  1. Measuring radon concentration in air using a diffusion cloud chamber

    NASA Astrophysics Data System (ADS)

    Cases, R.; Ros, E.; Zúñiga, J.

    2011-09-01

    Radon concentration in air is a major concern in lung cancer studies. A traditional technique used to measure radon abundance is the charcoal canister method. We propose a novel technique using a diffusion cloud chamber. This technique is simpler and can easily be used for physics demonstrations for high school and university students.

  2. Global Ammonia Concentrations Seen by the 13-years AIRS Measurements

    NASA Astrophysics Data System (ADS)

    Warner, Juying; Wei, Zigang; Larrabee Strow, L.; Dickerson, Russell; Nowak, John; Wang, Yuxuan

    2016-04-01

    Ammonia is an integral part of the nitrogen cycle and is projected to be the largest single contributor to each of acidification, eutrophication and secondary particulate matter in Europe by 2020 (Sutton et al., 2008). The impacts of NH3 also include: aerosol production affecting global radiative forcing, increases in emissions of the greenhouse gases nitrous oxide (N2O) and methane (CH4), and modification of the transport and deposition patterns of SO2 and NOx. Therefore, monitoring NH3 global distribution of sources is vitally important to human health with respect to both air and water quality and climate change. We have developed new daily and global ammonia (NH3) products from AIRS hyperspectral measurements. These products add value to AIRS's existing products that have made significant contributions to weather forecasts, climate studies, and air quality monitoring. With longer than 13 years of data records, these measurements have been used not only for daily monitoring purposes but also for inter-annual variability and short-term trend studies. We will discuss the global NH3 emission sources from biogenic and anthropogenic activities over many emission regions captured by AIRS. We will focus their variability in the last 13 years.

  3. LIF measurements of oxygen concentration gradients along flat and wavy air-water interfaces

    NASA Astrophysics Data System (ADS)

    Woodrow, Philip T., Jr.; Duke, Steve R.

    Instantaneous spatially-varying measurements of concentration gradients occurring during aeration for flat, stagnant air-water interfaces and for interfaces with mechanically-generated waves are presented. Measurements were obtained in a laboratory wave tank using a laser-induced fluorescence (LIF) technique that images planar oxygen concentration fields near air-water interfaces. Pulsed nitrogen laser light focused to a thin sheet induces the fluorescence of pyrene butyric acid (in micromolar concentration) in deoxygenated water. The PBA fluorescence is quenched by dissolved oxygen. A high-resolution CCD camera images in two dimensions the intensities of the fluorescence field, providing spatial measurements of oxygen concentration with magnification of 7 μm per pixel. The concentration fields, gradients, and boundary layer thicknesses along the flat and wavy air-water interfaces are quantified and compared to previous measurements associated with sheared gas-liquid interfaces and with wind-generated waves.

  4. Historical Occupational Trichloroethylene Air Concentrations Based on Inspection Measurements From Shanghai, China

    PubMed Central

    Friesen, Melissa C.; Locke, Sarah J.; Chen, Yu-Cheng; Coble, Joseph B.; Stewart, Patricia A.; Ji, Bu-Tian; Bassig, Bryan; Lu, Wei; Xue, Shouzheng; Chow, Wong-Ho; Lan, Qing; Purdue, Mark P.; Rothman, Nathaniel; Vermeulen, Roel

    2015-01-01

    Purpose: Trichloroethylene (TCE) is a carcinogen that has been linked to kidney cancer and possibly other cancer sites including non-Hodgkin lymphoma. Its use in China has increased since the early 1990s with China’s growing metal, electronic, and telecommunications industries. We examined historical occupational TCE air concentration patterns in a database of TCE inspection measurements collected in Shanghai, China to identify temporal trends and broad contrasts among occupations and industries. Methods: Using a database of 932 short-term, area TCE air inspection measurements collected in Shanghai worksites from 1968 through 2000 (median year 1986), we developed mixed-effects models to evaluate job-, industry-, and time-specific TCE air concentrations. Results: Models of TCE air concentrations from Shanghai work sites predicted that exposures decreased 5–10% per year between 1968 and 2000. Measurements collected near launderers and dry cleaners had the highest predicted geometric means (GM for 1986 = 150–190mg m−3). The majority (53%) of the measurements were collected in metal treatment jobs. In a model restricted to measurements in metal treatment jobs, predicted GMs for 1986 varied 35-fold across industries, from 11mg m−3 in ‘other metal products/repair’ industries to 390mg m–3 in ‘ships/aircrafts’ industries. Conclusions: TCE workplace air concentrations appeared to have dropped over time in Shanghai, China between 1968 and 2000. Understanding differences in TCE concentrations across time, occupations, and industries may assist future epidemiologic studies in China. PMID:25180291

  5. Laser induced fluorescence measurements of dissolved oxygen concentration fields near air bubble surfaces

    NASA Astrophysics Data System (ADS)

    Roy, Sabita; Duke, Steve R.

    2000-09-01

    This article describes a laser-induced fluorescence (LIF) technique for measuring dissolved oxygen concentration gradients in water near the surface of an air bubble. Air bubbles are created at the tip of a needle in a rectangular bubble column filled with water that contains pyrenebutyric acid (PBA). The fluorescence of the PBA is induced by a planar pulse of nitrogen laser light. Oxygen transferring from the air bubble to the deoxygenated water quenches the fluorescence of the PBA. Images of the instantaneous and two-dimensional fluorescence field are obtained by a UV-intensified charge-coupled device (CCD) camera. Quenching of fluorescence intensity is determined at each pixel in the CCD image to measure dissolved oxygen concentration. Two-dimensional concentration fields are presented for a series of measurements of oxygen transfer from 1.6 mm bubbles suspended on the tip of a needle in a quiescent fluid. The images show the spatially varying concentration profiles, gradients, and boundary layer thicknesses at positions around the bubble surfaces. These direct and local measurements of concentration behavior within the mass transfer boundary layer show the potential of this LIF technique for the development of general and mechanistic models for oxygen transport across the air-water interface.

  6. Performance of the Proposed New Federal Reference Methods for Measuring Ozone Concentrations in Ambient Air

    EPA Science Inventory

    The current Federal Reference Method (FRM) for measuring concentrations of ozone in ambient air, described in EPA regulations at 40 CFR Part 50, Appendix D, is based on the dry, gas-phase, chemiluminescence reaction between ethylene (C2H4) and any ozone (O

  7. Evaluation and Comparison of Chemiluminescence and UV Photometric Methods for Measuring Ozone Concentrations in Ambient Air

    EPA Science Inventory

    The current Federal Reference Method (FRM) for measuring concentrations of ozone in ambient air is based on the dry, gas-phase, chemiluminescence reaction between ethylene (C2H4) and any ozone (O3) that may be p...

  8. Ambient concentrations of aldehydes in relation to Beijing Olympic air pollution control measures

    NASA Astrophysics Data System (ADS)

    Gong, J. C.; Zhu, T.; Hu, M.; Zhang, L. W.; Cheng, H.; Zhang, L.; Tong, J.; Zhang, J.

    2010-08-01

    Aldehydes are ubiquitous constituents of the atmosphere. Their concentrations are elevated in polluted urban atmospheres. The present study was carried out to characterize three aldehydes of most health concern (formaldehyde, acetaldehyde, and acrolein) in a central Beijing site in the summer and early fall of 2008 (from June to October). Measurements were made before, during, and after the Beijing Olympics to examine whether the air pollution control measures implemented to improve Beijing's air quality during the Olympics had any impact on concentrations of the three aldehydes. Average concentrations of formaldehyde, acetaldehyde and acrolein were 29.34 ± 15.12 μg/m3, 27.09 ± 15.74 μg/m3 and 2.32 ± 0.95 μg/m3, respectively, for the entire period of measurements, all being the highest among the levels measured in cities around the world in photochemical smog seasons. Among the three measured aldehydes, only acetaldehyde had a substantially reduced mean concentration during the Olympic air pollution control period compared to the pre-Olympic period. Formaldehyde and acrolein followed the changing pattern of temperature and were each significantly correlated with ozone (a secondary product of photochemical reactions). In contrast, acetaldehyde was significantly correlated with several pollutants emitted mainly from local emission sources (e.g., NO2, CO, and PM2.5). These findings suggest that local direct emissions had a larger impact on acetaldehyde than formaldehyde and acrolein.

  9. Mixing layer height measurements determines influence of meteorology on air pollutant concentrations in urban area

    NASA Astrophysics Data System (ADS)

    Schäfer, Klaus; Blumenstock, Thomas; Bonn, Boris; Gerwig, Holger; Hase, Frank; Münkel, Christoph; Nothard, Rainer; von Schneidemesser, Erika

    2015-10-01

    Mixing layer height (MLH) is a key parameter to determine the influence of meteorological parameters upon air pollutants such as trace gas species and particulate concentrations near the surface. Meteorology, and MLH as a key parameter, affect the budget of emission source strengths, deposition, and accumulation. However, greater possibilities for the application of MLH data have been identified in recent years. Here, the results of measurements in Berlin in 2014 are shown and discussed. The concentrations of NO, NO2, O3, CO, PM1, PM2.5, PM10 and about 70 volatile organic compounds (anthropogenic and biogenic of origin) as well as particle size distributions and contributions of SOA and soot species to PM were measured at the urban background station of the Berlin air quality network (BLUME) in Nansenstr./Framstr., Berlin-Neukölln. A Vaisala ceilometer CL51, which is a commercial mini-lidar system, was applied at that site to detect the layers of the lower atmosphere in real time. Special software for these ceilometers with MATLAB provided routine retrievals of MLH from vertical profiles of laser backscatter data. Five portable Bruker EM27/SUN FTIR spectrometers were set up around Berlin to detect column averaged abundances of CO2 and CH4 by solar absorption spectrometry. Correlation analyses were used to show the coupling of temporal variations of trace gas compounds and PM with MLH. Significant influences of MLH upon NO, NO2, PM10, PM2.5, PM1 and toluene (marker for traffic emissions) concentrations as well as particle number concentrations in the size modes 70 - 100 nm, 100 - 200 nm and 200 - 500 nm on the basis of averaged diurnal courses were found. Further, MLH was taken as important auxiliary information about the development of the boundary layer during each day of observations, which was required for the proper estimation of CO2 and CH4 source strengths from Berlin on the basis of atmospheric column density measurements.

  10. Measurements of soot, OH, and PAH concentrations in turbulent ethylene/air jet flames

    SciTech Connect

    Lee, Seong-Young; Turns, Stephen R.; Santoro, Robert J.

    2009-12-15

    This paper presents results from an investigation of soot formation in turbulent, non-premixed, C{sub 2}H{sub 4}/air jet flames. Tests were conducted using a H{sub 2}-piloted burner with fuel issuing from a 2.18 mm i.d. tube into quiescent ambient air. A range of test conditions was studied using the initial jet velocity (16.2-94.1 m/s) as a parameter. Fuel-jet Reynolds numbers ranged from 4000 to 23,200. Planar laser-induced incandescence (LII) was employed to determine soot volume fractions, and laser-induced fluorescence (LIF) was used to measure relative hydroxyl radical (OH) concentrations and polycyclic aromatic hydrocarbons (PAHs) concentrations. Extensive information on the structure of the soot and OH fields was obtained from two-dimensional imaging experiments. Quantitative measurements were obtained by employing the LII and LIF techniques independently. Imaging results for soot, OH, and PAH show the existence of three soot formation/oxidation regions: a rapid soot growth region, in which OH and soot particles lie in distinctly different radial locations; a mixing-dominated region controlled by large-scale motion; and a soot-oxidation region in which the OH and soot fields overlap spatially, resulting in the rapid oxidation of soot particles. Detailed quantitative analyzes of soot volume fractions and OH and soot zone thicknesses were performed along with the temperature measurement using the N{sub 2}-CARS system. Measurements of OH and soot zone thicknesses show that the soot zone thickness increases linearly with axial distance in the soot formation region, whereas the OH zone thickness is nearly constant in this region. The OH zone thickness then rapidly increases with downstream distance and approximately doubles in the soot-oxidation region. Probability density functions also were obtained for soot volume fractions and OH concentrations. These probability density functions clearly define the spatial relationships among the OH, PAH concentrations, the

  11. Influence of precipitation on (7)Be concentrations in air as measured by CTBTO global monitoring system.

    PubMed

    Kusmierczyk-Michulec, J; Gheddou, A; Nikkinen, M

    2015-06-01

    Data collected by the International Monitoring System (IMS) during 2009-2012 were used to study influence of precipitation and relative humidity on changes in (7)Be concentrations in atmosphere. The significant decrease in (7)Be concentrations, corresponding to measurements collected by stations located within Intertropical Convergence Zone (ITCZ) is demonstrated. This effect can be attributed to the process of enhanced wet deposition within the ITCZ. To quantify this effect data collected by IMS stations within ITCZ were thoroughly analyzed. It was found that the atmospheric content of (7)Be strongly decreases under the rain conditions. The rain mediated depletion of (7)Be to half of its before rain value, needs about 62 h in case of light precipitation, while in the case of moderate precipitation about 38 h is needed. In addition the evaluated impact of humidity showed that increase in relative humidity by 20%, for example from 70% ± 5% to 90% ± 5% causes almost a double decrease in beryllium concentration in surface air.

  12. Uncertainty-weighted time averaging of mercury vapour concentrations in ambient air: application to measurements in the United kingdom.

    PubMed

    Brown, Richard J C; Muhunthan, Dharsheni

    2011-02-03

    Uncertainty-weighted time averaging of total gaseous mercury concentrations in ambient air, with associated robust uncertainties, has been performed for concentrations measured by the U.K. Heavy Metals Monitoring Network between 2007 and 2009. The results have been compared with averages produced using standard time-averaging methods with a view to investigating the properties of the new method and whether it represents an improvement over current practice.

  13. Indoor air quality in the Karns research houses: baseline measurements and impact of indoor environmental parameters on formaldehyde concentrations

    SciTech Connect

    Matthews, T. G.; Fung, K. W.; Tromberg, B. J.; Hawthorne, A. R.

    1985-12-01

    Baseline indoor air quality measurements, a nine-month radon study, and an environmental parameters study examining the impact of indoor temperature (T) and relative humidity (RH) levels on formaldehyde (CH2O) concentrations have been performed in three unoccupied research homes located in Karns, Tennessee. Inter-house comparison measurements of (1) CH2O concentration, (2) CH20 emission rates from primary CH20 emission sources, (3) radon and radon daughter concentrations, and (4) air exchange rates indicate that the three homes are similar. The results of the nine-month radon study indicate indoor concentrations consistently below the EPA recommended level of 4 pCi/L. Evidence was found that crawl-space concentrations may be reduced using heat pump systems whose outdoor units circulate fresh air through the crawl-spaoe. The modeled results of the environmental parameters study indicate approximate fourfold increases in CH20 concentrations from 0.07 to 0.27 ppm for seasonal T and RH conditions of 20°C, 30% RH and 29°C, 80% RH, respectively. Evaluation of these environmental parameters study data with steady-state CH2O concentration models developed from laboratory studies of the environmental dependence of CH2O emissions from particleboard underlayment indicate good correlations between the laboratory and field studies.

  14. A gravimetric approach to providing SI traceability for concentration measurement results of mercury vapor at ambient air levels

    NASA Astrophysics Data System (ADS)

    Ent, Hugo; van Andel, Inge; Heemskerk, Maurice; van Otterloo, Peter; Bavius, Wijnand; Baldan, Annarita; Horvat, Milena; Brown, Richard J. C.; Quétel, Christophe R.

    2014-11-01

    Current measurement and calibration capabilities for mercury vapor in air are maintained at levels of 0.2-40 μg Hg m-3. In this work, a mercury vapor generator has been developed to establish metrological traceability to the international system of units (SI) for mercury vapor measurement results ≤15 ng Hg m-3, i.e. closer to realistic ambient air concentrations (1-2 ng Hg m-3) [1]. Innovations developed included a modified type of diffusion cell, a new measurement method to weigh the loss in (mercury) mass of these diffusion cells during use (ca. 6-8 μg mass difference between successive weighings), and a new housing for the diffusion cells to maximize flow characteristics and to minimize temperature variations and adsorption effects. The newly developed mercury vapor generator system was tested by using diffusion cells generating 0.8 and 16 ng Hg min-1. The results also show that the filter system, to produce mercury free air, is working properly. Furthermore, and most importantly, the system is producing a flow with a stable mercury vapor content. Some additional improvements are still required to allow the developed mercury vapor generator to produce SI traceable mercury vapor concentrations, based upon gravimetry, at much lower concentration levels and reduced measurement uncertainties than have been achieved previously. The challenges to be met are especially related to developing more robust diffusion cells and better mass measurement conditions. The developed mercury vapor generator will contribute to more reliable measurement results of mercury vapor at ambient and background air levels, and also to better safety standards and cost reductions in industrial processes, such as the liquefied natural gas field, where aluminum main cryogenic heat exchangers are used which are particularly prone to corrosion caused by mercury.

  15. Amelioration of the reactive nitrogen flux calculation by a day/night separation in weekly mean air concentration measurements

    NASA Astrophysics Data System (ADS)

    Hayashi, Kentaro; Matsuda, Kazuhide; Ono, Keisuke; Tokida, Takeshi; Hasegawa, Toshihiro

    2013-11-01

    The low time resolution of air concentration data of atmospheric deposition in regional monitoring networks makes it difficult to estimate fluxes between the land and the atmosphere. The present study was an evaluation of the effects of day/night separation for a low time resolution of air concentration measurements (i.e., weekly mean) for the estimation of reactive nitrogen fluxes. The target chemical species included reactive nitrogen primarily ammonia (NH3) and nitric acid gas (HNO3) and secondarily nitrous acid gas, particulate ammonium, and particulate nitrate in addition to sulfur dioxide (SO2) as a reference. Monitoring was conducted for one year at a single-crop rice paddy field in central Japan. The study period was divided into the cropping and fallow seasons, which were characterized by rice plants or a drained bare soil surface, respectively. The filter-pack method was applied to measure the weekly mean air concentrations with day/night separation for the target species at two heights (6 and 2 m above the ground surface). Both an inferential and a gradient method were applied to calculate the deposition and exchange fluxes, respectively. The day/night separation in a weekly sampling protocol, on average, reduced the underestimation of HNO3 fluxes for the inferential method by 15.2% ± 6.8% and 8.2% ± 6.1% in the cropping and fallow seasons, respectively, and reduced the overestimation of NH3 fluxes for the gradient method by 121% ± 128% in the cropping season. The fluxes calculated using the inferential method agreed relatively well with those calculated using the gradient method for HNO3 and SO2. The use of single-height measurements for air concentrations with day/night separation and flux calculations using the inferential method are recommended as an appropriate way to enhance the quality in calculated fluxes while simultaneously suppress the increase in labor cost.

  16. ASSESSING THE COMPARABILITY OF AMMONIUM, NITRATE AND SULFATE CONCENTRATIONS MEASURED BY THREE AIR QUALITY MONITORING NETWORKS

    EPA Science Inventory

    Airborne fine particulate matter across the United States is monitored by different networks, the three prevalent ones presently being the Clean Air Status and Trend Network (CASTNet), the Interagency Monitoring of PROtected Visual Environment Network (IMPROVE) and the Speciati...

  17. Reducing indoor air formaldehyde concentrations

    SciTech Connect

    Meyer, B.; Hermanns, K.

    1985-08-01

    Urea-formaldehyde resin bonded particle board, medium density fiberboard and plywood paneling are used as flooring, wall paneling, for cabinet work and in furniture, and are present in almost every office, home and public building. If large quantities of these products are used in poorly ventilated spaces, high manufacturing quality control is necessary to avoid problems of latent formaldehyde release. Indoor air formaldehyde concentrations depend on the nature of the product, the product surface to air volume (loading) factor, temperature, humidity, age and product emission rates. Standard test methods are now available for measuring product emission rates that make it possible to predict the performance of UF-bonded pressed wood materials if use conditions and environmental parameters are known. Recent modifications in adhesive and board manufacturing parameters have made it possible to reduce formaldehyde emission significantly, and UF-bonded wood products are now capable of meeting indoor air quality standard levels of 0.1 ppm under almost all customary loading conditions.

  18. Source Term Estimates of Radioxenon Released from the BaTek Medical Isotope Production Facility Using External Measured Air Concentrations

    SciTech Connect

    Eslinger, Paul W.; Cameron, Ian M.; Dumais, Johannes R.; Imardjoko, Yudi; Marsoem, Pujadi; McIntyre, Justin I.; Miley, Harry S.; Stoehlker, Ulrich; Widodo, Susilo; Woods, Vincent T.

    2015-10-01

    Abstract Batan Teknologi (BaTek) operates an isotope production facility in Serpong, Indonesia that supplies 99mTc for use in medical procedures. Atmospheric releases of Xe-133 in the production process at BaTek are known to influence the measurements taken at the closest stations of the International Monitoring System (IMS). The purpose of the IMS is to detect evidence of nuclear explosions, including atmospheric releases of radionuclides. The xenon isotopes released from BaTek are the same as those produced in a nuclear explosion, but the isotopic ratios are different. Knowledge of the magnitude of releases from the isotope production facility helps inform analysts trying to decide whether a specific measurement result came from a nuclear explosion. A stack monitor deployed at BaTek in 2013 measured releases to the atmosphere for several isotopes. The facility operates on a weekly cycle, and the stack data for June 15-21, 2013 show a release of 1.84E13 Bq of Xe-133. Concentrations of Xe-133 in the air are available at the same time from a xenon sampler located 14 km from BaTek. An optimization process using atmospheric transport modeling and the sampler air concentrations produced a release estimate of 1.88E13 Bq. The same optimization process yielded a release estimate of 1.70E13 Bq for a different week in 2012. The stack release value and the two optimized estimates are all within 10 percent of each other. Weekly release estimates of 1.8E13 Bq and a 40 percent facility operation rate yields a rough annual release estimate of 3.7E13 Bq of Xe-133. This value is consistent with previously published estimates of annual releases for this facility, which are based on measurements at three IMS stations. These multiple lines of evidence cross-validate the stack release estimates and the release estimates from atmospheric samplers.

  19. Study on measurement of the coal powder concentration in pneumatic pipes of a boiler with relationship between air velocity and pressure drop

    SciTech Connect

    Pan, W.; Shen, F.; Lin, W.; Chen, L.; Zhang, D.; Wang, Q.; Ke, J.; Quan, W.

    1999-07-01

    According to the theoretical relationship between air velocity and pressure drop in different solid-air mass flow in vertical pipes with the condition of upward air-solid flowing, the experimental research on measuring the coal powder concentration is directed against the pneumatic pipes of a boiler's combustion system in the energy industry. Through analyzing the experimental results, a mathematical model for measuring the coal powder concentration in pneumatic pipes is obtained. Then, the error analysis is done, and the method of on-line measurement and its function are provided.

  20. The Application of Laser Diagnostics to the Measurement of Concentration and Temperature in Practical Methane-Air Flames

    NASA Astrophysics Data System (ADS)

    Nguyen, Quang-Viet

    1995-01-01

    The majority of natural gas, composed primarily of methane (CH_4), is consumed by practical devices that include Bunsen burners (used for industrial process and residential heating), and lean-premixed combustors (used for utility power generation and gas turbines). The goal of designing energy efficient, low-pollution burners and combustors is often most effectively realized through the use of numerical codes that model these devices. The accurate numerical modeling of these practical combustion devices frequently requires the non-intrusive measurements of various species and temperatures in flames for comparison and validation. The measurement of the pollutants carbon monoxide (CO) and nitric oxide (NO), however, is at the forefront of interest due to their nature as regulated pollutants. Thus, the concentration and temperature of various molecules (indicated in parenthesis) as they exist in Bunsen flames and lean-premixed combustors burning mixtures of CH_4 and air, were measured using the following non-intrusive techniques: line-of-sight, diode laser absorption (CO), laser Raman and Rayleigh scattering (CO, H_2, CO_2, H_2O, O_2, N_2, CH_4, and laser induced fluorescence (NO, OH, CO). The different diagnostic techniques each have their advantages and disadvantages. The absorption techniques were versatile at measuring both low- and high-level concentrations of CO, and when used in conjunction with computer tomographic reconstruction techniques, they also provide spatially resolved measurements. Raman and Rayleigh scattering proved to be perhaps the most powerful techniques due to their ability to simultaneously measure a wealth of different molecules and to provide an extremely accurate measurement of temperature while providing excellent temporal and spatial resolution. Raman scattering, however, is a weak process, thus the detection of anything much less than a percent mole fraction at flame temperatures is difficult. For species which require a higher degree

  1. Comparing three vegetation monoterpene emission models to measured gas concentrations with a model of meteorology, air chemistry and chemical transport

    NASA Astrophysics Data System (ADS)

    Smolander, S.; He, Q.; Mogensen, D.; Zhou, L.; Bäck, J.; Ruuskanen, T.; Noe, S.; Guenther, A.; Aaltonen, H.; Kulmala, M.; Boy, M.

    2014-10-01

    Biogenic volatile organic compounds (BVOCs) are essential in atmospheric chemistry because of their chemical reactions that produce and destroy tropospheric ozone, their effects on aerosol formation and growth, and their potential influence on global warming. As one of the important BVOC groups, monoterpenes have been a focus of scientific attention in atmospheric research. Detailed regional measurements and model estimates are needed to study emission potential and the monoterpene budget on a global scale. Since the use of empirical measurements for upscaling is limited by many physical and biological factors, such as genetic variation, temperature and light, water availability, seasonal changes, and environmental stresses, comprehensive inventories over larger areas are difficult to obtain. We applied the boundary-layer-chemistry-transport model SOSA (model to Simulate the concentrations of Organic vapours and Sulphuric Acid) to investigate Scots pine (Pinus sylvestris) monoterpene emissions in a boreal coniferous forest at the SMEAR (Station for Measuring forest Ecosystem-Atmosphere Relations) II site, southern Finland. SOSA was applied to simulate monoterpene emissions with three different emission modules: the semiempirical G95, MEGAN (Model of Emissions of Gases and Aerosols from Nature) 2.04 with improved descriptions of temperature and light responses and including also carbonyl emissions, and a process-based model SIM-BIM (Seasonal Isoprenoid synthase Model - Biochemical Isoprenoid biosynthesis Model). For the first time, the emission models included seasonal and diurnal variations in both quantity and chemical species of emitted monoterpenes, based on parameterizations obtained from field measurements. Results indicate that modelling and observations agreed reasonably well and that the model can be used for investigating regional air chemistry questions related to monoterpenes. The predominant modelled monoterpene concentrations, α-pinene and Δ3-carene

  2. Comparing three vegetation monoterpene emission models to measured gas concentrations with a model of meteorology, air chemistry and chemical transport

    NASA Astrophysics Data System (ADS)

    Smolander, S.; He, Q.; Mogensen, D.; Zhou, L.; Bäck, J.; Ruuskanen, T.; Noe, S.; Guenther, A.; Aaltonen, H.; Kulmala, M.; Boy, M.

    2013-11-01

    Biogenic volatile organic compounds (BVOCs) are essential in atmospheric chemistry because of their chemical reactions that produce and destroy tropospheric ozone, their effects on aerosol formation and growth, and their potential influence on global warming. As one of the important BVOC groups, monoterpenes have been a focus of scientific attention in atmospheric research. Detailed regional measurements and model estimates are needed to study emission potential and the monoterpene budget on a global scale. Since the use of empirical measurements for upscaling is limited by many physical and biological factors such as genetic variation, temperature and light, water availability, seasonal changes, and environmental stresses, comprehensive inventories over larger areas are difficult to obtain. We applied the boundary layer-chemistry-transport model SOSA to investigate Scots pine (Pinus sylvestris) monoterpene emissions in a boreal coniferous forest at the SMEAR II site, Southern Finland. SOSA was applied to simulate monoterpene emissions with three different emission modules: the semi-empirical G95, MEGAN 2.04 with improved descriptions of temperature and light responses and including also carbonyl emissions, and a process-based model SIM-BIM. For the first time, the emission models included seasonal and diurnal variations in both quantity and chemical species of emitted monoterpenes, based on parameterizations obtained from field measurements. Results indicate that modelling and observations agreed reasonably well, and that the model can be used for investigating regional air chemistry questions related to monoterpenes. The predominant modelled monoterpene concentrations, α-pinene and Δ3-carene, are consistent with observations.

  3. Observations on using inside air concentrations as a predictor of outside air concentrations

    SciTech Connect

    Hawkley, Gavin; Whicker, Jeffrey; Harris, Jason

    2015-04-01

    Here, excavations of radiological material were performed within confined structures with known operational parameters, such as a filtered exhaust system with known filtration efficiency. Given the known efficiency, the assumption could be made that the air concentrations of radioactivity measured outside the structure would be proportional to the air concentrations measured inside the structure. To investigate this assumption, the inside concentration data was compared with the outside concentration data. The correlation of the data suggested that the inside concentrations were not a good predictor of the outside concentrations. This poor correlation was deemed to be a result of operational unknowns within the structures.

  4. Observations on using inside air concentrations as a predictor of outside air concentrations

    DOE PAGES

    Hawkley, Gavin; Whicker, Jeffrey; Harris, Jason

    2015-04-01

    Here, excavations of radiological material were performed within confined structures with known operational parameters, such as a filtered exhaust system with known filtration efficiency. Given the known efficiency, the assumption could be made that the air concentrations of radioactivity measured outside the structure would be proportional to the air concentrations measured inside the structure. To investigate this assumption, the inside concentration data was compared with the outside concentration data. The correlation of the data suggested that the inside concentrations were not a good predictor of the outside concentrations. This poor correlation was deemed to be a result of operational unknownsmore » within the structures.« less

  5. Tuneable Diode Laser for measuring CO2 and CO air concentration on New Zealand volcanoes: An emerging technique

    NASA Astrophysics Data System (ADS)

    Mazot, A.; Christenson, B. W.

    2012-12-01

    A new technique, called Open-Path laser, has been used for monitoring of CO2 degassing in volcanic areas in New Zealand. The purpose of these surveys is to have a better knowledge in the spatial and temporal dynamics of CO2 degassing in the atmosphere. CO2 is less reactive than other volcanic gases. CO is present in lesser amounts in volcanic gases but the CO/CO2 ratio is a good indicator of the redox conditions at depth because a change in the ratio can be related to a new input of magma in the volcanic system. This presentation introduces the new laser based technique for future volcanic gas surveillance at Ruapehu volcano, New Zealand. Frequent mild to moderate explosive eruptions have occurred in historical time from the crater lake of Ruapehu with the last hydrothermal eruption occurring in September 2007. The pH of the lake is around 1.1 with lake temperatures ranging from 10 to 60 oC. CO2 emission measurements have been made since 2003 from an airborne platform at a constant distance from the summit and the data were processed using the plume contouring method. The total CO2 emission rate varies from not detectable to 2200 t/day. We here show new results from a measurement campaign conduced 23 May, 2012 over the Ruapehu Crater lake and show how paths are reduced to CO2 values. The values are then compared to long term measurements obtained on the airborne platform. This technique has been also used on another New Zealand volcano, Tongariro which showed volcano seismic unrest beginning in mid-July 2012. The last eruption at the Tongariro volcano was from Te Maari craters in 1897 with reported ash fall as far as Napier 115 km away from the volcano. In response to this activity, we conducted a range of geochemical sampling including, spring sampling and soil gas measurements. In addition, we tested the Tuneable Diode Laser to measure CO2 air concentration. The new method may prove useful for geochemical gas surveillance in combination with the geodetic and

  6. Air Pollution and Preterm Birth in the U.S. State of Georgia (2002–2006): Associations with Concentrations of 11 Ambient Air Pollutants Estimated by Combining Community Multiscale Air Quality Model (CMAQ) Simulations with Stationary Monitor Measurements

    PubMed Central

    Hao, Hua; Chang, Howard H.; Holmes, Heather A.; Mulholland, James A.; Klein, Mitch; Darrow, Lyndsey A.; Strickland, Matthew J.

    2015-01-01

    Background: Previous epidemiologic studies suggest associations between preterm birth and ambient air pollution. Objective: We investigated associations between 11 ambient air pollutants, estimated by combining Community Multiscale Air Quality model (CMAQ) simulations with measurements from stationary monitors, and risk of preterm birth (< 37 weeks of gestation) in the U.S. state of Georgia. Methods: Birth records for singleton births ≥ 27 weeks of gestation with complete covariate information and estimated dates of conception between 1 January 2002 and 28 February 2006 were obtained from the Office of Health Indicators for Planning, Georgia Department of Public Health (n = 511,658 births). Daily pollutant concentrations at 12-km resolution were estimated for 11 ambient air pollutants. We used logistic regression with county-level fixed effects to estimate associations between preterm birth and average pollutant concentrations during the first and second trimester. Discrete-time survival models were used to estimate third-trimester and total pregnancy associations. Effect modification was investigated by maternal education, race, census tract poverty level, and county-level urbanicity. Results: Trimester-specific and total pregnancy associations (p < 0.05) were observed for several pollutants. All the traffic-related pollutants (carbon monoxide, nitrogen dioxide, PM2.5 elemental carbon) were associated with preterm birth [e.g., odds ratios for interquartile range increases in carbon monoxide during the first, second, and third trimesters and total pregnancy were 1.005 (95% CI: 1.001, 1.009), 1.007 (95% CI: 1.002, 1.011), 1.010 (95% CI: 1.006, 1.014), and 1.011 (95% CI: 1.006, 1.017)]. Associations tended to be higher for mothers with low educational attainment and African American mothers. Conclusion: Several ambient air pollutants were associated with preterm birth; associations were observed in all exposure windows. Citation: Hao H, Chang HH, Holmes HA

  7. Scavenging ratios based on inflow air concentrations

    SciTech Connect

    Davis, W.E.; Dana, M.T.; Lee, R.N.; Slinn, W.G.N.; Thorp, J.M.

    1991-07-01

    Scavenging ratios were calculated from field measurements made during April 1985. Event precipitation samples were collected at the surface, but air chemistry measurements in the air mass feeding the precipitation were made from an aircraft. In contrast, ratios calculated in previous studies have used air concentration and precipitation chemistry data from only surface measurements. Average scavenging ratios were calculated for SO{sub 4}{sup 2{minus}}, NO{sub 3}{sup {minus}}, NH{sub 4}{sup +}, total sulfate, total nitrate, and total ammonium for 5 events; the geometric mean of these scavenging ratios were 8.5 {times} 10{sup 5}, 5.6 {times} 10{sup 6}, 4.3 {times} 10{sup 5}, 3.4 {times} 10{sup 5}, 2.4 {times} 10{sup 6}, and 9.7 {times} 10{sup 4}, respectively. These means are similar to but less variable than previous ratios formed using only surface data.

  8. Initial measurements of CO2 concentrations (1530 to 1940 AD) in air occluded in the GISP 2 Ice Core from central Greenland

    NASA Astrophysics Data System (ADS)

    Wahlen, M.; Allen, D.; Deck, B.; Herchenroder, A.

    Initial measurements of CO2 in the air of bubbles in the GISP 2 (Greenland Ice Sheet Project 2) ice core were performed using a dry extraction technique and tunable diode laser absorption spectroscopy. The record spans the years 1530 to 1940, and includes part of the little ice age. Absolute dating of the air was obtained from the location of the 14CO2 bomb peak in the bubble air, relative dating from the seasonal variations of H218O and electro-conductivity. The results for preindustrial times indicate constant atmospheric CO2 levels of 280±5 ppmv between 1530 and 1810 AD. Thereafter the concentrations rise rather abruptly. The record smoothly connects to the direct atmospheric observations from Mauna Loa.

  9. Estimates of radioxenon released from Southern Hemisphere medical isotope production facilities using measured air concentrations and atmospheric transport modeling.

    PubMed

    Eslinger, Paul W; Friese, Judah I; Lowrey, Justin D; McIntyre, Justin I; Miley, Harry S; Schrom, Brian T

    2014-09-01

    The International Monitoring System (IMS) of the Comprehensive-Nuclear-Test-Ban-Treaty monitors the atmosphere for radioactive xenon leaking from underground nuclear explosions. Emissions from medical isotope production represent a challenging background signal when determining whether measured radioxenon in the atmosphere is associated with a nuclear explosion prohibited by the treaty. The Australian Nuclear Science and Technology Organisation (ANSTO) operates a reactor and medical isotope production facility in Lucas Heights, Australia. This study uses two years of release data from the ANSTO medical isotope production facility and (133)Xe data from three IMS sampling locations to estimate the annual releases of (133)Xe from medical isotope production facilities in Argentina, South Africa, and Indonesia. Atmospheric dilution factors derived from a global atmospheric transport model were used in an optimization scheme to estimate annual release values by facility. The annual releases of about 6.8 × 10(14) Bq from the ANSTO medical isotope production facility are in good agreement with the sampled concentrations at these three IMS sampling locations. Annual release estimates for the facility in South Africa vary from 2.2 × 10(16) to 2.4 × 10(16) Bq, estimates for the facility in Indonesia vary from 9.2 × 10(13) to 3.7 × 10(14) Bq and estimates for the facility in Argentina range from 4.5 × 10(12) to 9.5 × 10(12) Bq. PMID:24811887

  10. Estimates of Radioxenon Released from Southern Hemisphere Medical isotope Production Facilities Using Measured Air Concentrations and Atmospheric Transport Modeling

    SciTech Connect

    Eslinger, Paul W.; Friese, Judah I.; Lowrey, Justin D.; McIntyre, Justin I.; Miley, Harry S.; Schrom, Brian T.

    2014-09-01

    Abstract The International Monitoring System (IMS) of the Comprehensive-Nuclear-Test-Ban-Treaty monitors the atmosphere for radioactive xenon leaking from underground nuclear explosions. Emissions from medical isotope production represent a challenging background signal when determining whether measured radioxenon in the atmosphere is associated with a nuclear explosion prohibited by the treaty. The Australian Nuclear Science and Technology Organisation (ANSTO) operates a reactor and medical isotope production facility in Lucas Heights, Australia. This study uses two years of release data from the ANSTO medical isotope production facility and Xe-133 data from three IMS sampling locations to estimate the annual releases of Xe-133 from medical isotope production facilities in Argentina, South Africa, and Indonesia. Atmospheric dilution factors derived from a global atmospheric transport model were used in an optimization scheme to estimate annual release values by facility. The annual releases of about 6.8×1014 Bq from the ANSTO medical isotope production facility are in good agreement with the sampled concentrations at these three IMS sampling locations. Annual release estimates for the facility in South Africa vary from 1.2×1016 to 2.5×1016 Bq and estimates for the facility in Indonesia vary from 6.1×1013 to 3.6×1014 Bq. Although some releases from the facility in Argentina may reach these IMS sampling locations, the solution to the objective function is insensitive to the magnitude of those releases.

  11. Source term estimation using air concentration measurements and a Lagrangian dispersion model - Experiments with pseudo and real cesium-137 observations from the Fukushima nuclear accident

    NASA Astrophysics Data System (ADS)

    Chai, Tianfeng; Draxler, Roland; Stein, Ariel

    2015-04-01

    A transfer coefficient matrix (TCM) was created in a previous study using a Lagrangian dispersion model to provide plume predictions under different emission scenarios. The TCM estimates the contribution of each emission period to all sampling locations and can be used to estimate source terms by adjusting emission rates to match the model prediction with the measurements. In this paper, the TCM is used to formulate a cost functional that measures the differences between the model predictions and the actual air concentration measurements. The cost functional also includes a background term which adds the differences between a first guess and the updated emission estimates. Uncertainties of the measurements, as well as those for the first guess of source terms are both considered in the cost functional. In addition, a penalty term is added to create a smooth temporal change in the release rate. The method is first tested with pseudo observations generated using the Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) model at the same location and time as the actual observations. The inverse estimation system is able to accurately recover the release rates and performs better than a direct solution using singular value decomposition (SVD). It is found that computing ln(c) differences between model and observations is better than using the original concentration c differences in the cost functional. The inverse estimation results are not sensitive to artificially introduced observational errors or different first guesses. To further test the method, daily average cesium-137 air concentration measurements around the globe from the Fukushima nuclear accident are used to estimate the release of the radionuclide. Compared with the latest estimates by Katata et al. (2014), the recovered release rates successfully capture the main temporal variations. When using subsets of the measured data, the inverse estimation method still manages to identify most of the

  12. INDOOR AIR CONCENTRATION UNIT CONVERSIONS

    EPA Science Inventory

    Migration of volatile chemicals from the subsurface into overlying buildings is called vapor intrusion (VI). Volatile organic chemicals in contaminated soils or groundwater can emit vapors, which can migrate through subsurface soils and may enter the indoor air of overlying buil...

  13. Direct AFM force measurements between air bubbles in aqueous polydisperse sodium poly(styrene sulfonate) solutions: effect of collision speed, polyelectrolyte concentration and molar mass.

    PubMed

    Browne, Christine; Tabor, Rico F; Grieser, Franz; Dagastine, Raymond R

    2015-07-01

    Interactions between colliding air bubbles in aqueous solutions of polydisperse sodium poly(styrene sulfonate) (NaPSS) using direct force measurements were studied. The forces measured with deformable interfaces were shown to be more sensitive to the presence of the polyelectrolytes when compared to similar measurements using rigid interfaces. The experimental factors that were examined were NaPSS concentration, bubble collision velocity and polyelectrolyte molar mass. These measurements were then compared with an analytical model based on polyelectrolyte scaling theory in order to explain the effects of concentration and bubble deformation on the interaction between bubbles. Typically structural forces from the presence of monodisperse polyelectrolyte between interacting surfaces may be expected, however, it was found that the polydispersity in molar mass resulted in the structural forces to be smoothed and only a depletion interaction was able to be measured between interacting bubbles. It was found that an increase in number density of NaPSS molecules resulted in an increase in the magnitude of the depletion interaction. Conversely this interaction was overwhelmed by an increase in the fluid flow in the system at higher bubble collision velocities. Polymer molar mass dispersity plays a significant role in the interactions present between the bubbles and has implications that also affect the polyelectrolyte overlap concentration of the solution. Further understanding of these implications can be expected to play a role in the improvement in operations in such fields as water treatment and mineral processing where polyelectrolytes are used extensively.

  14. Remote air pollution measurement

    NASA Technical Reports Server (NTRS)

    Byer, R. L.

    1975-01-01

    This paper presents a discussion and comparison of the Raman method, the resonance and fluorescence backscatter method, long path absorption methods and the differential absorption method for remote air pollution measurement. A comparison of the above remote detection methods shows that the absorption methods offer the most sensitivity at the least required transmitted energy. Topographical absorption provides the advantage of a single ended measurement, and differential absorption offers the additional advantage of a fully depth resolved absorption measurement. Recent experimental results confirming the range and sensitivity of the methods are presented.

  15. OPERATIONAL LIMITATIONS FOR DEMOLITION OF A HIGHLY ALPHA CONTAMINATED BUILDING MODLES VERSUS MEASURED AIR & SURFACE ACTIVITY CONCENTRATIONS

    SciTech Connect

    LLOYD, E.R.

    2006-11-02

    The demolition of a facility historically used for processing and handling transuranic materials is considered. Residual alpha emitting radionuclide contamination poses an exposure hazard if released to the local environment during the demolition. The process of planning for the demolition of this highly alpha contaminated building, 232-Z, included a predemolition modeling analysis of potential exposures. Estimated emission rates were used as input to an air dispersion model to estimate frequencies of occurrence of peak air and surface exposures. Postdemolition modeling was also conducted, based on the actual demolition schedule and conditions. The modeling results indicated that downwind deposition is the main operational limitation for demolition of a highly alpha-contaminated building. During the demolition of 232-Z, airborne radiation and surface contamination were monitored. The resultant non-detect monitoring results indicate a significant level of conservatism in the modeled results. This comparison supports the use of more realistic assumption in the estimating emission rates. The resultant reduction in modeled levels of potential exposures has significant implications in terms of the projected costs of demolition of such structures.

  16. Measurement of black carbon concentration as an indicator of air quality benefits of traffic restriction policies within the ecopass zone in Milan, Italy

    NASA Astrophysics Data System (ADS)

    Invernizzi, Giovanni; Ruprecht, Ario; Mazza, Roberto; De Marco, Cinzia; Močnik, Griša; Sioutas, Costantinos; Westerdahl, Dane

    2011-07-01

    Traffic restrictions are an unpopular tool to mitigate urban air pollution, and a measurable improvement in air quality is needed to demonstrate the effectiveness of this measure. Previous attempts failed to detect measurable reductions of PM mass pollution within the areas subject to traffic restriction. However black carbon, which is emitted primarily by traffic sources, could be a PM metric more suitable than PM mass to demonstrate pollutant reductions. In this study we report the results of a black carbon monitoring campaign carried out in Milan, Italy, with the aim to detect - and demonstrate more suitably than PM mass - differences in local urban air quality among three zones located very closely with different traffic intensity. The study was carried out in three different days by measuring simultaneously black carbon and PM mass concentrations with fixed monitoring stations located in three main radial roads connecting the outskirts to the city center, each with three segments: 1) an outer one, with no traffic restrictions 2) an intermediate one, subject to the congestion traffic charge called "Ecopass", where a ticket is required to enter for cars equipped with engines prior to Euro 4 standard; 3) the pedestrian zone (no cars admitted) of Duomo Square in the city center, where each of the three main roads ends. The results demonstrated a sharply declining gradient in black carbon levels from the outer zone, without traffic restrictions, to the more central areas, for all of the three radial main roads. The differences in mean black carbon levels in the same day in the different traffic scheme locations were highly significant for each comparison. In contrast to the Black carbon results, mean PM 10, PM 2.5, PM 1 concentrations did not show significant differences among the different traffic zones on the different campaign days. The ratio of black carbon to PM 10 decreased by 47% and 62% in the Ecopass zone and in the pedestrian zone, respectively, as

  17. Simultaneous measurement of 2-dimensional H2O concentration and temperature distribution in premixed methane/air flame using TDLAS-based tomography technology

    NASA Astrophysics Data System (ADS)

    Wang, Fei; Wu, Qi; Huang, Qunxing; Zhang, Haidan; Yan, Jianhua; Cen, Kefa

    2015-07-01

    An innovative tomographic method using tunable diode laser absorption spectroscopy (TDLAS) and algebraic reconstruction technique (ART) is presented in this paper for detecting two-dimensional distribution of H2O concentration and temperature in a premixed flame. The collimated laser beam emitted from a low cost diode laser module was delicately split into 24 sub-beams passing through the flame from different angles and the acquired laser absorption signals were used to retrieve flame temperature and H2O concentration simultaneously. The efficiency of the proposed reconstruction system and the effect of measurement noise were numerically evaluated. The temperature and H2O concentration in flat methane/air premixed flames under three different equivalence ratios were experimentally measured and reconstruction results were compared with model calculations. Numerical assessments indicate that the TDLAS tomographic system is capable for temperature and H2O concentration profiles detecting even the noise strength reaches 3% of absorption signal. Experimental results under different combustion conditions are well demonstrated along the vertical direction and the distribution profiles are in good agreement with model calculation. The proposed method exhibits great potential for 2-D or 3-D combustion diagnostics including non-uniform flames.

  18. Comparing three vegetation monoterpene emission models to measured gas concentrations with a model of meteorology, air chemistry and chemical transport

    SciTech Connect

    Smolander, S.; He, Q.; Mogensen, Ditte; Zhou, L.; Back, J.; Ruuskanen, T.; Noe, S.; Guenther, Alex B.; Aaltonen, H.; Kulmala, M.; Boy, Michael

    2014-10-07

    Biogenic volatile organic compounds (BVOCs) are essential in atmospheric chemistry because of their chemical reactions that produce and destroy tropospheric ozone, their effects on aerosol formation and growth, and their potential influence on global warming. As one of the important BVOC groups, monoterpenes have been a focus of scientific attention in atmospheric research. Detailed regional measurements and model estimates are needed to study emission potential and the monoterpene budget on a global scale. Since the use of empirical measurements for upscaling is limited by many physical and biological factors such as genetic variation, temperature and light, water availability, seasonal changes, and environmental stresses, comprehensive inventories over larger areas are difficult to obtain.

  19. A study on the atmospheric concentrations of primary and secondary air pollutants in the Athens basin performed by DOAS and DIAL measuring techniques.

    PubMed

    Kalabokas, P D; Papayannis, A D; Tsaknakis, G; Ziomas, I

    2012-01-01

    In this work an analysis of continuous Differential Optical Absorption Spectroscopy (DOAS) measurements of primary and secondary air pollutants (SO(2), NO(2) and O(3)) in the Athens basin is performed combined with Differential Absorption Lidar (DIAL) vertical ozone measurements obtained inside the Planetary Boundary Layer (PBL) and the lower free troposphere. The measurements took place during the period May 2005-February 2007, at the National Technical University of Athens Campus (200 m above sea level (asl.), 37.96 °N, 23.78 °E). The SO(2) and NO(2) DOAS measurements showed maximum 1-hour mean values (around 20 μg/m(3) and 74 μg/m(3), respectively) in winter and did not exceed the current European Union (EU) air quality standards (European Council Directive 2008/50/EC), in contrast to ozone, which shows its maximum (around 128 μg/m(3)) in summer and frequently exceeds the EU standard for human health protection (120 μg/m(3)). If the measurements are classified according to the two most frequent flow-patterns of the air masses in the Athens basin (northern-southern circulation), it is observed that in general the atmospheric concentrations of all measured pollutants including ozone are higher when the southern circulation occurs, in comparison to the corresponding values under the northern circulation. The vertical ozone profiles obtained by DIAL were also higher under the southern circulation. During the summer months a mean difference (between the southern-northern circulations) of the order of 15-20 μg/m(3), maximized at the 0.9-1.1 km and 1.7-1.8 km height, was observed within the PBL. It was also observed that the summer surface ozone levels remained relatively high (around 80-110 μg/m(3)) even during strong northerly winds, verifying the high levels of rural surface ozone in the surrounding area reported by previous studies. PMID:22153607

  20. A study on the atmospheric concentrations of primary and secondary air pollutants in the Athens basin performed by DOAS and DIAL measuring techniques.

    PubMed

    Kalabokas, P D; Papayannis, A D; Tsaknakis, G; Ziomas, I

    2012-01-01

    In this work an analysis of continuous Differential Optical Absorption Spectroscopy (DOAS) measurements of primary and secondary air pollutants (SO(2), NO(2) and O(3)) in the Athens basin is performed combined with Differential Absorption Lidar (DIAL) vertical ozone measurements obtained inside the Planetary Boundary Layer (PBL) and the lower free troposphere. The measurements took place during the period May 2005-February 2007, at the National Technical University of Athens Campus (200 m above sea level (asl.), 37.96 °N, 23.78 °E). The SO(2) and NO(2) DOAS measurements showed maximum 1-hour mean values (around 20 μg/m(3) and 74 μg/m(3), respectively) in winter and did not exceed the current European Union (EU) air quality standards (European Council Directive 2008/50/EC), in contrast to ozone, which shows its maximum (around 128 μg/m(3)) in summer and frequently exceeds the EU standard for human health protection (120 μg/m(3)). If the measurements are classified according to the two most frequent flow-patterns of the air masses in the Athens basin (northern-southern circulation), it is observed that in general the atmospheric concentrations of all measured pollutants including ozone are higher when the southern circulation occurs, in comparison to the corresponding values under the northern circulation. The vertical ozone profiles obtained by DIAL were also higher under the southern circulation. During the summer months a mean difference (between the southern-northern circulations) of the order of 15-20 μg/m(3), maximized at the 0.9-1.1 km and 1.7-1.8 km height, was observed within the PBL. It was also observed that the summer surface ozone levels remained relatively high (around 80-110 μg/m(3)) even during strong northerly winds, verifying the high levels of rural surface ozone in the surrounding area reported by previous studies.

  1. Daily variations of indoor air-ion and radon concentrations.

    PubMed

    Kolarz, P M; Filipović, D M; Marinković, B P

    2009-11-01

    Air-ions and radon are two atmospheric trace constituents which have two opposite effects on human health: the ions are beneficial, and radon gas is potentially lethal as it increases the risk of lung cancer. In the lower troposphere, radon is the most important generator of the air-ions. Ionization by cosmic rays and radioactive minerals is almost constant in daily cycles, and variation of air-ion concentrations is attributed to changes of the radon activity. Air-ion and radon concentrations in outdoor and indoor space and their vertical gradients in residential buildings were measured. Gerdien type air-ion detector "CDI-06" made in our laboratory and radon monitor "RAD7" were utilized for these measurements. Correlation coefficient between positive air-ion and Rn indoor concentrations was approximately 0.7. Outdoor and indoor peak values were simultaneous while vertical gradient of concentrations in indoor measurements was evident. The indoor experiments showed that positive air-ion concentration could be an alternative method of radon activity concentration evaluation. PMID:19700332

  2. Quantitative measurements of one-dimensional OH absolute concentration profiles in a methane/air flat flame by bi-directional laser-induced fluorescence

    NASA Astrophysics Data System (ADS)

    Yu, Xin; Yang, Zhen; Peng, Jiang-Bo; Zhang, Lei; Ma, Yu-Fei; Yang, Chao-Bo; Li, Xiao-Hui; Sun, Rui

    2015-11-01

    The one-dimensional (1D) spatial distributions of OH absolute concentration in methane/air laminar premixed flat flame under different equivalence ratios at atmospheric pressure are investigated by using bi-directional laser-induced fluorescence (LIF) detection scheme combined with the direct absorption spectroscopy. The effective peak absorption cross section and the average temperature at a height of 2 mm above the burner are obtained by exciting absorption on the Q1(8) rotational line in the A2Σ+ (ʋ‧ = 0) ← X2Π (ʋ″ = 0) at 309.240 nm. The measured values are 1.86×10-15 cm2 and 1719 K, respectively. Spatial filtering and frequency filtering methods of reducing noise are used to deal with the experimental data, and the smoothing effects are also compared using the two methods. The spatial distribution regularities of OH concentration are obtained with the equivalence ratios ranging from 0.8 to 1.3. The spatial resolution of the measured result is 84 μm. Finally, a comparison is made between the experimental result of this paper and other relevant study results. Project supported by the National Key Scientific Instrument and Equipment Development Projects of China (Grant No. 2012YQ040164), the National Natural Science Foundation of China (Grant Nos. 61275127 and 91441130), the China Postdoctoral Science Foundation (Grant No. 2014M560262), and the Postdoctoral Fellowship in Heilongjiang Province, China (Grant No. LBH-Z14074).

  3. Concentrations of 222Rn, 220Rn and their decay products measured in outdoor air in various rural zones (Morocco) by using solid-state nuclear track detectors and resulting radiation dose to the rural populations.

    PubMed

    Misdaq, M A; Amrane, M; Ouguidi, J

    2010-03-01

    Alpha and beta activities per unit volume of air due to radon ((222)Rn), thoron ((220)Rn) and their progenies were measured in the outdoor air at different locations in Morocco by using both CR-39 and LR-115 type II solid-state nuclear track detectors (SSNTDs). In addition, the radon concentration was continuously measured in one location by using the methods with SSNTDs and AlphaGuard counter. The influence of the geological and meteorological conditions as well as phosphate and building material dust on the radon concentration in the outdoor air of the areas studied was investigated. The committed equivalent doses due to (218)Po and (214)Po radon short-lived progeny were evaluated in different tissues of the respiratory tract of the members of the public from the inhalation of outdoor air. The annual effective dose due to radon short-lived progeny from the inhalation of outdoor air by the members of the rural population was estimated.

  4. Reconstructing the Chernobyl Nuclear Power Plant (CNPP) accident 30 years after. A unique database of air concentration and deposition measurements over Europe.

    PubMed

    Evangeliou, Nikolaos; Hamburger, Thomas; Talerko, Nikolai; Zibtsev, Sergey; Bondar, Yuri; Stohl, Andreas; Balkanski, Yves; Mousseau, Timothy A; Møller, Anders P

    2016-09-01

    30 years after the Chernobyl Nuclear Power Plant (CNPP) accident, its radioactive releases still remain of great interest mainly due to the long half-lives of many radionuclides emitted. Observations from the terrestrial environment, which hosts radionuclides for many years after initial deposition, are important for health and environmental assessments. Furthermore, such measurements are the basis for validation of atmospheric transport models and can be used for constraining the still not accurately known source terms. However, although the "Atlas of cesium deposition on Europe after the Chernobyl accident" (hereafter referred to as "Atlas") has been published since 1998, less than 1% of the direct observations of (137)Cs deposition has been made publicly available. The remaining ones are neither accessible nor traceable to specific data providers and a large fraction of these data might have been lost entirely. The present paper is an effort to rescue some of the data collected over the years following the CNPP accident and make them publicly available. The database includes surface air activity concentrations and deposition observations for (131)I, (134)Cs and (137)Cs measured and provided by Former Soviet Union authorities the years that followed the accident. Using the same interpolation tool as the official authorities, we have reconstructed a deposition map of (137)Cs based on about 3% of the data used to create the Atlas map. The reconstructed deposition map is very similar to the official one, but it has the advantage that it is based exclusively on documented data sources, which are all made available within this publication. In contrast to the official map, our deposition map is therefore reproducible and all underlying data can be used also for other purposes. The efficacy of the database was proved using simulated activity concentrations and deposition of (137)Cs from a Langrangian and a Euleurian transport model. PMID:27376994

  5. Reconstructing the Chernobyl Nuclear Power Plant (CNPP) accident 30 years after. A unique database of air concentration and deposition measurements over Europe.

    PubMed

    Evangeliou, Nikolaos; Hamburger, Thomas; Talerko, Nikolai; Zibtsev, Sergey; Bondar, Yuri; Stohl, Andreas; Balkanski, Yves; Mousseau, Timothy A; Møller, Anders P

    2016-09-01

    30 years after the Chernobyl Nuclear Power Plant (CNPP) accident, its radioactive releases still remain of great interest mainly due to the long half-lives of many radionuclides emitted. Observations from the terrestrial environment, which hosts radionuclides for many years after initial deposition, are important for health and environmental assessments. Furthermore, such measurements are the basis for validation of atmospheric transport models and can be used for constraining the still not accurately known source terms. However, although the "Atlas of cesium deposition on Europe after the Chernobyl accident" (hereafter referred to as "Atlas") has been published since 1998, less than 1% of the direct observations of (137)Cs deposition has been made publicly available. The remaining ones are neither accessible nor traceable to specific data providers and a large fraction of these data might have been lost entirely. The present paper is an effort to rescue some of the data collected over the years following the CNPP accident and make them publicly available. The database includes surface air activity concentrations and deposition observations for (131)I, (134)Cs and (137)Cs measured and provided by Former Soviet Union authorities the years that followed the accident. Using the same interpolation tool as the official authorities, we have reconstructed a deposition map of (137)Cs based on about 3% of the data used to create the Atlas map. The reconstructed deposition map is very similar to the official one, but it has the advantage that it is based exclusively on documented data sources, which are all made available within this publication. In contrast to the official map, our deposition map is therefore reproducible and all underlying data can be used also for other purposes. The efficacy of the database was proved using simulated activity concentrations and deposition of (137)Cs from a Langrangian and a Euleurian transport model.

  6. Rational Normalization of Concentration Measures.

    ERIC Educational Resources Information Center

    Bonckaert, P.; Egghe, L.

    1991-01-01

    Discusses normalization features of good concentration measures and extends the range of values of concentration measures that are population-size-independent. Rational normalization is described, and mathematical formulas for the coefficient of variation, Pratt's measure, the Gini index, Theil's measure, and Atkinson's indices are explained. (14…

  7. Ambient air concentrations of particulate matter from passenger cars.

    PubMed

    Schürmann, D

    1989-01-01

    Using our measurement results on particulate emissions from passenger cars we have calculated ambient air concentrations for various US and European scenarios. This was carried out with the help of mathematical dispersion models for different traffic situations including street canyons and motorways. We have been very conservative in our choice of the scenarios, i.e. we have always used situations in which there are very high stress levels (e.g. constantly high traffic flow instead of average traffic flow). Finally, the thus determined air concentrations are compared with the corresponding air quality standard available from the literature.

  8. Ambient air concentrations of particulate matter from passenger cars.

    PubMed

    Schürmann, D

    1989-01-01

    Using our measurement results on particulate emissions from passenger cars we have calculated ambient air concentrations for various US and European scenarios. This was carried out with the help of mathematical dispersion models for different traffic situations including street canyons and motorways. We have been very conservative in our choice of the scenarios, i.e. we have always used situations in which there are very high stress levels (e.g. constantly high traffic flow instead of average traffic flow). Finally, the thus determined air concentrations are compared with the corresponding air quality standard available from the literature. PMID:2484034

  9. Measurement of heme concentration.

    PubMed

    Sinclair, P R; Gorman, N; Jacobs, J M

    2001-05-01

    Heme (iron protoporphyrin IX) is a prosthetic group for a number of hemoproteins in different tissues (e.g., hemoglobin, myoglobin, cytochrome P-450s, mitochondrial cytochromes, catalases, and peroxidases). Mutations in the biosynthetic pathway can affect the synthesis and/or degradation of heme. Several assays are provided in this unit for quantifying heme: a spectrophotometric assay based on the characteristic absorption spectrum of oxidized and reduced form of the hemochrome formed by replacing the nitrogen ligands with pyridine; a fluorescence assay based on removal of the iron by a heated, strong oxalic acid solution to produce fluorescent protoporphyrin; a reversed-phase HPLC assay to measure heme and intermediates in the synthetic pathway; and a radiometric assay to measure newly synthesized heme in tissue culture cells.

  10. Concentrations of selected contaminants in cabin air of airbus aircrafts.

    PubMed

    Dechow, M; Sohn, H; Steinhanses, J

    1997-07-01

    The concentrations of selected air quality parameters in aircraft cabins were investigated including particle numbers in cabin air compared to fresh air and recirculation air, the microbiological contamination and the concentration of volatile organic compounds (VOC). The Airbus types A310 of Swissair and A340 of Lufthansa were used for measurements. The particles were found to be mainly emitted by the passengers, especially by smokers. Depending on recirculation filter efficiency the recirculation air contained a lower or equal amount of particles compared to the fresh air, whereas the amount of bacteria exceeded reported concentrations within other indoor spaces. The detected species were mainly non-pathogenic, with droplet infection over short distances identified as the only health risk. The concentration of volatile organic compounds (VOC) were well below threshold values. Ethanol was identified as the compound with the highest amount in cabin air. Further organics were emitted by the passengers--as metabolic products or by smoking--and on ground as engine exhaust (bad airport air quality). Cleaning agents may be the source of further compounds.

  11. Measuring Air-Ionizer Output

    NASA Technical Reports Server (NTRS)

    Lonborg, J. O.

    1985-01-01

    Test apparatus checks ion content of airstream from commercial air ionizer. Apparatus ensures ion output is sufficient to neutralize static charges in electronic assembly areas and concentrations of positive and negative ions are balanced.

  12. Indoor Air VOC Concentrations in Suburban and Rural New Jersey

    PubMed Central

    WEISEL, CLIFFORD P.; ALIMOKHTARI, SHAHNAZ; SANDERS, PAUL F.

    2014-01-01

    Indoor VOC air concentrations of many compounds are higher than outdoor concentrations due to indoor sources. However, most studies have measured residential indoor air in urban centers so the typical indoor air levels in suburban and rural regions have not been well characterized. Indoor VOC air concentrations were measured in 100 homes in suburban and rural areas in NJ to provide background levels for investigations of the impact from subsurface contamination sources. Of the 57 target compounds, 23 were not detected in any of the homes, and 14 compounds were detected in at least 50% of the homes with detection limits of ~1 μg/m3. The common compounds identified included aromatic and aliphatic hydrocarbons from mobile sources, halogenated hydrocarbons commonly used in consumer products or from chlorinated drinking water, acetone and 2-butanone emitted from cosmetic products, and Freons. Typical concentrations were in the low μg/m3 range, though values of tens, hundreds or even thousands of μg/m3 were measured in individual homes in which activities related to specific sources of VOCs were reported. Compounds with known similar sources were highly correlated. The levels observed are consistent with concentrations found in the air of urban homes. PMID:19068799

  13. Indoor air VOC concentrations in suburban and rural New Jersey.

    PubMed

    Weisel, Clifford P; Alimokhtari, Shahnaz; Sanders, Paul F

    2008-11-15

    Indoor VOC air concentrations of many compounds are higher than outdoor concentrations due to indoor sources. However, most studies have measured residential indoor air in urban centers so the typical indoor air levels in suburban and rural regions have not been well characterized. Indoor VOC air concentrations were measured in 100 homes in suburban and rural areas in NJ to provide background levels for investigations of the impact from subsurface contamination sources. Of the 57 target compounds, 23 were not detected in any of the homes, and 14 compounds were detected in at least 50% of the homes with detection limits of approximately 1 microg/m3. The common compounds identified included aromatic and aliphatic hydrocarbons from mobile sources, halogenated hydrocarbons commonly used in consumer products or from chlorinated drinking water, acetone and 2-butanone emitted from cosmetic products, and Freons. Typical concentrations were in the low microg/m3 range, though values of tens, hundreds or even thousands of microg/m3 were measured in individual homes in which activities related to specific sources of VOCs were reported. Compounds with known similar sources were highly correlated. The levels observed are consistent with concentrations found in the air of urban homes. PMID:19068799

  14. A statistical inference for concentrations of benzo[a]pyrene partially measured in the ambient air of an industrial city in Korea

    NASA Astrophysics Data System (ADS)

    Kim, Yongku; Seo, Young-Kyo; Baek, Sung-Ok

    2013-12-01

    Although large quantities of air pollutants are released into the atmosphere, they are partially monitored and routinely assessed for their health implications. This paper proposes a statistical model describing the temporal behavior of hazardous air pollutants (HAPs), which can have negative effects on human health. Benzo[a]pyrene (BaP) is selected for statistical modeling. The proposed model incorporates the linkage between BaP and meteorology and is specifically formulated to identify meteorological effects and allow for seasonal trends. The model is used to estimate and forecast temporal fields of BaP conditional on observed (or forecasted) meteorological conditions, including temperature, precipitation, wind speed, and air quality. The effects of BaP on human health are examined by characterizing health indicators, namely the cancer risk and the hazard quotient. The model provides useful information for the optimal monitoring period and projection of future BaP concentrations for both industrial and residential areas in Korea.

  15. Radon concentration measurements in bituminous coal mines.

    PubMed

    Fisne, Abdullah; Okten, Gündüz; Celebi, Nilgün

    2005-01-01

    Radon measurements were carried out in Kozlu, Karadon and Uzülmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) in the study area. The radon concentration measurements were performed on a total of 42 points in those three mines. The annual exposure, the annual effective dose and lifetime fatality risk, which are the important parameters for the health of workers, were estimated based on chronic occupational exposure to the radon gas, which is calculated using UNCEAR-2000 and ICRP-65 models. The radon concentrations at several coal production faces are higher than the action level of 1000 Bq m(-3). It is suggested that the ventilation rates should be rearranged to reduce the radon concentration.

  16. Air pressure measurement

    NASA Technical Reports Server (NTRS)

    Ballard, H. N.

    1978-01-01

    The pressure measurement was made by a Model 830J Rosemont sensor which utilized the principle of a changing pressure to change correspondingly the capacitance of the pressure sensitive element. The sensor's range was stated to be from zero to 100 Torr (14 km); however, the sensor was not activated until an altitude of 20 km (41 Torr) was reached during the balloon ascent. The resolution of the sensor was specified by the manufacturer as infinitesimal; however, associated electronic and pressure readout systems limit the resolution to .044 Torr. Thus in the vicinity of an altitude of 30 km the pressure resolution corresponded to an altitude resolution of approximately 33 meters.

  17. Ozone concentrations in air flowing into New York State

    NASA Astrophysics Data System (ADS)

    Aleksic, Nenad; Kent, John; Walcek, Chris

    2016-09-01

    Ozone (O3) concentrations measured at Pinnacle State Park (PSPNY), very close to the southern border of New York State, are used to estimate concentrations in air flowing into New York. On 20% of the ozone season (April-September) afternoons from 2004 to 2015, mid-afternoon 500-m back trajectories calculated from PSPNY cross New York border from the south and spend less than three hours in New York State, in this area of negligible local pollution emissions. One-hour (2p.m.-3p.m.) O3 concentrations during these inflowing conditions were 46 ± 13 ppb, and ranged from a minimum of 15 ppb to a maximum of 84 ppb. On average during 2004-2015, each year experienced 11.8 days with inflowing 1-hr O3 concentrations exceeding 50 ppb, 4.3 days with O3 > 60 ppb, and 1.5 days had O3 > 70 ppb. During the same period, 8-hr average concentrations (10a.m. to 6p.m.) exceeded 50 ppb on 10.0 days per season, while 3.9 days exceeded 60 ppb, and 70 ppb was exceeded 1.2 days per season. Two afternoons of minimal in-state emission influences with high ozone concentrations were analyzed in more detail. Synoptic and back trajectory analysis, including comparison with upwind ozone concentrations, indicated that the two periods were characterized as photo-chemically aged air containing high inflowing O3 concentrations most likely heavily influenced by pollution emissions from states upwind of New York including Pennsylvania, Tennessee, West Virginia, and Ohio. These results suggest that New York state-level attempts to comply with National Ambient Air Quality Standards by regulating in-state O3 precursor NOx and organic emissions would be very difficult, since air frequently enters New York State very close to or in excess of Federal Air Quality Standards.

  18. Air radon concentration decrease in a waste water treatment plant.

    PubMed

    Juste, B; Ortiz, J; Verdú, G; Martorell, S

    2015-06-01

    (222)Rn is a naturally occurring gas created from the decay of (226)Ra. The long-term health risk of breathing radon is lung cancer. One particular place where indoor radon concentrations can exceed national guidelines is in wastewater treatment plants (WWTPs) where treatment processes may contribute to ambient airborne concentrations. The aim of this paper was to study the radon concentration decrease after the application of corrective measures in a Spanish WWTP. According to first measures, air radon concentration exceeded International Commission Radiologica1 Protection (ICRP) normative (recommends intervention between 400 and 1000 Bq m(-3)). Therefore, the WWTP improved mechanical forced ventilation to lower occupational exposure. This measure allowed to increase the administrative controls, since the limitation of workers access to the plant changed from 2 h d(-1) (considering a maximum permissible dose of 20 mSv y(-1) averaged over 5 y) to 7 h d(-1).

  19. Air radon concentration decrease in a waste water treatment plant.

    PubMed

    Juste, B; Ortiz, J; Verdú, G; Martorell, S

    2015-06-01

    (222)Rn is a naturally occurring gas created from the decay of (226)Ra. The long-term health risk of breathing radon is lung cancer. One particular place where indoor radon concentrations can exceed national guidelines is in wastewater treatment plants (WWTPs) where treatment processes may contribute to ambient airborne concentrations. The aim of this paper was to study the radon concentration decrease after the application of corrective measures in a Spanish WWTP. According to first measures, air radon concentration exceeded International Commission Radiologica1 Protection (ICRP) normative (recommends intervention between 400 and 1000 Bq m(-3)). Therefore, the WWTP improved mechanical forced ventilation to lower occupational exposure. This measure allowed to increase the administrative controls, since the limitation of workers access to the plant changed from 2 h d(-1) (considering a maximum permissible dose of 20 mSv y(-1) averaged over 5 y) to 7 h d(-1). PMID:25971342

  20. Measuring Hydrogen Concentrations in Metals

    NASA Technical Reports Server (NTRS)

    Danford, M. D.

    1985-01-01

    Commercial corrosion-measurement system adapted to electrochemical determination of hydrogen concentrations in metals. New technique based on diffusion of hydrogen through foil specimen of metal. In sample holder, hydrogen produced on one side of foil, either by corrosion reaction or by cathodic current. Hydrogen diffused through foil removed on other side by constant anode potential, which leads to oxidation of hydrogen to water. Anode current is measure of concentration of hydrogen diffusing through foil. System used to study hydrogen uptake, hydrogen elimination by baking, effect of heat treatment, and effect of electroplating on high-strength steels.

  1. Evaluation of innovative air-monitoring technologies for the measurement of ambient concentrations of ozone and its precursors at the 1996 Summer Olympics

    NASA Astrophysics Data System (ADS)

    Gamiles, Donald S.; Rodgers, Michael; Meeker, Charles; Olive, Brent S.; Simpson, Orman A.

    1997-05-01

    An open path Fourier transform IR spectrometer and an ultra- violet differential optical absorption spectrometer were used during the 1996 Atlanta Olympics games to monitor for ambient ozone and its precursors near the Olympic Village. Both systems were operated continuously before, during, and after the increase in Atlanta's population associated with the Summer games. The study utilized the massive changes in population patterns to observe and measure changes in local air quality due to an increased local population. A second goal of the program was to evaluate both open path instruments in continuous field use over a period of several weeks. The evaluation included the following criteria: instrumentation operability, system precision and accuracy, detection capability, and over-all ease of use. Both open path systems selected and measured ambient levels of ozone. A limited number of ozone precursors were detected. The study was sponsored by the Georgia Institute of Technology's Air Quality Laboratory, the US Department of Energy, and the US Environmental Protection Agency.

  2. H2S, VOC, TOC, electronic noses and odour concentration: use and comparison of different parameters for emission measurement on air treatment systems.

    PubMed

    Franke, W; Frechen, F-B; Giebel, S

    2009-01-01

    Odour measurement via olfactometry is expensive and has a low accuracy compared with chemical or physical methods. In addition, olfactometry is not suited for online monitoring. Hence, an accurate online method for emission measurement would be an enormous improvement. There are several options to more or less replace the offline olfactometry by online measurement available today. Most common are H2S-concentration as a single gas parameter and VOC and TOC as composite parameters. A fairly new development are multi sensor arrays, usually referred to as "electronic noses" which carry out non-specific gas measurement and deliver measurement data that can visualized as a fingerprint diagram. This paper outlines the use of these different parameters and compares the results to those gained via olfactometry of several case studies.

  3. Concentrations of 222Rn, 220Rn and their decay products measured in outdoor air in various rural zones (Morocco) by using solid-state nuclear track detectors and resulting radiation dose to the rural populations.

    PubMed

    Misdaq, M A; Amrane, M; Ouguidi, J

    2010-03-01

    Alpha and beta activities per unit volume of air due to radon ((222)Rn), thoron ((220)Rn) and their progenies were measured in the outdoor air at different locations in Morocco by using both CR-39 and LR-115 type II solid-state nuclear track detectors (SSNTDs). In addition, the radon concentration was continuously measured in one location by using the methods with SSNTDs and AlphaGuard counter. The influence of the geological and meteorological conditions as well as phosphate and building material dust on the radon concentration in the outdoor air of the areas studied was investigated. The committed equivalent doses due to (218)Po and (214)Po radon short-lived progeny were evaluated in different tissues of the respiratory tract of the members of the public from the inhalation of outdoor air. The annual effective dose due to radon short-lived progeny from the inhalation of outdoor air by the members of the rural population was estimated. PMID:19887516

  4. Reconstructing the atmospheric concentration and emissions of CF4, C2F6 and C3F8 prior to direct atmospheric measurements, using air from polar firn and ice

    NASA Astrophysics Data System (ADS)

    Trudinger, Cathy; Etheridge, David; Sturges, William; Vollmer, Martin; Miller, Benjamin; Worton, David; Rigby, Matt; Krummel, Paul; Martinerie, Patricia; Witrant, Emmanuel; Rayner, Peter; Battle, Mark; Blunier, Thomas; Fraser, Paul; Laube, Johannes; Mani, Frances; Mühle, Jens; O'Doherty, Simon; Schwander, Jakob; Steele, Paul

    2015-04-01

    Perfluorocarbons are very potent and long-lived greenhouse gases in the atmosphere, released predominantly during aluminium production, electronic chip manufacture and refrigeration. Mühle et al. (2010) presented records of the concentration and inferred emissions of CF4 (PFC-14), C2F6 (PFC-116) and C3F8 (PFC-218) from the 1970s up to 2008, using measurements from the Cape Grim Air Archive and a suite of tanks with old Northern Hemisphere air, and the AGAGE in situ network. Mühle et al. (2010) also estimated pre-industrial concentrations of these compounds from a small number of polar firn and ice core samples. Here we present measurements of air from polar firn at four sites (DSSW20K, EDML, NEEM and South Pole) and from air bubbles trapped in ice at two sites (DE08 and DE08-2), along with recent atmospheric measurements to give a continuous record of concentration from preindustrial levels up to the present. We estimate global emissions (with uncertainties) consistent with the concentration records. The uncertainty analysis takes into account uncertainties in characterisation of the age of air in firn and ice by the use of two different (independently-calibrated) firn models (the CSIRO and LGGE-GIPSA firn models). References Mühle, J., A.L. Ganesan, B.R. Miller, P.K. Salameh, C.M. Harth, B.R. Greally, M. Rigby, L.W. Porter, L. P. Steele, C.M. Trudinger, P.B. Krummel, S. O'Doherty, P.J. Fraser, P.G. Simmonds, R.G. Prinn, and R.F. Weiss, Perfluorocarbons in the global atmosphere: tetrafluoromethane, hexafluoroethane, and octafluoropropane, Atmos. Chem. Phys., 10, 5145-5164, doi:10.5194/acp-10-5145-2010, 2010.

  5. Estimating the radon concentration in water and indoor air.

    PubMed

    Maged, A F

    2009-05-01

    The paper presents the results of radon concentration measurements in the vicinity of water, indoor air and in contact to building walls. The investigations were carried out using CR-39 track detectors. Samples of ground water flowing out of many springs mostly in Arabian Gulf area except one from Germany have been studied. The results are compared with international recommendations and the values are found to be lower than the recommended value. Measuring the mean indoor radon concentrations in air and in contact to building walls in the dwellings of Kuwait University Campus were found 24.2 +/- 7.7, and 462 +/- 422 Bq m(-3) respectively. These values lead to average effective dose equivalent rates of 1.3 +/- 0.4 and 23 +/- 21 mSv year(-1), respectively.

  6. Long-memory property in air pollutant concentrations

    NASA Astrophysics Data System (ADS)

    Chelani, Asha

    2016-05-01

    In the present paper, long-memory in air pollutant concentrations is reviewed and outcome of the past studies is analyzed to provide the possible mechanism behind temporal evolution of air pollutant concentrations. It is observed that almost all the studies show air pollutant concentrations over time possess persistence up to a certain limit. Self-organized criticality of air pollution, multiplicative process of pollutant concentrations, and uniformity in emission sources leading to self-organized criticality are few of the phenomena behind the persistent property of air pollutant concentrations. The self-organized criticality of air pollution is linked to atmosphere's self-cleansing mechanism. This demonstrates that inspite of increasing anthropogenic emissions, self-organized criticality of air pollution is sustained and has low influence of human interventions. In the future, this property may, however, be perturbed due to continuous air pollution emissions, which may influence the accuracy in predictions.

  7. Amine Measurements in Boreal Forest Air

    NASA Astrophysics Data System (ADS)

    Hemmilä, Marja; Hellén, Heidi; Makkonen, Ulla; Hakola, Hannele

    2015-04-01

    Amines are reactive, volatile bases in the air with a general formula of RNH2, R2NH or R3N. Especially small amines can stabilize sulphuric acid clusters and hence affect nucleation. Amines react rapidly with hydroxyl radical (OH˙) thus affecting oxidative capacity of the atmosphere. The amine concentrations are higher in forest air than in urban air (Hellén et al., 2014), but the sources are not known. In order to get more information concerning amine sources, we conducted a measurement campaign in a boreal forest. At SMEAR II station at Hyytiälä, Southern Finland (61°510'N, 24°170'E, 180 m a.s.l.) The measurements cover seven months, from June to December 2014. For sampling and measuring we used MARGA (The instrument for Measuring AeRosols and Gases in Ambient air) which is an on-line ion chromatograph (IC) connected to a sampling system. The IC component of the MARGA system was coupled to an electrospray ionization quadrupole mass spectrometer (MS) to improve sensitivity of amine measurements. This new set-up enabled amine concentration measurements in ambient air both in aerosol and gas phases with a time resolution of only 1 hour. With MARGA-MS we analysed 7 different amines: monomethylamine (MMA), dimethylamine (DMA), trimethylamine (TMA), ethylamine (EA), diethylamine (DEA), propylamine (PA) and butylamine (BA). In preliminary data-analysis we found out, that in June and July most of the measured amines were in gas phase, and particle phase amine concentrations were mostly under detection limits (<1.7 pptv). In June the gaseous amine concentrations were higher than in July. The measured concentrations of gaseous amines followed temperature variation, which could indicate that amines are produced and emitted from the environment or re-emitted from the surfaces as temperature rises after deposition during night-time. All measured amines had similar diurnal variation with maxima during afternoon and minima during night. Results from other months will also

  8. Concentrated Solar Air Conditioning for Buildings Project

    NASA Technical Reports Server (NTRS)

    McLaughlin, Rusty

    2010-01-01

    This slide presentation reviews project to implement the use of solar power to provide air conditioning for NASA buildings. Included is an overall conceptual schematic, and an diagram of the plumbing and instrumentation for the project. The use of solar power to power air conditioning in buildings, particularly in the Southwest, could save a significant amount of money. DOD studies have concluded that air conditioning accounts for 30-60% of total energy expenditures.

  9. Source term estimation of radioxenon released from the Fukushima Dai-ichi nuclear reactors using measured air concentrations and atmospheric transport modeling.

    PubMed

    Eslinger, P W; Biegalski, S R; Bowyer, T W; Cooper, M W; Haas, D A; Hayes, J C; Hoffman, I; Korpach, E; Yi, J; Miley, H S; Rishel, J P; Ungar, K; White, B; Woods, V T

    2014-01-01

    Systems designed to monitor airborne radionuclides released from underground nuclear explosions detected radioactive fallout across the northern hemisphere resulting from the Fukushima Dai-ichi Nuclear Power Plant accident in March 2011. Sampling data from multiple International Modeling System locations are combined with atmospheric transport modeling to estimate the magnitude and time sequence of releases of (133)Xe. Modeled dilution factors at five different detection locations were combined with 57 atmospheric concentration measurements of (133)Xe taken from March 18 to March 23 to estimate the source term. This analysis suggests that 92% of the 1.24 × 10(19) Bq of (133)Xe present in the three operating reactors at the time of the earthquake was released to the atmosphere over a 3 d period. An uncertainty analysis bounds the release estimates to 54-129% of available (133)Xe inventory.

  10. Atmospheric light air ion concentrations and related meteorologic factors in Rezekne city, Latvia.

    PubMed

    Skromulis, Andris; Noviks, Gotfrids

    2012-04-01

    The well-minded impact of light negative air ions on human organism is still under discussion. The measurements of air ions are not widespread in Latvia yet. The paper presents new results of air pollution evaluation in Rezekne city. Measurements of positive and negative air ion concentrations in Rezekne city were taken during the spring, summer and autumn 2009 and during the winter 2010. Measurements were taken by portative air ions counter "Sapfir-3M" in eight different points of Rezekne city thrice a day. The concentrations of positive and negative air ions with mobility factor k > or = 0.4 cm2 V(-1) s(-1) were measured. Temperature, relative humidity, wind velocity, direction, etc., were also taken into account. The approximate interconnection between ionization and chemical and mechanical air pollution in relation with meteorological conditions was analyzed. The highest level of air ion concentration was observed in mornings, whereas in afternoons this concentration level decreased due to the growth of anthropogenic air pollution in the city, as light air ions, because of their charge, promoted the coagulation and the settlement of pollution particles. This regularity is typical for summer, whereas in spring, autumn and winter it is not characteristic. The unipolarity factor was usually less than 1 in mornings, but usually larger than 1 in afternoons especially in the most polluted city areas where minor concentration of air ions was detected. The ionization level is an original indicator of energetic saturation and aerosol pollution of atmospheric air.

  11. Air pollution measurements from satellites

    NASA Technical Reports Server (NTRS)

    Ludwig, C. B.; Griggs, M.; Malkmus, W.; Bartle, E. R.

    1973-01-01

    A study is presented on the remote sensing of gaseous and particulate air pollutants which is an extension of a previous report. Pollutants can be observed by either active or passive remote sensing systems. Calculations discussed herein indicate that tropospheric CO, CO2, SO2, NO2, NH3, HCHO, and CH4 can be measured by means of nadir looking passive systems. Additional species such as NO, HNO3, O3, and H2O may be measured in the stratosphere through a horizon experiment. A brief theoretical overview of resonance Raman scattering and resonance fluorescence is given. It is found that radiance measurements are most promising for general global applications, and that stratospheric aerosols may be measured using a sun occultation technique. The instrumentation requirements for both active and passive systems are examined and various instruments now under development are described.

  12. Source Term Estimation of Radioxenon Released from the Fukushima Dai-ichi Nuclear Reactors Using Measured Air Concentrations and Atmospheric Transport Modeling

    SciTech Connect

    Eslinger, Paul W.; Biegalski, S.; Bowyer, Ted W.; Cooper, Matthew W.; Haas, Derek A.; Hayes, James C.; Hoffman, Ian; Korpach, E.; Yi, Jing; Miley, Harry S.; Rishel, Jeremy P.; Ungar, R. Kurt; White, Brian; Woods, Vincent T.

    2014-01-01

    Systems designed to monitor airborne radionuclides released from underground nuclear explosions detected radioactive fallout from the Fukushima Daiichi nuclear accident in March 2011. Atmospheric transport modeling (ATM) of plumes of noble gases and particulates were performed soon after the accident to determine plausible detection locations of any radioactive releases to the atmosphere. We combine sampling data from multiple International Modeling System (IMS) locations in a new way to estimate the magnitude and time sequence of the releases. Dilution factors from the modeled plume at five different detection locations were combined with 57 atmospheric concentration measurements of 133-Xe taken from March 18 to March 23 to estimate the source term. This approach estimates that 59% of the 1.24×1019 Bq of 133-Xe present in the reactors at the time of the earthquake was released to the atmosphere over a three day period. Source term estimates from combinations of detection sites have lower spread than estimates based on measurements at single detection sites. Sensitivity cases based on data from four or more detection locations bound the source term between 35% and 255% of available xenon inventory.

  13. Review of air flow measurement techniques

    SciTech Connect

    McWilliams, Jennifer

    2002-12-01

    Airflow measurement techniques are necessary to determine the most basic of indoor air quality questions: ''Is there enough fresh air to provide a healthy environment for the occupants of the building?'' This paper outlines airflow measurement techniques, but it does not make recommendations for techniques that should be used. The airflows that will be discussed are those within a room or zone, those between rooms or zones, such as through doorways (open or closed) or passive vents, those between the building and outdoors, and those through mechanical air distribution systems. Techniques that are highlighted include particle streak velocimetry, hot wire anemometry, fan pressurization (measuring flow at a given pressure), tracer gas, acoustic methods for leak size determination, the Delta Q test to determine duct leakage flows, and flow hood measurements. Because tracer gas techniques are widely used to measure airflow, this topic is broken down into sections as follows: decay, pulse injection, constant injection, constant concentration, passive sampling, and single and multiple gas measurements for multiple zones.

  14. Variability of air ion concentrations in urban Paris

    NASA Astrophysics Data System (ADS)

    Dos Santos, V. N.; Herrmann, E.; Manninen, H. E.; Hussein, T.; Hakala, J.; Nieminen, T.; Aalto, P. P.; Merkel, M.; Wiedensohler, A.; Kulmala, M.; Petäjä, T.; Hämeri, K.

    2015-12-01

    Air ion concentrations influence new particle formation and consequently the global aerosol as potential cloud condensation nuclei. We aimed to evaluate air ion concentrations and characteristics of new particle formation events (NPF) in the megacity of Paris, France, within the MEGAPOLI (Megacities: Emissions, urban, regional and Global Atmospheric Pollution and climate effects, and Integrated tools for assessment and mitigation) project. We measured air ion number size distributions (0.8-42 nm) with an air ion spectrometer and fine particle number concentrations (> 6 nm) with a twin differential mobility particle sizer in an urban site of Paris between 26 June 2009 and 4 October 2010. Air ions were size classified as small (0.8-2 nm), intermediate (2-7 nm), and large (7-20 nm). The median concentrations of small and large ions were 670 and 680 cm-3, respectively, (sum of positive and negative polarities), whereas the median concentration of intermediate ions was only 20 cm-3, as these ions were mostly present during new particle formation bursts, i.e. when gas-to-particle conversion produced fresh aerosol particles from gas phase precursors. During peaks in traffic-related particle number, the concentrations of small and intermediate ions decreased, whereas the concentrations of large ions increased. Seasonal variations affected the ion population differently, with respect to their size and polarity. NPF was observed in 13 % of the days, being most frequent in spring and late summer (April, May, July, and August). The results also suggest that NPF was favoured on the weekends in comparison to workdays, likely due to the lower levels of condensation sinks in the mornings of weekends (CS weekdays 09:00: 18 × 10-3 s-1; CS weekend 09:00: 8 × 10-3 s-1). The median growth rates (GR) of ions during the NPF events varied between 3 and 7 nm h-1, increasing with the ion size and being higher on workdays than on weekends for intermediate and large ions. The median GR of

  15. BOREAS TGB-7 Ambient Air Herbicide and Organochlorine Concentration Data

    NASA Technical Reports Server (NTRS)

    Waite, Don; Hall, Forrest G. (Editor); Conrad, Sara K. (Editor)

    2000-01-01

    The BOReal Ecosystem-Atmosphere Study Trace Gas Biogeochemistry (BOREAS TGB)-7 team measured the concentration and flux of several agricultural pesticides in air, rainwater, and dry deposition samples in order to determine the associated yearly deposition rates. This data set contains information on the ambient air concentration of seven herbicides [2,4- dichlorophenoxyacidic_acid (2,4-D), bromoxynil, dicamb, 2-methyl-4-chlorophenoxyacetic acid (MCPA), triallate, trifluralin, and diclop-methyl] known to appear in the atmosphere of the Canadian prairies. Also, the concentration of three herbicides (atrazine, alachlor, and metolachlor), two groups of insecticides (lindane and breakdown products and dichloro-diphenyl-trichloroethane (DDT) and breakdown products), and several polychlorinated biphenyls commonly used in the central United States was measured. All of these chemicals are reported, in the literature, to be transported in the atmosphere. Many have been reported to occur in boreal and arctic food chains. The sampling was carried out from 16-Jun to 13-Aug-1993 and 04-May to 20-Jul-1994 at the BOREAS site in the Prince Albert National Park (Waskesiu). The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884).

  16. 40 CFR Appendix IV to Part 266 - Reference Air Concentrations*

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Reference Air Concentrations* IV Appendix IV to Part 266 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... MANAGEMENT FACILITIES Pt. 266, App. IV Appendix IV to Part 266—Reference Air Concentrations* Constituent...

  17. Concentrations of air toxics in motor vehicle-dominated environments.

    PubMed

    Fujita, Eric M; Campbell, David E; Zielinska, Barbara; Arnott, William P; Chow, Judith C

    2011-02-01

    We at the Desert Research Institute (DRI*) measured volatile organic compounds (VOCs), including several mobile-source air toxics (MSATs), particulate matter with a mass mean aerodynamic diameter < or = 2.5 pm (PM2.5), black carbon (BC), nitrogen oxides (NOx), particulate matter (PM), and carbon monoxide (CO) on highways in Los Angeles County during summer and fall 2004, to characterize the diurnal and seasonal variations in measured concentrations related to volume and mix of traffic. Concentrations of on-road pollutants were then compared to corresponding measurements at fixed monitoring sites. The on-road concentrations of CO and MSATs were higher in the morning under stable atmospheric conditions and during periods of higher traffic volumes. In contrast, BC concentrations, measured as particulate light absorption, were higher on truck routes during the midday sampling periods despite more unstable atmospheric conditions. Compared to the measurements at the three near-road sites, the 1-hour averages of on-road BC concentrations were as much as an order of magnitude higher. The peak 1-minute average concentrations were two orders of magnitude higher for BC and were between two and six times higher for PM2.5 mass. The on-road concentrations of benzene, toluene, ethylbenzene, and xylenes (BTEX) during the summer were 3.5 +/- 0.7 and 1.2 +/- 0.6 times higher during morning and afternoon commuting periods, respectively, compared to annual average 24-hour concentrations measured at air toxic monitoring network sites. These ratios were higher during the fall, with smaller diurnal differences (4.8 +/- 0.7 and 3.9 +/- 0.6 for morning and afternoon commuting periods, respectively). Ratios similar to those for BTEX were obtained for 1,3-butadiene (BD) and styrene. On-road concentrations of formaldehyde and acetaldehyde were up to two times higher than at air toxics monitoring sites, with fall ratios slightly higher than summer ratios. Chemical mass balance (CMB) receptor

  18. Air pollution measurements in traffic tunnels.

    PubMed

    De Fré, R; Bruynseraede, P; Kretzschmar, J G

    1994-10-01

    Air pollution measurements during April 1991 are reported from the Craeybeckx highway tunnel in Antwerp, Belgium. The tunnel was used daily by an average of 45,000 vehicles, of which 60% were gasoline fueled passenger cars, 20% diesel cars, and 20% trucks. Of the gasoline cars, only 3% had three-way catalysts. Tunnel air concentrations of nitrogen oxides, sulphur dioxide, carbon dioxide, carbon monoxide, nonmethane hydrocarbons, volatile organic compounds, polycyclic aromatic hydrocarbons, and lead are presented. The traffic emissions in the tunnel are calculated by the carbon balance method, which uses the increase of the total carbon concentration in the tunnel air as the reference quantity. Division of the concentration of any pollutant by the total carbon concentration gives emission factors per kilogram of carbon. These emission factors can be converted directly to emissions relative to fuel consumption or per kilometer. The fraction of diesel used in the tunnel was derived from sulphur to carbon ratios in tunnel air. A calculation procedure with breakdown of emission factors according to vehicle categories was used to estimate countrywide emissions. The estimated emissions were compared to results from the Flanders Emissions Inventory [Emissie Inventaris Vlaamse Regio (EIVR)] and calculated emissions according to the emission factors proposed by the European Commissions CORINAIR Working Group. For NOx there is excellent agreement. For carbon monoxide and hydrocarbons, the tunnel data produced higher emissions than the CORINAIR model would predict but lower than the official EIVR statistics. The estimated lead emissions from traffic are found to be 22 to 29% of the lead in gasoline.

  19. Effect of backyard burning on dioxin deposition and air concentrations.

    PubMed

    Wevers, M; De Fré, R; Desmedt, M

    2004-03-01

    The influence from open burning of garden and household waste on locally measured dioxin deposition and air concentrations was evaluated in three sets of experiments: the combustion of garden waste in barrels and in open fires, and the incineration of household waste in an empty oil drum. Each set was composed of eight individual experiments over 4 h. Deposition gauges were located 20 m NE, SE, SW and NW with respect to the source and on a background location at 400 m SW. Air samples were taken in the plume with a medium volume sampler equipped with a quartz filter and a polyurethane plug. The results illustrate deposition increments in the wind direction at a distance of 20 m from the source of 0.8 pg TEQ/m2 day for garden waste and 2.5 pg TEQ/m2 day for household waste. Concentrations in the plume were increased by 160-580 fg TEQ/m3 over a period of 12 and 31 h respectively. Expressed at a reference CO2 concentration of 9% this corresponds with a range from 0.8 to 3.6 ng TEQ/m3, which is comparable with a poorly controlled MSWI. Emission factors in the order of magnitude of 4.5 ng TEQ/kg combusted garden waste and 35 ng TEQ/kg burned municipal waste were determined.

  20. Ozone concentration in the cabin of a Gates Learjet measured simultaneously with atmospheric ozone concentrations

    NASA Technical Reports Server (NTRS)

    Briehl, D.; Perkins, P. J.

    1978-01-01

    A Gates Learjet Model 23 was instrumented with monitors to measure simultaneously the atmospheric and the cabin concentrations of ozone at altitudes up to 13 kilometers. Six data flights were made in February 1978. Results indicated that only a small amount of the atmospheric ozone is destroyed in the cabin pressurization system. Ozone concentrations measured in the cabin near the conditioned-air outlets were only slightly lower than the atmospheric ozone concentration. For the two cabin configurations tested, the ozone retention in the cabin was 63 and 41 percent of the atmospheric ozone concentration. Maximum cabin ozone concentration measured during these flights was 410 parts per billion by volume.

  1. Analysis of Mobile Source Air Toxics (MSATS)–Near-Road VOC and CarbonylConcentrations

    EPA Science Inventory

    This presentation examines data from a year-long study of measured near-road mobile source air toxic (MSAT) concentrations and compares these data with modeled 2005 National Air Toxic Assessment (NATA) results. Field study measurements were collected during a field campaign in ...

  2. Measurement of air entrainment in plasma jets

    NASA Astrophysics Data System (ADS)

    Fincke, J. R.; Rodriquez, R.; Pentecost, C. G.

    The concentration and temperature of air entrained into argon and helium plasma jets has been measured using coherent anti-Stokes Raman spectroscopy (CARS). The argon plasma flow field is characterized by a short region of well behaved laminar flow near the nozzle exit followed by an abrupt transition to turbulence. Once the transition of turbulence occurs, air is rapidly mixed into the jet core. The location of the transition region is determined by the rapid cooling of the jet and the resulting increase in Reynolds number. In contrast, the helium plasma flow field never exceeds a Reynolds number of 200 and remains laminar. The entrainment process in this case is controlled by molecular diffusion rather than turbulent mixing.

  3. Measurement of air entrainment in plasma jets

    SciTech Connect

    Fincke, J.R.; Rodriquez, R.; Pentecost, C.G.

    1990-01-01

    The concentration and temperature of air entrained into argon and helium plasma jets has been measured using coherent anti-Stokes Raman spectroscopy (CARS). The argon plasma flow field is characterized by a short region of well behaved laminar flow near the nozzle exit followed by an abrupt transition to turbulence. Once the transition of turbulence occurs, air is rapidly mixed into the jet core. The location of the transition region is determined by the rapid cooling of the jet and the resulting increase in Reynolds number. In contrast, the helium plasma flow field never exceeds a Reynolds number of 200 and remains laminar. The entrainment process in this case is controlled by molecular diffusion rather than turbulent mixing. 9 refs., 5 figs., 1 tab.

  4. Measurement of air-surface exchange of speciated nitrogen and sulfur compounds using a modified MARGA 2S: ? Concentrations and fluxes above a grass field

    EPA Science Inventory

    Improved measurement methods are needed to characterize dry deposition of sulfur and nitrogen compounds to assess ecosystem exposure to nutrients and acidifying compounds and to develop atmospheric deposition budgets in support of critical loads assessments. The purpose of this s...

  5. Minanre Gas Concentrators For Air Sampling

    SciTech Connect

    Dr. Seung Ho Hong

    2001-03-01

    The goal of this project was to demonstrate the feasibility of a compact, lightweight, gas-sampling device with rapid-cycle-time characteristics. The highlights of our Phase I work include: (1) Demonstration of a compact gas sampler with integrated heater. This device has an order of magnitude greater adsorption capacity and much faster heating/cooling times than commercial sorbent tubes. (2) Completion of computational fluid dynamics modeling of the gas sampler to determine airflow characteristics for various design options. These modeling efforts guided the development and testing of the Mesochannel Gas Sampler prototype. (3) Testing of the Mesochannel Gas Sampler in parallel with tests of two packed-bed samplers. These tests showed the Mesochannel Gas Sampler represents a substantial improvement compared with the packed-bed approach. Our mesochannel heat-exchanger/adsorber architecture allows very efficient use of adsorbent mass, high adsorbent loadings, and very low pressure drop, which makes possible very high air-sampling rates using a simple, low-power fan. This device is well-suited for collecting samples of trace-level contaminants. The integrated heater, which forms the adsorbent-coated mesochannel walls, allows direct heating of the adsorbent and results in very rapid desorption of the adsorbed species. We believe the Mesochannel Gas Sampler represents a promising technology for the improvement of trace-contaminant detection limits. In our Phase II proposal, we outline several improvements to the gas sampler that will further improve its performance.

  6. Time variations of 222Rn concentration and air exchange rates in a Hungarian cave.

    PubMed

    Nagy, Hedvig Éva; Szabó, Zsuzsanna; Jordán, Gyozo; Szabó, Csaba; Horváth, Akos; Kiss, Attila

    2012-09-01

    A long-term radon concentration monitoring was carried out in the Pál-völgy cave, Budapest, Hungary, for 1.5 years. Our major goal was to determine the time dependence of the radon concentration in the cave to characterise the air exchange and define the most important environmental parameters that influence the radon concentration inside the cave. The radon concentration in the cave air was measured continuously by an AlphaGuard radon monitor, and meteorological parameters outside the cave were collected simultaneously. The air's radon concentration in the cave varied between 104 and 7776 Bq m(-3), the annual average value was 1884±85 Bq m(-3). The summer to winter radon concentration ratio was as high as 21.8. The outside air temperature showed the strongest correlation with the radon concentration in the cave, the correlation coefficient (R) was 0.76. PMID:22462600

  7. CONCENTRATIONS OF TOXIC AIR POLLUTANTS IN THE U.S. SIMULATED BY AN AIR QUALITY MODEL

    EPA Science Inventory

    As part of the US National Air Toxics Assessment, we have applied the Community Multiscale Air Quality Model, CMAQ, to study the concentrations of twenty gas-phase, toxic, hazardous air pollutants (HAPs) in the atmosphere over the continental United States. We modified the Carbo...

  8. A pulsed electron-photon fluorescence diagnostic technique for temperature and specie concentration measurement at points in relatively dense, unseedded air flows

    NASA Technical Reports Server (NTRS)

    Muntz, E. P.; Kunc, J. A.; Erwin, D. A.

    1987-01-01

    An analysis is presented on the use of the fluorescence stimulated by combined pulsed electron and photon beams for the study of gas flows up to densities equivalent to an altitude of about 20 km (number density of about 3 x 10 to the 18th/cu cm). The electron beam acts as a pump, requiring no seed gas, to provide a localized concentration of ions or excited state neutrals that can be probed by saturation optical pulses. A short pulse (10ns) electron beam can be used by itself to provide effectively quench-free emission up to number densities of around 10 to the 18th/cm, but is is difficult to maintain satisfactory spatial resolution at this high density. The use of a nearly simultaneous strong optical pulse increases the flexibility of the diagnostic technique, permitting use at densities greater than 10 to the 18th/cu cm with good spatial resolution. The use of flash X-ray sources combined with optical probing also appears promising for densities above 10 to the 19th/cu cm.

  9. Daily and seasonal variations in radon activity concentration in the soil air.

    PubMed

    Műllerová, Monika; Holý, Karol; Bulko, Martin

    2014-07-01

    Radon activity concentration in the soil air in the area of Faculty of Mathematics, Physics and Informatics (FMPI) in Bratislava, Slovak Republic, has been continuously monitored since 1994. Long-term measurements at a depth of 0.8 m and short-term measurements at a depth of 0.4 m show a high variability in radon activity concentrations in the soil. The analysis of the data confirms that regular daily changes in radon activity concentration in the soil air depend on the daily changes in atmospheric pressure. It was also found that the typical annual courses of the radon activity concentration in the soil air (with summer minima and winter maxima) were disturbed by mild winter and heavy summer precipitation. Influence of precipitation on the increase in the radon activity concentration in the soil air was observed at a depth of 0.4 m and subsequently at a depth of 0.8 m.

  10. Ultralow Concentration Mercury Treatment Using Chemical Reduction and Air Stripping

    SciTech Connect

    Looney, B.B.

    2001-05-21

    Field, laboratory and engineering data confirmed the efficacy of chemical reduction and air stripping as an ultralow concentration mercury treatment concept for water containing Hg(II). The simple process consists of dosing the water with low levels of stannous chloride (Sn(II)) to cover the mercury to Hg degrees. This mercury species can easily be removed from the water by air stripping or sparging.

  11. Concentrations of propoxur in air following repeated indoor applications.

    PubMed

    Miller, C W; Shafik, T M

    1974-01-01

    The insecticide propoxur was applied as 2 non-overlapping bands approximately 1 m wide to the interior of houses in El Salvador once every 35 days for a period of 9 months. Air samples were collected from the interior of the houses once every seventh day during the entire period. In the study area, air temperatures remain relatively constant, while rainfall varies seasonally. It was found that volatilization of propoxur, as determined by the amounts detectable in air, represented release of the chemical from the treated surface and that the volatilization process was most influenced by the amount of moisture present in the air. Higher air concentrations of propoxur occurred during periods of high relative humidity than in periods of low relative humidity. The principles involved in this process and its bearing on the value of propoxur in malaria control programmes are discussed.

  12. Effect of an ozone-generating air-purifying device on reducing concentrations of formaldehyde in air

    SciTech Connect

    Esswein, E.J.; Boeniger, M.F.

    1994-02-01

    Formaldehyde, an air contaminant found in many indoor air investigations, poses distinct occupational exposure hazards in certain job categories (e.g., mortuary science) but is also of concern when found or suspected in office buildings and homes. A variety of air-purifying devices (APDs) are currently available or marketed for application to reduce or remove concentrations of a variety of indoor air pollutants through the use of ozone as a chemical oxidant. An investigation was conducted to determine if concentrations of formaldehyde similar to those found in industrial hygiene evaluations of funeral homes could be reduced with the use of an ozone-generating APD. An ozone-generating APD was placed in an exposure chamber and formaldehyde-containing embalming solution was allowed to evaporate naturally, creating peak and mean chamber concentrations of 2.5 and 1.3 ppm, respectively. Continuous-reading instruments were used to sample for formaldehyde and ozone. Active sampling methods were also used to sample simultaneously for formaldehyde and a possible reactant product, formic acid. Triplicate measurements were made in each of three evaluations: formaldehyde alone, ozone alone, and formaldehyde and ozone combined. Concentrations of formaldehyde were virtually identical with and without 0.5 ppm ozone. No reduction in formaldehyde concentration was found during a 90-minute evaluation using ozone at this concentration with peak and average concentrations of approximately 2.5 and 1.3 ppm formaldehyde, respectively. The results of this investigation suggest that the use of ozone is ineffective in reducing concentrations of formaldehyde. Because ozone has demonstrated health hazards, and is a regulated air contaminant in both the occupational and ambient environment, the use of ozone as an air purification agent in indoor air does not seem warranted. 25 refs., 5 figs., 4 tabs.

  13. Reference values for indoor air pollutant concentrations in new, residential buildings in Finland

    NASA Astrophysics Data System (ADS)

    Järnström, H.; Saarela, K.; Kalliokoski, P.; Pasanen, A.-L.

    Eight buildings, representing the present construction practice in Finland, were investigated to create numeric reference data for indoor air quality (IAQ) in new residential buildings. Low-emitting materials according to the "Finnish Classification of Building Materials" were used in all the buildings. The airborne volatile organic compounds (VOCs), formaldehyde, and ammonia concentrations as well as temperature, relative humidity, and the air exchange rate were determined in the newly finished buildings and after 6 and 12 months. Target values for the indoor air concentrations were not generally reached in newly finished buildings. The lowest concentration levels were measured in buildings with mechanical supply and exhaust air systems. Formaldehyde concentrations fulfilled best the target values. The TVOC concentration usually reached the S2/S3-class values within 6 months. However, the ammonia concentration remained above the S3 limit during the whole first year. The concentrations of ammonia and formaldehyde showed seasonal variations, i.e., higher concentrations were measured in summer. The concentrations of individual VOCs generally decreased most strongly during the first 6 months and the final mean concentration levels were generally less than 15 μg m -3. As the occupancy period got longer, the VOCs originating from the construction phase were increasingly replaced by new ones. Reference values based on means and on 95 percentiles are presented to facilitate interpretation of the results of measurements done to ensure that proper construction practices have been applied or to investigate IAQ problems.

  14. Spectra of concentration of air pollution for turbulent convection

    SciTech Connect

    Patel, S.R.

    1996-12-31

    Very recently the study of formation and destruction of photochemical smog is increasing at both small and large scale. Also the transport of chemical species through the Planetary Boundary Layer (PBL) of the atmosphere is a key of the global change problem and will have to be parameterized more reliably than in the past. Further, in the air pollution modeling, the usual practice of neglecting the concentration correlation in the atmospheric photochemical reaction has recently been recognized as a source of serious error. So, it is important to study the various aspects of the concentration fluctuations (of air pollution) with chemical reaction. A model of the spectrum of concentration of air pollution with chemical reaction has been developed using the models of Hill and Hill and Clifford. The results obtained are applicable for arbitrary Schmidt number. Further, for the case of pure mixing (without chemical reaction) and the concentration replaced by temperature, the form of the spectra obtained here reduces to the form obtained by Hill and Clifford. This study also shows that, in the case of pure mixing, the concentration decays in a natural manner, but if the concentration selected is that of the chemical reactant, then the effect is that the dispersion of the concentration is much more rapid.

  15. An integrated Bayesian model for estimating the long-term health effects of air pollution by fusing modelled and measured pollution data: A case study of nitrogen dioxide concentrations in Scotland.

    PubMed

    Huang, Guowen; Lee, Duncan; Scott, Marian

    2015-01-01

    The long-term health effects of air pollution can be estimated using a spatio-temporal ecological study, where the disease data are counts of hospital admissions from populations in small areal units at yearly intervals. Spatially representative pollution concentrations for each areal unit are typically estimated by applying Kriging to data from a sparse monitoring network, or by computing averages over grid level concentrations from an atmospheric dispersion model. We propose a novel fusion model for estimating spatially aggregated pollution concentrations using both the modelled and monitored data, and relate these concentrations to respiratory disease in a new study in Scotland between 2007 and 2011. PMID:26530824

  16. An integrated Bayesian model for estimating the long-term health effects of air pollution by fusing modelled and measured pollution data: A case study of nitrogen dioxide concentrations in Scotland.

    PubMed

    Huang, Guowen; Lee, Duncan; Scott, Marian

    2015-01-01

    The long-term health effects of air pollution can be estimated using a spatio-temporal ecological study, where the disease data are counts of hospital admissions from populations in small areal units at yearly intervals. Spatially representative pollution concentrations for each areal unit are typically estimated by applying Kriging to data from a sparse monitoring network, or by computing averages over grid level concentrations from an atmospheric dispersion model. We propose a novel fusion model for estimating spatially aggregated pollution concentrations using both the modelled and monitored data, and relate these concentrations to respiratory disease in a new study in Scotland between 2007 and 2011.

  17. COMPARISON OF MOLD CONCENTRATIONS IN INDOOR AND OUTDOOR AIR SAMPLED SIMULTANEOUSLY AND THEN QUANTIFIED BY MSQPCR

    EPA Science Inventory

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of the 36 mold species in indoor and outdoor air samples that were taken simultaneously for 48 hours in and around 17 homes in Cincinnati, Ohio. The total spore concentrations of 353 per m3...

  18. Temperature and concentration transients in the aluminum-air battery

    SciTech Connect

    Homsy, R.V.

    1981-08-26

    Coupled conservation equations of heat and mass transfer are solved, that predict temperature and concentration of the electrolyte of an aluminum-air battery system upon start-up and shutdown. Results of recent laboratory studies investigating the crystallization kinetics and solubility of the caustic-aluminate electrolyte system are used in the predictions. Temperature and concentration start-up transients are short, while during standby conditions, temperature increases to a maximum and decreases slowly.

  19. Electron concentration distribution in a glow discharge in air flow

    NASA Astrophysics Data System (ADS)

    Mukhamedzianov, R. B.; Gaisin, F. M.; Sabitov, R. A.

    1989-04-01

    Electron concentration distributions in a glow discharge in longitudinal and vortex air flows are determined from the attenuation of the electromagnetic wave passing through the plasma using microwave probes. An analysis of the distribution curves obtained indicates that electron concentration decreases in the direction of the anode. This can be explained by charge diffusion toward the chamber walls and electron recombination and sticking within the discharge.

  20. Air Quality Measurements for Science and Policy

    EPA Science Inventory

    Air quality measurements and the methods used to conduct them are vital to advancing our knowledge of the source-to-receptor-to-health effects continuum1-3. This information then forms the basis for evaluating and managing air quality to protect human health and welfa...

  1. Measurement of Air Pollutants in the Troposphere

    ERIC Educational Resources Information Center

    Clemitshaw, Kevin C.

    2011-01-01

    This article describes the principles, applications and performances of methods to measure gas-phase air pollutants that either utilise passive or active sampling with subsequent laboratory analysis or involve automated "in situ" sampling and analysis. It focuses on air pollutants that have adverse impacts on human health (nitrogen dioxide, carbon…

  2. Auditing and assessing air quality in concentrated feeding operations

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The potential adverse effects of concentrated animal feeding operations (CAFO) on the environment are a growing concern. The air quality issues of most concerns to CAFO vary, but generally include ammonia, hydrogen sulfide, particulate matter (PM), volatile organic compounds (VOC), green house gase...

  3. Measuring Air Density in the Introductory Lab

    NASA Astrophysics Data System (ADS)

    Calzà, G.; Gratton, L. M.; López-Arias, T.; Oss, S.

    2010-03-01

    The measurement of the mass, or the density, of air can easily be done with very simple materials and offers many interesting phenomena for discussion—buoyancy and its effects being the most obvious but not the only one. Many interesting considerations can be done regarding the behavior of gases, the effect of the external conditions in the measurement, and the reason for the choice of the procedure, among others. One of the most widespread approaches makes use of rubber balloons. Such an approach can be misleading if attention is not paid to the effect of the buoyant force on the balloon, exerted by the surrounding air. Air is weightless in an environment full of it. While this fact can usually be neglected in daily, nontechnical weight measurements, it is not the case when we are interested in the weight of air itself. A sketch such as the one depicted in Fig. 1 is often presented in elementary science textbooks, as a demonstration that air has weight. A search of the Internet will reveal that this misleading approach is often presented as the simplest one for this kind of measurement at an elementary level and represents one among other common misconceptions that can be found in K-6 science textbooks as discussed, for instance, in Ref. 2. For a more detailed description of the flaws inherent to the measurement of air's weight with a rubber balloon, see Ref. 3. In this paper we will describe two procedures to measure the density of air: weighing a PET bottle and a vacuum rigid container. There are other interesting ways to estimate the weight of air; see, for instance, the experiment of Zhu and Se-yuen using carbon dioxide and Archimedes' principle.4 We emphasize the experimental implications and the physical reasons for the accuracy and conceptual correctness of each method. It is important not to undervalue the importance of both simplicity and reliability for any experimental measurement made in a didactic context.

  4. Measurement of toxic and related air pollutants

    SciTech Connect

    Jayanty, R.K.M.; Gay, B.W. Jr.

    1990-12-01

    A joint conference for the fifth straight year cosponsored by the Air and Waste Management Association's EM-3, EM-4, and ITF-2 technical committees, and the Atmospheric Research and Exposure Assessment Laboratory (AREAL) of the US Environmental Protection Agency, was held in Raleigh, North Carolina, May 1-4, 1990. The technical program consisted of 187 presentations, held in 20 technical sessions, on recent advances in the measurement and monitoring of toxic and related pollutants found in ambient and source atmospheres. Covering a wide range of measurement topics and supported by 66 exhibitors of instrumentation and consulting services, the symposium was attended by more than 850 professionals from the US and other countries. This overview highlights a selection of the technical presentations. A synopsis of the keynote address to the symposium is also included. Presentations include: (1) radon, (2) atmospheric chemistry and fate of toxic pollutants, (3) supercritical fluid extraction, (4) acidic deposition, (5) determination of polar and volatile organic pollutants in ambient air, (6) Delaware Superfund innovative technology evaluation (SITE) study, (7) mobile sources emissions characterization, (8) Superfund site air monitoring, (9) exposure assessment, (10) chemometrics and environmental data analysis, (11) nicotine in environmental tobacco smoke, (12) source monitoring, (13) effects of air toxics on plants, (14) measurement of volatile organic pollutants, (15) general, (16) air pollution dispersion modeling, (17) measurement of hazardous waste emissions, (18) measurement of indoor toxic air contaminants, and (19) environmental quality assurance.

  5. The active titration method for measuring local hydroxyl radical concentration

    NASA Technical Reports Server (NTRS)

    Sprengnether, Michele; Prinn, Ronald G.

    1994-01-01

    We are developing a method for measuring ambient OH by monitoring its rate of reaction with a chemical species. Our technique involves the local, instantaneous release of a mixture of saturated cyclic hydrocarbons (titrants) and perfluorocarbons (dispersants). These species must not normally be present in ambient air above the part per trillion concentration. We then track the mixture downwind using a real-time portable ECD tracer instrument. We collect air samples in canisters every few minutes for roughly one hour. We then return to the laboratory and analyze our air samples to determine the ratios of the titrant to dispersant concentrations. The trends in these ratios give us the ambient OH concentration from the relation: dlnR/dt = -k(OH). A successful measurement of OH requires that the trends in these ratios be measureable. We must not perturb ambient OH concentrations. The titrant to dispersant ratio must be spatially invariant. Finally, heterogeneous reactions of our titrant and dispersant species must be negligible relative to the titrant reaction with OH. We have conducted laboratory studies of our ability to measure the titrant to dispersant ratios as a function of concentration down to the few part per trillion concentration. We have subsequently used these results in a gaussian puff model to estimate our expected uncertainty in a field measurement of OH. Our results indicate that under a range of atmospheric conditions we expect to be able to measure OH with a sensitivity of 3x10(exp 5) cm(exp -3). In our most optimistic scenarios, we obtain a sensitivity of 1x10(exp 5) cm(exp -3). These sensitivity values reflect our anticipated ability to measure the ratio trends. However, because we are also using a rate constant to obtain our (OH) from this ratio trend, our accuracy cannot be better than that of the rate constant, which we expect to be about 20 percent.

  6. Air volume measurement of 'Braeburn' apple fruit.

    PubMed

    Drazeta, Lazar; Lang, Alexander; Hall, Alistair J; Volz, Richard K; Jameson, Paula E

    2004-05-01

    The radial disposition of air in the flesh of fruit of Malus domestica Borkh., cv 'Braeburn' was investigated using a gravimetric technique based on Archimedes' principle. Intercellular air volume was measured by weighing a small tissue sample under water before and after vacuum infiltration to remove the air. In a separate procedure, the volume of the same sample was measured by recording the buoyant upthrust experienced by it when fully immersed in water. The method underestimates tissue air volume due to a slight invasion of the intercellular air spaces around the edges of the sample when it is immersed in water. To correct for this error, an adjustment factor was made based upon an analysis of a series of measurements of air volume in samples of different dimensions. In 'Braeburn' there is a gradient of declining air content from just beneath the skin to the centre of the fruit with a sharp discontinuity at the core line. Cell shape and cell packing were observed in the surface layers of freshly excised and stained flesh samples using a dissecting microscope coupled to a video camera and a PC running proprietary software. Tissue organization changed with distance below the skin. It is speculated that reduced internal gas movement, due to the tightly packed tissue of 'Braeburn' and to the potential diffusion barrier at the core line between the cortex and the pith, may increase susceptibility of the flesh to disorders associated with tissue browning and breakdown. PMID:15047764

  7. Measuring surfactant concentration in plating solutions

    DOEpatents

    Bonivert, William D.; Farmer, Joseph C.; Hachman, John T.

    1989-01-01

    An arrangement for measuring the concentration of surfactants in a electrolyte containing metal ions includes applying a DC bias voltage and a modulated voltage to a counter electrode. The phase angle between the modulated voltage and the current response to the modulated voltage at a working electrode is correlated to the surfactant concentration.

  8. Predicting indoor pollutant concentrations, and applications to air quality management

    SciTech Connect

    Lorenzetti, David M.

    2002-10-01

    Because most people spend more than 90% of their time indoors, predicting exposure to airborne pollutants requires models that incorporate the effect of buildings. Buildings affect the exposure of their occupants in a number of ways, both by design (for example, filters in ventilation systems remove particles) and incidentally (for example, sorption on walls can reduce peak concentrations, but prolong exposure to semivolatile organic compounds). Furthermore, building materials and occupant activities can generate pollutants. Indoor air quality depends not only on outdoor air quality, but also on the design, maintenance, and use of the building. For example, ''sick building'' symptoms such as respiratory problems and headaches have been related to the presence of air-conditioning systems, to carpeting, to low ventilation rates, and to high occupant density (1). The physical processes of interest apply even in simple structures such as homes. Indoor air quality models simulate the processes, such as ventilation and filtration, that control pollutant concentrations in a building. Section 2 describes the modeling approach, and the important transport processes in buildings. Because advection usually dominates among the transport processes, Sections 3 and 4 describe methods for predicting airflows. The concluding section summarizes the application of these models.

  9. Trend and climate signals in seasonal air concentration of organochlorine pesticides over the Great Lakes

    NASA Astrophysics Data System (ADS)

    Gao, Hong; Ma, Jianmin; Cao, Zuohao; Dove, Alice; Zhang, Lisheng

    2010-08-01

    Following worldwide bans or restrictions, the atmospheric level of many organochlorine pesticides (OCPs) over the Great Lakes exhibited a decreasing trend since the 1980s in various environmental compartments. Atmospheric conditions also influence variation and trend of OCPs. In the present study a nonparametric Mann-Kendall test with an additional process to remove the effect of temporal (serial) correlation was used to detect the temporal trend of OCPs in the atmosphere over the Great Lakes region and to examine the statistical significance of the trends. Using extended time series of measured air concentrations over the Great Lakes region from the Integrated Atmospheric Deposition Network, this study also revisits relationships between seasonal mean air concentration of OCPs and major climate variabilities in the Northern Hemisphere. To effectively extract climate signals from the temporal trend of air concentrations, we detrended air concentrations through removing their linear trend, which is driven largely by their respective half-lives in the atmosphere. The interannual variations of the extended time series show a good association with interannual climate variability, notably, the North Atlantic Oscillation (NAO) and the El Niño-Southern Oscillation. This study demonstrates that the stronger climate signals can be extracted from the detrended time series of air concentrations of some legacy OCPs. The detrended concentration time series also help to interpret, in addition to the connection with interannual variation of the NAO, the links between atmospheric concentrations of OCPs and decadal or interdecadal climate change.

  10. Cyclic Concentration Measurements for Characterizing Pulsating Flow

    SciTech Connect

    Bamberger, Judith A.

    2013-07-07

    Slurry mixed in vessels via pulse jet mixers has a periodic, rather than steady, concentration profile. Measurements of local concentration taken at the center of the tank at a range of elevations within the mixed region were analyzed to obtain a greater understanding of how the periodic pulse jet mixing cycle affects the local concentration. Data were obtained at the critical suspension velocity, when all solids are suspended at the end of the pulse. The data at a range of solids loadings are analyzed to observe the effect of solids concentration during the suspension and settling portions of the mixing cycle.

  11. Validity of the Kusnetz method for measuring radon progeny concentration

    SciTech Connect

    Duport, P.

    1998-12-31

    The standard Kusnetz and Rolle methods currently used to measure the concentration of potential alpha energy due to the presence of radon progeny were designed at a time when ventilation conditions were very different than in current mines. This report reviews those methods and evaluated whether they are still reliable when the residency time of air underground is very short compared to the half-life of short-lived radon progeny, and in particular, under the new ventilation conditions that exist in Saskatchewan uranium mines. The uncertainty in measurements of potential alpha energy concentration is evaluated using Monte Carlo simulation.

  12. Measurement of dust concentration based on VBAI

    NASA Astrophysics Data System (ADS)

    Fu, You; Wang, Ninghui

    2013-03-01

    There are almost no economic and management solutions in automated measurement of dust concentration of magnesium oxide smelting electric arc furnace mouth. Nearly a thousand degrees of heat and the strong magnetic fields created by high-current Constitutes a serious interference with the sensor. This makes close-contact measurement method becomes almost impossible. To solve the above problem, this paper proposes a measurement scheme based on VBAI (Vision Builder for Automated Inspection, a software developed by National Instruments) to calculate the dust concentration. It uses visual analysis of the means to calculate the number of dust particles per unit volume of. And then it calculates the dust concentration. Though the analysis of the actual photo of the smelting site, the relative dust concentration in the mouth of the furnace is calculate. This method will be applied to the precipitator 70 kW motor inverter control and has a high recognition rate and significant application prospects.

  13. Mobile Air Monitoring: Measuring Change in Air Quality in the City of Hamilton, 2005-2010

    ERIC Educational Resources Information Center

    Adams, Matthew D.; DeLuca, Patrick F.; Corr, Denis; Kanaroglou, Pavlos S.

    2012-01-01

    This paper examines the change in air pollutant concentrations between 2005 and 2010 occurring in the City of Hamilton, Ontario, Canada. After analysis of stationary air pollutant concentration data, we analyze mobile air pollutant concentration data. Air pollutants included in the analysis are CO, PM[subscript 2.5], SO[subscript 2], NO,…

  14. Effect of outside air ventilation rate on VOC concentrations and emissions in a call center

    SciTech Connect

    Hodgson, A.T.; Faulkner, D.; Sullivan, D.P.; DiBartolomeo, D.L.; Russell, M.L.; Fisk, W.J.

    2002-01-01

    A study of the relationship between outside air ventilation rate and concentrations of VOCs generated indoors was conducted in a call center. Ventilation rates were manipulated in the building's four air handling units (AHUs). Concentrations of VOCs in the AHU returns were measured on 7 days during a 13-week period. Indoor minus outdoor concentrations and emission factors were calculated. The emission factor data was subjected to principal component analysis to identify groups of co-varying compounds based on source type. One vector represented emissions of solvents from cleaning products. Another vector identified occupant sources. Direct relationships between ventilation rate and concentrations were not observed for most of the abundant VOCs. This result emphasizes the importance of source control measures for limiting VOC concentrations in buildings.

  15. Indoor air polychlorinated biphenyl concentrations in three communities along the Upper Hudson River, New York.

    PubMed

    Wilson, Lloyd R; Palmer, Patrick M; Belanger, Erin E; Cayo, Michael R; Durocher, Lorie A; Hwang, Syni-An A; Fitzgerald, Edward F

    2011-10-01

    Indoor air polychlorinated biphenyl (PCB) concentrations were measured in upstate New York as part of a nonoccupational exposure investigation. The adjacent study communities contain numerous sites of current and former PCB contamination, including two capacitor-manufacturing facilities. Indoor air PCB concentrations in the study area homes were not significantly different than in the comparison area homes. Total PCB concentrations in the study area homes ranged from 0.3 to 114.3 ng/m(3) (median 7.9). For the comparison area homes, concentrations ranged from 0.3 to 233.3 ng/m(3) (median 6.8). No correlations were found between PCB concentrations in indoor and outdoor air, with indoor concentrations generally 20 times higher than outdoor concentrations. Of the home characteristics cataloged, the presence of fluorescent lights was significantly associated with total PCB concentration in the study area only. The indoor PCB concentrations measured in this study are similar to those in other communities with known PCB-contaminated sites and similar to levels reported in other locations from the northeastern United States. PMID:21136249

  16. FMPS measurement of nanoparticle pollutant in office air

    NASA Astrophysics Data System (ADS)

    Yin, Zhaoqin; Lin, Jianzhong; Yu, Mingzhou

    2010-08-01

    Fast Mobility Particle Sizer (FMPS) is an electrical mobility instrument used to measure the nanoparticle number concentration and size distribution in an office environment. Actual measurements indicate the distributions of ultrafine particle number and size in office air are inhomogeneous in space. The nonaparticle size is bimodal and log-normally distribution in an office environment when only people activities are considered. The traffic pollutant in the outdoor including the automobile tail gas and the dust will change the particles size distribution and enhance the particle number concentration those of indoor air. It can also be seen from the results that the laser printer releases a large number of nanoparticles, especially around 80nm in diameter in the printing process. The laser printer may be the mainly ultrafine particle source in the office air.

  17. Measurement of formaldehyde in clean air

    SciTech Connect

    Neitzert, V.; Seiler, W.

    1981-01-01

    A method for the measurement of small amounts of formaldehyde in air has been developed. The method is based on the derivatization of HCHO with 2.4-Denetrophenylhydragine, forming 2.4-Dentrophylhydragine, measured with GC-ECD-technique. HCHO is preconcentrated using a cryogenic sampling technique. The detection limit is 0.05 ppbv for a sampling volume of 200 liter. The method has been applied for measurements in continental and marine air masses showing HCHO mixing ratios of 0.4--5.0 ppbv and 0.2--1.0 ppbv, respectively. HCHO mixing ratios show diurnal variations with maximum values during the early afternoon and minimum values during the early morning. In continental air, HCHO mixing ratios are positively correlated with CO and SO/sub 2/, indicating anthropogenic HCHO sources which are estimated to be 6--11 x 10/sup 12/g/year/sup -1/ on a global scale.

  18. Toward Localized In Vivo Biomarker Concentration Measurements

    PubMed Central

    Zhang, Xiaojuan; Reeves, Daniel; Shi, Yipeng; Gimi, Barjor; Nemani, Krishnamurthy V.; Perreard, Irina M.; Toraya-Brown, Seiko; Fiering, Steven; Weaver, John B.

    2015-01-01

    We know a great deal about the biochemistry of cells because they can be isolated and studied. The biochemistry of the much more complex in vivo environment is more difficult to study because the only ways to quantitate concentrations is to sacrifice the animal or biopsy the tissue. Either method disrupts the environment profoundly and neither method allows longitudinal studies on the same individual. Methods of measuring chemical concentrations in vivo are very valuable alternatives to sacrificing groups of animals. We are developing microscopic magnetic nanoparticle (mNP) probes to measure the concentration of a selected molecule in vivo. The mNPs are targeted to bind the selected molecule and the resulting reduction in rotational freedom can be quantified remotely using magnetic spectroscopy. The mNPs must be contained in micrometer sized porous shells to keep them from migrating and to protect them from clearance by the immune system. There are two key issues in the development of the probes. First, we demonstrate the ability to measure concentrations in the porous walled alginate probes both in phosphate buffered saline and in blood, which is an excellent surrogate for the complex and challenging in vivo environment. Second, sensitivity is critical because it allows microscopic probes to measure very small concentrations very far away. We report sensitivity measurements on recently introduced technology that has allowed us to improve the sensitivity by two orders of magnitude, a factor of 200 so far. PMID:26203196

  19. Measurement of particle concentrations in a dental office.

    PubMed

    Sotiriou, Maria; Ferguson, Stephen F; Davey, Mark; Wolfson, Jack M; Demokritou, Philip; Lawrence, Joy; Sax, Sonja N; Koutrakis, Petros

    2008-02-01

    Particles in a dental office can be generated by a number of instruments, such as air-turbine handpieces, low-speed handpieces, ultrasonic scalers, bicarbonate polishers, polishing cups, as well as drilling and air sprays inside the oral cavity. This study examined the generation of particles during dental drilling and measured particle size, mass, and trace elements. The air sampling techniques included both continuous and integrated methods. The following particle continuous measurements were taken every minute: (1) size-selective particle number concentration (Climet); (2) total particle number concentration (PTRAK), and; (3) particle mass concentration (DustTrak). Integrated particle samples were collected for about 5 h on each of five sampling days, using a PM(2.5) sampler (ChemComb) for elemental/organic carbon analysis, and a PM(10) sampler (Harvard Impactor) for mass and elemental analyses. There was strong evidence that these procedures result in particle concentrations above background. The dental procedures produced number concentrations of relatively small particles (<0.5 microm) that were much higher than concentrations produced for the relatively larger particles (>0.5 microm). Also, these dental procedures caused significant elevation above background of certain trace elements (measured by X-ray fluorescence) but did not cause any elevation of elemental carbon (measured by thermal optical reflectance). Dental drilling procedures aerosolize saliva and products of drilling, producing particles small enough to penetrate deep into the lungs. The potential health impacts of the exposure of dental personnel to such particles need to be evaluated. Increased ventilation and personal breathing protection could be used to minimize harmful effects.

  20. Modeling Airborne Beryllium Concentrations From Open Air Dynamic Testing

    NASA Astrophysics Data System (ADS)

    Becker, N. M.

    2003-12-01

    A heightened awareness of airborne beryllium contamination from industrial activities was reestablished during the late 1980's and early 1990's when it became recognized that Chronic Beryllium Disease (CBD) had not been eradicated, and that the Occupational Health and Safety Administration standards for occupational air exposure to beryllium may not be sufficiently protective. This was in response to the observed CBD increase in multiple industrial settings where beryllium was manufactured and/or machined, thus producing beryllium particulates which are then available for redistribution by airborne transport. Sampling and modeling design activities were expanded at Los Alamos National Laboratory in New Mexico to evaluate potential airborne beryllium exposure to workers who might be exposed during dynamic testing activities associated with nuclear weapons Stockpile Stewardship. Herein is presented the results of multiple types of collected air measurements that were designed to characterize the production and dispersion of beryllium used in components whose performance is evaluated during high explosive detonation at open air firing sites. Data from fallout, high volume air, medium volume air, adhesive film, particle size impactor, and fine-particulate counting techniques will be presented, integrated, and applied in dispersion modeling to assess potential onsite and offsite personal exposures resulting from dynamic testing activities involving beryllium.

  1. An assessment of ozone concentrations within and near the Lake Tahoe Air Basin

    NASA Astrophysics Data System (ADS)

    Dolislager, Leon J.; VanCuren, Richard; Pederson, James R.; Lashgari, Ash; McCauley, Eileen

    2012-01-01

    The Lake Tahoe Atmospheric Deposition Study (LTADS) was conducted by the Air Resources Board of the State of California (CARB) primarily to generate refined estimates of the atmospheric deposition of nitrogen, phosphorous, and particulate matter directly to Lake Tahoe, which straddles the border between the states of California and Nevada near Reno, Nevada. The enhanced air quality monitoring during LTADS also included ozone measurements, which yielded additional insights into atmospheric processes and the role of transport in determining ozone concentrations within the Lake Tahoe Air Basin. The Lake Tahoe Air Basin is located generally downwind of air basins with major emissions of ozone precursors (e.g., VOCs, NOx), capable of generating significant ozone concentrations. Furthermore, vegetation on the western slope of the Sierra Nevada contribute biogenic organic compounds to the air mass. Ozone concentrations within the Tahoe Basin infrequently exceed the local 1-h threshold set to protect forest health (0.08 ppm) and the California 8-h ambient air quality standard (0.070 ppm). A concern then is the potential contribution of regional emission sources to the ozone concentrations observed in the Tahoe Basin. The ozone data collected during LTADS helped to better characterize the relative contribution of local and regional pollution sources to ozone air quality within the Tahoe Basin. The data indicate potential 1- or 2-day intact transport on rare occasions but generally the mixing of the atmosphere over the Sierra Nevada disperses the anthropogenic ozone throughout the boundary layer, which is generally more than a kilometer or two deep during the day. The data analysis indicates that emissions from upwind air basins add to the atmospheric burden of ozone concentrations, raising the regional concentrations in the Sierra Nevada. Given the large background and upwind enhancements relative to the ambient air quality standards, the local contribution does not need to

  2. Modeling indoor air concentrations near emission sources in imperfectly mixed rooms.

    PubMed

    Furtaw, E J; Pandian, M D; Nelson, D R; Behar, J V

    1996-09-01

    Assessments of exposure to indoor air pollutants usually employ spatially well-mixed models which assume homogeneous concentrations throughout a building or room. However, practical experience and experimental data indicate that concentrations are not uniform in rooms containing point sources of emissions; concentrations tend to be greater in close proximity to the source than they are further from it. This phenomenon could account for the observation that "personal air" monitors frequently yield higher concentrations than nearby microenvironmental monitors (i.e., the so-called "personal cloud" effect). In this project, we systematically studied the concentrations of a tracer gas at various distances from its emission source in a controlled-environment, room-size chamber under a variety of ventilation conditions. Measured concentrations in the proximity of the source deviated significantly above the predictions of a conventional well-mixed single-compartment mass balance model. The deviation was found to be a function of distance from the source and total room air flow rate. At typical air flow rates, the average concentration at arm's length (approximately 0.4 meters) from the source exceeds the theoretical well-mixed concentration by a ratio of about 2:1. However, this ratio is not constant; the monitored concentration appears to vary randomly from near the theoretical value to several times above it. Concentration data were fitted to a two-compartment model with the source located in a small virtual compartment within the room compartment. These two compartments were linked with a stochastic air transfer rate parameter. The resulting model provides a more realistic simulation of exposure concentrations than does the well-mixed model for assessing exposure to emissions from active sources. Parameter values are presented for using the enhanced model in a variety of typical situations. PMID:8925388

  3. The effects of forced air flow and oxygen concentration on flammability, smoke density, and pyrolytic toxicity

    NASA Technical Reports Server (NTRS)

    Sauers, D. G.

    1976-01-01

    The question is posed whether forced air flow should be incorporated into flammability tests as a relevant variable. A test apparatus is described which permits tests to be conducted on small test specimens in a forced flow which is (continuously) variable over flow velocities from zero to 300 feet per minute (1.52 m/s). The effects of air-flow rate and oxygen concentration on flame propagation rate, maximum smoke density, and pyrolytic product toxicity were measured for a single material and were statistically evaluated. Regression analysis was used to graph the resulting relationships. It is concluded that air velocity is an important variable for laboratory flammability testing.

  4. Low cost electrochemical sensor module for measurement of gas concentration

    NASA Astrophysics Data System (ADS)

    Jasinski, Grzegorz; Strzelczyk, Anna; Koscinski, Piotr

    2016-01-01

    This paper describes a low cost electrochemical sensor module for gas concentration measurement. A module is universal and can be used for many types of electrochemical gas sensors. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP91000 is used. The proposed equipment will be used as a component of electronic nose system employed for classifying and distinguishing different levels of air contamination.

  5. Influence of indoor air conditions on radon concentration in a detached house.

    PubMed

    Akbari, Keramatollah; Mahmoudi, Jafar; Ghanbari, Mahdi

    2013-02-01

    Radon is released from soil and building materials and can accumulate in residential buildings. Breathing radon and radon progeny for extended periods hazardous to health and can lead to lung cancer. Indoor air conditions and ventilation systems strongly influence indoor radon concentrations. This paper focuses on effects of air change rate, indoor temperature and relative humidity on indoor radon concentrations in a one family detached house in Stockholm, Sweden. In this study a heat recovery ventilation system unit was used to control the ventilation rate and a continuous radon monitor (CRM) was used to measure radon levels. FLUENT, a computational fluid dynamics (CFD) software package was used to simulate radon entry into the building and air change rate, indoor temperature and relative humidity effects using a numerical approach. The results from analytical solution, measurements and numerical simulations showed that air change rate, indoor temperature and moisture had significant effects on indoor radon concentration. Increasing air change rate reduces radon level and for a specific air change rate (in this work Ach = 0.5) there was a range of temperature and relative humidity that minimized radon levels. In this case study minimum radon levels were obtained at temperatures between 20 and 22 °C and a relative humidity of 50-60%.

  6. Influence of indoor air conditions on radon concentration in a detached house.

    PubMed

    Akbari, Keramatollah; Mahmoudi, Jafar; Ghanbari, Mahdi

    2013-02-01

    Radon is released from soil and building materials and can accumulate in residential buildings. Breathing radon and radon progeny for extended periods hazardous to health and can lead to lung cancer. Indoor air conditions and ventilation systems strongly influence indoor radon concentrations. This paper focuses on effects of air change rate, indoor temperature and relative humidity on indoor radon concentrations in a one family detached house in Stockholm, Sweden. In this study a heat recovery ventilation system unit was used to control the ventilation rate and a continuous radon monitor (CRM) was used to measure radon levels. FLUENT, a computational fluid dynamics (CFD) software package was used to simulate radon entry into the building and air change rate, indoor temperature and relative humidity effects using a numerical approach. The results from analytical solution, measurements and numerical simulations showed that air change rate, indoor temperature and moisture had significant effects on indoor radon concentration. Increasing air change rate reduces radon level and for a specific air change rate (in this work Ach = 0.5) there was a range of temperature and relative humidity that minimized radon levels. In this case study minimum radon levels were obtained at temperatures between 20 and 22 °C and a relative humidity of 50-60%. PMID:23159846

  7. Measurement of oxygen transfer from air into organic solvents

    PubMed Central

    Ramesh, Hemalata; Hobisch, Mathias; Borisov, Sergey; Klimant, Ingo; Krühne, Ulrich; Woodley, John M

    2015-01-01

    Abstract BACKGROUND The use of non‐aqueous organic media is becoming increasingly important in many biotechnological applications in order to achieve process intensification. Such media can be used, for example, to directly extract poorly water‐soluble toxic products from fermentations. Likewise many biological reactions require the supply of oxygen, most normally from air. However, reliable online measurements of oxygen concentration in organic solvents (and hence oxygen transfer rates from air to the solvent) has to date proven impossible due to limitations in the current analytical methods. RESULTS For the first time, online oxygen measurements in non‐aqueous media using a novel optical sensor are demonstrated. The sensor was used to measure oxygen concentration in various organic solvents including toluene, THF, isooctane, DMF, heptane and hexane (which have all been shown suitable for several biological applications). Subsequently, the oxygen transfer rates from air into these organic solvents were measured. CONCLUSION The measurement of oxygen transfer rates from air into organic solvents using the dynamic method was established using the solvent resistant optical sensor. The feasibility of online oxygen measurements in organic solvents has also been demonstrated, paving the way for new opportunities in process control. © 2015 The Authors. Journal of Chemical Technology & Biotechnology published by JohnWiley & Sons Ltd on behalf of Society of Chemical Industry.

  8. Variations of 210Pb concentrations in surface air at Thessaloniki, Greece (40°N)

    NASA Astrophysics Data System (ADS)

    Ioannidou, A.; Kotsopoulou, E.; Karanatsiou, A.; Papastefanou, C.

    2012-04-01

    Atmospheric concentrations of 210Pb were measured over the year 2009 in ground level air at Thessaloniki, Northern Greece (40°62' N, 22°95'E). The mean activity concentrations of 210Pb in surface air have been found to be 671 ± 213 μBq m-3. The highest values of monthly atmospheric concentrations of 210Pb were observed in the autumn and the lowest in the spring period. The higher values of 210Pb during autumn were attributed to frequent inversion conditions of the surface layers, resulting in an enrichment of radon and its decay products in surface air. The lower values during the winter months might be due to the low emanation of radon from the frozen or snow-covered soil. The minima of 210Pb concentrations during spring might reflect on higher washout during this period, which results in less emanation of radon from saturated with water soil, resulting in less production of 210Pb near ground-level air. The relative high values during summer are probably due to the higher 222Rn exhalation from the ground and due to the higher air mixing within the troposphere, which has as a result to carry down to the surface layer 210Pb whose origin is older air masses which entered into the free troposphere.

  9. A PRINCIPAL COMPONENT ANALYSIS OF THE CLEAN AIR STATUS AND TRENDS NETWORK (CASTNET) AIR CONCENTRATION DATA

    EPA Science Inventory

    The spatial and temporal variability of ambient air concentrations of SO2, SO42-, NO3, HNO3, and NH4+ obtained from EPA's CASTNet was examined using an objective, statistically based technique...

  10. Measuring protein concentration with entangled photons

    NASA Astrophysics Data System (ADS)

    Crespi, Andrea; Lobino, Mirko; Matthews, Jonathan C. F.; Politi, Alberto; Neal, Chris R.; Ramponi, Roberta; Osellame, Roberto; O'Brien, Jeremy L.

    2012-06-01

    Optical interferometry is amongst the most sensitive techniques for precision measurement. By increasing the light intensity, a more precise measurement can usually be made. However, if the sample is light sensitive entangled states can achieve the same precision with less exposure. This concept has been demonstrated in measurements of known optical components. Here, we use two-photon entangled states to measure the concentration of a blood protein in an aqueous buffer solution. We use an opto-fluidic device that couples a waveguide interferometer with a microfluidic channel. These results point the way to practical applications of quantum metrology to light-sensitive samples.

  11. Effects of the Deregulation on the Concentration of the Brazilian Air Transportation Industry

    NASA Technical Reports Server (NTRS)

    Guterres, Marcelo Xavier; Muller, Carlos

    2003-01-01

    This paper addresses the effects of the deregulation of the Brazilian air transportation industry in terms of the concentration of the market. We will show some metrics that are commonly used to study the concentration of the industry. This paper uses the Herfindhal- Hirschman Index. This index tends to zero in the competitive scenario, with a large number of small firms, and to one in case of a monopolistic scenario. The paper analyses the dynamics of the concentration of the Brazilian domestic air transportation market, in order to evaluate the effects of deregulation. We conclude that the Brazilian market presents oligopoly characteristics and aspects in its current structure that maintain the market concentrated in spite of the Deregulation measures adopted by the aeronautical authority. Keywords: Herfindhal-Hirschman Index, concentration, Deregulation

  12. Measuring Air Density in the Introductory Lab

    ERIC Educational Resources Information Center

    Calza, G.; Gratton, L. M.; Lopez-Arias, T.; Oss, S.

    2010-01-01

    The measurement of the mass, or the density, of air can easily be done with very simple materials and offers many interesting phenomena for discussion--buoyancy and its effects being the most obvious but not the only one. Many interesting considerations can be done regarding the behavior of gases, the effect of the external conditions in the…

  13. Measure Guideline: Guide to Attic Air Sealing

    SciTech Connect

    Lstiburek, J.

    2014-09-01

    The Guide to Attic Air Sealing was completed in 2010 and although not in the standard Measure Guideline format, is intended to be a Measure Guideline on Attic Air Sealing. The guide was reviewed during two industry stakeholders meetings held on December 18th, 2009 and January 15th, 2010, and modified based on the comments received. Please do not make comments on the Building America format of this document. The purpose of the Guide to Attic Air Sealing is to provide information and recommendations for the preparation work necessary prior to adding attic insulation. Even though the purpose of this guide is to save energy - health, safety and durability should not be compromised by energy efficiency. Accordingly, combustion safety and ventilation for indoor air quality are addressed first. Durability and attic ventilation then follow. Finally, to maximize energy savings, air sealing is completed prior to insulating. The guide is intended for home remodelers, builders, insulation contractors, mechanical contractors, general contractors who have previously done remodeling and homeowners as a guide to the work that needs to be done.

  14. Identification and influence of spatial outliers in air quality measurements

    NASA Astrophysics Data System (ADS)

    O'Leary, B. F.; Lemke, L. D.

    2015-12-01

    The heterogeneous nature of urban air complicates the analysis of spatial and temporal variability in air quality measurements. Evaluation of potentially inaccurate measurements (i.e., outliers) poses particularly difficult challenges in extensive air quality datasets with multiple measurements distributed in time and space. This study investigated the identification and impact of outliers in measurements of NO­2, BTEX, PM2.5, and PM10 in the contiguous Detroit, Michigan, USA and Windsor, Ontario, Canada international airshed. Measurements were taken at 100 locations during September 2008 and June 2009 and modeled at a 300m by 300m scale resolution. The objective was to determine if outliers were present and, if so, to quantify the magnitude of their impact on modeled spatial pollution distributions. The study built upon previous investigations by the Geospatial Determinants of Health Outcomes Consortium that examined relationships between air pollutant distributions and asthma exacerbations in the Detroit and Windsor airshed. Four independent approaches were initially employed to identify potential outliers: boxplots, variogram clouds, difference maps, and the Local Moran's I statistic. Potential outliers were subsequently reevaluated for consistency among methods and individually assessed to select a final set of outliers. The impact of excluding individual outliers was subsequently determined by revising the spatially variable air pollution models and recalculating associations between air contaminant concentrations and asthma exacerbations in Detroit and Windsor in 2008. For the pollutants examined, revised associations revealed weaker correlations with spatial outliers removed. Nevertheless, the approach employed improves the model integrity by increasing our understanding of the spatial variability of air pollution in the built environment and providing additional insights into the association between acute asthma exacerbations and air pollution.

  15. LOW-CONCENTRATION NOX EMISSIONS MEASUREMENT

    EPA Science Inventory

    The paper gives results of a recent series of low-concentration nitrogen oxides (NOx) emission measurements, made by Midwest Research Institute (MRI) during U.S. EPA-sponsored Environmental Technology Verification (ETV) test of a NOx control system called Xonon (TM) Cool Combust...

  16. Measure Guideline: Guide to Attic Air Sealing

    SciTech Connect

    Lstiburek, Joseph

    2014-09-01

    The purpose of this measure guideline is to provide information and recommendations for the preparation work necessary prior to adding attic insulation. Even though the purpose of this guide is to save energy, health, safety, and durability should not be compromised by energy efficiency. Accordingly, combustion safety and ventilation for indoor air quality are addressed first. Durability and attic ventilation then follow. Finally, to maximize energy savings, air sealing is completed prior to insulating. The guide is intended for home remodelers, builders, insulation contractors, mechanical contractors, general contractors who have previously done remodeling and homeowners as a guide to the work that needs to be done.

  17. The Aeroflex: A Bicycle for Mobile Air Quality Measurements

    PubMed Central

    Elen, Bart; Peters, Jan; Van Poppel, Martine; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout

    2013-01-01

    Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification. PMID:23262484

  18. The Aeroflex: a bicycle for mobile air quality measurements.

    PubMed

    Elen, Bart; Peters, Jan; Poppel, Martine Van; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout

    2013-01-01

    Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification. 

  19. 40 CFR 91.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... with intake air other than the ambient air in the test cell (i.e., air which has been pumbed directly to the engine air intake system). For engines which use ambient test cell air for the engine intake... the humidity conditioning has taken place. (b) Unconditioned air supply. Humidity measurements...

  20. 40 CFR 90.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... engines which are supplied with intake air other than the ambient air in the test cell (i.e., air which has been pumped directly to the engine air intake system). For engines which use ambient test cell air for the engine intake air, the ambient test cell humidity measurement may be used. (a)...

  1. 40 CFR 91.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... with intake air other than the ambient air in the test cell (i.e., air which has been pumbed directly to the engine air intake system). For engines which use ambient test cell air for the engine intake... the humidity conditioning has taken place. (b) Unconditioned air supply. Humidity measurements...

  2. 40 CFR 90.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... engines which are supplied with intake air other than the ambient air in the test cell (i.e., air which has been pumped directly to the engine air intake system). For engines which use ambient test cell air for the engine intake air, the ambient test cell humidity measurement may be used. (a)...

  3. Indoor air-assessment: Indoor concentrations of environmental carcinogens

    SciTech Connect

    Gold, K.W.; Naugle, D.F.; Berry, M.A.

    1991-01-01

    In the report, indoor concentration data are presented for the following general categories of air pollutants: radon-222, environmental tobacco smoke (ETS), asbestos, gas phase organic compounds, formaldehyde, polycyclic aromatic hydrocarbons (PAH), pesticides, and inorganic compounds. These pollutants are either known or suspect carcinogens (i.e., radon-222, asbestos) or more complex mixtures or classes of compounds which contain known or suspect carcinogens. Concentration data for individual carcinogenic compounds in complex mixtures are usually far from complete. The data presented for complex mixtures often include compounds which are not carcinogenic or for which data are insufficient to evaluate carcinogenicity. Their inclusion is justified, however, by the possibility that further work may show them to be carcinogens, cocarcinogens, initiators or promotors, or that they may be employed as markers (e.g., nicotine, acrolein) for the estimation of exposure to complex mixtures.

  4. Air Pollution in China: Mapping of Concentrations and Sources

    PubMed Central

    Rohde, Robert A.; Muller, Richard A.

    2015-01-01

    China has recently made available hourly air pollution data from over 1500 sites, including airborne particulate matter (PM), SO2, NO2, and O3. We apply Kriging interpolation to four months of data to derive pollution maps for eastern China. Consistent with prior findings, the greatest pollution occurs in the east, but significant levels are widespread across northern and central China and are not limited to major cities or geologic basins. Sources of pollution are widespread, but are particularly intense in a northeast corridor that extends from near Shanghai to north of Beijing. During our analysis period, 92% of the population of China experienced >120 hours of unhealthy air (US EPA standard), and 38% experienced average concentrations that were unhealthy. China’s population-weighted average exposure to PM2.5 was 52 μg/m3. The observed air pollution is calculated to contribute to 1.6 million deaths/year in China [0.7–2.2 million deaths/year at 95% confidence], roughly 17% of all deaths in China. PMID:26291610

  5. Air Pollution in China: Mapping of Concentrations and Sources.

    PubMed

    Rohde, Robert A; Muller, Richard A

    2015-01-01

    China has recently made available hourly air pollution data from over 1500 sites, including airborne particulate matter (PM), SO2, NO2, and O3. We apply Kriging interpolation to four months of data to derive pollution maps for eastern China. Consistent with prior findings, the greatest pollution occurs in the east, but significant levels are widespread across northern and central China and are not limited to major cities or geologic basins. Sources of pollution are widespread, but are particularly intense in a northeast corridor that extends from near Shanghai to north of Beijing. During our analysis period, 92% of the population of China experienced >120 hours of unhealthy air (US EPA standard), and 38% experienced average concentrations that were unhealthy. China's population-weighted average exposure to PM2.5 was 52 μg/m3. The observed air pollution is calculated to contribute to 1.6 million deaths/year in China [0.7-2.2 million deaths/year at 95% confidence], roughly 17% of all deaths in China. PMID:26291610

  6. 40 CFR 91.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Intake air flow measurement... Procedures § 91.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure the air flow over the...

  7. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Air flow measurement specifications... Emission Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement method used must have a range large enough to accurately measure the air flow over the engine operating...

  8. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Air flow measurement specifications. 89... Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement method used must have a range large enough to accurately measure the air flow over the engine operating...

  9. 40 CFR 91.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Intake air flow measurement... Procedures § 91.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure the air flow over the...

  10. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Air flow measurement specifications... Emission Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement method used must have a range large enough to accurately measure the air flow over the engine operating...

  11. 40 CFR 91.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Intake air flow measurement... Procedures § 91.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure the air flow over the...

  12. 40 CFR 91.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Intake air flow measurement... Procedures § 91.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure the air flow over the...

  13. Modeling the Concentrations of On-Road Air Pollutants in Southern California

    PubMed Central

    Li, Lianfa; Wu, Jun; Hudda, Neelakshi; Sioutas, Constantinos; Fruin, Scott A.; Delfino, Ralph J.

    2014-01-01

    High concentrations of air pollutants on roadways, relative to ambient concentrations, contribute significantly to total personal exposure. Estimation of these exposures requires measurements or prediction of roadway concentrations. Our study develops, compares and evaluates linear regression and non-linear generalized additive models (GAMs) to estimate on-road concentrations of four key air pollutants, particle-bound polycyclic aromatic hydrocarbons (PB-PAH), particle number count (PNC), nitrogen oxides (NOx), and particulate matter with diameter <2.5 μm (PM2.5) using traffic, meteorology, and elevation variables. Critical predictors included wind speed and direction for all the pollutants, traffic-related variables for PB-PAH, PNC, and NOx, and air temperatures and relative humidity for PM2.5. GAMs explained 50%, 55%, 46%, and 71% of the variance for log or square-root transformed concentrations of PB-PAH, PNC, NOx, and PM2.5 respectively, an improvement of 5 to over 15% over the linear models. Accounting for temporal autocorrelation in the GAMs further improved the prediction, explaining 57-89% of the variance. We concluded that traffic and meteorological data are good predictors in estimating on-road traffic-related air pollutant concentrations and GAMs perform better for non-linear variables, such as meteorological parameters. PMID:23859442

  14. PAH Measurements in Air in the Athabasca Oil Sands Region.

    PubMed

    Hsu, Yu-Mei; Harner, Tom; Li, Henrik; Fellin, Phil

    2015-05-01

    Polycyclic aromatic hydrocarbon (PAH) measurements were conducted by Wood Buffalo Environmental Association (WBEA) at four community ambient Air quality Monitoring Stations (AMS) in the Athabasca Oil Sands Region (AOSR) in Northeastern Alberta, Canada. The 2012 and 2013 mean concentrations of a subset of the 22 PAH species were 9.5, 8.4, 8.8, and 32 ng m(-3) at AMS 1 (Fort McKay), AMS 6 (residential Fort McMurray), AMS 7 (downtown Fort McMurray), and AMS 14 (Anzac), respectively. The average PAH concentrations in Fort McKay and Fort McMurray were in the range of rural and semirural areas, but peak values reflect an industrial emission influence. At these stations, PAHs were generally associated with NO, NO2, PM2.5, and SO2, indicating the emissions were from the combustion sources such as industrial stacks, vehicles, residential heating, and forest fires, whereas the PAH concentrations at AMS 14 (∼35 km south of Fort McMurray) were more characteristic of urban areas with a unique pattern: eight of the lower molecular weight PAHs exhibited strong seasonality with higher levels during the warmer months. Enthalpies calculated from Clausius-Clapeyron plots for these eight PAHs suggest that atmospheric emissions were dominated by temperature-dependent processes such as volatilization at warm temperatures. These findings point to the potential importance of localized water-air and/or surface-air transfer on observed PAH concentrations in air.

  15. PAH Measurements in Air in the Athabasca Oil Sands Region.

    PubMed

    Hsu, Yu-Mei; Harner, Tom; Li, Henrik; Fellin, Phil

    2015-05-01

    Polycyclic aromatic hydrocarbon (PAH) measurements were conducted by Wood Buffalo Environmental Association (WBEA) at four community ambient Air quality Monitoring Stations (AMS) in the Athabasca Oil Sands Region (AOSR) in Northeastern Alberta, Canada. The 2012 and 2013 mean concentrations of a subset of the 22 PAH species were 9.5, 8.4, 8.8, and 32 ng m(-3) at AMS 1 (Fort McKay), AMS 6 (residential Fort McMurray), AMS 7 (downtown Fort McMurray), and AMS 14 (Anzac), respectively. The average PAH concentrations in Fort McKay and Fort McMurray were in the range of rural and semirural areas, but peak values reflect an industrial emission influence. At these stations, PAHs were generally associated with NO, NO2, PM2.5, and SO2, indicating the emissions were from the combustion sources such as industrial stacks, vehicles, residential heating, and forest fires, whereas the PAH concentrations at AMS 14 (∼35 km south of Fort McMurray) were more characteristic of urban areas with a unique pattern: eight of the lower molecular weight PAHs exhibited strong seasonality with higher levels during the warmer months. Enthalpies calculated from Clausius-Clapeyron plots for these eight PAHs suggest that atmospheric emissions were dominated by temperature-dependent processes such as volatilization at warm temperatures. These findings point to the potential importance of localized water-air and/or surface-air transfer on observed PAH concentrations in air. PMID:25844542

  16. Ozone concentration in leaf intercellular air spaces is close to zero

    SciTech Connect

    Laisk, A.; Moldau, H. ); Kull, O. )

    1989-07-01

    Transpiration and ozone uptake rates were measured simultaneously in sunflower leaves at different stomatal openings and various ozone concentrations. Ozone uptake rates were proportional to the ozone concentration up to 1500 nanoliters per liter. The leaf gas phase diffusion resistance (stomatal plus boundary layer) to water vapor was calculated and converted to the resistance to ozone multiplying it by the theoretical ratio of diffusion coefficients for water vapor and ozone in air (1.67). The ozone concentration in intercellular air spaces calculated from the ozone uptake rate and diffusion resistance to ozone scattered around zero. The ozone concentration in intercellular air spaces was measured directly bu supplying ozone to the leaf from one side and measuring the equilibrium concentration above the other side, and it was found to be zero. The total leaf resistance to ozone was proportional to the gas phase resistance to water vapor with a coefficient of 1.68. It is concluded that ozone enters the leaf by diffusion through the stomata, and is rapidly decomposed in cell walls and plasmalemma.

  17. Ozone concentration in leaf intercellular air spaces is close to zero.

    PubMed

    Laisk, A; Kull, O; Moldau, H

    1989-07-01

    Transpiration and ozone uptake rates were measured simultaneously in sunflower leaves at different stomatal openings and various ozone concentrations. Ozone uptake rates were proportional to the ozone concentration up to 1500 nanoliters per liter. The leaf gas phase diffusion resistance (stomatal plus boundary layer) to water vapor was calculated and converted to the resistance to ozone multiplying it by the theoretical ratio of diffusion coefficients for water vapor and ozone in air (1.67). The ozone concentration in intercellular air spaces calculated from the ozone uptake rate and diffusion resistance to ozone scattered around zero. The ozone concentration in intercellular air spaces was measured directly by supplying ozone to the leaf from one side and measuring the equilibrium concentration above the other side, and it was found to be zero. The total leaf resistance to ozone was proportional to the gas phase resistance to water vapor with a coefficient of 1.68. It is concluded that ozone enters the leaf by diffusion through the stomata, and is rapidly decomposed in cell walls and plasmalemma.

  18. Study of a cave's air exchange pattern based on radon concentration and the time dependence of radon concentration in Pál-völgy Cave (Budapest, Hungary)

    NASA Astrophysics Data System (ADS)

    Nagy, H. E.; Horvath, A.; Jordan, Gy.; Szabo, Cs.; Kiss, A.

    2012-04-01

    A long-term (one year and a half), high resolution, with an integration time of one hour, radon concentration monitoring was carried out in Pál-völgy Cave (Budapest, Hungary). Our major goal was to determine the time dependence of radon concentration in the cave and to understand the exchange pattern of the cave air with the outdoor air based on radon concentrations, and to determine the factors that affect the radon concentration in the cave air. Pál-völgy Cave is situated in the Buda Hills, which is the NE part of the Transdanubian Central Range. The wall rock of the cave is dominantly Eocene Szépvölgy Limestone Formation. Above the limestone Eocene Buda Marl and Oligocene Tard Clay are deposited. A huge multiphase hydrothermal cave system developed in the Szépvölgy Limestone and partially in the Buda Marl resulted in a long-term complex paleokarstic evolution from the Late Eocene to the Quaternary. The radon concentration in the cave air was measured continuously by an AlphaGuard radon monitor, and meteorological parameters outside the cave were also collected simultaneously. The arithmetic mean of the annual radon concentration was 1.9 kBq/m3 and the radon concentration varied between 104-7,776 Bq/m3. In addition, the results indicate a clear seasonal variability of radon concentration in the cave air: in winter the radon concentration fluctuates around a low mean value of 253 Bq/m3, in summer it oscillates around a high mean value of 5,504 Bq/m3, whereas in spring and autumn the radon level varies between the winter and summer values. The summer to winter radon concentration ratio (radon concentration in summer/radon concentration in winter) was high, 21.8. The outside air temperature showed the strongest correlation with the radon concentration in the cave, Pierson's linear correlation coefficient is 0.76. If the outdoor air temperature is lower than the cave air temperature (12 °C), especially in autumn and winter the air flows from outside into the

  19. Measurement of total organic concentration in water

    NASA Technical Reports Server (NTRS)

    Winkler, E.

    1978-01-01

    Instrument for determining total organic concentration in water uses no corrosive reagents or gases. Instead continuous ultraviolet photolysis process converts organic compounds to carbon dioxide (CO2). CO2 electrode is used to measure CO2 content. Only reagent necessary is oxygen, generated in situ by electrolyzing some water. In addition to application in aerospace industry, system has potential uses in pollution monitoring and in laboratory analyses.

  20. Optical measurement of drug concentrations in tissue

    SciTech Connect

    Mourant, J.R.; Bigio, I.J.; Jack, D.A.; Johnson, T.M.; Miller, H.D.

    1997-10-01

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The aim of this project was to develop noninvasive fiber-optic methods for measuring drug concentrations in tissue. Such a system would make possible the study of chemotherapy drug kinetics at specific, targeted locations in the body after the drug is administered. The major result of this project is the development of techniques for measuring changes in absorption of a medium with unknown scattering properties. The developed method was verified by testing on several media with scattering properties in the range typically found for tissue.

  1. Exposure measurement for air-pollution epidemiology

    SciTech Connect

    Ferris, B.G.; Ware, J.H.; Spengler, J.D.

    1988-08-01

    The chapter describes the evolution of air-pollution epidemiology over a period when changes in pollution technologies have both lowered total exposures and dispersed them over vastly greater areas. Since personal exposure and microenvironmental measurements are expensive, studies oriented toward measurements of total exposure will be smaller and more intensive. The shift in emphasis to total human exposure also will affect health risk assessment and raise difficult issues in the regulatory domain. Considering that outdoor exposures (for which EPA has a regulatory mandate) occur in the context of exposures from other sources, the potential effect of regulatory action would probably be small. The regulatory issues are even more difficult for particulate air pollution since cigarette smoking is the strongest determinant of indoor levels but the EPA lacks regulatory responsibility for cigarette smoke.

  2. Investigation of air pollution concentration in Kathmandu valley during winter season.

    PubMed

    Kondo, Akir; Kaga, Akikazu; Imamura, Kiyoshi; Inoue, Yoshio; Sugisawa, Masahiko; Shrestha, Manohar Lal; Sapkota, Balkrishan

    2005-01-01

    The monthly concentrations of NO2, NOx, SO2 and O3 measured by a passive sampler from February 2003 to January 2004 showed that the air pollution during the winter season in Kathmandu valley was higher than the summer season. The O3 level was found the highest during April, May and June due to strong radiation. The hourly concentrations of NO2, NOx, O3 and suspended particulate matter (SPM) were also measured by automatic instruments on December 2003. Temperature at the height of 60 m and 400 m at Raniban Mountain in the northwest of Kathmandu valley was measured on February 2001 in the winter season and the average potential temperature gradient was estimated from observed temperature. Wind speed was also measured at the department of hydrology, airport section, from 18 February to 6 March 2001. It was found that the stable layer and the calm condition in the atmosphere strongly affected the appearance of the maximum concentrations of NO2 and SPM in the morning, and that the unstable layer and the windy condition in the atmosphere was considerably relevant to the decrease of air pollution concentrations at daytime. The emission amounts of NOx, HCs and total suspended particle(TSP) from transport sector in 2003 were estimated from the increasing rate of vehicles on the basis of the emission amounts in 1993 to be 3751 t/a, 30570 t/a and 1317 t/a, respectively. The diurnal concentrations in 2003 calculated by the two-layers box model reproduced the characteristics of air pollution in Kathmandu valley such as the maximum value of O3 and its time, the maximum value of NO in the morning, and the decrease of NO and NO2 at daytime. The comparison with the concentrations in 1993 calculated suggested that the main cause of air pollution was the emission from transport sector.

  3. Bias in air sampling techniques used to measure inhalation exposure.

    PubMed

    Cohen, B S; Harley, N H; Lippmann, M

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and "mini hi-volume" samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. We conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages.

  4. Bias in air sampling techniques used to measure inhalation exposure

    SciTech Connect

    Cohen, B.S.; Harley, N.H.; Lippmann, M.

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and mini hi-volume samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. The authors conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages.

  5. [Estimation of average traffic emission factor based on synchronized incremental traffic flow and air pollutant concentration].

    PubMed

    Li, Run-Kui; Zhao, Tong; Li, Zhi-Peng; Ding, Wen-Jun; Cui, Xiao-Yong; Xu, Qun; Song, Xian-Feng

    2014-04-01

    On-road vehicle emissions have become the main source of urban air pollution and attracted broad attentions. Vehicle emission factor is a basic parameter to reflect the status of vehicle emissions, but the measured emission factor is difficult to obtain, and the simulated emission factor is not localized in China. Based on the synchronized increments of traffic flow and concentration of air pollutants in the morning rush hour period, while meteorological condition and background air pollution concentration retain relatively stable, the relationship between the increase of traffic and the increase of air pollution concentration close to a road is established. Infinite line source Gaussian dispersion model was transformed for the inversion of average vehicle emission factors. A case study was conducted on a main road in Beijing. Traffic flow, meteorological data and carbon monoxide (CO) concentration were collected to estimate average vehicle emission factors of CO. The results were compared with simulated emission factors of COPERT4 model. Results showed that the average emission factors estimated by the proposed approach and COPERT4 in August were 2.0 g x km(-1) and 1.2 g x km(-1), respectively, and in December were 5.5 g x km(-1) and 5.2 g x km(-1), respectively. The emission factors from the proposed approach and COPERT4 showed close values and similar seasonal trends. The proposed method for average emission factor estimation eliminates the disturbance of background concentrations and potentially provides real-time access to vehicle fleet emission factors.

  6. Comparison of mold concentrations quantified by MSQPCR in indoor and outdoor air sampled simultaneously

    SciTech Connect

    Meklin, Teija; Reponen, Tina; McKinstry, Craig A.; Cho, Seung H.; Grinshpun, Sergey A.; Nevalainen, Aino; Vepsalainen, Asko; Haugland, Richard A.; Lemasters, Grace; Vesper, Sephen J.

    2007-08-15

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of 36 mold species in dust and in indoor and in outdoor air samples that were taken simultaneously in 17 homes in Cincinnati with no-known water damage. The total spore concentrations in the indoor (I) and outdoor (O) air samples were statistically significantly different and the concentrations in the three sample types of many of the individual species were significantly different (p < 0.05 based on the Wilcoxon Signed Rank Test). The I/O ratios of the averages or geometric means of the individual species were generally less than 1; but these I/O ratios were quite variable ranging from 0.03 for A. sydowii to 1.2 for Acremonium strictum. There were no significant correlations for the 36 specific mold concentrations between the dust samples and the indoor or outdoor air samples (based on the Spearman’s Rho test). The indoor and outdoor air concentrations of 32 of the species were not correlated. Only Aspergillus penicillioides, C. cladosporioides types 1 and 2 and C. herbarum had sufficient data to estimate a correlation at rho > 0.5 with signicance (p < 0.05) In six of these homes, a previous dust sample had been collected and analyzed 2 years earlier. The ERMI© values for the dust samples taken in the same home two years apart were not significantly different (p=0.22) based on Wilcoxon Signed Rank Test.

  7. 40 CFR 91.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air temperature... Provisions § 91.309 Engine intake air temperature measurement. (a) Engine intake air temperature measurement... the supply system or in the air stream entering the engine. (b) The temperature measurements must...

  8. 40 CFR 91.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine intake air temperature... Provisions § 91.309 Engine intake air temperature measurement. (a) Engine intake air temperature measurement... the supply system or in the air stream entering the engine. (b) The temperature measurements must...

  9. 40 CFR 91.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine intake air temperature... Provisions § 91.309 Engine intake air temperature measurement. (a) Engine intake air temperature measurement... the supply system or in the air stream entering the engine. (b) The temperature measurements must...

  10. 40 CFR 91.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine intake air temperature... Provisions § 91.309 Engine intake air temperature measurement. (a) Engine intake air temperature measurement... the supply system or in the air stream entering the engine. (b) The temperature measurements must...

  11. 40 CFR 91.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine intake air temperature... Provisions § 91.309 Engine intake air temperature measurement. (a) Engine intake air temperature measurement... the supply system or in the air stream entering the engine. (b) The temperature measurements must...

  12. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Air flow measurement specifications. 89.414 Section 89.414 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Emission Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement...

  13. 40 CFR 91.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine intake air humidity measurement... Provisions § 91.310 Engine intake air humidity measurement. This section refers to engines which are supplied... air, the ambient testcell humidity measurement may be used. (a) Humidity conditioned air supply....

  14. 40 CFR 91.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine intake air humidity measurement... Provisions § 91.310 Engine intake air humidity measurement. This section refers to engines which are supplied... air, the ambient testcell humidity measurement may be used. (a) Humidity conditioned air supply....

  15. 40 CFR 91.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine intake air humidity measurement... Provisions § 91.310 Engine intake air humidity measurement. This section refers to engines which are supplied... air, the ambient testcell humidity measurement may be used. (a) Humidity conditioned air supply....

  16. CARS Temperature and Species Measurements For Air Vehicle Propulsion Systems

    NASA Technical Reports Server (NTRS)

    Danehy, Paul M.; Gord, James R.; Grisch, Frederic; Klimenko, Dmitry; Clauss, Walter

    2005-01-01

    The coherent anti-Stokes Raman spectroscopy (CARS) method has recently been used in the United States and Europe to probe several different types of propulsion systems for air vehicles. At NASA Langley Research Center in the United States, CARS has been used to simultaneously measure temperature and the mole fractions of N2, O2 and H2 in a supersonic combustor, representative of a scramjet engine. At Wright- Patterson Air Force Base in the United States, CARS has been used to simultaneously measure temperature and mole fractions of N2, O2 and CO2, in the exhaust stream of a liquid-fueled, gas-turbine combustor. At ONERA in France and the DLR in Germany researchers have used CARS to measure temperature and species concentrations in cryogenic LOX-H2 rocket combustion chambers. The primary aim of these measurements has been to provide detailed flowfield information for computational fluid dynamics (CFD) code validation.

  17. Dependability of Electrochemical Concentration Cell (ECC) Measurements

    NASA Astrophysics Data System (ADS)

    Schmidlin, F. J.; Northam, E. T.; Baldwin, T. M.

    2005-12-01

    It is known that valid measurements from the Electrochemical Concentration Cell (ECC) ozonesonde instrument depend on the control exercise over the pre-flight preparation procedure. NASA Wallops Flight Facility uses preparation procedures designed to detect anomalies that could interfere with obtaining valid ozone profiles. The major factors considered during preparation of an ECC are pump efficiency calibration, volumetric flow rate check, and maintenance of a low background current. Some pre-flight parameters are provided by the manufacturer; nonetheless, these are reconfirmed before they are used. The ECC, prior to release is compared against a well calibrated UV photometer and the offset applied, if desired. The advantage of this pre-release calibration and recent steps to improve the technique are discussed. Preparation of the ECC instrument begins 3-4 weeks prior to the day of observation and the procedure iterated once a week until release occurs. We briefly describe the instrumental tests employed, discuss the effect of different sensing solution concentrations from dual instrument flights, as well as from improved laboratory tests. Comparison of ECC measurements against surface-(Dobson Spectrophotometer) and space-based (AQUA, AURA, and EP-TOMS) measurements are included in our discussion. We postulate reasons for differences, which, in spite of excellent ozonesonde pre-flight quality control and automated data analysis, may be due to uncertainties in both measuring systems.

  18. Catalytic wet air oxidation of high concentration pharmaceutical wastewater.

    PubMed

    Zhan, Wei; Wang, Xiaocong; Li, Daosheng; Ren, Yongzheng; Liu, Dongqi; Kang, Jianxiong

    2013-01-01

    In this study, we investigated the pretreatment of a high concentration pharmaceutical wastewater by catalytic wet air oxidation (CWAO) process. Different experiments were conducted to investigate the effects of the catalyst type, operating temperature, initial system pH, and oxygen partial pressure on the oxidation of the wastewater. Results show that the catalysts prepared by the co-precipitation method have better catalytic activity compared to others. Chemical oxygen demand (COD) conversion increased with the increase in temperature from 160 to 220 °C and decreased with the increase in pH. Moreover, the effect of the oxygen partial pressure on the COD conversion was significant only during the first 20 min of the reaction. Furthermore, the biodegradability of the wastewater improved greatly after CWAO, the ratio of BOD5/COD increased less than 0.1-0.75 when treated at 220 °C (BOD: biochemical oxygen demand). PMID:23676399

  19. Catalytic wet air oxidation of high concentration pharmaceutical wastewater.

    PubMed

    Zhan, Wei; Wang, Xiaocong; Li, Daosheng; Ren, Yongzheng; Liu, Dongqi; Kang, Jianxiong

    2013-01-01

    In this study, we investigated the pretreatment of a high concentration pharmaceutical wastewater by catalytic wet air oxidation (CWAO) process. Different experiments were conducted to investigate the effects of the catalyst type, operating temperature, initial system pH, and oxygen partial pressure on the oxidation of the wastewater. Results show that the catalysts prepared by the co-precipitation method have better catalytic activity compared to others. Chemical oxygen demand (COD) conversion increased with the increase in temperature from 160 to 220 °C and decreased with the increase in pH. Moreover, the effect of the oxygen partial pressure on the COD conversion was significant only during the first 20 min of the reaction. Furthermore, the biodegradability of the wastewater improved greatly after CWAO, the ratio of BOD5/COD increased less than 0.1-0.75 when treated at 220 °C (BOD: biochemical oxygen demand).

  20. Detonation propagation in hydrogen-air mixtures with transverse concentration gradients

    NASA Astrophysics Data System (ADS)

    Boeck, L. R.; Berger, F. M.; Hasslberger, J.; Sattelmayer, T.

    2016-03-01

    The influence of transverse concentration gradients on detonation propagation in H_2-air mixtures is investigated experimentally in a wide parameter range. Detonation fronts are characterized by means of high-speed shadowgraphy, OH* imaging, pressure measurements, and soot foils. Steep concentration gradients at low average H_2 concentrations lead to single-headed detonations. A maximum velocity deficit compared to the Chapman-Jouguet velocity of 9 % is observed. Significant amounts of mixture seem to be consumed by turbulent deflagration behind the leading detonation. Wall pressure measurements show high local pressure peaks due to strong transverse waves caused by the concentration gradients. Higher average H_2 concentrations or weaker gradients allow for multi-headed detonation propagation.

  1. Well-defined critical association concentration and rapid adsorption at the air/water interface of a short amphiphilic polymer, amphipol A8-35: a study by Förster resonance energy transfer and dynamic surface tension measurements.

    PubMed

    Giusti, Fabrice; Popot, Jean-Luc; Tribet, Christophe

    2012-07-17

    Amphipols (APols) are short amphiphilic polymers designed to handle membrane proteins (MPs) in aqueous solutions as an alternative to small surfactants (detergents). APols adsorb onto the transmembrane, hydrophobic surface of MPs, forming small, water-soluble complexes, in which the protein is biochemically stabilized. At variance with MP/detergent complexes, MP/APol ones remain stable even at extreme dilutions. Pure APol solutions self-associate into well-defined micelle-like globules comprising a few APol molecules, a rather unusual behavior for amphiphilic polymers, which typically form ill-defined assemblies. The best characterized APol to date, A8-35, is a random copolymer of acrylic acid, isopropylacrylamide, and octylacrylamide. In the present work, the concentration threshold for self-association of A8-35 in salty buffer (NaCl 100 mM, Tris/HCl 20 mM, pH 8.0) has been studied by Förster resonance energy transfer (FRET) measurements and tensiometry. In a 1:1 mol/mol mixture of APols grafted with either rhodamine or 7-nitro-1,2,3-benzoxadiazole, the FRET signal as a function of A8-35 concentration is essentially zero below a threshold concentration of 0.002 g·L(-1) and increases linearly with concentration above this threshold. This indicates that assembly takes place in a narrow concentration interval around 0.002 g·L(-1). Surface tension measurements decreases regularly with concentration until a threshold of ca. 0.004 g·L(-1), beyond which it reaches a plateau at ca. 30 mN·m(-1). Within experimental uncertainties, the two techniques thus yield a comparable estimate of the critical self-assembly concentration. The kinetics of variation of the surface tension was analyzed by dynamic surface tension measurements in the time window 10 ms-100 s. The rate of surface tension decrease was similar in solutions of A8-35 and of the anionic surfactant sodium dodecylsulfate when both compounds were at a similar molar concentration of n-alkyl moieties. Overall, the

  2. Indoor air quality measurements in 38 Pacific Northwest commercial buildings

    SciTech Connect

    Turk, B.H.; Brown, J.T.; Geisling-Sobotka, K.; Froehlich, D.A.; Grimsrud, D.T.; Harrison, J.; Revzan, K.L.

    1986-06-01

    A Bonneville Power Administration-funded study monitored ventilation rates and a variety of indoor air pollutants in 38 Pacific Northwest commercial buildings. The buildings ranged in age from 6 months to 90 years, in size from 864 to 34,280 m/sup 2/, and occupancy from 25 to 2500 people. Building average formaldehyde (HCHO) concentrations were below the 20 ppB detection limit in 48% of the buildings. Nitrogen dioxide (NO/sub 2/) concentration averages ranged from 5 ppB to 43 ppB and were lower than outdoor concentrations in 8 of 13 buildings. At only one site, an elementary school classroom, did carbon dioxide (CO/sub 2/) exceed 1000 ppM. Radon (Rn) levels were elevated in one building with an average concentration of 7.4 pCiL/sup -1/. Respirable particles (RSP) concentrations in smoking areas in 32 buildings had a geometric mean of 44 ..mu..g m/sup -3/ and ranged up to 308 ..mu..g m/sup -3/ at one site. In non-smoking areas the geometric mean RSP was 15 ..mu..g m/sup -3/. Outside air ventilation rates did not appear to be the single dominant parameter in determining indoor pollutant concentrations. Measured pollutant concentrations in 2 ''complaint'' buildings were below accepted guidelines. The cause of the complaints was not identified.

  3. Fungal spore concentrations in two haematopoietic stem cell transplantation (HSCT) units containing distinct air control systems.

    PubMed

    Brun, C P; Miron, D; Silla, L M R; Pasqualotto, A C

    2013-04-01

    Invasive fungal diseases have emerged as important causes of morbidity and mortality in haematological patients. In this study air samples were collected in two haematopoietic stem cell transplantation (HSCT) units, in which distinct air-control systems were in place. In hospital 1 no high-efficiency particulate air (HEPA) filter was available whereas in hospital 2 HSCT rooms were equipped with HEPA filters, with positive air pressure in relation to the corridor. A total of 117 samples from rooms, toilets and corridors were obtained during December 2009 to January 2011, using a six-stage Andersen sampler. In both hospitals, the concentration of potentially pathogenic fungi in the air was reduced in patients' rooms compared to corridors (P < 0·0001). Despite the presence of a HEPA filter in hospital 2, rooms in both hospitals showed similar concentrations of potentially pathogenic fungi (P = 0·714). These findings may be explained by the implementation of additional protective measures in hospital 1, emphasizing the importance of such measures in protected environments. PMID:22691688

  4. Air concentrations of PBDEs on in-flight airplanes and assessment of flight crew inhalation exposure.

    PubMed

    Allen, Joseph G; Sumner, Ann Louise; Nishioka, Marcia G; Vallarino, Jose; Turner, Douglas J; Saltman, Hannah K; Spengler, John D

    2013-07-01

    To address the knowledge gaps regarding inhalation exposure of flight crew to polybrominated diphenyl ethers (PBDEs) on airplanes, we measured PBDE concentrations in air samples collected in the cabin air at cruising altitudes and used Bayesian Decision Analysis (BDA) to evaluate the likelihood of inhalation exposure to result in the average daily dose (ADD) of a member of the flight crew to exceed EPA Reference Doses (RfDs), accounting for all other aircraft and non-aircraft exposures. A total of 59 air samples were collected from different aircraft and analyzed for four PBDE congeners-BDE 47, 99, 100 and 209 (a subset were also analyzed for BDE 183). For congeners with a published RfD, high estimates of ADD were calculated for all non-aircraft exposure pathways and non-inhalation exposure onboard aircraft; inhalation exposure limits were then derived based on the difference between the RfD and ADDs for all other exposure pathways. The 95th percentile measured concentrations of PBDEs in aircraft air were <1% of the derived inhalation exposure limits. Likelihood probabilities of 95th percentile exposure concentrations >1% of the defined exposure limit were zero for all congeners with published RfDs.

  5. Air conditioning impact on the dynamics of radon and its daughters concentration.

    PubMed

    Kozak, Krzysztof; Grządziel, Dominik; Połednik, Bernard; Mazur, Jadwiga; Dudzińska, Marzenna R; Mroczek, Mariusz

    2014-12-01

    Radon and its decay products are harmful pollutants present in indoor air and are responsible for the majority of the effective dose due to ionising radiation that people are naturally exposed to. The paper presents the results of the series of measurements of radon and its progeny (in unattached and attached fractions) as well as indoor air parameters: temperature, relative humidity, number and mass concentrations of fine aerosol particles. The measurements were carried out in the auditorium (lecture hall), which is an indoor air quality laboratory, in controlled conditions during two periods of time: when air conditioning (AC) was switched off (unoccupied auditorium) and when it was switched on (auditorium in normal use). The significant influence of AC and of students' presence on the dynamics of radon and its progeny was confirmed. A decrease in the mean value of radon and its attached progeny was found when AC was working. The mean value of radon equilibrium factor F was also lower when AC was working (0.49) than when it was off (0.61). The linear correlations were found between attached radon progeny concentration and particle number and mass concentration only when the AC was switched off. This research is being conducted with the aim to study the variability of radon equilibrium factor F which is essential to determine the effective dose due to radon and its progeny inhalation.

  6. Air concentrations of PBDEs on in-flight airplanes and assessment of flight crew inhalation exposure.

    PubMed

    Allen, Joseph G; Sumner, Ann Louise; Nishioka, Marcia G; Vallarino, Jose; Turner, Douglas J; Saltman, Hannah K; Spengler, John D

    2013-07-01

    To address the knowledge gaps regarding inhalation exposure of flight crew to polybrominated diphenyl ethers (PBDEs) on airplanes, we measured PBDE concentrations in air samples collected in the cabin air at cruising altitudes and used Bayesian Decision Analysis (BDA) to evaluate the likelihood of inhalation exposure to result in the average daily dose (ADD) of a member of the flight crew to exceed EPA Reference Doses (RfDs), accounting for all other aircraft and non-aircraft exposures. A total of 59 air samples were collected from different aircraft and analyzed for four PBDE congeners-BDE 47, 99, 100 and 209 (a subset were also analyzed for BDE 183). For congeners with a published RfD, high estimates of ADD were calculated for all non-aircraft exposure pathways and non-inhalation exposure onboard aircraft; inhalation exposure limits were then derived based on the difference between the RfD and ADDs for all other exposure pathways. The 95th percentile measured concentrations of PBDEs in aircraft air were <1% of the derived inhalation exposure limits. Likelihood probabilities of 95th percentile exposure concentrations >1% of the defined exposure limit were zero for all congeners with published RfDs. PMID:22739680

  7. Air conditioning impact on the dynamics of radon and its daughters concentration.

    PubMed

    Kozak, Krzysztof; Grządziel, Dominik; Połednik, Bernard; Mazur, Jadwiga; Dudzińska, Marzenna R; Mroczek, Mariusz

    2014-12-01

    Radon and its decay products are harmful pollutants present in indoor air and are responsible for the majority of the effective dose due to ionising radiation that people are naturally exposed to. The paper presents the results of the series of measurements of radon and its progeny (in unattached and attached fractions) as well as indoor air parameters: temperature, relative humidity, number and mass concentrations of fine aerosol particles. The measurements were carried out in the auditorium (lecture hall), which is an indoor air quality laboratory, in controlled conditions during two periods of time: when air conditioning (AC) was switched off (unoccupied auditorium) and when it was switched on (auditorium in normal use). The significant influence of AC and of students' presence on the dynamics of radon and its progeny was confirmed. A decrease in the mean value of radon and its attached progeny was found when AC was working. The mean value of radon equilibrium factor F was also lower when AC was working (0.49) than when it was off (0.61). The linear correlations were found between attached radon progeny concentration and particle number and mass concentration only when the AC was switched off. This research is being conducted with the aim to study the variability of radon equilibrium factor F which is essential to determine the effective dose due to radon and its progeny inhalation. PMID:24375376

  8. Use of dust fall filters as passive samplers for metal concentrations in air for communities near contaminated mine tailings

    PubMed Central

    Beamer, P.I.; Sugeng, A. J.; Kelly, M.D.; Lothrop, N.; Klimecki, W.; Wilkinson, S.T.; Loh, M.

    2014-01-01

    Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p<0.05), whose primary source in indoor air is resuspended soil from outdoors. In the second rural community, our estimated metal concentrations in air were comparable to active air sampling measurements taken previously. This passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites. PMID:24469149

  9. Method for measuring lead concentrations in blood

    DOEpatents

    Nogar, Nicholas S.

    2001-01-01

    Method for measuring lead concentrations in blood. The present invention includes the use of resonant laser ablation to analyze .ltoreq.1 .mu.L (or equivalent mass) samples of blood for lead content. A typical finger prick, for example, yields about 10 .mu.L. Solid samples may also readily be analyzed by resonant laser ablation. The sample is placed on a lead-free, electrically conducting substrate and irradiated with a single, focused laser beam which simultaneously vaporizes, atomizes, and resonantly ionizes an analyte of interest in a sample. The ions are then sorted, collected and detected using a mass spectrometer.

  10. 40 CFR 92.108 - Intake and cooling air measurements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... recommended practice J244 (incorporated by reference at § 92.5) are allowed. (b) Humidity and temperature measurements. (1) Air that has had its absolute humidity altered is considered humidity-conditioned air. For this type of intake air supply, the humidity measurements must be made within the intake air...

  11. 40 CFR 92.108 - Intake and cooling air measurements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... practice J244 (incorporated by reference at § 92.5) are allowed. (b) Humidity and temperature measurements. (1) Air that has had its absolute humidity altered is considered humidity-conditioned air. For this type of intake air supply, the humidity measurements must be made within the intake air supply...

  12. 40 CFR 92.108 - Intake and cooling air measurements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... recommended practice J244 (incorporated by reference at § 92.5) are allowed. (b) Humidity and temperature measurements. (1) Air that has had its absolute humidity altered is considered humidity-conditioned air. For this type of intake air supply, the humidity measurements must be made within the intake air...

  13. 40 CFR 92.108 - Intake and cooling air measurements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... recommended practice J244 (incorporated by reference at § 92.5) are allowed. (b) Humidity and temperature measurements. (1) Air that has had its absolute humidity altered is considered humidity-conditioned air. For this type of intake air supply, the humidity measurements must be made within the intake air...

  14. Seasonal change of persistent organic pollutant concentrations in air at Niigata area, Japan.

    PubMed

    Murayama, Hitoshi; Takase, Yuuya; Mitobe, Hideko; Mukai, Hiroyuki; Ohzeki, Toshiharu; Shimizu, Ken-ichi; Kitayama, Yoshie

    2003-07-01

    The concentrations of persistent organic pollutants (POPs), such as HCB, alpha-, beta-, gamma- and delta-HCH, trans- and cis-chlordane (t-CHL, c-CHL), DDE, DDD and DDT, in ambient air have been measured at five sampling points in Niigata area, Japan (Niigata, Maki, Tsubame, Jouzo and Yahiko) during the period from September 1999 to November 2001. HCB, alpha-HCH, t-CHL and c-CHL showed higher concentrations than the other chemicals in all locations. All the POPs except t-CHL and c-CHL collected at urban sites of the Niigata Plain was almost the same in their concentration levels. Higher concentrations of t-CHL and c-CHL in residential areas should be attributed to the past usage of the chemical as a termiticide. At Yahiko (remote site), most of the POPs showed lower concentrations than those measured at the other sampling sites, although alpha-HCH and gamma-HCH were comparable with the concentrations found at the other sampling sites. All POPs except alpha-HCH and gamma-HCH tend to decrease 41-80% in their concentrations from 2000 to 2001. The lower POPs concentrations in winter and the higher POPs concentrations in summer at every sampling point can be partly explained by temperature differences. Applying the equation of the logarithm of the POP partial pressure in air versus reciprocal temperature (lnPa=m/T+b) to our data, linear relations were observed. HCB gave a poor linearity and the smallest slope, while beta-HCH, t-CHL and c-CHL gave good linearities and large slopes in the equation. The results suggest that HCB level is influenced by not only the emission from terrestrial sources but the global-scale background pollution. A peculiar observation is that beta-HCH concentration measured in our study showed large temperature dependence, indicating there could be a source of contamination in the surrounding areas. PMID:12738282

  15. Autism spectrum disorder prevalence and associations with air concentrations of lead, mercury, and arsenic.

    PubMed

    Dickerson, Aisha S; Rahbar, Mohammad H; Bakian, Amanda V; Bilder, Deborah A; Harrington, Rebecca A; Pettygrove, Sydney; Kirby, Russell S; Durkin, Maureen S; Han, Inkyu; Moyé, Lemuel A; Pearson, Deborah A; Wingate, Martha Slay; Zahorodny, Walter M

    2016-07-01

    Lead, mercury, and arsenic are neurotoxicants with known effects on neurodevelopment. Autism spectrum disorder (ASD) is a neurodevelopmental disorder apparent by early childhood. Using data on 4486 children with ASD residing in 2489 census tracts in five sites of the Centers for Disease Control and Prevention's Autism and Developmental Disabilities Monitoring (ADDM) Network, we used multi-level negative binomial models to investigate if ambient lead, mercury, and arsenic concentrations, as measured by the US Environmental Protection Agency National-Scale Air Toxics Assessment (EPA-NATA), were associated with ASD prevalence. In unadjusted analyses, ambient metal concentrations were negatively associated with ASD prevalence. After adjusting for confounding factors, tracts with air concentrations of lead in the highest quartile had significantly higher ASD prevalence than tracts with lead concentrations in the lowest quartile (prevalence ratio (PR) = 1.36; 95 '% CI: 1.18, 1.57). In addition, tracts with mercury concentrations above the 75th percentile (>1.7 ng/m(3)) and arsenic concentrations below the 75th percentile (≤0.13 ng/m(3)) had a significantly higher ASD prevalence (adjusted RR = 1.20; 95 % CI: 1.03, 1.40) compared to tracts with arsenic, lead, and mercury concentrations below the 75th percentile. Our results suggest a possible association between ambient lead concentrations and ASD prevalence and demonstrate that exposure to multiple metals may have synergistic effects on ASD prevalence.

  16. Soil air carbon dioxide and nitrous oxide concentrations in profiles under tallgrass prairie and cultivation

    SciTech Connect

    Sotomayor, D.; Rice, C.W.

    1999-05-01

    Assessing the dynamics of gaseous production in soils is of interest because they are important sources and sinks of greenhouse gases. Changes in soil air carbon dioxide (CO{sub 2}) and nitrous oxide (N{sub 2}O) concentrations were studied in a Reading silt loam under prairie and cultivation. Concentrations were measured in situ over a 17-mo period to a depth of 3 m. Multilevel samples permitted collection of gases with subsequent measurement by gas chromatography in the laboratory. Soil air N{sub 2}O concentrations were near atmospheric levels for a majority of the study period in the prairie site but were significantly higher in the cultivated site. Annual mean N{sub 2}O concentrations were 0.403 and 1.09 {micro}L L{sup {minus}1} in the prairie and cultivated sites, respectively. Soil air CO{sub 2} annual mean concentrations were 1.56 {times} 10{sup 4} and 1.10 {times} 10{sup 4} {micro}L L{sup {minus}1} and ranged from 0.096 {times} 10{sup 4} to 6.45 {times} 10{sup 4} {micro}L L{sup {minus}1} and 0.087 {times} 10{sup 4} to 3.59 {times} 10{sup 4} {micro}L L{sup {minus}1} in the prairie and cultivated sites, respectively. Concentrations generally increased with depth, with maximum soil air N{sub 2}O and CO{sub 2} concentrations at 1.0 m in the prairie site and 0.5 m in the cultivated site. Nitrous oxide in the cultivated site and CO{sub 2} at both sites did not change markedly over winter months, but CO{sub 2} and N{sub 2}O concentrations reached maximums during the summer months and decreased as the year progressed. Although soil air concentrations peaked and decreased faster at shallower depths, deeper depths exhibited relative maximum concentrations for longer time periods.

  17. 40 CFR 90.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Intake air flow measurement... Gaseous Exhaust Test Procedures § 90.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure...

  18. 40 CFR 90.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Intake air flow measurement... Gaseous Exhaust Test Procedures § 90.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure...

  19. 40 CFR 90.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Intake air flow measurement... Gaseous Exhaust Test Procedures § 90.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure...

  20. 40 CFR 90.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Intake air flow measurement... Gaseous Exhaust Test Procedures § 90.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure...

  1. The influence of thoron on instruments measuring radon activity concentration.

    PubMed

    Michielsen, N; Bondiguel, S

    2015-11-01

    Thoron, the isotope 220 of radon, is a radionuclide whose concentration may influence the measurement of the activity concentration of (222)Rn in the air. If in the case of continuous and active sampling measuring instruments, using a pump for example, the influence of thoron on radon measurement is obvious and is taken into account in the apparatus, it is often assumed that in the case of a passive sampling, by diffusion through a filter for example, this thoron influence is negligible. This is due to the very short radioactive half-life of thoron, 55.6 s (3.82 d for (222)Rn), and the assumption that the diffusion time of thoron in the detection chamber is long enough beside that of the thoron half-life. The objective of this study is to check whether this assumption is true or not for different kinds of commercial electronic apparatus used to measure radon activity concentration from soil to dwellings. First of all, the devices were calibrated in activity concentration of radon, and then they were exposed to a controlled thoron atmosphere. The experiments concerning the thoron aimed to investigate the sensitivity to thoron in the radon measuring mode of the apparatus. Results of these experiments show that all devices have a very quick answer to thoron atmosphere, even though the sensitivities vary from one instrument to another. Results clearly show that this influence on radon measurement due to the thoron is observed also after the exposition because of the decay of (212)Pb and its progenies. In conclusion, the sensitivity to thoron in the radon measuring mode depends strongly on the type of instruments. The results of the present investigation show that for some apparatus, the influence of thoron cannot be disregarded especially when measuring radon in soil.

  2. IMPACT OF AN OZONE GENERATOR AIR CLEANER ON STYRENE CONCENTRATIONS IN AN INDOOR AIR QUALITY RESEARCH CHAMBER

    EPA Science Inventory

    The paper gives results of an investigation of the impact of an ozone generator air cleaner on vapor-phase styrene concentrations in a full-scale indoor air quality test chamber. The time history of the concentrations of styrene and ozone is well predicted by a simulation model u...

  3. 10 CFR 835.209 - Concentrations of radioactive material in air.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Concentrations of radioactive material in air. 835.209... External Exposure § 835.209 Concentrations of radioactive material in air. (a) The derived air... exposures to airborne radioactive material. (b) The estimation of internal dose shall be based on...

  4. 40 CFR 89.325 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air temperature... Test Equipment Provisions § 89.325 Engine intake air temperature measurement. (a) Engine intake air temperature measurement must be made within 122 cm of the engine. The measurement location must be made...

  5. 40 CFR 89.325 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine intake air temperature... Test Equipment Provisions § 89.325 Engine intake air temperature measurement. (a) Engine intake air temperature measurement must be made within 122 cm of the engine. The measurement location must be made...

  6. 40 CFR 89.325 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine intake air temperature... Test Equipment Provisions § 89.325 Engine intake air temperature measurement. (a) Engine intake air temperature measurement must be made within 122 cm of the engine. The measurement location must be made...

  7. 40 CFR 89.325 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine intake air temperature... Test Equipment Provisions § 89.325 Engine intake air temperature measurement. (a) Engine intake air temperature measurement must be made within 122 cm of the engine. The measurement location must be made...

  8. 40 CFR 89.325 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine intake air temperature... Test Equipment Provisions § 89.325 Engine intake air temperature measurement. (a) Engine intake air temperature measurement must be made within 122 cm of the engine. The measurement location must be made...

  9. 40 CFR 90.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine intake air humidity measurement... Emission Test Equipment Provisions § 90.310 Engine intake air humidity measurement. This section refers to... for the engine intake air, the ambient test cell humidity measurement may be used. (a)...

  10. 40 CFR 90.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine intake air humidity measurement... Emission Test Equipment Provisions § 90.310 Engine intake air humidity measurement. This section refers to... for the engine intake air, the ambient test cell humidity measurement may be used. (a)...

  11. 40 CFR 90.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine intake air humidity measurement... Emission Test Equipment Provisions § 90.310 Engine intake air humidity measurement. This section refers to... for the engine intake air, the ambient test cell humidity measurement may be used. (a)...

  12. Natural ³⁷Ar concentrations in soil air: implications for monitoring underground nuclear explosions.

    PubMed

    Riedmann, Robin A; Purtschert, Roland

    2011-10-15

    For on-site inspections (OSI) under the Comprehensive Nuclear-Test-Ban Treaty (CTBT) measurement of the noble gas ³⁷Ar is considered an important technique. ³⁷Ar is produced underground by neutron activation of Calcium by the reaction ⁴⁰Ca(n,α)³⁷Ar. The naturally occurring equilibrium ³⁷Ar concentration balance in soil air is a function of an exponentially decreasing production rate from cosmic ray neutrons with increasing soil depth, diffusive transport in the soil air, and radioactive decay (T(1/2): 35 days). In this paper for the first time, measurements of natural ³⁷Ar activities in soil air are presented. The highest activities of ~100 mBq m⁻³ air are 2 orders of magnitude larger than in the atmosphere and are found in 1.5-2.5 m depth. At depths > 8 m ³⁷Ar activities are < 20 mBq m⁻³ air. After identifying the main ³⁷Ar production and gas transport factors the expected global activity range distribution of ³⁷Ar in shallow subsoil (0.7 m below the surface) was estimated. In high altitude soils, with large amounts of Calcium and with low gas permeability, ³⁷Ar activities may reach values up to 1 Bq m⁻³.

  13. Processes affecting the CO2 concentrations measured in Greenland ice

    NASA Astrophysics Data System (ADS)

    Anklin, Martin; Barnola, Jean-Marc; Schwander, Jakob; Stauffer, Bernhard; Raynaud, Dominique

    1995-09-01

    Detailed CO2 measurements on ice cores from Greenland and Antarctica show different mean CO2 concentrations for samples at the same gas age. The deviation between Antarctic and Greenland CO2 records raises up to 20 ppmv during the last millennium. Based on the present knowledge of the global carbon cycle we can exclude such a high mean interhemispheric difference of the CO2 concentration between high northern and southern latitudes. Diffusive mixing of the air in the firn smoothes out short term variations of the atmospheric CO2 Concentration. Nevertheless, we observe short term CO2 variations in Greenland ice in the range of 10 20 ppmv, which cannot represent atmospheric CO2 variations. Due to the low temperature at Summit, meltlayers can be excluded for most of the ice and they cannot account for the frequent anomalous short term CO2 variations and the elevated mean CO2 concentration in the Greenland ice. In this work we give some clues, that in situ production of CO2 in Greenland ice could build up excess CO2 after pore close of. Possible chemical reactions are the oxidation of organic carbon and the reaction between acidity and carbonate. We conclude that the carbonate-acidity reaction is the most probable process to explain the excess CO2 in the bubbles. The reaction could take place in very small liquid-like veins in cold ice, where the mobility of impurities is higher than in the ice lattice. At present, there exists no technique to measure the carbonate concentration in the ice directly. However, a comparison of CO2 analyses performed with a dry- and a wet-extraction technique allows to estimate the carbonate content of the ice. This estimate indicates a carbonate concentration in Greenland ice of about 0.4±0.2µmol/l and a much lower concentration in Antarctic ice.

  14. Integrated Assessment of Air Pollution Control Measures for Megacities

    NASA Astrophysics Data System (ADS)

    Friedrich, R.; Theloke, J.; Denier-van-der-Gon, H.; Kugler, U.; Kampffmeyer, T.; Roos, J.; Torras, S.

    2012-04-01

    Air pollution in large cities is still a matter of concern. Especially the concentration of fine particles (PM10 and PM2.5) is largest in large cities leading to severe health impacts. Furthermore the PM10 thresholds of the EU Air Quality Directive are frequently exceeded. Thus the question arises, whether the initiated policies and measures for mitigating air pollution are sufficient to meet the air quality targets and - if not - which efficient further pollution mitigation measures exist. These questions have been addressed in the EU research project MEGAPOLI for the four European megacities respectively agglomerations London, Paris, Rhine-Ruhr area and Po valley. Firstly, a reference scenario of future activities and emissions has been compiled for the megacities for the years 2020, 2030 and 2050 for all relevant air pollutants (CO, NH3, NMVOC, NOx, PM10, PM2.5 and SO2) and greenhouse gases (CO2, CH4 and N2O). The reference scenario takes into account as well population changes as technical progress and economic growth. As pollution flowing in from outside the city is about as important as pollution caused by emissions in the city, the analysis covers the whole of Europe and not only the city area. Emissions are then transformed into concentrations using atmospheric models. The higher concentrations in cities were estimated with a newly developed 'urban increment' model. Results show, that in the megacities the limits of the Air Quality Directive (2008/50/EC) will be exceeded. Thus additional efforts are necessary to reduce emissions further. Thus, a number of further measures (not implemented in current legislation) were selected and assessed. These included mitigation options for road transport, other mobile sources, large combustion plants, small and medium combustion plants and industry. For each measure and in addition for various bundles of measures a cost-benefit analysis has been carried out. Benefits (avoided health risks and climate change risks) have

  15. The Impact of Future Emissions Changes on Air Pollution Concentrations and Related Human Health Effects

    NASA Astrophysics Data System (ADS)

    Mikolajczyk, U.; Suppan, P.; Williams, M.

    2015-12-01

    Quantification of potential health benefits of reductions in air pollution on the local scale is becoming increasingly important. The aim of this study is to conduct health impact assessment (HIA) by utilizing regionally and spatially specific data in order to assess the influence of future emission scenarios on human health. In the first stage of this investigation, a modeling study was carried out using the Weather Research and Forecasting (WRF) model coupled with Chemistry to estimate ambient concentrations of air pollutants for the baseline year 2009, and for the future emission scenarios in southern Germany. Anthropogenic emissions for the baseline year 2009 are derived from the emission inventory provided by the Netherlands Organization of Applied Scientific Research (TNO) (Denier van der Gon et al., 2010). For Germany, the TNO emissions were replaced by gridded emission data with a high spatial resolution of 1/64 x 1/64 degrees. Future air quality simulations are carried out under different emission scenarios, which reflect possible energy and climate measures in year 2030. The model set-up included a nesting approach, where three domains with horizontal resolution of 18 km, 6 km and 2 km were defined. The simulation results for the baseline year 2009 are used to quantify present-day health burdens. Concentration-response functions (CRFs) for PM2.5 and NO2 from the WHO Health risks of air Pollution in Europe (HRAPIE) project were applied to population-weighted mean concentrations to estimate relative risks and hence to determine numbers of attributable deaths and associated life-years lost. In the next step, future health impacts of projected concentrations were calculated taking into account different emissions scenarios. The health benefits that we assume with air pollution reductions can be used to provide options for future policy decisions to protect public health.

  16. Quantile regression of indoor air concentrations of volatile organic compounds (VOC).

    PubMed

    Schlink, Uwe; Thiem, Alexander; Kohajda, Tibor; Richter, Matthias; Strebel, Kathrin

    2010-08-15

    There are many factors determining the concentration of volatile organic compounds (VOCs) in indoor air. On the basis of 601 population-based measurements we develop an explicit exposure model that includes factors, such as renovation, furniture, flat size, smoking, and education level of the occupants. As a novel method for the evaluation of concentrations of indoor air pollutants we use quantile regression, which has the advantages of robustness against non-Gaussian distributions (and outliers) and can adjust for unbalanced frequencies of observations. The applied bi- and multivariate quantile regressions provide (1) the VOC burden that is representative for the population of Leipzig, Germany, and (2) an inter-comparison of the effects of the studied factors and their levels. As a result, we find strong evidence for factors of general impact on most VOC components, such as the season, flooring, the type of the room, and the size of the apartment. Other impact factors are very specific to the VOC components. For example, wooden flooring (parquet) and new furniture increase the concentration of terpenes as well as the modifying factors high education and sampling in the child's room. Smokers ventilate their flats in an extent that in general reduces the VOC concentrations, except for benzene (contained in tobacco smoke), which is still higher in smoking than in non-smoking flats. Very often dampness is associated with an increased VOC burden in indoor air. An investigation of mixtures emphasises a high burden of co-occurring terpenes in very small and very large apartments.

  17. Analysis of radionuclide concentration in air released through the stack of a radiopharmaceutical production facility based on a medical cyclotron

    NASA Astrophysics Data System (ADS)

    Giardina, M.; Tomarchio, E.; Greco, D.

    2015-11-01

    Positron emitting radionuclides are increasingly used in medical diagnostics and the number of radiopharmaceutical production facilities have been estimated to be growing worldwide. During the process of production and/or patient administration of radiopharmaceuticals, an amount of these radionuclides might become airborne and escape into the environment. Therefore, the analysis of radionuclide concentration in the air released to the stack is a very important issue to evaluate the dose to the population living around the plant. To this end, sampling and measurement of radionuclide concentration in air released through the stack of a Nuclear Medicine Center (NMC), provided with a cyclotron for radiopharmaceuticals production, must be routinely carried out with an automatic measurement system. In this work is presented the air monitoring system realized at "San Gaetano" NMC at Bagheria (Italy) besides the analysis of the recorded stack relesead air concentration data. Sampling of air was carried out continuously and gamma-ray spectrometric measurement are made on-line and for a short time by using a shielded Marinelli beaker filled with sampled air and a gamma detector. The use of this system allows to have 1440 values of air concentration per day from 2002, year of the start of operation with the cyclotron. Therefore, the concentration values are very many and an analysis software is needed to determine the dose to the population. A comparison with the results of a simulation code based on a Gaussian Plume air dispersion modelling allow us to confirm the no-radiological significance of the stack effluent releases in terms of dose to population and to evaluate possible improvements in the plant devices to reduce the air concentration at stack.

  18. Determination of radionuclide concentrations in ground level air using the ASS-500 high volume sampler

    SciTech Connect

    Frenzel, E.; Arnold, D.; Wershofen, H.

    1996-06-01

    A method for determination of radionuclide concentrations in air aerosol samples collected by the high volume aerosol sampler ASS-500 was elaborated. The aerosol sampling station ASS-500 is a Stand alone, all-weather proofed instrument. It is designed for representative sampling of airborne radionuclides from ground level air at a height of about 1.5 m above ground level. The ASS-500 station enables continuous air monitoring both normal and emergency Situations. The collection of aerosols on the Petrianov FPP-15-1.5 type filter out of an air volume of about 100,000 m{sup 3} (sampling period 1 wk) or of about 250,000 m{sup 3} (sampling period 3 wk) admits accurate spectrometric low level measurements of natural and artificial radionuclides. The achieved detection limit is 0.5 {mu}Bq m{sup -3} and 0.2 {mu}Bq m{sup -3} for {sup 137}Cs, respectively. A new developed air flow Meter system allows to enhance the collected air volume to about 150,000 m{sup 3} per week and lowers the detection limit to <0.4 {mu}Bq m{sup -3} for {sup 137}Cs for weekly collected aerosol samples. In Poland the CLOR uses 9 Stations ASS-500 at different sites as atmospheric radioactivity control system. On the basis of spectrometric measurements of natural and artificial radionuclides in the collected aerosol samples at the different sites, CLOR establishes a weekly report about the radiological situation at Poland for responsible authorities. The very low achievable detection limit of the Station ASS-500 due 10 the high air flow fate and the long possible sampling period were the key argument for other government radiation protection authorities in Europe to introduce the Station ASS-500 into their low level radionuclide atmospheric monitoring programs (Austria, Belarus, France, Germany, Iceland, Spain, Switzerland, Ukraine).

  19. Benzo(a)pyrene in Europe: Ambient air concentrations, population exposure and health effects.

    PubMed

    Guerreiro, C B B; Horálek, J; de Leeuw, F; Couvidat, F

    2016-07-01

    This study estimated current benzo(a)pyrene (BaP) concentration levels, population exposure and potential health impacts of exposure to ambient air BaP in Europe. These estimates were done by combining the best available information from observations and chemical transport models through the use of spatial interpolation methods. Results show large exceedances of the European target value for BaP in 2012 over large areas, particularly in central-eastern Europe. Results also show large uncertainties in the concentration estimates in regions with a few or no measurement stations. The estimation of the population exposure to BaP concentrations and its health impacts was limited to 60% of the European population, covering only the modelled areas which met the data quality requirement for modelling of BaP concentrations set by the European directive 2004/107/EC. The population exposure estimate shows that 20% of the European population is exposed to BaP background ambient concentrations above the EU target value and only 7% live in areas with concentrations under the estimated acceptable risk level of 0.12 ng m(-3). This exposure leads to an estimated 370 lung cancer incidences per year, for the 60% of the European population included in the estimation. Emissions of BaP have increased in the last decade with the increase in emissions from household combustion of biomass. At the same time, climate mitigation policies are promoting the use of biomass burning for domestic heating. The current study shows that there is a need for more BaP measurements in areas of low measurement density, particularly where high concentrations are expected, e.g. in Romania, Bulgaria, and other Balkan states. Furthermore, this study shows that the health risk posed by PAH exposure calls for better coordination between air quality and climate mitigation policies in Europe.

  20. Measurement of indoor air quality in two new test houses

    SciTech Connect

    Hodgson, A.T.

    1996-01-01

    This study assessed indoor air quality in two similar, new houses being evaluated for energy performance. One house (A) was built conventionally. The other (B) was an energy-efficient structure. Air samples for individual volatile organic compounds (VOCs), total VOCs (TVOC) and formaldehyde were collected following completion of the interiors of the houses and on several occasions during the following year. Ventilation rates were also determined so that source strengths of airborne contaminants could be estimated with a mass- balance model. There were no substantial differences in indoor air quality between the houses. The TVOC concentrations in House A ranged from 1,700 - 4,400 {mu}p m{sup -3}, with the highest value coinciding with the lowest ventilation rate. The TVOC concentrations in House B were 2,400 - 2,800 {mu}g m{sup -3}. These values are elevated compared to a median value of 700 {mu}g m{sup -3} measured for a large residential study. Formaldehyde concentrations ranged up to 74 {mu}g m{sup -3}. The dominant VOC in both houses was hexanal, an odorous chemical irritant. The concentrations of acetone, pentanal, toluene, alpha-pinene and other aldehydes were also relatively high in both houses. The source strengths of many of the analytes did not decline substantially over the course of the study. The OSB was estimated to contribute substantially to concentrations of formaldehyde and acetone in the houses. The results also suggested that OSB was not the dominant source of pentanal, hexanal and alpha-pinene, all of which had elevated emissions in the houses, possibly from a single source.

  1. 40 CFR 89.326 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine intake air humidity measurement. 89.326 Section 89.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Test Equipment Provisions § 89.326 Engine intake air humidity measurement. (a) Humidity conditioned...

  2. 40 CFR 89.326 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air humidity measurement. 89.326 Section 89.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Test Equipment Provisions § 89.326 Engine intake air humidity measurement. (a) Humidity conditioned...

  3. 40 CFR 89.326 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine intake air humidity measurement. 89.326 Section 89.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Test Equipment Provisions § 89.326 Engine intake air humidity measurement. (a) Humidity conditioned...

  4. 40 CFR 89.326 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine intake air humidity measurement. 89.326 Section 89.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Test Equipment Provisions § 89.326 Engine intake air humidity measurement. (a) Humidity conditioned...

  5. 40 CFR 89.326 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine intake air humidity measurement. 89.326 Section 89.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Test Equipment Provisions § 89.326 Engine intake air humidity measurement. (a) Humidity conditioned...

  6. Spatial and temporal distribution of pesticide air concentrations in Canadian agricultural regions

    NASA Astrophysics Data System (ADS)

    Yao, Yuan; Tuduri, Ludovic; Harner, Tom; Blanchard, Pierrette; Waite, Don; Poissant, Laurier; Murphy, Clair; Belzer, Wayne; Aulagnier, Fabien; Li, Yi-Fan; Sverko, Ed

    The Canadian Pesticide Air Sampling Campaign was initiated in 2003 to assess atmospheric levels of pesticides, especially currently used pesticides (CUPs) in agricultural regions across Canada. In the first campaign during the spring to summer of 2003, over 40 pesticides were detected. The spatial and temporal distribution of pesticides in the Canadian atmosphere was shown to reflect the pesticide usage in each region. Several herbicides including triallate, bromoxynil, MCPA, 2,4-D, dicamba, trifluralin and ethalfluralin were detected at highest levels at Bratt's Lake, SK in the prairie region. Strong relationships between air concentrations and dry depositions were observed at this site. Although no application occurred in the Canadian Prairies in 2003, high air concentrations of lindane ( γ-hexachlorocyclohexane) were still observed at Bratt's Lake and Hafford, SK. Two fungicides (chlorothalonil and metalaxyl) and two insecticides (endosulfan and carbofuran) were measured at highest levels at Kensington, PEI. Maximum concentrations of chlorpyrifos and metolachlor were found at St. Anicet, QC. The southern Ontario site, Egbert showed highest concentration of alachlor. Malathion was detected at the highest level at the west coast site, Abbotsford, BC. In case of legacy chlorinated insecticides, high concentrations of DDT, DDE and dieldrin were detected in British Columbia while α-HCH and HCB were found to be fairly uniform across the country. Chlordane was detected in Ontario, Québec and Prince Edward Island. This study demonstrates that the sources for the observed atmospheric occurrence of pesticides include local current pesticide application, volatilization of pesticide residues from soil and atmospheric transport. In many instances, these data represent the first measurements for certain pesticides in a given part of Canada.

  7. Particulate matter concentrations in residences: an intervention study evaluating stand-alone filters and air conditioners

    PubMed Central

    Batterman, S.; Du, L.; Mentz, G.; Mukherjee, B.; Parker, E.; Godwin, C.; Chin, J.-Y.; O'Toole, A.; Robins, T.; Rowe, Z.; Lewis, T.

    2014-01-01

    This study, a randomized controlled trial, evaluated the effectiveness of free-standing air filters and window air conditioners (ACs) in 126 low-income households of children with asthma. Households were randomized into a control group, a group receiving a free-standing HEPA filter placed in the child's sleeping area, and a group receiving the filter and a window-mounted AC. Indoor air quality (IAQ) was monitored for week-long periods over three to four seasons. High concentrations of particulate matter (PM) and carbon dioxide were frequently seen. When IAQ was monitored, filters reduced PM levels in the child's bedroom by an average of 50%. Filter use varied greatly among households and declined over time, for example, during weeks when pollutants were monitored, filter use was initially high, averaging 84 ± 27%, but dropped to 63 ± 33% in subsequent seasons. In months when households were not visited, use averaged only 34 ± 30%. Filter effectiveness did not vary in homes with central or room ACs. The study shows that measurements over multiple seasons are needed to characterize air quality and filter performance. The effectiveness of interventions using free-standing air filters depends on occupant behavior, and strategies to ensure filter use should be an integral part of interventions. PMID:22145709

  8. The impact of European measures to reduce air pollutants on air quality, human health and climate

    NASA Astrophysics Data System (ADS)

    Turnock, S.; Butt, E. W.; Richardson, T.; Mann, G.; Forster, P.; Haywood, J. M.; Crippa, M.; Janssens-Maenhout, G. G. A.; Johnson, C.; Bellouin, N.; Spracklen, D. V.; Carslaw, K. S.; Reddington, C.

    2015-12-01

    European air quality legislation has reduced emissions of air pollutants across Europe since the 1970s, resulting in improved air quality and benefits to human health but also an unintended impact on regional climate. Here we used a coupled chemistry-climate model and a new policy relevant emission scenario to determine the impact of air pollutant emission reductions over Europe. The emission scenario shows that a combination of technological improvements and end-of-pipe abatement measures in the energy, industrial and road transport sectors reduced European emissions of sulphur dioxide, black carbon and organic carbon by 53%, 59% and 32% respectively. We estimate that these emission reductions decreased European annual mean concentrations of fine particulate matter (PM2.5) by 35%, sulphate by 44%, black carbon (BC) by 56% and particulate organic matter (POM) by 23%. The reduction in PM2.5 concentrations is calculated to have prevented 107,000 (40,000-172,000, 5-95% confidence intervals) premature deaths annually from cardiopulmonary disease and lung cancer across the EU member states. The decrease in aerosol concentrations caused a positive all-sky aerosol radiative forcing at the top of atmosphere over Europe of 2.3±0.06 W m-2 and a positive clear-sky forcing of 1.7±0.05 W m-2. Additionally, the amount of solar radiation incident at the surface over Europe increased by 3.3±0.07 W m-2 under all-sky and by 2.7±0.05 W m-2 under clear-sky conditions. Reductions in BC concentrations caused a 1 Wm-2 reduction in atmospheric absorption. We use an energy budget approximation to show that the aerosol induced radiative changes caused both temperature and precipitation to increase globally and over Europe. Our results show that the implementation of European legislation to reduce the emission of air pollutants has improved air quality and human health over Europe, as well as altered the regional radiative balance and climate.

  9. Air toxics concentrations, source identification, and health risks: An air pollution hot spot in southwest Memphis, TN

    NASA Astrophysics Data System (ADS)

    Jia, Chunrong; Foran, Jeffery

    2013-12-01

    Southwest Memphis is a residential region surrounded by fossil fuel burning, steel, refining, and food processing industries, and considerable mobile sources whose emissions may pose adverse health risks to local residents. This study characterizes cancer and non-cancer risks resulting from exposure to ambient air toxics in southwest Memphis. Air toxics samples were collected at a central location every 6 days from June 5, 2008 to January 8, 2010. Volatile organic compounds (VOCs) were collected in evacuated stainless-steel canisters and aldehydes by DNPH cartridges, and samples were analyzed for 73 target compounds. A total of 60 compounds were detected and 39 were found in over 86% of the samples. Mean concentrations of many compounds were higher than those measured in many industrial communities throughout the U.S. The cumulative cancer risk associated with exposure to 13 carcinogens found in southwest Memphis air was 2.3 × 10-4, four times higher than the national average of 5.0 × 10-5. Three risk drivers were identified: benzene, formaldehyde, and acrylonitrile, which contributed 43%, 19%, and 14% to the cumulative risk, respectively. This is the first field study to confirm acrylonitrile as a potential risk driver. Mobile, secondary, industrial, and background sources contributed 57%, 24%, 14%, and 5% of the risk, respectively. The results of this study indicate that southwest Memphis, a region of significant income, racial, and social disparities, is also a region under significant environmental stress compared with surrounding areas and communities.

  10. Groundwater level and nitrate concentration trends on Mountain Home Air Force Base, southwestern Idaho

    USGS Publications Warehouse

    Williams, Marshall L.

    2014-01-01

    Mountain Home Air Force Base in southwestern Idaho draws most of its drinking water from the regional aquifer. The base is located within the State of Idaho's Mountain Home Groundwater Management Area and is adjacent to the State's Cinder Cone Butte Critical Groundwater Area. Both areas were established by the Idaho Department of Water Resources in the early 1980s because of declining water levels in the regional aquifer. The base also is listed by the Idaho Department of Environmental Quality as a nitrate priority area. The U.S. Geological Survey, in cooperation with the U.S. Air Force, began monitoring wells on the base in 1985, and currently monitors 25 wells for water levels and 17 wells for water quality, primarily nutrients. This report provides a summary of water-level and nitrate concentration data collected primarily between 2001 and 2013 and examines trends in those data. A Regional Kendall Test was run to combine results from all wells to determine an overall regional trend in water level. Groundwater levels declined at an average rate of about 1.08 feet per year. Nitrate concentration trends show that 3 wells (18 percent) are increasing in nitrate concentration trend, 3 wells (18 percent) show a decreasing nitrate concentration trend, and 11 wells (64 percent) show no nitrate concentration trend. Six wells (35 percent) currently exceed the U.S. Environmental Protection Agency's maximum contaminant limit of 10 milligrams per liter for nitrate (nitrite plus nitrate, measured as nitrogen).

  11. Air density measurement with a falling A4 sheet

    NASA Astrophysics Data System (ADS)

    Oladyshkin, Ivan V.; Oladyshkina, Anastasia A.

    2016-09-01

    We propose a simple experiment on the air density measurement which does not require any special equipment: just an A4 sheet of paper, a stopwatch and a ruler. The discussed method uses the most basic air resistance model.

  12. Experimental investigation of saturated polarization spectroscopy for quantitative concentration measurements.

    PubMed

    Reichardt, T A; Giancola, W C; Lucht, R P

    2000-04-20

    Polarization-spectroscopy (PS) line shapes and signal intensities are measured in well-characterized hydrogen-air flames operated over a wide range of equivalence ratios. We use both low (perturbative) and high (saturating) pump beam intensities in the counterpropagating pump-probe geometry. The effects of saturation on the line-center signal intensity and the resonance linewidth are investigated. The PS signal intensities are used to measure relative OH number densities in a series of near-adiabatic flames at equivalence ratios (phi) ranging from 0.5 to 1.5. The use of saturating pump intensities minimizes the effect of pump beam absorption, providing more accurate number density measurements. When calibrated to the calculated OH concentration in the phi = 0.6 flame, the saturated PS number density measurements probing the P(1)(2) transition are in excellent agreement with OH absorption measurements, equilibrium calculations of OH number density, and previous saturated degenerate four-wave mixing OH number density measurements. PMID:18345100

  13. Experimental investigation of saturated polarization spectroscopy for quantatative concentration measurements

    SciTech Connect

    Reichardt, Thomas A.; Giancola, William C.; Lucht, Robert P.

    2000-04-20

    Polarization-spectroscopy (PS) line shapes and signal intensities are measured in well-characterized hydrogen-air flames operated over a wide range of equivalence ratios. We use both low (perturbative) and high (saturating) pump beam intensities in the counterpropagating pump-probe geometry. The effects of saturation on the line-center signal intensity and the resonance linewidth are investigated. The PS signal intensities are used to measure relative OH number densities in a series of near-adiabatic flames at equivalence ratios ({phi}) ranging from 0.5 to 1.5. The use of saturating pump intensities minimizes the effect of pump beam absorption, providing more accurate number density measurements. When calibrated to the calculated OH concentration in the {phi}=0.6 flame, the saturated PS number density measurements probing the P{sub 1}(2) transition are in excellent agreement with OH absorption measurements, equilibrium calculations of OH number density, and previous saturated degenerate four-wave mixing OH number density measurements. (c) 2000 Optical Society of America.

  14. Effect of chimneys on indoor air concentrations of PM 10 and benzo[a]pyrene in Xuan Wei, China

    NASA Astrophysics Data System (ADS)

    Tian, Linwei; Lan, Qing; Yang, Dong; He, Xingzhou; Yu, Ignatius T. S.; Hammond, S. Katharine

    This paper reports the effect of chimneys in reducing indoor air pollution in a lung cancer epidemic area of rural China. Household indoor air pollution concentrations were measured during unvented burning (chimneys blocked) and vented burning (chimneys open) of bituminous coal in Xuan Wei, China. Concentrations of particulate matter with an aerodynamic diameter of 10 μm or less (PM 10) and of benzo[a]pyrene (BaP) were measured in 43 homes during normal activities. The use of chimneys led to significant decreases in indoor air concentrations of particulate matter with an aerodynamic diameter of 10 μm or less (PM 10) by 66% and of benzo[a]pyrene (BaP) by 84%. The average BaP content of PM 10 also decreased by 55% with the installation of a chimney. The reduction of indoor pollution levels by the installation of a chimney supports the epidemiology findings on the health benefits of stove improvement. However, even in the presence of a chimney, the indoor air concentrations for both PM 10 and BaP still exceeded the indoor air quality standards of China. Movement up the energy ladder to cleaner liquid or gaseous fuels is probably the only sustainable indoor air pollution control measure.

  15. Comparison of indoor and outdoor concentrations of CO at a public school. Evaluation of an indoor air quality model

    NASA Astrophysics Data System (ADS)

    Chaloulakou, A.; Mavroidis, I.

    A field study was carried out to investigate the internal and external carbon monoxide (CO) concentration levels of a public school building in Athens, Greece. Simultaneous measurements of indoor and outdoor CO concentrations were conducted using a non-dispersive infrared analyzer. Measurements of mean hourly CO concentrations inside and outside the sampling room were conducted on a 24-h basis for 13 consecutive days during May and June 1999 and for 14 consecutive days during December 1999. The aim of the study was to investigate the attenuation pattern of external pollution levels within the building. The diurnal concentration variations reported for different days during the week show that indoor CO concentrations are in general lower than the respective outdoor levels, and that the morning peaks of indoor concentrations show a delay of 1 h or less compared to the morning peaks of outdoor concentrations. The measured indoor to outdoor concentration ratios show a seasonal variation. An indoor air quality model for the prediction of indoor concentration levels developed by Hayes (J. Air Pollut. Control Assoc. 39 (11) (1989) 1453; J. Air Waste Manage. Assoc. 41 (2) (1991) 161) is coded as a computer program and evaluated using the experimental data. The model results are in good agreement with the indoor concentration measurements, although in some cases the model cannot respond adequately to sharp outdoor concentration changes. The ratio between measured and predicted daily maximum indoor concentration ranges between 0.88 and 1.23. The regression curve between predicted by the model and measured hourly indoor concentrations, for a continuous period of 96 h, has a slope of 0.64 and a coefficient of determination ( R2) of 0.69.

  16. Air quality in postunification Erfurt, East Germany: associating changes in pollutant concentrations with changes in emissions.

    PubMed Central

    Ebelt, S; Brauer, M; Cyrys, J; Tuch, T; Kreyling, W G; Wichmann, H E; Heinrich, J

    2001-01-01

    The unification of East and West Germany in 1990 resulted in sharp decreases in emissions of major air pollutants. This change in air quality has provided an opportunity for a natural experiment to evaluate the health impacts of air pollution. We evaluated airborne particle size distribution and gaseous co-pollutant data collected in Erfurt, Germany, throughout the 1990s and assessed the extent to which the observed changes are associated with changes in the two major emission sources: coal burning for power production and residential heating, and motor vehicles. Continuous data for sulfur dioxide, total suspended particulates (TSP), nitric oxide, carbon monoxide, and meteorologic parameters were available for 1990-1999, and size-selective particle number and mass concentration measurements were made during winters of 1991 and 1998. We used hourly profiles of pollutants and linear regression analyses, stratified by year, weekday/weekend, and hour, using NO and SO(2) as markers of traffic- and heating-related combustion sources, respectively, to study the patterns of various particle size fractions. Supplementary data on traffic and heating-related sources were gathered to support hypotheses linking these sources with observed changes in ambient air pollution levels. Substantially decreased (19-91%) concentrations were observed for all pollutants, with the exception of particles in the 0.01-0.03 microm size range (representing the smallest ultrafine particles that were measured). The number concentration for these particles increased by 115% between 1991 and 1998. The ratio of these ultrafine particles to TSP also increased by more than 500%, indicating a dramatic change in the size distribution of airborne particles. Analysis of hourly concentration patterns indicated that in 1991, concentrations of SO(2) and larger particle sizes were related to residential heating with coal. These peaks were no longer evident in 1998 due to decreases in coal consumption and

  17. Variation and balance of positive air ion concentrations in a boreal forest

    NASA Astrophysics Data System (ADS)

    Hõrrak, U.; Aalto, P. P.; Salm, J.; Komsaare, K.; Tammet, H.; Mäkelä, J. M.; Laakso, L.; Kulmala, M.

    2008-02-01

    Air ions are characterized on the basis of measurements carried out in a boreal forest at the Hyytiälä SMEAR station, Finland, during the BIOFOR III campaign in spring 1999. The air ions were discriminated as small ions (charged molecular aggregates of the diameter of less than 2.5 nm), intermediate ions (charged aerosol particles of the diameter of 2.5-8 nm), and large ions (charged aerosol particles of the diameter of 8-20 nm). Statistical characteristics of the ion concentrations and the parameters of ion balance in the atmosphere are presented separately for the nucleation event days and non-event days. In the steady state, the ionization rate is balanced with the loss of small ions, which is expressed as the product of the small ion concentration and the ion sink rate. The widely known sinks of small ions are the recombination with small ions of opposite polarity and attachment to aerosol particles. The dependence of small ion concentration on the concentration of aerosol particles was investigated applying a model of the bipolar diffusion charging of particles by small ions. When the periods of relative humidity above 95% and wind speed less than 0.6 m s-1 were excluded, then the small ion concentration and the theoretically calculated small ion sink rate were closely negatively correlated (correlation coefficient -87%). However, an extra ion loss term of the same magnitude as the ion loss onto aerosol particles is needed for a quantitative explanation of the observations. This term is presumably due to the small ion deposition on coniferous forest. The hygroscopic growth correction of the measured aerosol particle size distributions was also found to be necessary for the proper estimation of the ion sink rate. In the case of nucleation burst events, the concentration of small positive ions followed the general balance equation, no extra ion loss in addition to the deposition on coniferous forest was detected, and the hypothesis of the conversion of ions

  18. Dense gas boundary layer experiments: Visualization, pressure measurements, concentration evaluation

    SciTech Connect

    Reichenbach, H.; Neuwald, P.; Kuhl, A.L.

    1992-11-01

    This technical report describes methods that were applied to investigate turbulent boundary layers generated by inviscid, baroclinic effects. The Cranz-Schardin 24-sparks camera was used to visualize the interactions of a planar shock wave with a Freon R12-layer. The shock propagates more slowly in the Freon layer than in air because of its smaller sound speed. This causes the shock front to be curved and to be reflected between the wall and the layer interface. As a consequence of the reflection process, a series of compression and expansion waves radiate from the layer. Large fluctuations in the streamwise velocity and in pressure develop for about 1 ms. These waves strongly perturb the interface shear layer, which rapidly transitions to a turbulent boundary flow. Pressure measurements showed that the fluctuations in the Freon layer reach a peak pressure 4 times higher than in the turbulent boundary flow. To characterize the preshock Freon boundary layer, concentration measurements were performed with a differential interferometry technique. The refraction index of Freon R12 is so high that Mach-Zehnder interferometry was not successful in these experiments. The evaluation of the concentration profile is described here in detail. Method and results of corresponding LDV measurements under the same conditions are presented in a different report, EMI Report T 9/92. The authors plan to continue the dense gas layer investigations with the gas combination helium/Freon.

  19. Field methods for measuring concentrated flow erosion

    NASA Astrophysics Data System (ADS)

    Castillo, C.; Pérez, R.; James, M. R.; Quinton, J. N.; Taguas, E. V.; Gómez, J. A.

    2012-04-01

    techniques (3D) for measuring erosion from concentrated flow (pole, laser profilemeter, photo-reconstruction and terrestrial LiDAR) The comparison between two- and three-dimensional methods has showed the superiority of the 3D techniques for obtaining accurate cross sectional data. The results from commonly-used 2D methods can be subject to systematic errors in areal cross section that exceed magnitudes of 10 % on average. In particular, the pole simplified method has showed a clear tendency to understimate areas. Laser profilemeter results show that further research on calibrating optical devices for a variety of soil conditions must be carried out to improve its performance. For volume estimations, photo-reconstruction results provided an excellent approximation to terrestrial laser data and demonstrate that this new remote sensing technique has a promising application field in soil erosion studies. 2D approaches involved important errors even over short measurement distances. However, as well as accuracy, the cost and time requirements of a technique must be considered.

  20. Low-Cost Sensor Units for Measuring Urban Air Quality

    NASA Astrophysics Data System (ADS)

    Popoola, O. A.; Mead, M.; Stewart, G.; Hodgson, T.; McLoed, M.; Baldovi, J.; Landshoff, P.; Hayes, M.; Calleja, M.; Jones, R.

    2010-12-01

    Measurements of selected key air quality gases (CO, NO & NO2) have been made with a range of miniature low-cost sensors based on electrochemical gas sensing technology incorporating GPS and GPRS for position and communication respectively. Two types of simple to operate sensors units have been designed to be deployed in relatively large numbers. Mobile handheld sensor units designed for operation by members of the public have been deployed on numerous occasions including in Cambridge, London and Valencia. Static sensor units have also been designed for long-term autonomous deployment on existing street furniture. A study was recently completed in which 45 sensor units were deployed in the Cambridge area for a period of 3 months. Results from these studies indicate that air quality varies widely both spatially and temporally. The widely varying concentrations found suggest that the urban environment cannot be fully understood using limited static site (AURN) networks and that a higher resolution, more dispersed network is required to better define air quality in the urban environment. The results also suggest that higher spatial and temporal resolution measurements could improve knowledge of the levels of individual exposure in the urban environment.

  1. AMBIENT POLLUTANT CONCENTRATIONS MEASURED BY A MOBILE LABORATORY IN SOUTH BRONX, NY (R827351)

    EPA Science Inventory

    The objective of this study is to characterize the ambient air quality of the South Bronx, New York City (NYC), having high concentrations of diesel trucks and waste transfer facilities. We employed a mobile laboratory for continuous measurements of concentrations of fine part...

  2. VOCs Emissions from Multiple Wood Pellet Types and Concentrations in Indoor Air

    PubMed Central

    Soto-Garcia, Lydia; Ashley, William J.; Bregg, Sandar; Walier, Drew; LeBouf, Ryan; Hopke, Philip K.; Rossner, Alan

    2016-01-01

    Wood pellet storage safety is an important aspect for implementing woody biomass as a renewable energy source. When wood pellets are stored indoors in large quantities (tons) in poorly ventilated spaces in buildings, such as in basements, off-gassing of volatile organic compounds (VOCs) can significantly affect indoor air quality. To determine the emission rates and potential impact of VOC emissions, a series of laboratory and field measurements were conducted using softwood, hardwood, and blended wood pellets manufactured in New York. Evacuated canisters were used to collect air samples from the headspace of drums containing pellets and then in basements and pellet storage areas of homes and small businesses. Multiple peaks were identified during GC/MS and GC/FID analysis, and four primary VOCs were characterized and quantified: methanol, pentane, pentanal, and hexanal. Laboratory results show that total VOCs (TVOCs) concentrations for softwood (SW) were statistically (p < 0.02) higher than blended or hardwood (HW) (SW: 412 ± 25; blended: 203 ± 4; HW: 99 ± 8, ppb). The emission rate from HW was the fastest, followed by blended and SW, respectively. Emissions rates were found to range from 10−1 to 10−5 units, depending upon environmental factors. Field measurements resulted in airborne concentrations ranging from 67 ± 8 to 5000 ± 3000 ppb of TVOCs and 12 to 1500 ppb of aldehydes, with higher concentrations found in a basement with a large fabric bag storage unit after fresh pellet delivery and lower concentrations for aged pellets. These results suggest that large fabric bag storage units resulted in a substantial release of VOCs into the building air. Occupants of the buildings tested discussed concerns about odor and sensory irritation when new pellets were delivered. The sensory response was likely due to the aldehydes. PMID:27022205

  3. LARGE-SCALE PREDICTIONS OF MOBILE SOURCE CONTRIBUTIONS TO CONCENTRATIONS OF TOXIC AIR POLLUTANTS

    EPA Science Inventory

    This presentation shows concentrations and deposition of toxic air pollutants predicted by a 3-D air quality model, the Community Multi Scale Air Quality (CMAQ) modeling system. Contributions from both on-road and non-road mobile sources are analyzed.

  4. Seasonal variations in concentrations, distributions, and air-soil exchange fluxes of dioxin-like polychlorinated biphenyls in Shanghai, China.

    PubMed

    Tian, Yajun; Nie, Zhiqiang; He, Jie; Die, Qingqi; Fang, Yanyan; Liu, Feng; Yang, Yufei; Gao, Xingbao; Huang, Qifei

    2016-02-01

    Dioxin-like polychlorinated biphenyl (dl-PCB) concentrations in ambient air and soil in Shanghai, China, were measured to allow seasonal and spatial differences in the dl-PCB concentrations, profiles, distributions, fugacity fractions, and air-soil fluxes to be determined. The toxic equivalent (TEQ) DL-PCB concentrations in the air were higher in summer (mean 9.46 fg m(-3), range 1.32-26.3 fg m(-3)) than in winter (mean 4.57 fg m(-3), range 1.55-10.9 fg m(-3)). The DL-PCB concentrations in air were different in different areas, and the concentrations decreased in the order industrial areas > commercial and residential areas > suburban areas > rural area. The mean DL-PCB concentration in soil was 0.25 pg TEQ g(-1) dry weight (dw) and the range was 0.05-0.90 pg TEQ g(-1) dw. The highest DL-PCB concentration in soil was found in a sample from a commercial/residential area. The DL-PCB fluxes were negative (-216 pg m(-2) h(-1) in summer and -41.1 pg m(-2) h(-1) in winter), and the fugacity fractions were below 0.5, indicating that dl-PCBs in Shanghai are deposited from the air to the soil in all seasons. The net fluxes were higher in summer than in winter, and the deposition fluxes were higher in industrial areas than in other areas in both summer and winter.

  5. Hazard Assessment of Chemical Air Contaminants Measured in Residences

    SciTech Connect

    Logue, J.M.; McKone, T.E.; Sherman, M. H.; Singer, B.C.

    2010-05-10

    Identifying air pollutants that pose a potential hazard indoors can facilitate exposure mitigation. In this study, we compiled summary results from 77 published studies reporting measurements of chemical pollutants in residences in the United States and in countries with similar lifestyles. These data were used to calculate representative mid-range and upper bound concentrations relevant to chronic exposures for 267 pollutants and representative peak concentrations relevant to acute exposures for 5 activity-associated pollutants. Representative concentrations are compared to available chronic and acute health standards for 97 pollutants. Fifteen pollutants appear to exceed chronic health standards in a large fraction of homes. Nine other pollutants are identified as potential chronic health hazards in a substantial minority of homes and an additional nine are identified as potential hazards in a very small percentage of homes. Nine pollutants are identified as priority hazards based on the robustness of measured concentration data and the fraction of residences that appear to be impacted: acetaldehyde; acrolein; benzene; 1,3-butadiene; 1,4-dichlorobenzene; formaldehyde; naphthalene; nitrogen dioxide; and PM{sub 2.5}. Activity-based emissions are shown to pose potential acute health hazards for PM{sub 2.5}, formaldehyde, CO, chloroform, and NO{sub 2}.

  6. COMPARISON OF METHODS FOR MEASURING CONCENTRATIONS OF SEMIVOLATILE PARTICULATE MATTER

    EPA Science Inventory

    The paper gives results of a comparison of methods for measuring concentrations of semivolatile particulate matter (PM) from indoor-environment, small, combustion sources. Particle concentration measurements were compared for methods using filters and a small electrostatic precip...

  7. Air Quality Science and Regulatory Efforts Require Geostationary Satellite Measurements

    NASA Technical Reports Server (NTRS)

    Pickering, Kenneth E.; Allen, D. J.; Stehr, J. W.

    2006-01-01

    Air quality scientists and regulatory agencies would benefit from the high spatial and temporal resolution trace gas and aerosol data that could be provided by instruments on a geostationary platform. More detailed time-resolved data from a geostationary platform could be used in tracking regional transport and in evaluating mesoscale air quality model performance in terms of photochemical evolution throughout the day. The diurnal cycle of photochemical pollutants is currently missing from the data provided by the current generation of atmospheric chemistry satellites which provide only one measurement per day. Often peak surface ozone mixing ratios are reached much earlier in the day during major regional pollution episodes than during local episodes due to downward mixing of ozone that had been transported above the boundary layer overnight. The regional air quality models often do not simulate this downward mixing well enough and underestimate surface ozone in regional episodes. Having high time-resolution geostationary data will make it possible to determine the magnitude of this lower-and mid-tropospheric transport that contributes to peak eight-hour average ozone and 24-hour average PM2.5 concentrations. We will show ozone and PM(sub 2.5) episodes from the CMAQ model and suggest ways in which geostationary satellite data would improve air quality forecasting. Current regulatory modeling is typically being performed at 12 km horizontal resolution. State and regional air quality regulators in regions with complex topography and/or land-sea breezes are anxious to move to 4-km or finer resolution simulations. Geostationary data at these or finer resolutions will be useful in evaluating such models.

  8. Inhalation of concentrated ambient air particles exacerbates myocardial ischemia in conscious dogs.

    PubMed Central

    Wellenius, Gregory A; Coull, Brent A; Godleski, John J; Koutrakis, Petros; Okabe, Kazunori; Savage, Sara T; Lawrence, Joy E; Murthy, G G Krishna; Verrier, Richard L

    2003-01-01

    Short-term increases in ambient air pollution have been associated with an increased incidence of acute cardiac events. We assessed the effect of inhalation exposure to concentrated ambient particles (CAPs) on myocardial ischemia in a canine model of coronary artery occlusion. Six mongrel dogs underwent thoracotomy for implantation of a vascular occluder around the left anterior descending coronary artery and tracheostomy to facilitate particulate exposure. After recovery (5-13 weeks), pairs of subjects were exposed for 6 hr/day on 3 or 4 consecutive days. Within each pair, one subject was randomly assigned to breathe CAPs on the second exposure day and filtered air at other times. The second subject breathed CAPs on the third exposure day and filtered air at other times. Immediately after each exposure, subjects underwent 5-min coronary artery occlusion. We determined ST-segment elevation, a measure of myocardial ischemia heart rate, and arrhythmia incidence during occlusion from continuous electrocardiograms. Exposure to CAPs (median, 285.7; range, 161.3-957.3 microg/m3) significantly (p = 0.007) enhanced occlusion-induced peak ST-segment elevation in precordial leads V4 (9.4 +/- 1.7 vs. 6.2 +/- 0.9 mm, CAPs vs. filtered air, respectively) and V5 (9.2 +/- 1.3 vs. 7.5 +/- 0.9 mm). ST-segment elevation was significantly correlated with the silicon concentration of the particles and other crustal elements possibly associated with urban street dust (p = 0.003 for Si). No associations were found with CAPs mass or number concentrations. Heart rate was not affected by CAPs exposure. These results suggest that exacerbation of myocardial ischemia during coronary artery occlusion may be an important mechanism of environmentally related acute cardiac events. PMID:12676590

  9. Seasonal variation in vertical volatile compounds air concentrations within a remote hemiboreal mixed forest

    NASA Astrophysics Data System (ADS)

    Noe, S. M.; Hüve, K.; Niinemets, Ü.; Copolovici, L.

    2012-05-01

    The vertical distribution of ambient biogenic volatile organic compounds (BVOC) concentrations within a hemiboreal forest canopy was investigated over a period of one year. Variability in temporal and spatial isoprene concentrations, ranging from 0.1 to 7.5 μg m-3, can be mainly explained by biogenic emissions from deciduous trees. Monoterpene concentrations exceeded isoprene largely and ranged from 0.01 to 140 μg m-3 and during winter time anthropogenic contributions are likely. Variation in monoterpene concentrations were found to be largest right above the ground and the vertical profiles suggest a weak mixing leading to terpene accumulation in the lower canopy. Exceptionally high values were recorded during a heat wave in July 2010 with very high midday temperatures above 30 °C for several weeks. During summer months, monoterpene exceeded isoprene concentrations 6-fold and during winter 12-fold. During summer months, dominance of α-pinene in the lower and of limonene in the upper part of the canopy was observed, both accounting for up to 70% of the total monoterpene concentration. During wintertime, Δ3-carene was the dominant species, accounting for 60% of total monoterpene concentration in January. Possible biogenic monoterpene sources beside the foliage are the leaf litter, the soil and also resins exuding from stems. In comparison, the hemiboreal mixed forest canopy showed similar isoprene but higher monoterpene concentrations than the boreal forest and lower isoprene but substantially higher monoterpene concentrations than the temperate mixed forest canopies. These results have major implications for simulating air chemistry and secondary organic aerosol formation within and above hemiboreal forest canopies. Possible effects of in-cartridge oxidation reactions are discussed as our measurement technique did not include oxidant scavenging. A comparison between measurements with and without scavenging oxidants is presented.

  10. 40 CFR 91.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Intake air flow measurement specifications. 91.416 Section 91.416 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.416 Intake air flow...

  11. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Air flow measurement specifications. 89.414 Section 89.414 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exhaust Emission Test Procedures § 89.414 Air...

  12. 40 CFR 90.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine intake air temperature... Emission Test Equipment Provisions § 90.309 Engine intake air temperature measurement. (a) The measurement...) The temperature measurements must be accurate to within ±2 °C....

  13. 40 CFR 90.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine intake air temperature... Emission Test Equipment Provisions § 90.309 Engine intake air temperature measurement. (a) The measurement...) The temperature measurements must be accurate to within ±2 °C....

  14. 40 CFR 90.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine intake air temperature... Emission Test Equipment Provisions § 90.309 Engine intake air temperature measurement. (a) The measurement...) The temperature measurements must be accurate to within ±2 °C....

  15. 40 CFR 90.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air temperature... Emission Test Equipment Provisions § 90.309 Engine intake air temperature measurement. (a) The measurement...) The temperature measurements must be accurate to within ±2 °C....

  16. 40 CFR 90.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine intake air temperature... Emission Test Equipment Provisions § 90.309 Engine intake air temperature measurement. (a) The measurement...) The temperature measurements must be accurate to within ±2 °C....

  17. High Concentrations of Organic Contaminants in Air from Ship Breaking Activities in Chittagong, Bangladesh.

    PubMed

    Nøst, Therese H; Halse, Anne K; Randall, Scott; Borgen, Anders R; Schlabach, Martin; Paul, Alak; Rahman, Atiqur; Breivik, Knut

    2015-10-01

    The beaches on the coast of Chittagong in Bangladesh are one of the most intense ship breaking areas in the world. The aim of the study was to measure the concentrations of organic contaminants in the air in the city of Chittagong, including the surrounding ship breaking areas using passive air samplers (N = 25). The compounds detected in the highest amounts were the polycyclic aromatic hydrocarbons (PAHs) and short-chain chlorinated paraffins (SCCPs), whereas dichlorodiphenyltrichloroethanes (DDTs), hexachlorobenzene (HCB), and polychlorinated biphenyls (PCBs) were several orders of magnitude lower in comparison. PCBs, PAHs, and HCB were highest at sites near the ship breaking activities, whereas DDTs and SCCPs were higher in the urban areas. Ship breaking activities likely act as atmospheric emission sources of PCBs, PAHs, and HCB, thus adding to the international emphasis on responsible recycling of ships. Concentrations of PAHs, PCBs, DDTs, HCB, and SCCPs in ambient air in Chittagong are high in comparison to those found in similar studies performed in other parts of Asia. Estimated toxic equivalent quotients indicate elevated human health risks caused by inhalation of PAHs at most sites. PMID:26351879

  18. High Concentrations of Organic Contaminants in Air from Ship Breaking Activities in Chittagong, Bangladesh.

    PubMed

    Nøst, Therese H; Halse, Anne K; Randall, Scott; Borgen, Anders R; Schlabach, Martin; Paul, Alak; Rahman, Atiqur; Breivik, Knut

    2015-10-01

    The beaches on the coast of Chittagong in Bangladesh are one of the most intense ship breaking areas in the world. The aim of the study was to measure the concentrations of organic contaminants in the air in the city of Chittagong, including the surrounding ship breaking areas using passive air samplers (N = 25). The compounds detected in the highest amounts were the polycyclic aromatic hydrocarbons (PAHs) and short-chain chlorinated paraffins (SCCPs), whereas dichlorodiphenyltrichloroethanes (DDTs), hexachlorobenzene (HCB), and polychlorinated biphenyls (PCBs) were several orders of magnitude lower in comparison. PCBs, PAHs, and HCB were highest at sites near the ship breaking activities, whereas DDTs and SCCPs were higher in the urban areas. Ship breaking activities likely act as atmospheric emission sources of PCBs, PAHs, and HCB, thus adding to the international emphasis on responsible recycling of ships. Concentrations of PAHs, PCBs, DDTs, HCB, and SCCPs in ambient air in Chittagong are high in comparison to those found in similar studies performed in other parts of Asia. Estimated toxic equivalent quotients indicate elevated human health risks caused by inhalation of PAHs at most sites.

  19. Combining regression analysis and air quality modelling to predict benzene concentration levels

    NASA Astrophysics Data System (ADS)

    Vlachokostas, Ch.; Achillas, Ch.; Chourdakis, E.; Moussiopoulos, N.

    2011-05-01

    State of the art epidemiological research has found consistent associations between traffic-related air pollution and various outcomes, such as respiratory symptoms and premature mortality. However, many urban areas are characterised by the absence of the necessary monitoring infrastructure, especially for benzene (C 6H 6), which is a known human carcinogen. The use of environmental statistics combined with air quality modelling can be of vital importance in order to assess air quality levels of traffic-related pollutants in an urban area in the case where there are no available measurements. This paper aims at developing and presenting a reliable approach, in order to forecast C 6H 6 levels in urban environments, demonstrated for Thessaloniki, Greece. Multiple stepwise regression analysis is used and a strong statistical relationship is detected between C 6H 6 and CO. The adopted regression model is validated in order to depict its applicability and representativeness. The presented results demonstrate that the adopted approach is capable of capturing C 6H 6 concentration trends and should be considered as complementary to air quality monitoring.

  20. Air exchange effectiveness in office buildings: Measurement techniques and results

    SciTech Connect

    Fisk, W.J.; Faulkner, D.

    1992-07-01

    We define two air exchange effectiveness parameters which indicate the extent of short circuiting, mixing, or displacement air flow in an entire building, the air diffusion effectiveness which indicates the air flow pattern locally, and the normalized local age of air. After describing two tracer gas procedures for measuring these parameters, we discuss assumptions inherent in the data analysis that are often violated in large office buildings. To obtain valuable data, careful selection of buildings for measurements and assessments to determine if operating conditions are reasonably consistent with the assumptions are necessary. Multiple factors, in addition to the air flow pattern in the occupied space, can affect measurement results, consequently, the interpretation of measurements is not straightforward. We summarize the results of measurements in several office buildings and in a research laboratory. Almost all measurements indicate that the extent of both short circuiting and displacement flow is small. A moderate amount of short circuiting is evident from a few measurements in rooms with heated supply air. Ages of air and their reciprocals (local ventilation rates) often vary substantially between rooms, probably because of room-to-room variation in the rate of air supply. For future research, we suggest assessments of measurement accuracy, development of measurement approaches that may be practically applied for a broader range of buildings, and a greater focus on pollutant removal efficiencies.

  1. Equipment for Measuring Air Flow, Air Temperature, Relative Humidity, and Carbon Dioxide in Schools. Technical Bulletin.

    ERIC Educational Resources Information Center

    Jacobs, Bruce W.

    Information on equipment and techniques that school facility personnel may use to evaluate IAQ conditions are discussed. Focus is placed on the IAQ parameters of air flow, air temperature, relative humidity, as well as carbon dioxide and the equipment used to measure these factors. Reasons for measurement and for when the measurement of these…

  2. Measurement of Radon in Indoor Air.

    ERIC Educational Resources Information Center

    Downey, Daniel M.; Simolunas, Glenn

    1988-01-01

    Describes a laboratory experiment to teach the principles of air sampling, gamma ray spectroscopy, nuclear decay, and radioactive equilibrium. Analyzes radon by carbon adsorption and gamma ray counting. Provides methodology and rate of decay equations. (MVL)

  3. Effect of geocoding errors on traffic-related air pollutant exposure and concentration estimates.

    PubMed

    Ganguly, Rajiv; Batterman, Stuart; Isakov, Vlad; Snyder, Michelle; Breen, Michael; Brakefield-Caldwell, Wilma

    2015-01-01

    Exposure to traffic-related air pollutants is highest very near roads, and thus exposure estimates are sensitive to positional errors. This study evaluates positional and PM2.5 concentration errors that result from the use of automated geocoding methods and from linearized approximations of roads in link-based emission inventories. Two automated geocoders (Bing Map and ArcGIS) along with handheld GPS instruments were used to geocode 160 home locations of children enrolled in an air pollution study investigating effects of traffic-related pollutants in Detroit, Michigan. The average and maximum positional errors using the automated geocoders were 35 and 196 m, respectively. Comparing road edge and road centerline, differences in house-to-highway distances averaged 23 m and reached 82 m. These differences were attributable to road curvature, road width and the presence of ramps, factors that should be considered in proximity measures used either directly as an exposure metric or as inputs to dispersion or other models. Effects of positional errors for the 160 homes on PM2.5 concentrations resulting from traffic-related emissions were predicted using a detailed road network and the RLINE dispersion model. Concentration errors averaged only 9%, but maximum errors reached 54% for annual averages and 87% for maximum 24-h averages. Whereas most geocoding errors appear modest in magnitude, 5% to 20% of residences are expected to have positional errors exceeding 100 m. Such errors can substantially alter exposure estimates near roads because of the dramatic spatial gradients of traffic-related pollutant concentrations. To ensure the accuracy of exposure estimates for traffic-related air pollutants, especially near roads, confirmation of geocoordinates is recommended.

  4. Effect of geocoding errors on traffic-related air pollutant exposure and concentration estimates

    PubMed Central

    Ganguly, Rajiv; Batterman, Stuart; Isakov, Vlad; Snyder, Michelle; Breen, Michael; Brakefield-Caldwell, Wilma

    2015-01-01

    Exposure to traffic-related air pollutants is highest very near roads, and thus exposure estimates are sensitive to positional errors. This study evaluates positional and PM2.5 concentration errors that result from the use of automated geocoding methods and from linearized approximations of roads in link-based emission inventories. Two automated geocoders (Bing Map and ArcGIS) along with handheld GPS instruments were used to geocode 160 home locations of children enrolled in an air pollution study investigating effects of traffic-related pollutants in Detroit, Michigan. The average and maximum positional errors using the automated geocoders were 35 and 196 m, respectively. Comparing road edge and road centerline, differences in house-to-highway distances averaged 23 m and reached 82 m. These differences were attributable to road curvature, road width and the presence of ramps, factors that should be considered in proximity measures used either directly as an exposure metric or as inputs to dispersion or other models. Effects of positional errors for the 160 homes on PM2.5 concentrations resulting from traffic-related emissions were predicted using a detailed road network and the RLINE dispersion model. Concentration errors averaged only 9%, but maximum errors reached 54% for annual averages and 87% for maximum 24-h averages. Whereas most geocoding errors appear modest in magnitude, 5% to 20% of residences are expected to have positional errors exceeding 100 m. Such errors can substantially alter exposure estimates near roads because of the dramatic spatial gradients of traffic-related pollutant concentrations. To ensure the accuracy of exposure estimates for traffic-related air pollutants, especially near roads, confirmation of geocoordinates is recommended. PMID:25670023

  5. The concentrations of culturable microorganisms in relation to particulate matter in urban air

    NASA Astrophysics Data System (ADS)

    Haas, D.; Galler, H.; Luxner, J.; Zarfel, G.; Buzina, W.; Friedl, H.; Marth, E.; Habib, J.; Reinthaler, F. F.

    2013-02-01

    The ambient air consists not only of gases but also of bioaerosols and particulate matter. The concentrations of particulate matter in relation to the culturable microorganisms in the urban ambient air and their dependence on air temperature and relative humidity were investigated. The seasonal distribution of particles sizes, the concentrations of aerobic mesophilic bacteria and xerophilic fungi in the air were evaluated. Moreover, the identification of the fungal genera Cladosporium, Aspergillus and Penicillium were conducted. Within one year at 177 days particle and microorganism concentrations in the ambient air were recorded in the city centre of Graz/Austria. The results show that the concentrations of fine particles and coarse particles were the highest in winter and decreased continuously to a minimum in the summer months depending on temperature and air humidity. The concentrations of xerophilic fungi showed no correlation to the different particle concentrations. The spore concentrations of Cladosporium spp. showed the same results of xerophilic fungi whereas the genera Penicillium and Aspergillus increased with the increase of fine particles. The concentrations of mesophilic bacteria were positively correlated with all particle counts. The maximum mesophilic bacteria concentrations were found in the winter months. Further studies are required to evaluate the concentrations of specific microorganisms in the natural environment in relation to the particulate matter.

  6. Determination of the concentration and isotopic composition of uranium in environmental air filters

    SciTech Connect

    Russ, G.P. III; Bazan, J.M.

    1994-08-26

    For many years, Lawrence Livermore National Laboratory has collected monthly air-particulate filter samples from a variety of environmental monitoring stations on and off site. Historically the concentration and isotopic composition of uranium collected on these filters was determined by isotope dilution using a {sup 233}U spike and thermal ionization mass spectrometry (TIMS). For samples containing as little as 10 nanograms of uranium, ICP-MS is now used to make these measurements to the required level of precision, about 5% in the measured 235/238 and 233/238. Unless particular care is taken to control bias in the mass filter, variable mass bias limits accuracy to a few percent. Measurements of the minor isotopes 236 (if present) and 234 are also possible and provide useful information for identifying the source of the uranium. The advantage of ICP-MS is in rapid analysis, {approximately}12 minutes of instrument time per sample.

  7. AN INDOOR PESTICIDE AIR AND SURFACE CONCENTRATION MODEL

    EPA Science Inventory

    A thorough assessment of human exposure to environmental chemicals requires consideration of all processes in the sequence from source to dose. For assessment of exposure to pesticides following their use indoors, data and models are needed to estimate pesticide concentrations...

  8. A Conductivity Device for Measuring Sulfur Dioxide in the Air

    ERIC Educational Resources Information Center

    Craig, James C.

    1972-01-01

    Described is a general electroconductivity device enabling students to determine sulfur dioxide concentration in a particular location, hopefully leading to a deeper understanding of the problem of air pollution. (DF)

  9. Concentration, size, and density of total suspended particulates at the air exhaust of concentrated animal feeding operations.

    PubMed

    Yang, Xufei; Lee, Jongmin; Zhang, Yuanhui; Wang, Xinlei; Yang, Liangcheng

    2015-08-01

    Total suspended particulate (TSP) samples were seasonally collected at the air exhaust of 15 commercial concentrated animal feeding operations (CAFOs; including swine finishing, swine farrowing, swine gestation, laying hen, and tom turkey) in the U.S. Midwest. The measured TSP concentrations ranged from 0.38 ± 0.04 mg m⁻³ (swine gestation in summer) to 10.9 ± 3.9 mg m⁻³ (tom turkey in winter) and were significantly affected by animal species, housing facility type, feeder type (dry or wet), and season. The average particle size of collected TSP samples in terms of mass median equivalent spherical diameter ranged from 14.8 ± 0.5 µm (swine finishing in winter) to 30.5 ± 2.0 µm (tom turkey in summer) and showed a significant seasonal effect. This finding affirmed that particulate matter (PM) released from CAFOs contains a significant portion of large particles. The measured particle size distribution (PSD) and the density of deposited particles (on average 1.65 ± 0.13 g cm⁻³) were used to estimate the mass fractions of PM10 and PM2.5 (PM ≤ 10 and ≤ 2.5 μm, respectively) in the collected TSP. The results showed that the PM10 fractions ranged from 12.7 ± 5.1% (tom turkey) to 21.1 ± 3.2% (swine finishing), whereas the PM2.5 fractions ranged from 3.4 ± 1.9% (tom turkey) to 5.7 ± 3.2% (swine finishing) and were smaller than 9.0% at all visited CAFOs. This study applied a filter-based method for PSD measurement and deposited particles as a surrogate to estimate the TSP's particle density. The limitations, along with the assumptions adopted during the calculation of PM mass fractions, must be recognized when comparing the findings to other studies.

  10. Effect of air pollution and environmental tobacco smoke on serum hyaluronate concentrations in school children

    PubMed Central

    Fuji, Y; Shima, M; Ando, M; Adachi, M; Tsunetoshi, Y

    2002-01-01

    Objectives: To evaluate serum hyaluronate concentrations relative to air pollution, environmental tobacco smoke (ETS), and respiratory health in Japanese school children. Methods: Respiratory symptoms and serum IgE concentrations were examined in 1037 school children living in four communities in Japan with differing levels of air pollution. Serum hyaluronate concentrations were assayed in 230 children, consisting of all the children who had symptoms of either asthma or wheeze (65 and 50 subjects, respectively) and normal controls adjusted for sex, school grade, and school without these symptoms (115 subjects). Results: Although serum hyaluronate concentrations did not differ for either asthma or wheeze, the concentrations were significantly higher in children living in communities with higher levels of air pollution. Children with asthma or wheeze and those with serum IgE concentrations of 250 IU/ml or above showed differences in hyaluronate concentrations that related to the degree of air pollution in the communities. In children with higher serum IgE concentrations, the hyaluronate concentrations among subjects exposed to ETS were significantly higher than among those without exposure to ETS. Conclusions: The present results suggest that serum hyaluronate concentration is related to the degree of air pollution and exposure to ETS. Children with asthma or wheeze and children with higher IgE concentrations are considered to be more susceptible to environmental factors. PMID:11850556

  11. Effect of air preheat temperature and oxygen concentration on flame structure and emission

    SciTech Connect

    Bolz, S.; Gupta, A.K.

    1998-07-01

    The structure of turbulent diffusion flames with highly preheated combustion air (air preheat temperature in excess of 1,150 C) has been obtained using a specially designed regenerative combustion furnace. Propane gas was used as the fuel. Data have been obtained on the global flame features, spectral emission characteristics, spatial distribution of OH, CH and C{sub 2} species, and pollutants emission from the flames. The results have been obtained for various degrees of air preheat temperatures and O{sub 2} concentration in the air. The color of the flame was found to change from yellow to blue to bluish-green to green over the range of conditions examined. In some cases a hybrid color flame was also observed. The recorded images of the flame photographs were analyzed using color-analyzing software. The results show that thermal and chemical flame behavior strongly depends on the air preheat temperature and oxygen content in the air. The flame color was found to be bluish-green or green at very high air preheat temperatures and low-oxygen concentration. However, at high oxygen concentration the flame color was yellow. The flame volume was found to increase with increase in air-preheat temperature and decrease in oxygen concentration. The flame length showed a similar behavior. The concentrations of OH, CH and C{sub 2} increased with an increase in air preheat temperatures. These species exhibited a two-stage combustion behavior at low oxygen concentration and single stage combustion behavior at high oxygen concentration in the air. Stable flames were obtained for remarkably low equivalence ratios, which would not be possible with normal combustion air. Pollutants emission, including CO{sub 2} and NO{sub x} , was much lower with highly preheated combustion air at low O{sub 2} concentration than the normal air. The results also suggest uniform flow and flame thermal characteristics with conditioned highly preheated air. Highly preheated air combustion provides much

  12. Perfluorocarbon tracer method for air-infiltration measurements

    DOEpatents

    Dietz, R.N.

    1982-09-23

    A method of measuring air infiltration rates suitable for use in rooms of homes and buildings comprises the steps of emitting perfluorocarbons in the room to be measured, sampling the air containing the emitted perfluorocarbons over a period of time, and analyzing the samples at a laboratory or other facility.

  13. GAS CHROMATOGRAPHIC TECHNIQUES FOR THE MEASUREMENT OF ISOPRENE IN AIR

    EPA Science Inventory

    The chapter discusses gas chromatographic techniques for measuring isoprene in air. Such measurement basically consists of three parts: (1) collection of sufficient sample volume for representative and accurate quantitation, (2) separation (if necessary) of isoprene from interfer...

  14. Measuring Air Resistance in a Computerized Laboratory.

    ERIC Educational Resources Information Center

    Takahashi, Ken; Thompson, D.

    1999-01-01

    Presents an activity that involves dropping spherical party balloons onto a sonic motion sensor to show that the force associated with the air resistance is proportional to both the square of the velocity and the cross-sectional area of the balloon. (Author/WRM)

  15. Next-generation air measurement technologies

    EPA Science Inventory

    This is a presentation at a workshop in Chicago on emerging air monitoring technologies, hosted by a local nonprofit. The audience is composed of a mixture of technical backgrounds. This presentation will be part of an opening panel and the goal is to give an overview of the st...

  16. Analysis of radon and thoron progeny measurements based on air filtration.

    PubMed

    Stajic, J M; Nikezic, D

    2015-02-01

    Measuring of radon and thoron progeny concentrations in air, based on air filtration, was analysed in order to assess the reliability of the method. Changes of radon and thoron progeny activities on the filter during and after air sampling were investigated. Simulation experiments were performed involving realistic measuring parameters. The sensitivity of results (radon and thoron concentrations in air) to the variations of alpha counting in three and five intervals was studied. The concentration of (218)Po showed up to be the most sensitive to these changes, as was expected because of its short half-life. The well-known method for measuring of progeny concentrations based on air filtration is rather unreliable and obtaining unrealistic or incorrect results appears to be quite possible. A simple method for quick estimation of radon potential alpha energy concentration (PAEC), based on measurements of alpha activity in a saturation regime, was proposed. Thoron PAEC can be determined from the saturation activity on the filter, through beta or alpha measurements.

  17. Determinants of perceived air pollution annoyance and association between annoyance scores and air pollution (PM 2.5, NO 2) concentrations in the European EXPOLIS study

    NASA Astrophysics Data System (ADS)

    Rotko, Tuulia; Oglesby, Lucy; Künzli, Nino; Carrer, Paolo; Nieuwenhuijsen, Mark J.; Jantunen, Matti

    Apart from its traditionally considered objective impacts on health, air pollution can also have perceived effects, such as annoyance. The psychological effects of air pollution may often be more important to well-being than the biophysical effects. Health effects of perceived annoyance from air pollution are so far unknown. More knowledge of air pollution annoyance levels, determinants and also associations with different air pollution components is needed. In the European air pollution exposure study, EXPOLIS, the air pollution annoyance as perceived at home, workplace and in traffic were surveyed among other study objectives. Overall 1736 randomly drawn 25-55-yr-old subjects participated in six cities (Athens, Basel, Milan, Oxford, Prague and Helsinki). Levels and predictors of individual perceived annoyances from air pollution were assessed. Instead of the usual air pollution concentrations at fixed monitoring sites, this paper compares the measured microenvironment concentrations and personal exposures of PM 2.5 and NO 2 to the perceived annoyance levels. A considerable proportion of the adults surveyed was annoyed by air pollution. Female gender, self-reported respiratory symptoms, downtown living and self-reported sensitivity to air pollution were directly associated with high air pollution annoyance score while in traffic, but smoking status, age or education level were not significantly associated. Population level annoyance averages correlated with the city average exposure levels of PM 2.5 and NO 2. A high correlation was observed between the personal 48-h PM 2.5 exposure and perceived annoyance at home as well as between the mean annoyance at work and both the average work indoor PM 2.5 and the personal work time PM 2.5 exposure. With the other significant determinants (gender, city code, home location) and home outdoor levels the model explained 14% (PM 2.5) and 19% (NO 2) of the variation in perceived air pollution annoyance in traffic. Compared to

  18. Isolation of Polypeptide Sample and Measurement of Its Concentration.

    ERIC Educational Resources Information Center

    Beanan, Maureen J.

    2000-01-01

    Introduces a laboratory experiment that isolates a bacterial polypeptide sample and measures the concentration of polypeptides in the sample. Uses Escherichia coli strain MM294 and performs a bio-rad assay to determine the concentration of polypeptides. (YDS)

  19. Gas and liquid measurements in air-water bubbly flows

    SciTech Connect

    Zhou, X.; Doup, B.; Sun, X.

    2012-07-01

    Local measurements of gas- and liquid-phase flow parameters are conducted in an air-water two-phase flow loop. The test section is a vertical pipe with an inner diameter of 50 mm and a height of 3.2 m. The measurements are performed at z/D = 10. The gas-phase measurements are performed using a four-sensor conductivity probe. The data taken from this probe are processed using a signal processing program to yield radial profiles of the void fraction, bubble velocity, and interfacial area concentration. The velocity measurements of the liquid-phase are performed using a state-of-the-art Particle Image Velocimetry (PIV) system. The raw PIV images are acquired using fluorescent particles and an optical filtration device. Image processing is used to remove noise in the raw PIV images. The statistical cross correlation is introduced to determine the axial velocity field and turbulence intensity of the liquid-phase. Measurements are currently being performed at z/D = 32 to provide a more complete data set. These data can be used for computational fluid dynamic model development and validation. (authors)

  20. Air quality modelling : effects of emission reductions on concentrations of particulate matter

    NASA Astrophysics Data System (ADS)

    Girault, L.; Roustan, Y.; Seigneur, C.

    2012-04-01

    Atmospheric particulate matter (PM) has adverse effects on human health. PM acts primarily on respiratory and cardiovascular (due to their small size they can penetrate deep into the lungs), but they are also known effects on the skin. In France, the "Particulate Plan" - developed as part of the second National Environmental Health Plan - aims to reduce by 30% fine PM (noted PM2.5because these particles have an aerodynamic diameter of 2.5 micrometers or less) by 2015. A recent study by Airparif (the organization in charge of monitoring air quality in the Paris region, the Île-de-France) and LSCE (Laboratory of climate and the environmental science, France) has allowed, through a large measurement campaign conducted between 2009 and 2011, to quantify the proportion of PM produced in Île-de-France and those transported from the surrounding areas. The study by numerical modelling of air pollution presented here complements these results by investigating future emission scenarios. The CEREA develops and uses an air quality model which simulates the concentrations of pollutants from an emission inventory, meteorological data and boundary conditions of the area studied. After an evaluation of simulation results for the year 2005, the model is used to assess the effects of various scenarios of reductions in NOx and NH3 emissions on the concentrations of PM2.5in Île-de-France. The effects of the controls on the local pollution and the long-range pollution are considered separately. For each emitted species, three scenarios of emission reductions are identified: an emission reduction at the local level (Île-de-France), a reduction at the regional scale (France) and a reduction at the continental scale (across Europe). In each case, a 15% reduction is applied. The comparison of the results allows us to assess the respective contributions of local emissions and long-range transport to PM2.5 concentrations. For instance, the reduction of NOx emissions in Europe leads to a

  1. Species measurements in a hypersonic, hydrogen-air, combustion wake

    SciTech Connect

    Skinner, K.A.; Stalker, R.J.

    1996-09-01

    A continuously sampling, time-of-flight mass spectrometer has been used to measure relative species concentrations in a two-dimensional, hydrogen-air combustion wake at mainstream Mach numbers exceeding 5. The experiments, in a free piston shock tunnel, yielded distributions of hydrogen, oxygen, nitrogen, water, and nitric oxide at stagnation enthalpies ranging from 5.6 MJ/kg to 12.2 MJ/kg and at a distance of approximately 100s times the thickness of the initial hydrogen jet. The amount of hydrogen mixed in stoichiometric proportions was approximately independent of the stagnation enthalpy, despite the fact that the proportion of hydrogen in the wake was increased with stagnation enthalpy. Roughly 50% of the mixed hydrogen underwent combustion at the highest enthalpy. The proportion of hydrogen reacting to water could be approximately predicted using reaction rates based on mainstream temperatures.

  2. Species measurements in a hypersonic, hydrogen-air, combustion wake

    NASA Technical Reports Server (NTRS)

    Skinner, K. A.; Stalker, R. J.

    1995-01-01

    A continuously sampling, time-of-flight mass spectrometer has been used to measure relative species concentrations in a two-dimensional, hydrogen-air combustion wake at mainstream Mach numbers exceeding 5. The experiments, which were conducted in a free piston shock tunnel, yielded distributions of hydrogen, oxygen, nitrogen, water and nitric oxide at stagnation enthalpies ranging from 5.6 MJ kg(exp -1) to 1.2 MJ kg(exp -1) and at a distance of approximately 100 times the thickness of the initial hydrogen jet. The amount of hydrogen that was mixed in stoichiometric proportions was approximately independent of the stagnation enthalpy, in spite of the fact that the proportion of hydrogen in the wake increased with stagnation enthalpy. Roughly 50 percent of the mixed hydrogen underwent combustion at the highest enthalpy. The proportion of hydrogen reacting to water could be approximately predicted using reaction rates based on mainstream temperatures.

  3. A critical review of reported air concentrations of organic compounds in aircraft cabins.

    PubMed

    Nagda, N L; Rector, H E

    2003-09-01

    This paper presents a review and assessment of aircraft cabin air quality studies with measured levels of volatile and semivolatile organic compounds (VOCs and SVOCs). VOC and SVOC concentrations reported for aircraft cabins are compared with those reported for residential and office buildings and for passenger compartments of other types of transportation. An assessment of measurement technologies and quality assurance procedures is included. The six studies reviewed in the paper range in coverage from two to about 30 flights per study. None of the monitored flights included any unusual or episodic events that could affect cabin air quality. Most studies have used scientifically sound methods for measurements. Study results indicate that under routine aircraft operations, contaminant levels in aircraft cabins are similar to those in residential and office buildings, with two exceptions: (1). levels of ethanol and acetone, indicators of bioeffluents and chemicals from consumer products are higher in aircraft than in home or office environments, and (2). levels of certain chlorinated hydrocarbons and fuel-related contaminants are higher in residential/office buildings than in aircraft. Similarly, ethanol and acetone levels are higher in aircraft than in other transportation modes but the levels of some pollutants, such as m-/p-xylenes, tend to be lower in aircraft.

  4. Laser Sounder Technique for Remotely Measuring Atmospheric CO2 Concentrations

    NASA Astrophysics Data System (ADS)

    Abshire, J. B.; Collatz, G. J.; Sun, X.; Riris, H.; Andrews, A. E.; Krainak, M.

    2001-12-01

    We describe progress in developing a lidar technique for the remote measurement of the tropospheric CO2 concentrations. Our goal is to demonstrate a technique and technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft at the few ppm level, with a capability of scaling to permit global CO2 measurements from orbit. Accurate remote sensing measurements of CO2 mixing ratio from aircraft and space appear difficult. Potential error sources include possible interferences from other trace gas species, the effects of clouds and aerosols in the path, and variability in dry air density caused by pressure or topographic changes. Some potential instrumental errors include frequency drifts in the transmitter and sensitivity drifts in the receiver. High signal-to-noise ratios are needed for estimates at the few ppm level. We are developing a laser sounder approach as a candidate for these measurements. It uses 3 laser transmitters to permit simultaneous measurement of CO2 and O2 extinction, and aerosol backscatter at 1064 nm in the same atmospheric path. It directs the co-aligned laser beams from the lidar toward nadir, and measures the energy of the laser backscatter from land and water surfaces. During each measurement period, the two narrow linewidth lasers are rapidly tuned on and off the selected CO2 and O2 absorption lines. The receiver records and averages the energies of the laser echoes. The column extinction and column densities of both CO2 and O2 are estimated via the differential absorption lidar technique. For the on-line wavelength, the side of the gas absorption line is used, which weights its measurements to 0-4 km in the troposphere. Simultaneous measurements of O2 column abundance are made using an identical approach using an O2 line near 770 nm. Atmospheric baskscatter profiles are measured with the 1064 nm channel, which permits identifying and excluding measurements containing clouds or aerosols backscatter

  5. EFFECTS OF METAL COMPONENTS IN CONCENTRATED AMBIENT AIR PARTICLES ON PULMONARY INJURY

    EPA Science Inventory

    EFFECTS OF METAL COMPONENTS IN CONCENTRATED AMBIENT AIR PARTICLES ON PULMONARY INJURY. Yuh-Chin Huang, Jackie Stonehuerner, Jackie Carter, Andrew J. Ghio, Robert B. Devlin. NHEERL, US EPA, RTP, NC.
    The mechanisms for cardiopulmonary morbidity associated with exposure to air po...

  6. Diagnostic significance of nitric oxide concentrations in exhaled air from the airways in allergic rhinitis patients

    PubMed Central

    Krzych-Fałta, Edyta; Samoliński, Bolesław K; Zalewska, Marta

    2016-01-01

    Introduction The effect of nitric oxide (NO) on the human body is very important due its physiological regulation of the following functions of airways: modulation of ciliary movement and maintenance of sterility in sinuses. Aim To evaluate the diagnostic significance of NO concentrations in exhaled air from the upper and lower airways in patients diagnosed with allergic rhinitis (AR). Material and methods The subjects included in the study were a group of 30 people diagnosed with sensitivity to environmental allergens and a control group consisting of 30 healthy subjects. The measurement of NO in the air exhaled from the lower and upper airways was performed using an on-line method by means of Restricted Exhaled Breath (REB), as well as using the measurement procedure (chemiluminescence) set out in the guidelines prepared in 2005 by the American Thoracic Society and the European Respiratory Society. Results In the late phase of the allergic reaction, higher values of the level of exhaled NO concentration from the lower airways were observed in the groups of subjects up to the threshold values of 25.17 ppb in the group of subjects with year-round allergic rhinitis and 21.78 ppb in the group with diagnosed seasonal allergic rhinitis. The difference in the concentration of NO exhaled from the lungs between the test group and the control group in the 4th h of the test was statistically significant (p = 0.045). Conclusions Exhaled NO should be considered as a marker of airway inflammation. It plays an important role in the differential diagnosis of allergy. PMID:27279816

  7. Measure Guideline: Air Sealing Attics in Multifamily Buildings

    SciTech Connect

    Otis, C.; Maxwell, S.

    2012-06-01

    This Building America Measure Guideline is intended for owners, builders, contractors, homeowners, and other stakeholders in the multifamily building industry, and focuses on challenges found in existing buildings for a variety of housing types. It explains why air sealing is desirable, explores related health and safety issues, and identifies common air leakage points in multifamily building attics. In addition, it also gives an overview of materials and techniques typically used to perform air sealing work.

  8. Measure Guideline. Air Sealing Attics in Multifamily Buildings

    SciTech Connect

    Otis, Casey; Maxwell, Sean

    2012-06-01

    This Building America Measure Guideline is intended for owners, builders, contractors, homeowners, and other stakeholders in the multifamily building industry, and focuses on challenges found in existing buildings for a variety of housing types. It explains why air sealing is desirable, explores related health and safety issues, and identifies common air leakage points in multifamily building attics. In addition, it also gives an overview of materials and techniques typically used to perform air sealing work.

  9. Thermodynamic correction of particle concentrations measured by underwing probes on fast flying aircraft

    NASA Astrophysics Data System (ADS)

    Weigel, R.; Spichtinger, P.; Mahnke, C.; Klingebiel, M.; Afchine, A.; Petzold, A.; Krämer, M.; Costa, A.; Molleker, S.; Jurkat, T.; Minikin, A.; Borrmann, S.

    2015-12-01

    Particle concentration measurements with underwing probes on aircraft are impacted by air compression upstream of the instrument body as a function of flight velocity. In particular for fast-flying aircraft the necessity arises to account for compression of the air sample volume. Hence, a correction procedure is needed to invert measured particle number concentrations to ambient conditions that is commonly applicable for different instruments to gain comparable results. In the compression region where the detection of particles occurs (i.e. under factual measurement conditions), pressure and temperature of the air sample are increased compared to ambient (undisturbed) conditions in certain distance away from the aircraft. Conventional procedures for scaling the measured number densities to ambient conditions presume that the particle penetration speed through the instruments' detection area equals the aircraft speed (True Air Speed, TAS). However, particle imaging instruments equipped with pitot-tubes measuring the Probe Air Speed (PAS) of each underwing probe reveal PAS values systematically below those of the TAS. We conclude that the deviation between PAS and TAS is mainly caused by the compression of the probed air sample. From measurements during two missions in 2014 with the German Gulfstream G-550 (HALO - High Altitude LOng range) research aircraft we develop a procedure to correct the measured particle concentration to ambient conditions using a thermodynamic approach. With the provided equation the corresponding concentration correction factor ξ is applicable to the high frequency measurements of each underwing probe which is equipped with its own air speed sensor (e.g. a pitot-tube). ξ-values of 1 to 0.85 are calculated for air speeds (i.e. TAS) between 60 and 260 m s-1. From HALO data it is found that ξ does not significantly vary between the different deployed instruments. Thus, for the current HALO underwing probe configuration a parameterisation of

  10. Volatile organic compounds in indoor air: A review ofconcentrations measured in North America since 1990

    SciTech Connect

    ATHodgson@lbl.gov

    2003-04-01

    Central tendency and upper limit concentrations of volatile organic compounds (VOCs) measured in indoor air are summarized and reviewed. Data were obtained from published cross-sectional studies of residential and office buildings conducted in North America from 1990through the present. VOC concentrations in existing residences reported in 12 studies comprise the majority of the data set. Central tendency and maximum concentrations are compared between new and existing residences and between existing residences and office buildings. Historical changes in indoor VOC concentrations since the Clean Air Act Amendments of 1990 are explored by comparing the current data set with two published reviews of previous data obtained primarily in the 1980s. These historical comparisons suggest average indoor concentrations of some toxic air contaminants, such as 1,1,1-trichloroethane have decreased.

  11. Nitric oxide density measurements in air and air/fuel nanosecond pulse discharges by laser induced fluorescence

    NASA Astrophysics Data System (ADS)

    Uddi, M.; Jiang, N.; Adamovich, I. V.; Lempert, W. R.

    2009-04-01

    Laser induced fluorescence is used to measure absolute nitric oxide concentrations in air, methane-air and ethylene-air non-equilibrium plasmas, as a function of time after initiation of a single pulse, 20 kV peak voltage, 25 ns pulse duration discharge. A mixture of NO and nitrogen with known composition (4.18 ppm NO) is used for calibration. Peak NO density in air at 60 Torr, after a single pulse, is ~8 × 1012 cm-3 (~4.14 ppm) occurring at ~250 µs after the pulse, with decay time of ~16.5 ms. Peak NO atom mole fraction in a methane-air mixture with equivalence ratio of phiv = 0.5 is found to be approximately equal to that in air, with approximately the same rise and decay rate. In an ethylene-air mixture (also with equivalence ratio of phiv = 0.5), the rise and decay times are comparable to air and methane-air, but the peak NO concentration is reduced by a factor of approximately 2.5. Spontaneous emission measurements show that excited electronic states N2(C 3Π) and NO(A 2Σ) in air at P = 60 Torr decay within ~20 ns and ~1 µs, respectively. Kinetic modelling calculations incorporating air plasma kinetics complemented with the GRI Mech 3.0 hydrocarbon oxidation mechanism are compared with the experimental data using three different NO production mechanisms. It is found that NO concentration rise after the discharge pulse is much faster than predicted by Zel'dovich mechanism reactions, by two orders of magnitude, but much slower compared with reactions of electronically excited nitrogen atoms and molecules, also by two orders of magnitude. It is concluded that processes involving long lifetime (~100 µs) metastable states, such as N2(X 1Σ,v) and O2(b 1Σ), formed by quenching of the metastable N2(A 3Σ) state by ground electronic state O2, may play a dominant role in NO formation. NO decay, in all cases, is found to be dominated by the reverse Zel'dovich reaction, NO + O → N + O2, as well as by conversion into NO2 in a reaction of NO with ozone.

  12. Background concentrations of individual and total volatile organic compounds in residential indoor air of Schleswig-Holstein, Germany.

    PubMed

    Hippelein, Martin

    2004-09-01

    During a monitoring campaign concentrations of volatile organic compounds (VOCs) were measured in indoor air of 79 dwellings where occupants had not complained about health problems or unpleasant odour. Parameters monitored were the individual concentration of 68 VOCs and the total concentration of all VOCs inside the room. VOCs adsorbed by Tenax TA were then analysed by means of thermal desorption, gas chromatography and mass spectrometry. The analytical procedure and quantification was done according to the recommendation of the ECA-IAQ Working Group 13 which gave a definition of the total volatile organic compound (TVOC) concentration. Using this recommendation TVOC-concentrations ranged between 33 and 1600 microg m(-3) with a median of 289 microg m(-3). Compounds found in every sample and with the highest concentrations were 2-propanol, alpha-pinene and toluene. Save for a few samples, all concentrations measured have been a factor 2 to 10 lower, compared to data from similar studies. Only a few terpenes and aldehydes were found exceeding published reference data or odour threshold concentrations. However, it has been found that sampling and analysing methods do have a considerable impact on the results, making direct comparisons of studies somewhat questionable. 47% of all samples revealed concentrations exceeding the threshold value of 300 microg TVOC m(-3) set by the German Federal Environmental Agency as a target for indoor air quality. Using the TVOC concentration as defined in the ECA-IAQ methodology is instrumental in assessing exposure to VOCs and identifying sources of VOCs. The background concentrations determined in this study can be used to discuss and interpret target values for individual and total volatile organic compounds in indoor air.

  13. Effect of poverty on the relationship between personal exposures and ambient concentrations of air pollutants in Ho Chi Minh City

    NASA Astrophysics Data System (ADS)

    Mehta, Sumi; Sbihi, Hind; Dinh, Tuan Nguyen; Xuan, Dan Vu; Le Thi Thanh, Loan; Thanh, Canh Truong; Le Truong, Giang; Cohen, Aaron; Brauer, Michael

    2014-10-01

    Socioeconomic factors often affect the distribution of exposure to air pollution. The relationships between health, air pollution, and poverty potentially have important public health and policy implications, especially in areas of Asia where air pollution levels are high and income disparity is large. The objective of the study was to characterize the levels, determinants of exposure, and relationships between children personal exposures and ambient concentrations of multiple air pollutants amongst different socioeconomic segments of the population of Ho Chi Minh City, Vietnam. Using repeated (N = 9) measures personal exposure monitoring and determinants of exposure modeling, we compared daily average PM2.5, PM10, PM2.5 absorbance and NO2 concentrations measured at ambient monitoring sites to measures of personal exposures for (N = 64) caregivers of young children from high and low socioeconomic groups in two districts (urban and peri-urban), across two seasons. Personal exposures for both PM sizes were significantly higher among the poor compared to non-poor participants in each district. Absolute levels of personal exposures were under-represented by ambient monitors with median individual longitudinal correlations between personal exposures and ambient concentrations of 0.4 for NO2, 0.6 for PM2.5 and PM10 and 0.7 for absorbance. Exposures of the non-poor were more highly correlated with ambient concentrations for both PM size fractions and absorbance while those for NO2 were not significantly affected by socioeconomic position. Determinants of exposure modeling indicated the importance of ventilation quality, time spent in the kitchen, air conditioner use and season as important determinant of exposure that are not fully captured by the differences in socioeconomic position. Our results underscore the need to evaluate how socioeconomic position affects exposure to air pollution. Here, differential exposure to major sources of pollution, further influenced by

  14. USING THE AIR QUALITY MODEL TO ANALYZE THE CONCENTRATIONS OF AIR TOXICS OVER THE CONTINENTAL U.S.

    EPA Science Inventory

    The U.S. Environmental Protection Agency is examining the concentrations and deposition of hazardous air pollutants (HAPs), which include a large number of chemicals, ranging from non reactive (i.e. carbon tetrachloride) to reactive (i.e. formaldehyde), exist in gas, aqueous, and...

  15. Proton dose calculation based on in-air fluence measurements.

    PubMed

    Schaffner, Barbara

    2008-03-21

    Proton dose calculation algorithms--as well as photon and electron algorithms--are usually based on configuration measurements taken in a water phantom. The exceptions to this are proton dose calculation algorithms for modulated scanning beams. There, it is usual to measure the spot profiles in air. We use the concept of in-air configuration measurements also for scattering and uniform scanning (wobbling) proton delivery techniques. The dose calculation includes a separate step for the calculation of the in-air fluence distribution per energy layer. The in-air fluence calculation is specific to the technique and-to a lesser extent-design of the treatment machine. The actual dose calculation uses the in-air fluence as input and is generic for all proton machine designs and techniques. PMID:18367787

  16. Concentrations in air of organobromine, organochlorine and organophosphate flame retardants in Toronto, Canada

    NASA Astrophysics Data System (ADS)

    Shoeib, Mahiba; Ahrens, Lutz; Jantunen, Liisa; Harner, Tom

    2014-12-01

    Concentrations of organobromine (BFRs), organochlorine (CFRs) and organophosphate esters flame retardants and plasticizers (PFRs) in air were monitored for over one year at an urban site in Toronto, Canada during 2010-2011. The mean value for polybrominated diphenyl ethers (BDEs) (gas + particle phase) was 38 pg/m3 with BDE-47 and BDE-99 as the dominant congeners. The mean concentrations in air for ∑non-BDE (BFRs and CFRs), was 9.6 pg/m3 - about four times lower than the BDEs. The brominated FRs: TBP-AE, BTBPE, EH-TBB, BEH-TEBP and the chlorinated syn- and anti-DP were detected frequently, ranging from 87% to 96%. Highest concentrations in air among all flame retardant classes were observed for the Σ-PFRs. The yearly mean concentration in air for ΣPFRs was 2643 pg/m3 with detection frequency higher than 80%. Except for TBP-AE and b- DBE-DBCH, non-BDEs (BFRs, CFRs and PFRs) were mainly associated with the particle phase. BDE concentrations in air were positively correlated with temperature indicating that volatilization from local sources was an important factor controlling levels in air. This correlation did not hold for most BFRs, CFRs and PFRs which were mainly on particles. For these compounds, air concentrations in Toronto are likely related to emissions from point sources and advective inputs. This study highlights the importance of urban air monitoring for FRs. Urban air can be considered a sentinel for detecting changes in the use and application of FRs in commercial products.

  17. Air concentrations and wet deposition of major inorganic ions at five non-urban sites in China, 2001-2003

    NASA Astrophysics Data System (ADS)

    Aas, Wenche; Shao, Min; Jin, Lei; Larssen, Thorjørn; Zhao, Dawei; Xiang, Renjun; Zhang, Jinhong; Xiao, Jinsong; Duan, Lei

    Air and precipitation measurements at five sites were undertaken from 2001 to 2003 in four different provinces in China, as part of the acid rain monitoring program IMPACTS. The sites were located in Tie Shan Ping (TSP) in Chongqing, Cai Jia Tang (CJT) in Hunan, Lei Gong Shan (LGS) and Liu Chong Guan (LCG) in Guizhou and Li Xi He (LXH) in Guangdong. The site characteristics are quite varied with TSP and LCG located relatively near big cites while the three others are situated in more regionally representative areas. The distances to urban centres are reflected in the air pollution concentrations, with annual average concentrations of SO 2 ranging from 0.5 to above 40 μg S m -3. The main components in the airborne particles are (NH 4) 2SO 4 and CaSO 4. Reduced nitrogen has a considerably higher concentration level than oxidised nitrogen, reflecting the high ammonia emissions from agriculture. The gas/particle ratio for the nitrogen compounds is about 1:1 at all the three intensive measurement sites, while for sulphur it varies from 2.5 to 0.5 depending on the distance to the emission sources. As in air, the predominant ions in precipitation are sulphate, calcium and ammonium. The volume weighted annual concentration of sulphate ranges from about 70 μeq l -1 at the most rural site (LGS) to about 200 μeq l -1 at TSP and LCG. The calcium concentration ranges from 25 to 250 μeq l -1, while the total nitrogen concentration is between 30 and 150 μeq l -1; ammonium is generally twice as high as nitrate. China's acid rain research has traditionally been focused on urban sites, but these measurements show a significant influence of long range transported air pollutants to rural areas in China. The concentration levels are significantly higher than seen in most other parts of the world.

  18. 40 CFR 90.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Intake air flow measurement specifications. 90.416 Section 90.416 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test Procedures §...

  19. Effect of the implosion and demolition of a hospital building on the concentration of fungi in the air.

    PubMed

    Barreiros, Gloria; Akiti, Tiyomi; Magalhães, Ana Cristina Gouveia; Nouér, Simone A; Nucci, Marcio

    2015-12-01

    Building renovations increase the concentration of Aspergillus conidia in the air. In 2010, one wing of the hospital building was imploded due to structural problems. To evaluate the impact of building implosion on the concentration of fungi in the air, the demolition was performed in two phases: mechanical demolition of 30 m of the building, followed by implosion of the wing. Patients at high risk for aspergillosis were placed in protected wards. Air sampling was performed during mechanical demolition, on the day of implosion and after implosion. Total and specific fungal concentrations were compared in the different areas and periods of sampling, using the anova test. The incidence of IA in the year before and after implosion was calculated. The mean concentration of Aspergillus increased during mechanical demolition and on the day of implosion. However, in the most protected areas, there was no significant difference in the concentration of fungi. The incidence of invasive aspergillosis (cases per 1000 admissions) was 0.9 in the 12 months before, 0.4 during, and 0.5 in the 12 months after mechanical demolition (P > 0.05). Continuous monitoring of the quality of air and effective infection control measures are important to minimize the impact of building demolition. PMID:26449634

  20. Optical Air Flow Measurements in Flight

    NASA Technical Reports Server (NTRS)

    Bogue, Rodney K.; Jentink, Henk W.

    2004-01-01

    This document has been written to assist the flight-test engineer and researcher in using optical flow measurements in flight applications. The emphasis is on describing tradeoffs in system design to provide desired measurement performance as currently understood. Optical system components are discussed with examples that illustrate the issues. The document concludes with descriptions of optical measurement systems designed for a variety of applications including aeronautics research, airspeed measurement, and turbulence hazard detection. Theoretical discussion is minimized, but numerous references are provided to supply ample opportunity for the reader to understand the theoretical underpinning of optical concepts.

  1. Real-time precision concentration measurement for flowing liquid solutions

    NASA Astrophysics Data System (ADS)

    Krishna, V.; Fan, C. H.; Longtin, J. P.

    2000-10-01

    The precise, real-time measurement of liquid concentration is important in fundamental research, chemical analysis, mixing processes, and manufacturing, e.g., in the food and semiconductor industries. This work presents a laser-based, noninvasive technique to measure concentration changes of flowing liquids in real time. The essential components in the system include a 5 mW laser diode coupled to a single-mode optical fiber, a triangular optical cell, and a high-resolution beam position sensor. The instrument provides a large range of concentration measurement, typically 0%-100% for binary liquid mixtures, while providing a resolution on the order of 0.05% concentration or better. The experimental configuration is small, reliable, and inexpensive. Results are presented for NaCl and MgCl2 aqueous solutions with concentrations ranging from 0% to 25%, with very good agreement found between measured and true concentrations.

  2. [Relationship of the ambient air concentrations of chemical substances to the spread of allergic diseases in children].

    PubMed

    Galeev, K A; Khakimova, R F

    2002-01-01

    The role of some ingredients that contaminate the ambient air in the occurrence and development of allergic diseases was studied. The closest relationships were found between the concentrations of hydrogen sulfide and the prevalence of eczema (rxy +/- m = 0.48 +/- 0.15). There was a direct correlation between the concentrations of each ingredient and the incidence of neurodermitis among children. The correlation between the summarized concentrations of ingredients and the incidence of bronchial asthma among children was rxy +/- m = 0.71 +/- 0.19. The findings serves as the basis for elaborating measures to reduce ecological tension and the incidence of allergic diseases in children. PMID:12380496

  3. Airborne measurements of air pollution chemistry and transport. 1: Initial survey of major air basins in California

    NASA Technical Reports Server (NTRS)

    Gloria, H. R.; Pitts, J. N., Jr.; Behar, J. V.; Bradburn, G. A.; Reinisch, R. F.; Zafonte, L.

    1972-01-01

    An instrumented aircraft has been used to study photochemical air pollution in the State of California. Simultaneous measurements of the most important chemical constituents (ozone, total oxidant, hydrocarbons, and nitrogen oxides, as well as several meteorological variables) were made. State-of-the-art measurement techniques and sampling procedures are discussed. Data from flights over the South Coast Air Basin, the San Francisco Bay Area, the San Joaquin Valley, the Santa Clara and Salinas Valleys, and the Pacific Ocean within 200 miles of the California coast are presented. Pollutants were found to be concentrated in distant layers up to at least 18,000 feet. In many of these layers, the pollutant concentrations were much higher than at ground level. These findings bring into serious question the validity of the present practice of depending solely on data from ground-based monitoring stations for predictive models.

  4. MTBE concentrations in ambient air in the vicinity of service stations

    NASA Astrophysics Data System (ADS)

    Vainiotalo, Sinikka; Peltonen, Yrjö; Pfäffli, Pirkko

    Ambient air concentrations of methyl tertiary-butyl ether (MTBE) were monitored in the vicinity of two self-service stations in May-June and October, 1995. These stations (one urban and one roadside) were located in southwestern Finland and were equipped with "stage I" vapour recovery systems. All the gasoline blends dispensed during the study (95, 98 and 99 RON) contained 11% MTBE. The measurements were carried out 24 h day -1 at stationary sampling points located at the four main compass points on the service station perimeter (about 50 m from the centre of the forecourt). The air samples were collected in charcoal tubes and analysed in laboratory by gas chromatography using mass-selective detection. The concentrations in individual samples ranged from 0.5 to 121 μg m -3, and the highest daily concentrations were usually obtained at the downwind sampling points. The arithmetic mean concentrations for each of the four-day sampling periods were: 7.5 μg m -3 (station 1/May-June), 4.1 μg/m 3 (station 1/October), 12.4 μg m -3 (station 2/June) and 14.1 μg m -3 (station 2/October). The mean concentrations measured in the centre of the pump island (only daytime sampling) ranged from 247 to 1347 μg m -3. The levels of MTBE are station-specific and dependent on many factors, such as volumes of gasolines sold, wind speed, exhaust emissions from passing traffic, and deliveries of gasoline to the station. The mean wind speeds were between 0.7 and 1.5 m s -1, and the temperatures were above 22°C in summer and about 10°C in October. The volume of gasoline sold at the urban service station, station 2, was twice that at the roadside service station, station 1. There was one road with high traffic density adjacent to station 1 and two such roads at station 2. Gasoline was delivered twice to station 1 and 3 times to station 2 during the study.

  5. Measurement of total reduced sulfur compounds in ambient air

    SciTech Connect

    McQuaker, N.R.; Rajala, G.E.; Pengilly, D.

    1986-05-01

    Methods for the determination of total reduced sulfur (TRS) compounds in the ambient air based on coulometric detection (Philips Model PW 9700 analyzer) and thermal oxidation followed by detection using pulsed fluorescence (Teco Model 43 analyzer) have been evaluated. Analytical response factors, relative to H/sub 2/S, were determined for both the individual TRS compounds and compounds such as terpenes and carbonyl sulfide that may be a potential source of interference. The results for COS and terpenes indicate that in a typical monitoring situation normally encountered concentrations of these compounds are not expected to cause significant measurement bias. The results for the individual TRS compounds indicate that while variations in TRS composition are not a factor in assessing measurement bias for the thermal oxidation/pulsed fluorescence method, they are a factor for the Philips coulometric method; i.e., increasing positive measurement bias maybe introduced as the TRS composition shifts toward relatively less H/sub 2/S. Philips-Teco comparison data collected at a single site in the vicinity of three operating kraft pupil mills are compatible with these expectations. 8 references, 1 figure, 3 tables.

  6. Concentrated ambient air particles induce vasoconstriction of small pulmonary arteries in rats.

    PubMed Central

    Batalha, Joao R F; Saldiva, Paulo H N; Clarke, Robert W; Coull, Brent A; Stearns, Rebecca C; Lawrence, Joy; Murthy, G G Krishna; Koutrakis, Petros; Godleski, John J

    2002-01-01

    The objective of this study was to determine whether short-term exposures to concentrated ambient particles (CAPs) alter the morphology of small pulmonary arteries in normal rats and rats with chronic bronchitis (CB). Sprague-Dawley male rats were exposed to CAPs, using the Harvard Ambient Particle Concentrator, or to particle-free air (sham) under identical conditions during 3 consecutive days (5 hr/day) in six experimental sets. CB was induced by exposure to 276 +/- 9 ppm of sulfur dioxide (5 hr/day, 5 days/week, 6 weeks). Physicochemical characterization of CAPs included measurements of particle mass, size distribution, and composition. Rats were sacrificed 24 hr after the last CAPs exposure. Histologic slides were prepared from random sections of lung lobes and coded for blinded analysis. The lumen/wall area (L/W) ratio was determined morphometrically on transverse sections of small pulmonary arteries. When all animal data (normal and CB) were analyzed together, the L/W ratios decreased as concentrations of fine particle mass, silicon, lead, sulfate, elemental carbon, and organic carbon increased. In separate univariate analyses of animal data, the association for sulfate was significant only in normal rats, whereas silicon was significantly associated in both CB and normal rats. In multivariate analyses including all particle factors, the association with silicon remained significant. Our results indicate that short-term CAPs exposures (median, 182.75 micro g/m3; range, 73.50-733.00 micro g/m3) can induce vasoconstriction of small pulmonary arteries in normal and CB rats. This effect was correlated with specific particle components and suggests that the pulmonary vasculature might be an important target for ambient air particle toxicity. PMID:12460797

  7. AIR INFILTRATION MEASUREMENTS USING TRACER GASES: A LITERATURE REVIEW

    EPA Science Inventory

    The report gives results of a literature review of air filtration measurements using tracer gases, including sulfur hexafluoride, hydrogen, carbon monoxide, carbon dioxide, nitrous oxide, and radioactive argon and krypton. Sulfur hexafluoride is the commonest tracer gas of choice...

  8. Evaluation of ambient air concentrations of polycyclic aromatic hydrocarbons in Germany from 1990 to 1998.

    PubMed

    Fertmann, Regina; Tesseraux, Irene; Schümann, Michael; Neus, Hermann

    2002-03-01

    All available polycyclic aromatic hydrocarbon (PAH) concentration data in ambient air obtained over the past 10 years in Germany were evaluated to clarify whether it is justified to use benzo(a)pyrene (BaP) as a marker compound for the total PAH exposure. The data basis comprises annual mean concentrations from 1990 to 1998 supplied by the emission protection authorities of the federal states with additional information on the region, year and site of measurement. The data are very heterogeneous with respect to sample size, the number of individual PAHs analyzed, place of origin and year. Nine of 25 individual compounds with sufficient sample size (74concentration data of BaA, BeP, BaP, DBA, BghiP, COR, BbF, BkF and INP are not normally distributed and demonstrate great variability. Location, East-West differences persisting after the German reunion and time characterize the distributive patterns, e.g., from 1991 to 1997, a significant decrease in BaP could be determined based on the data from North Rhine-Westphalia (1991, N=51, median 1.6 ng/m(3); 1997, N=45, median 0.7 ng/m(3); Pconcentrations in the new federal states in the East (N=80, median 2.2 ng/m(3)) are about twice as high compared to the ones in the old federal states in the West (N=438, median 1.1 ng/m(3); Pmeasurements taken at sites characterized by traffic (1.8 ng/m(3)), industrial (1.3 ng/m(3)) or urban environment (1.3 ng/m(3)) rank significantly higher compared to measurements taken at rural sites (0.92 ng/m(3); P

  9. Spatial & temporal variations of PM10 and particle number concentrations in urban air.

    PubMed

    Johansson, Christer; Norman, Michael; Gidhagen, Lars

    2007-04-01

    The size of particles in urban air varies over four orders of magnitude (from 0.001 microm to 10 microm in diameter). In many cities only particle mass concentrations (PM10, i.e. particles <10 microm diameter) is measured. In this paper we analyze how differences in emissions, background concentrations and meteorology affect the temporal and spatial distribution of PM10 and total particle number concentrations (PNC) based on measurements and dispersion modeling in Stockholm, Sweden. PNC at densely trafficked kerbside locations are dominated by ultrafine particles (<0.1 microm diameter) due to vehicle exhaust emissions as verified by high correlation with NOx. But PNC contribute only marginally to PM10, due to the small size of exhaust particles. Instead wear of the road surface is an important factor for the highest PM10 concentrations observed. In Stockholm, road wear increases drastically due to the use of studded tires and traction sand on streets during winter; up to 90% of the locally emitted PM10 may be due to road abrasion. PM10 emissions and concentrations, but not PNC, at kerbside are controlled by road moisture. Annual mean urban background PM10 levels are relatively uniformly distributed over the city, due to the importance of long range transport. For PNC local sources often dominate the concentrations resulting in large temporal and spatial gradients in the concentrations. Despite these differences in the origin of PM10 and PNC, the spatial gradients of annual mean concentrations due to local sources are of equal magnitude due to the common source, namely traffic. Thus, people in different areas experiencing a factor of 2 different annual PM10 exposure due to local sources will also experience a factor of 2 different exposure in terms of PNC. This implies that health impact studies based solely on spatial differences in annual exposure to PM10 may not separate differences in health effects due to ultrafine and coarse particles. On the other hand

  10. Spatial & temporal variations of PM10 and particle number concentrations in urban air.

    PubMed

    Johansson, Christer; Norman, Michael; Gidhagen, Lars

    2007-04-01

    The size of particles in urban air varies over four orders of magnitude (from 0.001 microm to 10 microm in diameter). In many cities only particle mass concentrations (PM10, i.e. particles <10 microm diameter) is measured. In this paper we analyze how differences in emissions, background concentrations and meteorology affect the temporal and spatial distribution of PM10 and total particle number concentrations (PNC) based on measurements and dispersion modeling in Stockholm, Sweden. PNC at densely trafficked kerbside locations are dominated by ultrafine particles (<0.1 microm diameter) due to vehicle exhaust emissions as verified by high correlation with NOx. But PNC contribute only marginally to PM10, due to the small size of exhaust particles. Instead wear of the road surface is an important factor for the highest PM10 concentrations observed. In Stockholm, road wear increases drastically due to the use of studded tires and traction sand on streets during winter; up to 90% of the locally emitted PM10 may be due to road abrasion. PM10 emissions and concentrations, but not PNC, at kerbside are controlled by road moisture. Annual mean urban background PM10 levels are relatively uniformly distributed over the city, due to the importance of long range transport. For PNC local sources often dominate the concentrations resulting in large temporal and spatial gradients in the concentrations. Despite these differences in the origin of PM10 and PNC, the spatial gradients of annual mean concentrations due to local sources are of equal magnitude due to the common source, namely traffic. Thus, people in different areas experiencing a factor of 2 different annual PM10 exposure due to local sources will also experience a factor of 2 different exposure in terms of PNC. This implies that health impact studies based solely on spatial differences in annual exposure to PM10 may not separate differences in health effects due to ultrafine and coarse particles. On the other hand

  11. Absolute concentration measurements inside a jet plume using video digitization

    NASA Astrophysics Data System (ADS)

    Vauquelin, O.

    An experimental system based on digitized video image analysis is used to measure the local value of the concentration inside a plume. Experiments are carried out in a wind-tunnel for a smoke-seeded turbulent jet plume illuminated with a laser beam. Each test is filmed, subsequently video images are digitized and analysed in order to determine the smoke absolute concentration corresponding to each pixel gray level. This non-intrusive measurement technique is first calibrated and different laws connecting gray level to concentration are established. As a first application, concentration measurements are made inside a turbulent jet plume and compared with measurements conducted using a classic gas analysis method. We finally present and discuss the possibilities offered for the measurements of absolute concentration fluctuations.

  12. MEASUREMENT OF HYDROPEROXIDES DURING THE TEXAS 2000 AIR QUALITY STUDY.

    SciTech Connect

    ZHENG,J.; ALAOUIE,A.; WEINSTEIN-LLOYD,J.B.; SPRINGSTON,S.R.; NUNNERMACKER,L.J.; LEE,Y.N.; BRECHTEL,F.; KLEINMAN,L.; DAUM,P.

    2002-01-17

    Hydroperoxides are important atmospheric oxidants. They are responsible for most of the oxidation of aqueous-phase SO{sub 2} to sulfate in the northeastern United States, resulting in the formation of acid precipitation and visibility-reducing sulfate aerosol (Penkett et al., 1979; Lind et al., 1987; Madronich and Calvert, 1990; Tanner and Schorran, 1995). Atmospheric hydrogen peroxide (H{sub 2}O{sub 2} or HP) is produced by the self-reaction of hydroperoxyl radicals (HO{sub 2}); higher organic peroxides are produced by reaction of HO{sub 2} with alkylperoxyl radicals (RO{sub 2}). Peroxyl radicals, along with OH, are chain carriers in the complex photochemical process that produces tropospheric ozone. Thus, concentrations of peroxides and their free radical precursors depend on solar intensity and ambient concentrations of water vapor, ozone, NO{sub x} (NO + NO{sub 2}), and VOCs (volatile organic compounds). Several investigators have demonstrated that HP and hydroxymethyl hydroperoxide (HOCH2 OOH or HMHP) also may be formed when ozone reacts with alkenes in moist air (Becker et al., 1990; Hewitt and Kok, 1991; Gaeb et al., 1995). Peroxides are the expected sink for peroxyl radicals when concentrations of NO are low. Otherwise, these radicals react with NO to form NO{sub 2}. Under high NO{sub x} conditions, NO{sub z} (oxidation products of NO and NO{sub 2}) becomes the principal radical sink. Therefore, formation rates of peroxides relative to NO{sub z} provide information about the history of an air mass and the expected sensitivity of ozone production to reduced emissions (Kleinman et al., 1997; Sillman, 1995; 1997). Through photolysis and reaction with OH, peroxides also act as a radical source; thus, reliable peroxide measurements are necessary for calculating ozone production rates. In this paper, we will summarize peroxide observations at the Williams Tower, and aboard the U.S. Department of Energy G-1 research aircraft in Houston, TX, during August and

  13. Method and Apparatus for Measuring Surface Air Pressure

    NASA Technical Reports Server (NTRS)

    Lin, Bing (Inventor); Hu, Yongxiang (Inventor)

    2014-01-01

    The present invention is directed to an apparatus and method for remotely measuring surface air pressure. In one embodiment, the method of the present invention utilizes the steps of transmitting a signal having multiple frequencies into the atmosphere, measuring the transmitted/reflected signal to determine the relative received power level of each frequency and then determining the surface air pressure based upon the attenuation of the transmitted frequencies.

  14. Verification of CORINAIR 90 emission inventory by comparison with ambient air measurements

    SciTech Connect

    Pulles, T.; Esser, P.; Mareckova, K.; Kozakovic, L.

    1996-12-31

    This study aims at a validation of the CORINAIR 90 emission inventory by a comparison with measured air quality in the Netherlands and in the Slovak Republic. A regional scale atmospheric transport model (Lows) has been used to calculate air quality on a {+-} 60 {times} 60 km{sup 2} grid over Europe, using the CORINAIR 90 emissions database. The calculations have been performed for the 1990 meteorological situation. Application of the model results in calculated yearly averaged wind direction dependent concentrations of NO{sub x}, SO{sub 2} and CO. These results are statistically compared with measurements of national air quality monitoring networks in both countries. Due to characteristics of the monitoring networks in the Netherlands and in the Slovak Republic, the results of this comparison are more conclusive for the Netherlands as compared to the Slovak Republic. Slovak measuring sites seem to be influenced by local effects to such an extent that comparison with the relatively course spatial resolution of the model does not yield clear results. Within the Netherlands a fair agreement between calculated and measured air pollutant concentrations is observed for SO{sub 2} no clear pattern is recognized in the comparison. Differences between measurements and calculations are mainly attributed to local influences. NO{sub x} and CO concentrations appear to be underestimated at south-easterly wind directions. At many grid cells calculated concentrations are lower than the measured ones. The difference seems to be larger for NO{sub x} than for CO.

  15. 10 CFR 835.209 - Concentrations of radioactive material in air.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... concentration (DAC) values given in appendices A and C of this part shall be used in the control of occupational... 10 Energy 4 2012-01-01 2012-01-01 false Concentrations of radioactive material in air. 835.209 Section 835.209 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal...

  16. 10 CFR 835.209 - Concentrations of radioactive material in air.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... concentration (DAC) values given in appendices A and C of this part shall be used in the control of occupational... 10 Energy 4 2011-01-01 2011-01-01 false Concentrations of radioactive material in air. 835.209 Section 835.209 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal...

  17. 10 CFR 835.209 - Concentrations of radioactive material in air.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... concentration (DAC) values given in appendices A and C of this part shall be used in the control of occupational... 10 Energy 4 2013-01-01 2013-01-01 false Concentrations of radioactive material in air. 835.209 Section 835.209 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal...

  18. 10 CFR 835.209 - Concentrations of radioactive material in air.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... concentration (DAC) values given in appendices A and C of this part shall be used in the control of occupational... 10 Energy 4 2014-01-01 2014-01-01 false Concentrations of radioactive material in air. 835.209 Section 835.209 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal...

  19. Evaluation of optical source-detector configurations for tomographic reconstruction of chemical concentrations in indoor air.

    PubMed

    Todd, L; Ramachandran, G

    1994-12-01

    This article reports on numerical studies to evaluate and compare optical remote sensing configurations for tomographically reconstructing pollutant concentrations in indoor air. With a remote sensing/computed tomography system, two-dimensional maps of pollutant concentrations with good spatial resolution can be created for an entire room. The successful use of such a system for exposure assessment, ventilation assessment, or source monitoring depends on the remote sensing configuration. A systematic method was developed to evaluate the performance of 10 configurations. One hundred and twenty test maps were reconstructed with an algebraic reconstruction method using all 10 configurations; reconstruction quality was evaluated using 4 criteria. Reconstruction quality was related to the number and location of detectors in the room and the complexity of the test maps. Configurations using the same number of detectors placed in different locations resulted in reconstructions that differed in quality. The effect of reducing the number density of rays on reconstruction quality was studied. Based on these simulations, two configurations that used four detectors to scan the room were selected, and their performance was evaluated in the presence of various levels of measurement noise. Two configurations that used four detectors were most suited for exposure assessment. It was found that when designing a configuration, the number and independence of rays should be maximized. Results underscored the need to thoroughly test configurations through numerical studies prior to field implementation; a wide variety of concentration maps, relevant to the application, should be tested under both ideal and nonideal sampling conditions. PMID:7825513

  20. Influences of ambient air PM₂.₅ concentration and meteorological condition on the indoor PM₂.₅ concentrations in a residential apartment in Beijing using a new approach.

    PubMed

    Han, Yang; Qi, Meng; Chen, Yilin; Shen, Huizhong; Liu, Jing; Huang, Ye; Chen, Han; Liu, Wenxin; Wang, Xilong; Liu, Junfeng; Xing, Baoshan; Tao, Shu

    2015-10-01

    PM2.5 concentrations in a typical residential apartment in Beijing and immediately outside of the building were measured simultaneously during heating and non-heating periods. The objective was to quantitatively explore the relationship between indoor and outdoor PM2.5 concentrations. A statistical method for predicting indoor PM2.5 concentrations was proposed. Ambient PM2.5 concentrations were strongly affected by meteorological conditions, especially wind directions. A bimodal distribution was identified during the heating season due to the frequent and rapid transition between severe pollution events and clean days. Indoor PM2.5 concentrations were significantly correlated with outdoor PM2.5 concentrations but with 1-2 h delay, and the differences can be explained by ambient meteorological features, such as temperature, humidity, and wind direction. These results indicate the potential to incorporate indoor exposure features to the regional air quality model framework and to more accurately estimate the epidemiological relationship between human mortality and air pollution exposure.

  1. Soil air CO2 concentration as an integrative parameter of soil structure

    NASA Astrophysics Data System (ADS)

    Ebeling, Corinna; Gaertig, Thorsten; Fründ, Heinz-Christian

    2015-04-01

    The assessment of soil structure is an important but difficult issue and normally takes place in the laboratory. Typical parameters are soil bulk density, porosity, water or air conductivity or gas diffusivity. All methods are time-consuming. The integrative parameter soil air CO2 concentration ([CO2]) can be used to assess soil structure in situ and in a short time. Several studies highlighted that independent of soil respiration, [CO2] in the soil air increases with decreasing soil aeration. Therefore, [CO2] is a useful indicator of soil aeration. Embedded in the German research project RÜWOLA, which focus on soil protection at forest sites, we investigated soil compaction and recovery of soil structure after harvesting. Therefore, we measured soil air CO2 concentrations continuously and in single measurements and compared the results with the measurements of bulk density, porosity and gas diffusivity. Two test areas were investigated: At test area 1 with high natural regeneration potential (clay content approx. 25 % and soil-pH between 5 and 7), solid-state CO2-sensors using NDIR technology were installed in the wheel track of different aged skidding tracks in 5 and 10 cm soil depths. At area 2 (acidic silty loam, soil-pH between 3.5 and 4), CO2-sensors and water-tension sensors (WatermarkR) were installed in 6 cm soil depth. The results show a low variance of [CO2] in the undisturbed soil with a long term mean from May to June 2014 between 0.2 and 0.5 % [CO2] in both areas. In the wheel tracks [CO2] was consistently higher. The long term mean [CO2] in the 8-year-old-wheel track in test area 1 is 5 times higher than in the reference soil and shows a high variation (mean=2.0 %). The 18-year-old wheel track shows a long-term mean of 1.2 % [CO2]. Furthermore, there were strong fluctuations of [CO2] in the wheel tracks corresponding to precipitation and humidity. Similar results were yielded with single measurements during the vegetation period using a portable

  2. Measuring In-Air and Underwater Hearing in Seabirds.

    PubMed

    Crowell, Sara C

    2016-01-01

    Electrophysiological methods were used to measure the in-air hearing of 10 species of seabirds. There are currently no measures of the underwater hearing abilities of diving birds. In preparation for constructing a behavioral audiogram both in-air and underwater hearing, several species of diving ducks were raised. Because there is a considerable amount of literature on bird hearing in air, the technical setup and training methods were modeled on similar studies, with modifications to address the nature of the underwater sound field and the difficulty of the task for the birds. PMID:26611081

  3. Measuring In-Air and Underwater Hearing in Seabirds.

    PubMed

    Crowell, Sara C

    2016-01-01

    Electrophysiological methods were used to measure the in-air hearing of 10 species of seabirds. There are currently no measures of the underwater hearing abilities of diving birds. In preparation for constructing a behavioral audiogram both in-air and underwater hearing, several species of diving ducks were raised. Because there is a considerable amount of literature on bird hearing in air, the technical setup and training methods were modeled on similar studies, with modifications to address the nature of the underwater sound field and the difficulty of the task for the birds.

  4. Comparison of Ambient Radon Concentrations in Air in the Northern Mojave Desert from Continuous and Integrating Instruments

    SciTech Connect

    David S. Shafer; David McGraw; Lynn H. Karr; Greg McCurdy; Tammy L. Kluesner; Karen J. Gray; Jeffrey Tappen

    2010-05-18

    As part of a program to characterize and baseline environmental parameters, ambient radon-222 (Rn) monitoring was conducted in the rural community of Amargosa Valley, NV, the closest community to Yucca Mountain. Passive integrating and continuous Rn monitoring instruments were deployed adjacent to the Community Environmental Monitoring Program (CEMP) station in Amargosa Valley. The CEMP station provided real-time ambient gamma exposure and meteorological data used to correct the integrated Rn measurements, verified the meteorological data collected by the continuous Rn monitoring instrument, and for provided instrumentation for evaluating the relationships between meteorological conditions and Rn concentrations. Hourly Rn concentrations in air measured by the continuous Rn monitoring instrument (AlphaGUARD®) were compared to the average hourly values for the integrating Rn measurements (E-PERM®) by dividing the total Rn measurements by the number of hours the instruments were deployed. The results of the comparison indicated that average hourly ambient Rn concentrations as measured by both methods ranged from 0.2 to 0.4 pico-curies per liter of air. Ambient Rn values for the AlphaGUARD exhibited diurnal variations. When Rn concentrations were compared with measurements of temperature (T), barometric pressure, and relative humidity, the correlation (inversely) was highest with T, albeit weakly.

  5. 40 CFR 92.108 - Intake and cooling air measurements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... device for all modes except idle. For idle, the measurement accuracy shall be ±5 percent or less of the...) Corrections to the measured air mass flowrate shall be made when an engine system incorporates devices that... from these devices shall be approved by the Administrator. (3) Measurements made in accordance with...

  6. The concentration-response relation between air pollution and daily deaths.

    PubMed Central

    Schwartz, J; Ballester, F; Saez, M; Pérez-Hoyos, S; Bellido, J; Cambra, K; Arribas, F; Cañada, A; Pérez-Boillos, M J; Sunyer, J

    2001-01-01

    Studies on three continents have reported associations between various measures of airborne particles and daily deaths. Sulfur dioxide has also been associated with daily deaths, particularly in Europe. Questions remain about the shape of those associations, particularly whether there are thresholds at low levels. We examined the association of daily concentrations of black smoke and SO(2) with daily deaths in eight Spanish cities (Barcelona, Bilbao, Castellón, Gijón, Oviedo, Valencia, Vitoria, and Zaragoza) with different climates and different environmental and social characteristics. We used nonparametric smoothing to estimate the shape of the concentration-response curve in each city and combined those results using a metasmoothing technique developed by Schwartz and Zanobetti. We extended their method to incorporate random variance components. Black smoke had a nearly linear association with daily deaths, with no evidence of a threshold. A 10 microg/m(3) increase in black smoke was associated with a 0.88% increase in daily deaths (95% confidence interval, 0.56%-1.20%). SO(2) had a less plausible association: Daily deaths increased at very low concentrations, but leveled off and then decreased at higher concentrations. These findings held in both one- and two-pollutant models and held whether we optimized our weather and seasonal model in each city or used the same smoothing parameters in each city. We conclude that the association with particle levels is more convincing than for SO(2), and without a threshold. Linear models provide an adequate estimation of the effect of particulate air pollution on mortality at low to moderate concentrations. PMID:11675264

  7. Relationships between ozone photolysis rates and peroxy radical concentrations in clean marine air over the Southern Ocean

    NASA Astrophysics Data System (ADS)

    Penkett, S. A.; Monks, P. S.; Carpenter, L. J.; Clemitshaw, K. C.; Ayers, G. P.; Gillett, R. W.; Galbally, I. E.; Meyer, C. P.

    1997-06-01

    Measurements of the sum of inorganic and organic peroxy radicals (RO2) and photolysis rate coefficients J(NO2) and J(O1D) have been made at Cape Grim, Tasmania in the course of a comprehensive experiment which studied photochemistry in the unpolluted marine boundary layer. The SOAPEX (Southern Ocean Atmospheric Photochemistry Experiment) campaign included measurements of ozone, peroxides, nitrogen oxides, water vapor, and many other parameters. This first full length paper concerned with the experiment focuses on the types of relationships observed between peroxy radicals and J(NO2), J(O1D) and √[J(O1D)] in different air masses in which ozone is either produced or destroyed by photochemistry. It was found that in baseline air with ozone loss, RO2 was proportional to √[J(O1D)], whereas in more polluted air RO2 was proportional to J(O1D). Simple algorithms were derived to explain these relationships and also to calculate the concentrations of OH radicals in baseline air from the instantaneous RO2 concentrations. The signal to noise ratio of the peroxy radical measurements was up to 10 for 1-min values and much higher than in other previous deployments of the instrument in the northern hemisphere, leading to the confident determination of the relationships between RO2 and J(O1D) in different conditions. The absolute concentration Of RO2 determined in these experiments is in some doubt, but this does not affect our conclusions concerned either with the behavior of peroxy radicals with changing light levels or with the concentrations of OH calculated from RO2. The results provide confidence that the level of understanding of the photochemistry of ozone leading to the production of peroxide via recombination of peroxy radicals in clean air environments is well advanced.

  8. Rural southeast Texas air quality measurements during the 2006 Texas Air Quality Study.

    PubMed

    Schade, Gunnar W; Khan, Siraj; Park, Changhyoun; Boedeker, Ian

    2011-10-01

    The authors conducted air quality measurements of the criteria pollutants carbon monoxide, nitrogen oxides, and ozone together with meteorological measurements at a park site southeast of College Station, TX, during the 2006 Texas Air Quality Study II (TexAQS). Ozone, a primary focus of the measurements, was above 80 ppb during 3 days and above 75 ppb during additional 8 days in summer 2006, suggestive of possible violations of the ozone National Ambient Air Quality Standard (NAAQS) in this area. In concordance with other air quality measurements during the TexAQS II, elevated ozone mixing ratios coincided with northerly flows during days after cold front passages. Ozone background during these days was as high as 80 ppb, whereas southerly air flows generally provided for an ozone background lower than 40 ppb. Back trajectory analysis shows that local ozone mixing ratios can also be strongly affected by the Houston urban pollution plume, leading to late afternoon ozone increases of as high as 50 ppb above background under favorable transport conditions. The trajectory analysis also shows that ozone background increases steadily the longer a southern air mass resides over Texas after entering from the Gulf of Mexico. In light of these and other TexAQS findings, it appears that ozone air quality is affected throughout east Texas by both long-range and regional ozone transport, and that improvements therefore will require at least a regionally oriented instead of the current locally oriented ozone precursor reduction policies.

  9. Optical Air Flow Measurements for Flight Tests and Flight Testing Optical Air Flow Meters

    NASA Technical Reports Server (NTRS)

    Jentink, Henk W.; Bogue, Rodney K.

    2005-01-01

    Optical air flow measurements can support the testing of aircraft and can be instrumental to in-flight investigations of the atmosphere or atmospheric phenomena. Furthermore, optical air flow meters potentially contribute as avionics systems to flight safety and as air data systems. The qualification of these instruments for the flight environment is where we encounter the systems in flight testing. An overview is presented of different optical air flow measurement techniques applied in flight and what can be achieved with the techniques for flight test purposes is reviewed. All in-flight optical airflow velocity measurements use light scattering. Light is scattered on both air molecules and aerosols entrained in the air. Basic principles of making optical measurements in flight, some basic optical concepts, electronic concepts, optoelectronic interfaces, and some atmospheric processes associated with natural aerosols are reviewed. Safety aspects in applying the technique are shortly addressed. The different applications of the technique are listed and some typical examples are presented. Recently NASA acquired new data on mountain rotors, mountain induced turbulence, with the ACLAIM system. Rotor position was identified using the lidar system and the potentially hazardous air flow profile was monitored by the ACLAIM system.

  10. Utilization of lasers for air data measurements

    NASA Astrophysics Data System (ADS)

    Hammer, J.

    1991-05-01

    The operating principles of the ALEV3 three axis laser Doppler anemometer, which was designed for flight tests with the A-320 and A-340 aircraft, are depicted. If mounted on the aircraft center of gravity, the ALEV-3 allows true flight velocity in three directions and angles of attack and sideslip to be directly measured with a very good accuracy, in particular flight areas such as limit buffeting, stall, high Mach numbers, or sideslip flights. Aircraft parameter estimation, calculation, and calibration results are presented. The accuracies of velocity, static pressure and aerodynamic angle measurements were compared with classical anemometers precisions. Flight tests results of the ALEV-1 one axis laser anemometer for A-320 are given as a reference.

  11. Effects of trans-Eurasian transport of air pollutants on surface ozone concentrations over Western China

    NASA Astrophysics Data System (ADS)

    Li, Xiaoyuan; Liu, Junfeng; Mauzerall, Denise L.; Emmons, Louisa K.; Walters, Stacy; Horowitz, Larry W.; Tao, Shu

    2014-11-01

    Due to a lack of industrialization in Western China, surface air there was, until recently, believed to be relatively unpolluted. However, recent measurements and modeling studies have found high levels of ozone (O3) there. Based on the state-of-the-science global chemical transport model MOZART-4, we identify the origin, pathway, and mechanism of trans-Eurasian transport of air pollutants to Western China in 2000. MOZART-4 generally simulates well the observed surface O3 over inland areas of China. Simulations find surface ozone concentrations over Western China on average to be about 10 ppbv higher than Eastern China. Using sensitivity studies, we find that anthropogenic emissions from all Eurasian regions except China contribute 10-15 ppbv surface O3 over Western China, superimposed upon a 35-40 ppbv natural background. Transport from European anthropogenic sources to Northwestern China results in 2-6 ppbv O3 enhancements in spring and summer. Indian anthropogenic sources strongly influence O3 over the Tibetan Plateau during the summer monsoon. Transport of O3 originating from emissions in the Middle East occasionally reach Western China and increase surface ozone there by about 1-4 ppbv. These influences are of similar magnitude as trans-Pacific and transatlantic transport of O3 and its precursors, indicating the significance of trans-Eurasian ozone transport in hemispheric transport of air pollution. Our study further indicates that mitigation of anthropogenic emissions from Europe, the Indian subcontinent, and the Middle East could benefit public health and agricultural productivity in Western China.

  12. Radon ((222)Rn) concentration in indoor air near the coal mining area of Nui Beo, North of Vietnam.

    PubMed

    Nhan, Dang Duc; Fernando, Carvalho P; Thu Ha, Nguyen Thi; Long, Nguyen Quang; Thuan, Dao Dinh; Fonseca, Heloisa

    2012-08-01

    Concentrations of radioactive radon gas ((222)Rn) were measured using passive monitors based on LR115 solid state track detectors during June-July 2010 in indoor air of dwellings in the Nui Beo coal mining area, mostly in Cam Pha and Ha Long coastal towns, Quang Ninh province, in the North of Vietnam. Global results of (222)Rn concentrations indoors varied from ≤6 to 145 Bq m(-3) averaging 46 ± 26 Bq m(-3) (n = 37), with a median value of 47 Bq m(-3). This was similar to outdoor (222)Rn concentrations in the region, averaging 43 ± 19 Bq m(-3) (n = 10), with a median value of 44 Bq m(-3). Indoor (222)Rn concentrations in the coastal town dwellings only were in average lower although not significantly different from indoor (222)Rn concentrations measured at the coal storage field near the harbor, 67 ± 4 Bq m(-3) (n = 3). Furthermore, there was no significant difference in the average (222)Rn concentration in indoor air measured in the coastal towns region and those at the touristic Tuan Chau Island located about 45 km south of the coal mine, in the Ha Long Bay. The indoor (222)Rn concentration in a floating house at the Bai Tu Long Bay, and assumed as the best estimate of the baseline (222)Rn in surface air, was 27 ± 3 Bq m(-3) (n = 3). Indoor average concentration of (222)Rn in dwellings at the Ha Noi city, inland and outside the coal mining area, was determined at 30 Bq m(-3). These results suggest that (222)Rn exhalation from the ground at the Nui Beo coal mining area may have contributed to generally increase (222)Rn concentration in the surface air of that region up to 1.7 times above the baseline value measured at the Bai Tu Long Bay and Ha Noi. The average indoor concentration of (222)Rn in Cam Pha-Ha Long area is about one-third of the value of the so-called Action Level set up by the US EPA of 148 Bq m(-3). Results suggest that there is no significant public health risk from (222)Rn exposure in the study region.

  13. Using broadband absorption spectroscopy to measure concentration of sulfur dioxide

    NASA Astrophysics Data System (ADS)

    Wang, H. S.; Zhang, Y. G.; Wu, S. H.; Lou, X. T.; Zhang, Z. G.; Qin, Y. K.

    2010-09-01

    A linear relationship between concentration of sulfur dioxide (SO2) and optical parameter (OP) is established using the Beer-Lambert law. The SO2 measuring system is set up to measure the concentration of sulfur dioxide in the wavelength range 275-315 nm. Experimental results indicate that the detection limit of the sulfur dioxide measuring system is below 0.2 ppm per meter of path length, and the measurement precision is better than ±1%. The proposed SO2 measuring method features limited interference from other gases and dust, and high stability and short response time.

  14. Device and method for accurately measuring concentrations of airborne transuranic isotopes

    DOEpatents

    McIsaac, C.V.; Killian, E.W.; Grafwallner, E.G.; Kynaston, R.L.; Johnson, L.O.; Randolph, P.D.

    1996-09-03

    An alpha continuous air monitor (CAM) with two silicon alpha detectors and three sample collection filters is described. This alpha CAM design provides continuous sampling and also measures the cumulative transuranic (TRU), i.e., plutonium and americium, activity on the filter, and thus provides a more accurate measurement of airborne TRU concentrations than can be accomplished using a single fixed sample collection filter and a single silicon alpha detector. 7 figs.

  15. Device and method for accurately measuring concentrations of airborne transuranic isotopes

    DOEpatents

    McIsaac, Charles V.; Killian, E. Wayne; Grafwallner, Ervin G.; Kynaston, Ronnie L.; Johnson, Larry O.; Randolph, Peter D.

    1996-01-01

    An alpha continuous air monitor (CAM) with two silicon alpha detectors and three sample collection filters is described. This alpha CAM design provides continuous sampling and also measures the cumulative transuranic (TRU), i.e., plutonium and americium, activity on the filter, and thus provides a more accurate measurement of airborne TRU concentrations than can be accomplished using a single fixed sample collection filter and a single silicon alpha detector.

  16. Twenty years of measurement of polycyclic aromatic hydrocarbons (PAHs) in UK ambient air by nationwide air quality networks.

    PubMed

    Brown, Andrew S; Brown, Richard J C; Coleman, Peter J; Conolly, Christopher; Sweetman, Andrew J; Jones, Kevin C; Butterfield, David M; Sarantaridis, Dimitris; Donovan, Brian J; Roberts, Ian

    2013-06-01

    The impact of human activities on the health of the population and of the wider environment has prompted action to monitor the presence of toxic compounds in the atmosphere. Toxic organic micropollutants (TOMPs) are some of the most insidious and persistent of these pollutants. Since 1991 the United Kingdom has operated nationwide air quality networks to assess the presence of TOMPs, including polycyclic aromatic hydrocarbons (PAHs), in ambient air. The data produced in 2010 marked 20 years of nationwide PAH monitoring. This paper marks this milestone by providing a novel and critical review of the data produced since nationwide monitoring began up to the end of 2011 (the latest year for which published data is available), discussing how the networks performing this monitoring has evolved, and elucidating trends in the concentrations of the PAHs measured. The current challenges in the area and a forward look to the future of air quality monitoring for PAHs are also discussed briefly. PMID:23636622

  17. Measurement of air quality within storage domes in technical area 54, areas G and L

    SciTech Connect

    Anderson, E.

    1994-03-15

    The concentrations of volatile organic compounds (VOCs) and tritium inside of storage domes at TA-54 were measured to assess worker exposure and support the Area G site characterization, including the Radioactive Air Emissions Management (RAEM) program. Samples were collected at 2-3 locations within Domes 48, 49, and 153 on up to six days during the summer of 1994. Samples were collected to evaluate three scenarios: (1) normal working activities with the domes open; (2) after domes were closed overnight; and (3) after domes were closed for three days. Eight-hour integrated samples were collected and analyzed in Radian`s Austin laboratories. Tritium activities from 17.1 to 69,900 pCi/m{sup 3} were measured. About two dozen individual VOCs were identified in each sample, but most of the concentration levels were very low (e.g.; < 1 to 10 ppbv). The highest concentrations measured were bromomethane (56.5 ppbv), 1, 1,1-trichloroethane (75.4 ppbv), propane (958 ppbv), methylene chloride (1,450 ppbv), and toluene (22.8). The measured VOC concentrations were well below the action levels developed by the New Mexico Environment Department and the measured tritium concentrations were well below the DOE`s derived air concentration (DAC). The variability in concentration within a dome during a single sampling episode was small. The concentrations were about an order of magnitude (i.e., 10x) higher after the domes had been closed overnight compared with the domes when open. Closing the domes over the weekend did not result in significantly higher concentrations (e.g.; > 20%) than when the domes were closed only overnight. The data were used to generate estimated annual dome emission rates of 0.3 Ci/yr of tritium and less than 100 lbs/yr of VOCs. The measured VOC concentrations were collected during the warmest months of the year and therefore should represent worst-case air impacts.

  18. Air-vegetation exchange of SOCs as a control of atmospheric concentrations and residence times

    SciTech Connect

    Hornbuckle, K.C.; Eisenreich, S.J.

    1994-12-31

    Semi-volatile organic compounds (SOCs) such as the polychlorinated biphenyls exhibit seasonal maxima in atmospheric concentrations with highest values in the warm summer. This generally believed to result from the effect of temperature on SOC vapor pressure with direct and important implications to global transport. The authors have conducted a series of field experiments whereby air samples were collected above an ombrotrophic, forested bog in northern MN at a frequency of 6 day{sup {minus}1} during the fall, winter, spring and summer. Samples of Sphagnum moss and other vegetation were also collected on each occasion. All samples were analyzed for PCBs, low MW PAHs, gaseous hydrocarbons and selected pesticides. Meteorological and soils data were collected during all experiments (air and soil temperature, wind direction and velocity, RH). Diurnal concentration data, air-plant and air-soil partition coefficients and probable mechanisms and kinetics of SOC-plant interactions will be presented.

  19. Passive sampler for measurements of atmospheric nitric acid vapor (HNO3) concentrations.

    PubMed

    Bytnerowicz, A; Padgett, P E; Arbaugh, M J; Parker, D R; Jones, D P

    2001-12-01

    Nitric acid (HNO3) vapor is an important nitrogenous air pollutant responsible for increasing saturation of forests with nitrogen and direct injury to plants. The USDA Forest Service and University of California researchers have developed a simple and inexpensive passive sampler for monitoring air concentrations of HNO3. Nitric acid is selectively absorbed on 47-mm Nylasorb nylon filters with no interference from particulate NO3-. Concentrations determined with the passive samplers closely corresponded with those measured with the co-located honeycomb annular denuder systems. The PVC protective caps of standardized dimensions protect nylon filters from rain and wind and allow for reliable measurements of ambient HNO3 concentrations. The described samplers have been successfully used in Sequoia National Park, the San Bernardino Mountains, and on Mammoth Mountain in California.

  20. Roadside air quality and implications for control measures: A case study of Hong Kong

    NASA Astrophysics Data System (ADS)

    Ai, Z. T.; Mak, C. M.; Lee, H. C.

    2016-07-01

    Traffic related air pollution is one of major environmental issues in densely populated urban areas including Hong Kong. A series of control measures has been implemented by Hong Kong government to cut traffic related air pollutants, including retrofitting the Euro II and Euro III buses with selective catalytic reduction (SCR) devices to lower nitrogen dioxide (NO2) emissions. In order to reveal the real-life roadside air quality and evaluate the effectiveness of the control measures, this study first analyzed the recent six-year data regarding concentrations of pollutants typically associated with traffic recorded in two governmental roadside monitoring stations and second conducted on-site measurements of concentration of pollutants at pedestrian level near five selected roads. Given that there is a possibility of ammonia leakage as a secondary pollutant from SCR devices, a special attention was paid to the measurements of ammonia level in bus stations and along roadsides. Important influencing factors, such as traffic intensity, street configuration and season, were analyzed. Control measures implemented by the government are effective to decrease the traffic emissions. In 2014, only NO2 cannot achieve the annual air quality objective of Hong Kong. However, it is important to find that particulate matters, rather than NO2, post potentially a short-term exposure risk to passengers and pedestrians. Based on the findings of this study, specific control measures are suggested, which are intended to further improve the roadside air quality.

  1. Formaldehyde emission behavior of building materials: on-site measurements and modeling approach to predict indoor air pollution.

    PubMed

    Bourdin, Delphine; Mocho, Pierre; Desauziers, Valérie; Plaisance, Hervé

    2014-09-15

    The purpose of this paper was to investigate formaldehyde emission behavior of building materials from on-site measurements of air phase concentration at material surface used as input data of a box model to estimate the indoor air pollution of a newly built classroom. The relevance of this approach was explored using CFD modeling. In this box model, the contribution of building materials to indoor air pollution was estimated with two parameters: the convective mass transfer coefficient in the material/air boundary layer and the on-site measurements of gas phase concentration at material surfaces. An experimental method based on an emission test chamber was developed to quantify this convective mass transfer coefficient. The on-site measurement of gas phase concentration at material surface was measured by coupling a home-made sampler to SPME. First results had shown an accurate estimation of indoor formaldehyde concentration in this classroom by using a simple box model.

  2. Measurement and Characterization of Concentrator Solar Cells II

    NASA Technical Reports Server (NTRS)

    Scheiman, Dave; Sater, Bernard L.; Chubb, Donald; Jenkins, Phillip; Snyder, Dave

    2005-01-01

    Concentrator solar cells are continuing to get more consideration for use in power systems. This interest is because concentrator systems can have a net lower cost per watt in solar cell materials plus ongoing improvements in sun-tracking technology. Quantitatively measuring the efficiency of solar cells under concentration is difficult. Traditionally, the light concentration on solar cells has been determined by using a ratio of the measured solar cell s short circuit current to that at one sun, this assumes that current changes proportionally with light intensity. This works well with low to moderate (<20 suns) concentration levels on "well-behaved" linear cells but does not apply when cells respond superlinearly, current increases faster than intensity, or sublinearly, current increases more slowly than intensity. This paper continues work on using view factors to determine the concentration level and linearity of the solar cell with mathematical view factor analysis and experimental results [1].

  3. Estimation of background gas concentration from differential absorption lidar measurements

    NASA Astrophysics Data System (ADS)

    Harris, Peter; Smith, Nadia; Livina, Valerie; Gardiner, Tom; Robinson, Rod; Innocenti, Fabrizio

    2016-10-01

    Approaches are considered to estimate the background concentration level of a target species in the atmosphere from an analysis of the measured data provided by the National Physical Laboratory's differential absorption lidar (DIAL) system. The estimation of the background concentration level is necessary for an accurate quantification of the concentration level of the target species within a plume, which is the quantity of interest. The focus of the paper is on methodologies for estimating the background concentration level and, in particular, contrasting the assumptions about the functional and statistical models that underpin those methodologies. An approach is described to characterise the noise in the recorded signals, which is necessary for a reliable estimate of the background concentration level. Results for measured data provided by a field measurement are presented, and ideas for future work are discussed.

  4. Intercomparison of number concentration measurements by various aerosol particle counters

    NASA Astrophysics Data System (ADS)

    Ankilov, A.; Baklanov, A.; Colhoun, M.; Enderle, K.-H.; Gras, J.; Julanov, Yu.; Kaller, D.; Lindner, A.; Lushnikov, A. A.; Mavliev, R.; McGovern, F.; Mirme, A.; O'Connor, T. C.; Podzimek, J.; Preining, O.; Reischl, G. P.; Rudolf, R.; Sem, G. J.; Szymanski, W. W.; Tamm, E.; Vrtala, A. E.; Wagner, P. E.; Winklmayr, W.; Zagaynov, V.

    Total aerosol particle number concentrations, as measured by means of 16 different measurement systems, have been quantitatively compared during an international workshop at the Institute for Experimental Physics of the University of Vienna, Austria, which was coordinated within the Committee on Nucleation and Atmospheric Aerosols (ICCP-IUGG). The range of measuring instruments includes Pollak counters (PCO) in use already for several decades, presently available commercial particle counters, as well as laboratory prototypes. The operation of the instruments considered was based on different measurement principles: (1) adiabatic expansion condensation particle counter, (2) flow diffusion condensation particle counter, (3) turbulent mixing condensation particle counter, (4) laser optical particle counter, and (5) electrostatic particle measurement system. Well-defined test aerosols with various chemical compositions were considered: DEHS, sodium chloride, silver, hydrocarbons, and tungsten oxide. The test aerosols were nearly monodispersed with mean particle diameters between 4 and 520 nm, the particle number concentrations were varied over a range from about 4×10 1 to 7×10 6 cm -3. A few measurements were performed with two-component aerosol mixtures. For simultaneous concentration measurements, the various instruments considered were operated under steady state conditions in a linear flow system. A series of at least 10 single concentration measurements was performed by each individual instrument at each set of test aerosol parameters. The average of the concentration data measured by the various instruments was defined as a common reference. The number concentrations obtained from the various instruments typically agreed within a factor of about two over the entire concentration range considered. The agreement of the measured concentrations is notable considering the various different measurement principles applied in this study, and particularly in view of the

  5. Air radioactivity levels following the Fukushima reactor accident measured at the Laboratoire Souterrain de Modane, France.

    PubMed

    Loaiza, P; Brudanin, V; Piquemal, F; Reyss, J-L; Stekl, I; Warot, G; Zampaolo, M

    2012-12-01

    The radioactivity levels in the air of the radionuclides released by the Fukushima accident were measured at the Laboratoire Souterrain de Modane, in the South-East of France, during the period 25 March-18 April 2011. Air-filters from the ventilation system exposed for one or two days were measured using low-background gamma-ray spectrometry. In this paper we present the activity concentrations obtained for the radionuclides (131)I, (132)Te, (134)Cs, (137)Cs, (95)Nb, (95)Zr, (106)Ru, (140)Ba/La and (103)Ru. The activity concentration of (131)I was of the order of 100 μBq/m(3), more than 100 times higher than the activities of other fission products. The highest activities of (131)I were measured as a first peak on 30 March and a second peak on 3-4 April. The activity concentrations of (134)Cs and (137)Cs varied from 5 to 30 μBq/m(3). The highest activity concentration recorded for Cs corresponded to the same period as for (131)I, with a peak on 2-3 April. The results of the radioactivity concentration levels in grass and mushrooms exposed to the air in the Modane region were also measured. Activity concentrations of (131)I of about 100 mBq/m(2) were found in grass.

  6. Measurement results obtained from air quality monitoring system

    SciTech Connect

    Turzanski, P.K.; Beres, R.

    1995-12-31

    An automatic system of air pollution monitoring operates in Cracow since 1991. The organization, assembling and start-up of the network is a result of joint efforts of the US Environmental Protection Agency and the Cracow environmental protection service. At present the automatic monitoring network is operated by the Provincial Inspection of Environmental Protection. There are in total seven stationary stations situated in Cracow to measure air pollution. These stations are supported continuously by one semi-mobile (transportable) station. It allows to modify periodically the area under investigation and therefore the 3-dimensional picture of creation and distribution of air pollutants within Cracow area could be more intelligible.

  7. Atmospheric radionuclide concentrations measured by Pacific Northwest Laboratory since 1961

    SciTech Connect

    Young, J.A.; Thomas, C.W.

    1981-03-01

    The atmospheric concentrations of a wide spectrum of radionuclides produced by nuclear weapons, nuclear reactors, cosmic rays, radon and thoron decay and the SNAP-9A burn-up ([sup 238]Pu) have been measured at Richland, Washington, since 1961; at Barrow, Alaska, since 1964; and at other stations for shorter periods of time. There has been considerable concern over the health hazard presented by these radionuclides, but it has also been recognized that atmospheric mixing and deposition rates can be determined from their measurement. Therefore, Pacific Northwest Laboratory began the continuous measurement of the atmospheric concentrations of a wide spectrum of radionuclides produced by nuclear weapons, nuclear reactors, cosmic rays, and radon and thoron decay. This report will discuss the concentrations of the longer-lived radionuclides (T 1/2 > 12 days). The concentrations of shorter-lived radionuclides measured following Chinese nuclear tests since 1972 are discussed in another report.

  8. Atmospheric radionuclide concentrations measured by Pacific Northwest Laboratory since 1961

    SciTech Connect

    Young, J.A.; Thomas, C.W.

    1981-03-01

    The atmospheric concentrations of a wide spectrum of radionuclides produced by nuclear weapons, nuclear reactors, cosmic rays, radon and thoron decay and the SNAP-9A burn-up ({sup 238}Pu) have been measured at Richland, Washington, since 1961; at Barrow, Alaska, since 1964; and at other stations for shorter periods of time. There has been considerable concern over the health hazard presented by these radionuclides, but it has also been recognized that atmospheric mixing and deposition rates can be determined from their measurement. Therefore, Pacific Northwest Laboratory began the continuous measurement of the atmospheric concentrations of a wide spectrum of radionuclides produced by nuclear weapons, nuclear reactors, cosmic rays, and radon and thoron decay. This report will discuss the concentrations of the longer-lived radionuclides (T 1/2 > 12 days). The concentrations of shorter-lived radionuclides measured following Chinese nuclear tests since 1972 are discussed in another report.

  9. CORRELATIONS OF PERSONAL EXPOSURE TO PARTICLES WITH OUTDOOR AIR MEASUREMENT: A REVIEW OF RECENT STUDIES

    EPA Science Inventory

    Epidemiological studies have found a correlation between daily mortality and particle concentrations in outdoor air as measured at a central monitoring station. These studies have been the central reason for the U.S. EPA to propose new tighter particle standards. However, perso...

  10. Evaluation of Length-of-Stain Gas Indicator Tubes for Measuring Carbon Monoxide in Air.

    ERIC Educational Resources Information Center

    Klaubert, Earl C.; And Others

    Techniques for detection and measurement of carbon monoxide (CO) in air are of interest and utility in many aspects of automotive safety. CO concentrations may range from less than 100 parts per million (ppm), or 0.01 percent, to about 10 percent by volume. Gas indicator tubes have been used for many years primarily as detectors of hazardous gases…

  11. Direct measurement of surface carbon concentrations. [in lunar soil

    NASA Technical Reports Server (NTRS)

    Filleux, C.; Tombrello, T. A.; Burnett, D. S.

    1977-01-01

    Measurements of surface concentrations of carbon in lunar soils and soil breccias provide information on the origin of carbon in the regolith. The reaction C-12 (d, p sub zero) is used to measure 'surface' and 'volume' concentrations in lunar samples. This method has a depth resolution of 1 micron, which permits only a 'surface' and a 'volume' component to be measured. Three of four Apollo 16 double drive tube samples show a surface carbon concentration of about 8 by 10 to the 14th power/sq cm, whereas the fourth sample gave 4 by 10 to the 14th power/sq cm. It can be convincingly shown that the measured concentration does not originate from fluorocarbon or hydrocarbon contaminants. Surface adsorbed layers of CO or CO2 are removed by a sputter cleaning procedure using a 2-MeV F beam. It is shown that the residual C concentration of 8 by 10 to the 14th power/sq cm cannot be further reduced by increased F fluence, and it is therefore concluded that it is truly lunar. If one assumes that the measured surface C concentration is a steady-state concentration determined only by a balance between solar-wind implantation and sputtering, a sputter erosion rate of 0.1 A/yr is obtained. However, it would be more profitable to use an independently derived sputter erosion rate to test the hypothesis of a solar-wind origin of the surface carbon.

  12. Preliminary assessment of BTEX concentrations in indoor air of residential buildings and atmospheric ambient air in Ardabil, Iran

    NASA Astrophysics Data System (ADS)

    Hazrati, Sadegh; Rostami, Roohollah; Farjaminezhad, Manoochehr; Fazlzadeh, Mehdi

    2016-05-01

    BTEX concentrations in indoor and outdoor air of 50 homes were studied in Ardabil city and their influencing parameters including; heating system, using gas stove and samovar, tobacco smoking, the floors in which the monitored homes were located, and kitchen plan were considered in the study. Risk assessment analysis was carried out with the obtained concentrations based on EPA IRIS reference doses. BTEX compounds were sampled by charcoal tubes and the samples were analyzed by a GC-FID. Concentrations of benzene (15.18 μg/m3 vs. 8.65 μg/m3), toluene (69.70 μg/m3 vs. 40.56 μg/m3), ethylbenzene (12.07 μg/m3 vs. 4.92 μg/m3) and xylene (48.08 μg/m3 vs. 7.44 μg/m3) in indoor air were significantly (p < 0.05) higher than the levels quantified for outdoor air. The obtained concentrations of benzene were considerably higher than the recommended value of 5 μg/m3 established by Iran environmental protection organization. Among the BTEX compounds, benzene (HQ = 0.51) and xylene (HQ = 0.47) had notable hazard quotient and were the main pollutants responsible for high hazard index in the monitored homes (HI = 1.003). The results showed considerably high cancer risk for lifetime exposure to the indoor (125 × 10-6) and outdoor (71 × 10-6) benzene. Indoor benzene concentrations in homes were significantly influenced by type of heating system, story, and natural gas appliances.

  13. [Genetic programming used for the measurement of CO concentration based on nondispersive infrared absorption spectroscopy].

    PubMed

    Chen, Jin; Duan, Fa-jie; Tong, Ying; Gao, Qiang

    2011-07-01

    Nondispersive infrared absorption spectroscopy(NDIR) is an important method to measure CO concentration in the air. In the present study, an open-path measurement system and continuous measuring device was developed, and genetic programming was used to establish the calibration model of subjects' light intensity sampling values. Continuous measurements were carried out in 10 different concentration of CO, and 40 sampled data were acquired and analyzed. For validation set, the correlation coefficient was 0.9997. The biggest relative error of validation was 4.00%, and the average relative error was 1.11%. Results show that genetic programming can be a good method for the modeling of gas concentration measurements equipped with NDIR systems.

  14. Measurements of air contaminants during the Cerro Grande fire at Los Alamos National Laboratory

    SciTech Connect

    Eberhart, Craig

    2010-08-01

    Ambient air sampling for radioactive air contaminants was continued throughout the Cerro Grande fire that burned part of Los Alamos National Laboratory. During the fire, samples were collected more frequently than normal because buildup of smoke particles on the filters was decreasing the air flow. Overall, actual sampling time was 96% of the total possible sampling time for the May 2000 samples. To evaluate potential human exposure to air contaminants, the samples were analyzed as soon as possible and for additional specific radionuclides. Analyses showed that the smoke from the fire included resuspended radon decay products that had been accumulating for many years on the vegetation and the forest floor that burned. Concentrations of plutonium, americium, and depleted uranium were also measurable, but at locations and concentrations comparable to non-fire periods. A continuous particulate matter sampler measured concentrations that exceeded the National Ambient Air Quality Standard for PM-10 (particles less than 10 micrometers in diameter). These high concentrations were caused by smoke from the fire when it was close to the sampler.

  15. MEASUREMENT OF LOW LEVEL AIR TOXICS WITH MODIFIED UV DOAS

    EPA Science Inventory

    To further understand near source impacts, EPA is working to develop open-path optical techniques for spatiotemporal-resolved measurement of air pollutants. Of particular interest is near real time quantification of mobile-source generated CO, Nox and hydrocarbons measured in cl...

  16. An intercomparison of measurement systems for vapor and particulate phase concentrations of formic and acetic acids

    NASA Technical Reports Server (NTRS)

    Keene, William C.; Talbot, Robert W.; Andreae, Meinrat O.; Beecher, Kristene; Berresheim, Harold

    1989-01-01

    During June 1986, eight systems for measuring vapor phase and four for measuring particulate phase concentrations of formic acid (HCOOH) and acetic acid (CH3COOH) were intercompared in central Virginia. HCOOH and CH3COOH vapors were sampled by condensate, mist, Chromosorb 103 GC resin, NaOH-coated annular denuders, NaOH-impregnated quartz filters, K2CO3 and NaCO3-impregnated cellulose filters, and Nylasorb membranes. Atmospheric aerosol was collected on Teflon and Nuclepore filters using both hi-vol and lo-vol systems to measure particulate phase concentrations. Performances of the mist chamber and K2CO3-impregnated filter techniques were evaluated using zero air and ambient air spiked with HCOOH(g) and CH3COOH(g), and formaldehyde from permeation sources. The advantages and drawbacks of these methods are reported and discussed.

  17. Concentration, temperature, and density in a hydrogen-air flame by excimer-induced Raman scattering

    NASA Technical Reports Server (NTRS)

    Wehrmeyer, Joseph A.; Bowling, John M.; Pitz, Robert W.

    1988-01-01

    Single-pulse, vibrational Raman scattering (VRS) is an attractive laser diagnostic for the study of supersonic hydrogen-air combustion. The VRS technique gives a complete thermodynamic description of the gas mixture at a point in the reacting flow. Single-pulse, vibrational Raman scattering can simultaneously provide independent measurements of density, temperature, and concentration of each major species (H2, H2O, O2 and N2) in a hydrogen/air turbulent combustor. Also the pressure can be calculated using the ideal gas law. However, single-pulse VRS systems in current use for measurement of turbulent combustion have a number of shortcomings when applied to supersonic flows: (1) slow repetition rate (1 to 5 Hz), (2) poor spatial resolution (0.5x0.3x0.3 cu mm), and (3) marginal time resolution. Most of these shortcomings are due to the use of visible wavelength flash-lamp pumped dye lasers. The advent of UV excimer laser allows the possibility of dramatic improvements in the single-pulse, vibrational Raman scattering. The excimer based VRS probe will greatly improve repetition rate (100 to 500 Hz), spatial resolution (0.1x0.1x0.1 cu mm) and time resolution (30ns). These improvements result from the lower divergence of the UV excimer, higher repetition rate, and the increased Raman cross-sections (15 to 20 times higher) at ultra-violet (UV) wavelengths. With this increased capability, single-pulse vibrational Raman scattering promises to be an ideal non-intrusive probe for the study of hypersonic propulsion flows.

  18. Measurement of formaldehyde concentrations in a subatmospheric steam-formaldehyde autoclave.

    PubMed Central

    Marcos, D; Wiseman, D

    1979-01-01

    A method has been developed for measuring formaldehyde concentrations in a subatmospheric steam-formaldehyde autoclave. Data obtained using this method indicate that the concentration of formaldehyde in the chamber atmosphere is not homogeneous and that it decreases rapidly with time. The penetration of formaldehyde vapour into narrow tubes has also been investigated and was shown to be dependent on the length-to-bore ratio of the tubes. The formaldehyde concentration within the tubes could be increased by using a lower vacuum in the air removal stage at the beginning of the cycle. PMID:572833

  19. [Concentrations and influencing factors of gaseous polycyclic aromatic hydrocarbons in residential air in Beijing].

    PubMed

    Wei, Zhi-cheng; Chang, Biao; Qiu, Wei-xun; Wang, Yi; Wu, Shi-min; Xing, Bao-shan; Liu, Wen-xin; Tao, Shu

    2007-09-01

    7 gas phase PAHs components in indoor air collected from 38 families were investigated by modified passive air samplers in Beijing areas during the local heating and non-heating seasons, and the influencing factors were discussed as well. The analytical results indicate that the gasous PAHs in local indoor air are dominated by 2 and 3 rings compounds, the mean concentrations for the 7 individual gaseous components range from 1 to 40 ng/m3, and the average concentration of total gaseous PAHs is about 100 ng/m3. There is no significant difference in total gaseous PAHs concentrations between the heating and the non-heating seasons, while some apparent seasonal changes occur in ACY and FLA concentrations. Compared with heating season, contribution of 2 rings compounds decreases while the proportions of 3 and 4 rings species increase during the non-heating season. Based on household activity questionnaires and actual analytical concentrations, the main influencing factors accounted for gaseous PAHs in indoor air, identified by multifactor analysis of variance, include cigarette smoking, use of moth ball, intensity of draft, cuisine frequency and built age.

  20. Measurements of radon concentrations in Spa waters in Amasya, Turkey

    NASA Astrophysics Data System (ADS)

    Yigitoglu, I.; Oner, F.; Yalim, H. A.; Ucar, B.

    2016-04-01

    The aim of this study is to determine the radon concentrations in thermal waters in the Amasya basin in Turkey and to explore the relationship between radon anomalies and active geological faults. The radon concentration measurements were performed in four thermal Spas around Amasya basin. The water samples were collected from tap waters in thermal water sources. The obtained radon concentrations ranged from 0.15 ± 0.12 to 0.71 ± 0.32 BqL-1 for Spa waters. The relationship between the radon concentration anomalies and earthquakes that occurred in the sampling period are discussed.

  1. Using a choice experiment to measure the environmental costs of air pollution impacts in Seoul.

    PubMed

    Yoo, Seung-Hoon; Kwak, Seung-Jun; Lee, Joo-Suk

    2008-01-01

    Air pollution, a by-product of economic growth, has been incurring extensive environmental costs in Seoul, Korea. Unfortunately, air pollution impacts are not treated as a commercial item, and thus it is difficult to measure the environmental costs arising from air pollution. There is an imminent need to find a way to measure air pollution impacts so that appropriate actions can be taken to control air pollution. Therefore, this study attempts to apply a choice experiment to quantifying the environmental costs of four air pollution impacts (mortality, morbidity, soiling damage, and poor visibility), using a specific case study of Seoul. We consider the trade-offs between price and attributes of air pollution impacts for selecting a preferred alternative and derive the marginal willingness to pay (WTP) estimate for each attribute. According to the results, the households' monthly WTP for a 10% reduction in the concentrations of major pollutants in Seoul was found to be approximately 5494 Korean won (USD 4.6) and the total annual WTP for the entire population of Seoul was about 203.4 billion Korean won (USD 169.5 million). This study is expected to provide policy-makers with useful information for evaluating and planning environmental policies relating specifically to air pollution.

  2. Workplace aerosol mass concentration measurement using optical particle counters.

    PubMed

    Görner, Peter; Simon, Xavier; Bémer, Denis; Lidén, Göran

    2012-02-01

    Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM® 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO®) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions

  3. Workplace aerosol mass concentration measurement using optical particle counters.

    PubMed

    Görner, Peter; Simon, Xavier; Bémer, Denis; Lidén, Göran

    2012-02-01

    Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM® 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO®) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions

  4. Dual-Pump Coherent Anti-Stokes Raman Scattering Temperature and CO2 Concentration Measurements

    NASA Technical Reports Server (NTRS)

    Lucht, Robert P.; Velur-Natarajan, Viswanathan; Carter, Campbell D.; Grinstead, Keith D., Jr.; Gord, James R.; Danehy, Paul M.; Fiechtner, G. J.; Farrow, Roger L.

    2003-01-01

    Measurements of temperature and CO2 concentration using dual-pump coherent anti-Stokes Raman scattering, (CARS) are described. The measurements were performed in laboratory flames,in a room-temperature gas cell, and on an engine test stand at the U.S. Air Force Research Laboratory, Wright-Patterson Air Force Base. A modeless dye laser, a single-mode Nd:YAG laser, and an unintensified back-illuminated charge-coupled device digital camera were used for these measurements. The CARS measurements were performed on a single-laser-shot basis. The standard deviations of the temperatures and CO2 mole fractions determined from single-shot dual-pump CARS spectra in steady laminar propane/air flames were approximately 2 and 10% of the mean values of approximately 2000 K and 0.10, respectively. The precision and accuracy of single-shot temperature measurements obtained from the nitrogen part of the dual-pump CARS system were investigated in detail in near-adiabatic hydrogen/air/CO2 flames. The precision of the CARS temperature measurements was found to be comparable to the best results reported in the literature for conventional two-laser, single-pump CARS. The application of dual-pump CARS for single-shot measurements in a swirl-stabilized combustor fueled with JP-8 was also demonstrated.

  5. Comparative analysis of radon, thoron and thoron progeny concentration measurements

    PubMed Central

    Janik, Miroslaw; Tokonami, Shinji; Kranrod, Chutima; Sorimachi, Atsuyuki; Ishikawa, Tetsuo; Hosoda, Masahiro; Mclaughlin, James; Chang, Byung-Uck; Kim, Yong Jae

    2013-01-01

    This study examined correlations between radon, thoron and thoron progeny concentrations based on surveys conducted in several different countries. For this purpose, passive detectors developed or modified by the National Institute of Radiological Sciences (NIRS) were used. Radon and thoron concentrations were measured using passive discriminative radon-thoron detectors. Thoron progeny measurements were conducted using the NIRS-modified detector, originally developed by Zhuo and Iida. Weak correlations were found between radon and thoron as well as between thoron and thoron progeny. The statistical evaluation showed that attention should be paid to the thoron equilibrium factor for calculation of thoron progeny concentrations based on thoron measurements. In addition, this evaluation indicated that radon, thoron and thoron progeny were independent parameters, so it would be difficult to estimate the concentration of one from those of the others. PMID:23297318

  6. Polarized radio emission from extensive air showers measured with LOFAR

    SciTech Connect

    Schellart, P.; Buitink, S.; Corstanje, A.; Enriquez, J.E.; Falcke, H.; Hörandel, J.R.; Krause, M.; Nelles, A.; Rachen, J.P.; Veen, S. ter; Thoudam, S.

    2014-10-01

    We present LOFAR measurements of radio emission from extensive air showers. We find that this emission is strongly polarized, with a median degree of polarization of nearly 99%, and that the angle between the polarization direction of the electric field and the Lorentz force acting on the particles, depends on the observer location in the shower plane. This can be understood as a superposition of the radially polarized charge-excess emission mechanism, first proposed by Askaryan and the geomagnetic emission mechanism proposed by Kahn and Lerche. We calculate the relative strengths of both contributions, as quantified by the charge-excess fraction, for 163 individual air showers. We find that the measured charge-excess fraction is higher for air showers arriving from closer to the zenith. Furthermore, the measured charge-excess fraction also increases with increasing observer distance from the air shower symmetry axis. The measured values range from (3.3± 1.0)% for very inclined air showers at 25 m to (20.3± 1.3)% for almost vertical showers at 225 m. Both dependencies are in qualitative agreement with theoretical predictions.

  7. Industrial sources influence air concentrations of hydrogen sulfide and sulfur dioxide in rural areas of western Canada.

    PubMed

    Burstyn, Igor; Senthilselvan, Ambikaipakan; Kim, Hyang-Mi; Cherry, Nicola M; Pietroniro, Elise; Waldner, Cheryl

    2007-10-01

    A survey of monthly average concentrations of sulfur dioxide (SO2) and hydrogen sulfide (H2S) at rural locations in western Canada (provinces of Alberta, British Columbia, and Saskatchewan) was conducted in 2001-2002, as part of an epidemiological study of the effects of oil and gas industry emissions on the health of cattle. Repeated measurements were obtained at some months and locations. We aimed to develop statistical models of the effect of oil and gas infrastructure on air concentrations. The regulatory authorities supplied the information on location of the different oil and gas facilities during the study period and, for Alberta, provided data on H2S content of wells and flaring volumes. Linear mixed effects models were used to relate observed concentrations to proximity and type of oil and gas infrastructure. Low concentrations were recorded; the monthly geometric mean was 0.1-0.2 ppb for H2S, and 0.3-1.3 ppb for SO2. Substantial variability between repeated measurements was observed. The precision of the measurement method was 0.005 ppb for both contaminants. There were seasonal trends in the concentrations, but the spatial variability was greater. This was explained, in part, by proximity to oil/gas/bitumen wells and (for SO2) gas plants. Wells within 2 km of monitoring stations had the greatest impact on measured concentrations. For H2S, 8% of between-location variability was explained by proximity to industrial sources of emissions; for SO2 this proportion was 18%. In Alberta, proximity to sour gas wells and flares was associated with elevated H2S concentrations; however, the estimate of the effect of sour gas wells in the immediate vicinity of monitoring stations was unstable. Our study was unable to control for all possible sources of the contaminants. However, the results suggest that oil and gas extraction activities contribute to air pollution in rural areas of western Canada. PMID:17972769

  8. Occupational dimethylformamide exposure. 1. Diffusive sampling of dimethylformamide vapor for determination of time-weighted average concentration in air.

    PubMed

    Yasugi, T; Kawai, T; Mizunuma, K; Horiguchi, S; Iguchi, H; Ikeda, M

    1992-01-01

    A diffusive sampling method with water as absorbent was examined in comparison with 3 conventional methods of diffusive sampling with carbon cloth as absorbent, pumping through National Institute of Occupational Safety and Health (NIOSH) charcoal tubes, and pumping through NIOSH silica gel tubes to measure time-weighted average concentration of dimethylformamide (DMF). DMF vapors of constant concentrations at 3-110 ppm were generated by bubbling air at constant velocities through liquid DMF followed by dilution with fresh air. Both types of diffusive samplers could either absorb or adsorb DMF in proportion to time (0.25-8 h) and concentration (3-58 ppm), except that the DMF adsorbed was below the measurable amount when carbon cloth samplers were exposed at 3 ppm for less than 1 h. When both diffusive samplers were loaded with DMF and kept in fresh air, the DMF in water samplers stayed unchanged for at least for 12 h. The DMF in carbon cloth samplers showed a decay with a half-time of 14.3 h. When the carbon cloth was taken out immediately after termination of DMF exposure, wrapped in aluminum foil, and kept refrigerated, however, there was no measurable decrease in DMF for at least 3 weeks. When the air was drawn at 0.2 l/min, a breakthrough of the silica gel tube took place at about 4,000 ppm.min (as the lower 95% confidence limit), whereas charcoal tubes could tolerate even heavier exposures, suggesting that both tubes are fit to measure the 8-h time-weighted average of DMF at 10 ppm. PMID:1577523

  9. The impact of European legislative and technology measures to reduce air pollutants on air quality, human health and climate

    NASA Astrophysics Data System (ADS)

    Turnock, S. T.; Butt, E. W.; Richardson, T. B.; Mann, G. W.; Reddington, C. L.; Forster, P. M.; Haywood, J.; Crippa, M.; Janssens-Maenhout, G.; Johnson, C. E.; Bellouin, N.; Carslaw, K. S.; Spracklen, D. V.

    2016-02-01

    European air quality legislation has reduced emissions of air pollutants across Europe since the 1970s, affecting air quality, human health and regional climate. We used a coupled composition-climate model to simulate the impacts of European air quality legislation and technology measures implemented between 1970 and 2010. We contrast simulations using two emission scenarios; one with actual emissions in 2010 and the other with emissions that would have occurred in 2010 in the absence of technological improvements and end-of-pipe treatment measures in the energy, industrial and road transport sectors. European emissions of sulphur dioxide, black carbon (BC) and organic carbon in 2010 are 53%, 59% and 32% lower respectively compared to emissions that would have occurred in 2010 in the absence of legislative and technology measures. These emission reductions decreased simulated European annual mean concentrations of fine particulate matter (PM2.5) by 35%, sulphate by 44%, BC by 56% and particulate organic matter by 23%. The reduction in PM2.5 concentrations is calculated to have prevented 80 000 (37 000-116 000, at 95% confidence intervals) premature deaths annually across the European Union, resulting in a perceived financial benefit to society of US232 billion annually (1.4% of 2010 EU GDP). The reduction in aerosol concentrations due to legislative and technology measures caused a positive change in the aerosol radiative effect at the top of atmosphere, reduced atmospheric absorption and also increased the amount of solar radiation incident at the surface over Europe. We used an energy budget approximation to estimate that these changes in the radiative balance have increased European annual mean surface temperatures and precipitation by 0.45 ± 0.11 °C and by 13 ± 0.8 mm yr-1 respectively. Our results show that the implementation of European legislation and technological improvements to reduce the emission of air pollutants has improved air quality and human

  10. Radical Concentrations and Prompt NO Formation in Hydrocarbon-Air Premixed Flames

    NASA Astrophysics Data System (ADS)

    Matusi, Yasuji; Yuuki, Akimasa

    1985-05-01

    Hydroxyl radical concentrations in laminar, premixed CH4-air flat-flames were measured by a conventional absorption method in the flame temperature range T{=}2200-1700 K. The OH mole fractions in the reaction zone POH were found to be insensitive to the flame temperature and the maximum POH to be about 6× 10-3 at T{=}2000 K in a stoichiometric flame. The rate constant for the prompt NO formation, CH+N2→HCN+N\\dashrightarrow2NO (4), is modified as k4{=}1.2× 1012\\exp (-13600/RT) by the relation between the amount of prompt NO and the saturation ion current Is. It is also shown from the measurements of NOx, unburnt hydrocarbons H.C., and Is, that the chemical kinetics are not significantly influenced by the flame temperature, and NO emission is reduced by reactions among NO, H.C., and N-containing intermediate species in low-temperature flames, even in stoichiometric and fuel-lean mixtures.

  11. Device for measuring the total concentration of oxygen in gases

    DOEpatents

    Isaacs, Hugh S.; Romano, Anthony J.

    1977-01-01

    This invention provides a CO equilibrium in a device for measuring the total concentration of oxygen impurities in a fluid stream. To this end, the CO equilibrium is produced in an electrochemical measuring cell by the interaction of a carbon element in the cell with the chemically combined and uncombined oxygen in the fluid stream at an elevated temperature.

  12. Measuring Outdoor Air Intake Rates into Existing Building

    SciTech Connect

    Fisk, William; Sullivan, Douglas; Cohen, Sebastian; Han, Hwataik

    2009-04-16

    Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10 percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15 percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100 percent, and were often greater than 25 percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

  13. Low-frequency sound absorption measurements in air

    NASA Technical Reports Server (NTRS)

    Zuckerwar, A. J.; Meredith, R. W.

    1984-01-01

    Thirty sets of sound absorption measurements in air at a pressure of 1 atmosphere are presented at temperatures from 10 C to 50 C, relative humidities from 0 to 100 percent, and frequencies from 10 to 2500 Hz. The measurements were conducted by the method of free decay in a resonant tube having a length of 18.261 m and bore diameter of 0.152 m. Background measurements in a gas consisting of 89.5 percent N2 and 10.5 percent Ar, a mixture which has the same sound velocity as air, permitted the wall and structural losses of the tube to be separated from the constituent absorption, consisting of classical rotational and vibrational absorption, in the air samples. The data were used to evaluate the vibrational relaxation frequencies of N2 and/or O2 for each of the 30 sets of meteorological parameters. Over the full range of humidity, the measured relaxation frequencies of N2 in air lie between those specified by ANSI Standard S1.26-1978 and those measured earlier in binary N2H2O mixtures. The measured relaxation frequencies could be determined only at very low values of humidity, reveal a significant trend away from the ANSI standard, in agreement with a prior investigation.

  14. Reflective measurement of water concentration using millimeter wave illumination

    NASA Astrophysics Data System (ADS)

    Sung, Shijun; Bennett, David; Taylor, Zachary; Bajwa, Neha; Tewari, Priyamvada; Maccabi, Ashkan; Culjat, Martin; Singh, Rahul; Grundfest, Warren

    2011-04-01

    THz and millimeter wave technology have shown the potential to become a valuable medical imaging tool because of its sensitivity to water and safe, non-ionizing photon energy. Using the high dielectric constant of water in these frequency bands, reflectionmode THz sensing systems can be employed to measure water content in a target with high sensitivity. This phenomenology may lead to the development of clinical systems to measure the hydration state of biological targets. Such measurements may be useful in fast and convenient diagnosis of conditions whose symptoms can be characterized by changes in water concentration such as skin burns, dehydration, or chemical exposure. To explore millimeter wave sensitivity to hydration, a reflectometry system is constructed to make water concentration measurements at 100 GHz, and the minimum detectable water concentration difference is measured. This system employs a 100 GHz Gunn diode source and Golay cell detector to perform point reflectivity measurements of a wetted polypropylene towel as it dries on a mass balance. A noise limited, minimum detectable concentration difference of less than 0.5% by mass can be detected in water concentrations ranging from 70% to 80%. This sensitivity is sufficient to detect hydration changes caused by many diseases and pathologies and may be useful in the future as a diagnostic tool for the assessment of burns and other surface pathologies.

  15. Determination of benzene, toluene and xylene concentration in humid air using differential ion mobility spectrometry and partial least squares regression.

    PubMed

    Maziejuk, M; Szczurek, A; Maciejewska, M; Pietrucha, T; Szyposzyńska, M

    2016-05-15

    Benzene, toluene and xylene (BTX compounds) are chemicals of greatest concern due to their impact on humans and the environment. In many cases, quantitative information about each of these compounds is required. Continuous, fast-response analysis, performed on site would be desired for this purpose. Several methods have been developed to detect and quantify these compounds in this way. Methods vary considerably in sensitivity, accuracy, ease of use and cost-effectiveness. The aim of this work is to show that differential ion mobility spectrometry (DMS) may be applied for determining concentration of BTX compounds in humid air. We demonstrate, this goal is achievable by applying multivariate analysis of the measurement data using partial least squares (PLS) regression. The approach was tested at low concentrations of these compounds in the range of 5-20 ppm and for air humidity in a range 0-12 g/kg. These conditions correspond to the foreseeable application of the developed approach in occupational health and safety measurements. The average concentration assessment error was about 1 ppm for each: benzene, toluene and xylene. We also successfully determined water vapor content in air. The error achieved was 0.2 g/kg. The obtained results are very promising regarding further development of DMS technique as well as its application.

  16. Monitor of the concentration of particles of dense radioactive materials in a stream of air

    DOEpatents

    Yule, Thomas J.

    1979-01-01

    A monitor of the concentration of particles of radioactive materials such as plutonium oxide in diameters as small as 1/2 micron includes in combination a first stage comprising a plurality of virtual impactors, a second stage comprising a further plurality of virtual impactors, a collector for concentrating particulate material, a radiation detector disposed near the collector to respond to radiation from collected material and means for moving a stream of air, possibly containing particulate contaminants, through the apparatus.

  17. Indoor air quality. [Health hazards due to energy conservation measures

    SciTech Connect

    Hollowell, C.D.

    1981-06-01

    Rising energy prices, among other factors, have generated an incentive to reduce ventilation rates and thereby reduce the cost of heating and cooling buildings. Reduced ventilation in buildings may significantly increase exposure to indoor air pollution and perhaps have adverse effects on occupant health and comfort. Preliminary findings suggest that reduced ventilation may adversely affect indoor air quality unless appropriate control strategies are undertaken. The strategies used to control indoor air pollution depend on the specific pollutant or class of pollutants encountered, and differ somewhat depending on whether the application is to an existing building or a new building under design and construction. Whenever possible, the first course of action is prevention or reduction of pollutant emissions at the source. In most buildings, control measures involve a combination of prevention, removal, and suppression. Common sources of indoor air pollution in buildings, the specific pollutants emitted by each source, the potential health effects, and possible control techniques are discussed.

  18. Radiocarbon tracer measurements of atmospheric hydroxyl radical concentrations

    NASA Technical Reports Server (NTRS)

    Campbell, M. J.; Farmer, J. C.; Fitzner, C. A.; Henry, M. N.; Sheppard, J. C.

    1986-01-01

    The usefulness of the C-14 tracer in measurements of atmospheric hydroxyl radical concentration is discussed. The apparatus and the experimental conditions of three variations of a radiochemical method of atmosphere analysis are described and analyzed: the Teflon bag static reactor, the flow reactor (used in the Wallops Island tests), and the aircraft OH titration reactor. The procedure for reduction of the aircraft reactor instrument data is outlined. The problems connected with the measurement of hydroxyl radicals are discussed. It is suggested that the gas-phase radioisotope methods have considerable potential in measuring tropospheric impurities present in very low concentrations.

  19. Application of hybrid coagulation microfiltration with air backflushing to direct sewage concentration for organic matter recovery.

    PubMed

    Jin, Zhengyu; Gong, Hui; Wang, Kaijun

    2015-01-01

    The idea of sewage concentration is gradually being accepted as a promising and sustainable way of wastewater resource recovery. In this study, Hybrid coagulation microfiltration (HCM) with air backflushing (AB) was investigated to effectively concentrate organic matter. Compared to direct sewage microfiltration, the addition of coagulation process improved the filtration performance with less fouling trends and better concentration efficiency. The use of AB exhibited even better performance within the same 7-h preliminary concentration period by reducing to one tenth of the resistance and collecting around four times as much organic matter into the product concentrate as in direct sewage microfiltration. During 93-h lab-scale continuous concentration by HCM with AB, a product concentrate with the COD concentration over 15,000 mg/L was achieved and around 70% of total influent organic matter could be recovered. Compared to Direct Membrane Filtration (DMF) with Chemically Enhanced Backwash (CEB), HCM with AB achieved better concentration efficiency with higher concentration extent and concentration velocity along with less organic matter mineralization and the more concentrated product despite with lower organic matter retention. HCM with AB could be a promising effective sewage organic matter concentration for resource recovery under optimization.

  20. A Comparison of Statistical Techniques for Combining Modeled and Observed Concentrations to Create High-Resolution Ozone Air Quality Surfaces

    EPA Science Inventory

    Air quality surfaces representing pollutant concentrations across space and time are needed for many applications, including tracking trends and relating air quality to human and ecosystem health. The spatial and temporal characteristics of these surfaces may reveal new informat...

  1. Drop size distribution and air velocity measurements in air assist swirl atomizer sprays

    NASA Technical Reports Server (NTRS)

    Mao, C.-P.; Oechsle, V.; Chigier, N.

    1987-01-01

    Detailed measurements of mean drop size (SMD) and size distribution parameters have been made using a Fraunhofer diffraction particle sizing instrument in a series of sprays generated by an air assist swirl atomizer. Thirty-six different combinations of fuel and air mass flow rates were examined with liquid flow rates up to 14 lbm/hr and atomizing air flow rates up to 10 lbm/hr. Linear relationships were found between SMD and liquid to air mass flow rate ratios. SMD increased with distance downstream along the center line and also with radial distance from the axis. Increase in obscuration with distance downstream was due to an increase in number density of particles as the result of deceleration of drops and an increase in the exposed path length of the laser beam. Velocity components of the atomizing air flow field measured by a laser anemometer show swirling jet air flow fields with solid body rotation in the core and free vortex flow in the outer regions.

  2. Effect of geocoding errors on traffic-related air pollutant exposure and concentration estimates

    EPA Science Inventory

    Exposure to traffic-related air pollutants is highest very near roads, and thus exposure estimates are sensitive to positional errors. This study evaluates positional and PM2.5 concentration errors that result from the use of automated geocoding methods and from linearized approx...

  3. Modeling and Impacts of Traffic Emissions on Air Toxics Concentrations near Roadways

    EPA Science Inventory

    The dispersion formulation incorporated in the U.S. Environmental Protection Agency’s AERMOD regulatory dispersion model is used to estimate the contribution of traffic-generated emissions of select VOCs – benzene, 1,3-butadiene, toluene – to ambient air concentrations at downwin...

  4. Assessment of near-source air pollution at a fine spatial scale utilizing a mobile measurement platform approach

    EPA Science Inventory

    Mobile monitoring is an emerging strategy to characterize spatially and temporally variable air pollution in areas near sources. EPA’s Geospatial Monitoring of Air Pollution (GMAP) vehicle, an all-electric vehicle measuring real-time concentrations of particulate and gaseous poll...

  5. Urban air measurements using PTR-MS in Tokyo area and comparison with GC-FID measurements

    NASA Astrophysics Data System (ADS)

    Kato, Shungo; Miyakawa, Yuko; Kaneko, Tatsuya; Kajii, Yoshizumi

    2004-07-01

    Ambient air at a suburban area in Tokyo was measured by proton transfer reaction mass spectrometry (PTR-MS) and GC-FID simultaneously. Good correlations were obtained for hydrocarbon concentrations between GC-FID and PTR-MS, but concentrations differed by factor of 0.52-2.15, depending on the hydrocarbon. This shows that the calculated PTR-MS data needs to be corrected by standard gas measurements. Isoprene measured by PTR-MS is influenced by other species and the results of isoprene is not reliable at low concentration. Oxygenated volatile organic carbons showed higher concentrations during summer than in fall. This reflects the enhanced photochemical reactivity in summer. On the other hand, aromatic hydrocarbons, emitted mainly from car exhaust, did not show a difference between summer and fall. The ratios of aromatic hydrocarbons can be used as an indicator of photochemical reaction. Enhanced photochemical reactions were expected from these ratios during summer.

  6. Ozone concentrations and damage for realistic future European climate and air quality scenarios

    NASA Astrophysics Data System (ADS)

    Hendriks, Carlijn; Forsell, Nicklas; Kiesewetter, Gregor; Schaap, Martijn; Schöpp, Wolfgang

    2016-11-01

    Ground level ozone poses a significant threat to human health from air pollution in the European Union. While anthropogenic emissions of precursor substances (NOx, NMVOC, CH4) are regulated by EU air quality legislation and will decrease further in the future, the emissions of biogenic NMVOC (mainly isoprene) may increase significantly in the coming decades if short-rotation coppice plantations are expanded strongly to meet the increased biofuel demand resulting from the EU decarbonisation targets. This study investigates the competing effects of anticipated trends in land use change, anthropogenic ozone precursor emissions and climate change on European ground level ozone concentrations and related health and environmental impacts until 2050. The work is based on a consistent set of energy consumption scenarios that underlie current EU climate and air quality policy proposals: a current legislation case, and an ambitious decarbonisation case. The Greenhouse Gas-Air Pollution Interactions and Synergies (GAINS) integrated assessment model was used to calculate air pollutant emissions for these scenarios, while land use change because of bioenergy demand was calculated by the Global Biosphere Model (GLOBIOM). These datasets were fed into the chemistry transport model LOTOS-EUROS to calculate the impact on ground level ozone concentrations. Health damage because of high ground level ozone concentrations is projected to decline significantly towards 2030 and 2050 under current climate conditions for both energy scenarios. Damage to plants is also expected to decrease but to a smaller extent. The projected change in anthropogenic ozone precursor emissions is found to have a larger impact on ozone damage than land use change. The increasing effect of a warming climate (+2-5 °C across Europe in summer) on ozone concentrations and associated health damage, however, might be higher than the reduction achieved by cutting back European ozone precursor emissions. Global

  7. Online measurement of urea concentration in spent dialysate during hemodialysis

    NASA Astrophysics Data System (ADS)

    Olesberg, Jonathon T.; Armitage, Ben; Arnold, Mark A.; Flanigan, Michael

    2002-05-01

    We describe on-line optical measurements of urea concentration during the regular hemodialysis treatment of several patients. The spectral measurements were performed in the effluent dialysate stream after the dialysis membrane using an FTIR spectrometer equipped with a flow-through cell. Spectra were recorded across the 5000-4000 cm-1 (2.0-2.5 micrometers at 1-minute intervals. Optically determined concentrations matched concentrations obtained from standard chemical assays with a root-mean-square error of 0.29 mM for urea (0.8 mg/dl urea nitrogen), 0.03 mM for creatinine, 0.11 mM for lactate, and 0.22 mM for glucose. The observed concentration ranges were 0-11 mM for urea, 0-0.35 mM for creatinine, 0-0.75 mM for lactate, and 9-12.5 mM for glucose.

  8. Measurement of air toxics using extractive FTIR spectroscopy

    SciTech Connect

    Lacoss, J.P.; Ogle, L.D.; Shareef, G.S.

    1995-12-31

    In response to the 1990 Clean Air Act Amendments, the Gas Research Institute (GRI) is investigating air toxics emissions from natural gas industry sources. Included in this effort are measurements from internal combustion engines, one of the source categories targeted by U.S. Environmental Protection Agency (EPA) for development of maximum achievable control technology (MACT) based regulations by the year 2000. Formaldehyde and other aldehydes are the air toxics potentially present in engine exhaust. Since there are no EPA approved methods available for quantifying aldehydes in engine exhaust, GRI initiated a field test to validate an extractive Fourier transform infrared spectroscopy (FTIR) based method according to U.S. EPA Method 301 {open_quotes}Field Validation of Pollutant Measurement Methods for Various Media{close_quotes}. The extended paper presents the results of this validation testing for formaldehyde, acetaldehyde, and acrolein conducted to support this validation testing.

  9. Total internal reflection-based planar waveguide solar concentrator with symmetric air prisms as couplers.

    PubMed

    Xie, Peng; Lin, Huichuan; Liu, Yong; Li, Baojun

    2014-10-20

    We present a waveguide coupling approach for planar waveguide solar concentrator. In this approach, total internal reflection (TIR)-based symmetric air prisms are used as couplers to increase the coupler reflectivity and to maximize the optical efficiency. The proposed concentrator consists of a line focusing cylindrical lens array over a planar waveguide. The TIR-based couplers are located at the focal line of each lens to couple the focused sunlight into the waveguide. The optical system was modeled and simulated with a commercial ray tracing software (Zemax). Results show that the system used with optimized TIR-based couplers can achieve 70% optical efficiency at 50 × geometrical concentration ratio, resulting in a flux concentration ratio of 35 without additional secondary concentrator. An acceptance angle of ± 7.5° is achieved in the x-z plane due to the use of cylindrical lens array as the primary concentrator.

  10. AIRNET Data from Los Alamos National Laboratory: Air Concentration Data by Site and Isotope/Element

    DOE Data Explorer

    Ambient monitoring is the systematic, long-term assessment of pollutant levels by measuring the quantity and types of certain pollutants in the surrounding, outdoor air. The purpose of AIRNET, LANL's ambient air monitoring network, is to monitor locations where people live or work. The community of Los Alamos is downwind from LANL, so there are many monitoring stations in and around the town. AIRNET stations monitor 24 hours a day, 365 days of the year. Particulates are collected on a filter and analyzed every two weeks for identification of analytes and assessment of the potential impact on the public. Emissions measurement is the process of monitoring materials vented from buildings. Air samples are taken from building exhaust units, called stacks, and are then analyzed for particulate matter, tritium, and radioactive gases and vapors. A computer model uses the emission data to determine the dispersion. Stack monitoring is also used to measure emissions that cannot be measured by AIRNET stations.

  11. Short-term temperature-dependent air-surface exchange and atmospheric concentrations of polychlorinated naphthalenes and organochlorine pesticides

    SciTech Connect

    Lee, R.G.M.; Burnett, V.; Harner, T.; Jones, K.C.

    2000-02-01

    Atmospheric concentrations of five organochlorine (OC) pesticides, some of which have been banned for a number of years, and polychlorinated naphthalenes (PCNs) were measured at a U.K. site over periods of 6 h for 7 days resulting in 28 samples. Mean concentrations of the pesticides were {alpha}-HCH 90 pg m{sup {minus}3}, {gamma}-HCH 500, {rho},{rho}{prime}-DDE 8, dieldrin 63, endrin 22, and HCB 39. PCN mean homologue concentrations were {sub 3}CNs 67 pg m{sup {minus}3}, {sub 4}CNs 78, {sub 5}CNs 5, {sub 6}CNs 0.6, {sub 7}CNs 0.6, and {Sigma}PCNs 152. TEQ concentrations for those PCNs ascribed TEF values ranged between 0.36 and 3.6 fg m{sup {minus}3} which corresponds to {approximately}3.0--30% of the TEQ concentrations of PCDD/Fs at the same site. All the compounds measured, except HCB, exhibited a strong temperature-dependent diurnal cycling. Results from Clausius-Clapeyron plots show that pesticide concentrations were controlled by temperature-driven air-surface recycling throughout the first 5 days when stable atmospheric conditions were dominant, while during the last 2 days advection became more influential as more unstable and cooler weather started to influence the site. PCN concentrations were controlled primarily by a mixture of recycling and advection throughout the first 5 days and then by advection in the final 2 days, suggesting that there are ongoing emissions from diffuse point sources of PCNs into the U.K. atmosphere. This study provides further evidence of the rapid air-surface exchange of semivolatile organic compounds (SOCs) and shows how different factors alone or in combination can produce rapid changes in the atmospheric concentrations of past and present SOCs.

  12. Deposition and air concentrations of permethrin and naled used for adult mosquito management.

    PubMed

    Schleier, Jerome J; Peterson, Robert K D

    2010-01-01

    One of the most effective ways of managing adult mosquitoes that vector human and animal pathogens is the use of ultra-low-volume (ULV) insecticides. Because of the lack of environmental fate studies and concerns about the safety of the insecticides used for the management of adult mosquitoes, we conducted an environmental fate study after truck-mounted applications of permethrin and naled. One hour after application, concentrations of permethrin on cotton dosimeters placed at ground level 25, 50, and 75 m from the spray source were 2, 4, and 1 ng/cm2 in 2007 and 5, 2, and 0.9 ng/cm2 in 2008, respectively. One hour after application, concentrations of naled 25, 50, and 75 m were 47, 66, and 67 ng/cm2 in 2007 and 15, 6.1, and 0 (nondetectable) ng/cm2 in 2008, respectively. Deposition concentrations 12 h after application were not significantly different than 1 h after application for permethrin and naled either year. During 2007 and 2008 permethrin applications, two quantifiable air concentrations of 375 and 397 ng/m3 were observed 1 h after application. In 2007 and 2008, naled air concentrations ranged from 2300 to 4000 ng/m3 1 h after application. There were no quantifiable air concentrations between 1 and 12 h after application in either 2007 or 2008 for both naled and permethrin. Environmental concentrations observed in this study demonstrate that models used in previous risk assessments were sufficiently conservative (i.e., the models overestimated environmental concentrations). However, we also demonstrate inadequacies of models such as AgDrift and AGDISP, which currently are used by the US Environmental Protection Agency to estimate environmental concentrations of ULV insecticides. PMID:19536586

  13. Monte Carlo study of TLD measurements in air cavities.

    PubMed

    Haraldsson, Pia; Knöös, Tommy; Nyström, Håkan; Engström, Per

    2003-09-21

    Thermoluminescent dosimeters (TLDs) are used for verification of the delivered dose during IMRT treatment of head and neck carcinomas. The TLDs are put into a plastic tube, which is placed in the nasal cavities through the treated volume. In this study, the dose distribution to a phantom having a cylindrical air cavity containing a tube was calculated by Monte Carlo methods and the results were compared with data from a treatment planning system (TPS) to evaluate the accuracy of the TLD measurements. The phantom was defined in the DOSXYZnrc Monte Carlo code and calculations were performed with 6 MV fields, with the TLD tube placed at different positions within the cylindrical air cavity. A similar phantom was defined in the pencil beam based TPS. Differences between the Monte Carlo and the TPS calculations of the absorbed dose to the TLD tube were found to be small for an open symmetrical field. For a half-beam field through the air cavity, there was a larger discrepancy. Furthermore, dose profiles through the cylindrical air cavity show, as expected, that the treatment planning system overestimates the absorbed dose in the air cavity. This study shows that when using an open symmetrical field, Monte Carlo calculations of absorbed doses to a TLD tube in a cylindrical air cavity give results comparable to a pencil beam based treatment planning system.

  14. Measurement of indoor radon concentration in kindergartens in Sofia, Bulgaria.

    PubMed

    Ivanova, Kremena; Stojanovska, Zdenka; Tsenova, Martina; Badulin, Viktor; Kunovska, Bistra

    2014-11-01

    As a part of the systematic survey of indoor radon in Bulgaria, the indoor radon concentration was measured in 296 kindergarten buildings of Sofia city during 3 months (February to April 2013) using the CR-39 nuclear tract detectors. In 256 buildings at least two frequently occupied rooms (mainly playrooms) were observed. Altogether, 922 measurements were performed. The frequency distribution was well described by the lognormal function. The measured radon concentrations range between 9 and 1415 Bq m(-3) with a geometric mean of 101 Bq m(-3) (2.08) and an arithmetic mean 132 Bq m(-3) with a standard deviation of 118 Bq m(-3). The radon concentrations obtained in this survey were compared with that in Sofia city dwellings obtained from a previous study. A detailed statistical analysis of the building factors was presented.

  15. A measure of the concentration of rare events

    NASA Astrophysics Data System (ADS)

    Prieto Curiel, Rafael; Bishop, Steven

    2016-08-01

    We introduce here an index, which we call the Rare Event Concentration Coefficient (RECC), that is a measure of the dispersion/concentration of events which have a low frequency but tend to have a high level of concentration, such as the number of crimes suffered by a person. The Rare Event Concentration Coefficient is a metric based on a statistical mixture model, with a value closer to zero meaning that events are homogeneously distributed, and a value closer to one meaning that the events have a higher degree of concentration. This measure may be used to compare the concentration of events over different time periods and over different regions. Other traditional approaches for the dispersion/concentration of a variable tend to be blind to structural changes in the pattern of occurrence of rare events. The RECC overcomes this issue and we show here two simple applications, first by using the number of burglaries suffered in Netherlands and then by using the number of volcanic eruptions in the world.

  16. A measure of the concentration of rare events.

    PubMed

    Prieto Curiel, Rafael; Bishop, Steven

    2016-01-01

    We introduce here an index, which we call the Rare Event Concentration Coefficient (RECC), that is a measure of the dispersion/concentration of events which have a low frequency but tend to have a high level of concentration, such as the number of crimes suffered by a person. The Rare Event Concentration Coefficient is a metric based on a statistical mixture model, with a value closer to zero meaning that events are homogeneously distributed, and a value closer to one meaning that the events have a higher degree of concentration. This measure may be used to compare the concentration of events over different time periods and over different regions. Other traditional approaches for the dispersion/concentration of a variable tend to be blind to structural changes in the pattern of occurrence of rare events. The RECC overcomes this issue and we show here two simple applications, first by using the number of burglaries suffered in Netherlands and then by using the number of volcanic eruptions in the world. PMID:27577532

  17. A measure of the concentration of rare events

    PubMed Central

    Prieto Curiel, Rafael; Bishop, Steven

    2016-01-01

    We introduce here an index, which we call the Rare Event Concentration Coefficient (RECC), that is a measure of the dispersion/concentration of events which have a low frequency but tend to have a high level of concentration, such as the number of crimes suffered by a person. The Rare Event Concentration Coefficient is a metric based on a statistical mixture model, with a value closer to zero meaning that events are homogeneously distributed, and a value closer to one meaning that the events have a higher degree of concentration. This measure may be used to compare the concentration of events over different time periods and over different regions. Other traditional approaches for the dispersion/concentration of a variable tend to be blind to structural changes in the pattern of occurrence of rare events. The RECC overcomes this issue and we show here two simple applications, first by using the number of burglaries suffered in Netherlands and then by using the number of volcanic eruptions in the world. PMID:27577532

  18. Summary of stationary and personal air sampling measurements made during a plutonium glovebox decommissioning project.

    SciTech Connect

    Munyon, W. J.; Lee, M. B.

    2002-02-01

    Workplace air sampling was performed during the decommissioning of a previously active plutonium glovebox facility located at Argonne National Laboratory. Personal air samplers (PAS) were used to measure breathing zone activity concentrations of workers engaged in size-reducing contaminated gloveboxes. Stationary air samplers (SAS) were used to measure the work area activity concentrations and test their application in providing representative sampling of breathing zone activity concentrations. The relative response of these samplers (PAS:SAS) was tracked during the course of the decommissioning work, with results yielding favorable agreement to within a factor of {+-}5. A cascade impactor was used to determine the particle size distribution of workplace aerosols. The average activity median aerodynamic diameter (AMAD) was estimated to be 3.0 {mu}m, with a corresponding geometric standard deviation of 2.4. A gas-flow proportional counter was utilized to measure the gross alpha activity collected on both the SAS glass fiber and the PAS cellulose fiber filters. A subset of this filter group was subsequently analyzed using an alpha spectrometer post radiochemical processing and isotopic separation. The quantity of alpha activity measured on the SAS filters was generally within {+-}30% of the alpha spectrometry measurements. However, measurements made of the activity present on the PAS cellulose fiber filters were consistently underestimated using a gas-flow proportional counter, suggesting a small correction factor of 15-20% to account for the absorption of alpha particle emissions.

  19. Summary of stationary and personal air sampling measurements made during a plutonium glovebox decommissioning project.

    PubMed

    Munyon, W J; Lee, M B

    2002-02-01

    Workplace air sampling was performed during the decommissioning of a previously active plutonium glovebox facility located at Argonne National Laboratory. Personal air samplers (PAS) were used to measure breathing zone activity concentrations of workers engaged in size-reducing contaminated gloveboxes. Stationary air samplers (SAS) were used to measure the work area activity concentrations and test their application in providing representative sampling of breathing zone activity concentrations. The relative response of these samplers (PAS:SAS) was tracked during the course of the decommissioning work, with results yielding favorable agreement to within a factor of +/-5. A cascade impactor was used to determine the particle size distribution of workplace aerosols. The average activity median aerodynamic diameter (AMAD) was estimated to be 3.0 microm, with a corresponding geometric standard deviation of 2.4. A gas-flow proportional counter was utilized to measure the gross alpha activity collected on both the SAS glass fiber and the PAS cellulose fiber filters. A subset of this filter group was subsequently analyzed using an alpha spectrometer post radiochemical processing and isotopic separation. The quantity of alpha activity measured on the SAS filters was generally within +/-30% of the alpha spectrometry measurements. However, measurements made of the activity present on the PAS cellulose fiber filters were consistently underestimated using a gas-flow proportional counter, suggesting a small correction factor of 15-20% to account for the absorption of alpha particle emissions.

  20. Disruptive Innovation in Air Measurement Technology: Reality or Hype?

    EPA Science Inventory

    This presentation is a big picture overview on the changing state of air measurement technology in the world, with a focus on the introduction of low-cost sensors into the market place. The presentation discusses how these new technologies may be a case study in disruptive innov...

  1. Continuous Quantitative Measurements on a Linear Air Track

    ERIC Educational Resources Information Center

    Vogel, Eric

    1973-01-01

    Describes the construction and operational procedures of a spark-timing apparatus which is designed to record the back and forth motion of one or two carts on linear air tracks. Applications to measurements of velocity, acceleration, simple harmonic motion, and collision problems are illustrated. (CC)

  2. METHOD FOR MEASURING AIR-IMMISCIBLE LIQUID PARTITION COEFFICIENTS

    EPA Science Inventory

    The principal objective of this work was to measure nonaqueous phase liquid-air partition coefficients for various gas tracer compounds. Known amounts of trichloroethene (TCE) and tracer, as neat compounds, were introduced into glass vials and allowed to equilibrate. The TCE and ...

  3. Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

    SciTech Connect

    Sherman, Max; Sherman, Max H.; Walker, Iain S.

    2008-05-01

    The purpose of ventilation is dilute or remove indoor contaminants that an occupant is exposed to. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. Most US homes have central HVAC systems, which tend to mix the air thus the indoor conditions between zones. Different types of ventilation systems will provide different amounts of exposure depending on the effectiveness of their air distribution systems and the location of sources and occupants. This paper will report on field measurements using a unique multi-tracer measurement system that has the capacity to measure not only the flow of outdoor air to each zone, but zone-to-zone transport. The paper will derive seven different metrics for the evaluation of air distribution. Measured data from two homes with different levels of natural infiltration will be used to evaluate these metrics for three different ASHRAE Standard 62.2 compliant ventilation systems. Such information can be used to determine the effectiveness of different systems so that appropriate adjustments can be made in residential ventilation standards such as ASHRAE Standard 62.2.

  4. Temperature Measurement in Microhollow Cathode Discharges in Atmospheric Air

    NASA Astrophysics Data System (ADS)

    Block, Rolf; Toedter, Olaf; Schoenbach, Karl H.

    1998-10-01

    By reducing the diameter of the cathode opening in hollow cathode discharge geometry to values on the order of one hundred micrometers we were able to operate the discharges in a direct current mode at atmospheric pressure in air. The possibility to operate microhollow cathode discharges (MHCD) in parallel [1] in atmospheric air opens a wide range of applications. At atmospheric pressures, the electric power of a single discharge was measured as 8W. The power density in the microhollow exceeds 1MW/cm^3. This leads to strong thermal loading of the electrodes. In order to study the thermal properties of the discharge we have used a method based on emission spectroscopy. The rotational structure of the emitted lines corresponding to the second positive system of nitrogen contains information on the neutral gas temperature. Taking the apparatus profile into account the temperature of the rotational excited molecules can be estimated by a comparison of simulated and measured data. Measurements on MHCD up to atmospheric pressure show an increase in the neutral gas temperature to values exceeding 1000K. In addition to the gas temperature the electrode temperatures were measured and the thermodynamic behavior of the electrode configuration was calculated. [1] W. Shi, K.H. Schoenbach Parallel Operation of Microhollow Cathode Discharges, ICOPS98, Raleigh, NC, USA, 1998 This work was funded by the Air Force Office of Scientific Research (AFOSR) in cooperation with the DDR&E Air Plasma Ramparts MURI program, and by the Department of Energy, Advanced Energy Division.

  5. Measuring concentrations of volatile organic compounds in vinyl flooring.

    PubMed

    Cox, S S; Little, J C; Hodgson, A T

    2001-08-01

    The initial solid-phase concentration of volatile organic compounds (VOCs) is a key parameter influencing the emission characteristics of many indoor materials. Solid-phase measurements are typically made using solvent extraction or thermal headspace analysis. The high temperatures and chemical solvents associated with these methods can modify the physical structure of polymeric materials and, consequently, affect mass transfer characteristics. To measure solid-phase concentrations under conditions resembling those in which the material would be installed in an indoor environment, a new technique was developed for measuring VOC concentrations in vinyl flooring (VF) and similar materials. A 0.09-m2 section of new VF was punched randomly to produce -200 0.78-cm2 disks. The disks were milled to a powder at -140 degrees C to simultaneously homogenize the material and reduce the diffusion path length without loss of VOCs. VOCs were extracted from the VF particles at room temperature by fluidized-bed desorption (FBD) and by direct thermal desorption (DTD) at elevated temperatures. The VOCs in the extraction gas from FBD and DTD were collected on sorbent tubes and analyzed by gas chromatography/mass spectrometry (GC/MS). Seven VOCs emitted by VF were quantified. Concentration measurements by FBD ranged from 5.1 microg/g VF for n-hexadecane to 130 microg/g VF for phenol. Concentrations measured by DTD were higher than concentrations measured by FBD. Differences between FBD and DTD results may be explained using free-volume and dual-mobility sorption theory, but further research is necessary to more completely characterize the complex nature of a diffusant in a polymer matrix. PMID:11518293

  6. Rapid Ammonia Deposition Measured Near Concentrated Animal Feeding Operations

    NASA Astrophysics Data System (ADS)

    Stanton, L. G.; Pan, D.; Sun, K.; Golston, L.; Tao, L.; Zondlo, M. A.

    2014-12-01

    Concentrated animal feeding operations (CAFOs) emit massive amounts of ammonia (NH3) to the atmosphere. Current measurements of NH3 are generally conducted far away from the sources (satellites, airplanes, etc.). There is insufficient knowledge about the dry deposition rate of NH3 near the sources, which might contribute to the large discrepancies between measured concentrations at CAFOs and those from models. During the 2014 NASA DISCOVER-AQ campaign, we designed a series of tests to measure the deposition rate of NH3 by utilizing a suite of sensors, including a LICOR LI-7700 methane sensor and Princeton University's custom open path NH3 sensor, which was mounted on top of a small SUV. Our mobile sampling technique enables us to follow feedlot emission plumes to see how ambient NH3 concentration decays as gases moves away from the CAFO. The mobile platform is used to perform upwind and downwind sampling to characterize the NH3 emission source. We tracked the change of the enhancement of NH3 concentration relative to the enhancement of CH4 concentration (ΔNH3:ΔCH4), while transecting the plume of individual cattle feedlots. Measured data shows that the high concentration of NH3 seen at the source decreases quickly as one moves further downwind from it. A time constant of approximately ten minutes has been calculated from the decay of the ΔNH3:ΔCH4 ratios while moving away from the sources. We also will compare our measurements with those of NASA's P-3B aerosol measurements to show that the majority must be lost to dry deposition. This rapid deposition suggests that large amounts of NH3 are being deposited in very close proximity to these CAFOs, which is consistent with previous findings of locally high soil pH near NH3 sources. Our results will be used to better characterize nitrogen deposition from cattle feedlots and estimate NH3 lifetime.

  7. Measuring concentrations of volatile organic compounds in vinyl flooring.

    PubMed

    Cox, S S; Little, J C; Hodgson, A T

    2001-08-01

    The initial solid-phase concentration of volatile organic compounds (VOCs) is a key parameter influencing the emission characteristics of many indoor materials. Solid-phase measurements are typically made using solvent extraction or thermal headspace analysis. The high temperatures and chemical solvents associated with these methods can modify the physical structure of polymeric materials and, consequently, affect mass transfer characteristics. To measure solid-phase concentrations under conditions resembling those in which the material would be installed in an indoor environment, a new technique was developed for measuring VOC concentrations in vinyl flooring (VF) and similar materials. A 0.09-m2 section of new VF was punched randomly to produce -200 0.78-cm2 disks. The disks were milled to a powder at -140 degrees C to simultaneously homogenize the material and reduce the diffusion path length without loss of VOCs. VOCs were extracted from the VF particles at room temperature by fluidized-bed desorption (FBD) and by direct thermal desorption (DTD) at elevated temperatures. The VOCs in the extraction gas from FBD and DTD were collected on sorbent tubes and analyzed by gas chromatography/mass spectrometry (GC/MS). Seven VOCs emitted by VF were quantified. Concentration measurements by FBD ranged from 5.1 microg/g VF for n-hexadecane to 130 microg/g VF for phenol. Concentrations measured by DTD were higher than concentrations measured by FBD. Differences between FBD and DTD results may be explained using free-volume and dual-mobility sorption theory, but further research is necessary to more completely characterize the complex nature of a diffusant in a polymer matrix.

  8. Chlorinated paraffins in indoor air and dust: concentrations, congener patterns, and human exposure.

    PubMed

    Fridén, Ulrika E; McLachlan, Michael S; Berger, Urs

    2011-10-01

    Chlorinated paraffins (CPs) are large production volume chemicals used in a wide variety of commercial applications. They are ubiquitous in the environment and humans. Human exposure via the indoor environment has, however, been barely investigated. In the present study 44 indoor air and six dust samples from apartments in Stockholm, Sweden, were analyzed for CPs, and indoor air concentrations are reported for the first time. The sumCP concentration (short chain CPs (SCCPs) and medium chain CPs (MCCPs)) in air ranged from <5-210 ng m(-3) as quantified by gas chromatography coupled to electron ionization tandem mass spectrometry (GC/EI-MS/MS). Congener group patterns were studied using GC with electron capture negative ionization MS (GC/ECNI-MS). The air samples were dominated by the more volatile SCCPs compared to MCCPs. SumCPs were quantified by GC/EI-MS/MS in the dust samples at low μg g(-1) levels, with a chromatographic pattern suggesting the prevalence of longer chain CPs compared to air. The median exposure to sumCPs via the indoor environment was estimated to be ~1 μg day(-1) for both adults and toddlers. Adult exposure was dominated by inhalation, while dust ingestion was suggested to be more important for toddlers. Comparing these results to literature data on dietary intake indicates that human exposure to CPs from the indoor environment is not negligible. PMID:21612825

  9. Cross-validation of the osmotic pressure based on Pitzer model with air humidity osmometry at high concentration of ammonium sulfate solutions.

    PubMed

    Wang, Xiao-Lan; Zhan, Ting-Ting; Zhan, Xian-Cheng; Tan, Xiao-Ying; Qu, Xiao-You; Wang, Xin-Yue; Li, Cheng-Rong

    2014-01-01

    The osmotic pressure of ammonium sulfate solutions has been measured by the well-established freezing point osmometry in dilute solutions and we recently reported air humidity osmometry in a much wider range of concentration. Air humidity osmometry cross-validated the theoretical calculations of osmotic pressure based on the Pitzer model at high concentrations by two one-sided test (TOST) of equivalence with multiple testing corrections, where no other experimental method could serve as a reference for comparison. Although more strict equivalence criteria were established between the measurements of freezing point osmometry and the calculations based on the Pitzer model at low concentration, air humidity osmometry is the only currently available osmometry applicable to high concentration, serves as an economic addition to standard osmometry.

  10. Poly-silicon nanowire sensor for sodium chloride concentration measurement.

    PubMed

    Kan, Yao-Chiang; Hsu, Cheng-Chih; Ho, Wen-Kai; Wu, Tsai-Chen; Ho, Yao-Yaun; Yang, Chia Yu

    2014-01-01

    In this paper, the poly-Si nanowire sensor was fabricated by top-down technique for sodium chloride concentration measurement. The results showed that the smallest threshold voltage and the best resolution were 1.65 V and 0.41 μM, respectively. Furthermore, the sensor can be reused more than 50 times which maintained acceptable performance and showed good linearity of the calibration within wide range of the concentration. Based on these results, it can be concluded that the proposed sensor has great potential to be used for measuring complicated sample with suitable modification on the surface of nanowires.

  11. Measurement of radon concentrations at Super-Kamiokande

    NASA Astrophysics Data System (ADS)

    Takeuchi, Y.; Okumura, K.; Kajita, T.; Tasaka, S.; Nemoto, M.; Fukuda, Y.; Okazawa, H.; Hayakawa, T.; Ishihara, K.; Ishino, H.; Itow, Y.; Kameda, J.; Kasuga, S.; Kobayashi, K.; Kobayashi, Y.; Koshio, Y.; Miura, M.; Nakahata, M.; Nakayama, S.; Obayashi, Y.; Okada, A.; Sakurai, N.; Shiozawa, M.; Suzuki, Y.; Takeuchi, H.; Totsuka, Y.; Yamada, S.; Earl, M.; Habig, A.; Kearns, E.; Messier, M. D.; Scholberg, K.; Stone, J. L.; Sulak, L. R.; Walter, C. W.; Goldhaber, M.; Barszczak, T.; Casper, D.; Gajewski, W.; Kropp, W. R.; Mine, S.; Price, L. R.; Smy, M.; Sobel, H. W.; Vagins, M. R.; Ganezer, K. S.; Keig, W. E.; Ellsworth, R. W.; Kibayashi, A.; Learned, J. G.; Matsuno, S.; Stenger, V. J.; Takemori, D.; Ishii, T.; Kanzaki, J.; Kobayashi, T.; Nakamura, K.; Nishikawa, K.; Oyama, Y.; Sakai, A.; Sakuda, M.; Sasaki, O.; Echigo, S.; Kohama, M.; Suzuki, A. T.; Haines, T. J.; Blaufuss, E.; Kim, B. K.; Sanford, R.; Svoboda, R.; Chen, M. L.; Goodman, J. A.; Sullivan, G. W.; Hill, J.; Jung, C. K.; Martens, K.; Mauger, C.; McGrew, C.; Sharkey, E.; Viren, B.; Yanagisawa, C.; Doki, W.; Kirisawa, M.; Inaba, S.; Miyano, K.; Saji, C.; Takahashi, M.; Takahata, M.; Higuchi, K.; Nagashima, Y.; Takita, M.; Yamaguchi, T.; Yoshida, M.; Kim, S. B.; Etoh, M.; Hasegawa, A.; Hasegawa, T.; Hatakeyama, S.; Inoue, K.; Iwamoto, T.; Koga, M.; Maruyama, T.; Ogawa, H.; Shirai, J.; Suzuki, A.; Tsushima, F.; Koshiba, M.; Hatakeyama, Y.; Koike, M.; Nishijima, K.; Fujiyasu, H.; Futagami, T.; Hayato, Y.; Kanaya, Y.; Kaneyuki, K.; Watanabe, Y.; Kielczewska, D.; George, J. S.; Stachyra, A. L.; Wai, L. L.; Wilkes, R. J.; Young, K. K.

    1999-04-01

    Radioactivity from radon is a major background for observing solar neutrinos at Super-Kamiokande. In this paper, we describe the measurement of radon concentrations at Super-Kamiokande, the method of radon reduction, and the radon monitoring system. The measurement shows that the current low-energy event rate between 5.0 MeV and 6.5 MeV implies a radon concentration in the Super-Kamiokande water of less than 1.4 mBq/m3.

  12. A Method for Estimating Urban Background Concentrations in Support of Hybrid Air Pollution Modeling for Environmental Health Studies

    PubMed Central

    Arunachalam, Saravanan; Valencia, Alejandro; Akita, Yasuyuki; Serre, Marc L.; Omary, Mohammad; Garcia, Valerie; Isakov, Vlad

    2014-01-01

    Exposure studies rely on detailed characterization of air quality, either from sparsely located routine ambient monitors or from central monitoring sites that may lack spatial representativeness. Alternatively, some studies use models of various complexities to characterize local-scale air quality, but often with poor representation of background concentrations. A hybrid approach that addresses this drawback combines a regional-scale model to provide background concentrations and a local-scale model to assess impacts of local sources. However, this approach may double-count sources in the study regions. To address these limitations, we carefully define the background concentration as the concentration that would be measured if local sources were not present, and to estimate these background concentrations we developed a novel technique that combines space-time ordinary kriging (STOK) of observations with outputs from a detailed chemistry-transport model with local sources zeroed out. We applied this technique to support an exposure study in Detroit, Michigan, for several pollutants (including NOx and PM2.5), and evaluated the estimated hybrid concentrations (calculated by combining the background estimates that addresses this issue of double counting with local-scale dispersion model estimates) using observations. Our results demonstrate the strength of this approach specifically by eliminating the problem of double-counting reported in previous hybrid modeling approaches leading to improved estimates of background concentrations, and further highlight the relative importance of NOx vs. PM2.5 in their relative contributions to total concentrations. While a key limitation of this approach is the requirement for another detailed model simulation to avoid double-counting, STOK improves the overall characterization of background concentrations at very fine spatial scales. PMID:25321872

  13. Biomimetic air sampling for detection of low concentrations of molecules and bioagents : LDRD 52744 final report.

    SciTech Connect

    Hughes, Robert Clark

    2003-12-01

    Present methods of air sampling for low concentrations of chemicals like explosives and bioagents involve noisy and power hungry collectors with mechanical parts for moving large volumes of air. However there are biological systems that are capable of detecting very low concentrations of molecules with no mechanical moving parts. An example is the silkworm moth antenna which is a highly branched structure where each of 100 branches contains about 200 sensory 'hairs' which have dimensions of 2 microns wide by 100 microns long. The hairs contain about 3000 pores which is where the gas phase molecules enter the aqueous (lymph) phase for detection. Simulations of diffusion of molecules indicate that this 'forest' of hairs is 'designed' to maximize the extraction of the vapor phase molecules. Since typical molecules lose about 4 decades in diffusion constant upon entering the liquid phase, it is important to allow air diffusion to bring the molecule as close to the 'sensor' as possible. The moth acts on concentrations as low as 1000 molecules per cubic cm. (one part in 1e16). A 3-D collection system of these dimensions could be fabricated by micromachining techniques available at Sandia. This LDRD addresses the issues involved with extracting molecules from air onto micromachined structures and then delivering those molecules to microsensors for detection.

  14. Technique for measuring air flow and carbon dioxide flux in large, open-top chambers

    SciTech Connect

    Ham, J.M.; Owensby, C.E.; Coyne, P.I.

    1993-10-01

    Open-Top Chambers (OTCs) are commonly used to evaluate the effect of CO{sub 2},O{sub 3}, and other trace gases on vegetation. This study developed and tested a new technique for measuring forced air flow and net CO{sub 2} flux from OTCs. Experiments were performed with a 4.5-m diam. OTC with a sealed floor and a specialized air delivery system. Air flow through the chamber was computed with the Bernoulli equation using measurements of the pressure differential between the air delivery ducts and the chamber interior. An independent measurement of air flow was made simultaneously to calibrate and verify the accuracy of the Bernoulli relationship. The CO{sub 2} flux density was calculated as the product of chamber air flow and the difference in CO{sub 2} concentration between the air entering and exhausting from the OTC (C{sub in}-C{sub out}). Accuracy was evaluated by releasing CO{sub 2} within the OTC at known rates. Data were collected with OTCs at ambient and elevated CO{sub 2} ({approx}700 {mu}mol{sup -1}). Results showed the Bernoulli equation, with a flow coefficient of 0.7, accurately measured air flow in the OTC within {+-}5% regardless of flow rate and air duct geometry. Experiments in ambient OTCs showed CO{sub 2} flux density ({mu}mol m{sup -2} s{sup -1}), computed from 2-min averages of air flow and C{sub in} - C{sub out,} was typically within {+-} 10% of actual flux, provided that the exit air velocity at the top of the OTC was greater than 0.6 m s{sup -1}. Obtaining the same accuracy in CO{sub 2}-enriched OTCs required a critical exit velocity near 1.2 m s{sup -1} to minimize the incursion of ambient air and prevent contamination of exit gas sample. When flux data were integrated over time to estimate daily CO{sub 2} flux ({mu}mol m{sup -2} d{sup -1}), actual and measured values agreed to within {+-}2% for both ambient and CO{sub 2}-enriched chambers, suggesting that accurate measurements of daily net C exchange are possible with this technique.

  15. Comparison of two different passive air samplers (PUF-PAS versus SIP-PAS) to determine time-integrated average air concentration of volatile hydrophobic organic pollutants

    NASA Astrophysics Data System (ADS)

    Kim, Seung-Kyu; Park, Jong-Eun

    2014-06-01

    Despite remarkable achievements with r some chemicals, a field-measurement technique has not been advanced for volatile hydrophobic organic chemicals (HOCs) that are the subjects of international concern. This study assesses the applicability of passive air sampling (PAS) by comparing PUF-PAS and its modified SIP-PAS which was made by impregnating XAD-4 powder into PUF, overviewing the principles of PAS, screening sensitive parameters, and determining the uncertainty range of PAS-derived concentration. The PAS air sampling rate determined in this study, corrected by a co-deployed low-volume active air sampler (LAS) for neutral PFCs as model chemicals, was ˜1.2 m3 day-1. Our assessment shows that the improved sorption capacity in a SIP lengthens PAS deployment duration by expanding the linear uptake range and then enlarges the effective air sampling volume and detection frequency of chemicals at trace level. Consequently, volatile chemicals can be collected during sufficiently long times without reaching equilibrium when using SIP, while this is not possible for PUF. The most sensitive parameter to influence PAS-derived CA was an air-side mass transfer coefficient (kA), implying the necessity of spiking depuration chemicals (DCs) because this parameter is strongly related with meteorological conditions. Uncertainty in partition coefficients (KPSM-A or KOA) influences PAS-derived CA to a greater extent with regard to lower KPSM-A chemicals. Also, the PAS-derived CA has an uncertainty range of a half level to a 3-fold higher level of the calculated one. This work is expected to establish solid grounds for the improvement of field measurement technique of HOCs.

  16. Probabilistic approach to estimating indoor air concentrations of chlorinated volatile organic compounds from contaminated groundwater: a case study in San Antonio, Texas.

    PubMed

    Johnston, Jill E; Gibson, Jacqueline MacDonald

    2011-02-01

    This paper describes a probabilistic model, based on the Johnson-Ettinger algorithm, developed to characterize the current and historic exposure to tricholorethylene (TCE) and tetrachlorethylene (PCE) in indoor air from plumes of groundwater contamination emanating from the former Kelly Air Force Base in San Antonio, Texas. We estimate indoor air concentration, house by house, in 30 101 homes and compare the estimated concentrations with measured values in a small subset of homes. We also compare two versions of the Johnson-Ettinger model: one used by the Environmental Protection Agency (EPA) and another based on an alternative parametrization. The modeled mean predicted PCE concentration historically exceeded PCE screening levels (0.41 ug/m(3)) in 5.5% of houses, and the 95th percentile of the predicted concentration exceeded screening levels in 85.3% of houses. For TCE, the mean concentration exceeded the screening level (0.25 ug/m(3)) in 49% of homes, and the 95th percentile of the predicted concentration exceeded the screening level in 99% of homes. The EPA model predicts slightly lower indoor concentrations than the alternative parametrization. Comparison with measured samples suggests both models, with the inputs selected, underestimate indoor concentrations and that the 95th percentiles of the predicted concentrations are closer to measured concentrations than predicted mean values.

  17. [Volatile organic compounds concentrations and sources inside new air-conditioned bus].

    PubMed

    You, Ke-Wei; Ge, Yun-Shan; Qian, Yi-Xin; Liu, Wei; Feng, Bo; Zhang, Yan-Ni; Ning, Zhan-Wu; Hu, Bin; Zhao, Shou-Tang

    2008-05-01

    The distributing profile and concentration level inside new air-conditioned buses with 53 seats have been determined using the method of thermal desorption-capillary GC/MS under vehicle static conditions. Compounds were identified from their mass spectral data by using US National Institute of Standards and Technology (NIST02). The total numbers of identified components were 33 inside buses, including alkenes (15,45.4%), aromatic compounds (9,27.3%), alcohols (4,12.1%), ketones (3,9.1%) and esters (2,6.1%), especially in the range of C6-C10. The top 5 compounds measured inside buses were decane (8.01 mg/m3), 3-methylhexane (7.10 mg/m3), heptane (5.10 mg/m3), isoheptane (4.20 mg/m3) and 1-Methyl-3-ethylbenzene (3.56 mg/m3), and total volatile organic compounds (TVOC) > 52.5 mg/m3. The main sources of in-vehicle hydrocarbons and aromatic compounds comes from cabin components and interior trim materials (e.g., sealants, carpets, adhesives, paints, leather, plastics, PU foam and PE foam) that may retain certain VOCs during manufacturing, and/or emit these compounds over an extended period of time from off-gassing, aging-related breakdown products, heating/cooling and so on.

  18. Simultaneous measurement of ventilation using tracer gas techniques and VOC concentrations in homes, garages and vehicles.

    PubMed

    Batterman, Stuart; Jia, Chunrong; Hatzivasilis, Gina; Godwin, Chris

    2006-02-01

    Air exchange rates and interzonal flows are critical ventilation parameters that affect thermal comfort, air migration, and contaminant exposure in buildings and other environments. This paper presents the development of an updated approach to measure these parameters using perfluorocarbon tracer (PFT) gases, the constant injection rate method, and adsorbent-based sampling of PFT concentrations. The design of miniature PFT sources using hexafluorotoluene and octafluorobenzene tracers, and the development and validation of an analytical GC/MS method for these tracers are described. We show that simultaneous deployment of sources and passive samplers, which is logistically advantageous, will not cause significant errors over multiday measurement periods in building, or over shorter periods in rapidly ventilated spaces like vehicle cabins. Measurement of the tracers over periods of hours to a week may be accomplished using active or passive samplers, and low method detection limits (<0.025 microg m(-3)) and high precisions (<10%) are easily achieved. The method obtains the effective air exchange rate (AER), which is relevant to characterizing long-term exposures, especially when ventilation rates are time-varying. In addition to measuring the PFT tracers, concentrations of other volatile organic compounds (VOCs) are simultaneously determined. Pilot tests in three environments (residence, garage, and vehicle cabin) demonstrate the utility of the method. The 4 day effective AER in the house was 0.20 h(-1), the 4 day AER in the attached garage was 0.80 h(-1), and 16% of the ventilation in the house migrated from the garage. The 5 h AER in a vehicle traveling at 100 km h(-1) under a low-to-medium vent condition was 92 h(-1), and this represents the highest speed test found in the literature. The method is attractive in that it simultaneously determines AERs, interzonal flows, and VOC concentrations over long and representative test periods. These measurements are

  19. Can changing the timing of outdoor air intake reduce indoor concentrations of traffic-related pollutants in schools?

    PubMed

    MacNeill, M; Dobbin, N; St-Jean, M; Wallace, L; Marro, L; Shin, T; You, H; Kulka, R; Allen, R W; Wheeler, A J

    2016-10-01

    Traffic emissions have been associated with a wide range of adverse health effects. Many schools are situated close to major roads, and as children spend much of their day in school, methods to reduce traffic-related air pollutant concentrations in the school environment are warranted. One promising method to reduce pollutant concentrations in schools is to alter the timing of the ventilation so that high ventilation time periods do not correspond to rush hour traffic. Health Canada, in collaboration with the Ottawa-Carleton District School Board, tested the effect of this action by collecting traffic-related air pollution data from four schools in Ottawa, Canada, during October and November 2013. A baseline and intervention period was assessed in each school. There were statistically significant (P < 0.05) reductions in concentrations of most of the pollutants measured at the two late-start (9 AM start) schools, after adjusting for outdoor concentrations and the absolute indoor-outdoor temperature difference. The intervention at the early-start (8 AM start) schools did not have significant reductions in pollutant concentrations. Based on these findings, changing the timing of the ventilation may be a cost-effective mechanism of reducing traffic-related pollutants in late-start schools located near major roads.

  20. Definition of air quality measurements for monitoring space shuttle launches

    NASA Technical Reports Server (NTRS)

    Thorpe, R. D.

    1978-01-01

    A description of a recommended air quality monitoring network to characterize the impact on ambient air quality in the Kennedy Space Center (KSC) (area) of space shuttle launch operations is given. Analysis of ground cloud processes and prevalent meteorological conditions indicates that transient HCl depositions can be a cause for concern. The system designed to monitor HCl employs an extensive network of inexpensive detectors combined with a central analysis device. An acid rain network is also recommended. A quantitative measure of projected minimal long-term impact involves the limited monitoring of NOx and particulates. All recommended monitoring is confined ti KSC property.

  1. Sequential Measurement of Intermodal Variability in Public Transportation PM2.5 and CO Exposure Concentrations.

    PubMed

    Che, W W; Frey, H Christopher; Lau, Alexis K H

    2016-08-16

    A sequential measurement method is demonstrated for quantifying the variability in exposure concentration during public transportation. This method was applied in Hong Kong by measuring PM2.5 and CO concentrations along a route connecting 13 transportation-related microenvironments within 3-4 h. The study design takes into account ventilation, proximity to local sources, area-wide air quality, and meteorological conditions. Portable instruments were compacted into a backpack to facilitate measurement under crowded transportation conditions and to quantify personal exposure by sampling at nose level. The route included stops next to three roadside monitors to enable comparison of fixed site and exposure concentrations. PM2.5 exposure concentrations were correlated with the roadside monitors, despite differences in averaging time, detection method, and sampling location. Although highly correlated in temporal trend, PM2.5 concentrations varied significantly among microenvironments, with mean concentration ratios versus roadside monitor ranging from 0.5 for MTR train to 1.3 for bus terminal. Measured inter-run variability provides insight regarding the sample size needed to discriminate between microenvironments with increased statistical significance. The study results illustrate the utility of sequential measurement of microenvironments and policy-relevant insights for exposure mitigation and management.

  2. Sequential Measurement of Intermodal Variability in Public Transportation PM2.5 and CO Exposure Concentrations.

    PubMed

    Che, W W; Frey, H Christopher; Lau, Alexis K H

    2016-08-16

    A sequential measurement method is demonstrated for quantifying the variability in exposure concentration during public transportation. This method was applied in Hong Kong by measuring PM2.5 and CO concentrations along a route connecting 13 transportation-related microenvironments within 3-4 h. The study design takes into account ventilation, proximity to local sources, area-wide air quality, and meteorological conditions. Portable instruments were compacted into a backpack to facilitate measurement under crowded transportation conditions and to quantify personal exposure by sampling at nose level. The route included stops next to three roadside monitors to enable comparison of fixed site and exposure concentrations. PM2.5 exposure concentrations were correlated with the roadside monitors, despite differences in averaging time, detection method, and sampling location. Although highly correlated in temporal trend, PM2.5 concentrations varied significantly among microenvironments, with mean concentration ratios versus roadside monitor ranging from 0.5 for MTR train to 1.3 for bus terminal. Measured inter-run variability provides insight regarding the sample size needed to discriminate between microenvironments with increased statistical significance. The study results illustrate the utility of sequential measurement of microenvironments and policy-relevant insights for exposure mitigation and management. PMID:27182735

  3. Effect of soil moisture on seasonal variation in indoor radon concentration: modelling and measurements in 326 Finnish houses.

    PubMed

    Arvela, H; Holmgren, O; Hänninen, P

    2016-02-01

    The effect of soil moisture on seasonal variation in soil air and indoor radon is studied. A brief review of the theory of the effect of soil moisture on soil air radon has been presented. The theoretical estimates, together with soil moisture measurements over a period of 10 y, indicate that variation in soil moisture evidently is an important factor affecting the seasonal variation in soil air radon concentration. Partitioning of radon gas between the water and air fractions of soil pores is the main factor increasing soil air radon concentration. On two example test sites, the relative standard deviation of the calculated monthly average soil air radon concentration was 17 and 26%. Increased soil moisture in autumn and spring, after the snowmelt, increases soil gas radon concentrations by 10-20 %. In February and March, the soil gas radon concentration is in its minimum. Soil temperature is also an important factor. High soil temperature in summer increased the calculated soil gas radon concentration by 14%, compared with winter values. The monthly indoor radon measurements over period of 1 y in 326 Finnish houses are presented and compared with the modelling results. The model takes into account radon entry, climate and air exchange. The measured radon concentrations in autumn and spring were higher than expected and it can be explained by the seasonal variation in the soil moisture. The variation in soil moisture is a potential factor affecting markedly to the high year-to-year variation in the annual or seasonal average radon concentrations, observed in many radon studies.

  4. A comparison of strategies for estimation of ultrafine particle number concentrations in urban air pollution monitoring networks.

    PubMed

    Reggente, Matteo; Peters, Jan; Theunis, Jan; Van Poppel, Martine; Rademaker, Michael; De Baets, Bernard; Kumar, Prashant

    2015-04-01

    We propose three estimation strategies (local, remote and mixed) for ultrafine particles (UFP) at three sites in an urban air pollution monitoring network. Estimates are obtained through Gaussian process regression based on concentrations of gaseous pollutants (NOx, O3, CO) and UFP. As local strategy, we use local measurements of gaseous pollutants (local covariates) to estimate UFP at the same site. As remote strategy, we use measurements of gaseous pollutants and UFP from two independent sites (remote covariates) to estimate UFP at a third site. As mixed strategy, we use local and remote covariates to estimate UFP. The results suggest: UFP can be estimated with good accuracy based on NOx measurements at the same location; it is possible to estimate UFP at one location based on measurements of NOx or UFP at two remote locations; the addition of remote UFP to local NOx, O3 or CO measurements improves models' performance.

  5. Concentrations and patterns of polychlorinated naphthalenes in urban air in Beijing, China.

    PubMed

    Xue, Lingnan; Zhang, Lifei; Yan, Yan; Dong, Liang; Huang, Yeru; Li, Xiaoxiu

    2016-11-01

    Air samples were collected, using a high-volume air sampler, at an urban site in Beijing from April 2014 to March 2015. The polychlorinated naphthalene (PCN) concentration in the atmosphere in each season was determined. The total PCN (total target tri- to octachloronaphthalene congeners) concentrations were 1.99-19.0 pg/m(3), and the mean was 7.20 pg/m(3). The PCN concentrations were higher in fall than summer, indicating that the concentrations varied significantly over time. The trichloronaphthalene homolog was the predominant PCN homolog in all four seasons. The PCN toxic equivalent (TEQ) concentrations were 0.42-6.89 fg/m(3), and the mean was 1.74 fg/m(3). The CN-66/67 and CN-73 congeners were the predominant contributors to the TEQ concentrations. The mean seasonal TEQ concentration decreased in the order fall (3.18 fg/m(3)) > winter (1.41 fg/m(3)) > summer (1.11 fg/m(3)) > spring (1.03 fg/m(3)). The TEQ concentrations and the PCN concentrations did not follow the same seasonal trends, but the highest TEQ and PCN concentrations were both found in fall. Correlation analysis, ratio analysis, and principal component analysis were used to investigate the sources of PCNs to the Beijing atmosphere. The results suggested that combustion processes may be the main sources of PCNs to the Beijing atmosphere.

  6. Concentrations and patterns of polychlorinated naphthalenes in urban air in Beijing, China.

    PubMed

    Xue, Lingnan; Zhang, Lifei; Yan, Yan; Dong, Liang; Huang, Yeru; Li, Xiaoxiu

    2016-11-01

    Air samples were collected, using a high-volume air sampler, at an urban site in Beijing from April 2014 to March 2015. The polychlorinated naphthalene (PCN) concentration in the atmosphere in each season was determined. The total PCN (total target tri- to octachloronaphthalene congeners) concentrations were 1.99-19.0 pg/m(3), and the mean was 7.20 pg/m(3). The PCN concentrations were higher in fall than summer, indicating that the concentrations varied significantly over time. The trichloronaphthalene homolog was the predominant PCN homolog in all four seasons. The PCN toxic equivalent (TEQ) concentrations were 0.42-6.89 fg/m(3), and the mean was 1.74 fg/m(3). The CN-66/67 and CN-73 congeners were the predominant contributors to the TEQ concentrations. The mean seasonal TEQ concentration decreased in the order fall (3.18 fg/m(3)) > winter (1.41 fg/m(3)) > summer (1.11 fg/m(3)) > spring (1.03 fg/m(3)). The TEQ concentrations and the PCN concentrations did not follow the same seasonal trends, but the highest TEQ and PCN concentrations were both found in fall. Correlation analysis, ratio analysis, and principal component analysis were used to investigate the sources of PCNs to the Beijing atmosphere. The results suggested that combustion processes may be the main sources of PCNs to the Beijing atmosphere. PMID:27497350

  7. Assessment of regional air quality by a concentration-dependent Pollution Permeation Index

    NASA Astrophysics Data System (ADS)

    Liang, Chun-Sheng; Liu, Huan; He, Ke-Bin; Ma, Yong-Liang

    2016-10-01

    Although air quality monitoring networks have been greatly improved, interpreting their expanding data in both simple and efficient ways remains challenging. Therefore, needed are new analytical methods. We developed such a method based on the comparison of pollutant concentrations between target and circum areas (circum comparison for short), and tested its applications by assessing the air pollution in Jing-Jin-Ji, Yangtze River Delta, Pearl River Delta and Cheng-Yu, China during 2015. We found the circum comparison can instantly judge whether a city is a pollution permeation donor or a pollution permeation receptor by a Pollution Permeation Index (PPI). Furthermore, a PPI-related estimated concentration (original concentration plus halved average concentration difference) can be used to identify some overestimations and underestimations. Besides, it can help explain pollution process (e.g., Beijing’s PM2.5 maybe largely promoted by non-local SO2) though not aiming at it. Moreover, it is applicable to any region, easy-to-handle, and able to boost more new analytical methods. These advantages, despite its disadvantages in considering the whole process jointly influenced by complex physical and chemical factors, demonstrate that the PPI based circum comparison can be efficiently used in assessing air pollution by yielding instructive results, without the absolute need for complex operations.

  8. BTEX in indoor air of waterpipe cafés: Levels and factors influencing their concentrations.

    PubMed

    Hazrati, Sadegh; Rostami, Roohollah; Fazlzadeh, Mehdi

    2015-08-15

    BTEX (benzene, toluene, ethylbenzene and xylene) concentrations, factors affecting their levels, and the exposure risks related to these compounds were studied in waterpipe (Ghalyun/Hookah) cafés of Ardabil city in Islamic Republic of Iran. 81 waterpipe cafés from different districts of Ardabil city were selected and their ambient air was monitored for BTEX compounds. Air samples were taken from standing breathing zone of employees, ~150 cm above the ground level, and were analyzed using GC-FID. In each case, the types of smoked tobacco (regular, fruit flavored), types of ventilation systems (natural/artificial), and the floor level at which the café was located were investigated. A high mean concentration of 4.96±2.63 mg/m(3) corresponding to long term exposure to benzene-related cancer risk of 4314×10(-6) was estimated. The levels of the remaining compounds were lower than the national guideline limits, but their hazard quotients (HQ) for long term exposure to ethylbenzene (1.15) and xylene (17.32) exceeded the HQ unit value. Total hazard indices (HI) of 63.23 were obtained for non-cancer risks. Type of the smoked tobacco was the most important factor influencing BTEX concentrations in the cafés. BTEX concentrations in indoor ambient air of Ardabil waterpipe cafés were noticeably high, and therefore may pose important risks for human health on both short and long term exposures. PMID:25912530

  9. Volatile organic compound concentrations in ambient air of Kaohsiung petroleum refinery in Taiwan

    NASA Astrophysics Data System (ADS)

    Lin, Tsai-Yin; Sree, Usha; Tseng, Sen-Hong; Chiu, Kong Hwa; Wu, Chien-Hou; Lo, Jiunn-Guang

    The air quality assessment for volatile organic compounds (VOC) was conducted in and around Chinese petroleum corporation (CPC) refinery at Kaohsiung, located in southern Taiwan, during 2001 by collecting air samples at 26 sites. Benzene and toluene were detected as the most abundant VOC by both gas chromatography and ultra-violet differential optical absorption spectroscopy (UV-DOAS) techniques. BTXE concentrations showed day and night variations at some of the sampling site. The highest among the 26 sites for total concentration of VOC at CPC was 2506 ppbv near waste burning stack. High concentrations of VOC were also detected at the wastewater management area and the east gate of the plant. The values were 10-18 times higher than those probed in Kaohsiung city. The meteorological parameters such as wind speed and direction played vital roles in the distribution of ambient air VOC concentrations and affected the petrochemical complex emissions. The application of UV-DOAS for online monitoring of criteria pollutants appears feasible though the accuracy of the technique is not fully controlled.

  10. Assessment of regional air quality by a concentration-dependent Pollution Permeation Index

    PubMed Central

    Liang, Chun-Sheng; Liu, Huan; He, Ke-Bin; Ma, Yong-Liang

    2016-01-01

    Although air quality monitoring networks have been greatly improved, interpreting their expanding data in both simple and efficient ways remains challenging. Therefore, needed are new analytical methods. We developed such a method based on the comparison of pollutant concentrations between target and circum areas (circum comparison for short), and tested its applications by assessing the air pollution in Jing-Jin-Ji, Yangtze River Delta, Pearl River Delta and Cheng-Yu, China during 2015. We found the circum comparison can instantly judge whether a city is a pollution permeation donor or a pollution permeation receptor by a Pollution Permeation Index (PPI). Furthermore, a PPI-related estimated concentration (original concentration plus halved average concentration difference) can be used to identify some overestimations and underestimations. Besides, it can help explain pollution process (e.g., Beijing’s PM2.5 maybe largely promoted by non-local SO2) though not aiming at it. Moreover, it is applicable to any region, easy-to-handle, and able to boost more new analytical methods. These advantages, despite its disadvantages in considering the whole process jointly influenced by complex physical and chemical factors, demonstrate that the PPI based circum comparison can be efficiently used in assessing air pollution by yielding instructive results, without the absolute need for complex operations. PMID:27731344

  11. Electrophotolysis oxidation system for measurement of organic concentration in water

    NASA Technical Reports Server (NTRS)

    Winkler, H. E. (Inventor)

    1981-01-01

    Methods and apparatus for determining organic carbon in aqueous solution are described. The method comprises subjecting the aqueous solution to electrolysis, for generating oxygen from water, and simultaneously to ultraviolet radiation, for oxidation of substantially all organic carbon to carbon dioxide. The carbon dioxide is measured and the value is related to the concentration of organic carbon in the aqueous solution.

  12. An integrated optical sensor for measuring glucose concentration

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Hering, P.; Scully, M. O.

    1992-01-01

    We used an optical sensor combined with a Mach-Zehnder interferometric waveguide and optical fibers to measure slight changes of aqueous sugar concentrations. The merits of this sensor are simplicity, reliability, high sensitivity and continuous monitoring. The technique is based on the fact that the refractive index of sugar solution changes with the concentration of sugar. In the experiment, one arm of the interferometer is clad with glue and is thus isolated from the sugar solution. The other one is exposed to the sugar solution. A single mode fiber is directly glued onto the interferometric waveguide, to guide the light into the interferometer. If the concentration of sugar covering the waveguide changes, the phase of propagating light in the exposed arm will be changed, while the phase in the other arm is fixed. Hence the output intensity from the interferometer is directly related to the concentration of the sugar solution. The result of this experiment yields the relation between the sugar concentration and output signal. From 0% to 1% concentration of sugar solution, there is only a 1.4×10-3 refractive index difference. Two sets of experimental data have been obtained, showing a linear relation between the sugar concentration and the output signal from our sensor. This sensor could be used for continuous monitoring of blood sugar in the human body.

  13. Persistence analysis of extreme CO, NO2 and O3 concentrations in ambient air of Delhi

    NASA Astrophysics Data System (ADS)

    Chelani, Asha B.

    2012-05-01

    Persistence analysis of air pollutant concentration and corresponding exceedance time series is carried out to examine for temporal evolution. For this purpose, air pollutant concentrations, namely, CO, NO2 and O3 observed during 2000-2009 at a traffic site in Delhi are analyzed using detrended fluctuation analysis. Two types of extreme values are analyzed; exceeded concentrations to a threshold provided by national pollution controlling agency and time interval between two exceedances. The time series of three pollutants is observed to possess persistence property whereas the extreme value time series of only primary pollutant concentrations is found to be persistent. Two time scaling regions are observed to be significant in extreme time series of CO and NO2, mainly attributed to implementation of CNG in vehicles. The presence of persistence in three pollutant concentration time series is linked to the property of self-organized criticality. The observed persistence in the time interval between two exceeded levels is a matter of concern as persistent high concentrations can trigger health problems.

  14. Evaluation of passive air sampler calibrations: Selection of sampling rates and implications for the measurement of persistent organic pollutants in air

    NASA Astrophysics Data System (ADS)

    Melymuk, Lisa; Robson, Matthew; Helm, Paul A.; Diamond, Miriam L.

    2011-04-01

    Polyurethane foam (PUF) passive air samplers (PAS) are a common and highly useful method of sampling persistent organic pollutants (POP) concentrations in air. PAS calibration is necessary to obtain reasonable and comparable semi-quantitative measures of air concentrations. Various methods are found in the literature concerning PAS calibration. 35 studies on PAS use and calibration are examined here, in conjunction with a study involving 10 PAS deployed concurrently in outdoor air with a low-volume air sampler in order to measure the sampling rates of PUF-PAS for polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), polycyclic musks (PCMs), and polycyclic aromatic hydrocarbons (PAHs). Based on this analysis it is recommended that (1) PAS should be assumed to represent bulk rather than gas-phase compound concentrations due to the sampling of particle-bound compounds, (2) calibration of PAS sampling rates is more accurately achieved using an active low-volume air sampler rather than depuration compounds since the former measures gas- and particle-phase compounds and does so continuously over the deployment period of the PAS, and (3) homolog-specific sampling rates based on KOA groupings be used in preference to compound/congener-specific or single sampling rates.

  15. Practical considerations for measuring hydrogen concentrations in groundwater

    USGS Publications Warehouse

    Chapelle, F.H.; Vroblesky, D.A.; Woodward, J.C.; Lovley, D.R.

    1997-01-01

    Several practical considerations for measuring concentrations of dissolved molecular hydrogen (H2) in groundwater including 1 sampling methods 2 pumping methods and (3) effects of well casing materials were evaluated. Three different sampling methodologies (a downhole sampler, a gas- stripping method, and a diffusion sampler) were compared. The downhole sampler and gas-stripping methods gave similar results when applied to the same wells, the other hand, appeared to The diffusion sampler, on overestimate H2 concentrations relative to the downhole sampler. Of these methods, the gas-stripping method is better suited to field conditions because it is faster (~ 30 min for a single analysis as opposed to 2 h for the downhole sampler or 8 h for the diffusion sampler), the analysis is easier (less sample manipulation is required), and the data computations are more straightforward (H2 concentrations need not be corrected for water sample volume). Measurement of H2 using the gas-stripping method can be affected by different pumping equipment. Peristaltic, piston, and bladder pumps all gave similar results when applied to water produced from the same well. It was observed, however, that peristaltic-pumped water (which draws water under a negative pressure) enhanced the gas-stripping process and equilibrated slightly faster than either piston or bladder pumps (which push water under a positive pressure). A direct current(dc) electrically driven submersible pump was observed to produce H2 and was not suitable for measuring H2 in groundwater. Measurements from two field sites indicate that iron or steel well casings, produce H2, which masks H2 concentrations in groundwater. PVC-cased wells or wells cased with other materials that do not produce H2 are necessary for measuring H2 concentrations in groundwater.Several practical considerations for measuring concentrations of dissolved molecular hydrogen in groundwater including sampling methods, pumping methods, and effects of

  16. Airborne particle concentrations at schools measured at different spatial scales

    NASA Astrophysics Data System (ADS)

    Buonanno, G.; Fuoco, F. C.; Morawska, L.; Stabile, L.

    2013-03-01

    Potential adverse effects on children health may result from school exposure to airborne particles. To address this issue, measurements in terms of particle number concentration, particle size distribution and black carbon (BC) concentrations were performed in three school buildings in Cassino (Italy) and its suburbs, outside and inside of the classrooms during normal occupancy and use. Additional time resolved information was gathered on ventilation condition, classroom activity, and traffic count data around the schools were obtained using a video camera. Across the three investigated school buildings, the outdoor and indoor particle number concentration monitored down to 4 nm and up to 3 μm ranged from 2.8 × 104 part cm-3 to 4.7 × 104 part cm-3 and from 2.0 × 104 part cm-3 to 3.5 × 104 part cm-3, respectively. The total particle concentrations were usually higher outdoors than indoors, because no indoor sources were detected. I/O measured was less than 1 (varying in a relatively narrow range from 0.63 to 0.74), however one school exhibited indoor concentrations higher than outdoor during the morning rush hours. Particle size distribution at the outdoor site showed high particle concentrations in different size ranges, varying during the day; in relation to the starting and finishing of school time two modes were found. BC concentrations were 5 times higher at the urban school compared with the suburban and suburban-to-urban differences were larger than the relative differences of ultrafine particle concentrations.

  17. In Situ Measurements of Aerosol Mass Concentration and Spectral Absorption in Xianghe, SE of Beijing, China

    NASA Astrophysics Data System (ADS)

    Chaudhry, Z.; Martins, V.; Li, Z.

    2005-12-01

    China's rapid industrialization over the last few decades has affected air quality in many regions of China, and even the regional climate. As a part of the EAST-AIRE (East Asian Study of Tropospheric Aerosols: an International Regional Experiment) study, Nuclepore filters were collected in two size ranges (PM10 and PM2.5) at 12 hour intervals since January 2005 at Xianghe, about 70 km southeast of Beijing. Each filter was analyzed for mass concentration, aerosol scattering and absorption efficiencies. Mass concentrations during the winter months (January-March) ranged from 9 to 459 μg/m3 in the coarse mode with an average concentration of 122 μg/m3, and from 11 to 203 μg/m3 in the fine mode with an average concentration of 45 μg/m3. While some of the extreme values are likely linked to local emissions, regional air pollution episodes also played important roles. Absorption efficiency measurements at 550 nm show very high values compared to measurements performed in the United States during the CLAMS experiment. The spectral mass absorption efficiency was measured from 350 to 2500 nm and shows large differences between the absorption properties of soil dust, black carbon, and organic aerosols. The strong spectral differences observed can be related to differences in refractive indices from the several collected species and particle size effects. The absorption properties from aerosols measured in China show large absorption efficiencies, compared to aerosols measured in the US, possibly linked to different technology practices used in these countries. For organic plus black carbon aerosols, where the refractive index seems to be relatively constant, the absorption efficiency spectral dependence for fine mode aerosols falls between 1/λ and 1/λ2. The coarse mode absorption shows much less spectral dependence.

  18. Influence of temperature changes on ambient air NOx chemiluminescence measurements.

    PubMed

    Miñarro, Marta Doval; Ferradás, Enrique González; Martínez, Francisco J Marzal

    2012-09-01

    Users of automatic air pollution monitors are largely unaware of how certain parameters, like temperature, can affect readings. The present work examines the influence of temperature changes on chemiluminescence NO(x) measurements made with a Thermo Scientific 42i analyzer, a model widely used in air monitoring networks and air pollution studies. These changes are grouped into two categories according to European Standard EN 14211: (1) changes in the air surrounding the analyzers and (2) changes in the sampled air. First, the sensitivity tests described in Standard EN 14211 were performed to determine whether the analyzer performance was adapted to the requirements of the standard. The analyzer met the performance criteria of both tests; however, some differences were detected in readings with temperature changes even though the temperature compensator was on. Sample temperature changes were studied more deeply as they were the most critical (they cannot be controlled and differences of several tens of degrees can be present in a single day). Significant differences in readings were obtained when changing sample temperature; however, maximum deviations were around 3% for temperature ranges of 15°C. If other possible uncertainty contributions are controlled and temperature variations with respect to the calibration temperature are not higher than 15°C, the effect of temperature changes could be acceptable and no data correction should have to be applied. PMID:21964932

  19. A Tale of Two Cities - HSI-DOAS Measurements of Air Quality

    NASA Astrophysics Data System (ADS)

    Graves, Rosemarie; Leigh, Roland; Anand, Jasdeep; McNally, Michael; Lawrence, James; Monks, Paul

    2013-04-01

    Differential Optical Absorption Spectroscopy is now commonly used as an air quality measuring system; primarily through the measurements of nitrogen dioxide (NO2) both as a ground-based and satellite technique. CityScan is a Hemispherical Scanning Imaging Differential Optical Absorption Spectrometer (HSI-DOAS) which has been optimised to measure concentrations of nitrogen dioxide. CityScan has a 95˚ field of view (FOV) between the zenith and 5˚ below the horizon. Across this FOV there are 128 resolved elements which are measured concurrently, the spectrometer is rotated azimuthally 1˚ per second providing full hemispherical coverage every 6 minutes. CityScan measures concentrations of nitrogen dioxide over specific lines of sight and due to the extensive field of view of the instrument this produces measurements which are representative over city-wide scales. Nitrogen dioxide is an important air pollutant which is produced in all combustion processes and can reduce lung function; especially in sensitised individuals. These instruments aim to bridge the gap in spatial scales between point source measurements of air quality and satellite measurements of air quality offering additional information on emissions, transport and the chemistry of nitrogen dioxide. More information regarding the CityScan technique can be found at http://www.leos.le.ac.uk/aq/index.html. CityScan has been deployed in both London and Bologna, Italy during 2012. The London deployment took place as part of the large NERC funded ClearfLo project in January and July/August. CityScan was deployed in Bologna in June as part of the large EU project PEGASOS. Analysis of both of these campaigns of data will be used to give unprecedented levels of spatial information to air quality measurements whilst also showing the difference in air quality between a relatively isolated mega city and a smaller city situated in a very polluted region; in this case the Po Valley. Results from multiple City

  20. Measurement of acidic aerosol species in eastern Europe: implications for air pollution epidemiology.

    PubMed Central

    Brauer, M; Dumyahn, T S; Spengler, J D; Gutschmidt, K; Heinrich, J; Wichmann, H E

    1995-01-01

    A large number of studies have indicated associations between particulate air pollution and adverse health outcomes. Wintertime air pollution in particular has been associated with increased mortality. Identification of causal constituents of inhalable particulate matter has been elusive, although one candidate has been the acidity of the aerosol. Here we report measurements of acidic aerosol species made for approximately 1.5 years in Erfurt, Germany, and Sokolov, Czech Republic. In both locations, the burning of high-sulfur coal is the primary source of ambient air pollution. Twenty-four-hour average measurements were made for PM10, [particulate matter with an aerodynamic diameter (da) < or = 10 microns], as well as fine particle (da < 2.5 microns) H+ and SO4(2-) for the entire study. Additionally, separate day and night measurements of fine particle H+, SO4(2-), NO3-, and NH4+ and the gases, SO2, HNO3, HONO, and NH3 were collected with an annular denuder/filter pack system over a 7-month (late winter-summer) period with additional measurements during pollution episodes the following winter. At both sites, 24-hr SO2 (mean concentrations of 52 micrograms/m3, with peak levels of > 585 micrograms/m3) and PM10 (mean concentration 60 micrograms m3) concentrations were quite high. However, aerosol SO4(2-) concentrations (mean concentration of approximately 10 micrograms/m3) were not as great as expected given the high SO2 concentrations, and acidity was very low (mean concentration of < 1 microgram/m3, with peak levels of only 7 micrograms/m3). Low acidity is likely to be the result of NH3 neutralization and slow conversion of SO2 to SO4(2-).(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7656878

  1. Contribution of ship emissions to the concentration and deposition of air pollutants in Europe

    NASA Astrophysics Data System (ADS)

    Aksoyoglu, S.; Prévôt, A. S. H.; Baltensperger, U.

    2015-11-01

    Emissions from the marine transport sector are one of the least regulated anthropogenic emission sources and contribute significantly to air pollution. Although strict limits were introduced recently for the maximum sulfur content in marine fuels in the SECAs (sulfur emission control areas) and in the EU ports, sulfur emissions outside the SECAs and emissions of other components in all European maritime areas have continued to increase in the last two decades. We have used the air quality model CAMx with and without ship emissions for the year 2006 to determine the effects of international shipping on the annual as well as seasonal concentrations of ozone, primary and secondary components of PM2.5 and the dry and wet deposition of nitrogen and sulfur compounds in Europe. Our results suggest that emissions from international shipping affect the air quality in northern and southern Europe differently and their contributions to the air concentrations vary seasonally. The largest changes in pollutant concentrations due to ship emissions were predicted for summer. Increased concentrations of the primary particle mass were found only along the shipping routes whereas concentrations of the secondary pollutants were affected over a larger area. Concentrations of particulate sulfate increased due to ship emissions in the Mediterranean (up to 60 %), in the English Channel and the North Sea (30-35 %) while increases in particulate nitrate levels were found especially in the north, around the Benelux area (20 %) where there were high NH3 land-based emissions. Our model results showed that not only the atmospheric concentrations of pollutants are affected by ship emissions, but also depositions of nitrogen and sulfur compounds increase significantly along the shipping routes. NOx emissions from the ships especially in the English Channel and the North Sea, cause a decrease in the dry deposition of reduced nitrogen at source regions by moving it from the gas-phase to the

  2. The association of particulate air metal concentrations with heart rate variability.

    PubMed Central

    Magari, Shannon R; Schwartz, Joel; Williams, Paige L; Hauser, Russ; Smith, Thomas J; Christiani, David C

    2002-01-01

    Numerous studies show an association between particulate air pollution and adverse health effects. Particulate matter is a complex mixture of elemental carbon, ammonium, sulfates, nitrates, organic components, and metals. The mechanisms of action of particulate matter less than or equal to 2.5 micro m in mean aerodynamic diameter (PM(2.5)), as well as the constituents responsible for the observed cardiopulmonary health effects, have not been identified. In this study we focused on the association between the metallic component of PM(2.5) and cardiac autonomic function based on standard heart rate variability (HRV) measures in an epidemiologic study of boilermakers. Thirty-nine male boilermakers were monitored throughout a work shift. Each subject wore an ambulatory electrocardiogram (Holter) monitor and a personal monitor to measure PM(2.5). We used mixed-effects models to regress heart rate and SDNN index (standard deviation of the normal-to-normal) on PM(2.5) and six metals (vanadium, nickel, chromium, lead, copper, and manganese). There were statistically significant mean increases in the SDNN index of 11.30 msec and 3.98 msec for every 1 micro g/m(3) increase in the lead and vanadium concentrations, respectively, after adjusting for mean heart rate, age, and smoking status. Small changes in mean heart rate were seen with all exposure metrics. The results of this study suggest an association between exposure to airborne metals and significant alterations in cardiac autonomic function. These results extend our understanding of the adverse health effects of the metals component of ambient PM(2.5). PMID:12204821

  3. Mexico City air quality research initiative. Volume IV. Characterization and measurement

    SciTech Connect

    Mauzy, A.

    1994-04-01

    This volume describes the methods and the data gathered in an attempt to measure and characterize the meteorological factors and the concentration of different pollutants in the Mexico City Metropolitan Area. The main objective of this document was to provide input for the simulation models and to obtain information that could be used to test and improve the models` performance. Four field campaigns were conducted, as well as routine monitoring, in order to obtain a database of atmospheric dynamics and air pollution characteristics. Sections include Airborne measurements, Remote sensing measurements, and Traditional (in situ) measurements.

  4. Techniques of low technology sampling of air pollution by metals: a comparison of concentrations and map patterns.

    PubMed

    Lloyd, O L; Gailey, F A

    1987-07-01

    During a 17 month survey of air pollution in the town of Armadale, central Scotland, the concentrations of some metals (iron, manganese, zinc, lead, copper, chrome, nickel, cadmium, and cobalt) were measured in seven types of low technology sampler--four indigenous and three transplanted--at 47 sites. The geographical patterns of the concentrations in the samplers were compared on two types of map. For most metals, sites with high concentrations were present close to the foundry and also in the north of the town. The differences between the patterns of pollution shown by the various types of sampler probably reflected differing mechanisms for collection and different affinities for various sizes and types of metal particle.

  5. A concentration rebound method for measuring particle penetrationand deposition in the indoor environment

    SciTech Connect

    tlthatcher@lbl.gov

    2002-09-01

    Continuous, size resolved particle measurements were performed in two houses in order to determine size-dependent particle penetration and deposition in the indoor environment. The experiments consisted of three parts: (1) measurement of the particle loss rate following artificial elevation of indoor particle concentrations, (2) rapid reduction in particle concentration through induced ventilation by pressurization of the houses with HEPA-filtered air, and (3) measurement of the particle concentration rebound after house pressurization stopped. During the particle concentration decay period, when indoor concentrations are very high, losses due to deposition are large compared to gains due to particle infiltration. During the concentration rebound period, the opposite is true. The large variation in indoor concentration allows the effects of penetration and deposition losses to be separated by the transient, two-parameter model we employed to analyze the data. We found penetration factors between 0.3 and 1 and deposition loss rates between 0.1 and 5 h{sup -1}, for particles between 0.1 and 10 {micro}m.

  6. MODELING AIR TOXICS AND PM 2.5 CONCENTRATION FIELDS AS A MEANS FOR FACILITATING HUMAN EXPOSURE ASSESSMENTS

    EPA Science Inventory

    The capability of the US EPA Models-3/Community Multiscale Air Quality (CMAQ) modeling system is extended to provide gridded ambient air quality concentration fields at fine scales. These fields will drive human exposure to air toxics and fine particulate matter (PM2.5) models...

  7. Coherent anti-Stokes Raman spectroscopic measurement of air entrainment in argon plasma jets

    SciTech Connect

    Fincke, J.R.; Rodriquez, R.; Pentecost, C.G.

    1990-01-01

    The concentration and temperature of air entrained into an argon plasma jet has been measured using coherent anti-Stokes Raman spectroscopy (CARS). The flow field is characterized by a short region of well behaved laminar flow near the nozzle exit followed by an abrupt transition to turbulence. Once the transition to turbulence occurs, air is rapidly entrained into the jet core. The location of the transition region is thought to be driven by the rapid cooling of the jet and the resulting increase in Reynolds number. 8 refs., 6 figs.

  8. Coherent anti-Stokes Raman spectroscopic measurement of air entrainment in argon plasma jets

    NASA Astrophysics Data System (ADS)

    Fincke, J. R.; Rodriquez, R.; Pentecost, C. G.

    The concentration and temperature of air entrained into an argon plasma jet has been measured using coherent anti-Stokes Raman spectroscopy (CARS). The flow field is characterized by a short region of well behaved laminar flow near the nozzle exit followed by an abrupt transition to turbulence. Once the transition to turbulence occurs, air is rapidly entrained into the jet core. The location of the transition region is thought to be driven by the rapid cooling of the jet and the resulting increase in Reynolds number.

  9. Vertical Tracer Concentration Profiles Measured During the Joint Urban 2003 Dispersion Study

    SciTech Connect

    Flaherty, Julia E.; Lamb, Brian K.; Allwine, K Jerry; Allwine, Eugene J.

    2007-12-01

    An atmospheric tracer dispersion study known as Joint Urban 2003 was conducted in Oklahoma City, Oklahoma during the summer of 2003. As part of this field program, vertical concentration profiles were measured at approximately 1 km from downtown tracer gas release locations. These profiles indicated that the urban landscape was very effective in mixing the plume vertically. The height of the plume centerline (as determined by the maximum concentration over the depth of the measurements) for any specific 30 min period varied over the 65 m measurement range. Most of the variations in tracer concentration observed in the profile time series were related to changes in wind direction as opposed to changes in turbulence. As a simple analysis tool for emergency response, maximum normalized concentration curves were developed with 5-minute averaged measurements. These curves give the maximum concentration (normalized by the release rate) that would be observed as a function of downwind distance in an urban area. The 5-min data resulted in greater concentrations than predicted with a simple Gaussian plume model. However, the curve compared well with results from a computational fluid dynamics simulation. This dispersion dataset is a valuable asset not only for refining air quality models, but also for developing new tools for emergency response personnel in the event of a toxic release.

  10. Estimates of CO2 traffic emissions from mobile concentration measurements

    NASA Astrophysics Data System (ADS)

    Maness, H. L.; Thurlow, M. E.; McDonald, B. C.; Harley, R. A.

    2015-03-01

    We present data from a new mobile system intended to aid in the design of upcoming urban CO2-monitoring networks. Our collected data include GPS probe data, video-derived traffic density, and accurate CO2 concentration measurements. The method described here is economical, scalable, and self-contained, allowing for potential future deployment in locations without existing traffic infrastructure or vehicle fleet information. Using a test data set collected on California Highway 24 over a 2 week period, we observe that on-road CO2 concentrations are elevated by a factor of 2 in congestion compared to free-flow conditions. This result is found to be consistent with a model including vehicle-induced turbulence and standard engine physics. In contrast to surface concentrations, surface emissions are found to be relatively insensitive to congestion. We next use our model for CO2 concentration together with our data to independently derive vehicle emission rate parameters. Parameters scaling the leading four emission rate terms are found to be within 25% of those expected for a typical passenger car fleet, enabling us to derive instantaneous emission rates directly from our data that compare generally favorably to predictive models presented in the literature. The present results highlight the importance of high spatial and temporal resolution traffic data for interpreting on- and near-road concentration measurements. Future work will focus on transport and the integration of mobile platforms into existing stationary network designs.

  11. Boron concentration measurement in biological tissues by charged particle spectrometry.

    PubMed

    Bortolussi, S; Altieri, S

    2013-11-01

    Measurement of boron concentration in biological tissues is a fundamental aspect of boron neutron capture therapy, because the outcome of the therapy depends on the distribution of boron at a cellular level, besides on its overall concentration. This work describes a measurement technique based on the spectroscopy of the charged particles emitted in the reaction (10)B(n,α)(7)Li induced by thermal neutrons, allowing for a quantitative determination of the boron concentration in the different components that may be simultaneously present in a tissue sample, such as healthy cells, tumor cells and necrotic cells. Thin sections of tissue containing (10)B are cut at low temperatures and irradiated under vacuum in a thermal neutron field. The charged particles arising from the sample during the irradiation are collected by a thin silicon detector, and their spectrum is used to determine boron concentration through relatively easy calculations. The advantages and disadvantages of this technique are here described, and validation of the method using tissue standards with known boron concentrations is presented.

  12. Particle Concentrations and Effectiveness of Free-Standing Air Filters in Bedrooms of Children with Asthma in Detroit, Michigan

    PubMed Central

    Du, Liuliu; Batterman, Stuart; Parker, Edith; Godwin, Christopher; Chin, Jo-Yu; O'Toole, Ashley; Robins, Thomas; Brakefield-Caldwell, Wilma; Lewis, Toby

    2011-01-01

    Asthma can be exacerbated by environmental factors including airborne particulate matter (PM) and environmental tobacco smoke (ETS). We report on a study designed to characterize PM levels and the effectiveness of filters on pollutant exposures of children with asthma. 126 households with an asthmatic child in Detroit, Michigan, were recruited and randomized into control or treatment groups. Both groups received asthma education; the latter also received a free-standing high efficiency air filter placed in the child’s bedroom. Information regarding the home, emission sources, and occupant activities was obtained using surveys administered to the child's caregiver and a household inspection. Over a one-week period, we measured PM, carbon dioxide (CO2), environmental tobacco smoke (ETS) tracers, and air exchange rates (AERs). Filters were installed at midweek. Before filter installation, PM concentrations averaged 28 µg m−3, number concentrations averaged 70,777 and 1,471 L−1 in 0.3–1.0 and 1–5 µm size ranges, respectively, and the median CO2 concentration was 1,018 ppm. ETS tracers were detected in 23 of 38 homes where smoking was unrestricted and occupants included smokers and, when detected, PM concentrations were elevated by an average of 15 µg m−3. Filter use reduced PM concentrations by an average of 69 to 80%. Simulation models representing location conditions show that filter air flow, room volume and AERs are the key parameters affecting PM removal, however, filters can achieve substantial removal in even "worst" case applications. While PM levels in homes with asthmatic children can be high, levels can be dramatically reduced using filters. PMID:21874085

  13. A focused air-pulse system for optical-coherence-tomography-based measurements of tissue elasticity

    NASA Astrophysics Data System (ADS)

    Wang, Shang; Larin, K. V.; Li, Jiasong; Vantipalli, S.; Manapuram, R. K.; Aglyamov, S.; Emelianov, S.; Twa, M. D.

    2013-07-01

    Accurate non-invasive assessment of tissue elasticity in vivo is required for early diagnostics of many tissue abnormalities. We have developed a focused air-pulse system that produces a low-pressure and short-duration air stream, which can be used to excite transient surface waves (SWs) in soft tissues. System characteristics were studied using a high-resolution analog pressure transducer to describe the excitation pressure. Results indicate that the excitation pressure provided by the air-pulse system can be easily controlled by the air source pressure, the angle of delivery, and the distance between the tissue surface and the port of the air-pulse system. Furthermore, we integrated this focused air-pulse system with phase-sensitive optical coherence tomography (PhS-OCT) to make non-contact measurements of tissue elasticity. The PhS-OCT system is used to assess the group velocity of SW propagation, which can be used to determine Young’s modulus. Pilot experiments were performed on gelatin phantoms with different concentrations (10%, 12% and 14% w/w). The results demonstrate the feasibility of using this focused air-pulse system combined with PhS-OCT to estimate tissue elasticity. This easily controlled non-contact technique is potentially useful to study the biomechanical properties of ocular and other tissues in vivo.

  14. Highly integrated optical microsystem for particle concentration measurement

    NASA Astrophysics Data System (ADS)

    Hofmann, Meike; Ma, Xuan; Schneider, Jan; Sinzinger, Stefan

    2010-05-01

    We present our research on integrated optical Talbot interferometers for particle mass concentration measurements. For optimum integration of highly sensitive optical measurement systems we apply a planar emitter-receiver-unit with a vertical cavity surface emitting laser (VCSEL) at 850 nm as light source. The optical system is integrated into a planar transparent PMMA (polymethylmethacrylate) substrate. We suggest a planar integrated free-space optical system for monitoring the particle mass concentration of polydisperse suspensions. Thorough simulations of the optical sensor show that for the required regime of particle concentration and particle size distribution (PSD) turbidity measurements where the attenuation of a light beam is evaluated for example at different wavelengths do not provide the required measurement precision. We therefore propose a system where the probe beam even though sent through the system is blocked before reaching the detector by an interferometric setup. The stray light originating from the particles is exploited for the measurement. For our application we focus on particles with sizes in the range 1 - 120 μm and particle mass concentrations in the range of 1-10 mg/L. In this case significant strength of the scattering signal only appears in small angles relative to the incident probe beam (forward scattering). The probe beam and the stray light thus overlap to a large extent. Our sensor concept is based on a monolithically integrated Talbot interferometer. Two properly aligned diffraction gratings are used to remove the primary beam. We use a stripe detector as second grating. The stray light causes perturbations within the formation of the self image of the grating. These perturbations are visualized as speckles on a detector and exploited for particle concentration measurements. The potential of the sensor concept is presented on the example of a modular Talbot interferometer using a HeNe laser at 633 nm to measure particle mass

  15. Ultrasonic spectrum for particle concentration measurement in multicomponent suspensions

    NASA Astrophysics Data System (ADS)

    Zhan, Xiaobin; Jiang, Shulan; Yang, Yili; Liang, Jian; Shi, Tielin; Li, Xiwen

    2016-02-01

    This paper studies the feasibility of applying the ultrasonic spectrum technique to the measurement of particle concentrations in multicomponent suspensions. A combination of the kernel partial least squares (KPLS) model and the interval selection methods is implemented to build the relationship between the ultrasonic spectra of the first reflected pulses and the particle concentrations. First of all, the interval selection methods are used to select optimal spectral interval(s) from full spectra. Then, the KPLS models with optimal spectral interval(s) are tuned, built and evaluated to obtain the optimal model. Finally, the optimal KPLS model is employed to measure the particle concentrations in the mixing process and its online prediction ability is evaluated. In comparison with the linear partial least squares (PLS) models, the optimal KPLS model shows the best performance. The results demonstrate that particle concentrations in multicomponent suspensions can be measured online by the ultrasonic spectrum technique, and the KPLS model with optimal spectral interval(s) shows the superiority in model calibration.

  16. Determination of methyl radical concentrations in a methane/air flame by infrared cavity ringdown laser absorption spectroscopy

    SciTech Connect

    Scherer, J.J.; Aniolek, K.W.; Cernansky, N.P.; Rakestraw, D.J.

    1997-10-01

    Infrared cavity ringdown laser absorption spectroscopy (IR-CRLAS) is employed to determine absolute methyl radical concentrations in a 37.5 Torr laminar methane/air flame. IR-CRLAS rovibrational absorption spectra of the {nu}{sub 3} fundamental band system near 3200thinspcm{sup {minus}1} are combined with N{sub 2}-CARS temperature measurements to obtain methyl radical concentrations as a function of height above the burner surface. These data are compared with flame chemistry simulations under both stoichiometric and rich flame conditions. Issues regarding the applicability of IR-CRLAS for combustion studies are discussed, including the uncertainties present for the specific case of methyl radical. These IR-CRLAS measurements indicate the ability to monitor reactants, intermediates, and products within a narrow spectral window, and, to our knowledge, constitute the first infrared detection of a polyatomic radical in a flame. {copyright} {ital 1997 American Institute of Physics.}

  17. Concentration and risk assessment of phthalates present in indoor air from newly decorated apartments

    NASA Astrophysics Data System (ADS)

    Pei, X. Q.; Song, M.; Guo, M.; Mo, F. F.; Shen, X. Y.

    2013-04-01

    Phthalate esters (PAEs) are ubiquitous in the indoor environment, owing to their use in consumer products. People spend a considerable amount of time indoors. As a result, human exposure to indoor contaminants is of great concern. People are exposed to phthalates through inhalation and dermal absorption of indoor air. In this study, the concentrations, characteristics and carcinogenic risks of gas-phase and particle-phase phthalates in indoor air from bedroom, living room and study room of 10 newly decorated apartments in Hangzhou, China were first investigated. The mean concentration of phthalates (gas-phase and particle-phase) present in household air was 12 096.4 ng m-3, of which diethyl phthalate (DEP), butylbenzyl phthalate (BBP) and di(2-ethylhexyl) phthalate (DEHP) were the most abundant compounds with concentrations of 2290 ng m-3, 3975 ng m-3 and 2437 ng m-3, respectively, totally accounting for 72.0% of ∑6PAEs. Contamination levels of phthalates varied in different compartments. The concentration of phthalates was the highest 17 363.7 ng m-3 in living room, followed with 11 389.5 ng m-3 in study room, and the lowest 9739.1 ng m-3 in bedroom. It was also found that phthalates mainly accumulated in gaseous form in household air. DEHP posed the greatest health risk to children aged 1-2. Carcinogenic risk of DEHP was evaluated to be 3.912 × 10-5, and was 39 times higher than the limit set by the U.S. EPA.

  18. A pilot study to assess ground-level ambient air concentrations of fine particles and carbon monoxide in urban Guatemala.

    PubMed

    Shendell, Derek G; Naeher, Luke P

    2002-11-01

    Ambient concentrations and the elemental composition of particles less than 2.5 microm in diameter (PM2.5), as well as carbon monoxide (CO) concentrations, were measured at ground-level in three Guatemalan cities in summer 1997: Guatemala City, Quetzaltenango, and Antigua. This pilot study also included quantitative and qualitative characterizations of microenvironment conditions, e.g., local meteorology, reported elsewhere. The nondestructive X-ray fluorescence elemental analysis (XRF) of Teflon filters was conducted. The highest integrated average PM2.5. concentrations in an area (zona) of Guatemala City and Quetzaltenango were 150 microg m(-3) (zona 12) and 120 microg m(-3) (zona 2), respectively. The reported integrated average PM2.5 concentration for Antigua was 5 microg m(-3). The highest observed half-hour and monitoring period average CO concentrations in Guatemala City were 10.9 ppm (zona 8) and 7.2 ppm (zonas 8 and 10), respectively. The average monitoring period CO concentration in Antigua was 2.6 ppm. Lead and bromine concentrations were negligible, indicative of the transition to unleaded fuel use in cars and motorcycles. The XRF results suggested sources of air pollution in Guatemala, where relative rankings varied by city and by zonas within each city, were fossil fuel combustion emitting hydrocarbons, combustion of sulfurous conventional fuels, soil/roadway dust, farm/agricultural dust, and vehicles (evaportion of gas, parts' wear).

  19. Continuous measurements of ammonia, nitrous oxide and methane from air scrubbers at pig housing facilities.

    PubMed

    Van der Heyden, C; Brusselman, E; Volcke, E I P; Demeyer, P

    2016-10-01

    Ammonia, largely emitted by agriculture, involves a great risk for eutrophication and acidification leading to biodiversity loss. Air scrubbers are widely applied to reduce ammonia emission from pig and poultry housing facilities, but it is not always clear whether their performance meets the requirements. Besides, there is a growing international concern for the livestock related greenhouse gases methane and nitrous oxide but hardly any data concerning their fate in air scrubbers are available. This contribution presents the results from measurement campaigns conducted at a chemical, a biological and a two-stage biological air scrubber installed at pig housing facilities in Flanders. Ammonia, nitrous oxide and methane at the inlet and outlet of the air scrubbers were monitored on-line during one week using a photoacoustic gas monitor, which allowed to investigate diurnal fluctuations in the removal performance of air scrubbers. Additionally, the homogeneity of the air scrubbers, normally checked by gas detection tubes, was investigated in more detail using the continuous data. The biological air scrubber with extra nitrification tank performed well in terms of ammonia removal (86 ± 6%), while the two-stage air scrubber suffered from nitrifying bacteria inhibition. In the chemical air scrubber the pH was not kept constant, lowering the ammonia removal efficiency. A lower ammonia removal efficiency was found during the day, when the ventilation rate was the highest. Nitrous oxide was produced inside the biological and two-stage scrubber, resulting in an increased outlet concentration of more than 200%. Methane could not be removed in the different air scrubbers because of its low water solubility. PMID:27341376

  20. Continuous measurements of ammonia, nitrous oxide and methane from air scrubbers at pig housing facilities.

    PubMed

    Van der Heyden, C; Brusselman, E; Volcke, E I P; Demeyer, P

    2016-10-01

    Ammonia, largely emitted by agriculture, involves a great risk for eutrophication and acidification leading to biodiversity loss. Air scrubbers are widely applied to reduce ammonia emission from pig and poultry housing facilities, but it is not always clear whether their performance meets the requirements. Besides, there is a growing international concern for the livestock related greenhouse gases methane and nitrous oxide but hardly any data concerning their fate in air scrubbers are available. This contribution presents the results from measurement campaigns conducted at a chemical, a biological and a two-stage biological air scrubber installed at pig housing facilities in Flanders. Ammonia, nitrous oxide and methane at the inlet and outlet of the air scrubbers were monitored on-line during one week using a photoacoustic gas monitor, which allowed to investigate diurnal fluctuations in the removal performance of air scrubbers. Additionally, the homogeneity of the air scrubbers, normally checked by gas detection tubes, was investigated in more detail using the continuous data. The biological air scrubber with extra nitrification tank performed well in terms of ammonia removal (86 ± 6%), while the two-stage air scrubber suffered from nitrifying bacteria inhibition. In the chemical air scrubber the pH was not kept constant, lowering the ammonia removal efficiency. A lower ammonia removal efficiency was found during the day, when the ventilation rate was the highest. Nitrous oxide was produced inside the biological and two-stage scrubber, resulting in an increased outlet concentration of more than 200%. Methane could not be removed in the different air scrubbers because of its low water solubility.

  1. Quality-assured measurements of animal building emissions: particulate matter concentrations.

    PubMed

    Heber, Albert J; Lim, Teng-Teeh; Ni, Ji-Qin; Tao, Pei-Chun; Schmidt, Amy M; Koziel, Jacek A; Hoff, Steven J; Jacobson, Larry D; Zhang, Yuanhui; Baughman, Gerald B

    2006-12-01

    Federally funded, multistate field studies were initiated in 2002 to measure emissions of particulate matter (PM) < 10 microm (PM10) and total suspended particulate (TSP), ammonia, hydrogen sulfide, carbon dioxide, methane, nonmethane hydrocarbons, and odor from swine and poultry production buildings in the United States. This paper describes the use of a continuous PM analyzer based on the tapered element oscillating microbalance (TEOM). In these studies, the TEOM was used to measure PM emissions at identical locations in paired barns. Measuring PM concentrations in swine and poultry barns, compared with measuring PM in ambient air, required more frequent maintenance of the TEOM. External screens were used to prevent rapid plugging of the insect screen in the PM10 preseparator inlet. Minute means of mass concentrations exhibited a sinusoidal pattern that followed the variation of relative humidity, indicating that mass concentration measurements were affected by water vapor condensation onto and evaporation of moisture from the TEOM filter. Filter loading increased the humidity effect, most likely because of increased water vapor adsorption capacity of added PM. In a single layer barn study, collocated TEOMs, equipped with TSP and PM10 inlets, corresponded well when placed near the inlets of exhaust fans in a layer barn. Initial data showed that average daily mean concentrations of TSP, PM10, and PM2.5 concentrations at a layer barn were 1440 +/- 182 microg/m3 (n = 2), 553 +/- 79 microg/m3 (n = 4), and 33 +/- 75 microg/m3 (n = 1), respectively. The daily mean TSP concentration (n = 1) of a swine barn sprinkled with soybean oil was 67% lower than an untreated swine barn, which had a daily mean TSP concentration of 1143 +/- 619 microg/m3. The daily mean ambient TSP concentration (n = 1) near the swine barns was 25 +/- 8 microg/m3. Concentrations of PM inside the swine barns were correlated to pig activity. PMID:17195483

  2. An assessment of indoor air concentrations and health risks of volatile organic compounds in three primary schools.

    PubMed

    Sofuoglu, Sait C; Aslan, Guler; Inal, Fikret; Sofuoglu, Aysun

    2011-01-01

    Concentrations of volatile organic compounds (VOCs), including formaldehyde, in classrooms, kindergartens, and outdoor playgrounds of three primary schools were measured in spring, winter, and fall terms in İzmir, Turkey. A health-risk assessment was conducted for odor detection, sensory irritation, chronic toxic effects, and cancer. Active sampling was applied for VOCs and formaldehyde on Tenax TA and DNPH tubes, respectively. VOCs were analyzed in a thermal desorption-GC-MS system. Formaldehyde analysis was performed using an HPLC instrument. Benzene, toluene, and formaldehyde were the most abundant compounds with 95th percentile indoor air concentrations of 29, 87, and 106 μg/m(3), respectively. Naphthalene and xylenes followed them with an order of magnitude lower concentrations. Two isomers of dichlorobenzene (1,3 and 1,4) were the other notable compounds. The concentrations were utilized to classify the indoor air pollutants with respect to potential health effects. In addition, carcinogenic and chronic toxic risks were estimated using Monte-Carlo simulation. Formaldehyde appears to be the most concerning pollutant with high chronic toxic and carcinogenic risk levels according to the health assessment followed by naphthalene, benzene, and toluene due to their chronic effects.

  3. Number concentration and size of particles in urban air: effects on spirometric lung function in adult asthmatic subjects.

    PubMed Central

    Penttinen, P; Timonen, K L; Tiittanen, P; Mirme, A; Ruuskanen, J; Pekkanen, J

    2001-01-01

    Daily variations in ambient particulate air pollution are associated with variations in respiratory lung function. It has been suggested that the effects of particulate matter may be due to particles in the ultrafine (0.01-0.1 microm) size range. Because previous studies on ultrafine particles only used self-monitored peak expiratory flow rate (PEFR), we assessed the associations between particle mass and number concentrations in several size ranges measured at a central site and measured (biweekly) spirometric lung function among a group of 54 adult asthmatics (n = 495 measurements). We also compared results to daily morning, afternoon, and evening PEFR measurements done at home (n = 7,672-8,110 measurements). The median (maximum) 24 hr number concentrations were 14,500/cm(3) (46,500/cm(3)) ultrafine particles and 800/cm(3) (2,800/cm(3)) accumulation mode (0.1-1 microm) particles. The median (maximum) mass concentration of PM(2.5) (particulate matter < 2.5 microm) and PM(10) (particulate matter < 10 microm in aerodynamic diameter) were 8.4 microg/m(3) (38.3 microg/m(3)) and 13.5 microg/m(3) (73.7 microg/m(3)), respectively. The number of accumulation mode particles was consistently inversely associated with PEFR in spirometry. Inverse, but nonsignificant, associations were observed with ultrafine particles, and no associations were observed with large particles (PM(10)). Compared to the effect estimates for self-monitored PEFR, the effect estimates for spirometric PEFR tended to be larger. The standard errors were also larger, probably due to the lower number of spirometric measurements. The present results support the need to monitor the particle number and size distributions in urban air in addition to mass. PMID:11335178

  4. Near-infrared open-path measurement of CO₂ concentration in the urban atmosphere.

    PubMed

    Saito, Hayato; Manago, Naohiro; Kuriyama, Kenji; Kuze, Hiroaki

    2015-06-01

    Average concentration of carbon dioxide (CO2) has been measured over a path length of 5.1 km in the lower troposphere by the method of differential optical absorption spectroscopy (DOAS) using a near-infrared light source based on amplified spontaneous emission. The analysis of CO2 absorption intensity around 1575 nm observed during 10 days over the Chiba city area has revealed that the CO2 concentration varied in the range of around 360-450 ppmv, with presumable influence of air mass advection from nearby industrial facilities. In addition, a good correlation has been found in relative humidity values between the DOAS and meteorological station data. As a whole, the present result indicates the usefulness of such a DOAS approach for measuring the concentration of CO2 averaged over an optical path of a few kilometers in the lower troposphere. PMID:26030559

  5. Response of ozone to changes in hydrocarbon and nitrogen oxide concentrations in outdoor smog chambers filled with Los Angeles air

    NASA Astrophysics Data System (ADS)

    Kelly, Nelson A.; Gunst, Richard F.

    During the summer portion of the 1987 Southern California Air Quality Study (SCAQS), outdoor smog chamber experiments were performed on Los Angeles air to determine the response of maximum ozone levels, O 3(max), to changes in the initial concentrations of hydrocarbons, HC, and nitrogen oxides, NO x. These captive-air experiments were conducted in downtown Los Angeles and in the downwind suburb of Claremont. Typically, eight chambers were filled with LA air in the morning. In some chambers the initial HC and/or NO x concentrations were changed by 25% to 50% by adding various combinations of a mixture of HC, clean air, or NO x. The O 3 concentration in each chamber was monitored throughout the day to determine O 3(max). An empirical mathematical model for O 3(max) was developed from regression fits to the initial HC and NO x concentrations and to the average daily temperature at both sites. This is the first time that a mathematical expression for the O 3-precursor relationship and the positive effect of temperature on O 3(max) have been quantified using captive-air experiments. An ozone isopleth diagram prepared from the empirical model was qualitatively similar to those prepared from photochemical mechanisms. This constitutes the first solely empirical corroboration of the O 3 contour shape for Los Angeles. To comply with the Federal Ozone Standard in LA, O 3(max) must be reduced by approximately 50%. Several strategies for reducing O 3(max) by 50% were evaluated using the empirical model. For the average initial conditions that we measured in LA, the most efficient strategy is one that reduces HC by 55-75%, depending on the ambient HC/NO x ratio. Any accompanying reduction in NO x would be counter-productive to the benefits of HC reductions. In fact, reducing HC and NO x simultaneously requires larger percentage reductions for both than the reduction required when HC alone is reduced. The HC-reduction strategy is the most efficient on average, but no single

  6. Development and Evaluation of Land-Use Regression Models Using Modeled Air Quality Concentrations

    EPA Science Inventory

    Abstract Land-use regression (LUR) models have emerged as a preferred methodology for estimating individual exposure to ambient air pollution in epidemiologic studies in absence of subject-specific measurements. Although there is a growing literature focused on LUR evaluation, fu...

  7. 10 CFR Appendix A to Part 835 - Derived Air Concentrations (DAC) for Controlling Radiation Exposure to Workers at DOE Facilities

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Derived Air Concentrations (DAC) for Controlling Radiation... RADIATION PROTECTION Pt. 835, App. A Appendix A to Part 835—Derived Air Concentrations (DAC) for Controlling Radiation Exposure to Workers at DOE Facilities The data presented in appendix A are to be used...

  8. Intra-Fuel Cell Stack Measurements of Transient Concentration Distributions

    SciTech Connect

    Partridge Jr, William P; Toops, Todd J; Green Jr, Johney Boyd; Armstrong, Timothy R.

    2006-01-01

    Intra-fuel-cell measurements are required to understand detailed fuel-cell chemistry and physics, validate models, optimize system design and control, and realize enhanced efficiency regimes; in comparison, conventional integrated fuel-cell supply and effluent measurements are fundamentally limited in value. Intra-reactor measurements are needed for all fuel cell types. This paper demonstrates the ability of a capillary-inlet mass spectrometer to resolve transient species distributions within operating polymer-electrolyte-membrane (PEM) fuel cells and at temperatures typical of solid-oxide fuel cells (SOFC). This is the first such demonstration of a diagnostic that is sufficiently minimally invasive as to allow measurements throughout an operating fuel cell stack. Measurements of transient water, hydrogen, oxygen and diluent concentration dynamics associated with fuel-cell load switching suggest oxygen-limited chemistry. Intra-PEM fuel cell measurements of oxygen distribution at various fuel-cell loads are used to demonstrate concentration gradients, non-uniformities, and anomalous fuel cell operation.

  9. Intra-fuel cell stack measurements of transient concentration distributions

    NASA Astrophysics Data System (ADS)

    Partridge, W. P.; Toops, T. J.; Green, J. B.; Armstrong, T. R.

    Intra-fuel-cell measurements are required to understand detailed fuel-cell chemistry and physics, validate models, optimize system design and control, and realize enhanced efficiency regimes; in comparison, conventional integrated fuel-cell supply and effluent measurements are fundamentally limited in value. Intra-reactor measurements are needed for all fuel cell types. This paper demonstrates the ability of a capillary-inlet mass spectrometer to resolve transient species distributions within operating polymer-electrolyte-membrane (PEM) fuel cells and at temperatures typical of solid-oxide fuel cells (SOFC). This is the first such demonstration of a diagnostic that is sufficiently minimally invasive as to allow measurements throughout an operating fuel cell stack. Measurements of transient water, hydrogen, oxygen and diluent concentration dynamics associated with fuel-cell load switching suggest oxygen-limited chemistry. Intra-PEM fuel cell measurements of oxygen distribution at various fuel-cell loads are used to demonstrate concentration gradients, non-uniformities, and anomalous fuel cell operation.

  10. Methane emission from naturally ventilated livestock buildings can be determined from gas concentration measurements.

    PubMed

    Bjerg, Bjarne; Zhang, Guoqiang; Madsen, Jørgen; Rom, Hans B

    2012-10-01

    Determination of emission of contaminant gases as ammonia, methane, or laughing gas from natural ventilated livestock buildings with large opening is a challenge due to the large variations in gas concentration and air velocity in the openings. The close relation between calculated animal heat production and the carbon dioxide production from the animals have in several cases been utilized for estimation of the ventilation air exchange rate for the estimation of ammonia and greenhouse gas emissions. Using this method, the problem of the complicated air velocity and concentration distribution in the openings is avoided; however, there are still some important issues remained unanswered: (1) the precision of the estimations, (2) the requirement for the length of measuring periods, and (3) the required measuring point number and location. The purpose of this work was to investigate how estimated average gas emission and the precision of the estimation are influenced by different calculation procedures, measuring period length, measure point locations, measure point numbers, and criteria for excluding measuring data. The analyses were based on existing data from a 6-day measuring period in a naturally ventilated, 150 milking cow building. The results showed that the methane emission can be determined with much higher precision than ammonia or laughing gas emissions, and, for methane, relatively precise estimations can be based on measure periods as short as 3 h. This result makes it feasible to investigate the influence of feed composition on methane emission in a relative large number of operating cattle buildings and consequently it can support a development towards reduced greenhouse gas emission from cattle production. PMID:22020391

  11. Advances in Fast Response Acoustically Derived Air Temperature Measurements

    NASA Astrophysics Data System (ADS)

    Bogoev, Ivan; Jacobsen, Larry; Horst, Thomas; Conrad, Benjamin

    2016-04-01

    Fast-response accurate air-temperature measurements are required when estimating turbulent fluxes of heat, water and carbon dioxide by open-path eddy-covariance technique. In comparison with contact thermometers like thermocouples, ultra-sonic thermometers do not suffer from solar radiation loading, water vapor condensation and evaporative cooling effects. Consequently they have the potential to provide more accurate true air temperature measurements. The absolute accuracy of the ultrasonic thermometer is limited by the following parameters: the distance between the transducer pairs, transducer delays associated with the electrical-acoustic signal conversion that vary with temperature, components of the wind vector that are normal to the ultrasonic paths, and humidity. The distance between the transducer pairs is commonly obtained by coordinate measuring machine. Improved accuracy demonstrated in this study results from increased stiffness in the anemometer head to better maintain the ultrasonic path-length distances. To further improve accuracy and account for changes in transducer delays and distance as a function of temperature, these parameters are characterized in a zero-wind chamber over the entire operating temperature range. When the sonic anemometer is combined with a co-located fast-response water vapor analyzer, like in the IRGASON instrument, speed of sound can be compensated for humidity effects on a point-by-point basis resulting in a true fast-response air temperature measurement. Laboratory test results show that when the above steps are implemented in the calibration of the ultrasonic thermometer air-temperature accuracy better than ±0.5 degrees Celsius can be achieved over the entire operating range. The approach is also validated in a field inter-comparison with an aspirated thermistor probe mounted in a radiation shield.

  12. Measuring Density Of Air By Ultraviolet Rayleigh Scattering

    NASA Technical Reports Server (NTRS)

    Mckenzie, Robert L.

    1992-01-01

    Report presents theoretical and experimental studies directed toward development of optoelectronic instrument to measure density of air at altitudes from 50 to 90 km and possibly beyond. Instrument mounted in Space Shuttle orbiter and operated during reentry into atmosphere. Data gathered by instrument needed because density of upper atmosphere highly variable in space and time and this variability affects aerodynamic behavior and trajectory of reentering Shuttle. Variations in density also meteorologically significant.

  13. Measurement and estimated health risks of volatile organic compounds and polychlorinated biphenyls in air at the Hanford Site

    SciTech Connect

    Patton, G.W.; Cooper, A.T.; Blanton, M.L.

    1994-10-01

    A variety of radioactive and nonradioactive chemicals have been released in effluent streams and discharged to waste disposal facilities during the nuclear materials production period at the Hanford Site. Extensive environmental surveillance for radioactive materials has occurred at Hanford; however, only limited information is available on the types and concentrations of organic pollutants potentially present. This report describes work performed to provide the Hanford Site Surface Environmental Surveillance Project with representative air concentration data for volatile organic compounds and polychlorinated biphenyls (PCBs). US Environmental Protection Agency (USEPA) volatile organic compound sampling methods evaluated for Hanford Site use were carbon-based adsorbent traps (TO-2) and Summa air canisters (TO-14). Polychlorinated biphenyls were sampled using USEPA method (TO-4), which uses glass fiber filters and polyurethane foam adsorbent beds to collect the PCBs. This report also presents results for environmental surveillance samples collected for volatile organic compound and PCB analyses from 1990 to 1993. All measured air concentrations of volatile organic compounds and PCBs were well below applicable maximum allowable concentration standards for air contaminants. Because of the lack of ambient air concentration standards, a conservative estimate is provided of the potential human health impacts from exposure to the ambient air concentrations measured on the Hanford Site.

  14. Observation of elevated air pollutant concentrations in a residential neighborhood of Los Angeles California using a mobile platform

    NASA Astrophysics Data System (ADS)

    Hu, Shishan; Paulson, Suzanne E.; Fruin, Scott; Kozawa, Kathleen; Mara, Steve; Winer, Arthur M.

    2012-05-01

    We observed elevated air pollutant concentrations, especially of ultrafine particles (UFP), black carbon (BC) and NO, across the residential neighborhood of the Boyle Heights Community (BH) of Los Angeles, California. Using an electric vehicle mobile platform equipped with fast response instruments, real-time air pollutant concentrations were measured in BH in spring and summer of 2008. Pollutant concentrations varied significantly in the two seasons, on different days, and by time of day, with an overall average UFP concentration in the residential areas of ∼33 000 cm-3. The averaged UFP, BC, and NO concentrations measured on Soto St, a major surface street in BH, were 57 000 cm-3, 5.1 μg m-3, and 67 ppb, respectively. Concentrations of UFP across the residential areas in BH were nearly uniform spatially, in contrast to other areas in the greater metropolitan area of Los Angeles where UFP concentrations exhibit strong gradients downwind of roadways. We attribute this “UFP cloud” to high traffic volumes, including heavy duty diesel trucks on the freeways which surround and traverse BH, and substantial numbers of high-emitting vehicles (HEVs) on the surface streets traversing BH. Additionally, the high density of stop signs and lights and short block lengths, requiring frequent accelerations of vehicles, may contribute. The data also support a role for photochemical production of UFP in the afternoon. UFP concentration peaks (5 s average) of up to 9 million particles cm-3 were also observed immediately behind HEVs when they accelerated from stop lights in the BH neighborhood and areas immediately adjacent. Although encounters with HEV during mornings accounted for only about 6% and 17% of time spent monitoring residential areas and major surface streets, HEV contributed to about 28% and 53% of total ultrafine particles measured on the route, respectively. The observation of elevated pollutant concentrations across the Boyle Heights community highlights

  15. Air infiltration and building tightness measurements in passive solar residences

    SciTech Connect

    Persily, A.K.; Grot, R.A.

    1984-05-01

    The airtightness of about fifty passive solar homes located throughout the United States was studied using low-cost measurement techniques. These homes are part of the DOE-sponsored Class B monitoring program conducted at the Solar Energy Research Institute (SERI) to evaluate the thermal performance of passive solar residential buildings. These tests provide the first set of building tightness measurements on a large group of passive solar buildings. The measurements include pressurization tests to measure airtightness and tracer gas measurements to determine air infiltration rates. The pressure tests show a variation in the airtightness of these homes from 3 to 30 exchanges/hr at 50 Pascal, with a median of 9.5 exchanges/hr. The air infiltration measurements cover a wider range from 0.05 to 3.0 exchanges/hr, with a median of 0.5 exchanges/hr. In comparing the tightness of these homes to other U.S. homes, one finds that these passive solar homes are not significantly tighter than homes built with less of an emphasis on energy use.

  16. Radio Emission in Atmospheric Air Showers Measured by LOPES-30

    SciTech Connect

    Isar, P. G.

    2008-01-24

    When Ultra High Energy Cosmic Rays (UHECR) interact with particles in the Earth's atmosphere, they produce a shower of secondary particles propagating towards the ground. These relativistic particles emit synchrotron radiation in the radio frequency range when passing the Earth's magnetic field. The LOPES (LOFAR Prototype Station) experiment investigates the radio emission from these showers in detail and will pave the way to use this detection technique for large scale applications like in LOFAR (Low Frequency Array) and the Pierre Auger Observatory. The LOPES experiment is co-located and measures in coincidence with the air shower experiment KASCADE-Grande at Forschungszentrum Karlsruhe, Germany. LOPES has an absolute amplitude calibration array of 30 dipole antennas (LOPES-30). After one year of measurements of the single East-West polarization by all 30 antennas, recently, the LOPES-30 set-up was configured to perform dual-polarization measurements. Half of the antennas have been configured for measurements of the North-South polarization. Only by measuring at the same time both, the E-W and N-S polarization components of the radio emission, the geo-synchrotron effect as the dominant emission mechanism in air showers can be verified. The status of the measurements, including the absolute calibration procedure of the dual-polarized antennas as well as analysis of dual-polarized event examples are reported.

  17. Simultaneous species concentration and temperature measurements using laser induced breakdown spectroscopy with direct spectrum matching

    NASA Astrophysics Data System (ADS)

    McGann, Brendan J.

    Laser induced breakdown spectroscopy (LIBS) is used to simultaneously measure hydrocarbon fuel concentration and temperature in high temperature, high speed, compressible, and reacting flows, a regime in which LIBS has not been done previously. Emission spectra from the plasma produced from a focused laser pulse is correlated in the combustion region of a model scramjet operating in supersonic wind tunnel. A 532 nm Nd:YAG laser operating at 10 Hz is used to induce break-down. The emissions are captured during a 10 ns gate time approximately 75 ns after the first arrival of photons at the measurement location in order to minimize the measurement uncertainty in the turbulent, compressible, high-speed, and reacting environment. Three methods of emission detection are used and a new backward scattering direction method is developed that is beneficial in reducing the amount of optical access needed to perform LIBS measurements. Measurements are taken in the model supersonic combustion and the ignition process is shown to be highly dependent on fuel concentration and gas density as well as combustion surface temperature, concentration gradient, and flow field. Direct spectrum matching method is developed and used for quantitative measurements. In addition, a comprehensive database of spectra covering the fuel concentrations and gas densities found in the wind tunnel of Research Cell 19 at Wright Patterson Air Force Base is created which can be used for further work.

  18. Measurements of radon concentrations in the lunar atmosphere

    NASA Technical Reports Server (NTRS)

    Brodzinski, R. L.; Jackson, P. O.; Langford, J. C.

    1977-01-01

    The radon concentrations in the lunar atmosphere were determined by measuring the Po-210 progeny activity in artifacts returned from the moon. Experiments performed on a section of the polished aluminum strut from Surveyor 3 and data obtained from the Apollo 16 Cosmic Ray Detector Experiment Teflon thermal shield are compared with other values of the lunar radon concentration obtained at different times and different locations and by various techniques. Possible sources and release mechanisms compatible with all of the data are discussed. An experimental procedure to determine the relative retention coefficients of various types of material for radon progeny in a simulated lunar environment is described. The results of several experiments are given, and their effect on lunar radon progeny measurements is discussed. An analytical procedure is given for the analysis of a Teflon matrix for trace constituents.

  19. Solids concentration measurements in molten wax by an ultrasonic technique

    SciTech Connect

    Soong, Y.; Gamwo, I.K.; Blackwell, A.G.; Schehl, R.R.; Zarochak, M.F.

    1994-12-31

    The application of the three-phase slurry reactor system to coal liquefaction processing and chemical industries has recently received considerable attention. To design and efficiently operate a three-phase slurry reactor, the degree of dispersion of the solid (catalyst) in the reactor should be understood. The solids distribution within the reactor greatly affects its performance. An ultrasonic technique is under development for measuring solids concentration in a three-phase slurry reactor. Preliminary measurements have been made on slurries consisting of molten paraffin wax, glass beads, and nitrogen bubbles at 189 C. The data show that the velocity and attenuation of the sound are well-defined functions of the solid and gas concentrations in the molten wax.

  20. A New Multifunctional Sensor for Measuring Concentrations of Ternary Solution

    NASA Astrophysics Data System (ADS)

    Wei, Guo; Shida, Katsunori

    This paper presents a multifunctional sensor with novel structure, which is capable of directly sensing temperature and two physical parameters of solutions, namely ultrasonic velocity and conductivity. By combined measurement of these three measurable parameters, the concentrations of various components in a ternary solution can be simultaneously determined. The structure and operation principle of the sensor are described, and a regression algorithm based on natural cubic spline interpolation and the least square method is adopted to estimate the concentrations. The performances of the proposed sensor are experimentally tested by the use of ternary aqueous solution of sodium chloride and sucrose, which is widely involved in food and beverage industries. This sensor could prove valuable as a process control sensor in industry fields.

  1. Measurement of photodynamic therapy drug concentrations in a tissue

    SciTech Connect

    Mourant, J.; Biglo, I.; Johnson, T.

    1996-09-01

    This is the final report of a one-year laboratory-directed research and development project at the Los Alamos National Laboratory (LANL). Photodynamic therapy (PDT) is an experimental treatment modality for cancer in which a photoactive molecule with an affinity for tumors in administered to the patient, then excited by light. Photoactivation creates singlet oxygen consequently killing the tissue. Knowledge of the concentration of the photoactive compound in the tissue is necessary for proper light dosimetry during PDT. Presently, the control of light application is problematic. If too much light is applied, damage to the surrounding tissue will occur. If insufficient light is applied, the targeted tissue volume will remain viable. The ideal implementation of PDT would use a feedback system for light delivery that incorporates the optical properties of the tissue and knowledge of the concentration of the photoactive compound. This project sought to develop a method for measuring photosensitizer concentrations in tissue phantoms that will lead to a noninvasive, endoscopically compatible, in vivo method of measuring PST drug concentrations.

  2. Measuring CaMKII concentration in dendritic spines

    PubMed Central

    Otmakhov, Nikolai; Lisman, John

    2011-01-01

    Here, we present a method for measuring the concentration of endogenous protein in cellular compartments. Importantly, the method is applicable to compartments such as dendritic spines with dimensions often close to the resolution limit of optical microscopy. To our knowledge, a method with such capabilities has not yet been described. The method utilizes overexpression of the protein of interest, which is tagged with fluorescent protein. This is followed by immunostaining of both overexpressed and endogenous proteins. Expression of a volume marker is also required. We applied this method to measure the concentration of Ca/Calmodulin kinase II (CaMKII) in different cellular compartments of hippocampal pyramidal neurons. It was found that the concentrations of CaMKIIα subunits in cell bodies, proximal dendrites, and spines on these dendrites are 71, 46, and 103 μM, respectively. Considering the 3:1 ratio of α to β CaMKII subunits in the hippocampus, the concentrations of total (α + β) CaMKII subunits in these compartments are 94, 61, and 138 μM, respectively. PMID:21985762

  3. Biases in field measurements of ice nuclei concentrations

    NASA Astrophysics Data System (ADS)

    Garimella, S.; Voigtländer, J.; Kulkarni, G.; Stratmann, F.; Cziczo, D. J.

    2015-12-01

    Ice nuclei (IN) play an important role in the climate system by influencing cloud properties, precipitation, and radiative transfer. Despite their importance, there are significant uncertainties in estimating IN concentrations because of the complexities of atmospheric ice nucleation processes. Field measurements of IN concentrations with Continuous Flow Diffusion Chamber (CFDC) IN counters have been vital to constrain IN number concentrations and have led to various parameterizations of IN number vs. temperature and particle concentration. These parameterizations are used in many global climate models, which are very sensitive to the treatment of cloud microphysics. However, due to non-idealities in CFDC behavior, especially at high relative humidity, many of these measurements are likely biased too low. In this study, the extent of this low bias is examined with laboratory experiments at a variety of instrument conditions using the SPectrometer for Ice Nucleation, a commercially-available CFDC-style chamber. These laboratory results are compared to theoretical calculations and computational fluid dynamics models to map the variability of this bias as a function of chamber temperature and relative humidity.

  4. Three-Dimensional Concentration Measurements around Actively Tracking Blue Crabs

    NASA Astrophysics Data System (ADS)

    Dickman, B. D.; Jackson, J. L.; Weissburg, M. J.; Webster, D. R.

    2006-11-01

    Many aquatic arthropods locate food, suitable habitats, and mates solely through information extracted by chemical signals in their environment. Chemical plumes detected by larger animals are influenced by turbulence that creates an intermittent and unpredictable chemical stimulus environment. To link the stimulus pattern to behavior, we have developed a measurement system to quantify the instantaneous odor concentration surrounding a freely tracking blue crab through three-dimensional laser-induced fluorescence (3DLIF). A blue crab receives chemical stimulus at several locations, including the antennules near the mouth region and the distal tips of the legs and claws. Hence, three-dimensional measurements of the concentration field are required to link behavior to plume structure. During trials, crabs began their search 150 cm downstream of a source, and walking kinematics were recording simultaneously. The crabs were reversibly ``blindfolded'' during tracking to prevent aversive reactions to the intense laser light. Our experiments allow us to examine how hypothesized navigational cues, such as concentration bursts at the antennules and spatial asymmetry in concentration at the distributed chemosensory organs on the legs and claws, results in particular decisions during navigation.

  5. Characterization and Scaling of Black Carbon Aerosol Concentration with City Population Based on In-Situ Measurements and Analysis

    NASA Astrophysics Data System (ADS)

    Paredes-Miranda, G.; Arnott, W. P.; Moosmuller, H.

    2010-12-01

    The global trend toward urbanization and the resulting increase in city population has directed attention toward air pollution in megacities. A closely related question of importance for urban planning and attainment of air quality standards is how pollutant concentrations scale with city population. In this study, we use measurements of light absorption and light scattering coefficients as proxies for primary (i.e., black carbon; BC) and total (i.e., particulate matter; PM) pollutant concentration, to start addressing the following questions: What patterns and generalizations are emerging from our expanding data sets on urban air pollution? How does the per-capita air pollution vary with economic, geographic, and meteorological conditions of an urban area? Does air pollution provide an upper limit on city size? Diurnal analysis of black carbon concentration measurements in suburban Mexico City, Mexico, Las Vegas, NV, USA, and Reno, NV, USA for similar seasons suggests that commonly emitted primary air pollutant concentrations scale approximately as the square root of the urban population N, consistent with a simple 2-d box model. The measured absorption coefficient Babs is approximately proportional to the BC concentration (primary pollution) and thus scales with the square root of population (N). Since secondary pollutants form through photochemical reactions involving primary pollutants, they scale also with square root of N. Therefore the scattering coefficient Bsca, a proxy for PM concentration is also expected to scale with square root of N. Here we present light absorption and scattering measurements and data on meteorological conditions and compare the population scaling of these pollutant measurements with predictions from the simple 2-d box model. We find that these basin cities are connected by the square root of N dependence. Data from other cities will be discussed as time permits.

  6. High Frequency Measurements of Methane Concentrations and Carbon Isotopes at a Marsh and Landfill

    NASA Astrophysics Data System (ADS)

    Mortazavi, B.; Wilson, B.; Chanton, J.; Eller, K.; Dong, F.; Baer, D. S.; Gupta, M.; Dzwonkowski, B.

    2012-12-01

    High frequency measurements of methane concentrations and carbon isotopes can help constrain the source strengths of methane emitted to the atmosphere. We report here methane concentrations and 13C values measured at 0.5 Hz with cavity enhanced laser absorption spectrometers (Los Gatos Research) deployed at a saltmarsh in Alabama and a landfill in Florida. Methane concentrations and 13C at the saltmarsh were monitored over a 2.5 day time period at 2 m, 0.5 m above the ground as well as from the outflow of a flow-through (2 L) chamber placed on the Spartina alterniflora dominated marsh. A typical measurement cycle included regular samples from two tanks of known methane concentrations and isotopic values and from ambient air samples. Over the 2.5-day measurement period methane concentrations and isotopic ratios at 2 m averaged 1.85 ppm and -43.57‰ (±0.34, 1 SE), respectively. The concentration and isotopic values from the chamber outflow varied from 1.92 to 5.81 ppm and -38.5 to -59.3‰, respectively. Methane flux from the marsh ranged from undetectable to 3.6 mgC m-2hr-1, with high fluxes measured during low tide. The 13δCH4 of the emitted CH4 from the marsh, determined from a mass balance equation using the chamber inflow and outflow concentration and isotopic values ranged from -62.1 to -93.9‰ and averaged -77‰ (±1.25, 1SE). At the landfill ambient methane concentrations and 13C ratios measured over multiple days varied from 4.25 to 11.91 ppm and from -58.81 to -45.12‰, respectively. At higher methane concentrations the δ13C of CH4 was more depleted consistent with previously observed relationship at this site made by more traditional techniques. Over a 30-minute measurement period CH4 concentrations at the landfill could vary by as much as 15 ppm. The high frequency continuous optical measurements with field-deployed instruments provide us with an unprecedented temporal resolution of CH4 concentrations and isotopic ratios. These measurements will

  7. Measuring Low Concentrations of Liquid Water in Soil

    NASA Technical Reports Server (NTRS)

    Buehler, Martin

    2009-01-01

    An apparatus has been developed for measuring the low concentrations of liquid water and ice in relatively dry soil samples. Designed as a prototype of instruments for measuring the liquidwater and ice contents of Lunar and Martian soils, the apparatus could also be applied similarly to terrestrial desert soils and sands. The apparatus is a special-purpose impedance spectrometer: Its design is based on the fact that the electrical behavior of a typical soil sample is well approximated by a network of resistors and capacitors in which resistances decrease and capacitances increase (and, hence, the magnitude of impedance decreases) with increasing water content.

  8. Measuring Cytokine Concentrations Using Magnetic Spectroscopy of Nanoparticle Brownian Relaxation

    NASA Astrophysics Data System (ADS)

    Khurshid, Hafsa; Shi, Yipeng; Weaver, John

    The magnetic particle spectroscopy is a newly developed non-invasive technique for obtaining information about the nanoparticles' micro environment. In this technique the nanoparticles' magnetization, induced by an alternating magnetic field at various applied frequencies, is processed to analyze rotational freedom of nanoparticles. By analyzing average rotational freedom, it is possible to measure the nanoparticle's relaxation time, and hence get an estimate of the temperature and viscosity of the medium. In molecular concentration sensing, the rotational freedom indicates the number of nanoparticles that are bound by a selected analyte. We have developed microscopic nanoparticles probes to measure the concentration of selected molecules. The nanoparticles are targeted to bind the selected molecule and the resulting reduction in rotational freedom can be quantified remotely. Previously, sensitivity measurements has been reported to be of the factor of 200. However, with our newer perpendicular field setup (US Patent Application Serial No 61/721,378), it possible to sense cytokine concentrations as low as 5 Pico-Molar in-vitro. The excellent sensitivity of this apparatus is due to isolation of the drive field from the signal so the output can be amplified to a higher level. Dartmouth College.

  9. [Airborne Fungal Aerosol Concentration and Distribution Characteristics in Air- Conditioned Wards].

    PubMed

    Zhang, Hua-ling; Feng, He-hua; Fang, Zi-liang; Wang, Ben-dong; Li, Dan

    2015-04-01

    The effects of airborne fungus on human health in the hospital environment are related to not only their genera and concentrations, but also their particle sizes and distribution characteristics. Moreover, the mechanisms of aerosols with different particle sizes on human health are different. Fungal samples were obtained in medicine wards of Chongqing using a six-stage sampler. The airborne fungal concentrations, genera and size distributions of all the sampling wards were investigated and identified in detail. Results showed that airborne fungal concentrations were not correlated to the diseases or personnel density, but were related to seasons, temperature, and relative humidity. The size distribution rule had roughly the same for testing wards in winter and summer. The size distributions were not related with diseases and seasons, the percentage of airborne fungal concentrations increased gradually from stage I to stage III, and then decreased dramatically from stage V to stage VI, in general, the size of airborne fungi was a normal distribution. There was no markedly difference for median diameter of airborne fungi which was less 3.19 μm in these wards. There were similar dominant genera in all wards. They were Aspergillus spp, Penicillium spp and Alternaria spp. Therefore, attention should be paid to improve the filtration efficiency of particle size of 1.1-4.7 μm for air conditioning system of wards. It also should be targeted to choose appropriate antibacterial methods and equipment for daily hygiene and air conditioning system operation management.

  10. Modelling deposition and air concentration of reduced nitrogen in Poland and sensitivity to variability in annual meteorology.

    PubMed

    Kryza, Maciej; Dore, Anthony J; Błaś, Marek; Sobik, Mieczysław

    2011-04-01

    The relative contribution of reduced nitrogen to acid and eutrophic deposition in Europe has increased recently as a result of European policies which have been successful in reducing SO(2) and NO(x) emissions but have had smaller impacts on ammonia (NH(3)) emissions. In this paper the Fine Resolution Atmospheric Multi-pollutant Exchange (FRAME) model was used to calculate the spatial patterns of annual average ammonia and ammonium (NH(4)(+)) air concentrations and reduced nitrogen (NH(x)) dry and wet deposition with a 5 km × 5 km grid for years 2002-2005. The modelled air concentrations of NH(3) and dry deposition of NH(x) show similar spatial patterns for all years considered. The largest year to year changes were found for wet deposition, which vary considerably with precipitation amount. The FRAME modelled air concentrations and wet deposition are in reasonable agreement with available measurements (Pearson's correlation coefficients above 0.6 for years 2002-2005), and with spatial patterns of concentrations and deposition of NH(x) reported with the EMEP results, but show larger spatial gradients. The error statistics show that the FRAME model results are in better agreement with measurements if compared with EMEP estimates. The differences in deposition budgets calculated with FRAME and EMEP do not exceed 17% for wet and 6% for dry deposition, with FRAME estimates higher than for EMEP wet deposition for modelled period and lower or equal for dry deposition. The FRAME estimates of wet deposition budget are lower than the measurement-based values reported by the Chief Inspectorate of Environmental Protection of Poland, with the differences by approximately 3%. Up to 93% of dry and 53% of wet deposition of NH(x) in Poland originates from national sources. Over the western part of Poland and mountainous areas in the south, transboundary transport can contribute over 80% of total (dry + wet) NH(x) deposition. The spatial pattern of the relative contribution of

  11. Nitrogen potential recovery and concentration of ammonia from swine manure using electrodialysis coupled with air stripping.

    PubMed

    Ippersiel, D; Mondor, M; Lamarche, F; Tremblay, F; Dubreuil, J; Masse, L

    2012-03-01

    The practice of intensive animal production in certain areas has resulted in excessive manure production for the available regional land base. Consequently, there is a need to develop treatment technologies to recover the valuable nutrients that manure contains so that the resulting product can be transported and used as fertilizer on agricultural land. The project presented here used electrodialysis in a dilution/concentration configuration to transfer the manure ammonia in the diluate solution by electromigration to an adjacent solution separated by an ion-exchange membrane under the driving force of an electrical potential. Then, air stripping from the electrodialysis-obtained concentrate solution without pH modification was used to isolate the ammonia in an acidic solution. An optimal process operating voltage of 17.5 V was first determined on the basis of current efficiency and total energy consumption. During the process, the swine manure pH varied from 8.5 to 8.2, values favourable for NH(4)(+) electromigration. Total ammonia nitrogen reached 21,352 mg/L in the concentrate solution, representing approximately seven times the concentration in the swine manure. Further increases in concentration were limited by water transfer from the diluate solution due to electroosmosis and osmosis. Applying vacuum to the concentrate reservoir was found to be more efficient than direct concentrate solution aeration for NH(3) recuperation in the acid trap, given that the ammonia recuperated under vacuum represented 14.5% of the theoretical value of the NH(3) present in the concentrate solution as compared to 6.2% for aeration. However, an excessively low concentrate solution pH (8.6-8.3) limited NH(3)volatilization toward the acid trap. These results suggest that the concentrate solution pH needs to be raised to promote the volatile NH(3) form of total ammonia nitrogen.

  12. Seasonal variation in vertical volatile compounds air concentrations within a remote hemiboreal mixed forest

    NASA Astrophysics Data System (ADS)

    Noe, S. M.; Hüve, K.; Niinemets, Ü.; Copolovici, L.

    2011-05-01

    The vertical distribution of ambient biogenic volatile organic compounds (BVOC) concentrations within a hemiboreal forest canopy was investigated over a period of one year. Variability in temporal and spatial isoprene concentrations can be mainly explained by biogenic emissions from deciduous trees, ranging from 0.1 to 7.5 μg m-3. Monoterpene concentrations exceeded isoprene largely and ranged from 0.01 to 140 μg m-3 and during winter time anthropogenic contributions are likely. Variation in monoterpene concentrations found to be largest right above the ground and the vertical profile suggest a weak mixing leading to terpene accumulation in the lower canopy. Exceptionally high values were recorded during a heat wave in July 2010 with very high midday temperatures above 30 °C for several weeks. During summer months, monoterpene exceeded isoprene concentrations 6-fold and during winter 12-fold. The relative contribution of diverse monoterpene species to the ambient concentrations revealed a dominance of α-pinene in the lower and of limonene in the upper part of the canopy, both accounting for up to 70 % of the total monoterpene concentration during summer months. The main contributing monoterpene during wintertime was Δ3-carene accounting for 60 % of total monoterpene concentration in January. Possible biogenic monoterpene sources beside the foliage are the leaf litter, the soil and also resins exuding from stems. In comparison, the hemiboreal mixed forest canopy showed similar isoprene but higher monoterpene concentrations than the boreal forest and lower isoprene but substantially higher monoterpene concentrations than the temperate mixed forest canopies. These results have major implications for simulating air chemistry and secondary organic aerosol formation within and above hemiboreal forest canopies.

  13. Advances in Air-Sea Flux Measurement by Eddy Correlation

    NASA Astrophysics Data System (ADS)

    Blomquist, Byron W.; Huebert, Barry J.; Fairall, Christopher W.; Bariteau, Ludovic; Edson, James B.; Hare, Jeffrey E.; McGillis, Wade R.

    2014-09-01

    Eddy-correlation measurements of the oceanic flux are useful for the development and validation of air-sea gas exchange models and for analysis of the marine carbon cycle. Results from more than a decade of published work and from two recent field programs illustrate the principal interferences from water vapour and motion, demonstrating experimental approaches for improving measurement precision and accuracy. Water vapour cross-sensitivity is the greatest source of error for flux measurements using infrared gas analyzers, often leading to a ten-fold bias in the measured flux. Much of this error is not related to optical contamination, as previously supposed. While various correction schemes have been demonstrated, the use of an air dryer and closed-path analyzer is the most effective way to eliminate this interference. This approach also obviates density corrections described by Webb et al. (Q J R Meteorol 106:85-100, 1980). Signal lag and frequency response are a concern with closed-path systems, but periodic gas pulses at the inlet tip provide for precise determination of lag time and frequency attenuation. Flux attenuation corrections are shown to be 5 % for a cavity ring-down analyzer (CRDS) and dryer with a 60-m inlet line. The estimated flux detection limit for the CRDS analyzer and dryer is a factor of ten better than for IRGAs sampling moist air. While ship-motion interference is apparent with all analyzers tested in this study, decorrelation or regression methods are effective in removing most of this bias from IRGA measurements and may also be applicable to the CRDS.

  14. Prototype Systems for Measuring Outdoor Air Intake Rates in Rooftop Air Handlers

    SciTech Connect

    Fisk, William J.; Chan, Wanyu R.; Hotchi, Toshifumi

    2015-01-01

    The widespread absence of systems for real-time measurement and feedback control, of minimum outdoor air intake rates in HVAC systems contributes to the poor control of ventilation rates in commercial buildings. Ventilation rates affect building energy consumption and influence occupant health. The project designed fabricated and tested four prototypes of systems for measuring rates of outdoor air intake into roof top air handlers. All prototypes met the ±20% accuracy target at low wind speeds, with all prototypes accurate within approximately ±10% after application of calibration equations. One prototype met the accuracy target without a calibration. With two of four prototype measurement systems, there was no evidence that wind speed or direction affected accuracy; however, winds speeds were generally below usually 3.5 m s-1 (12.6 km h-1) and further testing is desirable. The airflow resistance of the prototypes was generally less than 35 Pa at maximum RTU air flow rates. A pressure drop of this magnitude will increase fan energy consumption by approximately 4%. The project did not have resources necessary to estimate costs of mass produced systems. The retail cost of components and materials used to construct prototypes ranged from approximately $1,200 to $1,700. The test data indicate that the basic designs developed in this project, particularly the designs of two of the prototypes, have considerable merit. Further design refinement, testing, and cost analysis would be necessary to fully assess commercial potential. The designs and test results will be communicated to the HVAC manufacturing community.

  15. Short-term 222Rn activity concentration changes in underground spaces with limited air exchange with the atmosphere

    NASA Astrophysics Data System (ADS)

    Fijałkowska-Lichwa, L.; Przylibski, T. A.

    2011-04-01

    The authors investigated short-time changes in 222Rn activity concentration occurring yearly in two underground tourist facilities with limited air exchange with the atmosphere. One of them is Niedźwiedzia (Bear) Cave in Kletno, Poland - a natural space equipped with locks ensuring isolation from the atmosphere. The other site is Fluorite Adit in Kletno, a section of a disused uranium mine. This adit is equipped with a mechanical ventilation system, operated periodically outside the opening times (at night). Both sites are situated within the same metamorphic rock complex, at similar altitudes, about 2 km apart. The measurements conducted revealed spring and autumn occurrence of convective air movements. In Bear Cave, this process causes a reduction in 222Rn activity concentration in the daytime, i.e. when tourists, guides and other staff are present in the cave. From the point of view of radiation protection, this is the best situation. For the rest of the year, daily concentrations of 222Rn activity in the cave are very stable. In Fluorite Adit, on the other hand, significant variations in daily 222Rn activity concentrations are recorded almost all year round. These changes are determined by the periods of activity and inactivity of mechanical ventilation. Unfortunately this is inactive in the daytime, which results in the highest values of 222Rn activity concentration at the times when tourists and staff are present in the adit. Slightly lower concentrations of radon in Fluorite Adit are recorded in the winter season, when convective air movements carry a substantial amount of radon out into the atmosphere. The incorrect usage of mechanical ventilation in Fluorite Adit results in the most unfavourable conditions in terms of radiation protection. The staff working in that facility are exposed practically throughout the year to the highest 222Rn activity concentrations, both at work (in the adit) and at home (outside their working hours). Therefore, not very well

  16. Calibration of NASA Turbulent Air Motion Measurement System

    NASA Technical Reports Server (NTRS)

    Barrick, John D. W.; Ritter, John A.; Watson, Catherine E.; Wynkoop, Mark W.; Quinn, John K.; Norfolk, Daniel R.

    1996-01-01

    A turbulent air motion measurement system (TAMMS) was integrated onboard the Lockheed 188 Electra airplane (designated NASA 429) based at the Wallops Flight Facility in support of the NASA role in global tropospheric research. The system provides air motion and turbulence measurements from an airborne platform which is capable of sampling tropospheric and planetary boundary-layer conditions. TAMMS consists of a gust probe with free-rotating vanes mounted on a 3.7-m epoxy-graphite composite nose boom, a high-resolution inertial navigation system (INS), and data acquisition system. A variation of the tower flyby method augmented with radar tracking was implemented for the calibration of static pressure position error and air temperature probe. Additional flight calibration maneuvers were performed remote from the tower in homogeneous atmospheric conditions. System hardware and instrumentation are described and the calibration procedures discussed. Calibration and flight results are presented to illustrate the overall ability of the system to determine the three-component ambient wind fields during straight and level flight conditions.

  17. Cleaning Products and Air Fresheners: Emissions and ResultingConcentrations of Glycol Ethers and Terpenoids

    SciTech Connect

    Singer, Brett C.; Destaillat, Hugo; Hodgson, Alfred T.; Nazaroff,William W.

    2005-08-01

    Experiments were conducted to quantify emissions and concentrations of glycol ethers and terpenoids from cleaning product and air freshener use in a 50-m{sup 3} room ventilated at {approx}0.5 h{sup -1}. Five cleaning products were applied full-strength (FS); three were additionally used in dilute solution. FS application of pine-oil cleaner (POC) yielded 1-h concentrations of 10-1300 {micro}g m{sup -3} for individual terpenoids, including {alpha}-terpinene (90-120), d-limonene (1000-1100), terpinolene (900-1300), and {alpha}-terpineol (260-700). One-hour concentrations of 2-butoxyethanol and/or dlimonene were 300-6000 {micro}g m{sup -3} after FS use of other products. During FS application including rinsing with sponge and wiping with towels, fractional emissions (mass volatilized/dispensed) of 2-butoxyethanol and d-limonene were 50-100% with towels retained, {approx}25-50% when towels were removed after cleaning. Lower fractions (2-11%) resulted from dilute use. Fractional emissions of terpenes from FS use of POC were {approx}35-70% with towels retained, 20-50% with towels removed. During floor cleaning with dilute solution of POC, 7-12% of dispensed terpenes were emitted. Terpene alcohols were emitted at lower fractions: 7-30% (FS, towels retained), 2-9% (FS, towels removed), and 2-5% (dilute). During air-freshener use, d-limonene, dihydromyrcenol, linalool, linalyl acetate, and {beta}-citronellol were emitted at 35-180 mg d{sup -1} over three days while air concentrations averaged 30-160 {micro}g m{sup -3}.

  18. Pt-TiO2/MWCNTs Hybrid Composites for Monitoring Low Hydrogen Concentrations in Air

    PubMed Central

    Trocino, Stefano; Donato, Andrea; Latino, Mariangela; Donato, Nicola; Leonardi, Salvatore Gianluca; Neri, Giovanni

    2012-01-01

    Hydrogen is a valuable fuel for the next energy scenario. Unfortunately, hydrogen is highly flammable at concentrations higher than 4% in air. This aspect makes the monitoring of H2 leaks an essential issue for safety reasons, especially in the transportation field. In this paper, nanocomposites based on Pt-doped TiO2/multiwalled carbon nanotubes (MWCNTs) have been introduced as sensitive materials for H2 at low temperatures. Pt-TiO2/MWNTs nanocomposites with different composition have been prepared by a simple wet chemical procedure and their morphological, microstructural and electrical properties were investigated. Resistive thick-film devices have been fabricated printing the hybrid nanocomposites on alumina substrates provided with Pt interdigitated electrodes. Electrical tests in air have shown that embedding MWCNTs in the TiO2 matrix modify markedly the electrical conductivity, providing a means to decrease the resistance of the sensing layer. Pt acts as a catalytic additive. Pt-TiO2/MWNTs-based sensors were found to be sensitive to hydrogen at concentrations between 0.5 and 3% in air, satisfying the requisites for practical applications in hydrogen leak detection devices.

  19. Modeling breathing-zone concentrations of airborne contaminants generated during compressed air spray painting.

    PubMed

    Flynn, M R; Gatano, B L; McKernan, J L; Dunn, K H; Blazicko, B A; Carlton, G N

    1999-01-01

    This paper presents a mathematical model to predict breathing-zone concentrations of airborne contaminants generated during compressed air spray painting in cross-flow ventilated booths. The model focuses on characterizing the generation and transport of overspray mist. It extends previous work on conventional spray guns to include exposures generated by HVLP guns. Dimensional analysis and scale model wind-tunnel studies are employed using non-volatile oils, instead of paint, to produce empirical equations for estimating exposure to total mass. Results indicate that a dimensionless breathing zone concentration is a nonlinear function of the ratio of momentum flux of air from the spray gun to the momentum flux of air passing through the projected area of the worker's body. The orientation of the spraying operation within the booth is also very significant. The exposure model requires an estimate of the contaminant generation rate, which is approximated by a simple impactor model. The results represent an initial step in the construction of more realistic models capable of predicting exposure as a mathematical function of the governing parameters. PMID:10028895

  20. Detonation propagation through methane-air mixtures with fuel concentration gradients

    NASA Astrophysics Data System (ADS)

    Kessler, David; Gamezo, Vadim; Oran, Elaine

    2010-11-01

    The complex structure of a multidimensional detonation front consists of constantly changing, multiply intersecting incident shocks and Mach stems followed by growing and shrinking regions of reacted and unreacted gases. Because these flow structures change in time, the energy release in the shocked and compressed gases varies in space and time. Trajectories of triple points formed at shock intersections create cellular patterns whose size and structure are characteristic of the particular material and the background condition. In high-activation-energy fuel-air mixtures, such as methane in air, cellular patterns are relatively large, very irregular, and have complex and changing substructures. Here we use numerical simulations to study the behavior of detonations propagating through methane-air mixtures with a spatial gradient of fuel concentration. When the mixture stoichiometry varies from stoichiometric, the detonation propagation speed slows and sizes of cellular structures grow. In partially premixed systems with a nonuniform concentration of fuel -- a condition that can occur, for example, naturally in sealed underground coal mine tunnels -- both the propagation speed and the characteristic detonation cell size vary spatially.