Science.gov

Sample records for air cleaning equipment

  1. Cleaning supplies and equipment

    MedlinePlus

    ... something means to clean it to destroy germs. Disinfectants are the cleaning solutions that are used to ... each solution. You may need to allow the disinfectant to dry on the equipment for a set ...

  2. 77 FR 41930 - Bleed Air Cleaning and Monitoring Equipment and Technology

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-17

    ... Privacy Act Statement can be found in the Federal Register published on April 11, 2000 (65 FR 19477-19478... industry developers, manufacturers, and the public related to effective air cleaning technology and...

  3. Adsorption air cleaning from ozone.

    PubMed

    Baltrenas, Pranas; Paliulis, Dainius; Vasarevicius, Saulius; Simaitis, Ramutis

    2003-01-01

    Not much has been written about air cleaning from ozone. The aim of this paper was to demonstrate the possibility of adsorption air cleaning from ozone. The second aim was to investigate the dependence of the efficiency of ozone removal from the air on the height of the adsorber layer and on concentrations of ozone, and to obtain empirical formulas for calculating the efficiency of ozone treatment. Equipment for air cleaning from ozone and nitrogen and sulphur dioxides is suggested.

  4. Photocatalytic equipment with nitrogen-doped titanium dioxide for air cleaning and disinfecting

    NASA Astrophysics Data System (ADS)

    Son Le, Thanh; Buu Ngo, Quoc; Dung Nguyen, Viet; Chau Nguyen, Hoai; Hien Dao, Trong; Tin Tran, Xuan; Kabachkov, E. N.; Balikhin, I. L.

    2014-03-01

    Nitrogen-doped TiO2 nanoparticle photocatalysts were synthesized by a sol-gel procedure using tetra-n-butyl orthotitanate as a titanium precursor and urea as a nitrogen source. Systematic studies for the preparation parameters and their impact on the material's structure were carried out by multiple techniques: thermogravimetric and differential scanning calorimetric analysis, x-ray diffraction, scanning electron microscope, transmission electron microscopy, energy dispersive x-ray spectroscopy and UV-Vis diffuse reflectance spectrophotometry showed that the nitrogen-doped TiO2 calcined at 500 °C for 3 h exhibited a spherical form with a particle size about 15-20 nm and crystal phase presented a mixture of 89.12% anatase. The obtained product was deposited on a porous quartz tube (D = 74 mm l = 418 mm) to manufacture an air photocatalytic cleaner as a prototype of the TIOKRAFT company's equipment. The created air cleaner was able to remove 60% of 10 ppm acetone within 390 min and degrade 98.5% of bacteria (total aerobic bacteria and fungi, 300 cfu m-3) within 120 min in a 10 m3 box. These photodegradation activities of N-TiO2 are higher than that of the commercial nano-TiO2 (Skyspring Inc., USA, particle size of 5-10 nm).

  5. Cleaning equipment for cleaning and degreasing

    SciTech Connect

    Gavaskar, A.R.

    1995-09-01

    Cleaning and degreasing processes are applied in industries to remove dirt, oil, and grease (together referred to as soil) from manufactured parts. In the metal-finishing industry, cleaning usually follows machining and precedes other surface-finishing steps such as rust inhibition or electroplating. During machining, a variety of oil emulsions or synthetic fluids are sprayed on the workpiece (parts being fabricated) for lubrication and cooling. These fluids must be removed before final finishing. The slightest amount of oil or other residue can render the final surface finish ineffective. Solvents have traditionally been used for cleaning and are widely used during processing in the metal-finishing, dry-cleaning, and electronics industries, as well as in a variety of other industries during maintenance. Solvent cleaning leads to air emissions and occupational exposure during use and environmental hazards during disposal of the spent solvent. Pollution prevention efforts focus on reducing or eliminating use of these solvents.

  6. Nuclear air cleaning

    SciTech Connect

    Bellamy, R.R.

    1994-12-31

    This report briefly describes the history of the use of high- efficiency particulate air filters for air cleaning at nuclear installations in the United States and discusses future uses of such filters.

  7. The Clean Air Game.

    ERIC Educational Resources Information Center

    Avalone-King, Deborah

    2000-01-01

    Introduces the Clean Air game which teaches about air quality and its vital importance for life. Introduces students to air pollutants, health of people and environment, and possible actions individuals can take to prevent air pollution. Includes directions for the game. (YDS)

  8. Air Cleaning Technologies

    PubMed Central

    2005-01-01

    Executive Summary Objective This health technology policy assessment will answer the following questions: When should in-room air cleaners be used? How effective are in-room air cleaners? Are in-room air cleaners that use combined HEPA and UVGI air cleaning technology more effective than those that use HEPA filtration alone? What is the Plasmacluster ion air purifier in the pandemic influenza preparation plan? The experience of severe acute respiratory syndrome (SARS) locally, nationally, and internationally underscored the importance of administrative, environmental, and personal protective infection control measures in health care facilities. In the aftermath of the SARS crisis, there was a need for a clearer understanding of Ontario’s capacity to manage suspected or confirmed cases of airborne infectious diseases. In so doing, the Walker Commission thought that more attention should be paid to the potential use of new technologies such as in-room air cleaning units. It recommended that the Medical Advisory Secretariat of the Ontario Ministry of Health and Long-Term Care evaluate the appropriate use and effectiveness of such new technologies. Accordingly, the Ontario Health Technology Advisory Committee asked the Medical Advisory Secretariat to review the literature on the effectiveness and utility of in-room air cleaners that use high-efficiency particle air (HEPA) filters and ultraviolet germicidal irradiation (UVGI) air cleaning technology. Additionally, the Ontario Health Technology Advisory Committee prioritized a request from the ministry’s Emergency Management Unit to investigate the possible role of the Plasmacluster ion air purifier manufactured by Sharp Electronics Corporation, in the pandemic influenza preparation plan. Clinical Need Airborne transmission of infectious diseases depends in part on the concentration of breathable infectious pathogens (germs) in room air. Infection control is achieved by a combination of administrative, engineering

  9. Clean air strategies study

    SciTech Connect

    Quartucy, G.C.; Chrisman, L.J.P. ); Nylander, J.H.; Keller, W.B. )

    1992-01-01

    This paper reports that San Diego Gas and Electric Company (SDG and E) is evaluating emissions control technologies suitable for retrofit to their utility boilers. This effort is being driven by actions undertaken by the San Diego Air Pollution Control District (SDAPCD) in response to the California Clean Air Act. These actions include the development of two Tactic Evaluations, and the preparation of proposed regulatory limits. Tactic Evaluations are proposed methods to achieve compliance with California ambient air quality standards. Emissions of concern include NO{sub x}, CO, ROG, PM and SO{sub 2}. Of these species, it appears that NO{sub x} is the emission species of primary concern.

  10. 13. EQUIPMENT USED IN CLEAN ROOM (102), INCLUDING ROYCO PARTICLE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. EQUIPMENT USED IN CLEAN ROOM (102), INCLUDING ROYCO PARTICLE COUNTER (LEFT) AND STEREOSCOPE FOR MANUAL PARTICLE COUNTING (RIGHT) - Vandenberg Air Force Base, Space Launch Complex 3, Vehicle Support Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  11. Clean Air Action

    NASA Astrophysics Data System (ADS)

    Carlowicz, Mike

    According to the Environmental Protection Agency, American electrical utility companies are ahead of schedule in reducing emissions of sulfur dioxide—a major contributor to acid rain—into the atmosphere. By the end of 1995, the 445 boilers with the highest emission levels had cut emissions from 10.9 million tons of SO2 to 5.3 million tons, 39% less emissions than were mandated by the Clean Air Act. Electric utilities account for more than 70% of sulfur dioxide emissions in the United States.

  12. Air-cleaning apparatus

    SciTech Connect

    Howard, A.G.

    1981-08-18

    An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces.

  13. The Clean Air Mercury Rule

    SciTech Connect

    Michael Rossler

    2005-07-01

    Coming into force on July 15, 2005, the US Clean Air Mercury Rule will use a market-based cap-and-trade approach under Section 111 of the Clean Air Act to reduce mercury emissions from the electric power sector. This article provides a comprehensive summary of the new rule. 14 refs., 2 tabs.

  14. Cleaning verification by air/water impingement

    NASA Technical Reports Server (NTRS)

    Jones, Lisa L.; Littlefield, Maria D.; Melton, Gregory S.; Caimi, Raoul E. B.; Thaxton, Eric A.

    1995-01-01

    This paper will discuss how the Kennedy Space Center intends to perform precision cleaning verification by Air/Water Impingement in lieu of chlorofluorocarbon-113 gravimetric nonvolatile residue analysis (NVR). Test results will be given that demonstrate the effectiveness of the Air/Water system. A brief discussion of the Total Carbon method via the use of a high temperature combustion analyzer will also be given. The necessary equipment for impingement will be shown along with other possible applications of this technology.

  15. Needed: Clean Air.

    ERIC Educational Resources Information Center

    Schneider, Gerald

    1979-01-01

    Provides information on air pollution for young readers. Discusses damage to substances and sickness from air pollution, air quality, and what to do in a pollution alert. Includes questions with answers, illustrations, and activities for the learner. (MA)

  16. 17th DOE nuclear air cleaning conference: proceedings. Volume 2

    SciTech Connect

    First, M.W.

    1983-02-01

    Volume 2 contains papers presented at the following sessions: adsorption; noble gas treatment; personnel education and training; filtration and filter testing; measurement and instrumentation; air cleaning equipment response to accident related stress; containment venting air cleaning; and an open end session. Twenty-eight papers were indexed separately for inclusion in the Energy Data Base. Ten papers had been entered earlier.

  17. Enhanced Clean Air Act enforcement

    SciTech Connect

    Faletto, J.S.

    1997-09-01

    The Clean Air Act Amendments of 1990 added new enforcement authorities which will change the way the US Environmental Protection Agency (EPA), the States and environmental groups litigate enforcement actions. EPA, the States and ordinary citizens now have at their disposal an extensive array of enforcement options to deter or penalize those who violate requirements of the Clean Air Act or State Implementation Plans (SIPs). These new enforcement authorities take on even greater significance for major sources covered by the Title V Operating Permit Program.

  18. 21 CFR 211.182 - Equipment cleaning and use log.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Equipment cleaning and use log. 211.182 Section... Reports § 211.182 Equipment cleaning and use log. A written record of major equipment cleaning... individual equipment logs that show the date, time, product, and lot number of each batch processed....

  19. Clean Air by Design.

    ERIC Educational Resources Information Center

    Crawford, Gary N.

    1995-01-01

    Planning new construction is an opportunity to recognize indoor environmental quality (IEQ) issues. Provides an overview of some common IEQ issues associated with construction projects. A building's heating, ventilating, and air-conditioning (HVAC) system is by far the single most common cause of IEQ problems and complaints. (MLF)

  20. The new Clean Air Act

    SciTech Connect

    Padmanabha, A.P. ); Olem, H. )

    1991-05-01

    This article is a title by title review of the new Clean Air Act and how it affects water quality and wastewater treatment. The bill provides for restoring and protecting lakes and rivers by reducing acid-rain-causing emissions and toxics from nonpoint-source runoff. Topics covered include urban smog, mobile sources, air toxics, acid rain, permits, ozone-depleting chemicals, enforcement, and the law's socio-economic impacts.

  1. The Clean Air Interstate Rule

    SciTech Connect

    Debra Jezouit; Frank Rambo

    2005-07-01

    On May 12, 2005, EPA promulgated the Clean Air Interstate Rule, which overhauls and expands the scope of air emissions trading programs in the eastern United States. The rule imposes statewide caps on emissions of nitrogen oxides and sulfur dioxide to be introduced in two phases, beginning in 2009. This article briefly explains the background leading up to the rule and summarizes its key findings and requirements. 2 refs., 1 fig., 1 tab.

  2. Clean Air Act. Revision 5

    SciTech Connect

    Not Available

    1994-02-15

    This Reference Book contains a current copy of the Clean Air Act, as amended, and those regulations that implement the statute and appear to be most relevant to DOE activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. This Reference Book has been completely revised and is current through February 15, 1994.

  3. 9 CFR 354.242 - Cleaning of equipment and utensils.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Cleaning of equipment and utensils... Sanitary Conditions and Precautions Against Contamination of Products § 354.242 Cleaning of equipment and... and in a sanitary condition and in good repair. (a) Pens shall be cleaned regularly and the...

  4. 9 CFR 354.242 - Cleaning of equipment and utensils.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Cleaning of equipment and utensils... Sanitary Conditions and Precautions Against Contamination of Products § 354.242 Cleaning of equipment and... and in a sanitary condition and in good repair. (a) Pens shall be cleaned regularly and the...

  5. 9 CFR 354.242 - Cleaning of equipment and utensils.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Cleaning of equipment and utensils... Sanitary Conditions and Precautions Against Contamination of Products § 354.242 Cleaning of equipment and... and in a sanitary condition and in good repair. (a) Pens shall be cleaned regularly and the...

  6. 9 CFR 354.242 - Cleaning of equipment and utensils.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Cleaning of equipment and utensils... Sanitary Conditions and Precautions Against Contamination of Products § 354.242 Cleaning of equipment and... and in a sanitary condition and in good repair. (a) Pens shall be cleaned regularly and the...

  7. 9 CFR 354.242 - Cleaning of equipment and utensils.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Cleaning of equipment and utensils... Sanitary Conditions and Precautions Against Contamination of Products § 354.242 Cleaning of equipment and... and in a sanitary condition and in good repair. (a) Pens shall be cleaned regularly and the...

  8. Cleaning and Sterilisation of Anaesthetic Equipment

    PubMed Central

    Juwarkar, Chitra Sanjeev

    2013-01-01

    The main purpose of this review article is to bring up what has been known (practiced) about decontamination, disinfection, and sterilisation of anaesthetic equipment. It also discusses how this evidence-based information on infection prevention and control impacts care of patient in routine anaesthesia practice. This review underscores the role played by us, anaesthetists in formulating guidelines, implementing the same, monitoring the outcome and training post-graduate trainees and coworkers in this regard. The article re-emphasises that certain guidelines when followed strictly will go a long way in reducing transmission of hospital acquired infection between patient and anaesthetist or between patients. Anaesthetists do not restrict their work to operating room but are involved in disaster management, interventional radiological procedures and in trauma care. They should ensure that the patients are cared for in clean and safe environment so as to reduce healthcare associated infections (HCAIs) simultaneously taking preventive measures against the various health hazards associated with clinical practice. They should ensure that the coworkers too adopt all the preventive measures while delivering their duties. For this review, we conducted literature searches in Medline (PubMed) and also searched for relevant abstracts and full texts of related articles that we came across. There is much to be learned from the western world where, health care organisations now have legal responsibility to implement changes in accordance with the newer technology to reduce health care associated infection. There is a need to develop evidence-based infection prevention and control programs and set national guidelines for disinfection and sterilisation of anaesthesia equipment which all the institutions should comply with. PMID:24249888

  9. Neutrally buoyant tracer in gas cleaning equipment: a case study

    NASA Astrophysics Data System (ADS)

    Peng, Weiming; Hoffmann, Alex C.; Dries, Huub W. A.; Regelink, Michiel; Foo, Kee-Khoon

    2005-12-01

    A generic problem when studying the gas flow in gas cleaning equipment is that any conventional tracer, whether solid particles or liquid droplets, is separated out in accordance with the purpose of the equipment. This makes it impossible, for instance, to visualize the core of the vortex in centrifugal gas cleaning equipment. This paper explores the use of a neutrally buoyant tracer. The tracer is soap bubbles filled with helium. The smaller density of the helium relative to the surrounding air is precisely compensated by the mass of the bubble film to create a neutrally buoyant tracer. The method is used to study the flow in a swirl-tube gas-solid separator, highlighting flow features that cannot be shown with, for instance, LDA. Results are shown as controlled exposure time photographs, where pathlines of the tracer show the flow pattern. The results are further clarified by high-time-resolution pressure measurements at the walls. The work shows that the vortex core can be directly visualized using this technique. The vortex core is observed to, under some conditions, bend to—and spin around—the wall of the separator. Under other conditions, the vortex core coincides with the separator axis, and extends to the bottom of the hopper under the swirl tube. Also the flow in the downstream tubing is studied. The possibilities for obtaining quantitative data for the gas velocity field are discussed, and a promising method for doing this is identified.

  10. The Value of Clean Air

    NASA Astrophysics Data System (ADS)

    Shindell, D. T.

    2014-12-01

    How can society place a value on clean air? I present a multi-impact economic valuation framework called the Social Cost of Atmospheric Release (SCAR) that extends the Social Cost of Carbon (SCC) used previously for carbon dioxide (CO2) to a broader range of pollutants and impacts. Values consistently incorporate health impacts of air quality along with climate damages. The latter include damages associated with aerosol-induced hydrologic cycle changes that lead to net climate benefits when reducing cooling aerosols. Evaluating a 1% reduction in current global emissions, benefits with a high discount rate are greatest for reductions of co-emitted products of incomplete combustion (PIC), followed by sulfur dioxide (SO2), nitrogen oxides (NOx) and then CO2, ammonia and methane. With a low discount rate, benefits are greatest for CO2 reductions, though the sum of SO2, PIC and methane is substantially larger. These results suggest that efforts to mitigate atmosphere-related environmental damages should target a broad set of emissions including CO2, methane and aerosol/ozone precursors. Illustrative calculations indicate environmental damages are 410-1100 billion yr-1 for current US electricity generation ( 19-46¢ per kWh for coal, 4-24¢ for gas) and 3.80 (-1.80/+2.10) per gallon of gasoline ($4.80 (-3.10/+3.50) per gallon for diesel). These results suggest that total atmosphere-related environmental damages plus generation costs are much greater for coal-fired power than other types of electricity generation, and that damages associated with gasoline vehicles substantially exceed those for electric vehicles.

  11. 40 CFR 63.1298 - Standards for slabstock flexible polyurethane foam production-HAP emissions from equipment cleaning.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... polyurethane foam production-HAP emissions from equipment cleaning. 63.1298 Section 63.1298 Protection of... Hazardous Air Pollutants for Flexible Polyurethane Foam Production § 63.1298 Standards for slabstock flexible polyurethane foam production—HAP emissions from equipment cleaning. Each owner or operator of...

  12. 40 CFR 63.1298 - Standards for slabstock flexible polyurethane foam production-HAP emissions from equipment cleaning.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... polyurethane foam production-HAP emissions from equipment cleaning. 63.1298 Section 63.1298 Protection of... Hazardous Air Pollutants for Flexible Polyurethane Foam Production § 63.1298 Standards for slabstock flexible polyurethane foam production—HAP emissions from equipment cleaning. Each owner or operator of...

  13. 40 CFR 63.5737 - How do I demonstrate compliance with the resin and gel coat application equipment cleaning...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the resin and gel coat application equipment cleaning standards? 63.5737 Section 63.5737 Protection of... Hazardous Air Pollutants for Boat Manufacturing Standards for Resin and Gel Coat Application Equipment Cleaning Operations § 63.5737 How do I demonstrate compliance with the resin and gel coat...

  14. A Citizen's Guide to Clean Air.

    ERIC Educational Resources Information Center

    Conservation Foundation, Washington, DC.

    This pamphlet is designed as a manual to help citizens participate in air quality control processes. The Clean Air Amendments of 1970 are explained, the first steps in determining a community's air pollution problems are outlined, the basic components of an implementation plan are specified, national and state standards of performance and…

  15. Cleanliness audit of clinical surfaces and equipment: who cleans what?

    PubMed

    Anderson, R E; Young, V; Stewart, M; Robertson, C; Dancer, S J

    2011-07-01

    Current guidelines recommend regular cleaning of clinical equipment. We monitored items on a surgical ward for predominant user, hand-touch frequency, cleaning responsibilities and measurement of organic soil. Equipment was assessed in triplicate against a cleanliness benchmark of 100 relative light units (RLU) using the Hygiena® ATP system. There were 44 items, of which 21 were cleaned by clinical support workers (CSWs), five by domestic staff; three by nurses, three by doctors, and 12 with no designated cleaning responsibility. Geometric mean RLUs ranged from 60 to 550/100 cm² for small items such as hand-gel containers, bed control, blood pressure cuff and clinical notes; with similar values of 80-540/100 cm² RLU for larger items such as electrocardiogram machine, defibrillator, trolleys and tables. Overall geometric mean was 249/100 cm² RLU for all surfaces, with 84% (37 of 44) items exceeding the 100RLU benchmark. Of 27 items cleaned by clinical staff, 24 (89%) failed the benchmark. Of 12 sites with no cleaning specification, 11 (92%) failed the benchmark. Three of seven 'clean' sites (<100/100 cm² RLU) were cleaned by domestic staff. Average log(10) RLU of surfaces cleaned by domestics were 64% lower compared with surfaces cleaned by CSWs (95% confidence interval: 35%, 80%; P=0.019). In conclusion, clinical equipment frequently demonstrates high levels of organic soil, whether or not items have assigned cleaning responsibility. These findings suggest that cleaning practices for clinical equipment may require review, along with education of staff with specific cleaning responsibilities.

  16. Clean Air Act Amendments of 2010

    THOMAS, 111th Congress

    Sen. Carper, Thomas R. [D-DE

    2010-02-04

    03/04/2010 Committee on Environment and Public Works Subcommittee on Clean Air and Nuclear Safety. Hearings held. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  17. Prototype air cleaning system for a firing range

    SciTech Connect

    Glissmeyer, J.A.; Mishima, J.; Bamberger, J.A.

    1985-01-01

    This report recommends air cleaning system components for the US Army Ballistics Research Laboratory's new large-caliber firing range, which is used for testing depleted uranium (DU) penetrators. The new air cleaning system has lower operating costs during the life of the system compared to that anticipated for the existing air cleaning system. The existing system consists of three banks of filters in series; the first two banks are prefilters and the last are high-efficiency particulate air (HEPA) filters. The principal disadvantage of the existing filters is that they are not cleanable and reusable. Pacific Northwest Laboratory focused the search for alternate air cleaning equipment on devices that do not employ liquids as part of the particle collection mechanism. Collected dry particles were assumed preferable to a liquid waste stream. The dry particle collection devices identified included electrostatic precipitators; inertial separators using turning vanes or cyclones; and several devices employing a filter medium such as baghouses, cartridge houses, cleanable filters, and noncleanable filters similar to those in the existing system. The economics of practical air cleaning systems employing the dry particle collection devices were evaluated in 294 different combinations. 7 references, 21 figures, 78 tables.

  18. Clean Air Slots Amid Atmospheric Pollution

    NASA Technical Reports Server (NTRS)

    Hobbs, Peter V.

    2002-01-01

    Layering in the Earth's atmosphere is most commonly seen where parts of the atmosphere resist the incursion of air parcels from above and below - for example, when there is an increase in temperature with height over a particular altitude range. Pollutants tend to accumulate underneath the resulting stable layers. which is why visibility often increases markedly above certain altitudes. Here we describe the occurrence of an opposite effect, in which stable layers generate a layer of remarkably clean air (we refer to these layers as clean-air 'slots') sandwiched between layers of polluted air. We have observed clean-air slots in various locations around the world, but they are particularly well defined and prevalent in southern Africa during the dry season August-September). This is because at this time in this region, stable layers are common and pollution from biomass burning is widespread.

  19. 76 FR 40728 - Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2011 Clean Air Excellence...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-11

    ... AGENCY Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2011 Clean Air Excellence... Air Excellence Awards. ] SUMMARY: EPA established the Clean Air Excellence Awards Program in February... progress in achieving clean air. This notice announces the competition for the Year 2011 program....

  20. 75 FR 35025 - Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2010 Clean Air Excellence...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-21

    ... AGENCY Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2010 Clean Air Excellence... Air Excellence Awards. SUMMARY: EPA established the Clean Air Excellence Awards Program in February... progress in achieving clean air. This notice announces the competition for the Year 2010 program....

  1. Impact of Air-Filter Condition on HVAC Equipment

    SciTech Connect

    Jung, L.

    1987-01-01

    An analysis was performed of changes in energy consumption caused by dirty filters for heating, ventilation, and air-conditioning systems during both heating and cooling cycles. Basic heat-transfer fundamentals and the vapor-compression refrigeration cycle for air conditioners were used. The energy cost savings between a dirty and a clean filter were small and were mainly offset by the filter cost. However, the consequences of deferring filter replacement could be very costly because of early equipment failures.

  2. 21 CFR 211.67 - Equipment cleaning and maintenance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Equipment cleaning and maintenance. 211.67 Section 211.67 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Equipment §...

  3. 21 CFR 211.67 - Equipment cleaning and maintenance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 4 2012-04-01 2012-04-01 false Equipment cleaning and maintenance. 211.67 Section 211.67 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Equipment §...

  4. 21 CFR 211.67 - Equipment cleaning and maintenance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 4 2014-04-01 2014-04-01 false Equipment cleaning and maintenance. 211.67 Section 211.67 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Equipment §...

  5. 21 CFR 211.67 - Equipment cleaning and maintenance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Equipment cleaning and maintenance. 211.67 Section 211.67 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Equipment §...

  6. 21 CFR 211.67 - Equipment cleaning and maintenance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Equipment cleaning and maintenance. 211.67 Section 211.67 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Equipment §...

  7. Clean Air. It's Up to You, Too.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC.

    Opportunities for citizen participation in federal environmental decisions relative to air pollution and its control are assessed in this booklet. The Environmental Protection Agency (EPA), as the federal agency charged with enforcement of the Clean Air Act, offers guidelines for responsible citizen action. Designed for groups already organized…

  8. Air cleaning and radon decay product mitigation

    SciTech Connect

    Hopke, P.K. ); Li, C.S. . John B. Pierce Foundation Lab.); Ramamurthi, M. )

    1990-01-01

    We evaluated air cleaning as a means to mitigate risks arising from exposure to indoor radon progeny in several single-family houses in the northeastern United States, using a new, automated, semi-continuous activity-weighted size distribution measurement system. Measurements included radon concentration, condensation nuclei count, and activity-weighted size distribution of radon decay products. Measurements were made with and without the air cleaning system operating. The influence of particles generated by various sources common to normal indoor activities on radon progeny behavior was evaluated. Aerosols were generated by running water in a shower, burning candles, smoking cigarettes, vacuuming, opening doors, and cooking. Both a filtration unit and an electrostatic precipitator were evaluated. Using a room model, the changes in attachment rates, average attachment diameters, and deposition rates of the unattached'' fraction with and without the air cleaning systems were calculated. The air cleaner typically reduced the radon progeny concentrations by 50 to 60%.

  9. Air cleaning and radon decay product mitigation

    SciTech Connect

    Hopke, P.K.; Li, C.S.; Ramamurthi, M.

    1990-12-31

    We evaluated air cleaning as a means to mitigate risks arising from exposure to indoor radon progeny in several single-family houses in the northeastern United States, using a new, automated, semi-continuous activity-weighted size distribution measurement system. Measurements included radon concentration, condensation nuclei count, and activity-weighted size distribution of radon decay products. Measurements were made with and without the air cleaning system operating. The influence of particles generated by various sources common to normal indoor activities on radon progeny behavior was evaluated. Aerosols were generated by running water in a shower, burning candles, smoking cigarettes, vacuuming, opening doors, and cooking. Both a filtration unit and an electrostatic precipitator were evaluated. Using a room model, the changes in attachment rates, average attachment diameters, and deposition rates of the ``unattached`` fraction with and without the air cleaning systems were calculated. The air cleaner typically reduced the radon progeny concentrations by 50 to 60%.

  10. Stakeholder perspectives on the Clean Air Interstate and the Clean Air Mercury Rules

    SciTech Connect

    C.V. Mathai; Jeffrey Holmstead; Michael Shore; Skiles Boyd; Vicky Sullivan; Dan Weiss; John Kinsman; Steve Lomax; Michael Rossler; David Steele; Greg Schaefer; Felice Stadler; David Foerter; William Becker

    2005-08-01

    In a follow-up to last month's detailed overviews of the Clean Air Interstate Rule (CAIR) and the Clean Air Mercury Rule (CAMR), this month EM presents perspectives on the two rules from representatives of a range of stakeholders, including EPA, the states, the regulated community, and the environmental community. Titles of the perspectives are: A Multipollutant Approach to Emissions Reductions; Clean Air Lessons from the Myth of Sisyphus; Reactions to EPA's Clean Air Interstate and Clean Air Mercury Rules; The Case for Coal Rank Subcategorization to Regulate Mercury Emissions; EPA's Mercury Rule: The Latest Delay Tactic; EPA's Mercury Rule: With Technology Today, We Can Do Better; STAPPA/ALAPCO's Perspectives on CAMR and CAIR. 16 refs.

  11. PERFORMANCE TESTING OF AIR CLEANING PRODUCTS

    EPA Science Inventory

    The paper discuses the application of the Environmental Technology Verification (ETV) Program for products that clean ventilation air to the problem of protecting buildings from chemical and biological attack. This program is funded by the U.S. Environmental Protection Agency und...

  12. Senate begins clean air legislation debate

    SciTech Connect

    Yates, M.

    1990-03-01

    This article reports on Senate debate on the Clean Air Act Amendments of 1989. Topics include acid rain provisions, administration objections, costs of the bill including disparity of costs in different regions and cost-sharing proposals, and the effects the current energy policy will have on the bill. Presidential, Senate, and subcommittee views on the bill are presented.

  13. 24. Left side view of equipment used to clean and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. Left side view of equipment used to clean and wash sand prior to reuse on the sand filter bed. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  14. 23. Right side view of equipment used to clean and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. Right side view of equipment used to clean and wash sand prior to reuse on the sand filter bed. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  15. 21 CFR 211.182 - Equipment cleaning and use log.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 4 2014-04-01 2014-04-01 false Equipment cleaning and use log. 211.182 Section 211.182 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Records...

  16. 21 CFR 211.182 - Equipment cleaning and use log.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Equipment cleaning and use log. 211.182 Section 211.182 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Records...

  17. 21 CFR 211.182 - Equipment cleaning and use log.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 4 2012-04-01 2012-04-01 false Equipment cleaning and use log. 211.182 Section 211.182 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Records...

  18. 21 CFR 211.182 - Equipment cleaning and use log.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Equipment cleaning and use log. 211.182 Section 211.182 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Records...

  19. 76 FR 66717 - Notification of a Public Teleconference of the Clean Air Scientific Advisory Committee Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-27

    ... AGENCY Notification of a Public Teleconference of the Clean Air Scientific Advisory Committee Air Monitoring and Methods Subcommittee AGENCY: Environmental Protection Agency (EPA). ACTION: Notice. SUMMARY... announces a public teleconference of the Clean Air Scientific Advisory Committee (CASAC) Air Monitoring...

  20. EPA`s clean air power initiative

    SciTech Connect

    Critchfield, L.R.

    1997-12-31

    The Clean Air Power Initiative (CAPI) is a multi-stakeholder project intended to improve air pollution control efforts involving the power generating industry. This paper documents the progress made in the first year of the initiative, which included a number of meetings with interested stakeholders and development and analysis of alternative approaches for more efficient and effective pollution control. The project`s goal is to develop an integrated regulatory strategy or three major pollutants emitted from electric power generators; namely, sulfur dioxide, nitrogen oxides, and, potentially, mercury. Major reductions in these pollutants are expected to be needed to reduce the detrimental health effects of ground-level ozone, fine particles, and hazardous air pollutants and reduce the environmental effects of acidification, eutrophication, ecosystem, crop, and materials damage, and regional haze. The Clean Air Power Initiative has considered, where feasible, new approaches to pollution control that recognize the long-range transport of many air pollutants and the economic benefits of emissions trading. The project was initiated by EPA`s Assistant Administrator for Air and Radiation in 1995. As individual companies develop and implement strategies to participate in more competitive power markets, they could benefit from greater certainty in being able to plan for and reduce costs of future environmental regulations. The EPA is interested in reinventing its regulatory approach to reduce the number, administrative complexity, and cost of its requirements while improving the likelihood of achieving environmental results.

  1. 14 CFR 1260.34 - Clean air and water.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 5 2013-01-01 2013-01-01 false Clean air and water. 1260.34 Section 1260... AGREEMENTS General Provisions § 1260.34 Clean air and water. Clean Air and Water October 2000 (Applicable... the Clean Air Act (42 U.S.C. 1857c-8(c)(1) or the Federal Water Pollution Control Act (33 U.S.C....

  2. 14 CFR 1260.34 - Clean air and water.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Clean air and water. 1260.34 Section 1260... AGREEMENTS General Provisions § 1260.34 Clean air and water. Clean Air and Water October 2000 (Applicable... the Clean Air Act (42 U.S.C. 1857c-8(c)(1) or the Federal Water Pollution Control Act (33 U.S.C....

  3. 14 CFR § 1260.34 - Clean air and water.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 5 2014-01-01 2014-01-01 false Clean air and water. § 1260.34 Section Â... AGREEMENTS General Provisions § 1260.34 Clean air and water. Clean Air and Water October 2000 (Applicable... the Clean Air Act (42 U.S.C. 1857c-8(c)(1) or the Federal Water Pollution Control Act (33 U.S.C....

  4. 14 CFR 1260.34 - Clean air and water.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 5 2012-01-01 2012-01-01 false Clean air and water. 1260.34 Section 1260... AGREEMENTS General Provisions § 1260.34 Clean air and water. Clean Air and Water October 2000 (Applicable... the Clean Air Act (42 U.S.C. 1857c-8(c)(1) or the Federal Water Pollution Control Act (33 U.S.C....

  5. 77 FR 16548 - Clean Air Act Advisory Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-21

    ... AGENCY Clean Air Act Advisory Committee AGENCY: Environmental Protection Agency (EPA). ACTION: Request for Nominations to the Clean Air Act Advisory Committee. SUMMARY: The U.S. Environmental Protection... appointment to its Clean Air Act Advisory Committee (CAAAC). Applications are due by May 1, 2012 and...

  6. Proposed Clean Air Act reform draws fire

    NASA Astrophysics Data System (ADS)

    Showstack, Randy

    A Congressional hearing on the accomplishments of the U.S. Clean Air Act and subsequent amendments turned into a squabble about whether Bush administration efforts to reform the act would improve or undermine air quality regulations.At the 1 May hearing of the House of Representatives' Subcommittee on Energy and Air Quality, a key sticking point concerned whether an emissions "cap-and-trade" program, which was proposed as part of President George W. Bush's 14 February Clear Skies initiative, would effectively meet air quality standards. The program would provide market-based incentives to reduce emissions of sulfur dioxide, nitrogen oxides, and mercury. Another point of contention was whether such a program would make some current regulations, including new source review of upgraded utility plants, redundant and unnecessary.

  7. Chapter A3. Cleaning of Equipment for Water Sampling

    USGS Publications Warehouse

    Wilde, Franceska D.; Radtke, Dean B.; Gibs, Jacob; Iwatsubo, Rick T.

    1998-01-01

    The National Field Manual for the Collection of Water-Quality Data (National Field Manual) describes protocols and provides guidelines for U.S. Geological Survey (USGS) personnel who collect data used to assess the quality of the Nation's surface-water and ground-water resources. Chapter A3 describes procedures for cleaning the equipment used to collect and process samples of surface water and ground water and procedures for assessing the efficacy of the equipment-cleaning process. This chapter is designed for use with the other chapters of this field manual. Each chapter of the National Field Manual is published separately and revised periodically. Newly published and revised chapters will be posted on the USGS page 'National Field Manual for the Collection of Water-Quality Data.' The URL for this page is http://pubs.water.usgs.gov/twri9A/ (accessed September 20, 2004).

  8. [Design, equipment, and management for air conditioning in operating room].

    PubMed

    Fuji, Kumiko; Mizuno, Ju

    2011-11-01

    In order to maintain air cleanliness in the operating room (OR) permanently, air exchange rate in the OR should be more than 15 times x hr(-1), the laminar air flow should be kept, and the numbers of the persons in the OR and the numbers of opening and closing OR door should be limited. High efficiency particulate air (HEPA) filter is effective in collection and removal of airborne microbes, and is used in the biological clean room. We need to design, equip, and manage the OR environment according to Guideline for Design and Operation of Hospital HVAC Systems HEAS-02-2004 established by Healthcare Engineering Association of Japan and Guideline for Prevention of Surgical Site Infection (SSI) established by the Center for Disease Control and Prevention (CDC) in the USA. PMID:22175178

  9. Clean fuel vehicles: The air pollution solution

    SciTech Connect

    Meotti, M.P.

    1995-11-01

    Clean fuels for cars and trucks can do more for air quality, and do it sooner, than any other alternative on the drawing boards today. In much of the country, vehicles are the single biggest cause of air pollution. It`s not the industrial smoke stacks, but the tail pipes on cars that foul the air. Ninety percent of the carbon monoxide, 50% of the volatile organic compounds, and 40% of the ozone in metropolitan areas come from motor vehicles. Many state and local government officials are pursuing vehicle emission inspection, high occupancy vehicle lanes, and carpooling programs to reduce auto pollution. These efforts are valuable and should be continued. But clean fuels can quickly reduce auto emissions at a much lower cost. Alternative fuel vehicles produce fewer emissions, are much less dependent on foreign sources, and have the potential to create new jobs. One alternative fuel, natural gas, emits no particulates, 90% less carbon monoxide, and 85% fewer of the gases that form ozone.

  10. 75 FR 73026 - Approval and Promulgation of Air Quality Implementation Plans; Indiana; Clean Air Interstate Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-29

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Indiana; Clean Air... June 29, 2009, to revise the Indiana State Implementation Plan (SIP) under the Clean Air Act (CAA). The... Clean Air Interstate Rule (CAIR), for which EPA granted limited approval as an abbreviated SIP...

  11. Blue skies, green politics: The Clean Air Act of 1990

    SciTech Connect

    Bryner, G.C.

    1995-10-01

    This book presents a discussion framework for the Clean Air Act Amendments of 1990. The author focuses on both an analysis of the problem of air pollution and an examination of the politics that went in to crafting the Clean Air Act Amendments. The book is intended for those not familiar with the problem.

  12. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  13. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  14. 14 CFR 1260.34 - Clean air and water.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 5 2011-01-01 2010-01-01 true Clean air and water. 1260.34 Section 1260.34... Provisions § 1260.34 Clean air and water. Clean Air and Water October 2000 (Applicable only if the award... (42 U.S.C. 1857c-8(c)(1) or the Federal Water Pollution Control Act (33 U.S.C. 1319(c)), and is...

  15. Clean Air Act: Senate mulls revision bill

    SciTech Connect

    Fairley, P.

    1995-12-13

    Senator Lauch Faircloth (R., NC) has circulated a draft summary of possible revisions of the Clean Air Act (CAA). Chemical industry sources say the proposal would provide some regulatory relief but fear that supporting Faircloth could jeopardize their relationship with EPA. Faircloth`s proposal addresses various controversial aspect of CAA`s Title V permit program including the monitoring and permit modification provisions. The proposal would also define a facility`s {open_quotes}potential to emit,{close_quotes} upon which Title V permits are based. In the past year EPA has substantially revised its Title V program to address complaints from industry, the states, and Congress that the monitoring and modification provisions were too burdensome.

  16. IMPROVED EQUIPMENT CLEANING IN COATED AND LAMINATED SUBSTRATE MANUFACTURING FACILITIES (PHASE I)

    EPA Science Inventory

    The report gives results of a Phase I study to characterize current equipment cleaning practices in the coated and laminated substrate manufacturing industry, to identify alternative cleaning technologies, and to identify demonstrable technologies and estimate their emissions imp...

  17. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  18. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  19. 78 FR 17229 - Notice of Lodging of Proposed Consent Decree Amendment Under the Clean Air Act; the Clean Water...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-20

    ... of Lodging of Proposed Consent Decree Amendment Under the Clean Air Act; the Clean Water Act; the Resource Conservation and Recovery Act; the Missouri Air Conservation Law; the Missouri Clean Water Law and..., the Clean Water Act, the Missouri Clean Water Law, the Resource Conservation and Recovery Act, and...

  20. 75 FR 8994 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-26

    ... that on February 16, 2010, a proposed Consent Decree in United States v. Belson Steel Center Scrap, Inc... penalty against Belson Steel Center Scrap, Inc. (``Belson''), pursuant to section 113(b) of the Clean Air... (``CFC'') removal equipment, (2) have properly trained operators evacuate CFCs from scrap...

  1. 77 FR 53235 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-31

    ..., a proposed consent decree in United States of America and Mecklenburg County v. Emerald Carolina... penalties and injunctive relief for alleged violations of Clean Air Act regulations at Emerald Carolina... applicable to certain equipment at the plant. The proposed consent decree requires Emerald Carolina...

  2. Air cleaning issues with contaminated sites

    SciTech Connect

    Bellamy, R.R.

    1997-08-01

    The US Nuclear Regulatory Commission has developed a list of contaminated sites that warrant special USNRC attention because they pose unique or complex decommissioning issues. This list of radiologically contaminated sites is termed the Site Decommissioning Management Plan (SDMP), and was first issued in 1990. A site is placed on the SDMP list if it has; (1) Problems with the viability of the responsible organization (e.g., the licensee for the site is unable or unwilling to pay for the decommissioning); (2) Large amounts of soil contamination or unused settling ponds or burial grounds that may make the waste difficult to dispose of; (3) The long-term presence of contaminated, unused buildings; (4) A previously terminated license; or (5) Contaminated or potential contamination of the ground water from on-site wastes. In deciding whether to add a site to the SDMP list, the NRC also considers the projected length of time for decommissioning and the willingness of the responsible organization to complete the decommissioning in a timely manner. Since the list was established, 9 sites have been removed from the list, and the current SDMP list contains 47 sites in 11 states. The USNRC annually publishes NUREG-1444, {open_quotes}Site Decommissioning Management Plan{close_quotes}, which updates the status of each site. This paper will discuss the philosophical goals of the SDMP, then will concentrate on the regulatory requirements associated with air cleaning issues at the SDMP sites during characterization and remediation. Both effluent and worker protection issues will be discussed. For effluents, the source terms at sites will be characterized, and measurement techniques will be presented. Off-site dose impacts will be included. For worker protection issues, air sampling analyses will be presented in order to show how the workers are adequately protected and their doses measured to satisfy regulatory criteria during decontamination operations. 1 tab.

  3. Identification of Candidate Clean Air Corridors for the Colorado Plateau.

    PubMed

    Gratn, M C; Pitchford, M L; Ashbaugh, L

    1996-05-01

    The U.S. Clean Air Act, amended in 1990, mandated the establishment of the Grand Canyon Visibility Transport Commission (GCVTC). The commission is required to submit a report to the U.S. Environmental Protection Agency addressing visibility issues in the region, including "the establishment of clean air corridors, in which additional restrictions on increases in emissions may be appropriate to protect visibility in affected Class I areas." This paper presents a methodology to identify candidate geographic areas for consideration for Clean Air Corridor (CAC) status for Colorado Plateau Class I areas. The methodology uses thousands of model determined trajectories over a five year period (1988 to 1992) to indicate the paths taken by air that arrives during clean air conditions at Class I areas. These clean air back-trajectories identify upwind areas where pollution emissions could jeopardize currently pristine visibility. Using this methodology, six candidate areas are identified, ranging in size from 75,000 to 506,000 square miles, and permitting varying levels of visibility protection for clean air days at Grand Canyon, Canyonlands, and Petrified Forest National Parks. Assuming effective emissions management of the CAC, the larger the CAC, the greater the visibility protection during clean air conditions.

  4. Clean Cities Guide to Alternative Fuel Commercial Lawn Equipment (Brochure)

    SciTech Connect

    Not Available

    2011-10-01

    Guide explains the different types of alternative fuel commercial mowers and lists the makes and models of the ones available on the market. Turf grass is a fixture of the American landscape and the American economy. It is the nation's largest irrigated crop, covering more than 40 million acres. Legions of lawnmowers care for this expanse during the growing season-up to year-round in the warmest climates. The annual economic impact of the U.S. turf grass industry has been estimated at more than $62 billion. Lawn mowing also contributes to the nation's petroleum consumption and pollutant emissions. Mowers consume 1.2 billion gallons of gasoline annually, about 1% of U.S. motor gasoline consumption. Commercial mowing accounts for about 35% of this total and is the highest-intensity use. Large property owners and mowing companies cut lawns, sports fields, golf courses, parks, roadsides, and other grassy areas for 7 hours per day and consume 900 to 2,000 gallons of fuel annually depending on climate and length of the growing season. In addition to gasoline, commercial mowing consumes more than 100 million gallons of diesel annually. Alternative fuel mowers are one way to reduce the energy and environmental impacts of commercial lawn mowing. They can reduce petroleum use and emissions compared with gasoline- and diesel-fueled mowers. They may also save on fuel and maintenance costs, extend mower life, reduce fuel spillage and fuel theft, and promote a 'green' image. And on ozone alert days, alternative fuel mowers may not be subject to the operational restrictions that gasoline mowers must abide by. To help inform the commercial mowing industry about product options and potential benefits, Clean Cities produced this guide to alternative fuel commercial lawn equipment. Although the guide's focus is on original equipment manufacturer (OEM) mowers, some mowers can be converted to run on alternative fuels. For more information about propane conversions. This guide may be

  5. 40 CFR 61.152 - Air-cleaning.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Air-cleaning. 61.152 Section 61.152 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Asbestos § 61.152...

  6. Some impacts of the 1990 Clean Air Act and state clean-air regulations on the fertilizer industry

    SciTech Connect

    Breed, C.E.; Kerns, O.S.

    1992-12-31

    The Clean Air Act amendments of 1990 will intensify national efforts to reduce air pollution. They will have major impacts on governmental agencies and on industrial and commercial facilities throughout the country. As with other industries, it is essential for fertilizer dealers and producers to understand how these changes to the Clean Air Act can significantly change the way they do business. This paper is proffered as an overview of ways in which the 1990 amendments to the Clean Air Act may impact the fertilizer industry. The nonattainment, toxics, and permit provisions of the amended act will be three areas of particular concern to the fertilizer industry. Implementation of the new regulatory requirements of this legislation promises to be a long and onerous process for all concerned. However, it appears that state and local regulations may have a much more profound impact on the fertilizer industry than the new Clean Air Act.

  7. Some impacts of the 1990 Clean Air Act and state clean-air regulations on the fertilizer industry

    SciTech Connect

    Breed, C.E.; Kerns, O.S.

    1992-12-01

    The Clean Air Act amendments of 1990 will intensify national efforts to reduce air pollution. They will have major impacts an governmental agencies and on industrial and commercial facilities throughout the country. As with other industries, it is essential for fertilizer dealers and producers to understand how these changes to the Clean Air Act can significantly change the way they do business. This paper is proffered as an overview of ways in which the 1990 amendments to the Clean Air Act may impact the fertilizer industry. The nonattainment, toxics, and permit provisions of the amended act will be three areas of particular concern to the fertilizer industry. Implementation of the new regulatory requirements of this legislation promises to be a long and onerous process for all concerned. However, it appears that state and local regulations may have a much more profound impact on the fertilizer industry than the new Clean Air Act.

  8. PHASE I PILOT AIR CONVEYANCE SYSTEM DESIGN, CLEANING, AND CHARACTERIZATION

    EPA Science Inventory

    The report gives results of a project to develop and refine surface and airborne contamination
    measurement techniques that can be used to evaluate air conveyance system (ACS) cleaning.
    (NOTE: ACS cleaning is advertized to homeowners as a service having a number of benefits...

  9. 53. VIEW OF ROCK FOUNDATIONS AIR CLEANED FOR MONOLITHS 1722, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    53. VIEW OF ROCK FOUNDATIONS AIR CLEANED FOR MONOLITHS 17-22, INTERMEDIATE WALL, LOOKING NORTH Photograph No. 12840. September 10, 1948 - Upper Mississippi River 9-Foot Channel Project, Lock & Dam 27, Granite City, Madison County, IL

  10. 46 CFR 154.1852 - Air breathing equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Air breathing equipment. 154.1852 Section 154.1852... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1852 Air breathing equipment. (a) The master shall ensure that a licensed officer inspects the compressed air...

  11. 46 CFR 154.1852 - Air breathing equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Air breathing equipment. 154.1852 Section 154.1852... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1852 Air breathing equipment. (a) The master shall ensure that a licensed officer inspects the compressed air...

  12. 46 CFR 154.1852 - Air breathing equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Air breathing equipment. 154.1852 Section 154.1852... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1852 Air breathing equipment. (a) The master shall ensure that a licensed officer inspects the compressed air...

  13. 46 CFR 154.1852 - Air breathing equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Air breathing equipment. 154.1852 Section 154.1852... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1852 Air breathing equipment. (a) The master shall ensure that a licensed officer inspects the compressed air...

  14. NASA Principal Center for Review of Clean Air Act Regulations

    NASA Technical Reports Server (NTRS)

    Clark-Ingram, Marceia; Munafo, Paul M. (Technical Monitor)

    2002-01-01

    The Clean Air Act (CAA) regulations have greatly impacted materials and processes utilized in the manufacture of aerospace hardware. Code JE/ NASA's Environmental Management Division at NASA Headquarters recognized the need for a formal, Agency-wide review process of CAA regulations. Marshall Space Flight Center (MSFC) was selected as the 'Principal Center for Review of Clean Air Act Regulations'. This presentation describes the centralized support provided by MSFC for the management and leadership of NASA's CAA regulation review process.

  15. 78 FR 70960 - Notice of Lodging of Consent Decree Under the Clean Air Act, Clean Water Act, and the Resource...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-27

    ... of Lodging of Consent Decree Under the Clean Air Act, Clean Water Act, and the Resource Conservation... the United States and the State of Illinois under the Clean Air Act, the Clean Water Act, the Resource Conservation and Recovery Act, and relevant state law at facilities formerly owned by PolyOne...

  16. 75 FR 11560 - Notice of Lodging of Consent Decree Under the Clean Water Act and Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-11

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Water Act and Clean Air Act Notice is hereby given that... violations of the Clean Water Act, 33 U.S.C. 1251 et seq., and the Clean Air Act, 42 U.S.C. 7401 et seq....

  17. 75 FR 10503 - Notice of Lodging of Consent Decree Under the Clean Air Act, the Clean Water Act, the Emergency...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-08

    ... of Lodging of Consent Decree Under the Clean Air Act, the Clean Water Act, the Emergency Planning and Community Right-To-Know Act, and the Comprehensive Environmental Response, Compensation, and Liability Act... Clean Air Act, 42 U.S.C. 7401-7671q, the Clean Water Act, 33 U.S.C. 1251-1387, the Emergency...

  18. 78 FR 15376 - Notice of Lodging of Proposed Consent Decree Amendment Under the Clean Air Act; the Clean Water...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-11

    ... of Lodging of Proposed Consent Decree Amendment Under the Clean Air Act; the Clean Water Act; the Resource Conservation and Recovery Act; the Emergency Planning and Community Right-To-Know Act; and the... Clean Air Act, the Resource Conservation and Recovery Act, the Clean Water Act, the Emergency...

  19. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy

    SciTech Connect

    Sidheswaran, Meera; Destaillats, Hugo; Sullivan, Douglas P.; Fisk, William J.

    2010-10-27

    Approximately ten percent of the energy consumed in U.S. commercial buildings is used by HVAC systems to condition outdoor ventilation air. Reducing ventilation rates would be a simple and broadly-applicable energy retrofit option, if practical counter measures were available that maintained acceptable concentrations of indoor-generated air pollutants. The two general categories of countermeasures are: 1) indoor pollutant source control, and 2) air cleaning. Although pollutant source control should be used to the degree possible, source control is complicated by the large number and changing nature of indoor pollutant sources. Particle air cleaning is already routinely applied in commercial buildings. Previous calculations indicate that particle filtration consumes only 10percent to 25percent of the energy that would otherwise be required to achieve an equivalent amount of particle removal with ventilation. If cost-effective air cleaning technologies for volatile organic compounds (VOCs) were also available, outdoor air ventilation rates could be reduced substantially and broadly in the commercial building stock to save energy. The research carried out in this project focuses on developing novel VOC air cleaning technologies needed to enable energy-saving reductions in ventilation rates. The minimum required VOC removal efficiency to counteract a 50percent reduction in ventilation rate for air cleaning systems installed in the HVAC supply airstream is modest (generally 20percent or less).

  20. OFFICE EQUIPMENT: DESIGN, INDOOR AIR EMISSIONS, AND POLLUTION PREVENTION OPPORTUNITIES

    EPA Science Inventory

    The report summarizes available information on office equipment design; indoor air emissions of organics, ozone, and particulates from office equipment; and pollution prevention approaches for reducing these emissions. Since much of the existing emissions data from office equipme...

  1. Food-Growing, Air- And Water-Cleaning Module

    NASA Technical Reports Server (NTRS)

    Sauer, R. L.; Scheld, H. W.; Mafnuson, J. W.

    1988-01-01

    Apparatus produces fresh vegetables and removes pollutants from air. Hydroponic apparatus performs dual function of growing fresh vegetables and purifying air and water. Leafy vegetables rooted in granular growth medium grow in light of fluorescent lamps. Air flowing over leaves supplies carbon dioxide and receives fresh oxygen from them. Adaptable to production of food and cleaning of air and water in closed environments as in underwater research stations and submarines.

  2. 75 FR 34673 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-18

    ... Pollutants: Air Emission Standards for Halogenated Solvent Cleaning Machines: State of Rhode Island... applies to organic solvent cleaning machines in Rhode Island, except for continuous web cleaning machines... General Definitions Rule in place of the Halogenated Solvent NESHAP for organic solvent cleaning...

  3. Development method of the motor winding's ultrasonic cleaning equipment

    NASA Astrophysics Data System (ADS)

    Jiang, Yingzhan; Wang, Caiyuan; Ao, Chenyang; Zhang, Haipeng

    2013-03-01

    The complicate question's solution of motor winding cleaning need new technologies such as ultrasonic cleaning. The mechanism of problems that the insulation level of the motor winding would be degraded with time and the motor winding would resumed tide soon after processing were analyzed. The ultrasonic cleaning method was studies and one ultrasonic cleaning device was designed. Its safety was verified by the destructive experiment. The test show that this device can clear away the depositional dirt in the winding thoroughly, which provides a new idea and method to ensure its insulation level and realize its safe and reliable operation.

  4. Clean Air Slots Amid Atmospheric Pollution

    NASA Technical Reports Server (NTRS)

    Hobbs, Peter V.

    2002-01-01

    This article investigates the mechanism for those layers in the atmosphere that are free of air borne pollution even though the air above and below them carry pollutants. Atmospheric subsidence is posed as a mechanism for this phenomenon.

  5. 75 FR 4069 - Science Advisory Board Staff Office; Notification of a Clean Air Scientific Advisory Committee...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-26

    ... Clean Air Scientific Advisory Committee (CASAC) Ambient Air Monitoring & Methods Subcommittee (AAMMS or... AGENCY Science Advisory Board Staff Office; Notification of a Clean Air Scientific Advisory Committee (CASAC); Ambient Air Methods and Monitoring Subcommittee (AAMMS); Meeting and Public...

  6. 45. Communication equipment room, cable air dryer on left, motorola ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. Communication equipment room, cable air dryer on left, motorola base station (vhf) at right, looking southwest - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  7. 46. Communication equipment room, shock isolator air compressor at right, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. Communication equipment room, shock isolator air compressor at right, looking northeast - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  8. 40 CFR 63.5737 - How do I demonstrate compliance with the resin and gel coat application equipment cleaning...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equipment cleaning standards? (a) Determine and record the organic HAP content of the cleaning solvents... recycle cleaning solvents on site, you may use documentation from the solvent manufacturer or supplier...

  9. 40 CFR 63.5737 - How do I demonstrate compliance with the resin and gel coat application equipment cleaning...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equipment cleaning standards? (a) Determine and record the organic HAP content of the cleaning solvents... recycle cleaning solvents on site, you may use documentation from the solvent manufacturer or supplier...

  10. Clean Air Slots Amid Dense Atmospheric Pollution in Southern Africa

    NASA Technical Reports Server (NTRS)

    Hobbs, Peter V.

    2003-01-01

    During the flights of the University of Washington's Convair-580 in the Southern African Regional Science Initiative (SAFARI 2000) in southern Africa, a phenomenon was observed that has not been reported previously. This was the occurrence of thin layers of remarkably clean air, sandwiched between heavily polluted air, which persisted for many hours during the day. Photographs are shown of these clean air slots (CAS), and particle concentrations and light scattering coefficients in and around such slot are presented. An explanation is proposed for the propensity of CAS to form in southern Africa during the dry season.

  11. Clean air amendments put big burden on refinery planners

    SciTech Connect

    Scherr, R.C.; Smalley, G.A. Jr.; Norman, M.E. )

    1991-06-10

    The Clean Air Act Amendments of 1990 will not only require the production of reformulated gasoline but also have significant impact on other refinery-related construction. This must be considered when developing sound planning strategy. The three titles of the Clean Air Act Amendments that will have the greatest effect on refining are: Title I: Nonattainment; Title III: Air toxics; Title V: Permitting. To understand the ramifications of these amendments, it is necessary to review the interactions of new requirements with the permitting and construction schedule shown.

  12. 40 CFR 49.3 - General Tribal Clean Air Act authority.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false General Tribal Clean Air Act authority... ASSISTANCE TRIBAL CLEAN AIR ACT AUTHORITY Tribal Authority § 49.3 General Tribal Clean Air Act authority... respect to all provisions of the Clean Air Act and implementing regulations, except for those...

  13. 40 CFR 49.10 - EPA review of State Clean Air Act programs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false EPA review of State Clean Air Act... FEDERAL ASSISTANCE TRIBAL CLEAN AIR ACT AUTHORITY Tribal Authority § 49.10 EPA review of State Clean Air Act programs. A State Clean Air Act program submittal shall not be disapproved because of failure...

  14. A clean air continuous flow propulsion facility

    NASA Technical Reports Server (NTRS)

    Krauss, R. H.; Mcdaniel, J. C., Jr.

    1992-01-01

    Consideration is given to a contaminant-free, high enthalpy, continuous flow facility designed to obtain detailed code validation measurements of high speed combustion. The facility encompasses uncontaminated air temperature control to within 5 K, fuel temperature control to 2 K, a ceramic flow straightener, drying of inlet air, and steady state continuous operation. The air heating method provides potential for independent control of contaminant level by injection, mixing, and heating upstream. Particular attention is given to extension of current capability of 1250 K total air temperature, which simulates Scramjet enthalpy at Mach 5.

  15. IMPROVED EQUIPMENT CLEANING IN COATED AND LAMINATED SUBSTRATE MANUFACTURING FACILITIES (PHASE II)

    EPA Science Inventory

    The report discusses EPA efforts to identify, demonstrate, and publish pollution prevention information and opportunities for equipment cleaning for the coated and laminated substrate manufacturing industry. It summarizes initial data collected and summarized during industry obse...

  16. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  17. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  18. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  19. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  20. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  1. Effect of dirty-hold time on cleaning process of pharmaceutical equipment.

    PubMed

    Patera, Jan; Stípková, Gabriela; Zámostný, Petr; Bělohlav, Zdeněk; Vltavský, Zdeněk

    2013-02-01

    The work was aimed at the evaluation of a cleanliness of pharmaceutical equipments after the end of the production and subsequent cleaning process. The influence of a dirty-hold time, a time interval between the end of the production period and the beginning of the cleaning process on its efficiency and the cleanliness of the equipment has been studied. The evaluation was performed for commercial tablet antihypertensive formulation with API losartan potassium. Sampling was carried out by a wet-swabbing method from the equipments and consequently obtained samples were analytically evaluated using HPLC. In the production of the concerned pharmaceutical, it has been found that the cleaning process is properly designed and validated. Despite the concentration of losartan in swabs from the equipment was in all cases within the limits of acceptance criteria, the effect of the dirty-hold time was proved. In the equipments with long hold-time period, the monitored substance was found in substantially higher concentrations.

  2. Measurement of formaldehyde in clean air

    SciTech Connect

    Neitzert, V.; Seiler, W.

    1981-01-01

    A method for the measurement of small amounts of formaldehyde in air has been developed. The method is based on the derivatization of HCHO with 2.4-Denetrophenylhydragine, forming 2.4-Dentrophylhydragine, measured with GC-ECD-technique. HCHO is preconcentrated using a cryogenic sampling technique. The detection limit is 0.05 ppbv for a sampling volume of 200 liter. The method has been applied for measurements in continental and marine air masses showing HCHO mixing ratios of 0.4--5.0 ppbv and 0.2--1.0 ppbv, respectively. HCHO mixing ratios show diurnal variations with maximum values during the early afternoon and minimum values during the early morning. In continental air, HCHO mixing ratios are positively correlated with CO and SO/sub 2/, indicating anthropogenic HCHO sources which are estimated to be 6--11 x 10/sup 12/g/year/sup -1/ on a global scale.

  3. New challenges to air/gas cleaning systems

    SciTech Connect

    Kovach, J.L.

    1997-08-01

    This paper discusses the need for changes in the design and manufacturing of air and gas cleaning systems to meet waste management and site remediation requirements. Current design and manufacturing practices are primarily directed toward evaluating operational problems with existing systems in nuclear reactor facilities. However, nuclear waste management needs have developed which are much broader in scope and have different processing conditions. Numerous examples of air cleaning needs for waste management activities are provided; the major differences from operating facility needs are the requirement for continuous effluent treatment under widely different processing conditions. Related regulatory issues are also discussed briefly. 1 ref.

  4. Clean the Air and Breathe Easier.

    ERIC Educational Resources Information Center

    Guevin, John

    1997-01-01

    Failure to prevent indoor air quality problems or act promptly can result in increased chances for long- or short-term health problems for staff and students, reduced productivity, faster plant deterioration, and strained school-community relations. Basic pollution control measures include source management, local exhausts, ventilation, exposure…

  5. Indoor Air Quality in Schools: Clean Air Is Good Business.

    ERIC Educational Resources Information Center

    Guarneiri, Michele A.

    2003-01-01

    Describes the effect of poor indoor air quality (IAQ) on student health, the cost of safeguarding good IAQ, the cause of poor IAQ in schools, how to tell whether a school has an IAQ problem, and how the U.S. Environmental Protection Agency can help schools improve indoor air quality though the use of their free "Indoor Air Quality Tools for…

  6. Analysis of flight equipment purchasing practices of representative air carriers

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The process through which representative air carriers decide whether or not to purchase flight equipment was investigated as well as their practices and policies in retiring surplus aircraft. An analysis of the flight equipment investment decision process in ten airlines shows that for the airline industry as a whole, the flight equipment investment decision is in a state of transition from a wholly informal process in earliest years to a much more organized and structured process in the future. Individual air carriers are in different stages with respect to the formality and sophistication associated with the flight equipment investment decision.

  7. Selection of a Non-ODC Solvent for Rubber Processing Equipment Cleaning

    NASA Technical Reports Server (NTRS)

    Morgan, R. E.; Thornton, T. N.; Semmel, L.; Selvidge, S. A.

    2003-01-01

    NASA/MSFC has recently acquired new equipment for the manufacture and processing of rubber and rubber containing items that are used in the Redesigned Solid Rocket Motor (RSRM) system. Work with a previous generation of rubber equipment at MSFC in the 1970's had involved the use of Oxygen Deficient Center (ODC's) such as 1,1,1-Trichloroethane or VOC's such as Toluene as the solvents of choice in cleaning the equipment. Neither of these options is practical today. This paper addresses the selection and screening of candidate cleaning solvents that are not only effective, but also meet the new environmental standards.

  8. Selection of a Non-ODC Solvent for Rubber Processing Equipment Cleaning

    NASA Technical Reports Server (NTRS)

    Morgan, R. E.; Thornton, T. N.; Semmel, L.; Selvidge, S. A.; Cash, Steve (Technical Monitor)

    2002-01-01

    NASA/MSFC has recently acquired new equipment for the manufacture and processing of rubber and rubber containing items that are used in the RSRM (Reusable Solid Rocket Motor) system. Work with a previous generation of rubber equipment at MSFC (Marshall Space Flight Center) in the 1970's had involved the use of ODC's such as 1,1,1-Trichloroethane or VOC's such as Toluene as the solvents of choice in cleaning the equipment. Neither of these options is practical today. This paper addresses the selection and screening of candidate cleaning solvents that are not only effective, but also meet the new environmental standards.

  9. Comparison of materials used for cleaning equipment in retail food premises, and of two methods for the enumeration of bacteria on cleaned equipment and work surfaces.

    PubMed

    Gilbert, R J

    1970-06-01

    There is no official scheme for testing disinfectants and detergent/disinfectants for use in the retail food trade and few recommended procedures have been given for the cleaning of equipment with these agents. Therefore, field trials were carried out in a large self-service store. Comparisons were made of the various cleaning efficiencies, as determined by bacterial plate counts, of detergent and disinfectant solutions and machine cleaning oils applied with either clean cloths or disposable paper towels to items of equipment. The most satisfactory results were always obtained when anionic detergent (0.75% w/v) and hypochlorite (200 p.p.m. available chlorine) solutions were applied in a ;two-step' procedure.Tests were made to compare the calcium alginate swab-rinse and the agar sausage (Agaroid) techniques for the enumeration of bacteria on stainless steel, plastic, formica and wooden surfaces before and after a cleaning process. Although recovery rates were always greater by the swab-rinse technique, the agar sausage technique was considered to be a useful routine control method for surface sampling. PMID:4914087

  10. Plants Clean Air and Water for Indoor Environments

    NASA Technical Reports Server (NTRS)

    2007-01-01

    Wolverton Environmental Services Inc., founded by longtime government environmental scientist B.C. "Bill" Wolverton, is an environmental consulting firm that gives customers access to the results of his decades of cutting-edge bioremediation research. Findings about how to use plants to improve indoor air quality have been published in dozens of NASA technical papers and in the book, "How to Grow Fresh Air: 50 Houseplants That Purify Your Home or Office." The book has now been translated into 12 languages and has been on the shelves of bookstores for nearly 10 years. A companion book, "Growing Clean Water: Nature's Solution to Water Pollution," explains how plants can clean waste water. Other discoveries include that the more air that is allowed to circulate through the roots of the plants, the more effective they are at cleaning polluted air; and that plants play a psychological role in welfare in that people recover from illness faster in the presence of plants. Wolverton Environmental is also working in partnership with Syracuse University, to engineer systems consisting of modular wicking filters tied into duct work and water supplies, essentially tying plant-based filters into heating, ventilation, and air conditioning (HVAC) systems. Also, the company has recently begun to assess the ability of the EcoPlanter to remove formaldehyde from interior environments. Wolverton Environmental is also in talks with designers of the new Stennis Visitor's Center, who are interested in using its designs for indoor air-quality filters

  11. Enforcement provisions of the Clean Air Act Amendment of 1990

    SciTech Connect

    Hogan, E.A.; Davis, H.P.

    1994-12-31

    In discussing the provisions of the Clean Air Act Amendment of 1990, the authors focus on the following: EPA enforcement, including criminal and administrative civil penalties; NJDEPE enforcement authority, including criminal and administrative civil penalties, as well as economic benefit and judicial enforcement; citizens enforcement; and evidence of non compliance.

  12. 36. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" AIR FILTERS LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" AIR FILTERS LOOKING SOUTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  13. 18 CFR 1316.5 - Clean Air and Water Acts.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... meaning set forth in 40 CFR 15.4. (b) TVA will not award a contract to any offeror whose performance would... is exempt at the time of contract award from the provisions of 40 CFR part 15 as set forth therein... 18 Conservation of Power and Water Resources 2 2011-04-01 2011-04-01 false Clean Air and...

  14. 18 CFR 1316.5 - Clean Air and Water Acts.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... meaning set forth in 40 CFR 15.4. (b) TVA will not award a contract to any offeror whose performance would... is exempt at the time of contract award from the provisions of 40 CFR part 15 as set forth therein... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Clean Air and...

  15. 64. INTERIOR VIEW LOOKING DOWN LENGTH OF AIR CONDITIONING EQUIPMENT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    64. INTERIOR VIEW LOOKING DOWN LENGTH OF AIR CONDITIONING EQUIPMENT REPAIR SHOP. - Baltimore & Ohio Railroad, Mount Clare Shops, South side of Pratt Street between Carey & Poppleton Streets, Baltimore, Independent City, MD

  16. The Clean Air Act Amendments of 1990: Hazardous Air Pollutant Requirements and the DOE Clean Coal Technology Program

    SciTech Connect

    Moskowitz, P.D.; DePhillips, M.; Fthenakis, V.M.; Hemenway, A.

    1991-12-31

    The purpose of the US Department of Energy -- Office of Fossil Energy (DOE FE) Clean Coal Technology Program (CCTP) is to provide the US energy marketplace with advanced, efficient, and environmentally sound coal-based technologies. The design, construction, and operation of Clean Coal Technology Demonstration Projects (CCTDP) will generate data needed to make informed, confident decisions on the commercial readiness of these technologies. These data also will provide information needed to ensure a proactive response by DOE and its industrial partners to the establishment of new regulations or a reactive response to existing regulations promulgated by the US Environmental Protection Agency (EPA). The objectives of this paper are to: (1) Present a preliminary examination of the potential implications of the Clean Air Act Amendments (CAAA) -- Title 3 Hazardous Air Pollutant requirements to the commercialization of CCTDP; and (2) help define options available to DOE and its industrial partners to respond to this newly enacted Legislation.

  17. The Clean Air Act Amendments of 1990: Hazardous Air Pollutant Requirements and the DOE Clean Coal Technology Program

    SciTech Connect

    Moskowitz, P.D.; DePhillips, M.; Fthenakis, V.M. ); Hemenway, A. )

    1991-01-01

    The purpose of the US Department of Energy -- Office of Fossil Energy (DOE FE) Clean Coal Technology Program (CCTP) is to provide the US energy marketplace with advanced, efficient, and environmentally sound coal-based technologies. The design, construction, and operation of Clean Coal Technology Demonstration Projects (CCTDP) will generate data needed to make informed, confident decisions on the commercial readiness of these technologies. These data also will provide information needed to ensure a proactive response by DOE and its industrial partners to the establishment of new regulations or a reactive response to existing regulations promulgated by the US Environmental Protection Agency (EPA). The objectives of this paper are to: (1) Present a preliminary examination of the potential implications of the Clean Air Act Amendments (CAAA) -- Title 3 Hazardous Air Pollutant requirements to the commercialization of CCTDP; and (2) help define options available to DOE and its industrial partners to respond to this newly enacted Legislation.

  18. Cleaning products and air fresheners: exposure to primary and secondary air pollutants

    NASA Astrophysics Data System (ADS)

    Nazaroff, William W.; Weschler, Charles J.

    Building occupants, including cleaning personnel, are exposed to a wide variety of airborne chemicals when cleaning agents and air fresheners are used in buildings. Certain of these chemicals are listed by the state of California as toxic air contaminants (TACs) and a subset of these are regulated by the US federal government as hazardous air pollutants (HAPs). California's Proposition 65 list of species recognized as carcinogens or reproductive toxicants also includes constituents of certain cleaning products and air fresheners. In addition, many cleaning agents and air fresheners contain chemicals that can react with other air contaminants to yield potentially harmful secondary products. For example, terpenes can react rapidly with ozone in indoor air generating many secondary pollutants, including TACs such as formaldehyde. Furthermore, ozone-terpene reactions produce the hydroxyl radical, which reacts rapidly with organics, leading to the formation of other potentially toxic air pollutants. Indoor reactive chemistry involving the nitrate radical and cleaning-product constituents is also of concern, since it produces organic nitrates as well as some of the same oxidation products generated by ozone and hydroxyl radicals. Few studies have directly addressed the indoor concentrations of TACs that might result from primary emissions or secondary pollutant formation following the use of cleaning agents and air fresheners. In this paper, we combine direct empirical evidence with the basic principles of indoor pollutant behavior and with information from relevant studies, to analyze and critically assess air pollutant exposures resulting from the use of cleaning products and air fresheners. Attention is focused on compounds that are listed as HAPs, TACs or Proposition 65 carcinogens/reproductive toxicants and compounds that can readily react to generate secondary pollutants. The toxicity of many of these secondary pollutants has yet to be evaluated. The inhalation

  19. Unequal State Air Pollution: Adopting and Adapting to State Clean Air Policy

    NASA Astrophysics Data System (ADS)

    Glasgow, Derek John

    This dissertation looks at the relationship between American subnational governments and clean air policy in three different cases. I investigate the impact of state reduction policies on the emission of Greenhouse emissions, the subnational adoption of Greenhouse Gas tracking and reduction policies, and the impact of Clean Air Act standards on the siting of coal-fired power plants. The major finding is that in both the adoption and business response to these policies, a state's political context can limit its ability to regulate air pollution. These factors contribute to the unequal protection of air quality across the United States.

  20. 40 CFR 63.5737 - How do I demonstrate compliance with the resin and gel coat application equipment cleaning...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the resin and gel coat application equipment cleaning standards? 63.5737 Section 63.5737 Protection of... Pollutants for Boat Manufacturing Standards for Resin and Gel Coat Application Equipment Cleaning Operations § 63.5737 How do I demonstrate compliance with the resin and gel coat application equipment...

  1. 40 CFR 63.5737 - How do I demonstrate compliance with the resin and gel coat application equipment cleaning...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the resin and gel coat application equipment cleaning standards? 63.5737 Section 63.5737 Protection of... Pollutants for Boat Manufacturing Standards for Resin and Gel Coat Application Equipment Cleaning Operations § 63.5737 How do I demonstrate compliance with the resin and gel coat application equipment...

  2. 75 FR 7627 - Notice of Lodging of Material Modification to Consent Decree under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-22

    ... of Lodging of Material Modification to Consent Decree under the Clean Air Act Pursuant to Department of Justice policy, notice is hereby given that, on February 4, 2010, a proposed First Material... equipment to capture and recycle the vast majority of the hot water that is condensed from its use of...

  3. Cleaning efficacy of high-efficiency particulate air-filtered vacuuming and "dry steam" cleaning on carpet.

    PubMed

    Yiin, Lih-Ming; Yu, Chang Ho; Ashley, Peter; Rhoads, George

    2008-02-01

    Previous studies for lead exposure reduction have indicated the difficulty in reducing surface contamination of carpets with the use of regular vacuum cleaners. To find a solution, a household vacuum cleaner equipped with a high-efficiency particulate air (HEPA) filter and a dust finder indicator, and a "dry steam" cleaner previously reported effective in reducing dust mite allergens in carpets and mattresses were tested for effectiveness in reducing lead dust in carpets. Fifty homes of lead-exposed children were tested in New Jersey. A selected carpet in the living area of each home was tested with two interventions: half was cleaned by HEPA vacuuming twice (VAC-VAC) and the other half by dry steaming between the two HEPA vacuumings (VAC-DSC-VAC). Wipe and vacuum samples, representing surface dust and total dust collections, respectively, were taken before and after cleaning. The wipe and vacuum sample data indicated that both cleaning methods substantially reduced dust lead levels (p < 0.001). The mean percent reductions in lead loading were approximately 29% and 40% for the VAC-VAC and VAC-DSC-VAC interventions, respectively. The difference between the two postcleaning levels was statistically significant by wipe sampling (p = 0.038) but was marginally insignificant by vacuum sampling (p = 0.072). A subset of sample data collected before repeat vacuuming (VAC-DSC) suggested that repeat vacuuming after dry steam cleaning is unnecessary. In summary, slow and steady HEPA vacuuming with the help of a dust finder indicator reduces surface and overall lead dust in carpets, and dry steam cleaning further reduces surface lead contamination as compared with HEPA vacuuming alone.

  4. Cleaning efficacy of high-efficiency particulate air-filtered vacuuming and "dry steam" cleaning on carpet.

    PubMed

    Yiin, Lih-Ming; Yu, Chang Ho; Ashley, Peter; Rhoads, George

    2008-02-01

    Previous studies for lead exposure reduction have indicated the difficulty in reducing surface contamination of carpets with the use of regular vacuum cleaners. To find a solution, a household vacuum cleaner equipped with a high-efficiency particulate air (HEPA) filter and a dust finder indicator, and a "dry steam" cleaner previously reported effective in reducing dust mite allergens in carpets and mattresses were tested for effectiveness in reducing lead dust in carpets. Fifty homes of lead-exposed children were tested in New Jersey. A selected carpet in the living area of each home was tested with two interventions: half was cleaned by HEPA vacuuming twice (VAC-VAC) and the other half by dry steaming between the two HEPA vacuumings (VAC-DSC-VAC). Wipe and vacuum samples, representing surface dust and total dust collections, respectively, were taken before and after cleaning. The wipe and vacuum sample data indicated that both cleaning methods substantially reduced dust lead levels (p < 0.001). The mean percent reductions in lead loading were approximately 29% and 40% for the VAC-VAC and VAC-DSC-VAC interventions, respectively. The difference between the two postcleaning levels was statistically significant by wipe sampling (p = 0.038) but was marginally insignificant by vacuum sampling (p = 0.072). A subset of sample data collected before repeat vacuuming (VAC-DSC) suggested that repeat vacuuming after dry steam cleaning is unnecessary. In summary, slow and steady HEPA vacuuming with the help of a dust finder indicator reduces surface and overall lead dust in carpets, and dry steam cleaning further reduces surface lead contamination as compared with HEPA vacuuming alone. PMID:18075882

  5. 44. Communication equipment room, cable air dryer on left, motorola ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. Communication equipment room, cable air dryer on left, motorola base station (vhf) in center, telephone repeater group at right, looking west - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  6. The Sensing Technology for Air-Conditioning Equipments

    NASA Astrophysics Data System (ADS)

    Matsuzaka, Takashi

    Various kinds of sensor are used for control of air-conditioning equipments. In this paper, examples of control system using some kinks of sensor about improvement of amenity are introduced. Humidity control methods using ceramic humidity sonsor, temperature-radiation-air flow control methods using amenity sensor, zone control methods using human detecting sensor and IAQ control methods using gas sensor, are discussed.

  7. An introduction to the design, commissioning and operation of nuclear air cleaning systems for Qinshan Nuclear Power Plant

    SciTech Connect

    Xinliang Chen; Jiangang Qu; Minqi Shi

    1995-02-01

    This paper introduces the design evolution, system schemes and design and construction of main nuclear air cleaning components such as HEPA filter, charcoal adsorber and concrete housing etc. for Qinshan 300MW PWR Nuclear Power Plant (QNPP), the first indigenously designed and constructed nuclear power plant in China. The field test results and in-service test results, since the air cleaning systems were put into operation 18 months ago, are presented and evaluated. These results demonstrate that the design and construction of the air cleaning systems and equipment manufacturing for QNPP are successful and the American codes and standards invoked in design, construction and testing of nuclear air cleaning systems for QNPP are applicable in China. The paper explains that the leakage rate of concrete air cleaning housings can also be assured if sealing measures are taken properly and embedded parts are designed carefully in the penetration areas of the housing and that the uniformity of the airflow distribution upstream the HEPA filters can be achieved generally no matter how inlet and outlet ducts of air cleaning unit are arranged.

  8. 40 CFR 49.10 - EPA review of State Clean Air Act programs.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false EPA review of State Clean Air Act programs. 49.10 Section 49.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER... of State Clean Air Act programs. A State Clean Air Act program submittal shall not be...

  9. 40 CFR 49.3 - General Tribal Clean Air Act authority.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false General Tribal Clean Air Act authority... ASSISTANCE INDIAN COUNTRY: AIR QUALITY PLANNING AND MANAGEMENT Tribal Authority § 49.3 General Tribal Clean... manner as States with respect to all provisions of the Clean Air Act and implementing regulations,...

  10. 40 CFR 49.10 - EPA review of State Clean Air Act programs.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false EPA review of State Clean Air Act programs. 49.10 Section 49.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER... of State Clean Air Act programs. A State Clean Air Act program submittal shall not be...

  11. 40 CFR 49.10 - EPA review of State Clean Air Act programs.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 1 2013-07-01 2013-07-01 false EPA review of State Clean Air Act programs. 49.10 Section 49.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER... of State Clean Air Act programs. A State Clean Air Act program submittal shall not be...

  12. 40 CFR 49.3 - General Tribal Clean Air Act authority.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 1 2012-07-01 2012-07-01 false General Tribal Clean Air Act authority... ASSISTANCE INDIAN COUNTRY: AIR QUALITY PLANNING AND MANAGEMENT Tribal Authority § 49.3 General Tribal Clean... manner as States with respect to all provisions of the Clean Air Act and implementing regulations,...

  13. 40 CFR 49.9 - EPA review of tribal Clean Air Act applications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 1 2013-07-01 2013-07-01 false EPA review of tribal Clean Air Act... of tribal Clean Air Act applications. (a) The EPA Regional Administrator shall process a request of... apply to all future Clean Air Act applications from that tribe or tribal consortium and no...

  14. 40 CFR 49.3 - General Tribal Clean Air Act authority.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false General Tribal Clean Air Act authority... ASSISTANCE INDIAN COUNTRY: AIR QUALITY PLANNING AND MANAGEMENT Tribal Authority § 49.3 General Tribal Clean... manner as States with respect to all provisions of the Clean Air Act and implementing regulations,...

  15. 40 CFR 49.9 - EPA review of tribal Clean Air Act applications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 1 2012-07-01 2012-07-01 false EPA review of tribal Clean Air Act... of tribal Clean Air Act applications. (a) The EPA Regional Administrator shall process a request of... apply to all future Clean Air Act applications from that tribe or tribal consortium and no...

  16. 40 CFR 49.9 - EPA review of tribal Clean Air Act applications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false EPA review of tribal Clean Air Act... of tribal Clean Air Act applications. (a) The EPA Regional Administrator shall process a request of... apply to all future Clean Air Act applications from that tribe or tribal consortium and no...

  17. 40 CFR 49.9 - EPA review of tribal Clean Air Act applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false EPA review of tribal Clean Air Act... of tribal Clean Air Act applications. (a) The EPA Regional Administrator shall process a request of... apply to all future Clean Air Act applications from that tribe or tribal consortium and no...

  18. 40 CFR 49.10 - EPA review of State Clean Air Act programs.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 1 2012-07-01 2012-07-01 false EPA review of State Clean Air Act programs. 49.10 Section 49.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER... of State Clean Air Act programs. A State Clean Air Act program submittal shall not be...

  19. 40 CFR 49.3 - General Tribal Clean Air Act authority.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 1 2013-07-01 2013-07-01 false General Tribal Clean Air Act authority... ASSISTANCE INDIAN COUNTRY: AIR QUALITY PLANNING AND MANAGEMENT Tribal Authority § 49.3 General Tribal Clean... manner as States with respect to all provisions of the Clean Air Act and implementing regulations,...

  20. 14 CFR 1274.926 - Clean Air-Water Pollution Control Acts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 5 2011-01-01 2010-01-01 true Clean Air-Water Pollution Control Acts. 1274... AGREEMENTS WITH COMMERCIAL FIRMS Other Provisions and Special Conditions § 1274.926 Clean Air-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative agreement or...

  1. 40 CFR 49.9 - EPA review of tribal Clean Air Act applications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false EPA review of tribal Clean Air Act... FEDERAL ASSISTANCE TRIBAL CLEAN AIR ACT AUTHORITY Tribal Authority § 49.9 EPA review of tribal Clean Air... boundaries of a reservation or tribal jurisdiction over non-reservation areas shall apply to all future...

  2. 75 FR 22787 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-30

    ... AGENCY Proposed Settlement Agreement, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency... accordance with section 113(g) of the Clean Air Act, as amended (``Act''), 42 U.S.C. 7413(g), notice is... the Clean Air Act and asking the court to enter judgment: (i) Declaring that EPA's failure to...

  3. 78 FR 77448 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-23

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... public meetings of the Clean Air Act Advisory Committee (CAAAC). The EPA established the CAAAC on... implementation of the Clean Air Act of 1990. The Committee advises on economic, environmental,...

  4. 76 FR 9610 - Notice of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-18

    ... of Proposed Consent Decree Under the Clean Air Act Notice is hereby given that on February 14, 2011... California. The Consent Decree in this Clean Air Act enforcement action resolves allegations by the...''), asserted in a complaint filed together with the Consent Decree, under Section 113(b) of the Clean Air...

  5. 77 FR 39493 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-03

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA''), notice is hereby given of a proposed consent... Amended Complaint alleging that EPA failed to perform nondiscretionary duties under the Clean Air...

  6. 76 FR 65722 - Notification of Two Public Teleconferences; Clean Air Scientific Advisory Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-24

    ... AGENCY Notification of Two Public Teleconferences; Clean Air Scientific Advisory Committee AGENCY... Clean Air Scientific Advisory Committee (CASAC) to discuss its draft review of EPA's Integrated Science... CASAC was established pursuant to the under the Clean Air Act (CAA) Amendments of 1977, codified at 42...

  7. 76 FR 25688 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-05

    ... AGENCY Proposed Settlement Agreement, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency... accordance with section 113(g) of the Clean Air Act, as amended (``CAA''), 42 U.S.C. 7413(g), notice is... to a CAA Title V operating permit issued by the Southwest Clean Air Agency to Transalta...

  8. 77 FR 65684 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-30

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA''), notice is hereby given of a proposed consent... Amended Complaint alleging that EPA failed to perform nondiscretionary duties under the Clean Air...

  9. 76 FR 9609 - Notice of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-18

    ... of Proposed Consent Decree Under the Clean Air Act Notice is hereby given that on February 14, 2011... Consent Decree in this Clean Air Act enforcement action resolves allegations by the Environmental... in a complaint filed together with the Consent Decree, under Section 113(b) of the Clean Air Act,...

  10. 78 FR 49511 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-14

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... public meeting of the Clean Air Act Advisory Committee (CAAAC). The EPA established the CAAAC on November... implementation of the Clean Air Act of 1990. The Committee advises on economic, environmental,...

  11. Air Cleaning Devices for HVAC Supply Systems in Schools. Technical Bulletin.

    ERIC Educational Resources Information Center

    Wheeler, Arthur E.

    Guidelines for maintaining indoor air quality in schools with HVAC air cleaning systems are provided in this document. Information is offered on the importance of air cleaning, sources of air contaminants and indoor pollutants, types of air cleaners and particulate filters used in central HVAC systems, vapor and gas removal, and performance…

  12. 75 FR 32857 - Approval and Promulgation of Air Quality Implementation Plans; Virginia; Revision to Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-10

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Virginia; Revision to Clean Air Interstate Rule Sulfur Dioxide Trading Program Correction In final rule document...

  13. 40 CFR 61.152 - Air-cleaning.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... filtering air from asbestos ore dryers; and (ii) Ensuring that felted fabric weighs at least 475 grams per... with a unit contacting energy of at least 9.95 kilopascals (40 inches water gage pressure). (2) Use a... Administrator may authorize the use of filtering equipment other than described in paragraphs (a)(1) and...

  14. 40 CFR 61.152 - Air-cleaning.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... filtering air from asbestos ore dryers; and (ii) Ensuring that felted fabric weighs at least 475 grams per... with a unit contacting energy of at least 9.95 kilopascals (40 inches water gage pressure). (2) Use a... Administrator may authorize the use of filtering equipment other than described in paragraphs (a)(1) and...

  15. 40 CFR 61.152 - Air-cleaning.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... filtering air from asbestos ore dryers; and (ii) Ensuring that felted fabric weighs at least 475 grams per... with a unit contacting energy of at least 9.95 kilopascals (40 inches water gage pressure). (2) Use a... Administrator may authorize the use of filtering equipment other than described in paragraphs (a)(1) and...

  16. 40 CFR 61.152 - Air-cleaning.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... filtering air from asbestos ore dryers; and (ii) Ensuring that felted fabric weighs at least 475 grams per... with a unit contacting energy of at least 9.95 kilopascals (40 inches water gage pressure). (2) Use a... Administrator may authorize the use of filtering equipment other than described in paragraphs (a)(1) and...

  17. A pilot study of energy efficient air cleaning for ozone

    SciTech Connect

    Gundel, Lara A.; Sullivan, Douglas P.; Katsapov, Gregory Y.; Fisk, William J.

    2002-11-01

    A laboratory pilot study has been undertaken with the material that showed the most promise (high capacity and low pressure drop) based on the literature review and associated calculations. The best-performing air cleaner was a commercially available pleated filter that contained a thin layer of small activated carbon particles between two sheets of non-woven fibrous webbing. We will refer to this unit as the ''ozone filter'' although it is marketed for removal of volatile organic compounds (VOCs) from automobile passenger compartments. This pilot study strongly suggests that ozone air cleaning can be practical in commercial air handling systems; however, further tests are needed to assess air cleaner performance under a wider range of conditions.

  18. Asthma, sulfur dioxide, and the Clean Air Act

    SciTech Connect

    Boushey, H.

    1982-02-01

    Laboratory findings on the effects of sulfur dioxide in patients with asthma are related to theories about the mechanisms of bronchial hyperreactivity, an abnormality that may be fundamental to the pathogenesis of asthma and then to questions of national policy on air quality. Work has shown that people with asthma are abnormally sensitive to inhalation of sulfur dioxide and that bronchospasm may develop if they pursue activities that require light exercise while breathing air containing a level of sulfur dioxide permitted by current ambient air-quality standards. The provisions of the Clean Air Act of 1970 require that sensitive groups in the population be protected against adverse health effects, and our data therefore indicate the need for a short-term standard for sulfur dioxide.

  19. Ceramic membrane defouling (cleaning) by air Nano Bubbles.

    PubMed

    Ghadimkhani, Aliasghar; Zhang, Wen; Marhaba, Taha

    2016-03-01

    Ceramic membranes are among the most promising technologies for membrane applications, owing to their excellent resistance to mechanical, chemical, and thermal stresses. However, membrane fouling is still an issue that hampers the applications at large scales. Air Nano Bubbles (NBs), due to high mass transfer efficiency, could potentially prevent fouling of ceramic membrane filtration processes. In this study, bench and pilot scale ceramic membrane filtration was performed with air NBs to resist fouling. To simulate fouling, humic acid, as an organic foulant, was applied to the membrane flat sheet surface. Complete membrane clogging was achieved in less than 6 h. Membrane defouling (cleaning) was performed by directly feeding of air NBs to the membrane cells. The surface of the ceramic membrane was superbly cleaned by air NBs, as revealed by atomic force microscope (AFM) images before and after the treatment. The permeate flux recovered to its initial level (e.g., 26.7 × 10(-9) m(3)/m(2)/s at applied pressure of 275.8 kPa), which indicated that NBs successfully unclogged the pores of the membrane. The integrated ceramic membrane and air NBs system holds potential as an innovative sustainable technology.

  20. Ceramic membrane defouling (cleaning) by air Nano Bubbles.

    PubMed

    Ghadimkhani, Aliasghar; Zhang, Wen; Marhaba, Taha

    2016-03-01

    Ceramic membranes are among the most promising technologies for membrane applications, owing to their excellent resistance to mechanical, chemical, and thermal stresses. However, membrane fouling is still an issue that hampers the applications at large scales. Air Nano Bubbles (NBs), due to high mass transfer efficiency, could potentially prevent fouling of ceramic membrane filtration processes. In this study, bench and pilot scale ceramic membrane filtration was performed with air NBs to resist fouling. To simulate fouling, humic acid, as an organic foulant, was applied to the membrane flat sheet surface. Complete membrane clogging was achieved in less than 6 h. Membrane defouling (cleaning) was performed by directly feeding of air NBs to the membrane cells. The surface of the ceramic membrane was superbly cleaned by air NBs, as revealed by atomic force microscope (AFM) images before and after the treatment. The permeate flux recovered to its initial level (e.g., 26.7 × 10(-9) m(3)/m(2)/s at applied pressure of 275.8 kPa), which indicated that NBs successfully unclogged the pores of the membrane. The integrated ceramic membrane and air NBs system holds potential as an innovative sustainable technology. PMID:26741542

  1. Equipment for Measuring Air Flow, Air Temperature, Relative Humidity, and Carbon Dioxide in Schools. Technical Bulletin.

    ERIC Educational Resources Information Center

    Jacobs, Bruce W.

    Information on equipment and techniques that school facility personnel may use to evaluate IAQ conditions are discussed. Focus is placed on the IAQ parameters of air flow, air temperature, relative humidity, as well as carbon dioxide and the equipment used to measure these factors. Reasons for measurement and for when the measurement of these…

  2. 9 CFR 71.7 - Means of conveyance, facilities, premises, and cages and other equipment; methods of cleaning and...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., premises, and cages and other equipment; methods of cleaning and disinfecting. 71.7 Section 71.7 Animals..., facilities, premises, and cages and other equipment; methods of cleaning and disinfecting. (a) Railroad cars... animals or with which they may come in contact or which have contained litter or manure. (c) Yards,...

  3. 9 CFR 71.7 - Means of conveyance, facilities, premises, and cages and other equipment; methods of cleaning and...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., premises, and cages and other equipment; methods of cleaning and disinfecting. 71.7 Section 71.7 Animals..., facilities, premises, and cages and other equipment; methods of cleaning and disinfecting. (a) Railroad cars... animals or with which they may come in contact or which have contained litter or manure. (c) Yards,...

  4. 9 CFR 71.7 - Means of conveyance, facilities, premises, and cages and other equipment; methods of cleaning and...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., premises, and cages and other equipment; methods of cleaning and disinfecting. 71.7 Section 71.7 Animals..., facilities, premises, and cages and other equipment; methods of cleaning and disinfecting. (a) Railroad cars... animals or with which they may come in contact or which have contained litter or manure. (c) Yards,...

  5. 9 CFR 71.7 - Means of conveyance, facilities, premises, and cages and other equipment; methods of cleaning and...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., premises, and cages and other equipment; methods of cleaning and disinfecting. 71.7 Section 71.7 Animals..., facilities, premises, and cages and other equipment; methods of cleaning and disinfecting. (a) Railroad cars... animals or with which they may come in contact or which have contained litter or manure. (c) Yards,...

  6. 9 CFR 71.7 - Means of conveyance, facilities, premises, and cages and other equipment; methods of cleaning and...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., premises, and cages and other equipment; methods of cleaning and disinfecting. 71.7 Section 71.7 Animals..., facilities, premises, and cages and other equipment; methods of cleaning and disinfecting. (a) Railroad cars... animals or with which they may come in contact or which have contained litter or manure. (c) Yards,...

  7. 75 FR 51807 - Science Advisory Board Staff Office; Notification of a Public Teleconference of the Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-23

    ... Scientific Advisory Committee (CASAC) Ambient Air Methods and Monitoring Subcommittee (AAMMS) AGENCY..., 2010, of the Clean Air Scientific Advisory Committee (CASAC) Ambient Air Monitoring & Methods... Method for Lead (Pb) in Total Suspended Particulates (TSP). The Clean Air Scientific Advisory...

  8. 75 FR 9208 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-01

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA''), 42 U.S.C. 7413(g), notice is hereby given of a... Waterkeeper, Inc., Clean Water Action, and Chesapeake Climate Action Network (collectively ``Plaintiffs'')...

  9. Cleaning and sanitation of Salmonella-contaminated peanut butter processing equipment.

    PubMed

    Grasso, Elizabeth M; Grove, Stephen F; Halik, Lindsay A; Arritt, Fletcher; Keller, Susanne E

    2015-04-01

    Microbial contamination of peanut butter by Salmonella poses a significant health risk as Salmonella may remain viable throughout the product shelf life. Effective cleaning and sanitation of processing lines are essential for preventing cross-contamination. The objective of this study was to evaluate the efficacy of a cleaning and sanitation procedure involving hot oil and 60% isopropanol, ± quaternary ammonium compounds, to decontaminate pilot-scale processing equipment harboring Salmonella. Peanut butter inoculated with a cocktail of four Salmonella serovars (∼ 7 log CFU/g) was used to contaminate the equipment (∼ 75 L). The system was then emptied of peanut butter and treated with hot oil (90 °C) for 2 h followed by sanitizer for 1 h. Microbial analysis of food-contact surfaces (7 locations), peanut butter, and oil were conducted. Oil contained ∼ 3.2 log CFU/mL on both trypticase soy agar with yeast extract (TSAYE) and xylose lysine deoxycholate (XLD), indicating hot oil alone was not sufficient to inactivate Salmonella. Environmental sampling found 0.25-1.12 log CFU/cm(2) remaining on processing equipment. After the isopropanol sanitation (± quaternary ammonium compounds), no Salmonella was detected in environmental samples on XLD (<0.16 log CFU/cm(2)). These data suggest that a two-step hot oil clean and isopropanol sanitization treatment may eliminate pathogenic Salmonella from contaminated equipment. PMID:25475272

  10. Cleaning and sanitation of Salmonella-contaminated peanut butter processing equipment.

    PubMed

    Grasso, Elizabeth M; Grove, Stephen F; Halik, Lindsay A; Arritt, Fletcher; Keller, Susanne E

    2015-04-01

    Microbial contamination of peanut butter by Salmonella poses a significant health risk as Salmonella may remain viable throughout the product shelf life. Effective cleaning and sanitation of processing lines are essential for preventing cross-contamination. The objective of this study was to evaluate the efficacy of a cleaning and sanitation procedure involving hot oil and 60% isopropanol, ± quaternary ammonium compounds, to decontaminate pilot-scale processing equipment harboring Salmonella. Peanut butter inoculated with a cocktail of four Salmonella serovars (∼ 7 log CFU/g) was used to contaminate the equipment (∼ 75 L). The system was then emptied of peanut butter and treated with hot oil (90 °C) for 2 h followed by sanitizer for 1 h. Microbial analysis of food-contact surfaces (7 locations), peanut butter, and oil were conducted. Oil contained ∼ 3.2 log CFU/mL on both trypticase soy agar with yeast extract (TSAYE) and xylose lysine deoxycholate (XLD), indicating hot oil alone was not sufficient to inactivate Salmonella. Environmental sampling found 0.25-1.12 log CFU/cm(2) remaining on processing equipment. After the isopropanol sanitation (± quaternary ammonium compounds), no Salmonella was detected in environmental samples on XLD (<0.16 log CFU/cm(2)). These data suggest that a two-step hot oil clean and isopropanol sanitization treatment may eliminate pathogenic Salmonella from contaminated equipment.

  11. NASA's Principal Center for Review of Clean Air Act Regulations

    NASA Technical Reports Server (NTRS)

    Clark-Ingram, Marceia

    2003-01-01

    Marshall Space Flight Center (MSFC) was selected as the Principal Center for review of Clean Air Act (CAA) regulations. The CAA Principal Center is tasked to: 1) Provide centralized support to NASA/HDQ Code JE for the management and leadership of NASA's CAA regulation review process; 2) Identify potential impact from proposed CAA regulations to NASA program hardware and supporting facilities. The Shuttle Environmental Assurance Initiative, one of the responsibilities of the NASA CAA Working Group (WG), is described in part of this viewgraph presentation.

  12. Investigation of air cleaning system response to accident conditions

    SciTech Connect

    Andrae, R.W.; Bolstad, J.W.; Foster, R.D.; Gregory, W.S.; Horak, H.L.; Idar, E.S.; Martin, R.A.; Ricketts, C.I.; Smith, P.R.; Tang, P.K.

    1980-01-01

    Air cleaning system response to the stress of accident conditions are being investigated. A program overview and hghlight recent results of our investigation are presented. The program includes both analytical and experimental investigations. Computer codes for predicting effects of tornados, explosions, fires, and material transport are described. The test facilities used to obtain supportive experimental data to define structural integrity and confinement effectiveness of ventilation system components are described. Examples of experimental results for code verification, blower response to tornado transients, and filter response to tornado and explosion transients are reported.

  13. PROTECTING ECOLOGICAL RESOURCES WITH THE CLEAN AIR ACT: THE ROLE OF SCIENCE

    EPA Science Inventory

    The Clean Air Act provides for establishing National Ambient Air Quality Standards (NAAQS) to protect public welfare (including crops, forests, ecosystems, and soils) from adverse effects of air pollutants, including tropospheric ozone. The formulation of policies is science-base...

  14. Applying the Clean Air Act to municipal solid waste landfills

    SciTech Connect

    Heitz, D.R.; Romzick, P.G.

    1998-12-31

    On March 12, 1996, the EPA promulgated the new Source Performance Standards (NSPS) for Municipal Solid Waste (MSW) Landfills, the first federal air regulation specifically for MSW landfills. Landfills subject to this regulation which exceeded the threshold design capacity also became subject to the Title V operating permit program. This began the application of the Clean Air Act (CAA) to most of these nontraditional air sources. Unlike landfills, typical air sources have easily defined input capacities that correspond to potential emissions while the process creates a product or output. All these concepts are difficult and confusing to apply to MSW landfills. Applicability of the following CAA regulations are specifically addressed in this paper: NSPS for MSW landfills; new Source Review (NSR)/Prevention of Significant Deterioration (PSD); landfill Maximum Achievable Control Technologies (MACT); 112(g) Modification of Major Sources of Hazardous Air Pollutants (HAP); 112(r) Accidental Release Prevention; and Title V. Along with summarizing the potential applicability of each, the main issues are presented along with the current information on the regulations.

  15. The high efficiency steel filters for nuclear air cleaning

    SciTech Connect

    Bergman, W.; Larsen, G.; Lopez, R.; Williams, K.; Violet, C.

    1990-08-01

    We have, in cooperation with industry, developed high-efficiency filters made from sintered stainless-steel fibers for use in several air-cleaning applications in the nuclear industry. These filters were developed to overcome the failure modes in present high-efficiency particulate air (HEPA) filters. HEPA filters are made from glass paper and glue, and they may fail when they get hot or wet and when they are overpressured. In developing our steel filters, we first evaluated the commercially available stainless-steel filter media made from sintered powder and sintered fiber. The sintered-fiber media performed much better than sintered-powder media, and the best media had the smallest fiber diameter. Using the best media, we then built prototype filters for venting compressed gases and evaluated them in our automated filter tester. 12 refs., 20 figs.

  16. 75 FR 42130 - Notice of Lodging of Consent Decree Under the Clean Air Act; Clean Water Act; Resource...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-20

    ... of Lodging of Consent Decree Under the Clean Air Act; Clean Water Act; Resource Conservation and Recovery Act; Safe Drinking Water Act; Toxic Substances Control Act; and the Reporting Requirements of the... U.S.C. 6901 to 6992k; Safe Drinking Water Act (``SDWA''), 42 U.S.C. 300f to 300j-26;...

  17. Methods for measuring performance of vehicle cab air cleaning systems against aerosols and vapours.

    PubMed

    Bémer, D; Subra, I; Régnier, R

    2009-06-01

    Vehicle cabs equipped with an effective air cleaning and pressurization system, fitted to agricultural and off-road machineries, isolate drivers from the polluted environment, in which they are likely to work. These cabs provide protection against particulate and gaseous pollutants generated by these types of work activities. Two laboratory methods have been applied to determining the performance characteristics of two cabs of different design, namely, optical counting-based measurement of a potassium chloride (KCl) aerosol and fluorescein aerosol-based tracing. Results of cab confinement efficiency measurements agreed closely for these two methods implemented in the study. Measurements showed that high confinement efficiencies can be achieved with cabs, which are properly designed in ventilation/cleaning/airtightness terms. We also noted the importance of filter mounting airtightness, in which the smallest defect is reflected by significant degradation in cab performance. Determination of clean airflow rate by monitoring the decrease in test aerosol concentration in the test chamber gave excellent results. This method could represent an attractive alternative to methods involving gas tracing or air velocity measurement at blowing inlets.

  18. Methods for measuring performance of vehicle cab air cleaning systems against aerosols and vapours.

    PubMed

    Bémer, D; Subra, I; Régnier, R

    2009-06-01

    Vehicle cabs equipped with an effective air cleaning and pressurization system, fitted to agricultural and off-road machineries, isolate drivers from the polluted environment, in which they are likely to work. These cabs provide protection against particulate and gaseous pollutants generated by these types of work activities. Two laboratory methods have been applied to determining the performance characteristics of two cabs of different design, namely, optical counting-based measurement of a potassium chloride (KCl) aerosol and fluorescein aerosol-based tracing. Results of cab confinement efficiency measurements agreed closely for these two methods implemented in the study. Measurements showed that high confinement efficiencies can be achieved with cabs, which are properly designed in ventilation/cleaning/airtightness terms. We also noted the importance of filter mounting airtightness, in which the smallest defect is reflected by significant degradation in cab performance. Determination of clean airflow rate by monitoring the decrease in test aerosol concentration in the test chamber gave excellent results. This method could represent an attractive alternative to methods involving gas tracing or air velocity measurement at blowing inlets. PMID:19406910

  19. A breath of fresh air: EPA`s more flexible approach to the Clean Air Act

    SciTech Connect

    Curreri, J.A.

    1996-05-01

    This article highlights the changes in the Clean Air Act rules as defined by the USEPA. The major changes discussed include the following: definition of a `major source`; streamlined Title V Permits; less detailed descriptions; permit revisions may be reduced; periodic and enhanced monitoring; more practical requirements; case-by-case MACT standards.

  20. An overview of 1990 Clean Air Act Amendments as related to engineering and maintenance aspects

    SciTech Connect

    Mehta, Y.M. )

    1994-03-01

    Titles I and III of the 1990 Clean Air Act Amendments will regulate nonattainment-area pollutants (ozone, CO, PM-10, SO[sub 2], NO[sub x], and lead) and hazardous air pollutants, respectively. These regulations will have a significant impact on existing and new pulp and paper facilities. Several states have already addressed Title I requirements in their State Implementation Plans. As for Title III, the Environmental Protection Agency plans to propose emission standards for chemical pulping/bleaching facilities by Oct. 1993, with promulgation by Sept. 1995. This report summarizes the anticipated requirements and highlights their impact on the pulp and paper industry. The new regulations will require many facilities to modify existing equipment and/or install new pollution-control devices.

  1. 77 FR 14830 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-13

    ... of Lodging of Consent Decree Under the Clean Air Act Notice is hereby given that on March 6, 2012, a... against Spectro Alloys Corporation pursuant to Section 113(b) of the Clean Air Act, 42 U.S.C. 7413(b... results in emissions of regulated air pollutants, including dioxins and furans, hydrogen...

  2. Clean-air video will interest MDs who treat patients with allergies, respiratory problems.

    PubMed

    Rafuse, J

    1996-03-15

    Canada Mortgage and Housing Corporation wants physicians to help raise public awareness abut the importance of indoor air quality to health. Physicians across Canada are being sent a colourful poster that calls attention to indoor air pollution and ways to make a home healthier, included are order forms for the Clean Air Guide and a companion video, This Clean House. PMID:8634972

  3. 78 FR 43200 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-19

    ... 1997 8-hour ozone national ambient air quality standard in the South Coast. 77 FR 12674 (March 1, 2012... AGENCY Proposed Settlement Agreement, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency... accordance with section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), notice is...

  4. Proceedings of the 21st DOE/NRC Nuclear Air Cleaning Conference; Sessions 1--8

    SciTech Connect

    First, M.W.

    1991-02-01

    Separate abstracts have been prepared for the papers presented at the meeting on nuclear facility air cleaning technology in the following specific areas of interest: air cleaning technologies for the management and disposal of radioactive wastes; Canadian waste management program; radiological health effects models for nuclear power plant accident consequence analysis; filter testing; US standard codes on nuclear air and gas treatment; European community nuclear codes and standards; chemical processing off-gas cleaning; incineration and vitrification; adsorbents; nuclear codes and standards; mathematical modeling techniques; filter technology; safety; containment system venting; and nuclear air cleaning programs around the world. (MB)

  5. Investigation of flushing and clean-out methods for refrigeration equipment to ensure system compatibility

    SciTech Connect

    Byrne, J.J.; Shows, M.; Abel, M.W.

    1996-04-24

    SECTION 608 of the Clean Air Act Amendments has altered much of the refrigeration service contracting industry. MCLR Project Number 660-52502 was established to examine two areas where the Amendments are influencing contractors to determine if more cost-effective service procedures might be developed. One area where existing service procedures are being revisited involves the removal of contaminants from a refrigeration system after a motor burnout. At one time, a Class 1 substance such as CFC-11 or CFC-113 was used as a flushing agent for cleaning a system after a burnout. On large systems, the compressor was disassembled, and the parts were cleaned using 1,1,1-trichloroethane (TCA) or a TCA-containing mixture. Such alternatives are seldom possible today, as the manufacture of Class 1 substances was banned on January 1, 1996. This report describes processes for mineral oil removal, process alternatives for servicing burnouts, solvents, and laboratory retrofit tests.

  6. Indoor air cleaning using a pulsed discharge plasma

    SciTech Connect

    Mizuno, Akira; Kisanuki, Yoshiyuki; Noguchi, Masanobu; Katsura, Shinji; Lee, S.H.; Hong, Y.K.; Shin, S.Y.; Kang, J.H.

    1999-12-01

    The purpose of this paper is to develop a high-efficiency air-cleaning system for air pollutants such as tobacco smoke found in indoor environments. The authors investigated the basic characteristics of treating particulate matter and acetaldehyde (CH{sub 3}CHO) in a one-pass test using a pulse generator and a plasma-driven catalyst reactor, both of which are attachable to an air conditioner. Using a circulation test, the decrease in acetaldehyde concentration was measured in a closed vessel where the reactor had been placed. The removal efficiencies of particulate matter and acetaldehyde in the one-pass test (residence time of 10 ms) were 70% and 27%, respectively. In the circulation test, 98% of the suspended particles were collected after 2 min of operation and the acetaldehyde concentration decreased by 70% after 50 mins. It is believed that the TiO{sub 2} catalyst is excited by plasma-induced high-energy particles (electrons, photons, and metastable molecules), resulting in an enhanced pollutant removal. These test results indicate that the combination of plasma with TiO{sub 2} is a potential alternative in treating the pollutants in environmental tobacco smoke.

  7. Collection and analysis of NASA clean room air samples

    NASA Technical Reports Server (NTRS)

    Sheldon, L. S.; Keever, J.

    1985-01-01

    The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

  8. Project puts Clean Air worst case' rule to test

    SciTech Connect

    Krukowski, J.

    1994-09-01

    DuPont was one of eight companies with plants in the Kanawha Valley that took part in a pioneering effort to company with EPA's proposed Risk Management Programs (RMP) rule (40 CFR Part 68, or section 112(r) of the Clean Air Act). When the rule is finalized, perhaps in early 1996, about 140,000 facilities across the country will have three years to comply. The RMP proposes that companies estimate the potential effects of significant accidental releases'' of 77 acutely toxic chemicals, 63 flammable gases and volatile flammable liquids, and certain explosive substances. A list of the chemicals and threshold quantities was published in the Jan. 31 Federal Register. Companies also must compile and make public a five-year history of releases, and document their prevention and emergency response plans.

  9. Chicago Clean Air, Clean Water Project: Environmental Monitoring for a Healthy, Sustainable Urban Future

    SciTech Connect

    none, none; Tuchman, Nancy

    2015-11-11

    The U.S. Department of Energy awarded Loyola University Chicago and the Institute of Environmental Sustainability (IES) $486,000.00 for the proposal entitled “Chicago clean air, clean water project: Environmental monitoring for a healthy, sustainable urban future.” The project supported the purchase of analytical instruments for the development of an environmental analytical laboratory. The analytical laboratory is designed to support the testing of field water and soil samples for nutrients, industrial pollutants, heavy metals, and agricultural toxins, with special emphasis on testing Chicago regional soils and water affected by coal-based industry. Since the award was made in 2010, the IES has been launched (fall 2013), and the IES acquired a new state-of-the-art research and education facility on Loyola University Chicago’s Lakeshore campus. Two labs were included in the research and education facility. The second floor lab is the Ecology Laboratory where lab experiments and analyses are conducted on soil, plant, and water samples. The third floor lab is the Environmental Toxicology Lab where lab experiments on environmental toxins are conducted, as well as analytical tests conducted on water, soil, and plants. On the south end of the Environmental Toxicology Lab is the analytical instrumentation collection purchased from the present DOE grant, which is overseen by a full time Analytical Chemist (hired January 2016), who maintains the instruments, conducts analyses on samples, and helps to train faculty and undergraduate and graduate student researchers.

  10. Steam-oxygen and steam-water-oxygen methods for cleaning, passivation, and conservation of power engineering equipment

    NASA Astrophysics Data System (ADS)

    Man'kina, N. N.; Gol'Din, A. A.; Stolyarov, A. A.

    2008-07-01

    This publication presents results of efficient use of a developed technology for cleaning, passivating, and conservation of the heat-exchange equipment of industrial boilers and steam turbines of thermal power stations.

  11. 78 FR 16630 - Clean Air Act Grant: South Coast Air Quality Management District; Opportunity for Pubic Hearing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-18

    ... AGENCY 40 CFR Part 35 Clean Air Act Grant: South Coast Air Quality Management District; Opportunity for... proposed determination that the reduction in expenditures of non-Federal funds for the South Coast Air Quality Management District (SCAQMD) in support of its continuing air program under section 105 of...

  12. 77 FR 43074 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-23

    ... decree to address a lawsuit filed by Southern Alliance for Clean Energy, et al. v. EPA, No. 1:12-cv-00338-ESH (D.D.C). On or about March 2, 2012, Southern Alliance for Clean Energy, et al. filed a complaint... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency...

  13. A review of potential alternatives for air cleaning at the Hanford Waste Vitrification Plant

    SciTech Connect

    Sehmel, G.A.

    1990-07-01

    Pacific Northwest Laboratory conducted this review in support of the Hanford Waste Vitrification Plant (HWVP) being designed by Fluor Daniel Inc. for the US Department of Energy (DOE). The literature on air cleaning systems is reviewed to identify potential air cleaning alternatives that might be included in the design of HWVP. An overview of advantages/disadvantages of the various air cleaning technologies follows. Information and references are presented for the following potential air cleaning alternatives: deep-bed glass-fiber filters (DBGF), high-efficiency particulate air filters (HEPA), remote modular filter systems, high-efficiency mist eliminators (HEME), electrostatic precipitators, and the sand filter. Selected information is summarized for systems in the United States, Belgium, Japan, and West Germany. This review addresses high-capacity air cleaning systems currently used in the nuclear industry and emphasizes recent developments. 10 refs., 9 figs., 3 tabs.

  14. Bacterial communities on food court tables and cleaning equipment in a shopping mall.

    PubMed

    Dingsdag, S; Coleman, N V

    2013-08-01

    The food court at a shopping mall is a potential transfer point for pathogenic microbes, but to date, this environment has not been the subject of detailed molecular microbiological study. We used a combination of culture-based and culture-independent approaches to investigate the types and numbers of bacteria present on food court tables, and on a food court cleaning cloth. Bacteria were found at 10²-10⁵ c.f.u./m² on food court tables and 10¹⁰ c.f.u./m² on the cleaning cloth. Tag-pyrosequencing of amplified 16S rRNA genes revealed that the dominant bacterial types on the cleaning cloth were genera known to include pathogenic species (Stenotrophomonas, Aeromonas), and that these genera were also evident at lower levels on table surfaces, suggesting possible cross-contamination. The evidence suggests a public health threat is posed by bacteria in the food court, and that this may be due to cross-contamination between cleaning equipment and table surfaces.

  15. PremAir{trademark} catalyst systems: A new approach to clean air

    SciTech Connect

    Poles, T.; Anderson, D.R.; Durilla, M.; Heck, R.; Hoke, J.; Ober, R.; Rudy, W.

    1996-12-01

    PremAir{trademark} catalyst systems represents a new approach to air pollution control--one that focuses on destroying pollutants already in the air. PremAir is the trademark for a family of developmental catalysts capable of reducing ozone, carbon monoxide and potentially other pollutants in ambient air that comes into contact with catalyst-coated surfaces. The more air that comes into contact with the surface the more pollutants that can be destroyed. For this reason, Engelhard has focused its attention on heat-exchange equipment such as automotive radiators and air-conditioner condensers. It is because of advances in catalysis achieved at Engelhard that PremAir catalysts are active at the low temperatures found in these environments. In Los Angeles, which has the country`s worst smog problem, approximately one trillion cubic feet per day of air pass through car radiators and five trillion cubic feet per day pass through air conditioners. Most of the research, development and testing work performed to date has been on ozone catalysts and their application to car radiators. This paper discusses that work and the potential benefits associated with the PremAir technology. In addition, preliminary work on stationary applications of this new technology is discussed.

  16. Optimizing electric utility air toxics compliance with other titles of the Clean Air Act

    SciTech Connect

    Loeb, A.P.; South, D.W.

    1993-12-31

    This paper provides an overview of regulatory issues under Title III of the Clean Air Act Amendments that could affect electric utilities. Title III contains provisions relating to hazardous air pollutants (HAPs) and provides special treatment for electric utilities. Generally, this discussion documents that if utility toxic emissions are regulated, one of the chief difficulties confronting utilities will be the lack of coordination between Title III and other titles of the Act. The paper concludes that if the US Environmental Protection Agency (EPA) determines that regulation of utility HAPs is warranted under Title III, savings can be realized from flexible compliance treatment.

  17. Aerosols in clean and smoky air at Bozeman, Montana

    NASA Astrophysics Data System (ADS)

    Shaw, J. A.; Thomas, M.; Lathem, T. L.; Shaw, G. E.; Nenes, A.; Pust, N.; Repasky, K. S.

    2010-12-01

    The northern Rocky Mountain region of the United States is a natural laboratory for studying aerosols in a relatively uncontaminated environment punctuated by episodes of wildfire smoke. In autumn 2009, we conducted a field experiment at Montana State University in Bozeman, Montana to characterize the boundary layer aerosols as they transition from smoky periods to relatively clean background air. Physical and chemical properties of the aerosols were conducted, including high time resolution of Cloud Condensation Nuclei and inter comparison with AERONET data during times of deep atmospheric mixing. The key results of this experiment are: 1) the air in this northern Rocky Mountain location is surprisingly pristine with frequent aerosol size distributions devoid of a an accumulation mode; 2) periods of night-time growth of Aitken-mode aerosols were observed; 3) a persistent diurnal variation occurred, with upslope daytime winds bringing aerosols exhibiting moderate anthropogenic influence , and down slope nighttime winds bringing aerosols with weak accumulation mode; 4) the smoke aerosol was weakly soluble; and 5) satisfactory agreement was found between the inverted estimate of the fine mode aerosol from AERONET solar radiometry with that measured in situ.

  18. Saving energy and improving IAQ through application of advanced air cleaning technologies

    SciTech Connect

    Fisk, W.J; Destaillats, H.; Sidheswaran, M.A.

    2011-03-01

    In the future, we may be able use air cleaning systems and reduce rates of ventilation (i.e., reduce rates of outdoor air supply) to save energy, with indoor air quality (IAQ) remaining constant or even improved. The opportunity is greatest for commercial buildings because they usually have a narrower range of indoor pollutant sources than homes. This article describes the types of air cleaning systems that will be needed in commercial buildings.

  19. Methods for nuclear air-cleaning-system accident-consequence assessment

    SciTech Connect

    Andrae, R.W.; Bolstad, J.W.; Gregory, W.S.

    1982-01-01

    This paper describes a multilaboratory research program that is directed toward addressing many questions that analysts face when performing air cleaning accident consequence assessments. The program involves developing analytical tools and supportive experimental data that will be useful in making more realistic assessments of accident source terms within and up to the atmospheric boundaries of nuclear fuel cycle facilities. The types of accidents considered in this study includes fires, explosions, spills, tornadoes, criticalities, and equipment failures. The main focus of the program is developing an accident analysis handbook (AAH). We will describe the contents of the AAH, which include descriptions of selected nuclear fuel cycle facilities, process unit operations, source-term development, and accident consequence analyses. Three computer codes designed to predict gas and material propagation through facility air cleaning systems are described. These computer codes address accidents involving fires (FIRAC), explosions (EXPAC), and tornadoes (TORAC). The handbook relies on many illustrative examples to show the analyst how to approach accident consequence assessments. We will use the FIRAC code and a hypothetical fire scenario to illustrate the accident analysis capability.

  20. Control of Computer Room Air Conditioning using IT Equipment Sensors

    SciTech Connect

    Bell, Geoffrey C.; Storey, Bill; Patterson, Michael K.

    2009-09-30

    The goal of this demonstration was to show how sensors in IT equipment could be accessed and used to directly control computer room air conditioning. The data provided from the sensors is available on the IT network and the challenge for this project was to connect this information to the computer room air handler's control system. A control strategy was developed to enable separate control of the chilled water flow and the fans in the computer room air handlers. By using these existing sensors in the IT equipment, an additional control system is eliminated (or could be redundant) and optimal cooling can be provided saving significant energy. Using onboard server temperature sensors will yield significant energy reductions in data centers. Intel hosted the demonstration in its Santa Clara, CA data center. Intel collaborated with IBM, HP, Emerson, Wunderlich-Malec Engineers, FieldServer Technologies, and LBNL to install the necessary components and develop the new control scheme. LBNL also validated the results of the demonstration.

  1. 77 FR 39657 - Approval and Promulgation of Air Quality Implementation Plans; Washington; Determination of Clean...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-05

    ...; Determination of Clean Data for the 2006 24-Hour Fine Particulate Standard for the Tacoma, Pierce County... Air Quality Standard (NAAQS) has clean data for the 2006 24-hour PM 2.5 NAAQS. This proposed determination is based upon quality-assured, quality-controlled, and certified ambient air monitoring...

  2. 40 CFR 23.3 - Timing of Administrator's action under Clean Air Act.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 1 2013-07-01 2013-07-01 false Timing of Administrator's action under Clean Air Act. 23.3 Section 23.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GENERAL JUDICIAL REVIEW UNDER EPA-ADMINISTERED STATUTES § 23.3 Timing of Administrator's action under Clean Air...

  3. 40 CFR 23.3 - Timing of Administrator's action under Clean Air Act.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Timing of Administrator's action under Clean Air Act. 23.3 Section 23.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GENERAL JUDICIAL REVIEW UNDER EPA-ADMINISTERED STATUTES § 23.3 Timing of Administrator's action under Clean Air...

  4. 40 CFR 23.3 - Timing of Administrator's action under Clean Air Act.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Timing of Administrator's action under Clean Air Act. 23.3 Section 23.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GENERAL JUDICIAL REVIEW UNDER EPA-ADMINISTERED STATUTES § 23.3 Timing of Administrator's action under Clean Air...

  5. 40 CFR 23.3 - Timing of Administrator's action under Clean Air Act.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false Timing of Administrator's action under Clean Air Act. 23.3 Section 23.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GENERAL JUDICIAL REVIEW UNDER EPA-ADMINISTERED STATUTES § 23.3 Timing of Administrator's action under Clean Air...

  6. 45 CFR 2543.86 - Clean Air Act and the Federal Water Pollution Control Act.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Clean Air Act and the Federal Water Pollution... Water Pollution Control Act. Contracts and subgrants of amounts in excess of $100,000 shall contain a... regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401 et seq.) and the Federal Water...

  7. 14 CFR 1274.926 - Clean Air-Water Pollution Control Acts.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 5 2013-01-01 2013-01-01 false Clean Air-Water Pollution Control Acts...-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative... 91-604) and section 308 of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251 et...

  8. 45 CFR 2543.86 - Clean Air Act and the Federal Water Pollution Control Act.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 4 2011-10-01 2011-10-01 false Clean Air Act and the Federal Water Pollution... Water Pollution Control Act. Contracts and subgrants of amounts in excess of $100,000 shall contain a... regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401 et seq.) and the Federal Water...

  9. 45 CFR 2543.86 - Clean Air Act and the Federal Water Pollution Control Act.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 4 2012-10-01 2012-10-01 false Clean Air Act and the Federal Water Pollution... Water Pollution Control Act. Contracts and subgrants of amounts in excess of $100,000 shall contain a... regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401 et seq.) and the Federal Water...

  10. 14 CFR 1274.926 - Clean Air-Water Pollution Control Acts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Clean Air-Water Pollution Control Acts...-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative... 91-604) and section 308 of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251 et...

  11. 14 CFR 1274.926 - Clean Air-Water Pollution Control Acts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 5 2012-01-01 2012-01-01 false Clean Air-Water Pollution Control Acts...-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative... 91-604) and section 308 of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251 et...

  12. 45 CFR 2543.86 - Clean Air Act and the Federal Water Pollution Control Act.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 4 2014-10-01 2014-10-01 false Clean Air Act and the Federal Water Pollution... Water Pollution Control Act. Contracts and subgrants of amounts in excess of $100,000 shall contain a... regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401 et seq.) and the Federal Water...

  13. 14 CFR § 1274.926 - Clean Air-Water Pollution Control Acts.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 5 2014-01-01 2014-01-01 false Clean Air-Water Pollution Control Acts. Â...-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative... 91-604) and section 308 of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251 et...

  14. 45 CFR 2543.86 - Clean Air Act and the Federal Water Pollution Control Act.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 4 2013-10-01 2013-10-01 false Clean Air Act and the Federal Water Pollution... Water Pollution Control Act. Contracts and subgrants of amounts in excess of $100,000 shall contain a... regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401 et seq.) and the Federal Water...

  15. 75 FR 16461 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-01

    ... AGENCY Proposed Settlement Agreement, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency... accordance with section 113(g) of the Clean Air Act, as amended (``CAA'' or ``Act''), 42 U.S.C. 7413(g... title V of the Act, 42 U.S.C. 7661 et seq., to RRI Energy Mid-Atlantic's Portland Generating Station...

  16. 75 FR 42132 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-20

    ... of Lodging of Consent Decree Under the Clean Air Act Pursuant to 28 CFR 50.7, notice is hereby given... injunctive relief under Section 113(b) of the Clean Air Act (the Act), 42 U.S.C. 7413(b), for failure to... earthmoving, failure to operate a water application system while conducting earthmoving, and failure...

  17. 77 FR 47381 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-08

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Settlement Agreement, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency... accordance with section 113(g) of the Clean Air Act, as amended (``Act''), 42 U.S.C. 7413(g), notice...

  18. 78 FR 48161 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-07

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (CAA or the Act), notice is hereby given of a...

  19. 76 FR 45793 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-01

    ... From the Federal Register Online via the Government Publishing Office ] ENVIRONMENTAL PROTECTION AGENCY Proposed Settlement Agreement, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency... accordance with section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), 42 U.S.C....

  20. 75 FR 67719 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-03

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency... section 113(g) of the Clean Air Act, as amended (CAA or the Act), 42 U.S.C. 7413(g), notice is...

  1. 40 CFR 23.3 - Timing of Administrator's action under Clean Air Act.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Timing of Administrator's action under Clean Air Act. 23.3 Section 23.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GENERAL JUDICIAL REVIEW UNDER EPA-ADMINISTERED STATUTES § 23.3 Timing of Administrator's action under Clean Air...

  2. 76 FR 51030 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-17

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), 42 U.S.C. 7413(g), notice...

  3. 76 FR 81930 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-29

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Settlement Agreement, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency... accordance with section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), notice is...

  4. 76 FR 56757 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-14

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA''), 42 U.S.C. 7413(g), notice is hereby given of...

  5. 78 FR 40140 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-03

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), notice is hereby given of...

  6. 78 FR 21419 - Notice of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-10

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF JUSTICE Notice of Proposed Consent Decree Under the Clean Air Act On April 4, 2013, the Department of Justice lodged... Processed Meats, Inc. The United States filed this lawsuit under the Clean Air Act (CAA), 42 U.S.C....

  7. 75 FR 22786 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-30

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), 42 U.S.C. 7413(g), notice...

  8. 75 FR 61774 - Notice of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-06

    ... of Proposed Consent Decree Under the Clean Air Act Notice is hereby given that on September 28, 2010... Consent Decree in this Clean Air Act enforcement actions against Murphy Oil USA, Inc. (``Murphy... Louisiana asserted in a complaint filed together with the Consent Decree, under Section 113(b) of the...

  9. 77 FR 281 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-04

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... 2, 2011, EPA provided notice in accordance with section 113(g) of the Clean Air Act, as...

  10. 75 FR 24946 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-06

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA''), 42 U.S.C. 7413(g), notice is hereby given of...

  11. 75 FR 38520 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-02

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (CAA), 42 U.S.C. 7413(g), notice is hereby given of...

  12. 76 FR 5609 - Notice of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-01

    ... of Proposed Consent Decree Under the Clean Air Act Notice is hereby given that on January 26, 2011, a... United States et al. v. HOVENSA L.L.C., Civil Action No. 1:11-cv-6. The Consent Decree in this Clean Air... Agency, asserted in a complaint filed together with the Consent Decree, under section 113(b) of the...

  13. 76 FR 75544 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-02

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), 42 U.S.C. 7413(g), notice...

  14. 76 FR 75545 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-02

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), 42 U.S.C. 7413(g), notice...

  15. 78 FR 53143 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-28

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), notice is hereby given of...

  16. 77 FR 46757 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-06

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA''), notice is hereby given of a proposed...

  17. 77 FR 56840 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-14

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), 42 U.S.C. 7413(g), notice...

  18. 77 FR 67814 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-14

    ... Pollution Affecting Visibility and Best Available Retrofit Technology Determinations,'' 76 FR 81,728 (Dec... AGENCY Proposed Settlement Agreement, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency... accordance with section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), notice is...

  19. 77 FR 66978 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-08

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA''), notice is hereby given of a proposed...

  20. 75 FR 38519 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-02

    ... From the Federal Register Online via the Government Publishing Office ] ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (CAA), 42 U.S.C. 7413(g), notice is hereby given of...

  1. 76 FR 58808 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-22

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA''), 42 U.S.C. 7413(g), notice is hereby given of...

  2. 77 FR 21834 - Airborne Radar Altimeter Equipment (For Air Carrier Aircraft)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-11

    ... Federal Aviation Administration Airborne Radar Altimeter Equipment (For Air Carrier Aircraft) AGENCY..., Airborne Radar Altimeter Equipment (For Air Carrier Aircraft). SUMMARY: This is a confirmation notice of the cancellation of TSO-C67, Airborne Radar Altimeter Equipment (For Air Carrier Aircraft). The...

  3. Precision cleaning verification of fluid components by air/water impingement and total carbon analysis

    NASA Technical Reports Server (NTRS)

    Barile, Ronald G.; Fogarty, Chris; Cantrell, Chris; Melton, Gregory S.

    1994-01-01

    NASA personnel at Kennedy Space Center's Material Science Laboratory have developed new environmentally sound precision cleaning and verification techniques for systems and components found at the center. This technology is required to replace existing methods traditionally employing CFC-113. The new patent-pending technique of precision cleaning verification is for large components of cryogenic fluid systems. These are stainless steel, sand cast valve bodies with internal surface areas ranging from 0.2 to 0.9 sq m. Extrapolation of this technique to components of even larger sizes (by orders of magnitude) is planned. Currently, the verification process is completely manual. In the new technique, a high velocity, low volume water stream impacts the part to be verified. This process is referred to as Breathing Air/Water Impingement and forms the basis for the Impingement Verification System (IVS). The system is unique in that a gas stream is used to accelerate the water droplets to high speeds. Water is injected into the gas stream in a small, continuous amount. The air/water mixture is then passed through a converging/diverging nozzle where the gas is accelerated to supersonic velocities. These droplets impart sufficient energy to the precision cleaned surface to place non-volatile residue (NVR) contaminants into suspension in the water. The sample water is collected and its NVR level is determined by total organic carbon (TOC) analysis at 880 C. The TOC, in ppm carbon, is used to establish the NVR level. A correlation between the present gravimetric CFC113 NVR and the IVS NVR is found from experimental sensitivity factors measured for various contaminants. The sensitivity has the units of ppm of carbon per mg/sq ft of contaminant. In this paper, the equipment is described and data are presented showing the development of the sensitivity factors from a test set including four NVRs impinged from witness plates of 0.05 to 0.75 sq m.

  4. Precision Cleaning Verification of Fluid Components by Air/Water Impingement and Total Carbon Analysis

    NASA Technical Reports Server (NTRS)

    Barile, Ronald G.; Fogarty, Chris; Cantrell, Chris; Melton, Gregory S.

    1995-01-01

    NASA personnel at Kennedy Space Center's Material Science Laboratory have developed new environmentally sound precision cleaning and verification techniques for systems and components found at the center. This technology is required to replace existing methods traditionally employing CFC-113. The new patent-pending technique of precision cleaning verification is for large components of cryogenic fluid systems. These are stainless steel, sand cast valve bodies with internal surface areas ranging from 0.2 to 0.9 m(exp 2). Extrapolation of this technique to components of even larger sizes (by orders of magnitude) is planned. Currently, the verification process is completely manual. In the new technique, a high velocity, low volume water stream impacts the part to be verified. This process is referred to as Breathing Air/Water Impingement and forms the basis for the Impingement Verification System (IVS). The system is unique in that a gas stream is used to accelerate the water droplets to high speeds. Water is injected into the gas stream in a small, continuous amount. The air/water mixture is then passed through a converging-diverging nozzle where the gas is accelerated to supersonic velocities. These droplets impart sufficient energy to the precision cleaned surface to place non-volatile residue (NVR) contaminants into suspension in the water. The sample water is collected and its NVR level is determined by total organic carbon (TOC) analysis at 880 C. The TOC, in ppm carbon, is used to establish the NVR level. A correlation between the present gravimetric CFC-113 NVR and the IVS NVR is found from experimental sensitivity factors measured for various contaminants. The sensitivity has the units of ppm of carbon per mg-ft(exp 2) of contaminant. In this paper, the equipment is described and data are presented showing the development of the sensitivity factors from a test set including four NVR's impinged from witness plates of 0.05 to 0.75 m(exp 2).

  5. BACT analysis under the Clean Air Act's PCD program

    SciTech Connect

    Simms, P.; Walke, J.

    2006-11-15

    Before a company may build a new major industrial source of air pollution, or make modifications to an existing major source in the USA it must apply for and receive a Clean Air Act (CAA) Prevention of Significant Deterioration (PSD) permit. State environmental agencies typically issue such permits, either under state law or by exercising delegated authority to implement the federal PSD program. To fully comply with the CAA, the emissions limits identified as BACT must incorporate consideration of more than just add-on emissions control technology, they must also reflect appropriate considerations of fuel quality (e.g. low-sulfur coal) and process changes (e.g. advanced combustion techniques) as a means of controlling emissions, and must consider the other environmental and public welfare benefits of the identified emissions control options. Several states including New Mexico and Illinois have already determined that innovated technologies, such as Integrated Gasification Combined Cycle (IGCC), must be considered in connection with the BACT analysis for new coal-fired power plants. Even the notion that BACT is categorically limited in scope to the general type of facility proposed is contrary to EPA precedent. For example, the Environmental Appeals Board (EAB) has explained that permitting authorities retain the discretion under the definition of BACT to require dramatically different facility designs (e.g. a natural gas plant instead of a coal-fired power plant). The best advice for any permit applicant is to include in the BACT analysis a careful and honest examination of better performing alternative processes and/or innovative combustion techniques and to aggressively pursue such options wherever feasible. 17 refs.

  6. Highlights of the Clean Air Act Amendments of 1990

    SciTech Connect

    Lee, B.

    1991-01-01

    The amendments to the Clean Air Act provide for operating permits for stationary sources of pollution, marking a change that is comparable to federal water pollution regulations. The bill addresses acid rain emissions and will phase out production of chemicals contributing to depletion of the stratospheric ozone layer. A major new concept incorporated into the emission limits established by law is a system of tradeable emissions credits. If a facility reduces emissions below the standard or ahead of the timetable set by law, emissions credits are earned that can be applied to future emissions or sold to another facility. The bill also provides strict deadlines for the EPA to meet in promulgating the regulations. These deadlines will seriously strain the personnel and financial resources of the agency. Perhaps the most significant of the miscellaneous items in the law is a provision for extended unemployment benefits under the Job Training Partnership Act for workers who lose their jobs because of the law's provisions. However, this is contingent on the displaced workers' seeking job retraining.

  7. The Clean Air Act impacts on rail coal

    SciTech Connect

    Sharp, R.G. )

    1991-03-01

    These factors are examined in this article. In November 1990, President Bush signed the Clean Air Act amendments of 1990 into law. Title IV, concerning acid rain control, calls for a two-phase reduction in power plant sulfur-dioxide emissions, culminating in a nationwide cap after the year 2000. A large part of this reduction will be obtained through substituting low-sulfur coals for the higher-sulfur fuels now used. Most commentators have characterized this legislation as a boon for low-sulfur coal producers and the railroads serving them. If, as projected, up to one-eighth of existing coal-burning plants shift to more distant suppliers, a surge in rail traffic would ensue. Whether this traffic originates at eastern or western mines, rail carriers would obtain longer hauls and greater coal volumes. We have examined the rail transport implications of the amendments and found that the potential rail benefits may be exaggerated. Although traffic volume will grow, margins on some new traffic are likely to be eroded by continued rate competition and reduced productivity. To satisfy coal transport needs in the 1990s, factors that challenge rail productivity must be recognized and resolved.

  8. Air Pollution Studies in Metromanila and Catalysis Technology Towards Clean Air Philippines

    NASA Astrophysics Data System (ADS)

    Gallardo, S. M.

    - Considerable air quality and emission data gathered in Metropolitan Manila (MM) led to the development of automobile exhaust treatment catalysts as well as their continued improvement. Findings of a 5-year (1993-1998) collaborative work on the development of base metal oxide catalysts for automobile exhaust are summarized here. One study in 1991 reveals an average 16% increase in the number of motor vehicles in MM where 16% are new and the rest are old ones. Another study in 1992 shows the CO and hydrocarbon emission levels from different types of motor vehicles in MM as a function of the age of the vehicle, type of fuel, and the operating condition. Reports of the Department of Environment and Natural Resources (DENR) and other related studies also provided data showing the quality of air in MM. Currently, there are several requirements to further improve the catalyst performance towards the reduction of NOX and to develop catalyst-sorbent for simultaneous NOX-SOX removal. This is so because of the present condition of rain acidification that is found in certain places in MM. These air quality and emission data are needed not only to establish practical emission standards for motor vehicles and the stationary industries and power plants but also in the development of technologies for air pollution control and other clean technologies for cleaner air in the country.

  9. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Reconstruction is Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only Wood Waste, Clean... only wood waste, clean lumber, and yard waste? (a) Within 60 days after your air curtain...

  10. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Reconstruction is Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only Wood Waste, Clean... only wood waste, clean lumber, and yard waste? (a) Within 60 days after your air curtain...

  11. 40 CFR 52.36 - What are the requirements of the Federal Implementation Plans (FIPs) for the Clean Air Interstate...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Federal Implementation Plans (FIPs) for the Clean Air Interstate Rule (CAIR) relating to emissions of... What are the requirements of the Federal Implementation Plans (FIPs) for the Clean Air Interstate Rule... part 97 of this chapter constitute the Clean Air Interstate Rule Federal Implementation Plan...

  12. 40 CFR 52.36 - What are the requirements of the Federal Implementation Plans (FIPs) for the Clean Air Interstate...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Federal Implementation Plans (FIPs) for the Clean Air Interstate Rule (CAIR) relating to emissions of... What are the requirements of the Federal Implementation Plans (FIPs) for the Clean Air Interstate Rule... part 97 of this chapter constitute the Clean Air Interstate Rule Federal Implementation Plan...

  13. 40 CFR 22.34 - Supplemental rules governing the administrative assessment of civil penalties under the Clean Air...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... administrative assessment of civil penalties under the Clean Air Act. 22.34 Section 22.34 Protection of... Clean Air Act. (a) Scope. This section shall apply, in conjunction with §§ 22.1 through 22.32, in...) of the Clean Air Act, as amended (42 U.S.C. 7413(d), 7524(c), 7545(d), and 7547(d))....

  14. 40 CFR 22.34 - Supplemental rules governing the administrative assessment of civil penalties under the Clean Air...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... administrative assessment of civil penalties under the Clean Air Act. 22.34 Section 22.34 Protection of... Clean Air Act. (a) Scope. This section shall apply, in conjunction with §§ 22.1 through 22.32, in...) of the Clean Air Act, as amended (42 U.S.C. 7413(d), 7524(c), 7545(d), and 7547(d))....

  15. 40 CFR 22.34 - Supplemental rules governing the administrative assessment of civil penalties under the Clean Air...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... administrative assessment of civil penalties under the Clean Air Act. 22.34 Section 22.34 Protection of... Clean Air Act. (a) Scope. This section shall apply, in conjunction with §§ 22.1 through 22.32, in...) of the Clean Air Act, as amended (42 U.S.C. 7413(d), 7524(c), 7545(d), and 7547(d))....

  16. 40 CFR 22.34 - Supplemental rules governing the administrative assessment of civil penalties under the Clean Air...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... administrative assessment of civil penalties under the Clean Air Act. 22.34 Section 22.34 Protection of... Clean Air Act. (a) Scope. This section shall apply, in conjunction with §§ 22.1 through 22.32, in...) of the Clean Air Act, as amended (42 U.S.C. 7413(d), 7524(c), 7545(d), and 7547(d))....

  17. 40 CFR 49.7 - Request by an Indian tribe for eligibility determination and Clean Air Act program approval.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... eligibility determination and Clean Air Act program approval. 49.7 Section 49.7 Protection of Environment... MANAGEMENT Tribal Authority § 49.7 Request by an Indian tribe for eligibility determination and Clean Air Act... it meets the eligibility requirements of § 49.6 for Clean Air Act program approval. The...

  18. 40 CFR 49.7 - Request by an Indian tribe for eligibility determination and Clean Air Act program approval.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... eligibility determination and Clean Air Act program approval. 49.7 Section 49.7 Protection of Environment... MANAGEMENT Tribal Authority § 49.7 Request by an Indian tribe for eligibility determination and Clean Air Act... it meets the eligibility requirements of § 49.6 for Clean Air Act program approval. The...

  19. 40 CFR 49.7 - Request by an Indian tribe for eligibility determination and Clean Air Act program approval.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... eligibility determination and Clean Air Act program approval. 49.7 Section 49.7 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE TRIBAL CLEAN AIR ACT AUTHORITY Tribal Authority § 49.7 Request by an Indian tribe for eligibility determination and Clean Air Act program...

  20. 40 CFR 49.7 - Request by an Indian tribe for eligibility determination and Clean Air Act program approval.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... eligibility determination and Clean Air Act program approval. 49.7 Section 49.7 Protection of Environment... MANAGEMENT Tribal Authority § 49.7 Request by an Indian tribe for eligibility determination and Clean Air Act... it meets the eligibility requirements of § 49.6 for Clean Air Act program approval. The...

  1. 40 CFR 52.36 - What are the requirements of the Federal Implementation Plans (FIPs) for the Clean Air Interstate...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Federal Implementation Plans (FIPs) for the Clean Air Interstate Rule (CAIR) relating to emissions of... What are the requirements of the Federal Implementation Plans (FIPs) for the Clean Air Interstate Rule... part 97 of this chapter constitute the Clean Air Interstate Rule Federal Implementation Plan...

  2. 3 CFR - State of California Request for Waiver Under 42 U.S.C. 7543(b), the Clean Air Act

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....C. 7543(b), the Clean Air Act Presidential Documents Other Presidential Documents Memorandum of January 26, 2009 State of California Request for Waiver Under 42 U.S.C. 7543(b), the Clean Air Act Memorandum for the Administrator of the Environmental Protection Agency Under the Clean Air Act (42...

  3. Healy Clean Coal Project, Healy FCM testing at Niro Air Pollution Control Pilot Facility. Final report

    SciTech Connect

    Not Available

    1992-10-01

    In September, 1991, pilot testing was performed at the Niro Air Pollution Control Pilot Plant in Copenhagen, Denmark in support of the Healy Clean Coal Project (HCCP), which is part of the United States Department of Energy (DOE) Clean Coal Technology Ill Program. The HCCP is a proposed new coal fired power plant, located in Healy, Alaska. It consists of a TRW entrained combustion system, coupled with a limestone calciner, which operates in synergism with a Joy/Niro Spray Dryer Absorber (SDA) system equipped with a lime activation system that is designed to increase the utilization of the calcined product for sulfur capture in the SDA. The pilot tests, which were funded by the United States Department of Energy (DOE) and the Alaska Industrial Development and Export Authority (AIDEA), were conducted to investigate the characteristics of the TRW combustor/limestone calciner product, referred to as Flash Calcined Material (FCM) with respect to its ability to remove S0{sub 2 } in the Joy/Niro Activated Recycle SDA system. This report describes the pilot facility, the test objectives and methods, and the results of the tests.

  4. Healy Clean Coal Project, Healy FCM testing at Niro Air Pollution Control Pilot Facility

    SciTech Connect

    Not Available

    1992-10-01

    In September, 1991, pilot testing was performed at the Niro Air Pollution Control Pilot Plant in Copenhagen, Denmark in support of the Healy Clean Coal Project (HCCP), which is part of the United States Department of Energy (DOE) Clean Coal Technology Ill Program. The HCCP is a proposed new coal fired power plant, located in Healy, Alaska. It consists of a TRW entrained combustion system, coupled with a limestone calciner, which operates in synergism with a Joy/Niro Spray Dryer Absorber (SDA) system equipped with a lime activation system that is designed to increase the utilization of the calcined product for sulfur capture in the SDA. The pilot tests, which were funded by the United States Department of Energy (DOE) and the Alaska Industrial Development and Export Authority (AIDEA), were conducted to investigate the characteristics of the TRW combustor/limestone calciner product, referred to as Flash Calcined Material (FCM) with respect to its ability to remove S0[sub 2 ] in the Joy/Niro Activated Recycle SDA system. This report describes the pilot facility, the test objectives and methods, and the results of the tests.

  5. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy ? FY11 Final Report

    SciTech Connect

    Sidheswaran, Meera; Destaillats, Hugo; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William J.

    2011-10-31

    The research carried out in this project focuses on developing novel volatile organic compounds (VOCs) air cleaning technologies needed to enable energy-saving reductions in ventilation rates. we targeted a VOC air cleaning system that could enable a 50% reduction in ventilation rates. In a typical commercial HVAC system that provides a mixture of recirculated and outdoor air, a VOC air cleaner in the supply airstream must have a 15% to 20% VOC removal efficiency to counteract a 50% reduction in outdoor air supply.

  6. Reticle storage in microenvironments with extreme clean dry air

    NASA Astrophysics Data System (ADS)

    Gettel, Astrid; Glüer, Detlev; Honold, Alfred

    2012-11-01

    Haze formation on the patterned metal surface of reticles is a known problem for IC manufacturers that can impact device yield and increase operational costs due to the need for more frequent cleaning of the reticles. Storage of reticles in an ultraclean environment can reduce haze formation and reduce operational costs. We examined the contamination levels of a new type of reticle stocker that stores reticles in microenvironments which are continuously purged with extreme clean dry air (XCDA). Each microenvironment consists of twelve vertically stacked reticle storage slots which can be opened at any slot. The design of the microenvironment includes an XCDA supply that provides a homogeneous horizontal flow of XCDA between the reticles. Figure 1. Reduction of contamination levels inside the storage microenvironment as a function of XCDA flow rate. As shown in Fig. 1, continuous XCDA purge reduces the contaminant levels inside the microenvironment. The amount of reduction depends on the XCDA purge flow rate and the chemical species. Volatile organic substances can be reduced by more than two orders of magnitude. Humidity is reduced less because the plastic material of the storage microenvironment incorporates water in its matrix and can release moisture to the extremely dry atmosphere. Chemical filters applied to mini- or microenvironments typically reduce the contaminant levels only by 95-99% and do not reduce the humidity. To pick and place reticles, the reticle storage microenvironment must be opened. The transient contaminant levels inside the empty microenvironment show an increase at the moment when the microenvironment is opened. Under the given conditions, the microenvironment returns to equilibrium levels with a time constant of 105 seconds (see Fig. 2). Similar dynamic response was measured for IPA and acetone. Figure 2. Transient humidity when the storage microenvironment was opened for reticle handling. The impact of handling on reticles stored inside

  7. Keeping the Air Clean and Safe: An Anthrax Smoke Detector

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Scientists at work in the Planetary Protection division at NASA s Jet Propulsion Laboratory (JPL) sterilize everything before blasting it to the Red Planet. They take great pains to ensure that all spacecraft are void of bacterial life, especially the microscopic bacteria that can live hundreds of years in their spore states. No one is quite sure what Earthly germs would do on Mars, but scientists agree that it is safest to keep the Martian terrain as undisturbed as possible. Errant Earth germs would also render useless the instruments placed on exploration rovers to look for signs of life, as the life that they registered would be life that came with them from Earth. A team at JPL, headed by Dr. Adrian Ponce, developed a bacterial spore-detection system that uses a simple and robust chemical reaction that visually alerts Planetary Protection crews. It is a simple air filter that traps micron-sized bacterial spores and then submits them to the chemical reaction. When the solution is then viewed under an ultraviolet light, the mixture will glow green if it is contaminated by bacteria. Scientists can then return to the scrubbing and cleaning stages of the sterilization process to remove these harmful bacteria. The detection system is the space-bound equivalent of having your hands checked for cleanliness before being allowed to the table; and although intended to keep terrestrial germs from space, this technology has awesome applications here on Mother Earth. The bacterial spore-detection unit can recognize anthrax and other harmful, spore-forming bacteria and alert people of the impending danger. As evidenced in the anthrax mailings of fall 2001 in the United States, the first sign of anthrax exposure was when people experienced flu-like symptoms, which unfortunately, can take as much as a week to develop after contamination. Anthrax cost 5 people their lives and infected 19 others; and the threat of bioterrorism became a routine concern, with new threats popping up

  8. Air emission control equipment - the new challenge for equpiment suppliers

    SciTech Connect

    Lobb, F.H.

    1997-12-31

    The combination of Title V, the CAM Rule and the Credible Evidence Rule demand industrial sites view the selection and operation of emission control devices in a whole new light. No longer can users see these devices as detached end of pipe pieces of equipment essentially purchased off lowest bid. These regulatory changes force plants to fully integrate the operation of these devices into their process control systems and instrumentation. And this is specifically EPA`s stated intent. EPA believes that by forcing sites to exercise the same knowledge and attention to air emissions that they do to operate their production processes, emissions will undergo a natural reduction across the country. Process and operational data that historically has been the sole province of sites becomes public. And compliance with state defined requirements must be demonstrated essentially continuously. This paper explores the new approach to compliance and provides insight through specific field examples/installations of emission control equipment. The author seeks to promote understanding through discussion of these significant regulatory changes.

  9. VERIFICATION TESTING OF TECHNOLOGIES TO CLEAN OR FILTER VENTILATION AIR

    EPA Science Inventory

    Because of the importance of indoor air quality, Research Triangle Institute's Air Pollution Control Technology is adding indoor air products as a new technology category available for testing. This paper discusses RTI's participation in previous Environmental Technology Verifica...

  10. 10 CFR 429.43 - Commercial heating, ventilating, air conditioning (HVAC) equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Commercial heating, ventilating, air conditioning (HVAC... Commercial heating, ventilating, air conditioning (HVAC) equipment. (a) Sampling plan for selection of units... each basic model of commercial heating, ventilating, air conditioning (HVAC) equipment, efficiency...

  11. 10 CFR 429.43 - Commercial heating, ventilating, air conditioning (HVAC) equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Commercial heating, ventilating, air conditioning (HVAC... Commercial heating, ventilating, air conditioning (HVAC) equipment. (a) Sampling plan for selection of units... each basic model of commercial heating, ventilating, air conditioning (HVAC) equipment, efficiency...

  12. 48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... and Air Conditioners. 52.223-12 Section 52.223-12 Federal Acquisition Regulations System FEDERAL... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor...

  13. 48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and Air Conditioners. 52.223-12 Section 52.223-12 Federal Acquisition Regulations System FEDERAL... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor...

  14. 48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... and Air Conditioners. 52.223-12 Section 52.223-12 Federal Acquisition Regulations System FEDERAL... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor...

  15. 48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... and Air Conditioners. 52.223-12 Section 52.223-12 Federal Acquisition Regulations System FEDERAL... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor...

  16. 48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and Air Conditioners. 52.223-12 Section 52.223-12 Federal Acquisition Regulations System FEDERAL... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor...

  17. 76 FR 26768 - Notice of Lodging of a Consent Decree Under The Clean Water Act, The Clean Air Act, and The...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-09

    ... of Lodging of a Consent Decree Under The Clean Water Act, The Clean Air Act, and The Federal Pipeline Safety Laws Notice is hereby given that on May 3, 2011, a proposed Consent Decree in United States v. BP... relief for violations of the Clean Water Act, 33 U.S.C. 1311, 1319, 1321, as amended by the Oil...

  18. Effectiveness of HVAC duct cleaning procedures in improving indoor air quality.

    PubMed

    Ahmad, I; Tansel, B; Mitrani, J D

    2001-12-01

    Indoor air quality has become one of the most serious environmental concerns as an average person spends about 22 hr indoors on a daily basis. The study reported in this article, was conducted to determine the effectiveness of three commercial HVAC (Heating Ventilation Air Conditioning) duct cleaning processes in reducing the level of airborne particulate matter and viable bioaerosols. The three HVAC sanitation processes were: (1) Contact method (use of conventional vacuum cleaning of interior duct surfaces); (2) Air sweep method (use of compressed air to dislodging dirt and debris); (3) Rotary brush method (insertion of a rotary brush into the ductwork to agitate and dislodge the debris). Effectiveness of these sanitation processes was evaluated in terms of airborne particulate and viable bioaerosol concentrations in residential homes. Eight identical homes were selected in the same neighborhood. Two homes were cleaned using each procedure and two were used as controls. It was found that both particle count readings and bioaerosol concentrations were higher when cleaning was being performed than before or after cleaning, which suggests that dirt, debris and other pollutants may become airborne as a result of disturbances caused by the cleaning processes. Particle count readings at 0.3 micron size were found to have increased due to cigarette smoking. Particle counts at 1.0 micron size were reduced due to HVAC duct cleaning. Post-level bioaerosol concentrations, taken two days after cleaning, were found to be lower than the pre-level concentrations suggesting that the cleaning procedures were effective to some extent. Homes cleaned with the Air Sweep procedure showed the highest degree of reduction in bioaerosol concentration among the three procedures investigated.

  19. Radical observations during the Clean air for London project

    NASA Astrophysics Data System (ADS)

    Whalley, L. K.; Stone, D.; Clancy, N.; Lee, J. D.; Laufs, S.; Kleffmann, J.; Heard, D. E.

    2012-12-01

    With greater than 50 % of the global population residing in urban conurbations, poor urban air quality has a demonstrable effect on human health. OH and HO2 radicals, (collectively termed HOx) together with RO2 radicals, mediate virtually all of the oxidative chemistry in the atmosphere, being responsible for the transformation of primary emissions into secondary pollutants such as NO2, O3 and particulates. Understanding the chemistry of free-radicals in the atmosphere is essential in improving predictions of the lifetimes of pollutants and spatial scales of their transport within urban areas. Results from earlier field campaigns in urban and polluted regions have demonstrated the significance of HONO photolysis and alkene ozonolysis in the production of HOx radicals. In many cases, however, measurements of HONO have not been made, reducing the ability to evaluate model successes for OH in these environments. Here we present measurements of OH, HO2, RO2 and OH reactivity taken during the wintertime (January - February, 2012) and summertime (July - August, 2012) as part of the Clean air for London (ClearfLo) project in London. RO2 was detected using a newly developed flow-reactor laser-induced fluorescence technique which is able to discriminate between HO2 and organic peroxy radicals [1]. Low concentrations of radicals were observed during the wintertime, midday [OH], [HO2] and [RO2] were ~ 0.04, 0.8 and 1.5 pptv respectively, comparable to observations of radicals at other urban locations in winter [2,3,4], and which displayed a negative correlation with NO concentrations. OH reactivity was high and largely tracked the diurnal profiles of NOx and CO, with the highest reactivity ~100 s-1 observed during the morning rush hour. Analysis of factors controlling OH concentrations during the wintertime suggests that the formation of OH from the photolysis of O3 and subsequent reaction of O(1D) with H2O is a minor contribution both under high and low NOx conditions owing

  20. Air toxics provisions of the Clean Air Act: Potential impacts on energy

    SciTech Connect

    Hootman, H.A.; Vernet, J.E.

    1991-11-01

    This report provides an overview of the provisions of the Clean Air Act and its Amendments of 1990 that identify hazardous air pollutant (HAP) emissions and addresses their regulation by the US Environmental Protection Agency (EPA). It defines the major energy sector sources of these HAPs that would be affected by the regulations. Attention is focused on regulations that would cover coke oven emissions; chromium emission from industrial cooling towers and the electroplating process; HAP emissions from tank vessels, asbestos-related activities, organic solvent use, and ethylene oxide sterilization; and emissions of air toxics from municipal waste combustors. The possible implications of Title III regulations for the coal, natural gas, petroleum, uranium, and electric utility industries are examined. The report discusses five major databases of HAP emissions: (1) TRI (EPA`s Toxic Release Inventory); (2) PISCES (Power Plant Integrated Systems: Chemical Emissions Studies developed by the Electric Power Research Institute); (3) 1985 Emissions Inventory on volatile organic compounds (used for the National Acid Precipitation Assessment Program); (4) Particulate Matter Species Manual (EPA); and (5) Toxics Emission Inventory (National Aeronautics and Space Administration). It also offers information on emission control technologies for municipal waste combustors.

  1. Air toxics provisions of the Clean Air Act: Potential impacts on energy

    SciTech Connect

    Hootman, H.A.; Vernet, J.E.

    1991-11-01

    This report provides an overview of the provisions of the Clean Air Act and its Amendments of 1990 that identify hazardous air pollutant (HAP) emissions and addresses their regulation by the US Environmental Protection Agency (EPA). It defines the major energy sector sources of these HAPs that would be affected by the regulations. Attention is focused on regulations that would cover coke oven emissions; chromium emission from industrial cooling towers and the electroplating process; HAP emissions from tank vessels, asbestos-related activities, organic solvent use, and ethylene oxide sterilization; and emissions of air toxics from municipal waste combustors. The possible implications of Title III regulations for the coal, natural gas, petroleum, uranium, and electric utility industries are examined. The report discusses five major databases of HAP emissions: (1) TRI (EPA's Toxic Release Inventory); (2) PISCES (Power Plant Integrated Systems: Chemical Emissions Studies developed by the Electric Power Research Institute); (3) 1985 Emissions Inventory on volatile organic compounds (used for the National Acid Precipitation Assessment Program); (4) Particulate Matter Species Manual (EPA); and (5) Toxics Emission Inventory (National Aeronautics and Space Administration). It also offers information on emission control technologies for municipal waste combustors.

  2. Can commonly-used fan-driven air cleaning technologies improve indoor air quality? A literature review

    NASA Astrophysics Data System (ADS)

    Zhang, Yinping; Mo, Jinhan; Li, Yuguo; Sundell, Jan; Wargocki, Pawel; Zhang, Jensen; Little, John C.; Corsi, Richard; Deng, Qihong; Leung, Michael H. K.; Fang, Lei; Chen, Wenhao; Li, Jinguang; Sun, Yuexia

    2011-08-01

    Air cleaning techniques have been applied worldwide with the goal of improving indoor air quality. The effectiveness of applying these techniques varies widely, and pollutant removal efficiency is usually determined in controlled laboratory environments which may not be realized in practice. Some air cleaners are largely ineffective, and some produce harmful by-products. To summarize what is known regarding the effectiveness of fan-driven air cleaning technologies, a state-of-the-art review of the scientific literature was undertaken by a multidisciplinary panel of experts from Europe, North America, and Asia with expertise in air cleaning, aerosol science, medicine, chemistry and ventilation. The effects on health were not examined. Over 26,000 articles were identified in major literature databases; 400 were selected as being relevant based on their titles and abstracts by the first two authors, who further reduced the number of articles to 160 based on the full texts. These articles were reviewed by the panel using predefined inclusion criteria during their first meeting. Additions were also made by the panel. Of these, 133 articles were finally selected for detailed review. Each article was assessed independently by two members of the panel and then judged by the entire panel during a consensus meeting. During this process 59 articles were deemed conclusive and their results were used for final reporting at their second meeting. The conclusions are that: (1) None of the reviewed technologies was able to effectively remove all indoor pollutants and many were found to generate undesirable by-products during operation. (2) Particle filtration and sorption of gaseous pollutants were among the most effective air cleaning technologies, but there is insufficient information regarding long-term performance and proper maintenance. (3) The existing data make it difficult to extract information such as Clean Air Delivery Rate (CADR), which represents a common benchmark for

  3. Self-scrubbing coal{sup TM}: An integrated approach to clean air. A proposed Clean Coal Technology Demonstration Project

    SciTech Connect

    Not Available

    1994-01-01

    This environmental assessment (EA) was prepared by the U.S.Department of Energy (DOE), with compliance with the National Environmental Policy Act (NEPA) of 1969, Council on Environmental Quality (CE) regulations for implementating NEPA (40 CFR 1500-1508) and DOE regulations for compliance with NEPA (10 CFR 1021), to evaluate the potential environmental impacts associated with a proposed demonstration project to be cost-shared by DOE and Custom Coals International (CCI) under the Clean Coal Technology (CCT) Demonstration Program of DOE`s Office of Fossil Energy. CCI is a Pennsylvania general partnership located in Pittsburgh, PA engaged in the commercialization of advanced coal cleaning technologies. The proposed federal action is for DOE to provide, through a cooperative agreement with CCI, cost-shared funding support for the land acquisition, design, construction and demonstration of an advanced coal cleaning technology project, {open_quotes}Self-Scrubbing Coal: An Integrated Approach to Clean Air.{close_quotes} The proposed demonstration project would take place on the site of the presently inactive Laurel Coal Preparation Plant in Shade Township, Somerset County, PA. A newly constructed, advanced design, coal preparation plant would replace the existing facility. The cleaned coal produced from this new facility would be fired in full-scale test burns at coal-fired electric utilities in Indiana, Ohio and PA as part of this project.

  4. Improving the Balance between Jobs and Clean Air.

    ERIC Educational Resources Information Center

    Jasinowski, Jerry J.

    1983-01-01

    The effects of the efforts to improve America's air quality can be measured from two perspectives. One considers changes in air quality; the other, the impact of this undertaking on economic growth, jobs, and productivity. (RM)

  5. 40 CFR 63.5734 - What standards must I meet for resin and gel coat application equipment cleaning operations?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-containing solvents used for removing cured resin or gel coat are exempt from the requirements of 40 CFR part... 40 Protection of Environment 12 2011-07-01 2009-07-01 true What standards must I meet for resin... Pollutants for Boat Manufacturing Standards for Resin and Gel Coat Application Equipment Cleaning...

  6. 40 CFR 63.1298 - Standards for slabstock flexible polyurethane foam production-HAP emissions from equipment cleaning.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Standards for slabstock flexible polyurethane foam production-HAP emissions from equipment cleaning. 63.1298 Section 63.1298 Protection of... Pollutants for Flexible Polyurethane Foam Production § 63.1298 Standards for slabstock flexible...

  7. 40 CFR 63.1298 - Standards for slabstock flexible polyurethane foam production-HAP emissions from equipment cleaning.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 12 2012-07-01 2011-07-01 true Standards for slabstock flexible polyurethane foam production-HAP emissions from equipment cleaning. 63.1298 Section 63.1298 Protection of... Pollutants for Flexible Polyurethane Foam Production § 63.1298 Standards for slabstock flexible...

  8. 40 CFR 63.1298 - Standards for slabstock flexible polyurethane foam production-HAP emissions from equipment cleaning.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Standards for slabstock flexible polyurethane foam production-HAP emissions from equipment cleaning. 63.1298 Section 63.1298 Protection of... Pollutants for Flexible Polyurethane Foam Production § 63.1298 Standards for slabstock flexible...

  9. 40 CFR 63.5734 - What standards must I meet for resin and gel coat application equipment cleaning operations?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-containing solvents used for removing cured resin or gel coat are exempt from the requirements of 40 CFR part... 40 Protection of Environment 12 2010-07-01 2010-07-01 true What standards must I meet for resin... Pollutants for Boat Manufacturing Standards for Resin and Gel Coat Application Equipment Cleaning...

  10. Self-Scrubbing Coal -- an integrated approach to clean air

    SciTech Connect

    Harrison, K.E.

    1997-12-31

    Carefree Coal is coal cleaned in a proprietary dense-media cyclone circuit, using ultrafine magnetite slurries, to remove noncombustible material, including up to 90% of the pyritic sulfur. Deep cleaning alone, however, cannot produce a compliance fuel from coals with high organic sulfur contents. In these cases, Self-Scrubbing Coal will be produced. Self-Scrubbing Coal is produced in the same manner as Carefree Coal except that the finest fraction of product from the cleaning circuit is mixed with limestone-based additives and briquetted. The reduced ash content of the deeply-cleaned coal will permit the addition of relatively large amounts of sorbent without exceeding boiler ash specifications or overloading electrostatic precipitators. This additive reacts with sulfur dioxide (SO{sub 2}) during combustion of the coal to remove most of the remaining sulfur. Overall, sulfur reductions in the range of 80--90% are achieved. After nearly 5 years of research and development of a proprietary coal cleaning technology coupled with pilot-scale validation studies of this technology and pilot-scale combustion testing of Self-Scrubbing Coal, Custom Coals Corporation organized a team of experts to prepare a proposal in response to DOE`s Round IV Program Opportunity Notice for its Clean Coal Technology Program under Public Law 101-121 and Public Law 101-512. The main objective of the demonstration project is the production of a coal fuel that will result in up to 90% reduction in sulfur emissions from coal-fired boilers at a cost competitive advantage over other technologies designed to accomplish the same sulfur emissions and over naturally occurring low sulfur coals.

  11. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard...

  12. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard...

  13. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a)...

  14. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard...

  15. 77 FR 59186 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-26

    ..., 2011, and submitted by the Environmental Integrity Project and the Southern Alliance for Clean Energy... AGENCY Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for...: Pursuant to Clean Air Act (CAA) Section 505(b)(2), the EPA Administrator signed an Order, dated August...

  16. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a)...

  17. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard...

  18. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard...

  19. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a)...

  20. No Need to Wait for the Clean Air Dividend

    NASA Technical Reports Server (NTRS)

    Shindell, Drew

    2012-01-01

    upfront costs of some measures can be prohibitive even when they eventually pay for themselves. But this can be overcome by mechanisms such as international financing of capital costs. For other measures, the costs are typically borne by a few while the benefits accrue to everybody. In such cases civil society and governments must get involved. Governments are starting to act. In February, the US, Canada, Sweden, Bangladesh, Ghana and Mexico launched the Climate and Clean Air Coalition to support implementation of measures like these. This coalition will hopefully expand and achieve rapid, widespread adoption of measures to cut black carbon and ozone. While the climate benefits will be substantial, it is important to note that these measures cannot substitute for cuts in carbon dioxide. Black carbon, ozone, carbon monoxide and methane stay in the atmosphere for a fairly short time - a few days for black carbon and about a decade for methane. They thus respond quickly to emissions changes and give us substantial leverage over near-term climate change. In contrast, carbon dioxide is very long-lived and so responds slowly to emissions changes. This means that cuts have little immediate impact, but it also means they must be made now to avoid disastrous changes later on. Controlling short-lived climate pollutants is thus an issue of fairness. Much as failure to reduce carbon dioxide emissions soon would condemn future generations to disastrous change, failure to reduce near-term climate change condemns those alive today to suffer worsening effects of the sort already seen. Some wonder if we really can do both. We can, and we must.

  1. 76 FR 21345 - Science Advisory Board Staff Office; Notification of Two Public Teleconferences of the Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-15

    ... Scientific Advisory Committee (CASAC) Air Monitoring and Methods Subcommittee AGENCY: Environmental... ] Advisory Board (SAB) Staff Office announces two public teleconference calls of the Clean Air Scientific Advisory Committee (CASAC) Air Monitoring and Methods Subcommittee (AMMS) to provide advice on EPA's...

  2. 75 FR 54146 - Science Advisory Board Staff Office; Notification of a Public Meeting of the Clean Air Scientific...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-03

    ... Scientific Advisory Committee (CASAC) Ambient Air Monitoring & Methods Subcommittee (AAMMS) to provide advice... AGENCY Science Advisory Board Staff Office; Notification of a Public Meeting of the Clean Air Scientific Advisory Committee (CASAC), Ambient Air Methods and Monitoring Subcommittee (AAMMS) AGENCY:...

  3. Smogbusters: Grassroots Action for Clean Air and Sustainable Transport in Australia

    ERIC Educational Resources Information Center

    Manners, Eric; Wake, David; Carlisle, Rachel

    2009-01-01

    Smogbusters was a national, community-based, government-funded community education program promoting clean air and sustainable transport in Australia from 1994 to 2002. Smogbusters aimed to improve air quality primarily by raising awareness about motor vehicle transport and its negative impacts on health, the environment and communities, and by…

  4. 76 FR 76762 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-08

    ... Clean Air Act (``CAA''), 42 U.S.C. 7413(b) and 7477. Defendant produces nitric acid, which is used in the production of ammonium nitrate and other fertilizers and explosives. The nitric acid process results in the emissions of regulated air pollutants, including nitrogen oxides (``NO X ''). The...

  5. Impact of Clean Air Regulations on Nitrogen Fate and Transport in Neuse River Basin

    EPA Science Inventory

    We investigated impacts of Clean Air Act (CAA) nitrogen emissions regulations on the fate and transport of nitrogen for two watersheds in the Neuse River Basin. The Soil and Water Assessment Tool (SWAT) and the Community Multi-Scale Air Quality (CMAQ) models were used. Two scenar...

  6. 75 FR 54871 - Science Advisory Board Staff Office; Notification of a Clean Air Scientific Advisory Committee...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-09

    ... Quality Standards for NO X and SO X : First External Review Draft (March 2010) (75 FR 10479- 10481). CASAC... Office announces a public meeting of the Clean Air Scientific Advisory Committee NO X and SO X Secondary... Assessment for the Review of the Secondary National Ambient Air Quality Standards for NO X and SO X :...

  7. 75 FR 51483 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-20

    ...' violations of the Clean Air Act, 42 U.S.C. 7411 et seq., and the New Jersey Air Pollution Control Act, N.J.S... to the Consent Decree. Comments should be addressed to the Assistant Attorney General, Environment... at the stated address. Maureen Katz, Assistant Chief, Environmental Enforcement Section,...

  8. 10 CFR 429.43 - Commercial heating, ventilating, air conditioning (HVAC) equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Commercial heating, ventilating, air conditioning (HVAC... Commercial heating, ventilating, air conditioning (HVAC) equipment. Link to an amendment published at 78 FR... § 429.11 are applicable to commercial HVAC equipment; and (2) For each basic model of commercial...

  9. 24 CFR 3280.813 - Outdoor outlets, fixtures, air-conditioning equipment, etc.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Outdoor outlets, fixtures, air... Electrical Systems § 3280.813 Outdoor outlets, fixtures, air-conditioning equipment, etc. (a) Outdoor fixtures and equipment shall be listed for use in wet locations, except that if located on the underside...

  10. 24 CFR 3280.813 - Outdoor outlets, fixtures, air-conditioning equipment, etc.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Outdoor outlets, fixtures, air... Electrical Systems § 3280.813 Outdoor outlets, fixtures, air-conditioning equipment, etc. Link to an amendment published at 78 FR 73992, Dec. 9, 2013. (a) Outdoor fixtures and equipment shall be listed for...

  11. 24 CFR 3280.813 - Outdoor outlets, fixtures, air-conditioning equipment, etc.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Outdoor outlets, fixtures, air... Electrical Systems § 3280.813 Outdoor outlets, fixtures, air-conditioning equipment, etc. (a) Outdoor fixtures and equipment shall be listed for use in wet locations, except that if located on the underside...

  12. 24 CFR 3280.813 - Outdoor outlets, fixtures, air-conditioning equipment, etc.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Outdoor outlets, fixtures, air... Electrical Systems § 3280.813 Outdoor outlets, fixtures, air-conditioning equipment, etc. (a) Outdoor fixtures and equipment shall be listed for use in wet locations, except that if located on the underside...

  13. 24 CFR 3280.813 - Outdoor outlets, fixtures, air-conditioning equipment, etc.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Outdoor outlets, fixtures, air... Electrical Systems § 3280.813 Outdoor outlets, fixtures, air-conditioning equipment, etc. (a) Outdoor fixtures and equipment shall be listed for use in wet locations, except that if located on the underside...

  14. 40 CFR 261.35 - Deletion of certain hazardous waste codes following equipment cleaning and replacement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... required to be cleaned or replaced under 40 CFR 261.35 was cleaned or replaced as represented in the... limited to, treatment cylinders, sumps, tanks, piping systems, drip pads, fork lifts, and trams, in...

  15. 40 CFR 261.35 - Deletion of certain hazardous waste codes following equipment cleaning and replacement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... required to be cleaned or replaced under 40 CFR 261.35 was cleaned or replaced as represented in the... drippage, or hazardous waste decomposition products to the ground water, surface water, or atmosphere....

  16. 40 CFR 261.35 - Deletion of certain hazardous waste codes following equipment cleaning and replacement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... required to be cleaned or replaced under 40 CFR 261.35 was cleaned or replaced as represented in the... drippage, or hazardous waste decomposition products to the ground water, surface water, or atmosphere....

  17. Your Right to Clean Air, A Manual for Citizen Action.

    ERIC Educational Resources Information Center

    1970

    This manual provides the citizen with basic information for taking action against air pollution. A summary of the effects of various concentrations of sulfur oxides, particulate matter, carbon monoxide, photochemical smog, and hydrocarbons is presented. Suggestions are made for obtaining information about community air pollution problems, and how…

  18. Effect of cleaning procedure and hygienic condition of milking equipment on bacterial count of bulk tank milk.

    PubMed

    Bava, Luciana; Zucali, Maddalena; Sandrucci, Anna; Brasca, Milena; Vanoni, Laura; Zanini, Lucio; Tamburini, Alberto

    2011-05-01

    The aim of the study was to describe the characteristics of cleaning procedures for milking equipment applied in intensive dairy farms in Lombardy (Italy) and to study their relationships with bacterial count of bulk milk and hygienic condition of milking machine components. A group of 22 dairy farms was visited twice (winter and summer) in order to collect bulk tank milk and post-rinse water samples and swabs from liners and milk receiver. Samples were analysed to determine: standard plate count (SPC), laboratory pasteurization count (LPC), psychrotrophic bacteria count (PBC), coliform count (CC) and Escherichia coli. Cleaning procedures were monitored using electronic milk flow meters with specific software for the measurement of the duration of each cleaning phase, circulating solution temperature and electrical conductivity, turbulence and water filling percentage of pipelines. The results showed that farms classified as high and low milk total bacteria count significantly differed both in terms of liners and receiver bacterial contamination and in terms of water temperature reached during the detergent phase of cleaning milking equipment. Significant positive correlations were found among total bacteria count in milk and bacterial contamination of the liners. Maximum water temperature reached during the cleaning cycle of milking equipment was very low (34.4±8.9°C on average); most of the observations (88.6%) corresponded to water temperatures <45°C. Cleaning temperature was related to psychrotrophic bacteria count of milk and post-rinse water and coliform count in liners. Routine check and regulation of water temperature during the washing phase of the milking machine can be a simple and effective way to control one of the main risk factors for bacteriological quality of bulk tank milk. PMID:21371358

  19. Effect of cleaning procedure and hygienic condition of milking equipment on bacterial count of bulk tank milk.

    PubMed

    Bava, Luciana; Zucali, Maddalena; Sandrucci, Anna; Brasca, Milena; Vanoni, Laura; Zanini, Lucio; Tamburini, Alberto

    2011-05-01

    The aim of the study was to describe the characteristics of cleaning procedures for milking equipment applied in intensive dairy farms in Lombardy (Italy) and to study their relationships with bacterial count of bulk milk and hygienic condition of milking machine components. A group of 22 dairy farms was visited twice (winter and summer) in order to collect bulk tank milk and post-rinse water samples and swabs from liners and milk receiver. Samples were analysed to determine: standard plate count (SPC), laboratory pasteurization count (LPC), psychrotrophic bacteria count (PBC), coliform count (CC) and Escherichia coli. Cleaning procedures were monitored using electronic milk flow meters with specific software for the measurement of the duration of each cleaning phase, circulating solution temperature and electrical conductivity, turbulence and water filling percentage of pipelines. The results showed that farms classified as high and low milk total bacteria count significantly differed both in terms of liners and receiver bacterial contamination and in terms of water temperature reached during the detergent phase of cleaning milking equipment. Significant positive correlations were found among total bacteria count in milk and bacterial contamination of the liners. Maximum water temperature reached during the cleaning cycle of milking equipment was very low (34.4±8.9°C on average); most of the observations (88.6%) corresponded to water temperatures <45°C. Cleaning temperature was related to psychrotrophic bacteria count of milk and post-rinse water and coliform count in liners. Routine check and regulation of water temperature during the washing phase of the milking machine can be a simple and effective way to control one of the main risk factors for bacteriological quality of bulk tank milk.

  20. 75 FR 63471 - Science Advisory Board Staff Office; Notification of a Public Teleconference of the Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-15

    ... in 75 FR 54146-54147, the Ambient Air Methods and Monitoring Subcommittee (AAMMS) of the Clean Air... Scientific Advisory Committee (CASAC) AGENCY: Environmental Protection Agency (EPA). ACTION: Notice. SUMMARY... teleconference of the Clean Air Scientific Advisory Committee (CASAC) to conduct a quality review and approve...

  1. 76 FR 21346 - Science Advisory Board Staff Office, Notification of a Public Teleconference of the Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-15

    ... AGENCY Science Advisory Board Staff Office, Notification of a Public Teleconference of the Clean Air... the Clean Air Scientific Advisory Committee (CASAC) Lead Review Panel to provide consultative advice on EPA's draft Integrated Review Plan for the National Ambient Air Quality Standards for Lead...

  2. 76 FR 53452 - Clean Air Act Operating Permit Program; Response to Petition To Reopen the 2001 Title V Permit...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... AGENCY Clean Air Act Operating Permit Program; Response to Petition To Reopen the 2001 Title V Permit for.... ] SUMMARY: Pursuant to the Clean Air Act (CAA), the Director of the EPA Region III Air Protection Division... Reliant Energy Mid-Atlantic Power Holdings, LLC, for its Portland Generating Station in Northampton...

  3. The regulation of hazardous air pollutants under the Clean Air Act Amendments of 1990: Effects on the Portland cement industry

    SciTech Connect

    Mikols, E.H.; Dougherty, A.

    1996-07-01

    Title III of the 1990 Clean Air Act Amendments (CAAA) addresses the control of hazardous air pollutants (HAPs) from major sources of air pollution in the US. In the CAAA, Congress defined 189 compounds as hazardous air pollutants in need of additional control by the Environmental Protection Agency (EPA). Congress directed EPA to identify the major source categories which emit HAPs and to prepare regulations that would reduce and control future HAP emissions. This paper outlines the activities undertaken by EPA to regulate HAP emissions from Portland cement plants and the program developed by the Portland cement manufacturing industry to cope with Title III.

  4. Wet-air oxidation cleans up black wastewater

    SciTech Connect

    Not Available

    1993-09-01

    Sterling Organics produces the analgesic paracetamol (acetaminophen) at its Dudley, England, plant. The wastewater from the batch process contains intermediates such as para-aminophenol (PAP) and byproducts such as thiosulfates, sulfites and sulfides. To stay ahead of increasingly strict environmental legislation, Sterling Organics installed a wet-air oxidation system at the Dudley facility in August 1992. The system is made by Zimpro Environmental Inc. (Rothschild, Wis.). Zimpro's wet-air oxidation system finds a way around the limitations of purely chemical or physical processes. In the process, compressed air at elevated temperature and pressure oxidizes the process intermediates and byproducts and removes the color from the wastewater.

  5. Plants + soil/wetland microbes: Food crop systems that also clean air and water

    NASA Astrophysics Data System (ADS)

    Nelson, Mark; Wolverton, B. C.

    2011-02-01

    The limitations that will govern bioregenerative life support applications in space, especially volume and weight, make multi-purpose systems advantageous. This paper outlines two systems which utilize plants and associated microbial communities of root or growth medium to both produce food crops and clean air and water. Underlying these approaches are the large numbers and metabolic diversity of microbes associated with roots and found in either soil or other suitable growth media. Biogeochemical cycles have microbial links and the ability of microbes to metabolize virtually all trace gases, whether of technogenic or biogenic origin, has long been established. Wetland plants and the rootzone microbes of wetland soils/media also been extensively researched for their ability to purify wastewaters of a great number of potential water pollutants, from nutrients like N and P, to heavy metals and a range of complex industrial pollutants. There is a growing body of research on the ability of higher plants to purify air and water. Associated benefits of these approaches is that by utilizing natural ecological processes, the cleansing of air and water can be done with little or no energy inputs. Soil and rootzone microorganisms respond to changing pollutant types by an increase of the types of organisms with the capacity to use these compounds. Thus living systems have an adaptive capacity as long as the starting populations are sufficiently diverse. Tightly sealed environments, from office buildings to spacecraft, can have hundreds or even thousands of potential air pollutants, depending on the materials and equipment enclosed. Human waste products carry a plethora of microbes which are readily used in the process of converting its organic load to forms that can be utilized by green plants. Having endogenous means of responding to changing air and water quality conditions represents safety factors as these systems operate without the need for human intervention. We review

  6. Breathless in Los Angeles: The Exhausting Search for Clean Air

    PubMed Central

    Künzli, Nino; McConnell, Rob; Bates, David; Bastain, Tracy; Hricko, Andrea; Lurmann, Fred; Avol, Ed; Gilliland, Frank; Peters, John

    2003-01-01

    Population growth and the proliferation of roadways in Southern California have facilitated a glut of mobile air pollution sources (cars and trucks), resulting in substantial atmospheric pollution. Despite successful efforts over the past 40 years to reduce pollution, an alarming set of health effects attributable to air pollution have been described in Southern California. The Children’s Health Study indicates that reduced lung function growth, increased school absences, asthma exacerbation, and new-onset asthma are occurring at current levels of air pollution, with sizable economic consequences. We describe these findings and urge a more aggressive effort to reduce air pollution exposures to protect our children’s health. Lessons from this “case study” have national implications. PMID:12948969

  7. Eastern States Harness Clean Energy to Promote Air Quality

    SciTech Connect

    Not Available

    2007-10-01

    States on the East Coast are including renewable energy and energy efficiency projects into their air quality plans that they submit to the EPA to address nonattainment for nitrogen oxides and other pollutants.

  8. The Clean Air and Clean Water Acts: The "Fifth" and "Eighth" Most Significant Events.

    ERIC Educational Resources Information Center

    Knight, Laurel A.

    1991-01-01

    The history and impact of this federal legislation are discussed. An assessment of the progress of federal legislation in these areas is presented. Key issues for federal legislation regarding water and air quality are identified. (CW)

  9. 76 FR 30545 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-26

    ...Pursuant to section 112(l) of the Clean Air Act (``CAA'') and Federal regulations promulgated thereunder, the Maine Department of Environmental Protection (``ME DEP'') submitted a request for approval to implement and enforce the amended ``Chapter 125: Perchloroethylene Dry Cleaner Regulation'' (Maine Dry Cleaner Rule) as a partial substitution for the amended National Emissions Standards for......

  10. Stability of air toxic gases listed in Title III Clean Air Act Amendments

    SciTech Connect

    Jayanty, R.K.M.; Jaffe, L.B.; Albritton, J.R.; Jackson, M.D.; Midgett, M.R.

    1992-01-01

    A repository of 59 organic compounds has been established by the U.S. Environmental Protection Agency (EPA) for use as gas standards in performance audits during field validation of emission concentrations from stationary sources. These compounds are listed in Title III of the 1990 Clean Air Act Amendment. The compounds are prepared in compressed gas cylinders and recyclable aluminum containers. Three concentration ranges were selected: low (20 to 200 ppb), mid-level (0.5 to 5 ppm), and high (5 to 50 ppm). The recyclable aluminum containers were only prepared in the low range, and pressures were generally below 400 psig. The compressed gas cylinders contained pressures up to 2000 psig. In this program to ensure that the concentration of each gas standard had not changed, each standard was analyzed periodically for stability. The gas mixtures were analyzed by the manufacturer before shipment. They were then analyzed upon receipt, and reanalyzed periodically to determine any change in concentration. The stability data obtained to date indicates that many compounds are stable in the compressed gas cylinders; however, some of the compounds in the recyclable containers are not stable.

  11. 40 CFR 86.1832-01 - Optional equipment and air conditioning for test vehicles.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Optional equipment and air conditioning for test vehicles. For test vehicles selected under §§ 86.1822-01... be expected to influence emissions include, but are not limited to: air conditioning, power steering...) Except for air conditioning, where it is expected that 33 percent or less of a car line, within a...

  12. Twenty-third DOE/NRC Nuclear Air Cleaning and Treatment Conference

    SciTech Connect

    Bellamy, R.R.; Hayes, J.J.; First, M.W.

    1995-03-24

    This paper presents the details of the Nuclear Air Cleaning and Treatment Conference held in Buffalo, New York during July 1994. Topics discussed include: nuclear air cleaning codes and standards; waste disposal; particulate filter developments; sampling and monitoring of process and effluent streams; off-gasses from fuel reprocessing; adsorbents and adsorption; accident control and analysis; revised source terms for power plant accidents; and the highlight of the conference concerned operations at the West Valley DOE facility where construction is underway to solidify radioactive wastes.

  13. The effect of the clean air act of Erie County, New York on restaurant employment.

    PubMed

    Hyland, A; Vena, C; Cummings, K M; Lubin, A

    2000-11-01

    The objective of this study was to assess the economic impact of the Erie County, New York, Clean Air Act on the restaurant industry by examining restaurant employment and payroll statistics. Monthly county-specific data were compared between 1996 (before the law), 1997 (after phase 1, which required 80% of indoor restaurant seating to be smoke-free), and 1998 (after phase 2 which prohibited smoking in 100% of indoor restaurant seating). Erie County's Clean Air Act had no adverse economic impact on its restaurant industry. PMID:18019963

  14. CAN SORBENT-BASED GAS PHASE AIR CLEANING FOR VOCS SUBSTITUTE FOR VENTILATION IN COMMERCIAL BUILDINGS?

    SciTech Connect

    Fisk, William; Fisk, William J.

    2007-08-01

    This paper reviews current knowledge about the suitability of sorbent-based air cleaning for removing volatile organic compounds (VOCs) from the air in commercial buildings, as needed to enable reductions in ventilation rates and associated energy savings. The principles of sorbent air cleaning are introduced, criteria are suggested for sorbent systems that can counteract indoor VOC concentration increases from reduced ventilation, major findings from research on sorbent performance for this application are summarized, and related priority research needs are identified. Major conclusions include: sorbent systems can remove a broad range of VOCs with moderate to high efficiency, sorbent technologies perform effectively when challenged with VOCs at the low concentrations present indoors, and there is a large uncertainty about the lifetime and associated costs of sorbent air cleaning systems when used in commercial buildings for indoor VOC control. Suggested priority research includes: experiments to determine sorbent system VOC removal efficiencies and lifetimes considering the broad range and low concentration of VOCs indoors; evaluations of in-situ regeneration of sorbents; and an updated analysis of the cost of sorbent air cleaning relative to the cost of ventilation.

  15. Sorbent-Based Gas Phase Air Cleaning for VOCs in CommercialBuildings

    SciTech Connect

    Fisk, William J.

    2006-05-01

    This paper provides a review of current knowledge about the suitability of sorbent-based air cleaning for removing volatile organic compounds (VOCs) from the air in commercial buildings as needed to enable reductions in ventilation rates and associated energy savings. The fundamental principles of sorbent air cleaning are introduced, criteria are suggested for sorbent systems that can counteract indoor VOC concentration increases from reduced ventilation, major findings from research on sorbent performance for this application are summarized, novel sorbent technologies are described, and related priority research needs are identified. Major conclusions include: sorbent systems can remove a broad range of VOCs with moderate to high efficiency, sorbent technologies perform effectively when challenged with VOCs at the low concentrations present indoors, and there is a large uncertainty about the lifetime and associated costs of sorbent air cleaning systems when used in commercial buildings for indoor VOC control. Suggested priority research includes: experiments to determine sorbent system VOC removal efficiencies and lifetimes considering the broad range and low concentration of VOCs indoors; evaluations of in-situ regeneration of sorbents; and an updated analysis of the cost of sorbent air cleaning relative to the cost of ventilation.

  16. 40 CFR 49.5 - Tribal requests for additional Clean Air Act provisions for which it is not appropriate to treat...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Tribal requests for additional Clean... TRIBAL CLEAN AIR ACT AUTHORITY Tribal Authority § 49.5 Tribal requests for additional Clean Air Act... request that the Administrator specify additional provisions of the Clean Air Act for which it would...

  17. 78 FR 1251 - Notice of Lodging of Proposed Consent Decree Under the Clean Air Act, the Clean Water Act and the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-08

    ... Water Act, 33 U.S.C. 1301 et seq.; and the Resource Conservation and Recovery Act, 42 U.S.C. 6901 et seq... of Lodging of Proposed Consent Decree Under the Clean Air Act, the Clean Water Act and the Resource Conservation and Recovery Act On December 31, 2012, the Department of Justice lodged a proposed Consent...

  18. 40 CFR 261.35 - Deletion of certain hazardous waste codes following equipment cleaning and replacement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... drippage, or hazardous waste decomposition products to the ground water, surface water, or atmosphere. (1... appropriate solvent until dioxins and dibenzofurans are not detected in the final solvent rinse. (iii... required to be cleaned or replaced under 40 CFR 261.35 was cleaned or replaced as represented in...

  19. Biodiesel Clears the Air in Underground Mines, Clean Cities, Fact Sheet, June 2009

    SciTech Connect

    Not Available

    2009-06-01

    Mining companies are using biodiesel in their equipment to help clear the air of diesel particulate matter (DPM). This action improves air quality and protects miners' lungs. Though using biodiesel has some challenges in cold weather, tax incentives, and health benefits make it a viable option.

  20. Window-mounted unit cleans air at hazardous waste site

    SciTech Connect

    Battaglia, J.M. ); Sawyer, P.

    1994-07-01

    Uncontrolled hazardous waste sites present the potential for exposure to numerous airborne chemicals--both identified and unidentified. This was the case at an Elizabeth, N.J., remediation project managed by a major environmental contractor. The four-acre site housed three active manufacturing facilities and was bordered by an operation commuter railroad line. About 6,300 drums of assorted organic chemicals, mostly acid chlorides and bromides, awaited sampling and removal. In addition, 120 tanks and vessels required sampling, characterization and removal. Due to site restrictions, support trailers were located relatively close to active work areas. Damaged drums littering the site contained water-reactive, organic acid chlorides and bromides, and released slight emissions during humid or rainy conditions. Shifting winds could (and did) carry trace releases or trace contaminants toward the trailers, potentially exposing unprotected workers. Efforts were begun to alleviate even trace contaminant at levels in the remediation site's temporary office trailers. One potential solution to managing trace contaminants at the site was to use a window-mounted, air conditioner-type unit that would replenish each trailer with filtered air three times an hour, and provide positive pressure in the trailer to compensate for repeated openings and closings of doors. The design uses common, off-the-shelf components to temper the approximately 10 percent makeup air, which provides positive pressure.

  1. Subterranean heat exchanger for refrigeration air conditioning equipment

    SciTech Connect

    Rothwell, H.

    1980-09-30

    Heat exchanger apparatus for use with refrigeration cycle heating and cooling equipment is disclosed. In the preferred embodiment, it cooperates with and modifies refrigeration equipment including a compressor, an expansion valve, an evaporator coil and a closed loop for cycling refrigerant. This apparatus is a sealed container adapted to be placed in a well extending into artesian (Relatively heated or chilled) formations whereby the water of the formation stabilizes the temperature around the unit and enables heating and cooling. The sealed unit receives refrigerant from the top which flows along the sidewall at a reduced temperature, thereby condensing on the sidewall and trickling down the sidewall to collect in a sump at the bottom where the compressor pump picks up condensed refrigerant as a liquid and pumps it out of the artesian well to the connected refrigeration equipment.

  2. Cleaning contaminated soil using electrical heating and air stripping

    SciTech Connect

    Buettner, H.M.; Daily, W.D.

    1995-08-01

    In the summer of 1992, a proof-of-concept demonstration of direct electrical heating and air stripping was conducted for enhancing the removal of a volatile organic contaminant, trichloroethylene (TCSE), from soil. Six electrodes were buried in shallow boreholes so that a target region 6.1 m in diameter and 3.05 m in height was heated by ohmic dissipation of power-line-frequency electrical currents supplied by a diesel generator. Air stripping of TCE contamination from the same region was accomplished from a single well at the center of the heated volume. The electrical energy used during the demonstration was 3.46 {times} 10{sup 10} J (9,600 kW {center_dot} h), and the temperature of the extracted air rose from 16 C to 38 C. An energy balance shows that input energy is consistent with the temperature rise in the target volume and the amount of water vaporized at the electrodes. Prior to heating, the TCE concentration in the vapor decreased from about 80 parts per million by volume (ppm{sub v}) to around 60 ppm{sub v}. As soon as electrical heating started, TCE concentrations began to increase. Some concentration data were lost shortly after electrical heating began. After the system was repaired, the TCE concentration fell rapidly from about 140 ppm{sub v} to 5 ppm{sub v} over a period of about 25 days. A simple two-dimensional model for calculation of heating rates is also presented and verified experimentally. Finally some of the operation and safety issues associated with electrical heating are discussed.

  3. 77 FR 15125 - Notice of Lodging of Second Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-14

    ... of Lodging of Second Consent Decree Under the Clean Air Act Notice is hereby given that on March 6, 2012, a proposed Second Consent Decree in United States and the State of Kansas v. Coffeyville... matter at its oil refinery located in Coffeyville, Kansas. Under the proposed Second Consent Decree...

  4. 77 FR 61641 - Notice Lodging of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-10

    ... Rico in the lawsuit entitled United States v. Suiza Dairy Corporation, Civil Action No. 3:12-cv-01810... Dairy Corporation, to resolve alleged violations of Section 112(r) of the Clean Air Act at dairies in... the two dairies; (2) perform supplemental environmental projects (``SEPs'') that will...

  5. 76 FR 52692 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-23

    ... on August 17, 2011, a Consent Decree in United States of America v. Erie Coke Corporation, Civil... Pennsylvania. In this action, the United States sought injunctive relief and penalties against Erie Coke Corporation (``Erie Coke'') pursuant to Section 113(b) of the Clean Air Act, 42 U.S.C. 7413(b), for...

  6. 76 FR 64010 - Special Rules Governing Certain Information Obtained Under the Clean Air Act: Technical Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-17

    ... to Special Rules Governing Certain Information Obtained Under the Clean Air Act (76 FR 30782). In... section 307(d). (See 76 FR 30782: ``The Administrator determined that this action is subject to the... for the data. (See 76 FR 30782, 30784, 30815 (May 26, 2011); see also 75 FR 39094, 39098,...

  7. Assessing the Link between Environmental Concerns and Consumers' Decisions to Use Clean-Air Vehicles

    ERIC Educational Resources Information Center

    Plax, Timothy G.; Kearney, Patricia; Ross, Ted J.; Jolly, J. Christopher

    2008-01-01

    A consulting contract with the California Air Resources Board led to a project examining how California drivers' and fleet managers' perceptions, attitudes, and consumer behavior regarding Clean Vehicle Technologies influenced their own energy choices when it came to purchasing vehicles. The consultants examined archival research, conducted focus…

  8. 78 FR 27234 - Notification of a Public Teleconference of the Clean Air Scientific Advisory Committee (CASAC...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-09

    ... solicited nominations for the CASAC NO X Primary NAAQS Review Panel on October 17, 2012 (77 FR 63827-63828...); Oxides of Nitrogen Primary NAAQS Review Panel AGENCY: Environmental Protection Agency (EPA). ACTION... the Clean Air Scientific Advisory Committee (CASAC) Oxides of Nitrogen (NO X ) Primary...

  9. 75 FR 27580 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-17

    ... proposed Consent Decree (``Decree'') in United States v. The Pep Boys--Manny, Moe & Jack, and Baja, Inc.... EPA''), sought penalties and injunctive relief under the Clean Air Act (``CAA'') against The Pep Boys... of Justice, Washington, DC 20044-7611, and should refer to United States v. The Pep Boys--Manny,...

  10. 76 FR 45618 - Notice of Lodging of Joint Stipulation Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ... of Lodging of Joint Stipulation Under the Clean Air Act Notice is hereby given that on July 25, 2011, a proposed Joint Stipulation to Modify the Sixth Amendment to the Consent Decree entered in United States v. BP Exploration and Oil Co., et al., (Civil No. 2:96 CV 095 RL) (``Joint Stipulation''),...

  11. Impact of Clean Air Act Regulations on Nitrogen Fate and Transport in Neuse River Basin

    EPA Science Inventory

    This study investigated impacts of Clean Air Act Amendment (CAAA) NOx emissions regulations on the fate and transport of nitrogen for two watersheds in the Neuse River Basin, North Carolina, USA from 1990 to 2020. The Soil and Water Assessment Tool (SWAT) and the Community Multi-...

  12. 77 FR 66462 - Clean Air Act Advisory Committee; Notice of Charter Renewal

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-05

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Clean Air Act Advisory Committee; Notice of Charter Renewal AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of charter renewal. The charter for the U.S. Environmental Protection...

  13. 75 FR 22548 - Requirements for Control Technology Determinations for Major Sources in Accordance With Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-29

    ... March 30, 2010, when EPA published a proposed rule (75 FR 15655) amending the Section 112(j) rule (40... as provided in the SUPPLEMENTARY INFORMATION section of the March 30, 2010 (75 FR 15655) Federal... in Accordance With Clean Air Act Sections, Sections 112(g) and 112(j) AGENCY:...

  14. 76 FR 61738 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-05

    ..., 2011, a proposed Consent Decree in United States and Allegheny County Health Department v. Eastman... County Health Department for violations of the Clean Air Act, 42 U.S.C. 7401 et seq., alleged in a Complaint filed on September 28, 2011. In the Complaint, the United States and the Allegheny County...

  15. 77 FR 28897 - Notice of Lodging of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-16

    ..., 2012, a proposed Consent Decree in United States of America v. American Sugar Refining, Inc., Civil... Consent Decree in this Clean Air Act enforcement action against American Sugar Refining, Inc. (``ASR... environmental violations at ASR's sugar refinery in Baltimore, Maryland. In addition to the payment of a...

  16. 75 FR 62421 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-08

    ... that on September 30, 2010, a proposed Consent Decree in United States of America v. Dakota Ethanol... Dakota Ethanol, LLC pursuant to Sections 111 and 502(a) of the Clean Air Act (the ``Act''), 42 U.S.C... violations of the Act. Dakota Ethanol, LLC owns and operates an ethanol production facility in Lake...

  17. 40 CFR 2.301 - Special rules governing certain information obtained under the Clean Air Act.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROTECTION AGENCY GENERAL PUBLIC INFORMATION Confidentiality of Business Information § 2.301 Special rules governing certain information obtained under the Clean Air Act. (a) Definitions. For the purpose of this... proposed standard or limitation: (A) Information concerning research, or the results of research, on...

  18. 75 FR 74048 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-30

    ... section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), 42 U.S.C. 7413(g), notice is..., 42 U.S.C. 7410(k)(2), to take action on certain State Implementation Plan (``SIP'') submittals by...

  19. 78 FR 1883 - Notice of Lodging of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-09

    ... alleges that Wisconsin Public Service Corporation (``WPS'') failed to comply with certain requirements of... regulations. The complaint alleges that WPS failed to obtain appropriate permits and failed to install and... resolve past Clean Air Act violations and would require WPS to reduce harmful emissions of sulfur...

  20. HAVE U.S. SURFACE WATERS RESPONDED TO THE 1990 CLEAN AIR ACT AMENDMENTS?

    EPA Science Inventory

    Title IV of the 1990 Clean Air Act Amendments (CAAA) set target reductions for sulfur and nitrogen emissions from industrial sources as a means of reducing the acidity in deposition. One of the intended effects of the reductions was to decrease the acidity of low alkalinity wate...

  1. 76 FR 22918 - Notice of Lodging of Consent Decree Pursuant to the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-25

    ..., 2011, a proposed Consent Decree in United States et al. v. Terra Industries Inc. et al., Civ. A. No. 5... and injunctive relief for violations of the Clean Air Act (``CAA'') by Terra Industries Inc. (``Terra Industries''), Terra International (Oklahoma) Inc. (``Terra Oklahoma''), Terra Nitrogen, Limited...

  2. 75 FR 32210 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-07

    ... proposed Consent Decree (``Decree'') in United States v. The Scrap Yard, LLC, d/b/a/ Cleveland Scrap, Civil.... EPA''), sought penalties and injunctive relief under the Clean Air Act (``CAA'') against The Scrap Yard, LLC, d/b/a/Cleveland Scrap (``Defendant'') relating to Defendant's Cleveland, Ohio...

  3. 76 FR 28026 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-13

    ...: Open meeting notice; Pursuant to 5 U.S.C. App. 2 Section 10(a)(2), notice is hereby given that the Clean Air Act Advisory Committee will hold their next open ] meeting on Wednesday June 8, 2011 from 8 a... available on a first come, first served basis. The Economic Incentives and Regulatory...

  4. 75 FR 25855 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-10

    ... Addresses: Open meeting notice; Pursuant to 5 U.S.C. App. 2 Section 10(a)(2), notice is hereby given that the Clean Air Act Advisory Committee will hold its next open meeting on May 27, 2010 from 8 a.m. to 4... available on a first come, first served basis. The Economic Incentives and ] Regulatory...

  5. 75 FR 56530 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-16

    ...: Open meeting notice; Pursuant to 5 U.S.C. App. 2 Section 10(a)(2), notice is hereby given that the Clean Air Act Advisory Committee will hold their next open meeting on Wednesday, October 6, 2010 from 8... and Regulatory Innovations subcommittee will meet on Tuesday, October 5, 2010 from 8:30 a.m. to 12...

  6. [Use of vertical SODAR equipment in monitoring the extent of air pollution].

    PubMed

    Lehmann, H R; Küchler, W

    1989-06-01

    The authors inform about the vertical-SODAR-equipment developed at the Heinrich-Hertz-Institut (HHI) and discuss the possibilities of application especially under the aspect of the air pollution control. PMID:2800627

  7. [Use of vertical SODAR equipment in monitoring the extent of air pollution].

    PubMed

    Lehmann, H R; Küchler, W

    1989-06-01

    The authors inform about the vertical-SODAR-equipment developed at the Heinrich-Hertz-Institut (HHI) and discuss the possibilities of application especially under the aspect of the air pollution control.

  8. Citizen suit Clean Air Act enforcement: An update

    SciTech Connect

    Wright, W.G. Jr.

    1999-07-01

    Almost every federal environmental statute has a provision that allows citizens to sue violators in lieu of governmental enforcement authorities under certain circumstances. Generally, if the relevant governmental enforcement authority was not deemed to be diligently prosecuting enforcement action against an alleged violator and certain procedural requirements were met a citizens suit could be filed in federal court. If a violation was proved penalties could be assessed against the violator and the plaintiff citizen could receive reimbursement of both his or her attorney's fees and other expenses. Historically, however, the only federal statute that has been the subject of significant citizens suit activity has been the federal Clean Water Act (CWA). This paper will explore a variety of events that are expected to significantly increase the number of citizen suits CAA permitted facilities will face over the next ten years. The paper will briefly address the role the Title V operating permit will play. It will also include a discussion of how this permit will now encompass specific emission limitations along with a mandate to report exceedances. Further, and equally important, will be the role of the 1997 federal Environmental Protection Agency any credible evidence rule which potentially broadens the type, amount, and accessibility available to a CAA citizen suit plaintiff. This rule along with the additional monitoring data that will be generated by the Title V periodic and compliance assurance monitoring requirements will be an issue. Two important CAA citizen suits will be discussed which illustrate the potential role of credible evidence. Also, recent citizen suit decisions involving other federal environmental statutes with implications for the CAA will be examined. Further, the paper will provide some thoughts on how facilities can protect themselves to the extent possible against citizen suits.

  9. 76 FR 55799 - Approval of Clean Air Act Prevention of Significant Deterioration Permit Issued to Avenal Power...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-09

    ... AGENCY 40 CFR Part 52 Approval of Clean Air Act Prevention of Significant Deterioration Permit Issued to Avenal Power Center, LLC To Construct the Avenal Energy Project AGENCY: Environmental Protection Agency... decision granting the Clean Air Act Prevention of Significant Deterioration (PSD) permit...

  10. 75 FR 68093 - Partial Grant and Partial Denial of Clean Air Act Waiver Application Submitted by Growth Energy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-04

    ... Protection Agency Partial Grant and Partial Denial of Clean Air Act Waiver Application Submitted by Growth Energy To Increase the Allowable Ethanol Content of Gasoline to 15 Percent; Decision of the Administrator...; ] ENVIRONMENTAL PROTECTION AGENCY Partial Grant and Partial Denial of Clean Air Act Waiver Application...

  11. 75 FR 55791 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-14

    ... AGENCY Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for Alliant Energy--WPL Edgewater Generating Station AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of final order on petition to object to Clean Air Act operating permit. SUMMARY: This...

  12. 77 FR 5009 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for Duke...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ... object to a Clean Air Act (Act) Title V operating permit for Duke Energy Indiana--Edwardsport Generating... AGENCY Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for Duke Energy Indiana--Edwardsport Generating Station AGENCY: Environmental Protection Agency (EPA)....

  13. 76 FR 43684 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-21

    ... Energy (Xcel)--Pawnee Power Station. Pursuant to section 505(b)(2) of the Clean Air Act (Act or CAA... AGENCY Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for Public Service Company of Colorado dba Xcel Energy--Pawnee Power Station AGENCY: Environmental...

  14. ESTIMATES OF THE ATMOSPHERIC DEPOSITION OF SULFUR AND NITROGEN SPECIES: CLEAN AIR STATUS AND TRENDS NETWORK. 1990 THROUGH 2000

    EPA Science Inventory

    The Clean Air Status and Trends Network (CASTNet) was established by EPA in response to the requirements of the 1990 Clean Air Act Amendments. To satisfy these requirements CASTNet was designed to assess and report on geographic patterns and long-term, temporal trends in ambient ...

  15. 76 FR 23809 - Science Advisory Board Staff Office Notification of a Public Meeting of the Clean Air Scientific...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-28

    ... AGENCY Science Advisory Board Staff Office Notification of a Public Meeting of the Clean Air Scientific... announces a public meeting on May 19 and 20, 2011, of the Clean Air Scientific Advisory Committee (CASAC... Standards: Scope and Methods Plan for Health Risk and Exposure Assessment (April 2011 Draft), and...

  16. 76 FR 12730 - Clean Air Act Operating Permit Program; Objection to State Operating Permit for U.S. Steel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-08

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Clean Air Act Operating Permit Program; Objection to State Operating Permit for U.S. Steel-Granite.... Steel--Granite City Works (USS). Sections 307(b) and 505(b)(2) of the Clean Air Act (Act) provide that...

  17. 75 FR 19968 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-16

    ... AGENCY Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for... April 1, 2009 title V permit issued to Public Service Company of Colorado dba Xcel Energy (Xcel)--Hayden Power Station. Pursuant to section 505(b)(2) of the Clean Air Act (Act), Petitioners may seek...

  18. Alternating-Current Equipment for the Measurement of Fluctuations of Air Speed in Turbulent Flow

    NASA Technical Reports Server (NTRS)

    Mock, W C , Jr

    1937-01-01

    Recent electrical and mechanical improvements have been made in the equipment developed at the National Bureau of Standards for measurement of fluctuations of air speed in turbulent flow. Data useful in the design of similar equipment are presented. The design of rectified alternating-current power supplies for such apparatus is treated briefly, and the effect of the power supplies on the performance of the equipment is discussed.

  19. Understand the limitations of air/water testing of distillation equipment

    SciTech Connect

    Bennett, D.L.; Ludwig, K.A. )

    1994-04-01

    Distillation continues to be a unit operation of major importance--and a dynamic area for technical development. The designs of trays and packings are rapidly evolving, and the application of equipment also is changing. As chemical processes are pushed to become more efficient and lower cost, a general reduction in the traditional values for equipment safety factors are being seen. The net results is that one now has a greater need for a more thorough and fundamental understanding of distillation equipment. One technique to improve the understanding of distillation equipment is air/water testing. Such testing of distillation trays has become very common, and air/water test results for packed columns also are being reported. In this article, the authors will provide some guidance on how to assess the validity of such tests to industrial applications. In addition, they will discuss several possible approaches to test--and develop confidence in--the design of distillation equipment.

  20. 75 FR 34647 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-18

    .... See 64 FR 67793. Continuous web cleaning machines are solvent cleaning machines in which parts such as... FR 49839. Accordingly, RI DEM has satisfied the up-front approval criteria of 40 CFR 63.91(d...'s proposed Subpart E amendments on January 12, 1999. See 64 FR 1908. IV. EPA Determination of...

  1. A Multilevel Test of Constrained Choices Theory: The Case of Tobacco Clean Air Restrictions.

    PubMed

    Vuolo, Mike; Kadowaki, Joy; Kelly, Brian C

    2016-09-01

    According to Bird and Rieker's sociology of constrained choices, decisions and priorities concerning health are shaped by the contexts-including policy, community, and work/family-in which they are formulated. While each level received attention in the original and subsequent research, we contend their constrained choices theory provides a powerful multilevel framework for modeling health outcomes. We apply this framework to tobacco clean air restrictions, combining a comprehensive database of tobacco policies with the National Longitudinal Survey of Youth 1997 from ages 19 to 31. Using multilevel panel models, we find that clean air policies lower the odds of past 30 day smoking and dependence while controlling for other policy-, city-, and individual-level constraints. We also find unique between- and within-person effects, as well as gender effects, for the constraint levied by smoking bans. We argue for the theory's broad applicability beyond commonly cited findings regarding gender and biological influences. PMID:27601410

  2. A Multilevel Test of Constrained Choices Theory: The Case of Tobacco Clean Air Restrictions.

    PubMed

    Vuolo, Mike; Kadowaki, Joy; Kelly, Brian C

    2016-09-01

    According to Bird and Rieker's sociology of constrained choices, decisions and priorities concerning health are shaped by the contexts-including policy, community, and work/family-in which they are formulated. While each level received attention in the original and subsequent research, we contend their constrained choices theory provides a powerful multilevel framework for modeling health outcomes. We apply this framework to tobacco clean air restrictions, combining a comprehensive database of tobacco policies with the National Longitudinal Survey of Youth 1997 from ages 19 to 31. Using multilevel panel models, we find that clean air policies lower the odds of past 30 day smoking and dependence while controlling for other policy-, city-, and individual-level constraints. We also find unique between- and within-person effects, as well as gender effects, for the constraint levied by smoking bans. We argue for the theory's broad applicability beyond commonly cited findings regarding gender and biological influences.

  3. Analysis of S.1844, the Clear Skies Act of 2003; S. 843, the Clean Air Planning Act of 2003; and S. 366, the Clean Power Act of 2003

    EIA Publications

    2004-01-01

    Senator James M. Inhofe requested that the Energy Information Administration (EIA) undertake analysis of S.843, the Clean Air Planning Act of 2003, introduced by Senator Thomas Carper; S.366, the Clean Power Act of 2003, introduced by Senator James Jeffords; and S.1844, the Clear Skies Act of 2003, introduced by Senator James M. Inhofe. The EIA received this request on March 19, 2004. This Service Report responds to his request.

  4. 40 CFR 49.4 - Clean Air Act provisions for which it is not appropriate to treat tribes in the same manner as...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false Clean Air Act provisions for which it... PLANNING AND MANAGEMENT Tribal Authority § 49.4 Clean Air Act provisions for which it is not appropriate to... following provisions of the Clean Air Act and any implementing regulations thereunder: (a) Specific...

  5. 40 CFR 49.4 - Clean Air Act provisions for which it is not appropriate to treat tribes in the same manner as...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Clean Air Act provisions for which it... PLANNING AND MANAGEMENT Tribal Authority § 49.4 Clean Air Act provisions for which it is not appropriate to... following provisions of the Clean Air Act and any implementing regulations thereunder: (a) Specific...

  6. 40 CFR 49.4 - Clean Air Act provisions for which it is not appropriate to treat tribes in the same manner as...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Clean Air Act provisions for which it... PLANNING AND MANAGEMENT Tribal Authority § 49.4 Clean Air Act provisions for which it is not appropriate to... following provisions of the Clean Air Act and any implementing regulations thereunder: (a) Specific...

  7. 40 CFR 49.4 - Clean Air Act provisions for which it is not appropriate to treat tribes in the same manner as...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 1 2013-07-01 2013-07-01 false Clean Air Act provisions for which it... PLANNING AND MANAGEMENT Tribal Authority § 49.4 Clean Air Act provisions for which it is not appropriate to... following provisions of the Clean Air Act and any implementing regulations thereunder: (a) Specific...

  8. 40 CFR 62.14480 - Does this subpart require me to obtain an operating permit under title V of the Clean Air Act and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... an operating permit under title V of the Clean Air Act and implementing regulations? 62.14480 Section... the Clean Air Act and implementing regulations? This subpart requires you to obtain an operating permit under title V of the Clean Air Act and implementing regulations (“title V permit”) unless you...

  9. 40 CFR 62.14480 - Does this subpart require me to obtain an operating permit under title V of the Clean Air Act and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... an operating permit under title V of the Clean Air Act and implementing regulations? 62.14480 Section... the Clean Air Act and implementing regulations? This subpart requires you to obtain an operating permit under title V of the Clean Air Act and implementing regulations (“title V permit”) unless you...

  10. 40 CFR 49.4 - Clean Air Act provisions for which it is not appropriate to treat tribes in the same manner as...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Clean Air Act provisions for which it... Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE TRIBAL CLEAN AIR ACT AUTHORITY Tribal Authority § 49.4 Clean Air Act provisions for which it is not appropriate to treat tribes in...

  11. 76 FR 54465 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-01

    ...In accordance with section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), notice is hereby given of a proposed settlement agreement to address a lawsuit filed by Sierra Club and WildEarth Guardians in the United States District Court for the Northern District of California: Sierra Club et al. v. Jackson, No. 3:10-cv-04060-CRB (N.D. Cal.). On August 10, 2011, Plaintiffs filed......

  12. 40 CFR 2.301 - Special rules governing certain information obtained under the Clean Air Act.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... sections 114(c) and 307(d) of the Clean Air Act that information submitted under 40 CFR part 98 is entitled... submitted under 40 CFR part 98. (1) Sections 2.201 through 2.215 do not apply to data submitted under 40 CFR... (d)(4) of this section, §§ 2.201 through 2.215 do not apply to data submitted under 40 CFR part...

  13. 40 CFR 2.301 - Special rules governing certain information obtained under the Clean Air Act.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sections 114(c) and 307(d) of the Clean Air Act that information submitted under 40 CFR part 98 is entitled... submitted under 40 CFR part 98. (1) Sections 2.201 through 2.215 do not apply to data submitted under 40 CFR... (d)(4) of this section, §§ 2.201 through 2.215 do not apply to data submitted under 40 CFR part...

  14. 40 CFR 2.301 - Special rules governing certain information obtained under the Clean Air Act.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sections 114(c) and 307(d) of the Clean Air Act that information submitted under 40 CFR part 98 is entitled... submitted under 40 CFR part 98. (1) Sections 2.201 through 2.215 do not apply to data submitted under 40 CFR... (d)(4) of this section, §§ 2.201 through 2.215 do not apply to data submitted under 40 CFR part...

  15. Proactive industrial strategies for the Clean Air Act Amendments of 1990.

    PubMed

    Ruch, R B; Howell, J S

    1991-07-01

    The Clean Air Act (CAA) Amendments of 1990 was signed into law by President Bush on November 15, 1990. These amendments potentially will have a major impact on virtually every industrial and many commercial facilities throughout the country. The regulations developed to implement this legislation will encompass new approaches to nonattainment, air toxics, accidental releases, acid rain, permits and enforcement. Because of the impact of this legislation the regulations will be implemented over a ten-year period. This paper is an overview of the amendments and recommended proactive strategies for industry.

  16. Clean air and energy: from conflict to reconciliation. [Cost benefit analysis

    SciTech Connect

    Kolstad, C.D.; Schulze, W.D.; Williams, M.D.

    1982-01-01

    Unconstrained energy resource development in the Rocky Mountain west is likely to threaten the environment and the health and well-being of the people. Impacts may be associated with visibility degradation, toxic concentrations of gases, and deposition of acidic or toxic substances. Because the possible benefits of energy development in the region are very large, there is great concern that constraints imposed by air quality regulation may preclude the use of important resources or make unduly expensive energy produced from the region. The conflict between energy and clean air in the region is exacerbated by non-energy sources, such as copper smelters and urban areas, that already pose significant environmental threats. The hard policy question is not how to preserve clean air resources or how to develop energy but how to achieve and balance both goals. The effects and regulatory costs and benefits of air pollution control are discussed, and policy directions to protect air quality while pursuing energy development are presented.

  17. 75 FR 65480 - Science Advisory Board Staff Office; Notification of Two Public Teleconferences of the Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-25

    ... teleconferences of the Clean Air Scientific Advisory Committee NO X and SO x Secondary National Ambient Air... is hereby given that the CASAC NO X & SO X Secondary NAAQS Review Panel will hold a teleconference on... Assessment supporting development of secondary National Ambient Air Quality Standards (NAAQS) for NO X and...

  18. Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozone

    NASA Astrophysics Data System (ADS)

    Singer, Brett C.; Coleman, Beverly K.; Destaillats, Hugo; Hodgson, Alfred T.; Lunden, Melissa M.; Weschler, Charles J.; Nazaroff, William W.

    This study investigated the formation of secondary pollutants resulting from household product use in the presence of ozone. Experiments were conducted in a 50-m 3 chamber simulating a residential room. The chamber was operated at conditions relevant to US residences in polluted areas during warm-weather seasons: an air exchange rate of 1.0 h -1 and an inlet ozone concentration of approximately 120 ppb, when included. Three products were used in separate experiments. An orange oil-based degreaser and a pine oil-based general-purpose cleaner were used for surface cleaning applications. A plug-in scented-oil air freshener (AFR) was operated for several days. Cleaning products were applied realistically with quantities scaled to simulate residential use rates. Concentrations of organic gases and secondary organic aerosol from the terpene-containing consumer products were measured with and without ozone introduction. In the absence of reactive chemicals, the chamber ozone level was approximately 60 ppb. Ozone was substantially consumed following cleaning product use, mainly by homogeneous reaction. For the AFR, ozone consumption was weaker and heterogeneous reaction with sorbed AFR-constituent VOCs was of similar magnitude to homogeneous reaction with continuously emitted constituents. Formaldehyde generation resulted from product use with ozone present, increasing indoor levels by the order of 10 ppb. Cleaning product use in the presence of ozone generated substantial fine particle concentrations (more than 100 μg m -3) in some experiments. Ozone consumption and elevated hydroxyl radical concentrations persisted for 10-12 h following brief cleaning events, indicating that secondary pollutant production can persist for extended periods.

  19. Cleaning Products and Air Fresheners: Emissions and ResultingConcentrations of Glycol Ethers and Terpenoids

    SciTech Connect

    Singer, Brett C.; Destaillat, Hugo; Hodgson, Alfred T.; Nazaroff,William W.

    2005-08-01

    Experiments were conducted to quantify emissions and concentrations of glycol ethers and terpenoids from cleaning product and air freshener use in a 50-m{sup 3} room ventilated at {approx}0.5 h{sup -1}. Five cleaning products were applied full-strength (FS); three were additionally used in dilute solution. FS application of pine-oil cleaner (POC) yielded 1-h concentrations of 10-1300 {micro}g m{sup -3} for individual terpenoids, including {alpha}-terpinene (90-120), d-limonene (1000-1100), terpinolene (900-1300), and {alpha}-terpineol (260-700). One-hour concentrations of 2-butoxyethanol and/or dlimonene were 300-6000 {micro}g m{sup -3} after FS use of other products. During FS application including rinsing with sponge and wiping with towels, fractional emissions (mass volatilized/dispensed) of 2-butoxyethanol and d-limonene were 50-100% with towels retained, {approx}25-50% when towels were removed after cleaning. Lower fractions (2-11%) resulted from dilute use. Fractional emissions of terpenes from FS use of POC were {approx}35-70% with towels retained, 20-50% with towels removed. During floor cleaning with dilute solution of POC, 7-12% of dispensed terpenes were emitted. Terpene alcohols were emitted at lower fractions: 7-30% (FS, towels retained), 2-9% (FS, towels removed), and 2-5% (dilute). During air-freshener use, d-limonene, dihydromyrcenol, linalool, linalyl acetate, and {beta}-citronellol were emitted at 35-180 mg d{sup -1} over three days while air concentrations averaged 30-160 {micro}g m{sup -3}.

  20. 76 FR 14427 - Revision to Notice of Lodging of Settlement Agreement Under the Clean Air Act, Comprehensive...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-16

    .../Notices/page 13208). Maureen Katz, Assistant Section Chief, Environmental Enforcement Section, Environment... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF JUSTICE Revision to Notice of Lodging of Settlement Agreement Under the Clean Air Act, Comprehensive...

  1. 77 FR 58988 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-25

    ... (Petition), submitted under title V of the Clean Air Act (Act) by WildEarth Guardians (Petitioner), to.... EPA received a petition from WildEarth Petitioner dated August 4, 2011, requesting that EPA object...

  2. The enforcement provisions of the Clean Air Act - not the same old Section 113

    SciTech Connect

    Benthul, H.R.

    1996-08-01

    The Clean Air Act ({open_quotes}CAA{close_quotes}) of 1990 was in many respects a major overhaul of the previous versions of the Clean Air Act although it retained most of the preexisting major programs such as the basic National Ambient Air Quality Standards ({open_quotes}NAAQS{close_quotes}) scheme, PSD, new source performance standards, regulation of toxic air pollutants, and the like. The 1990 Act strengthened the enforcement provisions of the Act by enhancing the enforcement powers of the Environmental Protection Agency ({open_quotes}EPA{close_quotes}) of {section}113. For example, the criminal enforcement provisions of {section}113 are expanded both in the range of punishment and in the kinds of activities which are subject to criminal enforcement. Moreover, the Act now contains a number of additional enforcement provisions in addition to those found in {section}113. The purpose of this paper is to discuss both the {section}113 provision and as well, identify those enforcement provisions found outside {section}113. The latter provisions will be taken up first and addressed by Titles of the Act. The discussion of specific sections and subsections of the CAA are necessarily brief and in the nature of highlighting of particular features; like the rest of the CAA, careful reading and analysis is a requirement for full understanding.

  3. A public health context for residual risk assessment and risk management under the clean air act.

    PubMed

    Charnley, G; Goldstein, B D

    1998-09-01

    The 1990 amendments to the Clean Air Act required the EPA to institute new pollution control technology requirements for industrial sources of air pollution. In part because agreement could not be reached on the best way for the EPA to determine whether any significant risks to human health will remain after the technology controls are in place, the amendments also created a Commission on Risk Assessment and Risk Management and gave the commission a broad mandate to review and make recommendations concerning risk assessment and risk management in federal regulatory programs. In its March 1997 final report to Congress and the administration, the commission recommended a tiered approach to assessing such residual risks. That approach included the idea that when decisions about managing residual risks are made, emissions should be evaluated in the context of other sources of air pollution. Evaluating risks in their larger contexts is consistent with what the commission called a public health approach to environmental risk management. This paper describes the public health approach and how it applies to evaluating residual risks under the Clean Air Act. PMID:9721251

  4. Proceedings of the 21st DOE/NRC nuclear air cleaning conference; Volume 2, Sessions 9--16

    SciTech Connect

    First, M.W.

    1991-02-01

    The 21st meeting of the Department of Energy/Nuclear Regulatory Commission (DOE/NRC) Nuclear Air Cleaning Conference was held in San Diego, CA on August 13--16, 1990. The proceedings have been published as a two volume set. Volume 2 contains sessions covering adsorbents, nuclear codes and standards, modelling, filters, safety, containment venting and a review of nuclear air cleaning programs around the world. Also included is the list of attendees and an index of authors and speakers. (MHB)

  5. 76 FR 54462 - Notification of a Public Teleconference; Clean Air Scientific Advisory Committee; Air Monitoring...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-01

    ... network in support of a newly revised National Ambient Air Quality Standard (NAAQS) for 1-hour NO 2 (75 FR... or topography, meteorology, population exposure and other factors in determining where a...

  6. Evaluation of control parameters for Spray-In-Air (SIA) aqueous cleaning for shuttle RSRM hardware

    NASA Technical Reports Server (NTRS)

    Davis, S. J.; Deweese, C. D.

    1995-01-01

    HD-2 grease is deliberately applied to Shuttle Redesigned Solid Rocket Motor (RSRM) D6AC steel hardware parts as a temporary protective coating for storage and shipping. This HD-2 grease is the most common form of surface contamination on RSRM hardware and must be removed prior to subsequent surface treatment. Failure to achieve an acceptable level of cleanliness (HD-2 calcium grease removal) is a common cause of defect incidence. Common failures from ineffective cleaning include poor adhesion of surface coatings, reduced bond performance of structural adhesives, and failure to pass cleanliness inspection standards. The RSRM hardware is currently cleaned and refurbished using methyl chloroform (1,1,1-trichloroethane). This chlorinated solvent is mandated for elimination due to its ozone depleting characteristics. This report describes an experimental study of an aqueous cleaning system (which uses Brulin 815 GD) as a replacement for methyl chloroform. Evaluation of process control parameters for this cleaner are discussed as well as cleaning mechanisms for a spray-in-air process.

  7. The politics of markets: The acid rain control policy in the 1990 Clean Air Act amendments

    SciTech Connect

    Kete, N.

    1993-01-01

    This thesis is a review and critique of the development of the acid rain control policy codified as Title IV of the Clean Air Act. The amendments include provisions to address acid rain-air pollution that has been transformed and transported over long distances. Title IV also embodies the first large scale adoption of market principles and economic incentives in the cause of environmental protection. The acid rain control amendments are being hailed as a break with past environmental protection practice and are being offered as a model for further regulatory reform. The thesis looks at the roots of the acid rain policy and considers the set of legal, social, and economic relations embedded in the policy which define the nature of its legal controls over pollution and its inverse, environmental quality. It explores whether the creation of the emissions allowance trading system changes the social relationships that prevailed under the pre-amended Clean Air Act. It responds to and rebuts the concerns of some critics that the policy represents an alienation of the public's right to clean air. A review of the acid rain policymaking process provides a recent and concrete example of the two central concerns inherent in public policy: the making of decisions that establish institutional arrangements, or structures, that both constrain and liberate individual action at the operational level; and the search for the boundary between autonomous behavior and collective decision making. The policy responds to regulatory reform recommendations concerned with improving the effectiveness, accountability, and cost-effectiveness of environmental protection. As a model for future policymaking, the policy goes beyond and encompasses more than the welfare economics ideal of static economic efficiency and the [open quotes]free market environmentalism[close quotes] emphasis on private property and common law.

  8. Interaction between Titles 2 and 3 of the Clean Air Act as amended, 1990

    SciTech Connect

    Szpunar, C.B.

    1996-02-01

    This report examines Some issues that would I affect the refining industry if the requirements for hazardous air pollutants set out in Title III of the Clean Air Act Amendments were to impede the market entrance of oxygenated fuels, as me; required by Title II. It describes the mandate for reformulated gasoline; considers gasoline characteristics in light of component shifts in refining; examines the supply of, demand for, and cost of various feedstocks and blendstocks; and identifies the emissions and atmospheric impacts that might result from the production and use of reformulated gasoline. Attention is focused on methanol and MTBE, two potential blendstocks that are also hazardous air pollutants, and on maximum achievable control technology standards, which might be applied to the stationary sources that produce them.

  9. New clean air efforts face tough challenges, say senators and former EPA administrators

    NASA Astrophysics Data System (ADS)

    Showstack, Randy

    2012-02-01

    With the U.S. Environmental Protection Agency (EPA) coming under repeated attack from some members of Congress and others for perceived heavy-handed regulatory actions, two moderate U.S. senators and two former EPA administrators recently noted the need for continued measures to improve air quality. However, they also acknowledged the difficulty in moving forward with new legislative efforts to revise the federal Clean Air Act to further reduce air pollution in the current polarized political climate. "Nobody who wants to see constructive changes [to the act] would dare touch it or propose it in the current climate," said former EPA administrator William Reilly at a 23 January forum sponsored by the World Resources Institute. Reilly, who served as EPA administrator from 1989 to 1992, noted that bipartisan congressional support had been key to addressing many environmental problems up until the mid-1990s.

  10. An Analysis of Price Determination and Markups in the Air-Conditioning and Heating Equipment Industry

    SciTech Connect

    Dale, Larry; Millstein, Dev; Coughlin, Katie; Van Buskirk, Robert; Rosenquist, Gregory; Lekov, Alex; Bhuyan, Sanjib

    2004-01-30

    In this report we calculate the change in final consumer prices due to minimum efficiency standards, focusing on a standard economic model of the air-conditioning and heating equipment (ACHE) wholesale industry. The model examines the relationship between the marginal cost to distribute and sell equipment and the final consumer price in this industry. The model predicts that the impact of a standard on the final consumer price is conditioned by its impact on marginal distribution costs. For example, if a standard raises the marginal cost to distribute and sell equipment a small amount, the model predicts that the standard will raise the final consumer price a small amount as well. Statistical analysis suggest that standards do not increase the amount of labor needed to distribute equipment the same employees needed to sell lower efficiency equipment can sell high efficiency equipment. Labor is a large component of the total marginal cost to distribute and sell air-conditioning and heating equipment. We infer from this that standards have a relatively small impact on ACHE marginal distribution and sale costs. Thus, our model predicts that a standard will have a relatively small impact on final ACHE consumer prices. Our statistical analysis of U.S. Census Bureau wholesale revenue tends to confirm this model prediction. Generalizing, we find that the ratio of manufacturer price to final consumer price prior to a standard tends to exceed the ratio of the change in manufacturer price to the change in final consumer price resulting from a standard. The appendix expands our analysis through a typical distribution chain for commercial and residential air-conditioning and heating equipment.

  11. Using PHM to measure equipment usable life on the Air Force's next generation reusable space booster

    NASA Astrophysics Data System (ADS)

    Blasdel, A.

    The U.S. Air Force procures many launch vehicles and launch vehicle services to place their satellites at their desired location in space. The equipment on-board these satellite and launch vehicle often suffer from premature failures that result in the total loss of the satellite or a shortened mission life sometimes requiring the purchase of a replacement satellite and launch vehicle. The Air Force uses its EELV to launch its high priority satellites. Due to a rise in the cost of purchasing a launch using the Air Force's EELV from 72M in 1997 to as high as 475M per launch today, the Air Force is working to replace the EELV with a reusable space booster (RSB). The RSB will be similar in design and operations to the recently cancelled NASA reusable space booster known as the Space Shuttle. If the Air Force uses the same process that procures the EELV and other launch vehicles and satellites, the RSB will also suffer from premature equipment failures thus putting the payloads at a similar high risk of mission failure. The RSB is expected to lower each launch cost by 50% compared to the EELV. The development of the RSB offers the Air Force an opportunity to use a new reliability paradigm that includes a prognostic and health management program and a condition-based maintenance program. These both require using intelligent, decision making self-prognostic equipment The prognostic and health management program and its condition-based maintenance program allows increases in RSB equipment usable life, lower logistics and maintenance costs, while increasing safety and mission assurance. The PHM removes many decisions from personnel that, in the past resulted in catastrophic failures and loss of life. Adding intelligent, decision-making self-prognostic equipment to the RSB will further decrease launch costs while decreasing risk and increasing safety and mission assurance.

  12. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed...

  13. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed...

  14. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed...

  15. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed...

  16. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed...

  17. Surface cleaning of metals in air with a one atmosphere uniform glow discharge plasma

    SciTech Connect

    Roth, J.R.; Ku, Y.

    1995-12-31

    The authors report the use of active species generated in a one atmosphere uniform glow discharge plasma reactor with a parallel-plate configuration to clean the surface of as-received metal samples from the machine shop floor. The experimental arrangement used to expose the 7 by 10 cm metal samples is shown. The lower parallel-plate electrode is a flat copper plate 22 by 22 cm, covered by a 5mm thick pyrex sheet. The upper electrode is formed by the bare metal sample plate, with the side to be cleaned facing the plasma. To assure plasma uniformity between the electrodes, it was helpful to direct a flow of air on the edges of the plasma volume. The cleanliness of the metal samples was determined with the standard sessile water drop test.

  18. EMISSIONS OF AIR TOXICS FROM A SIMULATED CHARCOAL KILN EQUIPPED WITH AN AFTERBURNER

    EPA Science Inventory

    The report discusses emissions of air toxics from a simulated charcoal kiln equipped with an afterburner. A laboratory-scale simulator was constructed and tested to determine if it could be used to produce charcoal that was similar to that produced in Missouri-type charcoal kilns...

  19. 77 FR 3323 - Airborne Radar Altimeter Equipment (For Air Carrier Aircraft)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-23

    ... [Federal Register Volume 77, Number 14 (Monday, January 23, 2012)] [Notices] [Pages 3323-3324] [FR... Engineering Division, Aircraft Certification Service. [FR Doc. 2012-1243 Filed 1-20-12; 8:45 am] BILLING CODE... Altimeter Equipment (For Air Carrier Aircraft) AGENCY: Federal Aviation Administration (FAA), DOT....

  20. MTR COMPRESSOR BUILDING, TRA651. RELATED AIR COMPRESSOR EQUIPMENT OUTSIDE BUILDING. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR COMPRESSOR BUILDING, TRA-651. RELATED AIR COMPRESSOR EQUIPMENT OUTSIDE BUILDING. PIPE LEADS BELOW GRADE INTO MTR BUILDING. CAMERA FACING WEST, IE, EAST SIDE OF MTR BUILDING. INL NEGATIVE NO. 56-1265. Jack L. Larsen, Photographer, 4/20/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  1. Clearing the Air: The Impact of the Clean Air Act on Technology.

    ERIC Educational Resources Information Center

    Redmond, John C., Ed.; And Others

    This compendium has been prepared to summarize the notable aspects of the U. S. Clear Air Amendments of 1970 for members of the Institute of Electrical and Electronics Engineers and others. The work is not a complete explanation of the law and all of its ramifications; it is, rather, an expedient means to gain rapid insight into the more…

  2. A PRINCIPAL COMPONENT ANALYSIS OF THE CLEAN AIR STATUS AND TRENDS NETWORK (CASTNET) AIR CONCENTRATION DATA

    EPA Science Inventory

    The spatial and temporal variability of ambient air concentrations of SO2, SO42-, NO3, HNO3, and NH4+ obtained from EPA's CASTNet was examined using an objective, statistically based technique...

  3. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and...

  4. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and...

  5. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and...

  6. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and...

  7. 40 CFR 49.5 - Tribal requests for additional Clean Air Act provisions for which it is not appropriate to treat...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Tribal requests for additional Clean... additional Clean Air Act provisions for which it is not appropriate to treat tribes in the same manner as States. Any tribe may request that the Administrator specify additional provisions of the Clean Air...

  8. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and...

  9. Investigation of the Shockley surface state on clean and air-exposed Au (1 1 1)

    NASA Astrophysics Data System (ADS)

    Kowalczyk, P. J.; Puchalski, M.; Kozłowski, W.; Dąbrowski, P.; Klusek, Z.; Olejniczak, W.

    2008-05-01

    Scanning tunneling microscopy (STM) and spectroscopy (STS) carried out in vacuum and air were used to study the electronic structure of the Au (1 1 1) surface in the range of 0.0-0.7 eV below the Fermi level. The STS experiment carried out in UHV showed the existence of the Shockley surface state (SS) located 0.48 eV below the Fermi level. STS carried out in air showed strong local maximum located 0.35 eV below the Fermi level. This maximum was ascribed to the SS shifted toward lower energy due to carbon and oxygen overlayer. To confirm that the SS could exist on the sample exposed to air we did ultraviolet photoemission spectroscopy (UPS) experiment on air-treated and clean Au (1 1 1). Our results suggest that the SS position initially measured at 0.38 eV below the Fermi level was shifted to 0.27 eV after air treatment. Additionally, the level of contamination was measured using X-ray photoelectron spectroscopy (XPS).

  10. 76 FR 16768 - Science Advisory Board Staff Office; Notification of a Public Teleconference of the Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-25

    ... Scientific Advisory Committee (CASAC) AGENCY: Environmental Protection Agency (EPA). ACTION: Notice. SUMMARY... teleconference of the Clean Air Scientific Advisory Committee (CASAC) to conduct a quality review and approve... (NO X -SO X Panel) and the CASAC Air Monitoring and Methods Subcommittee (AMMS). DATES: The...

  11. The North Carolina Department of Environment and Natural Resources: clean land, water, and air for healthy people and communities.

    PubMed

    Riegel, Lisa Diaz; Wakild, Charles; Boothe, Laura; Hildebrandt, Heather J; Nicholson, Bruce

    2012-01-01

    The North Carolina Department of Environment and Natural Resources works with communities and other agencies to sustain clean air, water, and land. Sustainability efforts include protecting air quality through community design, community enhancement through brownfields revitalization, community development strategies to protect water resources, and the integration of natural resource conservation.

  12. 77 FR 27054 - Notice of Approval of Clean Air Act Outer Continental Shelf Permits Issued to Shell Offshore, Inc...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-08

    ... AGENCY Notice of Approval of Clean Air Act Outer Continental Shelf Permits Issued to Shell Offshore, Inc. for the Kulluk Conical Drilling Unit AGENCY: United States Environmental Protection Agency (EPA... Title V air quality operating permit to Shell Offshore, Inc. (``Shell'') for operation of the...

  13. Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system.

    PubMed

    Bonetta, Sa; Bonetta, Si; Mosso, S; Sampò, S; Carraro, E

    2010-02-01

    The purpose of this study was to evaluate the level and composition of bacteria and fungi in the indoor air of an Italian office building equipped with a heating, ventilation and air conditioning (HVAC) system. Airborne bacteria and fungi were collected in three open-space offices during different seasons. The microbial levels in the outdoor air, supply air diffusers, fan coil air flow and air treatment unit humidification water tank were used to evaluate the influence of the HVAC system on indoor air quality (IAQ). A medium-low level of bacterial contamination (50-500 CFU/m(3)) was found in indoor air. Staphylococcus and Micrococcus were the most commonly found genera, probably due to human presence. A high fungal concentration was measured due to a flood that occurred during the winter. The indoor seasonal distribution of fungal genera was related to the fungal outdoor distribution. Significant seasonal and daily variation in airborne microorganisms was found, underlining a relationship with the frequency of HVAC system switching on/off. The results of this monitoring highlight the role of the HVAC system on IAQ and could be useful to better characterise bacterial and fungal population in the indoor air of office buildings.

  14. Evaluating the Impact of Air Pollution on Human Health in China: the Price of Clean Air

    NASA Astrophysics Data System (ADS)

    Wang, X.; Mauzerall, D. L.; Hu, Y.; Russell, A. G.; Woo, J.; Streets, D. G.

    2003-12-01

    Population growth, rapid urbanization and economic development are contributing to increased energy consumption in China. One of the unintended consequences is poor air quality due to a lack of environmental controls. The coal dependent energy structure in China only worsens the situation. Quantification of the environmental costs resulting from air pollution is needed in order to provide a mechanism for making strategic energy policy that accounts for the life-cycle cost of energy use. However, few such studies have been conducted for China that examine the entire energy system. Here we examine the extent to which public health has been compromised due to elevated air pollution and how China could incorporate environmental costs into future energy and environmental policies. Taking the Shandong region in eastern China as a case study, we develop a high-resolution regional inventory for anthropogenic emissions of NOx, CO, PM2.5, PM10, VOCs, NH3 and SO2. SMOKE (Sparse Matrix Operator Kernel Emissions Modeling System) is used to process spatial and temporal distributions and chemical speciation of the regional emissions, MM5 (the Fifth-Generation NCAR/Penn State Meso-scale Model, Version 3) is used to generate meteorology and Models3/CMAQ (Community Multi-scale Air Quality Modeling System) is used to simulate ambient concentrations of particulates and other gaseous species in this region. We then estimate the mortality and morbidity in this region resulting from exposure to these air pollutants. We also estimate the monetary values associated with the resulting mortality and morbidity and quantify the contributions from various economic sectors (i.e. power generation, transportation, industry, residential and others). Finally, we examine the potential health benefits that adoption of best available or advanced energy (coal-based, in particular) and environmental technologies in different sectors could bring about. The results of these analyses are intended to provide

  15. Cleaning air from multicomponent impurities of volatile organic compounds by pulsed corona discharge

    NASA Astrophysics Data System (ADS)

    Filatov, I. E.; Uvarin, V. V.; Kuznetsov, D. L.

    2016-09-01

    The relative efficiency of the removal of impurities from airflow under the action of pulsed corona discharge has been studied by processing model mixtures of air with volatile organic compounds (VOCs). A method is proposed that allows the influence of the VOC structure on its reactivity to be directly determined. For this purpose, it is suggested to calculate a relative energy parameter characterizing the reactivity of a given impurity component in the framework of the method employed. This approach significantly intensifies the process of determination of the energy parameters of impurity removal and can be used as a criterion for comparative estimation of the efficiency of various methods employing nonequilibrium plasma for cleaning air from VOCs.

  16. The Clean Air Act strictly regulates electric utility emissions and utilities are reducing their emissions significantly

    SciTech Connect

    Kinsman, J.D.

    1998-12-31

    Electric utility SO{sub 2} and NO{sub x} emissions have been reduced tremendously, beginning before the first deadlines (1995 for SO{sub 2} and 1996 for NO{sub x}) of the 1990 Clean Air Act Amendments. For the Acid Rain Program, EPA reports that: (1) all 445 affected facilities demonstrated 100 percent compliance for both pollutants and even exceeded the compliance targets; (2) the Acid Rain Program has been very successful; and (3) due to these and other controls, air quality has improved in the United States. Furthermore, the new 8-hour ozone standard, the new PM2.5 standards, the EPA`s 22-state regional NO{sub x} program, the Northeast state petitions for upwind NO{sub x} reductions and EPA`s regional haze proposal will likely lead to substantially greater reductions of utility SO{sub 2} and NO{sub x}.

  17. Characterization of biogenic volatile organic compounds (BVOCs) in cleaning reagents and air fresheners in Hong Kong

    NASA Astrophysics Data System (ADS)

    Huang, Yu; Ho, Steven Sai Hang; Ho, Kin Fai; Lee, Shun Cheng; Gao, Yuan; Cheng, Yan; Chan, C. S.

    2011-11-01

    Biogenic volatile organic compounds (BVOCs) emitted from cleaning products and air fresheners indoors are prone to oxidation resulting in the formation of secondary pollutants that can pose health risks on residents. In this study, a solid phase microextraction (SPME) coupled with gas chromatography/mass spectrometry (SPME-GC/MS) method was applied for the determination of BVOCs compositions in three categories of cleaning products including floor cleaners (FC), kitchen cleaners (KC) and dishwashing detergents (DD), and also air fresheners (AF). The analysis results demonstrated that chemical composition and concentration of individual BVOC varied broadly with household products in the view of their different functions and scents as indicated on the labels. The concentration of total BVOCs for sample FC1 was the highest up to 4146.0 μg g -1, followed by FC2 of 264.6 μg g -1, FC4 of 249.3 μg g -1 and FC3 of 139.2 μg g -1. D-limonene was the most abundant detected BVOCs in KC samples with the chemical composition varying from 19.6 ± 1.0 to 1513.0 ± 37.1 μg g -1. For dishwashing detergents, only D-limonene was detected and quantified. The BVOCs compositions of air freshener samples are much more complicated. It was estimated that the consumption of floor cleaners contributed 51% of the total BVOCs amount indoors in Hong Kong, followed by air fresheners 42%, kitchen cleaners 5% and dishwashing detergents 2%.

  18. Revision of testing criteria for air cleaning unit of renovated APR-1000 and APR-1400 NPPS.

    PubMed

    Jeong, Seung-Young

    2011-07-01

    Designing Air Cleaning Units (ACU) of an Engineered Safety Feature and normal atmosphere clean-up system at the renovated APR-1000 and APR-1400 NPP, and fuel cycle facilities in Korea, is required to meet the standards of ASME AG-1 (1997), ASME N509/N510 (1989) and KEPIC-MH (2001) to enhance the removal efficiency of aerosols and particulates from the effluents. The revised ACU testing criteria are allowed to use alternative challenge agents of the dioctyl phthalate and Refrigerant-11 for in situ testing of high efficiency particulate air filters and adsorption banks. The operability testing time of engineered safety feature (ESF) trains was changed from 10 h to 15 min. The activated carbon in adsorption banks should undergo laboratory tests at a temperature of 30 °C and relative humidity 95 %. The removal criteria of methyl iodide should be over 99.5 % for ESF and 99 % for normal systems. This paper provides the background of the changed criteria for designing and testing of the ACU system in nuclear facilities.

  19. Association between Clean Indoor Air Laws and Voluntary Smokefree Rules in Homes and Cars

    PubMed Central

    Cheng, Kai-Wen; Okechukwu, Cassandra A.; McMillen, Robert; Glantz, Stanton A.

    2013-01-01

    Objectives This study examines the influence that smokefree workplaces, restaurants, and bars on the adoption of smokefree rules in homes and cars and whether the adoptions of home and car smokefree rule are associated. Methods Bivariate probit models were used to jointly estimate the likelihood of living in a smokefree home and having a smokefree car as a function of law coverage and other variables. Household data are from the nationally representative Social Climate Survey of Tobacco Control 2001, 2002, and 2004–2009; clean indoor air law data comes from the American Nonsmokers’ Rights Foundation Tobacco Control Laws Database. Results Both “full coverage” and “partial coverage” smokefree legislations are associated with an increased likelihood of having voluntary home and car smokefree rules compared with “no coverage”. The association between “full coverage” and smokefree rule in homes and cars is 5% and 4%, respectively, and the association between “partial coverage” and smokefree rule in homes and cars is 3% and 4%, respectively. There is a positive association between the adoption of home and car smokefree rules. Conclusions Clean indoor air laws provide the additional benefit of encouraging voluntary adoption of smokefree rules in homes and cars. PMID:24114562

  20. Cleaning level acceptance criteria and a high pressure liquid chromatography procedure for the assay of Meclizine Hydrochloride residue in swabs collected from pharmaceutical manufacturing equipment surfaces.

    PubMed

    Mirza, T; Lunn, M J; Keeley, F J; George, R C; Bodenmiller, J R

    1999-04-01

    A method using pharmacologically based and visual limit of detection criteria to determine the acceptable residue level for Meclizine Hydrochloride (MH) on pharmaceutical manufacturing equipment surfaces after cleaning is described. A formula was used in order to determine the pharmacologically safe cleaning level for MH. This level was termed as specific residual cleaning Level (SRCL) and calculated to be 50 microg 100 cm(-2). The visual limit of detection (VLOD) was determined by spiking different levels of MH on stainless steel plates and having the plates examined by a group of observers. The lowest level that could be visually detected by the majority of the observers, 62.5 microg 100 cm(-2), was considered as the VLOD for MH. The lower of the SRCL and VLOD values, i.e. 50 microg 100 cm(-2), was therefore chosen as the cleaning acceptance criterion. A sensitive reversed-phase HPLC method was developed and validated for the assay of MH in swabs used to test equipment surfaces. Using this method, the mean recoveries of MH from spiked swabs and '180-Grit' stainless steel plates were 87.0 and 89.5% with relative standard deviations (RSD) of +/- 3.3 and +/- 2.4%, respectively. The method was successfully applied to the assay of actual swab samples collected from the equipment surfaces. The stability of MH on stainless steel plates, on cleaning swabs and in the extraction solution was investigated. PMID:10698538

  1. Unusual basal skull fracture in a vehicle equipped with an air bag.

    PubMed

    Bandstra, R A; Carbone, L S

    2001-09-01

    A woman who was the lap/shoulder belt-restrained driver of a car equipped with a full-size air bag was involved in an oblique frontal collision with a tractor-trailer combination. She was extremely out of position, i.e., witnessed to be slumped over the steering wheel before impact. This preimpact positioning led to fatal injuries resulting from the inflating air bag. Postmortem examination showed an unusual partial ring fracture of the base of the skull, which to the authors' knowledge has not previously been reported.

  2. Unusual basal skull fracture in a vehicle equipped with an air bag.

    PubMed

    Bandstra, R A; Carbone, L S

    2001-09-01

    A woman who was the lap/shoulder belt-restrained driver of a car equipped with a full-size air bag was involved in an oblique frontal collision with a tractor-trailer combination. She was extremely out of position, i.e., witnessed to be slumped over the steering wheel before impact. This preimpact positioning led to fatal injuries resulting from the inflating air bag. Postmortem examination showed an unusual partial ring fracture of the base of the skull, which to the authors' knowledge has not previously been reported. PMID:11563734

  3. Development of an air cleaning system for dissolving high explosives from nuclear warheads

    SciTech Connect

    Bergman, W.; Wilson, K.; Staggs, K.; Wapman, D.

    1997-08-01

    The Department of Energy (DOE) has a major effort underway in dismantling nuclear weapons. In support of this effort we have been developing a workstation for removing the high explosive (HE) from nuclear warheads using hot sprays of dimethyl sulfoxide (DMSO) solvent to dissolve the HE. An important component of the workstation is the air cleaning system that is used to contain DMSO aerosols and vapor and radioactive aerosols. The air cleaning system consists of a condenser to liquefy the hot DMSO vapor, a demister pad to remove most of the DMSO aerosols, a high efficiency particulate air (HEPA) filter to remove the remaining aerosols, an activated carbon filter to remove the DMSO vapor, and a final HEPA filter to meet the redundancy requirement for HEPA filters in radioactive applications. The demister pad is a 4{double_prime} thick mat of glass and steel fibers and was selected after conducting screening tests on promising candidates. We also conducted screening tests on various activated carbons and found that all had a similar performance. The carbon breakthrough curves were fitted to a modified Wheeler`s equation and gave excellent predictions for the effect of different flow rates. After all of the components were assembled, we ran a series of performance tests on the components and system to determine the particle capture efficiency as a function of size for dioctyl sebacate (DOS) and DMSO aerosols using laser particle counters and filter samples. The pad had an efficiency greater than 990% for 0.1 {mu}m DMSO particles. Test results on the prototype carbon filter showed only 70% efficiency, instead of the 99.9% in small scale laboratory tests. Thus further work will be required to develop the prototype carbon filter. 7 refs., 18 figs., 10 tabs.

  4. Trials and tribulations implementing the Clean Air Act Title V in fourteen air districts

    SciTech Connect

    Moore, C.

    1998-12-31

    Santa Fe pacific Pipeline Partners, L.P. (SFPP) is a refined petroleum pipeline operating in six states in the western United States. Sixteen terminals are subject to the Title V permit to operate requirements. There are many obstacles to overcome, not only when preparing applications for Title V operating permits, but in the implementation phase of the project as well. Each Air District has its own set of rules and regulations that must be adhered to in preparing the application. For example, some districts required the insignificant sources to be documented and included in compliance plans and some do not. The format required for the application varies from stringent forms that must be completed to no forms at all. In preparing the Title V application for SFPP, the author quickly realized if this confusion was transferred to the implementation phase, compliance would be a failure. Therefore, early on the environmental manager instituted a training program. Beginning with a pilot program in one district the author began training managers and supervisors. This program quickly was expanded to include senior vice presidents and technicians. This training session was a one hour of general overview to visually describe how the Title V process would affect the facilities. As a result of this training, virtually every employee became familiar with how the Title V program was affecting the facilities. Engineering and Customer Service is instructed to notify the manager of any and every new project so it could undergo a review to determine if it affected a Title V facility. The field acts as a check of the system. Any change or modification at any facility is immediately under scrutiny for Title V implications. Another obstacle to overcome is to help the facility deal with something that is new and basically a different way of operating.

  5. 40 CFR 62.14441 - When must I inspect my HMIWI equipment and air pollution control devices?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and air pollution control devices? 62.14441 Section 62.14441 Protection of Environment ENVIRONMENTAL... my HMIWI equipment and air pollution control devices? (a) You must inspect your large, medium, small... inspect the air pollution control devices on your large, medium, small or small rural HMIWI by May...

  6. 40 CFR 62.14441 - When must I inspect my HMIWI equipment and air pollution control devices?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and air pollution control devices? 62.14441 Section 62.14441 Protection of Environment ENVIRONMENTAL... my HMIWI equipment and air pollution control devices? (a) You must inspect your large, medium, small... inspect the air pollution control devices on your large, medium, small or small rural HMIWI by May...

  7. CHARACTERIZATION OF OZONE EMISSIONS FROM AIR CLEANERS EQUIPPED WITH OZONE GENERATORS AND SENSOR AND FEEDBACK CONTROL CIRCUITRY

    EPA Science Inventory

    The paper give results of a characterization of ozone emissions from air cleaners equipped with ozone generators and sensor and feedback control circuitry. Ozone emission rates of several consumer appliances, marketed as indoor air treatment or air purification systems, were det...

  8. Development of a Clean Air Act Title V permit application for Argonne National Laboratory

    SciTech Connect

    Barrett, G.L.

    1994-06-01

    The Clean Air Act Amendments (CAAA) of 1990 instituted major changes in the way that air emission sources are regulated and permitted. Along with being a major research and development laboratory owned by the US Department of Energy, Argonne National Laboratory (ANL) is also classified as a major source of oxides of nitrogen (NO{sub x}) in the Chicago metropolitan area which has been designated by the US Environmental Protection Agency (USEPA) as severe (17) for ozone. As a major source ANL is therefore required under Title V of CAAA to apply for a federally enforceable permit for all sources of air emissions at the facility. While the ANL Boiler House represents the most significant emission source at the Laboratory, there are, nevertheless, a large number of other emission sources, some of which are currently permitted by the State of Illinois and others of which are exempt from state permitting requirements. A large number of R & D related sources are of relatively small magnitude. The ability to identify, inventory, characterize and classify all sources under the various titles of CAAA constitutes a major challenge for R & D laboratories of this size.

  9. Airborne lidar mapping of vertical ozone distributions in support of the 1990 Clean Air Act Amendments

    NASA Technical Reports Server (NTRS)

    Uthe, Edward E.; Nielsen, Norman B.; Livingston, John M.

    1992-01-01

    The 1990 Clean Air Act Amendments mandated attainment of the ozone standard established by the U.S. Environmental Protection Agency. Improved photochemical models validated by experimental data are needed to develop strategies for reducing near surface ozone concentrations downwind of urban and industrial centers. For more than 10 years, lidar has been used on large aircraft to provide unique information on ozone distributions in the atmosphere. However, compact airborne lidar systems are needed for operation on small aircraft of the type typically used on regional air quality investigations to collect data with which to develop and validate air quality models. Data presented in this paper will consist of a comparison between airborne differential absorption lidar (DIAL) and airborne in-situ ozone measurements. Also discussed are future plans to improve the airborne ultraviolet-DIAL for ozone and other gas observations and addition of a Fourier Transform Infrared (FTIR) emission spectrometer to investigate the effects of other gas species on vertical ozone distribution.

  10. Equipment

    NASA Astrophysics Data System (ADS)

    Szumski, Michał

    This chapter describes the most important features of capillary electrophoretic equipment. A presentation of the important developments in high voltage power supplies for chip CE is followed by preparation of fused silica capillaries for use in CE. Detection systems that are used in capillary electrophoresis are widely described. Here, UV-Vis absorbance measurements are discussed including different types of detection cells—also those less popular (u-shaped, Z-shaped, mirror-coated). Fluorescence detection and laser-induced fluorescence detection are the most sensitive detection systems. Several LIF setups, such as collinear, orthogonal, confocal, and sheath-flow cuvette, are presented from the point of view of the sensitivity they can provide. Several electrochemical detectors for CE, such as conductivity, amperometric, and potentiometric, are also shown and their constructions discussed. CE-MS and much less known CE (CEC)-NMR systems are also described. The examples of automation and robotized CE systems together with their potential fields of application are also presented.

  11. Competing Initiatives: A New Tobacco Industry Strategy to Oppose Statewide Clean Indoor Air Ballot Measures

    PubMed Central

    Tung, Gregory J.; Hendlin, Yogi H.

    2009-01-01

    To describe how the tobacco and gaming industries opposed clean indoor air voter initiatives in 2006, we analyzed media records and government and other publicly available documents and conducted interviews with knowledgeable individuals. In an attempt to avoid strict “smoke free” regulations pursued by health groups via voter initiatives in Arizona, Ohio, and Nevada, in 2006, the tobacco and gaming industries sponsored competing voter initiatives for alternative laws. Health groups succeeded in defeating the pro-tobacco competing initiatives because they were able to dispel confusion and create a head-to-head competition by associating each campaign with its respective backer and instructing voters to vote “no” on the pro-tobacco initiative in addition to voting “yes” on the health group initiative. PMID:19150904

  12. Implications of the Clean Air Act acid rain title on industrial boilers

    SciTech Connect

    Maibodi, M. )

    1991-11-01

    This paper discusses the impacts of the 1990 Clean Air Act Amendments related to acid rain controls, as they apply to industrial boilers. Emphasis is placed on explaining the Title IV provisions of the Amendments that permit nonutility sources to participate in the SO{sub 2} allowance system. The allowance system, as it pertains to industrial boiler operators, is described, and the opportunities for operators to trade and/or sell SO{sub 2} emission credits is discussed. The paper also reviews flue gas desulfurization system technologies available for industrial boiler operators who may choose to participate in the system. Furnace sorbent injection, advanced silicate process, lime spray drying, dry sorbent injection, and limestone scrubbing are described, including statements of their SO{sub 2} removing capability, commercial status, and costs. Capital costs, levelized costs and cost-effectiveness are presented for these technologies.

  13. Clean Air Act Title IV: Lessons learned from Phase I; getting ready for Phase II

    SciTech Connect

    Miller, M.J.

    1997-12-31

    The 1990 Clean Air Act Amendments have required significant reductions in SO{sub 2} and NO{sub x} emissions from fossil fuel-fired power plants in the US. This paper examines some of the key technical lessons learned in Phase I following retrofit of low NO{sub x} systems, FGD systems, and continuous emissions monitors. Some of the key problems encountered have been waterwall wastage as a result of low NO{sub x} burner retrofits; high LOI (carbon) ash as a result of low NO{sub x} operation; high O&M costs associated with CEMs; and the heat rate discrepancy which has arisen between CEMs and conventional heat rate calculations. As Phase II approaches, EPRI and the electric utility industry are investigating improvements in FGD systems (e.g., clear liquor scrubbing), advances in NO{sub x} control technologies, more robust CEM systems, and tools to help in the technology decision-making process.

  14. Escaping the regulatory dust bowl: fugitive dust and the Clean Air Act

    SciTech Connect

    Probst, G.L.; Becker, R.E. Jr.

    1982-01-01

    The Environmental Protection Agency's (EPA's) regulatory program, as it relates to particulates, is overly complicated. In attempting to accommodate statutory language insensitive to particulate differences, after becoming aware of the varying effects of different-sized particles, EPA has developed an unworkable program. Although agricultural, recreational, transportation, and industrial activities contribute to the airborne dust (or, in the Clean Air Act vernacular, fugitive dust), this article focuses on mining activities. Surface mining inevitably stirs up considerable fugitive dust, and a description of mining activities in arid conditions, and how they fit in with a developing regulatory program, reveals a story of a national program that fails to provide for rational policy and regional flexibility. The article also recommends some regulatory and statutory solutions that could relatively easily correct EPA's fugitive dust program.

  15. Development of an emergency air-cleaning system for liquid-metal reactors

    SciTech Connect

    Owen, R.K.

    1980-11-01

    A novel air cleaning concept has been developed for potential use in venting future commercial liquid metal fast breeder reactor containment buildings in the unlikely event of postulated core disruptive accidents. The passive concept consists of a submerged gravel bed to collect the bulk of particulate contaminates carried by the vented gas. A fibrous scrubber could be combined with the submerged gravel scrubber to enhance collection efficiencies for the smaller sized particles. The submerged gravel scrubber is unique in that water flow through the packed bed is induced by the gas flow, eliminating the need for an active liquid pump. In addition, design gas velocities through the packed bed are 10 to 20 times higher than for a conventional sand bed filter.

  16. Extended-life nuclear air cleaning filters via dynamic exclusion prefilters

    SciTech Connect

    Wright, S.R.; Crouch, H.S.; Bond, J.H.

    1997-08-01

    The primary objective of this investigation was to ascertain if a dynamic, self-cleaning particulate exclusion precleaner, designed for relatively large dust removal (2 to 100+ {mu}m diameter particles) from helicopter turbine inlets, could be extended to submicron filtration. The improved device could be used as a prefilter for HEPA filtration systems, significantly increasing service life. In nuclear air cleaning, its use would reduce the amount of nuclear particulate matter that would otherwise be entrapped in the HEPA filter cartridge/panel, causing fouling and increased back pressure, as well as requiring subsequent disposal of the contaminated media at considerable expense. A unique (patent-pending) mechanical separation device has recently been developed to extract particulate matter from fluid process streams based on a proprietary concept called Boundary Layer Momentum Transfer (BLMT). The device creates multiple boundary layers that actively exclude particles from entering the perimeter of the device, while allowing air to traverse the boundaries relatively unimpeded. A modified two-dimensional (2-D) computerized flow simulation model was used to assist in the prototype design. Empirical results are presented from particle breakthrough and AP experiments obtained from a reduced-scale prototype filter. Particles larger than 0.23 {mu}m were actively excluded by the prototype, but at a higher pressure drop than anticipated. Experimental data collected indicates that the filter housing and the inlet flow configuration may contribute significantly to improvements in device particle separation capabilities. Furthermore, preliminary experiments have shown that other downstream pressure drop considerations (besides those just across the spinning filtration disks) must be included to accurately portray the AP across the device. Further detailed quantitative investigations on a larger scale (1,000 CFM) prototype are warranted. 3 refs., 5 figs., 2 tabs.

  17. Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems.

    PubMed

    Macintosh, David L; Myatt, Theodore A; Ludwig, Jerry F; Baker, Brian J; Suh, Helen H; Spengler, John D

    2008-11-01

    A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates. PMID:19044163

  18. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9...

  19. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9...

  20. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, appendix A to... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber...

  1. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the...

  2. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the...

  3. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9...

  4. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of appendix A of...

  5. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, appendix A to... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber...

  6. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, appendix A to... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber...

  7. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the...

  8. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the...

  9. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, Appendix A to... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber...

  10. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9...

  11. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of appendix A of...

  12. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the...

  13. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, Appendix A to... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber...

  14. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9...

  15. S. 782: A bill to amend the Clean Air Act. Introduced in the Senate of the United States, One Hundredth First Congress, First Session, April 13, 1989

    SciTech Connect

    Not Available

    1989-01-01

    A bill was introduced in the Senate to amend the Clean Air Act by providing the Administrator of the Environmental Protection Agency with the authority to regulate air pollution on and over the Outer Continental Shelf.

  16. Measurement of air toxic emissions from a coal-fired boiler equipped with a tangentially-fired low NOx combustion system

    SciTech Connect

    Dismukes, E.B.; Clarkson, R.J.; Hardman, R.R.; Elia, G.G.

    1993-11-01

    This paper presents the results of measurements of chemical emissions from a coal-burning, tangentially-fired, utility boiler equipped with a hot-side electrostatic precipitator and a low NOx firing system. The tests were conducted in response to Title III of the 1990 Amendments to the Clean Air Act which lists 189 chemicals to be evaluated as {open_quotes}Air Toxics.{close_quotes} The project was jointly funded by the Electric Power Research Institute and the US Department of Energy under an existing Innovative Clean Coal Technology Cooperative Agreement managed by Southern Company Services. Field chemical emissions monitoring was conducted in two phases: a baseline {open_quotes}pre-low NOx burner{close_quotes} condition in September 1991 and in the LNCFS Level III low NOx firing condition in January 1992. In addition to stack emissions measurements of both organic and inorganic chemicals, plant material balance evaluations were performed to determine the efficiency of the hot-side ESP at controlling emissions of air toxics and to determine the fate of the target chemicals in various plant process streams.

  17. Accountability analysis of title IV phase 2 of the 1990 Clean Air Act Amendments.

    PubMed

    Morgenstern, Richard D; Harrington, Winston; Shih, Jhih-Shyang; Bell, Michelle L

    2012-11-01

    In this study, we sought to assess what portion, if any, of the reductions in ambient concentrations of particulate matter (PM*) < or = 2.5 microm in aerodynamic diameter (PM2.5) that occurred in the United States between the years 1999 and 2006 can be attributed to reductions in emissions of sulfur dioxide (SO2) and nitrogen oxides (NOx) resulting from implementation of Phase 2 of Title IV of the 1990 Clean Air Act Amendments. To this end, a detailed statistical model linking sources and monitors over time and space was used to estimate associations between the observed emissions reductions and improvements in air quality. Overall, it turned out to be quite feasible to use relatively transparent statistical methods to assess these outcomes of the Phase 2 program, which was designed to reduce long-range transport of emissions. Associations between changes in emissions from individual power plants and monitor-specific estimates of changes in concentrations of PM2.5, our indicator pollutant, were highly significant and were mostly of the expected relative magnitudes with respect to distances and directions from sources. Originally estimated on monthly data for a set of 193 monitors between 1999 and 2005, our preferred model performed equally well using data for the same 193 monitors for 2006 as well as for an additional 217 monitors not in the original set in 2006. Although substantial model uncertainty was observed, we were able to estimate that the Title IV Phase 2 emissions reduction program implemented between 1999 and 2005 reduced PM2.5 concentrations in the eastern United States by an average of 1.07 microg/m3 (standard deviation [SD] = 0.11 microg/m3) compared with a counterfactual case defined as there having been no change in emission rates per unit of energy input (1 million British thermal units [BTUs]). On a population-weighted basis, the comparable reduction in PM2.5 was 0.89 microg/m3. Compared with the air quality fate and transport models used by the

  18. In pursuit of clean air: a data book of problems and strategies at the state level. Supplement

    SciTech Connect

    Garvey, D.B.; Moser, S.B.; Streets, D.G.

    1980-08-01

    The Clean Air Act Amendments of 1977 and EPA regulations set stringent requirements for the control of emissions in areas where the National Ambient Air Quality Standards were being exceeded. This supplement updates a previous five-volume summary of nonattainment area designations and attainment strategies of the states as of July 1, 1980. It also contains maps of PSD Class I areas and additional information on coal production, coal reserves, and coal quality.

  19. Portable air pollution control equipment for the control of toxic particulate emissions

    SciTech Connect

    Chaurushia, A.; Odabashian, S.; Busch, E.

    1997-12-31

    Chromium VI (Cr VI) has been identified by the environmental regulatory agencies as a potent carcinogen among eleven heavy metals. A threshold level of 0.0001 lb/year for Cr VI emissions has been established by the California Air Resources Board for reporting under Assembly Bill 2588. A need for an innovative control technology to reduce fugitive emissions of Cr VI was identified during the Air Toxic Emissions Reduction Program at Northrop Grumman Military Aircraft Systems Division (NGMASD). NGMASD operates an aircraft assembly facility in El Segundo, CA. Nearly all of the aircraft components are coated with a protective coating (primer) prior to assembly. The primer has Cr VI as a component for its excellent corrosion resistance property. The complex assembly process requires fasteners which also need primer coating. Therefore, NGMASD utilizes High Volume Low Pressure (HVLP) guns for the touch-up spray coating operations. During the touch-up spray coating operations, Cr VI particles are atomized and transferred to the aircraft surface. The South Coast Air Quality Management District (SCAQMD) has determined that the HVLP gun transfers 65% of the paint particles onto the substrate and the remaining 35% are emitted as an overspray if air pollution controls are not applied. NGMASD has developed the Portable Air Pollution Control Equipment (PAPCE) to capture and control the overspray in order to reduce fugitive Cr VI emissions from the touch-up spray coating operations. A source test was performed per SCAQMD guidelines and the final report has been approved by the SCAQMD.

  20. High Mercury Wet Deposition at a "Clean Air" Site in Puerto Rico.

    PubMed

    Shanley, James B; Engle, Mark A; Scholl, Martha; Krabbenhoft, David P; Brunette, Robert; Olson, Mark L; Conroy, Mary E

    2015-10-20

    Atmospheric mercury deposition measurements are rare in tropical latitudes. Here we report on seven years (April 2005 to April 2012, with gaps) of wet Hg deposition measurements at a tropical wet forest in the Luquillo Mountains, northeastern Puerto Rico, U.S. Despite receiving unpolluted air off the Atlantic Ocean from northeasterly trade winds, during two complete years the site averaged 27.9 μg m(-2) yr(-1) wet Hg deposition, or about 30% more than Florida and the Gulf Coast, the highest deposition areas within the U.S. These high Hg deposition rates are driven in part by high rainfall, which averaged 2855 mm yr(-1). The volume-weighted mean Hg concentration was 9.8 ng L(-1), and was highest during summer and lowest during the winter dry season. Rainout of Hg (decreasing concentration with increasing rainfall depth) was minimal. The high Hg deposition was not supported by gaseous oxidized mercury (GOM) at ground level, which remained near global background concentrations (<10 pg m(-3)). Rather, a strong positive correlation between Hg concentrations and the maximum height of rain detected within clouds (echo tops) suggests that droplets in high convective cloud tops scavenge GOM from above the mixing layer. The high wet Hg deposition at this "clean air" site suggests that other tropical areas may be hotspots for Hg deposition as well.