Science.gov

Sample records for air dried samples

  1. Application of a dry-gas meter for measuring air sample volumes in an ambient air monitoring network

    SciTech Connect

    Fritz, Brad G.

    2009-05-24

    Ambient air monitoring for non-research applications (e.g. compliance) occurs at locations throughout the world. Often, the air sampling systems employed for these purposes employee simple yet robust equipment capable of handling the rigors of demanding sampling schedules. At the Hanford Site (near Richland, Washington) concentrations of radionuclides in ambient air are monitored continuously at 44 locations. In 2004, mechanical dry-gas meters were incorporated into the Hanford Site ambient air sample collection system to allow the direct measurement of sample volumes. These meters replaced a portable airflow measurement system that required two manual flow measurements and a sample duration measurement to determine sample volume. A six-month evaluation of the dry-gas meters compared sample volumes calculated using the original flow rate method to the direct sample volume measurement (new method). The results of the evaluation indicate that use of the dry-gas meters result in accurate sample volume measurements and provide greater confidence in the measured sample volumes. In several years of in-network use, the meters have proven to be reliable and have resulted in an improved sampling system.

  2. Comparison of halocarbon measurements in an atmospheric dry whole air sample

    PubMed Central

    Hall, Bradley D.; Harth, Christina M.; Kim, Jin Seog; Lee, Jeongsoon; Montzka, Stephen A.; Mühle, Jens; Reimann, Stefan; Vollmer, Martin K.; Weiss, Ray F.

    2015-01-01

    The growing awareness of climate change/global warming, and continuing concerns regarding stratospheric ozone depletion, will require continued measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track atmospheric mole fractions and assess the impact of policy on emission rates, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. Precise measurements of these species aid in determining small changes in their atmospheric abundance. A common source of standards/scales and/or well-documented agreement of different scales used to calibrate the measurement instrumentation are key to understanding many sets of data reported by researchers. This report describes the results of a comparison study among National Metrology Institutes and atmospheric research laboratories for the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC-12), trichlorofluoromethane (CFC-11), and 1,1,2-trichlorotrifluoroethane (CFC-113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC-22) and 1-chloro-1,1-difluoroethane (HCFC-142b); and the hydrofluorocarbon (HFC) 1,1,1,2-tetrafluoroethane (HFC-134a), all in a dried whole air sample. The objective of this study is to compare calibration standards/scales and the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. The results of this study show agreement among four independent calibration scales to better than 2.5% in almost all cases, with many of the reported agreements being better than 1.0%. PMID:26753167

  3. ANALYSIS OF VOCS IN AMBIENT AIR USING MULTISORBENT PACKINGS FOR VOC ACCUMULATION AND SAMPLE DRYING

    EPA Science Inventory

    Solid multisorbent packings have been characterized for trapping and release efficiency of trace (10-20 ppbv in humidified zero air) volatile organic compounds (VOCs). he use of a two-stage trapping system reduces sample water content typically by more than 95.5% while maintainin...

  4. Early detection of foot-and-mouth disease virus from infected cattle using a dry filter air sampling system

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Foot-and-mouth disease (FMD) is a highly contagious livestock disease of high economic impact. Early detection of FMD virus (FMDV) is fundamental for rapid outbreak control. Air sampling collection has been demonstrated as a useful technique for detection of FMDV RNA in infected animals, related to ...

  5. HAZARDOUS AIR POLLUTANTS: DRY-DEPOSITION PHENOMENA

    EPA Science Inventory

    Dry-deposition rates were evaluated for two hazardous organic air pollutants, nitrobenzene and perchloroethylene, to determine their potential for removal from the atmosphere to three building material surfaces, cement, tar paper, and vinyl asbestos tile. Dry-deposition experimen...

  6. Air Sampling Filter

    NASA Technical Reports Server (NTRS)

    1980-01-01

    General Metal Works' Accu-Vol is a high-volume air sampling system used by many government agencies to monitor air quality for pollution control purposes. Procedure prevents possible test-invalidating contamination from materials other than particulate pollutants, caused by manual handling or penetration of windblown matter during transit, a cassette was developed in which the filter is sealed within a metal frame and protected in transit by a snap-on aluminum cover, thus handled only under clean conditions in the laboratory.

  7. High strength air-dried aerogels

    DOEpatents

    Coronado, Paul R.; Satcher, Jr., Joe H.

    2012-11-06

    A method for the preparation of high strength air-dried organic aerogels. The method involves the sol-gel polymerization of organic gel precursors, such as resorcinol with formaldehyde (RF) in aqueous solvents with R/C ratios greater than about 1000 and R/F ratios less than about 1:2.1. Using a procedure analogous to the preparation of resorcinol-formaldehyde (RF) aerogels, this approach generates wet gels that can be air dried at ambient temperatures and pressures. The method significantly reduces the time and/or energy required to produce a dried aerogel compared to conventional methods using either supercritical solvent extraction. The air dried gel exhibits typically less than 5% shrinkage.

  8. Osmo-air drying of aloe vera gel cubes.

    PubMed

    Pisalkar, P S; Jain, N K; Jain, S K

    2011-04-01

    Aloe vera (Aloe barbadensis Miller) cubes of 12.5 × 12.5 × 12.5 mm thick were osmosed for 4 h in sugar syrup of 30, 40 and 50°Brix concentration and temperatures of 30 and 50°C at constant syrup to fruit ratio of 5:1. Osmosed and unosmosed aloe vera samples were hot air dried at 50, 60, 70 and 80°C with constant air velocity of 1.5 m/s. The water loss, solid gain and convective drying behaviour were recorded during experiments. It was observed that water loss and solid gain ranged from 39.2 to 71.3 and 2.7 to 6.3%, respectively during osmo-drying. The moisture diffusivity varied from 2.9 to 8.0 × 10(-9) m²/s and 2.7 to 4.6 × 10(-9) m²/s during air drying of osmosed and unosmosed aloe vera samples, respectively. Drying air temperature and osmosis as pre-treatment affected the water loss, solid gain, diffusivity at -p ≤ 0.01. PMID:21350589

  9. Dry deposition of polycyclic aromatic hydrocarbons in ambient air

    SciTech Connect

    Sheu, H.L.; Lee, W.J.; Su, C.C.; Chao, H.R.; Fan, Y.C.

    1996-12-01

    Dry deposition and air sampling were undertaken, simultaneously, in the ambient air of an urban site and a petrochemical-industry (PCI) plant by using several dry deposition plates and PS-1 samplers from January to May 1994 in southern Taiwan. The dry deposition plate with a smooth surface was always pointed into the wind. Twenty-one polycyclic aromatic hydrocarbons (PAHs) were analyzed by a gas chromatography/mass spectrometer (GC/MSD). The dry deposition flux of total-PAHs in urban and PCI sites averaged 166 and 211 {micro}g/m{sup 2}{center_dot}d, respectively. In general, the PAH dry deposition flux increased with increases in the PAH concentration in the ambient air. The PAH pattern of dry deposition flux in both urban and PCI sites were similar to the pattern measured by the filter of the PS-1 sampler and completely different from the PAH pattern in the gas phase. The higher molecular weight PAHs have higher dry deposition velocities. This is due to the fact that higher molecular weight PAHs primarily associated with the particle phase are deposited mostly by gravitational settling, while the gas phase PAHs were between 0.001 and 0.010 cm/s, only the lower molecular-weight PAHs--Nap and AcPy--had a significant fraction of dry deposition flux contributed by the gas phase. All the remaining higher molecular-weight PAHs had more than 94.5% of their dry deposition flux resulting from the particle phase. This is due to the fact that higher molecular weight PAHs have a greater fraction in the particle phase and the dry deposition velocities of particulates are much higher than those of the gas phase.

  10. Drying kinetics, rehydration and colour characteristics of convective hot-air drying of carrot slices

    NASA Astrophysics Data System (ADS)

    Doymaz, İbrahim

    2016-03-01

    The effects of air drying temperature, slice thickness and pre-treatment application on the drying kinetics of carrot slices during convective drying in the range 50-70 °C were investigated. Results indicated that drying time, rehydration ratio and colour characteristics of carrot slices were more affected by drying air temperature, followed by pre-treatment applications. Five thin-layer drying models were applied to describe the drying kinetics. Midilli et al. model was the best model to characterize the drying kinetics of carrot slices. The moisture effective diffusivity calculated from the second Fick's law of diffusion ranged from 3.46 × 10-10 to 1.02 × 10-9 m2/s. The values of activation energy determined from the slope of the Arrhenius plot, ln(D eff ) versus 1/(T + 273.15), were 35.53, 43.42, and 37.75 kJ/mol for blanch, potas and control samples, respectively.

  11. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1987-12-10

    An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  12. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, Katharine H.

    1990-01-01

    An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry.

  13. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1990-05-22

    An inertial impactor is designed which is to be used in an air sampling device for collection of respirable size particles in ambient air. The device may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  14. Combustion gas properties. 2: Natural gas fuel and dry air

    NASA Technical Reports Server (NTRS)

    Wear, J. D.; Jones, R. E.; Trout, A. M.; Mcbride, B. J.

    1985-01-01

    A series of computations has been made to produce the equilibrium temperature and gas composition for natural gas fuel and dry air. The computed tables and figures provide combustion gas property data for pressures from 0.5 to 50 atmospheres and equivalence ratios from 0 to 2.0. Only samples tables and figures are provided in this report. The complete set of tables and figures is provided on four microfiche films supplied with this report.

  15. Sample drying effects on lead bioaccessibility in reduced soil.

    PubMed

    Furman, Olha; Strawn, Daniel G; McGeehan, Steve

    2007-01-01

    Risk-assessment tests of contaminated wetland soils often use experimental protocols that artificially oxidize the soils. Oxidation may impact bioavailability of contaminants from the soils, creating erroneous results and leading to improper management and remediation. The goal of this study was to determine if oxygenation of reduced sediments and soils influences Pb bioaccessibility measurements. The study site is located on the Coeur d'Alene River floodplain, downstream from the Silver Valley Mining District in Idaho. A physiologically based extraction test designed to simulate the gastrointestinal tract of waterfowl (W-PBET) was used to measure relative Pb bioavailability (bioaccessibility) from the soils. The soils were collected from a submerged wetland. One set of samples was allowed to air-dry, another set was freeze-dried, and a third set was analyzed wet. The wet soil showed decreased Pb bioaccessibility compared with the air- and freeze-dried soils. The changes in extractability of Fe and Mn on air-drying were opposite from each other: Fe extractability decreased while Mn increased. The results from this study show that redox changes may have significant impacts on Pb bioavailability, and should be considered when assessing Pb contamination risks in reduced soils. PMID:17485722

  16. 7 CFR 29.3503 - Air-dried.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Air-dried. 29.3503 Section 29.3503 Agriculture... INSPECTION Standards Official Standard Grades for Dark Air-Cured Tobacco (u.s. Types 35, 36, 37 and Foreign Type 95) § 29.3503 Air-dried. The condition of unfermented tobacco as customarily prepared for...

  17. 7 CFR 29.3503 - Air-dried.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Air-dried. 29.3503 Section 29.3503 Agriculture... INSPECTION Standards Official Standard Grades for Dark Air-Cured Tobacco (u.s. Types 35, 36, 37 and Foreign Type 95) § 29.3503 Air-dried. The condition of unfermented tobacco as customarily prepared for...

  18. 7 CFR 29.3503 - Air-dried.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Air-dried. 29.3503 Section 29.3503 Agriculture... INSPECTION Standards Official Standard Grades for Dark Air-Cured Tobacco (u.s. Types 35, 36, 37 and Foreign Type 95) § 29.3503 Air-dried. The condition of unfermented tobacco as customarily prepared for...

  19. 7 CFR 29.3503 - Air-dried.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Air-dried. 29.3503 Section 29.3503 Agriculture... INSPECTION Standards Official Standard Grades for Dark Air-Cured Tobacco (u.s. Types 35, 36, 37 and Foreign Type 95) § 29.3503 Air-dried. The condition of unfermented tobacco as customarily prepared for...

  20. 7 CFR 29.3503 - Air-dried.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Air-dried. 29.3503 Section 29.3503 Agriculture... INSPECTION Standards Official Standard Grades for Dark Air-Cured Tobacco (u.s. Types 35, 36, 37 and Foreign Type 95) § 29.3503 Air-dried. The condition of unfermented tobacco as customarily prepared for...

  1. 70. BUILDING NO. 555, AIR DRY HOUSE FOR DOUBLE BASE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    70. BUILDING NO. 555, AIR DRY HOUSE FOR DOUBLE BASE RIFLE AND CANNON POWDERS, LOOKING NORTH AT SOUTH CORNER. FAN ROOM WITH STEAM HEATER IN FOREGROUND RIGHT. COOPER ELBOW VENTS ON ROOF ARE FROM DRYING ROOMS. STEAM LINE IN FOREGROUND, POWDER WAS DRIED ON RACKS IN DRYING ROOMS VENTILATED WITH HOT AIR. - Picatinny Arsenal, 500 Area, Powder Factory & Power House, State Route 15 near I-80, Dover, Morris County, NJ

  2. Dry Air Entrainment into Hurricane Earl

    NASA Technical Reports Server (NTRS)

    Guillory, Anthony R.; Jedlovec, Gary J.; Atkinson, Robert J.; Hood, Robbie E.; LaFontaine, Frank J.

    2000-01-01

    Hurricane Earl formed in the Gulf of Mexico in September 1998. It quickly was upgraded from a tropical disturbance to tropical storm status and then to a hurricane. Earl possessed hybrid (tropical and extratropical) characteristics throughout its lifetime. The system maintained and erratic track, which led to wide variability in the operational track forecasts. It eventually made landfall on the Florida panhandle on 2 September and raced northeastward. During August and September 1998, NASA conducted the third Convection and Moisture Experiment (CAMEX-3). The experiment was focused on studying hurricanes with an emphasis toward developing a better understanding of their intensification and motion. Earl provides a unique opportunity to utilize high spatial and temporal resolution data collected from the DC-8 and high altitude ER-2 NASA platforms, which flew over Earl as it made landfall. These data can also be put into broader view provided by other instruments from the Geosychronous Operational Environmental Satellites (GOES) and the Tropical Rainfall Measuring Mission (TRMM) satellites. Hurricane Earl was affected by entrainment of dry air from the northwest. Hurricane Isis was intensifying and approaching the Mexican Pacific coast with its associated outflow potentially affecting the inflow into Earl as the storm neared Florida. In addition, a longwave synoptic trough circulation was present over the eastern U.S. Either or both of these could be responsible for the dry air into the system. This paper will focus on identifying the source of the dry by using upper-level wind and moisture fields derived from the GOES 6.7 um water vapor imagery. We will attempt to relate the large-scale observations to those from the NASA aircraft. An infrared instrument onboard the ER-2 also has a similar wavelength and may be able to confirm some of the GOES findings. In addition, a microwave radiometer with 4 channels focused on measuring precipitation and its associated ice

  3. The Impact of Dry Saharan Air on Tropical Cyclone Intensification

    NASA Technical Reports Server (NTRS)

    Braun, Scott A.

    2012-01-01

    The controversial role of the dry Saharan Air Layer (SAL) on tropical storm intensification in the Atlantic will be addressed. The SAL has been argued in previous studies to have potential positive influences on storm development, but most recent studies have argued for a strong suppressing influence on storm intensification as a result of dry air, high stability, increased vertical wind shear, and microphysical impacts of dust. Here, we focus on observations of Hurricane Helene (2006), which occurred during the NASA African Monsoon Multidisciplinary Activities (NAMMA) experiment. Satellite and airborne observations, combined with global meteorological analyses depict the initial environment of Helene as being dominated by the SAL, although with minimal evidence that the SAL air actually penetrated to the core of the disturbance. Over the next several days, the SAL air quickly moved westward and was gradually replaced by a very dry, dust-free layer associated with subsidence. Despite the wrapping of this very dry air around the storm, Helene intensified steadily to a Category 3 hurricane suggesting that the dry air was unable to significantly slow storm intensification. Several uncertainties remain about the role of the SAL in Helene (and in tropical cyclones in general). To better address these uncertainties, NASA will be conducting a three year airborne campaign called the Hurricane and Severe Storm Sentinel (HS3). The HS3 objectives are: To obtain critical measurements in the hurricane environment in order to identify the role of key factors such as large-scale wind systems (troughs, jet streams), Saharan air masses, African Easterly Waves and their embedded critical layers (that help to isolate tropical disturbances from hostile environments). To observe and understand the three-dimensional mesoscale and convective-scale internal structures of tropical disturbances and cyclones and their role in intensity change. The mission objectives will be achieved using

  4. Ultrasound-Assisted Hot Air Drying of Foods

    NASA Astrophysics Data System (ADS)

    Mulet, Antonio; Cárcel, Juan Andrés; García-Pérez, José Vicente; Riera, Enrique

    This chapter deals with the application of power ultrasound, also named high-intensity ultrasound, in the hot air drying of foods. The aim of ultrasound-assisted drying is to overcome some of the limitations of traditional convective drying systems, especially by increasing drying rate without reducing quality attributes. The effects of ultrasound on drying rate are responsible for some of the phenomena produced in the internal and/or external resistance to mass transfer.

  5. Optimization of microwave-assisted hot air drying conditions of okra using response surface methodology.

    PubMed

    Kumar, Deepak; Prasad, Suresh; Murthy, Ganti S

    2014-02-01

    Okra (Abelmoschus esculentus) was dried to a moisture level of 0.1 g water/g dry matter using a microwave-assisted hot air dryer. Response surface methodology was used to optimize the drying conditions based on specific energy consumption and quality of dried okra. The drying experiments were performed using a central composite rotatable design for three variables: air temperature (40-70 °C), air velocity (1-2 m/s) and microwave power level (0.5-2.5 W/g). The quality of dried okra was determined in terms of color change, rehydration ratio and hardness of texture. A second-order polynomial model was well fitted to all responses and high R(2) values (>0.8) were observed in all cases. The color change of dried okra was found higher at high microwave power and air temperatures. Rehydration properties were better for okra samples dried at higher microwave power levels. Specific energy consumption decreased with increase in microwave power due to decrease in drying time. The drying conditions of 1.51 m/s air velocity, 52.09 °C air temperature and 2.41 W/g microwave power were found optimum for product quality and minimum energy consumption for microwave-convective drying of okra. PMID:24493879

  6. Air Sampling System Evaluation Template

    2000-05-09

    The ASSET1.0 software provides a template with which a user can evaluate an Air Sampling System against the latest version of ANSI N13.1 "Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities". The software uses the ANSI N13.1 PIC levels to establish basic design criteria for the existing or proposed sampling system. The software looks at such criteria as PIC level, type of radionuclide emissions, physical state ofmore » the radionuclide, nozzle entrance effects, particulate transmission effects, system and component accuracy and precision evaluations, and basic system operations to provide a detailed look at the subsystems of a monitoring and sampling system/program. A GAP evaluation can then be completed which leads to identification of design and operational flaws in the proposed systems. Corrective measures can then be limited to the GAPs.« less

  7. 7 CFR 29.3003 - Air-dried.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Air-dried. 29.3003 Section 29.3003 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Air-dried. The condition of unfermented tobacco as customarily prepared for storage under...

  8. 7 CFR 29.2502 - Air-dried.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Air-dried. 29.2502 Section 29.2502 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2502 Air-dried. The condition of...

  9. 7 CFR 29.2502 - Air-dried.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Air-dried. 29.2502 Section 29.2502 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2502 Air-dried. The condition of...

  10. 7 CFR 29.2502 - Air-dried.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Air-dried. 29.2502 Section 29.2502 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2502 Air-dried. The condition of...

  11. 7 CFR 29.3003 - Air-dried.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Air-dried. 29.3003 Section 29.3003 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Air-dried. The condition of unfermented tobacco as customarily prepared for storage under...

  12. 7 CFR 29.3003 - Air-dried.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Air-dried. 29.3003 Section 29.3003 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Air-dried. The condition of unfermented tobacco as customarily prepared for storage under...

  13. 7 CFR 29.3003 - Air-dried.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Air-dried. 29.3003 Section 29.3003 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Air-dried. The condition of unfermented tobacco as customarily prepared for storage under...

  14. 7 CFR 29.2502 - Air-dried.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Air-dried. 29.2502 Section 29.2502 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2502 Air-dried. The condition of...

  15. 7 CFR 29.3003 - Air-dried.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Air-dried. 29.3003 Section 29.3003 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Air-dried. The condition of unfermented tobacco as customarily prepared for storage under...

  16. 7 CFR 29.2502 - Air-dried.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Air-dried. 29.2502 Section 29.2502 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2502 Air-dried. The condition of...

  17. 74. BUILDING NO. 555, AIR DRY HOUSE FOR DOUBLE BASE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    74. BUILDING NO. 555, AIR DRY HOUSE FOR DOUBLE BASE RIFLE AND CANNON POWDERS, DETAIL OF WOODEN DRYING ROOM DOORS WITH WOODEN HINGES AND BOLTS FOR SPARK PREVENTION. RINGS BY DOORS TURN ON HOT AIR FLOW TO DRYING ROOMS. NOTE GROUNDING WIRE FROM RING BRACKETS. RECORDING MACHINES BY DOORS RECORD HUMIDITY IN DRYING ROOMS. DRYING ROOMS ILLUMINATED ONLY BY EXPLOSION-PROOF LIGHTING LOCATED OUTSIDE OF ROOMS. NOTE WOODEN RAILROAD RAILS IN BACKGROUND FOR 3 FT. GUAGE CARS. - Picatinny Arsenal, 500 Area, Powder Factory & Power House, State Route 15 near I-80, Dover, Morris County, NJ

  18. 75. BUILDING NO. 555, AIR DRY HOUSE FOR DOUBLE BASE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    75. BUILDING NO. 555, AIR DRY HOUSE FOR DOUBLE BASE RIFLE AND CANNON POWDERS, INTERIOR OF DRYING ROOM NO. 2, SHOWING COPPER EXHAUST VENT DUCT IN CORNER, HOT AIR INLET VENT IN CEILING. TWO TYPICAL DRYING RACKS LEANING AGAINST WALL, BOTTOM SIDE SHOWING ON LEFT RACK, TOP SIDE ON RIGHT RACK. - Picatinny Arsenal, 500 Area, Powder Factory & Power House, State Route 15 near I-80, Dover, Morris County, NJ

  19. 47. View of "dry air inlets" to waveguides entering scanner ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    47. View of "dry air inlets" to waveguides entering scanner building 105. Dried air is generated under pressure by Ingersoll-Rand dehumidified/dessicator and compressor system. View is at entrance from passageway that links into corner of scanner building. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  20. Hot air drying of apple slices: dehydration characteristics and quality assessment

    NASA Astrophysics Data System (ADS)

    Beigi, Mohsen

    2015-08-01

    The main objectives of the present study were to investigate the drying characteristics and quality attributes of apple slices. The samples were dried at different air temperature levels (50, 60 and 70 °C) and a constant air velocity (1.5 m s-1). It was observed that the drying air temperature affected the dehydration rate significantly. The usefulness of eight different mathematical models to simulate the experimental drying curves was evaluated and the Midilli model provided the best simulation of the samples drying kinetics. The effective moisture diffusivity was determined to be 7.03 × 10-10, 8.48 × 10-10 and 1.08 × 10-9 m2 s-1 for drying air temperatures of 50, 60 and 70 °C, respectively. The shrinkage values of the dried samples at air temperatures of 50, 60 and 70 °C were 74.70, 82.35 and 80.78 %, respectively. The maximum value of rehydration ratio (4.527) and also the minimum value of ∆E (11.27) were obtained for the slices dried at 70 °C.

  1. Hot air drying of apple slices: dehydration characteristics and quality assessment

    NASA Astrophysics Data System (ADS)

    Beigi, Mohsen

    2016-08-01

    The main objectives of the present study were to investigate the drying characteristics and quality attributes of apple slices. The samples were dried at different air temperature levels (50, 60 and 70 °C) and a constant air velocity (1.5 m s-1). It was observed that the drying air temperature affected the dehydration rate significantly. The usefulness of eight different mathematical models to simulate the experimental drying curves was evaluated and the Midilli model provided the best simulation of the samples drying kinetics. The effective moisture diffusivity was determined to be 7.03 × 10-10, 8.48 × 10-10 and 1.08 × 10-9 m2 s-1 for drying air temperatures of 50, 60 and 70 °C, respectively. The shrinkage values of the dried samples at air temperatures of 50, 60 and 70 °C were 74.70, 82.35 and 80.78 %, respectively. The maximum value of rehydration ratio (4.527) and also the minimum value of ∆E (11.27) were obtained for the slices dried at 70 °C.

  2. AIR TEMPERATURE DISTRIBUTION IN SEED COTTON DRYING SYSTEMS

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Ten tests were conducted in the fall of 2007 to measure air temperature variation within various heated air seed cotton drying systems with the purpose of: checking validation of recommendations by a professional engineering society and measuring air temperature variation across the airflow ductwork...

  3. Comparison of the effects of gamma radiation on hydrated and air dried rye grass seeds

    SciTech Connect

    Worthington, M.

    1988-01-01

    This is a comparative study of the effects of gamma radiation on the growth of hydrated and air dried seeds during the first weeks of primary growth. Four groups of seeds were used in the study: 1) hydrated sweet corn, 2) air dried sweet corn, 3) hydrated rye grass, and 4) air dried rye grass. Each group was then further subdivided and exposed to various levels of gamma radiation using a Cobalt-60 irradiator, except for the control samples of the four groups which received no radiation above background level. All seeds samples were then planted, allowed to grow for approximately 12 days, and harvested. Growth of both shoot and root of each seed was recorded for data analysis according to specific groups. Analyses of data from this study shows that the mean growth of air dried seeds when exposed to gamma radiation prior to planting.

  4. Mass transfer characteristics of bisporus mushroom ( Agaricus bisporus) slices during convective hot air drying

    NASA Astrophysics Data System (ADS)

    Ghanbarian, Davoud; Baraani Dastjerdi, Mojtaba; Torki-Harchegani, Mehdi

    2016-05-01

    An accurate understanding of moisture transfer parameters, including moisture diffusivity and moisture transfer coefficient, is essential for efficient mass transfer analysis and to design new dryers or improve existing drying equipments. The main objective of the present study was to carry out an experimental and theoretical investigation of mushroom slices drying and determine the mass transfer characteristics of the samples dried under different conditions. The mushroom slices with two thicknesses of 3 and 5 mm were dried at air temperatures of 40, 50 and 60 °C and air flow rates of 1 and 1.5 m s-1. The Dincer and Dost model was used to determine the moisture transfer parameters and predict the drying curves. It was observed that the entire drying process took place in the falling drying rate period. The obtained lag factor and Biot number indicated that the moisture transfer in the samples was controlled by both internal and external resistance. The effective moisture diffusivity and the moisture transfer coefficient increased with increasing air temperature, air flow rate and samples thickness and varied in the ranges of 6.5175 × 10-10 to 1.6726 × 10-9 m2 s-1 and 2.7715 × 10-7 to 3.5512 × 10-7 m s-1, respectively. The validation of the Dincer and Dost model indicated a good capability of the model to describe the drying curves of the mushroom slices.

  5. Air sampling in the workplace. Final report

    SciTech Connect

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC`s Regulatory Guide 8.25, Revision 1, ``Air sampling in the Workplace.`` That guide addresses air sampling to meet the requirements in NRC`s regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed.

  6. Gaseous fuels production from dried sewage sludge via air gasification.

    PubMed

    Werle, Sebastian; Dudziak, Mariusz

    2014-06-17

    Gasification is a perspective alternative method of dried sewage sludge thermal treatment. For the purpose of experimental investigations, a laboratory fixed-bed gasifier installation was designed and built. Two sewage sludge (SS) feedstocks, taken from two typical Polish wastewater treatment systems, were analysed: SS1, from a mechanical-biological wastewater treatment system with anaerobic stabilization (fermentation) and high temperature drying; and (SS2) from a mechanical-biological-chemical wastewater treatment system with fermentation and low temperature drying. The gasification results show that greater oxygen content in sewage sludge has a strong influence on the properties of the produced gas. Increasing the air flow caused a decrease in the heating value of the produced gas. Higher hydrogen content in the sewage sludge (from SS1) affected the produced gas composition, which was characterized by high concentrations of combustible components. In the case of the SS1 gasification, ash, charcoal, and tar were produced as byproducts. In the case of SS2 gasification, only ash and tar were produced. SS1 and solid byproducts from its gasification (ash and charcoal) were characterized by lower toxicity in comparison to SS2. However, in all analysed cases, tar samples were toxic. PMID:24938297

  7. Energy conservation by partial recirculation of peanut drying air

    SciTech Connect

    Young, J.H.

    1983-06-01

    Conventional, recirculating, and intermittent type peanut dryers were compared in a three-year study. Comparisons indicate that partial recirculation of peanut drying air may reduce energy consumption per unit of water removed by approximately 25% while also reducing required drying time and maintaining high quality.

  8. 73. BUILDING NO. 555, AIR DRY HOUSE FOR DOUBLE BASE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    73. BUILDING NO. 555, AIR DRY HOUSE FOR DOUBLE BASE RIFLE AND CANNON POWDERS, NORTHEAST ELEVATION, EACH COOPER ELBOW VENT ON THE ROOF COMES FROM A DRYING ROOM. - Picatinny Arsenal, 500 Area, Powder Factory & Power House, State Route 15 near I-80, Dover, Morris County, NJ

  9. Microwave application on air drying of apple (var. Granny Smith). The influence of vacuum impregnation pretreatment

    NASA Astrophysics Data System (ADS)

    Martin Esparza, Maria Eugenia

    Combined hot air-microwave drying has been studied on apple (var. Granny Smith), with and without vacuum impregnation (VI) pretreatment with isotonic solution, respect to kinetics, microstructural and final quality items. In order to reach this objective, a drier has been designed and built, that allows to control and to register all the variables which take place during the drying process. Thermal and dielectric properties, that are very important characteristics when studying heat and mass transfer phenomena that occur during the combined drying process, have been related to temperature and/or moisture content throughout empirical equations. It could be observed that all these properties decreased with product moisture content. Respect to dielectric properties, a relationship among water binding forms to food structure and water molecules relaxation frequency has been found. On the other hand, the effect of drying treatment conditions (air rate, drying temperature, sample thickness and incident microwave power) on the drying rate, from an empirical model based on diffusional mechanisms with two kinetic parameters (k1 and k2), both function of the incident microwave power, has been studied. Microwave application to air drying implied a notable decrease on drying time, the higher the applied power the higher the reduction. Microstructural study by Cryo-Sem revealed fast water vaporization taking place when microwaves are applied. Vacuum impregnation did not implied an additional advantage for combined drying as drying rate was similar to that of NIV samples. Finally, it has been studied the influence of process conditions on the color and mechanical properties of the dried product (IV and NIV). Vacuum impregnation implied an increase on the fracture resistance and less purity and tone angle. Microwave application induced product browning with respect to air drying (tone decreased and purity increased).

  10. The influence of sample drying procedures on mercury concentrations analyzed in soils.

    PubMed

    Hojdová, Maria; Rohovec, Jan; Chrastný, Vladislav; Penížek, Vít; Navrátil, Tomáš

    2015-05-01

    Methods commonly used for soil sample preparation may be unsuitable for measuring Hg concentrations due to the possible loss of volatile Hg species when drying at higher temperatures. Here, the effects of freeze-drying, air drying at 25°C and oven-drying at 105°C on Hg concentrations in two soil types and three standard reference materials were tested. Two soils with different levels of Hg contamination and three reference materials were examined. A systematic decrease of Hg concentrations was observed in air-dried (24 %) and oven-dried (3 %) contaminated upland soils in comparison to freeze-dried control samples. The 105°C oven drying also led to loss of Hg from reference materials (5 %-8 % in comparison with the certified Hg concentration). Different results from the drying of sterilized reference materials and natural soils were probably related to the extent of microbiological activity, demonstrating the importance of this parameter in sample preparation for Hg analysis. PMID:25786366

  11. Cold Vacuum Drying Instrument Air System Design Description (SYS 12)

    SciTech Connect

    SHAPLEY, B.J.; TRAN, Y.S.

    2000-06-05

    This system design description (SDD) addresses the instrument air (IA) system of the spent nuclear fuel (SNF). This IA system provides instrument quality air to the Cold Vacuum Drying (CVD) Facility. The IA system is a general service system that supports the operation of the heating, ventilation, and air conditioning (HVAC) system, the process equipment skids, and process instruments in the CVD Facility. The following discussion is limited to the compressor, dryer, piping, and valving that provide the IA as shown in Drawings H-1-82222, Cold Vacuum Drying Facility Mechanical Utilities Compressed & Instrument Air P&ID, and H-1.82161, Cold Vacuum Drying Facility Process Equipment Skid P&ID MCO/Cusk Interface. Figure 1-1 shows the physical location of the 1A system in the CVD Facility.

  12. Airway blood flow response to dry air hyperventilation in sheep

    SciTech Connect

    Parsons, G.H.; Baile, E.M.; Pare, P.D.

    1986-03-01

    Airway blood flow (Qaw) may be important in conditioning inspired air. To determine the effect of eucapneic dry air hyperventilation (hv) on Qaw in sheep the authors studied 7 anesthetized open-chest sheep after 25 min. of warm dry air hv. During each period of hv the authors have recorded vascular pressures, cardiac output (CO), and tracheal mucosal and inspired air temperature. Using a modification of the reference flow technique radiolabelled microspheres were injected into the left atrium to make separate measurements after humid air and dry air hv. In 4 animals a snare around the left main pulmonary artery was used following microsphere injection to prevent recirculation (entry into L lung of microspheres from the pulmonary artery). Qaw to the trachea and L lung as measured and Qaw for the R lung was estimated. After the final injection the sheep were killed and bronchi (Br) and lungs removed. Qaw (trachea plus L lung plus R lung) in 4 sheep increased from a mean of 30.8 to 67.0 ml/min. Airway mucosal temp. decreased from 39/sup 0/ to 33/sup 0/C. The authors conclude that dry air hv cools airway mucosa and increases Qaw in sheep.

  13. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  14. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 9 2014-07-01 2014-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  15. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  16. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  17. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  18. Development of a distributed air pollutant dry deposition modeling framework.

    PubMed

    Hirabayashi, Satoshi; Kroll, Charles N; Nowak, David J

    2012-12-01

    A distributed air pollutant dry deposition modeling system was developed with a geographic information system (GIS) to enhance the functionality of i-Tree Eco (i-Tree, 2011). With the developed system, temperature, leaf area index (LAI) and air pollutant concentration in a spatially distributed form can be estimated, and based on these and other input variables, dry deposition of carbon monoxide (CO), nitrogen dioxide (NO(2)), sulfur dioxide (SO(2)), and particulate matter less than 10 microns (PM10) to trees can be spatially quantified. Employing nationally available road network, traffic volume, air pollutant emission/measurement and meteorological data, the developed system provides a framework for the U.S. city managers to identify spatial patterns of urban forest and locate potential areas for future urban forest planting and protection to improve air quality. To exhibit the usability of the framework, a case study was performed for July and August of 2005 in Baltimore, MD. PMID:22858662

  19. Drying kinetics and mathematical modeling of hot air drying of coconut coir pith.

    PubMed

    Fernando, J A K M; Amarasinghe, A D U S

    2016-01-01

    Drying kinetics of coir pith was studied and the properties of compressed coir pith discs were analyzed. Coir pith particles were oven dried in the range of temperatures from 100 to 240 °C and the rehydration ability of compressed coir pith was evaluated by finding the volume expansion. The optimum drying temperature was found to be 140 °C. Hot air drying was carried out to examine the drying kinetics by allowing the coir pith particles to fluidize and circulate inside the drying chamber. Particle motion within the drying chamber closely resembled the particle motion in a flash dryer. The effective moisture diffusivity was found to increase from 1.18 × 10(-8) to 1.37 × 10(-8) m(2)/s with the increase of air velocity from 1.4 to 2.5 m/s respectively. Correlation analysis and residual plots were used to determine the adequacy of existing mathematical models for describing the drying behavior of coir pith. The empirical models, Wang and Singh model and Linear model, were found to be adequate for accurate prediction of drying behavior of coir pith. A new model was proposed by modifying the Wang and Singh model and considering the effect of air velocity. It gave the best correlation between observed and predicted moisture ratio with high value of coefficient of determination (R(2)) and lower values of root mean square error, reduced Chi square (χ(2)) and mean relative deviation (E%). PMID:27390647

  20. 7 CFR 29.2252 - Air-dried.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Air-dried. 29.2252 Section 29.2252 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Official Standard Grades for Virginia Fire-Cured Tobacco (u.s. Type 21) § 29.2252...

  1. 7 CFR 29.2252 - Air-dried.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Air-dried. 29.2252 Section 29.2252 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Official Standard Grades for Virginia Fire-Cured Tobacco (u.s. Type 21) § 29.2252...

  2. 7 CFR 29.2252 - Air-dried.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Air-dried. 29.2252 Section 29.2252 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Official Standard Grades for Virginia Fire-Cured Tobacco (u.s. Type 21) § 29.2252...

  3. 7 CFR 29.2252 - Air-dried.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Air-dried. 29.2252 Section 29.2252 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Official Standard Grades for Virginia Fire-Cured Tobacco (u.s. Type 21) § 29.2252...

  4. 7 CFR 29.2252 - Air-dried.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Air-dried. 29.2252 Section 29.2252 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Official Standard Grades for Virginia Fire-Cured Tobacco (u.s. Type 21) § 29.2252...

  5. A novel method for air drying aloe leaf slices by covering with filter papers as a shrink-proof layer.

    PubMed

    Kim, S A; Baek, J H; Lee, S J; Choi, S Y; Hur, W; Lee, S Y

    2009-01-01

    To prevent the shrinkage of aloe vera slices during air drying, a method utilizing a shrink-proof layer was developed. The sample was configured of whole leaf aloe slices, where 1 side or both sides were covered with filter papers as shrink-proof layers. After air drying by varying the air temperature and the slice thickness, the drying characteristics, as well as several quality factors of the dried aloe vera leaf slices, were analyzed. In the simulation of the drying curves, the modified Page model showed the best fitness, representing a diffusion-controlled drying mechanism. Nonetheless, there was a trace of a constant-rate drying period in the samples dried by the method. Shrinkage was greatly reduced, and the rehydration ratios increased by approximately 50%. Scanning electron microscopic analysis revealed that the surface structure of original fibrous form was well sustained. FT-IR characteristics showed that the dried samples could sustain aloe polysaccharide acetylation. Furthermore, the functional properties of the dried slices including water holding capacity, swelling, and fat absorption capability were improved, and polysaccharide retention levels increased by 20% to 30%. Therefore, we concluded that application of shrink-proof layers on aloe slices provides a novel way to overcome the shrinkage problems commonly found in air drying, thereby improving their functional properties with less cost. Practical Application: This research article demonstrates a novel air drying method using shrink-proof layers to prevent the shrinkage of aloe slices. We analyzed extensively the characteristics of shrinkage mechanism and physical properties of aloe flesh gels in this drying system. We concluded that this method can be a beneficial means to retain the functional properties of dried aloe, and a potential alternative to freeze drying, which is still costly. PMID:20492108

  6. Dry coolers and air-condensing units (Review)

    NASA Astrophysics Data System (ADS)

    Milman, O. O.; Anan'ev, P. A.

    2016-03-01

    The analysis of factors affecting the growth of shortage of freshwater is performed. The state and dynamics of the global market of dry coolers used at electric power plants are investigated. Substantial increase in number and maximum capacity of air-cooled condensers, which have been put into operation in the world in recent years, are noted. The key reasons facilitating the choice of developers of the dry coolers, in particular the independence of the location of thermal power plant from water sources, are enumerated. The main steam turbine heat removal schemes using air cooling are considered, their comparison of thermal efficiency is assessed, and the change of three important parameters, such as surface area of heat transfer, condensate pump flow, and pressure losses in the steam exhaust system, are estimated. It is shown that the most effective is the scheme of direct steam condensation in the heat-exchange tubes, but other schemes also have certain advantages. The air-cooling efficiency may be enhanced much more by using an air-cooling hybrid system: a combination of dry and wet cooling. The basic applied constructive solutions are shown: the arrangement of heat-exchange modules and the types of fans. The optimal mounting design of a fully shopassembled cooling system for heat-exchange modules is represented. Different types of heat-exchange tubes ribbing that take into account the operational features of cooling systems are shown. Heat transfer coefficients of the plants from different manufacturers are compared, and the main reasons for its decline are named. When using evaporative air cooling, it is possible to improve the efficiency of air-cooling units. The factors affecting the faultless performance of dry coolers (DC) and air-condensing units (ACU) and the ways of their elimination are described. A high velocity wind forcing reduces the efficiency of cooling systems and creates preconditions for the development of wind-driven devices. It is noted that

  7. The effect of pretreatments on air drying characteristics of persimmons

    NASA Astrophysics Data System (ADS)

    Demiray, Engin; Tulek, Yahya

    2016-03-01

    In this study, whole and peeled persimmons were dried in the ranges of 55-75 °C of drying temperature in a hot air dryer. The effect of drying temperature and pretreatments on the drying characteristics was determined. Immersing in a solution of 20 % sucrose resulted in an increase in the drying rate of persimmons. A non-linear regression procedure was used to fit five thin-layer drying models available in the literature to the experimental moisture loss data. The Page and Modified Page models have shown a better fit to the experimental drying data as compared to other models. The effective diffusivity was determined to be 9.237 × 10-10-10.395 × 10-10 m2 s-1 for the blanched persimmons and 7.755 × 10-10-9.631 × 10-10 m2 s-1 for immersed sucrose solution persimmons. The activation energies for diffusion were calculated to be 56.09 kJ mol-1 (for blanched) and 10.28 kJ mol-1 (for immersed sucrose solution).

  8. Combustion gas properties. Part 3: Hydrogen gas fuel and dry air

    NASA Technical Reports Server (NTRS)

    Wear, J. D.; Jones, R. E.; Mcbride, B. J.; Beyerle, R. A.

    1985-01-01

    A series of computations has been made to produce the equilibrium temperature and gas composition for hydrogen gas fuel and dry air. The computed tables and figures provide combustion gas property data for pressures from 0.5 to 50 atmospheres and equivalence ratios from 0 to 2.0. Only sample tables and figures are provided in this report.

  9. Dry deposition modelling of air pollutants over urban areas

    NASA Astrophysics Data System (ADS)

    Cherin, N.; Roustan, Y.; Seigneur, C.; Musson Genon, L.

    2012-04-01

    More than one-half of the world's inhabitants lives in urban areas. Consequently, the evolution of pollutants inside these urban areas are problems of great concern in air quality studies. Though the dry deposition fluxes of air pollutants, which are known to be significant in the neighborhood of sources of pollution, like urban areas, have not been modeled precisely until recently within urban areas. By reviewing the physics of the processes leading to the dry deposition of air pollutants, it is clear that atmosphere turbulence is crucial for dry deposition. Urban areas, and particularly buildings, are known to significantly impact flow fields and then by extension the dry deposition fluxes. Numerous urban schemes have been developed in the past decades to approximate the effect of the local scale urban elements on drag, heat flux and radiative budget. The most recent urban canopy models are based on quite simple geometries, but sufficiently close to represent the aerodynamic and thermal characteristics of cities. These canopy models are generally intended to parameterize aerodynamic and thermal fields, but not dry deposition. For dry deposition, the current classical "roughness" approach, uses only two representative parameters, z0 and d, namely the roughness length and the zero-plane displacement height to represent urban areas. In this work, an innovative dry deposition model based on the urban canyon concept, is proposed. It considers a single road, bordered by two facing buildings, which are treated separately. It accounts for sub-grid effects of cities, especially a better parameterization of the turbulence scheme, through the use of local mixing length and a more detailled description of the urban area and key parameters within the urban canopy. Three different flow regimes are distinguished in the urban canyon according to the height-to-width ratio: isolated roughness flow, wake interference flow and skimming flow regime. The magnitude of differences in

  10. Cumulative ventilation air drying potential as an indication of dry mass content in wastewater sludge in a thin-layer solar drying facility

    NASA Astrophysics Data System (ADS)

    Krawczyk, Piotr

    2013-12-01

    Controlling low-temperature drying facilities which utilise nonprepared air is quite difficult, due to very large variability of ventilation air parameters - both in daily and seasonal cycles. The paper defines the concept of cumulative drying potential of ventilation air and presents experimental evidence that there is a relation between this parameter and condition of the dried matter (sewage sludge). Knowledge on current dry mass content in the dried matter (sewage sludge) provides new possibilities for controlling such systems. Experimental data analysed in the paper was collected in early 2012 during operation of a test solar drying facility in a sewage treatment plant in Błonie near Warsaw, Poland.

  11. Air sampling with solid phase microextraction

    NASA Astrophysics Data System (ADS)

    Martos, Perry Anthony

    There is an increasing need for simple yet accurate air sampling methods. The acceptance of new air sampling methods requires compatibility with conventional chromatographic equipment, and the new methods have to be environmentally friendly, simple to use, yet with equal, or better, detection limits, accuracy and precision than standard methods. Solid phase microextraction (SPME) satisfies the conditions for new air sampling methods. Analyte detection limits, accuracy and precision of analysis with SPME are typically better than with any conventional air sampling methods. Yet, air sampling with SPME requires no pumps, solvents, is re-usable, extremely simple to use, is completely compatible with current chromatographic equipment, and requires a small capital investment. The first SPME fiber coating used in this study was poly(dimethylsiloxane) (PDMS), a hydrophobic liquid film, to sample a large range of airborne hydrocarbons such as benzene and octane. Quantification without an external calibration procedure is possible with this coating. Well understood are the physical and chemical properties of this coating, which are quite similar to those of the siloxane stationary phase used in capillary columns. The log of analyte distribution coefficients for PDMS are linearly related to chromatographic retention indices and to the inverse of temperature. Therefore, the actual chromatogram from the analysis of the PDMS air sampler will yield the calibration parameters which are used to quantify unknown airborne analyte concentrations (ppb v to ppm v range). The second fiber coating used in this study was PDMS/divinyl benzene (PDMS/DVB) onto which o-(2,3,4,5,6- pentafluorobenzyl) hydroxylamine (PFBHA) was adsorbed for the on-fiber derivatization of gaseous formaldehyde (ppb v range), with and without external calibration. The oxime formed from the reaction can be detected with conventional gas chromatographic detectors. Typical grab sampling times were as small as 5 seconds

  12. East Mountain Area 1995 air sampling results

    SciTech Connect

    Deola, R.A.

    1996-09-01

    Ambient air samples were taken at two locations in the East Mountain Area in conjunction with thermal testing at the Lurance Canyon Burn Site (LCBS). The samples were taken to provide measurements of particulate matter with a diameter less than or equal to 10 micrometers (PM{sub 10}) and volatile organic compounds (VOCs). This report summarizes the results of the sampling performed in 1995. The results from small-scale testing performed to determine the potentially produced air pollutants in the thermal tests are included in this report. Analytical results indicate few samples produced measurable concentrations of pollutants believed to be produced by thermal testing. Recommendations for future air sampling in the East Mountain Area are also noted.

  13. Removing particulates from aspiration air during coke dry quenching

    SciTech Connect

    Stefanenko, V.T.; Lysenko, T.v.; Voronkova, T.I.; Gracheva, O.L.

    1983-01-01

    The characteristics of recovery of coke dust are due to the relatively large size of the particles and their highly abrasive nature. The use of wet dust traps is not feasible due to the difficulties arising from the necessity of treating the sludge water. It is feasible to use dry methods of purifying the aspiration air. As dust traps one may recommend type SDK-TsN-33 or SK-TsN-34 conical cyclones, as well as vertical electrofilters.

  14. 72. BUILDING NO. 555, AIR DRY HOUSE FOR DOUBLE BASE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    72. BUILDING NO. 555, AIR DRY HOUSE FOR DOUBLE BASE RIFLE AND CANNON POWDERS, LOOKING SOUTHWEST AT NORTH CORNER. 3 FT. GUAGE RAILROAD TRACK IN FOREGROUND. WOODEN RAILS SUBSTITUTED FOR STEEL RAILS FOR TRACKS ENTERING BUILDING TO PREVENT SPARKING. EXPLOSION-PROOF LIGHTING MOUNTED ON BUILDING EXTERIOR. - Picatinny Arsenal, 500 Area, Powder Factory & Power House, State Route 15 near I-80, Dover, Morris County, NJ

  15. 71. BUILDING NO. 555, AIR DRY HOUSE FOR DOUBLE BASE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    71. BUILDING NO. 555, AIR DRY HOUSE FOR DOUBLE BASE RIFLE AND CANNON POWDERS, LOOKING SOUTH AT NORTH CORNER, WITH DRAIN BOX FROM BUILDING FLOOR DRAIN IN FOREGROUND. TROUGH IS LEAD-LINED. BOX PRESUMABLY SETTLED OUT ANY NITRO-COTTON OR POWDER FROM WASTE WATER FROM RECOVERY PURPOSES. - Picatinny Arsenal, 500 Area, Powder Factory & Power House, State Route 15 near I-80, Dover, Morris County, NJ

  16. AIR DRYING AND PRETREATMENT EFFECTS ON SOIL SULFATE SORPTION

    EPA Science Inventory

    Drying, freezing, and refrigeration are commonly employed to facilitate the handling and storage of soil samples on which chemical, biological and physical analyses are to be performed. hese laboratory protocol have the potential to alter soil chemical characteristics and may res...

  17. Characterization of Dry-Air Aged Granules of Silver-Functionalized Silica Aerogel

    SciTech Connect

    Matyas, Josef; Fryxell, Glen E.; Robinson, Matthew J.

    2012-09-01

    This is a letter report to complete level 3 milestone "Assess aging characteristics of silica aerogels" for DOE FCRD program. Recently, samples of Ag0-functionalized silica aerogel were aged in flowing dry air for up to 6 months and then loaded with iodine. This dry-air aging simulated the impact of long-term exposure to process gases during process idling. The 6-month aged sample exhibited an iodine sorption capacity of 32 mass%, which was 9 mass % lower than that for an un-aged Ag0-functionalized silica aerogel. In an attempt to understand this decrease in sorption capacity, we characterized physical properties of the aged samples with Brunauer-Emmett-Teller (BET) nitrogen adsorption, X-ray diffraction (XRD), and high resolution scanning electron microscopy (SEM). The results showed no impact of aging on the aerogel microstructure or the silver nanoparticles in the aerogel, including their spatial distribution and morphology.

  18. Evaluating Radionuclide Air Emission Stack Sampling Systems

    SciTech Connect

    Ballinger, Marcel Y.

    2002-12-16

    The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R&D) facilities for the U.S. Department of Energy at the Hanford Site, Washington. These facilities are subject to Clean Air Act regulations that require sampling of radionuclide air emissions from some of these facilities. A revision to an American National Standards Institute (ANSI) standard on sampling radioactive air emissions has recently been incorporated into federal and state regulations and a re-evaluation of affected facilities is being performed to determine the impact. The revised standard requires a well-mixed sampling location that must be demonstrated through tests specified in the standard. It also carries a number of maintenance requirements, including inspections and cleaning of the sampling system. Evaluations were performed in 2000 – 2002 on two PNNL facilities to determine the operational and design impacts of the new requirements. The evaluation included inspection and cleaning maintenance activities plus testing to determine if the current sampling locations meet criteria in the revised standard. Results show a wide range of complexity in inspection and cleaning activities depending on accessibility of the system, ease of removal, and potential impact on building operations (need for outages). As expected, these High Efficiency Particulate Air (HEPA)-filtered systems did not show deposition significant enough to cause concerns with blocking of the nozzle or other parts of the system. The tests for sampling system location in the revised standard also varied in complexity depending on accessibility of the sample site and use of a scale model can alleviate many issues. Previous criteria to locate sampling systems at eight duct diameters downstream and two duct diameters upstream of the nearest disturbances is no guarantee of meeting criteria in the revised standard. A computational fluid dynamics model was helpful in understanding flow and

  19. Combination syringe provides air-free blood samples

    NASA Technical Reports Server (NTRS)

    Pool, S. L.

    1970-01-01

    Standard syringe and spinal needle are combined in unique manner to secure air-free blood samples. Combination syringe obtains air free samples because air bubbles become insignificant when samples greater than 1 cc are drawn.

  20. A microfluidic device for dry sample preservation in remote settings.

    PubMed

    Begolo, Stefano; Shen, Feng; Ismagilov, Rustem F

    2013-11-21

    This paper describes a microfluidic device for dry preservation of biological specimens at room temperature that incorporates chemical stabilization matrices. Long-term stabilization of samples is crucial for remote medical analysis, biosurveillance, and archiving, but the current paradigm for transporting remotely obtained samples relies on the costly "cold chain" to preserve analytes within biospecimens. We propose an alternative approach that involves the use of microfluidics to preserve samples in the dry state with stabilization matrices, developed by others, that are based on self-preservation chemistries found in nature. We describe a SlipChip-based device that allows minimally trained users to preserve samples with the three simple steps of placing a sample at an inlet, closing a lid, and slipping one layer of the device. The device fills automatically, and a pre-loaded desiccant dries the samples. Later, specimens can be rehydrated and recovered for analysis in a laboratory. This device is portable, compact, and self-contained, so it can be transported and operated by untrained users even in limited-resource settings. Features such as dead-end and sequential filling, combined with a "pumping lid" mechanism, enable precise quantification of the original sample's volume while avoiding overfilling. In addition, we demonstrated that the device can be integrated with a plasma filtration module, and we validated device operations and capabilities by testing the stability of purified RNA solutions. These features and the modularity of this platform (which facilitates integration and simplifies operation) would be applicable to other microfluidic devices beyond this application. We envision that as the field of stabilization matrices develops, microfluidic devices will be useful for cost-effectively facilitating remote analysis and biosurveillance while also opening new opportunities for diagnostics, drug development, and other medical fields. PMID:24056744

  1. Tetrachloroethene air pollution originating from coin-operated dry cleaning establishments.

    PubMed

    Gulyas, H; Hemmerling, L

    1990-10-01

    In 15 coin-operated dry cleaning establishments (CODC), in one building where a CODC had been run and in a private car transporting a dry-cleaned down jacket tetrachloroethene (TCE) indoor concentrations were investigated by air sampling with activated carbon tubes, elution of the carbon with toluene, and subsequent gas chromatographic analysis of the eluate. TCE concentrations in the car transporting the garment were up to 24.8 mg/m3. Within CODC air concentrations between 3.1 and 331 mg/m3 were measured. In the building where a CODC had once been run the TCE concentrations were slowly decreasing after removal of dry cleaning machines. In the basement below the CODC the TCE air concentration was 155 mg/m3 immediately after removal of the machines and 4.5 mg/m3 7.5 months later. TCE migrated from the basement via the staircase to the flats of the second floor where TCE air concentrations were about 1% of the concentrations in the basement. TCE-contaminated building material is shown to be a reservoir causing increased TCE air concentrations for a long time, which is serious considering the carcinogenic and reproductive risks from TCE exposure. PMID:2226380

  2. Tetrachloroethene air pollution originating from coin-operated dry cleaning establishments

    SciTech Connect

    Gulyas, H.; Hemmerling, L. )

    1990-10-01

    In 15 coin-operated dry cleaning establishments (CODC), in one building where a CODC had been run and in a private car transporting a dry-cleaned down jacket tetrachloroethene (TCE) indoor concentrations were investigated by air sampling with activated carbon tubes, elution of the carbon with toluene, and subsequent gas chromatographic analysis of the eluate. TCE concentrations in the car transporting the garment were up to 24.8 mg/m3. Within CODC air concentrations between 3.1 and 331 mg/m3 were measured. In the building where a CODC had once been run the TCE concentrations were slowly decreasing after removal of dry cleaning machines. In the basement below the CODC the TCE air concentration was 155 mg/m3 immediately after removal of the machines and 4.5 mg/m3 7.5 months later. TCE migrated from the basement via the staircase to the flats of the second floor where TCE air concentrations were about 1% of the concentrations in the basement. TCE-contaminated building material is shown to be a reservoir causing increased TCE air concentrations for a long time, which is serious considering the carcinogenic and reproductive risks from TCE exposure.

  3. A Microfluidic Device for Dry Sample Preservation in Remote Settings

    PubMed Central

    Begolo, Stefano; Shen, Feng; Ismagilov, Rustem F.

    2013-01-01

    Summary This paper describes a microfluidic device for dry preservation of biological specimens at room temperature that incorporates chemical stabilization matrices. Long-term stabilization of samples is crucial for remote medical analysis, biosurveillance, and archiving, but the current paradigm for transporting remotely obtained samples relies on the costly “cold chain” to preserve analytes within biospecimens. We propose an alternative approach that involves the use of microfluidics to preserve samples in the dry state with stabilization matrices, developed by others, that are based on self-preservation chemistries found in nature. We describe a SlipChip-based device that allows minimally trained users to preserve samples with the three simple steps of placing a sample at an inlet, closing a lid, and slipping one layer of the device. The device fills automatically, and a pre-loaded desiccant dries the samples. Later, specimens can be rehydrated and recovered for analysis in a laboratory. This device is portable, compact, and self-contained, so it can be transported and operated by untrained users even in limited-resource settings. Features such as dead-end and sequential filling, combined with a “pumping lid” mechanism, enable precise quantification of the original sample’s volume while avoiding overfilling. In addition, we demonstrated that the device can be integrated with a plasma filtration module, and we validated device operations and capabilities by testing the stability of purified RNA solutions. These features and the modularity of this platform (which facilitates integration and simplifies operation) would be applicable to other microfluidic devices beyond this application. We envision that as the field of stabilization matrices develops, microfluidic devices will be useful for cost-effectively facilitating remote analysis and biosurveillance while also opening new opportunities for diagnostics, drug development, and other medical fields

  4. Minimization of moisture readsorption in dried coal samples

    SciTech Connect

    Karthikeyan, M.

    2008-07-01

    Low-rank coals constitute a major energy source for the future as reserves of such high-moisture coals around the world are vast. Currently they are considered undesirable since high moisture content entails high transportation costs, potential safety hazards in transportation and storage, and the low thermal efficiency obtained in combustion of such coals. Furthermore, low-moisture-content coal is needed for the various coal pyrolysis and gasification processes. Hence, various upgrading processes have been developed to reduce the moisture content. Moisture readsorption and spontaneous combustion are important issues in coal upgrading processes. This article discusses results of laboratory experiments conducted to study the options for minimization of readsorption of moisture after drying of selected coal samples. Results suggest that there is little benefit in drying low-rank coal at high temperatures. It was found that the higher the amount of bitumen used for coating, the lower is the readsorption of moisture by dried coal. Also, mixing high-temperature-dried coal with wet coal in appropriate proportion can yield reduced moisture content as the sensible heat in the hot coal is utilized for evaporation.

  5. Entrainment of Upper Level Dry Air into Hurricane Earl

    NASA Technical Reports Server (NTRS)

    Guillory, Anthony R.; Jedlovee, Gary J.; Hood, Robbie E.; Atkinson, Robert J.; LaFontaine, Frank J.

    2000-01-01

    Hurricane Earl developed from a tropical wave that moved into the Gulf of Mexico, which triggered abundant convection. On 1 Sept. 1998, the wave was upgraded directly to a tropical storm. Earl reached hurricane status the next morning. The system moved erratically as it interacted with an upper level short wave trough rotating around a long wave trough to the northeast. The storm made landfall near 0600 UTC on 3 September near Panama City, FL. During August and September 1998, NASA conducted the Third Convection and Moisture Experiment (CAMEX-3). It focused on studying the intensity, track, and impacts at landfall of hurricanes. On the afternoon of 2 September 1998, the NASA ER2 high-altitude aircraft flying at 65,000 feet in tandem with the NASA DC-8 flying at 35,000 feet flew over and through, respectively, the eastern rainbands of Earl near the Florida Panhandle as the storm neared landfall in the region. Two approaches to studying Earl are undertaken here: first, an examination of the source and height of the dry air region using GOES-8 water vapor data and, second, a look into the impact of the dry air entrainment on the system using aircraft remote sensing data.

  6. Drying oven with heat reclamation and air pollution control system

    SciTech Connect

    Jamaluddin, A.A.

    1980-12-23

    A system of drying ovens is disclosed with associated means for heat reclamation and air pollution control. The ovens are primarily for drying or baking paint or other coatings on pipes or the like where the emissions are primarily hydrocarbons. In this system of ovens, hydrocarbon fumes are concentrated at the ends of the oven. Solvent laden fumes are, therefore, collected where the concentration is the highest. The exhaust from the oven is located at the central portion and leads to a combustion/incineration chamber where it is exhausted to atmosphere after incineration and a major part of the heat is recovered and recirculated to the oven. In a sequence of ovens, the exhaust from one oven is circulated to the next at a high linear velocity, but low volume (At 25% lel) and heated to a high temperature (1400/sup 0/F.) by in-line incineration of the fumes. The low volume, high velocity, high temperature gasses are mixed with a high volume, low velocity, low temperature exhaust collected from the end of that oven. This incineration and mixing and recirculation of gasses is repeated in each succeeding oven and no gasses are exhausted to atmosphere until the last oven. In the last oven, in sequence, a burner is provided to incinerate fumes recirculated at one end of the oven and the exhaust goes to atmosphere through an incinerator/heat exchanger where the reclaimed heat is supplied to outside air being fed to support combustion in the incinerator at one end of the last oven.

  7. Air Sampling Instruments for Evaluation of Atmospheric Contaminants. Fourth Edition.

    ERIC Educational Resources Information Center

    American Conference of Governmental Industrial Hygienists, Cincinnati, OH.

    This text, a revision and extension of the first three editions, consists of papers discussing the basic considerations in sampling air for specific purposes, sampler calibration, systems components, sample collectors, and descriptions of air-sampling instruments. (BT)

  8. Entrainment of Upper Level Dry Air Into Hurricane Earl

    NASA Technical Reports Server (NTRS)

    Guillory, Anthony R.; Jedlovec, Gary J.; Hood, Robbie E.; Atkinson, Robert J.; LaFontaine, Frank J.

    1999-01-01

    Hurricane Earl formed in the Gulf of Mexico in September 1998. It quickly was upgraded from a tropical disturbance to tropical storm status and then to a hurricane. Earl possessed hybrid (tropical and extratropical) characteristics throughout its lifetime. The system maintained and erratic track, which led to wide variability in the operational track forecasts. It eventually made landfall on the Florida panhandle on 2 September and raced northeastward. During August and September 1998, NASA conducted the third Convection and Moisture Experiment (CAMEX-3). The experiment was focused on studying hurricanes with an emphasis toward developing a better understanding of their intensification and motion. Earl provides a unique opportunity to utilize high spatial and temporal resolution data collected from the DC-8 and high altitude ER-2 NASA platforms, which flew over Earl as it made landfall. These data can also be put into broader view provided by other instruments from the Geosynchronous Operational Environmental Satellites (GOES) and the Tropical Rainfall Measuring Mission (TRMM) satellites. Hurricane Earl was affected by entrainment of dry air from the northwest. Hurricane Isis was intensifying and approaching the Mexican Pacific coast with its associated outflow potentially affecting the inflow into Earl as the storm neared Florida. In addition, a longwave synoptic trough circulation was present over the eastern U.S. Either or both of these could be responsible for the dry air into the system. This paper will focus on identifying the source of the dry by using upper-level wind and moisture fields derived from the GOES 6.7 um water vapor imagery. We will attempt to relate the large-scale observations to those from the NASA aircraft. An infrared instrument onboard the ER-2 also has a similar wavelength and may be able to confirm some of the GOES findings. In addition, a microwave radiometer with 4 channels focused on measuring precipitation and its associated ice

  9. Influence of drying air parameters on mass transfer characteristics of apple slices

    NASA Astrophysics Data System (ADS)

    Beigi, Mohsen

    2015-12-01

    To efficiently design both new drying process and equipment and/or to improve the existing systems, accurate values of mass transfer characteristics are necessary. The present study aimed to investigate the influence of drying air parameters (i.e. temperature, velocity and relative humidity) on effective diffusivity and convective mass transfer coefficient of apple slices. The Dincer and Dost model was used to determine the mass transfer characteristics. The obtained Biot number indicated that the moisture transfer in the apple slices was controlled by both internal and external resistance. The effective diffusivity and mass transfer coefficient values obtained to be in the ranges of 7.13 × 10-11-7.66 × 10-10 and 1.46 × 10-7-3.39 × 10-7 m s-1, respectively and the both of them increased with increasing drying air temperature and velocity, and decreasing relative humidity. The validation of the model showed that the model predicted the experimental drying curves of the samples with a good accuracy.

  10. Effects of Air Drying on Soil Available Phosphorus in Two Grassland Soils

    NASA Astrophysics Data System (ADS)

    Schaerer, M.; Frossard, E.; Sinaj, S.

    2003-04-01

    Mobilization of P from the soil to ground and surface water is principally determined by the amount of P in the soil and physico-chemical as well as biological processes determining the available P-pool that is in equilibrium with soil solution. Soil available P is commonly estimated on air dry soil using a variety of methods (extraction with water, dilute acids and bases, anion exchange resin, isotopic exchange or infinite sinks). Recently, attempts have been made to use these measurements to define the potential for transport of P from soil to water by overland flow or subsurface flow. The effect of air drying on soil properties in general, and plant nutrient status in particular, have been subject of a number of studies. The main objective of this paper was to evaluate the effect of air-drying on soil properties and available P. For this experiment, grassland soils were sampled on two study sites located on slopes in the watershed of Lake Greifensee, 25 km south-east of Zurich. Both soils (0-4 cm depth) are rich in P with 1.7 and 1.3 g kg-1 total P at site I and site II, respectively. The concentrations on isotopically exchangeable P within 1 minute (E1min, readily available P) for the same depth were also very high, 58 and 27 mg P kg soil-1 for the site I and II, respectively. In the present study both field moist and air dried soil samples were analyzed for microbial P (Pmic), resin extractable P (P_r), isotopically exchangeable P (E1min) and amorphous Al and Fe (Alox, Feox). Generally, the microbial P in field moist soils reached values up to 120 mg P/kg soil, whereas after drying they decreased by 73% in average for both soils. On the contrary to Pmic, available P estimated by different methods strongly increased after drying of the soil samples. The concentration of phosphate ions in the soil solution c_p, E1min and P_r were 4.2, 2.2 and 2 times higher in dry soils than in field moist soils. The increase in available P shows significant semilogarithmic

  11. How does mid-tropospheric dry air affect the evolution of supercellular convection?

    NASA Astrophysics Data System (ADS)

    Honda, Takumi; Kawano, Tetsuya

    2015-04-01

    To investigate the influence of mid-tropospheric dry air on the evolution of supercell storms, idealized numerical experiments with several moisture profiles were performed. In an environment with (without) a mid-level dry layer, supercellular convection decays immediately (persists for a long period). A set of trajectory analyses revealed that two suppression processes contribute to the convection decay in the environment with the mid-tropospheric dry layer. One is the entrainment process within the mid-tropospheric dry layer, and the other is the dry-air penetration process. In the latter process, dry air penetrates into the low-level updraft region, so that the supply of warm, moist air for convection is reduced. Neither of the processes contributes effectively in an environment with a dry layer located at a higher altitude. The dependence of the results on the environmental shear profile, evaporation rate, and the amount of convective available potential energy (CAPE) was also examined by additional experiments.

  12. Diagnosing AIRS Sampling with CloudSat Cloud Classes

    NASA Technical Reports Server (NTRS)

    Fetzer, Eric; Yue, Qing; Guillaume, Alexandre; Kahn, Brian

    2011-01-01

    AIRS yield and sampling vary with cloud state. Careful utilization of collocated multiple satellite sensors is necessary. Profile differences between AIRS and ECMWF model analyses indicate that AIRS has high sampling and excellent accuracy for certain meteorological conditions. Cloud-dependent sampling biases may have large impact on AIRS L2 and L3 data in climate research. MBL clouds / lower tropospheric stability relationship is one example. AIRS and CloudSat reveal a reasonable climatology in the MBL cloud regime despite limited sampling in stratocumulus. Thermodynamic parameters such as EIS derived from AIRS data map these cloud conditions successfully. We are working on characterizing AIRS scenes with mixed cloud types.

  13. A measurement of summertime dry deposition of ambient air particulates and associated metallic pollutants in Central Taiwan.

    PubMed

    Fang, Guor-Cheng; Chiang, Hung-Che; Chen, Yu-Cheng; Xiao, You-Fu; Wu, Chia-Ming; Kuo, Yu-Chen

    2015-04-01

    The purpose of this study is to characterize metallic elements associated with atmospheric particulate matter in the dry deposition plate, total suspended particulate, fine particles, and coarse particles at Taichung Harbor and Gong Ming Junior High School (airport) in central Taiwan at a sampling site from June 2013 to August 2013. The results indicated that: (1) the average concentrations of the metallic elements Cr and Cd were highest at the Gong Ming Junior High School (airport), and the average concentrations of the metallic elements Ni, Cu, and Pb were highest at the Taichung Harbor sampling site. (2) The high smelting industry density and export/import rate of heavily loaded cargos were the main reasons leading to these findings. (3) The average metallic element dry deposition and metallic element PM(2.5-10) all followed the order of Pb > Cr > Cu > Ni > Cd at the two sampling sites. However, the average metallic elements Cu and Pb were found to have the highest dry deposition velocities and concentrations in PM(2.5) for the two sampling sites in this study. (4) The correlation coefficients of ambient air particle dry deposition and concentration with wind speed at the airport were higher than those from the harbor sampling site. The wind and broad open spaces at Taichung Airport were the possible reasons for the increasing correlation coefficients for ambient air particle concentration and dry deposition with wind speed at the Taichung Airport sampling site. PMID:25185928

  14. SAMPLING FOR ORGANIC CHEMICALS IN AIR

    EPA Science Inventory

    Organic chemicals by far account for the majority of pollutants found in air. ore than 90% of the 75,000 chemicals listed in EPA's Toxic Substances Control Act Chemical Substance Inventory and 88% of the 189 Hazardous Air Pollutants (HAPS) named in the Clean Air Act Amendments of...

  15. Spontaneous Rayleigh-Brillouin scattering of ultraviolet light in nitrogen, dry air, and moist air.

    PubMed

    Witschas, Benjamin; Vieitez, Maria O; van Duijn, Eric-Jan; Reitebuch, Oliver; van de Water, Willem; Ubachs, Wim

    2010-08-01

    Atmospheric lidar techniques for the measurement of wind, temperature, and optical properties of aerosols rely on the exact knowledge of the spectral line shape of the scattered laser light on molecules. We report on spontaneous Rayleigh-Brillouin scattering measurements in the ultraviolet at a scattering angle of 90 degrees on N(2) and on dry and moist air. The measured line shapes are compared to the Tenti S6 model, which is shown to describe the scattering line shapes in air at atmospheric pressures with small but significant deviations. We demonstrate that the line profiles of N(2) and air under equal pressure and temperature conditions differ significantly, and that this difference can be described by the S6 model. Moreover, we show that even a high water vapor content in air up to a volume fraction of 3.6vol.% has no influence on the line shape of the scattered light. The results are of relevance for the future spaceborne lidars on ADM-Aeolus (Atmospheric Dynamics Mission) and EarthCARE (Earth Clouds, Aerosols, and Radiation Explorer). PMID:20676176

  16. Sampling for Beryllium Surface Contamination using Wet, Dry and Alcohol Wipe Sampling

    SciTech Connect

    Kerr, Kent

    2004-12-17

    This research project was conducted at the National Nuclear Security Administration's Kansas City Plant, operated by Honeywell Federal Manufacturing and Technologies, in conjunction with the Safety Sciences Department of Central Missouri State University, to compare relative removal efficiencies of three wipe sampling techniques currently used at Department of Energy facilities. Efficiencies of removal of beryllium contamination from typical painted surfaces were tested by wipe sampling with dry Whatman 42 filter paper, with water-moistened (Ghost Wipe) materials, and by methanol-moistened wipes. Test plates were prepared using 100 mm X 15 mm Pyrex Petri dishes with interior surfaces spray painted with a bond coat primer. To achieve uniform deposition over the test plate surface, 10 ml aliquots of solution containing 1 beryllium and 0.1 ml of metal working fluid were transferred to the test plates and subsequently evaporated. Metal working fluid was added to simulate the slight oiliness common on surfaces in metal working shops where fugitive oil mist accumulates over time. Sixteen test plates for each wipe method (dry, water, and methanol) were processed and sampled using a modification of wiping patterns recommended by OSHA Method 125G. Laboratory and statistical analysis showed that methanol-moistened wipe sampling removed significantly more (about twice as much) beryllium/oil-film surface contamination as water-moistened wipes (p< 0.001), which removed significantly more (about twice as much) residue as dry wipes (p <0.001). Evidence for beryllium sensitization via skin exposure argues in favor of wipe sampling with wetting agents that provide enhanced residue removal efficiency.

  17. Dry Flowing Abrasive Decontamination Technique for Pipe Systems with Swirling Air Flow

    SciTech Connect

    Kameo, Yutaka; Nakashima, Mikio; Hirabayashi, Takakuni

    2003-10-15

    A dry abrasive decontamination method was developed for removing radioactive corrosion products from surfaces of coolant pipe systems in decommissioning of a nuclear power plant. Erosion behavior of inside surfaces of stainless and carbon steel pipes by a swirling air flow containing alumina or cast-iron grit abrasive was studied. Erosion depths of the test pipes were approximately proportional to an abrasive concentration in air and an exponent of flow rate of airstream. The experimental results indicated that the present method could keep satisfactory erosion ability of abrasives even for a large-size pipe. The present method was successfully applied to {sup 60}Co-contaminated specimens sampled from a pipe of the water cleanup system of the Japan Power Demonstration Reactor.

  18. Influence of power ultrasound application on mass transport and microstructure of orange peel during hot air drying

    NASA Astrophysics Data System (ADS)

    Ortuño, Carmen; Pérez-Munuera, Isabel; Puig, Ana; Riera, Enrique; Garcia-Perez, J. V.

    2010-01-01

    Power ultrasound application on convective drying of foodstuffs may be considered an emergent technology. This work deals with the influence of power ultrasound on drying of natural materials addressing the kinetic as well as the product's microstructure. Convective drying kinetics of orange peel slabs (thickness 5.95±0.41 mm) were carried out at 40 ∘C and 1 m/s with (US) and without (AIR) power ultrasound application. A diffusion model considering external resistance to mass transfer was considered to describe drying kinetics. Fresh, US and AIR dried samples were analyzed using Cryo-SEM. Results showed that drying kinetics of orange peel were significantly improved by the application of power ultrasound. From modeling, it was observed a significant (p¡0.05) increase in both mass transfer coefficient and effective moisture diffusivity. The effects on mass transfer properties were confirmed from microestructural observations. In the cuticle surface, the pores were obstructed by wax components scattering, which evidence the ultrasonic effects on the interfaces. The cells of the flavedo were compressed and large intercellular air spaces were generated in the albedo facilitating water transfer through it.

  19. Performance of Silica Gel in the Role of Residual Air Drying

    NASA Technical Reports Server (NTRS)

    Jan, Darrell L.; Hogan, John A.; Koss, Brian; Palmer, Gary H.; Richardson, Justine; Linggi, Paul

    2014-01-01

    Removal of carbon dioxide (CO2) is a necessary step in air revitalization and is often accomplished with sorbent materials. Since moisture competes with CO2 in sorbent materials, it is necessary to remove the water first. This is typically accomplished in two stages: bulk removal and residual drying. Silica gel is used as the bulk drying material in the Carbon Dioxide Removal Assembly (CDRA) in operation on ISS. There has been some speculation that silica gel may also be capable of serving as the residual drying material. This paper will describe test apparatus and procedures for determining the performance of silica gel in residual air drying.

  20. Reduced heat stress in offices in the tropics using solar powered drying of the supply air.

    PubMed

    Gunnarsen, L; Santos, A M B

    2002-12-01

    Many solutions to indoor climate problems known from developed countries may have prohibitive installation and running costs in developing countries. The purpose was to develop a low-cost solution to heat stress in a hot and humid environment based on solar powered drying of supply air. Dry supply air may facilitate personal cooling by increased evaporation of sweat. Heat acclimatized people with efficient sweating may in particular benefit from this cooling. A prototype solar powered supply system for dried-only air was made. Air from the system was mixed with room air, heated to six different combinations of temperature and humidity and led to Personal Units for Ventilation and Cooling (PUVAC) in six cubicles simulating office workplaces. A total of 123 heat acclimatized subjects were exposed 45 min in each of the cubicles. A model for the combined effect of operative temperature of room, moisture content of room air, temperature of supply air and moisture content of supply air was developed based on the experiments. Reduction of moisture content in the supply air by 1.6 g/kg had the same effect as lowering the operative temperature by 1 degree C. The solar-powered system for supplying dry air is a low-cost alternative to traditional air conditioning in hot and humid regions. PMID:12532757

  1. The Impact of Dry Midlevel Air on Hurricane Intensity in Idealized Simulations with No Mean Flow

    NASA Technical Reports Server (NTRS)

    Braun, Scott A.; Sippel, Jason A.; Nolan, David S.

    2012-01-01

    This study examines the potential negative influences of dry midlevel air on the development of tropical cyclones (specifically, its role in enhancing cold downdraft activity and suppressing storm development). The Weather Research and Forecasting model is used to construct two sets of idealized simulations of hurricane development in environments with different configurations of dry air. The first set of simulations begins with dry air located north of the vortex center by distances ranging from 0 to 270 km, whereas the second set of simulations begins with dry air completely surrounding the vortex, but with moist envelopes in the vortex core ranging in size from 0 to 150 km in radius. No impact of the dry air is seen for dry layers located more than 270 km north of the initial vortex center (approximately 3 times the initial radius of maximum wind). When the dry air is initially closer to the vortex center, it suppresses convective development where it entrains into the storm circulation, leading to increasingly asymmetric convection and slower storm development. The presence of dry air throughout the domain, including the vortex center, substantially slows storm development. However, the presence of a moist envelope around the vortex center eliminates the deleterious impact on storm intensity. Instead, storm size is significantly reduced. The simulations suggest that dry air slows intensification only when it is located very close to the vortex core at early times. When it does slow storm development, it does so primarily by inducing outward- moving convective asymmetries that temporarily shift latent heating radially outward away from the high-vorticity inner core.

  2. MEASUREMENT OF INDOOR AIR EMISSIONS FROM DRY-PROCESS PHOTOCOPY MACHINES

    EPA Science Inventory

    The article provides background information on indoor air emissions from office equipment, with emphasis on dry-process photocopy machines. The test method is described in detail along with results of a study to evaluate the test method using four dry-process photocopy machines. ...

  3. Drying of chilli in a combined infrared and hot air rotary dryer.

    PubMed

    Mihindukulasuriya, Suramya D F; Jayasuriya, Hemantha P W

    2015-08-01

    The investigation of an economical and efficient drying method for chilli is beneficial because it could provide a means of overcoming the drawbacks of traditional drying methods: high operating power and long drying time, which result in a decrease in the quality of the chilli. This study involved the design and development of a combined infrared and hot air laboratory-scale rotary dryer, which consists of three operating modes: hot air, infrared, and combined infrared and hot air. Drying experiments were conducted at five different temperatures (50, 55, 60, 65, and 70 °C). The drying behavior produced with the three operating modes was evaluated. The best mode was determined based on the parameters for evaluating the quality of chilli, the power consumption, and the retention time. The results indicate that the optimal overall drying performance for chilli was achieved at 70, 65, 50 °C drying temperatures in hot air, combined, and IR mode, respectively. A positive correlation was observed between retention time and power consumption with the hot air and the combined modes, while a negative correlation was identified in the IR mode. PMID:26243909

  4. A continuous sampling air-ICP for metals emission monitoring

    SciTech Connect

    Baldwin, D.P.; Zamzow, D.S.; Eckels, D.E.; Miller, G.P.

    1999-09-19

    An air-inductively coupled plasma (air-ICP) system has been developed for continuous sampling and monitoring of metals as a continuous emission monitor (CEM). The plasma is contained in a metal enclosure to allow reduced-pressure operation. The enclosure and plasma are operated at a pressure slightly less than atmospheric using a Roots blower, so that sample gas is continuously drawn into the plasma. A Teflon sampling chamber, equipped with a sampling pump, is connected to the stack that is to be monitored to isokinetically sample gas from the exhaust line and introduce the sample into the air-ICP. Optical emission from metals in the sampled gas stream is detected and monitored using an acousto-optic tunable filter (AOTF)--echelle spectrometer system. A description of the continuous sampling air-ICP system is given, along with some preliminary laboratory data for continuous monitoring of metals.

  5. Continuous sampling air-ICP for metals emission monitoring

    NASA Astrophysics Data System (ADS)

    Baldwin, David P.; Zamzow, Daniel S.; Eckels, David E.; Miller, George P.

    1999-12-01

    An air-inductively coupled plasma (air-ICP) system has been developed for continuous sampling and monitoring of metals as a continuous emission monitor (CEM). The plasma is contained in a metal enclosure to allow reduced-pressure operation. The enclosure and plasma are operated at a pressure slightly less than atmospheric using a Roots blower, so that sample gas is continuously drawn into the plasma. A Teflon sampling chamber, equipped with a sampling pump, is connected to the stack that is to be monitored to isokinetically sample gas from the exhaust line and introduce the sample into the air-ICP. Optical emission from metals in the sampled gas stream is detected and monitored using an acousto-optic tunable filter (AOTF)-echelle spectrometer system. A description of the continuous sampling air-ICP system is given, along with some preliminary laboratory data for continuous monitoring of metals.

  6. Energy analysis on use of air and superheated steam as drying media

    SciTech Connect

    Tarnawski, W.Z.; Mitera, J.; Borowski, P.; Klepaczka, A.

    1996-10-01

    The physical properties of air and superheated steam were analyzed in a range of temperatures applied in paper and paperboard drying processes. On the basis of tests carried out on a pilot stand the values of energy indices for air and steam drying processes are compared. With the drying media temperature as T{sub M} = 300 C, nozzle velocity {nu} = 60 m/s and using the Huang and Mujumdar model as well as relationships given by Chance a comparative analysis of the results has been carried out. Variation of several indices in the range of temperatures 100--600 C and various nozzle velocities was studied.

  7. Prediction efficiency by near-infrared spectroscopy of immunoglobulin G in liquid and dried bovine colostrum samples.

    PubMed

    Rivero, M Jordana; Alomar, Daniel; Valderrama, Ximena; Le Cozler, Yannick; Velásquez, Alejandro; Haines, Deborah

    2016-08-01

    The objective of this study was to compare the prediction efficiency of IgG concentration in bovine colostrum by NIRS, using liquid and dried (Dry-Extract Spectroscopy for Infrared Reflectance, DESIR) samples by transflectance and reflectance modes, respectively. Colostrum samples (157), obtained from 2 commercial Holstein dairy farms, were collected within the first hour after calving and kept at -20 °C until analysis. After thawing and homogenisation, a subsample of 500 mg of liquid colostrum was placed in an aluminium mirror transflectance cell (0·1 mm path length), in duplicate, to collect the spectrum. A glass fiber filter disc was infused with another subsample of 500 mg of colostrum, in duplicate, and dried in a forced-air oven at 60 °C for 20 min. The samples were placed in cells for dry samples to collect the spectra. The spectra in the VIS-NIR region (400-2500 nm) were obtained with a NIRSystems 6500 monochromator. Mathematical treatments, scatter correction treatments and number of cross-validation groups were tested to obtain prediction equations for both techniques. Reference analysis for IgG content was performed by radial immunodiffusion. The DESIR technique showed a higher variation in the spectral regions associated with water absorption bands, compared with liquid samples. The best equation for transflectance method (liquid samples) obtained a higher coefficient of determination for calibration (0·95 vs. 0·94, respectively) and cross validation (0·94 vs. 0·91, respectively), and a lower error of cross validation (9·03 vs. 11·5, respectively) than the best equation for reflectance method (DESIR samples). In final, both methods showed excellent capacity for quantitative analysis, with residual predictive deviations above 3. It is concluded that, regarding accuracy of prediction and time for obtaining results of IgG from bovine colostrum, NIRS analysis of liquid samples (transflectance) is recommended over dried samples (DESIR technique by

  8. Venturi Air-Jet Vacuum Ejector For Sampling Air

    NASA Technical Reports Server (NTRS)

    Hill, Gerald F.; Sachse, Glen W.; Burney, L. Garland; Wade, Larry O.

    1990-01-01

    Venturi air-jet vacuum ejector pump light in weight, requires no electrical power, does not contribute heat to aircraft, and provides high pumping speeds at moderate suctions. High-pressure motive gas required for this type of pump bled from compressor of aircraft engine with negligible effect on performance of engine. Used as source of vacuum for differential-absorption CO-measurement (DACOM), modified to achieve in situ measurements of CO at frequency response of 10 Hz. Provides improvement in spatial resolution and potentially leads to capability to measure turbulent flux of CO by use of eddy-correlation technique.

  9. Reaction rate constant for dry air oxidation of K Basin fuel

    SciTech Connect

    Trimble, D.J.

    1998-04-29

    The rate of oxidation of spent nuclear fuel stored in the K Basin water is an important parameter when assessing the processes and accident scenarios for preparing the fuel for dry storage. The literature provides data and rate laws for the oxidation of unirradiated uranium in various environments. Measurement data for the dry air oxidation of K Basin fuel is compared to the literature data for linear oxidation in dry air. Equations for the correlations and statistical bounds to the K Basin fuel data and the literature data are selected for predicting nominal and bounding rates for the dry air oxidation of the K Basin fuel. These rate equations are intended for use in the Spent Nuclear Fuel Project Technical Data book.

  10. The effect of air temperature on the sappan wood extract drying

    NASA Astrophysics Data System (ADS)

    Djaeni, M.; Triyastuti, M. S.; Asiah, N.; Annisa, A. N.; Novita, D. A.

    2015-12-01

    The sappan wood extract contain natural colour called brazilin that can be used as a food colouring and antioxidant. The product is commonly found as a dry extract powder for consummer convenience. The spray dryer with air dehumidification can be an option to retain the colour and antioxidant agent. This paper discusses the effect of air temperature on sappan wood extract drying that was mixed with maltodextrin. As responses, the particle size, final moisture content, and extract solubility degradation were observed. In all cases, the process conducted in temperature ranging 90 - 110°C can retain the brazilin quality as seen in solubility and particle size. In addition, the sappan wood extract can be fully dried with moisture content below 2%. Moreover, with the increase of air temperature, the particle size of dry extract can be smaller.

  11. Mathematical modelling of thin layer hot air drying of carrot pomace.

    PubMed

    Kumar, Navneet; Sarkar, B C; Sharma, H K

    2012-02-01

    Thin layer carrot pomace drying characteristics were evaluated in a laboratory scale hot air forced convective dryer. The drying experiments were carried out at 60, 65, 70 & 75 °C and at an air velocity of 0.7 m/s. Mathematical models were tested to fit drying data of carrot pomace. The whole drying process of carrot pomace took place in a falling rate period except a very short accelerating period at the beginning. The average values of effective diffusivity ranged from 2.74 × 10(-9) to 4.64 × 10(-9) m(2)/s for drying carrot pomace. The activation energy value was 23.05 kJ/mol for the whole falling rate period. PMID:23572823

  12. Retrofitting Air Conditioning and Duct Systems in Hot, Dry Climates

    SciTech Connect

    Shapiro, Carl; Aldrich, Robb; Arena, Lois

    2012-07-01

    This technical report describes CARB's work with Clark County Community Resources Division in Las Vegas, Nevada, to optimize procedures for upgrading cooling systems on existing homes in the area to implement health, safety, and energy improvements. Detailed monitoring of five AC systems showed that three of the five systems met or exceeded air flow rate goals.

  13. Comparison of metal lability in air-dried and fresh dewatered drinking water treatment residuals.

    PubMed

    Wang, Changhui; Pei, Yuansheng; Zhao, Yaqian

    2015-01-01

    In this work, the labilities of Al, As, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Mo, Ni, Pb, Sr, V and Zn in air-dried (for 60 days) and fresh dewatered WTRs were compared using the Toxicity Characteristic Leaching Procedure (TCLP), fractionation, in vitro digestion and a plant enrichment test. The results showed that the air-dried and fresh dewatered WTRs had different properties, e.g., organic matter composition and available nutrients. The air-dried and fresh dewatered WTRs were non-haf zardous according to the TCLP assessment method used in the United States; however, the metals in the two types of WTRs had different lability. Compared with the metals in the fresh dewatered WTRs, those in the air-dried WTRs tended to be in more stable fractions and also exhibited lower bioaccessibility and bioavailability. Therefore, air-drying can decrease the metal lability and thereby reduce the potential metal pollution risk of WTRs. PMID:25560259

  14. D-0 End Calorimeter Warm Tube/TeV Dry Air Purge

    SciTech Connect

    Leibfritz, J.R.; /Fermilab

    1991-08-14

    This Engineering Note studies the design of the Dry Air Purge that is going to flow through the Warm Tube of the End Calorimeter of the D-O Calorimeter. The Tev tubes through the E.C. can be thought of as a cluster of concentric tubes: The Tev tube, the warm (vacuum vessel) tube, 15 layers of superinsulation, the cold (argon vessel) tube, and the Inner Hadronic center support tube. The Dry Air Purge will involve flowing Dry Air through the annular region between the Warm Tube and the Tev Beam Pipe. This air flow is intended to prevent condensation from forming in this region which could turn to ice under cryogenic temperatures. Any ice formed in this gap, could cause serious problems when these tubes are moved. The Air will flow through a Nylon Tube Fitting -1/4-inch I.D. to 1/8-inch male pipe thread (Cole Palmer YB-06465-15) see Drawing MC-295221 (Appendix A). This fitting will be attached to the Nylon 2-inch Tube-Wiper and Seal Assembly which is clamped to the ends of the Warm Tube (Appendix A). This note includes drawings and calculations that explain the setup of the Dry Air Purge and give the required information on the pressure drops through the setup. The Equations and properties used in the calculations were obtained from the Applied Fluid Dynamics Handbook by Robert D. Blevins and Fluid Dynamics Second Edition by Frank M. White.

  15. APPLICATION OF SEMIPERMEABLE MEMBRANE DEVICES TO INDOOR AIR SAMPLING

    EPA Science Inventory

    Semipermeable membrane devices (SPMDs) are a relatively new passive sampling technique for nonpolar organic compounds that have been extensively used for surface water sampling. A small body of literature indicates that SPMDs are also useful for air sampling. Because SPMDs ha...

  16. Sampling of nitrates in ambient air

    NASA Astrophysics Data System (ADS)

    Appel, B. R.; Tokiwa, Y.; Haik, M.

    Methods for the measurement of nitric acid, particulate nitrate and total inorganic nitrate (i.e. HNO 3 plus particulate nitrate) are compared using atmospheric samples from the Los Angeles Basin. Nitric acid was measured by (1) the nitrate collected on nylon or NaCl-impregnated cellulose filters after removal of particulate matter with Teflon prefilters, (2) long-path Fourier transform infrared spectroscopy (FTIR) performed by a collaborating investigator, and (3) the difference between total inorganic nitrate (TIN) and particulate nitrate (PN). TIN was measured by the sum of the nitrate collected with a Teflon prefilter and nylon or NaCl-impregnated after-filter. PN was measured by the nitrate able to penetrate a diffusion dénuder coated to remove acidic gases (e.g. HNO 3). Losses of nitrate from Teflon prefilters were determined by comparing the nitrate retained by these filters to the nitrate penetrating the acid gas denuder. TIN and the nitrate collected with glass fiber filters were compared to assess the origin of the artifact particulate nitrate on the latter. Nitric acid measurements using nylon or NaCl-impregnated after-filters were substantially higher than those by the difference technique. This correlated with losses of nitrate from the Teflon prefilters, which exceeded 50 % at high ambient temperature and low relative humidity. Nitric acid by the difference method exceeded that by FTIR by, on average, 20 %. Thus errors inferred in HNO 3 measurements by comparison to the difference measurements are considered minimum values. The high values for HNO 3 by the difference method are consistent with the partial loss of PN in the acid gas denuder. However, no loss of 0.1 μm to 3 μm diameter NH 4NO 3 particles was observed. Thus, if significant, such loss is restricted to coarse particulate nitrate. Heating the filter samplers was shown to increase sampling errors. Nitrate results obtained in short-term, low volume sampling with Gelman A glass fiber

  17. EML Surface Air Sampling Program, 1990--1993 data

    SciTech Connect

    Larsen, R.J.; Sanderson, C.G.; Kada, J.

    1995-11-01

    Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory`s Surface Air Sampling Program (SASP) during 1990--1993, with the exception of April 1993, indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the sampling and analytical techniques that were used to collect and measure them. The occasional detection of {sup 137}Cs in some air filter samples may have resulted from resuspension of previously deposited debris. Following the April 6, 1993 accident and release of radionuclides into the atmosphere at a reprocessing plant in the Tomsk-7 military nuclear complex located 16 km north of the Siberian city of Tomsk, Russia, weekly air filter samples from Barrow, Alaska; Thule, Greenland and Moosonee, Canada were selected for special analyses. The naturally occurring radioisotopes that the authors measure, {sup 7}Be and {sup 210}Pb, continue to be detected in most air filter samples. Variations in the annual mean concentrations of {sup 7}Be at many of the sites appear to result primarily from changes in the atmospheric production rate of this cosmogenic radionuclide. Short-term variations in the concentrations of {sup 7}Be and {sup 210}Pb continued to be observed at many sites at which weekly air filter samples were analyzed. The monthly gross gamma-ray activity and the monthly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb measured at sampling sites in SASP during 1990--1993 are presented. The weekly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb for samples collected during 1990--1993 are given for 17 sites.

  18. Effects of Dry Air Intrusion on MJO Initiation during DYNAMO (Invited)

    NASA Astrophysics Data System (ADS)

    Chen, S. S.; Kerns, B. W.; Savarin, A.

    2013-12-01

    One of the challenging issues in MJO initiation over the equatorial Indian Ocean is interaction of convection and environmental moisture. It involves complex, multi-scale processes from entrainment/detrainment of cloud, convective downdraft and cold pools affecting the air-sea interface, to large-scale advection controlled by tropical and extratropical circulation. Observations from the DYNAMO field campaign in 2011 show that dry air intrusion into the equatorial Indian Ocean affects convection on both synoptic and MJO time scales. During mid-late November, a strong MJO event, refereed to as MJO2, developed over the DYNAMO array, which has the best coverage of the observational platforms including two aircraft, two research vessels, and island stations. This study focuses on two aspects of the dry air intrusion during MJO2: 1) convective cold pool structure and recovery related to convective-environmental moisture interaction, and 2) dry air intrusion and synoptic variability in convection/precipitation in MJO initiation. Convective downdraft can be affected by environmental water vapor due to entrainment by the convective clouds. Mid-level dry air observed during the convectively suppressed phase of MJO2 seems to enhance convective downdraft by increasing evaporation and, therefore, the strength of the downdraft and cold pools. We examine the convective cold pool structure and boundary layer recovery using the NOAA P-3 aircraft observations, include flight-level, Doppler radar, and GPS dropsonde data. The depth and strength of convective cold pools are defined by the negative buoyancy from the dropsonde data. Recovery of the cold pools in the boundary layer is determined by not only the strength and depth of the cold pools but also the air-sea heat and moisture fluxes. Given that the water vapor and surface winds are distinct for the convectively active and suppressed phases of MJO2, the aircraft data are stratified by the two different large-scale regimes of MJO2

  19. Nitrogen mineralization from anaerobically digested centrifuge cake and aged air-dried biosolids.

    PubMed

    Kumar, Kuldip; Hundal, Lakhwinder S; Cox, Albert E; Granato, Thomas

    2014-09-01

    This study was conducted to estimate nitrogen (N) mineralization of anaerobically digested centrifuge cake from the Stickney Water Reclamation Plant (SWRP) and Calumet Water Reclamation Plant (CWRP), lagoon-aged air-dried biosolids from the CWRP, and Milorganite at three rates of application (0, 12.5 and 25 Mg ha(-1)). The N mineralized varied among biosolids as follows: Milorganite (44%) > SWRP centrifuge cake (35%) > CWRP centrifuge cake (31%) > aged air-dried (13%). The N mineralized in the SWRP cake (32%) and CWRP aged air-dried biosolids (12%) determined from the 15N study were in agreement with the first study. The N mineralization value for centrifuge cake biosolids observed in our study is higher than the value given in the Part 503 rule and Illinois Part 391 guidelines. These results will be used to fine-tune biosolids application rate to match crop N demand without compromising yield while minimizing any adverse effect on the environment. PMID:25327023

  20. Estimation of whole lemon mass transfer parameters during hot air drying using different modelling methods

    NASA Astrophysics Data System (ADS)

    Torki-Harchegani, Mehdi; Ghanbarian, Davoud; Sadeghi, Morteza

    2015-08-01

    To design new dryers or improve existing drying equipments, accurate values of mass transfer parameters is of great importance. In this study, an experimental and theoretical investigation of drying whole lemons was carried out. The whole lemons were dried in a convective hot air dryer at different air temperatures (50, 60 and 75 °C) and a constant air velocity (1 m s-1). In theoretical consideration, three moisture transfer models including Dincer and Dost model, Bi- G correlation approach and conventional solution of Fick's second law of diffusion were used to determine moisture transfer parameters and predict dimensionless moisture content curves. The predicted results were then compared with the experimental data and the higher degree of prediction accuracy was achieved by the Dincer and Dost model.

  1. Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS

    NASA Astrophysics Data System (ADS)

    Chambers, Andrew G.; Percy, Andrew J.; Hardie, Darryl B.; Borchers, Christoph H.

    2013-09-01

    Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.

  2. Mathematical modelling of thin layer hot air drying of apricot with combined heat and power dryer.

    PubMed

    Faal, Saeed; Tavakoli, Teymor; Ghobadian, Barat

    2015-05-01

    In this study thermal energy of an engine was used to dry apricot. For this purpose, experiments were conducted on thin layer drying apricot with combined heat and power dryer, in a laboratory dryer. The drying experiments were carried out for four levels of engine output power (25 %, 50 %, 75 % and full load), producing temperatures of 50, 60, 70, and 80 ° C in drying chamber respectively. The air velocity in drying chamber was about 0.5 ± 0.05 m/s. Different mathematical models were evaluated to predict the behavior of apricot drying in a combined heat and power dryer. Conventional statistical equations namely modeling efficiency (EF), Root mean square error (RMSE) and chi-square (χ2) were also used to determine the most suitable model. Assessments indicated that the Logarithmic model considering the values of EF = 0.998746, χ 2 = 0.000120 and RMSE = 0.004772, shows the best treatment of drying apricot with combined heat and power dryer among eleven models were used in this study. The average values of effective diffusivity ranged 1.6260 × 10(-9) to 4.3612 × 10(-9) m2/s for drying apricot at air temperatures between 50 and 80 °C and at the air flow rate of 0.5 ± 0.05 m/s; the values of Deff increased with the increase of drying temperature the effective diffusivities in the second falling rate period were about eight times greater than that in the first falling rate period. PMID:25892795

  3. Solid waste transuranic storage and assay facility indoor air sampling

    SciTech Connect

    Pingel, L.A., Westinghouse Hanford

    1996-08-20

    The purpose of the study is to collect and analyze samples of the indoor air at the Transuranic Storage and Assay Facility (TRUSAF), Westinghouse Hanford. A modified US EPA TO-14 methodology, using gas chromatography/mass spectrography, may be used for the collection and analysis of the samples. The information obtained will be used to estimate the total release of volatile organic compounds from TRUSAF to determine the need for air emmission permits.

  4. Efficiency of dust sampling inlets in calm air.

    PubMed

    Breslin, J A; Stein, R L

    1975-08-01

    Measurement of airborne dust concentrations usually involves drawing a sample of the dust-laden air into the measuring instrument through an inlet. Even if the surrounding air is calm, theoretical calculations predict that large particles may not be sampled accurately due to the combined effects of gravity and inertia on the particles near the sampling inlet. Tests were conducted to determine the conditions of particle size, inlet radius, and flow rare necessary for accurate dust sampling. A coal-dust aerosol was sampled simultaneously through inlets of different diameters at the same volume flow-rate and collected on filters. The dust was removed from the filters and the particles were counted and sized with a Coulter counter. Results showed that published criteria for inlet conditions for correct sampling are overly restrictive and that respirable-size particles are sampled correctly in the normal range or operation of most dust sampling instruments. PMID:1227283

  5. METHODS TO SAMPLE AIR BORNE PROPAGULES OF ASPERGILLUS FLAVUS

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Several techniques (cyclone samplers, filter samplers and rotorods) were evaluated for detection of airborne Aspergillus flavus Link propagules in a cultivated region of southwest Arizona. Cyclone samplers operated continuously for 168 h (7 d) collected a dry sample that was ideal for quantificatio...

  6. Concepts for Environmental Radioactive Air Sampling and Monitoring

    SciTech Connect

    Barnett, J. Matthew

    2011-11-04

    Environmental radioactive air sampling and monitoring is becoming increasingly important as regulatory agencies promulgate requirements for the measurement and quantification of radioactive contaminants. While researchers add to the growing body of knowledge in this area, events such as earthquakes and tsunamis demonstrate how nuclear systems can be compromised. The result is the need for adequate environmental monitoring to assure the public of their safety and to assist emergency workers in their response. Two forms of radioactive air monitoring include direct effluent measurements and environmental surveillance. This chapter presents basic concepts for direct effluent sampling and environmental surveillance of radioactive air emissions, including information on establishing the basis for sampling and/or monitoring, criteria for sampling media and sample analysis, reporting and compliance, and continual improvement.

  7. Thin layer convective air drying of wild edible plant (Allium roseum) leaves: experimental kinetics, modeling and quality.

    PubMed

    Ben Haj Said, Leila; Najjaa, Hanen; Farhat, Abdelhamid; Neffati, Mohamed; Bellagha, Sihem

    2015-06-01

    The present study deals with the valorization of an edible spontaneous plant of the Tunisian arid areas: Allium roseum. This plant is traditionally used for therapeutic and culinary uses. Thin-layer drying behavior of Allium roseum leaves was investigated at 40, 50 and 60 °C drying air temperatures and 1 and l.5 m/s air velocity, in a convective dryer. The increase in air temperature significantly affected the moisture loss and reduced the drying time while air velocity was an insignificant factor during drying of Allium roseum leaves. Five models selected from the literature were found to satisfactorily describe drying kinetics of Allium roseum leaves for all tested drying conditions. Drying data were analyzed to obtain moisture diffusivity values. During the falling rate-drying period, moisture transfer from Allium roseum leaves was described by applying the Fick's diffusion model. Moisture diffusivity varied from 2.55 × 10(-12) to 8.83 × 10(-12) m(2)/s and increased with air temperature. Activation energy during convective drying was calculated using an exponential expression based on Arrhenius equation and ranged between 46.80 and 52.68 kJ/mol. All sulfur compounds detected in the fresh leaves were detected in the dried leaves. Convective air drying preserved the sulfur compounds potential formation. PMID:26028758

  8. Dry purification of aspirational air in coke-sorting systems with wet slaking of coke

    SciTech Connect

    T.F. Trembach; A.G. Klimenko

    2009-07-15

    Coke transportation after wet slaking is accompanied by the release of dust in the production building and in the surrounding atmosphere. Wet methods are traditionally used to purify very humid air. Giprokoks has developed designs for highly efficient dry dust-removal methods in such conditions.

  9. Effect of heterogenous and homogenous air gaps on dry heat loss through the garment

    NASA Astrophysics Data System (ADS)

    Mert, Emel; Psikuta, Agnes; Bueno, Marie-Ange; Rossi, René M.

    2015-11-01

    In real life conditions, the trapped air between the human body and the garment has uneven shape and vary over the body parts as a consequence of the complex geometry of the human body. However, the existing clothing models assume uniform air layer between the human body and the garment or its full contact, which may cause large error in the output of simulations. Therefore, the aim of this study was to investigate the effect of a heterogeneous vertical air gap with different configuration of folds (size and frequency) on dry heat loss using a heated cylinder (Torso). It was found that the presence of folds in the garment led to an increased heat loss from the body in comparison to a homogeneous air gap of comparable size. Interestingly, the size of folds did not have an influence on the dry heat loss. Additionally, the effect of the contact area on dry heat loss became important when exceeding a threshold of about 42 %. The results from this study are useful for modelling of a realistic dry heat loss through the clothing and contribute to the improvement of design of protective and active sport garments.

  10. Combustion Gas Properties I-ASTM Jet a Fuel and Dry Air

    NASA Technical Reports Server (NTRS)

    Jones, R. E.; Trout, A. M.; Wear, J. D.; Mcbride, B. J.

    1984-01-01

    A series of computations was made to produce the equilibrium temperature and gas composition for ASTM jet A fuel and dry air. The computed tables and figures provide combustion gas property data for pressures from 0.5 to 50 atmospheres and equivalence ratios from 0 to 2.0.

  11. EVALUATION OF A TEST METHOD FOR MEASURING INDOOR AIR EMISSIONS FROM DRY-PROCESS PHOTOCOPIERS

    EPA Science Inventory

    A large chamber test method for measuring indoor air emissions from office equipment was developed, evaluated, and revised based on the initial testing of four dry-process photocopiers. Because all chambers may not necessarily produce similar results (e.g., due to differences in ...

  12. Effect of heterogenous and homogenous air gaps on dry heat loss through the garment.

    PubMed

    Mert, Emel; Psikuta, Agnes; Bueno, Marie-Ange; Rossi, René M

    2015-11-01

    In real life conditions, the trapped air between the human body and the garment has uneven shape and vary over the body parts as a consequence of the complex geometry of the human body. However, the existing clothing models assume uniform air layer between the human body and the garment or its full contact, which may cause large error in the output of simulations. Therefore, the aim of this study was to investigate the effect of a heterogeneous vertical air gap with different configuration of folds (size and frequency) on dry heat loss using a heated cylinder (Torso). It was found that the presence of folds in the garment led to an increased heat loss from the body in comparison to a homogeneous air gap of comparable size. Interestingly, the size of folds did not have an influence on the dry heat loss. Additionally, the effect of the contact area on dry heat loss became important when exceeding a threshold of about 42%. The results from this study are useful for modelling of a realistic dry heat loss through the clothing and contribute to the improvement of design of protective and active sport garments. PMID:25796204

  13. Comparison of pollutant concentrations from weekly discrete versus composite samples for residential dry-weather runoff.

    PubMed

    Pitton, B J L; Dodge, L L; Gan, J; Greco, S E; Haver, D L; Lee, E; Majcherek, T J; Oki, L R

    2016-09-15

    As urbanization has increased, so has degradation of urban streams. Urban water quality monitoring has focused on storm runoff sampling, but in arid climates, dry-weather runoff is a significant contributor of pollutants to aquatic systems. The majority of dry-weather runoff studies sample a small window of the entire dry-season. For this study constituent concentrations were compared using two sampling protocols. The first protocol repeatedly collected samples on the same day of the week at the same time of day. The second protocol collected samples during two week-long intensive sampling events consisting of sample collection every hour for 24 h for seven consecutive days. The two protocols were compared to determine if sampling at the same time of the week was representative of the entire week. For nitrate, total phosphorous, fipronil, permethrin, total organic carbon, and total suspended solids, sampling at the same time was not representative of the weekly mean; however, variability was observed between sites and constituents. For those constituent concentrations with significant differences seen between the two protocols, load adjustment factors (LAF) were determined, using a ratio of treatment means, and employed to adjust dry-season load estimates. Future work should include determining if LAF values can be used at similar sites excluded from the study or for similar constituents from the current sampling sites. PMID:27192386

  14. Presence of organophosphorus pesticide oxygen analogs in air samples

    PubMed Central

    Armstrong, Jenna L.; Fenske, Richard A.; Yost, Michael G.; Galvin, Kit; Tchong-French, Maria; Yu, Jianbo

    2012-01-01

    A number of recent toxicity studies have highlighted the increased potency of oxygen analogs (oxons) of several organophosphorus (OP) pesticides. These findings were a major concern after environmental oxons were identified in environmental samples from air and surfaces following agricultural spray applications in California and Washington State. This paper reports on the validity of oxygen analog measurements in air samples for the OP pesticide, chlorpyrifos. Controlled environmental and laboratory experiments were used to examine artificial formation of chlorpyrifos-oxon using OSHA Versatile Sampling (OVS) tubes as recommended by NIOSH method 5600. Additionally, we compared expected chlorpyrifos-oxon attributable to artificial transformation to observed chlorpyrifos-oxon in field samples from a 2008 Washington State Department of Health air monitoring study using non-parametric statistical methods. The amount of artificially transformed oxon was then modeled to determine the amount of oxon present in the environment. Toxicity equivalency factors (TEFs) for chlorpyrifos-oxon were used to calculate chlorpyrifos-equivalent air concentrations. The results demonstrate that the NIOSH-recommended sampling matrix (OVS tubes with XAD-2 resin) was found to artificially transform up to 30% of chlorpyrifos to chlorpyrifos-oxon, with higher percentages at lower concentrations (< 30 ng/m3) typical of ambient or residential levels. Overall, the 2008 study data had significantly greater oxon than expected by artificial transformation, but the exact amount of environmental oxon in air remains difficult to quantify with the current sampling method. Failure to conduct laboratory analysis for chlorpyrifos-oxon may result in underestimation of total pesticide concentration when using XAD-2 resin matrices for occupational or residential sampling. Alternative methods that can accurately measure both OP pesticides and their oxygen analogs should be used for air sampling, and a toxicity

  15. Presence of organophosphorus pesticide oxygen analogs in air samples

    NASA Astrophysics Data System (ADS)

    Armstrong, Jenna L.; Fenske, Richard A.; Yost, Michael G.; Galvin, Kit; Tchong-French, Maria; Yu, Jianbo

    2013-02-01

    A number of recent toxicity studies have highlighted the increased potency of oxygen analogs (oxons) of several organophosphorus (OP) pesticides. These findings were a major concern after environmental oxons were identified in environmental samples from air and surfaces following agricultural spray applications in California and Washington State. This paper reports on the validity of oxygen analog measurements in air samples for the OP pesticide, chlorpyrifos. Controlled environmental and laboratory experiments were used to examine artificial formation of chlorpyrifos-oxon using OSHA Versatile Sampling (OVS) tubes as recommended by NIOSH method 5600. Additionally, we compared expected chlorpyrifos-oxon attributable to artificial transformation to observed chlorpyrifos-oxon in field samples from a 2008 Washington State Department of Health air monitoring study using non-parametric statistical methods. The amount of artificially transformed oxon was then modeled to determine the amount of oxon present in the environment. Toxicity equivalency factors (TEFs) for chlorpyrifos-oxon were used to calculate chlorpyrifos-equivalent air concentrations. The results demonstrate that the NIOSH-recommended sampling matrix (OVS tubes with XAD-2 resin) was found to artificially transform up to 30% of chlorpyrifos to chlorpyrifos-oxon, with higher percentages at lower concentrations (<30 ng m-3) typical of ambient or residential levels. Overall, the 2008 study data had significantly greater oxon than expected by artificial transformation, but the exact amount of environmental oxon in air remains difficult to quantify with the current sampling method. Failure to conduct laboratory analysis for chlorpyrifos-oxon may result in underestimation of total pesticide concentration when using XAD-2 resin matrices for occupational or residential sampling. Alternative methods that can accurately measure both OP pesticides and their oxygen analogs should be used for air sampling, and a toxicity

  16. A simple novel device for air sampling by electrokinetic capture

    DOE PAGESBeta

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A.

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of

  17. A simple novel device for air sampling by electrokinetic capture

    SciTech Connect

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A.

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the

  18. Innovations in air sampling to detect plant pathogens

    PubMed Central

    West, JS; Kimber, RBE

    2015-01-01

    Many innovations in the development and use of air sampling devices have occurred in plant pathology since the first description of the Hirst spore trap. These include improvements in capture efficiency at relatively high air-volume collection rates, methods to enhance the ease of sample processing with downstream diagnostic methods and even full automation of sampling, diagnosis and wireless reporting of results. Other innovations have been to mount air samplers on mobile platforms such as UAVs and ground vehicles to allow sampling at different altitudes and locations in a short space of time to identify potential sources and population structure. Geographical Information Systems and the application to a network of samplers can allow a greater prediction of airborne inoculum and dispersal dynamics. This field of technology is now developing quickly as novel diagnostic methods allow increasingly rapid and accurate quantifications of airborne species and genetic traits. Sampling and interpretation of results, particularly action-thresholds, is improved by understanding components of air dispersal and dilution processes and can add greater precision in the application of crop protection products as part of integrated pest and disease management decisions. The applications of air samplers are likely to increase, with much greater adoption by growers or industry support workers to aid in crop protection decisions. The same devices are likely to improve information available for detection of allergens causing hay fever and asthma or provide valuable metadata for regional plant disease dynamics. PMID:25745191

  19. Effect of additives and steaming on quality of air dried noodles.

    PubMed

    Gatade, Abhijeet Arun; Sahoo, Akshaya Kumar

    2015-12-01

    Texture is the most important property for consumer acceptance in cooked noodles. The air dried noodles are known to have higher cooking loss and cooking time, to that of instant fried noodles. But the fat content of instant fried noodles is more. In the present work attempts were made to optimize the moisture content so as to obtain a smooth dough for extruded noodle preparation and develop air dried noodles of low fat content with lesser cooking loss and cooking time. To meet the objectives, the effect of various additives and steaming treatment on cooking quality, sensory attributes, textural properties and microstructure of noodles were studied. Dough prepared by addition of 40 ml water to 100 g flour resulted into formation of a soft dough, leading to production of noodles of improved surface smoothness and maximum yield. The use of additives (5 g oil, 0.2 g guar gum, 2 g gluten and 1 ml of 1 % kansui solution for 100 g of flour) and steaming treatment showed significant effect on noodles quality, with respect to cooking characteristics, sensory attributes and textural properties. The microstructure images justified the positive correlation between the effects of ingredients with steaming and quality parameters of noodles. Air dried noodles with reduced cooking loss (~50 % reduction) with marginal reduction in cooking time was developed, which were having similar characteristics to that of instant fried noodles. Compared to the instant fried noodle, the prepared air dried noodle was having substantially reduced fat content (~70 % reduction). Thus the present study will be useful for guiding extrusion processes for production of air dried noodles having less cooking time and low fat content. PMID:26604421

  20. Air permeability of powder: a potential tool for Dry Powder Inhaler formulation development.

    PubMed

    Le, V N P; Robins, E; Flament, M P

    2010-11-01

    Dry Powder Inhalers have drawn great attention from pharmaceutical scientists in recent years in particular those consisting of low-dose micronized drug particles associated with larger carrier particles and called interactive mixtures. However, there is little understanding of the relation between bulk powder properties such as powder structure and its aerodynamic dispersion performance. The aim of this work was to develop a simple method to measure the air permeability of interactive mixtures used in Dry Powder Inhalers by using Blaine's apparatus--a compendial permeameter and to relate it to the aerodynamic behaviour. The study was done with fluticasone propionate and terbutaline sulphate as drug models that were blended with several lactoses having different particle size distribution thus containing different percentages of fine particle lactose. The quality of the blends was examined by analysing the drug content uniformity. Aerodynamic evaluation of fine particle fraction was obtained using a Twin Stage Impinger. A linear correlation between a bulk property--air permeability of packed powder bed--and the fine particle fraction of drug was observed for the tested drugs. The air permeability reflects the quantity of the free particle fraction in the interparticulate spaces of powder bed that leads to fine particle fraction during fluidization in air flow. A theoretical approach was developed in order to link the air permeability of powder bed and drag force acting on powders during aerosolization process. The permeability technique developed in this study provides a potential tool for screening Dry Powder Inhaler formulations at the development stage. PMID:20854906

  1. Operational air sampling report, July--December 1991

    SciTech Connect

    Lyons, C.L.

    1992-11-01

    Air sampling is one of the more useful ways of assessing the effectiveness of operational radiation safety programs at the Nevada Test Site (NTS). Air sampling programs document NTS airborne radionuclide concentrations in various work locations and environments. These concentrations generally remain well below the Derived Air Concentration (DAC) values prescribed by the Department of Energy (DOE 5480.11, Attachment 1) or the Derived Concentration Guide (DCG) values prescribed by the Department of Energy DOE 5400.5, Chapter Ill. The Defense Nuclear Agency (DNA) tunnel complexes, Area 12 Test Support Compound and the Area 6 Decontamination Pad and Laundry air sampling programs are summarized in this report. Evaluations are based on Analytical Services Department (ASD) Counting Laboratory analyses and Health Protection Department (HPD)/Radiological Field Operations Section (RFOS) radiation protection technician's (RPT) or health physicists' calculations for air samples collected July 1 through December 31, 1991. Of the NTS operational air sampling programs in the tunnel complexes, the initial mining and event reentry and recovery operations represent the only real airborne radioactive inhalation potentials to personnel. Monthly filter and scintillation cell samples were taken and counted in RDA-200 Radon Detectors to document working levels of radon/thoron daughters and picocurie/liter (PCVL) concentrations of radon gas. Weekly Drierite samples for tritium analysis were taken in the active tunnel complexes to document any changes in normal background levels or reentry drifts as they are advanced toward ground zero (GZ) areas. Underground water sources are considered primary transporters of tritium from old event areas.

  2. Operational air sampling report, July--December 1991

    SciTech Connect

    Lyons, C.L.

    1992-11-01

    Air sampling is one of the more useful ways of assessing the effectiveness of operational radiation safety programs at the Nevada Test Site (NTS). Air sampling programs document NTS airborne radionuclide concentrations in various work locations and environments. These concentrations generally remain well below the Derived Air Concentration (DAC) values prescribed by the Department of Energy (DOE 5480.11, Attachment 1) or the Derived Concentration Guide (DCG) values prescribed by the Department of Energy DOE 5400.5, Chapter Ill. The Defense Nuclear Agency (DNA) tunnel complexes, Area 12 Test Support Compound and the Area 6 Decontamination Pad and Laundry air sampling programs are summarized in this report. Evaluations are based on Analytical Services Department (ASD) Counting Laboratory analyses and Health Protection Department (HPD)/Radiological Field Operations Section (RFOS) radiation protection technician`s (RPT) or health physicists` calculations for air samples collected July 1 through December 31, 1991. Of the NTS operational air sampling programs in the tunnel complexes, the initial mining and event reentry and recovery operations represent the only real airborne radioactive inhalation potentials to personnel. Monthly filter and scintillation cell samples were taken and counted in RDA-200 Radon Detectors to document working levels of radon/thoron daughters and picocurie/liter (PCVL) concentrations of radon gas. Weekly Drierite samples for tritium analysis were taken in the active tunnel complexes to document any changes in normal background levels or reentry drifts as they are advanced toward ground zero (GZ) areas. Underground water sources are considered primary transporters of tritium from old event areas.

  3. Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling.

    PubMed Central

    Buttner, M P; Stetzenbach, L D

    1993-01-01

    Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments. PMID:8439150

  4. Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards

    SciTech Connect

    Glissmeyer, John A.; Flaherty, Julia E.; Pekour, Mikhail S.

    2014-12-02

    The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system must also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer

  5. EVALUATION OF HIGH VOLUME PARTICLE SAMPLING AND SAMPLE HANDLING PROTOCOLS FOR AMBIENT URBAN AIR MUTAGENICITY DETERMINATIONS

    EPA Science Inventory

    An investigation of high volume particle sampling and sample handling procedures was undertaken to evaluate variations of protocols being used by the U.S Environmental Protection Agency. hese protocols are used in urban ambient air studies which collect ambient and source samples...

  6. Continuous monitoring of polychlorinated biphenyls in air using direct sampling APCI/ITMS

    NASA Astrophysics Data System (ADS)

    Yamada, Masuyoshi; Suga, Masao; Waki, Izumi; Sakamoto, Masami; Morita, Masatoshi

    2005-06-01

    We report a continuous monitoring system of polychlorinated biphenyls (PCBs) in air, which uses direct sampling atmospheric pressure chemical ionization (APCI)/ion trap mass spectrometry (ITMS). In APCI, humidity in the atmosphere, which fluctuates from 0 to 10 vol.%, influences PCB sensitivity. In dry air (0.5% humidity), the detection limits of Di- to Hp-chlorinated biphenyls (CB) are 0.01-0.44 [mu]g/Nm3 ([mu]g/m3 at normal condition) with time resolution of 1 min, whereas the sensitivity decreases to less than 1/10 when water vapor concentration is 10 vol.%. The sensitivity decrease is calibrated in real-time using an internal standard, trichlorophenol. In order to obtain the calibration accuracy of +/-30%, we dilute the sample gas by dry air, decreasing the water vapor concentration below 1%. We applied the monitor to measure Di- to Hp-CB in ventilation air from a PCB decomposition plant. The monitored PCB concentration levels agreed well with that by high-resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS).

  7. Air Monitoring: New Advances in Sampling and Detection

    PubMed Central

    Watson, Nicola; Davies, Stephen; Wevill, David

    2011-01-01

    As the harmful effects of low-level exposure to hazardous organic air pollutants become more evident, there is constant pressure to improve the detection limits of indoor and ambient air monitoring methods, for example, by collecting larger air volumes and by optimising the sensitivity of the analytical detector. However, at the other end of the scale, rapid industrialisation in the developing world and growing pressure to reclaim derelict industrial land for house building is driving the need for air monitoring methods that can reliably accommodate very-high-concentration samples in potentially aggressive matrices. This paper investigates the potential of a combination of two powerful gas chromatography—based analytical enhancements—sample preconcentration/thermal desorption and time-of-flight mass spectrometry—to improve quantitative and qualitative measurement of very-low-(ppt) level organic chemicals, even in the most complex air samples. It also describes new, practical monitoring options for addressing equally challenging high-concentration industrial samples. PMID:22241966

  8. Drying and storage methods affect cyfluthrin concentrations in exposed plant samples

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Standard procedures exist for collection and chemical analyses of pyrethroid insecticides in environmental matrices. However, less detail is given for drying and potential storage methods of plant samples prior to analyses. Due to equipment and financial limitations, immediate sample analysis is n...

  9. Effect of air velocity on kinetics of thin layer carrot pomace drying.

    PubMed

    Kumar, N; Sarkar, B C; Sharma, H K

    2011-10-01

    Carrot pomace is a by-product obtained during carrot juice processing. Thin layer carrot pomace drying was performed in a laboratory scale hot air forced convective dryer. The drying experiments were carried out at the air velocity of 0.5, 0.7 and 1.0 m/s at air temperatures from 60 to 75 °C. It was observed that whole drying process of carrot pomace took place in a falling rate period except a very short accelerating period at the beginning. Mathematical models were tested to fit drying data of carrot pomace. The best fit model was observed on the basis of R², Chi-square and RMSE values. R² values for all the selected models were above 0.9783. The average values of effective diffusivity ranged from 2.61 × 10(-9) to 3.64 × 10(-9) m²/s. PMID:21954311

  10. Final report on CCQM-P151: Halocarbons in dry whole air

    NASA Astrophysics Data System (ADS)

    Rhoderick, George; Guenther, Franklin; Duewer, David; Lee, Jeongsoon; Seog Kim, Jin; Hall, Bradley; Weiss, Ray; Harth, Christina; Reimann, Stefan; Vollmer, Martin

    2014-01-01

    The growing awareness of climate change/global warming and continuing concerns regarding stratospheric ozone depletion will require future measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track and control the emissions of these species globally in the atmosphere, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. This report describes the results of a pilot study between National Metrology Institutes and atmospheric research laboratories for several of the more important halocarbons at atmospheric concentration levels. The comparison includes the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC 12), trichlorofluoromethane (CFC 11), and 1,1,2-trichlorotrifluoroethane (CFC 113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC 22) and 1-chloro-1,1-difluoroethane (HCFC 142b); and the hydrofluorocarbon (HFC) 1,1,1,2-tetrafluoroethane (HFC 134a), all in a dried whole air sample. The objective of this key comparison is to compare the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM.

  11. Final report on international comparison CCQM-K83: Halocarbons in dry whole air

    NASA Astrophysics Data System (ADS)

    Rhoderick, George; Guenther, Franklin; Duewer, David; Lee, Jeongsoon; Moon, Dongmin; Lee, Jinbok; Lim, Jeongsik; Seog Kim, Jin

    2014-01-01

    The growing awareness of climate change/global warming and continuing concerns regarding stratospheric ozone depletion will require future measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track and control the emissions of these species globally in the atmosphere, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. This report describes the results of a key comparison for several of the more important halocarbons at atmospheric concentration levels. The comparison includes the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC 12), trichlorofluoromethane (CFC 11), and 1,1,2 trichlorotrifluoroethane (CFC 113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC 22) and 1-chloro-1,1-difluoroethane (HCFC 142b); and the hydrofluorocarbon (HFC) 1,1,1,2 tetrafluoroethane (HFC 134a), all in a dried whole air sample. The objective of this key comparison is to compare the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. DUS II SOIL GAS SAMPLING AND AIR INJECTION TEST RESULTS

    SciTech Connect

    Noonkester, J.; Jackson, D.; Jones, W.; Hyde, W.; Kohn, J.; Walker, R.

    2012-09-20

    Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected

  13. A study of the differences between two amorphous spray-dried samples of cefditoren pivoxil which exhibited different physical stabilities.

    PubMed

    Ohta, Masato; Buckton, Graham

    2005-01-31

    The objective of this study was to investigate the reasons for the difference in physical stability of two amorphous cefditoren pivoxil samples that had been prepared using spray drying at inlet-air temperatures of 40 degrees C (SD-A) and 100 degrees C (SD-B). The two samples appeared amorphous by powder X-ray diffraction and had indistinguishable glass transition temperatures. Despite the fact that glass transition is often regarded as an indicator of the stability of amorphous forms, crystallisation was observed for SD-A, but not for SD-B, during storage at 60 degrees C and 81% relative humidity (RH). Gravimetric water sorption data demonstrated very similar water sorption until high RH values, at which point SD-A sorbed more water than did SD-B. The values of the dispersive, acidic (K(A)) and basic (K(D)) components of surface energy of the spray-dried samples were obtained using inverse gas chromatography (IGC), in the dry state and after equilibration with different RH environments. The data showed that the two amorphous samples had different surface properties and that the effect of sorbed water on these samples was also different. It is concluded that the two samples did not have long-range order, but had differences in the orientation of molecules at the surface, which were significant enough to alter the stability when the samples were stressed with water vapour and high temperature storage. IGC proved a valuable tool with which to study changes in the surface properties of amorphous materials. PMID:15652196

  14. Potential of Dried Blood Self-Sampling for Cyclosporine C2 Monitoring in Transplant Outpatients

    PubMed Central

    Leichtle, Alexander Benedikt; Ceglarek, Uta; Witzigmann, Helmut; Gäbel, Gábor; Thiery, Joachim; Fiedler, Georg Martin

    2010-01-01

    Background. Close therapeutic drug monitoring of Cyclosporine (CsA) in transplant outpatients is a favourable procedure to maintain the long-term blood drug levels within their respective narrow therapeutic ranges. Compared to basal levels (C0), CsA peak levels (C2) are more predictive for transplant rejection. However, the application of C2 levels is hampered by the precise time of blood sampling and the need of qualified personnel. Therefore, we evaluated a new C2 self-obtained blood sampling in transplant outpatients using dried capillary and venous blood samples and compared the CsA levels, stability, and clinical practicability of the different procedures. Methods. 55 solid organ transplant recipients were instructed to use single-handed sampling of each 50 μL capillary blood and dried blood spots by finger prick using standard finger prick devices. We used standardized EDTA-coated capillary blood collection systems and standardized filter paper WS 903. CsA was determined by LC-MS/MS. The patients and technicians also answered a questionnaire on the procedure and sample quality. Results. The C0 and C2 levels from capillary blood collection systems (C0 [ng/mL]: 114.5 ± 44.5; C2: 578.2 ± 222.2) and capillary dried blood (C0 [ng/mL]: 175.4 ± 137.7; C2: 743.1 ± 368.1) significantly (P < .01) correlated with the drug levels of the venous blood samples (C0 [ng/mL]: 97.8 ± 37.4; C2: 511.2 ± 201.5). The correlation at C0 was ρcap.-ven. = 0.749, and ρdried blood-ven = 0.432; at C2: ρcap.-ven. = 0.861 and ρdried blood-ven = 0.711. The patients preferred the dried blood sampling because of the more simple and less painful procedure. Additionally, the sample quality of self-obtained dried blood spots for LC-MS/MS analytics was superior to the respective capillary blood samples. Conclusions. C2 self-obtained dried blood sampling can easily be performed by transplant outpatients and is therefore suitable and cost-effective for close therapeutic drug monitoring

  15. Optimum dry-cooling sub-systems for a solar air conditioner

    NASA Technical Reports Server (NTRS)

    Chen, J. L. S.; Namkoong, D.

    1978-01-01

    Dry-cooling sub-systems for residential solar powered Rankine compression air conditioners were economically optimized and compared with the cost of a wet cooling tower. Results in terms of yearly incremental busbar cost due to the use of dry-cooling were presented for Philadelphia and Miami. With input data corresponding to local weather, energy rate and capital costs, condenser surface designs and performance, the computerized optimization program yields design specifications of the sub-system which has the lowest annual incremental cost.

  16. Microorganisms cultured from stratospheric air samples obtained at 41 km.

    PubMed

    Wainwright, M; Wickramasinghe, N C; Narlikar, J V; Rajaratnam, P

    2003-01-21

    Samples of air removed from the stratosphere, at an altitude of 41 km, were previously found to contain viable, but non-cultureable bacteria (cocci and rods). Here, we describe experiments aimed at growing these, together with any other organisms, present in these samples. Two bacteria (Bacillus simplex and Staphylococcus pasteuri) and a single fungus, Engyodontium album (Limber) de Hoog were isolated from the samples. Although the possibility of contamination can never be ruled out when space-derived samples are studied on earth, we are confident that the organisms originated from the stratosphere. Possible mechanisms by which these organisms could have attained such a height are discussed. PMID:12583913

  17. Sampling frequency guidance for ambient air toxics monitoring.

    PubMed

    Bortnick, Steven M; Stetzer, Shannon L

    2002-07-01

    The U.S. Environmental Protection Agency (EPA) is in the process of designing a national network to monitor hazardous air pollutants (HAPs), also known as air toxics. The purposes of the expanded monitoring are to (1) characterize ambient concentrations in representative areas; (2) provide data to support and evaluate dispersion and receptor models; and (3) establish trends and evaluate the effectiveness of HAP emission reduction strategies. Existing air toxics data, in the form of an archive compiled by EPA's Office of Air Quality Planning and Standards (OAQPS), are used in this paper to examine the relationship between estimated annual average (AA) HAP concentrations and their associated variability. The goal is to assess the accuracy, or bias and precision, with which the AA can be estimated as a function of ambient concentration levels and sampling frequency. The results suggest that, for several air toxics, a sampling schedule of 1 in 3 days (1:3) or 1:6 days maybe appropriate for meeting some of the general objectives of the national network, with the more intense sampling rate being recommended for areas expected to exhibit relatively high ambient levels. PMID:12139351

  18. Bioassay vs. Air Sampling: Practical Guidance and Experience at Hanford

    SciTech Connect

    Carbaugh, Eugene H.; Carlson, Eric W.; Hill, Robin L.

    2004-02-08

    The Hanford Site has implemented a policy to guide in determining whether air sampling data or special fecal bioassay data are more appropriate for determining doses of record for low-level plutonium exposures. The basis for the policy and four years of experience in comparing DAC-hours exposure with bioassay-based dosimetry is discussed.

  19. TETHERED BALLOON SAMPLING SYSTEMS FOR MONITORING AIR POLLUTION

    EPA Science Inventory

    The paper is an overview of recent studies in which balloons, usually tethered, have been used to investigate the structure and air quality of the planetary boundary layer. It also describes a number of lightweight tethered balloon sampling systems, developed to investigate parti...

  20. Drying and Storage Methods Affect Cyfluthrin Concentrations in Exposed Plant Samples.

    PubMed

    Moore, M T; Kröger, R; Locke, M A

    2016-08-01

    Standard procedures do not exist for drying and storage of plant samples prior to chemical analyses. Since immediate analysis is not always possible, current research examined which plant drying and storage method yielded the highest cyfluthrin recovery rates compared to traditional mechanical freeze-drying methods. Fifteen mesocosms were planted with rice. Cyfluthrin (5 mg L(-1)) was amended into the water column of individual mesocosms. 48 h later, plant material in the water column was collected from each mesocosm. Control (mechanical freeze drying) recovery was significantly greater (p < 0.001) than all 14 combinations of drying and storage. Significant differences also existed between all 14 different combinations. Greatest cyfluthrin recoveries in non-control plants were from the freezer-greenhouse-freezer drying and storage method. Results offer evidence for the efficient plant drying and storage methods prior to cyfluthrin analysis. Future studies should perform comparable analyses on various pesticide classes to determine possible relationships. PMID:27225509

  1. Comparison of VOC emissions between air-dried and heat-treated Norway spruce ( Picea abies), Scots pine ( Pinus sylvesteris) and European aspen ( Populus tremula) wood

    NASA Astrophysics Data System (ADS)

    Hyttinen, Marko; Masalin-Weijo, Marika; Kalliokoski, Pentti; Pasanen, Pertti

    2010-12-01

    Heat-treated wood is an increasingly popular decoration material. Heat-treatment improves dimensional stability of the wood and also prevents rot fungus growth. Although production of heat-treated wood has been rapidly increasing, there is only little information about the VOC emissions of heat-treated wood and its possible influences on indoor air quality. In the present study, VOC emissions from three untreated (air-dried) and heat-treated wood species were compared during a four weeks test period. It appeared that different wood species had clearly different VOC emission profiles. Heat-treatment was found to decrease VOC emissions significantly and change their composition. Especially, emissions of terpenes decreased from softwood samples and aldehydes from European aspen samples. Emissions of total aldehydes and organic acids were at the same level or slightly higher from heat treated than air-dried softwood samples. In agreement with another recent study, the emissions of furfural were found to increase and those of hexanal to decrease from all the wood species investigated. In contrast to air-dried wood samples, emissions of VOCs were almost in steady state from heat treated wood samples even in the beginning of the test.

  2. Electro-Hydrodynamics and Kinetic Modeling of Dry and Humid Air Flows Activated by Corona Discharges

    NASA Astrophysics Data System (ADS)

    P. Sarrette, J.; Eichwald, O.; Marchal, F.; Ducasse, O.; Yousfi, M.

    2016-05-01

    The present work is devoted to the 2D simulation of a point-to-plane Atmospheric Corona Discharge Reactor (ACDR) powered by a DC high voltage supply. The corona reactor is periodically crossed by thin mono filamentary streamers with a natural repetition frequency of some tens of kHz. The study compares the results obtained in dry air and in air mixed with a small amount of water vapour (humid air). The simulation involves the electro-dynamics, chemical kinetics and neutral gas hydrodynamics phenomena that influence the kinetics of the chemical species transformation. Each discharge lasts about one hundred of a nanosecond while the post-discharge occurring between two successive discharges lasts one hundred of a microsecond. The ACDR is crossed by a lateral dry or humid air flow initially polluted with 400 ppm of NO. After 5 ms, the time corresponding to the occurrence of 50 successive discharge/post-discharge phases, a higher NO removal rate and a lower ozone production rate are found in humid air. This change is due to the presence of the HO2 species formed from the H primary radical in the discharge zone.

  3. Urinary CC16 after challenge with dry air hyperpnoea and mannitol in recreational summer athletes.

    PubMed

    Kippelen, Pascale; Tufvesson, Ellen; Ali, Leena; Bjermer, Leif; Anderson, Sandra D

    2013-12-01

    Airway epithelial injury is regarded as a key contributing factor to the pathogenesis of exercise-induced bronchoconstriction (EIB) in athletes. The concentration of the pneumoprotein club cell (Clara cell) CC16 in urine has been found to be a non-invasive marker for hyperpnoea-induced airway epithelial perturbation. Exercise-hyperpnoea induces mechanical, thermal and osmotic stress to the airways. We investigated whether osmotic stress alone causes airway epithelial perturbation in athletes with suspected EIB. Twenty-four recreational summer sports athletes who reported respiratory symptoms on exertion performed a standard eucapnic voluntary hyperpnoea test with dry air and a mannitol test (osmotic challenge) on separate days. Median urinary CC16 increased from 120 to 310 ρg μmol creatinine(-1) after dry air hyperpnoea (P = 0.002) and from 90 to 191 ρg μmol creatinine(-1) after mannitol (P = 0.021). There was no difference in urinary CC16 concentration between athletes who did or did not bronchoconstrict after dry air hyperpnoea or mannitol. We conclude that, in recreational summer sports athletes with respiratory symptoms, osmotic stress per se to the airway epithelium induces a rise in urinary excretion of CC16. This suggests that hyperosmolarity of the airway surface lining perturbs the airway epithelium in symptomatic athletes. PMID:24120076

  4. Effect of green roofs on air temperature; measurement study of well-watered and dry conditions

    NASA Astrophysics Data System (ADS)

    Solcerova, Anna; van de Ven, Frans; Wang, Mengyu; van de Giesen, Nick

    2016-04-01

    Rapid urbanization and increasing number and duration of heat waves poses a need for understanding urban climate and ways to mitigate extremely high temperatures. One of repeatedly suggested and often investigated methods to moderate the so called urban heat island are green roofs. This study investigates several extensive green roofs in Utrecht (NL) and their effect on air temperature right above the roof surface. Air temperature was measured 15 and 30 cm above the roof surface and also in the substrate. We show that under normal condition is air above green roof, compared to white gravel roof, colder at night and warmer during day. This suggest that green roofs might help decrease air temperatures at night, when the urban heat island is strongest, but possibly contribute to high temperatures during daytime. We also measured situation when the green roofs wilted and dried out. Under such conditions green roof exhibits more similar behavior to conventional white gravel roof. Interestingly, pattern of soil temperature remains almost the same for both dry and well-prospering green roof, colder during day and warmer at night. As such, green roof works as a buffer of diurnal temperature changes.

  5. Elemental distribution and sample integrity comparison of freeze-dried and frozen-hydrated biological tissue samples with nuclear microprobe

    NASA Astrophysics Data System (ADS)

    Vavpetič, P.; Vogel-Mikuš, K.; Jeromel, L.; Ogrinc Potočnik, N.; Pongrac, P.; Drobne, D.; Pipan Tkalec, Ž.; Novak, S.; Kos, M.; Koren, Š.; Regvar, M.; Pelicon, P.

    2015-04-01

    The analysis of biological samples in frozen-hydrated state with micro-PIXE technique at Jožef Stefan Institute (JSI) nuclear microprobe has matured to a point that enables us to measure and examine frozen tissue samples routinely as a standard research method. Cryotome-cut slice of frozen-hydrated biological sample is mounted between two thin foils and positioned on the sample holder. The temperature of the cold stage in the measuring chamber is kept below 130 K throughout the insertion of the samples and the proton beam exposure. Matrix composition of frozen-hydrated tissue is consisted mostly of ice. Sample deterioration during proton beam exposure is monitored during the experiment, as both Elastic Backscattering Spectrometry (EBS) and Scanning Transmission Ion Microscopy (STIM) in on-off axis geometry are recorded together with the events in two PIXE detectors and backscattered ions from the chopper in a single list-mode file. The aim of this experiment was to determine differences and similarities between two kinds of biological sample preparation techniques for micro-PIXE analysis, namely freeze-drying and frozen-hydrated sample preparation in order to evaluate the improvements in the elemental localisation of the latter technique if any. In the presented work, a standard micro-PIXE configuration for tissue mapping at JSI was used with five detection systems operating in parallel, with proton beam cross section of 1.0 × 1.0 μm2 and a beam current of 100 pA. The comparison of the resulting elemental distributions measured at the biological tissue prepared in the frozen-hydrated and in the freeze-dried state revealed differences in elemental distribution of particular elements at the cellular level due to the morphology alteration in particular tissue compartments induced either by water removal in the lyophilisation process or by unsatisfactory preparation of samples for cutting and mounting during the shock-freezing phase of sample preparation.

  6. Can car air filters be useful as a sampling medium for air pollution monitoring purposes?

    PubMed

    Katsoyiannis, Athanasios; Birgul, Askin; Ratola, Nuno; Cincinelli, Alessandra; Sweetman, Andy J; Jones, Kevin C

    2012-11-01

    Urban air quality and real human exposure to chemical environmental stressors is an issue of high scientific and political interest. In an effort to find innovative and inexpensive means for air quality monitoring, the ability of car engine air filters (CAFs) to act as efficient samplers collecting street level air, to which people are exposed to, was tested. In particular, in the case of taxis, air filters are replaced after regular distances, the itineraries are almost exclusively urban, cruising mode is similar and, thus, knowledge of the air flow can provide with an integrated city air sample. The present pilot study focused on polycyclic aromatic hydrocarbons (PAHs), the most important category of organic pollutants associated with traffic emissions. Concentrations of ΣPAHs in CAFs ranged between 650 and 2900 μg CAF(-1), with benzo[b]fluoranthene, benzo[k]fluoranthene and indeno[123-cd]pyrene being the most abundant PAHs. Benzo[a]pyrene (BaP) ranged between 110 and 250 μg CAF(-1), accounting regularly for 5-15% of the total carcinogenic PAHs. The CAF PAH loads were used to derive road-level atmospheric PAH concentrations from a standard formula relating to the CAF air flow. Important parameters/assumptions for these estimates are the cruising speed and the exposure duration of each CAF. Based on information obtained from the garage experts, an average 'sampled air volume' of 48,750 m(3) per CAF was estimated, with uncertainty in this calculation estimated to be about a factor of 4 between the two extreme scenarios. Based on this air volume, ΣPAHs ranged between 13 and 56 ng m(-3) and BaP between 2.1 and 5.0 ng m(-3), suggesting that in-traffic BaP concentrations can be many times higher than the limit values set by the UK (0.25 ng m(-3)) and the European Union (1.0 ng m(-3)), or from active sampling stations normally cited on building roof tops or far from city centres. Notwithstanding the limitations of this approach, the very low cost, the continuous

  7. RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY AIR FILTER SAMPLES

    SciTech Connect

    Maxwell, S.; Noyes, G.; Culligan, B.

    2010-02-03

    A new rapid method for the determination of actinides and strontium in air filter samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations. The actinides and strontium in air filter method utilizes a rapid acid digestion method and a streamlined column separation process with stacked TEVA, TRU and Sr Resin cartridges. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha emitters are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The purified {sup 90}Sr fractions are mounted directly on planchets and counted by gas flow proportional counting. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency air filter samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinide and {sup 90}Sr in air filter results were reported in {approx}4 hours with excellent quality.

  8. Influence of material structure on air-borne ultrasonic application in drying.

    PubMed

    Ozuna, César; Gómez Álvarez-Arenas, Tomás; Riera, Enrique; Cárcel, Juan A; Garcia-Perez, Jose V

    2014-05-01

    This work aims to contribute to the understanding of how the properties of the material being dried affect air-borne ultrasonic application. To this end, the experimental drying kinetics (40°C and 1m/s) of cassava (Manihot esculenta) and apple (Malus domestica var. Granny Smith) were carried out applying different ultrasonic powers (0, 6, 12, 19, 25 and 31 kW/m(3)). Furthermore, the power ultrasound-assisted drying kinetics of different fruits and vegetables (potato, eggplant, carrot, orange and lemon peel) already reported in previous studies were also analyzed. The structural, textural and acoustic properties of all these products were assessed, and the drying kinetics modeled by means of the diffusion theory. A significant linear correlation (r>0.95) was established between the identified effective diffusivity (DW) and the applied ultrasonic power for the different products. The slope of this relationship (SDUP) was used as an index of the effectiveness of the ultrasonic application; thus the higher the SDUP, the more effective the ultrasound application. SDUP was well correlated (r ⩾ 0.95) with the porosity and hardness. In addition, SDUP was largely affected by the acoustic impedance of the material being dried, showing a similar pattern with the impedance than the transmission coefficient of the acoustic energy on the interface. Thus, soft and open-porous product structures exhibited a better transmission of acoustic energy and were more prone to the mechanical effects of ultrasound. However, materials with a hard and closed-compact structure were less affected by acoustic energy due to the fact that the significant impedance differences between the product and the air cause high energy losses on the interface. PMID:24411471

  9. Evaluation of membrane filter field monitors for microbiological air sampling

    NASA Technical Reports Server (NTRS)

    Fields, N. D.; Oxborrow, G. S.; Puleo, J. R.; Herring, C. M.

    1974-01-01

    Due to area constraints encountered in assembly and testing areas of spacecraft, the membrane filter field monitor (MF) and the National Aeronautics and Space Administration-accepted Reyniers slit air sampler were compared for recovery of airborne microbial contamination. The intramural air in a microbiological laboratory area and a clean room environment used for the assembly and testing of the Apollo spacecraft was studied. A significantly higher number of microorganisms was recovered by the Reyniers sampler. A high degree of consistency between the two sampling methods was shown by a regression analysis, with a correlation coefficient of 0.93. The MF samplers detected 79% of the concentration measured by the Reyniers slit samplers. The types of microorganisms identified from both sampling methods were similar.

  10. Air temperature evolution during dry spells and its relation to prevailing soil moisture regimes

    NASA Astrophysics Data System (ADS)

    Schwingshackl, Clemens; Hirschi, Martin; Seneviratne, Sonia I.

    2015-04-01

    The complex interplay between land and atmosphere makes accurate climate predictions very challenging, in particular with respect to extreme events. More detailed investigations of the underlying dynamics, such as the identification of the drivers regulating the energy exchange at the land surface and the quantification of fluxes between soil and atmosphere over different land types, are thus necessary. The recently started DROUGHT-HEAT project (funded by the European Research Council) aims to provide better understanding of the processes governing the land-atmosphere exchange. In the first phase of the project, different datasets and methods are used to investigate major drivers of land-atmosphere dynamics leading to droughts and heatwaves. In the second phase, these findings will be used for reducing uncertainties and biases in earth system models. Finally, the third part of the project will focus on the application of the previous findings and use them for the attribution of extreme events to land processes and possible mitigation through land geoengineering. One of the major questions in land-atmosphere exchange is the relationship between air temperature and soil moisture. Different studies show that especially during dry spells soil moisture has a strong impact on air temperature and the amplification of hot extremes. Whereas in dry and wet soil moisture regimes variations in latent heat flux during rain-free periods are expected to be small, this is not the case in transitional soil moisture regimes: Due to decreasing soil moisture content latent heat flux reduces with time, which causes in turn an increase in sensible heat flux and, subsequently, higher air temperatures. The investigation of air temperature evolution during dry spells can thus help to detect different soil moisture regimes and to provide insights on the effect of different soil moisture levels on air temperature. Here we assess the underlying relationships using different observational and

  11. Detection of PAX8/PPARG and RET/PTC Rearrangements Is Feasible in Routine Air-Dried Fine Needle Aspiration Smears

    PubMed Central

    Ferraz, Carolina; Rehfeld, Christian; Krogdahl, Annelise; Precht Jensen, Eva Magrethe; Bösenberg, Eileen; Narz, Frank; Hegedüs, Laszlo; Eszlinger, Markus

    2012-01-01

    Background The diagnostic limitations of fine needle aspiration (FNA), like the indeterminate category, can be partially overcome by molecular analysis. As PAX8/PPARG and RET/PTC rearrangements have been detected in follicular thyroid carcinomas (FTCs) and papillary thyroid carcinomas (PTCs), their detection in FNA smears could improve the FNA diagnosis. To date, these rearrangements have never been analyzed in routine air-dried FNA smears, but only in frozen tissue, formalin-fixed paraffin-embedded (FFPE) tissue, and in fresh FNA material. Fixed routine air-dried FNA samples have hitherto been judged as generally not suitable for testing these rearrangements in a clinical setting. Therefore, the objective of the present study was to investigate the feasibility of extracting RNA from routine air-dried FNA smears for the detection of these rearrangements with real-time polymerase chain reaction (RT-PCR). Methods A new method for RNA extraction from routine air-dried FNA smears was established, which allowed analysis for the presence of four variants of PAX8/PPARG and RET/PTC 1 and RET/PTC 3, which were analyzed in 106 routine FNA smears and the corresponding surgically obtained FFPE tissues using real-time quantitative PCR (RT-qPCR). To assess RNA quality, an intron-spanning PAX8 cDNA was amplified. Results Acceptable RNA quality was obtained from 95% of the FNA samples and 92% of the FFPE samples. PAX8/PPARG was detected in 4 of 96 FFPEs and in 6 of 96 FNAs. PAX8/PPARG was present in 4 of 10 FTCs and in 3 of 42 follicular adenomas (FAs). Similarly, RET/PTC was found in 3 of 96 FFPEs and in 4 of 96 FNAs. Two of 21 PTC samples and 3 of 42 FA samples carried this rearrangement. Conclusion These data are the first to show the feasibility of extracting RNA from routine air-dried FNA smears for the detection of PAX8/PPARG and RET/PTC rearrangements with RT-qPCR. These promising methodological advances, if confirmed in larger series of FNA and FFPE samples, may lead to

  12. Startup of air-cooled condensers and dry cooling towers at low temperatures of the cooling air

    NASA Astrophysics Data System (ADS)

    Milman, O. O.; Ptakhin, A. V.; Kondratev, A. V.; Shifrin, B. A.; Yankov, G. G.

    2016-05-01

    The problems of startup and performance of air-cooled condensers (ACC) and dry cooling towers (DCT) at low cooling air temperatures are considered. Effects of the startup of the ACC at sub-zero temperatures are described. Different options of the ACC heating up are analyzed, and examples of existing technologies are presented (electric heating, heating up with hot air or steam, and internal and external heating). The use of additional heat exchanging sections, steam tracers, in the DCT design is described. The need for high power in cases of electric heating and heating up with hot air is noted. An experimental stand for research and testing of the ACC startup at low temperatures is described. The design of the three-pass ACC unit is given, and its advantages over classical single-pass design at low temperatures are listed. The formation of ice plugs inside the heat exchanging tubes during the start-up of ACC and DCT at low cooling air temperatures is analyzed. Experimental data on the effect of the steam flow rate, steam nozzle distance from the heat-exchange surface, and their orientation in space on the metal temperature were collected, and test results are analyzed. It is noted that the surface temperature at the end of the heat up is almost independent from its initial temperature. Recommendations for the safe start-up of ACCs and DCTs are given. The heating flow necessary to sufficiently heat up heat-exchange surfaces of ACCs and DCTs for the safe startup is estimated. The technology and the process of the heat up of the ACC with the heating steam external supply are described by the example of the startup of the full-scale section of the ACC at sub-zero temperatures of the cooling air, and the advantages of the proposed start-up technology are confirmed.

  13. Artifact peroxides produced during cryogenic sampling of ambient air

    NASA Astrophysics Data System (ADS)

    Staffelbach, Thomas; Neftel, Albrecht; Dasgupta, Purnendu K.

    Peroxides were found to be produced as artifacts during cryogenic sampling with Horibe traps. Cryogenic trap sampling was compared to collection with a wet effluent diffusion denuder and a Nafion membrane diffusion denuder. Hydrogen peroxide and hydroxymethyl hydroperoxide measured in the cryogenic trap samples were significantly higher. In comparison, no evidence of artifact methyl hydroperoxide production was found. The amount of artifact H2O2 and HMHP produced increased with decreasing trap temperature. Spiking ambient air with ethene or isoprene showed that these hydrocarbons, in the presence of ozone, can be responsible for the artifact production of peroxides. Our results clearly suggest that the peroxide data obtained by cryogenic sampling and reported in the literature should be interpreted with caution.

  14. Investigation of drop impact on dry and wet surfaces with consideration of surrounding air

    NASA Astrophysics Data System (ADS)

    Guo, Yisen; Lian, Yongsheng; Sussman, Mark

    2016-07-01

    Numerical simulations were conducted to investigate drop impingement and splashing on both dry and wet surfaces at impact velocities greater than 50 m/s with the consideration of the effect of surrounding air. The Navier-Stokes equations were solved using the variable density pressure projection method on a dynamic block structured adaptive grid. The moment of fluid method was used to reconstruct interfaces separating different phases. A dynamic contact angle model was used to define the boundary condition at the moving contact line. Simulations showed that lowering the ambient gas density can suppress dry surface splashing, which is in agreement with the experiments. A recirculation zone was observed inside the drop after contact: a larger recirculation zone was formed earlier in the higher gas density case than in the lower gas density case. Increasing gas density also enhances the creation of secondary droplets from the lamella breakup. For high speed impact on a dry surface, lowering ambient gas density attenuates splashing. However, ambient air does not significantly affect splashing on a wet surface. Simulations showed that the splashed droplets are primarily from the exiting liquid film.

  15. Entrainment Rate in Shallow Cumuli: Dependence on Entrained Dry Air Sources and Probability Density Functions

    NASA Astrophysics Data System (ADS)

    Lu, C.; Liu, Y.; Niu, S.; Vogelmann, A. M.

    2012-12-01

    In situ aircraft cumulus observations from the RACORO field campaign are used to estimate entrainment rate for individual clouds using a recently developed mixing fraction approach. The entrainment rate is computed based on the observed state of the cloud core and the state of the air that is laterally mixed into the cloud at its edge. The computed entrainment rate decreases when the air is entrained from increasing distance from the cloud core edge; this is because the air farther away from cloud edge is drier than the neighboring air that is within the humid shells around cumulus clouds. Probability density functions of entrainment rate are well fitted by lognormal distributions at different heights above cloud base for different dry air sources (i.e., different source distances from the cloud core edge). Such lognormal distribution functions are appropriate for inclusion into future entrainment rate parameterization in large scale models. To the authors' knowledge, this is the first time that probability density functions of entrainment rate have been obtained in shallow cumulus clouds based on in situ observations. The reason for the wide spread of entrainment rate is that the observed clouds are affected by entrainment mixing processes to different extents, which is verified by the relationships between the entrainment rate and cloud microphysics/dynamics. The entrainment rate is negatively correlated with liquid water content and cloud droplet number concentration due to the dilution and evaporation in entrainment mixing processes. The entrainment rate is positively correlated with relative dispersion (i.e., ratio of standard deviation to mean value) of liquid water content and droplet size distributions, consistent with the theoretical expectation that entrainment mixing processes are responsible for microphysics fluctuations and spectral broadening. The entrainment rate is negatively correlated with vertical velocity and dissipation rate because entrainment

  16. Crystallization of spray-dried lactose/protein mixtures in humid air

    NASA Astrophysics Data System (ADS)

    Shawqi Barham, A.; Kamrul Haque, Md.; Roos, Yrjö H.; Kieran Hodnett, B.

    2006-10-01

    An in situ crystallization technique with X-ray diffraction analysis complemented by ex situ scanning electron microscopy and chromatographic analysis of the α/( α+ β) solid-state anomeric ratios has been developed to study the crystallization of lactose/protein mixtures in humid air. This technique was used to determine changes in phase composition and morphology during crystallization. Following an induction period during which water is sorbed, crystallization is rapid and the predominant phase observed using the in situ method in spray-dried lactose/sodium-caseinate, albumin and gelatin is α-lactose monohydrate. However, in the case of spray-dried lactose/whey protein isolate (WPI) the predominant phase that appears is the α/ β mixed phase with smaller amounts of α-lactose monohydrate. With pure lactose the α/ β mixed phase appears as a transient shortly after the onset of crystallization and α-lactose monohydrate and β-lactose both appear as stable crystalline phases at longer times. Another transient phase with 2 θ=12.2°, 20.7° and 21.8° was observed in spray-dried lactose/albumin. This phase decomposed as α-lactose monohydrate developed. Three phases seem to persist in the case of spray-dried lactose/gelatin, namely the phase with peaks at 2 θ=12.2°, 20.7° and 21.8°, α-lactose monohydrate and β-lactose for the duration of the in situ experiment.

  17. [Effect of air humidity on traditional Chinese medicine extract of spray drying process and prediction of its powder stability].

    PubMed

    He, Yan; Xie, Yin; Zheng, Long-jin; Liu, Wei; Rao, Xiao-yong; Luo, Xiao-jian

    2015-02-01

    In order to solve the adhesion and the softening problems of traditional Chinese medicine extract during spray drying, a new method of adding dehumidified air into spray drying process was proposed, and the storage stability conditions of extract powder could be predicted. Kouyanqing extract was taken as model drug to investigate on the wet air (RH = 70%) and dry air conditions of spray drying. Under the dry air condition, the influence of the spray drying result with different air compression ratio and the spray-dried powder properties (extract powder recovery rate, adhesion percentage, water content, angle of repose, compression ratio, particle size and distribution) with 100, 110, 120, 130, 140 °C inlet temperature were studied. The hygroscopic investigation and Tg value with different moisture content of ideal powder were determined. The water activity-equilibrium moisture content (aw-EMC) and the equilibrium moisture content-Tg (EMC-Tg) relationships were fitted by GAB equation and Gordon-Taylor model respectively, and the state diagram of kouyanqing powder was obtained to guide the rational storage conditions. The study found that in the condition of dry air, the extract powder water content decreased with the increase of air compression ratio and the spray drying effect with air compression ratio of 100% was the best performance; in the condition of wet air, the extract powder with high water content and low yield, and the value were 4.26% and 16.73 °C, while, in the dry air condition the values were 2.43% and 24.86 °C with the same other instru- ment parameters. From the analysis of kouyanqing powder state diagram, in order to keep the stability, the critical water content of 3.42% and the critical water content of 0.188. As the water decreased Tg value of extract powder is the major problem of causing adhesion and softening during spray drying, it is meaningful to aid dehumidified air during the process. PMID:26084164

  18. Ambient Air Sampling During Quantum-dot Spray Deposition

    SciTech Connect

    Jankovic, John Timothy; Hollenbeck, Scott M

    2010-01-01

    Ambient air sampling for nano-size particle emissions was performed during spot spray coating operations with a Sono-Tek Exactacoat Benchtop system (ECB). The ECB consisted of the application equipment contained within an exhaust enclosure. The enclosure contained numerous small access openings, including an exhaust hook-up. Door access comprised most of the width and height of the front. The door itself was of the swing-out type. Two types of nanomaterials, Cadmium selenide (Cd-Se) quantum-dots (QDs) and Gold (Au) QDs, nominally 3.3 and 5 nm in diameter respectively, were applied during the evaluation. Median spray drop size was in the 20 to 60 micrometer size range.1 Surface coating tests were of short duration, on the order of one-half second per spray and ten spray applications between door openings. The enclosure was ventilated by connection to a high efficiency particulate aerosol (HEPA) filtered house exhaust system. The exhaust rate was nominally 80 ft3 per minute producing about 5 air changes per minute. Real time air monitoring with a scanning mobility particle size analyzer (SMPS ) with a size detection limit of 7 nm indicated a significant increase in the ambient air concentration upon early door opening. A handheld condensation particle counter (CPC) with a lower size limit of 10 nm did not record changes in the ambient background. This increase in the ambient was not observed when door opening was delayed for 2 minutes (~10 air changes). The ventilated enclosure controlled emissions except for cases of rapid door opening before the overspray could be removed by the exhaust. A time delay sufficient to provide 10 enclosure air changes (a concentration reduction of more than 99.99 %) before door opening prevented the release of aerosol particles in any size.2 Scanning-transmission electron microscopy (STEM) and atomic force microscopy (AFM) demonstrated the presence of agglomerates in the surfaces of the spray applied deposition. A filtered air sample of

  19. Evaluation of official air sampling methodologies in Ukraine

    SciTech Connect

    Nakonechniy, J.J.; Wadden, R.A.; Scheff, P.A.; Suero, M.

    1997-12-31

    In conjunction with an environmental epidemiology study of the health of Ukrainian children, a significant amount of air pollution measurement data was gathered from government agencies. The areas of interest were the industrial city of Dneprodzherzhinsk; and the Dniprovsky region of Kyiv. The data were for 1993 and, for some of the monitoring stations, 1994. The pollutants reported included dust (approximately equivalent to TSP, total suspended particulate matter), SO{sub 2}, CO, NO{sub 2}, NO, H{sub 2}S, phenol, HCl, NH{sub 3}, formaldehyde, BaP, and lead. The ultimate goal was to evaluate whether existing historical data are appropriate for developing measures of human exposure. In order to evaluate the data it was necessary to understand the sampling and analytical methodologies which were used. Small sample volumes coupled with dated analytical procedures resulted in very poor precision and detection limits for most of the measured pollutants. The measurement of particulate matter is a good example of the limits imposed by the sampling methodology. The short sample time (20 min), small sample volume (150 lpm), and limited analytical balances (0.5 mg resolution) result in a minimum lower limit of detection of 0.25 mg/m{sup 3}. For example at Kyiv Station 3 in 1993, only one of 545 measurements exceeded 0.2 mg/m{sup 3}. This minimum detectable quantity is over three times the former US annual TSP standard. In addition, even when operated on a 24-hour basis in the US, it has been shown that the sampling method only collected approximately 34% of that collected by a co-located hi-vol sampler. Consequently, official air pollution data for suspended dust are likely to severely under-represent actual ambient concentrations. Data for other pollutants are presented and sampling and analytical methods are similarly compared with Western methods in common use.

  20. Investigation of microwave assisted drying of samples and evaporation of aqueous solutions in trace element analysis.

    PubMed

    Maichin, B; Kettisch, P; Knapp, G

    2000-01-01

    Investigations of microwave assisted drying of sample materials and microwave assisted evaporation of aqueous sample solutions and acidic digestion residues were accomplished by means of special rotors for the microwave digestion system MULTIWAVE. To check the results obtained by microwave assisted drying, the samples were also conventionally dried at 105 degrees C in an oven. The following samples have been dried: 10 g each of meat, fish, apple, cucumber, potato, mustard, yogurt, clay and marl; 1 g each of certified reference material TORT 2 (lobster hepatopancreas), BCR 278 (mussel tissue) and BCR 422 (cod muscle); 500 g garden mould. Microwave assisted drying takes 40 min for organic samples and 30 min for inorganic material. Important is a slow increase of microwave power during the first 20 min. The results agree well with conventional drying at 105 degrees C. Losses of As, Se and Hg have been investigated for 3 CRMs. Only Se shows losses in the range of 20%. Losses of As, Be, Cd, Co, Cr, Cu, Fe, Hg, Li, Mg, Mn, Mo, Ni, Pb, Sb, Se, Sr, Ti, Tl, V and Zn after evaporation of aqueous samples and acidic solutions after wet digestion, respectively, have been investigated. 50 mL aqueous solution was evaporated almost to dryness within 25 min. The recovery of Hg is 40-50%, of Se 90-95% and of the other elements 97-102%. 0.2 g each of TORT 2, BCR 278 and BCR 422 have been digested with 4 mL nitric acid and 1 mL hydrochloric acid by means of the microwave digestion system MULTIWAVE. The digestion residue was evaporated almost to dryness and dissolved again in 10 mL diluted nitric acid. In this case no element losses have been observed. The measured concentration of As, Cd, Cu, Fe, Mn, Hg, Pb, Mo, Ni, Se, Sr, V and Zn agree very well with the certified values. An important prerequisite for good recoveries is not to evaporate the solutions to complete dryness. PMID:11225810

  1. Passive air sampling of gaseous elemental mercury: a critical review

    NASA Astrophysics Data System (ADS)

    McLagan, David S.; Mazur, Maxwell E. E.; Mitchell, Carl P. J.; Wania, Frank

    2016-03-01

    Because gaseous elemental mercury (GEM) is distributed globally through the atmosphere, reliable means of measuring its concentrations in air are important. Passive air samplers (PASs), designed to be cheap, simple to operate, and to work without electricity, could provide an alternative to established active sampling techniques in applications such as (1) long-term monitoring of atmospheric GEM levels in remote regions and in developing countries, (2) atmospheric mercury source identification and characterization through finely resolved spatial mapping, and (3) the recording of personal exposure to GEM. An effective GEM PAS requires a tightly constrained sampling rate, a large and stable uptake capacity, and a sensitive analytical technique. None of the GEM PASs developed to date achieve levels of accuracy and precision sufficient for the reliable determination of background concentrations over extended deployments. This is due to (1) sampling rates that vary due to meteorological factors and manufacturing inconsistencies, and/or (2) an often low, irreproducible and/or unstable uptake capacity of the employed sorbents. While we identify shortcomings of existing GEM PAS, we also reveal potential routes to overcome those difficulties. Activated carbon and nanostructured metal surfaces hold promise as effective sorbents. Sampler designs incorporating diffusive barriers should be able to notably reduce the influence of wind on sampling rates.

  2. Passive air sampling of gaseous elemental mercury: a critical review

    NASA Astrophysics Data System (ADS)

    McLagan, D. S.; Mazur, M. E. E.; Mitchell, C. P. J.; Wania, F.

    2015-12-01

    Because gaseous elemental mercury (GEM) is distributed globally through the atmosphere, reliable means of measuring its concentrations in air are important. Passive air samplers (PASs), designed to be cheap, simple to operate, and to work without electricity, could provide an alternative to established active sampling techniques in applications such as (1) long term monitoring of atmospheric GEM levels in remote regions and in developing countries, (2) atmospheric mercury source identification and characterisation through finely-resolved spatial mapping, and (3) the recording of personal exposure to GEM. An effective GEM PAS requires a tightly constrained sampling rate, a large and stable uptake capacity, and a sensitive analytical technique. None of the GEM PASs developed to date achieves levels of accuracy and precision sufficient for the reliable determination of background concentrations over extended deployments. This is due to (1) sampling rates that vary due to meteorological factors and manufacturing inconsistencies and/or (2) an often low, irreproducible and/or unstable uptake capacity of the employed sorbents. While we identify shortcomings of existing GEM PAS, we also reveal potential routes to overcome those difficulties. Activated carbon and nano-structured metal surfaces hold promise as effective sorbents. Sampler designs incorporating diffusive barriers should be able to notably reduce the influence of wind on sampling rates.

  3. Optimization of the development process for air sampling filter standards

    NASA Astrophysics Data System (ADS)

    Mena, RaJah Marie

    Air monitoring is an important analysis technique in health physics. However, creating standards which can be used to calibrate detectors used in the analysis of the filters deployed for air monitoring can be challenging. The activity of a standard should be well understood, this includes understanding how the location within the filter affects the final surface emission rate. The purpose of this research is to determine the parameters which most affect uncertainty in an air filter standard and optimize these parameters such that calibrations made with them most accurately reflect the true activity contained inside. A deposition pattern was chosen from literature to provide the best approximation of uniform deposition of material across the filter. Samples sets were created varying the type of radionuclide, amount of activity (high activity at 6.4 -- 306 Bq/filter and one low activity 0.05 -- 6.2 Bq/filter, and filter type. For samples analyzed for gamma or beta contaminants, the standards created with this procedure were deemed sufficient. Additional work is needed to reduce errors to ensure this is a viable procedure especially for alpha contaminants.

  4. An experiment to determine atmospheric CO concentrations of tropical South Atlantic air samples

    NASA Astrophysics Data System (ADS)

    Kirchhoff, V. W. J. H.; Aires, C. B.; Alvala, P. C.

    2003-04-01

    New observations of atmospheric carbon monoxide, CO, are described, from tropical South Atlantic air samples. A new observational site, Maxaranguape, was set up in a clean remote environment right next to the ocean on the north-east coast of Brazil, to obtain CO mixing ratios and auxiliary data (meteorological parameters, ozone (O3), carbon dioxide (CO2) and methane (CH4)) during three sequential seasonal cycles. The seasonal variations of temperature, humidity and precipitation are shown for the new site. Chromatographic separation followed by mercury oxide detection is used to measure CO. The seasonality of the CO data was clearly established. Minima are seen during April, May and June showing wet-period averages of 56.1 parts per billion by volume (ppbv), with standard deviation 8.7 ppbv; during dry-period months, August to November, the average was 77.7 ± 16.5 ppbv. For comparison, CO concentrations were also measured over continental areas in Brazil. Much larger values have been found in moderate 'burning' regions, such as the south of the state of Mato Grosso and the north-western part of the state of Parana, where 200 ppbv in the dry season has been observed. Since normally the air masses have travelled for several days over the ocean, the air masses over the site present low chemical activity. Daily variations of CO2 are very small, of the order of a few percent relative to the diurnal mean. Only on rare occasions, when the wind direction changes, is the sampled air contaminated from flowing over the inhabited shoreline to the south, and then CO2 varies inversely with O3. The monthly mean CH4 data does not show a clear seasonal variation, possibly because the amplitude of the CH4 variation is only of the order of 1%, which is close to the precision of the measuring instrument.

  5. Tornado-type convection with moist ascending and dry descending air

    NASA Astrophysics Data System (ADS)

    Rutkevich, P. B.; Rutkevych, B. P.

    2010-05-01

    According to observations the tornado vortex in horizontal direction can be by convention divided into three parts: the internal part, the intermediate moist convective part and the surrounding part. In the convective part the moist air ascends and a big amount of latent heat is released which is the main energy source of formation and maintenance of the vortex. In the other parts of the structure takes place dissipation of this released energy. So in the second intermediate region the vertical temperature distribution is near to moist-adiabatic while in the other regions it is near to the dry- adiabatic. This leads to a complex convective process of the Ostroumov problem type infinite in horizontal direction with two vertical intermediate cylindrical boundaries. To find solution of such a problem it is necessary to make matching of the considered fields on these boundaries. This problem was considered with the use of Navier-Stokes equations and with the necessary matching at the boundaries. It was obtained that radial distribution of air flux depends on the stable vertical temperature distribution in the surrounding area. At strong stable stratification the vertical air velocity is maximal at the central part of the vortex and at weak stratification the almost neutrally stratified air is easily entrained upward by the strong vertical motion of the moist air in the second region.

  6. Sampling and analysis of terpenes in air. An interlaboratory comparison

    NASA Astrophysics Data System (ADS)

    Larsen, Bo; Bomboi-Mingarro, Teresa; Brancaleoni, Enzo; Calogirou, Aggelos; Cecinato, Angelo; Coeur, Cecile; Chatzinestis, Ioannis; Duane, Matthew; Frattoni, Massimiliano; Fugit, Jean-Luc; Hansen, Ute; Jacob, Veronique; Mimikos, Nikolaos; Hoffmann, Thorsten; Owen, Susan; Perez-Pastor, Rosa; Reichmann, Andreas; Seufert, Gunther; Staudt, Michael; Steinbrecher, Rainer

    An interlaboratory comparison on the sampling and analysis of terpenes in air was held within the framework of the BEMA (Biogenic Emissions in the Mediterranean Area) project in May 1995. Samples were drawn and analysed by 10 European laboratories from a dynamic artificial air generator in which five terpenes were present at low ng ℓ -1 levels and ozone varied between 8 and 125 ppbv. Significant improvements over previous inter-comparison exercises in the quality of results were observed. At the ozone mixing ratio of 8 ppbv a good agreement among laboratories was obtained for all test compounds with mean values close to the target concentration. At higher mixing ratios, ozone reduced terpene recoveries and decreased the precision of the measurements due to ozonolysis during sampling. For β-pinene this effect was negligible but for the more reactive compounds significant losses were observed in some laboratories ( cis-β-ocimene = trans-β-ocimene > linalool > d-limonene). The detrimental effect of ozone was significantly lower for the laboratories which removed ozone prior to sampling by scrubbers. Parallel sampling was carried out with a standardised sampler and each individual laboratory's own device. A good agreement between the two sets of results was obtained, clearly showing that the majority of laboratories used efficient sampling systems. Two different standard solutions were analysed by each laboratory. Only in a few cases did interference in the GC separation cause problems for the quantification of the terpenes (nonanal/linalool). However, making up of standards for the calibration of the analytical equipment (GC-MS or GC-FID) was pointed out as a source of error in some laboratories.

  7. CONVENIENT SAMPLING OF AIR BACTERIA IN OPERATING ROOMS.

    PubMed

    WARNER, P; GLASSCO, A; KROEKER, J

    1964-02-22

    A convenient arrangement for sampling air bacteria in operating rooms with a slit sampler (the Fort Detrick sampler) is described. Its purpose is to contribute as far as possible to the convenience of the surgical staff and thereby to the safety of the patient. It has the advantages of recording minute-to-minute changes in bacterial air count; it is unobtrusive and yet can be continually observed by a technician; it is not noisy and avoids the dangers of explosion and static electricity; it is inexpensive, and parts are easily replaced; and finally it provides a means of keeping permanent photographic records of bacterial counts. Results of a preliminary trial of this method appeared to be satisfactory. PMID:14118695

  8. Dry hair

    MedlinePlus

    ... or using harsh soaps or alcohols Excessive blow-drying Dry air Menkes kinky hair syndrome Malnutrition Underactive ... or twice a week Add conditioners Avoid blow drying and harsh styling products

  9. Dry hair

    MedlinePlus

    Some causes of dry hair are: Anorexia nervosa Excessive hair washing, or using harsh soaps or alcohols Excessive blow-drying Dry air Menkes kinky hair syndrome Malnutrition Underactive parathyroid ( ...

  10. Comparative study of denaturation of whey protein isolate (WPI) in convective air drying and isothermal heat treatment processes.

    PubMed

    Haque, M Amdadul; Aldred, Peter; Chen, Jie; Barrow, Colin J; Adhikari, Benu

    2013-11-15

    The extent and nature of denaturation of whey protein isolate (WPI) in convective air drying environments was measured and analysed using single droplet drying. A custom-built, single droplet drying instrument was used for this purpose. Single droplets having 5±0.1μl volume (initial droplet diameter 1.5±0.1mm) containing 10% (w/v) WPI were dried at air temperatures of 45, 65 and 80°C for 600s at constant air velocity of 0.5m/s. The extent and nature of denaturation of WPI in isothermal heat treatment processes was measured at 65 and 80°C for 600s and compared with those obtained from convective air drying. The extent of denaturation of WPI in a high hydrostatic pressure environment (600MPa for 600s) was also determined. The results showed that at the end of 600s of convective drying at 65°C the denaturation of WPI was 68.3%, while it was only 10.8% during isothermal heat treatment at the same medium temperature. When the medium temperature was maintained at 80°C, the denaturation loss of WPI was 90.0% and 68.7% during isothermal heat treatment and convective drying, respectively. The bovine serum albumin (BSA) fraction of WPI was found to be more stable in the convective drying conditions than β-lactoglobulin and α-lactalbumin, especially at longer drying times. The extent of denaturation of WPI in convective air drying (65 and 80°C) and isotheral heat treatment (80°C) for 600s was found to be higher than its denaturation in a high hydrostatic pressure environment at ambient temperature (600MPa for 600s). PMID:23790837

  11. Relative Humidity and its Effect on Sampling and Analysis of Agricultural Odorants in Air

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Source and ambient air sampling techniques used in agricultural air quality studies are seldom validated for the variability in the air matrix (temperature, dust levels, and relative humidity). In particular, relative humidity (RH) affects both field sampling and analysis of air samples. The objec...

  12. Cold, dry air is associated with influenza and pneumonia mortality in Auckland, New Zealand.

    PubMed

    Davis, Robert E; Dougherty, Erin; McArthur, Colin; Huang, Qiu Sue; Baker, Michael G

    2016-07-01

    The relationship between weather and influenza and pneumonia mortality was examined retrospectively using daily data from 1980 to 2009 in Auckland, New Zealand, a humid, subtropical location. Mortality events, defined when mortality exceeded 0·95 standard deviation above the mean, followed periods of anomalously cold air (ta.m. = -4·1, P < 0·01; tp.m. = -4·2, P < 0·01) and/or anomalously dry air (ta.m. = -4·1, P < 0·01; tp.m. = -3·8, P < 0·01) by up to 19 days. These results suggest that respiratory infection is enhanced during unusually cold conditions and during conditions with unusually low humidity, even in a subtropical location where humidity is typically high. PMID:26681638

  13. Effect of temperature and air velocity on drying kinetics, antioxidant capacity, total phenolic content, colour, texture and microstructure of apple (var. Granny Smith) slices.

    PubMed

    Vega-Gálvez, Antonio; Ah-Hen, Kong; Chacana, Marcelo; Vergara, Judith; Martínez-Monzó, Javier; García-Segovia, Purificación; Lemus-Mondaca, Roberto; Di Scala, Karina

    2012-05-01

    The aim of this work was to study the effect of temperature and air velocity on the drying kinetics and quality attributes of apple (var. Granny Smith) slices during drying. Experiments were conducted at 40, 60 and 80°C, as well as at air velocities of 0.5, 1.0 and 1.5ms(-1). Effective moisture diffusivity increased with temperature and air velocity, reaching a value of 15.30×10(-9)m(2)s(-1) at maximum temperature and air velocity under study. The rehydration ratio changed with varying both air velocity and temperature indicating tissue damage due to processing. The colour difference, ΔE, showed the best results at 80°C. The DPPH-radical scavenging activity at 40°C and 0.5ms(-1) showed the highest antioxidant activity, closest to that of the fresh sample. Although ΔE decreased with temperature, antioxidant activity barely varied and even increased at high air velocities, revealing an antioxidant capacity of the browning products. The total phenolics decreased with temperature, but at high air velocity retardation of thermal degradation was observed. Firmness was also determined and explained using glass transition concept and microstructure analysis. PMID:26434262

  14. Evaluation of Urban Air Quality By Passive Sampling Technique

    NASA Astrophysics Data System (ADS)

    Nunes, T. V.; Miranda, A. I.; Duarte, S.; Lima, M. J.

    Aveiro is a flat small city in the centre of Portugal, close to the Atlantic coast. In the last two decades an intensive development of demographic, traffic and industry growth in the region was observed which was reflected on the air quality degrada- tion. In order to evaluate the urban air quality in Aveiro, a field-monitoring network by passive sampling with high space resolution was implemented. Twenty-four field places were distributed in a area of 3x3 Km2 and ozone and NO2 concentrations were measured. The site distribution density was higher in the centre, 250x250 m2 than in periphery where a 500x500 m2 grid was used. The selection of field places took into consideration the choice criteria recommendation by United Kingdom environmental authorities, and three tubes and a blank tube for each pollutant were used at each site. The sampling system was mounted at 3m from the ground usually profiting the street lampposts. Concerning NO2 acrylic tubes were used with 85 mm of length and an in- ternal diameter of 12mm, where in one of the extremities three steel grids impregnated with a solution of TEA were placed and fixed with a polyethylene end cup (Heal et al., 1999); PFA Teflon tube with 53 mm of length and 9 mm of internal diameter and three impregnated glass filters impregnated with DPE solution fixed by a teflon end cup was used for ozone sampling (Monn and Hargartner, 1990). The passive sampling method for ozone and nitrogen dioxide was compared with continuous measurements, but the amount of measurements wasnSt enough for an accurate calibration and validation of the method. Although this constraint the field observations (June to August 2001) for these two pollutants assign interesting information about the air quality in the urban area. A krigger method of interpolation (Surfer- Golden Software-2000) was applied to field data to obtain isolines distribution of NO2 and ozone concentration for the studied area. Even the used passive sampling method has many

  15. [Blood sampling using "dried blood spot": a clinical biology revolution underway?].

    PubMed

    Hirtz, Christophe; Lehmann, Sylvain

    2015-01-01

    Blood testing using the dried blood spot (DBS) is used since the 1960s in clinical analysis, mainly within the framework of the neonatal screening (Guthrie test). Since then numerous analytes such as nucleic acids, small molecules or lipids, were successfully measured on the DBS. While this pre-analytical method represents an interesting alternative to classic blood sampling, its use in routine is still limited. We review here the different clinical applications of the blood sampling on DBS and estimate its future place, supported by the new methods of analysis as the LC-MS mass spectrometry. PMID:25582720

  16. Listeria monocytogenes strains isolated from dry milk samples in Mexico: occurrence and antibiotic sensitivity.

    PubMed

    Rodas-Suárez, O R; Quiñones-Ramírez, E I; Fernández, F J; Vázquez-Salinas, C

    2013-09-01

    Dry milk is a particular concern in Mexico, as approximately 150,000 metric tons of dry milk are imported every year at a cost of around $250 million. Dry milk is used to make many products, most of which are dairy products widely distributed among the population covered by welfare programs. The purpose of the study described in this article was to determine the presence of Listeria spp. in imported dry milk samples in Mexico, and to determine the sensitivity of the Listeria monocytogenes isolates to different antimicrobial agents. Listeria isolates (7.8% of 550 bacterial isolates) were identified as L. monocytogenes (53.49%), L. innocua (30.23%), L. seeligeri (13.95%), and L. ivanovii (2.33%). L. monocytogenes strains isolated showed multiresistance to ampicillin, erythromycin, tetracycline, dicloxacillin, and trimethoprim-sulfamethoxazole (9%-14%). The results provide additional evidence of the emergence of multiresistant Listeria strains both in nature and in widely consumed dairy products, representing a potential threat to human health. PMID:24073487

  17. 13c Measurements On Air of Small Ice Samples

    NASA Astrophysics Data System (ADS)

    Eyer, M.; Leuenberger, M.

    We have developed a new method for 13C analysis for very small air amounts of less than 0.5 cc STP, corresponding to less than 10 gram of ice. It is based on the needle-crasher technique, which we routinely use for CO2 concentration measurements by infrared laser absorption. The extracted air is slowly expanded into a large volume through a water trap held at ­100°C. This sampled air is then carried by a high helium flux through a modified Precon system of Thermo-Finnigan to separate CO2 from the air and to inject the pure CO2 gas in a low helium stream via an open split device to a Delta Plus XL mass spectrometer. The overall precision based on replicates of standard air is significantly better than 0.1 for a single analysis and is further improved by a triplicate measurement of the same sample through a specially designed gas splitter. We have used this new method for investigations on polar ice cores. The 13C measurements are important for climate reconstructions, e.g. to reconstruct the evolution and its variability in the terrestrial and oceanic carbon sinks and to identify natural variations in the marine carbon cycle. During the industrialization atmospheric 13C decreased by about -2, mainly due to the anthropogenic release of biogenic CO2 by fossil fuel burning. Reconstructions of carbon and oxygen cycles of Joos at al. [1999] using a double deconvolution method show that between 1930 and 1950 the net terrestrial release is changing to a net terrestrial uptake of CO2. A highly resolved 13C dataset of this time window would replenish the documentation of this behaviour. Further, it would be interesting to compare such data with O2/N2 measurements, known as an other partitioning tool for carbon sources and sinks. At the EGS 2002 we will present a highly resolved 13C record from Antarctic ice covering this time period.

  18. Ozone measurement system for NASA global air sampling program

    NASA Technical Reports Server (NTRS)

    Tiefermann, M. W.

    1979-01-01

    The ozone measurement system used in the NASA Global Air Sampling Program is described. The system uses a commercially available ozone concentration monitor that was modified and repackaged so as to operate unattended in an aircraft environment. The modifications required for aircraft use are described along with the calibration techniques, the measurement of ozone loss in the sample lines, and the operating procedures that were developed for use in the program. Based on calibrations with JPL's 5-meter ultraviolet photometer, all previously published GASP ozone data are biased high by 9 percent. A system error analysis showed that the total system measurement random error is from 3 to 8 percent of reading (depending on the pump diaphragm material) or 3 ppbv, whichever are greater.

  19. Dry Pressed Holey Graphene Composites for Li-air Battery Cathodes

    NASA Astrophysics Data System (ADS)

    Lacey, Steven; Lin, Yi; Hu, Liangbing

    Graphene is considered an ``omnipotent'' material due to its unique structural characteristics and chemical properties. By heating graphene powder in an open-ended tube furnace, a novel compressible carbon material, holey graphene (hG), can be created with controlled porosity and be further decorated with nanosized catalysts to increase electrocatalytic activity. All hG-based materials were characterized using various microscopic and spectroscopic techniques to obtain morphological, topographical, and chemical information as well as to identify any disordered/crystalline phases. In this work, an additive-free dry press method was employed to press the hG composite materials into high mass loading mixed, sandwich, and double-decker Li-air cathode architectures using a hydraulic press. The sandwich and double-decker (i.e. Big Mac) cathode architectures are the first of its kind and can be discharged for more than 200 hours at a current density of 0.2 mA/cm2. The scalable, binderless, and solventless dry press method and unique Li-air cathode architectures presented here greatly advance electrode fabrication possibilities and could promote future energy storage advancements. Support appreciated from the NASA Internships Fellowships Scholarships (NIFS) Program.

  20. Simple Freeze-Drying Procedure for Producing Nanocellulose Aerogel-Containing, High-Performance Air Filters.

    PubMed

    Nemoto, Junji; Saito, Tsuguyuki; Isogai, Akira

    2015-09-01

    Simple freeze-drying of 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO)-oxidized cellulose nanofibril (TOCN) dispersions in water/tert-butyl alcohol (TBA) mixtures was conducted to prepare TOCN aerogels as high-performance air filter components. The dispersibility of the TOCNs in the water/TBA mixtures, and the specific surface area (SSA) of the resulting TOCN aerogels, was investigated as a function of the TBA concentration in the mixtures. The TOCNs were homogeneously dispersed in the water/TBA mixtures at TBA concentrations up to 40% w/w. The SSAs of the TOCN aerogels exceeded 300 m2/g when the TBA concentration in the aqueous mixtures was in the range from 20% to 50% w/w. When a commercially available, high-efficiency particulate air (HEPA) filter was combined with TOCN/water/TBA dispersions prepared using 30% TBA, and the product was freeze-dried, the resulting TOCN aerogel-containing filters showed superior filtration properties. This was because nanoscale, spider-web-like networks of the TOCNs with large SSAs were formed within the filter. PMID:26301859

  1. Determination of Total Glutathione in Dried Blood Spot Samples Using a High-Performance Liquid Chromatography.

    PubMed

    Kanďár, Roman; Štramová, Xenie; Drábková, Petra; Brandtnerová, Martina

    2015-07-01

    A method is described for the determination of total glutathione (TGSH) in dried blood spot (DBS) samples using high-performance liquid chromatography with fluorescence detection. Whole blood and DBS samples were obtained from a group of blood donors. After GSH reduction with dithiothreitol and protein precipitation with ethanol, the samples were derivatized with naphthalene-2,3-dicarboxaldehyde to form a very stable, highly fluorescent derivative. For the separation, a reversed phase HPLC method was used. The mixture of ethanol and deionized water (8 : 92, v/v) was used as a mobile phase. The analytical performance of this method was satisfactory: the intra- and interassay coefficients of variation were below 10%. Quantitative recoveries from spiked DBS samples were between 98.3 and 103.6%. The presented method is inexpensive and suitable for clinical testing purposes. PMID:25344838

  2. Bioanalysis of dried saliva spot (DSS) samples using detergent-assisted sample extraction with UHPLC-MS/MS detection.

    PubMed

    Zheng, Naiyu; Zeng, Jianing; Ji, Qin C; Angeles, Aida; Aubry, Anne-Francoise; Basdeo, Shenita; Buzescu, Adela; Landry, Ishani Savant; Jariwala, Navin; Turley, Wesley; Burrell, Richard; Arnold, Mark E

    2016-08-31

    Dried saliva spot (DSS) sampling is a non-invasive sample collection technique for bioanalysis that can be potentially implemented at the patient's home. A UHPLC-MS/MS assay was developed using detergent-assisted sample extraction to quantify BMS-927711, a drug candidate in development for the treatment of migraines, in human DSS. By implementing DSS sampling at the patients' home, the bioanalytical sample collection for pharmacokinetic evaluation can be done at the time of the acute migraine attack without the need for clinical visits. DSS samples were prepared by spotting 15 μL of liquid saliva onto regular Whatman FTA™ DMPK-C cards and verified with a UV lamp (at λ 254 nm or 365 nm) during DSS punching. The 4-mm DSS punches in a 96-well plate were sonicated with 200 μL of [(13)C2, D4]-BMS-927711 internal standard (IS) solution in 20/80 MeOH/water for 10 min, followed by sonication with 50 μL of 100 mM NH4OAc with 1.0% Triton-X-100 (as detergent) prior to liquid-liquid extraction with 600 μL EtOAc/Hexane (90:10). UHPLC-MS/MS was performed with an Aquity(®) UPLC BEH C18 Column (2.1 × 50 mm, 1.7 μm) on a Triple Quad™ 5500 mass spectrometer. The assay was linear with a concentration range from 2.00 to 1000 ng mL(-1) for BMS-927711 in human saliva. The intra- and inter-assay precision was within 8.8% CV, and the accuracy was within ±6.7% Dev of the nominal concentration values. This UHPLC-MS/MS assay has been successfully applied to determine the drug's pharmacokinetics within a clinical study. For the first time, we observed BMS-927711 exposure in human DSS, confirming the suitability of this sampling technique for migraine patients to use at home. Detergent-assisted extraction with Triton-X-100 could be very useful in DSS or other dried matrix spot (DMS) assays to overcome low or inconsistent analyte recovery issues. PMID:27506357

  3. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples.

    PubMed

    Skogstrand, Kristin; Ekelund, Charlotte K; Thorsen, Poul; Vogel, Ida; Jacobsson, Bo; Nørgaard-Pedersen, Bent; Hougaard, David M

    2008-07-20

    The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7, and 30 days at the same temperatures. 27 inflammatory markers in serum and plasma and 25 markers in DBSS were measured by a previously validated multiplex sandwich immunoassay using Luminex xMAP technology. The measurable concentrations of several cytokines in serum and plasma were significantly increased when blood samples were stored for a period of time before the centrifugation, for certain cytokines more than 1000 fold compared to serum and plasma isolated and frozen immediately after venepuncture. The concentrations in serum generally increased more than in plasma. The measurable concentrations of inflammatory markers also changed in DBSS stored under various conditions compared to controls frozen immediately after preparation, but to a much lesser degree than in plasma or serum. The study demonstrates that trustworthy measurement of several inflammatory markers relies on handling of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood. PMID:18495149

  4. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 6 2011-07-01 2011-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA...

  5. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA...

  6. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 6 2012-07-01 2012-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA...

  7. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 6 2014-07-01 2014-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA...

  8. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA processing documents. (a) This section...

  9. Effect of air flow rate on the polyphenols content and antioxidant capacity of convective dried cactus pear cladodes (Opuntia ficus indica).

    PubMed

    Gallegos-Infante, José-Alberto; Rocha-Guzman, Nuria-Elizabeth; González-Laredo, Ruben-Francisco; Reynoso-Camacho, Rosalia; Medina-Torres, Luis; Cervantes-Cardozo, Veronica

    2009-01-01

    The interest in nopal has encouraged the use of dehydration; there are few studies about the effect of process parameters on the nopal polyphenol content and antioxidant activity. The objective of the present work was to evaluate the effect of air-drying flow rates on the amount and antioxidant capacity of extracts of Opuntia ficus indica cladodes. Nopal was dried at 45 degrees C and air flow rates of 3 and 5 m/sec. Samples were analyzed for moisture, total polyphenol, flavonoid, and flavonol contents, chain-breaking activity, inhibition of low-density lipoprotein and deoxyribose oxidation. Nopal drying at an air flow rate of 3 m/sec showed higher values of phenols, flavonoids and flavonols. The best value of low-density lipoprotein inhibition and deoxyribose was found at 1,000 microg/ml. The air flow rate affected the amount of polyphenols and the OH( . ) radical scavenging, but did not modify the chain-breaking activity and the low-density lipoprotein inhibition activity. PMID:19468951

  10. Effectiveness of Air Drying and Magnification Methods for Detecting Initial Caries on Occlusal Surfaces Using Three Different Diagnostic Aids.

    PubMed

    Goel, Deepti; Sandhu, Meera; Jhingan, Pulkit; Sachdev, Vinod

    2016-01-01

    Objective-The aim of this study was to assess the effect of magnification and air-drying on detection of carious lesion. Study Design-44 human extracted premolars were selected with sound occlusal surfaces without frank cavitation. The Diagnostic techniques used were Unaided visual examination, Magnifying Loupes (4.2×) and Stereomicroscope (10×, before and after air-drying) and then the teeth were sectioned bucco-lingually and both the surfaces were examined under Stereomicroscope (50×) to assess the presence or absence of carious lesion in the pit and fissures. The scores were compared to obtain Cohen's kappa coefficient (Reproducibility) and subjected to the Friedman Test and Paired t test. Sensitivity, specificity and positive predictive value used to assess accuracy. Results-On Statistical analysis, visual examination before and after air drying had highest specificity but lowest sensitivity compared to different diagnostic techniques. Magnifying loupes after air-drying had highest sensitivity and lowest specificity compared to other diagnostic techniques. Conclusion-Air drying combined with magnifying aids are cost-effective, reliable method for detection of early carious lesion. If used in pediatric clinical practice, any undesirable pain and discomfort to the patient due to invasive procedures and helps in employing preventive measures. PMID:27472570

  11. Bias in air sampling techniques used to measure inhalation exposure.

    PubMed

    Cohen, B S; Harley, N H; Lippmann, M

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and "mini hi-volume" samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. We conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages. PMID:6720582

  12. Bias in air sampling techniques used to measure inhalation exposure

    SciTech Connect

    Cohen, B.S.; Harley, N.H.; Lippmann, M.

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and mini hi-volume samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. The authors conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages.

  13. GEMAS: Colours of dry and moist agricultural soil samples of Europe

    NASA Astrophysics Data System (ADS)

    Klug, Martin; Fabian, Karl; Reimann, Clemens

    2016-04-01

    High resolution HDR colour images of all Ap samples from the GEMAS survey were acquired using a GeoTek Linescan camera. Three measurements of dry and wet samples with increasing exposure time and increasing illumination settings produced a set of colour images at 50μm resolution. Automated image processing was used to calibrate the six images per sample with respect to the synchronously measured X-Rite colorchecker chart. The calibrated images were then fit to Munsell soil colours that were measured in the same way. The results provide overview maps of dry and moist European soil colours. Because colour is closely linked to iron mineralogy, carbonate, silicate and organic carbon content the results can be correlated to magnetic, mineralogical, and geochemical properties. In combination with the full GEMAS chemical and physical measurements, this yields a valuable data set for calibration and interpretation of visible satellite colour data with respect to chemical composition and geological background, soil moisture, and soil degradation. This data set will help to develop new methods for world-wide characterization and monitoring of agricultural soils which is essential for quantifying geologic and human impact on the critical zone environment. It furthermore enables the scientific community and governmental authorities to monitor consequences of climatic change, to plan and administrate economic and ecological land use, and to use the data set for forensic applications.

  14. GAS CHROMATOGRAPHY/MATRIX ISOLATION - INFRARED SPECTROMETRY FOR AIR SAMPLE ANALYSIS

    EPA Science Inventory

    This report describes the application of gas chromatography/matrix- solation infrared (GC/MI-IR) spectrometry to the analysIs of environmental air sample extracts. Samples that were analyzed include extracts from woodsmoke-impacted air, XAD-2 blanks, indoor air, and carpet sample...

  15. Relationship among shock-wave velocity, particle velocity, and adiabatic exponent for dry air

    NASA Astrophysics Data System (ADS)

    Kim, In H.; Hong, Sang H.; Jhung, Kyu S.; Oh, Ki-Hwan; Yoon, Yo K.

    1991-07-01

    Using the results of the detailed numerical calculations, it is shown that the relationship between the shock-wave velocity U sub s and the particle velocity U sub p for shock-compressed dry air can be represented accurately by the linear relation U sub s = a(P0) + b(P0)U sub p in a wide range of U sub p (U sub p = 2 to 9 ) km/s and initial pressure P0 = 10 to the -6th to 1 atm, where a and b are given by the cubic polynomials of log10P0. Based on the linear U sub s - U sub p relation, an analytic expression has been obtained for the adiabatic exponent gamma as a function of particle velocity.

  16. [Determination of Trace Germanium in Plant Samples by Dry Ashing-Atomic Fluorescence Spectrometry].

    PubMed

    Chen, Hai-jie; Yu, Zhao-shui; Bai, Jin-feng; Li, Qing-xia; Liu, Ya-xuan; Bo, Wei; Zhang, Qin

    2015-04-01

    To reduce the limit of detection (LOD) and allow the accurate determination of Ge, a dry ashing method was performed to enrich the Ge in plant samples. A method for the determination.of trace Ge in plant samples by HG-AFS was established. Study of the effect of temperature on the ashing of plant samples showed that no volatile loss of Ge occurred even at 900 °C. Additional experiments indicated that a 4 h burning process at 600 °C would be sufficient to fully ash the plant samples. Various digestion methods (involving nitric acid, hydrofluoric acid, and sulfuric acid digestion methods) for ashed samples were investigated. High-temperature ashing with large sample weights was used, which could reduce the reagent doses and the method's LOD effectively and simultaneously, the precision of the method was improved. The method's LOD was 0.27 ng · g(-1), and the relative standard deviation was 3.99%-6.81%. Verified with national biological reference materials (grade I), the proposed method was accurate and reliable. PMID:26197600

  17. Transmission of Curing Light through Moist, Air-Dried, and EDTA Treated Dentine and Enamel

    PubMed Central

    Uusitalo, E.; Varrela, J.; Lassila, L.; Vallittu, P. K.

    2016-01-01

    Objective. This study measured light transmission through enamel and dentin and the effect of exposed dentinal tubules to light propagation. Methods. Light attenuation through enamel and dentin layers of various thicknesses (1 mm, 2 mm, 3 mm, and 4 mm) was measured using specimens that were (1) moist and (2) air-dried (n = 5). Measurements were repeated after the specimens were treated with EDTA. Specimens were transilluminated with a light curing unit (maximum power output 1869 mW/cm2), and the mean irradiance power of transmitting light was measured. The transmission of light through teeth was studied using 10 extracted intact human incisors and premolars. Results. Transmitted light irradiance through 1 mm thick moist discs was 500 mW/cm2 for enamel and 398 mW/cm2 for dentin (p < 0.05). The increase of the specimen thickness decreased light transmission in all groups (p < 0.005), and moist specimens attenuated light less than air-dried specimens in all thicknesses (p < 0.05). EDTA treatment increased light transmission from 398 mW/cm2 to 439 mW/cm2 (1 mm dentin specimen thickness) (p < 0.05). Light transmission through intact premolar was 6.2 mW/cm2 (average thickness 8.2 mm) and through incisor was 37.6 mW/cm2 (average thickness 5.6 mm). Conclusion. Light transmission through enamel is greater than that through dentin, probably reflecting differences in refractive indices and extinction coefficients. Light transmission through enamel, dentin, and extracted teeth seemed to follow Beer-Lambert's law. PMID:27446954

  18. Experimental evaluation of dry/wet air-cooled heat exchangers. Progress report

    SciTech Connect

    Hauser, S.G.; Gruel, R.L.; Huenefeld, J.C.; Eschbach, E.J.; Johnson, B.M.; Kreid, D.K.

    1982-08-01

    The ultimate goal of this project was to contribute to the development of improved cooling facilities for power plants. Specifically, the objective during FY-81 was to experimentally determine the thermal performance and operating characteristics of an air-cooled heat exchanger surface manufactured by the Unifin Company. The performance of the spiral-wound finned tube surface (Unifin) was compared with two inherently different platefin surfaces (one developed by the Trane Co. and the other developed by the HOETERV Institute) which were previously tested as a part of the same continuing program. Under dry operation the heat transfer per unit frontal area per unit inlet temperature difference (ITD) of the Unifin surface was 10% to 20% below that of the other two surfaces at low fan power levels. At high fan power levels, the performances of the Unifin and Trane surfaces were essentially the same, and 25% higher than the HOETERV surface. The design of the Unifin surface caused a significantly larger air-side pressure drop through the heat exchanger both in dry and deluge operation. Generally higher overall heat transfer coefficients were calculated for the Unifin surface under deluged operation. They ranged from 2.0 to 3.5 Btu/hr-ft/sup 2/-/sup 0/F as compared to less than 2.0 Btu hr-ft/sup 2/-/sup 0/F for the Trane and HOETERV surfaces under similar conditions. The heat transfer enhancement due to the evaporative cooling effect was also measureably higher with the Unifin surface as compared to the Trane surface. This can be primarily attributed to the better wetting characteristics of the Unifin surface. If the thermal performance of the surfaces are compared at equal face velocities, the Unifin surface is as much as 35% better. This method of comparison accounts for the wetting characteristics while neglecting the effect of pressure drop. Alternatively the surfaces when compared at equal pressure drop essentially the same thermal performance.

  19. Air-dense medium fluidized bed dry beneficiation of coal: Results of 50 MTPH demonstration plant

    SciTech Connect

    Chen Qingru; Yang Yi; Liang Chuncheng; Tao Xiuxiang; Luo Zhenfu

    1993-12-31

    This paper presents the performance results of the 50 MTPH Coal Dry Beneficiation Demonstration Plant constructed in the Heilongjiang Province of northeastern China. The separating media used in this process consists of an air/dense medium (magnetite, or magnetic pearls, a remnant of coal combustion in power plants) fluidized bed controllable at specific gravities ranging from 1.3 to 2.0. That portion of the feedstock with a specific gravity less than the separating gravity floats to the top of the fluidized bed where it is recovered at one end of the vessel. That portion of the feedstock with a specific gravity higher than the separating gravity sinks and is discharged from the other end of the vessel. The process has separating efficiencies similar to a heavy media vessel or cyclone with the additional advantages of (1) can be utilized in an arid region containing insufficient water supply, (2) results in a dry product requiring no additional dewatering and coal slime treatment, and (3) as result of air flow will remove some surface moisture present in the feedstock. As a result of the magnetite used in the fluidized bed and the subsequent downstream recovery of this magnetite, the current demonstration plant utilizes a 6mm bottom size. The topsize of the feed is a function of the size of the system and the site specific ash liberation requirement. The Demonstration Plant commenced operation in September 1992. The mechanical processes of the system including coal feeding, sizing, gravity separation/beneficiation, and medium recovery, functioned as anticipated from the 10 MTPH pilot plant. Preliminary results with separating gravities in the range of 1.3--2.0 showed a probable error as low as 0.05 with magnetite losses of 0.5 kg/MT of feed.

  20. Effect of dry warm air on respiratory water loss in children with exercise-induced asthma.

    PubMed

    Tabka, Z; Ben Jebria, A; Vergeret, J; Guenard, H

    1988-07-01

    The variation in respiratory water loss (RWL) over time, expressed as the mass of water vapor lost per liter (body temperature and pressure, saturated) of ventilation (MH2O), was investigated in two groups: (1) children with exercise-induced asthma; and (2) healthy children. Children were matched for age and sex and went without medication for at least 12 hours before each experiment. The children breathed dry warm air (TI = 28.4 degrees C +/- 0.3 degree C) for 15 minutes while bicycling at constant and moderate work load (50 W). The MH2O was measured by collecting and weighing the expired water vapor (1) at rest breathing in warm conditions of inspired gas (control values), (2) every five minutes during exercise while breathing dry warm air, and (3) four minutes after the end of exercise. Pulmonary function tests were performed before and six minutes after exercise. The results were abnormal only in children with exercise-induced asthma. During exercise, RWL significantly fell (compared to control value) at the tenth and 15th minute in both groups. Whereas normal subjects recovered their initial values for MH2O four minutes after stopping exercise, asthmatic children still had a reduction in respiratory water loss. During exercise, MH2O decreased a little more in healthy than in asthmatic children. The decrease in MH2O in both groups suggests that the means to fully humidify expired gas are overwhelmed by thermal stress. The lack of increase in MH2O in asthmatic children on stopping exercise suggests that the airway mucosa is unable to produce enough water vapor and is thus dehydrated and probably hyperosmotic. PMID:3383660

  1. Freeze-Drying as Sample Preparation for Micellar Electrokinetic Capillary Chromatography – Electrochemical Separations of Neurochemicals in Drosophila Brains

    PubMed Central

    Berglund, E. Carina; Kuklinski, Nicholas J.; Karagündüz, Ekin; Ucar, Kubra; Hanrieder, Jörg; Ewing, Andrew G.

    2013-01-01

    Micellar electrokinetic capillary chromatography with electrochemical detection has been used to quantify biogenic amines in freeze-dried Drosophila melanogaster brains. Freeze drying samples offers a way to preserve the biological sample while making dissection of these tiny samples easier and faster. Fly samples were extracted in cold acetone and dried in a rotary evaporator. Extraction and drying times were optimized in order to avoid contamination by red-pigment from the fly eyes and still have intact brain structures. Single freeze-dried fly-brain samples were found to produce representative electropherograms as a single hand-dissected brain sample. Utilizing the faster dissection time that freeze drying affords, the number of brains in a fixed homogenate volume can be increased to concentrate the sample. Thus, concentrated brain samples containing five or fifteen preserved brains were analyzed for their neurotransmitter content, and five analytes; dopamine N-acetyloctopamine, Nacetylserotonin, N-acetyltyramine, N-acetyldopamine were found to correspond well with previously reported values. PMID:23387977

  2. Passive Samplers for Investigations of Air Quality: Method Description, Implementation, and Comparison to Alternative Sampling Methods

    EPA Science Inventory

    This Paper covers the basics of passive sampler design, compares passive samplers to conventional methods of air sampling, and discusses considerations when implementing a passive sampling program. The Paper also discusses field sampling and sample analysis considerations to ensu...

  3. Sampling of air streams and incorporation of samples in the Microtox{trademark} toxicity testing system

    SciTech Connect

    Kleinheinz, G.T.; St. John, W.P.

    1997-10-01

    A study was conducted to develop a rapid and reliable method for the collection and incorporation of biofiltration air samples containing volatile organic compounds (VOCs) into the Microtox toxicity testing system. To date, no method exists for this type of assay. A constant stream of VOCs was generated by air stripping compounds from a complex mixture of petroleum hydrocarbons (PHCs). Samples were collected on coconut charcoal ORBO tubes and the VOCs extracted with methylene chloride. The compounds extracted were then solvent exchanged into dimethyl sulfoxide (DMSO) under gaseous nitrogen. The resulting DMSO extract was directly incorporated into the Microtox toxicity testing system. In order to determine the efficiency of the solvent exchange, the VOCs in the DMSO extract were then extracted into hexane and subsequently analyzed using gas chromatography (GC) with a flame ionization detector (FID). It was determined that all but the most volatile VOCs could be effectively transferred from the ORBO tubes to DMSO for Microtox testing. Potential trace amounts of residual methylene chloride in the DMSO extracts showed no adverse effects in the Microtox system when compared to control samples.

  4. High Efficiency Liquid-Desiccant Regenerator for Air Conditioning and Industrial Drying

    SciTech Connect

    Andrew Lowenstein

    2005-12-19

    Over 2 quads of fossil fuels are used each year for moisture removal. This includes industrial and agricultural processes where feedstocks and final products must be dried, as well as comfort conditioning of indoor spaces where the control of humidity is essential to maintaining healthy, productive and comfortable working conditions. Desiccants, materials that have a high affinity for water vapor, can greatly reduce energy use for both drying and dehumidification. An opportunity exists to greatly improve the competitiveness of advanced liquid-desiccant systems by increasing the efficiency of their regenerators. It is common practice within the chemical process industry to use multiple stage boilers to improve the efficiency of thermal separation processes. The energy needed to regenerate a liquid desiccant, which is a thermal separation process, can also be reduced by using a multiple stage boiler. In this project, a two-stage regenerator was developed in which the first stage is a boiler and the second stage is a scavenging-air regenerator. The only energy input to this regenerator is the natural gas that fires the boiler. The steam produced in the boiler provides the thermal energy to run the second-stage scavenging-air regenerator. This two-stage regenerator is referred to as a 1?-effect regenerator. A model of the high-temperature stage of a 1?-effect regenerator for liquid desiccants was designed, built and successfully tested. At nominal operating conditions (i.e., 2.35 gpm of 36% lithium chloride solution, 307,000 Btu/h firing rate), the boiler removed 153 lb/h of water from the desiccant at a gas-based efficiency of 52.9 % (which corresponds to a COP of 0.95 when a scavenging-air regenerator is added). The steam leaving the boiler, when condensed, had a solids concentration of less than 10 ppm. This low level of solids in the condensate places an upper bound of about 6 lb per year for desiccant loss from the regenerator. This low loss will not create

  5. An Autosampler and Field Sample Carrier for Maximizing Throughput Using an Open-Air, Surface Sampling Ion Source for MS

    EPA Science Inventory

    A recently developed, commercially available, open-air, surface sampling ion source for mass spectrometers provides individual analyses in several seconds. To realize its full throughput potential, an autosampler and field sample carrier were designed and built. The autosampler ...

  6. Active tracking of rejected dried blood samples in a large program in Nigeria

    PubMed Central

    Inalegwu, Auchi; Phillips, Sunny; Datir, Rawlings; Chime, Christopher; Ozumba, Petronilla; Peters, Samuel; Ogbanufe, Obinna; Mensah, Charles; Abimiku, Alash’Le; Dakum, Patrick; Ndembi, Nicaise

    2016-01-01

    AIM: To study the impact of rejection at different levels of health care by retrospectively reviewing records of dried blood spot samples received at the molecular laboratory for human immunodeficiency virus (HIV) early infant diagnosis (EID) between January 2008 and December 2012. METHODS: The specimen rejection rate, reasons for rejection and the impact of rejection at different levels of health care was examined. The extracted data were cleaned and checked for consistency and then de-duplicated using the unique patient and clinic identifiers. The cleaned data were ciphered and exported to SPSS version 19 (SPSS 2010 IBM Corp, New York, United States) for statistical analyses. RESULTS: Sample rejection rate of 2.4% (n = 786/32552) and repeat rate of 8.8% (n = 69/786) were established. The mean age of infants presenting for first HIV molecular test among accepted valid samples was 17.83 wk (95%CI: 17.65-18.01) vs 20.30 wk (95%CI: 16.53-24.06) for repeated samples. HIV infection rate was 9.8% vs 15.9% for accepted and repeated samples. Compared to tertiary healthcare clinics, secondary and primary clinics had two-fold and three-fold higher likelihood of sample rejection, respectively (P < 0.05). We observed a significant increase in sample rejection rate with increasing number of EID clinics (r = 0.893, P = 0.041). The major reasons for rejection were improper sample collection (26.3%), improper labeling (16.4%) and insufficient blood (14.8%). CONCLUSION: Programs should monitor pre-analytical variables and incorporate continuous quality improvement interventions to reduce errors associated with sample rejection and improve patient retention. PMID:27175352

  7. Protein expression profiling by antibody array analysis with use of dried blood spot samples on filter paper.

    PubMed

    Jiang, Weidong; Mao, Ying Qing; Huang, Ruochun; Duan, Chaohui; Xi, Yun; Yang, Kai; Huang, Ruo-Pan

    2014-01-31

    Dried blood spot samples (DBSS) on filter paper offer several advantages compared to conventional serum/plasma samples: they do not require any phlebotomy or separation of blood by centrifugation; they are less invasive; they allow sample stability and shipment at room temperature; and they pose a negligible risk of infection with blood-borne viruses, such as HIV, HBV and HCV, to those who handle them. Therefore dried blood spot samples (DBSS) on filter paper can be a quick, convenient and inexpensive means of obtaining blood samples for biomarker discovery, disease screening, diagnosis and treatment monitoring in non-hospitalized, public health settings. In this study, we investigated for the first time the potential application of dried blood spot samples (DBSS) in protein expression profiling using antibody array technology. First, optimal conditions for array assay performance using dried blood spot samples (DBSS) was established, including sample elution buffer, elution time, elution temperature and assay blocking buffer. Second, we analyzed dried blood spot samples (DBSS) using three distinct antibody array platforms, including sandwich-based antibody arrays, quantitative antibody arrays and biotin-label-based antibody arrays. In comparison with paired serum samples, detection of circulating proteins in dried blood spot samples (DBSS) correlated well for both low- and high-abundance proteins on all three antibody array platforms. In conclusion, our study strongly indicates the novel application of multiplex antibody array platforms to analyze dried blood spot samples (DBSS) on filter paper represents a viable, cost-effective method for protein profiling, biomarker discovery and disease screening in a large, population-based survey. PMID:24287424

  8. Comparative Evaluation of Physicochemical Properties of Pine Needle Powders Prepared by Different Drying Methods

    PubMed Central

    Chung, Ha-Sook; Lee, Jun Ho

    2015-01-01

    Systematic study of how different drying methods, namely hot-air drying, vacuum-drying, and freeze-drying, affect color, browning index, degree of rehydration, water solubility, and vitamin C content is critical for utilizing pine needle powders (PNP) as a novel ingredient in functional foods. Samples prepared by vacuum-drying showed a significantly higher L*-value, whereas higher a*- and b*-values were detected in the hot-air dried samples (P<0.05). The browning index was significantly higher in samples prepared by vacuum-drying compared to samples prepared by freeze-drying (P<0.05). Freeze-dried PNP exhibited a significantly higher degree of rehydration than hot-air dried samples (P<0.05). Water solubilities of freeze-dried and hot-air dried samples were significantly higher than that of vacuum-dried sample (P<0.05). Vitamin C was less destroyed during freeze-drying compared to hot-air or vacuum-drying (P<0.05). Freeze-dried samples displayed a clear porous structure and appeared to have a bigger space, whereas hot-air dried samples showed lower porosity than vacuum and freeze-dried samples. PMID:26176003

  9. Three years of greenhouse gas column-averaged dry air mole fractions retrieved from satellite Part 1: Carbon dioxide

    NASA Astrophysics Data System (ADS)

    Schneising, O.; Buchwitz, M.; Burrows, J. P.; Bovensmann, H.; Reuter, M.; Notholt, J.; Macatangay, R.; Warneke, T.

    2008-07-01

    Carbon dioxide (CO2) and methane (CH4) are the two most important anthropogenic greenhouse gases. SCIAMACHY on ENVISAT is the first satellite instrument whose measurements are sensitive to concentration changes of the two gases at all altitude levels down to the Earth's surface where the source/sink signals are largest. We have processed three years (2003 2005) of SCIAMACHY near-infrared nadir measurements to simultaneously retrieve vertical columns of CO2 (from the 1.58 μm absorption band), CH4 (1.66 μm) and oxygen (O2 A-band at 0.76 μm) using the scientific retrieval algorithm WFM-DOAS. We show that the latest version of WFM-DOAS, version 1.0, which is used for this study, has been significantly improved with respect to its accuracy compared to the previous versions while essentially maintaining its high processing speed (~1 min per orbit, corresponding to ~6000 single measurements, and per gas on a standard PC). The greenhouse gas columns are converted to dry air column-averaged mole fractions, denoted XCO2 (in ppm) and XCH4 (in ppb), by dividing the greenhouse gas columns by simultaneously retrieved dry air columns. For XCO2 dry air columns are obtained from the retrieved O2 columns. For XCH4 dry air columns are obtained from the retrieved CO2 columns because of better cancellation of light path related errors compared to using O2 columns retrieved from the spectrally distant O2 A-band. Here we focus on a discussion of the XCO2 data set. The XCH4 data set is discussed in a separate paper (Part 2). In order to assess the quality of the retrieved XCO2 we present comparisons with Fourier Transform Spectroscopy (FTS) XCO2 measurements at two northern hemispheric mid-latitude ground stations. To assess the quality globally, we present detailed comparisons with global XCO2 fields obtained from NOAA's CO2 assimilation system CarbonTracker. For the Northern Hemisphere we find good agreement with the reference data for the CO2 seasonal cycle and the CO2 annual

  10. Measurement and Comparison of Organic Compound Concentrations in Plasma, Whole Blood, and Dried Blood Spot Samples

    PubMed Central

    Batterman, Stuart A.; Chernyak, Sergey; Su, Feng-Chiao

    2016-01-01

    The preferred sampling medium for measuring human exposures of persistent organic compounds (POPs) is blood, and relevant sample types include whole blood, plasma, and dried blood spots (DBS). Because information regarding the performance and comparability of measurements across these sample types is limited, it is difficult to compare across studies. This study evaluates the performance of POP measurements in plasma, whole blood and DBS, and presents the distribution coefficients needed to convert concentrations among the three sample types. Blood samples were collected from adult volunteers, along with demographic and smoking information, and analyzed by GC/MS for organochlorine pesticides (OCPs), chlorinated hydrocarbons (CHCs), polychlorinated biphenyls (PCBs), and brominated diphenyl ethers (PBDEs). Regression models were used to evaluate the relationships between the sample types and possible effects of personal covariates. Distribution coefficients also were calculated using physically-based models. Across all compounds, concentrations in plasma were consistently the highest; concentrations in whole blood and DBS samples were comparable. Distribution coefficients for plasma to whole blood concentrations ranged from 1.74 to 2.26 for pesticides/CHCs, averaged 1.69 ± 0.06 for the PCBs, and averaged 1.65 ± 0.03 for the PBDEs. Regression models closely fit most chemicals (R2 > 0.80), and whole blood and DBS samples generally showed very good agreement. Distribution coefficients estimated using biologically-based models were near one and did not explain the observed distribution. Among the study population, median concentrations of several pesticides/CHCs and PBDEs exceeded levels reported in the 2007–2008 National Health and Nutrition Examination Survey, while levels of other OCPs and PBDEs were comparable or lower. Race and smoking status appeared to slightly affect plasma/blood concentration ratios for several POPs. The experimentally

  11. Significance of High-Speed Air Temperature Measurements in the Sampling Cell of a Closed-Path Gas Analyzer with a Short Tube

    NASA Astrophysics Data System (ADS)

    Kathilankal, James; Fratini, Gerardo; Burba, George

    2015-04-01

    Eddy covariance gas analyzers measure gas content in a known volume, thus essentially measuring gas density. The fundamental flux equation, however, is based on the dry mole fraction. The relationship between dry mole fraction and density is regulated by the ideal gas law describing the processes of temperature- and pressure-related expansions and contractions, and by the law of partial pressures, describing the process of dilution. As a result, this relationship depends on water vapor content, temperature and pressure of the air sample. If the instrument is able to output precise high-speed dry mole fraction, the flux processing is significantly simplified and WPL density terms accounting for the air density fluctuations are no longer required. This should also lead to the reduction in uncertainties associated with the density terms resulting from the eddy covariance measurements of sensible and latent heat fluxes used in these terms. In this framework, three main measurement approaches may be considered: Open-path approach Outputting correct high-speed dry mole fraction from the open-path instrument is difficult because of complexities with maintaining reliable fast temperature measurements integrated over the entire measuring path, and also because of extraordinary challenges with accurate measurements of fast pressure in the open air flow. Classical long-tube closed-path approach For instruments utilizing traditional long-tube closed-path design, with tube length 1000 or more times the tube diameter, the fast dry mole fraction can be used successfully when instantaneous fluctuations in the air temperature of the sampled air are effectively dampened to negligible levels, instantaneous pressure fluctuations are regulated or negligible, and water vapor is measured simultaneously with gas or the air sample is dried. Short-tube closed-path approach, the enclosed design For instruments with a short-tube enclosed design, most - but not all - of the temperature

  12. Air-Drying of Cells, the Novel Conditions for Stimulated Synthesis of Triacylglycerol in a Green Alga, Chlorella kessleri

    PubMed Central

    Minoda, Ayumi; Tsuzuki, Mikio; Sato, Norihiro

    2013-01-01

    Triacylglycerol is used for the production of commodities including food oils and biodiesel fuel. Microalgae can accumulate triacylglycerol under adverse environmental conditions such as nitrogen-starvation. This study explored the possibility of air-drying of green algal cells as a novel and simple protocol for enhancement of their triacylglycerol content. Chlorella kessleri cells were fixed on the surface of a glass fibre filter and then subjected to air-drying with light illumination. The dry cell weight, on a filter, increased by 2.7-fold in 96 h, the corresponding chlorophyll content ranging from 1.0 to 1.3-fold the initial one. Concomitantly, the triacylglycerol content remarkably increased to 70.3 mole% of fatty acids and 15.9% (w/w), relative to total fatty acids and dry cell weight, respectively, like in cells starved of nitrogen. Reduction of the stress of air-drying by placing the glass filter on a filter paper soaked in H2O lowered the fatty acid content of triacylglycerol to 26.4 mole% as to total fatty acids. Moreover, replacement of the H2O with culture medium further decreased the fatty acid content of triacylglycerol to 12.2 mole%. It thus seemed that severe dehydration is required for full induction of triacylglycerol synthesis, and that nutritional depletion as well as dehydration are crucial environmental factors. Meanwhile, air-drying of Chlamydomonas reinhardtii cells increased the triacylglycerol content to only 37.9 mole% of fatty acids and 4.8% (w/w), relative to total fatty acids and dry cell weight, respectively, and a marked decrease in the chlorophyll content, on a filter, of 33%. Air-drying thus has an impact on triacylglycerol synthesis in C. reinhardtii also, however, the effect is considerably limited, owing probably to instability of the photosynthetic machinery. This air-drying protocol could be useful for the development of a system for industrial production of triacylglycerol with appropriate selection of the algal species. PMID

  13. Comparison of the macroscopic properties of field-accelerated electrons in dry air and in pure oxygen

    NASA Astrophysics Data System (ADS)

    Fournier, G.; Bonnet, J.; Pigache, D.

    1980-06-01

    The numerical solution of the Boltzmann equation for an ionized gas yields the macroscopic properties of electrons accelerated by an electric field in dry air and in pure oxygen. For the purpose of ozone generation, the stronger the field, the better the efficiency of oxygen dissociation. In air, the oxygen dissociation is found to be much less easy than that at the same amount of pure oxygen.

  14. Direct Tandem Mass Spectrometric Profiling of Sulfatides in Dry Urinary Samples for Screening of Metachromatic Leukodystrophy

    PubMed Central

    Kuchař, Ladislav; Asfaw, Befekadu; Poupětová, Helena; Honzíková, Jitka; Tureček, František; Ledvinová, Jana

    2013-01-01

    Background Prediagnostic steps in suspected metachromatic leukodystrophy (MLD) rely onclinical chemical methods other than enzyme assays. We report a new diagnostic method which evaluates changes in the spectrum of molecular types of sulfatides (3-O-sulfogalactosyl ceramides) in MLD urine. Methods The procedure allows isolation of urinary sulfatides by solid-phase extraction on DEAE-cellulose membranes, transportation of a dry membrane followed by elution and tandem mass spectrometry (MS/MS) analysis in the clinical laboratory. Major sulfatide isoforms are normalized to the least variable component of the spectrum, which is the indigenous C18:0 isoform. This procedure does not require the use of specific internal standards and minimizes errors caused by sample preparation and measurement. Results Urinary sulfatides were analyzed in a set of 21 samples from patients affected by sulfatidosis. The combined abundance of the five most elevated isoforms, C22:0, C22:0-OH, C24:0, C24:1-OH, and C24:0-OH sulfatides, was found to give the greatest distinction between MLD-affected patients and a control group. Conclusions The method avoids transportation of liquid urine samples and generates stable membrane-bound sulfatide samples that can be stored at ambient temperature. MS/MS sulfatide profiling targeted on the most MLD-representative isoforms is simple with robust results and is suitable for screening. PMID:23838369

  15. Collection and analysis of NASA clean room air samples

    NASA Technical Reports Server (NTRS)

    Sheldon, L. S.; Keever, J.

    1985-01-01

    The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

  16. Air sampling filtration media: Collection efficiency for respirable size-selective sampling

    PubMed Central

    Soo, Jhy-Charm; Monaghan, Keenan; Lee, Taekhee; Kashon, Mike; Harper, Martin

    2016-01-01

    The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 μm pore sizes), polycarbonate (0.4, 0.8, 2, and 5 μm pore sizes), polytetrafluoroethylene (PTFE; 0.45, 1, 2, and 5 μm pore sizes), polyvinyl chloride (PVC; 0.8 and 5 μm pore sizes), and silver membrane (0.45, 0.8, 1.2, and 5 μm pore sizes) filters were exposed to polydisperse sodium chloride (NaCl) particles in the size range of 10–400 nm. Test aerosols were nebulized and introduced into a calm air chamber through a diffusion dryer and aerosol neutralizer. The testing filters (37 mm diameter) were mounted in a conductive polypropylene filter-holder (cassette) within a metal testing tube. The experiments were conducted at flow rates between 1.7 and 11.2 l min−1. The particle size distributions of NaCl challenge aerosol were measured upstream and downstream of the test filters by a scanning mobility particle sizer (SMPS). Three different filters of each type with at least three repetitions for each pore size were tested. In general, the collection efficiency varied with airflow, pore size, and sampling duration. In addition, both collection efficiency and pressure drop increased with decreased pore size and increased sampling flow rate, but they differed among filter types and manufacturer. The present study confirmed that the MCE, PTFE, and PVC filters have a relatively high collection efficiency for challenge particles much smaller than their nominal pore size and are considerably more efficient than polycarbonate and silver membrane filters, especially at larger nominal pore sizes. PMID:26834310

  17. Decorin content and near infrared spectroscopy analysis of dried collagenous biomaterial samples.

    PubMed

    Aldema-Ramos, Mila L; Castell, Joan Carles; Muir, Zerlina E; Adzet, Jose Maria; Sabe, Rosa; Schreyer, Suzanne

    2012-01-01

    The efficient removal of proteoglycans, such as decorin, from the hide when processing it to leather by traditional means is generally acceptable and beneficial for leather quality, especially for softness and flexibility. A patented waterless or acetone dehydration method that can generate a product similar to leather called Dried Collagenous Biomaterial (known as BCD) was developed but has no effect on decorin removal efficiency. The Alcian Blue colorimetric technique was used to assay the sulfated glycosaminoglycan (sGAG) portion of decorin. The corresponding residual decorin content was correlated to the mechanical properties of the BCD samples and was comparable to the control leather made traditionally. The waterless dehydration and instantaneous chrome tanning process is a good eco-friendly alternative to transforming hides to leather because no additional effects were observed after examination using NIR spectroscopy and additional chemometric analysis. PMID:24970152

  18. Investigation on the Importance of Fast Air Temperature Measurements in the Sampling Cell of Short-Tube Closed-Path Gas Analyzer for Eddy-Covariance Fluxes

    NASA Astrophysics Data System (ADS)

    Kathilankal, J. C.; Fratini, G.; Burba, G. G.

    2014-12-01

    High-speed, precise gas analyzers used in eddy covariance flux research measure gas content in a known volume, thus essentially measuring gas density. The classical eddy flux equation, however, is based on the dry mole fraction. The relation between dry mole fraction and density is regulated by the ideal gas law and law of partial pressures, and depends on water vapor content, temperature and pressure of air. If the instrument can output precise fast dry mole fraction, the flux processing is significantly simplified and WPL terms accounting for air density fluctuations are no longer required. This will also lead to the reduction in uncertainties associated with the WPL terms. For instruments adopting an open-path design, this method is difficult to use because of complexities with maintaining reliable fast temperature measurements integrated over the entire measuring path, and also because of extraordinary challenges with accurate measurements of fast pressure in the open air flow. For instruments utilizing a traditional long-tube closed-path design, with tube length 1000 or more times the tube diameter, this method can be used when instantaneous fluctuations in the air temperature of the sampled air are effectively dampened, instantaneous pressure fluctuations are regulated or negligible, and water vapor is measured simultaneously with gas, or the sample is dried. For instruments with a short-tube enclosed design, most - but not all - of the temperature fluctuations are attenuated, so calculating unbiased fluxes using fast dry mole fraction output requires high-speed, precise temperature measurements of the air stream inside the cell. In this presentation, authors look at short-term and long-term data sets to assess the importance of high-speed, precise air temperature measurements in the sampling cell of short-tube enclosed gas analyzers. The CO2 and H2O half hourly flux calculations, as well as long-term carbon and water budgets, are examined.

  19. Comparative analysis of dry ashing and wet digestion methods for the determination of trace and heavy metals in food samples.

    PubMed

    Akinyele, I O; Shokunbi, O S

    2015-04-15

    This study compared the dry ashing and wet digestion methods of processing food samples for elemental analysis. The concentrations of trace elements (manganese, iron, copper and zinc) and heavy metals (chromium, cadmium, lead and nickel) were determined in varieties of samples classified as fruits, leafy and fruity vegetables, tubers, legumes and cereals, obtained from Abeokuta, South-West, Nigeria. The metal concentrations were determined using atomic absorption spectrophotometer according to standard methods. The accuracy of the procedures was confirmed by spiking some samples and evaluating their recoveries. The metal levels evaluated were relatively higher in the dry-ashed samples than the wet-digested samples. However, the results showed non-significant differences in most data obtained after processing with the two methods. The dry ashing method is recommended for digestion of food items in these categories because: it involves lesser amount of chemical reagents and related hazards; it requires simple equipment and achieved better recovery. PMID:25466076

  20. Sulfatide Analysis by Mass Spectrometry for Screening of Metachromatic Leukodystrophy in Dried Blood and Urine Samples

    PubMed Central

    Spacil, Zdenek; Kumar, Arun Babu; Liao, Hsuan-Chieh; Auray-Blais, Christiane; Stark, Samantha; Suhr, Teryn R.; Scott, C. Ronald; Turecek, Frantisek; Gelb, Michael H.

    2016-01-01

    BACKGROUND Metachromatic leukodystrophy (MLD) is an autosomal recessive disorder caused by deficiency in arylsulfatase A activity, leading to accumulation of sulfatide substrates. Diagnostic and monitoring procedures include demonstration of reduced arylsulfatase A activity in peripheral blood leukocytes or detection of sulfatides in urine. However, the development of a screening test is challenging because of instability of the enzyme in dried blood spots (DBS), the widespread occurrence of pseudodeficiency alleles, and the lack of available urine samples from newborn screening programs. METHODS We measured individual sulfatide profiles in DBS and dried urine spots (DUS) from MLD patients with LC-MS/MS to identify markers with the discriminatory power to differentiate affected individuals from controls. We also developed a method for converting all sulfatide molecular species into a single species, allowing quantification in positive-ion mode upon derivatization. RESULTS In DBS from MLD patients, we found up to 23.2-fold and 5.1-fold differences in total sulfatide concentrations for early- and late-onset MLD, respectively, compared with controls and pseudodeficiencies. Corresponding DUS revealed up to 164-fold and 78-fold differences for early- and late-onset MLD patient samples compared with controls. The use of sulfatides converted to a single species simplified the analysis and increased detection sensitivity in positive-ion mode, providing a second option for sulfatide analysis. CONCLUSIONS This study of sulfatides in DBS and DUS suggests the feasibility of the mass spectrometry method for newborn screening of MLD and sets the stage for a larger-scale newborn screening pilot study. PMID:26585924

  1. Breakthrough of 1,3-dichloropropene and chloropicrin from 600 mg XAD-4 air sampling tubes

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Accurately measuring air concentrations of agricultural fumigants is important for the regulation of air quality. Understanding the conditions under which sorbent tubes can effectively retain such fumigants during sampling is critical in mitigating chemical breakthrough from the tubes and facilitati...

  2. Dust particle charge screening in the dry-air plasma produced by an external ionization source

    SciTech Connect

    Derbenev, I. N.; Filippov, A. V.

    2015-08-15

    The ionic composition of the plasma produced by an external ionization source in dry air at atmospheric pressure and room temperature and the screening of the electric field of a dust particle in such a plasma have been investigated. The point sink model based on the diffusion-drift approximation has been used to solve the screening problem. We have established that the main species of ions in the plasma under consideration are O{sub 4}{sup +}, O{sub 2}{sup -}, and O{sub 4}{sup -} and that the dust particle potential distribution is described by a superposition of four exponentials with four different constants. We show that the first constant coincides with the inverse Debye length, the second is described by the inverse ambipolar diffusion length of the positive and negative plasma components in the characteristic time of their recombination, the third is determined by the conversion of negative ions, and the fourth is determined by the attachment and recombination of electrons and diatomic ions.

  3. Remediation of muddy tidal flat sediments using hot air-dried crushed oyster shells.

    PubMed

    Yamamoto, Tamiji; Kondo, Shunsuke; Kim, Kyung-Hoi; Asaoka, Satoshi; Yamamoto, Hironori; Tokuoka, Makoto; Hibino, Tadashi

    2012-11-01

    In order to prove that hot air-dried crushed oyster shells (HACOS) are effective in reducing hydrogen sulfide in muddy tidal flat sediments and increasing the biomass, field experiments were carried out. The concentration of hydrogen sulfide in the interstitial water, which was 16 mg SL(-1) before the application of HACOS, decreased sharply and maintained almost zero in the experimental sites (HACOS application sites) for one year, whereas it was remained at ca. 5 mg SL(-1) in the control sites. The number of macrobenthos individuals increased to 2-4.5 times higher than that in the control site. Using a simple numerical model, the effective periods for suppression of hydrogen sulfide were estimated to be 3.2-7.6 and 6.4-15.2 years for the experimental sites with 4 and 8 tons per 10 × 10 × 0.2m area, respectively. From these results, it is concluded that HACOS is an effective material to remediate muddy tidal flats. PMID:23017947

  4. Influence of operating conditions on the air gasification of dry refinery sludge in updraft gasifier

    NASA Astrophysics Data System (ADS)

    Ahmed, R.; Sinnathambi, C. M.

    2013-06-01

    In the present work, details of the equilibrium modeling of dry refinery sludge (DRS) are presented using ASPEN PLUS Simulator in updraft gasifier. Due to lack of available information in the open journal on refinery sludge gasification using updraft gasifier, an evaluate for its optimum conditions on gasification is presented in this paper. For this purpose a Taguchi Orthogonal array design, statistical software is applied to find optimum conditions for DRS gasification. The goal is to identify the most significant process variable in DRS gasification conditions. The process variables include; oxidation zone temperature, equivalent ratio, operating pressure will be simulated and examined. Attention was focused on the effect of optimum operating conditions on the gas composition of H2 and CO (desirable) and CO2 (undesirable) in terms of mass fraction. From our results and finding it can be concluded that the syngas (H2 & CO) yield in term of mass fraction favors high oxidation zone temperature and at atmospheric pressure while CO2 acid gas favor at a high level of equivalent ratio as well as air flow rate favoring towards complete combustion.

  5. Nature of organo-mineral particles across density fractions in a volcanic-ash soil: air-drying and sonication effect

    NASA Astrophysics Data System (ADS)

    Wagai, R.; Kajiura, M.; Shirato, Y.; Uchida, M.

    2011-12-01

    Interactions of plant- and microbially-derived organic matter with mineral phases exert significant controls on the stabilization of organic matter (OM) as well as other biogeochemical processes in soil. Density fractionation techniques have been successful in distinguishing soil organo-mineral particles of different degrees of microbial alteration, turnover rate of C, mineral associations. A major methodological difference among the density fractionation studies is the choice of sample pre-treatment. Presence or absence of sonication to disrupt and disperse soil particles and aggregates is a particularly important choice which could significantly alter the nature and distribution of organo-mineral particle and thus the resultant elemental concentration in each density fraction. Soil moisture condition (air-dry vs. field-moist) may also have strong impact especially for soils rich in Fe oxides/hydroxides and/or poorly-crystalline minerals that are prone for (possibly irreversible) aggregation. We thus tested these two effects on the concentration and distribution of C, N, and extractable phases of Fe and Al (by pyrophosphate and acid oxalate) across six density fractions (from <1.6 to >2.5 g/cm^3) using a surface-horizon of volcanic-ash soil which contained large amounts of poorly-crystalline minerals and organo-metal complexes. Compared to field-moist sample, air-drying had little effects on the elemental concentration or distribution across the fractions. In contrast, sonication on air-dried sample at each density cutoff during fractionation process caused significant changes. In addition to well-known increase in low-density material due to the liberation of plant detritus upon aggregate disruption, we found clear increase in C, N, and metals in 2.0-2.3 g/cm^3 fraction, which was largely compensated by the reduction in 1.8-2.0 g/cm^3 and, to a less extent, 2.3-2.5 g/cm^3 particles. Overall, sonication led to the redistribution of C and N by 15-20% and that of

  6. Estimating Sampling Biases and Measurement Uncertainties of AIRS-AMSU-A Temperature and Water Vapor Observations Using MERRA Reanalysis

    NASA Technical Reports Server (NTRS)

    Hearty, Thomas J.; Savtchenko, Andrey K.; Tian, Baijun; Fetzer, Eric; Yung, Yuk L.; Theobald, Michael; Vollmer, Bruce; Fishbein, Evan; Won, Young-In

    2014-01-01

    We use MERRA (Modern Era Retrospective-Analysis for Research Applications) temperature and water vapor data to estimate the sampling biases of climatologies derived from the AIRS/AMSU-A (Atmospheric Infrared Sounder/Advanced Microwave Sounding Unit-A) suite of instruments. We separate the total sampling bias into temporal and instrumental components. The temporal component is caused by the AIRS/AMSU-A orbit and swath that are not able to sample all of time and space. The instrumental component is caused by scenes that prevent successful retrievals. The temporal sampling biases are generally smaller than the instrumental sampling biases except in regions with large diurnal variations, such as the boundary layer, where the temporal sampling biases of temperature can be +/- 2 K and water vapor can be 10% wet. The instrumental sampling biases are the main contributor to the total sampling biases and are mainly caused by clouds. They are up to 2 K cold and greater than 30% dry over mid-latitude storm tracks and tropical deep convective cloudy regions and up to 20% wet over stratus regions. However, other factors such as surface emissivity and temperature can also influence the instrumental sampling bias over deserts where the biases can be up to 1 K cold and 10% wet. Some instrumental sampling biases can vary seasonally and/or diurnally. We also estimate the combined measurement uncertainties of temperature and water vapor from AIRS/AMSU-A and MERRA by comparing similarly sampled climatologies from both data sets. The measurement differences are often larger than the sampling biases and have longitudinal variations.

  7. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  8. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  9. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Approved sampling devices; operation; air... DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  10. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  11. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  12. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  13. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  14. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Approved sampling devices; operation; air... DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  15. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  16. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  17. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  18. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  19. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Approved sampling devices; operation; air... DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  20. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  1. Efficient IDUA Gene Mutation Detection with Combined Use of dHPLC and Dried Blood Samples

    PubMed Central

    Duarte, Ana Joana; Vieira, Luis

    2013-01-01

    Objectives. Development of a simple mutation directed method in order to allow lowering the cost of mutation testing using an easily obtainable biological material. Assessment of the feasibility of such method was tested using a GC-rich amplicon. Design and Methods. A method of denaturing high-performance liquid chromatography (dHPLC) was improved and implemented as a technique for the detection of variants in exon 9 of the IDUA gene. The optimized method was tested in 500 genomic DNA samples obtained from dried blood spots (DBS). Results. With this dHPLC approach it was possible to detect different variants, including the common p.Trp402Ter mutation in the IDUA gene. The high GC content did not interfere with the resolution and reliability of this technique, and discrimination of G-C transversions was also achieved. Conclusion. This PCR-based dHPLC method is proved to be a rapid, a sensitive, and an excellent option for screening numerous samples obtained from DBS. Furthermore, it resulted in the consistent detection of clearly distinguishable profiles of the common p.Trp402Ter IDUA mutation with an advantageous balance of cost and technical requirements. PMID:27335677

  2. Review of Various Air Sampling Methods for Solvent Vapors.

    ERIC Educational Resources Information Center

    Maykoski, R. T.

    Vapors of trichloroethylene, toluene, methyl ethyl ketone, and butyl cellosolve in air were collected using Scotchpac and Tedlar bags, glass prescription bottles, and charcoal adsorption tubes. Efficiencies of collection are reported. (Author/RH)

  3. Studies on pulsed Nd:YAG laser cutting of thick stainless steel in dry air and underwater environment for dismantling applications

    NASA Astrophysics Data System (ADS)

    Choubey, Ambar; Jain, R. K.; Ali, Sabir; Singh, Ravindra; Vishwakarma, S. C.; Agrawal, D. K.; Arya, R.; Kaul, R.; Upadhyaya, B. N.; Oak, S. M.

    2015-08-01

    Dismantling of old equipments and structures is an important application in nuclear facilities and shipping industry. This paper presents a study on process optimization during pulsed Nd:YAG laser cutting of thick stainless steel (AISI SS304) sheets having a thickness in the range of 4-20 mm in dry air and underwater environment. Laser cutting experiments have been performed using a 500 W average power long pulse Nd:YAG laser system with fiber optic beam delivery. A water shielded laser cutting nozzle with coaxial gas jet was specifically developed to form a local dry cavity around the laser beam during the cutting experiments in underwater condition. It was found that for a given pulse energy, a higher cutting speed is possible with optimal value of pulse duration, spot overlapping, and assist gas pressure. Cutting speed of 20 mm thick SS sample was enhanced to about three times by means of increase in pulse duration from 14 ms to 20 ms and reduction in the required spot overlapping from a value of 80% to 40% using oxygen as the assist gas. A comparison of the cutting speed and heat affected zone in dry air and underwater environment has been performed. These results will be highly useful in laser based dismantling of old steel structures in radioactive and underwater environment to save time and minimize radiation dose consumption as compared to conventional dismantling methods.

  4. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    NASA Astrophysics Data System (ADS)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  5. Monitoring ambient air pollutants and apply Woods' model in the prediction seasonal dry deposition at Chang-Hua (urban) and Kao-Mei (wetland) county, Taiwan.

    PubMed

    Fang, Guor-Cheng; Chang, Chia-Ying

    2014-09-01

    The main purpose for this study was to monitor ambient air particles and metallic elements (Mn, Fe, Zn, Cr, Cu and Pb) in total suspended particulate (TSP) concentration and dry deposition. In addition, the calculated/measured dry deposition flux ratios of ambient air particles and metallic elements (Mn, Fe, Zn, Cr, Cu and Pb) were evaluated using Woods' model at urban and wetland areas for the 2009-2010 period. The results indicated that the mean highest concentrations of metallic elements Mn, Fe, Zn, Cr, Cu and Pb in TSP were found in Chang-Hua (urban) sampling site. And as for the two characteristic sampling sites, the Woods' model exhibits better dry deposition of particulates of 18 µm particle size than the rest of the other particle sizes at any sampling site in this study. The average calculated/measured flux ratios for two seasons (summer and fall) by using Woods model at 2.5, 10 and 18 µm particles sizes were also studied. The results indicated that the average calculated/measured flux ratios orders for two seasons of various particles sizes were all displayed as Fe > Mn > Zn > Cu > Cr > Pb > particle. And these calculated/measured flux ratios orders were Fe > Mn > Cu > Zn > Cr > Pb > particle and were Fe > Mn > Zn > Cu > Cr > particle > Pb, during spring and winter seasons, respectively. Finally, in the spring and summer seasons of Gao-Mei (wetland) sampling site, the average calculated/measured flux ratios using Woods' model was found to be 2.5, 10 and 18 µm, showing the order of the calculated/measured flux ratios to be Fe > Cu > Zn > Mn > Cr > Pb > particle. And the calculated/measured flux ratio orders were Fe > Zn > Mn > Cu > Cr > particle > Pb and were Fe > Cu > Zn > Mn > Cr > particle > Pb for fall and winter season, respectively. PMID:23070636

  6. Enhanced Stability of Blood Matrices Using a Dried Sample Spot Assay to Measure Human Butyrylcholinesterase Activity and Nerve Agent Adducts

    PubMed Central

    Perez, Jonas W.; Pantazides, Brooke G.; Watson, Caroline M.; Thomas, Jerry D.; Blake, Thomas A.; Johnson, Rudolph C.

    2015-01-01

    Dried matrix spots are safer to handle and easier to store than wet blood products, but factors such as intra-spot variability and unknown sample volumes have limited their appeal as a sampling format for quantitative analyses. In this work, we introduce a dried spot activity assay for quantifying butyrylcholinesterase (BChE) specific activity which is BChE activity normalized to the total protein content in a sample spot. The method was demonstrated with blood, serum, and plasma spotted on specimen collection devices (cards) which were extracted to measure total protein and BChE activity using a modified Ellman assay. Activity recovered from dried spots was ∼80% of the initial spotted activity for blood and >90% for plasma and serum. Measuring total protein in the sample and calculating specific activity substantially improved quantification and reduced intra-spot variability. Analyte stability of nerve agent adducts was also evaluated, and the results obtained via BChE-specific activity measurements were confirmed by quantification of BChE adducts using a previously established LC-MS/MS method. The spotted samples were up to 10-times more resistant to degradation compared to unspotted control samples when measuring BChE inhibition by the nerve agents sarin and VX. Using this method, both BChE activity and adducts can be accurately measured from a dried sample spot. This use of a dried sample spot with normalization to total protein is robust, demonstrates decreased intra-spot variability without the need to control for initial sample volume, and enhances analyte stability. PMID:25955132

  7. Day and night variation in chemical composition and toxicological responses of size segregated urban air PM samples in a high air pollution situation

    NASA Astrophysics Data System (ADS)

    Jalava, P. I.; Wang, Q.; Kuuspalo, K.; Ruusunen, J.; Hao, L.; Fang, D.; Väisänen, O.; Ruuskanen, A.; Sippula, O.; Happo, M. S.; Uski, O.; Kasurinen, S.; Torvela, T.; Koponen, H.; Lehtinen, K. E. J.; Komppula, M.; Gu, C.; Jokiniemi, J.; Hirvonen, M.-R.

    2015-11-01

    Urban air particulate pollution is a known cause for adverse human health effects worldwide. China has encountered air quality problems in recent years due to rapid industrialization. Toxicological effects induced by particulate air pollution vary with particle sizes and season. However, it is not known how distinctively different photochemical activity and different emission sources during the day and the night affect the chemical composition of the PM size ranges and subsequently how it is reflected to the toxicological properties of the PM exposures. The particulate matter (PM) samples were collected in four different size ranges (PM10-2.5; PM2.5-1; PM1-0.2 and PM0.2) with a high volume cascade impactor. The PM samples were extracted with methanol, dried and thereafter used in the chemical and toxicological analyses. RAW264.7 macrophages were exposed to the particulate samples in four different doses for 24 h. Cytotoxicity, inflammatory parameters, cell cycle and genotoxicity were measured after exposure of the cells to particulate samples. Particles were characterized for their chemical composition, including ions, element and PAH compounds, and transmission electron microscopy (TEM) was used to take images of the PM samples. Chemical composition and the induced toxicological responses of the size segregated PM samples showed considerable size dependent differences as well as day to night variation. The PM10-2.5 and the PM0.2 samples had the highest inflammatory potency among the size ranges. Instead, almost all the PM samples were equally cytotoxic and only minor differences were seen in genotoxicity and cell cycle effects. Overall, the PM0.2 samples had the highest toxic potential among the different size ranges in many parameters. PAH compounds in the samples and were generally more abundant during the night than the day, indicating possible photo-oxidation of the PAH compounds due to solar radiation. This was reflected to different toxicity in the PM

  8. Field evaluation of sampling and analysis for organic pollutants in indoor air. Project summary

    SciTech Connect

    Chuang, J.C.; Mack, G.A.; Stockrahm, J.W.; Hannan, S.W.; Bridges, C.

    1988-09-01

    The objectives of the study were to determine the feasibility of the use of newly developed indoor air samplers in residential indoor air sampling and to evaluate methodology for characterization of the concentrations of polynuclear aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in residential air.

  9. In situ characterization of Zircaloy-4 oxidation at 500 °C in dry air

    NASA Astrophysics Data System (ADS)

    Vermoyal, J. J.; Dessemond, L.; Hammou, A.; Frichet, A.

    2001-10-01

    The in situ oxidation of Zircaloy-4 at 500 °C in dry air was investigated by thermogravimetric analysis (TGA) and electrochemical impedance spectroscopy (EIS). The coating of the alloy by a platinum film as electrode material was observed as not to modify the oxidation kinetic properties. After an initial cubic rate law, a transition to a quasi-linear curve occurs. The independence of the oxidation behavior to the Pt coupling is compatible with oxygen diffusion as the rate-determining step. During the pre-transition step, the rest potential of the cell Pt/oxide/Zy-4, the color of the oxide and the modulus of the single EIS signature indicate the high non-stoichiometry of the oxide. The kinetic transition was proposed to be correlated to the degradation of the film into a partially porous layer. This alteration of the oxide is associated to the appearance of a 1.2 V constant rest potential and the modification of the impedance diagrams in two high modulus contributions. The Cole-Cole representation has been used to demonstrate that the time variation of impedance spectra is related to the oxide growth. An equivalent circuit including two RC loops in series, whose capacitances are frequency dispersed, was proposed to be related to the film structure. Fitted data show that the thickness of the assumed protective layer of the film, close to the metal-oxide interface, is time independent in agreement with a constant oxidation rate. Finally, electrical properties of this inner layer were found to be quite different in pre- and post-transition stage.

  10. Dried Blood Spot Proteomics: Surface Extraction of Endogenous Proteins Coupled with Automated Sample Preparation and Mass Spectrometry Analysis

    NASA Astrophysics Data System (ADS)

    Martin, Nicholas J.; Bunch, Josephine; Cooper, Helen J.

    2013-08-01

    Dried blood spots offer many advantages as a sample format including ease and safety of transport and handling. To date, the majority of mass spectrometry analyses of dried blood spots have focused on small molecules or hemoglobin. However, dried blood spots are a potentially rich source of protein biomarkers, an area that has been overlooked. To address this issue, we have applied an untargeted bottom-up proteomics approach to the analysis of dried blood spots. We present an automated and integrated method for extraction of endogenous proteins from the surface of dried blood spots and sample preparation via trypsin digestion by use of the Advion Biosciences Triversa Nanomate robotic platform. Liquid chromatography tandem mass spectrometry of the resulting digests enabled identification of 120 proteins from a single dried blood spot. The proteins identified cross a concentration range of four orders of magnitude. The method is evaluated and the results discussed in terms of the proteins identified and their potential use as biomarkers in screening programs.

  11. Occurrence of ochratoxin a contamination and detection of ochratoxigenic Aspergillus species in retail samples of dried fruits and nuts.

    PubMed

    Palumbo, Jeffrey D; O'Keeffe, Teresa L; Ho, Yvonne S; Santillan, Carlo J

    2015-04-01

    Ochratoxin A (OTA) is a mycotoxin produced by several species of Aspergillus and Penicillium and is a potential contaminant of a wide variety of food products. To determine the incidence of OTA contamination in dried fruits and tree nuts, retail packaged and bulk raisins, dates, figs, prunes, almonds, pistachios, and walnuts were collected from small and large supermarkets in seven areas of the United States between 2012 and 2014. Of the 665 samples analyzed, OTA was detected in 48 raisin samples, 4 fig samples, 4 pistachio samples, and 1 date sample. OTA contamination levels ranged from 0.28 to 15.34 ng/g in dried fruits and 1.87 to 890 ng/g in pistachios; two raisin samples and one pistachio sample exceeded the European Union regulatory limit of 10 ng/g. PCR detection of potential OTA-producing Aspergillus species revealed the presence of A. niger, A. welwitschiae, and A. carbonarius in 20, 7, and 7 of the 57 OTA-contaminated samples, respectively. However, OTA-producing A. carbonarius was isolated from only one raisin sample, and no other OTA-producing Aspergillus species were found. These results suggest that raisins are more frequently contaminated with low levels of OTA than are other dried fruits and nuts and that Aspergillus species are the likely source of that contamination. PMID:25836414

  12. Rapid on-site air sampling with a needle extraction device for evaluating the indoor air environment in school facilities.

    PubMed

    Inoue, Mitsuru; Mizuguchi, Ayako; Ueta, Ikuo; Takahashi, Kazuya; Saito, Yoshihiro

    2013-01-01

    A rapid on-site air sampling technique was developed with a miniaturized needle-type sample preparation device for a systematic evaluation of the indoor air environments in school facilities. With the in-needle extraction device packed with a polymer particle of divinylbenzene and activated carbon particles, various types of volatile organic compounds (VOCs) were successfully extracted. For evaluating the indoor air qualities in school facilities, air samples in renovated rooms using organic solvent as a thinner of the paint were analyzed along with measurements of several VOCs in indoor air samples taken in newly built primary schools mainly using low-VOCs materials. After periodical renovation/maintenance, the time-variation profile of typical VOCs found in the school facilities has also been monitored. From the results, it could be observed that the VOCs in most of the rooms in these primary schools were at a quite low level; however, a relatively higher concentration of VOCs was found in some specially designed rooms, such as music rooms. In addition, some non-regulated compounds, including benzyl alcohol and branched alkanes, were detected in these primary schools. The results showed a good applicability of the needle device to indoor air analysis in schools, suggesting a wide range of future employment of the needle device, especially for indoor air analysis in other types of facilities and rooms including hospitals and hotels. PMID:23665624

  13. Drying characteristics of garlic ( Allium sativum L) slices in a convective hot air dryer

    NASA Astrophysics Data System (ADS)

    Demiray, Engin; Tulek, Yahya

    2014-06-01

    The effects of drying temperatures on the drying kinetics of garlic slices were investigated using a cabinet-type dryer. The experimental drying data were fitted best to the Page and Modified Page models apart from other theoretical models to predict the drying kinetics. The effective moisture diffusivities varied from 4.214 × 10-10 to 2.221 × 10-10 m2 s-1 over the temperature range studied, and activation energy was 30.582 kJ mol-1.

  14. Estimation of tiger densities in the tropical dry forests of Panna, Central India, using photographic capture-recapture sampling

    USGS Publications Warehouse

    Karanth, K.U.; Chundawat, R.S.; Nichols, J.D.; Kumar, N.S.

    2004-01-01

    Tropical dry-deciduous forests comprise more than 45% of the tiger (Panthera tigris) habitat in India. However, in the absence of rigorously derived estimates of ecological densities of tigers in dry forests, critical baseline data for managing tiger populations are lacking. In this study tiger densities were estimated using photographic capture?recapture sampling in the dry forests of Panna Tiger Reserve in Central India. Over a 45-day survey period, 60 camera trap sites were sampled in a well-protected part of the 542-km2 reserve during 2002. A total sampling effort of 914 camera-trap-days yielded photo-captures of 11 individual tigers over 15 sampling occasions that effectively covered a 418-km2 area. The closed capture?recapture model Mh, which incorporates individual heterogeneity in capture probabilities, fitted these photographic capture history data well. The estimated capture probability/sample, 0.04, resulted in an estimated tiger population size and standard error of 29 (9.65), and a density of 6.94 (3.23) tigers/100 km2. The estimated tiger density matched predictions based on prey abundance. Our results suggest that, if managed appropriately, the available dry forest habitat in India has the potential to support a population size of about 9000 wild tigers.

  15. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge

    PubMed Central

    Catarino, Rosa; Vassilakos, Pierre; Bilancioni, Aline; Vanden Eynde, Mathieu; Meyer-Hamme, Ulrike; Menoud, Pierre-Alain; Guerry, Frédéric; Petignat, Patrick

    2015-01-01

    Background Human papillomavirus (HPV) self-sampling (self-HPV) is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab. Methods A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed first: self-HPV using dry swabs (s-DRY) or vaginal specimen collection using a cytobrush applied to an FTA cartridge (s-FTA). After self-HPV, a physician collected a cervical sample using liquid-based medium (Dr-WET). HPV types were identified by real-time PCR. Agreement between collection methods was measured using the kappa statistic. Results HPV prevalence for high-risk types was 62.3% (95%CI: 53.7–70.2) detected by s-DRY, 56.2% (95%CI: 47.6–64.4) by Dr-WET, and 54.6% (95%CI: 46.1–62.9) by s-FTA. There was overall agreement of 70.8% between s-FTA and s-DRY samples (kappa = 0.34), and of 82.3% between self-HPV and Dr-WET samples (kappa = 0.56). Detection sensitivities for low-grade squamous intraepithelial lesion or worse (LSIL+) were: 64.0% (95%CI: 44.5–79.8) for s-FTA, 84.6% (95%CI: 66.5–93.9) for s-DRY, and 76.9% (95%CI: 58.0–89.0) for Dr-WET. The preferred self-collection method among patients was s-DRY (40.8% vs. 15.4%). Regarding costs, FTA card was five times more expensive than the swab (~5 US dollars (USD)/per card vs. ~1 USD/per swab). Conclusion Self-HPV using dry swabs is sensitive for detecting LSIL+ and less expensive than s-FTA. Trial Registration International Standard Randomized Controlled Trial Number (ISRCTN): 43310942 PMID:26630353

  16. The ice nucleation temperature determines the primary drying rate of lyophilization for samples frozen on a temperature-controlled shelf.

    PubMed

    Searles, J A; Carpenter, J F; Randolph, T W

    2001-07-01

    The objective of this study was to determine the influence of ice nucleation temperature on the primary drying rate during lyophilization for samples in vials that were frozen on a lyophilizer shelf. Aqueous solutions of 10% (w/v) hydroxyethyl starch were frozen in vials with externally mounted thermocouples and then partially lyophilized to determine the primary drying rate. Low- and high-particulate-containing samples, ice-nucleating additives silver iodide and Pseudomonas syringae, and other methods were used to obtain a wide range of nucleation temperatures. In cases where the supercooling exceeded 5 degrees C, freezing took place in the following three steps: (1) primary nucleation, (2) secondary nucleation encompassing the entire liquid volume, and (3) final solidification. The primary drying rate was dependent on the ice nucleation temperature, which is stochastic in nature but is affected by particulate content and the presence of ice nucleators. Sample cooling rates of 0.05 to 1 degrees C/min had no effect on nucleation temperatures and drying rate. We found that the ice nucleation temperature is the primary determinant of the primary drying rate. However, the nucleation temperature is not under direct control, and its stochastic nature and sensitivity to difficult-to-control parameters result in drying rate heterogeneity. Nucleation temperature heterogeneity may also result in variation in other morphology-related parameters such as surface area and secondary drying rate. Overall, these results document that factors such as particulate content and vial condition, which influence ice nucleation temperature, must be carefully controlled to avoid, for example, lot-to-lot variability during cGMP production. In addition, if these factors are not controlled and/or are inadvertently changed during process development and scaleup, a lyophilization cycle that was successful on the research scale may fail during large-scale production. PMID:11458335

  17. Toxicological Assessment of ISS Air Quality: Contingency Sampling - February 2013

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie

    2013-01-01

    Two grab sample containers (GSCs) were collected by crew members onboard ISS in response to a vinegar-like odor in the US Lab. On February 5, the first sample was collected approximately 1 hour after the odor was noted by the crew in the forward portion of the Lab. The second sample was collected on February 22 when a similar odor was noted and localized to the end ports of the microgravity science glovebox (MSG). The crewmember removed a glove from the MSG and collected the GSC inside the glovebox volume. Both samples were returned on SpaceX-2 for ground analysis.

  18. Leaching heavy metals from the surface soil of reclaimed tidal flat by alternating seawater inundation and air drying.

    PubMed

    Guo, Shi-Hong; Liu, Zhen-Ling; Li, Qu-Sheng; Yang, Ping; Wang, Li-Li; He, Bao-Yan; Xu, Zhi-Min; Ye, Jin-Shao; Zeng, Eddy Y

    2016-08-01

    Leaching experiments were conducted in a greenhouse to simulate seawater leaching combined with alternating seawater inundation and air drying. We investigated the heavy metal release of soils caused by changes associated with seawater inundation/air drying cycles in the reclaimed soils. After the treatment, the contents of all heavy metals (Cd, Pb, Cr, and Cu), except Zn, in surface soil significantly decreased (P < 0.05), with removal rates ranging from 10% to 51%. The amounts of the exchangeable, carbonate, reducible, and oxidizable fractions also significantly decreased (P < 0.05). Moreover, prolonged seawater inundation enhanced the release of heavy metals. Measurement of diffusive gradients in thin films indicated that seawater inundation significantly increased the re-mobility of heavy metals. During seawater inundation, iron oxide reduction induced the release of heavy metals in the reducible fraction. Decomposition of organic matter, and complexation with dissolved organic carbon decreased the amount of heavy metals in the oxidizable fraction. Furthermore, complexation of chloride ions and competition of cations during seawater inundation and/or leaching decreased the levels of heavy metals in the exchangeable fraction. By contrast, air drying significantly enhanced the concentration of heavy metals in the exchangeable fraction. Therefore, the removal of heavy metals in the exchangeable fraction can be enhanced during subsequent leaching with seawater. PMID:27236846

  19. Low-cost monitoring of Campylobacter in poultry houses by air sampling and quantitative PCR.

    PubMed

    Søndergaard, M S R; Josefsen, M H; Löfström, C; Christensen, L S; Wieczorek, K; Osek, J; Hoorfar, J

    2014-02-01

    The present study describes the evaluation of a method for the quantification of Campylobacter by air sampling in poultry houses. Sampling was carried out in conventional chicken houses in Poland, in addition to a preliminary sampling in Denmark. Each measurement consisted of three air samples, two standard boot swab fecal samples, and one airborne particle count. Sampling was conducted over an 8-week period in three flocks, assessing the presence and levels of Campylobacter in boot swabs and air samples using quantitative real-time PCR. The detection limit for air sampling was approximately 100 Campylobacter cell equivalents (CCE)/m3. Airborne particle counts were used to analyze the size distribution of airborne particles (0.3 to 10 μm) in the chicken houses in relation to the level of airborne Campylobacter. No correlation was found. Using air sampling, Campylobacter was detected in the flocks right away, while boot swab samples were positive after 2 weeks. All samples collected were positive for Campylobacter from week 2 through the rest of the rearing period for both sampling techniques, although levels 1- to 2-log CCE higher were found with air sampling. At week 8, the levels were approximately 10(4) and 10(5) CCE per sample for boot swabs and air, respectively. In conclusion, using air samples combined with quantitative real-time PCR, Campylobacter contamination could be detected earlier than by boot swabs and was found to be a more convenient technique for monitoring and/or to obtain enumeration data useful for quantitative risk assessment of Campylobacter. PMID:24490929

  20. Neutral and ionic per- and polyfluoroalkyl substances (PFASs) in atmospheric and dry deposition samples over a source region (Tianjin, China).

    PubMed

    Yao, Yiming; Chang, Shuai; Sun, Hongwen; Gan, Zhiwei; Hu, Hongwei; Zhao, Yangyang; Zhang, Yufen

    2016-05-01

    Per- and polyfluoroalkyl substances (PFASs) were detected in the atmosphere of a source region in Tianjin, China. Fluorotelomer alcohols (FTOHs) were the dominant neutral PFASs in the atmosphere with total concentrations of 93.6-131 pg/m(3) and 8:2 FTOH contributing the most, whereas perfluorooctane sulfonamide derivatives (PFOSAs) were two magnitudes lower or undetected. In comparison, ionic PFASs (perfluoroalkyl carboxyl acids (PFCAs)) in the atmosphere were detected at similar or even higher levels. At wastewater treatment plants (WWTPs), the air over influent was found with higher levels of FTOHs than over aeration tank and effluent; whereas in the air over the aeration tank, the concentrations of PFOSAs and nonvolatile ionic PFASs substantially increased, suggesting a possible direct release of ionic PFASs to the atmosphere besides the atmospheric conversion from volatile precursors. In the air phase, a low proportion (1-5%) of PFCAs was subjected to dry deposition in the source region. Interestingly, the dry-deposition-to-bulk-air ratios of PFCA analogues were the lowest at medium chain lengths (C8 and C9) and increased with either shorter or longer chain length. The extraordinary affinity of shorter-chain PFCAs (C6-C7) to particles was presumed to be due to their smaller molecular size favoring the interactions between the carboxyl head groups and specific sorption sites on particulate matter. PMID:26952273

  1. Quantitation of trace metals in liquid samples by dried-droplet laser ablation inductively coupled plasma mass spectrometry.

    PubMed

    Yang, Lu; Sturgeon, Ralph E; Mester, Zoltán

    2005-05-01

    A new, discrete sample introduction approach based on laser ablation (LA) is described for the quantitation of several trace metals in aqueous samples by ICPMS. Dried microdroplets of sample, previously mixed with a sodium acetate matrix, were quantitatively ablated from a polystyrene substrate. Calibration via the method of standard additions or isotope dilution provided accurate results for Ni, Cd, and Pb in drinking water and Se in a yeast extract. Compared to conventional solution nebulization, LA sample introduction provided a 2-7-fold enhancement in absolute sensitivity and transport efficiency of 2-14% for the elements examined. Estimated detection limits are 1-7-fold poorer for the dried-droplet LA technique, primarily a result of degraded precision arising from counting statistics limitations for discrete sample introduction. On the basis of the several-second half-width of the resulting transient signals, sample throughput can be in the range of 250 samples per hour. Additionally, integration of the transient signal should eliminate contributions to elemental fractionation from the LA step. Dried-droplet LA-ICPMS offers several advantages over its counterpart, ETV-ICPMS, with respect to background intensity, throughput, and ease of desorption. PMID:15859618

  2. Recovery of viable non-culturable dry stressed Campylobacter jejuni from inoculated samples utilizing a chick bioassay

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Studies have shown that stressed Campylobacter cells in aquatic environments can be viable non-culturable. Preliminary experiments have shown in a matter of hours, certain Campylobacter jejuni strains are not readily recovered from dry stressed samples by current methodology procedures. The object...

  3. Porous filtering media comparison through wet and dry sampling of fixed bed gasification products

    NASA Astrophysics Data System (ADS)

    Allesina, G.; Pedrazzi, S.; Montermini, L.; Giorgini, L.; Bortolani, G.; Tartarini, P.

    2014-11-01

    The syngas produced by fixed bed gasifiers contains high quantities of particulate and tars. This issue, together with its high temperature, avoids its direct exploitation without a proper cleaning and cooling process. In fact, when the syngas produced by gasification is used in an Internal Combustion engine (IC), the higher the content of tars and particulate, the higher the risk to damage the engine is. If these compounds are not properly removed, the engine may fail to run. A way to avoid engine fails is to intensify the maintenance schedule, but these stops will reduce the system profitability. From a clean syngas does not only follow higher performance of the generator, but also less pollutants in the atmosphere. When is not possible to work on the gasification reactions, the filter plays the most important role in the engine safeguard process. This work is aimed at developing and comparing different porous filters for biomass gasifiers power plants. A drum filter was developed and tested filling it with different filtering media available on the market. As a starting point, the filter was implemented in a Power Pallet 10 kW gasifier produced by the California-based company "ALL Power Labs". The original filter was replaced with different porous biomasses, such as woodchips and corn cobs. Finally, a synthetic zeolites medium was tested and compared with the biological media previously used. The Tar Sampling Protocol (TSP) and a modified "dry" method using the Silica Gel material were applied to evaluate the tars, particulate and water amount in the syngas after the filtration process. Advantages and disadvantages of every filtering media chosen were reported and discussed.

  4. Dried venous blood samples for the detection and quantification of measles IgG using a commercial enzyme immunoassay.

    PubMed Central

    Riddell, Michaela A.; Byrnes, Graham B.; Leydon, Jennie A.; Kelly, Heath A.

    2003-01-01

    OBJECTIVES: To determine whether samples of dried venous blood (DVB) were an acceptable alternative to serum for detecting measles-specific IgG in a commercial enzyme immunoassay. METHODS: Paired samples of serum and DVB were collected from 98 suspected cases of measles and 1153 schoolchildren in Victoria, Australia. All samples were tested using the Dade Behring Enzygnost Anti-Measles-Virus/IgG immunoassay. DVB samples were eluted using either the sample buffer provided with the kit or 5% dry milk powder in phosphate-buffered saline-Tween 20. FINDINGS: DVB samples eluted by sample buffer showed significantly better linear correlation to the serum samples than did DVB samples eluted in 5% dry milk in phosphate-buffered saline-Tween 20. To improve the comparability of serum and DVB samples an adjustment factor of 1.28 was applied to the optical density (OD) values of DVB. This adjustment also enabled quantification of the titre of measles IgG in mIU/ml directly from the OD value using the alpha calculation as specified by the kit protocol. For DVB samples stored for less than six months at 4 degrees C, the assay showed an overall sensitivity of 98.4% and a specificity of 97.2% compared with the results of serum testing. CONCLUSION: These results illustrate the potential for DVB samples to be widely used with the Dade Behring enzyme immunoassay system for determining the immunity of the individual and the population to the measles virus. PMID:14758429

  5. Influence of drying by convective air dryer or power ultrasound on the vitamin C and β-carotene content of carrots.

    PubMed

    Frias, Juana; Peñas, Elena; Ullate, Mónica; Vidal-Valverde, Concepción

    2010-10-13

    Convective air drying and power ultrasound effects on vitamin C and β-carotene contents in carrots were studied. For convective air drying, a central composite face-centered design fitting temperature between 40 and 65 °C and air flow rate between 2 and 6 × 10(-1) m/s were used; previously, carrots were blanched. Likewise, ultrasound drying was performed on both unblanched and blanched carrots at 20, 40, and 60 °C for 120, 90, and 75 min, respectively. Blanching had a sharp effect on vitamin C and β-carotene degradation (80-92% retentions, respectively), and convective air drying led to further losses (32-50% and 73-90% retentions, respectively). According to the response surface model, a combination of 40 °C and 6 × 10(-1) m/s will maximize vitamin C retention in dried carrots, whereas 40 °C and 3.3 × 10(-1) m/s will ensure the highest β-carotene content. Ultrasound drying caused higher vitamin C and β-carotene retention (82-92% and 96-98%, respectively) than convective air drying. Blanched carrots dehydrated by ultrasound showed retentions of 55% and 88% of vitamin C and β-carotene, respectively. Ultrasound drying at 20 °C for 120 min caused the maximum vitamin C and β-carotene contents. Therefore, power ultrasound may be considered a valuable tool to obtain high nutritive dehydrated carrots. PMID:20843024

  6. Three air quality studies: Great Lakes ozone formation and nitrogen dry deposition; and Tucson aerosol chemical characterization

    NASA Astrophysics Data System (ADS)

    Foley, Theresa

    (arsenic, beryllium, cadmium, chromium, cobalt, lead, manganese, and nickel) in the southern Tucson metropolitan area. A Tucson company that uses beryllium oxide to manufacture thermally conductive ceramics has prompted strong citizen concern. This study found that the study area has good air quality with respect to PM10 and metals, with ambient concentrations meeting US Environmental Protection Agency and World Health Organization standards. Beryllium was detected only once (during a dust storm) and was ascribed to naturally-occurring beryllium in the suspended soil. The third paper (to be submitted to the Journal of Great Lakes Research) studies nitrogen dry deposition over Lake Michigan and Lake Superior. Numerous studies have shown that wet and dry deposition of nitrogen has contributed to the eutrophication of coastal waters and declining productivity of marine fisheries. Nitrogen dry deposition over the Great Lakes themselves, as opposed to the shorelines, has not been documented in the peer-reviewed literature. This paper calculates nitrogen dry deposition over Lake Michigan and Lake Superior, using aircraft measurements from the LADCO Aircraft Study, and finds that over-water, nitrogen dry deposition is a significant source of nitrogen to Lake Michigan and Lake Superior.

  7. Comparison of stationary and personal air sampling with an air dispersion model for children's ambient exposure to manganese.

    PubMed

    Fulk, Florence; Haynes, Erin N; Hilbert, Timothy J; Brown, David; Petersen, Dan; Reponen, Tiina

    2016-09-01

    Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to assess exposure for children enrolled in the Communities Actively Researching Exposure Study in Marietta, OH. Ambient air Mn concentration values were modeled using US Environmental Protection Agency's Air Dispersion Model AERMOD based on emissions from the ferromanganese refinery located in Marietta. Modeled Mn concentrations were compared with Mn concentrations from a nearby stationary air monitor. The Index of Agreement for modeled versus monitored data was 0.34 (48 h levels) and 0.79 (monthly levels). Fractional bias was 0.026 for 48 h levels and -0.019 for monthly levels. The ratio of modeled ambient air Mn to measured ambient air Mn at the annual time scale was 0.94. Modeled values were also time matched to personal air samples for 19 children. The modeled values explained a greater degree of variability in personal exposures compared with time-weighted distance from the emission source. Based on these results modeled Mn concentrations provided a suitable approach for assessing airborne Mn exposure in this cohort. PMID:27168393

  8. Detection of the Urban Release of a Bacillus anthracis Simulant by Air Sampling

    PubMed Central

    Garza, Alexander G.; Van Cuyk, Sheila M.; Brown, Michael J.

    2014-01-01

    In 2005 and 2009, the Pentagon Force Protection Agency (PFPA) staged deliberate releases of a commercially available organic pesticide containing Bacillus amyloliquefaciens to evaluate PFPA's biothreat response protocols. In concert with, but independent of, these releases, the Department of Homeland Security sponsored experiments to evaluate the efficacy of commonly employed air and surface sampling techniques for detection of an aerosolized biological agent. High-volume air samplers were placed in the expected downwind plume, and samples were collected before, during, and after the releases. Environmental surface and personal air samples were collected in the vicinity of the high-volume air samplers hours after the plume had dispersed. The results indicate it is feasible to detect the release of a biological agent in an urban area both during and after the release of a biological agent using high-volume air and environmental sampling techniques. PMID:24697146

  9. Detection of the urban release of a bacillus anthracis simulant by air sampling.

    PubMed

    Garza, Alexander G; Van Cuyk, Sheila M; Brown, Michael J; Omberg, Kristin M

    2014-01-01

    In 2005 and 2009, the Pentagon Force Protection Agency (PFPA) staged deliberate releases of a commercially available organic pesticide containing Bacillus amyloliquefaciens to evaluate PFPA's biothreat response protocols. In concert with, but independent of, these releases, the Department of Homeland Security sponsored experiments to evaluate the efficacy of commonly employed air and surface sampling techniques for detection of an aerosolized biological agent. High-volume air samplers were placed in the expected downwind plume, and samples were collected before, during, and after the releases. Environmental surface and personal air samples were collected in the vicinity of the high-volume air samplers hours after the plume had dispersed. The results indicate it is feasible to detect the release of a biological agent in an urban area both during and after the release of a biological agent using high-volume air and environmental sampling techniques. PMID:24697146

  10. Review of the Physical Science Facility Stack Air Sampling Probe Locations

    SciTech Connect

    Glissmeyer, John A.

    2007-09-30

    This letter report reviews compliance of the current design of the Physical Science Facility (PSF) stack air sampling locations with the ANSI/HPS N13.1-1999 standard. The review was based on performance criteria used for locating air sampling probes, the design documents provided and available information on systems previously tested for compliance with the criteria. Recommendations are presented for ways to bring the design into compliance with the requirements for the sampling probe placement.

  11. Amino acid preservation in saline halite core samples: Analogs for Martian dry evaporitic regions

    NASA Astrophysics Data System (ADS)

    Bada, J.; Aubrey, A.; Lowenstein, T.; Timofeeff, M.

    2008-12-01

    in the deepest core section. This may indicate some recent amino acid contribution to the pool of certain amino acids. Racemization rates can be calculated from the equation: ln[(1+D/L)/(1-D/L)] - ln [(1+D/L)/(1-D/L)]t=0 = 2ki(time) where ki is the first-order rate constant for the interconversion of the enantiomers. Using the D/L ratios at the top of the core for the t = 0 term gives kasp = 3.5x10exp-5 y-1 and 1.3x10exp-5 y-1 for the 18 and 70 ka samples, respectively. For valine, the values are kval = 5.6x10exp-6 y-1 and 7.3x10exp-6 y-1. Extrapolating these values to the average surface temperatures on Mars indicates that the chirality of these amino acids would be preserved for billions of years. Thus, closed basin lacustrine and dry desert valley regions with evaporite-rich deposits are suitable environments in the search for preserved biosignatures on Mars. References [1] Bibring, J.P., et al., Science 307, 1576 (2005) [2] Klinghofer, G., et al., Science 306, 1740 (2004) [3] Osterloo, M.M., et al., Science 319, 1651 (2008) [4] Squyres, S.W., et al., Nature 443, E1 (2006) [5] Lowenstein, T.K., et al., Geology 27, 3 (1999) [6] Glavin, D., et al., Earth Planet. Sci. Lett. 185,1 (2001) [7] Aubrey, A. D., et al., in preparation, Nature Geo. Sci.

  12. Air classifier technology (ACT) in dry powder inhalation Part 3. Design and development of an air classifier family for the Novolizer multi-dose dry powder inhaler.

    PubMed

    de Boer, A H; Hagedoorn, P; Gjaltema, D; Goede, J; Frijlink, H W

    2006-03-01

    In this study, the design of a multifarious classifier family for different applications is described. The main design and development steps are presented as well as some special techniques that have been applied to achieve preset objectives. It is shown by increasing the number of air supply channels to the classifier chamber (from 2 to 8), that the fine particle losses from adhesion onto the classifier walls can be reduced from 75% to less than 5% of the real dose for soft (spherical) agglomerates. By applying a bypass flow that is arranged as a co-axial sheath of clean air around the aerosol cloud from the classifier, the airflow resistance of the classifier can be controlled over a relatively wide range of values (0.023-0.041 kPa(0.5) min l(-1)). This, without affecting the fine particle dose or increasing the fine particle losses in the inhaler. Moreover, the sheath flow can be modelled to reduce the depositions in the induction port to the cascade impactor or in the patient's mouth, which are the result of back flows in these regions. The principle of powder induced pressure drop reduction across a classifier enables assessment of the amount of powder in the classifier at any moment during inhalation, from which classifier loading (from the dose system) and discharge rates can be derived. This principle has been applied to study the residence time of a dose in the classifier as function of the carrier size fraction and the flow rate. It has been found that this residence time can be controlled in order to obtain an optimal balance between the generated fine particle fraction and the inhalation manoeuvre of the patient. A residence time between 0.5 and 2 s at 60 l/min is considered favourable, as this yields a high fine particle dose (depending on the type of formulation used) and leaves sufficient inhaled volume for particle transport into the deep lung. PMID:16442248

  13. Identification of ambient air sampling and analysis methods for the 189 Title III air toxics

    SciTech Connect

    Mukund, R.; Kelly, T.J.; Gordon, S.M.; Hays, M.J.

    1994-12-31

    The state of development of ambient air measurement methods for the 189 Hazardous Air Pollution (HAPs) in Title 3 of the Clean Air Act Amendments was surveyed. Measurement methods for the HAPs were identified by reviews of established methods, and by literature searches for pertinent research techniques. Methods were segregated by their degree of development into Applicable, Likely, and Potential methods. This survey identified a total of 183 methods, applicable at varying degrees to ambient air measurements of one or more HAPs. As a basis for classifying the HAPs and evaluating the applicability of measurement methods, a survey of a variety of chemical and physical properties of the HAPs was also conducted. The results of both the methods and properties surveys were tabulated for each of the 189 HAP. The current state of development of ambient measurement methods for the 189 HAPs was then assessed from the results of the survey, and recommendations for method development initiatives were developed.

  14. SOURCE ASSESSMENT: DRY BOTTOM INDUSTRIAL BOILERS FIRING PULVERIZED BITUMINOUS COAL

    EPA Science Inventory

    The report describes and assesses the potential impact of air emissions, wastewater effluents, and solid wastes from the operation of dry bottom industrial boilers firing pulverized bituminous coal. Air emissions were characterized by a literature survey and field sampling. Signi...

  15. Study of PCBs and PBDEs in King George Island, Antarctica, using PUF passive air sampling

    NASA Astrophysics Data System (ADS)

    Li, Yingming; Geng, Dawei; Liu, Fubin; Wang, Thanh; Wang, Pu; Zhang, Qinghua; Jiang, Guibin

    2012-05-01

    Polyurethane foam (PUF)-disk based passive air samplers were deployed in King George Island, Antarctica, during the austral summer of 2009-2010, to investigate levels, distributions and potential sources of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in Antarctic air. The atmospheric levels of ∑ indicator PCBs and ∑14 PBDEs ranged from 1.66 to 6.50 pg m-3 and from 0.67 to 2.98 pg m-3, respectively. PCBs homologue profiles were dominated by di-PCBs, tri-PCBs and tetra-PCBs, whereas BDE-17 and BDE-28 were the predominant congeners of PBDEs, which could be explained by long-range atmospheric transport processes. However, the sampling sites close to the Antarctic research stations showed higher atmospheric concentrations of PCBs and PBDEs than the other sites, reflecting potential local sources from the Antarctic research stations. The non-Aroclor congener PCB-11 was found in all the air samples, with air concentrations of 3.60-31.4 pg m-3 (average 15.2 pg m-3). Comparison between the results derived from PUF-disk passive air sampling and high-volume air sampling validates the feasibility of using the passive air samplers in Antarctic air. To our knowledge, this study is the first employment of PUF-disk based passive air samplers in Antarctic atmosphere.

  16. Summary of gamma spectrometry on local air samples from 1985--1995

    SciTech Connect

    Winn, W.G.

    1997-04-02

    This report summarizes the 1985--1995 results of low-level HPGe gamma spectrometry analysis of high-volume air samples collected at the Aiken Airport, which is about 25 miles north of SRS. The author began analyzing these samples with new calibrations using the newly developed GRABGAM code in 1985. The air sample collections were terminated in 1995, as the facilities at the Aiken Airport were no longer available. Air sample measurements prior to 1985 were conducted with a different analysis system (and by others prior to 1984), and the data were not readily available. The report serves to closeout this phase of local NTS air sample studies, while documenting the capabilities and accomplishments. Hopefully, the information will guide other applications for this technology, both locally and elsewhere.

  17. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks

    NASA Astrophysics Data System (ADS)

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL- 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  18. Adsorption of peptides at the sample drying step: influence of solvent evaporation technique, vial material and solution additive.

    PubMed

    Pezeshki, Adel; Vergote, Valentijn; Van Dorpe, Sylvia; Baert, Bram; Burvenich, Christian; Popkov, Alexander; De Spiegeleer, Bart

    2009-04-01

    Although the efficient and careful removal of solvent from samples by centrifugal evaporation or freeze-drying methods is an important step in peptidomics, the recovery of peptides has not yet been fully investigated with these sample drying methods. Moreover, the surface adsorption of the peptides by the container and efforts to reduce this adsorption by organic additives is only scarcely elaborated until now. In this experiment, the recovery of five model peptides, i.e. bovine insulin, mouse obestatin, goserelin, buserelin and leucine-enkephalin was investigated applying dimethylsulfoxide (DMSO), dimethylformamide (DMF), polyethylene glycol 400 (PEG 400), mannitol and n-nonyl-beta-d-glucopyranoside (C(9)-Glu) in function of the two applied solvent evaporation processes (freeze-drying vs. centrifugal evaporation) and vial types, i.e. polypropylene (PP) and glass. Under our experimental conditions, drying resulted in a decreased recovery of the model peptides by 10% on average. Insulin showed the lowest recovery value relative to the other model peptides. For both drying methods, recovery of the model peptides was increased when C(9)-Glu was present. Overall, the use of PP vials is proposed for freeze-drying, while glass vials are found to be more suitable for centrifugal evaporation. The presence of PEG 400 in PP vials caused significantly reduced recoveries for all model peptides using centrifugal evaporation, although this was not observed in glass vials. As a general conclusion, applying C(9)-Glu as an additive along with choosing appropriate vial type (i.e. PP for lyophilization and glass for centrifugal evaporation) can avoid or diminish peptide loss during the evaporation procedure. PMID:19150589

  19. A method to optimize sampling locations for measuring indoor air distributions

    NASA Astrophysics Data System (ADS)

    Huang, Yan; Shen, Xiong; Li, Jianmin; Li, Bingye; Duan, Ran; Lin, Chao-Hsin; Liu, Junjie; Chen, Qingyan

    2015-02-01

    Indoor air distributions, such as the distributions of air temperature, air velocity, and contaminant concentrations, are very important to occupants' health and comfort in enclosed spaces. When point data is collected for interpolation to form field distributions, the sampling locations (the locations of the point sensors) have a significant effect on time invested, labor costs and measuring accuracy on field interpolation. This investigation compared two different sampling methods: the grid method and the gradient-based method, for determining sampling locations. The two methods were applied to obtain point air parameter data in an office room and in a section of an economy-class aircraft cabin. The point data obtained was then interpolated to form field distributions by the ordinary Kriging method. Our error analysis shows that the gradient-based sampling method has 32.6% smaller error of interpolation than the grid sampling method. We acquired the function between the interpolation errors and the sampling size (the number of sampling points). According to the function, the sampling size has an optimal value and the maximum sampling size can be determined by the sensor and system errors. This study recommends the gradient-based sampling method for measuring indoor air distributions.

  20. Improved Formulations for Air-Surface Exchanges Related to National Security Needs: Dry Deposition Models

    SciTech Connect

    Droppo, James G.

    2006-07-01

    The Department of Homeland Security and others rely on results from atmospheric dispersion models for threat evaluation, event management, and post-event analyses. The ability to simulate dry deposition rates is a crucial part of our emergency preparedness capabilities. Deposited materials pose potential hazards from radioactive shine, inhalation, and ingestion pathways. A reliable characterization of these potential exposures is critical for management and mitigation of these hazards. A review of the current status of dry deposition formulations used in these atmospheric dispersion models was conducted. The formulations for dry deposition of particulate materials from am event such as a radiological attack involving a Radiological Detonation Device (RDD) is considered. The results of this effort are applicable to current emergency preparedness capabilities such as are deployed in the Interagency Modeling and Atmospheric Assessment Center (IMAAC), other similar national/regional emergency response systems, and standalone emergency response models. The review concludes that dry deposition formulations need to consider the full range of particle sizes including: 1) the accumulation mode range (0.1 to 1 micron diameter) and its minimum in deposition velocity, 2) smaller particles (less than .01 micron diameter) deposited mainly by molecular diffusion, 3) 10 to 50 micron diameter particles deposited mainly by impaction and gravitational settling, and 4) larger particles (greater than 100 micron diameter) deposited mainly by gravitational settling. The effects of the local turbulence intensity, particle characteristics, and surface element properties must also be addressed in the formulations. Specific areas for improvements in the dry deposition formulations are 1) capability of simulating near-field dry deposition patterns, 2) capability of addressing the full range of potential particle properties, 3) incorporation of particle surface retention/rebound processes, and

  1. Evaluation of the desiccation tolerance of blastospores of Paecilomyces fumosoroseus (Deuteromycotina: Hyphomyces)using a lab- scale, air-drying chamber with controlled relative humidity

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The stabilization of living microbial agents for use as biological control agents is often accomplished through desiccation. The drying process must be conducive to the survival of the living microbial agent during desiccation and storage. Our air-drying studies with liquid culture-produced blasto...

  2. Soil water retention at varying matric potentials following repeated wetting with modestly saline-sodic water and subsequent air drying

    SciTech Connect

    Browning, L.S.; Hershberger, K.R.; Bauder, J.W.

    2007-07-01

    Coal bed natural gas (CBNG) development in the Powder River (PR) Basin produces modestly saline, highly sodic wastewater. This study assessed impacts of wetting four textural groups (0-11%, 12-22%, 23 -33%, and > 33% clay (g clay/100 g soil) x 100%))with simulated PR or CBNG water on water retention. Soils received the following treatments with each water quality: a single wetting event, five wetting and drying events, or five wetting and drying events followed by leaching with salt-free water. Treated samples were then resaturated with the final treatment water and equilibrated to -10, -33, -100, -500, or -1,500 kPa. At all potentials, soil water retention increased significantly with increasing clay content. Drought-prone soils lost water-holding capacity between saturation and field capacity with repeated wetting and drying, whereas finer textured soils withstood this treatment better and had increased water-retention capacity at lower matric potentials.

  3. Dry under water: comparative morphology and functional aspects of air-retaining insect surfaces.

    PubMed

    Balmert, Alexander; Florian Bohn, Holger; Ditsche-Kuru, Petra; Barthlott, Wilhelm

    2011-04-01

    Superhydrophobic surfaces prevent certain body parts of semiaquatic and aquatic insects from getting wet while submerged in water. The air layer on these surfaces can serve the insects as a physical gill. Using scanning electron microscopy, we investigated the morphology of air-retaining surfaces in five insect species with different levels of adaptation to aquatic habitats. We found surfaces with either large and sparse hairs (setae), small and dense hairs (microtrichia), or hierarchically structured surfaces with both types of hairs. The structural parameters and air-film persistence of these surfaces were compared. Air-film persistence varied between 2 days in the beetle Galerucella nymphaea possessing only sparse setae and more than 120 days in the bugs Notonecta glauca and Ilyocoris cimicoides possessing dense microtrichia (up to 6.6 × 10(6) microtrichia per millimeter square). From our results, we conclude that the density of the surface structures is the most important factor that affects the persistence of air films. Combinations of setae and microtrichia are not decisive for the overall persistence of the air film but might provide a thick air store for a short time and a thin but mechanically more stable air film for a long time. Thus, we assume that a dense cover of microtrichia acts as a "backup system" preventing wetting of the body surface in case the air-water interface is pressed toward the surface. Our findings might be beneficial for the development of biomimetic surfaces for long-term air retention and drag reduction under water. In addition, the biological functions of the different air retention capabilities are discussed. PMID:21290417

  4. A STRINGENT COMPARISON OF SAMPLING AND ANALYSIS METHODS FOR VOCS IN AMBIENT AIR

    EPA Science Inventory

    A carefully designed study was conducted during the summer of 1998 to simultaneously collect samples of ambient air by canisters and compare the analysis results to direct sorbent preconcentration results taken at the time of sample collection. A total of 32 1-h sample sets we...

  5. A METHOD FOR THE SAMPLING AND ANALYSIS OF POLYCHLORINATED BIPHENYLS (PCBS) IN AMBIENT AIR

    EPA Science Inventory

    A method was developed for the sampling and analysis of polychlorinated biphenyls (PCBs) in air. An easily constructed, high-volume sampling system is employed with porous polyurethane foam as the collection medium. The sample is collected at the rate of 0.6 to 1.0 cu m per minut...

  6. Mixed species radioiodine air sampling readout and dose assessment system

    DOEpatents

    Distenfeld, Carl H.; Klemish, Jr., Joseph R.

    1978-01-01

    This invention provides a simple, reliable, inexpensive and portable means and method for determining the thyroid dose rate of mixed airborne species of solid and gaseous radioiodine without requiring highly skilled personnel, such as health physicists or electronics technicians. To this end, this invention provides a means and method for sampling a gas from a source of a mixed species of solid and gaseous radioiodine for collection of the mixed species and readout and assessment of the emissions therefrom by cylindrically, concentrically and annularly molding the respective species around a cylindrical passage for receiving a conventional probe-type Geiger-Mueller radiation detector.

  7. Dispersion modeling of selected PAHs in urban air: A new approach combining dispersion model with GIS and passive air sampling

    NASA Astrophysics Data System (ADS)

    Sáňka, Ondřej; Melymuk, Lisa; Čupr, Pavel; Dvorská, Alice; Klánová, Jana

    2014-10-01

    This study introduces a new combined air concentration measurement and modeling approach that we propose can be useful in medium and long term air quality assessment. A dispersion study was carried out for four high molecular weight polycyclic aromatic hydrocarbons (PAHs) in an urban area with industrial, traffic and domestic heating sources. A geographic information system (GIS) was used both for processing of input data as well as visualization of the modeling results. The outcomes of the dispersion model were compared to the results of passive air sampling (PAS). Despite discrepancies between measured and modeled concentrations, an approach combining the two techniques is promising for future air quality assessment. Differences between measured and modeled concentrations, in particular when measured values exceed the modeled concentrations, are indicative of undocumented, sporadic pollutant sources. Thus, these differences can also be useful for assessing and refining emission inventories.

  8. Automated syringe sampler. [remote sampling of air and water

    NASA Technical Reports Server (NTRS)

    Purgold, G. C. (Inventor)

    1981-01-01

    A number of sampling services are disposed in a rack which slides into a housing. In response to a signal from an antenna, the circutry elements are activated which provide power individually, collectively, or selectively to a servomechanism thereby moving an actuator arm and the attached jawed bracket supporting an evaculated tube towards a stationary needle. One open end of the needle extends through the side wall of a conduit to the interior and the other open end is maintained within the protective sleeve, supported by a bifurcated bracket. A septum in punctured by the end of the needle within the sleeve and a sample of the fluid medium in the conduit flows through the needle and is transferred to a tube. The signal to the servo is then reversed and the actuator arm moves the tube back to its original position permitting the septum to expand and seal the hole made by the needle. The jawed bracket is attached by pivot to the actuator to facilitate tube replacement.

  9. Decorin content and near infrared spectroscopy analysis of dried collagenous biomaterial samples

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The efficient removal of proteoglycans, such as decorin, from hide when processing it traditionally to leather is generally acceptable and beneficial for leather quality, especially for softness and flexibility. The objective of this research was to determine the residual decorin content of dried c...

  10. Rapid high throughput amylose determination in freeze dried potato tuber samples

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Approximately 80% of the fresh weight of a potato tuber is water; nearly all of the remaining dry matter is starch. Most of the starch (70%) is composed of amylopectin, while the remainder is amylose. The ratio between amylose and amylopectin is the most important property influencing the physical p...

  11. Predicting seed cotton moisture content from changes in drying air temperature - second year

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A mathematical model was used to predict seed cotton moisture content in the overhead section of a cotton gin. The model took into account the temperature, mass flow, and specific heat of both the air and seed cotton. Air temperatures and mass flows were measured for a second year at a commercial g...

  12. Salmonella recovery following air chilling for matched neck-skin and whole carcass sampling methodologies

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The prevalence and serogroups of Salmonella recovered following air chilling were determined for both enriched neck skin and matching enriched whole carcass samples. Commercially processed and eviscerated carcasses were air chilled to 4C before removing the neck skin (8.3 g) and stomaching in 83 mL...

  13. Trapping Efficiency of 1,3-Dichloropropene Isomers by XAD-4 Sorbent Tubes for Air Sampling

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Emission monitoring is necessary to evaluate the impact of air pollutants such as soil fumigants on the environment. Quantifying fumigant emissions often involves the use of air sampling tubes filled with sorbents to trap fumigants. 1,3-dichloropropene (1,3-D) and chloropicrin (CP) are being increas...

  14. FIELD EVALUATION OF SAMPLING AND ANALYSIS FOR ORGANIC POLLUTANTS IN INDOOR AIR

    EPA Science Inventory

    The objectives of the study were to determine the feasibility of the use of newly developed indoor air samplers in residential indoor air sampling and to evaluate methodology for characterization of the concentrations of polynuclear aromatic hydrocarbons (PAH), PAH derivatives, a...

  15. Sampling and Analyzing Air Pollution: An Apparatus Suitable for Use in Schools.

    ERIC Educational Resources Information Center

    Rockwell, Dean M.; Hansen, Tony

    1994-01-01

    Describes two variations of an air sampler and analyzer that are inexpensive to construct, easy to operate, and designed to be used in an educational program. Variations use vacuum cleaners and aquarium pumps, and white facial tissues serve as filters. Samples of air pollution obtained by this method may be used from early grade school to advanced…

  16. Top-Down Proteomics and Direct Surface Sampling of Neonatal Dried Blood Spots: Diagnosis of Unknown Hemoglobin Variants

    NASA Astrophysics Data System (ADS)

    Edwards, Rebecca L.; Griffiths, Paul; Bunch, Josephine; Cooper, Helen J.

    2012-11-01

    We have previously shown that liquid microjunction surface sampling of dried blood spots coupled with high resolution top-down mass spectrometry may be used for screening of common hemoglobin variants HbS, HbC, and HbD. In order to test the robustness of the approach, we have applied the approach to unknown hemoglobin variants. Six neonatal dried blood spot samples that had been identified as variants, but which could not be diagnosed by current screening methods, were analyzed by direct surface sampling top-down mass spectrometry. Both collision-induced dissociation and electron transfer dissociation mass spectrometry were employed. Four of the samples were identified as β-chain variants: two were heterozygous Hb D-Iran, one was heterozygous Hb Headington, and one was heterozygous Hb J-Baltimore. The fifth sample was identified as the α-chain variant heterozygous Hb Phnom Penh. Analysis of the sixth sample suggested that it did not in fact contain a variant. Adoption of the approach in the clinic would require speed in both data collection and interpretation. To address that issue, we have compared manual data analysis with freely available data analysis software (ProsightPTM). The results demonstrate the power of top-down proteomics for hemoglobin variant analysis in newborn samples.

  17. Results of a Self-Absorption Study on the Versapor 3000 47-mm Filters for Radioactive Particulate Air Stack Sampling

    SciTech Connect

    Barnett, J. Matthew; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-11-01

    Since the mid-1980s the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor® 3000, 47-mm diameter) used at PNNL for self absorption effects. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Large error is associated with the sample filter analysis comparison and subsequently with the estimation of the absorption factor resulting in an inadequate method to estimate losses from self-absorption in the sample filter. The mass loading on the sample filter as determined after digestion and drying was ~0.08 mg cm-2; however, this value may not represent the total filter mass loading given that there may be undetermined losses associated with the digestion process. While it is difficult to determine how much material is imbedded in the filter, observations from the microscopy analysis indicate that the vast majority of the particles remain on the top of the filter. In comparing the results obtained, the continued use of 0.85 as a conservative correction factor is recommended.

  18. Operational air sampling report. [Semiannual report], July 1--December 31, 1993

    SciTech Connect

    Lyons, C.L.

    1994-03-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 118 air samples collected in the only active tunnel complex, only one showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 206 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products.

  19. Operational air sampling report. [Semiannual report], January 1--June 30, 1993

    SciTech Connect

    Lyons, C.L.

    1993-12-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. This report discusses the REECo air sampling program which is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 243 air samples collected in the only active tunnel complex, none showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 246 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products.

  20. EVALUATION OF SAMPLING AND ANALYTICAL METHODOLOGY FOR POLYNUCLEAR AROMATIC COMPOUNDS IN INDOOR AIR

    EPA Science Inventory

    The objective of this project was to develop a generic sampling and analytical methodology to characterize the polynuclear aromatic hydrocarbon (PAH) concentrations in air within various microenvironments. The following three studies were performed: evaluation of analytical metho...

  1. TECHNOLOGY EVALUATION REPORT CEREX ENVIRONMENTAL SERVICES UV HOUND POINT SAMPLE AIR MONITOR

    EPA Science Inventory

    The USEPA's National Homeland Security Research Center (NHSRC) Technology Testing and Evaluation Program (TTEP) is carrying out performance tests on homeland security technologies. Under TTEP, Battelle evaluated the performance of the Cerex UV Hound point sample air monitor in de...

  2. NEW APPLICATION OF PASSIVE SAMPLING DEVICES FOR ASSESSMENT OF RESPIRATORY EXPOSURE TO PESTICIDES IN INDOOR AIR

    EPA Science Inventory

    The United States Environmental Protection Agency (EPA) has long maintained an interest in potential applications of passive sampling devices (PSDs) for estimating the concentrations of various pollutants in air. Typically PSDs were designed for the workplace monitoring of vola...

  3. Bench-scale feasibility testing of pulsed-air technology for in-tank mixing of dry cementitious solids with tank liquids and settled solids

    SciTech Connect

    Whyatt, G.A.; Hymas, C.R.

    1997-09-01

    This report documents the results of testing performed to determine the feasibility of using a pulsed-air mixing technology (equipment developed by Pulsair Systems, Inc., Bellevue, WA) to mix cementitious dry solids with supernatant and settled solids within a horizontal tank. The mixing technology is being considered to provide in situ stabilization of the {open_quotes}V{close_quotes} tanks at the Idaho National Engineering and Environmental Laboratory (INEEL). The testing was performed in a vessel roughly 1/6 the scale of the INEEL tanks. The tests used a fine soil to simulate settled solids and water to simulate tank supernatants. The cementitious dry materials consisted of Portland cement and Aquaset-2H (a product of Fluid Tech Inc. consisting of clay and Portland cement). Two scoping tests were conducted to allow suitable mixing parameters to be selected. The scoping tests used only visual observations during grout disassembly to assess mixing performance. After the scoping tests indicated the approach may be feasible, an additional two mixing tests were conducted. In addition to visual observations during disassembly of the solidified grout, these tests included addition of chemical tracers and chemical analysis of samples to determine the degree of mixing uniformity achieved. The final two mixing tests demonstrated that the pulsed-air mixing technique is capable of producing slurries containing substantially more cementitious dry solids than indicated by the formulations suggested by INEEL staff. Including additional cement in the formulation may have benefits in terms of increasing mobilization of solids, reducing water separation during curing, and increasing the strength of the solidified product. During addition to the tank, the cementitious solids had a tendency to form clumps which broke down with continued mixing.

  4. Comparison of stationary and personal air sampling with an air dispersion model for children’s ambient exposure to manganese

    EPA Science Inventory

    Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to asse...

  5. Dry/wet performance of a plate-fin air-cooled heat exchanger with continuous corrugated fins

    SciTech Connect

    Hauser, S.G.; Kreid, D.K.; Johnson, B.M.

    1981-01-01

    The performance and operating characteristics of a plate-fin heat exchanger in dry/wet or deluge operations was experimentally determined. Development of the deluge heat/mass transfer model continued. The experiments were conducted in a specially-designed wind tunnel at the PNL. Air that was first heated and humidified to specified conditions was circulated at a controlled rate through a 2 ft x 6 ft heat exchanger module. The heat exchanger used in the tests was a wavy surface, plate fin on tube configuration. Hot water was circulated through the tubes at high flow rates to maintain an essentially isothermal condition on the tube side. Deionized water sprayed on the top of the vertically oriented plate fins was collected at the bottom of the core and recirculated. Instrumentation was provided for measurement of flow rates and thermodynamic conditions in the air, in the core circulation water, and in the deluge water. Measurements of the air side pressure drop and heat rejection rate were made as a function of air flow rate, air inlet temperature and humidity, deluge water flow rate, and the core inclination from the vertical. An overall heat transfer coefficient and an effective deluge film convective coefficient was determined. The deluge model, for predicting heat transfer from a wet finned heat exchanger was further developed and refined, and a major extension of the model was formulated that permits simultaneous calculation of both the heat transfer and evaporation rates from the wetted surface. The experiments showed an increase in the heat rejection rate due to wetting, accompanied by a proportional increase in the air side pressure drop. For operation at the same air side pressure drop, the enhancement ratio Q/sub w//Q/sub d/ varied between 2 and 5 for the conditions tested. Thus, the potential enhancement of heat transfer due to wetting can be substantial.

  6. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    PubMed

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration. PMID:21793731

  7. Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study.

    PubMed

    De Kesel, Pieter M M; Lambert, Willy E; Stove, Christophe P

    2015-06-30

    Volumetric absorptive microsampling (VAMS) is a novel sampling technique that allows the straightforward collection of an accurate volume of blood (approximately 10μL) from a drop or pool of blood by dipping an absorbent polymeric tip into it. The resulting blood microsample is dried and analyzed as a whole. The aim of this study was to evaluate the potential of VAMS to overcome the hematocrit bias, an important issue in the analysis of dried blood microsamples. An LC-MS/MS method for analysis of the model compounds caffeine and paraxanthine in VAMS samples was fully validated and fulfilled all pre-established criteria. In conjunction with previously validated procedures for dried blood spots (DBS) and blood, this allowed us to set up a meticulous comparative study in which both compounds were determined in over 80 corresponding VAMS, DBS and liquid whole blood samples. These originated from authentic human patient samples, covering a wide hematocrit range (0.21-0.50). By calculating the differences with reference whole blood concentrations, we found that analyte concentrations in VAMS samples were not affected by a bias that changed over the evaluated hematocrit range, in contrast to DBS results. However, VAMS concentrations tend to overestimate whole blood concentrations, as a consistent positive bias was observed. A different behavior of VAMS samples prepared from incurred and spiked blood, combined with a somewhat reduced recovery of caffeine and paraxanthine from VAMS tips at high hematocrit values, an effect that was not observed for DBS using a very similar extraction procedure, was found to be at the basis of the observed VAMS-whole blood deviations. Based on this study, being the first in which the validity and robustness of VAMS is evaluated by analyzing incurred human samples, it can be concluded that VAMS effectively assists in eliminating the effect of hematocrit. PMID:26041521

  8. Developing hot air assisted radio frequency drying for in-shell Macadamia nuts

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Dehydration offers a means of preserving foods in a stable and safe condition as it reduces water activity and extends shelf-life of perishable agricultural products. The purpose of this study was to develop radio frequency (RF) drying protocols for in-shell macadamia nuts based on conventional hot ...

  9. Predicting seed cotton moisture content from changes in drying air temperature

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Having an accurate measurement of seed-cotton moisture content in a cotton gin would help ginners determine how much heat to use to dry the cotton. A mathematical model was used to predict seed cotton moisture content in the overhead section of a gin. The model took into account the temperature, mas...

  10. Forced Hot Air to Dry Feces and Kill Bacteria on Transport Cage Flooring

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Due to fecal shedding from positive birds, broiler transport cages can be contaminated with human bacterial pathogens leading to cross contamination of previously negative broilers during live haul. Earlier work has shown that drying soiled or washed cages for 24 to 48 hours can lower or even elimi...

  11. Field comparison of air sampling methods for monomeric and polymeric 1,6-hexamethylene diisocyanate.

    PubMed

    Thomasen, Jennifer M; Fent, Kenneth W; Reeb-Whitaker, Carolyn; Whittaker, Stephen G; Nylander-French, Leena A

    2011-03-01

    This study was to critically compared 13 different air samplers for their ability to monitor air exposures to monomeric and polymeric 1,6-hexamethylene diisocyanate (HDI) in the automotive refinishing industry. Using both fast- and slow-drying clearcoat, we tested the following types of samplers: single- and dual-stage 37-mm polypropylene (PP) and polystyrene (PS) samplers (open- and closed-face), IOM (with plastic and stainless steel inserts), OSHA42, IsoChek, and WA-DOSH samplers. Midget impingers with frit were used as reference samplers. We observed the PP, PS, and IOM samplers to measure greater levels of HDI monomer and biuret when a fast-drying clearcoat was applied compared with a slow-drying clearcoat. When a slow-drying clearcoat was applied, the open-face PP and PS samplers measured significantly more monomeric and polymeric HDI (2-fold; p < 0.003) than the closed-face PP and PS samplers. We determined that significantly more monomeric and polymeric HDI were measured by impingers (1.3-1.9-fold) compared with single-stage PP/PS (N = 59), dual-stage PP/PS (N = 59), or IOM (N = 24) samplers. However, when stratified by cassette characteristics, the open-face single-stage PP and PS samplers performed equally to the impingers for HDI monomer when a fast-drying clearcoat was applied, and for all analytes when a slow-drying clearcoat was applied. Significantly higher HDI monomer concentrations (1.2-3.1-fold; p = 0.001) were measured with OSHA42 compared with the impinger. The IsoChek did not detect HDI monomer, and of the three samplers analyzed by laboratories other than UNC (i.e., OSHA42, IsoChek, and WA-DOSH), the WA-DOSH was in the best agreement with the impingers. The influence of clearcoat drying time on the sampler's ability to measure monomeric and polymeric HDI emphasizes the importance of the speciation of diisocyanates in chemical analysis and the careful consideration for the selection of the air sampler to be used when measuring exposures during

  12. Simultaneous decay of contact-angle and surface-tension during the rehydration of air-dried root mucilage

    NASA Astrophysics Data System (ADS)

    Arye, Gilboa; Chen, Fengxian

    2016-04-01

    Plants can extract or exude water and solutes at their root surface. Among the root exudates, the mucilage exhibits a surfactant like properties - depressing the surface-tension (ST, mN/m) at the water-air interface. The amphipathic nature of some of the mucilage molecules (e.g. lipids) is thought to be the reason for its surfactant like behavior. As the rhizosphere dries out, re-orientation and/or re-configuration of amphipathic molecules at the solid-air interface, may impart hydrophobic nature to the rhizosphere. Our current knowledge on the ST of natural and/or model root mucilage is based on measurements of the equilibrium ST. However, adsorption of amphipathic molecules at the water-air interface is not reached instantaneously. The hydrophobic nature of the rhizosphere was deduced from the initial advancing CA, commonly calculated from the first few milliseconds up to few seconds (depending on the method employed). We hypothesized that during the rehydration of the root mucilage; both quantities are dynamic. Processes such as water absorbance and dissolution, may vary the interfacial tensions as a function of time. Consequently, simultaneous reduction of both CA and ST as a function of time can be expected. The main objective of this study was to characterize and quantify the extent, persistency and dynamic of the CA and ST during rehydration of air-dried root mucilage. The study was involved with measurements of dynamic and equilibrium ST using the pedant drop or Wilhelmy plate method, respectively. Glass slides were coated with naturally occurring or model root mucilage and the CA of a sessile drop was measured optically, as a function of time. The results were analyzed based on the Young-Dupré and Young-Laplace equations, from which the simultaneous decay of CA and ST was deduced. The implication for the wettability and water flow in the rhizosphere will be discussed.

  13. An effective and economical method for the storage of plasma samples using a novel freeze-drying device.

    PubMed

    Wang, Lei; Xie, Mengmeng; Li, Ying; Zhang, Sen; Qiang, Wei; Cheng, Zeneng

    2016-09-28

    Biological samples, especially plasma samples, are conventionally stored under freezing conditions to maintain sample integrity prior to the detections of analytes. However, the storage of samples in a low-temperature environment is electric energy consuming, and the preparation of samples prior to analytes detection may be complicated. In this work, an effective and economical method was proposed to freeze-dry the samples using a novel device to allow subsequent storage of samples at ambient temperature. The sample preparations integrated in the new method are simple and easy to follow. Analytes were directly extracted with the extraction agent before sample injections. This new method was validated with quality control (QC) samples of levetiracetam and mycophenolic acid (MPA), and it was also applied to the pharmacokinetic (PK) studies of both drugs in healthy volunteers. When QC samples were stored and prepared with the new method, the detections of analytes were accurate and repeatable, and the analytes maintained stability for a long time. The PK studies of levetiracetam and MPA in healthy volunteers showed that the PK parameters of analytes stored with the new method were consistent with those stored with the conventional method. In conclusion, this effective and economical method is a practical option in reality and can play a big role in clinical and scientific drug researches. PMID:27619089

  14. Air quality assessment in the periurban area of Mexico Megacity during dry hot season in 2011 and 2012

    NASA Astrophysics Data System (ADS)

    Garcia-Reynoso, Agustin; Santos Garcia-Yee, Jose; Barrera-Huertas, Hugo; Gerardo Ruiz-Suárez, Luis

    2016-04-01

    Air quality is a human health threat not only in urbanized areas, it also affects the surrounding zones. Interaction between urban and rural areas can be evaluated by measurements and using models for regional areas that includes in its domain the peri-urban regions. The use of monitoring sites in remote areas is useful however it is not possible to cover all the region the use of models can provide valuable information about the source and fate of the pollution and its transformation. In order to evaluate the influence of the Mexico Megacity in the air quality of the region, two field campaigns were performed during the dry hot season during 2011 and 2012. Meterological and pollutant measurements were made during February and march 2011, in three sites towards the south east of Mexico Megacity, and from march to April 2012 towards the west after the Popocatepetl-Iztaccihuatl mountain range. Air quality modeling were performed by using the National Emissions Inventory 2008 during the studied periods, a comparison between measurements and the air quality model was performed. This type of studies can offer information about the pollutant distribution, the meteorological conditions and the exactness of emissions inventories. The latest can be useful for emissions inventory developers and policy makers.

  15. Utilizing Moist or Dry Swabs for the Sampling of Nasal MRSA Carriers? An In Vivo and In Vitro Study.

    PubMed

    Warnke, Philipp; Devide, Annette; Weise, Mirjam; Frickmann, Hagen; Schwarz, Norbert Georg; Schäffler, Holger; Ottl, Peter; Podbielski, Andreas

    2016-01-01

    This study investigates the quantitative bacterial recovery of Methicillin-resistant Staphylococcus aureus (MRSA) in nasal screenings by utilizing dry or moistened swabs within an in vivo and an in vitro experimental setting. 135 nasal MRSA carriers were each swabbed in one nostril with a dry and in the other one with a moistened rayon swab. Quantitative bacterial recovery was measured by standard viable count techniques. Furthermore, an anatomically correct artificial nose model was inoculated with a numerically defined suspension of MRSA and swabbed with dry and moistened rayon, polyurethane-foam and nylon-flocked swabs to test these different settings and swab-materials under identical laboratory conditions. In vivo, quantities of MRSA per nostril in carriers varied between <101 and >107 colony forming units, with a median of 2.15x104 CFU. However, no statistically significant differences could be detected for the recovery of MRSA quantities when swabbing nasal carriers with moist or dry rayon swabs. In vitro testing confirmed the in vivo data for swabs with rayon, polyurethane and nylon-flocked tips, since pre-moistening of swabs did not significantly affect the quantities of retrieved bacteria. Therefore, pre-moistening of swabs prior to nasal MRSA sampling provides no advantage in terms of recovering greater bacterial quantities and therefore can be omitted. In addition, this situation can be mimicked in an in vitro model, thereby providing a useful basis for future in vitro testings of new swab types or target organisms for screening approaches. PMID:27626801

  16. Ground-based air-sampling measurements near the Nevada Test Site after atmospheric nuclear tests.

    PubMed

    Cederwall, R T; Ricker, Y E; Cederwall, P L; Homan, D N; Anspaugh, L R

    1990-11-01

    Historical air-sampling data measured within 320 km (200 mi) of the Nevada Test Site (NTS) have been reviewed for periods following atmospheric nuclear tests, primarily in the 1950s. These data come mostly from high-volume air samplers, with some from cascade-impactor samplers. Measurements considered here are for beta radiation from gross fission products. The resulting air-quality data base is comprised of almost 13,000 samples from 42 sampling locations downwind of the NTS. In order to compile an accurate air-quality data base for use in estimating exposure via inhalation, raw data values were sought where possible, and the required calculations were performed on a computer with state-of-the-art algorithms. The data-processing procedures consisted of (1) entry and error checking of historical data; (2) determination of appropriate background values, air-sampling volumes, and net air concentrations; and (3) calculation of integrated air concentration (C) for each sample (considering fallout arrival times). Comparing C values for collocated high-volume and cascade-impactor samplers during the Upshot-Knothole series showed similar lognormal distributions, but with a geometric mean C for cascade impactors about half that for the high-volume air samplers. Overall, the uncertainty in C values is about a factor of three. In the past, it has been assumed that C could be related to ground deposition by a constant having units of velocity. In our data bases, simultaneous measurements of air concentration and ground deposition at the same locations were not related by a constant; indeed, there was a great amount of scatter. This suggests that the relationship between C and ground deposition in this situation is too complex to be treated adequately by simple approaches. PMID:2211113

  17. Ground-based air-sampling measurements near the Nevada Test Site after atmospheric nuclear tests

    SciTech Connect

    Cederwall, R.T.; Ricker, Y.E.; Cederwall, P.L.; Homan, D.N.; Anspaugh, L.R. )

    1990-11-01

    Historical air-sampling data measured within 320 km (200 mi) of the Nevada Test Site (NTS) have been reviewed for periods following atmospheric nuclear tests, primarily in the 1950s. These data come mostly from high-volume air samplers, with some from cascade-impactor samplers. Measurements considered here are for beta radiation from gross fission products. The resulting air-quality data base is comprised of almost 13,000 samples from 42 sampling locations downwind of the NTS. In order to compile an accurate air-quality data base for use in estimating exposure via inhalation, raw data values were sought where possible, and the required calculations were performed on a computer with state-of-the-art algorithms. The data-processing procedures consisted of (1) entry and error checking of historical data; (2) determination of appropriate background values, air-sampling volumes, and net air concentrations; and (3) calculation of integrated air concentration (C) for each sample (considering fallout arrival times). Comparing C values for collocated high-volume and cascade-impactor samplers during the Upshot-Knothole series showed similar lognormal distributions, but with a geometric mean C for cascade impactors about half that for the high-volume air samplers. Overall, the uncertainty in C values is about a factor of three. In the past, it has been assumed that C could be related to ground deposition by a constant having units of velocity. In our data bases, simultaneous measurements of air concentration and ground deposition at the same locations were not related by a constant; indeed, there was a great amount of scatter. This suggests that the relationship between C and ground deposition in this situation is too complex to be treated adequately by simple approaches.

  18. Thin Film XRF measurements (Wet and dry) of Black Sea Sediment Samples And Their Elemental Comparisons With Same Core U Channel Sample.

    NASA Astrophysics Data System (ADS)

    Acar, Dursun; Eris, Kadir; Sarı, Erol; Genc, S. Can

    2015-04-01

    This paper presents the XRF data from about 0.3mm thin film sediment core. We prepared 3 different model from same sediment core. The main aim is the finding for elemental changing of spectra variety and their comparison with physical changes of samples about mass and water content. Our XRF measurements were carried out by ITRAX (Cox System), and we have documented the some useful and more precision tricks; a) the first point is that the wet or dry nature of the core, b) the second is the use of U channel sample or thin film sample. For base referencing for the selected elements, we prepared normal wet U channel sample with the thickness of 1.5 cm. We used thin material (film) for keeping the humidty of every core sample's surface. Because humidity loss very high on thin film core sample and very effective to get bad results related to changing of topography and beam emission related to loss of pore water. Our XRF measurements have revealed that the Zn, Ti, Si, V,S, Cr, Mn, Ba, K and Ca elements were measured more precisely and accurate using by the dry thin film sample than those of wet U channel and wet thin sediment sample experiments. Beside this, Y, Zr, Nb, Rb, Sr, Ir, Fe,Co, Ni and Al elements were measured from the wet U channeled core more reliable with respect to the former. Lead (Pb) and Cd elements have behaved constantly during the three types of measurements. Keywords: Thin film XRF, U channel, Elements, Sediment, Measurement

  19. Air exposure induced characteristics of dry eye in conjunctival tissue culture.

    PubMed

    Lin, Hui; Qu, Yangluowa; Geng, Zhixin; Li, Cheng; Wu, Huping; Dong, Nuo; Liu, Zuguo; Li, Wei

    2014-01-01

    There are several animal models illustrating dry eye pathophysiology. Current study would like to establish an ex vivo tissue culture model for characterizing dry eye. Human conjunctival explants were cultured under airlift or submerged conditions for up to 2 weeks, and only airlifted conjunctival cultures underwent increased epithelial stratification. Starting on day 4, the suprabasal cells displayed decreased K19 expression whereas K10 keratin became evident in airlift group. Pax6 nuclear expression attenuated already at 2 days, while its perinuclear and cytoplasmic expression gradually increased. MUC5AC and MUC19 expression dramatically decreased whereas the full thickness MUC4 and MUC16 expression pattern disappeared soon after initiating the airlift condition. Real time PCR showed K16, K10 and MUC16 gene up-regulated while K19, MUC5AC, MUC19 and MUC4 down-regulated on day 8 and day 14. On day 2 was the appearance of apoptotic epithelial and stromal cells appeared. The Wnt signaling pathway was transiently activated from day 2 to day 10. The inflammatory mediators IL-1β, TNF-α, and MMP-9 were detected in the conditioned media after 6 to 8 days. In conclusion, airlifted conjunctival tissue cultures demonstrated Wnt signaling pathway activation, coupled with squamous metaplasia, mucin pattern alteration, apoptosis and upregulation of proinflammatory cytokine expression. These changes mimic the pathohistological alterations described in dry eye. This correspondence suggests that insight into the pathophysiology of dry eye may be aided through the use of airlifted conjunctival tissue cultures. PMID:24498087

  20. Ozone generation by negative direct current corona discharges in dry air fed coaxial wire-cylinder reactors

    SciTech Connect

    Yehia, Ashraf; Mizuno, Akira

    2013-05-14

    An analytical study was made in this paper for calculating the ozone generation by negative dc corona discharges. The corona discharges were formed in a coaxial wire-cylinder reactor. The reactor was fed by dry air flowing with constant rates at atmospheric pressure and room temperature, and stressed by a negative dc voltage. The current-voltage characteristics of the negative dc corona discharges formed inside the reactor were measured in parallel with concentration of the generated ozone under different operating conditions. An empirical equation was derived from the experimental results for calculating the ozone concentration generated inside the reactor. The results, that have been recalculated by using the derived equation, have agreed with the experimental results over the whole range of the investigated parameters, except in the saturation range for the ozone concentration. Therefore, the derived equation represents a suitable criterion for expecting the ozone concentration generated by negative dc corona discharges in dry air fed coaxial wire-cylinder reactors under any operating conditions in range of the investigated parameters.

  1. Atmospheric absorption model for dry air and water vapor at microwave frequencies below 100 GHz derived from spaceborne radiometer observations

    NASA Astrophysics Data System (ADS)

    Wentz, Frank J.; Meissner, Thomas

    2016-05-01

    The Liebe and Rosenkranz atmospheric absorption models for dry air and water vapor below 100 GHz are refined based on an analysis of antenna temperature (TA) measurements taken by the Global Precipitation Measurement Microwave Imager (GMI) in the frequency range 10.7 to 89.0 GHz. The GMI TA measurements are compared to the TA predicted by a radiative transfer model (RTM), which incorporates both the atmospheric absorption model and a model for the emission and reflection from a rough-ocean surface. The inputs for the RTM are the geophysical retrievals of wind speed, columnar water vapor, and columnar cloud liquid water obtained from the satellite radiometer WindSat. The Liebe and Rosenkranz absorption models are adjusted to achieve consistency with the RTM. The vapor continuum is decreased by 3% to 10%, depending on vapor. To accomplish this, the foreign-broadening part is increased by 10%, and the self-broadening part is decreased by about 40% at the higher frequencies. In addition, the strength of the water vapor line is increased by 1%, and the shape of the line at low frequencies is modified. The dry air absorption is increased, with the increase being a maximum of 20% at the 89 GHz, the highest frequency considered here. The nonresonant oxygen absorption is increased by about 6%. In addition to the RTM comparisons, our results are supported by a comparison between columnar water vapor retrievals from 12 satellite microwave radiometers and GPS-retrieved water vapor values.

  2. Biomonitoring of air pollution in a seasonally dry tropical suburban area using wheat transplants.

    PubMed

    Rajput, Madhu; Agrawal, Madhoolika

    2005-02-01

    Air pollution has been identified as a serious problem throughout the world which causes tremendous loss to the crops by affecting plant growth and yield. Earlier, air pollution was restricted to urban and industrial regions. Over the last few decades, however, it has become evident that pollutants can be transported over long distances and hence their impact may be felt widely over rural areas. The present study was conducted to evaluate the impact of urban air pollution on suburban agriculture with respect to the changes in photosynthetic rate, stomatal conductance, water-use efficiency, plant height, numbers of tillers, leaves, ears and seeds, chlorophyll, carotenoid, protein, phenol, ascorbic acid, nitrogen and sulphate-sulphur contents and seed weight of pot-grown wheat plants (Triticum aestivum var. HUW 468) kept at different sites around Varanasi city receiving varying levels of pollution load. Mean concentrations of SO2, NO2 and O3 were monitored. The study clearly showed that plants are negatively affected by the ambient levels of air pollutants. Reduction in various parameters directly corresponded with the air pollution levels at different sites. PMID:15736874

  3. Microbial counts and particulate matter levels in roadside air samples under skytrain stations, Bangkok, Thailand.

    PubMed

    Luksamijarulkul, Pipat; Kongtip, Pornpimol

    2010-05-01

    In conditions with heavy traffic and crowds of people on roadside areas under skytrain stations in Bangkok, the natural air ventilation may be insufficient and air quality may be poor. A study of 350 air samples collected from the roadside, under skytrain stations in Bangkok, was carried out to assess microbial counts (210 air samples) and particulate matter (PM10) levels (140 samples). The results reveal the mean +/- standard deviation bacterial counts and fungal counts were 406.8 +/- 302.7 cfu/m3 and 128.9 +/- 89.7 cfu/m3, respectively. The PM10 level was 186.1 +/- 188.1 microg/m3. When compared to recommended levels, 4.8% of air samples (10/210 samples) had bacterial counts more than recommended levels (> 1,000 cfu/ m3) and 27.1% (38/140 samples) had PM10 levels more than recommended levels (> 120 microg/m3). These may affect human health, especially of street venders who spend most of their working time in these areas. PMID:20578558

  4. Development of a multicopter-carried whole air sampling apparatus and its applications in environmental studies.

    PubMed

    Chang, Chih-Chung; Wang, Jia-Lin; Chang, Chih-Yuan; Liang, Mao-Chang; Lin, Ming-Ren

    2016-02-01

    To advance the capabilities of probing chemical composition aloft, we designed a lightweight remote-controlled whole air sampling component (WASC) and integrated it into a multicopter drone with agile maneuverability to perform aerial whole air sampling. A field mission hovering over an exhaust shaft of a roadway tunnel to collect air samples was performed to demonstrate the applicability of the multicopter-carried WASC apparatus. Ten aerial air samples surrounding the shaft vent were collected by the multicopter-carried WASC. Additional five samples were collected manually inside the shaft for comparison. These samples were then analyzed in the laboratory for the chemical composition of 109 volatile organic compounds (VOCs), CH4, CO, CO2, or CO2 isotopologues. Most of the VOCs in the upwind samples (the least affected by shaft exhaust) were low in concentrations (5.9 ppbv for total 109 VOCs), posting a strong contrast to those in the shaft exhaust (235.8 ppbv for total 109 VOCs). By comparing the aerial samples with the in-shaft samples for chemical compositions, the influence of the shaft exhaust on the surrounding natural air was estimated. Through the aerial measurements, three major advantages of the multicopter-carried WASC were demonstrated: 1. The highly maneuverable multicopter-carried WASC can be readily deployed for three-dimensional environmental studies at a local scale (0-1.5 km); 2. Aerial sampling with superior sample integrity and preservation conditions can now be performed with ease; and 3. Data with spatial resolution for a large array of gaseous species with high precision can be easily obtained. PMID:26386435

  5. Marine Technician's Handbook, Instructions for Taking Air Samples on Board Ship: Carbon Dioxide Project.

    ERIC Educational Resources Information Center

    Keeling, Charles D.

    This booklet is one of a series intended to provide explicit instructions for the collection of oceanographic data and samples at sea. The methods and procedures described have been used by the Scripps Institution of Oceanography and found reliable and up-to-date. Instructions are given for taking air samples on board ship to determine the…

  6. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Approved sampling devices; operation; air flowrate. 90.205 Section 90.205 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures §...

  7. DEVELOPMENT OF A SUB-SLAB AIR SAMPLING PROTOCOL TO SUPPORT ASSESSMENT OF VAPOR INTRUSION

    EPA Science Inventory

    The primary purpose of this research effort is to develop a methodology for sub-slab sampling to support the EPA guidance and vapor intrusion investigations after vapor intrusion has been established at a site. Methodologies for sub-slab air sampling are currently lacking in ref...

  8. Report on sampling and analysis of ambient air at the central waste complex

    SciTech Connect

    Stauffer, M., Fluor Daniel Hanford

    1997-02-13

    Over 160 ambient indoor air samples were collected from warehouses at the Central Waste Complex used for the storage of low- level radioactive and mixed wastes. These grab (SUMMA) samples were analyzed by gas chromatography-mass spectrometry using a modified EPA TO-14 procedure. The data from this survey suggest that several buildings had elevated concentrations of volatile organic compounds.

  9. EVALUATION OF THE FILTER PACK FOR LONG-DURATION SAMPLING OF AMBIENT AIR

    EPA Science Inventory

    A 14-week filter pack (FP) sampler evaluation field study was conducted at a site near Bondville, IL to investigate the impact of weekly sampling duration. Simultaneous samples were collected using collocated filter packs (FP) from two independent air quality monitoring networks...

  10. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks.

    PubMed

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL(- 1) with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  11. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks☆

    PubMed Central

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-01-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL− 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  12. A Cryosampler Payload for Aseptic Air Sample Collection at Stratospheric Altitudes Using Balloons.

    NASA Astrophysics Data System (ADS)

    Sreenivasan, S.; Dutt, C. B. S.; Bhargava, P.; Shivaji, S.; Manchanda, R. K.

    A balloon borne Astrobiology program is being conducted from the National Balloon Facility of the Tata Institute of Fundamental Research at Hyderabad India in which a liquid Neon cooled cryo pump collects air samples under sterile conditions in the altitude regime 19 - 41 Km Pursuant to the encouraging results obtained from an earlier experiment conducted on January 2001 a new payload was configured and the balloon flight was conducted on April 20 2005 after implementing much more rigorous and enhanced sterilization protocol to completely rule out contamination from ground Air samples were collected in the altitude region 20 - 41 Km and are under analysis in the National laboratories in India for detecting the presence of living microbial cells In this paper we discuss the design and fabrication of the air sample collection probes the stringent sterilization protocol evolved for ensuring that the probes are aseptic before the commencement of the experiment and the sample retrival methods for analysis in the laboratory

  13. Modelling of heat and mass transfer in a granular medium during high-temperature air drying. Effect of the internal gas pressure

    NASA Astrophysics Data System (ADS)

    Othmani, Hammouda; Hassini, Lamine; Lamloumi, Raja; El Cafsi, Mohamed Afif

    2016-02-01

    A comprehensive internal heat and water transfer model including the gas pressure effect has been proposed in order to improve the industrial high-temperature air drying of inserts made of agglomerated sand. In this model, the internal gas phase pressure effect was made perfectly explicit, by considering the liquid and vapour transfer by filtration and the liquid expulsion at the surface. Wet sand enclosed in a tight cylindrical glass bottle dried convectively at a high temperature was chosen as an application case. The model was validated on the basis of the experimental average water content and core temperature curves for drying trials at different operating conditions. The simulations of the spatio-temporal distribution of internal gas pressure were performed and interpreted in terms of product potential damage. Based on a compromise between the drying time and the pressure increase, a simple drying cycle was implemented in order to optimize the drying process.

  14. Survey of volatile organic compounds found in indoor and outdoor air samples from Japan.

    PubMed

    Tanaka-Kagawa, Toshiko; Uchiyama, Shigehisa; Matsushima, Erika; Sasaki, Akira; Kobayashi, Hiroshi; Kobayashi, Hiromi; Yagi, Masahiro; Tsuno, Masahiko; Arao, Masa; Ikemoto, Kazumi; Yamasaki, Makoto; Nakashima, Ayako; Shimizu, Yuri; Otsubo, Yasufumi; Ando, Masanori; Jinno, Hideto; Tokunaga, Hiroshi

    2005-01-01

    Indoor air quality is currently a growing concern, mainly due to the incidence of sick building syndrome and building related illness. To better understand indoor air quality in Japan, both indoor and outdoor air samples were collected from 50 residences in Iwate, Yamanashi, Shiga, Hyogo, Kochi and Fukuoka Prefectures. More than 100 volatile organic compounds (VOCs) were analyzed by thermal desorption-gas chromatography/mass spectrometry method. The most abundant class of compounds present in the indoor air samples were identified (i.e. alkanes, alkylbenzenes and terpenes). For 30% of the indoor air samples, the sum of each VOC exceeded the current provisional guideline value for total VOC (TVOC, 400 microg/m3). The major component of these samples included linear and branched-chain alkanes (possibly derived from fossil fuels), 1,4-dichlorobenzene (a moth repellent), alpha-pinene (emission from woody building materials) and limonene (probably derived from aroma products). As an unexpected result, one residence was polluted with an extremely high concentration of 1,1,1,2-tetrafluoroethane (720 microg/m3), suggesting accidental leakage from a household appliance such as a refrigerator. The results presented in this paper are important in establishing the Japanese target compound list for TVOC analysis, as well as defining the current status of indoor air quality in Japan. PMID:16541748

  15. Dry eye syndrome

    MedlinePlus

    ... of dry eyes include: Dry environment or workplace (wind, air conditioning) Sun exposure Smoking or second-hand ... NOT smoke and avoid second-hand smoke, direct wind, and air conditioning. Use a humidifier, especially in ...

  16. Laboratory validation and field verification of a new passive colorimetric air monitoring badge for sampling hydrogen sulfide in air.

    PubMed

    Kring, E V; Damrell, D J; Henry, T J; DeMoor, H M; Basilio, A N; Simon, C E

    1984-01-01

    The Pro-Tek passive colorimetric air monitoring badge for personal or area sampling of hydrogen sulfide is described. The badge has been validated over the range of 1.8 to 164 ppm-hours (0.23-21 ppm on an 8-hour TWA basis). It has an overall accuracy throughout this range of +/- 15.9% and meets the NIOSH accuracy criteria for an analytical and sampling method. The colorimetric analytical method used is based on the Texas Air Control Board's Molybdenum Blue method. Color-activated exposed badge solutions are read out on a standard laboratory spectrophotometer using 1 centimeter (10 mm) cells. Variations in exposure temperature (between 10 degrees and 40 degrees C), relative humidity, and face velocity (between 2 and 250 ft/min) do not affect badge performance. Unexposed badges are stable for more than 12 months refrigerated and for two months at room temperature. PMID:6702591

  17. SAMPLING AND ANALYSIS OF PCDDS AND PCDFS IN STATIONARY SOURCE EMISSION AIR SAMPLES

    EPA Science Inventory

    Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzo-furans (PCDFs) are two classes of extremely toxic compounds produced and emitted into the environment as a result of combustion processes. lthough no standard method for sampling or analysis of PCDDs and PCDFs ...

  18. Determination of radiocarbon in stratospheric CO2, obtained through AirCore sampling.

    NASA Astrophysics Data System (ADS)

    Paul, Dipayan; Chen, Huilin; Been, Henk A.; Kivi, Rigel; Meijer, Harro A. J.

    2016-04-01

    The concentration of Greenhouse Gases (GHG), with carbon dioxide as the most prominent example, has been and still is increasing, predominantly due to emissions from fossil fuel combustion. CO2 is also the most important component of the global carbon cycle. Among other tracers, radiocarbon (Carbon-14) is a unique and an important atmospheric tracer used in the understanding of the global carbon cycle. Radiocarbon is a naturally occurring isotope (radioactive, t 1/2 = 5730 ± 40 years) of carbon produced through the interaction of thermalized neutrons and nitrogen in the upper atmosphere. Generally, for performing atmospheric radiocarbon measurements in the higher atmosphere, large samples (few liters of air) were collected using aircrafts and balloons. However, collecting stratospheric samples on a regular basis for radiocarbon analysis is extremely expensive. Here we describe the determination of radiocarbon concentrations in stratospheric CO2, collected using AirCore sampling. AirCore is an innovative sampling technique for obtaining vertical atmospheric profiles and, in Europe, is done on a regular basis at Sodankylä, Finland for CO2, CH4 and CO. The stratospheric parts of two such AirCore profiles were used in this study as a proof-of-principle. CO2 from the stratospheric air samples were extracted and converted to elemental carbon, which were then measured at the Accelerator Mass Spectrometric (AMS) facility of the Centre for Isotope Research (CIO) at the University of Groningen. The stratospheric part of the AirCore profile was divided into six sections, each contained approximately 10 μg C. A detailed description of the extraction, graphitization, AMS analysis and the derivation of the stratospheric radiocarbon profile will be the main focus. Through our results, we will show that AirCore is a viable sampling method for performing high-precision radiocarbon measurements of stratospheric CO2 with reasonably good spatial resolution on a regular basis

  19. Comparison of mold concentrations quantified by MSQPCR in indoor and outdoor air sampled simultaneously

    SciTech Connect

    Meklin, Teija; Reponen, Tina; McKinstry, Craig A.; Cho, Seung H.; Grinshpun, Sergey A.; Nevalainen, Aino; Vepsalainen, Asko; Haugland, Richard A.; Lemasters, Grace; Vesper, Sephen J.

    2007-08-15

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of 36 mold species in dust and in indoor and in outdoor air samples that were taken simultaneously in 17 homes in Cincinnati with no-known water damage. The total spore concentrations in the indoor (I) and outdoor (O) air samples were statistically significantly different and the concentrations in the three sample types of many of the individual species were significantly different (p < 0.05 based on the Wilcoxon Signed Rank Test). The I/O ratios of the averages or geometric means of the individual species were generally less than 1; but these I/O ratios were quite variable ranging from 0.03 for A. sydowii to 1.2 for Acremonium strictum. There were no significant correlations for the 36 specific mold concentrations between the dust samples and the indoor or outdoor air samples (based on the Spearman’s Rho test). The indoor and outdoor air concentrations of 32 of the species were not correlated. Only Aspergillus penicillioides, C. cladosporioides types 1 and 2 and C. herbarum had sufficient data to estimate a correlation at rho > 0.5 with signicance (p < 0.05) In six of these homes, a previous dust sample had been collected and analyzed 2 years earlier. The ERMI© values for the dust samples taken in the same home two years apart were not significantly different (p=0.22) based on Wilcoxon Signed Rank Test.

  20. Pesticide detection in air samples from contrasted houses and in their inhabitants' hair.

    PubMed

    Raeppel, Caroline; Salquèbre, Guillaume; Millet, Maurice; Appenzeller, Brice M R

    2016-02-15

    In order to identify associations between indoor air contamination and human exposure to pesticides, hair samples from 14 persons (9 adults and 5 children below 12 years) were collected simultaneously with the air of their 5 contrasted houses. Three houses were situated in Alsace (France), one in Lorraine (France) and one in Luxembourg (Luxembourg). Houses were located in urban (n=3), semi-urban (n=1) and rural areas (n=1). Twenty five (25) pesticides were detected at least once in indoor air samples and 20 pesticides were detected at least once in hair samples. The comparison between hair and air samples for the same sampling periods shows that pesticides detected in the two matrices were not necessarily associated. Exposure profiles varied from one home to another but also between inhabitants of the same home, suggesting that exposure can be different between inhabitants of the same home. This study demonstrated the usefulness and the complementarity of hair analysis, for the personalized biomonitoring of people exposure to pesticides, and air analysis, for the identification of airborne exposure and house contamination. PMID:26706757

  1. Field evaluation of sampling and analysis for organic pollutants in indoor air

    SciTech Connect

    Chuang, J.C.; Mack, G.A.; Stockrahm, J.W.; Hannan, S.W.; Bridges, C.

    1988-08-01

    The objectives of the study were to determine the feasibility of the use of newly developed indoor air samplers in residential indoor air sampling and to evaluate methodology for characterization of the concentrations of polynuclear aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in residential air. Residential air sampling was conducted in Columbus, Ohio during the winter of 1986/87. The PAH derivatives were found at much lower levels than their parent PAH. Higher average indoor levels of all but three target compounds were found compared to outdoor levels. The higher outdoor levels of these three compounds (naphthalene dicarboxylic acid anhydride, pyrene dicarboxylic acid anhydride, and 2-nitrofluoranthene) are probably due to atmospheric transformation. Cigarette smoking was identified as the most-significant contributor to indoor levels of PAH and PAH derivatives. Homes with gas-heating systems appeared to have higher pollutant levels compared to homes with electric-heating systems.

  2. Comparison of sampling methods for radiocarbon dating of carbonyls in air samples via accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    Schindler, Matthias; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander

    2016-05-01

    Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO2 and reduced to graphite to determine 14C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).

  3. Substantiation of 25 kGy radiation sterilization dose for banked air dried amniotic membrane and evaluation of personnel skill in influencing finished product bioburden.

    PubMed

    Marsit, Nagi; Dwejen, Samira; Saad, Ibrahim; Abdalla, Sedigh; Shaab, Arej; Salem, Salma; Khanfas, Enas; Hasan, Anas; Mansur, Mohamed; Abdul Sammad, Mohamed

    2014-12-01

    Preparation of amniotic membrane (AM) by air drying method followed by radiation sterilization is simple and valuable approach; sterility and quality of the final AM product are depending on the quality management system at the tissue bank. Validation and substantiation of radiation sterilization dose (RSD) for tissue allografts is an essential step for the development and validation of the standard operating procedures (SOP). Application of SOP is perfectly relying on trained staff. Skills differences among personnel involved in AM preparation could have an effect on microbiological quality of the finished product and subsequently on the RSD required. AM were processed by four different couples of the tissue bank technicians. The AM grafts were randomly selected and subjected to bioburden test to validate and substantiate the 25 kGy RSD. Bioburden test for AM grafts were also useful to evaluate the skill of the tissue bank technicians and thus, to validate the current SOP for air dried AM. Moreover, the effect of placental source on bioburden counts on AM grafts was assessed. Substantiation of the 25 kGy RSD at a sterility assurance level of 10(-1), and sample item portion = 1, was carried out using Method VD max (25) of the International Organization for Standardization, document no. 11137-2 (ISO in Sterilization of healthcare products-radiation-part 2: establishing the sterilization dose, Method VDmax-substantiation of 25 kGy or 15 kGy as the sterilization dose, International Standard Organization, 2006). The results showed that there were no significant differences in the bioburdens of the four batches (α = 1 %), this means no significant differences in the skill of the four couples of the tissue bank technicians in terms of their ability to process AM according to the air dried AM SOP. The 25 kGy RSD was validated and substantiated as a valid sterilization dose for the AM prepared with the current established SOP at the Biotechnology Research Center

  4. Accelerator Mass Spectrometric determination of radiocarbon in stratospheric CO2, retrieved from AirCore sampling.

    NASA Astrophysics Data System (ADS)

    Paul, Dipayan; Been, Henk A.; Chen, Huilin; Kivi, Rigel; Meijer, Harro A. J.

    2015-04-01

    In this decade, understanding the impact of human activities on climate is one of the key issues of discussion globally. The continuous rise in the concentration of greenhouse gases, e.g., CO2, CH4, etc. in the atmosphere, predominantly due to human activities, is alarming and requires continuous monitoring to understand the dynamics. Radiocarbon is an important atmospheric tracer and one of the many used in the understanding of the global carbon budget, which includes the greenhouse gases like CO2 and CH4. Measurement of 14C (or radiocarbon) in atmospheric CO2 generally requires collection of large air samples (few liters) from which CO2 is extracted and then the concentration of radiocarbon is determined. Currently, Accelerator Mass Spectrometry (AMS) is the most precise, reliable and widely used technique for atmospheric radiocarbon detection. However, the regular collection of air samples from troposphere and stratosphere, for example using aircraft, is prohibitively expensive. AirCore is an innovative atmospheric sampling system, developed by NOAA. It comprises of a long tube descending from a high altitude with one end open and the other closed, and has been demonstrated to be a reliable, cost-effective sampling system for high-altitude profile (up to ~ 30 km) measurements of CH4and CO2(Karion et al. 2010). In Europe, AirCore measurements are being performed on a regular basis near Sodankylä since September 2013. Here we describe the analysis of two such AirCore samples collected in July 2014, Finland, for determining the 14C concentration in stratospheric CO2. The two AirCore samples were collected on consecutive days. Each stratospheric AirCore sample was divided into six fractions, each containing ~ 35 μg CO2 (~9.5 μg C). Each fraction was separately trapped in 1 /4 inch coiled stainless steel tubing for radiocarbon measurements. The procedure for CO2 extraction from the stratospheric air samples; the sample preparation, with samples containing < 10

  5. Effect of inhaled budesonide on bronchial reactivity to histamine, exercise, and eucapnic dry air hyperventilation in patients with asthma.

    PubMed Central

    Vathenen, A S; Knox, A J; Wisniewski, A; Tattersfield, A E

    1991-01-01

    BACKGROUND: It has been suggested that inhaled corticosteroids may provide greater protection against constrictor stimuli that act indirectly such as exercise than those that act directly such as histamine. METHODS: The effects of six weeks treatment with inhaled budesonide (800 micrograms twice daily) on bronchial reactivity to histamine, exercise, and eucapnic voluntary hyperventilation of dry air were compared in a double blind, placebo controlled, non-crossover study in 40 subjects with asthma. Change in bronchial reactivity to histamine and eucapnic hyperventilation over the six weeks was measured as change in the provocative dose of histamine or dry air causing a 20% fall in FEV1 (PD20 histamine and PV20 eucapnic hyperventilation (EVH) of dry air); this was not possible for exercise because of the development of refractoriness. To enable the change in response to all three stimuli to be compared, the response (percent fall in FEV1) to a fixed dose was measured for all three challenge tests. RESULTS: After budesonide there was an increase in PD20 histamine from 0.48 to 2.81 mumol and in PV20 EVH from 364 to 639 litres, and a significant correlation between the changes in PD20 histamine and PV20 EVH (r = 0.63). The median percentage fall in FEV1 in response to eucapnic hyperventilation, exercise, and histamine was similar before budesonide (25.5%, 26.6%, and 24.5%); the reduction in the percentage fall in FEV1 with budesonide was also similar for the three challenges (18.9%, 17.5%, and 16.6%), and all differed significantly from the changes following placebo. There was a significant correlation between change in percentage fall in FEV1 after budesonide with the three stimuli (histamine v exercise: r = 0.48; histamine v eucapnic hyperventilation: r = 0.46; exercise v eucapnic hyperventilation: r = 0.63). CONCLUSION: The similar magnitude of change in bronchial reactivity to all three stimuli after budesonide and the within subject correlation obtained between

  6. Oxidation resistance of selected mechanical carbons at 650 deg C in dry flowing air

    NASA Technical Reports Server (NTRS)

    Allen, G. P.; Wisander, D. W.

    1973-01-01

    Oxidation experiments were conducted with several experimental mechanical carbons at 650 C in air flowing at 28 cu cm/sec (STP). Experiments indicate that boron carbide addition and zinc phosphate treatment definitely improved oxidation resistance. Impregnation with coal tar pitch before final graphitization had some beneficial effect on oxidation resistance and it markedly improved flexure strength and hardness. Graphitization temperature alone did not affect oxidation resistance, but with enough added boron carbide the oxidation resistance was increased although the hardness greatly decreased.

  7. Using dried blood spot sampling to improve data quality and reduce animal use in mouse pharmacokinetic studies.

    PubMed

    Wickremsinhe, Enaksha R; Perkins, Everett J

    2015-03-01

    Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 μL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal-often to a single collection per mouse-thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 μL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study. PMID:25836959

  8. Using Dried Blood Spot Sampling to Improve Data Quality and Reduce Animal Use in Mouse Pharmacokinetic Studies

    PubMed Central

    Wickremsinhe, Enaksha R; Perkins, Everett J

    2015-01-01

    Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 µL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal—often to a single collection per mouse—thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 µL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study. PMID:25836959

  9. Cross contamination of lead and cadmium during dry ashing of food samples.

    PubMed

    Fecher, Peter; Ruhnke, Gisela

    2002-04-01

    Common white sugar was ashed in a muffle furnace under controlled heating at 450 degrees C. Together with these samples, sugar with added amounts of Pb and Cd (20, 50 micro g) was mineralized in the same furnace. Depending on the absolute amount of Pb and Cd present in the furnace, an increase in the 'blank' values of the unspiked sugar samples was found. The same effect was observed when reference material containing natural amounts of Pb and Cd (TORT-1, Lobster) was present in the furnace. Although the results strongly depend on the blank levels of the muffle furnace, cross contamination effects could be demonstrated for both elements. The investigations demonstrate, that at a temperature of 450 degrees C, both Cd and Pb are lost during ashing of samples. The type of matrix in a sample with high contents of Pb and Cd has no significant effect on the volatility of these elements. The vapor lost from a sample containing high amounts of Pb and Cd will falsify the concentration in low level samples present in the furnace. PMID:12194040

  10. A sample holder for measuring the magnetic properties of air-sensitive compounds

    NASA Astrophysics Data System (ADS)

    Berlie, Adam; Terry, Ian; Szablewski, Marek

    2011-01-01

    A sample holder is reported which has allowed the magnetic characterization of air-sensitive compounds to be made in a Quantum Design Magnetic Properties Measurement System as a function of the applied field (0-5 T), and at temperatures ranging from 2 to 290 K. The sample holder is in the form of a specially designed tube, which is made from high purity quartz, utilizes PTFE (polytetrafluoroethylene) plugs and is reusable. This construction also offers the benefit that no heat treatment of the holder is required during sample loading, making the sample holder suitable for thermally sensitive compounds. The application of this sample holder is demonstrated for the case of Ni(cod)2 (cod = 1,5-cyclooctadiene), a compound that decomposes when exposed to air and/or heat. This material's instability has, so far, prevented the magnetic characterization of the compound, with nickel nanoparticles, a product of the decomposition, usually being measured instead.

  11. Physiological and Biochemical Responses of Yarrowia lipolytica to Dehydration Induced by Air-Drying and Freezing

    PubMed Central

    Pénicaud, Caroline; Landaud, Sophie; Jamme, Frédéric; Talbot, Pauline; Bouix, Marielle; Ghorbal, Sarrah; Fonseca, Fernanda

    2014-01-01

    Organisms that can withstand anhydrobiosis possess the unique ability to temporarily and reversibly suspend their metabolism for the periods when they live in a dehydrated state. However, the mechanisms underlying the cell’s ability to tolerate dehydration are far from being fully understood. The objective of this study was to highlight, for the first time, the cellular damage to Yarrowia lipolytica as a result of dehydration induced by drying/rehydration and freezing/thawing. Cellular response was evaluated through cell cultivability determined by plate counts, esterase activity and membrane integrity assessed by flow cytometry, and the biochemical composition of cells as determined by FT-IR spectroscopy. The effects of the harvesting time (in the log or stationary phase) and of the addition of a protective molecule, trehalose, were investigated. All freshly harvested cells exhibited esterase activity and no alteration of membrane integrity. Cells freshly harvested in the stationary phase presented spectral contributions suggesting lower nucleic acid content and thicker cell walls, as well as longer lipid chains than cells harvested in the log phase. Moreover, it was found that drying/rehydration induced cell plasma membrane permeabilization, loss of esterase activity with concomitant protein denaturation, wall damage and oxidation of nucleic acids. Plasma membrane permeabilization and loss of esterase activity could be reduced by harvesting in the stationary phase and/or with trehalose addition. Protein denaturation and wall damage could be reduced by harvesting in the stationary phase. In addition, it was shown that measurements of loss of membrane integrity and preservation of esterase activity were suitable indicators of loss and preservation of cultivability, respectively. Conversely, no clear effect of freezing/thawing could be observed, probably because of the favorable operating conditions applied. These results give insights into Y. lipolytica

  12. Problems Found Using a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2008-04-01

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion of anthropogenic activity estimates with the relative bias being small compared to the dispersion, indicating that the system would not give false positive indications for an appropriately set decision level. By also measuring environmental air sample filters simultaneously with electroplated alpha filters, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations from calibrated values indicating that the system would give false negative indications. Use of the current algorithm is, therefore, not recommended for general assay applications. Use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve-fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha activities on air sample filters (not due to radon progeny) around the 200 disintegrations per minute level.

  13. Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2009-01-23

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level.

  14. Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)

    NASA Technical Reports Server (NTRS)

    Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.

    1974-01-01

    The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.

  15. Three years of greenhouse gas column-averaged dry air mole fractions retrieved from satellite - Part 2: Methane

    NASA Astrophysics Data System (ADS)

    Schneising, O.; Buchwitz, M.; Burrows, J. P.; Bovensmann, H.; Bergamaschi, P.; Peters, W.

    2009-01-01

    Carbon dioxide (CO2) and methane (CH4) are the two most important anthropogenic greenhouse gases. SCIAMACHY on ENVISAT is the first satellite instrument whose measurements are sensitive to concentration changes of the two gases at all altitude levels down to the Earth's surface where the source/sink signals are largest. We have processed three years (2003-2005) of SCIAMACHY near-infrared nadir measurements to simultaneously retrieve vertical columns of CO2 (from the 1.58 μm absorption band), CH4 (1.66 μm) and oxygen (O2 A-band at 0.76 μm) using the scientific retrieval algorithm WFM-DOAS. We show that the latest version of WFM-DOAS, version 1.0, which is used for this study, has been significantly improved with respect to its accuracy compared to the previous versions while essentially maintaining its high processing speed (~1 min per orbit, corresponding to ~6000 single measurements, and per gas on a standard PC). The greenhouse gas columns are converted to dry air column-averaged mole fractions, denoted XCO2 (in ppm) and XCH4 (in ppb), by dividing the greenhouse gas columns by simultaneously retrieved dry air columns. For XCO2 dry air columns are obtained from the retrieved O2 columns. For XCH4 dry air columns are obtained from the retrieved CO2 columns because of better cancellation of light path related errors compared to using O2 columns retrieved from the spectrally distant O2 A-band. Here we focus on a discussion of the XCH4 data set. The XCO2 data set is discussed in a separate paper (Part 1). For 2003 we present detailed comparisons with the TM5 model which has been optimally matched to highly accurate but sparse methane surface observations. After accounting for a systematic low bias of ~2% agreement with TM5 is typically within 1-2%. We investigated to what extent the SCIAMACHY XCH4 is influenced by the variability of atmospheric CO2 using global CO2 fields from NOAA's CO2 assimilation system CarbonTracker. We show that the CO2 corrected and

  16. Molecular Diagnosis and Identification of Leishmania Species in Jordan from Saved Dry Samples

    PubMed Central

    Hijjawi, Nawal; Kanani, Kalil A.; Rasheed, Malak; Atoum, Manar; Abdel-Dayem, Mona; Irhimeh, Mohammad R.

    2016-01-01

    Diagnosis of the endemic cutaneous leishmaniasis (CL) in Jordan relies on patient clinical presentation and microscopic identification. Studies toward improved identification of the causative Leishmania species, especially in regions where multiple species exist, and the introduction of these techniques into medical diagnosis is paramount. This study looked at the current epidemiology of CL in Jordan. Clinically diagnosed 41 patients with CL were tested for the presence of Leishmania parasite using both Giemsa staining from skin scraps on glass slides and ITS1-PCR from samples blotted onto storage cards (NucleoCards®). Microscopically, 28 out of the 41 (68.3%) collected samples were positive for amastigotes, whereas the molecular ITS1-PCR amplification successfully identified 30 of the 41 samples (73.2%). Furthermore, PCR-RFLP analysis allowed species identification which is impossible microscopically. Of the 30 PCR positive samples, 28 were Leishmania major positive and the other two samples were Leishmania tropica. This indicates that L. major is the most prevalent species in Jordan and the two L. tropica cases originated from Syria indicating possible future L. tropica outbreaks. Diagnosis of CL based on clinical presentation only may falsely increase its prevalence. Although PCR is more sensitive, it is still not available in our medical laboratories in Jordan. PMID:27403435

  17. Heterogeneous photochemical reactions of a propylene-nitrogen dioxide-metal oxide-dry air system

    NASA Astrophysics Data System (ADS)

    Takeuchi, Koji; Ibusuki, Takashi

    Photochemical reactions of a C 3H 6-NO 2-air system in the presence of metal oxide were investigated. The metal oxides showing strong photooxidation activity were found to be n-type semiconductor oxides with the energy band gap around 3 eV. Formation of cyano-compounds (HCN and CH 3CN) was also observed and the activity can be explained in terms of the adsorptivity of NO onto metal oxides. Coalfired fly ash as a model of mixed metal oxides was also examined and their photocatalytic action was discussed.

  18. Atmospheric dry deposition in the vicinity of the Salton Sea, California - I: Air pollution and deposition in a desert environment

    USGS Publications Warehouse

    Alonso, R.; Bytnerowicz, A.; Boarman, W.I.

    2005-01-01

    Air pollutant concentrations and atmospheric dry deposition were monitored seasonally at the Salton Sea, southern California. Measurements of ozone (O 3), nitric acid vapor (HNO3), ammonia (NH3), nitric oxide (NO), nitrogen dioxide (NO2) and sulfur dioxide (SO 2) were performed using passive samplers. Deposition rates of NO 3-, NH4+, Cl-, SO 42-, Na+, K+ and Ca2+ to creosote bush branches and nylon filters as surrogate surfaces were determined for one-week long exposure periods. Maximum O3 values were recorded in spring with 24-h average values of 108.8 ??g m-3. Concentrations of NO and NO2 were low and within ranges of the non-urban areas in California (0.4-5.6 and 3.3-16.2 ??g m-3 ranges, respectively). Concentrations of HNO3 (2.0-6.7 ??g m-3) and NH 3 (6.4-15.7 ??g m-3) were elevated and above the levels typical for remote locations in California. Deposition rates of Cl-, SO42-, Na+, K+ and Ca2+ were related to the influence of sea spray or to suspended soil particles, and no strong enrichments caused by ions originated by human activities were detected. Dry deposition rates of NO3- and NH4+ were similar to values registered in areas where symptoms of nitrogen saturation and changes in species composition have been described. Deposition of nitrogenous compounds might be contributing to eutrophication processes at the Salton Sea. ?? 2005 Elsevier Ltd. All rights reserved.

  19. Seed germination from lowland tapir (Tapirus terrestris) fecal samples collected during the dry season in the Northern Brazilian Amazon.

    PubMed

    Barcelos, Adriana Renata; Bobrowiec, Paulo Estefano D; Sanaiotti, Tânia Margarete; Gribel, Rogério

    2013-03-01

    This study evaluated the potential of lowland tapirs as seed dispersers in the northern Brazilian Amazon. The study analyzed the viability of seeds after passage through the gut. Fecal samples were collected from 6 different vegetation physiognomies in Viruá National Park during the dry season. The samples were then kept in a greenhouse for 16 months to allow the seeds to germinate. The seedling species were identified and classified according to the type of fruit, plant habit, seed size and type of ingestion. Of the 111 fecal samples, 94 (84.7%) had viable seeds of 75 species. Melastomataceae was the most frequent family with viable seeds in the fecal samples (69.1% of samples, N= 18 species). The data suggest that the importance of the lowland tapirs as dispersers is not restricted to the species consumed actively by frugivory but also extends to species accidentally consumed during browsing. The occurrence of both large and small viable seeds in the fecal samples as well as a number of large drupes, which probably cannot be transported via endozoochory by any other animal species, provide evidence of the ecological importance of lowland tapirs to the dynamics of the forest-campinarana vegetation mosaic in the region. PMID:23586561

  20. Passive dosimeters for nitrogen dioxide in personal/indoor air sampling: A review

    PubMed Central

    Yu, Chang Ho; Morandi, Maria T.; Weisel, Clifford P.

    2015-01-01

    Accurate measurement of nitrogen dioxide concentrations in both outdoor and indoor environments, including personal exposures, is a fundamental step for linking atmospheric nitrogen dioxide levels to potential health and ecological effects. The measurement has been conducted generally in two ways: active (pumped) sampling and passive (diffusive) sampling. Diffusion samplers, initially developed and used for workplace air monitoring, have been found to be useful and cost-effective alternatives to conventional pumped samplers for monitoring ambient, indoor and personal exposures at the lower concentrations found in environmental settings. Since the 1970s, passive samplers have been deployed for ambient air monitoring in urban and rural sites, and to determine personal and indoor exposure to NO2. This article reviews the development of NO2 passive samplers, the sampling characteristics of passive samplers currently available, and their application in ambient and indoor air monitoring and personal exposure studies. The limitations and advantages of the various passive sampler geometries (i.e., tube, badge, and radial type) are also discussed. This review provides researchers and risk assessors with practical information about NO2 passive samplers, especially useful when designing field sampling strategies for exposure and indoor/outdoor air sampling. PMID:18446185

  1. Effect of hot air drying on volatile compounds of Flammulina velutipes detected by HS-SPME-GC-MS and electronic nose.

    PubMed

    Yang, Wenjian; Yu, Jie; Pei, Fei; Mariga, Alfred Mugambi; Ma, Ning; Fang, Yong; Hu, Qiuhui

    2016-04-01

    Volatile compounds are important factors that affect the flavor quality of Flammulina velutipes, but the changes occurring during hot air drying is still unclear. To clarify the dynamic changes of flavor components during hot air drying, comprehensive flavor characterization and volatile compounds of F. velutipes were evaluated using electronic nose technology and headspace solid phase micro-extraction combined with gas chromatography-mass spectrometry (HS-SPME-GC-MS), respectively. Results showed that volatile components in F. velutipes significantly changed during hot air drying according to the principal component analysis and radar fingerprint chart of electronic nose. Volatile compounds of fresh F. velutipes consisted mainly of ketones, aldehydes and alcohols, and 3-octanone was the dominant compound. Drying process could significantly decrease the relative content of ketones and promoted the generation of alcohols, acids, and esters, which became the main volatile compounds of dried F. velutipes. These may provide a theoretical basis for the formation mechanism of flavor substances in dried F. velutipes. PMID:26593566

  2. Solubility testing of actinides on breathing-zone and area air samples

    SciTech Connect

    Metzger, R.L.; Jessop, B.H.; McDowell, B.L.

    1996-02-01

    A solubility testing method for several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALS{reg_sign}) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of U{sub 3}O{sub 8}. Profiles developed for U{sub 3}O{sub 8} samples show good agreement with in vitro and in vivo tests performed by other investigators on samples from the same uranium mills.

  3. A Numerical Study of the Impacts of Dry Air on Tropical Cyclone Formation: A Development Case and a Non-development Case

    NASA Astrophysics Data System (ADS)

    Fritz, C.; Wang, Z.

    2012-12-01

    The impacts of dry air on tropical cyclone formation are examined in the numerical model simulations of ex-Gaston (2010) and pre-Fay (2008). The former, a remnant low downgraded from a short-lived tropical cyclone, can be regarded as a non-developing system as it failed to redevelop, and the latter developed into a tropical cyclone despite lateral dry air entrainment and a transient upper-level dry air intrusion. Water vapor budget analysis suggests that the mean vertical moisture transport plays the dominant role in moistening the free atmosphere. Backward trajectory analysis and water budget analysis show that vertical transport of dry air from the middle and upper troposphere, where a well-defined wave pouch is absent, contributes to the mid-level drying near the pouch center in ex-Gaston. The mid-level drying suppresses deep convection, reduces moisture supply from the boundary layer, and contributes to the non-development of ex-Gaston. Three-dimensional trajectory analysis based on the numerical model simulation of Fay suggests that dry air entrained at the pouch periphery tends to stay off the pouch center due to the weak mid-level inflow or gets moistened along its path even if being wrapped into the wave pouch. Lateral entrainment in the middle troposphere thus does not suppress convection near the pouch center or prevent the development of Tropical Storm Fay. This study suggests that the upper troposphere is a weak spot of the wave pouch at the early formation stage and that the vertical transport is likely a more direct pathway for dry air to influence moist convection near the pouch center. Fig. 1 (a) 3 km relative humidity and storm relative streamlines for Gaston (2010) at 0800 UTC 05 September 2010 with a group of ensemble forward parcel trajectories (gray); (b) vertical cross section of RH along 17.5°N (contour intervals are set to 15%) and backward trajectories (gray) projected on the longitude-height plane. The box in (a) highlights a pocket of

  4. Modeling 3D conjugate heat and mass transfer for turbulent air drying of Chilean papaya in a direct contact dryer

    NASA Astrophysics Data System (ADS)

    Lemus-Mondaca, Roberto A.; Vega-Gálvez, Antonio; Zambra, Carlos E.; Moraga, Nelson O.

    2016-03-01

    A 3D model considering heat and mass transfer for food dehydration inside a direct contact dryer is studied. The k- ɛ model is used to describe turbulent air flow. The samples thermophysical properties as density, specific heat, and thermal conductivity are assumed to vary non-linearly with temperature. FVM, SIMPLE algorithm based on a FORTRAN code are used. Results unsteady velocity, temperature, moisture, kinetic energy and dissipation rate for the air flow are presented, whilst temperature and moisture values for the food also are presented. The validation procedure includes a comparison with experimental and numerical temperature and moisture content results obtained from experimental data, reaching a deviation 7-10 %. In addition, this turbulent k- ɛ model provided a better understanding of the transport phenomenon inside the dryer and sample.

  5. Passive air sampling of PCBs, PBDEs, and organochlorine pesticides across Europe.

    PubMed

    Jaward, Foday M; Farrar, Nick J; Harner, Tom; Sweetman, Andrew J; Jones, Kevin C

    2004-01-01

    This study presents concurrently sampled ambient air data for a range of persistent organic pollutants at the continental scale. This was achieved using a passive air sampling system, deploying polyurethane foam disks, which was prepared in one laboratory, sealed to prevent contamination, sent out by courier to volunteers participating in different countries, exposed for 6 weeks, collected, resealed, and returned to the laboratory for analysis. Europe was the study area--a region with a history of extensive POPs usage and emission and with marked national differences in population density, the degree of urbanization and industrial/agricultural development. Samplers were deployed at remote/rural/urban locations in 22 countries and analyzed for PCBs, a range of organochlorine pesticides (HCB, alpha-HCH, gamma-HCH, ppDDT, ppDDE), and PBDEs. Calculated air concentrations were in line with those obtained by conventional active air sampling techniques. The geographical pattern of all compounds reflected suspected regional emission patterns and highlighted localized hotspots. PCB and PBDE levels varied by over 2 orders of magnitude; the highest values were detected in areas of high usage and were linked to urbanized areas. HCB was relatively uniformly distributed, reflecting its persistence and high degree of mixing in air. Higher gamma-HCH, ppDDT, and ppDDE levels generally occurred in South and East Europe. PMID:14740714

  6. Valveless sampling of ambient air for analysis by capillary gas chromatography

    SciTech Connect

    Stephens, E.R. )

    1989-09-01

    A method for the high resolution, high sensitivity analysis of polluted air for individual organic compounds is described. Samples collected from 50 mL of ambient air at 87 K (liquid argon) are injected without use of a valve into a silica capillary column which is then temperature programmed from {minus}30{degree}C to 180{degree}C. Hydrocarbons (4 to 10 carbons) as well as carbonyl compounds, chlorinated compounds and terpenes can be identified and quantified. The detection limit, not strongly dependent on carbon number, is estimated to be 0.3 ppbc in a 50 mL sample. Use of small samples eliminates the need to remove water vapor, a procedure which might jeopardize sample integrity.

  7. Air Sampling System for use in monitoring viable and non-viable particulate air quality under dynamic operating conditions of blow/fill/seal processing.

    PubMed

    Probert, Steve; Sinclair, Colin S; Tallentire, Alan

    2002-01-01

    An Air Sampling Link (ASL), employed in conjunction with an Air Sampling Device (ASD) or a laser particle counter, has been developed for sampling flowing air for viable and non-viable particulate analyses. Typically, the ASL could be used to sample filtered air supplied to an air shower of a Blow/Fill/Seal machine operating in the dynamic state. The ASL allows sample volumes of air to be taken from flowing air without significant loss from the sample flow of airborne particles possessing aerodynamic sizes relevant to those found in practice. The link has no moving parts, is steam sterilizable in-situ, and allows for the taking of continuous samples of air without the need for intervention into the 'critical zone' of the filling machine. This article describes (i) the design criteria for the ASL and the ASD, (ii) the rationale underlying the concept of the ASL design, (iii) the collection performance of the ASL against that of a conventional sampling arrangement, and (iv) a functionality assessment of the ASL-based sampling system installed on a Rommelag style 305 B/F/S machine over a seven week period. PMID:12404722

  8. Development and calibration of real-time PCR for quantification of airborne microorganisms in air samples

    NASA Astrophysics Data System (ADS)

    An, Hey Reoun; Mainelis, Gediminas; White, Lori

    This manuscript describes the coupling of bioaerosol collection and the use of real-time PCR (RT-PCR) to quantify the airborne bacteria. The quantity of collected bacteria determined by RT-PCR is compared with conventional quantification techniques, such as culturing, microscopy and airborne microorganism counting by using optical particle counter (OPC). Our data show that an experimental approach used to develop standard curves for use with RT-PCR is critical for accurate sample quantification. Using universal primers we generated 12 different standard curves which were used to quantify model organism Escherichia coli (Migula) Catellani from air samples. Standard curves prepared using a traditional approach, where serially diluted genomic DNA extracted from pure cultured bacteria were used in PCR reaction as a template DNA yielded significant underestimation of sample quantities compared to airborne microorganism concentration as measured by an OPC. The underestimation was especially pronounced when standard curves were built using colony forming units (CFUs). In contrast, the estimate of cell concentration in an air sample by RT-PCR was more accurate (˜60% compared to the airborne microorganism concentration) when the standard curve was built using aerosolized E. coli. The accuracy improved even further (˜100%) when air samples used to build the standard curves were diluted first, then the DNA extracted from each dilution was amplified by the RT-PCR—to mimic the handling of air samples with unknown and possibly low concentration. Therefore, our data show that standard curves used for quantification by RT-PCR needs to be prepared using the same environmental matrix and procedures as handling of the environmental sample in question. Reliance on the standard curves generated with cultured bacterial suspension (a traditional approach) may lead to substantial underestimation of microorganism quantities in environmental samples.

  9. The effect of compressed air foam on the detection of hydrocarbon fuels in fire debris samples.

    PubMed

    Coulson, S A; Morgan-Smith, R K; Noble, D

    2000-01-01

    In 1998/99 the New Zealand Fire Service implemented compressed air foam delivery systems for the suppression of fires in rural areas. This study investigated whether the introduction of the foam to the seat of the fire created any problems in subsequent analyses of fire debris samples. No significant interferences from the foam were found when the samples were analysed by direct headspace using activated carbon strips. The only foam component detected was limonene. PMID:11094822

  10. Curve fitting air sample filter decay curves to estimate transuranic content.

    PubMed

    Hayes, Robert B; Chiou, Hung Cheng

    2004-01-01

    By testing industry standard techniques for radon progeny evaluation on air sample filters, a new technique is developed to evaluate transuranic activity on air filters by curve fitting the decay curves. The industry method modified here is simply the use of filter activity measurements at different times to estimate the air concentrations of radon progeny. The primary modification was to not look for specific radon progeny values but rather transuranic activity. By using a method that will provide reasonably conservative estimates of the transuranic activity present on a filter, some credit for the decay curve shape can then be taken. By carrying out rigorous statistical analysis of the curve fits to over 65 samples having no transuranic activity taken over a 10-mo period, an optimization of the fitting function and quality tests for this purpose was attained. PMID:14695010

  11. ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

    SciTech Connect

    Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

    2011-06-07

    Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear ES

  12. Measured performance of the heat exchanger in the NASA icing research tunnel under severe icing and dry-air conditions

    NASA Technical Reports Server (NTRS)

    Olsen, W.; Vanfossen, J.; Nussle, R.

    1987-01-01

    Measurements were made of the pressure drop and thermal perfomance of the unique refrigeration heat exchanger in the NASA Lewis Icing Research Tunnel (IRT) under severe icing and frosting conditions and also with dry air. This data will be useful to those planning to use or extend the capability of the IRT and other icing facilities (e.g., the Altitude Wind Tunnel-AWT). The IRT heat exchanger and refrigeration system is able to cool air passing through the test section down to at least a total temperature of -30 C (well below icing requirements), and usually up to -2 C. The system maintains a uniform temperature across the test section at all airspeeds, which is more difficult and time consuming at low airspeeds, at high temperatures, and on hot, humid days when the cooling towers are less efficient. The very small surfaces of the heat exchanger prevent any icing cloud droplets from passing through it and going through the tests section again. The IRT heat exchanger was originally designed not to be adversely affected by severe icing. During a worst-case icing test the heat exchanger iced up enough so that the temperature uniformaity was no worse than about +/- 1 deg C. The conclusion is that the heat exchanger design performs well.

  13. Simplifying sample pretreatment: application of dried blood spot (DBS) method to blood samples, including postmortem, for UHPLC-MS/MS analysis of drugs of abuse.

    PubMed

    Odoardi, Sara; Anzillotti, Luca; Strano-Rossi, Sabina

    2014-10-01

    The complexity of biological matrices, such as blood, requires the development of suitably selective and reliable sample pretreatment procedures prior to their instrumental analysis. A method has been developed for the analysis of drugs of abuse and their metabolites from different chemical classes (opiates, methadone, fentanyl and analogues, cocaine, amphetamines and amphetamine-like substances, ketamine, LSD) in human blood using dried blood spot (DBS) and subsequent UHPLC-MS/MS analysis. DBS extraction required only 100μL of sample, added with the internal standards and then three droplets (30μL each) of this solution were spotted on the card, let dry for 1h, punched and extracted with methanol with 0.1% of formic acid. The supernatant was evaporated and the residue was then reconstituted in 100μL of water with 0.1% of formic acid and injected in the UHPLC-MS/MS system. The method was validated considering the following parameters: LOD and LOQ, linearity, precision, accuracy, matrix effect and dilution integrity. LODs were 0.05-1ng/mL and LOQs were 0.2-2ng/mL. The method showed satisfactory linearity for all substances, with determination coefficients always higher than 0.99. Intra and inter day precision, accuracy, matrix effect and dilution integrity were acceptable for all the studied substances. The addition of internal standards before DBS extraction and the deposition of a fixed volume of blood on the filter cards ensured the accurate quantification of the analytes. The validated method was then applied to authentic postmortem blood samples. PMID:24814508

  14. Development of a wireless air pollution sensor package for aerial-sampling of emissions

    EPA Science Inventory

    A new sensor system for mobile and aerial emission sampling was developed for open area pollutant sources, such as prescribed forest burns. The sensor system, termed “Kolibri”, consists of multiple low-cost air quality sensors measuring CO2, CO, samplers for particulate matter wi...

  15. the nature of air flow near the inlets of blunt dust sampling probes

    NASA Astrophysics Data System (ADS)

    Vincent, J. H.; Hutson, D.; Mark, D.

    This paper sets out to describe the nature of air flow near blunt dust samplers in a way which allows a relatively simple assessment of their performances for collecting dust particles. Of particular importance is the shape of the limiting stream surface which divides the sampled air from that which passes outside the sampler, and how this is affected by the free-stream air velocity, the sampling flow rate, and the shape of the sampler body. This was investigated for two-dimensional and axially-symmetric sampler systems by means of complementary experiments using electrolytic tank potential flow analogues and a wind tunnel respectively. For extreme conditions the flow of air entering the sampling orifice may be wholly divergent or wholly convergent. For a wide range of intermediate conditions, however, the flow first diverges then converges, exhibiting a so-called "spring onion effect". Whichever of these applies for a particular situation, the flow may be considered to consist of two parts, the outer one dominated by the flow about the sampler body and the inner one dominated by the flow into the sampling orifice. Particle transport in this two-part flow may be assessed using ideas borrowed from thin-walled probe theory.

  16. INTERCOMPARISON OF SAMPLING TECHNIQUES FOR TOXIC ORGANIC COMPOUNDS IN INDOOR AIR

    EPA Science Inventory

    People spend a major fraction of their time indoors, and there is concern over exposure to volatile organic compounds present in indoor air. The study was initiated to compare several VOC sampling techniques in an indoor environment. The techniques which were compared include dis...

  17. Development of a wireless air pollution sensor package for aerial-sampling of emissions

    EPA Science Inventory

    A new sensor system for mobile and aerial emission sampling was developed for open area pollutant sources, such as prescribed forest burns. The sensor system, termed “Kolibri”, consists of multiple low-cost air quality sensors measuring CO2, CO, samplers for particula...

  18. COMPARISON OF FAST GC/TOFMS WITH METHOD TO-14 FOR ANALYSIS OF AMBIENT AIR SAMPLES

    EPA Science Inventory

    Field studies using portable gas chromatographs (PGC) to analyze volatile organic compounds in ambient air usually include, as reference standard method, the analysis of concurrent, collocated canister samples by EPA Method TO-14. Each laboratory analysis takes about an hour a...

  19. INDOOR AIR SAMPLING AND MUTAGENICITY STUDIES OF EMISSIONS FROM UNVENTED COAL COMBUSTION (JOURNAL VERSION)

    EPA Science Inventory

    The purpose of the study is to develop sampling strategies and bioassay methods for indoor air in homes, the authors developed a medium-volume sampler to collect the <10 - micrometers particulate matter and semivolatile organics, and used high-volume particulate sampler for compa...

  20. COMPARISON OF MOLD CONCENTRATIONS IN INDOOR AND OUTDOOR AIR SAMPLED SIMULTANEOUSLY AND THEN QUANTIFIED BY MSQPCR

    EPA Science Inventory

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of the 36 mold species in indoor and outdoor air samples that were taken simultaneously for 48 hours in and around 17 homes in Cincinnati, Ohio. The total spore concentrations of 353 per m3...

  1. CLEANLINESS OF COMMON AIR SAMPLING SORBENTS FOR APPLICATION TO PHENOLIC COMPOUNDS MEASUREMENT USING SUPERCRITICAL FLUID EXTRACTION

    EPA Science Inventory

    The trace-level measurement of phenolic compounds in the ambient air is complicated by the acidic and polar nature of the compounds especially during recovery from the sampling medium. ecently, supercritical fluid extraction (SFE) has been proposed as an alternative extraction me...

  2. NON-POLAR VOLATILE ORGANIC COMPOUNDS IN WHOLE AIR SAMPLES FROM THE AUTOEX STUDIES

    EPA Science Inventory

    Air samples were captured in SUMMA polished stainless steel canisters and returned to the laboratory for analysis of trace level volatile organic compounds by gas chromatography - mass spectrometry. ampling was performed over 2-hour periods at various distances from heavily trave...

  3. Collecting Samples of Workplace Air. Module 8. Vocational Education Training in Environmental Health Sciences.

    ERIC Educational Resources Information Center

    Consumer Dynamics Inc., Rockville, MD.

    This module, one of 25 on vocational education training for careers in environmental health occupations, contains self-instructional materials on collecting samples of workplace air. Following guidelines for students and instructors and an introduction that explains what the student will learn are three lessons: (1) collecting information about…

  4. Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample Collection

    PubMed Central

    Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.

    2016-01-01

    To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691

  5. The impact of freeze-drying infant fecal samples on measures of their bacterial community profiles and milk-derived oligosaccharide content

    PubMed Central

    Lewis, Zachery T.; Davis, Jasmine C.C.; Smilowitz, Jennifer T.; German, J. Bruce; Lebrilla, Carlito B.

    2016-01-01

    Infant fecal samples are commonly studied to investigate the impacts of breastfeeding on the development of the microbiota and subsequent health effects. Comparisons of infants living in different geographic regions and environmental contexts are needed to aid our understanding of evolutionarily-selected milk adaptations. However, the preservation of fecal samples from individuals in remote locales until they can be processed can be a challenge. Freeze-drying (lyophilization) offers a cost-effective way to preserve some biological samples for transport and analysis at a later date. Currently, it is unknown what, if any, biases are introduced into various analyses by the freeze-drying process. Here, we investigated how freeze-drying affected analysis of two relevant and intertwined aspects of infant fecal samples, marker gene amplicon sequencing of the bacterial community and the fecal oligosaccharide profile (undigested human milk oligosaccharides). No differences were discovered between the fecal oligosaccharide profiles of wet and freeze-dried samples. The marker gene sequencing data showed an increase in proportional representation of Bacteriodes and a decrease in detection of bifidobacteria and members of class Bacilli after freeze-drying. This sample treatment bias may possibly be related to the cell morphology of these different taxa (Gram status). However, these effects did not overwhelm the natural variation among individuals, as the community data still strongly grouped by subject and not by freeze-drying status. We also found that compensating for sample concentration during freeze-drying, while not necessary, was also not detrimental. Freeze-drying may therefore be an acceptable method of sample preservation and mass reduction for some studies of microbial ecology and milk glycan analysis. PMID:26819854

  6. An improved high performance liquid chromatography-photodiode array detection-atmospheric pressure chemical ionization-mass spectrometry method for determination of chlorophylls and their derivatives in freeze-dried and hot-air-dried Rhinacanthus nasutus (L.) Kurz.

    PubMed

    Kao, Tsai Hua; Chen, Chia Ju; Chen, Bing Huei

    2011-10-30

    Rhinacanthus nasutus (L.) Kurz, a traditional Chinese herb possessing antioxidant and anti-cancer activities, has been reported to contain functional components like carotenoids and chlorophylls. However, the variety and amount of chlorophylls remain uncertain. The objectives of this study were to develop a high performance liquid chromatography-photodiode array detection-atmospheric pressure chemical ionization-mass spectrometry (HPLC-DAD-APCI-MS) method for determination of chlorophylls and their derivatives in hot-air-dried and freeze-dried R. nasutus. An Agilent Eclipse XDB-C18 column and a gradient mobile phase composed of methanol/N,N-dimethylformamide (97:3, v/v), acetonitrile and acetone were employed to separate internal standard zinc-phthalocyanine plus 12 cholorophylls and their derivatives within 21 min, including chlorophyll a, chlorophyll a', hydroxychlorophyll a, 15-OH-lactone chlorophyll a, chlorophyll b, chlorophyll b', hydroxychlorophyll b, pheophytin a, pheophytin a', hydroxypheophytin a, hydroxypheophytin a' and pheophytin b in hot-air-dried R. nasutus with flow rate at 1 mL/min and detection at 660 nm. But, in freeze-dried R. nasutus, only 4 chlorophylls and their derivatives, including chlorophyll a, chlorophyll a', chlorophyll b and pheophytin a were detected. Zinc-phthalocyanine was found to be an appropriate internal standard to quantify all the chlorophyll compounds. After quantification by HPLC-DAD, both chlorophyll a and pheophytin a were the most abundant in hot-air-dried R. nasutus, while in freeze-dried R. nasutus, chlorophyll a and chlorophyll b dominated. PMID:22063550

  7. Rapid High Throughput Amylose Determination in Freeze Dried Potato Tuber Samples

    PubMed Central

    Fajardo, Diego; Jayanty, Sastry S.; Jansky, Shelley H.

    2013-01-01

    This protocol describes a high through put colorimetric method that relies on the formation of a complex between iodine and chains of glucose molecules in starch. Iodine forms complexes with both amylose and long chains within amylopectin. After the addition of iodine to a starch sample, the maximum absorption of amylose and amylopectin occurs at 620 and 550 nm, respectively. The amylose/amylopectin ratio can be estimated from the ratio of the 620 and 550 nm absorbance values and comparing them to a standard curve in which specific known concentrations are plotted against absorption values. This high throughput, inexpensive method is reliable and reproducible, allowing the evaluation of large populations of potato clones.  PMID:24145574

  8. Whole Air Sampling During NASA's March-April 1999 Pacific Exploratory Expedition (PEM-Tropics B)

    NASA Technical Reports Server (NTRS)

    Blake, Donald R.

    2001-01-01

    University of California, Irvine (UCI) collected more than 4500 samples whole air samples collected over the remote Pacific Ocean during NASA's Global Tropospheric Experiment (GTE) Pacific Exploratory Mission-Tropics B (PEM-Tropics B) in March and early April 1999. Approximately 140 samples during a typical 8-hour DC-8 flight, and 120 canisters for each 8-hour flight aboard the P-3B. These samples were obtained roughly every 3-7 min during horizontal flight legs and 1-3 min during vertical legs. The filled canisters were analyzed in the laboratory at UCI within ten days of collection. The mixing ratios of 58 trace gases comprising hydrocarbons, halocarbons, alkyl nitrates and DMS were reported (and archived) for each sample. Two identical analytical systems sharing the same standards were operated simultaneously around the clock to improve canister turn-around time and to keep our measurement precision optimal. This report presents a summary of the results for sample collected.

  9. Determination of selected heavy metals in air samples from the northern part of Jordan.

    PubMed

    Gharaibeh, Ahmad A; El-Rjoob, Abdul-Wahab O; Harb, Mohammed K

    2010-01-01

    In this work, the atmospheric concentrations of selected heavy metals including lead (Pb), iron (Fe), cadmium (Cd), copper (Cu), nickel (Ni), manganese (Mn), and zinc (Zn) were measured for two different sampling sites (urban and rural) in the northern part of Jordan (Irbid city). Samples were collected according to a certain schedule for 1 year. High volume air samplers and glass fiber filters were used to collect the samples. Collected samples were digested using a mixture of analytical grade nitric acid and analytical grade hydrochloric acid, and analyzed to evaluate the levels of heavy metals by atomic absorption spectrophotometry. Six heavy metals (Pb, Fe, Cu, Ni, Mn, and Zn) were measured in all samples; the concentrations of Cd and Co were not detected in Irbid atmosphere by atomic absorption spectroscopy. The results were used to determine the levels of heavy metal pollutants in air, possible sources, and to compare the levels of selected heavy metals in the two studied sites. Aerosols from the rural site have lower concentrations for all the metals compared to those from the urban site. The daily and monthly variations of the elements were investigated. All heavy metals in urban and rural sites reached maximum concentrations in June, July, and August. This is consistent with the increased activities leading to particulate matter emission during the summer period. The enrichment factors with respect to earth crust and correlation coefficients of heavy metals were investigated to predict the possible sources of heavy metals in air. PMID:19083108

  10. Chemical reactivities of ambient air samples in three Southern California communities

    PubMed Central

    Eiguren-Fernandez, Arantza; Di Stefano, Emma; Schmitz, Debra A.; Guarieiro, Aline Lefol Nani; Salinas, Erika M.; Nasser, Elina; Froines, John R.; Cho, Arthur K.

    2015-01-01

    The potential adverse health effects of PM2.5 and vapor samples from three communities that neighbor railyards, Commerce (CM), Long Beach (LB), and San Bernardino (SB), were assessed by determination of chemical reactivities attributed to the induction of oxidative stress by air pollutants. The assays used were dithiothreitol (DTT) and dihydrobenzoic acid (DHBA) based procedures for prooxidant content and a glyceraldehyde-3-phosphate dehydrogenase (GAPDH) assay for electrophiles. Prooxidants and electrophiles have been proposed as the reactive chemical species responsible for the induction of oxidative stress by air pollution mixtures. The PM2.5 samples from CM and LB sites showed seasonal differences in reactivities with higher levels in the winter whereas the SB sample differences were reversed. The reactivities in the vapor samples were all very similar, except for the summer SB samples, which contained higher levels of both prooxidants and electrophiles. The results suggest the observed reactivities reflect general geographical differences rather than direct effects of the railyards. Distributional differences in reactivities were also observed with PM2.5 fractions containing most of the prooxidants (74–81%) and the vapor phase most of the electrophiles (82–96%). The high levels of the vapor phase electrophiles and their potential for adverse biological effects point out the importance of the vapor phase in assessing the potential health effects of ambient air. PMID:25947123

  11. Mathematical Estimation of the Level of Microbial Contamination on Spacecraft Surfaces by Volumetric Air Sampling

    PubMed Central

    Oxborrow, G. S.; Roark, A. L.; Fields, N. D.; Puleo, J. R.

    1974-01-01

    Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model. PMID:4151118

  12. Mathematical estimation of the level of microbial contamination on spacecraft surfaces by volumetric air sampling

    NASA Technical Reports Server (NTRS)

    Oxborrow, G. S.; Roark, A. L.; Fields, N. D.; Puleo, J. R.

    1974-01-01

    Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model.

  13. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    SciTech Connect

    MULKEY, C.H.

    1999-07-06

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants.

  14. Report on sampling and analysis of exhaust air at the 221-T and 2706-T buildings

    SciTech Connect

    Stauffer, M.

    1997-09-22

    This report presents analytical results from exhaust air samples collected at stacks 221-T and 2706-T of the T-Plant. The samples were collected with SUMMA canisters over a 24 hour interval and were analyzed by gas chromatography-mass spectrometry using a modified EPA TO-14 procedure. The data suggest that the buildings had generally low concentrations of volatile organic compounds (< 40 ppbv). However, samples from building 2706-T did have significant amounts of non-target higher-boiling hydrocarbons, probably from a petroleum destination fraction.

  15. High-throughput liquid-absorption air-sampling apparatus and methods

    SciTech Connect

    2000-07-11

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is < 10 cm of water, usually < 5 cm of water. The sampler's collection efficiency is usually > 20% for vapors or airborne particulates in the 2--3 microns range and > 50% for particles larger than 4 microns. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  16. High-throughput liquid-absorption air-sampling apparatus and methods

    DOEpatents

    Zaromb, Solomon

    2000-01-01

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is <10 cm of water, usually <5 cm of water. The sampler's collection efficiency is usually >20% for vapors or airborne particulates in the 2-3.mu. range and >50% for particles larger than 4.mu.. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  17. Water and entrapped air redistribution in heterogeneous sand sample: Quantitative neutron imaging of the process

    NASA Astrophysics Data System (ADS)

    Snehota, Michal; Jelinkova, Vladimira; Sobotkova, Martina; Sacha, Jan; Vontobel, Peter; Hovind, Jan

    2015-02-01

    Saturated flow in soil with the occurrence of preferential flow often exhibits temporal changes of saturated hydraulic conductivity even during the time scale of a single infiltration event. These effects, observed in a number of experiments done mainly on heterogeneous soils, are often attributed to the changing distribution of water and air in the sample. We have measured the variation of the flow rates during the steady state stage of the constant head ponded infiltration experiment conducted on a packed sample composed of three different grades of sand. The experiment was monitored by quantitative neutron imaging, which provided information about the spatial distribution of water in the sample. Measurements were taken during (i) the initial stages of infiltration by neutron radiography and (ii) during the steady state flow by neutron tomography. A gradual decrease of the hydraulic conductivity has been observed during the first 4 h of the infiltration event. A series of neutron tomography images taken during the quasi-steady state stage showed the trapping of air bubbles in coarser sand. Furthermore, the water content in the coarse sand decreased even more while the water content in the embedded fine sand blocks gradually increased. The experimental results support the hypothesis that the effect of the gradual hydraulic conductivity decrease is caused by entrapped air redistribution and the build up of bubbles in preferential pathways. The trapped air thus restricts the preferential flow pathways and causes lower hydraulic conductivity.

  18. Volatile organic components of air samples collected from Vertical Launch Missile capsules. Summary report

    SciTech Connect

    Tappan, D.V.; Knight, D.R.; Heyder, E.; Weathersby, P.K.

    1988-09-27

    Gas chromatographic/mass spectroscopic analyses are presented for the volatile organic components found in air samples collected from the inboard vents from Vertical Launch System (VLS) missile capsules aboard a 688 class submarine. Similar analyses were also conducted for a sample of the ship's high pressure air used to fill the missile tubes. A wide variety of organics was detected in the air from the missile capsules; and while no unique components have yet been identified, a significant contribution has been shown to be made by pressure-ventilation of the VLS capsules into the submarine atmosphere which is already heavily laden with volatile organic compounds. The most apparent conclusion from these preliminary analyses is that the mixtures of organic components in the air within VLS missile capsules vary greatly from capsule to capsule (and probably from time to time). Many such samples need to be investigated to provide sufficient information to judge the seriousness of the possibility of venting toxic components into the submarine atmosphere during the maintenance or firing of VLS missiles.

  19. Soyuz 22 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Jams, John T.

    2010-01-01

    Three mini-grab sample containers (m-GSCs) were returned aboard Soyuz 22 because of concerns that new air pollutants were present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The toxicological assessment of 3 m-GSCs from the ISS is shown in Table 1. The recoveries of the 3 standards (as listed above) from the GSCs averaged 103, 95 and 76%, respectively. Recovery from formaldehyde control badges were 90 and 91%.

  20. Electronic Nose and Use of Bags to Collect Odorous Air Samples in Meat Quality Analysis

    NASA Astrophysics Data System (ADS)

    Sala, G.; Masoero, G.; Battaglini, L. M.; Cornale, P.; Barbera, S.

    2009-05-01

    To test EN reliability and use of bags on meat, 17 bulls (one group of 9 and one of 8) fed similarly, except for a supplementary feedingstuff, were used. Samples were prepared according to the MCS protocol and repeated three times on different days for a total of 51 samples. Bags were used to collect raw and cooked meat air samples, and to test odour changes among samples analysed at different times. The first time analysis was performed immediately after collection then was repeated, 1 hour, 1 day and 1 week later. The Electronic Nose is very discriminant and clear differences were evident among raw, cooked and bags odorous profiles. The highest values were found in cooked samples and the broad range class (W5S) was the most representative. The EN also recognized the two tested feed treatments. In the cooked samples, all sensor responses decrease while time enhances, indicating a progressive chemical variation of the air composition in the bag, with a less correlation shown in the raw samples. When using bags, to avoid bias, is important to fix analysis in order to obtain useful results.

  1. CONCENTRATION OF TETRACHLOROETHYLENE IN INDOOR AIR AT A FORMER DRY CLEANER FACILITY AS A FUNCTION OF SUBSURFACE CONTAMINATION: A CASE STUDY

    EPA Science Inventory

    A field study was performed to evaluate indoor air concentrations and vapor intrusion (VI) of tetrachloroethylene (PCE) and other chlorinated solvents at a commercial retail site in Dallas, TX. The building is approximately 40 years old and once housed a dry cleaning operation. R...

  2. EFFECT OF DRY AIR CHILLING ON WARNER-BRATZLER SHEAR FORCE AND WATER-HOLDING CAPACITY OF BROILER MEAT DEBONED FOUR HOURS POSTMORTEM

    Technology Transfer Automated Retrieval System (TEKTRAN)

    TECHNICAL ABSTRACT Advantages of air chilling (AC) methods over immersion chilling (IC) methods in quality retention and improvement of deboned chicken breast meat depends on experimental conditions, such as deboning time. The objective of this study was to evaluate the effect of a dry-AC method on ...

  3. Diffusive sampling and measurement of microbial volatile organic compounds in indoor air.

    PubMed

    Araki, A; Eitaki, Y; Kawai, T; Kanazawa, A; Takeda, M; Kishi, R

    2009-10-01

    Microbial volatile organic compounds (MVOC), chemicals emitted from various microorganisms, in indoor air have been of concern in recent years. For large field studies, diffusive samplers are widely used to measure indoor environments. Since the sampling rate of a sampler is a fundamental parameter to calculate concentration, the sampling rates of eight MVOC with diffusive samplers were determined experimentally using a newly developed water-bubbling method: air was supplied to the MVOC-solutions and the vapor collected in an exposure bag, where diffusive and active samplers were placed in parallel for comparison. Correlations between the diffusive and active samplings gave good linear regressions. The sampling rates were 30-35 ml/min and the detection limits were 0.044-0.178 microg/m(3), as determined by GC/MS analysis. Application of the sampling rates in indoor air was validated by parallel sampling of the diffusive and active sampling method. 5% Propan-2-ol/CS(2) was the best solvent to desorb the compounds from absorbents. The procedure was applied to a field study in 41 dwellings. The most frequently detected compounds were hexan-2-one and heptan-2-one, with 97.5% detection rates and geometric mean values of 0.470 and 0.302 microg/m(3), respectively. This study shows that diffusive samplers are applicable to measure indoor MVOC levels. Practical Implications At present, there are still limited reports on indoor Microbial Volatile Organic Compounds (MVOC) levels in general dwellings and occupants' health. Compared with active sampling methods, air sampling using a diffusive sampler is particularly advantageous for use in large field studies due to its smallness, light-size, easy-handling, and cost-effectiveness. In this study, sampling rates of selected MVOC of the diffusive sampler were determined using the water-bubbling method: generating gases by water-bubbling and exposing the diffusive and active samplers at the same time. The obtained sampling rates

  4. Air

    MedlinePlus

    ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be polluted indoors and it can ... this chart to see what things cause indoor air pollution and what things cause outdoor air pollution! Indoor ...

  5. Identification of Chromium Resistant Bacteria from Dry Fly Ash Sample of Mejia MTPS Thermal Power Plant, West Bengal, India.

    PubMed

    Roychowdhury, Roopali; Mukherjee, Pritam; Roy, Madhumita

    2016-02-01

    Eight chromium resistant bacteria were isolated from a dry fly ash sample of DVC-MTPS thermal power plant located in Bankura, West Bengal, India. These isolates displayed different degrees of chromate reduction under aerobic conditions. According to 16S rDNA gene analysis, five of them were Staphylococcus, two were Bacillus and one was Micrococcus. The minimum inhibitory concentration towards chromium and the ability to reduce hexavalent chromium to trivalent chromium was highest in Staphylococcus haemolyticus strain HMR17. All the strains were resistant to multiple heavy metals (As, Cu, Cd, Co, Zn, Mn, Pb and Fe) and reduced toxic hexavalent chromium to relatively non toxic trivalent chromium even in the presence of these multiple heavy metals. All of them showed resistance to different antibiotics. In a soil microcosm study, S. haemolyticus strain HMR17 completely reduced 4 mM hexavalent chromium within 7 days of incubation. PMID:26602566

  6. DNA Barcode Authentication of Wood Samples of Threatened and Commercial Timber Trees within the Tropical Dry Evergreen Forest of India

    PubMed Central

    Nithaniyal, Stalin; Newmaster, Steven G.; Ragupathy, Subramanyam; Krishnamoorthy, Devanathan; Vassou, Sophie Lorraine; Parani, Madasamy

    2014-01-01

    Background India is rich with biodiversity, which includes a large number of endemic, rare and threatened plant species. Previous studies have used DNA barcoding to inventory species for applications in biodiversity monitoring, conservation impact assessment, monitoring of illegal trading, authentication of traded medicinal plants etc. This is the first tropical dry evergreen forest (TDEF) barcode study in the World and the first attempt to assemble a reference barcode library for the trees of India as part of a larger project initiated by this research group. Methodology/Principal Findings We sampled 429 trees representing 143 tropical dry evergreen forest (TDEF) species, which included 16 threatened species. DNA barcoding was completed using rbcL and matK markers. The tiered approach (1st tier rbcL; 2nd tier matK) correctly identified 136 out of 143 species (95%). This high level of species resolution was largely due to the fact that the tree species were taxonomically diverse in the TDEF. Ability to resolve taxonomically diverse tree species of TDEF was comparable among the best match method, the phylogenetic method, and the characteristic attribute organization system method. Conclusions We demonstrated the utility of the TDEF reference barcode library to authenticate wood samples from timber operations in the TDEF. This pilot research study will enable more comprehensive surveys of the illegal timber trade of threatened species in the TDEF. This TDEF reference barcode library also contains trees that have medicinal properties, which could be used to monitor unsustainable and indiscriminate collection of plants from the wild for their medicinal value. PMID:25259794

  7. Greenhouse gas analysis of air samples collected onboard the CARIBIC passenger aircraft

    NASA Astrophysics Data System (ADS)

    Schuck, T. J.; Brenninkmeijer, C. A. M.; Slemr, F.; Xueref-Remy, I.; Zahn, A.

    2009-08-01

    CARIBIC (Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container) is a long-term atmospheric measurement program based on the use of a comprehensive scientific instrument package aboard a commercial passenger aircraft. In addition to real-time measurements, whole air sampling is performed regularly at cruising altitudes in the tropical middle troposphere and the extra-tropical UT/LS region. Air samples are analyzed for greenhouse gases, NMHCs, halocarbons, and trace gas isotopic composition. The routinely performed greenhouse gas analysis comprises gas chromatography measurements of CO2, CH4, N2O and SF6. The air sampling procedure, the GC system and its performance are described. Comparisons with similar systems employed in other laboratories and a comparison with results from a CO2 in-situ analyzer that is also part of the CARIBIC instrumentation are shown. In addition, the time series of CO2, obtained from the collection of 684 samples at latitudes between 30° N and 56° N on 21 round trips out of Germany to different destinations in Asia between November 2005 and October 2008, is presented. A time shift in the seasonal cycle of about one month was observed between the upper troposphere and the tropopause region. For two sets of return flights from Germany to the Philippines the relationship between the four greenhouse gases is briefly discussed.

  8. Calibration of laser ablation inductively coupled plasma mass spectrometry using dried solution aerosols for the quantitative analysis of solid samples

    SciTech Connect

    Leach, J.

    1999-02-12

    Inductively coupled plasma mass spectrometry (ICP-MS) has become the method of choice for elemental and isotopic analysis. Several factors contribute to its success. Modern instruments are capable of routine analysis at part per trillion levels with relative detection limits in part per quadrillion levels. Sensitivities in these instruments can be as high as 200 million counts per second per part per million with linear dynamic ranges up to eight orders of magnitude. With standards for only a few elements, rapid semiquantitative analysis of over 70 elements in an individual sample can be performed. Less than 20 years after its inception ICP-MS has shown to be applicable to several areas of science. These include geochemistry, the nuclear industry, environmental chemistry, clinical chemistry, the semiconductor industry, and forensic chemistry. In this introduction, the general attributes of ICP-MS will be discussed in terms of instrumentation and sample introduction. The advantages and disadvantages of current systems are presented. A detailed description of one method of sample introduction, laser ablation, is given. The paper also gives conclusions and suggestions for future work. Chapter 2, Quantitative analysis of solids by laser ablation inductively coupled plasma mass spectrometry using dried solution aerosols for calibration, has been removed for separate processing.

  9. Interlaboratory evaluation of cellulosic acid-soluble internal air sampling capsules for multi-element analysis.

    PubMed

    Andrews, Ronnee N; Feng, H Amy; Ashley, Kevin

    2016-01-01

    An interlaboratory study was carried out to evaluate the use of acid-soluble cellulosic air sampling capsules for their suitability in the measurement of trace elements in workplace atmospheric samples. These capsules are used as inserts to perform closed-face cassette sample collection for occupational exposure monitoring. The interlaboratory study was performed in accordance with NIOSH guidelines that describe statistical procedures for evaluating measurement accuracy of air monitoring methods. The performance evaluation materials used consisted of cellulose acetate capsules melded to mixed-cellulose ester filters that were dosed with multiple elements from commercial standard aqueous solutions. The cellulosic capsules were spiked with the following 33 elements of interest in workplace air monitoring: Ag, Al, As, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, In, K, La, Li, Mg, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Sr, Te, Ti, Tl, V, W, Y, Zn, Zr. The elemental loading levels were certified by an accredited provider of certified reference materials. Triplicates of media blanks and multielement-spiked capsules at three different elemental loadings were sent to each participating laboratory; the elemental loading levels were not revealed to the laboratories. The volunteer participating laboratories were asked to prepare the samples by acid dissolution and to analyze aliquots of extracted samples by inductively coupled plasma atomic emission spectrometry in accordance with NIOSH methods. It was requested that the study participants report their analytical results in units of μg of each target element per internal capsule sample. For the majority of the elements investigated (30 out of 33), the study accuracy estimates obtained satisfied the NIOSH accuracy criterion (A < 25%). This investigation demonstrates the utility of acid-soluble internal sampling capsules for multielement analysis by atomic spectrometry. PMID:26308974

  10. Dried blood spots and sparse sampling: a practical approach to estimating pharmacokinetic parameters of caffeine in preterm infants

    PubMed Central

    Patel, Parul; Mulla, Hussain; Kairamkonda, Venkatesh; Spooner, Neil; Gade, Sonya; Della Pasqua, Oscar; Field, David J.; Pandya, Hitesh C.

    2013-01-01

    Aims Dried blood spots (DBS) alongside micro‐analytical techniques are a potential solution to the challenges of performing pharmacokinetic (PK) studies in children. However, DBS methods have received little formal evaluation in clinical settings relevant to children. The aim of the present study was to determine a PK model for caffeine using a ‘DBS/microvolume platform’ in preterm infants. Methods DBS samples were collected prospectively from premature babies receiving caffeine for treatment of apnoea of prematurity. A non‐linear mixed effects approach was used to develop a population PK model from measured DBS caffeine concentrations. Caffeine PK parameter estimates based on DBS data were then compared with plasma estimates for agreement. Results Three hundred and thirty‐eight DBS cards for caffeine measurement were collected from 67 preterm infants (birth weight 0.6–2.11 kg). 88% of cards obtained were of acceptable quality and no child had more than 10 DBS samples or more than 0.5 ml of blood taken over the study period. There was good agreement between PK parameters estimated using caffeine concentrations from DBS samples (CL = 7.3 ml h−1 kg−1; V = 593 ml kg−1; t1/2 = 57 h) and historical caffeine PK parameter estimates based on plasma samples (CL = 4.9–7.9 ml h−1 kg−1; V = 640–970 ml kg−1; t1/2 = 101–144 h). We also found that changes in blood haematocrit may significantly confound estimates of caffeine PK parameters based on DBS data. Conclusions This study demonstrates that DBS methods can be applied to PK studies in a vulnerable population group and are a practical alternative to wet matrix sampling techniques. PMID:22822712

  11. Determination of cross-grain properties of clearwood samples under kiln-drying conditions at temperature up to 140 C

    SciTech Connect

    Keep, L.B.; Keey, R.B.

    2000-07-01

    Small specimens of Pinus radiata have been tested to determine the creep strain that occurs during the kiln drying of boards. The samples have been tested over a range of temperatures from 20 C to 140 C. The samples, measuring 150 x 50 x 5 mm, were conditioned at various relative humidities in a pilot-plant kiln, in which the experiments at constant moisture content (MC) in the range of 5--20% MC were undertaken to eliminate mechano-sorptive strains. To determine the creep strain, the samples were brought to their equilibrium moisture content (EMC), then mechanically loaded under tension in the direction perpendicular to the grain. The strain was measured using small linear position sensors (LPS) which detect any elongation or shrinkage in the sample. The instantaneous compliance was measured within 60 sec of the application of the load (stress). The subsequent creep was monitored by the continued logging of strain data from the LPS units. The results of these experiments are consistent with previous studies of Wu and Milota (1995) on Douglas-fir (Pseudotsuga Menziesii). An increase in temperature or moisture content causes a rise in the creep strain while the sample is under tension. Values for the instantaneous compliance range from 1.7 x 10{sup {minus}3} to 1.28 x 10{sup {minus}2} M/Pa at temperatures between 20 C and 140 C and moisture content in the range of 5--20%. The rates of change of the creep strains are in the order of magnitude 10{sup {minus}7} to 10{sup {minus}8 s{sup {minus}1}} for these temperatures and moisture contents. The experimental data have been fitted to the constitutive equations of Wu and Milota (1996) for Douglas-fir to give material parameters for the instantaneous and creep strain components for Pinus radiata.

  12. Stability of HIV-1 Nucleic Acids in Dried Blood Spot Samples for HIV-1 Drug Resistance Genotyping

    PubMed Central

    Aitken, Susan C.; Wallis, Carole L.; Stevens, Wendy; de Wit, Tobias Rinke; Schuurman, Rob

    2015-01-01

    Dried blood spots (DBS) are an easy to collect sample-type that can stabilize biological material at ambient temperature for transport and storage, making them ideal for use in resource-limited settings (RLS). We investigated the effect of storage temperature and duration on ability to detect mixed HIV-1 viral RNA populations, and subsequently viral RNA populations in a background of proviral DNA. Part one of the study used DBS samples of whole blood spiked with specific quantities of HIV-1 subtype-B and -C RNA to study mixed virus population detection. Part two used DBS comprising of HIV-1 subtype-B proviral DNA containing U1 cells combined with HIV-1 subtype-C RNA to mimic HIV-1 infected clinical samples as a model system to study the relative stability of HIV-1 RNA and DNA in DBS. Prepared DBS were stored at -20°C and +30°C for periods of one day, one, two, and four weeks. Samples were genotyped to determine changes in the detection of mixtures in the sample over time. From two weeks onwards, storage at +30°C resulted in gradual, time-related reduction in the detection of mixed virus population at log10 VL 4.0 but not at log10 5.0. Proviral DNA and viral RNA were both stable for at least 52 weeks when stored at -20°C, compared to progressive RNA decay over time at +30°C. DBS storage conditions and duration had a significant effect on HIV-1 RNA amplification. Our results demonstrate that DBS storage at ambient temperature (+30°C) should not exceed two weeks, with long-term storage at -20°C or lower. PMID:26147689

  13. Stability of HIV-1 Nucleic Acids in Dried Blood Spot Samples for HIV-1 Drug Resistance Genotyping.

    PubMed

    Aitken, Susan C; Wallis, Carole L; Stevens, Wendy; de Wit, Tobias Rinke; Schuurman, Rob

    2015-01-01

    Dried blood spots (DBS) are an easy to collect sample-type that can stabilize biological material at ambient temperature for transport and storage, making them ideal for use in resource-limited settings (RLS). We investigated the effect of storage temperature and duration on ability to detect mixed HIV-1 viral RNA populations, and subsequently viral RNA populations in a background of proviral DNA. Part one of the study used DBS samples of whole blood spiked with specific quantities of HIV-1 subtype-B and -C RNA to study mixed virus population detection. Part two used DBS comprising of HIV-1 subtype-B proviral DNA containing U1 cells combined with HIV-1 subtype-C RNA to mimic HIV-1 infected clinical samples as a model system to study the relative stability of HIV-1 RNA and DNA in DBS. Prepared DBS were stored at -20 °C and +30 °C for periods of one day, one, two, and four weeks. Samples were genotyped to determine changes in the detection of mixtures in the sample over time. From two weeks onwards, storage at +30 °C resulted in gradual, time-related reduction in the detection of mixed virus population at log10 VL 4.0 but not at log10 5.0. Proviral DNA and viral RNA were both stable for at least 52 weeks when stored at -20 °C, compared to progressive RNA decay over time at +30 °C. DBS storage conditions and duration had a significant effect on HIV-1 RNA amplification. Our results demonstrate that DBS storage at ambient temperature (+30 °C) should not exceed two weeks, with long-term storage at -20 °C or lower. PMID:26147689

  14. Evaluation of the response of tritium-in-air instrumentation to HT in dry and humid conditions and to HTO vapor

    SciTech Connect

    Phillips, H.; Dean, J.; Privas, E.

    2015-03-15

    Nuclear plant operators (power generation, decommissioning and reprocessing operations) are required to monitor releases of tritium species for regulatory compliance and radiation protection purposes. Tritium monitoring is performed using tritium-in-air gas monitoring instrumentation based either on flow-through ion chambers or proportional counting systems. Tritium-in-air monitors are typically calibrated in dry conditions but in service may operate at elevated levels of relative humidity. The NPL (National Physical Laboratory) radioactive gas-in-air calibration system has been used to study the effect of humidity on the response to tritium of two tritium-in-air ion chamber based monitors and one proportional counting system which uses a P10/air gas mixture. The response of these instruments to HTO vapour has also been evaluated. In each case, instrument responses were obtained for HT in dry conditions (relative humidity (RH) about 2%), HT in 45% RH, and finally HTO at 45% RH. Instrumentation response to HT in humid conditions has been found to slightly exceed that in dry conditions. (authors)

  15. Solubility testing of actinides on breathing-zone and area air samples

    NASA Astrophysics Data System (ADS)

    Metzger, Robert Lawrence

    The solubility of inhaled radionuclides in the human lung is an important characteristic of the compounds needed to perform internal dosimetry assessments for exposed workers. A solubility testing method for uranium and several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALSsp°ler ) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of Usb3Osb8. This makes it possible to characterize solubility profiles in every section of operating facilities where airborne nuclides are found using common breathing zone air samples. The new method was evaluated by analyzing uranium compounds from two uranium mills whose product had been previously analyzed by in vitro solubility testing in the laboratory and in vivo solubility testing in rodents. The new technique compared well with the in vivo rodent solubility profiles. The method was then used to evaluate the solubility profiles in all process sections of an operating in situ uranium plant using breathing zone and area air samples collected during routine

  16. Effects of hot air and freeze drying methods on antioxidant activity, colour and some nutritional characteristics of strawberry tree (Arbutus unedo L) fruit.

    PubMed

    Orak, H H; Aktas, T; Yagar, H; İsbilir, S Selen; Ekinci, N; Sahin, F Hasturk

    2012-08-01

    Antioxidant activity, colour and some nutritional properties of hot air and freeze-dried strawberry tree (Arbutus unedo L.) fruits were investigated. Additionally, the effects of two pre-treatments, namely ethyl oleate and water blanching, were compared in terms of drying characteristics. For determination of antioxidant activities in ethanol extracts, two different analytical methods were used: 1,1-diphenyl-2-picrylhydrazyl scavenging activity and β-carotene bleaching activity. As a result, the ethyl oleate pre-treatment shortened the drying time by hot air method and gave a higher 1,1-diphenyl-2-picrylhydrazyl scavenging activity (82.16 ± 0.34%), total phenolic content (7.62 ± 1.09 µg GAE/g extract), ascorbic acid content (236.93 ± 20.14 mg/100 g), besides hydromethylfurfural was not observed. Freeze-dried fruits exhibited higher ascorbic acid content (368.63 ± 17.16 mg/100 g) than those fresh fruits (231.33 ± 19.51 mg/100 g) and nearly 1,1-diphenyl-2-picrylhydrazyl activity (93.52 ± 0.41 %) to fresh fruits (94.03 ± 1.18%). Colour characteristics, sugar content and mineral contents of fruits were significantly affected by pre-treatments and drying methods (p < 0.05). It is concluded that the drying of strawberry tree fruits should bring a valuable and attractive foodstuff to food industry due to the rich nutritional components, antioxidant activity and colour. Another conclusion from this study is that the freeze-drying is the best drying method to keep the nutritional value, antioxidant activity and sensory properties of fruits. PMID:22522307

  17. Laboratory validation and field verification of a new passive air monitoring badge for sampling ethylene oxide in air.

    PubMed

    Kring, E V; Damrell, D J; Basilio, A N; McGibney, P D; Douglas, J J; Henry, T J; Ansul, G R

    1984-10-01

    A new diffusion colorimetric air monitoring badge for sampling ethylene oxide is described. The Du Pont Pro-Tek C-70 badge has been laboratory validated over the range of 4-375 ppm-hours (0.5-47 ppm on an 8-hour TWA) using standard spectrophotometer readout in 1 centimeter (10 mm) cells. The lower range can be extended to 2 ppm-hours (0.25 ppm) by using 4 cm (40 mm) cells. The badge has an overall sampling and analytical method accuracy of +/- 13.5%. It meets NIOSH accuracy criteria and has a mean coefficient of variation CVT = 0.059. The badge has no temperature, pressure, relative humidity or face velocity effects over practical ranges. The response time is adequate to sample peak concentrations over short time periods. The badge may be used to determine ambient formaldehyde levels if suspected to be present along with ethylene oxide. Badges are shown to agree very well with the industry accepted and proposed ASTM pump/charcoal tube method in three extensive plant field tests. Badges were more precise than the charcoal tube/pump method in all field tests conducted. PMID:6496316

  18. High-Temperature Oxidation and Decarburization of 14.55 wt pct Cr-Cast Iron in Dry Air Atmosphere

    NASA Astrophysics Data System (ADS)

    Efremenko, V. G.; Chabak, Yu. G.; Lekatou, A.; Karantzalis, A. E.; Efremenko, A. V.

    2016-04-01

    The oxidation and decarburization behavior of 14.55 wt pct Cr-cast iron at 1273 K to 1423 K (1000 °C to 1150 °C) in a dry air atmosphere was studied. A gravimetric investigation showed that intensive oxidation of cast iron takes place at temperatures above 1273 K (1000 °C). It is found that oxidizing heating is accompanied by decarburization, which manifests itself in secondary and eutectic carbide dissolution. The volume fraction of carbides decreases with temperature and holding duration increasing. Decarburization results in the formation of a decarburized layer up to 4 mm in depth. A carbide-free layer in depth up to 100 μm appears in the free surface after 6 to 8 hours holding at 1373 K to 1423 K (1100 °C to 1150 °C). Preliminary activation energy calculations suggested that the eutectic carbide dissolution at the depths of 50 to 400 μm is controlled by carbon diffusion in austenite. The dissolution of eutectic carbides involves a capillarity-induced mechanism, which consists of formation and growth of capillary cavities inside carbides.

  19. Oxidation Behavior of a Pd43Cu27Ni10P20 Bulk Metallic Glass and Foam in Dry Air

    NASA Astrophysics Data System (ADS)

    Kai, W.; Ren, I. F.; Barnard, B.; Liaw, P. K.; Demetriou, M. D.; Johnson, W. L.

    2010-07-01

    The oxidation behavior of both Pd43Cu27Ni10P20 bulk metallic glass (Pd4-BMG) and its amorphous foam containing 45 pct porosity (Pd4-AF) was investigated over the temperature range of 343 K (70 °C) to 623 K (350 °C) in dry air. The results showed that virtually no oxidation occurred in the Pd4-BMG at T < 523 K (250 °C), revealing the alloy’s favorable oxidation resistance in this temperature range. In addition, the oxidation kinetics at T ≥ 523 K (250 °C) followed a parabolic-rate law, and the parabolic-rate constants ( k p values) generally increased with temperature. It was found that the oxidation k p values of the Pd4-AF are slightly lower than those of the Pd4-BMG, indicating that the porous structure contributes to improving the overall oxidation resistance. The scale formed on the alloys was composed exclusively of CuO at T ≥ 548 K (275 °C), whose thickness gradually increased with increasing temperature. In addition, the amorphous structure remained unchanged at T ≤ 548 K (275 °C), while a triplex-phase structure developed after the oxidation at higher temperatures, consisting of Pd2Ni2P, Cu3P, and Pd3P.

  20. STS-65 Commander Cabana and PLC Hieb take air sample at IML-2 Rack 7 NIZEMI

    NASA Technical Reports Server (NTRS)

    1994-01-01

    STS-65 Commander Robert D. Cabana (right) and Payload Commander (PLC) Richard J. Hieb take an air sample inside the International Microgravity Laboratory 2 (IML-2) spacelab science module. The two crewmembers are in front of Rack 7 which contains the large isothermal furnace (LIF) and slow rotating centrifuge microscope (NIZEMI). The photo was among the first group released by NASA following the two-week IML-2 mission aboard the Space Shuttle Columbia, Orbiter Vehicle (OV) 102.

  1. Organic toxicants in air and precipitation samples from the Lake Michigan area

    SciTech Connect

    Harlin, K.S.; Sweet, C.W.; Gatz, D.F.

    1995-12-31

    Measurements of PCBs, organochlorine insecticides, PAHs, and atrazine were made in air and precipitation samples collected at regionally-representative locations near Lake Michigan from 1992-1995. The purpose of these measurements was to provide information needed to estimate the atmospheric deposition of organic toxicants to Lake Michigan. Twenty-four hour samples of airborne particles and vapor were collected at 12-day intervals on quartz fiber filters and XAD-2 resin vapor traps using modified high volume sampleers. Twenty-eight day precipitation samples were collected using wet-only samplers with stainless steel sampling surfaces and heated enclosure containing an XAD-2 resin adsorption column. Samples were Soxhlet extracted for 24 hours with hexane:acetone (1:1), and concentrated by rotary evaporation. Interferences were removed and the samples separated into analyte groups by silica gel chromatography. Four fractions were collected for GC-ECD and GC-Ion Trap MS analyses. Ten pesticides, 101 PCB congeners, 18 PAHs, and atrazine were measured in all samples. Quality assurance was maintained by including field duplicate samples, field blanks, alboratory matrix spikes, laboratory matrix blanks, and laboratory surrogate spikes in the sampling/analytical protocols. Preliminary results from urban and remote sites show geographical variations in the concentrations of some toxicants due to contributions from local sources. For all sites the total PCB levels are higher in the vapor phase than the particulate phase and show strong seasonal variations. Seasonal variations were also observed for several pesticides.

  2. Isotopic air sampling in a tallgrass prairie to partition net ecosystem CO2 exchange

    NASA Astrophysics Data System (ADS)

    Lai, Chun-Ta; Schauer, Andrew J.; Owensby, Clenton; Ham, Jay M.; Ehleringer, James R.

    2003-09-01

    Stable isotope ratios of various ecosystem components and net ecosystem exchange (NEE) CO2 fluxes were measured in a C3-C4 mixture tallgrass prairie near Manhattan, Kansas. The July 2002 study period was chosen because of contrasting soil moisture contents, which allowed us to address the effects of drought on photosynthetic CO2 uptake and isotopic discrimination. Significantly higher NEE fluxes were observed for both daytime uptake and nighttime respiration during well-watered conditions when compared to a drought period. Given these differences, we investigated two carbon-flux partitioning questions: (1) What proportions of NEE were contributed by C3 versus C4 species? (2) What proportions of NEE fluxes resulted from canopy assimilation versus ecosystem respiration? To evaluate these questions, air samples were collected every 2 hours during daytime for 3 consecutive days at the same height as the eddy covariance system. These air samples were analyzed for both carbon isotope ratios and CO2 concentrations to establish an empirical relationship for isoflux calculations. An automated air sampling system was used to collect nighttime air samples to estimate the carbon isotope ratios of ecosystem respiration (δR) at weekly intervals for the entire growing season. Models of C3 and C4 photosynthesis were employed to estimate bulk canopy intercellular CO2 concentration in order to calculate photosynthetic discrimination against 13C. Our isotope/NEE results showed that for this grassland, C4 vegetation contributed ˜80% of the NEE fluxes during the drought period and later ˜100% of the NEE fluxes in response to an impulse of intense precipitation. For the entire growing season, the C4 contribution ranged from ˜68% early in the spring to nearly 100% in the late summer. Using an isotopic approach, the calculated partitioned respiratory fluxes were slightly greater than chamber-measured estimates during midday under well-watered conditions. In addition, time series

  3. Microbial Air and Surface Monitoring Results from International Space Station Samples

    NASA Technical Reports Server (NTRS)

    Ott, C. Mark; Bruce, Rebekah J.; Castro, Victoria A.; Novikova, Natalia D.; Pierson, D. L.

    2005-01-01

    Over the course of long-duration spaceflight, spacecraft develop a microbial ecology that directly interacts with the crew of the vehicle. While most microorganisms are harmless or beneficial to the inhabitants of the vehicle, the presence of medically significant organisms appearing in this semi-closed environment could adversely affect crew health and performance. The risk of exposure of the crew to medically significant organisms during a mission is estimated using information gathered during nominal and contingency environmental monitoring. Analysis of the air and surface microbiota in the habitable compartments of the International Space Station (ISS) over the last four years indicate a high presence of Staphylococcus species reflecting the human inhabitants of the vehicle. Generally, air and surface microbial concentrations are below system design specifications, suggesting a lower risk of contact infection or biodegradation. An evaluation of sample frequency indicates a decrease in the identification of new species, suggesting a lower potential for unknown microorganisms to be identified. However, the opportunistic pathogen, Staphylococcus aureus, has been identified in 3 of the last 5 air samples and 5 of the last 9 surface samples. In addition, 47% of the coagulase negative Staphylococcus species that were isolated from the crew, ISS, and its hardware were found to be methicillin resistance. In combination, these observations suggest the potential of methicillin resistant infectious agents over time.

  4. High sensitivity gamma spectrometry of air samples near SRS during 1985-1995

    SciTech Connect

    Winn, W.G.; Cadieux, J.R.

    1997-07-01

    High sensitivity gamma analysis of off-site air samples near the Savannah River Site (SRS) is achieved by collecting large volume air samples for analysis by ultra-low-level gamma spectrometry. A review of the 1985-1995 measurements has highlighted local and distant releases of man-made radionuclides, along with cosmogenic radionuclides which correlate with both solar and seasonal phenomena. Measurements typically involve 2-day air collection of a 70,000 m{sup 3} sample on a 51 cm x 51 cm cellulose filter using a high-capacity pump. Short-lived radon background activity is allowed to decay a few days, and then the filter is configured into a smaller calibrated volume and counted 1-3 days on a 30 percent-efficient HPGe in the Ultra-Low-Level Counting Facility. Representative detection limits for this method are shown in Table 1, and even lower limits are achievable by counting on the low-background 160 percent-efficient HPGe of the Underground Counting Facility.

  5. Technical assessment of TRUSAF for compliance with work place air sampling. Revision 1

    SciTech Connect

    Butler, J.D.

    1995-01-23

    The purpose of this Technical Work Document is to satisfy WHC-CM-1-6, the ``WHC Radiological Control Manual.`` This first revision of the original Supporting Document covers the period from January 1, 1994 to December 31, 1994. WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ``Hanford Site Radiological Control Manual`` and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. this document also provides an evaluation of the compliance of the TRUSAF workplace air sampling program to the criteria, standards, and requirements and documents. Where necessary, it also indicates changes needed to bring specific locations into compliance.

  6. Technical assessment of workplace air sampling requirements at tank farm facilities. Revision 1

    SciTech Connect

    Olsen, P.A.

    1994-09-21

    WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). It was written to implement DOE N 5480.6 ``US Department of Energy Radiological Control Manual`` as it applies to programs at Hanford which are now overseen by WHC. As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ``Hanford Site Radiological Control Manual`` and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. This document also provides an evaluation of the compliance of Tank Farms` workplace air sampling program to the criteria, standards, and requirements and documents compliance with the requirements where appropriate. Where necessary, it also indicates changes needed to bring specific locations into compliance.

  7. Determination of methyl bromide in air samples by headspace gas chromatography

    SciTech Connect

    Woodrow, J.E.; McChesney, M.M.; Seiber, J.N.

    1988-03-01

    Methyl bromide is extensively used in agriculture (4 x 10/sup 6/ kg for 1985 in California alone as a fumigant to control nematodes, weeds, and fungi in soil and insect pests in harvested grains and nuts. Given its low boiling point (3.8/sup 0/C) and high vapor pressure (approx. 1400 Torr at 20/sup 0/C), methyl bromide will readily diffuse if not rigorously contained. Methods for determining methyl bromide and other halocarbons in air vary widely. A common practice is to trap the material from air on an adsorbent, such as polymeric resins, followed by thermal desorption either directly into the analytical instrumentation or after intermediary cryofocusing. While in some cases analytical detection limits were reasonable (parts per million range), many of the published methods were labor intensive and required special handling techniques that precluded high sample throughput. They describe here a method for the sampling and analysis of airborne methyl bromide that was designed to handle large numbers of samples through automating some critical steps of the analysis. The result was a method that allowed around-the-clock operation with a minimum of operator attention. Furthermore, the method was not specific to methyl bromide and could be used to determine other halocarbons in air.

  8. The use of Whatman-41 filters for high volume air sampling

    NASA Technical Reports Server (NTRS)

    Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.

    1975-01-01

    The feasibility of using W41 filter media on a routine TSP high-volume monitoring network was determined by comparison with glass fiber (GF) filtering. Results indicate that suspended particulate samples from GF filters averaged slightly, but not significantly, higher than those from Whatman-41 filters. Some extra handling procedures were required to avoid errors due to the hygroscopic nature of W41 filters; these added procedures are not overly burdensome, however, and they allow the performance of analytical work, thus extending the capabilities of high-volume sampling. It was demonstrated that W41 filters are practical for air quality monitoring and elemental analysis in environments similar to Cleveland's.

  9. A new analysis system for whole air sampling: description and results from 2013 SENEX

    NASA Astrophysics Data System (ADS)

    Lerner, B. M.; Gilman, J.; Dumas, M.; Hughes, D.; Jaksich, A.; Hatch, C. D.; Graus, M.; Warneke, C.; Apel, E. C.; Hornbrook, R. S.; Holloway, J. S.; De Gouw, J. A.

    2014-12-01

    Accurate measurement of volatile organic compounds (VOCs) in the troposphere is critical for the understanding of emissions and physical and chemical processes that can impact both air quality and climate. Airborne VOC measurements have proven especially challenging due to the requirement of both high sensitivity (pptv) and short sample collection times (≤15 s) to maximize spatial resolution and sampling frequency for targeted plume analysis. The use of stainless steel canisters to collect whole air samples (WAS) for post-flight analysis has been pioneered by the groups of D. Blake and E. Atlas [Blake et al., 1992; Atlas et al., 1993]. For the 2013 Southeast Nexus Study (SENEX), the NOAA ESRL CSD laboratory undertook WAS measurements for the first time. This required the construction of three new, highly-automated, and field-portable instruments designed to sample, analyze, and clean the canisters for re-use. Analysis was performed with a new custom-built gas chromatograph-mass spectrometer system. The instrument pre-concentrates analyte cryostatically into two parallel traps by means of a Stirling engine, a novel technique which obviates the need for liquid nitrogen to reach trapping temperatures of -175C. Here we present an evaluation of the retrieval of target VOC species from WAS canisters. We discuss the effects of humidity and sample age on the analyte, particularly upon C8+ alkane and aromatic species and biogenic species. Finally, we present results from several research flights during SENEX that targeted emissions from oil/natural gas production.

  10. Measurement of the Tracer Gradient and Sampling System Bias of the Hot Fuel Examination Facility Stack Air Monitoring System

    SciTech Connect

    Glissmeyer, John A.; Flaherty, Julia E.

    2011-07-20

    This report describes tracer gas uniformity and bias measurements made in the exhaust air discharge of the Hot Fuel Examination Facility at Idaho National Laboratory. The measurements were a follow-up on earlier measurements which indicated a lack of mixing of the two ventilation streams being discharged via a common stack. The lack of mixing is detrimental to the accuracy of air emission measurements. The lack of mixing was confirmed in these new measurements. The air sampling probe was found to be out of alignment and that was corrected. The suspected sampling bias in the air sample stream was disproved.

  11. Effect of dry-air chilling on sensory descriptive profiles of cooked broiler breast meat deboned four hours after the initiation of chilling.

    PubMed

    Zhuang, H; Savage, E M; Smith, D P; Berrang, M E

    2009-06-01

    The objective of this study was to evaluate the effect of a dry air-chilling (AC) method on sensory texture and flavor descriptive profiles of broiler pectoralis major (fillet) and pectoralis minor (tender). The profiles of the muscles immersion-chilled and deboned at the same postmortem time and the profiles of the muscles hot-boned (or no chill) were used for the comparison. A total of 108 eviscerated carcasses (6-wk-old broilers) were obtained from a commercial processing line before the chillers. Carcasses were transported to a laboratory facility where they were either i) chilled by a dry AC method (0.7 degrees C, 150 min in a cold room), ii) chilled by immersion chilling (IC; 0.3 degrees C, 50 min in a chiller), or iii) not chilled (9 birds per treatment per replication). Both IC and AC fillets and tenders were removed from the bone at 4 h after the initiation of chilling (approximately 4.75 h postmortem) in a processing area (18 degrees C). The no-chill muscles were removed immediately upon arrival. The sensory properties (21 attributes) of cooked broiler breast meat were evaluated by trained panelists using 0- to 15-point universal intensity scales. The average intensity scores of the 9 flavor attributes analyzed ranged from 0.9 to 4.0. Regardless of breast muscle type, there were no significant differences in sensory flavor descriptive profiles between the 3 treatments. The average intensity scores of the 12 texture attributes ranged from 1.5 to 7.5 and there were no significant differences between the AC and IC samples. The average intensity scores of the texture attributes, cohesiveness, hardness, cohesiveness of mass, rate of breakdown, and chewiness of the no chill fillets and tenders were significantly higher than those of either of the chilled samples. These results demonstrate that chicken breast meat from AC retains sensory flavor profile characteristics but AC results in sensory texture profile differences when compared with no-chill meat. Sensory

  12. Development of a non-thermal accelerated pulsed UV photolysis assisted digestion method for fresh and dried food samples

    NASA Astrophysics Data System (ADS)

    Solís, C.; Lagunas-Solar, M. C.; Perley, B. P.; Piña, C.; Aguilar, L. F.; Flocchini, R. G.

    2002-04-01

    A simple, fast digestion procedure for fresh and dried foods, using high-power pulsed UV photolysis in the presence of hydrogen peroxide, is being developed. The homogenized food samples were mixed with H 2O 2 or with a mixture of H 2O 2 and HNO 3, and irradiated for short times with a 248-nm UV excimer laser. After centrifugation, a clear, colorless solution was obtained and aliquots were deposited on Teflon filters for XRF and/or PIXE analyses. Standard reference materials (NIST Peach Leaves; Typical Diet) were also analyzed to compare recoveries and detection limits. Improvements in detection limits were observed, but a few trace elements (<1 ppm) were not reproducibly detected (Fe, Sr). This method proved to be practical for the accelerated digestion of food samples and preparing analytes in short-time intervals. In combination with PIXE and XRF, it allows high-sensitivity multi-elemental analyses for screening the nutritional elements and for food safety purposes regarding the potential presence of toxic elements. Further development to optimize and validate this procedure for a broader range of analytes is in progress.

  13. Sampling and analysis of trace-organic constituents in ambient and workplace air at coal-conversion facilities

    SciTech Connect

    Flotard, R D

    1980-07-01

    A review of the recent literature reveals that current sampling procedures involve the use of glass fiber filters for particulate-sorbed organics and sorbent resins such as Tenax GC and XAD-2 for vapor-phase organics. Ultra trace-organic analysis of air pollutants or particulates may require the collection of a large (1000 to 3000 m/sup 3/) sample by a high volume air sampler. Personal air sampling requires a smaller (approx. = 0.5 m/sup 3/) and a portable collection apparatus. Trapped organic chemicals are recovered by solvent extraction or thermal desorption of the collector. Recovered organics are separated by using liquid chromatography or gas chromatography and are identified by ultraviolet or fluorescence spectroscopy, gas chromatography, or mass spectrometry. For quantification, standards are added to the air stream during sampling or to the filter or resin following sampling. Analysis of the requirement for air sampling in and around coal conversion plants, coupled with the findings of the literature review, indicates that a combined particulate-filter and solvent-extractable-resin sampling unit should be used to collect both particulate-sorbed organics and vapor-phase organics from workplace or ambient plant air. Such a sampler was developed for stationary, moderate-to-high-volume air sampling. Descriptions of the sampler are provided together with sampling efficiency information and recommendations for a sampling procedure.

  14. Hygrothermal performance of EIFS-clad walls: Effect of vapor diffusion and air leakage on the drying of construction moisture [Exterior Insulation and Finish Systems

    SciTech Connect

    Karagiozis, A.N.; Salonvaara, M.H.

    1999-07-01

    Hydrothermal performance describes the response of the material layers that make up the wall to thermal and moisture loads. Modeling can be applied to determine the drying and wetting potential of walls with various initial construction moisture loads and to test alternative innovations. This paper investigates the drying performance of a particular barrier EIFS clad wall as a function of vapor diffusion control with a specific air leakage path. This investigation was conducted with constant interior temperature and relative humidity. The LATENITE model, developed at NRD, is employed in the investigation. This advanced hydrothermal model can incorporate system and sub-system performances by introducing simulated defects and wall system details derived from laboratory and field measurements. Moisture loads available to the EIFS structure originating either from the interior, the exterior or from initial construction moisture can be included. In this paper the authors present a study to determine the drying potential of a barrier EIFS clad wall for the climate of Wilmington, NC. This climate is characterized by the ASHRAE Handbook of Fundamentals as being mixed. The effect of drying and wetting by airflow was investigated by introducing airflow paths. Hydrothermal performance with three different vapor diffusion control strategies and two air leakage conditions was simulated for a period of one year. Initial oriented strand board (OSB) moisture content was assumed to be very high. The influence of rain water, solar radiation and air movement within the cavity was included in the analysis.

  15. Effects of nozzle type atmospheric dry air plasma on L929 fibroblast cells hybrid poly (ε-caprolactone)/chitosan/poly (ε-caprolactone) scaffolds interactions.

    PubMed

    Ozkan, Ozan; Turkoglu Sasmazel, Hilal

    2016-08-01

    In the study presented here, in order to improve the surface functionality and topography of poly (ε-caprolactone) (PCL)/chitosan/PCL hybrid tissue scaffolds fabricated layer by layer with electrospinning technique, an atmospheric pressure nozzle type plasma surface modification was utilized. The optimization of the plasma process parameters was carried out by monitoring the changes in surface hydrophilicity by using contact angle measurements. SEM, AFM and XPS analyses were utilized to observe the changes in topographical and chemical properties of the modified surfaces. The results showed that applied plasma modification altered the nanotopography and the functionality of the surfaces of the scaffolds. The modification applied for 9 min from a distance of 17 cm was found to provide the possible contact angle value (75.163±0.083) closest to the target value which is the value of tissue culture polystyrene (TCPS) petri dishes (∼49.7°), compared to the unmodified samples (84.46±3.86). In vitro cell culture was carried out by L929 mouse fibroblast cell line in order to examine the effects of plasma surface modification on cell-material interactions. Standard MTT assay showed improved cell viability on/within modified scaffolds confirmed with the observations of the cell attachment and the morphology by means of SEM, fluorescence and confocal imaging. The experiments performed in the study proved the enhanced biocompatibility of the nozzle type dry air plasma modified scaffolds. PMID:26906227

  16. Airborne Detection and Quantification of Swine Influenza A Virus in Air Samples Collected Inside, Outside and Downwind from Swine Barns

    PubMed Central

    Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164

  17. Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air Part 1: Sorbent-based air monitoring options.

    PubMed

    Woolfenden, Elizabeth

    2010-04-16

    Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Target compounds range in volatility from acetylene and freons to phthalates and PCBs and include apolar, polar and reactive species. Airborne vapour concentrations will vary depending on the nature of the location, nearby pollution sources, weather conditions, etc. Levels can range from low percent concentrations in stack and vent emissions to low part per trillion (ppt) levels in ultra-clean outdoor locations. Hundreds, even thousands of different compounds may be present in any given atmosphere. GC is commonly used in combination with mass spectrometry (MS) detection especially for environmental monitoring or for screening uncharacterised workplace atmospheres. Given the complexity and variability of organic vapours in air, no one sampling approach suits every monitoring scenario. A variety of different sampling strategies and sorbent media have been developed to address specific applications. Key sorbent-based examples include: active (pumped) sampling onto tubes packed with one or more sorbents held at ambient temperature; diffusive (passive) sampling onto sorbent tubes/cartridges; on-line sampling of air/gas streams into cooled sorbent traps; and transfer of air samples from containers (canisters, Tedlar) bags, etc.) into cooled sorbent focusing traps. Whichever sampling approach is selected, subsequent analysis almost always involves either solvent extraction or thermal desorption (TD) prior to GC(/MS) analysis. The overall performance of the air monitoring method will depend heavily on appropriate selection of key sampling and analytical parameters. This comprehensive review of air monitoring using sorbent tubes/traps is divided into 2 parts. (1) Sorbent-based air sampling option. (2) Sorbent selection and other aspects of optimizing sorbent-based air monitoring methods. The paper presents

  18. Quantification of rifapentine, a potent antituberculosis drug, from dried blood spot samples using liquid chromatographic-tandem mass spectrometric analysis.

    PubMed

    Parsons, Teresa L; Marzinke, Mark A; Hoang, Thuy; Bliven-Sizemore, Erin; Weiner, Marc; Mac Kenzie, William R; Dorman, Susan E; Dooley, Kelly E

    2014-11-01

    The quantification of antituberculosis drug concentrations in multinational trials currently requires the collection of modest blood volumes, centrifugation, aliquoting of plasma, freezing, and keeping samples frozen during shipping. We prospectively enrolled healthy individuals into the Tuberculosis Trials Consortium Study 29B, a phase I dose escalation study of rifapentine, a rifamycin under evaluation in tuberculosis treatment trials. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying rifapentine in whole blood on dried blood spots (DBS) to facilitate pharmacokinetic/pharmacodynamic analyses in clinical trials. Paired plasma and whole-blood samples were collected by venipuncture, and whole blood was spotted on Whatman protein saver 903 cards. The methods were optimized for plasma and then validated for DBS. The analytical measuring range for quantification of rifapentine and its metabolite was 50 to 80,000 ng/ml in whole-blood DBS. The analyte was stable on the cards for 11 weeks with a desiccant at room temperature and protected from light. The method concordance for paired plasma and whole-blood DBS samples was determined after correcting for participant hematocrit or population-based estimates of bias from Bland-Altman plots. The application of either correction factor resulted in acceptable correlation between plasma and whole-blood DBS (Passing-Bablok regression corrected for hematocrit; y = 0.98x + 356). Concentrations of rifapentine may be determined from whole-blood DBS collected via venipuncture after normalization in order to account for the dilutional effects of red blood cells. Additional studies are focused on the application of this methodology to capillary blood collected by finger stick. The simplicity of processing, storage, shipping, and low blood volume makes whole-blood DBS attractive for rifapentine pharmacokinetic evaluations, especially in international and pediatric trials. PMID:25182637

  19. Quantification of Rifapentine, a Potent Antituberculosis Drug, from Dried Blood Spot Samples Using Liquid Chromatographic-Tandem Mass Spectrometric Analysis

    PubMed Central

    Parsons, Teresa L.; Marzinke, Mark A.; Hoang, Thuy; Bliven-Sizemore, Erin; Weiner, Marc; Mac Kenzie, William R.; Dorman, Susan E.

    2014-01-01

    The quantification of antituberculosis drug concentrations in multinational trials currently requires the collection of modest blood volumes, centrifugation, aliquoting of plasma, freezing, and keeping samples frozen during shipping. We prospectively enrolled healthy individuals into the Tuberculosis Trials Consortium Study 29B, a phase I dose escalation study of rifapentine, a rifamycin under evaluation in tuberculosis treatment trials. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying rifapentine in whole blood on dried blood spots (DBS) to facilitate pharmacokinetic/pharmacodynamic analyses in clinical trials. Paired plasma and whole-blood samples were collected by venipuncture, and whole blood was spotted on Whatman protein saver 903 cards. The methods were optimized for plasma and then validated for DBS. The analytical measuring range for quantification of rifapentine and its metabolite was 50 to 80,000 ng/ml in whole-blood DBS. The analyte was stable on the cards for 11 weeks with a desiccant at room temperature and protected from light. The method concordance for paired plasma and whole-blood DBS samples was determined after correcting for participant hematocrit or population-based estimates of bias from Bland-Altman plots. The application of either correction factor resulted in acceptable correlation between plasma and whole-blood DBS (Passing-Bablok regression corrected for hematocrit; y = 0.98x + 356). Concentrations of rifapentine may be determined from whole-blood DBS collected via venipuncture after normalization in order to account for the dilutional effects of red blood cells. Additional studies are focused on the application of this methodology to capillary blood collected by finger stick. The simplicity of processing, storage, shipping, and low blood volume makes whole-blood DBS attractive for rifapentine pharmacokinetic evaluations, especially in international and pediatric trials. PMID:25182637

  20. Sampling artifacts in active air sampling of semivolatile organic contaminants: Comparing theoretical and measured artifacts and evaluating implications for monitoring networks.

    PubMed

    Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Klánová, Jana

    2016-10-01

    The effects of sampling artifacts are often not fully considered in the design of air monitoring with active air samplers. Semivolatile organic contaminants (SVOCs) are particularly vulnerable to a range of sampling artifacts because of their wide range of gas-particle partitioning and degradation rates, and these can lead to erroneous measurements of air concentrations and a lack of comparability between sites with different environmental and sampling conditions. This study used specially adapted filter-sorbent sampling trains in three types of active air samplers to investigate breakthrough of SVOCs, and the possibility of other sampling artifacts. Breakthrough volumes were experimentally determined for a range of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polybrominated diphenyl ethers (PBDEs) in sampling volumes from 300 to 10,000 m(3), and sampling durations of 1-7 days. In parallel, breakthrough was estimated based on theoretical sorbent-vapor pressure relationships. The comparison of measured and theoretical determinations of breakthrough demonstrated good agreement between experimental and estimated breakthrough volumes, and showed that theoretical breakthrough estimates should be used when developing air monitoring protocols. Significant breakthrough in active air samplers occurred for compounds with vapor pressure >0.5 Pa at volumes <700 m(3). Sample volumes between 700 and 10,000 m(3) may lead to breakthrough for compounds with vapor pressures between 0.005 and 0.5 Pa. Breakthrough is largely driven by sample volume and compound volatility (therefore indirectly by temperature) and is independent of sampler type. The presence of significant breakthrough at "typical" sampling conditions is relevant for air monitoring networks, and may lead to under-reporting of more volatile SVOCs. PMID:26743995

  1. Nonuniform air flow in inlets: the effect on filter deposits in the fiber sampling cassette.

    PubMed

    Baron, P A; Chen, C C; Hemenway, D R; O'Shaughnessy, P

    1994-08-01

    Smoke stream studies were combined with a new technique for visualizing a filter deposit from samples used to monitor asbestos or other fibers. Results clearly show the effect of secondary flow vortices within the sampler under anisoaxial sampling conditions. The vortices observed at low wind velocities occur when the inlet axis is situated at angles between 45 degrees and 180 degrees to the motion of the surrounding air. It is demonstrated that the vortices can create a complex nonuniform pattern in the filter deposit, especially when combined with particle settling or electrostatic interactions between the particles and the sampler. Inertial effects also may play a role in the deposit nonuniformity, as well as causing deposition on the cowl surfaces. Changes in the sampler, such as its placement, may reduce these biases. The effects noted are not likely to occur in all sampling situations, but may explain some reports of high variability on asbestos fiber filter samples. The flow patterns observed in this study are applicable to straight, thin-walled inlets. Although only compact particles were used, the air flow patterns and forces involved will have similar effects on fibers of the same aerodynamic diameter. PMID:7942509

  2. Greenhouse gas analysis of air samples collected onboard the CARIBIC passenger aircraft

    NASA Astrophysics Data System (ADS)

    Schuck, T. J.; Brenninkmeijer, C. A. M.; Slemr, F.; Xueref-Remy, I.; Zahn, A.

    2009-03-01

    CARIBIC (Civil Aircraft for the Regular Investigation of the Atmosphere Based on an Instrument Container) is a long-term atmospheric measurement program based on the use of a comprehensive scientific instrument package aboard a passenger aircraft. In addition to real time measurements, whole air sampling is performed regularly at cruising altitude in the upper troposphere and the extra-tropical UT/LS region. Air samples are analysed for greenhouse gases, NMHCs, halocarbons, and isotopic composition. The routinely performed greenhouse gas analysis comprises gas chromatography measurements of CO2, CH4, N2O and SF6. The sampling procedure, the GC system used for greenhouse gas analysis and its performance are described. Comparisons with other laboratories have shown good agreement of results as has a comparison with results from a CO2 in-situ analyser that is also part of the CARIBIC instrumentation. The timeseries of CO2 obtained from the collection of 684 samples at latitudes between 30° N and 56° N on 21 roundtrips out of Germany to different destinations in Asia between November 2005 and October 2008 is shown. A timeshift in the seasonal cyle of about one month was observed between the upper troposphere and the tropopause region. For two sets of return flights from Germany to the Philippines the relations between the four greenhouse gases CO2, CH4, N2O and SF6 are discussed in more detail. Distinct seasonal changes in the correlation between CH4 and CO2 are observed.

  3. Biomimetic air sampling for detection of low concentrations of molecules and bioagents : LDRD 52744 final report.

    SciTech Connect

    Hughes, Robert Clark

    2003-12-01

    Present methods of air sampling for low concentrations of chemicals like explosives and bioagents involve noisy and power hungry collectors with mechanical parts for moving large volumes of air. However there are biological systems that are capable of detecting very low concentrations of molecules with no mechanical moving parts. An example is the silkworm moth antenna which is a highly branched structure where each of 100 branches contains about 200 sensory 'hairs' which have dimensions of 2 microns wide by 100 microns long. The hairs contain about 3000 pores which is where the gas phase molecules enter the aqueous (lymph) phase for detection. Simulations of diffusion of molecules indicate that this 'forest' of hairs is 'designed' to maximize the extraction of the vapor phase molecules. Since typical molecules lose about 4 decades in diffusion constant upon entering the liquid phase, it is important to allow air diffusion to bring the molecule as close to the 'sensor' as possible. The moth acts on concentrations as low as 1000 molecules per cubic cm. (one part in 1e16). A 3-D collection system of these dimensions could be fabricated by micromachining techniques available at Sandia. This LDRD addresses the issues involved with extracting molecules from air onto micromachined structures and then delivering those molecules to microsensors for detection.

  4. Urban air quality assessment using monitoring data of fractionized aerosol samples, chemometrics and meteorological conditions.

    PubMed

    Yotova, Galina I; Tsitouridou, Roxani; Tsakovski, Stefan L; Simeonov, Vasil D

    2016-01-01

    The present article deals with assessment of urban air by using monitoring data for 10 different aerosol fractions (0.015-16 μm) collected at a typical urban site in City of Thessaloniki, Greece. The data set was subject to multivariate statistical analysis (cluster analysis and principal components analysis) and, additionally, to HYSPLIT back trajectory modeling in order to assess in a better way the impact of the weather conditions on the pollution sources identified. A specific element of the study is the effort to clarify the role of outliers in the data set. The reason for the appearance of outliers is strongly related to the atmospheric condition on the particular sampling days leading to enhanced concentration of pollutants (secondary emissions, sea sprays, road and soil dust, combustion processes) especially for ultra fine and coarse particles. It is also shown that three major sources affect the urban air quality of the location studied-sea sprays, mineral dust and anthropogenic influences (agricultural activity, combustion processes, and industrial sources). The level of impact is related to certain extent to the aerosol fraction size. The assessment of the meteorological conditions leads to defining of four downwind patterns affecting the air quality (Pelagic, Western and Central Europe, Eastern and Northeastern Europe and Africa and Southern Europe). Thus, the present study offers a complete urban air assessment taking into account the weather conditions, pollution sources and aerosol fractioning. PMID:26942452

  5. Air-dried cells from the anhydrobiotic insect, Polypedilum vanderplanki, can survive long term preservation at room temperature and retain proliferation potential after rehydration.

    PubMed

    Watanabe, Kazuyo; Imanishi, Shigeo; Akiduki, Gaku; Cornette, Richard; Okuda, Takashi

    2016-08-01

    Pv11, a cell line derived from the anhydrobiotic insect, Polypedilum vanderplanki, was preserved in a dry form (only 6% residual moisture) at room temperature for up to 251 days and restarted proliferating after rehydration. A previous study already reported survival of Pv11 cells after desiccation, but without subsequent proliferation. Here, the protocol was improved to increase survival and achieve proliferation of Pv11 cells after dry storage. The method basically included preincubation, desiccation and rehydration processes and each step was investigated. So far, preincubation in a 600 mM trehalose solution for 48 h before dehydration was the most favourable preconditioning to achieve successful dry preservation of Pv11 cells, allowing about 16% of survival after rehydration and subsequent cell proliferation. Although the simple air-dry method established for Pv11 cells here was not applicable for successful dry-preservation of other insect cell lines, Pv11 is the first dry-preservable animal cell line and will surely contribute not only to basic but also applied sciences. PMID:27207249

  6. Quantifying water and air redistribution in heterogeneous sand sample by neutron imaging

    NASA Astrophysics Data System (ADS)

    Šácha, Jan; Sobotková, Martina; Jelínková, Vladimíra; Sněhota, Michal; Vontobel, Peter; Hovind, Jan

    2014-05-01

    Significant temporal variation of quasi saturated hydraulic conductivity (Kqs) has been observed to date in number of infiltration experiments conducted mainly on heterogeneous soil of Cambisol. The change of quasi-saturated hydraulic conductivity cannot be precisely described by existing models. The Kqs variations has been recently attributed to a changing distribution of the entrapped air and water within the sample. It is expected that air is moved to the preferential pathway and acts as a barrier there. To support this assumption a ponded infiltration experiment was conducted on a soil sample packed into the quartz glass column of inner diameter of 34 mm. The sample composition represents simplified heterogeneity of the natural soil but also allow the easy quantitative water content determination in individual subdomains of the sample. The matrix formed by a fine sand was surrounded with regions of coarse sand representing preferential flow pathways. The Kqs was determined from the known hydraulic gradient and measured volume flux. The experiment was monitored by neutron radiography. Volume of water in the sample calculated from neutron projections matched very well with actually infiltrated volume in the sample during first 40 second after beginning of infiltration. From the acquired radiographic images the 3D tomography images were reconstructed to obtain the spatial distribution of the water content within the sample. Difference between water volume calculated from radiography and tomography images was no more than 5%. While the total amount of water determined by NR within the sample during the quasi steady state flow remains practically constant (27.9 cm3 at the beginning and 28.6 cm3 on the end of infiltration) the water content in the coarse fraction decreases (from 0.333 to 0.324) and the water content in the fine fraction increases (from 0.414 to 0.436) in 5 hours. Similarly to previous experiments performed on natural Cambisols, the results support

  7. Glyphosate–rich air samples induce IL–33, TSLP and generate IL–13 dependent airway inflammation

    PubMed Central

    Kumar, Sudhir; Khodoun, Marat; Kettleson, Eric M.; McKnight, Christopher; Reponen, Tiina; Grinshpun, Sergey A.; Adhikari, Atin

    2014-01-01

    Several low weight molecules have often been implicated in the induction of occupational asthma. Glyphosate, a small molecule herbicide, is widely used in the world. There is a controversy regarding a role of glyphosate in developing asthma and rhinitis among farmers, the mechanism of which is unexplored. The aim of this study was to explore the mechanisms of glyphosate induced pulmonary pathology by utilizing murine models and real environmental samples. C57BL/6, TLR4−/−, and IL-13−/− mice inhaled extracts of glyphosate-rich air samples collected on farms during spraying of herbicides or inhaled different doses of glyphosate and ovalbumin. The cellular response, humoral response, and lung function of exposed mice were evaluated. Exposure to glyphosate-rich air samples as well as glyphosate alone to the lungs increased: eosinophil and neutrophil counts, mast cell degranulation, and production of IL-33, TSLP, IL-13, and IL-5. In contrast, in vivo systemic IL-4 production was not increased. Co-administration of ovalbumin with glyphosate did not substantially change the inflammatory immune response. However, IL-13-deficiency resulted in diminished inflammatory response but did not have a significant effect on airway resistance upon methacholine challenge after 7 or 21 days of glyphosate exposure. Glyphosate-rich farm air samples as well as glyphosate alone were found to induce pulmonary IL-13-dependent inflammation and promote Th2 type cytokines, but not IL-4 for glyphosate alone. This study, for the first time, provides evidence for the mechanism of glyphosate-induced occupational lung disease. PMID:25172162

  8. Sampling size in the verification of manufactured-supplied air kerma strengths

    SciTech Connect

    Ramos, Luis Isaac; Martinez Monge, Rafael

    2005-11-15

    Quality control mandate that the air kerma strengths (S{sub K}) of permanent seeds be verified, this is usually done by statistics inferred from 10% of the seeds. The goal of this paper is to proposed a new sampling method in which the number of seeds to be measured will be set beforehand according to an a priori statistical level of uncertainty. The results are based on the assumption that the S{sub K} has a normal distribution. To demonstrate this, the S{sub K} of each of the seeds measured was corrected to ensure that the average S{sub K} of its sample remained the same. In this process 2030 results were collected and analyzed using a normal plot. In our opinion, the number of seeds sampled should be determined beforehand according to an a priori level of statistical uncertainty.

  9. The contribution of nitro- and methylnitronaphthalenes to the vapor-phase mutagenicity of ambient air samples

    NASA Astrophysics Data System (ADS)

    Gupta, Pamela; Harger, William P.; Arey, Janet

    1- and 2-Nitronaphthalene (NN) and the 14 methylnitronaphthalene (MNN) isomers were identified and quantified in ambient vapor-phase samples collected in Redlands, CA during moderate photochemical air pollution. The mutagenic activities of NN and MNN standards were determined using a microsuspension-preincubation modification of the Ames Salmonella bacterial reversion assay in strain TA98 without microsomal activation. The calculated contributions of the NNs and MNNs to the total vapor-phase ambient mutagenic activity were ˜ 18 and ˜ 32% for daytime and nighttime composite samples, respectively. Enhanced mutagenic activity in the nighttime sample was attributed to NN and MNN formation from nighttime N03 radical-initiated reactions of naphthalene and the methylnaphthalenes.

  10. Atmospheric trace gas measurements with a new clean air sampling system

    SciTech Connect

    Leifer, R.; Sommers, K.; Guggenheim, S.F.

    1981-10-01

    The development of a new clean air sampling system for the Department of Energy's WB-57F aircraft has allowed the analysis of CCl/sub 3/F (Fluorocarbon-11), CCl/sub 2/F/sub 2/ (Fluorocarbon-12), CHClF/sub 2/ (Fluorocarbon-22), C/sub 2/Cl/sub 3/F/sub 3/ (Fluorocarbon-113), CH/sub 4/, CO, CO/sub 2/, N/sub 2/O, CH/sub 3/Cl, CCl/sub 4/, CH/sub 3/CCl/sub 3/, OCS and SF/sub 6/ in tropospheric and stratospheric samples. Samples collected during the interception of the plume from the eruption of Mount St. Helens indicate that OCS was injected into the stratosphere during the eruption. A large CO/sub 2/ gradient was found at 19.2 km on this flight.

  11. Site characterization summary report for dry weather surface water sampling upper East Fork Poplar Creek characterization area Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    SciTech Connect

    1996-08-01

    This report describes activities associated with conducting dry weather surface water sampling of Upper East Fork Poplar Creek (UEFPC) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. This activity is a portion of the work to be performed at UEFPC Operable Unit (OU) 1 [now known as the UEFPC Characterization Area (CA)], as described in the RCRA Facility Investigation Plan for Group 4 at the Oak- Ridge Y-12 Plant, Oak Ridge, Tennessee and in the Response to Comments and Recommendations on RCRA Facility Investigation Plan for Group 4 at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee, Volume 1, Operable Unit 1. Because these documents contained sensitive information, they were labeled as unclassified controlled nuclear information and as such are not readily available for public review. To address this issue the U.S. Department of Energy (DOE) published an unclassified, nonsensitive version of the initial plan, text and appendixes, of this Resource Conservation and Recovery Act (RCRA) Facility Investigation (RFI) Plan in early 1994. These documents describe a program for collecting four rounds of wet weather and dry weather surface water samples and one round of sediment samples from UEFPC. They provide the strategy for the overall sample collection program including dry weather sampling, wet weather sampling, and sediment sampling. Figure 1.1 is a schematic flowchart of the overall sampling strategy and other associated activities. A Quality Assurance Project Plan (QAPJP) was prepared to specifically address four rounds of dry weather surface water sampling and one round of sediment sampling. For a variety of reasons, sediment sampling has not been conducted and has been deferred to the UEFPC CA Remedial Investigation (RI), as has wet weather sampling.

  12. Polybrominated diphenyl ethers and alternative flame retardants in air and precipitation samples from the northern Lake Victoria region, East Africa.

    PubMed

    Arinaitwe, Kenneth; Muir, Derek C G; Kiremire, Bernard T; Fellin, Phil; Li, Henrik; Teixeira, Camilla

    2014-01-01

    High volume air and precipitation samples were collected close to the shore of Lake Victoria at Entebbe, Uganda, between October 2008 and July 2010 inclusive. Polybrominated diphenyl ethers (PBDEs) and alternative flame retardants (AFRs) were analyzed by GC-MS. BDEs 47, 99, and 209 were the predominant PBDEs with mean concentrations (in air) of 9.84, 4.38, 8.27 pg m(-3) and mean fluxes in precipitation of 3.40, 6.23, and 7.82 ng m(-2) sample(-1), respectively. 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), and hexabromocyclododecane (HBCDD), anti- and syn-Dechlorane plus were detected at levels comparable with those of PBDEs. Both PBDEs and AFRs in air generally increased from 2008 to 2010. Elevated PBDE concentrations in air were associated with slow moving low altitude air masses from the region immediately adjacent to the lake, while low concentrations were mostly associated with fast moving westerly and southwesterly air masses. Analysis of the octa- and nona-BDE profiles suggested photolysis and pyrolytic debromination of BDE-209 in the air samples. The highly halogenated and most abundant PBDEs and AFRs in air also predominated in precipitation samples. This is the first study to report flame retardants in high volume air samples and precipitation in Equatorial Africa. PMID:24400732

  13. Evaluation of passive air sampler calibrations: Selection of sampling rates and implications for the measurement of persistent organic pollutants in air

    NASA Astrophysics Data System (ADS)

    Melymuk, Lisa; Robson, Matthew; Helm, Paul A.; Diamond, Miriam L.

    2011-04-01

    Polyurethane foam (PUF) passive air samplers (PAS) are a common and highly useful method of sampling persistent organic pollutants (POP) concentrations in air. PAS calibration is necessary to obtain reasonable and comparable semi-quantitative measures of air concentrations. Various methods are found in the literature concerning PAS calibration. 35 studies on PAS use and calibration are examined here, in conjunction with a study involving 10 PAS deployed concurrently in outdoor air with a low-volume air sampler in order to measure the sampling rates of PUF-PAS for polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), polycyclic musks (PCMs), and polycyclic aromatic hydrocarbons (PAHs). Based on this analysis it is recommended that (1) PAS should be assumed to represent bulk rather than gas-phase compound concentrations due to the sampling of particle-bound compounds, (2) calibration of PAS sampling rates is more accurately achieved using an active low-volume air sampler rather than depuration compounds since the former measures gas- and particle-phase compounds and does so continuously over the deployment period of the PAS, and (3) homolog-specific sampling rates based on KOA groupings be used in preference to compound/congener-specific or single sampling rates.

  14. Soyuz 23 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    James, John T.

    2011-01-01

    Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 23 because of concerns that new air pollutants had been present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The TOC began to decline in late October, 2010. The toxicological assessment of 6 m-GSCs from the ISS is shown in Table 1. The recoveries of 13C-acetone, fluorobenzene, and chlorobenzene from the GSCs averaged 73, 82, and 59%, respectively. We are working to understand the sub-optimal recovery of chlorobenzene.

  15. The Use of Compensated Aerological No-Lift Balloons to Determine Relatively Long-Term Dry-Air Parcel Trajectories.

    NASA Astrophysics Data System (ADS)

    Terliuc, Benjamin; Asculai, Ephraim; Doron, Eli

    1983-10-01

    A method to compensate the loss of buoyancy due to gas leakage from aerological no-lift balloons is presented. The method is implemented by means of a double vessel device that supplies a constant liquid outflow at constant temperature. It is shown that the average buoyancy loss rate dependence on temperature is almost perfectly matched by the outflow rate dependence on temperature when soya-bean oil is used. The device is simple, inexpensive and can be easily manufactured using standard laboratory equipment.A simple and safe method to carry no-lift systems to prefixed levels is also presented. It is based on a single 30 g pilot balloon provided with a gas leakage nozzle, inflated with H2 to a calibrated initial free-lift. The balloon is totally emptied at the required level, and remains suspended from the no-lift system.The whole system can be easily prepared under field conditions to be used in long travel-time studies of dry-air parcel trajectories in the atmosphere.An example of the use of the improved method over complex terrain is presented. A no-lift system provided with a 1680 MHz radiosonde transmitter, was tracked by two RD-65 radio-theodolites, to investigate the effects of the topographic structure of the Lake Kinneret (Sea of Galilee) area on the Mediterranean sea breeze summer regime. The system was tracked for at least one hour, following a trajectory with severe vertical variations. This increases our confidence in the ability to track much longer trajectories, if required.

  16. Effect of open air drying, LPG based drier and pretreatments on the quality of Indian gooseberry (aonla).

    PubMed

    Gudapaty, Pratibha; Indavarapu, Srinivas; Korwar, Girish R; Shankar, Arun Kumar; Adake, Ravi Kant V; Bandi, Venkateshwarlu; Kanchu, Srinivas Rao

    2010-10-01

    The aonla fruits (whole fruit, pricking, splits, segments) were subjected to pretreatments like blanching, osmotic dehydration with salt (2%) and sugar (40%) in different experiments before drying to obtain a product with better keeping quality. An LPG based drier (CRIDA drier) with capacity to dry 50 kg of fresh Indian gooseberry (aonla) was used. Nutritional quality and rehydration characteristics of CRIDA drier dried products were higher and free from contamination. Drying time was shortest for blanched and osmotically dehydrated segments dried in CRIDA drier and the product had better vitamin C retention, rehydration characteristics and sensory acceptability compared to sun or cabinet drier dried product. The additional expenditure spent on gas in CRIDA drier is compensated by reduced labour cost and higher price for the better quality product. Alternate energy sources like biogas and biomass can be used as fuel in the CRIDA drier. PMID:23572683

  17. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    SciTech Connect

    Barnett, J. Matthew; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-02-17

    Since the mid-1980s, Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as the correction factor for self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. This value accounts for activity that cannot be detected by direct counting of alpha and beta particles. Emissions can be degraded or blocked by filter fibers for particles buried in the filter material or by inactive dust particles collected with the radioactive particles. These filters are used for monitoring air emissions from PNNL stacks for radioactive particles. This paper describes an effort to re-evaluate self-absorption effects in particulate radioactive air sample filters (Versapor® 3000, 47 mm diameter) used at PNNL. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Filter ratios were calculated by dividing the initial counts by the post-digestion counts with the expectation that post-digestion counts would be higher because digestion would expose radioactivity embedded in the filter in addition to that on top of the filter. Contrary to expectations, the post digestion readings were almost always lower than initial readings and averaged approximately half the initial readings for both alpha and beta activity. Before and after digestion readings appeared to be related to each other, but with a low coefficient of determination (R^2) value. The ratios had a wide range of values indicating that this method did not provide sufficient precision to quantify self

  18. Method validation program for the long duration sampling of PCDDs/PCDFs in ambient air

    SciTech Connect

    Maisel, B.E.; Hunt, G.T.; Hoyt, M.P.; Rowe, N.; Scarfo, L.

    1994-12-31

    A method validation program was completed to assess the technical viability of extended, long duration sampling periods (15- and 30-day) for the collection of PCDDs/PCDFs in ambient air in lieu of the 48-hour sampling periods typically employed. This long duration approach, if successful, would provide measurements data more representative of average ambient PCDDs/PCDFs levels on an annual basis, and hence provide enhanced support of the 1.0 pg/m{sup 3} annual ambient standard for PCDDs/PCDFs (expressed at 1987 EPA toxic equivalents) required by Connecticut regulation. The method validation program utilized nine collocated PUF samplers which were operated for 15-day and 30-day periods during each of two seasonal monitoring campaigns (winter and summer). Samples were analyzed using high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) based on EPA Method 8290. Each PUF cartridge consisted of two foam halves; the top half PUF and filter were analyzed as a single sample separately from the bottom half PUF section. This approach provided an assessment of analyte breakthrough using the sampling system for large sample volumes of approximately 4,000 m{sup 3} and 8,000 m{sup 3} for the 15-day and respectively.

  19. Dried Saliva Spot (DSS) as a Convenient and Reliable Sampling for Bioanalysis: An Application for the Diagnosis of Diabetes Mellitus.

    PubMed

    Numako, Masahiro; Takayama, Takahiro; Noge, Ichiro; Kitagawa, Yutaka; Todoroki, Kenichiro; Mizuno, Hajime; Min, Jun Zhe; Toyo'oka, Toshimasa

    2016-01-01

    This paper proposes the dried saliva spot (DSS) as a convenient sampling technique for bioanalysis. The analytical method with the DSS was used for the determination of D,L-lactic acid (D,L-LA) and the D/L ratio of diabetic patients and prediabetic persons for the simple screening of the disease. The D,L-LA in the DSS was labeled with a chiral reagent (DMT-3(S)-Apy) for carboxylic acids and determined by UPLC-ESI-MS/MS. The limits of detection (signal-to-noise ratio (S/N) = 3) for the DSS analysis were on the amol level (∼30 amol). Because good stability, recovery, accuracy, and precision of the D,L-LA for the DSS method was also obtained from the proposed procedure, the DSS method was applied to the determination of the D- and L-isomers of LA of diabetic patients, and prediabetic and healthy persons. The D/L-LA ratio by the present DSS method and the HbA1c value in blood were well-correlated to the serious diabetic patients, whereas the relation in the prediabetic persons was not very good. The reason seems to be due to the rough saliva sampling, and not to the DSS method, because strict regulation was not requested for the prediabetic and healthy persons. In order to have a successful DSS analysis, the stability of the target molecule, the detection sensitivity to the target molecule, and the validated determination method are important. PMID:26629726

  20. Passive air sampling of organochlorine pesticides, polychlorinated biphenyls, and polybrominated diphenyl ethers across the tibetan plateau.

    PubMed

    Wang, Xiao-Ping; Gong, Ping; Yao, Tan-Dong; Jones, Kevin C

    2010-04-15

    So far there are limited data on persistent organic pollutants (POPs) in the atmosphere of the Tibetan Plateau. XAD 2-resin based passive air samplers were therefore deployed for 1 year (between July 2007-June 2008) at 16 locations across the Tibetan Plateau. Based on previously reported sampling rates (R) derived in the north and south America, and their correlations with atmospheric temperature and pressure, R values in the present study were in the range of 2.2-3.3 m(3) d(-1) (average = 2.7 +/- 0.3). Derived air concentrations (pg/m(3)) ranged as follows: DDTs, 5-75; HCHs, 0.1-36; alpha-endosulfan, 0.1-10; HCB, 2.8-80; sum of 15 PCBs, 1.8-8.2; and sum of 9 PBDEs, 0.1-8.3. The highest DDTs occurred at Qamdo, where the sampling site is near to farm land, indicating the spatial distribution of DDTs across the plateau may be influenced by scattered local usage of DDT. Higher levels of HCHs were observed at sites with high elevation (>4000 m) and close to the China-India border, indicating possible long-range atmospheric transport. The highest levels of HCB, PCBs, and PBDEs were found at a site impacted by forest fire during the sampling campaign. PMID:20235613

  1. Indoor air sampling and mutagenicity studies related to emissions from unvented coal combustion

    SciTech Connect

    Mumford, J.L.; Harris, D.B.; Williams, K.; Chuang, J.C.; Cooke, M.

    1986-07-01

    The purpose of the study is to develop sampling strategies and bioassay methods for indoor air in homes. The work reported here was conducted to prepare for a joint U.S.-China field study in Xuan Wei County, Yunnan Province, southern China, where the residents traditionally burn coal or wood for domestic cooking and heating without flue ventilation. These residents are exposed daily to high levels of combustion smoke and have unusually high lung cancer mortality rates, the women's rate the highest in China, and the men's rate among the highest. The paper reports the chemical and biological characterization of coal emissions from a simulated combustion laboratory.

  2. Leukotriene-B4 concentrations in exhaled breath condensate and lung function after thirty minutes of breathing technically dried compressed air.

    PubMed

    Neubauer, Birger; Struck, Niclas; Mutzbauer, Till S; Schotte, Ulrich; Langfeldt, Norbert; Tetzlaff, Kay

    2002-01-01

    In previous studies it had been shown that leukotriene-B4 [LTB4] concentrations in the exhaled breath mirror the inflammatory activity of the airways if the respiratory tract has been exposed to occupational hazards. In diving the respiratory tract is exposed to cold and dry air and the nasopharynx, as the site of breathing-gas warming and humidification, is bypassed. The aim of the present study was to obtain LTB4-concentrations in the exhaled breath and spirometric data of 17 healthy subjects before and after thirty minutes of technically dried air breathing at normobar ambient pressure. The exhaled breath was collected non-invasively, via a permanently cooled expiration tube. The condensate was measured by a standard enzyme immunoassay for LTB4. Lung function values (FVC, FEV1, MEF 25, MEF 50) were simultaneously obtained by spirometry. The measured pre- and post-exposure LTB4- concentrations as well as the lung function values were in the normal range. The present data gave no evidence for any inflammatory activity in the subjects' airways after thirty minutes breathing technically dried air. PMID:12608592

  3. Effect of Drying Methods on the Steroidal Alkaloid Content of Potato Peels, Shoots and Berries.

    PubMed

    Hossain, Mohammad B; Brunton, Nigel P; Rai, Dilip K

    2016-01-01

    The present study has found that dried potato samples yielded significantly higher levels of steroidal alkaloids such as α-solanine and α-chaconine than the corresponding fresh samples, as determined by the UPLC-MS/MS technique. Among the drying techniques used, air drying had the highest effect on steroidal alkaloid contents, followed by freeze drying and vacuum oven drying. There was no significant difference between the freeze dried and vacuum oven dried samples in their α-chaconine contents. However, freeze dried potato shoots and berries had significantly higher α-solanine contents (825 µg/g dry weight (DW) in shoots and 2453 µg/g DW in berries) than the vacuum oven dried ones (325 µg/g dry weight (DW) in shoots and 2080 µg/g DW in berries). The kinetics of steroidal alkaloid contents of potato shoots during air drying were monitored over a period of 21 days. Both α-solanine and α-chaconine content increased to their maximum values, 875 µg/g DW and 3385 µg/g DW, respectively, after 7 days of drying. The steroidal alkaloid contents of the shoots decreased significantly at day 9, and then remained unchanged until day 21. In line with the potato shoots, air dried potato tuber peels also had higher steroidal alkaloid content than the freeze dried and vacuum oven dried samples. However, a significant decrease of steroidal alkaloid content was observed in air dried potato berries, possibly due to degradation during slicing of the whole berries prior to air drying. Remarkable variation in steroidal alkaloid contents among different tissue types of potato plants was observed with the potato flowers having the highest content. PMID:27023503

  4. Contemporary-use pesticides in personal air samples during pregnancy and blood samples at delivery among urban minority mothers and newborns.

    PubMed Central

    Whyatt, Robin M; Barr, Dana B; Camann, David E; Kinney, Patrick L; Barr, John R; Andrews, Howard F; Hoepner, Lori A; Garfinkel, Robin; Hazi, Yair; Reyes, Andria; Ramirez, Judyth; Cosme, Yesenia; Perera, Frederica P

    2003-01-01

    We have measured 29 pesticides in plasma samples collected at birth between 1998 and 2001 from 230 mother and newborn pairs enrolled in the Columbia Center for Children's Environmental Health prospective cohort study. Our prior research has shown widespread pesticide use during pregnancy among this urban minority cohort from New York City. We also measured eight pesticides in 48-hr personal air samples collected from the mothers during pregnancy. The following seven pesticides were detected in 48-83% of plasma samples (range, 1-270 pg/g): the organophosphates chlorpyrifos and diazinon, the carbamates bendiocarb and 2-isopropoxyphenol (metabolite of propoxur), and the fungicides dicloran, phthalimide (metabolite of folpet and captan), and tetrahydrophthalimide (metabolite of captan and captafol). Maternal and cord plasma levels were similar and, except for phthalimide, were highly correlated (p < 0.001). Chlorpyrifos, diazinon, and propoxur were detected in 100% of personal air samples (range, 0.7-6,010 ng/m(3)). Diazinon and propoxur levels were significantly higher in the personal air of women reporting use of an exterminator, can sprays, and/or pest bombs during pregnancy compared with women reporting no pesticide use or use of lower toxicity methods only. A significant correlation was seen between personal air level of chlorpyrifos, diazinon, and propoxur and levels of these insecticides or their metabolites in plasma samples (maternal and/or cord, p < 0.05). The fungicide ortho-phenylphenol was also detected in 100% of air samples but was not measured in plasma. The remaining 22 pesticides were detected in 0-45% of air or plasma samples. Chlorpyrifos, diazinon, propoxur, and bendiocarb levels in air and/or plasma decreased significantly between 1998 and 2001. Findings indicate that pesticide exposures are frequent but decreasing and that the pesticides are readily transferred to the developing fetus during pregnancy. PMID:12727605

  5. Estimation of sampling error uncertainties in observed surface air temperature change in China

    NASA Astrophysics Data System (ADS)

    Hua, Wei; Shen, Samuel S. P.; Weithmann, Alexander; Wang, Huijun

    2016-06-01

    This study examines the sampling error uncertainties in the monthly surface air temperature (SAT) change in China over recent decades, focusing on the uncertainties of gridded data, national averages, and linear trends. Results indicate that large sampling error variances appear at the station-sparse area of northern and western China with the maximum value exceeding 2.0 K2 while small sampling error variances are found at the station-dense area of southern and eastern China with most grid values being less than 0.05 K2. In general, the negative temperature existed in each month prior to the 1980s, and a warming in temperature began thereafter, which accelerated in the early and mid-1990s. The increasing trend in the SAT series was observed for each month of the year with the largest temperature increase and highest uncertainty of 0.51 ± 0.29 K (10 year)-1 occurring in February and the weakest trend and smallest uncertainty of 0.13 ± 0.07 K (10 year)-1 in August. The sampling error uncertainties in the national average annual mean SAT series are not sufficiently large to alter the conclusion of the persistent warming in China. In addition, the sampling error uncertainties in the SAT series show a clear variation compared with other uncertainty estimation methods, which is a plausible reason for the inconsistent variations between our estimate and other studies during this period.

  6. Extreme 13C depletion of CCl2F2 in firn air samples from NEEM, Greenland

    NASA Astrophysics Data System (ADS)

    Zuiderweg, A.; Holzinger, R.; Martinerie, P.; Schneider, R.; Kaiser, J.; Witrant, E.; Etheridge, D.; Petrenko, V.; Blunier, T.; Röckmann, T.

    2013-01-01

    A series of 12 high volume air samples collected from the S2 firn core during the North Greenland Eemian Ice Drilling (NEEM) 2009 campaign have been measured for mixing ratio and stable carbon isotope composition of the chlorofluorocarbon CFC-12 (CCl2F2). While the mixing ratio measurements compare favorably to other firn air studies, the isotope results show extreme 13C depletion at the deepest measurable depth (65 m), to values lower than δ13C = -80‰ vs. VPDB (the international stable carbon isotope scale), compared to present day surface tropospheric measurements near -40‰. Firn air modeling was used to interpret these measurements. Reconstructed atmospheric time series indicate even larger depletions (to -120‰) near 1950 AD, with subsequent rapid enrichment of the atmospheric reservoir of the compound to the present day value. Mass-balance calculations show that this change is likely to have been caused by a large change in the isotopic composition of anthropogenic CFC-12 emissions, probably due to technological advances in the CFC production process over the last 80 yr, though direct evidence is lacking.

  7. Extreme 13C depletion of CCl2F2 in firn air samples from NEEM, Greenland

    NASA Astrophysics Data System (ADS)

    Zuiderweg, A.; Holzinger, R.; Martinerie, P.; Schneider, R.; Kaiser, J.; Witrant, E.; Etheridge, D.; Rubino, M.; Petrenko, V.; Blunier, T.; Röckmann, T.

    2012-07-01

    A series of 12 high volume air samples collected from the S2 firn core during the North Greenland Eemian Ice Drilling (NEEM) 2009 campaign have been measured for mixing ratio and stable carbon isotope composition of the chlorofluorocarbon CFC-12 (CCl2F2). While the mixing ratio measurements compare favorably to other firn air studies, the isotope results show extreme 13C depletion at the deepest measurable depth (65 m), to values lower than δ13C = -80‰ vs. VPDB (the international stable carbon isotope scale), compared to present day surface tropospheric measurements near -40‰. Firn air modeling was used to interpret these measurements. Reconstructed atmospheric time series indicate even larger depletions (to -120‰) near 1950 AD, with subsequent rapid enrichment of the atmospheric reservoir of the compound to the present day value. Mass-balance calculations show that this change must have been caused by a large change in the isotopic composition of anthropogenic CFC-12 emissions, probably due to technological changes in the CFC production process over the last 80 yr. Propagating the mass-balance calculations into the future demonstrates that as emissions decrease to zero, isotopic fractionation by the stratospheric sinks will lead to continued 13C enrichment in atmospheric CFC-12.

  8. Optimisation steps of an innovative air sampling method for semi volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Lazarov, Borislav; Swinnen, Rudi; Spruyt, Maarten; Goelen, Eddy; Stranger, Marianne; Desmet, Gilbert; Wauters, Eric

    2013-11-01

    This work describes optimisation steps of an innovative method for the measurement several groups of semi-volatile organic compounds (SVOCs) in air, collecting both gaseous and particulate air fractions. It is based on active air sampling on sorption tubes (consisting of polydimethylsiloxane (PDMS) and Tenax TA), followed by thermal desorption and gas chromatography mass spectrometry analysis (TD-GC-MS). The optimised method was validated in the laboratory for the measurement of selected target compounds from the following chemical classes: polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and phthalate esters (PEs). It was applied in different Belgian urban outdoor as well as indoor environments. The new method is characterised by limits of detection in the range of 0.003-0.3 ng m-3 for PAHs, 0.004-0.2 ng m-3 for PCBs, 0.113-0.201 ng m-3 for PBDEs and 0.002-0.2 ng m-3 for PEs, a linearity of 0.996 and a repeatability of less than 10% for all studied compounds.

  9. Three-dimensional DEM-CFD analysis of air-flow-induced detachment of API particles from carrier particles in dry powder inhalers.

    PubMed

    Yang, Jiecheng; Wu, Chuan-Yu; Adams, Michael

    2014-02-01

    Air flow and particle-particle/wall impacts are considered as two primary dispersion mechanisms for dry powder inhalers (DPIs). Hence, an understanding of these mechanisms is critical for the development of DPIs. In this study, a coupled DEM-CFD (discrete element method-computational fluid dynamics) is employed to investigate the influence of air flow on the dispersion performance of the carrier-based DPI formulations. A carrier-based agglomerate is initially formed and then dispersed in a uniformed air flow. It is found that air flow can drag API particles away from the carrier and those in the downstream air flow regions are prone to be dispersed. Furthermore, the influence of the air velocity and work of adhesion are also examined. It is shown that the dispersion number (i.e., the number of API particles detached from the carrier) increases with increasing air velocity, and decreases with increasing the work of adhesion, indicating that the DPI performance is controlled by the balance of the removal and adhesive forces. It is also shown that the cumulative Weibull distribution function can be used to describe the DPI performance, which is governed by the ratio of the fluid drag force to the pull-off force. PMID:26579364

  10. Three-dimensional DEM–CFD analysis of air-flow-induced detachment of API particles from carrier particles in dry powder inhalers

    PubMed Central

    Yang, Jiecheng; Wu, Chuan-Yu; Adams, Michael

    2014-01-01

    Air flow and particle–particle/wall impacts are considered as two primary dispersion mechanisms for dry powder inhalers (DPIs). Hence, an understanding of these mechanisms is critical for the development of DPIs. In this study, a coupled DEM–CFD (discrete element method–computational fluid dynamics) is employed to investigate the influence of air flow on the dispersion performance of the carrier-based DPI formulations. A carrier-based agglomerate is initially formed and then dispersed in a uniformed air flow. It is found that air flow can drag API particles away from the carrier and those in the downstream air flow regions are prone to be dispersed. Furthermore, the influence of the air velocity and work of adhesion are also examined. It is shown that the dispersion number (i.e., the number of API particles detached from the carrier) increases with increasing air velocity, and decreases with increasing the work of adhesion, indicating that the DPI performance is controlled by the balance of the removal and adhesive forces. It is also shown that the cumulative Weibull distribution function can be used to describe the DPI performance, which is governed by the ratio of the fluid drag force to the pull-off force. PMID:26579364

  11. Cast Stone Oxidation Front Evaluation: Preliminary Results For Samples Exposed To Moist Air

    SciTech Connect

    Langton, C. A.; Almond, P. M.

    2013-11-26

    The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO{sub 4}{sup -} in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O{sub 4}{sup -}, which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate (Cr(VI) was used as a non-radioactive surrogate for pertechnetate, Tc(VII), in Cast Stone samples prepared with 5 M Simulant. Cast Stone spiked with pertechnetate was also prepared and tested. Depth discrete subsamples spiked with Cr were cut from Cast Stone exposed to Savannah River Site (SRS) outdoor ambient temperature fluctuations and moist air. Depth discrete subsamples spiked with Tc-99 were cut from Cast Stone exposed to laboratory ambient temperature fluctuations and moist air. Similar conditions are expected to be encountered in the Cast Stone curing container. The leachability of Cr and Tc-99 and the reduction capacities, measured by the Angus-Glasser method, were determined for each subsample as a function of depth from the exposed surface. The results obtained to date were focused on continued method development and are preliminary and apply to the sample composition and curing / exposure conditions described in this report. The

  12. Venturi air-jet vacuum ejectors for high-volume atmospheric sampling on aircraft platforms

    NASA Technical Reports Server (NTRS)

    Hill, Gerald F.; Sachse, Glen W.; Young, Douglas C.; Wade, Larry O.; Burney, Lewis G.

    1992-01-01

    Documentation of the installation and use of venturi air-jet vacuum ejectors for high-volume atmospheric sampling on aircraft platforms is presented. Information on the types of venturis that are useful for meeting the pumping requirements of atmospheric-sampling experiments is also presented. A description of the configuration and installation of the venturi system vacuum line is included with details on the modifications that were made to adapt a venturi to the NASA Electra aircraft at GSFC, Wallops Flight Facility. Flight test results are given for several venturis with emphasis on applications to the Differential Absorption Carbon Monoxide Measurement (DACOM) system at LaRC. This is a source document for atmospheric scientists interested in using the venturi systems installed on the NASA Electra or adapting the technology to other aircraft.

  13. Ram-air sample collection device for a chemical warfare agent sensor

    DOEpatents

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  14. Optimal Media for Use in Air Sampling To Detect Cultivable Bacteria and Fungi in the Pharmacy

    PubMed Central

    Joseph, Riya Augustin; Le, Theresa V.; Trevino, Ernest A.; Schaeffer, M. Frances; Vance, Paula H.

    2013-01-01

    Current guidelines for air sampling for bacteria and fungi in compounding pharmacies require the use of a medium for each type of organism. U.S. Pharmacopeia (USP) chapter <797> (http://www.pbm.va.gov/linksotherresources/docs/USP797PharmaceuticalCompoundingSterileCompounding.pdf) calls for tryptic soy agar with polysorbate and lecithin (TSApl) for bacteria and malt extract agar (MEA) for fungi. In contrast, the Controlled Environment Testing Association (CETA), the professional organization for individuals who certify hoods and clean rooms, states in its 2012 certification application guide (http://www.cetainternational.org/reference/CAG-009v3.pdf?sid=1267) that a single-plate method is acceptable, implying that it is not always necessary to use an additional medium specifically for fungi. In this study, we reviewed 5.5 years of data from our laboratory to determine the utility of TSApl versus yeast malt extract agar (YMEA) for the isolation of fungi. Our findings, from 2,073 air samples obtained from compounding pharmacies, demonstrated that the YMEA yielded >2.5 times more fungal isolates than TSApl. PMID:23903551

  15. SO 2 sorption characteristics of air sampling filter media using a new laboratory test

    NASA Astrophysics Data System (ADS)

    Batterman, Stuart; Osak, Igor; Gelman, Charles

    A significant factor in the selection of filter media used for air sampling is the formation of artifacts due to the sorption of sulfur and nitrogen oxides on the filter. These artifacts can erroneously increase measured particulate concentrations. A technique is developed to measure the uptake of SO 2 and other gases and vapors on air sampling filter media. The static chamber technique features in-chamber measurements of SO 2 concentrations using FTIR spectrometry. The filter uptake, partition coefficient, and diffusion coefficient are estimated from the loss of gaseous SO 2 in the chamber. The technique provides rapid and precise results over a wide range of filter characteristics and avoids problems related to the extraction of target analytes from the filter. A total of 12 types of filters are evaluated, including glass fiber, Teflon-coated glass fiber, nylon, quartz fiber, Teflon, Supor, Nylasorb, and acrylic copolymer membranes. Results indicate that Teflon, quartz and acrylic copolymer filters have minimal sorption of SO 2 while quartz fiber, Supor and Nylasorb filters have high to moderate uptake of SO 2.

  16. Optimal media for use in air sampling to detect cultivable bacteria and fungi in the pharmacy.

    PubMed

    Weissfeld, Alice S; Joseph, Riya Augustin; Le, Theresa V; Trevino, Ernest A; Schaeffer, M Frances; Vance, Paula H

    2013-10-01

    Current guidelines for air sampling for bacteria and fungi in compounding pharmacies require the use of a medium for each type of organism. U.S. Pharmacopeia (USP) chapter <797> (http://www.pbm.va.gov/linksotherresources/docs/USP797PharmaceuticalCompoundingSterileCompounding.pdf) calls for tryptic soy agar with polysorbate and lecithin (TSApl) for bacteria and malt extract agar (MEA) for fungi. In contrast, the Controlled Environment Testing Association (CETA), the professional organization for individuals who certify hoods and clean rooms, states in its 2012 certification application guide (http://www.cetainternational.org/reference/CAG-009v3.pdf?sid=1267) that a single-plate method is acceptable, implying that it is not always necessary to use an additional medium specifically for fungi. In this study, we reviewed 5.5 years of data from our laboratory to determine the utility of TSApl versus yeast malt extract agar (YMEA) for the isolation of fungi. Our findings, from 2,073 air samples obtained from compounding pharmacies, demonstrated that the YMEA yielded >2.5 times more fungal isolates than TSApl. PMID:23903551

  17. Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air.

    PubMed

    Attari, Seyed Ghavameddin; Bahrami, Abdolrahman; Shahna, Farshid Ghorbani; Heidari, Mahmoud

    2014-01-01

    A green, environmental friendly and sensitive method for determination of volatile organohalogen compounds was described in this paper. The method is based on a homemade sol-gel single-walled carbon nanotube/silica composite coated solid-phase microextraction to develop for sampling and analysis of Carbon tetrachloride, Benzotrichloride, Chloromethyl methyl ether and Trichloroethylene in air. Application of this method was investigated under different laboratory conditions. Predetermined concentrations of each analytes were prepared in a home-made standard chamber and the influences of experimental parameters such as temperature, humidity, extraction time, storage time, desorption temperature, desorption time and the sorbent performance were investigated. Under optimal conditions, the use of single-walled carbon nanotube/silica composite fiber showed good performance, high sensitive and fast sampling of volatile organohalogen compounds from air. For linearity test the regression correlation coefficient was more than 98% for analyte of interest and linear dynamic range for the proposed fiber and the applied Gas Chromatography-Flame Ionization Detector technique was from 1 to 100 ngmL(-1). Method detection limits ranged between 0.09 to 0.2 ngmL(-1) and method quantification limits were between 0.25 and 0.7 ngmL(-1). Single-walled carbon nanotube/silica composite fiber was highly reproducible, relative standard deviations were between 4.3 to 11.7 percent. PMID:25279223

  18. Annual Report: 2011-2012 Storm Season Sampling, Non-Dry Dock Stormwater Monitoring for Puget Sound Naval Shipyard, Bremerton, WA

    SciTech Connect

    Brandenberger, Jill M.; Metallo, David; Rupert, Brian; Johnston, Robert K.; Gebhart, Christine

    2013-07-03

    Annual PSNS non-dry dock storm water monitoring results for 2011-2012 storm season. Included are a brief description of the sampling procedures, storm event information, laboratory methods and data collection, a results and discussion section, and the conclusions and recommendations.

  19. Ultrasonic extraction and field-portable anodic stripping voltammetry for the determination of lead in workplace air samples.

    PubMed

    Ashley, K; Mapp, K J; Millson, M

    1998-10-01

    An on-site, field-portable analytical method for the determination of lead in workplace air samples, based on the use of ultrasonic extraction and anodic stripping voltammetry (ASV), was evaluated. Workplace air samples were obtained using a standard method involving particulate collection onto mixed cellulose ester membrane filters. Samples were collected at work sites where airborne particulates were generated from the abrasive blasting of lead-containing paint on highway bridges. Ultrasonic extraction (UE) of air filter samples in diluted nitric acid, followed by portable ASV, was used for the determination of lead. Also, performance evaluation samples consisting of reference materials of known lead concentration were subjected to the UE-ASV procedure for lead determination. Confirmatory analyses of the air filters and performance evaluation samples subjected to the UE-ASV lead measurement method were conducted by hotplate digestion in concentrated nitric acid and 30% hydrogen peroxide, followed by inductively coupled plasma-atomic emission spectrometric (ICP-AES) determination of lead. Recoveries of lead from performance evaluation materials (when using the UE-ASV method) were found to be quantitative. The performance of the UE-ASV method for lead in air filters was found to be acceptable, as evaluated by comparison with results from hotplate strong acid digestion followed by ICP-AES analysis. Based on the results of this study, the ultrasonic extraction/portable ASV procedure demonstrates potential for the on-site determination of lead in personal breathing zone and area air samples. PMID:9794065

  20. ANASORB{reg_sign} 747 - A universal sorbent for air sampling?

    SciTech Connect

    Harper, M.

    1997-12-31

    A sorbent to be used for air sampling must meet certain performance criteria including sample background, capacity, stability, and recovery. Anasorb{sup R} 747 is a proprietary 20/40 mesh beaded active carbon prepared from raw materials with a very low ash content in a process which creates a regular pore structure. The background is very low for both inorganic and organic species, and the surface is more inert and less hydrophilic than coconut charcoal, while capacity is similar. The low catalytic activity of the surface means samples of many reactive compounds remain stable for longer periods. The sorbent is compatible with most solvent systems in use (e.g. carbon disulfide, methylene chloride, methanol, dimethyformamide). Anasorb 747 can be coated with chemicals for efficient adsorption of inorganic gases, which can be analyzed at very low levels because of low background interference. A large number of validated sampling methods use Anasorb 747, including methods from OSHA and NIOSH, corporate industrial hygiene laboratories, various branches of the EPA, and international agencies. These methods refer to around fifty different gases and vapors. Although this sorbent is not compatible with some compounds (e.g. low molecular weight aldehydes) it is quite close to being of universal application.