Sample records for air puff tonometry

  1. The influence of intraocular pressure and air jet pressure on corneal contactless tonometry tests.

    PubMed

    Simonini, Irene; Pandolfi, Anna

    2016-05-01

    The air puff is a dynamic contactless tonometer test used in ophthalmology clinical practice to assess the biomechanical properties of the human cornea and the intraocular pressure due to the filling fluids of the eye. The test is controversial, since the dynamic response of the cornea is governed by the interaction of several factors which cannot be discerned within a single measurement. In this study we describe a numerical model of the air puff tests, and perform a parametric analysis on the major action parameters (jet pressure and intraocular pressure) to assess their relevance on the mechanical response of a patient-specific cornea. The particular cornea considered here has been treated with laser reprofiling to correct myopia, and the parametric study has been conducted on both the preoperative and postoperative geometries. The material properties of the cornea have been obtained by means of an identification procedure that compares the static biomechanical response of preoperative and postoperative corneas under the physiological IOP. The parametric study on the intraocular pressure suggests that the displacement of the cornea׳s apex can be a reliable indicator for tonometry, and the one on the air jet pressure predicts the outcomes of two or more distinct measurements on the same cornea, which can be used in inverse procedures to estimate the material properties of the tissue. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Eye retraction and rotation during Corvis ST 'air puff' intraocular pressure measurement and its quantitative analysis.

    PubMed

    Boszczyk, Agnieszka; Kasprzak, Henryk; Jóźwik, Agnieszka

    2017-05-01

    The aim of this study was to analyse the indentation and deformation of the corneal surface, as well as eye retraction, which occur during air puff intraocular pressure (IOP) measurement. A group of 10 subjects was examined using a non-contact Corvis ST tonometer, which records image sequences of corneas deformed by an air puff. Obtained images were processed numerically in order to extract information about corneal deformation, indentation and eyeball retraction. The time dependency of the apex deformation/eye retraction ratio and the curve of dependency between apex indentation and eye retraction take characteristic shapes for individual subjects. It was noticed that the eye globes tend to rotate towards the nose in response to the air blast during measurement. This means that the eye globe not only displaces but also rotates during retraction. Some new parameters describing the shape of this curve are introduced. Our data show that intraocular pressure and amplitude of corneal indentation are inversely related (r 8  = -0.83, P = 0.0029), but the correlation between intraocular pressure and amplitude of eye retraction is low and not significant (r 8  = -0.24, P = 0.51). The curves describing corneal behaviour during air puff tonometry were determined and show that the eye globe rotates towards the nose during measurement. In addition, eye retraction amplitudes may be related to elastic or viscoelastic properties of deeper structures in the eye or behind the eye and this should be further investigated. Many of the proposed new parameters present comparable or even higher repeatability than the standard parameters provided by the Corvis ST. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  3. Air puff-induced 22-kHz calls in F344 rats.

    PubMed

    Inagaki, Hideaki; Sato, Jun

    2016-03-01

    Air puff-induced ultrasonic vocalizations in adult rats, termed "22-kHz calls," have been applied as a useful animal model to develop psychoneurological and psychopharmacological studies focusing on human aversive affective disorders. To date, all previous studies on air puff-induced 22-kHz calls have used outbred rats. Furthermore, newly developed gene targeting technologies, which are essential for further advancement of biomedical experiments using air puff-induced 22-kHz calls, have enabled the production of genetically modified rats using inbred rat strains. Therefore, we considered it necessary to assess air puff-induced 22-kHz calls in inbred rats. In this study, we assessed differences in air puff-induced 22-kHz calls between inbred F344 rats and outbred Wistar rats. Male F344 rats displayed similar total (summed) duration of air puff-induced 22 kHz vocalizations to that of male Wistar rats, however, Wistar rats emitted fewer calls of longer duration, while F344 rats emitted higher number of vocalizations of shorter duration. Additionally, female F344 rats emitted fewer air puff-induced 22-kHz calls than did males, thus confirming the existence of a sex difference that was previously reported for outbred Wistar rats. The results of this study could confirm the reliability of air puff stimulus for induction of a similar amount of emissions of 22-kHz calls in different rat strains, enabling the use of air puff-induced 22-kHz calls in inbred F344 rats and derived genetically modified animals in future studies concerning human aversive affective disorders. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Material Properties from Air Puff Corneal Deformation by Numerical Simulations on Model Corneas.

    PubMed

    Bekesi, Nandor; Dorronsoro, Carlos; de la Hoz, Andrés; Marcos, Susana

    2016-01-01

    To validate a new method for reconstructing corneal biomechanical properties from air puff corneal deformation images using hydrogel polymer model corneas and porcine corneas. Air puff deformation imaging was performed on model eyes with artificial corneas made out of three different hydrogel materials with three different thicknesses and on porcine eyes, at constant intraocular pressure of 15 mmHg. The cornea air puff deformation was modeled using finite elements, and hyperelastic material parameters were determined through inverse modeling, minimizing the difference between the simulated and the measured central deformation amplitude and central-peripheral deformation ratio parameters. Uniaxial tensile tests were performed on the model cornea materials as well as on corneal strips, and the results were compared to stress-strain simulations assuming the reconstructed material parameters. The measured and simulated spatial and temporal profiles of the air puff deformation tests were in good agreement (< 7% average discrepancy). The simulated stress-strain curves of the studied hydrogel corneal materials fitted well the experimental stress-strain curves from uniaxial extensiometry, particularly in the 0-0.4 range. Equivalent Young´s moduli of the reconstructed material properties from air-puff were 0.31, 0.58 and 0.48 MPa for the three polymer materials respectively which differed < 1% from those obtained from extensiometry. The simulations of the same material but different thickness resulted in similar reconstructed material properties. The air-puff reconstructed average equivalent Young´s modulus of the porcine corneas was 1.3 MPa, within 18% of that obtained from extensiometry. Air puff corneal deformation imaging with inverse finite element modeling can retrieve material properties of model hydrogel polymer corneas and real corneas, which are in good correspondence with those obtained from uniaxial extensiometry, suggesting that this is a promising technique to retrieve quantitative corneal biomechanical properties.

  5. Material Properties from Air Puff Corneal Deformation by Numerical Simulations on Model Corneas

    PubMed Central

    Dorronsoro, Carlos; de la Hoz, Andrés; Marcos, Susana

    2016-01-01

    Objective To validate a new method for reconstructing corneal biomechanical properties from air puff corneal deformation images using hydrogel polymer model corneas and porcine corneas. Methods Air puff deformation imaging was performed on model eyes with artificial corneas made out of three different hydrogel materials with three different thicknesses and on porcine eyes, at constant intraocular pressure of 15 mmHg. The cornea air puff deformation was modeled using finite elements, and hyperelastic material parameters were determined through inverse modeling, minimizing the difference between the simulated and the measured central deformation amplitude and central-peripheral deformation ratio parameters. Uniaxial tensile tests were performed on the model cornea materials as well as on corneal strips, and the results were compared to stress-strain simulations assuming the reconstructed material parameters. Results The measured and simulated spatial and temporal profiles of the air puff deformation tests were in good agreement (< 7% average discrepancy). The simulated stress-strain curves of the studied hydrogel corneal materials fitted well the experimental stress-strain curves from uniaxial extensiometry, particularly in the 0–0.4 range. Equivalent Young´s moduli of the reconstructed material properties from air-puff were 0.31, 0.58 and 0.48 MPa for the three polymer materials respectively which differed < 1% from those obtained from extensiometry. The simulations of the same material but different thickness resulted in similar reconstructed material properties. The air-puff reconstructed average equivalent Young´s modulus of the porcine corneas was 1.3 MPa, within 18% of that obtained from extensiometry. Conclusions Air puff corneal deformation imaging with inverse finite element modeling can retrieve material properties of model hydrogel polymer corneas and real corneas, which are in good correspondence with those obtained from uniaxial extensiometry, suggesting that this is a promising technique to retrieve quantitative corneal biomechanical properties. PMID:27792759

  6. The modulatory effects of rostral ventromedial medulla on air-puff evoked microarousals in rats

    PubMed Central

    Foo, H.; Crabtree, Katherine; Mason, Peggy

    2010-01-01

    This study tested whether the duration of microarousals from sleep evoked by innocuous air-puff is affected by intra-RVM administration of neurotensin and bicuculline, pharmacological manipulations that affect ON and OFF cell activity. Air-puff evoked microarousal duration was unaffected by 0.05 ng neurotensin, but decreased by 502 ng neurotensin, and 5 and 50 ng bicuculline. These results suggest a putative role for OFF cells in protecting sleep from interruption by non-noxious stimuli. PMID:20621127

  7. Avian maternal response to chick distress

    PubMed Central

    Edgar, J. L.; Lowe, J. C.; Paul, E. S.; Nicol, C. J.

    2011-01-01

    The extent to which an animal is affected by the pain or distress of a conspecific will depend on its capacity for empathy. Empathy most probably evolved to facilitate parental care, so the current study assessed whether birds responded to an aversive stimulus directed at their chicks. Domestic hens were exposed to two replicates of the following conditions in a counterbalanced order: control (C; hen and chicks undisturbed), air puff to chicks (APC; air puff directed at chicks at 30 s intervals), air puff to hen (APH; air puff directed at hen at 30 s intervals) and control with noise (CN; noise of air puff at 30 s intervals). During each test, the hens' behaviour and physiology were measured throughout a 10 min pre-treatment and a 10 min treatment period. Hens responded to APH and APC treatments with increased alertness, decreased preening behaviour and a reduction in eye temperature. No such changes occurred during any control period. Increased heart rate and maternal vocalization occurred exclusively during the APC treatment, even though chicks produced few distress vocalizations. The pronounced and specific reaction observed indicates that adult female birds possess at least one of the essential underpinning attributes of empathy. PMID:21389025

  8. Can we trust intraocular pressure measurements in eyes with intracameral air?

    PubMed

    Jóhannesson, Gauti; Lindén, Christina; Eklund, Anders; Behndig, Anders; Hallberg, Per

    2014-10-01

    To evaluate the effect of intracameral air on intraocular pressure (IOP) measurements using Goldmann applanation tonometry (GAT) and applanation resonance tonometry (ART) in an in-vitro porcine eye model. IOP was measured on thirteen freshly enucleated eyes at three reference pressures: 20, 30, and 40 mmHg. Six measurements/method were performed in a standardized order with GAT and ART respectively. Air was injected intracamerally in the same manner as during Descemet's stripping endothelial keratoplasty (DSEK) and Descemet's membrane endothelial keratoplasty (DMEK), and the measurements were repeated. Measured IOP increased significantly for both tonometry methods after air injection: 0.7 ± 2.1 mmHg for GAT and 10.6 ± 4.9 mmHg for ART. This difference was significant at each reference pressure for ART but not for GAT. Although slightly affected, this study suggests that we can trust GAT IOP-measurements in eyes with intracameral air, such as after DSEK/DMEK operations. Ultrasound-based methods such as ART should not be used.

  9. Stress-free automatic sleep deprivation using air puffs

    PubMed Central

    Gross, Brooks A.; Vanderheyden, William M.; Urpa, Lea M.; Davis, Devon E.; Fitzpatrick, Christopher J.; Prabhu, Kaustubh; Poe, Gina R.

    2015-01-01

    Background Sleep deprivation via gentle handling is time-consuming and personnel-intensive. New Method We present here an automated sleep deprivation system via air puffs. Implanted EMG and EEG electrodes were used to assess sleep/waking states in six male Sprague-Dawley rats. Blood samples were collected from an implanted intravenous catheter every 4 hours during the 12-hour light cycle on baseline, 8 hours of sleep deprivation via air puffs, and 8 hours of sleep deprivation by gentle handling days. Results The automated system was capable of scoring sleep and waking states as accurately as our offline version (~90% for sleep) and with sufficient speed to trigger a feedback response within an acceptable amount of time (1.76 s). Manual state scoring confirmed normal sleep on the baseline day and sleep deprivation on the two manipulation days (68% decrease in non-REM, 63% decrease in REM, and 74% increase in waking). No significant differences in levels of ACTH and corticosterone (stress hormones indicative of HPA axis activity) were found at any time point between baseline sleep and sleep deprivation via air puffs. Comparison with Existing Method There were no significant differences in ACTH or corticosterone concentrations between sleep deprivation by air puffs and gentle handling over the 8-hour period. Conclusions Our system accurately detects sleep and delivers air puffs to acutely deprive rats of sleep with sufficient temporal resolution during the critical 4-5 h post learning sleep-dependent memory consolidation period. The system is stress-free and a viable alternative to existing sleep deprivation techniques. PMID:26014662

  10. Stress-free automatic sleep deprivation using air puffs.

    PubMed

    Gross, Brooks A; Vanderheyden, William M; Urpa, Lea M; Davis, Devon E; Fitzpatrick, Christopher J; Prabhu, Kaustubh; Poe, Gina R

    2015-08-15

    Sleep deprivation via gentle handling is time-consuming and personnel-intensive. We present here an automated sleep deprivation system via air puffs. Implanted EMG and EEG electrodes were used to assess sleep/waking states in six male Sprague-Dawley rats. Blood samples were collected from an implanted intravenous catheter every 4h during the 12-h light cycle on baseline, 8h of sleep deprivation via air puffs, and 8h of sleep deprivation by gentle handling days. The automated system was capable of scoring sleep and waking states as accurately as our offline version (∼90% for sleep) and with sufficient speed to trigger a feedback response within an acceptable amount of time (1.76s). Manual state scoring confirmed normal sleep on the baseline day and sleep deprivation on the two manipulation days (68% decrease in non-REM, 63% decrease in REM, and 74% increase in waking). No significant differences in levels of ACTH and corticosterone (stress hormones indicative of HPA axis activity) were found at any time point between baseline sleep and sleep deprivation via air puffs. There were no significant differences in ACTH or corticosterone concentrations between sleep deprivation by air puffs and gentle handling over the 8-h period. Our system accurately detects sleep and delivers air puffs to acutely deprive rats of sleep with sufficient temporal resolution during the critical 4-5h post learning sleep-dependent memory consolidation period. The system is stress-free and a viable alternative to existing sleep deprivation techniques. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Effects of design parameters and puff topography on heating coil temperature and mainstream aerosols in electronic cigarettes

    NASA Astrophysics Data System (ADS)

    Zhao, Tongke; Shu, Shi; Guo, Qiuju; Zhu, Yifang

    2016-06-01

    Emissions from electronic cigarettes (ECs) may contribute to both indoor and outdoor air pollution and the number of users is increasing rapidly. ECs operate based on the evaporation of e-liquid by a high-temperature heating coil. Both puff topography and design parameters can affect this evaporation process. In this study, both mainstream aerosols and heating coil temperature were measured concurrently to study the effects of design parameters and puff topography. The heating coil temperatures and mainstream aerosols varied over a wide range across different brands and within same brand. The peak heating coil temperature and the count median diameter (CMD) of EC aerosols increased with a longer puff duration and a lower puff flow rate. The particle number concentration was positively associated with the puff duration and puff flow rate. These results provide a better understanding of how EC emissions are affected by design parameters and puff topography and emphasize the urgent need to better regulate EC products.

  12. REINFORCING EFFECTS OF NICOTINE AND NON-NICOTINE COMPONENTS OF CIGARETTE SMOKE

    PubMed Central

    Rose, Jed E.; Salley, Al; Behm, Frederique M.; Bates, James E.; Westman, Eric C.

    2014-01-01

    We assessed the reinforcing effects of nicotine and non-nicotine components of cigarette smoke, by presenting a concurrent choice paradigm in which participants had access to intravenous (IV) nicotine infusions vs. saline (placebo) infusions and puffs from denicotinized (“denic”) cigarettes vs. air (sham puffs). We also measured the effects on self-administration of prior satiation with each component. Sixteen smokers participated in 7 sessions, consisting of: 1) a baseline smoking assessment, which was used to tailor the nicotine dose per infusion to that of puffs from subjects’ preferred brands of cigarettes; 2) two sessions in which participants were trained to discriminate IV nicotine vs. saline infusions and denic smoke vs. sham (air) puffs; and 3) four sessions assessing choice behavior after different satiation conditions. Results showed that subjects self-administered more puffs of denic smoke than any other alternative, including IV nicotine. IV nicotine, however, was preferred over IV saline and sham puffs. Preference for denic smoke vs. IV nicotine was highly correlated with subjective ratings of “comfort” associated with the two alternatives. Satiation with smoke diminished the number of denic puffs taken during choice periods, while prior administration of nicotine did not affect the number of puffs taken. Smoking withdrawal symptoms were alleviated both by nicotine administration and by denic smoke. These results show that in established smokers, non-nicotine aspects of cigarette smoking have potent reinforcing effects. While current smoking cessation pharmacotherapies primarily address the nicotine component of cigarette addiction, future cessation strategies should also be designed to target non-nicotine factors. PMID:20358364

  13. Corneal biomechanical properties from air-puff corneal deformation imaging

    NASA Astrophysics Data System (ADS)

    Marcos, Susana; Kling, Sabine; Bekesi, Nandor; Dorronsoro, Carlos

    2014-02-01

    The combination of air-puff systems with real-time corneal imaging (i.e. Optical Coherence Tomography (OCT), or Scheimpflug) is a promising approach to assess the dynamic biomechanical properties of the corneal tissue in vivo. In this study we present an experimental system which, together with finite element modeling, allows measurements of corneal biomechanical properties from corneal deformation imaging, both ex vivo and in vivo. A spectral OCT instrument combined with an air puff from a non-contact tonometer in a non-collinear configuration was used to image the corneal deformation over full corneal cross-sections, as well as to obtain high speed measurements of the temporal deformation of the corneal apex. Quantitative analysis allows direct extraction of several deformation parameters, such as apex indentation across time, maximal indentation depth, temporal symmetry and peak distance at maximal deformation. The potential of the technique is demonstrated and compared to air-puff imaging with Scheimpflug. Measurements ex vivo were performed on 14 freshly enucleated porcine eyes and five human donor eyes. Measurements in vivo were performed on nine human eyes. Corneal deformation was studied as a function of Intraocular Pressure (IOP, 15-45 mmHg), dehydration, changes in corneal rigidity (produced by UV corneal cross-linking, CXL), and different boundary conditions (sclera, ocular muscles). Geometrical deformation parameters were used as input for inverse finite element simulation to retrieve the corneal dynamic elastic and viscoelastic parameters. Temporal and spatial deformation profiles were very sensitive to the IOP. CXL produced a significant reduction of the cornea indentation (1.41x), and a change in the temporal symmetry of the corneal deformation profile (1.65x), indicating a change in the viscoelastic properties with treatment. Combining air-puff with dynamic imaging and finite element modeling allows characterizing the corneal biomechanics in-vivo.

  14. Effects of locus coeruleus stimulation on the responses of SI neurons of the rat to controlled natural and electrical stimulation of the skin.

    PubMed

    Snow, P J; Andre, P; Pompeiano, O

    1999-02-01

    1. The effects of microstimulation of the locus coeruleus (LC) region on the spontaneous discharge and the response of SI neurons to natural and electrical stimulation of the skin have been investigated in 26 urethane anesthetized Sprague-Dawley rats. In particular, one or two air puffs, 5-10 msec in duration, 1-2 psi, usually separated by an interval of 40 msec, were applied on the hairy skin of the wrist or the forepaw at the presentation rate of 1/sec. For units unresponsive to air puffs, similar presentation of low intensity electrical stimuli (0.2-5.0 V, 0.2-0.4 msec pulses) were applied through two needles inserted on the most effective area of the skin. Both natural and electrical stimulations of the skin were applied under control conditions, as well as 50 msec after a 250 msec train of 0.3 msec pulses at 40 Hz. 20-30 microA applied stereotaxically to the LC complex through a tungsten microelectrode. 2. Not all cortical units exhibited spontaneous discharge. Most of the units, however, which were spontaneously active, were inhibited by electrical stimulation of the LC complex, while the remaining ones were excited. The sites of stimulation, which included either the LC proper or the locus subcoeruleus, were identified following both anatomical and physiological criteria. 3. SI neurons recorded at sites between 400 and 950 microns below the surface of the cortex, thus being most likely granule cells of layers III and IV, responded to cutaneous stimuli with spikes which occurred with a latency of 20-30 msec in response to single air puffs and a latency of 15-20 msec in response to single electrical pulses to the skin. In both instances the response to the second stimulus applied at the interstimulus interval of 40 msec was markedly reduced or abolished due to postexcitatory inhibition following the response to the first stimulus (in-field inhibition). In contrast, units particularly located at or below 1000 microns from the cortical surface, which were of very large size probably corresponding to large layer V pyramidal cells, were often difficult to activate with air puffs applied at the centre of the receptive field (RF) and were submitted to electrical stimulation of the skin. 4. Among the 59 isolated SI units tested either to air puffs (45 neurons) or to electrical skin stimulation (14 neurons), 15 units (i.e., 25.4%) were facilitated, while 12 units (i.e., 20.3%) were inhibited following stimulation of the LC complex. 5. A marked feature of the facilitatory effects which usually involved the predominant response to the first air puff, but also the smaller response to the second puff, was that the increase in the number of spikes per stimulus was accompanied by a temporal focusing of the responses characterized by a clear tightening of the latency and narrowing of the peak of activity, which was often accompanied by some level of tonic inhibition of the background discharge. Thus, LC stimulation increased the signal-to-noise ratio of SI neuronal responses to skin stimulation. When inhibitory effects were induced by LC stimulation, they clearly affected the unit response to the first air puff, which was severely depressed. However, the response to the second puff could be facilitated, suggesting that LC stimulation might have produced inhibition of those inhibitory interneurons responsible for the postexcitatory inhibition of the units under examination. Evidence for spatial focusing of the response was not easily documented. In some units, however, LC stimulation produced either facilitation of the responses to puffs at the receptive field center and inhibition of the responses to puffs at the edge at the receptive field or vice versa. 6. Since the LC complex contains in the rat a predominant population of noradrenergic neurons, it is likely that the effects described above were mainly due to activation of these noradrenergic neurons. 7. (ABSTRACT TRUNCATED)

  15. Flame Structure and Emissions of Strongly-Pulsed Turbulent Diffusion Flames with Swirl

    NASA Astrophysics Data System (ADS)

    Liao, Ying-Hao

    This work studies the turbulent flame structure, the reaction-zone structure and the exhaust emissions of strongly-pulsed, non-premixed flames with co-flow swirl. The fuel injection is controlled by strongly-pulsing the fuel flow by a fast-response solenoid valve such that the fuel flow is completely shut off between pulses. This control strategy allows the fuel injection to be controlled over a wide range of operating conditions, allowing the flame structure to range from isolated fully-modulated puffs to interacting puffs to steady flames. The swirl level is controlled by varying the ratio of the volumetric flow rate of the tangential air to that of the axial air. For strongly-pulsed flames, both with and without swirl, the flame geometry is strongly impacted by the injection time. Flames appear to exhibit compact, puff-like structures for short injection times, while elongated flames, similar in behaviors to steady flames, occur for long injection times. The flames with swirl are found to be shorter for the same fuel injection conditions. The separation/interaction level between flame puffs in these flames is essentially governed by the jet-off time. The separation between flame puffs decreases as swirl is imposed, consistent with the decrease in flame puff celerity due to swirl. The decreased flame length and flame puff celerity are consistent with an increased rate of air entrainment due to swirl. The highest levels of CO emissions are generally found for compact, isolated flame puffs, consistent with the rapid quenching due to rapid dilution with excess air. The imposition of swirl generally results in a decrease in CO levels, suggesting more rapid and complete fuel/air mixing by imposing swirl in the co-flow stream. The levels of NO emissions for most cases are generally below the steady-flame value. The NO levels become comparable to the steady-flame value for sufficiently short jet-off time. The swirled co-flow air can, in some cases, increase the NO emissions. The elevated NO emissions are due to a longer combustion residence time due to the flow recirculation within the swirl-induced recirculation zone. The reaction zone structure, based on OH planar laser-induced fluorescence (PLIF) is broadly consistent with the observation of luminous flame structure for these types of flames. In many cases, the reaction zone exhibits discontinuities at the instantaneous flame tip in the early period of fuel injection. These discontinuities in the reaction zone likely result from the non-ignition of injected fuel, due to a relatively slower reaction rate in comparison with the mixing rate. The discontinuity in the OH zone is generally seen to diminish with increased swirl level. Statistics generated from the OH PLIF signals show that the reaction zone area generally increases with increased swirl level, consistent with a broader and more convoluted OH-zone structure for flames with swirl. The reaction zone area for swirled flames generally exhibits a higher degree of fluctuation, suggesting a relatively stronger impact of flow turbulence on the flame structure for flames with swirl.

  16. Video-Puff of Air Hits Ball of Water in Space Onboard the International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    2003-01-01

    Saturday Morning Science, the science of opportunity series of applied experiments and demonstrations, performed aboard the International Space Station (ISS) by Expedition 6 astronaut Dr. Don Pettit, revealed some remarkable findings. In this video clip, Dr. Pettit demonstrates the phenomenon of a puff of air hitting a ball of water that is free floating in space. Watch the video to see why Dr. Pettit remarks 'I'd hate think that our planet would go through these kinds of gyrations if it got whacked by a big asteroid'.

  17. Modeling smoke plume patterns in drainage flows

    Treesearch

    M.A. Fosberg

    1985-01-01

    A three-dimensional diagnostic wind model for use in complex terrain has been combined with a three-dimensional trajectory and puff air quality model. The wind model utilizes a terrain following coordinate system and conserves both mass and momentum. The wind model provides the winds required by the predictive trajectory and puff dispersion model. Both the wind model...

  18. CO exposure, puff topography, and subjective effects in waterpipe tobacco smokers

    PubMed Central

    Maziak, Wasim; Rastam, Samer; Ibrahim, Iman; Ward, Kenneth D.; Shihadeh, Alan

    2009-01-01

    Introduction: Waterpipe tobacco smoking is increasing in popularity though the toxicant exposure and effects associated with this tobacco use method are not well understood. Methods: Sixty-one waterpipe tobacco smokers (56 males; mean age ± SD, 30.9 ± 9.5 years; mean number of weekly waterpipe smoking episodes, 7.8 ± 5.7; mean duration of waterpipe smoking 8.5 ± 6.1 years) abstained from smoking for at least 24 hr and then smoked tobacco from a waterpipe ad libitum in a laboratory. Before and after smoking, expired-air carbon monoxide (CO) and subjective effects were assessed; puff topography was measured during smoking. Results: The mean waterpipe use episode duration was 33.1 ± 13.1 min. Expired-air CO increased significantly from a mean of 4.0 ± 1.7 before to 35.5 ± 32.7 after smoking. On average, participants took 169 ± 100 puffs, with a mean puff volume of 511 ± 333 ml. Urge to smoke, restlessness, craving, and other tobacco abstinence symptoms were reduced significantly after smoking, while ratings of dizzy, lightheaded, and other direct effects of nicotine increased. Discussion: Expired-air CO and puff topography data indicate that, relative to a single cigarette, a single waterpipe tobacco smoking episode is associated with greater smoke exposure. Abstinent waterpipe tobacco smokers report symptoms similar to those reported by abstinent cigarette smokers, and these symptoms are reduced by subsequent waterpipe tobacco smoking. Taken together, these data are consistent with the notion that waterpipe tobacco smoking is likely associated with the risk of tobacco/nicotine dependence. PMID:19420278

  19. Pulmonary Function in Flight (PuFF) Experiment

    NASA Technical Reports Server (NTRS)

    2003-01-01

    In this International Space Station (ISS) onboard photo, Expedition Six Science Officer Donald R. Pettit works to set up the Pulmonary Function in Flight (PuFF) experiment hardware in the Destiny Laboratory. Expedition Six is the fourth and final crew to perform the PuFF experiment. The PuFF experiment was developed to better understand what effects long term exposure to microgravity may have on the lungs. The focus is on measuring changes in the everness of gas exchange in the lungs, and on detecting changes in respiratory muscle strength. It allows astronauts to measure blood flow through the lungs, the ability of the lung to take up oxygen, and lung volumes. Each PuFF session includes five lung function tests, which involve breathing only cabin air. For each planned extravehicular (EVA) activity, a crew member performs a PuFF test within one week prior to the EVA. Following the EVA, those crew members perform another test to document the effect of exposure of the lungs to the low-pressure environment of the space suits. This experiment utilizes the Gas Analyzer System for Metabolic Analysis Physiology, or GASMAP, located in the Human Research Facility (HRF), along with a variety of other Puff equipment including a manual breathing valve, flow meter, pressure-flow module, pressure and volume calibration syringes, and disposable mouth pieces.

  20. Behavior of accessory abducens and abducens motoneurons during eye retraction and rotation in the alert cat.

    PubMed

    Delgado-Garcia, J M; Evinger, C; Escudero, M; Baker, R

    1990-08-01

    1. The activity of both accessory abducens (Acc Abd) and abducens (Abd) motoneurons (Mns) was recorded in the alert cat during eye retraction and rotational eye movements. Cats were fitted with two scleral coils, one measured rotational eye movements directly and the other retraction by distinguishing the translational component. 2. Acc Abd and Abd Mns were identified following antidromic activation from electrical stimulation of the ipsilateral VIth nerve. 3. In response to corneal air puffs, bursts of spikes were produced in all (n = 30) Acc Abd Mns. The burst began 7.2 +/- 1.2 (SD) ms after onset of the air puff and 8.9 +/- 1.9 ms before eye retraction. 4. Acc Abd Mns were silent throughout all types of rotational eye movements, and tonic activity was not observed during intervals without air-puff stimulation. 5. In contrast, all (n = 50) identified Abd Mns exhibited a burst and/or pause in activity preceding and during horizontal saccades as well as a tonic activity proportional to eye position. 6. Only 10% of Abd Mns fired a weak burst of spikes in response to air-puff stimulation. 7. We conclude that Acc Abd Mns are exclusively involved in eye retraction in the cat and that only a few Abd Mns have an eye-retraction signal added to their eye position and velocity signals. Thus any rotational eye-movement response described in retractor bulbi muscle must result from innervation by Mns located in the Abd and/or the oculomotor nuclei. 8. The organization of the prenuclear circuitry and species variation are discussed in view of the nictiating membrane extension response measured in associative learning.

  1. Integration of plume and puff diffusion models/application of CFD

    NASA Astrophysics Data System (ADS)

    Mori, Akira

    The clinical symptoms of patients and other evidences of a gas poisoning accident inside an industrial building strongly suggested an abrupt influx of engine exhaust from a construction vehicle which was operating outside in the open air. But the obviously high level of gas concentration could not be well explained by any conventional steady-state gas diffusion models. The author used an unsteady-state continuous Puff Model to simulate the time-wise changes in air stream with the pollutant gas being continuously emitted, and successfully reproduced the observed phenomena. The author demonstrates that this diffusion formula can be solved analytically by the use of error function as long as the change in wind velocity is stepwise, and clarifies the accurate differences between the unsteady- and steady-states and their convergence profiles. Also, the relationship between the Puff and Plume Models is discussed. The case study included a computational fluid dynamics (CFD) analysis to estimate the steady-state air stream and the gas concentration pattern in the affected area. It is well known that clear definition of the boundary conditions is key to successful CFD analysis. The author describes a two-step use of CFD: the first step to define the boundary conditions and the second to determine the steady-state air stream and the gas concentration pattern.

  2. International Space Station (ISS)

    NASA Image and Video Library

    2003-01-16

    In this International Space Station (ISS) onboard photo, Expedition Six Science Officer Donald R. Pettit works to set up the Pulmonary Function in Flight (PuFF) experiment hardware in the Destiny Laboratory. Expedition Six is the fourth and final crew to perform the PuFF experiment. The PuFF experiment was developed to better understand what effects long term exposure to microgravity may have on the lungs. The focus is on measuring changes in the everness of gas exchange in the lungs, and on detecting changes in respiratory muscle strength. It allows astronauts to measure blood flow through the lungs, the ability of the lung to take up oxygen, and lung volumes. Each PuFF session includes five lung function tests, which involve breathing only cabin air. For each planned extravehicular (EVA) activity, a crew member performs a PuFF test within one week prior to the EVA. Following the EVA, those crew members perform another test to document the effect of exposure of the lungs to the low-pressure environment of the space suits. This experiment utilizes the Gas Analyzer System for Metabolic Analysis Physiology, or GASMAP, located in the Human Research Facility (HRF), along with a variety of other Puff equipment including a manual breathing valve, flow meter, pressure-flow module, pressure and volume calibration syringes, and disposable mouth pieces.

  3. Development, validation and application of a device to measure e-cigarette users’ puffing topography

    PubMed Central

    Cunningham, Anthony; Slayford, Sandra; Vas, Carl; Gee, Jodie; Costigan, Sandra; Prasad, Krishna

    2016-01-01

    With the rapidly rising popularity and substantial evolution of electronic cigarettes (e-cigarettes) in the past 5–6 years, how these devices are used by vapers and consumers’ exposure to aerosol emissions need to be understood. We used puffing topography to measure directly product use. We adapted a cigarette puffing topography device for use with e-cigarettes. We performed validation using air and e-cigarette aerosol under multiple regimes. Consumer puffing topography was measured for 60 vapers provided with rechargeable “cig-a-like” or larger button-activated e-cigarettes, to use ad-libitum in two sessions. Under all regimes, air puff volumes were within 1 mL of the target and aerosol volumes within 5 mL for all device types, serving to validate the device. Vapers’ mean puff durations (2.0 s and 2.2 s) were similar with both types of e-cigarette, but mean puff volumes (52.2 mL and 83.0 mL) and mean inter-puff intervals (23.2 s and 29.3 s) differed significantly. The differing data show that product characteristics influence puffing topography and, therefore, the results obtained from a given e-cigarette might not read across to other products. Understanding the factors that affect puffing topography will be important for standardising testing protocols for e-cigarette emissions. PMID:27721496

  4. Fully Modulated Turbulent Diffusion Flames in Microgravity*

    NASA Astrophysics Data System (ADS)

    Sangras, Ravikiran; Hermanson, James C.; Johari, Hamid; Stocker, Dennis P.; Hegde, Uday G.

    2001-11-01

    Fully modulated, turbulent diffusion flames are studied in microgravity in 2.2 s drop-tower tests with a co-flow combustor. The fuel consists of pure ethylene or a 50/50 mixture with nitrogen; the oxidizer is either normal air or up to 40% oxygen in nitrogen. A fast solenoid valve is used to fully modulate (completely shut off) the fuel flow. The injection times range from 5 to 400 ms with a duty-cycle of 0.1 - 0.5. The fuel nozzle is 2 mm in diameter with a jet Reynolds number of 5000. The shortest injection times yield compact puffs with a mean flame length as little as 20% of that of the steady-state flame. The reduction in flame length appears to be somewhat greater in microgravity than in normal gravity. As the injection time increases, elongated flames result with a mean flame length comparable to that of a steady flame. The injection time for which the steady-state flame length is approached is shorter for lower air/fuel ratios. For a given duty-cycle, the separation between puffs is greater in microgravity than in normal gravity. For compact puffs, increasing the duty-cycle appears to increase the flame length more in microgravity than in normal gravity. The microgravity flame puffs do not exhibit the vortex-ring-like structure seen in normal gravity.

  5. Development, validation and application of a device to measure e-cigarette users' puffing topography.

    PubMed

    Cunningham, Anthony; Slayford, Sandra; Vas, Carl; Gee, Jodie; Costigan, Sandra; Prasad, Krishna

    2016-10-10

    With the rapidly rising popularity and substantial evolution of electronic cigarettes (e-cigarettes) in the past 5-6 years, how these devices are used by vapers and consumers' exposure to aerosol emissions need to be understood. We used puffing topography to measure directly product use. We adapted a cigarette puffing topography device for use with e-cigarettes. We performed validation using air and e-cigarette aerosol under multiple regimes. Consumer puffing topography was measured for 60 vapers provided with rechargeable "cig-a-like" or larger button-activated e-cigarettes, to use ad-libitum in two sessions. Under all regimes, air puff volumes were within 1 mL of the target and aerosol volumes within 5 mL for all device types, serving to validate the device. Vapers' mean puff durations (2.0 s and 2.2 s) were similar with both types of e-cigarette, but mean puff volumes (52.2 mL and 83.0 mL) and mean inter-puff intervals (23.2 s and 29.3 s) differed significantly. The differing data show that product characteristics influence puffing topography and, therefore, the results obtained from a given e-cigarette might not read across to other products. Understanding the factors that affect puffing topography will be important for standardising testing protocols for e-cigarette emissions.

  6. Turbulent structure and emissions of strongly-pulsed jet diffusion flames

    NASA Astrophysics Data System (ADS)

    Fregeau, Mathieu

    This current research project studied the turbulent flame structure, the fuel/air mixing, the combustion characteristics of a nonpremixed pulsed (unsteady) and unpulsed (steady) flame configuration for both normal- and microgravity conditions, as well as the flame emissions in normal gravity. The unsteady flames were fully-modulated, with the fuel flow completely shut off between injection pulses using an externally controlled valve, resulting in the generation of compact puff-like flame structures. Conducting experiments in normal and microgravity environments enabled separate control over the relevant Richardson and Reynolds numbers to clarify the influence of buoyancy on the flame behavior, mixing, and structure. Experiments were performed in normal gravity in the laboratory at the University of Washington and in microgravity using the NASA GRC 2.2-second Drop Tower facility. High-speed imaging, as well as temperature and emissions probes were used to determine the large-scale structure dynamics, the details of the flame structure and oxidizer entrainment, the combustion temperatures, and the exhaust emissions of the pulsed and steady flames. Of particular interest was the impact of changes in flame structure due to pulsing on the combustion characteristics of this system. The turbulent flame puff celerity (i.e., the bulk velocity of the puffs) was strongly impacted by the jet-off time, increasing markedly as the time between pulses was decreased, which caused the degree of puff interaction to increase and the strongly-pulsed flame to more closely resemble a steady flame. This increase occurred for all values of injection time as well as for constant fuelling rate and in both the presence and absence of buoyancy. The removal of positive buoyancy in microgravity resulted in a decrease in the flame puff celerity in all cases, amounting to as much as 40%, for both constant jet injection velocity and constant fuelling rate. The mean flame length of the strongly-pulsed flames was not strongly impacted by buoyancy. This lack of sensitivity to buoyancy was consistent with offsetting changes in flame puff celerity and time to burnout for the microgravity versus normal-gravity cases. The emissions of CO and NO were examined in the vicinity of the visible flame tip and at the combustor exit for strongly-pulsed flames. The highest exhaust-point emission indices of CO for compact, isolated puffs were as much as a factor of six higher than those of elongated flames with longer injection times. The amount of CO decreased substantially with a decreased amount of flame puff interaction. The higher CO levels for pulsed flames with the shortest injection times were consistent with quenching due to the very rapid mixing and dilution with excess air for the most compact flame puffs. The injection time for which steady-flame emission levels were attained was comparable to the injection time for which the visible flame length approached the flame length of steady flames. The CO emissions, for a given fuelling rate, were strongly dependent on both the injection time and jet-off time for a jet-on fraction less than approximately 50%. The NO levels were generally proportional to the fuelling rate. This work indicates that there are specific combinations of injection time and jet-off time that considerably change the fuel/air mixing, resulting in emissions comparable to those of the steady flame while the flame length is significantly shorter. This points the potential utility of the strongly-pulsed injection technique in the development of compact, low emissions combustors involving turbulent diffusion flames. (Abstract shortened by UMI.)

  7. On The Development of One-way Nesting of Air-pollution Model Smog Into Numerical Weather Prediction Model Eta

    NASA Astrophysics Data System (ADS)

    Halenka, T.; Bednar, J.; Brechler, J.

    The spatial distribution of air pollution on the regional scale (Bohemian region) is simulated by means of Charles University puff model SMOG. The results are used for the assessment of the concentration fields of ozone, nitrogen oxides and other ozone precursors. Current improved version of the model covers up to 16 groups of basic compounds and it is based on trajectory computation and puff interaction both by means of Gaussian diffusion mixing and chemical reactions of basic species. Gener- ally, the method used for trajectory computation is valuable mainly for episodes sim- ulation, nevertheless, climatological study can be solved as well by means of average wind rose. For the study being presented huge database of real emission sources was incorporated with all kind of sources included. Some problem with the background values of concentrations was removed. The model SMOG has been nested into the forecast model ETA to obtain appropriate meteorological data input. We can estimate air pollution characteristics both for episodes analysis and the prediction of future air quality conditions. Necessary prognostic variables from the numerical weather pre- diction model are taken for the region of the central Bohemia, where the original puff model was tested. We used mainly 850 hPa wind field for computation of prognos- tic trajectories, the influence of surface temperature as a parameter of photochemistry reactions as well as the effect of cloudness has been tested.

  8. No Evidence for Emotional Empathy in Chickens Observing Familiar Adult Conspecifics

    PubMed Central

    Edgar, Joanne L.; Paul, Elizabeth S.; Harris, Lauren; Penturn, Sarah; Nicol, Christine J.

    2012-01-01

    The capacity of animals to empathise is of high potential relevance to the welfare of group-housed domestic animals. Emotional empathy is a multifaceted and multilayered phenomenon which ranges from relatively simple processes such as emotional matching behaviour to more complex processes involving interaction between emotional and cognitive perspective taking systems. Our previous research has demonstrated that hens show clear behavioural and physiological responses to the mild distress of their chicks. To investigate whether this capacity exists outside the mother/offspring bond, we conducted a similar experiment in which domestic hens were exposed to the mild distress of unrelated, but familiar adult conspecifics. Each observer hen was exposed to two replicates of four conditions, in counterbalanced order; control (C); control with noise of air puff (CN); air puff to conspecific hen (APC); air puff to observer hen (APH). During each test, the observer hens' behaviour and physiology were measured throughout a 10 min pre-treatment and a 10 min treatment period. Despite showing signs of distress in response to an aversive stimulus directed at themselves (APH), and using methodology sufficiently sensitive to detect empathy-like responses previously, observer hens showed no behavioural or physiological responses to the mild distress of a familiar adult conspecific. The lack of behavioural and physiological response indicates that hens show no basis for emotional empathy in this context. PMID:22348100

  9. Buoyancy Effects in Strongly-Pulsed, Turbulent Diffusion Flames

    NASA Astrophysics Data System (ADS)

    Hermanson, James; Johari, Hamid; Stocker, Dennis; Hegde, Uday

    2004-11-01

    Buoyancy effects in pulsed, turbulent flames are studied in microgravity in a 2.2 s drop-tower. The fuel is pure ethylene or a 50/50 mixture with nitrogen; the oxidizer co-flow is either air or 30% oxygen in nitrogen. A fast solenoid valve fully modulates (shuts off) the fuel flow between pulses. The jet Reynolds number is 5000 with a nozzle i.d. of 2 mm. For short injection times and small duty cycle (jet-on fraction), compact, puff-like flames occur. The invariance in flame length of these puffs with buoyancy is due to offsetting changes in puff celerity and burnout time. Buoyancy does impact interacting flame puffs, with the flame length generally increasing with injection duty cycle. The mean centerline temperatures for all flames are generally higher in microgravity than in normal gravity. The transition in temperatures with increasing injection time is more gradual in micro-g than in 1-g. These observations can be explained in terms of the local duty cycle in the flame and differences in entrainment in normal- vs. microgravity.

  10. Noncontact measurement of elasticity for the detection of soft-tissue tumors using phase-sensitive optical coherence tomography combined with a focused air-puff system.

    PubMed

    Wang, Shang; Li, Jiasong; Manapuram, Ravi Kiran; Menodiado, Floredes M; Ingram, Davis R; Twa, Michael D; Lazar, Alexander J; Lev, Dina C; Pollock, Raphael E; Larin, Kirill V

    2012-12-15

    We report on an optical noncontact method for the detection of soft-tissue tumors based on the measurement of their elasticity. A focused air-puff system is used to excite surface waves (SWs) on soft tissues with transient static pressure. A high-speed phase-sensitive optical coherence tomography system is used to measure the SWs as they propagate from the point of excitation. To evaluate the stiffness of soft tissues, the Young's modulus is quantified based on the group velocity of SWs. Pilot experiments were performed on ex vivo human myxoma and normal fat. Results demonstrate the feasibility of the proposed method to measure elasticity and differentiate soft-tissue tumors from normal tissues.

  11. Pulsed Turbulent Diffusion Flames in a Coflow

    NASA Astrophysics Data System (ADS)

    Usowicz, James E.; Hermanson, James C.; Johari, Hamid

    2000-11-01

    Fully modulated diffusion flames were studied experimentally in a co-flow combustor using unheated ethylene fuel at atmospheric pressure. A fast solenoid valve was used to fully modulate (completely shut-off) the fuel flow. The fuel was released from a 2 mm diameter nozzle with injection times ranging from 2 to 750 ms. The jet exit Reynolds number was 2000 to 10,000 with a co-flow air velocity of up to 0.02 times the jet exit velocity. Establishing the effects of co-flow for the small nozzle and short injection times is required for future tests of pulsed flames under microgravity conditions. The very short injection times resulted in compact, burning puffs. The compact puffs had a mean flame length as little as 20flame for the same Reynolds number. As the injection time and fuel volume increased, elongated flames resembling starting jets resulted with a flame length comparable to that of a steady flame. For short injection times, the addition of an air co-flow resulted in an increase in flame length of nearly 50flames with longer injection times was correspondingly smaller. The effects of interaction of successive pulses on the flame length were most pronounced for the compact puffs. The emissions of unburned hydrocarbon and NOx from the pulsed flames were examined.

  12. DEVELOPMENT OF MESOSCALE AIR QUALITY SIMULATION MODELS. VOLUME 1. COMPARATIVE SENSITIVITY STUDIES OF PUFF, PLUME, AND GRID MODELS FOR LONG DISTANCE DISPERSION

    EPA Science Inventory

    This report provides detailed comparisons and sensitivity analyses of three candidate models, MESOPLUME, MESOPUFF, and MESOGRID. This was not a validation study; there was no suitable regional air quality data base for the Four Corners area. Rather, the models have been evaluated...

  13. Should Orbscan pachometry be performed before or after Goldmann applanation tonometry?

    PubMed

    Huang, Ronnie Y C; Lam, Andrew K C; Chan, Rufina; Young, Shui-Ming

    2005-09-01

    To compare the Orbscan central corneal thickness (CCT) values before and after intraocular pressure (IOP) measurement with Goldmann applanation tonometry in young normal adults. Fifty-three eyes of 53 subjects who were free from any ocular problems were studied. The measurements included optical pachometry by the Orbscan II system, followed by Goldmann applanation tonometry, and finally Orbscan optical pachometry again. Standard Goldmann technique was adopted with the application of one drop of 0.4% benoxinate and fluorescein sodium prior to the measurement. The same operator was involved in the Orbscan pachometry before and after Goldmann tonometry. Another investigator was responsible for Goldmann tonometry. Three readings were obtained in each case, and the means were used for analysis. The mean IOP of the sample was 14.6 +/- 2.6 mmHg. There was no significant difference (paired t-test: p = 0.50) in the mean CCT values before and after the Goldmann tonometry (551 +/- 32 and 552 +/- 35 microm respectively). Standard Goldmann applanation tonometry does not affect the Orbscan CCT values. Measurement of CCT for the adjustment of true IOP can be carried out either before or after Goldmann tonometry.

  14. Auditory modulation of wind-elicited walking behavior in the cricket Gryllus bimaculatus.

    PubMed

    Fukutomi, Matasaburo; Someya, Makoto; Ogawa, Hiroto

    2015-12-01

    Animals flexibly change their locomotion triggered by an identical stimulus depending on the environmental context and behavioral state. This indicates that additional sensory inputs in different modality from the stimulus triggering the escape response affect the neuronal circuit governing that behavior. However, how the spatio-temporal relationships between these two stimuli effect a behavioral change remains unknown. We studied this question, using crickets, which respond to a short air-puff by oriented walking activity mediated by the cercal sensory system. In addition, an acoustic stimulus, such as conspecific 'song' received by the tympanal organ, elicits a distinct oriented locomotion termed phonotaxis. In this study, we examined the cross-modal effects on wind-elicited walking when an acoustic stimulus was preceded by an air-puff and tested whether the auditory modulation depends on the coincidence of the direction of both stimuli. A preceding 10 kHz pure tone biased the wind-elicited walking in a backward direction and elevated a threshold of the wind-elicited response, whereas other movement parameters, including turn angle, reaction time, walking speed and distance were unaffected. The auditory modulations, however, did not depend on the coincidence of the stimulus directions. A preceding sound consistently altered the wind-elicited walking direction and response probability throughout the experimental sessions, meaning that the auditory modulation did not result from previous experience or associative learning. These results suggest that the cricket nervous system is able to integrate auditory and air-puff stimuli, and modulate the wind-elicited escape behavior depending on the acoustic context. © 2015. Published by The Company of Biologists Ltd.

  15. Correction on the distortion of Scheimpflug imaging for dynamic central corneal thickness

    NASA Astrophysics Data System (ADS)

    Li, Tianjie; Tian, Lei; Wang, Like; Hon, Ying; Lam, Andrew K. C.; Huang, Yifei; Wang, Yuanyuan; Zheng, Yongping

    2015-05-01

    The measurement of central corneal thickness (CCT) is important in ophthalmology. Most studies concerned the value at normal status, while rare ones focused on its dynamic changing. The commercial Corvis ST is the only commercial device currently available to visualize the two-dimensional image of dynamic corneal profiles during an air puff indentation. However, the directly observed CCT involves the Scheimpflug distortion, thus misleading the clinical diagnosis. This study aimed to correct the distortion for better measuring the dynamic CCTs. The optical path was first derived to consider the influence of factors on the use of Covis ST. A correction method was then proposed to estimate the CCT at any time during air puff indentation. Simulation results demonstrated the feasibility of the intuitive-feasible calibration for measuring the stationary CCT and indicated the necessity of correction when air puffed. Experiments on three contact lenses and four human corneas verified the prediction that the CCT would be underestimated when the improper calibration was conducted for air and overestimated when it was conducted on contact lenses made of polymethylmethacrylate. Using the proposed method, the CCT was finally observed to increase by 66±34 μm at highest concavity in 48 normal human corneas.

  16. Landing of the Shuttle Discovery at the end of the STS 51-D mission

    NASA Technical Reports Server (NTRS)

    1985-01-01

    A side looking, wide view of the Shuttle Discovery shows the vehicle on its final approach to the Kennedy Space Center (KSC) landing site (9107); Discovery's nose wheels touch down at the KSC landing site (9108); Discovery's main landing gear touches down, throwing puffs of dirt in the air. The orbiter's nose wheels are still in the air (9109).

  17. Dispersion Modeling Using Ensemble Forecasts Compared to ETEX Measurements.

    NASA Astrophysics Data System (ADS)

    Straume, Anne Grete; N'dri Koffi, Ernest; Nodop, Katrin

    1998-11-01

    Numerous numerical models are developed to predict long-range transport of hazardous air pollution in connection with accidental releases. When evaluating and improving such a model, it is important to detect uncertainties connected to the meteorological input data. A Lagrangian dispersion model, the Severe Nuclear Accident Program, is used here to investigate the effect of errors in the meteorological input data due to analysis error. An ensemble forecast, produced at the European Centre for Medium-Range Weather Forecasts, is then used as model input. The ensemble forecast members are generated by perturbing the initial meteorological fields of the weather forecast. The perturbations are calculated from singular vectors meant to represent possible forecast developments generated by instabilities in the atmospheric flow during the early part of the forecast. The instabilities are generated by errors in the analyzed fields. Puff predictions from the dispersion model, using ensemble forecast input, are compared, and a large spread in the predicted puff evolutions is found. This shows that the quality of the meteorological input data is important for the success of the dispersion model. In order to evaluate the dispersion model, the calculations are compared with measurements from the European Tracer Experiment. The model manages to predict the measured puff evolution concerning shape and time of arrival to a fairly high extent, up to 60 h after the start of the release. The modeled puff is still too narrow in the advection direction.

  18. Effect of smoking parameters on the particle size distribution and predicted airway deposition of mainstream cigarette smoke.

    PubMed

    Kane, David B; Asgharian, Bahman; Price, Owen T; Rostami, Ali; Oldham, Michael J

    2010-02-01

    It is known that puffing conditions such as puff volume, duration, and frequency vary substantially among individual smokers. This study investigates how these parameters affect the particle size distribution and concentration of fresh mainstream cigarette smoke (MCS) and how these changes affect the predicted deposition of MCS particles in a model human respiratory tract. Measurements of the particle size distribution made with an electrical low pressure impactor for a variety of puffing conditions are presented. The average flow rate of the puff is found to be the major factor effecting the measured particle size distribution of the MCS. The results of these measurements were then used as input to a deterministic dosimetry model (MPPD) to estimate the changes in the respiratory tract deposition fraction of smoke particles. The MPPD dosimetry model was modified by incorporating mechanisms involved in respiratory tract deposition of MCS: hygroscopic growth, coagulation, evaporation of semivolatiles, and mixing of the smoke with inhaled dilution air. The addition of these mechanisms to MPPD resulted in reasonable agreement between predicted airway deposition and human smoke retention measurements. The modified MPPD model predicts a modest 10% drop in the total deposition efficiency in a model human respiratory tract as the puff flow rate is increased from 1050 to 3100 ml/min, for a 2-s puff.

  19. Behavioral analyses of wind-evoked escape of the cricket, Gryllodes sigillatus.

    PubMed

    Kanou, Masamichi; Konishi, Atsuko; Suenaga, Rie

    2006-04-01

    The wind-evoked escape behavior of the cricket Gryllodes sigillatus was investigated using an air puff stimulus. A high velocity air puff elicited the escape behavior in many crickets. The crickets tended to escape away from the stimulus source, but the direction was not accurately oriented 180 degrees from the stimulus. After bilateral cercal ablation, only a few crickets showed wind-evoked escape behavior, and their response rates did not increase even 19 days after ablation. Therefore, information on air motion detected by cercal filiform hairs is essential for triggering wind-evoked behavior. After unilateral cercal ablation, the 81.3% response rate of intact crickets decreased to 16.5%, that is, it decreased to almost 20% that of intact crickets. One week after unilateral cercal ablation, the response rate recovered to more than 60% that of intact crickets. However, the accuracy rate of the escape direction of G. sigillatus showed no change even immediately after the unilateral cercal ablation. Therefore, both cerci are not necessarily required to determine the escape direction. The behavioral characteristics of wind-evoked escape of G. sigillatus are compared with those of another species of cricket, Gryllus bimaculatus. The two species of cricket employ different strategies for wind-evoked escape.

  20. SIMULATION OF A REACTING POLLUTANT PUFF USING AN ADAPTIVE GRID ALGORITHM

    EPA Science Inventory

    A new dynamic solution adaptive grid algorithm DSAGA-PPM, has been developed for use in air quality modeling. In this paper, this algorithm is described and evaluated with a test problem. Cone-shaped distributions of various chemical species undergoing chemical reactions are rota...

  1. Puffing Topography and Nicotine Intake of Electronic Cigarette Users

    PubMed Central

    Behar, Rachel Z.; Hua, My; Talbot, Prue

    2015-01-01

    Background Prior electronic cigarette (EC) topography data are based on two video analyses with limited parameters. Alternate methods for measuring topography are needed to understand EC use and nicotine intake. Objectives This study evaluated EC topography with a CReSS Pocket device and quantified nicotine intake. Methods Validation tests on pressure drop, flow rate, and volume confirmed reliable performance of the CReSS Pocket device. Twenty participants used Blu Cigs and V2 Cigs for 10 minute intervals with a 10–15 minute break between brands. Brand order was reversed and repeated within 7 days Data were analyzed to determine puff duration, puff count, volume, flow rate, peak flow, and inter-puff interval. Nicotine intake was estimated from cartomizer fluid consumption and topography data. Results Nine patterns of EC use were identified. The average puff count and inter-puff interval were 32 puffs and 17.9 seconds. All participants, except one, took more than 20 puffs/10 minutes. The averages for puff duration (2.65 seconds/puff), volume/puff (51ml/puff), total puff volume (1,579 ml), EC fluid consumption (79.6 mg), flow rate (20 ml/s), and peak flow rate (27 ml/s) were determined for 10-minute sessions. All parameters except total puff count were significantly different for Blu versus V2 EC. Total volume for Blu versus V2 was four-times higher than for conventional cigarettes. Average nicotine intake for Blu and V2 across both sessions was 1.2 ± 0.5 mg and 1.4 ± 0.7 mg, respectively, which is similar to conventional smokers. Conclusions EC puffing topography was variable among participants in the study, but often similar within an individual between brands or days. Puff duration, inter-puff interval, and puff volume varied from conventional cigarette standards. Data on total puff volume and nicotine intake are consistent with compensatory usage of EC. These data can contribute to the development of a standard protocol for laboratory testing of EC products. PMID:25664463

  2. Suppressing effect of C a2 + blips on puff amplitudes by inhibiting channels to prevent recovery

    NASA Astrophysics Data System (ADS)

    Chen, Yuan; Qi, Hong; Li, Xiang; Cai, Meichun; Chen, Xingqiang; Liu, Wen; Shuai, Jianwei

    2016-08-01

    As local signals, calcium puffs arise from the concerted opening of a few nearby inositol 1,4,5-trisphospate receptor channels to release C a2 + ions from the endoplasmic reticulum. Although C a2 + puffs have been well studied, little is known about the modulation of cytosolic basal C a2 + concentration ([Ca2 +] Basal) on puff dynamics. In this paper we consider a puff model to study how the statistical properties of puffs are modulated by [Ca2 +] Basal. The puff frequency and lifetime trivially increase with the increasing [Ca2 +] Basal, but an unexpected result is that the puff amplitude and the maximum open-channel number of the puff show decreasing relationship with the increasing [Ca2 +] Basal. The underlying dynamics is related not only to the increasing puff frequency which gives a shorter recovery time, but also to the increasing frequency of blips with only one channel open. We indicate that C a2 + blips cause the channels to be inhibited and prevent their recovery during interpuff intervals, resulting in the suppressing effect on puff amplitudes. With increasing [Ca2 +] Basal, more blips occur to cause more channels to be inhibited, leaving fewer channels available for puff events. This study shows that the blips may play relevant functions in global C a2 + waves through modulating puff dynamics.

  3. Predicting air quality near roadways through the application of a Gaussian Puff Model to moving sources

    DOT National Transportation Integrated Search

    2000-06-19

    The Environmental Protection Agency (EPA) currently recommends the use of CALINE3 or CAL3QHC for modeling the dispersion of carbon monoxide (CO) near roadways. These models treat vehicles as part of a line source such that the emissions are homogeneo...

  4. A Classical Conditioning Procedure for the Hearing Assessment of Multiply Handicapped Persons.

    ERIC Educational Resources Information Center

    Lancioni, Giulio E.; And Others

    1989-01-01

    Hearing assessments of multiply handicapped children/adolescents were conducted using classical conditioning (with an air puff as unconditioned stimulus) and operant conditioning (with a modified visual reinforcement audiometry procedure or edible reinforcement). Findings indicate that classical conditioning was successful with 21 of the 23…

  5. A Link between Adolescent Nicotine Metabolism and Smoking Topography

    PubMed Central

    Moolchan, Eric T.; Parzynski, Craig S.; Jaszyna-Gasior, Maria; Collins, Charles C.; Leff, Michelle K.; Zimmerman, Debra L.

    2009-01-01

    Adult slow nicotine metabolizers have lower smoke exposure, carbon monoxide levels, and plasma nicotine levels than normal and fast metabolizers. Emerging evidence suggests nicotine metabolism influences smoking topography. This study investigated the association of nicotine metabolism (the ratio of plasma 3-hydroxycotinine to cotinine; 3OHCOT/COT) with smoking topography in adolescent smokers (N=85, 65% female, 68% European American, mean age 15.3 ± 1.2, mean cigarettes per day (CPD) 18.5 ± 8.5, mean Fagerström Test for Nicotine Dependence (FTND) 7.0 ± 1.2) presenting for a nicotine replacement therapy trial. Measures obtained included puff volume, inter-puff interval, number of puffs, puff duration, and puff velocity. Linear regression analysis controlling for hormonal contraception use showed that 3OHCOT/COT ratios predicted mean puff volume in the overall sample (t = 2.126, p = .037, adjusted R2 = .067). After gender stratification, faster metabolism predicted higher mean puff volume (t = 2.81, p = .009, adjusted R2 = .192) but fewer puffs (t = −3.160, p=0.004, adjusted R2 = .237) and lower mean puff duration (t = −2.06, p = .048, adjusted R2 = .101) among boys only, suggesting that as nicotine metabolism increases, puff volume increases but puffing frequency decreases. No significant relationships were found between nicotine metabolism and total puff volume, mean puff duration, inter-puff interval, or puff velocity. If confirmed in a broader sample of adolescent smokers, these findings suggest that, as among dependent adult smokers, rate of metabolism among adolescent boys is linked to select parameters of puffing behavior that may impact cessation ability. PMID:19423535

  6. Variability among electronic cigarettes in the pressure drop, airflow rate, and aerosol production.

    PubMed

    Williams, Monique; Talbot, Prue

    2011-12-01

    This study investigated the performance of electronic cigarettes (e-cigarettes), compared different models within a brand, compared identical copies of the same model within a brand, and examined performance using different protocols. Airflow rate required to generate aerosol, pressure drop across e-cigarettes, and aerosol density were examined using three different protocols. First 10 puff protocol: The airflow rate required to produce aerosol and aerosol density varied among brands, while pressure drop varied among brands and between the same model within a brand. Total air hole area correlated with pressure drop for some brands. Smoke-out protocol: E-cigarettes within a brand generally performed similarly when puffed to exhaustion; however, there was considerable variation between brands in pressure drop, airflow rate required to produce aerosol, and the total number of puffs produced. With this protocol, aerosol density varied significantly between puffs and gradually declined. CONSECUTIVE TRIAL PROTOCOL: Two copies of one model were subjected to 11 puffs in three consecutive trials with breaks between trials. One copy performed similarly in each trial, while the second copy of the same model produced little aerosol during the third trial. The different performance properties of the two units were attributed to the atomizers. There was significant variability between and within brands in the airflow rate required to produce aerosol, pressure drop, length of time cartridges lasted, and production of aerosol. Variation in performance properties within brands suggests a need for better quality control during e-cigarette manufacture.

  7. Contamination of disposable tonometer prisms during tonometry.

    PubMed

    Rajak, S N; Paul, J; Sharma, V; Vickers, S

    2006-03-01

    Due to the theoretical possibility of prion transmission in applanation tonometry, many ophthalmological units in the United Kingdom now use disposable tonometer prisms. We have investigated the potential for bacterial and viral transmission from the health practitioner to the patient via disposable prisms. All staff who perform applanation tonometry at the Sussex Eye Hospital (SEH) received a questionnaire to evaluate if the applanating face of the prism is touched during tonometry and the ease of use of the disposable prism compared to the reusable prisms that were previously used. We then cultured prisms handled by a random sample of staff members for common bacteria. Finally, we constructed a model to investigate the possibility of interpatient adenoviral transmission via disposable tonometer prisms. The questionnaire revealed that almost 50% of the staff admit to touching the applanating face of the tonometer prism prior to applanation. Cultures of the prisms grew a range of bacteria including Staphylococcus epidermidis, Staphylococcus aureus, and Bacillus species. The viral model suggested that adenovirus could be transmitted by applanation tonometry. The use of disposable prisms for applanation tonometry may reduce the risk of prion transmission but is not bacteriologically or virologically aseptic. This is a potential infection risk to patients.

  8. Effects of Visual Information on Wind-Evoked Escape Behavior of the Cricket, Gryllus bimaculatus.

    PubMed

    Kanou, Masamichi; Matsuyama, Akane; Takuwa, Hiroyuki

    2014-09-01

    We investigated the effects of visual information on wind-evoked escape behavior in the cricket, Gryllus bimaculatus. Most agitated crickets were found to retreat into a shelter made of cardboard installed in the test arena within a short time. As this behavior was thought to be a type of escape, we confirmed how a visual image of a shelter affected wind-evoked escape behavior. Irrespective of the brightness of the visual background (black or white) or the absence or presence of a shelter, escape jumps were oriented almost 180° opposite to the source of the air puff stimulus. Therefore, the direction of wind-evoked escape depends solely depended on the direction of the stimulus air puff. In contrast, the turning direction of the crickets during the escape was affected by the position of the visual image of the shelter. During the wind-evoked escape jump, most crickets turned in the direction in which a shelter was presented. This behavioral nature is presumably necessary for crickets to retreat into a shelter within a short time after their escape jump.

  9. Compositional profiling and sensorial analysis of multi-wholegrain extruded puffs as affected by fructan inclusion.

    PubMed

    Handa, C; Goomer, S

    2015-09-01

    Rice grits, corn grits, pulse, wholegrain - finger millet and sorghum were utilized in the production of multigrain extruded puffs using a single screw extruder. The effect of inclusion of fructan - fructoligosaccharide in multi-wholegrain (MWG) extruded puffs was examined. MWG fructan enriched puffs puffs had 450 % higher dietary fiber content than the control puff (CP). These puffs can be categorized as 'Good Source' of fiber as it suffices 17.2 % DV of fiber. Puffs were rated 8.1 ± 0.6, 8.3 ± 0.7, 8.1 ± 0.6, 7.5 ± 0.5 and 8.2 ± 0.6 for color, flavor, texture, appearance and overall acceptability respectively. The scores for all the attributes were found to be not significantly different (p < 0.05) from CP. The MWG fructan puffs were rated higher on flavor than the CP having a score of 8.3 ± 0.7 as opposed to 8.2 ± 0.4 for CP. This indicates that the nutritional quality and acceptability of MWG extruded puffs could be improved by the inclusion of fructans.

  10. Quantitative assessment of corneal vibrations during intraocular pressure measurement with the air-puff method in patients with keratoconus.

    PubMed

    Koprowski, Robert; Ambrósio, Renato

    2015-11-01

    One of the current methods for measuring intraocular pressure is the air-puff method. A tonometer which uses this method is the Corvis device. With the ultra-high-speed (UHS) Scheimpflug camera, it is also possible to observe corneal deformation during measurement. The use of modern image analysis and processing methods allows for analysis of higher harmonics of corneal deflection above 100 Hz. 493 eyes of healthy subjects and 279 eyes of patients with keratoconus were used in the measurements. For each eye, 140 corneal deformation images were recorded during intraocular pressure measurement. Each image was recorded every 230 µs and had a resolution of 200 × 576 pixels. A new, original algorithm for image analysis and processing has been proposed. It enables to separate the eyeball reaction as well as low-frequency and high-frequency corneal deformations from the eye response to an air puff. Furthermore, a method for classification of healthy subjects and patients with keratoconus based on decision trees has been proposed. The obtained results confirm the possibility to distinguish between patients with keratoconus and healthy subjects. The features used in this classification are directly related to corneal vibrations. They are only available in the proposed software and provide specificity of 98%, sensitivity-85%, and accuracy-92%. This confirms the usefulness of the proposed method in this type of classification that uses corneal vibrations during intraocular pressure measurement with the Corvis tonometer. With the new proposed algorithm for image analysis and processing allowing for the separation of individual features from a corneal deformation image, it is possible to: automatically measure corneal vibrations in a few characteristic points of the cornea, obtain fully repeatable measurement of vibrations for the same registered sequence of images and measure vibration parameters for large inter-individual variability in patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Synaptic Activity in Serotonergic Neurons Is Required for Air-Puff Stimulated Flight in Drosophila melanogaster

    PubMed Central

    Sadaf, Sufia; Birman, Serge; Hasan, Gaiti

    2012-01-01

    Background Flight is an integral component of many complex behavioral patterns in insects. The giant fiber circuit has been well studied in several insects including Drosophila. However, components of the insect flight circuit that respond to an air-puff stimulus and comprise the flight central pattern generator are poorly defined. Aminergic neurons have been implicated in locust, moth and Drosophila flight. Here we have investigated the requirement of neuronal activity in serotonergic neurons, during development and in adults, on air-puff induced flight in Drosophila. Methodology/Principal Findings To target serotonergic neurons specifically, a Drosophila strain that contains regulatory regions from the TRH (Tryptophan Hydroxylase) gene linked to the yeast transcription factor GAL4 was used. By blocking synaptic transmission from serotonergic neurons with a tetanus toxin transgene or by hyperpolarisation with Kir2.1, close to 50% adults became flightless. Temporal expression of a temperature sensitive Dynamin mutant transgene (Shits) suggests that synaptic function in serotonergic neurons is required both during development and in adults. Depletion of IP3R in serotonergic neurons via RNAi did not affect flight. Interestingly, at all stages a partial requirement for synaptic activity in serotonergic neurons was observed. The status of serotonergic neurons was investigated in the central nervous system of larvae and adults expressing tetanus toxin. A small but significant reduction was observed in serotonergic cell number in adult second thoracic segments from flightless tetanus toxin expressing animals. Conclusions These studies show that loss of synaptic activity in serotonergic neurons causes a flight deficit. The temporal focus of the flight deficit is during pupal development and in adults. The cause of the flight deficit is likely to be loss of neurons and reduced synaptic function. Based on the partial phenotypes, serotonergic neurons appear to be modulatory, rather than an intrinsic part of the flight circuit. PMID:23029511

  12. Plasma puff initiation of high Coulomb transfer switches

    NASA Technical Reports Server (NTRS)

    Venable, D. D.; Choi, E. H.

    1990-01-01

    The plasma-puff triggering mechanism based on a hypocycloidal pinch geometry was investigated to determine the optimal operating conditions for the azimuthally uniform surface flashover which initiates plasma-puff under wide range of fill gas pressure of Ar, He and N2. The optimal fill gas pressure for the azimuthally uniform plasma-puff was about 120 mTorr and 450 Torr for He and N2, and between 120 mTorr and 5 Torr for Ar. The inverse pinch switch was triggered with the plasma-puff and the switching capability under various electrical parameters and working gas pressures of Ar, He and N2 was determined. It was also shown that the azimuthally uniform switching discharges were dependent on the type of fill gas and its fill pressure. A new concept of plasma-focus driven plasma-puff was also discussed in comparison with the hypocycloidal pinch plasma-puff triggering. The main discharge of inverse pinch switch with plasma-focus driven plasma-puff trigger is found to be more azimuthally uniform than that with hypocycloidal pinch plasma-puff trigger in a gas pressure region between 80 mTorr and 1 Torr.

  13. Comparison of ICare and IOPen vs Goldmann applanation tonometry according to international standards 8612 in glaucoma patients.

    PubMed

    Pahlitzsch, Milena; Brünner, Jeanette; Gonnermann, Johannes; Maier, Anna-Karina B; Torun, Necip; Bertelmann, Eckart; Klamann, Matthias Kj

    2016-01-01

    To compare IOPen and ICare rebound tonometry to Goldmann applanation tonometry (GAT) according to International Standards Organization (ISO) 8612 criteria. Totally 191 eyes ( n =107 individuals) were included. Criteria of ISO 8612 were fulfilled: 3 clusters of IOP, measured by GAT, were formed. The GAT results were given as mean±standard deviation. GAT (19.7±0.5 mm Hg) showed a significant correlation to ICare (19.8±0.5 mm Hg) ( r =0.547, P <0.001) and IOPen (19.5±0.5 mm Hg) ( r =0.526, P <0.001). According to ISO 8612 criteria in all 3 IOP groups the number of outliers (of the 95% limits of agreement) exceeded 5% for ICare and IOPen vs GAT: No.1 ( n =68) 29.4% and 22.1%, No.2 ( n =62) 35.5% and 37.1%, No.3 ( n =61) 26.2% and 42.6%, respectively. The strict requirements of the ISO 8612 are not fulfilled in a glaucoma collective by ICare and IOPen at present. As long as the Goldmann tonometry is applicable it should be used first of all for reproducible IOP readings. ICare and IOPen tonometry should be considered as an alternative tool, if application of Goldmann tonometry is not possible.

  14. A comparison between a combination of ipratropium bromide plus fenoterol in a single metered dose inhaler (Duovent) and salbutamol in asthma.

    PubMed Central

    Flint, K. C.; Hockley, B.; Johnson, N. M.

    1983-01-01

    The efficacy of a single metered dose inhaler containing a combination of fenoterol (100 micrograms/puff) and ipratropium bromide (40 micrograms/puff) has been assessed in 12 asthmatics. We conclude that the bronchodilator effect of 2 puffs of the combination inhaler was significantly greater than that achieved by 2 puffs of salbutamol (100 micrograms/puff). PMID:6227877

  15. Measurement of intraocular pressure in healthy unanesthetized inland bearded dragons (Pogona vitticeps).

    PubMed

    Schuster, Eva J; Strueve, Julia; Fehr, Michael J; Mathes, Karina A

    2015-06-01

    To evaluate the use of rebound and applanation tonometry for the measurement of intraocular pressure (IOP) and to assess diurnal variations in and the effect of topical anesthesia on the IOP of healthy inland bearded dragons (Pogona vitticeps). 56 bearded dragons from 4 months to 11 years old. For each animal following an initial ophthalmic examination, 3 IOP measurements were obtained on each eye between 9 AM and 10 AM, 1 PM and 2 PM, and 5 PM and 7 PM by use of rebound and applanation tonometry. An additional measurement was obtained by rebound tonometry for each eye in the evening following the application of a topical anesthetic to evaluate changes in the tolerance of the animals to the tonometer. Descriptive data were generated, and the effects of sex, time of day, and topical anesthesia on IOP were evaluated. Bearded dragons did not tolerate applanation tonometry even following topical anesthesia. Median daily IOP as determined by rebound tonometry was 6.16 mm Hg (95% confidence interval, 5.61 to 6.44 mm Hg). The IOP did not differ significantly between the right and left eyes. The IOP was highest in the morning, which indicated that the IOP in this species undergoes diurnal variations. Topical anesthesia did not significantly affect IOP, but it did improve the compliance for all subjects. Results indicated that rebound tonometry, but not applanation tonometry, was appropriate for measurement of IOP in bearded dragons. These findings provided preliminary guidelines for IOP measurement and ophthalmic evaluation in bearded dragons.

  16. Fundamentals and Advances in Tonometry.

    PubMed

    Nuyen, Brenda; Mansouri, Kaweh

    2015-01-01

    According to the World Health Organization, glaucoma is the leading cause of irreversible blindness worldwide. Although intraocular pressure (IOP) is not considered any more to be a defining feature of the disease, its lowering remains the only treatment option for glaucoma. Therefore, accurate and precise measurement of IOP is the cornerstone of glaucoma. Intraocular pressure is a highly dynamic physiological parameter with individual circadian rhythms. The main limitation of current tonometry methods remains the static and mostly office-based nature of their measurements. This review provides a brief historical overview on tonometry and discusses current tonometry instruments. In recent years, approaches to 24-hour IOP monitoring have been introduced, and there is hope that they may become part of routine clinical management in the future.

  17. INPUFF: A SINGLE SOURCE GAUSSIAN PUFF DISPERSION ALGORITHM. USER'S GUIDE

    EPA Science Inventory

    INPUFF is a Gaussian INtegrated PUFF model. The Gaussian puff diffusion equation is used to compute the contribution to the concentration at each receptor from each puff every time step. Computations in INPUFF can be made for a single point source at up to 25 receptor locations. ...

  18. Accuracy of peripheral arterial tonometry in the diagnosis of obstructive sleep apnea.

    PubMed

    Pinto, José Antonio; Godoy, Luciana Balester Mello de; Ribeiro, Renata Coutinho; Mizoguchi, Elcio Izumi; Hirsch, Lina Ana Medeiros; Gomes, Leonardo Marques

    2015-01-01

    The use of handheld devices that assess peripheral arterial tonometry has emerged as an auxiliary method for assessment and diagnosis of obstructive sleep apnea syndrome. To evaluate the accuracy of peripheral arterial tonometry in the diagnosis of obstructive sleep apnea. Contemporary cohort cross-sectional study. Thirty patients with suspected obstructive sleep apnea underwent peripheral arterial tonometry and assisted nocturnal polysomnography concomitantly. The mean apnea/hypopnea index by peripheral arterial tonometry was significantly higher than that by polysomnography (p<0.001), but the values of both sleep studies were significantly correlated (r=0.762). There was a high correlation between variables: minimum oxygen saturation (r=0.842, p<0.001), oxygen saturation<90% (r=0.799, p<0.001), and mean heart rate (r=0.951, p<0.001). Sensitivity and specificity were 60% and 96.2% (AUC: 0.727; p=0.113), respectively, when at a threshold value of 5 events/h. In severe cases (≥30 events/h), the result was a sensitivity of 77.8% and a specificity of 86.4% (AUC: 0.846, p=0.003). Peripheral arterial tonometry is a useful portable device for the diagnosis of obstructive sleep apnea; its accuracy is higher in moderate and severe cases. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  19. Electronic Cigarette Topography in the Natural Environment

    PubMed Central

    Morabito, P. N.; Roundtree, K. A.

    2015-01-01

    This paper presents the results of a clinical, observational, descriptive study to quantify the use patterns of electronic cigarette users in their natural environment. Previously published work regarding puff topography has been widely indirect in nature, and qualitative rather than quantitative, with the exception of three studies conducted in a laboratory environment for limited amounts of time. The current study quantifies the variation in puffing behaviors among users as well as the variation for a given user throughout the course of a day. Puff topography characteristics computed for each puffing session by each subject include the number of subject puffs per puffing session, the mean puff duration per session, the mean puff flow rate per session, the mean puff volume per session, and the cumulative puff volume per session. The same puff topography characteristics are computed across all puffing sessions by each single subject and across all subjects in the study cohort. Results indicate significant inter-subject variability with regard to puffing topography, suggesting that a range of representative puffing topography patterns should be used to drive machine-puffed electronic cigarette aerosol evaluation systems. PMID:26053075

  20. Electronic Cigarette Topography in the Natural Environment.

    PubMed

    Robinson, R J; Hensel, E C; Morabito, P N; Roundtree, K A

    2015-01-01

    This paper presents the results of a clinical, observational, descriptive study to quantify the use patterns of electronic cigarette users in their natural environment. Previously published work regarding puff topography has been widely indirect in nature, and qualitative rather than quantitative, with the exception of three studies conducted in a laboratory environment for limited amounts of time. The current study quantifies the variation in puffing behaviors among users as well as the variation for a given user throughout the course of a day. Puff topography characteristics computed for each puffing session by each subject include the number of subject puffs per puffing session, the mean puff duration per session, the mean puff flow rate per session, the mean puff volume per session, and the cumulative puff volume per session. The same puff topography characteristics are computed across all puffing sessions by each single subject and across all subjects in the study cohort. Results indicate significant inter-subject variability with regard to puffing topography, suggesting that a range of representative puffing topography patterns should be used to drive machine-puffed electronic cigarette aerosol evaluation systems.

  1. Developmental ecdysteroid titers and DNA puffs in larvae of two sciarid species, Rhynchosciara americana and Rhynchosciara milleri (Diptera: Sciaridae).

    PubMed

    Soares, M A M; Hartfelder, K; Tesserolli de Souza, J M; Stocker, A J

    2015-10-01

    Ecdysteroid titers, developmental landmarks and the presence of prominent amplifying regions (DNA puffs) have been compared during late larval to pupal development in four groups of Rhynchosciara americana larvae and in R. americana and Rhynchosciara milleri. Three prominent DNA puffs (B2, C3 and C8) expand and regress sequentially on the rising phase of the 20-hydroxyecdysone (20E) titer in R. americana as a firm, cellular cocoon is being constructed. A sharp rise in 20E coincides with the regression of these puffs. The shape of the 20E curve is similar in R. milleri, a species that does not construct a massive cocoon, but the behavior of certain DNA puffs and their temporal relationship to the curve differs. Regions corresponding to B2 and C3 can be identified in R. milleri by banding pattern similarity with R. americana chromosomes and, in the case of B2, by hybridization to an R. americana probe. A B2 puff appears in R. milleri as the 20E titer rises but remains small in all gland regions. A puff similar to the R. americana C3 puff occurs in posterior gland cells of R. milleri (C3(Rm)) after the B2 puff, but this site did not hybridize to R. americana C3 probes. C3(Rm) incorporated (3)H-thymidine above background, but showed less post-puff DNA accumulation than C3 of R. americana. R. americana C8 probes hybridized to a more distal region of the R. milleri C chromosome that did not appear to amplify or form a large puff. These differences can be related to developmental differences, in particular differences in cocoon construction between the two species.

  2. Eye-Blink Conditioning Is Associated with Changes in Synaptic Ultrastructure in the Rabbit Interpositus Nuclei

    ERIC Educational Resources Information Center

    Weeks, Andrew C. W.; Connor, Steve; Hinchcliff, Richard; LeBoutillier, Janelle C.; Thompson, Richard F.; Petit, Ted L.

    2007-01-01

    Eye-blink conditioning involves the pairing of a conditioned stimulus (usually a tone) to an unconditioned stimulus (air puff), and it is well established that an intact cerebellum and interpositus nucleus, in particular, are required for this form of classical conditioning. Changes in synaptic number or structure have long been proposed as a…

  3. Effects of income on drug choice in humans.

    PubMed Central

    DeGrandpre, R J; Bickel, W K; Rizvi, S A; Hughes, J R

    1993-01-01

    The effects of income (money available to spend during the experimental session) on human choice were examined in a concurrent-schedule arrangement. Subjects were 7 nicotine-dependent smokers, and reinforcers were puffs on the subject's usual brand of cigarette ("own") and puffs on a less preferred brand of cigarette with equal nicotine content ("other"). Across sessions, income varied and the price of the two reinforcers was held constant, with the other puffs one fifth the price of the own puffs. As income increased, consumption of own puffs increased while consumption of the less expensive other puffs decreased. These effects of income on choice were highly consistent across subjects. For some subjects, however, income had little effect on total puff consumption. Finally, an additional condition examined whether price and income manipulations would have functionally equivalent effects on choice by repeating an income condition in which the price of the other brand was increased. Although the increased price of the other puffs decreased their consumption in 4 subjects, 2 subjects showed increased consumption of the other puffs at the higher price. The results, when defined in economic terms, indicate that the own puffs were a normal good (consumption and income are directly related), the other puffs were an inferior good (consumption and income are inversely related), and the direct relationship between consumption of the other puffs and their price is defined as a Giffengood effect. The latter result also suggests that for these 2 subjects, price and income manipulations had equivalent effects on choice. These results extend findings from previous studies that have examined the effects of income on choice responding to human subjects and drug reinforcers, and provide a framework for further experimental tests of the effects of income on human choice behavior. Methodological and theoretical implications for the study of choice and for behavioral pharmacology are discussed. PMID:8315366

  4. Effects of user puff topography, device voltage, and liquid nicotine concentration on electronic cigarette nicotine yield: measurements and model predictions.

    PubMed

    Talih, Soha; Balhas, Zainab; Eissenberg, Thomas; Salman, Rola; Karaoghlanian, Nareg; El Hellani, Ahmad; Baalbaki, Rima; Saliba, Najat; Shihadeh, Alan

    2015-02-01

    Some electronic cigarette (ECIG) users attain tobacco cigarette-like plasma nicotine concentrations while others do not. Understanding the factors that influence ECIG aerosol nicotine delivery is relevant to regulation, including product labeling and abuse liability. These factors may include user puff topography, ECIG liquid composition, and ECIG design features. This study addresses how these factors can influence ECIG nicotine yield. Aerosols were machine generated with 1 type of ECIG cartridge (V4L CoolCart) using 5 distinct puff profiles representing a tobacco cigarette smoker (2-s puff duration, 33-ml/s puff velocity), a slow average ECIG user (4 s, 17 ml/s), a fast average user (4 s, 33 ml/s), a slow extreme user (8 s, 17 ml/s), and a fast extreme user (8 s, 33 ml/s). Output voltage (3.3-5.2 V or 3.0-7.5 W) and e-liquid nicotine concentration (18-36 mg/ml labeled concentration) were varied. A theoretical model was also developed to simulate the ECIG aerosol production process and to provide insight into the empirical observations. Nicotine yields from 15 puffs varied by more than 50-fold across conditions. Experienced ECIG user profiles (longer puffs) resulted in higher nicotine yields relative to the tobacco smoker (shorter puffs). Puff velocity had no effect on nicotine yield. Higher nicotine concentration and higher voltages resulted in higher nicotine yields. These results were predicted well by the theoretical model (R (2) = 0.99). Depending on puff conditions and product features, 15 puffs from an ECIG can provide far less or far more nicotine than a single tobacco cigarette. ECIG emissions can be predicted using physical principles, with knowledge of puff topography and a few ECIG device design parameters. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Effects of User Puff Topography, Device Voltage, and Liquid Nicotine Concentration on Electronic Cigarette Nicotine Yield: Measurements and Model Predictions

    PubMed Central

    Talih, Soha; Balhas, Zainab; Eissenberg, Thomas; Salman, Rola; Karaoghlanian, Nareg; El Hellani, Ahmad; Baalbaki, Rima; Saliba, Najat

    2015-01-01

    Introduction: Some electronic cigarette (ECIG) users attain tobacco cigarette–like plasma nicotine concentrations while others do not. Understanding the factors that influence ECIG aerosol nicotine delivery is relevant to regulation, including product labeling and abuse liability. These factors may include user puff topography, ECIG liquid composition, and ECIG design features. This study addresses how these factors can influence ECIG nicotine yield. Methods: Aerosols were machine generated with 1 type of ECIG cartridge (V4L CoolCart) using 5 distinct puff profiles representing a tobacco cigarette smoker (2-s puff duration, 33-ml/s puff velocity), a slow average ECIG user (4 s, 17 ml/s), a fast average user (4 s, 33 ml/s), a slow extreme user (8 s, 17 ml/s), and a fast extreme user (8 s, 33 ml/s). Output voltage (3.3–5.2 V or 3.0–7.5 W) and e-liquid nicotine concentration (18–36 mg/ml labeled concentration) were varied. A theoretical model was also developed to simulate the ECIG aerosol production process and to provide insight into the empirical observations. Results: Nicotine yields from 15 puffs varied by more than 50-fold across conditions. Experienced ECIG user profiles (longer puffs) resulted in higher nicotine yields relative to the tobacco smoker (shorter puffs). Puff velocity had no effect on nicotine yield. Higher nicotine concentration and higher voltages resulted in higher nicotine yields. These results were predicted well by the theoretical model (R 2 = 0.99). Conclusions: Depending on puff conditions and product features, 15 puffs from an ECIG can provide far less or far more nicotine than a single tobacco cigarette. ECIG emissions can be predicted using physical principles, with knowledge of puff topography and a few ECIG device design parameters. PMID:25187061

  6. Corneal Vibrations during Intraocular Pressure Measurement with an Air-Puff Method

    PubMed Central

    Wilczyński, Sławomir

    2018-01-01

    Introduction The paper presents a commentary on the method of analysis of corneal vibrations occurring during eye pressure measurements with air-puff tonometers, for example, Corvis. The presented definition and measurement method allow for the analysis of image sequences of eye responses—cornea deformation. In particular, the outer corneal contour and sclera fragments are analysed, and 3D reconstruction is performed. Methods On this basis, well-known parameters such as eyeball reaction or corneal response are determined. The next steps of analysis allow for automatic and reproducible separation of four different corneal vibrations. These vibrations are associated with (1) the location of the maximum of cornea deformation; (2) the cutoff area measured in relation to the cornea in a steady state; (3) the maximum of peaks occurring between applanations; and (4) the other characteristic points of the corneal contour. Results The results obtained enable (1) automatic determination of the amplitude of vibrations; (2) determination of the frequency of vibrations; and (3) determination of the correlation between the selected types of vibrations. Conclusions These are diagnostic features that can be directly applied clinically for new and archived data. PMID:29610655

  7. An Experiment Investigation of Fully-Modulated, Turbulent Diffusion Flames in Reduced Gravity

    NASA Technical Reports Server (NTRS)

    Hermanson, J. C.; Johari, H.; Usowicz, J. E.; Stocker, D. P.; Nagashima, T.; Obata, S.

    1999-01-01

    Pulsed combustion appears to have the potential to provide for rapid fuel/air mixing, compact and economical combustors, and reduced exhaust emissions. The ultimate objective of this program is to increase the fundamental understanding of the fuel/air mixing and combustion behavior of pulsed, turbulent diffusion flames by conducting experiments in microgravity. In this research the fuel jet is fully-modulated (i.e., completely shut off between pulses) by an externally controlled valve system. This can give rise to drastic modification of the combustion and flow characteristics of flames, leading to enhanced fuel/air mixing mechanisms not operative for the case of acoustically excited or partially-modulated jets. In addition, the fully-modulated injection approach avoids the strong acoustic forcing present in pulsed combustion devices, significantly simplifying the mixing and combustion processes. Relatively little is known of the behavior of turbulent flames in reduced-gravity conditions, even in the absence of pulsing. The goal of this Flight-Definition experiment (PUFF, for PUlsed-Fully Flames) is to establish the behavior of fully-modulated, turbulent diffusion flames under microgravity conditions. Fundamental issues to be addressed in this experiment include the mechanisms responsible for the flame length decrease for fully-modulated, turbulent diffusion flames compared with steady flames, the impact of buoyancy on the mixing and combustion characteristics of these flames, and the characteristics of turbulent flame puffs under fully momentum-dominated conditions.

  8. Goldmann tonometry after hyperopic laser in situ keratomileusis: comparison between retreated and nonretreated patients.

    PubMed

    Sanchis-Gimeno, Juan A; Lleó-Pérez, Antonio; Rahhal, Saleh M; Alonso, Luis

    2004-10-01

    To identify differences in applanation tonometry between retreated and nonretreated eyes (primary LASIK eyes) 6 months after hyperopic laser in situ keratomileusis. In a prospective study 100 eyes (100 patients) underwent conventional hyperopic laser in situ keratomileusis under a 160-microm flap. Central Goldmann applanation tonometry was determined before and 6 months after surgery in 78 (78%) primary LASIK eyes and before surgery and 6 months after the retreatment date in 22 (22%) retreated eyes. Preoperative mean tonometry was 14.96 +/- 1.96 mm Hg and 15.30 +/- 1.95 mm Hg in primary LASIK and retreated eyes, respectively. Six months after surgery it was 12.99 +/- 2.03 mm Hg (P < 0.001) and 12.67 +/- 2.20 mm Hg (P < 0.001), respectively. No significant differences in mean tonometry were found between retreated and primary LASIK eyes 6 months after surgery (P = 0.537). Decreased tonometric values were found in 20 retreated eyes (90.91%) and in 62 primary LASIK eyes (79.48%). Increased tonometric values higher than 1 mm Hg were found in 3 primary LASIK eyes (3.84%), but no retreated eyes showed increased values 6 months after surgery. Two retreated eyes (9.09%) and 10 primary LASIK eyes (79.49%) presented the same tonometric values before surgery and at the end of the study. After hyperopic laser in situ keratomileusis there was no significant difference in Goldmann applanation tonometry between retreated and primary LASIK eyes.

  9. Mining data on usage of electronic nicotine delivery systems (ENDS) from YouTube videos.

    PubMed

    Hua, My; Yip, Henry; Talbot, Prue

    2013-03-01

    The objective was to analyse and compare puff and exhalation duration for individuals using electronic nicotine delivery systems (ENDS) and conventional cigarettes in YouTube videos. Video data from YouTube videos were analysed to quantify puff duration and exhalation duration during use of conventional tobacco-containing cigarettes and ENDS. For ENDS, comparisons were also made between 'advertisers' and 'non-advertisers', genders, brands of ENDS, and models of ENDS within one brand. Puff duration (mean =2.4 s) for conventional smokers in YouTube videos (N=9) agreed well with prior publications. Puff duration was significantly longer for ENDS users (mean =4.3 s) (N = 64) than for conventional cigarette users, and puff duration varied significantly among ENDS brands. For ENDS users, puff duration and exhalation duration were not significantly affected by 'advertiser' status, gender or variation in models within a brand. Men outnumbered women by about 5:1, and most users were between 19 and 35 years of age. YouTube videos provide a valuable resource for studying ENDS usage. Longer puff duration may help ENDS users compensate for the apparently poor delivery of nicotine from ENDS. As with conventional cigarette smoking, ENDS users showed a large variation in puff duration (range =1.9-8.3 s). ENDS puff duration should be considered when designing laboratory and clinical trials and in developing a standard protocol for evaluating ENDS performance.

  10. Temperature Evolution of a 1 MA Triple-Nozzle Gas-Puff Z-Pinch

    NASA Astrophysics Data System (ADS)

    de Grouchy, Philip; Banasek, Jacob; Engelbrecht, Joey; Qi, Niansheng; Atoyan, Levon; Byvank, Tom; Cahill, Adam; Moore, Hannah; Potter, William; Ransohoff, Lauren; Hammer, David; Kusse, Bruce; Laboratory of Plasma Studies Team

    2015-11-01

    Mitigation of the Rayleigh-Taylor instability (RTI) plays a critical role in optimizing x-ray output at high-energy ~ 13 keV using the triple-nozzle Krypton gas-puff at Sandia National Laboratory. RTI mitigation by gas-puff density profiling using a triple-nozzle gas-puff valve has recently been recently demonstrated on the COBRA 1MA z-pinch at Cornell University. In support of this work we investigate the role of shell cooling in the growth of RTI during gas-puff implosions. Temperature measurements within the imploding plasma shell are recorded using a 527 nm, 10 GW Thomson scattering diagnostic for Neon, Argon and Krypton puffs. The mass-density profile is held constant at 22 microgram per centimeter for all three puffs and the temperature evolution of the imploding material is recorded. In the case of Argon puffs we find that the shell ion and electron effective temperatures remain in equilibrium at around 1keV for the majority of the implosion phase. In contrast scattered spectra from Krypton are dominated by of order 10 keV effective ion temperatures. Supported by the NNSA Stewardship Sciences Academic Programs.

  11. Characteristics of plasma-puff trigger for a inverse-pinch plasma switch

    NASA Technical Reports Server (NTRS)

    Choi, Eun H.; Venable, Demetrius D.; Han, Kwang S.; Lee, Ja H.

    1993-01-01

    The plasma-puff triggering mechanism based on a hypocycloidal pinch geometry was investigated to determine the optimal operating conditions for the azimuthally uniform surface flashover which initiates plasma-puff under wide ranges of fill gas pressure of Ar, He and N2. The optimal fill-gas pressure range for the azimuthally uniform plasma-puff was about 120 mTorr less than or equal to P(sub op) less than or equal to 450 Torr for He and N2. For Argon 120 mTorr is less than or equal to P(sub op) is less than or equal to 5 Torr. The inverse-pinch switch was triggered with the plasma-puff and the switching capability under various electrical parameters and working gas pressures of Ar, He and N2 was determined. The azimuthally uniform switching discharges were dependent on the type of fill gas and its fill pressure. A new concept of plasma-focus driven plasma-puff will be discussed in comparison with the current hypocycloidal-pinch plasma-puff triggering.

  12. Predicting and validating the motion of an ash cloud during the 2006 eruption of Mount Augustine volcano

    USGS Publications Warehouse

    Collins, Richard L.; Fochesatto, Javier; Sassen, Kenneth; Webley, Peter W.; Atkinson, David E.; Dean, Kenneson G.; Cahill, Catherine F.; Mizutani, Kohei

    2007-01-01

    On 11 January 2006, Mount Augustine volcano in southern Alaska began erupting after 20- year repose. The Anchorage Forecast Office of the National Weather Service (NWS) issued an advisory on 28 January for Kodiak City. On 31 January, Alaska Airlines cancelled all flights to and from Anchorage after multiple advisories from the NWS for Anchorage and the surrounding region. The Alaska Volcano Observatory (AVO) had reported the onset of the continuous eruption. AVO monitors the approximately 100 active volcanoes in the Northern Pacific. Ash clouds from these volcanoes can cause serious damage to an aircraft and pose a serious threat to the local communities, and to transcontinental air traffic throughout the Arctic and sub-Arctic region. Within AVO, a dispersion model has been developed to track the dispersion of volcanic ash clouds. The model, Puff, was used operational by AVO during the Augustine eruptive period. Here, we examine the dispersion of a volcanic ash (or aerosol) cloud from Mount Augustine across Alaska from 29 January through the 2 February 2006. We present the synoptic meteorology, the Puff predictions, and measurements from aerosol samplers, laser radar (or lidar) systems, and satellites. Aerosol samplers revealed the presence of volcanic aerosols at the surface at sites where Puff predicted the ash clouds movement. Remote sensing satellite data showed the development of the ash cloud in close proximity to the volcano consistent with the Puff predictions. Two lidars showed the presence of volcanic aerosol with consistent characteristics aloft over Alaska and were capable of detecting the aerosol, even in the presence of scattered clouds and where the ash cloud is too thin/disperse to be detected by remote sensing satellite data. The lidar measurements revealed the different trajectories of ash consistent with the Puff predictions. Dispersion models provide a forecast of volcanic ash cloud movement that might be undetectable by any other means but are still a significant hazard. Validation is the key to assessing the accuracy of any predictions. The study highlights the use of multiple and complementary observations used in detecting the trajectory ash cloud, both at the surface and aloft in the atmosphere.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webley, Peter W.; Atkinson, D.; Collins, Richard L.

    On 11 January 2006, Mount Augustine volcano in southern Alaska began erupting after 20-year repose. The Anchorage Forecast Office of the National Weather Service (NWS) issued an advisory on 28 January for Kodiak City. On 31 January, Alaska Airlines cancelled all flights to and from Anchorage after multiple advisories from the NWS for Anchorage and the surrounding region. The Alaska Volcano Observatory (AVO) had reported the onset of the continuous eruption. AVO monitors the approximately 100 active volcanoes in the Northern Pacific. Ash clouds from these volcanoes can cause serious damage to an aircraft and pose a serious threat tomore » the local communities, and to transcontinental air traffic throughout the Arctic and sub-Arctic region. Within AVO, a dispersion model has been developed to track the dispersion of volcanic ash clouds. The model, Puff, was used operational by AVO during the Augustine eruptive period. Here, we examine the dispersion of a volcanic ash cloud from Mount Augustine across Alaska from 29 January through the 2 February 2006. We present the synoptic meteorology, the Puff predictions, and measurements from aerosol samplers, laser radar (or lidar) systems, and satellites. UAF aerosol samplers revealed the presence of volcanic aerosols at the surface at sites where Puff predicted the ash clouds movement. Remote sensing satellite data showed the development of the ash cloud in close proximity to the volcano and a sulfur-dioxide cloud further from the volcano consistent with the Puff predictions. Lidars showed the presence of volcanic aerosol with consistent characteristics aloft over Alaska and were capable of detecting the aerosol, even in the presence of scattered clouds and where the cloud is too thin/disperse to be detected by remote sensing satellite data. The lidar measurements revealed the different trajectories of ash consistent with the Puff predictions. Dispersion models provide a forecast of volcanic ash cloud movement that might be undetectable by any other means but are still a significant hazard. Validation is the key to assessing the accuracy of any future predictions. The study highlights the use of multiple and complementary observations used in detecting the trajectory ash cloud, both at the surface and aloft within the atmosphere.« less

  14. An experimental test of the effect of acute anxious arousal and anxiety sensitivity on negative reinforcement smoking.

    PubMed

    Farris, Samantha G; Zvolensky, Michael J

    2016-07-01

    Although anxiety sensitivity has been reliably associated with smoking-anxiety comorbidity, there has not been a test of whether this construct moderates the effect of acute anxious arousal on actual smoking behavior. The present study utilized an experimental design to test the moderating role of anxiety sensitivity on laboratory-induced anxious arousal in terms of smoking urges and topography (puff style). Participants were adult daily smokers (n=90; Mage=43.6 SD =9.7); average 15.8 cigarettes per day). A between-subjects design was used; participants were randomly assigned to complete a biological challenge procedure consisting of either a single vital capacity inhalation of 35% carbon dioxide (CO2)-enriched air mixture or compressed room air. Smoking urges and smoking topography (puff behavior) were assessed before and after the challenge. Results revealed a significant interaction between anxiety sensitivity and experimental condition (b=-9.96, p=0.014), such that high anxiety sensitive smokers exposed to 35% CO2-enriched air reported significantly lower levels of smoking urges, relative to low anxiety sensitive smokers; the conditional effect of anxiety sensitivity was not observed for the room air condition. There were no significant interaction effects of experimental manipulation by anxiety sensitivity for any of the smoking topography outcomes. The present results suggest for smokers with higher levels of anxiety sensitivity, the acute experience of anxious arousal is related to decreased subjective smoking urges. These data invite future research to explore the reasons for dampened smoking urges, including cardiorespiratory symptom severity. © The Author(s) 2016.

  15. Digital Photoplethysmography for Assessment of Arterial Stiffness: Repeatability and Comparison with Applanation Tonometry

    PubMed Central

    Östling, Gerd; Nilsson, Peter M.

    2015-01-01

    Introduction Arterial stiffness is an independent risk factor for cardiovascular morbidity and can be assessed by applanation tonometry by measuring pulse wave velocity (PWV) and augmentation index (AIX) by pressure pulse wave analysis (PWA). As an inexpensive and operator independent alternative, photoelectric plethysmography (PPG) has been introduced with analysis of the digital volume pulse wave (DPA) and its second derivatives of wave reflections. Objective The objective was to investigate the repeatability of arterial stiffness parameters measured by digital pulse wave analysis (DPA) and the associations to applanation tonometry parameters. Methods and Results 112 pregnant and non-pregnant individuals of different ages and genders were examined with SphygmoCor arterial wall tonometry and Meridian DPA finger photoplethysmography. Coefficients of repeatability, Bland-Altman plots, intraclass correlation coefficients and correlations to heart rate (HR) and body height were calculated for DPA variables, and the DPA variables were compared to tonometry variables left ventricular ejection time (LVET), PWV and AIX. No DPA variable showed any systematic measurement error or excellent repeatability, but dicrotic index (DI), dicrotic dilatation index (DDI), cardiac ejection elasticity index (EEI), aging index (AI) and second derivatives of the crude pulse wave curve, b/a and e/a, showed good repeatability. Overall, the correlations to AIX were better than to PWV, with correlations coefficients >0.70 for EEI, AI and b/a. Considering the level of repeatability and the correlations to tonometry, the overall best DPA parameters were EEI, AI and b/a. The two pansystolic time parameters, ejection time compensated (ETc) by DPA and LVET by tonometry, showed a significant but weak correlation. Conclusion For estimation of the LV function, ETc, EEI and b/a are suitable, for large artery stiffness EEI, and for small arteries DI and DDI. The only global parameter, AI, showed a high repeatability and the overall best correlations with AIX and PWV. PMID:26291079

  16. Statespace geometry of puff formation in pipe flow

    NASA Astrophysics Data System (ADS)

    Budanur, Nazmi Burak; Hof, Bjoern

    2017-11-01

    Localized patches of chaotically moving fluid known as puffs play a central role in the transition to turbulence in pipe flow. Puffs coexist with the laminar flow and their large-scale dynamics sets the critical Reynolds number: When the rate of puff splitting exceeds that of decaying, turbulence in a long pipe becomes sustained in a statistical sense. Since puffs appear despite the linear stability of the Hagen-Poiseuille flow, one expects them to emerge from the bifurcations of finite-amplitude solutions of Navier-Stokes equations. In numerical simulations of pipe flow, Avila et al., discovered a pair of streamwise localized relative periodic orbits, which are time-periodic solutions with spatial drifts. We combine symmetry reduction and Poincaré section methods to compute the unstable manifolds of these orbits, revealing statespace structures associated with different stages of puff formation.

  17. Behavioral economic substitutability of e-cigarettes, tobacco cigarettes, and nicotine gum.

    PubMed

    Johnson, Matthew W; Johnson, Patrick S; Rass, Olga; Pacek, Lauren R

    2017-07-01

    The public health impact of e-cigarettes may depend on their substitutability for tobacco cigarettes. Dual users of e-cigarettes and tobacco cigarettes completed purchasing tasks in which they specified daily use levels under hypothetical conditions that varied the availability and price of e-cigarettes, tobacco cigarettes, and nicotine gum (for those with nicotine gum experience). When either e-cigarettes or tobacco cigarettes were the only available commodity, as price per puff increased, purchasing decreased, revealing similar reinforcement profiles. When available concurrently, as the price of tobacco puffs increased, purchasing of tobacco puffs decreased while purchasing of fixed-price e-cigarette puffs increased. Among those with nicotine gum experience, when the price of tobacco puffs was closest to the actual market value of tobacco puffs, e-cigarette availability decreased median tobacco puff purchases by 44% compared to when tobacco was available alone. In contrast, nicotine gum availability caused no decrease in tobacco puff purchases. E-cigarettes may serve as a behavioral economic substitute for tobacco cigarettes, and may be a superior substitute compared to nicotine gum in their ability to decrease tobacco use. Although important questions remain regarding the health impacts of e-cigarettes, these data are consistent with the possibility that e-cigarettes may serve as smoking cessation/reduction aids.

  18. Measurement of nitrogen dioxide in cigarette smoke using quantum cascade tunable infrared laser differential absorption spectroscopy (TILDAS)

    NASA Astrophysics Data System (ADS)

    Shorter, Joanne H.; Nelson, David D.; Zahniser, Mark S.; Parrish, Milton E.; Crawford, Danielle R.; Gee, Diane L.

    2006-04-01

    Although nitrogen dioxide (NO 2) has been previously reported to be present in cigarette smoke, the concentration estimates were derived from kinetic calculations or from measurements of aged smoke, where NO 2 was formed some time after the puff was taken. The objective of this work was to use tunable infrared laser differential absorption spectroscopy (TILDAS) equipped with a quantum cascade (QC) laser to determine if NO 2 could be detected and quantified in a fresh puff of cigarette smoke. A temporal resolution of ˜0.16 s allowed measurements to be taken directly as the NO 2 was formed during the puff. Sidestream cigarette smoke was sampled to determine if NO 2 could be detected using TILDAS. Experiments were conducted using 2R4F Kentucky Reference cigarettes with and without a Cambridge filter pad. NO 2 was detected only in the lighting puff of whole mainstream smoke (without a Cambridge filter pad), with no NO 2 detected in the subsequent puffs. The measurement precision was ˜1.0 ppbV Hz -1/2, which allows a detection limit of ˜0.2 ng in a 35 ml puff volume. More NO 2 was generated in the lighting puff using a match or blue flame lighter (29 ± 21 ng) than when using an electric lighter (9 ± 3 ng). In the presence of a Cambridge filter pad, NO 2 was observed in the gas phase mainstream smoke for every puff (total of 200 ± 30 ng/cigarette) and is most likely due to smoke chemistry taking place on the Cambridge filter pad during the smoke collection process. Nitrogen dioxide was observed continuously in the sidestream smoke starting with the lighting puff.

  19. Nespoli performs periodic maintenance on the PuFF Experiment

    NASA Image and Video Library

    2011-02-14

    ISS026-E-027009 (14 Feb. 2011) --- European Space Agency (ESA) astronaut Paolo Nespoli, Expedition 26 flight engineer, performs periodic maintenance on the Pulmonary Function in Flight (PuFF) experiment by re-greasing the PuFF calibration syringe in the Columbus laboratory of the International Space Station.

  20. Group Waterpipe Tobacco Smoking Increases Smoke Toxicant Concentration

    PubMed Central

    Ramôa, Carolina P.; Shihadeh, Alan; Salman, Rola

    2016-01-01

    Abstract Introduction: Waterpipe tobacco smoking is a global health concern. Laboratory research has focused on individual waterpipe users while group use is common. This study examined user toxicant exposure and smoke toxicant yield associated with individual and group waterpipe smoking. Methods: Twenty-two pairs of waterpipe smokers used a waterpipe individually and as a dyad. Before and after smoking, blood was sampled and expired carbon monoxide (CO) measured; puff topography was recorded throughout. One participant from each pair was selected randomly and their plasma nicotine and expired air CO concentrations were compared when smoking alone to when smoking as part of a dyad. Recorded puff topography was used to machine-produce smoke that was analyzed for toxicant content. Results: There was no difference in mean plasma nicotine concentration when an individual smoked as part of a dyad (mean = 14.9ng/ml; standard error of the mean [ SEM ] = 3.0) compared to when smoking alone (mean = 10.0ng/ml; SEM = 1.5). An individual smoking as part of as a dyad had, on average, lower CO (mean = 15.8 ppm; SEM = 2.0) compared to when smoking alone (mean= 21.3 ppm; SEM = 2.7). When two participants smoked as a dyad they took, on average, more puffs (mean = 109.8; SEM = 7.6) than a singleton smoker (mean = 77.7; SEM = 8.1) and a shorter interpuff interval (IPI; dyad mean = 23.8 seconds; SEM = 1.9; singleton mean = 40.8 seconds; SEM = 4.8). Higher concentrations of several toxicants were observed in dyad-produced smoke. Discussion: Dyad smoking may increase smoke toxicant content, likely due to the dyad’s shorter IPIs and greater puff number. More work is needed to understand if group waterpipe smoking alters the health risks of waterpipe tobacco smoking. Implications: This study is the first to measure toxicants in smoke generated from a waterpipe when used by a dyad. Relative to smoke generated by a singleton, dyad smoke had higher concentration of some toxicants. These differences may be attributed to differences in puffing behavior, specifically the shorter IPI and greater puff number observed in the dyad condition. Relative to singleton smokers, dyad smokers were exposed to less CO, but nicotine exposure did not differ. More work is needed to assess the health effects of inhalation of more toxicant-laden smoke during group waterpipe use. PMID:26659913

  1. Optimization of Fat-Reduced Puff Pastry Using Response Surface Methodology.

    PubMed

    Silow, Christoph; Zannini, Emanuele; Axel, Claudia; Belz, Markus C E; Arendt, Elke K

    2017-02-22

    Puff pastry is a high-fat bakery product with fat playing a key role, both during the production process and in the final pastry. In this study, response surface methodology (RSM) was successfully used to evaluate puff pastry quality for the development of a fat-reduced version. The technological parameters modified included the level of roll-in fat, the number of fat layers (50-200) and the final thickness (1.0-3.5 mm) of the laminated dough. Quality characteristics of puff pastry were measured using the Texture Analyzer with an attached Extended Craft Knife (ECK) and Multiple Puncture Probe (MPP), the VolScan and the C-Cell imaging system. The number of fat layers and final dough thickness, in combination with the amount of roll-in fat, had a significant impact on the internal and external structural quality parameters. With technological changes alone, a fat-reduced (≥30%) puff pastry was developed. The qualities of fat-reduced puff pastries were comparable to conventional full-fat (33 wt %) products. A sensory acceptance test revealed no significant differences in taste of fatness or 'liking of mouthfeel'. Additionally, the fat-reduced puff pastry resulted in a significant ( p < 0.05) positive correlation to 'liking of flavor' and overall acceptance by the assessors.

  2. Optimization of Fat-Reduced Puff Pastry Using Response Surface Methodology

    PubMed Central

    Silow, Christoph; Zannini, Emanuele; Axel, Claudia; Belz, Markus C. E.; Arendt, Elke K.

    2017-01-01

    Puff pastry is a high-fat bakery product with fat playing a key role, both during the production process and in the final pastry. In this study, response surface methodology (RSM) was successfully used to evaluate puff pastry quality for the development of a fat-reduced version. The technological parameters modified included the level of roll-in fat, the number of fat layers (50–200) and the final thickness (1.0–3.5 mm) of the laminated dough. Quality characteristics of puff pastry were measured using the Texture Analyzer with an attached Extended Craft Knife (ECK) and Multiple Puncture Probe (MPP), the VolScan and the C-Cell imaging system. The number of fat layers and final dough thickness, in combination with the amount of roll-in fat, had a significant impact on the internal and external structural quality parameters. With technological changes alone, a fat-reduced (≥30%) puff pastry was developed. The qualities of fat-reduced puff pastries were comparable to conventional full-fat (33 wt %) products. A sensory acceptance test revealed no significant differences in taste of fatness or ‘liking of mouthfeel’. Additionally, the fat-reduced puff pastry resulted in a significant (p < 0.05) positive correlation to ‘liking of flavor’ and overall acceptance by the assessors. PMID:28231095

  3. Flow behavior of N2 huff and puff process for enhanced oil recovery in tight oil reservoirs.

    PubMed

    Lu, Teng; Li, Zhaomin; Li, Jian; Hou, Dawei; Zhang, Dingyong

    2017-11-16

    In the present work, the potential of N 2 huff and puff process to enhance the recovery of tight oil reservoir was evaluated. N 2 huff and puff experiments were performed in micromodels and cores to investigate the flow behaviors of different cycles. The results showed that, in the first cycle, N 2 was dispersed in the oil, forming the foamy oil flow. In the second cycle, the dispersed gas bubbles gradually coalesced into the continuous gas phase. In the third cycle, N 2 was produced in the form of continuous gas phase. The results from the coreflood tests showed that, the primary recovery was only 5.32%, while the recoveries for the three N 2 huff and puff cycles were 15.1%, 8.53% and 3.22%, respectively.The recovery and the pressure gradient in the first cycle were high. With the increase of huff and puff cycles, and the oil recovery and the pressure gradient rapidly decreased. The oil recovery of N 2 huff and puff has been found to increase as the N 2 injection pressure and the soaking time increased. These results showed that, the properly designed and controlled N 2 huff and puff process can lead to enhanced recovery of tight oil reservoirs.

  4. E-cigarettes generate high levels of aldehydes only in 'dry puff' conditions.

    PubMed

    Farsalinos, Konstantinos E; Voudris, Vassilis; Poulas, Konstantinos

    2015-08-01

    Aldehydes are emitted by electronic cigarettes due to thermal decomposition of liquid components. Although elevated levels have been reported with new-generation high-power devices, it is unclear whether they are relevant to true exposure of users (vapers) because overheating produces an unpleasant taste, called a dry puff, which vapers learn to avoid. The aim was to evaluate aldehyde emissions at different power levels associated with normal and dry puff conditions. Two customizable atomizers were prepared so that one (A1) had a double wick, resulting in high liquid supply and lower chance of overheating at high power levels, while the other (A2) was a conventional setup (single wick). Experienced vapers took 4-s puffs at 6.5 watts (W), 7.5 W, 9 W and 10 W power levels with both atomizers and were asked to report whether dry puffs were generated. The atomizers were then attached to a smoking machine and aerosol was trapped. Clinic office and analytical chemistry laboratory in Greece. Seven experienced vapers. Aldehyde levels were measured in the aerosol. All vapers identified dry puff conditions at 9 W and 10 W with A2. A1 did not lead to dry puffs at any power level. Minimal amounts of aldehydes per 10 puffs were found at all power levels with A1 (up to 11.3 µg for formaldehyde, 4.5 µg for acetaldehyde and 1.0 µg for acrolein) and at 6.5 W and 7.5 W with A2 (up to 3.7 µg for formaldehyde, 0.8 µg for acetaldehyde and 1.3 µg for acrolein). The levels were increased by 30 to 250 times in dry puff conditions (up to 344.6 µg for formaldehyde, 206.3 µg for acetaldehyde and 210.4 µg for acrolein, P < 0.001), while acetone was detected only in dry puff conditions (up to 22.5 µg). Electronic cigarettes produce high levels of aldehyde only in dry puff conditions, in which the liquid overheats, causing a strong unpleasant taste that e-cigarette users detect and avoid. Under normal vaping conditions aldehyde emissions are minimal, even in new-generation high-power e-cigarettes. © 2015 Society for the Study of Addiction.

  5. Comparison of Ecological Momentary Assessment Versus Direct Measurement of E-Cigarette Use With a Bluetooth-Enabled E-Cigarette: A Pilot Study.

    PubMed

    Pearson, Jennifer L; Elmasry, Hoda; Das, Babita; Smiley, Sabrina L; Rubin, Leslie F; DeAtley, Teresa; Harvey, Emily; Zhou, Yitong; Niaura, Raymond; Abrams, David B

    2017-05-29

    Assessing the frequency and intensity of e-cigarette use presents special challenges beyond those posed by cigarette use. Accurate measurement of e-cigarette consumption, puff duration, and the stability of these measures over time will be informative for estimating the behavioral and health effects of e-cigarette use. The purpose of this pilot study was to compare the accuracy of self-reported e-cigarette puff counts collected via ecological momentary assessment (EMA) to objective puff count data collected by a Bluetooth-enabled e-cigarette device and to examine the feasibility and acceptability of using a second-generation e-cigarette among adult smokers. A total of 5 adult smokers were enrolled in a longitudinal parent study assessing how e-cigarette use affects cigarette use among e-cigarette-naïve smokers. Using a text message-based EMA system, participants reported e-cigarette puffs for 2 weeks. Participants were also given a Bluetooth-enabled e-cigarette (Smokio) that passively collected puff counts and puff duration. Comparisons between mean reports of Smokio (device-report) and EMA (self-report) use were evaluated using paired t tests. Correlation and agreement between device- and self-reports were evaluated using Pearson correlation and the concordance correlation coefficient (CCC), respectively. A linear mixed effect model was used to determine the fixed effect of timing and Smokio-reported daily puffs on report accuracy. We examined the relationship between time of day and reporting accuracy using Tukey's test for multiple pairwise comparisons. A total of 5 African American participants, 4 men and 1 woman, who ranged in age from 24 to 59 years completed the study, resulting in 5180 observations (device-report) of e-cigarette use. At baseline, participants reported smoking for 5 to 25 years and consumed a mean of 7 to 13 cigarettes per day (CPD); 4 smoked within 30 minutes of waking. At the 30-day follow-up, CPD range decreased to 1 to 3 cigarettes; 4 participants reported past 7-day e-cigarette use, and 1 participant reported no cigarette smoking in the past 7 days. Over 2 weeks of e-cigarette use, participants took an average of 1074 e-cigarette (SD 779.0) puffs per person as captured by the device reports. Each participant took a mean of 75.0 (SD 58.8) puffs per day, with each puff lasting an average of 3.6 (SD 2.4) seconds. Device reports captured an average of 33.3 (SD 47.8) more puffs per person per day than the self-reported e-cigarette puffs. In 87% of days, participants underestimated the number of puffs they had taken on the Smokio. There was significant moderate correlation (r=.47, P<.001) but poor agreement (p c =0.31, 95% CI 0.15-0.46) between the device- and self-reported data. Reporting accuracy was affected by amount and timing of e-cigarette use. Compared to self-reported e-cigarette use, the Bluetooth-enabled device captured significantly more e-cigarette use and allowed for examination of puff duration in addition to puff counts. A Bluetooth-enabled e-cigarette is a powerful and feasible tool for objective collection of e-cigarette use behavior in the real world. ©Jennifer L Pearson, Hoda Elmasry, Babita Das, Sabrina L Smiley, Leslie F Rubin, Teresa DeAtley, Emily Harvey, Yitong Zhou, Raymond Niaura, David B Abrams. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 29.05.2017.

  6. Comparison of Ecological Momentary Assessment Versus Direct Measurement of E-Cigarette Use With a Bluetooth-Enabled E-Cigarette: A Pilot Study

    PubMed Central

    Elmasry, Hoda; Das, Babita; Smiley, Sabrina L; Rubin, Leslie F; DeAtley, Teresa; Harvey, Emily; Zhou, Yitong; Niaura, Raymond; Abrams, David B

    2017-01-01

    Background Assessing the frequency and intensity of e-cigarette use presents special challenges beyond those posed by cigarette use. Accurate measurement of e-cigarette consumption, puff duration, and the stability of these measures over time will be informative for estimating the behavioral and health effects of e-cigarette use. Objective The purpose of this pilot study was to compare the accuracy of self-reported e-cigarette puff counts collected via ecological momentary assessment (EMA) to objective puff count data collected by a Bluetooth-enabled e-cigarette device and to examine the feasibility and acceptability of using a second-generation e-cigarette among adult smokers. Methods A total of 5 adult smokers were enrolled in a longitudinal parent study assessing how e-cigarette use affects cigarette use among e-cigarette–naïve smokers. Using a text message–based EMA system, participants reported e-cigarette puffs for 2 weeks. Participants were also given a Bluetooth-enabled e-cigarette (Smokio) that passively collected puff counts and puff duration. Comparisons between mean reports of Smokio (device-report) and EMA (self-report) use were evaluated using paired t tests. Correlation and agreement between device- and self-reports were evaluated using Pearson correlation and the concordance correlation coefficient (CCC), respectively. A linear mixed effect model was used to determine the fixed effect of timing and Smokio-reported daily puffs on report accuracy. We examined the relationship between time of day and reporting accuracy using Tukey's test for multiple pairwise comparisons. Results A total of 5 African American participants, 4 men and 1 woman, who ranged in age from 24 to 59 years completed the study, resulting in 5180 observations (device-report) of e-cigarette use. At baseline, participants reported smoking for 5 to 25 years and consumed a mean of 7 to 13 cigarettes per day (CPD); 4 smoked within 30 minutes of waking. At the 30-day follow-up, CPD range decreased to 1 to 3 cigarettes; 4 participants reported past 7-day e-cigarette use, and 1 participant reported no cigarette smoking in the past 7 days. Over 2 weeks of e-cigarette use, participants took an average of 1074 e-cigarette (SD 779.0) puffs per person as captured by the device reports. Each participant took a mean of 75.0 (SD 58.8) puffs per day, with each puff lasting an average of 3.6 (SD 2.4) seconds. Device reports captured an average of 33.3 (SD 47.8) more puffs per person per day than the self-reported e-cigarette puffs. In 87% of days, participants underestimated the number of puffs they had taken on the Smokio. There was significant moderate correlation (r=.47, P<.001) but poor agreement (pc=0.31, 95% CI 0.15-0.46) between the device- and self-reported data. Reporting accuracy was affected by amount and timing of e-cigarette use. Conclusions Compared to self-reported e-cigarette use, the Bluetooth-enabled device captured significantly more e-cigarette use and allowed for examination of puff duration in addition to puff counts. A Bluetooth-enabled e-cigarette is a powerful and feasible tool for objective collection of e-cigarette use behavior in the real world. PMID:28554877

  7. HMS Tonometry Payload

    NASA Image and Video Library

    2012-04-06

    ISS030-E-200591 (6 April 2012) --- In the International Space Station?s Destiny laboratory, NASA astronaut Dan Burbank (left), Expedition 30 commander, uses the Health Maintenance System Tonometry payload to perform an intraocular pressure test on NASA astronaut Don Pettit, flight engineer. The activity was supervised via live Ku-band video by medical ground personnel.

  8. Marshburn performs Tonometry Eye Exam on Hadfield

    NASA Image and Video Library

    2013-01-21

    ISS034-E-035949 (21 Jan. 2013) --- NASA astronaut Tom Marshburn (right), Expedition 34 flight engineer, performs a Tonometry eye exam on Canadian Space Agency astronaut Chris Hadfield, flight engineer, in the Columbus laboratory of the International Space Station. The purpose of this exam is to measure intraocular eye pressure.

  9. Phase-resolved and time-averaged puff motions of an excited stack-issued transverse jet

    NASA Astrophysics Data System (ADS)

    Hsu, C. M.; Huang, R. F.

    2013-07-01

    The dynamics of puff motions in an excited stack-issued transverse jet were studied experimentally in a wind tunnel. The temporal and spatial evolution processes of the puffs induced by acoustic excitation were examined using the smoke flow visualization method and high-speed particle image velocimetry. The temporal and spatial evolutions of the puffs were examined using phase-resolved ensemble-averaged velocity fields and the velocity, length scales, and vorticity characteristics of the puffs were studied. The time-averaged velocity fields were calculated to analyze the velocity distributions and vorticity contours. The results show that a puff consists of a pair of counter-rotating vortex rings. An initial vortex ring was formed due to a concentration of vorticity at the lee side of the issuing jet at the instant of the mid-oscillation cycle. A vortex ring rotating in the opposite direction to that of the initial vortex ring was subsequently formed at the upwind side of the issuing jet. These two counter-rotating vortex rings formed a "mushroom" vortex pair, which was deflected by the crossflow and traveled downstream along a time-averaged trajectory of zero vorticity. The trajectory was situated far above the time-averaged streamline evolving from the leading edge of the tube. The velocity magnitudes of the vortex rings at the upwind and the lee side decreased with time evolution as the puffs traveled downstream due to momentum dissipation and entrainment effects. The puffs traveling along the trajectory of zero vorticity caused large velocities to appear above the leading-edge streamline.

  10. Effect of salt reduction on wheat-dough properties and quality characteristics of puff pastry with full and reduced fat content.

    PubMed

    Silow, Christoph; Zannini, Emanuele; Axel, Claudia; Lynch, Kieran M; Arendt, Elke K

    2016-11-01

    Puff pastry is a major contributor of fat and sodium intake in many countries. The objective of this research was to determine the impact of salt (0-8.4g/100g flour) on the structure and quality characteristics of puff pastry with full and reduced (-40%) fat content as well as the rheological properties of the resulting dough. Therefore, empirical rheological tests were carried out including dough extensibility, dough stickiness and GlutoPeak test. The quality of the puff pastry was characterized with the VolScan, Texture Analyzer and C-Cell. NaCl reduction significantly changed rheological properties of the basic dough as well as a number of major quality characteristics of the puff pastry. Significant differences due to NaCl addition were found in particular for dough resistance, dough stickiness, Peak Maximum Time and Maximum Torque (p<0.05). Peak firmness and total firmness decreased significantly (p<0.05) with increasing salt levels for puff pastry containing full fat. Likewise, maximal lift, specific volume, number of cells and slice brightness increased with increasing NaCl at both fat levels. Although a sensorial comparison of puff pastries revealed that salt reduction (30%) was perceptible, no significant differences were found for all other investigated attributes. Nevertheless, a reduction of 30% salt and 40% fat in puff pastry is achievable as neither the perception and visual impression nor attributes such as volume, firmness and flavour of the final products were significantly affected. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Variability in Puff Topography and Exhaled CO in Waterpipe Tobacco Smoking.

    PubMed

    Kim, Hyoshin; Brinkman, Marielle C; Sharma, Eva; Gordon, Sydney M; Clark, Pamela I

    2016-10-01

    We examined intra-individual variability in puff topography and CO measures collected during laboratory waterpipe (WP) tobacco smoking using a research-grade waterpipe (RWP). WP smoking topography and exhaled CO measures were obtained from 10 established WP smokers in a single-blind, crossover design. Using a previously validated RWP, each participant smoked "Two Apples" WP tobacco ad libitum with a single quick-light charcoal to satiation in 3 laboratory sessions spaced at least one week apart. To examine the intra-individual variability, the intraclass correlation coefficient ( ρ ) for topography and CO measures were estimated. Results: The majority of the topography and CO measures were stable. Most stable were puff frequency ( ρ = 0.88), number of puffs ( ρ = 0.86), and puff duration (ρ = 0.80). Less stable were peak flow ( ρ = 0.57) and total puff volume ( ρ = 0.52). The results provide the first set of empirical evidence that most topography and CO measurements collected using the RWP from a single laboratory smoking session are stable such that they can be representative of a smoker's puffing behaviors and reproducible among 3 sessions spread equally across 3 weeks.

  12. Dynamic OCT measurement of corneal deformation by an air puff in normal and cross-linked corneas

    PubMed Central

    Dorronsoro, Carlos; Pascual, Daniel; Pérez-Merino, Pablo; Kling, Sabine; Marcos, Susana

    2012-01-01

    A new technique is presented for the non-invasive imaging of the dynamic response of the cornea to an air puff inducing a deformation. A spectral OCT instrument combined with an air tonometer in a non-collinear configuration was used to image the corneal deformation over full corneal cross-sections, as well as to obtain high speed measurements of the temporal evolution of the corneal apex. The entire deformation process can be dynamically visualized. A quantitative analysis allows direct extraction of several deformation parameters, such as amplitude, diameter and volume of the maximum deformation, as well as duration and speed of the increasing deformation period and the recovery period. The potential of the technique is demonstrated on porcine corneas in vitro under constant IOP for several conditions (untreated, after riboflavin instillation and under cross-linking with ultraviolet light), as well as on human corneas in vivo. The new technique has proved very sensitive to detect differences in the deformation parameters across conditions. We have confirmed non-invasively that Riboflavin and UV-cross-linking induce changes in the corneal biomechanical properties. Those differences appear to be the result of changes in constituent properties of the cornea, and not a consequence of changes in corneal thickness, geometry or IOP. These measurements are a first step for the estimation of the biomechanical properties of corneal tissue, at an individual level and in vivo, to improve diagnosis and prognosis of diseases and treatments involving changes in the biomechanical properties of the cornea. PMID:22435096

  13. Invited Review Article: Gas puff imaging diagnostics of edge plasma turbulence in magnetic fusion devices

    DOE PAGES

    Zweben, S. J.; Terry, J. L.; Stotler, D. P.; ...

    2017-04-27

    Gas puff imaging (GPI) is a diagnostic of plasma turbulence which uses a puff of neutral gas at the plasma edge to increase the local visible light emission for improved space-time resolution of plasma fluctuations. This paper reviews gas puff imaging diagnostics of edge plasma turbulence in magnetic fusion research, with a focus on the instrumentation, diagnostic cross-checks, and interpretation issues. The gas puff imaging hardware, optics, and detectors are described for about 10 GPI systems implemented over the past similar to 15 years. Comparison of GPI results with other edge turbulence diagnostic results is described, and many common featuresmore » are observed. Here, several issues in the interpretation of GPI measurements are discussed, and potential improvements in hardware and modeling are suggested.« less

  14. Invited Review Article: Gas puff imaging diagnostics of edge plasma turbulence in magnetic fusion devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zweben, S. J.; Terry, J. L.; Stotler, D. P.

    Gas puff imaging (GPI) is a diagnostic of plasma turbulence which uses a puff of neutral gas at the plasma edge to increase the local visible light emission for improved space-time resolution of plasma fluctuations. This paper reviews gas puff imaging diagnostics of edge plasma turbulence in magnetic fusion research, with a focus on the instrumentation, diagnostic cross-checks, and interpretation issues. The gas puff imaging hardware, optics, and detectors are described for about 10 GPI systems implemented over the past similar to 15 years. Comparison of GPI results with other edge turbulence diagnostic results is described, and many common featuresmore » are observed. Here, several issues in the interpretation of GPI measurements are discussed, and potential improvements in hardware and modeling are suggested.« less

  15. Research on plasma-puff initiation of high Coulomb transfer switches

    NASA Technical Reports Server (NTRS)

    Venable, Demetrius D.; Han, Kwang S.

    1993-01-01

    The plasma-puff triggering mechanism based on hypocycloidal pinch geometry was investigated to determine the optimal operating conditions for an azimuthally uniform surface flashover which initiates plasma-puff under wide ranges of fill gas pressures of Ar, He and N2. Research is presented and resulting conference papers are attached. These papers include 'Characteristics of Plasma-Puff Trigger for an Inverse-Pinch Plasma Switch'; 'Ultra-High-Power Plasma Switch INPUTS for Pulse Power Systems'; 'Characteristics of Switching Plasma in an Inverse-Pinch Switch'; 'Comparative Study of INPIStron and Spark Gap'; and 'INPIStron Switched Pulsed Power for Dense Plasma Pinches.'

  16. Studies of the Plasma Triggering Mechanism of Inverse Pinch Switch

    DTIC Science & Technology

    1993-11-10

    plasma - focus driven plasma-puff was also discussed in comparison with the hypocycloidal pinch plasma-puff triggering. The main discharge of inverse pinch switch with plasma - focus driven plasma-puff trigger is found to be more azimuthally uniform than that with hypocycloidal pinch plasma-puff trigger in a gas pressure region between 80 mTorr and 1 Torr. A comparative study of the INPIStron and a spark gap also reveals that the INPIStron with a low impedance Z = 9 ohms can transfer a high voltage pulse with a superior pulse-shape fidelity over that with

  17. Differing ERP patterns caused by suction and puff stimuli.

    PubMed

    Choi, Mi-Hyun; Kim, Hyung-Sik; Baek, Ji-Hye; Lee, Jung-Chul; Park, Sung-Jun; Jeong, Ul-Ho; Gim, Seon-Young; You, Ji Hye; Kim, Sung-Pil; Lim, Dae-Woon; Kim, Hyun-Jun; Chung, Soon-Cheol

    2015-05-06

    The present study compared event-related potential (ERP) patterns for two stimuli types, puff and suction, by applying these stimuli to the fingers; ERP patterns for the two stimuli were compared at C3, an area related to somatosensory perception, and at FC5, an area related to motor function. Participants were 12 healthy males in their 20s (mean age=23.1±2.0 years). One session consisted of a Control Phase (3s), a Stimulation Phase (3s), and a Rest Phase (9s). During the Stimulation Phase, a 4-psi suction or puff stimulus was applied to the first joint of the right index finger. After completion of the session, a subjective magnitude test was presented. In all phases, electroencephalography signals were recorded. We extracted maximum positive amplitude and minimum negative amplitude as well as relevant latency values for C3 and FC5 signals. Suction and puff stimuli had similar subjective magnitude scores. For both C3 and FC5, the maximum and minimum amplitude latency was reached earlier for the suction stimulus than for the puff stimulus. In conclusion, when suction and puff stimuli of the same intensity were applied to the fingers, the suction stimulus caused a more sensitive response in the somatosensory area (C3) and motor area (FC5) than did the puff stimulus. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. PECASE - Multi-Scale Experiments and Modeling in Wall Turbulence

    DTIC Science & Technology

    2014-12-23

    transition to turbulence in pipe flow have been characterized by the creation of puffs and slugs [Wygnanski and Champagne , 1973]. Puffs have been identified...Fluid Mech., 568:55–76, 2006. I. J. Wygnanski and F. H. Champagne . On transition in a pipe. Part 1: The origin of puffs and slugs and the flow in a

  19. Disruption of trace conditioning of the nictitating membrane response in rabbits by central cholinergic blockade.

    PubMed

    Kaneko, T; Thompson, R F

    1997-05-01

    Central muscarinic cholinergic involvement in classical conditioning of eyeblink responses was determined in trace and delay paradigms. Rabbits were trained on a trace procedure in which a 250-ms tone conditioned stimulus (CS) and a 100-ms air-puff unconditioned stimulus (UCS) were presented with a 500-ms trace interval. Each training session day consisted of ten tone alone, ten air-puff alone and 80 paired CS-UCS trials. Scopolamine hydrochloride at doses of 0.03 and 0.1 mg/0.5 ml per kg, s.c. dose-dependently disrupted acquisition of conditioned responses. Rabbits that were treated with scopolamine and failed to learn showed a gradual increase in conditioned responses during an additional training period with saline injections and no transfer from earlier training. Scopolamine methyl bromide, which does not appreciably cross the blood-brain barrier, showed no effects in the trace conditioning paradigm at a dose of 0.1 mg/kg, s.c., indicating central cholinergic blockade is responsible for the suppressive effect of scopolamine. Scopolamine hydrochloride at a dose of 0.1 mg/kg, s.c. did not block acquisition in the delay procedure with a 250-ms inter-stimulus interval, although the rate of acquisition was somewhat reduced by the drug. These data are the first to demonstrate that classical conditioning of the eyeblink response in the trace procedure is highly sensitive to central cholinergic deficits.

  20. 8A.03: CONTINUOUS MONITORING OF HEMODYNAMICS IN THE SHORT ARM HUMAN CENTRIFUGE: A FEASIBILITY STUDY.

    PubMed

    Londono, F; Uytterhaegen, B; Kassel, R; Vanraemdonck, R; Beck, A; Comet, B; Runge, A; Segers, P

    2015-06-01

    The aim was to test the technical feasibility of a set up combining tonometry and ultrasound, designated as Continuous Physiological and Medical Monitoring (CPMM), for cardiovascular assessment on humans and to evaluate the ability to assess physiological changes induced by artificial gravity in the short arm human centrifuge (SAHC, Verhaert, Belgium) for detecting and preventing potential disorders induced by weightlessness. The project was developed under an European Space Agency (ESA) contract (4000101988/10/NL/EM) and with its support, by the company Verhaert in consortium with the Institute for Space Medicine and Physiology (MEDES) and Ghent University. Measurements were performed at MEDES facilities in 4 young (presumably) healthy volunteers (3 males). For two volunteers, the protocol was divided in three periods: acceleration, steady rotation velocity and deceleration, obtaining carotid pulsed wave (PW)-Mode ultrasound sequences. For another volunteer (female), carotid PW-Mode ultrasound images and brachial and radial tonometry signals were acquired at baseline and during steady rotation. For the fourth volunteer, carotid and femoral PW-Mode ultrasound images and brachial, radial and carotid tonometry signals were acquired at baseline and during an initial (velocity1) and a following faster (velocity2) rotation velocity (see figure on the following page). Carotid PW-Mode ultrasound imaging was obtained in all 4 volunteers during different steps of the protocol. Femoral ultrasound imaging presented more difficulties related mainly to the placement of the probe after baseline, even if in one case results were feasible. Tonometry was, generally, a bigger challenge due to the intrinsic sensitivity of the method. Overall, radial artery tonometry provided the best results, while brachial artery results were acceptable only in one occasion. Carotid tonometry was measured only for one subject with suitable results for processing. Tonometry measurements were feasible under a spin velocity limit, while PW-Mode ultrasound images were more robust and stable. Although general conclusions must be supported by a larger sample, suitable signals and locations were identified and a user friendly and mobile set-up was tested successfully and it is available for further research to identified and assess mechanisms and reflexes acting in physiological adaptation to various gravity conditions.(Figure is included in full-text article.).

  1. Preliminary Results of an Examination of Electronic Cigarette User Puff Topography: The Effect of a Mouthpiece-Based Topography Measurement Device on Plasma Nicotine and Subjective Effects

    PubMed Central

    Spindle, Tory R.; Breland, Alison B.; Karaoghlanian, Nareg V.; Shihadeh, Alan L.

    2015-01-01

    Introduction: Electronic cigarettes (ECIGs) heat a nicotine-containing solution; the resulting aerosol is inhaled by the user. Nicotine delivery may be affected by users’ puffing behavior (puff topography), and little is known about the puff topography of ECIG users. Puff topography can be measured using mouthpiece-based computerized systems. However, the extent to which a mouthpiece influences nicotine delivery and subjective effects in ECIG users is unknown. Methods: Plasma nicotine concentration, heart rate, and subjective effects were measured in 13 experienced ECIG users who used their preferred ECIG and liquid (≥12mg/ml nicotine) during 2 sessions (with or without a mouthpiece). In both sessions, participants completed an ECIG use session in which they were instructed to take 10 puffs with 30-second inter-puff intervals. Puff topography was recorded in the mouthpiece condition. Results: Almost all measures of the effects of ECIG use were independent of topography measurement. Collapsed across session, mean plasma nicotine concentration increased by 16.8ng/ml, and mean heart rate increased by 8.5 bpm (ps < .05). Withdrawal symptoms decreased significantly after ECIG use. Participants reported that the mouthpiece affected awareness and made ECIG use more difficult. Relative to previously reported data for tobacco cigarette smokers using similar topography measurement equipment, ECIG-using participants took larger and longer puffs with lower flow rates. Conclusions: In experienced ECIG users, measuring ECIG topography did not influence ECIG-associated nicotine delivery or most measures of withdrawal suppression. Topography measurement systems will need to account for the low flow rates observed for ECIG users. PMID:25239957

  2. Preliminary results of an examination of electronic cigarette user puff topography: the effect of a mouthpiece-based topography measurement device on plasma nicotine and subjective effects.

    PubMed

    Spindle, Tory R; Breland, Alison B; Karaoghlanian, Nareg V; Shihadeh, Alan L; Eissenberg, Thomas

    2015-02-01

    Electronic cigarettes (ECIGs) heat a nicotine-containing solution; the resulting aerosol is inhaled by the user. Nicotine delivery may be affected by users' puffing behavior (puff topography), and little is known about the puff topography of ECIG users. Puff topography can be measured using mouthpiece-based computerized systems. However, the extent to which a mouthpiece influences nicotine delivery and subjective effects in ECIG users is unknown. Plasma nicotine concentration, heart rate, and subjective effects were measured in 13 experienced ECIG users who used their preferred ECIG and liquid (≥ 12 mg/ml nicotine) during 2 sessions (with or without a mouthpiece). In both sessions, participants completed an ECIG use session in which they were instructed to take 10 puffs with 30-second inter-puff intervals. Puff topography was recorded in the mouthpiece condition. Almost all measures of the effects of ECIG use were independent of topography measurement. Collapsed across session, mean plasma nicotine concentration increased by 16.8 ng/ml, and mean heart rate increased by 8.5 bpm (ps < .05). Withdrawal symptoms decreased significantly after ECIG use. Participants reported that the mouthpiece affected awareness and made ECIG use more difficult. Relative to previously reported data for tobacco cigarette smokers using similar topography measurement equipment, ECIG-using participants took larger and longer puffs with lower flow rates. In experienced ECIG users, measuring ECIG topography did not influence ECIG-associated nicotine delivery or most measures of withdrawal suppression. Topography measurement systems will need to account for the low flow rates observed for ECIG users. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. The Influence of Puff Characteristics, Nicotine Dependence, and Rate of Nicotine Metabolism on Daily Nicotine Exposure in African American Smokers.

    PubMed

    Ross, Kathryn C; Dempsey, Delia A; St Helen, Gideon; Delucchi, Kevin; Benowitz, Neal L

    2016-06-01

    African American (AA) smokers experience greater tobacco-related disease burden than Whites, despite smoking fewer cigarettes per day (CPD). Understanding factors that influence daily nicotine intake in AA smokers is an important step toward decreasing tobacco-related health disparities. One factor of interest is smoking topography, or the study of puffing behavior. (i) to create a model using puff characteristics, nicotine dependence, and nicotine metabolism to predict daily nicotine exposure, and (ii) to compare puff characteristics and nicotine intake from two cigarettes smoked at different times to ensure the reliability of the puff characteristics included in our model. Sixty AA smokers smoked their preferred brand of cigarette at two time points through a topography device. Plasma nicotine, expired CO, and changes in subjective measures were measured before and after each cigarette. Total nicotine equivalents (TNE) was measured from 24-hour urine collected during ad libitum smoking. In a model predicting daily nicotine exposure, total puff volume, CPD, sex, and menthol status were significant predictors (R(2) = 0.44, P < 0.001). Total puff volume was significantly greater and inter-puff intervals were significantly shorter after ad lib smoking compared with the first cigarette of the day, but puffing behaviors for both cigarettes were highly correlated (r range = 0.69-0.89, P < 0.001) within-subjects. This is the first study, to our knowledge, to show that puff characteristics of individual cigarettes are predictive of daily nicotine intake. These findings enhance our understanding of the relationship between smoking behavior and nicotine intake in AA smokers. Cancer Epidemiol Biomarkers Prev; 25(6); 936-43. ©2016 AACR. ©2016 American Association for Cancer Research.

  4. Enhancing the x-ray output of a single-wire explosion with a gas-puff based plasma opening switch

    NASA Astrophysics Data System (ADS)

    Engelbrecht, Joseph T.; Ouart, Nicholas D.; Qi, Niansheng; de Grouchy, Philip W.; Shelkovenko, Tatiana A.; Pikuz, Sergey A.; Banasek, Jacob T.; Potter, William M.; Rocco, Sophia V.; Hammer, David A.; Kusse, Bruce R.; Giuliani, John L.

    2018-02-01

    We present experiments performed on the 1 MA COBRA generator using a low density, annular, gas-puff z-pinch implosion as an opening switch to rapidly transfer a current pulse into a single metal wire on axis. This gas-puff on axial wire configuration was studied for its promise as an opening switch and as a means of enhancing the x-ray output of the wire. We demonstrate that current can be switched from the gas-puff plasma into the wire, and that the timing of the switch can be controlled by the gas-puff plenum backing pressure. X-ray detector measurements indicate that for low plenum pressure Kr or Xe shots with a copper wire, this configuration can offer a significant enhancement in the peak intensity and temporal distribution of radiation in the 1-10 keV range.

  5. Effect of e-liquid flavor on electronic cigarette topography and consumption behavior in a 2-week natural environment switching study.

    PubMed

    Robinson, R J; Hensel, E C; Al-Olayan, A A; Nonnemaker, J M; Lee, Y O

    2018-01-01

    Electronic Nicotine Delivery Systems (ENDS) offer an alternate means to consume nicotine in a variety of flavored aerosols. Data are needed to better understand the impact of flavors on use behavior. A natural environment observational study was conducted on experienced ENDS users to measure the effect of e-liquid flavor on topography and consumption behavior. The RIT wPUMTM monitor was used to record to record the date and time and puff topography (flow rate, volume, duration) for every puff taken by N = 34 participants over the course of two weeks. All participants used tobacco flavor for one week, and either berry or menthol flavor for one week. Results provide strong evidence that flavor affects the topography behaviors of mean puff flow rate and mean puff volume, and there is insufficient evidence to support an influence of flavor on mean puff duration and mean puff interval. There was insufficient evidence, due to the low power associated with the limited number of observation days, to establish a relationship between flavor and cumulative consumption behavior. While the results indicate that an effect may be evident, additional observation days are required to establish significance.

  6. Effect of e-liquid flavor on electronic cigarette topography and consumption behavior in a 2-week natural environment switching study

    PubMed Central

    al-Olayan, A. A.; Nonnemaker, J. M.; Lee, Y. O.

    2018-01-01

    Electronic Nicotine Delivery Systems (ENDS) offer an alternate means to consume nicotine in a variety of flavored aerosols. Data are needed to better understand the impact of flavors on use behavior. A natural environment observational study was conducted on experienced ENDS users to measure the effect of e-liquid flavor on topography and consumption behavior. The RIT wPUMTM monitor was used to record to record the date and time and puff topography (flow rate, volume, duration) for every puff taken by N = 34 participants over the course of two weeks. All participants used tobacco flavor for one week, and either berry or menthol flavor for one week. Results provide strong evidence that flavor affects the topography behaviors of mean puff flow rate and mean puff volume, and there is insufficient evidence to support an influence of flavor on mean puff duration and mean puff interval. There was insufficient evidence, due to the low power associated with the limited number of observation days, to establish a relationship between flavor and cumulative consumption behavior. While the results indicate that an effect may be evident, additional observation days are required to establish significance. PMID:29718974

  7. Numerical and clinical investigation on the material model of the cornea in Corvis tonometry tests: differentiation between hyperelasticity and viscoelasticity

    NASA Astrophysics Data System (ADS)

    Jannesari, Mohammad; Mosaddegh, Peiman; Kadkhodaei, Mahmoud; Kasprzak, Henryk; Jabbarvand Behrouz, Mahmoud

    2018-05-01

    Non-contact tonometers, including ORA and Corvis ST, are not only used to estimate intraocular pressure (IOP) in clinical surveys but are also utilized to evaluate biomechanical properties of the cornea or anterior eye. However, for the cornea a realistic material model is still a controversial issue, and the main goal of the present study is to make this clearer. To this aim, the corneal biomechanical response is modeled by using a four-element linear viscoelastic model, which is characterized by in-vivo clinical data from Corvis ST tonometer. IOP tonometry tests on 5 normal and 5 keratoconic cases are accomplished by Corvis ST tonometer. Images from cornea deformation due to applied air jet are acquired from Corvis ST and are converted to the corneal deformation profiles by image processing techniques. By excluding the eye globe rigid body motion (retraction) from the total eye displacement, pure deformation of the cornea is obtained and used to calculate the required material properties. By calculating retardation time, contribution of the material viscosity during the test is estimated. The results show that viscosity effects do not substantially contribute to the cornea response during dynamic tests for both normal and keratoconic corneas. Indeed, the viscous effect comes from the eye globe rigid body motion.

  8. Puff and bite: the relationship between the glucocorticoid stress response and anti-predator performance in checkered puffer (Sphoeroides testudineus).

    PubMed

    Cull, Felicia; O'Connor, Constance M; Suski, Cory D; Shultz, Aaron D; Danylchuk, Andy J; Cooke, Steven J

    2015-04-01

    Individual variation in the endocrine stress response has been linked to survival and performance in a variety of species. Here, we evaluate the relationship between the endocrine stress response and anti-predator behaviors in wild checkered puffers (Sphoeroides testudineus) captured at Eleuthera Island, Bahamas. The checkered puffer has a unique and easily measurable predator avoidance strategy, which is to inflate or 'puff' to deter potential predators. In this study, we measured baseline and stress-induced circulating glucocorticoid levels, as well as bite force, a performance measure that is relevant to both feeding and predator defence, and 'puff' performance. We found that puff performance and bite force were consistent within individuals, but generally decreased following a standardized stressor. Larger puffers were able to generate a higher bite force, and larger puffers were able to maintain a more robust puff performance following a standardized stressor relative to smaller puffers. In terms of the relationship between the glucocorticoid stress response and performance metrics, we found no relationship between post-stress glucocorticoid levels and either puff performance or bite force. However, we did find that baseline glucocorticoid levels predicted the ability of a puffer to maintain a robust puff response following a repeated stressor, and this relationship was more pronounced in larger individuals. Our work provides a novel example of how baseline glucocorticoids can predict a fitness-related anti-predator behavior. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Make your own cigarettes: toxicant exposure, smoking topography, and subjective effects.

    PubMed

    Koszowski, Bartosz; Rosenberry, Zachary R; Viray, Lauren C; Potts, Jennifer L; Pickworth, Wallace B

    2014-09-01

    Despite considerable use of make your own (MYO) cigarettes worldwide and increasing use in the United States, relatively little is known about how these cigarettes are smoked and the resultant toxicant exposure. In a laboratory study, we compared two types of MYO cigarettes-roll your own (RYO) and personal machine made (PMM)-with factory-made (FM) cigarettes in three groups of smokers who exclusively used RYO (n = 34), PMM (n = 23), or FM (n = 20). Within each group, cigarettes were smoked in three conditions: (i) after confirmed overnight tobacco abstinence; (ii) in an intense smoking paradigm; and (iii) without restrictions. All cigarettes were smoked ad lib through a smoking topography unit. Plasma nicotine significantly increased after cigarettes in all conditions except PMM in the intense smoking paradigm. Puff volume, puff duration, total puff volume, and puff velocity did not differ between cigarette types but the puffs per cigarette and time to smoke were significantly smaller for RYO compared with PMM and FM. Regardless of the cigarette, participants consumed the first three puffs more vigorously than the last three puffs. Despite the belief of many of their consumers, smoking MYO cigarettes is not a safe alternative to FM cigarettes. Like FM, MYO cigarettes expose their users to harmful constituents of tobacco smoke. Despite differences in size and design their puffing profiles are remarkably similar. These data are relevant to health and regulatory considerations on the MYO cigarettes. ©2014 American Association for Cancer Research.

  10. Are glass fiber particles released during the use of electronic cigarettes? Development of a semi-quantitative approach to detect glass particle emission due to vaping.

    PubMed

    Shin, Jae-Won; Jo, Sang-Hee; Kim, Ki-Hyun; Song, Hee-Nam; Kang, Chang-Hee; Bolan, Nanthi; Hong, Jongki

    2018-05-04

    This study investigated the emission characteristics of glass particles resulting from smoking electronic cigarettes (ECs). First, the most suitable filter for the collection of glass particles was explored by examining the performance (reliability) of various types of filters. A polycarbonate filter was determined as the optimum choice to collect glass particles in EC aerosol. A cartomizer was filled with EC refill solution composed of an equal volume of propylene glycol (PG) and vegetable glycol (VG). To simulate the potential conditions for glass particle emission, EC vaped aerosols were collected at three distinctive puffing intervals: (1) 0-10 puffs, (2) 101-110 puffs, and (3) 201-210 puffs (flow rate of 1 L min -1 , 2 s per puff, and 10 puffs per sample). Glass particles were observed as early as after 100 times puffing from certain products, while after 200 from others. Thus, glass particles were generated by increasing the number of puffs and usage of the EC cartomizer. The analysis of glass particles collected onto polycarbonate filters by scanning electron microscopy (SEM)/energy dispersive X-ray spectroscopy (EDS) confirmed the presence of glass particles in samples collected after puffing 100-200 times. The study demonstrated that the possibility of glass particle emissions from the EC device increased considerably with the increasing number of total puffs. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Control of IP3-mediated Ca2+ puffs in Xenopus laevis oocytes by the Ca2+-binding protein parvalbumin

    PubMed Central

    John, Linu M; Mosquera-Caro, Monica; Camacho, Patricia; Lechleiter, James D

    2001-01-01

    Elementary events of Ca2+ release (Ca2+ puffs) can be elicited from discrete clusters of inositol 1,4,5 trisphosphate receptors (IP3Rs) at low concentrations of IP3. Ca2+ puffs have rarely been observed unless elicited by either hormone treatment or introduction of IP3 into the cell. However, cells appear to have sufficient concentrations of IP3 (0.1-3.0 μM) to induce Ca2+ release under resting conditions. Here, we investigated Ca2+ puff activity in non-stimulated Xenopus oocytes using confocal microscopy. The fluorescent Ca2+ dye indicators Calcium Green 1 and Oregon Green 488 BAPTA-2 were injected into oocytes to monitor basal Ca2+ activity. In this preparation, injection or overexpression of parvalbumin, an EF-hand Ca2+-binding protein (CaBP), induced Ca2+ puffs in resting Xenopus oocytes. This activity was inhibited by heparin, an IP3R channel blocker, and by mutation of the Ca2+-binding sites in parvalbumin. Ca2+ puff activity was also evoked by injection of low concentrations of the Ca2+ chelator EGTA, but not by calbindin D28k, another member of the EF-hand CaBP superfamily. BAPTA and the Ca2+ indicator dye Oregon Green 488 BAPTA-1 evoked Ca2+ puff activity, while the dextran conjugate of Oregon Green 488 BAPTA-1 did not. These data indicate that a Ca2+ buffer must be mobile in order to increase Ca2+ puff activity. Together, the data indicate that some IP3Rs spontaneously release Ca2+ under resting concentrations of IP3. These elementary Ca2+ events appear to be below the level of detection of current imaging techniques. We suggest that parvalbumin evokes Ca2+ puffs by coordinating the activity of elementary IP3R channel openings. We conclude that Ca2+ release can be evoked not only by hormone-induced increases in IP3, but also by expression of mobile cytosolic CaBPs under resting concentrations of IP3. PMID:11507154

  12. Influence of pre-drying treatments on physicochemical and organoleptic properties of explosion puff dried jackfruit chips.

    PubMed

    Yi, Jianyong; Zhou, Linyan; Bi, Jinfeng; Chen, Qinqin; Liu, Xuan; Wu, Xinye

    2016-02-01

    The effects of hot air drying (AD), freeze drying (FD), infrared drying (IR), microwave drying (MV), vacuum drying (VD) as pre-drying treatments for explosion puff drying (EPD) on qualities of jackfruit chips were studied. The lowest total color differences (∆E) were found in the FD-, MV- and VD-EPD dried chips. Volume expansion effect (9.2 %) was only observed in the FD-EPD dried chips, which corresponded to its well expanded honeycomb microstructures and high rehydration rate. Compared with AD-, IR-, MV- and VD-EPD, the FD-EPD dried fruit chips exhibited lower hardness and higher crispness, indicative of a crispier texture. FD-EPD dried fruits also obtained high retentions of ascorbic acid, phenolics and carotenoids compared with that of the other puffed products. The results of sensory evaluation suggested that the FD-EPD was a more beneficial combination because it enhanced the overall qualities of jackfruit chips. In conclusion, the FD-EPD could be used as a novel combination drying method for processing valuable and/or high quality fruit chips.

  13. The Experimental Study of Characterized Noble Gas Puffs Irradiated by Ultra-Short Laser Pulses Compared with X-Pinches as an X-Ray Source

    NASA Astrophysics Data System (ADS)

    Schultz, Kimberly Ann

    The goal of this dissertation is to study the basic physics and X-ray emission (1-10 keV) of two X-ray sources: X-pinch plasmas and a clustered gas-puff irradiated by an ultrashort laser pulse. X-pinches and other typical X-ray sources using solid targets create hot debris that can damage sensitive equipment. Therefore, to perform sensitive backlighting or X-ray effects testing, debris-free sources of radiation must be investigated. In this work, the author presents a broad study of clustered noble gas puffs including characterization measurements and laser heating experiments using several gas nozzles and multiple gases. Ultimately, the goal is to compare the laser-irradiated gas-puff and X-pinch plasmas as X-ray sources. Characterization of the gas puffs is performed at the Radiation Physics Laboratory at the University of Nevada, Reno (UNR) Physics Department using optical interferometry and Rayleigh scattering to determine density and cluster radius. By changing the gas-puff variables control of both the density and cluster size of the gas jets is obtained. Two laser systems provide the high intensities desired for the laser-irradiated gas puff experiments: the UNR Leopard Laser (1-2x1019 W/cm2) and the Lawrence Livermore National Laboratory's Titan Laser (7x1019 W/cm2). X-ray emission is studied as a function of laser pulse parameters, gas target type, gas puff density, and the gas-delay timing between puff initiation and laser interaction with the puff. The tested gases are Ar, Kr, Xe, and four mixtures of the noble gases. Time-resolved X-ray measurements are captured with Silicon diodes and photoconducting diamond detectors. Electron beam detectors include Faraday cups and a high-energy (> 1 MeV) electron spectrometer. Modeling of spectra from X-ray crystal spectrometers provides plasma density and temperature measurement and a molecular dynamics (MD) code describes cluster interactions with the laser pulse. The conversion of laser energy into X rays is also measured. Laser beam transmission through and absorption by the gas puff reveal the complexity of using laser-irradiated gas puffs as X-ray sources. A strong anisotropy of X-ray and electron emissions were observed at both laser facilities. X-pinch plasmas can provide intense hard X rays and strong electron beams originating from small sources with many applications. Recent research has been conducted into four-wire X-pinches at the UNR Zebra machine, a 1-MA pulsed power generator. Two different wire materials are considered in this study, Ag and Mo. We observe a relatively linear correlation between load mass and implosion time for Mo X-pinches; in fact, this relationship also extends to include Ag. Interestingly, X-ray burst features drastically change in shape when the load mass is varied. Advantages of laser-irradiated gas puffs include a lack of damaging debris, high repetition rate, and ease of control. Its disadvantages include its inefficiency at converting electrical energy to X-rays, which is mostly limited by laser efficiency, and relatively low total energy yield. X-pinches, on the other hand, produced kJ of energy in a broad spectral region. However, they create a large amount of debris, have a low repetition rate, and, at 1-MA, have hard-to-predict implosion times.

  14. Group Waterpipe Tobacco Smoking Increases Smoke Toxicant Concentration.

    PubMed

    Ramôa, Carolina P; Shihadeh, Alan; Salman, Rola; Eissenberg, Thomas

    2016-05-01

    Waterpipe tobacco smoking is a global health concern. Laboratory research has focused on individual waterpipe users while group use is common. This study examined user toxicant exposure and smoke toxicant yield associated with individual and group waterpipe smoking. Twenty-two pairs of waterpipe smokers used a waterpipe individually and as a dyad. Before and after smoking, blood was sampled and expired carbon monoxide (CO) measured; puff topography was recorded throughout. One participant from each pair was selected randomly and their plasma nicotine and expired air CO concentrations were compared when smoking alone to when smoking as part of a dyad. Recorded puff topography was used to machine-produce smoke that was analyzed for toxicant content. There was no difference in mean plasma nicotine concentration when an individual smoked as part of a dyad (mean = 14.9 ng/ml; standard error of the mean [SEM] = 3.0) compared to when smoking alone (mean = 10.0 ng/ml; SEM = 1.5). An individual smoking as part of as a dyad had, on average, lower CO (mean = 15.8 ppm; SEM = 2.0) compared to when smoking alone (mean= 21.3 ppm; SEM = 2.7). When two participants smoked as a dyad they took, on average, more puffs (mean = 109.8; SEM = 7.6) than a singleton smoker (mean = 77.7; SEM = 8.1) and a shorter interpuff interval (IPI; dyad mean = 23.8 seconds; SEM = 1.9; singleton mean = 40.8 seconds; SEM = 4.8). Higher concentrations of several toxicants were observed in dyad-produced smoke. Dyad smoking may increase smoke toxicant content, likely due to the dyad's shorter IPIs and greater puff number. More work is needed to understand if group waterpipe smoking alters the health risks of waterpipe tobacco smoking. This study is the first to measure toxicants in smoke generated from a waterpipe when used by a dyad. Relative to smoke generated by a singleton, dyad smoke had higher concentration of some toxicants. These differences may be attributed to differences in puffing behavior, specifically the shorter IPI and greater puff number observed in the dyad condition. Relative to singleton smokers, dyad smokers were exposed to less CO, but nicotine exposure did not differ. More work is needed to assess the health effects of inhalation of more toxicant-laden smoke during group waterpipe use. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Plasma Radiation Source on the Basis of the Gas Puff with Outer Plasma Shell in the Circuit of a Mega-Ampere Load Current Doubler

    NASA Astrophysics Data System (ADS)

    Kokshenev, V. A.; Labetsky, A. Yu.; Shishlov, A. V.; Kurmaev, N. E.; Fursov, F. I.; Cherdizov, R. K.

    2017-12-01

    Characteristics of Z-pinch plasma radiation in the form of a double shell neon gas puff with outer plasma shell are investigated in the microsecond implosion mode. Experiments are performed using a GIT-12 mega-joule generator with load current doubler having a ferromagnetic core at implosion currents up to 5 MA. Conditions for matching of the nonlinear load with the mega-ampere current multiplier circuit are determined. The load parameters (plasma shell characteristics and mass and geometry of gas puff shells) are optimized on the energy supplied to the gas puff and n energy characteristics of radiation. It is established that the best modes of K-shell radiation in neon are realized for such radial distribution of the gas-puff material at which the compression velocity of the shell is close to a constant and amounts to 27-30 cm/μs. In these modes, up to 40% of energy supplied to the gas puff is converted into K-shell radiation. The reasons limiting the efficiency of the radiation source with increasing implosion current are analyzed. A modernized version of the energy supply from the current doubler to the Z-pinch is proposed.

  16. Nicotine Delivery and Vaping Behavior During ad Libitum E-cigarette Access.

    PubMed

    St Helen, Gideon; Ross, Kathryn C; Dempsey, Delia A; Havel, Christopher M; Jacob, Peyton; Benowitz, Neal L

    2016-10-01

    To characterize vaping behavior and nicotine intake during ad libitum e-cigarette access. Thirteen adult e-cigarette users had 90 minutes of videotaped ad libitum access to their usual e-cigarette. Plasma nicotine was measured before and every 15 minutes after the first puff; subjective effects were measured before and after the session. Average puff duration and interpuff interval were 3.5±1.4 seconds (±SD) and 118±141 seconds, respectively. 12% of puffs were unclustered puffs while 43%, 28%, and 17% were clustered in groups of 2-5, 6-10, and >10 puffs, respectively. On average, 4.0±3.3 mg of nicotine was inhaled; the maximum plasma nicotine concentration (C max ) was 12.8±8.5 ng/mL. Among the 8 tank users, number of puffs was positively correlated with amount of nicotine inhaled, C max , and area under the plasma nicotine concentration-time curve (AUC 0 → 90min ) while interpuff interval was negatively correlated with C max and AUC 0 → 90 . Vaping patterns differ from cigarette smoking. Plasma nicotine levels were consistent with intermittent dosing of nicotine from e-cigarettes compared to the more bolus dosing from cigarettes. Differences in delivery patterns and peak levels of nicotine achieved could influence the addictiveness of e-cigarettes compared to conventional cigarettes.

  17. Panic Attack History and Smoking Topography

    PubMed Central

    Farris, Samantha G.; Brown, Lily A.; Goodwin, Renee D.; Zvolensky, Michael J.

    2016-01-01

    Background Little is known about panic attacks and puffing topography, a behavioral index of the value of smoking reinforcement. This study examined smoking style during the course of smoking of a single cigarette among adult daily smokers with and without a history of panic attacks. Method Participants (n = 124, Mage = 43.9, SD = 9.7; 44.4% female) were non-treatment seeking daily smokers. Lifetime panic attack history was assessed via diagnostic assessment; 28.2% (n = 35) of the sample had a panic attack history. Participants smoked one cigarette during an ad libitum smoking trial. Puff volume, duration, and inter-puff interval were measured using the Clinical Research Support System (CReSS) pocket device. Results Regression analyses revealed that panic attack status was not associated with significant differences in average puff volume, duration, or inter-puff interval. Multi-level modeling was used to examine puffing trajectories. Puff-level data revealed that there was a significant quadratic time x panic effect for puff volume and duration. Those with a panic attack history demonstrated relatively sustained levels of both puff volume and duration over time, whereas those without a history of panic attacks demonstrated an increase followed by a decrease in volume and duration over time. These effects were not accounted for by the presence of general psychopathology. Discussion Smokers with a panic attack history demonstrate more persistent efforts to self-regulate the delivery of nicotine, and thus may be at risk for continued smoking and dependence. Tailored treatment may be needed to address unique vulnerabilities among this group. PMID:28033542

  18. Panic attack history and smoking topography.

    PubMed

    Farris, Samantha G; Brown, Lily A; Goodwin, Renee D; Zvolensky, Michael J

    2017-02-01

    Little is known about panic attacks and puffing topography, a behavioral index of the value of smoking reinforcement. This study examined smoking style during the course of smoking of a single cigarette among adult daily smokers with and without a history of panic attacks. Participants (n=124, M age =43.9, SD=9.7; 44.4% female) were non-treatment seeking daily smokers. Lifetime panic attack history was assessed via diagnostic assessment; 28.2% (n=35) of the sample had a panic attack history. Participants smoked one cigarette during an ad libitum smoking trial. Puff volume, duration, and inter-puff interval were measured using the Clinical Research Support System (CReSS) pocket device. Regression analyses revealed that panic attack status was not associated with significant differences in average puff volume, duration, or inter-puff interval. Multi-level modeling was used to examine puffing trajectories. Puff-level data revealed that there was a significant quadratic time x panic effect for puff volume and duration. Those with a panic attack history demonstrated relatively sustained levels of both puff volume and duration over time, whereas those without a history of panic attacks demonstrated an increase followed by a decrease in volume and duration over time. These effects were not accounted for by the presence of general psychopathology. Smokers with a panic attack history demonstrate more persistent efforts to self-regulate the delivery of nicotine, and thus may be at risk for continued smoking and dependence. Tailored treatment may be needed to address unique vulnerabilities among this group. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Marijuana and tobacco cigarettes: Estimating their behavioral economic relationship using purchasing tasks.

    PubMed

    Peters, Erica N; Rosenberry, Zachary R; Schauer, Gillian L; O'Grady, Kevin E; Johnson, Patrick S

    2017-06-01

    Although marijuana and tobacco are commonly coused, the nature of their relationship has not been fully elucidated. Behavioral economics has characterized the relationship between concurrently available commodities but has not been applied to marijuana and tobacco couse. U.S. adults ≥18 years who coused marijuana and tobacco cigarettes were recruited via Mechanical Turk, a crowdsourcing service by Amazon. Participants (N = 82) completed online purchasing tasks assessing hypothetical marijuana or tobacco cigarette puff consumption across a range of per-puff prices; 2 single-commodity tasks assessed these when only 1 commodity was available, and 2 cross-commodity tasks assessed these in the presence of a concurrently available fixed-price commodity. Purchasing tasks generated measures of demand elasticity, that is, sensitivity of consumption to prices. In single-commodity tasks, consumption of tobacco cigarette puffs (elasticity of demand: α = 0.0075; 95% confidence interval [0.0066, 0.0085], R² = 0.72) and of marijuana puffs (α = .0044; 95% confidence interval [0.0038, 0.0049], R² = 0.71) declined significantly with increases in price per puff. In cross-commodity tasks when both tobacco cigarette puffs and marijuana puffs were available, demand for 1 commodity was independent of price increases in the other commodity (ps > .05). Results revealed that, in this small sample, marijuana and tobacco cigarettes did not substitute for each other and did not complement each other; instead, they were independent of each other. These preliminary results can inform future studies assessing the economic relationship between tobacco and marijuana in the quickly changing policy climate in the United States. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  20. Impact of e-liquid flavors on e-cigarette vaping behavior.

    PubMed

    St Helen, Gideon; Shahid, Marian; Chu, Sherman; Benowitz, Neal L

    2018-05-31

    The primary objective of this pilot study was to describe the impact of e-cigarette liquid flavors on experienced e-cigarette users' vaping behavior. 11 males and 3 females participated in a 3-day inpatient crossover study using e-cigarettes with strawberry, tobacco, and their usual brand e-liquid. Nicotine levels were nominally 18 mg/mL in the strawberry and tobacco e-liquids and ranged between 3-18 mg/mL in the usual brands. On each day, participants had access to the study e-cigarette (KangerTech mini ProTank 3, 1.5 Ohms, 3.7 V) and the assigned e-liquid during a 90-minute videotaped ad libitum session. Average puff duration was significantly longer when using the strawberry e-liquid (3.2 ± 1.3 s, mean ± SD) compared to the tobacco e-liquid (2.8 ± 1.1 s) but the average number of puffs was not significantly different (strawberry, 73 ± 35; tobacco, 69 ± 46). Compared to the strawberry- and tobacco-flavored e-liquids, average puff duration was significantly longer (4.3 ± 1.6 s) and the average number of puffs was significantly higher (106 ± 67 puffs) when participants used their usual brand of e-liquid. Participants generally puffed more frequently in small groups of puffs (1-5 puffs) with the strawberry compared to the tobacco e-liquid and more frequently in larger groups (>10 puffs) with their usual brand. The strength of the relationship between vaping topography and nicotine intake and exposure were not consistent across e-liquids. Vaping behavior changes across e-liquids and influences nicotine intake. Research is needed to understand the mechanisms that underlie these behavioral changes, including e-liquid pH and related sensory effects, subjective liking, and nicotine effects. Copyright © 2018. Published by Elsevier B.V.

  1. E-cigarette puffing patterns associated with high and low nicotine e-liquid strength: effects on toxicant and carcinogen exposure.

    PubMed

    Cox, Sharon; Kośmider, Leon; McRobbie, Hayden; Goniewicz, Maciej; Kimber, Catherine; Doig, Mira; Dawkins, Lynne

    2016-09-20

    Contrary to intuition, use of lower strength nicotine e-liquids might not offer reduced health risk if compensatory puffing behaviour occurs. Compensatory puffing (e.g. more frequent, longer puffs) or user behaviour (increasing the wattage) can lead to higher temperatures at which glycerine and propylene glycol (solvents used in e-liquids) undergo decomposition to carbonyl compounds, including the carcinogens formaldehyde and acetaldehyde. This study aims to document puffing patterns and user behaviour associated with using high and low strength nicotine e-liquid and associated toxicant/carcinogen exposure in experienced e-cigarette users (known as vapers herein). A counterbalanced repeated measures design. Non-tobacco smoking vapers; have used an e-cigarette for ≥3 months; currently using nicotine strength e-liquid ≥12mg/mL and a second or third generation device. This study will measure puffing patterns in vapers whilst they use high and low strength nicotine e-liquid under fixed and user-defined settings, each for a week. The 4 counterbalanced conditions are: i) low strength (6mg/mL), fixed settings; ii) low strength user-defined settings; iii) high strength (18mg/mL) fixed settings; iv) high strength user-defined settings. Biomarkers of exposure to toxicants and carcinogens will be measured in urine. In the second phase of this study, toxicant yields will be measured in aerosol generated using a smoking machine operated to replicate the puffing behaviours of each participant. i) Puffing patterns (mean puff number, puff duration, inter-puff interval and mL of liquid consumed) and user behaviour (changes to device settings: voltage and air-flow) associated with using high and low strength nicotine e-liquid. ii) Toxicant/carcinogen exposure associated with the puffing patterns/device settings used by our participants. i) Subjective effects. ii) comparisons with toxicant exposure from tobacco smoke (using documented evidence) and with recommended safety limits. Twenty participants. The findings will have important implications for public health messaging regarding the relative risks and subjective effects associated with using high and low strength nicotine e-liquid, and for policy makers regarding regulations on nicotine concentrations in e-liquids.

  2. Debris-free soft x-ray source with gas-puff target

    NASA Astrophysics Data System (ADS)

    Ni, Qiliang; Chen, Bo; Gong, Yan; Cao, Jianlin; Lin, Jingquan; Lee, Hongyan

    2001-12-01

    We have been developing a debris-free laser plasma light source with a gas-puff target system whose nozzle is driven by a piezoelectric crystal membrane. The gas-puff target system can utilize gases such as CO2, O2 or some gas mixture according to different experiments. Therefore, in comparison with soft X-ray source using a metal target, after continuously several-hour laser interaction with gas from the gas-puff target system, no evidences show that the light source can produce debris. The debris-free soft X-ray source is prepared for soft X-ray projection lithography research at State Key Laboratory of Applied Optics. Strong emission from CO2, O2 and Kr plasma is observed.

  3. A Genetic RNAi Screen for IP3/Ca2+ Coupled GPCRs in Drosophila Identifies the PdfR as a Regulator of Insect Flight

    PubMed Central

    Agrawal, Tarjani; Sadaf, Sufia; Hasan, Gaiti

    2013-01-01

    Insect flight is regulated by various sensory inputs and neuromodulatory circuits which function in synchrony to control and fine-tune the final behavioral outcome. The cellular and molecular bases of flight neuromodulatory circuits are not well defined. In Drosophila melanogaster, it is known that neuronal IP3 receptor mediated Ca2+ signaling and store-operated Ca2+ entry (SOCE) are required for air-puff stimulated adult flight. However, G-protein coupled receptors (GPCRs) that activate intracellular Ca2+ signaling in the context of flight are unknown in Drosophila. We performed a genetic RNAi screen to identify GPCRs that regulate flight by activating the IP3 receptor. Among the 108 GPCRs screened, we discovered 5 IP3/Ca2+ linked GPCRs that are necessary for maintenance of air-puff stimulated flight. Analysis of their temporal requirement established that while some GPCRs are required only during flight circuit development, others are required both in pupal development as well as during adult flight. Interestingly, our study identified the Pigment Dispersing Factor Receptor (PdfR) as a regulator of flight circuit development and as a modulator of acute flight. From the analysis of PdfR expressing neurons relevant for flight and its well-defined roles in other behavioral paradigms, we propose that PdfR signaling functions systemically to integrate multiple sensory inputs and modulate downstream motor behavior. PMID:24098151

  4. Quantitative assessment of responses of the eyeball based on data from the Corvis tonometer.

    PubMed

    Koprowski, Robert; Wilczyński, Sławomir; Nowinska, Anna; Lyssek-Boron, Anita; Teper, Sławomir; Wylegala, Edward; Wróbel, Zygmunt

    2015-03-01

    The "air-puff" tonometers, include the Corvis, are a type of device for measuring intraocular pressure and biomechanics parameters. The paper attempts to analyse this response and its relationship with other parameters measured in the Corvis tonometer. A number of 13,400 2D images were acquired from the Corvis device and analysed (32 healthy and 16 ill people). A new method has been proposed for the analysis of responses of the eyeball based on morphological transformations and contextual operations. The proposed algorithm enables to determine responses of the eyeball to an air puff coming from the Corvis tonometer. Additionally, responses of the eyeball have been linked to some selected features of corneal deformation. The results include, among others: (1) distinguishability between the left and right eye with an error of 7%; (2) the correlation between the area under the curve in corneal deformation and the response of the eyeball -0.26; (3) the correlation between the highest concavity time and the maximum deformation amplitude of 0.4. All these features are obtained fully automatically and repetitively at a time of 3.8s per patient (Core i7 10GB RAM). It is possible to measure additional parameters of the eye deformation which are not available in the original software of the Corvis tonometer. The use of the proposed methods of image analysis and processing provides results directly from the eye response measurement when measuring intraocular pressure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Considerations for SphygmoCor radial artery pulse wave analysis: side selection and peripheral arterial blood pressure calibration.

    PubMed

    Martin, Jeffrey S; Borges, Alexandra R; Christy, John B; Beck, Darren T

    2015-10-01

    Methods employed for pulse wave analysis (PWA) and peripheral blood pressure (PBP) calibration vary. The purpose of this study was to evaluate the agreement of SphygmoCor PWA parameters derived from radial artery tonometry when considering (1) timing (before vs. after tonometry) and side selection (ipsilateral vs. contralateral limb) for PBP calibration and (2) side selection for tonometry (left vs. right arm). In 34 subjects (aged 21.9 ± 2.3 years), bilateral radial artery tonometry was performed simultaneously on three instances. PBP assessment via oscillometric sphygmomanometry in the left arm only and both arms simultaneously occurred following the first and second instances of tonometry, respectively. Significant within arm differences in PWA parameters derived before and after PBP measurement were observed in the right arm only (for example, aortic systolic blood pressure, Δ=0.38 ± 0.64 mm Hg). Simultaneously captured bilateral PWA variables demonstrated significant between arm differences in 88% (14/16) and 56% (9/16) of outcome variables when calibrated to within arm and equivalent PBP, respectively. Moreover, the right arm consistently demonstrated lower values for clinical PWA variables (for example, augmentation index, bias=-2.79%). However, 26% (n=9) of participants presented with clinically significant differences (>10 mm Hg) in bilateral PBP and their exclusion from analysis abolished most between arm differences observed. SphygmoCor PWA in the right radial artery results in greater variability independent of the timing of PBP measurement and magnitude of calibration pressures in young subjects. Moreover, bilateral PBP measurement is imperative to identify subjects in whom a significant difference in bilateral PWA outcomes may exist.

  6. [New trends in tonometry].

    PubMed

    Draeger, J A; Schwenteck, T; Ruokonen, P C

    2006-10-01

    Though the knowledge about the risk of elevated intraocular pressure for pathogenesis for development and progress of glaucoma is more than 400 years old. It took another 300 years before by means of tonometry this elevation could be quantified. After discussion of the key words it is our aim to demonstrate the latest trends in tonometry, specifically by use of modern electronics for instrument design. Goldmann was the founder of the "applanation tonometry", measuring the corelation of applanated area and applied force. Here, the next step was the development of instruments, measuring independent of position or gravity to allow application also at the lying patient. Electronic area detection was the next step to avoid examinor's error. Also important was the introduction of automatic UV-desinfection to avoid contamination of the other eye or other patients. Other tonometers control the force applied by an inductive method, which also allows application independent of position. Airpuff-tonometry uses completely different measuring principles - the resulting change of corneal curvature indicates the intraocular pressure. The impedance principle is applied even through the closed eye lid. The shock waves resulting shall be measured. Direct application of a surface sensor incorporated into a concave surface contact body shall allow direct measurement of intraocular pressure independent of corneal thickness, curvature, astigmatism. This method has been tried for more than 20 years. Also exposition of the eye to count waves of different frequency was an early attempt. Here also change of reflectivity is used to calculate intraocular pressure. Even after use of modern electronic technology the precision of many of these new devices does not lead to better results. This specifically is shown by modern calibration methods.

  7. The impact of flavoring on the rewarding and reinforcing value of e-cigarettes with nicotine among young adult smokers.

    PubMed

    Audrain-McGovern, Janet; Strasser, Andrew A; Wileyto, E Paul

    2016-09-01

    Flavored e-cigarette use has risen rapidly, especially among young adults who also smoke cigarettes. We sought to determine whether flavoring enhances the subjective rewarding value, relative reinforcing value, and absolute reinforcing value of an e-cigarette with nicotine compared to an unflavored e-cigarette with nicotine. Using a within-subjects design, young adult smokers (n=32) participated in three human laboratory sessions. Session 1 evaluated the rewarding value of flavoring by having participants rate unflavored and flavored e-cigarettes with nicotine. Session 2 assessed the relative reinforcing value of a flavored vs unflavored e-cigarette via a choice task that evaluated the willingness to "work" to hit targets on a computer screen to earn flavored or unflavored e-cigarette puffs. Session 3 measured the absolute reinforcing value of flavored versus unflavored e-cigarettes via a 90-min ad-libitum vaping session where puffs from each e-cigarette were counted. Subjective reward value was higher for the flavored versus the unflavored e-cigarette (β=0.83, CI 0.35-1.32, p=0.001). Participants worked harder for flavored e-cigarette puffs versus unflavored e-cigarette puffs (breakpoint=5.7; 597 responses versus 127 responses; β=460.733, CI 246.58-674.88, p<0.0001). Participants took twice as many flavored puffs than unflavored e-cigarette puffs (40 vs 23 puffs; IRR=2.028, CI 1.183-3.475, p=0.01). Flavoring enhances the rewarding and reinforcing value of e-cigarettes with nicotine, and thus their abuse liability in young adult smokers. Further research is necessary to determine whether the use of flavoring in e-cigarettes impacts cigarette smoking behavior among young adults. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. The impact of flavoring on the rewarding and reinforcing value of e-cigarettes with nicotine among young adult smokers

    PubMed Central

    Audrain-McGovern, Janet; Strasser, Andrew A.; Wileyto, E. Paul

    2016-01-01

    Objective Flavored e-cigarette use has risen rapidly, especially among young adults who also smoke cigarettes. We sought to determine whether flavoring enhances the subjective rewarding value, relative reinforcing value, and absolute reinforcing value of an e-cigarette with nicotine compared to an unflavored e-cigarette with nicotine. Methods Using a within-subjects design, young adult smokers (n=32) participated in three human laboratory sessions. Session 1 evaluated the rewarding value of flavoring by having participants rate unflavored and flavored e-cigarettes with nicotine. Session 2 assessed the relative reinforcing value of a flavored vs unflavored e-cigarette via a choice task that evaluated the willingness to “work” to hit targets on a computer screen to earn flavored or unflavored e-cigarette puffs. Session 3 measured the absolute reinforcing value of flavored versus unflavored e-cigarettes via a 90-minute ad-libitum vaping session where puffs from each e-cigarette were counted. Results Subjective reward value was higher for the flavored versus the unflavored e-cigarette (β=.83, CI 0.35 to 1.32, p=0.001). Participants worked harder for flavored e-cigarette puffs versus unflavored e-cigarette puffs (breakpoint = 5.7; 597 responses versus 127 responses; β=460.733, CI 246.58 to 674.88, p <0.0001). Participants took twice as many flavored puffs than unflavored e-cigarette puffs (40 vs 23 puffs; IRR=2.028, CI 1.183 to 3.475, p=0.01). Conclusions Flavoring enhances the rewarding and reinforcing value of e-cigarettes with nicotine, and thus their abuse liability in young adult smokers. Further research is necessary to determine whether the use of flavoring in e-cigarettes impacts cigarette smoking behavior among young adults. PMID:27426010

  9. Buffer regulation of calcium puff sequences.

    PubMed

    Fraiman, Daniel; Dawson, Silvina Ponce

    2014-02-01

    Puffs are localized Ca(2 +) signals that arise in oocytes in response to inositol 1,4,5-trisphosphate (IP3). They are the result of the liberation of Ca(2 +) from the endoplasmic reticulum through the coordinated opening of IP3 receptor/channels clustered at a functional release site. The presence of buffers that trap Ca(2 +) provides a mechanism that enriches the spatio-temporal dynamics of cytosolic calcium. The expression of different types of buffers along the cell's life provides a tool with which Ca(2 +) signals and their responses can be modulated. In this paper we extend the stochastic model of a cluster of IP3R-Ca(2 +) channels introduced previously to elucidate the effect of buffers on sequences of puffs at the same release site. We obtain analytically the probability laws of the interpuff time and of the number of channels that participate of the puffs. Furthermore, we show that under typical experimental conditions the effect of buffers can be accounted for in terms of a simple inhibiting function. Hence, by exploring different inhibiting functions we are able to study the effect of a variety of buffers on the puff size and interpuff time distributions. We find the somewhat counter-intuitive result that the addition of a fast Ca(2 +) buffer can increase the average number of channels that participate of a puff.

  10. Influence of Smoking Puff Parameters and Tobacco Varieties on Free Radicals Yields in Cigarette Mainstream Smoke.

    PubMed

    Goel, Reema; Bitzer, Zachary T; Reilly, Samantha M; Foulds, Jonathan; Muscat, Joshua; Elias, Ryan J; Richie, John P

    2018-05-07

    Cigarette smoke is a major exogenous source of free radicals, and the resulting oxidative stress is one of the major causes of smoking-caused diseases. Yet, many of the factors that impact free radical delivery from cigarettes remain unclear. In this study, we machine-smoked cigarettes and measured the levels of gas- and particulate-phase radicals by electron paramagnetic resonance (EPR) spectroscopy using standardized smoking regimens (International Organization of Standardization (ISO) and Canadian Intense (CI)), puffing parameters, and tobacco blends. Radical delivery per cigarette was significantly greater in both gas (4-fold) and particulate (6-fold) phases when cigarettes were smoked under the CI protocol compared to the ISO protocol. Total puff volume per cigarette was the major factor with radical production being proportional to total volume, regardless of whether volume differences were achieved by changes in individual puff volume or puff frequency. Changing puff shape (bell vs sharp vs square) or puff duration (1-5 s), without changing volume, had no effect on radical yields. Tobacco variety did have a significant impact on free radical production, with gas-phase radicals highest in reconstituted > burley > oriental > bright tobacco and particulate-phase radicals highest in burley > bright > oriental > reconstituted tobacco. Our findings show that modifiable cigarette design features and measurable user smoking behaviors are key factors determining free radical exposure in smokers.

  11. Nicotine Delivery and Vaping Behavior During ad Libitum E-cigarette Access

    PubMed Central

    St.Helen, Gideon; Ross, Kathryn C.; Dempsey, Delia A.; Havel, Christopher M.; Jacob, Peyton; Benowitz, Neal L.

    2017-01-01

    Objective To characterize vaping behavior and nicotine intake during ad libitum e-cigarette access. Methods Thirteen adult e-cigarette users had 90 minutes of videotaped ad libitum access to their usual e-cigarette. Plasma nicotine was measured before and every 15 minutes after the first puff; subjective effects were measured before and after the session. Results Average puff duration and interpuff interval were 3.5±1.4 seconds (±SD) and 118±141 seconds, respectively. 12% of puffs were unclustered puffs while 43%, 28%, and 17% were clustered in groups of 2–5, 6–10, and >10 puffs, respectively. On average, 4.0±3.3 mg of nicotine was inhaled; the maximum plasma nicotine concentration (Cmax) was 12.8±8.5 ng/mL. Among the 8 tank users, number of puffs was positively correlated with amount of nicotine inhaled, Cmax, and area under the plasma nicotine concentration-time curve (AUC0→90min) while interpuff interval was negatively correlated with Cmax and AUC0→90. Conclusion Vaping patterns differ from cigarette smoking. Plasma nicotine levels were consistent with intermittent dosing of nicotine from e-cigarettes compared to the more bolus dosing from cigarettes. Differences in delivery patterns and peak levels of nicotine achieved could influence the addictiveness of e-cigarettes compared to conventional cigarettes. PMID:28393086

  12. Buffer regulation of calcium puff sequences

    NASA Astrophysics Data System (ADS)

    Fraiman, Daniel; Ponce Dawson, Silvina

    2014-02-01

    Puffs are localized Ca2 + signals that arise in oocytes in response to inositol 1,4,5-trisphosphate (IP3). They are the result of the liberation of Ca2 + from the endoplasmic reticulum through the coordinated opening of IP3 receptor/channels clustered at a functional release site. The presence of buffers that trap Ca2 + provides a mechanism that enriches the spatio-temporal dynamics of cytosolic calcium. The expression of different types of buffers along the cell's life provides a tool with which Ca2 + signals and their responses can be modulated. In this paper we extend the stochastic model of a cluster of IP3R-Ca2 + channels introduced previously to elucidate the effect of buffers on sequences of puffs at the same release site. We obtain analytically the probability laws of the interpuff time and of the number of channels that participate of the puffs. Furthermore, we show that under typical experimental conditions the effect of buffers can be accounted for in terms of a simple inhibiting function. Hence, by exploring different inhibiting functions we are able to study the effect of a variety of buffers on the puff size and interpuff time distributions. We find the somewhat counter-intuitive result that the addition of a fast Ca2 + buffer can increase the average number of channels that participate of a puff.

  13. Impact of low-trans fat compositions on the quality of conventional and fat-reduced puff pastry.

    PubMed

    Silow, Christoph; Zannini, Emanuele; Arendt, Elke K

    2016-04-01

    Four vegetable fat blends (FBs) with low trans-fatty acid (TFA ≤ 0.6 %) content with various ratios of palm stearin (PS) and rapeseed oil (RO) were characterised and examined for their application in puff pastry production. The amount of PS decreased from FB1 to FB4 and simultaneously the RO content increased. A range of analytical methods were used to characterise the FBs, including solid fat content (SFC), differential scanning calorimetry (DSC), cone penetrometry and rheological measurements. The internal and external structural quality parameters of baked puff pastry were investigated using texture analyser equipped with an Extended Craft Knife (ECK), VolScan and C-Cell image system. Puff pastry containing FB1 and FB2 achieved excellent baking results for full fat and fat-reduced puff pastry; hence these FBs contained adequate shortening properties. A fat reduction by 40 % using FB2 and a reduction of saturated fatty acids (SAFA) by 49 %, compared to the control, did not lead to adverse effects in lift and specific volume. The higher amount of RO and the lower SAFA content compared to FB1 coupled with the satisfying baking results makes FB2 the fat of choice in this study. FB3 and FB4 were found to be unsuitable for puff pastry production because of their melting behaviour.

  14. A New Variety of CMEs: Streamer Puffs from Compact Ejective Flares

    NASA Technical Reports Server (NTRS)

    Sterling, Alphonse C.; Bemporad, A.; Moore, R. L.; Poletto, G.

    2005-01-01

    We present SOHO EIT, UVCS and LASCO observations of recurrent (6 --- 8 events per day) narrow (angular widths of about 3 --- 10 degrees) Coronal Mass Ejections (CMEs) which occurred over 2002 November 26--29. The active region where the ejections originate is near the base of a coronal streamer that appears to be unperturbed by the events and keeps stable in time; hence we interpret the observed events as a new class of recursive narrow CMEs that we call "streamer puffs." EIT 304 angstrom (He II) images indicate that the puffs result from compact ejective flares embedded in the streamer, with the ejections from the flares having velocities 100 --- 200 kilometers per second. Most ejections are closely correlated with coronal "jets" seen at 1.7 solar radii in the UVCS data, and a subset of these ejections and jets correspond to streamer puffs observed in LASCO coronagraph images. There are, however, more compact flares and jets than streamer puffs during the observation period, indicating that only a subset of the flare-associated ejections are energetic enough to escape into the heliosphere.

  15. Radial and Azimuthal Velocity Profiles in Gas-Puff Z-Pinches

    NASA Astrophysics Data System (ADS)

    Rocco, Sophia; Engelbrecht, Joseph; Banasek, Jacob; de Grouchy, Philip; Qi, Niansheng; Hammer, David

    2016-10-01

    The dynamics of neon, argon, and krypton (either singly or in combination) gas puff z-pinch plasmas are studied on Cornell's 1MA, 100-200ns rise-time COBRA pulsed power generator. The triple-nozzle gas puff valve, consisting of two annular gas puffs and a central jet, allows radial tailoring of the gas puff mass-density profile and the use of 1, 2 or 3 different gases at different pressures. Interferometry supplies information on sheath thickness and electron density, variously filtered PCDs and silicon diodes measure hard and soft x-ray production, and multi frame visible and extreme UV imaging systems allow tracking of the morphology of the plasma. A 527nm, 10J Thomson scattering diagnostic system is used to determine radial and azimuthal velocities. Implosion velocities of 170km/s (Kr) and 300km/s (Ne/Ar) are observed. We are investigating the correlations between instability growth, plasma density profile, velocity partitioning as a function of radius, and radiation production. Research supported by the NNSA Stewardship Sciences Academic Programs under DOE Cooperative Agreement No. DE-NA0001836.

  16. Intra-puff CO and CO 2 measurements of cigarettes with iron oxide cigarette paper using quantum cascade laser spectroscopy

    NASA Astrophysics Data System (ADS)

    Crawford, Danielle R.; Parrish, Milton E.; Gee, Diane L.; Harward, Charles N.

    2007-05-01

    The objective of this research was to apply Fourier transform infrared spectroscopy (FTIR) and tunable infrared laser differential absorption spectroscopy (TILDAS) for measuring selected gaseous constituents in mainstream (MS) and sidestream (SS) smoke for experimental cigarettes designed to reduce MS CO using iron oxide cigarette papers. These two complimentary analytical techniques are well suited for providing per puff smoke deliveries and intra-puff evolution profiles in cigarette smoke respectively. The quad quantum cascade (QC) laser high resolution infrared spectroscopy system has the necessary temporal and spectral resolution and whole smoke analysis capabilities to provide detailed information for CO and CO 2 as they are being formed in both MS and SS smoke. The QC laser system has an optimal data rate of 20 Hz and a unique puffing system, with a square wave shaped puff, that allows whole smoke to enter an 18 m, 0.3 L multi-pass gas cell in real time (0.1 s cell response time) requiring no syringe or Cambridge filter pad. Another similar multi-pass gas cell with a 36 m pathlength simultaneously monitors the sidestream cigarette smoke. The smoke from experimental cigarettes manufactured with two types of iron oxide papers were compared to the smoke from cigarettes manufactured similarly without iron oxide in the paper using both instrument systems. The delivery per puff determined by the QC laser method agreed with FTIR results. MS CO intra-puff evolution profiles for iron oxide prototype cigarettes demonstrated CO reduction when compared to cigarettes without iron oxide paper. Additionally, both CO and CO 2 intra-puff evolution profiles of the cigarettes with iron oxide paper showed a significant reduction at the initial portion of the 2 s puff not observed in the non-iron oxide prototype cigarettes. This effect also was observed for ammonia and ethylene, suggesting that physical parameters such as paper porosity and burn rate are important. The SS CO and CO 2 deliveries for the experimental cigarettes evaluated remained unaffected. The iron oxide paper technology remains under development and continues to be evaluated.

  17. Intra-puff CO and CO2 measurements of cigarettes with iron oxide cigarette paper using quantum cascade laser spectroscopy.

    PubMed

    Crawford, Danielle R; Parrish, Milton E; Gee, Diane L; Harward, Charles N

    2007-05-01

    The objective of this research was to apply Fourier transform infrared spectroscopy (FTIR) and tunable infrared laser differential absorption spectroscopy (TILDAS) for measuring selected gaseous constituents in mainstream (MS) and sidestream (SS) smoke for experimental cigarettes designed to reduce MS CO using iron oxide cigarette papers. These two complimentary analytical techniques are well suited for providing per puff smoke deliveries and intra-puff evolution profiles in cigarette smoke respectively. The quad quantum cascade (QC) laser high resolution infrared spectroscopy system has the necessary temporal and spectral resolution and whole smoke analysis capabilities to provide detailed information for CO and CO(2) as they are being formed in both MS and SS smoke. The QC laser system has an optimal data rate of 20 Hz and a unique puffing system, with a square wave shaped puff, that allows whole smoke to enter an 18 m, 0.3 L multi-pass gas cell in real time (0.1s cell response time) requiring no syringe or Cambridge filter pad. Another similar multi-pass gas cell with a 36 m pathlength simultaneously monitors the sidestream cigarette smoke. The smoke from experimental cigarettes manufactured with two types of iron oxide papers were compared to the smoke from cigarettes manufactured similarly without iron oxide in the paper using both instrument systems. The delivery per puff determined by the QC laser method agreed with FTIR results. MS CO intra-puff evolution profiles for iron oxide prototype cigarettes demonstrated CO reduction when compared to cigarettes without iron oxide paper. Additionally, both CO and CO(2) intra-puff evolution profiles of the cigarettes with iron oxide paper showed a significant reduction at the initial portion of the 2 s puff not observed in the non-iron oxide prototype cigarettes. This effect also was observed for ammonia and ethylene, suggesting that physical parameters such as paper porosity and burn rate are important. The SS CO and CO(2) deliveries for the experimental cigarettes evaluated remained unaffected. The iron oxide paper technology remains under development and continues to be evaluated.

  18. Intra-Ocular Pressure Measurement in a Patient with a Thin, Thick or Abnormal Cornea.

    PubMed

    Clement, Colin I; Parker, Douglas G A; Goldberg, Ivan

    2016-01-01

    Accurate measurement of intra-ocular pressure is a fundamental component of the ocular examination. The most common method of measuring IOP is by Goldmann applanation tonometry, the accuracy of which is influenced by the thickness and biomechanical properties of the cornea. Algorithms devised to correct for corneal thickness to estimate IOP oversimplify the effects of corneal biomechanics. The viscous and elastic properties of the cornea influence IOP measurements in unpredictable ways, a finding borne out in studies of patients with inherently abnormal and surgically altered corneal biomechanics. Dynamic contour tonometry, rebound tonometry and the ocular response analyzer provide useful alternatives to GAT in patients with abnormal corneas, such as those who have undergone laser vision correction or keratoplasty. This article reviews the various methods of intra-ocular pressure measurement available to the clinician and the ways in which their utility is influenced by variations in corneal thickness and biomechanics.

  19. Smoking Topography in Korean American and White Men: Preliminary Findings

    PubMed Central

    Chung, Sangkeun; Kim, Sun S; Kini, Nisha; Fang, Hua J; Kalman, David; Ziedonis, Douglas M.

    2013-01-01

    Introduction This is the first study of Korean Americans’ smoking behavior using a topography device. Korean American men smoke at higher rates than the general U.S. population. Methods Korean American and White men were compared based on standard tobacco assessment and smoking topography measures. They smoked their preferred brand of cigarettes ad libitum with a portable smoking topography device for 24 hours. Results Compared to White men (N = 26), Korean American men (N = 27) were more likely to smoke low nicotine-yield cigarettes (p < 0.001) and have lower Fagerstrom nicotine dependence scores (p = 0.04). Koreans smoked fewer cigarettes with the device (p = 0.01) than Whites. Controlling for the number of cigarettes smoked, Koreans smoked with higher average puff flows (p = 0.05), greater peak puff flows (p = 0.02), and shorter interpuff intervals (p < 0.001) than Whites. Puff counts, puff volumes, and puff durations did not differ between the two groups. Conclusions This study offers preliminary insight into unique smoking patterns among Korean American men who are likely to smoke low nicotine-yield cigarettes. We found that Korean American men compensated their lower number and low nicotine-yield cigarettes by smoking more frequently with greater puff flows than White men, which may suggest exposures to similar amounts of nicotine and harmful tobacco toxins by both groups. Clinicians will need to consider in identifying and treating smokers in a mutually aggressive manner, irrespective of cigarette type and number of cigarette smoked per day. PMID:24068611

  20. Marijuana smoking: effects of varying puff volume and breathhold duration.

    PubMed

    Azorlosa, J L; Greenwald, M K; Stitzer, M L

    1995-02-01

    Two studies were conducted to quantify biological and behavioral effects resulting from exposure to controlled doses of marijuana smoke. In one study, puff volume (30, 60 and 90 ml) and in a second study, breathhold duration (0, 10 and 20 sec) were systematically varied while holding constant other smoking topography parameters (number of puffs = 10, interpuff interval = 60 sec and inhalation volume = 25% of vital capacity). Each study also varied levels of delta 9-tetrahydro-cannabinol marijuana cigarette content (1.75% and 3.55%). Regular marijuana users served as subjects (n = 7 in each experiment). Subjects smoked 10 puffs in each of six sessions; a seventh, nonsmoking session (all measures recorded at the same times as in active smoking sessions) served as a control. Variations in puff volume produced significant dose-related changes in postsmoking plasma delta 9-tetrahydro-cannabinol levels, carbon monoxide boost and subjective effects (e.g., "high"). In contrast, breathholding for 10 or 20 sec versus 0 sec increased plasma delta 9-tetrahydro-cannabinol levels but not CO boost or subjective effects. Task performance measures were not reliably influenced by marijuana smoke exposure within the dosing ranges examined. These findings confirm the utility of the controlled smoking technology, support the notion that cumulative puff volume systematically influences biological exposure and subjective effects, but cast doubt on the common belief that prolonged breathholding of marijuana smoke enhances classical subjective effects associated with its reinforcing value in humans.

  1. Plasma-puff initiation of high Coulomb transfer switches

    NASA Technical Reports Server (NTRS)

    Han, Kwang S.; Venable, Demetrius D.; Lee, Ja H.; Choi, Eun H.; Kim, Y. K.; Kim, J. H.; Nguyen, D. X.

    1993-01-01

    The plasma-puff triggering mechanism based on a hypocycloidal pinch geometry was investigated to determine the optimal operating conditions for an azimuthally uniform surface flashover which initiates plasma-puff under wide ranges of fill gas pressures of Ar, He and N2. The optimal fill gas pressures for the azimuthally uniform plasma-puff were about 120 mTorr less than P(sub opt) less than 450 Torr for He and N2. For Argon 20 mTorr is less than P(sub opt) is less than 5 Torr. The inverse pinch switch was triggered with the plasma-puff and the switching capability under various electrical parameters and working gas pressures of Ar, He and N2 was determined. It was also shown that the azimuthally uniform switching discharges were dependent on the type of fill gas and its fill pressure. A new concept of plasma-focus driven plasma-puff was also discussed in comparison with hypocycloidal pinch plasma-puff triggering. The main discharge of the inverse pinch switch with the plasma-focus driven plasma-puff trigger is found to be more azimuthally uniform than that with the hypocycloidal pinch plasma-puff trigger in a gas pressure region between 80 mTorr and 1 Torr. In order to assess the effects of plasma current density on material erosion of electrodes, emissions from both an inverse-pinch plasma switch (INPIStron) and from a spark gap switch under test were studied with an optical multichannel analyzer (OMA). The color temperature of the argon plasma was approximately 4,000 K which corresponded with the peak continuum emission near 750 nm. There are the strong line emissions of argon in the 650 - 800 nm range and a lack of line emissions of copper and other solid material used in the switch. This indicates that the plasma current density during closing is low and the hot spot or hot filament in the switch is negligible. This result also indicates considerable reduction of line emission with the INPIStron switch over that of a spark-gap switch. However, a strong carbon line emission exists due to vaporization of the plastic insulator used. In order to reduce the vaporization of the insulator, the plexiglass insulating material of INPIStron was replaced with Z-9 material. A comparative study of the INPIStron and a spark gap also reveals that the INPIStron, with a low impedance of Z = 9 ohms, can transfer a high voltage pulse with a superior pulse-shape fidelity over that of a spark gap with Z = 100 ohms.

  2. Plasma-puff initiation of high Coulomb transfer switches

    NASA Technical Reports Server (NTRS)

    Venable, D. D.; Han, K. S.

    1993-01-01

    The plasma-puff triggering mechanism based on a hypocycloidal pinch geometry was investigated to determine the optimal operating conditions for an azimuthally uniform surface flashover which initiates plasma-puff under wide ranges of fill gas pressures of Ar, He and N2. The optimal fill gas pressures for the azimuthally uniform plasma-puff were about 120 mTorr less than P(opt) less than 450 Torr for He and N2. For Argon 120 mTorr less than P(opt) less than 5 Torr for argon. The inverse pinch switch was triggered with the plasma-puff and the switching capability under various electrical parameters and working gas pressures of Ar, He and N2 was determined. It was also shown that the azimuthally uniform switching discharges were dependent on the type of fill gas and its fill pressure. A new concept of plasma-focus driven plasma-puff was also discussed in comparison with hypocycloidal pinch plasma-puff triggering. The main discharge of the inverse pinch switch with the plasma-focus driven plasma-puff trigger is found to be more azimuthally uniform than that with the hypocycloidal pinch plasma-puff trigger in a gas pressure region between 80 mTorr and 1 Torr. In order to assess the effects of plasma current density on material erosion of electrodes, emissions from both an inverse-pinch plasma switch (INPIStron) and from a spark gap switch under test were studied with an optical multichannel analyzer (OMA). The color temperature of the argon plasma was approximately 4,000 K which corresponded with the peak continuum emission near 750 nm. There are the strong line emissions of argon in the 650 - 800 nm range and a lack of line emissions of copper and other solid material used in the switch. This indicates that the plasma current density during closing is low and the hot spot or hot filament in the switch is negligible. This result also indicates considerable reduction of line emission with the INPIStron switch over that of a spark-gap switch. However, a strong carbon line emission exists due to vaporization of the plastic insulator used. In order to reduce the vaporization of the insulator, the plexiglass insulating material of INPIStron was replaced with Z-9 material. A comparative study of the INPIStron and a spark gap also reveals that the INPIStron, with a low impedance of Z equals 9 ohms, can transfer a high voltage pulse with a superior pulse-shape fidelity over that of a spark gap with Z equals 100 ohms.

  3. Investigating the effect of adding an on-axis jet to Ar gas puff Z pinches on Z.

    DOE PAGES

    Harvey-Thompson, Adam James; Jennings, Christopher Ashley; Jones, Brent M.; ...

    2016-10-20

    Double-shell Ar gas puff implosions driven by 16.5±0.5 MA on the Z generator at Sandia National Laboratories are very effective emitters of Ar K-shell radiation (photon energy >3 keV), producing yields of 330 ± 9% kJ (B. Jones et al., Phys. Plasmas, 22, 020706, 2015). In addition, previous simulations and experiments have reported dramatic increases in K-shell yields when adding an on-axis jet to double shell gas puffs for some configurations.

  4. Measurement of acrolein and 1,3-butadiene in a single puff of cigarette smoke using lead-salt tunable diode laser infrared spectroscopy.

    PubMed

    Thweatt, W Dave; Harward, Charles N; Parrish, Milton E

    2007-05-01

    Acrolein and 1,3-butadiene in cigarette smoke generally are measured using two separate analytical methods, a carbonyl derivative HPLC method for acrolein and a volatile organic compound (VOC) GC/MS method for 1,3-butadiene. However, a single analytical method having improved sensitivity and real-time per puff measurement will offer more specific information for evaluating experimental carbon filtered cigarettes designed to reduce the smoke deliveries of these constituents. This paper describes an infrared technique using two lead-salt tunable diode lasers (TDLs) operating with liquid nitrogen cooling with emissions at 958.8 cm(-1) and 891.0 cm(-1) respectively for the simultaneous measurement of acrolein and 1,3-butadiene, respectively, in each puff of mainstream cigarette smoke in real time. The dual TDL system uses a 3.1l volume, 100 m astigmatic multiple pass absorption gas cell. Quantitation is based on a spectral fit that uses previously determined infrared molecular line parameters generated in our laboratory, including line positions, line strengths and nitrogen-broadened half-widths for these species. Since acrolein and ethylene absorption lines overlap and 1,3-butadiene, ethylene and propylene absorption lines overlap, the per puff deliveries of ethylene and propylene were determined since their overlapping absorption lines must be taken into account by the spectral fit. The acrolein and 1,3-butadiene total cigarette deliveries for the 1R5F Kentucky Reference cigarette were in agreement with the HPLC and GC/MS methods, respectively. The limit of detection (LOD) for 1,3-butadiene and acrolein was 4 ng/puff and 24 ng/puff, respectively, which is more than adequate to determine at which puff they break through the carbon filter. The retention and breakthrough behavior for the two primary smoke constituents depend on the cigarette design and characteristics of the carbon filter being evaluated.

  5. Measurement of acrolein and 1,3-butadiene in a single puff of cigarette smoke using lead-salt tunable diode laser infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Thweatt, W. Dave; Harward, Charles N., Sr.; Parrish, Milton E.

    2007-05-01

    Acrolein and 1,3-butadiene in cigarette smoke generally are measured using two separate analytical methods, a carbonyl derivative HPLC method for acrolein and a volatile organic compound (VOC) GC/MS method for 1,3-butadiene. However, a single analytical method having improved sensitivity and real-time per puff measurement will offer more specific information for evaluating experimental carbon filtered cigarettes designed to reduce the smoke deliveries of these constituents. This paper describes an infrared technique using two lead-salt tunable diode lasers (TDLs) operating with liquid nitrogen cooling with emissions at 958.8 cm -1 and 891.0 cm -1 respectively for the simultaneous measurement of acrolein and 1,3-butadiene, respectively, in each puff of mainstream cigarette smoke in real time. The dual TDL system uses a 3.1 l volume, 100 m astigmatic multiple pass absorption gas cell. Quantitation is based on a spectral fit that uses previously determined infrared molecular line parameters generated in our laboratory, including line positions, line strengths and nitrogen-broadened half-widths for these species. Since acrolein and ethylene absorption lines overlap and 1,3-butadiene, ethylene and propylene absorption lines overlap, the per puff deliveries of ethylene and propylene were determined since their overlapping absorption lines must be taken into account by the spectral fit. The acrolein and 1,3-butadiene total cigarette deliveries for the 1R5F Kentucky Reference cigarette were in agreement with the HPLC and GC/MS methods, respectively. The limit of detection (LOD) for 1,3-butadiene and acrolein was 4 ng/puff and 24 ng/puff, respectively, which is more than adequate to determine at which puff they break through the carbon filter. The retention and breakthrough behavior for the two primary smoke constituents depend on the cigarette design and characteristics of the carbon filter being evaluated.

  6. CHARACTERIZATION OF TRANSIENT PUFF EMISSIONS ...

    EPA Pesticide Factsheets

    Symposium Paper Transient puff emissions were characterized from burning carpet charges that were fed to a pilotscale rotary kiln combustor to assess the potential impact on emissions of using post-consumer carpet as an alternative fuel in cement kilns.

  7. Time-dependent buoyant puff model for explosive sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kansa, E.J.

    1997-01-01

    Several models exist to predict the time dependent behavior of bouyant puffs that result from explosions. This paper presents a new model that is derived from the strong conservative form of the conservation partial differential equations that are integrated over space to yield a coupled system of time dependent nonlinear ordinary differential equations. This model permits the cloud to evolve from an intial spherical shape not an ellipsoidal shape. It ignores the Boussinesq approximation, and treats the turbulence that is generated by the puff itself and the ambient atmospheric tubulence as separate mechanisms in determining the puff history. The puffmore » cloud rise history was found to depend no only on the mass and initial temperature of the explosion, but also upon the stability conditions of the ambient atmosphere. This model was calibrated by comparison with the Roller Coaster experiments.« less

  8. Electrical stimulation of the rostral medial prefrontal cortex in rabbits inhibits the expression of conditioned eyelid responses but not their acquisition

    PubMed Central

    Leal-Campanario, Rocío; Fairén, Alfonso; Delgado-García, José M.; Gruart, Agnès

    2007-01-01

    We have studied the role of rostral medial prefrontal cortex (mPFC) on reflexively evoked blinks and on classically conditioned eyelid responses in alert-behaving rabbits. The rostral mPFC was identified by its afferent projections from the medial half of the thalamic mediodorsal nuclear complex. Classical conditioning consisted of a delay paradigm using a 370-ms tone as the conditioned stimulus (CS) and a 100-ms air puff directed at the left cornea as the unconditioned stimulus (US). The CS coterminated with the US. Electrical train stimulation of the contralateral rostral mPFC produced a significant inhibition of air-puff-evoked blinks. The same train stimulation of the rostral mPFC presented during the CS–US interval for 10 successive conditioning sessions significantly reduced the generation of conditioned responses (CRs) as compared with values reached by control animals. Interestingly, the percentage of CRs almost reached control values when train stimulation of the rostral mPFC was removed from the fifth conditioning session on. The electrical stimulation of the rostral mPFC in well conditioned animals produced a significant decrease in the percentage of CRs. Moreover, the stimulation of the rostral mPFC was also able to modify the kinematics (latency, amplitude, and velocity) of evoked CRs. These results suggest that the rostral mPFC is a potent inhibitor of reflexively evoked and classically conditioned eyeblinks but that activation prevents only the expression of CRs, not their latent acquisition. Functional and behavioral implications of this inhibitory role of the rostral mPFC are discussed. PMID:17592148

  9. Effect of drug load and plate coating on the particle size distribution of a commercial albuterol metered dose inhaler (MDI) determined using the Andersen and Marple-Miller cascade impactors.

    PubMed

    Nasr, M M; Ross, D L; Miller, N C

    1997-10-01

    The purpose of this study is to investigate the effect of drug load, the coating of impactor stages, and the design of cascade impactors on albuterol MDIs particle size distribution measurements. The results of the investigation will be used to explain the "loading effect" recently reported. Particle size distribution parameters of a commercial albuterol MDI were measured using both Andersen (AI) and Marple-Miller (MMI) Cascade Impactors, where plates were either left uncoated or coated with silicone or glycerin. A previously validated HPLC-EC method was used for the assay of albuterol collected by the impactor and in single spray content determinations. Coating impactor collection plates had an impact on measured MMAD and GSD values for single puff measurements but very little or no effect for the multi puff measurements. Due to particle bounce, the percent of albuterol fine particles deposited in the filter and impactor finer stages (< 1.10 microns in AI and < 1.25 microns in MMI) in uncoated single puff experiments was much higher in comparison to either coated single puff or multi-puff (coated and uncoated) measurements. Evaluation of drug load and plate coating are necessary to determine whether observed particle size distributions are representative of the generated aerosol or are the result of particle bounce and reentrainment. In order to minimize particle bounce, especially for single puff determinations, it may be useful to apply a thin layer of a sticky coating agent to the surfaces of impactor plates.

  10. Forming Super-Puffs Beyond 1 AU

    NASA Astrophysics Data System (ADS)

    Lee, Eve J.; Chiang, Eugene

    2017-06-01

    Super-puffs are an uncommon class of short-period planets seemingly too voluminous for their small masses (4-10 Rearth, 2-6 Mearth). Super-puffs most easily acquire their thick atmospheres as dust-free, rapidly cooling worlds outside ˜1AU where nebular gas is colder, less dense, and therefore less opaque. These puffy planets probably migrated in to their current orbits; they are expected to form the outer links of mean-motion resonant chains, and to exhibit atmospheric characteristics consistent with formation at large distances. I will also discuss, in general, how densities of planets can be used to infer their formation locations.

  11. Short-Term Exposure to Air Pollution and Digital Vascular Function

    PubMed Central

    Ljungman, Petter L.; Wilker, Elissa H.; Rice, Mary B.; Schwartz, Joel; Gold, Diane R.; Koutrakis, Petros; Vita, Joseph A.; Mitchell, Gary F.; Vasan, Ramachandran S.; Benjamin, Emelia J.; Mittleman, Murray A.; Hamburg, Naomi M.

    2014-01-01

    We investigated associations between ambient air pollution and microvessel function measured by peripheral arterial tonometry between 2003 and 2008 in the Framingham Heart Study Offspring and Third Generation Cohorts. We measured particulate matter with aerodynamic diameter ≤2.5 µm (PM2.5), black carbon, sulfates, particle number, nitrogen oxides, and ozone by using fixed monitors, and we determined moving averages for 1–7 days preceding vascular testing. We examined associations between these exposures and hyperemic response to ischemia and baseline pulse amplitude, a measure of arterial tone (n = 2,369). Higher short-term exposure to air pollutants, including PM2.5, black carbon, and particle number was associated with higher baseline pulse amplitude. For example, higher 3-day average PM2.5 exposure was associated with 6.3% higher baseline pulse amplitude (95% confidence interval: 2.0, 10.9). However, there were no consistent associations between the air pollution exposures assessed and hyperemic response. Our findings in a community-based sample exposed to relatively low pollution levels suggest that short-term exposure to ambient particulate pollution is not associated with vasodilator response, but that particulate air pollution is associated with baseline pulse amplitude, suggesting potentially adverse alterations in baseline vascular tone or compliance. PMID:25100647

  12. The Influence of a Mouthpiece-Based Topography Measurement Device on Electronic Cigarette User's Plasma Nicotine Concentration, Heart Rate, and Subjective Effects Under Directed and Ad Libitum Use Conditions.

    PubMed

    Spindle, Tory R; Hiler, Marzena M; Breland, Alison B; Karaoghlanian, Nareg V; Shihadeh, Alan L; Eissenberg, Thomas

    2017-04-01

    Electronic cigarettes e-cigarettes aerosolize a liquid solution often containing nicotine. e-cigarette nicotine delivery may be influenced by user puffing behaviors ("puff topography"). E-cigarette puff topography can be recorded using mouthpiece-based computerized systems. The present study sought to examine the extent to which these systems influence e-cigarette nicotine delivery and other e-cigarette associated acute effects under ad libitum use conditions. Plasma nicotine concentration, heart rate, and subjective effects were assessed in 29 experienced e-cigarette users using their preferred e-cigarette battery and liquid (≥12mg/mL nicotine) in two sessions differing only by the presence of a mouthpiece-based device. In both sessions, participants completed a directed e-cigarette use bout (10 puffs, 30-s interpuff interval) and a 90-min ad libitum bout. Puff topography was recorded in the session with the topography mouthpiece. Plasma nicotine, heart rate, and subjective effects, aside from "Did the e-cigarette Taste Good?" were independent of topography measurement (higher mean taste ratings were observed in the no topography condition). Mean (SEM) plasma nicotine concentration following the ad libitum bout was 34.3ng/mL (4.9) in the no topography condition and 35.7ng/mL (4.3) in the topography condition. Longer puff durations, longer interpuff intervals, and larger puff volumes were observed in the ad libitum relative to the directed bout. E-cigarette use significantly increased plasma nicotine concentration and heart rate while suppressing abstinence symptoms. These effects did not differ when a topography mouthpiece was present. Future studies using ad libitum e-cigarette use bouts would facilitate understanding of e-cigarette toxicant yield. No prior study has examined whether mouthpiece-based topography recording devices influence e-cigarette associated nicotine delivery, heart rate, or subjective effects under ad libitum conditions or assessed ad libitum puff topography in experienced individuals using their preferred e-cigarette battery and liquid with a mouthpiece-based computerized device. E-cigarette use significantly increased plasma nicotine concentration and heart rate while suppressing abstinence symptoms. These effects did not differ when a topography mouthpiece was present. Ad libitum puff topography differed from puff topography recorded during directed puffing. These findings suggest that future studies using ad libitum use bouts would facilitate better understanding of e-cigarette toxicant yield. © The Author 2016. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Introduction of Two Novel Stiffness Parameters and Interpretation of Air Puff-Induced Biomechanical Deformation Parameters With a Dynamic Scheimpflug Analyzer.

    PubMed

    Roberts, Cynthia J; Mahmoud, Ashraf M; Bons, Jeffrey P; Hossain, Arif; Elsheikh, Ahmed; Vinciguerra, Riccardo; Vinciguerra, Paolo; Ambrósio, Renato

    2017-04-01

    To investigate two new stiffness parameters and their relationships with the dynamic corneal response (DCR) parameters and compare normal and keratoconic eyes. Stiffness parameters are defined as Resultant Pressure at inward applanation (A1) divided by corneal displacement. Stiffness parameter A1 uses displacement between the undeformed cornea and A1 and stiffness parameter highest concavity (HC) uses displacement from A1 to maximum deflection during HC. The spatial and temporal profiles of the Corvis ST (Oculus Optikgeräte, Wetzlar, Germany) air puff were characterized using hot wire anemometry. An adjusted air pressure impinging on the cornea at A1 (adjAP1) and an algorithm to biomechanically correct intraocular pressure based on finite element modelling (bIOP) were used for Resultant Pressure calculation (adjAP1 - bIOP). Linear regression analyses between DCR parameters and stiffness parameters were performed on a retrospective dataset of 180 keratoconic eyes and 482 normal eyes. DCR parameters from a subset of 158 eyes of 158 patients in each group were matched for bIOP and compared using t tests. A P value of less than .05 was considered statistically significant. All DCR parameters evaluated showed significant differences between normal and keratoconic eyes, except peak distance. Keratoconic eyes had lower stiffness parameter values, thinner pachymetry, shorter applanation lengths, greater absolute values of applanation velocities, earlier A1 times and later second applanation times, greater HC deformation amplitudes and HC deflection amplitudes, and lower HC radius of concave curvature (greater concave curvature). Most DCR parameters showed a significant relationship with both stiffness parameters in both groups. Keratoconic eyes demonstrated less resistance to deformation than normal eyes with similar IOP. The stiffness parameters may be useful in future biomechanical studies as potential biomarkers. [J Refract Surg. 2017;33(4):266-273.]. Copyright 2017, SLACK Incorporated.

  14. Evaluation of a rebound tonometer (Tonovet) in clinically normal cat eyes.

    PubMed

    Rusanen, Elina; Florin, Marion; Hässig, Michael; Spiess, Bernhard M

    2010-01-01

    To determine the accuracy of and to establish reference values for a rebound tonometer (Tonovet) in normal feline eyes, to compare it with an applanation tonometer (Tonopen Vet) and to evaluate the effect of topical anesthesia on rebound tonometry. Six enucleated eyes were used to compare both tonometers with direct manometry. Intraocular pressure (IOP) was measured in 100 cats to establish reference values for rebound tonometry. Of these, 22 cats were used to compare rebound tonometry with and without topical anesthesia and 33 cats to compare the rebound and applanation tonometers. All evaluated eyes were free of ocular disease. Both tonometers correlated well with direct manometry. The best agreement with the rebound tonometer was achieved between 25-50 mmHg. The applanation tonometer was accurate at pressures between 0 and 30 mmHg. The mean IOP in clinically normal cats was 20.74 mmHg with the rebound tonometer and 18.4 mmHg with the applanation tonometer. Topical anesthesia did not significantly affect rebound tonometry. As the rebound tonometer correlated well with direct manometry in the clinically important pressure range and was well tolerated by cats, it appears suitable for glaucoma diagnosis. The mean IOP obtained with the rebound tonometer was 2-3 mmHg higher than that measured with the applanation tonometer. This difference is within clinically acceptable limits, but indicates that the same type of tonometer should be used in follow-up examinations in a given cat.

  15. Comparison of Puff Topography, Toxicant Exposure, and Subjective Effects in Low- and High-Frequency Waterpipe Users: A Double-Blind, Placebo-Control Study

    PubMed Central

    Cobb, Caroline O.; Blank, Melissa D.; Morlett, Alejandra; Shihadeh, Alan; Jaroudi, Ezzat; Karaoghlanian, Nareg; Kilgalen, Barbara; Austin, Janet; Weaver, Michael F.

    2015-01-01

    Introduction: Clinical laboratory work among intermittent and daily waterpipe tobacco smokers has revealed significant risks for tobacco dependence and disease associated with waterpipe tobacco smoking (WTS). No studies have compared these groups directly. This study examined whether WTS frequency was associated with differential puff topography, toxicant exposure, and subjective response using a placebo-control design. Methods: Eighty participants reporting WTS of 2–5 episodes (LOW; n = 63) or ≥20 episodes (HIGH; n = 17) per month for ≥6 months completed 2 double-blind, counterbalanced 2-hr sessions that were preceded by ≥12hr of tobacco abstinence. Sessions differed by product smoked ad libitum for 45+ min: preferred brand/flavor of waterpipe tobacco (active) or a flavor-matched tobacco-free waterpipe product (placebo). Outcomes included puff topography, plasma nicotine, carboxyhemoglobin (COHb), and subjective response. Results: HIGH users had more puffs, shorter inter-puff-intervals, and a higher total puff volume for placebo relative to active, as well as relative to LOW users during placebo. Plasma nicotine concentrations increased when smoking active (but not placebo) with no significant differences between groups at 25min post-product administration. COHb increased significantly during all conditions; the largest increase was for HIGH users when smoking placebo. There was some evidence of higher baseline scores for nicotine/tobacco nicotine abstinence symptomology. Conclusions: Higher frequency waterpipe users may be more sensitive to the effects of waterpipe smoke nicotine content. Among HIGH users, higher baseline nicotine/tobacco abstinence symptoms may indicate greater nicotine dependence. These data support continued surveillance of WTS and development of dependence measures specific to this product. PMID:25257982

  16. A Programmable Smoke Delivery Device for PET Imaging with Cigarettes Containing 11C-nicotine

    PubMed Central

    Zuo, Yantao; Garg, Pradeep K; Nazih, Rachid; Garg, Sudha; Rose, Jed E; Murugesan, Thangaraju; Mukhin, Alexey G

    2017-01-01

    Introduction PET imaging with 11C-nicotine-loaded cigarettes is a valuable tool to directly assess fast nicotine kinetics and its neuropharmacological role in tobacco dependence. To eliminate variations among puffs inhaled by subjects, this work aimed to develop a programmable smoke delivery device (SDD) to produce highly reproducible and adjustable puffs of cigarette smoke for PET experiments. New method The SDD was built around a programmable syringe pump as a smoking machine to draw a puff of smoke from a 11C-nicotine-loaded cigarette and make it available for a subject to take the smoke into the mouth and then inhale it during PET data acquisition. Brain nicotine time activity curves and total body absorbed 11C-nicotine doses (TAD) were measured in smokers who inhaled a single puff of smoke via the SDD from a 11C-nicotine-loaded cigarette. Results Nearly identical brain nicotine kinetics were observed between participants who inhaled a puff of smoke through the SDD and those who inhaled directly from a cigarette. Comparison with existing methods This new device minimizes puff variations that exist with earlier smoke delivery apparatuses which could introduce confounding factors. Conclusions The SDD is effective in delivering 11C-nicotine from the study cigarettes. Despite a 2-sec increase in aging of smoke delivered through the SDD versus smoke taken directly from a cigarette, the difference in brain nicotine kinetics after 11C-nicotine delivery with and without use of the SDD is negligible. This refined device may be useful for future research on the deposition and pharmacokinetics of nicotine inhaled with tobacco smoke. PMID:28347784

  17. A programmable smoke delivery device for PET imaging with cigarettes containing 11C-nicotine.

    PubMed

    Zuo, Yantao; Garg, Pradeep K; Nazih, Rachid; Garg, Sudha; Rose, Jed E; Murugesan, Thangaraju; Mukhin, Alexey G

    2017-05-01

    PET imaging with 11 C-nicotine-loaded cigarettes is a valuable tool to directly assess fast nicotine kinetics and its neuropharmacological role in tobacco dependence. To eliminate variations among puffs inhaled by subjects, this work aimed to develop a programmable smoke delivery device (SDD) to produce highly reproducible and adjustable puffs of cigarette smoke for PET experiments. The SDD was built around a programmable syringe pump as a smoking machine to draw a puff of smoke from a 11 C-nicotine-loaded cigarette and make it available for a subject to take the smoke into the mouth and then inhale it during PET data acquisition. Brain nicotine time activity curves and total body absorbed 11 C-nicotine doses (TAD) were measured in smokers who inhaled a single puff of smoke via the SDD from a 11 C-nicotine-loaded cigarette. Nearly identical brain nicotine kinetics were observed between participants who inhaled a puff of smoke through the SDD and those who inhaled directly from a cigarette. This new device minimizes puff variations that exist with earlier smoke delivery apparatuses which could introduce confounding factors. The SDD is effective in delivering 11 C-nicotine from the study cigarettes. Despite a 2-s increase in aging of smoke delivered through the SDD versus smoke taken directly from a cigarette, the difference in brain nicotine kinetics after 11 C-nicotine delivery with and without use of the SDD is negligible. This refined device may be useful for future research on the deposition and pharmacokinetics of nicotine inhaled with tobacco smoke. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. A Real-Time Fast-Flow Tube Study of VOC and Particulate Emissions from Electronic, Potentially Reduced-Harm, Conventional, and Reference Cigarettes

    PubMed Central

    Blair, Sandra L.; Epstein, Scott A.; Nizkorodov, Sergey A.; Staimer, Norbert

    2015-01-01

    Tobacco-free electronic cigarettes (e-cigarettes), which are currently not regulated by the FDA, have become widespread as a “safe” form of smoking. One approach to evaluate the potential toxicity of e-cigarettes and other types of potentially “reduced-harm” cigarettes is to compare their emissions of volatile organic compounds (VOCs), including reactive organic electrophillic compounds such as acrolein, and particulate matter to those of conventional and reference cigarettes. Our newly designed fast-flow tube system enabled us to analyze VOC composition and particle number concentration in real-time by promptly diluting puffs of mainstream smoke obtained from different brands of combustion cigarettes and e-cigarettes. A proton transfer reaction time-of-flight mass spectrometer (PTRMS) was used to analyze real-time cigarette VOC emissions with a 1 s time resolution. Particles were detected with a condensation particle counter (CPC). This technique offers real-time analysis of VOCs and particles in each puff without sample aging and does not require any sample pretreatment or extra handling. Several important determining factors in VOC and particle concentration were investigated: (1) puff frequency; (2) puff number; (3) tar content; (4) filter type. Results indicate that electronic cigarettes are not free from acrolein and acetaldehyde emissions and produce comparable particle number concentrations to those of combustion cigarettes, more specifically to the 1R5F reference cigarette. Unlike conventional cigarettes, which emit different amounts of particles and VOCs each puff, there was no significant puff dependence in the e-cigarette emissions. Charcoal filter cigarettes did not fully prevent the emission of acrolein and other VOCs. PMID:26726281

  19. Changes in puffing behavior among smokers who switched from tobacco to electronic cigarettes

    PubMed Central

    Lee, Yong Hee; Gawron, Michal; Goniewicz, Maciej Lukasz

    2015-01-01

    Introduction Nicotine intake from electronic cigarette (e-cigarettes) increases with user’s experience. This suggests that smokers who switched from tobacco to electronic cigarettes compensate for nicotine over the time to get as much nicotine as they need. One of the mechanism by which smokers may compensate for nicotine is by modifying their puffing behavior. The aim of the study was to assess the changes in puffing behavior after switching from conventional to electronic cigarettes among regular smokers. Materials and Methods Twenty smokers (11 female, aged 31±10, CPD 16±8, FTND 4±3, and exhaled CO 16±17 (mean±SD)) who were naïve to e-cigarettes participated in this study. They were asked to substitute their regular tobacco cigarettes with first generation e-cigarettes (labelled 18 mg nicotine) for two weeks. Puffing topography (number of puffs, puff volume, intervals between puffs, and average puff flow rate) was measured at the initial use (baseline), as well as after one and two weeks of product use. We tested changes in puffing topography outcomes using repeated measures ANOVA. Results We found that after one week of using e-cigarettes, participants significantly increased the average time they puffed on e-cigarettes from 2.2±0.1 (mean±SEM) to 3.1±0.3 sec (p<0.05). The average puff flow rate decreased from 30.6±2.3 to 25.1±1.8 ml/sec after one week of e-cigarette use (p<0.05). Conclusions Our data show that smokers modify their puffing behavior after switching from tobacco to electronic cigarettes by taking longer and slower puffs. The potential reason for changing puffing behavior is to compensate for less efficient nicotine delivery from e-cigarettes. PMID:25930009

  20. Changes in puffing behavior among smokers who switched from tobacco to electronic cigarettes.

    PubMed

    Lee, Yong Hee; Gawron, Michal; Goniewicz, Maciej Lukasz

    2015-09-01

    Nicotine intake from electronic cigarette (e-cigarettes) increases with user's experience. This suggests that smokers who switched from tobacco to electronic cigarettes compensate for nicotine over time to get as much nicotine as they need. One of the mechanisms by which smokers may compensate for nicotine is by modifying their puffing behavior. The aim of the study was to assess the changes in puffing behavior after switching from conventional to electronic cigarettes among regular smokers. Twenty smokers (11 female, aged 31±10, CPD 16±8, FTND 4±3, and exhaled CO 16±17 (mean±SD)) who were naïve to e-cigarettes participated in this study. They were asked to substitute their regular tobacco cigarettes with first generation e-cigarettes (labeled 18mg nicotine) for two weeks. Puffing topography (number of puffs, puff volume, intervals between puffs, and average puff flow rate) was measured at the initial use (baseline), as well as after one and two weeks of product use. We tested changes in puffing topography outcomes using repeated measures ANOVA. We found that after one week of using e-cigarettes, participants significantly increased the average time they puffed on e-cigarettes from 2.2±0.1 (mean±SEM) to 3.1±0.3s (p<0.05). The average puff flow rate decreased from 30.6±2.3 to 25.1±1.8ml/s after one week of e-cigarette use (p<0.05). Our data show that smokers modify their puffing behavior after switching from tobacco to electronic cigarettes by taking longer and slower puffs. The potential reason for changing puffing behavior is to compensate for less efficient nicotine delivery from e-cigarettes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Maximize Liquid Oil Production from Shale Oil and Gas Condensate Reservoirs by Cyclic Gas Injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, James; Li, Lei; Yu, Yang

    The current technology to produce shale oil reservoirs is the primary depletion using fractured wells (generally horizontal wells). The oil recovery is less than 10%. The prize to enhance oil recovery (EOR) is big. Based on our earlier simulation study, huff-n-puff gas injection has the highest EOR potential. This project was to explore the potential extensively and from broader aspects. The huff-n-puff gas injection was compared with gas flooding, water huff-n-puff and waterflooding. The potential to mitigate liquid blockage was also studied and the gas huff-n-puff method was compared with other solvent methods. Field pilot tests were initiated but terminatedmore » owing to the low oil price and the operator’s budget cut. To meet the original project objectives, efforts were made to review existing and relevant field projects in shale and tight reservoirs. The fundamental flow in nanopores was also studied.« less

  2. Dosage-based parameters for characterization of puff dispersion results.

    PubMed

    Berbekar, Eva; Harms, Frank; Leitl, Bernd

    2015-01-01

    A set of parameters is introduced to characterize the dispersion of puff releases based on the measured dosage. These parameters are the dosage, peak concentration, arrival time, peak time, leaving time, ascent time, descent time and duration. Dimensionless numbers for the scaling of the parameters are derived from dimensional analysis. The dimensionless numbers are tested and confirmed based on a statistically representative wind tunnel dataset. The measurements were carried out in a 1:300 scale model of the Central Business District in Oklahoma City. Additionally, the effect of the release duration on the puff parameters is investigated. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Background: Preflight Screening, In-flight Capabilities, and Postflight Testing

    NASA Technical Reports Server (NTRS)

    Gibson, Charles Robert; Duncan, James

    2009-01-01

    Recommendations for minimal in-flight capabilities: Retinal Imaging - provide in-flight capability for the visual monitoring of ocular health (specifically, imaging of the retina and optic nerve head) with the capability of downlinking video/still images. Tonometry - provide more accurate and reliable in-flight capability for measuring intraocular pressure. Ultrasound - explore capabilities of current on-board system for monitoring ocular health. We currently have limited in-flight capabilities on board the International Space Station for performing an internal ocular health assessment. Visual Acuity, Direct Ophthalmoscope, Ultrasound, Tonometry(Tonopen):

  4. Multimodality of Ca2+ signaling in rat atrial myocytes.

    PubMed

    Morad, Martin; Javaheri, Ashkan; Risius, Tim; Belmonte, Steve

    2005-06-01

    It has been suggested that the multiplicity of Ca(2+) signaling pathways in atrial myocytes may contribute to the variability of its function. This article reports on a novel Ca(2+) signaling cascade initiated by mechanical forces induced by "puffing" of solution onto the myocytes. Ca(i) transients were measured in fura-2 acetoxymethyl (AM) loaded cells using alternating 340- and 410-nm excitation waves at 1.2 kHz. Pressurized puffs of bathing solutions, applied by an electronically controlled micro-barrel system, activated slowly (approximately 300 ms) developing Ca(i) transients that lasted 1,693 +/- 68 ms at room temperature. Subsequent second and third puffs, applied at approximately 20 s intervals activated significantly smaller or no Ca(i) transients. Puff-triggered Ca(i) transients could be reactivated once again following caffeine (10 mM)-induced release of Ca(2+) from sarcoplasmic reticulum (SR). Puff-triggered Ca(i) transients were independent of [Ca(2+)](o), and activation of voltage-gated Ca(2+) or cationic stretch channels or influx of Ca(2+) on Na(+)/Ca(2+)exchanger, because puffing solution containing no Ca(2+), 10 microM diltiazem, 1 mM Cd(2+), 5 mM Ni(2+), or 100 microM Gd(3+) failed to suppress them. Puff-triggered Ca(i) transients were enhanced in paced compared to quiescent myocytes. Electrically activated Ca(i) transients triggered during the time course of puff-induced transients were unaltered, suggesting functionally separate Ca(2+) pools. Contribution of inositol 1,4,5-triphosphate (IP(3))-gated or mitochondrial Ca(2+) pools or modulation of SR stores by nitric oxide/nitric oxide synthase (NO/NOS) signaling were evaluated using 0.5 to 500 microM 2-aminoethoxydiphenyl borate (2-APB) and 0.1 to 1 microM carbonylcyanide-p-trifluoromethoxyphenylhydrazone (FCCP), and 1 mM Nomega-Nitro-L-arginine methyl ester (L-NAME) and 7-nitroindizole, respectively. Only FCCP appeared to significantly suppress the puff-triggered Ca(i) transients. It was concluded that neither Ca(2+) influx nor depolarization was required for activation of this signaling pathway. These studies suggest that pressurized puffs of solutions activate a mechanically sensitive receptor, which signals in turn the release of Ca(2+) from a limited Ca(2+) store of mitochondria. How mechanical forces are sensed and transmitted to mitochondria to induce Ca(2+) release and what role such a Ca(2+) signaling pathway plays in the physiology or pathophysiology of the heart remain to be worked out.

  5. Flavoring Chemicals and Aldehydes in E-Cigarette Emissions.

    PubMed

    Klager, Skylar; Vallarino, Jose; MacNaughton, Piers; Christiani, David C; Lu, Quan; Allen, Joseph G

    2017-09-19

    Regulations on e-cigarettes in the U.S. do not provide guidelines on the chemical content of e-cigarette liquids. We evaluated emissions of aldehydes and flavoring chemicals in e-cigarette vapor under typical usage conditions. We selected 24 e-cigarette flavors from the top selling disposable e-cigarette brands. E-cigarettes were connected to a pump drawing air for two second puffs with sixty-second intervals between puffs. The vapor was analyzed for the presence of aldehydes using high-performance liquid chromatography-ultraviolet detector and for the presence of flavoring chemicals with gas chromatography and an electron capture detector. All e-cigarette emissions tested contained at least one aldehyde and/or flavoring chemical on either the FEMA "High Priority Chemicals" or FDA Harmful and Potentially Harmful Constituents lists when sampled at typical usage conditions. Diacetyl, a known respiratory hazard, along with acetoin, were the most prevalent of the flavoring chemicals in e-cigarette vapor, being found in more than 60% of samples. The presence of propionaldehyde, acetaldehyde and formaldehyde were correlated, corroborating previous work suggesting thermal degradation as a pathway for aldehyde generation in e-cigarette vapors. Median formaldehyde concentrations of 626 μg/m 3 in e-cigarette vapor exceed the ACGIH maximum concentrations allowable for workers of 370 μg/m 3 .

  6. Elements including metals in the atomizer and aerosol of disposable electronic cigarettes and electronic hookahs.

    PubMed

    Williams, Monique; Bozhilov, Krassimir; Ghai, Sanjay; Talbot, Prue

    2017-01-01

    Our purpose was to quantify 36 inorganic chemical elements in aerosols from disposable electronic cigarettes (ECs) and electronic hookahs (EHs), examine the effect of puffing topography on elements in aerosols, and identify the source of the elements. Thirty-six inorganic chemical elements and their concentrations in EC/EH aerosols were determined using inductively coupled plasma optical emission spectroscopy, and their source was identified by analyzing disassembled atomizers using scanning electron microscopy and energy dispersive X-ray spectroscopy. Of 36 elements screened, 35 were detected in EC/EH aerosols, while only 15 were detected in conventional tobacco smoke. Some elements/metals were present in significantly higher concentrations in EC/EH aerosol than in cigarette smoke. Concentrations of particular elements/metals within EC/EH brands were sometimes variable. Aerosols generated at low and high air-flow rates produced the same pattern of elements, although the total element concentration decreased at the higher air flow rate. The relative amount of elements in the first and last 60 puffs was generally different. Silicon was the dominant element in aerosols from all EC/EH brands and in cigarette smoke. The elements appeared to come from the filament (nickel, chromium), thick wire (copper coated with silver), brass clamp (copper, zinc), solder joints (tin, lead), and wick and sheath (silicon, oxygen, calcium, magnesium, aluminum). Lead was identified in the solder and aerosol of two brands of EHs (up to 0.165 μg/10 puffs). These data show that EC/EH aerosols contain a mixture of elements, including heavy metals, with concentrations often significantly higher than in conventional cigarette smoke. While the health effects of inhaling mixtures of heated metals is currently not known, these data will be valuable in future risk assessments involving EC/EH elements/metals.

  7. Ocular manifestation in Marfan syndrome: corneal biomechanical properties relate to increased systemic score points.

    PubMed

    Scheibenberger, Dido; Frings, Andreas; Steinberg, Johannes; Schüler, Helke; Druchkiv, Vasyl; Katz, Toam; von Kodolitsch, Yskert; Linke, Stephan

    2018-06-01

    To evaluate corneal deformation to an air puff as a new noninvasive tool to document disease status in Marfan syndrome (MFS) METHODS: Prospective observational cohort study. We included patients diagnosed with MFS who had their routine cardiovascular follow-up and applied the revised Ghent nosology to define two subgroups according to a high (≥ 7) and a low (< 7 points) systemic score. Dynamic Scheimpflug-based biomechanical analyses (CorvisST® [CST; Oculus GmbH]) were performed. The main outcome measure was the displacement of the corneal apex as given by the parameters highest concavity (HC; in ms), peak distance (PD; in mm), and highest concavity deformation amplitude (DA; mm). Forty-three eyes of 43 individuals (19 female, 24 male; mean age 42.0 ± 12.0 years, range 18-67 years) diagnosed with MFS were included. Applying the Ghent criteria, 21 patients had an advanced systemic score of ≥ 7, and 22 had score points < 7. There were no differences in age or sex between both groups. In contrast, HC was faster (P = 0.004), and PD (P < 0.001) was longer in those individuals with systemic score ≥ 7; maximum DA did not result in a statistically significant difference between the groups (P = 0.250). In vivo noninvasive biomechanical analyses with CST offer a new, non-invasive method to identify pathologic corneal deformation responses in adults with MFS. In the future, corneal deformation to an air puff could thus assist early identification of patients with high Ghent score as an adjunct to existing diagnostic tests.

  8. Pharyngeal chemosensitivity in patients with obstructive sleep apnea and healthy subjects.

    PubMed

    Heiser, Clemens; Zimmermann, Ingo; Sommer, J Ulrich; Hörmann, Karl; Herr, Raphael M; Stuck, Boris A

    2013-09-01

    Signs of pharyngeal neurodegeneration have been detected in patients with obstructive sleep apnea (OSA). Along with this neurodegeneration, a decreased pharyngeal sensitivity to mechanical stimulation has been described. The decreased sensitivity may play a role in the pathophysiology of this disease. The aim of the study was to investigate the chemosensitivity of the pharyngeal mucosa in patients with OSA compared with controls. Healthy controls and patients with OSA (age: 30-60 years) were included. Testing of oropharyngeal chemosensitivity was performed with subjective intensity ratings of capsaicin (SIR, visual analogue scale 0-10), air puffs (presented with an olfactometer), and stimulation with CO2 at the posterior pharyngeal wall. A 2-point discrimination test at the soft palate, an intensity rating of capsaicin at the tongue, and a nasal lateralization test were performed. Twenty-six patients with OSA and 18 healthy controls were included. No differences were detected in the SIR of capsaicin at the tongue or in the nasal lateralization test. At the pharynx, a decreased sensitivity to capsaicin (OSA: 6.8 ± 2.3; healthy control: 8.6 ± 1.3), air puffs (OSA: 2.8 ± 1.9; healthy control: 4.2 ± 1.6), and stimulation with CO2 (OSA: 1.5 ± 1.7; healthy control: 2.8 ± 1.8) were demonstrated in patients with OSA (all P < 0.05). Two-point discrimination at the soft palate was reduced with statistical significance in the OSA group (OSA: 11.5 ± 5.4 mm; healthy control: 5.0 ± 2.4 mm). The results suggest reduced pharyngeal chemosensitivity in OSA patients in addition to the reduced mechanical pharyngeal sensitivity shown with 2-point discrimination. This demonstrates peripheral neurodegeneration in the context of this disease.

  9. Impact assessment of PM10 cement plants emissions on urban air quality using the SCIPUFF dispersion model.

    PubMed

    Leone, Vincenzo; Cervone, Guido; Iovino, Pasquale

    2016-09-01

    The Second-order Closure Integrated Puff (SCIPUFF) model was used to study the impact on urban air quality caused by two cement plants emissions located near the city of Caserta, Italy, during the entire year of 2015. The simulated and observed PM10 concentrations were compared using three monitoring stations located in urban and sub-urban area of Caserta city. Both simulated and observed concentrations are shown to be highest in winter, lower in autumn and spring and lowest in summer. Model results generally follow the pattern of the observed concentrations but have a systematic under-prediction of the concentration values. Measures of the bias, NMSE and RMSE indicate a good correlation between observed and estimated values. The SCIPUFF model data analysis suggest that the cement plants are major sources for the measured PM10 values and are responsible for the deterioration of the urban air quality in the city of Caserta.

  10. EFFECTS OF WIND SHEAR ON POLLUTION DISPERSION. (R827929)

    EPA Science Inventory

    Using an accurate numerical method for simulating the advection and diffusion of pollution puffs, it is demonstrated that point releases of pollution grow into a shape reflecting the vertical wind shear profile experienced by the puff within a time scale less than 4 h. Fo...

  11. Liquid oil production from shale gas condensate reservoirs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, James J.

    A process of producing liquid oil from shale gas condensate reservoirs and, more particularly, to increase liquid oil production by huff-n-puff in shale gas condensate reservoirs. The process includes performing a huff-n-puff gas injection mode and flowing the bottom-hole pressure lower than the dew point pressure.

  12. Potential bacterial contamination of eyedrops used for tonometry.

    PubMed

    Palmberg, R; Gutierrez, Y S; Miller, D; Feuer, W J; Anderson, D R

    1994-05-15

    We compared the potential for bacterial contamination of a proparacaine hydrochloride solution preserved with benzalkonium chloride, which is used with fluorescein paper for tonometry, to that of a fluorescein-benoxinate hydrochloride combination solution preserved with chlorobutanol. We contaminated bottles of each solution with Pseudomonas aeruginosa or Staphylococcus aureus (10(7) organisms per milliliter of eyedrop solution). From the fluorescein-benoxinate hydrochloride solution, Staphylococcus organisms were cultured in declining numbers over time, with a half-life of nine seconds, and no Staphylococcus organisms were recovered after five minutes. Pseudomonas organisms disappeared from this solution within 15 seconds. Neither species was viable after 15 seconds in the proparacaine hydrochloride solution. Additionally, we cultured 12 bottles of fluorescein-benoxinate hydrochloride and 15 bottles of proparacaine hydrochloride that had been in use in the clinic for one month. No organisms were recovered from a drop dispensed from any bottle or from the tips, caps, rims, or solution from within any bottle, except that five colonies of Staphylococcus grew from the external rim of one bottle. We conclude that both solutions sterilize themselves rapidly and effectively. Either may be used safely for tonometry.

  13. Development of a new gas puff imaging diagnostic on the HL-2A tokamak

    NASA Astrophysics Data System (ADS)

    Yuan, B.; Xu, M.; Yu, Y.; Zang, L.; Hong, R.; Chen, C.; Wang, Z.; Nie, L.; Ke, R.; Guo, D.; Wu, Y.; Long, T.; Gong, S.; Liu, H.; Ye, M.; Duan, X.; HL-2A team

    2018-03-01

    A new gas puff imaging (GPI) diagnostic has been developed on the HL-2A tokamak to study two-dimensional plasma edge turbulence in poloidal vs. radial plane. During a discharge, neutral helium or deuterium gas is puffed at the edge of the plasma through a rectangular multi\

  14. An Analysis of a Puff Dispersion Model for a Coastal Region.

    DTIC Science & Technology

    1982-06-01

    gril is determined by computing their movement for a finite time step using a measured wind field. The growth and buoyancy of the puffs are computed...advection step. The grid concentrations can be allowed to accumulate or simply be updated with the lat- est instantaneous value. & minimum gril concentration

  15. In vivo effects of ecdysterone on puff formation, and RNA and protein synthesis in the salivary glands of Rhynchosciara americana.

    PubMed

    Alvarenga, C A; Winter, C E; Stocker, A J; Pueyo, M T; Lara, F J

    1991-01-01

    1. Fourth-instar larvae of Rhynchosciara americana were injected with the insect molting hormone, ecdysterone, giving final hemolymph concentrations from 4.46 to 223 microM. 2. Induction of the DNA puff, B2b, in the proximal (S1) region of the salivary glands of Rhynchosciara americana by 22.6 microM ecdysterone, was accompanied by the production of an mRNA and a polypeptide with the same characteristics as B2b products produced during normal development. This mRNA and polypeptide were restricted to the proximal region of the gland, as is the B2b puff. 3. Synthesis of other poly(A)+RNAs was also stimulated in S1 by ecdysterone, and other puffs that appear during normal development were induced. However, rRNA production in S1 goes through a pattern of inhibition, followed by recovery when B2b is puffed, and subsequent inhibition. 4. Low molecular weight RNA, with a peak in the region of 4S, is stimulated after ecdysterone administration.

  16. Week Long Topography Study of Young Adults Using Electronic Cigarettes in Their Natural Environment.

    PubMed

    Robinson, R J; Hensel, E C; Roundtree, K A; Difrancesco, A G; Nonnemaker, J M; Lee, Y O

    2016-01-01

    Results of an observational, descriptive study quantifying topography characteristics of twenty first generation electronic nicotine delivery system users in their natural environment for a one week observation period are presented. The study quantifies inter-participant variation in puffing topography between users and the intra-participant variation for each user observed during one week of use in their natural environment. Puff topography characteristics presented for each user include mean puff duration, flow rate and volume for each participant, along with descriptive statistics of each quantity. Exposure characteristics including the number of vaping sessions, total number of puffs and cumulative volume of aerosol generated from ENDS use (e-liquid aerosol) are reported for each participant for a one week exposure period and an effective daily average exposure. Significant inter-participant and intra-participant variation in puff topography was observed. The observed range of natural use environment characteristics is used to propose a set of topography protocols for use as command inputs to drive machine-puffed electronic nicotine delivery systems in a controlled laboratory environment.

  17. Week Long Topography Study of Young Adults Using Electronic Cigarettes in Their Natural Environment

    PubMed Central

    Roundtree, K. A.; Difrancesco, A. G.; Nonnemaker, J. M.; Lee, Y. O.

    2016-01-01

    Results of an observational, descriptive study quantifying topography characteristics of twenty first generation electronic nicotine delivery system users in their natural environment for a one week observation period are presented. The study quantifies inter-participant variation in puffing topography between users and the intra-participant variation for each user observed during one week of use in their natural environment. Puff topography characteristics presented for each user include mean puff duration, flow rate and volume for each participant, along with descriptive statistics of each quantity. Exposure characteristics including the number of vaping sessions, total number of puffs and cumulative volume of aerosol generated from ENDS use (e-liquid aerosol) are reported for each participant for a one week exposure period and an effective daily average exposure. Significant inter-participant and intra-participant variation in puff topography was observed. The observed range of natural use environment characteristics is used to propose a set of topography protocols for use as command inputs to drive machine-puffed electronic nicotine delivery systems in a controlled laboratory environment. PMID:27736944

  18. Efficient Neutron Production from a Novel Configuration of Deuterium Gas-Puff Z-Pinch

    NASA Astrophysics Data System (ADS)

    Klir, D.; Kubes, P.; Rezac, K.; Cikhardt, J.; Kravarik, J.; Sila, O.; Shishlov, A. V.; Kovalchuk, B. M.; Ratakhin, N. A.; Kokshenev, V. A.; Labetsky, A. Yu.; Cherdizov, R. K.; Fursov, F. I.; Kurmaev, N. E.; Dudkin, G. N.; Nechaev, B. A.; Padalko, V. N.; Orcikova, H.; Turek, K.

    2014-03-01

    A novel configuration of a deuterium z pinch has been used to generate fusion neutrons. Injecting an outer hollow cylindrical plasma shell around an inner deuterium gas puff, neutron yields from DD reactions reached Yn=(2.9±0.3)×1012 at 700 ns implosion time and 2.7 MA current. Such a neutron yield means a tenfold increase in comparison with previous deuterium gas puff experiments at the same current generator. The increase of beam-target yields was obtained by a larger amount of current assembled on the z-pinch axis, and subsequently by higher induced voltage and higher energies of deuterons. A stack of CR-39 track detectors on the z-pinch axis showed hydrogen ions up to 38 MeV. Maximum neutron energies of 15 and 22 MeV were observed by radial and axial time-of-flight detectors, respectively. The number of DD neutrons per one joule of stored plasma energy approached 5×107. This implies that deuterium gas puff z pinches belong to the most efficient plasma-based sources of DD neutrons.

  19. Nicotine and Carbon Monoxide Exposure from Inhalation of Cigarillo Smoke

    PubMed Central

    Koszowski, Bartosz; Rosenberry, Zachary R.; Kanu, Alieu; Viray, Lauren C.; Potts, Jennifer L.; Pickworth, Wallace B.

    2015-01-01

    Background There has been an increase in the use of cigarillos in the US. People who smoke cigarillos typically also regularly smoke cigarettes (dual users). Methods We compared puffing topography, biomarkers of acute exposure [exhaled carbon monoxide (COex) and plasma nicotine] and physiologic effects from usual brand cigarette and Black & Mild cigarillo smoking in dual users (N=23) in two laboratory sessions. Results Participants (21 men) smoked an average of 17.5 cigarettes/day. Cigarillo consumption varied widely from as few as 1/week to daily. Participants were highly nicotine dependent (average FTND score: 6.3). There were statistically significant differences in smoking behavior between cigarette and cigarillo smoking in time to smoke, number of puffs, and total puff volume (all P<0.001). Average puff duration, interpuff interval average puff volume, and puff velocity did not differ between cigarettes and cigarillos. Nicotine boost was similar after both cigarettes and cigarillos. COex boost was significantly greater after cigarillo smoking compared to cigarette smoking (P<0.001). Conclusions The smoking pattern and exposure profile indicate that dual users inhale cigarillo smoke just as they inhale cigarette smoke thereby exposing themselves to considerable amounts of nicotine and other components of tobacco smoke. COex exposure results imply that cigarillo smoking may be associated with higher exposure to smoke-delivered volatile components of mainstream cigarillo smoke including carcinogens when compared to cigarettes. Impact The findings that cigarillos and cigarettes are smoked similarly in dual users are relevant to health and regulatory considerations on cigar products. PMID:26459155

  20. Smoking Topography among Korean Smokers: Intensive Smoking Behavior with Larger Puff Volume and Shorter Interpuff Interval.

    PubMed

    Kim, Sungroul; Yu, Sol

    2018-05-18

    The difference of smoker's topography has been found to be a function many factors, including sex, personality, nicotine yield, cigarette type (i.e., flavored versus non-flavored) and ethnicity. We evaluated the puffing behaviors of Korean smokers and its association with smoking-related biomarker levels. A sample of 300 participants was randomly recruited from metropolitan areas in South Korea. Topography measures during a 24-hour period were obtained using a CReSS pocket device. Korean male smokers smoked two puffs less per cigarette compared to female smokers (15.0 (13.0⁻19.0) vs. 17.5 (15.0⁻21.0) as the median (Interquartile range)), but had a significantly larger puff volume (62.7 (52.7⁻75.5) mL vs. 53.5 (42.0⁻64.2) mL); p = 0.012). The interpuff interval was similar between men and women (8.9 (6.5⁻11.2) s vs. 8.3 (6.2⁻11.0) s; p = 0.122) but much shorter than other study results. A dose-response association ( p = 0.0011) was observed between daily total puff volumes and urinary cotinine concentrations, after controlling for sex, age, household income level and nicotine addiction level. An understanding of the difference of topography measures, particularly the larger puff volume and shorter interpuff interval of Korean smokers, may help to overcome a potential underestimation of internal doses of hazardous byproducts of smoking.

  1. Comparison of True and Smoothed Puff Profile Replication on Smoking Behavior and Mainstream Smoke Emissions

    PubMed Central

    2015-01-01

    To estimate exposures to smokers from cigarettes, smoking topography is typically measured and programmed into a smoking machine to mimic human smoking, and the resulting smoke emissions are tested for relative levels of harmful constituents. However, using only the summary puff data—with a fixed puff frequency, volume, and duration—may underestimate or overestimate actual exposure to smoke toxins. In this laboratory study, we used a topography-driven smoking machine that faithfully reproduces a human smoking session and individual human topography data (n = 24) collected during previous clinical research to investigate if replicating the true puff profile (TP) versus the mathematically derived smoothed puff profile (SM) resulted in differences in particle size distributions and selected toxic/carcinogenic organic compounds from mainstream smoke emissions. Particle size distributions were measured using an electrical low pressure impactor, the masses of the size-fractionated fine and ultrafine particles were determined gravimetrically, and the collected particulate was analyzed for selected particle-bound, semivolatile compounds. Volatile compounds were measured in real time using a proton transfer reaction-mass spectrometer. By and large, TP levels for the fine and ultrafine particulate masses as well as particle-bound organic compounds were slightly lower than the SM concentrations. The volatile compounds, by contrast, showed no clear trend. Differences in emissions due to the use of the TP and SM profiles are generally not large enough to warrant abandoning the procedures used to generate the simpler smoothed profile in favor of the true profile. PMID:25536227

  2. Short-term exposure to air pollution and digital vascular function.

    PubMed

    Ljungman, Petter L; Wilker, Elissa H; Rice, Mary B; Schwartz, Joel; Gold, Diane R; Koutrakis, Petros; Vita, Joseph A; Mitchell, Gary F; Vasan, Ramachandran S; Benjamin, Emelia J; Mittleman, Murray A; Hamburg, Naomi M

    2014-09-01

    We investigated associations between ambient air pollution and microvessel function measured by peripheral arterial tonometry between 2003 and 2008 in the Framingham Heart Study Offspring and Third Generation Cohorts. We measured particulate matter with aerodynamic diameter ≤2.5 µm (PM2.5), black carbon, sulfates, particle number, nitrogen oxides, and ozone by using fixed monitors, and we determined moving averages for 1-7 days preceding vascular testing. We examined associations between these exposures and hyperemic response to ischemia and baseline pulse amplitude, a measure of arterial tone (n = 2,369). Higher short-term exposure to air pollutants, including PM2.5, black carbon, and particle number was associated with higher baseline pulse amplitude. For example, higher 3-day average PM2.5 exposure was associated with 6.3% higher baseline pulse amplitude (95% confidence interval: 2.0, 10.9). However, there were no consistent associations between the air pollution exposures assessed and hyperemic response. Our findings in a community-based sample exposed to relatively low pollution levels suggest that short-term exposure to ambient particulate pollution is not associated with vasodilator response, but that particulate air pollution is associated with baseline pulse amplitude, suggesting potentially adverse alterations in baseline vascular tone or compliance. © The Author 2014. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Combined varenicline and naltrexone treatment reduces smoking topography intensity in heavy-drinking smokers.

    PubMed

    Roche, Daniel J O; Bujarski, Spencer; Hartwell, Emily; Green, ReJoyce; Ray, Lara A

    2015-07-01

    Heavy drinking smokers constitute a distinct sub-population of smokers for whom traditional smoking cessation therapies may not be effective. Recent evidence suggested that combined varenicline (VAR) and naltrexone (NTX) therapy may be more efficacious than either monotherapy alone in reducing smoking and drinking-related behavior in this population. The manner in which individuals smoke a cigarette (i.e., smoking topography) may be predictive of smoking cessation outcomes, yet the effects of smoking pharmacotherapies on puffing behavior have not been thoroughly examined. Therefore, the current double-blind medication study examined the effects of VAR alone (1mg BID), low dose NTX alone (25mg QD), the combination of VAR+NTX, and placebo on smoking topography measures in heavy drinking, non-treatment seeking daily smokers (n=120). After a 9-day titration period, participants completed a laboratory session in which they smoked their first cigarette of the day using a smoking topography device following 12h of nicotine abstinence and consumption of an alcoholic beverage (BrAC=0.06g/dl). The primary measures were puff count, volume, duration, and velocity and inter-puff interval (IPI). Independent of medication group, puff velocity and IPI increased, while puff volume and duration decreased, over the course of the cigarette. The active medication groups, vs. the placebo group, had significantly blunted puff duration and velocity slopes over the course of the cigarette, and this effect was particularly evident in the VAR+NTX group. Additionally, the VAR+NTX group demonstrated lower average IPI than the monotherapy groups and lower average puff volume than all other groups. These results suggest that smoking pharmacotherapies, particularly the combination of VAR+NTX, alter smoking topography in heavy drinking smokers, producing a pattern of less intense puffing behavior. As smoking topography has been predictive of the ability to quit smoking, future studies should examine how smoking pharmacotherapies' effects on puffing behavior relate to smoking cessation outcomes. Copyright © 2015. Published by Elsevier Inc.

  4. Combined Varenicline and naltrexone treatment reduces smoking topography intensity in heavy-drinking smokers

    PubMed Central

    Roche, Daniel J.O.; Bujarski, Spencer; Hartwell, Emily; Green, ReJoyce; Ray, Lara A.

    2015-01-01

    Heavy drinking smokers constitute a distinct sub-population of smokers for whom traditional smoking cessation therapies may not be effective. Recent evidence suggested that combined varenicline (VAR) and naltrexone (NTX) therapy may be more efficacious than either monotherapy alone in reducing smoking and drinking-related behavior in this population. The manner in which individuals smoke a cigarette (i.e., smoking topography) may be predictive of smoking cessation outcomes, yet the effects of smoking pharmacotherapies on puffing behavior have not been thoroughly examined. Therefore, the current double-blind medication study examined the effects of VAR alone (1mg BID), low dose NTX alone (25mg QD), the combination of VAR+NTX, and placebo on smoking topography measures in heavy drinking, non-treatment seeking daily smokers (n=120). After a 9-day titration period, participants completed a laboratory session in which they smoked their first cigarette of the day using a smoking topography device following 12-hrs of nicotine abstinence and consumption of an alcoholic beverage (BrAC = 0.06 g/dl). The primary measures were puff count, volume, duration, and velocity and inter-puff interval (IPI). Independent of medication group, puff velocity and IPI increased, while puff volume and duration decreased, over the course of the cigarette. The active medication groups, vs. the placebo group, had significantly blunted puff duration and velocity slopes over the course of the cigarette, and this effect was particularly evident in the VAR+NTX group. Additionally, the VAR+NTX group demonstrated lower average IPI than the monotherapy groups and lower average puff volume than all other groups. These results suggest that smoking pharmacotherapies, particularly the combination of VAR+NTX, alter smoking topography in heavy drinking smokers, producing a pattern of less intense puffing behavior. As smoking topography has been predictive of the ability to quit smoking, future studies should examine how smoking pharmacotherapies’ effects on puffing behavior relate to smoking cessation outcomes. PMID:25933795

  5. Fluorescence Fluctuations and Equivalence Classes of Ca 2+ Imaging Experiments

    PubMed Central

    Piegari, Estefanía; Lopez, Lucía; Perez Ipiña, Emiliano; Ponce Dawson, Silvina

    2014-01-01

    release into the cytosol through inositol 1,4,5-trisphosphate receptors (IP3Rs) plays a relevant role in numerous physiological processes. IP3R-mediated signals involve -induced -release (CICR) whereby release through one open IP3R induces the opening of other channels. IP3Rs are apparently organized in clusters. The signals can remain localized (i.e., puffs) if CICR is limited to one cluster or become waves that propagate between clusters. puffs are the building blocks of waves. Thus, there is great interest in determining puff properties, especially in view of the current controversy on the spatial distribution of activatable IP3Rs. puffs have been observed in intact cells with optical techniques proving that they are intrinsically stochastic. Obtaining a correct picture of their dynamics then entails being able to detect the whole range of puff sizes. puffs are observed using visible single-wavelength dyes, slow exogenous buffers (e.g., EGTA) to disrupt inter-cluster CICR and UV-photolyzable caged IP3. Single-wavelength dyes increase their fluorescence upon calcium binding producing images that are strongly dependent on their kinetic, transport and photophysical properties. Determining the artifacts that the imaging setting introduces is particularly relevant when trying to analyze the smallest signals. In this paper we introduce a method to estimate the expected signal-to-noise ratio of imaging experiments that use single-wavelength dyes. The method is based on the Number and Brightness technique. It involves the performance of a series of experiments and their subsequent analysis in terms of a fluorescence fluctuation model with which the model parameters are quantified. Using the model, the expected signal-to-noise ratio is then computed. Equivalence classes between different experimental conditions that produce images with similar signal-to-noise ratios can then be established. The method may also be used to estimate the smallest signals that can reliably be observed with each setting. PMID:24776736

  6. Effect of Permeability of Tipping Paper on Cigarette Burning Temperature and the Property of Mainstream Smoke

    NASA Astrophysics Data System (ADS)

    Yao, Zhen-Yu; Shen, Yan; Huang, Hai-Qun; Xu, Ji-Cang

    2016-05-01

    Cigarette smoke analysis of tipping paper with different permeability was carried out. The infrared thermal imager was used to measure burning temperature of cigarette with different permeability tipping paper. The results indicated that with the increase of tipping paper permeability, Tar, CO and nicotine in cigarette mainstream were significantly linear decreased, puff count was increased. Tipping paper permeability had a great influence on cigarette burning temperature. With the increase of tipping paper permeability, the third puff burning temperature and the average peak temperature values were dropped obviously, but the changes of smoldering temperature were not obvious. In addition, smoldering average temperature was significantly lower than the third puff burning temperature and peak temperature.

  7. Recent developments of optical fiber chemical sensors at IROE

    NASA Astrophysics Data System (ADS)

    Baldini, Francesco

    2002-02-01

    An overview is given on the activity in progress at IROE, relative to the field of optical fibre sensors for chemical parameters. Optode-based sensors are under development for both biomedical and environmental applications. As for the biomedical field, particular attention will be devoted to clinical applications of the developed sensor in gastroenterology. The first clinical applications of an absorption-based sensor for the detection of gastric carbon dioxide will be described. Clinical results have shown the superiority of the developed sensor over the sensor currently available on the market and based on air tonometry. New clinical findings involving a sensor for the detection of bile will be also discussed. As far as environmental applications are concerned, an optode for the detection of nitrogen dioxide will be described.

  8. [A comparison of rebound tonometry (ICare) with TonoPenXL and Goldmann applanation tonometry].

    PubMed

    Schreiber, W; Vorwerk, C K; Langenbucher, A; Behrens-Baumann, W; Viestenz, A

    2007-04-01

    Goldmann applanation tonometry and dynamic contour tonometry (PASCAL) are two well established slit lamp mounted tonometric methods. Intraocular pressure measurement in bedridden patients and children is often only possible using hand held tonometers (TonoPenXL, Perkins tonometer, Draeger tonometer). This study was performed to evaluate the hand held ICare tonometer, which is based on the rebound method. A total of 102 eyes were examined by two highly experienced ophthalmologists for: 1) ophthalmological status, 2) central corneal power (Zeiss IOL-Master), 3) central corneal thickness (Tomey ultrasound pachymetry, five successive measurements, SD<5%), 4) intraocular pressure (IOP) measurement with the Goldmann applantation tonometer (GAT) 1x, 5) TonoPenXL (1x), 6) ICare with three successive measurement series of 6 single measurements. The mean IOP(GAT) was 13.2+/-3.0 mmHg compared with the mean IOP(TonoPenXL) (13.4+/-3.1 mmHg) and with the IOP(ICare) (mean value of first measurement series: 13.4+/-3.1 mmHg). The series of measurements with the ICare showed a tonography effect (decrease of IOP from 14.6 mmHg at the first measurement and 14.2 mmHg at the second to 14.0 at the third measurement). The ICare-measurements were highly reliable (Cronbach's alpha=0.974) and showed a good correlation between the measurement series (r=0.592-0.642; p<0.001). There was a great intra-individual variability of up to 17 mmHg between the GAT, TonoPenXL and ICare methods. The ICare tonometer is easy to handle and high reliability. The data are comparable with those from the Goldmann tonometer. A tonography effect of 0.6 mmHg in the successive measurement series was found.

  9. Nicotine and carbon monoxide exposure from inhalation of cigarillo smoke.

    PubMed

    Koszowski, Bartosz; Rosenberry, Zachary R; Kanu, Alieu; Viray, Lauren C; Potts, Jennifer L; Pickworth, Wallace B

    2015-12-01

    There has been an increase in the use of cigarillos in the US. People who smoke cigarillos typically also regularly smoke cigarettes (dual users). We compared puffing topography, biomarkers of acute exposure [exhaled carbon monoxide (COex) and plasma nicotine] and physiologic effects from usual brand cigarette and Black & Mild cigarillo smoking in dual users (N=23) in two laboratory sessions. Participants (21 men) smoked an average of 17.5cigarettes/day. Cigarillo consumption varied widely from as few as 1/week to daily. Participants were highly nicotine dependent (average FTND score: 6.3). There were statistically significant differences in smoking behavior between cigarette and cigarillo smoking in time to smoke, number of puffs, and total puff volume (all P<0.001). Average puff duration, interpuff interval average puff volume, and puff velocity did not differ between cigarettes and cigarillos. Nicotine boost was similar after both cigarettes and cigarillos. COex boost was significantly greater after cigarillo smoking compared to cigarette smoking (P<0.001). The smoking pattern and exposure profile indicate that dual users inhale cigarillo smoke just as they inhale cigarette smoke thereby exposing themselves to considerable amounts of nicotine and other components of tobacco smoke. COex exposure results imply that cigarillo smoking may be associated with higher exposure to smoke-delivered volatile components of mainstream cigarillo smoke including carcinogens when compared to cigarettes. The findings that cigarillos and cigarettes are smoked similarly in dual users are relevant to health and regulatory considerations on cigar products. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Evaluation of Savannah River Plant emergency response models using standard and nonstandard meteorological data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoel, D.D.

    1984-01-01

    Two computer codes have been developed for operational use in performing real time evaluations of atmospheric releases from the Savannah River Plant (SRP) in South Carolina. These codes, based on mathematical models, are part of the SRP WIND (Weather Information and Display) automated emergency response system. Accuracy of ground level concentrations from a Gaussian puff-plume model and a two-dimensional sequential puff model are being evaluated with data from a series of short range diffusion experiments using sulfur hexafluoride as a tracer. The models use meteorological data collected from 7 towers on SRP and at the 300 m WJBF-TV tower aboutmore » 15 km northwest of SRP. The winds and the stability, which is based on turbulence measurements, are measured at the 60 m stack heights. These results are compared to downwind concentrations using only standard meteorological data, i.e., adjusted 10 m winds and stability determined by the Pasquill-Turner stability classification method. Scattergrams and simple statistics were used for model evaluations. Results indicate predictions within accepted limits for the puff-plume code and a bias in the sequential puff model predictions using the meteorologist-adjusted nonstandard data. 5 references, 4 figures, 2 tables.« less

  11. Central corneal thickness in glaucoma.

    PubMed

    Sng, Chelvin C A; Ang, Marcus; Barton, Keith

    2017-03-01

    The purpose of this review is to summarize the role of central corneal thickness (CCT) in the clinical management of a glaucoma patient. The prognostic value of CCT is well recognized in patients with ocular hypertension. However, its predictive value in other glaucoma suspects and patients with established glaucoma is less certain. Tonometry artefacts can result from variations in CCT. However, an adequately validated correction algorithm for Goldmann applanation tonometry measurements does not exist. Newer methods of tonometry are potentially less influenced by CCT but are limited in their clinical use. There may also be biological and genetic associations between corneal thickness and glaucoma. Demographics, environmental factors, glaucoma treatment and the measurement device used have a significant influence on CCT, and should be considered when interpreting the effect of cornea thickness in patients with glaucoma. New measurements of the biomechanical properties of the cornea are likely to be better approximations of the globe biomechanics than CCT, but these require further evaluation. The clinical significance of CCT is well recognized in the context of glaucoma diagnosis and management, though the extent of its importance remains debatable. Corneal biomechanical properties may be more significantly associated with glaucoma than CCT.

  12. The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry.

    PubMed

    Zeri, Fabrizio; De Cusatis, Mario; Lupelli, Luigi; Swann, Peter Graham

    2016-01-01

    To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects' right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses. Copyright © 2016 The Authors. Published by Elsevier Espana.. All rights reserved.

  13. Design and initial results from a kilojoule level Dense Plasma Focus with hollow anode and cylindrically symmetric gas puff.

    PubMed

    Ellsworth, J L; Falabella, S; Tang, V; Schmidt, A; Guethlein, G; Hawkins, S; Rusnak, B

    2014-01-01

    We have designed and built a Dense Plasma Focus (DPF) Z-pinch device using a kJ-level capacitor bank and a hollow anode, and fueled by a cylindrically symmetric gas puff. Using this device, we have measured peak deuteron beam energies of up to 400 keV at 0.8 kJ capacitor bank energy and pinch lengths of ∼6 mm, indicating accelerating fields greater than 50 MV/m. Neutron yields of on the order of 10(7) per shot were measured during deuterium operation. The cylindrical gas puff system permitted simultaneous operation of DPF with a radiofrequency quadrupole accelerator for beam-into-plasma experiments. This paper describes the machine design, the diagnostic systems, and our first results.

  14. An Investigation of Fully Modulated, Turbulent Diffusion Flames in Reduced Gravity

    NASA Technical Reports Server (NTRS)

    Hermanson, J. C.; Johari, H.; Usowicz, J. E.; Sangras, R.; Stocker, D. P.; Hegde, U. G.; Nagashima, T.; Obata, S.

    2001-01-01

    Pulsed combustion appears to have the potential to provide for rapid fuel/air mixing, compact and economical combustors, and reduced exhaust emissions. The objective of this Flight-Definition experiment (PuFF, for Pulsed-Fully Flames) is to increase the fundamental understanding of the fuel/air mixing and combustion behavior of pulsed, turbulent diffusion flames by conducting experiments in microgravity. In this research the fuel jet is fully modulated (i.e., completely shut off between pulses) by an externally controlled valve system. This gives rise to drastic modification of the combustion and flow characteristics of flames, leading to enhanced fuel/air mixing mechanisms not operative for the case of acoustically excited or partially-modulated jets. The fully-modulated injection approach also simplifies the combustion process by avoiding the acoustic forcing generally present in pulsed combustors. Relatively little is known about the behavior of turbulent flames in reduced-gravity conditions, even in the absence of pulsing. Fundamental issues addressed in this experiment include the impact of buoyancy on the fuel/air mixing and combustion characteristics of fully-modulated flames. It is also important for the planned space experiments to establish the effects of confinement and oxidizer co-flow on these flames.

  15. Dynamic Radioactive Source for Evaluating and Demonstrating Time-dependent Performance of Continuous Air Monitors.

    PubMed

    McLean, Thomas D; Moore, Murray E; Justus, Alan L; Hudston, Jonathan A; Barbé, Benoît

    2016-11-01

    Evaluation of continuous air monitors in the presence of a plutonium aerosol is time intensive, expensive, and requires a specialized facility. The Radiation Protection Services Group at Los Alamos National Laboratory has designed a Dynamic Radioactive Source, intended to replace plutonium aerosol challenge testing. The Dynamic Radioactive Source is small enough to be inserted into the sampler filter chamber of a typical continuous air monitor. Time-dependent radioactivity is introduced from electroplated sources for real-time testing of a continuous air monitor where a mechanical wristwatch motor rotates a mask above an alpha-emitting electroplated disk source. The mask is attached to the watch's minute hand, and as it rotates, more of the underlying source is revealed. The measured alpha activity increases with time, simulating the arrival of airborne radioactive particulates at the air sampler inlet. The Dynamic Radioactive Source allows the temporal behavior of puff and chronic release conditions to be mimicked without the need for radioactive aerosols. The new system is configurable to different continuous air monitor designs and provides an in-house testing capability (benchtop compatible). It is a repeatable and reusable system and does not contaminate the tested air monitor. Test benefits include direct user control, realistic (plutonium) aerosol spectra, and iterative development of continuous air monitor alarm algorithms. Data obtained using the Dynamic Radioactive Source has been used to elucidate alarm algorithms and to compare the response time of two commercial continuous air monitors.

  16. Dynamic Radioactive Source for Evaluating and Demonstrating Time-dependent Performance of Continuous Air Monitors

    DOE PAGES

    McLean, Thomas D.; Moore, Murray E.; Justus, Alan L.; ...

    2016-01-01

    Evaluation of continuous air monitors in the presence of a plutonium aerosol is time intensive, expensive, and requires a specialized facility. The Radiation Protection Services Group at Los Alamos National Laboratory has designed a Dynamic Radioactive Source, intended to replace plutonium aerosol challenge testing. Furthermore, the Dynamic Radioactive Source is small enough to be inserted into the sampler filter chamber of a typical continuous air monitor. Time-dependent radioactivity is introduced from electroplated sources for real-time testing of a continuous air monitor where a mechanical wristwatch motor rotates a mask above an alpha-emitting electroplated disk source. The mask is attached tomore » the watch’s minute hand, and as it rotates, more of the underlying source is revealed. The alpha activity we measured increases with time, simulating the arrival of airborne radioactive particulates at the air sampler inlet. The Dynamic Radioactive Source allows the temporal behavior of puff and chronic release conditions to be mimicked without the need for radioactive aerosols. The new system is configurable to different continuous air monitor designs and provides an in-house testing capability (benchtop compatible). It is a repeatable and reusable system and does not contaminate the tested air monitor. Test benefits include direct user control, realistic (plutonium) aerosol spectra, and iterative development of continuous air monitor alarm algorithms. We also used data obtained using the Dynamic Radioactive Source to elucidate alarm algorithms and to compare the response time of two commercial continuous air monitors.« less

  17. Buoyancy Effects in Fully-Modulated, Turbulent Diffusion Flames

    NASA Technical Reports Server (NTRS)

    Hermanson, J. C.; Johari, H.; Ghaem-Maghami, E.; Stocker, D. P.; Hegde, U. G.; Page, K. L.

    2003-01-01

    Pulsed combustion appears to have the potential to provide for rapid fuel/air mixing, compact and economical combustors, and reduced exhaust emissions. The objective of this experiment (PuFF, for Pulsed-Fully Flames) is to increase the fundamental understanding of the fuel/air mixing and combustion behavior of pulsed, turbulent diffusion flames by conducting experiments in microgravity. In this research the fuel jet is fully-modulated (i.e., completely shut off between pulses) by an externally controlled valve system. This gives rise to drastic modification of the combustion and flow characteristics of flames, leading to enhanced fuel/air mixing compared to acoustically excited or partially-modulated jets. Normal-gravity experiments suggest that the fully-modulated technique also has the potential for producing turbulent jet flames significantly more compact than steady flames with no increase in exhaust emissions. The technique also simplifies the combustion process by avoiding the acoustic forcing generally present in pulsed combustors. Fundamental issues addressed in this experiment include the impact of buoyancy on the structure and flame length, temperatures, radiation, and emissions of fully-modulated flames.

  18. Enhanced air dispersion modelling at a typical Chinese nuclear power plant site: Coupling RIMPUFF with two advanced diagnostic wind models.

    PubMed

    Liu, Yun; Li, Hong; Sun, Sida; Fang, Sheng

    2017-09-01

    An enhanced air dispersion modelling scheme is proposed to cope with the building layout and complex terrain of a typical Chinese nuclear power plant (NPP) site. In this modelling, the California Meteorological Model (CALMET) and the Stationary Wind Fit and Turbulence (SWIFT) are coupled with the Risø Mesoscale PUFF model (RIMPUFF) for refined wind field calculation. The near-field diffusion coefficient correction scheme of the Atmospheric Relative Concentrations in the Building Wakes Computer Code (ARCON96) is adopted to characterize dispersion in building arrays. The proposed method is evaluated by a wind tunnel experiment that replicates the typical Chinese NPP site. For both wind speed/direction and air concentration, the enhanced modelling predictions agree well with the observations. The fraction of the predictions within a factor of 2 and 5 of observations exceeds 55% and 82% respectively in the building area and the complex terrain area. This demonstrates the feasibility of the new enhanced modelling for typical Chinese NPP sites. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Smoking Topography Characteristics of Very Low Nicotine Content Cigarettes, With and Without Nicotine Replacement, in Smokers With Schizophrenia and Controls

    PubMed Central

    Cassidy, Rachel N.; Miller, Mollie E.

    2016-01-01

    Introduction: Reducing the nicotine content of cigarettes to a minimally addictive level has been proposed as a regulatory strategy for reducing tobacco dependence. However, smokers with schizophrenia (SS) may be prone to changing their smoking topography in efforts to compensate for the reduction in nicotine content. The aims of this study were to compare smoking topography characteristics of usual-brand and very low nicotine content (VLNC) cigarettes in SS and control smokers without psychiatric illness (CS), and to determine whether nicotine replacement reversed any changes in topography produced by VLNC cigarettes. Methods: Using a within-subjects, counter-balanced design, SS (n = 27) and CS (n = 23) smoked usual brand cigarettes, VLNC cigarettes while wearing placebo patches (VLNC + PLA), or VLNC cigarettes while wearing transdermal nicotine patches totaling 42mg (VLNC + NIC) during 5-hour ad libitum smoking sessions. Cigarettes were smoked through topography measurement devices. Results: Across conditions, SS smoked more puffs per session and per cigarette, had higher cigarette volumes, and had shorter inter-puff intervals than CS (Ps < .01). During VLNC cigarette sessions, puff duration increased and time between puffs decreased, but participants smoked fewer puffs, resulting in a net decrease in cigarette and total session volume (Ps < .001). There were no significant interactions between group and condition. Conclusions: These findings indicate that acute use of VLNC cigarettes does not increase intensity of smoking in SS, and support the feasibility of a nicotine reduction policy. Implications: Reducing the nicotine in cigarettes to a minimally addictive level has been proposed as a means of reducing tobacco dependence. However, smokers, particularly those with schizophrenia (SS) may alter their puffing in an attempt to extract more nicotine from VLNC cigarettes. This study compared smoking topography of usual brand versus VLNC cigarettes, combined with placebo or transdermal nicotine patches, in SS and controls. Although some changes in topography were indicative of compensatory smoking, total puffs and total cigarette volume were reduced with VLNC cigarettes, indicating that acute VLNC cigarette use does not increase smoking in SS. PMID:26995794

  20. Characterisation of the borgwaldt LM4E system for in vitro exposures to undiluted aerosols from next generation tobacco and nicotine products (NGPs).

    PubMed

    Adamson, Jason; Jaunky, Tomasz; Thorne, David; Gaça, Marianna D

    2018-03-01

    Traditional in vitro exposure to combustible tobacco products utilise exposure systems that include the use of smoking machines to generate, dilute and deliver smoke to in vitro cell cultures. With reported lower emissions from next generation tobacco and nicotine products (NGPs), including e-cigarettes and tobacco heating products (THPs), diluting the aerosol is potentially not required. Herein we present a simplified exposure scenario to undiluted NGP aerosols, using a new puffing system called the LM4E. Nicotine delivery from an e-cigarette was used as a dosimetry marker, and was measured at source across 4 LM4E ports and in the exposure chamber. Cell viability studies, using Neutral Red Uptake (NRU) assay, were performed using H292 human lung epithelial cells, testing undiluted aerosols from an e-cigarette and a THP. E-cigarette mean nicotine generated at source was measured at 0.084 ± 0.005 mg/puff with no significant differences in delivery across the 4 different ports, p = 0.268 (n = 10/port). Mean nicotine delivery from the e-cigarette to the in vitro exposure chamber (measured up to 100 puffs) was 0.046 ± 0.006 mg/puff, p = 0.061. Aerosol penetration within the LM4E was 55% from source to chamber. H292 cells were exposed to undiluted e-cigarette aerosol for 2 h (240 puffs) or undiluted THP aerosol for 1 h (120 puffs). There were positive correlations between puff number and nicotine in the exposed culture media, R 2  = 0.764 for the e-cigarette and R 2  = 0.970 for the THP. NRU determined cell viability for e-cigarettes after 2 h' exposure resulted in 21.5 ± 17.0% cell survival, however for the THP, full cytotoxicity was reached after 1-h exposure. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Disposable Electronic Cigarettes and Electronic Hookahs: Evaluation of Performance

    PubMed Central

    Williams, Monique; Ghai, Sanjay

    2015-01-01

    Introduction: The purpose of this study was to characterize the performance of disposable button-activated and disposable airflow-activated electronic cigarettes (EC) and electronic hookahs (EH). Methods: The airflow rate required to produce aerosol, pressure drop, and the aerosol absorbance at 420nm were measured during smoke-outs of 9 disposable products. Three units of each product were tested in these experiments. Results: The airflow rates required to produce aerosol and the aerosol absorbances were lower for button-activated models (3mL/s; 0.41–0.55 absorbance) than for airflow-activated models (7–17mL/s; 0.48–0.84 absorbance). Pressure drop was also lower across button-activated products (range = 6–12mm H2O) than airflow-activated products (range = 15–67mm H20). For 25 of 27 units tested, airflow did not have to be increased during smoke-out to maintain aerosol production, unlike earlier generation models. Two brands had uniform performance characteristics for all parameters, while 3 had at least 1 product that did not function normally. While button-activated models lasted 200 puffs or less and EH airflow-activated models often lasted 400 puffs, none of the models produced as many puffs as advertised. Puff number was limited by battery life, which was shorter in button-activated models. Conclusion: The performance of disposable products was differentiated mainly by the way the aerosol was produced (button vs airflow-activated) rather than by product type (EC vs EH). Users needed to take harder drags on airflow-activated models. Performance varied within models, and battery life limited the number of puffs. Data suggest quality control in manufacturing varies among brands. PMID:25104117

  2. Efficient generation of fast neutrons by magnetized deuterons in an optimized deuterium gas-puff z-pinch

    NASA Astrophysics Data System (ADS)

    Klir, D.; Shishlov, A. V.; Kokshenev, V. A.; Kubes, P.; Labetsky, A. Yu; Rezac, K.; Cherdizov, R. K.; Cikhardt, J.; Cikhardtova, B.; Dudkin, G. N.; Fursov, F. I.; Garapatsky, A. A.; Kovalchuk, B. M.; Kravarik, J.; Kurmaev, N. E.; Orcikova, H.; Padalko, V. N.; Ratakhin, N. A.; Sila, O.; Turek, K.; Varlachev, V. A.

    2015-04-01

    Z-pinch experiments with deuterium gas puffs have been carried out on the GIT-12 generator at 3 MA currents. Recently, a novel configuration of a deuterium gas-puff z-pinch was used to accelerate deuterons and to generate fast neutrons. In order to form a homogeneous, uniformly conducting layer at a large initial radius, an inner deuterium gas puff was surrounded by an outer hollow cylindrical plasma shell. The plasma shell consisting of hydrogen and carbon ions was formed at the diameter of 350 mm by 48 plasma guns. A linear mass of the plasma shell was about 5 µg cm-1 whereas a total linear mass of deuterium gas in single or double shell gas puffs was about 100 µg cm-1. The implosion lasted 700 ns and seemed to be stable up to a 5 mm radius. During stagnation, m = 0 instabilities became more pronounced. When a disruption of necks occurred, the plasma impedance reached 0.4 Ω and high energy (>2 MeV) bremsstrahlung radiation together with high energy deuterons were produced. Maximum neutron energies of 33 MeV were observed by axial time-of-flight detectors. The observed neutron spectra could be explained by a suprathermal distribution of deuterons with a high energy tail f≤ft({{E}\\text{d}}\\right)\\propto E\\text{d}-(1.8+/- 0.2) . Neutron yields reached 3.6 × 1012 at a 2.7 MA current. A high neutron production efficiency of 6 × 107 neutrons per one joule of plasma energy resulted from the generation of high energy deuterons and from their magnetization inside plasmas.

  3. Aldehyde levels in e-cigarette aerosol: Findings from a replication study and from use of a new-generation device.

    PubMed

    Farsalinos, Konstantinos E; Kistler, Kurt A; Pennington, Alexander; Spyrou, Alketa; Kouretas, Dimitris; Gillman, Gene

    2018-01-01

    A recent study identified high aldehyde emissions from e-cigarettes (ECs), that when converted to reasonable daily human EC liquid consumption, 5 g/day, gave formaldehyde exposure equivalent to 604-3257 tobacco cigarettes. We replicated this study and also tested a new-generation atomizer under verified realistic (no dry puff) conditions. CE4v2 atomizers were tested at 3.8 V and 4.8 V, and a Nautilus Mini atomizer was tested at 9.0 W and 13.5 W. All measurements were performed in a laboratory ISO-accredited for EC aerosol collection and aldehyde measurements. CE4v2 generated dry puffs at both voltage settings. Formaldehyde levels were >10-fold lower, acetaldehyde 6-9-fold lower and acrolein 16-26-fold lower than reported in the previous study. Nautilus Mini did not generate dry puffs, and minimal aldehydes were emitted despite >100% higher aerosol production per puff compared to CE4v2 (formaldehyde: 16.7 and 16.5 μg/g; acetaldehyde: 9.6 and 10.3 μg/g; acrolein: 8.6 and 11.7 μg/g at 9.0 W and 13.5 W, respectively). EC liquid consumption of 5 g/day reduces aldehyde exposure by 94.4-99.8% compared to smoking 20 tobacco cigarettes. Checking for dry puffs is essential for EC emission testing. Under realistic conditions, new-generation ECs emit minimal aldehydes/g liquid at both low and high power. Validated methods should be used when analyzing EC aerosol. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Characterization of neutron emission from mega-ampere deuterium gas puff Z-pinch at microsecond implosion times

    NASA Astrophysics Data System (ADS)

    Klir, D.; Shishlov, A. V.; Kokshenev, V. A.; Kubes, P.; Labetsky, A. Yu; Rezac, K.; Cikhardt, J.; Fursov, F. I.; Kovalchuk, B. M.; Kravarik, J.; Kurmaev, N. E.; Ratakhin, N. A.; Sila, O.; Stodulka, J.

    2013-08-01

    Experiments with deuterium (D2) triple shell gas puffs were carried out on the GIT-12 generator at a 3 MA current level and microsecond implosion times. The outer, middle and inner nozzle diameters were 160 mm, 80 mm and 30 mm, respectively. The influence of the mass of deuterium shells on neutron emission times, neutron yields and neutron energy spectra was studied. The injected linear mass of deuterium varied between 50 and 255 µg cm-1. Gas puffs imploded onto the axis before the peak of generator current at 700-1100 ns. Most of the neutrons were emitted during the second neutron pulse after the development of instabilities. Despite higher currents, heavier gas puffs produced lower neutron yields. Optimal mass and a short time delay between the valve opening and the generator triggering were more important than the better coincidence of stagnation with peak current. The peak neutron yield from D(d, n)3He reactions reached 3 × 1011 at 2.8 MA current, 90 µg cm-1 injected linear mass and 37 mm anode-cathode gap. In the case of lower mass shots, a large number of 10 MeV neutrons were produced either by secondary DT reactions or by DD reactions of deuterons with energies above 7 MeV. The average neutron yield ratio Y>10 MeV/Y2.5 MeV reached (6 ± 3) × 10-4. Such a result can be explained by a power law distribution for deuterons as \\rmd N_d/\\rmd E_d\\propto E_d^{-3} . The optimization of a D2 gas puff Z-pinch and similarities to a plasma focus and its drive parameter are described.

  5. Wide band laser-plasma soft X-ray source using a gas puff target for direct photo-etching of polymers

    NASA Astrophysics Data System (ADS)

    Bartnik, Andrzej; Fiedorowicz, Henryk; Jarocki, Roman; Kostecki, Jerzy; Rakowski, Rafał; Szczurek, Mirosław

    2005-09-01

    Organic polymers (PMMA, PTFE, PET, and PI) are considered as the important materials in microengineering, especially for biological and medical applications. Micromachining of such materials is possible with the use of different techniques that involve electromagnetic radiation or charged particle beams. Another possibility of high aspect ratio micromachining of PTFE is direct photo-etching using synchrotron radiation. X-ray and ultraviolet radiation from other sources, for micromachining of materials by direct photo-etching can be also applied. In this paper we present the results of investigation of a wide band soft X-ray source and its application for direct photo-etching of organic polymers. X-ray radiation in the wavelength range from about 3 nm to 20 nm was produced as a result of irradiation of a double-stream gas puff target with laser pulses of energy 0.8 J and time duration of about 3 ns. The spectra, plasma size and absolute energies of soft X-ray pulses for different gas puff targets were measured. Photo-etching process of polymers irradiated with the use of the soft X-ray radiation was analyzed and investigated. Samples of organic polymers were placed inside a vacuum chamber of the x-ray source, close to the gas puff target at the distance of about 2 cm from plasmas created by focused laser pulses. A fine metal grid placed in front of the samples was used as a mask to form structures by x-ray ablation. The results of photo-etching process for several minutes exposition with l0Hz repetition rate were presented. High ablation efficiency was obtained with the use of the gas puff target containing xenon surrounded by helium.

  6. Relationship between negative affect and smoking topography in heavy drinking smokers.

    PubMed

    Green, ReJoyce; Bujarski, Spencer; Roche, Daniel J O; Ray, Lara A

    2016-10-01

    Heavy drinking smokers represent a sizeable subgroup of smokers for whom nicotine deprivation and alcohol use increases the urge to smoke in the laboratory and predicts lapses during smoking cessation. The manner in which individuals smoke a cigarette (i.e. smoking topography) provides a reliable index of smoking intensity and reinforcement, yet the effects of affect on smoking topography have not been thoroughly examined in heavy drinking smokers. The current study examined how affect and nicotine deprivation predict smoking behavior as participants (N=27) smoked one cigarette using a smoking topography device after 12-h of nicotine abstinence and after a priming dose of alcohol (target BrAC=0.06g/dl). Primary smoking topography measures were puff volume, velocity, duration, and inter-puff interval (IPI). The effect of nicotine deprivation was measured by the Minnesota Nicotine Withdrawal Scale (MNWS) and the Profile of Mood States (POMS). Measures were obtained at baseline (i.e. 12-h of nicotine abstinence and pre-alcohol) and 30-minutes after alcohol administration (i.e. peak BrAC). Results revealed post-priming negative affect significantly moderated the trajectories of puff volume, puff duration and IPI (p's<0.05) over the course of the cigarette, such that those with greater negative affect had flatter slopes for volume and duration and increasingly infrequent puffs. Our results suggest that baseline and post-priming negative affect following nicotine deprivation alters smoking patterns and increases nicotine exposure throughout a single cigarette. Future studies need to examine differential amounts of nicotine deprivation on response to alcohol and smoking in heavy drinking smokers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. The Pulsed Fission-Fusion (PUFF) Concept for Deep Space Exploration and Terrestrial Power Generation

    NASA Technical Reports Server (NTRS)

    Adams, Robert; Cassibry, Jason; Schillo, Kevin

    2017-01-01

    This team is exploring a modified Z-pinch geometry as a propulsion system, imploding a liner of liquid lithium onto a pellet containing both fission and fusion fuel. The plasma resulting from the fission and fusion burn expands against a magnetic nozzle, for propulsion, or a magnetic confinement system, for terrestrial power generation. There is considerable synergy in the concept; the lithium acts as a temporary virtual cathode, and adds reaction mass for propulsion. Further, the lithium acts as a radiation shield against generated neutrons and gamma rays. Finally, the density profile of the column can be tailored using the lithium sheath. Recent theoretical and experimental developments (e.g. tailored density profile in the fuel injection, shear stabilization, and magnetic shear stabilization) have had great success in mitigating instabilities that have plagued previous fusion efforts. This paper will review the work in evaluating the pellet sizes and z-pinch conditions for optimal PuFF propulsion. Trades of pellet size and composition with z-pinch power levels and conditions for the tamper and lithium implosion are evaluated. Current models, both theoretical and computational, show that a z-pinch can ignite a small (1 cm radius) fission-fusion target with significant yield. Comparison is made between pure fission and boosted fission targets. Performance is shown for crewed spacecraft for high speed Mars round trip missions and near interstellar robotic missions. The PuFF concept also offers a solution for terrestrial power production. PuFF can, with recycling of the effluent, achieve near 100% burnup of fission fuel, providing a very attractive power source with minimal waste. The small size of PuFF relative to today's plants enables a more distributed power network and less exposure to natural or man-made disruptions.

  8. The Impact of Multipollutant Clusters on the Association Between Fine Particulate Air Pollution and Microvascular Function.

    PubMed

    Ljungman, Petter L; Wilker, Elissa H; Rice, Mary B; Austin, Elena; Schwartz, Joel; Gold, Diane R; Koutrakis, Petros; Benjamin, Emelia J; Vita, Joseph A; Mitchell, Gary F; Vasan, Ramachandran S; Hamburg, Naomi M; Mittleman, Murray A

    2016-03-01

    Prior studies including the Framingham Heart Study have suggested associations between single components of air pollution and vascular function; however, underlying mixtures of air pollution may have distinct associations with vascular function. We used a k-means approach to construct five distinct pollution mixtures from elemental analyses of particle filters, air pollution monitoring data, and meteorology. Exposure was modeled as an interaction between fine particle mass (PM2.5), and concurrent pollution cluster. Outcome variables were two measures of microvascular function in the fingertip in the Framingham Offspring and Third Generation cohorts from 2003 to 2008. In 1,720 participants, associations between PM2.5 and baseline pulse amplitude tonometry differed by air pollution cluster (interaction P value 0.009). Higher PM2.5 on days with low mass concentrations but high proportion of ultrafine particles from traffic was associated with 18% (95% confidence interval: 4.6%, 33%) higher baseline pulse amplitude per 5 μg/m and days with high contributions of oil and wood combustion with 16% (95% confidence interval: 0.2%, 34%) higher baseline pulse amplitude. We observed no variation in associations of PM2.5 with hyperemic response to ischemia observed across air pollution clusters. PM2.5 exposure from air pollution mixtures with large contributions of local ultrafine particles from traffic, heating oil, and wood combustion was associated with higher baseline pulse amplitude but not hyperemic response. Our findings suggest little association between acute exposure to air pollution clusters reflective of select sources and hyperemic response to ischemia, but possible associations with excessive small artery pulsatility with potentially deleterious microvascular consequences.

  9. The Impact of Multi-pollutant Clusters on the Association between Fine Particulate Air Pollution and Microvascular Function

    PubMed Central

    Ljungman, Petter L.; Wilker, Elissa H.; Rice, Mary B.; Austin, Elena; Schwartz, Joel; Gold, Diane R.; Koutrakis, Petros; Benjamin, Emelia J.; Vita, Joseph A.; Mitchell, Gary F.; Vasan, Ramachandran S.

    2016-01-01

    Background Prior studies including the Framingham Heart Study have suggested associations between single components of air pollution and vascular function; however, underlying mixtures of air pollution may have distinct associations with vascular function. Methods We used a k-means approach to construct five distinct pollution mixtures from elemental analyses of particle filters, air pollution monitoring data, and meteorology. Exposure was modeled as an interaction between fine particle mass (PM2.5), and concurrent pollution cluster. Outcome variables were two measures of microvascular function in the fingertip in the Framingham Offspring and Third Generation cohorts from 2003-2008. Results In 1,720 participants, associations between PM2.5 and baseline pulse amplitude tonometry differed by air pollution cluster (interaction p value 0.009). Higher PM2.5 on days with low mass concentrations but high proportion of ultrafine particles from traffic was associated with 18% (95% CI 4.6%; 33%) higher baseline pulse amplitude per 5 μg/m3 and days with high contributions of oil and wood combustion with 16% (95% CI 0.2%; 34%) higher baseline pulse amplitude. We observed no variation in associations of PM2.5 with hyperemic response to ischemia observed across air pollution clusters. Conclusions PM2.5 exposure from air pollution mixtures with large contributions of local ultrafine particles from traffic, heating oil and wood combustion was associated with higher baseline pulse amplitude but not PAT ratio. Our findings suggest little association between acute exposure to air pollution clusters reflective of select sources and hyperemic response to ischemia, but possible associations with excessive small artery pulsatility with potentially deleterious microvascular consequences. PMID:26562062

  10. Umbral oscillations and penumbral waves in H alpha. [in sunspots

    NASA Technical Reports Server (NTRS)

    Moore, R. L.; Tang, F.

    1975-01-01

    Examples are presented of umbral oscillations observed on Big Bear H-alpha filtergram movies, and the relation between umbral oscillations and running penumbral waves occurring in the same sunspot is investigated. Umbral oscillations near the center of the umbra are probably physically independent of the penumbral waves because the period of these umbral oscillations (150 sec) is shorter than the penumbral wave period (270 sec), but not a harmonic. Dark puffs emerge from the edge of the umbra and move outward across the penumbra, and have the same period as the running penumbral waves. These dark puffs are interpreted to be the extension of chromospheric umbral oscillations at the edge of the umbra. It is suggested that the dark puffs and the running penumbral waves have a common source: photospheric oscillations just inside the umbra.

  11. Demonstration of a neonlike argon soft-x-ray laser with a picosecond-laser-irradiated gas puff target.

    PubMed

    Fiedorowicz, H; Bartnik, A; Dunn, J; Smith, R F; Hunter, J; Nilsen, J; Osterheld, A L; Shlyaptsev, V N

    2001-09-15

    We demonstrate a neonlike argon-ion x-ray laser, using a short-pulse laser-irradiated gas puff target. The gas puff target was formed by pulsed injection of gas from a high-pressure solenoid valve through a nozzle in the form of a narrow slit and irradiated with a combination of long, 600-ps and short, 6-ps high-power laser pulses with a total of 10 J of energy in a traveling-wave excitation scheme. Lasing was observed on the 3p (1)S(0)?3s (1)P(1) transition at 46.9 nm and the 3d (1)P(1)?3p (1)P(1) transition at 45.1 nm. A gain of 11 cm(-1) was measured on these transitions for targets up to 0.9 cm long.

  12. Hedonic Predictors of Tobacco Dependence: A Puff Guide to Smoking Cessation

    DTIC Science & Technology

    2015-04-07

    process may not always be the case. While Perkins et al. (31) showed the potential for a connection between puff volume, considered reinforcement...effect can be attributed to the effects of "acute tolerance" (31 ). Nicotine is thought to acutely desensitize nicotinic receptors ("acute tolerance...company that performs biological assays) for the cotinine assay. Salivary cotinine levels were measured through an enzyme immunoassay conducted by

  13. Marihuana-induced embryotoxicity in the rabbit.

    PubMed

    Rosenkrantz, H; Grant, R J; Fleischman, R W; Baker, J R

    1986-08-01

    Few teratogenic studies in animals have been performed simulating marihuana smoking in man. An inhalation marihuana teratology study was conducted in albino rabbits utilizing a modified automatic smoking machine originally developed for rats and mice. Appropriate numbers of dams were exposed to 4 puffs (0.14 mg/kg), 8 puffs (0.72 mg/kg), or 16 puffs (1.44 mg/kg) once daily during gestation Days 6 to 18, and sacrificed on Day 28. Control dams were exposed to 12 puffs of placebo cigarettes or sham-treated for a similar duration in the absence of any smoke. Consistency of smoke was monitored by cigarette weights, total particulate matter, concentrations of carbon monoxide (CO), and tetrahydrocannibinol (THC) in smoke, carboxyhemoglobin levels, and plasma THC levels. Except for a transient decrease in dam respiration rates, other gross toxic signs were absent. Reproductive parameters of mothers were generally normal except for a dose-related embryotoxicity predominantly associated with early resorptions. Despite twice the number of embryo/fetal deaths, there were no marihuana soft tissue or skeletal defects. A correlation between dam demises and CO levels among placebo-exposed animals was related to greater quantities of CO being generated during placebo combustion. It has been shown in the rabbit that marihuana is embryotoxic and not a teratogen at plasma THC levels found in human females.

  14. Acceptability and characterization of extruded pinto, navy and black beans.

    PubMed

    Simons, Courtney W; Hall, Clifford; Tulbek, Mehmet; Mendis, Mihiri; Heck, Taylor; Ogunyemi, Samuel

    2015-08-30

    Consumption of dry beans has been relatively flat over the last decade. Creating new bean products may increase the consumption of beans and allow more consumers to obtain the health benefits of beans. In this study, pinto, navy and black beans were milled and the resulting flours extruded into puffs. Unflavored extruded puffs were evaluated by untrained panelists using a hedonic scale for appearance, flavor, texture and overall acceptability. The compositions of raw flours and extrudates were characterized. Sensory results indicated that all beans met or exceeded the minimum requirement for acceptability. Overall acceptability of navy and pinto beans was not significantly different, while acceptability of black bean puffs was significantly lower. Total protein (198-217 g kg(-1)) in extrudates was significantly different among the three beans. Total starch ranged from 398 to 406 g kg(-1) and was not significantly different. Resistant starch, total extractable lipid and raffinose contents were significantly reduced by extrusion. Extrusion did not affect crude fiber and phytic acid contents. The minimal effects on protein and fiber contents, the significant reduction in raffinose content and the acceptability of the unflavored extruded puffs support using various bean flours as ingredients in extruded puffed products. © 2014 Society of Chemical Industry.

  15. Gorilla Mothers Also Matter! New Insights on Social Transmission in Gorillas (Gorilla gorilla gorilla) in Captivity

    PubMed Central

    Luef, Eva Maria; Pika, Simone

    2013-01-01

    The present paper describes two distinct behaviors relating to food processing and communication that were observed in a community of five separately housed groups of lowland gorillas (Gorilla gorilla gorilla) in captivity during two study periods one decade apart: (1) a food processing technique to separate wheat from chaff, the so-called puff-blowing technique; and (2) a male display used to attract the attention of visitors, the so-called throw-kiss-display. We investigated (a) whether the behaviors were transmitted within the respective groups; and if yes, (b) their possible mode of transmission. Our results showed that only the food processing technique spread from three to twenty-one individuals during the ten-year period, whereas the communicative display died out completely. The main transmission mode of the puff-blowing technique was the mother-offspring dyad: offspring of puff-blowing mothers showed the behavior, while the offspring of non- puff-blowing mothers did not. These results strongly support the role mothers play in the acquisition of novel skills and vertical social transmission. Furthermore, they suggest that behaviors, which provide a direct benefit to individuals, have a high chance of social transmission while the loss of benefits can result in the extinction of behaviors. PMID:24312184

  16. Gorilla mothers also matter! New insights on social transmission in gorillas (Gorilla gorilla gorilla) in captivity.

    PubMed

    Luef, Eva Maria; Pika, Simone

    2013-01-01

    The present paper describes two distinct behaviors relating to food processing and communication that were observed in a community of five separately housed groups of lowland gorillas (Gorilla gorilla gorilla) in captivity during two study periods one decade apart: (1) a food processing technique to separate wheat from chaff, the so-called puff-blowing technique; and (2) a male display used to attract the attention of visitors, the so-called throw-kiss-display. We investigated (a) whether the behaviors were transmitted within the respective groups; and if yes, (b) their possible mode of transmission. Our results showed that only the food processing technique spread from three to twenty-one individuals during the ten-year period, whereas the communicative display died out completely. The main transmission mode of the puff-blowing technique was the mother-offspring dyad: offspring of puff-blowing mothers showed the behavior, while the offspring of non- puff-blowing mothers did not. These results strongly support the role mothers play in the acquisition of novel skills and vertical social transmission. Furthermore, they suggest that behaviors, which provide a direct benefit to individuals, have a high chance of social transmission while the loss of benefits can result in the extinction of behaviors.

  17. Elements including metals in the atomizer and aerosol of disposable electronic cigarettes and electronic hookahs

    PubMed Central

    Williams, Monique; Bozhilov, Krassimir; Ghai, Sanjay; Talbot, Prue

    2017-01-01

    Objective Our purpose was to quantify 36 inorganic chemical elements in aerosols from disposable electronic cigarettes (ECs) and electronic hookahs (EHs), examine the effect of puffing topography on elements in aerosols, and identify the source of the elements. Methods Thirty-six inorganic chemical elements and their concentrations in EC/EH aerosols were determined using inductively coupled plasma optical emission spectroscopy, and their source was identified by analyzing disassembled atomizers using scanning electron microscopy and energy dispersive X-ray spectroscopy. Results Of 36 elements screened, 35 were detected in EC/EH aerosols, while only 15 were detected in conventional tobacco smoke. Some elements/metals were present in significantly higher concentrations in EC/EH aerosol than in cigarette smoke. Concentrations of particular elements/metals within EC/EH brands were sometimes variable. Aerosols generated at low and high air-flow rates produced the same pattern of elements, although the total element concentration decreased at the higher air flow rate. The relative amount of elements in the first and last 60 puffs was generally different. Silicon was the dominant element in aerosols from all EC/EH brands and in cigarette smoke. The elements appeared to come from the filament (nickel, chromium), thick wire (copper coated with silver), brass clamp (copper, zinc), solder joints (tin, lead), and wick and sheath (silicon, oxygen, calcium, magnesium, aluminum). Lead was identified in the solder and aerosol of two brands of EHs (up to 0.165 μg/10 puffs). Conclusion These data show that EC/EH aerosols contain a mixture of elements, including heavy metals, with concentrations often significantly higher than in conventional cigarette smoke. While the health effects of inhaling mixtures of heated metals is currently not known, these data will be valuable in future risk assessments involving EC/EH elements/metals. PMID:28414730

  18. Comparison of Ocular Pulse Amplitude Lowering Effects of Preservative-Free Tafluprost and Preservative-Free Dorzolamide-Timolol Fixed Combination Eyedrops.

    PubMed

    Seo, Du Ri; Ha, Seung Joo

    2015-01-01

    To compare the ocular pulse amplitude (OPA) lowering effects of preservative-free tafluprost and dorzolamide-timolol fixed combination (DTFC) using dynamic contour tonometry. In total, 66 eyes of 66 patients with normal tension glaucoma (NTG) (n = 34) or primary open angle glaucoma (POAG) (n = 32) were included. Patients were divided into two groups: the preservative-free tafluprost-treated group (n = 33) and the preservative-free DTFC-treated group (n = 33). Intraocular pressure (IOP) was measured using Goldmann applanation tonometry (GAT). OPA was measured using dynamic contour tonometry; corrected OPA (cOPA) was calculated at baseline and at 1 week and 1, 3, and 6 months after treatment. After 6 months of treatment, tafluprost significantly reduced IOP (P < 0.001). The OPA lowering effects differed significantly between the two treatment groups (P = 0.003). The cOPA-lowering effect of tafluprost (1.09 mmHg) was significantly greater than that of DTFC (0.36 mmHg) after 6 months of treatment (P = 0.01). Tafluprost and DTFC glaucoma treatments provided marked OPA and IOP lowering effects. Tafluprost had a greater effect than DTFC; thus, this drug is recommended for patients at risk of glaucoma progression, due to the high OPA caused by large fluctuations in IOP.

  19. Sleep-Disordered Breathing and Cardiovascular Correlates in College Football Players.

    PubMed

    Kim, Jonathan H; Hollowed, Casey; Irwin-Weyant, Morgan; Patel, Keyur; Hosny, Kareem; Aida, Hiroshi; Gowani, Zaina; Sher, Salman; Gleason, Patrick; Shoop, James L; Galante, Angelo; Clark, Craig; Ko, Yi-An; Quyyumi, Arshed A; Collop, Nancy A; Baggish, Aaron L

    2017-10-15

    This study sought to determine the cardiovascular physiologic correlates of sleep-disordered breathing (SDB) in American-style football (ASF) participants using echocardiography, vascular applanation tonometry, and peripheral arterial tonometry. Forty collegiate ASF participants were analyzed at pre- and postseason time points with echocardiography and vascular applanation tonometry. WatchPAT (inclusive of peripheral arterial tonometry) used to assess for SDB was then performed at the postseason time point. Twenty-two of 40 (55%) ASF participants demonstrated SDB with an apnea-hypopnea index (pAHI) ≥5. ASF participants with SDB were larger (109 ± 20 vs 92 ± 14 kg, p = 0.004) and more likely linemen position players (83% vs 50%, p = 0.03). Compared with those without SDB, ASF participants with SDB demonstrated relative impairments in left ventricular diastolic and vascular function as reflected by lower lateral e' (14 ± 3 vs 17 ± 3 cm/s, p = 0.007) and septal e' (11 ± 2 vs 13 ± 2 cm/s, p = 0.009) tissue velocities and higher pulse wave velocity (5.4 ± 0.9 vs 4.8 ± 0.5 m/s, p = 0.02). In the total cohort, there were significant positive correlations between pAHI and pulse wave velocity (r = 0.42, p = 0.008) and inverse correlations between pAHI and the averaged e' tissue velocities (r = -0.42, p = 0.01). In conclusion, SDB is highly prevalent in youthful collegiate ASF participants and associated with relative impairments in cardiac and vascular function. Targeted efforts to identify youthful populations with SDB, including ASF participants, and implement SDB treatment algorithms, represent important future clinical directives. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Ocular findings and reference values for selected ophthalmic diagnostic tests in the macaroni penguin (Eudyptes chrysolophus) and southern rockhopper penguin (Eudyptes chrysocome).

    PubMed

    Bliss, Cassandra D; Aquino, Susette; Woodhouse, Sarah

    2015-01-01

    To describe ophthalmic examination findings and standard diagnostic test results in 2 penguin species. Macaroni & Southern Rockhopper Penguins. Complete ophthalmic examinations including Schirmer tear test (STT), modified phenol red thread test (PTT), tonometry, and echobiometry were performed on penguins housed at the Detroit Zoo. Mean and standard deviation of ophthalmic tests are reported and compared for significance using two sample t-tests with significance set at P < 0.05. Correlations between variables were assessed using Pearson's correlation coefficient. Cataracts were the most common finding, present in 64% of Macaroni Penguins, and 68% of Rockhopper Penguins. There were anterior segment anomalies in all eyes with cataracts consistent with lens-induced uveitis. The mean modified PTT for the Macaronis was 24.7 ± 6.37 mm/15 s and 25.1 ± 7.07 mm/15 s in the Rockhoppers. The mean STT value for the Macaronis was 12.1 ± 5.43 mm/min and 11.0 ± 3.96 mm/min in the Rockhoppers. Mean intraocular pressure (IOP) for the Macaronis was 21.9 ± 7.05 mmHg measured by applanation tonometry and 29.1 ± 7.16 mmHg using rebound tonometry. The Rockhoppers had a mean IOP of 20.0 ± 5.77 mmHg and 24.1 ± 5.09 mmHg for applanation and rebound tonometry, respectively. In both populations, there was a significant difference in IOP measurement between the two instruments. In the Macaroni penguins, the presence of cataracts correlated significantly with increased age and lower IOP readings. Anterior chamber distance and axial globe length were significantly greater in males than in females in both penguin species. © 2013 American College of Veterinary Ophthalmologists.

  1. The Supercritical CO2 Huff-n-puff Experiment of Shale Oil Utilizing Isopropanol

    NASA Astrophysics Data System (ADS)

    Shang, Shengxiang; Dong, Mingzhe; Gong, Houjian

    2018-01-01

    In this study, the supercritical CO2 huff-n-puff experiment of shale oil has been investigated. Experimental data shows that the addition of isopropanol can greatly improve the recovery of shale oil. And this provides a new way to improve the recovery of shale oil. In this paper, it is also tried to analyze the influencing factor of isopropanol on the recovery of shale oil by analyzing the MMP.

  2. Experimental research of neutron yield and spectrum from deuterium gas-puff z-pinch on the GIT-12 generator at current above 2 MA

    NASA Astrophysics Data System (ADS)

    Cherdizov, R. K.; Fursov, F. I.; Kokshenev, V. A.; Kurmaev, N. E.; Labetsky, A. Yu; Ratakhin, N. A.; Shishlov, A. V.; Cikhardt, J.; Cikhardtova, B.; Klir, D.; Kravarik, J.; Kubes, P.; Rezac, K.; Dudkin, G. N.; Garapatsky, A. A.; Padalko, V. N.; Varlachev, V. A.

    2017-05-01

    The Z-pinch experiments with deuterium gas-puff surrounded by an outer plasma shell were carried out on the GIT-12 generator (Tomsk, Russia) at currents of 2 MA. The plasma shell consisting of hydrogen and carbon ions was formed by 48 plasma guns. The deuterium gas-puff was created by a fast electromagnetic valve. This configuration provides an efficient mode of the neutron production in DD reaction, and the neutron yield reaches a value above 1012 neutrons per shot. Neutron diagnostics included scintillation TOF detectors for determination of the neutron energy spectrum, bubble detectors BD-PND, a silver activation detector, and several activation samples for determination of the neutron yield analysed by a Sodium Iodide (NaI) and a high-purity Germanium (HPGe) detectors. Using this neutron diagnostic complex, we measured the total neutron yield and amount of high-energy neutrons.

  3. Intraoperative assessment of intraocular pressure in vitrectomized air-filled and fluid-filled eyes.

    PubMed

    Moon, Chan Hee; Choi, Kyung Seek; Rhee, Mi Ri; Lee, Sung Jin

    2013-11-01

    To ascertain the difference of intraocular pressure (IOP) measurement between vitrectomized air-filled and fluid-filled eyes. Thirty-one eyes of 31 consecutive patients who underwent conventional vitrectomy and intraocular gas tamponade were assessed. After vitrectomy, IOP of the fluid-filled eyes was measured by Tono-Pen. Thereafter, fluid-air exchange was performed, and IOP of the air-filled eyes was measured again. The IOP within each fluid- and air-filled eye was varied by selecting settings on the vitrectomy system, from 10 to 50 mmHg with 5-mmHg increments. Postoperatively, IOP was assessed by both Tono-Pen and Goldmann applanation tonometry (GAT). Linear and nonlinear regression analyses were conducted between intraoperatively measured Tono-Pen readings and actual IOPs. Bland-Altman plot was used to assess the agreements between postoperatively measured Tono-Pen readings and GAT readings. The discrepancy between Tono-Pen readings and actual IOP in fluid-filled eyes was not significant, except for the profound high pressures over 45 mmHg. However, Tono-Pen readings in air-filled eyes were significantly lower than actual IOPs in all ranges, and Tono-Pen increasingly underestimates IOP at higher levels. Intraoperative Tono-Pen readings were correlated significantly with actual IOP and a quadratic equation evidenced the best fit (R(2) = 0.996). Postoperatively, difference of the measurements between Tono-Pen and GAT was not significant. Tono-Pen and GAT significantly underestimate actual IOP in air-filled eyes. It should be considered that actual IOP would be greater than the measured IOP in gas-filled eyes, even though the IOP is measured as normal. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Inverse identification of unknown finite-duration air pollutant release from a point source in urban environment

    NASA Astrophysics Data System (ADS)

    Kovalets, Ivan V.; Efthimiou, George C.; Andronopoulos, Spyros; Venetsanos, Alexander G.; Argyropoulos, Christos D.; Kakosimos, Konstantinos E.

    2018-05-01

    In this work, we present an inverse computational method for the identification of the location, start time, duration and quantity of emitted substance of an unknown air pollution source of finite time duration in an urban environment. We considered a problem of transient pollutant dispersion under stationary meteorological fields, which is a reasonable assumption for the assimilation of available concentration measurements within 1 h from the start of an incident. We optimized the calculation of the source-receptor function by developing a method which requires integrating as many backward adjoint equations as the available measurement stations. This resulted in high numerical efficiency of the method. The source parameters are computed by maximizing the correlation function of the simulated and observed concentrations. The method has been integrated into the CFD code ADREA-HF and it has been tested successfully by performing a series of source inversion runs using the data of 200 individual realizations of puff releases, previously generated in a wind tunnel experiment.

  5. Probing myocardium biomechanics using quantitative optical coherence elastography

    NASA Astrophysics Data System (ADS)

    Wang, Shang; Lopez, Andrew L.; Morikawa, Yuka; Tao, Ge; Li, Jiasong; Larina, Irina V.; Martin, James F.; Larin, Kirill V.

    2015-03-01

    We present a quantitative optical coherence elastographic method for noncontact assessment of the myocardium elasticity. The method is based on shear wave imaging optical coherence tomography (SWI-OCT), where a focused air-puff system is used to induce localized tissue deformation through a low-pressure short-duration air stream and a phase-sensitive OCT system is utilized to monitor the propagation of the induced tissue displacement with nanoscale sensitivity. The 1-D scanning of M-mode OCT imaging and the application of optical phase retrieval and mapping techniques enable the reconstruction and visualization of 2-D depth-resolved shear wave propagation in tissue with ultra-high frame rate. The feasibility of this method in quantitative elasticity measurement is demonstrated on tissue-mimicking phantoms with the estimated Young's modulus compared with uniaxial compression tests. We also performed pilot experiments on ex vivo mouse cardiac muscle tissues with normal and genetically altered cardiomyocytes. Our results indicate this noncontact quantitative optical coherence elastographic method can be a useful tool for the cardiac muscle research and studies.

  6. Smoking Topography Characteristics of Very Low Nicotine Content Cigarettes, With and Without Nicotine Replacement, in Smokers With Schizophrenia and Controls.

    PubMed

    Tidey, Jennifer W; Cassidy, Rachel N; Miller, Mollie E

    2016-09-01

    Reducing the nicotine content of cigarettes to a minimally addictive level has been proposed as a regulatory strategy for reducing tobacco dependence. However, smokers with schizophrenia (SS) may be prone to changing their smoking topography in efforts to compensate for the reduction in nicotine content. The aims of this study were to compare smoking topography characteristics of usual-brand and very low nicotine content (VLNC) cigarettes in SS and control smokers without psychiatric illness (CS), and to determine whether nicotine replacement reversed any changes in topography produced by VLNC cigarettes. Using a within-subjects, counter-balanced design, SS (n = 27) and CS (n = 23) smoked usual brand cigarettes, VLNC cigarettes while wearing placebo patches (VLNC + PLA), or VLNC cigarettes while wearing transdermal nicotine patches totaling 42mg (VLNC + NIC) during 5-hour ad libitum smoking sessions. Cigarettes were smoked through topography measurement devices. Across conditions, SS smoked more puffs per session and per cigarette, had higher cigarette volumes, and had shorter inter-puff intervals than CS (Ps < .01). During VLNC cigarette sessions, puff duration increased and time between puffs decreased, but participants smoked fewer puffs, resulting in a net decrease in cigarette and total session volume (Ps < .001). There were no significant interactions between group and condition. These findings indicate that acute use of VLNC cigarettes does not increase intensity of smoking in SS, and support the feasibility of a nicotine reduction policy. Reducing the nicotine in cigarettes to a minimally addictive level has been proposed as a means of reducing tobacco dependence. However, smokers, particularly those with schizophrenia (SS) may alter their puffing in an attempt to extract more nicotine from VLNC cigarettes. This study compared smoking topography of usual brand versus VLNC cigarettes, combined with placebo or transdermal nicotine patches, in SS and controls. Although some changes in topography were indicative of compensatory smoking, total puffs and total cigarette volume were reduced with VLNC cigarettes, indicating that acute VLNC cigarette use does not increase smoking in SS. © The Author 2016. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Around Marshall

    NASA Image and Video Library

    1998-08-04

    Nurse performs tonometry examination, which measure the tension of the eyeball, during an employee's arnual physical examination given by MSFC Occupational Medicine Environmental Health Services under the Center Operations Directorate.

  8. Simulations of Ar gas-puff Z-pinch radiation sources with double shells and central jets on the Z generator

    DOE PAGES

    Tangri, V.; Harvey-Thompson, Adam James; Giuliani, J. L.; ...

    2016-10-19

    Radiation-magnetohydrodynamic simulations using the non-LTE Mach2-TCRE code in (r,z) geometry are performed for two pairs of recent Ar gas-puff Z-pinch experiments on the refurbished Z generator with an 8 cm diameter nozzle. One pair of shots had an outer-to-inner shell mass ratio of 1:1.6 and a second pair had a ratio of 1:1.

  9. MESOI Version 2. 0: an interactive mesoscale Lagrangian puff dispersion model with deposition and decay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramsdell, J.V.; Athey, G.F.; Glantz, C.S.

    1983-11-01

    MESOI Version 2.0 is an interactive Lagrangian puff model for estimating the transport, diffusion, deposition and decay of effluents released to the atmosphere. The model is capable of treating simultaneous releases from as many as four release points, which may be elevated or at ground-level. The puffs are advected by a horizontal wind field that is defined in three dimensions. The wind field may be adjusted for expected topographic effects. The concentration distribution within the puffs is initially assumed to be Gaussian in the horizontal and vertical. However, the vertical concentration distribution is modified by assuming reflection at the groundmore » and the top of the atmospheric mixing layer. Material is deposited on the surface using a source depletion, dry deposition model and a washout coefficient model. The model also treats the decay of a primary effluent species and the ingrowth and decay of a single daughter species using a first order decay process. This report is divided into two parts. The first part discusses the theoretical and mathematical bases upon which MESOI Version 2.0 is based. The second part contains the MESOI computer code. The programs were written in the ANSI standard FORTRAN 77 and were developed on a VAX 11/780 computer. 43 references, 14 figures, 13 tables.« less

  10. Impact of neutral density fluctuations on gas puff imaging diagnostics

    NASA Astrophysics Data System (ADS)

    Wersal, C.; Ricci, P.

    2017-11-01

    A three-dimensional turbulence simulation of the SOL and edge regions of a toroidally limited tokamak is carried out. The simulation couples self-consistently the drift-reduced two-fluid Braginskii equations to a kinetic equation for neutral atoms. A diagnostic neutral gas puff on the low-field side midplane is included and the impact of neutral density fluctuations on D_α light emission investigated. We find that neutral density fluctuations affect the D_α emission. In particular, at a radial distance from the gas puff smaller than the neutral mean free path, neutral density fluctuations are anti-correlated with plasma density, electron temperature, and D_α fluctuations. It follows that the neutral fluctuations reduce the D_α emission in most of the observed region and, therefore, have to be taken into account when interpreting the amplitude of the D_α emission. On the other hand, higher order statistical moments (skewness, kurtosis) and turbulence characteristics (such as correlation length, or the autocorrelation time) are not significantly affected by the neutral fluctuations. At distances from the gas puff larger than the neutral mean free path, a non-local shadowing effect influences the neutral density fluctuations. There, the D_α fluctuations are correlated with the neutral density fluctuations, and the high-order statistical moments and measurements of other turbulence properties are strongly affected by the neutral density fluctuations.

  11. Electronic Cigarettes and Indoor Air Quality: A Simple Approach to Modeling Potential Bystander Exposures to Nicotine

    PubMed Central

    Colard, Stéphane; O’Connell, Grant; Verron, Thomas; Cahours, Xavier; Pritchard, John D.

    2014-01-01

    There has been rapid growth in the use of electronic cigarettes (“vaping”) in Europe, North America and elsewhere. With such increased prevalence, there is currently a debate on whether the aerosol exhaled following the use of e-cigarettes has implications for the quality of air breathed by bystanders. Conducting chemical analysis of the indoor environment can be costly and resource intensive, limiting the number of studies which can be conducted. However, this can be modelled reasonably accurately based on empirical emissions data and using some basic assumptions. Here, we present a simplified model, based on physical principles, which considers aerosol propagation, dilution and extraction to determine the potential contribution of a single puff from an e-cigarette to indoor air. From this, it was then possible to simulate the cumulative effect of vaping over time. The model was applied to a virtual, but plausible, scenario considering an e-cigarette user and a non-user working in the same office space. The model was also used to reproduce published experimental studies and showed good agreement with the published values of indoor air nicotine concentration. With some additional refinements, such an approach may be a cost-effective and rapid way of assessing the potential exposure of bystanders to exhaled e-cigarette aerosol constituents. PMID:25547398

  12. Field Measurement and Model Evaluation Program for Assessment of the Environmental Effects of Military Smokes: Evaluation of Atmospheric Dispersion Models for Fog-Oil Smoke Dispersion

    DTIC Science & Technology

    1989-02-01

    EK 111. TRIAL 19, L 2. \\ (,’, i / ඘ I€ m m B-02 I SMOKE WEEK IV -TRIAL 3 -- LOS1 DOSAGE 0.06 COMESIC U ACT II.......... MAD PUFF 0m0 _LUDWIG (1977...PUFF, AND LUDWIG (1977) WITH FIELD DATA FROM SMOKE WEEK IV. TRIAL 3. LOS1 l (c) For short release times and the calculation of dosages, the randomization

  13. 'Carcinogens in a puff': smoking in Hong Kong movies.

    PubMed

    Ho, Sai-Yin; Wang, Man-Ping; Lai, Hak-Kan; Hedley, Anthony J; Lam, Tai-Hing

    2010-12-01

    Smoking scenes in movies, exploited by the tobacco industry to circumvent advertisement bans, are linked to adolescent smoking. Recently, a Hong Kong romantic comedy Love in a puff put smoking at centre stage, with numerous smoking scenes and words that glamourise smoking. Although WHO has issued guidelines on reducing the exposure of children to smoking in movies, none is adopted in Hong Kong. Comprehensive tobacco control strategies are urgently needed to protect young people in Hong Kong from cigarette promotion in movies.

  14. Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry.

    PubMed

    Kohlhaas, Markus; Boehm, Andreas G; Spoerl, Eberhard; Pürsten, Antje; Grein, Hans J; Pillunat, Lutz E

    2006-04-01

    To evaluate the effect of central corneal thickness (CCT), corneal curvature, and axial length on applanation tonometry in an in vivo study. In a masked, prospective clinical trial, we examined 125 eyes of 125 patients scheduled for cataract surgery. Corneal curvature was measured by means of keratometry and axial length by A-scan ultrasonography. By cannulating the anterior chamber before surgery, intraocular pressure (IOP) was set to 20, 35, and 50 mm Hg in a closed system by means of a water column. After measuring thickness, the IOP was measured with an applanation tonometer. Pearson product moment correlations and multiple linear regression analyses were performed, and significance levels were evaluated by the paired, 2-tailed t test. The difference between measured and real IOP was significantly dependent (P < .001) on CCT. The associations between IOP and corneal curvature or IOP and axial length were not statistically significant (P = .31). The association between IOP reading and CCT is shown in the "Dresdner correction table," which illustrates an approximately 1-mm Hg correction for every 25-microm deviation from a CCT of 550 microm. The correction values were positive as thickness decreased and negative as thickness increased. Central corneal thickness significantly affects IOP readings obtained by applanation tonometry according to the Goldmann principle. A correction of IOP readings by considering CCT according to the Dresdner correction table might be helpful for determining an accurate IOP value.

  15. Tonometry

    MedlinePlus

    ... Tanaka G. Intraocular pressure: measurement, regulation, and flow relationships. In: Tasman W, Jaeger EA, eds. Duane's Foundations ... ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow ...

  16. A gas-puff-driven theta pinch for plasma-surface interaction studies

    NASA Astrophysics Data System (ADS)

    Jung, Soonwook; Kesler, Leigh; Yun, Hyun-Ho; Curreli, Davide; Andruczyk, Daniel; Ruzic, David

    2012-10-01

    DEVeX is a theta pinch device used to investigate fusion-related material interaction such as vapor shielding and ICRF antenna interactions with plasma-pulses in a laboratory setting. The simulator is required to produce high heat-flux plasma enough to induce temperature gradient high enough to study extreme conditions happened in a plasma fusion reactor. In order to achieve it, DEVeX is reconfigured to be combined with gas puff system as gas puffing may reduce heat flux loss resulting from collisions with neutral. A gas puff system as well as a conical gas nozzle is manufactured and several diagnostics including hot wire anemometer and fast ionization gauge are carried out to quantitatively estimate the supersonic flow of gas. Energy deposited on the target for gas puffing and static-filled conditions is measured with thermocouples and its application to TELS, an innovative concept utilizing a thermoelectric-driven liquid metal flow for plasma facing component, is discussed.

  17. Dynamics of Isolated and Interacting Flame Structures in Strongly-Pulsed, Turbulent Jet Flames

    NASA Astrophysics Data System (ADS)

    Fregeau, Mathieu; Liao, Ying-Hao; Hermanson, James; Stocker, Dennis; Hegde, Uday

    2007-11-01

    The dynamics of the large-scale structures in strongly-pulsed, turbulent diffusion flames were studied in normal- and microgravity. Cross-correlation of temperature measurements and high-speed flame imaging were used to estimate the celerity of the flame structures. Both diagnostics indicate a marked increase in celerity with the increasing flame puff interaction as the jet off-time decreases. The celerity is also generally higher for shorter injection times, which yield more compact flame puffs. These trends are seen both for the case of fixed injection velocity as well as for the case of fixed fueling rate. The celerity correlates well with the inverse downstream distance scaled with an appropriate injection parameter, suggesting that the impact of buoyancy can be partially accounted for by the corresponding changes in the mean flame length. Differences in the values of celerity determined by the temperature and visual techniques can be attributed to nature of the evolution of the flame puffs with downstream distance.

  18. The results of the study of compact gas-puff and vacuum spark plasma sources of SXR with Glass-Capillary Converters (GCC)

    NASA Astrophysics Data System (ADS)

    Shlyaptseva, Alla; Kantsyrev, Victor; Inozemtsev, Andrei; Petrukhin, Oleg

    1994-06-01

    The results are presented dealing with the working out and study of the SXR compact plasma source. The experimental set up included a compact new 'gas-puff' source with parameters being better than the traditional ones and a new type of SXR source - low-inductance vacuum spark (LIVS) with glass-capillary converters (GCC) of SXR. The compact plasma 'gas-puff' source had the high value of the z approx. (1-2) 10(exp -2) (conversion coefficient of initial energy supply into SXR); a small effective size of emission region and greater resource. The characteristics of LIVS with GCC were studied. GCC consisting of about several hundreds of glass capillaries allowed us to focus SXR, to change the cross section of SXR beams to plasma sources, and to change SXR spectrum. The possibility was shown of using of GCC in plasma diagnostics of powerful plasma devices: for X-ray microscopy and to study the influence of SXR on the solid state surface.

  19. Iron pentacarbonyl detection limits in the cigarette smoke matrix using FT-IR spectroscopy

    NASA Astrophysics Data System (ADS)

    Parrish, Milton E.; Plunkett, Susan E.; Harward, Charles N.

    2005-11-01

    Endogenous metals present in tobacco from agricultural practices have been purported to generate metal carbonyls in cigarette smoke. Transition metal catalysts, such as iron oxide, have been investigated for the reduction of carbon monoxide (CO) in cigarette smoke. These studies motivated the development of an analytical method to determine if iron pentacarbonyl [Fe(CO) 5] is present in mainstream smoke from cigarette models having cigarette paper made with iron oxide. An FT-IR puff-by-puff method was developed and the detection limit was determined using two primary reference spectra from different sources to estimate the amount of Fe(CO) 5 present in a high-pressure steel cylinder of CO. We do not detect Fe(CO) 5 in a single 35 mL puff from reference cigarettes or from those cigarette models having cigarette paper made with iron oxide, with a 30-ppbV limit of detection (LOD). Also, it was shown that a filter containing activated carbon would remove Fe(CO) 5.

  20. Assessment of intraocular pressure measured by Reichert Ocular Response Analyzer, Goldmann Applanation Tonometry, and Dynamic Contour Tonometry in healthy individuals

    PubMed Central

    Ouyang, Ping-Bo; Li, Cong-Yi; Zhu, Xiao-Hua; Duan, Xuan-Chu

    2012-01-01

    AIM To investigate the accuracy of intraocular pressure (IOP) as measured by a Reichert Ocular Response Analyzer (ORA), as well as the relationship between central corneal thickness (CCT) and IOP as measured by ORA, Goldmann applanation tonometry (GAT), and dynamic contour tonometry (DCT). METHODS A total of 158 healthy individuals (296 eyes) were chosen randomly for measurement of IOP. After CCT was measured using A-ultrasound (A-US), IOP was measured by ORA, GAT, and DCT devices in a randomized order. The IOP values acquired using each of the three tonometries were compared, and the relationship between CCT and IOP values were analyzed separately. Two IOP values, Goldmann-correlated IOP value (IOPg) and corneal-compensated intraocular pressure (IOPcc), were got using ORA. Three groups were defined according to CCT: 1) thin cornea (CCT<520µm); 2) normal-thickness cornea (CCT: 520–580µm); and 3) thick cornea (CCT>580µm) groups. RESULTS In normal subjects, IOP measurements were 14.95±2.99mmHg with ORA (IOPg), 15.21±2.77mmHg with ORA (IOPcc), 15.22±2.77mmHg with GAT, and 15.49±2.56mmHg with DCT. Mean differences were 0.01±2.29mmHg between IOPcc and GAT (P>0.05) and 0.28±2.20mmHg between IOPcc and DCT (P>0.05). There was a greater correlation between IOPcc and DCT (r=0.946, P=0.000) than that between IOPcc and GAT (r=0.845, P=0.000). DCT had a significant correlation with GAT (r=0.854, P=0.000). GAT was moderately correlated with CCT (r=0.296, P<0.001), while IOPcc showed a weak but significant correlation with CCT (r=−0.155, P=0.007). There was a strong negative correlation between CCT and the difference between IOPcc and GAT(r=-0.803, P=0.000), with every 10µm increase in CCT resulting in an increase in this difference of 0.35mmHg. The thick cornea group (CCT>580µm) showed the least significant correlation between IOPcc and GAT (r=0.859, P=0.000); while the thin cornea group (CCT<520µm) had the most significant correlation between IOPcc and GAT (r=0.926, P=0.000). The correlated differences between IOPcc and DCT were not significant in any of the three groups (P>0.05). CONCLUSION Measurement of IOP by ORA has high repeatability and is largely consistent with GAT measurements. Moreover, the ORA measurements are affected only to a small extent by CCT, and are likely to be much closer to the real IOP value than GAT. PMID:22553765

  1. 21 CFR 524.1982 - Proparacaine hydrochloride ophthalmic solution.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... used as an anesthetic in cauterization of corneal ulcers, removal of foreign bodies and sutures from the cornea, and measurement of intraocular pressure (tonometry) when glaucoma is suspected. Local...

  2. 21 CFR 524.1982 - Proparacaine hydrochloride ophthalmic solution.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... used as an anesthetic in cauterization of corneal ulcers, removal of foreign bodies and sutures from the cornea, and measurement of intraocular pressure (tonometry) when glaucoma is suspected. Local...

  3. Assessment of SRS ambient air monitoring network

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abbott, K.; Jannik, T.

    Three methodologies have been used to assess the effectiveness of the existing ambient air monitoring system in place at the Savannah River Site in Aiken, SC. Effectiveness was measured using two metrics that have been utilized in previous quantification of air-monitoring network performance; frequency of detection (a measurement of how frequently a minimum number of samplers within the network detect an event), and network intensity (a measurement of how consistent each sampler within the network is at detecting events). In addition to determining the effectiveness of the current system, the objective of performing this assessment was to determine what, ifmore » any, changes could make the system more effective. Methodologies included 1) the Waite method of determining sampler distribution, 2) the CAP88- PC annual dose model, and 3) a puff/plume transport model used to predict air concentrations at sampler locations. Data collected from air samplers at SRS in 2015 compared with predicted data resulting from the methodologies determined that the frequency of detection for the current system is 79.2% with sampler efficiencies ranging from 5% to 45%, and a mean network intensity of 21.5%. One of the air monitoring stations had an efficiency of less than 10%, and detected releases during just one sampling period of the entire year, adding little to the overall network intensity. By moving or removing this sampler, the mean network intensity increased to about 23%. Further work in increasing the network intensity and simulating accident scenarios to further test the ambient air system at SRS is planned« less

  4. Prediction of dosage-based parameters from the puff dispersion of airborne materials in urban environments using the CFD-RANS methodology

    NASA Astrophysics Data System (ADS)

    Efthimiou, G. C.; Andronopoulos, S.; Bartzis, J. G.

    2018-02-01

    One of the key issues of recent research on the dispersion inside complex urban environments is the ability to predict dosage-based parameters from the puff release of an airborne material from a point source in the atmospheric boundary layer inside the built-up area. The present work addresses the question of whether the computational fluid dynamics (CFD)-Reynolds-averaged Navier-Stokes (RANS) methodology can be used to predict ensemble-average dosage-based parameters that are related with the puff dispersion. RANS simulations with the ADREA-HF code were, therefore, performed, where a single puff was released in each case. The present method is validated against the data sets from two wind-tunnel experiments. In each experiment, more than 200 puffs were released from which ensemble-averaged dosage-based parameters were calculated and compared to the model's predictions. The performance of the model was evaluated using scatter plots and three validation metrics: fractional bias, normalized mean square error, and factor of two. The model presented a better performance for the temporal parameters (i.e., ensemble-average times of puff arrival, peak, leaving, duration, ascent, and descent) than for the ensemble-average dosage and peak concentration. The majority of the obtained values of validation metrics were inside established acceptance limits. Based on the obtained model performance indices, the CFD-RANS methodology as implemented in the code ADREA-HF is able to predict the ensemble-average temporal quantities related to transient emissions of airborne material in urban areas within the range of the model performance acceptance criteria established in the literature. The CFD-RANS methodology as implemented in the code ADREA-HF is also able to predict the ensemble-average dosage, but the dosage results should be treated with some caution; as in one case, the observed ensemble-average dosage was under-estimated slightly more than the acceptance criteria. Ensemble-average peak concentration was systematically underpredicted by the model to a degree higher than the allowable by the acceptance criteria, in 1 of the 2 wind-tunnel experiments. The model performance depended on the positions of the examined sensors in relation to the emission source and the buildings configuration. The work presented in this paper was carried out (partly) within the scope of COST Action ES1006 "Evaluation, improvement, and guidance for the use of local-scale emergency prediction and response tools for airborne hazards in built environments".

  5. Examining Daily Electronic Cigarette Puff Topography Among Established and Non-established Cigarette Smokers in their Natural Environment.

    PubMed

    Lee, Youn Ok; Nonnemaker, James M; Bradfield, Brian; Hensel, Edward C; Robinson, Risa J

    2017-10-04

    Understanding exposures and potential health effects of ecigarettes is complex. Users' puffing behavior, or topography, affects function of ecigarette devices (e.g., coil temperature) and composition of their emissions. Users with different topographies are likely exposed to different amounts of any harmful or potentially harmful constituents (HPHCs). In this study, we compare ecigarette topographies of established cigarette smokers and non-established cigarette smokers. Data measuring e-cigarette topography were collected using a wireless hand-held monitoring device in users' everyday lives over 1 week. Young adult (aged 18-25) participants (N=20) used disposable e-cigarettes with the monitor as they normally would and responded to online surveys. Topography characteristics of established versus non-established cigarette smokers were compared. On average, established cigarette smokers in the sample had larger first puff volume (130.9ml vs. 56.0ml, p<.05) and larger puff volume per session (1,509.3ml vs. 651.7ml, p<.05) compared with non-established smokers. At marginal significance, they had longer sessions (566.3s vs. 279.7s, p=.06) and used e-cigarettes more sessions per day (5.3s vs. 3.5s, p=.14). Established cigarette smokers also used ecigarettes for longer puff durations (3.3s vs. 1.8s, p<.01) and had larger puff volume (110.3ml vs. 54.7ml, p<.05) compared with non-established smokers. At marginal significance, they had longer puff interval (38.1s vs. 21.7s, p=.05). Our results demonstrate that topography characteristics differ by level of current cigarette smoking. This suggests that exposures to constituents of e-cigarettes depends on user characteristics and that specific topography parameters may be needed for different user populations when assessing ecigarette health effects. A user's topography affects his or her exposure to HPHCs. As this study demonstrates, user characteristics, such as level of smoking, can influence topography. Thus, it is crucial to understand the topography profiles of different user types to assess the potential for population harm and to identify potentially vulnerable populations. This study only looked at topography of cigarette smokers using disposable e-cigarettes. Further research is needed to better understand potential variation in ecigarette topography and resulting exposures to HPHCs among users of different e-cigarette devices and liquids. © The Author 2017. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Effects of Electronic Cigarette Liquid Nicotine Concentration on Plasma Nicotine and Puff Topography in Tobacco Cigarette Smokers: A Preliminary Report.

    PubMed

    Lopez, Alexa A; Hiler, Marzena M; Soule, Eric K; Ramôa, Carolina P; Karaoghlanian, Nareg V; Lipato, Thokozeni; Breland, Alison B; Shihadeh, Alan L; Eissenberg, Thomas

    2016-05-01

    Electronic cigarettes (ECIGs) aerosolize a liquid that usually contains propylene glycol and/or vegetable glycerin, flavorants, and the dependence-producing drug nicotine in various concentrations. This study examined the extent to which ECIG liquid nicotine concentration is related to user plasma nicotine concentration in ECIG-naïve tobacco cigarette smokers. Sixteen ECIG-naïve cigarette smokers completed four laboratory sessions that differed by the nicotine concentration of the liquid (0, 8, 18, or 36 mg/ml) that was placed into a 1.5 Ohm, dual coil "cartomizer" powered by a 3.3V battery. In each session, participants completed two, 10-puff ECIG use bouts with a 30-second inter-puff interval; bouts were separated by 60 minutes. Venous blood was sampled before and after bouts for later analysis of plasma nicotine concentration; puff duration, volume, and average flow rate were measured during each bout. In bout 1, relative to the 0mg/ml nicotine condition (mean = 3.8 ng/ml, SD = 3.3), plasma nicotine concentration increased significantly immediately after the bout for the 8 (mean = 8.8 ng/ml, SD = 6.3), 18 (mean = 13.2 ng/ml, SD = 13.2), and 36 mg/ml (mean = 17.0 ng/ml, SD = 17.9) liquid concentration. A similar pattern was observed after bout 2. Average puff duration in the 36 mg/ml condition was significantly shorter compared to the 0mg/ml nicotine condition. Puff volume increased during the second bout for 8 and 18 mg/ml conditions. For a given ECIG device, nicotine delivery may be directly related to liquid concentration. ECIG-naïve cigarette smokers can, from their first use bout, attain cigarette-like nicotine delivery profiles with some currently available ECIG products. Liquid nicotine concentration can influence plasma nicotine concentration in ECIG-naïve cigarette smokers, and, at some concentrations, the nicotine delivery profile of a 3.3V ECIG with a dual coil, 1.5-Ohm cartomizer approaches that of a combustible tobacco cigarette in this population. Finding a product that delivers nicotine as effectively as a tobacco cigarette, as we report here, may be essential for smokers who want to replace completely their combustible tobacco cigarettes with ECIGs. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. A comparison between Goldmann applanation tonometry and dynamic contour tonometry after photorefractive keratectomy.

    PubMed

    Sadigh, Afshin Lotfi; Fouladi, Rohollah F; Hashemi, Hassan; Beheshtnejad, Amir Houshang

    2013-02-01

    The intraocular pressure (IOP) could be measured by both Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT). Although these two methods have been discussed widely after laser-assisted sub-epithelial keratectomy (LASIK), there is little data in the cases undergoing photorefractive keratectomy (PRK). We aimed to compare the changes of IOP measurements obtained by GAT and DCT after PRK for myopia/myopic astigmatism. This prospective study enrolled 77 candidates (154 eyes) for PRK to correct myopia or myopic astigmatism and 30 matched patients (30 eyes) with myopia or myopic astigmatism who served as controls. Changes of the IOP measurements (ΔIOP) obtained by GAT and DCT before and at 6 months after PRK in the operated eyes, and at baseline and 6 months later in the controls, were documented. Changes of the central corneal thickness (ΔCCT) were determined in the same fashion. The mean IOP readings obtained by DCT were comparable before and at 6 months after procedure (18.34 ± 3.03 mmHg and 17.87 ± 2.61 mmHg respectively, p = 0.41); whereas the mean IOP reading obtained by GAT decreased significantly 6 months postoperatively (17.92 ± 3.63 mmHg and 16.25 ± 2.66 mmHg, p < 0.001). A significant correlation was present between the ΔIOP obtained by GAT and ΔCCT (r = 0.61, p < 0.001). Similar correlation was not significant between the DCT-obtained ΔIOP and the ΔCCT (r = 0.07, p = 0.44). The mean ΔIOP obtained by GAT was significantly higher in the operated eyes than in the controls (-1.54 ± 1.45 vs 0.07 ± 0.44 mmHg, p = 0.02). The mean DCT-obtained ΔIOP was just marginally insignificant between the operated and nonoperated eyes (-0.63 ± 0.59 vs 0.02 ± 0.38 mmHg respectively; p = 0.09). The authors recommend DCT after PRK in the cases with myopia or myopic astigmatism.

  8. Secondhand Exposure to Vapors From Electronic Cigarettes

    PubMed Central

    Czogala, Jan; Fidelus, Bartlomiej; Zielinska-Danch, Wioleta; Travers, Mark J.; Sobczak, Andrzej

    2014-01-01

    Introduction: Electronic cigarettes (e-cigarettes) are designed to generate inhalable nicotine aerosol (vapor). When an e-cigarette user takes a puff, the nicotine solution is heated and the vapor is taken into lungs. Although no sidestream vapor is generated between puffs, some of the mainstream vapor is exhaled by e-cigarette user. The aim of this study was to evaluate the secondhand exposure to nicotine and other tobacco-related toxicants from e-cigarettes. Materials and Methods: We measured selected airborne markers of secondhand exposure: nicotine, aerosol particles (PM2.5), carbon monoxide, and volatile organic compounds (VOCs) in an exposure chamber. We generated e-cigarette vapor from 3 various brands of e-cigarette using a smoking machine and controlled exposure conditions. We also compared secondhand exposure with e-cigarette vapor and tobacco smoke generated by 5 dual users. Results: The study showed that e-cigarettes are a source of secondhand exposure to nicotine but not to combustion toxicants. The air concentrations of nicotine emitted by various brands of e-cigarettes ranged from 0.82 to 6.23 µg/m3. The average concentration of nicotine resulting from smoking tobacco cigarettes was 10 times higher than from e-cigarettes (31.60±6.91 vs. 3.32±2.49 µg/m3, respectively; p = .0081). Conclusions: Using an e-cigarette in indoor environments may involuntarily expose nonusers to nicotine but not to toxic tobacco-specific combustion products. More research is needed to evaluate health consequences of secondhand exposure to nicotine, especially among vulnerable populations, including children, pregnant women, and people with cardiovascular conditions. PMID:24336346

  9. Physical Examination to Marshall Space Flight Center (MSFC) Employees

    NASA Technical Reports Server (NTRS)

    1998-01-01

    Nurse performs tonometry examination, which measure the tension of the eyeball, during an employee's arnual physical examination given by MSFC Occupational Medicine Environmental Health Services under the Center Operations Directorate.

  10. The vascular basis of the positional influence of the intraocular pressure.

    PubMed

    Krieglstein, G K; Waller, W K; Leydhecker, W

    1978-05-02

    By measuring intraocular pressure in different body positions from 60 degrees semiupright to 30 degrees head down, a nonlinear relationship between IOP increase and body position was confirmed. IOP postural response in individual subjects was roughly correlated to ophthalmic arterial pressure and to the episcleral venous pressure postural response. In one series of subjects, the episcleral venous pressure increments due to posture wa; parallel to the applanation-indentation disparity in the same individual eyes. Differential tonometry with applanation or indentation procedures under blind conditions gave significantly low indentation readings. It is concluded that IOP postural response depends on arterial and venous vascular changes when subjects move from an erect to a horizontal body position. Blood expulsion from the choroid by indentation tonometry might be the reason that this tonometric procedure does not measure IOP changes based on vascular changes.

  11. Dose-response effects of corneal anesthetics.

    PubMed

    Polse, K A; Keener, R J; Jauregui, M J

    1978-01-01

    With double-masking procedures, the dose-response curves for 0.1, 0.2, and 0.4% benoxinate and 0.125, 0.25, and 0.50% proparacaine hydrochloride were determined by monitoring changes in corneal touch threshold after applying each anesthetic. The level of corneal anesthesia necessary for applanation tonometry was also determined. The maximum increase in threshold that could be measured following instillation of 50 microliter of the drug was 200 mg/mm2 All 6 anesthetic solutions produced this amount of decreased corneal sensitivity. Recovery from the anesthetic was exponential for all concentrations; however, the lower doses had the shortest duration. For applanation tonometry, the corneal threshold for touch must be 75 mg/mm2 or higher. We conclude that a quarter to a half of the commonly used anesthetic dose is sufficient for routine tonometric evaluation.

  12. Clinical investigation of the effect of topical anesthesia on intraocular pressure

    PubMed Central

    Almubrad, Turki M; Ogbuehi, Kelechi C

    2007-01-01

    Background/Aims: Contact tonometry is generally considered more accurate than non-contact tonometry in the assessment of intraocular pressure (IOP). This study was designed to investigate the effect of ocular anesthesia, a pre-requisite for contact tonometry, on the IOP in a sample of visually normal subjects. Method: In a random sample of 120 young visually normal subjects (divided equally among three groups), the Topcon CT80 non-contact tonometer was used to measure IOP before, at the second minute and at the fifth minute following instillation of one drop of one of three eyedrops – carboxymethylcellulose sodium 0.5% (control), oxybuprocaine hydrochloride 0.4% and proparacaine hydrochloride 0.5%. Results: The IOP measured before instilling the ophthalmic drops did not vary significantly among the three groups of subjects (p > 0.05). In the control group, the average IOP of 15.1 ± 2.6 mmHg did not vary significantly (p > 0.05) 2 minutes and 5 minutes following instillation of one drop of Carboxymethylcellulose sodium. There were statistically significant reductions of IOP 2 minutes (p < 0.01) and 5 minutes (p < 0.001) after the instillation of one drop of oxybuprocaine hydrochloride. One drop of proparacaine hydrochloride caused significant reductions in the average IOP after 2 minutes (p < 0.001) and after 5 minutes (p < 0.001). Conclusions: One drop of topical proparacaine or oxybuprocaine may cause a small but a statistically significant reduction in IOP which could lead to lower IOP readings. PMID:19668485

  13. Clinical investigation of the effect of topical anesthesia on intraocular pressure.

    PubMed

    Almubrad, Turki M; Ogbuehi, Kelechi C

    2007-09-01

    Contact tonometry is generally considered more accurate than non-contact tonometry in the assessment of intraocular pressure (IOP). This study was designed to investigate the effect of ocular anesthesia, a pre-requisite for contact tonometry, on the IOP in a sample of visually normal subjects. In a random sample of 120 young visually normal subjects (divided equally among three groups), the Topcon CT80 non-contact tonometer was used to measure IOP before, at the second minute and at the fifth minute following instillation of one drop of one of three eyedrops - carboxymethylcellulose sodium 0.5% (control), oxybuprocaine hydrochloride 0.4% and proparacaine hydrochloride 0.5%. The IOP measured before instilling the ophthalmic drops did not vary significantly among the three groups of subjects (p > 0.05). In the control group, the average IOP of 15.1 +/- 2.6 mmHg did not vary significantly (p > 0.05) 2 minutes and 5 minutes following instillation of one drop of Carboxymethylcellulose sodium. There were statistically significant reductions of IOP 2 minutes (p < 0.01) and 5 minutes (p < 0.001) after the instillation of one drop of oxybuprocaine hydrochloride. One drop of proparacaine hydrochloride caused significant reductions in the average IOP after 2 minutes (p < 0.001) and after 5 minutes (p < 0.001). One drop of topical proparacaine or oxybuprocaine may cause a small but a statistically significant reduction in IOP which could lead to lower IOP readings.

  14. Homing pigeons only navigate in air with intact environmental odours: a test of the olfactory activation hypothesis with GPS data loggers.

    PubMed

    Gagliardo, Anna; Ioalè, Paolo; Filannino, Caterina; Wikelski, Martin

    2011-01-01

    A large body of evidence has shown that anosmic pigeons are impaired in their navigation. However, the role of odours in navigation is still subject to debate. While according to the olfactory navigation hypothesis homing pigeons possess a navigational map based on the distribution of environmental odours, the olfactory activation hypothesis proposes that odour perception is only needed to activate a navigational mechanism based on cues of another nature. Here we tested experimentally whether the perception of artificial odours is sufficient to allow pigeons to navigate, as expected from the olfactory activation hypothesis. We transported three groups of pigeons in air-tight containers to release sites 53 and 61 km from home in three different olfactory conditions. The Control group received natural environmental air; both the Pure Air and the Artificial Odour groups received pure air filtered through an active charcoal filter. Only the Artificial Odour group received additional puffs of artificial odours until release. We then released pigeons while recording their tracks with 1 Hz GPS data loggers. We also followed non-homing pigeons using an aerial data readout to a Cessna plane, allowing, for the first time, the tracking of non-homing homing pigeons. Within the first hour after release, the pigeons in both the Artificial Odour and the Pure Air group (receiving no environmental odours) showed impaired navigational performances at each release site. Our data provide evidence against an activation role of odours in navigation, and document that pigeons only navigate well when they perceive environmental odours.

  15. Mapping air quality zones for coastal urban centers.

    PubMed

    Freeman, Brian; Gharabaghi, Bahram; Thé, Jesse; Munshed, Mohammad; Faisal, Shah; Abdullah, Meshal; Al Aseed, Athari

    2017-05-01

    This study presents a new method that incorporates modern air dispersion models allowing local terrain and land-sea breeze effects to be considered along with political and natural boundaries for more accurate mapping of air quality zones (AQZs) for coastal urban centers. This method uses local coastal wind patterns and key urban air pollution sources in each zone to more accurately calculate air pollutant concentration statistics. The new approach distributes virtual air pollution sources within each small grid cell of an area of interest and analyzes a puff dispersion model for a full year's worth of 1-hr prognostic weather data. The difference of wind patterns in coastal and inland areas creates significantly different skewness (S) and kurtosis (K) statistics for the annually averaged pollutant concentrations at ground level receptor points for each grid cell. Plotting the S-K data highlights grouping of sources predominantly impacted by coastal winds versus inland winds. The application of the new method is demonstrated through a case study for the nation of Kuwait by developing new AQZs to support local air management programs. The zone boundaries established by the S-K method were validated by comparing MM5 and WRF prognostic meteorological weather data used in the air dispersion modeling, a support vector machine classifier was trained to compare results with the graphical classification method, and final zones were compared with data collected from Earth observation satellites to confirm locations of high-exposure-risk areas. The resulting AQZs are more accurate and support efficient management strategies for air quality compliance targets effected by local coastal microclimates. A novel method to determine air quality zones in coastal urban areas is introduced using skewness (S) and kurtosis (K) statistics calculated from grid concentrations results of air dispersion models. The method identifies land-sea breeze effects that can be used to manage local air quality in areas of similar microclimates.

  16. A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode

    PubMed Central

    Rieker, G. B.; Poehlmann, F. R.; Cappelli, M. A.

    2013-01-01

    Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spectrometer was designed and calibrated using the Geant4 toolkit, accounting for the effects on the ion trajectories of spatial non-uniformities in the spectrometer magnetic and electric fields. Results for hydrogen gas puffs indicate the existence of a class of accelerated protons with energies well above the coaxial discharge potential (up to 24 keV). The Thomson analyzer confirms the presence of impurities of copper and iron, also of relatively high energies, which are likely erosion or sputter products from plasma-electrode interactions. PMID:23983449

  17. A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode

    NASA Astrophysics Data System (ADS)

    Rieker, G. B.; Poehlmann, F. R.; Cappelli, M. A.

    2013-07-01

    Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spectrometer was designed and calibrated using the Geant4 toolkit, accounting for the effects on the ion trajectories of spatial non-uniformities in the spectrometer magnetic and electric fields. Results for hydrogen gas puffs indicate the existence of a class of accelerated protons with energies well above the coaxial discharge potential (up to 24 keV). The Thomson analyzer confirms the presence of impurities of copper and iron, also of relatively high energies, which are likely erosion or sputter products from plasma-electrode interactions.

  18. A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode.

    PubMed

    Rieker, G B; Poehlmann, F R; Cappelli, M A

    2013-07-01

    Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spectrometer was designed and calibrated using the Geant4 toolkit, accounting for the effects on the ion trajectories of spatial non-uniformities in the spectrometer magnetic and electric fields. Results for hydrogen gas puffs indicate the existence of a class of accelerated protons with energies well above the coaxial discharge potential (up to 24 keV). The Thomson analyzer confirms the presence of impurities of copper and iron, also of relatively high energies, which are likely erosion or sputter products from plasma-electrode interactions.

  19. Evaluation of heat and particle controllability on the JT-60SA divertor

    NASA Astrophysics Data System (ADS)

    Kawashima, H.; Hoshino, K.; Shimizu, K.; Takizuka, T.; Ide, S.; Sakurai, S.; Asakura, N.

    2011-08-01

    The JT-60SA divertor design has been established on the basis of engineering requirements and physics analysis. Heat and particle fluxes under the full input power of 41 MW can give severe heat loads on the divertor targets, while the allowable heat load is limited below 15 MW/m2. Dependence of the heat flux mitigation on a D2 gas-puff is evaluated by SONIC simulations for high density (ne_ave ˜ 1 × 1020 m-3) high current plasmas. It is found that the peak heat load 10 MW/m2 with dense (ned > 4 × 1020 m-3) and cold (Ted, Tid ⩽ 1 eV) divertor plasmas are obtained at a moderate gas-puff of Γpuff = 15 × 1021 s-1. Divertor plasmas are controlled from attached to detached condition using the divertor pump with pumping-speed below 100 m3/s. In full non-inductive current drive plasmas with low density (ne_ave ˜ 5 × 1019 m-3), the reduction of divertor heat load is achieved with the Ar injection.

  20. Incorporation of air into a snack food reduces energy intake.

    PubMed

    Osterholt, Kathrin M; Roe, Liane S; Rolls, Barbara J

    2007-05-01

    This study investigated how the air content of a familiar snack food affected energy intake and whether varying the method of serving the snack modified intake. We tested two versions of an extruded snack (cheese puffs) that were equal in energy density (5.7 kcal/g), but differed in energy per volume (less-aerated snack: 1.00 kcal/ml; more-aerated snack: 0.45 kcal/ml). In a within-subjects design, 16 women and 12 men consumed the snacks ad libitum in the laboratory during four afternoon sessions. A standard volume (1250 ml) of each snack was served once in a bowl and once in an opaque bag. Results showed significant differences in intake of the two snacks by energy (p=0.0003) and volume (p<0.0001); subjects consumed 21% less weight and energy (70+/-17 kcal) of the more-aerated snack than the less-aerated snack, although they consumed a 73% greater volume of the more-aerated snack (239+/-24 ml). These findings suggest that subjects responded to both the weight and volume of the snack. Despite differences in intake, hunger and fullness ratings did not differ across conditions. The serving method did not significantly affect intake. Results from this study indicate that incorporating air into food provides a strategy to reduce energy intake from energy-dense snacks.

  1. Use of red palm oil in local snacks can increase intake of provitamin A carotenoids in young aborigines children: a Malaysian experience.

    PubMed

    Ng, T K W; Low, C X; Kong, J P; Cho, Y L

    2012-12-01

    Carotenoid-rich red palm oil (RPO)-based snacks have been provided to children in impoverished communities to improve their vitamin A status. The non-availabilty of information on the acceptability of RPO-based snacks by Malaysian aborigines (Orang Asli) children forms the basis of this study. Twenty-one Orang Asli children, majority of whom had normal body mass index for age (BMI-for-age) and aged 4.73 +/- 0.92 years in Sungai Tekir, Negeri Sembilan were provided with three freshly-prepared snacks (springroll, curry puff or doughnut) each containing one teaspoon or 5 ml of RPO per serving, on separate mornings. On the fourth morning, one serving each of all 3 different snacks was provided together on a plate to every child for consumption and preference for the snacks recorded. The children's habitual vitamin A intakes were assessed by a semi-quantitative food frequency questionnaire (FFQ) and carotenoid retention tests for the prepared snacks were performed by column chromatography. Fifty-four percent of the children did not meet their RNI for vitamin A. Based on acceptance criterion of consuming at least one-half serving of the snacks provided, springroll and curry puff recorded 100% acceptability while doughnut had 82% acceptability. Preference of snack was in the order, springroll (47%) > doughtnut (35%) > curry puff (18%), but a Z-test test for proportions showed no statistical significance. Carotenoid retention tests showed great variation between snacks namely, doughnut (100%) > springroll (84%) > curry puff (45%). The overall findings indicate that the RPO-based snacks are highly acceptable and can be used to improve the dietary intake of provitamin A carotenoids of Malaysian Orang Asli children.

  2. Electron particle transport and turbulence studies in the T-10 tokamak

    NASA Astrophysics Data System (ADS)

    Vershkov, V. A.; Borisov, M. A.; Subbotin, G. F.; Shelukhin, D. A.; Dnestrovskii, Yu. N.; Danilov, A. V.; Cherkasov, S. V.; Gorbunov, E. P.; Sergeev, D. S.; Grashin, S. A.; Krylov, S. V.; Kuleshin, E. O.; Myalton, T. B.; Skosyrev, Yu. V.; Chistiakov, V. V.

    2013-08-01

    The goals of this paper are to compare the results of electron particle transport measurements in ohmic (OH) plasmas by means of a small perturbation technique, high-level gas puff and gas switch off, investigate the phenomenon of ‘density pump out’ during electron cyclotron resonance heating (ECRH) and to correlate density behaviour with turbulence. Two approaches for plasma particle transport studies were compared: the low perturbation technique of periodic puff (δn/ne = 0.3%) and strong density variations (δn/ne < 50%), including density ramp-up by gas puff and ramp-down with gas switch off. The model with constant in time diffusion coefficients and pinch velocities could describe the core density perturbations but failed at the edge. In the case of strong puff three stages were distinguished. Degraded energy confinement and, respectively, low turbulence frequencies were observed during density ramp-up and ramp-down, while enhanced confinement and higher turbulence frequencies were typical for the intermediate stage. Density profile variation during this intermediate phase could be described in the framework of the transport model with constant in time coefficients. The application of ECRH at the density ramp-up phase provided the possibility of postponing the ‘density pump out’. The increase in the low-frequency modes in turbulence spectra was observed at the ‘density pump out’ phase during central ECRH. Although the high- and low-frequency bands of turbulence spectra behaved as trapped electron mode and ion temperature gradient, respectively, they both rotated at the same angular velocity as a rigid body together with magnetohydrodynamic mode m/n = 2/1 and [E × B] plasma rotation.

  3. Detection of 5-hydroxymethylfurfural and furfural in the aerosol of electronic cigarettes.

    PubMed

    Soussy, Sarah; El-Hellani, Ahmad; Baalbaki, Rima; Salman, Rola; Shihadeh, Alan; Saliba, Najat A

    2016-11-01

    The wide availability of sweet flavours has been hypothesised as a factor in the popularity of electronic cigarette (ECIG), especially among youth. Saccharides, which are commonly used to impart a sweet flavour to ECIG liquids, thermally degrade to produce toxic compounds, like aldehydes and furans. This study investigates the formation of furanic compounds in aerosols when ECIG liquid solutions of varying sweetener concentrations are vaped under different power and puff duration. Liquids are prepared by mixing aqueous sucrose, glucose or sorbitol solutions to a 70/30 propylene glycol/glycerin solution. Aerosols are generated and trapped on filter pads using a commercially available ECIG operating at 4.3 and 10.8 W and 4 and 8 s puff duration. Extraction, elimination of matrix interference and quantification are achieved using novel solid phase extraction and gas chromatography tandem mass spectrometry methods (GC-MS). Well-resolved GC peaks of 5-hydroxymethylfurfural (HMF) and furfural (FA) are detected. Both HMF and FA are quantified in the aerosols of sweet-flavoured e-liquids under various vaping conditions. Levels of furan emissions are significantly correlated with electric power and sweetener concentration and not with puff duration. Unlike saccharides, the formation of HMF and FA from a sugar alcohol is negligible. The addition of sweeteners to ECIG liquids exposes ECIG user to furans, a toxic class of compounds. Under certain conditions, the per-puff yield of HMF and FA in ECIG emissions is comparable to values reported for combustible cigarettes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Potential harmful health effects of inhaling nicotine-free shisha-pen vapor: a chemical risk assessment of the main components propylene glycol and glycerol.

    PubMed

    Kienhuis, Anne S; Soeteman-Hernandez, Lya G; Bos, Peter Mj; Cremers, Hans Wjm; Klerx, Walther N; Talhout, Reinskje

    2015-01-01

    A shisha-pen is an electronic cigarette variant that is advertised to mimic the taste of a water pipe, or shisha. The aim of this study was to assess the potential harmful health effects caused by inhaling the vapor of a nicotine-free shisha-pen. Gas chromatography analysis was performed to determine the major components in shisha-pen vapor. Risk assessment was performed using puff volumes of e-cigarettes and "normal" cigarettes and a 1-puff scenario (one-time exposure). The concentrations that reached the airways and lungs after using a shisha-pen were calculated and compared to data from published toxicity studies. The main components in shisha-pen vapor are propylene glycol and glycerol (54%/46%). One puff (50 to 70 mL) results in exposure of propylene glycol and glycerol of 430 to 603 mg/m(3) and 348 to 495 mg/m(3), respectively. These exposure concentrations were higher than the points of departure for airway irritation based on a human study (propylene glycol, mean concentration of 309 mg/m(3)) and a rat study (glycerol, no-observed adverse effect level of 165 mg/m(3)). Already after one puff of the shisha-pen, the concentrations of propylene glycol and glycerol are sufficiently high to potentially cause irritation of the airways. New products such as the shisha-pen should be detected and risks should be assessed to inform regulatory actions aimed at limiting potential harm that may be caused to consumers and protecting young people to take up smoking.

  5. Comparison of Puff Volume With Cigarettes per Day in Predicting Nicotine Uptake Among Daily Smokers.

    PubMed

    Krebs, Nicolle M; Chen, Allshine; Zhu, Junjia; Sun, Dongxiao; Liao, Jason; Stennett, Andrea L; Muscat, Joshua E

    2016-07-01

    The role of inhalation behaviors as predictors of nicotine uptake was examined in the Pennsylvania Adult Smoking Study (2012-2014), a study of 332 adults whose cigarette smoking was measured in a naturalistic environment (e.g., at home) with portable handheld topography devices. Piecewise regression analyses showed that levels of salivary cotinine, trans-3'-hydroxycotinine, and total salivary nicotine metabolites (cotinine + trans-3'-hydroxycotinine) increased linearly up to a level of about 1 pack per day (20 cigarettes per day (CPD)) (P < 0.01). Total daily puff volume (TDPV; in mL) (P < 0.05) and total daily number of puffs (P < 0.05), but not other topographical measures, increased linearly with CPD up to a level of about 1 pack per day. The mean level of cotinine per cigarette did not change above 20 CPD and was 36% lower in heavy smokers (≥20 CPD) than in lighter smokers (<20 CPD) (15.6 ng/mL vs. 24.5 ng/mL, respectively; P < 0.01). Mediation models showed that TDPV accounted for 43%-63% of the association between CPD and nicotine metabolites for smokers of <20 CPD. TDPV was the best predictor of nicotine metabolite levels in light-to-moderate smokers (1-19 CPD). In contrast, neither CPD, total daily number of puffs, nor TDPV predicted nicotine metabolite levels above 20 CPD (up to 40 CPD). Finally, although light smokers are traditionally considered less dependent on nicotine, these findings suggest that they are exposed to more nicotine per cigarette than are heavy smokers due to more frequent, intensive puffing. © The Author 2016. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. DUST AROUND R CORONAE BOREALIS STARS. I. SPITZER/INFRARED SPECTROGRAPH OBSERVATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anibal Garcia-Hernandez, D.; Kameswara Rao, N.; Lambert, David L., E-mail: agarcia@iac.es, E-mail: nkrao@iiap.res.in, E-mail: dll@astro.as.utexas.edu

    2011-09-20

    Spitzer/infrared spectrograph (IRS) spectra from 5 to 37 {mu}m for a complete sample of 31 R Coronae Borealis stars (RCBs) are presented. These spectra are combined with optical and near-infrared photometry of each RCB at maximum light to compile a spectral energy distribution (SED). The SEDs are fitted with blackbody flux distributions and estimates are made of the ratio of the infrared flux from circumstellar dust to the flux emitted by the star. Comparisons for 29 of the 31 stars are made with the Infrared Astronomical Satellite (IRAS) fluxes from three decades earlier: Spitzer and IRAS fluxes at 12 {mu}mmore » and 25 {mu}m are essentially equal for all but a minority of the sample. For this minority, the IRAS to Spitzer flux ratio exceeds a factor of three. The outliers are suggested to be stars where formation of a dust cloud or dust puff is a rare event. A single puff ejected prior to the IRAS observations may have been reobserved by Spitzer as a cooler puff at a greater distance from the RCB. RCBs which experience more frequent optical declines have, in general, a circumstellar environment containing puffs subtending a larger solid angle at the star and a quasi-constant infrared flux. Yet, the estimated subtended solid angles and the blackbody temperatures of the dust show a systematic evolution to lower solid angles and cooler temperatures in the interval between IRAS and Spitzer. Dust emission by these RCBs and those in the LMC is similar in terms of total 24 {mu}m luminosity and [8.0]-[24.0] color index.« less

  7. Electronic Cigarette Nicotine Delivery Can Exceed that of Combustible Cigarettes: A Preliminary Report

    PubMed Central

    Ramôa, Carolina P.; Hiler, Marzena M.; Spindle, Tory R; Lopez, Alexa A.; Karaoghlanian, Nareg; Lipato, Thokozeni; Breland, Alison B.; Shihadeh, Alan; Eissenberg, Thomas

    2016-01-01

    Introduction Electronic cigarettes (ECIGs) aerosolize a liquid that usually contains propylene glycol and/or vegetable glycerin, flavorants, and the dependence-producing drug nicotine in various concentrations. This laboratory study examined the relationship between liquid nicotine concentration on plasma nicotine concentration and puffing behavior in experienced ECIG users. Methods Sixteen ECIG-experienced participants used a 3.3-Volt ECIG battery attached to a 1.5-Ohm dual-coil “cartomizer” loaded with 1 ml of a flavored propylene glycol/vegetable glycerin liquid to complete four sessions, at least 2 days apart, that differed by nicotine concentration (0, 8, 18, or 36 mg/ml). In each session, participants completed two 10-puff ECIG use bouts (30-sec puff interval) separated by 60 minutes. Venous blood was sampled to determine plasma nicotine concentration. Puff duration, volume, and average flow rate were measured. Results Immediately after bout 1, mean plasma nicotine concentration was 5.5 ng/ml (SD=7.7) for 0 mg/ml liquid, with significantly (p<0.05) higher mean concentrations observed for the 8 (mean=17.8 ng/ml, SD=14.6), 18 (mean=25.9 ng/ml, SD=17.5), and 36 mg/ml (mean=30.2 ng/ml; SD=20.0) concentrations; a similar pattern was observed for bout 2. For bout 1, at 36 mg/ml, the mean post- minus pre-bout difference was 24.1 ng/ml (SD=18.3). Puff topography data were consistent with previous results and revealed few reliable differences across conditions. Discussion This study demonstrates a relationship between ECIG liquid nicotine concentration and user plasma nicotine concentration in experienced ECIG users. Nicotine delivery from some ECIGs may exceed that of a combustible cigarette. The rationale for this higher level of nicotine delivery is uncertain. PMID:26324250

  8. Initial puffing behaviors and subjective responses differ between an electronic nicotine delivery system and traditional cigarettes.

    PubMed

    Norton, Kaila J; June, Kristie M; O'Connor, Richard J

    2014-01-01

    Electronic nicotine delivery systems (ENDS) present an emerging issue for tobacco control and data on product use behaviors are limited. Participants (N = 38 enrolled; N = 16 compliant) completed three lab visits over 5 days and were asked to abstain from regular cigarettes for 72 hours in favor of ENDS (Smoke 51 TRIO - 3 piece, First Generation with 11 mg/ml filters). Lab visits included measurement of exhaled carbon monoxide (CO) and salivary cotinine concentration, questionnaire measures of regular cigarette craving after the 72 hour abstinence, and subjective product effects. Participants used a topography device to record puff volume, duration, flow rate, and inter-puff interval. Analyses revealed significant differences across products in puff count, average volume, total volume and inter-puff interval, with ENDS broadly showing a more intensive smoking pattern. Cigarette craving scores dropped significantly after smoking regular cigarettes, but not ENDS (p = .001), and subjective measures showed ENDS rated less favorably. CO boost, after ENDS use, decreased significantly (p < .001), and saliva cotinine significantly dropped between visits 1 and 3 (p < 0.001) after ENDS use relative to after cigarette smoking. For compliant and non-compliant participants, there was an average 82.0% [V1 - 16.1 cpd; V3 - 2.9 cpd] and average 73.9% [V1 - 20.3 cpd; V3 - 5.3 cpd] reduction in regular cigarette use per day during the ENDS trial period, respectively. The ENDS were smoked more intensively than own brand cigarettes, but delivered significantly less nicotineand were less satisfying. These findings have implications for the viability of certain ENDS as alternatives to cigarettes.

  9. Simulation of Tracer Concentration Data in the Brush Creek Drainage Flow Using an Integrated Puff Model.

    NASA Astrophysics Data System (ADS)

    Rao, K. Shankar; Eckman, Richard M.; Hosker, Rayford P., Jr.

    1989-07-01

    During the 1984 ASCOT field study in Brush Creek Valley, two perfluorocarbon tracers were released into the nocturnal drainage flow at two different heights. The resulting surface concentrations were sampled at 90 sites, and vertical concentration profiles at 11 sites. These detailed tracer measurements provide a valuable dataset for developing and testing models of pollutant transport and dispersion in valleys.In this paper, we present the results of Gaussian puff model simulations of the tracer releases in Brush Creek Valley. The model was modified to account for the restricted lateral dispersion in the valley, and for the gross elevation differences between the release site and the receptors. The variable wind fields needed to transport the puffs were obtained by interpolation between wind profiles measured using tethered balloons at five along-valley sites. Direct turbulence measurements were used to estimate diffusion. Subsidence in the valley flow was included for elevated releases.Two test simulations-covering different nights, tracers, and release heights-were performed. The predicted hourly concentrations were compared with observations at 51 ground-level locations. At most sites, the predicted and observed concentrations agree within a factor of 2 to 6. For the elevated release simulation, the observed mean concentration is 40 pL/L, the predicted mean is 21 pL/L, the correlation coefficient between the observed and predicted concentrations is 0.24, and the index of agreement is 0.46. For the surface release simulation, the observed mean is 85 pL/L, and the predicted mean is 73 pL/L. The correlation coefficient is 0.23, and the index of agreement is 0.42. The results suggest that this modified puff model can be used as a practical tool for simulating pollutant transport and dispersion in deep valleys.

  10. Comparison of Puff Volume With Cigarettes per Day in Predicting Nicotine Uptake Among Daily Smokers

    PubMed Central

    Krebs, Nicolle M.; Chen, Allshine; Zhu, Junjia; Sun, Dongxiao; Liao, Jason; Stennett, Andrea L.; Muscat, Joshua E.

    2016-01-01

    Abstract The role of inhalation behaviors as predictors of nicotine uptake was examined in the Pennsylvania Adult Smoking Study (2012–2014), a study of 332 adults whose cigarette smoking was measured in a naturalistic environment (e.g., at home) with portable handheld topography devices. Piecewise regression analyses showed that levels of salivary cotinine, trans-3′-hydroxycotinine, and total salivary nicotine metabolites (cotinine + trans-3′-hydroxycotinine) increased linearly up to a level of about 1 pack per day (20 cigarettes per day (CPD)) (P < 0.01). Total daily puff volume (TDPV; in mL) (P < 0.05) and total daily number of puffs (P < 0.05), but not other topographical measures, increased linearly with CPD up to a level of about 1 pack per day. The mean level of cotinine per cigarette did not change above 20 CPD and was 36% lower in heavy smokers (≥20 CPD) than in lighter smokers (<20 CPD) (15.6 ng/mL vs. 24.5 ng/mL, respectively; P < 0.01). Mediation models showed that TDPV accounted for 43%–63% of the association between CPD and nicotine metabolites for smokers of <20 CPD. TDPV was the best predictor of nicotine metabolite levels in light-to-moderate smokers (1–19 CPD). In contrast, neither CPD, total daily number of puffs, nor TDPV predicted nicotine metabolite levels above 20 CPD (up to 40 CPD). Finally, although light smokers are traditionally considered less dependent on nicotine, these findings suggest that they are exposed to more nicotine per cigarette than are heavy smokers due to more frequent, intensive puffing. PMID:27313218

  11. Self-titration by experienced e-cigarette users: blood nicotine delivery and subjective effects.

    PubMed

    Dawkins, Lynne E; Kimber, Catherine F; Doig, Mira; Feyerabend, Colin; Corcoran, Olivia

    2016-08-01

    Self-titration is well documented in the tobacco literature. The extent to which e-cigarette users (vapers) self-titrate is unknown. This study explored the effects of high and low nicotine strength liquid on puffing topography, nicotine delivery and subjective effects in experienced vapers. Eleven experienced male vapers completed 60 min of ad libitum vaping under low (6 mg/mL) and high (24 mg/mL) nicotine liquid conditions in two separate sessions. Measurements included puffing topography (puff number, puff duration, volume of liquid consumed) and changes in plasma nicotine levels, craving, withdrawal symptoms, self-reported hit, satisfaction and adverse effects. Liquid consumption and puff number were higher and puff duration longer, in the low nicotine strength condition (all ps < 0.01). The mean difference in nicotine boost from baseline in the low condition was 8.59 (7.52) ng/mL, 16.99 (11.72) ng/mL and 22.03 (16.19) ng/mL at 10, 30 and 60 min, respectively. Corresponding values for the high condition were 33.77 (34.88) ng/mL, 35.48 (28.31) ng/mL and 43.57 (34.78) ng/mL (ps < 0.05). There were no statistically significant differences between conditions in self-reported craving, withdrawal symptoms, satisfaction, hit or adverse effects. Vapers engaged in compensatory puffing with lower nicotine strength liquid, doubling their consumption. Whilst compensatory puffing was sufficient to reduce craving and withdrawal discomfort, self-titration was incomplete with significantly higher plasma nicotine levels in the high condition.

  12. Edge Turbulence Imaging in Alcator C-Mod

    NASA Astrophysics Data System (ADS)

    Zweben, Stewart J.

    2001-10-01

    This talk will describe measurements and modeling of the 2-D structure of edge turbulence in Alcator C-Mod. The radial vs. poloidal structure was measured using Gas Puff Imaging (GPI) (R. Maqueda et al, RSI 72, 931 (2001), J. Terry et al, J. Nucl. Materials 290-293, 757 (2001)), in which the visible light emitted by an edge neutral gas puff (generally D or He) is viewed along the local magnetic field by a fast-gated video camera. Strong fluctuations are observed in the gas cloud light emission when the camera is gated at ~2 microsec exposure time per frame. The structure of these fluctuations is highly turbulent with a typical radial and poloidal scale of ≈1 cm, and often with local maxima in the scrape-off layer (i.e. ``blobs"). Video clips and analyses of these images will be presented along with their variation in different plasma regimes. The local time dependence of edge turbulence is measured using high-speed photodiodes viewing the gas puff emission, a scanning Langmuir probe, and also with a Princeton Scientific Instruments ultra-fast framing camera, which can make 2-D images the gas puff at up to 200,000 frames/sec. Probe measurements show that the strong turbulence region moves to the separatrix as the density limit is approached, which may be connected to the density limit (B. LaBombard et al., Phys. Plasmas 8 2107 (2001)). Comparisons of this C-Mod turbulence data will be made with results of simulations from the Drift-Ballooning Mode (DBM) (B.N. Rogers et al, Phys. Rev. Lett. 20 4396 (1998))and Non-local Edge Turbulence (NLET) codes.

  13. Effect of Laser in Situ Keratomileusis on Schiøtz, Goldmann, and Dynamic Contour Tonometric Measurements.

    PubMed

    Sales-Sanz, Marco; Arranz-Marquez, Esther; Piñero, David P; Arruabarrena, Carolina; Mikropoulos, Dimitrios G; Teus, Miguel A

    2016-04-01

    To assess the effect of laser in situ keratomileusis (LASIK) on ocular rigidity and compare its effect on intraocular pressure (IOP) readings with Goldmann applanation tonometry (GAT), Schiøtz indentation tonometry (ST), and dynamic contour tonometry (DCT). Prospective, observational, single-masked study. Eighty-one patients who underwent myopic LASIK and 108 unoperated myopic control patients were included in the study. The IOP was measured using GAT, DCT, and ST. The coefficient of ocular rigidity (Ko) was obtained from the regression analysis of the 3 readings obtained with each weight of the ST. Linear multiple regression analysis was performed with dummy variables to assess the effects of age, central corneal thickness (CCT), and refractive surgery on measured IOP values. Age, CCT, and previous LASIK explained 39.41% of the IOP readings with GAT, 25.31% with DCT, and 3.28% with ST. LASIK caused a mean decrease of -2.51 mm Hg in IOP readings (P=0.000) with GAT, -1.29 mm Hg (P=0.036) with DCT, and no significant change in IOP readings with ST (P=0.299). Significant differences in the Ko were observed between the LASIK and control groups. The Ko values were unrelated to age and CCT in the LASIK and control groups. ST seems to be less affected by previous LASIK procedures. There is a difference in the ocular rigidity between the unoperated and LASIK eyes that is not correlated with the CCT. Therefore, ST seems to measure changes in the biomechanical behavior of corneas that underwent LASIK surgery.

  14. A simplified measurement of pulse wave velocity is not inferior to standard measurement in young adults and children.

    PubMed

    Edgell, Heather; Stickland, Michael K; MacLean, Joanna E

    2016-06-01

    The standard measurement of pulse wave velocity (PWV) is restricted by the need for simultaneous tonometry measurements requiring two technicians and expensive equipment, limiting this technique to well-resourced settings. In this preliminary study, we compared a simplified method of pulse wave detection from the finger and toe to pulse wave detection from the carotid and radial arteries using applanation tonometry in children and young adults. We hypothesized that the simplified method of PWV measurement would strongly correlate with the standard measurement in different age groups and oxygen conditions. Participants included (a) boys and girls aged 8-12 years and (b) men and women aged 18-40 years. Participants rested supine while carotid and radial artery pulse waves were measured using applanation tonometry and finger and toe pulse waves were simultaneously collected using a Finometer Midi and a piezo-electric pulse transducer, respectively. These measurements were repeated under hypoxic conditions. Finger-toe PWV measurements were strongly correlated to carotid-radial PWV in adults (R=0.58; P=0.011), but not in children (R=0.056; P=0.610). Finger-toe PWV was sensitive enough to show increases in PWV with age (P<0.0001) and hypoxia in children (P<0.0001) and adults (P=0.003). These results indicate that the simplified measurement of finger-toe PWV strongly correlates with the standard measurement of carotid-radial PWV in adults, but not in children. However, finger-toe PWV can be used in either population to determine changes with hypoxia.

  15. Emissions from Electronic Cigarettes: Assessing Vapers' Intake of Toxic Compounds, Secondhand Exposures, and the Associated Health Impacts.

    PubMed

    Logue, Jennifer M; Sleiman, Mohamad; Montesinos, V Nahuel; Russell, Marion L; Litter, Marta I; Benowitz, Neal L; Gundel, Lara A; Destaillats, Hugo

    2017-08-15

    E-cigarettes likely represent a lower risk to health than traditional combustion cigarettes, but they are not innocuous. Recently reported emission rates of potentially harmful compounds were used to assess intake and predict health impacts for vapers and bystanders exposed passively. Vapers' toxicant intake was calculated for scenarios in which different e-liquids were used with various vaporizers, battery power settings and vaping regimes. For a high rate of 250 puff day -1 using a typical vaping regime and popular tank devices with battery voltages from 3.8 to 4.8 V, users were predicted to inhale formaldehyde (up to 49 mg day -1 ), acrolein (up to 10 mg day -1 ) and diacetyl (up to 0.5 mg day -1 ), at levels that exceeded U.S. occupational limits. Formaldehyde intake from 100 daily puffs was higher than the amount inhaled by a smoker consuming 10 conventional cigarettes per day. Secondhand exposures were predicted for two typical indoor scenarios: a home and a bar. Contributions from vaping to air pollutant concentrations in the home did not exceed the California OEHHA 8-h reference exposure levels (RELs), except when a high emitting device was used at 4.8 V. In that extreme scenario, the contributions from vaping amounted to as much as 12 μg m -3 formaldehyde and 2.6 μg m -3 acrolein. Pollutant concentrations in bars were modeled using indoor volumes, air exchange rates and the number of hourly users reported in the literature for U.S. bars in which smoking was allowed. Predicted contributions to indoor air levels were higher than those in the residential scenario. Formaldehyde (on average 135 μg m -3 ) and acrolein (28 μg m -3 ) exceeded the acute 1-h exposure REL for the highest emitting vaporizer/voltage combination. Predictions for these compounds also exceeded the 8-h REL in several bars when less intense vaping conditions were considered. Benzene concentrations in a few bars approached the 8-h REL, and diacetyl levels were close to the lower limit for occupational exposures. The integrated health damage from passive vaping was derived by computing disability-adjusted life years (DALYs) lost due to exposure to secondhand vapor. Acrolein was the dominant contributor to the aggregate harm. DALYs for the various device/voltage combinations were lower than-or comparable to-those estimated for exposures to secondhand and thirdhand tobacco smoke.

  16. Keep Your Vision Healthy: Learn About Comprehensive Dilated Eye Exams

    MedlinePlus

    ... risk for glaucoma, age-related macular degeneration, and diabetic retinopathy—the most common cause of vision loss from ... to these areas may be a sign of diabetic retinopathy, glaucoma, or age-related macular degeneration. Tonometry measures ...

  17. The Icare HOME (TA022) Study: Performance of an Intraocular Pressure Measuring Device for Self-Tonometry by Glaucoma Patients.

    PubMed

    Mudie, Lucy I; LaBarre, Sophie; Varadaraj, Varshini; Karakus, Sezen; Onnela, Jouni; Munoz, Beatriz; Friedman, David S

    2016-08-01

    To evaluate the Icare HOME (TA022) device (Icare Oy, Vanda, Finland) for use by glaucoma patients for self-tonometry. Prospective performance evaluation of a medical device. One hundred eighty-nine participants with glaucoma or suspected glaucoma were recruited from the Wilmer Eye Institute, Baltimore, Maryland, between July 2014 and April 2015. Participants had standardized training and had to be able use the Icare HOME device independently. Subjects also had to be able to obtain the first intraocular pressure (IOP) measurement within 5 mmHg of Goldmann applanation tonometry (GAT). Those certified obtained 3 IOP measures using the HOME device, and these were compared with Icare TA01i and GAT IOP measurements. The agreement between Icare HOME and reference tonometers was used to assess precision. The intraclass correlation coefficient was used to assess within-patient reliability for the HOME device. Eighteen of 189 recruited patients were ineligible to take part in the study. Forty-four of 171 patients (25.7%) started but failed to complete the study: 7 stopped because of time concerns, 10 of 171 patients (6%) stopped because of difficulty using the device during certification, and 27 of 171 patients (16%) failed to be certified based on IOP. The HOME and GAT measurements agreed within 5 mmHg in 116 of 127 participants (91.3%); 2 participants (1.6%) had a difference of more than 7 mmHg. The mean difference between the Icare HOME and GAT measurements was -0.33 mmHg (standard deviation, 3.11 mmHg). The overall intraclass correlation coefficient for the HOME device was 0.92 (95% confidence interval, 0.89-0.95). Not all participants could learn how to use the Icare HOME device, but for those who could, most were able to obtain measurements similar to those obtained by GAT. The Icare HOME device is safe and reliable for self-tonometry, but nearly 1 in 6 individuals may fail to certify in use of the device based on large differences in IOP when comparing GAT with the Icare HOME measurements. The device has the potential to address an unmet need by providing more frequent IOP measurements in a patient's day to day life. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  18. Cigarette filter ventilation is a defective design because of misleading taste, bigger puffs, and blocked vents.

    PubMed

    Kozlowski, L T; O'Connor, R J

    2002-03-01

    To review tobacco industry documents on filter ventilation in light of published studies and to explore the role of filter ventilation in the design of cigarettes that deliver higher smoke yields to smokers than would be expected from standard machine smoked tests (Federal Trade Commission (FTC), International Organization for Standardization (ISO)). Searched from November 1999 to November 2000 internet databases of industry documents (www.pmdocs.com, www.rjrtdocs.com, www.lorillarddocs.com, www.bw.aalatg.com, www.cdc.gov/tobacco/industrydocs, www.tobaccodocuments.org, www.tobaccopapers.org, www.hlth.gov.bc.ca/Guildford, www.cctc.ca/ncth/Guildford, www.cctc.ca/ncth/Guildford2) for documents related to filter ventilation. Documents found dated from 1955 through 1994. Those documents judged to contain the most relevant information or data on filter ventilation related to cigarette taste and compensatory smoking, while also trying to avoid redundancy from various documents deriving from the same underlying data. Filter ventilation is a crucial design feature creating three main problems for lower tar cigarettes as measured by official smoking machine testing. Firstly, it misleadingly makes cigarettes taste lighter and milder, and, therefore, they appear less dangerous to smokers. Secondly, it promotes compensation mainly by facilitating the taking of larger puffs. Thirdly, for very heavily ventilated cigarettes (that is, > 65% filter air dilution), behavioural blocking of vents with lips or fingers is an additional contributor to compensatory smoking. These three effects are found in industry research as well as published research. Filter ventilation is a dangerous, defective technology that should be abandoned in less hazardous nicotine delivery systems. Health interested groups should test cigarettes in a way that reflects compensatory smoking. Lower tar (vented filter) cigarettes should be actively countermarketed.

  19. Silver acetate interactions with nicotine and non-nicotine smoke components.

    PubMed

    Rose, Jed E; Behm, Frédérique M; Murugesan, Thangaraju; McClernon, F Joseph

    2010-12-01

    Oral topical silver-containing formulations were marketed in the 1970s and 1980s as smoking deterrents, based on the finding that when using such formulations, an unpleasant taste occurs upon smoking. This approach has not been widely adopted, however, in part because of a lack of efficacy data. The advent of new pharmacologic treatments for smoking cessation renews the possibility that such a taste aversion approach may be a useful adjunct to smoking cessation treatment. This study explored the basic mechanistic question of whether topical oral silver acetate solution interacts with nicotine as opposed to non-nicotine smoke constituents. We recruited 20 smoking volunteers to rate nicotine-containing or denicotinized cigarettes, as well as the Nicotrol nicotine vapor inhaler and sham (air) puffs. In two sessions, subjects rated the sensory and hedonic qualities of puffs after rinsing their mouths with either silver acetate solution or deionized water (placebo). Silver acetate relative to placebo solution substantially reduced liking and satisfaction ratings for the usual brand and denicotinized cigarettes; in contrast, for the nicotine inhaler these ratings were unaffected by the silver-based treatment. These results support the conclusion that silver acetate not only renders the taste of cigarette smoke less appealing, but also that the compound appears to interact selectively with non-nicotine smoke constituents. Moreover, these data suggest silver acetate would be compatible with buccal nicotine delivery systems (e.g., nicotine lozenge or gum). Combined use of taste aversion with nicotine replacement therapy could provide the smoker with additional assistance to resist relapse. Further exploration is warranted of the use of silver-based preparations as a short-term adjunct to smoking cessation treatment. PsycINFO Database Record (c) 2010 APA, all rights reserved.

  20. Evaluation of regional and local atmospheric dispersion models for the analysis of traffic-related air pollution in urban areas

    NASA Astrophysics Data System (ADS)

    Fallah-Shorshani, Masoud; Shekarrizfard, Maryam; Hatzopoulou, Marianne

    2017-10-01

    Dispersion of road transport emissions in urban metropolitan areas is typically simulated using Gaussian models that ignore the turbulence and drag induced by buildings, which are especially relevant for areas with dense downtown cores. To consider the effect of buildings, street canyon models are used but often at the level of single urban corridors and small road networks. In this paper, we compare and validate two dispersion models with widely varying algorithms, across a modelling domain consisting of the City of Montreal, Canada accounting for emissions of more 40,000 roads. The first dispersion model is based on flow decomposition into the urban canopy sub-flow as well as overlying airflow. It takes into account the specific height and geometry of buildings along each road. The second model is a Gaussian puff dispersion model, which handles complex terrain and incorporates three-dimensional meteorology, but accounts for buildings only through variations in the initial vertical mixing coefficient. Validation against surface observations indicated that both models under-predicted measured concentrations. Average weekly exposure surfaces derived from both models were found to be reasonably correlated (r = 0.8) although the Gaussian dispersion model tended to underestimate concentrations around the roadways compared to the street canyon model. In addition, both models were used to estimate exposures of a representative sample of the Montreal population composed of 1319 individuals. Large differences were noted whereby exposures derived from the Gaussian puff model were significantly lower than exposures derived from the street canyon model, an expected result considering the concentration of population around roadways. These differences have large implications for the analyses of health effects associated with NO2 exposure.

  1. Extreme testing of undiluted e-cigarette aerosol in vitro using an Ames air-agar-interface technique.

    PubMed

    Thorne, D; Hollings, M; Seymour, A; Adamson, J; Dalrymple, A; Ballantyne, M; Gaca, M

    2018-04-01

    There is a growing consensus that e-cigarettes hold the potential for reducing the harm associated with cigarette smoking. Recently published studies have reported in vitro testing of e-cigarettes, demonstrating reduced toxicological and biological effects. Few studies however have reported the use of e-cigarettes under extreme testing conditions. To assess the full mutagenic potential of a commercially available electronic-cigarette (Vype ePen), this study investigated the delivery of aerosol under extreme conditions, using a scaled-down 35 mm plate Ames bacterial reverse mutagenicity assay. S. typhimurium strains TA98, TA100, TA97, TA104 and E. coli WP2 uvrA pKM101 with or without metabolic activation (S9), were employed. Using a modified Vitrocell VC 10 exposure system 0, 180, 360, 540, 720 or 900 puffs of undiluted e-cigarette aerosol was generated and delivered to bacterial cultures aligned to reported human consumption data. The results demonstrate that no mutagenic activity was observed in any strain under any test condition even when exposed to 900 puffs of undiluted e-cigarette aerosols +/- S9. Positive control responses were observed in all strains +/- S9. Nicotine assessments demonstrated an increased and consistent aerosol delivery, with calculated maximum doses of ∼1 mg/mL delivery of nicotine. These data demonstrate the validity of this unique testing approach and adds further information to the growing weight of evidence that e-cigarettes offer substantially reduced exposure when compared to conventional cigarette smoke. For future in vitro assessments of next generation tobacco and nicotine products, the generation, delivery and testing of undiluted aerosols can now be considered. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Antioxidant responses following active and passive smoking of tobacco and electronic cigarettes.

    PubMed

    Poulianiti, Konstantina; Karatzaferi, Christina; Flouris, Andreas D; Fatouros, Ioannis G; Koutedakis, Yiannis; Jamurtas, Athanasios Z

    2016-07-01

    It has been indicated that acute active and passive tobacco cigarette smoking may cause changes on redox status balance that may result in significant pathologies. However, no study has evaluated the effects of active and passive e-cigarette smoking on redox status of consumers. To examine the acute effects of active and passive e-cigarette and tobacco cigarette smoking on selected redox status markers. Using a randomized single-blind crossover design, 30 participants (15 smokers and 15 nonsmokers) were exposed to three different experimental conditions. Smokers underwent a control session, an active tobacco cigarette smoking session (smoked 2 cigarettes within 30-min) and an active e-cigarette smoking session (smoked a pre-determined number of puffs within 30-min using a liquid with 11 ng/ml nicotine). Similarly, nonsmokers underwent a control session, a passive tobacco cigarette smoking session (exposure of 1 h to 23 ± 1 ppm of CO in a 60 m(3) environmental chamber) and a passive e-cigarette smoking session (exposure of 1 h to air enriched with pre- determined number of puffs in a 60 m(3) environmental chamber). Total antioxidant capacity (TAC), catalase activity (CAT) and reduced glutathione (GSH) were assessed in participants' blood prior to, immediately after, and 1-h post-exposure. TAC, CAT and GSH remained similar to baseline levels immediately after and 1-h-post exposure (p > 0.05) in all trials. Tobacco and e-cigarette smoking exposure do not acutely alter the response of the antioxidant system, neither under active nor passive smoking conditions. Overall, there is not distinction between tobacco and e-cigarette active and passive smoking effects on specific redox status indices.

  3. Operation greenhouse. Scientific director`s report of atomic weapon tests at Eniwetok, 1951. Annex 8.1. Blast effects on aircraft in flight. Nuclear explosion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wayne, J.C.; Lehmkuhl, J.C.

    1951-10-01

    The primary objective of this report is to present data concerning the structural and aerodynamic loads as measured on various types of aircraft, in flight, in the vicinity of an atomic explosion. A secondary objective is to describe the instrumentation (installation, calibration, and operation) in order to provide for the future planning and conduct of similar tests. The data presented herein were obtained on Dog, Easy, and George shots of Operation Greenhouse. The airplanes used to collect these data were B-17`s, T-33`s, B-50D`s and one XB-47. These instrumented airplanes were arrayed at preassigned locations in the air space above themore » explosions. A total of approximately 250 channels of information were obtained which essentially consisted in wing bending, torsion, and shear at the root, mid-span, and outer panel; horizontal stabilizer bending at the root; normal accelerations at the nose, c.g., and tail; aerodynamic pressures at various locations on the airplanes; and temperatures experienced by various critical components of the airplane. The positions of the airplanes at the time of shock arrival were accurately determined by means of radar tracking. The measured data were correlated by means of time signals, every second, from a land based radio transmitter station, and with reference to time zero, by means of a photoelectric cell. The recorded data show that the loads produced by the shock wave were in general accord with theory. The loading experienced by an airplane while passing through the `puff` of the atomic cloud is shown to be considerably higher than that caused by the shock wave. For this reason the penetration of the puff should be avoided even by `sampling` drones.« less

  4. Effects of alternative reinforcer and craving on the choice to smoke cigarettes in the laboratory.

    PubMed

    Bisaga, Adam; Padilla, Margarita; Garawi, Fatima; Sullivan, Maria A; Haney, Margaret

    2007-01-01

    We examined to what extent craving for cigarettes and the magnitude of an alternative monetary reinforcer were predictors of the choice to smoke in the human laboratory. Twelve non-treatment-seeking nicotine-dependent volunteers participated in a series of outpatient sessions during which they had repeated opportunities to select between three puffs of a cigarette and a variety of monetary alternatives ($0.50-3), responding under a progressive-ratio schedule. Level of cigarette craving was measured at baseline and between each choice opportunity. The probability of choosing a cigarette decreased significantly with the increase in the magnitude of the alternative reinforcer. Baseline level of craving did not significantly alter the probability of choosing a cigarette, but a craving component related to the anticipation of positive effects from smoking, assessed repeatedly between choice opportunities, was predictive of the choice to smoke. These results demonstrate that the cigarette puff self-administration procedure is sensitive to environmental manipulations and cigarette puff choice can be modified by the availability of an alternative reinforcer. This paradigm models the motivational component associated with choice to smoke and could be used to evaluate the effects of pharmacological and behavioral interventions to decrease cigarette smoking.

  5. An ambusher's arsenal: chemical crypsis in the puff adder (Bitis arietans)

    PubMed Central

    Miller, Ashadee Kay; Maritz, Bryan; McKay, Shannon; Glaudas, Xavier; Alexander, Graham J.

    2015-01-01

    Ambush foragers use a hunting strategy that places them at risk of predation by both visual and olfaction-oriented predators. Resulting selective pressures have driven the evolution of impressive visual crypsis in many ambushing species, and may have led to the development of chemical crypsis. However, unlike for visual crypsis, few studies have attempted to demonstrate chemical crypsis. Field observations of puff adders (Bitis arietans) going undetected by several scent-orientated predator and prey species led us to investigate chemical crypsis in this ambushing species. We trained dogs (Canis familiaris) and meerkats (Suricata suricatta) to test whether a canid and a herpestid predator could detect B. arietans using olfaction. We also tested for chemical crypsis in five species of active foraging snakes, predicted to be easily detectable. Dogs and meerkats unambiguously indicated active foraging species, but failed to correctly indicate puff adder, confirming that B. arietans employs chemical crypsis. This is the first demonstration of chemical crypsis anti-predatory behaviour, though the phenomenon may be widespread among ambushers, especially those that experience high mortality rates owing to predation. Our study provides additional evidence for the existence of an ongoing chemically mediated arms race between predator and prey species. PMID:26674950

  6. Effect of the axial magnetic field on a metallic gas-puff pinch implosion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rousskikh, A. G.; Zhigalin, A. S.; Frolova, V.

    2016-06-15

    The effect of an axial magnetic field B{sub z} on an imploding metallic gas-puff Z-pinch was studied using 2D time-gated visible self-emission imaging. Experiments were performed on the IMRI-5 generator (450 kA, 450 ns). The ambient field B{sub z} was varied from 0.15 to 1.35 T. It was found that the initial density profile of a metallic gas-puff Z-pinch can be approximated by a power law. Time-gated images showed that the magneto-Rayleigh–Taylor instabilities were suppressed during the run-in phase both without axial magnetic field and with axial magnetic field. Helical instability structures were detected during the stagnation phase for B{sub z} < 1.1 T. For B{submore » z} = 1.35 T, the pinch plasma boundary was observed to be stable in both run-in and stagnation phases. When a magnetic field of 0.3 T was applied to the pinch, the soft x-ray energy was about twice that generated without axial magnetic field, mostly due to longer dwell time at stagnation.« less

  7. A laboratory-based evaluation of exercise plus contingency management for reducing cigarette smoking.

    PubMed

    Kurti, Allison N; Dallery, Jesse

    2014-11-01

    Both contingency management (CM) and exercise have shown promise as smoking cessation treatments, but their combined effects have not been evaluated. The present study evaluated whether CM (in which motivational incentives are provided for abstinence) plus exercise reduced smoking more than either component alone. In a within-subjects design, 20 smokers were exposed to exercise plus CM, exercise plus CM-control (non-contingent incentives), inactivity plus CM, and inactivity plus CM-control. CM increased latencies to smoke and decreased total puffs (Mdns = 39.6 min and .8 puffs, respectively) relative to CM-control (Mdns = 2.5 min and 12.8 puffs). Exercise decreased craving relative to baseline for craving based on both the pleasurable consequences of smoking (D=-10.7 on a 100-point visual analog scale) and anticipated relief from withdrawal (D=-5.9), whereas inactivity increased both components of craving (Ds=7.6 and 3.5). Exercise had no effect on smoking or a measure of temporal discounting. Although exercise decreased craving, it did not affect smoking behavior. Exercise plus CM was not more effective than CM alone. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Probability density function of a puff dispersing from the wall of a turbulent channel

    NASA Astrophysics Data System (ADS)

    Nguyen, Quoc; Papavassiliou, Dimitrios

    2015-11-01

    Study of dispersion of passive contaminants in turbulence has proved to be helpful in understanding fundamental heat and mass transfer phenomena. Many simulation and experimental works have been carried out to locate and track motions of scalar markers in a flow. One method is to combine Direct Numerical Simulation (DNS) and Lagrangian Scalar Tracking (LST) to record locations of markers. While this has proved to be useful, high computational cost remains a concern. In this study, we develop a model that could reproduce results obtained by DNS and LST for turbulent flow. Puffs of markers with different Schmidt numbers were released into a flow field at a frictional Reynolds number of 150. The point of release was at the channel wall, so that both diffusion and convection contribute to the puff dispersion pattern, defining different stages of dispersion. Based on outputs from DNS and LST, we seek the most suitable and feasible probability density function (PDF) that represents distribution of markers in the flow field. The PDF would play a significant role in predicting heat and mass transfer in wall turbulence, and would prove to be helpful where DNS and LST are not always available.

  9. Smoking Behavior and Smoke Constituents from Cigarillos and Little Cigars

    PubMed Central

    Koszowski, Bartosz; Rosenberry, Zachary R.; Yi, Daniel; Stewart, Sean; Pickworth, Wallace B.

    2017-01-01

    Objective Although most cigarillos and little cigars smokers also smoke cigarettes (dual use), there are few studies comparing toxicant exposure and smoking behavior in cigars and cigarettes. Methods Two groups of dual users smoked their usual brand of cigarette and either a Winchester unflavored little cigar (N = 21) or a Black & Mild cigarillo (N = 23). Acute exposure of nicotine and exhaled carbon monoxide (CO) and puffing topography parameters were collected. Individual cigar puffing data were used to machine-replicate smoking for analysis of volatile organic compounds (VOC) and semi-volatile organic compounds (SVOC) in mainstream smoke. Results There were significant differences in puff topography, plasma nicotine and exhaled CO after cigarettes, little cigars, and cigarillos. Puff topography differences between cigarillos and cigarettes were due to the difference in the size of the article. Mainstream cigar and cigarette smoke was qualitatively similar; the yield was dependent on the smoking behavior. When smoke yield was adjusted for weight of tobacco burned or puff volume, exposure differences decreased. Conclusions There is a wide range of delivery of both SVOC and VOC components of cigar and cigarillo smoke. The difference in exposure is largely dependent on the article size and the amount consumed. PMID:28944278

  10. An ambusher's arsenal: chemical crypsis in the puff adder (Bitis arietans).

    PubMed

    Miller, Ashadee Kay; Maritz, Bryan; McKay, Shannon; Glaudas, Xavier; Alexander, Graham J

    2015-12-22

    Ambush foragers use a hunting strategy that places them at risk of predation by both visual and olfaction-oriented predators. Resulting selective pressures have driven the evolution of impressive visual crypsis in many ambushing species, and may have led to the development of chemical crypsis. However, unlike for visual crypsis, few studies have attempted to demonstrate chemical crypsis. Field observations of puff adders (Bitis arietans) going undetected by several scent-orientated predator and prey species led us to investigate chemical crypsis in this ambushing species. We trained dogs (Canis familiaris) and meerkats (Suricata suricatta) to test whether a canid and a herpestid predator could detect B. arietans using olfaction. We also tested for chemical crypsis in five species of active foraging snakes, predicted to be easily detectable. Dogs and meerkats unambiguously indicated active foraging species, but failed to correctly indicate puff adder, confirming that B. arietans employs chemical crypsis. This is the first demonstration of chemical crypsis anti-predatory behaviour, though the phenomenon may be widespread among ambushers, especially those that experience high mortality rates owing to predation. Our study provides additional evidence for the existence of an ongoing chemically mediated arms race between predator and prey species. © 2015 The Author(s).

  11. Assessment of nicotine concentration in electronic nicotine delivery system (ENDS) liquids and precision of dosing to aerosol.

    PubMed

    Kosmider, Leon; Sobczak, Andrzej; Szołtysek-Bołdys, Izabela; Prokopowicz, Adam; Skórka, Agnieszka; Abdulafeez, Oluyadi; Koszowski, Bartosz

    2015-01-01

    Global use of electronic nicotine delivery systems (ENDS; also called electronic cigarettes, e-cigarettes) has increased dramatically in recent years. However, due to the limited safety studies and growing concerns on the potential toxicity from long term use of ENDS, many national and international governments have employed regulatory measures to curtail its use. One of the most significant challenges regulators of ENDS encounter is the lack of quality standards to assess ENDS, e-liquid (solution used with ENDS which contain nicotine--a highly toxic and addictive substance), and amount of nicotine delivery to aerosol during ENDS use. Aims of the study were to (1) measure and compare nicotine concentration in e-liquids to values reported by manufacturers on packaging labels; (2) assess the precision of nicotine delivery from tank during aerosol formation. Methods: Nine popular Polish e-liquids (based on the market share data from October 2014) were purchased for the study. The labelled nicotine concentration for the selected e-liquids ranged between 11-25 mg/mL. All e-liquids were aerosolized in the laboratory using a smoking simulation machine (Palaczbot). Each e-liquid was aerosolized in a series of 6 consecutive bouts. A single bout consisted of 15 puffs with the following puff topography: 65 mL puff volume, 2.8 sec. puff duration, and 19 sec. interpuff interval. A total of 90 puffs were generated from each e-liquid. Nicotine content in the e-liquids and the aerosol generated were determined by gas chromatography with thermionic sensitive detection (GC-TSD). For seven of nine analyzed e-liquids, the difference between measured and manufacturer labeled nicotine concentration was less than 10%. Nicotine dose in aerosol per bout ranged between 0.77-1.49 mg (equivalent to one-half the nicotine a smoker inhales from a single combustible cigarette). Our analysis showed the high consistency between the labeled and measured nicotine concentration for popular on the Polish market ENDS e-liquids. Also, our analysis demonstrates that the risk for nicotine overdose is likely minimal when ENDS are used in a similar manner as a combustible cigarette. However, due to the toxicity risk nicotine poses regulatory measures focused on safety and quality of e-liquids should continually be exercised.

  12. Assessment of tobacco heating product THP1.0. Part 4: Characterisation of indoor air quality and odour.

    PubMed

    Forster, Mark; McAughey, John; Prasad, Krishna; Mavropoulou, Eleni; Proctor, Christopher

    2018-03-01

    The tobacco heating product THP1.0, which heats but does not burn tobacco, was tested as part of a modified-risk tobacco product assessment framework for its impacts on indoor air quality and residual tobacco smoke odour. THP1.0 heats the tobacco to less than 240 °C ± 5 °C during puffs. An environmentally controlled room was used to simulate ventilation conditions corresponding to residential, office and hospitality environments. An analysis of known tobacco smoke constituents, included CO, CO 2 , NO, NO 2 , nicotine, glycerol, 3-ethenyl pyridine, sixteen polycyclic aromatic hydrocarbons, eight volatile organic compounds, four carbonyls, four tobacco-specific nitrosamines and total aerosol particulate matter. Significant emissions reductions in comparison to conventional cigarettes were measured for THP1.0. Levels of nicotine, acetaldehyde, formaldehyde and particulate matter emitted from THP1.0 exceeded ambient air measurements, but were more than 90% reduced relative to cigarette smoke emissions within the laboratory conditions defined Residual tobacco smoke odour was assessed by trained sensory panels after exposure of cloth, hair and skin to both mainstream and environmental emissions from the test products. Residual tobacco smoke odour was significantly lower from THP1.0 than from a conventional cigarette. These data show that using THP1.0 has the potential to result in considerably reduced environmental emissions that affect indoor air quality relative to conventional cigarettes. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  13. A Experimental Study of the Growth of Laser Spark and Electric Spark Ignited Flame Kernels.

    NASA Astrophysics Data System (ADS)

    Ho, Chi Ming

    1995-01-01

    Better ignition sources are constantly in demand for enhancing the spark ignition in practical applications such as automotive and liquid rocket engines. In response to this practical challenge, the present experimental study was conducted with the major objective to obtain a better understanding on how spark formation and hence spark characteristics affect the flame kernel growth. Two laser sparks and one electric spark were studied in air, propane-air, propane -air-nitrogen, methane-air, and methane-oxygen mixtures that were initially at ambient pressure and temperature. The growth of the kernels was monitored by imaging the kernels with shadowgraph systems, and by imaging the planar laser -induced fluorescence of the hydroxyl radicals inside the kernels. Characteristic dimensions and kernel structures were obtained from these images. Since different energy transfer mechanisms are involved in the formation of a laser spark as compared to that of an electric spark; a laser spark is insensitive to changes in mixture ratio and mixture type, while an electric spark is sensitive to changes in both. The detailed structures of the kernels in air and propane-air mixtures primarily depend on the spark characteristics. But the combustion heat released rapidly in methane-oxygen mixtures significantly modifies the kernel structure. Uneven spark energy distribution causes remarkably asymmetric kernel structure. The breakdown energy of a spark creates a blast wave that shows good agreement with the numerical point blast solution, and a succeeding complex spark-induced flow that agrees reasonably well with a simple puff model. The transient growth rates of the propane-air, propane-air -nitrogen, and methane-air flame kernels can be interpreted in terms of spark effects, flame stretch, and preferential diffusion. For a given mixture, a spark with higher breakdown energy produces a greater and longer-lasting enhancing effect on the kernel growth rate. By comparing the growth rates of the appropriate mixtures, the positive and negative effects of preferential diffusion and flame stretch on the developing flame are clearly demonstrated.

  14. Extremely rare collapse and build-up of turbulence in stochastic models of transitional wall flows.

    PubMed

    Rolland, Joran

    2018-02-01

    This paper presents a numerical and theoretical study of multistability in two stochastic models of transitional wall flows. An algorithm dedicated to the computation of rare events is adapted on these two stochastic models. The main focus is placed on a stochastic partial differential equation model proposed by Barkley. Three types of events are computed in a systematic and reproducible manner: (i) the collapse of isolated puffs and domains initially containing their steady turbulent fraction; (ii) the puff splitting; (iii) the build-up of turbulence from the laminar base flow under a noise perturbation of vanishing variance. For build-up events, an extreme realization of the vanishing variance noise pushes the state from the laminar base flow to the most probable germ of turbulence which in turn develops into a full blown puff. For collapse events, the Reynolds number and length ranges of the two regimes of collapse of laminar-turbulent pipes, independent collapse or global collapse of puffs, is determined. The mean first passage time before each event is then systematically computed as a function of the Reynolds number r and pipe length L in the laminar-turbulent coexistence range of Reynolds number. In the case of isolated puffs, the faster-than-linear growth with Reynolds number of the logarithm of mean first passage time T before collapse is separated in two. One finds that ln(T)=A_{p}r-B_{p}, with A_{p} and B_{p} positive. Moreover, A_{p} and B_{p} are affine in the spatial integral of turbulence intensity of the puff, with the same slope. In the case of pipes initially containing the steady turbulent fraction, the length L and Reynolds number r dependence of the mean first passage time T before collapse is also separated. The author finds that T≍exp[L(Ar-B)] with A and B positive. The length and Reynolds number dependence of T are then discussed in view of the large deviations theoretical approaches of the study of mean first passage times and multistability, where ln(T) in the limit of small variance noise is studied. Two points of view, local noise of small variance and large length, can be used to discuss the exponential dependence in L of T. In particular, it is shown how a T≍exp[L(A^{'}R-B^{'})] can be derived in a conceptual two degrees of freedom model of a transitional wall flow proposed by Dauchot and Manneville. This is done by identifying a quasipotential in low variance noise, large length limit. This pinpoints the physical effects controlling collapse and build-up trajectories and corresponding passage times with an emphasis on the saddle points between laminar and turbulent states. This analytical analysis also shows that these effects lead to the asymmetric probability density function of kinetic energy of turbulence.

  15. Extremely rare collapse and build-up of turbulence in stochastic models of transitional wall flows

    NASA Astrophysics Data System (ADS)

    Rolland, Joran

    2018-02-01

    This paper presents a numerical and theoretical study of multistability in two stochastic models of transitional wall flows. An algorithm dedicated to the computation of rare events is adapted on these two stochastic models. The main focus is placed on a stochastic partial differential equation model proposed by Barkley. Three types of events are computed in a systematic and reproducible manner: (i) the collapse of isolated puffs and domains initially containing their steady turbulent fraction; (ii) the puff splitting; (iii) the build-up of turbulence from the laminar base flow under a noise perturbation of vanishing variance. For build-up events, an extreme realization of the vanishing variance noise pushes the state from the laminar base flow to the most probable germ of turbulence which in turn develops into a full blown puff. For collapse events, the Reynolds number and length ranges of the two regimes of collapse of laminar-turbulent pipes, independent collapse or global collapse of puffs, is determined. The mean first passage time before each event is then systematically computed as a function of the Reynolds number r and pipe length L in the laminar-turbulent coexistence range of Reynolds number. In the case of isolated puffs, the faster-than-linear growth with Reynolds number of the logarithm of mean first passage time T before collapse is separated in two. One finds that ln(T ) =Apr -Bp , with Ap and Bp positive. Moreover, Ap and Bp are affine in the spatial integral of turbulence intensity of the puff, with the same slope. In the case of pipes initially containing the steady turbulent fraction, the length L and Reynolds number r dependence of the mean first passage time T before collapse is also separated. The author finds that T ≍exp[L (A r -B )] with A and B positive. The length and Reynolds number dependence of T are then discussed in view of the large deviations theoretical approaches of the study of mean first passage times and multistability, where ln(T ) in the limit of small variance noise is studied. Two points of view, local noise of small variance and large length, can be used to discuss the exponential dependence in L of T . In particular, it is shown how a T ≍exp[L (A'R -B') ] can be derived in a conceptual two degrees of freedom model of a transitional wall flow proposed by Dauchot and Manneville. This is done by identifying a quasipotential in low variance noise, large length limit. This pinpoints the physical effects controlling collapse and build-up trajectories and corresponding passage times with an emphasis on the saddle points between laminar and turbulent states. This analytical analysis also shows that these effects lead to the asymmetric probability density function of kinetic energy of turbulence.

  16. Prevention of Blindness: Chronic Glaucoma

    ERIC Educational Resources Information Center

    Richardson, Kenneth T.

    1970-01-01

    An evaluation of present screening procedures for chronic open-angle glaucoma includes suggestions for improvement: greater distribution of screening and education, conversion from monophasic to multiphasic screen, and examination of visual fields, optic nerve, and medical history in addition to the tonometry currently done. (KW)

  17. Impaired delay eyeblink conditioning in amnesic Korsakoff's patients and recovered alcoholics.

    PubMed

    McGlinchey-Berroth, R; Cermak, L S; Carrillo, M C; Armfield, S; Gabrieli, J D; Disterhoft, J F

    1995-10-01

    The performance of amnesic Korsakoff patients in delay eyeblink classical conditioning was compared with that of recovered chronic alcoholic subjects and healthy normal control subjects. Normal control subjects exhibited acquisition of conditioned responses (CRs) to a previously neutral, conditioned tone stimulus (CS) following repeated pairings with an unconditioned air-puff stimulus, and demonstrated extinction of CRs when the CS was subsequently presented alone. Both amnesic Korsakoff patients and recovered chronic alcoholic subjects demonstrated an impairment in their ability to acquire CRs. These results indicate that the preservation of delay eyeblink conditioning in amnesia must depend on the underlying neuropathology of the amnesic syndrome. It is known that patients with amnesia caused by medial temporal lobe pathology have preserved conditioning. We have now demonstrated that patients with amnesia caused by Korsakoff's syndrome, as well as recovered chronic alcoholic subjects, have impaired conditioning. This impairment is most likely caused by cerebellar deterioration resulting from years of alcohol abuse.

  18. Recommended operating procedure No. 51: Glass source assessment sampling system (glass SASS). Final report, Jul 90-Jan 91

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grote, R.A.

    1991-05-01

    The report is a recommended operating procedure (ROP), prepared for use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The method described is applicable to the stack sampling of flue gas from a rotary kiln and to associated equipment of AEERL's Combustion Research Branch. It has been the standard method of sampling kiln flue gas due to the transient nature of the puff development and its capability to sample the maximum volume over the shortest time period. ROPs describe non-routine or experimental research operations where some judgment in application may be warranted. ROPs may notmore » be applicable to activities conducted by other research groups, and should not be used in place of standard operating procedures. Use of ROPs must be accompanied by an understanding of the purpose and scope. Questions should be directed to the author.« less

  19. Volcanic ash plume identification using polarization lidar: Augustine eruption, Alaska

    USGS Publications Warehouse

    Sassen, Kenneth; Zhu, Jiang; Webley, Peter W.; Dean, K.; Cobb, Patrick

    2007-01-01

    During mid January to early February 2006, a series of explosive eruptions occurred at the Augustine volcanic island off the southern coast of Alaska. By early February a plume of volcanic ash was transported northward into the interior of Alaska. Satellite imagery and Puff volcanic ash transport model predictions confirm that the aerosol plume passed over a polarization lidar (0.694 mm wavelength) site at the Arctic Facility for Atmospheric Remote Sensing at the University of Alaska Fairbanks. For the first time, lidar linear depolarization ratios of 0.10 – 0.15 were measured in a fresh tropospheric volcanic plume, demonstrating that the nonspherical glass and mineral particles typical of volcanic eruptions generate strong laser depolarization. Thus, polarization lidars can identify the volcanic ash plumes that pose a threat to jet air traffic from the ground, aircraft, or potentially from Earth orbit.

  20. A Systematic Review Regarding Tonometry and the Transmission of Infectious Diseases.

    PubMed

    Atkins, Nicole; Hodge, William; Li, Bruce

    2018-03-01

    Tonometry has been identified as a common method for measuring the intraocular pressure in patients. The direct contact between the tonometer and the eye may contribute to the risk of cross infection, especially of viral particles, from one patient to another. A systematic review was undertaken to address the likelihood of human immunodeficiency virus (HIV), hepatitis B virus, hepatitis C virus, and prion diseases transmission through the use of tonometers. Additionally, a comparison of the current tonometer disinfection methods is provided to assist with identifying which technique effectively reduces the risk of disease transmission. An electronic literature search was conducted using the following databases: Web of Science, EMBASE, CINAHL, SCOPUS, Biosis Previews, Cochrane Library, PubMed, and Google Scholar. Dissertation indexes were also searched, and these included: Dissertations and Abstracts, and Dissertations and Abstracts - UK/Ireland. Additionally, the Clinicaltrials.gov trial registry was searched to identify any other relevant literature. Two independent reviewers critically appraised the articles retrieved through the literature search. In total, 11 unique studies were deemed relevant for this systematic review. The available evidence demonstrated that the use of tonometers contributes to the transmission of these infectious diseases in vitro . The results also demonstrated variability in determining the most effective tonometer sterilization technique against these infectious diseases in vitro . There was limited evidence available regarding the transmission of HIV, hepatitis B, hepatitis C, and prion diseases through the use of tonometers. Additionally, due to the variability regarding the most effective sterilization techniques, it is difficult to identify which sterilization technique is most effective or adequately effective against these infectious diseases. Future research studies regarding infectious disease transmission through tonometry and sterilization techniques should be completed to more adequately inform infectious disease control guidelines.

  1. Myocardial Ischemia During Mental Stress: Role of Coronary Artery Disease Burden and Vasomotion

    PubMed Central

    Ramadan, Ronnie; Sheps, David; Esteves, Fabio; Maziar Zafari, A.; Douglas Bremner, J.; Vaccarino, Viola; Quyyumi, Arshed A.

    2013-01-01

    Background Mental stress–induced myocardial ischemia (MSIMI) is associated with adverse prognosis in patients with coronary artery disease (CAD), yet the mechanisms underlying this phenomenon remain unclear. We hypothesized that compared with exercise/pharmacological stress–induced myocardial ischemia (PSIMI) that is secondary to the atherosclerotic burden of CAD, MSIMI is primarily due to vasomotor changes. Methods and Results Patients with angiographically documented CAD underwent 99mTc‐sestamibi myocardial perfusion imaging at rest and following both mental and physical stress testing, performed on separate days. The severity and extent of CAD were quantified using the Gensini and Sullivan scores. Peripheral arterial tonometry (Itamar Inc) was used to assess the digital microvascular tone during mental stress as a ratio of pulse wave amplitude during speech compared with baseline. Measurements were made in a discovery sample (n=225) and verified in a replication sample (n=159). In the pooled (n=384) sample, CAD severity and extent scores were not significantly different between those with and without MSIMI, whereas they were greater in those with compared with those without PSIMI (P<0.04 for all). The peripheral arterial tonometry ratio was lower in those with compared with those without MSIMI (0.55±0.36 versus 0.76±0.52, P=0.009). In a multivariable analysis, the peripheral arterial tonometry ratio was the only independent predictor of MSIMI (P=0.009), whereas angiographic severity and extent of CAD independently predicted PSIMI. Conclusions The degree of digital microvascular constriction, and not the angiographic burden of CAD, is associated with MSIMI. Varying causes of MSIMI compared with PSIMI may require different therapeutic interventions that require further study. PMID:24145741

  2. Effects of topical anaesthetics and repeated tonometry on intraocular pressure.

    PubMed

    Jóhannesson, Gauti; Hallberg, Per; Eklund, Anders; Behndig, Anders; Lindén, Christina

    2014-03-01

    To investigate the effects of repeated measurements of intraocular pressure (IOP) using Goldmann applanation tonometry (GAT) and applanation resonance tonometry (ART) to identify mechanisms contributing to the expected IOP reduction. A prospective, single-centre study with six healthy volunteers. Consecutive repeated series (six measurements/serie/method) were made alternately on both eyes for 1 hr with oxybuprocaine/fluorescein in the right eye and tetracaine in the left. The left eye was Pentacam(®) photographed before and repeatedly for 20 min after the IOP measurements. On a separate occasion, the same volunteers received the same amount of anaesthetic drops for 1 hr but without repeated IOP measurements. A significant IOP reduction occurred with both ART and GAT in the oxybuprocaine-treated eye, -4.4 mmHg and -3.8 mmHg, respectively and with ART in the tetracaine eye, -2.1 mmHg. There was a significant difference in IOP reduction between the oxybuprocaine and tetracaine eyes with ART. There was a significant drop in anterior chamber volume (ACV) immediately after the IOP measurements, -12.6 μl that returned to pretrial level after 2 min. After 1 hr of receiving anaesthetic eye drops (without IOP measurements), the IOP decreased significantly in the oxybuprocaine eye for both ART and GAT, -3.1 and -1.7 mmHg, respectively, but not in the tetracaine eye (p = 0.72). The IOP reduction cannot be explained solely by aqueous humor being pressed out of the anterior chamber. While significant IOP reduction occurred with both tetracaine and oxybuprocaine after repeated mechanical applanation, the IOP reduction was significantly greater with oxybuprocaine. © 2013 The Authors. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.

  3. Effects of sapropterin on endothelium-dependent vasodilation in patients with CADASIL: a randomized controlled trial.

    PubMed

    De Maria, Renata; Campolo, Jonica; Frontali, Marina; Taroni, Franco; Federico, Antonio; Inzitari, Domenico; Tavani, Alessandra; Romano, Silvia; Puca, Emanuele; Orzi, Francesco; Francia, Ada; Mariotti, Caterina; Tomasello, Chiara; Dotti, Maria Teresa; Stromillo, Maria Laura; Pantoni, Leonardo; Pescini, Francesca; Valenti, Raffaella; Pelucchi, Claudio; Parolini, Marina; Parodi, Oberdan

    2014-10-01

    Cerebral autosomal-dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL), a rare autosomal dominant disorder caused by NOTCH3 mutations, is characterized by vascular smooth muscle and endothelial cells abnormalities, altered vasoreactivity, and recurrent lacunar infarcts. Vasomotor function may represent a key factor for disease progression. Tetrahydrobiopterin, essential cofactor for nitric oxide synthesis in endothelial cells, ameliorates endothelial function. We assessed whether supplementation with sapropterin, a synthetic tetrahydrobiopterin analog, improves endothelium-dependent vasodilation in CADASIL patients. In a 24-month, multicenter randomized, double-blind, placebo-controlled trial, CADASIL patients aged 30 to 65 years were randomly assigned to receive placebo or sapropterin 200 to 400 mg BID. The primary end point was change in the reactive hyperemia index by peripheral arterial tonometry at 24 months. We also assessed the safety and tolerability of sapropterin. Analysis was done by intention-to-treat. The intention-to-treat population included 61 patients. We found no significant difference between sapropterin (n=32) and placebo (n=29) in the primary end point (mean difference in reactive hyperemia index by peripheral arterial tonometry changes 0.19 [95% confidence interval, -0.18, 0.56]). Reactive hyperemia index by peripheral arterial tonometry increased after 24 months in 37% of patients on sapropterin and in 28% on placebo; however, after adjustment for age, sex, and clinical characteristics, improvement was not associated with treatment arm. The proportion of patients with adverse events was similar on sapropterin and on placebo (50% versus 48.3%); serious adverse events occurred in 6.3% versus 13.8%, respectively. Sapropterin was safe and well-tolerated at the average dose of 5 mg/kg/day, but did not affect endothelium-dependent vasodilation in CADASIL patients. https://www.clinicaltrialsregister.eu. Unique identifier: 2007-004370-55. © 2014 American Heart Association, Inc.

  4. The relation of digital vascular function to cardiovascular risk factors in African-Americans using digital tonometry: the Jackson Heart Study.

    PubMed

    McClendon, Eric E; Musani, Solomon K; Samdarshi, Tandaw E; Khaire, Sushant; Stokes, Donny; Hamburg, Naomi M; Sheffy, Koby; Mitchell, Gary F; Taylor, Herman R; Benjamin, Emelia J; Fox, Ervin R

    2017-06-01

    Digital vascular tone and function, as measured by peripheral arterial tonometry (PAT), are associated with cardiovascular risk and events in non-Hispanic whites. There are limited data on relations between PAT and cardiovascular risk in African-Americans. PAT was performed on a subset of Jackson Heart Study participants using a fingertip tonometry device. Resting digital vascular tone was assessed as baseline pulse amplitude. Hyperemic vascular response to 5 minutes of ischemia was expressed as the PAT ratio (hyperemic/baseline amplitude ratio). Peripheral augmentation index (AI), a measure of relative wave reflection, also was estimated. The association of baseline pulse amplitude (PA), PAT ratio, and AI to risk factors was assessed using stepwise multivariable models. The study sample consisted of 837 participants from the Jackson Heart Study (mean age, 54 ± 11 years; 61% women). In stepwise multivariable regression models, baseline pulse amplitude was related to male sex, body mass index, and diastolic blood pressure (BP), accounting for 16% of the total variability of the baseline pulse amplitude. Age, male sex, systolic BP, diastolic BP, antihypertensive medication, and prevalent cardiovascular disease contributed to 11% of the total variability of the PAT ratio. Risk factors (primarily age, sex, and heart rate) explained 47% of the total variability of the AI. We confirmed in our cohort of African-Americans, a significant relation between digital vascular tone and function measured by PAT and multiple traditional cardiovascular risk factors. Further studies are warranted to investigate the utility of these measurements in predicting clinical outcomes in African-Americans. Copyright © 2017 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  5. Transfer function-derived central pressure and cardiovascular disease events: the Framingham Heart Study.

    PubMed

    Mitchell, Gary F; Hwang, Shih-Jen; Larson, Martin G; Hamburg, Naomi M; Benjamin, Emelia J; Vasan, Ramachandran S; Levy, Daniel; Vita, Joseph A

    2016-08-01

    Relations between central pulse pressure (PP) or pressure amplification and major cardiovascular disease (CVD) events are controversial. Estimates of central aortic pressure derived using radial artery tonometry and a generalized transfer function may better predict CVD risk beyond the predictive value of brachial SBP. Augmentation index, central SBP, central PP, and central-to-peripheral PP amplification were evaluated using radial artery tonometry and a generalized transfer function as implemented in the SphygmoCor device (AtCor Medical, Itasca, Illinois, USA). We used proportional hazards models to examine relations between central hemodynamics and first-onset major CVD events in 2183 participants (mean age 62 years, 58% women) in the Framingham Heart Study. During median follow-up of 7.8 (limits 0.2-8.9) years, 149 participants (6.8%) had an incident event. Augmentation index (P = 0.6), central aortic systolic pressure (P = 0.20), central aortic PP (P = 0.24), and PP amplification (P = 0.15) were not related to CVD events in multivariable models that adjusted for age, sex, brachial cuff systolic pressure, use of antihypertensive therapy, total and high-density lipoprotein cholesterol concentrations, smoking, and presence of diabetes. In a model that included standard risk factors, model fit was improved (P = 0.03) when brachial systolic pressure was added after central, whereas model fit was not improved (P = 0.30) when central systolic pressure was added after brachial. After considering standard risk factors, including brachial cuff SBP, augmentation index, central PP and PP amplification derived using radial artery tonometry, and a generalized transfer function were not predictive of CVD risk.

  6. Incorporation of air into a snack food reduces energy intake

    PubMed Central

    Osterholt, Kathrin M.; Roe, Liane S.

    2007-01-01

    This study investigated how the air content of a familiar snack food affected energy intake and whether varying the method of serving the snack modified intake. We tested two versions of an extruded snack (cheese puffs) that were equal in energy density (5.7 kcal/g), but differed in energy per volume (less-aerated snack: 1.00 kcal/ml; more- aerated snack: 0.45 kcal/ml). In a within-subjects design, 16 women and 12 men consumed the snacks ad libitum in the laboratory during four afternoon sessions. A standard volume (1250 ml) of each snack was served once in a bowl and once in an opaque bag. Results showed that intake of the two snacks differed significantly by energy (p=0.0003) and volume (p<0.0001); subjects consumed 21% less weight and energy (70±17 kcal) of the more-aerated snack than the less-aerated snack, although they consumed a 73% greater volume of the more-aerated snack (239±24 ml). These findings suggest that subjects responded to both the weight and volume of the snack. Despite differences in intake, hunger and fullness ratings did not differ across conditions. The serving method did not significantly affect intake. Results from this study indicate that incorporating air into food provides a strategy to reduce energy intake from energy-dense snacks. PMID:17188782

  7. Test-retest reliability of pulse amplitude tonometry measures of vascular endothelial function: implications for clinical trial design.

    PubMed

    McCrea, Cindy E; Skulas-Ray, Ann C; Chow, Mosuk; West, Sheila G

    2012-02-01

    Endothelial dysfunction is an important outcome for assessing vascular health in intervention studies. However, reliability of the standard non-invasive method (flow-mediated dilation) is a significant challenge for clinical applications and multicenter trials. We evaluated the repeatability of pulse amplitude tonometry (PAT) to measure change in pulse wave amplitude during reactive hyperemia (Itamar Medical Ltd, Caesarea, Israel). Twenty healthy adults completed two PAT tests (mean interval = 19.5 days) under standardized conditions. PAT-derived measures of endothelial function (reactive hyperemia index, RHI) and arterial stiffness (augmentation index, AI) showed strong repeatability (intra-class correlations = 0.74 and 0.83, respectively). To guide future research, we also analyzed sample size requirements for a range of effect sizes. A crossover design powered at 0.90 requires 28 participants to detect a 15% change in RHI. Our study is the first to show that PAT measurements are repeatable in adults over an interval greater than 1 week.

  8. Endothelial health in childhood acute lymphoid leukemia survivors: pilot evaluation with peripheral artery tonometry.

    PubMed

    Ruble, Kathy; Davis, Catherine L; Han, Hae-Ra

    2015-03-01

    Childhood cancer survivors are a growing population at risk for poor cardiac outcomes. Acute lymphoid leukemia (ALL) survivors are among those at increased risk of cardiovascular complications. Early identification of impaired vascular health may allow for interventions to improve these outcomes. The purpose of this study was to evaluate vascular health using peripheral artery tonometry in ALL survivors and compare results with healthy siblings. Sixteen ALL survivor, healthy sibling pairs, aged 8 to 20 years, were evaluated for vascular health and cardiovascular risk factors (body mass index, central adiposity, blood pressure, and fitness). One-tailed paired t test was used to compare the groups. Survivors were similar to siblings in cardiovascular risk measures but had poorer vascular health as measured by reactive hyperemia index (survivor RHI 1.54 vs. sibling 1.77; P=0.0474). This study reveals that even among survivors who are comparable to their healthy siblings in other traditional cardiovascular risks, there is evidence of poorer vascular health.

  9. [What should we think? Is pneumotonometry still reliable?].

    PubMed

    Bresson-Dumont, H; Lehoux, A; Kponoume, C; Santiago, P-Y

    2007-05-01

    Noncontact tonometer (NCT) is an applanation tonometry, as is Goldmann tonometry. Numerous studies have shown the reliability of this technique but problems still exist. We measured intraocular pressure (IOP) in 340 patients (668 eyes) with NCT and Goldmann tonometer (GAT). To evaluate the influence of central corneal thickness (CCT), we classified the patients according to their CCT (<500 microm; between 520 and 580 microm, and>600 microm). The mean difference between the two IOP measurements was -1.4 mmHg +/- 2.67 (-12 to +7), p<0,0001 for the thinner corneas, +0.13 mmHg +/- 2.67 (-8 to +8), p=0.445 for the regular corneas, and + 3.04 mmHg +/- 3.2 (-7 to +13) p<0.0001 for the thicker corneas. CCT influences NCT and GAT, but the difference between the two techniques is higher for thicker CCTs, higher IOPs, and in younger patients. NCT is good for glaucoma screening but is less reliable than GAT for glaucoma follow-up if CCT and IOP are far from regular values.

  10. Blood-gas analyzer calibration and quality control using a precision gas-mixing instrument.

    PubMed

    Wallace, W D; Clark, J S; Cutler, C A

    1981-08-01

    We describe a new instrument that performs on-site mixing of oxygen (O2), carbon dioxide (CO2), and nitrogen (N2) to create compositions that can replace gases from standard premixed cylinders. This instrument yields accurate and predictable gas mixtures that can be used for two-point gas calibration of blood gas/pH analyzers or for liquid tonometry of either an aqueous buffer or blood used as quality-control material on blood-gas electrodes. The desired mixture of O2, CO2, and N2 is produced by microprocessor control of the sequential open-times on three solenoid valves that meter these pure gases through a common small-bore orifice. Any combination of O2 and CO2 can be chosen by dialing the front panel thumbwheels and pressing a button. Gas chromatographic evaluation of this gas-mixing instrument demonstrates its accuracy and precision to be better than +/- 0.1% absolute full scale for O2, CO2, and N2, making this instrument calibration and tonometry.

  11. Temperature Dependence of IP3-Mediated Local and Global Ca2+ Signals

    PubMed Central

    Dickinson, George D.; Parker, Ian

    2013-01-01

    We examined the effect of temperature (12–40°C) on local and global Ca2+ signals mediated by inositol trisphosphate receptor/channels (IP3R) in human neuroblastoma (SH-SY5Y) cells. The amplitudes and spatial spread of local signals arising from single IP3R (blips) and clusters of IP3R (puffs) showed little temperature dependence, whereas their kinetics (durations and latencies) were markedly accelerated by increasing temperature. In contrast, the amplitude of global Ca2+ waves increased appreciably at lower temperatures, probably as a result of the longer duration of IP3R channel opening. Several parameters, including puff and blip durations, puff latency and frequency, and frequency of repetitive Ca2+ waves, showed a biphasic temperature dependence on Arrhenius plots. In all cases the transition temperature occurred at ∼25°C, possibly reflecting a phase transition in the lipids of the endoplasmic reticulum membrane. Although the IP3-evoked Ca2+ signals were qualitatively similar at 25°C and 36°C, one should consider the temperature sensitivity of IP3-mediated signal amplitudes when extrapolating from room temperature to physiological temperature. Conversely, further cooling may be advantageous to improve the optical resolution of channel gating kinetics. PMID:23442860

  12. What reaches the antenna? How to calibrate odor flux and ligand-receptor affinities.

    PubMed

    Andersson, Martin N; Schlyter, Fredrik; Hill, Sharon Rose; Dekker, Teun

    2012-06-01

    Physiological studies on olfaction frequently ignore the airborne quantities of stimuli reaching the sensory organ. We used a gas chromatography-calibrated photoionization detector to estimate quantities released from standard Pasteur pipette stimulus cartridges during repeated puffing of 27 compounds and verified how lack of quantification could obscure olfactory sensory neuron (OSN) affinities. Chemical structure of the stimulus, solvent, dose, storage condition, puff interval, and puff number all influenced airborne quantities. A model including boiling point and lipophilicity, but excluding vapor pressure, predicted airborne quantities from stimuli in paraffin oil on filter paper. We recorded OSN responses of Drosophila melanogaster, Ips typographus, and Culex quinquefasciatus, to known quantities of airborne stimuli. These demonstrate that inferred OSN tuning width, ligand affinity, and classification can be confounded and require stimulus quantification. Additionally, proper dose-response analysis shows that Drosophila AB3A OSNs are not promiscuous, but highly specific for ethyl hexanoate, with other earlier proposed ligands 10- to 10 000-fold less potent. Finally, we reanalyzed published Drosophila OSN data (DoOR) and demonstrate substantial shifts in affinities after compensation for quantity and puff number. We conclude that consistent experimental protocols are necessary for correct OSN classification and present some simple rules that make calibration, even retroactively, readily possible.

  13. Arterial Tonometry in the Classroom

    ERIC Educational Resources Information Center

    Werner, Timothy; Boutagy, Nabil

    2015-01-01

    The study of hemodynamic physiology utilizing traditional methods presents many challenges and limitations to educators. The goal of the educator is to provide the student with an adequate understanding of the basic hemodynamic anatomy and physiology governing blood flow, cardiac cycle and associated Korotkoff sounds, and the pathophysiology of…

  14. 21 CFR 524.1982 - Proparacaine ophthalmic solution.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... is used as an anesthetic in cauterization of corneal ulcers, removal of foreign bodies and sutures from the cornea, and measurement of intraocular pressure (tonometry) when glaucoma is suspected; as an... cauterization of corneal ulcers, removal of foreign bodies and sutures from the cornea, and measurement of...

  15. Recovery of gonadal development in tiger puffer Takifugu rubripes after exposure to 17β-estradiol during early life stages

    NASA Astrophysics Data System (ADS)

    Hu, Peng; Liu, Bin; Meng, Zhen; Liu, Xinfu; Jia, Yudong; Yang, Zhi; Lei, Jilin

    2017-05-01

    The aim of the present study was to investigate the long-term effects of 17β-estradiol (E2) exposure on gonadal development in the tiger puff er ( Takifugu rubripes), which has a genetic sex determination system of male homogametic XY-XX. Tiger puff er larvae were exposed to 1, 10 and 100 μg/L E2 from 15 to 100 days post-hatch (dph) and then maintained in clean seawater until 400 dph. Changes in sex ratio, gonadal structure and gonadosomatic index (GSI) were monitored at 100, 160, 270 and 400 dph. Sex-associated single nucleotide polymorphism (SNP) markers were used to analyze the genetic sex of samples, except those at 100 dph. Exposure had a positive effect on the conversion of genetically male gonads into phenotypically female gonads at 100 dph. However, gonads from 60% of genetic XY males in the 1-μg/L E2 group and 100% in the 10-μg/L E2 group developed intersexual gonads at 160 dph; gonads of all genetic XY males in the two treatment groups reverted to testis by 270 dph. While 38%, 57% and 44% of gonads of XY fish in the 100-μg/L E2 group reverted to intersexual gonads at 160, 270 and 400 dph, respectively, none reverted to testis after E2 treatment. In addition, E2 exposure inhibited gonadal growth of both genetic sexes, as indicated by the clear dose-dependent decrease in GSI at 270 and 400 dph. The results showed that exposure to E2 during the early life stages of tiger puff er disrupted gonadal development, but that fish recovered after migration to clean seawater. The study suggests the potential use of tiger puff er as a valuable indicator species to evaluate the effects of environmental estrogens on marine fish, thereby protecting valuable fishery resources.

  16. First Argon Gas Puff Experiments With 500 ns Implosion Time On Sphinx Driver

    NASA Astrophysics Data System (ADS)

    Zucchini, F.; Calamy, H.; Lassalle, F.; Loyen, A.; Maury, P.; Grunenwald, J.; Georges, A.; Morell, A.; Bedoch, J.-P.; Ritter, S.; Combes, P.; Smaniotto, O.; Lample, R.; Coleman, P. L.; Krishnan, M.

    2009-01-01

    Experiments have been performed at the SPHINX driver to study potential of an Argon Gas Puff load designed by AASC. We present here the gas Puff hardware and results of the last shot series. The Argon Gas Puff load used is injected thanks to a 20 cm diameter nozzle. The nozzle has two annuli and a central jet. The pressure and gas type in each of the nozzle plena can be independently adjusted to tailor the initial gaz density distribution. This latter is selected as to obtain an increasing radial density from outer shell towards the pinch axis in order to mitigate the RT instabilities and to increase radiating mass on axis. A flashboard unit produces a high intensity UV source to pre-ionize the Argon gas. Typical dimensions of the load are 200 mm in diameter and 40 mm height. Pressures are adjusted to obtain an implosion time around 550 ns with a peak current of 3.5 MA. With the goal of improving k-shell yield a mass scan of the central jet was performed and implosion time, mainly given by outer and middle plena settings, was kept constant. Tests were also done to reduce the implosion time for two configurations of the central jet. Strong zippering of the radiation production was observed mainly due to the divergence of the central jet over the 40 mm of the load height. Due to that feature k-shell radiation is mainly obtained near cathode. Therefore tests were done to mitigate this effect first by adjusting local pressure of middle and central jet and second by shortening the pinch length. At the end of this series, best shot gave 5 kJ of Ar k-shell yield. PCD detectors showed that k-shell x-ray power was 670 GW with a FWHM of less than 10 ns.

  17. Breeding Super-Earths and Birthing Super-puffs in Transitional Disks

    NASA Astrophysics Data System (ADS)

    Lee, Eve J.; Chiang, Eugene

    2016-02-01

    The riddle posed by super-Earths (1-4R⊕, 2-20M⊕) is that they are not Jupiters: their core masses are large enough to trigger runaway gas accretion, yet somehow super-Earths accreted atmospheres that weigh only a few percent of their total mass. We show that this puzzle is solved if super-Earths formed late, as the last vestiges of their parent gas disks were about to clear. This scenario would seem to present fine-tuning problems, but we show that there are none. Ambient gas densities can span many (in one case up to 9) orders of magnitude, and super-Earths can still robustly emerge after ˜0.1-1 Myr with percent-by-weight atmospheres. Super-Earth cores are naturally bred in gas-poor environments where gas dynamical friction has weakened sufficiently to allow constituent protocores to gravitationally stir one another and merge. So little gas is present at the time of core assembly that cores hardly migrate by disk torques: formation of super-Earths can be in situ. The basic picture—that close-in super-Earths form in a gas-poor (but not gas-empty) inner disk, fed continuously by gas that bleeds inward from a more massive outer disk—recalls the largely evacuated but still accreting inner cavities of transitional protoplanetary disks. We also address the inverse problem presented by super-puffs: an uncommon class of short-period planets seemingly too voluminous for their small masses (4-10R⊕, 2-6M⊕). Super-puffs most easily acquire their thick atmospheres as dust-free, rapidly cooling worlds outside ˜1 AU where nebular gas is colder, less dense, and therefore less opaque. Unlike super-Earths, which can form in situ, super-puffs probably migrated in to their current orbits; they are expected to form the outer links of mean-motion resonant chains, and to exhibit greater water content. We close by confronting observations and itemizing remaining questions.

  18. Determination of Chemical Compounds Generated from Second-generation E-cigarettes Using a Sorbent Cartridge Followed by a Two-step Elution Method.

    PubMed

    Uchiyama, Shigehisa; Senoo, Yui; Hayashida, Hideki; Inaba, Yohei; Nakagome, Hideki; Kunugita, Naoki

    2016-01-01

    We developed an analytical method for analyzing electronic cigarette (E-cigarette) smoke, and measured the carbonyl compounds and volatile organic compounds generated by 10 brands of second-generation E-cigarettes. A glass filter (Cambridge filter pad) for particulate matter and a solid sorbent tube packed with Carboxen-572 for gaseous compounds were used to collect E-cigarette smoke. These were then analyzed using a two-step elution method with carbon disulfide and methanol, followed by high-performance liquid chromatography (HPLC) and gas chromatography mass spectrometry (GC/MS). Formaldehyde (FA), acetaldehyde (AA), acetone (AC), acrolein (ACR), propanal (PA), acetol (AT), glyoxal (GO), and methyl glyoxal (MGO) were detected by HPLC in some E-cigarettes. Propylene glycol (PG), glycerol (GLY), and some esters were detected by GC/MS. GO and MGO exist mainly as particulate matter. AA, AC, ACR, PA, and AT exist mainly as gaseous compounds. FA exists as both particulate matter and gaseous compounds. These carbonyl compounds have carbon numbers C1 - C3. The main components of E-liquid are PG (C3) and GLY (C3). Therefore, the oxidation of liquids, such as PG and GLY in E-cigarettes upon incidental contact with the heating element in E-cigarette, is suggested as being a possible cause for carbonyl generation. When the puff number exceeds a critical point, carbonyl generation rapidly increases and then remains constant. The results of this study are now being used to determine the following E-cigarette smoking protocol: puff volume, 55 mL; puff duration, 2 s; and puff number, 30. E-cigarette analysis revealed very large variation in carbonyl concentration among not only different brands, but also different samples of the same product. Typical distributions of carbonyl concentration were not observed in any of the E-cigarettes tested, and the mean values greatly differed from median values.

  19. 2D.02: ACCURACY OF ISOVOLUMETRIC CONTRACTION TIME OBTAINED BY CAROTID ARTERIAL TONOMETRY IN PATIENTS WITH CHRONIC LEFT VENTRICULAR FAILURE.

    PubMed

    Salvi, L; Grillo, A; Marelli, S; Gao, L; Giuliano, A; Trifirò, G; Santini, F; Pini, A; Salvi, P; Viecca, F; Carretta, R; Parati, G

    2015-06-01

    The Buckberg index (SEVR: subendocardial viability ratio) is considered a useful parameter for a non-invasive assessment of the relationship between subendocardial oxygen supply and demand. However, his classic calculation does not include the pre-ejection isovolumic contraction time in stroke work evaluation. The aim of our study was to evaluate the accuracy of the isovolumic contraction time obtained through the carotid pulse wave analysis, to be included in SEVR assessment. In 35 patients (mean age ± SD = 66 ± 13 yrs) followed-up for chronic left ventricular systolic failure (EF = 32 ± 8%) with no significant valvular disease, the pressure curve in the common carotid artery by tonometer (PulsePen) and the aortic transvalvular flow by EchocardioDoppler (Philips-EnVisor C-HD) were acquired simultaneously. The synchronization of data acquisition was verified by comparison of the RR intervals in the ECG signals recorded simultaneously to the two methods. The isovolumic contraction time was separately calculated by considering both the delay between the beginning of the aortic flow wave obtained by EchocardioDoppler and the R wave of the corresponding ECG, and the delay between the foot of the pressure wave recorded in the carotid artery by tonometry compared with the R wave of the corresponding ECG. The latter was corrected by considering the delay between ascending aorta and carotid pulses, computed as a function of the carotid-femoral pulse wave speed and of the distance between the point of carotid pulse acquisition and the sternal notch. The isovolumic contraction time computed by tonometry (68.8 ± 20.2 ms) was closely related to that measured with the EchocardioDoppler approach (68.8 ± 20.5 ms): y = 0.93x + 4.94; r = 0.93; p < 0.0001, with homogeneous distribution in Bland-Altman analysis (mean difference -0.1 ± 7.57 ms). The ratios between isovolumic contraction time and systolic ejection time separately obtained with the two methods (24.8 ± 8.3% and 22.2 ± 8.5%, respectively) were closely related: y = 0.93x + 1.67; r = 0.90 (mean difference -0.1 ± 2.7%). Thus, carotid arterial tonometry allows an accurate and simple assessment of the isovolumic contraction time, which can be employed to improve the assessment of SEVR by also considering the isovolumic contraction time in the stroke work evaluation.

  20. Impact analysis of traffic-related air pollution based on real-time traffic and basic meteorological information.

    PubMed

    Pan, Long; Yao, Enjian; Yang, Yang

    2016-12-01

    With the rapid development of urbanization and motorization in China, traffic-related air pollution has become a major component of air pollution which constantly jeopardizes public health. This study proposes an integrated framework for estimating the concentration of traffic-related air pollution with real-time traffic and basic meteorological information and also for further evaluating the impact of traffic-related air pollution. First, based on the vehicle emission factor models sensitive to traffic status, traffic emissions are calculated according to the real-time link-based average traffic speed, traffic volume, and vehicular fleet composition. Then, based on differences in meteorological conditions, traffic pollution sources are divided into line sources and point sources, and the corresponding methods to determine the dynamic affecting areas are also proposed. Subsequently, with basic meteorological data, Gaussian dispersion model and puff integration model are applied respectively to estimate the concentration of traffic-related air pollution. Finally, the proposed estimating framework is applied to calculate the distribution of CO concentration in the main area of Beijing, and the population exposure is also calculated to evaluate the impact of traffic-related air pollution on public health. Results show that there is a certain correlation between traffic indicators (i.e., traffic speed and traffic intensity) of the affecting area and traffic-related CO concentration of the target grid, which indicates the methods to determine the affecting areas are reliable. Furthermore, the reliability of the proposed estimating framework is verified by comparing the predicted and the observed ambient CO concentration. In addition, results also show that the traffic-related CO concentration is higher in morning and evening peak hours, and has a heavier impact on public health within the Fourth Ring Road of Beijing due to higher population density and higher CO concentration under calm wind condition in this area. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Progressive Reduction in Central Blood Volume is not Detected by Sublingual Capnography

    DTIC Science & Technology

    2012-01-01

    Sam Houston; †Department of Health and Kinesiology , University of Texas at San Antonio, San Antonio, and ‡San Antonio Military Medical Center, Fort...of hypovolaemia with gastrointestinal tonometry. Intensive Care Med 23(3):276 281, 1997. 13. Santoso JT, Wisner DH, Battistella FD, Owings JT

  2. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode.

    PubMed

    Poehlmann, Flavio R; Cappelli, Mark A; Rieker, Gregory B

    2010-12-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma deflagration. The effects of varying the bank capacitance, transmission line inductance, and applied electrode voltage were studied over the range from 14 to 112 μF, 50 to 200 nH, and 1 to 3 kV, respectively.

  3. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode

    PubMed Central

    Poehlmann, Flavio R.; Cappelli, Mark A.; Rieker, Gregory B.

    2010-01-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma deflagration. The effects of varying the bank capacitance, transmission line inductance, and applied electrode voltage were studied over the range from 14 to 112 μF, 50 to 200 nH, and 1 to 3 kV, respectively. PMID:21267082

  4. Comparison of simulation and experimental results for a gas puff nozzle on Ambiorix

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnier, J-N.; Chevalier, J-M.; Dubroca, B.

    One of source term of Z-Pinch experiments is the gas puff density profile. In order to characterize the gas jet, an experiment based on interferometry has been performed. The first study was a point measurement (a section density profile) which led us to develop a global and instantaneous interferometry imaging method. In order to optimise the nozzle, we simulated the experiment with a flow calculation code (ARES). In this paper, the experimental results are compared with simulations. The different gas properties (He, Ne, Ar) and the flow duration lead us to take care, on the one hand, of the gasmore » viscosity, and on the other, of modifying the code for an instationary flow.« less

  5. The structural genes for three Drosophila glue proteins reside at a single polytene chromosome puff locus.

    PubMed Central

    Crowley, T E; Bond, M W; Meyerowitz, E M

    1983-01-01

    The polytene chromosome puff at 68C on the Drosophila melanogaster third chromosome is thought from genetic experiments to contain the structural gene for one of the secreted salivary gland glue polypeptides, sgs-3. Previous work has demonstrated that the DNA included in this puff contains sequences that are transcribed to give three different polyadenylated RNAs that are abundant in third-larval-instar salivary glands. These have been called the group II, group III, and group IV RNAs. In the experiments reported here, we used the nucleotide sequence of the DNA coding for these RNAs to predict some of the physical and chemical properties expected of their protein products, including molecular weight, amino acid composition, and amino acid sequence. Salivary gland polypeptides with molecular weights similar to those expected for the 68C RNA translation products, and with the expected degree of incorporation of different radioactive amino acids, were purified. These proteins were shown by amino acid sequencing to correspond to the protein products of the 68C RNAs. It was further shown that each of these proteins is a part of the secreted salivary gland glue: the group IV RNA codes for the previously described sgs-3, whereas the group II and III RNAs code for the newly identified glue polypeptides sgs-8 and sgs-7. Images PMID:6406838

  6. Transport phenomena governing nicotine emissions from electronic cigarettes: model formulation and experimental investigation

    PubMed Central

    Talih, Soha; Balhas, Zainab; Salman, Rola; El-Hage, Rachel; Karaoghlanian, Nareg; El-Hellani, Ahmad; Baassiri, Mohamad; Jaroudi, Ezzat; Eissenberg, Thomas; Saliba, Najat; Shihadeh, Alan

    2017-01-01

    Electronic cigarettes (ECIGs) electrically heat and aerosolize a liquid containing propylene glycol (PG), vegetable glycerin (VG), flavorants, water, and nicotine. ECIG effects and proposed methods to regulate them are controversial. One regulatory focal point involves nicotine emissions. We describe a mathematical model that predicts ECIG nicotine emissions. The model computes the vaporization rate of individual species by numerically solving the unsteady species and energy conservation equations. To validate model predictions, yields of nicotine, total particulate matter, PG, and VG were measured while manipulating puff topography, electrical power, and liquid composition across 100 conditions. Nicotine flux, the rate at which nicotine is emitted per unit time, was the primary outcome. Across conditions, the measured and computed nicotine flux were highly correlated (r = 0.85, p<.0001). As predicted, device power, nicotine concentration, PG/VG ratio, and puff duration influenced nicotine flux (p<.05), while water content and puff velocity did not. Additional empirical investigation revealed that PG/VG liquids act as ideal solutions, that liquid vaporization accounts for more than 95% of ECIG aerosol mass emissions, and that as device power increases the aerosol composition shifts towards the less volatile components of the parent liquid. To the extent that ECIG regulations focus on nicotine emissions, mathematical models like this one can be used to predict ECIG nicotine emissions and to test the effects of proposed regulation of factors that influence nicotine flux. PMID:28706340

  7. Time-resolved analysis of the emission of sidestream smoke (SSS) from cigarettes during smoking by photo ionisation/time-of-flight mass spectrometry (PI-TOFMS): towards a better description of environmental tobacco smoke.

    PubMed

    Streibel, T; Mitschke, S; Adam, T; Zimmermann, R

    2013-09-01

    In this study, the chemical composition of sidestream smoke (SSS) emissions of cigarettes are characterised using a laser-based single-photon ionisation time-of-flight mass spectrometer. SSS is generated from various cigarette types (2R4F research cigarette; Burley, Oriental and Virginia single-tobacco-type cigarettes) smoked on a single-port smoking machine and collected using a so-called fishtail chimney device. Using this setup, a puff-resolved quantification of several SSS components was performed. Investigations of the dynamics of SSS emissions show that concentration profiles of various substances can be categorised into several groups, either depending on the occurrence of a puff or uninfluenced by the changes in the burning zone during puffing. The SSS emissions occurring directly after a puff strongly resemble the composition of mainstream smoke (MSS). In the smouldering phase, clear differences between MSS and SSS are observed. The changed chemical profiles of SSS and MSS might be also of importance on environmental tobacco smoke which is largely determined by SSS. Additionally, the chemical composition of the SSS is strongly affected by the tobacco type. Hence, the higher nitrogen content of Burley tobacco leads to the detection of increased amounts of nitrogen-containing substances in SSS.

  8. Can one puff really make an adolescent addicted to nicotine? A critical review of the literature

    PubMed Central

    2010-01-01

    Rationale In the past decade, there have been various attempts to understand the initiation and progression of tobacco smoking among adolescents. One line of research on these issues has made strong claims regarding the speed in which adolescents can become physically and mentally addicted to smoking. According to these claims, and in contrast to other models of smoking progression, adolescents can lose autonomy over their smoking behavior after having smoked one puff in their lifetime and never having smoked again, and can become mentally and physically "hooked on nicotine" even if they have never smoked a puff. Objectives To critically examine the conceptual and empirical basis for the claims made by the "hooked on nicotine" thesis. Method We reviewed the major studies on which the claims of the "hooked on nicotine" research program are based. Results The studies we reviewed contained substantive conceptual and methodological flaws. These include an untenable and idiosyncratic definition of addiction, use of single items or of very lenient criteria for diagnosing nicotine dependence, reliance on responders' causal attributions in determining physical and mental addiction to nicotine and biased coding and interpretation of the data. Discussion The conceptual and methodological problems detailed in this review invalidate many of the claims made by the "hooked on nicotine" research program and undermine its contribution to the understanding of the nature and development of tobacco smoking in adolescents. PMID:21067587

  9. Acceleration of Hydrogen Ions up to 30 MeV and Generation of 3 × 1012 Neutrons in Megaampere Deuterium Gas-Puff Z-Pinch

    NASA Astrophysics Data System (ADS)

    Klir, D.; Cikhardt, J.; Kravarik, J.; Kubes, P.; Rezac, K.; Sila, O.; Shishlov, A.; Cherdizov, R.; Fursov, F.; Kokshenev, V.; Kovalchuk, B.; Kurmaev, N.; Labetsky, A.; Ratakhin, N.; Orcikova, H.; Turek, K.

    2013-10-01

    Fusion neutrons were produced with a deuterium gas-puff z-pinch on the GIT-12 generator at the Institute of High Current Electronics in Tomsk. The peak neutron yield from DD reactions reached Yn = (2 . 9 +/- 0 . 3) ×1012 at 100 μg/cm linear mass density of deuterium, 700 ns implosion time and 2.7 MA current. Such a neutron yield means that the scaling law of deuterium z-pinches Yn ~I4 was extended to 3 MA currents. The further increase of neutron yields up to (3 . 7 +/- 0 . 4) ×1012 was achieved by placing a deuterated polyethylene catcher onto the axis. Maximum neutron energies of 15 and 22 MeV were observed by radial and axial nToF detectors, respectively. A stack of CR-39 track detectors showed up to 40 MeV deuterons (or 30 MeV protons) on the z-pinch axis. Since the energy input into plasmas was 70 kJ, the number of DD neutrons per one joule of stored plasma energy exceeded the value of 5 ×107 . This value implies that deuterium gas-puff z-pinches belong to the most efficient plasma-based sources of DD neutrons. This work was partially supported by the GACR grant No. P205/12/0454 and by the RFBR research project No. 13-08-00479-a.

  10. Interchange Reconnection Associated with a Confined Filament Eruption: Implications for the Source of Transient Cold-dense Plasma in Solar Winds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Ruisheng; Chen, Yao; Wang, Bing

    The cold-dense plasma is occasionally detected in the solar wind with in situ data, but the source of the cold-dense plasma remains illusive. Interchange reconnections (IRs) between closed fields and nearby open fields are known to contribute to the formation of solar winds. We present a confined filament eruption associated with a puff-like coronal mass ejection (CME) on 2014 December 24. The filament underwent successive activations and finally erupted, due to continuous magnetic flux cancelations and emergences. The confined erupting filament showed a clear untwist motion, and most of the filament material fell back. During the eruption, some tiny blobsmore » escaped from the confined filament body, along newly formed open field lines rooted around the south end of the filament, and some bright plasma flowed from the north end of the filament to remote sites at nearby open fields. The newly formed open field lines shifted southward with multiple branches. The puff-like CME also showed multiple bright fronts and a clear southward shift. All the results indicate an intermittent IR existed between closed fields of the confined erupting filament and nearby open fields, which released a portion of filament material (blobs) to form the puff-like CME. We suggest that the IR provides a possible source of cold-dense plasma in the solar wind.« less

  11. Multicolor, time-gated, soft x-ray pinhole imaging of wire array and gas puff Z pinches on the Z and Saturn pulsed power generators.

    PubMed

    Jones, B; Coverdale, C A; Nielsen, D S; Jones, M C; Deeney, C; Serrano, J D; Nielsen-Weber, L B; Meyer, C J; Apruzese, J P; Clark, R W; Coleman, P L

    2008-10-01

    A multicolor, time-gated, soft x-ray pinhole imaging instrument is fielded as part of the core diagnostic set on the 25 MA Z machine [M. E. Savage et al., in Proceedings of the Pulsed Power Plasma Sciences Conference (IEEE, New York, 2007), p. 979] for studying intense wire array and gas puff Z-pinch soft x-ray sources. Pinhole images are reflected from a planar multilayer mirror, passing 277 eV photons with <10 eV bandwidth. An adjacent pinhole camera uses filtration alone to view 1-10 keV photons simultaneously. Overlaying these data provides composite images that contain both spectral as well as spatial information, allowing for the study of radiation production in dense Z-pinch plasmas. Cu wire arrays at 20 MA on Z show the implosion of a colder cloud of material onto a hot dense core where K-shell photons are excited. A 528 eV imaging configuration has been developed on the 8 MA Saturn generator [R. B. Spielman et al., and A. I. P. Conf, Proc. 195, 3 (1989)] for imaging a bright Li-like Ar L-shell line. Ar gas puff Z pinches show an intense K-shell emission from a zippering stagnation front with L-shell emission dominating as the plasma cools.

  12. Olive Oil Based Emulsions in Frozen Puff Pastry Production

    NASA Astrophysics Data System (ADS)

    Gabriele, D.; Migliori, M.; Lupi, F. R.; de Cindio, B.

    2008-07-01

    Puff pastry is an interesting food product having different industrial applications. It is obtained by laminating layers of dough and fats, mainly shortenings or margarine, having specific properties which provides required spreading characteristic and able to retain moisture into dough. To obtain these characteristics, pastry shortenings are usually saturated fats, however the current trend in food industry is mainly oriented towards unsatured fats such as olive oil, which are thought to be safer for human health. In the present work, a new product, based on olive oil, was studied as shortening replacer in puff pastry production. To ensure the desired consistency, for the rheological matching between fat and dough, a water-in-oil emulsion was produced based on olive oil, emulsifier and a hydrophilic thickener agent able to increase material structure. Obtained materials were characterized by rheological dynamic tests in linear viscoelastic conditions, aiming to setup process and material consistency, and rheological data were analyzed by using the weak gel model. Results obtained for tested emulsions were compared to theological properties of a commercial margarine, adopted as reference value for texture and stability. Obtained emulsions are characterized by interesting rheological properties strongly dependent on emulsifier characteristics and water phase composition. However a change in process temperature during fat extrusion and dough lamination seems to be necessary to match properly typical dough rheological properties.

  13. Comparison between standard Goldmann applanation prism and disposable applanation prism in tonometry.

    PubMed

    Goel, S; Chua, C; Dong, B; Butcher, M; Ahfat, F; Hindi, S K; Kotta, S

    2004-02-01

    Disposable devices are increasingly becoming the preferred choice where possible in contact medical equipment. To evaluate the accuracy of the disposable applanation tonometer head as a potential substitute to the standard Goldmann applanation head. The study was prospective. The intraocular pressure recordings in 80 eyes of 42 patients were compared using the disposable and standard Goldmann applanator heads. The Bland and Altman method of assessing agreement between two methods of clinical measurement was used in the analysis. The difference in the readings between the two types of tonometer heads was highly variable (mean difference=0.78 mm Hg, range=-1 to 11 mm Hg). This was because of the distortions on the applanating surface of the disposable device. When the readings associated with the defective heads were excluded, very strong agreement was obtained (mean=0.07 mm Hg, range=-1 to 2 mm Hg). Good agreement with standard Goldmann applanation is achieved with the disposable heads except where surface distortions induce significant errors. Careful inspection to ensure well-structured disposable units is imperative in disposable applanation tonometry.

  14. Non-invasive method for the aortic blood pressure waveform estimation using the measured radial EBI

    NASA Astrophysics Data System (ADS)

    Krivoshei, Andrei; Lamp, Jürgen; Min, Mart; Uuetoa, Tiina; Uuetoa, Hasso; Annus, Paul

    2013-04-01

    The paper presents a method for the Central Aortic Pressure (CAP) waveform estimation from the measured radial Electrical Bio-Impedance (EBI). The method proposed here is a non-invasive and health-safe approach to estimate the cardiovascular system parameters, such as the Augmentation Index (AI). Reconstruction of the CAP curve from the EBI data is provided by spectral domain transfer functions (TF), found on the bases of data analysis. Clinical experiments were carried out on 30 patients in the Center of Cardiology of East-Tallinn Central Hospital during coronary angiography on patients in age of 43 to 80 years. The quality and reliability of the method was tested by comparing the evaluated augmentation indices obtained from the invasively measured CAP data and from the reconstructed curve. The correlation coefficient r = 0.89 was calculated in the range of AICAP values from 5 to 28. Comparing to the traditional tonometry based method, the developed one is more convenient to use and it allows long-term monitoring of the AI, what is not possible with tonometry probes.

  15. Twenty-four–Hour Measurement of Intraocular Pressure in Guinea Pigs (Cavia porcellus)

    PubMed Central

    Ansari-Mood, Maneli; Mehdi-Rajaei, Seyed; Sadjadi, Reza; Selk-Ghaffari, Masoud; Williams, David L

    2016-01-01

    The objective of this study was to measure intraocular pressure (IOP) in intact, healthy guinea pigs (15 male, 15 female) every 2 h for a 24-h period. First, IOP was measured by using rebound tonometry (RBT). After a 1-min rest period, 0.5% proparacaine ophthalmic solution, a topical anesthetic, was applied to both eyes; 4 min after anesthetic instillation, IOP was measured by using applanation tonometry (APT). The IOP was lower during the light period (0700 to 1900) than during the dark phase (2000 to 0600). The lowest IOP by both RBT and APT (3.68 and 13.37 mm Hg, respectively) occurred at 0700, whereas maximal IOP occurred at 2300 for RBT (8.12 mm Hg) but at 2100 for APT (20.62 mm Hg). No significant differences in IOP between the left and right eyes or between RBT and APT were noted. In addition, daily variations in the IOP of guinea pigs seem to be independent of sex and body weight. The results of this study may be beneficial in the diagnosis and observation of glaucoma in guinea pigs. PMID:26817986

  16. Application of bio-huff-`n`-puff technology at Jilin oil field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiu-Yuan Wang; Yan-Fed Xue; Gang Dai

    1995-12-31

    An enriched culture 48, capable of adapting to the reservoir conditions and fermenting molasses to produce gas and acid, was used as an inoculum for bio- huff-`n`-puff tests at Fuyu oil area of Jilin oil field. The production well was injected with water containing 4-6% (v/v) molasses and inoculum, and then shut in. After 15-21 days, the well was placed back in operation. A total of 44 wells were treated, of which only two wells showed no effects. The daily oil production of treated wells increased by 33.3-733.3%. Up to the end of 1994, the oil production was increased bymore » 204 tons per well on average. Results obtained from various types of production wells were discussed.« less

  17. Developing the Pulsed Fission-Fusion (PuFF) Engine

    NASA Technical Reports Server (NTRS)

    Adams, Robert B.; Cassibry, Jason; Bradley, David; Fabisinski, Leo; Statham, Geoffrey

    2014-01-01

    In September 2013 the NASA Innovative Advanced Concept (NIAC) organization awarded a phase I contract to the PuFF team. Our phase 1 proposal researched a pulsed fission-fusion propulsion system that compressed a target of deuterium (D) and tritium (T) as a mixture in a column, surrounded concentrically by Uranium. The target is surrounded by liquid lithium. A high power current would flow down the liquid lithium and the resulting Lorentz force would compress the column by roughly a factor of 10. The compressed column would reach criticality and a combination of fission and fusion reactions would occur. Our Phase I results, summarized herein, review our estimates of engine and vehicle performance, our work to date to model the fission-fusion reaction, and our initial efforts in experimental analysis.

  18. A stand-alone compact EUV microscope based on gas-puff target source.

    PubMed

    Torrisi, Alfio; Wachulak, Przemyslaw; Węgrzyński, Łukasz; Fok, Tomasz; Bartnik, Andrzej; Parkman, Tomáš; Vondrová, Šárka; Turňová, Jana; Jankiewicz, Bartłomiej J; Bartosewicz, Bartosz; Fiedorowicz, Henryk

    2017-02-01

    We report on a very compact desk-top transmission extreme ultraviolet (EUV) microscope based on a laser-plasma source with a double stream gas-puff target, capable of acquiring magnified images of objects with a spatial (half-pitch) resolution of sub-50 nm. A multilayer ellipsoidal condenser is used to focus and spectrally narrow the radiation from the plasma, producing a quasi-monochromatic EUV radiation (λ = 13.8 nm) illuminating the object, whereas a Fresnel zone plate objective forms the image. Design details, development, characterization and optimization of the EUV source and the microscope are described and discussed. Test object and other samples were imaged to demonstrate superior resolution compared to visible light microscopy. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.

  19. Pyrolysis and combustion of tobacco in a cigarette smoking simulator under air and nitrogen atmosphere.

    PubMed

    Busch, Christian; Streibel, Thorsten; Liu, Chuan; McAdam, Kevin G; Zimmermann, Ralf

    2012-04-01

    A coupling between a cigarette smoking simulator and a time-of-flight mass spectrometer was constructed to allow investigation of tobacco smoke formation under simulated burning conditions. The cigarette smoking simulator is designed to burn a sample in close approximation to the conditions experienced by a lit cigarette. The apparatus also permits conditions outside those of normal cigarette burning to be investigated for mechanistic understanding purposes. It allows control of parameters such as smouldering and puff temperatures, as well as combustion rate and puffing volume. In this study, the system enabled examination of the effects of "smoking" a cigarette under a nitrogen atmosphere. Time-of-flight mass spectrometry combined with a soft ionisation technique is expedient to analyse complex mixtures such as tobacco smoke with a high time resolution. The objective of the study was to separate pyrolysis from combustion processes to reveal the formation mechanism of several selected toxicants. A purposely designed adapter, with no measurable dead volume or memory effects, enables the analysis of pyrolysis and combustion gases from tobacco and tobacco products (e.g. 3R4F reference cigarette) with minimum aging. The combined system demonstrates clear distinctions between smoke composition found under air and nitrogen smoking atmospheres based on the corresponding mass spectra and visualisations using principal component analysis.

  20. An integrated model-based approach to the risk assessment of pesticide drift from vineyards

    NASA Astrophysics Data System (ADS)

    Pivato, Alberto; Barausse, Alberto; Zecchinato, Francesco; Palmeri, Luca; Raga, Roberto; Lavagnolo, Maria Cristina; Cossu, Raffaello

    2015-06-01

    The inhalation of pesticide in air is of particular concern for people living in close contact with intensive agricultural activities. This study aims to develop an integrated modelling methodology to assess whether pesticides pose a risk to the health of people living near vineyards, and apply this methodology in the world-renowned Prosecco DOCG (Italian label for protection of origin and geographical indication of wines) region. A sample field in Bigolino di Valdobbiadene (North-Eastern Italy) was selected to perform the pesticide fate modellization and the consequent inhalation risk assessment for people living in the area. The modellization accounts for the direct pesticide loss during the treatment of vineyards and for the volatilization from soil after the end of the treatment. A fugacity model was used to assess the volatilization flux from soil. The Gaussian puff air dispersion model CALPUFF was employed to assess the airborne concentration of the emitted pesticide over the simulation domain. The subsequent risk assessment integrates the HArmonised environmental Indicators for pesticide Risk (HAIR) and US-EPA guidelines. In this case study the modelled situation turned to be safe from the point of view of human health in the case of non-carcinogenic compounds, and additional improvements were suggested to further mitigate the effect of the most critical compound.

  1. A System for Studying Facial Nerve Function in Rats through Simultaneous Bilateral Monitoring of Eyelid and Whisker Movements

    PubMed Central

    Heaton, James T.; Kowaleski, Jeffrey M.; Bermejo, Roberto; Zeigler, H. Philip; Ahlgren, David J.; Hadlock, Tessa A.

    2008-01-01

    The occurrence of inappropriate co-contraction of facially innervated muscles in humans (synkinesis) is a common sequela of facial nerve injury and recovery. We have developed a system for studying facial nerve function and synkinesis in restrained rats using non-contact opto-electronic techniques that enable simultaneous bilateral monitoring of eyelid and whisker movements. Whisking is monitored in high spatio-temporal resolution using laser micrometers, and eyelid movements are detected using infrared diode and phototransistor pairs that respond to the increased reflection when the eyelids cover the cornea. To validate the system, eight rats were tested with multiple five-minute sessions that included corneal air puffs to elicit blink and scented air flows to elicit robust whisking. Four rats then received unilateral facial nerve section and were tested at weeks 3–6. Whisking and eye blink behavior occurred both spontaneously and under stimulus control, with no detectable difference from published whisking data. Proximal facial nerve section caused an immediate ipsilateral loss of whisking and eye blink response, but some ocular closures emerged due to retractor bulbi muscle function. The independence observed between whisker and eyelid control indicates that this system may provide a powerful tool for identifying abnormal co-activation of facial zones resulting from aberrant axonal regeneration. PMID:18442856

  2. Photogrammetry of the particle trajectories on DIPOLE WEST Shots 8, 9, 10, and 11. Volume III. Shot 8. Final report, 1 October--31 December 1977

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewey, J.M.; McMillin, D.J.; Trill, D.

    1978-01-01

    This volume describes the photogrammetry and analysis of the particle trajectories in blast waves produced by the simultaneous detonation of two spherical 1080-lb (490-kg) Pentolite charges (DIPOLE WEST Shot 8). One of the charges was positioned at a height of 25 feet above smooth ground, and the second charge 50 feet above the first. Photogrammetrical measurements were made of the trajectories of air particle flow tracers (smoke puffs), which had been placed in a vertical grid at heights ranging from 3 to 58 feet above the ground and at radial distances ranging from 25 to 140 feet from the verticalmore » axis through the charges. From the measured particle trajectories, calculations were made, as described in AD-A058 377. From the shock front times-of-arrival, calculations were made of the shock velocities and, in turn, the peak particle velocities, air densities and hydrostatic overpressure immediately behind each shock. Calculations were also made of the variation with time of the particle velocity, density, hydrostatic overpressure, dynamic pressure, and total pressure at several fixed points. Results, presented both graphically and in tables, are compared to results previously calculated for the same experiment using shock front photogrammetry.« less

  3. Phenotypical changes in a differentiating immortalized bronchial epithelial cell line after exposure to mainstream cigarette smoke and e-cigarette vapor.

    PubMed

    Aufderheide, Michaela; Emura, Makito

    2017-07-05

    3D constructs composed of differentiated immortalized primary normal human bronchial epithelial (NHBE) cells (CL-1548) were repeatedly exposed at the air-liquid interface to non-lethal concentrations of mainstream cigarette smoke (4 cigarettes a day, 5days/week, 8 repetitions in total) and e-cigarette vapor (50 puffs a day, 5 days/week, 8 repetitions in total) to build up a permanent burden on the cells. Samples were taken after 4, 6 and 8 times of repeated smoke exposure and the cultures were investigated using histopathological methods Compared to the clean air-exposed cultures (process control) and incubator control, the aerosol-exposed cultures showed a reduction of ciliated, mucus-producing and club cells. At the end of the exposure phase, we even found metaplastic areas positive for CK13 antibody in the cultures exposed to mainstream cigarette smoke and e-liquid vapor, commonly seen in squamous cells as a marker for non-cornified squamous epithelium. The control cultures (incubator cells) showed no comparable phenotypical changes. In conclusion, our in vitro model presents a valuable tool to study the induction of phenotypical changes after exposure to hazardous airborne material. Copyright © 2017. Published by Elsevier GmbH.

  4. Influence of eye biometrics and corneal micro-structure on noncontact tonometry.

    PubMed

    Jesus, Danilo A; Majewska, Małgorzata; Krzyżanowska-Berkowska, Patrycja; Iskander, D Robert

    2017-01-01

    Tonometry is widely used as the main screening tool supporting glaucoma diagnosis. Still, its accuracy could be improved if full knowledge about the variation of the corneal biomechanical properties was available. In this study, Optical Coherence Tomography (OCT) speckle statistics are used to infer the organisation of the corneal micro-structure and hence, to analyse its influence on intraocular pressure (IOP) measurements. Fifty-six subjects were recruited for this prospective study. Macro and micro-structural corneal parameters as well as subject age were considered. Macro-structural analysis included the parameters that are associated with the ocular anatomy, such as central corneal thickness (CCT), corneal radius, axial length, anterior chamber depth and white-to-white corneal diameter. Micro-structural parameters which included OCT speckle statistics were related to the internal organisation of the corneal tissue and its physiological changes during lifetime. The corneal speckle obtained from OCT was modelled with the Generalised Gamma (GG) distribution that is characterised with a scale parameter and two shape parameters. In macro-structure analysis, only CCT showed a statistically significant correlation with IOP (R2 = 0.25, p<0.001). The scale parameter and the ratio of the shape parameters of GG distribution showed statistically significant correlation with IOP (R2 = 0.19, p<0.001 and R2 = 0.17, p<0.001, respectively). For the studied group, a weak, although significant correlation was found between age and IOP (R2 = 0.053, p = 0.04). Forward stepwise regression showed that CCT and the scale parameter of the Generalised Gamma distribution can be combined in a regression model (R2 = 0.39, p<0.001) to study the role of the corneal structure on IOP. We show, for the first time, that corneal micro-structure influences the IOP measurements obtained from noncontact tonometry. OCT speckle statistics can be employed to learn about the corneal micro-structure and hence, to further calibrate the IOP measurements.

  5. Abdominal symptoms during physical exercise and the role of gastrointestinal ischaemia: a study in 12 symptomatic athletes.

    PubMed

    ter Steege, Rinze W F; Geelkerken, Robert H; Huisman, Ad B; Kolkman, Jeroen J

    2012-10-01

    Gastrointestinal (GI) symptoms during exercise may be caused by GI ischaemia. The authors report their experience with the diagnostic protocol and management of athletes with symptomatic exercise-induced GI ischaemia. The value of prolonged exercise tonometry in the diagnostic protocol of these patients was evaluated. Patients referred for GI symptoms during physical exercise underwent a standardised diagnostic protocol, including prolonged exercise tonometry. Indicators of GI ischaemia, as measured by tonometry, were related to the presence of symptoms during the exercise test (S+ and S- tests) and exercise intensity. 12 athletes were specifically referred for GI symptoms during exercise (five males and seven females; median age 29 years (range 15-46 years)). Type of sport was cycling, long-distance running and triathlon. Median duration of symptoms was 32 months (range 7-240 months). Splanchnic artery stenosis was found in one athlete. GI ischaemia was found in six athletes during submaximal exercise. All athletes had gastric and jejunal ischaemia during maximum intensity exercise. No significant difference was found in gastric and jejunal Pco(2) or gradients between S+ and S- tests during any phase of the exercise protocol. In S+ tests, but not in S- tests, a significant correlation between lactate and gastric gradient was found. In S+ tests, the regression coefficients of gradients were higher than those in S- tests. Treatment advice aimed at limiting GI ischaemia were successful in reducing complaints in the majority of the athletes. GI ischaemia was present in all athletes during maximum intensity exercise and in 50% during submaximal exercise. Athletes with GI symptoms had higher gastric gradients per mmol/l increase in lactate, suggesting an increased susceptibility for the development of ischaemia during exercise. Treatment advice aimed at limiting GI ischaemia helped the majority of the referred athletes to reduce their complaints. Our results suggest an important role for GI ischaemia in the pathophysiology of their complaints.

  6. Influence of eye biometrics and corneal micro-structure on noncontact tonometry

    PubMed Central

    Majewska, Małgorzata; Krzyżanowska-Berkowska, Patrycja; Iskander, D. Robert

    2017-01-01

    Purpose Tonometry is widely used as the main screening tool supporting glaucoma diagnosis. Still, its accuracy could be improved if full knowledge about the variation of the corneal biomechanical properties was available. In this study, Optical Coherence Tomography (OCT) speckle statistics are used to infer the organisation of the corneal micro-structure and hence, to analyse its influence on intraocular pressure (IOP) measurements. Methods Fifty-six subjects were recruited for this prospective study. Macro and micro-structural corneal parameters as well as subject age were considered. Macro-structural analysis included the parameters that are associated with the ocular anatomy, such as central corneal thickness (CCT), corneal radius, axial length, anterior chamber depth and white-to-white corneal diameter. Micro-structural parameters which included OCT speckle statistics were related to the internal organisation of the corneal tissue and its physiological changes during lifetime. The corneal speckle obtained from OCT was modelled with the Generalised Gamma (GG) distribution that is characterised with a scale parameter and two shape parameters. Results In macro-structure analysis, only CCT showed a statistically significant correlation with IOP (R2 = 0.25, p<0.001). The scale parameter and the ratio of the shape parameters of GG distribution showed statistically significant correlation with IOP (R2 = 0.19, p<0.001 and R2 = 0.17, p<0.001, respectively). For the studied group, a weak, although significant correlation was found between age and IOP (R2 = 0.053, p = 0.04). Forward stepwise regression showed that CCT and the scale parameter of the Generalised Gamma distribution can be combined in a regression model (R2 = 0.39, p<0.001) to study the role of the corneal structure on IOP. Conclusions We show, for the first time, that corneal micro-structure influences the IOP measurements obtained from noncontact tonometry. OCT speckle statistics can be employed to learn about the corneal micro-structure and hence, to further calibrate the IOP measurements. PMID:28472178

  7. Comparison of iCare tonometer and Goldmann applanation tonometry in normal corneas and in eyes with automated lamellar and penetrating keratoplasty

    PubMed Central

    Salvetat, M L; Zeppieri, M; Miani, F; Tosoni, C; Parisi, L; Brusini, P

    2011-01-01

    Purpose To compare intraocular pressure (IOP) measurements with Goldmann applanation tonometry (GAT) and iCare tonometry in normal and post-keratoplasty corneas and to assess the influence of central corneal thickness (CCT), corneal curvature (CC), and corneal astigmatism (CA) on IOP. Methods This prospective cross-sectional study included one eye of 101 subjects with normal corneas (58 healthy subjects, 43 glaucoma); and 90 post-keratoplasty patients: 34 penetrating keratoplasties (PK); 20 automated-lamellar-therapeutic keratoplasties (ALTK); 19 Descemet-stripping-automated-endothelial keratoplasties (DSAEK); 17 edematous grafts. All subjects underwent GAT and iCare IOP measurements in random order, and CCT, CC, and CA evaluation. The Bland–Altman method and multivariate regression analysis were used to assess inter-tonometer agreement and the influence of CCT, CC, and CA on IOP. Results iCare significantly underestimated IOP in all groups compared with GAT (GAT minus iCare of 3.5±3.5 mm Hg, P<0.001), but overestimated IOP in the edematous grafts (GAT minus iCare of −6.5±1.9 mm Hg, P<0.001). In normal corneas, both tonometer measurements were directly related to CCT values; iCare readings appeared inversely related to CC. There was no significant relationship between IOP and CCT, CC and CA in post-keratoplasty eyes, except between CC and iCare measurements for PK eyes. Conclusions The agreement between GAT and iCare was clinically acceptable in control, ALTK and DSAEK groups, and poor in PK and edematous grafts eyes. In normal corneas, GAT was significantly affected by CCT; iCare was influenced by CCT and CC. The iCare appeared less influenced by corneal edema when compared with GAT. High IOP readings taken with both tonometers in grafts should raise suspicion of true elevated IOP. PMID:21436848

  8. Comparison of the relative airways and systemic potencies of inhaled fenoterol and salbutamol in asthmatic patients.

    PubMed Central

    Lipworth, B. J.; Newnham, D. M.; Clark, R. A.; Dhillon, D. P.; Winter, J. H.; McDevitt, D. G.

    1995-01-01

    BACKGROUND--There is controversy as to the relative safety of fenoterol and salbutamol. No differences have been found in the relative cardiac beta 1/beta 2 receptor activity of inhaled fenoterol and salbutamol in normal subjects. These initial findings have been extended by comparing the respective potencies of equivalent doses by weight of fenoterol and salbutamol in asthmatic subjects, in terms of airways and systemic responses. METHODS--Eighteen asthmatic patients of mean (SD) age 40 (14) years and a forced expiratory volume in one second (FEV1)% predicted of 56 (14)% (1.97 (0.66)1) were randomised to inhale fenoterol (100 micrograms/puff or 200 micrograms/puff), salbutamol, or placebo (100 micrograms/puff or 200 micrograms/puff) on three separate days. Dose-response curves were constructed using cumulative doses of 100 micrograms, 200 micrograms, 400 micrograms, 1000 micrograms, 2000 micrograms, and 4000 micrograms, and airways and systemic responses were measured 20 minutes after each dose with 40 minute increments. Dose ratios for the relative potency of fenoterol versus salbutamol were calculated from the dose-response curves using regression analysis of parallel slopes. RESULTS--There was no difference in bronchodilator potency between fenoterol and salbutamol (as median dose ratio): FEV1 1.1 (95% CI 0.4 to 4.6). In contrast, dose ratios for systemic responses showed that fenoterol was more potent than salbutamol: serum potassium 3.7 (95% CI 2.0 to 6.0), tremor 5.7 (95% CI 1.4 to 10.2), heart rate 1.6 (95% CI 1.0 to 2.3). At a conventional dose of 200 micrograms the only difference in response between the two drugs was observed for tremor (as mean difference): 0.23 log units (95% CI 0.06 to 0.41 log units). CONCLUSIONS--There was no difference in the bronchodilator potency between fenoterol and salbutamol on a microgram equivalent basis. In contrast, systemic potency was greater with fenoterol, although this difference was not clinically relevant at conventional dosages up to 200 micrograms. PMID:7886650

  9. 'Real-world' compensatory behaviour with low nicotine concentration e-liquid: subjective effects and nicotine, acrolein and formaldehyde exposure.

    PubMed

    Dawkins, Lynne; Cox, Sharon; Goniewicz, Maciej; McRobbie, Hayden; Kimber, Catherine; Doig, Mira; Kośmider, Leon

    2018-06-07

    To compare the effects of i) high versus low nicotine concentration e-liquid, ii) fixed versus adjustable power and iii) the interaction between the two on: a) vaping behaviour, b) subjective effects, c) nicotine intake, and d) exposure to acrolein and formaldehyde in e-cigarette users vaping in their everyday setting. Counterbalanced, repeated measures with four conditions: i) low nicotine (6 mg/mL)/fixed power; ii) low nicotine/adjustable power; iii) high nicotine (18 mg/mL)/fixed power; iv) high nicotine/adjustable power. London and the South East, England. Twenty experienced e-cigarette users (recruited between September 2016 and February 2017) vaped ad libitum using an eVic Supreme™ with a 'Nautilus Aspire' tank over four weeks (one week per condition). Puffing patterns (daily puff number [PN], puff duration [PD], inter-puff interval [IPI]), mL of e-liquid consumed, changes to power (where permitted), and subjective effects (urge to vape, nicotine withdrawal symptoms) were measured in each condition. Nicotine intake was measured via salivary cotinine. 3-hydroxypropylmercapturic acid (3-HPMA), a metabolite of the toxicant acrolein, and formate, a metabolite of the carcinogen formaldehyde, were measured in urine. There was a significant nicotine concentration x power interaction for PD (p<0.01). PD was longer with low nicotine/fixed power compared with i) high nicotine/fixed power (p< 0.001 and ii) low nicotine/adjustable power (p< 0.01). PN and liquid consumed were higher in the low versus high nicotine condition (main effect of nicotine, p<0.05). Urge to vape and withdrawal symptoms were lower, and nicotine intake was higher, in the high nicotine condition (main effects of nicotine: p<0.01). Whilst acrolein levels did not differ, there was a significant nicotine x power interaction for formaldehyde (p<0.05). Use of a lower nicotine concentration e-liquid may be associated with compensatory behaviour (e.g., higher number and duration of puffs) and increases in negative affect, urge to vape, and formaldehyde exposure. This article is protected by copyright. All rights reserved.

  10. Electronic cigarette nicotine delivery can exceed that of combustible cigarettes: a preliminary report.

    PubMed

    Ramôa, Carolina P; Hiler, Marzena M; Spindle, Tory R; Lopez, Alexa A; Karaoghlanian, Nareg; Lipato, Thokozeni; Breland, Alison B; Shihadeh, Alan; Eissenberg, Thomas

    2016-04-01

    Electronic cigarettes (ECIGs) aerosolise a liquid that usually contains propylene glycol and/or vegetable glycerine, flavourants and the dependence-producing drug, nicotine, in various concentrations. This laboratory study examined the relationship between liquid nicotine concentration and plasma nicotine concentration and puffing behaviour in experienced ECIG users. Sixteen ECIG-experienced participants used a 3.3-Volt ECIG battery attached to a 1.5-Ohm dual-coil 'cartomiser' loaded with 1 mL of a flavoured propylene glycol/vegetable glycerine liquid to complete four sessions, at least 2 days apart, that differed by nicotine concentration (0, 8, 18 or 36 mg/mL). In each session, participants completed two 10-puff ECIG-use bouts (30 s puff interval) separated by 60 min. Venous blood was sampled to determine plasma nicotine concentration. Puff duration, volume and average flow rate were measured. Immediately after bout 1, mean plasma nicotine concentration was 5.5 ng/mL (SD=7.7) for 0 mg/mL liquid, with significantly (p<0.05) higher mean concentrations observed for the 8 (mean=17.8 ng/mL, SD=14.6), 18 (mean=25.9 ng/mL, SD=17.5) and 36 mg/mL (mean=30.2 ng/mL; SD=20.0) concentrations; a similar pattern was observed for bout 2. For bout 1, at 36 mg/mL, the mean post- minus pre-bout difference was 24.1 ng/mL (SD=18.3). Puff topography data were consistent with previous results and revealed few reliable differences across conditions. This study demonstrates a relationship between ECIG liquid nicotine concentration and user plasma nicotine concentration in experienced ECIG users. Nicotine delivery from some ECIGs may exceed that of a combustible cigarette. The rationale for this higher level of nicotine delivery is uncertain. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. BREEDING SUPER-EARTHS AND BIRTHING SUPER-PUFFS IN TRANSITIONAL DISKS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Eve J.; Chiang, Eugene, E-mail: evelee@berkeley.edu, E-mail: echiang@astro.berkeley.edu

    The riddle posed by super-Earths (1–4R{sub ⊕}, 2–20M{sub ⊕}) is that they are not Jupiters: their core masses are large enough to trigger runaway gas accretion, yet somehow super-Earths accreted atmospheres that weigh only a few percent of their total mass. We show that this puzzle is solved if super-Earths formed late, as the last vestiges of their parent gas disks were about to clear. This scenario would seem to present fine-tuning problems, but we show that there are none. Ambient gas densities can span many (in one case up to 9) orders of magnitude, and super-Earths can still robustlymore » emerge after ∼0.1–1 Myr with percent-by-weight atmospheres. Super-Earth cores are naturally bred in gas-poor environments where gas dynamical friction has weakened sufficiently to allow constituent protocores to gravitationally stir one another and merge. So little gas is present at the time of core assembly that cores hardly migrate by disk torques: formation of super-Earths can be in situ. The basic picture—that close-in super-Earths form in a gas-poor (but not gas-empty) inner disk, fed continuously by gas that bleeds inward from a more massive outer disk—recalls the largely evacuated but still accreting inner cavities of transitional protoplanetary disks. We also address the inverse problem presented by super-puffs: an uncommon class of short-period planets seemingly too voluminous for their small masses (4–10R{sub ⊕}, 2–6M{sub ⊕}). Super-puffs most easily acquire their thick atmospheres as dust-free, rapidly cooling worlds outside ∼1 AU where nebular gas is colder, less dense, and therefore less opaque. Unlike super-Earths, which can form in situ, super-puffs probably migrated in to their current orbits; they are expected to form the outer links of mean-motion resonant chains, and to exhibit greater water content. We close by confronting observations and itemizing remaining questions.« less

  12. Analysis of 1995 speciated volatile organic compound data in the south central U.S.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sather, M.E.; Kemp, M.G.; Yarbrough, J.W.

    1997-12-31

    An analysis of 1995 speciated volatile organic compound (VOC) data from three areas in the south central US has been performed for Baton Rouge, Louisiana, Houston, Texas, and El Paso, Texas. All three areas are required by the Clean Air Act Amendments of 1990 to collect ambient monitoring data for over 50 VOC species, including ten Clean Air Act Title III toxic compounds, as per the Photochemical Assessment Monitoring Stations (PAMS) requirements. The PAMS program was initiated to provide more detailed VOC data for scientists, modelers, and managers working toward eliminating violations of the ozone National Ambient Air Quality Standardsmore » (NAAQS). This paper presents useful information from a preliminary analysis of the 1995 speciated VOC and related data from Baton Rouge, Houston, and El Paso. All data analyzed were extracted from the US Environmental Protection Agency (EPA) Aerometric Information Retrieval System (AIRS) data base after collection and validation by the states of Louisiana and Texas. Key observations from the analyses include: (1) the presence of propane peaks coincident with ozone peaks during all three ozone episode days at the El Paso site; (2) the dominance of mobile source VOC emissions in the El Paso emission inventory, in contrast to the Baton Rouge and Houston VOC emission inventories, after noting strong correlations between carbon monoxide and major exhaust VOC species of gasoline; and (3) the 1995 ozone episodes at the Houston site were influenced by both morning build-up of ambient VOC concentrations and afternoon puffs of VOC emissions, while the 1995 ozone episodes at the Baton Rouge site were influenced by high early and mid-morning VOC ambient concentrations.« less

  13. Evolution of a new sense for wind in flying phasmids? Afferents and interneurons

    NASA Astrophysics Data System (ADS)

    Hustert, Reinhold; Klug, Rebecca

    2009-12-01

    The evolution of winged stick insects (phasmids) from secondarily wingless ancestors was proposed in recent studies. We explored the cuticle of flying phasmids for wind sensors that could be involved in their flight control, comparable to those known for locusts. Surprisingly, wind-sensitive hairs (wsH) occur on the palps of mouthparts and on the antennae of the winged phasmid Sipyloidea sipylus which can fly in tethered position only when air currents blow over the mouthparts. The present study describes the morphology and major functional properties of these “new” wsH with soft and bulging hair bases which are different from the beaker-like hair bases of the wsH on the cerci of phasmids and the wsH described in other insects. The most sensitive wsH of antennae and palps respond with phasic-tonic afferents to air currents exceeding 0.2 ms-1. The fields of wsH on one side of the animal respond mainly to ventral, lateral, and frontal wind on the ipsilateral side of the head. Afferent inputs from the wsH converge but also diverge to a group of specific interneurons at their branches in the suboesophageal ganglion and can send their integrated input from wsH fields of the palps and antennae to the thoracic central nervous system. Response types of individual wsH-interneurons are either phasic or phasic-tonic to air puffs or constant air currents and also, the receptive fields of individual interneurons differ. We conclude that the “new” wsH system and its interneurons mainly serve to maintain flight activity in airborne phasmids and also, the “new” wsH must have emerged together with the integrating interneurons during the evolution from wingless to the recent winged forms of phasmids.

  14. Smoker Reactivity to Cues: Effects on Craving and on Smoking behavior

    PubMed Central

    Shiffman, Saul; Dunbar, Michael; Kirchner, Thomas; Li, Xiaoxue; Tindle, Hilary; Anderson, Stewart; Scholl, Sarah

    2013-01-01

    We assessed craving and smoking in response to smoking-relevant cues. 207 daily smokers viewed images related to one of six cue sets (cigarettes, positive and negative affect, alcohol, smoking prohibitions, and neutral cues) in separate sessions. Compared to neutral cues, cigarette cues significantly increased craving, and positive affect cues significantly decreased craving. When subjects were then allowed to smoke during continuing cue exposure, cues did not affect the likelihood of smoking or the amount smoked (number of cigarettes, number of puffs, puff time, or increased carbon monoxide). However, craving intensity predicted likelihood of smoking, latency to smoke, and amount smoked, with craving increases after cue exposure making significant independent contributions. Some craving effects were curvilinear, suggesting that they are subject to thresholds and might not be observed under some circumstances. PMID:22708884

  15. Use of vacuum arc plasma guns for a metal puff Z-pinch system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rousskikh, A. G.; Zhigalin, A. S.; Oreshkin, V. I.

    The performance of a metal puff Z-pinch system has been studied experimentally. In this type of system, the initial cylindrical shell 4 cm in diameter was produced by ten plasma guns. Each gun initiates a vacuum arc operating between magnesium electrodes. The net current of the guns was 80 kA. The arc-produced plasma shell was compressed by using a 450-kA, 450-ns driver, and as a result, a plasma column 0.3 cm in diameter was formed. The electron temperature of the plasma reached 400 eV at an average ion concentration of 1.85 {center_dot} 10{sup 18} cm{sup -3}. The power of themore » Mg K-line radiation emitted by the plasma for 15-30 ns was 300 MW/cm.« less

  16. A reassessment study of multi-material-shell gas puff z-pinches as a pulsed neutron source on the sandia ZR

    NASA Astrophysics Data System (ADS)

    Chong, Y. K.; Velikovich, A. L.; Thornhil, J. W.; Giuliani, J. L.; Knapp, P.; Jennings, C.

    2013-10-01

    Over the last few years, numerous 1D and 2D MHD simulation studies of deuterium (D) based double-shell gas-puff Z-pinch implosions driven by the Sandia ZR accelerator have been carried out to assess the Z-pinch as a pulsed thermal fusion neutron source. In these studies, an ad-hoc time-dependent shunt impedance model was used within the external driving circuit model in order to account for the unresolved current loss in the MITL and the load. In this study, we incorporate an improved ZR circuit model recently formulated based on the recent Sandia argon gas-puff experiment circuit data into the multi-material version of the Mach +DDTCRE RMHD code. We reinvestigate the effects of multidimensional structure and nonuniform gradients as well as the outer- and inner-shell material interaction on the implosion physics and dynamics of both D-on-D and argon-on-D Z-pinch loads using the model. Then, we characterize the neutron production performance of the Z-pinch loads as a function of total mass, mass ratio and/or radius toward their optimization as a pulsed thernonuclear neutron source. Work supported by DOE/NNSA. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. DOE's NNSA under contract DE-AC04-94AL85000.

  17. An Observational Study of Group Waterpipe Use in a Natural Environment

    PubMed Central

    2014-01-01

    Introduction: To date research on tobacco smoking with a waterpipe (hookah, narghile, and shisha) has focused primarily on the individual user in a laboratory setting. Yet, waterpipe tobacco smoking is often a social practice that occurs in cafés, homes, and other natural settings. This observational study examined the behavior of waterpipe tobacco smokers and the social and contextual features of waterpipe use among groups in their natural environment. Methods: Trained observers visited urban waterpipe cafés on multiple occasions during an 8-month period. Observations of 241 individual users in naturally formed groups were made on smoking topography (puff frequency, duration, and interpuff interval [IPI]) and engagement in other activities (e.g., food and drink consumption, other tobacco use, and media viewing). Results: Most users were male in group sizes of 3–4 persons, on average, and each table had 1 waterpipe, on average. The predominant social features during observational periods were conversation and nonalcoholic drinking. Greater puff number was associated with smaller group sizes and more waterpipes per group, while longer IPIs were associated with larger group sizes and fewer waterpipes per group. Additionally, greater puff frequency was observed during media viewing and in the absence of other tobacco use. Conclusions: Overall, the results suggest that waterpipe smoking behavior is affected by group size and by certain social activities. Discussion focuses on how these findings enhance our understanding of factors that may influence exposure to waterpipe tobacco smoke toxicants in naturalistic environments. PMID:23943842

  18. Factors Predicting Smoking in a Laboratory-Based Smoking-Choice Task

    PubMed Central

    Bold, Krysten W.; Yoon, Haewon; Chapman, Gretchen B.; McCarthy, Danielle E.

    2013-01-01

    This study aimed to expand the current understanding of smoking maintenance mechanisms by examining how putative relapse risk factors relate to a single behavioral smoking choice using a novel laboratory smoking-choice task. After 12 hours of nicotine deprivation, participants were exposed to smoking cues and given the choice between smoking up to two cigarettes in a 15-minute window or waiting and receiving four cigarettes after a delay of 45 minutes. Greater nicotine dependence, higher impulsivity, and lower distress tolerance were hypothesized to predict earlier and more intensive smoking. Out of 35 participants (n=9 female), 26 chose to smoke with a median time to a first puff of 1.22 minutes (standard deviation=2.62 min, range=0.03–10.62 min). Survival analyses examined latency to first puff, and results indicated that greater pre-task craving and smoking more cigarettes per day were significantly related to smoking sooner in the task. Greater behavioral disinhibition predicted shorter smoking latency in the first two minutes of the task, but not at a delay of more than two minutes. Lower distress tolerance (reporting greater regulation efforts to alleviate distress) was related to more puffs smoked and greater nicotine dependence was related to more time spent smoking in the task. This novel laboratory smoking-choice paradigm may be a useful laboratory analog for the choices smokers make during cessation attempts and may help identify factors that influence smoking lapses. PMID:23421357

  19. Short-term emergency response planning and risk assessment via an integrated modeling system for nuclear power plants in complex terrain

    NASA Astrophysics Data System (ADS)

    Chang, Ni-Bin; Weng, Yu-Chi

    2013-03-01

    Short-term predictions of potential impacts from accidental release of various radionuclides at nuclear power plants are acutely needed, especially after the Fukushima accident in Japan. An integrated modeling system that provides expert services to assess the consequences of accidental or intentional releases of radioactive materials to the atmosphere has received wide attention. These scenarios can be initiated either by accident due to human, software, or mechanical failures, or from intentional acts such as sabotage and radiological dispersal devices. Stringent action might be required just minutes after the occurrence of accidental or intentional release. To fulfill the basic functions of emergency preparedness and response systems, previous studies seldom consider the suitability of air pollutant dispersion models or the connectivity between source term, dispersion, and exposure assessment models in a holistic context for decision support. Therefore, the Gaussian plume and puff models, which are only suitable for illustrating neutral air pollutants in flat terrain conditional to limited meteorological situations, are frequently used to predict the impact from accidental release of industrial sources. In situations with complex terrain or special meteorological conditions, the proposing emergency response actions might be questionable and even intractable to decisionmakers responsible for maintaining public health and environmental quality. This study is a preliminary effort to integrate the source term, dispersion, and exposure assessment models into a Spatial Decision Support System (SDSS) to tackle the complex issues for short-term emergency response planning and risk assessment at nuclear power plants. Through a series model screening procedures, we found that the diagnostic (objective) wind field model with the aid of sufficient on-site meteorological monitoring data was the most applicable model to promptly address the trend of local wind field patterns. However, most of the hazardous materials being released into the environment from nuclear power plants are not neutral pollutants, so the particle and multi-segment puff models can be regarded as the most suitable models to incorporate into the output of the diagnostic wind field model in a modern emergency preparedness and response system. The proposed SDSS illustrates the state-of-the-art system design based on the situation of complex terrain in South Taiwan. This system design of SDSS with 3-dimensional animation capability using a tailored source term model in connection with ArcView® Geographical Information System map layers and remote sensing images is useful for meeting the design goal of nuclear power plants located in complex terrain.

  20. Tongue-Driven Wheelchair Out-Maneuvers the Competition

    MedlinePlus

    ... Human Services National Institutes of Health Creating Biomedical Technologies to Improve Health En Español | Site Map | Staff ... of daily experience using the sip-and-puff technology, which requires inhaling and exhaling through a straw ...

  1. Flavorings significantly affect inhalation toxicity of aerosol generated from electronic nicotine delivery systems (ENDS)

    PubMed Central

    Leigh, Noel J.; Lawton, Ralph I.; Hershberger, Pamela A.; Goniewicz, Maciej L.

    2018-01-01

    Background E-cigarettes or electronic nicotine delivery systems (ENDS) are designed to deliver nicotine-containing aerosol via inhalation. Little is known about the health effects of flavored ENDS aerosol when inhaled. Methods Aerosol from ENDS was generated using a smoking-machine. Various types of ENDS devices or a tank system prefilled with liquids of different flavors, nicotine carrier, variable nicotine concentrations, and with modified battery output voltage were tested. A convenience sample of commercial fluids with flavor names of tobacco, piña colada, menthol, coffee and strawberry were used. Flavoring chemicals were identified using gas chromatography/mass spectrometry. H292 human bronchial epithelial cells were directly exposed to 55 puffs of freshly-generated ENDS aerosol, tobacco smoke, or air (controls) using an air-liquid interface system and the Health Canada intense smoking protocol. The following in vitro toxicological effects were assessed: 1) cell viability, 2) metabolic activity and 3) release of inflammatory mediators (cytokines). Results Exposure to ENDS aerosol resulted in decreased metabolic activity and cell viability and increased release of IL-1β, IL-6, IL-10, CXCL1, CXCL2 and CXCL10 compared to air controls. Cell viability and metabolic activity were more adversely affected by conventional cigarettes than most tested ENDS products. Product type, battery output voltage, and flavors significantly affected toxicity of ENDS aerosol, with a strawberry-flavored product being the most cytotoxic. Conclusions Our data suggest that characteristics of ENDS products, including flavors, may induce inhalation toxicity. Therefore, ENDS users should use the products with caution until more comprehensive studies are performed. PMID:27633767

  2. Noninvasive and continuous blood pressure measurement via superficial temporal artery tonometry.

    PubMed

    Canning, Julia; Helbert, Kendall; Iashin, Grigoriy; Matthews, Jonathan; Yang, Jason; Delano, Margaret K; Sodini, Charles G; Quan Zhang

    2016-08-01

    The measurement of blood pressure is an important cardiovascular health assessment, yet the current set of methodologies is limited in resolution, repeatability, accuracy, simplicity, and safety. This paper presents the design and prototype implementation of a novel and easy-to-use medical device for noninvasive and continuous blood pressure monitoring through tonometry at the superficial temporal artery (STA). The device features a stable form factor inspired by over-ear headphones that adjusts easily from person to person using a combination prismatic and rotational joint. A stepper motor and pressure sensor, built into the device, apply a controlled force to flatten the artery and measure the wearer's blood pressure. The design is fully wireless, using Bluetooth communication to connect to a custom control and monitoring interface on the user's laptop that allows for easy calibration and real-time measurement. Preliminary testing of the device showed a percentage error from a blood pressure cuff mean arterial pressure measurement of 7.7% (7.0 mmHg). This was also compared to a Nexfin vascular unloading device, which showed a percentage error from the blood pressure cuff of 7.3% (6.6 mmHg).

  3. Computational modeling of Krypton gas puffs with tailored mass density profiles on Z

    DOE PAGES

    Jennings, Christopher A.; Ampleford, David J.; Lamppa, Derek C.; ...

    2015-05-18

    Large diameter multi-shell gas puffs rapidly imploded by high current (~20 MA, ~100 ns) on the Z generator of Sandia National Laboratories are able to produce high-intensity Krypton K-shell emission at ~13 keV. Efficiently radiating at these high photon energies is a significant challenge which requires the careful design and optimization of the gas distribution. To facilitate this, we hydrodynamically model the gas flow out of the nozzle and then model its implosion using a 3-dimensional resistive, radiative MHD code (GORGON). This approach enables us to iterate between modeling the implosion and gas flow from the nozzle to optimize radiativemore » output from this combined system. Furthermore, guided by our implosion calculations, we have designed gas profiles that help mitigate disruption from Magneto-Rayleigh–Taylor implosion instabilities, while preserving sufficient kinetic energy to thermalize to the high temperatures required for K-shell emission.« less

  4. High speed movies of turbulence in Alcator C-Mod

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terry, J.L.; Zweben, S.J.; Bose, B.

    2004-10-01

    A high speed (250 kHz), 300 frame charge coupled device camera has been used to image turbulence in the Alcator C-Mod Tokamak. The camera system is described and some of its important characteristics are measured, including time response and uniformity over the field-of-view. The diagnostic has been used in two applications. One uses gas-puff imaging to illuminate the turbulence in the edge/scrape-off-layer region, where D{sub 2} gas puffs localize the emission in a plane perpendicular to the magnetic field when viewed by the camera system. The dynamics of the underlying turbulence around and outside the separatrix are detected in thismore » manner. In a second diagnostic application, the light from an injected, ablating, high speed Li pellet is observed radially from the outer midplane, and fast poloidal motion of toroidal striations are seen in the Li{sup +} light well inside the separatrix.« less

  5. Advances in Dust Detection and Removal for Tokamaks

    NASA Astrophysics Data System (ADS)

    Campos, A.; Skinner, C. H.; Roquemore, A. L.; Leisure, J. O. V.; Wagner, S.

    2008-11-01

    Dust diagnostics and removal techniques are vital for the safe operation of next step fusion devices such as ITER. An electrostatic dust detector[1] developed in the laboratory is being applied to NSTX. In the tokamak environment, large particles or fibres can fall on the grid potentially causing a permanent short. We report on the development of a gas puff system that uses helium to clear such particles from the detector. Experiments with varying nozzle designs, backing pressures, puff durations, and exit flow orientations have obtained an optimal configuration that effectively removes particles from a 25 cm^2 area. Dust removal from next step tokamaks will be required to meet regulatory dust limits. A tripolar grid of fine interdigitated traces has been designed that generates an electrostatic travelling wave for conveying dust particles to a ``drain.'' First trials have shown particle motion in optical microscope images. [1] C. H. Skinner et al., J. Nucl. Mater., 376 (2008) 29.

  6. Streamwise-Localized Solutions with natural 1-fold symmetry

    NASA Astrophysics Data System (ADS)

    Altmeyer, Sebastian; Willis, Ashley; Hof, Björn

    2014-11-01

    It has been proposed in recent years that turbulence is organized around unstable invariant solutions, which provide the building blocks of the chaotic dynamics. In direct numerical simulations of pipe flow we show that when imposing a minimal symmetry constraint (reflection in an axial plane only) the formation of turbulence can indeed be explained by dynamical systems concepts. The hypersurface separating laminar from turbulent motion, the edge of turbulence, is spanned by the stable manifolds of an exact invariant solution, a periodic orbit of a spatially localized structure. The turbulent states themselves (turbulent puffs in this case) are shown to arise in a bifurcation sequence from a related localized solution (the upper branch orbit). The rather complex bifurcation sequence involves secondary Hopf bifurcations, frequency locking and a period doubling cascade until eventually turbulent puffs arise. In addition we report preliminary results of the transition sequence for pipe flow without symmetry constraints.

  7. Interest in marijuana treatment programs among teenage smokers and nonsmokers.

    PubMed

    Sheer, Amy J; Gorelick, David A; Collins, Charles C; Schroeder, Jennifer R; Heishman, Stephen J; Leff, Michelle K; Moolchan, Eric T

    2009-12-01

    Little is known about adolescents' interest in marijuana treatment programs. This question was evaluated by telephone interview in a convenience sample of 575 adolescents responding to advertisements for tobacco research studies. Eighty-one percent of respondents endorsed the need for marijuana treatment programs for adolescents. These adolescents were younger and less likely to smoke tobacco, smoke marijuana, or use alcohol than those not endorsing such a need. Among the 192 marijuana smokers, the 58.8% who endorsed the need for marijuana treatment programs took their first puff of marijuana at a younger age than those who did not endorse the need. Those who were willing to participate in a marijuana treatment program were more likely African American and took their first marijuana puff at a younger age than those not interested in treatment. These findings suggest that most adolescent marijuana smokers endorse the need for and are willing to attend marijuana treatment programs.

  8. Foam For Filtering

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Like nature's honeycomb, foam is a structure of many-sided cells, apparently solid but actually only three percent material and 97 percent air. Foam is made by a heat-producing chemical reaction which expands a plastic material in a manner somewhat akin to the heat-induced rising of a loaf of bread. The resulting structure of interconnected cells is flexible yet strong and extremely versatile in applicati6n. Foam can, for example, be a sound absorber in one form, while in another it allows sound to pass through it. It can be a very soft powder puff material and at the same time a highly abrasive scrubber. A sampling of foam uses includes stereo speaker grilles, applying postage meter ink, filtering lawnmower carburetor air; deadening noise in trucks and tractors, applying cosmetics, releasing fabric softener and antistatic agents in home clothes dryers, painting, filtering factory heating and ventilating systems, shining shoes, polishing cars, sponge-mopping floors, acting as pre-operative surgical scrubbers-the list is virtually limitless. The process by which foam is made produces "windows," thin plastic membranes connecting the cell walls. Windowed foam is used in many applications but for certain others-filtering, for example-it is desirable to have a completely open network. Scott Paper Company's Foam Division, Chester, Pennsylvania, improved a patented method of "removing the windows," to create an open structure that affords special utility in filtering applications. NASA technology contributed to Scott's improvement.

  9. Evaluation of the effect of ammonia on nicotine pharmacokinetics using rapid arterial sampling.

    PubMed

    McKinney, Diana L; Gogova, Maria; Davies, Bruce D; Ramakrishnan, Viswanathan; Fisher, Kelly; Carter, W Hans; Karnes, H Thomas; Garnett, William R; Iyer, Sunil S; Somani, Amit A; Kobal, Gerd; Barr, William H

    2012-05-01

    The nicotine bolus theory states that the dependence-producing potential of cigarettes relates to a rapid increase in nicotine at brain receptor sites. It has been suggested that ammonia, a compound typically found in tobacco products, further increases the amount of nicotine absorbed and its absorption rate. The aim of this study was to determine whether different ammonia yields in cigarettes affected the rate or amount of nicotine absorption from the lungs to arterial circulation. 34 adult smokers received 3 separate puffs from each of 2 test cigarettes with different ammonia yields (ammonia in smoke: 10.1 μg per cigarette vs. 18.9 μg per cigarette), followed by rapid radial arterial blood sampling (maximum one sample per second) with 30 min between puffs. Arterial blood samples were assayed for nicotine by liquid chromatography tandem mass spectrometry. Pharmacokinetic modeling was performed and the two test cigarettes were assessed for bioequivalence. No significant differences were found in area under the curve, C(max), or T((max)) and the 2 test cigarettes were found to be bioequivalent based on 2 one-sided tests at a significance level of 5%. In addition, the zero-order rate constant (k(0)) obtained from the initial slope of the curves and the model-dependent first-order rate constant (k(a)) were not significantly different. This study provides strong evidence that the different ammonia yields of the test cigarettes had no impact on nicotine pharmacokinetics; thus, the ammonia did not increase the rate or amount of nicotine absorption from a puff of cigarette smoke.

  10. I did eat my vegetables. Agreement between parent and child food intake diaries.

    PubMed

    Rangelov, Natalie; Suggs, L Suzanne; Marques-Vidal, Pedro

    2016-12-01

    To assess the level of agreement between children and their parents when reporting a child's food consumption. Cross-sectional study in which children and parents independently completed 7 d food diaries describing the foods and drinks the child consumed at every meal and snack. The association between child and parent reporting was assessed for nineteen food groups using Kendall's tau-b non-parametric correlations, Spearman's rank correlations, kappa coefficients and Lin's concordance measure of agreement. Results were also stratified by gender of the child and his/her grade at school. Households in Ticino, Switzerland, April-June 2014. Two hundred and ninety-nine children aged 6-12 years and one of their parents participated, with 264 providing complete data (35 % completion rate). Results showed a high level of agreement between child and parent reporting. Spearman correlations ranged from 0·55 (sauces) and 0·57 (fatty meat) to 0·80 (fruit), 0·83 (starchy foods) and 0·84 (pastries). All nineteen Spearman correlations were significant at the 0·001 level. Kendall's tau-b correlations ranged from 0·44 (fat meat) to 0·81 (puff pastry). Kappa values showed low to high levels of agreement, ranging from 0·15 (sweets) to 0·77 (puff pastry). Lin's concordance correlation coefficients ranged from 0·39 (whole grains) to 0·86 (puff pastry). When assessing the eating behaviour of children using a 7 d food diary, children's reports might be as reliable as their parents'.

  11. [Role of cerebral hemodynamics in the mechanism of development of acquired myopia in schoolchildren].

    PubMed

    Iastrebtseva, T A; Demidova, T E; Polikarpova, V E

    2008-01-01

    Rheoencephalography was used to study cerebral venous circulation in 199 schoolchildren aged 12-15 years who had emmetropia, pseudomyopia, and myopia. Tonometry was carried out in 39 persons. Cerebral venous hemodynamic dysfunction was more frequently encountered in schoolchildren with myopia than in those with emmetropia. Intraocular pressure was significantly higher only in schoolchildren with high myopia than in the controls.

  12. Fluress, fluorescein and benoxinate: recovery from bacterial contamination.

    PubMed

    Yolton, D P; German, C J

    1980-05-01

    The ability to recover from bacterial contaminations with Staphylococcus auresus and Pseudomonas aeruginosa was determined for three optometric DPAs: Fluress, fluorescein and benoxinate. Results show that Fluress recovers from contamination more rapidly than benoxinate or fluorescein. This ability to recover from contamination and the relative ease of use of Fluress may make it the DPA choice for a number of optometric procedures including applanation tonometry.

  13. Comparison of intraocular pressure during the application of a liquid patient interface (FEMTO LDV Z8) for femtosecond laser-assisted cataract surgery using two different vacuum levels.

    PubMed

    Ebner, Martina; Mariacher, Siegfried; Januschowski, Kai; Boden, Katrin; Seuthe, Anna-Maria; Szurman, Peter; Boden, Karl Thomas

    2017-08-01

    To evaluate intraocular pressure (IOP) using the application of a novel liquid patient interface for femtosecond laser-assisted cataract surgery with the FEMTO LDV Z8. IOP was evaluated in enucleated porcine eyes prior, during and after the application of the Femto LDV Z8 liquid patient interface (Ziemer Ophthalmic Systems, Switzerland) using intracameral cannulation (n=20), intravitreal cannulation (n=20), rebound tonometry (n=20) and indentation tonometry (n=20). Pressure was assessed prior vacuum, during vacuum (30 s, 1 min, 2 min, 3 min) and after releasing the vacuum (1 min and 2 min). Two groups with different predefined vacuum levels (350 mbar, 420 mbar) were investigated. Mean intracameral pressure (±SD) increased during vacuum application from 20 mm Hg to 52.00 mm Hg (±6.35mm Hg; p=0.005) and 45.18 mmHg (±4.34 mm Hg; p=0.005) for the 420 mbar and the 350 mbar vacuum levels, respectively. Mean intravitreal pressure increased from 20 mm Hg to 25.60 mm Hg (±9.85 mm Hg; p=0.058) and 28.10 mm Hg (±2.54 mm Hg; p=0.059) for the 420 mbar and the 350 mbar vacuum levels, respectively. Pressure values from indentation and rebound tonometry were in between intracameral and intravitreal values. Mean intracameral IOP was 18.1% higher (p=0.019) in the 420 mbar group compared with the 350 mbar group. During vacuum application of the liquid patient interface of the Femto LDV Z8 for femtosecond laser-assisted cataract surgery, IOP values were higher in the anterior chamber compared with the intravitreal pressure measurements. The higher predefined vacuum level (350 mbar vs 420 mbar) resulted in significant higher intracameral IOP. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Noncontact quantitative biomechanical characterization of cardiac muscle using shear wave imaging optical coherence tomography

    PubMed Central

    Wang, Shang; Lopez, Andrew L.; Morikawa, Yuka; Tao, Ge; Li, Jiasong; Larina, Irina V.; Martin, James F.; Larin, Kirill V.

    2014-01-01

    We report on a quantitative optical elastographic method based on shear wave imaging optical coherence tomography (SWI-OCT) for biomechanical characterization of cardiac muscle through noncontact elasticity measurement. The SWI-OCT system employs a focused air-puff device for localized loading of the cardiac muscle and utilizes phase-sensitive OCT to monitor the induced tissue deformation. Phase information from the optical interferometry is used to reconstruct 2-D depth-resolved shear wave propagation inside the muscle tissue. Cross-correlation of the displacement profiles at various spatial locations in the propagation direction is applied to measure the group velocity of the shear waves, based on which the Young’s modulus of tissue is quantified. The quantitative feature and measurement accuracy of this method is demonstrated from the experiments on tissue-mimicking phantoms with the verification using uniaxial compression test. The experiments are performed on ex vivo cardiac muscle tissue from mice with normal and genetically altered myocardium. Our results indicate this optical elastographic technique is useful as a noncontact tool to assist the cardiac muscle studies. PMID:25071943

  15. Trigeminal activation using chemical, electrical, and mechanical stimuli.

    PubMed

    Iannilli, E; Del Gratta, C; Gerber, J C; Romani, G L; Hummel, T

    2008-10-15

    Tactile, proprioceptive, and nociceptive information, including also chemosensory functions are expressed in the trigeminal nerve sensory response. To study differences in the processing of different stimulus qualities, we performed a study based on functional magnetic resonance imaging. The first trigeminal branch (ophthalmic nerve) was activated by (a) intranasal chemical stimulation with gaseous CO2 which produces stinging and burning sensations, but is virtually odorless, (b) painful, but not nociceptive specific cutaneous electrical stimulation, and (c) cutaneous mechanical stimulation using air puffs. Eighteen healthy subjects participated (eight men, 10 women, mean age 31 years). Painful stimuli produced patterns of activation similar to what has been reported for other noxious stimuli, namely activation in the primary and secondary somatosensory cortices, anterior cingulate cortex, insular cortex, and thalamus. In addition, analyses indicated intensity-related activation in the prefrontal cortex which was specifically involved in the evaluation of stimulus intensity. Importantly, the results also indicated similarities between activation patterns after intranasal chemosensory trigeminal stimulation and patterns usually found following intranasal odorous stimulation, indicating the intimate connection between these two systems in the processing of sensory information.

  16. Depression moderates smoking behavior in response to a sad mood induction.

    PubMed

    Fucito, Lisa M; Juliano, Laura M

    2009-09-01

    Stress and anxiety have been shown to increase smoking motivation. There is limited experimental data on depressed or sad mood and smoking. This study investigated the effects of two induced moods on smoking behavior. Depression scores were examined as a potential moderator and mood changes were tested as a potential mediator. Smokers (N = 121) were randomly assigned to receive either a sad induction or a neutral induction via standardized film clips. Among participants with higher depression scores, smoking duration and the number of cigarette puffs were greater in response to the sad condition. There was also a marginal interactive effect on the change in expired air carbon monoxide among this subsample; however, no differences in smoking latency or craving were observed. Changes in positive mood partially mediated the effect of condition on smoking behavior among participants with high depression scores. There was no modifying effect of gender or mediating effect of negative mood changes. The results provide preliminary support that decreases in positive mood may have a greater influence on smoking behavior among depression-prone smokers than less psychiatrically vulnerable smokers. 2009 APA, all rights reserved.

  17. Evaluation of electronic cigarette use (vaping) topography and estimation of liquid consumption: implications for research protocol standards definition and for public health authorities' regulation.

    PubMed

    Farsalinos, Konstantinos E; Romagna, Giorgio; Tsiapras, Dimitris; Kyrzopoulos, Stamatis; Voudris, Vassilis

    2013-06-18

    Although millions of people are using electronic cigarettes (ECs) and research on this topic has intensified in recent years, the pattern of EC use has not been systematically studied. Additionally, no comparative measure of exposure and nicotine delivery between EC and tobacco cigarette or nicotine replacement therapy (NRTs) has been established. This is important, especially in the context of the proposal for a new Tobacco Product Directive issued by the European Commission. A second generation EC device, consisting of a higher capacity battery and tank atomiser design compared to smaller cigarette-like batteries and cartomizers, and a 9 mg/mL nicotine-concentration liquid were used in this study. Eighty subjects were recruited; 45 experienced EC users and 35 smokers. EC users were video-recorded when using the device (ECIG group), while smokers were recorded when smoking (SM-S group) and when using the EC (SM-E group) in a randomized cross-over design. Puff, inhalation and exhalation duration were measured. Additionally, the amount of EC liquid consumed by experienced EC users was measured at 5 min (similar to the time needed to smoke one tobacco cigarette) and at 20 min (similar to the time needed for a nicotine inhaler to deliver 4 mg nicotine). Puff duration was significantly higher in ECIG (4.2 ± 0.7 s) compared to SM-S (2.1 ± 0.4 s) and SM-E (2.3 ± 0.5 s), while inhalation time was lower (1.3 ± 0.4, 2.1 ± 0.4 and 2.1 ± 0.4 respectively). No difference was observed in exhalation duration. EC users took 13 puffs and consumed 62 ± 16 mg liquid in 5 min; they took 43 puffs and consumed 219 ± 56 mg liquid in 20 min. Nicotine delivery was estimated at 0.46 ± 0.12 mg after 5 min and 1.63 ± 0.41 mg after 20 min of use. Therefore, 20.8 mg/mL and 23.8 mg/mL nicotine-containing liquids would deliver 1 mg of nicotine in 5 min and 4 mg nicotine in 20 min, respectively. Since the ISO method significantly underestimates nicotine delivery by tobacco cigarettes, it seems that liquids with even higher than 24 mg/mL nicotine concentration would be comparable to one tobacco cigarette. EC use topography is significantly different compared to smoking. Four-second puffs with 20-30 s interpuff interval should be used when assessing EC effects in laboratory experiments, provided that the equipment used does not get overheated. Based on the characteristics of the device used in this study, a 20 mg/mL nicotine concentration liquid would be needed in order to deliver nicotine at amounts similar to the maximum allowable content of one tobacco cigarette (as measured by the ISO 3308 method). The results of this study do not support the statement of the European Commission Tobacco Product Directive that liquids with nicotine concentration of 4 mg/mL are comparable to NRTs in the amount of nicotine delivered to the user.

  18. Development and application of a reactive plume-in-grid model: evaluation over Greater Paris

    NASA Astrophysics Data System (ADS)

    Korsakissok, I.; Mallet, V.

    2010-09-01

    Emissions from major point sources are badly represented by classical Eulerian models. An overestimation of the horizontal plume dilution, a bad representation of the vertical diffusion as well as an incorrect estimate of the chemical reaction rates are the main limitations of such models in the vicinity of major point sources. The plume-in-grid method is a multiscale modeling technique that couples a local-scale Gaussian puff model with an Eulerian model in order to better represent these emissions. We present the plume-in-grid model developed in the air quality modeling system Polyphemus, with full gaseous chemistry. The model is evaluated on the metropolitan Île-de-France region, during six months (summer 2001). The subgrid-scale treatment is used for 89 major point sources, a selection based on the emission rates of NOx and SO2. Results with and without the subgrid treatment of point emissions are compared, and their performance by comparison to the observations on measurement stations is assessed. A sensitivity study is also carried out, on several local-scale parameters as well as on the vertical diffusion within the urban area. Primary pollutants are shown to be the most impacted by the plume-in-grid treatment. SO2 is the most impacted pollutant, since the point sources account for an important part of the total SO2 emissions, whereas NOx emissions are mostly due to traffic. The spatial impact of the subgrid treatment is localized in the vicinity of the sources, especially for reactive species (NOx and O3). Ozone is mostly sensitive to the time step between two puff emissions which influences the in-plume chemical reactions, whereas the almost-passive species SO2 is more sensitive to the injection time, which determines the duration of the subgrid-scale treatment. Future developments include an extension to handle aerosol chemistry, and an application to the modeling of line sources in order to use the subgrid treatment with road emissions. The latter is expected to lead to more striking results, due to the importance of traffic emissions for the pollutants of interest.

  19. Impaired delay and trace eyeblink conditioning in school-age children with fetal alcohol syndrome.

    PubMed

    Jacobson, Sandra W; Stanton, Mark E; Dodge, Neil C; Pienaar, Mariska; Fuller, Douglas S; Molteno, Christopher D; Meintjes, Ernesta M; Hoyme, H Eugene; Robinson, Luther K; Khaole, Nathaniel; Jacobson, Joseph L

    2011-02-01

    Classical eyeblink conditioning (EBC) involves contingent temporal pairing of a conditioned stimulus (e.g., tone) with an unconditioned stimulus (e.g., air puff). Impairment of EBC has been demonstrated in studies of alcohol-exposed animals and in children exposed prenatally at heavy levels. Fetal alcohol syndrome (FAS) was diagnosed by expert dysmorphologists in a large sample of Cape Coloured, South African children. Delay EBC was examined in a new sample of 63 children at 11.3 years, and trace conditioning in 32 of the same children at 12.8 years. At each age, 2 sessions of 50 trials each were administered on the same day; 2 more sessions the next day, for children not meeting criterion for conditioning. Six of 34 (17.6%) children born to heavy drinkers were diagnosed with FAS, 28 were heavily exposed nonsyndromal (HE), and 29 were nonexposed controls. Only 33.3% with FAS and 42.9% of HE met criterion for delay conditioning, compared with 79.3% of controls. The more difficult trace conditioning task was also highly sensitive to fetal alcohol exposure. Only 16.7% of the FAS and 21.4% of HE met criterion for trace conditioning, compared with 66.7% of controls. The magnitude of the effect of diagnostic group on trace conditioning was not greater than the effect on short delay conditioning, findings consistent with recent rat studies. Longer latency to onset and peak eyeblink CR in exposed children indicated poor timing and failure to blink in anticipation of the puff. Extended training resulted in some but not all of the children reaching criterion. These data showing alcohol-related delay and trace conditioning deficits extend our earlier findings of impaired EBC in 5-year-olds to school-age. Alcohol-related impairment in the cerebellar circuitry required for both forms of conditioning may be sufficient to account for the deficit in both tasks. Extended training was beneficial for some exposed children. EBC provides a well-characterized model system for assessment of degree of cerebellar-related learning and memory dysfunction in fetal alcohol exposed children. Copyright © 2010 by the Research Society on Alcoholism.

  20. Impaired delay and trace eyeblink conditioning in school-age children with fetal alcohol syndrome

    PubMed Central

    Jacobson, Sandra W.; Stanton, Mark E.; Dodge, Neil C.; Pienaar, Mariska; Fuller, Douglas S.; Molteno, Christopher D.; Meintjes, Ernesta M.; Hoyme, H. Eugene; Robinson, Luther K.; Khaole, Nathaniel; Jacobson, Joseph L.

    2013-01-01

    Background Classical eyeblink conditioning (EBC) involves contingent temporal pairing of a conditioned stimulus (e.g., tone) with an unconditioned stimulus (e.g., air puff). Impairment of EBC has been demonstrated in studies of alcohol-exposed animals and in children exposed prenatally at heavy levels. Methods Fetal alcohol syndrome (FAS) was diagnosed by expert dysmorphologists in a large sample of Cape Coloured, South African children. Delay EBC was examined in a new sample of 63 children at 11.3 years, and trace conditioning in 32 of the same children at 12.8 years. At each age, two sessions of 50 trials each were administered on the same day; two more sessions the next day, for children not meeting criterion for conditioning. Results 6 of 34 (17.6%) children born to heavy drinkers were diagnosed with FAS, 28 were heavily exposed nonsyndromal (HE), and 29 were non-exposed controls. Only 33.3% with FAS and 42.9% of HE met criterion for delay conditioning, compared with 79.3% of controls. The more difficult trace conditioning task was also highly sensitive to fetal alcohol exposure. Only 16.7% of the FAS and 21.4% of HE met criterion for trace conditioning, compared with 66.7% of controls. The magnitude of the effect of diagnostic group on trace conditioning was not greater than the effect on short delay conditioning, findings consistent with recent rat studies. Longer latency to onset and peak eyeblink CR in exposed children indicated poor timing and failure to blink in anticipation of the puff. Extended training resulted in some but not all of the children reaching criterion. Conclusions These data showing alcohol-related delay and trace conditioning deficits extend our earlier findings of impaired EBC in 5-year-olds to school-age. Alcohol-related impairment in the cerebellar circuitry required for both forms of conditioning may be sufficient to account for the deficit in both tasks. Extended training was beneficial for some exposed children. EBC provides a well-characterized model system for assessment of degree of cerebellar-related learning and memory dysfunction in fetal alcohol exposed children. PMID:21073484

  1. The usefulness of CorvisST Tonometry and the Ocular Response Analyzer to assess the progression of glaucoma

    NASA Astrophysics Data System (ADS)

    Matsuura, Masato; Hirasawa, Kazunori; Murata, Hiroshi; Nakakura, Shunsuke; Kiuchi, Yoshiaki; Asaoka, Ryo

    2017-01-01

    Corneal Visualization Scheimpflug Technology (CST) and Ocular Response Analyzer (ORA) measurements were carried out in 105 eyes of 69 patients with primary open-angle glaucoma. All patients had axial length (AL), central corneal thickness (CCT), intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) and eight visual fields (VF)s with the Humphrey Field Analyzer. VF progression was summarized using a time trend analysis of mean total deviation (mTD) and the association between mTD progression rate and a number of ocular parameters (including CST and ORA measurements) was assessed using mixed linear regression analysis. The optimal model of VF progression selected based on the corrected Akaike Information Criteria (AICc) included ORA’s corneal hysteresis (CH) parameter as well as a number of CST measurements: mTD progression rate = 1.2-0.070 * mean GAT + 0.090 * CH-1.5 * highest concavity deformation amplitude with CST + 9.4 * A1 deformation amplitude with CST-0.05 * A2 length with CST (AICc = 125.8). Eyes with corneas that experience deep indentation at the maximum deformation, shallow indentation at the first applanation and wide indentation at the second applanation in the CST measurement are more likely to experience faster rates of VF progression.

  2. Insights from two industrial hygiene pilot e-cigarette passive vaping studies.

    PubMed

    Maloney, John C; Thompson, Michael K; Oldham, Michael J; Stiff, Charles L; Lilly, Patrick D; Patskan, George J; Shafer, Kenneth H; Sarkar, Mohamadi A

    2016-01-01

    While several reports have been published using research methods of estimating exposure risk to e-cigarette vapors in nonusers, only two have directly measured indoor air concentrations from vaping using validated industrial hygiene sampling methodology. Our first study was designed to measure indoor air concentrations of nicotine, menthol, propylene glycol, glycerol, and total particulates during the use of multiple e-cigarettes in a well-characterized room over a period of time. Our second study was a repeat of the first study, and it also evaluated levels of formaldehyde. Measurements were collected using active sampling, near real-time and direct measurement techniques. Air sampling incorporated industrial hygiene sampling methodology using analytical methods established by the National Institute of Occupational Safety and Health and the Occupational Safety and Health Administration. Active samples were collected over a 12-hr period, for 4 days. Background measurements were taken in the same room the day before and the day after vaping. Panelists (n = 185 Study 1; n = 145 Study 2) used menthol and non-menthol MarkTen prototype e-cigarettes. Vaping sessions (six, 1-hr) included 3 prototypes, with total number of puffs ranging from 36-216 per session. Results of the active samples were below the limit of quantitation of the analytical methods. Near real-time data were below the lowest concentration on the established calibration curves. Data from this study indicate that the majority of chemical constituents sampled were below quantifiable levels. Formaldehyde was detected at consistent levels during all sampling periods. These two studies found that indoor vaping of MarkTen prototype e-cigarette does not produce chemical constituents at quantifiable levels or background levels using standard industrial hygiene collection techniques and analytical methods.

  3. Ultra-high speed OCT allows measurement of intraocular pressure, corneal geometry, and corneal stiffness using a single instrument

    NASA Astrophysics Data System (ADS)

    Singh, Manmohan; Han, Zhaolong; Nair, Achuth; Schill, Alexander; Twa, Michael D.; Larin, Kirill V.

    2018-02-01

    Screening for ocular diseases, such as glaucoma and keratoconus, includes measuring the eye-globe intraocular pressure (IOP) and corneal biomechanical properties. However, currently available clinical tools cannot quantify corneal tissue material parameters, which can provide critical information for detecting diseases and evaluating therapeutic outcomes. Here, we demonstrate measurement of eye-globe IOP, corneal elasticity, and corneal geometry of in situ porcine corneas with a technique termed applanation optical coherence elastography (Appl-OCE) with single instrument. We utilize an ultrafast phase-sensitive optical coherence tomography system comprised of a 4X buffered Fourier domain mode-locked swept source laser with an Ascan rate of 1.5 MHz and a 7.3 kHz resonant scanner. The IOP was measured by imaging the response of in situ porcine corneas to a large force air-puff. As with other noncontact tonometers, the time when the cornea was applanated during the inwards and outwards motion was correlated to a measure air-pressure temporal profile. The IOP was also measured with a commercially available rebound tonometer for comparison. The stiffness of the corneas was assessed by directly imaging and analyzing the propagation of a focused micro air-pulse induced elastic wave, and the corneal geometry was obtained from the OCT structural image. Our results show that corneal thickness decreased as IOP increased, and that corneal stiffness increased with IOP. Moreover, the IOP measurements made by Appl-OCE were more closely correlated with the artificially set IOP than the rebound tonometer, demonstrating the capabilities of Appl-OCE to measure corneal stiffness, eye-globe IOP, and corneal geometry with a single instrument.

  4. Flavourings significantly affect inhalation toxicity of aerosol generated from electronic nicotine delivery systems (ENDS).

    PubMed

    Leigh, Noel J; Lawton, Ralph I; Hershberger, Pamela A; Goniewicz, Maciej L

    2016-11-01

    E-cigarettes or electronic nicotine delivery systems (ENDS) are designed to deliver nicotine-containing aerosol via inhalation. Little is known about the health effects of flavoured ENDS aerosol when inhaled. Aerosol from ENDS was generated using a smoking machine. Various types of ENDS devices or a tank system prefilled with liquids of different flavours, nicotine carrier, variable nicotine concentrations and with modified battery output voltage were tested. A convenience sample of commercial fluids with flavour names of tobacco, piña colada, menthol, coffee and strawberry were used. Flavouring chemicals were identified using gas chromatography/mass spectrometry. H292 human bronchial epithelial cells were directly exposed to 55 puffs of freshly generated ENDS aerosol, tobacco smoke or air (controls) using an air-liquid interface system and the Health Canada intense smoking protocol. The following in vitro toxicological effects were assessed: (1) cell viability, (2) metabolic activity and (3) release of inflammatory mediators (cytokines). Exposure to ENDS aerosol resulted in decreased metabolic activity and cell viability and increased release of interleukin (IL)-1β, IL-6, IL-10, CXCL1, CXCL2 and CXCL10 compared to air controls. Cell viability and metabolic activity were more adversely affected by conventional cigarettes than most tested ENDS products. Product type, battery output voltage and flavours significantly affected toxicity of ENDS aerosol, with a strawberry-flavoured product being the most cytotoxic. Our data suggest that characteristics of ENDS products, including flavours, may induce inhalation toxicity. Therefore, ENDS users should use the products with caution until more comprehensive studies are performed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. Integrating a street-canyon model with a regional Gaussian dispersion model for improved characterisation of near-road air pollution

    NASA Astrophysics Data System (ADS)

    Fallah-Shorshani, Masoud; Shekarrizfard, Maryam; Hatzopoulou, Marianne

    2017-03-01

    The development and use of dispersion models that simulate traffic-related air pollution in urban areas has risen significantly in support of air pollution exposure research. In order to accurately estimate population exposure, it is important to generate concentration surfaces that take into account near-road concentrations as well as the transport of pollutants throughout an urban region. In this paper, an integrated modelling chain was developed to simulate ambient Nitrogen Dioxide (NO2) in a dense urban neighbourhood while taking into account traffic emissions, the regional background, and the transport of pollutants within the urban canopy. For this purpose, we developed a hybrid configuration including 1) a street canyon model, which simulates pollutant transfer along streets and intersections, taking into account the geometry of buildings and other obstacles, and 2) a Gaussian puff model, which resolves the transport of contaminants at the top of the urban canopy and accounts for regional meteorology. Each dispersion model was validated against measured concentrations and compared against the hybrid configuration. Our results demonstrate that the hybrid approach significantly improves the output of each model on its own. An underestimation appears clearly for the Gaussian model and street-canyon model compared to observed data. This is due to ignoring the building effect by the Gaussian model and undermining the contribution of other roads by the canyon model. The hybrid approach reduced the RMSE (of observed vs. predicted concentrations) by 16%-25% compared to each model on its own, and increased FAC2 (fraction of predictions within a factor of two of the observations) by 10%-34%.

  6. Sumo Puff: Tidal debris or disturbed ultra-diffuse galaxy?

    NASA Astrophysics Data System (ADS)

    Greco, Johnny P.; Greene, Jenny E.; Price-Whelan, Adrian M.; Leauthaud, Alexie; Huang, Song; Goulding, Andy D.; Strauss, Michael A.; Komiyama, Yutaka; Lupton, Robert H.; Miyazaki, Satoshi; Takada, Masahiro; Tanaka, Masayuki; Usuda, Tomonori

    2018-01-01

    We report the discovery of a diffuse stellar cloud with an angular extent ≳30″, which we term "Sumo Puff", in data from the Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP). While we do not have a redshift for this object, it is in close angular proximity to a post-merger galaxy at redshift z = 0.0431 and is projected within a few virial radii (assuming similar redshifts) of two other ˜L⋆ galaxies, which we use to bracket a potential redshift range of 0.0055 < z < 0.0431. The object's light distribution is flat, as characterized by a low Sérsic index (n ˜ 0.3). It has a low central g-band surface brightness of ˜26.4 mag arcsec-2, large effective radius of ˜13″ (˜11 kpc at z = 0.0431 and ˜1.5 kpc at z = 0.0055), and an elongated morphology (b/a ˜ 0.4). Its red color (g - i ˜ 1) is consistent with a passively evolving stellar population and similar to the nearby post-merger galaxy, and we may see tidal material connecting Sumo Puff with this galaxy. We offer two possible interpretations for the nature of this object: (1) it is an extreme, galaxy-sized tidal feature associated with a recent merger event, or (2) it is a foreground dwarf galaxy with properties consistent with a quenched, disturbed, ultra-diffuse galaxy. We present a qualitative comparison with simulations that demonstrates the feasibility of forming a structure similar to this object in a merger event. Follow-up spectroscopy and/or deeper imaging to confirm the presence of the bridge of tidal material will be necessary to reveal the true nature of this object.

  7. Differential effects of a body image exposure session on smoking urge between physically active and sedentary female smokers.

    PubMed

    Nair, Uma S; Collins, Bradley N; Napolitano, Melissa A

    2013-03-01

    Smoking is often used as a maladaptive weight control strategy among female smokers. Many of the perceived benefits accrued from smoking, including enhanced mood, reduced anxiety, and weight control, can also be achieved through physical activity. The purpose of this study was to examine the effects of a novel behavioral task (body-image exposure) that was designed to elicit body image and weight concerns on urge to smoke among 18-24 year old female smokers who vary in levels of physical activity. Using a cue-reactivity paradigm, 16 sedentary (SE) and 21 physically active (PA) female smokers (≥5 cigarettes/day for past 6 months) were exposed to a pilot tested body-image exposure session. Self-reported urge and latency to first puff were obtained before and after exposure session. Paired sample t tests showed significant increases in self-reported urge (p < .01) and quicker latency to first puff (p < .01) at posttest for the entire sample compared with pretest. Results of partial correlation (controlling for body mass index [BMI], nicotine dependence, withdrawal, and depressive symptoms) showed that increased time engaging in vigorous intensity physical activity was associated with lower self-reported urge to smoke at post (r = -0.44; p = .01) but not with latency to first puff (r = -.10; p = .62). These results suggest that among weight-concerned female smokers, physical activity may attenuate smoking urges in a context where weight concerns are increased. Future research should continue to explore effects of physical activity on reactivity to body image and smoking cues and variability in smoking cue-reactivity related to physical activity. (PsycINFO Database Record (c) 2013 APA, all rights reserved).

  8. Sex/Gender Differences in Cotinine Levels Among Daily Smokers in the Pennsylvania Adult Smoking Study.

    PubMed

    Chen, Allshine; Krebs, Nicolle M; Zhu, Junjia; Sun, Dongxiao; Stennett, Andrea; Muscat, Joshua E

    2017-11-01

    This study was conducted to determine sex/gender differences in smoke exposure and to quantify the role of potential predictors including puffing behaviors, nicotine dependence, and non-nicotinic factors. The Pennsylvania Adult Smoking Study (PASS) of 332 adult cigarette smokers utilized portable handheld topography devices to capture the smokers' profiles in a naturalistic environment. Sex/gender differences in salivary biomarkers were modeled using ANCOVA to account for measures of dependence (Fagerstrom Test for Nicotine Dependence, nicotine metabolite ratio [3-hydroxycotinine/cotinine]), and nondependence covariates including anthropomorphic factors and stress. The Blinder-Oaxaca method was used to decompose the sex/gender differences in nicotine uptake due to covariates. Men had significantly higher cotinine levels (313.5 ng/mL vs. 255.8 ng/mL, p < 0.01), cotinine +3-hydroxycotinine levels, (0.0787 mol/L vs. 0.0675 mol/L, p = 0.01), puff volumes (52.95 mL vs. 44.77 mL, p < 0.01), and a lower nicotine metabolite ratio (0.396 vs. 0.475, p = 0.01) than women. The mean Fagerström Test for Nicotine Dependence score did not differ between men and women (p = 0.24). Women had a higher mean Hooked on Tobacco Checklist score than men (7.64 vs. 6.87, p < 0.01). In multivariate analysis, nicotine metabolite levels were not significantly different by sex. Decomposition results show that ten predictors can explain 83% of the sex/gender differences in cotinine uptake. Height was the greatest contributor to these differences, followed by average puff volume. Conclusion and Impact: The higher levels of nicotine metabolites in men, compared to women, can be explained by height, weight, puff volume, and nicotine metabolism.

  9. Tar, CO and delta 9THC delivery from the 1st and 2nd halves of a marijuana cigarette.

    PubMed

    Tashkin, D P; Gliederer, F; Rose, J; Chang, P; Hui, K K; Yu, J L; Wu, T C

    1991-11-01

    Previous in vitro studies suggest that, with successive puffs from a marijuana cigarette, delta-9-THC becomes concentrated in the remaining uncombusted portion of the cigarette. These observations are consistent with the common practice of smoking marijuana cigarettes to a smaller butt length than that to which tobacco cigarettes are smoked. The purpose of the present study was to compare the delivery of delta-9-THC, as well as total insoluble smoke particulates (tar) and carbon monoxide, from the distal ("first") versus the proximal ("second") halves of a standard marijuana cigarette during "natural" smoking of marijuana. On 4 separate days, ten habitual marijuana users smoked nearly all or approximately 1/2 of a standard marijuana cigarette (83 mm length; 800-900 mg; 1.24% THC), as follows: day 1, "whole" cigarette (60 mm smoked, leaving a 23-mm butt); day 2, "first" half (first 30 mm); day 3, "second" half (second 30 mm) after the "first" half was presmoked with a syringe; and day 4, "second" half after the "first" half was excised. A previously described smoking apparatus (20) was used for measurement of puff volume and inhaled tar. Puff volume and number were allowed to vary spontaneously (provided that the specified length of cigarette was consumed), while inhaled volume (1.5 liters), breathholding time (14 s) and interpuff interval (30 s) were held constant. Blood samples were withdrawn prior to smoking and serially after completion of smoking for analysis of blood carboxyhemoglobin (COHb) and serum delta-9-THC. Heart rate was measured before and 5 min after smoking. Subjects rated their level of "high" 20 min after completion of smoking.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. The effects of nicotine stimulus and response expectancies on male and female smokers' responses to nicotine-free electronic cigarettes.

    PubMed

    Copp, Sebastian R; Collins, Jamie L; Dar, Reuven; Barrett, Sean P

    2015-01-01

    Electronic cigarettes (e-cigarettes) have been reported to reduce tobacco craving and withdrawal; however, the mechanisms underlying these effects have not been elucidated. This study examined the contributions of nicotine stimulus and response expectancies to responses to nicotine-free e-cigarettes in 21 e-cigarette naïve smokers (12 male). Participants completed two randomized experimental sessions in which they administered a nicotine-free e-cigarette. During one session they were informed that the e-cigarette contained nicotine and during the other session they were informed that the e-cigarette was nicotine-free. Participants completed subjective assessments before and immediately after sampling ten puffs from the e-cigarette and were then invited to earn additional puffs using a computerized progressive ratio task. Prior to their enrolment in the study, participants provided an estimate of the relative importance of the nicotine content of e-cigarettes for craving relief. Instructions that the e-cigarette contained nicotine were found to reduce both intention to smoke (p=0.017) and withdrawal-related (p=0.018) craving, regardless of a-priori reported beliefs regarding the relative importance of nicotine. Nicotine content instructions were also found to be associated with a shorter latency to self-administration (p=0.005); however, a Sex×Instructions×Response Expectancy interaction (p=0.008) revealed that this effect was specific to women who had strong a-priori nicotine content craving relief expectations. Neither nicotine content instructions nor response expectancies impacted the number of puffs self-administered. Findings suggest that nicotine content expectations contribute to smokers' responses to e-cigarettes, and that a-priori beliefs about nicotine effects may be especially important in women. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Protocol proposal for, and evaluation of, consistency in nicotine delivery from the liquid to the aerosol of electronic cigarettes atomizers: regulatory implications.

    PubMed

    Farsalinos, Konstantinos E; Yannovits, Nikoletta; Sarri, Theoni; Voudris, Vassilis; Poulas, Konstantinos

    2016-06-01

    To propose a protocol and evaluate the consistency in nicotine delivery to the aerosol of different types of electronic cigarette (EC) atomizers, as required by regulatory authorities. Three cartomizer and four tank-type atomizer products were tested (three samples per product). The aerosol from three 20-puff sessions from each sample was collected using a smoke machine. Three cartridges from a nicotine inhaler and three tobacco cigarettes were also tested. Analytical laboratory in Greece. Aerosol nicotine levels were measured. Relative standard deviation (RSD, i.e. coefficient of variation) was calculated separately for each cartomizer and replacement atomizer head sample (intrasample RSD) and between different samples (intersample RSD). The percentage difference from the mean, which is used to assess the quality of medicinal nebulizers, was also calculated. The aerosol nicotine levels were 1.01-10.61 mg/20 puffs for ECs, 0.12-0.18 mg/20 puffs for the nicotine inhaler and 1.76-2.20 mg/cigarette for the tobacco cigarettes. The intrasample RSDs were 3.7-12.5% for ECs and 14.3% for the nicotine inhaler and 11.1% for the tobacco cigarettes. The intersample RSDs were higher in cartomizers (range: 6.9-37.8%) compared with tank systems (range: 6.4-9.3%). All tank-type atomizers and one cartomizer were within 75-125% of the mean, as dictated for medicinal nebulizers. Electronic cigarettes that use tank-type atomizers appear to deliver nicotine in more consistent quantities (within the acceptable limits for medicinal nebulizers and similar to the nicotine inhaler) than electronic cigarettes that use cartomizers. The protocol for testing nicotine delivery consistency described in this paper could be used effectively for regulatory purposes. © 2016 Society for the Study of Addiction.

  12. Intense Pulsed Heavy Ion Beam Technology

    NASA Astrophysics Data System (ADS)

    Masugata, Katsumi; Ito, Hiroaki

    Development of intense pulsed heavy ion beam accelerator technology is described for the application of materials processing. Gas puff plasma gun and vacuum arc discharge plasma gun were developed as an active ion source for magnetically insulated pulsed ion diode. Source plasma of nitrogen and aluminum were successfully produced with the gas puff plasma gun and the vacuum arc plasma gun, respectively. The ion diode was successfully operated with gas puff plasma gun at diode voltage 190 kV, diode current 2.2 kA and nitrogen ion beam of ion current density 27 A/cm2 was obtained. The ion composition was evaluated by a Thomson parabola spectrometer and the purity of the nitrogen ion beam was estimated to be 86%. The diode also operated with aluminum ion source of vacuum arc plasma gun. The ion diode was operated at 200 kV, 12 kA, and aluminum ion beam of current density 230 A/cm2 was obtained. The beam consists of aluminum ions (Al(1-3)+) of energy 60-400 keV, and protons (90-130 keV), and the purity was estimated to be 89 %. The development of the bipolar pulse accelerator (BPA) was reported. A double coaxial type bipolar pulse generator was developed as the power supply of the BPA. The generator was tested with dummy load of 7.5 ohm, bipolar pulses of -138 kV, 72 ns (1st pulse) and +130 kV, 70 ns (2nd pulse) were succesively generated. By applying the bipolar pulse to the drift tube of the BPA, nitrogen ion beam of 2 A/cm2 was observed in the cathode, which suggests the bipolar pulse acceleration.

  13. Simulations of Ar gas-puff Z-pinch radiation sources with double shells and central jets on the Z generator

    NASA Astrophysics Data System (ADS)

    Tangri, V.; Harvey-Thompson, A. J.; Giuliani, J. L.; Thornhill, J. W.; Velikovich, A. L.; Apruzese, J. P.; Ouart, N. D.; Dasgupta, A.; Jones, B.; Jennings, C. A.

    2016-10-01

    Radiation-magnetohydrodynamic simulations using the non-local thermodynamic equilibrium Mach2-Tabular Collisional-Radiative Equilibrium code in (r, z) geometry are performed for two pairs of recent Ar gas-puff Z-pinch experiments on the refurbished Z generator with an 8 cm diameter nozzle. One pair of shots had an outer-to-inner shell mass ratio of 1:1.6 and a second pair had a ratio of 1:1. In each pair, one of the shots had a central jet. The experimental trends in the Ar K-shell yield and power are reproduced in the calculations. However, the K-shell yield and power are significantly lower than the other three shots for the case of a double-shell puff of 1:1 mass ratio and no central jet configuration. Further simulations of a hypothetical experiment with the same relative density profile of this configuration, but higher total mass, show that the coupled energy from the generator and the K-shell yield can be increased to levels achieved in the other three configurations, but not the K-shell power. Based on various measures of effective plasma radius, the compression in the 1:1 mass ratio and no central jet case is found to be less because the plasma inside the magnetic piston is hotter and of lower density. Because of the reduced density, and the reduced radiation cooling (which is proportional to the square of the density), the core plasma is hotter. Consequently, for the 1:1 outer-to-inner shell mass ratio, the load mass controls the yield and the center jet controls the power.

  14. Nutrition Research.

    DTIC Science & Technology

    1983-10-01

    occurring" sugars 48% Refined and processed sugars 10% Total Fat Saturated fat 10% Poly-unsaturated fat 10% Mono-unsaturated fat 10% 30% Protein 12% 300% i 3...2120 Coffee, Black 2125 Coffee, Decaffeinated 2150 Coleslaw, French or CKD Salad Dressing 2540 Cream Puffs/Eclairs with Custard Filling 2715 Doughnut

  15. Application of Laser Plasma Sources of Soft X-rays and Extreme Ultraviolet (EUV) in Imaging, Processing Materials and Photoionization Studies

    NASA Astrophysics Data System (ADS)

    Fiedorowicz, H.; Bartnik, A.; Wachulak, P. W.; Jarocki, R.; Kostecki, J.; Szczurek, M.; Ahad, I. U.; Fok, T.; Szczurek, A.; Wȩgrzyński, Ł.

    In the paper we present new applications of laser plasma sources of soft X-rays and extreme ultraviolet (EUV) in various areas of plasma physics, nanotechnology and biomedical engineering. The sources are based on a gas puff target irradiated with nanosecond laser pulses from commercial Nd: YAG lasers, generating pulses with time duration from 1 to 10 ns and energies from 0.5 to 10 J at a 10 Hz repetition rate. The targets are produced with the use of a double valve system equipped with a special nozzle to form a double-stream gas puff target which allows for high conversion efficiency of laser energy into soft X-rays and EUV without degradation of the nozzle. The sources are equipped with various optical systems to collect soft X-ray and EUV radiation and form the radiation beam. New applications of these sources in imaging, including EUV tomography and soft X-ray microscopy, processing of materials and photoionization studies are presented.

  16. Effect of technological factors on water activity of extruded corn product with an addition of whey proteins.

    PubMed

    Makowska, Agnieszka; Cais-Sokolińska, Dorota; Lasik, Agata

    2014-01-01

    The value of water activity in extruded products constitutes a significant indicator of their quality and stability. The state, in which water is found in extruded products, is an indicator of the conducted extrusion process and the used raw material. The aim of the study was to assess water activity in extruded products made from a mixture of com grits with 12.5 and 15.0% moisture contents and different level of addition of whey proteins. It was shown that the degree of mixture moisture content did not have an effect on the value of aw in produced puffs. The greatest difference was recorded when introducing 3% proteins in comparison to aw of puffs produced solely from corn grits. Δaw = 0.023. The greater the content of whey proteins, the lower the aw value. A 3-month storage at a temperature of 18 ±0.5°C influenced aw of snacks produced from a mixture with a higher moisture content.

  17. Injector design for liner-on-target gas-puff experiments

    NASA Astrophysics Data System (ADS)

    Valenzuela, J. C.; Krasheninnikov, I.; Conti, F.; Wessel, F.; Fadeev, V.; Narkis, J.; Ross, M. P.; Rahman, H. U.; Ruskov, E.; Beg, F. N.

    2017-11-01

    We present the design of a gas-puff injector for liner-on-target experiments. The injector is composed of an annular high atomic number (e.g., Ar and Kr) gas and an on-axis plasma gun that delivers an ionized deuterium target. The annular supersonic nozzle injector has been studied using Computational Fluid Dynamics (CFD) simulations to produce a highly collimated (M > 5), ˜1 cm radius gas profile that satisfies the theoretical requirement for best performance on ˜1-MA current generators. The CFD simulations allowed us to study output density profiles as a function of the nozzle shape, gas pressure, and gas composition. We have performed line-integrated density measurements using a continuous wave (CW) He-Ne laser to characterize the liner gas density. The measurements agree well with the CFD values. We have used a simple snowplow model to study the plasma sheath acceleration in a coaxial plasma gun to help us properly design the target injector.

  18. Injector design for liner-on-target gas-puff experiments.

    PubMed

    Valenzuela, J C; Krasheninnikov, I; Conti, F; Wessel, F; Fadeev, V; Narkis, J; Ross, M P; Rahman, H U; Ruskov, E; Beg, F N

    2017-11-01

    We present the design of a gas-puff injector for liner-on-target experiments. The injector is composed of an annular high atomic number (e.g., Ar and Kr) gas and an on-axis plasma gun that delivers an ionized deuterium target. The annular supersonic nozzle injector has been studied using Computational Fluid Dynamics (CFD) simulations to produce a highly collimated (M > 5), ∼1 cm radius gas profile that satisfies the theoretical requirement for best performance on ∼1-MA current generators. The CFD simulations allowed us to study output density profiles as a function of the nozzle shape, gas pressure, and gas composition. We have performed line-integrated density measurements using a continuous wave (CW) He-Ne laser to characterize the liner gas density. The measurements agree well with the CFD values. We have used a simple snowplow model to study the plasma sheath acceleration in a coaxial plasma gun to help us properly design the target injector.

  19. Renovation of the hot press in the Plutonium Experimental Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Congdon, J.W.; Nelson, G.H.

    1990-03-05

    The Plutonium Experimental Facility (PEF) will be used to develop a new fuel pellet fabrication process and to evaluate equipment upgrades. The facility was used from 1978 until 1982 to optimize the parameters for fuel pellet production using a process which was developed at Los Alamos National Laboratory. The PEF was shutdown and essentially abandoned until mid-1987 when the facility renovations were initiated by the Actinide Technology Section (ATS) of SRL. A major portion of the renovation work was related to the restart of the hot press system. This report describes the renovations and modifications which were required to restartmore » the PEF hot press. The primary purpose of documenting this work is to help provide a basis for Separations to determine the best method of renovating the hot press in the Plutonium Fuel Fabrication (PuFF) facility. This report also includes several SRL recommendations concerning the renovation and modification of the PuFF hot press. 4 refs.« less

  20. Neutron production in deuterium gas-puff z-pinch with outer plasma shell at current of 3 MA

    NASA Astrophysics Data System (ADS)

    Cikhardt, J.; Klir, D.; Rezac, K.; Cikhardtova, B.; Kravarik, J.; Kubes, P.; Sila, O.; Shishlov, A. V.; Cherdizov, R. K.; Frusov, F. I.; Kokshenev, V. A.; Kurmaev, N. E.; Labetsky, A. Yu.; Ratakhin, N. A.; Dudkin, G. N.; Garapatsky, A. A.; Padalko, V. N.; Varlachev, V. A.; Turek, K.; Krasa, J.

    2015-11-01

    Z-pinch experiments at the current of about 3 MA were carried out on the GIT-12 generator. The outer plasma shell of deuterium gas-puff was generated by the system of 48 plasma guns. This configuration exhibits a high efficiency of the production of DD fusion neutrons with the yield of above 1012 neutrons produced in a single shot with the duration of about 20 ns. The maximum energy of the neutrons produced in this pulse exceeded 30 MeV. The neutron radiation was measured using scintillation TOF detectors, CR-39 nuclear track detectors, bubble detectors BD-PND and BDS-10000 and by several types of nuclear activation detectors. These diagnostic tools were used to measure the anisotropy of neutron fluence and neutron energy spectra. It allows us to estimate the total number of DD neutrons, the contribution of other nuclear reactions, the amount of scattered neutrons, and other parameters of neutron production. This work was supported by the MSMT grants LH13283, LD14089.

  1. A fast rise-rate, adjustable-mass-bit gas puff valve for energetic pulsed plasma experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loebner, Keith T. K., E-mail: kloebner@stanford.edu; Underwood, Thomas C.; Cappelli, Mark A.

    2015-06-15

    A fast rise-rate, variable mass-bit gas puff valve based on the diamagnetic repulsion principle was designed, built, and experimentally characterized. The ability to hold the pressure rise-rate nearly constant while varying the total overall mass bit was achieved via a movable mechanical restrictor that is accessible while the valve is assembled and pressurized. The rise-rates and mass-bits were measured via piezoelectric pressure transducers for plenum pressures between 10 and 40 psig and restrictor positions of 0.02-1.33 cm from the bottom of the linear restrictor travel. The mass-bits were found to vary linearly with the restrictor position at a given plenummore » pressure, while rise-rates varied linearly with plenum pressure but exhibited low variation over the range of possible restrictor positions. The ability to change the operating regime of a pulsed coaxial plasma deflagration accelerator by means of altering the valve parameters is demonstrated.« less

  2. Evaluation of Surface Modification as a Lunar Dust Mitigation Strategy for Thermal Control Surfaces

    NASA Technical Reports Server (NTRS)

    Gaier, James R.; Waters, Deborah L.; Misconin, Robert M.; Banks, Bruce A.; Crowder, Mark

    2011-01-01

    Three surface treatments were evaluated for their ability to lower the adhesion between lunar simulant dust and AZ93, AlFEP, and AgFEP thermal control surfaces under simulated lunar conditions. Samples were dusted in situ and exposed to a standardized puff of nitrogen gas. Thermal performance before dusting, after dusting, and after part of the dust was removed by the puff of gas, were compared to perform the assessment. None of the surface treatments was found to significantly affect the adhesion of lunar simulants to AZ93 thermal control paint. Oxygen ion beam texturing also did not lower the adhesion of lunar simulant dust to AlFEP or AgFEP. But a workfunction matching coating and a proprietary Ball Aerospace surface treatment were both found to significantly lower the adhesion of lunar simulants to AlFEP and AgFEP. Based on these results, it is recommended that all these two techniques be further explored as dust mitigation coatings for AlFEP and AgFEP thermal control surfaces.

  3. Optimal redistribution of an urban air quality monitoring network using atmospheric dispersion model and genetic algorithm

    NASA Astrophysics Data System (ADS)

    Hao, Yufang; Xie, Shaodong

    2018-03-01

    Air quality monitoring networks play a significant role in identifying the spatiotemporal patterns of air pollution, and they need to be deployed efficiently, with a minimum number of sites. The revision and optimal adjustment of existing monitoring networks is crucial for cities that have undergone rapid urban expansion and experience temporal variations in pollution patterns. The approach based on the Weather Research and Forecasting-California PUFF (WRF-CALPUFF) model and genetic algorithm (GA) was developed to design an optimal monitoring network. The maximization of coverage with minimum overlap and the ability to detect violations of standards were developed as the design objectives for redistributed networks. The non-dominated sorting genetic algorithm was applied to optimize the network size and site locations simultaneously for Shijiazhuang city, one of the most polluted cities in China. The assessment on the current network identified the insufficient spatial coverage of SO2 and NO2 monitoring for the expanding city. The optimization results showed that significant improvements were achieved in multiple objectives by redistributing the original network. Efficient coverage of the resulting designs improved to 60.99% and 76.06% of the urban area for SO2 and NO2, respectively. The redistributing design for multi-pollutant including 8 sites was also proposed, with the spatial representation covered 52.30% of the urban area and the overlapped areas decreased by 85.87% compared with the original network. The abilities to detect violations of standards were not improved as much as the other two objectives due to the conflicting nature between the multiple objectives. Additionally, the results demonstrated that the algorithm was slightly sensitive to the parameter settings, with the number of generations presented the most significant effect. Overall, our study presents an effective and feasible procedure for air quality network optimization at a city scale.

  4. Muscarinic agonists and ATP increase the intracellular Ca2+ concentration in chick cochlear hair cells.

    PubMed

    Shigemoto, T; Ohmori, H

    1990-01-01

    1. Cholinergic muscarinic agonists applied by the pressure puff method increased intracellular Ca2+ concentration in Fura-2-loaded hair cells. The Ca2+ response outlasted the agonist application. 2. The Ca2+ response induced by acetylcholine (ACh) was ACh dose dependent with a KD of 200 microM. Desensitization was negligible, and almost identical Ca2+ responses were observed when two ACh puffs were separated by 150 s. The response was blocked by d-tubocurarine (dTC). The KD of dTC blocking was 500 microM when 100 microM-ACh induced the Ca2+ response. 3. The amplitude of the ACh-induced Ca2+ responses were potentiated to 3 times the control by incubation with calcitonin gene-related peptide (CGRP; 0.1-1 microM). CGRP did not affect the resting Ca2+ concentration. Glycine (100 microM) potentiated the ACh response to 1.4 times the control, and also increased the resting Ca2+ concentration slightly. 4. The ACh-induced Ca2+ response was suppressed by atropine. It was induced in Ca2(+)-free extracellular medium, and in Ca2(+)-free medium desensitization to a second ACh stimulation was significant. The amplitude of the second Ca2+ response was 44% of the first when two ACh puffs were separated by 117 s in Ca2+ free medium. 5. Muscarine and carbamylcholine induced similar Ca2+ responses, with KD values of 130 microM for muscarine and 340 microM for carbamylcholine. Desensitization of Ca2+ responses was negligible in both agonists. 6. ATP co-exists with ACh in some presynaptic nerve terminals (Burnstock, 1981). Puff-applied ATP (100 microM) generated a Ca2+ response with a rapid rising phase and a following slow phase. In Ca2(+)-free medium the rapid phase disappeared and only the slow phase was observed. The rapid phase is due to the influx of Ca2+ ions and the slow phase is due to a release of Ca2+ ions from an intracellular reservoir. Under voltage clamp ATP induced a fast inward current and a following slow outward current. 7. Nicotine, adenosine, glycine, GABA, glutamate and bradykinin did not induce Ca2+ responses in the hair cell. 8. ACh induced hyperpolarization of the hair cell membrane under current clamp, most probably by the activation of Ca2+ activated K+ conductance. Therefore, a cholinergic muscarinic receptor may mediate the inhibitory effects of efferent innervation observed in hair cells.

  5. Inhaled beclomethasone dipropionate improves acoustic measures of voice in patients with asthma.

    PubMed

    Balter, M S; Adams, S G; Chapman, K R

    2001-12-01

    Inhaled corticosteroids have the potential to produce upper-airway side effects such as hoarseness. As new compounds and delivery devices are developed and compared, it is difficult to quantify their adverse upper-airway effects. We undertook the following study to test the ability of an acoustic analysis technique to quantify changes in vocal function in steroid-naive patients with asthma who receive inhaled beclomethasone dipropionate (BDP), 1,000 microg/d for 4 months. Patients self-administered one of four regimens of inhaled BDP. Group 1 patients received one 250-microg puff qid via metered-dose inhaler (MDI); group 2 patients received one 250-microg puff qid via MDI with a holding chamber; group 3 patients received two 250-microg puffs bid via MDI; and group 4 patients received two 250-microg puffs bid via MDI with a holding chamber. A smaller cohort of nonsmoking asthmatic patients was managed without steroid intervention for 4 months. At baseline and again at 8 weeks and 16 weeks after the initiation of BDP treatment, patients underwent spirometry and methacholine challenge. At baseline and again at 2, 4, 8, 12, and 16 weeks, patients underwent voice recording for analysis of voice parameters. The recorded vowels were low-pass filtered (10 KHz), digitized (22 KHz), and analyzed by software to obtain two acoustic measures: (1) jitter, the cycle-to-cycle variation in the time period of the voice signal; and (2) shimmer, the cycle-to-cycle variation in voice signal amplitude. We recruited 77 patients for randomization to inhaled steroid therapy and 10 patients who continued to receive only occasional inhaled bronchodilator therapy. In all active treatment groups, FEV(1), FVC, and provocative concentration of methacholine causing a 20% fall in FEV(1) improved significantly after BDP treatment. Mean jitter scores, a measurement of variation in voice pitch, were not significantly influenced by BDP treatment. However, mean shimmer scores, a reflection of perturbation in vocal amplitude, fell significantly (p < 0.05) in the active treatment groups. These reductions in shimmer scores were not significantly different in the active treatment groups. Shimmer scores in the bronchodilator-treated group were unchanged during the 16 weeks of follow-up. Our data show that a simple and noninvasive acoustic analysis of voice is sensitive to subclinical changes associated with inhaled corticosteroid therapy. We have shown that 1,000 microg/d of inhaled BDP actually improves specific acoustic measures of voice in patients with inadequately controlled asthma. These improvements were uninfluenced by dosing schedule and whether a spacing chamber was used.

  6. Conductive Atomic Force Microscopy | Materials Science | NREL

    Science.gov Websites

    electrical measurement techniques is the high spatial resolution. For example, C-AFM measurements on : High-resolution image of a sample semiconductor device; the image shows white puff-like clusters on a dark background and was obtained using atomic force microscopy. Bottom: High-resolution image of the

  7. Getting a Puff: A Social Learning Test of Adolescents Smoking

    ERIC Educational Resources Information Center

    Monroe, Jacquelyn

    2004-01-01

    This article is a description of a study that sought to examine the applicability of Ronald Akers' social learning theory. According to Akers' theory, differential associations with smokers, differential reinforcements for smoking, favorable definitions of smoking and the availability of role models (imitation) offer an explanation as to why…

  8. EVALUATION AND SENSITIVITY ANALYSES RESULTS OF THE MESOPUFF II MODEL WITH CAPTEX MEASUREMENTS

    EPA Science Inventory

    The MESOPUFF II regional Lagrangian puff model has been evaluated and tested against measurements from the Cross-Appalachian Tracer Experiment (CAPTEX) data base in an effort to assess its abilIty to simulate the transport and dispersion of a nonreactive, nondepositing tracer plu...

  9. Mental Stress-Induced-Myocardial Ischemia in Young Patients With Recent Myocardial Infarction: Sex Differences and Mechanisms.

    PubMed

    Vaccarino, Viola; Sullivan, Samaah; Hammadah, Muhammad; Wilmot, Kobina; Al Mheid, Ibhar; Ramadan, Ronnie; Elon, Lisa; Pimple, Pratik M; Garcia, Ernest V; Nye, Jonathon; Shah, Amit J; Alkhoder, Ayman; Levantsevych, Oleksiy; Gay, Hawkins; Obideen, Malik; Huang, Minxuan; Lewis, Tené T; Bremner, J Douglas; Quyyumi, Arshed A; Raggi, Paolo

    2018-02-20

    Mental stress-induced myocardial ischemia (MSIMI) is frequent in patients with coronary artery disease and is associated with worse prognosis. Young women with a previous myocardial infarction (MI), a group with unexplained higher mortality than men of comparable age, have shown elevated rates of MSIMI, but the mechanisms are unknown. We studied 306 patients (150 women and 156 men) ≤61 years of age who were hospitalized for MI in the previous 8 months and 112 community controls (58 women and 54 men) frequency matched for sex and age to the patients with MI. Endothelium-dependent flow-mediated dilation and microvascular reactivity (reactive hyperemia index) were measured at rest and 30 minutes after mental stress. The digital vasomotor response to mental stress was assessed using peripheral arterial tonometry. Patients received 99m Tc-sestamibi myocardial perfusion imaging at rest, with mental (speech task) and conventional (exercise/pharmacological) stress. The mean age of the sample was 50 years (range, 22-61). In the MI group but not among controls, women had a more adverse socioeconomic and psychosocial profile than men. There were no sex differences in cardiovascular risk factors, and among patients with MI, clinical severity tended to be lower in women. Women in both groups showed a higher peripheral arterial tonometry ratio during mental stress but a lower reactive hyperemia index after mental stress, indicating enhanced microvascular dysfunction after stress. There were no sex differences in flow-mediated dilation changes with mental stress. The rate of MSIMI was twice as high in women as in men (22% versus 11%, P =0.009), and ischemia with conventional stress was similarly elevated (31% versus 16%, P =0.002). Psychosocial and clinical risk factors did not explain sex differences in inducible ischemia. Although vascular responses to mental stress (peripheral arterial tonometry ratio and reactive hyperemia index) also did not explain sex differences in MSIMI, they were predictive of MSIMI in women only. Young women after MI have a 2-fold likelihood of developing MSIMI compared with men and a similar increase in conventional stress ischemia. Microvascular dysfunction and peripheral vasoconstriction with mental stress are implicated in MSIMI among women but not among men, perhaps reflecting women's proclivity toward ischemia because of microcirculatory abnormalities. © 2018 American Heart Association, Inc.

  10. Validity of Predicting Left Ventricular End Systolic Pressure Changes Following An Acute Bout of Exercise

    PubMed Central

    Kappus, Rebecca M.; Ranadive, Sushant M.; Yan, Huimin; Lane, Abbi D.; Cook, Marc D.; Hall, Grenita; Harvey, I. Shevon; Wilund, Kenneth R.; Woods, Jeffrey A.; Fernhall, Bo

    2012-01-01

    Objective Left ventricular end systolic pressure (LV ESP) is important in assessing left ventricular performance. LV ESP is usually derived from prediction equations. It is unknown whether these equations are accurate at rest or following exercise in a young, healthy population. Design We compared measured LV ESP versus LV ESP values from the prediction equations at rest, 15 minutes and 30 minutes following peak aerobic exercise in 60 participants. Methods LV ESP was obtained by applanation tonometry at rest, 15 minutes post and 30 minutes post peak cycle exercise. Results Measured LV ESP was significantly lower (p<0.05) at all time points in comparison to the two calculated values. Measured LV ESP decreased significantly from rest at both the post15 and post30 time points (p<0.05) and changed differently in comparison to the calculated values (significant interaction; p<0.05). The two LV ESP equations were also significantly different from each other (p<0.05) and changed differently over time (significant interaction; p<0.05). Conclusions These data indicate that the two prediction equations commonly used did not accurately predict either resting or post exercise LV ESP in a young, healthy population. Thus, LV ESP needs to be individually determined in young healthy participants. Non-invasive measurement through applanation tonometry appears to allow for a more accurate determination of LV ESP. PMID:22721862

  11. Validity of predicting left ventricular end systolic pressure changes following an acute bout of exercise.

    PubMed

    Kappus, Rebecca M; Ranadive, Sushant M; Yan, Huimin; Lane, Abbi D; Cook, Marc D; Hall, Grenita; Harvey, I Shevon; Wilund, Kenneth R; Woods, Jeffrey A; Fernhall, Bo

    2013-01-01

    Left ventricular end systolic pressure (LV ESP) is important in assessing left ventricular performance and is usually derived from prediction equations. It is unknown whether these equations are accurate at rest or following exercise in a young, healthy population. Measured LV ESP vs. LV ESP values from the prediction equations were compared at rest, 15 min and 30 min following peak aerobic exercise in 60 participants. LV ESP was obtained by applanation tonometry at rest, 15 min post and 30 min post peak cycle exercise. Measured LV ESP was significantly lower (p<0.05) at all time points in comparison to the two calculated values. Measured LV ESP decreased significantly from rest at both the post15 and post30 time points (p<0.05) and changed differently in comparison to the calculated values (significant interaction; p<0.05). The two LV ESP equations were also significantly different from each other (p<0.05) and changed differently over time (significant interaction; p<0.05). The two commonly used prediction equations did not accurately predict either resting or post exercise LV ESP in a young, healthy population. Thus, LV ESP needs to be individually determined in young, healthy participants. Non-invasive measurement through applanation tonometry appears to allow for a more accurate determination of LV ESP. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  12. [Gastric mucosa tonometry in routine monitoring in the surgical intensive care unit].

    PubMed

    Pestel, G; Uhlig, T; Götschl, A; Schmucker, P; Rothhammer, A

    1998-06-01

    Monitoring tissue oxygenation in the splanchnic region could be helpful for critically ill patients. In this study the postoperative course of gastric mucosal CO2 (prCO2) in 40 patients is shown. Following approval of the ethics committee, 24 patients schedulded for surgery with an expected large fluid turnover and 16 multiple injured patients were monitored with a gas tonometry device in addition to standard monitoring (ECG, pulse oximetry, capnometry, CVP, arterial pressure). Normoventilated patients with prCO2 > 50 for more than 30 minutes were treated with fluid therapy, followed by catecholamine therapy, followed by transfusion (fig. 1). All patients were admitted to the SICU post-operatively. The variation of prCO2-values was greater in multiple injured patients. Their prCO2-values began in a lower range compared to patients with scheduled operation, became higher at the end of the first SICU-day and remained higher thereafter. They had a higher fluid turnover and needed more catecholamines. Multiple injured patients with an arterio-intestinal CO2-Difference (CO2-Gap) > 10 had a higher ISS-Score, were longer mechanically ventilated, had a longer SICU-stay and a higher incidence of complications in comparison to patients with aCO2-Gap < 10. Perhaps a CO2-Gap > 10 could be predictive for a more severe course in intensive care patients.

  13. Reliability of peripheral arterial tonometry in patients with heart failure, diabetic nephropathy and arterial hypertension.

    PubMed

    Weisrock, Fabian; Fritschka, Max; Beckmann, Sebastian; Litmeier, Simon; Wagner, Josephine; Tahirovic, Elvis; Radenovic, Sara; Zelenak, Christine; Hashemi, Djawid; Busjahn, Andreas; Krahn, Thomas; Pieske, Burkert; Dinh, Wilfried; Düngen, Hans-Dirk

    2017-08-01

    Endothelial dysfunction plays a major role in cardiovascular diseases and pulse amplitude tonometry (PAT) offers a non-invasive way to assess endothelial dysfunction. However, data about the reliability of PAT in cardiovascular patient populations are scarce. Thus, we evaluated the test-retest reliability of PAT using the natural logarithmic transformed reactive hyperaemia index (LnRHI). Our cohort consisted of 91 patients (mean age: 65±9.7 years, 32% female), who were divided into four groups: those with heart failure with preserved ejection fraction (HFpEF) ( n=25), heart failure with reduced ejection fraction (HFrEF) ( n=22), diabetic nephropathy ( n=21), and arterial hypertension ( n=23). All subjects underwent two separate PAT measurements at a median interval of 7 days (range 4-14 days). LnRHI derived by PAT showed good reliability in subjects with diabetic nephropathy (intra-class correlation (ICC) = 0.863) and satisfactory reliability in patients with both HFpEF (ICC = 0.557) and HFrEF (ICC = 0.576). However, in subjects with arterial hypertension, reliability was poor (ICC = 0.125). We demonstrated that PAT is a reliable technique to assess endothelial dysfunction in adults with diabetic nephropathy, HFpEF or HFrEF. However, in subjects with arterial hypertension, we did not find sufficient reliability, which can possibly be attributed to variations in heart rate and the respective time of the assessments. Clinical Trial Registration Identifier: NCT02299960.

  14. Correlations between different tonometries and ocular biometric parameters in patients with primary congenital glaucoma.

    PubMed

    Mendes, Marcio Henrique; Betinjane, Alberto Jorge; Quiroga, Veronica Andrea

    2013-01-01

    To identify the correlation between the difference of intraocular pressure measurements (IOP) obtained using the Goldmann applanation tonometer (GAT) and three others tonometers (Handheld applanation tonometer - HAT, Dynamic contour tonometer - DCT and Tono-Pen®) with biometric characteristics (corneal diameter, pachymetry, keratometry and axial length) in patients with congenital glaucoma. A cross-sectional study was performed on 46 eyes from 46 patients with congenital glaucoma. IOP measurements were obtained in all patients using GAT, HAT, DCT and Tono-Pen®. Keratometry, pachymetry, biometry and corneal diameter measurements were performed after the IOP measurement. The order of the tonometries was randomized. The correlations between the differences of IOP values of GAT and the other tonometers (Delta-IOP), and the different biometric parameters were studied. Tono-Pen® Delta IOP revealed moderate positive correlation to keratometry (r=0.41, p=0.004). The other Delta-IOPs showed no correlation with any of the biometric characteristics evaluated. IOP differences between GAT (gold standard) and GAT, HAT, DCT or Tono-Pen tonometers seem not to correlate with majority of ocular biometric characteristics. The only exception was the keratometry, which correlated in a positive and moderate way with Tono-Pen® Delta-IOP. This result suggests that the differences of IOP values of Tono-Pen® and GAT increase with the steepness of the cornea.

  15. Noninvasive Evaluation of Varying Pulse Pressures in vivo Using Brachial Sphymomanometry, Applanation Tonometry, and Pulse Wave Ultrasound Manometry.

    PubMed

    Li, Ronny X; Ip, Ada; Sanz-Miralles, Elena; Konofagou, Elisa E

    2017-06-01

    The routine assessment and monitoring of hypertension may benefit from the evaluation of arterial pulse pressure (PP) at more central locations (e.g. the aorta) rather solely at the brachial artery. Pulse Wave Ultrasound Manometry (PWUM) was previously developed by our group to provide direct, noninvasive aortic PP measurements using ultrasound elasticity imaging. Using PWUM, radial applanation tonometry, and brachial sphygmomanometry, this study investigated the feasibility of noninvasively obtaining direct PP measurements at multiple arterial locations in normotensive, pre-hypertensive, and hypertensive human subjects. Two-way ANOVA indicated a significantly higher aortic PP in the hypertensive subjects, while radial and brachial PP were not significantly different among the subject groups. No strong correlation (r 2 < 0.45) was observed between aortic and radial/brachial PP in normal and pre-hypertensive subjects, suggesting that increases in PP throughout the arterial tree may not be uniform in relatively compliant arteries. However, there was a relatively strong positive correlation between aortic PP and both radial and brachial PP in hypertensive subjects (r 2 = 0.68 and 0.87, respectively). PWUM provides a low-cost, non-invasive, and direct means of measuring the pulse pressure in large central arteries such as the aorta. When used in conjunction with peripheral measurement devices, PWUM allows for the routine screening of hypertension and monitoring of BP-lowering drugs based on the PP from multiple arterial sites.

  16. Quantitative evaluation of an air-monitoring network using atmospheric transport modeling and frequency of detection methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rood, Arthur S.; Sondrup, A. Jeffrey; Ritter, Paul D.

    A methodology to quantify the performance of an air monitoring network in terms of frequency of detection has been developed. The methodology utilizes an atmospheric transport model to predict air concentrations of radionuclides at the samplers for a given release time and duration. Frequency of detection is defined as the fraction of “events” that result in a detection at either a single sampler or network of samplers. An “event” is defined as a release of finite duration that begins on a given day and hour of the year from a facility with the potential to emit airborne radionuclides. Another metricmore » of interest is the network intensity, which is defined as the fraction of samplers in the network that have a positive detection for a given event. The frequency of detection methodology allows for evaluation of short-term releases that include effects of short-term variability in meteorological conditions. The methodology was tested using the U.S. Department of Energy Idaho National Laboratory (INL) Site ambient air monitoring network consisting of 37 low-volume air samplers in 31 different locations covering a 17,630 km 2 region. Releases from six major INL facilities distributed over an area of 1,435 km 2 were modeled and included three stack sources and eight ground-level sources. A Lagrangian Puff air dispersion model (CALPUFF) was used to model atmospheric transport. The model was validated using historical 125Sb releases and measurements. Relevant one-week release quantities from each emission source were calculated based on a dose of 1.9 × 10 –4 mSv at a public receptor (0.01 mSv assuming release persists over a year). Important radionuclides considered include 241Am, 137Cs, 238Pu, 239Pu, 90Sr, and tritium. Results show the detection frequency is over 97.5% for the entire network considering all sources and radionuclides. Network intensities ranged from 3.75% to 62.7%. Evaluation of individual samplers indicated some samplers were poorly situated and add little to the overall effectiveness of the network. As a result, using the frequency of detection methods, optimum sampler placements were simulated that could substantially improve the performance and efficiency of the network.« less

  17. Quantitative evaluation of an air-monitoring network using atmospheric transport modeling and frequency of detection methods

    DOE PAGES

    Rood, Arthur S.; Sondrup, A. Jeffrey; Ritter, Paul D.

    2016-04-01

    A methodology to quantify the performance of an air monitoring network in terms of frequency of detection has been developed. The methodology utilizes an atmospheric transport model to predict air concentrations of radionuclides at the samplers for a given release time and duration. Frequency of detection is defined as the fraction of “events” that result in a detection at either a single sampler or network of samplers. An “event” is defined as a release of finite duration that begins on a given day and hour of the year from a facility with the potential to emit airborne radionuclides. Another metricmore » of interest is the network intensity, which is defined as the fraction of samplers in the network that have a positive detection for a given event. The frequency of detection methodology allows for evaluation of short-term releases that include effects of short-term variability in meteorological conditions. The methodology was tested using the U.S. Department of Energy Idaho National Laboratory (INL) Site ambient air monitoring network consisting of 37 low-volume air samplers in 31 different locations covering a 17,630 km 2 region. Releases from six major INL facilities distributed over an area of 1,435 km 2 were modeled and included three stack sources and eight ground-level sources. A Lagrangian Puff air dispersion model (CALPUFF) was used to model atmospheric transport. The model was validated using historical 125Sb releases and measurements. Relevant one-week release quantities from each emission source were calculated based on a dose of 1.9 × 10 –4 mSv at a public receptor (0.01 mSv assuming release persists over a year). Important radionuclides considered include 241Am, 137Cs, 238Pu, 239Pu, 90Sr, and tritium. Results show the detection frequency is over 97.5% for the entire network considering all sources and radionuclides. Network intensities ranged from 3.75% to 62.7%. Evaluation of individual samplers indicated some samplers were poorly situated and add little to the overall effectiveness of the network. As a result, using the frequency of detection methods, optimum sampler placements were simulated that could substantially improve the performance and efficiency of the network.« less

  18. Academic Value of Non-Academics: The Case for Keeping Extracurriculars

    ERIC Educational Resources Information Center

    Kronholz, June

    2012-01-01

    With school districts struggling to keep their noses above choppy budget waters and voters howling about taxes, should schools be funding Ping-Pong and trading-card clubs? Swim teams, moot court, powder puff football? Latino unions, gay-straight alliances, the Future Business Leaders of America, the French Honors Society, the jazz band, the…

  19. Tonopah Test Range Flight Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    From a distance, the drop of a mock nuclear weapon — containing only non-nuclear components — was a mere puff of dust rising from a dry lake bed at Nevada’s Tonopah Test Range. However, it marked the start of a new series of test flights vital to the nation’s B61-12 weapon refurbishment program.

  20. A study of mass loss from the mid-ultraviolet spectrum of Alpha Cygni /A2 Ia/, Beta Orionis /B8 Ia/, and Eta Leonis /A0 Ib/

    NASA Technical Reports Server (NTRS)

    Lamers, H. J. G. L. M.; Stalio, R.; Kondo, Y.

    1978-01-01

    Results are presented for a study of mass loss from A and late-B supergiants based on high-resolution mid-UV spectra obtained with the echelle spectrograph of the Balloon-borne Ultraviolet Stellar Spectrometer. Spectra of Alpha Cyg, Beta Ori, Eta Leo, and Alpha Lyr are compared in selected wavelength regions; particular attention is given to previous observations of each star, the Mg II and Fe II resonance lines, lines due to other ions, and evidence for mass ejection. The results indicate that mass loss from late-B and A supergiants is variable, that a considerable fraction of envelope material is ejected in 'puffs', and that the puffs may be due to photospheric instabilities. A mass-loss rate of about 1 hundred-millionth of a solar mass per year is derived for Alpha Cyg and shown to be two orders of magnitude smaller than the value determined from the observed IR excess. This discrepancy is attributed to excess ionization in the envelope.

  1. Detection of nicotine content impact in tobacco manufacturing using computational intelligence.

    PubMed

    Begic Fazlic, Lejla; Avdagic, Zikrija

    2011-01-01

    A study is presented for the detection of nicotine impact in different cigarette type, using recorded data and Computational Intelligence techniques. Recorded puffs are processed using Continuous Wavelet Transform and used to extract time-frequency features for normal and abnormal puffs conditions. The wavelet energy distributions are used as inputs to classifiers based on Adaptive Neuro-Fuzzy Inference Systems (ANFIS) and Genetic Algorithms (GAs). The number and the parameters of Membership Functions are used in ANFIS along with the features from wavelet energy distributionare selected using GAs, maximising the diagnosis success. GA with ANFIS (GANFIS) are trained with a subset of data with known nicotine conditions. The trained GANFIS are tested using the other set of data (testing data). A classical method by High-Performance Liquid Chromatography is also introduced to solve this problem, respectively. The results as well as the performances of these two approaches are compared. A combination of these two algorithms is also suggested to improve the efficiency of this solution procedure. Computational results show that this combined algorithm is promising.

  2. Asymmetrical Macromolecular Complex Formation of Lysophosphatidic Acid Receptor 2 (LPA2) Mediates Gradient Sensing in Fibroblasts*

    PubMed Central

    Ren, Aixia; Moon, Changsuk; Zhang, Weiqiang; Sinha, Chandrima; Yarlagadda, Sunitha; Arora, Kavisha; Wang, Xusheng; Yue, Junming; Parthasarathi, Kaushik; Heil-Chapdelaine, Rick; Tigyi, Gabor; Naren, Anjaparavanda P.

    2014-01-01

    Chemotactic migration of fibroblasts toward growth factors relies on their capacity to sense minute extracellular gradients and respond to spatially confined receptor-mediated signals. Currently, mechanisms underlying the gradient sensing of fibroblasts remain poorly understood. Using single-particle tracking methodology, we determined that a lysophosphatidic acid (LPA) gradient induces a spatiotemporally restricted decrease in the mobility of LPA receptor 2 (LPA2) on chemotactic fibroblasts. The onset of decreased LPA2 mobility correlates to the spatial recruitment and coupling to LPA2-interacting proteins that anchor the complex to the cytoskeleton. These localized PDZ motif-mediated macromolecular complexes of LPA2 trigger a Ca2+ puff gradient that governs gradient sensing and directional migration in response to LPA. Disruption of the PDZ motif-mediated assembly of the macromolecular complex of LPA2 disorganizes the gradient of Ca2+ puffs, disrupts gradient sensing, and reduces the directional migration of fibroblasts toward LPA. Our findings illustrate that the asymmetric macromolecular complex formation of chemoattractant receptors mediates gradient sensing and provides a new mechanistic basis for models to describe gradient sensing of fibroblasts. PMID:25542932

  3. Effect of resistivity profile on current decay time of initial phase of current quench in neon-gas-puff inducing disruptions of JT-60U

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawakami, S.; Ohno, N.; Shibata, Y.

    2013-11-15

    According to an early work [Y. Shibata et al., Nucl. Fusion 50, 025015 (2010)] on the behavior of the plasma current decay in the JT-60U disruptive discharges caused by the radiative collapse with a massive neon-gas-puff, the increase of the internal inductance mainly determined the current decay time of plasma current during the initial phase of current quench. To investigate what determines the increase of the internal inductance, we focus attention on the relationship between the electron temperature (or the resistivity) profile and the time evolution of the current density profile and carry out numerical calculations. As a result, wemore » find the reason of the increase of the internal inductance: The current density profile at the start of the current quench is broader than an expected current density profile in the steady state, which is determined by the temperature (or resistivity) profile. The current density profile evolves into peaked one and the internal inductance is increasing.« less

  4. Contextual startle responses moderate the relation between behavioral inhibition and anxiety in middle childhood.

    PubMed

    Barker, Tyson V; Reeb-Sutherland, Bethany; Degnan, Kathryn A; Walker, Olga L; Chronis-Tuscano, Andrea; Henderson, Heather A; Pine, Daniel S; Fox, Nathan A

    2015-11-01

    Behavioral inhibition (BI), a temperament characterized in early childhood by wariness and avoidance of novelty, is a risk factor for anxiety disorders. An enhanced startle response has been observed in adolescents characterized with BI in childhood, particularly when they also manifest concurrent symptoms of anxiety. However, no prior study has examined relations among BI, startle responsivity, and anxiety in a prospective manner. Data for the present study were from a longitudinal study of infant temperament. Maternal reports and observations of BI were assessed at ages 2 and 3. At age 7, participants completed a startle procedure, while electromyography was collected, where participants viewed different colors on a screen that were associated with either the delivery of an aversive stimulus (i.e., puff of air to the larynx; threat cue) or the absence of the aversive stimulus (i.e., safety cue). Parental reports of child anxiety were collected when children were 7 and 9 years of age. Results revealed that startle responses at age 7 moderated the relation between early BI and 9-year anxiety. These findings provide insight into one potential mechanism that may place behaviorally inhibited children at risk for anxiety. © 2015 Society for Psychophysiological Research.

  5. Young adult waterpipe smokers: Smoking behaviors and associated subjective and physiological effects.

    PubMed

    Shishani, Kawkab; Howell, Donelle; McPherson, Sterling; Roll, John

    2014-06-01

    The purpose of this pilot study was to investigate smoking behaviors and subjective and physiological effects of nicotine on young adult occasional waterpipe smokers. This study utilized a repeated-measures design that included one repeated factor for condition (nicotine and non-nicotine). For each participant, the sequencing of the repeated factor was assigned using random allocation. The two nicotine conditions were nicotine (0.75 g) and non-nicotine (0 g placebo) tobacco. Over the course of two weeks, twenty-two participants completed subjective (Acute Subjective Effects of Nicotine) and physiological (blood pressure, heart rate, and CO level) measures. Additional measures (QSU and MNWS-R) were used to assess for withdrawal symptoms. The participants (n=22) were young adults (23 ± 3.1years); 71% smoked waterpipe once a month in the past year and 29% smoked waterpipe 1-2 times per week. In addition, 60% reported sharing their waterpipe with friends while smoking. None of the participants reported using any other forms of tobacco products. Under the nicotine condition, participants tended to smoke longer (i.e. smoking duration, p=0.004), take more puffs (p=0.03), take shorter puffs (p=0.03), and inhale less volume with each puff (p=0.02). The repeated measures analysis of the factor headrush revealed an effect of the nicotine condition (F=9.69, p<0.001, partial η(2)=0.31) and time (F=8.17, p=0.02, partial η(2)=0.30). Heart rate increased significantly across the nicotine condition (F=7.92, p=0.01, partial η(2)=0.31) and over time (F=12.64, p=0.01, partial η(2)=0.41). This study demonstrates how differences between nicotine and non-nicotine waterpipe smoking are associated with changes in smoking behaviors, experiencing a headrush and an increase in heart rate. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Improved confinement in highly powered high performance scenarios on DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrie, Thomas W.; Osborne, Thomas; Fenstermacher, Max E.

    DIII-D has recently demonstrated improved energy confinement by injecting neutral deuterium gas into high performance near-double null divertor (DND) plasmas during high power operation. Representative parameters for these plasmas are: q 95 = 6, P IN up to 15 MW, H 98 = 1.4–1.8, and β N = 2.5–4.0. The ion B xmore » $$\\triangledown$$B direction is away from the primary X-point. While plasma conditions at lower to moderate power input (e.g., 11 MW) are shown to be favorable to successful puff-and-pump radiating divertor applications, particularly when using argon seeds, plasma behavior at higher powers (e.g., ≥14 MW) may make successful puff-and-pump operation more problematic. In contrast to lower powered high performance plasmas, both $$\\tau$$ E and β N in the high power cases (≥14 MW) increased and ELM frequency decreased, as density was raised by deuterium gas injection. Improved performance in the higher power plasmas was tied to higher pedestal pressure, which according to peeling-ballooning mode stability analysis using the ELITE code could increase with density along the kink/peeling stability threshold, while the pedestal pressure gradient in the lower power discharges were limited by the ballooning threshold. This resulted in improved fueling efficiency and ≈10% higher $$\\tau$$ E and β N than is normally observed in comparable high performance plasmas on DIII-D. Applying the puff-and-pump radiating divertor approach at moderate versus high power input is shown to result in a much different evolution in core and pedestal plasma behavior. In conclusion, we find that injecting deuterium gas into these highly powered DND plasmas may open up a new avenue for achieving elevated plasma performance, including better fueling, but the resulting higher density may also complicate application of a radiating divertor approach to heat flux reduction in present-day tokamaks, if scenarios involving second-harmonic electron cyclotron heating are used.« less

  7. Fugitive Dust Emission Factors for Puff and Mobile Military Sources Measured by Micro-pulse Lidar - A Summary of Results

    NASA Astrophysics Data System (ADS)

    Yuen, W.; Du, K.; Rood, M. J.; Kemme, M. R.; Kim, B.; Hashmonay, R. A.

    2010-12-01

    A summary of the development of a novel optical remote sensing (ORS) method that determined fugitive dust emission factors for unique military activities is described for puff and mobile sources. Four field campaigns characterized artillery back blasts as puff sources (M549A1 and M107), and movement of military vehicles (M1A1, M113, Bradley Fighting Vehicle (BFV), M88, M270, M577, and HEMTT) and an airborne helicopter (Bell 210) as mobile sources. The ORS method includes a Micro-Pulse Lidar (MPL) and a reflective target that determines one-dimensional (1-D) light extinction coefficient profiles. The MPL was mounted on a positioner that allows the MPL to automatically scan vertically, which allowed 1-D extinction coefficient profiles to be measured at select angles from horizontal. Two-dimensional (2-D) light extinction coefficient profiles were then determined by interpolating the 1-D extinction profiles measured at select angles. Dust property, in the form of the mass extinction efficiency (MEE), was measured using Open Path- Fourier Transform Infrared Spectrometry (OP-FTIR) and Open Path- Laser Transmissometry (OP-LT) in the first three field campaigns and an OP-LT and DustTrak™ in the fourth field campaign. MEE was used to convert the 2-D light extinction coefficient profiles to 2-D dust mass concentration profiles. Emission factors were determined by integrating the 2-D mass concentration profiles with measured wind vectors. Results from these field campaigns show that: 1) artillery with stronger recoiling forces generates more fugitive dust; 2) the dust emission factors for tracked vehicles are correlated with vehicle momentum; 3) emission factor decreases with increasing speed for airborne helicopters; and 4) wheeled vehicles (HEMTT) generate more fugitive dust than tracked vehicles (M88, M270, M577).

  8. Simple Determination of Gaseous and Particulate Compounds Generated from Heated Tobacco Products.

    PubMed

    Uchiyama, Shigehisa; Noguchi, Mayumi; Takagi, Nao; Hayashida, Hideki; Inaba, Yohei; Ogura, Hironao; Kunugita, Naoki

    2018-06-19

    As a new form of cigarettes, heated tobacco products (HTPs) have been rapidly distributed worldwide. In this study, an improved method for analyzing gaseous and particulate compounds generated from HTPs is described. Smoke is collected using a GF-CX572 sorbent cartridge with 300 mg of carbon molecular sieves, that is, Carboxen 572 (CX572), and a 9 mm glass-fiber filter (GF). After collection, the CX572 particles from the cartridge are transferred along with the GF and deposited into a vial containing two phases of carbon disulfide and methanol. The CX572 particles settle into the lower carbon disulfide phase, while nonpolar compounds are desorbed. After the sample is allowed to stand, the solution is slowly stirred. The two-phase mixture of carbon disulfide and methanol is combined into a homogeneous solution. Polar compounds are then desorbed, while the desorbed nonpolar compounds remain in solution. For the analysis of carbonyl compounds, an enriched 2,4-dinitrophenylhydrazine solution is added to a portion of the combined solution for derivatization and subsequent high-performance liquid chromatography analysis. For the analysis of volatile organic compounds and water, a portion of the combined solution is analyzed by gas chromatography-mass spectrometry or equipped with a thermal conductivity detector. By applying the proposed GF-CX572 one-cartridge method to the analysis of the mainstream smoke generated from HTPs and traditional cigarettes, several chemical compounds are detected, and the chemical composition of smoke is revealed. The GF-CX572 one-cartridge method can analyze gaseous and particulate chemical compounds from the HTP smoke by utilizing not only the entire puff volume but also one puff volume because the GF-CX-572 cartridge can be replaced with a new cartridge within 3 s. An overview of the chemicals generated from HTPs is obtained in detail by one-puff volume sampling. In addition, the generated chemical compounds strongly depend on the temperature of tobacco leaves in HTPs.

  9. Reduced Exposure to Harmful and Potentially Harmful Smoke Constituents With the Tobacco Heating System 2.1

    PubMed Central

    Baker, Gizelle; Magnette, John; Picavet, Patrick; Weitkunat, Rolf

    2017-01-01

    Introduction: Heating rather than burning tobacco reduces levels of harmful and potentially harmful constituents, and consumer products using this approach aim to reduce exposure to tobacco toxicants. The Tobacco Heating System (THS) version 2.1 has been enhanced from earlier prototypes with an improved heat control and sensorial experience and thereby user acceptance. Exposure measurements are required to determine whether it may be possible to reduce the individual health risk compared to smoking combustible cigarettes (CCs). Methods: This controlled clinical study randomly assigned 40 smokers to either a group continuing to use of their own CC brand (n = 20) or a group switching to THS 2.1 (n = 20) for 5 days. Biomarkers of exposure were measured at baseline and on day 1 through day 5. Product consumption, Human Puffing Topography, the occurrence of adverse events, and an assessment of subjective effects, such as smoking satisfaction and enjoyment of respiratory tract sensations, were also determined. Results: The group of smokers who switched to THS 2.1 adapted their puffing behavior initially through longer puff duration and more puffs. During the duration of the study, total puff volume returned to baseline levels and the mean daily product consumption increased but with similar nicotine exposure compared to baseline CC use. Biomarkers of exposure to tobacco smoke toxicants which inform product risk assessment were significantly reduced with THS use compared to the CC group. THS 2.1 users experienced less reinforcing effects with THS 2.1 than with their own cigarette brand. Conclusions: THS 2.1 is a promising alternative to smoking CCs. Notwithstanding possible use adaption through consumption or puffing behavior, the exposure to harmful smoke constituents was markedly reduced with the new heated tobacco platform. Implications: Exposure markers to harmful and potentially harmful smoke constituents were lowered with the THS 2.1. Heating tobacco instead of burning can offer a potentially lower risk of delivering nicotine compared to CCs. PMID:27613951

  10. Effect of retinal impulse blockage on cytochrome oxidase-poor interpuffs in the macaque striate cortex: quantitative EM analysis of neurons.

    PubMed

    Wong-Riley, M T; Trusk, T C; Kaboord, W; Huang, Z

    1994-09-01

    One of the hallmarks of the primate striate cortex is the presence of cytochrome oxidase-rich puffs in its supragranular layers. Neurons in puffs have been classified as type A, B, and C in ascending order of cytochrome oxidase content, with type C cells being the most vulnerable to retinal impulse blockade. The present study aimed at analysing cytochrome oxidase-poor interpuffs with reference to their metabolic cell types and the effect of intraretinal tetrodotoxin treatment. The same three metabolic types were found in interpuffs, except that type B and C neurons were smaller and less cytochrome oxidase-reactive in interpuffs than in puffs. Type A neurons had small perikarya, low levels of cytochrome oxidase, and received exclusively symmetric axosomatic synapses. The largest neurons were pyramidal, type B cells with moderate cytochrome oxidase activity and were also contacted exclusively by symmetric axosomatic synapses. Type C cells medium-sized with a rich supply of large, darkly reactive mitochondria and possessed all the characteristics of GABAergic neurons. They were the only cell type that received both symmetric and asymmetric axosomatic synapses. Two weeks of monocular tetrodotoxin blockade in adult monkeys caused all three major cell types in deprived interpuffs to suffer a significant downward shift in the size and cytochrome oxidase reactivity of their mitochondria, but the effects were more severe in type B and C neurons. In nondeprived interpuffs, all three cell types gained both in size and absolute number of mitochondria, and type A cells also had an elevated level of cytochrome oxidase, indicating that they might be functioning at a competitive advantage over cells in deprived columns. However, type B and C neurons showed a net loss of darkly reactive mitochondria, indicating that these cells became less active. Thus, mature interpuff neurons remained vulnerable to retinal impulse blockade and the metabolic capacity of these cells remains tightly regulated by neuronal activity.

  11. Are metals emitted from electronic cigarettes a reason for health concern? A risk-assessment analysis of currently available literature.

    PubMed

    Farsalinos, Konstantinos E; Voudris, Vassilis; Poulas, Konstantinos

    2015-05-15

    Studies have found that metals are emitted to the electronic cigarette (EC) aerosol. However, the potential health impact of exposure to such metals has not been adequately defined. The purpose of this study was to perform a risk assessment analysis, evaluating the exposure of electronic cigarette (EC) users to metal emissions based on findings from the published literature. Two studies were found in the literature, measuring metals emitted to the aerosol from 13 EC products. We estimated that users take on average 600 EC puffs per day, but we evaluated the daily exposure from 1200 puffs. Estimates of exposure were compared with the chronic Permissible Daily Exposure (PDE) from inhalational medications defined by the U.S. Pharmacopeia (cadmium, chromium, copper, lead and nickel), the Minimal Risk Level (MRL) defined by the Agency for Toxic Substances and Disease Registry (manganese) and the Recommended Exposure Limit (REL) defined by the National Institute of Occupational Safety and Health (aluminum, barium, iron, tin, titanium, zinc and zirconium). The average daily exposure from 13 EC products was 2.6 to 387 times lower than the safety cut-off point of PDEs, 325 times lower than the safety limit of MRL and 665 to 77,514 times lower than the safety cut-off point of RELs. Only one of the 13 products was found to result in exposure 10% higher than PDE for one metal (cadmium) at the extreme daily use of 1200 puffs. Significant differences in emissions between products were observed. Based on currently available data, overall exposure to metals from EC use is not expected to be of significant health concern for smokers switching to EC use, but is an unnecessary source of exposure for never-smokers. Metal analysis should be expanded to more products and exposure can be further reduced through improvements in product quality and appropriate choice of materials.

  12. Cross-sectional and prospective relation of cannabis potency, dosing and smoking behaviour with cannabis dependence: an ecological study.

    PubMed

    van der Pol, Peggy; Liebregts, Nienke; Brunt, Tibor; van Amsterdam, Jan; de Graaf, Ron; Korf, Dirk J; van den Brink, Wim; van Laar, Margriet

    2014-07-01

    Increased delta-9-tetrahydrocannabinol (THC) concentrations in cannabis may lead to higher THC exposure, cannabis dependence and treatment need, but users may also adapt the actual intake of THC through reduced inhalation of THC containing smoke (titration). We investigated whether consumers of stronger cannabis use less cannabis per joint or inhale less smoke than those using less potent cannabis and whether these factors predict cannabis dependence severity. Heavy cannabis users (n = 98) brought their own cannabis, rolled a joint and smoked it ad libitum in a naturalistic setting. We analysed the content of the joint, its association with smoking behaviour and the cross-sectional and prospective (1.5-year follow-up) relations between smoking behaviour and cannabis dependence severity (total number of DSM-IV dependence symptoms). THC concentration in cannabis (range 1.10-24.70%) was correlated positively with cannabis dose per joint (b = 0.008, P = 0.01), but the resulting THC concentration per joint (range 0.24-15.72%) was associated negatively with inhalation volume (b = -0.05, P = 0.03). Smoking behaviour measures (number of puffs, inhaled volume, reduction of puff volume and puff duration while smoking) predicted follow-up dependence severity, independently of baseline dependence severity and monthly THC dose (number of joints × cannabis dose × cannabis THC concentration). Monthly THC dose only predicted follow-up dependence severity when unadjusted for baseline severity. Cannabis users titrate their delta-9-tetrahydrocannabinol intake by inhaling lower volumes of smoke when smoking strong joints, but this does not fully compensate for the higher cannabis doses per joint when using strong cannabis. Thus, users of more potent cannabis are generally exposed to more delta-9-tetrahydrocannabinol. Smoking behaviour appears to be a stronger predictor for cannabis dependence severity than monthly delta-9-tetrahydrocannabinol dose. © 2014 Society for the Study of Addiction.

  13. Improved confinement in highly powered high performance scenarios on DIII-D

    DOE PAGES

    Petrie, Thomas W.; Osborne, Thomas; Fenstermacher, Max E.; ...

    2017-06-09

    DIII-D has recently demonstrated improved energy confinement by injecting neutral deuterium gas into high performance near-double null divertor (DND) plasmas during high power operation. Representative parameters for these plasmas are: q 95 = 6, P IN up to 15 MW, H 98 = 1.4–1.8, and β N = 2.5–4.0. The ion B xmore » $$\\triangledown$$B direction is away from the primary X-point. While plasma conditions at lower to moderate power input (e.g., 11 MW) are shown to be favorable to successful puff-and-pump radiating divertor applications, particularly when using argon seeds, plasma behavior at higher powers (e.g., ≥14 MW) may make successful puff-and-pump operation more problematic. In contrast to lower powered high performance plasmas, both $$\\tau$$ E and β N in the high power cases (≥14 MW) increased and ELM frequency decreased, as density was raised by deuterium gas injection. Improved performance in the higher power plasmas was tied to higher pedestal pressure, which according to peeling-ballooning mode stability analysis using the ELITE code could increase with density along the kink/peeling stability threshold, while the pedestal pressure gradient in the lower power discharges were limited by the ballooning threshold. This resulted in improved fueling efficiency and ≈10% higher $$\\tau$$ E and β N than is normally observed in comparable high performance plasmas on DIII-D. Applying the puff-and-pump radiating divertor approach at moderate versus high power input is shown to result in a much different evolution in core and pedestal plasma behavior. In conclusion, we find that injecting deuterium gas into these highly powered DND plasmas may open up a new avenue for achieving elevated plasma performance, including better fueling, but the resulting higher density may also complicate application of a radiating divertor approach to heat flux reduction in present-day tokamaks, if scenarios involving second-harmonic electron cyclotron heating are used.« less

  14. Bacterial contaminants from frozen puff pastry production process and their growth inhibition by antimicrobial substances from lactic acid bacteria.

    PubMed

    Rumjuankiat, Kittaporn; Keawsompong, Suttipun; Nitisinprasert, Sunee

    2017-05-01

    Seventy-five bacterial contaminants which still persisted to cleaning system from three puff pastry production lines (dough forming, layer and filling forming, and shock freezing) were identified using 16S rDNA as seven genera of Bacillus , Corynebacterium , Dermacoccus , Enterobacter , Klebsiella, Pseudomonas , and Staphylococcus with detection frequencies of 24.00, 2.66, 1.33, 37.33, 1.33, 2.66, and 30.66, respectively. Seventeen species were discovered while only 11 species Bacillus cereus, B. subtilis, B. pumilus, Corynebacterium striatum , Dermacoccus barathri , Enterobacter asburiae, Staphylococcus kloosii, S. haemolyticus, S. hominis, S. warneri , and S. aureus were detected at the end of production. Based on their abundance, the highest abundance of E. asburiae could be used as a biomarker for product quality. While a low abundance of the mesophile pathogen C. striatum , which causes respiratory and nervous infection and appeared only at the shock freezing step was firstly reported for its detection in bakery product. Six antimicrobial substances (AMSs) from lactic acid bacteria, FF1-4, FF1-7, PFUR-242, PFUR-255, PP-174, and nisin A were tested for their inhibition activities against the contaminants. The three most effective were FF1-7, PP-174, and nisin A exhibiting wide inhibition spectra of 88.00%, 85.33%, and 86.66%, respectively. The potential of a disinfectant solution containing 800 AU/ml of PP-174 and nisin A against the most resistant strains of Enterobacter , Staphylococcus , Bacillus and Klebsiella was determined on artificially contaminated conveyor belt coupons at 0, 4, 8, 12, and 16 hr. The survival levels of the test strains were below 1 log CFU/coupon at 0 hr. The results suggested that a combined solution of PP-174 and nisin A may be beneficial as a sanitizer to inhibit bacterial contaminants in the frozen puff pastry industry.

  15. Carbonyl emissions from a novel heated tobacco product (IQOS): comparison with an e-cigarette and a tobacco cigarette.

    PubMed

    Farsalinos, Konstantinos E; Yannovits, Nikoletta; Sarri, Theoni; Voudris, Vassilis; Poulas, Konstantinos; Leischow, Scott

    2018-06-19

    To measure carbonyl emissions from a heated tobacco product (IQOS) in comparison with an e-cigarette (Nautilus Mini) and a commercial tobacco cigarette (Marlboro Red). Regular and menthol variants of the heated tobacco product were tested. A tank-type atomizer was tested with a tobacco-flavoured liquid at 10 W and 14 W. Aerosol and smoke were collected in impingers containing 2,4-dinitrophenylhydrazine. Health Canada Intense and two more intense puffing regimes were used. Analytical laboratory in Greece. Carbonyl levels in the aerosol and smoke. At Health Canada Intense regime, heated tobacco products emitted 5.0-6.4 μg/stick formaldehyde, 144.1-176.7 μg/stick acetaldehyde, 10.4-10.8 μg/stick acrolein, 11.0-12.8 μg/stick propionaldehyde and 1.9-2.0 μg/stick crotonaldehyde. Compared with the tobacco cigarette, levels were on average 91.6% lower for formaldehyde, 84.9% lower for acetaldehyde, 90.6% lower for acrolein, 89.0% lower for propionaldehyde and 95.3% lower for crotonaldehyde. The e-cigarette emitted 0.5-1.0 μg/12 puffs formaldehyde, 0.8-1.5μg/12 puffs acetaldehyde and 0.3-0.4 μg/12 puffs acrolein, but no propionaldehyde and crotonaldehyde. At more intense puffing regimes, formaldehyde was increased in heated tobacco products, but levels were 3 to 4-fold lower compared with the tobacco cigarette. Based on the findings from Health Canada Intense puffing regime, use of 20 heated tobacco sticks would result in 81.7-97.9% reduced carbonyl exposure compared with smoking 20 tobacco cigarettes; the respective reduction in exposure from use of 5 g e-cigarette liquid would be 92.2-99.8%. The IQOS heated tobacco product emits substantially lower levels of carbonyls than a commercial tobacco cigarette (Marlboro Red) but higher levels than a Nautilus Mini e-cigarette. This article is protected by copyright. All rights reserved.

  16. Atmospheres of Two Super-Puffs: Transmission Spectra of Kepler 51b and Kepler 51d

    NASA Astrophysics Data System (ADS)

    Roberts, Jessica; Berta-Thompson, Zachory K.; Desert, Jean-Michel; Deck, Katherine; Fabrycky, Daniel; Fortney, Jonathan J.; Line, Michael R.; Lopez, Eric; Masuda, Kento; Morley, Caroline; Sanchis Ojeda, Roberto; Winn, Joshua N.

    2018-06-01

    The Kepler 51 system hosts three transiting, extremely low-mass, low-density exoplanets. These planets orbit a young G type star at periods of 45, 85 and 130 days, placing them outside of the regime for the inflated hot-Jupiters. Instead, the Kepler 51 planets are part of a rare class of exoplanets: the super-puffs. Models suggest these H/He-rich planets formed outside of the snow-line and migrated inwards, which might imply abundant water in their atmospheres. Because Kepler 51b and 51d have low surface gravities, they also have scale heights 10x larger than a typical hot-Jupiter, making them prime targets for atmospheric investigation. Kepler 51c, while also possessing a large scale height, only grazes its star during transit. We are also presented with a unique opportunity to study two super-puffs in very different temperature regimes around the same star. Therefore, we observed two transits each of both Kepler 51b and 51d with the Hubble Space Telescope’s Wide Field Camera 3 G141 grism spectroscopy. Using these data we created spectroscopic light curves that allow us to compute a transmission spectrum for each planet. We conclude that both planets have a flat transmission spectrum with a precision better than 0.6 scale heights between 1.1 and 1.7 microns. We also analyzed the transit timing variations of each planet by combining re-fitted Kepler mid-transit times with our measured HST times. From these additional timing points, we are able to better constrain the planetary masses and the dynamics of the system. With these updated masses and revisited stellar parameters, we determine precise measurements on the densities of these planets. We will present these results as well as discuss the implications for high altitude aerosols in both Kepler 51b and 51d.

  17. Challenges Encountered Using Ophthalmic Anesthetics in Space Medicine

    NASA Technical Reports Server (NTRS)

    Bayuse, T.; Law, J.; Alexander, D.; Moynihan, S.; LeBlanc, C.; Langford, K.; Magalhaes, L.

    2015-01-01

    On orbit, ophthalmic anesthetics are used for tonometry and off-nominal corneal examinations. Proparacaine has been flown traditionally. However, the manufacturers recently changed its storage requirements from room temperature storage to refrigerated storage to preserve stability and prolong the shelf-life. Since refrigeration on orbit is not readily available and there were stability concerns about flying proparacaine unrefrigerated, tetracaine was selected as an alternative ophthalmic anesthetic in 2013. We will discuss the challenges encountered flying and using these anesthetics on the International Space Station.

  18. Development of a plume-in-grid model for industrial point and volume sources: application to power plant and refinery sources in the Paris region

    NASA Astrophysics Data System (ADS)

    Kim, Y.; Seigneur, C.; Duclaux, O.

    2014-04-01

    Plume-in-grid (PinG) models incorporating a host Eulerian model and a subgrid-scale model (usually a Gaussian plume or puff model) have been used for the simulations of stack emissions (e.g., fossil fuel-fired power plants and cement plants) for gaseous and particulate species such as nitrogen oxides (NOx), sulfur dioxide (SO2), particulate matter (PM) and mercury (Hg). Here, we describe the extension of a PinG model to study the impact of an oil refinery where volatile organic compound (VOC) emissions can be important. The model is based on a reactive PinG model for ozone (O3), which incorporates a three-dimensional (3-D) Eulerian model and a Gaussian puff model. The model is extended to treat PM, with treatments of aerosol chemistry, particle size distribution, and the formation of secondary aerosols, which are consistent in both the 3-D Eulerian host model and the Gaussian puff model. Furthermore, the PinG model is extended to include the treatment of volume sources to simulate fugitive VOC emissions. The new PinG model is evaluated over Greater Paris during July 2009. Model performance is satisfactory for O3, PM2.5 and most PM2.5 components. Two industrial sources, a coal-fired power plant and an oil refinery, are simulated with the PinG model. The characteristics of the sources (stack height and diameter, exhaust temperature and velocity) govern the surface concentrations of primary pollutants (NOx, SO2 and VOC). O3 concentrations are impacted differently near the power plant than near the refinery, because of the presence of VOC emissions at the latter. The formation of sulfate is influenced by both the dispersion of SO2 and the oxidant concentration; however, the former tends to dominate in the simulations presented here. The impact of PinG modeling on the formation of secondary organic aerosol (SOA) is small and results mostly from the effect of different oxidant concentrations on biogenic SOA formation. The investigation of the criteria for injecting plumes into the host model (fixed travel time and/or puff size) shows that a size-based criterion is recommended to treat the formation of secondary aerosols (sulfate, nitrate, and ammonium), in particular, farther downwind of the sources (beyond about 15 km). The impacts of PinG modeling are less significant in a simulation with a coarse grid size (10 km) than with a fine grid size (2 km), because the concentrations of the species emitted from the PinG sources are relatively less important compared to background concentrations when injected into the host model with a coarser grid size.

  19. Development of a plume-in-grid model for industrial point and volume sources: application to power plant and refinery sources in the Paris region

    NASA Astrophysics Data System (ADS)

    Kim, Y.; Seigneur, C.; Duclaux, O.

    2013-11-01

    Plume-in-grid (PinG) models incorporating a host Eulerian model and a subgrid-scale model (usually a Gaussian plume or puff model) have been used for the simulations of stack emissions (e.g., fossil fuel-fired power plants and cement plants) for gaseous and particulate species such as nitrogen oxides (NOx), sulfur dioxide (SO2), particulate matter (PM) and mercury (Hg). Here, we describe the extension of a PinG model to study the impact of an oil refinery where volatile organic compound (VOC) emissions can be important. The model is based on a reactive PinG model for ozone (O3), which incorporates a three-dimensional (3-D) Eulerian model and a Gaussian puff model. The model is extended to treat PM, with treatments of aerosol chemistry, particle size distribution, and the formation of secondary aerosols, which are consistent in both the 3-D Eulerian host model and the Gaussian puff model. Furthermore, the PinG model is extended to include the treatment of volume sources to simulate fugitive VOC emissions. The new PinG model is evaluated over Greater Paris during July 2009. Model performance is satisfactory for O3, PM2.5 and most PM2.5 components. Two industrial sources, a coal-fired power plant and an oil refinery, are simulated with the PinG model. The characteristics of the sources (stack height and diameter, exhaust temperature and velocity) govern the surface concentrations of primary pollutants (NOx, SO2 and VOC). O3 concentrations are impacted differently near the power plant than near the refinery, because of the presence of VOC emissions at the latter. The formation of sulfate is influenced by both the dispersion of SO2 and the oxidant concentration; however, the former tends to dominate in the simulations presented here. The impact of PinG modeling on the formation of secondary organic aerosols (SOA) is small and results mostly from the effect of different oxidant concentrations on biogenic SOA formation. The investigation of the criteria for injecting plumes into the host model (fixed travel time and/or puff size) shows that a size-based criterion is recommended to treat the formation of secondary aerosols (sulfate, nitrate, and ammonium), in particular, farther downwind of the sources (from about 15 km). The impacts of the PinG modeling are less significant in a simulation with a coarse grid size (10 km) than with a fine grid size (2 km), because the concentrations of the species emitted from the PinG sources are relatively less important compared to background concentrations when injected into the host model.

  20. Preliminary evaluation of a novel smoking system: effects on subjective and physiological measures and on smoking behavior.

    PubMed

    Buchhalter, A R; Eissenberg, T

    2000-02-01

    Tobacco companies are responding to public pressure to market less dangerous and aversive products by developing novel smoking systems. The short- and long-term effects of these systems must be evaluated to determine the risks inherent in their use. One such system, the Accord, uses a hand-held device to heat tobacco electronically and is marketed as a means to reduce second-hand smoke. In this study 10 cigarette smokers (> or = 10 cigarettes per day) were recruited to evaluate the short-term effects produced when using this system. Subjects abstained from smoking for at least 8 h before participating in two experimental sessions where they smoked either their usual brand or used the Accord at 30-min intervals for 2 hours. Subject-rated measures of tobacco withdrawal and craving, physiological measures, and smoking behavior were assessed within each session. Results show that, when using the Accord, the magnitude of smoking-induced craving reductions and the physiological effects of smoking were less, and puff volume and frequency were greater than when subjects smoked their own brand of cigarettes. The expired air carbon monoxide increases observed after smoking own brand cigarettes did not occur after using the Accord. The novel system does not provide maximal withdrawal suppression and produces little increase in expired air carbon monoxide; physiological data suggest that the novel system may deliver nicotine less efficiently than normally marketed cigarettes. Smokers using the Accord system may smoke more often or more intensely to compensate for decreased withdrawal suppression and/or nicotine delivery.

  1. A Bayesian method to rank different model forecasts of the same volcanic ash cloud: Chapter 24

    USGS Publications Warehouse

    Denlinger, Roger P.; Webley, P.; Mastin, Larry G.; Schwaiger, Hans F.

    2012-01-01

    Volcanic eruptions often spew fine ash high into the atmosphere, where it is carried downwind, forming long ash clouds that disrupt air traffic and pose a hazard to air travel. To mitigate such hazards, the community studying ash hazards must assess risk of ash ingestion for any flight path and provide robust and accurate forecasts of volcanic ash dispersal. We provide a quantitative and objective method to evaluate the efficacy of ash dispersal estimates from different models, using Bayes theorem to assess the predictions that each model makes about ash dispersal. We incorporate model and measurement uncertainty and produce a posterior probability for model input parameters. The integral of the posterior over all possible combinations of model inputs determines the evidence for each model and is used to compare models. We compare two different types of transport models, an Eulerian model (Ash3d) and a Langrangian model (PUFF), as applied to the 2010 eruptions of Eyjafjallajökull volcano in Iceland. The evidence for each model benefits from common physical characteristics of ash dispersal from an eruption column and provides a measure of how well each model forecasts cloud transport. Given the complexity of the wind fields, we find that the differences between these models depend upon the differences in the way the models disperse ash into the wind from the source plume. With continued observation, the accuracy of the estimates made by each model increases, increasing the efficacy of each model’s ability to simulate ash dispersal.

  2. Induction of Metallothionein Expression After Exposure to Conventional Cigarette Smoke but Not Electronic Cigarette (ECIG)-Generated Aerosol in Caenorhabditis elegans

    PubMed Central

    Cobb, Eric; Hall, Julie; Palazzolo, Dominic L.

    2018-01-01

    Aim: With the invention of electronic cigarettes (ECIG), many questions have been raised regarding their safety as an alternative to smoking conventional cigarettes. Conventional cigarette smoke contains a variety of toxicants including heavy metals. However, ECIG-generated aerosol contains only trace amounts of metals, adding to the argument for it being a safer alternative. In response to heavy metal exposure, metallothioneins are induced in cells to help store the metal, detoxify the body, and are also known responders to oxidative stress. In an attempt to add to the evaluation of the safety of ECIGs, metallothionein expression was quantified using the nematode Caenorhabditis elegans as an assessment of stress induced cellular damage caused by exposure. Methods: Adult nematodes were exposed to either ECIG aerosol or conventional cigarette smoke at doses of 15, 30, and 45 puffs, the equivalent of one, two, and three cigarettes, respectively. Movement, survival, and stress-induced sleep were assessed for up to 24 h after exposure. Relative expression levels for mtl-1 and mtl-2, C. elegans metallothionein genes, were analyzed after 1, 5, and 24 h post exposure using quantitative RT-PCR. Results: Nematodes exposed to conventional cigarette smoke underwent stress-induced sleep in a dose dependent manner with animals recovering to values within the range of air control after 5 h post exposure. Those exposed to ECIG aerosol did not undergo stress-induced sleep and were indistinguishable from controls. The expression of mtl-1 increased in a dose and time dependent manner in C. elegans exposed to conventional cigarette smoke, with a maximum expression observed at 5 h post exposure of 45 puffs. No induction of mtl-2 was observed in any animals. Additionally, ECIG aerosol did not induce expression of mtl-1 and mtl-2 at levels different than those of untreated. Conclusion: ECIG aerosol failed to induce a stress response in C. elegans. In contrast, conventional cigarette smoke induced the production of mtl-1 in a manner that correlates with the induction of stress-induced sleep suggesting a stress response to damage. The lack of cellular stress response to ECIG aerosol suggests it may be a safer alternative to conventional cigarettes. PMID:29740339

  3. Development and application of a reactive plume-in-grid model: evaluation over Greater Paris

    NASA Astrophysics Data System (ADS)

    Korsakissok, I.; Mallet, V.

    2010-02-01

    Emissions from major point sources are badly represented by classical Eulerian models. An overestimation of the horizontal plume dilution, a bad representation of the vertical diffusion as well as an incorrect estimate of the chemical reaction rates are the main limitations of such models in the vicinity of major point sources. The plume-in-grid method is a multiscale modeling technique that couples a local-scale Gaussian puff model with an Eulerian model in order to better represent these emissions. We present the plume-in-grid model developed in the air quality modeling system Polyphemus, with full gaseous chemistry. The model is evaluated on the metropolitan Île-de-France region, during six months (summer 2001). The subgrid-scale treatment is used for 89 major point sources, a selection based on the emission rates of NOx and SO2. Results with and without the subgrid treatment of point emissions are compared, and their performance by comparison to the observations at measurement stations is assessed. A sensitivity study is also carried out, on several local-scale parameters as well as on the vertical diffusion within the urban area. Primary pollutants are shown to be the most impacted by the plume-in-grid treatment, with a decrease in RMSE by up to about -17% for SO2 and -7% for NO at measurement stations. SO2 is the most impacted pollutant, since the point sources account for an important part of the total SO2 emissions, whereas NOx emissions are mostly due to traffic. The spatial impact of the subgrid treatment is localized in the vicinity of the sources, especially for reactive species (NOx and O3). Reactive species are mostly sensitive to the local-scale parameters, such as the time step between two puff emissions which influences the in-plume chemical reactions, whereas the almost-passive species SO2 is more sensitive to the injection time, which determines the duration of the subgrid-scale treatment. Future developments include an extension to handle aerosol chemistry, and an application to the modeling of line sources in order to use the subgrid treatment with road emissions. The latter is expected to lead to more striking results, due to the importance of traffic emissions for the pollutants of interest.

  4. Correlation of volatile carbonyl yields emitted by e-cigarettes with the temperature of the heating coil and the perceived sensorial quality of the generated vapours.

    PubMed

    Geiss, Otmar; Bianchi, Ivana; Barrero-Moreno, Josefa

    2016-05-01

    E-liquids generally contain four main components: nicotine, flavours, water and carrier liquids. The carrier liquid dissolves flavours and nicotine and vaporises at a certain temperature on the atomizer of the e-cigarette. Propylene glycol and glycerol, the principal carriers used in e-liquids, undergo decomposition in contact with the atomizer heating-coil forming volatile carbonyls. Some of these, such as formaldehyde, acetaldehyde and acrolein, are of concern due to their adverse impact on human health when inhaled at sufficient concentrations. The aim of this study was to correlate the yield of volatile carbonyls emitted by e-cigarettes with the temperature of the heating coil. For this purpose, a popular commercial e-liquid was machine-vaped on a third generation e-cigarette which allowed the variation of the output wattage (5-25W) and therefore the heat generated on the atomizer heating-coil. The temperature of the heating-coil was determined by infrared thermography and the vapour generated at each temperature underwent subjective sensorial quality evaluation by an experienced vaper. A steep increase in the generated carbonyls was observed when applying a battery-output of at least 15W corresponding to 200-250°C on the heating coil. However, when considering concentrations in each inhaled puff, the short-term indoor air guideline value for formaldehyde was already exceeded at the lowest wattage of 5W, which is the wattage applied in most 2nd generation e-cigarettes. Concentrations of acetaldehyde in each puff were several times below the short-term irritation threshold value for humans. Acrolein was only detected from 20W upwards. The negative sensorial quality evaluation by the volunteering vaper of the vapour generated at 20W demonstrated the unlikelihood that such a wattage would be realistically set by a vaper. This study highlights the importance to develop standardised testing methods for the assessment of carbonyl-emissions and emissions of other potentially harmful compounds from e-cigarettes. The wide variety and variability of products available on the market make the development of such methods and the associated standardised testing conditions particularly demanding. Copyright © 2016 The Authors. Published by Elsevier GmbH.. All rights reserved.

  5. Helping Teenagers Stop Smoking: Comparative Observations across Youth Settings in Cardiff

    ERIC Educational Resources Information Center

    Bowles, Hannah; Maher, Alison; Sage, Robert

    2009-01-01

    Objective: This paper presents comparative observations between schools/colleges, youth centres, and specialist youth provision, in relation to delivery of the 2tuff2puff six-week smoking cessation and awareness programme to young people in Cardiff. Design: A six-week smoking cessation programme was delivered to 12-23 year olds in various youth…

  6. We Huff and Puff: The Parameters and the Program of Aerobics for Children under Five.

    ERIC Educational Resources Information Center

    Eastman, Wayne

    In today's society, young children have few experiences with aerobic activities, a pattern of exercise traditionally reserved for adults. This paper discusses how aerobic exercises can be used in a preschool environment, arguing that such activities are best presented using a thematic approach so that young children can form impressions about…

  7. Food Service Worker. Instructional Modules for Food Management, Production and Services. Modules 35-52. Competency Based Curriculum.

    ERIC Educational Resources Information Center

    Tennessee Univ., Knoxville. Dept. of Vocational-Technical Education.

    These 18 teacher modules are part of a curriculum dealing with food management, production, and services that was developed for use in secondary and postsecondary vocational programs in Tennessee. Covered in the individual modules are quickbreads, pies, icings and toppings, specialty cakes, specialty desserts, yeast products, cream puff and puff…

  8. Measuring ocular characteristics after gel injection adjustable keratoplasty (GIAK) in the rabbit

    NASA Astrophysics Data System (ADS)

    Comander, Jason I.; Parel, Jean-Marie A.; Simon, Gabriel; Takesue, Yoshiko; Villain, Franck L.

    1995-05-01

    Gel Injection Adjustable Keratoplasty (GIAK) is a refractive surgery procedure which uses an ocular ring implant made of a polyethylene oxide hydrogel to cause a refractive change in the cornea. Unlike laser photo refractive keratectomy, GIAK does not interfere with the central cornea because the ring lies around the optical axis. Thus, vision can be assessed immediately after surgery. Our in vivo study was designed to quantify GIAK's effects on tissues, the biocompatibility of the polymer and in the process investigate which ocular changes in the rabbit model can be monitored with precision using current technology. Thirty-two young rabbits underwent a delamination in one eye, 22 of which were injected with a new polymeric gel. Corneal topography, keratometry, pachymetry, and tonometry were performed on both eyes for up to 105 days. All corneas flattened with growth. In GIAK animals, we found an average flattening of 6.51 +/- 1.23 diopters (p < 0.0001) relative to the fellow eye. No statistically significant regression over the 102 days was observed. Intraocular pressure dropped slightly by 0.69 +/- 1.21 mmHg (p equals 0.025), a clinically insignificant value, while no significant change was detected in corneal thickness. Keratometry can be tracked in rabbits after GIAK surgery from POD 1. Measuring unoperated fellow eyes allows for the effects of surgery to be assessed without bias from growth. Using this protocol, GIAK was shown to be stable. It was more difficult to draw conclusions from pachymetry, tonometry, and topography data.

  9. [Comparison between Goldmann, Icare Pro and Corvis ST tonometry].

    PubMed

    Bañeros-Rojas, P; Martinez de la Casa, J M; Arribas-Pardo, P; Berrozpe-Villabona, C; Toro-Utrera, P; García-Feijoó, J

    2014-07-01

    To compare intraocular pressure (IOP) between the new non-contact tonometer Corvis ST (CST), the Goldmann applanation tonometry (GAT) and Icare Pro rebound tonometer (PRO). A total of 178 eyes of 178 healthy subjects were selected for the study. Measurements of IOP were made in a random order with GAT, PRO and CST. Central corneal thickness (CCT) was determined by ultrasound pachymetry. The mean of three valid measurements of each variable was used in the statistical analysis. The relationship between the tonometers was established using Bland-Altman plots. Mean IOP was 15.5 ± 2.8 mmHg for GAT, 15.4 ± 2.8 mmHg for CST, and 14.6 ± 2.3 mmHg for PRO. The mean differences between pairs of tonometers were: GAT-PRO=0.9 ± 1.7 mmHg (P<.001), GAT-CST: 0.1 ± 2.2 (P=.398), and PRO-CST: -0.8 ±-0.7 mmHg, p<0.001. A positive relationship was detected between CCT and the three tonometers: GAT: r=0.325, P<.001; PRO: r = 0.385, P<.001, and CST: r = 0.428; P<.001. The differences found between PRO and GAT were significantly higher than those found between CST and GAT, which showed non-significant differences. The measurements of the three tonometers were affected by the CCT. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  10. A comparison of Fluoracaine and Fluorox on corneal epithelial cell desquamation after Goldmann Applanation Tonometry.

    PubMed

    Yeung, K K; Kageyama, J Y; Carnevali, T

    2000-01-01

    The purpose of this study was to quality the frequency and amount of corneal desquamation from a sodium fluorescein/proparacaine combination (Fluoracaine) as compared with sodium fluorescein/benoxinate combination ophthalmic solution (Fluorox) after Goldmann Applanation Tonometry. One drop of Fluoracaine was randomly instilled into one eye and one drop of Fluorox was instilled into the opposite eye of the same patient. Intraocular pressures (IOPs) by GAT and tear break-up times (TBUTs) were taken. Corneal stinging was compared. Corneal integrity by Cornea and Contact Lens Research Unit (CCLRU) standards was evaluated at 0, 3, 7, 10, 15, and 20 minutes after instillation of the ophthalmic solutions. Sixty eyes of 30 patients were observed Forty-seven percent of the patients reported Fluorox to string more than Fluoracaine; 23% of the patients reported that Fluoracaine stings more than Fluorox; and 30% the patients reported no difference. Average TBUTs were 6.87 and 7.17 seconds with Fluoracaine and Fluorox, respectively. Fluoracaine produced micro- and macropunctate keratitis of the superficial epithelium in 31% to 45% of the cornea. Fluorox caused superficial micropunctate keratitis in about 16% to 30% of the cornea. At 20 minutes, all eyes with Fluoracaine and all eyes but one with Fluorox had corneal desquamation. Fluoracaine causes marginally less stinging--however, clinically and statistically more corneal desquamation--than Fluorox after GAT. Corneal integrity after use of Fluoracaine should be evaluated even 20 minutes after GAT procedures for corneal disruption.

  11. The active titration method for measuring local hydroxyl radical concentration

    NASA Technical Reports Server (NTRS)

    Sprengnether, Michele; Prinn, Ronald G.

    1994-01-01

    We are developing a method for measuring ambient OH by monitoring its rate of reaction with a chemical species. Our technique involves the local, instantaneous release of a mixture of saturated cyclic hydrocarbons (titrants) and perfluorocarbons (dispersants). These species must not normally be present in ambient air above the part per trillion concentration. We then track the mixture downwind using a real-time portable ECD tracer instrument. We collect air samples in canisters every few minutes for roughly one hour. We then return to the laboratory and analyze our air samples to determine the ratios of the titrant to dispersant concentrations. The trends in these ratios give us the ambient OH concentration from the relation: dlnR/dt = -k(OH). A successful measurement of OH requires that the trends in these ratios be measureable. We must not perturb ambient OH concentrations. The titrant to dispersant ratio must be spatially invariant. Finally, heterogeneous reactions of our titrant and dispersant species must be negligible relative to the titrant reaction with OH. We have conducted laboratory studies of our ability to measure the titrant to dispersant ratios as a function of concentration down to the few part per trillion concentration. We have subsequently used these results in a gaussian puff model to estimate our expected uncertainty in a field measurement of OH. Our results indicate that under a range of atmospheric conditions we expect to be able to measure OH with a sensitivity of 3x10(exp 5) cm(exp -3). In our most optimistic scenarios, we obtain a sensitivity of 1x10(exp 5) cm(exp -3). These sensitivity values reflect our anticipated ability to measure the ratio trends. However, because we are also using a rate constant to obtain our (OH) from this ratio trend, our accuracy cannot be better than that of the rate constant, which we expect to be about 20 percent.

  12. An integrated simulation and optimization approach for managing human health risks of atmospheric pollutants by coal-fired power plants.

    PubMed

    Dai, C; Cai, X H; Cai, Y P; Guo, H C; Sun, W; Tan, Q; Huang, G H

    2014-06-01

    This research developed a simulation-aided nonlinear programming model (SNPM). This model incorporated the consideration of pollutant dispersion modeling, and the management of coal blending and the related human health risks within a general modeling framework In SNPM, the simulation effort (i.e., California puff [CALPUFF]) was used to forecast the fate of air pollutants for quantifying the health risk under various conditions, while the optimization studies were to identify the optimal coal blending strategies from a number of alternatives. To solve the model, a surrogate-based indirect search approach was proposed, where the support vector regression (SVR) was used to create a set of easy-to-use and rapid-response surrogates for identifying the function relationships between coal-blending operating conditions and health risks. Through replacing the CALPUFF and the corresponding hazard quotient equation with the surrogates, the computation efficiency could be improved. The developed SNPM was applied to minimize the human health risk associated with air pollutants discharged from Gaojing and Shijingshan power plants in the west of Beijing. Solution results indicated that it could be used for reducing the health risk of the public in the vicinity of the two power plants, identifying desired coal blending strategies for decision makers, and considering a proper balance between coal purchase cost and human health risk. A simulation-aided nonlinear programming model (SNPM) is developed. It integrates the advantages of CALPUFF and nonlinear programming model. To solve the model, a surrogate-based indirect search approach based on the combination of support vector regression and genetic algorithm is proposed. SNPM is applied to reduce the health risk caused by air pollutants discharged from Gaojing and Shijingshan power plants in the west of Beijing. Solution results indicate that it is useful for generating coal blending schemes, reducing the health risk of the public, reflecting the trade-offbetween coal purchase cost and health risk.

  13. 33 CFR 334.410 - Albemarle Sound, Pamlico Sound, and adjacent waters, NC; danger zones for naval aircraft operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... bombs which contain only small explosive charges for producing smoke puffs to mark points of impact. All... operations. Dummy ammunition, waterfilled or smoke bombs and inert rockets will be used, except during wartime when live ammunition, bombs and rockets may be used. The area will be open to navigation except...

  14. Plasma shut-down with fast impurity puff on ASDEX Upgrade

    NASA Astrophysics Data System (ADS)

    Pautasso, G.; Fuchs, C. J.; Gruber, O.; Maggi, C. F.; Maraschek, M.; Pütterich, T.; Rohde, V.; Wittmann, C.; Wolfrum, E.; Cierpka, P.; Beck, M.; ASDEX Upgrade Team

    2007-08-01

    The massive injection of impurity gas into a plasma has been proved to reduce forces and localized thermal loads caused by disruptions in tokamaks. This mitigation system is routinely used on ASDEX Upgrade to shut down plasmas with a locked mode. The plasma response to impurity injection and the mechanism of reduction of the mechanical forces is discussed in the paper.

  15. 33 CFR 334.410 - Albemarle Sound, Pamlico Sound, and adjacent waters, NC; danger zones for naval aircraft operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... bombs which contain only small explosive charges for producing smoke puffs to mark points of impact. All... operations. Dummy ammunition, waterfilled or smoke bombs and inert rockets will be used, except during wartime when live ammunition, bombs and rockets may be used. The area will be open to navigation except...

  16. 33 CFR 334.410 - Albemarle Sound, Pamlico Sound, and adjacent waters, NC; danger zones for naval aircraft operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... bombs which contain only small explosive charges for producing smoke puffs to mark points of impact. All... operations. Dummy ammunition, waterfilled or smoke bombs and inert rockets will be used, except during wartime when live ammunition, bombs and rockets may be used. The area will be open to navigation except...

  17. 33 CFR 334.410 - Albemarle Sound, Pamlico Sound, and adjacent waters, NC; danger zones for naval aircraft operations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... bombs which contain only small explosive charges for producing smoke puffs to mark points of impact. All... operations. Dummy ammunition, waterfilled or smoke bombs and inert rockets will be used, except during wartime when live ammunition, bombs and rockets may be used. The area will be open to navigation except...

  18. SRI PUFF 8 Computer Program for One-Dimensional Stress Wave Propagation

    DTIC Science & Technology

    1980-03-01

    raial product. UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE (Tfhen Data Entered) REPORT DOCUMENTATION PAGE READ INSTRUCTIONS BEFORE COMPLETING...EDITION OF I NOV 6S (S OBSOLETE UNCLASSIFIED SECURITY CLASSIFICATIOK OF THIS PAGE (When Data Entered) UNCLASSIFIED SECURITY CLASSIFICATION OF THIS...aspects of wave propagation calculations. UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGEfWhen Data Entered) FOREWORD This volume constitutes a

  19. Application of Human Augmentics: A Persuasive Asthma Inhaler.

    PubMed

    Grossman, Brent; Conner, Steve; Mosnaim, Giselle; Albers, Joshua; Leigh, Jason; Jones, Steve; Kenyon, Robert

    2017-03-01

    This article describes a tailored health intervention delivered on a mobile phone platform, integrating low-literacy design strategies and basic principles of behavior change, to promote increased adherence and asthma control among underserved minority adolescents. We based the intervention and design principles on theories of Human Augmentics and the Elaboration Likelihood Model. We tested the efficacy of using electronic monitoring devices that incorporate informative and persuasive elements to improve adherence to a prescribed daily medication regimen intended to reduce use of asthma rescue medications. We describe the theoretical framework, hardware and software systems, and results of user testing for design purposes and a clinical pilot study incorporating use of the device and software by the targeted population. The results of the clinical pilot study showed an 83% completion rate for the treatment as well as improved adherence. Of note, 8% and 58% of participants achieved clinically significant adherence targets at baseline and last week of the study, respectively. Rescue asthma medication use decreased from a median of 3 puffs per week at baseline to 0 puffs per week during the last week of the study. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Stable isotope studies of nicotine kinetics and bioavailability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benowitz, N.L.; Jacob, P. 3d.; Denaro, C.

    1991-03-01

    The stable isotope-labeled compound 3',3'-dideuteronicotine was used to investigate the disposition kinetics of nicotine in smokers, the systemic absorption of nicotine from cigarette smoke, and the bioavailability of nicotine ingested as oral capsules. Blood levels of labeled nicotine could be measured for 9 hours after a 30-minute intravenous infusion. Analysis of disposition kinetics in 10 healthy men revealed a multiexponential decline after the end of an infusion, with an elimination half-life averaging 203 minutes. This half-life was longer than that previously reported, indicating the presence of a shallow elimination phase. Plasma clearance averaged 14.6 ml/min/kg. The average intake of nicotinemore » per cigarette was 2.29 mg. A cigarette smoke-monitoring system that directly measured particulate matter in smoke was evaluated in these subjects. Total particulate matter, number of puffs on the cigarette, total puff volume, and time of puffing correlated with the intake of nicotine from smoking. The oral bioavailability of nicotine averaged 44%. This bioavailability is higher than expected based on the systemic clearance of nicotine and suggests that there may be significant extrahepatic metabolism of nicotine.« less

  1. Effects of fenoterol and ipratropium on respiratory resistance of asthmatics after tracheal intubation.

    PubMed

    Wu, R S; Wu, K C; Wong, T K; Tsai, Y H; Cheng, R K; Bishop, M J; Tan, P P

    2000-03-01

    We have studied the effects of a beta-agonist, fenoterol, and a cholinergic antagonist, ipratropium, on post-intubation total respiratory system resistance (Rrs) in asthmatics who developed increased Rrs after tracheal intubation. Sixteen stable asthmatics in whom Rrs increased after intubation were allocated randomly to receive either 10 puffs of fenoterol (group F) or 10 puffs of ipratropium (group IB) via a metered dose inhaler 5 min after intubation. Anaesthesia was induced and maintained with propofol i.v. Rrs was recorded before treatment and again 5, 15 and 30 min after treatment. Rrs decreased significantly from pretreatment values by mean 53 (SD 8)%, 53 (7)% and 58 (6)% at 5, 15 and 30 min, respectively, in group F, but declined by only 12 (6)%, 15 (4)% and 17 (5)% in group IB. At all times after treatment, patients in the fenoterol group had significantly lower Rrs values than those in the ipratropium group. We conclude that increased Rrs after tracheal intubation in asthmatics can be reduced effectively by treatment with fenoterol. A secondary finding of our study was that even after induction of anaesthesia with propofol, patients with a history of asthma may develop high Rrs.

  2. Diagnosis of high-intensity pulsed heavy ion beam generated by a novel magnetically insulated diode with gas puff plasma gun.

    PubMed

    Ito, H; Miyake, H; Masugata, K

    2008-10-01

    Intense pulsed heavy ion beam is expected to be applied to materials processing including surface modification and ion implantation. For those applications, it is very important to generate high-purity ion beams with various ion species. For this purpose, we have developed a new type of a magnetically insulated ion diode with an active ion source of a gas puff plasma gun. When the ion diode was operated at a diode voltage of about 190 kV, a diode current of about 15 kA, and a pulse duration of about 100 ns, the ion beam with an ion current density of 54 A/cm(2) was obtained at 50 mm downstream from the anode. By evaluating the ion species and the energy spectrum of the ion beam via a Thomson parabola spectrometer, it was confirmed that the ion beam consists of nitrogen ions (N(+) and N(2+)) of energy of 100-400 keV and the proton impurities of energy of 90-200 keV. The purity of the beam was evaluated to be 94%. The high-purity pulsed nitrogen ion beam was successfully obtained by the developed ion diode system.

  3. In-situ gamma-ray assay of the west cell line in the 235-F plutonium fuel form facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Couture, A. H.; Diprete, D.

    On August 29th, 2013, scientists from SRNL took a series of in-situ gamma-ray measurements in the maintenance trench beneath Cells 6-9 on the west line of the PuFF facility using an uncollimated, highpurity germanium detector. The detector efficiency was estimated using a combination of MCNP simulations and empirical measurements. Data analysis was performed using three gamma-rays emitted by Pu-238 (99.85 keV, 152.7 keV, and 766.4 keV) providing three independent estimates of the mass of Pu-238 holdup in each of the cells. The weighted mean of these three results was used as the best estimate of Pu-238 holdup in the Westmore » Cell Line of PuFF. The results of the assay measurements are found in the table below along with the results from the scoping assay performed in 2006. All uncertainties in this table (as well as the rest of the report) are given as 1σ. The total holdup in the West Cell Line was 2.4 ± 0.7 grams. This result is 0.6 g higher than the previous estimate, a 0.4σ difference.« less

  4. Smoking topography and abstinence in adult female smokers

    PubMed Central

    McClure, Erin A.; Saladin, Michael E.; Baker, Nathaniel L.; Carpenter, Matthew J.; Gray, Kevin M.

    2013-01-01

    Preliminary evidence, within both adults and adolescents, suggests that the intensity with which cigarettes are smoked (i.e. smoking topography) is predictive of success during a cessation attempt. These reports have also shown topography to be superior compared to other variables, such as cigarettes per day, in the prediction of abstinence. The possibility that gender may influence this predictive relationship has not been evaluated, but may be clinically useful in tailoring gender-specific interventions. Within the context of a clinical trial for smoking cessation among women, adult daily smokers completed a laboratory session that included a 1-hour ad-libitum smoking period in which measures of topography were collected (N=135). Participants were then randomized to active medication (nicotine patch vs. varenicline) and abstinence was monitored for 4 weeks. Among all smoking topography measures and all abstinence outcomes, a moderate association was found between longer puff duration and greater puff volume and continued smoking during the active 4-week treatment phase, but only within the nicotine patch group. Based on the weak topography-abstinence relationship among female smokers found in the current study, future studies should focus on explicit gender comparisons to examine if these associations are specific to or more robust in male smokers. PMID:24018226

  5. Dual Use of Cigarettes, Little Cigars, Cigarillos, and Large Cigars: Smoking Topography and Toxicant Exposure.

    PubMed

    Pickworth, Wallace B; Rosenberry, Zachary R; O'Grady, Kevin E; Koszowski, Bartosz

    2017-04-01

    Smoking topography variables and toxicant exposure (plasma nicotine and exhaled CO) were examined in 3 groups of study participants that smoked both cigarettes and either filtered little cigars (Winchester), cigarillos (Black & Mild), or large cigars (Phillies Blunt). Laboratory ad lib smoking of the cigar products was collected with a smoking puff analyzer; plasma levels of nicotine and exhaled CO were collected before and after smoking. Although there were no statistically significant differences in demographic and cigarette smoking topography among the groups, there were significant differences in how the different cigar products were smoked. Plasma nicotine boost was similar after all products but exhaled CO was greater after the cigarillo and large cigar than the little cigar. Some of the differences were due to the differences in article size but other differences were apparent even after adjustment for the amount of tobacco burned or the mouth intake (puff volume). The topography findings of differences among products challenge the practice of grouping cigars as a single entity in surveys, regulatory decisions, and discussions of toxicant exposure. The results add to the discussion of distinctions among products in the scientific assessment of public health risk and regulatory decisions.

  6. Measurement of an electronic cigarette aerosol size distribution during a puff

    NASA Astrophysics Data System (ADS)

    Belka, Miloslav; Lizal, Frantisek; Jedelsky, Jan; Jicha, Miroslav; Pospisil, Jiri

    Electronic cigarettes (e-cigarettes) have become very popular recently because they are marketed as a healthier alternative to tobacco smoking and as a useful tool to smoking cessation. E-cigarettes use a heating element to create an aerosol from a solution usually consisting of propylene glycol, glycerol, and nicotine. Despite the wide spread of e-cigarettes, information about aerosol size distributions is rather sparse. This can be caused by the relative newness of e-cigarettes and by the difficulty of the measurements, in which one has to deal with high concentration aerosol containing volatile compounds. Therefore, we assembled an experimental setup for size measurements of e-cigarette aerosol in conjunction with a piston based machine in order to simulate a typical puff. A TSI scanning mobility particle sizer 3936 was employed to provide information about particle concentrations and sizes. An e-cigarette commercially available on the Czech Republic market was tested and the results were compared with a conventional tobacco cigarette. The particles emitted from the e-cigarette were smaller than those of the conventional cigarette having a CMD of 150 and 200 nm. However, the total concentration of particles from e-cigarette was higher.

  7. Neutron Activation Diagnostics in Deuterium Gas-Puff Experiments on the 3 MA GIT-12 Z-Pinch

    NASA Astrophysics Data System (ADS)

    Cikhardt, J.; Klir, D.; Rezac, K.; Cikhardtova, B.; Kravarik, J.; Kubes, P.; Sila, O.; Shishlov, A. V.; Cherdizov, R. K.; Fursov, F. I.; Kokshenev, V. A.; Kurmaev, N. E.; Labetsky, A. Yu; Ratakhin, N. A.; Dudkin, G. N.; Garapatsky, A. A.; Padalko, V. N.; Varlachev, V. A.; Turek, K.

    2016-10-01

    The experiments with a deuterium z-pinch on the GIT-12 generator at IHCE in Tomsk were performed in the frame of the Czech-Russian agreement. A set of neutron diagnostics included scintillation time-of-flight detectors, bubble detectors, and several kinds of threshold nuclear activation detectors in the order to obtain information about the yield, anisotropy, and spectrum of the neutrons produced by a deuterium gas-puff. The average neutron yield in these experiments was of the order of 1012 neutrons per a single shot. The energy spectrum of the produced neutrons was evaluated using neutron time-of-flight detectors and a set of neutron activation detectors. Because the deuterons in the pinch achieve multi-MeV energies, non-DD neutrons are produced by nuclear reactions of deuterons with a stainless steel vacuum chamber and aluminum components of diagnostics inside the chamber. An estimated number of the non-DD was of the order of 1011. GACR (Grant No. 16-07036S), CME (Grant Nos. LD14089, LG13029, and LH13283), MESRF (Grant No. RFMEFI59114X0001), IAEA (Grant No. RC17088), CTU (Grant No. SGS 16/223/OHK3/3T/13).

  8. A compact "water-window" microscope with 60-nm spatial resolution based on a double stream gas-puff target and Fresnel zone plate optics

    NASA Astrophysics Data System (ADS)

    Wachulak, Przemyslaw; Torrisi, Alfio; Nawaz, Muhammad F.; Adjei, Daniel; Bartnik, Andrzej; Kostecki, Jerzy; Wegrzynski, Łukasz; Vondrová, Šárka; Turňová, Jana; Fok, Tomasz; Jančarek, Alexandr; Fiedorowicz, Henryk

    2015-05-01

    Radiation with shorter illumination wavelength allows for extension of the diffraction limit towards nanometer scale, which is a straightforward way to significantly improve a spatial resolution in photon based microscopes. Soft X-ray (SXR) radiation, from the so called "water window" spectral range, λ=2.3-4.4 nm, which is particularly suitable for biological imaging due to natural optical contrast, providing much better spatial resolution than one obtained with visible light microscopes. The high contrast is obtained because of selective absorption of radiation by carbon and water, being constituents of the biological samples. We present a desk-top system, capable of resolving 60 nm features in few seconds exposure time. We exploit the advantages of a compact, laser-plasma SXR source, based on a double stream nitrogen gas puff target, developed at the Institute of Optoelectronics, Military University of Technology. The source, emitting quasi-monochromatic, incoherent radiation, in the "water widow" spectral range at λ = 2.88 nm, is coupled with ellipsoidal, grazing incidence condenser and Fresnel zone plate objective. The construction of the microscope with some recent images of test and real samples will be presented and discussed.

  9. Evaluation of a glaucoma patient

    PubMed Central

    Thomas, Ravi; Loibl, Klaus; Parikh, Rajul

    2011-01-01

    The diagnosis of glaucoma is usually made clinically and requires a comprehensive eye examination, including slit lamp, applanation tonometry, gonioscopy and dilated stereoscopic evaluation of the optic disc and retina. Automated perimetry is obtained if glaucoma is suspected. This establishes the presence of functional damage and provides a baseline for follow-up. Imaging techniques are not essential for the diagnosis but may have a role to play in the follow-up. We recommend a comprehensive eye examination for every clinic patient with the objective of detecting all potentially sight-threatening diseases, including glaucoma. PMID:21150033

  10. Source Parameter Estimation using the Second-order Closure Integrated Puff Model

    DTIC Science & Technology

    The sensor measurements are categorized as triggered and non-triggered based on the recorded concentration measurements and a threshold...concentration value. Using each measured value, sources of adjoint material are created from the triggered and non-triggered sensors, and the adjoint transport...equations are solved to predict the adjoint concentration fields. The adjoint source strength is inversely proportional to the concentration measurement

  11. Smoking Through a Topography Device Diminishes Some of the Acute Rewarding Effects of Smoking.

    PubMed

    Ross, Kathryn C; Juliano, Laura M

    2016-05-01

    Smoking topography (ST) devices are an important methodological tool for quantifying puffing behavior (eg, puff volume, puff velocity) as well as identifying puffing differences across individuals and situations. Available ST devices are designed such that the smoker's mouth and hands have direct contact with the device rather than the cigarette itself. Given the importance of the sensorimotor aspects of cigarette smoking in smoking reward, it is possible that ST devices may interfere with the acute rewarding effects of smoking. Despite the methodological importance of this issue, few studies have directly compared subjective reactions to smoking through a topography device to naturalistic smoking. Smokers (N = 58; 38% female) smoked their preferred brand of cigarettes one time through a portable topography device and one time naturalistically, in counterbalanced order across two laboratory sessions. Smoking behavior (eg, number of puffs) and subjective effects (eg, urge reduction, affect, smoking satisfaction) were assessed. Negative affect reduction was greater in the natural smoking condition relative to the topography condition, but differences were not significant on measures of urge, withdrawal, or positive affect. Self-reported smoking satisfaction, enjoyment of respiratory tract sensations, psychological reward, craving reduction, and other rewarding effects of smoking were also significantly greater in the naturalistic smoking condition. The effects of using a ST device on the smoking experience should be considered when it is used in research as it may diminish some of the rewarding effects of smoking. When considering the inclusion of a smoking topography device in one's research, it is important to know if use of that device will alter the smoker's experience. This study assessed affective and subjective reactions to smoking through a topography device compared to naturalistic smoking. We found that smoking satisfaction, psychological reward, enjoyment of respiratory tract sensations and other rewarding effects were all diminished when smoking through the topography device. The effects of using a smoking topography device on the smoking experience should be considered when it is used in future research. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Smoking Through a Topography Device Diminishes Some of the Acute Rewarding Effects of Smoking

    PubMed Central

    Juliano, Laura M.

    2016-01-01

    Abstract Background: Smoking topography (ST) devices are an important methodological tool for quantifying puffing behavior (eg, puff volume, puff velocity) as well as identifying puffing differences across individuals and situations. Available ST devices are designed such that the smoker’s mouth and hands have direct contact with the device rather than the cigarette itself. Given the importance of the sensorimotor aspects of cigarette smoking in smoking reward, it is possible that ST devices may interfere with the acute rewarding effects of smoking. Despite the methodological importance of this issue, few studies have directly compared subjective reactions to smoking through a topography device to naturalistic smoking. Methods: Smokers ( N = 58; 38% female) smoked their preferred brand of cigarettes one time through a portable topography device and one time naturalistically, in counterbalanced order across two laboratory sessions. Smoking behavior (eg, number of puffs) and subjective effects (eg, urge reduction, affect, smoking satisfaction) were assessed. Results: Negative affect reduction was greater in the natural smoking condition relative to the topography condition, but differences were not significant on measures of urge, withdrawal, or positive affect. Self-reported smoking satisfaction, enjoyment of respiratory tract sensations, psychological reward, craving reduction, and other rewarding effects of smoking were also significantly greater in the naturalistic smoking condition. Conclusions: The effects of using a ST device on the smoking experience should be considered when it is used in research as it may diminish some of the rewarding effects of smoking. Implications: When considering the inclusion of a smoking topography device in one’s research, it is important to know if use of that device will alter the smoker’s experience. This study assessed affective and subjective reactions to smoking through a topography device compared to naturalistic smoking. We found that smoking satisfaction, psychological reward, enjoyment of respiratory tract sensations and other rewarding effects were all diminished when smoking through the topography device. The effects of using a smoking topography device on the smoking experience should be considered when it is used in future research. PMID:26209851

  13. Reduced Exposure to Harmful and Potentially Harmful Smoke Constituents With the Tobacco Heating System 2.1.

    PubMed

    Lüdicke, Frank; Baker, Gizelle; Magnette, John; Picavet, Patrick; Weitkunat, Rolf

    2017-02-01

    Heating rather than burning tobacco reduces levels of harmful and potentially harmful constituents, and consumer products using this approach aim to reduce exposure to tobacco toxicants. The Tobacco Heating System (THS) version 2.1 has been enhanced from earlier prototypes with an improved heat control and sensorial experience and thereby user acceptance. Exposure measurements are required to determine whether it may be possible to reduce the individual health risk compared to smoking combustible cigarettes (CCs). This controlled clinical study randomly assigned 40 smokers to either a group continuing to use of their own CC brand (n = 20) or a group switching to THS 2.1 (n = 20) for 5 days. Biomarkers of exposure were measured at baseline and on day 1 through day 5. Product consumption, Human Puffing Topography, the occurrence of adverse events, and an assessment of subjective effects, such as smoking satisfaction and enjoyment of respiratory tract sensations, were also determined. The group of smokers who switched to THS 2.1 adapted their puffing behavior initially through longer puff duration and more puffs. During the duration of the study, total puff volume returned to baseline levels and the mean daily product consumption increased but with similar nicotine exposure compared to baseline CC use. Biomarkers of exposure to tobacco smoke toxicants which inform product risk assessment were significantly reduced with THS use compared to the CC group. THS 2.1 users experienced less reinforcing effects with THS 2.1 than with their own cigarette brand. THS 2.1 is a promising alternative to smoking CCs. Notwithstanding possible use adaption through consumption or puffing behavior, the exposure to harmful smoke constituents was markedly reduced with the new heated tobacco platform. Exposure markers to harmful and potentially harmful smoke constituents were lowered with the THS 2.1. Heating tobacco instead of burning can offer a potentially lower risk of delivering nicotine compared to CCs. © The Author 2016. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco.

  14. Response to Albuterol MDI Delivered Through an Anti-Static Chamber During Nocturnal Bronchospasm

    PubMed Central

    Prabhakaran, Sreekala; Shuster, Jonathan; Chesrown, Sarah; Hendeles, Leslie

    2013-01-01

    BACKGROUND Decreasing electrostatic charge on valved holding chambers increases the amount of drug delivered. However, there are no data demonstrating that this increases bronchodilatation. OBJECTIVE To investigate the influence of reducing electrostatic charge on the bronchodilator response to albuterol inhaler during nocturnal bronchospasm. METHODS This randomized double-blind, double-dummy crossover study included subjects, 18—40 years old, with nocturnal bronchospasm (20% overnight decrease in peak flow on 3 of 7 nights during run-in), FEV1 60–80% predicted during the day, and ≥ 12% increase after albuterol. Subjects slept in the clinical research center up to 3 nights for each treatment. FEV1 and heart rate were measured upon awakening spontaneously or at 4:00 am, and 15 min after each dose of 1, 2, and 4 cumulative puffs of albuterol via metered-dose inhaler. The drug was administered through an anti-static valved holding chamber (AeroChamber Plus Z-Stat) or a conventional valved holding chamber containing a static charge (AeroChamber Plus). RESULTS Of 88 consented subjects, 11 were randomized and 7 completed the study. Most exclusions were due to lack of objective evidence of nocturnal bronchospasm. Upon awakening, FEV1 was 44 ± 9% of predicted before the anti-static chamber and 48 ± 7% of predicted before the static chamber. The mean ± SD percent increase in FEV1 after 1, 2, and 4 cumulative puffs using the anti-static versus the static chamber, respectively, were 52 ± 26% versus 30 ± 19%, 73 ± 28% versus 48 ± 26%, and 90 ± 34% versus 64 ± 35%. The point estimates for the differences (and 95% CIs) between the devices (anti-static vs static) were 21% (4–38%) (P = .03), 23% (6–41%) (P = .02), and 25% (7–42%) (P = .01) for 1, 2, and 4 cumulative puffs, respectively. There was no significant difference in heart rate between treatments. CONCLUSIONS Delivery of albuterol through an anti-static chamber provides a clinically relevant improvement in bronchodilator response during acute, reversible bronchospasm such as nocturnal bronchospasm. PMID:22348270

  15. Bulbar conjunctival microvascular responses in dry eye

    PubMed Central

    Chen, Wan; Batawi, Hatim Ismail M.; Alava, Jimmy R.; Galor, Anat; Yuan, Jin; Sarantopoulos, Constantine D.; McClellan, Allison L.; Feuer, William J.; Levitt, Roy C.; Wang, Jianhua

    2017-01-01

    Purpose Conjunctival microvascular responses may be a surrogate metric of efferent neural pathway function innervating the ocular surface as changes in blood flow occur within seconds after a stimulus. As somatosensory dysfunction may partially underlie dry eye (DE), in this study we evaluate whether bulbar conjunctival microvascular alterations correlate with various aspects of DE. Methods Fifty-six DE patients were prospectively recruited from a Veterans Affairs ophthalmology clinic over an 11-month period. DE symptoms and ocular pain were assessed along with DE signs. A novel functional slit lamp biomicroscope (FSLB) was used to image the temporal bulbar conjunctiva from the right eye before and after central corneal stimulation with an air puff. Blood flow velocities were measured and noninvasive microvascular perfusion maps (nMPMs) were created. Results The bulbar blood flow velocity was 0.50±0.15 mm/s at baseline and increased to 0.55±0.17 mm/s after stimulation (P<0.001); the average change in velocity was 0.05±0.09. nMPMs values and venule diameter, on the other hand, did not significantly increase after stimulation (1.64±0.004 at baseline, 1.65±0.04 after stimulation, P=0.22 and 22.13±1.84 m at baseline, 22.21±2.04 μm after stimulation, P=0.73, respectively). Baseline blood flow velocity positively associated with Schirmer scores (r=0.40, P=0.002). Those with higher self-rated wind hyperalgesia demonstrated less change in blood flow velocity (r= −0.268, P=0.046) after air stimulation on the central cornea. Conclusion Conjunctival blood flow velocity, but not vessel diameter or complexity, increases after wind stimuli. Baseline flow positively correlated with Schirmer scores while change in flow negatively correlated with self-reported wind hyperalgesia. PMID:28042094

  16. Sensory neuropeptides modulate cigarette smoke-induced decrease in neutral endopeptidase activity in guinea pig airways.

    PubMed

    Kuo, H P; Lu, L C

    1995-01-01

    Cigarette smoke (CS) inhalation stimulates C-fibers to release sensory neuropeptides which mediate airway reflex responses to prevent irritants from entering the lower airways. When CS is inhaled via the upper airways, these airway defense responses may modulate the effect of CS on airway NEP activity and related airway hyperresponsiveness. To examine this possibility, we exposed guinea pigs to 1:10 diluted mid-tar cigarette smoke 100 puffs per day for 7 days and recorded pulmonary resistance of cumulative doses of neurokinin A (NKA, 10(-12)-10(-8) mol/kg, i.v.) or methacholine (Mch, 1-50 micrograms/kg, i.v.). NEP activity in the tracheobronchi was measured using fluorometric assay. Exposure of CS alone failed to alter the dose-response to NKA or Mch compared with air control. NEP activity in the airways after CS exposure was slightly but significantly lower than that of air control. Capsaicin pretreatment 1 week before CS exposure significantly shifted the dose-response curves of NKA, but not Mch, to the left and decreased NEP activity in the airways to a greater extent compared with CS exposure alone group. Capsaicin pretreatment alone failed to alter the responsiveness to NKA or NEP activity. CS also induced a significant increase in neutrophil counts in airways. Capsaicin pretreatment enhanced the effect of CS on neutrophil recruitment. We conclude that sensory neuropeptides may have a protective role in modulation of airways NEP activity downregulation induced by CS, probably by preventing CS from entering the lower airways or the chronic release of sensory neuropeptides induced by CS providing increased amount of substrata for NEP upregulation, and therefore modify the direct effect of CS on NEP activity and related airway hyperresponsiveness.

  17. An End-to-End Model of Plant Pheromone Channel for Long Range Molecular Communication.

    PubMed

    Unluturk, Bige D; Akyildiz, Ian F

    2017-01-01

    A new track in molecular communication is using pheromones which can scale up the range of diffusion-based communication from μm meters to meters and enable new applications requiring long range. Pheromone communication is the emission of molecules in the air which trigger behavioral or physiological responses in receiving organisms. The objective of this paper is to introduce a new end-to-end model which incorporates pheromone behavior with communication theory for plants. The proposed model includes both the transmission and reception processes as well as the propagation channel. The transmission process is the emission of pheromones from the leaves of plants. The dispersion of pheromones by the flow of wind constitutes the propagation process. The reception process is the sensing of pheromones by the pheromone receptors of plants. The major difference of pheromone communication from other molecular communication techniques is the dispersion channel acting under the laws of turbulent diffusion. In this paper, the pheromone channel is modeled as a Gaussian puff, i.e., a cloud of pheromone released instantaneously from the source whose dispersion follows a Gaussian distribution. Numerical results on the performance of the overall end-to-end pheromone channel in terms of normalized gain and delay are provided.

  18. Mapping multisensory parietal face and body areas in humans.

    PubMed

    Huang, Ruey-Song; Chen, Ching-fu; Tran, Alyssa T; Holstein, Katie L; Sereno, Martin I

    2012-10-30

    Detection and avoidance of impending obstacles is crucial to preventing head and body injuries in daily life. To safely avoid obstacles, locations of objects approaching the body surface are usually detected via the visual system and then used by the motor system to guide defensive movements. Mediating between visual input and motor output, the posterior parietal cortex plays an important role in integrating multisensory information in peripersonal space. We used functional MRI to map parietal areas that see and feel multisensory stimuli near or on the face and body. Tactile experiments using full-body air-puff stimulation suits revealed somatotopic areas of the face and multiple body parts forming a higher-level homunculus in the superior posterior parietal cortex. Visual experiments using wide-field looming stimuli revealed retinotopic maps that overlap with the parietal face and body areas in the postcentral sulcus at the most anterior border of the dorsal visual pathway. Starting at the parietal face area and moving medially and posteriorly into the lower-body areas, the median of visual polar-angle representations in these somatotopic areas gradually shifts from near the horizontal meridian into the lower visual field. These results suggest the parietal face and body areas fuse multisensory information in peripersonal space to guard an individual from head to toe.

  19. Evoking Blinks with Natural Stimulation and Detecting Them with a Noninvasive Optical Device: A Simple, Inexpensive Method for Use with Freely Moving Animals

    PubMed Central

    Weiss, Craig; Disterhoft, John F.

    2008-01-01

    Many laboratories studying eyeblinks in unanesthetized rodents use a periorbital shock to evoke the blink. The stimulus is typically delivered via a tether and usually obliterates detection of a full unconditioned response with electromyographic (EMG) recording. Here we describe the adapter we have used successfully for several years to deliver puffs of air to the cornea of freely moving rats during our studies of eyeblink conditioning. The stimulus evokes an unconditioned response that can be recorded without affecting the EMG signal. This allows a complete analysis of the unconditioned response which is important for studies examining reflex modification or the effect of drugs, genetic manipulations, or aging on the unconditioned blink reflex. We also describe an infrared reflective sensor that can be added to the tether to minimize the number of wires that need to be implanted around the eye, and which is relatively immune to electrical artifacts associated with a periorbital shock stimulus or other devices powered by alternating current. The responses recorded simultaneously by EMG wires and the optical sensor appear highly correlated and demonstrate that the optical sensor can measure responses that might otherwise be lost due to electrical interference from a shock stimulus. PMID:18598716

  20. Eye-blink conditioning deficits indicate temporal processing abnormalities in schizophrenia.

    PubMed

    Bolbecker, Amanda R; Mehta, Crystal S; Edwards, Chad R; Steinmetz, Joseph E; O'Donnell, Brian F; Hetrick, William P

    2009-06-01

    Theoretical models suggest that symptoms of schizophrenia may be due to a dysfunctional modulatory system associated with the cerebellum. Although it has long been known that the cerebellum plays a critical role in associative learning and motor timing, recent evidence suggests that it also plays a role in nonmotor psychological processes. Indeed, cerebellar anomalies in schizophrenia have been linked to cognitive dysfunction and poor long-term outcome. To test the hypothesis that schizophrenia is associated with cerebellar dysfunction, cerebellar-dependent, delay eye-blink conditioning was examined in 62 individuals with schizophrenia and 62 age-matched non-psychiatric comparison subjects. The conditioned stimulus was a 400 ms tone, which co-terminated with a 50 ms unconditioned stimulus air puff. A subset of participants (25 with schizophrenia and 29 controls) also completed the Wechsler Abbreviated Scale of Intelligence. Participants with schizophrenia exhibited lower rates of eye-blink conditioning, including earlier (less adaptively timed) conditioned response latencies. Cognitive functioning was correlated with the rate of conditioned responsing in the non-psychiatric comparison subjects but not among those with schizophrenia, and the magnitude of these correlations significantly differed between groups. These findings are consistent with models of schizophrenia in which disruptions within the cortico-cerebellar-thalamic-cortical (CCTC) brain circuit are postulated to underlie the cognitive fragmentation that characterizes the disorder.

  1. Eye-Blink Conditioning Deficits Indicate Temporal Processing Abnormalities in Schizophrenia

    PubMed Central

    Bolbecker, Amanda R.; Mehta, Crystal; Edwards, Chad R.; Steinmetz, Joseph E.; O’Donnell, Brian F.; Hetrick, William P.

    2009-01-01

    Theoretical models suggest that symptoms of schizophrenia may be due to a dysfunctional modulatory system associated with the cerebellum. Although it has long been known that the cerebellum plays a critical role in associative learning and motor timing, recent evidence suggests that it also plays a role in nonmotor psychological processes. Indeed, cerebellar anomalies in schizophrenia have been linked to cognitive dysfunction and poor long-term outcome. To test the hypothesis that schizophrenia is associated with cerebellar dysfunction, cerebellar-dependent, delay eye-blink conditioning was examined in 62 individuals with schizophrenia and 62 age-matched non-psychiatric comparison subjects. The conditioned stimulus was a 400 ms tone, which co-terminated with a 50 ms unconditioned stimulus air puff. A subset of participants (25 with schizophrenia and 29 controls) also completed the Wechsler Abbreviated Scale of Intelligence. Participants with schizophrenia exhibited lower rates of eye-blink conditioning, including earlier (less adaptively timed) conditioned response latencies. Cognitive functioning was correlated with the rate of conditioned responsing in the non-psychiatric comparison subjects but not among those with schizophrenia, and the magnitude of these correlations significantly differed between groups. These findings are consistent with models of schizophrenia in which disruptions within the cortico-cerebellar-thalamic-cortical (CCTC) brain circuit are postulated to underlie the cognitive fragmentation that characterizes the disorder. PMID:19351577

  2. The contribution of megacities to regional sulfur pollution in Asia

    NASA Astrophysics Data System (ADS)

    Guttikunda, Sarath K.; Carmichael, Gregory R.; Calori, Giuseppe; Eck, Christina; Woo, Jung-Hun

    Asia is undergoing rapid urbanization resulting in increasing air pollution threats in its cities. The contribution of megacities to sulfur emissions and pollution in Asia is studied over a 25-year period (1975-2000) using a multi-layer Lagrangian puff transport model. Asian megacities cover <2% of the land area but emit ˜16% of the total anthropogenic sulfur emissions of Asia. It is shown that urban sulfur emissions contribute over 30% to the regional pollution levels in large parts of Asia. The average contribution of megacities over the western Pacific increased from <5% in 1975 to >10% in 2000. Two future emission scenarios are evaluated for 2020—"business as usual (BAU)" and "maximum feasible controls (MAXF)" to establish the range of reductions possible for these cities. The MAXF scenario would result in 2020 S-emissions that are ˜80% lower than those in 2000, at an estimated control cost of US 87 billion per year (1995 US) for all of Asia. An urban scale analysis of sulfur pollution for four megacities—Shanghai, and Chongqing in China; Seoul in South Korea; and Mumbai (formerly Bombay) in India is presented. If pollution levels were allowed to increase under BAU, over 30 million people in these cities alone would be exposed to levels in excess of the WHO guidelines.

  3. Granger causal time-dependent source connectivity in the somatosensory network

    NASA Astrophysics Data System (ADS)

    Gao, Lin; Sommerlade, Linda; Coffman, Brian; Zhang, Tongsheng; Stephen, Julia M.; Li, Dichen; Wang, Jue; Grebogi, Celso; Schelter, Bjoern

    2015-05-01

    Exploration of transient Granger causal interactions in neural sources of electrophysiological activities provides deeper insights into brain information processing mechanisms. However, the underlying neural patterns are confounded by time-dependent dynamics, non-stationarity and observational noise contamination. Here we investigate transient Granger causal interactions using source time-series of somatosensory evoked magnetoencephalographic (MEG) elicited by air puff stimulation of right index finger and recorded using 306-channel MEG from 21 healthy subjects. A new time-varying connectivity approach, combining renormalised partial directed coherence with state space modelling, is employed to estimate fast changing information flow among the sources. Source analysis confirmed that somatosensory evoked MEG was mainly generated from the contralateral primary somatosensory cortex (SI) and bilateral secondary somatosensory cortices (SII). Transient Granger causality shows a serial processing of somatosensory information, 1) from contralateral SI to contralateral SII, 2) from contralateral SI to ipsilateral SII, 3) from contralateral SII to contralateral SI, and 4) from contralateral SII to ipsilateral SII. These results are consistent with established anatomical connectivity between somatosensory regions and previous source modeling results, thereby providing empirical validation of the time-varying connectivity analysis. We argue that the suggested approach provides novel information regarding transient cortical dynamic connectivity, which previous approaches could not assess.

  4. High Throughput Determination of Mercury in Tobacco and Mainstream Smoke from Little Cigars

    PubMed Central

    Fresquez, Mark R.; Gonzalez-Jimenez, Nathalie; Gray, Naudia; Watson, Clifford H.; Pappas, R. Steven

    2015-01-01

    A method was developed that utilizes a platinum trap for mercury from mainstream tobacco smoke which represents an improvement over traditional approaches that require impingers and long sample preparation procedures. In this approach, the trapped mercury is directly released for analysis by heating the trap in a direct mercury analyzer. The method was applied to the analysis of mercury in the mainstream smoke of little cigars. The mercury levels in little cigar smoke obtained under Health Canada Intense smoking machine conditions ranged from 7.1 × 10−3 mg/m3 to 1.2 × 10−2 mg/m3. These air mercury levels exceed the chronic inhalation Minimal Risk Level corrected for intermittent exposure to metallic mercury (e.g., 1 or 2 hours per day, 5 days per week) determined by the Agency for Toxic Substances and Disease Registry. Multivariate statistical analysis was used to assess associations between mercury levels and little cigar physical design properties. Filter ventilation was identified as the principal physical parameter influencing mercury concentrations in mainstream little cigar smoke generated under ISO machine smoking conditions. With filter ventilation blocked under Health Canada Intense smoking conditions, mercury concentrations in tobacco and puff number (smoke volume) were the primary physical parameters that influenced mainstream smoke mercury concentrations. PMID:26051388

  5. Flow-mediated dilation and peripheral arterial tonometry are disturbed in preeclampsia and reflect different aspects of endothelial function.

    PubMed

    Mannaerts, Dominique; Faes, Ellen; Goovaerts, Inge; Stoop, Tibor; Cornette, Jerome; Gyselaers, Wilfried; Spaanderman, Marc; Van Craenenbroeck, Emeline M; Jacquemyn, Yves

    2017-11-01

    Endothelial function and arterial stiffness are known to be altered in preeclamptic pregnancies. Previous studies have shown conflicting results regarding the best technique for assessing vascular function in pregnancy. In this study, we made a comprehensive evaluation of in vivo vascular function [including flow-mediated dilatation (FMD), peripheral arterial tonometry (PAT), and arterial stiffness] in preeclamptic patients and compared them with normal pregnancies. In addition, we assessed the relation between vascular function and systemic inflammation. Fourteen patients with preeclampsia (PE) and 14 healthy pregnant controls were included. Endothelial function was determined by FMD and PAT and arterial stiffness by carotid-femoral pulse-wave velocity and augmentation index. Systemic inflammation was assessed using mean platelet volume (MPV) and neutrophil-lymphocyte ratio (NLR). The reactive hyperemia index, assessed using PAT, is decreased at the third trimester compared with the first trimester in a normal, uncomplicated pregnancy ( P = 0.001). Arterial stiffness is significantly higher in PE versus normal pregnancy ( P < 0.001). Endothelial function, obtained by FMD, is deteriorated in PE versus normal pregnancy ( P = 0.015), whereas endothelial function assessment by PAT is improved in PE versus normal pregnancy ( P = 0.001). Systemic inflammation (MPV and NLR) increases during normal pregnancy. FMD and PAT are disturbed in PE. Endothelial function, assessed by FMD and PAT, shows distinct results. This may indicate that measurements with FMD and PAT reflect different aspects of endothelial function and that PAT should not be used as a substitute for FMD as a measure of endothelial function in pregnancy. Copyright © 2017 the American Physiological Society.

  6. Relation between digital peripheral arterial tonometry and brachial artery ultrasound measures of vascular function in patients with coronary artery disease and in healthy volunteers.

    PubMed

    Lee, Craig R; Bass, Almasa; Ellis, Kyle; Tran, Bryant; Steele, Savanna; Caughey, Melissa; Stouffer, George A; Hinderliter, Alan L

    2012-03-01

    Digital peripheral arterial tonometry (PAT) is an emerging, noninvasive method to assess vascular function. The physiology underlying this phenotype, however, remains unclear. Therefore, we evaluated the relation between digital PAT and established brachial artery ultrasound measures of vascular function under basal conditions and after reactive hyperemia. Using a cross-sectional study design, digital PAT and brachial artery ultrasonography with pulsed wave Doppler were simultaneously completed at baseline and after reactive hyperemia in both those with established coronary artery disease (n = 99) and healthy volunteers with low cardiovascular disease risk (n = 40). Under basal conditions, the digital pulse volume amplitude demonstrated a significant positive correlation with the brachial artery velocity-time integral that was independent of the arterial diameter, in both the healthy volunteer (r(s) = 0.64, p <0.001) and coronary artery disease (r(s) = 0.63, p <0.001) cohorts. Similar positive relations were observed with the baseline brachial artery blood flow velocity and blood flow. In contrast, no relation between the reactive hyperemia-evoked digital PAT ratio and either brachial artery flow-mediated dilation or shear stress was observed in either cohort (p = NS). In conclusion, these findings demonstrate that the digital PAT measures of vascular function more closely reflect basal blood flow in the brachial artery than reactive hyperemia-induced changes in the arterial diameter or flow velocity, and the presence of vascular disease does not modify the physiology underlying the digital PAT phenotype. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Ophthalmic examination of the captive western lowland gorilla (Gorilla gorilla gorilla).

    PubMed

    Liang, David; Alvarado, Thomas P; Oral, Deniz; Vargas, Jose M; Denena, Melissa M; McCulley, James P

    2005-09-01

    This study examined the captive western lowland gorilla (Gorilla gorilla gorilla) eye as compared and contrasted with the human eye. Bilateral ophthalmic examinations of western lowland gorillas (n = 5) while under general anesthesia were performed opportunistically, including slit-lamp biomicroscopy, dilated fundus examination, cycloplegic retinoscopy, Schiotz tonometry, corneal diameter and thickness measurements, A-scan and B-scan ultrasonography, keratometry, and cultures of the eyelid margins and bulbar conjunctiva. Mean spherical equivalent refractive error by cycloplegic retinoscopy was +1.20 +/- 0.59 diopters. Mean intraocular pressure by Schiotz tonometry was 12.0 +/- 4.3 mm Hg. Mean optic nerve head cup to disc ratio was 0.42 +/- 0.11. Mean horizontal corneal diameter was 13.4 +/- 0.8 mm, and mean vertical cornea diameter was 12.7 +/- 0.8 mm. Mean central corneal thickness by ultrasound pachymetry was 489 +/- 52 microm. Mean axial length of the eye by A-scan was 22.75 +/- 0.71 mm. Mean lens thickness by A-scan was 4.23 +/- 0.34 mm. Mean anterior chamber depth by A-scan was 4.00 +/- 0.26 mm. Mean keratometry reading was 44.38 +/- 1.64 diopters. Eyelid margin and bulbar conjunctival cultures isolated Candida sp. (n = 5), Staphylococcus aureus (n = 4), Staphylococcus epidermidis (n = 3), Staphylococcus saccharolyticus (n = 3), and Micrococcus sp. (n = 3). This study suggests important similarities between western lowland gorilla and human eyes. These similarities may allow diagnostics, techniques, and equipment for human eye surgery, such as those used for cataract extraction and intraocular lens implantation, to be successfully utilized for gorillas.

  8. A Cross-Sectional Study of the Cardiovascular Effects of Welding Fumes.

    PubMed

    Li, Huiqi; Hedmer, Maria; Kåredal, Monica; Björk, Jonas; Stockfelt, Leo; Tinnerberg, Håkan; Albin, Maria; Broberg, Karin

    2015-01-01

    Occupational exposure to particulate air pollution has been associated with an increased risk of cardiovascular disease. However, the risk to welders working today remains unclear. We aimed to elucidate the cardiovascular effects of exposure to welding fumes. In a cross-sectional study, structured interviews and biological sampling were conducted for 101 welders and 127 controls (all non-smoking males) from southern Sweden. Personal breathing zone sampling of respirable dust was performed. Blood pressure (BP) and endothelial function (using peripheral arterial tonometry) were measured. Plasma and serum samples were collected from peripheral blood for measurement of C-reactive protein, low-density lipoprotein, homocysteine, serum amyloid A, and cytokines. Welders were exposed to 10-fold higher levels of particles than controls. Welders had significantly higher BP compared to controls, an average of 5 mm Hg higher systolic and diastolic BP (P ≤ 0.001). IL-8 was 3.4 ng/L higher in welders (P=0.010). Years working as a welder were significantly associated with increased BP (β=0.35, 95%CI 0.13 - 0.58, P=0.0024 for systolic BP; β=0.32, 95%CI 0.16 - 0.48, P<0.001 for diastolic BP, adjusted for BMI) but exposure to respirable dust was not associated with BP. No clear associations occurred between welding and endothelial function, or other effect markers. A modest increase in BP was found among welders compared to controls suggesting that low-to-moderate exposure to welding fumes remains a risk factor for cardiovascular disease.

  9. Thermal Ignition

    NASA Astrophysics Data System (ADS)

    Boettcher, Philipp Andreas

    Accidental ignition of flammable gases is a critical safety concern in many industrial applications. Particularly in the aviation industry, the main areas of concern on an aircraft are the fuel tank and adjoining regions, where spilled fuel has a high likelihood of creating a flammable mixture. To this end, a fundamental understanding of the ignition phenomenon is necessary in order to develop more accurate test methods and standards as a means of designing safer air vehicles. The focus of this work is thermal ignition, particularly auto-ignition with emphasis on the effect of heating rate, hot surface ignition and flame propagation, and puffing flames. Combustion of hydrocarbon fuels is traditionally separated into slow reaction, cool flame, and ignition regimes based on pressure and temperature. Standard tests, such as the ASTM E659, are used to determine the lowest temperature required to ignite a specific fuel mixed with air at atmospheric pressure. It is expected that the initial pressure and the rate at which the mixture is heated also influences the limiting temperature and the type of combustion. This study investigates the effect of heating rate, between 4 and 15 K/min, and initial pressure, in the range of 25 to 100 kPa, on ignition of n-hexane air mixtures. Mixtures with equivalence ratio ranging from 0.6 to 1.2 were investigated. The problem is also modeled computationally using an extension of Semenov's classical auto-ignition theory with a detailed chemical mechanism. Experiments and simulations both show that in the same reactor either a slow reaction or an ignition event can take place depending on the heating rate. Analysis of the detailed chemistry demonstrates that a mixture which approaches the ignition region slowly undergoes a significant modification of its composition. This change in composition induces a progressive shift of the explosion limit until the mixture is no longer flammable. A mixture that approaches the ignition region sufficiently rapidly undergoes only a moderate amount of thermal decomposition and explodes quite violently. This behavior can also be captured and analyzed using a one-step reaction model, where the heat release is in competition with the depletion of reactants. Hot surface ignition is examined using a glow plug or heated nickel element in a series of premixed n-hexane air mixtures. High-speed schlieren photography, a thermocouple, and a fast response pressure transducer are used to record flame characteristics such as ignition temperature, flame speed, pressure rises, and combustion mode. The ignition event is captured by considering the dominant balance of diffusion and chemical reaction that occurs near a hot surface. Experiments and models show a dependence of ignition temperature on mixture composition, initial pressure, and hot surface size. The mixtures exhibit the known lower flammability limit where the maximum temperature of the hot surface was insufficient at igniting the mixture. Away from the lower flammability limit, the ignition temperature drops to an almost constant value over a wide range of equivalence ratios (0.7 to 2.8) with large variations as the upper flammability limit is approached. Variations in the initial pressure and equivalence ratio also give rise to different modes of combustion: single flame, re-ignition, and puffing flames. These results are successfully compared to computational results obtained using a flamelet model and a detailed chemical mechanism for n-heptane. These different regimes can be delineated by considering the competition between inertia, i.e., flame propagation, and buoyancy, which can be expressed in the Richardson number. In experiments of hot surface ignition and subsequent flame propagation a 10 Hz puffing flame instability is visible in mixtures that are stagnant and premixed prior to the ignition sequence. By varying the size of the hot surface, power input, and combustion vessel volume, we determined that the instability is a function of the interaction of the flame with the fluid flow induced by the combustion products rather than the initial plume established by the hot surface. The phenomenon is accurately reproduced in numerical simulations and a detailed flow field analysis revealed a competition between the inflow velocity at the base of the flame and the flame propagation speed. The increasing inflow velocity, which exceeds the flame propagation speed, is ultimately responsible for creating a puff. The puff is then accelerated upward, allowing for the creation of the subsequent instabilities. The frequency of the puffing is proportional to the gravitational acceleration and inversely proportional to the flame speed. We propose a relation describing the dependence of the frequency on gravitational acceleration, hot surface diameter, and flame speed. This relation shows good agreement for lean and rich n-hexane-air as well as lean hydrogen-air flames.

  10. Feeding Concept, Military Vs Civilian System

    DTIC Science & Technology

    1990-12-01

    Pudding d 3 c Chocolate Pudding w/Whipped Topping d 3 c Cowboy Cookies d 3 c Cream Puffs d 3 c Donuts d...c Fruit Won Tons d 3 c Gelatin Cubes d 3 c Hermits d 3 c Ice Box Cookies d : c Ice Cream d...I c Jelly Bar Spritz d 3 c Jelly Roll d : c Lemon Meringue Pie d : c Lime Gelatin Cubes d : c Oatmeal Cookies

  11. Phlebotomus Sandflies of the Paloich Area in the Sudan (Diptera, Psychodidae)

    DTIC Science & Technology

    1964-10-01

    Hamster, Cricetus auratus Toad, Bufo regularis (?) Gecko, H. turicus Skink, M. striata Puff adder Snake, CMNH HH-9111’ Snake, CMNH HH-9112’ Hedgehog ...Pharynx unarmed distally or only with few, smail spines ; pigment patch not dark enough to obscure teeth .................. 8 Pharynx heavily...armed distally with numerous, dark spines ; pigment patch very dark, 1964 Quate: Sudanese sandflies 237 often obscuring teeth unless specimen well

  12. Smoking Behavior and Exposure: Results of a Menthol Cigarette Cross-over Study.

    PubMed

    Watson, Christina Vaughan; Richter, Patricia; de Castro, B Rey; Sosnoff, Connie; Potts, Jennifer; Clark, Pamela; McCraw, Joan; Yan, Xizheng; Chambers, David; Watson, Clifford

    2017-05-01

    Our objective was to improve understanding of the differences in use behavior and exposure when smoking menthol and non-menthol cigarettes using a 2-part cross-over design. Adult daily smokers were assigned randomly to alternate between 2 weeks of exclusively smoking a menthol test cigarette or a non-menthol test cigarette. Urine and saliva were collected for biomarker measurements; carbon monoxide (CO) was measured, and participants smoked test cigarettes through a CreSS® smoking topography device during 3 clinic visits. Participants turned in their cigarette butts from the test periods for determination of mouth level nicotine and completed subjective questionnaires related to the test cigarettes. Regardless of cigarette preference, participants had higher salivary cotinine when smoking the non-menthol test cigarette, but there were no significant differences detected in urine 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol between the 2 test cigarettes. Mouth level nicotine, puff volume, and puff duration were significantly higher when smoking the menthol brand. Both menthol and non-menthol smokers reported significantly lower enjoyment and satisfaction scores for test cigarettes compared with their brand of choice. Our results suggest that mentholation has an effect on measures of smoking behavior and that mouth level nicotine is a useful indicator of between-brand smoke exposure.

  13. Study of the confinement properties in a reversed-field pinch with mode rotation and gas fuelling

    NASA Astrophysics Data System (ADS)

    Cecconello, M.; Malmberg, J.-A.; Nielsen, P.; Pasqualotto, R.; Drake, J. R.

    2002-08-01

    An extensive investigation of the global confinement properties in different operating scenarios in the rebuilt EXTRAP T2R reversed-field pinch (RFP) experiment is reported here. In particular, the role of a fast gas puff valve system, used to control plasma density, on confinement is studied. Without gas puffing, the electron density decays below 0.5×1019 m-3. The poloidal beta varies between 5% and 15%, decreasing at large I/N. The energy confinement time ranges from 70 to 225 μs. With gas puffing, the density is sustained at ne≈1.5×1019 m-3. However, a general slight deterioration of the plasma performances is observed for the same values of I/N: the plasma becomes cooler and more radiative. The poloidal beta is comparable to that in the scenarios without puff but the energy confinement time drops ranging from 60 to 130 μs. The fluctuation level and the energy confinement time have been found to scale with the Lundquist number as S-0.05+/-0.07 and S0.5+/-0.1, respectively. Mode rotation is typical for all the discharges and rotation velocity is observed to increase with increasing electron diamagnetic velocity.

  14. The linear relationship between cigarette tar and nicotine yields: regulatory implications for smoke constituent ratios.

    PubMed

    St Charles, F K; Cook, C J; Clayton, P M

    2011-02-01

    Cigarette smoke analyte yields are often expressed as ratios relative to tar or nicotine yields, usually to compare different products or to estimate human uptake of smoke in relation to nicotine uptake measurements. The method, however, can lead to distorted interpretations, especially in the case of ratios from ultra-low tar yield cigarettes. In brief, as tar yields decrease below the 5–6 mg per cigarette range, the tar-to-nicotine ratio (TNR) decreases rapidly in a non-linear fashion. If, however, the nicotine yield, rather than the ratio, is plotted versus the tar yield, the non-linearity disappears and a straight line is obtained, with a slight positive intercept for nicotine on the ordinate. Unlike the ratio, the slope appears to depend only on the concentration of the nicotine in the blend and does not appear to vary with smoking parameters such as puff volume, puff interval or length smoked or with cigarette design parameters such as length, circumference or the amount of filtration or filter ventilation. Therefore, such a slope is analogous to the TNR although, unlike that ratio, it is invariant. Even more simply, the concentration of the nicotine in the blend, at least for American blend-style cigarettes, provides a similar index.

  15. Shock formation in Ne, Ar, Kr, and Xe on deuterium gas puff implosions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narkis, J.; Rahman, H. U.; Ney, P.

    2016-12-29

    1- and 2-D simulations of 1-cm radius, gas-puff liners of Ne, Ar, Kr, and Xe imploding onto a deuterium target are conducted using the discharge parameters for the Zebra (1 MA, 130 ns) driver using the resistive MHD code MACH2. This is an implementation of the Staged Z-pinch concept, in which the target is driven to high-energy-density first by shock compression launched by a diffused azimuthal magnetic field (J×B force), and then by the adiabatic compression as the liner converges on axis. During the run-in phase, the initial shock heating preheats the deuterium plasma, with a subsequent stable, adiabatic compressionmore » heating the target to high energy density. Shock compression of the target coincides with the development of a J×B force at the target/liner interface. Stronger B-field transport and earlier shock compression increases with higher-Z liners, which results in an earlier shock arrival on axis. As a result, delayed shock formation in lower-Z liners yields a relative increase in shock heating, however, the 2-D simulations show an increased target isolation from magneto-Rayleigh-Taylor instability penetration, suggesting that an optimal balance between these two effects is reached in an Ar or Kr liner, rather than with Xe.« less

  16. Dual Use of Cigarettes, Little Cigars, Cigarillos, and Large Cigars: Smoking Topography and Toxicant Exposure

    PubMed Central

    Pickworth, Wallace B.; Rosenberry, Zachary R.; O’Grady, Kevin E.; Koszowski, Bartosz

    2017-01-01

    Objective Smoking topography variables and toxicant exposure (plasma nicotine and exhaled CO) were examined in 3 groups of study participants that smoked both cigarettes and either filtered little cigars (Winchester), cigarillos (Black & Mild), or large cigars (Phillies Blunt). Methods Laboratory ad lib smoking of the cigar products was collected with a smoking puff analyzer; plasma levels of nicotine and exhaled CO were collected before and after smoking. Results Although there were no statistically significant differences in demographic and cigarette smoking topography among the groups, there were significant differences in how the different cigar products were smoked. Plasma nicotine boost was similar after all products but exhaled CO was greater after the cigarillo and large cigar than the little cigar. Some of the differences were due to the differences in article size but other differences were apparent even after adjustment for the amount of tobacco burned or the mouth intake (puff volume). Conclusions The topography findings of differences among products challenge the practice of grouping cigars as a single entity in surveys, regulatory decisions, and discussions of toxicant exposure. The results add to the discussion of distinctions among products in the scientific assessment of public health risk and regulatory decisions. PMID:28966952

  17. Smoking topography and abstinence in adult female smokers.

    PubMed

    McClure, Erin A; Saladin, Michael E; Baker, Nathaniel L; Carpenter, Matthew J; Gray, Kevin M

    2013-12-01

    Preliminary evidence, within both adults and adolescents, suggests that the intensity with which cigarettes are smoked (i.e., smoking topography) is predictive of success during a cessation attempt. These reports have also shown topography to be superior compared to other variables, such as cigarettes per day, in the prediction of abstinence. The possibility that gender may influence this predictive relationship has not been evaluated but may be clinically useful in tailoring gender-specific interventions. Within the context of a clinical trial for smoking cessation among women, adult daily smokers completed a laboratory session that included a 1-hour ad libitum smoking period in which measures of topography were collected (N=135). Participants were then randomized to active medication (nicotine patch vs. varenicline) and abstinence was monitored for 4weeks. Among all smoking topography measures and all abstinence outcomes, a moderate association was found between longer puff duration and greater puff volume and continued smoking during the active 4-week treatment phase, but only within the nicotine patch group. Based on the weak topography-abstinence relationship among female smokers found in the current study, future studies should focus on explicit gender comparisons to examine if these associations are specific to or more robust in male smokers. © 2013 Elsevier Ltd. All rights reserved.

  18. Intermittent fluctuations in the Alcator C-Mod scrape-off layer for ohmic and high confinement mode plasmas

    NASA Astrophysics Data System (ADS)

    Garcia, O. E.; Kube, R.; Theodorsen, A.; LaBombard, B.; Terry, J. L.

    2018-05-01

    Plasma fluctuations in the scrape-off layer of the Alcator C-Mod tokamak in ohmic and high confinement modes have been analyzed using gas puff imaging data. In all cases investigated, the time series of emission from a single spatially resolved view into the gas puff are dominated by large-amplitude bursts, attributed to blob-like filament structures moving radially outwards and poloidally. There is a remarkable similarity of the fluctuation statistics in ohmic plasmas and in edge localized mode-free and enhanced D-alpha high confinement mode plasmas. Conditionally averaged waveforms have a two-sided exponential shape with comparable temporal scales and asymmetry, while the burst amplitudes and the waiting times between them are exponentially distributed. The probability density functions and the frequency power spectral densities are similar for all these confinement modes. These results provide strong evidence in support of a stochastic model describing the plasma fluctuations in the scrape-off layer as a super-position of uncorrelated exponential pulses. Predictions of this model are in excellent agreement with experimental measurements in both ohmic and high confinement mode plasmas. The stochastic model thus provides a valuable tool for predicting fluctuation-induced plasma-wall interactions in magnetically confined fusion plasmas.

  19. Genetic and Molecular Analysis of the X Chromosomal Region 14b17-14c4 in Drosophila Melanogaster: Loss of Function in Nona, a Nuclear Protein Common to Many Cell Types, Results in Specific Physiological and Behavioral Defects

    PubMed Central

    Stanewsky, R.; Rendahl, K. G.; Dill, M.; Saumweber, H.

    1993-01-01

    We have performed a genetic analysis of the 14C region of the X chromosome of Drosophila melanogaster to isolate loss of function alleles of no-on-transient A (nonA; 14C1-2; 1-52.3). NONA is a nuclear protein common to many cell types, which is present in many puffs on polytene chromosomes. Sequence data suggest that the protein contains a pair of RNA binding motifs (RRM) found in many single-strand nucleic acid binding proteins. Hypomorphic alleles of this gene, which lead to aberrant visual and courtship song behavior, still contain normally distributed nonA RNA and NONA protein in embryos, and in all available alleles NONA protein is present in puffs of third instar larval polytene chromosomes. We find that complete loss of this general nuclear protein is semilethal in hemizygous males and homozygous cell lethal in the female germline. Surviving males show more extreme defects in nervous system function than have been described for the hypomorphic alleles. Five other essential genes that reside within this region have been partially characterized. PMID:8244005

  20. Diagnostics of deuterium gas-puff z-pinch experiments on the GIT-12 generator

    NASA Astrophysics Data System (ADS)

    Cikhardt, J.; Klir, D.; Rezac, K.; Kubes, P.; Kravarik, J.; Batobolotova, B.; Sila, O.; Turek, K.; Shishlov, A.; Labetsky, A.; Kokshenev, V.; Chedizov, R.; Ratakhin, N.; Varlachev, V.; Garapatsky, A.; Dudkin, G.; Padalko, V.; GIT-12 Team

    2014-10-01

    Z-pinch experiments with a deuterium gas-puff and an outer plasma shell generated by plasma guns were carried out on the GIT-12 generator at the IHCE in Tomsk. Using this novel configuration of the load, the neutron yields from the DD reaction were significantly increased from 2×1011 up to 3×1012 neutrons per shot at the current level of about 3 MA. In addition to recent experiments, the threshold activation detectors were used in order to get the information about the energy spectrum of the generated neutrons. The copper, indium, and lead samples were irradiated by the pulse of the neutrons generated during the experimental shot. The decay radiation of the products from the reactions 63Cu(n,2n)62Cu, 115In(n, γ) 116 mIn and 206Pb (n,3n)204mPb was observed using gamma spectrometer. According to the used neutron ToF scintillation detectors, the energy of neutrons reaches up to 20 MeV. The work was supported by the MSMT of the Czech Republic research Programs No. ME090871, No. LG13029, by the GACR Grant No. P205/12/0454, Grant CRA IAEA No. 17088 and RFBR research Project No. 13-08-00479-a.

Top