin-slice settings are used. The MAGIC-5 project, funded by the Istituto Nazionale di Fisica Nucleare (INFN, Italy) and Ministero dell'Università e della Ricerca (MUR, Italy), developed a multi-method approach based on three CAD algorithms to be used in parallel with a merging of their results: the Channeler Ant Model (CAM), based on Virtual Ant Colonies, the Dot-Enhancement/Pleura Surface Normals/VBNA (DE-PSN-VBNA), and the Region Growing Volume Plateau (RGVP). Preliminary results show quite good performances, to be improved with the refining of the single algorithm and the added value of the results merging.

  3. Preliminary investigation on CAD system update: effect of selection of new cases on classifier performance

    NASA Astrophysics Data System (ADS)

    Muramatsu, Chisako; Nishimura, Kohei; Hara, Takeshi; Fujita, Hiroshi

    2013-02-01

    When a computer-aided diagnosis (CAD) system is used in clinical practice, it is desirable that the system is constantly and automatically updated with new cases obtained for performance improvement. In this study, the effect of different case selection methods for the system updates was investigated. For the simulation, the data for classification of benign and malignant masses on mammograms were used. Six image features were used for training three classifiers: linear discriminant analysis (LDA), support vector machine (SVM), and k-nearest neighbors (kNN). Three datasets, including dataset I for initial training of the classifiers, dataset T for intermediate testing and retraining, and dataset E for evaluating the classifiers, were randomly sampled from the database. As a result of intermediate testing, some cases from dataset T were selected to be added to the previous training set in the classifier updates. In each update, cases were selected using 4 methods: selection of (a) correctly classified samples, (b) incorrectly classified samples, (c) marginally classified samples, and (d) random samples. For comparison, system updates using all samples in dataset T were also evaluated. In general, the average areas under the receiver operating characteristic curves (AUCs) were almost unchanged with method (a), whereas AUCs generally degraded with method (b). The AUCs were improved with method (c) and (d), although use of all available cases generally provided the best or nearly best AUCs. In conclusion, CAD systems may be improved by retraining with new cases accumulated during practice.

  4. Trial of duplication procedure for complete dentures by CAD/CAM.

    PubMed

    Kawahata, N; Ono, H; Nishi, Y; Hamano, T; Nagaoka, E

    1997-07-01

    The purpose of this study was to duplicate the shapes of complete dentures by using a computer-aided design/manufacturing (CAD/CAM) system. The shapes of the complete dentures of an edentulous patient were measured using a non-contact type shape measurement system and morphological data at the interval of 0.25 mm were obtained in the X-axis and Y-axis directions. Measurement was performed from the occlusal surface and mucosal surface sides. Based on the three-dimensional morphological data, cutter paths for cutting were generated. For cutting, the three-step method consisting of rough cutting, finish cutting, and partial finish cutting was used and for duplicating the dentures the modelling wax was cut using a computerized numerical control (CNC) processor and ball-end mills with diameters of 6 mm and 1 mm. The method for the controlling of three axes (X, Y, and Z) of CNC machine was used, and cutting was performed only from two directions. Although further improvements are needed in the measurement and cutting in acute slope areas, the duplication of complete dentures appears to be possible using the CAD/CAM system. PMID:9250843

  5. Computer-aided diagnosis in lung nodule assessment.

    PubMed

    Goldin, Jonathan G; Brown, Matthew S; Petkovska, Iva

    2008-05-01

    Computed tomography (CT) imaging is playing an increasingly important role in cancer detection, diagnosis, and lesion characterization, and it is the most sensitive test for lung nodule detection. Interpretation of lung nodules involves characterization and integration of clinical and other imaging information. Advances in lung nodule management using CT require optimization of CT data acquisition, postprocessing tools, and computer-aided diagnosis (CAD). The goal of CAD systems being developed is to both assist radiologists in the more sensitive detection of nodules and noninvasively differentiate benign from malignant lesions; the latter is important given that malignant lesions account for between 1% and 11% of pulmonary nodules. The aim of this review is to summarize the current state of the art regarding CAD techniques for the detection and characterization of solitary pulmonary nodules and their potential applications in the clinical workup of these lesions.

  6. Industrial Education. Drafting. [Grade 9].

    ERIC Educational Resources Information Center

    Parma City School District, OH.

    Part of a series of curriculum guides dealing with industrial education in junior high schools, this guide provides a course on drafting to be used in the ninth grade. Thirteen goals are identified for the students to demonstrate: (1) a knowledge of the relationship between drafting and the work of designers, engineers, and architects; (2) an…

  7. Synthesis of the Growth Hormone Secretion Mechanism Using Nonlinear Analysis and CAD Tools.

    PubMed

    Shell, J R

    2005-01-01

    The goal of this paper is to present a hardware realization of the feed-forward and feedback hypothalamic-pituitary growth hormone (GH) secretion mechanism based on a bio-mathematical nonlinear delay differential equation model developed by Farhy et al. (2003) and Veldhuis et al. (2001). Behavioral modeling is implemented through Verilog hardware descriptive language (HDL) to simulate the antagonistic and stimulatory interaction of growth hormone, growth hormone releasing hormone (GHRH) and somatotropin release inhibiting factor (SRIF). The model is synthesized using computer aided design (CAD) tools and is promulgated through a combinational complex programmable logic device (CPLD)/field programmable grid array (FPGA) Xilinx XSA-50 microchip. The microchip sequentially displays the decimal equivalents of the time changing hormonal concentration levels of the biomathematical model.

  8. An Integrated Unix-based CAD System for the Design and Testing of Custom VLSI Chips

    NASA Technical Reports Server (NTRS)

    Deutsch, L. J.

    1985-01-01

    A computer aided design (CAD) system that is being used at the Jet Propulsion Laboratory for the design of custom and semicustom very large scale integrated (VLSI) chips is described. The system consists of a Digital Equipment Corporation VAX computer with the UNIX operating system and a collection of software tools for the layout, simulation, and verification of microcircuits. Most of these tools were written by the academic community and are, therefore, available to JPL at little or no cost. Some small pieces of software have been written in-house in order to make all the tools interact with each other with a minimal amount of effort on the part of the designer.

  9. 1st Order Modeling of a SAW Delay Line using MathCAD(Registered)

    NASA Technical Reports Server (NTRS)

    Wilson, William C.; Atkinson, Gary M.

    2007-01-01

    To aid in the development of SAW sensors for Integrated Vehicle Health Monitoring applications, a first order model of a SAW Delay line has been created using MathCadA. The model implements the Impulse Response method to calculate the frequency response, impedance, and insertion loss. This paper presents the model and the results from the model for a SAW delay line design. Integrated Vehicle Health Monitoring (IVHM) of aerospace vehicles requires rugged sensors having reduced volume, mass, and power that can be used to measure a variety of phenomena. Wireless systems are preferred when retro-fitting sensors onto existing vehicles [1]. Surface Acoustic Wave (SAW) devices are capable of sensing: temperature, pressure, strain, chemical species, mass loading, acceleration, and shear stress. SAW technology is low cost, rugged, lightweight, and extremely low power. Passive wireless sensors have been developed using SAW technology. For these reasons new SAW sensors are being investigated for aerospace applications.

  10. Performance and value of CAD-deficient pine- Final Report

    SciTech Connect

    Bailian Li; Houmin Chang; Hasan Jameel

    2007-02-28

    The southern US produces 58% of the nation's timber, much of it grown in intensively managed plantations of genetically improved loblolly pine. One of the fastest-growing loblolly pine selections made by the NCSU-Industry Cooperative Tree Improvement Program, whose progeny are widely planted, is also the only known natural carrier of a rare gene, cadn1. This allele codes for deficiency in an enzyme, cinnamyl alcohol dehydrogenase, which catalyzes the last step in the biosynthesis of lignin precursors. This study is to characterize this candidate gene for marker-assisted selection and deployment in the breeding program. This research will enhance the sustainability of forest production in the South, where land-use pressures will limit the total area available in the future for intensively managed plantations. Furthermore, this research will provide information to establish higher-value plantation forests with more desirable wood/fiber quality traits. A rare mutant allele (cad-n1) of the cad gene in loblolly pine (Pinus taeda L.) causes a deficiency in the production of cinnamyl alcohol dehydrogenase (CAD). The effects of this allele were examined by comparing wood density and growth traits of cad-n1 heterozygous trees with those of wild-type trees in a 10-year-old open-pollinated family trial growing under two levels of fertilization in Scotland County, North Carolina. In all, 200 trees were sampled with 100 trees for each treatment. Wood density measurements were collected from wood cores at breast height using x-ray densitometry. We found that the substitution of cad-n1 for a wild-type allele (Cad) was associated with a significant effect on wood density. The cad-n1 heterozygotes had a significantly higher wood density (+2.6%) compared to wild-type trees. The higher density was apparently due to the higher percentage of latewood in the heterozygotes. The fertilization effect was highly significant for both growth and wood density traits. While no cad genotype x

  11. Concerns of Hydrothermal Degradation in CAD/CAM Zirconia

    PubMed Central

    Kim, J.-W.; Covel, N.S.; Guess, P.C.; Rekow, E.D.; Zhang, Y.

    2010-01-01

    Zirconia-based restorations are widely used in prosthetic dentistry; however, their susceptibility to hydrothermal degradation remains elusive. We hypothesized that CAD/CAM machining and subsequent surface treatments, i.e., grinding and/or grit-blasting, have marked effects on the hydrothermal degradation behavior of Y-TZP. CAD/CAM-machined Y-TZP plates (0.5 mm thick), both with and without subsequent grinding with various grit sizes or grit-blasting with airborne alumina particles, were subjected to accelerated aging tests in a steam autoclave. Results showed that the CAD/CAM-machined surfaces initially exhibited superior hydrothermal degradation resistance, but deteriorated at a faster rate upon prolonged autoclave treatment compared with ground and grit-blasted surfaces. The accelerated hydrothermal degradation of CAD/CAM surfaces is attributed to the CAD/CAM machining damage and the absence of surface compressive stresses in the fully sintered material. Clinical relevance for surface treatments of zirconia frameworks in terms of hydrothermal and structural stabilities is addressed. PMID:19966039

  12. Concerns of hydrothermal degradation in CAD/CAM zirconia.

    PubMed

    Kim, J-W; Covel, N S; Guess, P C; Rekow, E D; Zhang, Y

    2010-01-01

    Zirconia-based restorations are widely used in prosthetic dentistry; however, their susceptibility to hydrothermal degradation remains elusive. We hypothesized that CAD/CAM machining and subsequent surface treatments, i.e., grinding and/or grit-blasting, have marked effects on the hydrothermal degradation behavior of Y-TZP. CAD/CAM-machined Y-TZP plates (0.5 mm thick), both with and without subsequent grinding with various grit sizes or grit-blasting with airborne alumina particles, were subjected to accelerated aging tests in a steam autoclave. Results showed that the CAD/CAM-machined surfaces initially exhibited superior hydrothermal degradation resistance, but deteriorated at a faster rate upon prolonged autoclave treatment compared with ground and grit-blasted surfaces. The accelerated hydrothermal degradation of CAD/CAM surfaces is attributed to the CAD/CAM machining damage and the absence of surface compressive stresses in the fully sintered material. Clinical relevance for surface treatments of zirconia frameworks in terms of hydrothermal and structural stabilities is addressed.

  13. Clinical Criteria for Physician Aid in Dying.

    PubMed

    Orentlicher, David; Pope, Thaddeus Mason; Rich, Ben A

    2016-03-01

    More than 20 years ago, even before voters in Oregon had enacted the first aid in dying (AID) statute in the United States, Timothy Quill and colleagues proposed clinical criteria AID. Their proposal was carefully considered and temperate, but there were little data on the practice of AID at the time. (With AID, a physician writes a prescription for life-ending medication for a terminally ill, mentally capacitated adult.) With the passage of time, a substantial body of data on AID has developed from the states of Oregon and Washington. For more than 17 years, physicians in Oregon have been authorized to provide a prescription for AID. Accordingly, we have updated the clinical criteria of Quill, et al., based on the many years of experience with AID. With more jurisdictions authorizing AID, it is critical that physicians can turn to reliable clinical criteria. As with any medical practice, AID must be provided in a safe and effective manner. Physicians need to know (1) how to respond to a patient's inquiry about AID, (2) how to assess patient decision making capacity, and (3) how to address a range of other issues that may arise. To ensure that physicians have the guidance they need, Compassion & Choices convened the Physician Aid-in-Dying Clinical Criteria Committee, in July 2012, to create clinical criteria for physicians who are willing to provide AID to patients who request it. The committee includes experts in medicine, law, bioethics, hospice, nursing, social work, and pharmacy. Using an iterative consensus process, the Committee drafted the criteria over a one-year period.

  14. Hearing Aid

    MedlinePlus

    ... and Food and Drug Administration Staff FDA permits marketing of new laser-based hearing aid with potential ... feeds Follow FDA on Twitter Follow FDA on Facebook View FDA videos on YouTube View FDA photos ...

  15. 32 CFR 989.19 - Draft EIS.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... review of draft EIS (40 CFR 1502.19 and 1506.6): (1) The public comment period for the draft EIS is at... summary to the public with an attached list of locations (such as public libraries) where the entire draft... proponent in preparation of a preliminary draft EIS (PDEIS) (40 CFR 1502.9) based on the scope of...

  16. The evaluation of multi-structure, multi-atlas pelvic anatomy features in a prostate MR lymphography CAD system

    NASA Astrophysics Data System (ADS)

    Meijs, M.; Debats, O.; Huisman, H.

    2015-03-01

    In prostate cancer, the detection of metastatic lymph nodes indicates progression from localized disease to metastasized cancer. The detection of positive lymph nodes is, however, a complex and time consuming task for experienced radiologists. Assistance of a two-stage Computer-Aided Detection (CAD) system in MR Lymphography (MRL) is not yet feasible due to the large number of false positives in the first stage of the system. By introducing a multi-structure, multi-atlas segmentation, using an affine transformation followed by a B-spline transformation for registration, the organ location is given by a mean density probability map. The atlas segmentation is semi-automatically drawn with ITK-SNAP, using Active Contour Segmentation. Each anatomic structure is identified by a label number. Registration is performed using Elastix, using Mutual Information and an Adaptive Stochastic Gradient optimization. The dataset consists of the MRL scans of ten patients, with lymph nodes manually annotated in consensus by two expert readers. The feature map of the CAD system consists of the Multi-Atlas and various other features (e.g. Normalized Intensity and multi-scale Blobness). The voxel-based Gentleboost classifier is evaluated using ROC analysis with cross validation. We show in a set of 10 studies that adding multi-structure, multi-atlas anatomical structure likelihood features improves the quality of the lymph node voxel likelihood map. Multiple structure anatomy maps may thus make MRL CAD more feasible.

  17. An intelligent pre-processing framework for standardizing medical images for CAD and other post-processing applications

    NASA Astrophysics Data System (ADS)

    Raghupathi, Lakshminarasimhan; Devarakota, Pandu R.; Wolf, Matthias

    2012-03-01

    There is an increasing need to provide end-users with seamless and secure access to healthcare information acquired from a diverse range of sources. This might include local and remote hospital sites equipped with different vendors and practicing varied acquisition protocols and also heterogeneous external sources such as the Internet cloud. In such scenarios, image post-processing tools such as CAD (computer-aided diagnosis) which were hitherto developed using a smaller set of images may not always work optimally on newer set of images having entirely different characteristics. In this paper, we propose a framework that assesses the quality of a given input image and automatically applies an appropriate pre-processing method in such a manner that the image characteristics are normalized regardless of its source. We focus mainly on medical images, and the objective of the said preprocessing method is to standardize the performance of various image processing and workflow applications like CAD to perform in a consistent manner. First, our system consists of an assessment step wherein an image is evaluated based on criteria such as noise, image sharpness, etc. Depending on the measured characteristic, we then apply an appropriate normalization technique thus giving way to our overall pre-processing framework. A systematic evaluation of the proposed scheme is carried out on large set of CT images acquired from various vendors including images reconstructed with next generation iterative methods. Results demonstrate that the images are normalized and thus suitable for an existing LungCAD prototype1.

  18. Effectiveness of Computer-Aided Detection in Community Mammography Practice

    PubMed Central

    Abraham, Linn; Taplin, Stephen H.; Geller, Berta M.; Carney, Patricia A.; D’Orsi, Carl; Elmore, Joann G.; Barlow, William E.

    2011-01-01

    Background Computer-aided detection (CAD) is applied during screening mammography for millions of US women annually, although it is uncertain whether CAD improves breast cancer detection when used by community radiologists. Methods We investigated the association between CAD use during film-screen screening mammography and specificity, sensitivity, positive predictive value, cancer detection rates, and prognostic characteristics of breast cancers (stage, size, and node involvement). Records from 684 956 women who received more than 1.6 million film-screen mammograms at Breast Cancer Surveillance Consortium facilities in seven states in the United States from 1998 to 2006 were analyzed. We used random-effects logistic regression to estimate associations between CAD and specificity (true-negative examinations among women without breast cancer), sensitivity (true-positive examinations among women with breast cancer diagnosed within 1 year of mammography), and positive predictive value (breast cancer diagnosed after positive mammograms) while adjusting for mammography registry, patient age, time since previous mammography, breast density, use of hormone replacement therapy, and year of examination (1998–2002 vs 2003–2006). All statistical tests were two-sided. Results Of 90 total facilities, 25 (27.8%) adopted CAD and used it for an average of 27.5 study months. In adjusted analyses, CAD use was associated with statistically significantly lower specificity (OR = 0.87, 95% confidence interval [CI] = 0.85 to 0.89, P < .001) and positive predictive value (OR = 0.89, 95% CI = 0.80 to 0.99, P = .03). A non-statistically significant increase in overall sensitivity with CAD (OR = 1.06, 95% CI = 0.84 to 1.33, P = .62) was attributed to increased sensitivity for ductal carcinoma in situ (OR = 1.55, 95% CI = 0.83 to 2.91; P = .17), although sensitivity for invasive cancer was similar with or without CAD (OR = 0.96, 95% CI = 0.75 to 1.24; P = .77). CAD was not associated with

  19. Advances in computer-aided design and computer-aided manufacture technology.

    PubMed

    Calamia, J R

    1996-01-01

    Although the development of computer-aided design (CAD) and computer-aided manufacture (CAM) technology and the benefits of increased productivity became obvious in the automobile and aerospace industries in the 1970s, investigations of this technology's application in the field of dentistry did not begin until the 1980s. Only now are we beginning to see the fruits of this work with the commercial availability of some systems; the potential for this technology seems boundless. This article reviews the recent literature with emphasis on the period from June 1992 to May 1993. This review should familiarize the reader with some of the latest developments in this technology, including a brief description of some systems currently available and the clinical and economical rationale for their acceptance into the dental mainstream. This article concentrates on a particular system, the Cerec (Siemens/Pelton and Crane, Charlotte, NC) system, for three reasons: First, this system has been available since 1985 and, as a result, has a track record of almost 7 years of data. Most of the data have just recently been released and consequently, much of this year's literature on CAD-CAM is monopolized by studies using this system. Second, this system was developed as a mobile, affordable, direct chairside CAD-CAM restorative method. As such, it is of special interest to the patient, providing a one-visit restoration. Third, the author is currently engaged in research using this particular system and has a working knowledge of this system's capabilities.

  20. Learning-based image preprocessing for robust computer-aided detection

    NASA Astrophysics Data System (ADS)

    Raghupathi, Laks; Devarakota, Pandu R.; Wolf, Matthias

    2013-03-01

    Recent studies have shown that low dose computed tomography (LDCT) can be an effective screening tool to reduce lung cancer mortality. Computer-aided detection (CAD) would be a beneficial second reader for radiologists in such cases. Studies demonstrate that while iterative reconstructions (IR) improve LDCT diagnostic quality, it however degrades CAD performance significantly (increased false positives) when applied directly. For improving CAD performance, solutions such as retraining with newer data or applying a standard preprocessing technique may not be suffice due to high prevalence of CT scanners and non-uniform acquisition protocols. Here, we present a learning-based framework that can adaptively transform a wide variety of input data to boost an existing CAD performance. This not only enhances their robustness but also their applicability in clinical workflows. Our solution consists of applying a suitable pre-processing filter automatically on the given image based on its characteristics. This requires the preparation of ground truth (GT) of choosing an appropriate filter resulting in improved CAD performance. Accordingly, we propose an efficient consolidation process with a novel metric. Using key anatomical landmarks, we then derive consistent feature descriptors for the classification scheme that then uses a priority mechanism to automatically choose an optimal preprocessing filter. We demonstrate CAD prototype∗ performance improvement using hospital-scale datasets acquired from North America, Europe and Asia. Though we demonstrated our results for a lung nodule CAD, this scheme is straightforward to extend to other post-processing tools dedicated to other organs and modalities.

  1. Indications for Computer-Aided Design and Manufacturing in Congenital Craniofacial Reconstruction.

    PubMed

    Fisher, Mark; Medina, Miguel; Bojovic, Branko; Ahn, Edward; Dorafshar, Amir H

    2016-09-01

    The complex three-dimensional relationships in congenital craniofacial reconstruction uniquely lend themselves to the ability to accurately plan and model the result provided by computer-aided design and manufacturing (CAD/CAM). The goal of this study was to illustrate indications where CAD/CAM would be helpful in the treatment of congenital craniofacial anomalies reconstruction and to discuss the application of this technology and its outcomes. A retrospective review was performed of all congenital craniofacial cases performed by the senior author between 2010 and 2014. Cases where CAD/CAM was used were identified, and illustrative cases to demonstrate the benefits of CAD/CAM were selected. Preoperative appearance, computerized plan, intraoperative course, and final outcome were analyzed. Preoperative planning enabled efficient execution of the operative plan with predictable results. Risk factors which made these patients good candidates for CAD/CAM were identified and compiled. Several indications, including multisuture and revisional craniosynostosis, facial bipartition, four-wall box osteotomy, reduction cranioplasty, and distraction osteogenesis could benefit most from this technology. We illustrate the use of CAD/CAM for these applications and describe the decision-making process both before and during surgery. We explore why we believe that CAD/CAM is indicated in these scenarios as well as the disadvantages and risks. PMID:27516839

  2. Indications for Computer-Aided Design and Manufacturing in Congenital Craniofacial Reconstruction.

    PubMed

    Fisher, Mark; Medina, Miguel; Bojovic, Branko; Ahn, Edward; Dorafshar, Amir H

    2016-09-01

    The complex three-dimensional relationships in congenital craniofacial reconstruction uniquely lend themselves to the ability to accurately plan and model the result provided by computer-aided design and manufacturing (CAD/CAM). The goal of this study was to illustrate indications where CAD/CAM would be helpful in the treatment of congenital craniofacial anomalies reconstruction and to discuss the application of this technology and its outcomes. A retrospective review was performed of all congenital craniofacial cases performed by the senior author between 2010 and 2014. Cases where CAD/CAM was used were identified, and illustrative cases to demonstrate the benefits of CAD/CAM were selected. Preoperative appearance, computerized plan, intraoperative course, and final outcome were analyzed. Preoperative planning enabled efficient execution of the operative plan with predictable results. Risk factors which made these patients good candidates for CAD/CAM were identified and compiled. Several indications, including multisuture and revisional craniosynostosis, facial bipartition, four-wall box osteotomy, reduction cranioplasty, and distraction osteogenesis could benefit most from this technology. We illustrate the use of CAD/CAM for these applications and describe the decision-making process both before and during surgery. We explore why we believe that CAD/CAM is indicated in these scenarios as well as the disadvantages and risks.

  3. Development of a web-based DICOM-SR viewer for CAD data of multiple sclerosis lesions in an imaging informatics-based efolder

    NASA Astrophysics Data System (ADS)

    Ma, Kevin; Wong, Jonathan; Zhong, Mark; Zhang, Jeff; Liu, Brent

    2014-03-01

    In the past, we have presented an imaging-informatics based eFolder system for managing and analyzing imaging and lesion data of multiple sclerosis (MS) patients, which allows for data storage, data analysis, and data mining in clinical and research settings. The system integrates the patient's clinical data with imaging studies and a computer-aided detection (CAD) algorithm for quantifying MS lesion volume, lesion contour, locations, and sizes in brain MRI studies. For compliance with IHE integration protocols, long-term storage in PACS, and data query and display in a DICOM compliant clinical setting, CAD results need to be converted into DICOM-Structured Report (SR) format. Open-source dcmtk and customized XML templates are used to convert quantitative MS CAD results from MATLAB to DICOM-SR format. A web-based GUI based on our existing web-accessible DICOM object (WADO) image viewer has been designed to display the CAD results from generated SR files. The GUI is able to parse DICOM-SR files and extract SR document data, then display lesion volume, location, and brain matter volume along with the referenced DICOM imaging study. In addition, the GUI supports lesion contour overlay, which matches a detected MS lesion with its corresponding DICOM-SR data when a user selects either the lesion or the data. The methodology of converting CAD data in native MATLAB format to DICOM-SR and displaying the tabulated DICOM-SR along with the patient's clinical information, and relevant study images in the GUI will be demonstrated. The developed SR conversion model and GUI support aim to further demonstrate how to incorporate CAD post-processing components in a PACS and imaging informatics-based environment.

  4. Tolerancing of component dimensions in CAD

    NASA Astrophysics Data System (ADS)

    Parkinson, D. B.

    1984-01-01

    Any particular dimension of a manufactured component varies in its value between individual nominally identical components. When several components are to be assembled together, it can happen that in some cases assembly will prove impossible, or that the assembly may not satisfy design specifications. The problem arises to optimize dimensional tolerances to ensure that, for given manufacturing costs, there is an acceptably low risk of the assembly failing to meet the specification. Approaches for solving this problem are discussed. The ability to associate a chosen set of nominal dimensions and dimensional tolerances with a numerical estimate of the risk of unsatisfactory assembly is found to be of considerable value in computer-aided design procedures, where it is necessary to optimize tolerances for minimum overall cost.

  5. 46 CFR 169.755 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SCHOOL VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.755 Draft marks and... necessary for easy observance. The bottom of each mark must indicate the draft. (b) The draft must be...

  6. 46 CFR 78.50-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... draft marks plainly and legibly visible upon the stem and upon the sternpost or rudderpost or any place... of the draft marks, due to raked stem or cut—away skeg, the datum line from which the draft shal...

  7. 46 CFR 167.55-1 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) All vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or... aft to the location of the draft marks, due to a raked stem or cut away skeg, the draft must...

  8. 46 CFR 78.50-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... draft marks plainly and legibly visible upon the stem and upon the sternpost or rudderpost or any place... of the draft marks, due to raked stem or cut—away skeg, the datum line from which the draft shal...

  9. 46 CFR 78.50-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... draft marks plainly and legibly visible upon the stem and upon the sternpost or rudderpost or any place... of the draft marks, due to raked stem or cut—away skeg, the datum line from which the draft shal...

  10. AIDS lymphomas.

    PubMed

    Middleton, G W; Lau, R K

    1992-01-01

    Chronically immunosuppressed individuals are susceptible to lymphoreticular tumors. Up to 15% of patients with congenital deficiencies such as ataxia=telangiectasia may develop malignancies, mainly high-grade B cell non=Hodgkin's lymphomas (NHLs). AIDS lymphomas are comprised of NHLs including Burkitt's lymphoma (BL) and primary cerebral lymphomas (PCLs). Almost 3% of all AIDS patients (2824 of 97,258 cases) developed NHL. Epstein-Barr virus (EBV) as a co-factor in AIDS lymphomagenesis has been studied: in 12 cases of 24 AIDS lymphomas EBV by DNA in situ hybridization was found. In an analysis of 6 primary cerebral lymphomas, .5 were positive for EBV DNA by Southern blotting. In Burkitt's lymphoma the characteristic genetic alteration affects the c-myc oncogene. In 1/3 of BL p53 mutations were found but none in the 43 NHLs suggesting that p53 mutations and c-myc activation act synergistically in the pathogenesis of these tumors. Cytotoxic agents dideoxyinosine, dideoxycytosine, and zidovudine may cause secondary neoplasia. 8 of 55 AIDS patients under zidovudine treatment developed high-grade lymphoma 23.8 months subsequently; recently doses were reduced. PCL was found in 21 of 90 patients. A 5.2 months survival was associated with combined treatment with cyclophosphamide, Oncovin (vincristine), methotrexate, etoposide, and cytosine arabinoside compared with 11.3 months with chemotherapy. Colony-stimulating factors (CSFs) alleviate drug-induced myelotoxicity and zidovudine-induced neutropenia, however, l8 of 11 patients receiving granulocyte-macrophage CSF developed hematological toxicity. Interleukine-2 produced by T-helper cells enhancing tumor cells cytotoxicity has been used in AIDS-associated cryptosporidial diarrhea and in 4 patients with AIDS lymphoma with modest response, but its stimulation of the HIV-infected substrate may increase viral proliferation.

  11. Study of medium beta elliptical cavities for CADS

    NASA Astrophysics Data System (ADS)

    Wen, Liangjian; Zhang, Shenghu; Li, Yongming; Wang, Ruoxu; Guo, Hao; Zhang, Cong; Jia, Huan; Jiang, Tiancai; Li, Chunlong; He, Yuan

    2016-02-01

    The China Accelerator-Driven Sub-critical System (CADS) is a high intensity proton facility to dispose of nuclear waste and generate electric power. CADS is based on a 1.5 GeV, 10 mA CW superconducting (SC) linac as a driver. The high energy section of the linac is composed of two families of SC elliptical cavities which are designed with geometrical beta 0.63 and 0.82. In this paper, the 650 MHz β=0.63 SC elliptical cavity is studied, including cavity optimization, multipacting, high order modes (HOMs) and generator RF power calculation. Supported by National Natural Science Foundation of China (91426303)

  12. Chairside CAD/CAM: an overview of restorative material options.

    PubMed

    Fasbinder, Dennis J

    2012-01-01

    A number of categories of materials are available for chairside CAD/CAM restorations that have demonstrated predictability and longevity. These materials include esthetic and high-strength ceramics, composite resins for both final and temporary restorations, and newer nanoceramics that offer ease of handling and a glossy surface finish. Each category of materials has unique features designed for specific clinical applications. This article will examine currently available materials designed for chairside CAD/CAM restorations and the various outcomes that are possible with this technologically advanced process.

  13. Impact of IPAD on CAD/CAM database university research

    NASA Technical Reports Server (NTRS)

    Leach, L. M.; Wozny, M. J.

    1984-01-01

    IPAD program has provided direction, focus and software products which impacted on CAD/CAM data base research and follow-on research. The relationship of IPAD to the research projects which involve the storage of geometric data in common data ase facilities such as data base machines, the exchange of data between heterogeneous data bases, the development of IGES processors, the migration of lrge CAD/CAM data base management systems to noncompatible hosts, and the value of RIM as a research tool is described.

  14. Development to integrate conceptual design tools and a CAD system

    NASA Astrophysics Data System (ADS)

    Torres, V. H.; Ríos, J.; Vizán, A.; Pérez, J. M.

    2012-04-01

    The information supported by PLM/CAD systems is mainly related to Embodiment and Detail Design Phases. Information related to the Conceptual Design Phase is mainly limited to requirement specification documents and system architecture diagram documents. This work aims helping in the integration of the Conceptual Design process and its associated information flow into a commercial software system. It proposes a development framework to integrate Quality Function Deployment, Axiomatic Design, and Failure Mode and Effects Analysis into a PLM/CAD system. This communication presents the methodology used in the development, the software development environment, the modeling of the proposed application and the first results of a pilot implementation.

  15. 78 FR 46952 - Relief-Mart, Inc.; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-02

    ... Marketing Claims, 77 FR 62, 122, 62,123 (Oct. 11, 2012). Parts III though VI require Relief-Mart to: Keep... Relief-Mart, Inc.; Analysis of Proposed Consent Order To Aid Public Comment AGENCY: Federal Trade.... The attached Analysis to Aid Public Comment describes both the allegations in the draft complaint...

  16. 77 FR 12591 - THV Holdings LLC; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-01

    ... Holdings LLC; Analysis of Proposed Consent Order To Aid Public Comment AGENCY: Federal Trade Commission.... The attached Analysis to Aid Public Comment describes both the allegations in the draft complaint and... Commission, has been placed on the public record for a period of thirty (30) days. The following Analysis...

  17. 77 FR 12588 - Long Fence & Home, LLLP; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-01

    ... Long Fence & Home, LLLP; Analysis of Proposed Consent Order To Aid Public Comment AGENCY: Federal Trade.... The attached Analysis to Aid Public Comment describes both the allegations in the draft complaint and... Commission, has been placed on the public record for a period of thirty (30) days. The following Analysis...

  18. 77 FR 12586 - Serious Energy, Inc.; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-01

    ... Serious Energy, Inc.; Analysis of Proposed Consent Order To Aid Public Comment AGENCY: Federal Trade.... The attached Analysis To Aid Public Comment describes both the allegations in the draft complaint and... Commission, has been placed on the public record for a period of thirty (30) days. The following Analysis...

  19. Draft Genome Sequence of Kocuria rhizophila RF, a Radiation-Resistant Soil Isolate

    PubMed Central

    Mehrabadi, Jalil Fallah; Mirzaie, Amir; Ahangar, Nahid; Rahimi, Arian

    2016-01-01

    Kocuria rhizophila RF, a soil isolate from Iran, is a radiation-resistant bacterium. Only a limited amount of genomic information for radiation-resistant bacteria is currently available. Here, we report the draft genome sequence of this bacterium, providing knowledge to aid in the discovery of the genomic basis of its resistance to radiation. PMID:26966202

  20. Draft Genome Sequence of the Tyramine Producer Enterococcus durans Strain IPLA 655

    PubMed Central

    Ladero, Victor; Linares, Daniel M.; del Rio, Beatriz; Fernandez, Maria; Martin, M. Cruz

    2013-01-01

    We here report a 3.059-Mbp draft assembly for the genome of Enterococcus durans strain IPLA 655. This dairy isolate provides a model for studying the regulation of the biosynthesis of tyramine (a toxic compound). These results should aid our understanding of tyramine production and allow tyramine accumulation in food to be reduced. PMID:23682153

  1. The prediction of breast cancer biopsy outcomes using two CAD approaches that both emphasize an intelligible decision process

    SciTech Connect

    Elter, M.; Schulz-Wendtland, R.; Wittenberg, T.

    2007-11-15

    Mammography is the most effective method for breast cancer screening available today. However, the low positive predictive value of breast biopsy resulting from mammogram interpretation leads to approximately 70% unnecessary biopsies with benign outcomes. To reduce the high number of unnecessary breast biopsies, several computer-aided diagnosis (CAD) systems have been proposed in the last several years. These systems help physicians in their decision to perform a breast biopsy on a suspicious lesion seen in a mammogram or to perform a short term follow-up examination instead. We present two novel CAD approaches that both emphasize an intelligible decision process to predict breast biopsy outcomes from BI-RADS findings. An intelligible reasoning process is an important requirement for the acceptance of CAD systems by physicians. The first approach induces a global model based on decison-tree learning. The second approach is based on case-based reasoning and applies an entropic similarity measure. We have evaluated the performance of both CAD approaches on two large publicly available mammography reference databases using receiver operating characteristic (ROC) analysis, bootstrap sampling, and the ANOVA statistical significance test. Both approaches outperform the diagnosis decisions of the physicians. Hence, both systems have the potential to reduce the number of unnecessary breast biopsies in clinical practice. A comparison of the performance of the proposed decision tree and CBR approaches with a state of the art approach based on artificial neural networks (ANN) shows that the CBR approach performs slightly better than the ANN approach, which in turn results in slightly better performance than the decision-tree approach. The differences are statistically significant (p value <0.001). On 2100 masses extracted from the DDSM database, the CRB approach for example resulted in an area under the ROC curve of A(z)=0.89{+-}0.01, the decision-tree approach in A(z)=0

  2. Transcriptome-wide identification and characterization of CAD isoforms specific for podophyllotoxin biosynthesis from Podophyllum hexandrum.

    PubMed

    Bhattacharyya, Dipto; Hazra, Saptarshi; Banerjee, Anindyajit; Datta, Riddhi; Kumar, Deepak; Chakrabarti, Saikat; Chattopadhyay, Sharmila

    2016-09-01

    Podophyllotoxin (ptox) is a therapeutically important lignan derived from Podophyllum hexandrum and is used as a precursor for the synthesis of anticancer drugs etoposide, teniposide and etopophose. In spite of its enormous economic significance, genomic information on this endangered medicinal herb is scarce. We have performed de novo transcriptome analysis of methyl jasmonate (MeJA)-treated P. hexandrum cell cultures exhibiting enhanced ptox accumulation. The results revealed the maximum up-regulation of several isoforms of cinnamyl alcohol dehydrogenase (CAD). CAD catalyzes the synthesis of coniferyl alcohol and sinapyl alcohol from coniferaldehyde (CAld) and sinapaldehyde respectively. Coniferyl alcohol can produce both lignin and lignan while sinapyl alcohol produces only lignin. To isolate the CAD isoforms favoring ptox, we deduced full length cDNA sequences of four CAD isoforms: PhCAD1, PhCAD2, PhCAD3 and PhCAD4 from the contigs of the transcriptome data. In vitro enzyme assays indicated a higher affinity for CAld over sinapaldehyde for each isoform. In silico molecular docking analyses also suggested that PhCAD3 has a higher binding preference with CAld over sinapaldehyde, followed by PhCAD4, PhCAD2, and PhCAD1, respectively. The transgenic cell cultures overexpressing these isoforms independently revealed that PhCAD3 favored the maximum accumulation of ptox as compared to lignin followed by PhCAD4 and PhCAD2, whereas, PhCAD1 favored both equally. Together, our study reveals transcriptome-wide identification and characterization of ptox specific CAD isoforms from P. hexandrum. It provides a useful resource for future research not only on the ptox biosynthetic pathway but on overall P. hexandrum, an endangered medicinal herb with immense therapeutic importance.

  3. Confronting AIDS.

    PubMed

    Squire, L

    1998-03-01

    By 2020, HIV/AIDS will be the leading infectious killer of young and middle-aged adults in the developing world. Past gains in life expectancy are already being eroded in some countries. Millions of lives can, however, be saved if developing country governments, the international community, and nongovernmental organizations act now. Although more than 11 million people have already died of AIDS, 2.3 billion people live in developing countries in which the disease has not yet spread beyond certain risk groups. If the spread of HIV is checked, the quality of care available to people who are infected with HIV will probably be better than it would be in the context of a full-blown AIDS epidemic. However, while governments need to respond urgently to HIV/AIDS, using resources to help people with AIDS will reduce the resources available for other investments, such as child education, providing safe drinking water, and building roads. Economics can help governments set priorities as they decide how best to allocate their available resources. Externalities, public goods, and redistribution are discussed. All countries will need to use some combination of preventive and coping measures. PMID:12293445

  4. Enhanced cadaverine production from L-lysine using recombinant Escherichia coli co-overexpressing CadA and CadB.

    PubMed

    Ma, Weichao; Cao, Weijia; Zhang, Hong; Chen, Kequan; Li, Yan; Ouyang, Pingkai

    2015-04-01

    The effect of fusing the PelB signal sequence to lysine/cadaverine antiporter (CadB) on the bioconversion of L-lysine to cadaverine was investigated. To construct a whole-cell biocatalyst for cadaverine production, four expression plasmids were constructed for the co-expression of lysine decarboxylase (CadA) and lysine/cadaverine antiporter (CadB) in Escherichia coli. Expressing CadB with the PelB signal sequence increased cadaverine production by 12%, and the optimal expression plasmid, pETDuet-pelB-CadB-CadA, contained two T7 promoter-controlled genes, CadA and the PelB-CadB fusion protein. Based on pETDuet-pelB-CadB-CadA, a whole-cell system for the bioconversion of L-lysine to cadaverine was constructed, and three strategies for L-lysine feeding were evaluated to eliminate the substrate inhibition problem. A cadaverine titer of 221 g l(-1) with a molar yield of 92% from lysine was obtained. PMID:25515797

  5. Computer-aided dental prostheses construction using reverse engineering.

    PubMed

    Solaberrieta, E; Minguez, R; Barrenetxea, L; Sierra, E; Etxaniz, O

    2014-01-01

    The implementation of computer-aided design/computer-aided manufacturing (CAD/CAM) systems with virtual articulators, which take into account the kinematics, constitutes a breakthrough in the construction of customised dental prostheses. This paper presents a multidisciplinary protocol involving CAM techniques to produce dental prostheses. This protocol includes a step-by-step procedure using innovative reverse engineering technologies to transform completely virtual design processes into customised prostheses. A special emphasis is placed on a novel method that permits a virtual location of the models. The complete workflow includes the optical scanning of the patient, the use of reverse engineering software and, if necessary, the use of rapid prototyping to produce CAD temporary prostheses.

  6. Computer-aided design of polymers and composites

    NASA Technical Reports Server (NTRS)

    Kaelble, D. H.

    1985-01-01

    This book on computer-aided design of polymers and composites introduces and discusses the subject from the viewpoint of atomic and molecular models. Thus, the origins of stiffness, strength, extensibility, and fracture toughness in composite materials can be analyzed directly in terms of chemical composition and molecular structure. Aspects of polymer composite reliability are considered along with characterization techniques for composite reliability, relations between atomic and molecular properties, computer aided design and manufacture, polymer CAD/CAM models, and composite CAD/CAM models. Attention is given to multiphase structural adhesives, fibrous composite reliability, metal joint reliability, polymer physical states and transitions, chemical quality assurance, processability testing, cure monitoring and management, nondestructive evaluation (NDE), surface NDE, elementary properties, ionic-covalent bonding, molecular analysis, acid-base interactions, the manufacturing science, and peel mechanics.

  7. The use of CAD/CAM technology to fabricate a custom ceramic implant abutment: a clinical report.

    PubMed

    Bertolini, Martinna de Mendonça e; Kempen, Juan; Lourenço, Eduardo José Veras; Telles, Daniel de Moraes

    2014-05-01

    Well-placed dental implants are a prerequisite of functional and esthetically successful dental implant-supported crowns. The presence of soft tissue is essential for excellent esthetics because the dental implant or titanium abutment may become visible if the soft-tissue contour is not acceptable. This clinical report describes the use of a custom ceramic implant abutment designed with computer-aided design and computer-aided manufacturing (CAD/CAM) technology by milling a zirconia framework that was cemented extraorally to a prefabricated titanium abutment with a reduced diameter. This ceramic abutment has the strength and precise fit of a titanium interface and also the esthetic advantages of shaded custom-milled zirconia, with no visible metal. PMID:24433839

  8. The use of CAD/CAM technology to fabricate a custom ceramic implant abutment: a clinical report.

    PubMed

    Bertolini, Martinna de Mendonça e; Kempen, Juan; Lourenço, Eduardo José Veras; Telles, Daniel de Moraes

    2014-05-01

    Well-placed dental implants are a prerequisite of functional and esthetically successful dental implant-supported crowns. The presence of soft tissue is essential for excellent esthetics because the dental implant or titanium abutment may become visible if the soft-tissue contour is not acceptable. This clinical report describes the use of a custom ceramic implant abutment designed with computer-aided design and computer-aided manufacturing (CAD/CAM) technology by milling a zirconia framework that was cemented extraorally to a prefabricated titanium abutment with a reduced diameter. This ceramic abutment has the strength and precise fit of a titanium interface and also the esthetic advantages of shaded custom-milled zirconia, with no visible metal.

  9. Present State of CAD Teaching in Spanish Universities

    ERIC Educational Resources Information Center

    Garcia, Ramon Rubio; Santos, Ramon Gallego; Quiros, Javier Suarez; Penin, Pedro I. Alvarez

    2005-01-01

    During the 1990s, all Spanish Universities updated the syllabuses of their courses as a result of the entry into force of the new Organic Law of Universities ("Ley Organica de Universidades") and, for the first time, "Computer Assisted Design" (CAD) appears in the list of core subjects (compulsory teaching content set by the government) in many of…

  10. Introduction to CAD/Computers. High-Technology Training Module.

    ERIC Educational Resources Information Center

    Lockerby, Hugh

    This learning module for an eighth-grade introductory technology course is designed to help teachers introduce students to computer-assisted design (CAD) in a communications unit on graphics. The module contains a module objective and five specific objectives, a content outline, suggested instructor methodology, student activities, a list of six…

  11. The design and construction of the CAD-1 airship

    NASA Technical Reports Server (NTRS)

    Kleiner, H. J.; Schneider, R.; Duncan, J. L.

    1975-01-01

    The background history, design philosophy and Computer application as related to the design of the envelope shape, stress calculations and flight trajectories of the CAD-1 airship, now under construction by Canadian Airship Development Corporation are reported. A three-phase proposal for future development of larger cargo carrying airships is included.

  12. Including CAD/CAM dentistry in a dental school curriculum.

    PubMed

    Browning, William D; Reifeis, Paul; Willis, Lisa; Kirkup, Michele L

    2013-01-01

    Shaping a clinical curriculum that is appropriate for novice dentists, is based on high-quality evidence of efficacy, yet reflects current practices is challenging. CAD/CAM units have been available to dentists since the late '80s. Recent improvements in the software, hardware and the clinical performance of available all-ceramic blocks have keyed a surge in interest. Based on a careful review of the systems available and, equally importantly, a review of the research regarding the longevity of reinforced glass ceramics, IUSD decided to add training on the use of the E4D CAD/CAM system to the curriculum. Students now receive lectures, preclinical hands-on training and clinical experience in fabricating all-ceramic restorations. At present any student who is interested in providing an all-ceramic restoration for his/her patient can do so using our CAD/CAM system. In a little less than one year our undergraduate dental students have provided 125 all-ceramic crowns to their patients. Clinical faculty have been impressed with the marginal fit and esthetics of the crowns. Finally, with students designing, milling, sintering and staining the restorations the CAD/CAM systems has reduced lab costs significantly.

  13. Right approach to 3D modeling using CAD tools

    NASA Astrophysics Data System (ADS)

    Baddam, Mounica Reddy

    The thesis provides a step-by-step methodology to enable an instructor dealing with CAD tools to optimally guide his/her students through an understandable 3D modeling approach which will not only enhance their knowledge about the tool's usage but also enable them to achieve their desired result in comparatively lesser time. In the known practical field, there is particularly very little information available to apply CAD skills to formal beginners' training sessions. Additionally, advent of new software in 3D domain cumulates updating into a more difficult task. Keeping up to the industry's advanced requirements emphasizes the importance of more skilled hands in the field of CAD development, rather than just prioritizing manufacturing in terms of complex software features. The thesis analyses different 3D modeling approaches specified to the varieties of CAD tools currently available in the market. Utilizing performance-time databases, learning curves have been generated to measure their performance time, feature count etc. Based on the results, improvement parameters have also been provided for (Asperl, 2005).

  14. Draft Wetlands Rule Released

    NASA Astrophysics Data System (ADS)

    Zielinski, Sarah

    2006-04-01

    The U.S. Environmental Protection Agency (EPA) and the U.S. Army Corps of Engineers released on 28 March a draft of a new rule to guide compensatory mitigation for when wetlands are unavoidably lost due to development. However, whether the rule is successful in preventing a net loss in wetlands will depend largely on its implementation, according to two wetlands scientists who evaluated the issue for the U.S. National Research Council (NRC) in 2001. Under the federal Clean Water Act, developers who seek to build on wetlands must compensate for any wetlands loss if they are unable to avoid or minimize the loss. Such compensation is covered under the newly proposed compensatory mitigation rule. Benjamin Grumbles, EPA assistant administrator for water, called the rule an ``innovative new standard that will accelerate the pace of wetlands conservation and restoration.''

  15. Research on remote sensing image pixel attribute data acquisition method in AutoCAD

    NASA Astrophysics Data System (ADS)

    Liu, Xiaoyang; Sun, Guangtong; Liu, Jun; Liu, Hui

    2013-07-01

    The remote sensing image has been widely used in AutoCAD, but AutoCAD lack of the function of remote sensing image processing. In the paper, ObjectARX was used for the secondary development tool, combined with the Image Engine SDK to realize remote sensing image pixel attribute data acquisition in AutoCAD, which provides critical technical support for AutoCAD environment remote sensing image processing algorithms.

  16. Aesthetic and functionality in fixed prosthodontic: sperimental and clinical analysis of the CAD-CAM systematic 3Shape

    PubMed Central

    DE VICO, G.; OTTRIA, L.; BOLLERO, P.; BONINO, M.; CIALONE, M.; BARLATTANI, A.; GARGARI, M.

    2009-01-01

    SUMMARY In the last 15 years the increasing aesthetic demand, push constantly industry and the clinical to entirely look for new solutions for the realization of all-ceramic crowns, with such characteristics to be used for both anterior and posterior restorations. The most greater contribution, in such sense derives from the finished progress in the computer sector, that have allowed the application of the technologies CAD-CAM, also in dentistry (2–5, 11). These systematics have allowed us to get “automatically” structures for dental prosthesis, starting from the scanning of the die and passing for an intermediary phase of computerized planning (CAD, computer aided design), through numerical control millers (CAM, computer aided manufacturing), enslaved to calculating the electronic that drives the movement of it. The aim of this work is therefore that to analyze and to describe the systematic computerized 3SHAPE verifying the degree of precision, through the analysis of the obtainable marginal closing with the zirconia frameworks. PMID:23285346

  17. Accuracy of fibular sectioning and insertion into a rapid-prototyped bone plate, for mandibular reconstruction using CAD-CAM technology.

    PubMed

    Ciocca, Leonardo; Marchetti, Claudio; Mazzoni, Simona; Baldissara, Paolo; Gatto, Maria Rosaria Antonella; Cipriani, Riccardo; Scotti, Roberto; Tarsitano, Achille

    2015-01-01

    Modern techniques of mandibular reconstruction, such as CAD-CAM technology and rapid prototyping, offer new means by which reconstructive surgery can be planned to optimise aesthetic outcomes and prosthetic rehabilitation. The high degree of accuracy afforded by these approaches is principally attributable to high-precision fibular sectioning and insertion of the bone into a customised bone plate. CAD-CAM mandibular reconstruction procedures using vascularised bone free-flap transfers were performed on 10 patients with benign or malignant neoplasms. Five were not treated with the aid of CAD-CAM technology, and served as the control group. Five were scheduled for maxillofacial surgery using surgical cutting guides and customised bone plates. A generalised linear model for linear measures was used to compare the accuracy of reconstruction between the two groups. A difference, even though not significant, in the lateral shift of the mesial and distal positions of the fibular units was evident between groups. CAD-CAM-generated fibular surgical guides afford improved accuracy when used to restore native anatomy, especially in the context of mandibular arch restoration, and both operating room time and related costs are reduced during fibular sectioning. PMID:25434288

  18. Impact of Computer-Aided Detection Systems on Radiologist Accuracy With Digital Mammography

    PubMed Central

    Cole, Elodia B.; Zhang, Zheng; Marques, Helga S.; Hendrick, R. Edward; Yaffe, Martin J.; Pisano, Etta D.

    2014-01-01

    OBJECTIVE The purpose of this study was to assess the impact of computer-aided detection (CAD) systems on the performance of radiologists with digital mammograms acquired during the Digital Mammographic Imaging Screening Trial (DMIST). MATERIALS AND METHODS Only those DMIST cases with proven cancer status by biopsy or 1-year follow-up that had available digital images were included in this multireader, multicase ROC study. Two commercially available CAD systems for digital mammography were used: iCAD SecondLook, version 1.4; and R2 ImageChecker Cenova, version 1.0. Fourteen radiologists interpreted, without and with CAD, a set of 300 cases (150 cancer, 150 benign or normal) on the iCAD SecondLook system, and 15 radiologists interpreted a different set of 300 cases (150 cancer, 150 benign or normal) on the R2 ImageChecker Cenova system. RESULTS The average AUC was 0.71 (95% CI, 0.66–0.76) without and 0.72 (95% CI, 0.67–0.77) with the iCAD system (p = 0.07). Similarly, the average AUC was 0.71 (95% CI, 0.66–0.76) without and 0.72 (95% CI 0.67–0.77) with the R2 system (p = 0.08). Sensitivity and specificity differences without and with CAD for both systems also were not significant. CONCLUSION Radiologists in our studies rarely changed their diagnostic decisions after the addition of CAD. The application of CAD had no statistically significant effect on radiologist AUC, sensitivity, or specificity performance with digital mammograms from DMIST. PMID:25247960

  19. Classroom Aids

    ERIC Educational Resources Information Center

    Science Activities: Classroom Projects and Curriculum Ideas, 2007

    2007-01-01

    This article describes 6 aids for science instruction, including (1) the use of fudge to represent lava; (2) the "Living by Chemistry" program, designed to make high school chemistry more accessible to a diverse pool of students without sacrificing content; (3) NOAA and NSTA's online coral reef teaching tool, a new web-based "science toolbox" for…

  20. Dietitian Aide.

    ERIC Educational Resources Information Center

    Texas Tech. Univ., Lubbock. School of Home Economics.

    This course of study for the dietitian aide is one of a series available for use by teacher-coordinators and students in Grade 11 and 12 home economics cooperative education programs. Based on job analysis interviews with health care facilities personnel, this course was prepared by teachers and Instructional Materials Center staff, field-tested,…

  1. Floriculture Aide.

    ERIC Educational Resources Information Center

    Martin, Joyce; Looney, Era

    Designed for use in a self-paced, open-entry/open-exit vocational training program for a floriculture aide, this program guide is one of six for teachers of adult women offenders from a correctional institution. Module topic outlines and sample lesson plans are presented on eleven topics: occupational opportunities in the retail florist industry;…

  2. Dual-scan technique for the customization of zirconia computer-aided design/computer-aided manufacturing frameworks

    PubMed Central

    Andreiuolo, Rafael Ferrone; Sabrosa, Carlos Eduardo; Dias, Katia Regina H. Cervantes

    2013-01-01

    The use of bi-layered all-ceramic crowns has continuously grown since the introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia cores. Unfortunately, despite the outstanding mechanical properties of zirconia, problems related to porcelain cracking or chipping remain. One of the reasons for this is that ceramic copings are usually milled to uniform thicknesses of 0.3-0.6 mm around the whole tooth preparation. This may not provide uniform thickness or appropriate support for the veneering porcelain. To prevent these problems, the dual-scan technique demonstrates an alternative that allows the restorative team to customize zirconia CAD/CAM frameworks with adequate porcelain thickness and support in a simple manner. PMID:24966718

  3. Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonography.

    PubMed

    Suzuki, Kenji; Yoshida, Hiroyuki; Näppi, Janne; Armato, Samuel G; Dachman, Abraham H

    2008-02-01

    One of the major challenges in computer-aided detection (CAD) of polyps in CT colonography (CTC) is the reduction of false-positive detections (FPs) without a concomitant reduction in sensitivity. A large number of FPs is likely to confound the radiologist's task of image interpretation, lower the radiologist's efficiency, and cause radiologists to lose their confidence in CAD as a useful tool. Major sources of FPs generated by CAD schemes include haustral folds, residual stool, rectal tubes, the ileocecal valve, and extra-colonic structures such as the small bowel and stomach. Our purpose in this study was to develop a method for the removal of various types of FPs in CAD of polyps while maintaining a high sensitivity. To achieve this, we developed a "mixture of expert" three-dimensional (3D) massive-training artificial neural networks (MTANNs) consisting of four 3D MTANNs that were designed to differentiate between polyps and four categories of FPs: (1) rectal tubes, (2) stool with bubbles, (3) colonic walls with haustral folds, and (4) solid stool. Each expert 3D MTANN was trained with examples from a specific non-polyp category along with typical polyps. The four expert 3D MTANNs were combined with a mixing artificial neural network (ANN) such that different types of FPs could be removed. Our database consisted of 146 CTC datasets obtained from 73 patients whose colons were prepared by standard pre-colonoscopy cleansing. Each patient was scanned in both supine and prone positions. Radiologists established the locations of polyps through the use of optical-colonoscopy reports. Fifteen patients had 28 polyps, 15 of which were 5-9 mm and 13 were 10-25 mm in size. The CTC cases were subjected to our previously reported CAD method consisting of centerline-based extraction of the colon, shape-based detection of polyp candidates, and a Bayesian-ANN-based classification of polyps. The original CAD method yielded 96.4% (27/28) by-polyp sensitivity with an average of 3

  4. Computer-aided design of flight control systems

    NASA Technical Reports Server (NTRS)

    Stengel, Robert F.; Sircar, Subrata

    1991-01-01

    A computer program is presented for facilitating the development and assessment of flight control systems, and application to a control design is discussed. The program is a computer-aided control-system design program based on direct digital synthesis of a proportional-integral-filter controller with scheduled linear-quadratic-Gaussian gains and command generator tracking of pilot inputs. The FlightCAD system concentrates on aircraft dynamics, flight-control systems, stability and performance, and has practical engineering applications.

  5. Cam Design Projects in an Advanced CAD Course for Mechanical Engineers

    ERIC Educational Resources Information Center

    Ault, H. K.

    2009-01-01

    The objective of this paper is to present applications of solid modeling aimed at modeling of complex geometries such as splines and blended surfaces in advanced CAD courses. These projects, in CAD-based Mechanical Engineering courses, are focused on the use of the CAD system to solve design problems for applications in machine design, namely the…

  6. Complete hamster CAD protein and the carbamylphosphate synthetase domain of CAD complement mammalian cell mutants defective in de novo pyrimidine biosynthesis.

    PubMed

    Musmanno, L A; Jamison, R S; Barnett, R S; Buford, E; Davidson, J N

    1992-07-01

    The mammalian CAD gene codes for a 240-kDa multifunctional protein that catalyzes the first three steps of de novo pyrimidine biosynthesis. Previously, the longest cDNA construct available was missing approximately 500 bp of coding sequence at the 5' end, thereby lacking the sequence to encode the entire carbamylphosphate synthetase (CPSase) domain. Here, a complete CAD hamster cDNA is constructed, placed into a mammalian expression vector, and transfected into hamster cells deficient in CAD. Transfectants show coordinately restored levels of all three enzyme activities and the presence of full-length CAD protein. A derivative construct of the CAD cDNA was generated that should encode only the CPSase domain. When transfected into mammalian cells, a protein was synthesized that had significant CPSase activity both in vivo and in vitro. The two constructs generated in this study will facilitate the study of CAD structure, function, and allosteric regulation. PMID:1359654

  7. Computer-Aided Design (CAD) Tools to Support the Human Factors Design Teams

    NASA Technical Reports Server (NTRS)

    Null, Cynthia H.; Jackson, Mariea D.; Perry, Trey; Quick, Jason C.; Stokes, Jack W.

    2014-01-01

    The scope of this assessment was to develop a library of basic 1-Gravity (G) human posture and motion elements used to construct complex virtual simulations of ground processing and maintenance tasks for spaceflight vehicles, including launch vehicles, crewed spacecraft, robotic spacecraft, satellites, and other payloads. The report herein describes the task, its purpose, performance, findings, NASA Engineering and Safety Center (NESC) recommendations, and conclusions in the definition and assemblage of the postures and motions database (PMD).

  8. Computer-aided detection (CAD) of hepatocellular carcinoma on multiphase CT images

    NASA Astrophysics Data System (ADS)

    Tajima, Tetsuji; Zhang, Xuejun; Kitagawa, Teruhiko; Kanematsu, Masayuki; Zhou, Xiangrong; Hara, Takeshi; Fujita, Hiroshi; Yokoyama, Ryujiro; Kondo, Hiroshi; Hoshi, Hiroaki; Nawano, Shigeru; Shinozaki, Kenji

    2007-03-01

    Primary malignant liver tumor, including hepatocellular carcinoma (HCC), caused 1.25 million deaths per year worldwide. Multiphase CT images offer clinicians important information about hepatic cancer. The presence of HCC is indicated by high-intensity regions in arterial phase images and low-intensity regions in equilibrium phase images following enhancement with contrast material. We propose an automatic method for detecting HCC based on edge detection and subtraction processing. Within a liver area segmented according to our scheme, black regions are selected by subtracting the equilibrium phase images to the corresponding registrated arterial phase images. From these black regions, the HCC candidates are extracted as the areas without edges by using Sobel and LoG edge detection filters. The false-positive (FP) candidates are eliminated by using six features extracted from the cancer and liver regions. Other FPs are further eliminated by opening processing. Finally, an expansion process is applied to acquire the 3D shape of the HCC. The cases used in this experiment were from the CT images of 44 patients, which included 44 HCCs. We extracted 97.7% (43/44) HCCs successfully by our proposed method, with an average number of 2.1 FPs per case. The result demonstrates that our edge-detection-based method is effective in locating the cancer region by using the information obtained from different phase images.

  9. Computer-aided design system with artificial intelligence for automatic dimensioning

    SciTech Connect

    Huang, R.; Juricic, D.

    1995-12-31

    This paper is concerned with the methodology applicable to automating computer drafting tasks of a Computer-Aided Drafting and Design (CADD) system. One of the main characteristics of these tasks is the need for interaction with geometric models and their features. The specific drafting task considered in this paper was dimensioning of a multiview drawing. The paper illustrates the approach used and describes the introduction of relevant knowledge base as well as implementation of an inference engine internal to the drafting system. A simple class of objects was used to illustrate in more details the methods involved. It is noted that developing this methodology may be of vital importance for further automation of the drafting and design process.

  10. Using motion planning to determine the existence of an accessible route in a CAD environment.

    PubMed

    Pan, Xiaoshan; Han, Charles S; Law, Kincho H

    2010-01-01

    We describe an algorithm based on motion-planning techniques to determine the existence of an accessible route through a facility for a wheeled mobility device. The algorithm is based on LaValle's work on rapidly exploring random trees and is enhanced to take into consideration the particularities of the accessible route domain. Specifically, the algorithm is designed to allow performance-based analysis and evaluation of a facility. Furthermore, the parameters of a wheeled mobility device can be varied without recompilation, thus allowing standards writers, facility designers, and wheeled mobility device manufacturers to vary them accordingly. The algorithm has been implemented in a computer tool that works within a computer-aided design and drafting environment. PMID:20402045

  11. Simulation tools for computer-aided design and numerical investigations of high-power gyrotrons

    NASA Astrophysics Data System (ADS)

    Damyanova, M.; Balabanova, E.; Kern, S.; Illy, S.; Sabchevski, S.; Thumm, M.; Vasileva, E.; Zhelyazkov, I.

    2012-03-01

    Modelling and simulation are essential tools for computer-aided design (CAD), analysis and optimization of high-power gyrotrons used as radiation sources for electron cyclotron resonance heating (ECRH) and current drive (ECCD) of magnetically confined plasmas in the thermonuclear reactor ITER. In this communication, we present the current status of our simulation tools and discuss their further development.

  12. 31 CFR 500.406 - Drafts under irrevocable letters of credit; documentary drafts.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... credit; documentary drafts. 500.406 Section 500.406 Money and Finance: Treasury Regulations Relating to...; documentary drafts. Section 500.201 prohibits the presentation, acceptance or payment of: (a) Drafts or other...) Documentary drafts in which any designated national has on or since the “effective date” had any interest....

  13. 76 FR 65744 - Draft Environmental Assessment and Draft Habitat Conservation Plan for Lower Colorado River...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-24

    ... Fish and Wildlife Service Draft Environmental Assessment and Draft Habitat Conservation Plan for Lower... Species Act of 1973, as amended. The applicant has completed a draft Habitat Conservation Plan (DHCP) as... Transmission Services Corporation (LCRA; applicant); and 2. LCRA has developed a draft habitat...

  14. A new model-based RSA method validated using CAD models and models from reversed engineering.

    PubMed

    Kaptein, B L; Valstar, E R; Stoel, B C; Rozing, P M; Reiber, J H C

    2003-06-01

    Roentgen stereophotogrammetric analysis (RSA) was developed to measure micromotion of an orthopaedic implant with respect to its surrounding bone. A disadvantage of conventional RSA is that it requires the implant to be marked with tantalum beads. This disadvantage can potentially be resolved with model-based RSA, whereby a 3D model of the implant is used for matching with the actual images and the assessment of position and rotation of the implant. In this study, a model-based RSA algorithm is presented and validated in phantom experiments. To investigate the influence of the accuracy of the implant models that were used for model-based RSA, we studied both computer aided design (CAD) models as well as models obtained by means of reversed engineering (RE) of the actual implant. The results demonstrate that the RE models provide more accurate results than the CAD models. If these RE models are derived from the very same implant, it is possible to achieve a maximum standard deviation of the error in the migration calculation of 0.06 mm for translations in x- and y-direction and 0.14 mm for the out of plane z-direction, respectively. For rotations about the y-axis, the standard deviation was about 0.1 degrees and for rotations about the x- and z-axis 0.05 degrees. Studies with clinical RSA-radiographs must prove that these results can also be reached in a clinical setting, making model-based RSA a possible alternative for marker-based RSA.

  15. Large scale validation of the M5L lung CAD on heterogeneous CT datasets

    SciTech Connect

    Lopez Torres, E. E-mail: cerello@to.infn.it; Fiorina, E.; Pennazio, F.; Peroni, C.; Saletta, M.; Cerello, P. E-mail: cerello@to.infn.it; Camarlinghi, N.; Fantacci, M. E.

    2015-04-15

    Purpose: M5L, a fully automated computer-aided detection (CAD) system for the detection and segmentation of lung nodules in thoracic computed tomography (CT), is presented and validated on several image datasets. Methods: M5L is the combination of two independent subsystems, based on the Channeler Ant Model as a segmentation tool [lung channeler ant model (lungCAM)] and on the voxel-based neural approach. The lungCAM was upgraded with a scan equalization module and a new procedure to recover the nodules connected to other lung structures; its classification module, which makes use of a feed-forward neural network, is based of a small number of features (13), so as to minimize the risk of lacking generalization, which could be possible given the large difference between the size of the training and testing datasets, which contain 94 and 1019 CTs, respectively. The lungCAM (standalone) and M5L (combined) performance was extensively tested on 1043 CT scans from three independent datasets, including a detailed analysis of the full Lung Image Database Consortium/Image Database Resource Initiative database, which is not yet found in literature. Results: The lungCAM and M5L performance is consistent across the databases, with a sensitivity of about 70% and 80%, respectively, at eight false positive findings per scan, despite the variable annotation criteria and acquisition and reconstruction conditions. A reduced sensitivity is found for subtle nodules and ground glass opacities (GGO) structures. A comparison with other CAD systems is also presented. Conclusions: The M5L performance on a large and heterogeneous dataset is stable and satisfactory, although the development of a dedicated module for GGOs detection could further improve it, as well as an iterative optimization of the training procedure. The main aim of the present study was accomplished: M5L results do not deteriorate when increasing the dataset size, making it a candidate for supporting radiologists on large

  16. A two-view ultrasound CAD system for spina bifida detection using Zernike features

    NASA Astrophysics Data System (ADS)

    Konur, Umut; Gürgen, Fikret; Varol, Füsun

    2011-03-01

    In this work, we address a very specific CAD (Computer Aided Detection/Diagnosis) problem and try to detect one of the relatively common birth defects - spina bifida, in the prenatal period. To do this, fetal ultrasound images are used as the input imaging modality, which is the most convenient so far. Our approach is to decide using two particular types of views of the fetal neural tube. Transcerebellar head (i.e. brain) and transverse (axial) spine images are processed to extract features which are then used to classify healthy (normal), suspicious (probably defective) and non-decidable cases. Decisions raised by two independent classifiers may be individually treated, or if desired and data related to both modalities are available, those decisions can be combined to keep matters more secure. Even more security can be attained by using more than two modalities and base the final decision on all those potential classifiers. Our current system relies on feature extraction from images for cases (for particular patients). The first step is image preprocessing and segmentation to get rid of useless image pixels and represent the input in a more compact domain, which is hopefully more representative for good classification performance. Next, a particular type of feature extraction, which uses Zernike moments computed on either B/W or gray-scale image segments, is performed. The aim here is to obtain values for indicative markers that signal the presence of spina bifida. Markers differ depending on the image modality being used. Either shape or texture information captured by moments may propose useful features. Finally, SVM is used to train classifiers to be used as decision makers. Our experimental results show that a promising CAD system can be actualized for the specific purpose. On the other hand, the performance of such a system would highly depend on the qualities of image preprocessing, segmentation, feature extraction and comprehensiveness of image data.

  17. Dental Wings CAD/CAM system precision: an internal and marginal fit sperimental analisys.

    PubMed

    Sannino, G; Gloria, F; Schiavetti, R; Ottria, L; Barlattani, A

    2009-07-01

    STATEMENT OF PROBLEM.: The CAD-CAM technology has been developed to design and manufacture prosthetic structures with constant quality characteristics; in fact procedures are codified, manageable and repeatable. PURPOSE.: The purpose of this in vitro study is to evaluate the internal and marginal gap of zirconia casts made with a new CAD-CAM systematic that use Dental Wings laser scanner and Yenamak milling machine. MATERIAL AND METHODS.: 6 analogs of solid abutments of Straumann implants were used, fixed in plexiglass bases. The samples were scanned by Dental Wings laser; the file obtained by scanning of each probe was sent to the Yenamak D40 milling machine, then the casts were sintered in Protherm furnace. Then 6 samples were cemented with resin luting agent capsules (Relyx Unicem, 3M ESPE). The samples were incorporated in transparent epoxy resin. After resin hardening, the cylinders obtained were cut with a microtomes. These slices thus obtained were then polished with a Polisher sander with alumina dust decreasing grain. Each section was observed and photographed in reflected light with the aid of an optic microscope type, first at low magnification and then at higher magnification. RESULTS.: The overall average fitting of copings on the abutments was 32,87 μ. No differences were found in marginal fit on buccal and lingual sides, it was easily predictable because of the standard form of the used stumps. The recorded values for the marginal fit were lower than those of axial walls. The accuracy of adaptation was always achieved within the limits of clinical acceptability. CONCLUSIONS.: Within the limitations of this study, the system evaluated represents a valuable alternative to conventional prosthetic rehabilitation techniques.

  18. The genesis of the AIDS policy and AIDS Space in Brazil (1981-1989)

    PubMed Central

    de Barros, Sandra Garrido; Vieira-da-Silva, Ligia Maria

    2016-01-01

    ABSTRACT OBJECTIVE To analyze the genesis of the policy for controlling AIDS in Brazil. METHODS Socio-historical study (1981-1989), based on Bordieu’s genetic sociology, by document analysis, bibliographical review, and in-depth interviews. It consisted of a connection between the analysis of the paths of 33 agents involved in the creation of a social space focusing on AIDS-related issues and the historical possibility conditions of the drafting of a specific policy. RESULTS AIDS Space is a gathering point for the paths of agents from several social fields (medical, scientific, political, and bureaucratic fields). A specific space for relationships, which enabled the drafting of a policy for controlling the AIDS epidemic, but also a place where the authority to talk about the meaning of the disease, the methods to prevent and treat it was under dispute. The analysis showed how the various structures (democratic administrations in Sao Paulo and at the national level, with public health officers taking important positions) and the lack of a specific therapy contributed to social agents of different ranks and backgrounds to initially set prevention as a priority. CONCLUSIONS The rise of the sanitary movement, the organization of SUS, and the dominance of the medical field at the AIDS Space contributed to foster treatment as a part of the measures to control the epidemic. These conditions allowed drafting a policy based on the integrality of care, by linking prevention and treatment in the following decade, with important participation from state bureaucracy and researchers. PMID:27463255

  19. Teaching Legislative Drafting: A Simulation Approach.

    ERIC Educational Resources Information Center

    Stern, Barry Jeffrey

    1988-01-01

    An approach to teaching legislative drafting uses limited traditional classroom instruction and intensive exposure to the process of legislative drafting through a classroom simulation in which students revise the Massachusetts criminal code. (MSE)

  20. A Model Based Framework for Semantic Interpretation of Architectural Construction Drawings

    ERIC Educational Resources Information Center

    Babalola, Olubi Oluyomi

    2011-01-01

    The study addresses the automated translation of architectural drawings from 2D Computer Aided Drafting (CAD) data into a Building Information Model (BIM), with emphasis on the nature, possible role, and limitations of a drafting language Knowledge Representation (KR) on the problem and process. The central idea is that CAD to BIM translation is a…

  1. Diagnostic Accuracy of Digital Screening Mammography with and without Computer-aided Detection

    PubMed Central

    Lehman, Constance D.; Wellman, Robert D.; Buist, Diana S.M.; Kerlikowske, Karla; Tosteson, Anna N. A.; Miglioretti, Diana L.

    2016-01-01

    Importance After the Food and Drug Administration (FDA) approved computer-aided detection (CAD) for mammography in 1998, and Centers for Medicare and Medicaid Services (CMS) provided increased payment in 2002, CAD technology disseminated rapidly. Despite sparse evidence that CAD improves accuracy of mammographic interpretations, and costs over $400 million dollars a year, CAD is currently used for the majority of screening mammograms in the U.S. Objective To measure performance of digital screening mammography with and without computer-aided detection in U.S. community practice. Design, Setting and Participants We compared the accuracy of digital screening mammography interpreted with (N=495,818) vs. without (N=129,807) computer-aided detection from 2003 through 2009 in 323,973 women. Mammograms were interpreted by 271 radiologists from 66 facilities in the Breast Cancer Surveillance Consortium. Linkage with tumor registries identified 3,159 breast cancers in 323,973 women within one year of the screening. Main Outcomes and Measures Mammography performance (sensitivity, specificity, and screen detected and interval cancers per 1,000 women) was modeled using logistic regression with radiologist-specific random effects to account for correlation among examinations interpreted by the same radiologist, adjusting for patient age, race/ethnicity, time since prior mammogram, exam year, and registry. Conditional logistic regression was used to compare performance among 107 radiologists who interpreted mammograms both with and without computer-aided detection. Results Screening performance was not improved with computer-aided detection on any metric assessed. Mammography sensitivity was 85.3% (95% confidence interval [CI]=83.6–86.9) with and 87.3% (95% CI 84.5–89.7) without computer-aided detection. Specificity was 91.6% (95% CI=91.0–92.2) with and 91.4% (95% CI=90.6–92.0) without computer-aided detection. There was no difference in cancer detection rate (4

  2. Computer aided diagnosis of diabetic peripheral neuropathy

    NASA Astrophysics Data System (ADS)

    Chekh, Viktor; Soliz, Peter; McGrew, Elizabeth; Barriga, Simon; Burge, Mark; Luan, Shuang

    2014-03-01

    Diabetic peripheral neuropathy (DPN) refers to the nerve damage that can occur in diabetes patients. It most often affects the extremities, such as the feet, and can lead to peripheral vascular disease, deformity, infection, ulceration, and even amputation. The key to managing diabetic foot is prevention and early detection. Unfortunately, current existing diagnostic techniques are mostly based on patient sensations and exhibit significant inter- and intra-observer differences. We have developed a computer aided diagnostic (CAD) system for diabetic peripheral neuropathy. The thermal response of the feet of diabetic patients following cold stimulus is captured using an infrared camera. The plantar foot in the images from a thermal video are segmented and registered for tracking points or specific regions. The temperature recovery of each point on the plantar foot is extracted using our bio-thermal model and analyzed. The regions that exhibit abnormal ability to recover are automatically identified to aid the physicians to recognize problematic areas. The key to our CAD system is the segmentation of infrared video. The main challenges for segmenting infrared video compared to normal digital video are (1) as the foot warms up, it also warms up the surrounding, creating an ever changing contrast; and (2) there may be significant motion during imaging. To overcome this, a hybrid segmentation algorithm was developed based on a number of techniques such as continuous max-flow, model based segmentation, shape preservation, convex hull, and temperature normalization. Verifications of the automatic segmentation and registration using manual segmentation and markers show good agreement.

  3. HIV/AIDS Basics

    MedlinePlus

    ... Enter ZIP code or city Follow Act Against AIDS Act Against AIDS @talkHIV Act Against AIDS Get Email Updates on AAA Anonymous Feedback HIV/AIDS Media Infographics Syndicated Content Podcasts Slide Sets HIV/ ...

  4. Impact of CAD-deficiency in flax on biogas production.

    PubMed

    Wróbel-Kwiatkowska, Magdalena; Jabłoński, Sławomir; Szperlik, Jakub; Dymińska, Lucyna; Łukaszewicz, Marcin; Rymowicz, Waldemar; Hanuza, Jerzy; Szopa, Jan

    2015-12-01

    Global warming and the reduction in our fossil fuel reservoir have forced humanity to look for new means of energy production. Agricultural waste remains a large source for biofuel and bioenergy production. Flax shives are a waste product obtained during the processing of flax fibers. We investigated the possibility of using low-lignin flax shives for biogas production, specifically by assessing the impact of CAD deficiency on the biochemical and structural properties of shives. The study used genetically modified flax plants with a silenced CAD gene, which encodes the key enzyme for lignin synthesis. Reducing the lignin content modified cellulose crystallinity, improved flax shive fermentation and optimized biogas production. Chemical pretreatment of the shive biomass further increased biogas production efficiency.

  5. Impact of CAD-deficiency in flax on biogas production.

    PubMed

    Wróbel-Kwiatkowska, Magdalena; Jabłoński, Sławomir; Szperlik, Jakub; Dymińska, Lucyna; Łukaszewicz, Marcin; Rymowicz, Waldemar; Hanuza, Jerzy; Szopa, Jan

    2015-12-01

    Global warming and the reduction in our fossil fuel reservoir have forced humanity to look for new means of energy production. Agricultural waste remains a large source for biofuel and bioenergy production. Flax shives are a waste product obtained during the processing of flax fibers. We investigated the possibility of using low-lignin flax shives for biogas production, specifically by assessing the impact of CAD deficiency on the biochemical and structural properties of shives. The study used genetically modified flax plants with a silenced CAD gene, which encodes the key enzyme for lignin synthesis. Reducing the lignin content modified cellulose crystallinity, improved flax shive fermentation and optimized biogas production. Chemical pretreatment of the shive biomass further increased biogas production efficiency. PMID:26178244

  6. General KBE model with inheritance and multi CAD support

    NASA Astrophysics Data System (ADS)

    Tiuca, T. L.; Rusu, C.; Noveanu, S.; Mandru, D.

    2016-08-01

    Knowledge-Based Engineering (KBE) is a research field that studies methodologies and technologies for capture and re-use engineering knowledge. The primary objective of KBE is to reduce time and cost of product research processes and/or product development, which is primarily achieved through automation of repetitive design tasks while capturing, retaining and re-using engineering knowledge. Every CAD System includes KBE Tools. The power of these tools is incremented by the use of external high level programming language. The model presented in this paper has the aim to reduce times and costs of particular KBE Models development, by programming inheritance concepts and also the multi CAD Support. The model is implemented through a C# application that is also presented.

  7. Three dimensional CAD model of the Ignitor machine

    NASA Astrophysics Data System (ADS)

    Orlandi, S.; Zanaboni, P.; Macco, A.; Sioli, V.; Risso, E.

    1998-11-01

    defind The final, global product of all the structural and thermomechanical design activities is a complete three dimensional CAD (AutoCAD and Intergraph Design Review) model of the IGNITOR machine. With this powerful tool, any interface, modification, or upgrading of the machine design is managed as an integrated part of the general effort aimed at the construction of the Ignitor facility. ind The activities that are underway, to complete the design of the core of the experiment and that will be described, concern the following: ind - the cryogenic cooling system, ind - the radial press, the center post, the mechanical supports (legs) of the entire machine, ind - the inner mechanical supports of major components such as the plasma chamber and the outer poloidal field coils.

  8. 7 CFR 1488.13 - CCC drafts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Bank of New York discount rate from and including the date payment was originally made to CCC but not...) Bank Obligations and Repayment § 1488.13 CCC drafts. CCC will draw one draft for each payment due under bank obligations. If any portion of a CCC draft is dishonored, the U.S. bank or branch bank...

  9. 7 CFR 1488.13 - CCC drafts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Bank of New York discount rate from and including the date payment was originally made to CCC but not...) Bank Obligations and Repayment § 1488.13 CCC drafts. CCC will draw one draft for each payment due under bank obligations. If any portion of a CCC draft is dishonored, the U.S. bank or branch bank...

  10. Mechnical Drawing/Drafting Curriculum Guide.

    ERIC Educational Resources Information Center

    Gregory, Margaret R.; Benson, Robert T.

    This curriculum guide consists of materials for teaching a course in mechanical drawing and drafting. Addressed in the individual units of the guide are the following topics: the nature and scope of drawing and drafting, visualization and spatial relationships, drafting tools and materials, linework, freehand lettering, geometric construction,…

  11. 32 CFR 989.19 - Draft EIS.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... proponent in preparation of a preliminary draft EIS (PDEIS) (40 CFR 1502.9) based on the scope of issues... recommended in the CEQ regulations (40 CFR 1502.10 and 1502.11). The CEQ regulations indicate that EISs... review of draft EIS (40 CFR 1502.19 and 1506.6): (1) The public comment period for the draft EIS is...

  12. 32 CFR 989.19 - Draft EIS.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... proponent in preparation of a preliminary draft EIS (PDEIS) (40 CFR 1502.9) based on the scope of issues... recommended in the CEQ regulations (40 CFR 1502.10 and 1502.11). The CEQ regulations indicate that EISs... review of draft EIS (40 CFR 1502.19 and 1506.6): (1) The public comment period for the draft EIS is...

  13. 32 CFR 989.19 - Draft EIS.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... proponent in preparation of a preliminary draft EIS (PDEIS) (40 CFR 1502.9) based on the scope of issues... recommended in the CEQ regulations (40 CFR 1502.10 and 1502.11). The CEQ regulations indicate that EISs... review of draft EIS (40 CFR 1502.19 and 1506.6): (1) The public comment period for the draft EIS is...

  14. 32 CFR 989.19 - Draft EIS.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... proponent in preparation of a preliminary draft EIS (PDEIS) (40 CFR 1502.9) based on the scope of issues... recommended in the CEQ regulations (40 CFR 1502.10 and 1502.11). The CEQ regulations indicate that EISs... review of draft EIS (40 CFR 1502.19 and 1506.6): (1) The public comment period for the draft EIS is...

  15. A comparative analysis of 2D and 3D CAD for calcifications in digital breast tomosynthesis

    NASA Astrophysics Data System (ADS)

    Acciavatti, Raymond J.; Ray, Shonket; Keller, Brad M.; Maidment, Andrew D. A.; Conant, Emily F.

    2015-03-01

    Many medical centers offer digital breast tomosynthesis (DBT) and 2D digital mammography acquired under the same compression (i.e., "Combo" examination) for screening. This paper compares a conventional 2D CAD algorithm (Hologic® ImageChecker® CAD v9.4) for calcification detection against a prototype 3D algorithm (Hologic® ImageChecker® 3D Calc CAD v1.0). Due to the newness of DBT, the development of this 3D CAD algorithm is ongoing, and it is currently not FDA-approved in the United States. For this study, DBT screening cases with suspicious calcifications were identified retrospectively at the University of Pennsylvania. An expert radiologist (E.F.C.) reviewed images with both 2D and DBT CAD marks, and compared the marks to biopsy results. Control cases with one-year negative follow-up were also studied; these cases either possess clearly benign calcifications or lacked calcifications. To allow the user to alter the sensitivity for cancer detection, an operating point is assigned to each CAD mark. As expected from conventional 2D CAD, increasing the operating point in 3D CAD increases sensitivity and reduces specificity. Additionally, we showed that some cancers are occult to 2D CAD at all operating points. By contrast, 3D CAD allows for detection of some cancers that are missed on 2D CAD. We also demonstrated that some non-cancerous CAD marks in 3D are not present at analogous locations in the 2D image. Hence, there are additional marks when using both 2D and 3D CAD in combination, leading to lower specificity than with conventional 2D CAD alone.

  16. CAD integration: opening up new optical design possibilities; Technical Digest

    NASA Astrophysics Data System (ADS)

    Haumonte, Jean-Baptiste; Venturino, Jean-Claude

    2005-05-01

    The development of optical design and analysis tools in a CAD software can help to optimise the design, size and performance of tomorrow's consumer produtcs. While optics was still held back by software limitations, CAD programs were moving forward in leaps and bounds, improving manufacturing technologies and making it possible to design and produce highly innovative and sophisticated products. The problem was that in the past, 'traditional' optical design programs were only able to simulate spherical and aspherical lenses, meaning that the optical designers were limited to designing systems which were a series of imperfect lenses, each one correcting the last. That is why OPTIS has created the first optical design program to be fully integrated into a CAD program. The technology is available from OPTIS in an integrated SOLIDWORKS or CATIA V5 version. Users of this software can reduce the number of lenses needed in a system. Designers will now have access to complex surfaces such as NURBS meaning they will now be able to define free shape progressive lenses and even improve on optical performances using fewer lenses. This revolutionary technology will allow mechanical designers to work on optical systems and to shre information with optical designers for the first time. Previously not possible in a CAD program you may now determine all the optical performances of any optical system, providing first order and third order performances, sequential and non-sequential ray-tracing, wavefront surfaces, point spread function, MTF, spot-diagram, using real optical surfaces and guaranteeing the mechanical precision necessary for an optical system.

  17. Integrated CAD/CAM: Problems, prognosis, and role of IPAD

    NASA Technical Reports Server (NTRS)

    Nilson, E. N.

    1980-01-01

    Major technology problems impede the development and evolution of totally integrated interactive CAD/CAM systems. IPAD is playing an important role in the identification of these problems and is contributing significantly to their solution. It is the purpose of this presentation to examine some of these issues, look at the prognosis of obtaining effective solutions, and point up some of the past and expected contributions of IPAD to this technology.

  18. Application of fusion algorithms for computer aided detection and classification of bottom mines to synthetic aperture sonar test data

    NASA Astrophysics Data System (ADS)

    Ciany, Charles M.; Zurawski, William C.

    2006-05-01

    Over the past several years, Raytheon Company has adapted its Computer Aided Detection/Computer-Aided Classification (CAD/CAC) algorithm to process side-scan sonar imagery taken in both the Very Shallow Water (VSW) and Shallow Water (SW) operating environments. This paper describes the further adaptation of this CAD/CAC algorithm to process Synthetic Aperture Sonar (SAS) image data taken by an Autonomous Underwater Vehicle (AUV). The tuning of the CAD/CAC algorithm for the vehicle's sonar is described, the resulting classifier performance is presented, and the fusion of the classifier outputs with those of another CAD/CAC processor is evaluated. The fusion algorithm accepts the classification confidence levels and associated contact locations from the different CAD/CAC algorithms, clusters the contacts based on the distance between their locations, and then declares a valid target when a clustered contact passes a prescribed fusion criterion. Three different fusion criteria are evaluated: the first based on thresholding the sum of the confidence factors for the clustered contacts, the second based on simple binary combinations of the multiple CAD/CAC processor outputs, and the third based on the Fisher Discriminant. The resulting performance of the three fusion algorithms is compared, and the overall performance benefit of a significant reduction of false alarms at high correct classification probabilities is quantified.

  19. Numerical Simulation of the Francis Turbine and CAD used to Optimized the Runner Design (2nd).

    NASA Astrophysics Data System (ADS)

    Sutikno, Priyono

    2010-06-01

    Hydro Power is the most important renewable energy source on earth. The water is free of charge and with the generation of electric energy in a Hydroelectric Power station the production of green house gases (mainly CO2) is negligible. Hydro Power Generation Stations are long term installations and can be used for 50 years and more, care must be taken to guarantee a smooth and safe operation over the years. Maintenance is necessary and critical parts of the machines have to be replaced if necessary. Within modern engineering the numerical flow simulation plays an important role in order to optimize the hydraulic turbine in conjunction with connected components of the plant. Especially for rehabilitation and upgrading existing Power Plants important point of concern are to predict the power output of turbine, to achieve maximum hydraulic efficiency, to avoid or to minimize cavitations, to avoid or to minimized vibrations in whole range operation. Flow simulation can help to solve operational problems and to optimize the turbo machinery for hydro electric generating stations or their component through, intuitive optimization, mathematical optimization, parametric design, the reduction of cavitations through design, prediction of draft tube vortex, trouble shooting by using the simulation. The classic design through graphic-analytical method is cumbersome and can't give in evidence the positive or negative aspects of the designing options. So it was obvious to have imposed as necessity the classical design methods to an adequate design method using the CAD software. There are many option chose during design calculus in a specific step of designing may be verified in ensemble and detail form a point of view. The final graphic post processing would be realized only for the optimal solution, through a 3 D representation of the runner as a whole for the final approval geometric shape. In this article it was investigated the redesign of the hydraulic turbine's runner

  20. AutoBioCAD: full biodesign automation of genetic circuits.

    PubMed

    Rodrigo, Guillermo; Jaramillo, Alfonso

    2013-05-17

    Synthetic regulatory networks with prescribed functions are engineered by assembling a reduced set of functional elements. We could also assemble them computationally if the mathematical models of those functional elements were predictive enough in different genetic contexts. Only after achieving this will we have libraries of models of biological parts able to provide predictive dynamical behaviors for most circuits constructed with them. We thus need tools that can automatically explore different genetic contexts, in addition to being able to use such libraries to design novel circuits with targeted dynamics. We have implemented a new tool, AutoBioCAD, aimed at the automated design of gene regulatory circuits. AutoBioCAD loads a library of models of genetic elements and implements evolutionary design strategies to produce (i) nucleotide sequences encoding circuits with targeted dynamics that can then be tested experimentally and (ii) circuit models for testing regulation principles in natural systems, providing a new tool for synthetic biology. AutoBioCAD can be used to model and design genetic circuits with dynamic behavior, thanks to the incorporation of stochastic effects, robustness, qualitative dynamics, multiobjective optimization, or degenerate nucleotide sequences, all facilitating the link with biological part/circuit engineering.

  1. Use of Existing CAD Models for Radiation Shielding Analysis

    NASA Technical Reports Server (NTRS)

    Lee, K. T.; Barzilla, J. E.; Wilson, P.; Davis, A.; Zachman, J.

    2015-01-01

    The utility of a radiation exposure analysis depends not only on the accuracy of the underlying particle transport code, but also on the accuracy of the geometric representations of both the vehicle used as radiation shielding mass and the phantom representation of the human form. The current NASA/Space Radiation Analysis Group (SRAG) process to determine crew radiation exposure in a vehicle design incorporates both output from an analytic High Z and Energy Particle Transport (HZETRN) code and the properties (i.e., material thicknesses) of a previously processed drawing. This geometry pre-process can be time-consuming, and the results are less accurate than those determined using a Monte Carlo-based particle transport code. The current work aims to improve this process. Although several Monte Carlo programs (FLUKA, Geant4) are readily available, most use an internal geometry engine. The lack of an interface with the standard CAD formats used by the vehicle designers limits the ability of the user to communicate complex geometries. Translation of native CAD drawings into a format readable by these transport programs is time consuming and prone to error. The Direct Accelerated Geometry -United (DAGU) project is intended to provide an interface between the native vehicle or phantom CAD geometry and multiple particle transport codes to minimize problem setup, computing time and analysis error.

  2. Ovulation leads women to perceive sexy cads as good dads.

    PubMed

    Durante, Kristina M; Griskevicius, Vladas; Simpson, Jeffry A; Cantú, Stephanie M; Li, Norman P

    2012-08-01

    Why do some women pursue relationships with men who are attractive, dominant, and charming but who do not want to be in relationships--the prototypical sexy cad? Previous research shows that women have an increased desire for such men when they are ovulating, but it is unclear why ovulating women would think it is wise to pursue men who may be unfaithful and could desert them. Using both college-age and community-based samples, in 3 studies we show that ovulating women perceive charismatic and physically attractive men, but not reliable and nice men, as more committed partners and more devoted future fathers. Ovulating women perceive that sexy cads would be good fathers to their own children but not to the children of other women. This ovulatory-induced perceptual shift is driven by women who experienced early onset of puberty. Taken together, the current research identifies a novel proximate reason why ovulating women pursue relationships with sexy cads, complementing existing research that identifies the ultimate, evolutionary reasons for this behavior.

  3. Ovulation leads women to perceive sexy cads as good dads.

    PubMed

    Durante, Kristina M; Griskevicius, Vladas; Simpson, Jeffry A; Cantú, Stephanie M; Li, Norman P

    2012-08-01

    Why do some women pursue relationships with men who are attractive, dominant, and charming but who do not want to be in relationships--the prototypical sexy cad? Previous research shows that women have an increased desire for such men when they are ovulating, but it is unclear why ovulating women would think it is wise to pursue men who may be unfaithful and could desert them. Using both college-age and community-based samples, in 3 studies we show that ovulating women perceive charismatic and physically attractive men, but not reliable and nice men, as more committed partners and more devoted future fathers. Ovulating women perceive that sexy cads would be good fathers to their own children but not to the children of other women. This ovulatory-induced perceptual shift is driven by women who experienced early onset of puberty. Taken together, the current research identifies a novel proximate reason why ovulating women pursue relationships with sexy cads, complementing existing research that identifies the ultimate, evolutionary reasons for this behavior. PMID:22582900

  4. Use of Technology Solutions to Improve CAD Instruction

    ERIC Educational Resources Information Center

    Ault, Holly K.; Fraser, Alister

    2012-01-01

    Engineering Graphics curricula have changed dramatically in the past three decades. In the past, students in nearly all engineering disciplines were instructed in manual drafting and descriptive geometry. Students spent many hours "on the board", and this training enhanced the students' graphics communication, design and visualization skills…

  5. Improved mammographic interpretation of masses using computer-aided diagnosis.

    PubMed

    Leichter, I; Fields, S; Nirel, R; Bamberger, P; Novak, B; Lederman, R; Buchbinder, S

    2000-01-01

    The aim of this study was to evaluate the effectiveness of computerized image enhancement, to investigate criteria for discriminating benign from malignant mammographic findings by computer-aided diagnosis (CAD), and to test the role of quantitative analysis in improving the accuracy of interpretation of mass lesions. Forty sequential mammographically detected mass lesions referred for biopsy were digitized at high resolution for computerized evaluation. A prototype CAD system which included image enhancement algorithms was used for a better visualization of the lesions. Quantitative features which characterize the spiculation were automatically extracted by the CAD system for a user-defined region of interest (ROI). Reference ranges for malignant and benign cases were acquired from data generated by 214 known retrospective cases. The extracted parameters together with the reference ranges were presented to the radiologist for the analysis of 40 prospective cases. A pattern recognition scheme based on discriminant analysis was trained on the 214 retrospective cases, and applied to the prospective cases. Accuracy of interpretation with and without the CAD system, as well as the performance of the pattern recognition scheme, were analyzed using receiver operating characteristics (ROC) curves. A significant difference (p < 0.005) was found between features extracted by the CAD system for benign and malignant cases. Specificity of the CAD-assisted diagnosis improved significantly (p < 0.02) from 14 % for the conventional assessment to 50 %, and the positive predictive value increased from 0.47 to 0.62 (p < 0.04). The area under the ROC curve (A(z)) increased significantly (p < 0. 001) from 0.66 for the conventional assessment to 0.81 for the CAD-assisted analysis. The A(z) for the results of the pattern recognition scheme was higher (0.95). The results indicate that there is an improved accuracy of diagnosis with the use of the mammographic CAD system above that of the

  6. Dynamic MRI-based computer aided diagnostic systems for early detection of kidney transplant rejection: A survey

    NASA Astrophysics Data System (ADS)

    Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman

    2013-10-01

    Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.

  7. The interplay of attention economics and computer-aided detection marks in screening mammography

    NASA Astrophysics Data System (ADS)

    Schwartz, Tayler M.; Sridharan, Radhika; Wei, Wei; Lukyanchenko, Olga; Geiser, William; Whitman, Gary J.; Haygood, Tamara Miner

    2016-03-01

    Introduction: According to attention economists, overabundant information leads to decreased attention for individual pieces of information. Computer-aided detection (CAD) alerts radiologists to findings potentially associated with breast cancer but is notorious for creating an abundance of false-positive marks. We suspected that increased CAD marks do not lengthen mammogram interpretation time, as radiologists will selectively disregard these marks when present in larger numbers. We explore the relevance of attention economics in mammography by examining how the number of CAD marks affects interpretation time. Methods: We performed a retrospective review of bilateral digital screening mammograms obtained between January 1, 2011 and February 28, 2014, using only weekend interpretations to decrease distractions and the likelihood of trainee participation. We stratified data according to reader and used ANOVA to assess the relationship between number of CAD marks and interpretation time. Results: Ten radiologists, with median experience after residency of 12.5 years (range 6 to 24,) interpreted 1849 mammograms. When accounting for number of images, Breast Imaging Reporting and Data System category, and breast density, increasing numbers of CAD marks was correlated with longer interpretation time only for the three radiologists with the fewest years of experience (median 7 years.) Conclusion: For the 7 most experienced readers, increasing CAD marks did not lengthen interpretation time. We surmise that as CAD marks increase, the attention given to individual marks decreases. Experienced radiologists may rapidly dismiss larger numbers of CAD marks as false-positive, having learned that devoting extra attention to such marks does not improve clinical detection.

  8. Caught in the Draft

    NASA Astrophysics Data System (ADS)

    Edge, Ron

    2007-09-01

    We've all seen (in movies, newscasts, or perhaps in person) the violent effect of the downwash that occurs when a helicopter hovers over the ground. Leaves, grass, and debris are dramatically blown about. We've also sat in front of circulating room fans and felt a large draft, whereas there seems to be very little air movement behind the fan. The cause of this is a delightful manifestation of Bernoulli's principle. The fan blades, or helicopter rotor blades, produce a pressure differential as air passes through them—let us say p1 before and p2 after, as shown in Fig. 1, with p2 greater than p1. If p0 is the ambient pressure, Bernoulli's equation gives p0=p1 +(1/2)ρv12, where v1 is the velocity of the air entering the fan. Continuity requires that v2 leaving the fan must equal v1 entering the fan for an incompressible fluid, approximately true here (Av1 = Av2, where A is the area swept out by the blades, the "rotor disk area"). However, some distance below the rotor (or in front of the fan) the velocity is vd (vdowndraft in the figure) and the pressure again p0, so Bernoulli gives us p2 + (1/2)ρv22 = (p1 + Δp) + (1/2) ρv12 = [p1 + (p2 - p1)] +(1/2) ρv12 = p2 + (1/2)ρv12 = p0 + (1/2) ρvd2.

  9. Computer-aided detection system for clustered microcalcifications: comparison of performance on full-field digital mammograms and digitized screen-film mammograms

    NASA Astrophysics Data System (ADS)

    Ge, Jun; Hadjiiski, Lubomir M.; Sahiner, Berkman; Wei, Jun; Helvie, Mark A.; Zhou, Chuan; Chan, Heang-Ping

    2007-02-01

    We have developed a computer-aided detection (CAD) system to detect clustered microcalcifications automatically on full-field digital mammograms (FFDMs) and a CAD system for screen-film mammograms (SFMs). The two systems used the same computer vision algorithms but their false positive (FP) classifiers were trained separately with sample images of each modality. In this study, we compared the performance of the CAD systems for detection of clustered microcalcifications on pairs of FFDM and SFM obtained from the same patient. For case-based performance evaluation, the FFDM CAD system achieved detection sensitivities of 70%, 80% and 90% at an average FP cluster rate of 0.07, 0.16 and 0.63 per image, compared with an average FP cluster rate of 0.15, 0.38 and 2.02 per image for the SFM CAD system. The difference was statistically significant with the alternative free-response receiver operating characteristic (AFROC) analysis. When evaluated on data sets negative for microcalcification clusters, the average FP cluster rates of the FFDM CAD system were 0.04, 0.11 and 0.33 per image at detection sensitivity level of 70%, 80% and 90% compared with an average FP cluster rate of 0.08, 0.14 and 0.50 per image for the SFM CAD system. When evaluated for malignant cases only, the difference of the performance of the two CAD systems was not statistically significant with AFROC analysis.

  10. Cluster: Drafting. Course: Basic Technical Drafting. Research Project.

    ERIC Educational Resources Information Center

    Sanford - Lee County Schools, NC.

    The set of six units is designed for use with an instructor in basic technical drafting and is also keyed to other texts. Each unit contains several task packages specifying prerequisites, rationale for learning, objectives, learning activities to be supervised by the instructor, and learning practice. The units cover: pictorial drawing; screw…

  11. Molecular cloning, functional analysis of three cinnamyl alcohol dehydrogenase (CAD) genes in the leaves of tea plant, Camellia sinensis.

    PubMed

    Deng, Wei-Wei; Zhang, Ming; Wu, Jian-Qiang; Jiang, Zheng-Zhong; Tang, Lei; Li, Ye-Yun; Wei, Chao-Ling; Jiang, Chang-Jun; Wan, Xiao-Chun

    2013-02-15

    Cinnamyl alcohol dehydrogenase (CAD; EC 1.1.1.195) is considered to be a key enzyme in lignin biosynthesis, but little was known about CADs in tea plants (Camellia sinensis). A full-length cDNA sequence (CsCAD2) was isolated by suppressive subtractive hybridization (SSH) in Ectropis oblique feeding-induced tea plants, and another two full-length cDNA sequences (CsCAD1 and CsCAD3) were obtained from a transcriptome obtained by deep sequencing. However, they showed only 20-54% identities. Phylogenetic analysis revealed that they belonged to three different families. DNA gel blotting analysis revealed that two copies of CsCAD1 and CsCAD2 genes existed in tea genome, but CsCAD3 likely had only one copy. Recombinant proteins of these CsCADs were produced in Escherichia coli. The activity of purified recombinant CsCAD2 protein was up to 0.43 μmol min(-1) mg(-1). However, the other two recombinant proteins had lower activities, probably due to incomplete refolding. qRT-PCR analysis indicated that while CsCAD3 was strongly up-regulated in tea plants after E. oblique attack and mechanical damage, CsCAD1 and CsCAD2 showed only moderate or no changes in transcript levels. Treatment of defence-related hormones methyl jasmonate (MeJA) and salicylic acid (SA) elevated the expression of CsCAD1 and CsCAD2, but decreased the transcript abundance of CsCAD3. The transcript levels of CsCAD2 did not change after applying abscisic acid (ABA), whereas CsCAD1 and CsCAD3 were induced. These results suggested that these three CsCAD genes in tea plants may play a role in defense against insects and pathogens and adaptation to abiotic stresses and these genes likely have divergant functions.

  12. CAD/CAM technologies in the surgical and prosthetic treatment of the edentulous patient with biomymetic individualized approach

    PubMed Central

    POZZI, A.; GARGARI, M.; BARLATTANI, A.

    2008-01-01

    SUMMARY Background: The advent of modern endosseous implant design and improved surface technology has allowed the development of new restorative techniques that decrease patient’s total treatment time. Utilizing the latest scanning, CAD/CAM and manufacturing technolgies we are able to manufacture individualized dental restoration with high accuracy and a perfect precision of fit. Materials and methods: This report describes the rehabilitation of a completely edentulous patient utilizing a CT-based implant planning with computer-assisted surgical design, simultaneous CAD/CAM fabrication of a surgical template, a flapless surgical placement of the implants, and a prefabricated fixed complete denture for an immediately loaded restoration according to Nobel Biocare’s Teeth-in-an-Hour™ (Nobel Biocare Goteborg, Sweden) protocol. This systematic approach to full mouth rehabilitation reduces the time necessary for an edentulous patient to go from severely atrophic alveolar support to implant retained prosthetic restoration. These aspects of minimally invasive and simplified surgery, along with reducing the treatment time and postsurgical discomfort, are beneficial to the patient, and allowing for rehabilitation with the same level of success as in flap surgery. Conclusion: The Teeth-in-an-Hour protocol is a unique solution made possible by the Procera System. With the aid of the CT scans and a virtual planning software, a custom fabricated precision drill guide and a pre-manufactured prosthesis can be made before surgery. The execution of implant placement is performed with a flapless procedure that results in minimal surgical intervention. This results in a short and non-traumatic surgery with a minimum of postoperative complications, allowing the patient to leave the chair with a fixed prosthesis. Utilizing the latest scanning, CAD/CAM and manufacturing technologies the dental team is able to develop individualized zirconia full arch framework with high accuracy

  13. Computer-aided forensic facial reconstruction.

    PubMed

    Evenhouse, R; Rasmussen, M; Sadler, L

    1992-01-01

    The reconstruction of facial features on the human skull for identification purposes has, in the past, utilized either two-dimensional drafting or three-dimensional sculpting techniques. We have developed two- and three-dimensional computer-aided routines to minimize errors introduced by limits of artistic ability or by inconsistencies in the application of techniques. These routines allow generalized facial features to be manipulated to conform to the size and shape of a specific skull. Subtle alterations of the surface form, texture, and color, based on age, sex, and race, enhance the individuality of the generated facial form. PMID:1624477

  14. Computer Aided Design of Computer Generated Holograms for electron beam fabrication

    NASA Technical Reports Server (NTRS)

    Urquhart, Kristopher S.; Lee, Sing H.; Guest, Clark C.; Feldman, Michael R.; Farhoosh, Hamid

    1989-01-01

    Computer Aided Design (CAD) systems that have been developed for electrical and mechanical design tasks are also effective tools for the process of designing Computer Generated Holograms (CGHs), particularly when these holograms are to be fabricated using electron beam lithography. CAD workstations provide efficient and convenient means of computing, storing, displaying, and preparing for fabrication many of the features that are common to CGH designs. Experience gained in the process of designing CGHs with various types of encoding methods is presented. Suggestions are made so that future workstations may further accommodate the CGH design process.

  15. Manufacturing Aids

    NASA Technical Reports Server (NTRS)

    1989-01-01

    During a research program, MMTC/Textron invented a computer-aided automatic robotic system for spraying hot plasma onto a turbine blade. The need to control the thickness of the plasma deposit led to the development of advanced optical gaging techniques to monitor and control plasma spray build-up on blade surfaces. The techniques led to computerized optical gages for inspecting aircraft, industrial turbine blades, etc. MMTC offers 10 standard commercial robotic gages. The system also generates two dimensional profiles for assessing status and specifying repairs to the electromechanical cathodes used to make the parts. It is capable of accuracies to a ten-thousandth of an inch. An expanded product line is currently marketed. The gages offer multiple improvements in quality control and significant savings.

  16. Draft Genome Sequence of Chlamydia trachomatis Strain 54, Isolated from the Urogenital Tract of a Male in Japan

    PubMed Central

    Yamazaki, Tomohiro; Matsuo, Junji; Kikuchi, Momoka; Miyamoto, Kentaro; Oka, Kentaro; Takahashi, Motomichi; Takahashi, Satoshi; Okubo, Torahiko

    2015-01-01

    We report the draft genome sequence of Chlamydia trachomatis strain 54, isolated from the urogenital tract of a male in Japan, with unique polymorphic membrane proteins. Detailed genomic analysis will aid our understanding of the selective pressures that lead to sexual differentiation in chlamydial adaptive evolution. PMID:26494683

  17. Draft Whole-Genome Sequence of a Haemophilus quentini Strain Isolated from an Infant in the United Kingdom

    PubMed Central

    Baxter, Laura; Thompson, Sarah; Collery, Mark M.; Hand, Daniel C.; Fink, Colin G.

    2016-01-01

    Haemophilus quentini is a rare and distinct genospecies of Haemophilus that has been suggested as a cause of neonatal bacteremia and urinary tract infections in men. We present the draft whole-genome sequence of H. quentini MP1 isolated from an infant in the United Kingdom, aiding future identification and detection of this pathogen.

  18. Draft Genome Sequence of the Aromatic Hydrocarbon-Degrading Bacterium Sphingobium sp. Strain Ant17, Isolated from Antarctic Soil

    PubMed Central

    Guerrero, Leandro D.; Makhalanyane, Thulani P.; Aislabie, Jackie M.

    2014-01-01

    Here, we present the draft genome sequence of Sphingobium sp. strain Ant17, an aromatic hydrocarbon-degrading bacterium that was isolated from Antarctic oil-contaminated soil. An analysis of this genome can lead to insights into the mechanisms of xenobiotic degradation processes at low temperatures and potentially aid in bioremediation applications. PMID:24723703

  19. Draft Genome Sequences of 18 Strains of Pseudomonas Isolated from Kiwifruit Plants in New Zealand and Overseas

    PubMed Central

    Fiers, Mark; Lu, Ashley; Panda, Preetinanda; Taylor, Robert; Pitman, Andrew R.

    2016-01-01

    In this paper, we present the draft sequences of 18 genetically diverse Pseudomonas strains isolated from kiwifruit plants in New Zealand and overseas, including a number that are currently not fully characterized. These sequences will aid in the diagnosis of Pseudomonas on kiwifruit for future pest management and border security decision-making. PMID:27056212

  20. Draft Genome Sequences of 18 Strains of Pseudomonas Isolated from Kiwifruit Plants in New Zealand and Overseas.

    PubMed

    Visnovsky, Sandra B; Fiers, Mark; Lu, Ashley; Panda, Preetinanda; Taylor, Robert; Pitman, Andrew R

    2016-01-01

    In this paper, we present the draft sequences of 18 genetically diversePseudomonasstrains isolated from kiwifruit plants in New Zealand and overseas, including a number that are currently not fully characterized. These sequences will aid in the diagnosis ofPseudomonason kiwifruit for future pest management and border security decision-making. PMID:27056212

  1. Drafting with Design in Mind

    ERIC Educational Resources Information Center

    Daugherty, Michael K.; Carter, Vinson

    2011-01-01

    Design and drafting are subjects long taught in technology education, and subjects that retain high status in the profession. Admittedly, since the initial publication of Standards for Technological Literacy in 2000, design has taken on a larger role and meaning in the technology education profession. However, design continues to be delivered…

  2. Core Competencies for Basic Drafting.

    ERIC Educational Resources Information Center

    Werner, Claire; Calderon, Ray

    These competencies for drafting are designed to cover basic principles and practices for beginning drafters. Each competency appears in a one-page format. It is presented as a goal statement followed by one or more "indicator" statements, which are performance objectives describing an ability that, upon attainment, will establish competency for…

  3. Drafting Series. Duty Task List.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This task list is intended for use in planning and/or evaluating a competency-based course in drafting. The tasks required to perform the duties of seven types of drafters (i.e., general, architectural, electronic, civil, structural, mechanical, and process pipe drafters) and technical illustrators are outlined. The following are among the duties…

  4. Mechanical Drafting. Student Learning Guides.

    ERIC Educational Resources Information Center

    Ridge Vocational-Technical Center, Winter Haven, FL.

    These four learning guides are self-instructional packets for four tasks identified as essential for performance on an entry-level job in mechanical drafting. Each guide is based on a terminal performance objective (task) and 2-4 enabling objectives. For each enabling objective, some or all of these materials may be presented: learning steps…

  5. Drafting. Occupational Competency Analysis Profile.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Vocational Instructional Materials Lab.

    This Drafting Occupational Competency Analysis Profile (OCAP) is one of a series of competency lists, verified by expert workers, that have evolved from a modified DACUM (Developing a Curriculum) job analysis process involving business, industry, labor, and community agency representatives from throughout Ohio. This OCAP identifies the…

  6. Drafting. Performance Objectives. Basic Course.

    ERIC Educational Resources Information Center

    Allen, Charles

    Several intermediate performance objectives and corresponding criterion measures are listed for each of 12 terminal objectives for a basic drafting course. The materials were developed for a two-semester course (2 hours daily). The organized classroom and shop experiences are designed to enable the student to develop general competencies in the…

  7. An Improved CAD System for Breast Cancer Diagnosis Based on Generalized Pseudo-Zernike Moment and Ada-DEWNN Classifier.

    PubMed

    Singh, Satya P; Urooj, Shabana

    2016-04-01

    In this paper, a novel framework of computer-aided diagnosis (CAD) system has been presented for the classification of benign/malignant breast tissues. The properties of the generalized pseudo-Zernike moments (GPZM) and pseudo-Zernike moments (PZM) are utilized as suitable texture descriptors of the suspicious region in the mammogram. An improved classifier- adaptive differential evolution wavelet neural network (Ada-DEWNN) is proposed to improve the classification accuracy of the CAD system. The efficiency of the proposed system is tested on mammograms from the Mammographic Image Analysis Society (mini-MIAS) database using the leave-one-out cross validation as well as on mammograms from the Digital Database for Screening Mammography (DDSM) database using 10-fold cross validation. The proposed method on MIAS-database attains a fair accuracy of 0.8938 and AUC of 0.935 (95 % CI = 0.8213-0.9831). The proposed method is also tested for in-plane rotation and found to be highly rotation invariant. In addition, the proposed classifier is tested and compared with some well-known existing methods using receiver operating characteristic (ROC) analysis using DDSM- database. It is concluded the proposed classifier has better area under the curve (AUC) (0.9289) and highly précised with 95 % CI, 0.8216 to 0.9834 and 0.0384 standard error.

  8. CAD system for the assistance of a comparative reading for lung cancer using retrospective helical CT images

    NASA Astrophysics Data System (ADS)

    Kubo, Mitsuru; Yamamoto, Takuya; Kawata, Yoshiki; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kakinuma, Ryutaro; Kaneko, Masahiro; Kusumoto, Masahiko; Moriyama, Noriyuki; Mori, Kiyoshi; Nishiyama, Hiroyuki

    2001-07-01

    The objective of our study is to develop a new computer- aided diagnosis (CAD) system to support effectually the comparative reading using serial helical CT images for lung cancer screening without using the film display. The placement of pulmonary shadows between the serial helical CT images is sometimes different to change the size and the shape of lung by inspired air. We analyzed the motion of the pulmonary structure using the serial cases of 17 pairs, which are different in the inspired air. This algorithm consists of the extraction process of region of interest such as the lung, heart and blood vessels region using thresholding and fuzzy c-means method, and the comparison process of each region in serial CT images using template matching. We validated the efficiency of this algorithm by application to image of 60 subjects. The algorithm could compare the slice images correctly in most combinations with respect to physician's point of view. The experimental results of the proposed algorithm indicate that our CAD system without using the film display is useful to increase the efficiency of the mass screening process.

  9. A prostate CAD system based on multiparametric analysis of DCE T1-w, and DW automatically registered images

    NASA Astrophysics Data System (ADS)

    Giannini, Valentina; Vignati, Anna; Mazzetti, Simone; De Luca, Massimo; Bracco, Christian; Stasi, Michele; Russo, Filippo; Armando, Enrico; Regge, Daniele

    2013-02-01

    Prostate specific antigen (PSA)-based screening reduces the rate of death from prostate cancer (PCa) by 31%, but this benefit is associated with a high risk of overdiagnosis and overtreatment. As prostate transrectal ultrasound-guided biopsy, the standard procedure for prostate histological sampling, has a sensitivity of 77% with a considerable false-negative rate, more accurate methods need to be found to detect or rule out significant disease. Prostate magnetic resonance imaging has the potential to improve the specificity of PSA-based screening scenarios as a non-invasive detection tool, in particular exploiting the combination of anatomical and functional information in a multiparametric framework. The purpose of this study was to describe a computer aided diagnosis (CAD) method that automatically produces a malignancy likelihood map by combining information from dynamic contrast enhanced MR images and diffusion weighted images. The CAD system consists of multiple sequential stages, from a preliminary registration of images of different sequences, in order to correct for susceptibility deformation and/or movement artifacts, to a Bayesian classifier, which fused all the extracted features into a probability map. The promising results (AUROC=0.87) should be validated on a larger dataset, but they suggest that the discrimination on a voxel basis between benign and malignant tissues is feasible with good performances. This method can be of benefit to improve the diagnostic accuracy of the radiologist, reduce reader variability and speed up the reading time, automatically highlighting probably cancer suspicious regions.

  10. An Improved CAD System for Breast Cancer Diagnosis Based on Generalized Pseudo-Zernike Moment and Ada-DEWNN Classifier.

    PubMed

    Singh, Satya P; Urooj, Shabana

    2016-04-01

    In this paper, a novel framework of computer-aided diagnosis (CAD) system has been presented for the classification of benign/malignant breast tissues. The properties of the generalized pseudo-Zernike moments (GPZM) and pseudo-Zernike moments (PZM) are utilized as suitable texture descriptors of the suspicious region in the mammogram. An improved classifier- adaptive differential evolution wavelet neural network (Ada-DEWNN) is proposed to improve the classification accuracy of the CAD system. The efficiency of the proposed system is tested on mammograms from the Mammographic Image Analysis Society (mini-MIAS) database using the leave-one-out cross validation as well as on mammograms from the Digital Database for Screening Mammography (DDSM) database using 10-fold cross validation. The proposed method on MIAS-database attains a fair accuracy of 0.8938 and AUC of 0.935 (95 % CI = 0.8213-0.9831). The proposed method is also tested for in-plane rotation and found to be highly rotation invariant. In addition, the proposed classifier is tested and compared with some well-known existing methods using receiver operating characteristic (ROC) analysis using DDSM- database. It is concluded the proposed classifier has better area under the curve (AUC) (0.9289) and highly précised with 95 % CI, 0.8216 to 0.9834 and 0.0384 standard error. PMID:26892455

  11. Computer-aided detection of breast masses depicted on full-field digital mammograms: a performance assessment

    PubMed Central

    Zheng, B; Sumkin, J H; Zuley, M L; Lederman, D; Wang, X; Gur, D

    2012-01-01

    Objectives To investigate the feasibility of converting a computer–aided detection (CAD) scheme for digitised screen–film mammograms to full-field digital mammograms (FFDMs) and assessing CAD performance on a large database. Methods The database included 6478 FFDM images acquired on 1120 females, with 525 cancer cases and 595 negative cases. The database was divided into five case groups: (1) cancer detected during screening, (2) interval cancers, (3) “high-risk” recommended for surgical excision, (4) recalled but negative and (5) negative (not recalled). A previously developed CAD scheme for masses depicted on digitised images was converted and re-optimised for FFDM images while keeping the same image-processing structure. CAD performance was analysed on the entire database. Results The case-based sensitivity was 75.6% (397/525) for the current mammograms and 40.8% (42/103) for the prior mammograms deemed negative during clinical interpretation but “visible” during retrospective review. The region-based sensitivity was 58.1% (618/1064) for the current mammograms and 28.4% (57/201) for the prior mammograms. The CAD scheme marked 55.7% (221/397) and 35.7% (15/42) of the masses on both views of the current and the prior examinations, respectively. The overall CAD-cued false-positive rate was 0.32 per image, ranging from 0.29 to 0.51 for the five case groups. Conclusion This study indicated that (1) digitised image-based CAD can be converted for FFDMs while performing at a comparable, or better, level; (2) CAD detects a substantial fraction of cancers depicted on prior examinations, albeit most having been marked only on one view; and (3) CAD tends to mark more false-positive results on “difficult” negative cases that are more visually difficult for radiologists to interpret. PMID:21343322

  12. Advances in computer-aided design and computer-aided manufacture technology.

    PubMed

    Calamia, J R

    1994-01-01

    Although the development of computer-aided design (CAD) and computer-aided manufacture (CAM) technology and the benefits of increased productivity became obvious in the automobile and aerospace industries in the 1970s, investigations of this technology's application in the field of dentistry did not begin until the 1980s. Only now are we beginning to see the fruits of this work with the commercial availability of some systems; the potential for this technology seems boundless. This article reviews the recent literature with emphasis on the period from June 1992 to May 1993. This review should familiarize the reader with some of the latest developments in this technology, including a brief description of some systems currently available and the clinical and economical rationale for their acceptance into the dental mainstream. This article concentrates on a particular system, the Cerec (Siemens/Pelton and Crane, Charlotte, NC) system, for three reasons: first, this system has been available since 1985 and, as a result, has a track record of almost 7 years of data. Most of the data have just recently been released and consequently, much of this year's literature on CAD-CAM is monopolized by studies using this system. Second, this system was developed as a mobile, affordable, direct chairside CAD-CAM restorative method. As such, it is of special interest to the dentist who will offer this new technology directly to the patient, providing a one-visit restoration. Third, the author is currently engaged in research using this particular system and has a working knowledge of this system's capabilities.

  13. Microwave processing of a dental ceramic used in computer-aided design/computer-aided manufacturing.

    PubMed

    Pendola, Martin; Saha, Subrata

    2015-01-01

    Because of their favorable mechanical properties and natural esthetics, ceramics are widely used in restorative dentistry. The conventional ceramic sintering process required for their use is usually slow, however, and the equipment has an elevated energy consumption. Sintering processes that use microwaves have several advantages compared to regular sintering: shorter processing times, lower energy consumption, and the capacity for volumetric heating. The objective of this study was to test the mechanical properties of a dental ceramic used in computer-aided design/computer-aided manufacturing (CAD/CAM) after the specimens were processed with microwave hybrid sintering. Density, hardness, and bending strength were measured. When ceramic specimens were sintered with microwaves, the processing times were reduced and protocols were simplified. Hardness was improved almost 20% compared to regular sintering, and flexural strength measurements suggested that specimens were approximately 50% stronger than specimens sintered in a conventional system. Microwave hybrid sintering may preserve or improve the mechanical properties of dental ceramics designed for CAD/CAM processing systems, reducing processing and waiting times.

  14. Comparisons of Wilson-Fowler and Parametric Cubic Splines with the Curve-Fitting Algorithms of Several Computer-Aided Design Systems

    SciTech Connect

    Birchler, W.D.; Schilling, S.A.

    2001-02-01

    The purpose of this report is to demonstrate that modern computer-aided design (CAD), computer-aided manufacturing (CAM), and computer-aided engineering (CAE) systems can be used in the Department of Energy (DOE) Nuclear Weapons Complex (NWC) to design new and remodel old products, fabricate old and new parts, and reproduce legacy data within the inspection uncertainty limits. In this study, two two-dimensional splines are compared with several modern CAD curve-fitting modeling algorithms. The first curve-fitting algorithm is called the Wilson-Fowler Spline (WFS), and the second is called a parametric cubic spline (PCS). Modern CAD systems usually utilize either parametric cubic and/or B-splines.

  15. Automated knowledge base development from CAD/CAE databases

    NASA Technical Reports Server (NTRS)

    Wright, R. Glenn; Blanchard, Mary

    1988-01-01

    Knowledge base development requires a substantial investment in time, money, and resources in order to capture the knowledge and information necessary for anything other than trivial applications. This paper addresses a means to integrate the design and knowledge base development process through automated knowledge base development from CAD/CAE databases and files. Benefits of this approach include the development of a more efficient means of knowledge engineering, resulting in the timely creation of large knowledge based systems that are inherently free of error.

  16. Intelligent machining of rough components from optimized CAD models

    NASA Astrophysics Data System (ADS)

    Lewis, Geoff; Thompson, William

    1995-08-01

    This paper describes a technique for automatically generating NC machine programs from CAD images of a rough work piece and an optimally positioned component. The paper briefly compares the generative and variant methods of automatic machine program development and then presents a technique based on the variant method where a reference machine program is transformed to machine the optimized component. The transformed machine program is examined to remove any redundant cutter motions and correct any invalid cutter motions. The research is part of a larger project on intelligent manufacturing systems and is being conducted at the CIM Centre, Swinburne University of Technology, Hawthorn, Australia.

  17. CAD/CAM and scientific data management at Dassault

    NASA Technical Reports Server (NTRS)

    Bohn, P.

    1984-01-01

    The history of CAD/CAM and scientific data management at Dassault are presented. Emphasis is put on the targets of the now commercially available software CATIA. The links with scientific computations such as aerodynamics and structural analysis are presented. Comments are made on the principles followed within the company. The consequences of the approximative nature of scientific data are examined. Consequence of the new history function is mainly its protection against copy or alteration. Future plans at Dassault for scientific data appear to be in opposite directions compared to some general tendencies.

  18. Steam turbine generators -from NC manufacturing to CAD/CAM

    SciTech Connect

    Searle, D.R.; King, F.E.; Kiniskern, J.M.

    1985-04-01

    A program has been designed to integrate engineering, manufacturing, and business systems using a common data base. There has been a significant increase in benefits obtained by extending the automation of the design/drafting function to include manufacturing operations. This extension would have been difficult without the existence of highly developed family-of-parts NC programs. The integration concept has also been applied to turbine buckets and is being extended to other turning-generator components.

  19. Computer-aided diagnosis of lumbar stenosis conditions

    NASA Astrophysics Data System (ADS)

    Koompairojn, Soontharee; Hua, Kathleen; Hua, Kien A.; Srisomboon, Jintavaree

    2010-03-01

    Computer-aided diagnosis (CAD) systems are indispensable tools for patients' healthcare in modern medicine. Nevertheless, the only fully automatic CAD system available for lumbar stenosis today is for X-ray images. Its performance is limited due to the limitations intrinsic to X-ray images. In this paper, we present a system for magnetic resonance images. It employs a machine learning classification technique to automatically recognize lumbar spine components. Features can then be extracted from these spinal components. Finally, diagnosis is done by applying a Multilayer Perceptron. This classification framework can learn the features of different spinal conditions from the training images. The trained Perceptron can then be applied to diagnose new cases for various spinal conditions. Our experimental studies based on 62 subjects indicate that the proposed system is reliable and significantly better than our older system for X-ray images.

  20. CAD System for Pulmonary Nodule Detection Using Gabor Filtering and Template Matching

    NASA Astrophysics Data System (ADS)

    Bastawrous, Hany Ayad; Nitta, Norihisa; Tsudagawa, Masaru

    This paper aims at developing a Computer Aided Diagnosis (CAD) system used for the detection of pulmonary nodules in chest Computed Tomography (CT) images. These lung nodules include both solid nodules and Ground Glass Opacity (GGO) nodules. In our scheme, we apply Gabor filter on the CT image in order to enhance the detection process. After this we perform some morphological operations including threshold process and labeling to extract all the objects inside the lung area. Then, some feature analysis is used to examine these objects to decide which of them are likely to be potential cancer candidates. Following the feature examination, a template matching between the potential cancer candidates and some Gaussian reference models is performed to determine the similarity between them. The algorithm was applied on 715 slices containing 25 GGO nodules and 82 solid nodules and achieved detection sensitivity of 92% for GGO nodules and 95% for solid nodules with False Positive (FP) rate of 0.75 FP/slice for GGO nodules and 2.32 FP/slice for solid nodules. Finally, we used an Artificial Neural Network (ANN) to reduce the number of FP findings. After using ANN, we were able to reduce the FP rate to 0.25 FP/slice for GGO nodules and 1.62 FP/slice for solid nodules but at the expense of detection sensitivity, which became 84 % for GGO nodules and 91% for solid nodules.

  1. A technique for developing CAD geometry of long bones using clinical CT data.

    PubMed

    Davis, Matthew L; Vavalle, Nicholas A; Stitzel, Joel D; Gayzik, F Scott

    2015-11-01

    Computed tomography scans are a valuable tool for developing computational models of bones. The objective of this study is to present a method to generate CAD representations of long bones from clinically based CT scans. A secondary aim is to apply the method to six long bones from a sample of three individuals. Periosteal and endosteal bone surfaces were segmented and used to calculate the characteristic cortical thickness, Tc, at 1 mm increments along the bone axis. In the epiphyses where the value of Tc fell below the scanner threshold, the endosteal bone layer was replaced using literature values projected inward from the periosteal surface. On average, 74.7 ± 7.4% of the bone geometry was above the scanner cut-off and was therefore derived from the CT scan data. The thickness measurement was also compared to experimental measurements of cadaveric bone and was found to predict Tc with an error of 3.1%. This method presents a possible solution for the characterization of characteristic thickness along the length of the bone and may also aid in the development of orthopedic implant design and subject specific finite element models.

  2. Using the Laser Engineered Net Shaping (LENS{trademark}) process to produce complex components from a CAD solid model

    SciTech Connect

    Smugeresky, J.E.; Keicher, D.M.; Romero, J.A.; Griffith, M.L.; Harwell, L.D.

    1997-08-01

    The Laser Engineered Net Shaping (LENS{trademark}) process, currently under development, has demonstrated the capability to produce near-net shape, fully dense metallic parts with reasonably complex geometrical features directly from a Computer-Aided Design (CAD) solid model. Using a highly localized laser beam, metal powders are used to produce very fine grain high strength structures. Results to date show that excellent mechanical properties can be achieved in alloys such as 316 stainless steel and Inconel 625. Significant increases in yield strength have been achieved with no loss in ductility. The current approach lends itself to produce components with a dimensional accuracy of {+-} 0.002 inches in the deposition plane and {+-} 0.015 inches in the growth direction. These results suggest that the LENS{trademark} process will provide a viable means for direct fabrication of metallic hardware.

  3. Parametric bicubic spline and CAD tools for complex targets shape modelling in physical optics radar cross section prediction

    NASA Astrophysics Data System (ADS)

    Delogu, A.; Furini, F.

    1991-09-01

    Increasing interest in radar cross section (RCS) reduction is placing new demands on theoretical, computation, and graphic techniques for calculating scattering properties of complex targets. In particular, computer codes capable of predicting the RCS of an entire aircraft at high frequency and of achieving RCS control with modest structural changes, are becoming of paramount importance in stealth design. A computer code, evaluating the RCS of arbitrary shaped metallic objects that are computer aided design (CAD) generated, and its validation with measurements carried out using ALENIA RCS test facilities are presented. The code, based on the physical optics method, is characterized by an efficient integration algorithm with error control, in order to contain the computer time within acceptable limits, and by an accurate parametric representation of the target surface in terms of bicubic splines.

  4. SVM-based CAD system for early detection of the Alzheimer's disease using kernel PCA and LDA.

    PubMed

    López, M M; Ramírez, J; Górriz, J M; Alvarez, I; Salas-Gonzalez, D; Segovia, F; Chaves, R

    2009-10-30

    Single-photon emission tomography (SPECT) imaging has been widely used to guide clinicians in the early Alzheimer's disease (AD) diagnosis challenge. However, AD detection still relies on subjective steps carried out by clinicians, which entail in some way subjectivity to the final diagnosis. In this work, kernel principal component analysis (PCA) and linear discriminant analysis (LDA) are applied on functional images as dimension reduction and feature extraction techniques, which are subsequently used to train a supervised support vector machine (SVM) classifier. The complete methodology provides a kernel-based computer-aided diagnosis (CAD) system capable to distinguish AD from normal subjects with 92.31% accuracy rate for a SPECT database consisting of 91 patients. The proposed methodology outperforms voxels-as-features (VAF) that was considered as baseline approach, which yields 80.22% for the same SPECT database.

  5. HDL subfractions and very early CAD: novel findings from untreated patients in a Chinese cohort.

    PubMed

    Zhang, Yan; Zhu, Cheng-Gang; Xu, Rui-Xia; Li, Sha; Li, Xiao-Lin; Guo, Yuan-Lin; Wu, Na-Qiong; Gao, Ying; Qing, Ping; Cui, Chuan-Jue; Sun, Jing; Li, Jian-Jun

    2016-01-01

    Coronary artery disease (CAD) in very young individuals is a rare disease associated with poor prognosis. However, the role of specific lipoprotein subfractions in very young CAD patients (≤45 years) is not established yet. A total of 734 consecutive CAD subjects were enrolled and were classified as very early (n = 81, ≤45), early (n = 304, male: 45-55; female: 45-65), and late (n = 349, male: >55; female: >65) groups. Meanwhile, a group of non-CAD subjects were also enrolled as controls (n = 56, ≤45). The lipoprotein separation was performed using Lipoprint System. As a result, the very early CAD patients have lower large high-density lipoprotein (HDL) subfraction and higher small low-density lipoprotein (LDL) subfraction (p < 0.05). Although body mass index was inversely related to large HDL subfraction, overweight did not influence its association with very early CAD. In the logistic regression analysis, large HDL was inversely [OR 95% CI: 0.872 (0.825-0.922)] while small LDL was positively [1.038 (1.008-1.069)] related to very early CAD. However, after adjusting potential confounders, the association was only significant for large HDL [0.899 (0.848-0.954)]. This study firstly demonstrated that large HDL subfraction was negatively related to very early CAD suggestive of its important role in very early CAD incidence. PMID:27489174

  6. HDL subfractions and very early CAD: novel findings from untreated patients in a Chinese cohort

    PubMed Central

    Zhang, Yan; Zhu, Cheng-Gang; Xu, Rui-Xia; Li, Sha; Li, Xiao-Lin; Guo, Yuan-Lin; Wu, Na-Qiong; Gao, Ying; Qing, Ping; Cui, Chuan-Jue; Sun, Jing; Li, Jian-Jun

    2016-01-01

    Coronary artery disease (CAD) in very young individuals is a rare disease associated with poor prognosis. However, the role of specific lipoprotein subfractions in very young CAD patients (≤45 years) is not established yet. A total of 734 consecutive CAD subjects were enrolled and were classified as very early (n = 81, ≤45), early (n = 304, male: 45–55; female: 45–65), and late (n = 349, male: >55; female: >65) groups. Meanwhile, a group of non-CAD subjects were also enrolled as controls (n = 56, ≤45). The lipoprotein separation was performed using Lipoprint System. As a result, the very early CAD patients have lower large high-density lipoprotein (HDL) subfraction and higher small low-density lipoprotein (LDL) subfraction (p < 0.05). Although body mass index was inversely related to large HDL subfraction, overweight did not influence its association with very early CAD. In the logistic regression analysis, large HDL was inversely [OR 95% CI: 0.872 (0.825–0.922)] while small LDL was positively [1.038 (1.008–1.069)] related to very early CAD. However, after adjusting potential confounders, the association was only significant for large HDL [0.899 (0.848–0.954)]. This study firstly demonstrated that large HDL subfraction was negatively related to very early CAD suggestive of its important role in very early CAD incidence. PMID:27489174

  7. Crawling Aid

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The Institute for the Achievement of Human Potential developed a device known as the Vehicle for Initial Crawling (VIC); the acronym is a tribute to the crawler's inventor, Hubert "Vic" Vykukal; is an effective crawling aid. The VIC is used by brain injured children who are unable to crawl due to the problems of weight-bearing and friction, caused by gravity. It is a rounded plywood frame large enough to support the child's torso, leaving arms and legs free to move. On its underside are three aluminum discs through which air is pumped to create an air-bearing surface that has less friction than a film of oil. Upper side contains the connection to the air supply and a pair of straps which restrain the child and cause the device to move with him. VIC is used with the intent to recreate the normal neurological connection between brain and muscles. Over repetitive use of the device the child develops his arm and leg muscles as well as coordination. Children are given alternating therapy, with and without the VIC until eventually the device is no longer needed.

  8. 77 FR 35688 - Draft and Revised Draft Guidances for Industry Describing Product-Specific Bioequivalence...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-14

    ... HUMAN SERVICES Food and Drug Administration Draft and Revised Draft Guidances for Industry Describing Product-Specific Bioequivalence Recommendations; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing the availability...

  9. 46 CFR 167.55-1 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... NAUTICAL SCHOOL SHIPS Special Markings Required § 167.55-1 Draft marks and draft indicating systems. (a... rudderpost or at any place at the stern of the vessel as may be necessary for easy observance. The bottom...

  10. 46 CFR 167.55-1 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... NAUTICAL SCHOOL SHIPS Special Markings Required § 167.55-1 Draft marks and draft indicating systems. (a... rudderpost or at any place at the stern of the vessel as may be necessary for easy observance. The bottom...

  11. 46 CFR 32.05-1 - Draft marks and draft indicating systems-TB/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or... aft to the location of the draft marks, due to raked stem or cutaway skeg, the datum line from...

  12. 46 CFR 32.05-1 - Draft marks and draft indicating systems-TB/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or... aft to the location of the draft marks, due to raked stem or cutaway skeg, the datum line from...

  13. 46 CFR 97.40-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or... aft to the location of the draft marks, due to raked stem or cut away skeg, the datum line from...

  14. 46 CFR 196.40-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or... aft to the location of the draft marks, due to raked stem, or cutaway skeg, the datum line from...

  15. Nitrogenase: A Draft Mechanism

    PubMed Central

    Hoffman, Brian M.; Lukoyanov, Dmitriy; Dean, Dennis R.; Seefeldt, Lance C.

    2013-01-01

    consideration of previous studies, imply a pathway in which (i) N2 binds at E4 with liberation of H2, (ii) N2 is promptly reduced to N2H2, (iii) the two N’s are hydrogenated alternately to form hydrazine-bound FeMo-co, and (iv) two NH3 are liberated in two further steps of reduction. This proposal identifies nitrogenase as following a ‘Prompt-Alternating (P-A)’ reaction pathway, and unifies the catalytic pathway with the LT kinetic framework. However, it does not incorporate one of the most puzzling aspects of nitrogenase catalysis: obligatory generation of H2 upon N2 binding that apparently ‘wastes’ two reducing equivalents and thus 25% of the total energy supplied by the hydrolysis of ATP. The finding that E4 stores its four accumulated reducing equivalents as two bridging hydrides, considered in the context of the organometallic chemistries of hydrides and dihydrogen, leads us to propose an answer to this puzzle. Namely, that H2 release upon N2 binding involves reductive elimination of two hydrides to yield N2 bound to doubly reduced Fe. Coupled delivery of the two available electrons and two activating protons yields cofactor-bound diazene, in keeping with the P-A scheme. This keystone completes a draft mechanism for nitrogenase that organizes the vast body of data upon which it is formulated, and is intended to serve as a basis for future experiments. PMID:23289741

  16. HIV-AIDS Connection

    MedlinePlus

    ... Marketing Share this: Main Content Area The HIV-AIDS Connection AIDS was first recognized in 1981 and ... is there overwhelming scientific consensus that HIV causes AIDS? Before HIV infection became widespread in the human ...

  17. Heart attack first aid

    MedlinePlus

    First aid - heart attack; First aid - cardiopulmonary arrest; First aid - cardiac arrest ... of patients with unstable angina/non-ST-elevation myocardial infarction (updating the 2007 guideline and replacing the 2011 ...

  18. Splinter, First Aid

    MedlinePlus

    ... and rashes clinical tools newsletter | contact Share | Splinter, First Aid A A A First Aid for Splinter: View ... wet, it makes the area prone to infection. First Aid Guide Self-care measures to remove a splinter ...

  19. A vision-aided alignment datum system for coordinate measuring machines

    NASA Astrophysics Data System (ADS)

    Wang, L.; Lin, G. C. I.

    1997-07-01

    This paper presents the development of a CAD-based and vision-aided precision measurement system. A new coordinate system alignment technique for coordinate measuring machines (CMMs) is described. This alignment technique involves a machine vision system with CAD-based planning and execution of inspection. The determination method for measuring datums for the coordinate measuring technique, using the AutoCAD development system, is described in more detail. To improve image quality in the machine vision system, a contrast enhancement technique is used on the image background to reduce image noise, and an on-line calibration technique is applied. Some systematic errors may be caused by imperfect geometric features in components during coordinate system alignment. This measurement system approach, with its new measuring coordinate alignment method, can be used for high-precision measurement to overcome such errors.

  20. Predictive deconvolution and hybrid feature selection for computer-aided detection of prostate cancer.

    PubMed

    Maggio, Simona; Palladini, Alessandro; Marchi, Luca De; Alessandrini, Martino; Speciale, Nicolò; Masetti, Guido

    2010-02-01

    Computer-aided detection (CAD) schemes are decision making support tools, useful to overcome limitations of problematic clinical procedures. Trans-rectal ultrasound image based CAD would be extremely important to support prostate cancer diagnosis. An effective approach to realize a CAD scheme for this purpose is described in this work, employing a multi-feature kernel classification model based on generalized discriminant analysis. The mutual information of feature value and tissue pathological state is used to select features essential for tissue characterization. System-dependent effects are reduced through predictive deconvolution of the acquired radio-frequency signals. A clinical study, performed on ground truth images from biopsy findings, provides a comparison of the classification model applied before and after deconvolution, showing in the latter case a significant gain in accuracy and area under the receiver operating characteristic curve.