Science.gov

Sample records for air cleaner efficiency

  1. FRACTIONAL AEROSOL FILTRATION EFFICIENCY OF IN-DUCT VENTILATION AIR CLEANERS

    EPA Science Inventory

    The filtration efficiency of ventilation air cleaners is highly particle-size dependent over the 0.01 to 3 μm diameter size range. Current standardized test methods, which determine only overall efficiencies for ambient aerosol or other test aerosols, provide data of limited util...

  2. Environmental Technology Verification: Supplement to Test/QA Plan for Biological and Aerosol Testing of General Ventilation Air Cleaners; Bioaerosol Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Air Cleaners

    EPA Science Inventory

    The Air Pollution Control Technology Verification Center has selected general ventilation air cleaners as a technology area. The Generic Verification Protocol for Biological and Aerosol Testing of General Ventilation Air Cleaners is on the Environmental Technology Verification we...

  3. Cleaner, More Efficient Diesel Engines

    SciTech Connect

    Musculus, Mark

    2013-08-13

    Mark Musculus, an engine combustion scientist at Sandia National Laboratories, led a study that outlines the science base for auto and engine manufacturers to build the next generation of cleaner, more efficient engines using low-temperature combustion. Here, Musculus discusses the work at Sandia's Combustion Research Facility.

  4. Cleaner, More Efficient Diesel Engines

    ScienceCinema

    Musculus, Mark

    2016-07-12

    Mark Musculus, an engine combustion scientist at Sandia National Laboratories, led a study that outlines the science base for auto and engine manufacturers to build the next generation of cleaner, more efficient engines using low-temperature combustion. Here, Musculus discusses the work at Sandia's Combustion Research Facility.

  5. Mold occurring on the air cleaner high-efficiency particulate air filters used in the houses of child patients with atopic dermatitis.

    PubMed

    Kim, Seong Hwan; Ahn, Geum Ran; Son, Seung Yeol; Bae, Gwi-Nam; Yun, Yeo Hong

    2014-09-01

    Fungi are the known sources of irritation associated with atopic diseases (e.g., asthma, allergic rhinoconjunctivitis, and atopic eczema). To quantitatively estimate their presence in the indoor environment of atopic dermatitis-inflicted child patient's houses (ADCPHs), the high-efficiency particulate air (HEPA) filters installed inside the air cleaners of three different ADCPHs were investigated for the presence of mold. The air cleaner HEPA filters obtained from the three different ADCPHs were coded as HEPA-A, -B, and -C, respectively, and tested for the presence of mold. The colony forming units (CFUs) corresponding to the HEPA-A, -B, and -C filters were estimated to be 6.51 × 10(2) ± 1.50 × 10(2) CFU/cm(2), 8.72 × 10(2) ± 1.69 × 10(2) CFU/cm(2), and 9.71 × 10(2) ± 1.35 × 10(2) CFU/cm(2), respectively. Aspergillus, Penicillium, Alternaria, Cladosporium, Trichoderma, and other fungal groups were detected in the 2,494 isolates. The distribution of these fungal groups differed among the three filters. Cladosporium was the major fungal group in filters HEPA-A and -C, whereas Penicillium was the major fungal group in the filter HEPA-B. Nine fungal species, including some of the known allergenic species, were identified in these isolates. Cladosporium cladosporioides was the most common mold among all the three filters. This is the first report on the presence of fungi in the air cleaner HEPA filters from ADCPHs in Korea.

  6. Mold Occurring on the Air Cleaner High-Efficiency Particulate Air Filters Used in the Houses of Child Patients with Atopic Dermatitis

    PubMed Central

    Kim, Seong Hwan; Ahn, Geum Ran; Son, Seung Yeol; Bae, Gwi-Nam

    2014-01-01

    Fungi are the known sources of irritation associated with atopic diseases (e.g., asthma, allergic rhinoconjunctivitis, and atopic eczema). To quantitatively estimate their presence in the indoor environment of atopic dermatitis-inflicted child patient's houses (ADCPHs), the high-efficiency particulate air (HEPA) filters installed inside the air cleaners of three different ADCPHs were investigated for the presence of mold. The air cleaner HEPA filters obtained from the three different ADCPHs were coded as HEPA-A, -B, and -C, respectively, and tested for the presence of mold. The colony forming units (CFUs) corresponding to the HEPA-A, -B, and -C filters were estimated to be 6.51 × 102 ± 1.50 × 102 CFU/cm2, 8.72 × 102 ± 1.69 × 102 CFU/cm2, and 9.71 × 102 ± 1.35 × 102 CFU/cm2, respectively. Aspergillus, Penicillium, Alternaria, Cladosporium, Trichoderma, and other fungal groups were detected in the 2,494 isolates. The distribution of these fungal groups differed among the three filters. Cladosporium was the major fungal group in filters HEPA-A and -C, whereas Penicillium was the major fungal group in the filter HEPA-B. Nine fungal species, including some of the known allergenic species, were identified in these isolates. Cladosporium cladosporioides was the most common mold among all the three filters. This is the first report on the presence of fungi in the air cleaner HEPA filters from ADCPHs in Korea. PMID:25346608

  7. Mold occurring on the air cleaner high-efficiency particulate air filters used in the houses of child patients with atopic dermatitis.

    PubMed

    Kim, Seong Hwan; Ahn, Geum Ran; Son, Seung Yeol; Bae, Gwi-Nam; Yun, Yeo Hong

    2014-09-01

    Fungi are the known sources of irritation associated with atopic diseases (e.g., asthma, allergic rhinoconjunctivitis, and atopic eczema). To quantitatively estimate their presence in the indoor environment of atopic dermatitis-inflicted child patient's houses (ADCPHs), the high-efficiency particulate air (HEPA) filters installed inside the air cleaners of three different ADCPHs were investigated for the presence of mold. The air cleaner HEPA filters obtained from the three different ADCPHs were coded as HEPA-A, -B, and -C, respectively, and tested for the presence of mold. The colony forming units (CFUs) corresponding to the HEPA-A, -B, and -C filters were estimated to be 6.51 × 10(2) ± 1.50 × 10(2) CFU/cm(2), 8.72 × 10(2) ± 1.69 × 10(2) CFU/cm(2), and 9.71 × 10(2) ± 1.35 × 10(2) CFU/cm(2), respectively. Aspergillus, Penicillium, Alternaria, Cladosporium, Trichoderma, and other fungal groups were detected in the 2,494 isolates. The distribution of these fungal groups differed among the three filters. Cladosporium was the major fungal group in filters HEPA-A and -C, whereas Penicillium was the major fungal group in the filter HEPA-B. Nine fungal species, including some of the known allergenic species, were identified in these isolates. Cladosporium cladosporioides was the most common mold among all the three filters. This is the first report on the presence of fungi in the air cleaner HEPA filters from ADCPHs in Korea. PMID:25346608

  8. You Can Help Keep the Air Cleaner -- Every Day

    MedlinePlus

    ... Can Help Keep the Air Cleaner -- Every Day! Air pollution can affect your health and the environment. There ... every one of us can take to reduce air pollution and keep the air cleaner, and precautionary measures ...

  9. Enzymes Enhance Biofilm Removal Efficiency of Cleaners

    PubMed Central

    Stiefel, Philipp; Mauerhofer, Stefan; Schneider, Jana; Maniura-Weber, Katharina; Rosenberg, Urs

    2016-01-01

    Efficient removal of biofilms from medical devices is a big challenge in health care to avoid hospital-acquired infections, especially from delicate devices like flexible endoscopes, which cannot be reprocessed using harsh chemicals or high temperatures. Therefore, milder solutions such as enzymatic cleaners have to be used, which need to be carefully developed to ensure efficacious performance. In vitro biofilm in a 96-well-plate system was used to select and optimize the formulation of novel enzymatic cleaners. Removal of the biofilm was quantified by crystal violet staining, while the disinfecting properties were evaluated by a BacTiter-Glo assay. The biofilm removal efficacy of the selected cleaner was further tested by using European standard (EN) for endoscope cleaning EN ISO 15883, and removal of artificial blood soil was investigated by treating TOSI (Test Object Surgical Instrument) cleaning indicators. Using the process described here, a novel enzymatic endoscope cleaner was developed, which removed 95% of Staphylococcus aureus and 90% of Pseudomonas aeruginosa biofilms in the 96-well plate system. With a >99% reduction of CFU and a >90% reduction of extracellular polymeric substances, this cleaner enabled subsequent complete disinfection and fulfilled acceptance criteria of EN ISO 15883. Furthermore, it efficiently removed blood soil and significantly outperformed comparable commercial products. The cleaning performance was stable even after storage of the cleaner for 6 months. It was demonstrated that incorporation of appropriate enzymes into the cleaner enhanced performance significantly. PMID:27044552

  10. Transport solutions for cleaner air.

    PubMed

    Kelly, Frank J; Zhu, Tong

    2016-05-20

    In cities across the globe, road transport remains an important source of air pollutants that are linked with acute and chronic health effects. Decreasing vehicle emissions--while maintaining or increasing commuter journeys--remains a major challenge for city administrators. In London, congestion-charging and a citywide low-emission zone failed to bring nitrogen dioxide concentrations under control. In Beijing, controls on the purchase and use of cars have not decreased transport emissions to a sufficient extent. As cities continue to grow, not even zero-emission vehicles are the solution. Moving increasingly large numbers of people efficiently around a city can only be achieved by expanding mass transit systems.

  11. 21 CFR 880.5045 - Medical recirculating air cleaner.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical recirculating air cleaner. 880.5045... Therapeutic Devices § 880.5045 Medical recirculating air cleaner. (a) Identification. A medical recirculating air cleaner is a device used to remove particles from the air for medical purposes. The device...

  12. 21 CFR 880.5045 - Medical recirculating air cleaner.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical recirculating air cleaner. 880.5045... Therapeutic Devices § 880.5045 Medical recirculating air cleaner. (a) Identification. A medical recirculating air cleaner is a device used to remove particles from the air for medical purposes. The device...

  13. 21 CFR 880.5045 - Medical recirculating air cleaner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical recirculating air cleaner. 880.5045... Therapeutic Devices § 880.5045 Medical recirculating air cleaner. (a) Identification. A medical recirculating air cleaner is a device used to remove particles from the air for medical purposes. The device...

  14. Transport solutions for cleaner air.

    PubMed

    Kelly, Frank J; Zhu, Tong

    2016-05-20

    In cities across the globe, road transport remains an important source of air pollutants that are linked with acute and chronic health effects. Decreasing vehicle emissions--while maintaining or increasing commuter journeys--remains a major challenge for city administrators. In London, congestion-charging and a citywide low-emission zone failed to bring nitrogen dioxide concentrations under control. In Beijing, controls on the purchase and use of cars have not decreased transport emissions to a sufficient extent. As cities continue to grow, not even zero-emission vehicles are the solution. Moving increasingly large numbers of people efficiently around a city can only be achieved by expanding mass transit systems. PMID:27199415

  15. RECLAIM: California's guarantee for cleaner air

    SciTech Connect

    Ross, C.P. )

    1994-07-01

    California's south coast air basin--the Los Angeles area--suffers the worst air pollution in the US, even after a history of extraordinary actions taken to reduce pollution. Existing regulations are tough and demanding, but must be changed to achieve federal clean air health standards by 2010. The Southern California business community and public are aggressively pursuing use of market incentives to lower the cost of achieving cleaner air. The South Coast Air Quality Management District (SCAQMD) is developing an alternative market-based regulatory approach called the Regional Clean Air Incentives Market (RECLAIM) program. RECLAIM has the potential to clean up air more effectively than traditional regulations by harnessing the power of the marketplace. Compared to the existing Air Quality Management Plan (AQMP), RECLAIM is designed to ensure that the program achieves equivalent emission reductions, an equal or greater level of enforcement, lower implementation costs, fewer job impacts and no adverse public health impacts.

  16. Integrated Technology Air Cleaners (ITAC): Design and Evaluation

    SciTech Connect

    Fisk, William J.; Cohn, Sebastian; Destaillats, Hugo; Henzel, Victor; Sidheswaran, Meera; Sullivan, Douglas P.

    2013-09-13

    The primary objective of this project was to design, build, and test an air cleaner for residential use with the potential to substantially improve indoor air quality, or maintain indoor air quality unchanged, when outdoor air ventilation rates are reduced to save energy. Two air cleaners were designed and fabricated. The design targets for airflow rate, fan power, and projected cost were met. In short term laboratory studies, both units performed as expected; however, during field studies in homes, the formaldehyde removal performance of the air cleaners was much lower than expected. In subsequent laboratory studies, incomplete decomposition of some indoor air volatile organic compounds, with formaldehyde as a product of partial decomposition of volatile organic compounds, was confirmed as the explanation for the poor formaldehyde removal performance in the field studies. The amount of formaldehyde produced per unit of decomposition of other volatile organic compounds was substantially diminished by increasing the amount of catalyst on the filter and also by decreasing the air velocity. Together, these two measures reduced formaldehyde production, per unit destruction of other volatile organic compounds, by a factor of four, while increasing the removal efficiency of volatile organic compounds by a factor of 1.4. A company with a southern California office is conducting studies in conjunction with Lawrence Berkeley National Laboratory, with the goal of incorporating the ITAC catalytic air cleaning technology in their future commercial products.

  17. Guide to Air Cleaners in the Home

    MedlinePlus

    ... Air Duct Cleaning Asthma Health, Energy Efficiency and Climate Change Flood Cleanup Home Remodel Indoor airPLUS Mold Radon ... menu Learn the Issues Air Chemicals and Toxics Climate Change Emergencies Greener Living Health and Safety Land and ...

  18. COMPUTATIONS ON THE PERFORMANCE OF PARTICLE FILTERS AND ELECTRONIC AIR CLEANERS

    EPA Science Inventory

    The paper discusses computations on the performance of particle filters and electronic air cleaners (EACs). The collection efficiency of particle filters and ACs is calculable if certain factors can be assumed or calibrated. For fibrous particulate filters, measurement of colle...

  19. 21 CFR 880.5045 - Medical recirculating air cleaner.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical recirculating air cleaner. 880.5045... (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5045 Medical recirculating air cleaner. (a) Identification. A medical...

  20. 21 CFR 880.5045 - Medical recirculating air cleaner.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical recirculating air cleaner. 880.5045... (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5045 Medical recirculating air cleaner. (a) Identification. A medical...

  1. Ultrafine particle removal and generation by portable air cleaners

    NASA Astrophysics Data System (ADS)

    Waring, Michael S.; Siegel, Jeffrey A.; Corsi, Richard L.

    Portable air cleaners can both remove and generate pollutants indoors. To investigate these phenomena, we conducted a two-phase investigation in a 14.75 m 3 stainless steel chamber. In the first phase, particle size-resolved (12.6-514 nm diameter) clean air delivery rates (CADR) and efficiencies were determined, as were ozone emission rates, for two high-efficiency particle arresting (HEPA) filters, one electrostatic precipitator with a fan, and two ion generators without fans. The two HEPA air cleaners had count average CADR (standard deviation) of 188 (30) and 324 (44) m 3 h -1; the electrostatic precipitator 284 (62) m 3 h -1; and the two ion generators 41 (11) and 35 (13) m 3 h -1. The electrostatic precipitator emitted ozone at a rate of 3.8±0.2 mg h -1, and the two ion generators 3.3±0.2 and 4.3±0.2 mg h -1. Ozone initiates reactions with certain unsaturated organic compounds that produce ultrafine and fine particles, carbonyls, other oxidized products, and free radicals. During the second phase, five different ion generators were operated separately in the presence of a plug-in liquid or solid air freshener, representing a strong terpene source. For air exchange rates of between 0.49 and 0.96 h -1, three ion generators acted as steady-state net particle generators in the entire measured range of 4.61-157 nm, and two generated particles in the range of approximately 10 to 39-55 nm. Terpene and aldehyde concentrations were also sampled for one ion generator, and concentrations of terpenes decreased and formaldehyde increased. Given these results, the pollutant removal benefits of ozone-generating air cleaners may be outweighed by the generation of indoor pollution.

  2. On-site application of air cleaner emitting plasma ion to reduce airborne contaminants in pig building

    NASA Astrophysics Data System (ADS)

    Cho, Man Su; Ko, Han Jong; Kim, Daekeun; Kim, Ki Youn

    2012-12-01

    The objective of this field study is to evaluate temporal reduction efficiency of air cleaner emitting plasma ion on airborne pollutants emitted from pig building. The operation principle of air cleaner based on plasma ion is that hydrogen atoms and oxygen ions combine to form hydroperoxyl radicals (HOO-), which surround and attach to surface of airborne microorganisms and eliminate them by breaking the hydrogen bond in their protein structure. In gaseous pollutants, it was found that there is no reduction effect of the air cleaner on ammonia and hydrogen sulfide (p > 0.05). In particulate pollutants, the air cleaner showed mean 79%(±6.1) and 78%(±3.0) of reduction efficiency for PM2.5. and PM1, respectively, compared to the control without air cleaner (p < 0.05). However, there is no significant difference in TSP and PM10 between the treatment with air cleaner and the control without air cleaner (p > 0.05). In biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi by application of air cleaner were 22%(±6.6) and 25%(±8.7), respectively (p < 0.05). Based on the results obtained from this study, it was concluded that the air cleaner had a positive reduction effect on PM2.5, PM1, airborne bacteria and airborne fungi among airborne pollutants distributed in pig building while it did not lead to significant reduction of ammonia and hydrogen sulfide.

  3. Control of asthma triggers in indoor air with air cleaners: a modeling analysis

    PubMed Central

    Myatt, Theodore A; Minegishi, Taeko; Allen, Joseph G; MacIntosh, David L

    2008-01-01

    Background Reducing exposure to environmental agents indoors shown to increase asthma symptoms or lead to asthma exacerbations is an important component of a strategy to manage asthma for individuals. Numerous investigations have demonstrated that portable air cleaning devices can reduce concentrations of asthma triggers in indoor air; however, their benefits for breathing problems have not always been reproducible. The potential exposure benefits of whole house high efficiency in-duct air cleaners for sensitive subpopulations have yet to be evaluated. Methods We used an indoor air quality modeling system (CONTAM) developed by NIST to examine peak and time-integrated concentrations of common asthma triggers present in indoor air over a year as a function of natural ventilation, portable air cleaners, and forced air ventilation equipped with conventional and high efficiency filtration systems. Emission rates for asthma triggers were based on experimental studies published in the scientific literature. Results Forced air systems with high efficiency filtration were found to provide the best control of asthma triggers: 30–55% lower cat allergen levels, 90–99% lower risk of respiratory infection through the inhalation route of exposure, 90–98% lower environmental tobacco smoke (ETS) levels, and 50–75% lower fungal spore levels than the other ventilation/filtration systems considered. These results indicate that the use of high efficiency in-duct air cleaners provide an effective means of controlling allergen levels not only in a single room, like a portable air cleaner, but the whole house. Conclusion These findings are useful for evaluating potential benefits of high efficiency in-duct filtration systems for controlling exposure to asthma triggers indoors and for the design of trials of environmental interventions intended to evaluate their utility in practice. PMID:18684328

  4. RESIDENTIAL AIR CLEANERS: A SUMMARY OF AVAILABLE INFORMATION

    EPA Science Inventory

    This publication will provide up-to-date information on the types of air cleaners available to the consumer, provides available information on their general effectiveness in removing indoor air pollutants, discusses some factors to consider in deciding whether to use an air-clean...

  5. Control of Respirable Particles in Indoor Air with Portable AirCleaners

    SciTech Connect

    Offermann, F.J.; Sextro, R.G.; Fisk, W.J.; Grimsrud, D.T.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.L.; Yater, J.

    1984-10-01

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles using in situ chamber decay tests. Following injection of cigarette smoke in a room-size chamber, decay rates for particle concentrations were obtained for total number concentration and for number concentration by particle size with and without air cleaner operation. The size distribution of the tobacco smoke particles was log normal with a count median diameter of 0.15 {micro}m and a geometric standard deviation of 2.0. Without air cleaner operation, the natural mass-averaged surface deposition rate of particles was observed to be 0.1 h{sup -1}. Air cleaning rates for particles were found to be negligible for several small panel-filter devices, a residential-sized ion-generator, and a pair of mixing fans. Electrostatic precipitators and extended surface filters removed particles at substantial rates, and a HEPA-type filter was the most efficient air cleaner studied.

  6. Control of respirable particles in indoor air with portable air cleaners

    NASA Astrophysics Data System (ADS)

    Offermann, F. J.; Sextro, R. G.; Fisk, W. J.; Grimsrud, D. T.; Nazaroff, W. W.; Nero, A. V.; Revzan, K. L.; Yater, J.

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles using in situ chamber decay tests. Following injection of cigarette smoke in a room-size chamber, decay rates for particle concentrations were obtained for total number concentration and for number concentration by particle size with and without air cleaner operation. The size distribution of the tobacco smoke particles was log normal with a count median diameter of 0.15 μm and a geometric standard deviation of 2.0. Without air cleaner operation, the natural mass-averaged surface deposition rate of particles was observed to be 0.1 h -1. Air cleaning rates for particles were found to be negligible for several small panel-filter devices, a residential-sized ion-generator, and a pair of mixing fans. Electrostatic precipitators and extended surface filters removed particles at substantial rates, and a HEPA-type filter was most efficient air cleaner studied.

  7. Dynamic monitoring of the dust pickup efficiency of vacuum cleaners.

    PubMed

    Reponen, Tiina; Trakumas, Saulius; Willeke, Klaus; Grinshpun, Sergey A; Choe, Kyoo T; Friedman, Warren

    2002-01-01

    This study evaluated a new method that uses an optical aerosol photometer for dynamically monitoring dust pickup efficiency during vacuuming. In the first stage of this study the new method was compared with built-in dirt sensors installed by vacuum cleaner manufacturers. Through parallel testing it has been shown that the widely available built-in dirt sensors are not sensitive enough to register small (< 53 microm) dust particles. Therefore, only the optical photometer was used in the rest of the experiments of this study to monitor the dust pickup efficiency while the vacuum cleaner was operated with different nozzles on clean and soiled carpet and vinyl sheet flooring. This method also was used to monitor dust pickup efficiency when vacuuming carpets originating from lead-contaminated homes. The dust pickup efficiencies obtained with the optical aerosol photometer have been compared with the surface lead concentrations found during different stages of cleaning. Results indicate that the dust mass concentration registered with the optical aerosol photometer at the nozzle outlet correlates well with the dust mass collected in the vacuum cleaner filter bag and with the surface lead level. Therefore, dynamic dust pickup monitoring can provide valuable information about the efficiency of cleaning when a vacuum cleaner is used. This suggests that a small aerosol photometer similar to a light-scattering smoke detector would be beneficial in vacuum cleaners used for cleaning surfaces contaminated with leaded dust and biological particles (including allergens). PMID:12570075

  8. Cleaner Air for Home and Office

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Increased insulation has led to higher concentrations in homes and offices of toxic chemicals caused by emissions from synthetic building components. Recent NASA research regarding future interplanetary manned spacecraft has shown that certain plants can absorb gasses, reducing indoor air pollution. After working with water purifying water hyacinths, Dr. B. C. Wolverton at NSTL developed a carbon/plant filter system to remove chemicals, smoke, etc. Two companies have commercialized the system. Bio-safe provides plants, a bed of activated carbon and an air pump installed near the plant's roots. Pollutants are trapped by the charcoal and either digested by the roots or broken down by microorganisms. Purified air is then directed back into the room. Applied Indoor Resource Company markets Bio-Pure, which includes plants on a layer of patented soil medium with activated carbon. Legumes and mosses filter the air; a blower moves air through the filtering system for cleansing by microorganisms. Research at NSTL continues, and the system may eventually be enlarged.

  9. IMPROVED TEST METHODS FOR ELECTRONIC AIR CLEANERS

    EPA Science Inventory

    The objective of this project was to develop a fractional filtration efficiency test protocol for residential electrostatic precipitators (ESPs) that avoids the limitations of the ASHRAE 52.2 method. Specifically, the objectives were to a) determine the change in efficiency that ...

  10. Impacts of air cleaners on indoor air quality in residences impacted by wood smoke.

    PubMed

    Wheeler, Amanda J; Gibson, Mark D; MacNeill, Morgan; Ward, Tony J; Wallace, Lance A; Kuchta, James; Seaboyer, Matt; Dabek-Zlotorzynska, Ewa; Guernsey, Judith Read; Stieb, David M

    2014-10-21

    Residential wood combustion is an important source of ambient air pollution, accounting for over 25% of fine particulate matter (PM2.5) emissions in Canada. In addition to these ambient contributions, wood smoke pollutants can enter the indoor environment directly when loading or stoking stoves, resulting in a high potential for human exposure. A study of the effectiveness of air cleaners at reducing wood smoke-associated PM2.5 of indoor and outdoor origin was conducted in 31 homes during winter 2009-10. Day 1, the residents' wood burning appliance operated as usual with no air cleaner. Days 2 and 3, the wood burning appliance was not operational and the air cleaner was randomly chosen to operate in "filtration" or "placebo filtration" mode. When the air cleaner was operating, total indoor PM2.5 levels were significantly lower than on placebo filtration days (p = 0.0001) resulting in a median reduction of 52%. There was also a reduction in the median PM2.5 infiltration factor from 0.56 to 0.26 between these 2 days, suggesting the air cleaner was responsible for increased PM2.5 deposition on filtration days. Our findings suggest that the use of an air cleaner reduces exposure to indoor PM2.5 resulting from both indoor and ambient wood smoke sources. PMID:25247985

  11. Control of respirable particles and radon progeny with portable air cleaners

    SciTech Connect

    Offermann, F.J.; Sextro, R.G.; Fisk, W.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.L.; Yater, J.

    1984-02-01

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles and radon progeny. Following injection of cigarette smoke and radon in a room-size chamber, decay rates for particles and radon progeny concentrations were measured with and without air cleaner operation. Particle concentrations were obtained for total number concentration and for number concentration by particle size. In tests with no air cleaner the natural decay rate for cigarette smoke was observed to be 0.2 hr/sup -1/. Air cleaning rates for particles were found to be negligible for several small panel-filters, a residential ion-generator, and a pair of mixing fans. The electrostatic precipitators and extended surface filters tested had significant particle removal rates, and a HEPA-type filter was the most efficient air cleaner. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in removing radon progeny. At low particle concentrations plateout of the unattached radon progeny is an important removal mechanism. Based on data from these tests, the plateout rate for unattached progeny was found to be 15 hr/sup -1/. The unattached fraction and the overall removal rate due to deposition of attached and unattached nuclides have been estimated for each radon decay product as a function of particle concentration. While air cleaning can be effective in reducing total radon progeny, concentrations of unattached radon progeny can increase with increasing air cleaning. 39 references, 26 figures, 9 tables.

  12. Air cleaners for indoor-air-pollution control (Chapter 10). Book chapter, Feb 89-Jul 90

    SciTech Connect

    Viner, A.S.; Ramanathan, K.; Hanley, J.T.; Smith, D.D.; Ensor, D.S.

    1991-01-01

    The chapter describes an experimental study to evaluate performance characteristics of currently available controls for indoor air pollutants, including both particles and gases. The study evaluated the particle-size-dependent collection efficiency of seven commercially available devices for particulate control: a common furnace filter, four industrial filters, and two electronic air cleaners (EACs). The furnance filter had negligible effect on particles with diameters between 0.1 and 1 micrometer. The industrial filters, with ASHRAE ratings of 95, 85, 65, and 40% showed minimum efficiency at about 0.1 micrometer, which was substantially less than the ASHRAE efficiency. One EAC, essentially a furnance filter with a high-voltage electrode, reached a maximum efficiency of 30% at low flowrates (7 cu m/min); however, it had a negligible effect at higher flowrates. The other EAC, similar to an industrial ESP, showed efficiencies of 80-90% over the entire size range at low to moderate flowrates. At the highest flowrate, a minimum efficiency was detected at 0.35 micrometer. The study also evaluated the suitability of commerically available carbon-based sorbents (wood, coal, and coconut) for removing low concentrations of volatile organic compounds (benzene, acetaldehyde, and 1,1,1-trichloroethane).

  13. Evaluation of a Combined Ultraviolet Photocatalytic Oxidation(UVPCO)/Chemisorbent Air Cleaner for Indoor Air Applications

    SciTech Connect

    Hodgson, Alfred T.; Destaillats, Hugo; Hotchi, Toshifumi; Fisk,William J.

    2007-02-01

    We previously reported that gas-phase byproducts of incomplete oxidation were generated when a prototype ultraviolet photocatalytic oxidation (UVPCO) air cleaner was operated in the laboratory with indoor-relevant mixtures of VOCs at realistic concentrations. Under these conditions, there was net production of formaldehyde and acetaldehyde, two important indoor air toxicants. Here, we further explore the issue of byproduct generation. Using the same UVPCO air cleaner, we conducted experiments to identify common VOCs that lead to the production of formaldehyde and acetaldehyde and to quantify their production rates. We sought to reduce the production of formaldehyde and acetaldehyde to acceptable levels by employing different chemisorbent scrubbers downstream of the UVPCO device. Additionally, we made preliminary measurements to estimate the capacity and expected lifetime of the chemisorbent media. For most experiments, the system was operated at 680-780 m{sup 3}/h (400-460 cfm). A set of experiments was conducted with common VOCs introduced into the UVPCO device individually and in mixture. Compound conversion efficiencies and the production of formaldehyde and acetaldehyde were determined by comparison of compound concentrations upstream and downstream of the reactor. There was general agreement between compound conversions efficiencies determined individually and in the mixture. This suggests that competition among compounds for active sites on the photocatalyst surface will not limit the performance of the UVPCO device when the total VOC concentration is low. A possible exception was the very volatile alcohols, for which there were some indications of competitive adsorption. The results also showed that formaldehyde was produced from many commonly encountered VOCs, while acetaldehyde was generated by specific VOCs, particularly ethanol. The implication is that formaldehyde concentrations are likely to increase when an effective UVPCO air cleaner is used in

  14. POLLUTION PREVENTION FOR CLEANER AIR: EPA'S AIR AND ENERGY ENGINEERING RESEARCH LABORATORY

    EPA Science Inventory

    The article discusses the role of EPA's Air and Energy Engineering Research Laboratory (AEERL) in pollution prevention research for cleaner air. For more than 20 years, AEERL has been conducting research to identify control approaches for the pollutants and sources which contribu...

  15. Removing seed coat fragments with a lint cleaner grid bar air knife

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Seed coat fragments (SCF) in ginned lint cause spinning problems at the textile mill and undesirable defects in finished goods. Work continued on developing an air knife that may help remove SCF from ginned lint. The air knife is mounted on the 1st lint cleaner grid bar of a saw-type lint cleaner,...

  16. Infiltration of forest fire and residential wood smoke: an evaluation of air cleaner effectiveness.

    PubMed

    Barn, Prabjit; Larson, Timothy; Noullett, Melanie; Kennedy, Susan; Copes, Ray; Brauer, Michael

    2008-09-01

    Communities impacted by fine-particle air pollution (particles with an aerodynamic diameter less than 2.5 microm; PM(2.5)) from forest fires and residential wood burning require effective, evidence-based exposure-reduction strategies. Public health recommendations during smoke episodes typically include advising community members to remain indoors and the use of air cleaners, yet little information is available on the effectiveness of these measures. Our study attempted to address the following objectives: to measure indoor infiltration factor (F(inf)) of PM(2.5) from forest fires/wood smoke, to determine the effectiveness of high-efficiency particulate air (HEPA) filter air cleaners in reducing indoor PM(2.5), and to analyze the home determinants of F(inf) and air cleaner effectiveness (ACE). We collected indoor/outdoor 1-min PM(2.5) averages and 48-h outdoor PM(2.5) filter samples for 21 winter and 17 summer homes impacted by wood burning and forest fire smoke, respectively, during 2004-2005. A portable HEPA filter air cleaner was operated indoors with the filter removed for one of two sampling days. Particle F(inf) and ACE were calculated for each home using a recursive model. We found mean F(inf)+/-SD was 0.27+/-0.18 and 0.61+/-0.27 in winter (n=19) and summer (n=13), respectively, for days when HEPA filters were not used. Lower F(inf)+/-SD values of 0.10+/-0.08 and 0.19+/-0.20 were found on corresponding days when HEPA filters were in place. Mean+/-SD ACE ([F(inf) without filter-F(inf) with filter]/F(inf) without filter) in winter and summer were 55+/-38% and 65+/-35%, respectively. Number of windows and season predicted F(inf) (P<0.001). No significant predictors of ACE were identified. Our findings show that remaining indoors combined with use of air cleaner can effectively reduce PM(2.5) exposure during forest fires and residential wood burning. PMID:18059421

  17. The effectiveness of an air cleaner in controlling droplet/aerosol particle dispersion emitted from a patient's mouth in the indoor environment of dental clinics.

    PubMed

    Chen, Chun; Zhao, Bin; Cui, Weilin; Dong, Lei; An, Na; Ouyang, Xiangying

    2010-07-01

    Dental healthcare workers (DHCWs) are at high risk of occupational exposure to droplets and aerosol particles emitted from patients' mouths during treatment. We evaluated the effectiveness of an air cleaner in reducing droplet and aerosol contamination by positioning the device in four different locations in an actual dental clinic. We applied computational fluid dynamics (CFD) methods to solve the governing equations of airflow, energy and dispersion of different-sized airborne droplets/aerosol particles. In a dental clinic, we measured the supply air velocity and temperature of the ventilation system, the airflow rate and the particle removal efficiency of the air cleaner to determine the boundary conditions for the CFD simulations. Our results indicate that use of an air cleaner in a dental clinic may be an effective method for reducing DHCWs' exposure to airborne droplets and aerosol particles. Further, we found that the probability of droplet/aerosol particle removal and the direction of airflow from the cleaner are both important control measures for droplet and aerosol contamination in a dental clinic. Thus, the distance between the air cleaner and droplet/aerosol particle source as well as the relative location of the air cleaner to both the source and the DHCW are important considerations for reducing DHCWs' exposure to droplets/aerosol particles emitted from the patient's mouth during treatments.

  18. The effectiveness of an air cleaner in controlling droplet/aerosol particle dispersion emitted from a patient's mouth in the indoor environment of dental clinics

    PubMed Central

    Chen, Chun; Zhao, Bin; Cui, Weilin; Dong, Lei; An, Na; Ouyang, Xiangying

    2010-01-01

    Dental healthcare workers (DHCWs) are at high risk of occupational exposure to droplets and aerosol particles emitted from patients' mouths during treatment. We evaluated the effectiveness of an air cleaner in reducing droplet and aerosol contamination by positioning the device in four different locations in an actual dental clinic. We applied computational fluid dynamics (CFD) methods to solve the governing equations of airflow, energy and dispersion of different-sized airborne droplets/aerosol particles. In a dental clinic, we measured the supply air velocity and temperature of the ventilation system, the airflow rate and the particle removal efficiency of the air cleaner to determine the boundary conditions for the CFD simulations. Our results indicate that use of an air cleaner in a dental clinic may be an effective method for reducing DHCWs' exposure to airborne droplets and aerosol particles. Further, we found that the probability of droplet/aerosol particle removal and the direction of airflow from the cleaner are both important control measures for droplet and aerosol contamination in a dental clinic. Thus, the distance between the air cleaner and droplet/aerosol particle source as well as the relative location of the air cleaner to both the source and the DHCW are important considerations for reducing DHCWs' exposure to droplets/aerosol particles emitted from the patient's mouth during treatments. PMID:20031985

  19. Mist control at a machining center, Part 2: Mist control following installation of air cleaners.

    PubMed

    Yacher, J M; Heitbrink, W A; Burroughs, G E

    2000-01-01

    At a machining center used to produce transaxle and transmission parts, aerosol instrumentation was used to quantitatively evaluate size-dependent mist generation of a synthetic metalworking fluid (MWF) consisting primarily of water and triethanolamine (TEA). This information was used to select an air cleaner for controlling the mist. During most machining operations, the MWF was flooded over the part. These machining operations were performed in a nearly complete enclosure that was exhausted to an air cleaner consisting of three sections: a fall-out chamber, a trifilter section to capture metal chips and mist, and a 1.13 m3/sec (2400 ft3/min) blower. The partnering company requested that National Institute for Occupational Safety and Health (NIOSH) researchers perform an evaluation of the effectiveness of a commercially available air cleaner. After NIOSH researchers characterized mist generation at the machining centers and found that performance of a test air cleaner appeared to be suitable, the company installed more than 25 air cleaners on different machining centers in this plant and enclosed the corresponding fluid filtration unit. The facility also has implemented a maintenance program for the air cleaners that involves regularly scheduled filter changes; performance is ensured by monitoring static pressure. A NIOSH-conducted air sampling evaluation showed that area TEA concentrations were reduced from a geometric mean of 0.25 to 0.03 mg/m3. Personal total particulate concentrations were reduced from a geometric mean of 0.22 to 0.06 mg/m3. These results show the effectiveness of this combination of enclosure, ventilation, and filtration to greatly reduce the exposure to MWF mist generated in modern machining centers.

  20. IMPACT OF AN OZONE GENERATOR AIR CLEANER ON STYRENE CONCENTRATIONS IN AN INDOOR AIR QUALITY RESEARCH CHAMBER

    EPA Science Inventory

    The paper gives results of an investigation of the impact of an ozone generator air cleaner on vapor-phase styrene concentrations in a full-scale indoor air quality test chamber. The time history of the concentrations of styrene and ozone is well predicted by a simulation model u...

  1. Evaluation of ozone generation and indoor organic compounds removal by air cleaners based on chamber tests

    NASA Astrophysics Data System (ADS)

    Yu, Kuo-Pin; Lee, Grace Whei-May; Hsieh, Ching-Pei; Lin, Chi-Chi

    2011-01-01

    Ozone can cause many health problems, including exacerbation of asthma, throat irritation, cough, chest ache, shortness of breath, and respiratory infections. Air cleaners are one of the sources of indoor ozone, and thus the evaluation of ozone generated by air cleaners is desired significant issue. Most evaluation methods proposed are based on chamber tests. However, the adsorption and desorption of ozone on the wall of test chamber and the deposition of ozone resulted from the surface reaction can influence the evaluation results. In this study, we developed a mass balance model that took the adsorption, desorption and deposition of ozone into consideration to evaluate the effective ozone emission rates of six selected air cleaners. The experiments were conducted in a stainless steel chamber with a volume of 11.3 m 3 at 25 °C and 60% relative humidity. The adsorption, desorption and deposition rate constants of ozone obtained by fitting the model to the experimental data were k a = 0.149 ± 0.052 m h -1, k d = 0.013 ± 0.007 h -1, and k r = 0.050 ± 0.020 h -1, respectively. The effective ozone emission rates of Air Cleaners No. 1, 2, and 3 ranged between 13,400-24,500 μg h -1, 7190-10,400 μg h -1, and 4880-6560 μg h -1, respectively, which were more stable than those of No.4, 5, and 6. The effective ozone emission rates of Air Cleaners No. 4, 5, and 6 increased with the time of operation which might be relevant to the decrease of ozone removal by the "aging" filter installed in these cleaners. The removal of toluene and formaldehyde by these six air cleaners were also evaluated and the clean air delivery rates (CADRs) of these two pollutants ranged from non-detectable to 0.42 ± 0.08 m 3 h -1, and from non-detectable to 0.75 ± 0.07 m 3 h -1, respectively. The CADRs showed an insignificant relationship with the effective ozone emission rates. Thus, the removal of toluene and formaldehyde might be resulted from the adsorption on the filters and the

  2. New Technology Sparks Smoother Engines and Cleaner Air

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Automotive Resources, Inc. (ARI) has developed a new device for igniting fuel in engines-the SmartPlug.TM SmartPlug is a self-contained ignition system that may be retrofitted to existing spark-ignition and compression-ignition engines. The SmartPlug needs as little as six watts of power for warm-up, and requires no electricity at all when the engine is running. Unlike traditional spark plugs, once the SmartPlug ignites the engine, and the engine heats up, the power supply for the plug is no longer necessary. In the utility industry, SmartPlugs can be used in tractors, portable generators, compressors, and pumps. In addition to general-purpose applications, such as lawn mowers and chainsaws, SmartPlugs can also be used in the recreational, marine, aviation, and automotive industries. Unlike traditional ignition systems, the SmartPlug system requires no distributor, coil points, or moving parts. SmartPlugs are non-fouling, with a faster and cleaner burn than traditional spark plugs. They prevent detonation and are not sensitive to moisture, allowing them to be used on a variety of engines. Other advantages include no electrical noise, no high voltage, exceptionally high altitude capabilities, and better cold-start statistics than those of standard spark ignition systems. Future applications for the SmartPlug are being evaluated by manufacturers in the snowmobile industry.

  3. The trickle-down theory of cleaner air.

    PubMed Central

    Frazer, L

    2000-01-01

    The 1990 Clean Air Act Amendments prompted an increased urgency to find new ways to treat airstreams containing volatile organic compounds, which affect the nitrogen photolytic cycle and help produce ground-level ozone, hazardous air pollutants, and odorous air emissions such as hydrogen sulfide. Scientists at the New Jersey company Envirogen have adapted traditional biofiltration technology to perform airborne waste stream cleanup. Preliminary research on pollutants such as phenol, methylene chloride, benzene, and toluene indicates that Envirogen's biotrickling filter may remove an average of about 94% of total hazardous air pollutants. Scientists are working to identify microbes that will clean up more stubborn pollutants. PMID:10753107

  4. The Diesel Paradox: Why Dieselization Will Lead to Cleaner Air

    SciTech Connect

    Eberhardt, James J.

    2000-08-20

    There are challenges facing the U.S. and the world that are brought on by the growing demand for transporting people and goods. These include the growing consumption of petroleum, urban air pollution, and global climate change.

  5. NASA satellites point to cleaner U.S. air

    NASA Astrophysics Data System (ADS)

    Wendel, JoAnna

    2014-07-01

    People living in major U.S. cities now enjoy better air quality than they did a decade ago, according to satellite images released by NASA last month. Data from the agency's Ozone Monitoring Instrument (OMI) show that Americans are breathing less nitrogen dioxide, a yellow-brown gas that can cause respiratory problems. The gas is produced by the combustion of gasoline in vehicle engines and coal power plants.

  6. CHARACTERIZATION OF OZONE EMISSIONS FROM AIR CLEANERS EQUIPPED WITH OZONE GENERATORS AND SENSOR AND FEEDBACK CONTROL CIRCUITRY

    EPA Science Inventory

    The paper give results of a characterization of ozone emissions from air cleaners equipped with ozone generators and sensor and feedback control circuitry. Ozone emission rates of several consumer appliances, marketed as indoor air treatment or air purification systems, were det...

  7. Functional morphology and efficiency of the antenna cleaner in Camponotus rufifemur ants

    PubMed Central

    Hackmann, Alexander; Delacave, Henry; Robinson, Adam; Labonte, David; Federle, Walter

    2015-01-01

    Contamination of body surfaces can negatively affect many physiological functions. Insects have evolved different adaptations for removing contamination, including surfaces that allow passive self-cleaning and structures for active cleaning. Here, we study the function of the antenna cleaner in Camponotus rufifemur ants, a clamp-like structure consisting of a notch on the basitarsus facing a spur on the tibia, both bearing cuticular ‘combs’ and ‘brushes’. The ants clamp one antenna tightly between notch and spur, pull it through, and subsequently clean the antenna cleaner itself with the mouthparts. We simulated cleaning strokes by moving notch or spur over antennae contaminated with fluorescent particles. The notch removed particles more efficiently than the spur, but both components eliminated more than 60% of the particles with the first stroke. Ablation of bristles, brush and comb strongly reduced the efficiency, indicating that they are essential for cleaning. To study how comb and brush remove particles of different sizes, we contaminated antennae of living ants, and anaesthetized them immediately after they had performed the first cleaning stroke. Different-sized beads were trapped in distinct zones of the notch, consistent with the gap widths between cuticular outgrowths. This suggests that the antenna cleaner operates like a series of sieves that remove the largest objects first, followed by smaller ones, down to the smallest particles that get caught by adhesion. PMID:26587270

  8. Air transportation energy efficiency

    NASA Technical Reports Server (NTRS)

    Williams, L. J.

    1977-01-01

    The energy efficiency of air transportation, results of the recently completed RECAT studies on improvement alternatives, and the NASA Aircraft Energy Efficiency Research Program to develop the technology for significant improvements in future aircraft were reviewed.

  9. Traffic-related air pollution: Exposure and health effects in Copenhagen street cleaners and cemetery workers

    SciTech Connect

    Raaschou-Nielsen, O.; Nielsen, M.L.; Gehl, J.

    1995-05-01

    This questionaire-based study found a significantly higher prevalence of chronic bronchitis, asthma, and several other symptoms in 116 Copenhagen street cleaners who were exposed to traffic-related air pollution at levels that were slightly lower than the 1987 World Health Organization-recommended threshold values, compared with 115 Copenhagen cemetery workers exposed to lower pollution levels. Logistic regression analysis, controlling for age and smoking, was conducted, and odds ratios and 95% confidence intervals were calculated to be 2.5 for chronic bronchitis (95% confidence interval = 1.2-5.1), 2.3 for asthma (95% confidence interval = 1.0-5.1), and 1.8-7.9 for other symptoms (95% confidence interval = 1.0-28.2). Except for exposure to air pollution, the two groups were comparable, i.e., they had similar terms of employment and working conditions. the exposure ranges during an 8-h work day, averaged from readings taken at five monitored street positions, were: 41-257 ppb nitric oxide (1-h max: 865 ppb); 23-43 ppb nitrogen dioxide (1-h max: 208 ppb); 1.0-4.3 ppm carbon monoxide (8-h max: 7.1 ppm); 14-28 ppb sulfur dioxide (1-h max; 112 ppb); and 10-38 ppb ozone (1-h max: 72 ppb). 33 refs., 7 tabs.

  10. Experimental Study on Ultrafine Particle Removal Performance of Portable Air Cleaners with Different Filters in an Office Room.

    PubMed

    Ma, Huan; Shen, Henggen; Shui, Tiantian; Li, Qing; Zhou, Liuke

    2016-01-05

    Size- and time-dependent aerodynamic behaviors of indoor particles, including PM1.0, were evaluated in a school office in order to test the performance of air-cleaning devices using different filters. In-situ real-time measurements were taken using an optical particle counter. The filtration characteristics of filter media, including single-pass efficiency, volume and effectiveness, were evaluated and analyzed. The electret filter (EE) medium shows better initial removal efficiency than the high efficiency (HE) medium in the 0.3-3.5 μm particle size range, while under the same face velocity, the filtration resistance of the HE medium is several times higher than that of the EE medium. During service life testing, the efficiency of the EE medium decreased to 60% with a total purifying air flow of 25 × 10⁴ m³/m². The resistance curve rose slightly before the efficiency reached the bottom, and then increased almost exponentially. The single-pass efficiency of portable air cleaner (PAC) with the pre-filter (PR) or the active carbon granule filter (CF) was relatively poor. While PAC with the pre-filter and the high efficiency filter (PR&HE) showed maximum single-pass efficiency for PM1.0 (88.6%), PAC with the HE was the most effective at removing PM1.0. The enhancement of PR with HE and electret filters augmented the single-pass efficiency, but lessened the airflow rate and effectiveness. Combined with PR, the decay constant of large-sized particles could be greater than for PACs without PR. Without regard to the lifetime, the electret filters performed better with respect to resource saving and purification improvement. A most penetrating particle size range (MPPS: 0.4-0.65 μm) exists in both HE and electret filters; the MPPS tends to become larger after HE and electret filters are combined with PR. These results serve to provide a better understanding of the indoor particle removal performance of PACs when combined with different kinds of filters in school

  11. Experimental Study on Ultrafine Particle Removal Performance of Portable Air Cleaners with Different Filters in an Office Room

    PubMed Central

    Ma, Huan; Shen, Henggen; Shui, Tiantian; Li, Qing; Zhou, Liuke

    2016-01-01

    Size- and time-dependent aerodynamic behaviors of indoor particles, including PM1.0, were evaluated in a school office in order to test the performance of air-cleaning devices using different filters. In-situ real-time measurements were taken using an optical particle counter. The filtration characteristics of filter media, including single-pass efficiency, volume and effectiveness, were evaluated and analyzed. The electret filter (EE) medium shows better initial removal efficiency than the high efficiency (HE) medium in the 0.3–3.5 μm particle size range, while under the same face velocity, the filtration resistance of the HE medium is several times higher than that of the EE medium. During service life testing, the efficiency of the EE medium decreased to 60% with a total purifying air flow of 25 × 104 m3/m2. The resistance curve rose slightly before the efficiency reached the bottom, and then increased almost exponentially. The single-pass efficiency of portable air cleaner (PAC) with the pre-filter (PR) or the active carbon granule filter (CF) was relatively poor. While PAC with the pre-filter and the high efficiency filter (PR&HE) showed maximum single-pass efficiency for PM1.0 (88.6%), PAC with the HE was the most effective at removing PM1.0. The enhancement of PR with HE and electret filters augmented the single-pass efficiency, but lessened the airflow rate and effectiveness. Combined with PR, the decay constant of large-sized particles could be greater than for PACs without PR. Without regard to the lifetime, the electret filters performed better with respect to resource saving and purification improvement. A most penetrating particle size range (MPPS: 0.4–0.65 μm) exists in both HE and electret filters; the MPPS tends to become larger after HE and electret filters are combined with PR. These results serve to provide a better understanding of the indoor particle removal performance of PACs when combined with different kinds of filters in school

  12. Experimental Study on Ultrafine Particle Removal Performance of Portable Air Cleaners with Different Filters in an Office Room.

    PubMed

    Ma, Huan; Shen, Henggen; Shui, Tiantian; Li, Qing; Zhou, Liuke

    2016-01-01

    Size- and time-dependent aerodynamic behaviors of indoor particles, including PM1.0, were evaluated in a school office in order to test the performance of air-cleaning devices using different filters. In-situ real-time measurements were taken using an optical particle counter. The filtration characteristics of filter media, including single-pass efficiency, volume and effectiveness, were evaluated and analyzed. The electret filter (EE) medium shows better initial removal efficiency than the high efficiency (HE) medium in the 0.3-3.5 μm particle size range, while under the same face velocity, the filtration resistance of the HE medium is several times higher than that of the EE medium. During service life testing, the efficiency of the EE medium decreased to 60% with a total purifying air flow of 25 × 10⁴ m³/m². The resistance curve rose slightly before the efficiency reached the bottom, and then increased almost exponentially. The single-pass efficiency of portable air cleaner (PAC) with the pre-filter (PR) or the active carbon granule filter (CF) was relatively poor. While PAC with the pre-filter and the high efficiency filter (PR&HE) showed maximum single-pass efficiency for PM1.0 (88.6%), PAC with the HE was the most effective at removing PM1.0. The enhancement of PR with HE and electret filters augmented the single-pass efficiency, but lessened the airflow rate and effectiveness. Combined with PR, the decay constant of large-sized particles could be greater than for PACs without PR. Without regard to the lifetime, the electret filters performed better with respect to resource saving and purification improvement. A most penetrating particle size range (MPPS: 0.4-0.65 μm) exists in both HE and electret filters; the MPPS tends to become larger after HE and electret filters are combined with PR. These results serve to provide a better understanding of the indoor particle removal performance of PACs when combined with different kinds of filters in school

  13. The unattached fraction of radon decay products: Potential effects of in-home air cleaners on lung cancer risk

    SciTech Connect

    Brady, P.A.

    1991-01-01

    Radon decay products are a factor in the development of lung cancer. Because of their efficient deposition within the lung, the fraction of decay products not attached to particulate (i.e., the unattached fraction) is very important in lung dosimetry. This study simulated the use of two in-home air cleaning devices to reduce airborne particulate concentrations, measure the effect on the unattached fraction, and estimate the radon lung cancer risk. Radon was released into a chamber having a volume-to-surface-area ratio similar to a small home. At radon-decay product equilibrium, radon and airborne particle concentrations were measured, and the concentration of the unattached fraction was estimated. The effect of particle concentration on the unattached fraction was then determined. The average unattached fractions corresponding to the particle concentration ranges expected for the air cleaning devices were used to calculate the annual alpha radiation dose and annual radon lung cancer for men, women and children at rest and under light activity. The annual doses and related risks were compared to those used in the models published by the Environmental Protection Agency. For particulate concentrations of a home with no particulate generating activities (e.g., smoking, cooking), the electronic air cleaner is predicted to reduce the unattached fraction from seven percent (the value used by the NCRP and confirmed in this study) to four percent. These conditions represent the maximum reduction in the unattached fraction. The decrease in the unattached fraction is tentatively attributed to an increase in plateout. Based on these results, a reduction of less than ten percent in the calculated annual lung cancer risk is found in all cases.

  14. QFD analysis of RSRM aqueous cleaners

    NASA Technical Reports Server (NTRS)

    Marrs, Roy D.; Jones, Randy K.

    1995-01-01

    This paper presents a Quality Function Deployment (QFD) analysis of the final down-selected aqueous cleaners to be used on the Redesigned Solid Rocket Motor (RSRM) program. The new cleaner will replace solvent vapor degreasing. The RSRM Ozone Depleting Compound Elimination program is discontinuing the methyl chloroform vapor degreasing process and replacing it with a spray-in-air aqueous cleaning process. Previously, 15 cleaners were down-selected to two candidates by passing screening tests involving toxicity, flammability, cleaning efficiency, contaminant solubility, corrosion potential, cost, and bond strength. The two down-selected cleaners were further evaluated with more intensive testing and evaluated using QFD techniques to assess suitability for cleaning RSRM case and nozzle surfaces in preparation for adhesive bonding.

  15. Cleaner production and methodological proposal of eco-efficiency measurement in a Mexican petrochemical complex.

    PubMed

    Morales, M A; Herrero, V M; Martínez, S A; Rodríguez, M G; Valdivieso, E; Garcia, G; de los Angeles Elías, Maria

    2006-01-01

    Abstract In the frame of the Petróleos Mexicanos Institutional Program for Sustainable Development, processes were evaluated in the manufacture operation of the petrochemical industry, with the purpose of reducing their ecological fingerprint. Thirteen cleaner production opportunities were registered in six process plants: ethylene oxide and glycols, acetaldehyde, ethylene, high density polyethylene, polypropylene switch and acrylonitrile, and 45 recommendations in the waste water treatment plant. Morelos is the second most important petrochemical complex in the Mexican and Latin American petrochemical industry. A tool was developed to obtain eco-efficiency indicators in operation processes, and as a result, potential savings were obtained based on best performance, as well as the integrated distribution of Sankey diagrams. Likewise, a mechanism of calculation to obtain economic savings based on the reduction of residues during the whole productive process is proposed. These improvement opportunities and recommendations will result in economic and environmental benefits minimising the use of water, efficient use of energy, raw materials and reducing residues from source, generating less environmental impacts during the process.

  16. High efficiency air cycle air conditioning system

    SciTech Connect

    Rannenberg, G. C.

    1985-11-19

    An air cycle air conditioning system is provided with regenerative heat exchangers upstream and downstream of an expansion turbine. A closedloop liquid circulatory system serially connects the two regenerative heat exchangers for regeneration without the bulk associated with air-to-air heat exchange. The liquid circulatory system may also provide heat transport to a remote sink heat exchanger and from a remote load as well as heat exchange within the sink heat exchanger and load for enhanced compactness and efficiency.

  17. The potential of a new air cleaner to reduce airborne microorganisms in pig house air: preliminary results.

    PubMed

    Schulz, Jochen; Bao, Endong; Clauss, Marcus; Hartung, Jörg

    2013-01-01

    There is a need for technical solutions to reduce the concentrations of bioaerosols in the air and in the exhaust air of livestock buildings. A prototype of an air washer combined with a UV-irradiation system was positioned in a commercial pig fattening unit to test its efficiency of reducing culturable airborne microorganisms. No significant reduction in airborne bacteria and fungi was observed when untreated air passed through the device. However, when the air washer or the UV-irradiation system was activated, the concentrations of mesophilic aerobic bacteria, methicillin resistant Staphylococcus aureus and mesophilic aerotolerant cocci were reduced significantly (p < 0.01). Washing the air reduced bacteria by 84 to 96% and the relative reduction due to UV-irradiation ranged between 55 and 90%. The highest relative reduction in airborne bacteria (90 to 99%) was detected when the air washer and the UV-irradiation systems were in simultaneous operation. The concentration of total airborne fungi was reduced significantly (p < 0.05) only when the air was washed and UV-irradiated. Although these preliminary results provided significant and comprehensible findings, long-term studies are required to assess the efficiency of the device in more detail.The combination of air washing and UV-irradiation seem to be a useful technique for abating airborne microorganisms within or emitting from piggery buildings. However, some technical problems remain, such as the deposition of particulate matter on the surface of UV-irradiators and the consumption of fresh water by the air washer. These issues must be resolved before the system may be implemented for general practice. PMID:23540197

  18. Field performance test of an air-cleaner with photocatalysis-plasma synergistic reactors for practical and long-term use.

    PubMed

    Ochiai, Tsuyoshi; Ichihashi, Erina; Nishida, Naoki; Machida, Tadashi; Uchida, Yoshitsugu; Hayashi, Yuji; Morito, Yuko; Fujishima, Akira

    2014-10-29

    A practical and long-term usable air-cleaner based on the synergy of photocatalysis and plasma treatments has been developed. A field test of the air-cleaner was carried out in an office smoking room. The results were compared to previously reported laboratory test results. Even after a treatment of 12,000 cigarettes-worth of tobacco smoke, the air-cleaner maintained high-level air-purification activity (98.9% ± 0.1% and 88% ± 1% removal of the total suspended particulate (TSP) and total volatile organic compound (TVOC) concentrations, respectively) at single-pass conditions. Although the removal ratio of TSP concentrations was 98.6% ± 0.2%, the ratio of TVOC concentrations was 43.8% after a treatment of 21,900 cigarettes-worth of tobacco smoke in the field test. These results indicate the importance of suitable maintenance of the reactors in the air-cleaner during field use.

  19. Tractor-Maintenance: Operation & Daily Care [and] Servicing Air Cleaner & Lubrication. Student Materials. V. A. III. [V-C-1 through V-C-4].

    ERIC Educational Resources Information Center

    Texas A and M Univ., College Station. Vocational Instructional Services.

    Designed for use by students in vocational agricultural classes, this manual deals with tractor maintenance. Operation and daily care are the topics of the first section. Safety is also covered. In the final part of the manual, servicing the air cleaner and lubricating the engine are discussed. Both sections conclude with a quiz. (PLB)

  20. Improving Vacuum Cleaners

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Under a Space Act Agreement between the Kirby company and Lewis Research Center, NASA technology was applied to a commercial vacuum cleaner product line. Kirby engineers were interested in advanced operational concepts, such as particle flow behavior and vibration, critical factors to improve vacuum cleaner performance. An evaluation of the company 1994 home care system, the Kirby G4, led to the refinement of the new G5 and future models. Under the cooperative agreement, Kirby had access to Lewis' holography equipment, which added insight into how long a vacuum cleaner fan would perform, as well as advanced computer software that can simulate the flow of air through fans. The collaboration resulted in several successes including fan blade redesign and continuing dialogue on how to improve air-flow traits in various nozzle designs.

  1. Driving Students and Parents to Cleaner Air: An Interview with Michelle Waters

    ERIC Educational Resources Information Center

    Curriculum Review, 2006

    2006-01-01

    After spending three years as a kindergarten teacher and one as a reading specialist, Michelle Waters recently became the education outreach coordinator for the Georgia-based Clean Air Campaign. In that role, she has helped roll out a comprehensive Better Air Schools initiative to 20 Atlanta-area elementary schools. The program includes a…

  2. The transfer of carbon fibers through a commercial aircraft water separator and air cleaner

    NASA Technical Reports Server (NTRS)

    Meyers, J. A.

    1979-01-01

    The fraction of carbon fibers passing through a water separator and an air filter was determined in order to estimate the proportion of fibers outside a closed aircraft that are transmitted to the electronics through the air conditioning system. When both devices were used together and only fibers 3 mm or larger were considered, a transfer function of .001 was obtained.

  3. Effectiveness of auxiliary air cleaners in reducing ETS components in offices

    SciTech Connect

    Pierce, W.M.; Janczewski, J.N.; Roethlisberger, B.; Pelton, M.; Kunstel, K.

    1996-11-01

    A field study was conducted to evaluate the effectiveness of several auxiliary air cleaning services in reducing components of environmental tobacco smoke (ETS) within a designated smoking lounge and ambient areas in an office suite. Monitoring was performed for the ETS components nicotine, respirable particulate and carbon monoxide. Nicotine and RSP samples were collected in a smoking lounge for two eight-hour periods for each of the following conditions: (1) no smoking in the office suite with no air cleaning devices operating; (2) smoking in the smoking lounge with no clean air devices operating; and (3) smoking in the smoking lounge with one of four air cleaning devices operating. Eight-hour general area and personal samples were also collected to determine levels of nicotine and RSP in ambient, non-smoking areas. Continuous monitoring, with one minute averaging, was performed for carbon monoxide using a direct reading air quality monitor.

  4. Effects on well-being of investing in cleaner air in India.

    PubMed

    Sanderson, Warren; Striessnig, Erich; Schöpp, Wolfgang; Amann, Markus

    2013-01-01

    Over the past decade, India has experienced rapid economic growth along with increases in levels of air pollution. Our goal is to examine how alternative policies for air pollution abatement affect well-being there. In particular, we estimate the effects of policies to reduce the levels of ambient fine particulates (PM2.5), which are especially harmful to human health, on well-being, quantified using the United Nations' human development index (HDI). Two of the three dimensions of this index are based on gross domestic product (GDP) per capita and life expectancy. Our approach allows reductions in PM2.5 to affect both of them. In particular, economic growth is affected negatively through the costs of the additional pollution control measures and positively through the increased productivity of the population. We consider three scenarios of PM2.5 abatement, corresponding to no further control, current Indian legislation, and current European legislation. The overall effect in both control scenarios is that growth in GDP is virtually unaffected relative to the case of no further controls, life expectancy is higher, and well-being, as measured by the HDI, is improved. In India, air pollution abatement investments clearly improve well-being.

  5. Benefits and technological challenges in the implementation of TiO2-based ultraviolet photocatalytic oxidation (UVPCO) air cleaners

    SciTech Connect

    Hodgson, Al; Destaillats, Hugo; Hotchi, Toshifumi; Fisk, William J.

    2008-10-01

    Heating, ventilating, and cooling classrooms in California consume substantial electrical energy. Indoor air quality (IAQ) in classrooms affects student health and performance. In addition to airborne pollutants that are emitted directly by indoor sources and those generated outdoors, secondary pollutants can be formed indoors by chemical reaction of ozone with other chemicals and materials. Filters are used in nearly all classroom heating, ventilation and air-conditioning (HVAC) systems to maintain energy-efficient HVAC performance and improve indoor air quality; however, recent evidence indicates that ozone reactions with filters may, in fact, be a source of secondary pollutants. This project quantitatively evaluated ozone deposition in HVAC filters and byproduct formation, and provided a preliminary assessment of the extent to which filter systems are degrading indoor air quality. The preliminary information obtained will contribute to the design of subsequent research efforts and the identification of energy efficient solutions that improve indoor air quality in classrooms and the health and performance of students.

  6. Development of a Modified Vacuum Cleaner for Lunar Surface Systems

    NASA Technical Reports Server (NTRS)

    Toon, Katherine P.; Lee, Steve A.; Edgerly, Rachel D.

    2009-01-01

    The National Aeronautics and Space Administration (NASA) mission to expand space exploration will return humans to the Moon with the goal of maintaining a long-term presence. One challenge that NASA will face returning to the Moon is managing the lunar regolith found on the Moon's surface, which will collect on extravehicular activity (EVA) suits and other equipment. Based on the Apollo experience, the issues astronauts encountered with lunar regolith included eye/lung irritation, and various hardware failures (seals, screw threads, electrical connectors and fabric contamination), which were all related to inadequate lunar regolith mitigation. A vacuum cleaner capable of detaching, transferring, and efficiently capturing lunar regolith has been proposed as a method to mitigate the lunar regolith problem in the habitable environment on lunar surface. In order to develop this vacuum, a modified "off-the-shelf" vacuum cleaner has been used to determine detachment efficiency, vacuum requirements, and optimal cleaning techniques to ensure efficient dust removal in habitable lunar surfaces, EVA spacesuits, and air exchange volume. During the initial development of the Lunar Surface System vacuum cleaner, systematic testing was performed with varying flow rates on multiple surfaces (fabrics and metallics), atmospheric (14.7 psia) and reduced pressures (10.2 and 8.3 psia), different vacuum tool attachments, and several vacuum cleaning techniques to determine the performance requirements for the vacuum cleaner. The data recorded during testing was evaluated by calculating percent removal, relative to the retained simulant on the tested surface. In addition, Scanning Electron Microscopy (SEM) imaging was used to determine particle size distribution retained on the surface. The scope of this paper is to explain the initial phase of vacuum cleaner development, including historical Apollo mission data, current state-of-the-art vacuum cleaner technology, and vacuum cleaner

  7. Development of a Modified Vacuum Cleaner for Lunar Surface Systems

    NASA Technical Reports Server (NTRS)

    Toon, Katherine P.; Lee, Steve A.; Edgerly, Rachel D.

    2010-01-01

    The National Aeronautics and Space Administration (NASA) mission to expand space exploration will return humans to the Moon with the goal of maintaining a long-term presence. One challenge that NASA will face returning to the Moon is managing the lunar regolith found on the Moon's surface, which will collect on extravehicular activity (EVA) suits and other equipment. Based on the Apollo experience, the issues astronauts encountered with lunar regolith included eye/lung irritation, and various hardware failures (seals, screw threads, electrical connectors and fabric contamination), which were all related to inadequate lunar regolith mitigation. A vacuum cleaner capable of detaching, transferring, and efficiently capturing lunar regolith has been proposed as a method to mitigate the lunar regolith problem in the habitable environment on lunar surface. In order to develop this vacuum, a modified "off-the-shelf' vacuum cleaner will be used to determine detachment efficiency, vacuum requirements, and optimal cleaning techniques to ensure efficient dust removal in habitable lunar surfaces, EVA spacesuits, and air exchange volume. During the initial development of the Lunar Surface System vacuum cleaner, systematic testing was performed with varying flow rates on multiple surfaces (fabrics and metallics), atmospheric (14.7 psia) and reduced pressures (10.2 and 8.3 psia), different vacuum tool attachments, and several vacuum cleaning techniques in order to determine the performance requirements for the vacuum cleaner. The data recorded during testing was evaluated by calculating particulate removal, relative to the retained simulant on the tested surface. In addition, optical microscopy was used to determine particle size distribution retained on the surface. The scope of this paper is to explain the initial phase of vacuum cleaner development, including historical Apollo mission data, current state-of-the-art vacuum cleaner technology, and vacuum cleaner testing that has

  8. High Energy Efficiency Air Conditioning

    SciTech Connect

    Edward McCullough; Patrick Dhooge; Jonathan Nimitz

    2003-12-31

    This project determined the performance of a new high efficiency refrigerant, Ikon B, in a residential air conditioner designed to use R-22. The refrigerant R-22, used in residential and small commercial air conditioners, is being phased out of production in developed countries beginning this year because of concerns regarding its ozone depletion potential. Although a replacement refrigerant, R-410A, is available, it operates at much higher pressure than R-22 and requires new equipment. R-22 air conditioners will continue to be in use for many years to come. Air conditioning is a large part of expensive summer peak power use in many parts of the U.S. Previous testing and computer simulations of Ikon B indicated that it would have 20 - 25% higher coefficient of performance (COP, the amount of cooling obtained per energy used) than R-22 in an air-cooled air conditioner. In this project, a typical new R-22 residential air conditioner was obtained, installed in a large environmental chamber, instrumented, and run both with its original charge of R-22 and then with Ikon B. In the environmental chamber, controlled temperature and humidity could be maintained to obtain repeatable and comparable energy use results. Tests with Ikon B included runs with and without a power controller, and an extended run for several months with subsequent analyses to check compatibility of Ikon B with the air conditioner materials and lubricant. Baseline energy use of the air conditioner with its original R-22 charge was measured at 90 deg F and 100 deg F. After changeover to Ikon B and a larger expansion orifice, energy use was measured at 90 deg F and 100 deg F. Ikon B proved to have about 19% higher COP at 90 deg F and about 26% higher COP at 100 deg F versus R-22. Ikon B had about 20% lower cooling capacity at 90 deg F and about 17% lower cooling capacity at 100 deg F versus R-22 in this system. All results over multiple runs were within 1% relative standard deviation (RSD). All of these

  9. High Efficiency Room Air Conditioner

    SciTech Connect

    Bansal, Pradeep

    2015-01-01

    This project was undertaken as a CRADA project between UT-Battelle and Geberal Electric Company and was funded by Department of Energy to design and develop of a high efficiency room air conditioner. A number of novel elements were investigated to improve the energy efficiency of a state-of-the-art WAC with base capacity of 10,000 BTU/h. One of the major modifications was made by downgrading its capacity from 10,000 BTU/hr to 8,000 BTU/hr by replacing the original compressor with a lower capacity (8,000 BTU/hr) but high efficiency compressor having an EER of 9.7 as compared with 9.3 of the original compressor. However, all heat exchangers from the original unit were retained to provide higher EER. The other subsequent major modifications included- (i) the AC fan motor was replaced by a brushless high efficiency ECM motor along with its fan housing, (ii) the capillary tube was replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and (iii) the unit was tested with a drop-in environmentally friendly binary mixture of R32 (90% molar concentration)/R125 (10% molar concentration). The WAC was tested in the environmental chambers at ORNL as per the design rating conditions of AHAM/ASHRAE (Outdoor- 95F and 40%RH, Indoor- 80F, 51.5%RH). All these modifications resulted in enhancing the EER of the WAC by up to 25%.

  10. Quantification of emission reduction potentials of primary air pollutants from residential solid fuel combustion by adopting cleaner fuels in China.

    PubMed

    Shen, Guofeng

    2015-11-01

    Residential low efficient fuel burning is a major source of many air pollutants produced during incomplete combustions, and household air pollution has been identified as one of the top environmental risk factors. Here we compiled literature-reported emission factors of pollutants including carbon monoxide (CO), total suspended particles (TSPs), PM2.5, organic carbon (OC), elemental carbon (EC) and polycyclic aromatic hydrocarbons (PAHs) for different household energy sources, and quantified the potential for emission reduction by clean fuel adoption. The burning of crop straws, firewood and coal chunks in residential stoves had high emissions per unit fuel mass but lower thermal efficiencies, resulting in high levels of pollution emissions per unit of useful energy, whereas pelletized biofuels and coal briquettes had lower pollutant emissions and higher thermal efficiencies. Briquetting coal may lead to 82%-88% CO, 74%-99% TSP, 73%-76% PM2.5, 64%-98% OC, 92%-99% EC and 80%-83% PAH reductions compared to raw chunk coal. Biomass pelletizing technology would achieve 88%-97% CO, 73%-87% TSP, 79%-88% PM2.5, 94%-96% OC, 91%-99% EC and 63%-96% PAH reduction compared to biomass burning. The adoption of gas fuels (i.e., liquid petroleum gas, natural gas) would achieve significant pollutant reduction, nearly 96% for targeted pollutants. The reduction is related not only to fuel change, but also to the usage of high efficiency stoves.

  11. Efficient one-day sampling of mechanical job exposure data--a study based on upper trapezius activity in cleaners and office workers.

    PubMed

    Mathiassen, Svend Erik; Burdorf, Alex; van der Beek, Allard J; Hansson, Gert-Ake

    2003-01-01

    This ergonomics exposure assessment study compared the efficiency of eight 1-day-only strategies, that is, the relationship between the number of data collected per subject and the precision of the resulting mean exposure estimate. Whole-day electromyographic recordings from the right upper trapezius muscle in 24 cleaners and 23 office workers were processed to give minute-by-minute values of gap time and jerk time-parameters representing the level and frequency dimensions of muscle activation, respectively. On-site observations provided data on time spent in each of eight exhaustive task categories in the job, seven of which were associated with activities during work, and the last comprising breaks. On average, sampling at fixed intervals without regard to tasks doubled efficiency as compared with random sampling, which in turn was several times as efficient as consecutive sampling. Stratified sampling according to the two broad categories, work and breaks, increased efficiency for random and fixed-interval sampling, but the gain was distinct only among cleaners (about 20%). The commonly used strategy in ergonomic studies of sampling consecutively for short periods within tasks was highly inefficient. Further classification of work into the seven subcategories resulted in marginal additional increases in efficiency; on average less than 2%. A decision algorithm is given for determining appropriate sampling strategies in different types of jobs. PMID:12688844

  12. A pilot study of energy efficient air cleaning for ozone

    SciTech Connect

    Gundel, Lara A.; Sullivan, Douglas P.; Katsapov, Gregory Y.; Fisk, William J.

    2002-11-01

    A laboratory pilot study has been undertaken with the material that showed the most promise (high capacity and low pressure drop) based on the literature review and associated calculations. The best-performing air cleaner was a commercially available pleated filter that contained a thin layer of small activated carbon particles between two sheets of non-woven fibrous webbing. We will refer to this unit as the ''ozone filter'' although it is marketed for removal of volatile organic compounds (VOCs) from automobile passenger compartments. This pilot study strongly suggests that ozone air cleaning can be practical in commercial air handling systems; however, further tests are needed to assess air cleaner performance under a wider range of conditions.

  13. Precision aqueous cleaner for RSRM

    NASA Technical Reports Server (NTRS)

    Hutchens, D. E.; Keen, J. M.; Doan, P. A.; Deweese, C. D.; Burns, H. D., Jr.; Vickers, J. H.

    1993-01-01

    Chlorinated solvents such as freon and 1,1,1 trichloroethane (TCA) are both environmental and physiological hazards which deplete stratospheric ozone. These chemicals are the primary degreasing solvents (vapor, vat, and hand operations) in redesigned solid rocket motor (RSRM) manufacturing. Due to the mandates of the Clean Air Act, substitutes must be identified for RSRM cleaning processes. The initial phase of laboratory testing identified candidate cleaners to replace 1,1,1 trichloroethane for cleaning, potentially reducing annual TCA consumption by 800,000 lbs. This paper describes RSRM testing which elucidated the effects of several interdependent variable including: definition of surface cleanliness criteria, validation of cleaning power of new candidates, the effect of immersion cleaning versus spray cleaning on cleaning, any effect of the cleaner and/or inhibitor upon bondline aging, and compatibility of the cleaners with nonmetallic tooling and processing materials.

  14. Performance of a Pin Cylinder Lint Cleaner

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Saw-type lint cleaners are efficient cleaners, but their aggressive nature also causes more fiber damage and wastage. As the U. S. cotton market shifts to overseas where customers are interested in longer fiber with fewer neps and fiber damage, there was a renewed interest to re-evaluate the perfor...

  15. Health effects of tank cleaners.

    PubMed

    Lillienberg, L; Högstedt, B; Järvholm, B; Nilson, L

    1992-06-01

    A total of 29 tank cleaners and 31 referent controls participated in the study. In most cases, the tank cleaners were employed in small companies, usually specialized subcontractors such as firms only working in refineries cleaning oil tanks and handling oil spills. The air concentrations of hydrocarbons (HCs) in tanks containing residuals from heavy fuel oil were generally low, unless the oil was still warm. Addition of light fuel oil to facilitate the cleaning of tanks containing viscous, heavy fuel oils resulted in total airborne HC levels of 1000-1500 mg/m3. High levels of HC were measured in tanks with low-boiling petroleum fractions (naphtha and light fuel oils) of 1000-2600 mg/m3 (maximum). Today, most cleaners use air-supplied respirators or air-purifying respirator cartridges inside tanks with petroleum products or other chemicals. The exception is small firms handling fuel oils for heating purposes where only 50% of the workers use protective equipment regularly; the other workers only occasionally use protective equipment even if the air concentrations of HC are high. Protective equipment is rarely used in small, domestic tanks. Measurements of heart rate showed that tank cleaning is, at times, a highly strenuous job. No differences between tank cleaners and controls were found with respect to spirometry, liver enzymes, or frequency of micronuclei. Acute intoxications were not frequently reported in this group. However, this investigation may underestimate the true risk, as it is a cross-sectional study that found that exposures were highly variable, both quantitatively and qualitatively. In many cases, the tank cleaners knew very little about the potential hazards or the proper use of protective equipment.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1605110

  16. Qualification of environmentally friendly cleaners

    SciTech Connect

    De Marquis, G.; Lopez, E.P.

    1995-05-01

    Sandia National Laboratories (SNL) has traditionally used chlorinated and fluorinated organic solvents for general degreasing applications. Many of these solvents have been labeled by the Federal Government as ozone depleting chemicals and as toxic and/or suspected carcinogens. As a result, these solvents will no longer be recommended for use within the DOE weapons complex. There are three major classes of materials that are of concern for cleaning: organics, metals and ceramics. Each of these materials has its own special cleaning problems. Solvents that were used in the past, such as 1,1,1-trichloroethane (TCA) and trichloroethylene (TCE), were extremely efficient at removing everything from oils and greases to salts without leaving corrosive residues or permanently absorbing into the materials. These traditional degreasing solvents were essentially ``all-inone`` cleaners: quick, reliable, and easy to use. Unfortunately, a ``drop-in`` cleaner for such a wide variety of materials and contaminants will probably never be identified. So far, it has been difficult to identify environmentally conscious cleaners that clean as well as TCE and TCA. Most alternative cleaners require more volume to do the job, and also require longer exposure to get the job done. With these things in mind, we are hoping to identify and qualify new cleaners that will take care of general classes of materials.

  17. Industrial Compressed Air System Energy Efficiency Guidebook.

    SciTech Connect

    United States. Bonneville Power Administration.

    1993-12-01

    Energy efficient design, operation and maintenance of compressed air systems in industrial plants can provide substantial reductions in electric power and other operational costs. This guidebook will help identify cost effective, energy efficiency opportunities in compressed air system design, re-design, operation and maintenance. The guidebook provides: (1) a broad overview of industrial compressed air systems, (2) methods for estimating compressed air consumption and projected air savings, (3) a description of applicable, generic energy conservation measures, and, (4) a review of some compressed air system demonstration projects that have taken place over the last two years. The primary audience for this guidebook includes plant maintenance supervisors, plant engineers, plant managers and others interested in energy management of industrial compressed air systems.

  18. Filter collection efficiency and growth of microorganisms on filters loaded with outdoor air

    SciTech Connect

    Kemp, S.J. |; Kuehn, T.H.; Pui, D.Y.H.; Vesley, D.; Streifel, A.J.

    1995-08-01

    A laboratory setup was used to challenge a glass fiber media filter, a polymer fiber media filter, and a two-stage electrostatic precipitator (electronic air cleaner) with 100% ambient outside air for one year. Over the year, fractional efficiency measurements were made as well as microbial sampling to determine filter effectiveness on ambient viable bioaerosols. Both of the media filters demonstrated greater than 90% effectiveness on fungi and bacteria bioaerosols. The electrostatic precipitator demonstrated initial efficiency of 95% or greater, which decreased over time as the device was overloaded. Normal maintenance of the electrostatic precipitator was minimized in an effort to create conditions favorable to microbial growth. Over the span of the year, no observable microbial growth took place on any of the filters. Subsequent tests on the loaded filters, however, showed that observable microbial growth occurred within a month of continuous exposure to 90% relative humidity.

  19. Managing air to improve combustion efficiency

    SciTech Connect

    Storm, R.F.; Storm, S.K.; Hall, S.G.

    2007-10-15

    Managing the air flow first and then the fuel flow can obtain the best combustion results possible given the constraints of the boiler design. A case study for a typical 500 MW pulverised coal boiler is given where a set of best practices to measure, balance and control furnace inputs to achieve higher combustion efficiencies and lower NOx emissions is applied. 10 figs.

  20. Metal cleaner poisoning

    MedlinePlus

    Metal cleaners contain organic compounds called hydrocarbons, including: 1,2-butylene oxide Boric acid Cocoyl sarcosine Dicarboxylic fatty acid Dimethoxymethane Dodecanedioic acid N-propyl bromide Sodium hydroxide T-butanol

  1. Swimming pool cleaner poisoning

    MedlinePlus

    ... or breathes in its fumes. These cleaners contain chlorine and acids. Chlorine is more likely than the acids to cause ... are: Bromine Calcium chloride Calcium hypochlorite Chelated copper Chlorine Soda ash Sodium bicarbonate Various mild acids

  2. Decontaminating Solar Wind Samples with the Genesis Ultra-Pure Water Megasonic Wafer Spin Cleaner

    NASA Astrophysics Data System (ADS)

    Calaway, M. J.; Rodriguez, M. C.; Allton, J. H.; Stansbery, E. K.

    2009-03-01

    The cleaning efficiency of the Genesis Ultra-pure Water Megasonic Wafer Spin Cleaner will be presented. Results show the effectiveness of the new cleaner removing particle contamination from Genesis silicon wafers implanted with solar wind.

  3. High efficiency novel window air conditioner

    SciTech Connect

    Bansal, Pradeep

    2015-01-01

    This paper presents the technical development of a high efficiency window air conditioner. In order to achieve higher energy efficiency ratio (EER), the original capacity of the R410A unit was downgraded by replacing the original compressor with a lower capacity but higher EER compressor, while all heat exchangers and the chassis from the original unit were retained. The other subsequent major modifications included – the AC fan motor being replaced with a brushless high efficiency electronically commuted motor (ECM) motor, the capillary tube being replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and R410A being replaced with drop-in environmentally friendly binary mixture of R32 (85% molar concentration)/R125 (15% molar concentration). All these modifications resulted in significant EER enhancement of the modified unit.

  4. High efficiency novel window air conditioner

    DOE PAGES

    Bansal, Pradeep

    2015-01-01

    This paper presents the technical development of a high efficiency window air conditioner. In order to achieve higher energy efficiency ratio (EER), the original capacity of the R410A unit was downgraded by replacing the original compressor with a lower capacity but higher EER compressor, while all heat exchangers and the chassis from the original unit were retained. The other subsequent major modifications included – the AC fan motor being replaced with a brushless high efficiency electronically commuted motor (ECM) motor, the capillary tube being replaced with a needle valve to better control the refrigerant flow and refrigerant set points, andmore » R410A being replaced with drop-in environmentally friendly binary mixture of R32 (85% molar concentration)/R125 (15% molar concentration). All these modifications resulted in significant EER enhancement of the modified unit.« less

  5. Air transportation energy efficiency - Alternatives and implications

    NASA Technical Reports Server (NTRS)

    Williams, L. J.

    1976-01-01

    Results from recent studies of air transportation energy efficiency alternatives are discussed, along with some of the implications of these alternatives. The fuel-saving alternatives considered include aircraft operation, aircraft modification, derivative aircraft, and new aircraft. In the near-term, energy efficiency improvements should be possible through small improvements in fuel-saving flight procedures, higher density seating, and higher load factors. Additional small near-term improvements could be obtained through aircraft modifications, such as the relatively inexpensive drag reduction modifications. Derivatives of existing aircraft could meet the requirements for new aircraft and provide energy improvements until advanced technology is available to justify the cost of a completely new design. In order to obtain significant improvements in energy efficiency, new aircraft must truly exploit advanced technology in such areas as aerodynamics, composite structures, active controls, and advanced propulsion.

  6. Explosion proofing the ``explosion proof`` vacuum cleaner

    SciTech Connect

    Jones, R.D.; Chen, K.C.; Holmes, S.W.

    1995-07-01

    Because of the low humidity environments required in the fabrication of nuclear explosives, assembly technicians can be charged to tens of kilovolts while operating, for example, compressed air, venturi-type, `explosion proof` vacuum cleaners. Nuclear explosives must be isolated from all sources of, and return paths for, AC power and from any part of the lightning protection system. This requirement precludes the use of static ground conductors to drain any charge accumulations. Accordingly, an experimental study of the basic charging mechanisms associated with vacuum operations were identified, the charge generation efficacies of various commercial cleaners were established, and a simple method for neutralizing the charge was devised.

  7. 78 FR 44947 - Request for Nominations for 2014 Clean Air Excellence Awards Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-25

    ... progress in achieving cleaner air. The CAEAP is open to both public and private entities. Entries are... Innovations; and (5) Transportation Efficiency Innovations. There are also two special awards categories:...

  8. SUBMERGED GRAVEL SCRUBBER DEMONSTRATION AS A PASSIVE AIR CLEANER FOR CONTAINMENT VENTING AND PURGING WITH SODIUM AEROSOLS -- CSTF TESTS AC7 - AC10

    SciTech Connect

    HILLIARD, R K.; MCCORMACK, J D.; POSTMA, A K.

    1981-11-01

    Four large-scale air cleaning tests (AC7 - AC10) were performed in the Containment Systems Test Facility (CS'lF) to demonstrate the performance of a Submerged Gravel Scrubber for cleaning the effluent gas from a vented and purged breeder reactor containment vessel. The test article, comprised of a Submerged Gravel Scrubber (SGS) followed by a high efficiency fiber demister, had a design gas flow rate of 0.47 m{sup 3}/s (1000 ft{sup 3}/min) at a pressure drop of 9.0 kPa (36 in. H{sub 2}O). The test aerosol was sodium oxide, sodium hydroxide, or sodium carbonate generated in the 850-m{sup 3} CSTF vessel by continuously spraying sodium into the air-filled vessel while adding steam or carbon dioxide. Approximately 4500 kg (10,000 lb) of sodium was sprayed over a total period of 100 h during the tests. The SGS/Demister system was shown to be highly efficient (removing ~99.98% of the entering sodium aerosol mass), had a high mass loading capacity, and operated in a passive manner, with no electrical requirement. Models for predicting aerosol capture, gas cooling, and pressure drop are developed and compared with experimental results.

  9. Materials compatibility issues associated with aqueous alkaline cleaners

    SciTech Connect

    Lopez, E.P.; Montoya, M.G.

    1996-04-01

    As part of the Environmentally Conscious Manufacturing (ECM) technology, and in support of various mechanical assembly applications, several aqueous alkaline cleaners were studied as potential candidates for cleaning mechanical piece parts. Historically, ozone depleting and hazardous chlorinated cleaners have been used to degrease mechanical assemblies. In an effort to replace these chemicals, several cleaning processes, including aqueous alkaline cleaners, were screened as potential candidates using a variety of criteria, including aqueous alkaline cleaners, were screened as potential candidates using a variety of criteria, including: cleaning efficiency, materials compatibility, etch rate, corrosion, immersion tests, temperature/humidity exposure, and an exposure to a simulated indoor industrial environment. Cleaning efficiency was determined using visual examination, Auger electron spectroscopy, X-ray photoelectron spectroscopy, MESERAN, and goniometer/contact angle measurements. Several cleaners were identified as potential alternatives based solely on the cleaning results. Some of the cleaners, however, left undesirable residues. This paper will focus on materials compatibility issues of these aqueous cleaners after immersion tests, an etch rate study, and exposures to temperature/humidity and a standard industrial environment.

  10. EER, COP, and the Second Law Efficiency for Air Conditioners

    ERIC Educational Resources Information Center

    Leff, Harvey S.; Teeters, William D.

    1978-01-01

    Describes the relationship existing between coefficient of performance (COP) and energy efficiency ratio (EER) in air conditioning units and introduces new efficiency parameters measured relative to the energy extracted from the primary energy source. (SL)

  11. Issue Backgrounder : Energy Efficient New Homes and Indoor Air Pollutants.

    SciTech Connect

    United States. Bonneville Power Administration.

    1985-07-01

    This booklet discusses what indoor air pollution is and how it can affect your health. It describes how energy-efficient new homes can affect indoor air quality. It also describes features that can help ensure clean indoor air, and tells how to detect and control indoor pollutants commonly found in homes.

  12. Cleaning efficacy of high-efficiency particulate air-filtered vacuuming and "dry steam" cleaning on carpet.

    PubMed

    Yiin, Lih-Ming; Yu, Chang Ho; Ashley, Peter; Rhoads, George

    2008-02-01

    Previous studies for lead exposure reduction have indicated the difficulty in reducing surface contamination of carpets with the use of regular vacuum cleaners. To find a solution, a household vacuum cleaner equipped with a high-efficiency particulate air (HEPA) filter and a dust finder indicator, and a "dry steam" cleaner previously reported effective in reducing dust mite allergens in carpets and mattresses were tested for effectiveness in reducing lead dust in carpets. Fifty homes of lead-exposed children were tested in New Jersey. A selected carpet in the living area of each home was tested with two interventions: half was cleaned by HEPA vacuuming twice (VAC-VAC) and the other half by dry steaming between the two HEPA vacuumings (VAC-DSC-VAC). Wipe and vacuum samples, representing surface dust and total dust collections, respectively, were taken before and after cleaning. The wipe and vacuum sample data indicated that both cleaning methods substantially reduced dust lead levels (p < 0.001). The mean percent reductions in lead loading were approximately 29% and 40% for the VAC-VAC and VAC-DSC-VAC interventions, respectively. The difference between the two postcleaning levels was statistically significant by wipe sampling (p = 0.038) but was marginally insignificant by vacuum sampling (p = 0.072). A subset of sample data collected before repeat vacuuming (VAC-DSC) suggested that repeat vacuuming after dry steam cleaning is unnecessary. In summary, slow and steady HEPA vacuuming with the help of a dust finder indicator reduces surface and overall lead dust in carpets, and dry steam cleaning further reduces surface lead contamination as compared with HEPA vacuuming alone.

  13. Cleaning efficacy of high-efficiency particulate air-filtered vacuuming and "dry steam" cleaning on carpet.

    PubMed

    Yiin, Lih-Ming; Yu, Chang Ho; Ashley, Peter; Rhoads, George

    2008-02-01

    Previous studies for lead exposure reduction have indicated the difficulty in reducing surface contamination of carpets with the use of regular vacuum cleaners. To find a solution, a household vacuum cleaner equipped with a high-efficiency particulate air (HEPA) filter and a dust finder indicator, and a "dry steam" cleaner previously reported effective in reducing dust mite allergens in carpets and mattresses were tested for effectiveness in reducing lead dust in carpets. Fifty homes of lead-exposed children were tested in New Jersey. A selected carpet in the living area of each home was tested with two interventions: half was cleaned by HEPA vacuuming twice (VAC-VAC) and the other half by dry steaming between the two HEPA vacuumings (VAC-DSC-VAC). Wipe and vacuum samples, representing surface dust and total dust collections, respectively, were taken before and after cleaning. The wipe and vacuum sample data indicated that both cleaning methods substantially reduced dust lead levels (p < 0.001). The mean percent reductions in lead loading were approximately 29% and 40% for the VAC-VAC and VAC-DSC-VAC interventions, respectively. The difference between the two postcleaning levels was statistically significant by wipe sampling (p = 0.038) but was marginally insignificant by vacuum sampling (p = 0.072). A subset of sample data collected before repeat vacuuming (VAC-DSC) suggested that repeat vacuuming after dry steam cleaning is unnecessary. In summary, slow and steady HEPA vacuuming with the help of a dust finder indicator reduces surface and overall lead dust in carpets, and dry steam cleaning further reduces surface lead contamination as compared with HEPA vacuuming alone. PMID:18075882

  14. Pellet stove with enhanced air circulation efficiency

    SciTech Connect

    Burke, T.M.; Burke, W.L.

    1992-06-23

    This patent describes a stove for converting fuel to heat. It comprises means defining a fuel storage area; means for pressurizing the fuel storage area, the means comprising a single air blowing means; means defining a combustion area for allowing combustion to take place; vent means for venting air from the combustion area; means defining a heat exchange area adjacent to and in contact with the combustion area for removing heat from the combustion area; and means for conducting pressurized air from the fuel storage area directly to the combustion area and directly to the heat exchange area.

  15. Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems.

    PubMed

    Macintosh, David L; Myatt, Theodore A; Ludwig, Jerry F; Baker, Brian J; Suh, Helen H; Spengler, John D

    2008-11-01

    A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates. PMID:19044163

  16. The general efficiency curve for air propellers

    NASA Technical Reports Server (NTRS)

    Diehl, Walter S

    1924-01-01

    This report presents a formula which may be used to obtain a "general efficiency curve" in addition to the well-known maximum efficiency curve. These two curves, when modified somewhat by experimental data, enable performance calculations to be made without detailed knowledge of the propeller. The curves may also be used to estimate the improvement in efficiency due to reduction gearing, or to judge the performance of a new propeller design.

  17. Supersonic-Spray Cleaner

    NASA Technical Reports Server (NTRS)

    Caimi, Raoul E. B.; Lin, Feng-Nan; Thaxton, Eric A.

    1995-01-01

    Spraying system for cleaning mechanical components uses less liquid and operates at pressures significantly lower. Liquid currently used is water. Designed to replace chlorofluorocarbon (CFC) solvent-based cleaning and cleanliness verification methods. Consists of spray head containing supersonic converging/diverging nozzles, source of gas at regulated pressure, pressurized liquid tank, and various hoses, fittings, valves, and gauges. Parameters of nozzles set so any of large variety of liquids and gases combined in desired ratio and rate of flow. Size and number of nozzles varied so system built in configurations ranging from small hand-held spray heads to large multinozzle cleaners. Also used to verify part adequately cleaned. Runoff liquid from spray directed at part collected. Liquid analyzed for presence of contaminants, and part recleaned if necessary.

  18. Evaluation of Alkaline Cleaner Materials

    NASA Technical Reports Server (NTRS)

    Partz, Earl

    1998-01-01

    Alkaline cleaners used to process aluminum substrates have contained chromium as the corrosion inhibitor. Chromium is a hazardous substance whose use and control are described by environmental laws. Replacement materials that have the characteristics of chromated alkaline cleaners need to be found that address both the cleaning requirements and environmental impacts. This report will review environmentally friendly candidates evaluated as non-chromium alkaline cleaner replacements and methods used to compare those candidates one versus another. The report will also list characteristics used to select candidates based on their declared contents. It will also describe and evaluate methods used to discriminate among the large number of prospective candidates.

  19. Energy Efficiency for Heating, Ventilating, Air-Conditioning Instructors.

    ERIC Educational Resources Information Center

    Scharmann, Larry, Ed.; Lay, Gary, Ed.

    Intended primarily but not solely for use at the postsecondary level, this curriculum guide contains five units on energy efficiency that were designed to be incorporated into an existing program in heating, ventilating, and air-conditioning. The following topics are examined: how energy conservation pays, heating, ventilation, air-conditioning,…

  20. Efficient Conversation: The Talk between Pilots and Air Traffic Controllers.

    ERIC Educational Resources Information Center

    Simmons, James L.

    Two-way radio communications between air traffic controllers using radar on the ground to give airplane pilots instructions are of interest within the developing framework of the sociology of language. The main purpose of air traffic control language is efficient communication to promote flight safety. This study describes the standardized format…

  1. Air Force Achieves Fuel Efficiency through Industry Best Practices

    SciTech Connect

    2012-12-01

    The U.S. Air Force’s Air Mobility Command (AMC) is changing the way it does business. It is saving energy and money through an aircraft fleet fuel-efficiency program inspired by private industry best practices and ideas resulting from the empowered fuel savings culture.

  2. Health-hazard evaluation report HETA 86-005-1679, Dutch Girl Cleaners, Springdale, Ohio

    SciTech Connect

    Burr, G.A.; Todd, W.

    1986-03-01

    An environmental survey at Dutch Girl Cleaners in the Thriftway Mini Mall, Springdale, Ohio, was conducted on October 25, 1985, and air samples collected on October 30, 1985 from the cleaners, an adjacent supermarket and the enclosed pedestrian mall were analyzed for perchloroethylene.

  3. Concentration of tetrachloroethylene in indoor air at a former dry cleaner facility as a function of subsurface contamination: a case study.

    PubMed

    Eklund, Bart M; Simon, Michelle A

    2007-06-01

    A field study was performed to evaluate indoor air concentrations and vapor intrusion (VI) of tetrachloroethylene (PCE) and other chlorinated solvents at a commercial retail site in Dallas, TX. The building is approximately 40 yr old and once housed a dry cleaning operation. Results from an initial site characterization were used to select sampling locations for the VI study. The general approach for evaluating VI was to collect time-integrated canister samples for off-site U.S. Environmental Protection Agency Method TO-15 analyses. PCE and other chlorinated solvents were measured in shallow soil gas, subslab soil-gas, indoor air, and ambient air. The subslab soil gas exhibited relatively high values: PCE < or =2,600,000 parts per billion by volume (ppbv) and trichloroethylene < or =170 ppbv. The attenuation factor, the ratio of indoor air and subslab soil-gas concentrations, was unusually low: approximately 5 x 10(-6) based on the maximum subslab soil-gas concentration of PCE and 1.4 x 10(-5) based on average values.

  4. CONCENTRATION OF TETRACHLOROETHYLENE IN INDOOR AIR AT A FORMER DRY CLEANER FACILITY AS A FUNCTION OF SUBSURFACE CONTAMINATION: A CASE STUDY

    EPA Science Inventory

    A field study was performed to evaluate indoor air concentrations and vapor intrusion (VI) of tetrachloroethylene (PCE) and other chlorinated solvents at a commercial retail site in Dallas, TX. The building is approximately 40 years old and once housed a dry cleaning operation. R...

  5. Air Cleaning Technologies

    PubMed Central

    2005-01-01

    Executive Summary Objective This health technology policy assessment will answer the following questions: When should in-room air cleaners be used? How effective are in-room air cleaners? Are in-room air cleaners that use combined HEPA and UVGI air cleaning technology more effective than those that use HEPA filtration alone? What is the Plasmacluster ion air purifier in the pandemic influenza preparation plan? The experience of severe acute respiratory syndrome (SARS) locally, nationally, and internationally underscored the importance of administrative, environmental, and personal protective infection control measures in health care facilities. In the aftermath of the SARS crisis, there was a need for a clearer understanding of Ontario’s capacity to manage suspected or confirmed cases of airborne infectious diseases. In so doing, the Walker Commission thought that more attention should be paid to the potential use of new technologies such as in-room air cleaning units. It recommended that the Medical Advisory Secretariat of the Ontario Ministry of Health and Long-Term Care evaluate the appropriate use and effectiveness of such new technologies. Accordingly, the Ontario Health Technology Advisory Committee asked the Medical Advisory Secretariat to review the literature on the effectiveness and utility of in-room air cleaners that use high-efficiency particle air (HEPA) filters and ultraviolet germicidal irradiation (UVGI) air cleaning technology. Additionally, the Ontario Health Technology Advisory Committee prioritized a request from the ministry’s Emergency Management Unit to investigate the possible role of the Plasmacluster ion air purifier manufactured by Sharp Electronics Corporation, in the pandemic influenza preparation plan. Clinical Need Airborne transmission of infectious diseases depends in part on the concentration of breathable infectious pathogens (germs) in room air. Infection control is achieved by a combination of administrative, engineering

  6. Coping with Indoor Air Pollution

    MedlinePlus

    ... itself. Household chemical cleaners Use baking soda or vinegar and water as household cleaners. For a job ... after each use by using one-part white vinegar to three-parts water. Let the pieces air- ...

  7. Effect of air flow on tubular solar still efficiency

    PubMed Central

    2013-01-01

    Background An experimental work was reported to estimate the increase in distillate yield for a compound parabolic concentrator-concentric tubular solar still (CPC-CTSS). The CPC dramatically increases the heating of the saline water. A novel idea was proposed to study the characteristic features of CPC for desalination to produce a large quantity of distillate yield. A rectangular basin of dimension 2 m × 0.025 m × 0.02 m was fabricated of copper and was placed at the focus of the CPC. This basin is covered by two cylindrical glass tubes of length 2 m with two different diameters of 0.02 m and 0.03 m. The experimental study was operated with two modes: without and with air flow between inner and outer tubes. The rate of air flow was fixed throughout the experiment at 4.5 m/s. On the basis of performance results, the water collection rate was 1445 ml/day without air flow and 2020 ml/day with air flow and the efficiencies were 16.2% and 18.9%, respectively. Findings The experimental study was operated with two modes: without and with air flow between inner and outer tubes. The rate of air flow was fixed throughout the experiment at 4.5 m/s. Conclusions On the basis of performance results, the water collection rate was 1445 ml/day without air flow and 2020 ml/day with air flow and the efficiencies were 16.2% and 18.9%, respectively. PMID:23587020

  8. Aging Effects of Environmentally-Friendly Cleaners on Adhesive Bond Integrity

    NASA Technical Reports Server (NTRS)

    Biegert, L. L.; Anderson, G. L.; Evans, K. B.; Olsen, B. D.; Weber, B. L.; McCool, A. A. (Technical Monitor)

    2000-01-01

    Because of the 1990 Clean Air Act Amendment many chlorinated solvents are being phased out of use in manufacturing industries. Replacement of the ODC (ozone- depleting chemicals) with less volatile, non-ozone depleting cleaners has been extensively studied over the past nine years at Thiokol Propulsion, Cordant Technologies. Many of the non-ODC cleaners contain compounds that can potentially degrade over time under conditions of high temperature, humidity and exposure to light. The chemical composition of environmentally conditioned cleaners and the subsequent effect on aluminum/amine-cured epoxy bond integrity as measured by Tapered Double Cantilever Beam were evaluated. From this study it is observed that moisture content increases for those cleaners containing polar compounds. Non-volatile residue content increases as stabilizers are depleted and the chemical compound limonene is oxidized. A change in aluminum/ amine-cured epoxy bond fracture toughness is observed as some of these cleaners age with increases in moisture and NVR content.

  9. 7 CFR 2902.30 - Glass cleaners.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Glass cleaners. 2902.30 Section 2902.30 Agriculture... Glass cleaners. (a) Definition. Cleaning products designed specifically for use in cleaning glass... qualifying biobased glass cleaners. By that date, Federal agencies that have the responsibility for...

  10. 7 CFR 2902.30 - Glass cleaners.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Glass cleaners. 2902.30 Section 2902.30 Agriculture... Glass cleaners. (a) Definition. Cleaning products designed specifically for use in cleaning glass... qualifying biobased glass cleaners. By that date, Federal agencies that have the responsibility for...

  11. Robotic Water Blast Cleaner

    NASA Technical Reports Server (NTRS)

    Sharpe, M. H.; Roberts, M. L.; Hill, W. E.; Jackson, C. H.

    1983-01-01

    Water blasting system under development removes hard, dense, extraneous material from surfaces. High pressure pump forces water at supersonic speed through nozzle manipulated by robot. Impact of water blasts away unwanted material from workpiece rotated on air bearing turntable. Designed for removing thermal-protection material, system is adaptable to such industrial processes as cleaning iron or steel castings.

  12. Cleaner Vacuum-Bag Curing

    NASA Technical Reports Server (NTRS)

    Clemons, J. M.; Penn, B. G.; Ledbetter, Frank E., III; Daniels, J. G.

    1987-01-01

    Improvement upon recommended procedures saves time and expense. Autoclave molding in vacuum bag cleaner if adhesive-backed covering placed around caul plate as well as on mold plate. Covering easy to remove after curing and leaves caul plate free of resin deposits.

  13. Determining benefits and costs of improved central air conditioner efficiencies

    SciTech Connect

    Rosenquist, G.; Levok, A.; Chan, P.; McMahon, J.

    2001-01-12

    Economic impacts on individual consumers from possible revisions to U.S. residential-type central air conditioner energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a central air conditioner and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers due to modest increases in efficiency are significant. For an efficiency increase of 20percent over the existing minimum standard (i.e., 12 SEER), 35percent of households with central air conditioners experience significant LCC savings, with an average savings of $453, while 25percent show significant LCC losses, with an average loss of $158 compared to apre-standard LCC average of $5,170. The remainder of the population (40percent) are largely unaffected.

  14. The high efficiency steel filters for nuclear air cleaning

    SciTech Connect

    Bergman, W.; Larsen, G.; Lopez, R.; Williams, K.; Violet, C.

    1990-08-01

    We have, in cooperation with industry, developed high-efficiency filters made from sintered stainless-steel fibers for use in several air-cleaning applications in the nuclear industry. These filters were developed to overcome the failure modes in present high-efficiency particulate air (HEPA) filters. HEPA filters are made from glass paper and glue, and they may fail when they get hot or wet and when they are overpressured. In developing our steel filters, we first evaluated the commercially available stainless-steel filter media made from sintered powder and sintered fiber. The sintered-fiber media performed much better than sintered-powder media, and the best media had the smallest fiber diameter. Using the best media, we then built prototype filters for venting compressed gases and evaluated them in our automated filter tester. 12 refs., 20 figs.

  15. The effect of inlet air vitiation on combustion efficiency

    SciTech Connect

    Zuomin, F.; Yijun, J.

    1985-01-01

    Experimental results of the effect of inlet air vitiation produced by a vitiating preheater on combustion efficiency of a turbojet combustor and a model ramjet combustor are presented in this paper. An empirical correlation and a calculation method based on stirred reactor theory are derived to correct the vitiation effect. Results obtained by means of these two methods are in good agreement with test data.

  16. HEPA (high efficiency particulate air) filter optimization/implementation

    SciTech Connect

    Nenni, J.A.

    1988-02-10

    Prefilters were installed in high efficiency particularly air (HEPA) filter plenums at the Rocky Flats Plant. It was determined that prefiltration systems would extend the life of first-stage HEPA filters and reduce the amount of HEPA filter waste in the transuranic waste category. A remote handling system was designed to remove prefilters without entry into the plenum to reduce secondary waste and decrease exposure to Filter Technicians. 3 figs., 4 tabs.

  17. Magnetic Refrigeration Technology for High Efficiency Air Conditioning

    SciTech Connect

    Boeder, A; Zimm, C

    2006-09-30

    Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate

  18. MTBE: The headache of cleaner air

    SciTech Connect

    Kneiss, J.

    1995-07-01

    Gasoline with methyl tertiary butyl ether (MTBE) has been sold in the United States since 1979, when it was added to fuels as an octane enhancer after lead was phased out of motor fuels. Recently it has been introduced as a means of reducing carbon monoxide emissions during the winter months in targeted US cities. However, there is concern over health complaints including headaches, dizziness and nausea from residents of some areas. These reports have launched an era of assidious research by scientists and public health officials across the country to learn more about MTBE`s short-term and long-term, and possibly carcinogenic, health effects. New research should help weigh the risk of MTBE as a possible carcinogen and the effectiveness of MTBE-blended fuels in reducing carbon monoxide levels. The question is whether, in minimizing one risk, is another risk - however small - being introduced?

  19. California`s cleaner burning gasoline and methyl tertiary butyl ether

    SciTech Connect

    Denton, J.; Mazur, L.

    1995-12-31

    As of June 1, 1996, California is required to use cleaner-burning gasoline to help meet federal ambient air quality standards and reduce ambient air toxics. Cleaner-burning gasoline reduces smog-forming emissions from motor vehicles by 15% and air pollution by over three million pounds per day. This is equivalent to removing 3.5 million cars from California`s roads. To enhance combustion and thus reduce emissions, California cleaner burning gasoline is required to contain 2.0% oxygen by weight. This is achieved by addition of oxygenates, such as methyl tertiary butyl ether (MTBE). Ambient air data of MTBE derived from motor vehicle emissions and refueling activities has been measured in several pilot studies and at 22 urban sites as part of California`s Air Resources Board statewide toxics monitoring network. These activities have only recently been initiated and this paper will describe data collected to date.

  20. Cleaner Energy for Cars

    SciTech Connect

    Cropley, Cecelia

    2013-07-18

    Representing the Center for Catalytic Hydrocarbon Functionalization (CCHF), this document is one of the entries in the Ten Hundred and One Word Challenge. As part of the challenge, the 46 Energy Frontier Research Centers were invited to represent their science in images, cartoons, photos, words and original paintings, but any descriptions or words could only use the 1000 most commonly used words in the English language, with the addition of one word important to each of the EFRCs and the mission of DOE: energy. The mission of CCHF is to develop, validate, and optimize new methods to rearrange the bonds of hydrocarbons, implement enzymatic strategies into synthetic systems, and design optimal environments for catalysts that can be used to reversibly functionalize hydrocarbons, especially for more efficient use of natural gas including low temperature conversion to liquid fuels.

  1. Investigation of key parameters influencing the efficient photocatalytic oxidation of indoor volatile organic compounds (VOCs)

    SciTech Connect

    Quici, Natalia; Kibanova, Daria; Vera, Maria Laura; Choi, Hyeok; Dionysiou, Dionysios D.; Litter, Marta I.; Cervini-Silva, Javiera; Hodgson, Alfred T.; Destaillats, Hugo; Destaillats, Hugo

    2008-06-01

    Photocatalytic oxidation of indoor VOCs has the potential to eliminate pollutants from indoor environments, thus effectively improving and/or maintaining indoor air quality while reducing ventilation energy costs. Design and operation of UV photocatalytic oxidation (UVPCO) air cleaners requires optimization of various parameters to achieve highest pollutant removal efficiencies while avoiding the formation of harmful secondary byproducts and maximizing catalyst lifetime.

  2. Calorimetric measurement of energy of ultrasonic cleaners

    SciTech Connect

    Harding, W.B.

    1994-11-01

    The development of a calorimeter that measured the power within an ultrasonic cleaning tank is presented. The principle involved is explained. Several types of calorimeter that were tested are described. Measurement of the power in an ultrasonic cleaner permits: (1) comparing different ultrasonic cleaners; (2) monitoring the performance of a specific cleaner; (3) measuring the distribution of power in a cleaning tank, and (4) evaluating the effects of process variables on the power.

  3. A novel cleaner production process of citric acid by recycling its treated wastewater.

    PubMed

    Xu, Jian; Su, Xian-Feng; Bao, Jia-Wei; Zhang, Hong-Jian; Zeng, Xin; Tang, Lei; Wang, Ke; Zhang, Jian-Hua; Chen, Xu-Sheng; Mao, Zhong-Gui

    2016-07-01

    In this study, a novel cleaner production process of citric acid was proposed to completely solve the problem of wastewater management in citric acid industry. In the process, wastewater from citric acid fermentation was used to produce methane through anaerobic digestion and then the anaerobic digestion effluent was further treated with air stripping and electrodialysis before recycled as process water for the later citric acid fermentation. This proposed process was performed for 10 batches and the average citric acid production in recycling batches was 142.4±2.1g/L which was comparable to that with tap water (141.6g/L). Anaerobic digestion was also efficient and stable in operation. The average chemical oxygen demand (COD) removal rate was 95.1±1.2% and methane yield approached to 297.7±19.8mL/g TCODremoved. In conclusion, this novel process minimized the wastewater discharge and achieved the cleaner production in citric acid industry.

  4. 7 CFR 3201.30 - Glass cleaners.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 15 2012-01-01 2012-01-01 false Glass cleaners. 3201.30 Section 3201.30 Agriculture... Items § 3201.30 Glass cleaners. (a) Definition. Cleaning products designed specifically for use in cleaning glass surfaces, such as windows, mirrors, car windows, and computer monitors. (b) Minimum...

  5. 7 CFR 3201.30 - Glass cleaners.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Glass cleaners. 3201.30 Section 3201.30 Agriculture... Items § 3201.30 Glass cleaners. (a) Definition. Cleaning products designed specifically for use in cleaning glass surfaces, such as windows, mirrors, car windows, and computer monitors. (b) Minimum...

  6. 7 CFR 3201.30 - Glass cleaners.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Glass cleaners. 3201.30 Section 3201.30 Agriculture... Items § 3201.30 Glass cleaners. (a) Definition. Cleaning products designed specifically for use in cleaning glass surfaces, such as windows, mirrors, car windows, and computer monitors. (b) Minimum...

  7. 7 CFR 3201.45 - Food cleaners.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Food cleaners. 3201.45 Section 3201.45 Agriculture... Items § 3201.45 Food cleaners. (a) Definition. Anti-microbial products designed to clean the outer layer of various food products, such as fruit, vegetables, and meats. (b) Minimum biobased content....

  8. 7 CFR 3201.45 - Food cleaners.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 15 2012-01-01 2012-01-01 false Food cleaners. 3201.45 Section 3201.45 Agriculture... Items § 3201.45 Food cleaners. (a) Definition. Anti-microbial products designed to clean the outer layer of various food products, such as fruit, vegetables, and meats. (b) Minimum biobased content....

  9. 7 CFR 3201.45 - Food cleaners.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Food cleaners. 3201.45 Section 3201.45 Agriculture... Items § 3201.45 Food cleaners. (a) Definition. Anti-microbial products designed to clean the outer layer of various food products, such as fruit, vegetables, and meats. (b) Minimum biobased content....

  10. Chemical Aging of Environmentally Friendly Cleaners

    NASA Technical Reports Server (NTRS)

    Biegert, L. L.; Evans, K. B.; Olsen, B. D.; Weber, B. L.

    2001-01-01

    Use of cleaners in the manufacturing area demands bottles that will hold a sufficient amount of material and allow for easy and controlled dispensing by the operator without contamination or material leaching from the bottle. The manufacturing storage conditions are also a factor that may affect cleaner chemical integrity and its potential to leave a residue on the part. A variety of squeeze bottles stored in mild (72 F, 10% R.H., dark) and harsh (105 F, 50% R.H., fluorescent lighting) conditions were evaluated to determine the effect of environment and bottle exposure on ozone depleting chemicals (ODC) cleaners chemical composition. Low Density Polyethylene (LDPE) bottles were found to be quite permeable to all the cleaners evaluated in this study indicating this bottle type should not be used in the manufacturing area. Fluorinated Polyethylene (FLPE) bottles showed little cleaner loss and change in cleaner chemical composition over time suggesting these bottles would be acceptable for use. Chemical analysis indicates limonene containing cleaners show increased non-volatile residue (NVR) content with storage under harsh conditions. Some cleaners use BHT (butylated hydroxytoluene) as stabilizer and to protect against limonene oxidation. Under harsh conditions, BHT was quickly depleted resulting in higher NVR levels.

  11. 7 CFR 2902.45 - Food cleaners.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Food cleaners. 2902.45 Section 2902.45 Agriculture... Food cleaners. (a) Definition. Anti-microbial products designed to clean the outer layer of various food products, such as fruit, vegetables, and meats. (b) Minimum biobased content. The...

  12. 7 CFR 2902.45 - Food cleaners.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Food cleaners. 2902.45 Section 2902.45 Agriculture... Food cleaners. (a) Definition. Anti-microbial products designed to clean the outer layer of various food products, such as fruit, vegetables, and meats. (b) Minimum biobased content. The...

  13. Multibar sawless lint cleaner: Field testing results

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The Multibar Sawless Lint Cleaner (MBSLC) is a prototype spiked-tooth lint cleaner initially designed to replace the first stage lint cleaning in a cotton gin. Previous studies conducted in the ginning laboratory in Lubbock, Texas, demonstrated improvements in some fiber properties, as well as minim...

  14. GUIDE TO CLEANER TECHNOLOGIES: ALTERNATIVE METAL FINISHES

    EPA Science Inventory

    A cleaner technology is a source reduction or recycle method applied to eliminate or significantly reduce the amount of any hazardous substance, pollutant, or contaminant released to the environment. The emphasis of cleaner technologies is on process changes that can prevent poll...

  15. Influence of the inlet air in efficiency of photocatalytic devices for mineralization of VOCs in air-conditioning installations.

    PubMed

    Jimenez-Relinque, E; Castellote, M

    2014-10-01

    Nowadays, a large proportion of photocatalytic oxidation (PCO) devices are being implemented in heating, ventilation and air-conditioning systems. However, no systematic studies have been carried out regarding the influence of inlet air preconditioning. To analyse the impact of the inlet air-conditions into photocatalytic efficiency, a simulated air-conditioning duct with flowing gas through inside was designed. Isobutylene was chosen as the target VOCs. The concentration in the gas phase was monitored using a photoionization detector. The influence of flow rate, relative humidity and temperature on the VOC removal efficiency was analysed. Experimental results were presented in terms of gas-removal efficiency (η) and clean air delivery rate (CADR) and analysed on a kinetic basis. From them, the weight of each parameter in the global process has been determined, from bigger to smaller contribution, flow>temperature>relative humidity. Also, the relevance of the inlet air conditions has been illustrated in a model room in order to determinate the time necessary to obtain a threshold value accomplishing with enough air quality and the energy consumption of the device. Additionally, the photocatalytic decontamination has been assimilated to the "air exchange rate", a parameter commonly used in indoor air quality studies. The results show that preconditioning of air can improve the efficiency of photocatalytic devices and bring important energy savings.

  16. Chemical Aging of Environmentally Friendly Cleaners

    NASA Technical Reports Server (NTRS)

    Evans, K.; Biegert, L.; Olsen, B.; Weber, B.; McCool, Alex (Technical Monitor)

    2001-01-01

    Use of cleaners in the manufacturing area demands bottles that will hold a sufficient amount of material and allow for easy and controlled dispensing by the operator without contamination or material leaching from the bottle. The manufacturing storage conditions are also a factor that may affect cleaner chemical integrity and its potential to leave a residue on the part. A variety of squeeze bottles stored in mild (72 F, 10 % R.H., dark) and harsh (105 F, 50 % R.H., fluorescent lighting) conditions were evaluated to determine the effect of environment and bottle exposure on the chemical composition of TCA (1,1,1 trichloroethane) replacement solvents. Low Density Polyethylene (LDPE) bottles were found to be quite permeable to all the cleaners evaluated in this study indicating this bottle type should not be used in the manufacturing area. Fluorinated Polyethylene (FLPE) bottles showed little cleaner loss and change in cleaner chemical composition over time suggesting these bottles would be acceptable for use. Chemical analysis indicates limonene-containing cleaners show increased non-volatile residue (NVR) content with storage under harsh conditions. Some cleaners use BHT (butylated hydroxytoluene) as stabilizer and to protect against limonene oxidation. Under harsh conditions, BHT was quickly depleted resulting in higher NVR levels.

  17. Reduction of Microbial Aerosols by Automatic Toilet Bowl Cleaners.

    ERIC Educational Resources Information Center

    Yahya, Moyasar; And Others

    1992-01-01

    A study of the impact of automatic toilet bowl cleaners on aerosol generation. Three toilet bowl cleaners containing 2.5, 6.7 or 18.2 percent surfactant materials were evaluated. Results indicate these cleaners significantly (p 0.05) reduce bacteria ejected from the bowl, and the cleaner containing the greatest amount of surfactant was the most…

  18. 7 CFR 58.230 - Heavy duty vacuum cleaners.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Heavy duty vacuum cleaners. 58.230 Section 58.230....230 Heavy duty vacuum cleaners. Each plant handling dry milk products shall be equipped with a heavy duty industrial vacuum cleaner. The vacuum cleaner shall be of a type that has a collector...

  19. 7 CFR 58.230 - Heavy duty vacuum cleaners.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Heavy duty vacuum cleaners. 58.230 Section 58.230....230 Heavy duty vacuum cleaners. Each plant handling dry milk products shall be equipped with a heavy duty industrial vacuum cleaner. The vacuum cleaner shall be of a type that has a collector...

  20. 7 CFR 58.230 - Heavy duty vacuum cleaners.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Heavy duty vacuum cleaners. 58.230 Section 58.230....230 Heavy duty vacuum cleaners. Each plant handling dry milk products shall be equipped with a heavy duty industrial vacuum cleaner. The vacuum cleaner shall be of a type that has a collector...

  1. 7 CFR 58.230 - Heavy duty vacuum cleaners.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Heavy duty vacuum cleaners. 58.230 Section 58.230....230 Heavy duty vacuum cleaners. Each plant handling dry milk products shall be equipped with a heavy duty industrial vacuum cleaner. The vacuum cleaner shall be of a type that has a collector...

  2. 7 CFR 58.230 - Heavy duty vacuum cleaners.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Heavy duty vacuum cleaners. 58.230 Section 58.230....230 Heavy duty vacuum cleaners. Each plant handling dry milk products shall be equipped with a heavy duty industrial vacuum cleaner. The vacuum cleaner shall be of a type that has a collector...

  3. 7 CFR 3201.100 - Aircraft and boat cleaners.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Aircraft and boat cleaners. 3201.100 Section 3201.100... Designated Items § 3201.100 Aircraft and boat cleaners. (a) Definition. (1) Aircraft and boat cleaners are... interior and exterior of aircraft and/or boats. (2) Aircraft and boat cleaners for which Federal...

  4. Optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits.

    PubMed

    Ozkan, Fahri; Tuna, M Cihat; Baylar, Ahmet; Ozturk, Mualla

    2014-01-01

    Oxygen is an important component of water quality and its ability to sustain life. Water aeration is the process of introducing air into a body of water to increase its oxygen saturation. Water aeration can be accomplished in a variety of ways, for instance, closed-conduit aeration. High-speed flow in a closed conduit involves air-water mixture flow. The air flow results from the subatmospheric pressure downstream of the gate. The air entrained by the high-speed flow is supplied by the air vent. The air entrained into the flow in the form of a large number of bubbles accelerates oxygen transfer and hence also increases aeration efficiency. In the present work, the optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits was studied experimentally. Results showed that aeration efficiency increased with the air-demand ratio to a certain point and then aeration efficiency did not change with a further increase of the air-demand ratio. Thus, there was an optimum value for the air-demand ratio, depending on the Froude number, which provides maximum aeration efficiency. Furthermore, a design formula for aeration efficiency was presented relating aeration efficiency to the air-demand ratio and Froude number. PMID:25225935

  5. Optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits.

    PubMed

    Ozkan, Fahri; Tuna, M Cihat; Baylar, Ahmet; Ozturk, Mualla

    2014-01-01

    Oxygen is an important component of water quality and its ability to sustain life. Water aeration is the process of introducing air into a body of water to increase its oxygen saturation. Water aeration can be accomplished in a variety of ways, for instance, closed-conduit aeration. High-speed flow in a closed conduit involves air-water mixture flow. The air flow results from the subatmospheric pressure downstream of the gate. The air entrained by the high-speed flow is supplied by the air vent. The air entrained into the flow in the form of a large number of bubbles accelerates oxygen transfer and hence also increases aeration efficiency. In the present work, the optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits was studied experimentally. Results showed that aeration efficiency increased with the air-demand ratio to a certain point and then aeration efficiency did not change with a further increase of the air-demand ratio. Thus, there was an optimum value for the air-demand ratio, depending on the Froude number, which provides maximum aeration efficiency. Furthermore, a design formula for aeration efficiency was presented relating aeration efficiency to the air-demand ratio and Froude number.

  6. GUIDE TO CLEANER TECHNOLOGIES: ORGANIC COATING REMOVAL

    EPA Science Inventory

    A cleaner technology is a source reduction or recycle method |applied to eliminate or significantly reduce hazardous waste generation. Source reduction includes product changes and source control. Source control can be further characterized as input material changes, technology...

  7. Monitoring and evaluation of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached houses in Austin, Texas

    SciTech Connect

    Burns, R.; Hough, R.E. and Associates, Inc., Syracuse, NY )

    1991-10-01

    The US DOE initiated this project to evaluate the performance of an air conditioner retrofit program in Austin, Texas. The City's Austin's Resource Management Department pursued this project to quantify the retrofit effect of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached homes. If successfully implemented, this retrofit program could help defer construction of a new power plant which is a major goal of this department. The project compares data collected from 12 houses during two cooling seasons under pre-retrofit and then post-retrofit air conditioner units. The existing low-efficiency air conditioners were monitored during the 1987 cooling season, replaced during the 1987--88 heating season with new, smaller sized, high-efficiency units, and then monitored again during the 1988 cooling season. Results indicated that the air conditioner retrofits reduce the annual air conditioner electric consumption and peak electric demand by an average of 38%. When normalized to the nominal capacity of the air conditioner, average demand savings were 1.12 W/ft{sup 2} and estimated annual energy savings were 1.419 kWh/ft{sup 2}. Individual air conditioner power requirements were found to be a well defined function of outdoor temperature as expected. In the absence of detailed data, estimates of the peak demand reductions of new air conditioners can be made from the manufacturer's specifications. Air conditioner energy consumption proved to be strongly linear as a function of the outdoor temperature as expected when taken as an aggregate. No noticeable differences in the diversity factor of the air conditioner usage were found. Analysis of the retrofit effect using PRISM yields estimates of the reduction in normalized annual consumption (NAC) and annual cooling consumption of 12% and 30%. 2 refs., 11 figs., 17 tabs.

  8. Cleaner fish Labroides dimidiatus recognise familiar clients.

    PubMed

    Tebbich, S; Bshary, R; Grutter, A S

    2002-09-01

    Individual recognition has been attributed a crucial role in the evolution of complex social systems such as helping behaviour and cooperation. A classical example for interspecific cooperation is the mutualism between the cleaner fish Labroides dimidiatus and its client reef fish species. For stable cooperation to evolve, it is generally assumed that partners interact repeatedly and remember each other's past behaviour. Repeated interactions may be achieved by site fidelity or individual recognition. However, as some cleaner fish have more than 2,300 interactions per day with various individuals per species and various species of clients, basic assumptions of cooperation theory might be violated in this mutualism. We tested the cleaner L. dimidiatus and its herbivorous client, the surgeon fish Ctenochaetus striatus, for their ability to distinguish between a familiar and an unfamiliar partner in a choice experiment. Under natural conditions, cleaners and clients have to build up their relationship, which is probably costly for both. We therefore predicted that both clients and cleaners should prefer the familiar partner in our choice experiment. We found that cleaners spent significantly more time near the familiar than the unfamiliar clients in the first 2 minutes of the experiment. This indicates the ability for individual recognition in cleaners. In contrast, the client C. striatus showed no significant preference. This could be due to a sampling artefact, possibly due to a lack of sufficient motivation. Alternatively, clients may not need to recognise their cleaners but instead remember the defined territories of L. dimidiatus to achieve repeated interactions with the same individual.

  9. Substitutes for ozone depleting aerosol electrical contact cleaners and cleaner/lubricants. Technical report

    SciTech Connect

    Bevilacqua, P.; Clark, K.G.

    1996-01-24

    With the production of Class I Ozone Depleting Substances discontinued as of January 1996, it became necessary to identify suitable replacements for chlorofluorocarbon (CFC-113) and trichloroethane (TCA) based electrical contact cleaners and cleaner/lubricant products. Two hydrochlorofluorocarbon (HCFC-141b) blends were identified as substitutes and recommended for interim use.

  10. Transparent air filter for high-efficiency PM2.5 capture

    NASA Astrophysics Data System (ADS)

    Liu, Chong; Hsu, Po-Chun; Lee, Hyun-Wook; Ye, Meng; Zheng, Guangyuan; Liu, Nian; Li, Weiyang; Cui, Yi

    2015-02-01

    Particulate matter (PM) pollution has raised serious concerns for public health. Although outdoor individual protection could be achieved by facial masks, indoor air usually relies on expensive and energy-intensive air-filtering devices. Here, we introduce a transparent air filter for indoor air protection through windows that uses natural passive ventilation to effectively protect the indoor air quality. By controlling the surface chemistry to enable strong PM adhesion and also the microstructure of the air filters to increase the capture possibilities, we achieve transparent, high air flow and highly effective air filters of ~90% transparency with >95.00% removal of PM2.5 under extreme hazardous air-quality conditions (PM2.5 mass concentration >250 μg m-3). A field test in Beijing shows that the polyacrylonitrile transparent air filter has the best PM2.5 removal efficiency of 98.69% at high transmittance of ~77% during haze occurrence.

  11. Transparent air filter for high-efficiency PM2.5 capture.

    PubMed

    Liu, Chong; Hsu, Po-Chun; Lee, Hyun-Wook; Ye, Meng; Zheng, Guangyuan; Liu, Nian; Li, Weiyang; Cui, Yi

    2015-01-01

    Particulate matter (PM) pollution has raised serious concerns for public health. Although outdoor individual protection could be achieved by facial masks, indoor air usually relies on expensive and energy-intensive air-filtering devices. Here, we introduce a transparent air filter for indoor air protection through windows that uses natural passive ventilation to effectively protect the indoor air quality. By controlling the surface chemistry to enable strong PM adhesion and also the microstructure of the air filters to increase the capture possibilities, we achieve transparent, high air flow and highly effective air filters of ~90% transparency with >95.00% removal of PM2.5 under extreme hazardous air-quality conditions (PM2.5 mass concentration >250 μg m(-3)). A field test in Beijing shows that the polyacrylonitrile transparent air filter has the best PM2.5 removal efficiency of 98.69% at high transmittance of ~77% during haze occurrence. PMID:25683688

  12. High-Efficiency Rooftop Air Conditioners: Small Commercial ACs Could Add Up to Big Energy Savings

    SciTech Connect

    Hollomon, J Bradford; Gilbride, Theresa L.

    2003-04-01

    This paper describes a technology procurement conducted by DOE, PNNL, and the Defense Logistics Agency to increase the availability of energy-efficient, packaged, unitary ''rooftop'' air conditioners. The procurement encourages air conditioner manufacturers to produce equipment that exceeds federal energy efficiency standards by at least 25 percent at a lower first cost. Program developers have also sought to aggregate market demand by organizing groups of large-volume buyers of air conditioning equipment. A Cost Estimator tool developed by PNNL to help consumers determine the cost effectiveness, based on local climate conditions, of purchasing energy efficient air conditioners for their own facilities is also described.

  13. POTENTIAL INHALATION EXPOSURE TO VOLATILE CHEMICALS IN WATER-BASED HARD-SURFACE CLEANERS

    EPA Science Inventory

    Potential inhalation exposure of building occupants to volatile chemicals in water-based hard-surface cleaners was evaluated by analyzing 267 material safety data sheets (MSDSs). Among the 154 chemicals reported, 44 are volatile or semi-volatile. Hazardous air pollutants (HAPs) r...

  14. Impaired odor perception in tank cleaners.

    PubMed

    Ahlström, R; Berglund, B; Berglund, U; Lindvall, T; Wennberg, A

    1986-12-01

    The olfactory perception of 20 men (tank cleaners) exposed to petroleum products (while cleaning oil tanks) was examined. Office workers and watchmen were used as referents (N = 20 + 20). They were matched with regard to sex, age, and smoking habits. Odor detection thresholds and the perceived odor intensity of four odorous stimuli, pyridine, dimethyl disulfide (DMDS), n-butanol, and heating oil vapor (gas phase of heating oil heated to +40 degrees C), were determined. The results suggested that the tank cleaners had higher absolute odor thresholds for n-butanol and oil vapor than the referents. The psychophysical function of the tank cleaners and referents differed for all the tested substances in respect to odor intensity. The tank cleaners displayed an odor deficit analogous to the hearing loss known as "loudness recruitment," ie, normal perception of strong stimuli but impaired perception of weak stimuli. This odor deficit was therefore named "odor intensity recruitment" and seems, in tank cleaners, to be associated with occupational exposure to oil vapor.

  15. Impaired odor perception in tank cleaners.

    PubMed

    Ahlström, R; Berglund, B; Berglund, U; Lindvall, T; Wennberg, A

    1986-12-01

    The olfactory perception of 20 men (tank cleaners) exposed to petroleum products (while cleaning oil tanks) was examined. Office workers and watchmen were used as referents (N = 20 + 20). They were matched with regard to sex, age, and smoking habits. Odor detection thresholds and the perceived odor intensity of four odorous stimuli, pyridine, dimethyl disulfide (DMDS), n-butanol, and heating oil vapor (gas phase of heating oil heated to +40 degrees C), were determined. The results suggested that the tank cleaners had higher absolute odor thresholds for n-butanol and oil vapor than the referents. The psychophysical function of the tank cleaners and referents differed for all the tested substances in respect to odor intensity. The tank cleaners displayed an odor deficit analogous to the hearing loss known as "loudness recruitment," ie, normal perception of strong stimuli but impaired perception of weak stimuli. This odor deficit was therefore named "odor intensity recruitment" and seems, in tank cleaners, to be associated with occupational exposure to oil vapor. PMID:3823805

  16. Improving indoor air quality through botanical air filtration in energy efficient residences

    NASA Astrophysics Data System (ADS)

    Newkirk, Daniel W.

    According to the U.S. EPA, the average American spends 90% of their time indoors where pollutants are two to five times more prevalent than outside. The consequences of these pollutants are estimated to cost the U.S. 125 billion dollars in lost health and productivity. Background literature suggests botanical air filtration may be able to solve this problem by leveraging the natural ability of plants to purify indoor air. By improving indoor air quality, energy consumption can also be reduced by bringing in less outside air to dilute contaminants within the space. A botanical air filter, called the Biowall, was designed and grown aeroponically in a sealed environmental chamber. Precise measurements of air temperature, air humidity, air quality and energy consumption were made under various lighting levels, plant species and watering strategies to optimize its performance. It was found to reduce indoor air pollutants 60 percent and has the potential to reduce heating and cooling energy consumption by 20 to 30 percent.

  17. High-Efficiency Rooftop Air Conditioners: Innovative Procurement to Achieve Advances in Technology

    SciTech Connect

    Hollomon, Brad

    2003-08-01

    The U.S. Department of Energy, Defense Logistics Agency, and Pacific Northwest National Laboratory recently conducted a technology procurement to increase the availability of energy-efficient, packaged unitary ''rooftop'' air conditioners. The procurement encouraged air conditioner manufacturers to produce equipment that exceeded US energy efficiency standards by at least 25% at a lower life-cycle cost. An outgrowth of the project, a web-based cost estimator tool is now available to help consumers determine the cost-effectiveness of purchasing energy-efficient air conditioners based on climate conditions and other factors at their own locations.

  18. Life cycle environmental impacts of vacuum cleaners and the effects of European regulation.

    PubMed

    Gallego-Schmid, Alejandro; Mendoza, Joan Manuel F; Jeswani, Harish Kumar; Azapagic, Adisa

    2016-07-15

    Energy efficiency of vacuum cleaners has been declining over the past decades while at the same time their number in Europe has been increasing. The European Commission has recently adopted an eco-design regulation to improve the environmental performance of vacuum cleaners. In addition to the existing directive on waste electrical and electronic equipment (WEEE), the regulation could potentially have significant effects on the environmental performance of vacuum cleaners. However, the scale of the effects is currently unknown, beyond scant information on greenhouse gas emissions. Thus, this paper considers for the first time life cycle environmental impacts of vacuum cleaners and the effects of the implementation of these regulations at the European level. The effects of electricity decarbonisation, product lifetime and end-of-life disposal options are also considered. The results suggest that the implementation of the eco-design regulation alone will reduce significantly the impacts from vacuum cleaners (37%-44%) by 2020 compared with current situation. If business as usual continued and the regulation was not implemented, the impacts would be 82%-109% higher by 2020 compared to the impacts with the implementation of the regulation. Improvements associated with the implementation of the WEEE directive will be much smaller (<1% in 2020). However, if the WEEE directive did not exist, then the impacts would be 2%-21% higher by 2020 relative to the impacts with the implementation of the directive. Further improvements in most impacts (6%-20%) could be achieved by decarbonising the electricity mix. Therefore, energy efficiency measures must be accompanied by appropriate actions to reduce the environmental impacts of electricity generation; otherwise, the benefits of improved energy efficiency could be limited. Moreover, because of expected lower life expectancy of vacuum cleaners and limited availability of some raw materials, the eco-design regulation should be

  19. Life cycle environmental impacts of vacuum cleaners and the effects of European regulation.

    PubMed

    Gallego-Schmid, Alejandro; Mendoza, Joan Manuel F; Jeswani, Harish Kumar; Azapagic, Adisa

    2016-07-15

    Energy efficiency of vacuum cleaners has been declining over the past decades while at the same time their number in Europe has been increasing. The European Commission has recently adopted an eco-design regulation to improve the environmental performance of vacuum cleaners. In addition to the existing directive on waste electrical and electronic equipment (WEEE), the regulation could potentially have significant effects on the environmental performance of vacuum cleaners. However, the scale of the effects is currently unknown, beyond scant information on greenhouse gas emissions. Thus, this paper considers for the first time life cycle environmental impacts of vacuum cleaners and the effects of the implementation of these regulations at the European level. The effects of electricity decarbonisation, product lifetime and end-of-life disposal options are also considered. The results suggest that the implementation of the eco-design regulation alone will reduce significantly the impacts from vacuum cleaners (37%-44%) by 2020 compared with current situation. If business as usual continued and the regulation was not implemented, the impacts would be 82%-109% higher by 2020 compared to the impacts with the implementation of the regulation. Improvements associated with the implementation of the WEEE directive will be much smaller (<1% in 2020). However, if the WEEE directive did not exist, then the impacts would be 2%-21% higher by 2020 relative to the impacts with the implementation of the directive. Further improvements in most impacts (6%-20%) could be achieved by decarbonising the electricity mix. Therefore, energy efficiency measures must be accompanied by appropriate actions to reduce the environmental impacts of electricity generation; otherwise, the benefits of improved energy efficiency could be limited. Moreover, because of expected lower life expectancy of vacuum cleaners and limited availability of some raw materials, the eco-design regulation should be

  20. Efficiency of dust sampling inlets in calm air.

    PubMed

    Breslin, J A; Stein, R L

    1975-08-01

    Measurement of airborne dust concentrations usually involves drawing a sample of the dust-laden air into the measuring instrument through an inlet. Even if the surrounding air is calm, theoretical calculations predict that large particles may not be sampled accurately due to the combined effects of gravity and inertia on the particles near the sampling inlet. Tests were conducted to determine the conditions of particle size, inlet radius, and flow rare necessary for accurate dust sampling. A coal-dust aerosol was sampled simultaneously through inlets of different diameters at the same volume flow-rate and collected on filters. The dust was removed from the filters and the particles were counted and sized with a Coulter counter. Results showed that published criteria for inlet conditions for correct sampling are overly restrictive and that respirable-size particles are sampled correctly in the normal range or operation of most dust sampling instruments. PMID:1227283

  1. 16 CFR 501.3 - Replacement bags for vacuum cleaners.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Replacement bags for vacuum cleaners. 501.3... REQUIREMENTS AND PROHIBITIONS UNDER PART 500 § 501.3 Replacement bags for vacuum cleaners. Replacement bags for vacuum cleaners, packaged and labeled for retail sale are exempt from the requirements of § 500.15a...

  2. 16 CFR 501.3 - Replacement bags for vacuum cleaners.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Replacement bags for vacuum cleaners. 501.3... REQUIREMENTS AND PROHIBITIONS UNDER PART 500 § 501.3 Replacement bags for vacuum cleaners. Replacement bags for vacuum cleaners, packaged and labeled for retail sale are exempt from the requirements of § 500.15a...

  3. 16 CFR 501.3 - Replacement bags for vacuum cleaners.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Replacement bags for vacuum cleaners. 501.3... REQUIREMENTS AND PROHIBITIONS UNDER PART 500 § 501.3 Replacement bags for vacuum cleaners. Replacement bags for vacuum cleaners, packaged and labeled for retail sale are exempt from the requirements of § 500.15a...

  4. 16 CFR 501.3 - Replacement bags for vacuum cleaners.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Replacement bags for vacuum cleaners. 501.3... REQUIREMENTS AND PROHIBITIONS UNDER PART 500 § 501.3 Replacement bags for vacuum cleaners. Replacement bags for vacuum cleaners, packaged and labeled for retail sale are exempt from the requirements of § 500.15a...

  5. 16 CFR 501.3 - Replacement bags for vacuum cleaners.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Replacement bags for vacuum cleaners. 501.3... REQUIREMENTS AND PROHIBITIONS UNDER PART 500 § 501.3 Replacement bags for vacuum cleaners. Replacement bags for vacuum cleaners, packaged and labeled for retail sale are exempt from the requirements of § 500.15a...

  6. 21 CFR 872.3530 - Mechanical denture cleaner.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Mechanical denture cleaner. 872.3530 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3530 Mechanical denture cleaner. (a) Identification. A mechanical denture cleaner is a device, usually AC-powered, that consists of a container...

  7. 21 CFR 872.3530 - Mechanical denture cleaner.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Mechanical denture cleaner. 872.3530 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3530 Mechanical denture cleaner. (a) Identification. A mechanical denture cleaner is a device, usually AC-powered, that consists of a container...

  8. 21 CFR 872.3530 - Mechanical denture cleaner.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Mechanical denture cleaner. 872.3530 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3530 Mechanical denture cleaner. (a) Identification. A mechanical denture cleaner is a device, usually AC-powered, that consists of a container...

  9. 7 CFR 3201.104 - Metal cleaners and corrosion removers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Metal cleaners and corrosion removers. 3201.104... FOR FEDERAL PROCUREMENT Designated Items § 3201.104 Metal cleaners and corrosion removers. (a... from metal surfaces. (2) Metal cleaners and corrosion removers for which Federal preferred...

  10. 21 CFR 878.4410 - Low energy ultrasound wound cleaner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Low energy ultrasound wound cleaner. 878.4410... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4410 Low energy ultrasound wound cleaner. (a) Identification. A low energy ultrasound wound cleaner is a device that...

  11. 21 CFR 878.4410 - Low energy ultrasound wound cleaner.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Low energy ultrasound wound cleaner. 878.4410... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4410 Low energy ultrasound wound cleaner. (a) Identification. A low energy ultrasound wound cleaner is a device that...

  12. 21 CFR 878.4410 - Low energy ultrasound wound cleaner.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Low energy ultrasound wound cleaner. 878.4410... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4410 Low energy ultrasound wound cleaner. (a) Identification. A low energy ultrasound wound cleaner is a device that...

  13. 21 CFR 878.4410 - Low energy ultrasound wound cleaner.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Low energy ultrasound wound cleaner. 878.4410... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4410 Low energy ultrasound wound cleaner. (a) Identification. A low energy ultrasound wound cleaner is a device that...

  14. 21 CFR 878.4410 - Low energy ultrasound wound cleaner.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Low energy ultrasound wound cleaner. 878.4410... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4410 Low energy ultrasound wound cleaner. (a) Identification. A low energy ultrasound wound cleaner is a device that...

  15. Toward cleaner, quieter skies: An international debate

    SciTech Connect

    Aylesworth, H. Jr.

    1997-12-31

    The paper summarizes infrastructure and technology changes in the aerospace industry aimed at reducing fuel consumption and nitrous oxide emissions. Growth of total air traffic is predicted over the next 20 years; however, emissions are predicted to grow less rapidly due to increased fuel efficiency and operational productivity. Engine technology leading to fuel efficiency, reduced emissions, and noise reduction is described. Regulations pertinent to these issues are outlined, and international efforts in these areas are also briefly described. 4 figs.

  16. Greater physical fitness is associated with better air ventilation efficiency in firefighters.

    PubMed

    Gendron, P; Freiberger, E; Laurencelle, L; Trudeau, F; Lajoie, C

    2015-03-01

    Firefighting is a hazardous task associated with a heavy workload where task duration may be limited by air cylinder capacity. Increased fitness may lead to better air ventilation efficiency and task duration at a given heavy work intensity. This study compared performance, air ventilation and skeletal muscle oxygen extraction during a maximal graded walking test (GWT), a 10 METS (metabolic equivalent) treadmill test (T10) and a simulated work circuit (SWC). Participants (n = 13) who performed the SWC in a shorter time had significantly lower air cylinder ventilation values on the T10 (r = -0.495), better peak oxygen consumption (r = -0.924) during the GWT and significantly greater skeletal muscle oxygen extraction during the SWC (HbDiff, r = 0.768). These results demonstrate that the fastest participants on the SWC had better air ventilation efficiency that could prolong interventions in difficult situations requiring air cylinder use. PMID:25479992

  17. GUIDE TO CLEANER TECHNOLOGIES: ORGANIC COATING REPLACEMENTS

    EPA Science Inventory

    This guide describes available and emerging cleaner technologies that can be used to reduce emissions and wastes from paint and coatings applications. Environmental concerns and increasing costs of organic chemicals and metals are leading to changes in the formulation of organic ...

  18. Building America Top Innovations 2013 Profile – High-Efficiency Window Air Conditioners

    SciTech Connect

    none,

    2013-09-01

    This Top Innovation profile explains how comprehensive performance testing by the National Renewable Energy Laboratory led to simple, affordable methods that homeowners could employ for increasing the energy efficiency of window air conditioners.

  19. States Address Air Pollution from Energy through Energy Efficiency and Renewable Energy Programs

    SciTech Connect

    Not Available

    2007-12-01

    This fact sheet highlights how renewable energy and energy efficiency technologies can and are being used to reduce air emissions and meet environmental goals, showcasing case studies and technology-specific topics.

  20. Influence of Ventilation Ratio on Desiccant Air Conditioning System's Efficiency Performance

    NASA Astrophysics Data System (ADS)

    Tran, Thien Nha; Akisawa, Atsushi; Kashiwagi, Takao; Hamamoto, Yoshinori

    Ventilation air is a concern for engineers since ventilated air controls indoor air contamination; additional ventilation, however, increases the energy consumption of buildings. The study investigates the energy efficiency performance of the desiccant dehumidification air conditioning system in the context of ventilation for a hot-humid climate such as summer in Japan. The investigation focuses on the variable ratio of ventilation air as required by the application of air conditioning system. The COP of the desiccant air conditioning system is determined. The evaluation is subsequently performed by comparing the desiccant based system with the conventional absorption cooling system and the vapor compression cooling system. Based on 12 desiccant rotor simulations, it is found that the desiccant regeneration temperature required varies between 47°C to 85°C as ventilation ratio increases from 0. 0 to 100%, and up to 52. 5°C as the ventilation ratio achieves 14%. The heat required for regenerating desiccant accounts for 55% and higher of the system's total heat consumption; the system is expected to be energy efficient by using wasted heat from the absorption chiller for desiccant regeneration; and its energy efficiency expands as the ratio of ventilation air rises above 15% compared with the conventional absorption cooling system. The energy efficiency also benefits as the ratio rises beyond 70% against the conventional vapor compression cooling system.

  1. Regenerating using aqueous cleaners with ozone and electrolysis

    NASA Astrophysics Data System (ADS)

    McGinness, Michael P.

    1994-02-01

    A new process converts organic oil and grease contaminates in used water based cleaners into synthetic surfactants. This permits the continued use of a cleaning solution long after it would have been dumped using previously known methods. Since the organic soils are converted from contaminates to cleaning compounds the need for frequent bath dumps is totally eliminated. When cleaning solutions used in aqueous cleaning systems are exhausted and ready for disposal, they will always contain the contaminates removed from the cleaned parts and drag-in from prior cleaning steps. Even when the cleaner is biodegradable these contaminants will frequently cause the waste cleaning solution to be a hazardous waste. Chlorinated solvents are rapidly being replaced by aqueous cleaners to avoid the new ozone-depletion product-labeling-law. Many industry standard halocarbon based solvents are being completely phased out of production, and their prices have nearly tripled. Waste disposal costs and cradle-to-grave liability are also major concerns for industry today. This new process reduces the amount of water and chemicals needed to maintain the cleaning process. The cost of waste disposal is eliminated because the water and cleaning compounds are reused. Energy savings result by eliminating the need for energy currently used to produce and deliver fresh water and chemicals as well as the energy used to treat and destroy the waste from the existing cleaning processes. This process also allows the cleaning bath to be maintained at the peak performance of a new bath resulting in decreased cycle times and decreased energy consumption needed to clean the parts. This results in a more efficient and cost effective cleaning process.

  2. Regenerating using aqueous cleaners with ozone and electrolysis

    NASA Technical Reports Server (NTRS)

    Mcginness, Michael P.

    1994-01-01

    A new process converts organic oil and grease contaminates in used water based cleaners into synthetic surfactants. This permits the continued use of a cleaning solution long after it would have been dumped using previously known methods. Since the organic soils are converted from contaminates to cleaning compounds the need for frequent bath dumps is totally eliminated. When cleaning solutions used in aqueous cleaning systems are exhausted and ready for disposal, they will always contain the contaminates removed from the cleaned parts and drag-in from prior cleaning steps. Even when the cleaner is biodegradable these contaminants will frequently cause the waste cleaning solution to be a hazardous waste. Chlorinated solvents are rapidly being replaced by aqueous cleaners to avoid the new ozone-depletion product-labeling-law. Many industry standard halocarbon based solvents are being completely phased out of production, and their prices have nearly tripled. Waste disposal costs and cradle-to-grave liability are also major concerns for industry today. This new process reduces the amount of water and chemicals needed to maintain the cleaning process. The cost of waste disposal is eliminated because the water and cleaning compounds are reused. Energy savings result by eliminating the need for energy currently used to produce and deliver fresh water and chemicals as well as the energy used to treat and destroy the waste from the existing cleaning processes. This process also allows the cleaning bath to be maintained at the peak performance of a new bath resulting in decreased cycle times and decreased energy consumption needed to clean the parts. This results in a more efficient and cost effective cleaning process.

  3. Traffic-related air pollution and respiratory tract efficiency.

    PubMed

    Badyda, A J; Dąbrowiecki, P; Czechowski, P O; Majewski, G; Doboszyńska, A

    2015-01-01

    High concentrations of air pollutants are characteristic of the vicinity of urban busy roads. Numerous studies have shown that these concentrations are significantly higher in comparison with areas located in a certain distance from roads and especially those in rural areas. Inhabitants living in the proximity of roads are, therefore, likely to be more exposed to adverse effects of air pollutants. On the basis of a study realized in 2008-2012 among nearly 5,000 residents of Warsaw and non-urbanized areas, we used generalized linear regression models (GRM) to identify factors that most significantly influence the variability of respiratory function variables. GRMs combine multiple classes of models and estimation methods such as simple, multiple, or factorial regression, ANOVA, ANCOVA, etc. Therefore, they allow receiving results based also on interactions between the independent variables. This paper presents the results of GRM for the forced expiratory volume in 1 s (FEV1) distribution. They indicate that the variation of FEV1 is associated with personal factors such as age, height, weight, BMI, or gender, as well as with factors related to the place of residence: traffic density, duration, and the floor of residence. The results clearly show that living in the proximity of busy roads in the city is linked with a significant decrease in FEV1 values.

  4. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy ? FY11 Final Report

    SciTech Connect

    Sidheswaran, Meera; Destaillats, Hugo; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William J.

    2011-10-31

    The research carried out in this project focuses on developing novel volatile organic compounds (VOCs) air cleaning technologies needed to enable energy-saving reductions in ventilation rates. we targeted a VOC air cleaning system that could enable a 50% reduction in ventilation rates. In a typical commercial HVAC system that provides a mixture of recirculated and outdoor air, a VOC air cleaner in the supply airstream must have a 15% to 20% VOC removal efficiency to counteract a 50% reduction in outdoor air supply.

  5. Preparation of Fiber Based Binder Materials to Enhance the Gas Adsorption Efficiency of Carbon Air Filter.

    PubMed

    Lim, Tae Hwan; Choi, Jeong Rak; Lim, Dae Young; Lee, So Hee; Yeo, Sang Young

    2015-10-01

    Fiber binder adapted carbon air filter is prepared to increase gas adsorption efficiency and environmental stability. The filter prevents harmful gases, as well as particle dusts in the air from entering the body when a human inhales. The basic structure of carbon air filter is composed of spunbond/meltblown/activated carbon/bottom substrate. Activated carbons and meltblown layer are adapted to increase gas adsorption and dust filtration efficiency, respectively. Liquid type adhesive is used in the conventional carbon air filter as a binder material between activated carbons and other layers. However, it is thought that the liquid binder is not an ideal material with respect to its bonding strength and liquid flow behavior that reduce gas adsorption efficiency. To overcome these disadvantages, fiber type binder is introduced in our study. It is confirmed that fiber type binder adapted air filter media show higher strip strength, and their gas adsorption efficiencies are measured over 42% during 60 sec. These values are higher than those of conventional filter. Although the differential pressure of fiber binder adapted air filter is relatively high compared to the conventional one, short fibers have a good potential as a binder materials of activated carbon based air filter.

  6. Comparison of the cutting efficiencies of electric motor and air turbine dental handpieces.

    PubMed

    Eikenberg, S L

    2001-01-01

    As part of a larger comprehensive performance evaluation to determine whether electric motor handpieces are a suitable substitute for air turbine handpieces in a portable field dental treatment and operating system, the cutting efficiencies of electric motor and air turbine handpieces were compared. A device was made that applies an identical cutting force to a glass ceramic material for each handpiece tested. The laboratory results show that with equal amounts of applied force, the electric motor handpiece cuts a glass ceramic material significantly more efficiently (volume of material removed per second) than does the air turbine. In clinical trials, after minimal experience utilizing the electric motor, the majority of dentists felt that the electric motor cut tooth and amalgam more efficiently than did the air turbine. PMID:12004701

  7. Personalised Adaptive Task Selection in Air Traffic Control: Effects on Training Efficiency and Transfer

    ERIC Educational Resources Information Center

    Salden, Ron J. C. M.; Paas, Fred; van Merrienboer, Jeroen J. G.

    2006-01-01

    The differential effects of four task selection methods on training efficiency and transfer in a computer-based training for Air Traffic Control were investigated. Two personalised conditions were compared with two corresponding yoked control conditions. The hypothesis that personalised adaptive task selection leads to more efficient training than…

  8. High efficiency particulate air filters. (Latest citations from the NTIS Bibliographic database). NewSearch

    SciTech Connect

    Not Available

    1994-10-01

    The bibliography contains citations concerning aspects of high efficiency particulate air (HEPA) filters. Topics include life cycle costs, efficiency, testing, and material compatibility. HEPA filter use in the gas treatment and nuclear industries is discussed. (Contains a minimum of 141 citations and includes a subject term index and title list.)

  9. ULTRA HIGH EFFICIENCY ESP DEVELOPMENT FOR AIR TOXICS CONTROL

    SciTech Connect

    David K. Anderson

    1999-11-01

    Because more than 90 percent of U.S. coal-fired utility boilers are equipped with electrostatic precipitators (ESPs), retrofitable ESP technologies represent a logical approach towards achieving the Department of Energy's (DOE) goal of a major reduction in fine particulate and mercury emissions (air toxics) from coal based power systems. EPA's recent issuance of significantly tightened ambient air standards for particles smaller than 2.5 {micro}m (PM{sub 2.5}) creates a new urgency for developing cost-effective means to control fine particulate emissions. This challenge is compounded by the on-going switch in the utility industry to low-sulfur Powder River Basin (PRB) coals, that generate higher resistivity and difficult-to-collect fly ash. Particulate emissions can increase by a factor of ten when a utility switches to a low-sulfur coal. Numerous power plants are presently limited in operation by the inability of their ESPs to control opacity at high loads. In Phase I of this program, ABB investigated five technologies to improve the collection of fine particulate and trace metals in ESPs. These included: (1) flue-gas cooling, (2) flue-gas humidification, (3) pulsed energization, (4) wet ESP and precharger modules, and (5) sorbent injection for mercury control. Tests were conducted with an Eastern bituminous coal and a Powder River Basin sub-bituminous low-sulfur coal in an integrated pilot-scale combustor and ESP test facility. The impacts of the different retrofit technologies on ESP performance, individually and in combination, were evaluated indepth through advanced sampling and measurement techniques. In Phase II, the most promising concepts identified from Phase I testing, flue-gas cooling and humidification, pulsed energization, and sorbent injection at low flue-gas temperatures for mercury control, were integrated into a commercially oriented sub-scale system for field testing at Commonwealth Edison's Waukegan Unit No. 8. The main objective of the proposed

  10. Catalysts for cleaner combustion of coal, wood and briquettes sulfur dioxide reduction options for low emission sources

    SciTech Connect

    Smith, P.V.

    1995-12-31

    Coal fired, low emission sources are a major factor in the air quality problems facing eastern European cities. These sources include: stoker-fired boilers which feed district heating systems and also meet local industrial steam demand, hand-fired boilers which provide heat for one building or a small group of buildings, and masonary tile stoves which heat individual rooms. Global Environmental Systems is marketing through Global Environmental Systems of Polane, Inc. catalysts to improve the combustion of coal, wood or fuel oils in these combustion systems. PCCL-II Combustion Catalysts promotes more complete combustion, reduces or eliminates slag formations, soot, corrosion and some air pollution emissions and is especially effective on high sulfur-high vanadium residual oils. Glo-Klen is a semi-dry powder continuous acting catalyst that is injected directly into the furnace of boilers by operating personnel. It is a multi-purpose catalyst that is a furnace combustion catalyst that saves fuel by increasing combustion efficiency, a cleaner of heat transfer surfaces that saves additional fuel by increasing the absorption of heat, a corrosion-inhibiting catalyst that reduces costly corrosion damage and an air pollution reducing catalyst that reduces air pollution type stack emissions. The reduction of sulfur dioxides from coal or oil-fired boilers of the hand fired stoker design and larger, can be controlled by the induction of the Glo-Klen combustion catalyst and either hydrated lime or pulverized limestone.

  11. Combustion Chemistry Diagnostics for Cleaner Processes.

    PubMed

    Kohse-Höinghaus, Katharina

    2016-09-12

    Climate change, environmental problems, urban pollution, and the dependence on fossil fuels demand cleaner, renewable energy strategies. However, they also ask for urgent advances in combustion science to reduce emissions. For alternative fuels and new combustion regimes, crucial information about the chemical reactions from fuel to exhaust remains lacking. Understanding such relations between combustion process, fuel, and emissions needs reliable experimental data from a wide range of conditions to provide a firm basis for predictive modeling of practical combustion processes.

  12. Combustion Chemistry Diagnostics for Cleaner Processes.

    PubMed

    Kohse-Höinghaus, Katharina

    2016-09-12

    Climate change, environmental problems, urban pollution, and the dependence on fossil fuels demand cleaner, renewable energy strategies. However, they also ask for urgent advances in combustion science to reduce emissions. For alternative fuels and new combustion regimes, crucial information about the chemical reactions from fuel to exhaust remains lacking. Understanding such relations between combustion process, fuel, and emissions needs reliable experimental data from a wide range of conditions to provide a firm basis for predictive modeling of practical combustion processes. PMID:27440049

  13. Improving the efficiency of residential air-distribution systems in California, Phase 1

    SciTech Connect

    Modera, M.; Dickerhoff, D.; Jansky, R.; Smith, B.

    1992-06-01

    This report describes the results of the first phase of a multiyear research project. The project`s goal is to investigate ways to improve the efficiency of air-distribution systems in detached, single-family residences in California. First-year efforts included: A survey of heating, ventilating, and air conditioning (HVAC) contractors in California. A 31-house field study of distribution-system performance based on diagnostic measurements. Development of an integrated air-flow and thermal-simulation tool for investigating residential air-distribution system performance. Highlights of the field results include the following: Building envelopes for houses built after 1979 appear to be approximately 30% tighter. Duct-system tightness showed no apparent improvement in post-1979 houses. Distribution-fan operation added an average of 0.45 air changes per hour (ACH) to the average measured rate of 0.24 ACH. The simulation tool developed is based on DOE-2 for the thermal simulations and on MOVECOMP, an air-flow network simulation model, for the duct/house leakage and flow interactions. The first complete set of simulations performed (for a ranch house in Sacramento) indicated that the overall heating-season efficiency of the duct systems was approximately 65% to 70% and that the overall cooling-season efficiency was between 60% and 75%. The wide range in cooling-season efficiency reflects the difference between systems with attic return ducts and those with crawl-space return ducts, the former being less efficient. The simulations also indicated that the building envelope`s UA-value, a measurement of thermoconductivity, did not have a significant impact on the overall efficiency of the air-distribution system.

  14. Abating air pollution at negative cost via energy efficiency

    SciTech Connect

    Lovins, A.B. )

    1989-11-01

    Advanced techniques for energy end-use efficiency can pay for very large direct and indirect reductions in emissions, usually with money left over. This permits much more complete abatements than are often analyzed, and not at a cost but at a large profit. The order of economic priority, however, is also the order of environmental priority. Choosing the best buys first maximizes abatement per dollar; Choosing anything else first thus reduces abatement per dollar. To achieve the largest, fastest abatement therefore requires that the Chinese-restaurant-menu approach to energy investments-buying one option from Column A, one from Column B, etc., until all constituencies are satisfied-give way to the least-cost approach that is now the expressed (if less often the observed) policy of utility regulations in more than 40 states. The powerful supply-curve method of identifying priorities is therefore valid only if pollution prevention is considered together with, and allowed to precede and even to displace as well as augment, the more traditional end-of-pipe technologies.

  15. A cost-efficiency and health benefit approach to improve urban air quality.

    PubMed

    Miranda, A I; Ferreira, J; Silveira, C; Relvas, H; Duque, L; Roebeling, P; Lopes, M; Costa, S; Monteiro, A; Gama, C; Sá, E; Borrego, C; Teixeira, J P

    2016-11-01

    When ambient air quality standards established in the EU Directive 2008/50/EC are exceeded, Member States are obliged to develop and implement Air Quality Plans (AQP) to improve air quality and health. Notwithstanding the achievements in emission reductions and air quality improvement, additional efforts need to be undertaken to improve air quality in a sustainable way - i.e. through a cost-efficiency approach. This work was developed in the scope of the recently concluded MAPLIA project "Moving from Air Pollution to Local Integrated Assessment", and focuses on the definition and assessment of emission abatement measures and their associated costs, air quality and health impacts and benefits by means of air quality modelling tools, health impact functions and cost-efficiency analysis. The MAPLIA system was applied to the Grande Porto urban area (Portugal), addressing PM10 and NOx as the most important pollutants in the region. Four different measures to reduce PM10 and NOx emissions were defined and characterized in terms of emissions and implementation costs, and combined into 15 emission scenarios, simulated by the TAPM air quality modelling tool. Air pollutant concentration fields were then used to estimate health benefits in terms of avoided costs (external costs), using dose-response health impact functions. Results revealed that, among the 15 scenarios analysed, the scenario including all 4 measures lead to a total net benefit of 0.3M€·y(-1). The largest net benefit is obtained for the scenario considering the conversion of 50% of open fire places into heat recovery wood stoves. Although the implementation costs of this measure are high, the benefits outweigh the costs. Research outcomes confirm that the MAPLIA system is useful for policy decision support on air quality improvement strategies, and could be applied to other urban areas where AQP need to be implemented and monitored.

  16. A cost-efficiency and health benefit approach to improve urban air quality.

    PubMed

    Miranda, A I; Ferreira, J; Silveira, C; Relvas, H; Duque, L; Roebeling, P; Lopes, M; Costa, S; Monteiro, A; Gama, C; Sá, E; Borrego, C; Teixeira, J P

    2016-11-01

    When ambient air quality standards established in the EU Directive 2008/50/EC are exceeded, Member States are obliged to develop and implement Air Quality Plans (AQP) to improve air quality and health. Notwithstanding the achievements in emission reductions and air quality improvement, additional efforts need to be undertaken to improve air quality in a sustainable way - i.e. through a cost-efficiency approach. This work was developed in the scope of the recently concluded MAPLIA project "Moving from Air Pollution to Local Integrated Assessment", and focuses on the definition and assessment of emission abatement measures and their associated costs, air quality and health impacts and benefits by means of air quality modelling tools, health impact functions and cost-efficiency analysis. The MAPLIA system was applied to the Grande Porto urban area (Portugal), addressing PM10 and NOx as the most important pollutants in the region. Four different measures to reduce PM10 and NOx emissions were defined and characterized in terms of emissions and implementation costs, and combined into 15 emission scenarios, simulated by the TAPM air quality modelling tool. Air pollutant concentration fields were then used to estimate health benefits in terms of avoided costs (external costs), using dose-response health impact functions. Results revealed that, among the 15 scenarios analysed, the scenario including all 4 measures lead to a total net benefit of 0.3M€·y(-1). The largest net benefit is obtained for the scenario considering the conversion of 50% of open fire places into heat recovery wood stoves. Although the implementation costs of this measure are high, the benefits outweigh the costs. Research outcomes confirm that the MAPLIA system is useful for policy decision support on air quality improvement strategies, and could be applied to other urban areas where AQP need to be implemented and monitored. PMID:27348699

  17. Lighting energy efficiency opportunities at Cheyenne Mountain Air Station

    SciTech Connect

    Molburg, J.C.; Rozo, A.J.; Sarles, J.K.; Haffenden, R.A.; Thimmapuram, P.R.; Cavallo, J.D.

    1996-06-01

    CMAS is an intensive user of electricity for lighting because of its size, lack of daylight, and 24-hour operating schedule. Argonne National Laboratory recently conducted a lighting energy conservation evaluation at CMAS. The evaluation included inspection and characterization of existing lighting systems, analysis of energy-efficient retrofit options, and investigation of the environmental effects that these lighting system retrofits could have when they are ready to be disposed of as waste. Argonne devised three retrofit options for the existing lighting systems at various buildings: (1) minimal retrofit--limited fixture replacement; (2) moderate retrofit--more extensive fixture replacement and limited application of motion detectors; and (3) advanced retrofit--fixture replacement, reduction in the number of lamps, expansion of task lighting, and more extensive application of motion detectors. Argonne used data on electricity consumption to analyze the economic and energy effects of these three retrofit options. It performed a cost analysis for each retrofit option in terms of payback. The analysis showed that lighting retrofits result in savings because they reduce electricity consumption, cooling load, and maintenance costs. The payback period for all retrofit options was found to be less than 2 years, with the payback period decreasing for more aggressive retrofits. These short payback periods derived largely from the intensive (24-hours-per-day) use of electric lighting at the facility. Maintenance savings accounted for more than half of the annual energy-related savings under the minimal and moderate retrofit options and slightly less than half of these savings under the advanced retrofit option. Even if maintenance savings were excluded, the payback periods would still be impressive: about 4.4 years for the minimal retrofit option and 2 years for the advanced option. The local and regional environmental impacts of the three retrofit options were minimal.

  18. 10 CFR 431.96 - Uniform test method for the measurement of energy efficiency of commercial air conditioners and...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Air Conditioners and Heat Pumps Test Procedures § 431.96 Uniform test method for the measurement of energy efficiency of commercial air conditioners and heat pumps. (a) Scope. This section contains test... efficiency of commercial air conditioners and heat pumps. 431.96 Section 431.96 Energy DEPARTMENT OF...

  19. Product lifetime, energy efficiency and climate change: A case study of air conditioners in Japan.

    PubMed

    Nishijima, Daisuke

    2016-10-01

    This study proposed a modelling technique for estimating life-cycle CO2 emissions of durable goods by considering changes in product lifetime and energy efficiency. The stock and flow of durable goods was modelled by Weibull lifetime distributions and the trend in annual energy efficiency (i.e., annual electricity consumption) of an "average" durable good was formulated as a reverse logistic curve including a technologically critical value (i.e., limit energy efficiency) with respect to time. I found that when the average product lifetime is reduced, there is a trade-off between the reduction in emissions during product use (use phase), due to the additional purchases of new, more energy-efficient air conditioners, and the increase in emissions arising from the additional production of new air conditioners stimulated by the reduction of the average product lifetime. A scenario analysis focused on residential air conditioners in Japan during 1972-2013 showed that for a reduction of average lifetime of 1 year, if the air conditioner energy efficiency limit can be improved by 1.4% from the estimated current efficiency level, then CO2 emissions can be reduced by approximately the same amount as for an extension of average product lifetime of 1 year. PMID:27423771

  20. Product lifetime, energy efficiency and climate change: A case study of air conditioners in Japan.

    PubMed

    Nishijima, Daisuke

    2016-10-01

    This study proposed a modelling technique for estimating life-cycle CO2 emissions of durable goods by considering changes in product lifetime and energy efficiency. The stock and flow of durable goods was modelled by Weibull lifetime distributions and the trend in annual energy efficiency (i.e., annual electricity consumption) of an "average" durable good was formulated as a reverse logistic curve including a technologically critical value (i.e., limit energy efficiency) with respect to time. I found that when the average product lifetime is reduced, there is a trade-off between the reduction in emissions during product use (use phase), due to the additional purchases of new, more energy-efficient air conditioners, and the increase in emissions arising from the additional production of new air conditioners stimulated by the reduction of the average product lifetime. A scenario analysis focused on residential air conditioners in Japan during 1972-2013 showed that for a reduction of average lifetime of 1 year, if the air conditioner energy efficiency limit can be improved by 1.4% from the estimated current efficiency level, then CO2 emissions can be reduced by approximately the same amount as for an extension of average product lifetime of 1 year.

  1. Improving Compressed Air Energy Efficiency in Automotive Plants - Practical Examples and Implementation

    SciTech Connect

    Alkadi, Nasr E; Kissock, Professor Kelly

    2011-01-01

    The automotive industry is the largest industry in the United States in terms of the dollar value of production [1]. U.S. automakers face tremendous pressure from foreign competitors, which have an increasing manufacturing presence in this country. The Big Three North American Original Equipment Manufacturers (OEMs) General Motors, Ford, and Chrysler are reacting to declining sales figures and economic strain by working more efficiently and seeking out opportunities to reduce production costs without negatively affecting the production volume or the quality of the product. Successful, cost-effective investment and implementation of the energy efficiency technologies and practices meet the challenge of maintaining the output of high quality product with reduced production costs. Automotive stamping and assembly plants are typically large users of compressed air with annual compressed air utility bills in the range of $2M per year per plant. This paper focuses on practical methods that the authors have researched, analyzed and implemented to improve compressed air system efficiency in automobile manufacturing facilities. It describes typical compressed air systems in automotive stamping and assembly plants, and compares these systems to best practices. The paper then presents a series of examples, organized using the method of inside-out approach, which strategically identifies the energy savings in the compressed air system by first minimizing end-use demand, then minimizing distribution losses, and finally making improvements to primary energy conversion equipment, the air compressor plant.

  2. Into Thin Air.

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2001-01-01

    Shows how schools are working to avoid the types of equipment, supplies, and maintenance practices that harm indoor air quality. Simple steps to maintaining a cleaner indoor air environment are highlighted as are steps to reducing the problem air quality and the occurrence of asthma. (GR)

  3. Designing a leaner, cleaner machine

    SciTech Connect

    Valenti, M.

    1997-05-01

    With factories cutting back on emissions and municipalities stepping up recycling efforts, environmentalists have cast automobiles as the primary pollution culprit. A concept car called the XCAR, which incorporates a fuel-efficient, low-pollution engine from Australia, may one day rehabilitate automobiles` bad environmental reputation. The XCAR is being designed by XCORP in Malibu, Calif. The company was founded in 1991 to transfer cutting-edge aerospace and defense technologies to business and manufacturing applications. Their goals are to design a next-generation automobile that will use less energy; provide a higher degree of safety by being more impact-resistant; reduce stress on roads, highways, and bridges by its lighter weight, thus extending the life of infrastructure; and be easily recycled and repaired. The company is developing a roadster, a subcompact coupe, and a sports/utility version of the XCAR for American civilian use, as well as a general-purpose version for the US military and a multipurpose car for developing nations. The design of the XCAR includes molded thermoplastic panels, which reduces the vehicle`s overall weight. Thermoplastic also lowers the energy needed to stamp steel parts by eliminating the by-products generated from spot-welding, drilling, and riveting, such as welding fumes and spent machining oils. Using large, molded thermoplastic/aluminum sections for much of the chassis and body assemblies will also reduce the number of parts required by a third compared to conventional autos. In addition, paint application and its attendant solvents are eliminated because the color is molded into the plastic body.

  4. Cleaner cooking solutions to achieve health, climate, and economic cobenefits.

    PubMed

    Anenberg, Susan C; Balakrishnan, Kalpana; Jetter, James; Masera, Omar; Mehta, Sumi; Moss, Jacob; Ramanathan, Veerabhadran

    2013-05-01

    Nearly half the world's population must rely on solid fuels such as biomass (wood, charcoal, agricultural residues, and animal dung) and coal for household energy, burning them in inefficient open fires and stoves with inadequate ventilation. Household solid fuel combustion is associated with four million premature deaths annually; contributes to forest degradation, loss of habitat and biodiversity, and climate change; and hinders social and economic progress as women and children spend hours every day collecting fuel. Several recent studies, as well as key emerging national and international efforts, are making progress toward enabling wide-scale household adoption of cleaner and more efficient stoves and fuels. While significant challenges remain, these efforts offer considerable promise to save lives, improve forest sustainability, slow climate change, and empower women around the world.

  5. Air

    MedlinePlus

    ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be polluted indoors and it can ... this chart to see what things cause indoor air pollution and what things cause outdoor air pollution! Indoor ...

  6. Vacuum cleaner modifications leading to reduced ESD hazards

    SciTech Connect

    Jones, R.D.; Chen, K.C.; Holmes, S.W.

    1994-03-01

    After a series of meetings held in response to an Unsatisfactory Report on the use of vacuum cleaners, an experimental study of commonly available vacuum cleaners was conducted. The object of the study was to evaluate the effectiveness of the cleaners as electrostatic generators. The electrical charges generated by the machine can inadvertently be transferred in normal operations to electroexplosive devices (EEDs), thereby creating a potentially hazardous situation. In the course of this study, it was determined that many inexpensive commercial cleaners could be used safely providing certain modifications were made. Details of the required modification and rationale for the modification are presented in this report.

  7. Particle resuspension during the use of vacuum cleaners on residential carpet.

    PubMed

    Corsi, Richard L; Siegel, Jeffrey A; Chiang, Chunyi

    2008-04-01

    Vacuuming is generally considered to be an important activity with respect to the cleanliness of indoor environments but may lead to short-term resuspension of particulate matter and elevated particle mass in indoor air. Because resuspended particles often contain toxicants, such as lead and pesticides, or consist of biological agents that can trigger allergic reactions, it is important to understand the role of vacuuming on short-term variations in indoor particulate matter concentrations. The inhalation of particles during vacuuming events may affect adversely those whose occupation requires them to clean a wide range of indoor environments, from homes to schools and offices, as well as those who occupy those environments. In response, a series of 46 experiments was completed to determine time-variant concentrations of both PM(10) and PM(2.5) during various vacuuming activities in 12 separate apartments. Experiments involved the use of two different non-HEPA vacuum cleaners and were completed with a vacuum cleaner activated (switched on) as well as deactivated (switched off). The latter was intended to provide insight on the potential for resuspension of particles by the mechanical agitation of vacuum cleaner movement across carpet. Separate experiments were completed also using "mock" vacuuming simulations, that is, walking on the carpet in a manner consistent with using a vacuum cleaner. Results are presented as incremental particulate matter concentration increases, relative to background (prevacuum) concentrations, and peak-to-background particle concentration ratios. Results indicate significant resuspension of PM(10) mass during vacuum cleaning, with a mean time-averaged PM(10) increase of greater than 17 mu g/m(3) above background. Resuspension of PM(2.5) mass was determined to be small, that is, PM(10) mass was dominated by particles greater than 2.5 mu m. The frequency of vacuuming (between a 10-day standard frequency and several experiments at > 24 days

  8. Reducing ink and cleaner waste: A flexographic printer moves to water-based inks and cleaners

    SciTech Connect

    Miller, G.D.; Tancig, W.J.; Plewa, M.J.; Randall, P.M.

    1994-01-01

    Changing from alcohol-based inks and cleaners can reduce the amount and toxicity of emissions and waste, while also improving product quality and saving money. The article explores how a flexographic printer successfully made the switch without incurring significant capital costs or increasing operational expenses.

  9. Desiccant Enhanced Evaporative Air-Conditioning (DEVap): Evaluation of a New Concept in Ultra Efficient Air Conditioning

    SciTech Connect

    Kozubal, E.; Woods, J.; Burch, J.; Boranian, A.; Merrigan, T.

    2011-01-01

    NREL has developed the novel concept of a desiccant enhanced evaporative air conditioner (DEVap) with the objective of combining the benefits of liquid desiccant and evaporative cooling technologies into an innovative 'cooling core.' Liquid desiccant technologies have extraordinary dehumidification potential, but require an efficient cooling sink. DEVap's thermodynamic potential overcomes many shortcomings of standard refrigeration-based direct expansion cooling. DEVap decouples cooling and dehumidification performance, which results in independent temperature and humidity control. The energy input is largely switched away from electricity to low-grade thermal energy that can be sourced from fuels such as natural gas, waste heat, solar, or biofuels.

  10. First principles calculations of air fluorescence efficiencies with comparisons to measurements

    SciTech Connect

    Colman, J. J.

    2004-01-01

    The fluorescence efficiencies used in calculating the optical emissions produced by energetic particles and penetrating radiation in air are derived for the most part from the measurements, of Davidson and O'neil, Mitchell and Hartman. These efficiencies were obtained from experiments conducted at various air pressures and in the absence of an applied electric field. In this paper we describe detailed 4.5 dimensional (two spatial dimensions and 2.5 phase space dimensions) kinetic calculations for the electron distribution function resulting from the injection of energetic electrons into air at various pressures. We choose beam parameters and dimensions that are directly relevant to the original Davidson and O'Neil experiments. From the electron distribution function and measured excitation cross-sections we then compute the optical efficiencies for a large number of nitrogen and oxygen lines across the electromagnetic spectrum from 320.0 nm to 800.0 nm. A comparison with various measurements is presented. We also present results from simulations with an applied electric field. The computed fluorescence efficiencies can be used to determine the optical emissions associated with high-altitude discharges driven by runaway air breakdown and results are discussed in a separate poster. We have also recalculated optical emission rates that are applicable to discharges dominated by. conventional breakdown for comparison with Taranenko et al. These rates are also used in our self-consistent sprite simulations.

  11. Indoor air-quality measurements in energy-efficient residential buildings

    SciTech Connect

    Berk, J.V.; Hollowell, C.D.; Pepper, J.H.; Young, R.

    1980-05-01

    The potential impact on indoor air quality of energy-conserving measures that reduce ventilation is being assessed in a field-monitoring program conducted by the Lawrence Berkeley Laboratory. Using a mobile laboratory, on-site monitoring of infiltration rate, carbon dioxide, carbon monoxide, nitrogen dioxide, nitric oxide, ozone, sulfur dioxide, formaldehyde, total aldehydes, and particulates was conducted in three houses designed to be energy-efficient. Preliminary results show that energy-conserving design features that reduce air-exchange rates compromise indoor air quality; specifically, indoor levels of several pollutants were found to exceed levels detected outdoors. Although the indoor levels of most pollutants are within limits established by present outdoor air-quality standards, considerable work remains to be accomplished before health-risk effects can be accurately assessed and broad-scale regulatory guidelines revised to comply with energy-conservation goals.

  12. Technical, occupational health and environmental aspects of metal degreasing with aqueous cleaners.

    PubMed

    Lavoué, Jérôme; Bégin, Denis; Géerin, Michel

    2003-08-01

    Aqueous cleaners used for metal degreasing are detergent formulations containing surfactants (such as linear alkylbenzene sulphonates, alkylphenol ethoxylates or alcohol ethoxylates), builders (such as hydroxides, phosphates or silicates), sequestrants (such as EDTA or NTA), anti-corrosive agents (such as ethanolamines), solvents (such as glycol ethers or d-limonene) and other specialty additives. Generally sold as concentrates, they are typically diluted between 3 and 20 times in water, leading to solutions containing only a few per cent active products. The cleaning efficiency depends on physicochemical phenomena such as wetting, solubilization, emulsification, dispersion, sequestration and saponification, and is enhanced by thermal and mechanical energy. Cleaning equipment is based on spraying or immersion of the parts and may include drying and rinsing steps. Because of the complexity and variability of the mixtures, the occupational health and environmental evaluation of aqueous cleaners is based on the study of their components. Aqueous cleaners are generally believed to present a low risk to workers' health and to the environment. However, some anionic surfactants and strong alkalis are skin and eye irritants, ethanolamines are allergenic and several glycol ethers of the ethylene glycol family are proven systemic toxicants that are easily absorbed through the skin. Although most components of aqueous cleaners are biodegradable and of low ecotoxicity, alkylphenol ethoxylates degrade into persistent and toxic compounds. Phosphates, if released directly into the environment, may cause eutrophication of rivers and lakes. Waste recycling or treatment by specialized facilities is usually required for spent solutions containing contaminants such as oils and heavy metals. From a technical, toxicological and environmental standpoint, aqueous cleaners can be used successfully to replace traditional organic solvents used in metal degreasing.

  13. Technical, occupational health and environmental aspects of metal degreasing with aqueous cleaners.

    PubMed

    Lavoué, Jérôme; Bégin, Denis; Géerin, Michel

    2003-08-01

    Aqueous cleaners used for metal degreasing are detergent formulations containing surfactants (such as linear alkylbenzene sulphonates, alkylphenol ethoxylates or alcohol ethoxylates), builders (such as hydroxides, phosphates or silicates), sequestrants (such as EDTA or NTA), anti-corrosive agents (such as ethanolamines), solvents (such as glycol ethers or d-limonene) and other specialty additives. Generally sold as concentrates, they are typically diluted between 3 and 20 times in water, leading to solutions containing only a few per cent active products. The cleaning efficiency depends on physicochemical phenomena such as wetting, solubilization, emulsification, dispersion, sequestration and saponification, and is enhanced by thermal and mechanical energy. Cleaning equipment is based on spraying or immersion of the parts and may include drying and rinsing steps. Because of the complexity and variability of the mixtures, the occupational health and environmental evaluation of aqueous cleaners is based on the study of their components. Aqueous cleaners are generally believed to present a low risk to workers' health and to the environment. However, some anionic surfactants and strong alkalis are skin and eye irritants, ethanolamines are allergenic and several glycol ethers of the ethylene glycol family are proven systemic toxicants that are easily absorbed through the skin. Although most components of aqueous cleaners are biodegradable and of low ecotoxicity, alkylphenol ethoxylates degrade into persistent and toxic compounds. Phosphates, if released directly into the environment, may cause eutrophication of rivers and lakes. Waste recycling or treatment by specialized facilities is usually required for spent solutions containing contaminants such as oils and heavy metals. From a technical, toxicological and environmental standpoint, aqueous cleaners can be used successfully to replace traditional organic solvents used in metal degreasing. PMID:12890654

  14. Successes emerge in search for cleaner processes

    SciTech Connect

    Not Available

    1992-12-09

    Faced with mounting public and regulatory pressures, many chemical producers have long adopted pollution reduction efforts. But increasingly, firms are eyeing fundamental process changes to achieve cleaner technologies. In addition to environmental benefits, the promised economic payoffs are clear: higher yields and an escape from soaring waste treatment and disposal costs. Having such technologies, says Paolo Galli, Montecatini's (Milan) director/corporate research, is a tremendous tool. It's becoming an increasingly important competitive element. Indeed, suggests David Hyde, ICI's (London) manager/environmental technology, everyone is looking to use cleaner technologies for a competitive advantage. A number of leading technology groups, including UOP (Des Plaines, IL), are working on replacing hydrofluoric acid (HF) with solid catalysts in alkylation processes. Although it is technologically tough to replace HF or alternative sulfuric acid technology, the rewards could be huge in producing high-octane fuel additives. Catalytica (Mountain View, CA), for one, is building a pilot plant with partners Neste (Helsinki) and Du Pont's Conoco. The company has developed a process to manufacture high-purity DMC by direct synthesis from carbom monoxide, methanol, and oxygen. The medium-pressure process uses a copper salts catalyst system; EniChem says the only significant by-product is carbon dioxide, and there are no chlorinated impurities.

  15. 7 CFR 2902.35 - Bathroom and spa cleaners.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Bathroom and spa cleaners. 2902.35 Section 2902.35 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF ENERGY POLICY AND NEW USES... Items § 2902.35 Bathroom and spa cleaners. (a) Definition. Products that are designed to clean...

  16. 7 CFR 3201.55 - Ink removers and cleaners.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Ink removers and cleaners. 3201.55 Section 3201.55... Designated Items § 3201.55 Ink removers and cleaners. (a) Definition. Chemical products designed to remove ink, haze, glaze, and other residual ink contaminants from the surfaces of equipment, such as...

  17. 7 CFR 3201.55 - Ink removers and cleaners.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 15 2012-01-01 2012-01-01 false Ink removers and cleaners. 3201.55 Section 3201.55... Designated Items § 3201.55 Ink removers and cleaners. (a) Definition. Chemical products designed to remove ink, haze, glaze, and other residual ink contaminants from the surfaces of equipment, such as...

  18. 7 CFR 3201.55 - Ink removers and cleaners.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Ink removers and cleaners. 3201.55 Section 3201.55... Designated Items § 3201.55 Ink removers and cleaners. (a) Definition. Chemical products designed to remove ink, haze, glaze, and other residual ink contaminants from the surfaces of equipment, such as...

  19. 7 CFR 2902.55 - Ink removers and cleaners.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Ink removers and cleaners. 2902.55 Section 2902.55... Items § 2902.55 Ink removers and cleaners. (a) Definition. Chemical products designed to remove ink, haze, glaze, and other residual ink contaminants from the surfaces of equipment, such as rollers,...

  20. 21 CFR 872.3530 - Mechanical denture cleaner.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Mechanical denture cleaner. 872.3530 Section 872.3530 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3530 Mechanical denture cleaner....

  1. 21 CFR 872.3530 - Mechanical denture cleaner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mechanical denture cleaner. 872.3530 Section 872.3530 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3530 Mechanical denture cleaner....

  2. 7 CFR 3201.34 - Carpet and upholstery cleaners.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 15 2012-01-01 2012-01-01 false Carpet and upholstery cleaners. 3201.34 Section 3201... PROCUREMENT Designated Items § 3201.34 Carpet and upholstery cleaners. (a) Definition. (1) Cleaning products formulated specifically for use in cleaning carpets and upholstery, through a dry or wet process, found...

  3. 7 CFR 2902.34 - Carpet and upholstery cleaners.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Carpet and upholstery cleaners. 2902.34 Section 2902... PROCUREMENT Designated Items § 2902.34 Carpet and upholstery cleaners. (a) Definition. (1) Cleaning products formulated specifically for use in cleaning carpets and upholstery, through a dry or wet process, found...

  4. 7 CFR 3201.34 - Carpet and upholstery cleaners.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Carpet and upholstery cleaners. 3201.34 Section 3201... PROCUREMENT Designated Items § 3201.34 Carpet and upholstery cleaners. (a) Definition. (1) Cleaning products formulated specifically for use in cleaning carpets and upholstery, through a dry or wet process, found...

  5. 7 CFR 3201.34 - Carpet and upholstery cleaners.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Carpet and upholstery cleaners. 3201.34 Section 3201... PROCUREMENT Designated Items § 3201.34 Carpet and upholstery cleaners. (a) Definition. (1) Cleaning products formulated specifically for use in cleaning carpets and upholstery, through a dry or wet process, found...

  6. 7 CFR 2902.34 - Carpet and upholstery cleaners.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Carpet and upholstery cleaners. 2902.34 Section 2902... PROCUREMENT Designated Items § 2902.34 Carpet and upholstery cleaners. (a) Definition. (1) Cleaning products formulated specifically for use in cleaning carpets and upholstery, through a dry or wet process, found...

  7. 7 CFR 2902.35 - Bathroom and spa cleaners.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Bathroom and spa cleaners. 2902.35 Section 2902.35... Items § 2902.35 Bathroom and spa cleaners. (a) Definition. Products that are designed to clean and/or prevent deposits on surfaces found in bathrooms and spas including, but not necessarily limited to,...

  8. 7 CFR 3201.65 - Concrete and asphalt cleaners.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Concrete and asphalt cleaners. 3201.65 Section 3201... PROCUREMENT Designated Items § 3201.65 Concrete and asphalt cleaners. (a) Definition. Chemicals used in concrete etching as well as to remove petroleum-based soils, lubricants, paints, mastics, organic...

  9. 7 CFR 3201.65 - Concrete and asphalt cleaners.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 15 2012-01-01 2012-01-01 false Concrete and asphalt cleaners. 3201.65 Section 3201... PROCUREMENT Designated Items § 3201.65 Concrete and asphalt cleaners. (a) Definition. Chemicals used in concrete etching as well as to remove petroleum-based soils, lubricants, paints, mastics, organic...

  10. 7 CFR 3201.65 - Concrete and asphalt cleaners.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Concrete and asphalt cleaners. 3201.65 Section 3201... PROCUREMENT Designated Items § 3201.65 Concrete and asphalt cleaners. (a) Definition. Chemicals used in concrete etching as well as to remove petroleum-based soils, lubricants, paints, mastics, organic...

  11. CLEANER-Hydrologic Observatory Joint Science Plan

    NASA Astrophysics Data System (ADS)

    Welty, C.; Dressler, K.; Hooper, R.

    2005-12-01

    The CLEANER-Hydrologic Observatory* initiative is a distributed network for research on complex environmental systems that focuses on the intersecting water-related issues of both the CUAHSI and CLEANER communities. It emphasizes research on the nation's water resources related to human-dominated natural and built environments. The network will be comprised of: interacting field sites with an integrated cyberinfrastructure; a centralized technical resource staff and management infrastructure to support interdisciplinary research through data collection from advanced sensor systems, data mining and aggregation from multiple sources and databases; cyber-tools for analysis, visualization, and predictive multi-scale modeling that is dynamically driven. As such, the network will transform 21st century workforce development in the water-related intersection of environmental science and engineering, as well as enable substantial educational and engagement opportunities for all age levels. The scientific goal and strategic intent of the CLEANER-Hydrologic Observatory Network is to transform our understanding of the earth's water cycle and associated biogeochemical cycles across spatial and temporal scales-enabling quantitative forecasts of critical water-related processes, especially those that affect and are affected by human activities. This strategy will develop scientific and engineering tools that will enable more effective adaptive approaches for resource management. The need for the network is based on three critical deficiencies in current abilities to understand large-scale environmental processes and thereby develop more effective management strategies. First we lack basic data and the infrastructure to collect them at the needed resolution. Second, we lack the means to integrate data across scales from different media (paper records, electronic worksheets, web-based) and sources (observations, experiments, simulations). Third, we lack sufficiently accurate

  12. Technical and economic analysis of energy efficiency of Chinese room air conditioners

    SciTech Connect

    Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

    2001-02-01

    China has experienced tremendous growth in the production and sales of room air conditioners over the last decade. Although minimum room air conditioner energy efficiency standards have been in effect since 1989, no efforts were made during most of the 1990's to update the standard to be more reflective of current market conditions. In 1999, China's State Bureau of Technical Supervision (SBTS) included in their annual plan the development and revision of the 1989 room air conditioner standard, and experts from SBTS worked together with LBNL to analyze the new standards. Based on the engineering and life cycle-cost analyses performed, the most predominant type of room air conditioner in the Chinese market (split-type with a cooling capacity between 2500 and 4500 W (8500 Btu/h and 15,300Btu/h)) can have its efficiency increased cost-effectively to an energy efficiency ratio (EER) of 2.92 W/W (9.9 Btu/hr/W). If an EER standard of 2.92 W/W became effective in 2001, Chinese consumers would be estimated to save over 3.5 billion Yuan (420 million U.S. dollars) over the period of 2001-2020. Carbon emissions over the same period would be reduced by approximately 12 million metric tonnes.

  13. Removal efficiencies of PCDDs/PCDFs by air pollution control devices in municipal solid waste incinerators.

    PubMed

    Kim, S C; Jeon, S H; Jung, I R; Kim, K H; Kwon, M H; Kim, J H; Yi, J H; Kim, S J; You, J C; Jung, D H

    2001-01-01

    Removal efficiencies of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDDs/PCDFs) by air pollution control devices (APCDs) in the commercial-scale municipal solid waste (MSW) incinerators with a capacity of above 200 ton/day were evaluated. The removal efficiencies of PCDDs/PCDFs were up to 95% when the activated carbon (AC) was injected in front of electrostatic precipitator (EP). Spray dryer absorber/bag filter (SDA/BF) had high removal efficiency (99%)) of PCDDs/PCDFs when a mixture of lime and AC was sprayed into the SDA. When the AC was not added in scrubbing solution, the whole congeners of PCDDs/PCDFs were enriched in the wet scrubber (WS) with negative removal efficiencies of -25% to -5731%. Discharge of PCDDs/PCDFs was decreased with increasing the proportions of AC added in scrubbing solution. Selective catalytic reduction (SCR) system had the removal efficiencies of up to 93% during the test operation.

  14. Materials Compatibility Testing in RSRM ODC: Free Cleaner Selection

    NASA Technical Reports Server (NTRS)

    Keen, Jill M.; Sagers, Neil W.; McCool, Alex (Technical Monitor)

    2001-01-01

    Government regulations have mandated production phase-outs of a number of solvents, including 1,1,1-trichloroethane, an ozone-depleting chemical (ODC). This solvent was used extensively in the production of the Reusable Solid Rocket Motors (RSRMs) for the Space Shuttle. Many tests have been performed to identify replacement cleaners. One major area of concern in the selection of a new cleaner has been compatibility. Some specific areas considered included cleaner compatibility with non-metallic surfaces, painted surfaces, support materials such as gloves and wipers as well as corrosive properties of the cleaners on the alloys used on these motors. The intent of this paper is to summarize the test logic, methodology, and results acquired from testing the many cleaner and material combinations.

  15. Flow Visualization Proposed for Vacuum Cleaner Nozzle Designs

    NASA Technical Reports Server (NTRS)

    2005-01-01

    In 1995, the NASA Lewis Research Center and the Kirby Company (a major vacuum cleaner company) began negotiations for a Space Act Agreement to conduct research, technology development, and testing involving the flow behavior of airborne particulate flow behavior. Through these research efforts, we hope to identify ways to improve suction, flow rate, and surface agitation characteristics of nozzles used in vacuum cleaner nozzles. We plan to apply an advanced visualization technology, known as Stereoscopic Imaging Velocimetry (SIV), to a Kirby G-4 vacuum cleaner. Resultant data will be analyzed with a high-speed digital motion analysis system. We also plan to evaluate alternative vacuum cleaner nozzle designs. The overall goal of this project is to quantify both velocity fields and particle trajectories throughout the vacuum cleaner nozzle to optimize its "cleanability"--its ability to disturb and remove embedded dirt and other particulates from carpeting or hard surfaces. Reference

  16. A review of Air Force high efficiency cascaded multiple bandgap solar cell research and development

    NASA Technical Reports Server (NTRS)

    Rahilly, W. P.

    1979-01-01

    At the time of their conception, the cell stack systems to be discussed represent the best semiconductor materials combinations to achieve Air Force program goals. These systems are investigated thoroughly and the most promising systems, from the standpoint of high efficiency, are taken for further development with large area emphasized (at least 4 sq cm). The emphasis in the Air Force cascaded cell program is placed on eventual nonconcentrator application. This use of the final cell design considerably relieves the low resistance requirements for the tunnel junction. In a high concentration application the voltage drop across the tunnel junction can be a very serious problem.

  17. Slip-Effect Functional Air Filter for Efficient Purification of PM2.5

    NASA Astrophysics Data System (ADS)

    Zhao, Xinglei; Wang, Shan; Yin, Xia; Yu, Jianyong; Ding, Bin

    2016-10-01

    Fabrication of air filtration materials (AFM) that allow air to easily flow through while retaining particles is a significant and urgent need due to the harmful airborne particulate matter pollution; however, this is still a challenging research area. Herein, we report novel slip-effect functional nanofibrous membranes with decreased air resistance (reduction rate of 40%) due to the slip flow of air molecules on the periphery of nanofibers. This was achieved through careful control over the diameters of electrospun polyacrylonitrile fibers and aperture size of fiber assembly. Fiber assembly with 86% of fiber diameters between 60–100 nm was found to be most effective for slip flow, as these diameters are close to the mean free path of air molecules (65.3 nm). Significantly, an equilibrium factor τ = df/d2 has been introduced to elucidate the effect of distance of adjacent fibers on the drag force of airflow. Furthermore, the most effective aperture size (>3.5 μm) for slip-effect has been determined. Ultimately, the new material displayed low air resistance of 29.5 Pa, high purification efficiency of 99.09%, good transmittance of 77%, and long service life. The successful fabrication of such materials can facilitate the development of high-performance AFMs for various applications.

  18. Slip-Effect Functional Air Filter for Efficient Purification of PM2.5

    PubMed Central

    Zhao, Xinglei; Wang, Shan; Yin, Xia; Yu, Jianyong; Ding, Bin

    2016-01-01

    Fabrication of air filtration materials (AFM) that allow air to easily flow through while retaining particles is a significant and urgent need due to the harmful airborne particulate matter pollution; however, this is still a challenging research area. Herein, we report novel slip-effect functional nanofibrous membranes with decreased air resistance (reduction rate of 40%) due to the slip flow of air molecules on the periphery of nanofibers. This was achieved through careful control over the diameters of electrospun polyacrylonitrile fibers and aperture size of fiber assembly. Fiber assembly with 86% of fiber diameters between 60–100 nm was found to be most effective for slip flow, as these diameters are close to the mean free path of air molecules (65.3 nm). Significantly, an equilibrium factor τ = df/d2 has been introduced to elucidate the effect of distance of adjacent fibers on the drag force of airflow. Furthermore, the most effective aperture size (>3.5 μm) for slip-effect has been determined. Ultimately, the new material displayed low air resistance of 29.5 Pa, high purification efficiency of 99.09%, good transmittance of 77%, and long service life. The successful fabrication of such materials can facilitate the development of high-performance AFMs for various applications. PMID:27748419

  19. The evolution of air resonance power efficiency in the violin and its ancestors

    PubMed Central

    Nia, Hadi T.; Jain, Ankita D.; Liu, Yuming; Alam, Mohammad-Reza; Barnas, Roman; Makris, Nicholas C.

    2015-01-01

    The fact that acoustic radiation from a violin at air-cavity resonance is monopolar and can be determined by pure volume change is used to help explain related aspects of violin design evolution. By determining the acoustic conductance of arbitrarily shaped sound holes, it is found that air flow at the perimeter rather than the broader sound-hole area dominates acoustic conductance, and coupling between compressible air within the violin and its elastic structure lowers the Helmholtz resonance frequency from that found for a corresponding rigid instrument by roughly a semitone. As a result of the former, it is found that as sound-hole geometry of the violin's ancestors slowly evolved over centuries from simple circles to complex f-holes, the ratio of inefficient, acoustically inactive to total sound-hole area was decimated, roughly doubling air-resonance power efficiency. F-hole length then slowly increased by roughly 30% across two centuries in the renowned workshops of Amati, Stradivari and Guarneri, favouring instruments with higher air-resonance power, through a corresponding power increase of roughly 60%. By evolution-rate analysis, these changes are found to be consistent with mutations arising within the range of accidental replication fluctuations from craftsmanship limitations with subsequent selection favouring instruments with higher air-resonance power. PMID:25792964

  20. Improving Energy Efficiency in Pharmaceutical ManufacturingOperations -- Part I: Motors, Drives and Compressed Air Systems

    SciTech Connect

    Galitsky, Christina; Chang, Sheng-chien; Worrell, Ernst; Masanet,Eric

    2006-04-01

    In Part I of this two-part series, we focus on efficient use of motors, drives and pumps, both for process equipment and compressed air systems. Pharmaceutical manufacturing plants in the U.S. spend nearly $1 billion each year for the fuel and electricity they need to keep their facilities running (Figure 1, below). That total that can increase dramatically when fuel supplies tighten and oil prices rise, as they did last year. Improving energy efficiency should be a strategic goal for any plant manager or manufacturing professional working in the drug industry today. Not only can energy efficiency reduce overall manufacturing costs, it usually reduces environmental emissions, establishing a strong foundation for a corporate greenhouse-gas-management program. For most pharmaceutical manufacturing plants, Heating, Ventilation and Air Conditioning (HVAC) is typically the largest consumer of energy, as shown in Table 1 below. This two-part series will examine energy use within pharmaceutical facilities, summarize best practices and examine potential savings and return on investment. In this first article, we will focus on efficient use of motors, drives and pumps, both for process equipment and compressed air systems. Part 2, to be published in May, will focus on overall HVAC systems, building management and boilers.

  1. Increasing round trip efficiency of hybrid Li-air battery with bifunctional catalysts

    SciTech Connect

    Huang, K; Li, YF; Xing, YC

    2013-07-30

    Previously it was shown that Pt as cathode catalyst ha's a large overpotential during charge in rechargeable hybrid Li-air battery with sulfuric acid catholyte. This article demonstrates that a bifunctional catalyst composed of Pt and IrO2 supported on carbon nanotubes can address this problem. The specially designed and synthesized bifunctional catalyst showed significant overpotential reduction and achieved a round trip energy efficiency of 81% after 10 cycles, higher than many achieved in aprotic Li-O-2 batteries. The hybrid Li-air battery was discharged and recharged for 20 cycles at 0.2 mA/cm(2), showing a fairly stable cell performance. A specific capacity of 306 mAh/g and a specific energy of 1110 Wh/kg were obtained for the hybrid Li-air battery in terms of acid weight. (c) 2013 Elsevier Ltd. All rights reserved.

  2. Efficiencies for production of nitrogen oxides by proton impact in air

    NASA Astrophysics Data System (ADS)

    Rahman, Mahbubur; Cooray, Vernon; Possnert, Göran

    2013-03-01

    We present the first laboratory measurements of nitrogen oxides generated by proton impact in air. Experiments were conducted at the Tandem Laboratory of Uppsala University. A proton beam with known current and energy was injected into an air tight ionising chamber for a fixed time duration and the resulting nitrogen oxides were measured by the method of chemiluminescence. The data are presented in terms of number of produced NOX (NO+NO2) molecules for different proton energy, proton beam current and duration. The efficiency for NOX production by proton impact in air can on average be estimated to about 0.2 NOX molecules per ion-pair based on 1 cm diameter proton beam with energies from 2 to 4 MeV and varied currents from 0.1 to 10 nA.

  3. Carbon Dioxide and Ionic Liquid Refrigerants: Compact, Efficient Air Conditioning with Ionic Liquid-Based Refrigerants

    SciTech Connect

    2010-10-01

    BEETIT Project: Notre Dame is developing an air-conditioning system with a new ionic liquid and CO2 as the working fluid. Synthetic refrigerants used in air conditioning and refrigeration systems are potent GHGs and can trap 1,000 times more heat in the atmosphere than CO2 alone—making CO2 an attractive alternative for synthetic refrigerants in cooling systems. However, operating cooling systems with pure CO2 requires prohibitively high pressures and expensive hardware. Notre Dame is creating a new fluid made of CO2 and ionic liquid that enables the use of CO2 at low pressures and requires minimal changes to existing hardware and production lines. This new fluid also produces no harmful emissions and can improve the efficiency of air conditioning systems— enabling new use of CO2 as a refrigerant in cooling systems.

  4. Numerical simulation of effective efficiency of a discrete multi V-pattern rib solar air channel

    NASA Astrophysics Data System (ADS)

    Kumar, Anil; Saini, R. P.; Saini, J. S.

    2016-10-01

    The use of artificial roughness in the form of repeated ribs has been found to be an efficient method of improving the heat transfer to fluid flowing in the channel. In this study, performance of solar air channel as a function of discrete multi V-pattern rib shapes has been investigated. The e/D was varied from 0.022 to 0.043, Gd/Lv was varied from 0.24 to 0.80, g/e was varied from 0.5 to 1.5, α was varied from 30° to 75°, P/e was varied from 6.0 to 12.0 and W/w was varied from 1.0 to 10.0. A methodology has been developed for the prediction of effective efficiency. Based on the values of effective efficiency, an optimization has been carried out to determine the set of data of roughness shapes parameters that correspond to better effective efficiency for given values of operating parameters of the air channel. Design plots have been represent to depict the data of individual roughness shapes parameters that characterize the optimum condition as a function of performance parameter and intensity of radiation. It was observed that the maximum values of effective efficiency for e/D of 0.043, Gd/Lv of 0.69, g/e of 1.0, α of 60°, P/e of 8.0 and W/w of 6.0. Discrete multi v-rib shape has been found to be better thermohydraulic performance (effective efficiency) as comparison to other rib shapes solar air channels.

  5. An experimental quantification of the NOX production efficiency of energetic alpha particles in air

    NASA Astrophysics Data System (ADS)

    Rahman, Mahbubur; Cooray, Vernon; Possnert, Göran; Nyberg, Johan

    2006-07-01

    An experimental study on the production of NOX by alpha particles impact in air at atmospheric pressure is presented. A mixed radioactive source of 208Po and 209Po with an integrated activity of 9.6 MBq over a solid angle of 2π and an average alpha particle energy of 4.5 MeV was used for ionization of atmospheric air in an airtight chamber and the NOX production was measured by the chemiluminescence method. The NOX production rate is found to be about 1.2 NOX molecules per ion-pair. The NOX production efficiency per Joule of dissipated energy is calculated to be 20×1016 NOX molecules per Joule. This efficiency is comparable to that of hot laboratory sparks discharges.

  6. An efficient new automobile air-conditioning system based on CO{sub 2} vapor compression

    SciTech Connect

    Pettersen, J.

    1994-12-31

    A new, efficient, and environmentally safe automobile air-conditioning system based on carbon dioxide (CO{sub 2}) vapor compression has been developed. Although working pressures and component design are different, the basic principles are similar to those of current chlorofluorocarbon/hydrofluorocarbon (CFC/HFC) units. With the construction and testing of a laboratory prototype, it has been documented that the new system is highly competitive with current CFC-12 and HFC-134a units in terms of efficiency, capacity, cost, weight, and dimensions. The CO{sub 2} concept thus offers a solution to the environmental problem associated with automobile air conditioning and eliminates all uncertainties with respect to possible unforeseen effects from new refrigerant compounds. Further advantages of the natural fluid CO{sub 2} as a refrigerant are: no need for recycling or recovery, low cost of fluid, excellent availability, well-known properties, and more compact machinery and components.

  7. Effects of air tightness of the building envelope as witnessed through an energy efficiency retrofit program

    NASA Astrophysics Data System (ADS)

    Ryzak, Adam

    Air leakage through the building envelope has been identified as a major factor affecting the energy consumption of buildings. This study explored homes located in Central Indiana that were recipients of government-sponsored grants to perform energy efficient upgrades. To combat the issue of air leakage, many homes were retrofitted with air sealing packages. A certified energy auditor performed before and after blower door tests to measure the air leakage of each home. An analysis of the 63 homes measured resulted in the conclusion that the overall improvement in blower door test results was greater than 20%. In addition to blower door tests, the energy auditor inspected each home and generated a list of recommended energy efficient upgrades (within the scope of the grant) as well as their respective installation costs. An analysis was performed investigating the auditor's accuracy at estimating these costs. Based on data from 33 homes, the conclusion was made that the energy auditor was not proficient in the role of a construction estimator. The disparity between estimated and actual costs was not within the 10-15% target range.

  8. Tuning efficiency and linewidth of electrostatically actuated multiple air-gap filters

    NASA Astrophysics Data System (ADS)

    Römer, F.; Prott, C.; Irmer, S.; Daleiden, J.; Tarraf, A.; Hillmer, H.; Strassner, M.

    2003-01-01

    We investigated the tuning efficiency of electrostatically actuated multiple air-gap filters fabricated in InP for dense wavelength division multiplex applications by comparing measured tuning curves with the results of optical and mechanical simulations. These filters exhibit a record tuning range of 127 nm at 7.3 V tuning voltage. The filters were measured in reflection using standard single mode fiber. The subsequent analysis is based on a one-dimensional electromechanical and optical model providing a reasonable estimation for the pull-in voltage. Optical simulations show that the filter linewidth does not affect the tuning efficiency.

  9. Development of a high-efficiency, high-performance air filter medium

    NASA Astrophysics Data System (ADS)

    Bergman, W.; Sawyer, S. R.

    1988-08-01

    A unique high-efficiency particulate air (HEPA) filter medium has been developed for applications in high temperature and high pressure environments. This filter medium is a composite made from quartz and stainless-steel fibers that have been sintered together. The composite medium has the same efficiency and pressure drop as standard HEPA glass media, but has four times the tensile strength and can operate continuously at temperatures up to 500 C. In a conventional HEPA, the binder burns out above 250 C and the medium loses its strength; our composite filter medium has no comparable loss of strength even at 500 C.

  10. Air fluorescence efficiency measurements for AIRWATCH based mission: Experimental set-up

    SciTech Connect

    Biondo, B.; Catalano, O.; Celi, F.; Fazio, G.; Giarrusso, S.; La Rosa, G.; Mangano, A.; Bonanno, G.; Cosentino, R.; Di Benedetto, R.; Scuderi, S.; Richiusa, G.; Gregorio, A.

    1998-06-15

    In the framework of the AIRWATCH project we present an experimental set-up to measure the efficiency of the UV fluorescence production of the air using hard X-ray stimulus. The measures will be carried out at different pressure and temperature to emulate the same condition of the upper layers of the atmosphere where X-ray and gamma ray photons of Gamma Ray Bursts are absorbed.

  11. Increased Efficiency in SI Engine with Air Replaced by Oxygen in Argon Mixture

    SciTech Connect

    Killingsworth, N J; Rapp, V H; Flowers, D L; Aceves, S M; Chen, J; Dibble, R

    2010-01-13

    Basic engine thermodynamics predicts that spark ignited engine efficiency is a function of both the compression ratio of the engine and the specific heat ratio of the working fluid. In practice the compression ratio of the engine is often limited due to knock. Both higher specific heat ratio and higher compression ratio lead to higher end gas temperatures and increase the likelihood of knock. In actual engine cycles, heat transfer losses increase at higher compression ratios and limit efficiency even when the knock limit is not reached. In this paper we investigate the role of both the compression ratio and the specific heat ratio on engine efficiency by conducting experiments comparing operation of a single-cylinder variable-compression-ratio engine with both hydrogen-air and hydrogen-oxygen-argon mixtures. For low load operation it is found that the hydrogen-oxygen-argon mixtures result in higher indicated thermal efficiencies. Peak efficiency for the hydrogen-oxygen-argon mixtures is found at compression ratio 5.5 whereas for the hydrogen-air mixture with an equivalence ratio of 0.24 the peak efficiency is found at compression ratio 13. We apply a three-zone model to help explain the effects of specific heat ratio and compression ratio on efficiency. Operation with hydrogen-oxygen-argon mixtures at low loads is more efficient because the lower compression ratio results in a substantially larger portion of the gas to reside in the adiabatic core rather than in the boundary layer and in the crevices, leading to less heat transfer and more complete combustion.

  12. Energy Efficiency in Buildings as an Air Quality Compliance Approach: Opportunities for the U.S. Department of Energy

    SciTech Connect

    Vine, Edward

    2002-05-01

    Increasing the energy efficiency of end-use equipment in the residential, commercial, and industrial sectors can reduce air pollution emissions and greenhouse gases significantly. Because energy efficiency is an effective means of reducing multi-pollutant emissions, it is important to ensure that energy efficiency is a fully engaged component of emission-reduction programs. However, while energy-efficiency measures are perceived by many stakeholders to be important options for improving air quality, some members in the air quality community are concerned about the ability of these measures to fit in a regulatory framework-in particular, the ability of emissions reductions from energy-efficiency measures to be real, quantifiable, certifiable, and enforceable. Hence, there are few air quality programs that include energy efficiency as a tool for complying with air quality regulations. This paper describes the connection between energy consumption and air quality, the potential role of energy-efficiency measures to meet air quality regulations, the barriers and challenges to the use of these measures in the air quality regulatory environment, and the potential role that the U.S. Department of Energy's (USDOE) Energy Efficiency and Renewable Energy's Building Technology, State and Community Programs (EERE-Buildings) could play in this area. EERE-Buildings can play a very important role in promoting energy efficiency in the air quality community, in ways that are fully consistent with its overall mission. EERE-Buildings will need to work with other stakeholders to aggressively promote energy efficiency via multiple means: publications, analytical tools, pilot programs, demonstrations, and program and policy analysis and evaluation. EERE-Buildings and state energy officials have considerable experience in implementing and monitoring energy-savings projects, as well as in designing documentation and verification requirements of energy-efficiency improvements. The

  13. Improving Best Air Conditioner Efficiency by 20-30% through a High Efficiency Fan and Diffuser Stage Coupled with an Evaporative Condenser Pre-Cooler

    SciTech Connect

    Parker, Danny S; Sherwin, John R; Raustad, Richard

    2014-04-10

    The Florida Solar Energy Center (FSEC) conducted a research project to improve the best residential air conditioner condenser technology currently available on the market by retrofitting a commercially-available unit with both a high efficiency fan system and an evaporative pre-cooler. The objective was to integrate these two concepts to achieve an ultra-efficient residential air conditioner design. The project produced a working prototype that was 30% more efficient compared to the best currently-available technologies; the peak the energy efficiency ratio (EER) was improved by 41%. Efficiency at the Air-Conditioning and Refrigeration Institute (ARI) standard B-condition which is used to estimate seasonal energy efficiency ratio (SEER), was raised from a nominal 21 Btu/Wh to 32 Btu/Wh.

  14. Beyond symbiosis: cleaner shrimp clean up in culture.

    PubMed

    Militz, Thane A; Hutson, Kate S

    2015-01-01

    Cleaner organisms exhibit a remarkable natural behaviour where they consume ectoparasites attached to "client" organisms. While this behaviour can be utilized as a natural method of parasitic disease control (or biocontrol), it is not known whether cleaner organisms can also limit reinfection from parasite eggs and larvae within the environment. Here we show that cleaner shrimp, Lysmata amboinensis, consume eggs and larvae of a harmful monogenean parasite, Neobenedenia sp., in aquaculture. Shrimp consumed parasite eggs under diurnal (63%) and nocturnal (14%) conditions as well as infectious larvae (oncomiracidia) diurnally (26%). Furthermore, we trialled the inclusion of cleaner shrimp for preventative parasite management of ornamental fish, Pseudanthias squamipinnis, and found shrimp reduced oncomiracidia infection success of host fish by half compared to controls (held without shrimp). Fish held without cleaner shrimp exhibited pigmentation changes as a result of infection, possibly indicative of a stress response. These results provide the first empirical evidence that cleaner organisms reduce parasite loads in the environment through non-symbiotic cleaning activities. Our research findings have relevance to aquaculture and the marine ornamental trade, where cleaner shrimp could be applied for prophylaxis and control of ectoparasite infections. PMID:25706952

  15. Beyond Symbiosis: Cleaner Shrimp Clean Up in Culture

    PubMed Central

    Militz, Thane A.; Hutson, Kate S.

    2015-01-01

    Cleaner organisms exhibit a remarkable natural behaviour where they consume ectoparasites attached to “client” organisms. While this behaviour can be utilized as a natural method of parasitic disease control (or biocontrol), it is not known whether cleaner organisms can also limit reinfection from parasite eggs and larvae within the environment. Here we show that cleaner shrimp, Lysmata amboinensis, consume eggs and larvae of a harmful monogenean parasite, Neobenedenia sp., in aquaculture. Shrimp consumed parasite eggs under diurnal (63%) and nocturnal (14%) conditions as well as infectious larvae (oncomiracidia) diurnally (26%). Furthermore, we trialled the inclusion of cleaner shrimp for preventative parasite management of ornamental fish, Pseudanthias squamipinnis, and found shrimp reduced oncomiracidia infection success of host fish by half compared to controls (held without shrimp). Fish held without cleaner shrimp exhibited pigmentation changes as a result of infection, possibly indicative of a stress response. These results provide the first empirical evidence that cleaner organisms reduce parasite loads in the environment through non-symbiotic cleaning activities. Our research findings have relevance to aquaculture and the marine ornamental trade, where cleaner shrimp could be applied for prophylaxis and control of ectoparasite infections. PMID:25706952

  16. Beyond symbiosis: cleaner shrimp clean up in culture.

    PubMed

    Militz, Thane A; Hutson, Kate S

    2015-01-01

    Cleaner organisms exhibit a remarkable natural behaviour where they consume ectoparasites attached to "client" organisms. While this behaviour can be utilized as a natural method of parasitic disease control (or biocontrol), it is not known whether cleaner organisms can also limit reinfection from parasite eggs and larvae within the environment. Here we show that cleaner shrimp, Lysmata amboinensis, consume eggs and larvae of a harmful monogenean parasite, Neobenedenia sp., in aquaculture. Shrimp consumed parasite eggs under diurnal (63%) and nocturnal (14%) conditions as well as infectious larvae (oncomiracidia) diurnally (26%). Furthermore, we trialled the inclusion of cleaner shrimp for preventative parasite management of ornamental fish, Pseudanthias squamipinnis, and found shrimp reduced oncomiracidia infection success of host fish by half compared to controls (held without shrimp). Fish held without cleaner shrimp exhibited pigmentation changes as a result of infection, possibly indicative of a stress response. These results provide the first empirical evidence that cleaner organisms reduce parasite loads in the environment through non-symbiotic cleaning activities. Our research findings have relevance to aquaculture and the marine ornamental trade, where cleaner shrimp could be applied for prophylaxis and control of ectoparasite infections.

  17. Use of GC/MS and Microtome Techniques as Methods to Evaluate ODC Free Cleaner Diffusion and Evaporation in Insulation and Phenolic Case Material

    NASA Technical Reports Server (NTRS)

    Biegert, L. L.

    2001-01-01

    Because of the 1990 Clean Air Act Amendment (CAAA) many chlorinated solvents used in the aerospace industry are being phased out. Replacement of the ODC (ozone-depleting chemicals) with less volatile, non-ozone depleting cleaners has been extensively studied over the past seven years at Thiokol Propulsion, a Division of Cordant Technologies, Inc. The down selection of ODC replacement cleaners has been based on several factors including the diffusion evaporation of the cleaners in selected substrates. Methodologies were developed to evaluate the cleaner content in substrates. Methods of cutting thin slices of material (microtoming) were combined with GC/MS (gas chromatography/mass spectroscopy) analysis. Substrates evaluated in this study include potential solid rocket motor materials: ASNBR (asbestos-filled nitrile butadiene rubber) and CFEPDM (carbon-filled ethylene propylene dimonomer) insulation and glass (GCP), carbon (CCP) and silica (SCP) cloth phenolic substrates with fibers either parallel (0 deg) or perpendicular (90 deg) to the surface. Residue profiles indicate both cleaner and substrate composition affect the diffusion and subsequent evaporation of the cleaner from the substrate surface.

  18. Cleaner wrasse influence habitat selection of young damselfish

    NASA Astrophysics Data System (ADS)

    Sun, D.; Cheney, K. L.; Werminghausen, J.; McClure, E. C.; Meekan, M. G.; McCormick, M. I.; Cribb, T. H.; Grutter, A. S.

    2016-06-01

    The presence of bluestreak cleaner wrasse, Labroides dimidiatus, on coral reefs increases total abundance and biodiversity of reef fishes. The mechanism(s) that cause such shifts in population structure are unclear, but it is possible that young fish preferentially settle into microhabitats where cleaner wrasse are present. As a first step to investigate this possibility, we conducted aquarium experiments to examine whether settlement-stage and young juveniles of ambon damselfish, Pomacentrus amboinensis, selected a microhabitat near a cleaner wrasse (adult or juvenile). Both settlement-stage (0 d post-settlement) and juvenile (~5 weeks post-settlement) fish spent a greater proportion of time in a microhabitat adjacent to L. dimidiatus than in one next to a control fish (a non-cleaner wrasse, Halichoeres melanurus) or one where no fish was present. This suggests that cleaner wrasse may serve as a positive cue during microhabitat selection. We also conducted focal observations of cleaner wrasse and counts of nearby damselfishes (1 m radius) to examine whether newly settled fish obtained direct benefits, in the form of cleaning services, from being near a cleaner wrasse. Although abundant, newly settled recruits (<20 mm total length) were rarely (2 %) observed being cleaned in 20 min observations compared with larger damselfishes (58 %). Individual damselfish that were cleaned were significantly larger than the median size of the surrounding nearby non-cleaned conspecifics; this was consistent across four species. The selection by settlement-stage fish of a microhabitat adjacent to cleaner wrasse in the laboratory, despite only being rarely cleaned in the natural environment, suggests that even rare cleaning events and/or indirect benefits may drive their settlement choices. This behaviour may also explain the decreased abundance of young fishes on reefs from which cleaner wrasse had been experimentally removed. This study reinforces the potentially important role of

  19. Evaluation of alternative cleaners for solder flux and mold release removal

    SciTech Connect

    Lopez, E.P.; Peebles, D.E.; Reich, J.E.; Smith, M.E.

    1991-01-01

    As part of a solvent substitution program, an evaluation of selected alternative cleaners for solder flux and mold release removal has been performed. Six cleaners were evaluated for their efficiency in removing a rosin mildly activated flux and a silicone mold release from copper, 17-4PH stainless steel, polyimide quartz glass and tin-lead surfaces. A parallel effort also studied deionized water removal of organic acid fluxes. Auger electron spectroscopy and X-ray photoelectron spectroscopy were used to determine relative elemental cleanliness of the outermost atomic layers. An Omega Meter Test was used to measure residual ionic contamination. Water drop contact angles were used to measure the effectiveness of silicone removal from Cu substrates. In most cases, the cleanliness levels were good to excellent. 10 refs., 8 figs., 19 tabs.

  20. Ozone Generators That Are Sold as Air Cleaners

    MedlinePlus

    ... possible even when a user follows the manufacturer’s operating instructions . There are many brands and models of ... suggests that users err on the side of operating a more powerful machine than would normally be ...

  1. High efficiency air stable organic photovoltaics with an aqueous inorganic contact

    NASA Astrophysics Data System (ADS)

    Jayawardena, K. D. G. Imalka; Li, Siying; Sam, Laurent F.; Smith, Christopher T. G.; Beliatis, Michail J.; Gandhi, Keyur K.; Prabhath, M. R. Ranga; Pozegic, Thomas R.; Chen, Sujie; Xu, Xiaoli; Dabera, G. Dinesha M. R.; Rozanski, Lynn J.; Sporea, Radu A.; Mills, Christopher A.; Guo, Xiaojun; Silva, S. Ravi P.

    2015-08-01

    We report a ZnO interfacial layer based on an environmentally friendly aqueous precursor for organic photovoltaics. Inverted PCDTBT devices based on this precursor show power conversion efficiencies of 6.8-7%. Unencapsulated devices stored in air display prolonged lifetimes extending over 200 hours with less than 20% drop in efficiency compared to devices based on the standard architecture.We report a ZnO interfacial layer based on an environmentally friendly aqueous precursor for organic photovoltaics. Inverted PCDTBT devices based on this precursor show power conversion efficiencies of 6.8-7%. Unencapsulated devices stored in air display prolonged lifetimes extending over 200 hours with less than 20% drop in efficiency compared to devices based on the standard architecture. Electronic supplementary information (ESI) available: Experimental methods, performance of standard architecture, inverted architecture with TiOx interlayer, onset of s-curves for the standard architecture, photoluminescence of the ZnO film, field effect characteristics of the ZnO thin films, thermogravimetric analysis of ZnO. See DOI: 10.1039/c5nr01239b

  2. Statistical estimate of mercury removal efficiencies for air pollution control devices of municipal solid waste incinerators.

    PubMed

    Takahashi, Fumitake; Kida, Akiko; Shimaoka, Takayuki

    2010-10-15

    Although representative removal efficiencies of gaseous mercury for air pollution control devices (APCDs) are important to prepare more reliable atmospheric emission inventories of mercury, they have been still uncertain because they depend sensitively on many factors like the type of APCDs, gas temperature, and mercury speciation. In this study, representative removal efficiencies of gaseous mercury for several types of APCDs of municipal solid waste incineration (MSWI) were offered using a statistical method. 534 data of mercury removal efficiencies for APCDs used in MSWI were collected. APCDs were categorized as fixed-bed absorber (FA), wet scrubber (WS), electrostatic precipitator (ESP), and fabric filter (FF), and their hybrid systems. Data series of all APCD types had Gaussian log-normality. The average removal efficiency with a 95% confidence interval for each APCD was estimated. The FA, WS, and FF with carbon and/or dry sorbent injection systems had 75% to 82% average removal efficiencies. On the other hand, the ESP with/without dry sorbent injection had lower removal efficiencies of up to 22%. The type of dry sorbent injection in the FF system, dry or semi-dry, did not make more than 1% difference to the removal efficiency. The injection of activated carbon and carbon-containing fly ash in the FF system made less than 3% difference. Estimation errors of removal efficiency were especially high for the ESP. The national average of removal efficiency of APCDs in Japanese MSWI plants was estimated on the basis of incineration capacity. Owing to the replacement of old APCDs for dioxin control, the national average removal efficiency increased from 34.5% in 1991 to 92.5% in 2003. This resulted in an additional reduction of about 0.86Mg emission in 2003. Further study using the methodology in this study to other important emission sources like coal-fired power plants will contribute to better emission inventories.

  3. Air filtration in the free molecular flow regime: a review of high-efficiency particulate air filters based on carbon nanotubes.

    PubMed

    Li, Peng; Wang, Chunya; Zhang, Yingying; Wei, Fei

    2014-11-01

    Air filtration in the free molecular flow (FMF) regime is important and challenging because a higher filtration efficiency and lower pressure drop are obtained when the fiber diameter is smaller than the gas mean free path in the FMF regime. In previous studies, FMF conditions have been obtained by increasing the gas mean free path through reducing the pressure and increasing the temperature. In the case of carbon nanotubes (CNTs) with nanoscale diameters, it is possible to filtrate in the FMF regime under normal conditions. This paper reviews recent progress in theoretical and experimental studies of air filtration in the FMF regime. Typical structure models of high-efficiency particulate (HEPA) air filters based on CNTs are introduced. The pressure drop in air filters operated in the FMF regime is less than that predicted by the conventional air filtration theory. The thinnest HEPA filters fabricated from single-walled CNT films have an extremely low pressure drop. CNT air filters with a gradient nanostructure are shown to give a much better filtration performance in dynamic filtration. CNT air filters with a hierarchical structure and an agglomerated CNT fluidized bed air filter are also introduced. Finally, the challenges and opportunities for the application of CNTs in air filtration are discussed.

  4. Air filtration in the free molecular flow regime: a review of high-efficiency particulate air filters based on carbon nanotubes.

    PubMed

    Li, Peng; Wang, Chunya; Zhang, Yingying; Wei, Fei

    2014-11-01

    Air filtration in the free molecular flow (FMF) regime is important and challenging because a higher filtration efficiency and lower pressure drop are obtained when the fiber diameter is smaller than the gas mean free path in the FMF regime. In previous studies, FMF conditions have been obtained by increasing the gas mean free path through reducing the pressure and increasing the temperature. In the case of carbon nanotubes (CNTs) with nanoscale diameters, it is possible to filtrate in the FMF regime under normal conditions. This paper reviews recent progress in theoretical and experimental studies of air filtration in the FMF regime. Typical structure models of high-efficiency particulate (HEPA) air filters based on CNTs are introduced. The pressure drop in air filters operated in the FMF regime is less than that predicted by the conventional air filtration theory. The thinnest HEPA filters fabricated from single-walled CNT films have an extremely low pressure drop. CNT air filters with a gradient nanostructure are shown to give a much better filtration performance in dynamic filtration. CNT air filters with a hierarchical structure and an agglomerated CNT fluidized bed air filter are also introduced. Finally, the challenges and opportunities for the application of CNTs in air filtration are discussed. PMID:25288476

  5. Efficient and reusable polyamide-56 nanofiber/nets membrane with bimodal structures for air filtration.

    PubMed

    Liu, Bowen; Zhang, Shichao; Wang, Xueli; Yu, Jianyong; Ding, Bin

    2015-11-01

    Nanofibrous media that both possess high airborne particle interception efficiency and robust air permeability would have broad technological implications for areas ranging from individual protection and industrial security to environmental governance; however, creating such filtration media has proved extremely challenging. Here we report a strategy to construct the bio-based polyamide-56 nanofiber/nets (PA-56 NFN) membranes with bimodal structures for effective air filtration via one-step electrospinning/netting. The PA-56 membranes are composed of completely covered two-dimensional (2D) ultrathin (∼20 nm) nanonets which are optimized by facilely regulating the solution concentration, and the bonded scaffold fibers constructed cavity structures which are synchronously created by using the CH3COOH inspiration. With integrated properties of small aperture, high porosity, and bonded scaffold, the resulting PA-56 NFN membranes exhibit high filtration efficiency of 99.995%, low pressure drop of 111 Pa, combined with large dust holding capacity of 49 g/m(2) and dust-cleaning regeneration ability, for filtrating ultrafine airborne particles in the most safe manner involving sieving principle and surface filtration. The successful synthesis of PA-56 NFN medium would not only make it a promising candidate for air filtration, but also provide new insights into the design and development of nanonet-based bimodal structures for various applications. PMID:26188726

  6. Efficient and reusable polyamide-56 nanofiber/nets membrane with bimodal structures for air filtration.

    PubMed

    Liu, Bowen; Zhang, Shichao; Wang, Xueli; Yu, Jianyong; Ding, Bin

    2015-11-01

    Nanofibrous media that both possess high airborne particle interception efficiency and robust air permeability would have broad technological implications for areas ranging from individual protection and industrial security to environmental governance; however, creating such filtration media has proved extremely challenging. Here we report a strategy to construct the bio-based polyamide-56 nanofiber/nets (PA-56 NFN) membranes with bimodal structures for effective air filtration via one-step electrospinning/netting. The PA-56 membranes are composed of completely covered two-dimensional (2D) ultrathin (∼20 nm) nanonets which are optimized by facilely regulating the solution concentration, and the bonded scaffold fibers constructed cavity structures which are synchronously created by using the CH3COOH inspiration. With integrated properties of small aperture, high porosity, and bonded scaffold, the resulting PA-56 NFN membranes exhibit high filtration efficiency of 99.995%, low pressure drop of 111 Pa, combined with large dust holding capacity of 49 g/m(2) and dust-cleaning regeneration ability, for filtrating ultrafine airborne particles in the most safe manner involving sieving principle and surface filtration. The successful synthesis of PA-56 NFN medium would not only make it a promising candidate for air filtration, but also provide new insights into the design and development of nanonet-based bimodal structures for various applications.

  7. Field Measurements of Heating Efficiency of Electric Forced-Air Furnaces in Six Manufactured Homes.

    SciTech Connect

    Davis, Bob; Palmiter, Larry S.; Siegel, Jeff

    1994-07-26

    This report presents the results of field measurements of heating efficiency for six manufactured homes in the Pacific Northwest heated with electric forced-air systems. This is the first in a series of regional and national efforts to measure in detail the heating efficiency of manufactured homes. Only six homes were included in this study because of budgetary constraints; therefore this is not a representative sample. These investigations do provide some useful information on the heating efficiency of these homes. Useful comparisons can be drawn between these study homes and site-built heating efficiencies measured with a similar protocol. The protocol used to test these homes is very similar to another Ecotope protocol used in the study conducted in 1992 and 1993 for the Bonneville Power Administration to test the heating efficiency of 24 homes. This protocol combined real-time power measurements of furnace energy usage with energy usage during co-heat periods. Accessory data such as house and duct tightness measurements and tracer gas measurements were used to describe these homes and their heating system efficiency. Ensuring that manufactured housing is constructed in an energy and resource efficient manner is of increasing concern to manufactured home builders and consumers. No comparable work has been done to measure the heating system efficiency of MCS manufactured homes, although some co-heat tests have been performed on manufactured homes heated with natural gas to validate HUD thermal standards. It is expected that later in 1994 more research of this kind will be conducted, and perhaps a less costly and less time-consuming method for testing efficiencies will be develops.

  8. Soy-Protein-Based Nanofabrics for Highly Efficient and Multifunctional Air Filtration.

    PubMed

    Souzandeh, Hamid; Johnson, Kyle S; Wang, Yu; Bhamidipaty, Keshava; Zhong, Wei-Hong

    2016-08-10

    Proteins are well-known by their numerous active functional groups along the polypeptide chain. The variety of functional groups of proteins provides a great potential for proteins to interact with airborne pollutants with varying surface properties. However, to our knowledge, a successful demonstration of this potential has not been reported before. In this work, soy protein, a type of abundant plant protein, has been employed for the first time to fabricate multifunctional air-filtration materials. To take advantage of the functional groups of soy protein for air filtration, the soy protein was first well denatured to unfold the polypeptide chains and then fabricated into nanofibers with the help of poly(vinyl alcohol). It was found that the resultant nanofabrics showed high filtration efficiency not only for airborne particulates with a broad range of size but also for various toxic gaseous chemicals (e.g., formaldehyde and carbon monoxide), a capability that has not been realized by conventional air-filtering materials. This study indicates that protein-based nanofabrics are promising nanomaterials for multifunctional air-filtration applications.

  9. Improving Energy Efficiency of Compressed Air System Based onSystem Audit

    SciTech Connect

    Shanghai, Hongbo Qin; McKane, Aimee

    2007-06-01

    Industrial electric motor systems consume more than 600billion kWh annually, accounting for more than 50 percent of China selectricity use. The International Energy Agency estimates thatoptimizing motor systems results in an improvement of 20-25 percent,which is well-supported by experience in both the U.S. and China.Compressed air systems in China use 9.4 percent of all electricity.Compressed air use in China is growing rapidly, as new industrial plantsare built and the production processes of existing plants expand andchange. Most of these systems, whether existing or new, are not optimizedfor energy efficiency. This paper will present a practitioner'sperspective on theemergence of compressed air auditing services inChina, specifically as it pertains to Shanghai and surrounding areas.Both the methodology used and the market development of these compressedair system services will be addressed. Finally, the potential for energysaving opportunities will be described based on highlights from over 50compressed air system energy audits completed by Shanghai EnergyConservation Service Center, both during the United Nations IndustrialDevelopment Organization (UNIDO) China Motor System Energy ConservationProgram, and after this training program was completed.

  10. Study on an Efficient Dehumidifying Air-conditioning System utilizing Phase Change of Intermediate Pressure Refrigerant

    NASA Astrophysics Data System (ADS)

    Maeda, Kensaku; Inaba, Hideo

    The present study has proven a new dehumidifying system that aimed to reduce the sensible heat factor(SHF) of cooling process without using additional heat to relieve the internationally indicated conflict between energy saving and dehumidification necessary for keeping adequate indoor air quality (IAQ). In this system, we used intermediate pressure refrigerant in a vapor compression refrigerating cycle as heat transfer medium of a characteristic heat exchanger to precool the process air entering into an evaporator as well as to reheat the process air leaving from the evaporator. By this system, the present results achieved higher moisture removal and consequently higher efficiency of dehumidifying process. In addition to this fact, since this system has capability of integration into air-conditioning apparatus(HVAC system), it will be able to work for wide range of cooling load by variable SHF function. In the present paper, technical information, experimental results, and simulation results which assumed to apply this system into HVAC system are reported.

  11. New efficient ligand for sub-mol % copper-catalyzed C-N cross-coupling reactions running under air.

    PubMed

    Larsson, Per-Fredrik; Astvik, Peter; Norrby, Per-Ola

    2012-01-01

    A new efficient ligand, N,N''-dimethyldiethylene triamine (DMDETA), has been synthesized and evaluated for sub-mol % copper-catalyzed C-N cross-coupling reactions. The efficiency of the ligand was determined by kinetic methods. DMDETA proved to display efficiency similar to DMEDA and, in addition, the resulting catalyst was tolerant to air. PMID:23209530

  12. New efficient ligand for sub-mol % copper-catalyzed C–N cross-coupling reactions running under air

    PubMed Central

    Larsson, Per-Fredrik; Astvik, Peter

    2012-01-01

    Summary A new efficient ligand, N,N’’-dimethyldiethylene triamine (DMDETA), has been synthesized and evaluated for sub-mol % copper-catalyzed C–N cross-coupling reactions. The efficiency of the ligand was determined by kinetic methods. DMDETA proved to display efficiency similar to DMEDA and, in addition, the resulting catalyst was tolerant to air. PMID:23209530

  13. 16. INTERIOR VIEW, BASEMENT, LOOKING NORTHWEST AT 'SMUT MILL' CLEANER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. INTERIOR VIEW, BASEMENT, LOOKING NORTHWEST AT 'SMUT MILL'- CLEANER FOR BUCKWHEAT, AND GRAIN CHUTES. GRAIN ELEVATOR TURN-AROUND AT BASE. - Schech's Mill, Beaver Creek State Park, La Crescent, Houston County, MN

  14. ZINC ROUGHER CELLS ON LEFT, ZINC CLEANER CELLS ON RIGHT, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ZINC ROUGHER CELLS ON LEFT, ZINC CLEANER CELLS ON RIGHT, LOOKING NORTH. NOTE ONE STYLE OF DENVER AGITATOR IN LOWER RIGHT CELL. - Shenandoah-Dives Mill, 135 County Road 2, Silverton, San Juan County, CO

  15. LEAD CLEANER CELLS, LOOKING SOUTH SOUTHWEST. NOTE SMALL HANDWHEELS FOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LEAD CLEANER CELLS, LOOKING SOUTH SOUTHWEST. NOTE SMALL HANDWHEELS FOR GATE VALVES USED TO ADJUST FLOW BETWEEN INDIVIDUAL CELLS. - Shenandoah-Dives Mill, 135 County Road 2, Silverton, San Juan County, CO

  16. Evaluation of aqueous cleaners as alternatives to vapor degreasing

    SciTech Connect

    Guidotti, R.A.; Schneider, T.W.; Frye, G.C.

    1996-05-01

    As part of the preparation process during assembly of thermally activated batteries, the stainless steel piece parts are normally cleaned by vapor degreasing with trichloroethylene. Severe restrictions on the use of chlorinated and fluorinated hydrocarbons in recent years prompted the evaluation of a number of aqueous cleaners as a replacement technology for this application. A total of seven commercial aqueous degreasers was evaluated in this study at several dilution ratios and temperatures. One organic cleaner was also examined under ambient conditions. The effectiveness of the cleaner was determined by the use of x-ray photoelectron spectroscopy (XPS), which is a surface analytical technique that is very sensitive to low levels of surface contaminants. A quartz-crystal microbalance (QCM) that is immersed in the cleaning bath was evaluated as a tool for monitoring the bath cleanliness. The best overall cleaning results were obtained with Micro, Impro-Clean 3800, and Sonicor cleaners.

  17. Detail exterior view looking northwest showing field gas cleaner in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail exterior view looking northwest showing field gas cleaner in the center. - Burnsville Natural Gas Pumping Station, Saratoga Avenue between Little Kanawha River & C&O Railroad line, Burnsville, Braxton County, WV

  18. Evaluation of aqueous cleaners as alternatives to vapor degreasing

    SciTech Connect

    Guidotti, R.A.; Schneider, T.W.; Frye, G.C.

    1996-02-01

    As part of the preparation process during assembly of thermally activated batteries, the stainless steel piece parts are normally cleaned by vapor degreasing with trichloroethylene. Severe restrictions on the use of chlorinated and fluorinated hydrocarbons in recent years prompted the evaluation of a number of aqueous cleaners as a replacement technology for this application. A total of seven commercial aqueous degreasers was evaluated in this study at several dilution ratios and temperatures. One organic cleaner was also examined under ambient conditions. The effectiveness of the cleaner was determined by the use of x-ray photoelectron spectroscopy (XPS), which is a surface analytical technique that is very sensitive to low levels of surface contaminants. A quartz-crystal microbalance (QCM) that is immersed in the cleaning bath was evaluated as a tool for monitoring the bath cleanliness. The best overall cleaning results were obtained with Micro, Impro-Clean 3800, and Sonicor cleaners.

  19. The effects of an energy efficiency retrofit on indoor air quality.

    PubMed

    Frey, S E; Destaillats, H; Cohn, S; Ahrentzen, S; Fraser, M P

    2015-04-01

    To investigate the impacts of an energy efficiency retrofit, indoor air quality and resident health were evaluated at a low-income senior housing apartment complex in Phoenix, Arizona, before and after a green energy building renovation. Indoor and outdoor air quality sampling was carried out simultaneously with a questionnaire to characterize personal habits and general health of residents. Measured indoor formaldehyde levels before the building retrofit routinely exceeded reference exposure limits, but in the long-term follow-up sampling, indoor formaldehyde decreased for the entire study population by a statistically significant margin. Indoor PM levels were dominated by fine particles and showed a statistically significant decrease in the long-term follow-up sampling within certain resident subpopulations (i.e. residents who report smoking and residents who had lived longer at the apartment complex).

  20. Replacing Chlorinated-Solvent-Based Cleaners And Adhesives

    NASA Technical Reports Server (NTRS)

    Heaton, Harley; Davidson, Fred

    1995-01-01

    Brief report describes tests conducted to assess feasibility of using selected chemicals as replacements for selected cleaners, primers, and adhesives containing chlorinated solvents. Cleaners, primers, and adhesives in question used in bonding insulating material in steel cases of solid-fuel rocket motors. Necessary to phase out use of chlorinated solvents because of concerns over toxicity and adverse effects on ozone layer in upper atmosphere.

  1. Unusual Air Filters with Ultrahigh Efficiency and Antibacterial Functionality Enabled by ZnO Nanorods.

    PubMed

    Zhong, Zhaoxiang; Xu, Zhe; Sheng, Ting; Yao, Jianfeng; Xing, Weihong; Wang, Yong

    2015-09-30

    Porous membranes/filters that can remove airborne fine particulates, for example, PM2.5, with high efficiency at low energy consumption are of significant interest. Herein, we report on the fabrication of a new class of unusual superior air filters with ultrahigh efficiency and an interesting antibacterial functionality. We use atomic layer deposition (ALD) to uniformly seed ZnO on the surface of expanded polytetrafluoroethylene (ePTFE) matrix, and then synthesize well-aligned ZnO nanorods with tunable widths and lengths from the seeds under hydrothermal conditions. The presence of ZnO nanorods reduces the effective pore sizes of the ePTFE filters at little expense of energy consumption. As a consequence, the filters exhibit exceptional dust removal efficiencies greater than 99.9999% with much lower energy consumption than conventional filters. Significantly, the presence of ZnO nanorods strongly inhibits the propagation of both Gram positive and negative bacteria on the filters. Therefore, the functionalized filters can potentially overcome the inherent limitation in the trade-off effect and imply their superiority for controlling indoor air quality.

  2. Efficient and stable perovskite solar cells prepared in ambient air irrespective of the humidity

    PubMed Central

    Tai, Qidong; You, Peng; Sang, Hongqian; Liu, Zhike; Hu, Chenglong; Chan, Helen L. W.; Yan, Feng

    2016-01-01

    Poor stability of organic–inorganic halide perovskite materials in humid condition has hindered the success of perovskite solar cells in real applications since controlled atmosphere is required for device fabrication and operation, and there is a lack of effective solutions to this problem until now. Here we report the use of lead (II) thiocyanate (Pb(SCN)2) precursor in preparing perovskite solar cells in ambient air. High-quality CH3NH3PbI3−x(SCN)x perovskite films can be readily prepared even when the relative humidity exceeds 70%. Under optimized processing conditions, we obtain devices with an average power conversion efficiency of 13.49% and the maximum efficiency over 15%. In comparison with typical CH3NH3PbI3-based devices, these solar cells without encapsulation show greatly improved stability in humid air, which is attributed to the incorporation of thiocyanate ions in the crystal lattice. The findings pave a way for realizing efficient and stable perovskite solar cells in ambient atmosphere. PMID:27033249

  3. Efficient and stable perovskite solar cells prepared in ambient air irrespective of the humidity

    NASA Astrophysics Data System (ADS)

    Tai, Qidong; You, Peng; Sang, Hongqian; Liu, Zhike; Hu, Chenglong; Chan, Helen L. W.; Yan, Feng

    2016-04-01

    Poor stability of organic-inorganic halide perovskite materials in humid condition has hindered the success of perovskite solar cells in real applications since controlled atmosphere is required for device fabrication and operation, and there is a lack of effective solutions to this problem until now. Here we report the use of lead (II) thiocyanate (Pb(SCN)2) precursor in preparing perovskite solar cells in ambient air. High-quality CH3NH3PbI3-x(SCN)x perovskite films can be readily prepared even when the relative humidity exceeds 70%. Under optimized processing conditions, we obtain devices with an average power conversion efficiency of 13.49% and the maximum efficiency over 15%. In comparison with typical CH3NH3PbI3-based devices, these solar cells without encapsulation show greatly improved stability in humid air, which is attributed to the incorporation of thiocyanate ions in the crystal lattice. The findings pave a way for realizing efficient and stable perovskite solar cells in ambient atmosphere.

  4. Air sampling filtration media: Collection efficiency for respirable size-selective sampling

    PubMed Central

    Soo, Jhy-Charm; Monaghan, Keenan; Lee, Taekhee; Kashon, Mike; Harper, Martin

    2016-01-01

    The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 μm pore sizes), polycarbonate (0.4, 0.8, 2, and 5 μm pore sizes), polytetrafluoroethylene (PTFE; 0.45, 1, 2, and 5 μm pore sizes), polyvinyl chloride (PVC; 0.8 and 5 μm pore sizes), and silver membrane (0.45, 0.8, 1.2, and 5 μm pore sizes) filters were exposed to polydisperse sodium chloride (NaCl) particles in the size range of 10–400 nm. Test aerosols were nebulized and introduced into a calm air chamber through a diffusion dryer and aerosol neutralizer. The testing filters (37 mm diameter) were mounted in a conductive polypropylene filter-holder (cassette) within a metal testing tube. The experiments were conducted at flow rates between 1.7 and 11.2 l min−1. The particle size distributions of NaCl challenge aerosol were measured upstream and downstream of the test filters by a scanning mobility particle sizer (SMPS). Three different filters of each type with at least three repetitions for each pore size were tested. In general, the collection efficiency varied with airflow, pore size, and sampling duration. In addition, both collection efficiency and pressure drop increased with decreased pore size and increased sampling flow rate, but they differed among filter types and manufacturer. The present study confirmed that the MCE, PTFE, and PVC filters have a relatively high collection efficiency for challenge particles much smaller than their nominal pore size and are considerably more efficient than polycarbonate and silver membrane filters, especially at larger nominal pore sizes. PMID:26834310

  5. Evaluation of physical sampling efficiency for cyclone-based personal bioaerosol samplers in moving air environments.

    PubMed

    Su, Wei-Chung; Tolchinsky, Alexander D; Chen, Bean T; Sigaev, Vladimir I; Cheng, Yung Sung

    2012-09-01

    The need to determine occupational exposure to bioaerosols has notably increased in the past decade, especially for microbiology-related workplaces and laboratories. Recently, two new cyclone-based personal bioaerosol samplers were developed by the National Institute for Occupational Safety and Health (NIOSH) in the USA and the Research Center for Toxicology and Hygienic Regulation of Biopreparations (RCT & HRB) in Russia to monitor bioaerosol exposure in the workplace. Here, a series of wind tunnel experiments were carried out to evaluate the physical sampling performance of these two samplers in moving air conditions, which could provide information for personal biological monitoring in a moving air environment. The experiments were conducted in a small wind tunnel facility using three wind speeds (0.5, 1.0 and 2.0 m s(-1)) and three sampling orientations (0°, 90°, and 180°) with respect to the wind direction. Monodispersed particles ranging from 0.5 to 10 μm were employed as the test aerosols. The evaluation of the physical sampling performance was focused on the aspiration efficiency and capture efficiency of the two samplers. The test results showed that the orientation-averaged aspiration efficiencies of the two samplers closely agreed with the American Conference of Governmental Industrial Hygienists (ACGIH) inhalable convention within the particle sizes used in the evaluation tests, and the effect of the wind speed on the aspiration efficiency was found negligible. The capture efficiencies of these two samplers ranged from 70% to 80%. These data offer important information on the insight into the physical sampling characteristics of the two test samplers.

  6. Aeromonas salmonicida infection levels in pre- and post-stocked cleaner fish assessed by culture and an amended qPCR assay.

    PubMed

    Gulla, S; Duodu, S; Nilsen, A; Fossen, I; Colquhoun, D J

    2016-07-01

    Due to increasing resistance to chemical therapeutants, the use of 'cleaner fish' (primarily wrasse, Labridae, species) has become popular in European salmon farming for biocontrol of the salmon louse, Lepeophtheirus salmonis (Krøyer). While being efficient de-licers, cleaner fish mortality levels in salmon cages are commonly high, and systemic bacterial infections constitute a major problem. Atypical furunculosis, caused by Aeromonas salmonicida A-layer types V and VI, is among the most common diagnoses reached in clinical investigations. A previously described real-time PCR (qPCR), targeting the A. salmonicida A-layer gene (vapA), was modified and validated for specific and sensitive detection of all presently recognized A-layer types of this bacterium. Before stocking and during episodes of increased mortality in salmon cages, cleaner fish (primarily wild-caught wrasse) were sampled and screened for A. salmonicida by qPCR and culture. Culture indicated that systemic bacterial infections are mainly contracted after salmon farm stocking, and qPCR revealed A. salmonicida prevalences of approximately 4% and 68% in pre- and post-stocked cleaner fish, respectively. This underpins A. salmonicida's relevance as a contributing factor to cleaner fish mortality and emphasizes the need for implementation of preventive measures (e.g. vaccination) if current levels of cleaner fish use are to be continued or expanded. PMID:26514414

  7. The Oklahoma Field Test: Air-Conditioning Electricity Savings from Standard Energy Conservation Measures, Radiant Barriers, and High-Efficiency Window Air Conditioners

    SciTech Connect

    Ternes, M.P.

    1992-01-01

    A field test involving 104 houses was performed in Tulsa, Oklahoma, to measure the air-conditioning electricity consumption of low-income houses equipped with window air conditioners, the reduction in this electricity consumption attributed to the installation of energy conservation measures (ECMs) as typically installed under the Oklahoma Weatherization Assistance Program (WAP), and the reduction achieved by the replacement of low-efficiency window air conditioners with high-efficiency units and the installation of attic radiant barriers. Air-conditioning electricity consumption and indoor temperature were monitored weekly during the pre-weatherization period (June to September 1988) and post-weatherization period (May to September 1989). House energy consumption models and regression analyses were used to normalize the air-conditioning electricity savings to average outdoor temperature conditions and the pre-weatherization indoor temperature of each house. The average measured pre-weatherization air-conditioning electricity consumption was 1664 kWh/year ($119/year). Ten percent of the houses used less than 250 kWh/year, while another 10% used more than 3000 kWh/year. An average reduction in air-conditioning electricity consumption of 535 kWh/year ($38/year and 28% of pre-weatherization consumption) was obtained from replacement of one low-efficiency window air conditioner (EER less than 7.0) per house with a high-efficiency unit (EER greater than 9.0). For approximately the same cost, savings tripled to 1503 kWh/year ($107/year and 41% of pre-weatherization consumption) in those houses with initial air-conditioning electricity consumption greater than 2750 kWh/year. For these houses, replacement of a low-efficiency air conditioner with a high-efficiency unit was cost effective using the incremental cost of installing a new unit now rather than later; the average installation cost for these houses under a weatherization program was estimated to be $786. The

  8. Towards energy efficient operation of Heating, Ventilation and Air Conditioning systems via advanced supervisory control design

    NASA Astrophysics Data System (ADS)

    Oswiecinska, A.; Hibbs, J.; Zajic, I.; Burnham, K. J.

    2015-11-01

    This paper presents conceptual control solution for reliable and energy efficient operation of heating, ventilation and air conditioning (HVAC) systems used in large volume building applications, e.g. warehouse facilities or exhibition centres. Advanced two-level scalable control solution, designed to extend capabilities of the existing low-level control strategies via remote internet connection, is presented. The high-level, supervisory controller is based on Model Predictive Control (MPC) architecture, which is the state-of-the-art for indoor climate control systems. The innovative approach benefits from using passive heating and cooling control strategies for reducing the HVAC system operational costs, while ensuring that required environmental conditions are met.

  9. Plutonium Finishing Plant (PFP) Waste Composition and High Efficiency Particulate Air Filter Loading

    SciTech Connect

    ZIMMERMAN, B.D.

    2000-12-11

    This analysis evaluates the effect of the Plutonium Finishing Plant (PFP) waste isotopic composition on Tank Farms Final Safety Analysis Report (FSAR) accidents involving high-efficiency particulate air (HEPA) filter failure in Double-Contained Receiver Tanks (DCRTs). The HEPA Filter Failure--Exposure to High Temperature or Pressure, and Steam Intrusion From Interfacing Systems accidents are considered. The analysis concludes that dose consequences based on the PFP waste isotopic composition are bounded by previous FSAR analyses. This supports USQD TF-00-0768.

  10. Converting sensitive waste into cleaner energy

    SciTech Connect

    Schriner, D.; Skinner, R.

    1997-10-01

    The destruction of sensitive unclassified information (SUI) has always been expensive due to the need for special controls to ensure its protection from disclosure to unauthorized persons. The sensitive documents were shredded, buried at the landfill, or sent to a recycling company. The Department of Energy (DOE) Idaho National Engineering and Environmental Laboratory (INEEL), operated by Lockheed Martin Idaho Technologies Company (LMITCO), has created an innovative method to dispose of its sensitive unclassified paper waste which has security, economic, and environmental benefits. A new cubing facility at the INEEL converts office and industrial waste into compact cubes which are then combined with coal and burned as a source of heat and process steam to run the Idaho Chemical Processing Plant (ICPP) facility. The process-engineered fuel, consisting of 25% cubes and 75% coal, bums cleaner than coal with lower emissions of sulfur dioxide and nitrogen oxides. The alternative fuel also reduces fuel costs, eliminates paying a recycling company, reduces the expense of landfill disposal, increases the life of the landfill, and provides energy to operate a large facility. The Operations Security (OPSEC) team capitalized on this waste to energy technology by recommending that the large quantities of sensitive information (documents) generated at the INEEL be disposed of in this manner. In addition to the economic and environmental benefits, this disposal method minimizes the vulnerabilities of SUI from disclosure to unauthorized personnel. The {open_quotes}cuber{close_quotes} technology has potential application in government and industry for protection of SUI.

  11. Genesis Ultrapure Water Megasonic Wafer Spin Cleaner

    NASA Technical Reports Server (NTRS)

    Allton, Judith H.; Stansbery, Eileen K.; Calaway, Michael J.; Rodriquez, Melissa C.

    2013-01-01

    A device removes, with high precision, the majority of surface particle contamination greater than 1-micron-diameter in size from ultrapure semiconductor wafer materials containing implanted solar wind samples returned by NASA's Genesis mission. This cleaning device uses a 1.5-liter/minute flowing stream of heated ultrapure water (UPW) with 1- MHz oscillating megasonic pulse energy focused at 3 to 5 mm away from the wafer surface spinning at 1,000 to 10,000 RPM, depending on sample size. The surface particle contamination is removed by three processes: flowing UPW, megasonic cavitations, and centripetal force from the spinning wafer. The device can also dry the wafer fragment after UPW/megasonic cleaning by continuing to spin the wafer in the cleaning chamber, which is purged with flowing ultrapure nitrogen gas at 65 psi (.448 kPa). The cleaner also uses three types of vacuum chucks that can accommodate all Genesis-flown array fragments in any dimensional shape between 3 and 100 mm in diameter. A sample vacuum chuck, and the manufactured UPW/megasonic nozzle holder, replace the human deficiencies by maintaining a consistent distance between the nozzle and wafer surface as well as allowing for longer cleaning time. The 3- to 5-mm critical distance is important for the ability to remove particles by megasonic cavitations. The increased UPW sonication time and exposure to heated UPW improve the removal of 1- to 5-micron-sized particles.

  12. 10 CFR 431.96 - Uniform test method for the measurement of energy efficiency of commercial air conditioners and...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... certified ratings that is required to be maintained under 10 CFR 429.71. (f) Manufacturer involvement in... efficiency of commercial air conditioners and heat pumps. 431.96 Section 431.96 Energy DEPARTMENT OF ENERGY... Air Conditioners and Heat Pumps Test Procedures § 431.96 Uniform test method for the measurement...

  13. On the efficiency and correction of vertically oriented blunt bioaerosol samplers in moving air

    NASA Astrophysics Data System (ADS)

    Michel, Dominik; Rotach, Mathias W.; Gehrig, Regula; Vogt, Roland

    2012-11-01

    The aspiration efficiency of vertical and wind-oriented Air-O-Cell samplers was investigated in a field study using the pollen of hazel, sweet chestnut and birch. Collected pollen numbers were compared to measurements of a Hirst-type Burkard spore trap. The discrepancy between pollen counts is substantial in the case of vertical orientation. The results indicate a strong influence of wind velocity and inlet orientation relative to the freestream on the aspiration efficiency. Various studies reported on inertial effects on aerosol motion as function of wind velocity. The measurements were compared to a physically based model for the limited case of vertical blunt samplers. Additionally, a simple linear model based on pollen counts and wind velocity was developed. Both correction models notably reduce the error of vertically oriented samplers, whereas only the physically based model can be used on independent datasets. The study also addressed the precision error of the instruments used, which was substantial for both sampler types.

  14. The Oklahoma Field Test: Air-conditioning electricity savings from standard energy conservation measures, radiant barriers, and high-efficiency window air conditioners

    SciTech Connect

    Ternes, M.P.; Levins, W.P.

    1992-08-01

    A field test Involving 104 houses was performed in Tulsa, Oklahoma, to measure the air-conditioning electricity consumption of low-income houses equipped with window air conditioners, the reduction in this electricity consumption attributed to the installation of energy conservation measures (ECMS) as typically installed under the Oklahoma Weatherization Assistance Program (WAP), and the reduction achieved by the replacement of low-efficiency window air conditioners with high-efficiency units and the installation of attic radiant barriers. Air-conditioning electricity consumption and indoor temperature were monitored weekly during the pre-weatherization period (June to September 1988) and post-weatherization period (May to September 1989). House energy consumption models and regression analyses were used to normalize the air-conditioning electricity savings to average outdoor temperature conditions and the pre-weatherization indoor temperature of each house. The following conclusions were drawn from the study: (1) programs directed at reducing air-conditioning electricity consumption should be targeted at clients with high consumption to improve cost effectiveness; (2) replacing low-efficiency air conditioners with high-efficiency units should be considered an option in a weatherization program directed at reducing air-conditioning electricity consumption; (3) ECMs currently being installed under the Oklahoma WAP (chosen based on effectiveness at reducing space-heating energy consumption) should continue to be justified based on their space-heating energy savings potential only; and (4) attic radiant barriers should not be included in the Oklahoma WAP if alternatives with verified savings are available or until further testing demonstrates energy savings or other benefits in this typo of housing.

  15. Integrating affordability, energy and environmental efficiency, air quality and disaster resistance into residential design and construction

    SciTech Connect

    Cook, G.D.

    1995-12-31

    Much has been researched and written about the individual qualities of good home design and construction in terms of: energy efficiency; affordability; indoor air quality; sustainability; and wind, fire, and flood resistance. The real challenge is to integrate all these characteristics into the ideal house. The purpose of this paper is to review the characteristics of each of the above features and explore the integration of them into the ideal residential structure. The house would take the shape of a compact two story structure. A geometrically compact structure uses less construction materials per floor area, presents less area for improved thermal efficiency, and less profile for wind and flood resistance. The first floor would be constructed using insulated strong high thermal mass masonry system resistant to flood, wind, fire, and termite damage. The second story would be constructed using a lighter reinforced wood frame system with between stud insulation coupled with exterior insulated sheathing to minimize thermal bridging across studs. Optimizing floor plan such as separating living and sleeping areas present opportunities for efficient split HVAC zoning, natural ventilation, and solar passive adaptation. The design would emphasize the 4, 8, and 12 foot dimensioning for waste reduction; selection of environmentally friendly building materials, such as cellulose insulation; and efficient lighting and appliances. Features providing improved indoor air quality such as prudent duct selection, design and location, use of radon barriers, omission of carpeting, and control of moisture would be addressed. The design philosophy, concepts and rationale for the integration of these and many other features of the ideal residence will be addressed and illustrated.

  16. High-Performing Polycarbazole Derivatives for Efficient Solution-Processing of Organic Solar Cells in Air.

    PubMed

    Burgués-Ceballos, Ignasi; Hermerschmidt, Felix; Akkuratov, Alexander V; Susarova, Diana K; Troshin, Pavel A; Choulis, Stelios A

    2015-12-21

    The application of conjugated materials in organic photovoltaics (OPVs) is usually demonstrated in lab-scale spin-coated devices that are processed under controlled inert conditions. Although this is a necessary step to prove high efficiency, testing of promising materials in air should be done in the early stages of research to validate their real potential for low-cost, solution-processed, and large-scale OPVs. Also relevant for approaching commercialization needs is the use of printing techniques that are compatible with upscaling. Here, solution processing of organic solar cells based on three new poly(2,7-carbazole) derivatives is efficiently transferred, without significant losses, to air conditions and to several deposition methods using a simple device architecture. High efficiencies in the range between 5.0 % and 6.3 % are obtained in (rigid) spin-coated, doctor-bladed, and (flexible) slot-die-coated devices, which surpass the reference devices based on poly[N-9'-heptadecanyl-2,7-carbazole-alt-5,5-(4',7'-di-2-thienyl-2',1',3'-benzothiadiazole)] (PCDTBT). In contrast, inkjet printing does not provide reliable results with the presented polymers, which is attributed to their high molecular weight. When the device area in the best-performing system is increased from 9 mm(2) to 0.7 cm(2), the efficiency drops from 6.2 % to 5.0 %. Photocurrent mapping reveals inhomogeneous current generation derived from changes in the thickness of the active layer. PMID:26663820

  17. Dummies versus air puffs: efficient stimulus delivery for low-volatile odors.

    PubMed

    Brandstaetter, Andreas Simon; Rössler, Wolfgang; Kleineidam, Christoph Johannes

    2010-05-01

    Aiming to unravel how animals perceive odors, a variety of neurophysiological techniques are used today. For olfactory stimulation, odors are commonly incorporated into a constant airstream that carries odor molecules to the receptor organ (air-delivered stimulation). Such odor delivery works well for odors of high volatility (naturally effective over long distances) but less or not at all for low-volatile odors (usually only received at short range). We developed a new odor stimulation technique especially suited for low-volatile odors and compared it with conventional air-delivered stimulation using 2 neurophysiological approaches. Odor-loaded dummies were moved into close vicinity of the receptor organs on the antenna of the Florida carpenter ant Camponotus floridanus (dummy-delivered stimulation). Neuronal activity was monitored either at receptor neuron level using electroantennography or in the first olfactory neuropile, the antennal lobes, using calcium imaging. We tested 3 odors of different volatility: C. floridanus' highly volatile alarm pheromone undecane, its low-volatile trail pheromone nerolic acid, and an even less volatile, behaviorally active C23 alkene, cis-9-tricosene. For low-volatile odors, dummy-delivered stimulation was particularly efficient. We conclude that dummy-delivered stimulation is advantageous compared to the commonly used air-delivered stimulation when studying an animal's detection and processing of low-volatile odors.

  18. Dummies versus air puffs: efficient stimulus delivery for low-volatile odors.

    PubMed

    Brandstaetter, Andreas Simon; Rössler, Wolfgang; Kleineidam, Christoph Johannes

    2010-05-01

    Aiming to unravel how animals perceive odors, a variety of neurophysiological techniques are used today. For olfactory stimulation, odors are commonly incorporated into a constant airstream that carries odor molecules to the receptor organ (air-delivered stimulation). Such odor delivery works well for odors of high volatility (naturally effective over long distances) but less or not at all for low-volatile odors (usually only received at short range). We developed a new odor stimulation technique especially suited for low-volatile odors and compared it with conventional air-delivered stimulation using 2 neurophysiological approaches. Odor-loaded dummies were moved into close vicinity of the receptor organs on the antenna of the Florida carpenter ant Camponotus floridanus (dummy-delivered stimulation). Neuronal activity was monitored either at receptor neuron level using electroantennography or in the first olfactory neuropile, the antennal lobes, using calcium imaging. We tested 3 odors of different volatility: C. floridanus' highly volatile alarm pheromone undecane, its low-volatile trail pheromone nerolic acid, and an even less volatile, behaviorally active C23 alkene, cis-9-tricosene. For low-volatile odors, dummy-delivered stimulation was particularly efficient. We conclude that dummy-delivered stimulation is advantageous compared to the commonly used air-delivered stimulation when studying an animal's detection and processing of low-volatile odors. PMID:20212009

  19. Assessment of Nanoparticle Exposure in Nanosilica Handling Process: Including Characteristics of Nanoparticles Leaking from a Vacuum Cleaner

    PubMed Central

    KIM, Boowook; KIM, Hyunwook; YU, Il Je

    2013-01-01

    Nanosilica is one of the most widely used nanomaterials across the world. However, their assessment data on the occupational exposure to nanoparticles is insufficient. The present study performed an exposure monitoring in workplace environments where synthetic powders are prepared using fumed nanosilica. Furthermore, after it was observed during exposure monitoring that nanoparticles were emitted through leakage in a vacuum cleaner (even with a HEPA-filter installed in it), the properties of the leaked nanoparticles were also investigated. Workers were exposed to high-concentration nanosilica emitted into the air while pouring it into a container or transferring the container. The use of a vacuum cleaner with a leak (caused by an inadequate sealing) was found to be the origin of nanosilica dispersion in the indoor air. While the particle size of the nanosilica that emitted into the air (during the handling of nanosilica by a worker) was mostly over 100 nm or several microns (µm) due to the coagulation of particles, the size of nanosilica that leaked out of vacuum cleaner was almost similar to the primary size (mode diameter 11.5 nm). Analysis of area samples resulted in 20% (60% in terms of peak concentration) less than the analysis of the personals sample. PMID:24366536

  20. Assessment of nanoparticle exposure in nanosilica handling process: including characteristics of nanoparticles leaking from a vacuum cleaner.

    PubMed

    Kim, Boowook; Kim, Hyunwook; Yu, Il Je

    2014-01-01

    Nanosilica is one of the most widely used nanomaterials across the world. However, their assessment data on the occupational exposure to nanoparticles is insufficient. The present study performed an exposure monitoring in workplace environments where synthetic powders are prepared using fumed nanosilica. Furthermore, after it was observed during exposure monitoring that nanoparticles were emitted through leakage in a vacuum cleaner (even with a HEPA-filter installed in it), the properties of the leaked nanoparticles were also investigated. Workers were exposed to high-concentration nanosilica emitted into the air while pouring it into a container or transferring the container. The use of a vacuum cleaner with a leak (caused by an inadequate sealing) was found to be the origin of nanosilica dispersion in the indoor air. While the particle size of the nanosilica that emitted into the air (during the handling of nanosilica by a worker) was mostly over 100 nm or several microns (µm) due to the coagulation of particles, the size of nanosilica that leaked out of vacuum cleaner was almost similar to the primary size (mode diameter 11.5 nm). Analysis of area samples resulted in 20% (60% in terms of peak concentration) less than the analysis of the personals sample. PMID:24366536

  1. Assessment of nanoparticle exposure in nanosilica handling process: including characteristics of nanoparticles leaking from a vacuum cleaner.

    PubMed

    Kim, Boowook; Kim, Hyunwook; Yu, Il Je

    2014-01-01

    Nanosilica is one of the most widely used nanomaterials across the world. However, their assessment data on the occupational exposure to nanoparticles is insufficient. The present study performed an exposure monitoring in workplace environments where synthetic powders are prepared using fumed nanosilica. Furthermore, after it was observed during exposure monitoring that nanoparticles were emitted through leakage in a vacuum cleaner (even with a HEPA-filter installed in it), the properties of the leaked nanoparticles were also investigated. Workers were exposed to high-concentration nanosilica emitted into the air while pouring it into a container or transferring the container. The use of a vacuum cleaner with a leak (caused by an inadequate sealing) was found to be the origin of nanosilica dispersion in the indoor air. While the particle size of the nanosilica that emitted into the air (during the handling of nanosilica by a worker) was mostly over 100 nm or several microns (µm) due to the coagulation of particles, the size of nanosilica that leaked out of vacuum cleaner was almost similar to the primary size (mode diameter 11.5 nm). Analysis of area samples resulted in 20% (60% in terms of peak concentration) less than the analysis of the personals sample.

  2. Comparison of filter bag, cyclonic, and wet dust collection methods in vacuum cleaners.

    PubMed

    Trakumas, S; Willeke, K; Reponen, T; Grinshpun, S A; Friedman, W

    2001-01-01

    In this study, methods were developed for comparative evaluation of three primary dust collection methods employed in vacuum cleaners: filter bag, cyclonic, and wet primary dust collection. The dry collectors were evaluated with KCl test aerosols that are commonly used in filter testing. However, these aerosols cannot be used for evaluating wet collectors due to their hygroscopicity. Therefore, the wet collectors were evaluated with nonhygroscopic test particles. Both types of test aerosol indicated similar collection efficiencies in tests with dry collectors. The data show that high initial collection efficiency can be achieved by any one of the three dust collection methods: up to 50% for 0.35 microm particles, and close to 100% for 1.0 microm and larger particles. The degree of dependence of the initial collection efficiency on airflow rate was strongly related to the type and manufacturing of the primary dust collector. Collection efficiency decreased most with decreasing flow rate for the tested wet collectors. The tested cyclonic and wet collectors showed high reentrainment of already collected dust particles. After the filter bag collectors had been loaded with test dust, they also reemitted particles. The degree of reentrainment from filter bags depends on the particulate load and the type of filter material used. Thus, the overall particle emissions performance of a vacuum cleaner depends not only on the dust collection efficiency of the primary collector and other filtration elements employed, but also on the degree of reentrainment of already collected particles.

  3. The survival and recovery of bacteria in vacuum cleaner dust.

    PubMed

    Haysom, I W; Sharp, K

    2003-03-01

    The possibility exists that environmental dust could be a source of gastro-intestinal infection in the domestic environment and that the causative microbes are collected during vacuum cleaning. This study examines the survival of total bacterial populations, Enterobacteriaceae and salmonella species in vacuum cleaner dust in vitro and in use. Total counts remain constant at around 10(6)-10(8) colony forming units (cfu) g-1 for at least 60 days. Enterobacteriaceae showed only a slight decline over the same period. Recovery of salmonellae artificially inoculated into vacuum dust was dose and time dependent: even relatively small inocula (< 100 cfu g-1) were recoverable more than one month after inoculation. Questionnaires and vacuum cleaner dust samples were received from 76 households. A significant association was found between total bacterial counts and whether the household was in a rural or urban situation and the number of people in the household. No association was found between total bacterial counts and the number of children in the household, the presence of pets, wearing shoes indoors, the makes, model and age of the vacuum cleaner, the type of dust collector or dust bag, how often the vacuum cleaner was used and the length of time between sample collection and microbiological testing. Salmonella species were isolated from vacuum cleaner dust from three of the 76 households although no factors could be identified linking the homes. This study shows that vacuum cleaners are effective collectors and reservoirs of microbial contamination and that these contaminants are able to survive for up to two months. Vacuum cleaner dust could thus be a useful indicator of environmental contamination in the home.

  4. Pneumatic colon injury following high pressure blow gun dust cleaner spray to the perineum

    PubMed Central

    Sy, Edgar D.; Chiu, Yin-I.; Shan, Yan-Shen; Ong, Roger L.

    2014-01-01

    Introduction A pneumatic tool or air tool such as blow gun dust cleaner is a tool driven by compressed air and spraying of the perineum can insufflate the colon due to its high pressure and high flow rate. Presentation of case We present a case of 4 year old boy who developed sudden onset of tense abdominal distention and developed peritonitis. Patient’s family initially denied a history of trauma. Radiologic examination showed pneumoperitoneum and colon dilatation. Exploratory laparotomy revealed a tension pneumoperitoneum, bloody ascitic fluid, multiple site of ecchymosis and serosal tear of the colon and a minute perforation of transverse colon. Postoperative reinvestigation revealed that the patient’s perineum was sprayed, using blow gun dust cleaner. Discussion Air from pneumatic tools produces column of air at pressure of 3.5–8.8 kg/cm2 and pressure greater than the resting anal pressure of 0.109 kg/cm2 force air to enter the colon when the perineum is sprayed. Different degree of colon injury results when airflow is greater than 1.46 L/m, and/or intraluminal pressure greater than 0.109 kg/cm2. In most children, initial anxiety to tell the truth result in difficulty to obtain good history. Conclusion Spraying of the perianal with excessive pneumatic force of greater than the resting anal pressure and high air flow rate causes multiple site colon injury and tension pneumoperitoneum due to colon perforation. Parent should be caution in children playing with high pressure pneumatic tool, and the importance of history is emphases for early correct diagnosis. PMID:25544492

  5. Cleaner production: Minimizing hazardous waste in Indonesia

    SciTech Connect

    Bratasida, D.L.

    1996-12-31

    In the second long-term development plan, industry plays a significant role in economic growth. In Indonesia, industries grow very fast; such fast growth can adversely effect the environment. Exploitation of assets can mean depletion of natural resources and energy, which, if incorrectly managed, can endanger human life and the environment. The inefficient use of natural resources will accelerate their exhaustion and generate pollution, resulting in environmental damage and threats to economic development and human well being. In recent years, changes in the approach used to control pollution have been necessary because of the increasing seriousness of the problems. Initial environmental management strategies were based on a carrying capacity approach; the natural assimilative capacity accommodated the pollution load that was applied. The environmental management strategies adopted later included technologies applied to the end of the discharge point (so-called {open_quotes}end-of-pipe{close_quotes} treatments). Until now, environmental management strategies focused on end-of-pipe approaches that control pollutants after they are generated. These approaches concentrate on waste treatment and disposal to control pollution and environmental degradation. However, as industry develops, waste volumes continue to increase, thereby creating further environmental problems. In addition, the wastes produced tend to have more complex characteristics and are potentially more difficult to treat for a reasonable cost. There are often technical and financial obstacles to regulatory compliance if waste treatment is relied on as the only means of achieving environmental objectives. Consequently, the reactive end-of-pipe treatment approach has been changed to a proactive cleaner production approach. This approach is based on the concept of sustainable development and is designed to prevent pollution as well as to protect natural resources and the quality of the environment.

  6. 76 FR 30545 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-26

    ...Pursuant to section 112(l) of the Clean Air Act (``CAA'') and Federal regulations promulgated thereunder, the Maine Department of Environmental Protection (``ME DEP'') submitted a request for approval to implement and enforce the amended ``Chapter 125: Perchloroethylene Dry Cleaner Regulation'' (Maine Dry Cleaner Rule) as a partial substitution for the amended National Emissions Standards for......

  7. GUIDE TO CALCULATING TRANSPORT EFFICIENCY OF AEROSOLS IN OCCUPATIONAL AIR SAMPLING SYSTEMS

    SciTech Connect

    Hogue, M.; Hadlock, D.; Thompson, M.; Farfan, E.

    2013-11-12

    This report will present hand calculations for transport efficiency based on aspiration efficiency and particle deposition losses. Because the hand calculations become long and tedious, especially for lognormal distributions of aerosols, an R script (R 2011) will be provided for each element examined. Calculations are provided for the most common elements in a remote air sampling system, including a thin-walled probe in ambient air, straight tubing, bends and a sample housing. One popular alternative approach would be to put such calculations in a spreadsheet, a thorough version of which is shared by Paul Baron via the Aerocalc spreadsheet (Baron 2012). To provide greater transparency and to avoid common spreadsheet vulnerabilities to errors (Burns 2012), this report uses R. The particle size is based on the concept of activity median aerodynamic diameter (AMAD). The AMAD is a particle size in an aerosol where fifty percent of the activity in the aerosol is associated with particles of aerodynamic diameter greater than the AMAD. This concept allows for the simplification of transport efficiency calculations where all particles are treated as spheres with the density of water (1g cm-3). In reality, particle densities depend on the actual material involved. Particle geometries can be very complicated. Dynamic shape factors are provided by Hinds (Hinds 1999). Some example factors are: 1.00 for a sphere, 1.08 for a cube, 1.68 for a long cylinder (10 times as long as it is wide), 1.05 to 1.11 for bituminous coal, 1.57 for sand and 1.88 for talc. Revision 1 is made to correct an error in the original version of this report. The particle distributions are based on activity weighting of particles rather than based on the number of particles of each size. Therefore, the mass correction made in the original version is removed from the text and the calculations. Results affected by the change are updated.

  8. High Efficiency Liquid-Desiccant Regenerator for Air Conditioning and Industrial Drying

    SciTech Connect

    Andrew Lowenstein

    2005-12-19

    Over 2 quads of fossil fuels are used each year for moisture removal. This includes industrial and agricultural processes where feedstocks and final products must be dried, as well as comfort conditioning of indoor spaces where the control of humidity is essential to maintaining healthy, productive and comfortable working conditions. Desiccants, materials that have a high affinity for water vapor, can greatly reduce energy use for both drying and dehumidification. An opportunity exists to greatly improve the competitiveness of advanced liquid-desiccant systems by increasing the efficiency of their regenerators. It is common practice within the chemical process industry to use multiple stage boilers to improve the efficiency of thermal separation processes. The energy needed to regenerate a liquid desiccant, which is a thermal separation process, can also be reduced by using a multiple stage boiler. In this project, a two-stage regenerator was developed in which the first stage is a boiler and the second stage is a scavenging-air regenerator. The only energy input to this regenerator is the natural gas that fires the boiler. The steam produced in the boiler provides the thermal energy to run the second-stage scavenging-air regenerator. This two-stage regenerator is referred to as a 1?-effect regenerator. A model of the high-temperature stage of a 1?-effect regenerator for liquid desiccants was designed, built and successfully tested. At nominal operating conditions (i.e., 2.35 gpm of 36% lithium chloride solution, 307,000 Btu/h firing rate), the boiler removed 153 lb/h of water from the desiccant at a gas-based efficiency of 52.9 % (which corresponds to a COP of 0.95 when a scavenging-air regenerator is added). The steam leaving the boiler, when condensed, had a solids concentration of less than 10 ppm. This low level of solids in the condensate places an upper bound of about 6 lb per year for desiccant loss from the regenerator. This low loss will not create

  9. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    SciTech Connect

    Zhou, Nan; Fridley, David; Zheng, Nina; Pierrot, Andre

    2010-06-07

    of all countries energy strategies. As we all know, a very large amount of total energy consumption is due to energy consuming products and equipment, which account for about 50% of China's total energy consumption. However, the current average energy utilization efficiency of this sector is only about 60%, 10 percent lower than the international advanced level. Therefore, China's energy consuming products and equipment sector holds great energy-saving potential. On the other hand, the energy supplied to these products is mainly from fossil fuel combustion, a major source of greenhouse gas (GHG) emissions. Therefore, improving the energy efficiency and augmenting the market share of market-dominant energy consuming products is of significant importance to achieving China's energy saving and emission reduction target and is an effective means to deal with energy and environmental constraints and climate change issues. Main energy consuming products generally include widely-used home appliances, industrial equipment, office equipment, transportation vehicles, etc. China is one of the major manufacturers and exporters of energy end-using products such as air-conditioners, refrigerators, televisions, etc. Their overall energy efficiency is comparatively low and the products are poorly designed, leading to great energy-saving potential. For example, electricity consumption of air conditioners accounts for about 20% of China's total electricity consumption and 40% of the summer electricity peak load in large and medium cities. However, less than 5% of units sold in the domestic market in 2009 reached the standard's highly efficient level of grade 2 above. The electricity consumption of electric motors and their related drive systems accounts for about 60% of China's total electricity consumption; however, less than 2% of the domestic market share consists of energy-efficient electric motor products. Promoting the energy efficiency and market shares of main energy

  10. 10 CFR 431.76 - Uniform test method for the measurement of energy efficiency of commercial warm air furnaces.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy efficiency of commercial warm air furnaces. 431.76 Section 431.76 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Warm...

  11. 10 CFR 431.76 - Uniform test method for the measurement of energy efficiency of commercial warm air furnaces.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform test method for the measurement of energy efficiency of commercial warm air furnaces. 431.76 Section 431.76 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Warm...

  12. 10 CFR 431.76 - Uniform test method for the measurement of energy efficiency of commercial warm air furnaces.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform test method for the measurement of energy efficiency of commercial warm air furnaces. 431.76 Section 431.76 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Warm...

  13. Hidden Savings from a Cleaner America

    ERIC Educational Resources Information Center

    Kimball, Thomas L.

    1972-01-01

    Need for air and water cleanup campaigns are advocated, allowing taxpayers/consumers financial savings on pollution damages. Estimates show $113./year/family saved on air cleanup by 1976 and $87./year/family saved on water cleanup by 1980. (BL)

  14. Microbial Contents of Vacuum Cleaner Bag Dust and Emitted Bioaerosols and Their Implications for Human Exposure Indoors

    PubMed Central

    Veillette, Marc; Knibbs, Luke D.; Pelletier, Ariane; Charlebois, Remi; Blais Lecours, Pascale; He, Congrong; Morawska, Lidia

    2013-01-01

    Vacuum cleaners can release large concentrations of particles, both in their exhaust air and from resuspension of settled dust. However, the size, variability, and microbial diversity of these emissions are unknown, despite evidence to suggest they may contribute to allergic responses and infection transmission indoors. This study aimed to evaluate bioaerosol emission from various vacuum cleaners. We sampled the air in an experimental flow tunnel where vacuum cleaners were run, and their airborne emissions were sampled with closed-face cassettes. Dust samples were also collected from the dust bag. Total bacteria, total archaea, Penicillium/Aspergillus, and total Clostridium cluster 1 were quantified with specific quantitative PCR protocols, and emission rates were calculated. Clostridium botulinum and antibiotic resistance genes were detected in each sample using endpoint PCR. Bacterial diversity was also analyzed using denaturing gradient gel electrophoresis (DGGE), image analysis, and band sequencing. We demonstrated that emission of bacteria and molds (Penicillium/Aspergillus) can reach values as high as 1E5 cell equivalents/min and that those emissions are not related to each other. The bag dust bacterial and mold content was also consistent across the vacuums we assessed, reaching up to 1E7 bacterial or mold cell equivalents/g. Antibiotic resistance genes were detected in several samples. No archaea or C. botulinum was detected in any air samples. Diversity analyses showed that most bacteria are from human sources, in keeping with other recent results. These results highlight the potential capability of vacuum cleaners to disseminate appreciable quantities of molds and human-associated bacteria indoors and their role as a source of exposure to bioaerosols. PMID:23934489

  15. Microbial contents of vacuum cleaner bag dust and emitted bioaerosols and their implications for human exposure indoors.

    PubMed

    Veillette, Marc; Knibbs, Luke D; Pelletier, Ariane; Charlebois, Remi; Blais Lecours, Pascale; He, Congrong; Morawska, Lidia; Duchaine, Caroline

    2013-10-01

    Vacuum cleaners can release large concentrations of particles, both in their exhaust air and from resuspension of settled dust. However, the size, variability, and microbial diversity of these emissions are unknown, despite evidence to suggest they may contribute to allergic responses and infection transmission indoors. This study aimed to evaluate bioaerosol emission from various vacuum cleaners. We sampled the air in an experimental flow tunnel where vacuum cleaners were run, and their airborne emissions were sampled with closed-face cassettes. Dust samples were also collected from the dust bag. Total bacteria, total archaea, Penicillium/Aspergillus, and total Clostridium cluster 1 were quantified with specific quantitative PCR protocols, and emission rates were calculated. Clostridium botulinum and antibiotic resistance genes were detected in each sample using endpoint PCR. Bacterial diversity was also analyzed using denaturing gradient gel electrophoresis (DGGE), image analysis, and band sequencing. We demonstrated that emission of bacteria and molds (Penicillium/Aspergillus) can reach values as high as 1E5 cell equivalents/min and that those emissions are not related to each other. The bag dust bacterial and mold content was also consistent across the vacuums we assessed, reaching up to 1E7 bacterial or mold cell equivalents/g. Antibiotic resistance genes were detected in several samples. No archaea or C. botulinum was detected in any air samples. Diversity analyses showed that most bacteria are from human sources, in keeping with other recent results. These results highlight the potential capability of vacuum cleaners to disseminate appreciable quantities of molds and human-associated bacteria indoors and their role as a source of exposure to bioaerosols.

  16. Interactions between energy efficiency and emission trading under the 1990 Clean Air Act Amendments

    SciTech Connect

    Hillsman, E.L.; Alvic, D.R.

    1994-08-01

    The 1990 Clean Air Act Amendments affect electric utilities in numerous ways. The feature that probably has received the greatest attention is the provision to let utilities trade emissions of sulfur dioxide (SO{sub 2}), while at the same time requiring them to reduce S0{sub 2} emissions in 2000 by an aggregate 43%. The emission trading system was welcomed by many as a way of reducing the cost of reducing emissions, by providing greater flexibility than past approaches. This report examines some of the potential interactions between trading emissions and increasing end-use energy efficiency. The analysis focuses on emission trading in the second phase of the trading program, which begins in 2000. The aggregate effects, calculated by an emission compliance and trading model, turn out to be rather small. Aggressive improvement of end-use efficiency by all utilities might reduce allowance prices by $22/ton (1990 dollars), which is small compared to the reduction that has occurred in the estimates of future allowance prices and when compared to the roughly $400/ton price we estimate as a base case. However, the changes in the allowance market that result are large enough to affect some compliance decisions. If utilities in only a few states improve end-use efficiency aggressively, their actions may not have a large effect on the price of an allowance, but they could alter the demand for allowances and thereby the compliance decisions of utilities in other states. The analysis shows how improving electricity end-use efficiency in some states can cause smaller emission reductions in other states, relative to what would have happened without the improvements. Such a result, while not surprising given the theory behind the emission trading system, is upsetting to people who view emissions, environmental protection, and energy efficiency in moral rather than strictly economic terms.

  17. Efficient polymer light-emitting diode with air-stable aluminum cathode

    NASA Astrophysics Data System (ADS)

    Abbaszadeh, D.; Wetzelaer, G. A. H.; Doumon, N. Y.; Blom, P. W. M.

    2016-03-01

    The fast degradation of polymer light-emitting diodes (PLEDs) in ambient conditions is primarily due to the oxidation of highly reactive metals, such as barium or calcium, which are used as cathode materials. Here, we report the fabrication of PLEDs using an air-stable partially oxidized aluminum (AlOx) cathode. Usually, the high work function of aluminum (4.2 eV) imposes a high barrier for injecting electrons into the lowest unoccupied molecular orbital (LUMO) of the emissive polymer (2.9 eV below the vacuum level). By partially oxidizing aluminum, its work function is decreased, but not sufficiently low for efficient electron injection. Efficient injection is obtained by inserting an electron transport layer of poly[(9,9-di-n-octylfluorenyl-2,7-diyl)-alt-(benzo[2,1,3]thiadiazol-4,8-diyl)] (F8BT), which has its LUMO at 3.3 eV below vacuum, between the AlOx cathode and the emissive polymer. The intermediate F8BT layer not only serves as a hole-blocking layer but also provides an energetic staircase for electron injection from AlOx into the emissive layer. PLEDs with an AlOx cathode and F8BT interlayer exhibit a doubling of the efficiency as compared to conventional Ba/Al PLEDs, and still operate even after being kept in ambient atmosphere for one month without encapsulation.

  18. Heterogeneous photocatalysis for air and water treatment: Fundamental needs for quantum efficiency enhancement

    SciTech Connect

    Ollis, D.F.

    1996-09-01

    In the remediation industries, a useful treatment technology must be {open_quotes}general, robust, and cheap{close_quotes}. Among oxidation processes, heterogeneous photocatalysis is now broadly demonstrated to destroy common water and air contaminants. The potential process uses of highly stable titania, long lived lamps (one year), and room temperature operation, indicating a simple and robust process. We are left to address the third criterion: Can photocatalysis be {open_quotes}cheap{close_quotes}? In both liquid phase and gas phase treatment and purification by photocatalysis, it is established that the primary barrier to commercialization is often cost. Cost in return is dominated by the efficiency with which solar or lamp photons are harvested for productive light, and subsequent dark, reactions. This paper therefore defines fundamental needs in photocatalysis for pollution control in terms of activities which could lead to quantum efficiency enhancement. We first recall three related definitions. The quantum yield (QY) is the ratio of molecules of reactant converted per photon absorbed, a fundamental quantity. A less fundamental, but more easily measured variable is the quantum efficiency (QE), the ratio of molecules converted per photon entering the reactor. A third variable is the energy required per order of magnitude pollutant reduction, or EEO, a definition which provides for easy energy cost comparisons among different technologies. Each measure cited here reflects the photon, and thus the electrical, cost of this photochemistry.

  19. Bio-inspired, efficient, artificial lung employing air as the ventilating gas.

    PubMed

    Potkay, Joseph A; Magnetta, Michael; Vinson, Abigail; Cmolik, Brian

    2011-09-01

    Artificial lungs have recently been utilized to rehabilitate patients suffering from lung diseases. However, significant advances in gas exchange, biocompatibility, and portability are required to realize their full clinical potential. Here, we have focused on the issues of gas exchange and portability and report a small-scale, microfabricated artificial lung that uses new mathematical modeling and a bio-inspired design to achieve oxygen exchange efficiencies much larger than current devices, thereby enabling air to be utilized as the ventilating gas. This advancement eliminates the need for pure oxygen required by conventional artificial lung systems and is achieved through a device with feature sizes and structure similar to that in the natural lung. This advancement represents a significant step towards creating the first truly portable and implantable artificial lung systems for the ambulatory care of patients suffering from lung diseases.

  20. Efficient remediation of pentachlorophenol contaminated soil with tetrapolyphosphate washing and subsequent ZVI/Air treatment.

    PubMed

    Cao, Menghua; Wang, Li; Ai, Zhihui; Zhang, Lizhi

    2015-07-15

    In this study, we demonstrate that pentachlorophenol contaminated soil can be efficiently remediated with tetrapolyphosphate washing and subsequent zerovalent iron (ZVI)/Air treatment. 2 mmol L(-1) of tetrapolyphosphate could wash away 52.8% of pentachlorophenol (PCP) at pH 7.0 and 84.2% of pentachlorophenol at pH 11.0 from contaminated soil owing to the promotion effect of tetrapolyphosphate on the soil matrix dispersion and the subsequent solubilization of pentachlorophenol. More importantly, tetrapolyphosphate ions remained in the washing effluent could greatly enhance the molecular oxygen activation by ZVI to oxidize the desorbed PCP without any pH adjustment, and also avoid the competitive consumption of reactive oxygen species, as caused by the common organic surfactants in the washing effluent. Therefore, 85.1% of pentachlorophenol could be aerobically removed from the washing effluent by merely using 5 g L(-1) of ZVI. We also interestingly found that the dissolved iron ions released from the soil could enhance the oxidation of pentachlorophenol in the washing effluent, but the dissolved organic matter had the opposite effect. This study suggests the coupling tetrapolyphosphate washing and subsequent ZVI/Air treatment is an optional approach to remediate pentachlorophenol contaminated soil in view of its low cost and environmental benign.

  1. Analysis of two 'home remedy' contact lens cleaners.

    PubMed

    Diefenbach, C B; Seibert, C K; Davis, L J

    1988-07-01

    In this study, we compared the cleaning efficacy of two "home remedy" contact lens cleaners, baking soda and popcorn salt, to the FDA approved "soft" abrasive cleaner, Opticlean. Ten deposited soft contact lenses were cut into four equal sections. The first section was left uncleaned and served as a control. The other three sections were cleaned with Opticlean, a baking soda-distilled water paste, and a mixture of Pliagel and popcorn salt, respectively. A quantitative analysis indicated that the area of the lens surface covered by deposits was not significantly different for the three experimental sections, but all three were significantly cleaner than the control. In addition, there were numerous deep scratches on the lens surfaces cleaned with baking soda and popcorn salt.

  2. High-efficiency particulate air filter test stand and aerosol generator for particle loading studies.

    PubMed

    Arunkumar, R; Hogancamp, Kristina U; Parsons, Michael S; Rogers, Donna M; Norton, Olin P; Nagel, Brian A; Alderman, Steven L; Waggoner, Charles A

    2007-08-01

    This manuscript describes the design, characterization, and operational range of a test stand and high-output aerosol generator developed to evaluate the performance of 30 x 30 x 29 cm(3) nuclear grade high-efficiency particulate air (HEPA) filters under variable, highly controlled conditions. The test stand system is operable at volumetric flow rates ranging from 1.5 to 12 standard m(3)/min. Relative humidity levels are controllable from 5%-90% and the temperature of the aerosol stream is variable from ambient to 150 degrees C. Test aerosols are produced through spray drying source material solutions that are introduced into a heated stainless steel evaporation chamber through an air-atomizing nozzle. Regulation of the particle size distribution of the aerosol challenge is achieved by varying source solution concentrations and through the use of a postgeneration cyclone. The aerosol generation system is unique in that it facilitates the testing of standard HEPA filters at and beyond rated media velocities by consistently providing, into a nominal flow of 7 standard m(3)/min, high mass concentrations (approximately 25 mg/m(3)) of dry aerosol streams having count mean diameters centered near the most penetrating particle size for HEPA filters (120-160 nm). Aerosol streams that have been generated and characterized include those derived from various concentrations of KCl, NaCl, and sucrose solutions. Additionally, a water insoluble aerosol stream in which the solid component is predominantly iron (III) has been produced. Multiple ports are available on the test stand for making simultaneous aerosol measurements upstream and downstream of the test filter. Types of filter performance related studies that can be performed using this test stand system include filter lifetime studies, filtering efficiency testing, media velocity testing, evaluations under high mass loading and high humidity conditions, and determination of the downstream particle size distributions.

  3. High-efficiency particulate air filter test stand and aerosol generator for particle loading studies.

    PubMed

    Arunkumar, R; Hogancamp, Kristina U; Parsons, Michael S; Rogers, Donna M; Norton, Olin P; Nagel, Brian A; Alderman, Steven L; Waggoner, Charles A

    2007-08-01

    This manuscript describes the design, characterization, and operational range of a test stand and high-output aerosol generator developed to evaluate the performance of 30 x 30 x 29 cm(3) nuclear grade high-efficiency particulate air (HEPA) filters under variable, highly controlled conditions. The test stand system is operable at volumetric flow rates ranging from 1.5 to 12 standard m(3)/min. Relative humidity levels are controllable from 5%-90% and the temperature of the aerosol stream is variable from ambient to 150 degrees C. Test aerosols are produced through spray drying source material solutions that are introduced into a heated stainless steel evaporation chamber through an air-atomizing nozzle. Regulation of the particle size distribution of the aerosol challenge is achieved by varying source solution concentrations and through the use of a postgeneration cyclone. The aerosol generation system is unique in that it facilitates the testing of standard HEPA filters at and beyond rated media velocities by consistently providing, into a nominal flow of 7 standard m(3)/min, high mass concentrations (approximately 25 mg/m(3)) of dry aerosol streams having count mean diameters centered near the most penetrating particle size for HEPA filters (120-160 nm). Aerosol streams that have been generated and characterized include those derived from various concentrations of KCl, NaCl, and sucrose solutions. Additionally, a water insoluble aerosol stream in which the solid component is predominantly iron (III) has been produced. Multiple ports are available on the test stand for making simultaneous aerosol measurements upstream and downstream of the test filter. Types of filter performance related studies that can be performed using this test stand system include filter lifetime studies, filtering efficiency testing, media velocity testing, evaluations under high mass loading and high humidity conditions, and determination of the downstream particle size distributions. PMID

  4. High-efficiency particulate air filter test stand and aerosol generator for particle loading studies

    NASA Astrophysics Data System (ADS)

    Arunkumar, R.; Hogancamp, Kristina U.; Parsons, Michael S.; Rogers, Donna M.; Norton, Olin P.; Nagel, Brian A.; Alderman, Steven L.; Waggoner, Charles A.

    2007-08-01

    This manuscript describes the design, characterization, and operational range of a test stand and high-output aerosol generator developed to evaluate the performance of 30×30×29cm3 nuclear grade high-efficiency particulate air (HEPA) filters under variable, highly controlled conditions. The test stand system is operable at volumetric flow rates ranging from 1.5to12standardm3/min. Relative humidity levels are controllable from 5%-90% and the temperature of the aerosol stream is variable from ambient to 150°C. Test aerosols are produced through spray drying source material solutions that are introduced into a heated stainless steel evaporation chamber through an air-atomizing nozzle. Regulation of the particle size distribution of the aerosol challenge is achieved by varying source solution concentrations and through the use of a postgeneration cyclone. The aerosol generation system is unique in that it facilitates the testing of standard HEPA filters at and beyond rated media velocities by consistently providing, into a nominal flow of 7standardm3/min, high mass concentrations (˜25mg/m3) of dry aerosol streams having count mean diameters centered near the most penetrating particle size for HEPA filters (120-160nm). Aerosol streams that have been generated and characterized include those derived from various concentrations of KCl, NaCl, and sucrose solutions. Additionally, a water insoluble aerosol stream in which the solid component is predominantly iron (III) has been produced. Multiple ports are available on the test stand for making simultaneous aerosol measurements upstream and downstream of the test filter. Types of filter performance related studies that can be performed using this test stand system include filter lifetime studies, filtering efficiency testing, media velocity testing, evaluations under high mass loading and high humidity conditions, and determination of the downstream particle size distributions.

  5. Controlling urban air pollution caused by households: uncertainty, prices, and income.

    PubMed

    Chávez, Carlos A; Stranlund, John K; Gómez, Walter

    2011-10-01

    We examine the control of air pollution caused by households burning wood for heating and cooking in the developing world. Since the problem is one of controlling emissions from nonpoint sources, regulations are likely to be directed at household choices of wood consumption and combustion technologies. Moreover, these choices are subtractions from, or contributions to, the pure public good of air quality. Consequently, the efficient policy design is not independent of the distribution of household income. Since it is unrealistic to assume that environmental authorities can make lump sum income transfers part of control policies, efficient control of air pollution caused by wood consumption entails a higher tax on wood consumption and a higher subsidy for more efficient combustion technologies for higher income households. Among other difficulties, implementing a policy to promote the adoption of cleaner combustion technologies must overcome the seemingly paradoxical result that efficient control calls for higher technology subsidies for higher income households.

  6. Energy-Efficient Supermarket Heating, Ventilation, and Air Conditioning in Humid Climates in the United States

    SciTech Connect

    Clark, J.

    2015-03-01

    Supermarkets are energy-intensive buildings that consume the greatest amount of electricity per square foot of building of any building type in the United States and represent 5% of total U.S. commercial building primary energy use (EIA 2005). Refrigeration and heating, ventilation, and air-conditioning (HVAC) systems are responsible for a large proportion of supermarkets’ total energy use. These two systems sometimes work together and sometimes compete, but the performance of one system always affects the performance of the other. To better understand these challenges and opportunities, the Commercial Buildings team at the National Renewable Energy Laboratory investigated several of the most promising strategies for providing energy-efficient HVAC for supermarkets and quantified the resulting energy use and costs using detailed simulations. This research effort was conducted on behalf of the U.S. Department of Energy (DOE) Commercial Building Partnerships (CBP) (Baechler et al. 2012; Parrish et al. 2013; Antonopoulos et al. 2014; Hirsch et al. 2014). The goal of CBP was to reduce energy use in the commercial building sector by creating, testing, and validating design concepts on the pathway to net zero energy commercial buildings. Several CBP partners owned or operated buildings containing supermarkets and were interested in optimizing the energy efficiency of supermarket HVAC systems in hot-humid climates. These partners included Walmart, Target, Whole Foods Market, SUPERVALU, and the Defense Commissary Agency.

  7. A MultiAir®/MultiFuel Approach to Enhancing Engine System Efficiency

    SciTech Connect

    Reese, Ronald

    2015-05-20

    FCA US LLC (formally known as Chrysler Group LLC, and hereinafter “Chrysler”) was awarded an American Recovery and Reinvestment Act (ARRA) funded project by the Department of Energy (DOE) titled “A MultiAir®/MultiFuel Approach to Enhancing Engine System Efficiency” (hereinafter “project”). This award was issued after Chrysler submitted a proposal for Funding Opportunity Announcement DE-FOA- 0000079, “Systems Level Technology Development, Integration, and Demonstration for Efficient Class 8 Trucks (SuperTruck) and Advanced Technology Powertrains for Light-Duty Vehicles (ATP-LD).” Chrysler started work on this project on June 01, 2010 and completed testing activities on August 30, 2014. Overall objectives of this project were; Demonstrate a 25% improvement in combined Federal Test Procedure (FTP) City and Highway fuel economy over a 2009 Chrysler minivan; Accelerate the development of highly efficient engine and powertrain systems for light-duty vehicles, while meeting future emissions standards; and Create and retain jobs in accordance with the American Recovery and Reinvestment Act of 2009

  8. Multibar sawless lint cleaner: fiber quality analysis after 3rd year of field testing

    Technology Transfer Automated Retrieval System (TEKTRAN)

    After two years of field testing a prototype spiked-tooth lint cleaner, the Multibar Sawless Lint Cleaner (MBSLC), a final year of field evaluation was conducted at commercial cotton gin in West Texas located approximately 30 miles Southwest of Lubbock, Texas.The cotton lint cleaner was tested in a ...

  9. Nanofiber Air Filters with High-Temperature Stability for Efficient PM2.5 Removal from the Pollution Sources.

    PubMed

    Zhang, Rufan; Liu, Chong; Hsu, Po-Chun; Zhang, Chaofan; Liu, Nian; Zhang, Jinsong; Lee, Hye Ryoung; Lu, Yingying; Qiu, Yongcai; Chu, Steven; Cui, Yi

    2016-06-01

    Here, we developed high-efficiency (>99.5%) polyimide-nanofiber air filters for the high temperature PM2.5 removal. The polyimide nanofibers exhibited high thermal stability, and the PM2.5 removal efficiency was kept unchanged when temperature ranged from 25-370 °C. These filters had high air flux with very low pressure drop. They could continuously work for >120 h for PM2.5 index >300. A field-test showed that they could effectively remove >99.5% PM particles from car exhaust at high temperature.

  10. Cleaner Technology in the Hard Disk Drive Manufacturing Industry: A Case Study

    NASA Astrophysics Data System (ADS)

    Moolla, Premchai; Chompu-inwai, Rungchat

    2010-10-01

    The objectives of this research are to improve raw material and energy consumption efficiency, as well as reduce defects and the use of chemicals in the arm coil assembly process of hard disk drive manufacturing in the case study company by applying the Cleaner Technology concepts. The four main sequential steps used in this research were: (1) pre-assessment, (2) assessment, (3) feasibility study, and (4) implementation. In the first step, raw data, such as process flows, raw material usage and defects data were collected. In the second step, the loss during production and causes of loss were analyzed. Opportunities to reduce raw material, chemical and energy wastage could then be recommended. The next step was to evaluate the feasibility and potential benefits of a particular Cleaner Technology opportunity. Finally, in the last step, after a thorough evaluation and implementation of the opportunities to apply Cleaner Technology, the results showed that arm coil defects could be reduced by improving the production process using the ECRS technique. ECRS stands for Eliminate, Combine, Rearrange and Simplify. This improvement reduced arm coil defect rates from 0.48% to 0.15%, thus saving approximately 139,638 Thai Baht per month. In addition, production stoppage decision made by workers was used to increase employee involvement in defect detection. Allowing workers to participate in such a decision was an effective way to reduce defect rate and could motivate workers to produce a better quality job. This resulted in arm coil defects reducing from 0.41% to 0.025%, with about 74,562 Thai Baht per month saving. Additionally, an increase in the efficiency of electricity consumption occurred, by increasing the speed of the infrared oven conveyor belt, improving average productivity from 533 pieces/hour to 560 pieces/hour, without adversely affecting product costs and quality, thus producing products of up to the value of 206,242 Thai Baht per month. Furthermore, the new

  11. Influence Of Adsorbent Materials On Streamers Propagation In Air And Induced Chemical Efficiency

    NASA Astrophysics Data System (ADS)

    Guaitella, O.; Marinov, I.; Dong, B.; Rousseau, A.

    2010-07-01

    materials, give a new insight on the main role played by the dielectric in the development and the chemical efficiency of streamers ignited in DBD for air treatment.

  12. Alternative control technology document: Halogenated solvent cleaners. Final report

    SciTech Connect

    Not Available

    1989-08-01

    The document contains information on the use and control of halogenated solvents in solvent-cleaning applications. Described are the types of solvent cleaners manufactured, sources of solvent emissions, methods of controlling solvent emissions, and the costs associated with installation of control devices.

  13. PROCESS AND EQUIPMENT CHANGES FOR CLEANER PRODUCTION IN FEDERAL FACILITIES

    EPA Science Inventory

    The paper discusses process and equipment changes for cleaner production in federal facilities. During the 1990s, DoD and EPA conducted joint research and development, aimed at reducing the discharge of hazardous and toxic pollutants from military production and maintenance faci...

  14. Determination of Ammonia in Household Cleaners: An Instrumental Analysis Experiment.

    ERIC Educational Resources Information Center

    Graham, Richard C.; DePew, Steven

    1983-01-01

    Briefly discusses three techniques for assessing amount of ammonia present in household cleaners. Because of disadvantages with these methods, the thermometric titration technique is suggested in which students judge the best buy based on relative cost of ammonia present in samples. Laboratory procedures, typical results, and reactions involved…

  15. INNOVATIVE TECHNIQUE TO EVALUATE LINT CLEANER GRID BAR DESIGNS

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Photographic techniques were used to show the path that fibers attached to a gin saw take as they are drawn over a lint cleaner cleaning grid bar. A 1979 study showed that fibers were swept backwards, closer to the saw, as saw speed increased. The angle between the tip of the saw tooth and the fib...

  16. U.S. EPA POLLUTION PREVENTION AND CLEANER PRODUCTION TOOLS

    EPA Science Inventory

    This presentation was made at the 2002 annual meeting of the NATO CCMS Pilot Study on Clean Products and Processes, held on May 12-16, 2002 in Vilnius, Lithuania. The presentation covered six pollution prevention and cleaner production tools developed by NRMRL.

  17. Efficient air pollution regulation of coal-fired power in China

    NASA Astrophysics Data System (ADS)

    Feng, Therese

    This dissertation evaluates monetary external costs of electricity generation in the People's Republic of China and implications for efficient pollution control policy. It presents an integrated assessment of environmental damages of air emissions of a representative new coal-fired plant in urban areas of north and south China. The simulation evaluates the nature and magnitude of damages in China, transboundary effects in Japan and Korea, and global greenhouse gas warming impacts. The valuation is used to identify efficient abatement policy for Chinese plants over time; evaluate benefits of differentiated policies; and consider the importance of dynamic policy. Potential annual damages of operating a 600-MW power plant without controls in China today would be 43-45 million (U.S. 1995). Annual local damages of 37-40 million far exceed transboundary or greenhouse gas damages (1.4 million and $4.6 million respectively). The largest component of damages is the risk of human mortality and chronic morbidity from long-term exposure to fine particles. Efficient pollution control minimizes the sum of abatement costs and residual unabated damages. Because monetary damages reflect sufferers' willingness to pay to avoid environmental risks, the choice of efficient controls is fundamentally tied to societal values and preferences. The optimal path for Chinese abatement moves from modest dispersion measures at present to combined dispersion and emission controls approaching those of current-day United States, by 2050. The inclusion of transboundary and greenhouse damages does not substantively alter local policies. Welfare benefits are gained by differentiating abatement policy by pollutant, meteorological parameters, and by population density. An analysis of optimal one-time investment in abatement for a plant in a growing economy suggests that some investment is optimal at all incomes but no single level of abatement is suitable for all economies. Forward-looking policy

  18. Modeling of indoor air treatment of polychlorinated dibenzo-p-dioxins and dibenzofurans using high-efficiency particulate air-carbon filtration.

    PubMed

    Li, Hebi; Chen, Yongsheng; Crittenden, John; Hand, David; Taylor, Roy

    2006-08-01

    A high-efficiency particulate air (HEPA)-carbon filtration system was developed by the Access Business Group, LLC, to reduce the indoor levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The HEPA filter removes the particle-bound PCDD/Fs, and the carbon filter removes the gaseous fraction. Because of the toxicity of PCDD/Fs, it is very difficult to handle them in the laboratory. In this study, mathematical modeling was performed to evaluate the performance of the HEPA-carbon filtration system for PCDD/Fs removal and to optimize its design and operation. The model was calibrated with experimental data conducted with toluene in a sealed room. Model simulations with four selected congeners demonstrated that it takes approximately 1 hr for the indoor air treatment system to reach the maximum removal efficiency and that the carbon air filter has a life time of 10(7) yr for dioxin removal. Given a zero emission from the HEPA filter, the overall removal efficiency is 78.7% for 2,3,7,8-tetrachloro dibenzo-p-dioxins, 89.8% for octa-chlorodibenzodioxin, 78% for tetra-chlorodibenzofuran, and 89.8% for octa-chlorodibenzofuran. The larger the mass emission from the HEPA filter, the lower the overall removal efficiency, and the larger the ratio of the filter flow rate (Q(f)) to the room flow rate (Q), the higher the overall removal efficiency. When the ratio of Q(f)/Q is 15, an overall removal efficiency of 90% can be reached for all four of the selected compounds. The removal of the four selected compounds does not change as the relative humidity increases < or = 90%. PMID:16933648

  19. Modeling of indoor air treatment of polychlorinated dibenzo-p-dioxins and dibenzofurans using high-efficiency particulate air-carbon filtration.

    PubMed

    Li, Hebi; Chen, Yongsheng; Crittenden, John; Hand, David; Taylor, Roy

    2006-08-01

    A high-efficiency particulate air (HEPA)-carbon filtration system was developed by the Access Business Group, LLC, to reduce the indoor levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The HEPA filter removes the particle-bound PCDD/Fs, and the carbon filter removes the gaseous fraction. Because of the toxicity of PCDD/Fs, it is very difficult to handle them in the laboratory. In this study, mathematical modeling was performed to evaluate the performance of the HEPA-carbon filtration system for PCDD/Fs removal and to optimize its design and operation. The model was calibrated with experimental data conducted with toluene in a sealed room. Model simulations with four selected congeners demonstrated that it takes approximately 1 hr for the indoor air treatment system to reach the maximum removal efficiency and that the carbon air filter has a life time of 10(7) yr for dioxin removal. Given a zero emission from the HEPA filter, the overall removal efficiency is 78.7% for 2,3,7,8-tetrachloro dibenzo-p-dioxins, 89.8% for octa-chlorodibenzodioxin, 78% for tetra-chlorodibenzofuran, and 89.8% for octa-chlorodibenzofuran. The larger the mass emission from the HEPA filter, the lower the overall removal efficiency, and the larger the ratio of the filter flow rate (Q(f)) to the room flow rate (Q), the higher the overall removal efficiency. When the ratio of Q(f)/Q is 15, an overall removal efficiency of 90% can be reached for all four of the selected compounds. The removal of the four selected compounds does not change as the relative humidity increases < or = 90%.

  20. COREXIT 9580 shoreline cleaner: Development, application, and status

    SciTech Connect

    Canevari, G.P.; Fiocco, R.J.; Lessard, R.R.; Fingas, M.

    1995-06-01

    This paper will describe research on chemical beach cleaners for treatment of oiled shorelines that was initiated in support of the cleaning activities in Prince William Sound (PWS) following the Valdez oil spill in March 1989. The concept for using beach cleaners for shoreline cleanup is to apply a pre-soak to the weathered crude oil on shore and then flush with sea water to wash the oil into a boomed area for subsequent recovery. Criteria imposed on the use of chemical beach cleaners for the cleanup of the Valdez spill were: (1) effective rock cleaning agents should have very little or no toxicity to marine and terrestrial life, (2) there should be no dispersion of the oil washed from the shoreline into the water column; oil was to be recovered by techniques such as skimming or sorbents, and (3) the agents should be on the EPA National Contingency Plan (NCP) list. A laboratory-scale rock washing test was developed to measure cleaner effectiveness and dispersion. A large number of commercially available formulated products were evaluated, as well as development formulations. The commercial products included all of the available NCP-listed products which could function as cleaners. None of the commercial products completely satisfied all the requirements established by the agencies for beach cleaning. However, a new formula, called COREXIT 9580, consisting of two surfactants and a solvent was developed. It exhibited low fish toxicity, low dispersancy and effective rock cleaning capability. The paper reviews the laboratory and field testing to explore the potential use of the COREXIT 9580 to save and restore oiled vegetation.

  1. Energy-efficient air pollution controls for fossil-fueled plants: Technology assessment

    SciTech Connect

    Sayer, J.H.

    1995-06-01

    The 1990 Clean Air Act Amendments require most fossil-fuel fired power plants to reduce sulfur dioxide, nitrogen oxides, and particulate emissions. While emission-control equipment is available to help most of New York State`s 91 utility units in 31 power plants comply with the new regulations, technologies currently available consume energy, increase carbon dioxide emissions, reduce operating efficiency, and may produce large amounts of solid and/or semisolid byproducts that use additional energy for processing and disposal. This report discribes several pollution-control technologies that are more energy efficient compared to traditional technologies for controlling sulfur dioxide, nitrogen oxide, and particulates, that may have application in New York State. These technologies are either in commercial use, under development, or in the demonstration phase; This report also presents operating characteristics for these technologies and discusses solutions to dispose of pollution-control system byproducts. Estimated energy consumption for emission-control systems relative to a plant`s gross generating capacity is 3 to 5 for reducing up to 90% sulfur dioxide emissions from coal-fired plants. 0.5 to 2.5% for reducing nitrogen oxide emissions by up to 80% from all fossil-fuel fired plants; and 0.5 to 1.5 % for controlling particulate emissions from oil- and coal-fired plants. While fuel switching and/or cofiring with natural gas are options to reduce emissions, these techniques are not considered in this report; the discussion is limited to fossil-fueled steam-generating plants.

  2. Efficient algorithms for optimal arrival scheduling and air traffic flow management

    NASA Astrophysics Data System (ADS)

    Saraf, Aditya

    The research presented in this dissertation is motivated by the need for new, efficient algorithms for the solution of two important problems currently faced by the air-traffic control community: (i) optimal scheduling of aircraft arrivals at congested airports, and (ii) optimal National Airspace System (NAS) wide traffic flow management. In the first part of this dissertation, we present an optimal airport arrival scheduling algorithm, which works within a hierarchical scheduling structure. This structure consists of schedulers at multiple points along the arrival-route. Schedulers are linked through acceptance-rate constraints, which are passed up from downstream metering-points. The innovation in this scheduling algorithm is that these constraints are computed by using an Eulerian model-based optimization scheme. This rate computation removes inefficiencies introduced in the schedule through ad hoc acceptance-rate computations. The scheduling process at every metering-point uses its optimal acceptance-rate as a constraint and computes optimal arrival sequences by using a combinatorial search-algorithm. We test this algorithm in a dynamic air-traffic environment, which can be customized to emulate different arrival scenarios. In the second part of this dissertation, we introduce a novel two-level control system for optimal traffic-flow management. The outer-level control module of this two-level control system generates an Eulerian-model of the NAS by aggregating aircraft into interconnected control-volumes. Using this Eulerian model of the airspace, control strategies like Model Predictive Control are applied to find the optimal inflow and outflow commands for each control-volume so that efficient flows are achieved in the NAS. Each control-volume has its separate inner-level control-module. The inner-level control-module takes in the optimal inflow and outflow commands generated by the outer control-module as reference inputs and uses hybrid aircraft models to

  3. CMOS Amperometric ADC With High Sensitivity, Dynamic Range and Power Efficiency for Air Quality Monitoring.

    PubMed

    Li, Haitao; Boling, C Sam; Mason, Andrew J

    2016-08-01

    Airborne pollutants are a leading cause of illness and mortality globally. Electrochemical gas sensors show great promise for personal air quality monitoring to address this worldwide health crisis. However, implementing miniaturized arrays of such sensors demands high performance instrumentation circuits that simultaneously meet challenging power, area, sensitivity, noise and dynamic range goals. This paper presents a new multi-channel CMOS amperometric ADC featuring pixel-level architecture for gas sensor arrays. The circuit combines digital modulation of input currents and an incremental Σ∆ ADC to achieve wide dynamic range and high sensitivity with very high power efficiency and compact size. Fabricated in 0.5 [Formula: see text] CMOS, the circuit was measured to have 164 dB cross-scale dynamic range, 100 fA sensitivity while consuming only 241 [Formula: see text] and 0.157 [Formula: see text] active area per channel. Electrochemical experiments with liquid and gas targets demonstrate the circuit's real-time response to a wide range of analyte concentrations. PMID:27352395

  4. High-Efficiency Variable Dehumidification for Air Conditioners: ClimaStat

    SciTech Connect

    West, Michael K., Ph.D. P.E.

    2006-04-30

    Advantek has successfully developed the first low-cost technology offering significant improvement in both Seasonal Energy Efficiency (SEER) and comfort & humidity control. A production prototype was constructed based on a commercial roof top package unit. The prototype was operated under a wide range of psychrometric conditions. Test data was analyzed to identify refinements, which were implemented to further improve performance in an iterative procedure that resulted in a fully optimized technology. The latest results show an increase in dehumidification capacity of 56% with ClimaStat™ in full dehumidify mode vs. with ClimaStat™ off. Dehumidification improved by a factor of 1.7 to 1.9 – meaning that the unit can provide nearly twice the water removal per unit of sensible cooling load. Performance testing results have been consistent, verifiable and repeatable. . ClimaStat™ cost-effectively controls humidity on-demand and improves indoor air quality while reducing annual energy costs. Test data clearly shows that ClimaStat™ costs 20% to 60% less to operate. ClimaStat™ is ready for market.

  5. Efficiency of air/liquid interfaces in detaching bacteria from a surface

    NASA Astrophysics Data System (ADS)

    Khodaparast, Sepideh; Stone, Howard

    2015-11-01

    Gas/liquid interfaces are known to be significantly more effective than shear stress in detaching microscale colloids from substrates by inducing surface tension forces. Providing that a three-phase contact at the interface of a gas bubble, the liquid phase and the particle occurs, the magnitude of the surface tension force can potentially exceed by orders of magnitude the adhesion force, which keeps the micro particles on the surface. We investigate the ability of a moving air/liquid interface to stimulate the detachment of bacteria from a surface. Bacteria are micron-sized living organisms with strong tendency to attach to almost any substrate that they come into contact with. Attachment of bacteria on the surface is a complex process regulated by diverse characteristics of their growth medium, substrate, and cell surface. Moreover, once fixed on the surface, the microorganisms evolve in time to create intricate biofilm structures, which are highly challenging to be removed. The objective of this study to characterise the efficiency of this detachment process as a function of bacterial attachment as well as hydrodynamic parameters such the surface tension and the interface velocity. Swiss National Science Foundation P2ELP2-158896.

  6. Landscaping for energy efficiency

    SciTech Connect

    1995-04-01

    This publication by the National Renewable Energy Laboratory addresses the use of landscaping for energy efficiency. The topics of the publication include minimizing energy expenses; landscaping for a cleaner environment; climate, site, and design considerations; planning landscape; and selecting and planting trees and shrubs. A source list for more information on landscaping for energy efficiency and a reading list are included.

  7. Membrane Dehumidifier: High-Efficiency, On-Line Membrane Air Dehumidifier Enabling Sensible Cooling for Warm and Humid Climates

    SciTech Connect

    2010-09-01

    BEETIT Project: ADMA Products is developing a foil-like membrane for air conditioners that efficiently removes moisture from humid air. ADMA Products’s metal foil-like membrane consists of a paper thin, porous metal sheet coated with a layer of water-loving molecules. This new membrane allows water vapor to permeate across the membrane at high fluxes and at the same time, blocks air penetration efficiently resulting in high selectivity. The high selectivity of the membrane translates to less energy use, while the high permeation fluxes result in a more compact device. The new materials and the flat foil-like nature of the membrane facilitate the mass production of a low-coast compact dehumidification device

  8. Evaluation of the particle infiltration efficiency of three passive samplers and the PS-1 active air sampler

    NASA Astrophysics Data System (ADS)

    Markovic, Milos Z.; Prokop, Sebastian; Staebler, Ralf M.; Liggio, John; Harner, Tom

    2015-07-01

    The particle infiltration efficiencies (PIE) of three passive and one active air samplers were evaluated under field conditions. A wide-range particle spectrometer operating in the 250-4140 nm range was used to acquire highly temporally resolved particle-number and size distributions for the different samplers compared to ambient air. Overall, three of the four evaluated samplers were able to acquire a representative sample of ambient particles with PIEs of 91.5 ± 13.7% for the GAPS Network sampler, 103 ± 15.5% for the Lancaster University sampler, and 89.6 ± 13.4% for a conventional PS-1 high-volume active air sampler (Hi-Vol). Significantly (p = 0.05) lower PIE of 54 ± 8.0% was acquired for the passive sampler used under the MONET program. These findings inform the comparability and use of passive and active samplers for measuring particle-associated priority chemicals in air.

  9. Air pollution and chronic airway diseases: what should people know and do?

    PubMed

    Jiang, Xu-Qin; Mei, Xiao-Dong; Feng, Di

    2016-01-01

    The health effects of air pollution remain a public health concern worldwide. Exposure to air pollution has many substantial adverse effects on human health. Globally, seven million deaths were attributable to the joint effects of household and ambient air pollution. Subjects with chronic respiratory diseases such as chronic obstructive pulmonary disease (COPD) and asthma are especially vulnerable to the detrimental effects of air pollutants. Air pollution can induce the acute exacerbation of COPD and onset of asthma, increase the respiratory morbidity and mortality. The health effects of air pollution depend on the components and sources of pollutants, which varied with countries, seasons, and times. Combustion of solid fuels is a major source of air pollutants in developing countries. To reduce the detrimental effects of air pollution, people especially those with COPD or asthma should be aware of the air quality and take extra measures such as reducing the time outdoor and wearing masks when necessary. For reducing the air pollutants indoor, people should use clean fuels and improve the stoves so as to burn fuel more efficiently and vent emissions to the outside. Air cleaners that can improve the air quality efficiently are recommended.

  10. Air pollution and chronic airway diseases: what should people know and do?

    PubMed Central

    Jiang, Xu-Qin; Feng, Di

    2016-01-01

    The health effects of air pollution remain a public health concern worldwide. Exposure to air pollution has many substantial adverse effects on human health. Globally, seven million deaths were attributable to the joint effects of household and ambient air pollution. Subjects with chronic respiratory diseases such as chronic obstructive pulmonary disease (COPD) and asthma are especially vulnerable to the detrimental effects of air pollutants. Air pollution can induce the acute exacerbation of COPD and onset of asthma, increase the respiratory morbidity and mortality. The health effects of air pollution depend on the components and sources of pollutants, which varied with countries, seasons, and times. Combustion of solid fuels is a major source of air pollutants in developing countries. To reduce the detrimental effects of air pollution, people especially those with COPD or asthma should be aware of the air quality and take extra measures such as reducing the time outdoor and wearing masks when necessary. For reducing the air pollutants indoor, people should use clean fuels and improve the stoves so as to burn fuel more efficiently and vent emissions to the outside. Air cleaners that can improve the air quality efficiently are recommended. PMID:26904251

  11. Low-Pressure Generator Makes Cleanrooms Cleaner

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Scientists at NASA's Kennedy Space Center work in cleanrooms: laboratories with high degrees of cleanliness provided by strict control of particles such as dust, lint, or human skin. They are contaminant-free facilities, where the air is repeatedly filtered, and surfaces are smooth to prevent particles from getting lodged. Technicians working in these environments wear specially designed cleanroom "bunny suits" and booties over their street clothes, as well as gloves and face masks to avoid any contamination that may be imparted from the outside world. Even normal paper is not allowed in cleanrooms, only cleanroom low-particulate paper. These are sensitive environments where precision work, like the production of silicon chips or hard disk drives, is performed. Often in cleanrooms, positive air pressure is used to force particles outside of the isolated area. The air pressure in the Kennedy cleanrooms is monitored using high-accuracy, low-differential pressure transducers that require periodic calibration. Calibration of the transducers is a tricky business. In prior years, the analysis was performed by sending the transducers to the Kennedy Standards Laboratory, where a very expensive cross-floated, labor- intensive, dead-weight test was conducted. In the early 1990s, scientists at Kennedy determined to develop a technique and find equipment to perform qualification testing on new low-differential pressure transducers in an accurate, cost-effective manner onsite, without requiring an environmentally controlled room. They decided to use the highly accurate, cost-effective Setra Model C264 as the test transducer. For qualification testing of the Setra, though, a portable, lower-cost calibrator was needed that could control the differential pressure to a high degree of resolution and transfer the accuracy of the Standards Laboratory testing to the qualification testing. The researchers decided that, to generate the low-differential pressure setpoints needed for

  12. Green chemicals: Searching for cleaner solvents

    SciTech Connect

    Lucas, A.

    1994-10-05

    While increased pressure from EPA has solvents producers scrambling to find greener alternatives, many say the cost effectiveness and performance characteristics of traditional technologies are such that they will not disappear quickly. Though a variety of alternative {open_quotes}green{close_quotes} solvents have been developed and commercialized, better means of solvent recovery have also come along, ensuring continued use of many organic solvents. The 1990 Clean Air Act (CAA), designed to eliminate volatile organic compounds (VOCs), ozone depleters, and other hazardous air pollutants (HAPs), has put limits on many organic solvents. Those most under fire are chlorinated solvents, such as methylene chloride, 1,1,1 trichloroethylene (methyl chloroform), and chlorofluorocarbon (CFC)-113. Producers have been developing a variety of lower VOC solvents to replace those being phased out or regulated. Among those likely to experience most growth are aliphatic hydrocarbons to replace chlorinated solvents in cleaning applications. Growth is also expected for alcohols, esters, and glycol ethers for other end-use applications.

  13. Development of a highly efficient brushless dc motor utilizing both radial and axial air gaps

    NASA Astrophysics Data System (ADS)

    Kang, K. J.; Jang, G. H.; Sung, S. J.; Chang, J. H.

    2012-04-01

    This research proposes an effective structure for a brushless dc motor utilizing both radial and axial air gaps. The proposed motor generates torque in both the radial and axial air gaps, while the conventional motor generates torque only in the radial air gap. The proposed motor was optimized to minimize the electromagnetic loss of the motor to increase the effective air gap length and fill-factor of the coil while decreasing the saturation of the core at the same time. The electromagnetic loss was reduced by 35% in comparison with a conventional motor.

  14. Phylogenetic analysis and serotyping of Vibrio splendidus-related bacteria isolated from salmon farm cleaner fish.

    PubMed

    Gulla, Snorre; Sørum, Henning; Vågnes, Øyvind; Colquhoun, Duncan J

    2015-12-01

    Cleaner fish, i.e. various wrasse (Labridae) species and lumpsucker Cyclopterus lumpus, are to an increasing extent used for biocontrol of the salmon louse Lepeophtheirus salmonis in European salmon farming. Although efficient de-licers, cleaner fish mortality levels in salmon farms are often high. Bacterial infections are common, and Vibrio splendidus-related strains are frequently identified during diagnostic investigations. The population structure of 112 V. splendidus-related isolates, derived primarily from wrasse species, was investigated by means of multilocus sequence analysis using 5 housekeeping genes (rpoD, ftsZ, pyrH, rpoA and atpA). Most isolates were found to be closely related to the V. splendidus type strain, yet displayed extensive genetic microdiversity. Slide agglutination testing using polyclonal rabbit antisera further indicated O-antigen variability. Intra-outbreak genetic and antigenic diversity suggests direct infection from seawater, rather than fish-to-fish transmission, as the main route of infection. The variable nature of isolates involved complicates qualified selection of representative candidate strains, e.g. for infection and vaccine trials. PMID:26648104

  15. Phylogenetic analysis and serotyping of Vibrio splendidus-related bacteria isolated from salmon farm cleaner fish.

    PubMed

    Gulla, Snorre; Sørum, Henning; Vågnes, Øyvind; Colquhoun, Duncan J

    2015-12-01

    Cleaner fish, i.e. various wrasse (Labridae) species and lumpsucker Cyclopterus lumpus, are to an increasing extent used for biocontrol of the salmon louse Lepeophtheirus salmonis in European salmon farming. Although efficient de-licers, cleaner fish mortality levels in salmon farms are often high. Bacterial infections are common, and Vibrio splendidus-related strains are frequently identified during diagnostic investigations. The population structure of 112 V. splendidus-related isolates, derived primarily from wrasse species, was investigated by means of multilocus sequence analysis using 5 housekeeping genes (rpoD, ftsZ, pyrH, rpoA and atpA). Most isolates were found to be closely related to the V. splendidus type strain, yet displayed extensive genetic microdiversity. Slide agglutination testing using polyclonal rabbit antisera further indicated O-antigen variability. Intra-outbreak genetic and antigenic diversity suggests direct infection from seawater, rather than fish-to-fish transmission, as the main route of infection. The variable nature of isolates involved complicates qualified selection of representative candidate strains, e.g. for infection and vaccine trials.

  16. Removal of lead contaminant from Cr surfaces by using H2O2/EDTA cleaner solution.

    PubMed

    Hosseini, Seyed Ghorban; Gholivand, Khodayar; Khosravi, Mortezah; Toloti, Seyed Jafar Hosseini; Pandas, Hossein Momenizadeh

    2013-01-01

    All industrial processes especially metal cleaning procedures dealing with dangerous solutions should be used as little as possible and their emission into the aquatic environment should be controlled. In this study, in order to find a proper and efficient cleaning process, lead pollution was removed from the solid matrix by using a cleaner solution containing EDTA and H2O2 as chelating and oxidizing agents respectively. An orthogonal array design (OAD), OA9, was employed as a chemometric method for the optimization of the procedure. The results of experiment revealed that, lead pollution (-3 g) at the predicted optimum condition can be effectively removed from the solid matrix during 4 minutes. Cleaning quality was checked by SEM/EDAX, ICP and UV spectroscopy methods. Finally, the results of this investigation showed that H2O2/EDTA system can be considered as a novel, safe and an efficient cleaning solution, due to its proper processing parameters. PMID:23841357

  17. Removal of lead contaminant from Cr surfaces by using H2O2/EDTA cleaner solution.

    PubMed

    Hosseini, Seyed Ghorban; Gholivand, Khodayar; Khosravi, Mortezah; Toloti, Seyed Jafar Hosseini; Pandas, Hossein Momenizadeh

    2013-01-01

    All industrial processes especially metal cleaning procedures dealing with dangerous solutions should be used as little as possible and their emission into the aquatic environment should be controlled. In this study, in order to find a proper and efficient cleaning process, lead pollution was removed from the solid matrix by using a cleaner solution containing EDTA and H2O2 as chelating and oxidizing agents respectively. An orthogonal array design (OAD), OA9, was employed as a chemometric method for the optimization of the procedure. The results of experiment revealed that, lead pollution (-3 g) at the predicted optimum condition can be effectively removed from the solid matrix during 4 minutes. Cleaning quality was checked by SEM/EDAX, ICP and UV spectroscopy methods. Finally, the results of this investigation showed that H2O2/EDTA system can be considered as a novel, safe and an efficient cleaning solution, due to its proper processing parameters.

  18. Cleaner water using bimetallic nanoparticle catalysts

    SciTech Connect

    Wong, Michael S.; Alvarez, Pedro J.J.; Fang, Yu-Iun; Akçin, Nurgül; Nutt, Michael O.; Miller, Jeffrey T.; Heck, Kimberly N.

    2010-10-22

    Groundwater contaminated by hazardous chlorinated compounds, especially chlorinated ethenes, continues to be a significant environmental problem in industrialized nations. The conventional treatment methods of activated carbon adsorption and air-stripping successfully remove these compounds by way of transferring them from the water phase into the solid or gas phase. Catalysis is a promising approach to remove chlorinated compounds completely from the environment, by converting them into safer, non-chlorinated compounds. Palladium-based materials have been shown to be very effective as hydrodechlorination catalysts for the removal of chlorinated ethenes and other related compounds. However, relatively low catalytic activity and a propensity for deactivation are significant issues that prevent their widespread use in groundwater remediation. Palladium-on-gold bimetallic nanoparticles, in contrast, were recently discovered to exhibit superior catalyst activity and improved deactivation resistance. This new type of material is a significant next-step in the development of a viable hydrodechlorination catalysis technology.

  19. Summary of efficiency testing of standard and high-capacity high-efficiency particulate air filters subjected to simulated tornado depressurization and explosive shock waves

    SciTech Connect

    Smith, P.R.; Gregory, W.S.

    1985-04-01

    Pressure transients in nuclear facility air cleaning systems can originate from natural phenomena such as tornadoes or from accident-induced explosive blast waves. This study was concerned with the effective efficiency of high-efficiency particulate air (HEPA) filters during pressure surges resulting from simulated tornado and explosion transients. The primary objective of the study was to examine filter efficiencies at pressure levels below the point of structural failure. Both standard and high-capacity 0.61-m by 0.61-m HEPA filters were evaluated, as were several 0.2-m by 0.2-m HEPA filters. For a particular manufacturer, the material release when subjected to tornado transients is the same (per unit area) for both the 0.2-m by 0.2-m and the 0.61-m by 0.61-m filters. For tornado transients, the material release was on the order of micrograms per square meter. When subjecting clean HEPA filters to simulated tornado transients with aerosol entrained in the pressure pulse, all filters tested showed a degradation of filter efficiency. For explosive transients, the material release from preloaded high-capacity filters was as much as 340 g. When preloaded high-capacity filters were subjected to shock waves approximately 50% of the structural limit level, 1 to 2 mg of particulate was released.

  20. 40 CFR 1066.845 - AC17 air conditioning efficiency test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... voluntary procedure for measuring the net impact of air conditioner operation on CO2 emissions. See 40 CFR... solar heating is disabled for certain test intervals as described in this section. (d) Interior air... tests according to 40 CFR 86.132-00(a) through (g). If the vehicle has been tested within the last...

  1. Energy-Efficiency and Air-Pollutant Emissions-Reduction Opportunities for the Ammonia Industry in China

    SciTech Connect

    Ma, Ding; Hasanbeigi, Ali; Chen, Wenying

    2015-06-01

    As one of the most energy-intensive and polluting industries, ammonia production is responsible for significant carbon dioxide (CO2) and air-pollutant emissions. Although many energy-efficiency measures have been proposed by the Chinese government to mitigate greenhouse gas emissions and improve air quality, lack of understanding of the cost-effectiveness of such improvements has been a barrier to implementing these measures. Assessing the costs, benefits, and cost-effectiveness of different energy-efficiency measures is essential to advancing this understanding. In this study, a bottom-up energy conservation supply curve model is developed to estimate the potential for energy savings and emissions reductions from 26 energy-efficiency measures that could be applied in China’s ammonia industry. Cost-effective implementation of these measures saves a potential 271.5 petajoules/year for fuel and 5,443 gigawatt-hours/year for electricity, equal to 14% of fuel and 14% of electricity consumed in China’s ammonia industry in 2012. These reductions could mitigate 26.7 million tonnes of CO2 emissions. This study also quantifies the co-benefits of reducing air-pollutant emissions and water use that would result from saving energy in China’s ammonia industry. This quantitative analysis advances our understanding of the cost-effectiveness of energy-efficiency measures and can be used to augment efforts to reduce energy use and environmental impacts.

  2. Efficiency of Energy Use in the United States: Transportation, space heating, and air conditioning provide opportunities for large energy savings.

    PubMed

    Hirst, E; Moyers, J C

    1973-03-30

    We described three uses of energy for which greater efficiency is feasible: transportation, space heating, and air conditioning. Shifts to less energy-intensive transportation modes could substantially reduce energy consumption; the magnitude of such savings would, of course, depend on the extent of such shifts and possible load factor changes. The hypothetical transportation scenario described here results in a 22 percent savings in energy for transportation in 1970, a savings of 2800 trillion Btu. To the homeowner, increasing the amount of building insulation and, in some cases, adding storm windows would reduce energy consumption and provide monetary savings. If all homes in 1970 had the "economic optimum" amount of insulation, energy consumption for residential heating would have been 42 percent less than if the homes were insulated to meet the pre-1971 FHA standards, a savings of 3100 trillion Btu. Increased utilization of energy-efficient air conditioners and of building insulation would provide significant energy savings and help to reduce peak power demands during the summer. A 67 percent increase in energy efficiency for room air conditioners would have saved 15.8 billion kilowatt-hours in 1970. In conclusion, it is possible-from an engineering point of view-to effect considerable energy savings in the United States. Increases in the efficiency of energy use would provide desired end results with smaller energy inputs. Such measures will not reduce the level of energy consumption, but they could slow energy growth rates.

  3. Air Conditioning with Magnetic Refrigeration : An Efficient, Green Compact Cooling System Using Magnetic Refrigeration

    SciTech Connect

    2010-09-01

    BEETIT Project: Astronautics is developing an air conditioning system that relies on magnetic fields. Typical air conditioners use vapor compression to cool air. Vapor compression uses a liquid refrigerant to circulate within the air conditioner, absorb the heat, and pump the heat out into the external environment. Astronautics’ design uses a novel property of certain materials, called “magnetocaloric materials”, to achieve the same result as liquid refrigerants. These magnetocaloric materials essentially heat up when placed within a magnetic field and cool down when removed, effectively pumping heat out from a cooler to warmer environment. In addition, magnetic refrigeration uses no ozone-depleting gases and is safer to use than conventional air conditioners which are prone to leaks.

  4. Trochanteric Stress Fracture in a Female Window Cleaner

    PubMed Central

    Lee, Bong-Jin

    2016-01-01

    Stress fractures may occur at various sites in the femur including the head, neck, shaft, supracondylar and condylar regions. To the best of our knowledge, stress fracture occurring in the trochanteric region has not been previously reported. We report here a case of trochanteric stress fracture in a 53-year-old female window cleaner treated with hip nailing without adverse consequences. Careful consideration of this entity is needed when evaluating patients who have repetitive jumping up and down. PMID:27536646

  5. Bacterial contamination of commercial ear cleaners following routine home use.

    PubMed

    Bartlett, Sarah J; Rosenkrantz, Wayne S; Sanchez, Susan

    2011-12-01

    Ear cleaning solutions are designed for repeated use, which raises the possibility for bacterial contamination leading to recurrent or persistent infectious otitis. The purpose of this study was to investigate the prevalence of bacterial contamination of commercial ear cleaners following routine home use in dogs and to describe the characteristics that are associated with contamination. Used ear cleaner bottles and information regarding their use were obtained from canine owners visiting veterinary dermatologists. Both the bottle applicator tips and the solution contents were cultured for aerobic bacteria. Bacterial contamination was present on 10% of the bottle tips and in 2% of the solutions. Isolated bacteria included Staphylococcus pseudintermedius, Bacillus spp., coagulase-negative Staphylococcus spp., Micrococcus spp. and Burkholderia cepacia. The contamination rate was significantly higher on the applicator tips than in the solutions (P = 0.0076). The applicator tip contamination rate was significantly higher in expired samples (17%) than in-date samples (4%; P = 0.0277). The bottle sizes were significantly larger for the samples with contaminated applicator tips compared with noncontaminated tips (P = 0.0455). The contamination rate was significantly higher when Tris-EDTA was an ingredient. Cleanliness of the bottle, contact with the ear canal and infection status of the ear at time of culture had no bearing on the contamination rate. In summary, with routine home use of commercial ear cleaners, pathogenic bacterial contamination is of minor concern. This concern may increase when expired products or larger bottles of ear cleaner are used and when Tris-EDTA is an ingredient. PMID:21645141

  6. Urban air quality

    NASA Astrophysics Data System (ADS)

    Fenger, Jes

    Since 1950 the world population has more than doubled, and the global number of cars has increased by a factor of 10. In the same period the fraction of people living in urban areas has increased by a factor of 4. In year 2000 this will amount to nearly half of the world population. About 20 urban regions will each have populations above 10 million people. Seen over longer periods, pollution in major cities tends to increase during the built up phase, they pass through a maximum and are then again reduced, as abatement strategies are developed. In the industrialised western world urban air pollution is in some respects in the last stage with effectively reduced levels of sulphur dioxide and soot. In recent decades however, the increasing traffic has switched the attention to nitrogen oxides, organic compounds and small particles. In some cities photochemical air pollution is an important urban problem, but in the northern part of Europe it is a large-scale phenomenon, with ozone levels in urban streets being normally lower than in rural areas. Cities in Eastern Europe have been (and in many cases still are) heavily polluted. After the recent political upheaval, followed by a temporary recession and a subsequent introduction of new technologies, the situation appears to improve. However, the rising number of private cars is an emerging problem. In most developing countries the rapid urbanisation has so far resulted in uncontrolled growth and deteriorating environment. Air pollution levels are here still rising on many fronts. Apart from being sources of local air pollution, urban activities are significant contributors to transboundary pollution and to the rising global concentrations of greenhouse gasses. Attempts to solve urban problems by introducing cleaner, more energy-efficient technologies will generally have a beneficial impact on these large-scale problems. Attempts based on city planning with a spreading of the activities, on the other hand, may generate

  7. Biting cleaner fish use altruism to deceive image-scoring client reef fish.

    PubMed Central

    Bshary, Redouan

    2002-01-01

    Humans are more likely to help those who they have observed helping others previously. Individuals may thus benefit from being altruistic without direct reciprocity of recipients but due to gains in 'image' and associated indirect reciprocity. I suggest, however, that image-scoring individuals may be exploitable by cheaters if pay-offs vary between interactions. I illustrate this point with data on cleaner-client reef fish interactions. I show the following: (i) there is strong variation between cleaners with respect to cheating of clients (i.e. feeding on client tissue instead of parasites); (ii) clients approach cleaners, that they observe cooperating with their current client and avoid cleaners that they observe cheating; (iii) cleaners that cheat frequently are avoided more frequently than more cooperative cleaners (iv) cleaners that cheat frequently behave altruistically towards their smallest client species; (v) altruistic acts are followed by exploitative interactions. Thus, it appears that cleaners indeed have an image score, which selects for cooperative cleaners. However, cheating cleaners use altruism in potentially low-pay-off interactions to deceive and attract image-scoring clients that will be exploited. PMID:12396482

  8. Comparative in vitro antimicrobial efficacy of commercial ear cleaners.

    PubMed

    Swinney, Alison; Fazakerley, Jennifer; McEwan, Neil; Nuttall, Tim

    2008-12-01

    The aim of this study was to compare the antimicrobial efficacy of ear cleaners against Staphylococcus intermedius, Pseudomonas aeruginosa and Malassezia pachydermatis. Single isolates of each organism were incubated in duplicate at 38 degrees C for 30 min with each ear cleaner diluted 1/2 to 1/256 in phosphate-buffered saline. Positive and negative controls were included. Aliquots were then incubated for 16-18 h on sheep blood agar (bacteria) or for 3 days on Sabouraud's dextrose agar (Malassezia) at 38 degrees C. The lowest dilutions exhibiting 100% antimicrobial efficacy for S. intermedius were: Cleanaural Dog 1/32; Sancerum 1/16; Otoclean 1/4; EpiOtic 1/2; MalAcetic 1/2; and Triz Plus 1/2. The results for P. aeruginosa were Sancerum and Triz Plus 1/16; Cleanaural Dog and EpiOtic 1/8; Otoclean 1/4; and MalAcetic 1/2. Results for M. pachydermatis were: Cleanaural Dog 1/32; Sancerum, Otoclean, EpiOtic and Triz Plus 1/8; and MalAcetic 1/4. Cleanaural Cat, MalAcetic HC and Triz EDTA did not display any antimicrobial activity at any dilution. Antimicrobial activity appeared to be associated with the presence of isopropyl alcohol, parachlorometaxylenol and a low pH. The results of this study may help clinicians make evidence-based decisions when selecting ear cleaners for use in individual cases.

  9. Comparative in vitro antimicrobial efficacy of commercial ear cleaners.

    PubMed

    Swinney, Alison; Fazakerley, Jennifer; McEwan, Neil; Nuttall, Tim

    2008-12-01

    The aim of this study was to compare the antimicrobial efficacy of ear cleaners against Staphylococcus intermedius, Pseudomonas aeruginosa and Malassezia pachydermatis. Single isolates of each organism were incubated in duplicate at 38 degrees C for 30 min with each ear cleaner diluted 1/2 to 1/256 in phosphate-buffered saline. Positive and negative controls were included. Aliquots were then incubated for 16-18 h on sheep blood agar (bacteria) or for 3 days on Sabouraud's dextrose agar (Malassezia) at 38 degrees C. The lowest dilutions exhibiting 100% antimicrobial efficacy for S. intermedius were: Cleanaural Dog 1/32; Sancerum 1/16; Otoclean 1/4; EpiOtic 1/2; MalAcetic 1/2; and Triz Plus 1/2. The results for P. aeruginosa were Sancerum and Triz Plus 1/16; Cleanaural Dog and EpiOtic 1/8; Otoclean 1/4; and MalAcetic 1/2. Results for M. pachydermatis were: Cleanaural Dog 1/32; Sancerum, Otoclean, EpiOtic and Triz Plus 1/8; and MalAcetic 1/4. Cleanaural Cat, MalAcetic HC and Triz EDTA did not display any antimicrobial activity at any dilution. Antimicrobial activity appeared to be associated with the presence of isopropyl alcohol, parachlorometaxylenol and a low pH. The results of this study may help clinicians make evidence-based decisions when selecting ear cleaners for use in individual cases. PMID:19055612

  10. Comparison of soft toothbrush and new ultra-soft cleaner in ability to remove plaque from teeth.

    PubMed

    Stewart, William J; Gratzel, Kristen; Gearity, Erin J; Akerman, Meredith; Hill, Jennifer M

    2014-11-01

    In this single-blind, crossover study, the difference between a brushless tooth cleaner and a soft toothbrush was studied to compare plaque removal efficiency. The sample was composed of 15 human subjects who were categorized into two groups. Group 1 was composed of subjects randomly assigned to the brushless tooth cleaner for the first two weeks. Group 2 was composed of those randomly assigned to begin the study using the soft toothbrush. After two weeks of brushing with their assigned device, subjects returned to their normal modality to brush their teeth for one week. For the last two weeks of the study, subjects were told to brush with the opposite device they were originally assigned to at the beginning of the trial. Investigators recorded the subjects' gingival indices (based on probe depths) and Quigley scores (based on plaque indices using disclosing solution) at the beginning of week one, the end of week two, the end of week three and the end of week five. The main outcomes in this study were the Silness Loe Index (SLI) and the Quigley Hein Index (QHI). The SLI was assessed on the buccal, lingual, mesial and distal surfaces of six teeth, for a total of 24 surfaces. The QHI was assessed on the buccal and lingual surfaces of six teeth, for a total of 12 surfaces. Each index was measured at each visit by the sum total score divided by the total number of surfaces. The data were analyzed separately using a mixed-effects repeated measures analysis of variance (RMANOVA) for crossover designs. Results indicate that, according to the SLI, there is no significant difference between the two treatments after the first or second weeks. However, based on the QHI, statistically significant differences existed between the two treatments after week one and two. After week one, the soft toothbrush use had a higher QHI than the brushless tooth cleaner. After week two, the brushless tooth cleaner had a higher QHI than the soft toothbrush.

  11. Comparison of soft toothbrush and new ultra-soft cleaner in ability to remove plaque from teeth.

    PubMed

    Stewart, William J; Gratzel, Kristen; Gearity, Erin J; Akerman, Meredith; Hill, Jennifer M

    2014-11-01

    In this single-blind, crossover study, the difference between a brushless tooth cleaner and a soft toothbrush was studied to compare plaque removal efficiency. The sample was composed of 15 human subjects who were categorized into two groups. Group 1 was composed of subjects randomly assigned to the brushless tooth cleaner for the first two weeks. Group 2 was composed of those randomly assigned to begin the study using the soft toothbrush. After two weeks of brushing with their assigned device, subjects returned to their normal modality to brush their teeth for one week. For the last two weeks of the study, subjects were told to brush with the opposite device they were originally assigned to at the beginning of the trial. Investigators recorded the subjects' gingival indices (based on probe depths) and Quigley scores (based on plaque indices using disclosing solution) at the beginning of week one, the end of week two, the end of week three and the end of week five. The main outcomes in this study were the Silness Loe Index (SLI) and the Quigley Hein Index (QHI). The SLI was assessed on the buccal, lingual, mesial and distal surfaces of six teeth, for a total of 24 surfaces. The QHI was assessed on the buccal and lingual surfaces of six teeth, for a total of 12 surfaces. Each index was measured at each visit by the sum total score divided by the total number of surfaces. The data were analyzed separately using a mixed-effects repeated measures analysis of variance (RMANOVA) for crossover designs. Results indicate that, according to the SLI, there is no significant difference between the two treatments after the first or second weeks. However, based on the QHI, statistically significant differences existed between the two treatments after week one and two. After week one, the soft toothbrush use had a higher QHI than the brushless tooth cleaner. After week two, the brushless tooth cleaner had a higher QHI than the soft toothbrush. PMID:25675612

  12. Integrating NiCo Alloys with Their Oxides as Efficient Bifunctional Cathode Catalysts for Rechargeable Zinc-Air Batteries.

    PubMed

    Liu, Xien; Park, Minjoon; Kim, Min Gyu; Gupta, Shiva; Wu, Gang; Cho, Jaephil

    2015-08-10

    The lack of high-efficient, low-cost, and durable bifunctional electrocatalysts that act simultaneously for the oxygen reduction reaction (ORR) and the oxygen evolution reaction (OER) is currently one of the major obstacles to commercializing the electrical rechargeability of zinc-air batteries. A nanocomposite CoO-NiO-NiCo bifunctional electrocatalyst supported by nitrogen-doped multiwall carbon nanotubes (NCNT/CoO-NiO-NiCo) exhibits excellent activity and stability for the ORR/OER in alkaline media. More importantly, real air cathodes made from the bifunctional NCNT/CoO-NiO-NiCo catalysts further demonstrated superior performance to state-of-the-art Pt/C or Pt/C+IrO2 catalysts in primary and rechargeable zinc-air batteries. PMID:26118973

  13. Photosynthesis, transpiration and water use efficiencies of a plant canopy and plant leaves under restricted air current conditions

    NASA Astrophysics Data System (ADS)

    Kitaya, Yoshiaki; Shibuya, Toshio; Tsuruyama, Joshin

    A fundamental study was conducted to obtain the knowledge for culturing plants and exchanging gases with plants under restricted air circulation conditions in space agriculture. The effects of air velocities less than 1.3 m s-1 on net photosynthetic rates (Pn), transpiration rates (Tr) and Pn/Tr, water use efficiencies (WUE), of a canopy of cucumber seedlings and of single leaves of cucumber, sweet potato and barley were assessed with assimilation chamber methods in ground based experiments. The cucumber seedling canopy, which had a LAI of 1.4 and height of 0.1 m, was set in a wind tunnel installed in a plant canopy assimilation chamber. Each of the attached single leaves was set in a leaf assimilation chamber. The Pn and Tr of the plant canopy increased to 1.2 and 2.8 times, respectively, and WUE decreased to 0.4 times with increasing the air velocity from 0.02 to 1.3 m s-1. The Pn and Tr of the single leaves of all the species increased by 1.3-1.7 and 1.9-2.2 times, respectively, and WUE decreased to 0.6-0.8 times as the air velocity increased from 0.05 to 0.8 m s-1. The effect of air velocity was more significant on Tr than on Pn and thus WUE decreased with increasing air velocity in both the plant canopy and the individual leaves. The leaf boundary layer resistance was approximately proportional to the minus 1/3 power of the air velocity. Stomatal resistance was almost constant during the experiment. The CO2 concentrations in the sub-stomatal cavity in leaves of cucumber, sweet potato and barley, respectively, were 43, 31 and 58 mmol mol-1 lower at the air velocity of 0.05 m s-1 than at the air velocity of 0.8 m s-1, while the water vapor pressure in the sub-stomatal cavity was constant. We concluded that the change in the CO2 concentration in the sub-stomatal cavity was a cause of the different effect of the air velocity on Pn and Tr, and thus on WUE. The phenomenon will be more remarkable under restricted air convection conditions at lower gravity in space.

  14. In-place HEPA (high efficiency, particulate air) filter testing at Hanford: Operating experiences, calibrations, and lessons learned

    SciTech Connect

    Flores, D.S.; Decelis, D.G.

    1989-10-01

    High Efficiency, Particulate Air (HEPA) Filters provide a minimum of 99.97% removal efficiency for particles greater than or equal to .3 microns in diameter. Each HEPA filter installation at Hanford is, at specified intervals, functionally tested for leaks. The test procedure involves a dioctylphthalate (DOP) smoke generator and a calibrated airborne particle detector. The DOP generator produces smoke of a known quantitative particle size distribution upstream of the filter. The airborne particle detector is first placed upstream, and then downstream of the filter to determine percent penetration. The smoke generator is characterized using a calibrated laser spectrometer, and the particle detector is calibrated using a calibrated picoammeter. 2 refs., 4 figs.

  15. Perspective: Maintaining surface-phase purity is key to efficient open air fabricated cuprous oxide solar cells

    NASA Astrophysics Data System (ADS)

    Hoye, Robert L. Z.; Brandt, Riley E.; Ievskaya, Yulia; Heffernan, Shane; Musselman, Kevin P.; Buonassisi, Tonio; MacManus-Driscoll, Judith L.

    2015-02-01

    Electrochemically deposited Cu2O solar cells are receiving growing attention owing to a recent doubling in efficiency. This was enabled by the controlled chemical environment used in depositing doped ZnO layers by atomic layer deposition, which is not well suited to large-scale industrial production. While open air fabrication with atmospheric pressure spatial atomic layer deposition overcomes this limitation, we find that this approach is limited by an inability to remove the detrimental CuO layer that forms on the Cu2O surface. Herein, we propose strategies for achieving efficiencies in atmospherically processed cells that are equivalent to the high values achieved in vacuum processed cells.

  16. Use of naturally occurring radon progeny for in-place testing of high-efficiency particulate air filters

    SciTech Connect

    Newton, G.J.; Hoover, M.D.; Yeh, Hsu-Chi

    1997-12-01

    High-efficiency particulate air (HEPA) filters are routinely used to control emissions of radioactive particles from nuclear facilities. Because HEPA filters play a critical role in protecting members of the public and the environment, there are stringent requirements for verifying the efficiency of HEPA filters prior to their installation and during their use. Traditional methods for the performance tests involve introducing a challenge aerosol before the filter and comparing the concentration of particles before and after the filter. We describe a proof-of-principle test for evaluating use of naturally occurring radon progeny for testing HEPA filters.

  17. Active Flow Control Integrated Diffuser for increased Energy Efficiency in Variable Air Volume Systems

    NASA Astrophysics Data System (ADS)

    van der Schijff, Hermanus; Menicovich, David; Vollen, Jason; Amitay, Michael

    2013-11-01

    An experimental investigation was performed to study the application of flow control on an HVAC diffuser using synthetic jets distributed evenly along the diffuser edges. The study was conducted on 1:3 scale typical office space (150 ft2) , which included a simulated scale HVAC system supplied by compressed air. Two different jet momentum coefficients were investigated for two inlet flow rates of 40 and 60 CFM. The flow field was measured using hot wire anemometry and Particle Image Velocimetry. Current Variable Air Volume HVAC systems vary the incoming airflow to adjust to changing temperature conditions in the conditioned space. However, when the air flow rate drops below ideal, air distribution becomes inefficient. This study demonstrates the effectiveness of synthetic jets at controlling the incoming airflow and the distribution in the room, showing ability to affect throw coefficient parameters for different flow rates within the test chamber. The use of such devices has the potential to improve air quality and air distribution in building while simultaneously lowering energy demands of HVAC systems.

  18. A novel carbon black graphite hybrid air-cathode for efficient hydrogen peroxide production in bioelectrochemical systems

    NASA Astrophysics Data System (ADS)

    Li, Nan; An, Jingkun; Zhou, Lean; Li, Tian; Li, Junhui; Feng, Cuijuan; Wang, Xin

    2016-02-01

    Carbon black and graphite hybrid air-cathode is proved to be effective for H2O2 production in bioelectrochemical systems. The optimal mass ratio of carbon black to graphite is 1:5 with the highest H2O2 yield of 11.9 mg L-1 h-1 cm-2 (12.3 mA cm-2). Continuous flow is found to improve the current efficiency due to the avoidance of H2O2 accumulation. In the biological system, the highest H2O2 yield reaches 3.29 mg L-1h-1 (0.079 kg m-3day-1) with a current efficiency of 72%, which is higher than the abiotic system at the same current density. H2O2 produced in this system is mainly from the oxygen diffused through this air-cathode (>66%), especially when a more negative cathode potential is applied (94% at -1.0 V). This hybrid air-cathode has advantages of high H2O2 yield, high current density and no need of aeration, which make the synthesis of H2O2 more efficient and economical.

  19. New Plasma Technology for a Cleaner Environmant

    NASA Astrophysics Data System (ADS)

    Cohn, Daniel R.

    2000-04-01

    Onboard hydrogen production using compact plasmatron fuel converters has the potential to significantly improve the environmental quality of automobiles, trucks and buses. Plasmatron electric discharge technology has been employed to develop compact, rapid response and efficient devices which convert of a wide range of fuels into hydrogen-rich gas. Hydrogen rich gas has beneficial effects on engine operation and may also be useful in exhaust aftertreatment. Use of compact plasmatron fuel converters with present spark ignition engine technology could facilitate a 70-90% reduction in nitrogen oxide emissions from automobiles. Nitrogen oxides are a major ingredient in the production of smog. Hydrocarbon emissions could also be significantly reduced. Hydrogen-rich gas could also be employed to reduce pollution from Diesel engine vehicles. There could also be applications to hybrid and fuel cell powered vehicles. In addition, hydrogen generation using compact plasmatron fuel converters might be employed to facilitate the use of biomass derived fuels including oils by onboard conversion into hydrogen-rich gas. Use of biomass derived fuels on board could lead to a net reduction in CO2 production. Compact plasmatron fuel converters facilitate hydrogen production from partial oxidation of hydrocarbon fuels by providing increased reactive species, mixing and increased temperatures. Experimental studies of hydrogen production from compact plasmatron fuel converters and effects on laboratory engine operation will be discussed.

  20. Mega-supramolecules for safer, cleaner fuel

    NASA Astrophysics Data System (ADS)

    Kornfield, Julie

    Guided by the statistical mechanics of ring-chain equilibrium, we designed and synthesized polymers that self-assemble into ``mega-supramolecules'' (>=5,000 kg/mol) at low concentration (<=0.3%wt) in hydrocarbon liquids. Experimental results accord with model predictions that end-functional polymers, which distribute among cyclic and linear supramolecules, can form a significant population of mega-supramolecules at low total polymer concentration--if, and only if , the backbones are long (>400 kg/mol) and end-association strength is optimal (16-18kT). Hydrocarbon liquid fuels are the world's dominant power source (34% of global energy consumption). Transportation relies heavily on such liquids, presenting the risk of explosive post-impact fires. The collapse of the World Trade Center on September 11, 2001 inspired us to revisit polymers for mist control to mitigate post-impact fuel explosions. Rheological and both light and neutron scattering measurements of long end-functional polymers having polycyclooctadiene backbones and acid or amine end groups verify formation of mega-supramolecules. Post-impact flame propagations experiments show that mega-supramolecules control misting. Turbulent flow measurements show that mega-supramolecules reduce drag like ultra-long covalent polymers. With individual building blocks short enough to avoid hydrodynamic chain scission (400efficiency or emissions in diesel engines. In fact, they gave a 12% reduction in diesel soot. Thus, long end-associative polymers may open the way to fuel additives that reduce pollution and improve transportation safety and security.

  1. Active flow control integrated diffuser (afcid) for increased energy efficiency in variable air volume systems

    NASA Astrophysics Data System (ADS)

    Van Der Schijff, Hermanus P.

    Variable air volume (VAV) air terminals are designed to save energy by reducing airflow into a given space based on occupancy and required load. Systems are typically designed to operate at peak load, however as load is reduced, performance is compromised due to inadequate throw. As a result, fans are installed to adjust for the losses, negating many of the energy savings. Additionally flow is vectored by the use of vanes, a basic passive type of flow control. An experimental investigation was performed to study the application of flow control on that of a HVAC diffuser using synthetic jets distributed evenly along the diffuser edge parallel to the flow field. The study was conducted on a 1:3 scale typical office space (150 ft2), which included a simulated scale HVAC system supplied by compressed air. Two different jet blowing ratios were investigated for system loads of 60% and 90%. The flow field was established using hot wire anemometry and Particle Image Velocimetry (PIV). This study demonstrates the effectiveness of synthetic jet based active flow control at controlling airflow, showing ability to affect throw parameters for changing flow rates within the test chamber. Vectoring of up to 20% and improvement in jet spread of 200% was demonstrated. The use of such devices has the potential to improve air quality and air distribution in building while simultaneously lowering energy demands of HVAC systems.

  2. Air Cleaning Devices for HVAC Supply Systems in Schools. Technical Bulletin.

    ERIC Educational Resources Information Center

    Wheeler, Arthur E.

    Guidelines for maintaining indoor air quality in schools with HVAC air cleaning systems are provided in this document. Information is offered on the importance of air cleaning, sources of air contaminants and indoor pollutants, types of air cleaners and particulate filters used in central HVAC systems, vapor and gas removal, and performance…

  3. Cleaner fish use tactile dancing behavior as a preconflict management strategy.

    PubMed

    Grutter, Alexandra S

    2004-06-22

    The most commonly asked question about cooperative interactions is how they are maintained when cheating is theoretically more profitable. In cleaning interactions, where cleaners remove parasites from apparently cooperating clients, the classical question asked is why cleaner fish can clean piscivorous client fish without being eaten, a problem Trivers used to explain reciprocal altruism. Trivers suggested that predators refrain from eating cleaners only when the repeated removal of parasites by a particular cleaner results in a greater benefit than eating the cleaner. Although several theoretical models have examined cheating behavior in clients, no empirical tests have been done (but see Darcy ). It has been observed that cleaners are susceptible to predation. Thus, cleaners should have evolved strategies to avoid conflict or being eaten. In primates, conflicts are often resolved with conflict or preconflict management behavior. Here, I show that cleaner fish tactically stimulate clients while swimming in an oscillating "dancing" manner (tactile dancing) more when exposed to hungry piscivorous clients than satiated ones, regardless of the client's parasite load. Tactile dancing thus may function as a preconflict management strategy that enables cleaner fish to avoid conflict with potentially "dangerous" clients. PMID:15203000

  4. Cleaner fish use tactile dancing behavior as a preconflict management strategy.

    PubMed

    Grutter, Alexandra S

    2004-06-22

    The most commonly asked question about cooperative interactions is how they are maintained when cheating is theoretically more profitable. In cleaning interactions, where cleaners remove parasites from apparently cooperating clients, the classical question asked is why cleaner fish can clean piscivorous client fish without being eaten, a problem Trivers used to explain reciprocal altruism. Trivers suggested that predators refrain from eating cleaners only when the repeated removal of parasites by a particular cleaner results in a greater benefit than eating the cleaner. Although several theoretical models have examined cheating behavior in clients, no empirical tests have been done (but see Darcy ). It has been observed that cleaners are susceptible to predation. Thus, cleaners should have evolved strategies to avoid conflict or being eaten. In primates, conflicts are often resolved with conflict or preconflict management behavior. Here, I show that cleaner fish tactically stimulate clients while swimming in an oscillating "dancing" manner (tactile dancing) more when exposed to hungry piscivorous clients than satiated ones, regardless of the client's parasite load. Tactile dancing thus may function as a preconflict management strategy that enables cleaner fish to avoid conflict with potentially "dangerous" clients.

  5. Operationally efficient propulsion system study (OEPSS) data book. Volume 10; Air Augmented Rocket Afterburning

    NASA Technical Reports Server (NTRS)

    Farhangi, Shahram; Trent, Donnie (Editor)

    1992-01-01

    A study was directed towards assessing viability and effectiveness of an air augmented ejector/rocket. Successful thrust augmentation could potentially reduce a multi-stage vehicle to a single stage-to-orbit vehicle (SSTO) and, thereby, eliminate the associated ground support facility infrastructure and ground processing required by the eliminated stage. The results of this preliminary study indicate that an air augmented ejector/rocket propulsion system is viable. However, uncertainties resulting from simplified approach and assumptions must be resolved by further investigations.

  6. Cruise-Efficient Short Takeoff and Landing (CESTOL): Potential Impact on Air Traffic Operations

    NASA Technical Reports Server (NTRS)

    Couluris, G. J.; Signor, D.; Phillips, J.

    2010-01-01

    The National Aeronautics and Space Administration (NASA) is investigating technological and operational concepts for introducing Cruise-Efficient Short Takeoff and Landing (CESTOL) aircraft into a future US National Airspace System (NAS) civil aviation environment. CESTOL is an aircraft design concept for future use to increase capacity and reduce emissions. CESTOL provides very flexible takeoff, climb, descent and landing performance capabilities and a high-speed cruise capability. In support of NASA, this study is a preliminary examination of the potential operational impact of CESTOL on airport and airspace capacity and delay. The study examines operational impacts at a subject site, Newark Liberty Intemational Airport (KEWR), New Jersey. The study extends these KEWR results to estimate potential impacts on NAS-wide network traffic operations due to the introduction of CESTOL at selected major airports. These are the 34 domestic airports identified in the Federal Aviation Administration's Operational Evolution Plan (OEP). The analysis process uses two fast-time simulation tools to separately model local and NAS-wide air traffic operations using predicted flight schedules for a 24-hour study period in 2016. These tools are the Sen sis AvTerminal model and NASA's Airspace Concept Evaluation System (ACES). We use both to simulate conventional-aircraft-only and CESTOL-mixed-with-conventional-aircraft operations. Both tools apply 4-dimension trajectory modeling to simulate individual flight movement. The study applies AvTerminal to model traffic operations and procedures for en route and terminal arrival and departures to and from KEWR. These AvTerminal applications model existing arrival and departure routes and profiles and runway use configurations, with the assumption jet-powered, large-sized civil CESTOL aircraft use a short runway and standard turboprop arrival and departure procedures. With these rules, the conventional jet and CESTOL aircraft are procedurally

  7. Air pollution from aircraft. [jet exhaust - aircraft fuels/combustion efficiency

    NASA Technical Reports Server (NTRS)

    Heywood, J. B.; Chigier, N. A.

    1975-01-01

    A model which predicts nitric oxide and carbon monoxide emissions from a swirl can modular combustor is discussed. A detailed analysis of the turbulent fuel-air mixing process in the swirl can module wake region is reviewed. Hot wire anemometry was employed, and gas sampling analysis of fuel combustion emissions were performed.

  8. Energy efficiency and the environment: Innovative ways to improve air quality in the Los Angeles Basin

    SciTech Connect

    Ritschard, R.

    1993-02-01

    This paper focuses on novel, innovative approaches for reducing or delaying the production of photochemical smog in the Los Angeles Basin. These approaches include modifying the surface characteristics of the basin by increasing surface albedo and an extensive tree-planting program. The changes in surface conditions are designed to reduce the basin air temperatures, especially during the summer months, which will result in two possible effects. First, a decrease in temperature would lead to a reduction in energy use with an associated decline in emissions of nitrogen oxides (NO{sub x}) and a lowering of evaporative emission of reactive organic gases. Reductions in these smog precursors could improve the air quality of the basin without imposing additional emissions regulations. The second effect is associated with the possible causal relationship between air temperature and smog formation (i.e., lower temperatures and lower incidence of smog). Since this approach to mitigating air emissions is broad, the studies to date have concentrated on how changes in surface characteristics affect the meteorological conditions of the basin and on how these meteorological changes subsequently affect smog production. A geographic information system database of key surface characteristics (i.e., vegetative cover, albedo, moisture availability, and roughness) was compiled, and these characteristics were evaluated using prognostic meteorological models. The results of two- and three-dimensional meteorological simulations will be presented and discussed in this paper.

  9. Energy efficiency and the environment: Innovative ways to improve air quality in the Los Angeles Basin

    SciTech Connect

    Ritschard, R.

    1993-02-01

    This paper focuses on novel, innovative approaches for reducing or delaying the production of photochemical smog in the Los Angeles Basin. These approaches include modifying the surface characteristics of the basin by increasing surface albedo and an extensive tree-planting program. The changes in surface conditions are designed to reduce the basin air temperatures, especially during the summer months, which will result in two possible effects. First, a decrease in temperature would lead to a reduction in energy use with an associated decline in emissions of nitrogen oxides (NO[sub x]) and a lowering of evaporative emission of reactive organic gases. Reductions in these smog precursors could improve the air quality of the basin without imposing additional emissions regulations. The second effect is associated with the possible causal relationship between air temperature and smog formation (i.e., lower temperatures and lower incidence of smog). Since this approach to mitigating air emissions is broad, the studies to date have concentrated on how changes in surface characteristics affect the meteorological conditions of the basin and on how these meteorological changes subsequently affect smog production. A geographic information system database of key surface characteristics (i.e., vegetative cover, albedo, moisture availability, and roughness) was compiled, and these characteristics were evaluated using prognostic meteorological models. The results of two- and three-dimensional meteorological simulations will be presented and discussed in this paper.

  10. Using radon-222 as indicator for the evaluation of the efficiency of groundwater remediation by in situ air sparging.

    PubMed

    Schubert, Michael; Schmidt, Axel; Müller, Kai; Weiss, Holger

    2011-02-01

    A common approach for remediation of groundwater contamination with volatile organic compounds (VOCs) is contaminant stripping by means of in situ air sparging (IAS). For VOC stripping, pressurized air is injected into the contaminated groundwater volume, followed by the extraction of the contaminant-loaded exhaust gas from the vadose soil zone and its immediate on-site treatment. Progress assessment of such remediation measure necessitates information (i) on the spatial range of the IAS influence and (ii) on temporal variations of the IAS efficiency. In the present study it was shown that the naturally occurring noble gas radon can be used as suitable environmental tracer for achieving the related spatial and temporal information. Due to the distinct water/air partitioning behaviour of radon and due to its straightforward on-site detectability, the radon distribution pattern in the groundwater can be used as appropriate measure for assessing the progression of an IAS measure as a function of space and time. The presented paper discusses both the theoretical background of the approach and the results of an IAS treatment accomplished at a VOC contaminated site lasting six months, during which radon was applied as efficiency indicator.

  11. Assemblies of protective anion exchange membrane on air electrode for its efficient operation in aqueous alkaline electrolyte

    NASA Astrophysics Data System (ADS)

    Bertolotti, Bruno; Chikh, Linda; Vancaeyzeele, Cédric; Alfonsi, Séverine; Fichet, Odile

    2015-01-01

    Aqueous alkaline metal-air batteries represent promising energy storage devices when supplied with atmospheric air. However, under this condition, the air electrode shows a very short life time (i.e. 50 h of operation in 5 M LiOH at -10 mA cm-2), mainly due to the precipitation of carbonates inside the electrode porosity. The air electrode can then be protected by an anion exchange membrane on the electrolyte side. In this paper, we demonstrate that the efficiency of this protective membrane depends on the assembly method on the electrode. When a modified poly(epichlorohydrin) (PECH) network is synthesized directly on the electrode, the polymer seeps inside the electrode porosity, and a suitable interface inducing negligible additional polarization in comparison with classical pressure-assembled membranes is obtained. This protected electrode shows improved stability of up to 160 h of operation in 5 M LiOH. This performance is improved to 350 h by adjusting the conductivity and the ionic exchange capacity. Finally, the interest of interpenetrating polymer network (IPN) architecture compared to a single network is confirmed. Indeed, an electrode protected with a PECH/poly(2-hydroxyethyl methacrylate) (PHEMA) IPN is stable for 650 h in 5 M LiOH. In addition, degradation process becomes reversible since the assembly can be regenerated, which is not possible for the bare electrode.

  12. Energy efficiency assessment methods and tools evaluation. Bolling Air Force Base. Revision 1

    SciTech Connect

    McMordie, K.L.; Richman, E.E.; Keller, J.M.; Dixon, D.R.

    1995-05-01

    The goal of the U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP) is to facilitate energy-efficiency improvements at federal facilities. This is accomplished by a balanced program of technology development, facility assessment, and use of cost-sharing procurement mechanisms. Technology development focuses upon the tools, software, and procedures used to identify and evaluate energy-efficiency technologies and improvements. For facility assessment, FEMP provides metering equipment and trained analysts to federal agencies exhibiting a commitment to improve energy use efficiency. To assist in procurement of energy-efficiency measures, FEMP helps federal agencies devise and implement performance contracting and utility demand-side management strategies. Pacific Northwest Laboratory (PNL) supports the FEMP mission of energy systems modernization. Under this charter, the Laboratory and its contractors work with federal facility energy managers to assess and implement energy-efficiency improvements at federal facilities nationwide.

  13. Design study of the KAGRA output mode cleaner

    NASA Astrophysics Data System (ADS)

    Kumeta, Ayaka; Bond, Charlotte; Somiya, Kentaro

    2015-02-01

    Most second-generation gravitational-wave detectors employ an optical resonator called an output mode cleaner (OMC), which filters out junk light from the signal and the reference light, before it reaches the detection photodiode located at the asymmetric port of the large-scale interferometer. The optical parameters of the OMC should be carefully chosen to satisfy the requirements to filter out unwanted light whilst transmitting the gravitational-wave signal. We use the simulation program FINESSE and realistic mirror phase maps that have the same surface quality as the KAGRA test masses to find out a proper design of the KAGRA OMC.

  14. Efficient new process for the desulfurization of mixtures of air and hydrogen sulfide via a dielectric barrier discharge plasma

    NASA Astrophysics Data System (ADS)

    Dahle, S.

    2015-10-01

    The efficient removal of hydrogen sulfide, H2S, from streams of H2S in air via a dielectric barrier discharge (DBD) plasma has been investigated using a quadrupole mass spectrometer. A suitable plasma device with a reservoir for storing sorbent powder of various kinds within the plasma region was constructed. Plasma treatments of gas streams with high concentrations of hydrogen sulfide in air yielded a removal of more than 98% of the initial hydrogen sulfide and a deposition of sulfur at the surface of the dielectric, while small amounts of sulfur dioxide were generated. The presence of calcium carbonate within the plasma region of the DBD device resulted in the removal of over 99% of the initial hydrogen sulfide content and the removal of 98% of the initial sulfur dioxide impurities from the gas mixture.

  15. Hydrogen oxidation mechanism with applications to (1) the chaperon efficiency of carbon dioxide and (2) vitiated air testing

    NASA Technical Reports Server (NTRS)

    Brabbs, Theodore A.; Lezberg, Erwin A.; Bittker, David A.; Robertson, Thomas F.

    1987-01-01

    Ignition delay times for the hydrogen/oxygen/carbon dioxide/argon system were obtained behind reflected shock waves. A detailed kinetic mechanism modeled the experimental hydrogen/oxygen data, Skinner and Ringrose's high-pressure data, and Slack and Grillo's hydrogen/air data. A carbon dioxide chaperon efficiency of 7.0 +/- 0.2 was determined. The reaction pathway H2O yields H2O2 yields OH yields H was required to model the high-pressure data. It is suggested that some of the lowest temperature data points (1.0 and 0.5 atm) for Slack and Grillo's hydrogen/air experiments are in error. It was found that the technique of simplifying a detailed kinetic mechanism for a limited range of experimental data may render the model useless for other test conditions.

  16. High-efficiency, gas-fired, heat-pipe, warm-air heating system

    NASA Astrophysics Data System (ADS)

    Becker, F. E.; Zakak, A. I.; Searight, E. F.

    1983-01-01

    Four residential heat pipe furnaces were installed at selected test sites early in 1982. Each furnace unit operated at 100,000 Btu/hr heat input with a steady state efficiency of 86 percent. Two of the units were life cycle tested in laboratories; no major difficulties were encountered during their operation. Two additional furnaces were tested in homes. Field test performance confirmed that a steady state efficiency of 86 percent and a seasonal efficiency of 82-83 percent were obtained. A major furnace manufacturer has been licensed to manufacture and sell the heat pipe furnace developed by Thermo Electron under GRI sponsorship. A manufacturing prototype furnace was designed and fabricated taking into consideration the production capabilities of the manufacturer. The furnace is rated at 105,000 Btu/hr heat input and has a steady state efficiency of 85 percent. A field test was begun to continue through the 1982-83 heating season.

  17. Efficient Computation of Separation-Compliant Speed Advisories for Air Traffic Arriving in Terminal Airspace

    NASA Technical Reports Server (NTRS)

    Sadovsky, Alexander V.; Davis, Damek; Isaacson, Douglas R.

    2012-01-01

    A class of problems in air traffic management asks for a scheduling algorithm that supplies the air traffic services authority not only with a schedule of arrivals and departures, but also with speed advisories. Since advisories must be finite, a scheduling algorithm must ultimately produce a finite data set, hence must either start with a purely discrete model or involve a discretization of a continuous one. The former choice, often preferred for intuitive clarity, naturally leads to mixed-integer programs, hindering proofs of correctness and computational cost bounds (crucial for real-time operations). In this paper, a hybrid control system is used to model air traffic scheduling, capturing both the discrete and continuous aspects. This framework is applied to a class of problems, called the Fully Routed Nominal Problem. We prove a number of geometric results on feasible schedules and use these results to formulate an algorithm that attempts to compute a collective speed advisory, effectively finite, and has computational cost polynomial in the number of aircraft. This work is a first step toward optimization and models refined with more realistic detail.

  18. Reflector for efficient coupling of a laser beam to air or other fluids

    DOEpatents

    Kare, J.T.

    1992-10-06

    A reflector array is disclosed herein that provides a controlled region or regions of plasma breakdowns from a laser beam produced at a remotely-based laser source. The plasma may be applied to produce thrust to propel a spacecraft, or to diagnose a laser beam, or to produce shock waves. The spacecraft propulsion system comprises a reflector array attached to the vehicle. The reflector array comprises a plurality of reflectors spaced apart on a reflective surface, with each reflector acting as an independent focusing mirror. The reflectors are spaced closely together to form a continuous or partially-continuous surface. The reflector array may be formed from a sheet of reflective material, such as copper or aluminum. In operation, a beam of electromagnetic energy, such as a laser beam, is directed at the reflectors which focus the reflected electromagnetic energy at a plurality of regions off the surface. The energy concentrated in the focal region causes a breakdown of the air or other fluid in the focal region, creating a plasma. Electromagnetic energy is absorbed in the plasma and it grows in volume, compressing and heating the adjacent fluid thereby providing thrust. Laser pulses may be applied repetitively. After each such thrust pulse, fresh air can be introduced next to the surface either laterally, or through a perforated surface. If air or some other gas or vapor is supplied, for example from a tank carried on board a vehicle, this invention may also be used to provide thrust in a vacuum environment. 10 figs.

  19. Reflector for efficient coupling of a laser beam to air or other fluids

    DOEpatents

    Kare, Jordin T.

    1992-01-01

    A reflector array is disclosed herein that provides a controlled region or regions of plasma breakdowns from a laser beam produced at a remotely-based laser source. The plasma may be applied to produce thrust to propel a spacecraft, or to diagnose a laser beam, or to produce shockwaves. The spacecraft propulsion system comprises a reflector array attached to the vehicle. The reflector array comprises a plurality of reflectors spaced apart on a reflective surface, with each reflector acting as an independent focusing mirror. The reflectors are spaced closely together to form a continuous or partially-continuous surface. The reflector array may be formed from a sheet of reflective material, such as copper or aluminum. In operation, a beam of electromagnetic energy, such as a laser beam, is directed at the reflectors which focus the reflected electromagnetic energy at a plurality of regions off the surface. The energy concentrated in the focal region causes a breakdown of the air or other fluid in the focal region, creating a plasma. Electromagnetic energy is absorbed in the plasma and it grows in volume, compressing and heating the adjacent fluid thereby providing thrust. Laser pulses may be applied repetitively. After each such thrust pulse, fresh air can be introduced next to the surface either laterally, or through a perforated surface. If air or some other gas or vapor is supplied, for example from a tank carried on board a vehicle, this invention may also be used to provide thrust in a vacuum environment.

  20. Evaluation of the effect of media velocity on filter efficiency and most penetrating particle size of nuclear grade high-efficiency particulate air filters.

    PubMed

    Alderman, Steven L; Parsons, Michael S; Hogancamp, Kristina U; Waggoner, Charles A

    2008-11-01

    High-efficiency particulate air (HEPA) filters are widely used to control particulate matter emissions from processes that involve management or treatment of radioactive materials. Section FC of the American Society of Mechanical Engineers AG-1 Code on Nuclear Air and Gas Treatment currently restricts media velocity to a maximum of 2.5 cm/sec in any application where this standard is invoked. There is some desire to eliminate or increase this media velocity limit. A concern is that increasing media velocity will result in higher emissions of ultrafine particles; thus, it is unlikely that higher media velocities will be allowed without data to demonstrate the effect of media velocity on removal of ultrafine particles. In this study, the performance of nuclear grade HEPA filters, with respect to filter efficiency and most penetrating particle size, was evaluated as a function of media velocity. Deep-pleat nuclear grade HEPA filters (31 cm x 31 cm x 29 cm) were evaluated at media velocities ranging from 2.0 to 4.5 cm/sec using a potassium chloride aerosol challenge having a particle size distribution centered near the HEPA filter most penetrating particle size. Filters were challenged under two distinct mass loading rate regimes through the use of or exclusion of a 3 microm aerodynamic diameter cut point cyclone. Filter efficiency and most penetrating particle size measurements were made throughout the duration of filter testing. Filter efficiency measured at the onset of aerosol challenge was noted to decrease with increasing media velocity, with values ranging from 99.999 to 99.977%. The filter most penetrating particle size recorded at the onset of testing was noted to decrease slightly as media velocity was increased and was typically in the range of 110-130 nm. Although additional testing is needed, these findings indicate that filters operating at media velocities up to 4.5 cm/sec will meet or exceed current filter efficiency requirements. Additionally

  1. Evaluation of the effect of media velocity on filter efficiency and most penetrating particle size of nuclear grade high-efficiency particulate air filters.

    PubMed

    Alderman, Steven L; Parsons, Michael S; Hogancamp, Kristina U; Waggoner, Charles A

    2008-11-01

    High-efficiency particulate air (HEPA) filters are widely used to control particulate matter emissions from processes that involve management or treatment of radioactive materials. Section FC of the American Society of Mechanical Engineers AG-1 Code on Nuclear Air and Gas Treatment currently restricts media velocity to a maximum of 2.5 cm/sec in any application where this standard is invoked. There is some desire to eliminate or increase this media velocity limit. A concern is that increasing media velocity will result in higher emissions of ultrafine particles; thus, it is unlikely that higher media velocities will be allowed without data to demonstrate the effect of media velocity on removal of ultrafine particles. In this study, the performance of nuclear grade HEPA filters, with respect to filter efficiency and most penetrating particle size, was evaluated as a function of media velocity. Deep-pleat nuclear grade HEPA filters (31 cm x 31 cm x 29 cm) were evaluated at media velocities ranging from 2.0 to 4.5 cm/sec using a potassium chloride aerosol challenge having a particle size distribution centered near the HEPA filter most penetrating particle size. Filters were challenged under two distinct mass loading rate regimes through the use of or exclusion of a 3 microm aerodynamic diameter cut point cyclone. Filter efficiency and most penetrating particle size measurements were made throughout the duration of filter testing. Filter efficiency measured at the onset of aerosol challenge was noted to decrease with increasing media velocity, with values ranging from 99.999 to 99.977%. The filter most penetrating particle size recorded at the onset of testing was noted to decrease slightly as media velocity was increased and was typically in the range of 110-130 nm. Although additional testing is needed, these findings indicate that filters operating at media velocities up to 4.5 cm/sec will meet or exceed current filter efficiency requirements. Additionally

  2. Efficiency of automotive cabin air filters to reduce acute health effects of diesel exhaust in human subjects

    PubMed Central

    Rudell, B.; Wass, U.; Horstedt, P.; Levin, J. O.; Lindahl, R.; Rannug, U.; Sunesson, A. L.; Ostberg, Y.; Sandstrom, T.

    1999-01-01

    OBJECTIVES: To evaluate the efficiency of different automotive cabin air filters to prevent penetration of components of diesel exhaust and thereby reduce biomedical effects in human subjects. Filtered air and unfiltered diluted diesel exhaust (DDE) were used as negative and positive controls, respectively, and were compared with exposure to DDE filtered with four different filter systems. METHODS: 32 Healthy non- smoking subjects (age 21-53) participated in the study. Each subject was exposed six times for 1 hour in a specially designed exposure chamber: once to air, once to unfiltered DDE, and once to DDE filtered with the four different cabin air filters. Particle concentrations during exposure to unfiltered DDE were kept at 300 micrograms/m3. Two of the filters were particle filters. The other two were particle filters combined with active charcoal filters that might reduce certain gaseous components. Subjective symptoms were recorded and nasal airway lavage (NAL), acoustic rhinometry, and lung function measurements were performed. RESULTS: The two particle filters decreased the concentrations of diesel exhaust particles by about half, but did not reduce the intensity of symptoms induced by exhaust. The combination of active charcoal filters and a particle filter significantly reduced the symptoms and discomfort caused by the diesel exhaust. The most noticable differences in efficacy between the filters were found in the reduction of detection of an unpleasant smell from the diesel exhaust. In this respect even the two charcoal filter combinations differed significantly. The efficacy to reduce symptoms may depend on the abilities of the filters investigated to reduce certain hydrocarbons. No acute effects on NAL, rhinometry, and lung function variables were found. CONCLUSIONS: This study has shown that the use of active charcoal filters, and a particle filter, clearly reduced the intensity of symptoms induced by diesel exhaust. Complementary studies on vehicle

  3. Eggplant-derived microporous carbon sheets: towards mass production of efficient bifunctional oxygen electrocatalysts at low cost for rechargeable Zn-air batteries.

    PubMed

    Li, Bing; Geng, Dongsheng; Lee, Xinjing Shannon; Ge, Xiaoming; Chai, Jianwei; Wang, Zhijuan; Zhang, Jie; Liu, Zhaolin; Hor, T S Andy; Zong, Yun

    2015-05-25

    We report 2D microporous carbon sheets with high surface area, derived from eggplant via simple carbonization and KOH activation, as low cost yet efficient bifunctional catalysts for high performance rechargeable zinc-air batteries.

  4. Eggplant-derived microporous carbon sheets: towards mass production of efficient bifunctional oxygen electrocatalysts at low cost for rechargeable Zn-air batteries.

    PubMed

    Li, Bing; Geng, Dongsheng; Lee, Xinjing Shannon; Ge, Xiaoming; Chai, Jianwei; Wang, Zhijuan; Zhang, Jie; Liu, Zhaolin; Hor, T S Andy; Zong, Yun

    2015-05-25

    We report 2D microporous carbon sheets with high surface area, derived from eggplant via simple carbonization and KOH activation, as low cost yet efficient bifunctional catalysts for high performance rechargeable zinc-air batteries. PMID:25920952

  5. Survival and stress responses of E. coli exposed to alkaline cleaners

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Studies were undertaken to evaluate the effects of alkaline cleaners commonly used in food processing environments on survival and stress responses of the foodborne pathogen Escherichia coli O157:H7. Alkaline cleaners containing either sodium hydroxide or potassium hydroxide and hypochlorite had gre...

  6. TESTING ANTIMICROBIAL CLEANER EFFICACY ON GYPSUM WALLBOARD CONTAMINATED WITH STACHYBOTRYS CHARTARUM

    EPA Science Inventory

    Reducing occupant exposure to indoor mold growth is the goal of this research, through the efficacy testing of antimicrobial cleaners. Often mold contaminated building materials are not properly removed, but instead surface cleaners are applied in an attempt to alleviate the prob...

  7. Mutualistic cleaner fish initiate trait-mediated indirect interactions by influencing the behaviour of coral predators.

    PubMed

    Adam, Thomas C

    2012-05-01

    1. Indirect interactions resulting from changes in organismal traits such as behaviour [i.e. trait-mediated indirect interactions (TMIIs)] are widespread in biological communities, yet few studies have explored the potential for mutualisms to initiate TMIIs. 2. This study used a combination of behavioural observations and manipulative field experiments to investigate potential TMIIs resulting from a mutualism between specialized cleaner fish and the 'clients' that visit cleaners for the removal of ectoparasites. 3. Behavioural observations indicate that the bluestreak cleaner wrasse, Labroides dimidiatus, increases local predation pressure on corals at cleaner stations by attracting corallivorous butterflyfish to their territories. 4. Observations of the ornate butterflyfish, Chaetodon ornatissimus, suggest a trade-off between seeking cleaning and foraging; individuals decreased their foraging rate at cleaner stations and shifted their diet to include a greater proportion of less preferred prey items. Nonetheless, predation pressure on corals was higher at cleaner stations because the spatial response of butterflyfish to cleaners more than compensated for their lower foraging rates. 5. The results of a field experiment suggest that the greater predation pressure observed at cleaner stations may be sufficient to reduce the growth rate of the unpreferred coral Porites rus. 6. Together, these results emphasize the need to consider mutualists as potential initiators of TMIIs and highlight the importance of integrating individual movement into conceptual analyses of TMIIs.

  8. Perspective: Maintaining surface-phase purity is key to efficient open air fabricated cuprous oxide solar cells

    SciTech Connect

    Hoye, Robert L. Z. E-mail: jld35@cam.ac.uk; Ievskaya, Yulia; MacManus-Driscoll, Judith L. E-mail: jld35@cam.ac.uk; Brandt, Riley E.; Buonassisi, Tonio; Heffernan, Shane; Musselman, Kevin P.

    2015-02-01

    Electrochemically deposited Cu{sub 2}O solar cells are receiving growing attention owing to a recent doubling in efficiency. This was enabled by the controlled chemical environment used in depositing doped ZnO layers by atomic layer deposition, which is not well suited to large-scale industrial production. While open air fabrication with atmospheric pressure spatial atomic layer deposition overcomes this limitation, we find that this approach is limited by an inability to remove the detrimental CuO layer that forms on the Cu{sub 2}O surface. Herein, we propose strategies for achieving efficiencies in atmospherically processed cells that are equivalent to the high values achieved in vacuum processed cells.

  9. Energy efficiency of engines and appliances for transport on land, water, and in air.

    PubMed

    Furfari, Samuele

    2016-01-01

    The transport sector is fundamental for the economy but also for personal life. With a growing population and the globalization process, it is not surprising that the demand of transport is set to grow in the near future and certainly until 2050. This paper focuses on the huge potential of progress in the sector of technology for transport. As the principal sector for transport will remain on roads, the paper emphasizes the progress in the automotive sector. Since car manufacturers are investing massively into research and technology development to offer ever more efficient cars--not only energy efficient but also efficient in terms of safety and comfort--the car of tomorrow will be very different from the present one. The increasing role of electronics in cars will synergistically cooperate with that of so-called smart cities. The potential development of methane in the transport sector, mainly used for heavy transportation is discussed.

  10. Low air exchange rate causes high indoor radon concentration in energy-efficient buildings.

    PubMed

    Vasilyev, A V; Yarmoshenko, I V; Zhukovsky, M V

    2015-06-01

    Since 1995, requirements on energy-efficient building construction were established in Russian Building Codes. In the course of time, utilisation of such technologies became prevailing, especially in multi-storey building construction. According to the results of radon survey in buildings constructed meeting new requirements on energy efficiency, radon concentration exceeds the average level in early-constructed buildings. Preponderance of the diffusion mechanism of radon entry in modern multi-storey buildings has been experimentally established. The experimental technique of the assessment of ventilation rate in dwellings under real conditions was developed. Based on estimates of average ventilation rate, it was approved that measures to increase energy efficiency lead to reduction in ventilation rate and accumulation of higher radon concentrations indoors. Obtained ventilation rate values have to be considered as extremely low.

  11. Energy efficiency of engines and appliances for transport on land, water, and in air.

    PubMed

    Furfari, Samuele

    2016-01-01

    The transport sector is fundamental for the economy but also for personal life. With a growing population and the globalization process, it is not surprising that the demand of transport is set to grow in the near future and certainly until 2050. This paper focuses on the huge potential of progress in the sector of technology for transport. As the principal sector for transport will remain on roads, the paper emphasizes the progress in the automotive sector. Since car manufacturers are investing massively into research and technology development to offer ever more efficient cars--not only energy efficient but also efficient in terms of safety and comfort--the car of tomorrow will be very different from the present one. The increasing role of electronics in cars will synergistically cooperate with that of so-called smart cities. The potential development of methane in the transport sector, mainly used for heavy transportation is discussed. PMID:26667061

  12. Efficient butt-coupling of surface plasmons on a silver-air interface

    NASA Astrophysics Data System (ADS)

    Fisher, Caitlin; Botten, Lindsay C.; Poulton, Christopher G.; McPhedran, Ross C.; de Sterke, C. Martijn

    2015-12-01

    Butt-coupling of light into a surface plasmon is a simple and compact coupling method with a range of potential uses in photonic circuitry. Although butt-coupling has been successfully implemented in many coupling configurations, the coupling effectiveness is not fully understood. Here, we present a semi-analytical study which models the coupling efficiency of an incident beam into a surface plasmon on silver in the presence of loss using an projection method in one dimension. We find that the coupling efficiencies for silver between the wavelengths of 0:38 - 1:6 μm reach 77 - 88% with optimum incident beam parameters.

  13. Air stable organic salt as an n-type dopant for efficient and stable organic light-emitting diodes.

    PubMed

    Bin, Zhengyang; Duan, Lian; Qiu, Yong

    2015-04-01

    Air-stable and low-temperature-evaporable n-type dopants are highly desired for efficient and stable organic light-emitting diodes (OLEDs). In this work, 2-(2-Methoxyphenyl)-1,3-dimethyl-1H-benzoimidazol-3-ium iodide (o-MeO-DMBI-I), a thermally decomposable precursor of organic radical o-MeO-DMBI, has been employed as a novel n-type dopant in OLEDs, because of its air stability, low decomposition temperature, and lack of atom diffusion. The n-type electrical doping is evidenced by the rapid increase in current density of electron-only devices and the large improvement in conductivity, originated from increased electron concentration in electron-transport layer (ETL) and reduced electron injection barrier. A highly efficient and stable OLED is created using o-MeO-DMBI as an n-type dopant in Bphen. Compared with the control device with its high-temperature-evaporable n-type dopant cesium carbonate (Cs2CO3), o-MeO-DMBI-doped device showed an incredible boom in current efficiency from 28.6 to 42.2 cd/A. Moreover, the lifetime (T(70%)) of o-MeO-DMBI-doped device is 45 h, more than 20 times longer than that of the Cs2CO3-doped device (2 h). The enhanced efficiency and stability are attributed to the improved balance of holes and electrons in the emissive layer, and the eliminated atom diffusion of cesium. PMID:25768295

  14. Energy-efficient wastewater treatment via the air-based, hybrid membrane biofilm reactor (hybrid MfBR).

    PubMed

    Aybar, M; Pizarro, G; Boltz, J P; Downing, L; Nerenberg, R

    2014-01-01

    We used modeling to predict the energy and cost savings associated with the air-based, hybrid membrane-biofilm reactor (hybrid MfBR). This process is obtained by replacing fine-bubble diffusers in conventional activated sludge with air-supplying, hollow-fiber membrane modules. Evaluated processes included removal of chemical oxygen demand (COD), combined COD and total nitrogen (TN) removal, and hybrid growth (biofilm and suspended). Target concentrations of COD and TN were based on high-stringency water reuse scenarios. Results showed reductions in power requirements as high as 86%. The decrease mainly resulted from the dramatically lower air flows for the MBfR, resulting from its higher oxygen-transfer efficiencies. When the MBfR was used for COD and TN removal, savings up to US$200/1,000 m(3) of treated water were predicted. Cost savings were highly sensitive to the costs of the membrane modules and electrical power. The costs were also very sensitive to membrane oxidation flux for ammonia, and the membrane life. These results suggest the hybrid MBfR may provide significant savings in energy and costs. Further research on the identified key parameters can help confirm these modeling predictions and facilitate scale-up.

  15. Energy-efficient wastewater treatment via the air-based, hybrid membrane biofilm reactor (hybrid MfBR).

    PubMed

    Aybar, M; Pizarro, G; Boltz, J P; Downing, L; Nerenberg, R

    2014-01-01

    We used modeling to predict the energy and cost savings associated with the air-based, hybrid membrane-biofilm reactor (hybrid MfBR). This process is obtained by replacing fine-bubble diffusers in conventional activated sludge with air-supplying, hollow-fiber membrane modules. Evaluated processes included removal of chemical oxygen demand (COD), combined COD and total nitrogen (TN) removal, and hybrid growth (biofilm and suspended). Target concentrations of COD and TN were based on high-stringency water reuse scenarios. Results showed reductions in power requirements as high as 86%. The decrease mainly resulted from the dramatically lower air flows for the MBfR, resulting from its higher oxygen-transfer efficiencies. When the MBfR was used for COD and TN removal, savings up to US$200/1,000 m(3) of treated water were predicted. Cost savings were highly sensitive to the costs of the membrane modules and electrical power. The costs were also very sensitive to membrane oxidation flux for ammonia, and the membrane life. These results suggest the hybrid MBfR may provide significant savings in energy and costs. Further research on the identified key parameters can help confirm these modeling predictions and facilitate scale-up. PMID:24759536

  16. 42 CFR 84.181 - Non-powered air-purifying particulate filter efficiency level determination.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... equivalent. The DOP aerosol shall have a particle size distribution with count median diameter of 0.185 ±0... further decrease in efficiency. (g) The sodium chloride test aerosol shall have a particle size distribution with count median diameter of 0.075 ±0.020 micrometer and a standard geometric deviation...

  17. 42 CFR 84.181 - Non-powered air-purifying particulate filter efficiency level determination.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... equivalent. The DOP aerosol shall have a particle size distribution with count median diameter of 0.185 ±0... further decrease in efficiency. (g) The sodium chloride test aerosol shall have a particle size distribution with count median diameter of 0.075 ±0.020 micrometer and a standard geometric deviation...

  18. 42 CFR 84.181 - Non-powered air-purifying particulate filter efficiency level determination.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... equivalent. The DOP aerosol shall have a particle size distribution with count median diameter of 0.185 ±0... further decrease in efficiency. (g) The sodium chloride test aerosol shall have a particle size distribution with count median diameter of 0.075 ±0.020 micrometer and a standard geometric deviation...

  19. 42 CFR 84.181 - Non-powered air-purifying particulate filter efficiency level determination.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... equivalent. The DOP aerosol shall have a particle size distribution with count median diameter of 0.185 ±0... further decrease in efficiency. (g) The sodium chloride test aerosol shall have a particle size distribution with count median diameter of 0.075 ±0.020 micrometer and a standard geometric deviation...

  20. 42 CFR 84.181 - Non-powered air-purifying particulate filter efficiency level determination.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... equivalent. The DOP aerosol shall have a particle size distribution with count median diameter of 0.185 ±0... further decrease in efficiency. (g) The sodium chloride test aerosol shall have a particle size distribution with count median diameter of 0.075 ±0.020 micrometer and a standard geometric deviation...

  1. Compressed Air System Modifications Improve Efficiency at a Plastics Blow Molding Plant (Southeastern Container Plant)

    SciTech Connect

    2001-06-01

    This case study is one in a series on industrial firms who are implementing energy efficient technologies and system improvements into their manufacturing processes. This case study documents the activities, savings, and lessons learned on the plastics blow molding plant project.

  2. Compressed Air System Enhancement Increase Efficiency and Provides Energy Savings at a Circuit Board Manufacturer

    SciTech Connect

    2001-06-01

    This case study is one in a series on industrial firms who are implementing energy efficient technologies and system improvements into their manufacturing processes. This case study documents the activities, savings, and lessons learned on the circuit board manufacturer (Sanmina Plant) project.

  3. Field Demonstration of a High-Efficiency Packaged Rooftop Air Conditioning Unit at Fort Gordon, Augusta, GA

    SciTech Connect

    Armstrong, Peter R.; Sullivan, Gregory P.; Parker, Graham B.

    2006-03-31

    As part of a larger program targeting the market transformation of packaged rooftop air conditioning, five high-efficiency rooftop air conditioning products were selected in 2002 by the U.S. Department of Energy (DOE) under the Unitary Air Conditioner (UAC) Technology Procurement (http://www.pnl.gov/uac). In February 2003, Fort Gordon in Augusta, Georgia was chosen as the demonstration site. With the goal of validating the field performance and operation of one of the awarded products, a 10-ton high-efficiency packaged rooftop unit (RTU) manufactured by Global Energy Group (GEG) was installed at Fort Gordon in October 2003. Following equipment installation, power metering, air- and refrigerant-side instrumentation was installed on the GEG RTU and a 4-year old typical-efficiency 20-ton RTU manufactured by AAON . The GEG and AAON units were instrumented identically and operated May through July, 2005, to observe performance under a range of conditions. Based on the data collected as part of this demonstration, the GEG equipment performed at least 8% better in stage-1 (single compressor running) cooling and at least 16% better in stage-2 (both compressors running) than the baseline AAON equipment. Performance comparisons are based on what we call application EER normalized to equivalent specific fan power. The full-load, specific-fan-power-normalized application EERs at ARI design conditions were 10.48 Btu/Wh for the GEG and 9.00 Btu/Wh for the baseline machine. With a cost premium of nearly 50%, and slightly higher maintenance costs, the life-cycle cost analysis shows that the GEG technology pays for itself--a positive net-present value (NPV)--only in climates and buildings with long cooling seasons. Manufacture of this equipment on a larger scale can be expected to reduce costs to the point where it is more broadly cost-effective. The assumed 10-ton baseline and new-technology unit costs are $3824.00 and $5525.00 respectively. If the new technology cost is assumed

  4. Evaluation of Ag nanoparticle coated air filter against aerosolized virus: Anti-viral efficiency with dust loading.

    PubMed

    Joe, Yun Haeng; Park, Dae Hoon; Hwang, Jungho

    2016-01-15

    In this study, the effect of dust loading on the anti-viral ability of an anti-viral air filter was investigated. Silver nanoparticles approximately 11 nm in diameter were synthesized via a spark discharge generation system and were used as anti-viral agents coated onto a medium air filter. The pressure drop, filtration efficiency, and anti-viral ability of the filter against aerosolized bacteriophage MS2 virus particles were tested with dust loading. The filtration efficiency and pressure drop increased with dust loading, while the anti-viral ability decreased. Theoretical analysis of anti-viral ability with dust loading was carried out using a mathematical model based on that presented by Joe et al. (J. Hazard. Mater.; 280: 356-363, 2014). Our model can be used to compare anti-viral abilities of various anti-viral agents, determine appropriate coating areal density of anti-viral agent on a filter, and predict the life cycle of an anti-viral filter. PMID:26434534

  5. Extraction of semivolatile organic compounds from high-efficiency particulate air (HEPA) filters by supercritical carbon dioxide

    SciTech Connect

    Schilling, J.B.

    1997-09-01

    Supercritical fluid extraction (SFE) using unmodified carbon dioxide has been explored as an alternative method for the extraction of semivolatile organic compounds from high-efficiency particulate air (HEPA) filters. HEPA filters provide the final stage of containment on many exhaust systems in US Department of Energy (DOE) facilities by preventing the escape of chemical and radioactive materials entrained in the exhausted air. The efficiency of the filters is tested by the manufacturer and DOE using dioctylphthalate (DOP), a substance regulated by the US Environmental Protection Agency under the Resource Conservation and Recovery Act. Therefore, the filters must be analyzed for semivolatile organics before disposal. Ninety-eight acid, base, and neutral semivolatile organics were spiked onto blank HEPA material and extracted using SFE, Soxhlet, automated Soxhlet, and sonication techniques. The SFE conditions were optimized using a Dionex SFE-703 instrument. Average recoveries for the 98 semivolatile compounds are 82.7% for Soxhlet, 74.0% for sonication, 70.2% for SFE, and 62.9% for Soxtec. Supercritical fluid extraction reduces the extraction solvent volume to 10--15 mL, a factor of 20--30 less than Soxhlet and more than 5 times less than Soxtec and sonication. Extraction times of 30--45 min are used compared to 16--18 h for Soxhlet extraction.

  6. Evaluation of clay-TiO2 nanocomposite efficiency on the photocatalytic elimination of a model hydrophobic air pollutant.

    NASA Astrophysics Data System (ADS)

    Cervini-Silva, J.; Kibanova, D.; Destaillats, H.

    2008-12-01

    Clay-supported TiO2 photocatalysts can potentially improve the performance of air treatment technologies due to enhanced adsorption and reactivity of volatile organic compounds (VOCs). In this study, a bench-top photocatalytic flow reactor was used to evaluate hectorite-TiO2 and kaolinite-TiO2, two novel composite materials synthesized in our laboratory. Toluene, a model hydrophobic VOC and a common indoor air pollutant, was introduced in the air stream at realistic concentrations and reacted under UVA (?max = 365 nm) or UVC (?max = 254 nm) irradiation. The UVC lamp presented secondary emission at 185 nm, leading to the formation of ozone and other short-lived reactive species. Performance of clay-TiO2 composites was compared with that of pure TiO2 (Degussa P25) and with UV irradiation in the absence of photocatalyst under identical conditions. Films of clay-TiO2 composites and of P25 were prepared by a dip- coating method on the surface of Raschig rings placed inside the flow reactor. An upstream toluene concentration of 150 ppbv was generated by diluting a constant vapor flow with dry air, or with humid air at 10, 33, and 66 % relative humidity (RH). Toluene concentrations downstream were determined by collecting Tenax-TA ® sorbent tubes and subsequent thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) analysis. The fraction of toluene removed, %R, and the reaction rate, Tr, were calculated for each experimental condition from the concentration changes registered with and without UV irradiation. Use of UVC light (UV/TiO2/O3) led to overall higher reactivity, which can be partially attributed to contribution of gas phase reactions by O3 and other short-lived species. When the reaction rate was normalized by the light irradiance, Tr/Iλ, the UV/TiO2 reaction under UVA irradiation was more efficient for samples with a higher content of TiO2 (P25 and Hecto-TiO2), but not for Kao-TiO2. Considering the effect of relative humidity, in all cases reaction

  7. AUTOMOTIVE DIESEL MAINTENANCE 1. UNIT II, MAINTAINING THE AIR SYSTEM--DETROIT DIESEL ENGINES.

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF THE DIESEL ENGINE AIR SYSTEM. TOPICS ARE (1) OPERATION AND FUNCTION, (2) AIR CLEANER, (3) AIR SHUT-DOWN HOUSING, (4) EXHAUST SYSTEM, (5) BLOWER, (6) TURBOCHARGER, AND (7) TROUBLE-SHOOTING TIPS ON THE AIR SYSTEM. THE MODULE CONSISTS OF A…

  8. Development of a high-efficiency, gas-fired, heat pipe, warm-air heating system

    NASA Astrophysics Data System (ADS)

    Feldman, S.; Becker, F.

    1985-01-01

    With the introduction by Borg-Warner of the Heatpipe Furnace, one of the major goals of this program was achieved. This milestone was reached after a 105,000 Btu/hr, 85 percent efficient manufacturing prototype heat pipe furnace was designed, fabricated, and tested by Thermo Electron. Other prototype units of different capacities were also designed. The prototypes underwent extensive field testing and in-house accelerated life-cycle testing, indicating that they were reliable, safe, and cost-competitive. Specific issues like freeze protection and oil contamination were addressed. Two different prototype ultrahigh-efficiency condensing furnaces were designed, fabricated and tested. One approach utilized a fluorocarbon-filled heat pipe as a secondary-stage heat exchanger; the other used a plate finned tube coil as the heat exchanger.

  9. Automated Cooperative Trajectories for a More Efficient and Responsive Air Transportation System

    NASA Technical Reports Server (NTRS)

    Hanson, Curt

    2015-01-01

    The NASA Automated Cooperative Trajectories project is developing a prototype avionics system that enables multi-vehicle cooperative control by integrating 1090 MHz ES ADS-B digital communications with onboard autopilot systems. This cooperative control capability will enable meta-aircraft operations for enhanced airspace utilization, as well as improved vehicle efficiency through wake surfing. This briefing describes the objectives and approach to a flight evaluation of this system planned for 2016.

  10. Electret Polyvinylidene Fluoride Nanofibers Hybridized by Polytetrafluoroethylene Nanoparticles for High-Efficiency Air Filtration.

    PubMed

    Wang, Shan; Zhao, Xinglei; Yin, Xia; Yu, Jianyong; Ding, Bin

    2016-09-14

    Airborne particulate matter (PM) pollution has become a severe environmental concern calling for electret fibrous materials with high filtration efficiency and low pressure drop. However, restraining the dissipation of the electric charges in service to ensure the stabilized electrostatic force of the fibers for effectively adsorbing particles is extremely important and also challenging. Herein, we report novel electret nanofibrous membranes with numerous charges and desirable charge stability using polyvinylidene fluoride (PVDF) as the matrix polymer and polytetrafluoroethylene nanoparticles (PTFE NPs) as an inspiring charge enhancer through the in situ charging technology of electrospinning. Benefiting from the employment of PTFE NPs and optimized injection energy, the fibrous membranes are endowed with elevated surface potentials from 0.42 to 3.63 kV and reduced decrement of charges from 75.4 to 17.5%, which contribute to the ameliorative stability of filtration efficiency. Significantly, an electret mechanism is proposed, while deepened depth of the energy level and incremental polarized dipole charges with increasing PTFE NP concentrations and injection energy have been confirmed through the measurement of open-circuit thermally stimulated discharge and surface potential decay. Ultimately, the resultant fibrous membrane exhibited a high filtration efficiency of 99.972%, a low pressure drop of 57 Pa, a satisfactory quality factor of 0.14 Pa(-1), and superior long-term service performance. The successful fabrication of such an intriguing material may provide a new approach for the design and development of electret materials for PM2.5 governance. PMID:27552028

  11. Fuel Efficient Strategies for Reducing Contrail Formations in United States Air Space

    NASA Technical Reports Server (NTRS)

    Sridhar, Banavar; Chen, Neil Y.; Ng, Hok K.

    2010-01-01

    This paper describes a class of strategies for reducing persistent contrail formation in the United States airspace. The primary objective is to minimize potential contrail formation regions by altering the aircraft's cruising altitude in a fuel-efficient way. The results show that the contrail formations can be reduced significantly without extra fuel consumption and without adversely affecting congestion in the airspace. The contrail formations can be further reduced by using extra fuel. For the day tested, the maximal reduction strategy has a 53% contrail reduction rate. The most fuel-efficient strategy has an 8% reduction rate with 2.86% less fuel-burnt compared to the maximal reduction strategy. Using a cost function which penalizes extra fuel consumed while maximizing the amount of contrail reduction provides a flexible way to trade off between contrail reduction and fuel consumption. It can achieve a 35% contrail reduction rate with only 0.23% extra fuel consumption. The proposed fuel-efficient contrail reduction strategy provides a solution to reduce aviation-induced environmental impact on a daily basis.

  12. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    SciTech Connect

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-10-10

    In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER.

  13. Faster and cleaner real-time pure shift NMR experiments

    NASA Astrophysics Data System (ADS)

    Mauhart, Johannes; Glanzer, Simon; Sakhaii, Peyman; Bermel, Wolfgang; Zangger, Klaus

    2015-10-01

    Real-time pure shift experiments provide highly resolved proton NMR spectra which do not require any special processing. Although being more sensitive than their pseudo 2D counterparts, their signal intensities per unit time are still far below regular NMR spectra. In addition, scalar coupling evolution during the individual data chunks produces decoupling sidebands. Here we show that faster and cleaner real-time pure shift spectra can be obtained through the implementation of two parameter alterations. Variation of the FID chunk lengths between individual transients significantly suppresses decoupling sidebands for any kind of real-time pure shift spectra and thus allows for example the analysis of minor components in compound mixtures. Shifting the excitation frequency between individual scans of real-time slice-selective pure shift spectra increases their sensitivity obtainable in unit time by allowing faster repetitions of acquisitions.

  14. Analysis of Common Household Cleaner-Disinfectants by Capillary Electrophoresis

    NASA Astrophysics Data System (ADS)

    Gardner, William P.; Girard, James E.

    2000-10-01

    The use of capillary electrophoresis (CE) as an analytical technique in research, industrial, and commercial laboratories is growing rapidly. It is therefore very important to expose undergraduate instrumental analysis students to capillary electrophoresis. In this report we describe the CE analysis for benzalkonium compounds in common household cleaners and disinfectants. The surfactant nature of the benzalkonium compounds is the key consideration in performing the analysis, and modifications to the CE running buffer must be performed in order to successfully analyze the products. This experiment also illustrates the importance of (i) using peak areas corrected for variations in migration time to improve accuracy and (ii) using internal standards to improve the precision of capillary electrophoresis results.

  15. Fundamentals of cleaner technology in the chemicals industry.

    PubMed

    Simmler, W

    1982-10-01

    Basic synthetic processes start with more or less inert material of natural origin, both inorganic and organic matter. Process energy is the agent for converting starting material of low reactivity into highly reactive derivatives or elements. The principles of chemical reactions as first steps of synthesis are explained along with the formation of by-products. The second steps of applying separation techniques for purposes of concentration and purification of products desired and of extracting unwanted and harmful products to be reused or eliminated are presented as critical examples. Reuse of by-products within the limits of chemical recycling, as well as degradation or final waste disposal, are shown as third steps. A concept of cleaner technology is outlined as an unachievable aim due to natural limitations of both entropy and energy. PMID:7169033

  16. New high efficiency mixed cycles with air-blown combustion for CO{sub 2} emission abatement

    SciTech Connect

    Gambini, M.; Guizzi, G.L.; Vellini, M.

    1999-07-01

    In this paper a new advanced mixed cycle (AMC) for CO{sub 2} emission abatement with high conversion efficiency is presented. The AMC plant lay-out consists of a reheat gas turbine with steam injection in the first combustion chamber, a steam turbine for steam expansion before its injection, a heat recovery boiler for superheated and resuperheated steam generation and an atmospheric separator for water recovery from exhaust gas mixture. The steam recirculation in the cycle allows to reduce the excess of air to limit the turbine inlet temperature and then to enrich the exhaust gas by CO{sub 2}, as it occurs in combined cycle provided with exhaust gas recirculation at the compressor inlet. This involves a stack flow rate much lower than in conventional cycle configuration sot that exhaust gas treatment for CO{sub 2} removal may be usefully applied. In this work the chemical absorption technique for CO{sub 2} removal has been considered. The thermodynamic performance of the proposed AMC plant has been investigated in comparison with that attainable by combined cycle power plants (CC). This comparison has been developed pointing out the efficiency decrease involved by the CO{sub 2} removal systems and by the unit for the liquefaction of the removed carbon dioxide. The main result of the performed investigation is that while the two plants attain the same efficiency level without CO{sub 2} removal (about 56% for AMC and 55.8% for CC) the AMC plant achieves a net electric efficiency of about 50% with CO{sub 2} removal and liquefaction units: it's over 2 points higher than the efficiency evaluated for the Cc equipped with the same CO{sub 2} units (about 47.7%). The final carbon dioxide emissions are about 0.04 kg/kWh for AMC and CC, while the emissions of the plants without CO{sub 2} removal systems are about 0.36 kg/kWh.

  17. Evolution and diversification of National Cleaner Production Centres (NCPCs).

    PubMed

    Van Berkel, Rene

    2010-07-01

    Since 1994 UNIDO and UNEP cooperate in a Programme to establish National Cleaner Production Centres (NCPCs) as a mechanism for delivery of Cleaner Production (CP) services to businesses, governments and other organisations. In 2007, 38 NCPCs were operational in 37 developing and transition countries. While initially set up in near-identical ways in each country, over time NCPCs evolved in response to both programme-internal and country-level factors. The resulting diversity among NCPCs is described and analysed here. Differentiation and specialisation had occurred in service areas or topics both within and between NCPCs, however without a clear strategy for integration and synergy. NCPCs were becoming part of expanding networks of business services providers nationally forcing some to focus on audit and training services (tier 1), and others on specialist services in CP technology and/or policy (tier 2) and/or networking services (tier 3). All NCPCs were on a trajectory from a project management organisation to a nationally-owned entity. The different management requirements were not proactively managed and technical aspects of CP service delivery overshadowed institutional and governance aspects of establishing and operating the NCPC institution. Differences in service delivery methods between NCPCs are most evident in three service areas: CP assessments; policy advice; and transfer of Environmentally Sound Technologies. It is argued here that understanding root causes and benefits of this presently-observed differentiation, could lay the foundation for capturing and advancing best practice CP concepts, methods and policies. This in turn would enable strategic planning for customised interventions and support at the national level.

  18. Air motion sensing hairs of arthropods detect high frequencies at near-maximal mechanical efficiency

    PubMed Central

    Bathellier, Brice; Steinmann, Thomas; Barth, Friedrich G.; Casas, Jérôme

    2012-01-01

    Using measurements based on particle image velocimetry in combination with a novel compact theoretical framework to describe hair mechanics, we found that spider and cricket air motion sensing hairs work close to the physical limit of sensitivity and energy transmission in a broad range of relatively high frequencies. In this range, the hairs closely follow the motion of the incoming flow because a minimum of energy is dissipated by forces acting in their basal articulation. This frequency band is located beyond the frequency at which the angular displacement of the hair is maximum which is between about 40 and 600 Hz, depending on hair length (Barth et al. [1] Phil. Trans. R. Soc. Lond. B 340, 445–461 (doi:10.1098/rstb.1993.0084)). Given that the magnitude of natural airborne signals is known to decrease with frequency, our results point towards the possible existence of spectral signatures in the higher frequency range that may be weak but of biological significance. PMID:22171067

  19. Cleaner shrimp use a rocking dance to advertise cleaning service to clients.

    PubMed

    Becker, Justine H A; Curtis, Lynda M; Grutter, Alexandra S

    2005-04-26

    Signals transmit information to receivers about sender attributes, increase the fitness of both parties, and are selected for in cooperative interactions between species to reduce conflict [1, 2]. Marine cleaning interactions are known for stereotyped behaviors [3-6] that likely serve as signals. For example, "dancing" and "tactile dancing" in cleaner fish may serve to advertise cleaning services to client fish [7] and manipulate client behavior [8], respectively. Cleaner shrimp clean fish [9], yet are cryptic in comparison to cleaner fish. Signals, therefore, are likely essential for cleaner shrimp to attract clients. Here, we show that the yellow-beaked cleaner shrimp [10] Urocaridella sp. c [11] uses a stereotypical side-to-side movement, or "rocking dance," while approaching potential client fish in the water column. This dance was followed by a cleaning interaction with the client 100% of the time. Hungry cleaner shrimp, which are more willing to clean than satiated ones [12], spent more time rocking and in closer proximity to clients Cephalopholis cyanostigma than satiated ones, and when given a choice, clients preferred hungry, rocking shrimp. The rocking dance therefore influenced client behavior and, thus, appears to function as a signal to advertise the presence of cleaner shrimp to potential clients. PMID:15854910

  20. Highly efficient indoor air purification using adsorption-enhanced-photocatalysis-based microporous TiO2 at short residence time.

    PubMed

    Lv, Jinze; Zhu, Lizhong

    2013-01-01

    A short residence time is a key design parameter for the removal of organic pollutants in catalyst-based indoor air purification systems. In this study, we synthesized a series of TiO2 with different micropore volumes and studied their removal efficiency of indoor carbonyl pollutants at a short residence time. Our results indicated that the superior adsorption capability of TiO2 with micropores improved its performance in the photocatalytic degradation of cyclohexanone, while the photocatalytic removal of the pollutant successfully kept porous TiO2 from becoming saturated. When treated with 1 mg m(-3) cyclohexanone at a relatively humidity of 18%, the adsorption amount on microporous TiO2 was 5.4-7.9 times higher than that on P25. Removal efficiency via photocatalysis followed'the same order as the adsorption amount: TiO2-5 > TiO2-20 > TiO2-60 > TiO2-180 > P25. The advantage of microporous TiO2 over P25 became more pronounced when the residence time declined from 0.072 to 0.036 s. Moreover, as the concentration of cyclohexanone deceased from 1000 ppb to 500 ppb, removal efficiency by microporous TiO2 increased more rapidly than P25.

  1. Will cheap gas and efficient cars imperil air-quality goals under relaxed emission standards

    SciTech Connect

    LaBelle, S.J.; Saricks, C.L.; Moses, D.O.

    1983-04-01

    Long-term trends, to the year 2000, of urban household travel were forecast for prototype metropolitan areas under several sets of energy prices, auto fuel economy, and emission standards. Dramatic improvements in air quality were forecast due to redistribution of travel and lowered emissions. The exception to this trend to rapidly growing cities, such as those in the west and southwest experiencing sprawl development that characterized many urbanized areas in the industrial northeast and midwest during the 1950's and 1960's. In one test city, where the rate of urbanization has slowed significantly, analysis indicated that relaxation of the light-duty-vehicle NO/sub x/ standard from 1.0 gm/mi to 2.0 gm/mi would not severely threaten attainment of the ambient NO/sub x/ standards by 1987 owing to redistribution of population and activities. The difference in total energy impacts was determined to be negligible, assuming moderate increase in petroleum prices through 1995 (3.1%/year). In another policy test, without changing emission standards, an increase in fuel price of 3.75%/year from 1980 to 2000 reduced travel and provided a 4% decrease in energy use and a corresponding decrease in CO, HC and NO/sub x/. Virtually all of the reduction in travel and emissions was due to non-work travel, which fell 9%. The price increase damped the increase in auto travel per person that would occur as autos become cheaper to operate and as household wealth increases, making the answer to the title a cautious yes, given steady or slowly rising fuel prices.

  2. Efficiency of clay-TiO2 nanocomposites on the photocatalytic eliminationof a model hydrophobic air pollutant

    SciTech Connect

    Kibanova, Daria; Cervini-Silva, Javiera; Destaillats, Hugo

    2009-01-01

    Clay-supported TiO2 photocatalysts can potentially improve the performance of air treatment technologies via enhanced adsorption and reactivity of target volatile organic compounds (VOCs). In this study, a bench-top photocatalytic flow reactor was used to evaluate the efficiency of hectorite-TiO2 and kaolinite-TiO2, two novel composite materials synthesized in our laboratory. Toluene, a model hydrophobic VOC and a common indoor air pollutant, was introduced in the air stream at realistic concentrations, and reacted under UVA (gamma max = 365 nm) or UVC (gamma max = 254 nm) irradiation. The UVC lamp generated secondary emission at 185 nm, leading to the formation of ozone and other short-lived reactive species. Performance of clay-TiO2 composites was compared with that of pure TiO2 (Degussa P25), and with UV irradiation in the absence of photocatalyst under identical conditions. Films of clay-TiO2 composites and of P25 were prepared by a dip-coating method on the surface of Raschig rings, which were placed inside the flow reactor. An upstream toluene concentration of ~;;170 ppbv was generated by diluting a constant flow of toluene vapor from a diffusion source with dry air, or with humid air at 10, 33 and 66percent relative humidity (RH). Toluene concentrations were determined by collecting Tenax-TA (R) sorbent tubes downstream of the reactor, with subsequent thermal desorption -- GC/MS analysis. The fraction of toluene removed, percentR, and the reaction rate, Tr, were calculated for each experimental condition from the concentration changes measured with and without UV irradiation. Use of UVC light (UV/TiO2/O3) led to overall higher reactivity, which can be partially attributed to the contribution of gas phase reactions by short-lived radical species. When the reaction rate was normalized to the light irradiance, Tr/I gamma, the UV/TiO2 reaction under UVA irradiation was more efficient for samples with a higher content of TiO2 (P25 and Hecto-TiO2), but not for Kao

  3. Experimental und numerical investigations on cooling efficiency of Air-Mist nozzles on steel during continuous casting

    NASA Astrophysics Data System (ADS)

    Arth, G.; Taferner, M.; Bernhard, C.; Michelic, S.

    2016-07-01

    Cooling strategies in continuous casting of steel can vary from rapid cooling to slow cooling, mainly controlled by adjusting the amount of water sprayed onto the surface of the product. Inadequate adjustment however can lead to local surface undercooling or reheating, leading to surface and inner defects. This paper focuses on cooling efficiency of Air-Mist nozzles on casted steel and the experimental and numerical prediction of surface temperature distributions over the product width. The first part explains the determination of heat transfer coefficients (HTC) on laboratory scale, using a so called nozzle measuring stand (NMS). Based on measured water distributions and determined HTC's for air-mist nozzles using the NMS, surface temperatures are calculated by a transient 2D-model on a simple steel plate, explained in the second part of this paper. Simulations are carried out varying water impact density and spray water distribution, consequently influencing the local HTC distribution over the plate width. Furthermore, these results will be interpreted with regard to their consequence for surface and internal quality of the cast product. The results reveal the difficulty of correct adjustment of the amount of sprayed water, concurrent influencing water distribution and thus changing HTC distribution and surface temperature.

  4. Change in NO2 reveals Parade Blue is cleaner than APEC Blue

    NASA Astrophysics Data System (ADS)

    Liu, Haoran; Liu, Cheng; Xie, Zhouqing; Xie, Pinhua; Xing, Chengzhi; Xu, Jin; Liu, Jianguo

    2016-04-01

    The spectacular Parade Blue (blue sky), and APEC Blue (blue sky) were renowned worldwide caused by the limiting discharge policy of the Chinese government. For evaluating the reduction of these two events, we analyzed the variation of NO2 columns Beijing by looking at a long-term monitoring using Multi-Axis Differential Optical Absorption Spectroscopy (MAX-DOAS) and the Ozone Monitoring Instrument (OMI) satellite observations from August 2014 to November 2015, covering Grand Military Parade (GMP, September 2015) and APEC (November 2014) period. We found that the NO2 columns abruptly decreased both GMP and APEC. However, change in the MAX-DOAS and the OMI NO2 during GMP was larger than during APEC via comparison with the same period in 2014, indicating Parade Blue is cleaner than APEC Blue. The spatial distribution of NO2 and backward trajectories together with meterological parameters suggested that GMP Blue may be due to the regional significant decreasing discharge in peripheral cities. No weekend effect during GMP further confirmed the role of controlling discharge. This study provides direct evidence that it is possible to clean air in China.

  5. Adult Cleaner Wrasse Outperform Capuchin Monkeys, Chimpanzees and Orang-utans in a Complex Foraging Task Derived from Cleaner – Client Reef Fish Cooperation

    PubMed Central

    Proctor, Darby; Essler, Jennifer; Pinto, Ana I.; Wismer, Sharon; Stoinski, Tara; Brosnan, Sarah F.; Bshary, Redouan

    2012-01-01

    The insight that animals' cognitive abilities are linked to their evolutionary history, and hence their ecology, provides the framework for the comparative approach. Despite primates renowned dietary complexity and social cognition, including cooperative abilities, we here demonstrate that cleaner wrasse outperform three primate species, capuchin monkeys, chimpanzees and orang-utans, in a foraging task involving a choice between two actions, both of which yield identical immediate rewards, but only one of which yields an additional delayed reward. The foraging task decisions involve partner choice in cleaners: they must service visiting client reef fish before resident clients to access both; otherwise the former switch to a different cleaner. Wild caught adult, but not juvenile, cleaners learned to solve the task quickly and relearned the task when it was reversed. The majority of primates failed to perform above chance after 100 trials, which is in sharp contrast to previous studies showing that primates easily learn to choose an action that yields immediate double rewards compared to an alternative action. In conclusion, the adult cleaners' ability to choose a superior action with initially neutral consequences is likely due to repeated exposure in nature, which leads to specific learned optimal foraging decision rules. PMID:23185293

  6. Mobile Source Air Toxics (MSATs) from High Efficiency Clean Combustion: Catalytic Exhaust Treatment Effects

    SciTech Connect

    Storey, John Morse; Lewis Sr, Samuel Arthur; Parks, II, James E; Barone, Teresa L; Prikhodko, Vitaly Y

    2008-01-01

    High Efficiency Clean Combustion (HECC) strategies such as homogenous charge compression ignition (HCCI) and pre-mixed charge compression ignition (PCCI) offer much promise for the reduction of NOx and PM from diesel engines. While delivering low PM and low NOx, these combustion modes often produce much higher levels of CO and HC than conventional diesel combustion modes. In addition, partially oxygenated species such as formaldehyde (an MSAT) and other aldehydes increase with HECC modes. The higher levels of CO and HCs have the potential to compromise the performance of the catalytic aftertreatment, specifically at low load operating points. As HECC strategies become incorporated into vehicle calibrations, manufacturers need to avoid producing MSATs in higher quantities than found in conventional combustion modes. This paper describes research on two different HECC strategies, HCCI and PCCI. Engine-out data for several MSAT species (formaldehyde, acetaldehyde, benzene, toluene, ethylbenzene, xylenes, naphthalene, PAHs, diesel PM) as well as other HC species are presented and compared when possible with conventional operation. In addition, catalyst-out values were measured to assess the destruction of individual MSATs over the catalyst. At low engine loads, MSATs were higher and catalyst performance was poorer. Particle sizing results identify large differences between PM from conventional and HECC operation.

  7. Using elastin protein to develop highly efficient air cathodes for lithium-O2 batteries

    NASA Astrophysics Data System (ADS)

    Guo, Guilue; Yao, Xin; Ang, Huixiang; Tan, Huiteng; Zhang, Yu; Guo, Yuanyuan; Fong, Eileen; Yan, Qingyu

    2016-01-01

    Transition metal-nitrogen/carbon (M-N/C, M = Fe, Co) catalysts are synthesized using environmentally friendly histidine-tag-rich elastin protein beads, metal sulfate and water soluble carbon nanotubes followed by post-annealing and acid leaching processes. The obtained catalysts are used as cathode materials in lithium-O2 batteries. It has been discovered that during discharge, Li2O2 nanoparticles first nucleate and grow around the bead-decorated CNT regions (M-N/C centres) and coat on the catalysts at a high degree of discharge. The Fe-N/C catalyst-based cathodes deliver a capacity of 12 441 mAh g-1 at a current density of 100 mA g-1. When they were cycled at a limited capacity of 800 mAh g-1 at current densities of 200 or 400 mA g-1, these cathodes showed stable charge voltages of ˜3.65 or 3.90 V, corresponding to energy efficiencies of ˜71.2 or 65.1%, respectively. These results are considerably superior to those of the cathodes based on bare annealed CNTs, which prove that the Fe-N/C catalysts developed here are promising for use in non-aqueous lithium-O2 battery cathodes.

  8. Efficient salt removal in a continuously operated upflow microbial desalination cell with an air cathode.

    PubMed

    Jacobson, Kyle S; Drew, David M; He, Zhen

    2011-01-01

    Microbial desalination cells (MDCs) hold great promise for drinking water production because of potential energy savings during the desalination process. In this study, we developed a continuously operated MDC--upflow microbial desalination cell (UMDC) for the purpose of salt removal. During the 4-month operation, the UMDC constantly removed salts and generated bio-electricity. At a hydraulic retention time (HRT) of 4 days (salt solution) and current production of ∼62 mA, the UMDC was able to remove more than 99% of NaCl from the salt solution that had an initial salt concentration of 30 g total dissolved solids (TDS)/L. In addition, the TDS removal rate was 7.50 g TDSL(-1)d(-1) (salt solution volume) or 5.25 g TDSL(-1)d(-1) (wastewater volume), and the desalinated water met the drinking water standard, in terms of TDS concentration. A high charge transfer efficiency of 98.6% or 81% was achieved at HRT 1 or 4d. The UMDC produced a maximum power density of 30.8 W/m(3). The phenomena of bipolar electrodialysis and proton transport in the UMDC were discussed. These results demonstrated the potential of the UMDC as either a sole desalination process or a pre-desalination reactor for downstream desalination processes.

  9. Using elastin protein to develop highly efficient air cathodes for lithium-O2 batteries.

    PubMed

    Guo, Guilue; Yao, Xin; Ang, Huixiang; Tan, Huiteng; Zhang, Yu; Guo, Yuanyuan; Fong, Eileen; Yan, Qingyu

    2016-01-29

    Transition metal-nitrogen/carbon (M-N/C, M = Fe, Co) catalysts are synthesized using environmentally friendly histidine-tag-rich elastin protein beads, metal sulfate and water soluble carbon nanotubes followed by post-annealing and acid leaching processes. The obtained catalysts are used as cathode materials in lithium-O2 batteries. It has been discovered that during discharge, Li2O2 nanoparticles first nucleate and grow around the bead-decorated CNT regions (M-N/C centres) and coat on the catalysts at a high degree of discharge. The Fe-N/C catalyst-based cathodes deliver a capacity of 12,441 mAh g(-1) at a current density of 100 mA g(-1). When they were cycled at a limited capacity of 800 mAh g(-1) at current densities of 200 or 400 mA g(-1), these cathodes showed stable charge voltages of ∼3.65 or 3.90 V, corresponding to energy efficiencies of ∼71.2 or 65.1%, respectively. These results are considerably superior to those of the cathodes based on bare annealed CNTs, which prove that the Fe-N/C catalysts developed here are promising for use in non-aqueous lithium-O2 battery cathodes.

  10. Rotor hover performance and system design of an efficient coaxial rotary wing micro air vehicle

    NASA Astrophysics Data System (ADS)

    Bohorquez, Felipe

    2007-12-01

    Rotary-wing Micro air vehicles (MAVs) due to their unique hovering and low-speed flight capabilities are specially suited for missions that require operation in constrained spaces. Size restrictions force MAVs to operate in a low Reynolds number aerodynamic regime where viscous effects are dominant. This results in poor aerodynamic performance of conventional airfoils and rotor configurations. This dissertation explores the design issues that affect the hover performance of small-scale rotors and the implementation of a working coaxial MAV prototype. A computerized hover test stand was used for the systematic testing of single and coaxial small-scale rotors. Thin circular arcs were chosen for blade manufacturing because of their good aerodynamic characteristics at low Reynolds numbers, and simplified parameterization. Influence of airfoil geometry on single rotor hover performance was studied on untwisted rectangular blades. Non rectangular blades were used to study coupled airfoil and blade parameters. Tip tapered geometries were manufactured by removing material from baseline rectangular blades producing a coupling between blade planform, twist distribution, and spanwise airfoil shape. Performance gains were obtained by introducing large negative twist angles over short radial distances at the blade tips. A parametric study of the blade geometries resulted in maximum figures of merit of 0.65. Coaxial rotor performance at torque equilibrium was explored for different trims and operating conditions. It was found that the upper rotor was marginally affected by the lower one at spacings larger than 35% of the rotor radius, and that it produced about 60% of the total thrust. Experiments showed that power loading was maximized when higher collectives were used at the lower rotor, resulting in sizable differences in rotational speed between rotors. The CFD solver INS2d was used for a two-dimensional parametric aerodynamic study of circular arc airfoils. Lift, drag, and

  11. Ultra High Efficiency ESP for Fine Particulate and Air Toxics Control

    SciTech Connect

    Srinivasachar, Srivats; Pease, Benjamin R.; Porle, Kjell; Mauritzson, Christer; Haythornthwaite, Sheila

    1997-07-01

    Nearly ninety percent of U.S. coal-fired utility boilers are equipped with electrostatic precipitators (ESP). Cost effective retrofittable ESP technologies are the only means to accomplish Department of Energy's (DOE) goal of a major reduction in fine particulate and air toxic emissions from coal-fired power plants. Particles in the size range of 0.1 to 5 {micro}m typically escape ESPs. Metals, such as arsenic, cadmium, lead, molybdenum and antimony, concentrate on these particles. This is the main driver for improved fine particulate control. Vapor phase emissions of mercury, selenium and arsenic are also of major concern. Current dry ESPs, which operate at temperatures greater than 280 F, provide little control for vapor phase toxics. The need for inherent improvement to ESPs has to be considered keeping in perspective the current trend towards the use of low sulfur coals. Switching to low sulfur coals is the dominant approach for SO{sub 2} emission reduction in the utility industry. Low sulfur coals generate high resistivity ash, which can cause an undesirable phenomenon called ''back corona.'' Higher particulate emissions occur if there is back corona in the ESP. Results of the pilot-scale testing identified the ''low temperature ESP'' concept to have the biggest impact for the two low sulfur coals investigated. Lowering the flue gas temperature to 220 F provided the maximum impact in terms of decreased emissions. Intermediate operating temperatures (reduction from 340 to 270 F) also gave significant ESP performance improvement. A significant reduction in particulate emissions was also noted when the flue gas humidity was increased (temperature held constant) from the baseline condition for these moderately high resistivity ash coals. Independent control of flue gas humidity and temperature was an important and a notable element in this project. Mercury emissions were also measured as a function of flue gas temperature. Mercury emissions decreased as the flue

  12. Energy cost of speec skating and efficiency of work against air resistance.

    PubMed

    Di Prampero, P E; Cortili, G; Mognoni, P; Saibene, F

    1976-04-01

    The energy expenditure during speed ice skating (PB=650 mmHg; T=-5 degrees C) was measured on 13 athletes (speed range: 4-12 m/s) from VO2 and (for speeds greater than 10 m/s) from blood lactic acid concentration. The energy spent (O2 equivalents) per unit body wt and unit distance (Etot/V, ml/kg-min) increases with the speed (v, m/s): Etot/v=0.049 + 0.44 X 10(-3) V2. At 10 m/s, Vtot/v amounts then to 0.093 ml/kg-m: about half the value of running. The constant 0.049 ml/kg-m is interpreted as the energy spent against gravitational and inertial forces. The term 0.44 X 10(-3) v2 indicates the energy spent against the wind, the constant 0.44 X 10(-3) ml-s2-kg-1-m-3 being a measure of k/e, where k is the coefficient relating drag to v2, and e the efficiency of work against the wind. From a direct estimate of k in a wind tunnel, e was calculated as 0.11. In running, skating, and cycling k/e is similar (approximately 0.020 ml-s2-m-3 per m2 body area), hence at a given speed the energy spent against the wind is equal. On the contrary, the energy spent against other forces decreases in the above order: 0.19, 0.05, 0.018 ml-m-1 per kg body wt. This explains the different speeds attained in these exercises with the same power output.

  13. Experimental method to reveal the effect of rotor magnet size and air gap on artificial heart driving motor torque and efficiency.

    PubMed

    Qian, K X; Yuan, H Y; Ru, W M; Zeng, P

    2002-01-01

    To investigate experimentally the effect of rotor magnet design on artificial heart driving motor performance, seven rotors with different magnet lengths or thicknesses, as well as different peripheral angles, were manufactured and tested in the same motor stator with different rotating speeds. The input power (voltage and current) and output torque were measured and the motor efficiency was computed. The results demonstrated that the reduction of rotor magnet size and the enlargement of the air gap between the rotor magnets and the stator coil core have no significant effect on motor efficiency, but will reduce the torque value on which the motor achieves the highest efficiency; it could be remedied however by increasing the rotating speed, because the torque at the high efficiency point will increase along with the rotating speed. These results may provide a basis for developing small rotor magnets, large air gap and high efficiency motors for driving an artificial heart pump.

  14. On the air cleansing efficiency of an extended green wall: a CFD analysis of mechanistic details of transport processes.

    PubMed

    Joshi, Saumitra V; Ghosh, Sat

    2014-11-21

    The detrimental impact of rising air pollution levels in urban landscapes has become conspicuous over the last decade, particularly in developing countries. This novel numerical study quantifies the cleansing efficiency of green façades draped with a copiously growing tropical creeper Vernonia elaeagnifolia. Turbulent transport of SO2 to the leaf boundary layer and subsequent diffusion across stomatal pores into the mesophyllic cells is modeled at the micro level, including its ionic dissociation in the leaf׳s interior. A SEM analysis indicates stomatal dimensions and density. Whilst previous studies have used either spatially averaged equations or resistance models, a spatially discretized computational approach is adopted in this study. The resulting concentration distribution is used to calculate the deposition velocity on stomatal pores, which is then extrapolated over the entire façade to yield bulk pollutant removal rates. A deposition velocity of 1.53mms(-1) and 0.72mms(-1) is obtained for open and closed pores respectively, with removal rates equal to 1.11×10(-6)s(-1) and 1.05×10(-6)s(-1) for dry and humid weather respectively. Sensitivity studies on the removal rate are carried out based on humidity, stomatal aperture and leaf temperature. The removal rate dependence on the Leaf Area Index (LAI) is also investigated. It is inferred from simulations that vegetated façades are efficient at mitigation of residual pollution. PMID:25084039

  15. Adhesion Performance of Solid Film Lubricants on Substrates Cleaned With Environmentally Compliant Cleaners

    NASA Technical Reports Server (NTRS)

    Hall, P. B.; Thom, R. L.

    1997-01-01

    Solid film adhesion testing was used to determine the effect different environmentally compliant cleaners have on the adhesion properties of solid film lubricants used for several NASA programs. In an action to remove ozone depleting chemicals from aerospace processes, a replacement cleaner must be identified that does not affect the adhesion of solid film lubricants used on flight critical NASA hardware. ASTM D251083 Standard Test Method for Adhesion of Solid Film Lubricants was used to evaluate the cleaners. Two different lubricants - Inlox 88 and Boosterlube - were tested using various commercially available cleaners. Inlox 88 is produced by E/M Corporation and is a liquid oxygen compatible lubricant used in the Space Shuttle Main Engine, and Boosterlube is a new lubricant being implemented for use on the Space Shuttle Solid Rocket Booster. These lubricants were selected because of their specific use on flight critical NASA components. Results of this testing are presented in the paper.

  16. ASSESSMENT OF STACHYBOTRYS REGROWTH ON CONTAMINATED WALLBOARD AFTER TREATMENT WITH COMMON SURFACE CLEANERS/DISINFECTANTS

    EPA Science Inventory

    The paper describes results of experiments assessing the efficacy of treating mold-contaminated gypsum wallboard with cleaners and/or disinfectants. Although the accepted recommendations for handling Stachybotrys chartarum contaminated gypsum wallboard are removal and replacement...

  17. 75 FR 146 - Proposed Cercla Administrative Cost Recovery Settlement; David Benvenuti and Howe Cleaners, Howe...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-04

    ... given of a proposed administrative settlement for recovery of past costs concerning the Howe Cleaners... withdraw its consent to the settlement if comments received disclose facts or considerations which...

  18. IMPACT OF COSOLVENT FLUSHING ON SUBSURFACE MICROBIAL ECOLOGY AT THE FORMER SAGE'S DRY CLEANER SITE

    EPA Science Inventory

    The Solvent Extraction Residual Biotreatment (SERB) technology was evaluated at the former Sage's Dry Cleaner site in Jacksonville, FL where an area of tetrachloroethylene (PCE) contamination was identified. The SERB technology is a treatment train approach to complete site rest...

  19. IMPACT OF COSOLVENT FLUSHING ON SUBSURFACE MICROBIAL ECOLOGY AT A FORMER DRY CLEANER SITE

    EPA Science Inventory

    The Solvent Extraction Residual Biotreatment (SERB) technology was evaluated at a former dry cleaner site in Jacksonville, FL where an area of tetrachloroethene (PCE) contamination was identified. The SERB technology is a treatment train approach to complete site restoration, wh...

  20. Spectral sensitivity, spatial resolution and temporal resolution and their implications for conspecific signalling in cleaner shrimp.

    PubMed

    Caves, Eleanor M; Frank, Tamara M; Johnsen, Sönke

    2016-02-01

    Cleaner shrimp (Decapoda) regularly interact with conspecifics and client reef fish, both of which appear colourful and finely patterned to human observers. However, whether cleaner shrimp can perceive the colour patterns of conspecifics and clients is unknown, because cleaner shrimp visual capabilities are unstudied. We quantified spectral sensitivity and temporal resolution using electroretinography (ERG), and spatial resolution using both morphological (inter-ommatidial angle) and behavioural (optomotor) methods in three cleaner shrimp species: Lysmata amboinensis, Ancylomenes pedersoni and Urocaridella antonbruunii. In all three species, we found strong evidence for only a single spectral sensitivity peak of (mean ± s.e.m.) 518 ± 5, 518 ± 2 and 533 ± 3 nm, respectively. Temporal resolution in dark-adapted eyes was 39 ± 1.3, 36 ± 0.6 and 34 ± 1.3 Hz. Spatial resolution was 9.9 ± 0.3, 8.3 ± 0.1 and 11 ± 0.5 deg, respectively, which is low compared with other compound eyes of similar size. Assuming monochromacy, we present approximations of cleaner shrimp perception of both conspecifics and clients, and show that cleaner shrimp visual capabilities are sufficient to detect the outlines of large stimuli, but not to detect the colour patterns of conspecifics or clients, even over short distances. Thus, conspecific viewers have probably not played a role in the evolution of cleaner shrimp appearance; rather, further studies should investigate whether cleaner shrimp colour patterns have evolved to be viewed by client reef fish, many of which possess tri- and tetra-chromatic colour vision and relatively high spatial acuity.

  1. Biological monitoring of exposure to benzene in petrol pump workers and dry cleaners.

    PubMed

    Verma, Y; Rana, S V

    2001-10-01

    Exposure to benzene has been monitored in petrol-pump workers and dry cleaners of Meerut City (India) by measuring phenol content of their urine samples. Average values for phenol in urine were higher in petrol-pump workers than dry cleaners. Alcoholic subjects excreted more phenol than smokers and non-vegetarians. It is concluded that alcohol can alter the susceptibility of man to benzene toxicity by affecting its metabolism.

  2. Spectral sensitivity, spatial resolution and temporal resolution and their implications for conspecific signalling in cleaner shrimp.

    PubMed

    Caves, Eleanor M; Frank, Tamara M; Johnsen, Sönke

    2016-02-01

    Cleaner shrimp (Decapoda) regularly interact with conspecifics and client reef fish, both of which appear colourful and finely patterned to human observers. However, whether cleaner shrimp can perceive the colour patterns of conspecifics and clients is unknown, because cleaner shrimp visual capabilities are unstudied. We quantified spectral sensitivity and temporal resolution using electroretinography (ERG), and spatial resolution using both morphological (inter-ommatidial angle) and behavioural (optomotor) methods in three cleaner shrimp species: Lysmata amboinensis, Ancylomenes pedersoni and Urocaridella antonbruunii. In all three species, we found strong evidence for only a single spectral sensitivity peak of (mean ± s.e.m.) 518 ± 5, 518 ± 2 and 533 ± 3 nm, respectively. Temporal resolution in dark-adapted eyes was 39 ± 1.3, 36 ± 0.6 and 34 ± 1.3 Hz. Spatial resolution was 9.9 ± 0.3, 8.3 ± 0.1 and 11 ± 0.5 deg, respectively, which is low compared with other compound eyes of similar size. Assuming monochromacy, we present approximations of cleaner shrimp perception of both conspecifics and clients, and show that cleaner shrimp visual capabilities are sufficient to detect the outlines of large stimuli, but not to detect the colour patterns of conspecifics or clients, even over short distances. Thus, conspecific viewers have probably not played a role in the evolution of cleaner shrimp appearance; rather, further studies should investigate whether cleaner shrimp colour patterns have evolved to be viewed by client reef fish, many of which possess tri- and tetra-chromatic colour vision and relatively high spatial acuity. PMID:26747903

  3. Future Air Conditioning Energy Consumption in Developing Countriesand what can be done about it: The Potential of Efficiency in theResidential Sector

    SciTech Connect

    McNeil, Michael A.; Letschert, Virginie E.

    2007-05-01

    The dynamics of air conditioning are of particular interestto energy analysts, both because of the high energy consumption of thisproduct, but also its disproportionate impact on peak load. This paperaddresses the special role of this end use as a driver of residentialelectricity consumption in rapidly developing economies. Recent historyhas shown that air conditioner ownership can grow grows more rapidly thaneconomic growth in warm-climate countries. In 1990, less than a percentof urban Chinese households owned an air conditioner; by 2003 this numberrose to 62 percent. The evidence suggests a similar explosion of airconditioner use in many other countries is not far behind. Room airconditioner purchases in India are currently growing at 20 percent peryear, with about half of these purchases attributed to the residentialsector. This paper draws on two distinct methodological elements toassess future residential air conditioner 'business as usual' electricityconsumption by country/region and to consider specific alternative 'highefficiency' scenarios. The first component is an econometric ownershipand use model based on household income, climate and demographicparameters. The second combines ownership forecasts and stock accountingwith geographically specific efficiency scenarios within a uniqueanalysis framework (BUENAS) developed by LBNL. The efficiency scenariomodule considers current efficiency baselines, available technologies,and achievable timelines for development of market transformationprograms, such as minimum efficiency performance standards (MEPS) andlabeling programs. The result is a detailed set of consumption andemissions scenarios for residential air conditioning.

  4. Arginine vasotocin reduces levels of cooperative behaviour in a cleaner fish.

    PubMed

    Cardoso, Sónia C; Paitio, José R; Oliveira, Rui F; Bshary, Redouan; Soares, Marta C

    2015-02-01

    Cooperation between unrelated individuals usually involves investments that often mean a decrease in immediate payoffs, but ensure future benefits. Here we investigated the potential role of the neuropeptides Arginine-vasotocin (AVT) and Isotocin (IT) as proximate agents affecting individuals' cooperative levels in the Indo-pacific bluestreak cleaner wrasse Labroides dimidiatus. Their 'client' reef fish partners only benefit from interacting if cleaners eat ectoparasites and refrain from gleaning preferred client mucus. Thus, cleaners must control their impulse to eat according to their preference, and eat less preferred items to maintain ongoing interactions and avoid clients' leaving or punishing. We found that solely the experimental transient higher dosage of AVT led to a decrease of cleaners' willingness to feed against their preference, while IT and AVT antagonists had no significant effects. The sole effect of AVT on cleaner's performance may imply a link between AVT's influence and a potential activation of a stress response. Our results confirm the importance of the AVT/AVP system as an agent affecting levels of cooperation, offering a potential mechanistic pathway for the reported flexible service quality that cleaners provide their clients. PMID:25449412

  5. Forebrain neuropeptide regulation of pair association and behavior in cooperating cleaner fish.

    PubMed

    Cardoso, Sónia C; Grutter, Alexandra S; Paula, José R; André, Gonçalo I; Messias, João P; Gozdowska, Magdalena; Kulczykowska, Ewa; Soares, Marta C

    2015-06-01

    Animals establish privileged relationships with specific partners, which are treated differently from other conspecifics, and contribute to behavioral variation. However, there is limited information on the underlying physiological mechanisms involved in the establishment of these privileged ties and their relationship to individual cooperation levels. The Indo-Pacific bluestreak cleaner wrasse Labroides dimidiatus often forages in mixed-sex pairs when cleaning fish clients. Intra-couple conflicts often arise during a joint client inspection, which may alter the overall quality of cleaning service provided. Here we tested two hypotheses: a) whether intra-pair association (i.e. association index), measured with joint interspecific cleaning and intraspecific behavior, is correlated with neuroendocrine mechanisms involving forebrain neuropeptides arginine vasotocin (AVT) and isotocin (IT) and b) whether these neuropeptide level shifts relate to an individual's interspecific service quality. We found that partner support (number of cleaning interactions and tactile stimulation) received by male cleaners increased with association index. When cleaners inspected clients alone, cleaners' cheating decreased with association index for females but not males. AVT levels did not differ according to sex or association level. Forebrain IT levels increased with association index for males, whereas no relationship was found for females. Finally, cleaner cheating varied between sex and forebrain IT levels. Findings indicate that variation in pairs' relationships influences male and female cleaner fish differently and contributes to the variation of brain neuropeptide levels, which is linked to distinct cooperative outcomes. PMID:25802022

  6. Forebrain neuropeptide regulation of pair association and behavior in cooperating cleaner fish.

    PubMed

    Cardoso, Sónia C; Grutter, Alexandra S; Paula, José R; André, Gonçalo I; Messias, João P; Gozdowska, Magdalena; Kulczykowska, Ewa; Soares, Marta C

    2015-06-01

    Animals establish privileged relationships with specific partners, which are treated differently from other conspecifics, and contribute to behavioral variation. However, there is limited information on the underlying physiological mechanisms involved in the establishment of these privileged ties and their relationship to individual cooperation levels. The Indo-Pacific bluestreak cleaner wrasse Labroides dimidiatus often forages in mixed-sex pairs when cleaning fish clients. Intra-couple conflicts often arise during a joint client inspection, which may alter the overall quality of cleaning service provided. Here we tested two hypotheses: a) whether intra-pair association (i.e. association index), measured with joint interspecific cleaning and intraspecific behavior, is correlated with neuroendocrine mechanisms involving forebrain neuropeptides arginine vasotocin (AVT) and isotocin (IT) and b) whether these neuropeptide level shifts relate to an individual's interspecific service quality. We found that partner support (number of cleaning interactions and tactile stimulation) received by male cleaners increased with association index. When cleaners inspected clients alone, cleaners' cheating decreased with association index for females but not males. AVT levels did not differ according to sex or association level. Forebrain IT levels increased with association index for males, whereas no relationship was found for females. Finally, cleaner cheating varied between sex and forebrain IT levels. Findings indicate that variation in pairs' relationships influences male and female cleaner fish differently and contributes to the variation of brain neuropeptide levels, which is linked to distinct cooperative outcomes.

  7. Improving the energy efficiency of refrigeration plants by decreasing the temperature difference in air-cooled condensers

    NASA Astrophysics Data System (ADS)

    Shishov, V. V.; Talyzin, M. S.

    2015-09-01

    The electric energy consumption efficiency is estimated in comparing the real refrigeration machine cycle with the theoretical inverse Carnot cycle. The potential for saving electricity in using aircooled condensers with different values of temperature difference is shown. A procedure for calculating a refrigerating system with the evaporation temperature equal to -10°C, which corresponds at this temperature level to the thermal load of a standard supermarket, is described. The calculation was carried out taking into account the annual profile of temperatures in the indicated locality and based on the possibility of adjusting the condenser capacity for maintaining constant condensation temperature. The payback period in case of using condensers with different values of temperature difference is calculated; for example, in using condensers with a temperature difference of less than 15 K, the payback period will be less than one year. Decreasing the temperature difference results, on one hand, in a larger annual consumption of electric energy by the condenser fans, and on the other hand, it results in a lower condensation pressure, which leads to a smaller annual consumption of energy by the compressor unit. As a result, the total amount of energy consumed by the refrigeration system decreases so that despite a higher cost of condensers designed to operate at lower values of temperature difference, it becomes possible to achieve the above-mentioned payback period. Additionally, the payback period in case of using an air-cooled microchannel aluminum condenser was calculated: in case of using such a condenser with a temperature difference of 8 K instead of the condenser with the temperature difference equal to 15 K, the payback period will be less than half a year. Recommendations for designing new refrigeration systems equipped with air-cooled condensers are given.

  8. Tandem air-agitated liquid-liquid microextraction as an efficient method for determination of acidic drugs in complicated matrices.

    PubMed

    Bazregar, Mohammad; Rajabi, Maryam; Yamini, Yadollah; Asghari, Alireza; Hemmati, Maryam

    2016-04-21

    A rapid and simple microextraction method with a high sample clean-up, termed as tandem air-agitated liquid-liquid microextraction (TAALLME), is described. This method is based upon the tandem implementation of the air-agitated liquid-liquid microextraction (AALLME), and this approach improves the applicability of the dispersive liquid-liquid microextraction (DLLME) methods in complicated matrices. With very simple tools, the three non-steroidal anti-inflammatory drugs diclofenac, ibuprofen, and mefenamic acid were efficiently extracted, with an overall extraction time of 7 min. By performing the first AALLME, these acidic analytes, contained in an aqueous sample solution (donor phase, 8.0 mL), were extracted into the organic solvent (1,2-dichloroethane, 37 μL), and their simple back-extraction into the aqueous acceptor solution (pH, 10.01, 51 μL) was obtained in 2 min by a second implementation of AALLME. Response surface methodology (RSM) was used for optimization of the experimental parameters. The pH values 2.94 and 10.01 were obtained for the donor and acceptor phases, respectively, and the volumes 99.5 and 51 μL were obtained for the organic solvent and the acceptor phase, respectively, as the optimal extraction conditions. Under the optimized conditions, tandem AALLME-HPLC-UV provided a good linearity in the range of 0.5-4000 ng mL(-1), limits of detection (0.1-0.3 ng mL(-1)), extraction repeatabilities (relative standard deviations (RSDs) below 7.7%, n = 5), and the enrichment factors (EFs) of 80-104. Finally, the applicability of the proposed method was evaluated by the extraction and determination of the drugs under study in the wastewater and human plasma samples. PMID:27026599

  9. Tandem air-agitated liquid-liquid microextraction as an efficient method for determination of acidic drugs in complicated matrices.

    PubMed

    Bazregar, Mohammad; Rajabi, Maryam; Yamini, Yadollah; Asghari, Alireza; Hemmati, Maryam

    2016-04-21

    A rapid and simple microextraction method with a high sample clean-up, termed as tandem air-agitated liquid-liquid microextraction (TAALLME), is described. This method is based upon the tandem implementation of the air-agitated liquid-liquid microextraction (AALLME), and this approach improves the applicability of the dispersive liquid-liquid microextraction (DLLME) methods in complicated matrices. With very simple tools, the three non-steroidal anti-inflammatory drugs diclofenac, ibuprofen, and mefenamic acid were efficiently extracted, with an overall extraction time of 7 min. By performing the first AALLME, these acidic analytes, contained in an aqueous sample solution (donor phase, 8.0 mL), were extracted into the organic solvent (1,2-dichloroethane, 37 μL), and their simple back-extraction into the aqueous acceptor solution (pH, 10.01, 51 μL) was obtained in 2 min by a second implementation of AALLME. Response surface methodology (RSM) was used for optimization of the experimental parameters. The pH values 2.94 and 10.01 were obtained for the donor and acceptor phases, respectively, and the volumes 99.5 and 51 μL were obtained for the organic solvent and the acceptor phase, respectively, as the optimal extraction conditions. Under the optimized conditions, tandem AALLME-HPLC-UV provided a good linearity in the range of 0.5-4000 ng mL(-1), limits of detection (0.1-0.3 ng mL(-1)), extraction repeatabilities (relative standard deviations (RSDs) below 7.7%, n = 5), and the enrichment factors (EFs) of 80-104. Finally, the applicability of the proposed method was evaluated by the extraction and determination of the drugs under study in the wastewater and human plasma samples.

  10. Lifestyle Physical Activity Behavior of Korean American Dry Cleaner Couples

    PubMed Central

    Sukyung, Ju; Wilbur, JoEllen; Eunice, Lee; Arlene, Miller

    2013-01-01

    Objective The purposes of this study were to: (1) describe and compare lifestyle physical activity (leisure-time, household, and occupational physical activity), using both self-report and an objective measure of step counts, in self-employed Korean American married couples working together at dry cleaners, and (2) examine the relationship between self-report and objective measures of physical activity. Design and Sample Seventy couples participated in this cross-sectional, descriptive, face-to-face interview survey. Measures Two self-reports (28-item Community Healthy Activities Model Program for Seniors Physical Activity Questionnaire and Tecumseh Occupational Physical Activity Questionnaire) and one objective measure (New Lifestyles-800 pedometer) were used. Results The husbands spent significantly more time than their wives in moderate- to vigorous-intensity leisure-time physical activity (207 vs. 122 minutes/week) and occupational physical activity (2,585 vs. 1,065 minutes/week). Most couples (91%) met recommended levels of physical activity based on their occupational physical activity. Pedometer steps correlated significantly only with leisure-time physical activity. Conclusions Study findings suggest that to increase physical activity in Korean American couples who work in a small business, moderate-intensity lifestyle physical activity interventions across leisure-time, household, and occupational physical activity will be more successful than traditional leisure-time interventions. In addition, results suggest that there is a need for interventions that target both members of the married couple. PMID:22092460

  11. Quality care means valuing care assistants, porters, and cleaners too.

    PubMed

    Toynbee, P

    2003-12-01

    All too often, the focus of the very clever strategy papers produced in the upper reaches of the health department is on the next grand plan. Some of these reforms have been catastrophic for the quality of service that patients experience at ward level. Of these, the contracting out culture introduced in the 1980s and the 1990s has been the worst. Researching my book, Hard work-life in low pay Britain, I took six jobs at around the minimum wage, including work as a hospital porter, as a hospital cleaner, and as a care assistant. These are jobs at the sharp end, up close and very personal to the patients, strongly influencing their experiences of the services they were using. Yet they are low paid, undervalued jobs that fall below the radar of the policy makers. In hospitals they need to be brought back in-house and integrated into a team ethos. Paying these people more would cost more, but it would also harvest great rewards by using their untapped commitment.

  12. Ammonium Laurate Surfactant for Cleaner Deposition of Carbon Nanotubes.

    PubMed

    Nilsson, Hanna M; Meany, Brendan; Ticey, Jeremy; Sun, Chuan-Fu; Wang, YuHuang; Cumings, John

    2015-06-30

    Experiments probing the properties of individual carbon nanotubes (CNTs) and those measuring bulk composites show vastly different results. One major issue limiting the results is that the procedures required to separate and test CNTs introduce contamination that changes the properties of the CNT. These contamination residues often come from the resist used in lithographic processing and the surfactant used to suspend and deposit the CNTs, commonly sodium dodecyl sulfate (SDS). Here we present ammonium laurate (AL), a surfactant that has previously not been used for this application, which differs from SDS only by substitution of ionic constituents but shows vastly cleaner depositions. In addition, we show that compared to SDS, AL-suspended CNTs have greater shelf stability and more selective dispersion. These results are verified using transmission electron microscopy, atomic force microscopy, ζ-potential measurements, and Raman and absorption optical spectroscopy. This surfactant is simple to prepare, and the nanotube solutions require minimal sonication and centrifugation in order to outperform SDS. PMID:26020583

  13. Highly efficient photocatalytic TiO2 coatings deposited by open air atmospheric pressure plasma jet with aerosolized TTIP precursor

    NASA Astrophysics Data System (ADS)

    Fakhouri, H.; Ben Salem, D.; Carton, O.; Pulpytel, J.; Arefi-Khonsari, F.

    2014-07-01

    A simple method to deposit photocatalytic TiO2 coatings, at a high rate (20-40 µm s-1), and with a high porosity, is reported in this paper. This method, which allows the treatment of membranes (with an 800 nm pore size), is based on the introduction of a liquid precursor sprayed into an open-air atmospheric pressure plasma jet (APPJ). The photocatalytic activity of the TiO2 thin films prepared by APPJ have been compared with our best N-doped TiO2 thin films, deposited by reactive radio frequency (RF) magnetron sputtering, previously reported in the literature. The morphology, chemical composition, photoelectrochemical, and photocatalytic properties of the coatings have been studied in this paper. Significant control of the porosity and crystallinity was achieved by varying the deposition parameters and the annealing temperature. Under optimized conditions, the TiO2 coatings deposited by APPJ are characterized by a higher photocatalytic activity as compared to the optimized thin films deposited by RF sputtering. This difference can be explained by the higher specific surface of the APPJ coatings. Finally, the most interesting characteristic of this APPJ-liquid spray process is its capacity to treat membranes without blocking the pores, and to produce photocatalytic membranes which can efficiently combine filtration and photocatalysis for water treatment.

  14. An efficient dye-sensitized BiOCl photocatalyst for air and water purification under visible light irradiation.

    PubMed

    Li, Guisheng; Jiang, Bo; Xiao, Shuning; Lian, Zichao; Zhang, Dieqing; Yu, Jimmy C; Li, Hexing

    2014-08-01

    A photosensitized BiOCl catalyst was found to be effective for photocatalytic water purification and air remediation under visible light irradiation (λ > 420 nm). Prepared by a solvothermal method, the BiOCl crystals possessed a 3D hierarchical spherical structure with the highly active facets exposed. When sensitized by Rhodamine B (RhB), the photocatalyst system was more active than N-doped TiO2 for breaking down 4-chlorophenol (4-CP, 200 ppm) and nitric monoxide (NO, 500 ppb). The high activity could be attributed to the hierarchical structure (supplying feasible reaction tunnels for adsorption and transition of reactants or products) and the efficient exposure of the {001} facets. The former provides an enriched oxygen atom density that promotes adsorption of cationic dye RhB, and creates an oxygen vacancy state. The HO˙ and ˙O2(-) radicals produced from the injected electrons from the excited dye molecule (RhB*) into the conduction band of BiOCl were responsible for the excellent photocatalytic performance of the RhB-BiOCl system.

  15. Controllable Growth of Perovskite Films by Room-Temperature Air Exposure for Efficient Planar Heterojunction Photovoltaic Cells

    SciTech Connect

    Yang, Bin; Dyck, Ondrej; Poplawsky, Jonathan; Keum, Jong; Das, Sanjib; Puretzky, Alexander; Aytug, Tolga; Joshi, Pooran C.; Rouleau, Christopher M.; Duscher, Gerd; Geohegan, David B.; Xiao, Kai

    2015-12-01

    A two-step-solution-processing approach has been established to grow void-free perovskite films for low-cost and high-performance planar heterojunction photovoltaic devices. We generally applied a high-temperature thermal annealing treatment in order to drive the diffusion of CH3NH3I precursor molecules into the compact PbI2 layer to form perovskite films. But, thermal annealing for extended periods would lead to degraded device performance due to the defects generated by decomposition of perovskite into PbI2. In this work, we explored a controllable layer-by-layer spin-coating method to grow bilayer CH3NH3I/PbI2 films, and then drive the interdiffusion between PbI2 and CH3NH3I layers by a simple room-temperature-air-exposure for making well-oriented, highly-crystalline perovskite films without thermal annealing. This high degree of crystallinity resulted in a carrier diffusion length of ~ 800 nm and high device efficiency of 15.6%, which is comparable to the reported values from thermally-annealed perovskite films based counterparts. Finally, the simplicity and high device performance of this processing approach is highly promising for direct integration into industrial-scale device manufacture.

  16. Controllable Growth of Perovskite Films by Room-Temperature Air Exposure for Efficient Planar Heterojunction Photovoltaic Cells

    DOE PAGES

    Yang, Bin; Dyck, Ondrej; Poplawsky, Jonathan; Keum, Jong; Das, Sanjib; Puretzky, Alexander; Aytug, Tolga; Joshi, Pooran C.; Rouleau, Christopher M.; Duscher, Gerd; et al

    2015-12-01

    A two-step-solution-processing approach has been established to grow void-free perovskite films for low-cost and high-performance planar heterojunction photovoltaic devices. We generally applied a high-temperature thermal annealing treatment in order to drive the diffusion of CH3NH3I precursor molecules into the compact PbI2 layer to form perovskite films. But, thermal annealing for extended periods would lead to degraded device performance due to the defects generated by decomposition of perovskite into PbI2. In this work, we explored a controllable layer-by-layer spin-coating method to grow bilayer CH3NH3I/PbI2 films, and then drive the interdiffusion between PbI2 and CH3NH3I layers by a simple room-temperature-air-exposure for makingmore » well-oriented, highly-crystalline perovskite films without thermal annealing. This high degree of crystallinity resulted in a carrier diffusion length of ~ 800 nm and high device efficiency of 15.6%, which is comparable to the reported values from thermally-annealed perovskite films based counterparts. Finally, the simplicity and high device performance of this processing approach is highly promising for direct integration into industrial-scale device manufacture.« less

  17. Controllable Growth of Perovskite Films by Room-Temperature Air Exposure for Efficient Planar Heterojunction Photovoltaic Cells.

    PubMed

    Yang, Bin; Dyck, Ondrej; Poplawsky, Jonathan; Keum, Jong; Das, Sanjib; Puretzky, Alexander; Aytug, Tolga; Joshi, Pooran C; Rouleau, Christopher M; Duscher, Gerd; Geohegan, David B; Xiao, Kai

    2015-12-01

    A two-step solution processing approach has been established to grow void-free perovskite films for low-cost high-performance planar heterojunction photovoltaic devices. A high-temperature thermal annealing treatment was applied to drive the diffusion of CH3NH3I precursor molecules into a compact PbI2 layer to form perovskite films. However, thermal annealing for extended periods led to degraded device performance owing to the defects generated by decomposition of perovskite into PbI2. A controllable layer-by-layer spin-coating method was used to grow "bilayer" CH3NH3I/PbI2 films, and then drive the interdiffusion between PbI2 and CH3NH3I layers by a simple air exposure at room temperature for making well-oriented, highly crystalline perovskite films without thermal annealing. This high degree of crystallinity resulted in a carrier diffusion length of ca. 800 nm and a high device efficiency of 15.6%, which is comparable to values reported for thermally annealed perovskite films.

  18. Controllable Growth of Perovskite Films by Room-Temperature Air Exposure for Efficient Planar Heterojunction Photovoltaic Cells.

    PubMed

    Yang, Bin; Dyck, Ondrej; Poplawsky, Jonathan; Keum, Jong; Das, Sanjib; Puretzky, Alexander; Aytug, Tolga; Joshi, Pooran C; Rouleau, Christopher M; Duscher, Gerd; Geohegan, David B; Xiao, Kai

    2015-12-01

    A two-step solution processing approach has been established to grow void-free perovskite films for low-cost high-performance planar heterojunction photovoltaic devices. A high-temperature thermal annealing treatment was applied to drive the diffusion of CH3NH3I precursor molecules into a compact PbI2 layer to form perovskite films. However, thermal annealing for extended periods led to degraded device performance owing to the defects generated by decomposition of perovskite into PbI2. A controllable layer-by-layer spin-coating method was used to grow "bilayer" CH3NH3I/PbI2 films, and then drive the interdiffusion between PbI2 and CH3NH3I layers by a simple air exposure at room temperature for making well-oriented, highly crystalline perovskite films without thermal annealing. This high degree of crystallinity resulted in a carrier diffusion length of ca. 800 nm and a high device efficiency of 15.6%, which is comparable to values reported for thermally annealed perovskite films. PMID:26486584

  19. Evaluation of a high efficiency cabin air (HECA) filtration system for reducing particulate pollutants inside school buses.

    PubMed

    Lee, Eon S; Fung, Cha-Chen D; Zhu, Yifang

    2015-03-17

    An increasing number of studies have reported deleterious health effects of vehicle-emitted particulate matter (PM), including PM2.5 (aerodynamic diameter≤2.5 μm), black carbon (BC), and ultrafine particles (UFPs, diameter≤100 nm). When commuting inside school buses, children are exposed to high level of these pollutants due to emissions from both school bus itself and other on-road vehicles. This study developed an on-board high efficiency cabin air (HECA) filtration system for reducing children's exposure inside school buses. Six school buses were driven on two typical routes to evaluate to what extent the system reduces particulate pollutant levels inside the buses. The testing routes included freeways and major arterial roadways in Los Angeles, CA. UFP number concentrations and size distributions as well as BC and PM2.5 concentrations were monitored concurrently inside and outside of each bus. With the HECA filtration system on, in-cabin UFP and BC levels were reduced by 88±6% and 84±5% on averages across all driving conditions, respectively. The system was less effective for PM2.5 (55±22%) but successfully kept its levels below 12 μg/m3 inside all the buses. For all three types of particulate pollutants, in-cabin reductions were higher on freeways than on arterial roadways.

  20. Evaluation of a high efficiency cabin air (HECA) filtration system for reducing particulate pollutants inside school buses.

    PubMed

    Lee, Eon S; Fung, Cha-Chen D; Zhu, Yifang

    2015-03-17

    An increasing number of studies have reported deleterious health effects of vehicle-emitted particulate matter (PM), including PM2.5 (aerodynamic diameter≤2.5 μm), black carbon (BC), and ultrafine particles (UFPs, diameter≤100 nm). When commuting inside school buses, children are exposed to high level of these pollutants due to emissions from both school bus itself and other on-road vehicles. This study developed an on-board high efficiency cabin air (HECA) filtration system for reducing children's exposure inside school buses. Six school buses were driven on two typical routes to evaluate to what extent the system reduces particulate pollutant levels inside the buses. The testing routes included freeways and major arterial roadways in Los Angeles, CA. UFP number concentrations and size distributions as well as BC and PM2.5 concentrations were monitored concurrently inside and outside of each bus. With the HECA filtration system on, in-cabin UFP and BC levels were reduced by 88±6% and 84±5% on averages across all driving conditions, respectively. The system was less effective for PM2.5 (55±22%) but successfully kept its levels below 12 μg/m3 inside all the buses. For all three types of particulate pollutants, in-cabin reductions were higher on freeways than on arterial roadways. PMID:25728749

  1. An efficient dye-sensitized BiOCl photocatalyst for air and water purification under visible light irradiation.

    PubMed

    Li, Guisheng; Jiang, Bo; Xiao, Shuning; Lian, Zichao; Zhang, Dieqing; Yu, Jimmy C; Li, Hexing

    2014-08-01

    A photosensitized BiOCl catalyst was found to be effective for photocatalytic water purification and air remediation under visible light irradiation (λ > 420 nm). Prepared by a solvothermal method, the BiOCl crystals possessed a 3D hierarchical spherical structure with the highly active facets exposed. When sensitized by Rhodamine B (RhB), the photocatalyst system was more active than N-doped TiO2 for breaking down 4-chlorophenol (4-CP, 200 ppm) and nitric monoxide (NO, 500 ppb). The high activity could be attributed to the hierarchical structure (supplying feasible reaction tunnels for adsorption and transition of reactants or products) and the efficient exposure of the {001} facets. The former provides an enriched oxygen atom density that promotes adsorption of cationic dye RhB, and creates an oxygen vacancy state. The HO˙ and ˙O2(-) radicals produced from the injected electrons from the excited dye molecule (RhB*) into the conduction band of BiOCl were responsible for the excellent photocatalytic performance of the RhB-BiOCl system. PMID:24934740

  2. High-efficiency dye-sensitized solar cells of up to 8.03% by air plasma treatment of ZnO nanostructures.

    PubMed

    He, Yitao; Hu, Jing; Xie, Yahong

    2015-11-21

    By using the simple but effective method-air plasma to treat the precursor Zn(OH)2, the hydrogen-related defects in ZnO, which lead to increased charge carrier recombination, have been reduced. Successfully, a photoelectric conversion efficiency of 8.03% for pure ZnO-based DSSCs has been achieved, which is the highest one up to now.

  3. Energy Efficiency and Indoor Environmental Quality in Schools. A Joint EPA Working Paper from Energy Star[R] and Indoor Air Quality.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.

    This paper describes how to protect and enhance indoor environmental quality without sacrificing energy performance, lists the common pollutants and their sources, and explores how energy efficiency projects affect indoor environmental quality. Also highlighted are study figures showing the energy costs of outdoor air ventilation and an…

  4. The effect of air flow on the temperature distribution and the harmonic conversion efficiency of the ADP crystal with large aperture in the temperature control scheme

    NASA Astrophysics Data System (ADS)

    Sun, Fuzhong; Zhang, Peng; Lu, Lihua; Xiang, Yong; Bai, Qingshun

    2016-03-01

    This paper presented a temperature control scheme for ammonium dihydrogen phosphate (ADP) crystal of V80 mm in diameter, and the influence of the air flow was also studied. This research aims to obtain the high energy, high frequency laser with large aperture under the non-critical phase matching (NCPM). Firstly, thermal analysis was carried out to investigate the air flow property in the cavity, as well as the effect of ambient temperature was analyzed. Secondly, the temperature distributions of air flow were achieved using the Finite Volume Method (FVM), and this prediction was validated by the experiment results. Finally, the effect of air flow in the cavity was obtained from the heating method, and the variation of harmonic conversion efficiency caused by the ambient temperature was also highlighted.

  5. Radioactive air emissions notice of construction HEPA filtered vacuum radioactive air emission units

    SciTech Connect

    JOHNSON, R.E.

    1999-09-01

    This notice of construction (NOC) requests a categorical approval for construction and operation of certain portable high-efficiency particulate air (HEPA) filtered vacuum radionuclide airborne emission units (HVUs). Approval of this NOC application is intended to allow operation of the HVUs without prior project-specific approval. This NOC does not request replacement or supersedence of any previous agreements/approvals by the Washington State Department of Health for the use of vacuums on the Hanford Site. These previous agreement/approvals include the approved NOCs for the use of EuroClean HEPA vacuums at the T Plant Complex (routine technical meeting 12/10/96) and the Kelly Decontamination System at the Plutonium-Uranium Extraction (PUREX) Plant (routine technical meeting 06/25/96). Also, this NOC does not replace or supersede the agreement reached regarding the use of HEPA hand-held/shop-vacuum cleaners for routine cleanup activities conducted by the Environmental Restoration Project. Routine cleanup activities are conducted during the surveillance and maintenance of inactive waste sites (Radioactive Area Remedial Action Project) and inactive facilities. HEPA hand-held/shop-vacuum cleaners are used to clean up spot surface contamination areas found during outdoor radiological field surveys, and to clean up localized radiologically contaminated material (e.g., dust, dirt, bird droppings, animal feces, liquids, insects, spider webs, etc.). This agreement, documented in the October 12, 1994 Routine Meeting Minutes, is based on routine cleanup consisting of spot cleanup of low-level contamination provided that, in each case, the source term potential would be below 0.1 millirem per year.

  6. Presence of cleaner wrasse increases the recruitment of damselfishes to coral reefs.

    PubMed

    Sun, Derek; Cheney, Karen L; Werminghausen, Johanna; Meekan, Mark G; McCormick, Mark I; Cribb, Thomas H; Grutter, Alexandra S

    2015-08-01

    Mutualisms affect the biodiversity, distribution and abundance of biological communities. However, ecological processes that drive mutualism-related shifts in population structure are often unclear and must be examined to elucidate how complex, multi-species mutualistic networks are formed and structured. In this study, we investigated how the presence of key marine mutualistic partners can drive the organisation of local communities on coral reefs. The cleaner wrasse, Labroides dimidiatus, removes ectoparasites and reduces stress hormones for multiple reef fish species, and their presence on coral reefs increases fish abundance and diversity. Such changes in population structure could be driven by increased recruitment of larval fish at settlement, or by post-settlement processes such as modified levels of migration or predation. We conducted a controlled field experiment to examine the effect of cleaners on recruitment processes of a common group of reef fishes, and showed that small patch reefs (61-285 m(2)) with cleaner wrasse had higher abundances of damselfish recruits than reefs from which cleaner wrasse had been removed over a 12-year period. However, the presence of cleaner wrasse did not affect species diversity of damselfish recruits. Our study provides evidence of the ecological processes that underpin changes in local population structure in the presence of a key mutualistic partner. PMID:26289440

  7. Presence of cleaner wrasse increases the recruitment of damselfishes to coral reefs

    PubMed Central

    Sun, Derek; Cheney, Karen L.; Werminghausen, Johanna; Meekan, Mark G.; McCormick, Mark I.; Cribb, Thomas H.; Grutter, Alexandra S.

    2015-01-01

    Mutualisms affect the biodiversity, distribution and abundance of biological communities. However, ecological processes that drive mutualism-related shifts in population structure are often unclear and must be examined to elucidate how complex, multi-species mutualistic networks are formed and structured. In this study, we investigated how the presence of key marine mutualistic partners can drive the organisation of local communities on coral reefs. The cleaner wrasse, Labroides dimidiatus, removes ectoparasites and reduces stress hormones for multiple reef fish species, and their presence on coral reefs increases fish abundance and diversity. Such changes in population structure could be driven by increased recruitment of larval fish at settlement, or by post-settlement processes such as modified levels of migration or predation. We conducted a controlled field experiment to examine the effect of cleaners on recruitment processes of a common group of reef fishes, and showed that small patch reefs (61–285 m2) with cleaner wrasse had higher abundances of damselfish recruits than reefs from which cleaner wrasse had been removed over a 12-year period. However, the presence of cleaner wrasse did not affect species diversity of damselfish recruits. Our study provides evidence of the ecological processes that underpin changes in local population structure in the presence of a key mutualistic partner. PMID:26289440

  8. Cortisol mediates cleaner wrasse switch from cooperation to cheating and tactical deception.

    PubMed

    Soares, Marta C; Cardoso, Sónia C; Grutter, Alexandra S; Oliveira, Rui F; Bshary, Redouan

    2014-07-01

    Recent empirical research, mostly done on humans, recognizes that individuals' physiological state affects levels of cooperation. An individual's internal state may affect the payoffs of behavioural alternatives, which in turn could influence the decision to either cooperate or to defect. However, little is known about the physiology underlying condition dependent cooperation. Here, we demonstrate that shifts in cortisol levels affect levels of cooperation in wild cleaner wrasse Labroides dimidiatus. These cleaners cooperate by removing ectoparasites from visiting 'client' reef fishes but prefer to eat client mucus, which constitutes cheating. We exogenously administrated one of three different compounds to adults, that is, (a) cortisol, (b) glucocorticoid receptor antagonist mifepristone RU486 or (c) sham (saline), and observed their cleaning behaviour during the following 45min. The effects of cortisol match an earlier observational study that first described the existence of "cheating" cleaners: such cleaners provide small clients with more tactile stimulation with their pectoral and pelvic fins, a behaviour that attracts larger clients that are then bitten to obtain mucus. Blocking glucocorticoid receptors led to more tactile stimulation to large clients. As energy demands and associated cortisol concentration level shifts affect cleaner wrasse behavioural patterns, cortisol potentially offers a general mechanism for condition dependent cooperation in vertebrates. PMID:24952103

  9. Cortisol mediates cleaner wrasse switch from cooperation to cheating and tactical deception.

    PubMed

    Soares, Marta C; Cardoso, Sónia C; Grutter, Alexandra S; Oliveira, Rui F; Bshary, Redouan

    2014-07-01

    Recent empirical research, mostly done on humans, recognizes that individuals' physiological state affects levels of cooperation. An individual's internal state may affect the payoffs of behavioural alternatives, which in turn could influence the decision to either cooperate or to defect. However, little is known about the physiology underlying condition dependent cooperation. Here, we demonstrate that shifts in cortisol levels affect levels of cooperation in wild cleaner wrasse Labroides dimidiatus. These cleaners cooperate by removing ectoparasites from visiting 'client' reef fishes but prefer to eat client mucus, which constitutes cheating. We exogenously administrated one of three different compounds to adults, that is, (a) cortisol, (b) glucocorticoid receptor antagonist mifepristone RU486 or (c) sham (saline), and observed their cleaning behaviour during the following 45min. The effects of cortisol match an earlier observational study that first described the existence of "cheating" cleaners: such cleaners provide small clients with more tactile stimulation with their pectoral and pelvic fins, a behaviour that attracts larger clients that are then bitten to obtain mucus. Blocking glucocorticoid receptors led to more tactile stimulation to large clients. As energy demands and associated cortisol concentration level shifts affect cleaner wrasse behavioural patterns, cortisol potentially offers a general mechanism for condition dependent cooperation in vertebrates.

  10. Presence of cleaner wrasse increases the recruitment of damselfishes to coral reefs.

    PubMed

    Sun, Derek; Cheney, Karen L; Werminghausen, Johanna; Meekan, Mark G; McCormick, Mark I; Cribb, Thomas H; Grutter, Alexandra S

    2015-08-01

    Mutualisms affect the biodiversity, distribution and abundance of biological communities. However, ecological processes that drive mutualism-related shifts in population structure are often unclear and must be examined to elucidate how complex, multi-species mutualistic networks are formed and structured. In this study, we investigated how the presence of key marine mutualistic partners can drive the organisation of local communities on coral reefs. The cleaner wrasse, Labroides dimidiatus, removes ectoparasites and reduces stress hormones for multiple reef fish species, and their presence on coral reefs increases fish abundance and diversity. Such changes in population structure could be driven by increased recruitment of larval fish at settlement, or by post-settlement processes such as modified levels of migration or predation. We conducted a controlled field experiment to examine the effect of cleaners on recruitment processes of a common group of reef fishes, and showed that small patch reefs (61-285 m(2)) with cleaner wrasse had higher abundances of damselfish recruits than reefs from which cleaner wrasse had been removed over a 12-year period. However, the presence of cleaner wrasse did not affect species diversity of damselfish recruits. Our study provides evidence of the ecological processes that underpin changes in local population structure in the presence of a key mutualistic partner.

  11. Effect of Air Cooling of Turbine Disk on Power and Efficiency of Turbine from Turbo Engineering Corporation TT13-18 Turbosupercharger.

    NASA Technical Reports Server (NTRS)

    Berkey, William E.

    1949-01-01

    An investigation was conducted to determine the effect of turbine-disk cooling with air on the efficiency and the power output of the radial-flow turbine from the Turbo Engineering Corporation TT13-18 turbosupercharger. The turbine was operated at a constant range of ratios of turbine-inlet total pressure to turbine-outlet static pressure of 1,5 and 2.0, turbine-inlet total pressure of 30 inches mercury absolute, turbine-inlet total temperature of 12000 to 20000 R, and rotor speeds of 6000 to 22,000 rpm, Over the normal operating range of the turbine, varying the corrected cooling-air weight flow from approximately 0,30 to 0.75 pound per second produced no measurable effect on the corrected turbine shaft horsepower or the turbine shaft adiabatic efficiency. Varying the turbine-inlet total temperature from 12000 to 20000 R caused no measurable change in the corrected cooling-air weight flow. Calculations indicated that the cooling-air pumping power in the disk passages was small and was within the limits of the accuracy of the power measurements. For high turbine power output, the power loss to the compressor for compressing the cooling air was approximately 3 percent of the total turbine shaft horsepower.

  12. Application of a high-efficiency cabin air filter for simultaneous mitigation of ultrafine particle and carbon dioxide exposures inside passenger vehicles.

    PubMed

    Lee, Eon S; Zhu, Yifang

    2014-02-18

    Modern passenger vehicles are commonly equipped with cabin air filters but their filtration efficiency for ultrafine particle (UFP) is rather low. Although setting the vehicle ventilation system to recirculation (RC) mode can reduce in-cabin UFPs by ∼ 90%, passenger-exhaled carbon dioxide (CO2) can quickly accumulate inside the cabin. Using outdoor air (OA) mode instead can provide sufficient air exchange to prevent CO2 buildup, but in-cabin UFP concentrations would increase. To overcome this dilemma, we developed a simultaneous mitigation method for UFP and CO2 using high-efficiency cabin air (HECA) filtration in OA mode. Concentrations of UFP and other air pollutants were simultaneously monitored in and out of 12 different vehicles under 3 driving conditions: stationary, on local roadways, and on freeways. Under each experimental condition, data were collected with no filter, in-use original equipment manufacturer (OEM) filter, and two types of HECA filters. The HECA filters offered an average in-cabin UFP reduction of 93%, much higher than the OEM filters (∼ 50% on average). Throughout the measurements, the in-cabin CO2 concentration remained in the range of 620-930 ppm, significantly lower than the typical level of 2500-4000 ppm observed in the RC mode. PMID:24471775

  13. Enabling the environmentally clean air transportation of the future: a vision of computational fluid dynamics in 2030.

    PubMed

    Slotnick, Jeffrey P; Khodadoust, Abdollah; Alonso, Juan J; Darmofal, David L; Gropp, William D; Lurie, Elizabeth A; Mavriplis, Dimitri J; Venkatakrishnan, Venkat

    2014-08-13

    As global air travel expands rapidly to meet demand generated by economic growth, it is essential to continue to improve the efficiency of air transportation to reduce its carbon emissions and address concerns about climate change. Future transports must be 'cleaner' and designed to include technologies that will continue to lower engine emissions and reduce community noise. The use of computational fluid dynamics (CFD) will be critical to enable the design of these new concepts. In general, the ability to simulate aerodynamic and reactive flows using CFD has progressed rapidly during the past several decades and has fundamentally changed the aerospace design process. Advanced simulation capabilities not only enable reductions in ground-based and flight-testing requirements, but also provide added physical insight, and enable superior designs at reduced cost and risk. In spite of considerable success, reliable use of CFD has remained confined to a small region of the operating envelope due, in part, to the inability of current methods to reliably predict turbulent, separated flows. Fortunately, the advent of much more powerful computing platforms provides an opportunity to overcome a number of these challenges. This paper summarizes the findings and recommendations from a recent NASA-funded study that provides a vision for CFD in the year 2030, including an assessment of critical technology gaps and needed development, and identifies the key CFD technology advancements that will enable the design and development of much cleaner aircraft in the future. PMID:25024413

  14. 40 CFR 86.1868-12 - CO2 credits for improving the efficiency of air conditioning systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., interior volume, climate control system type and characteristics, refrigerant used, compressor type, and... recirculated air when the operator or the automatic climate control system has engaged the air conditioning... subsequent vehicle operations (i.e., next vehicle start). The climate control system may delay switching...

  15. 40 CFR 86.1868-12 - CO2 credits for improving the efficiency of air conditioning systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... years. (1) The manufacturer shall perform the AC17 test specified in 40 CFR 1066.845 on each unique air... calculations required in 40 CFR 1066.845 must also be reported. In each subsequent model year additional air... may be carried over to subsequent model years until there is a significant change in the...

  16. Correlation of chain length compatibility and surface properties of mixed foaming agents with fluid displacement efficiency and effective air mobility in porous media

    SciTech Connect

    Sharma, M.K.; Bringham, W.E.; Shah, D.O.

    1984-05-01

    The effects of chain length compatibility and surface properties of mixed foaming agents on fluid displacement efficiency and effective air mobility in porous media were investigated. Sodium dodecyl sulfate (C/sub 12/H/sub 25/SO/sub 4/Na) and various alkyl alcohols (e.g., C/sub 8/OH,C/sub 10/OH,C/sub 12/OH,C/sub 14/OH, and C/sub 16/OH) were used as mixed foaming agents. It was observed that the surface properties of surfactant solutions and flow behavior of foams through porous media were influenced by the chain length compatibility of the surfactant molecules. The increase in the length of porous media improved fluid displacement efficiency while breakthrough time per unit length decreased slightly with increase in the length of porous media. For mixed surfactant systems, a minimum in surface tension, a maximum in surface viscosity, a minimum in bubble size, a maximum in breakthrough time, a maximum in fluid displacement efficiency, and a minimum in effective air mobility were observed when the two components of the surfactant system had the same chain length. These results indicate that the surface properties of foaming solutions and molecular packing at interfaces exhibit a striking correlation with breakthrough time, fluid displacement efficiency, and effective air mobility in porous media.

  17. Participatory ergonomics and an evaluation of a low-cost improvement effect on cleaners' working posture.

    PubMed

    Kumar, Rupesh; Chaikumarn, Montakarn; Lundberg, Jan

    2005-01-01

    Cleaning is a highly physically demanding job with a high frequency of awkward postures and working environments as contributing risk factors. Participatory ergonomics is a method in which end-users take an active role in identifying risk factors and solutions. The aim of this study was to apply the participatory ergonomics method to identify cleaning problems and to evaluate the effect of a low-cost improvement on cleaners' working postures in an office environment. The results show that the cleaning problem was identified, and the low-cost ergonomics solution suggested by the cleaners was implemented. Thus an improved working environment reduced the number of awkward cleaning postures and the Ovako Working Posture Analysis System (OWAS) action category for floor mopping decreased. It can be concluded that working in an improved environment can lead to better working postures which, in turn, leads to the cleaners' better health and better cleaning results.

  18. Determining the EDTA Content in a Consumer Shower Cleaner. An Introductory Chemistry Laboratory Experiment

    NASA Astrophysics Data System (ADS)

    Weigand, Willis A.

    2000-10-01

    At Altoona College, Chemistry 11 is offered to students as a preparatory course for the University's Chemical Principles course, Chem 12. A relevant laboratory is a source of motivation for the students to learn the chemistry. One way of making the laboratory relevant is to analyze the chemical components of consumer products. Several new shower-cleaning products have been introduced, which advertise that cleaning the shower is no longer necessary. The cleaners work using a combination of surfactants, alcohols, and a chelating agent. The Web site of a popular shower cleaner lists EDTA (ethylenediamine tetraacetate ion) as the chelating agent. The classic EDTA/calcium complexometric titration can be used to determine the EDTA content of the cleaner. This article describes the experiment to determine the EDTA content in a shower-cleaning product.

  19. Power and temptation cause shifts between exploitation and cooperation in a cleaner wrasse mutualism

    PubMed Central

    Gingins, Simon; Werminghausen, Johanna; Johnstone, Rufus A.; Grutter, Alexandra S.; Bshary, Redouan

    2013-01-01

    In many instances of cooperation, only one individual has both the potential and the incentive to ‘cheat’ and exploit its partner. Under these asymmetric conditions, a simple model predicts that variation in the temptation to cheat and in the potential victim's capacity for partner control leads to shifts between exploitation and cooperation. Here, we show that the threat of early termination of an interaction was sufficient to induce cleaner wrasse Labroides dimidiatus to feed selectively against their preference (which corresponds to cooperatively eating client fish ectoparasites), provided that their preference for alternative food was weak. Under opposite conditions, cleaners fed selectively according to their own preference (which corresponds to cheating by eating client mucus). By contrast, a non-cleaning fish species, Halichoeres melanurus, failed to adjust its foraging behaviour under these same conditions. Thus, cleaners appear to have evolved the power to strategically adjust their levels of cooperation according to the circumstances. PMID:23615288

  20. Experimental investigation of the formaldehyde removal mechanisms in a dynamic botanical filtration system for indoor air purification.

    PubMed

    Wang, Zhiqiang; Pei, Jingjing; Zhang, Jensen S

    2014-09-15

    Botanical filtration has been proved to be effective for indoor gas pollutant removal. To understand the roles of different transport, storage and removal mechanism by a dynamic botanical air filter, a series of experimental investigations were designed and conducted in this paper. Golden Pothos (Epipremnum aureum) plants was selected for test, and its original soil or activated/pebbles root bed was used in different test cases. It was found that flowing air through the root bed with microbes dynamically was essential to obtain meaningful formaldehyde removal efficiency. For static potted plant as normally place in rooms, the clean air delivery rate (CADR), which is often used to quantify the air cleaning ability of portable air cleaners, was only ∼ 5.1m(3)/h per m(2) bed, while when dynamically with air flow through the bed, the CADR increased to ∼ 233 m(3)/h per m(2) bed. The calculated CADR due to microbial activity is ∼ 108 m(3)/h per m(2) bed. Moisture in the root bed also played an important role, both for maintaining a favorable living condition for microbes and for absorbing water-soluble compounds such as formaldehyde. The role of the plant was to introduce and maintain a favorable microbe community which effectively degraded the volatile organic compounds adsorbed or absorbed by the root bed. The presence of the plant increased the removal efficiency by a factor of two based on the results from the bench-scale root bed experiments.