Science.gov

Sample records for air hepa filter

  1. HEPA air filter (image)

    MedlinePlus

    ... pet dander and other irritating allergens from the air. Along with other methods to reduce allergens, such ... controlling the amount of allergens circulating in the air. HEPA filters can be found in most air ...

  2. HEPA filter dissolution process

    DOEpatents

    Brewer, K.N.; Murphy, J.A.

    1994-02-22

    A process is described for dissolution of spent high efficiency particulate air (HEPA) filters and then combining the complexed filter solution with other radioactive wastes prior to calcining the mixed and blended waste feed. The process is an alternate to a prior method of acid leaching the spent filters which is an inefficient method of treating spent HEPA filters for disposal. 4 figures.

  3. Hepa filter dissolution process

    DOEpatents

    Brewer, Ken N.; Murphy, James A.

    1994-01-01

    A process for dissolution of spent high efficiency particulate air (HEPA) filters and then combining the complexed filter solution with other radioactive wastes prior to calcining the mixed and blended waste feed. The process is an alternate to a prior method of acid leaching the spent filters which is an inefficient method of treating spent HEPA filters for disposal.

  4. HEPA filter dissolution process

    SciTech Connect

    Brewer, K.N.; Murphy, J.A.

    1992-12-31

    This invention is comprised of a process for dissolution of spent high efficiency particulate air (HEPA) filters and then combining the complexed filter solution with other radioactive wastes prior to calcining the mixed and blended waste feed. The process is an alternate to a prior method of acid leaching the spent filters which is an inefficient method of treating spent HEPA filters for disposal.

  5. Viral Penetration of High Efficiency Particulate Air (HEPA) Filters (PREPRINT)

    DTIC Science & Technology

    2009-09-01

    threatened deployment of biological 34 agents to produce casualties or disease in man or animals and damage to plants or 35 material. It is...viral weapons is not clearly defined. From a weapons standpoint, it 88 would be advantageous to create smaller particles, because they would remain...studies that 107 used an animal model (Burmester 1972, Hopkins1971) to assay the protection provided 108 by HEPA filters. The turn of the 21st

  6. HEPA Filter Use at the Hanford Site

    SciTech Connect

    Kriskovich, J. R.

    2002-02-28

    High Efficiency Particulate Air (HEPA) filters are relied upon at the Hanford site to support several different activities. Each facility relies upon the filters to provide the same function; remove radioactive particulate from various air streams. However, HEPA filters are operated in differing environmental conditions from one facility to another and the constituents in the air streams also differ. In addition, some HEPA filters at the Hanford site have been in service for several years. As a result, an assessment was performed which evaluated the service life and conditions of the HEPA filters at the Hanford site.

  7. HEPA filter encapsulation

    DOEpatents

    Gates-Anderson, Dianne D.; Kidd, Scott D.; Bowers, John S.; Attebery, Ronald W.

    2003-01-01

    A low viscosity resin is delivered into a spent HEPA filter or other waste. The resin is introduced into the filter or other waste using a vacuum to assist in the mass transfer of the resin through the filter media or other waste.

  8. DOE HEPA filter test program

    SciTech Connect

    1998-05-01

    This standard establishes essential elements of a Department of Energy (DOE) program for testing HEPA filters to be installed in DOE nuclear facilities or used in DOE-contracted activities. A key element is the testing of HEPA filters for performance at a DOE Filter Test Facility (FTF) prior to installation. Other key elements are (1) providing for a DOE HEPA filter procurement program, and (2) verifying that HEPA filters to be installed in nuclear facilities appear on a Qualified Products List (QPL).

  9. Radioactive air emissions notice of construction HEPA filtered vacuum radioactive air emission units

    SciTech Connect

    JOHNSON, R.E.

    1999-09-01

    This notice of construction (NOC) requests a categorical approval for construction and operation of certain portable high-efficiency particulate air (HEPA) filtered vacuum radionuclide airborne emission units (HVUs). Approval of this NOC application is intended to allow operation of the HVUs without prior project-specific approval. This NOC does not request replacement or supersedence of any previous agreements/approvals by the Washington State Department of Health for the use of vacuums on the Hanford Site. These previous agreement/approvals include the approved NOCs for the use of EuroClean HEPA vacuums at the T Plant Complex (routine technical meeting 12/10/96) and the Kelly Decontamination System at the Plutonium-Uranium Extraction (PUREX) Plant (routine technical meeting 06/25/96). Also, this NOC does not replace or supersede the agreement reached regarding the use of HEPA hand-held/shop-vacuum cleaners for routine cleanup activities conducted by the Environmental Restoration Project. Routine cleanup activities are conducted during the surveillance and maintenance of inactive waste sites (Radioactive Area Remedial Action Project) and inactive facilities. HEPA hand-held/shop-vacuum cleaners are used to clean up spot surface contamination areas found during outdoor radiological field surveys, and to clean up localized radiologically contaminated material (e.g., dust, dirt, bird droppings, animal feces, liquids, insects, spider webs, etc.). This agreement, documented in the October 12, 1994 Routine Meeting Minutes, is based on routine cleanup consisting of spot cleanup of low-level contamination provided that, in each case, the source term potential would be below 0.1 millirem per year.

  10. Define and Quantify the Physics of Air Flow, Pressure Drop and Aerosol Collection in Nuclear Grade HEPA Filters

    SciTech Connect

    Moore, Murray E.

    2015-02-23

    Objective: Develop a set of peer-review and verified analytical methods to adjust HEPA filter performance to different flow rates, temperatures and altitudes. Experimental testing will measure HEPA filter flow rate, pressure drop and efficiency to verify the analytical approach. Nuclear facilities utilize HEPA (High Efficiency Particulate Air) filters to purify air flow for workspace ventilation. However, the ASME AG-1 technical standard (Code on Nuclear Air and Gas Treatment) does not adequately describe air flow measurement units for HEPA filter systems. Specifically, the AG-1 standard does not differentiate between volumetric air flow in ACFM (actual cubic feet per minute)compared to mass flow measured in SCFM (standard cubic feet per minute). More importantly, the AG-1 standard has an overall deficiency for using HEPA filter devices at different air flow rates, temperatures, and altitudes. Technical Approach: The collection efficiency and pressure drops of 18 different HEPA filters will be measured over a range of flow rates, temperatures and altitudes. The experimental results will be compared to analytical scoping calculations. Three manufacturers have allocated six HEPA filters each for this effort. The 18 filters will be tested at two different flow rates, two different temperatures and two different altitudes. The 36 total tests will be conducted at two different facilities: the ATI Test facilities (Baltimore MD) and the Los Alamos National Laboratory (Los Alamos NM). The Radiation Protection RP-SVS group at Los Alamos has an aerosol wind tunnel that was originally designed to evaluate small air samplers. In 2010, modifications were started to convert the wind tunnel for HEPA filter testing. (Extensive changes were necessary for the required aerosol generators, HEPA test fixtures, temperature control devices and measurement capabilities.) To this date, none of these modification activities have been funded through a specific DOE or NNSA program. This is

  11. In-place HEPA (high efficiency, particulate air) filter testing at Hanford: Operating experiences, calibrations, and lessons learned

    SciTech Connect

    Flores, D.S.; Decelis, D.G.

    1989-10-01

    High Efficiency, Particulate Air (HEPA) Filters provide a minimum of 99.97% removal efficiency for particles greater than or equal to .3 microns in diameter. Each HEPA filter installation at Hanford is, at specified intervals, functionally tested for leaks. The test procedure involves a dioctylphthalate (DOP) smoke generator and a calibrated airborne particle detector. The DOP generator produces smoke of a known quantitative particle size distribution upstream of the filter. The airborne particle detector is first placed upstream, and then downstream of the filter to determine percent penetration. The smoke generator is characterized using a calibrated laser spectrometer, and the particle detector is calibrated using a calibrated picoammeter. 2 refs., 4 figs.

  12. Ceramic HEPA Filter Program

    SciTech Connect

    Mitchell, M A; Bergman, W; Haslam, J; Brown, E P; Sawyer, S; Beaulieu, R; Althouse, P; Meike, A

    2012-04-30

    Potential benefits of ceramic filters in nuclear facilities: (1) Short term benefit for DOE, NRC, and industry - (a) CalPoly HTTU provides unique testing capability to answer questions for DOE - High temperature testing of materials, components, filter, (b) Several DNFSB correspondences and presentations by DNFSB members have highlighted the need for HEPA filter R and D - DNFSB Recommendation 2009-2 highlighted a nuclear facility response to an evaluation basis earthquake followed by a fire (aka shake-n-bake) and CalPoly has capability for a shake-n-bake test; (2) Intermediate term benefit for DOE and industry - (a) Filtration for specialty applications, e.g., explosive applications at Nevada, (b) Spin-off technologies applicable to other commercial industries; and (3) Long term benefit for DOE, NRC, and industry - (a) Across industry, strong desire for better performance filter, (b) Engineering solution to safety problem will improve facility safety and decrease dependence on associated support systems, (c) Large potential life-cycle cost savings, and (d) Facilitates development and deployment of LLNL process innovations to allow continuous ventilation system operation during a fire.

  13. Aging assessment of nuclear air-treatment system HEPA filters and adsorbers. Volume 1, Phase 1

    SciTech Connect

    Winegardner, W.K.

    1993-08-01

    A Phase I aging assessment of high-efficiency particulate air (HEPA) filters and activated carbon gas adsorption units (adsorbers) was performed by the Pacific Northwest Laboratory (PNL) as part of the US Nuclear Regulatory Commission`s (NRC) Nuclear Plant Aging Research (NPAR) Program. Information concerning design features; failure experience; aging mechanisms, effects, and stressors; and surveillance and monitoring methods for these key air-treatment system components was compiled. Over 1100 failures, or 12 percent of the filter installations, were reported as part of a Department of Energy (DOE) survey. Investigators from other national laboratories have suggested that aging effects could have contributed to over 80 percent of these failures. Tensile strength tests on aged filter media specimens indicated a decrease in strength. Filter aging mechanisms range from those associated with particle loading to reactions that alter properties of sealants and gaskets. Low radioiodine decontamination factors associated with the Three Mile Island (TMI) accident were attributed to the premature aging of the carbon in the adsorbers. Mechanisms that can lead to impaired adsorber performance include oxidation as well as the loss of potentially available active sites as a result of the adsorption of pollutants. Stressors include heat, moisture, radiation, and airborne particles and contaminants.

  14. Analysis of an MCU HEPA filter

    SciTech Connect

    Peters, T. B.; Fondeur, F. F.

    2017-01-01

    A series of direct analyses on three portions (inlet, center, and outlet) of the High Efficiency Particulate Air (HEPA) filter material from the Modular Caustic-Side Solvent Extraction Unit (MCU) have been performed; this includes x-ray methods such as X-Ray Diffraction (XRD), Contained Scanning Electron Microscopy (CSEM) and X-Ray Fluorescence (XRF), as well as Fourier Transform InfraRed spectroscopy (FTIR). Additionally, two leaching studies (one with water, one with dichloromethane) have been performed on three portions (inlet, center, and outlet) of the HEPA filter material, with the leachates being analyzed by Inductively-coupled plasma emission spectroscopy (ICPES), Semi-Volatile Organic Analysis (SVOA) and gammascan. From the results of the analyses, SRNL feels that cesium-depleted solvent is being introduced into the HEPA filter. The most likely avenue for this is mechanical aerosolization of solvent, where the aerosol is then carried along an airstream into the HEPA filter. Once introduced into the HEPA filter media, the solvent wicks throughout the material, and migrates towards the outlet end. Once on the outlet end, continual drying could cause particulate flakes to exit the filter and travel farther down the airstream path.

  15. Mold colonization during use of preservative-treated and untreated air filters, including HEPA filters from hospitals and commercial locations over an 8-year period (1996-2003).

    PubMed

    Price, Daniel L; Simmons, Robert B; Crow, Sidney A; Ahearn, Donald G

    2005-07-01

    High efficiency particulate arrestance (HEPA; 99.97% efficient at 0.3 microm) filters, filters with ASHRAE particulate arrestance rating of 90-95% at 1 mum (90-95% filters), and lower efficiency cellulosic-polyester filters from air conditioning systems in hospitals and commercial buildings were removed from the systems and examined microscopically for mold colonization. Cellulosic-type filters from systems with water entrainment problems typically were colonized, or became colonized upon incubation in moisture chambers. Species of Acremonium, Aspergillus, and Cladosporium were most common. With air filters of all types, treatment of filter media with an antimicrobial preservative tended to reduce or delay colonization. Mold colonization of HEPA and 90-95% filters was observed most often on the load surfaces, but two untreated HEPA filters were permeated with fungi, one with Aspergillus flavus, the other with Cladosporium sp. Air filters in heating, ventilating, and air conditioning (HVAC) systems, particularly those with chronic or periodic exposure to moisture, may serve as point sources for indoor molds.

  16. Extraction of semivolatile organic compounds from high-efficiency particulate air (HEPA) filters by supercritical carbon dioxide

    SciTech Connect

    Schilling, J.B.

    1997-09-01

    Supercritical fluid extraction (SFE) using unmodified carbon dioxide has been explored as an alternative method for the extraction of semivolatile organic compounds from high-efficiency particulate air (HEPA) filters. HEPA filters provide the final stage of containment on many exhaust systems in US Department of Energy (DOE) facilities by preventing the escape of chemical and radioactive materials entrained in the exhausted air. The efficiency of the filters is tested by the manufacturer and DOE using dioctylphthalate (DOP), a substance regulated by the US Environmental Protection Agency under the Resource Conservation and Recovery Act. Therefore, the filters must be analyzed for semivolatile organics before disposal. Ninety-eight acid, base, and neutral semivolatile organics were spiked onto blank HEPA material and extracted using SFE, Soxhlet, automated Soxhlet, and sonication techniques. The SFE conditions were optimized using a Dionex SFE-703 instrument. Average recoveries for the 98 semivolatile compounds are 82.7% for Soxhlet, 74.0% for sonication, 70.2% for SFE, and 62.9% for Soxtec. Supercritical fluid extraction reduces the extraction solvent volume to 10--15 mL, a factor of 20--30 less than Soxhlet and more than 5 times less than Soxtec and sonication. Extraction times of 30--45 min are used compared to 16--18 h for Soxhlet extraction.

  17. In-place HEPA filter penetration test

    SciTech Connect

    Bergman, W.; Wilson, K.; Elliott, J.

    1997-08-01

    We have demonstrated the feasibility of conducting penetration tests on high efficiency particulate air (HEPA) filters as installed in nuclear ventilation systems. The in-place penetration test, which is designed to yield equivalent penetration measurements as the standard DOP efficiency test, is based on measuring the aerosol penetration of the filter installation as a function of particle size using a portable laser particle counter. This in-place penetration test is compared to the current in-place leak test using light scattering photometers for single HEPA filter installations and for HEPA filter plenums using the shroud method. Test results show the in-place penetration test is more sensitive than the in-place leak test, has a similar operating procedure, but takes longer to conduct. Additional tests are required to confirm that the in-place penetration test yields identical results as the standard dioctyl phthalate (DOP) penetration test for HEPA filters with controlled leaks in the filter and gasket and duct by-pass leaks. Further development of the procedure is also required to reduce the test time before the in-place penetration test is practical. 14 refs., 14 figs., 3 tabs.

  18. Degradation of HEPA filters exposed to DMSO

    SciTech Connect

    Bergman, W.; Wilson, K.; Larsen, G.

    1995-02-01

    Dimethyl sulfoxide (DMSO) sprays are being used to remove the high explosive (HE) from nuclear weapons in the process of their dismantlement. A boxed 50 cmf HEPA filter with an integral prefilter was exposed to DMSO vapor and aerosols that were generated by a spray nozzle to simulate conditions expected in the HE dissolution operation. After 198 hours of operation, the pressure drop of the filter had increased form 1.15 inches to 2,85 inches, and the efficiency for 0.3 {mu}m dioctyl sebacate (DOS) aerosols decreased form 99.992% to 98.6%. Most of the DMSO aerosols had collected as a liquid pool inside the boxed HEPA. The liquid was blown out of the filter exit with 100 cmf air flow at the end of the test. Since the filter still met the minimum allowed efficiency of 99.97% after 166 hours of exposure, we recommend replacing the filter every 160 hours of operation or sooner if the pressure drop increases by 50%. Examination of the filter showed that visible cracks appeared at the joints of the wooden frame and a portion of the sealant had pulled away from the frame. Since all of the DMSO will be trapped in the first HEPA filter, the second HEPA filter should not suffer from DMSO degradation. Thus the combined efficiency for the first filter (98.6%) and the second filter (99.97%) is 99.99996% for 0.3 {mu}m particles. If the first filter is replaced prior to its degradation, each of the filters will have 99.97% efficiency, and the combined efficiency will be 99.999991%. The collection efficiency for DMSO/HE aerosols will be much higher because the particle size is much greater.

  19. Water washable stainless steel HEPA filter

    SciTech Connect

    Phillips, Terrance D.

    2001-01-01

    The invention is a high efficiency particulate (HEPA) filter apparatus and system, and method for assaying particulates. The HEPA filter provides for capture of 99.99% or greater of particulates from a gas stream, with collection of particulates on the surface of the filter media. The invention provides a filter system that can be cleaned and regenerated in situ.

  20. Specification for HEPA filters used by DOE contractors

    SciTech Connect

    1997-01-01

    This standard establishes specification and testing requirements for High Efficiency Particulate Air (HEPA) filters procured to provide personnel and environmental protection when installed in DOE nuclear facilities. The standard specifies minimum requirements to be included in contractor specifications.

  1. Microanalysis of indoor aerosols and the impact of a compact high-efficiency particulate air (HEPA) filter system.

    PubMed

    Abraham, M E

    1999-03-01

    Aerosol particles in municipal atmospheres are of increasing public health concern; however, since most of our time is spent indoors, indoor aerosols must be researched in counterpart. Compact High-Efficiency Particulate Air (HEPA) filter systems are commonly employed in residences to alleviate airborne dust concentrations. In this study, a detailed and original methodology was used to determine concentrations and types of submicrometer aerosols, as well as of large (> 4 microns) dust particles. Scanning electron microscopy was used to quantify and characterize ambient aerosols collected from filtered and non-filtered rooms. Particle concentrations were significantly lower in samples collected in the presence of the filter system (mean 23 to 8 coarse particles liter-1, 63% reduction; 13 to 3 inorganic submicron particles cm-3, 76% reduction; 85 to 33 total submicron particles cm-3, 62% reduction; all P < 0.05). This study provides a new methodology for analysis of indoor aerosols and new data on their physico-chemical characteristics. Since the filter systems are effective at reducing submicron aerosol concentrations, they may improve the health of individuals such as asthmatics, who experience health problems caused by anthropogenic fine particles.

  2. HEPA Filter Performance under Adverse Conditions

    SciTech Connect

    Parsons, Michael; Hogancamp, Kristina; Alderman, Steven; Waggoner, Charles

    2007-07-01

    This study involved challenging nuclear grade high-efficiency particulate air (HEPA) filters under a variety of conditions that can arise in Department of Energy (DOE) applications such as: low or high RH, controlled and uncontrolled challenge, and filters with physically damaged media or seals (i.e., leaks). Reported findings correlate filter function as measured by traditional differential pressure techniques in comparison with simultaneous instrumental determination of up and down stream PM concentrations. Additionally, emission rates and failure signatures will be discussed for filters that have either failed or exceeded their usable lifetime. Significant findings from this effort include the use of thermocouples up and down stream of the filter housing to detect the presence of moisture. Also demonstrated in the moisture challenge series of tests is the effect of repeated wetting of the filter. This produces a phenomenon referred to as transient failure before the tensile strength of the media weakens to the point of physical failure. An evaluation of the effect of particle size distribution of the challenge aerosol on loading capacity of filters is also included. Results for soot and two size distributions of KCl are reported. Loading capacities for filters ranged from approximately 70 g of soot to nearly 900 g for the larger particle size distribution of KCl. (authors)

  3. Effect of DOP heterodispersion on HEPA-filter-penetration measurements

    SciTech Connect

    Bergman, W.; Biermann, A.

    1984-08-09

    The accuracy of the standard US test method for certifying High-Efficiency Particulate Air (HEPA) filters has been in question since the finding by Hinds, et al. that the dioctyl phthalate (DOP) aerosol used in the test is not monodisperse as had been assumed and that particle-size analyzers, or owls, could not distinguish between different particle-size distributions with the same owl reading. We have studied theoretically and experimentally the filter efficiency for different DOP size distributions with the same owl reading. Our studies show that the effect of varying DOP size distributions on the measured HEPA-filter penetration depends on the light-scattering-photometer response and on the HEPA-filter penetration curve, both measured as a function of particle size. HEPA-filter penetration for a heterodisperse DOP aerosol may be increased, decreased, or remain the same when compared to the filter penetration for monodisperse aerosols. Using experimental HEPA-filter penetration and photometer response curves, we show that heterodisperse DOP aerosols (D/sub cmd/ 0.19 and sigma g = 1.4) yield 24% lower penetrations than that for monodisperse DOP aerosols (D/sub cmd/ = 0.3 and sigma g = 1.0). This surprisingly small effect of the DOP heterodispersion on HEPA-filter penetration is due to the response function of the owl that is similar to the response of the photometer. Changes in the particle-size distribution are therefore seen in a similar fashion by both the photometer and the owl. We also show that replacing the owl with modern particle-size spectrometers may lead to large errors in filter penetration because the particle-size spectrometers do not provide measurements that correspond to the photometer measurements. 15 references, 16 figures.

  4. Performance of HEPA filters under hot dynamic conditions

    SciTech Connect

    Frankum, D.P.; Costigan, G.

    1995-02-01

    Accidents in nuclear facilities involving fires may have implications upon the ventilation systems where high efficiency particulate air (HEPA) filters are used to minimise the airborne release of radioactive or toxic particles. The Filter Development Section at Harwell Laboratory has been investigating the effect of temperature on the performance of HEPA filters under hot dynamic conditions[{sub 1}] for a number of years. The test rig is capable of delivering air flows of 10001/s (at ambient conditions) at temperatures up to 500{degrees}C, where measurements of the penetration and pressure drop across the filter are obtained. This paper reports the experiments on different constructions of HEPA filters; rectangular and circular. The filters were tested at an air temperature of 200{degrees}C for up to 48 hours at the rated airflow to assess their performance. The penetration measurements for rectangular filters were observed to be below 0.021% after prolonged operation. In a number of cases, holes appeared along the pleat creases of circular filters although the penetration remained below 1%. The sealing gasket for these filters was noted to deform with temperature, permitting a leakage path. A prototype high strength circular filter was evaluated at temperatures of up to 400{degrees}C with a penetration less than 0.65%.

  5. Multi-Canister overpack internal HEPA filters

    SciTech Connect

    SMITH, K.E.

    1998-11-03

    The rationale for locating a filter assembly inside each Multi-Canister Overpack (MCO) rather than include the filter in the Cold Vacuum Drying (CVD) process piping system was to eliminate the potential for contamination to the operators, processing equipment, and the MCO. The internal HEPA filters provide essential protection to facility workers from alpha contamination, both external skin contamination and potential internal depositions. Filters installed in the CVD process piping cannot mitigate potential contamination when breaking the process piping connections. Experience with K-Basin material has shown that even an extremely small release can result in personnel contamination and costly schedule disruptions to perform equipment and facility decontamination. Incorporating the filter function internal to the MCO rather than external is consistent with ALARA requirements of 10 CFR 835. Based on the above, the SNF Project position is to retain the internal HEPA filters in the MCO design.

  6. Solutions for Dioctyl Phthalate (DOP) tested high efficiency particulate air (HEPA) filters destined for disposal at Hanford, Washington

    SciTech Connect

    Gablin, K.A.

    1992-11-01

    In January 1992, Argonne National Laboratory East, Environmental and Waste Management Program, learned that a chemical material used for testing of all HEPA filters at the primary source, Flanders Filter, Inc. in Washington, NC, was considered a hazardous chemical by Washington State Dangerous Waste Regulations. These regulations are under the jurisdiction of the Washington Administration Code, Chapter 173-303, and therefore directly under impact the Hanford Site Solid Waste Acceptance Criteria. Dioctyl Phthalate, DOP'' as it is referred to in chemical abbreviation form, is added in small test quantities at the factory, at three Department of Energy (DOE) operated HEPA filter test facilities, and in the installed duct work at various operating laboratories or production facilities. When small amounts of radioactivity are added to the filter media in operation, the result is a mixed waste. This definition would normally only develop in the state of Washington since their acceptance criteria is ten times more stringent then the US Environmental Protection Agencys' (US EPA). Methods of Processing will be discussed, which will include detoxification, physical separation, heat and vacuum separation, and compaction. The economic impact of a mixed waste definition in the State of Washington, and an Low Level Waste (LLW) definition in other locations, may lend this product to be a prime candidate for commercial disposal in the future, or a possible de-listing by the State of Washington.

  7. Solutions for Dioctyl Phthalate (DOP) tested high efficiency particulate air (HEPA) filters destined for disposal at Hanford, Washington

    SciTech Connect

    Gablin, K.A.

    1992-11-01

    In January 1992, Argonne National Laboratory East, Environmental and Waste Management Program, learned that a chemical material used for testing of all HEPA filters at the primary source, Flanders Filter, Inc. in Washington, NC, was considered a hazardous chemical by Washington State Dangerous Waste Regulations. These regulations are under the jurisdiction of the Washington Administration Code, Chapter 173-303, and therefore directly under impact the Hanford Site Solid Waste Acceptance Criteria. Dioctyl Phthalate, ``DOP`` as it is referred to in chemical abbreviation form, is added in small test quantities at the factory, at three Department of Energy (DOE) operated HEPA filter test facilities, and in the installed duct work at various operating laboratories or production facilities. When small amounts of radioactivity are added to the filter media in operation, the result is a mixed waste. This definition would normally only develop in the state of Washington since their acceptance criteria is ten times more stringent then the US Environmental Protection Agencys` (US EPA). Methods of Processing will be discussed, which will include detoxification, physical separation, heat and vacuum separation, and compaction. The economic impact of a mixed waste definition in the State of Washington, and an Low Level Waste (LLW) definition in other locations, may lend this product to be a prime candidate for commercial disposal in the future, or a possible de-listing by the State of Washington.

  8. Criteria for calculating the efficiency of HEPA filters during and after design basis accidents

    SciTech Connect

    Bergman, W.; First, M.W.; Anderson, W.L.; Gilbert, H.; Jacox, J.W.

    1994-12-01

    We have reviewed the literature on the performance of high efficiency particulate air (HEPA) filters under normal and abnormal conditions to establish criteria for calculating the efficiency of HEPA filters in a DOE nonreactor nuclear facility during and after a Design Basis Accident (DBA). The literature review included the performance of new filters and parameters that may cause deterioration in the filter performance such as filter age, radiation, corrosive chemicals, seismic and rough handling, high temperature, moisture, particle clogging, high air flow and pressure pulses. The deterioration of the filter efficiency depends on the exposure parameters; in severe exposure conditions the filter will be structurally damaged and have a residual efficiency of 0%. Despite the many studies on HEPA filter performance under adverse conditions, there are large gaps and limitations in the data that introduce significant error in the estimates of HEPA filter efficiencies under DBA conditions. Because of this limitation, conservative values of filter efficiency were chosen when there was insufficient data.

  9. Preliminary studies to determine the shelf life of HEPA filters

    SciTech Connect

    Gilbert, H.; Fretthold, J.K.; Rainer, F.

    1995-02-01

    We have completed a preliminary study using filter media tests and filter qualification tests to investigate the effect of shelf-life on HEPA filter performance. Our media studies showed that the tensile strength decreased with age, but the data were not sufficient to establish a shelf-life. Thermogravimetric analyses demonstrated that one manufacturer had media with low tensile strength due to insufficient binder. The filter qualification tests (heated air and overpressure) conducted on different aged filters showed that filter age is not the primary factor affecting filter performance; materials and the construction design have a greater effect. An unexpected finding of our study was that sub-standard HEPA filters have been installed in DOE facilities despite existing regulations and filter qualification tests. We found that the filter with low tensile strength failed the overpressure test. The same filter had passed the heated air test, but left the filter so structurally weak, it was prone to blow-out. We recommend that DOE initiate a filter qualification program to prevent this occurrence.

  10. A review of DOE HEPA filter component test activities

    SciTech Connect

    Slawski, J.W.; Bresson, J.F.; Scripsick, R.C.

    1997-08-01

    All HEPA filters purchased for installation in DOE nuclear facilities are required to be tested at a Filter Test Facility (FTF) prior to installation. The number of HEPA filters purchased by DOE has been reduced so much that the Hanford FTF was closed. From Fiscal Year (FY) 1992 to 1994, funding was not provided to the FTF Technical Support Group (TSG) at the Los Alamos National Laboratory. As a consequence, Round Robin Tests (RRTs), performed twice each year by the FTFs to assess constituency of test results among the FTFs, were not performed in FY 1992 and FY 1993. The Annual Reports of FTF test activities were not prepared for FY 1992 - 1995. Technical support provided to the FTFs was minimal. There is talk of closing a second FTF, and ongoing discussions as to whether DOE will continue to fund operation of the FTFs. In FY 1994, DOE Defense Programs commenced funding the TSG. RRT data for FY 1994 and 1995 have been entered into the database; the FY 1994 RRT report has been issued; and the FY 1995 RRT report is in progress. Data from semiannual reports have been retrieved and entered into the database. Standards related to HEPA filter test and procurement activities are now scheduled for issuance by FY 1996. Continuation of these activities depends on whether DOE will continue to support the HEPA filter test program. The history and activities of the FTFs and the TSG at Los Alamos have been reported at previous Air Cleaning Conferences. Data from the FY 1991 Annual Report of FTF activities was presented at the 1992 Air Cleaning Conference. Preparation of the Annual Reports was temporarily suspended in 1992. However, all of the FTF Semiannual report data have been retrieved and entered into the data base. This paper focuses primarily on the results of HEPA filter tests conducted by FTFs during FY 1992 - FY 1995, and the possible effects of the DOE program uncertainties on the quality of HEPA filters for installation at the DOE sites. 15 refs., 13 tabs.

  11. Potential for HEPA filter damage from water spray systems in filter plenums

    SciTech Connect

    Bergman, W.; Fretthold, J.K.; Slawski, J.W.

    1997-08-01

    The water spray systems in high efficiency particulate air (HEPA) filter plenums that are used in nearly all Department of Energy (DOE) facilities for protection against fire was designed under the assumption that the HEPA filters would not be damaged by the water sprays. The most likely scenario for filter damage involves filter plugging by the water spray, followed by the fan blowing out the filter medium. A number of controlled laboratory tests that were previously conducted in the late 1980s are reviewed in this paper to provide a technical basis for the potential HEPA filter damage by the water spray system in HEPA filter plenums. In addition to the laboratory tests, the scenario for BEPA filter damage during fires has also occurred in the field. A fire in a four-stage, BEPA filter plenum at Rocky Flats in 1980 caused the first three stages of BEPA filters to blow out of their housing and the fourth stage to severely bow. Details of this recently declassified fire are presented in this paper. Although these previous findings suggest serious potential problems exist with the current water spray system in filter plenums, additional studies are required to confirm unequivocally that DOE`s critical facilities are at risk. 22 refs., 15 figs.

  12. Emery 3004 as a challenge aerosol for HEPA filter testing

    SciTech Connect

    Barber, J.D.; Gilles, D.A.

    1994-02-01

    HEPA filters are used in nuclear facilities for contamination control and air treatment and are constructed to be 99.97% efficient in trapping particles of 0.3 microns or larger in size. Prior to installation at Hanford facilities HEPA filters are tested against the manufacturer`s efficiency specifications by the Hanford Environmental Health Foundation using an aerosol with a monodispersed particle size of 0.3 microns. The oil or material used for generating the aerosol, has historically been Dioctl Phthalate (DOP). But, in 1980 DOP was classified as a suspected carcinogen, and the search for substitute materials was under way. Corn oil produced good quantities of the correct sized particles but it tended to clog the generating equipment; Polyethylene Glycol 400 (PEG) and Dioctl Sebacate (DOS) were also tried but failed for various reasons. Emery 304 was tested and produced a good quantity of correctly sized aerosol and did not clog or damage the equipment in any way. Upon further testing, in September 1992, the DOE Richland Operations authorized the use of Emery 304 for in situ HEPA filter testing on the Hanford site.

  13. Safety evaluation for packaging (onsite) for the Pacific Northwest National Laboratory HEPA filter box

    SciTech Connect

    McCoy, J.C.

    1998-07-15

    This safety evaluation for packaging (SEP) evaluates and documents the safe onsite transport of eight high-efficiency particulate air (HEPA) filters in the Pacific Northwest National Laboratory HEPA Filter Box from the 300 Area of the Hanford Site to the Central Waste Complex and on to burial in the 200 West Area. Use of this SEP is authorized for 1 year from the date of release.

  14. Phase I characterization of the HEPA (High Efficiency Particulate Air) filter media used in the airborne activity confinement system at the Savannah River Site

    SciTech Connect

    Novick, V.J.; Higgins, P.J. )

    1989-01-01

    The purpose of this report was to characterize the HEPA filter media material. This work consisted of two major tasks. First, the pressure drop characteristics of the HEPA filter material were measured as a function of the aerosol mass loading. Particle size effects were studied by using three different particle size distributions to load the filter material. The second task was to determine the filtration efficiency spectrum for solid particles as a function of particle diameter. The filtration efficiency was measured at two different media velocities, one corresponding to the equivalent flow rate under normal operating conditions, the other corresponding to the minimum equivalent flow rate expected through the filter compartments. These tests were conducted at the Argonne National Laboratory between September 1988 and February 1989. 20 refs., 31 figs., 10 tabs.

  15. Effect of humidity and particle hygroscopicity on the mass loading capacity of high efficiency particulate air (HEPA) filters

    SciTech Connect

    Gupta, A.; Biswas, P. ); Monson, P.R. ); Novick, V.J. )

    1993-07-01

    The effect of humidity, particle hygroscopicity, and size on the mass loading capacity of glass fiber high efficiency particulate air filters was studied. Above the deliquescent point, the pressure drop across the filter increased nonlinearly with areal loading density (mass collected/filtration area) of a NaCl aerosol, thus significantly reducing the mass loading capacity of the filter compared to dry hygroscopic or nonhygroscopic particle mass loadings. The specific cake resistance K[sub 2] was computed for different test conditions and used as a measure of the mass loading capacity. K[sub 2] was found to decrease with increasing humidity for nonhygroscopic aluminum oxide particles and for hygroscopic NaCl particles (at humidities below the deliquescent point). It is postulated that an increase in humidity leads to the formation of a more open particulate cake which lowers the pressure drop for a given mass loading. A formula for predicting K[sub 2] for lognormally distributed aerosols (parameters obtained from impactor data) was derived. The resistance factor, R, calculated using this formula was compared to the theoretical R calculated using the Rudnick-Happel expression. For the nonhygroscopic aluminum oxide, the agreement was good but for the hygroscopic sodium chloride, due to large variation in the cake porosity estimates, the agreement was poor. 17 refs., 6 figs., 3 tabs.

  16. Feasibility study for an additional HEPA filter leaching system in NWCF

    SciTech Connect

    Willis, W.D.

    1992-11-01

    This report documents the feasibility of installing a second high-efficiency particulate air (HEPA) filter leaching system in the New Waste Calcining Facility at the Idaho Chemical Processing Plant (ICPP). A large spent filter backlog already exists at the ICPP, and it has been uncertain whether the existing HEPA filter leaching system will have a throughput rate sufficient to work off the existing backlog in a timely manner. Three areas within the New Waste Calcining Facility (NWCF) have been identified as possible locations for a second filter leaching system. This report examines the suitability of each location, identifies modifications that would be necessary-to install a filter leaching system at each location, examines the impact of modifying each location, and discusses recent efforts to estimate filter throughput using the existing filter leaching system. Based on all available information, installation of a second filter leaching system is not recommended at the present time.

  17. Development of a Pulp Process Treating Contaminated HEPA Filters (III)

    SciTech Connect

    Hu, J. S.; Ramer, J.; Argyle, M. D.; Demmer, R. L.

    2002-02-28

    The Pulp Process (PP) Treatment option was conceived as a replacement for the current Filter Leaching System (FLS). The FLS has operated at the Idaho Nuclear Technology and Engineering Center of the Idaho National Engineering and Environmental Laboratory since 1995 to treat radioactive, mixed waste HEPA filters. In recent years, the FLS has exhibited difficulty in removing mercury from the HEPA filters as the concentration of mercury in the spent HEPA filters has increased. The FLS leaches and washes the whole filter without any preparation or modification. The filter media and the trapped calcine particles are confined in a heavy filter housing that contributes to poor mixing zones around the edges of the filter, low media permeability, channeling of the liquid through cracks and tears in the filter media, and liquid retention between leach and rinse cycles. In the PP, the filter media and the trapped calcine particles are separated from the filter housing and treated as a pulp, taking advantage of improved contact with the leach solution that cannot be achieved when the media is still in the HEPA filter housing. In addition to removing the mercury more effectively, the PP generates less volume of liquid waste, requires a shorter leach cycle time, and possesses the versatility for treating filters of different sizes. A series of tests have been performed in the laboratory to demonstrate the advantages of the PP concept. These tests compare the PP with the FLS under controlled conditions that simulate the current operating parameters. A prior study using blended feed, a mixture of shredded clean HEPA filter media and non-radioactive calcine particles, indicated that the PP would significantly increases the calcine dissolution percentages. In this study, hazardous-metal contaminated HEPA filter media was studied. The results of side-by-side tests indicated that the PP increased the mercury removal percentage by 80% and might be a solution to the mercury removal

  18. ASME AG-1 Section FC Qualified HEPA Filters; a Particle Loading Comparison - 13435

    SciTech Connect

    Stillo, Andrew; Ricketts, Craig I.

    2013-07-01

    High Efficiency Particulate Air (HEPA) Filters used to protect personnel, the public and the environment from airborne radioactive materials are designed, manufactured and qualified in accordance with ASME AG-1 Code section FC (HEPA Filters) [1]. The qualification process requires that filters manufactured in accordance with this ASME AG-1 code section must meet several performance requirements. These requirements include performance specifications for resistance to airflow, aerosol penetration, resistance to rough handling, resistance to pressure (includes high humidity and water droplet exposure), resistance to heated air, spot flame resistance and a visual/dimensional inspection. None of these requirements evaluate the particle loading capacity of a HEPA filter design. Concerns, over the particle loading capacity, of the different designs included within the ASME AG-1 section FC code[1], have been voiced in the recent past. Additionally, the ability of a filter to maintain its integrity, if subjected to severe operating conditions such as elevated relative humidity, fog conditions or elevated temperature, after loading in use over long service intervals is also a major concern. Although currently qualified HEPA filter media are likely to have similar loading characteristics when evaluated independently, filter pleat geometry can have a significant impact on the in-situ particle loading capacity of filter packs. Aerosol particle characteristics, such as size and composition, may also have a significant impact on filter loading capacity. Test results comparing filter loading capacities for three different aerosol particles and three different filter pack configurations are reviewed. The information presented represents an empirical performance comparison among the filter designs tested. The results may serve as a basis for further discussion toward the possible development of a particle loading test to be included in the qualification requirements of ASME AG-1

  19. Method of treating contaminated HEPA filter media in pulp process

    DOEpatents

    Hu, Jian S.; Argyle, Mark D.; Demmer, Ricky L.; Mondok, Emilio P.

    2003-07-29

    A method for reducing contamination of HEPA filters with radioactive and/or hazardous materials is described. The method includes pre-processing of the filter for removing loose particles. Next, the filter medium is removed from the housing, and the housing is decontaminated. Finally, the filter medium is processed as pulp for removing contaminated particles by physical and/or chemical methods, including gravity, flotation, and dissolution of the particles. The decontaminated filter medium is then disposed of as non-RCRA waste; the particles are collected, stabilized, and disposed of according to well known methods of handling such materials; and the liquid medium in which the pulp was processed is recycled.

  20. Criteria for calculating the efficiency of deep-pleated HEPA filters with aluminum separators during and after design basis accidents

    SciTech Connect

    Bergman, W.; First, M.W.; Anderson, W.L.

    1995-02-01

    We have reviewed the literature on the performance of HEPA filters under normal and abnormal conditions to establish criteria for calculating the efficiency of HEPA filters in a DOE nonreactor nuclear facility during and after a Design Basis Accident (DBA). This study is only applicable to the standard deep-pleated HEPA filter with aluminum separators as specified in ASME N509[1]. Other HEPA filter designs such as the mini-pleat and separatorless filters are not included in this study. The literature review included the performance of new filters and parameters that may cause deterioration in the filter performance such as filter age, radiation, corrosive chemicals, seismic and rough handling, high temperature, moisture, particle clogging, high air flow and pressure pulses. The deterioration of the filter efficiency depends on the exposure parameters; in severe exposure conditions the filter will be damaged and have a residual efficiency of 0%. There are large gaps and limitations in the data that introduce significant error in the estimates of HEPA filter efficiencies under DBA conditions. Because of this limitation, conservative values of filter efficiency were chosen. The estimation of the efficiency of the HEPA filters under DBA conditions involves three steps: (1) The filter pressure drop and environmental parameters are determined during and after the DBA, (2) Comparing the filter pressure drop to a set of threshold values above which the filter is damaged. There is a different threshold value for each combination of environmental parameters, and (3) Determining the filter efficiency. If the filter pressure drop is greater than the threshold value, the filter is damaged and is assigned 0% efficiency. If the pressure drop is less, then the filter is not damaged and the efficiency is determined from literature values of the efficiency at the environmental conditions.

  1. Further development of the cleanable steel HEPA filter, cost/benefit analysis, and comparison with competing technologies

    SciTech Connect

    Bergman, W.; Lopez, R.; Wilson, K.

    1997-08-01

    We have made further progress in developing a cleanable steel fiber HEPA filter. We fabricated a pleated cylindrical cartridge using commercially available steel fiber media that is made with 1 {mu}m stainless steel fibers and sintered into a sheet form. Test results at the Department of Energy (DOE) Filter Test Station at Oak Ridge show the prototype filter cartridge has 99.99% efficiency for 0.3 {mu}m dioctyl phthalate (DOP) aerosols and a pressure drop of 1.5 inches. Filter loading and cleaning tests using AC Fine dust showed the filter could be repeatedly cleaned using reverse air pulses. Our analysis of commercially optimized filters suggest that cleanable steel HEPA filters need to be made from steel fibers less than 1{mu}m, and preferably 0.5 {mu}m, to meet the standard HEPA filter requirements in production units. We have demonstrated that 0.5 {mu}m steel fibers can be produced using the fiber bundling and drawing process. The 0.5 {mu}m steel fibers are then sintered into small filter samples and tested for efficiency and pressure drop. Test results on the sample showed a penetration of 0.0015 % at 0.3 {mu}m and a pressure drop of 1.15 inches at 6.9 ft/min (3.5 cm/s) velocity. Based on these results, steel fiber media can easily meet the requirements of 0.03 % penetration and 1.0 inch of pressure drop by using less fibers in the media. A cost analysis of the cleanable steel HEPA filter shows that, although the steel HEPA filter costs much more than the standard glass fiber HEPA filter, it has the potential to be very cost effective because of the high disposal costs of contaminated HEPA filters. We estimate that the steel HEPA filter will save an average of $16,000 over its 30 year life. The additional savings from the clean-up costs resulting from ruptured glass HEPA filters during accidents was not included but makes the steel HEPA filter even more cost effective. 33 refs., 28 figs., 1 tab.

  2. Comparison of MERV 16 and HEPA filters for cab filtration of underground mining equipment

    PubMed Central

    Cecala, A.B.; Organiscak, J.A.; Noll, J.D.; Zimmer, J.A.

    2016-01-01

    Significant strides have been made in optimizing the design of filtration and pressurization systems used on the enclosed cabs of mobile mining equipment to reduce respirable dust and provide the best air quality to the equipment operators. Considering all of the advances made in this area, one aspect that still needed to be evaluated was a comparison of the efficiencies of the different filters used in these systems. As high-efficiency particulate arrestance (HEPA) filters provide the highest filtering efficiency, the general assumption would be that they would also provide the greatest level of protection to workers. Researchers for the U.S. National Institute for Occupational Safety and Health (NIOSH) speculated, based upon a previous laboratory study, that filters with minimum efficiency reporting value, or MERV rating, of 16 may be a more appropriate choice than HEPA filters in most cases for the mining industry. A study was therefore performed comparing HEPA and MERV 16 filters on two kinds of underground limestone mining equipment, a roof bolter and a face drill, to evaluate this theory. Testing showed that, at the 95-percent confidence level, there was no statistical difference between the efficiencies of the two types of filters on the two kinds of mining equipment. As the MERV 16 filters were less restrictive, provided greater airflow and cab pressurization, cost less and required less-frequent replacement than the HEPA filters, the MERV 16 filters were concluded to be the optimal choice for both the roof bolter and the face drill in this comparative-analysis case study. Another key finding of this study is the substantial improvement in the effectiveness of filtration and pressurization systems when using a final filter design. PMID:27524838

  3. Further development of the cleanable steel HEPA filter, cost/benefit analysis, and comparison with competing technologies

    SciTech Connect

    Bergman, W.; Larsen, G.; Lopez, R.; Wilson, K.; Witherell, C.; McGregor, M.

    1997-01-01

    We have made further progress in developing a cleanable steel fiber HEPA filter. We fabricated a pleated cylindrical cartridge using commercially available steel fiber media that is made with 1 {mu}m stainless steel fibers and sintered into a sheet form. Test results at the Department of Energy (DOE) Filter Test Station at Oak Ridge show the prototype filter cartridge has 99.99% efficiency for 0.3 {mu}m dioctyl phthalate (DOP) aerosols and a pressure drop of 1.5 inches. Filter loading and cleaning tests using AC Fine dust showed the filter could be repeatedly cleaned using reverse air pulses. Our analysis of commercially optimized filters suggest that cleanable steel HEPA filters need to be made from steel fibers less than 1 {mu}m, and preferably 0.5 {mu}m, to meet the standard HEPA filter requirements in production units. We have demonstrated that 0.5 {mu}m steel fibers can be produced using the fiber bundling and drawing process. The 0.5 {mu}m steel fibers are then sintered into small filter samples and tested for efficiency and pressure drop. Test results on the sample showed a penetration of 0.0015% at 0.3 {mu}m and a pressure drop of 1.15 inches at 6.9 ft/min (3.5 cm/s) velocity. Based on these results, steel fiber media can easily meet the requirements of 0.03% penetration and 1.0 inch of pressure drop by using less fibers in the media. A cost analysis of the cleanable steel HEPA filter shows that, although the steel HEPA filter costs much more than the standard glass fiber HEPA filter, it has the potential to be very cost effective because of the high disposal costs of contaminated HEPA filters. We estimate that the steel HEPA filter will save an average of $16,000 over its 30 year life. The additional savings from the clean-up costs resulting from ruptured glass HEPA filters during accidents was not included but makes the steel HEPA filter even more cost effective. We also present the results of our evaluation of competing technologies with metallic and

  4. Performance Evaluation of Axial Flow AG-1 FC and Prototype FM (High Strength) HEPA Filters - 13123

    SciTech Connect

    Giffin, Paxton K.; Parsons, Michael S.; Wilson, John A.; Waggoner, Charles A.

    2013-07-01

    High efficiency particulate air (HEPA) filters are routinely used in DOE nuclear containment activities. The Nuclear Air Cleaning Handbook (NACH) stipulates that air cleaning devices and equipment used in DOE nuclear applications must meet the American Society of Mechanical Engineers (ASME) Code on Nuclear Air and Gas Treatment (AG-1) standard. This testing activity evaluates two different axial flow HEPA filters, those from AG-1 Sections FC and FM. Section FM is under development and has not yet been added to AG-1 due to a lack of qualification data available for these filters. Section FC filters are axial flow units that utilize a fibrous glass filtering medium. The section FM filters utilize a similar fibrous glass medium, but also have scrim backing. The scrim-backed filters have demonstrated the ability to endure pressure impulses capable of completely destroying FC filters. The testing activities presented herein will examine the total lifetime loading for both FC and FM filters under ambient conditions and at elevated conditions of temperature and relative humidity. Results will include loading curves, penetration curves, and testing condition parameters. These testing activities have been developed through collaborations with representatives from the National Nuclear Security Administration (NNSA), DOE Office of Environmental Management (DOE-EM), New Mexico State University, and Mississippi State University. (authors)

  5. HEPA Help

    ERIC Educational Resources Information Center

    Rathey, Allen

    2006-01-01

    Poor indoor air quality in school facilities can detract from the health and productivity of students, teachers and other employees. Asthma--often triggered or aggravated by dust--is the No. 1 cause of chronic absenteeism in schools. Using vacuum cleaners equipped with high-efficiency particulate air (HEPA) filters to clean education institutions…

  6. ALTERNATE HIGH EFFICIENCY PARTICULATE AIR (HEPA) FILTRATION SYSTEM

    SciTech Connect

    Bruce Bishop; Robert Goldsmith; Karsten Nielsen; Phillip Paquette

    2002-08-16

    In Phase IIA of this project, CeraMem has further developed and scaled up ceramic HEPA filters that are appropriate for use on filtration of vent gas from HLW tanks at DOE sites around the country. This work included procuring recrystallized SiC monoliths, developing membrane and cement materials, and defining a manufacturing process for the production of prototype full sizes HEPA filters. CeraMem has demonstrated that prototype full size filters can be manufactured by producing 9 full size filters that passed DOP aerosol testing at the Oak Ridge Filter Test Facility. One of these filters was supplied to the Savannah River Technical Center (SRTC) for process tests using simulated HLW tank waste. SRTC has reported that the filter was regenerable (with some increase in pressure drop) and that the filter retained its HEPA retention capability. CeraMem has also developed a Regenerable HEPA Filter System (RHFS) design and acceptance test plan that was reviewed by DOE personnel. The design and acceptance test plan form the basis of the system proposal for follow-on work in Phase IIB of this project.

  7. Testing cleanable/reuseable HEPA prefilters for mixed waste incinerator air pollution control systems

    SciTech Connect

    Burns, D.B.; Wong, A.; Walker, B.W.; Paul, J.D.

    1997-08-01

    The Consolidated Incineration Facility (CIF) at the US DOE Savannah River Site is undergoing preoperational testing. The CIF is designed to treat solid and liquid RCRA hazardous and mixed wastes from site operations and clean-up activities. The technologies selected for use in the air pollution control system (APCS) were based on reviews of existing incinerators, air pollution control experience, and recommendations from consultants. This approach resulted in a facility design using experience from other operating hazardous/radioactive incinerators. In order to study the CIF APCS prior to operation, a 1/10 scale pilot facility, the Offgas Components Test Facility (OCTF), was constructed and has been in operation since late 1994. Its mission is to demonstrate the design integrity of the CIF APCS and optimize equipment/instrument performance of the full scale production facility. Operation of the pilot facility has provided long-term performance data of integrated systems and critical facility components. This has reduced facility startup problems and helped ensure compliance with facility performance requirements. Technical support programs assist in assuring all stakeholders the CIF can properly treat combustible hazardous, mixed, and low-level radioactive wastes. High Efficiency Particulate Air (HEPA) filters are used to remove hazardous and radioactive particulates from the exhaust gas strewn before being released into the atmosphere. The HEPA filter change-out frequency has been a potential issue and was the first technical issue to be studied at the OCTF. Tests were conducted to evaluate the performance of HEPA filters under different operating conditions. These tests included evaluating the impact on HEPA life of scrubber operating parameters and the type of HEPA prefilter used. This pilot-scale testing demonstrated satisfactory HEPA filter life when using cleanable metal prefilters and high flows of steam and water in the offgas scrubber. 8 figs., 2 tabs.

  8. Health hazards associated with the use of di-(2-ethylhexyl) phthalate (commonly referred to as DOP) in HEPA filter test

    SciTech Connect

    1995-01-01

    Di-(2-ethylhexyl) phthalate (DEHP), commonly referred to as di-octyl phthalate, is an important production chemical in the US. In addition to its major use as an additive in plastics, DEHP is widely used to evaluate the effectiveness of high efficiency particulate air (HEPA) filters. Historically, DEHP was also used in quantitative fit testing for respirators. Evaluations of this compound a decade ago showed that it can induce hepatocellular carcinomas in laboratory animals. Although most Department of Energy (DOE) facilities have since discontinued using DEHP in respirator fit testing, DEHP continues to be used for evaluating HEPA filters. This report summarizes available information on the toxicity, mutagenicity, carcinogenicity, and other hazards and problems posed by DEHP, specifically with reference to HEPA filter testing. Information on work practice improvements as well as the availability and suitability of DEHP substitutes are also presented. This material should assist the DOE in the safe use of this material.

  9. HEPA Filter Disposal Write-Up 10/19/16

    SciTech Connect

    Loll, C.

    2016-10-20

    Process knowledge (PK) collection on HEPA filters is handled via the same process as other waste streams at LLNL. The Field technician or Characterization point of contact creates an information gathering document (IGD) in the IGD database, with input provided from the generator, and submits it for electronic approval. This document is essentially a waste generation profile, detailing the physical, chemical as well as radiological characteristics, and hazards, of a waste stream. It will typically contain a general, but sometimes detailed, description of the work processes which generated the waste. It will contain PK as well as radiological and industrial hygiene analytical swipe results, and any other analytical or other supporting knowledge related to characterization. The IGD goes through an electronic approval process to formalize the characterization and to ensure the waste has an appropriate disposal path. The waste generator is responsible for providing initial process knowledge information, and approves the IGD before it routed to chemical and radiological waste characterization professionals. This is the standard characterization process for LLNL-generated HEPA Filters.

  10. Method for HEPA filter leak scanning with differentiating aerosol detector

    SciTech Connect

    Kovach, B.J.; Banks, E.M.; Wikoff, W.O.

    1997-08-01

    While scanning HEPA filters for leaks with {open_quotes}Off the Shelf{close_quote} aerosol detection equipment, the operator`s scanning speed is limited by the time constant and threshold sensitivity of the detector. This is based on detection of the aerosol density, where the maximum signal is achieved when the scanning probe resides over the pinhole longer than several detector time-constants. Since the differential value of the changing signal can be determined by observing only the first small fraction of the rising signal, using a differentiating amplifier will speed up the locating process. The other advantage of differentiation is that slow signal drift or zero offset will not interfere with the process of locating the leak, since they are not detected. A scanning hand-probe attachable to any NUCON{reg_sign} Aerosol Detector displaying the combination of both aerosol density and differentiated signal was designed. 3 refs., 1 fig.

  11. Survey of HEPA filter applications and experience at Department of Energy sites

    SciTech Connect

    Carbaugh, E.H.

    1981-11-01

    Results indicated that approximately 58% of the filters surveyed were changed out in the 1977 to 1979 study period and some 18% of all filters were changed out more than once. Most changeouts (60%) were due to the existence of a high pressure drop across the filter, indicative of filter plugging. The next most recurrent reasons for changeout and their percentage changeouts were leak test failure (15%) and preventive maintenance service life limit (12%). An average filter service life was calculated to be 3.0 years with a 2.0-year standard deviation. The labor required for filter changeout was calculated as 1.5 manhours per filter changed. Filter failures occurred with approximately 12% of all installed filters. Most failures (60%) occurred for unknown reasons and handling or installation damage accounted for an additional 20% of all failures. Media ruptures, filter frame failures and seal failures occurred with approximately equal frequency at 5 to 6% each. Subjective responses to the questionnaire indicate problems are: need for improved acid and moisture resistant filters; filters more readily disposable as radioactive waste; improved personnel training in filter handling and installation; and need for pretreatment of air prior to HEPA filtration.

  12. Performance testing of HEPA filters: Progress towards a European standard procedure

    SciTech Connect

    Dyment, J.

    1997-08-01

    Proposals for a future European testing procedure for {open_quotes}High Efficiency Particulate Air Filters (HEPA and ULPA){close_quotes} are being developed by CEN (Comite Europeen de Normalisation). The new standard will be given the status of national standard in participating countries, conflicting national standards being withdrawn. The standard will comprise 5 parts covering the grouping and classification of HEPA and ULPA filters according to their efficiency, fundamental principles of testing, marking etc (in part 1). Part 2 will cover aerosol production, measurement principles, counting equipment and statistics. Parts 3-5 will cover testing flat sheet media, leak testing of filter elements and the efficiency testing of filter elements respectively. The efficiency test methods allow the use of either homogeneous monodisperse or polydisperse aerosols for the determination of particulate filtration efficiencies as a function of particle size. The particle size at which maximum penetration occurs is first determined in flat sheet media tests; tests on filter elements (constructed using the same filter medium) may be carried out using either a homogeneous monodisperse aerosol of the size at which maximum penetration occurs (MPPS) or a polydisperse aerosol whose median size is close to the MPPS. Tests with monodisperse aerosols may be conducted using condensation nucleus counting equipment; tests using polydisperse test aerosols require the use of optical sizing particle counters. When determining the efficiency of filter elements the downstream aerosol concentrations may be determined from air samples obtained using either an overall method (single point sampling after mixing) or a scan method. The scan method also allows {open_quotes}local{close_quotes} efficiency values to be determined. 1 ref., 1 fig., 1 tab.

  13. The case for improved HEPA-filter mechanical performance standards revisited

    SciTech Connect

    Ricketts, C.I.; Smith, P.R.

    1997-08-01

    Under benign operating conditions, High Efficiency Particulate Air (HEPA) filter units serve as reliable and relatively economical components in the air cleaning systems of nuclear facilities worldwide. Despite more than four decades of filter-unit evaluation and improvements, however, the material strength characteristics of the glass fiber filter medium continue to ultimately limit filter functional reliability. In worst-case scenarios involving fire suppression, loss-of-coolant accidents (LOCA`s), or exposure to shock waves or tornado induced flows, rupture of the filter medium of units meeting current qualification standards cannot be entirely ruled out. Even under so-called normal conditions of operation, instances of filter failure reported in the literature leave open questions of filter-unit reliability. Though developments of filter units with improved burst strengths have been pursued outside the United States, support for efforts in this country has been comparatively minimal. This despite user requests for filters with greater moisture resistance, for example. Or the fact that conventional filter designs result in not only the least robust component to be found in a nuclear air cleaning system, but also the one most sensitive to the adverse effects of conditions deviating from those of normal operation. Filter qualification-test specifications of current codes, standards, and regulatory guidelines in the United States are based primarily upon research performed in a 30-year period beginning in the 1950`s. They do not seem to reflect the benefits of the more significant developments and understanding of filter failure modes and mechanisms achieved since that time. One overseas design, based on such knowledge, has proven reliability under adverse operating conditions involving combined and serial challenges. Its widespread use, however, has faltered on a lack of consensus in upgrading filter performance standards. 34 refs., 2 figs., 3 tabs.

  14. A Survey of Mixed-Waste HEPA Filters in the DOE Complex

    SciTech Connect

    Felicione, F. S.; Barber, D. B.; Carney, K. P.

    2002-02-28

    A brief investigation was made to determine the quantities of spent, mixed-waste HEPA filters within the DOE Complex. The quantities of both the mixed-waste filters that are currently being generated, as well as the legacy mixed-waste filters being stored and awaiting disposition were evaluated. Seven DOE sites representing over 89% of the recent HEPA filter usage were identified. These sites were then contacted to determine the number of these filters that were likely destined to become mixed waste and to survey the legacy-filter quantities. Inquiries into the disposition plans for the filters were also made. It was determined that the seven sites surveyed possess approximately 500 m3 of legacy mixed-waste HEPA filters that will require processing, with an annual generation rate of approximately 25 m3. No attempt was made to extrapolate the results of this survey to the entire DOE Complex. These results were simply considered to be the lower bound of the totality of mixed-waste HEPA filters throughout the Complex. The quantities determined encourage the development of new treatment technologies for these filters, and provide initial data on which an appropriate capacity for a treatment process may be based.

  15. The development of a HEPA filter with improved dust holding characteristics

    SciTech Connect

    Dyment, J.; Hamblin, C.

    1995-02-01

    A limitation of the HEPA filters used in the extract of nuclear facilities is their relatively low capacity for captured dust. The costs associated with the disposal of a typical filter means that there are clear incentives to extend filter life. The work described in this report are the initial stages in the development of a filter which incorporates a medium which enhances its dust holding capacity. Experimental equipment was installed to enable the dust loading characteristics of candidate media to be compared with those of the glass fibre based papers currently used in filter construction. These tests involved challenging representative samples of the media with an air stream containing a controlled concentration of thermally generated sodium chloride particles. The dust loading characteristics of the media were then compared in terms of the rate of increasing in pressure differential. A number of {open_quotes}graded density{close_quotes} papers were subsequently identified which appeared to offer significant improvements in dust holding. In the second phase of the programme deep-pleat filters (1,700 M{sup 3}h{sup {minus}1}) incorporating graded density papers were manufactured and tested. Improvements of up to 50% were observed in their capacity for the sub-micron sodium chloride test dust. Smaller differences (15%) were measured when a coarser, carbon black, challenge was used. This is attributed to the differences in the particles sizes of the two dusts.

  16. Summary of meeting on disposal of LET&D HEPA filters

    SciTech Connect

    Not Available

    1991-11-21

    This report is a compilation of correspondence between Westinghouse Idaho Nuclear Company and the US EPA over a period of time from 1988 to 1992 (most from 1991-92) regarding waste management compliance with EPA regulations. Typical subjects include: compliance with satellite accumulation requirements; usage of ``Sure Shot`` containers in place of aerosol cans; notice of upcoming recyclable battery shipments; disposition of batteries; HEPA filter leach sampling and permit impacts; functional and operation requirements for the spent filter handling system; summary of meeting on disposal of LET and D HEPA filters; solvent substitution database report; and mercury vapor light analytical testing.

  17. In-place testing of tandem HEPA filter stages using fluorescent aerosols

    SciTech Connect

    Elder, J.C.; Kyle, T.G.; Tillery, M.I.; Ettinger, H.J.

    1980-01-01

    Fluorescent test aerosols were used in field testing of large multiple-stage HEPA filter systems. The technique excluded interference from non-fluorescent background particles known to leak into the plenum or ducting between the filters and the downstream sampling probe. This technique solved the problem of measuring extremely low concentrations of the test aerosol in the presence of background aerosol. The upstream fluorescent test aerosol was diluted with clean air and drawn into a single particle aerosol spectrometer capable of counting, sizing, and detecting fluorescence of each particle. The particle sizing function was performed on light scattered by the particle passing through the beam of a helium-cadmium laser. Concurrently the fluorescence excited by the laser illumination was detected at a longer wavelength. Since spectrometer response in the fluorescent mode was <2% of naturally occurring aerosols, background aerosols were insignificant as an interference to the downstream concentration measurement. Decontamination factors (DF) on the order of 10/sup 8/ were measured in the field studies on >9.4 m/sup 3//s (20,000 cfm) systems. Additional generator capacity and acceptably lower test aerosol to background aerosol concentraion ratios could be used to extend this capability to measure DF greater than 10/sup 8/. Dye-tagged DOP aerosols were generated either by gas-thermal or sonic nozzle generators. Experiments with the gas-thermal generator showed only 20% of fluorescence from the dye was degraded by the vaporization process. A single sonic nozzle was shown to aerosolize 0.7 to 1.0 L/h of dye-tagged DOP aerosol in the proper size range for HEPA filter testing. A multiple sonic nozzle generator is a practical consideration to provide greater capacity.

  18. Effects of filter housing and ductwork configuration on air flow uniformity inside air cleaning filter housings

    SciTech Connect

    Paul, J.D.

    1992-12-31

    Each new HEPA filter installation presents a different physical configuration based on the system requirements the available space and designer preference. Each different configuration can result in variations of air flow uniformity inside the filter housing across the filter banks. This paper will present the results of air flow uniformity testing for six different filter housing/ductwork configurations and discuss if any of the variations in air flow uniformity is attributable to the difference in the physical arrangements for the six cases.

  19. Effects of filter housing and ductwork configuration on air flow uniformity inside air cleaning filter housings

    SciTech Connect

    Paul, J.D.

    1992-01-01

    Each new HEPA filter installation presents a different physical configuration based on the system requirements the available space and designer preference. Each different configuration can result in variations of air flow uniformity inside the filter housing across the filter banks. This paper will present the results of air flow uniformity testing for six different filter housing/ductwork configurations and discuss if any of the variations in air flow uniformity is attributable to the difference in the physical arrangements for the six cases.

  20. HEPA filter leaching concept validation trials at the Idaho Chemical Processing Plant

    SciTech Connect

    Chakravartty, A.C.

    1995-04-01

    The enclosed report documents six New Waste Calcining Facility (NWCF) HEPA filter leaching trials conducted at the Idaho Chemical Processing Plant using a filter leaching system to validate the filter leaching treatment concept. The test results show that a modified filter leaching system will be able to successfully remove both hazardous and radiological constituents to RCRA disposal levels. Based on the success of the filter leach trials, the existing leaching system will be modified to provide a safe, simple, effective, and operationally flexible filter leaching system.

  1. Software Verification and Validation Test Report for the HEPA filter Differential Pressure Fan Interlock System

    SciTech Connect

    ERMI, A.M.

    2000-09-05

    The HEPA Filter Differential Pressure Fan Interlock System PLC ladder logic software was tested using a Software Verification and Validation (V&V) Test Plan as required by the ''Computer Software Quality Assurance Requirements''. The purpose of his document is to report on the results of the software qualification.

  2. Evaluation of the effect of media velocity on HEPA filter performance

    SciTech Connect

    Alderman, Steven; Parsons, Michael; Hogancamp, Kristina; Norton, O. Perry; Waggoner, Charles

    2007-07-01

    Section FC of the ASME AG-1 Code addresses glass fiber HEPA filters and restricts the media velocity to a maximum of 2.54 cm/s (5 ft/min). Advances in filter media technology allow glass fiber HEPA filters to function at significantly higher velocities and still achieve HEPA performance. However, diffusional capture of particles < 100 nm is reduced at higher media velocities due to shorter residence times within the media matrix. Therefore, it is unlikely that higher media velocities for HEPA filters will be allowed without data to demonstrate the effect of media velocity on removal of particles in the smaller size classes. In order to address this issue, static testing has been conducted to generate performance related data and a range of dynamic testing has provided data regarding filter lifetimes, loading characteristics, changes in filter efficiency and the most penetrating particle size over time. Testing was conducted using 31 cm x 31 cm x 29 cm deep pleat HEPA filters supplied from two manufacturers. Testing was conducted at media velocities ranging from 2.0-4.5 cm/s with a solid aerosol challenge composed of potassium chloride. Two set of media velocity data were obtained for each filter type. In one set of evaluations, the maximum aerosol challenge particle size was limited to 3 {mu}m, while particles above 3 {mu}m were not constrained in the second set. This provided for considerable variability in the challenge mass mean diameter and overall mass loading rate. Results of this testing will be provided to the ASME AG-1 FC Committee for consideration in future versions of the HEPA standard. In general, the initial filter efficiency decreased with increasing media velocity. However, initial filter efficiencies were generally good in all cases. Filter efficiency values averaged over the first ten minute of the loading cycle ranged from 99.970 to 99.996 %. Additionally, the most penetrating particle size was observed to decrease with increasing media velocity

  3. Test plan for N2 HEPA filters assembly shop stock used on PFP E4 exhaust system

    SciTech Connect

    DICK, J.D.

    1999-09-01

    At Plutonium Finishing Plant (PFP) and Plutonium Reclamation Facility (PRF) Self-contained HEPA filters, encased in wooden frames and boxes, are installed in the E4 Exhaust Ventilation System to provide confinement of radioactive releases to the environment and confinement of radioactive contamination within designated zones inside the facility. Recently during the routine testing in-leakage was discovered downstream of the Self-contained HEPA filters boxes. This Test Plan describes the approach to conduct investigation of the root causes for the in-leakage of HEPA filters.

  4. 340 vault K1 exhaust system HEPA filter evaluation

    SciTech Connect

    Arndt, T.E., Fluor Daniel Hanford

    1997-02-01

    A previous evaluation documented in report WHC-SD-GN-RPT-30005, Rev. 0, titled ``Evaluation on Self-Contained High Efficiency Particulate Filters,`` revealed that the SCHEPA filters do not have required documentation to be in compliance with the design, testing, and fabrication standards required in ASME N-509, ASME N-510, and MIL-F-51068. These standards are required by DOE Order 6430.IA. Without this documentation, filter adequacy cannot be verified. The existing SCHEPA filters can be removed and replaced with new filters and filter housing which meet current codes and standards.

  5. ANALYSIS OF VAPORS FROM METHYLENE CHLORIDE EXTRACTS OF NUCLEAR GRADE HEPA FILTER FIBERGLASS SAMPLES

    SciTech Connect

    FRYE JM; ANASTOS HL; GUTIERREZ FC

    2012-06-07

    While several organic compounds were detected in the vapor samples used in the reenactment of the preparation of mounts from the extracts of nuclear grade high-efficiency particulate air filter fiberglass samples, the most significant species present in the samples were methylene chloride, phenol, phenol-d6, and 2-fluorophenol. These species were all known to be present in the extracts, but were expected to have evaporated during the preparation of the mounts, as the mounts appeared to be dry before any vapor was collected. These species were present at the following percentages of their respective occupational exposure limits: methylene chloride, 2%; phenol, 0.4%; and phenol-d6, 0.6%. However, there is no established limit for 2-fluorophenol. Several other compounds were detected at low levels for which, as in the case of 2-fluorophenol, there are no established permissible exposure limits. These compounds include 2-chlorophenol; N-nitroso-1-propanamine; 2-fluoro-1,1{prime}-biphenyl; 1,2-dihydroacenaphthylene; 2,5-cyclohexadiene-1,4-dione,2,6-bis(1,1-dimethylethyl); trimethyl oxirane; n-propylpropanamine; 2-(Propylamino)ethanol; 4-methoxy-1-butene; 6-methyl-5-hepten-2-one; and 3,4-dimethylpyridine. Some of these were among those added as surrogates or spike standards as part ofthe Advanced Technologies and Laboratories International, Inc. preparation ofthe extract of the HEPA filter media and are indicated as such in the data tables in Section 2, Results; other compounds found were not previously known to be present. The main inorganic species detected (sulfate, sodium, and sulfur) are also consistent with species added in the preparation of the methylene chloride extract of the high-efficiency particulate air sample.

  6. Performance of HEPA filters at LLNL following the 1980 and 1989 earthquakes

    SciTech Connect

    Bergman, W.; Elliott, J.; Wilson, K.

    1994-11-01

    The Lawrence Livermore National laboratory has experienced two significant earthquakes for which data is available to assess the ability of HEPA filters to withstand seismic conditions. A 5.9 magnitude earthquake with an epicenter 10 miles from LLNL struck on January 24, 1980. Estimates of the peak ground accelerations ranged from 0.2 to 0.3 g. A 7.0 magnitude earthquake with an epicenter about 50 miles from LLNL struck on October 17, 1989. Measurements of the ground accelerations at LLNL averaged 0.1 g. The results from the in-place filter tests obtained after each of the earthquakes were compiled and studied to determine if the earthquakes had caused filter leakage. Our study showed that only the 1980 earthquake resulted in a small increase in the number of HEPA filters developing leaks. In the 12 months following the 1980 and 1989 earthquakes, the in-place filter tests showed 8.0% and 4.1% of all filters respectively developed leaks . The average percentage of filters developing leaks from 1980 to 1993 was 3.3% {plus_minus} 1.79%. The increase in the filter leaks is significant for the 1980 earthquake, but not for the 1989 earthquake. No contamination was detected following the earthquakes that would suggest transient releases from the filtration system.

  7. The effect of media area on the dust holding capacity of deep pleat HEPA filters

    SciTech Connect

    Dyment, J.; Loughborough, D.

    1997-08-01

    The high potential cost of storage, treatment and disposal of radioactive wastes places a premium on the longevity of installed HEPA filters in situations in radioactive processing facilities where dust capacity is a life determining factor. Previous work investigated the dust holding capacity v pressure drop characteristics of different designs of HEPA filter and also the effect of using graded density papers. This paper records an investigation of the effect of media area variation on the dust holding capacity of the {open_quotes}deep-pleat{close_quotes} design of HEPA filter. As in the previously reported work two test dusts (carbon black and sub micron sodium chloride) in the range (0.15 - 0.4{mu}m) were used. Media area adjustment was effected by varying the number of separators within the range 60 - 90. Results with the coarser dust allowed an optimum media area to be identified. Media areas greater or smaller than this optimum retained less dust than the optimum for the same terminal pressure drop. Conversely with the finer sodium chloride aerosol the dust holding capacity continued to increase up to the maximum area investigated. 7 refs., 4 figs.

  8. A Custom Robotic System for Inspecting HEPA Filters in the Payload Changeout Room at the NASA Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Spencer, James E., Jr.; Looney, Joe

    1994-01-01

    In this paper, the prime objective is to describe a custom 4-dof (degree-of-freedom) robotic arm capable of autonomously or telerobotically performing systematic HEPA filter inspection and certification in the Shuttle Launch Pad Payload Changeout Rooms (PCR's) on pads A and B at the Kennedy Space Center, Florida. This HEPA filter inspection robot (HFIR) has been designed to be easily deployable and is equipped with the necessary sensory devices, control hardware, software and man-machine interfaces needed to implement HEPA filter inspection reliably and efficiently without damaging the filters or colliding with existing PCR structures or filters. The main purpose of the HFIR is to implement an automated positioning system to move special inspection sensors in pre-defined or manual patterns for the purpose of verifying filter integrity and efficiency. This will ultimately relieve NASA Payload Operations from significant problems associated with time, cost and personnel safety, impacts realized during non-automated PCR HFIR filter certification.

  9. Fire tests to evaluate the potential fire threat and its effects on HEPA filter integrity in cell ventilation at the Oak Ridge National Laboratory, Building 7920

    SciTech Connect

    Hasegawa, H.K.; Staggs, K.J.; Doughty, S.M.

    1992-12-01

    As a result of a DOE (Tiger Team) Technical Safety Appraisal (November 1990) of the Radiochemical Engineering Development Center (REDC), ORNL Building 7920, a number of fire protection concerns were identified. The primary concern was the perceived loss of ventilation system containment due to the thermal destruction and/or breaching of the prefilters and/or high-efficiency particulate air filters (HEPA `s) and the resultant radioactive release to the external environment. The following report describes the results of an extensive fire test program performed by the Fire Research Discipline (FRD) of the Special Projects Division of Lawrence Livermore National Lab (LLNL) and funded by ORNL to address these concerns. Full scale mock-ups of a REDC hot cell tank pit, adjacent cubicle pit, and associated ventilation system were constructed at LLNL and 13 fire experiments were conducted to specifically answer the questions raised by the Tiger Team. Our primary test plan was to characterize the burning of a catastrophic solvent spill (kerosene) of 40 liters and its effect on the containment ventilation system prefilters and HEPA filters. In conjunction with ORNL and Lockwood Greene we developed a test matrix that assessed the fire performance of the prefilters and HEPA filters; evaluated the fire response of the fiber reinforced plastic (FRP) epoxy ventilation duct work; the response and effectiveness of the fire protection system, the effect of fire in a cubicle on the vessel off-gas (VOG) elbow, and other fire safety questions.

  10. Replacement of HEPA Filters at the LANL CMR Facility: Risks Reduced by Comprehensive Waste Characterization

    SciTech Connect

    Corpion, J.; Barr, A.; Martinez, P.; Bader, M.

    2002-02-28

    In March 2001, the Los Alamos National Laboratory (LANL) completed the replacement of 720 radioactively contaminated HEPA filters for $5.7M. This project was completed five months ahead of schedule and $6.0M under budget with no worker injuries or contaminations. Numerous health and safety, environmental, and waste disposal problems were overcome, including having to perform work in a radioactively contaminated work environment, that was also contaminated with perchlorates (potential explosive). High waste disposal costs were also an issue. A project risk analysis and government cost estimate determined that the cost of performing the work would be $11.8M. To reduce risk, a $1.2M comprehensive condition assessment was performed to determine the degree of toxic and radioactive contamination trapped on the HEPA filters; and to determine whether explosive concentrations of perchlorates were present. Workers from LANL and personnel from Waldheim International of Knoxville, TN collected hundreds of samples wearing personnel protective gear against radioactive, toxic, and explosive hazards. LANL also funded research at the New Mexico Institute of Mining and Technology to determine the explosivity of perchlorates. The data acquired from the condition assessment showed that toxic metals, toxic organic compounds, and explosive concentrations of perchlorates were absent. The data also showed that the extent of actinide metal contamination was less than expected, reducing the potential of transuranic waste generation by 50%. Consequently, $4.2M in cost savings and $1.8M in risk reduction were realized by increased worker productivity and waste segregation.

  11. Replacement of HEPA Filters at the LANL CMR Facility : risk reduced by comprehensive waste characterization

    SciTech Connect

    Corpion, J. C.

    2002-01-01

    In March 2001, the Los Alamos National Laboratory (LANL) completed the replacement of 720 radioactively contaminated HEPA filters for $5.7M. This project was completed five months ahead of schedule and $6.0M under budget with no worker injuries or contaminations. Numerous health and safety, environmental, and waste disposal problems were overcome, including having to perform work in a radioactively contaminated work environment, that was also contaminated with perchlorates (potential explosive). High waste disposal costs were also an issue. A project risk analysis and government cost estimate determined that the cost of performing the work would be $11.8M. To reduce risk, a $1.2M comprehensive condition assessment was performed to determine the degree of toxic and radioactive contamination trapped on the HEPA filters; and to determine whether explosive concentrations of perchlorates were present. Workers from LANL and personnel from Waldheim International of Knoxville, TN collected hundreds of samples wearing personnel protective gear against radioactive, toxic, and explosive hazards. LANL also funded research at the New Mexico Institute of Mining and Technology to determine the explosivity of perchlorates. The data acquired from the condition assessment showed that toxic metals, toxic organic compounds, and explosive concentrations of perchlorates were absent. The data also showed that the extent of actinide metal contamination was less than expected, reducing the potential of transuranic waste generation by 50%. Consequently, $4.2M in cost savings and $1.8M in risk reduction were realized by increased worker productivity and waste segregation.

  12. Development of the sampling and nuclide analysis methods for spent HEPA filter wastes

    SciTech Connect

    Young-Yong Ji; Dae Seok Hong; Il-Sik Kang; Bum-Kyoung Seo; Jong-Sik Shon

    2007-07-01

    Spent filter wastes of about 2,160 units have been stored in the waste storage facility of the Korea Atomic Energy Research Institute since its operation. These spent filters have generally consisted of a HEPA filter after its filtering of all the contaminants in the gas stream generated during the operation of the HANARO research reactor and the nuclear fuel cycle facilities. At the moment, to secure enough storage space, it is necessary to make a volume reduction of the stored radioactive wastes through a compression treatment or a regulatory clearance. There have been many studies on a treatment and a clearance of the low level radioactive wastes generated from nuclear facilities. These methods are used in view of a reduction of a management cost and disposal cost and the security of free space for a waste storage facility approaching saturation. In order to dispose of the spent filters, it is first necessary to conduct a radionuclide assessment of them. To do that, a sampling procedure should be prepared to obtain a representative sample from a spent filter. As for conducting a nuclide analysis for this representative sample, a corresponding spent filter can be determined as either a regulatory clearance waste or a radioactive waste. (authors)

  13. The high efficiency steel filters for nuclear air cleaning

    SciTech Connect

    Bergman, W.; Larsen, G.; Lopez, R.; Williams, K.; Violet, C.

    1990-08-01

    We have, in cooperation with industry, developed high-efficiency filters made from sintered stainless-steel fibers for use in several air-cleaning applications in the nuclear industry. These filters were developed to overcome the failure modes in present high-efficiency particulate air (HEPA) filters. HEPA filters are made from glass paper and glue, and they may fail when they get hot or wet and when they are overpressured. In developing our steel filters, we first evaluated the commercially available stainless-steel filter media made from sintered powder and sintered fiber. The sintered-fiber media performed much better than sintered-powder media, and the best media had the smallest fiber diameter. Using the best media, we then built prototype filters for venting compressed gases and evaluated them in our automated filter tester. 12 refs., 20 figs.

  14. A randomised controlled pilot study to compare filtration factor of a novel non-fit-tested high-efficiency particulate air (HEPA) filtering facemask with a fit-tested N95 mask.

    PubMed

    Au, S S W; Gomersall, C D; Leung, P; Li, P T Y

    2010-09-01

    Use of a fit-tested N95 or FFP2 mask is recommended to protect against transmission of airborne pathogens. This poses considerable logistic problems when preparing for, or dealing with, an epidemic. Some of these problems might be overcome by use of a compact reusable high-efficiency particulate air filtering mask that can be cut to size. We carried out a randomised controlled cross-over study to compare the efficacy of such a mask (Totobobo, Dream Lab One Pte Ltd, Singapore) with fit-tested N95 masks (1860 or 1860s or 1862; 3M, St Paul, MN, USA) in 22 healthy volunteers. The median (interquartile range) reduction in airborne particle counts was significantly higher [193-fold (145-200)] for N95 masks than for Totobobo masks [135-fold (83-184)] (P<0.05). There was no statistically significant difference between the proportion of subjects achieving a reduction of > or =100-fold between N95 (19/22) and Totobobo (16/22) masks. We conclude that use of the Totobobo mask without fit testing cannot be recommended, but its performance is sufficiently promising to warrant further investigation.

  15. Recirculating electric air filter

    DOEpatents

    Bergman, Werner

    1986-01-01

    An electric air filter cartridge has a cylindrical inner high voltage eleode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  16. Recirculating electric air filter

    DOEpatents

    Bergman, W.

    1985-01-09

    An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  17. Study of the effect of humidity, particle hygroscopicity and size on the mass loading capacity of HEPA filters

    SciTech Connect

    Gupta, A.

    1992-09-01

    The effect of humidity, particle hygroscopicity and size on the mass loading capacity of glass fiber HEPA filters has been studied. At humidifies above the deliquescent point, the pressure drop across the HEPA filter increased non-linearly with the areal loading density (mass collected/filtration area) of NaCl aerosol, thus significantly reducing the mass loading capacity of the filter compared to dry hygroscopic or non-hygroscopic particle mass loadings. The specific cake resistance, K{sub 2}, has been computed for different test conditions and used as a measure of the mass loading capacity. K. was found to decrease with increasing humidity for the non-hygroscopic aluminum oxide particles and the hygroscopic NaCl particles (at humidities below the deliquescent point). It is postulated that an increase in humidity leads to the formation of a more open particulate cake which lowers the pressure drop for a given mass loading. A formula for predicting K{sub 2} for lognormally distributed aerosols (parameters obtained from impactor data) is derived. The resistance factor, R, calculated using this formula was compared to the theoretical R calculated using the Rudnick-Happel expression. For the non-hygroscopic aluminum oxide the agreement was good but for the hygroscopic sodium chloride, due to large variation in the cake porosity estimates, the agreement was poor.

  18. Study of the effect of humidity, particle hygroscopicity and size on the mass loading capacity of HEPA filters

    SciTech Connect

    Gupta, A.

    1992-01-01

    The effect of humidity, particle hygroscopicity and size on the mass loading capacity of glass fiber HEPA filters has been studied. At humidifies above the deliquescent point, the pressure drop across the HEPA filter increased non-linearly with the areal loading density (mass collected/filtration area) of NaCl aerosol, thus significantly reducing the mass loading capacity of the filter compared to dry hygroscopic or non-hygroscopic particle mass loadings. The specific cake resistance, K{sub 2}, has been computed for different test conditions and used as a measure of the mass loading capacity. K. was found to decrease with increasing humidity for the non-hygroscopic aluminum oxide particles and the hygroscopic NaCl particles (at humidities below the deliquescent point). It is postulated that an increase in humidity leads to the formation of a more open particulate cake which lowers the pressure drop for a given mass loading. A formula for predicting K{sub 2} for lognormally distributed aerosols (parameters obtained from impactor data) is derived. The resistance factor, R, calculated using this formula was compared to the theoretical R calculated using the Rudnick-Happel expression. For the non-hygroscopic aluminum oxide the agreement was good but for the hygroscopic sodium chloride, due to large variation in the cake porosity estimates, the agreement was poor.

  19. Mold Occurring on the Air Cleaner High-Efficiency Particulate Air Filters Used in the Houses of Child Patients with Atopic Dermatitis

    PubMed Central

    Kim, Seong Hwan; Ahn, Geum Ran; Son, Seung Yeol; Bae, Gwi-Nam

    2014-01-01

    Fungi are the known sources of irritation associated with atopic diseases (e.g., asthma, allergic rhinoconjunctivitis, and atopic eczema). To quantitatively estimate their presence in the indoor environment of atopic dermatitis-inflicted child patient's houses (ADCPHs), the high-efficiency particulate air (HEPA) filters installed inside the air cleaners of three different ADCPHs were investigated for the presence of mold. The air cleaner HEPA filters obtained from the three different ADCPHs were coded as HEPA-A, -B, and -C, respectively, and tested for the presence of mold. The colony forming units (CFUs) corresponding to the HEPA-A, -B, and -C filters were estimated to be 6.51 × 102 ± 1.50 × 102 CFU/cm2, 8.72 × 102 ± 1.69 × 102 CFU/cm2, and 9.71 × 102 ± 1.35 × 102 CFU/cm2, respectively. Aspergillus, Penicillium, Alternaria, Cladosporium, Trichoderma, and other fungal groups were detected in the 2,494 isolates. The distribution of these fungal groups differed among the three filters. Cladosporium was the major fungal group in filters HEPA-A and -C, whereas Penicillium was the major fungal group in the filter HEPA-B. Nine fungal species, including some of the known allergenic species, were identified in these isolates. Cladosporium cladosporioides was the most common mold among all the three filters. This is the first report on the presence of fungi in the air cleaner HEPA filters from ADCPHs in Korea. PMID:25346608

  20. Mold occurring on the air cleaner high-efficiency particulate air filters used in the houses of child patients with atopic dermatitis.

    PubMed

    Kim, Seong Hwan; Ahn, Geum Ran; Son, Seung Yeol; Bae, Gwi-Nam; Yun, Yeo Hong

    2014-09-01

    Fungi are the known sources of irritation associated with atopic diseases (e.g., asthma, allergic rhinoconjunctivitis, and atopic eczema). To quantitatively estimate their presence in the indoor environment of atopic dermatitis-inflicted child patient's houses (ADCPHs), the high-efficiency particulate air (HEPA) filters installed inside the air cleaners of three different ADCPHs were investigated for the presence of mold. The air cleaner HEPA filters obtained from the three different ADCPHs were coded as HEPA-A, -B, and -C, respectively, and tested for the presence of mold. The colony forming units (CFUs) corresponding to the HEPA-A, -B, and -C filters were estimated to be 6.51 × 10(2) ± 1.50 × 10(2) CFU/cm(2), 8.72 × 10(2) ± 1.69 × 10(2) CFU/cm(2), and 9.71 × 10(2) ± 1.35 × 10(2) CFU/cm(2), respectively. Aspergillus, Penicillium, Alternaria, Cladosporium, Trichoderma, and other fungal groups were detected in the 2,494 isolates. The distribution of these fungal groups differed among the three filters. Cladosporium was the major fungal group in filters HEPA-A and -C, whereas Penicillium was the major fungal group in the filter HEPA-B. Nine fungal species, including some of the known allergenic species, were identified in these isolates. Cladosporium cladosporioides was the most common mold among all the three filters. This is the first report on the presence of fungi in the air cleaner HEPA filters from ADCPHs in Korea.

  1. Plutonium Finishing Plant (PFP) Waste Composition and High Efficiency Particulate Air Filter Loading

    SciTech Connect

    ZIMMERMAN, B.D.

    2000-12-11

    This analysis evaluates the effect of the Plutonium Finishing Plant (PFP) waste isotopic composition on Tank Farms Final Safety Analysis Report (FSAR) accidents involving high-efficiency particulate air (HEPA) filter failure in Double-Contained Receiver Tanks (DCRTs). The HEPA Filter Failure--Exposure to High Temperature or Pressure, and Steam Intrusion From Interfacing Systems accidents are considered. The analysis concludes that dose consequences based on the PFP waste isotopic composition are bounded by previous FSAR analyses. This supports USQD TF-00-0768.

  2. The Impacts of Traffic-Related and Woodsmoke Particulate Matter on Measures of Cardiovascular Health: A HEPA Filter Intervention Study

    PubMed Central

    Kajbafzadeh, Majid; Brauer, Michael; Karlen, Barbara; Carlsten, Chris; van Eeden, Stephan; Allen, Ryan W.

    2016-01-01

    Background Combustion-generated fine particulate matter (PM2.5) is associated with cardiovascular morbidity. Both traffic-related air pollution and residential wood combustion may be important, but few studies have compared their impacts. Objectives To assess and compare effects of traffic-related and woodsmoke PM2.5 on endothelial function and systemic inflammation (C-reactive protein, interleukin-6, and band cells) among healthy adults in Vancouver, British Columbia, Canada using high efficiency particulate air (HEPA) filtration to introduce indoor PM2.5 exposure gradients. Methods We recruited 83 healthy adults from 44 homes in traffic- or woodsmoke-impacted areas to participate in this randomized, single-blind crossover intervention study. PM2.5 concentrations were measured during two consecutive 7-day periods, one with filtration and the other with “placebo filtration”. Endothelial function and biomarkers of systematic inflammation were measured at the end of each 7-day period. Results HEPA filtration was associated with a 40% decrease in indoor PM2.5 concentrations. There was no relationship between PM2.5 exposure and endothelial function. There was evidence of an association between indoor PM2.5 and C-reactive protein among those in traffic-impacted locations [42.1% increase in C-reactive protein per interquartile range increase in indoor PM2.5, 95% CI, 1.2 to 99.5] but not among those in woodsmoke-impacted locations. There were no associations with interleukin-6 or band cells. Conclusions Evidence of an association between C-reactive protein and indoor PM2.5 among healthy adults in traffic-impacted areas is consistent with the hypothesis that traffic-related particles, even at relatively low concentrations, play an important role in the cardiovascular effects of the urban PM mixture. Trial registered at www.clinicaltrials.gov (NCT01570062) PMID:25896330

  3. Disinfecting Filters For Recirculated Air

    NASA Technical Reports Server (NTRS)

    Pilichi, Carmine A.

    1992-01-01

    Simple treatment disinfects air filters by killing bacteria, algae, fungi, mycobacteria, viruses, spores, and any other micro-organisms filters might harbor. Concept applied to reusable stainless-steel wire mesh filters and disposable air filters. Treatment used on filters in air-circulation systems in spacecraft, airplanes, other vehicles, and buildings to help prevent spread of colds, sore throats, and more-serious illnesses.

  4. Air Sampling Filter

    NASA Technical Reports Server (NTRS)

    1980-01-01

    General Metal Works' Accu-Vol is a high-volume air sampling system used by many government agencies to monitor air quality for pollution control purposes. Procedure prevents possible test-invalidating contamination from materials other than particulate pollutants, caused by manual handling or penetration of windblown matter during transit, a cassette was developed in which the filter is sealed within a metal frame and protected in transit by a snap-on aluminum cover, thus handled only under clean conditions in the laboratory.

  5. Summary of efficiency testing of standard and high-capacity high-efficiency particulate air filters subjected to simulated tornado depressurization and explosive shock waves

    SciTech Connect

    Smith, P.R.; Gregory, W.S.

    1985-04-01

    Pressure transients in nuclear facility air cleaning systems can originate from natural phenomena such as tornadoes or from accident-induced explosive blast waves. This study was concerned with the effective efficiency of high-efficiency particulate air (HEPA) filters during pressure surges resulting from simulated tornado and explosion transients. The primary objective of the study was to examine filter efficiencies at pressure levels below the point of structural failure. Both standard and high-capacity 0.61-m by 0.61-m HEPA filters were evaluated, as were several 0.2-m by 0.2-m HEPA filters. For a particular manufacturer, the material release when subjected to tornado transients is the same (per unit area) for both the 0.2-m by 0.2-m and the 0.61-m by 0.61-m filters. For tornado transients, the material release was on the order of micrograms per square meter. When subjecting clean HEPA filters to simulated tornado transients with aerosol entrained in the pressure pulse, all filters tested showed a degradation of filter efficiency. For explosive transients, the material release from preloaded high-capacity filters was as much as 340 g. When preloaded high-capacity filters were subjected to shock waves approximately 50% of the structural limit level, 1 to 2 mg of particulate was released.

  6. Highly Bactericidal Polyurethane Effective Against Both Normal and Drug-Resistant Bacteria: Potential Use as an Air Filter Coating.

    PubMed

    Taylor, Matthew; McCollister, Bruce; Park, Daewon

    2016-03-01

    The battle against the prevalence of hospital-acquired infections has underscored the importance of identifying and maintaining the cleanliness of possible infection transmission sources in the patient's environment. One of the most crucial lines of defense for mitigating the spread of pathogens in a healthcare facility is the removal of microorganisms from the environment by air filtration systems. After removing the pathogenic microorganisms, the filters used in these systems can serve as reservoirs for the pathogens and pose a risk for secondary infection. This threat, combined with the ever-growing prevalence of drug-resistant bacterial strains, substantiates the need for an effective bactericidal air filter. To this end, a broad-spectrum bactericidal polyurethane incorporating immobilized quaternary ammonium groups was developed for use as an air filter coating. In this study, the bactericidal activity of the polymer coating on high-efficiency particulate air (HEPA) filter samples was quantified against eight bacterial strains commonly responsible for nosocomial infection-including drug-resistant strains, and confirmed when applied as a filter coating in conditions mimicking those of its intended application. The coated HEPA filter samples exhibited high bactericidal activity against all eight strains, and the polyurethane was concluded to be an effective coating in rendering HEPA filters bactericidal.

  7. Air filtration in the free molecular flow regime: a review of high-efficiency particulate air filters based on carbon nanotubes.

    PubMed

    Li, Peng; Wang, Chunya; Zhang, Yingying; Wei, Fei

    2014-11-01

    Air filtration in the free molecular flow (FMF) regime is important and challenging because a higher filtration efficiency and lower pressure drop are obtained when the fiber diameter is smaller than the gas mean free path in the FMF regime. In previous studies, FMF conditions have been obtained by increasing the gas mean free path through reducing the pressure and increasing the temperature. In the case of carbon nanotubes (CNTs) with nanoscale diameters, it is possible to filtrate in the FMF regime under normal conditions. This paper reviews recent progress in theoretical and experimental studies of air filtration in the FMF regime. Typical structure models of high-efficiency particulate (HEPA) air filters based on CNTs are introduced. The pressure drop in air filters operated in the FMF regime is less than that predicted by the conventional air filtration theory. The thinnest HEPA filters fabricated from single-walled CNT films have an extremely low pressure drop. CNT air filters with a gradient nanostructure are shown to give a much better filtration performance in dynamic filtration. CNT air filters with a hierarchical structure and an agglomerated CNT fluidized bed air filter are also introduced. Finally, the challenges and opportunities for the application of CNTs in air filtration are discussed.

  8. High-efficiency particulate air filter test stand and aerosol generator for particle loading studies.

    PubMed

    Arunkumar, R; Hogancamp, Kristina U; Parsons, Michael S; Rogers, Donna M; Norton, Olin P; Nagel, Brian A; Alderman, Steven L; Waggoner, Charles A

    2007-08-01

    This manuscript describes the design, characterization, and operational range of a test stand and high-output aerosol generator developed to evaluate the performance of 30 x 30 x 29 cm(3) nuclear grade high-efficiency particulate air (HEPA) filters under variable, highly controlled conditions. The test stand system is operable at volumetric flow rates ranging from 1.5 to 12 standard m(3)/min. Relative humidity levels are controllable from 5%-90% and the temperature of the aerosol stream is variable from ambient to 150 degrees C. Test aerosols are produced through spray drying source material solutions that are introduced into a heated stainless steel evaporation chamber through an air-atomizing nozzle. Regulation of the particle size distribution of the aerosol challenge is achieved by varying source solution concentrations and through the use of a postgeneration cyclone. The aerosol generation system is unique in that it facilitates the testing of standard HEPA filters at and beyond rated media velocities by consistently providing, into a nominal flow of 7 standard m(3)/min, high mass concentrations (approximately 25 mg/m(3)) of dry aerosol streams having count mean diameters centered near the most penetrating particle size for HEPA filters (120-160 nm). Aerosol streams that have been generated and characterized include those derived from various concentrations of KCl, NaCl, and sucrose solutions. Additionally, a water insoluble aerosol stream in which the solid component is predominantly iron (III) has been produced. Multiple ports are available on the test stand for making simultaneous aerosol measurements upstream and downstream of the test filter. Types of filter performance related studies that can be performed using this test stand system include filter lifetime studies, filtering efficiency testing, media velocity testing, evaluations under high mass loading and high humidity conditions, and determination of the downstream particle size distributions.

  9. Particulate matter concentrations in residences: an intervention study evaluating stand-alone filters and air conditioners

    PubMed Central

    Batterman, S.; Du, L.; Mentz, G.; Mukherjee, B.; Parker, E.; Godwin, C.; Chin, J.-Y.; O'Toole, A.; Robins, T.; Rowe, Z.; Lewis, T.

    2014-01-01

    This study, a randomized controlled trial, evaluated the effectiveness of free-standing air filters and window air conditioners (ACs) in 126 low-income households of children with asthma. Households were randomized into a control group, a group receiving a free-standing HEPA filter placed in the child's sleeping area, and a group receiving the filter and a window-mounted AC. Indoor air quality (IAQ) was monitored for week-long periods over three to four seasons. High concentrations of particulate matter (PM) and carbon dioxide were frequently seen. When IAQ was monitored, filters reduced PM levels in the child's bedroom by an average of 50%. Filter use varied greatly among households and declined over time, for example, during weeks when pollutants were monitored, filter use was initially high, averaging 84 ± 27%, but dropped to 63 ± 33% in subsequent seasons. In months when households were not visited, use averaged only 34 ± 30%. Filter effectiveness did not vary in homes with central or room ACs. The study shows that measurements over multiple seasons are needed to characterize air quality and filter performance. The effectiveness of interventions using free-standing air filters depends on occupant behavior, and strategies to ensure filter use should be an integral part of interventions. PMID:22145709

  10. Study of loading/air back-pulse cleaning cycles on the performance of ceramic membrane filters

    SciTech Connect

    Waggoner, Charles; Alderman, Steven; Parsons, Michael; Hogoncamp, Kristina; Alderman, Steven

    2007-07-01

    Available in abstract form only. Full text of publication follows: The most commonly identified threats to conventional glass fiber HEPA filter performance are moisture and rapid blinding of filters by smoke. Regenerable filter media composed of ceramics or sintered metal can be utilized as pre-filters to protect the more vulnerable glass fiber HEPA filters in the event of upset conditions. Additionally, used in a pre-filtering application, the use of these regenerable filters can potentially extend the lifetime of conventional units. A series of tests have been conducted using CeraMem ceramic membrane filters in an effort to evaluate their performance after repeated loading and air back pulse cleaning. This was done in an effort to access filter performance after repeated loading/cleaning cycles. The filters were loaded using a solid potassium chloride aerosol challenge. The filters were evaluated for pressure drop and filtering efficiency changes from one cleaning cycle to the next. Additionally, the particle size distribution of the aerosol penetrating the filters was measured. (authors)

  11. Evaluation of the effect of media velocity on filter efficiency and most penetrating particle size of nuclear grade high-efficiency particulate air filters.

    PubMed

    Alderman, Steven L; Parsons, Michael S; Hogancamp, Kristina U; Waggoner, Charles A

    2008-11-01

    High-efficiency particulate air (HEPA) filters are widely used to control particulate matter emissions from processes that involve management or treatment of radioactive materials. Section FC of the American Society of Mechanical Engineers AG-1 Code on Nuclear Air and Gas Treatment currently restricts media velocity to a maximum of 2.5 cm/sec in any application where this standard is invoked. There is some desire to eliminate or increase this media velocity limit. A concern is that increasing media velocity will result in higher emissions of ultrafine particles; thus, it is unlikely that higher media velocities will be allowed without data to demonstrate the effect of media velocity on removal of ultrafine particles. In this study, the performance of nuclear grade HEPA filters, with respect to filter efficiency and most penetrating particle size, was evaluated as a function of media velocity. Deep-pleat nuclear grade HEPA filters (31 cm x 31 cm x 29 cm) were evaluated at media velocities ranging from 2.0 to 4.5 cm/sec using a potassium chloride aerosol challenge having a particle size distribution centered near the HEPA filter most penetrating particle size. Filters were challenged under two distinct mass loading rate regimes through the use of or exclusion of a 3 microm aerodynamic diameter cut point cyclone. Filter efficiency and most penetrating particle size measurements were made throughout the duration of filter testing. Filter efficiency measured at the onset of aerosol challenge was noted to decrease with increasing media velocity, with values ranging from 99.999 to 99.977%. The filter most penetrating particle size recorded at the onset of testing was noted to decrease slightly as media velocity was increased and was typically in the range of 110-130 nm. Although additional testing is needed, these findings indicate that filters operating at media velocities up to 4.5 cm/sec will meet or exceed current filter efficiency requirements. Additionally

  12. Test report for initial test of 6266 Building filter assemblies

    SciTech Connect

    Prather, M.C.

    1994-08-01

    This is the test report for the initial test of the Waste Sampling and Characterization Facility (WSCF) 6266 Building high efficiency particulate air (HEPA) filter assemblies. This supports the start-up of WSCF.

  13. Temperature Tunable Air-Gap Etalon Filter

    NASA Technical Reports Server (NTRS)

    Krainak, Michael A.; Stephen, Mark A.; Lunt, David L.

    1998-01-01

    We report on experimental measurements of a temperature tuned air-gap etalon filter. The filter exhibits temperature dependent wavelength tuning of 54 pm/C. It has a nominal center wavelength of 532 nm. The etalon filter has a 27 pm optical bandpass and 600 pm free spectral range (finesse approximately 22). The experimental results are in close agreement with etalon theory.

  14. Continuous air monitor filter changeout apparatus

    DOEpatents

    Rodgers, John C.

    2008-07-15

    An apparatus and corresponding method for automatically changing out a filter cartridge in a continuous air monitor. The apparatus includes: a first container sized to hold filter cartridge replacements; a second container sized to hold used filter cartridges; a transport insert connectively attached to the first and second containers; a shuttle block, sized to hold the filter cartridges that is located within the transport insert; a transport driver mechanism means used to supply a motive force to move the shuttle block within the transport insert; and, a control means for operating the transport driver mechanism.

  15. Extended-life nuclear air cleaning filters via dynamic exclusion prefilters

    SciTech Connect

    Wright, S.R.; Crouch, H.S.; Bond, J.H.

    1997-08-01

    The primary objective of this investigation was to ascertain if a dynamic, self-cleaning particulate exclusion precleaner, designed for relatively large dust removal (2 to 100+ {mu}m diameter particles) from helicopter turbine inlets, could be extended to submicron filtration. The improved device could be used as a prefilter for HEPA filtration systems, significantly increasing service life. In nuclear air cleaning, its use would reduce the amount of nuclear particulate matter that would otherwise be entrapped in the HEPA filter cartridge/panel, causing fouling and increased back pressure, as well as requiring subsequent disposal of the contaminated media at considerable expense. A unique (patent-pending) mechanical separation device has recently been developed to extract particulate matter from fluid process streams based on a proprietary concept called Boundary Layer Momentum Transfer (BLMT). The device creates multiple boundary layers that actively exclude particles from entering the perimeter of the device, while allowing air to traverse the boundaries relatively unimpeded. A modified two-dimensional (2-D) computerized flow simulation model was used to assist in the prototype design. Empirical results are presented from particle breakthrough and AP experiments obtained from a reduced-scale prototype filter. Particles larger than 0.23 {mu}m were actively excluded by the prototype, but at a higher pressure drop than anticipated. Experimental data collected indicates that the filter housing and the inlet flow configuration may contribute significantly to improvements in device particle separation capabilities. Furthermore, preliminary experiments have shown that other downstream pressure drop considerations (besides those just across the spinning filtration disks) must be included to accurately portray the AP across the device. Further detailed quantitative investigations on a larger scale (1,000 CFM) prototype are warranted. 3 refs., 5 figs., 2 tabs.

  16. Long duration tests of room air filters in cigarette smokers' homes.

    PubMed

    Batterman, Stuart; Godwin, Christopher; Jia, Chunrong

    2005-09-15

    Information regarding the long-term performance of stand-alone room airfilters is limited. In this study, laboratory and field tests were carried out to determine the effectiveness and performance of room filters that are easily deployed in essentially any type of house. Tests were conducted in houses containing strong PM sources, specifically cigarette smokers. Using commercially available four-speed HEPA filter units, we tested flow rate, pressure drop, and power consumption as a function of fan speed and filter loading. Filters were then deployed in four single-family homes over a 2 month period. Between 15 and 40 cigarettes were smoked daily by several smokers in each home. Occupants were instructed to continuously operate the unit at one of the higher speeds. Periodically, we monitored filter usage, fan speed, particulate matter (PM) mass concentrations, PM number concentrations, volatile organic compound (VOC) levels, and other parameters with the filter fan operating and with filters both installed and removed. The filters decreased PM concentrations by 30-70%, depending on size fraction and occupant activities, and significantly reduced the half-life of PM3-1.0. The half-life of 1-5 microm particles, CO2 concentrations, and VOC concentrations, including 2,5-dimethyl furan (a tracer for environmental tobacco smoke), did not change, indicating that occupancy and cigarette smoking intensity did not change overthe monitoring periods. Occupants generally kept the filters operating at a moderate speed. Filter air flow rates decreased 7-14% with extended operation, largely due to the loading of prefilters. Air exchange rates, deposition loss rates, and clean air delivery rates were estimated from the field data. Continuous operation at an intermediate fan speed would incur a total annualized cost of $236. While acceptance of the filters was very high, occupants might benefit from instructions and reminders to clean the prefilter and to keep the unit on. We

  17. Biological air filter for air-quality control

    NASA Astrophysics Data System (ADS)

    van Ras, Niels; Krooneman, Janneke; Ogink, Nico; Willers, Hans; D'Amico, Arnaldo; di Natale, Corrado; Godia, F.; Albiol, J.; Perez, J.; Martinez, N.; Dixon, Mike; Llewellyn, David; Eckhard, Fir; Zona, G.; Fachecci, L.; Kraakman, Bart; Demey, Dries; Michel, Noelle; Darlington, Alan

    2005-10-01

    Biological air filtration is a promising technique for air-quality control in closed environments in space and on Earth, and it offers several advantages over existing techniques. However, to apply it in these environments, specific criteria have to be met. A concept for biological air filtration in closed environments was developed and tested by an international team of specialists. Several model systems for closed environments in space and on Earth were used as a source of contaminated air. Conventional and new analytical techniques were used to determine odour composition and removal efficiency of the filter, including an "electronic nose". The results show that the developed biological air filter is suitable for treating contaminated air in closed environments. The developed electronic nose was shown to be a promising method for air-quality monitoring.

  18. Enhancing indoor air quality –The air filter advantage

    PubMed Central

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality. PMID:26628762

  19. Carbon fiber composite molecular sieve electrically regenerable air filter media

    DOEpatents

    Wilson, K.A.; Burchell, T.D.; Judkins, R.R.

    1998-10-27

    An electrically regenerable gas filter system includes a carbon fiber composite molecular sieve (CFCMS) filter medium. After a separate medium-efficiency pre-filter removes particulate from the supply air stream, the CFCMS filter sorbs gaseous air pollutants before the air is recirculated to the space. When saturated, the CFCMS media is regenerated utilizing a low-voltage current that is caused to pass through the filter medium. 3 figs.

  20. Nanofiber filter media for air filtration

    NASA Astrophysics Data System (ADS)

    Raghavan, Bharath Kumar

    Nanofibers have higher capture efficiencies in comparison to microfibers in the submicron particle size range of 100-500 nm because of small fiber diameter and increased surface area of the fibers. Pressure drop across the filter increases tremendously with decrease in fiber diameter in the continuum flow regime. Nanofibers with fiber diameter less than 300 nm are in the slip flow regime as a consequence of which steep increase in pressure drop is considerably reduced due to slip effect. The outlet or inlet gases have broad range of particle size distribution varying from few micrometers to nanometers. The economic benefits include capture of a wide range of particle sizes in the gas streams using compact filters composed of nanofibers and microfibers. Electrospinning technique was used to successfully fabricate polymeric and ceramic nanofibers. The nanofibers were long, continuous, and flexible with diameters in the range of 200--300 nm. Nanofibers were added to the filter medium either by mixing microfibers and nanofibers or by directly electrospinning nanofibers as thin layer on the surface of the microfiber filter medium. Experimental results showed that either by mixing Nylon 6 nanofibers with B glass fibers or by electrospinning Nylon 6 nanofibers as a thin layer on the surface of the microfiber medium in the surface area ratio of 1 which is 0.06 g of nanofibers for 2 g of microfibers performed better than microfiber filter media in air filtration tests. This improved performance is consistent with numerical modeling. The particle loading on a microfibrous filter were studied for air filtration tests. The experimental and modeling results showed that both pressure drop and capture efficiency increased with loading time. Nanofiber filter media has potential applications in many filtration applications and one of them being hot gas filtration. Ceramic nanofibers made of alumina and titania nanofibers can withstand in the range of 1000°C. Ceramic nanofibers

  1. Evaluation of HEPA vacuum cleaning and dry steam cleaning in reducing levels of polycyclic aromatic hydrocarbons and house dust mite allergens in carpets

    PubMed Central

    Yu, Chang Ho; Yiin, Lih-Ming; Fan, Zhi-Hua (Tina); Rhoads, George G.

    2014-01-01

    Dry steam cleaning, which has gained recent attention as an effective method to reduce house dust mite (HDM) allergen concentration and loading in carpets, was evaluated in this study for its efficacy in lowering levels of polycyclic aromatic hydrocarbons (PAHs) as well as HDM allergens. Fifty urban homes with wail-to-wall carpets, mostly low-income and with known lead contamination, were studied in 2003 and 2004. Two carpet-cleaning interventions were compared: Repeated HEPA (High Efficiency Particulate Air filtered) vacuuming alone and repeated HEPA vacuuming supplemented with dry steam cleaning. Vacuum samples were collected to measure carpet loading of dust and contaminants immediately before and after cleaning. Paired comparisons were conducted to evaluate the effectiveness of the cleaning protocols in reducing the levels of PAHs and HDM allergens in carpets. The results indicated that both cleaning methods substantially reduced the loading of PAHs and HDM allergens as well as dust in carpets (p < 0.0001). The reductions in loading of dust (64.4%), PAHs (69.1%), and HDM allergens (85.5%), by dry steam cleaning plus repetitive HEPA vacuuming were larger than the reductions by regular HEPA vacuuming alone: dust (55.5%), PAHs (58.6%), and HDM allergens (80.8%), although the difference was statistically significant only for dust and PAHs. We conclude that intensive HEPA vacuum cleaning substantially reduced the loading of PAHs and HDM allergens in carpets in these urban homes and that dry steam cleaning added modestly to cleaning effectiveness. PMID:19137159

  2. Pilot-scale tests of HEME and HEPA dissolution process

    SciTech Connect

    Qureshi, Z.H.; Strege, D.K.

    1994-06-01

    A series of pilot-scale demonstration tests for the dissolution of High Efficiency Mist Eliminators (HEME`s) and High Efficiency Particulate Airfilters (HEPA) were performed on a 1/5th linear scale. These fiberglass filters are to be used in the Defense Waste Processing Facility (DWPF) to decontaminate the effluents from the off-gases generated during the feed preparation process and vitrification. When removed, these filters will be dissolved in the Decontamination Waste Treatment Tank (DWTT) using 5 wt% NaOH solution. The contaminated fiberglass is converted to an aqueous stream which will be transferred to the waste tanks. The filter metal structure will be rinsed with process water before its disposal as low-level solid waste. The pilot-scale study reported here successfully demonstrated a simple one step process using 5 wt% NaOH solution. The proposed process requires the installation of a new water spray ring with 30 nozzles. In addition to the reduced waste generated, the total process time is reduced to 48 hours only (66% saving in time). The pilot-scale tests clearly demonstrated that the dissolution process of HEMEs has two stages - chemical digestion of the filter and mechanical erosion of the digested filter. The digestion is achieved by a boiling 5 wt% caustic solutions, whereas the mechanical break down of the digested filter is successfully achieved by spraying process water on the digested filter. An alternate method of breaking down the digested filter by increased air sparging of the solution was found to be marginally successful are best. The pilot-scale tests also demonstrated that the products of dissolution are easily pumpable by a centrifugal pump.

  3. Carbon fiber composite molecular sieve electrically regenerable air filter media

    DOEpatents

    Wilson, Kirk A.; Burchell, Timothy D.; Judkins, Roddie R.

    1998-01-01

    An electrically regenerable gas filter system includes a carbon fiber composite molecular sieve (CFCMS) filter medium. After a separate medium-efficiency pre-filter removes particulate from the supply airstream, the CFCMS filter sorbs gaseous air pollutants before the air is recirculated to the space. When saturated, the CFCMS media is regenerated utilizing a low-voltage current that is caused to pass through the filter medium.

  4. Viability of bacteria in unused air filter media

    NASA Astrophysics Data System (ADS)

    Maus, R.; Goppelsröder, A.; Umhauer, H.

    Different experimental techniques were applied to determine the effects of different air filter media on the viability of bacteria. Rinse suspensions of unused filter media were employed in standard inhibition tests to determine the effects of filter ingredients on bacterial growth under ideal nutritional conditions. Furthermore, a new test procedure was proposed and validated to determine the survival of viable microorganisms in fibrous air filters as a function of different parameters. Samples of filter media were challenged with microbial aerosols in an experimental set-up designed for measuring the collection efficiencies of fibrous filters. The loaded filter samples were then challenged with clean air under controlled conditions for a definite time span and numbers of viable microorganisms in the filter media were determined as colony forming units. The filter samples were retrieved from unused filter media usually employed in common air conditioning and ventilation systems. Under ideal nutritional and moisture conditions, growth of investigated microorganisms in nutrient broth and on nutrient agar was not inhibited by the inclusion of filter samples or rinse solutions of different filters in the growth medium with one exception. M. luteus and E. coli collected in air filter media and exposed to low air humidity (RH = 30-60%) showed a decline in their viability as a function of time (within 1 h). The decline rate was dependent on the type of bacteria employed and also the filter material itself.

  5. Evaluation of filters for removal of bacteriophages from air.

    PubMed

    Washam, C J; Black, C H; Sandine, W E; Elliker, P R

    1966-07-01

    Glass wool, nonabsorbent cotton, fiberglass filter medium, and a commercial absolute filter were tested for effectiveness in removing aerosolized bacterial viruses under low flow rate (1 ft(3)/min) and high flow rate (10 to 25 ft(3)/min) air-flow conditions. Special equipment was designed for measurement of filter efficiencies under the two air-flow conditions. Under low air-flow rate test conditions, glass wool was only 98.543 to 99.83% efficient, whereas cotton (five layers), fiberglass medium (three layers), and the commercial absolute filter were at least 99.900, 99.999, and 99.999 efficient, respectively. Glass wool and cotton were not used under higher air-flow conditions because they were difficult to assemble in leak-tight filters. The commercial absolute filter and fiberglass medium (three layers) were at least 99.990 and 99.999% efficient, respectively, under the higher air flow conditions. A stainless-steel filter of simple design and fitted with three layers of fiberglass medium was found to be greater than 99.999% efficient in removing high concentrations (20,000 to 70,000 plaque-forming units per cubic foot) of aerosolized bacteriophages from air moving at a low flow rate (1 ft(3)/min). Use of this filter on pressure-vacuum tanks in the fermentation industry is suggested. Several other uses of such a filter are proposed.

  6. Evaluation of Filters for Removal of Bacteriophages from Air1

    PubMed Central

    Washam, C. J.; Black, C. H.; Sandine, W. E.; Elliker, P. R.

    1966-01-01

    Glass wool, nonabsorbent cotton, fiberglass filter medium, and a commercial absolute filter were tested for effectiveness in removing aerosolized bacterial viruses under low flow rate (1 ft3/min) and high flow rate (10 to 25 ft3/min) air-flow conditions. Special equipment was designed for measurement of filter efficiencies under the two air-flow conditions. Under low air-flow rate test conditions, glass wool was only 98.543 to 99.83% efficient, whereas cotton (five layers), fiberglass medium (three layers), and the commercial absolute filter were at least 99.900, 99.999, and 99.999 efficient, respectively. Glass wool and cotton were not used under higher air-flow conditions because they were difficult to assemble in leak-tight filters. The commercial absolute filter and fiberglass medium (three layers) were at least 99.990 and 99.999% efficient, respectively, under the higher air flow conditions. A stainless-steel filter of simple design and fitted with three layers of fiberglass medium was found to be greater than 99.999% efficient in removing high concentrations (20,000 to 70,000 plaque-forming units per cubic foot) of aerosolized bacteriophages from air moving at a low flow rate (1 ft3/min). Use of this filter on pressure-vacuum tanks in the fermentation industry is suggested. Several other uses of such a filter are proposed. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 PMID:5927020

  7. Flowrate testing of the bag filter LANCS-BOP 6CPVC-1.5-2SPVC (LANCS Industries) at 1 psig

    SciTech Connect

    Moore, Murray E.; Currie, Karissa Lyn; Berg, Charlotte Katherine

    2016-09-13

    The air flowrate through a flexible HEPA grade filter (Part LANCS-BOP 6CPVC-1.5-2SPVC www.lancsindustries.com) was measured at 48 ALPM for a differential pressure drop of 1.0 psig (28 inWC, 7.0 kPa). These filters are rated by the manufacturer to have a flowrate of 3 ALPM at a differential pressure drop of 1 inWC (0.25 kPa). The Los Alamos National Laboratory Aerosol Engineering Facility used one of their test rigs (originally developed to measure the pressure drop in capsule HEPA filters) to measure the airflow through the LANCS bag filter.

  8. Independent Evaluation of Air Filter Media from Chornobyl

    SciTech Connect

    MD Hoover; AF Fencl; GJ Vargo

    1999-12-21

    An independent evaluation was performed to assess the morphology, pressure drop characteristics, alpha spectroscopy characteristics, and collection efficiency of an air sampling filter media and two types of aerosol face masks provided from Chernobyl by Pacific Northwest National Laboratory. The evaluation included characterizing the filter morphology by scqg electron microscopy; measuring the filter pressure drop as a function of air flowrate; evaluating the spectroscopy characteristics of the filter for alpha-emitting radionuclides by sampling ambient radon progeny aerosols in an Eberline Alpha-6A alpha continuous air monitor; determining the particle collection efficiency of the filter media for 0.3 {micro}m aerodynamic diameter monodisperse particles at 1 and 2 cfm; and comparing the apparent construction, durability, and performance similarities of the filter media to other media commonly used for monitoring airborne alpha-emitting radionuclides.

  9. Are Ventilation Filters Degrading Indoor Air Quality in California Classrooms?

    SciTech Connect

    Fisk, William J.; Destaillats, H.; Apte, M.G.; Destaillats,, Hugo; Fisk, Michael G. Apte and William J.

    2008-10-01

    Heating, ventilating, and cooling classrooms in California consume substantial electrical energy. Indoor air quality (IAQ) in classrooms affects studenthealth and performance. In addition to airborne pollutants that are emitted directly by indoor sources and those generated outdoors, secondary pollutants can be formed indoors by chemical reaction of ozone with other chemicals and materials. Filters are used in nearly all classroom heating, ventilation and air?conditioning (HVAC) systems to maintain energy-efficient HVAC performance and improve indoor air quality; however, recent evidence indicates that ozone reactions with filters may, in fact, be a source of secondary pollutants. This project quantitatively evaluated ozone deposition in HVAC filters and byproduct formation, and provided a preliminary assessment of the extent towhich filter systems are degrading indoor air quality. The preliminary information obtained will contribute to the design of subsequent research efforts and the identification of energy efficient solutions that improve indoor air quality in classrooms and the health and performance of students.

  10. Spacelab J air filter debris analysis

    NASA Technical Reports Server (NTRS)

    Obenhuber, Donald C.

    1993-01-01

    Filter debris from the Spacelab module SLJ of STS-49 was analyzed for microbial contamination. Debris for cabin and avionics filters was collected by Kennedy Space Center personnel on 1 Oct. 1992, approximately 5 days postflight. The concentration of microorganisms found was similar to previous Spacelab missions averaging 7.4E+4 CFU/mL for avionics filter debris and 4.5E+6 CFU/mL for the cabin filter debris. A similar diversity of bacterial types was found in the two filters. Of the 13 different bacterial types identified from the cabin and avionics samples, 6 were common to both filters. The overall analysis of these samples as compared to those of previous missions shows no significant differences.

  11. Field evaluation of prototype electrofibrous filters

    SciTech Connect

    Kuhl, W.D.; Bergman, W.; Biermann, A.H.; Lum, B.Y.

    1982-09-30

    New prototype electrofibrous filters were designed, built and evaluated in laboratory tests and in field installations. Two prototypes were designed for use in nuclear ventilation ducts as prefilters to HEPA filters. One prototype is designed to be a permanent component of the ventilation system while the other is a disposable unit. The disposable electrofibrous prefilter was installed in the exhaust stream of a glove box in which barrels of uranium turnings are burned. Preliminary tests show the disposal prefilter is effectively prolonging the HEPA filter life. An earlier prototype of the rolling prefilter was upgraded to meet the increased requirements for installation in a nuclear facility. This upgraded prototype was evaluated in the fire test facility at LLNL and shown to be effective in protecting HEPA filters from plugging under the most severe smoke conditions. The last prototype described in this report is a recirculating air filter. After demonstrating a high performance in laboratory tests the unit was shipped to Savannah River where it is awaiting installation in a Pu fuel fabrication facility. An analysis of the particulate problem in Savannah River indicates that four recirculating air filter will save $172,000 per year in maintenance costs.

  12. Independent Evaluaton of Air Filter Media From Chornobyl

    SciTech Connect

    Hoover, Mark D.; Fencl, Alice F.; Vargo, George J.

    1999-09-10

    Independent Evaluation of Air Filter Media from Chornobyl Research performed for the U.S. Department of Energy under Cooperative Agreement DE-FC04-96AL76406 Edited by Lovelace Respiratory Research Institute

  13. Aircraft Recirculation Filter for Air-Quality and Incident Assessment

    PubMed Central

    Eckels, Steven J.; Jones, Byron; Mann, Garrett; Mohan, Krishnan R.; Weisel, Clifford P.

    2015-01-01

    The current research examines the possibility of using recirculation filters from aircraft to document the nature of air-quality incidents on aircraft. These filters are highly effective at collecting solid and liquid particulates. Identification of engine oil contaminants arriving through the bleed air system on the filter was chosen as the initial focus. A two-step study was undertaken. First, a compressor/bleed air simulator was developed to simulate an engine oil leak, and samples were analyzed with gas chromatograph-mass spectrometry. These samples provided a concrete link between tricresyl phosphates and a homologous series of synthetic pentaerythritol esters from oil and contaminants found on the sample paper. The second step was to test 184 used aircraft filters with the same gas chromatograph-mass spectrometry system; of that total, 107 were standard filters, and 77 were nonstandard. Four of the standard filters had both markers for oil, with the homologous series synthetic pentaerythritol esters being the less common marker. It was also found that 90% of the filters had some detectable level of tricresyl phosphates. Of the 77 nonstandard filters, 30 had both markers for oil, a significantly higher percent than the standard filters. PMID:25641977

  14. Methodology for Modeling the Microbial Contamination of Air Filters

    PubMed Central

    Joe, Yun Haeng; Yoon, Ki Young; Hwang, Jungho

    2014-01-01

    In this paper, we propose a theoretical model to simulate microbial growth on contaminated air filters and entrainment of bioaerosols from the filters to an indoor environment. Air filter filtration and antimicrobial efficiencies, and effects of dust particles on these efficiencies, were evaluated. The number of bioaerosols downstream of the filter could be characterized according to three phases: initial, transitional, and stationary. In the initial phase, the number was determined by filtration efficiency, the concentration of dust particles entering the filter, and the flow rate. During the transitional phase, the number of bioaerosols gradually increased up to the stationary phase, at which point no further increase was observed. The antimicrobial efficiency and flow rate were the dominant parameters affecting the number of bioaerosols downstream of the filter in the transitional and stationary phase, respectively. It was found that the nutrient fraction of dust particles entering the filter caused a significant change in the number of bioaerosols in both the transitional and stationary phases. The proposed model would be a solution for predicting the air filter life cycle in terms of microbiological activity by simulating the microbial contamination of the filter. PMID:24523908

  15. Magnetic analyses of powders from exhausted cabin air filters

    NASA Astrophysics Data System (ADS)

    Winkler, Aldo; Sagnotti, Leonardo

    2013-04-01

    The automotive cabin air filter is a pleated-paper filter placed in the outside-air intake for the car's passenger compartment. Dirty and saturated cabin air filters significantly reduce the airflow from the outside and introduce particulate matter (PM) and allergens (for example, pollen) into the cabin air stream. Magnetic measurements and analyses have been carried out on powders extracted from exhausted cabin air filters to characterize their magnetic properties and to compare them to those already reported for powders collected from disk brakes, gasoline exhaust pipes and Quercus ilex leaves. This study is also aimed at the identification and quantification of the contribution of the ultrafine fraction, superparamagnetic (SP) at room temperature, to the overall magnetic properties of these powders. This contribution was estimated by interpreting and comparing data from FORCs, isothermal remanent magnetization vs time decay curves, frequency and field dependence of the magnetic susceptibility and out-of-phase susceptibility. The magnetic properties and the distribution of the SP particles are generally homogenous and independent of the brand of the car, of the model of the filter and of its level of usage. The relatively high concentration of magnetic PM trapped in these filters poses relevant questions about the air quality inside a car.

  16. [A membrane filter sampling method for determining microbial air pollution].

    PubMed

    Cherneva, P; Kiranova, A

    1996-01-01

    The method is a contribution in the evaluation of the exposition and the control of the standards for organic powders. The method concerns the sample-taking procedure and the analysis-making technique for determining of the concentration of the microbial pollution of the air. It is based on filtering of some amount of air through a membrane filter which is then processed for cultivating of microbial colonies on its surface. The results are obtained in number of microbial colonies per unit of air. The method presents opportunity to select and vary the filtered volume of air, to determine the respirable fraction, to determine the personal exposition, as well as for the simultaneous determining of the microbial pollution together with other important parameters of the particle pollutants of the air (metal, fibre and others).

  17. Fungal colonization of air filters for use in heating, ventilating, and air conditioning (HVAC) systems.

    PubMed

    Simmons, R B; Crow, S A

    1995-01-01

    New and used cellulosic air filters for HVAC systems including those treated with antimicrobials were suspended in vessels with a range of relative humidities (55-99%) and containing non-sterile potting soil which stimulates fungal growth. Most filters yielded fungi prior to suspension in the chambers but only two of 14 nontreated filters demonstrated fungal colonization following use in HVAC systems. Filters treated with antimicrobials, particularly a phosphated amine complex, demonstrated markedly less fungal colonization than nontreated filters. In comparison with nontreated cellulosic filters, fungal colonization of antimicrobial-treated cellulosic filters was selective and delayed.

  18. HEPA/Vaccine Plan for Indoor Anthrax Remediation

    PubMed Central

    Liu, Yifan; Leighton, Terrance J.

    2005-01-01

    We developed a mathematical model to compare 2 indoor remediation strategies in the aftermath of an outdoor release of 1.5 kg of anthrax spores in lower Manhattan. The 2 strategies are the fumigation approach used after the 2001 postal anthrax attack and a HEPA/vaccine plan, which relies on HEPA vacuuming, HEPA air cleaners, and vaccination of reoccupants. The HEPA/vaccine approach leads to few anthrax cases among reoccupants if applied to all but the most heavily contaminated buildings, and recovery is much faster than under the decades-long fumigation plan. Only modest environmental sampling is needed. A surge capacity of 10,000 to 20,000 Hazmat workers is required to perform remediation within 6 to 12 months and to avoid permanent mass relocation. Because of the possibility of a campaign of terrorist attacks, serious consideration should be given to allowing or encouraging voluntary self-service cleaning of lightly contaminated rooms by age-appropriate, vaccinated, partially protected (through masks or hoods) reoccupants or owners. PMID:15705325

  19. Environmental control: operating room air quality.

    PubMed

    Bartley, J M

    1993-01-01

    1. OR staff members should familiarize themselves with basic air handling system terminology to better manage their own environment (eg, HVAC, air changes, air balancing, HEPA filtration). A working relationship with building engineers is an important skill for the OR nurse. 2. Knowledge of the standards on which air quality in the OR is based should assist in the process of planning for improved design--as well as in monitoring existing air quality. 3. Current standards balance energy savings with air changes and high levels of filtration to achieve optimum outcomes. Recommendations from design and engineering authorities (even for implant surgery) are based on average air changes and HEPA filtration, not laminar air flow. 4. The daily, operational role of the OR staff in maintaining high air quality includes managing traffic, using low-lint barrier materials, monitoring air quality indicators, and investigating unusual variances with the engineering staff for appropriate follow-up (eg, filter changes).

  20. Fuel cell cathode air filters: Methodologies for design and optimization

    NASA Astrophysics Data System (ADS)

    Kennedy, Daniel M.; Cahela, Donald R.; Zhu, Wenhua H.; Westrom, Kenneth C.; Nelms, R. Mark; Tatarchuk, Bruce J.

    Proton exchange membrane (PEM) fuel cells experience performance degradation, such as reduction in efficiency and life, as a result of poisoning of platinum catalysts by airborne contaminants. Research on these contaminant effects suggests that the best possible solution to allowing fuel cells to operate in contaminated environments is by filtration of the harmful contaminants from the cathode air. A cathode air filter design methodology was created that connects properties of cathode air stream, filter design options, and filter footprint, to a set of adsorptive filter parameters that must be optimized to efficiently operate the fuel cell. Filter optimization requires a study of the trade off between two causal factors of power loss: first, a reduction in power production due to poisoning of the platinum catalyst by chemical contaminants and second, an increase in power requirements to operate the air compressor with a larger pressure drop from additional contaminant filtration. The design methodology was successfully applied to a 1.2 kW fuel cell using a programmable algorithm and predictions were made about the relationships between inlet concentration, breakthrough time, filter design, pressure drop, and compressor power requirements.

  1. Effect of Intake Air Filter Condition on Vehicle Fuel Economy

    SciTech Connect

    Norman, Kevin M; Huff, Shean P; West, Brian H

    2009-02-01

    The U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy and the U.S. Environmental Protection Agency (EPA) jointly maintain a fuel economy website (www.fueleconomy.gov), which helps fulfill their responsibility under the Energy Policy Act of 1992 to provide accurate fuel economy information [in miles per gallon (mpg)] to consumers. The site provides information on EPA fuel economy ratings for passenger cars and light trucks from 1985 to the present and other relevant information related to energy use such as alternative fuels and driving and vehicle maintenance tips. In recent years, fluctuations in the price of crude oil and corresponding fluctuations in the price of gasoline and diesel fuels have renewed interest in vehicle fuel economy in the United States. (User sessions on the fuel economy website exceeded 20 million in 2008 compared to less than 5 million in 2004 and less than 1 million in 2001.) As a result of this renewed interest and the age of some of the references cited in the tips section of the website, DOE authorized the Oak Ridge National Laboratory (ORNL) Fuels, Engines, and Emissions Research Center (FEERC) to initiate studies to validate and improve these tips. This report documents a study aimed specifically at the effect of engine air filter condition on fuel economy. The goal of this study was to explore the effects of a clogged air filter on the fuel economy of vehicles operating over prescribed test cycles. Three newer vehicles (a 2007 Buick Lucerne, a 2006 Dodge Charger, and a 2003 Toyota Camry) and an older carbureted vehicle were tested. Results show that clogging the air filter has no significant effect on the fuel economy of the newer vehicles (all fuel injected with closed-loop control and one equipped with MDS). The engine control systems were able to maintain the desired AFR regardless of intake restrictions, and therefore fuel consumption was not increased. The carbureted engine did show a decrease in

  2. Electric air filtration: theory, laboratory studies, hardware development, and field evaluations

    SciTech Connect

    Bergman, W.; Biermann, A.; Kuhl, W.; Lum, B.; Bogdanoff, A.; Hebard, H.; Hall, M.; Banks, D.; Mazumder, M.; Johnson, J.

    1983-09-01

    We summarize the results of a seven-year research project for the US Department of Energy (DOE) to develop electric air filters that extend the service life of high-efficiency particulate air (HEPA) filters used in the nuclear industry. This project was unique to Lawrence Livermore National Laboratory (LLNL), and it entailed comprehensive theory, laboratory studies, and hardware development. We present our work in three major areas: (1) theory of and instrumentation for filter test methods, (2) theoretical and laboratory studies of electric air filters, and (3) development and evaluation of eight experimental electric air filters.

  3. Comparison of aerosol and bioaerosol collection on air filters.

    PubMed

    Miaskiewicz-Peska, Ewa; Lebkowska, Maria

    2012-06-01

    Air filters efficiency is usually determined by non-biological test aerosols, such as potassium chloride particles, Arizona dust or di-ethyl-hexyl-sebacate (DEHS) oily liquid. This research was undertaken to asses, if application of non-biological aerosols reflects air filters capacity to collect particles of biological origin. The collection efficiency for non-biological aerosol was tested with the PALAS set and ISO Fine Test Dust. Flow rate during the filtration process was 720 l/h, and particles size ranged 0.246-17.165 μm. The upstream and downstream concentration of the aerosol was measured with a laser particle counter PCS-2010. Tested bioaerosol contained 4 bacterial strains of different shape and size: Micrococcus luteus,Micrococcus varians, Pseudomonas putida and Bacillus subtilis. Number of the biological particles was estimated with a culture-based method. Results obtained with bioaerosol did not confirmed 100% filters efficiency noted for the mineral test dust of the same aerodynamic diameter. Maximum efficiency tested with bacterial cells was 99.8%. Additionally, cells reemission from filters into air was also studied. Bioaerosol contained 3 bacterial strains: Micrococcus varians, Pseudomonas putida and Bacillus subtilis. It was proved that the highest intensity of the reemission process was during the first 5 min. and reached maximum 0.63% of total number of bacteria retained in filters. Spherical cells adhered stronger to the filter fibres than cylindrical ones. It was concluded that non-biological aerosol containing particles of the same shape and surface characteristics (like DEHS spherical particles) can not give representative results for all particles present in the filtered air.

  4. Air-conditioner filters enriching dust mites allergen.

    PubMed

    Zhan, Xiaodong; Li, Chaopin; Xu, Haifeng; Xu, Pengfei; Zhu, Haibin; Diao, Jidong; Li, Na; Zhao, Beibei

    2015-01-01

    We detected the concentration of dust mites allergen (Der f1 & Der p1) in the air of different places before and after the starting of air-conditioners in Wuhu City, Anhui, China, and to discuss the relation between the dust mites allergen in air-conditioner filters and the asthma attack. The dust samples were collected from the air-conditioner filters in dining rooms, shopping malls, hotels and households respectively. Concentrations of dust mites major group allergen 1 (Der f 1, Der p1) were detected with enzyme linked immunosorbent assay (ELISA), and the dust mite immune activities were determined by dot-ELISA. The concentration of Der f1 in dining rooms, shopping malls, hotels and households was 1.52 μg/g, 1.24 μg/g, 1.31 μg/g and 1.46 μg/g respectively, and the concentration of Der p1 in above-mentioned places was 1.23 μg/g, 1.12 μg/g, 1.16 μg/g and 1.18 μg/g respectively. The concentration of Der f1 & Der p1 in air was higher after the air-conditioners starting one hours later, and the difference was significant (P<0.05, respectively). Additionally, dot-ELISA findings revealed that the allergen extracted from the dust was capable of reacting with IgE from the sera of asthma mice allergic to dust mites. The study concludes that air-conditioner filters can enrich dust mites major group allergen, and the allergens can induce asthma. The air-conditioner filters shall be cleaned or replaced regularly to prevent or reduce accumulation of the dust mites and its allergens.

  5. 36. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" AIR FILTERS LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" AIR FILTERS LOOKING SOUTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  6. BIOLOGICAL WASTE AIR TREATMENT IN BIOTRICKLING FILTERS. (R825392)

    EPA Science Inventory

    Abstract

    Recent studies in the area of biological waste air treatment in biotrickling filters have addressed fundamental key issues, such as biofilm architecture, microbiology of the process culture and means to control accumulation of biomass. The results from these s...

  7. RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY AIR FILTER SAMPLES

    SciTech Connect

    Maxwell, S.; Noyes, G.; Culligan, B.

    2010-02-03

    A new rapid method for the determination of actinides and strontium in air filter samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations. The actinides and strontium in air filter method utilizes a rapid acid digestion method and a streamlined column separation process with stacked TEVA, TRU and Sr Resin cartridges. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha emitters are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The purified {sup 90}Sr fractions are mounted directly on planchets and counted by gas flow proportional counting. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency air filter samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinide and {sup 90}Sr in air filter results were reported in {approx}4 hours with excellent quality.

  8. Hybrid Filter Membrane

    NASA Technical Reports Server (NTRS)

    Laicer, Castro; Rasimick, Brian; Green, Zachary

    2012-01-01

    Cabin environmental control is an important issue for a successful Moon mission. Due to the unique environment of the Moon, lunar dust control is one of the main problems that significantly diminishes the air quality inside spacecraft cabins. Therefore, this innovation was motivated by NASA s need to minimize the negative health impact that air-suspended lunar dust particles have on astronauts in spacecraft cabins. It is based on fabrication of a hybrid filter comprising nanofiber nonwoven layers coated on porous polymer membranes with uniform cylindrical pores. This design results in a high-efficiency gas particulate filter with low pressure drop and the ability to be easily regenerated to restore filtration performance. A hybrid filter was developed consisting of a porous membrane with uniform, micron-sized, cylindrical pore channels coated with a thin nanofiber layer. Compared to conventional filter media such as a high-efficiency particulate air (HEPA) filter, this filter is designed to provide high particle efficiency, low pressure drop, and the ability to be regenerated. These membranes have well-defined micron-sized pores and can be used independently as air filters with discreet particle size cut-off, or coated with nanofiber layers for filtration of ultrafine nanoscale particles. The filter consists of a thin design intended to facilitate filter regeneration by localized air pulsing. The two main features of this invention are the concept of combining a micro-engineered straight-pore membrane with nanofibers. The micro-engineered straight pore membrane can be prepared with extremely high precision. Because the resulting membrane pores are straight and not tortuous like those found in conventional filters, the pressure drop across the filter is significantly reduced. The nanofiber layer is applied as a very thin coating to enhance filtration efficiency for fine nanoscale particles. Additionally, the thin nanofiber coating is designed to promote capture of

  9. [Sick building syndrome and HVAC system: MVOC from air filters].

    PubMed

    Schleibinger, H W; Wurm, D; Möritz, M; Böck, R; Rüden, H

    1997-08-01

    Growth and emissions of volatile metabolites of microorganisms on air filters are suspected to contribute to health complaints in ventilated rooms. To prove the microbiological production of volatile organic compounds (MVOC), concentrations of aldehydes and ketones were determined in two large HVAC systems. The in situ derivated aldehydes and ketones (as 2,4-dinitrophenyl-hydrazones) were analysed by HPLC and UV detection. The detection limit of each compound was 1 ppb (margin of error < 10%). Field measurements were carried out before and after the prefilters and the main filters, respectively, to investigate whether aldehydes and ketones increase in concentration after filters of HVAC systems. First results show that the compounds formaldehyde, acetaldehyde and acetone could be detected before and after the filters. The concentrations of these VOC after the filters were significantly increased--as a mean over twenty measurements--, especially as far as filters made of glass fibre are concerned. However the found concentrations were low and mostly comparable to outdoor findings. In simultaneous laboratory experiments pieces of used filter material of one HVAC system and unused filter pieces (for blank values) were examined in small incubation chambers to investigate the possible production of MVOC. For the incubation a temperature of 20 degrees C and a relative humidity of 95% was chosen. In these experiments an almost identical spectrum of compounds (formaldehyde and acetone) was found as in the field measurements. The concentrations of these compounds were higher in the chambers with the used filter pieces. The concentration of acetone ranged up to almost 12 mg/m3.--As our field experiments correspond with our laboratory experiments, we assume that the microbial production of volatile organic compounds in HVAC systems under operating conditions is possible.

  10. COMPUTATIONS ON THE PERFORMANCE OF PARTICLE FILTERS AND ELECTRONIC AIR CLEANERS

    EPA Science Inventory

    The paper discusses computations on the performance of particle filters and electronic air cleaners (EACs). The collection efficiency of particle filters and ACs is calculable if certain factors can be assumed or calibrated. For fibrous particulate filters, measurement of colle...

  11. Give reverse-air fabric filters a closer look

    SciTech Connect

    Jensen, R.M.

    1995-02-01

    Although use of reverse-air filters dominates in operating US utility power stations, pulse-jet designs seem to be getting the lion`s share of attention for new and retrofit plants. This article examines key technical advantages of reverse-air designs that are becoming lost in the current debate. Control of particulate emissions continues to be an area of growing concern for operators of coal-fired powerplants, especially as it relates to air toxics and fine particulates. That concern has led to greater scrutiny of the devices used to control those emissions. Regarding the fabric-filter option, reverse-air (RA) designs have operated reliably at large utility units, but now face a strong challenge from pulse-jet (PJ) designs--which are more popular with operators of independent-power-producer, waste-to-energy, and other small solid-fuel-fired units. Both RA and PJ designs can adequately meet the particulate emissions requirements for large coal-fired units when properly applied. The wholesale shift by electric utilities from RA to PJ fabric filters--at least in discussion if not actual projects--is apparent but may be short-sighted. The oft-stated reason--that RA fabric filters can only handle a face velocity one-half that of PJ, resulting in higher cost for the RA option--is too simplistic. The many design and operating characteristics that distinguish the two should be thoroughly reviewed before blanket acceptance of PJ technology. Some of the technical areas reviewed here are level of commercial design experience, bag life, pressure drop, bag replacement procedure, cleaning cycles, particle elutriation, submicron-particle floaters, residual-cake preservation, and particle re-entrainment.

  12. DWPF GC FILTER ASSEMBLY SAMPLING AND ANALYSIS

    SciTech Connect

    Bannochie, C.; Imrich, K.

    2009-11-11

    On March 18, 2009 a Defense Waste Processing Facility (DWPF) GC Line Filter Assembly was received at the Savannah River National Laboratory (SRNL). This filter assembly was removed from operation following the completion of Sludge Batch 4 processing in the DWPF. Work on this sample was requested in a Technical Assistance Request. This document reports the pictures, observations, samples collected, and analytical results for the assembly. The assembly arrived at SRNL separated into its three component filters: high efficiency particulate air (HEPA)-1, HEPA-2, and a high efficiency mist evaporator (HEME). Each stage of the assembly's media was sampled and examined visually and by scanning electron microscopy (SEM). Solids built up in the filter housing following the first stage HEME, were dissolved in dilute nitric acid and analyzed by ICP-AES and the undissolved white solids were analyzed by x-ray diffraction (XRD). The vast majority of the material in each of the three stages of the DWPF GC Line Filter Assembly appears to be contaminated with a Hg compound that is {approx}59 wt% Hg on a total solids basis. The Hg species was identified by XRD analysis to contain a mixture of Hg{sub 4}(OH)(NO{sub 3}){sub 3} and Hg{sub 10}(OH){sub 4}(NO{sub 3}){sub 6}. Only in the core sample of the second stage HEPA, did this material appear to be completely covering portions of the filter media, possibly explaining the pressure drops observed by DWPF. The fact that the material migrates through the HEME filter and both HEPA filters, and that it was seen collecting on the outlet side of the HEME filter, would seem to indicate that these filters are not efficient at removing this material. Further SRAT off-gas system modeling should help determine the extent of Hg breakthrough past the Mercury Water Wash Tank (MWWT). The SRAT off-gas system has not been modeled since startup of the facility. Improvements to the efficiency of Hg stripping prior to the ammonia scrubber would seem to be

  13. Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)

    NASA Technical Reports Server (NTRS)

    Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.

    1974-01-01

    The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.

  14. Development of Test Protocols for International Space Station Particulate Filters

    NASA Technical Reports Server (NTRS)

    Green, Robert D.; Vijayakumar, R.; Agui, Juan H.

    2014-01-01

    Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High- Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. Over the years, the service life of these filters has been re-evaluated based on limited post-flight tests of returned filters and risk factors. On earth, a well designed and installed HEPA filter will last for several years, e.g. in industrial and research clean room applications. Test methods for evaluating these filters are being developed on the basis of established test protocols used by the industry and the military. This paper will discuss the test methods adopted and test results on prototypes of the ISS filters. The results will assist in establishing whether the service life can be extended for these filters. Results from unused filters that have been in storage will also be presented to ascertain the shelf life and performance deterioration, if any and determine if the shelf life may be extended.

  15. Leaks in nuclear grade high efficiency aerosol filters

    SciTech Connect

    Scripsick, Ronald Clyde

    1994-07-01

    Nuclear grade high efficiency aerosol filters, also known as high efficiency particulate air (HEPA) filters, are commonly used in air cleaning systems for removal of hazardous aerosols. Performance of the filter units is important in assuring health and environmental protection. The filter units are constructed from pleated packs of fiberglass filter media sealed into rigid frames. Results of previous studies on such filter units indicate that their performance may not be completely predicted by ideal performance of the fibrous filter media. In this study, departure from ideal performance is linked to leaks existing in filter units and overall filter unit performance is derived from independent performance of the individual filter unit components. The performance of 14 nuclear grade HEPA filter units (size 1, 25 cfm) with plywood frames was evaluated with a test system that permitted independent determination of penetration as a function of particle size for the whole filter unit, the filter unit frame, and the filter media pack. Tests were performed using a polydisperse aerosol of di-2-ethylhexyl phthalate with a count median diameter of 0.2 {mu}m and geometric standard deviation of 1.6. Flow rate and differential pressure were controlled from 1% to 100% of design values. Particle counts were made upstream and downstream of the filter unit with an optical particle counter (OPC). The OPC provided count information in 28 size channels over the particle diameter range from 0.1 to 0.7 μm. Results provide evidence for a two component leak model of filler unit performance with: (1) external leaks through filter unit frames, and (2) internal leaks through defects in the media and through the seal between the media pack and frame. For the filter units evaluated, these leaks dominate overall filter unit performance over much of the flow rate and particle size ranges tested.

  16. Air filtering capacity of an integrated cardiopulmonary bypass unit.

    PubMed

    Mueller, Xavier M; Tevaearai, Hendrik T; Jegger, David; von Segesser, Ludwig K

    2003-01-01

    To limit the morbidity of cardiopulmonary bypass (CPB), a new concept of integrating pumping, oxygenation, and air removal into a single unit has been developed (CardioVention Inc., Santa Clara, CA). The air filtration capacity of this system was tested. Three calves (73.2 +/- 2 kg) were connected to the integrated system by jugular and carotid cannulation. The integrated unit was challenged with injections of boluses of air of 5, 10, and 20 ml, three times each, and for a blood flow of 3 L/min and 5 L/min, respectively. The bubble count and size were recorded downstream of the unit with a Doppler ultrasound. At 3 L/min, bubbles were detected after injections of 20 ml only (n = 7 for the nine boluses). At 5 L/min, 1 bubble was detected with the nine injections of 5 ml, 14 bubbles were detected with nine injections of 10 ml, and 25 bubbles were detected with nine injections of 20 ml. No bubble exceeded 40 microm in diameter as determined by the Doppler ultrasound. The air filtering capacity of the CardioVention system is excellent both in terms of bubble count and of size after injection of large boluses of air. Its integrated concept offers a simplification of the circuit with fewer devices and connections, which further reduces the risk of accidental air introduction.

  17. Transparent air filter for high-efficiency PM2.5 capture.

    PubMed

    Liu, Chong; Hsu, Po-Chun; Lee, Hyun-Wook; Ye, Meng; Zheng, Guangyuan; Liu, Nian; Li, Weiyang; Cui, Yi

    2015-02-16

    Particulate matter (PM) pollution has raised serious concerns for public health. Although outdoor individual protection could be achieved by facial masks, indoor air usually relies on expensive and energy-intensive air-filtering devices. Here, we introduce a transparent air filter for indoor air protection through windows that uses natural passive ventilation to effectively protect the indoor air quality. By controlling the surface chemistry to enable strong PM adhesion and also the microstructure of the air filters to increase the capture possibilities, we achieve transparent, high air flow and highly effective air filters of ~90% transparency with >95.00% removal of PM2.5 under extreme hazardous air-quality conditions (PM2.5 mass concentration >250 μg m(-3)). A field test in Beijing shows that the polyacrylonitrile transparent air filter has the best PM2.5 removal efficiency of 98.69% at high transmittance of ~77% during haze occurrence.

  18. Transparent air filter for high-efficiency PM2.5 capture

    NASA Astrophysics Data System (ADS)

    Liu, Chong; Hsu, Po-Chun; Lee, Hyun-Wook; Ye, Meng; Zheng, Guangyuan; Liu, Nian; Li, Weiyang; Cui, Yi

    2015-02-01

    Particulate matter (PM) pollution has raised serious concerns for public health. Although outdoor individual protection could be achieved by facial masks, indoor air usually relies on expensive and energy-intensive air-filtering devices. Here, we introduce a transparent air filter for indoor air protection through windows that uses natural passive ventilation to effectively protect the indoor air quality. By controlling the surface chemistry to enable strong PM adhesion and also the microstructure of the air filters to increase the capture possibilities, we achieve transparent, high air flow and highly effective air filters of ~90% transparency with >95.00% removal of PM2.5 under extreme hazardous air-quality conditions (PM2.5 mass concentration >250 μg m-3). A field test in Beijing shows that the polyacrylonitrile transparent air filter has the best PM2.5 removal efficiency of 98.69% at high transmittance of ~77% during haze occurrence.

  19. Air gap resonant tunneling bandpass filter and polarizer.

    PubMed

    Melnyk, A; Bitarafan, M H; Allen, T W; DeCorby, R G

    2016-04-15

    We describe a bandpass filter based on resonant tunneling through an air layer in the frustrated total internal reflection regime, and show that the concept of induced transmission can be applied to the design of thin film matching stacks. Experimental results are reported for Si/SiO2-based devices exhibiting a polarization-dependent passband, with bandwidth on the order of 10 nm in the 1550 nm wavelength range, peak transmittance on the order of 80%, and optical density greater than 5 over most of the near infrared region.

  20. Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems.

    PubMed

    Möritz, M; Peters, H; Nipko, B; Rüden, H

    2001-07-01

    The capability of air filters (filterclass: F6, F7) to retain airborne outdoor microorganisms was examined in field experiments in two heating, ventilating and air conditioning (HVAC) systems. At the beginning of the 15-month investigation period, the first filter stages of both HVAC systems were equipped with new unused air filters. The number of airborne bacteria and molds before and behind the filters were determined simultaneously in 14 days-intervals using 6-stage Andersen cascade impactors. Under relatively dry (< 80% R. H.) and warm (> 12 degrees C) outdoor air conditions air filters led to a marked reduction of airborne microorganism concentrations (bacteria by approximately 70% and molds by > 80%). However, during long periods of high relative humidity (> 80% R. H.) a proliferation of bacteria on air filters with subsequent release into the filtered air occurred. These microorganisms were mainly smaller than 1.1 microns therefore being part of the respirable fraction. The results showed furthermore that one possibility to avoid microbial proliferation is to limit the relative humidity in the area of the air filters to 80% R. H. (mean of 3 days), e.g. by using preheaters in front of air filters in HVAC-systems.

  1. Evaluation of membrane filter field monitors for microbiological air sampling

    NASA Technical Reports Server (NTRS)

    Fields, N. D.; Oxborrow, G. S.; Puleo, J. R.; Herring, C. M.

    1974-01-01

    Due to area constraints encountered in assembly and testing areas of spacecraft, the membrane filter field monitor (MF) and the National Aeronautics and Space Administration-accepted Reyniers slit air sampler were compared for recovery of airborne microbial contamination. The intramural air in a microbiological laboratory area and a clean room environment used for the assembly and testing of the Apollo spacecraft was studied. A significantly higher number of microorganisms was recovered by the Reyniers sampler. A high degree of consistency between the two sampling methods was shown by a regression analysis, with a correlation coefficient of 0.93. The MF samplers detected 79% of the concentration measured by the Reyniers slit samplers. The types of microorganisms identified from both sampling methods were similar.

  2. Air Cleaning Technologies

    PubMed Central

    2005-01-01

    Executive Summary Objective This health technology policy assessment will answer the following questions: When should in-room air cleaners be used? How effective are in-room air cleaners? Are in-room air cleaners that use combined HEPA and UVGI air cleaning technology more effective than those that use HEPA filtration alone? What is the Plasmacluster ion air purifier in the pandemic influenza preparation plan? The experience of severe acute respiratory syndrome (SARS) locally, nationally, and internationally underscored the importance of administrative, environmental, and personal protective infection control measures in health care facilities. In the aftermath of the SARS crisis, there was a need for a clearer understanding of Ontario’s capacity to manage suspected or confirmed cases of airborne infectious diseases. In so doing, the Walker Commission thought that more attention should be paid to the potential use of new technologies such as in-room air cleaning units. It recommended that the Medical Advisory Secretariat of the Ontario Ministry of Health and Long-Term Care evaluate the appropriate use and effectiveness of such new technologies. Accordingly, the Ontario Health Technology Advisory Committee asked the Medical Advisory Secretariat to review the literature on the effectiveness and utility of in-room air cleaners that use high-efficiency particle air (HEPA) filters and ultraviolet germicidal irradiation (UVGI) air cleaning technology. Additionally, the Ontario Health Technology Advisory Committee prioritized a request from the ministry’s Emergency Management Unit to investigate the possible role of the Plasmacluster ion air purifier manufactured by Sharp Electronics Corporation, in the pandemic influenza preparation plan. Clinical Need Airborne transmission of infectious diseases depends in part on the concentration of breathable infectious pathogens (germs) in room air. Infection control is achieved by a combination of administrative, engineering

  3. Results from Evaluation of Proposed ASME AG-1 Section FI Metal Media Filters - 13063

    SciTech Connect

    Wilson, John A.; Giffin, Paxton K.; Parsons, Michael S.; Waggoner, Charles A.

    2013-07-01

    High efficiency particulate air (HEPA) filtration technology is commonly used in Department of Energy (DOE) facilities that require control of radioactive particulate matter (PM) emissions due to treatment or management of radioactive materials. Although HEPA technology typically makes use of glass fiber media, metal and ceramic media filters are also capable of filtering efficiencies beyond the required 99.97%. Sintered metal fiber filters are good candidates for use in DOE facilities due to their resistance to corrosive environments and resilience at high temperature and elevated levels of relative humidity. Their strength can protect them from high differential pressure or pressure spikes and allow for back pulse cleaning, extending filter lifetime. Use of these filters has the potential to reduce the cost of filtration in DOE facilities due to life cycle cost savings. ASME AG-1 section FI has not been approved due to a lack of protocols and performance criteria for qualifying section FI filters. The Institute for Clean Energy Technology (ICET) with the aid of the FI project team has developed a Section FI test stand and test plan capable of assisting in the qualification ASME AG-1 section FI filters. Testing done at ICET using the FI test stand evaluates resistance to rated air flow, test aerosol penetration and resistance to heated air of the section FI filters. Data collected during this testing consists of temperature, relative humidity, differential pressure, flow rate, upstream particle concentration, and downstream particle concentration. (authors)

  4. Magnetic evaluation of TSP-filters for air quality monitoring

    NASA Astrophysics Data System (ADS)

    Castañeda-Miranda, Ana Gabriela; Böhnel, Harald N.; Molina-Garza, Roberto S.; Chaparro, Marcos A. E.

    2014-10-01

    We present the magnetic properties of the powders collected by high volume total suspended particle air samplers used to monitor atmospheric pollution in Santiago de Querétaro, a city of one million people in central Mexico. The magnetic measurements have been combined with scanning electron microscopy observations and analysis, in order to characterize the particles captured in the filters as natural and anthropogenic. The main goal of the study is to test if magnetic measurements on the sampled atmospheric dust can be effective, low-cost, proxy to qualitatively estimate the air quality, complementing the traditional analytical methods. The magnetic properties of the powder collected in the filters have been investigated measuring the low field magnetic susceptibility, hysteresis loops, thermomagnetic curves, and isothermal remanent magnetization. The rock magnetism data have been supplemented by energy-dispersive X-ray spectroscopy analysis and Raman spectroscopy. It was found that the main magnetic carrier is low-Ti magnetite in the PSD range with a contribution from SP particles, and small but significant contributions from hematite, maghemite and goethite particles. Total suspended particles in the atmosphere during the monitored days ranged between about 30 and 280 μg/m3. Magnetic susceptibility values are well correlated with the independently determined total suspended particles concentration (R = 0.93), but particle concentration does not correlate as well with IRM1T. This may be attributed to contributions from SP and paramagnetic particles to the susceptibility signal, but not to the remanence. The effects of climate in particle size, composition and concentration were considered in terms of precipitation and wind intensity, but they are actually minor. The main effect of climate appears to be the removal of SP particles during rainy days. There is a contribution to air pollution from natural mineral sources, which we attribute to low vegetation cover

  5. Can car air filters be useful as a sampling medium for air pollution monitoring purposes?

    PubMed

    Katsoyiannis, Athanasios; Birgul, Askin; Ratola, Nuno; Cincinelli, Alessandra; Sweetman, Andy J; Jones, Kevin C

    2012-11-01

    Urban air quality and real human exposure to chemical environmental stressors is an issue of high scientific and political interest. In an effort to find innovative and inexpensive means for air quality monitoring, the ability of car engine air filters (CAFs) to act as efficient samplers collecting street level air, to which people are exposed to, was tested. In particular, in the case of taxis, air filters are replaced after regular distances, the itineraries are almost exclusively urban, cruising mode is similar and, thus, knowledge of the air flow can provide with an integrated city air sample. The present pilot study focused on polycyclic aromatic hydrocarbons (PAHs), the most important category of organic pollutants associated with traffic emissions. Concentrations of ΣPAHs in CAFs ranged between 650 and 2900 μg CAF(-1), with benzo[b]fluoranthene, benzo[k]fluoranthene and indeno[123-cd]pyrene being the most abundant PAHs. Benzo[a]pyrene (BaP) ranged between 110 and 250 μg CAF(-1), accounting regularly for 5-15% of the total carcinogenic PAHs. The CAF PAH loads were used to derive road-level atmospheric PAH concentrations from a standard formula relating to the CAF air flow. Important parameters/assumptions for these estimates are the cruising speed and the exposure duration of each CAF. Based on information obtained from the garage experts, an average 'sampled air volume' of 48,750 m(3) per CAF was estimated, with uncertainty in this calculation estimated to be about a factor of 4 between the two extreme scenarios. Based on this air volume, ΣPAHs ranged between 13 and 56 ng m(-3) and BaP between 2.1 and 5.0 ng m(-3), suggesting that in-traffic BaP concentrations can be many times higher than the limit values set by the UK (0.25 ng m(-3)) and the European Union (1.0 ng m(-3)), or from active sampling stations normally cited on building roof tops or far from city centres. Notwithstanding the limitations of this approach, the very low cost, the continuous

  6. The use of Whatman-41 filters for high volume air sampling

    NASA Technical Reports Server (NTRS)

    Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.

    1975-01-01

    The feasibility of using W41 filter media on a routine TSP high-volume monitoring network was determined by comparison with glass fiber (GF) filtering. Results indicate that suspended particulate samples from GF filters averaged slightly, but not significantly, higher than those from Whatman-41 filters. Some extra handling procedures were required to avoid errors due to the hygroscopic nature of W41 filters; these added procedures are not overly burdensome, however, and they allow the performance of analytical work, thus extending the capabilities of high-volume sampling. It was demonstrated that W41 filters are practical for air quality monitoring and elemental analysis in environments similar to Cleveland's.

  7. Antimicrobial nanoparticle-coated electrostatic air filter with high filtration efficiency and low pressure drop.

    PubMed

    Sim, Kyoung Mi; Park, Hyun-Seol; Bae, Gwi-Nam; Jung, Jae Hee

    2015-11-15

    In this study, we demonstrated an antimicrobial nanoparticle-coated electrostatic (ES) air filter. Antimicrobial natural-product Sophora flavescens nanoparticles were produced using an aerosol process, and were continuously deposited onto the surface of air filter media. For the electrostatic activation of the filter medium, a corona discharge electrification system was used before and after antimicrobial treatment of the filter. In the antimicrobial treatment process, the deposition efficiency of S. flavescens nanoparticles on the ES filter was ~12% higher than that on the pristine (Non-ES) filter. In the evaluation of filtration performance using test particles (a nanosized KCl aerosol and submicron-sized Staphylococcus epidermidis bioaerosol), the ES filter showed better filtration efficiency than the Non-ES filter. However, antimicrobial treatment with S. flavescens nanoparticles affected the filtration efficiency of the filter differently depending on the size of the test particles. While the filtration efficiency of the KCl nanoparticles was reduced on the ES filter after the antimicrobial treatment, the filtration efficiency was improved after the recharging process. In summary, we prepared an antimicrobial ES air filter with >99% antimicrobial activity, ~92.5% filtration efficiency (for a 300-nm KCl aerosol), and a ~0.8 mmAq pressure drop (at 13 cm/s). This study provides valuable information for the development of a hybrid air purification system that can serve various functions and be used in an indoor environment.

  8. Preparation of Fiber Based Binder Materials to Enhance the Gas Adsorption Efficiency of Carbon Air Filter.

    PubMed

    Lim, Tae Hwan; Choi, Jeong Rak; Lim, Dae Young; Lee, So Hee; Yeo, Sang Young

    2015-10-01

    Fiber binder adapted carbon air filter is prepared to increase gas adsorption efficiency and environmental stability. The filter prevents harmful gases, as well as particle dusts in the air from entering the body when a human inhales. The basic structure of carbon air filter is composed of spunbond/meltblown/activated carbon/bottom substrate. Activated carbons and meltblown layer are adapted to increase gas adsorption and dust filtration efficiency, respectively. Liquid type adhesive is used in the conventional carbon air filter as a binder material between activated carbons and other layers. However, it is thought that the liquid binder is not an ideal material with respect to its bonding strength and liquid flow behavior that reduce gas adsorption efficiency. To overcome these disadvantages, fiber type binder is introduced in our study. It is confirmed that fiber type binder adapted air filter media show higher strip strength, and their gas adsorption efficiencies are measured over 42% during 60 sec. These values are higher than those of conventional filter. Although the differential pressure of fiber binder adapted air filter is relatively high compared to the conventional one, short fibers have a good potential as a binder materials of activated carbon based air filter.

  9. Experimental investigation of air pressure affecting filtration performance of fibrous filter sheet.

    PubMed

    Xu, Bin; Yu, Xiao; Wu, Ya; Lin, Zhongping

    2017-03-01

    Understanding the effect of air pressure on their filtration performance is important for assessing the effectiveness of fibrous filters under different practical circumstances. The effectiveness of three classes of air filter sheets were investigated in laboratory-based measurements at a wide range of air pressures (60-130 KPa). The filtration efficiency was found most sensitive to the air pressure change at smaller particle sizes. As the air pressure increased from 60 to 130 KPa, significant decrease in filtration efficiency (up to 15%) and increase in pressure drop (up to 90 Pa) were observed. The filtration efficiency of the filter sheet with largest fiber diameter and smallest solid volume fraction was affected most, while the pressure drop of the filter sheet with smallest fiber diameter and largest solid volume fraction was affected most. The effect of air pressure on the filtration efficiency was slightly larger at greater filter face air velocity. However, the effect of air pressure on the pressure drop was negligible. The filtration efficiency and pressure drop were explicitly expressed as functions of the air pressure. Two coefficients were empirically derived and successfully accounted for the effects of air pressure on filtration efficiency and pressure drop.

  10. Influence of air flow rate and backwashing on the hydraulic behaviour of a submerged filter.

    PubMed

    Cobos-Becerra, Yazmin Lucero; González-Martínez, Simón

    2013-01-01

    The aim of this study was to evaluate backwashing effects on the apparent porosity of the filter media and on the hydraulic behaviour of a pilot scale submerged filter, prior to biofilm colonization, under different hydraulic retention times, and different air flow rates. Tracer curves were analysed with two mathematical models for ideal and non-ideal flow (axial dispersion and Wolf and Resnick models). The filter media was lava stones sieved to 4.5 mm. Backwashing causes attrition of media particles, decreasing the void volume of the filter media and, consequently, the tracer flow is more uniform. The eroded media presented lower dead volumes (79% for the filter with aeration and 8% for the filter without aeration) compared with the new media (83% for the filter with aeration and 22% for the filter without aeration). The flow patterns of eroded and new media were different because the more regular shape of the particles decreases the void volume of the filter media. The dead volume is attributed, in the case of the filter with aeration, to the turbulence caused by the air bubbles that generate preferential channelling of the bulk liquid along the filter media, creating large zones of stagnant liquid and, for the filter without aeration, to the channels formed due to the irregular shaped media.

  11. Filter for on-line air monitor unaffected by radon progeny and method of using same

    DOEpatents

    Phillips, Terrance D.; Edwards, Howard D.

    1999-01-01

    An apparatus for testing air having contaminants and radon progeny therein. The apparatus includes a sampling box having an inlet for receiving the air and an outlet for discharging the air. The sampling box includes a filter made of a plate of sintered stainless steel. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough. A method of testing air having contaminants and radon progeny therein. The method includes providing a testing apparatus that has a sampling box with an inlet for receiving the air and an outlet for discharging the air, and has a sintered stainless steel filter disposed within said sampling box; drawing air from a source into the sampling box using a vacuum pump; passing the air through the filter; monitoring the contaminants trapped by the filter; and providing an alarm when a selected level of contaminants is reached. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough.

  12. METAL MEDIA FILTERS, AG-1 SECTION FI

    SciTech Connect

    Adamson, D.

    2012-05-23

    One application of metal media filters is in various nuclear air cleaning processes including applications for protecting workers, the public and the environment from hazardous and radioactive particles. To support this application the development of the ASME AG-1 FI Standard on Metal Media has been under way for more than ten years. Development of the proposed section has required resolving several difficult issues associated with operating conditions (media velocity, pressure drop, etc.), qualification testing, and quality acceptance testing. Performance characteristics of metal media are dramatically different than the glass fiber media with respect to parameters like differential pressures, operating temperatures, media strength, etc. These differences make existing data for a glass fiber media inadequate for qualifying a metal media filter for AG-1. In the past much work has been conducted on metal media filters at facilities such as Lawrence Livermore National Laboratory (LLNL) and Savannah River National Laboratory (SRNL) to qualify the media as High Efficiency Particulate Air (HEPA) Filters. Particle retention testing has been conducted at Oak Ridge Filter Test Facility and at Air Techniques International (ATI) to prove that the metal media meets or exceeds the 99.97% particle retention required for a HEPA Filter. Even with his testing, data was lacking to complete an AG-1 FI Standard on metal media. With funding secured by Mississippi State University (MSU) from National Nuclear Security Administration (NNSA), a research test stand is being designed and fabricated at MSU's Institute for Clean Energy Technology (ICET) Facility to obtain qualification data on metal media. This in turn will support required data needed for the FI Standard. The paper will discuss in detail how the test stand at MSU will obtain the necessary data to complete the FI Standard.

  13. VERIFICATION TESTING OF TECHNOLOGIES TO CLEAN OR FILTER VENTILATION AIR

    EPA Science Inventory

    Because of the importance of indoor air quality, Research Triangle Institute's Air Pollution Control Technology is adding indoor air products as a new technology category available for testing. This paper discusses RTI's participation in previous Environmental Technology Verifica...

  14. Functional performance testing of the universal super absorbing air filters FSU 70 „Air by Corneliu”

    NASA Astrophysics Data System (ADS)

    Raţiu, S.; Birtok-Băneasă, C.; Alexa, V.; Kiss, I.

    2015-06-01

    This paper presents the experimental methodology to carry out functional performance tests for an air filter with a particular design of its housing, generically named Universal super absorbing FSU 70 „Air by Corneliu”. The tests were carried out in the Internal Combustion Engines Laboratory, within the specialization "Road automotives" belonging to the Faculty of Engineering Hunedoara, component of “Politehnica” University of Timisoara. We present some comparative values of various operating parameters of the engine fitted, in the first measuring session, with the original filter, and then with the studied filter.

  15. Fungal spore concentrations in two haematopoietic stem cell transplantation (HSCT) units containing distinct air control systems.

    PubMed

    Brun, C P; Miron, D; Silla, L M R; Pasqualotto, A C

    2013-04-01

    Invasive fungal diseases have emerged as important causes of morbidity and mortality in haematological patients. In this study air samples were collected in two haematopoietic stem cell transplantation (HSCT) units, in which distinct air-control systems were in place. In hospital 1 no high-efficiency particulate air (HEPA) filter was available whereas in hospital 2 HSCT rooms were equipped with HEPA filters, with positive air pressure in relation to the corridor. A total of 117 samples from rooms, toilets and corridors were obtained during December 2009 to January 2011, using a six-stage Andersen sampler. In both hospitals, the concentration of potentially pathogenic fungi in the air was reduced in patients' rooms compared to corridors (P < 0·0001). Despite the presence of a HEPA filter in hospital 2, rooms in both hospitals showed similar concentrations of potentially pathogenic fungi (P = 0·714). These findings may be explained by the implementation of additional protective measures in hospital 1, emphasizing the importance of such measures in protected environments.

  16. Preliminary field evaluation of high efficiency steel filters

    SciTech Connect

    Bergman, W.; Larsen, G.; Lopez, R.

    1995-02-01

    We have conducted an evaluation of two high efficiency steel filters in the exhaust of an uranium oxide grit blaster at the Y-12 Plant in Oak Ridge Tennessee. The filters were installed in a specially designed filter housing with a reverse air-pulse cleaning system for automatically cleaning the filters in-place. Previous tests conducted on the same filters and housing at LLNL under controlled conditions using Arizona road dust showed good cleanability with reverse air pulses. Two high efficiency steel filters, containing 64 pleated cartridge elements housed in the standard 2` x 2` x 1` HEPA frame, were evaluated in the filter test housing using a 1,000 cfm slip stream containing a high concentration of depleted uranium oxide dust. One filter had the pleated cartridges manufactured to our specifications by the Pall Corporation and the other by Memtec Corporation. Test results showed both filters had a rapid increase in pressure drop with time, and reverse air pulses could not decrease the pressure drop. We suspected moisture accumulation in the filters was the problem since there were heavy rains during the evaluations, and the pressure drop of the Memtec filter decreased dramatically after passing clean, dry air through the filter and after the filter sat idle for one week. Subsequent laboratory tests on a single filter cartridge confirmed that water accumulation in the filter was responsible for the increase in filter pressure drop and the inability to lower the pressure drop by reverse air pulses. No effort was made to identify the source of the water accumulation and correct the problem because the available funds were exhausted.

  17. Biomass control in waste air biotrickling filters by protozoan predation

    SciTech Connect

    Cox, H.H.J.; Deshusses, M.A.

    1999-01-20

    Two protozoan species as well as an uncharacterized protozoan consortium were added to a toluene-degrading biotrickling filter to investigate protozoan predation as a means of biomass control. Wet biomass formation in 23.6-L reactors over a 77-day period was reduced from 13.875 kg in a control biotrickling filter to 11.795 kg in a biotrickling filter enriched with protozoa. The average toluene vapor elimination capacity at 1 g/m{sup 3} toluene and 64 m{sup 3}/(m{sup 3} {center_dot} h) was 31.1 g(m{sup 3} {center_dot} h) in the control and 32.2 g(m{sup 3} {center_dot} h) in the biotrickling filter enriched with protozoa. At higher toluene inlet concentrations, toluene degradation rates increased and were slightly higher in the biotrickling filter enriched with protozoa. The lower rate of biomass accumulation after the addition of protozoa was due to an increase of carbon mineralization. Apparent biomass yield coefficients in the control and enriched trickling filter were 0.72 and 0.59 g dry biomass/g toluene, respectively. The results show that protozoan predation may be a useful tool to control biomass in biotrickling filters, however, further stimulation of predation of the biomass immobilized in the reactor is required to ensure long-term stability of biotrickling filters.

  18. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - AIR PURATOR CORPORATION HUYGLAS 1405M FILTER SAMPLE

    EPA Science Inventory

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  19. EVALUATION OF THE FILTER PACK FOR LONG-DURATION SAMPLING OF AMBIENT AIR

    EPA Science Inventory

    A 14-week filter pack (FP) sampler evaluation field study was conducted at a site near Bondville, IL to investigate the impact of weekly sampling duration. Simultaneous samples were collected using collocated filter packs (FP) from two independent air quality monitoring networks...

  20. Effect of Intake Air Filter Condition on Light-Duty Gasoline Vehicles

    SciTech Connect

    Thomas, John F; Huff, Shean P; West, Brian H; Norman, Kevin M

    2012-01-01

    Proper maintenance can help vehicles perform as designed, positively affecting fuel economy, emissions, and the overall drivability. This effort investigates the effect of one maintenance factor, intake air filter replacement, with primary focus on vehicle fuel economy, but also examining emissions and performance. Older studies, dealing with carbureted gasoline vehicles, have indicated that replacing a clogged or dirty air filter can improve vehicle fuel economy and conversely that a dirty air filter can be significantly detrimental to fuel economy. The effect of clogged air filters on the fuel economy, acceleration and emissions of five gasoline fueled vehicles is examined. Four of these were modern vehicles, featuring closed-loop control and ranging in model year from 2003 to 2007. Three vehicles were powered by naturally aspirated, port fuel injection (PFI) engines of differing size and cylinder configuration: an inline 4, a V6 and a V8. A turbocharged inline 4-cylinder gasoline direct injection (GDI) engine powered vehicle was the fourth modern gasoline vehicle tested. A vintage 1972 vehicle equipped with a carburetor (open-loop control) was also examined. Results reveal insignificant fuel economy and emissions sensitivity of modern vehicles to air filter condition, but measureable effects on the 1972 vehicle. All vehicles experienced a measured acceleration performance penalty with clogged intake air filters.

  1. Ultrafine particle removal by residential heating, ventilating, and air-conditioning filters.

    PubMed

    Stephens, B; Siegel, J A

    2013-12-01

    This work uses an in situ filter test method to measure the size-resolved removal efficiency of indoor-generated ultrafine particles (approximately 7-100 nm) for six new commercially available filters installed in a recirculating heating, ventilating, and air-conditioning (HVAC) system in an unoccupied test house. The fibrous HVAC filters were previously rated by the manufacturers according to ASHRAE Standard 52.2 and ranged from shallow (2.5 cm) fiberglass panel filters (MERV 4) to deep-bed (12.7 cm) electrostatically charged synthetic media filters (MERV 16). Measured removal efficiency ranged from 0 to 10% for most ultrafine particles (UFP) sizes with the lowest rated filters (MERV 4 and 6) to 60-80% for most UFP sizes with the highest rated filter (MERV 16). The deeper bed filters generally achieved higher removal efficiencies than the panel filters, while maintaining a low pressure drop and higher airflow rate in the operating HVAC system. Assuming constant efficiency, a modeling effort using these measured values for new filters and other inputs from real buildings shows that MERV 13-16 filters could reduce the indoor proportion of outdoor UFPs (in the absence of indoor sources) by as much as a factor of 2-3 in a typical single-family residence relative to the lowest efficiency filters, depending in part on particle size.

  2. A review of potential alternatives for air cleaning at the Hanford Waste Vitrification Plant

    SciTech Connect

    Sehmel, G.A.

    1990-07-01

    Pacific Northwest Laboratory conducted this review in support of the Hanford Waste Vitrification Plant (HWVP) being designed by Fluor Daniel Inc. for the US Department of Energy (DOE). The literature on air cleaning systems is reviewed to identify potential air cleaning alternatives that might be included in the design of HWVP. An overview of advantages/disadvantages of the various air cleaning technologies follows. Information and references are presented for the following potential air cleaning alternatives: deep-bed glass-fiber filters (DBGF), high-efficiency particulate air filters (HEPA), remote modular filter systems, high-efficiency mist eliminators (HEME), electrostatic precipitators, and the sand filter. Selected information is summarized for systems in the United States, Belgium, Japan, and West Germany. This review addresses high-capacity air cleaning systems currently used in the nuclear industry and emphasizes recent developments. 10 refs., 9 figs., 3 tabs.

  3. Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2009-01-23

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level.

  4. PubMed search filters for the study of putative outdoor air pollution determinants of disease

    PubMed Central

    Curti, Stefania; Gori, Davide; Di Gregori, Valentina; Farioli, Andrea; Baldasseroni, Alberto; Fantini, Maria Pia; Christiani, David C; Violante, Francesco S; Mattioli, Stefano

    2016-01-01

    Objectives Several PubMed search filters have been developed in contexts other than environmental. We aimed at identifying efficient PubMed search filters for the study of environmental determinants of diseases related to outdoor air pollution. Methods We compiled a list of Medical Subject Headings (MeSH) and non-MeSH terms seeming pertinent to outdoor air pollutants exposure as determinants of diseases in the general population. We estimated proportions of potentially pertinent articles to formulate two filters (one ‘more specific’, one ‘more sensitive’). Their overall performance was evaluated as compared with our gold standard derived from systematic reviews on diseases potentially related to outdoor air pollution. We tested these filters in the study of three diseases potentially associated with outdoor air pollution and calculated the number of needed to read (NNR) abstracts to identify one potentially pertinent article in the context of these diseases. Last searches were run in January 2016. Results The ‘more specific’ filter was based on the combination of terms that yielded a threshold of potentially pertinent articles ≥40%. The ‘more sensitive’ filter was based on the combination of all search terms under study. When compared with the gold standard, the ‘more specific’ filter reported the highest specificity (67.4%; with a sensitivity of 82.5%), while the ‘more sensitive’ one reported the highest sensitivity (98.5%; with a specificity of 47.9%). The NNR to find one potentially pertinent article was 1.9 for the ‘more specific’ filter and 3.3 for the ‘more sensitive’ one. Conclusions The proposed search filters could help healthcare professionals investigate environmental determinants of medical conditions that could be potentially related to outdoor air pollution. PMID:28003291

  5. Fungal colonization of air filters and insulation in a multi-story office building: production of volatile organics

    NASA Technical Reports Server (NTRS)

    Ahearn, D. G.; Crow, S. A.; Simmons, R. B.; Price, D. L.; Mishra, S. K.; Pierson, D. L.

    1997-01-01

    Secondary air filters in the air-handling units on four floors of a multi-story office building with a history of fungal colonization of insulation within the air distribution system were examined for the presence of growing fungi and production of volatile organic compounds. Fungal mycelium and conidia of Cladosporium and Penicillium spp. were observed on insulation from all floors and both sides of the air filters from one floor. Lower concentrations of volatile organics were released from air filter medium colonized with fungi as compared with noncolonized filter medium. However, the volatiles from the colonized filter medium included fungal metabolites such as acetone and a carbonyl sulfide-like compound that were not released from noncolonized filter medium. The growth of fungi in air distribution systems may affect the content of volatile organics in indoor air.

  6. Antimicrobial Air Filters Using Natural Euscaphis japonica Nanoparticles

    PubMed Central

    Yun, Ji Ho; Lee, Jung Eun; Lee, Hee Ju; Nho, Chu Won; Bae, Gwi- Nam; Jung, Jae Hee

    2015-01-01

    Controlling bioaerosols has become more important with increasing participation in indoor activities. Treatments using natural-product nanomaterials are a promising technique because of their relatively low toxicity compared to inorganic nanomaterials such as silver nanoparticles or carbon nanotubes. In this study, antimicrobial filters were fabricated from natural Euscaphis japonica nanoparticles, which were produced by nebulizing E. japonica extract. The coated filters were assessed in terms of pressure drop, antimicrobial activity, filtration efficiency, major chemical components, and cytotoxicity. Pressure drop and antimicrobial activity increased as a function of nanoparticle deposition time (590, 855, and 1150 µg/cm2filter at 3-, 6-, and 9-min depositions, respectively). In filter tests, the antimicrobial efficacy was greater against Staphylococcus epidermidis than Micrococcus luteus; ~61, ~73, and ~82% of M. luteus cells were inactivated on filters that had been coated for 3, 6, and 9 min, respectively, while the corresponding values were ~78, ~88, and ~94% with S. epidermidis. Although statistically significant differences in filtration performance were not observed between samples as a function of deposition time, the average filtration efficacy was slightly higher for S. epidermidis aerosols (~97%) than for M. luteus aerosols (~95%). High-performance liquid chromatography (HPLC) and electrospray ionization-tandem mass spectrometry (ESI/MS) analyses confirmed that the major chemical compounds in the E. japonica extract were 1(ß)-O-galloyl pedunculagin, quercetin-3-O-glucuronide, and kaempferol-3-O-glucoside. In vitro cytotoxicity and disk diffusion tests showed that E. japonica nanoparticles were less toxic and exhibited stronger antimicrobial activity toward some bacterial strains than a reference soluble nickel compound, which is classified as a human carcinogen. This study provides valuable information for the development of a bioaerosol control

  7. Development and evaluation of a cleanable high efficiency steel filter

    SciTech Connect

    Bergman, W.; Larsen, G.; Weber, F.; Wilson, P.; Lopez, R.; Valha, G.; Conner, J.; Garr, J.; Williams, K.; Biermann, A.; Wilson, K.; Moore, P.; Gellner, C.; Rapchun, D. ); Simon, K.; Turley, J.; Frye, L.; Monroe, D. )

    1993-01-01

    We have developed a high efficiency steel filter that can be cleaned in-situ by reverse air pulses. The filter consists of 64 pleated cylindrical filter elements packaged into a 6l0 [times] 6l0 [times] 292 mm aluminum frame and has 13.5 m[sup 2] of filter area. The filter media consists of a sintered steel fiber mat using 2 [mu]m diameter fibers. We conducted an optimization study for filter efficiency and pressure drop to determine the filter design parameters of pleat width, pleat depth, outside diameter of the cylinder, and the total number of cylinders. Several prototype cylinders were then built and evaluated in terms of filter cleaning by reverse air pulses. The results of these studies were used to build the high efficiency steel filter. We evaluated the prototype filter for efficiency and cleanability. The DOP filter certification test showed the filter has a passing efficiency of 99.99% but a failing pressure drop of 0.80 kPa at 1,700 m[sup 3]/hr. Since we were not able to achieve a pressure drop less than 0.25 kPa, the steel filter does not meet all the criteria for a HEPA filter. Filter loading and cleaning tests using AC Fine dust showed the filter could be repeatedly cleaned by reverse air pulses. The next phase of the prototype evaluation consisted of installing the unit and support housing in the exhaust duct work of a uranium grit blaster for a field evaluation at the Y-12 Plant in Oak Ridge, TN. The grit blaster is used to clean the surface of uranium parts and generates a cloud of UO[sub 2] aerosols. We used a 1,700 m[sup 3]/hr slip stream from the 10,200 m[sup 3]/hr exhaust system.

  8. Development and evaluation of a cleanable high efficiency steel filter

    SciTech Connect

    Bergman, W.; Larsen, G.; Weber, F.; Wilson, P.; Lopez, R.; Valha, G.; Conner, J.; Garr, J.; Williams, K.; Biermann, A.; Wilson, K.; Moore, P.; Gellner, C.; Rapchun, D.; Simon, K.; Turley, J.; Frye, L.; Monroe, D.

    1993-01-01

    We have developed a high efficiency steel filter that can be cleaned in-situ by reverse air pulses. The filter consists of 64 pleated cylindrical filter elements packaged into a 6l0 {times} 6l0 {times} 292 mm aluminum frame and has 13.5 m{sup 2} of filter area. The filter media consists of a sintered steel fiber mat using 2 {mu}m diameter fibers. We conducted an optimization study for filter efficiency and pressure drop to determine the filter design parameters of pleat width, pleat depth, outside diameter of the cylinder, and the total number of cylinders. Several prototype cylinders were then built and evaluated in terms of filter cleaning by reverse air pulses. The results of these studies were used to build the high efficiency steel filter. We evaluated the prototype filter for efficiency and cleanability. The DOP filter certification test showed the filter has a passing efficiency of 99.99% but a failing pressure drop of 0.80 kPa at 1,700 m{sup 3}/hr. Since we were not able to achieve a pressure drop less than 0.25 kPa, the steel filter does not meet all the criteria for a HEPA filter. Filter loading and cleaning tests using AC Fine dust showed the filter could be repeatedly cleaned by reverse air pulses. The next phase of the prototype evaluation consisted of installing the unit and support housing in the exhaust duct work of a uranium grit blaster for a field evaluation at the Y-12 Plant in Oak Ridge, TN. The grit blaster is used to clean the surface of uranium parts and generates a cloud of UO{sub 2} aerosols. We used a 1,700 m{sup 3}/hr slip stream from the 10,200 m{sup 3}/hr exhaust system.

  9. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    SciTech Connect

    Barnett, J. Matthew

    2008-08-22

    Since the mid-1980s the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity of particulate radioactive air samples. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor® 3000) used at PNNL for self absorption effects. There were two methods used in the study, 1) to compare the radioactivity concentration by direct gas-flow proportional counting of the filter to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection and 2) to evaluate sample filters by high resolution visual/infrared microscopy to determine the depth of material loading on or in the filter fiber material. Sixty samples were selected from the archive for acid digestion in the first method and about 30 samples were selected for high resolution visual/infrared microscopy. Mass loading effects were also considered. From the sample filter analysis, large error is associated with the average self absorption factor, however, when the data is compared directly one-to-one, statistically, there appears to be good correlation between the two analytical methods. The mass loading of filters evaluated was <0.2 mg cm-2 and was also compared against other published results. The microscopy analysis shows the sample material remains on the top of the filter paper and does not imbed into the filter media. Results of the microscopy evaluation lead to the conclusion that there is not a mechanism for significant self absorption. The overall conclusion is that self-absorption is not a significant factor in the analysis of filters used at PNNL for radioactive air stack sampling of radionuclide particulates and that an applied correction factor is conservative in determining overall sample activity. A new self absorption factor of 1.0 is recommended.

  10. Sintered composite filter

    DOEpatents

    Bergman, W.

    1986-05-02

    A particulate filter medium formed of a sintered composite of 0.5 micron diameter quartz fibers and 2 micron diameter stainless steel fibers is described. Preferred composition is about 40 vol.% quartz and about 60 vol.% stainless steel fibers. The media is sintered at about 1100/sup 0/C to bond the stainless steel fibers into a cage network which holds the quartz fibers. High filter efficiency and low flow resistance are provided by the smaller quartz fibers. High strength is provided by the stainless steel fibers. The resulting media has a high efficiency and low pressure drop similar to the standard HEPA media, with tensile strength at least four times greater, and a maximum operating temperature of about 550/sup 0/C. The invention also includes methods to form the composite media and a HEPA filter utilizing the composite media. The filter media can be used to filter particles in both liquids and gases.

  11. Infiltration of forest fire and residential wood smoke: an evaluation of air cleaner effectiveness.

    PubMed

    Barn, Prabjit; Larson, Timothy; Noullett, Melanie; Kennedy, Susan; Copes, Ray; Brauer, Michael

    2008-09-01

    Communities impacted by fine-particle air pollution (particles with an aerodynamic diameter less than 2.5 microm; PM(2.5)) from forest fires and residential wood burning require effective, evidence-based exposure-reduction strategies. Public health recommendations during smoke episodes typically include advising community members to remain indoors and the use of air cleaners, yet little information is available on the effectiveness of these measures. Our study attempted to address the following objectives: to measure indoor infiltration factor (F(inf)) of PM(2.5) from forest fires/wood smoke, to determine the effectiveness of high-efficiency particulate air (HEPA) filter air cleaners in reducing indoor PM(2.5), and to analyze the home determinants of F(inf) and air cleaner effectiveness (ACE). We collected indoor/outdoor 1-min PM(2.5) averages and 48-h outdoor PM(2.5) filter samples for 21 winter and 17 summer homes impacted by wood burning and forest fire smoke, respectively, during 2004-2005. A portable HEPA filter air cleaner was operated indoors with the filter removed for one of two sampling days. Particle F(inf) and ACE were calculated for each home using a recursive model. We found mean F(inf)+/-SD was 0.27+/-0.18 and 0.61+/-0.27 in winter (n=19) and summer (n=13), respectively, for days when HEPA filters were not used. Lower F(inf)+/-SD values of 0.10+/-0.08 and 0.19+/-0.20 were found on corresponding days when HEPA filters were in place. Mean+/-SD ACE ([F(inf) without filter-F(inf) with filter]/F(inf) without filter) in winter and summer were 55+/-38% and 65+/-35%, respectively. Number of windows and season predicted F(inf) (P<0.001). No significant predictors of ACE were identified. Our findings show that remaining indoors combined with use of air cleaner can effectively reduce PM(2.5) exposure during forest fires and residential wood burning.

  12. Microbial community analysis in biotrickling filters treating isopropanol air emissions.

    PubMed

    Pérez, M Carmen; Alvarez-Hornos, F Javier; San-Valero, Pau; Marzal, Paula; Gabaldón, Carmen

    2013-01-01

    The evolution of the microbial community was analysed over one year in two biotrickling filters operating under intermittent feeding conditions and treating isopropanol emissions, a pollutant typically found in the flexography sector. Each reactor was packed with one media: plastic cross-flow-structured material or polypropylene rings. The communities were monitored by fluorescence in situ hybridization (FISH) and denaturing gradient gel electrophoresis (DGGE) analysis of the 16S rRNA region. After inoculation with activated sludge, the biotrickling filters were operated using inlet loads (ILs) from 20 to 65 g C m(-3) h(-1) and empty-bed residence times (EBRTs) from 14 to 160 s. Removal efficiencies higher than 80% were obtained with ILs up to 35 g C m(-3) h(-1) working at EBRTs as low as 24 s. There was an increase in the total percentage of the target domains of up to around 80% at the end of the experiment. Specifically, the Gammaproteobacteria domain group, which includes the well-known volatile organic compound (VOC)-degrading species such as Pseudomonas putida, showed a noticeable rise in the two biotrickling filters of 26% and 27%, respectively. DGGE pattern band analysis revealed a stable band of Pseudomonas putida in all the samples monitored, even in the lower diversity communities. In addition, at similar operational conditions, the biotrickling filter with a greater relative abundance of Pseudomonas sp. (19.2% vs. 8%) showed higher removal efficiency (90% vs. 79%). Results indicate the importance of undertaking a further in-depth study of the involved species in the biofiltration process and their specific function.

  13. Thoron ( 220Rn) progeny reduction by an air cleaner of the polarized media filter type

    NASA Astrophysics Data System (ADS)

    Bigu, J.

    1993-02-01

    The effect of an air cleaner on 220Rn progeny atmospheres has been studied in a Radon/Thoron Test Facility (RTTF) of the walk-in type. The air cleaner consists basically of a fan and a special filter material sandwiched between two metal screens, to which an electric field is applied. The filter is of the polarized media type and uses fibreglass as material. The fan and filter system are housed in a metal case. Air is drawn from the back of the case by means of the fan and forced through the "electrical" filter where removal of the 220Rn progeny occurs. Radon-220 progeny "depleted" air is discharged at the top of the device. Tests were conducted in 220Rn/ 220Rn progeny atmospheres when the air cleaner was operating, and when it was turned off. Very pronounced effects were observed during the operation of the device, namely: a dramatic decrease in the 220Rn progeny concentrations and the total aerosol concentration, as well as a large increase in the 220Rn progeny unattached fractions and the plate-out of these radionuclides on the walls of the RTTF. The air cleaner has potential in industrial applications, which should be explored.

  14. Operational test report for 241-AW tank inlet air control stations

    SciTech Connect

    Minteer, D.J., Westinghouse Hanford

    1996-07-03

    This document reports the results of operational testing on tank inlet air control stations in 241-AW tank farm. An air control station was installed on each of the six AW tanks. Operational testing consisted of a simple functional test of each station`s air flow controller, aerosol testing of each station`s HEPA filter, and final ventilation system balancing (i.e., tank airflows and vacuum level) using the air control stations. The test was successful and the units were subsequently placed into operation.

  15. In situ fabrication of depth-type hierarchical CNT/quartz fiber filters for high efficiency filtration of sub-micron aerosols and high water repellency

    NASA Astrophysics Data System (ADS)

    Li, Peng; Zong, Yichen; Zhang, Yingying; Yang, Mengmeng; Zhang, Rufan; Li, Shuiqing; Wei, Fei

    2013-03-01

    We fabricated depth-type hierarchical CNT/quartz fiber (QF) filters through in situ growth of CNTs upon quartz fiber (QF) filters using a floating catalyst chemical vapor deposition (CVD) method. The filter specific area of the CNT/QF filters is more than 12 times higher than that of the pristine QF filters. As a result, the penetration of sub-micron aerosols for CNT/QF filters is reduced by two orders of magnitude, which reaches the standard of high-efficiency particulate air (HEPA) filters. Simultaneously, due to the fluffy brush-like hierarchical structure of CNTs on QFs, the pore size of the hybrid filters only has a small increment. The pressure drop across the CNT/QF filters only increases about 50% with respect to that of the pristine QF filters, leading to an obvious increased quality factor of the CNT/QF filters. Scanning electron microscope images reveal that CNTs are very efficient in capturing sub-micron aerosols. Moreover, the CNT/QF filters show high water repellency, implying their superiority for applications in humid conditions.We fabricated depth-type hierarchical CNT/quartz fiber (QF) filters through in situ growth of CNTs upon quartz fiber (QF) filters using a floating catalyst chemical vapor deposition (CVD) method. The filter specific area of the CNT/QF filters is more than 12 times higher than that of the pristine QF filters. As a result, the penetration of sub-micron aerosols for CNT/QF filters is reduced by two orders of magnitude, which reaches the standard of high-efficiency particulate air (HEPA) filters. Simultaneously, due to the fluffy brush-like hierarchical structure of CNTs on QFs, the pore size of the hybrid filters only has a small increment. The pressure drop across the CNT/QF filters only increases about 50% with respect to that of the pristine QF filters, leading to an obvious increased quality factor of the CNT/QF filters. Scanning electron microscope images reveal that CNTs are very efficient in capturing sub-micron aerosols

  16. Distribution and Rate of Microbial Processes in an Ammonia-Loaded Air Filter Biofilm▿

    PubMed Central

    Juhler, Susanne; Revsbech, Niels Peter; Schramm, Andreas; Herrmann, Martina; Ottosen, Lars D. M.; Nielsen, Lars Peter

    2009-01-01

    The in situ activity and distribution of heterotrophic and nitrifying bacteria and their potential interactions were investigated in a full-scale, two-section, trickling filter designed for biological degradation of volatile organics and NH3 in ventilation air from pig farms. The filter biofilm was investigated by microsensor analysis, fluorescence in situ hybridization, quantitative PCR, and batch incubation activity measurements. In situ aerobic activity showed a significant decrease through the filter, while the distribution of ammonia-oxidizing bacteria (AOB) was highly skewed toward the filter outlet. Nitrite oxidation was not detected during most of the experimental period, and the AOB activity therefore resulted in NO2−, accumulation, with concentrations often exceeding 100 mM at the filter inlet. The restriction of AOB to the outlet section of the filter was explained by both competition with heterotrophic bacteria for O2 and inhibition by the protonated form of NO2−, HNO2. Product inhibition of AOB growth could explain why this type of filter tends to emit air with a rather constant NH3 concentration irrespective of variations in inlet concentration and airflow. PMID:19363071

  17. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    SciTech Connect

    Barnett, J. Matthew; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-02-17

    Since the mid-1980s, Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as the correction factor for self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. This value accounts for activity that cannot be detected by direct counting of alpha and beta particles. Emissions can be degraded or blocked by filter fibers for particles buried in the filter material or by inactive dust particles collected with the radioactive particles. These filters are used for monitoring air emissions from PNNL stacks for radioactive particles. This paper describes an effort to re-evaluate self-absorption effects in particulate radioactive air sample filters (Versapor® 3000, 47 mm diameter) used at PNNL. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Filter ratios were calculated by dividing the initial counts by the post-digestion counts with the expectation that post-digestion counts would be higher because digestion would expose radioactivity embedded in the filter in addition to that on top of the filter. Contrary to expectations, the post digestion readings were almost always lower than initial readings and averaged approximately half the initial readings for both alpha and beta activity. Before and after digestion readings appeared to be related to each other, but with a low coefficient of determination (R^2) value. The ratios had a wide range of values indicating that this method did not provide sufficient precision to quantify self

  18. First report of Legionella pneumophila in car cabin air filters. Are these a potential exposure pathway for professional drivers?

    PubMed

    Alexandropoulou, Ioanna G; Konstantinidis, Theocharis G; Parasidis, Theodoros A; Nikolaidis, Christos; Panopoulou, Maria; Constantinidis, Theodoros C

    2013-12-01

    Recent findings have identified professional drivers as being at an increased risk of Legionnaires' disease. Our hypothesis was that used car cabin air filters represent a reservoir of Legionella bacteria, and thus a potential pathway for contamination. We analysed used cabin air filters from various types of car. The filters were analysed by culture and by molecular methods. Our findings indicated that almost a third of air filters were colonized with Legionella pneumophila. Here, we present the first finding of Legionella spp. in used car cabin air filters. Further investigations are needed in order to confirm this exposure pathway. The presence of Legionella bacteria in used cabin air filters may have been an unknown source of infection until now.

  19. Development of an air cleaning system for dissolving high explosives from nuclear warheads

    SciTech Connect

    Bergman, W.; Wilson, K.; Staggs, K.; Wapman, D.

    1997-08-01

    The Department of Energy (DOE) has a major effort underway in dismantling nuclear weapons. In support of this effort we have been developing a workstation for removing the high explosive (HE) from nuclear warheads using hot sprays of dimethyl sulfoxide (DMSO) solvent to dissolve the HE. An important component of the workstation is the air cleaning system that is used to contain DMSO aerosols and vapor and radioactive aerosols. The air cleaning system consists of a condenser to liquefy the hot DMSO vapor, a demister pad to remove most of the DMSO aerosols, a high efficiency particulate air (HEPA) filter to remove the remaining aerosols, an activated carbon filter to remove the DMSO vapor, and a final HEPA filter to meet the redundancy requirement for HEPA filters in radioactive applications. The demister pad is a 4{double_prime} thick mat of glass and steel fibers and was selected after conducting screening tests on promising candidates. We also conducted screening tests on various activated carbons and found that all had a similar performance. The carbon breakthrough curves were fitted to a modified Wheeler`s equation and gave excellent predictions for the effect of different flow rates. After all of the components were assembled, we ran a series of performance tests on the components and system to determine the particle capture efficiency as a function of size for dioctyl sebacate (DOS) and DMSO aerosols using laser particle counters and filter samples. The pad had an efficiency greater than 990% for 0.1 {mu}m DMSO particles. Test results on the prototype carbon filter showed only 70% efficiency, instead of the 99.9% in small scale laboratory tests. Thus further work will be required to develop the prototype carbon filter. 7 refs., 18 figs., 10 tabs.

  20. Air-mass flux measurement system using Doppler-shifted filtered Rayleigh scattering

    NASA Technical Reports Server (NTRS)

    Shirley, John A.; Winter, Michael

    1993-01-01

    An optical system has been investigated to measure mass flux distributions in the inlet of a high speed air-breathing propulsion system. Rayleigh scattered light from air is proportional to the number density of molecules and hence can be used to ascertain the gas density in a calibrated system. Velocity field measurements are achieved by spectrally filtering the elastically-scattered Doppler-shifted light with an absorbing molecular filter. A novel anamorphic optical collection system is used which allows optical rays from different scattering angles, that have different Doppler shifts, to be recorded separately. This is shown to obviate the need to tune the laser through the absorption to determine velocities, while retaining the ability to make spatially-resolved measurements along a line. By properly selecting the laser tuning and filter parameters, simultaneous density measurements can be made. These properties are discussed in the paper and experiments demonstrating the velocimetry capability are described.

  1. Summary of Martian Dust Filtering Challenges and Current Filter Development

    NASA Technical Reports Server (NTRS)

    O'Hara, William J., IV

    2017-01-01

    Traditional air particulate filtering in manned spaceflight (Apollo, Shuttle, ISS, etc.) has used cleanable or replaceable catch filters such as screens and High-Efficiency Particulate Arrestance (HEPA) filters. However, the human mission to Mars architecture will require a new approach. It is Martian dust that is the particulate of concern but the need also applies to particulates generated by crew. The Mars Exploration Program Analysis Group (MEPAG) high-lighted this concern in its Mars Science, Goals, Objectives, Investigations and Priorities document [7], by saying specifically that one high priority investigation will be to "Test ISRU atmospheric processing systems to measure resilience with respect to dust and other environmental challenge performance parameters that are critical to the design of a full-scale system." By stating this as high priority the MEPAG is acknowledging that developing and adequately verifying this capability is critical to success of a human mission to Mars. This architecture will require filtering capabilities that are highly reliable, will not restrict the flow path with clogging, and require little to no maintenance. This paper will summarize why this is the case, the general requirements for developing the technology, and the status of the progress made in this area.

  2. Removal of ozone on clean, dusty and sooty supply air filters

    NASA Astrophysics Data System (ADS)

    Hyttinen, Marko; Pasanen, Pertti; Kalliokoski, Pentti

    The removal of ozone (O 3) on supply air filters was studied. Especially, the effects of dust load, diesel soot, relative humidity (RH), and exposure time on the removal of O 3 were investigated. Some loss of O 3 was observed in all the filters, except in an unused G3 pre-filter made of polyester. Dust load and quality influenced the reduction of O 3; especially, diesel soot removed O 3 effectively. Increasing the RH resulted in a larger O 3 removal. The removal of O 3 was highest in the beginning of the test, but it declined within 2 h reaching almost a steady state as the exposure continued. However, the sooty filters continued to remove as much as 25-30% of O 3. Up to 11% of O 3 removed participated in the production of formaldehyde. Small amounts of other oxidation products were also detected.

  3. Level-1C Product from AIRS: Principal Component Filtering

    NASA Technical Reports Server (NTRS)

    Manning, Evan M.; Jiang, Yibo; Aumann, Hartmut H.; Elliott, Denis A.; Hannon, Scott

    2012-01-01

    The Atmospheric Infrared Sounder (AIRS), launched on the EOS Aqua spacecraft on May 4, 2002, is a grating spectrometer with 2378 channels in the range 3.7 to 15.4 microns. In a grating spectrometer each individual radiance measurement is largely independent of all others. Most measurements are extremely accurate and have very low noise levels. However, some channels exhibit high noise levels or other anomalous behavior, complicating applications needing radiances throughout a band, such as cross-calibration with other instruments and regression retrieval algorithms. The AIRS Level-1C product is similar to Level-1B but with instrument artifacts removed. This paper focuses on the "cleaning" portion of Level-1C, which identifies bad radiance values within spectra and produces substitute radiances using redundant information from other channels. The substitution is done in two passes, first with a simple combination of values from neighboring channels, then with principal components. After results of the substitution are shown, differences between principal component reconstructed values and observed radiances are used to investigate detailed noise characteristics and spatial misalignment in other channels.

  4. Effects of Temperature, Humidity and Air Flow on Fungal Growth Rate on Loaded Ventilation Filters.

    PubMed

    Tang, W; Kuehn, T H; Simcik, Matt F

    2015-01-01

    This study compares the fungal growth ratio on loaded ventilation filters under various temperature, relative humidity (RH), and air flow conditions in a controlled laboratory setting. A new full-size commercial building ventilation filter was loaded with malt extract nutrients and conidia of Cladosporium sphaerospermum in an ASHRAE Standard 52.2 filter test facility. Small sections cut from this filter were incubated under the following conditions: constant room temperature and a high RH of 97%; sinusoidal temperature (with an amplitude of 10°C, an average of 23°C, and a period of 24 hr) and a mean RH of 97%; room temperature and step changes between 97% and 75% RH, 97% and 43% RH, and 97% and 11% RH every 12 hr. The biomass on the filter sections was measured using both an elution-culture method and by ergosterol assay immediately after loading and every 2 days up to 10 days after loading. Fungal growth was detected earlier using ergosterol content than with the elution-culture method. A student's t-test indicated that Cladosporium sphaerospermum grew better at the constant room temperature condition than at the sinusoidal temperature condition. By part-time exposure to dry environments, the fungal growth was reduced (75% and 43% RH) or even inhibited (11% RH). Additional loaded filters were installed in the wind tunnel at room temperature and an RH greater than 95% under one of two air flow test conditions: continuous air flow or air flow only 9 hr/day with a flow rate of 0.7 m(3)/s (filter media velocity 0.15 m/s). Swab tests and a tease mount method were used to detect fungal growth on the filters at day 0, 5, and 10. Fungal growth was detected for both test conditions, which indicates that when temperature and relative humidity are optimum, controlling the air flow alone cannot prevent fungal growth. In real applications where nutrients are less sufficient than in this laboratory study, fungal growth rate may be reduced under the same operating conditions.

  5. Radiological background levels found on glass fiber filters used for low-level environmental surveillance air sampling

    SciTech Connect

    Althouse, P. E.

    1998-09-16

    Environmental surveillance of low-level radioactive particles in air requires a thorough understanding of low-level techniques and air sample collection media. High-volume air sampling for radioactive particles around Lawrence Livermore National Laboratory (LLNL) employs glass-fiber filters that are analyzed for gross alpha and gross beta activity and for specific isotopes. This study was conducted to determine the activities of radionuclides contained in blank glass-fiber filters. Data from this study provided a partial explanation of differences between current reported concentrations of radionuclides in air and those reported historically when cellulose filters were used in the LLNL monitoring effort.

  6. Bioaerosol DNA Extraction Technique from Air Filters Collected from Marine and Freshwater Locations

    NASA Astrophysics Data System (ADS)

    Beckwith, M.; Crandall, S. G.; Barnes, A.; Paytan, A.

    2015-12-01

    Bioaerosols are composed of microorganisms suspended in air. Among these organisms include bacteria, fungi, virus, and protists. Microbes introduced into the atmosphere can drift, primarily by wind, into natural environments different from their point of origin. Although bioaerosols can impact atmospheric dynamics as well as the ecology and biogeochemistry of terrestrial systems, very little is known about the composition of bioaerosols collected from marine and freshwater environments. The first step to determine composition of airborne microbes is to successfully extract environmental DNA from air filters. We asked 1) can DNA be extracted from quartz (SiO2) air filters? and 2) how can we optimize the DNA yield for downstream metagenomic sequencing? Aerosol filters were collected and archived on a weekly basis from aquatic sites (USA, Bermuda, Israel) over the course of 10 years. We successfully extracted DNA from a subsample of ~ 20 filters. We modified a DNA extraction protocol (Qiagen) by adding a beadbeating step to mechanically shear cell walls in order to optimize our DNA product. We quantified our DNA yield using a spectrophotometer (Nanodrop 1000). Results indicate that DNA can indeed be extracted from quartz filters. The additional beadbeating step helped increase our yield - up to twice as much DNA product was obtained compared to when this step was omitted. Moreover, bioaerosol DNA content does vary across time. For instance, the DNA extracted from filters from Lake Tahoe, USA collected near the end of June decreased from 9.9 ng/μL in 2007 to 3.8 ng/μL in 2008. Further next-generation sequencing analysis of our extracted DNA will be performed to determine the composition of these microbes. We will also model the meteorological and chemical factors that are good predictors for microbial composition for our samples over time and space.

  7. Impregnated filters for the collection of ethanethiol and butanethiol in air

    SciTech Connect

    Knarr, R.D.; Rappaport, S.M.

    1981-11-01

    The use of glass-fiber filters impregnated with mercuric acetate is described for the collection of methanethiol and butanethiol in air. The entrapped thiol is regenerated from the mercuric mercaptide, formed on the filter during sampling, by treatment with acid. Samples are analyzed by gas chromatography with a relative error of +/- 4% and a RSD of less than 2%. The method may be used for the measurement of long-term or short-term exposures in the range of 0.1 to 1 ppm.

  8. Method for contamination control and barrier apparatus with filter for containing waste materials that include dangerous particulate matter

    DOEpatents

    Pinson, P.A.

    1998-02-24

    A container for hazardous waste materials that includes air or other gas carrying dangerous particulate matter has incorporated barrier material, preferably in the form of a flexible sheet, and one or more filters for the dangerous particulate matter sealably attached to such barrier material. The filter is preferably a HEPA type filter and is preferably chemically bonded to the barrier materials. The filter or filters are preferably flexibly bonded to the barrier material marginally and peripherally of the filter or marginally and peripherally of air or other gas outlet openings in the barrier material, which may be a plastic bag. The filter may be provided with a backing panel of barrier material having an opening or openings for the passage of air or other gas into the filter or filters. Such backing panel is bonded marginally and peripherally thereof to the barrier material or to both it and the filter or filters. A coupling or couplings for deflating and inflating the container may be incorporated. Confining a hazardous waste material in such a container, rapidly deflating the container and disposing of the container, constitutes one aspect of the method of the invention. The chemical bonding procedure for producing the container constitutes another aspect of the method of the invention. 3 figs.

  9. Method for contamination control and barrier apparatus with filter for containing waste materials that include dangerous particulate matter

    DOEpatents

    Pinson, Paul A.

    1998-01-01

    A container for hazardous waste materials that includes air or other gas carrying dangerous particulate matter has incorporated in barrier material, preferably in the form of a flexible sheet, one or more filters for the dangerous particulate matter sealably attached to such barrier material. The filter is preferably a HEPA type filter and is preferably chemically bonded to the barrier materials. The filter or filters are preferably flexibly bonded to the barrier material marginally and peripherally of the filter or marginally and peripherally of air or other gas outlet openings in the barrier material, which may be a plastic bag. The filter may be provided with a backing panel of barrier material having an opening or openings for the passage of air or other gas into the filter or filters. Such backing panel is bonded marginally and peripherally thereof to the barrier material or to both it and the filter or filters. A coupling or couplings for deflating and inflating the container may be incorporated. Confining a hazardous waste material in such a container, rapidly deflating the container and disposing of the container, constitutes one aspect of the method of the invention. The chemical bonding procedure for producing the container constitutes another aspect of the method of the invention.

  10. Fabrication and characterization of micro-porous cellulose filters for indoor air quality control.

    PubMed

    Yoon, Younghan; Kim, Sungyoun; Ahn, Kwang Ho; Ko, Kwang Baik; Kim, Kwang-Soo

    2016-01-01

    Micro-porous cellulose filters were fabricated from paper mulberry pulp, which has been used for thousands of years with Korean history. 'Han-ji' is the name of a traditional paper used widely in Korea in construction, textile, craftworks and many household items but before now it has not been used for filtration purpose. Seeking for the utilization of this abundant natural material, this study aims to develop a fabrication process for the traditional paper to be used as a filter for dust filtration, and evaluate the performance by lab-scale experiments. To create pores in the paper, cellulose pulp was pretreated using several methods such as TEMPO oxidation and enzyme hydrolysis, or freeze dried with an alcoholic freezing medium, t-butyl alcohol, instead of water. The filters were characterized and their dust removal performance was tested at a lab scale while also monitoring pressure loss. Chemical oxidation and enzymatic pretreatment were helpful in fabricating a homogeneous filter but would not remove fine-dust particles because of its loose, enlarged pores. The best removal efficiency was observed with filters that were not pretreated but in which water had been exchanged with t-butyl alcohol before freeze-drying. The filter attained a dust removal efficiency higher than 99% over the entire experimental period, with a pressure loss of less than 230 Pa, at a 6.67 (cm3/s)/cm2 air-to-cloth ratio.

  11. Problems in creation of modern air inlet filters of power gas turbine plants in Russia and methods of their solving

    NASA Astrophysics Data System (ADS)

    Mikhaylov, V. E.; Khomenok, L. A.; Sherapov, V. V.

    2016-08-01

    The main problems in creation and operation of modern air inlet paths of gas turbine plants installed as part of combined-cycle plants in Russia are presented. It is noted that design features of air inlet filters shall be formed at the stage of the technical assignment not only considering the requirements of gas turbine plant manufacturer but also climatic conditions, local atmospheric air dustiness, and a number of other factors. The recommendations on completing of filtration system for air inlet filter of power gas turbine plants depending on the facility location are given, specific defects in design and experience in operation of imported air inlet paths are analyzed, and influence of cycle air preparation quality for gas turbine plant on value of operating expenses and cost of repair works is noted. Air treatment equipment of various manufacturers, influence of aerodynamic characteristics on operation of air inlet filters, features of filtration system operation, anti-icing system, weather canopies, and other elements of air inlet paths are considered. It is shown that nonuniformity of air flow velocity fields in clean air chamber has a negative effect on capacity and aerodynamic resistance of air inlet filter. Besides, the necessity in installation of a sufficient number of differential pressure transmitters allowing controlling state of each treatment stage not being limited to one measurement of total differential pressure in the filtration system is noted in the article. According to the results of the analysis trends and methods for modernization of available equipment for air inlet path, the importance of creation and implementation of new technologies for manufacturing of filtering elements on sites of Russia within the limits of import substitution are given, and measures on reliability improvement and energy efficiency for air inlet filter are considered.

  12. Spectral Cloud-Filtering of AIRS Data: Non-Polar Ocean

    NASA Technical Reports Server (NTRS)

    Aumann, Hartmut H.; Gregorich, David; Barron, Diana

    2004-01-01

    The Atmospheric Infrared Sounder (AIRS) is a grating array spectrometer which covers the thermal infrared spectral range between 640 and 1700/cm. In order to retain the maximum radiometric accuracy of the AIRS data, the effects of cloud contamination have to be minimized. We discuss cloud filtering which uses the high spectral resolution of AIRS to identify about 100,000 of 500,000 non-polar ocean spectra per day as relatively "cloud-free". Based on the comparison of surface channels with the NCEP provided global real time sst (rtg.sst), AIRS surface sensitive channels have a cold bias ranging from O.5K during the day to 0.8K during the night. Day and night spatial coherence tests show that the cold bias is due to cloud contamination. During the day the cloud contamination is due to a 2-3% broken cloud cover at the 1-2 km altitude, characteristic of low stratus clouds. The cloud-contamination effects surface sensitive channels only. Cloud contamination can be reduced to 0.2K by combining the spectral filter with a spatial coherence threshold, but the yield drops to 16,000 spectra per day. AIRS was launched in May 2002 on the Earth Observing System (EOS) Aqua satellite. Since September 2002 it has returned 4 million spectra of the globe each day.

  13. Sintered composite medium and filter

    DOEpatents

    Bergman, Werner

    1987-01-01

    A particulate filter medium is formed of a sintered composite of 0.5 micron diameter quartz fibers and 2 micron diameter stainless steel fibers. A preferred composition is about 40 vol. % quartz and about 60 vol. % stainless steel fibers. The media is sintered at about 1100.degree. C. to bond the stainless steel fibers into a cage network which holds the quartz fibers. High filter efficiency and low flow resistance are provided by the smaller quartz fibers. High strength is provided by the stainless steel fibers. The resulting media has a high efficiency and low pressure drop similar to the standard HEPA media, with tensile strength at least four times greater, and a maximum operating temperature of about 550.degree. C. The invention also includes methods to form the composite media and a HEPA filter utilizing the composite media. The filter media can be used to filter particles in both liquids and gases.

  14. Characterization of Airborne Particles Collected from Car Engine Air Filters Using SEM and EDX Techniques.

    PubMed

    Heredia Rivera, Birmania; Gerardo Rodriguez, Martín

    2016-10-01

    Particulate matter accumulated on car engine air-filters (CAFs) was examined in order to investigate the potential use of these devices as efficient samplers for collecting street level air that people are exposed to. The morphology, microstructure, and chemical composition of a variety of particles were studied using scanning electron microscopy (SEM) and energy-dispersive X-ray (EDX). The particulate matter accumulated by the CAFs was studied in two categories; the first was of removed particles by friction, and the second consisted of particles retained on the filters. Larger particles with a diameter of 74-10 µm were observed in the first category. In the second one, the detected particles had a diameter between 16 and 0.7 µm. These particles exhibited different morphologies and composition, indicating mostly a soil origin. The elemental composition revealed the presence of three groups: mineral (clay and asphalt), metallic (mainly Fe), and biological particles (vegetal and animal debris). The palynological analysis showed the presence of pollen grains associated with urban plants. These results suggest that CAFs capture a mixture of atmospheric particles, which can be analyzed in order to monitor urban air. Thus, the continuous availability of large numbers of filters and the retroactivity associated to the car routes suggest that these CAFs are very useful for studying the high traffic zones within a city.

  15. Characterization of Airborne Particles Collected from Car Engine Air Filters Using SEM and EDX Techniques

    PubMed Central

    Heredia Rivera, Birmania; Gerardo Rodriguez, Martín

    2016-01-01

    Particulate matter accumulated on car engine air-filters (CAFs) was examined in order to investigate the potential use of these devices as efficient samplers for collecting street level air that people are exposed to. The morphology, microstructure, and chemical composition of a variety of particles were studied using scanning electron microscopy (SEM) and energy-dispersive X-ray (EDX). The particulate matter accumulated by the CAFs was studied in two categories; the first was of removed particles by friction, and the second consisted of particles retained on the filters. Larger particles with a diameter of 74–10 µm were observed in the first category. In the second one, the detected particles had a diameter between 16 and 0.7 µm. These particles exhibited different morphologies and composition, indicating mostly a soil origin. The elemental composition revealed the presence of three groups: mineral (clay and asphalt), metallic (mainly Fe), and biological particles (vegetal and animal debris). The palynological analysis showed the presence of pollen grains associated with urban plants. These results suggest that CAFs capture a mixture of atmospheric particles, which can be analyzed in order to monitor urban air. Thus, the continuous availability of large numbers of filters and the retroactivity associated to the car routes suggest that these CAFs are very useful for studying the high traffic zones within a city. PMID:27706087

  16. EVALUATION OF AIR CLEANING SYSTEMS FOR FFTF CONTAINMENT MARGINS

    SciTech Connect

    POSTMA, A K.; HILLIARD, R K.

    1980-08-01

    Alternative air cleaning concepts were evaluated for possible application to FFTF containment margins. For evaluation purposes, it was assumed that the air cleaning system must process 3.07 m{sup 3}/s (6500 ACFM) of gas containing sodium compound aerosols (mainly NaOH) at temperatures up to 4070C (7000 F) and pressures up to 0.184 MPa (26.4 psia) and accommodate 5450 kg (12,000 lb) of aerosol material. Three systems designed for 90% efficient removal (a venturi scrubber, a submerged gravel scrubber and a spray scrubber) were compared. The submerged gravel scrubber and the venturi scrubber were rated as prime candidates. Four systems designed for 99% removal efficiency (the two optimum scrubbers chosen for 90% removal efficiency fitted with fibrous elements, a sand and gravel filter and a HEPA filter bank) were compared. The tI~ scrubbers were again rated as prime candidates. Both the sand and gravel filter and the HEPA filter bank were found to be excessively large and costly. Considerable experience supports the use of the optimum scrubber systems and it is concluded that their use is technically feasible for the FFTF containment margins application.

  17. Detecting discontinuities in time series of upper air data: Demonstration of an adaptive filter technique

    SciTech Connect

    Zurbenko, I.; Chen, J.; Rao, S.T.

    1997-11-01

    The issue of global climate change due to increased anthropogenic emissions of greenhouse gases in the atmosphere has gained considerable attention and importance. Climate change studies require the interpretation of weather data collected in numerous locations and/or over the span of several decades. Unfortunately, these data contain biases caused by changes in instruments and data acquisition procedures. It is essential that biases are identified and/or removed before these data can be used confidently in the context of climate change research. The purpose of this paper is to illustrate the use of an adaptive moving average filter and compare it with traditional parametric methods. The advantage of the adaptive filter over traditional parametric methods is that it is less effected by seasonal patterns and trends. The filter has been applied to upper air relative humidity and temperature data. Applied to generated data, the filter has a root mean squared error accuracy of about 600 days when locating changes of 0.1 standard deviations and about 20 days for changes of 0.5 standard deviations. In some circumstances, the accuracy of location estimation can be improved through parametric techniques used in conjunction with the adaptive filter.

  18. Preparation, certification and interlaboratory analysis of workplace air filters spiked with high-fired beryllium oxide.

    PubMed

    Oatts, Thomas J; Hicks, Cheryl E; Adams, Amy R; Brisson, Michael J; Youmans-McDonald, Linda D; Hoover, Mark D; Ashley, Kevin

    2012-02-01

    Occupational sampling and analysis for multiple elements is generally approached using various approved methods from authoritative government sources such as the National Institute for Occupational Safety and Health (NIOSH), the Occupational Safety and Health Administration (OSHA) and the Environmental Protection Agency (EPA), as well as consensus standards bodies such as ASTM International. The constituents of a sample can exist as unidentified compounds requiring sample preparation to be chosen appropriately, as in the case of beryllium in the form of beryllium oxide (BeO). An interlaboratory study was performed to collect analytical data from volunteer laboratories to examine the effectiveness of methods currently in use for preparation and analysis of samples containing calcined BeO powder. NIST SRM(®) 1877 high-fired BeO powder (1100 to 1200 °C calcining temperature; count median primary particle diameter 0.12 μm) was used to spike air filter media as a representative form of beryllium particulate matter present in workplace sampling that is known to be resistant to dissolution. The BeO powder standard reference material was gravimetrically prepared in a suspension and deposited onto 37 mm mixed cellulose ester air filters at five different levels between 0.5 μg and 25 μg of Be (as BeO). Sample sets consisting of five BeO-spiked filters (in duplicate) and two blank filters, for a total of twelve unique air filter samples per set, were submitted as blind samples to each of 27 participating laboratories. Participants were instructed to follow their current process for sample preparation and utilize their normal analytical methods for processing samples containing substances of this nature. Laboratories using more than one sample preparation and analysis method were provided with more than one sample set. Results from 34 data sets ultimately received from the 27 volunteer laboratories were subjected to applicable statistical analyses. The observed

  19. Cleanable Air Filter Transferring Moisture and Effectively Capturing PM2.5.

    PubMed

    Zhao, Xinglei; Li, Yuyao; Hua, Ting; Jiang, Pan; Yin, Xia; Yu, Jianyong; Ding, Bin

    2017-03-01

    The lethal danger of particulate matter (PM) pollution on health leads to the development of challenging individual protection materials that should ideally exhibit a high PM2.5 purification efficiency, low air resistance, an important moisture-vapor transmission rate (MVTR), and an easy-to-clean property. Herein, a cleanable air filter able to rapidly transfer moisture and efficiently capture PM2.5 is designed by electrospinning superhydrophilic polyacrylonitrile/silicon-dioxide fibers as the adsorption-desorption vector for moisture-vapor, and hydrophobic polyvinylidene fluoride fibers as the repellent components to avoid the formation of capillary water under high humidity. The desorption rate of water molecules increases from 10 to 18 mg min(-1) , while the diameters of polyacrylonitrile fibers reduce from 1.02 to 0.14 µm. Significantly, by introducing the hydroxyl on the surface of polyacrylonitrile nanofibers, rapid adsorption-desorption of the water molecules is observed. Moreover, by constructing a hydrophobic to super-hydrophilic gradient structure, the MVTR increases from 10 346 to 14 066 g m(-2) d(-1) . Interestingly, the prepared fibrous membranes is easy to clean. More importantly, benefiting from enhanced slip effect, the resultant fibrous membranes presented a low air resistance of 86 Pa. A field test in Shanghai shows that the air filter maintains stable PM2.5 purification efficiency of 99.99% at high MVTR during haze event.

  20. Revisiting Atmospheric Lead in NYC - Comparison of Archived Air Filters to Urban Park Sediments and Soils

    NASA Astrophysics Data System (ADS)

    Chillrud, S. N.; Ross, J. M.; Yan, B.; Bopp, R.

    2015-12-01

    Urban lake sediments have the potential to be used for reconstructing history of aerosols, providing data before the start of urban air quality monitoring. In a previous study, the similarity between radionuclide and excess Pb inventories (57 g/m^2) in Central Park Lake (CPL) sediments and those same parameters in Central Park soils (CPS) was interpreted to indicate that urban lake sediment cores from CPL represent deposition of atmospheric aerosols over the history of the park, which was constructed in the 1860s. Furthermore, metal ratios and metal chronologies indicated that incineration was the major source of Pb to the NYC atmosphere over the 20th century. In this report, we compare the lake chronologies for metals to a set of archived air filters collected by the Department of Energy's Environmental Measurement Lab (EML). These weekly filters of total suspended particulates (TSP) were collected by a high volume sampler located in lower Manhattan for radionuclides as part of the program focused on documenting radioactive fallout from nuclear weapons testing. Metal concentrations measured in subsamples of the EML filters collected between the 1970s to 1990s showed Pb decreasing more slowly than the records of Pb added to gasoline. Metal ratios in the filters were similar to the ratios measured in CPL sediments; the Pb to Sn ratios were roughly 20:1 and the Pb to Zn ratios were in close to 1. The similarity of the ratios provides additional solid support that the CP Lake sediment cores reflect atmospheric inputs. The enrichment of Pb in the large aerosol particle fraction (TSP), relative to fine PM2.5 fraction, demonstrates that the resuspended NYC soils and their historical contaminant burden, are the primary, current source of Pb to NYC air.

  1. Can the use of deactivated glass fibre filters eliminate sorption artefacts associated with active air sampling of perfluorooctanoic acid?

    PubMed

    Johansson, Jana H; Berger, Urs; Cousins, Ian T

    2017-05-01

    Experimental work was undertaken to test whether gaseous perfluorooctanoic acid (PFOA) sorbs to glass fibre filters (GFFs) during air sampling, causing an incorrect measure of the gas-particle equilibrium distribution. Furthermore, tests were performed to investigate whether deactivation by siliconisation prevents sorption of gaseous PFOA to filter materials. An apparatus was constructed to closely simulate a high-volume air sampler, although with additional features allowing introduction of gaseous test compounds into an air stream stripped from particles. The set-up enabled investigation of the sorption of gaseous test compounds to filter media, eliminating any contribution from particles. Experiments were performed under ambient outdoor air conditions at environmentally relevant analyte concentrations. The results demonstrate that gaseous PFOA sorbs to GFFs, but that breakthrough of gaseous PFOA on the GFFs occurs at trace-level loadings. This indicates that during high volume air sampling, filters do not quantitatively capture all the PFOA in the sampled air. Experiments with siliconised GFFs showed that this filter pre-treatment reduced the sorption of gaseous PFOA, but that sorption still occurred at environmentally relevant air concentrations. We conclude that deactivation of GFFs does not allow for the separation of gaseous and particle bound perfluorinated carboxylic acids (PFCAs) during active air sampling. Consequently, the well-recognised theory that PFCAs do not prevail as gaseous species in the atmosphere may be based on biased measurements. Caution should be taken to ensure that this artefact will not bias the conclusions of future field studies.

  2. Physico-chemical Modification of the Fibrous Filter Nozzles for Purification Processes of Water and Air

    NASA Astrophysics Data System (ADS)

    Bordunov, S. V.; Galtseva, O. V.; Natalinova, N. M.; Rogachev, A. A.; Zhang, Ruizhi

    2017-01-01

    A set of experiments to study physical and chemical modification of the surface of fibers is conducted to expand the area of their application for purification of water, gas and air (including that in conditions of space). The possibility of modification of filter nozzles in the process of fiber formation by particles of coal of BAU type, copper sulfide and silver chloride is experimentally shown. The fraction of the copper sulfide powder less than 50 microns in size was crushed in a spherical mill; it was deposited on fiber at air temperature of 50° C and powder consumption of 0.5 g/l of air. The resulting material contained 6–18 CuS particles per 1 cm of the fiber length. An effective bactericidal fibrous material can be produced using rather cheap material – CuS and relatively cheap natural compounds of sulphides and oxides of heavy metals.

  3. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    PubMed

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration.

  4. Nonuniform air flow in inlets: the effect on filter deposits in the fiber sampling cassette.

    PubMed

    Baron, P A; Chen, C C; Hemenway, D R; O'Shaughnessy, P

    1994-08-01

    Smoke stream studies were combined with a new technique for visualizing a filter deposit from samples used to monitor asbestos or other fibers. Results clearly show the effect of secondary flow vortices within the sampler under anisoaxial sampling conditions. The vortices observed at low wind velocities occur when the inlet axis is situated at angles between 45 degrees and 180 degrees to the motion of the surrounding air. It is demonstrated that the vortices can create a complex nonuniform pattern in the filter deposit, especially when combined with particle settling or electrostatic interactions between the particles and the sampler. Inertial effects also may play a role in the deposit nonuniformity, as well as causing deposition on the cowl surfaces. Changes in the sampler, such as its placement, may reduce these biases. The effects noted are not likely to occur in all sampling situations, but may explain some reports of high variability on asbestos fiber filter samples. The flow patterns observed in this study are applicable to straight, thin-walled inlets. Although only compact particles were used, the air flow patterns and forces involved will have similar effects on fibers of the same aerodynamic diameter.

  5. Antimicrobial durability of air filters coated with airborne Sophora flavescens nanoparticles.

    PubMed

    Chong, Eui-Seok; Hwang, Gi Byoung; Nho, Chu Won; Kwon, Bo Mi; Lee, Jung Eun; Seo, Sungchul; Bae, Gwi-Nam; Jung, Jae Hee

    2013-02-01

    Airborne biological particles containing viruses, bacteria, and/or fungi can be toxic and cause infections and allergy symptoms. Recently, natural materials such as tea tree oil and Sophora flavescens have shown promising antimicrobial activity when applied as air filter media. Although many of these studies demonstrated excellent antimicrobial efficacy, only a few of them considered external environmental effects such as the surrounding humidity, temperature, and natural degradation of chemicals, all of which can affect the antimicrobial performance of these natural materials. In this study, we investigated the antimicrobial durability of air filters containing airborne nanoparticles from S. flavescens for 5 months. Antimicrobial tests and quantitative chemical analyses were performed every 30 days. Morphological changes in the nanoparticles were also evaluated by scanning electron microscopy. The major antimicrobial compounds remained stable and active for ~90 days at room temperature. After about 90 days, the quantities of major antimicrobial compounds decreased noticeably with a consequent decrease in antimicrobial activity. These results are promising for the implementation of new technologies using natural antimicrobial products and provide useful information regarding the average life expectancy of antimicrobial filters using nanoparticles of S. flavescens.

  6. [Importance of air purifiers in the prevention of respiratory allergy].

    PubMed

    Sabbah, A

    2000-06-01

    Prevention of respiratory allergy and thus diminution of its prevalence consists of the application not only of preventative measures on the allergens themselves, but also on atmospheric pollutants such as NO, CO and diesel particles. These modify the allergens and increase synthesis of allergen-specific IgE. Use of air purifiers, on condition that they have HEPA or ULPA filters may contribute to reduction of allergenicity linked to pollutants and are one of the not-negligible means of protection from respiratory allergy and asthma in particular.

  7. Effects of MERV 16 filters and routine work practices on enclosed cabs for reducing respirable dust and DPM exposures in an underground limestone mine

    PubMed Central

    Noll, J.D.; Cecala, A.B.; J.A.Organiscak; Rider, J.P.

    2015-01-01

    An effective technique to minimize miners’ respirable dust and diesel exposure on mobile mining equipment is to place mine operators in enclosed cabs with designed filtration and pressurization systems. Many factors affect the performance of these enclosed cab systems, and one of the most significant factors is the effectiveness of the filtration system. High-efficiency particulate air (HEPA)-type filters are typically used because they are highly efficient at capturing all types and sizes of particles, including those in the submicron range such as diesel particulate matter (DPM). However, in laboratory tests, minimum efficiency reporting value (MERV) 16 filters have proven to be highly efficient for capturing DPM and respirable dust. Also, MERV 16 filters can be less restrictive to cab airflow and less expensive than HEPA filters. To verify their effectiveness in the field, MERV 16 filters were used in the enclosed cab filtration system on a face drill and roof bolting mining machine and tested at an underground limestone mine. Test results showed that DPM and respirable dust concentrations were reduced by more than 90% when the cabs were properly sealed. However, when the cab door was opened periodically throughout the shift, the reduction efficiency of the MERV 16 filters was reduced to 80% on average. PMID:26236044

  8. Simultaneous Filtered and Unfiltered Light Scattering Measurements in Laser Generated Air Sparks

    NASA Astrophysics Data System (ADS)

    Limbach, Christopher; Miles, Richard

    2013-09-01

    Elastic laser light scattering may be used to measure the thermofluidic properties of gases and plasmas, including but not limited to density, temperature and velocity. Most of this information is contained within the spectra of the scattered radiation. This may be measured directly through dispersion or indirectly, by passing the light through an atomic or molecular vapor filter with known absorption features. In this work, filtered and unfiltered laser light scattering is used to diagnose air sparks generated by a 1064 nm Q-switched laser. The probe laser consists of a second Q-switched Nd:YAG laser frequency doubled to 532 nm. Simultaneous unfiltered and filtered images of the scattering are captured by a Princeton Instruments ICCD camera by using a 50 mm diameter concave re-imaging mirror. The filter consists of a well-characterized molecular Iodine cell. In the shock wave formed by the laser spark, spatially resolved measurements of density, temperature and radial velocity are extracted and compared with theory and models. Measurements in the spark core probe the ion feature of the electron Thomson scattering, from which ne and T can be extracted with the assumption Te =Ti . Partial funding was provided by General Electric Global Research Center: Niskayuna, New York. The first author is also supported by a National Defense Science and Engineering Graduate Fellowship.

  9. Prototype air cleaning system for a firing range

    SciTech Connect

    Glissmeyer, J.A.; Mishima, J.; Bamberger, J.A.

    1985-01-01

    This report recommends air cleaning system components for the US Army Ballistics Research Laboratory's new large-caliber firing range, which is used for testing depleted uranium (DU) penetrators. The new air cleaning system has lower operating costs during the life of the system compared to that anticipated for the existing air cleaning system. The existing system consists of three banks of filters in series; the first two banks are prefilters and the last are high-efficiency particulate air (HEPA) filters. The principal disadvantage of the existing filters is that they are not cleanable and reusable. Pacific Northwest Laboratory focused the search for alternate air cleaning equipment on devices that do not employ liquids as part of the particle collection mechanism. Collected dry particles were assumed preferable to a liquid waste stream. The dry particle collection devices identified included electrostatic precipitators; inertial separators using turning vanes or cyclones; and several devices employing a filter medium such as baghouses, cartridge houses, cleanable filters, and noncleanable filters similar to those in the existing system. The economics of practical air cleaning systems employing the dry particle collection devices were evaluated in 294 different combinations. 7 references, 21 figures, 78 tables.

  10. Germ-line mutations, DNA damage, and global hypermethylation in mice exposed to particulate air pollution in an urban/industrial location

    PubMed Central

    Yauk, Carole; Polyzos, Aris; Rowan-Carroll, Andrea; Somers, Christopher M.; Godschalk, Roger W.; Van Schooten, Frederik J.; Berndt, M. Lynn; Pogribny, Igor P.; Koturbash, Igor; Williams, Andrew; Douglas, George R.; Kovalchuk, Olga

    2008-01-01

    Particulate air pollution is widespread, yet we have little understanding of the long-term health implications associated with exposure. We investigated DNA damage, mutation, and methylation in gametes of male mice exposed to particulate air pollution in an industrial/urban environment. C57BL/CBA mice were exposed in situ to ambient air near two integrated steel mills and a major highway, alongside control mice breathing high-efficiency air particulate (HEPA) filtered ambient air. PCR analysis of an expanded simple tandem repeat (ESTR) locus revealed a 1.6-fold increase in sperm mutation frequency in mice exposed to ambient air for 10 wks, followed by a 6-wk break, compared with HEPA-filtered air, indicating that mutations were induced in spermatogonial stem cells. DNA collected after 3 or 10 wks of exposure did not exhibit increased mutation frequency. Bulky DNA adducts were below the detection threshold in testes samples, suggesting that DNA reactive chemicals do not reach the germ line and cause ESTR mutation. In contrast, DNA strand breaks were elevated at 3 and 10 wks, possibly resulting from oxidative stress arising from exposure to particles and associated airborne pollutants. Sperm DNA was hypermethylated in mice breathing ambient relative to HEPA-filtered air and this change persisted following removal from the environmental exposure. Increased germ-line DNA mutation frequencies may cause population-level changes in genetic composition and disease. Changes in methylation can have widespread repercussions for chromatin structure, gene expression and genome stability. Potential health effects warrant extensive further investigation. PMID:18195365

  11. Removing hydrogen sulfide from wastewater treatment facilities` air process streams with a biotrickling filter

    SciTech Connect

    Morton, R.L.; Caballero, R.C.

    1997-12-31

    Control of hydrogen sulfide (H{sub 2}S) and odor emissions has been a major consideration for many wastewater treatment plants. Many different methods have been and are currently being used for H{sub 2}S and odor control. Most of the current methods involve absorption of H{sub 2}S and odors into a liquid solution or adsorption onto a solid matrix. These methods are either expensive or if not operated correctly can be inefficient. The Los Angeles County Sanitation Districts have developed a biological method to remove odors and H{sub 2}S from different off-gas streams at its main wastewater treatment plant, the Joint Water Pollution Control Plant (JWPCP). This treatment method, which is known as a biotrickling filter, uses a packed contactor device in which the air to be treated is blown through the packing. The H{sub 2}S and odor is removed by a scrubbing solution containing bacteria that is trickled down from the top of the contactor. Different types of column packing media were tested, with a rock-based media being the most effective. The rock media allowed the biotrickling filter to get over 98 percent removal of inlet H{sub 2}S, as long as H{sub 2}S loadings did not exceed 39 g-H{sub 2}S/m{sup 3}-hr (1.1 g-H{sub 2}S/ft{sup 3}-hr). Odor panel analyses indicated that inlet odors were reduced by 99 percent by the biotrickling filter. Due to the success of the research work, a full scale biotrickling filter is being put into operation at the JWPCP. The unit will replace existing caustic scrubbers and will be much less expensive to operate. Current costs to operate a caustic scrubber at the JWPCP is about $1,150 per million m{sup 3} ($33.00 per million ft3) of air treated. The biotrickling filter operational costs would be about one-fifth or $240 per million m{sup 3} ($7.00 per million ft{sup 3}) of air treated.

  12. International Space Station Bacteria Filter Element Post-Flight Testing and Service Life Prediction

    NASA Technical Reports Server (NTRS)

    Perry, J. L.; von Jouanne, R. G.; Turner, E. H.

    2003-01-01

    The International Space Station uses high efficiency particulate air (HEPA) filters to remove particulate matter from the cabin atmosphere. Known as Bacteria Filter Elements (BFEs), there are 13 elements deployed on board the ISS's U.S. Segment. The pre-flight service life prediction of 1 year for the BFEs is based upon performance engineering analysis of data collected during developmental testing that used a synthetic dust challenge. While this challenge is considered reasonable and conservative from a design perspective, an understanding of the actual filter loading is required to best manage the critical ISS Program resources. Thus testing was conducted on BFEs returned from the ISS to refine the service life prediction. Results from this testing and implications to ISS resource management are discussed. Recommendations for realizing significant savings to the ISS Program are presented.

  13. Efficiency of an air filter at the drainage site in a closed circuit with a centrifugal blood pump: an in vitro study.

    PubMed

    Mitsumaru, A; Yozu, R; Matayoshi, T; Morita, M; Shin, H; Tsutsumi, K; Iino, Y; Kawada, S

    2001-01-01

    In a closed circuit with a centrifugal blood pump, one of the serious obstacles to clinical application is sucking of air bubbles into the drainage circuit. The goal of this study was to investigate the efficiency of an air filter at the drainage site. We used whole bovine blood and the experimental circuit consisted of a drainage circuit, two air filters, a centrifugal blood pump, a membrane oxygenator, a return circuit, and a reservoir. Air was injected into the drainage circuit with a roller pump, and the number and size of air bubbles were measured. The air filter at the drainage site could remove the air bubbles (>40 microm) by itself, but adding a vacuum removed more bubbles (>40 microm) than without vacuum. Our results suggest that an air filter at the drainage site could effectively remove air bubbles, and that adding the filter in a closed circuit with a centrifugal blood pump would be safer.

  14. A Baseline Air Quality Assessment Onboard a Victoria Class Submarine: HMCS Windsor

    DTIC Science & Technology

    2006-05-01

    filtering capacity of any sort whether charcoal or HEPA would significantly reduce the presence of volatile compounds and particulates, and as such...is believed that the plenum space in this class has a limited filtering lining, but with the addition of an activated charcoal filter or a HEPA...conduct of engineering feasibility studies to investigate the potential installation of filtering units to decrease particulate and volatile organic

  15. Detection and removal of impurities in nitric oxide generated from air by pulsed electrical discharge.

    PubMed

    Yu, Binglan; Blaesi, Aron H; Casey, Noel; Raykhtsaum, Grigory; Zazzeron, Luca; Jones, Rosemary; Morrese, Alexander; Dobrynin, Danil; Malhotra, Rajeev; Bloch, Donald B; Goldstein, Lee E; Zapol, Warren M

    2016-11-30

    Inhalation of nitric oxide (NO) produces selective pulmonary vasodilation without dilating the systemic circulation. However, the current NO/N2 cylinder delivery system is cumbersome and expensive. We developed a lightweight, portable, and economical device to generate NO from air by pulsed electrical discharge. The objective of this study was to investigate and optimize the purity and safety of NO generated by this device. By using low temperature streamer discharges in the plasma generator, we produced therapeutic levels of NO with very low levels of nitrogen dioxide (NO2) and ozone. Despite the low temperature, spark generation eroded the surface of the electrodes, contaminating the gas stream with metal particles. During prolonged NO generation there was gradual loss of the iridium high-voltage tip (-90 μg/day) and the platinum-nickel ground electrode (-55 μg/day). Metal particles released from the electrodes were trapped by a high-efficiency particulate air (HEPA) filter. Quadrupole mass spectroscopy measurements of effluent gas during plasma NO generation showed that a single HEPA filter removed all of the metal particles. Mice were exposed to breathing 50 parts per million of electrically generated NO in air for 28 days with only a scavenger and no HEPA filter; the mice did not develop pulmonary inflammation or structural changes and iridium and platinum particles were not detected in the lungs of these mice. In conclusion, an electric plasma generator produced therapeutic levels of NO from air; scavenging and filtration effectively eliminated metallic impurities from the effluent gas.

  16. Use of dust fall filters as passive samplers for metal concentrations in air for communities near contaminated mine tailings.

    PubMed

    Beamer, P I; Sugeng, A J; Kelly, M D; Lothrop, N; Klimecki, W; Wilkinson, S T; Loh, M

    2014-05-01

    Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p < 0.05), whose primary source in indoor air is resuspended soil from outdoors. In the second rural community, our estimated metal concentrations in air were comparable to active air sampling measurements taken previously. This passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites.

  17. Air quality benefits of universal particle filter and NOx controls on diesel trucks

    NASA Astrophysics Data System (ADS)

    Tao, L.; Mcdonald, B. C.; Harley, R.

    2015-12-01

    Heavy-duty diesel trucks are a major source of black carbon/particulate matter and nitrogen oxide emissions on urban and regional scales. These emissions are relevant to both air quality and climate change. Since 2010 in the US, new engines are required to be equipped with emission control systems that greatly reduce both PM and NOx emissions, by ~98% relative to 1988 levels. To reduce emissions from the legacy fleet of older trucks that still remain on the road, regulations have been adopted in Califonia to accelerate the replacement of older trucks and thereby reduce associated emissions of PM and NOx. Use of diesel particle filters will be widespread by 2016, and universal use of catalytic converters for NOx control is required by 2023. We assess the air quality consequences of this clean-up effort in Southern California, using the Community Multiscale Air Quality model (CMAQ), and comparing three scenarios: historical (2005), present day (2016), and future year (2023). Emissions from the motor vehicle sector are mapped at high spatial resolution based on traffic count and fuel sales data. NOx emissions from diesel engines in 2023 are expected to decrease by ~80% compared to 2005, while the fraction of NOx emitted as NO2 is expected to increase from 5 to 18%. Air quality model simulations will be analyzed to quantify changes in NO2, black carbon, particulate matter, and ozone, both basin-wide and near hot spots such as ports and major highways.

  18. A Randomized Cross-over Air Filtration Intervention Trial for Reducing Cardiovascular Health Risks in Residents of Public Housing near a Highway

    PubMed Central

    Padró-Martínez, Luz T.; Owusu, Emmanuel; Reisner, Ellen; Zamore, Wig; Simon, Matthew C.; Mwamburi, Mkaya; Brown, Carrie A.; Chung, Mei; Brugge, Doug; Durant, John L.

    2015-01-01

    Exposure to traffic-generated ultrafine particles (UFP; particles <100 nm) is likely a risk factor for cardiovascular disease. We conducted a trial of high-efficiency particulate arrestance (HEPA) filtration in public housing near a highway. Twenty residents in 19 apartments living <200 m from the highway participated in a randomized, double-blind crossover trial. A HEPA filter unit and a particle counter (measuring particle number concentration (PNC), a proxy for UFP) were installed in living rooms. Participants were exposed to filtered air for 21 days and unfiltered air for 21 days. Blood samples were collected and blood pressure measured at days 0, 21 and 42 after a 12-hour fasting period. Plasma was analyzed for high sensitivity C-reactive protein (hsCRP), interleukin-6 (IL-6), tumor necrosis factor alpha-receptor II (TNF-RII) and fibrinogen. PNC reductions ranging from 21% to 68% were recorded in 15 of the apartments. We observed no significant differences in blood pressure or three of the four biomarkers (hsCRP, fibrinogen, and TNF-RII) measured in participants after 21-day exposure to HEPA-filtered air compared to measurements after 21-day exposure to sham-filtered air. In contrast, IL-6 concentrations were significantly higher following HEPA filtration (0.668 pg/mL; CI = 0.465–0.959) compared to sham filtration. Likewise, PNC adjusted for time activity were associated with increasing IL-6 in 14- and 21-day moving averages, and PNC was associated with decreasing blood pressure in Lags 0, 1 and 2, and in a 3-day moving average. These negative associations were unexpected and could be due to a combination of factors including exposure misclassification, unsuccessful randomization (i.e., IL-6 and use of anti-inflammatory medicines), or uncontrolled confounding. Studies with greater reduction in UFP levels and larger sample sizes are needed. There also needs to be more complete assessment of resident time activity and of outdoor vs. indoor source contributions

  19. A Randomized Cross-over Air Filtration Intervention Trial for Reducing Cardiovascular Health Risks in Residents of Public Housing near a Highway.

    PubMed

    Padró-Martínez, Luz T; Owusu, Emmanuel; Reisner, Ellen; Zamore, Wig; Simon, Matthew C; Mwamburi, Mkaya; Brown, Carrie A; Chung, Mei; Brugge, Doug; Durant, John L

    2015-07-10

    Exposure to traffic-generated ultrafine particles (UFP; particles <100 nm) is likely a risk factor for cardiovascular disease. We conducted a trial of high-efficiency particulate arrestance (HEPA) filtration in public housing near a highway. Twenty residents in 19 apartments living <200 m from the highway participated in a randomized, double-blind crossover trial. A HEPA filter unit and a particle counter (measuring particle number concentration (PNC), a proxy for UFP) were installed in living rooms. Participants were exposed to filtered air for 21 days and unfiltered air for 21 days. Blood samples were collected and blood pressure measured at days 0, 21 and 42 after a 12-hour fasting period. Plasma was analyzed for high sensitivity C-reactive protein (hsCRP), interleukin-6 (IL-6), tumor necrosis factor alpha-receptor II (TNF-RII) and fibrinogen. PNC reductions ranging from 21% to 68% were recorded in 15 of the apartments. We observed no significant differences in blood pressure or three of the four biomarkers (hsCRP, fibrinogen, and TNF-RII) measured in participants after 21-day exposure to HEPA-filtered air compared to measurements after 21-day exposure to sham-filtered air. In contrast, IL-6 concentrations were significantly higher following HEPA filtration (0.668 pg/mL; CI = 0.465-0.959) compared to sham filtration. Likewise, PNC adjusted for time activity were associated with increasing IL-6 in 14- and 21-day moving averages, and PNC was associated with decreasing blood pressure in Lags 0, 1 and 2, and in a 3-day moving average. These negative associations were unexpected and could be due to a combination of factors including exposure misclassification, unsuccessful randomization (i.e., IL-6 and use of anti-inflammatory medicines), or uncontrolled confounding. Studies with greater reduction in UFP levels and larger sample sizes are needed. There also needs to be more complete assessment of resident time activity and of outdoor vs. indoor source contributions

  20. Effectiveness of photocatalytic filter for removing volatile organic compounds in the heating, ventilation, and air conditioning system.

    PubMed

    Yu, Kuo-Pin; Lee, Grace Whei-May; Huang, Wei-Ming; Wu, Chih-Cheng; Lou, Chia-ling; Yang, Shinhao

    2006-05-01

    Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photocatalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr(-1), and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and formaldehyde found in this study ranged from 0.381 to 1.01 hr(-1) under different total air change rates, from 0.34 to 0.433 hr(-1) under different RH, and from 0.381 to 0.433 hr(-1) for different photocatalytic filters.

  1. PLUTONIUM-URANIUM EXTRACTION (PUREX) FACILITY ALARACT DEMONSTRATION FOR FILTER HOUSING

    SciTech Connect

    LEBARON GJ

    2008-11-25

    This document presents an As Low As Reasonably Achievable Control Technology (ALARACT) demonstration for evaluating corrosion on the I-beam supporting filter housing No.9 for the 291-A-l emission unit of the Plutonium-Uranium Extraction (PUREX) Facility, located in the 200 East Area of the Hanford Site. The PUREX facility is currently in surveillance and maintenance mode. During a State of Washington, Department of Health (WDOH) 291-A-l emission unit inspection, a small amount of corrosion was observed at the base of a high-efficiency particulate air (HEPA) filter housing. A series of internal and external inspections identified the source of the corrosion material as oxidation of a small section of one of the carbon steel I-beams that provides support to the stainless steel filter housing. The inspections confirmed the corrosion is isolated to one I-beam support location and does not represent any compromise of the structural support or filter housing integrity. Further testing and inspections of the support beam corrosion and its cause were conducted but did not determine the cause. No definitive evidence was found to support any degradation of the housing. Although no degradation of the housing was found, a conservative approach will be implemented. The following actions will be taken: (1) The current operating filter housing No.9 will be removed from service. (2) The only remaining available filter housings (No.1, No.2, and No.3) will be placed in service. These filter housings have new HEPA filters fitted with stainless steel frames and faceguards which were installed in the spring of 2007. (3) Filter housings No.5 and No.10 will be put on standby as backups. To document the assessment of the unit, a draft ALARACT filter housing demonstration for the PUREX filter housing was prepared, and informally provided to WDOH on August 7, 2008. A follow up WDOH response to the draft ALARACT filter housing demonstration for the PUREX filter housing questioned whether

  2. Workplace Exposure to Titanium Dioxide Nanopowder Released from a Bag Filter System

    PubMed Central

    Ji, Jun Ho; Kim, Jong Bum; Lee, Gwangjae; Noh, Jung-Hun; Yook, Se-Jin; Cho, So-Hye; Bae, Gwi-Nam

    2015-01-01

    Many researchers who use laboratory-scale synthesis systems to manufacture nanomaterials could be easily exposed to airborne nanomaterials during the research and development stage. This study used various real-time aerosol detectors to investigate the presence of nanoaerosols in a laboratory used to manufacture titanium dioxide (TiO2). The TiO2 nanopowders were produced via flame synthesis and collected by a bag filter system for subsequent harvesting. Highly concentrated nanopowders were released from the outlet of the bag filter system into the laboratory. The fractional particle collection efficiency of the bag filter system was only 20% at particle diameter of 100 nm, which is much lower than the performance of a high-efficiency particulate air (HEPA) filter. Furthermore, the laboratory hood system was inadequate to fully exhaust the air discharged from the bag filter system. Unbalanced air flow rates between bag filter and laboratory hood systems could result in high exposure to nanopowder in laboratory settings. Finally, we simulated behavior of nanopowders released in the laboratory using computational fluid dynamics (CFD). PMID:26125024

  3. Workplace Exposure to Titanium Dioxide Nanopowder Released from a Bag Filter System.

    PubMed

    Ji, Jun Ho; Kim, Jong Bum; Lee, Gwangjae; Noh, Jung-Hun; Yook, Se-Jin; Cho, So-Hye; Bae, Gwi-Nam

    2015-01-01

    Many researchers who use laboratory-scale synthesis systems to manufacture nanomaterials could be easily exposed to airborne nanomaterials during the research and development stage. This study used various real-time aerosol detectors to investigate the presence of nanoaerosols in a laboratory used to manufacture titanium dioxide (TiO2). The TiO2 nanopowders were produced via flame synthesis and collected by a bag filter system for subsequent harvesting. Highly concentrated nanopowders were released from the outlet of the bag filter system into the laboratory. The fractional particle collection efficiency of the bag filter system was only 20% at particle diameter of 100 nm, which is much lower than the performance of a high-efficiency particulate air (HEPA) filter. Furthermore, the laboratory hood system was inadequate to fully exhaust the air discharged from the bag filter system. Unbalanced air flow rates between bag filter and laboratory hood systems could result in high exposure to nanopowder in laboratory settings. Finally, we simulated behavior of nanopowders released in the laboratory using computational fluid dynamics (CFD).

  4. An introduction to the design, commissioning and operation of nuclear air cleaning systems for Qinshan Nuclear Power Plant

    SciTech Connect

    Xinliang Chen; Jiangang Qu; Minqi Shi

    1995-02-01

    This paper introduces the design evolution, system schemes and design and construction of main nuclear air cleaning components such as HEPA filter, charcoal adsorber and concrete housing etc. for Qinshan 300MW PWR Nuclear Power Plant (QNPP), the first indigenously designed and constructed nuclear power plant in China. The field test results and in-service test results, since the air cleaning systems were put into operation 18 months ago, are presented and evaluated. These results demonstrate that the design and construction of the air cleaning systems and equipment manufacturing for QNPP are successful and the American codes and standards invoked in design, construction and testing of nuclear air cleaning systems for QNPP are applicable in China. The paper explains that the leakage rate of concrete air cleaning housings can also be assured if sealing measures are taken properly and embedded parts are designed carefully in the penetration areas of the housing and that the uniformity of the airflow distribution upstream the HEPA filters can be achieved generally no matter how inlet and outlet ducts of air cleaning unit are arranged.

  5. Use of Free-standing Filters in an Asthma Intervention Study

    PubMed Central

    Batterman, Stuart; Du, Liuliu; Parker, Edith; Robins, Thomas; Lewis, Toby; Mukherjee, Bhramar; Ramirez, Erminia; Rowe, Zachary; Brakefield-Caldwell, Wilma

    2014-01-01

    This study characterizes the use of HEPA air filters provided to 89 households participating in an intervention study investigating the respiratory health of children with asthma. Freestanding filters were placed in the child's bedroom and monitored continuously for nearly a year in each household. Filter use was significantly affected by study phase, season and monitoring week. During the “intensive” weeks when a community education worker and a field technician visited the household, the use rate averaged 70±33%. During season-long “non-intensive” periods between seasonal visits, use dropped to 34±30%. Filter use rapidly decreased during the 3 to 4 weeks following each intensive, was slightly higher in spring, summer, and in the evening and at night when the child was likely to be home, although households did not follow consistent diurnal patterns. While participants expressed an understanding of the benefits of filter use and reported good experiences with them, use rates were low, particularly during unobserved non-intensive periods. The provision of freestanding air filters to individuals or households must be considered an active intervention that requires monitoring and evaluation, otherwise unknown and unexpected patterns of filter use may alter and possibly bias results due to exposure misclassification. PMID:24436726

  6. Tailoring Mechanically Robust Poly(m-phenylene isophthalamide) Nanofiber/nets for Ultrathin High-Efficiency Air Filter.

    PubMed

    Zhang, Shichao; Liu, Hui; Yin, Xia; Li, Zhaoling; Yu, Jianyong; Ding, Bin

    2017-01-11

    Effective promotion of air filtration applications proposed for fibers requires their real nanoscale diameter, optimized pore structure, and high service strength; however, creating such filter medium has proved to be a tremendous challenge. This study first establishes a strategy to design and fabricate novel poly(m-phenylene isophthalamide) nanofiber/nets (PMIA NF/N) air filter via electrospinning/netting. Our strategy results in generation of a bimodal structure including a scaffold of nanofibers and abundant two-dimensional ultrathin (~20 nm) nanonets to synchronously construct PMIA filters by combining solution optimization, humidity regulation, and additive inspiration. Benefiting from the structural features including the true nanoscale diameter, small pore size, high porosity, and nets bonding contributed by the widely distributed nanonets, our PMIA NF/N filter exhibits the integrated properties of superlight weight (0.365 g m(-2)), ultrathin thickness (~0.5 μm), and high tensile strength (72.8 MPa) for effective air filtration, achieving the ultra-low penetration air filter level of 99.999% and low pressure drop of 92 Pa for 300-500 nm particles by sieving mechanism. The successful synthesis of PMIA NF/N would not only provide a promising medium for particle filtration, but also develop a versatile platform for exploring the application of nanonets in structural enhancement, separation and purification.

  7. Tailoring Mechanically Robust Poly(m-phenylene isophthalamide) Nanofiber/nets for Ultrathin High-Efficiency Air Filter

    NASA Astrophysics Data System (ADS)

    Zhang, Shichao; Liu, Hui; Yin, Xia; Li, Zhaoling; Yu, Jianyong; Ding, Bin

    2017-01-01

    Effective promotion of air filtration applications proposed for fibers requires their real nanoscale diameter, optimized pore structure, and high service strength; however, creating such filter medium has proved to be a tremendous challenge. This study first establishes a strategy to design and fabricate novel poly(m-phenylene isophthalamide) nanofiber/nets (PMIA NF/N) air filter via electrospinning/netting. Our strategy results in generation of a bimodal structure including a scaffold of nanofibers and abundant two-dimensional ultrathin (~20 nm) nanonets to synchronously construct PMIA filters by combining solution optimization, humidity regulation, and additive inspiration. Benefiting from the structural features including the true nanoscale diameter, small pore size, high porosity, and nets bonding contributed by the widely distributed nanonets, our PMIA NF/N filter exhibits the integrated properties of superlight weight (0.365 g m‑2), ultrathin thickness (~0.5 μm), and high tensile strength (72.8 MPa) for effective air filtration, achieving the ultra-low penetration air filter level of 99.999% and low pressure drop of 92 Pa for 300–500 nm particles by sieving mechanism. The successful synthesis of PMIA NF/N would not only provide a promising medium for particle filtration, but also develop a versatile platform for exploring the application of nanonets in structural enhancement, separation and purification.

  8. Tailoring Mechanically Robust Poly(m-phenylene isophthalamide) Nanofiber/nets for Ultrathin High-Efficiency Air Filter

    PubMed Central

    Zhang, Shichao; Liu, Hui; Yin, Xia; Li, Zhaoling; Yu, Jianyong; Ding, Bin

    2017-01-01

    Effective promotion of air filtration applications proposed for fibers requires their real nanoscale diameter, optimized pore structure, and high service strength; however, creating such filter medium has proved to be a tremendous challenge. This study first establishes a strategy to design and fabricate novel poly(m-phenylene isophthalamide) nanofiber/nets (PMIA NF/N) air filter via electrospinning/netting. Our strategy results in generation of a bimodal structure including a scaffold of nanofibers and abundant two-dimensional ultrathin (~20 nm) nanonets to synchronously construct PMIA filters by combining solution optimization, humidity regulation, and additive inspiration. Benefiting from the structural features including the true nanoscale diameter, small pore size, high porosity, and nets bonding contributed by the widely distributed nanonets, our PMIA NF/N filter exhibits the integrated properties of superlight weight (0.365 g m−2), ultrathin thickness (~0.5 μm), and high tensile strength (72.8 MPa) for effective air filtration, achieving the ultra-low penetration air filter level of 99.999% and low pressure drop of 92 Pa for 300–500 nm particles by sieving mechanism. The successful synthesis of PMIA NF/N would not only provide a promising medium for particle filtration, but also develop a versatile platform for exploring the application of nanonets in structural enhancement, separation and purification. PMID:28074880

  9. [Design, equipment, and management for air conditioning in operating room].

    PubMed

    Fuji, Kumiko; Mizuno, Ju

    2011-11-01

    In order to maintain air cleanliness in the operating room (OR) permanently, air exchange rate in the OR should be more than 15 times x hr(-1), the laminar air flow should be kept, and the numbers of the persons in the OR and the numbers of opening and closing OR door should be limited. High efficiency particulate air (HEPA) filter is effective in collection and removal of airborne microbes, and is used in the biological clean room. We need to design, equip, and manage the OR environment according to Guideline for Design and Operation of Hospital HVAC Systems HEAS-02-2004 established by Healthcare Engineering Association of Japan and Guideline for Prevention of Surgical Site Infection (SSI) established by the Center for Disease Control and Prevention (CDC) in the USA.

  10. [Progress of biological air filter (BAF) development in manned spacecraft cabin].

    PubMed

    Tang, Yong-kang; Guo, Shuang-sheng; Ai, Wei-dang

    2005-06-01

    The contaminants originating from human metabolism, material off-gassing and waste processing, may influence human health and the growth and development of higher plants when they accumulate at some degree in the spacecraft cabin. So the contaminants concentrations must be controlled below the spacecraft maximum allowable concentration (SMAC). For the long manned space missions and planetary habitation, biological technique is available for the removal of the contaminants. The biological air filter, BAF, is a system that degrades the contaminants into carbon dioxide, water and salts. It holds many advantages such as small weight and volume, low power consumption, easy maintenance and good working performance under the condition of microgravity. Its wide application will be seen in the space field in near future.

  11. Dose- and time-dependent effects of phenobarbital on gene expression profiling in human hepatoma HepaRG cells

    SciTech Connect

    Lambert, Carine B.; Spire, Catherine Claude, Nancy; Guillouzo, Andre

    2009-02-01

    Phenobarbital (PB) induces or represses a wide spectrum of genes in rodent liver. Much less is known about its effects in human liver. We used pangenomic cDNA microarrays to analyze concentration- and time-dependent gene expression profile changes induced by PB in the well-differentiated human HepaRG cell line. Changes in gene expression profiles clustered at specific concentration ranges and treatment times. The number of correctly annotated genes significantly modulated by at least three different PB concentration ranges (spanning 0.5 to 3.2 mM) at 20 h exposure amounted to 77 and 128 genes (p {<=} 0.01) at 2- and 1.8-fold filter changes, respectively. At low concentrations (0.5 and 1 mM), PB-responsive genes included the well-recognized CAR- and PXR-dependent responsive cytochromes P450 (CYP2B6, CYP3A4), sulfotransferase 2A1 and plasma transporters (ABCB1, ABCC2), as well as a number of genes critically involved in various metabolic pathways, including lipid (CYP4A11, CYP4F3), vitamin D (CYP24A1) and bile (CYP7A1 and CYP8B1) metabolism. At concentrations of 3.2 mM or higher after 20 h, and especially 48 h, increased cytotoxic effects were associated with disregulation of numerous genes related to oxidative stress, DNA repair and apoptosis. Primary human hepatocyte cultures were also exposed to 1 and 3.2 mM PB for 20 h and the changes were comparable to those found in HepaRG cells treated under the same conditions. Taken altogether, our data provide further evidence that HepaRG cells closely resemble primary human hepatocytes and provide new information on the effects of PB in human liver. These data also emphasize the importance of investigating dose- and time-dependent effects of chemicals when using toxicogenomic approaches.

  12. Indium phosphide all air-gap Fabry-Pérot filters for near-infrared spectroscopic applications

    NASA Astrophysics Data System (ADS)

    Ullah, A.; Butt, M. A.; Fomchenkov, S. A.; Khonina, S. N.

    2016-08-01

    Food quality can be characterized by noninvasive techniques such as spectroscopy in the Near Infrared wavelength range. For example, 930 -1450 nm wavelength range can be used to detect diseases and differentiate between meat samples. Miniaturization of such NIR spectrometers is useful for quick and mobile characterization of food samples. Spectrometers can be miniaturized, without compromising the spectral resolution, using Fabry-Pérot (FP) filters consisting of two highly reflecting mirrors with a central cavity in between. The most commonly used mirrors in the design of FP filters are Distributed Bragg Reflections (DBRs) consisting of alternating high and low refractive index material pairs, due to their high reflectivity compared to metal mirrors. However, DBRs have high reflectivity for a selected range of wavelengths known as the stopband of the DBR. This range is usually much smaller than the sensitivity range of the spectrometer detector. Therefore, a bandpass filter is usually required to restrict wavelengths outside the stopband of the FP DBRs. Such bandpass filters are difficult to design and implement. Alternatively, high index contrast materials must be can be used to broaden the stopband width of the FP DBRs. In this work, Indium phosphide all air-gap filters are proposed in conjunction with InGaAs based detectors. The designed filter has a wide stopband covering the entire InGaAs detector sensitivity range. The filter can be tuned in the 950-1450 nm with single mode operation. The designed filter can hence be used for noninvasive meat quality control.

  13. The impact of mass flow and masking on the pressure drop of air filter in heavy-duty diesel engine

    NASA Astrophysics Data System (ADS)

    Hoseeinzadeh, Sepideh; Gorji-Bandpy, Mofid

    2012-04-01

    This paper presents a computational fluid dynamics (CFD) calculation approach to predict and evaluate the impact of the mass-flow inlet on the pressure drop of turbocharger`s air filtfer in heavy-duty diesel engine. The numerical computations were carried out using a commercial CFD program whereas the inlet area of the air filter consisted of several holes connected to a channel. After entering through the channel, the air passes among the holes and enters the air filter. The effect of masking holes and hydraulic diameter is studied and investigated on pressure drop. The results indicate that pressure drop increase with decreasing of hydraulic diameter and masking of the holes has considerable affect on the pressure drop.

  14. High volume air sampler for environmental nanoparticles using a sharp-cut inertial filter combined with an impactor

    NASA Astrophysics Data System (ADS)

    Zhang, Tong; Zhao, Tianren; Takahashi, Hideaki; Hata, Mitsuhiko; Toriba, Akira; Ikeda, Takuji; Otani, Yoshio; Furuuchi, Masami

    2017-02-01

    A multi-nozzle layered mesh inertial filter, developed by the authors based on inertial filter technology for separating ultrafine particles (UFPs) at a moderate pressure drop, was investigated in an attempt to improve the steepness of the separation efficiency curve by combining an inertial filter and an impactor. In this system, the separation curves overlap each other, while maintaining about a 100 nm difference in cutoff size d p50. Such a combination, which we refer to as a ‘hybrid inertial filter’, was validated for a single nozzle geometry. Using a multi nozzle geometry, it was scaled up to a high volume air sampling flow rate of 400 l min-1 at a pressure drop of  <15 kPa. An air sampling unit designed for a commercial portable high volume air sampler, consisting of a multi-cyclone (d p50  =  1 µm) and a hybrid inertial filer (d p50  =  130 nm), was devised and its performance was compared with that for conventional air samplers. The scaled up version of the hybrid inertial filter using multi-nozzle geometry was confirmed. The features of the hybrid inertial filter included the suppression of the bouncing of particles with sizes  >300 nm, a steeper collection efficiency curve and less pressure drop than those of a previous type of inertial filter. The ambient PM0.13 evaluated for the present unit was found to be in good agreement with values obtained for 2 different types of cascade air samplers.

  15. Experimental Study on Ultrafine Particle Removal Performance of Portable Air Cleaners with Different Filters in an Office Room

    PubMed Central

    Ma, Huan; Shen, Henggen; Shui, Tiantian; Li, Qing; Zhou, Liuke

    2016-01-01

    Size- and time-dependent aerodynamic behaviors of indoor particles, including PM1.0, were evaluated in a school office in order to test the performance of air-cleaning devices using different filters. In-situ real-time measurements were taken using an optical particle counter. The filtration characteristics of filter media, including single-pass efficiency, volume and effectiveness, were evaluated and analyzed. The electret filter (EE) medium shows better initial removal efficiency than the high efficiency (HE) medium in the 0.3–3.5 μm particle size range, while under the same face velocity, the filtration resistance of the HE medium is several times higher than that of the EE medium. During service life testing, the efficiency of the EE medium decreased to 60% with a total purifying air flow of 25 × 104 m3/m2. The resistance curve rose slightly before the efficiency reached the bottom, and then increased almost exponentially. The single-pass efficiency of portable air cleaner (PAC) with the pre-filter (PR) or the active carbon granule filter (CF) was relatively poor. While PAC with the pre-filter and the high efficiency filter (PR&HE) showed maximum single-pass efficiency for PM1.0 (88.6%), PAC with the HE was the most effective at removing PM1.0. The enhancement of PR with HE and electret filters augmented the single-pass efficiency, but lessened the airflow rate and effectiveness. Combined with PR, the decay constant of large-sized particles could be greater than for PACs without PR. Without regard to the lifetime, the electret filters performed better with respect to resource saving and purification improvement. A most penetrating particle size range (MPPS: 0.4–0.65 μm) exists in both HE and electret filters; the MPPS tends to become larger after HE and electret filters are combined with PR. These results serve to provide a better understanding of the indoor particle removal performance of PACs when combined with different kinds of filters in school

  16. Approach to Cultural Asset Preservation "Enzyme Filter Media Has Bactericidal Effect and Bacteriostasis Effect in Air Phase"

    NASA Astrophysics Data System (ADS)

    Isomae, Kazuro

    Enzyme air-filter media according to the bactericidal effect as an environmental green technology acquired the high appraisal and the result in the domestic and foreign clean room and the air conditioning field. The mechanism of this enzyme technology, safety, and the bactericidal effect in the real environment are discussed by using the electron microscopic picture etc. And it proposes to apply these technologies to the cultural asset preservation.

  17. Disk filter

    DOEpatents

    Bergman, Werner

    1986-01-01

    An electric disk filter provides a high efficiency at high temperature. A hollow outer filter of fibrous stainless steel forms the ground electrode. A refractory filter material is placed between the outer electrode and the inner electrically isolated high voltage electrode. Air flows through the outer filter surfaces through the electrified refractory filter media and between the high voltage electrodes and is removed from a space in the high voltage electrode.

  18. Disk filter

    DOEpatents

    Bergman, W.

    1985-01-09

    An electric disk filter provides a high efficiency at high temperature. A hollow outer filter of fibrous stainless steel forms the ground electrode. A refractory filter material is placed between the outer electrode and the inner electrically isolated high voltage electrode. Air flows through the outer filter surfaces through the electrified refractory filter media and between the high voltage electrodes and is removed from a space in the high voltage electrode.

  19. Semi-volatile organic compounds in heating, ventilation, and air-conditioning filter dust in retail stores.

    PubMed

    Xu, Y; Liang, Y; Urquidi, J R; Siegel, J A

    2015-02-01

    Retail stores contain a wide range of products that can emit a variety of indoor pollutants. Among these chemicals, phthalate esters and polybrominated diphenyl ethers (PBDEs) are two important categories of semi-volatile organic compounds (SVOCs). Filters in heating, ventilation, and air-conditioning (HVAC) system collect particles from large volumes of air and thus potentially provide spatially and temporally integrated SVOC concentrations. This study measured six phthalate and 14 PBDE compounds in HVAC filter dust in 14 retail stores in Texas and Pennsylvania, United States. Phthalates and PBDEs were widely found in the HVAC filter dust in retail environment, indicating that they are ubiquitous indoor pollutants. The potential co-occurrence of phthalates and PBDEs was not strong, suggesting that their indoor sources are diverse. The levels of phthalates and PBDEs measured in HVAC filter dust are comparable to concentrations found in previous investigations of settled dust in residential buildings. Significant correlations between indoor air and filter dust concentrations were found for diethyl phthalate, di-n-butyl phthalate, and benzyl butyl phthalate. Reasonable agreement between measurements and an equilibrium model to describe SVOC partitioning between dust and gas-phase is achieved.

  20. EFFECT OF VENTILATION SYSTEMS AND AIR FILTERS ON DECAY RATES OF PARTICLES PRODUCED BY INDOOR SOURCES IN AN OCCUPIED TOWNHOUSE

    EPA Science Inventory

    Several studies have shown the importance of particle losses in real homes due to deposition and filtration; however, none have quantitatively shown the impact of using a central forced air fan and in-duct filter on particle loss rates. In an attempt to provide such data, we me...

  1. 42 CFR 84.1143 - Dust, fume, and mist air-purifying filter tests; performance requirements; general.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Dust, fume, and mist air-purifying filter tests; performance requirements; general. 84.1143 Section 84.1143 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL...

  2. Mixed cellulose ester filter as a separator for air-diffusion cathode microbial fuel cells.

    PubMed

    Wang, Zejie; Lim, Bongsu

    2017-04-01

    Separator is important to prevent bio-contamination of the catalyst layer of air-diffusion cathode microbial fuel cells (MFCs). Mixed cellulose ester filter (MCEF) was examined as a separator for an air-cathode MFC in the present study. The MCEF-MFC produced a maximum power density of 780.7 ± 18.7 mW/m(2), which was comparable to 770.9 ± 35.9 mW/m(2) of MFC with Nafion membrane (NFM) as a separator. Long-term examination demonstrated a more stable performance of the MCEF-MFC than NFM-MFC. After 25 cycles, the maximum voltage of the MCEF-MFC decreased by only 1.3% from 425.1 ± 4.3 mV (initial 5 cycles) to 419.5 ± 2.3 mV (last 5 cycles). However, it was decreased by 9.1% from 424.8 ± 5.7 to 386 ± 2.5 mV for the NFM-MFC. The coulombic efficiency (CE) of the MCEF-MFC did not change (from 3.11 ± 0.09% to 3.13 ± 0.02%), while it decreased by 9.12% from 3.18 ± 0.04% to 2.89 ± 0.02% for the NFM-MFC. The MCEF separator was with less biofouling than the NFM separator over 60 days' operation, which might be the reason for the more table long-term performance of the MCEF-MFC. The results demonstrated that MCEF was feasible as a separator to set up good-performing and cost-effective air-diffusion cathode MFC.

  3. High efficiency filter systems -- General observations, 1992--1993. Status report

    SciTech Connect

    Mauzy, A.; Mokler, B.V.; Scripsick, R.C.

    1994-05-01

    Reviews of air emission control systems have been conducted at selected facilities supported by the Department of Energy (DOE) Office of Nuclear Energy (NE). Large High efficiency particulate air (HEPA) filtration systems and their testing received particular emphasis. Although significant differences between the sites were found, there were also several common issues. These are discussed under four general topic areas: policy development, testing multiple state systems, guidance on in-place filter testing and system supervision, and uncertainty in in-place filter testing results. Two principal conclusions have emerged from these reviews. First, there is an immediate need to develop information on how filter mechanical integrity decreases with time and use this to establish limits on filter service life. Second, there is a general need to ensure the validity of in-place filter testing results and improve testing practices. A mathematical framework for describing the effects of nonideal system features on testing results is proposed as an aid in understanding the uncertainty in in-place filter testing results.

  4. Modeling the Air Flow in the 3410 Building Filtered Exhaust Stack System

    SciTech Connect

    Recknagle, Kurtis P.; Barnett, J. Matthew; Suffield, Sarah R.

    2013-01-23

    Additional ventilation capacity has been designed for the 3410 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and will include ductwork to incorporate the new fan into the existing stack. Stack operations will involve running various two-fan combinations at any given time. The air monitoring system of the existing two-fan stack was previously found to be in compliance with the ANSI/HPS N13.1-1999 standard, however it is not known if the modified (three-fan) system will comply. Subsequently, a full-scale three-dimensional (3-D) computational fluid dynamics (CFD) model of the modified stack system has been created to examine the sampling location for compliance with the standard. The CFD modeling results show good agreement with testing data collected from the existing 3410 Building stack and suggest that velocity uniformity and flow angles will remain well within acceptance criteria when the third fan and associated ductwork is installed. This includes two-fan flow rates up to 31,840 cfm for any of the two-fan combinations. For simulation cases in which tracer gas and particles are introduced in the main duct, the model predicts that both particle and tracer gas coefficients of variance (COVs) may be larger than the acceptable 20 percent criterion of the ANSI/HPS N13.1-1999 standard for each of the two-fan, 31,840 cfm combinations. Simulations in which the tracers are introduced near the fans result in improved, though marginally acceptable, COV values for the tracers. Due to the remaining uncertainty that the stack will qualify with the addition of the third fan and high flow rates, a stationary air blender from Blender Products, Inc. is considered for inclusion in the stack system. A model of the air blender has been developed and incorporated into the CFD model. Simulation results from the CFD model that includes the air blender show striking improvements in tracer gas mixing and tracer particle

  5. Emission of poly and perfluoroalkyl substances, UV-filters and siloxanes to air from wastewater treatment plants.

    PubMed

    Shoeib, Mahiba; Schuster, Jasmin; Rauert, Cassandra; Su, Ky; Smyth, Shirley-Anne; Harner, Tom

    2016-11-01

    The potential of wastewater treatment plants (WWTPs) to act as sources of poly and perfluoroalkyl substances (PFASs), volatile methyl siloxanes (VMSs) and organic UV-filters to the atmosphere was investigated. Target compounds included: PFASs (fluorotelomer alcohols (FTOHs), perfluorooctane sulfonamides/sulfonamidoethanols (FOSAs/FOSEs), perfluroalkyl sulfonic acids (PFSAs) and perfluroalkyl carboxylic acids (PFCAs)), cyclic VMSs (D3 to D6), linear VMSs (L3 to L5) and eight UV-filters. Emissions to air were assessed at eight WWTPs using paired sorbent-impregnated polyurethane foam passive air samplers, deployed during summer 2013 and winter 2014. Samplers were deployed on-site above the active tank and off-site as a reference. Several types of WWTPs were investigated: secondary activated sludge in urban areas (UR-AS), secondary extended aeration in towns (TW-EA) and facultative lagoons in rural areas (RU-LG). The concentrations of target compounds in air were ∼1.7-35 times higher on-site compared to the corresponding off-site location. Highest concentrations in air were observed at UR-AS sites while the lowest were at RU-LG. Higher air concentrations (∼2-9 times) were observed on-site during summer compared to winter, possibly reflecting enhanced volatilization due to higher wastewater temperatures or differences in influent wastewater concentrations. A significant positive correlation was obtained between concentrations in air and WWTP characteristics (influent flow rate and population in the catchment of the WWTP); whereas a weak negative correlation was obtained with hydraulic retention time. Emissions to air were estimated using a simplified dispersion model. Highest emissions to air were seen at the UR-AS locations. Emissions to air (g/year/tank) were highest for VMSs (5000-112,000) followed by UV-filters (16-2000) then ΣPFASs (10-110).

  6. Air flow resistance of three heat and moisture exchanging filter designs under wet conditions: implications for patient safety.

    PubMed

    Morgan-Hughes, N J; Mills, G H; Northwood, D

    2001-08-01

    Heat and moisture exchanging filters (HMEFs) can be blocked by secretions. We have studied HMEF performance under wet conditions to see which particular design features predispose to this complication. Dar Hygrobac-S (composite felt filter and cellulose exchanger), Dar Hygroster (composite pleated ceramic membrane and cellulose exchanger) and Pall BB22-15 (pleated ceramic membrane) HMEFs were tested. Saline retention, saline concealment, and changes in air flow resistance when wet were assessed. The cellulose exchanger in the composite Hygrobac-S and Hygroster retained saline, producing a 'tampon' effect, associated with bi-directional air flow resistances in excess of the international standard of a 5 cm H(2)O pressure drop at 60 litre min(-1) air flow. Furthermore, high air flow resistances occurred before free saline was apparent within the transparent filter housing. The pleat only BB22-15 showed a significant increase in expiratory air flow resistance, but only after the presence of saline was apparent. These data imply that composite HMEFs with cellulose exchangers are more likely to block or cause excessive work of breathing as a result of occult accumulation of patient secretions than pleat only HMEFs.

  7. The Brookhaven National Laboratory filter pack system for collection and determination of air pollutants

    SciTech Connect

    Leahy, D.F.; Klotz, P.J.; Springston, S.R.; Daum, P.H.

    1995-04-01

    A filter pack system for sampling trace constituents in the atmosphere from aircraft and ground-based measurement platforms has been developed. The system simultaneously and quantitatively collects atmospheric aerosol, nitric acid, and sulfur dioxide using three sequential filter stages. The quartz aerosol filter is routinely analyzed for sulfate, nitrate, ammonium, and hydrogen ions, and specifically for sulfuric acid. The sodium chloride filter is analyzed for nitrate ion (from collected nitric acid), and the carbonate-glycerine filter for sulfate ion (from collected sulfur dioxide). Details of the procedures used for filter preparation, sampling, extraction and analysis are given.

  8. Evaluation of Ag nanoparticle coated air filter against aerosolized virus: Anti-viral efficiency with dust loading.

    PubMed

    Joe, Yun Haeng; Park, Dae Hoon; Hwang, Jungho

    2016-01-15

    In this study, the effect of dust loading on the anti-viral ability of an anti-viral air filter was investigated. Silver nanoparticles approximately 11 nm in diameter were synthesized via a spark discharge generation system and were used as anti-viral agents coated onto a medium air filter. The pressure drop, filtration efficiency, and anti-viral ability of the filter against aerosolized bacteriophage MS2 virus particles were tested with dust loading. The filtration efficiency and pressure drop increased with dust loading, while the anti-viral ability decreased. Theoretical analysis of anti-viral ability with dust loading was carried out using a mathematical model based on that presented by Joe et al. (J. Hazard. Mater.; 280: 356-363, 2014). Our model can be used to compare anti-viral abilities of various anti-viral agents, determine appropriate coating areal density of anti-viral agent on a filter, and predict the life cycle of an anti-viral filter.

  9. Control of respirable particles in indoor air with portable air cleaners

    NASA Astrophysics Data System (ADS)

    Offermann, F. J.; Sextro, R. G.; Fisk, W. J.; Grimsrud, D. T.; Nazaroff, W. W.; Nero, A. V.; Revzan, K. L.; Yater, J.

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles using in situ chamber decay tests. Following injection of cigarette smoke in a room-size chamber, decay rates for particle concentrations were obtained for total number concentration and for number concentration by particle size with and without air cleaner operation. The size distribution of the tobacco smoke particles was log normal with a count median diameter of 0.15 μm and a geometric standard deviation of 2.0. Without air cleaner operation, the natural mass-averaged surface deposition rate of particles was observed to be 0.1 h -1. Air cleaning rates for particles were found to be negligible for several small panel-filter devices, a residential-sized ion-generator, and a pair of mixing fans. Electrostatic precipitators and extended surface filters removed particles at substantial rates, and a HEPA-type filter was most efficient air cleaner studied.

  10. Control of Respirable Particles in Indoor Air with Portable AirCleaners

    SciTech Connect

    Offermann, F.J.; Sextro, R.G.; Fisk, W.J.; Grimsrud, D.T.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.L.; Yater, J.

    1984-10-01

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles using in situ chamber decay tests. Following injection of cigarette smoke in a room-size chamber, decay rates for particle concentrations were obtained for total number concentration and for number concentration by particle size with and without air cleaner operation. The size distribution of the tobacco smoke particles was log normal with a count median diameter of 0.15 {micro}m and a geometric standard deviation of 2.0. Without air cleaner operation, the natural mass-averaged surface deposition rate of particles was observed to be 0.1 h{sup -1}. Air cleaning rates for particles were found to be negligible for several small panel-filter devices, a residential-sized ion-generator, and a pair of mixing fans. Electrostatic precipitators and extended surface filters removed particles at substantial rates, and a HEPA-type filter was the most efficient air cleaner studied.

  11. 42 CFR 84.181 - Non-powered air-purifying particulate filter efficiency level determination.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... been neutralized to the Boltzmann equilibrium state shall be used. Each filter shall be challenged with... Boltzmann equilibrium state shall be used. Each filter shall be challenged with a concentration...

  12. Highly Integrated Polysulfone/polyacrylonitrile/polyamide-6 Air Filter for Multi-level Physical Sieving Airborne Particles.

    PubMed

    Zhang, Shichao; Tang, Ning; Cao, Leitao; Yin, Xia; Yu, Jianyong; Ding, Bin

    2016-10-04

    Rational structural design involving controlled pore size, high porosity, and particle-targeted function is critical to the realization of highly efficient air filters, and the filter with absolute particle-screen ability has significant technological implications for applications including individual protection, industrial security, and environmental governance; however, it remains an ongoing challenge. In this study, we first report a facile and scalable strategy to fabricate the highly integrated polysulfone/polyacrylonitrile/polyamide-6 (PSU/PAN/PA-6) air filter for multi-level physical sieving airborne particles via sequential electrospinning. Our strategy causes the PSU microfiber (diameter of ~1 μm) layer, PAN nanofiber (diameter of ~200 nm) layer, and PA-6 nanonets (diameter of ~20 nm) layer to orderly assemble into the integrated filter with gradually varied pore structures and high porosity; thus enables the filter to work efficiently by employing different layers to cut off penetration of particles with certain size that exceeds the designed threshold level. By virtue of its elaborate gradient structure, robust hydrophobicity (WCA of ~130o), and superior mechanical property (5.6 MPa), our PSU/PAN/PA-6 filter even can filtrate the 300 nm particles with a high removal efficiency of 99.992% and a low pressure drop of 118 Pa in the way of physical sieving manner, which completely gets rid of the negative impact from high airflow speed, electret failure, and high humidity. It is expected that our highly integrated filter has wider applications for filtration and separation, and design of 3D functional structure in the future.

  13. Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems.

    PubMed

    Macintosh, David L; Myatt, Theodore A; Ludwig, Jerry F; Baker, Brian J; Suh, Helen H; Spengler, John D

    2008-11-01

    A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates.

  14. Clinical evaluation of the air removal characteristics of an oxygenator with integrated arterial filter in a minimized extracorporeal circuit.

    PubMed

    Stehouwer, Marco C; Boers, Chris; de Vroege, Roel; C Kelder, Johannes; Yilmaz, Alaaddin; Bruins, Peter

    2011-04-01

    The use of minimized extracorporeal circuits (MECC) in cardiac surgery is an important measure to increase the biocompatibility of cardiopulmonary bypass during coronary artery bypass grafting (CABG). These circuits eliminate volume storage reservoirs and bubble traps to minimize the circuit. However, the reduction in volume may increase the risk of gaseous microemboli (GME). The MECC system as used by our group consists of a venous bubble trap, centrifugal pump, and an oxygenator. To further reduce the risk of introducing GME, an oxygenator with an integrated arterial filter was developed based on the concept of minimal volume and foreign surface. We studied the air removal characteristics of this oxygenator with and without integrated arterial filter. The quantity and volume of GME were measured with precision at both the inlet and outlet of the devices. Our results showed that integration of an arterial filter into this oxygenator increased GME reducing capacity from 69.2% to 92%. Moreover, we were able to obtain data on the impact of an arterial filter on the exact size-distribution of GME entering the arterial line. The present study demonstrates that an MECC system and oxygenator with integrated arterial filter significantly reduces the volume and size of GME. The use of an integrated arterial filter in an MECC system may protect the patient from the deleterious effects of CPB and may further improve patient safety.

  15. Development of an activated carbon filter to remove NO2 and HONO in indoor air.

    PubMed

    Yoo, Jun Young; Park, Chan Jung; Kim, Ki Yeong; Son, Youn-Suk; Kang, Choong-Min; Wolfson, Jack M; Jung, In-Ha; Lee, Sung-Joo; Koutrakis, Petros

    2015-05-30

    To obtain the optimum removal efficiency of NO2 and HONO by coated activated carbon (ACs), the influencing factors, including the loading rate, metal and non-metal precursors, and mixture ratios, were investigated. The NOx removal efficiency (RE) for K, with the same loading (1.0 wt.%), was generally higher than for those loaded with Cu or Mn. The RE of NO2 was also higher when KOH was used as the K precursor, compared to other K precursors (KI, KNO3, and KMnO4). In addition, the REs by the ACs loaded with K were approximately 38-55% higher than those by uncoated ACs. Overall, the REs (above 95%) of HONO and NOx with 3% KOH were the highest of the coated AC filters that were tested. Additionally, the REs of NOx and HONO using a mixing ratio of 6 (2.5% PABA (p-aminobenzoic acid)+6% H3PO4):4 (3% KOH) were the highest of all the coatings tested (both metal and non-metal). The results of this study show that AC loaded with various coatings has the potential to effectively reduce NO2 and HONO levels in indoor air.

  16. A bench scale study of a one-step dissolution process for treating contaminated fiberglass filters

    SciTech Connect

    Policke, T.A.; Ritter, J.A.

    1995-12-01

    High efficiency mist eliminators (HEME) and high efficiency particulate air filters (HEPA) made of High fiberglass will be used at the Savannah River Site (SRS) to remove particulate matter from offgases generated during melter feed preparation and vitrification of high-level radioactive waste (HLW) at the Defense Waste Processing Facility (DWPF). These filters will be contaminated with high-level, radioactive species and also with various high-boiling organic compounds. For this reason, a process was developed at the Savannah River Technology Center (SRTC) that will dissolve the spent filters so that the residues may be recycled to the HLW tanks for eventual vitrification. This process involves boiling the filters sequentially in NaOH, HN0{sub 3} and NaOH, while contained in a stainless steal wire mesh frame assembly. The objective of this communication is to present some of the original preliminary work done by Ritter on the simple one-step dissolution process. The results from six bench-scale experiments are reported for the dissolution of an organically-fouled sample of HEME obtained from the Integrated DWPF Melter (IDMS) offgas filtration system. The preliminary effects of filter packing density, air sparging versus rotating basket agitation, fouling, and adding Triton X-405 as a dispersing agent are reported.

  17. DEVELOPMENT OF AG-1 SECTION FI ON METAL MEDIA FILTERS - 9061

    SciTech Connect

    Adamson, D; Charles A. Waggoner, C

    2008-12-09

    Development of a metal media standard (FI) for ASME AG-1 (Code on Nuclear Air and Gas Treatment) has been under way for almost ten years. This paper will provide a brief history of the development process of this section and a detailed overview of its current content/status. There have been at least two points when dramatic changes have been made in the scope of the document due to feedback from the full Committee on Nuclear Air and Gas Treatment (CONAGT). Development of the proposed section has required resolving several difficult issues associated with scope; namely, filtering efficiency, operating conditions (media velocity, pressure drop, etc.), qualification testing, and quality control/acceptance testing. A proposed version of Section FI is currently undergoing final revisions prior to being submitted for balloting. The section covers metal media filters of filtering efficiencies ranging from medium (less than 99.97%) to high (99.97% and greater). Two different types of high efficiency filters are addressed; those units intended to be a direct replacement of Section FC fibrous glass HEPA filters and those that will be placed into newly designed systems capable of supporting greater static pressures and differential pressures across the filter elements. Direct replacements of FC HEPA filters in existing systems will be required to meet equivalent qualification and testing requirements to those contained in Section FC. A series of qualification and quality assurance test methods have been identified for the range of filtering efficiencies covered by this proposed standard. Performance characteristics of sintered metal powder vs. sintered metal fiber media are dramatically different with respect to parameters like differential pressures and rigidity of the media. Wide latitude will be allowed for owner specification of performance criteria for filtration units that will be placed into newly designed systems. Such allowances will permit use of the most

  18. Permanently magnetized high gradient magnetic air filters for the nuclear industry

    SciTech Connect

    Watson, J.H.P.

    1995-11-01

    This paper describes the structure and testing of two novel permanently magnetized magnetic filters for fine radioactive material. In the first filter the holes in the filter are left open as capture proceeds which means the pressure drop builds up only slowly. This filter is not suitable for composite particles which can be broken by mechanical forces. The second filter has been changed so as to strongly capture particles composed of fine particles weakly bound together which tend to break when captured. This uses a principle of assisted capture in which coarse particles aid the capture of the fine fragments. These filters have the following characteristics: (1) no external magnet is required, (2) no external power is required, (3) small in size and portable, (4) easily interchangeable, and (5) can be cleaned without demagnetizing by using a magnetic fluid which matches the susceptibility of the captured particles.

  19. Integration of air separation membrane and coalescing filter for use on an inlet air system of an engine

    DOEpatents

    Moncelle, Michael E.

    2003-01-01

    An intake air separation system suitable for combustion air of an internal combustion engine. An air separation device of the system includes a plurality of fibers, each fiber having a tube with a permeation barrier layer on the outer surface thereof and a coalescing layer on the inner surface thereof, to restrict fluid droplets from contacting the permeation barrier layer.

  20. Development of a method for bacteria and virus recovery from heating, ventilation, and air conditioning (HVAC) filters.

    PubMed

    Farnsworth, James E; Goyal, Sagar M; Kim, Seung Won; Kuehn, Thomas H; Raynor, Peter C; Ramakrishnan, M A; Anantharaman, Senthilvelan; Tang, Weihua

    2006-10-01

    The aim of the work presented here is to study the effectiveness of building air handling units (AHUs) in serving as high volume sampling devices for airborne bacteria and viruses. An HVAC test facility constructed according to ASHRAE Standard 52.2-1999 was used for the controlled loading of HVAC filter media with aerosolized bacteria and virus. Nonpathogenic Bacillus subtilis var. niger was chosen as a surrogate for Bacillus anthracis. Three animal viruses; transmissible gastroenteritis virus (TGEV), avian pneumovirus (APV), and fowlpox virus were chosen as surrogates for three human viruses; SARS coronavirus, respiratory syncytial virus, and smallpox virus; respectively. These bacteria and viruses were nebulized in separate tests and injected into the test duct of the test facility upstream of a MERV 14 filter. SKC Biosamplers upstream and downstream of the test filter served as reference samplers. The collection efficiency of the filter media was calculated to be 96.5 +/- 1.5% for B. subtilis, however no collection efficiency was measured for the viruses as no live virus was ever recovered from the downstream samplers. Filter samples were cut from the test filter and eluted by hand-shaking. An extraction efficiency of 105 +/- 19% was calculated for B. subtilis. The viruses were extracted at much lower efficiencies (0.7-20%). Our results indicate that the airborne concentration of spore-forming bacteria in building AHUs may be determined by analyzing the material collected on HVAC filter media, however culture-based analytical techniques are impractical for virus recovery. Molecular-based identification techniques such as PCR could be used.

  1. Development of Test Protocols for International Space Station Particulate Filters

    NASA Technical Reports Server (NTRS)

    Vijayakumar, R.; Green, Robert D.; Agui, Juan H.

    2015-01-01

    Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High-Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. The filter element for this system has a non-standard cross-section with a length-to-width ratio (LW) of 6.6. A filter test setup was designed and built to meet industry testing standards. A CFD analysis was performed to initially determine the optimal duct geometry and flow configuration. Both a screen and flow straighter were added to the test duct design to improve flow uniformity and face velocity profiles were subsequently measured to confirm. Flow quality and aerosol mixing assessments show that the duct flow is satisfactory for the intended leak testing. Preliminary leak testing was performed on two different ISS filters, one with known perforations and one with limited use, and results confirmed that the testing methods and photometer instrument are sensitive enough to detect and locate compromised sections of an ISS BFE.Given the engineering constraints in designing spacecraft life support systems, it is anticipated that non-industry standard filters will be required in future designs. This work is focused on developing test protocols for testing the ISS BFE filters, but the methodology is general enough to be extended to other present and future spacecraft filters. These techniques for characterizing the test duct and perform leak testing

  2. Portable XRF analysis of occupational air filter samples from different workplaces using different samplers: final results, summary and conclusions.

    PubMed

    Harper, Martin; Pacolay, Bruce; Hintz, Patrick; Bartley, David L; Slaven, James E; Andrew, Michael E

    2007-11-01

    This paper concludes a five-year program on research into the use of a portable X-ray fluorescence (XRF) analyzer for analyzing lead in air sampling filters from different industrial environments, including mining, manufacturing and recycling. The results from four of these environments have already been reported. The results from two additional metal processes are presented here. At both of these sites, lead was a minor component of the total airborne metals and interferences from other elements were minimal. Nevertheless, only results from the three sites where lead was the most abundant metal were used in the overall calculation of method accuracy. The XRF analyzer was used to interrogate the filters, which were then subjected to acid digestion and analysis by inductively-coupled plasma optical-emission spectroscopy (ICP-OES). The filter samples were collected using different filter-holders or "samplers" where the size (diameter), depth and homogeneity of aerosol deposit varied from sampler to sampler. The aerosol collection efficiencies of the samplers were expected to differ, especially for larger particles. The distribution of particles once having entered the sampler was also expected to differ between samplers. Samplers were paired to allow the between-sampler variability to be addressed, and, in some cases, internal sampler wall deposits were evaluated and compared to the filter catch. It was found, rather surprisingly, that analysis of the filter deposits (by ICP-OES) of all the samplers gave equivalent results. It was also found that deposits on some of the sampler walls, which in some protocols are considered part of the sample, could be significant in comparison to the filter deposit. If it is concluded that wall-deposits should be analyzed, then XRF analysis of the filter can only give a minimum estimate of the concentration. Techniques for the statistical analysis of field data were also developed as part of this program and have been reported

  3. Air filters and air cleaners: Rostrum by the American Academy of Allergy, Asthma & Immunology Indoor Allergen Committee

    PubMed Central

    Sublett, James L.; Seltzer, James; Burkhead, Robert; Williams, P. Brock; Wedner, H. James; Phipatanakul, Wanda

    2010-01-01

    The allergist is generally recognized as possessing the greatest expertise in relating airborne contaminants to respiratory health, both atopic and nonatopic. Consequently, allergists are most often asked for their professional opinions regarding the appropriate use of air-cleaning equipment. This rostrum serves as a resource for the allergist and other health care professionals seeking a better understanding of air filtration. PMID:19910039

  4. An experimental approach to efficiency calibration for gamma-ray spectrometric analysis of large air particulate filters

    NASA Astrophysics Data System (ADS)

    Tomarchio, Elio

    2013-04-01

    A full-energy-peak efficiency (FEPE) calibration procedure for gamma-ray spectrometric analysis of air particulate samples collected on large filters is described herein. The experimental results are obtained for an unconventional measurement geometry, termed a "packet-sample". The sample is obtained from a large cellulose filter (45 cm×45 cm) used to collect air particulate samples that is resized to dimensions suitable for spectrometric measurements (6 cm×6 cm×0.7 cm). To determine the FEPEs, many standards were created, i.e., some filters containing a small amount of ThO2 and others containing a known amount of KCl. Efficiency curves obtained through best fits to experimental data for three high-purity germanium (HPGe) detectors, one of them for X-ray measurement, cover the energy range from 40 keV to 2600 keV. To validate the efficiency calibration procedure two experimental tests with the use of calibrated sources were conducted and, as application example, airborne concentrations of 131I (particulate matter), 134Cs and 137Cs at Palermo (Italy) in the days following the Fukushima accident in Japan were evaluated.

  5. A modified biotrickling filter for nitrification-denitrification in the treatment of an ammonia-contaminated air stream.

    PubMed

    Raboni, Massimo; Torretta, Vincenzo

    2016-12-01

    A conventional biotrickling filter for airborne ammonia nitrification has been modified, by converting the liquid sump into a biological denitrifying reactor. The biotrickling filter achieves an average ammonia removal efficiency of 92.4 %, with an empty bed retention time (EBRT) equal to 36 s and an average ammonia concentration of 54.7 mg Nm(-3) in the raw air stream. The denitrification reactor converts ammonia into inert gas N2, in addition to other important advantages connected to the alkaline character of the biochemical pathway of the denitrifying bacteria. Firstly, the trickling water crossing the denitrification reactor underwent a notable pH increase from 7.3 to 8.0 which prevented the acidic inhibition of the nitrifying bacteria due to the buildup of nitric and nitrous acids. Secondly, the pH increase created the ideal conditions for the autotrophic nitrifying bacteria. The tests proved that an ammonia removal efficiency of above 90 % can be achieved with an EBRT greater than 30 s and a volumetric load lower than 200 g NH3 m(-3) day(-1). The results of the biofilm observation by using a scanning confocal laser microscope are reported together with the identification of degrading bacteria genera in the biotrickling filter. The efficiency of the plant and its excellent operational stability highlight the effectiveness of the synergistic action between the denitrification reactor and the biotrickling filter in removing airborne ammonia.

  6. Ultra-wide tuning single channel filter based on one-dimensional photonic crystal with an air cavity

    NASA Astrophysics Data System (ADS)

    Zhao, Xiaodan; Yang, Yibiao; Chen, Zhihui; Wang, Yuncai; Fei, Hongming; Deng, Xiao

    2017-02-01

    By inserting an air cavity into a one-dimensional photonic crystal of LiF/GaSb, a tunable filter covering the whole visible range is proposed. Following consideration of the dispersion of the materials, through modulating the thickness of the air cavity, we demonstrate that a single resonant peak can shift from 416.1 to 667.3 nm in the band gap at normal incidence by means of the transfer matrix method. The research also shows that the transmittance of the channel can be maximized when the number of periodic LiF/GaSb layers on one side of the air defect layer is equal to that of the other side. When adding a period to both sides respectively, the full width at half maximum of the defect mode is reduced by one order of magnitude. This structure will provide a promising approach to fabricate practical tunable filters in the visible region with ultra-wide tuning range. Project supported by the National Natural Science Foundation of China (Nos. 61575138, 61307069, 51205273), and the Top Young Academic Leaders and the Outstanding Innovative Teams of Higher Learning Institutions of Shanxi.

  7. An evaluation of interventions for reducing the risk of PRRSV introduction to filtered farms via retrograde air movement through idle fans.

    PubMed

    Alonso, Carmen; Otake, Satoshi; Davies, Peter; Dee, Scott

    2012-06-15

    Porcine reproductive and respiratory syndrome virus (PRRSV) is an economically significant pathogen of pigs that can be transported via the airborne route out to 9.1 km. To reduce this risk, large swine facilities have started to implement systems to filter contaminated incoming air. A proposed means of air filtration failure is the retrograde movement of air (back-drafting) from the external environment into the animal air space through non-filtered points such as idle wall fans; however, this risk has not been validated. Therefore, the purpose of this study was threefold: (1) to prove that PRRSV introduction via retrograde air movement through idle fans is a true risk; (2) to determine the minimum retrograde air velocity necessary to introduce PRRSV to an animal airspace from an external source; and (3) to evaluate the efficacy of different interventions designed to reduce this risk. A retrograde air movement model was used to test a range of velocities and interventions, including a standard plastic shutter, a plastic shutter plus a canvas cover, a nylon air chute, an aluminum shutter plus an air chute and a double shutter system. Results indicated that retrograde air movement is a real risk for PRRSV introduction to a filtered air space; however, it required a velocity of 0.76 m/s. In addition, while all the interventions designed to reduce this risk were superior when compared to a standard plastic shutter, significant differences were detected between treatments.

  8. Large-scale generic test stand for testing of multiple configurations of air filters utilizing a range of particle size distributions.

    PubMed

    Giffin, Paxton K; Parsons, Michael S; Unz, Ronald J; Waggoner, Charles A

    2012-05-01

    The Institute for Clean Energy Technology (ICET) at Mississippi State University has developed a test stand capable of lifecycle testing of high efficiency particulate air filters and other filters specified in American Society of Mechanical Engineers Code on Nuclear Air and Gas Treatment (AG-1) filters. The test stand is currently equipped to test AG-1 Section FK radial flow filters, and expansion is currently underway to increase testing capabilities for other types of AG-1 filters. The test stand is capable of producing differential pressures of 12.45 kPa (50 in. w.c.) at volumetric air flow rates up to 113.3 m(3)/min (4000 CFM). Testing is performed at elevated and ambient conditions for temperature and relative humidity. Current testing utilizes three challenge aerosols: carbon black, alumina, and Arizona road dust (A1-Ultrafine). Each aerosol has a different mass median diameter to test loading over a wide range of particles sizes. The test stand is designed to monitor and maintain relative humidity and temperature to required specifications. Instrumentation is implemented on the upstream and downstream sections of the test stand as well as on the filter housing itself. Representative data are presented herein illustrating the test stand's capabilities. Digital images of the filter pack collected during and after testing is displayed after the representative data are discussed. In conclusion, the ICET test stand with AG-1 filter testing capabilities has been developed and hurdles such as test parameter stability and design flexibility overcome.

  9. Ultrafine particle removal and generation by portable air cleaners

    NASA Astrophysics Data System (ADS)

    Waring, Michael S.; Siegel, Jeffrey A.; Corsi, Richard L.

    Portable air cleaners can both remove and generate pollutants indoors. To investigate these phenomena, we conducted a two-phase investigation in a 14.75 m 3 stainless steel chamber. In the first phase, particle size-resolved (12.6-514 nm diameter) clean air delivery rates (CADR) and efficiencies were determined, as were ozone emission rates, for two high-efficiency particle arresting (HEPA) filters, one electrostatic precipitator with a fan, and two ion generators without fans. The two HEPA air cleaners had count average CADR (standard deviation) of 188 (30) and 324 (44) m 3 h -1; the electrostatic precipitator 284 (62) m 3 h -1; and the two ion generators 41 (11) and 35 (13) m 3 h -1. The electrostatic precipitator emitted ozone at a rate of 3.8±0.2 mg h -1, and the two ion generators 3.3±0.2 and 4.3±0.2 mg h -1. Ozone initiates reactions with certain unsaturated organic compounds that produce ultrafine and fine particles, carbonyls, other oxidized products, and free radicals. During the second phase, five different ion generators were operated separately in the presence of a plug-in liquid or solid air freshener, representing a strong terpene source. For air exchange rates of between 0.49 and 0.96 h -1, three ion generators acted as steady-state net particle generators in the entire measured range of 4.61-157 nm, and two generated particles in the range of approximately 10 to 39-55 nm. Terpene and aldehyde concentrations were also sampled for one ion generator, and concentrations of terpenes decreased and formaldehyde increased. Given these results, the pollutant removal benefits of ozone-generating air cleaners may be outweighed by the generation of indoor pollution.

  10. Fabrication of an anti-viral air filter with SiO₂-Ag nanoparticles and performance evaluation in a continuous airflow condition.

    PubMed

    Joe, Yun Haeng; Woo, Kyoungja; Hwang, Jungho

    2014-09-15

    In this study, SiO2 nanoparticles surface coated with Ag nanoparticles (SA particles) were fabricated to coat a medium air filter. The pressure drop, filtration efficiency, and anti-viral ability of the filter were evaluated against aerosolized bacteriophage MS2 in a continuous air flow condition. A mathematical approach was developed to measure the anti-viral ability of the filter with various virus deposition times. Moreover, two quality factors based on the anti-viral ability of the filter, and a traditional quality factor based on filtration efficiency, were calculated. The filtration efficiency and pressure drop increased with decreasing media velocity and with increasing SA particle coating level. The anti-viral efficiency also increased with increasing SA particle coating level, and decreased by with increasing virus deposition time. Consequently, SA particle coating on a filter does not have significant effects on filtration quality, and there is an optimal coating level to produce the highest anti-viral quality.

  11. Application of a high-efficiency cabin air filter for simultaneous mitigation of ultrafine particle and carbon dioxide exposures inside passenger vehicles.

    PubMed

    Lee, Eon S; Zhu, Yifang

    2014-02-18

    Modern passenger vehicles are commonly equipped with cabin air filters but their filtration efficiency for ultrafine particle (UFP) is rather low. Although setting the vehicle ventilation system to recirculation (RC) mode can reduce in-cabin UFPs by ∼ 90%, passenger-exhaled carbon dioxide (CO2) can quickly accumulate inside the cabin. Using outdoor air (OA) mode instead can provide sufficient air exchange to prevent CO2 buildup, but in-cabin UFP concentrations would increase. To overcome this dilemma, we developed a simultaneous mitigation method for UFP and CO2 using high-efficiency cabin air (HECA) filtration in OA mode. Concentrations of UFP and other air pollutants were simultaneously monitored in and out of 12 different vehicles under 3 driving conditions: stationary, on local roadways, and on freeways. Under each experimental condition, data were collected with no filter, in-use original equipment manufacturer (OEM) filter, and two types of HECA filters. The HECA filters offered an average in-cabin UFP reduction of 93%, much higher than the OEM filters (∼ 50% on average). Throughout the measurements, the in-cabin CO2 concentration remained in the range of 620-930 ppm, significantly lower than the typical level of 2500-4000 ppm observed in the RC mode.

  12. Low-Resistance Dual-Purpose Air Filter Releasing Negative Ions and Effectively Capturing PM2.5.

    PubMed

    Zhao, Xinglei; Li, Yuyao; Hua, Ting; Jiang, Pan; Yin, Xia; Yu, Jianyong; Ding, Bin

    2017-04-05

    The fatal danger of pollution due to particulate matter (PM) calls for both high-efficiency and low-resistance air purification materials, which also provide healthcare. This is however still a challenge. Herein, a low-resistance air filter capable of releasing negative ions (NIs) and efficiently capturing PM2.5 was prepared by electrospinning polyvinylidene fluoride (PVDF) fibers doped with negative ions powder (NIPs). The air-resistance of fibrous membranes decreased from 9.5 to 6 Pa (decrease of 36%) on decreasing the average fiber diameter from 1.16 to 0.41 μm. Moreover, the lower rising rate of air-resistance with reduction in pore size, for fibrous membranes with thinner fiber diameter was verified. In addition, a single PVDF/NIPs fiber was provided with strong surface potentials, due to high fluorine electronegativity, and tested using atomic force microscopy. This strong surface potential resulted in higher releasing amounts of NIs (RANIs). Interestingly, reduction of fiber diameter favored the alleviation of the shielding effects on electric field around fibers and promoted the RANIs from 798 to 1711 ions cc(-1). Moreover, by regulating the doping contents of NIPs, the RANIs increased from 1711 to 2818 ions cc(-1). The resultant fibrous membranes showed low air resistance of 40.5 Pa. Field-tests conducted in Shanghai showed stable PM2.5 purification efficiency of 99.99% at high RANIs, in the event of haze.

  13. BIOMASS CONTROL IN WASTE AIR BIOTRICKLING FILTERS BY PROTOZOAN PREDATION. (R825392)

    EPA Science Inventory

    Two protozoan species as well as an uncharacterized protozoan consortium were added to a toluene-degrading biotrickling filter to investigate protozoan predation as a means of biomass control. Wet biomass formation in 23.6-L reactors over a 77-day period was reduced from 13.875 k...

  14. 42 CFR 84.181 - Non-powered air-purifying particulate filter efficiency level determination.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... sodium chloride or equivalent solid aerosol at 25 ±5 °C and relative humidity of 30 ±10 percent that has... further decrease in efficiency. (g) The sodium chloride test aerosol shall have a particle size...-purifying particulate respirator model shall be tested for filter efficiency against: (1) A solid...

  15. 42 CFR 84.181 - Non-powered air-purifying particulate filter efficiency level determination.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... sodium chloride or equivalent solid aerosol at 25 ±5 °C and relative humidity of 30 ±10 percent that has... further decrease in efficiency. (g) The sodium chloride test aerosol shall have a particle size...-purifying particulate respirator model shall be tested for filter efficiency against: (1) A solid...

  16. 42 CFR 84.181 - Non-powered air-purifying particulate filter efficiency level determination.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... sodium chloride or equivalent solid aerosol at 25 ±5 °C and relative humidity of 30 ±10 percent that has... further decrease in efficiency. (g) The sodium chloride test aerosol shall have a particle size...-purifying particulate respirator model shall be tested for filter efficiency against: (1) A solid...

  17. 42 CFR 84.181 - Non-powered air-purifying particulate filter efficiency level determination.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... sodium chloride or equivalent solid aerosol at 25 ±5 °C and relative humidity of 30 ±10 percent that has... further decrease in efficiency. (g) The sodium chloride test aerosol shall have a particle size...-purifying particulate respirator model shall be tested for filter efficiency against: (1) A solid...

  18. Advanced Filter Technology For Nuclear Thermal Propulsion

    NASA Technical Reports Server (NTRS)

    Castillon, Erick

    2015-01-01

    The Scrubber System focuses on using HEPA filters and carbon filtration to purify the exhaust of a Nuclear Thermal Propulsion engine of its aerosols and radioactive particles; however, new technology may lend itself to alternate filtration options, which may lead to reduction in cost while at the same time have the same filtering, if not greater, filtering capabilities, as its predecessors. Extensive research on various types of filtration methods was conducted with only four showing real promise: ionization, cyclonic separation, classic filtration, and host molecules. With the four methods defined, more research was needed to find the devices suitable for each method. Each filtration option was matched with a device: cyclonic separators for the method of the same name, electrostatic separators for ionization, HEGA filters, and carcerands for the host molecule method. Through many hours of research, the best alternative for aerosol filtration was determined to be the electrostatic precipitator because of its high durability against flow rate and its ability to cleanse up to 99.99% of contaminants as small as 0.001 micron. Carcerands, which are the only alternative to filtering radioactive particles, were found to be non-existent commercially because of their status as a "work in progress" at research institutions. Nevertheless, the conclusions after the research were that HEPA filters is recommended as the best option for filtering aerosols and carbon filtration is best for filtering radioactive particles.

  19. Application of wavelet filtering and Barker-coded pulse compression hybrid method to air-coupled ultrasonic testing

    NASA Astrophysics Data System (ADS)

    Zhou, Zhenggan; Ma, Baoquan; Jiang, Jingtao; Yu, Guang; Liu, Kui; Zhang, Dongmei; Liu, Weiping

    2014-10-01

    Air-coupled ultrasonic testing (ACUT) technique has been viewed as a viable solution in defect detection of advanced composites used in aerospace and aviation industries. However, the giant mismatch of acoustic impedance in air-solid interface makes the transmission efficiency of ultrasound low, and leads to poor signal-to-noise (SNR) ratio of received signal. The utilisation of signal-processing techniques in non-destructive testing is highly appreciated. This paper presents a wavelet filtering and phase-coded pulse compression hybrid method to improve the SNR and output power of received signal. The wavelet transform is utilised to filter insignificant components from noisy ultrasonic signal, and pulse compression process is used to improve the power of correlated signal based on cross-correction algorithm. For the purpose of reasonable parameter selection, different families of wavelets (Daubechies, Symlet and Coiflet) and decomposition level in discrete wavelet transform are analysed, different Barker codes (5-13 bits) are also analysed to acquire higher main-to-side lobe ratio. The performance of the hybrid method was verified in a honeycomb composite sample. Experimental results demonstrated that the proposed method is very efficient in improving the SNR and signal strength. The applicability of the proposed method seems to be a very promising tool to evaluate the integrity of high ultrasound attenuation composite materials using the ACUT.

  20. Interlaboratory evaluation of trace element determination in workplace air filter samples by inductively coupled plasma mass spectrometry†‡

    PubMed Central

    Shulman, Stanley A.; Brisson, Michael J.; Howe, Alan M.

    2015-01-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is becoming more widely used for trace elemental analysis in the occupational hygiene field, and consequently new ICP-MS international standard procedures have been promulgated by ASTM International and ISO. However, there is a dearth of interlaboratory performance data for this analytical methodology. In an effort to fill this data void, an interlaboratory evaluation of ICP-MS for determining trace elements in workplace air samples was conducted, towards fulfillment of method validation requirements for international voluntary consensus standard test methods. The study was performed in accordance with applicable statistical procedures for investigating interlaboratory precision. The evaluation was carried out using certified 37-mm diameter mixed-cellulose ester (MCE) filters that were fortified with 21 elements of concern in occupational hygiene. Elements were spiked at levels ranging from 0.025 to 10 μg filter−1, with three different filter loadings denoted “Low”, “Medium” and “High”. Participating laboratories were recruited from a pool of over fifty invitees; ultimately twenty laboratories from Europe, North America and Asia submitted results. Triplicates of each certified filter with elemental contents at three different levels, plus media blanks spiked with reagent, were conveyed to each volunteer laboratory. Each participant was also provided a copy of the test method which each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the filters by one of three sample preparation procedures, i.e., hotplate digestion, microwave digestion or hot block extraction, which were described in the test method. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS, and to report their data in units of μg filter−1. Most interlaboratory precision estimates were acceptable for medium- and high

  1. ARRANGEMENT FOR REPLACING FILTERS

    DOEpatents

    Blomgren, R.A.; Bohlin, N.J.C.

    1957-08-27

    An improved filtered air exhaust system which may be continually operated during the replacement of the filters without the escape of unfiltered air is described. This is accomplished by hermetically sealing the box like filter containers in a rectangular tunnel with neoprene covered sponge rubber sealing rings coated with a silicone impregnated pneumatic grease. The tunnel through which the filters are pushed is normal to the exhaust air duct. A number of unused filters are in line behind the filters in use, and are moved by a hydraulic ram so that a fresh filter is positioned in the air duct. The used filter is pushed into a waiting receptacle and is suitably disposed. This device permits a rapid and safe replacement of a radiation contaminated filter without interruption to the normal flow of exhaust air.

  2. Using Empirical Mode Decomposition to Filter Out Non-turbulent Contributions to Air-Sea Fluxes

    NASA Astrophysics Data System (ADS)

    Martins, Luís Gustavo N.; Miller, Scott D.; Acevedo, Otávio C.

    2017-04-01

    A methodology based on Empirical mode decomposition (EMD) was used to filter out non-turbulent motions from measurements of atmospheric turbulence over the sea, aimed at reducing their contribution to eddy-covariance (EC) estimates of turbulent fluxes. The proposed methodology has two main objectives: (1) to provide more robust estimates of the fluxes of momentum, heat and CO_2; and (2) to reduce the number of flux intervals rejected due to non-stationarity criteria when using traditional EC data processing techniques. The method was applied to measurements from a 28-day cruise (HALOCAST 2010) in the Eastern Pacific region. Empirical mode decomposition was applied to 4-h long time series data and used to determine the cospectral gap time scale, T_{gap}. Intrinsic modes of oscillation with characteristic periods longer than the gap scale due to non-turbulent motions were assumed and filtered out. Turbulent fluxes were then calculated for sub-intervals of length T_{gap} from the filtered 4-h time series. In the HALOCAST data, the gap scale was successfully identified in 89% of the 4-h periods and had a mean of 37 s. The EMD approach resulted in the rejection of 11% of the flux intervals, which was much less than the 68% rejected when using standard filtering methods based on data non-stationarity. For momentum and sensible heat fluxes, the averaged difference in flux magnitude between the traditional and EMD approaches was small (3 and 1%, respectively). For the CO_2 flux, the magnitude of EMD flux estimates was on average 16% less than fluxes estimated from linear detrended 10-min time series. These results provide evidence that the EMD method can be used to reduce the effects of non-turbulent correlations from flux estimates.

  3. 3D Air Filtration Modeling for Nanofiber Based Filters in the Ultrafine Particle Size Range

    NASA Astrophysics Data System (ADS)

    Sambaer, Wannes; Zatloukal, Martin; Kimmer, Dusan

    2011-07-01

    In this work, novel 3D filtration model for nanofiber based filters has been proposed and tested. For the model validation purposes, filtration efficiency characteristics of two different polyurethane nanofiber based structures (prepared by the electrospinning process) were determined experimentally in the ultrafine particle size range (20-400 nm). It has been found that the proposed model is able to reasonably predict the measured filtration efficiency curves for both tested samples.

  4. Biofiltration of toluene-contaminated air using an agro by-product-based filter bed.

    PubMed

    Krishnakumar, B; Hima, A M; Haridas, Ajit

    2007-02-01

    An innovative, coir-pith-based, filter bed for degrading vapor phase toluene in a gas biofilter over 160 days without any external nutrient supply is reported in this study. Indigenous microflora present in the coir pith as well as in the aerobic sludge added at the start-up stage metabolized the toluene, and correspondingly, CO(2) was produced in the biofilter. Inlet toluene concentration in the range of 0.75 to 2.63 g/m(3) was supplied to the biofilter in short acclimation periods. The maximum elimination capacity achieved was 96.75 g/m(3) x h at 120.72 g/m(3) x h loading where around 60% was recovered as CO(2). The filter bed maintained a stable low-pressure drop (0-4 mm H(2)O), neutral pH range (6.5-7.5), and moisture content of 60-80% (w/w) throughout the period. In addition to toluene-degrading microbial community, a grazing fauna including rotifer, bacteriovoric nematode, tardigrade, and fly larvae were also present in the filter bed. The overall performance of the biofilter bed in pollutant removal and sustainability was analyzed in this study.

  5. Geostationary Coastal and Air Pollution Events (GeoCAPE) Filter Radiometer (FR)

    NASA Technical Reports Server (NTRS)

    Kotecki, Carl; Chu, Martha; Wilson, Mark; Clark, Mike; Nanan, Bobby; Matson, Liz; McBirney, Dick; Smith, Jay; Earle, Paul; Choi, Mike; Stoneking, Eric; Luu, Kequan; Swinski, J. P.; Secunda, Mark; Brall, Aron; Verma, Sanjay; Hartman, Kathy R.

    2014-01-01

    The GeoCAPE Filter Radiometer (FR) Study is a different instrument type than all of the previous IDL GeoCape studies. The customer primary goals are to keep mass, volume and cost to a minimum while meeting the science objectives and maximizing flight opportunities by fitting on the largest number of GEO accommodations possible. Minimize total mission costs by riding on a commercial GEO satellite. For this instrument type, the coverage rate, km 2 min, was significantly increased while reducing the nadir ground sample size to 250m. This was accomplished by analyzing a large 2d area for each integration period. The field of view will be imaged on a 4k x 4k detector array of 15 micrometer pixels. Each ground pixel is spread over 2 x 2 detector pixels so the instantaneous field of view (IFOV) is 2048 X 2048 ground pixels. The baseline is, for each field of view 50 sequential snapshot images are taken, each with a different filter, before indexing the scan mirror to the next IFOV. A delta would be to add additional filters.

  6. Removal of ultrafine and fine particulate matter from air by a granular bed filter.

    PubMed

    Ozis, Fethiye; Singh, Manisha; Devinny, Joseph; Sioutas, Constantinos

    2004-08-01

    The removal efficiency of granular filters packed with lava rock and sand was studied for collection of airborne particles 0.05-2.5 microm in diameter. The effects of filter depth, packing wetness, grain size, and flow rate on collection efficiency were investigated. Two packing grain sizes (0.3 and 0.15 cm) were tested for flow rates of 1.2, 2.4, and 3.6 L/min, corresponding to empty bed residence times (equal to the bulk volume of the packing divided by the airflow rate) in the granular media of 60, 30, and 20 sec, respectively. The results showed that at 1.2 L/min, dry packing with grains 0.15 cm in diameter removed more than 80% (by number) of the particles. Particle collection efficiency decreased with increasing flow rate. Diffusion was identified as the predominant collection mechanism for ultrafine particles, while the larger particles in the accumulation mode of 0.7-2.5 microm were removed primarily by gravitational settling. For all packing depths and airflow rates, particle removal efficiency was generally higher on dry packing than on wet packing for particles smaller than 0.25 microm. The results suggest that development of biological filters for fine particles is possible.

  7. Slip-Effect Functional Air Filter for Efficient Purification of PM2.5

    NASA Astrophysics Data System (ADS)

    Zhao, Xinglei; Wang, Shan; Yin, Xia; Yu, Jianyong; Ding, Bin

    2016-10-01

    Fabrication of air filtration materials (AFM) that allow air to easily flow through while retaining particles is a significant and urgent need due to the harmful airborne particulate matter pollution; however, this is still a challenging research area. Herein, we report novel slip-effect functional nanofibrous membranes with decreased air resistance (reduction rate of 40%) due to the slip flow of air molecules on the periphery of nanofibers. This was achieved through careful control over the diameters of electrospun polyacrylonitrile fibers and aperture size of fiber assembly. Fiber assembly with 86% of fiber diameters between 60–100 nm was found to be most effective for slip flow, as these diameters are close to the mean free path of air molecules (65.3 nm). Significantly, an equilibrium factor τ = df/d2 has been introduced to elucidate the effect of distance of adjacent fibers on the drag force of airflow. Furthermore, the most effective aperture size (>3.5 μm) for slip-effect has been determined. Ultimately, the new material displayed low air resistance of 29.5 Pa, high purification efficiency of 99.09%, good transmittance of 77%, and long service life. The successful fabrication of such materials can facilitate the development of high-performance AFMs for various applications.

  8. Slip-Effect Functional Air Filter for Efficient Purification of PM2.5

    PubMed Central

    Zhao, Xinglei; Wang, Shan; Yin, Xia; Yu, Jianyong; Ding, Bin

    2016-01-01

    Fabrication of air filtration materials (AFM) that allow air to easily flow through while retaining particles is a significant and urgent need due to the harmful airborne particulate matter pollution; however, this is still a challenging research area. Herein, we report novel slip-effect functional nanofibrous membranes with decreased air resistance (reduction rate of 40%) due to the slip flow of air molecules on the periphery of nanofibers. This was achieved through careful control over the diameters of electrospun polyacrylonitrile fibers and aperture size of fiber assembly. Fiber assembly with 86% of fiber diameters between 60–100 nm was found to be most effective for slip flow, as these diameters are close to the mean free path of air molecules (65.3 nm). Significantly, an equilibrium factor τ = df/d2 has been introduced to elucidate the effect of distance of adjacent fibers on the drag force of airflow. Furthermore, the most effective aperture size (>3.5 μm) for slip-effect has been determined. Ultimately, the new material displayed low air resistance of 29.5 Pa, high purification efficiency of 99.09%, good transmittance of 77%, and long service life. The successful fabrication of such materials can facilitate the development of high-performance AFMs for various applications. PMID:27748419

  9. Background culturable bacteria aerosol in two large public buildings using HVAC filters as long term, passive, high-volume air samplers.

    PubMed

    Stanley, Nicholas J; Kuehn, Thomas H; Kim, Seung Won; Raynor, Peter C; Anantharaman, Senthilvelan; Ramakrishnan, M A; Goyal, Sagar M

    2008-04-01

    Background culturable bacteria aerosols were collected and identified in two large public buildings located in Minneapolis, Minnesota and Seattle, Washington over a period of 5 months and 3 months, respectively. The installed particulate air filters in the ventilation systems were used as the aerosol sampling devices at each location. Both pre and final filters were collected from four air handing units at each site to determine the influence of location within the building, time of year, geographical location and difference between indoor and outdoor air. Sections of each loaded filter were eluted with 10 ml of phosphate buffered saline (PBS). The resulting solutions were cultured on blood agar plates and incubated for 24 h at 36 degrees C. Various types of growth media were then used for subculturing, followed by categorization using a BioLog MicroStation (Biolog, Hayward, CA, USA) and manual observation. Environmental parameters were gathered near each filter by the embedded on-site environmental monitoring systems to determine the effect of temperature, humidity and air flow. Thirty nine different species of bacteria were identified, 17 found only in Minneapolis and 5 only in Seattle. The hardy spore-forming genus Bacillus was the most commonly identified and showed the highest concentrations. A significant decrease in the number of species and their concentration occurred in the Minneapolis air handling unit supplying 100% outdoor air in winter, however no significant correlations between bacteria concentration and environmental parameters were found.

  10. Fabrication of a multi-walled carbon nanotube-deposited glass fiber air filter for the enhancement of nano and submicron aerosol particle filtration and additional antibacterial efficacy.

    PubMed

    Park, Jae Hong; Yoon, Ki Young; Na, Hyungjoo; Kim, Yang Seon; Hwang, Jungho; Kim, Jongbaeg; Yoon, Young Hun

    2011-09-01

    We grew multi-walled carbon nanotubes (MWCNTs) on a glass fiber air filter using thermal chemical vapor deposition (CVD) after the filter was catalytically activated with a spark discharge. After the CNT deposition, filtration and antibacterial tests were performed with the filters. Potassium chloride (KCl) particles (<1 μm) were used as the test aerosol particles, and their number concentration was measured using a scanning mobility particle sizer. Antibacterial tests were performed using the colony counting method, and Escherichia coli (E. coli) was used as the test bacteria. The results showed that the CNT deposition increased the filtration efficiency of nano and submicron-sized particles, but did not increase the pressure drop across the filter. When a pristine glass fiber filter that had no CNTs was used, the particle filtration efficiencies at particle sizes under 30 nm and near 500 nm were 48.5% and 46.8%, respectively. However, the efficiencies increased to 64.3% and 60.2%, respectively, when the CNT-deposited filter was used. The reduction in the number of viable cells was determined by counting the colony forming units (CFU) of each test filter after contact with the cells. The pristine glass fiber filter was used as a control, and 83.7% of the E. coli were inactivated on the CNT-deposited filter.

  11. Removal of Gross Air Embolization from Cardiopulmonary Bypass Circuits with Integrated Arterial Line Filters: A Comparison of Circuit Designs.

    PubMed

    Reagor, James A; Holt, David W

    2016-03-01

    Advances in technology, the desire to minimize blood product transfusions, and concerns relating to inflammatory mediators have lead many practitioners and manufacturers to minimize cardiopulmonary bypass (CBP) circuit designs. The oxygenator and arterial line filter (ALF) have been integrated into one device as a method of attaining a reduction in prime volume and surface area. The instructions for use of a currently available oxygenator with integrated ALF recommends incorporating a recirculation line distal to the oxygenator. However, according to an unscientific survey, 70% of respondents utilize CPB circuits incorporating integrated ALFs without a path of recirculation distal to the oxygenator outlet. Considering this circuit design, the ability to quickly remove a gross air bolus in the blood path distal to the oxygenator may be compromised. This in vitro study was designed to determine if the time required to remove a gross air bolus from a CPB circuit without a path of recirculation distal to the oxygenator will be significantly longer than that of a circuit with a path of recirculation distal to the oxygenator. A significant difference was found in the mean time required to remove a gross air bolus between the circuit designs (p = .0003). Additionally, There was found to be a statistically significant difference in the mean time required to remove a gross air bolus between Trial 1 and Trials 4 (p = .015) and 5 (p =.014) irrespective of the circuit design. Under the parameters of this study, a recirculation line distal to an oxygenator with an integrated ALF significantly decreases the time it takes to remove an air bolus from the CPB circuit and may be safer for clinical use than the same circuit without a recirculation line.

  12. A novel method for air drying aloe leaf slices by covering with filter papers as a shrink-proof layer.

    PubMed

    Kim, S A; Baek, J H; Lee, S J; Choi, S Y; Hur, W; Lee, S Y

    2009-01-01

    To prevent the shrinkage of aloe vera slices during air drying, a method utilizing a shrink-proof layer was developed. The sample was configured of whole leaf aloe slices, where 1 side or both sides were covered with filter papers as shrink-proof layers. After air drying by varying the air temperature and the slice thickness, the drying characteristics, as well as several quality factors of the dried aloe vera leaf slices, were analyzed. In the simulation of the drying curves, the modified Page model showed the best fitness, representing a diffusion-controlled drying mechanism. Nonetheless, there was a trace of a constant-rate drying period in the samples dried by the method. Shrinkage was greatly reduced, and the rehydration ratios increased by approximately 50%. Scanning electron microscopic analysis revealed that the surface structure of original fibrous form was well sustained. FT-IR characteristics showed that the dried samples could sustain aloe polysaccharide acetylation. Furthermore, the functional properties of the dried slices including water holding capacity, swelling, and fat absorption capability were improved, and polysaccharide retention levels increased by 20% to 30%. Therefore, we concluded that application of shrink-proof layers on aloe slices provides a novel way to overcome the shrinkage problems commonly found in air drying, thereby improving their functional properties with less cost. Practical Application: This research article demonstrates a novel air drying method using shrink-proof layers to prevent the shrinkage of aloe slices. We analyzed extensively the characteristics of shrinkage mechanism and physical properties of aloe flesh gels in this drying system. We concluded that this method can be a beneficial means to retain the functional properties of dried aloe, and a potential alternative to freeze drying, which is still costly.

  13. The determination of nitrogen dioxide in ambient air with free hanging filters as passive samplers, and a new calibration method using fritted bubblers.

    PubMed

    Heeres, Paul; Setiawan, Rineksa; Krol, Maarten Cornelis; Adema, Eduard Hilbrand

    2009-12-01

    This paper describes two new methods for the determination of NO(2) in the ambient air. The first method consists of free hanging filters with a diameter of 2.5 cm as passive samplers. The filters are impregnated with triethanolamine to bind NO(2). With standard colorimetrical analysis, the amount of NO(2) on the filters is determined. The second method is performed with fritted bubblers filled with Saltzman reagent, where, with a special procedure the absorption efficiencies of the bubblers are determined using ambient air, without the use of standard gases and electronic analytical instruments. The results of the bubblers are used to calibrate the free hanging filters. The two methods were applied simultaneously in the city of Yogyakarta, Indonesia. The methods are inexpensive and very well suited for use in low-budget situations. A characteristic of the free filter is the Sampling Volume, SV. This is the ratio of the amount of NO(2) on the filter and the ambient concentration. With the filter used in this study, the amount of triethanolamine and exposure time, the SV is 0.0166 m(3). The sampling rate (SR) of the filter, 4.6 cm(3)/s, is high. Hourly averaged measurements are performed for 15 hours per day in four busy streets. The measured amounts of NO(2) on the filters varied between 0.57 and 2.02 microg NO(2), at ambient air concentrations of 32 to 141 microg/m(3) NO(2). During the experiments the wind velocity was between 0.2 and 2.0 m/s, the relative humidity between 24 and 83 % and the temperature between 295 K and 311 K. These variations in weather conditions have no influence on the uptake of NO(2).

  14. Filter Efficiency and Leak Testing of Returned ISS Bacterial Filter Elements After 2.5 Years of Continuous Operation

    NASA Technical Reports Server (NTRS)

    Green, Robert D.; Agui, Juan H.; Berger, Gordon M.; Vijayakumar, R.; Perry, Jay L.

    2016-01-01

    The atmosphere revitalization equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provides the vital functions of maintaining a habitable environment for the crew as well as protecting the hardware from fouling by suspended particulate matter. Providing these functions are challenging in pressurized spacecraft cabins because no outside air ventilation is possible and a larger particulate load is imposed on the filtration system due to lack of sedimentation in reduced gravity conditions. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Adsorption (HEPA) filters deployed at multiple locations in each module. These filters are referred to as Bacteria Filter Elements (BFEs). As more experience has been gained with ISS operations, the BFE service life, which was initially one year, has been extended to two to five years, dependent on the location in the U.S. Segment. In previous work we developed a test facility and test protocol for leak testing the ISS BFEs. For this work, we present results of leak testing a sample set of returned BFEs with a service life of 2.5 years, along with particulate removal efficiency and pressure drop measurements. The results can potentially be utilized by the ISS Program to ascertain whether the present replacement interval can be maintained or extended to balance the on-ground filter inventory with extension of the lifetime of ISS to 2024. These results can also provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

  15. PM2.5 analog forecast and Kalman filter post-processing for the Community Multiscale Air Quality (CMAQ) model

    NASA Astrophysics Data System (ADS)

    Djalalova, Irina; Delle Monache, Luca; Wilczak, James

    2015-05-01

    A new post-processing method for surface particulate matter (PM2.5) predictions from the National Oceanic and Atmospheric Administration (NOAA) developmental air quality forecasting system using the Community Multiscale Air Quality (CMAQ) model is described. It includes three main components: • A real-time quality control procedure for surface PM2.5 observations; • Model post-processing at each observational site using historical forecast analogs and Kalman filtering; • Spreading the forecast corrections from the observation locations to the entire gridded domain. The methodology is tested using 12 months of CMAQ forecasts of hourly PM2.5, from December 01, 2009 through November 30, 2010. The model domain covers the contiguous USA, and model data are verified against U.S. Environmental Prediction Agency AIRNow PM2.5 observations measured at 716 stations over the CMAQ domain. The model bias is found to have a strong seasonal dependency, with a large positive bias in winter and a small bias in the summer months, and also to have a strong diurnal cycle. Five different post-processing techniques are compared, including a seven-day running mean subtraction, Kalman-filtering, analogs, and combinations of analogs and Kalman filtering. The most accurate PM2.5 forecasts have been found to be produced when using historical analogs of the hourly Kalman-filtered forecasts, referred to as KFAN. The choice of meteorological variables used in the hourly analog search is also found to have a significant effect. A monthly error analysis is computed, in each case using the remaining 11 months of the data set for the analog searches. The improvement of KFAN errors over the raw CMAQ model errors ranges from 50 to 75% for MAE and from 40 to 60% for the correlation coefficient. Since the post-processing analysis is only done at the locations where observations are available, the spreading of post-processing correction information over nearby model grid points is necessary to make

  16. Effect of ventilation systems and air filters on decay rates of particles produced by indoor sources in an occupied townhouse

    NASA Astrophysics Data System (ADS)

    Howard-Reed, Cynthia; Wallace, Lance A.; Emmerich, Steven J.

    Several studies have shown the importance of particle losses in real homes due to deposition and filtration; however, none have quantitatively shown the impact of using a central forced air fan and in-duct filter on particle loss rates. In an attempt to provide such data, we measured the deposition of particles ranging from 0.3 to 10 μm in an occupied townhouse and also in an unoccupied test house. Experiments were run with three different sources (cooking with a gas stove, citronella candle, pouring kitty litter), with the central heating and air conditioning (HAC) fan on or off, and with two different types of in-duct filters (electrostatic precipitator and ordinary furnace filter). Particle size, HAC fan operation, and the electrostatic precipitator had significant effects on particle loss rates. The standard furnace filter had no effect. Surprisingly, the type of source (combustion vs. mechanical generation) and the type of furnishings (fully furnished including carpet vs. largely unfurnished including mostly bare floor) also had no measurable effect on the deposition rates of particles of comparable size. With the HAC fan off, average deposition rates varied from 0.3 h -1 for the smallest particle range (0.3-0.5 μm) to 5.2 h -1 for particles greater than 10 μm. Operation of the central HAC fan approximately doubled these rates for particles <5 μm, and increased rates by 2 h -1 for the larger particles. An in-duct electrostatic precipitator increased the loss rates compared to the fan-off condition by factors of 5-10 for particles <2.5 μm, and by a factor of 3 for 2.5-5.0 μm particles. In practical terms, use of the central fan alone could reduce indoor particle concentrations by 25-50%, and use of an in-duct ESP could reduce particle concentrations by 55-85% compared to fan-off conditions.

  17. Biofiltration of benzene contaminated air streams using compost-activated carbon filter media

    SciTech Connect

    Zhu, L.; Kocher, W.M.; Abumaizar, R.J.

    1998-12-31

    Three laboratory-scale biofilter columns were operated for 81 days to investigate the removal of benzene from a waste gas stream. The columns contain a mixture of yard waste and sludge compost as biomedia. Different amounts of granular activated carbon (GAC) are mixed with the compost in two of the three columns to evaluate the extent to which biofilter performance can be enhanced. The effects of different operating conditions on the performance of the removal of benzene from air were evaluated. More than 90% removal efficiency was observed for an influent benzene concentration of about 75 ppm and an air flow rate of 0.3 L/min. in all 3 columns under steady-state conditions. Under most cases of shock loading conditions, such as a sudden increase in the air flow rate, or the benzene concentration in the influent, the biofilters containing GAC provided higher removal efficiencies and more stable operation than the biofilter containing compost only.

  18. Air mass 1.5 global and direct solar simulation and secondary reference cell calibration using a filtered large area pulsed solar simulator

    NASA Technical Reports Server (NTRS)

    Mueller, Robert L.

    1985-01-01

    Spectral mismatch between a solar simulator and a desired spectrum can result in nearly 20 percent measurement error in the output of photovoltaic devices. This occurs when a crystalline silicon cell monitors the intensity of an unfiltered large area pulsed solar simulator (LAPSS) simulating the ASTM air mass 1.5 direct spectrum and the test device is amorphous silicon. The LAPSS spectral irradiance is modified with readily available glass UV filters to closely match either the ASTM air mass 1.5 direct or global spectrum. Measurement error is reduced to about 1 percent when using either filter if the reference cell and test device are the same general type.

  19. Gohieria fusca (Acari: Astigmata) found in the filter dusts of air conditioners in China.

    PubMed

    Li, Chaopin; Zhan, Xiaodong; Zhao, Jinhong; Wei, Guo

    2014-10-06

    Objetivo: La Gohieria fusca (Oudemans, 1902) se reproduce en la harina de trigo, arroz, maíz, piensos, salvado de trigo y los medicamentos a base de hierbas, además de en otros productos almacenados; este ácaro puede tener una reactividad cruzada de leve a moderada con alérgenos de los ácaros del polvo domésticos, una importante fuente de alérgenos de interior asociada al asma y otras afecciones alérgicas. Los sistemas de aire acondicionado son indispensables en edificios públicos y civiles, y las pantallas de estos aparatos son los lugares donde más se acumula el polvo. Se realizó este estudio con el fin de investigar si la Gohieria fusca puede reproducirse en las pantallas de los acondicionadores de aire instalados en espacios públicos o viviendas en la ciudad de Wuhu, provincia de Anhui, China. Métodos: Se recogieron 430 muestras de polvo de los filtros de los sistemas de aire acondicionado en la cafeterías de centros educativos, mercados, hoteles y edificios civiles entre junio y septiembre de 2013, y se aisló la Gohieria fusca de dichas muestras. Resultados: Los resultados indicaron que la Gohieria fusca estaba presente en 98 de las 430 muestras (22,79%), y la tasa de reproducción fue significativa en los filtros del aire acondicionado de diferentes espacios (c2=18.294, P.

  20. Microcycle conidiation and medusa head conidiophores of aspergilli on indoor construction materials and air filters from hospitals.

    PubMed

    Ahearm, D G; Price, D; Simmons, R B; Mayo, A; Zhang, S T; Crow, S A

    2007-01-01

    Microcycle conidiation and microniche colonization by aspergilli was observed in-situ on various indoor construction and finishing materials. Microcycle conidiation, direct conidiogenesis from a conidium or spore with minimal intervening hyphal development, for several decades has been considered a survival mechanism during stress for a variety of moulds. Adhesive transparent tape mounts and bulk materials from various indoor materials, including air filters from hospitals and healthcare institutions, were transported to the laboratory for light microscopic and scanning electron microscopic observations. Additional materials were held in moist chambers over nonsterile soils and examined periodically for fungal development. Microcycle conidiation was observed usually in areas of sparse fungal development, mostly in association with isolations of members of the Aspergillus flavus-, A. versicolor-, A. niger groups. Branched conidiophores and medusa heads, more often associated with colonization by Eurotium spp., were observed on some preserved woods. These conidiogenesis processes might be factors in the survival and blooms of indoor aspergilli.

  1. A comparison of reanalysis techniques: applying optimal interpolation and Ensemble Kalman Filtering to improve air quality monitoring at mesoscale.

    PubMed

    Candiani, Gabriele; Carnevale, Claudio; Finzi, Giovanna; Pisoni, Enrico; Volta, Marialuisa

    2013-08-01

    To fulfill the requirements of the 2008/50 Directive, which allows member states and regional authorities to use a combination of measurement and modeling to monitor air pollution concentration, a key approach to be properly developed and tested is the data assimilation one. In this paper, with a focus on regional domains, a comparison between optimal interpolation and Ensemble Kalman Filter is shown, to stress pros and drawbacks of the two techniques. These approaches can be used to implement a more accurate monitoring of the long-term pollution trends on a geographical domain, through an optimal combination of all the available sources of data. The two approaches are formalized and applied for a regional domain located in Northern Italy, where the PM10 level which is often higher than EU standard limits is measured.

  2. Reducing patients’ exposures to asthma and allergy triggers in their homes: an evaluation of effectiveness of grades of forced air ventilation filters

    PubMed Central

    Minegishi, Taeko; Allen, Joseph G.; McCarthy, John F.; Spengler, John D.; MacIntosh, David L.

    2014-01-01

    Objective Many interventions to reduce allergen levels in the home are recommended to asthma and allergy patients. One that is readily available and can be highly effective is the use of high performing filters in forced air ventilation systems. Methods We conducted a modeling analysis of the effectiveness of filter-based interventions in the home to reduce airborne asthma and allergy triggers. This work used “each pass removal efficiency” applied to health-relevant size fractions of particles to assess filter performance. We assessed effectiveness for key allergy and asthma triggers based on applicable particle sizes for cat allergen, indoor and outdoor sources of particles <2.5 µm in diameter (PM2.5), and airborne influenza and rhinovirus. Results Our analysis finds that higher performing filters can have significant impacts on indoor particle pollutant levels. Filters with removal efficiencies of >70% for cat dander particles, fine particulate matter (PM2.5) and respiratory virus can lower concentrations of those asthma triggers and allergens in indoor air of the home by >50%. Very high removal efficiency filters, such as those rated a 16 on the nationally recognized Minimum Efficiency Removal Value (MERV) rating system, tend to be only marginally more effective than MERV12 or 13 rated filters. Conclusions The results of this analysis indicate that use of a MERV12 or higher performing air filter in home ventilation systems can effectively reduce indoor levels of these common asthma and allergy triggers. These reductions in airborne allergens in turn may help reduce allergy and asthma symptoms, especially if employed in conjunction with other environmental management measures recommended for allergy and asthma patients. PMID:24555523

  3. Evaluation of the Hepa Wash® treatment in pigs with acute liver failure

    PubMed Central

    2013-01-01

    Background Mortality of patients with acute liver failure (ALF) is still unacceptably high. Available liver support systems are still of limited success at improving survival. A new type of albumin dialysis, the Hepa Wash® system, was newly introduced. We evaluated the new liver support system as well as the Molecular Adsorbent Recycling System (MARS) in an ischemic porcine model of ALF. Methods In the first study animals were randomly allocated to control (n=5) and Hepa Wash (n=6) groups. In a further pilot study, two animals were treated with the MARS-system. All animals received the same medical and surgical procedures. An intraparenchymal intracranial pressure was inserted. Hemodynamic monitoring and goal-directed fluid therapy using the PiCCO system was done. Animals underwent functional end-to-side portacaval shunt and ligation of hepatic arteries. Treatment with albumin dialysis was started after fall of cerebral perfusion pressure to 45 mmHg and continued for 8 h. Results All animals in the Hepa Wash group survived the 13-hour observation period, except for one that died after stopping treatment. Four of the control animals died within this period (p=0.03). Hepa Wash significantly reduced impairment of cerebral perfusion pressure (23±2 vs. 10±3 mmHg, p=0.006) and mean arterial pressure (37±1 vs. 24±2 mmHg, p=0.006) but had no effect on intracranial pressure (14±1 vs. 15±1 mmHg, p=0.72). Hepa Wash also enhanced cardiac index (4.94±0.32 vs. 3.36±0.25 l/min/m2, p=0.006) and renal function (urine production, 1850 ± 570 vs. 420 ± 180 ml, p=0.045) and eliminated water soluble (creatinine, 1.3±0.2 vs. 3.2±0.3 mg/dl, p=0.01; ammonia 562±124 vs. 1382±92 μg/dl, p=0.006) and protein-bound toxins (nitrate/nitrite 5.54±1.57 vs. 49.82±13.27 μmol/l, p=0.01). No adverse events that could be attributed to the Hepa Wash treatment were observed. Conclusions Hepa Wash was a safe procedure and improved multiorgan system failure in pigs with ALF. The survival

  4. Evaluation of a high-efficiency, filter-bank system.

    PubMed

    Martin, Stephen B; Beamer, Bryan R; Moyer, Ernest S

    2006-04-01

    National Institute for Occupational Safety and Health (NIOSH) investigators evaluated filtration efficiencies at three U.S. Postal Service (USPS) facilities. Ventilation and filtration systems (VFSs) had been installed after the 2001 bioterrorist attacks when the USPS unknowingly processed letters laden with B. anthracis spores. The new VFS units included high-efficiency particulate air (HEPA) filters and were required by USPS contract specifications to provide an overall filtration efficiency of at least 99.97% for particles between 0.3 microm and 3.0 micro m. The USPS evaluation involved a modification of methodology used to test total filtration system efficiency in agricultural tractor cab enclosures. The modified sampling strategy not only proved effective for monitoring the total filtration system component of VFS performance but also distinguished between filtration systems performing to the high USPS performance criteria and those needing repair or replacement. The results clearly showed the importance of choosing a pair of optical particle counters that have been closely matched immediately prior to testing. The modified methodology is readily adaptable to any workplace wishing to evaluate air filtration systems, including high-efficiency systems.

  5. Air purification equipment combining a filter coated by silver nanoparticles with a nano-TiO2 photocatalyst for use in hospitals

    NASA Astrophysics Data System (ADS)

    Son Le, Thanh; Hien Dao, Trong; Nguyen, Dinh Cuong; Chau Nguyen, Hoai; Balikhin, I. L.

    2015-03-01

    X-ray diffraction, scanning electron microscopy and transmission electron microscopy showed that TiO2 particles synthesized by a sol-gel procedure exhibited uniform size about 16-20 nm. This nanopowder was deposited on a porous quartz tube (D = 74 mm, L = 418 mm, deposit density ˜16.4 mg cm-2) through an intermediate adhesive polymethylmethacrylate layer to manufacture a photocatalytic filter tube. A polypropylene pre-filter was coated with a nanosilver layer (particle size ˜20 nm) prepared by aqueous molecular solution method. An air cleaner of 250 m3 h-1 capacity equipped with this pre-filter, an electrostatic air filter, 4 photocatalytic filter tubes and 4 UV-A lamps (36 W) presented the high degradation ability for certain volatile organic compounds (VOCs), bacteria and fungi. The VOCs degradation performances of the equipment with respect to divers compounds are different: in a 10 m3 box, 91.6% of butanol was removed within 55 min, 80% of acetone within 100 min, 70.1% of diethyl ether within 120 min and only 43% of benzene was oxidized within 150 min. Over 99% of bacteria and fungi were killed after the air passage through the equipment. For application, it was placed in the intensive care room (volume of 125 m3) of E hospital in Hanoi; 69% of bacteria and 63% of fungi were killed within 6 h.

  6. Air pollution control through biotrickling filters: a review considering operational aspects and expected performance.

    PubMed

    Schiavon, Marco; Ragazzi, Marco; Rada, Elena Cristina; Torretta, Vincenzo

    2016-12-01

    The biological removal of pollutants, especially through biotrickling filters (BTFs), has recently become attractive for the low investment and operational costs and the low secondary pollution. This paper is intended to investigate the state of the art on BTF applications. After an overview on the biodegradation process and the typical parameters involved, this paper presents the analysis of a group of 16 literature studies chosen as the references for this sector. The reference studies differ from one another by the pollutants treated (volatile organic compounds [VOC], hydrogen sulphide, nitrogen oxides and trimethylamine), the geometry and size of the BTFs, and the procedures of the tests. The reference studies are analyzed and discussed in terms of the operational conditions and the results obtained, especially with respect to the removal efficiencies (REs) and the elimination capacities (ECs) of the pollutants considered. Empty bed residence time (EBRT), pollutant loading rate, temperature, pH, oxygen availability, trickling liquid flow rate, inoculum selection and biomass control strategies revealed to be the most important operational factors influencing the removal performance of a BTF.

  7. Organophosphates in aircraft cabin and cockpit air--method development and measurements of contaminants.

    PubMed

    Solbu, Kasper; Daae, Hanne Line; Olsen, Raymond; Thorud, Syvert; Ellingsen, Dag Gunnar; Lindgren, Torsten; Bakke, Berit; Lundanes, Elsa; Molander, Paal

    2011-05-01

    Methods for measurements and the potential for occupational exposure to organophosphates (OPs) originating from turbine and hydraulic oils among flying personnel in the aviation industry are described. Different sampling methods were applied, including active within-day methods for OPs and VOCs, newly developed passive long-term sample methods (deposition of OPs to wipe surface areas and to activated charcoal cloths), and measurements of OPs in high-efficiency particulate air (HEPA) recirculation filters (n = 6). In total, 95 and 72 within-day OP and VOC samples, respectively, have been collected during 47 flights in six different models of turbine jet engine, propeller and helicopter aircrafts (n = 40). In general, the OP air levels from the within-day samples were low. The most relevant OP in this regard originating from turbine and engine oils, tricresyl phosphate (TCP), was detected in only 4% of the samples (min-max HEPA-filters. Other OPs, as dibutylphenyl phosphate (DBPP) and tri-n-butyl phosphate (TnBP) originating from hydraulic oils were more prominent in the samples, illustrated by determination of TnBP in all of the within-day samples collected from airplanes (n = 76, min-max 0.02-4.1 µg m(-3)). All samples were collected under normal flight conditions. However, the TCP concentration during ground testing in an airplane that had experienced leakage of turbine oil with subsequent contamination of the cabin and cockpit air, was an order of magnitude higher as compared to after engine replacement (p = 0.02).

  8. Tracking and Classification of In-Air Hand Gesture Based on Thermal Guided Joint Filter

    PubMed Central

    Kim, Seongwan; Ban, Yuseok; Lee, Sangyoun

    2017-01-01

    The research on hand gestures has attracted many image processing-related studies, as it intuitively conveys the intention of a human as it pertains to motional meaning. Various sensors have been used to exploit the advantages of different modalities for the extraction of important information conveyed by the hand gesture of a user. Although many works have focused on learning the benefits of thermal information from thermal cameras, most have focused on face recognition or human body detection, rather than hand gesture recognition. Additionally, the majority of the works that take advantage of multiple modalities (e.g., the combination of a thermal sensor and a visual sensor), usually adopting simple fusion approaches between the two modalities. As both thermal sensors and visual sensors have their own shortcomings and strengths, we propose a novel joint filter-based hand gesture recognition method to simultaneously exploit the strengths and compensate the shortcomings of each. Our study is motivated by the investigation of the mutual supplementation between thermal and visual information in low feature level for the consistent representation of a hand in the presence of varying lighting conditions. Accordingly, our proposed method leverages the thermal sensor’s stability against luminance and the visual sensors textural detail, while complementing the low resolution and halo effect of thermal sensors and the weakness against illumination of visual sensors. A conventional region tracking method and a deep convolutional neural network have been leveraged to track the trajectory of a hand gesture and to recognize the hand gesture, respectively. Our experimental results show stability in recognizing a hand gesture against varying lighting conditions based on the contribution of the joint kernels of spatial adjacency and thermal range similarity. PMID:28106716

  9. Tracking and Classification of In-Air Hand Gesture Based on Thermal Guided Joint Filter.

    PubMed

    Kim, Seongwan; Ban, Yuseok; Lee, Sangyoun

    2017-01-17

    The research on hand gestures has attracted many image processing-related studies, as it intuitively conveys the intention of a human as it pertains to motional meaning. Various sensors have been used to exploit the advantages of different modalities for the extraction of important information conveyed by the hand gesture of a user. Although many works have focused on learning the benefits of thermal information from thermal cameras, most have focused on face recognition or human body detection, rather than hand gesture recognition. Additionally, the majority of the works that take advantage of multiple modalities (e.g., the combination of a thermal sensor and a visual sensor), usually adopting simple fusion approaches between the two modalities. As both thermal sensors and visual sensors have their own shortcomings and strengths, we propose a novel joint filter-based hand gesture recognition method to simultaneously exploit the strengths and compensate the shortcomings of each. Our study is motivated by the investigation of the mutual supplementation between thermal and visual information in low feature level for the consistent representation of a hand in the presence of varying lighting conditions. Accordingly, our proposed method leverages the thermal sensor's stability against luminance and the visual sensors textural detail, while complementing the low resolution and halo effect of thermal sensors and the weakness against illumination of visual sensors. A conventional region tracking method and a deep convolutional neural network have been leveraged to track the trajectory of a hand gesture and to recognize the hand gesture, respectively. Our experimental results show stability in recognizing a hand gesture against varying lighting conditions based on the contribution of the joint kernels of spatial adjacency and thermal range similarity.

  10. [Observation on the air-borne bacteria and ammonia (NS3) gas in laboratory animal facility with rotary heat exchanger].

    PubMed

    Obara, T; Matsuyama, M; Fujita, S; Yamauchi, C

    1979-01-01

    The number of air-borne bacteria in air ducts and barrierred laboratory animal rooms with the so-called econovent rotary heat exchanger, were checked monthly during a year by the pin-hole sumpler method for air ducts and Koch method for animal rooms. Also, concentration of ammonia was checked with the same samples by gas impinger. No significantly difference in number of air-borne bacteria was seen between before and after passing the econovent. Those passing through HEPA filter was not detected. There were more air-borne bacteria in animal rooms, outside locker room and shower room than in the corridor, utensil storage, inside locker room and pass box. No ammonia were detected in the outdoor, but exhaust air duct after passing the econovent contained very small amount of ammonia. On the other hand, high concentration of ammonia were preserved in the supplying air duct, exhaust air duct and mice and rats rooms, about 86% of ammonia in exhaust air duct returned back into the supplying air duct. No influences on reproduction in mice and rats were recognized.

  11. Radioactive Air Emissions Notice of Construction for the 105-KW Basin integrated water treatment system filter vessel sparging vent

    SciTech Connect

    Kamberg, L.D.

    1998-02-23

    This document serves as a notice of construction (NOC), pursuant to the requirements of Washington Administrative Code (WAC) 246-247-060, and as a request for approval to construct, pursuant to 40 Code of Federal Regulations (CFR) 61.07, for the Integrated Water Treatment System (IWTS) Filter Vessel Sparging Vent at 105-KW Basin. Additionally, the following description, and references are provided as the notices of startup, pursuant to 40 CFR 61.09(a)(1) and (2) in accordance with Title 40 Code of Federal Regulations, Part 61, National Emission Standards for Hazardous Air Pollutants. The 105-K West Reactor and its associated spent nuclear fuel (SNF) storage basin were constructed in the early 1950s and are located on the Hanford Site in the 100-K Area about 1,400 feet from the Columbia River. The 105-KW Basin contains 964 Metric Tons of SNF stored under water in approximately 3,800 closed canisters. This SNF has been stored for varying periods of time ranging from 8 to 17 years. The 105-KW Basin is constructed of concrete with an epoxy coating and contains approximately 1.3 million gallons of water with an asphaltic membrane beneath the pool. The IWTS, which has been described in the Radioactive Air Emissions NOC for Fuel Removal for 105-KW Basin (DOE/RL-97-28 and page changes per US Department of Energy, Richland Operations Office letter 97-EAP-814) will be used to remove radionuclides from the basin water during fuel removal operations. The purpose of the modification described herein is to provide operational flexibility for the IWTS at the 105-KW basin. The proposed modification is scheduled to begin in calendar year 1998.

  12. Design of an adapter for air-outlet filter on the M431 chemical-agent detector. Final report, September 1987-May 1988

    SciTech Connect

    Gullman, L.S.; Low, T.P.

    1990-08-01

    An adapter has been developed to allow an air filter to be easily attached and removed from the exhaust port of the M43A1 Chemical Agent Detector. The adapter is to replace a threaded coupling presently in use, provide reliable filter retention, and ease of attachment and removal. The adapter was designed for low-cost production in quantities of 100,000. Three design alternatives are presented. Production, testing, and evaluation of each design is described. An ultrasonically assembled two-part design with an internal Nitrile ring is selected. The components are injection molded of Acetal Resin.

  13. Remotely serviced filter and housing

    DOEpatents

    Ross, Maurice J.; Zaladonis, Larry A.

    1988-09-27

    A filter system for a hot cell comprises a housing adapted for input of air or other gas to be filtered, flow of the air through a filter element, and exit of filtered air. The housing is tapered at the top to make it easy to insert a filter cartridge using an overhead crane. The filter cartridge holds the filter element while the air or other gas is passed through the filter element. Captive bolts in trunnion nuts are readily operated by electromechanical manipulators operating power wrenches to secure and release the filter cartridge. The filter cartridge is adapted to make it easy to change a filter element by using a master-slave manipulator at a shielded window station.

  14. Construction and economics of a pilot/full-scale biological trickling filter reactor for the removal of volatile organic compounds from polluted air.

    PubMed

    Deshusses, M A; Webster, T S

    2000-11-01

    The design and the construction of an actual 8.7-m3 pilot/full-scale biotrickling filter for waste air treatment is described and compared with a previous conceptual scale-up of a laboratory reactor. The reactor construction costs are detailed and show that about one-half of the total reactor costs ($97,000 out of $178,000) was for personnel and engineering time, whereas approximately 20% was for monitoring and control equipment. A detailed treatment cost analysis demonstrated that, for an empty bed contact time of 90 sec, the overall treatment costs (including capital charges) were as low as $8.7/1000 m3air in the case where a nonchlorinated volatile organic compound (VOC) was treated, and $14/1000 m3air for chlorinated compounds such as CH2Cl2. Comparison of these costs with conventional air pollution control techniques demonstrates excellent perspectives for more field applications of biotrickling filters. As the specific costs of building and operating biotrickling filter reactors decrease with increasing size of the reactor, the cost benefit of biotrickling filtration is expected to increase for full technical-scale bioreactors.

  15. Air

    MedlinePlus

    ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be polluted indoors and it can ... this chart to see what things cause indoor air pollution and what things cause outdoor air pollution! Indoor ...

  16. Concentric Split Flow Filter

    NASA Technical Reports Server (NTRS)

    Stapleton, Thomas J. (Inventor)

    2015-01-01

    A concentric split flow filter may be configured to remove odor and/or bacteria from pumped air used to collect urine and fecal waste products. For instance, filter may be designed to effectively fill the volume that was previously considered wasted surrounding the transport tube of a waste management system. The concentric split flow filter may be configured to split the air flow, with substantially half of the air flow to be treated traveling through a first bed of filter media and substantially the other half of the air flow to be treated traveling through the second bed of filter media. This split flow design reduces the air velocity by 50%. In this way, the pressure drop of filter may be reduced by as much as a factor of 4 as compare to the conventional design.

  17. Nanoparticle filtration performance of NIOSH-certified particulate air-purifying filtering facepiece respirators: evaluation by light scattering photometric and particle number-based test methods.

    PubMed

    Rengasamy, Samy; Eimer, Benjamin C

    2012-01-01

    National Institute for Occupational Safety and Health (NIOSH) certification test methods employ charge neutralized NaCl or dioctyl phthalate (DOP) aerosols to measure filter penetration levels of air-purifying particulate respirators photometrically using a TSI 8130 automated filter tester at 85 L/min. A previous study in our laboratory found that widely different filter penetration levels were measured for nanoparticles depending on whether a particle number (count)-based detector or a photometric detector was used. The purpose of this study was to better understand the influence of key test parameters, including filter media type, challenge aerosol size range, and detector system. Initial penetration levels for 17 models of NIOSH-approved N-, R-, and P-series filtering facepiece respirators were measured using the TSI 8130 photometric method and compared with the particle number-based penetration (obtained using two ultrafine condensation particle counters) for the same challenge aerosols generated by the TSI 8130. In general, the penetration obtained by the photometric method was less than the penetration obtained with the number-based method. Filter penetration was also measured for ambient room aerosols. Penetration measured by the TSI 8130 photometric method was lower than the number-based ambient aerosol penetration values. Number-based monodisperse NaCl aerosol penetration measurements showed that the most penetrating particle size was in the 50 nm range for all respirator models tested, with the exception of one model at ~200 nm size. Respirator models containing electrostatic filter media also showed lower penetration values with the TSI 8130 photometric method than the number-based penetration obtained for the most penetrating monodisperse particles. Results suggest that to provide a more challenging respirator filter test method than what is currently used for respirators containing electrostatic media, the test method should utilize a sufficient number

  18. Enrichment of hepatocytes in a HepaRG culture using spatially selective photodynamic treatment

    NASA Astrophysics Data System (ADS)

    Bednarkiewicz, Artur; Rodrigues, Robim M.; Whelan, Maurice P.

    2010-03-01

    The human hepatoma HepaRG cell line is an in vitro cell model that is becoming an important tool in drug metabolism, hepatotoxicity, genotoxicity, and enzyme induction studies. The cells are highly proliferative during their undifferentiated state but once committed, they differentiate into two distinctly different cell types, namely, hepatocyte-like and biliary epithelial-like cells. The presence of the latter in the cell culture is considered to be a drawback of the cell model. Since the proliferating undifferentiated HepaRG cells have a bipotent character, the only way to improve the content ratio of hepatic versus biliary cells of differentiated HepaRG cells is to eradicate biliary cells in situ, in a way that free surface space does not become available and thus no transdifferentiation can occur. Spatially selective photodynamic therapy has proven to be effective for that purpose. First, all the cells were administered aminolevulinic acid (δ-ALA) to stimulate the synthesis of protoporphyrin IX (PpIX), a naturally occurring photosensitizer. Then, the biliary cells were automatically identified and outlined by bright-field image processing. Last, UV light patterns were projected onto the epithelial cells alone by a spatial light modulation device connected to an optical microscope; therefore, only these cells were destroyed by photodynamic therapy.

  19. Application of modern anticoincidence (AC) system in HPGe γ-spectrometry for the detection limit lowering of the radionuclides in air filters.

    PubMed

    Długosz-Lisiecka, Magdalena

    2017-04-01

    The use of active and passive shields can substantially reduce the Minimum Detectable Activity (MDA) of the γ-ray counting systems, rejecting events induced by cosmic-rays or by environmental radioactivity. However, the size and geometry of the samples lead to limitations in the background reduction in routine measurements. The Minimum Detectable Activity (MDA) values for low energy of γ-ray emitting radionuclides (<200 keV) deposited in three typical air filter geometries have been compared for anticoincidence and single HPGe detector mode of γ-spectrometry systems. The relative increase in the Figure Of Merit (FOM) values from to 10-37% has been achieved for AC counting mode for radionuclides of (210)Pb, (234)Th, (235)U and (226)Ra deposited on the three kinds of air filters.

  20. Results of inspection and cleaning of two radionuclide air-sampling systems based on the requirements of ANSI/HPS N13.1-1999.

    PubMed

    Barnett, J M; Ballinger, M Y; Gervais, T L; Douglas, D D; Edwards, D L

    2004-04-01

    The Pacific Northwest National Laboratory inspected and cleaned two radionuclide air-sampling systems that continuously monitor radioactive air emissions from research and development facilities. The inspection and cleaning was performed to evaluate effective methods and potential cost impacts of maintenance requirements in the revised American National Standard Institute standard Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities. The standard requires at least annual inspections of sampling systems followed by cleaning if deposits are visible. During 2001 and 2002, inspections were performed leaving the sampling systems in place and inserting videoscope cables into different access points to allow viewing of the inside and outside of sampling manifolds and transport lines. Cleaning was performed on one of the systems by disconnecting and extracting the sampling manifold, then washing it with de-ionized water and scrub brushes. The wash water was analyzed for radioactivity and solids. Results of the inspection showed greater deposition in one of the systems than would be expected by a High Efficiency Particulate Air (HEPA) filtered exhaust stream, possibly due to accumulation of dust from a short period when unfiltered air was exhausted from construction areas. The second system was also downstream of HEPA filters and appeared much cleaner. The videoscope was a useful and cost-effective tool and provided a better view than could be obtained with the naked eye. However, because even small amounts of deposition were made visible with the videoscope, clarification is needed in defining when probe washing is merited, particularly in existing sampling systems whose design is not conducive to easy removal and cleaning.

  1. Control of respirable particles and radon progeny with portable air cleaners

    SciTech Connect

    Offermann, F.J.; Sextro, R.G.; Fisk, W.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.L.; Yater, J.

    1984-02-01

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles and radon progeny. Following injection of cigarette smoke and radon in a room-size chamber, decay rates for particles and radon progeny concentrations were measured with and without air cleaner operation. Particle concentrations were obtained for total number concentration and for number concentration by particle size. In tests with no air cleaner the natural decay rate for cigarette smoke was observed to be 0.2 hr/sup -1/. Air cleaning rates for particles were found to be negligible for several small panel-filters, a residential ion-generator, and a pair of mixing fans. The electrostatic precipitators and extended surface filters tested had significant particle removal rates, and a HEPA-type filter was the most efficient air cleaner. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in removing radon progeny. At low particle concentrations plateout of the unattached radon progeny is an important removal mechanism. Based on data from these tests, the plateout rate for unattached progeny was found to be 15 hr/sup -1/. The unattached fraction and the overall removal rate due to deposition of attached and unattached nuclides have been estimated for each radon decay product as a function of particle concentration. While air cleaning can be effective in reducing total radon progeny, concentrations of unattached radon progeny can increase with increasing air cleaning. 39 references, 26 figures, 9 tables.

  2. Remotely serviced filter and housing

    DOEpatents

    Ross, M.J.; Zaladonis, L.A.

    1987-07-22

    A filter system for a hot cell comprises a housing adapted for input of air or other gas to be filtered, flow of the air through a filter element, and exit of filtered air. The housing is tapered at the top to make it easy to insert a filter cartridge holds the filter element while the air or other gas is passed through the filter element. Captive bolts in trunnion nuts are readily operated by electromechanical manipulators operating power wrenches to secure and release the filter cartridge. The filter cartridge is adapted to make it easy to change a filter element by using a master-slave manipulator at a shielded window station. 6 figs.

  3. Accurate quantification of tio2 nanoparticles collected on air filters using a microwave-assisted acid digestion method

    PubMed Central

    Mudunkotuwa, Imali A.; Anthony, T. Renée; Grassian, Vicki H.; Peters, Thomas M.

    2016-01-01

    Titanium dioxide (TiO2) particles, including nanoparticles with diameters smaller than 100 nm, are used extensively in consumer products. In a 2011 current intelligence bulletin, the National Institute of Occupational Safety and Health (NIOSH) recommended methods to assess worker exposures to fine and ultrafine TiO2 particles and associated occupational exposure limits for these particles. However, there are several challenges and problems encountered with these recommended exposure assessment methods involving the accurate quantitation of titanium dioxide collected on air filters using acid digestion followed by inductively coupled plasma optical emission spectroscopy (ICP-OES). Specifically, recommended digestion methods include the use of chemicals, such as perchloric acid, which are typically unavailable in most accredited industrial hygiene laboratories due to highly corrosive and oxidizing properties. Other alternative methods that are used typically involve the use of nitric acid or combination of nitric acid and sulfuric acid, which yield very poor recoveries for titanium dioxide. Therefore, given the current state of the science, it is clear that a new method is needed for exposure assessment. In this current study, a microwave-assisted acid digestion method has been specifically designed to improve the recovery of titanium in TiO2 nanoparticles for quantitative analysis using ICP-OES. The optimum digestion conditions were determined by changing several variables including the acids used, digestion time, and temperature. Consequently, the optimized digestion temperature of 210°C with concentrated sulfuric and nitric acid (2:1 v/v) resulted in a recovery of >90% for TiO2. The method is expected to provide for a more accurate quantification of airborne TiO2 particles in the workplace environment. PMID:26181824

  4. Accurate quantification of tio2 nanoparticles collected on air filters using a microwave-assisted acid digestion method.

    PubMed

    Mudunkotuwa, Imali A; Anthony, T Renée; Grassian, Vicki H; Peters, Thomas M

    2016-01-01

    Titanium dioxide (TiO(2)) particles, including nanoparticles with diameters smaller than 100 nm, are used extensively in consumer products. In a 2011 current intelligence bulletin, the National Institute of Occupational Safety and Health (NIOSH) recommended methods to assess worker exposures to fine and ultrafine TiO(2) particles and associated occupational exposure limits for these particles. However, there are several challenges and problems encountered with these recommended exposure assessment methods involving the accurate quantitation of titanium dioxide collected on air filters using acid digestion followed by inductively coupled plasma optical emission spectroscopy (ICP-OES). Specifically, recommended digestion methods include the use of chemicals, such as perchloric acid, which are typically unavailable in most accredited industrial hygiene laboratories due to highly corrosive and oxidizing properties. Other alternative methods that are used typically involve the use of nitric acid or combination of nitric acid and sulfuric acid, which yield very poor recoveries for titanium dioxide. Therefore, given the current state of the science, it is clear that a new method is needed for exposure assessment. In this current study, a microwave-assisted acid digestion method has been specifically designed to improve the recovery of titanium in TiO(2) nanoparticles for quantitative analysis using ICP-OES. The optimum digestion conditions were determined by changing several variables including the acids used, digestion time, and temperature. Consequently, the optimized digestion temperature of 210°C with concentrated sulfuric and nitric acid (2:1 v/v) resulted in a recovery of >90% for TiO(2). The method is expected to provide for a more accurate quantification of airborne TiO(2) particles in the workplace environment.

  5. Altered Hepa1-6 cells by dimethyl sulfoxide (DMSO)-treatment induce anti-tumor immunity in vivo.

    PubMed

    Jiang, Zhengyu; Zhang, Hongxia; Wang, Ye; Yu, Bin; Wang, Chen; Liu, Changcheng; Lu, Juan; Chen, Fei; Wang, Minjun; Yu, Xinlu; Lin, Jiahao; Pan, Xinghua; Wang, Pin; Zhu, Haiying

    2016-02-23

    Cancer immunotherapy is the use of the immune system to treat cancer. Our current research proposed an optional strategy of activating immune system involving in cancer immunotherapy. When being treated with 2% DMSO in culture medium, Hepa1-6 cells showed depressed proliferation with no significant apoptosis or decreased viability. D-hep cells, Hepa1-6 cells treated with DMSO for 7 days, could restore to the higher proliferation rate in DMSO-free medium, but alteration of gene expression profile was irreversible. Interestingly, tumors from D-hep cells, not Hepa1-6 cells, regressed in wild-type C57BL/6 mice whereas D-hep cells exhibited similar tumorigenesis as Hep1-6 cells in immunodeficient mice. As expected, additional Hepa1-6 cells failed to form tumors in the D-hep-C57 mice in which D-hep cells were eliminated. Further research confirmed that D-hep-C57 mice established anti-tumor immunity against Hepa1-6 cells. Our research proposed viable tumor cells with altered biological features by DMSO-treatment could induce anti-tumor immunity in vivo.

  6. Behavioral-Physiological Effects of Red Phosphorus Smoke Inhalation on Two Wildlife Species

    DTIC Science & Technology

    1989-04-01

    charcoal bed and a HEPA filter (Mine Safety Appliances Co., Pittsburgh, PA). Next, the humidified, filtered air flowed through PVC tubing to the... filter (American Air Filter , Louisville, KY), a charcoal bed and a HEPA filter (Mine Safety Appliances Co., Pittsburgh, PA). Next, the filtered air flowed...days prior to RP/BR exposure(s). Independent groups of animals (n = 6) then received 1 to 4 successive daily 80-min RP/BR-aerosol or filtered -air

  7. 3-Nitrobenzanthrone and 3-aminobenzanthrone induce DNA damage and cell signalling in Hepa1c1c7 cells.

    PubMed

    Landvik, N E; Arlt, V M; Nagy, E; Solhaug, A; Tekpli, X; Schmeiser, H H; Refsnes, M; Phillips, D H; Lagadic-Gossmann, D; Holme, J A

    2010-02-03

    3-Nitrobenzanthrone (3-NBA) is a mutagenic and carcinogenic environmental pollutant found in diesel exhaust and urban air pollution. In the present work we have characterised the effects of 3-NBA and its metabolite 3-aminobenzanthrone (3-ABA) on cell death and cytokine release in mouse hepatoma Hepa1c1c7 cells. These effects were related to induced DNA damage and changes in cell signalling pathways. 3-NBA resulted in cell death and caused most DNA damage as judged by the amount of DNA adducts ((32)P-postlabelling assay), single strand (ss)DNA breaks and oxidative DNA lesions (comet assay) detected. An increased phosphorylation of H2AX, chk1, chk2 and partly ATM was observed using flow cytometry and/or Western blotting. Both compounds increased phosphorylation of p53 and MAPKs (ERK, p38 and JNK). However, only 3-NBA caused an accumulation of p53 in the nucleus and a translocation of Bax to the mitochondria. The p53 inhibitor pifithrin-alpha inhibited 3-NBA-induced apoptosis, indicating that cell death was a result of the triggering of DNA signalling pathways. The highest phosphorylation of Akt and degradation of IkappaB-alpha (suggesting activation of NF-kappaB) were also seen after treatment with 3-NBA. In contrast 3-ABA increased IL-6 release, but caused little or no toxicity. Cytokine release was inhibited by PD98059 and curcumin, suggesting that ERK and NF-kappaB play a role in this process. In conclusion, 3-NBA seems to have a higher potency to induce DNA damage compatible with its cytotoxic effects, while 3-ABA seems to have a greater effect on the immune system.

  8. Assessment of the Losses Due to Self Absorption by Mass Loading on Radioactive Particulate Air Stack Sample Filters

    SciTech Connect

    Smith, Brian M.; Barnett, J. Matthew; Ballinger, Marcel Y.

    2011-01-18

    This report discusses the effect of mass loading of a membrane filter on the self absorption of radioactive particles. A relationship between mass loading and percent loss of activity is presented. Sample filters were collected from Pacific Northwest National Laboratory (PNNL) facilities in order to analyze the current self absorption correction factor of 0.85 that is being used for both alpha and beta particles. Over an eighteen month period from February 2009 to July 2010, 116 samples were collected and analyzed from eight different building stacks in an effort coordinated by the Effluent Management group. Eleven unused filters were also randomly chosen to be analyzed in order to determine background radiation. All of these samples were collected and analyzed in order to evaluate the current correction factor being used.

  9. 42 CFR 84.1143 - Dust, fume, and mist air-purifying filter tests; performance requirements; general.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide; Paint Spray; Powered Air-Purifying...

  10. 42 CFR 84.1143 - Dust, fume, and mist air-purifying filter tests; performance requirements; general.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide; Paint Spray; Powered Air-Purifying...

  11. 42 CFR 84.1143 - Dust, fume, and mist air-purifying filter tests; performance requirements; general.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide; Paint Spray; Powered Air-Purifying...

  12. 42 CFR 84.1143 - Dust, fume, and mist air-purifying filter tests; performance requirements; general.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide; Paint Spray; Powered Air-Purifying...

  13. Quantitative fuel vapor/air mixing imaging in droplet/gas regions of an evaporating spray flow using filtered Rayleigh scattering.

    PubMed

    Allison, Patton M; McManus, Thomas A; Sutton, Jeffrey A

    2016-03-15

    This Letter demonstrates the application of filtered Rayleigh scattering (FRS) for quantitative two-dimensional fuel vapor/air mixing measurements in an evaporating hydrocarbon fuel spray flow. Using the FRS approach, gas-phase measurements are made in the presence of liquid-phase droplets without interference. Effective suppression of the liquid-phase droplet scattering using FRS is enabled by the high spectral purity of the current Nd:YAG laser system. Simultaneous Mie-scattering imaging is used to visualize the droplet field and illustrate the droplet loading under which the FRS imaging is applied in the current spray flows. The initial quantification of the FRS imaging is based on calibration measurements from a flow cell of known fuel vapor/air mixtures, while future work targets the utilization of a Rayleigh-Brillouin spectral model for quantification of the FRS signals.

  14. Allergies, asthma, and molds

    MedlinePlus

    ... furnace and air conditioner filters often. Use high efficiency particulate air (HEPA) filters to best remove mold from the air. In the bathroom: Use an exhaust fan when you shower or take baths. Use a ...

  15. ATI TDA 5A aerosol generator evaluation

    SciTech Connect

    Gilles, D.A.

    1998-07-27

    Oil based aerosol ``Smoke`` commonly used for testing the efficiency and penetration of High Efficiency Particulate Air filters (HEPA) and HEPA systems can produce flammability hazards that may not have been previously considered. A combustion incident involving an aerosol generator has caused an investigation into the hazards of the aerosol used to test HEPA systems at Hanford.

  16. Interlaboratory evaluation of a standardized inductively coupled plasma mass spectrometry method for the determination of trace beryllium in air filter samples.

    PubMed

    Ashley, Kevin; Brisson, Michael J; Howe, Alan M; Bartley, David L

    2009-12-01

    A collaborative interlaboratory evaluation of a newly standardized inductively coupled plasma mass spectrometry (ICP-MS) method for determining trace beryllium in workplace air samples was carried out toward fulfillment of method validation requirements for ASTM International voluntary consensus standard test methods. The interlaboratory study (ILS) was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Uncertainty was also estimated in accordance with ASTM D7440, which applies the International Organization for Standardization Guide to the Expression of Uncertainty in Measurement to air quality measurements. Performance evaluation materials (PEMs) used consisted of 37 mm diameter mixed cellulose ester filters that were spiked with beryllium at levels of 0.025 (low loading), 0.5 (medium loading), and 10 (high loading) microg Be/filter; these spiked filters were prepared by a contract laboratory. Participating laboratories were recruited from a pool of over 50 invitees; ultimately, 20 laboratories from Europe, North America, and Asia submitted ILS results. Triplicates of each PEM (blanks plus the three different loading levels) were conveyed to each volunteer laboratory, along with a copy of the draft standard test method that each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the PEMs by one of three sample preparation procedures (hotplate or microwave digestion or hotblock extraction) that were described in the draft standard. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS and to report their data in units of mu g Be/filter sample. Interlaboratory precision estimates from participating laboratories, computed in accordance with ASTM E691, were 0.165, 0.108, and 0.151 (relative standard deviation) for the PEMs spiked at 0.025, 0

  17. Use of the HepaRG Cell Line to Assess Potential Human Hepatotoxicity of ToxCast™ Chemicals

    EPA Science Inventory

    The HepaRG cell line is a promising model system for predicting human hepatotoxicity in part because of the greater capacity to metabolize chemicals than other cell models. We hypothesized that this cell line would be a relevant model for toxicity testing of industrial chemicals....

  18. Evaluation of genotoxicity using automated detection of γH2AX in metabolically competent HepaRG cells.

    PubMed

    Quesnot, Nicolas; Rondel, Karine; Audebert, Marc; Martinais, Sophie; Glaise, Denise; Morel, Fabrice; Loyer, Pascal; Robin, Marie-Anne

    2016-01-01

    The in situ detection of γH2AX was recently reported to be a promising biomarker of genotoxicity. In addition, the human HepaRG hepatoma cells appear to be relevant for investigating hepatic genotoxicity since they express most of drug metabolizing enzymes and a wild type p53. The aim of this study was to determine whether the automated in situ detection of γH2AX positive HepaRG cells could be relevant for evaluation of genotoxicity after single or long-term repeated in vitro exposure compared to micronucleus assay. Metabolically competent HepaRG cells were treated daily with environmental contaminants and genotoxicity was evaluated after 1, 7 and 14 days. Using these cells, we confirmed the genotoxicity of aflatoxin B1 and benzo(a)pyrene and demonstrated that dimethylbenzanthracene, fipronil and endosulfan previously found genotoxic with comet or micronucleus assays also induced γH2AX phosphorylation. Furthermore, we showed that fluoranthene and bisphenol A induced γH2AX while no effect had been previously reported in HepG2 cells. In addition, induction of γH2AX was observed with some compounds only after 7 days, highlighting the importance of studying long-term effects of low doses of contaminants. Together, our data demonstrate that automated γH2AX detection in metabolically competent HepaRG cells is a suitable high-through put genotoxicity screening assay.

  19. Beryllium Limits of Detection and Spectral Interferences in 2 Per Cent Nitric Acid, Digested Air Filter Paper, and GHOSTWIPETM Matrices by Inductively Coupled Plasma Emission Spectrometry

    SciTech Connect

    Jurgensen, A.R.

    2004-02-13

    The Analytical Development Section (ADS) of the Savannah River Technology Center (SRTC) has been requested to perform beryllium (Be) analysis on digested Air Filter Paper and GHOSTWIPE (Trade Mark) samples by Inductively Coupled Plasma Emission Spectrometry (ICP-ES). One of the important figures of merit for this analysis is the detection limit (LOD), the smallest concentration of an element that can be detected with a defined certainty. To meet the site Industrial Hygiene (IH) requirements, an instrument LOD of 0.03 mg per Air Filter Paper (1 hr sample) and 0.2 mg per GHOSTWIPE (Trade Mark) must be demonstrated. Another important analytical parameter is the effect on the Be quantization from potential spectral interfering matrix elements. Any existing spectral overlaps could give false positives or increase the measured Be concentrations in these matrices. The purpose of this study was to document the Analytical Development Sections' s contained ICP-ES performance in these two areas. In addition, other Quality Control recommendations will be discussed.

  20. Novel process of bio-chemical ammonia removal from air streams using a water reflux system and zeolite as filter media.

    PubMed

    Vitzthum von Eckstaedt, Sebastian; Charles, Wipa; Ho, Goen; Cord-Ruwisch, Ralf

    2016-02-01

    A novel biofilter that removes ammonia from air streams and converts it to nitrogen gas has been developed and operated continuously for 300 days. The ammonia from the incoming up-flow air stream is first absorbed into water and the carrier material, zeolite. A continuous gravity reflux of condensed water from the exit of the biofilter provides moisture for nitrifying bacteria to develop and convert dissolved ammonia (ammonium) to nitrite/nitrate. The down-flow of the condensed water reflux washes down nitrite/nitrate preventing ammonium and nitrite/nitrate accumulation at the top region of the biofilter. The evaporation caused by the inflow air leads to the accumulation of nitrite to extremely high concentrations in the bottom of the biofilter. The high nitrite concentrations favour the spontaneous chemical oxidation of ammonium by nitrite to nitrogen (N2). Tests showed that this chemical reaction was catalysed by the zeolite filter medium and allowed it to take place at room temperature. This study shows that ammonia can be removed from air streams and converted to N2 in a fully aerated single step biofilter. The process also overcomes the problem of microorganism-inhibition and resulted in zero leachate production.

  1. PPAR agonists reduce steatosis in oleic acid-overloaded HepaRG cells

    SciTech Connect

    Rogue, Alexandra; Anthérieu, Sébastien; Vluggens, Aurore; Umbdenstock, Thierry; Claude, Nancy; Moureyre-Spire, Catherine de la; Weaver, Richard J.; Guillouzo, André

    2014-04-01

    Although non-alcoholic fatty liver disease (NAFLD) is currently the most common form of chronic liver disease there is no pharmacological agent approved for its treatment. Since peroxisome proliferator-activated receptors (PPARs) are closely associated with hepatic lipid metabolism, they seem to play important roles in NAFLD. However, the effects of PPAR agonists on steatosis that is a common pathology associated with NAFLD, remain largely controversial. In this study, the effects of various PPAR agonists, i.e. fenofibrate, bezafibrate, troglitazone, rosiglitazone, muraglitazar and tesaglitazar on oleic acid-induced steatotic HepaRG cells were investigated after a single 24-hour or 2-week repeat treatment. Lipid vesicles stained by Oil-Red O and triglycerides accumulation caused by oleic acid overload, were decreased, by up to 50%, while fatty acid oxidation was induced after 2-week co-treatment with PPAR agonists. The greatest effects on reduction of steatosis were obtained with the dual PPARα/γ agonist muraglitazar. Such improvement of steatosis was associated with up-regulation of genes related to fatty acid oxidation activity and down-regulation of many genes involved in lipogenesis. Moreover, modulation of expression of some nuclear receptor genes, such as FXR, LXRα and CAR, which are potent actors in the control of lipogenesis, was observed and might explain repression of de novo lipogenesis. Conclusion: Altogether, our in vitro data on steatotic HepaRG cells treated with PPAR agonists correlated well with clinical investigations, bringing a proof of concept that drug-induced reversal of steatosis in human can be evaluated in in vitro before conducting long-term and costly in vivo studies in animals and patients. - Highlights: • There is no pharmacological agent approved for the treatment of NAFLD. • This study demonstrates that PPAR agonists can reduce fatty acid-induced steatosis. • Some nuclear receptors appear to be potent actors in the control

  2. Disruption of BSEP Function in HepaRG Cells Alters Bile Acid Disposition and Is a Susceptive Factor to Drug-Induced Cholestatic Injury.

    PubMed

    Qiu, Xi; Zhang, Yueping; Liu, Tongtong; Shen, Hong; Xiao, Yongling; Bourner, Maureen J; Pratt, Jennifer R; Thompson, David C; Marathe, Punit; Humphreys, W Griffith; Lai, Yurong

    2016-04-04

    In the present study, we characterized in vitro biosynthesis and disposition of bile acids (BAs) as well as hepatic transporter expression followed by ABCB11 (BSEP) gene knockout in HepaRG cells (HepaRG-KO cells). BSEP KO in HepaRG cells led to time-dependent BA accumulation, resulting in reduced biosynthesis of BAs and altered BA disposition. In HepaRG-KO cells, the expression of NTCP, OATP1B1, OATP2B1, BCRP, P-gp, and MRP2 were reduced, whereas MRP3 and OCT1 were up-regulated. As a result, BSEP KO altered the disposition of BAs and subsequently underwent adaptive regulations of BA synthesis and homeostasis to enable healthy growth of the cells. Although BSEP inhibitors caused no or slight increase of BAs in HepaRG wild type cells (HepaRG-WT cells), excessive intracellular accumulation of BAs was observed in HepaRG-KO cells exposed to bosentan and troglitazone, but not dipyridamole. LDH release in the medium was remarkably increased in HepaRG-KO cultures exposed to troglitazone (50 μM), suggesting drug-induced cellular injury. The results revealed that functional impairment of BSEP predisposes the cells to altered BA disposition and is a susceptive factor to drug-induced cholestatic injury. In total, BSEP inhibition might trigger the processes but is not a sole determinant of cholestatic cellular injury. As intracellular BA accumulation is determined by BSEP function and the subsequent adaptive gene regulation, assessment of intracellular BA accumulation in HepaRG-KO cells could be a useful approach to evaluate drug-induced liver injury (DILI) potentials of drugs that could disrupt other BA homeostasis pathways beyond BSEP inhibition.

  3. In Vitro Exposures in Diesel Exhaust Atmospheres: Resuspension of PM from Filters Verses Direct Deposition of PM from Air

    PubMed Central

    Lichtveld, Kim M.; Ebersviller, Seth M.; Sexton, Kenneth G.; Vizuete, William; Jaspers, Ilona; Jeffries, Harvey E.

    2012-01-01

    One of the most widely used in vitro particulate matter (PM) exposures methods is the collection of PM on filters, followed by resuspension in a liquid medium, with subsequent addition onto a cell culture. To avoid disruption of equilibria between gases and PM, we have developed a direct in vitro sampling and exposure method (DSEM) capable of PM-only exposures. We hypothesize that the separation of phases and post-treatment of filter-collected PM significantly modifies the toxicity of the PM compared to direct deposition, resulting in a distorted view of the potential PM health effects. Controlled test environments were created in a chamber that combined diesel exhaust with an urban-like mixture. The complex mixture was analyzed using both the DSEM and concurrently-collected filter samples. The DSEM showed that PM from test atmospheres produced significant inflammatory response, while the resuspension exposures at the same exposure concentration did not. Increasing the concentration of resuspended PM sixteen times was required to yield measurable IL-8 expression. Chemical analysis of the resuspended PM indicated a total absence of carbonyl compounds compared to the test atmosphere during the direct-exposures. Therefore, collection and resuspension of PM into liquid modifies its toxicity and likely leads to underestimating toxicity. PMID:22834915

  4. Filter quality of pleated filter cartridges.

    PubMed

    Chen, Chun-Wan; Huang, Sheng-Hsiu; Chiang, Che-Ming; Hsiao, Ta-Chih; Chen, Chih-Chieh

    2008-04-01

    The performance of dust cartridge filters commonly used in dust masks and in room ventilation depends both on the collection efficiency of the filter material and the pressure drop across the filter. Currently, the optimization of filter design is based only on minimizing the pressure drop at a set velocity chosen by the manufacturer. The collection efficiency, an equally important factor, is rarely considered in the optimization process. In this work, a filter quality factor, which combines the collection efficiency and the pressure drop, is used as the optimization criterion for filter evaluation. Most respirator manufacturers pleat the filter to various extents to increase the filtration area in the limit space within the dust cartridge. Six sizes of filter holders were fabricated to hold just one pleat of filter, simulating six different pleat counts, ranging from 0.5 to 3.33 pleats cm(-1). The possible electrostatic charges on the filter were removed by dipping in isopropyl alcohol, and the air velocity is fixed at 100 cm s(-1). Liquid dicotylphthalate particles generated by a constant output atomizer were used as challenge aerosols to minimize particle loading effects. A scanning mobility particle sizer was used to measure the challenge aerosol number concentrations and size distributions upstream and downstream of the pleated filter. The pressure drop across the filter was monitored by using a calibrated pressure transducer. The results showed that the performance of pleated filters depend not only on the size of the particle but also on the pleat count of the pleated filter. Based on filter quality factor, the optimal pleat count (OPC) is always higher than that based on pressure drop by about 0.3-0.5 pleats cm(-1). For example, the OPC is 2.15 pleats cm(-1) from the standpoint of pressure drop, but for the highest filter quality factor, the pleated filter needed to have a pleat count of 2.65 pleats cm(-1) at particle diameter of 122 nm. From the aspect of

  5. Impact of inflammation on chlorpromazine-induced cytotoxicity and cholestatic features in HepaRG cells.

    PubMed

    Bachour-El Azzi, Pamela; Sharanek, Ahmad; Abdel-Razzak, Ziad; Antherieu, Sebastien; Al-Attrache, Houssein; Savary, Camille C; Lepage, Sylvie; Morel, Isabelle; Labbe, Gilles; Guguen-Guillouzo, Christiane; Guillouzo, André

    2014-09-01

    Several factors are thought to be implicated in the occurrence of idiosyncratic adverse drug reactions. The present work aimed to question as to whether inflammation is a determinant factor in hepatic lesions induced by chlorpromazine (CPZ) using the human HepaRG cell line. An inflammation state was induced by a 24-hour exposure to proinflammatory cytokines interleukin-6 (IL-6) and IL-1β; then the cells were simultaneously treated with CPZ and/or cytokine for 24 hours or daily for 5 days. The inflammatory response was assessed by induction of C-reactive protein and IL-8 transcripts and proteins as well as inhibition of CPZ metabolism and down-regulation of cytochrome 3A4 (CYP3A4) and CYP1A2 transcripts, two major cytochrome P450 (P450) enzymes involved in its metabolism. Most effects of cotreatments with cytokines and CPZ were amplified or only observed after five daily treatments; they mainly included increased cytotoxicity and overexpression of oxidative stress-related genes, decreased Na(+)-taurocholate cotransporting polypeptide mRNA levels and activity, a key transporter involved in bile acids uptake, and deregulation of several other transporters. However, CPZ-induced inhibition of taurocholic acid efflux and pericanalicular F-actin distribution were not affected. In addition, a time-dependent induction of phospholipidosis was noticed in CPZ-treated cells, without obvious influence of the inflammatory stress. In summary, our results show that an inflammatory state induced by proinflammatory cytokines increased cytotoxicity and enhanced some cholestatic features induced by the idiosyncratic drug CPZ in HepaRG cells. These changes, together with inhibition of P450 activities, could have important consequences if extrapolated to the in vivo situation.

  6. Hepatitis B vaccine induces apoptotic death in Hepa1-6 cells.

    PubMed

    Hamza, Heyam; Cao, Jianhua; Li, Xinyun; Li, Changchun; Zhu, Mengjin; Zhao, Shuhong

    2012-05-01

    Vaccines can have adverse side-effects, and these are predominantly associated with the inclusion of chemical additives such as aluminum hydroxide adjuvant. The objective of this study was to establish an in vitro model system amenable to mechanistic investigations of cytotoxicity induced by hepatitis B vaccine, and to investigate the mechanisms of vaccine-induced cell death. The mouse liver hepatoma cell line Hepa1-6 was treated with two doses of adjuvanted (aluminium hydroxide) hepatitis B vaccine (0.5 and 1 μg protein per ml) and cell integrity was measured after 24, 48 and 72 h. Hepatitis B vaccine exposure increased cell apoptosis as detected by flow cytometry and TUNEL assay. Vaccine exposure was accompanied by significant increases in the levels of activated caspase 3, a key effector caspase in the apoptosis cascade. Early transcriptional events were detected by qRT-PCR. We report that hepatitis B vaccine exposure resulted in significant upregulation of the key genes encoding caspase 7, caspase 9, Inhibitor caspase-activated DNase (ICAD), Rho-associated coiled-coil containing protein kinase 1 (ROCK-1), and Apoptotic protease activating factor 1 (Apaf-1). Upregulation of cleaved caspase 3,7 were detected by western blot in addition to Apaf-1 and caspase 9 expressions argues that cell death takes place via the intrinsic apoptotic pathway in which release of cytochrome c from the mitochondria triggers the assembly of a caspase activation complex. We conclude that exposure of Hepa1-6 cells to a low dose of adjuvanted hepatitis B vaccine leads to loss of mitochondrial integrity, apoptosis induction, and cell death, apoptosis effect was observed also in C2C12 mouse myoblast cell line after treated with low dose of vaccine (0.3, 0.1, 0.05 μg/ml). In addition In vivo apoptotic effect of hepatitis B vaccine was observed in mouse liver.

  7. Early detection of foot-and-mouth disease virus from infected cattle using a dry filter air sampling system

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Foot-and-mouth disease (FMD) is a highly contagious livestock disease of high economic impact. Early detection of FMD virus (FMDV) is fundamental for rapid outbreak control. Air sampling collection has been demonstrated as a useful technique for detection of FMDV RNA in infected animals, related to ...

  8. Comparison of continuous air monitor utilization: A case study

    SciTech Connect

    Rodgers, J.C.; Whicker, J.J.; Voss, J.T.

    1997-08-01

    The Chemical Metallurgy Research (CMR) building has been upgrading to different continuous air monitors (CAMs) over the past several years. During the transition, both the newer and older CAMs were positioned in the rooms for field testing and comparison. On December 19, 1996, an accidental release of plutonium aerosol occurred into a laboratory in the CMR building. The event occurred while the room was unoccupied, and no personnel were exposed from this incident. There were two fixed air samplers (FASs) and three CAMs operating in the room at the time the release occurred, including two of the recently installed Canberra Alpha Sentry CAMs and one older Eberline CAM. The apparent cause of the release was a procedure carried out in the basement involving the replacement of the HEPA filter in the ventilation exhaust of a slot-box in the laboratory. For a short period, the ventilation was disconnected from the slot-box in this room, but not from the chemical hood exhaust on the opposite side of the laboratory. Therefore, a condition was created where backflow could occur out of the slot-box and into the room. Eventually all three CAMs in the room alarmed, and the situation was successfully monitored and brought under control by health physics personnel. Data on CAM performance were logged, and Pu activity collected on CAM and FAS filters were measured. A comparison of the new and old continuous air monitoring programs was performed and many interesting lessons on CAM performance and CAM utilization were learned. Overall, this comparison showed the advantages of remote monitoring, timely spectral information, and concentration measurements resolved in time and space.

  9. Compact interrogator for fiber optic Bragg sensors based on an acousto-optic filter formed by photonic crystal rows of air holes.

    PubMed

    Tsarev, Andrei V; De Leonardis, Francesco; Passaro, Vittorio M N

    2011-10-01

    Fiber optic sensors are typically used with expensive tunable lasers or optical spectrum analyzers for wavelength interrogation. We propose to replace the tunable laser by a broadband optical source incorporated with a novel thin linewidth acousto-optic tunable filter. It utilizes optical beam expanders constituted by photonic crystal rows of air holes in LiNbO(3) waveguide. A new design is numerically studied for a short structure (with 32 photonic crystal rows) by a two-dimensional finite-difference time-domain method. Extrapolation of these results to larger structure sizes (about 1 cm) demonstrates the possibility to develop compact interrogators with 0.4 pm wavelength resolution and 40 nm tunable range around 1550 nm.

  10. Assessing the Impact of Water Filters and Improved Cook Stoves on Drinking Water Quality and Household Air Pollution: A Randomised Controlled Trial in Rwanda

    PubMed Central

    Rosa, Ghislaine; Majorin, Fiona; Boisson, Sophie; Barstow, Christina; Johnson, Michael; Kirby, Miles; Ngabo, Fidele; Thomas, Evan; Clasen, Thomas

    2014-01-01

    Diarrhoea and respiratory infections remain the biggest killers of children under 5 years in developing countries. We conducted a 5-month household randomised controlled trial among 566 households in rural Rwanda to assess uptake, compliance and impact on environmental exposures of a combined intervention delivering high-performance water filters and improved stoves for free. Compliance was measured monthly by self-report and spot-check observations. Semi-continuous 24-h PM2.5 monitoring of the cooking area was conducted in a random subsample of 121 households to assess household air pollution, while samples of drinking water from all households were collected monthly to assess the levels of thermotolerant coliforms. Adoption was generally high, with most householders reporting the filters as their primary source of drinking water and the intervention stoves as their primary cooking stove. However, some householders continued to drink untreated water and most continued to cook on traditional stoves. The intervention was associated with a 97.5% reduction in mean faecal indicator bacteria (Williams means 0.5 vs. 20.2 TTC/100 mL, p<0.001) and a median reduction of 48% of 24-h PM2.5 concentrations in the cooking area (p = 0.005). Further studies to increase compliance should be undertaken to better inform large-scale interventions. Trial registration: Clinicaltrials.gov; NCT01882777; http://clinicaltrials.gov/ct2/results?term=NCT01882777&Search=Search PMID:24614750

  11. The performance of a two-layer biotrickling filter filled with new mixed packing materials for the removal of H2S from air.

    PubMed

    Chen, Yingwen; Wang, Xiaojun; He, Shuo; Zhu, Shemin; Shen, Shubao

    2016-01-01

    In the work described here, a two-layer biotrickling filter filled with new packing materials was used to remove H2S from air. The upper layer of the filter was packed with activated carbon-loaded polyurethane, whereas the lower layer was filled with modified organism-suspended fillers. The effects of inlet load, empty bed residence time (EBRT) from 79 s to 53 s, pH and contaminant starvation time were investigated. For loads of 15-50 g/(m(3) h), the average removal efficiency (RE) was higher than 96% under a consistent supply of pollutants. The critical elimination capacity was 39.95 g/(m(3) h) for an EBRT of 53 s with an RE of 99.9%. The two-layer BTF was capable of withstanding contaminant starvation periods for 1.5 d and 7 d with only a few hours of recovery time. The biodegradation kinetics was studied using Michaelis-Menten type equations under different EBRTs. At an EBRT of 66 s, the optimal kinetic constants rmax and Km were 333.3 g/(m(3) h) and 0.93 g/m(3), respectively. During the operation, the two-layer BTF performed well under various reasonable conditions.

  12. Concentrations of polybrominated diphenyl ethers (PBDEs) in central air-conditioner filter dust and relevance of non-dietary exposure in occupational indoor environments in Greece.

    PubMed

    Besis, Athanasios; Katsoyiannis, Athanasios; Botsaropoulou, Elisavet; Samara, Constantini

    2014-05-01

    Polybrominated Diphenyl Ethers (PBDEs) are ubiquitous in the indoor environment owing to their use in consumer products and various studies around the world have found higher concentrations indoors than outdoors. Central air conditioner (A/C) systems have been widely used in many workplaces, therefore, studying of PBDEs in central A/C filter dust is useful to better understand the occurrences and health implications of PBDEs in indoor environments. The present study examined the occurrence of PBDEs in central A/C filter dust collected from various workplaces (n = 20) in Thessaloniki, Greece. The sum concentrations of 21 target congeners (∑21PBDE) in A/C dust ranged between 84 and 4062 ng g(-1) with a median value of 1092 ng g(-1), while BDE-209 was found to be the most abundant BDE congener. The daily intake via dust ingestion of PBDEs estimated for the employees of the occupational settings ranged from 3 to 45 ng day(-1) (median 12 ng day(-1)).

  13. A comparison of whole genome gene expression profiles of HepaRG cells and HepG2 cells to primary human hepatocytes and human liver tissues.

    PubMed

    Hart, Steven N; Li, Ye; Nakamoto, Kaori; Subileau, Eva-anne; Steen, David; Zhong, Xiao-bo

    2010-06-01

    HepaRG cells, derived from a female hepatocarcinoma patient, are capable of differentiating into biliary epithelial cells and hepatocytes. More importantly, differentiated HepaRG cells are able to maintain activities of many xenobiotic-metabolizing enzymes, and expression of the metabolizing enzyme genes can be induced by xenobiotics. The ability of these cells to express and induce xenobiotic-metabolizing enzymes is in stark contrast to the frequently used HepG2 cells. The previous studies have mainly focused on a set of selected genes; therefore, it is of significant interest to know the extent of similarity of gene expression at whole genome levels in HepaRG cells and HepG2 cells compared with primary human hepatocytes and human liver tissues. To accomplish this objective, we used Affymetrix (Santa Clara, CA) U133 Plus 2.0 arrays to characterize the whole genome gene expression profiles in triplicate biological samples from HepG2 cells, HepaRG cells (undifferentiated and differentiated cells), freshly isolated primary human hepatocytes, and frozen liver tissues. After using similarity matrix, principal components, and hierarchical clustering methods, we found that HepaRG cells globally transcribe genes at levels more similar to human primary hepatocytes and human liver tissues than HepG2 cells. In particular, many genes encoding drug-processing proteins are transcribed at a more similar level in HepaRG cells than in HepG2 cells compared with primary human hepatocytes and liver samples. The transcriptomic similarity of HepaRG with primary human hepatocytes is encouraging for use of HepaRG cells in the study of xenobiotic metabolism, hepatotoxicology, and hepatocyte differentiation.

  14. Acceptable knowledge summary report for combustible/noncombustible, metallic, and HEPA filter waste resulting from {sup 238}Pu fabrication activities

    SciTech Connect

    Rogers, P.S.Z.; Foxx, C.L.

    1998-02-19

    All transuranic (TRU) waste must be sufficiently characterized and certified before it is shipped to the Waste Isolation Pilot Plant (WIPP). The US Environmental Protection Agency (EPA) allows use of acceptable knowledge (AK) for waste characterization. EPA uses the term AK in its guidance document and defines AK and provides guidelines on how acceptable knowledge should be obtained and documented. This AK package has been prepared in accordance with Acceptable Knowledge Documentation (TWCP-QP-1.1-021,R.2). This report covers acceptable knowledge information for five waste streams generated at TA-55 during operations to fabricate various heat sources using feedstock {sup 238}Pu supplied by the Savannah River Site (SRS). The {sup 238}Pu feedstock itself does not contain quantities of RCRA-regulated constituents above regulatory threshold limits, as known from process knowledge at SRS and as confirmed by chemical analysis. No RCRA-regulated chemicals were used during {sup 238}Pu fabrication activities at TA-55, and all {sup 238}Pu activities were physically separated from other plutonium processing activities. Most of the waste generated from the {sup 238}Pu fabrication activities is thus nonmixed waste, including waste streams TA-55-43, 45, and 47. The exceptions are waste streams TA-55-44, which contains discarded lead-lined rubber gloves used in the gloveboxes that contained the {sup 238}Pu material, and TA-55-46, which may contain pieces of discarded lead. These waste streams have been denoted as mixed because of the presence of the lead-containing material.

  15. Comparative Localization and Functional Activity of the Main Hepatobiliary Transporters in HepaRG Cells and Primary Human Hepatocytes

    PubMed Central

    Bachour-El Azzi, Pamela; Sharanek, Ahmad; Burban, Audrey; Li, Ruoya; Guével, Rémy Le; Abdel-Razzak, Ziad; Stieger, Bruno; Guguen-Guillouzo, Christiane; Guillouzo, André

    2015-01-01

    The role of hepatobiliary transporters in drug-induced liver injury remains poorly understood. Various in vivo and in vitro biological approaches are currently used for studying hepatic transporters; however, appropriate localization and functional activity of these transporters are essential for normal biliary flow and drug transport. Human hepatocytes (HHs) are considered as the most suitable in vitro cell model but erratic availability and inter-donor functional variations limit their use. In this work, we aimed to compare localization of influx and efflux transporters and their functional activity in differentiated human HepaRG hepatocytes with fresh HHs in conventional (CCHH) and sandwich (SCHH) cultures. All tested influx and efflux transporters were correctly localized to canalicular [bile salt export pump (BSEP), multidrug resistance-associated protein 2 (MRP2), multidrug resistance protein 1 (MDR1), and MDR3] or basolateral [Na+-taurocholate co-transporting polypeptide (NTCP) and MRP3] membrane domains and were functional in all models. Contrary to other transporters, NTCP and BSEP were less abundant and active in HepaRG cells, cellular uptake of taurocholate was 2.2- and 1.4-fold and bile excretion index 2.8- and 2.6-fold lower, than in SCHHs and CCHHs, respectively. However, when taurocholate canalicular efflux was evaluated in standard and divalent cation-free conditions in buffers or cell lysates, the difference between the three models did not exceed 9.3%. Interestingly, cell imaging showed higher bile canaliculi contraction/relaxation activity in HepaRG hepatocytes and larger bile canaliculi networks in SCHHs. Altogether, our results bring new insights in mechanisms involved in bile acids accumulation and excretion in HHs and suggest that HepaRG cells represent a suitable model for studying hepatobiliary transporters and drug-induced cholestasis. PMID:25690737

  16. Expression of cytochromes P450, conjugating enzymes and nuclear receptors in human hepatoma HepaRG cells.

    PubMed

    Aninat, Caroline; Piton, Amélie; Glaise, Denise; Le Charpentier, Typhen; Langouët, Sophie; Morel, Fabrice; Guguen-Guillouzo, Christiane; Guillouzo, André

    2006-01-01

    Most human hepatocyte cell lines lack a substantial set of liver-specific functions, especially major cytochrome P450 (P450)-related enzyme activities, making them unrepresentative of in vivo hepatocytes. We have used the HepaRG cells, derived from a human hepatocellular carcinoma, which exhibit a high differentiation pattern after 2 weeks at confluency to determine whether they could mimic human hepatocytes for drug metabolism and toxicity studies. We show that when passaged at low density, these cells reversed to an undifferentiated morphology, actively divided, and, after having reached confluency, formed typical hepatocyte-like colonies surrounded by biliary epithelial-like cells. By contrast, when seeded at high density, hepatocyte-like clusters retained their typical differentiated morphology. Transcripts of various nuclear receptors (aryl hydrocarbon receptor, pregnane X receptor, constitutive androstane receptor, peroxisome proliferator-activated receptor alpha), P450s (CYP1A2, 2C9, 2D6, 2E1, 3A4), phase 2 enzymes (UGT1A1, GSTA1, GSTA4, GSTM1), and other liver-specific functions were estimated by reverse transcriptase-quantitative polymerase chain reaction and were found to be expressed, for most of them, at comparable levels in both confluent differentiated and high-density differentiated HepaRG cells and in cultured primary human hepatocytes. For several transcripts, the levels were strongly increased in the presence of 2% dimethyl sulfoxide. Measurement of basal activities of several P450s and their response to prototypical inducers as well as analysis of metabolic profiles and cytotoxicity of several compounds confirmed the functional resemblance of HepaRG cells to primary cultured human hepatocytes. In conclusion, HepaRG cells constitute the first human hepatoma cell line expressing high levels of the major P450s involved in xenobiotic metabolism and represent a reliable surrogate to human hepatocytes for drug metabolism and toxicity studies.

  17. First retrieval of hourly atmospheric radionuclides just after the Fukushima accident by analyzing filter-tapes of operational air pollution monitoring stations

    PubMed Central

    Tsuruta, Haruo; Oura, Yasuji; Ebihara, Mitsuru; Ohara, Toshimasa; Nakajima, Teruyuki

    2014-01-01

    No observed data have been found in the Fukushima Prefecture (FP) for the time-series of atmospheric radionuclides concentrations just after the Fukushima Daiichi Nuclear Power Plant (FD1NPP) accident. Accordingly, current estimates of internal radiation doses from inhalation, and atmospheric radionuclide concentrations by atmospheric transport models are highly uncertain. Here, we present a new method for retrieving the hourly atmospheric 137Cs concentrations by measuring the radioactivity of suspended particulate matter (SPM) collected on filter tapes in SPM monitors which were operated even after the accident. This new dataset focused on the period of March 12–23, 2011 just after the accident, when massive radioactive materials were released from the FD1NPP to the atmosphere. Overall, 40 sites of the more than 400 sites in the air quality monitoring stations in eastern Japan were studied. For the first time, we show the spatio-temporal variation of atmospheric 137Cs concentrations in the FP and the Tokyo Metropolitan Area (TMA) located more than 170 km southwest of the FD1NPP. The comprehensive dataset revealed how the polluted air masses were transported to the FP and TMA, and can be used to re-evaluate internal exposure, time-series radionuclides release rates, and atmospheric transport models. PMID:25335435

  18. First retrieval of hourly atmospheric radionuclides just after the Fukushima accident by analyzing filter-tapes of operational air pollution monitoring stations.

    PubMed

    Tsuruta, Haruo; Oura, Yasuji; Ebihara, Mitsuru; Ohara, Toshimasa; Nakajima, Teruyuki

    2014-10-22

    No observed data have been found in the Fukushima Prefecture (FP) for the time-series of atmospheric radionuclides concentrations just after the Fukushima Daiichi Nuclear Power Plant (FD1NPP) accident. Accordingly, current estimates of internal radiation doses from inhalation, and atmospheric radionuclide concentrations by atmospheric transport models are highly uncertain. Here, we present a new method for retrieving the hourly atmospheric (137)Cs concentrations by measuring the radioactivity of suspended particulate matter (SPM) collected on filter tapes in SPM monitors which were operated even after the accident. This new dataset focused on the period of March 12-23, 2011 just after the accident, when massive radioactive materials were released from the FD1NPP to the atmosphere. Overall, 40 sites of the more than 400 sites in the air quality monitoring stations in eastern Japan were studied. For the first time, we show the spatio-temporal variation of atmospheric (137)Cs concentrations in the FP and the Tokyo Metropolitan Area (TMA) located more than 170 km southwest of the FD1NPP. The comprehensive dataset revealed how the polluted air masses were transported to the FP and TMA, and can be used to re-evaluate internal exposure, time-series radionuclides release rates, and atmospheric transport models.

  19. Air annealing effects on the optical properties of ZnO SnO2 thin films deposited by a filtered vacuum arc deposition system

    NASA Astrophysics Data System (ADS)

    Çetinörgü, E.; Goldsmith, S.; Boxman, R. L.

    2006-03-01

    ZnO-SnO2 transparent and conducting thin films were deposited on microscope glass substrates by a filtered vacuum arc deposition (FVAD) system. The cathode was prepared with 50%:50% atomic concentration of Zn:Sn. The films were annealed in air at 500 °C for 1 h. Structural and compositional analyses were obtained using XRD and XPS diagnostics. X-ray diffraction analysis indicated that as-deposited and air-annealed thin ZnO-SnO2 films were amorphous. The atomic ratio of Zn to Sn in the film obtained using the 50%:50% cathode as determined by XPS analysis was ~2.7:1 in the bulk film. The optical properties were determined from normal incidence transmission measurements. Film transmission in the visible was 70% to 90%, affected by interference effects. Annealed films did not show higher transmission in the VIS compared to as-deposited films. Assuming that the interband electron transition is direct, the optical band gap was found to be in the range 3.34-3.61 eV for both as-deposited and annealed films. However, the average Eg for annealed films was 3.6 eV, larger by 0.2 eV than that of as-deposited. The refractive index n increased while the extinction index k decreased significantly with annealing.

  20. A NEW NON-DESTRUCTIVE METHOD FOR CHEMICAL ANALYSIS OF PARTICULATE MATTER FILTERS: THE CASE OF MANGANESE AIR POLLUTION IN VALLECAMONICA (ITALY)

    PubMed Central

    Borgese, Laura; Zacco, Annalisa; Pal, Sudipto; Bontempi, Elza; Lucchini, Roberto; Zimmerman, Neil; Depero, Laura E.

    2011-01-01

    Total Reflection X-ray Fluorescence (TXRF) is a well-established technique for chemical analysis, but it is mainly employed for quality control in the electronics semiconductor industry. The capability to analyze liquid and uniformly thin solid samples makes this technique suitable for other applications, and especially in the very critical field of environmental analysis. Comparison with standard methods like Inductively Coupled Plasma (ICP) and Atomic Absorption Spectroscopy (AAS) show that TXRF is a practical, accurate, and reliable technique in occupational settings. Due to the greater sensitivity necessary in trace heavy metal detection, TXRF is also suitable for environmental chemical analysis. In this paper we show that based on appropriate standards, TXRF can be considered for non-destructive routine quantitative analysis of environmental matrices such as air filters. This work has been developed in the frame of the EU-FP6 PHIME (Public Health Impact of long-term, low-level Mixed element Exposure in susceptible population strata) Integrated Project (www.phime.org). The aim of this work was to investigate Mn air pollution in the area of Vallecamonica (Italy). PMID:21315919

  1. Impacts of using an ensemble Kalman filter on air quality simulations along the California-Mexico border region during Cal-Mex 2010 field campaign.

    PubMed

    Bei, Naifang; Li, Guohui; Meng, Zhiyong; Weng, Yonghui; Zavala, Miguel; Molina, L T

    2014-11-15

    The purpose of this study is to investigate the impact of using an ensemble Kalman filter (EnKF) on air quality simulations in the California-Mexico border region on two days (May 30 and June 04, 2010) during Cal-Mex 2010. The uncertainties in ozone (O3) and aerosol simulations in the border area due to the meteorological initial uncertainties were examined through ensemble simulations. The ensemble spread of surface O3 averaged over the coastal region was less than 10ppb. The spreads in the nitrate and ammonium aerosols are substantial on both days, mostly caused by the large uncertainties in the surface temperature and humidity simulations. In general, the forecast initialized with the EnKF analysis (EnKF) improved the simulation of meteorological fields to some degree in the border region compared to the reference forecast initialized with NCEP analysis data (FCST) and the simulation with observation nudging (FDDA), which in turn leading to reasonable air quality simulations. The simulated surface O3 distributions by EnKF were consistently better than FCST and FDDA on both days. EnKF usually produced more reasonable simulations of nitrate and ammonium aerosols compared to the observations, but still have difficulties in improving the simulations of organic and sulfate aerosols. However, discrepancies between the EnKF simulations and the measurements were still considerably large, particularly for sulfate and organic aerosols, indicating that there are still ample rooms for improvement in the present data assimilation and/or the modeling systems.

  2. 40 CFR 721.10002 - 2-Thiazolidinone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... respirator equipped with a loose-fitting hood or helmet and High Efficiency Particulate Air (HEPA) filters... HEPA filters; and supplied-air respirator operated in pressure demand or continuous flow mode and... substance may cause internal organ effects (blood, liver, and kidney). The substance may cause...

  3. SU-E-T-339: Dosimetric Verification of Acuros XB Dose Calculation Algorithm On An Air Cavity for 6-MV Flattening Filter-Free Beam

    SciTech Connect

    Kang, S; Suh, T; Chung, J

    2015-06-15

    Purpose: This study was to verify the accuracy of Acuros XB (AXB) dose calculation algorithm on an air cavity for a single radiation field using 6-MV flattening filter-free (FFF) beam. Methods: A rectangular slab phantom containing an air cavity was made for this study. The CT images of the phantom for dose calculation were scanned with and without film at measurement depths (4.5, 5.5, 6.5 and 7.5 cm). The central axis doses (CADs) and the off-axis doses (OADs) were measured by film and calculated with Analytical Anisotropic Algorithm (AAA) and AXB for field sizes ranging from 2 Χ 2 to 5 Χ 5 cm{sup 2} of 6-MV FFF beams. Both algorithms were divided into AXB-w and AAA -w when included the film in phantom for dose calculation, and AXB-w/o and AAA-w/o in calculation without film. The calculated OADs for both algorithms were compared with the measured OADs and difference values were determined using root means squares error (RMSE) and gamma evaluation. Results: The percentage differences (%Diffs) between the measured and calculated CAD for AXB-w was most agreement than others. Compared to the %Diff with and without film, the %Diffs with film were decreased than without within both algorithms. The %Diffs for both algorithms were reduced with increasing field size and increased relative to the depth increment. RMSEs of CAD for AXB-w were within 10.32% for both inner-profile and penumbra, while the corresponding values of AAA-w appeared to 96.50%. Conclusion: This study demonstrated that the dose calculation with AXB within air cavity shows more accurate than with AAA compared to the measured dose. Furthermore, we found that the AXB-w was superior to AXB-w/o in this region when compared against the measurements.

  4. Levels of 25 trace elements in high-volume air filter samples from Seville (2001-2002): Sources, enrichment factors and temporal variations

    NASA Astrophysics Data System (ADS)

    Enamorado-Báez, S. M.; Gómez-Guzmán, J. M.; Chamizo, E.; Abril, J. M.

    2015-03-01

    The measurement of trace element concentration in aerosols is of interest for environmental studies and for human health assessment. The temporal variability of total suspended particles (TSP) and its elemental composition in Seville, in SW Spain, is of particular complexity since Atlantic air masses and Saharan Dust Intrusions (SDI) overlap to local natural and anthropogenic sources. This paper is aimed to study the temporal evolution (in a monthly basis) of the concentrations of 25 trace elements, determined by ICP-MS, in high-volume air filter samples from Seville, covering a two-year period: 2001-2002. The mean TSP value for this period was 79.7 μg m- 3 and showed peak values in August 2001 and June 2002, likely related to SDI. Enrichment factors (EF) for Se, Sb and Zn and Pb were above 100, which revealed their anthropogenic sources. The comparison among EF from Seville and Huelva, a highly industrialized city nearby Seville, showed higher levels of anthropogenic elements there than in Seville. Simulations of the transport/dispersion of pollutants starting in Huelva confirm that air pollutants can reach Seville in the course of around 6 hours although they do not contribute significantly to the levels found in this city. A significant temporal correlation was found between elements which have a common source, being crustal (Al, Ti, Be, Co, Cs, Fe, Cr, Mn, U, Sr and Th) or anthropogenic sources (Zn, Pb, Cd). The temporal variations of those crustal elements are similar and related with the TSP levels for both years, with the clearly visible peaks probably related with the Saharan dust intrusion.

  5. Optimization of the performance of a thermophilic biotrickling filter for alpha-pinene removal from polluted air.

    PubMed

    Montes, M; Veiga, M C; Kennes, C

    2014-01-01

    Biodegradation of alpha-pinene was investigated in a biological thermophilic trickling filter, using a lava rock and polymer beads mixture as packing material. Partition coefficient (PC) between alpha-pinene and the polymeric material (Hytrel G3548 L) was measured at 50 degrees C. PCs of 57 and 846 were obtained between the polymer and either the water or the gas phase, respectively. BTF experiments were conducted under continuous load feeding. The effect of yeast extract (YE) addition in the recirculating nutrient medium was evaluated. There was a positive relationship between alpha-pinene biodegradation, CO2 production and YE addition. A maximum elimination capacity (ECmax) of 98.9 g m(-3) h(-1) was obtained for an alpha-pinene loading rate of about 121 g m(-3) h(-1) in the presence of 1 g L(-1) YE. The ECmax was reduced by half in the absence of YE. It was also found that a decrease in the liquid flow rate enhances alpha-pinene biodegradation by increasing the ECmax up to 103 gm(-3) h(-1) with a removal efficiency close to 90%. The impact of short-term shock-loads (6 h) was tested under different process conditions. Increasing the pollutant load either 10- or 20-fold resulted in a sudden drop in the BTF's removal capacity, although this effect was attenuated in the presence of YE.

  6. Evaluating the Long-Term Health and Economic Impacts of Central Residential Air Filtration for Reducing Premature Mortality Associated with Indoor Fine Particulate Matter (PM2.5) of Outdoor Origin.

    PubMed

    Zhao, Dan; Azimi, Parham; Stephens, Brent

    2015-07-21

    Much of human exposure to fine particulate matter (PM2.5) of outdoor origin occurs in residences. High-efficiency particle air filtration in central heating, ventilating, and air-conditioning (HVAC) systems is increasingly being used to reduce concentrations of particulate matter inside homes. However, questions remain about the effectiveness of filtration for reducing exposures to PM2.5 of outdoor origin and adverse health outcomes. Here we integrate epidemiology functions and mass balance modeling to estimate the long-term health and economic impacts of HVAC filtration for reducing premature mortality associated with indoor PM2.5 of outdoor origin in residences. We evaluate 11 classifications of filters (MERV 5 through HEPA) using six case studies of single-family home vintages and ventilation system combinations located in 22 U.S. cities. We estimate that widespread use of higher efficiency filters would reduce premature mortality by 0.002-2.5% and increase life expectancy by 0.02-1.6 months, yielding annual monetary benefits ranging from $1 to $1348 per person in the homes and locations modeled herein. Large differences in the magnitude of health and economic impacts are driven largely by differences in rated filter efficiency and building and ventilation system characteristics that govern particle infiltration and persistence, with smaller influences attributable to geographic location.

  7. Evaluating the Long-Term Health and Economic Impacts of Central Residential Air Filtration for Reducing Premature Mortality Associated with Indoor Fine Particulate Matter (PM2.5) of Outdoor Origin

    PubMed Central

    Zhao, Dan; Azimi, Parham; Stephens, Brent

    2015-01-01

    Much of human exposure to fine particulate matter (PM2.5) of outdoor origin occurs in residences. High-efficiency particle air filtration in central heating, ventilating, and air-conditioning (HVAC) systems is increasingly being used to reduce concentrations of particulate matter inside homes. However, questions remain about the effectiveness of filtration for reducing exposures to PM2.5 of outdoor origin and adverse health outcomes. Here we integrate epidemiology functions and mass balance modeling to estimate the long-term health and economic impacts of HVAC filtration for reducing premature mortality associated with indoor PM2.5 of outdoor origin in residences. We evaluate 11 classifications of filters (MERV 5 through HEPA) using six case studies of single-family home vintages and ventilation system combinations located in 22 U.S. cities. We estimate that widespread use of higher efficiency filters would reduce premature mortality by 0.002–2.5% and increase life expectancy by 0.02–1.6 months, yielding annual monetary benefits ranging from $1 to $1348 per person in the homes and locations modeled herein. Large differences in the magnitude of health and economic impacts are driven largely by differences in rated filter efficiency and building and ventilation system characteristics that govern particle infiltration and persistence, with smaller influences attributable to geographic location. PMID:26197328

  8. The histone deacetylase inhibiting drug Entinostat induces lipid accumulation in differentiated HepaRG cells

    PubMed Central

    Nunn, Abigail D. G.; Scopigno, Tullio; Pediconi, Natalia; Levrero, Massimo; Hagman, Henning; Kiskis, Juris; Enejder, Annika

    2016-01-01

    Dietary overload of toxic, free metabolic intermediates leads to disrupted insulin signalling and fatty liver disease. However, it was recently reported that this pathway might not be universal: depletion of histone deacetylase (HDAC) enhances insulin sensitivity alongside hepatic lipid accumulation in mice, but the mechanistic role of microscopic lipid structure in this effect remains unclear. Here we study the effect of Entinostat, a synthetic HDAC inhibitor undergoing clinical trials, on hepatic lipid metabolism in the paradigmatic HepaRG liver cell line. Specifically, we statistically quantify lipid droplet morphology at single cell level utilizing label-free microscopy, coherent anti-Stokes Raman scattering, supported by gene expression. We observe Entinostat efficiently rerouting carbohydrates and free-fatty acids into lipid droplets, upregulating lipid coat protein gene Plin4, and relocating droplets nearer to the nucleus. Our results demonstrate the power of Entinostat to promote lipid synthesis and storage, allowing reduced systemic sugar levels and sequestration of toxic metabolites within protected protein-coated droplets, suggesting a potential therapeutic strategy for diseases such as diabetes and metabolic syndrome. PMID:27320682

  9. The histone deacetylase inhibiting drug Entinostat induces lipid accumulation in differentiated HepaRG cells

    NASA Astrophysics Data System (ADS)

    Nunn, Abigail D. G.; Scopigno, Tullio; Pediconi, Natalia; Levrero, Massimo; Hagman, Henning; Kiskis, Juris; Enejder, Annika

    2016-06-01

    Dietary overload of toxic, free metabolic intermediates leads to disrupted insulin signalling and fatty liver disease. However, it was recently reported that this pathway might not be universal: depletion of histone deacetylase (HDAC) enhances insulin sensitivity alongside hepatic lipid accumulation in mice, but the mechanistic role of microscopic lipid structure in this effect remains unclear. Here we study the effect of Entinostat, a synthetic HDAC inhibitor undergoing clinical trials, on hepatic lipid metabolism in the paradigmatic HepaRG liver cell line. Specifically, we statistically quantify lipid droplet morphology at single cell level utilizing label-free microscopy, coherent anti-Stokes Raman scattering, supported by gene expression. We observe Entinostat efficiently rerouting carbohydrates and free-fatty acids into lipid droplets, upregulating lipid coat protein gene Plin4, and relocating droplets nearer to the nucleus. Our results demonstrate the power of Entinostat to promote lipid synthesis and storage, allowing reduced systemic sugar levels and sequestration of toxic metabolites within protected protein-coated droplets, suggesting a potential therapeutic strategy for diseases such as diabetes and metabolic syndrome.

  10. An Improved Method to Determine {sup 210}Pb, {sup 210}Bi and {sup 210}Po in air Aerosol Filters

    SciTech Connect

    Miguel, E. G. San; Bolivar, J. P.; Teran, T.

    2008-08-07

    {sup 222}Rn daughters (e.g. {sup 210}Pb, {sup 210}Po, {sup 210}Bi) have been widely used to study a variety of atmospheric processes. Many works in literature about {sup 222}Rn daughters do not specify the way by the activities of these radionuclides are calculated. Besides, {sup 210}Po corrections due to the in-growth of {sup 210}Bi, if taken into account, are not indicated. In this work, the increase in uncertainties of radionuclides activities due to delay between air sampling and radionuclides determinations have been evaluated and the influence of neglecting the contribution of {sup 210}Bi in-growth to {sup 210}Po determination has been estimated. The results indicate that, in general, ignoring the {sup 210}Bi in-growth in {sup 210}Po determinations lead to significant differences (could reach until 100%) between the estimation of {sup 210}Po activity and its true value.

  11. Ambient Air Sampling During Quantum-dot Spray Deposition

    SciTech Connect

    Jankovic, John Timothy; Hollenbeck, Scott M

    2010-01-01

    Ambient air sampling for nano-size particle emissions was performed during spot spray coating operations with a Sono-Tek Exactacoat Benchtop system (ECB). The ECB consisted of the application equipment contained within an exhaust enclosure. The enclosure contained numerous small access openings, including an exhaust hook-up. Door access comprised most of the width and height of the front. The door itself was of the swing-out type. Two types of nanomaterials, Cadmium selenide (Cd-Se) quantum-dots (QDs) and Gold (Au) QDs, nominally 3.3 and 5 nm in diameter respectively, were applied during the evaluation. Median spray drop size was in the 20 to 60 micrometer size range.1 Surface coating tests were of short duration, on the order of one-half second per spray and ten spray applications between door openings. The enclosure was ventilated by connection to a high efficiency particulate aerosol (HEPA) filtered house exhaust system. The exhaust rate was nominally 80 ft3 per minute producing about 5 air changes per minute. Real time air monitoring with a scanning mobility particle size analyzer (SMPS ) with a size detection limit of 7 nm indicated a significant increase in the ambient air concentration upon early door opening. A handheld condensation particle counter (CPC) with a lower size limit of 10 nm did not record changes in the ambient background. This increase in the ambient was not observed when door opening was delayed for 2 minutes (~10 air changes). The ventilated enclosure controlled emissions except for cases of rapid door opening before the overspray could be removed by the exhaust. A time delay sufficient to provide 10 enclosure air changes (a concentration reduction of more than 99.99 %) before door opening prevented the release of aerosol particles in any size.2 Scanning-transmission electron microscopy (STEM) and atomic force microscopy (AFM) demonstrated the presence of agglomerates in the surfaces of the spray applied deposition. A filtered air sample of

  12. Quick-change filter cartridge

    DOEpatents

    Rodgers, John C.; McFarland, Andrew R.; Ortiz, Carlos A.

    1995-01-01

    A quick-change filter cartridge. In sampling systems for measurement of airborne materials, a filter element is introduced into the sampled airstream such that the aerosol constituents are removed and deposited on the filter. Fragile sampling media often require support in order to prevent rupture during sampling, and careful mounting and sealing to prevent misalignment, tearing, or creasing which would allow the sampled air to bypass the filter. Additionally, handling of filter elements may introduce cross-contamination or exposure of operators to toxic materials. Moreover, it is desirable to enable the preloading of filter media into quick-change cartridges in clean laboratory environments, thereby simplifying and expediting the filter-changing process in the field. The quick-change filter cartridge of the present invention permits the application of a variety of filter media in many types of instruments and may also be used in automated systems. The cartridge includes a base through which a vacuum can be applied to draw air through the filter medium which is located on a porous filter support and held there by means of a cap which forms an airtight seal with the base. The base is also adapted for receiving absorbing media so that both particulates and gas-phase samples may be trapped for investigation, the latter downstream of the aerosol filter.

  13. Comparative Proteomics Reveals Novel Components at the Plasma Membrane of Differentiated HepaRG Cells and Different Distribution in Hepatocyte- and Biliary-Like Cells

    PubMed Central

    Woods, Alisa G.; Lazar, Catalin; Radu, Gabriel L.; Darie, Costel C.; Branza-Nichita, Norica

    2013-01-01

    Hepatitis B virus (HBV) is a human pathogen causing severe liver disease and eventually death. Despite important progress in deciphering HBV internalization, the early virus-cell interactions leading to infection are not known. HepaRG is a human bipotent liver cell line bearing the unique ability to differentiate towards a mixture of hepatocyte- and biliary-like cells. In addition to expressing metabolic functions normally found in liver, differentiated HepaRG cells support HBV infection in vitro, thus resembling cultured primary hepatocytes more than other hepatoma cells. Therefore, extensive characterization of the plasma membrane proteome from HepaRG cells would allow the identification of new cellular factors potentially involved in infection. Here we analyzed the plasma membranes of non-differentiated and differentiated HepaRG cells using nanoliquid chromatography-tandem mass spectrometry to identify the differences between the proteomes and the changes that lead to differentiation of these cells. We followed up on differentially-regulated proteins in hepatocytes- and biliary-like cells, focusing on Cathepsins D and K, Cyclophilin A, Annexin 1/A1, PDI and PDI A4/ERp72. Major differences between the two proteomes were found, including differentially regulated proteins, protein-protein interactions and intracellular localizations following differentiation. The results advance our current understanding of HepaRG differentiation and the unique properties of these cells. PMID:23977166

  14. Differential toxicity of heterocyclic aromatic amines and their mixture in metabolically competent HepaRG cells

    SciTech Connect

    Dumont, Julie; Josse, Rozenn; Lambert, Carine; Antherieu, Sebastien; Le Hegarat, Ludovic; Aninat, Caroline; Robin, Marie-Anne; Guguen-Guillouzo, Christiane

    2010-06-01

    Human exposure to heterocyclic aromatic amines (HAA) usually occurs through mixtures rather than individual compounds. However, the toxic effects and related mechanisms of co-exposure to HAA in humans remain unknown. We compared the effects of two of the most common HAA, 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) and 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx), individually or in combination, in the metabolically competent human hepatoma HepaRG cells. Various endpoints were measured including cytotoxicity, apoptosis, oxidative stress and DNA damage by the comet assay. Moreover, the effects of PhIP and/or MeIQx on mRNA expression and activities of enzymes involved in their activation and detoxification pathways were evaluated. After a 24 h treatment, PhIP and MeIQx, individually and in combination, exerted differential effects on apoptosis, oxidative stress, DNA damage and cytochrome P450 (CYP) activities. Only PhIP induced DNA damage. It was also a stronger inducer of CYP1A1 and CYP1B1 expression and activity than MeIQx. In contrast, only MeIQx exposure resulted in a significant induction of CYP1A2 activity. The combination of PhIP with MeIQx induced an oxidative stress and showed synergistic effects on apoptosis. However, PhIP-induced genotoxicity was abolished by a co-exposure with MeIQx. Such an inhibitory effect could be explained by a significant decrease in CYP1A2 activity which is responsible for PhIP genotoxicity. Our findings highlight the need to investigate interactions between HAA when assessing risks for human health and provide new insights in the mechanisms of interaction between PhIP and MeIQx.

  15. System and Apparatus for Filtering Particles

    NASA Technical Reports Server (NTRS)

    Agui, Juan H. (Inventor); Vijayakumar, Rajagopal (Inventor)

    2015-01-01

    A modular pre-filtration apparatus may be beneficial to extend the life of a filter. The apparatus may include an impactor that can collect a first set of particles in the air, and a scroll filter that can collect a second set of particles in the air. A filter may follow the pre-filtration apparatus, thus causing the life of the filter to be increased.

  16. A modified multiparametric assay using HepaRG cells for predicting the degree of drug-induced liver injury risk.

    PubMed

    Tomida, Takafumi; Okamura, Hayao; Yokoi, Tsuyoshi; Konno, Yoshihiro

    2017-03-01

    The approach for predicting the degree of drug-induced liver injury (DILI) risk was investigated quantitatively in a modified multiparametric assay using HepaRG cells. Thirty-eight drugs were classified by DILI risk into five categories based on drug labels approved by the Food and Drug Administration (FDA) as follows: withdrawn (WDN), boxed warning (BW), warnings and precautions (WP), adverse reactions (AR), and no match (NM). Also, WP was classified into two categories: high and low concern. Differentiated HepaRG cells were treated with drugs for 24 h. The maximum concentration was set at 100-fold the therapeutic maximum plasma concentration (Cmax ). After treatment with drugs, the cell viability, glutathione content, caspase 3/7 activity, lactate dehydrogenase leakage and albumin secretion were measured. As modified cut-off values of each parameter, the TC50 (toxic concentration that decreased the response by 50%) and EC200 (effective concentration giving a response equal to 200% of controls) were calculated. In addition, the toxicity score (total sum score of the cytotoxic level of each parameter) was calculated. This modified multiparametric assay showed an 87% sensitivity and 87% specificity for predicting the DILI risk. The toxicity score showed a good predictive performance for WDN, BW and WP (high concern) categories [cut-off: score ≥ 1; area under a receiver operating characteristic curve (ROC-AUC): 0.88], and for WDN and BW categories (cut-off: score ≥ 3; ROC-AUC: 0.88). This study newly indicated that the degree of DILI risk might be predictable quantitatively by assessing the toxicity score in the modified multiparametric assay using HepaRG cells. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Biokinetics of chlorpromazine in primary rat and human hepatocytes and human HepaRG cells after repeated exposure.

    PubMed

    Broeders, Jessica J W; Parmentier, Céline; Truisi, Germaine L; Jossé, Rozenn; Alexandre, Eliane; Savary, Camille C; Hewitt, Philip G; Mueller, Stefan O; Guillouzo, André; Richert, Lysiane; van Eijkeren, Jan C H; Hermens, Joop L M; Blaauboer, Bas J

    2015-12-25

    Since drug induced liver injury is difficult to predict in animal models, more representative tests are needed to better evaluate these effects in humans. Existing in vitro systems hold great potential to detect hepatotoxicity of pharmaceuticals. In this study, the in vitro biokinetics of the model hepatotoxicant chlorpromazine (CPZ) were evaluated in three different liver cell systems after repeated exposure in order to incorporate repeated-dose testing into an in vitro assay. Primary rat and human hepatocytes, cultured in sandwich configuration and the human HepaRG cell line were treated daily with CPZ for 14 days. Samples were taken from medium, cells and well plastic at specific time points after the first and last exposure. The samples were analysed by HPLC-UV to determine the amount of CPZ in these samples. Based on cytotoxicity assays, the three models were tested at 1-2 μM CPZ, while the primary rat hepatocytes and the HepaRG cell line were in addition exposed to a higher concentration of 15-20 μM. Overall, the mass balance of CPZ decreased in the course of 24 h, indicating the metabolism of the compound within the cells. The largest decrease in parent compound was seen in the primary cultures; in the HepaRG cell cultures the mass balance only decreased to 50%. CPZ accumulated in the cells during the 14-day repeated exposure. Possible explanations for the accumulation of CPZ are a decrease in metabolism over time, inhibition of efflux transporters or binding to phospholipids. The biokinetics of CPZ differed between the three liver cell models and were influenced by specific cell properties as well as culture conditions. These results support the conclusion that in vitro biokinetics data are necessary to better interpret chemical-induced cytotoxicity data.

  18. In Vivo Evaluation of a New Embolic Spherical Particle (HepaSphere) in a Kidney Animal Model

    SciTech Connect

    Luis, Esther de Bilbao, Jose I.; Ciercoles, Jose A. Garcia Jalon de; Martinez-Cuesta, Antonio; Martino Rodriguez, Alba de; Lozano, Maria D.

    2008-03-15

    HepaSphere is a new spherical embolic material developed in a dry state that absorbs fluids and adapts to the vessel wall, leaving no space between the particle and the arterial wall. The aim of this study was to elucidate the final in vivo size, deformation, final location, and main properties of the particles when reconstituted with two different contrast media (Iodixanol and Ioxaglate) in an animal model. Two sizes of 'dry-state' particles (50-100 and 150-200 {mu}m) were reconstituted using both ionic and nonionic contrast media. The mixture was used to partly embolize both kidneys in an animal model (14 pigs). The animals were sacrificed 4 weeks after the procedure and the samples processed. The final size of the particles was 230.2 {+-} 62.5 {mu}m for the 50- to 100-{mu}m dry-state particles and 314.4 {+-} 71 {mu}m for the 150- to 200-{mu}m dry-state particles. When the contrast medium (ionic versus nonionic) used for the reconstitution was studied to compare (Student's t-test) the final size of the particles, no differences were found (p > 0.05). The mean in vivo deformation for HepaSphere was 17.1% {+-} 12.3%. No differences (p > 0.05) were found in the deformation of the particle regarding the dry-state size or the contrast medium (Mann-Whitney test). We conclude that HepaSphere is stable, occludes perfectly, and morphologically adapts to the vessel lumen of the arteries embolized. There is no recanalization of the arteries 4 weeks after embolization. Its final in vivo size is predictable and the particle has the same properties in terms of size and deformation with the two different contrast media (Iodixanol and Ioxaglate)

  19. Protective effect of Porphyra yezoensis glycoprotein on D-galactosamine‑induced cytotoxicity in Hepa 1c1c7 cells.

    PubMed

    Choi, Jeong-Wook; Kim, Young-Min; Park, Su-Jin; Kim, In-Hye; Nam, Taek-Jeong

    2015-05-01

    The present study aimed to examine the signaling pathways and enzyme activity associated with the protective effect of Porphyra yezoensis glycoprotein (PYGP) on D‑galactosamine (D‑GaIN)‑induced cytotoxicity in Hepa 1c1c7 cells. D‑GaIN is commonly used to induce hepatic injury models in vivo as well as in vitro. PYGP was extracted from Porphyra yezoensis, a red algae distributed along the coasts of Republic of Korea, China and Japan. In the present study, Hepa 1c1c7 cells were pre‑treated with PYGP (20 and 40 µg/ml) for 24 h and then the media was replaced with D‑GaIN (20 mM) and PYGP (20 and 40 µg/ml). The results demonstrated that D‑GaIN induced Hepa 1c1c7 cell death and pretreatment with PYGP was found to attenuate D‑GaIN toxicity. In addition, D‑GaIN decreased the antioxidant activity and increased lipid peroxidation processes; however, pre‑treatment with PYGP reduced the generation of lipid peroxidation products, such as thiobarbituric acid reactive substances, as well as increased the activity of antioxidant enzymes, including superoxide dismutase, catalase and glutathione‑s‑transferase (GST). PYGP was shown to suppress the overexpression of extracellular signal‑regulated kinase, c‑jun N‑terminal kinase and p38 mitogen‑activated protein kinase (MAPK) phosphorylation induced by D‑GaIN. Furthermore, PYGP increased the protein expression of nuclear factor erythroid 2‑related factor 2 (Nrf2), quinine oxidoreductase 1, GST and heme oxygenase 1 protein expression. These results suggested that PYGP had cytoprotective effects against D‑GaIN‑induced cell damage, which may be associated with MAPKs and the Nrf2 signaling pathway.

  20. Water Filters

    NASA Technical Reports Server (NTRS)

    1993-01-01

    The Aquaspace H2OME Guardian Water Filter, available through Western Water International, Inc., reduces lead in water supplies. The filter is mounted on the faucet and the filter cartridge is placed in the "dead space" between sink and wall. This filter is one of several new filtration devices using the Aquaspace compound filter media, which combines company developed and NASA technology. Aquaspace filters are used in industrial, commercial, residential, and recreational environments as well as by developing nations where water is highly contaminated.

  1. Biological Filters.

    ERIC Educational Resources Information Center

    Klemetson, S. L.

    1978-01-01

    Presents the 1978 literature review of wastewater treatment. The review is concerned with biological filters, and it covers: (1) trickling filters; (2) rotating biological contractors; and (3) miscellaneous reactors. A list of 14 references is also presented. (HM)

  2. Metallic Filters

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Filtration technology originated in a mid 1960's NASA study. The results were distributed to the filter industry, an HR Textron responded, using the study as a departure for the development of 421 Filter Media. The HR system is composed of ultrafine steel fibers metallurgically bonded and compressed so that the pore structure is locked in place. The filters are used to filter polyesters, plastics, to remove hydrocarbon streams, etc. Several major companies use the product in chemical applications, pollution control, etc.

  3. Filter validation.

    PubMed

    Madsen, Russell E

    2006-01-01

    Validation of a sterilizing filtration process is critical since it is impossible with currently available technology to measure the sterility of each filled container; therefore, sterility assurance of the filtered product must be achieved through validation of the filtration process. Validating a pharmaceutical sterile filtration process involves three things: determining the effect of the liquid on the filter, determining the effect of the filter on the liquid, and demonstrating that the filter removes all microorganisms from the liquid under actual processing conditions.

  4. 40 CFR 63.548 - Monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... inspection of fans for wear, material buildup, and corrosion through visual inspection, vibration detectors...) Baghouses equipped with high efficiency particulate air (or HEPA) filters as a secondary filter used...

  5. 40 CFR 63.548 - Monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... inspection of fans for wear, material buildup, and corrosion through visual inspection, vibration detectors...) Baghouses equipped with high efficiency particulate air (or HEPA) filters as a secondary filter used...

  6. 40 CFR 63.548 - Monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... inspection of fans for wear, material buildup, and corrosion through visual inspection, vibration detectors...) Baghouses equipped with high efficiency particulate air (or HEPA) filters as a secondary filter used...

  7. Ozone decomposing filter

    SciTech Connect

    Simandl, R.F.; Brown, J.D.; Whinnery, L.L. Jr.

    1999-11-02

    In an improved ozone decomposing air filter carbon fibers are held together with a carbonized binder in a perforated structure. The structure is made by combining rayon fibers with gelatin, forming the mixture in a mold, freeze-drying, and vacuum baking.

  8. Ozone decomposing filter

    DOEpatents

    Simandl, Ronald F.; Brown, John D.; Whinnery, Jr., LeRoy L.

    1999-01-01

    In an improved ozone decomposing air filter carbon fibers are held together with a carbonized binder in a perforated structure. The structure is made by combining rayon fibers with gelatin, forming the mixture in a mold, freeze-drying, and vacuum baking.

  9. FILTER TREATMENT

    DOEpatents

    Sutton, J.B.; Torrey, J.V.P.

    1958-08-26

    A process is described for reconditioning fused alumina filters which have become clogged by the accretion of bismuth phosphate in the filter pores, The method consists in contacting such filters with faming sulfuric acid, and maintaining such contact for a substantial period of time.

  10. Water Filters

    NASA Technical Reports Server (NTRS)

    1987-01-01

    A compact, lightweight electrolytic water filter generates silver ions in concentrations of 50 to 100 parts per billion in the water flow system. Silver ions serve as effective bactericide/deodorizers. Ray Ward requested and received from NASA a technical information package on the Shuttle filter, and used it as basis for his own initial development, a home use filter.

  11. Ten-year air sample analysis of Aspergillus prevalence in a university hospital.

    PubMed

    Falvey, D G; Streifel, A J

    2007-09-01

    Airborne fungal samples were collected on a monthly basis for 10 years, from 1995 to 2005, at a tertiary university hospital. Paired samples were cultured at 25 and 37 degrees C. Data were interpreted according to the air filtration systems serving each location. Samples cultured at 37 degrees C from the patient care areas had a mean recovery of 18% of the mean recovery from outdoor air (22 versus 122cfu/m(3)). Recovery of Aspergillus spp. at 37 degrees C in the high-efficiency particulate air (HEPA)-filtered locations was positive for Aspergillus spp. approximately one-third of the time; the rest of the patient care areas were positive half of the time and the outdoor samples were positive 95% of the time. We found 48 sporadic bursts at 37 degrees C which produced counts >3 SD above the mean. Hospital-acquired infection was related to high recovery of Aspergillus fumigatus on at least one occasion. We have found it impossible, without implementing impractical measures, to provide an environment completely devoid of Aspergillus spp. We conclude that routine air sampling is not an effective means of predicting hospital-acquired infections. However, a transient spike, or burst, may be useful in identifying an in-house source of contamination and may be used to consider additional interventional treatments for patients at risk. Emphasis should be placed on maintaining high-efficiency filtration of the outside air and on ensuring that other environmental control methods are used to prevent dissemination of environmental opportunistic fungal spores.

  12. The rodent malaria liver stage survives in the rapamycin-induced autophagosome of infected Hepa1–6 cells

    PubMed Central

    Zhao, Chenghao; Liu, Taiping; Zhou, Taoli; Fu, Yong; Zheng, Hong; Ding, Yan; Zhang, Kun; Xu, Wenyue

    2016-01-01

    It has been reported that non-selective autophagy of infected hepatocytes could facilitate the development of malaria in the liver stage, but the fate of parasites following selective autophagy of infected hepatocytes is still not very clear. Here, we confirmed that sporozoite infection can induce a selective autophagy-like process targeting EEFs (exo-erythrocytic forms) in Hepa1–6. Rapamycin treatment greatly enhanced this process in EEFs and non-selective autophagy of infected Hepa1-6 cells and enhanced the development of the malaria liver stage in vivo. Although rapamycin promoted the fusion of autophagosomes containing the malaria parasite with lysosomes, some parasites inside the autophagosome survived and replicated normally. Further study showed that the maturation of affected autolysosomes was greatly inhibited. Therefore, in addition to the previously described positive role of rapamycin-induced nonselective autophagy of hepatocytes, we provide evidence that the survival of EEFs in the autophagosome of the infected hepatocytes also contributes to rapamycin-enhanced development of the malaria liver stage, possibly due to the suppression of autolysosome maturation by EEFs. These data suggest that the inhibition of autolysosome maturation might be a novel escape strategy used by the malaria liver stage. PMID:27901110

  13. Walking in the high-rise city: a Health Enhancement and Pedometer-determined Ambulatory (HEPA) program in Hong Kong.

    PubMed

    Leung, Angela Y M; Cheung, Mike K T; Tse, Michael A; Shum, Wai Chuen; Lancaster, B J; Lam, Cindy L K

    2014-01-01

    Due to the lack of good infrastructure in the public estates, many older adults in urban areas are sedentary. The Health Enhancement and Pedometer-Determined Ambulatory (HEPA) program was developed to assist older adults with diabetes and/or hypertension to acquire walking exercise habits and to build social support, while engaged in regular physical activity. This study aimed to describe the HEPA program and to report changes in participants' walking capacity and body strength after 10-week walking sessions. A pre- and postintervention design was used. Pedometers were used to measure the number of steps taken per day before and after the 10-week intervention. Upper and lower body strength, lower body flexibility, and quality of life were assessed. A total of 205 older adults completed the program and all health assessments. After the 10-week intervention, the average number of steps per day increased by 36%, from 6,591 to 8,934. Lower body strength, upper body strength, and aerobic fitness increased significantly after 10 weeks, along with improvement in the 12-item Short Form Health Survey (SF™-12) physical and mental health component summary scores. A social support network was built in the neighborhood, and the local environment was utilized to make walking possible and enjoyable.

  14. Walking in the high-rise city: a Health Enhancement and Pedometer-determined Ambulatory (HEPA) program in Hong Kong

    PubMed Central

    Leung, Angela YM; Cheung, Mike KT; Tse, Michael A; Shum, Wai Chuen; Lancaster, BJ; Lam, Cindy LK

    2014-01-01

    Due to the lack of good infrastructure in the public estates, many older adults in urban areas are sedentary. The Health Enhancement and Pedometer-Determined Ambulatory (HEPA) program was developed to assist older adults with diabetes and/or hypertension to acquire walking exercise habits and to build social support, while engaged in regular physical activity. This study aimed to describe the HEPA program and to report changes in participants’ walking capacity and body strength after 10-week walking sessions. A pre- and postintervention design was used. Pedometers were used to measure the number of steps taken per day before and after the 10-week intervention. Upper and lower body strength, lower body flexibility, and quality of life were assessed. A total of 205 older adults completed the program and all health assessments. After the 10-week intervention, the average number of steps per day increased by 36%, from 6,591 to 8,934. Lower body strength, upper body strength, and aerobic fitness increased significantly after 10 weeks, along with improvement in the 12-item Short Form Health Survey (SF™-12) physical and mental health component summary scores. A social support network was built in the neighborhood, and the local environment was utilized to make walking possible and enjoyable. PMID:25170259

  15. Personal cooling air filtering device

    DOEpatents

    Klett, James [Knoxville, TN; Conway, Bret [Denver, NC

    2002-08-13

    A temperature modification system for modifying the temperature of fluids includes at least one thermally conductive carbon foam element, the carbon foam element having at least one flow channel for the passage of fluids. At least one temperature modification device is provided, the temperature modification device thermally connected to the carbon foam element and adapted to modify the temperature of the carbon foam to modify the temperature of fluids flowing through the flow channels. Thermoelectric and/or thermoionic elements can preferably be used as the temperature modification device. A method for the reversible temperature modification of fluids includes the steps of providing a temperature modification system including at least one thermally conductive carbon foam element having flow channels and at least one temperature modification device, and flowing a fluid through the flow channels.

  16. [Radiation exposure and air quality aboard commercial airplanes].

    PubMed

    Bergau, L

    1999-10-01

    The amount of exposure to cosmic radiation during air travel is next to a number of additional factors mainly dependent on the flight level of the aircraft. Flying in an altitude of 41,000 feet equaling 12,800 meters the amount of radiation exposure is of course considerable higher than on the ground. The overall exposure of flying personnel to cosmic radiation flying about 600-700 hours per year can be estimated between 3 and 6 mSv (300-600 mrem). According to the flight hours of passengers, the radiation exposure is much lower and can be neglected for most of the travelers final judgement about the possible risks for flying personnel as far as a higher incident of malignant tumors is concerned has not jet been finally made. Talking of cabin air quality compromises have to be made and thus the well-being of the passengers can be negatively influenced. Air pressure and oxygen partial pressure correspond to an altitude of 2400 meters (8,000 feet) above sea level with possible consequences to the cardiopulmonary system. Increased level of ozone can lead to respiratory problems of the upper airways, increased carbon dioxide may cause hyperventilation. The mucous membranes of the respiratory tract are dried out due to the extremely low humidity of the cabin air. Smoking during flight results in an increase of the nicotine blood levels even in passengers sitting in the non-smoking areas. In modern aircraft the fresh-air flow cannot be regulated individually any more, this may lead to an insufficient circulation of used air in relation to fresh air and could cause the phenomena of hanging smoke. There has always been the idea that there is an increased risk for passengers for acquiring infectious diseases. However this is not the case. Modern HEPA-filter prevent an accumulation even of the smallest particles including bacteria and viruses within the recirculation flow in the cabin air. The overall risk of getting an infectious disease is significantly lower than in other

  17. Variational filtering.

    PubMed

    Friston, K J

    2008-07-01

    This note presents a simple Bayesian filtering scheme, using variational calculus, for inference on the hidden states of dynamic systems. Variational filtering is a stochastic scheme that propagates particles over a changing variational energy landscape, such that their sample density approximates the conditional density of hidden and states and inputs. The key innovation, on which variational filtering rests, is a formulation in generalised coordinates of motion. This renders the scheme much simpler and more versatile than existing approaches, such as those based on particle filtering. We demonstrate variational filtering using simulated and real data from hemodynamic systems studied in neuroimaging and provide comparative evaluations using particle filtering and the fixed-form homologue of variational filtering, namely dynamic expectation maximisation.

  18. Characterizing ultrafine particles and other air pollutants in and around school buses.

    PubMed

    Zhu, Yifang; Zhang, Qunfang

    2014-03-01

    Increasing evidence has demonstrated toxic effects of ultrafine particles (UFP*, diameter < 100 nm). Children are particularly at risk because of their immature respiratory systems and higher breathing rates per body mass. This study aimed to characterize UFP, PM2.5 (particulate matter < or = 2.5 microm in aerodynamic diameter), and other vehicular-emitted pollutants in and around school buses. Four sub-studies were conducted, including: 1. On-road tests to measure in-cabin air pollutant levels while school buses were being driven; 2. Idling tests to determine the contributions of tailpipe emissions from idling school buses to air pollutant levels in and around school buses under different scenarios; 3. Retrofit tests to evaluate the performance of two retrofit systems, a diesel oxidation catalyst (DOC) muffler and a crankcase filtration system (CFS), on reducing tailpipe emissions and in-cabin air pollutant concentrations under idling and driving conditions; and 4. High efficiency particulate air (HEPA) filter air purifier tests to evaluate the effectiveness of in-cabin filtration. In total, 24 school buses were employed to cover a wide range of school buses commonly used in the United States. Real-time air quality measurements included particle number concentration (PNC), fine and UFP size distribution in the size range 7.6-289 nm, PM2.5 mass concentration, black carbon (BC) concentration, and carbon monoxide (CO) and carbon dioxide (CO2) concentrations. For in-cabin measurements, instruments were placed on a platform secured to the rear seats inside the school buses. For all other tests, a second set of instruments was deployed to simultaneously measure the ambient air pollutant levels. For tailpipe emission measurements, the exhaust was diluted and then measured by instruments identical to those used for the in-cabin measurements. The results show that when driving on roads, in-cabin PNC, fine and UFP size distribution, PM2.5, BC, and CO varied by engine age

  19. MicroRNA Responses to the Genotoxic Carcinogens Aflatoxin B1 and Benzo[a]pyrene in Human HepaRG Cells.

    PubMed

    Marrone, April K; Tryndyak, Volodymyr; Beland, Frederick A; Pogribny, Igor P

    2016-02-01

    Recent advances in toxicogenomics present an opportunity to develop new in vitro testing methodologies to identify human carcinogens. We have investigated microRNA expression responses to the treatment of human liver HepaRG cells with the human genotoxic carcinogens aflatoxin B1 (AFB1) and benzo[a]pyrene (B[a]P), and the structurally similar compounds aflatoxin B2 (AFB2) and benzo[e]pyrene (B[e]P) that exhibit minimal carcinogenic potential. We demonstrate that treatment of HepaRG cells with AFB1 or B[a]P resulted in specific changes in the expression of miRNAs as compared with their non-carcinogenic analogues, particularly in a marked over-expression of miR-410. An additional novel finding is the dose- and time-dependent inhibition of miR-122 in AFB1-treated HepaRG cells. Mechanistically, the AFB1-induced down-regulation of miR-122 was attributed to inhibition of the HNF4A/miR-122 regulatory pathway. These results demonstrate that HepaRG cells can be used to investigate miRNA responses to xenobiotic exposure, and illustrate the existence of early non-genotoxic events, in addition to a well-established genotoxic mode of action changes, in the mechanism of AFB1 and B[a]P carcinogenicity.

  20. Reliability and Validity of the SE-HEPA: Examining Physical Activity- and Healthy Eating-Specific Self-Efficacy among a Sample of Preadolescents

    ERIC Educational Resources Information Center

    Steele, Michael M.; Burns, Leonard G.; Whitaker, Brandi N.

    2013-01-01

    Objective. The purpose of this study was to examine the psychometric properties of the self-efficacy for healthy eating and physical activity measure (SE-HEPA) for preadolescents. Method. The reliability of the measure was examined to determine if the internal consistency of the measure was adequate (i.e., [alpha]s greater than 0.70). Next, in an…

  1. Isokinetic air sampler

    DOEpatents

    Sehmel, George A.

    1979-01-01

    An isokinetic air sampler includes a filter, a holder for the filter, an air pump for drawing air through the filter at a fixed, predetermined rate, an inlet assembly for the sampler having an inlet opening therein of a size such that isokinetic air sampling is obtained at a particular wind speed, a closure for the inlet opening and means for simultaneously opening the closure and turning on the air pump when the wind speed is such that isokinetic air sampling is obtained. A system incorporating a plurality of such samplers provided with air pumps set to draw air through the filter at the same fixed, predetermined rate and having different inlet opening sizes for use at different wind speeds is included within the ambit of the present invention as is a method of sampling air to measure airborne concentrations of particulate pollutants as a function of wind speed.

  2. Optimization of integrated polarization filters.

    PubMed

    Gagnon, Denis; Dumont, Joey; Déziel, Jean-Luc; Dubé, Louis J

    2014-10-01

    This study reports on the design of small footprint, integrated polarization filters based on engineered photonic lattices. Using a rods-in-air lattice as a basis for a TE filter and a holes-in-slab lattice for the analogous TM filter, we are able to maximize the degree of polarization of the output beams up to 98% with a transmission efficiency greater than 75%. The proposed designs allow not only for logical polarization filtering, but can also be tailored to output an arbitrary transverse beam profile. The lattice configurations are found using a recently proposed parallel tabu search algorithm for combinatorial optimization problems in integrated photonics.

  3. Automated detection of hepatotoxic compounds in human hepatocytes using HepaRG cells and image-based analysis of mitochondrial dysfunction with JC-1 dye

    SciTech Connect

    Pernelle, K.; Le Guevel, R.; Glaise, D.; Stasio, C. Gaucher-Di; Le Charpentier, T.; Bouaita, B.; Corlu, A.; Guguen-Guillouzo, C.

    2011-08-01

    In this study, our goal was to develop an efficient in situ test adapted to screen hepatotoxicity of various chemicals, a process which remains challenging during the early phase of drug development. The test was based on functional human hepatocytes using the HepaRG cell line, and automation of quantitative fluorescence microscopy coupled with automated imaging analysis. Differentiated HepaRG cells express most of the specific liver functions at levels close to those found in primary human hepatocytes, including detoxifying enzymes and drug transporters. A triparametric analysis was first used to evaluate hepatocyte purity and differentiation status, mainly detoxication capacity of cells before toxicity testing. We demonstrated that culturing HepaRG cells at high density maintained high hepatocyte purity and differentiation level. Moreover, evidence was found that isolating hepatocytes from 2-week-old confluent cultures limited variations associated with an ageing process occurring over time in confluent cells. Then, we designed a toxicity test based on detection of early mitochondrial depolarisation associated with permeability transition (MPT) pore opening, using JC-1 as a metachromatic fluorescent dye. Maximal dye dimerization that would have been strongly hampered by efficient efflux due to the active, multidrug-resistant (MDR) pump was overcome by coupling JC-1 with the MDR inhibitor verapamil. Specificity of this test was demonstrated and its usefulness appeared directly dependent on conditions supporting hepatic cell competence. This new hepatotoxicity test adapted to automated, image-based detection should be useful to evaluate the early MPT event common to cell apoptosis and necrosis and simultaneously to detect involvement of the multidrug resistant pump with target drugs in a human hepatocyte environment. - Highlights: > We define conditions to preserve differentiation of selective pure HepaRG hepatocyte cultures. > In these conditions, CYPs

  4. Personal continuous air monitor

    DOEpatents

    Morgan, Ronald G.; Salazar, Samuel A.

    2000-01-01

    A personal continuous air monitor capable of giving immediate warning of the presence of radioactivity has a filter/detector head to be worn in the breathing zone of a user, containing a filter mounted adjacent to radiation detectors, and a preamplifier. The filter/detector head is connected to a belt pack to be worn at the waist or on the back of a user. The belt pack contains a signal processor, batteries, a multichannel analyzer, a logic circuit, and an alarm. An air pump also is provided in the belt pack for pulling air through the filter/detector head by way of an air tube.

  5. Filtering apparatus

    DOEpatents

    Haldipur, Gaurang B.; Dilmore, William J.

    1992-01-01

    A vertical vessel having a lower inlet and an upper outlet enclosure separated by a main horizontal tube sheet. The inlet enclosure receives the flue gas from a boiler of a power system and the outlet enclosure supplies cleaned gas to the turbines. The inlet enclosure contains a plurality of particulate-removing clusters, each having a plurality of filter units. Each filter unit includes a filter clean-gas chamber defined by a plate and a perforated auxiliary tube sheet with filter tubes suspended from each tube sheet and a tube connected to each chamber for passing cleaned gas to the outlet enclosure. The clusters are suspended from the main tube sheet with their filter units extending vertically and the filter tubes passing through the tube sheet and opening in the outlet enclosure. The flue gas is circulated about the outside surfaces of the filter tubes and the particulate is absorbed in the pores of the filter tubes. Pulses to clean the filter tubes are passed through their inner holes through tubes free of bends which are aligned with the tubes that pass the clean gas.

  6. Filtering apparatus

    DOEpatents

    Haldipur, G.B.; Dilmore, W.J.

    1992-09-01

    A vertical vessel is described having a lower inlet and an upper outlet enclosure separated by a main horizontal tube sheet. The inlet enclosure receives the flue gas from a boiler of a power system and the outlet enclosure supplies cleaned gas to the turbines. The inlet enclosure contains a plurality of particulate-removing clusters, each having a plurality of filter units. Each filter unit includes a filter clean-gas chamber defined by a plate and a perforated auxiliary tube sheet with filter tubes suspended from each tube sheet and a tube connected to each chamber for passing cleaned gas to the outlet enclosure. The clusters are suspended from the main tube sheet with their filter units extending vertically and the filter tubes passing through the tube sheet and opening in the outlet enclosure. The flue gas is circulated about the outside surfaces of the filter tubes and the particulate is absorbed in the pores of the filter tubes. Pulses to clean the filter tubes are passed through their inner holes through tubes free of bends which are aligned with the tubes that pass the clean gas. 18 figs.

  7. Application of Kolomogorov-Zurbenko Filter and the decoupled direct 3D method for the dynamic evaluation of a regional air quality model

    EPA Science Inventory

    Regional air quality models are being used in a policy-setting to estimate the response of air pollutant concentrations to changes in emissions and meteorology. Dynamic evaluation entails examination of a retrospective case(s) to assess whether an air quality model has properly p...

  8. DIFFERENTIAL REGULATION OF POLYSOME mRNA LEVELS IN MOUSE HEPA-1C1C7 CELLS EXPOSED TO DIOXIN

    PubMed Central

    Thornley, Jessica A.; Trask, Heidi W.; Ridley, Christian J. A.; Korc, Murray; Gui, Jiang; Ringelberg, Carol S.; Wang, Sinny; Tomlinson, Craig R.

    2011-01-01

    The environmental agent 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD or dioxin) causes a multitude of human illnesses. In order to more fully understand the underlying biology of TCDD toxicity, we tested the hypothesis that new candidate genes could be identified using polysome RNA from TCDD-treated mouse Hepa-1c1c7 cells. We found that (i) differentially expressed whole cell and cytoplasm RNA levels are both poor predictors of polysome RNA levels; (ii) for a majority of RNAs, differential RNA levels are regulated independently in the nucleus, cytoplasm, and polysomes; (iii) for the remaining polysome RNAs, levels are regulated via several different mechanisms, including a “tagging” of mRNAs in the nucleus for immediate polysome entry; and (iv) most importantly, a gene list derived from differentially expressed polysome RNA generated new genes and cell pathways potentially related to TCDD biology. PMID:21570461

  9. Ciliatoxicity in human primary bronchiolar epithelial cells after repeated exposure at the air-liquid interface with native mainstream smoke of K3R4F cigarettes with and without charcoal filter.

    PubMed

    Aufderheide, Michaela; Scheffler, Stefanie; Ito, Shigeaki; Ishikawa, Shinkichi; Emura, Makito

    2015-01-01

    Mucociliary clearance is the primary physical mechanism to protect the human airways against harmful effects of inhaled particles. Environmental factors play a significant role in the impairment of this defense mechanism, whereas cigarette smoke is discussed to be one of the clinically most important causes. Impaired mucociliary clearance in smokers has been connected to changes in ciliated cells such as decreased numbers, altered structure and beat frequency. Clinical studies have shown that cilia length is reduced in healthy smokers and that long-term exposure to cigarette smoke leads to reduced numbers of ciliated cells in mice. We present an in vitro model of primary normal human bronchiolar epithelial (NHBE) cells with in vivo like morphology to study the influence of cigarette mainstream smoke on ciliated cells. We exposed mucociliary differentiated cultures repeatedly to non-toxic concentrations of mainstream cigarette smoke (4 cigarettes, 5 days/week, 8 repetitions in total) at the air-liquid interface. Charcoal filter tipped cigarettes were compared to those being equipped with standard cellulose acetate filters. Histopathological analyses of the exposed cultures showed a reduction of cilia bearing cells, shortening of existing cilia and finally disappearance of all cilia in cigarette smoke exposed cells. In cultures exposed to charcoal filtered cigarette smoke, little changes in cilia length were seen after four exposure repetitions, but those effects were reversed after a two day recovery period. Those differences indicate that volatile organic compounds, being removed by the charcoal filter tip, affect primary bronchiolar epithelial cells concerning their cilia formation and function comparable with the in vivo situation. In conclusion, our in vitro model presents a valuable tool to study air-borne ciliatoxic compounds.

  10. Ultraviolet filters.

    PubMed

    Shaath, Nadim A

    2010-04-01

    The chemistry, photostability and mechanism of action of ultraviolet filters are reviewed. The worldwide regulatory status of the 55 approved ultraviolet filters and their optical properties are documented. The photostabilty of butyl methoxydibenzoyl methane (avobenzone) is considered and methods to stabilize it in cosmetic formulations are presented.

  11. Tailored liquid chromatography-mass spectrometry analysis improves the coverage of the intracellular metabolome of HepaRG cells.

    PubMed

    Cuykx, Matthias; Negreira, Noelia; Beirnaert, Charlie; Van den Eede, Nele; Rodrigues, Robim; Vanhaecke, Tamara; Laukens, Kris; Covaci, Adrian

    2017-03-03

    Metabolomics protocols are often combined with Liquid Chromatography-Mass Spectrometry (LC-MS) using mostly reversed phase chromatography coupled to accurate mass spectrometry, e.g. quadrupole time-of-flight (QTOF) mass spectrometers to measure as many metabolites as possible. In this study, we optimised the LC-MS separation of cell extracts after fractionation in polar and non-polar fractions. Both phases were analysed separately in a tailored approach in four different runs (two for the non-polar and two for the polar-fraction), each of them specifically adapted to improve the separation of the metabolites present in the extract. This approach improves the coverage of a broad range of the metabolome of the HepaRG cells and the separation of intra-class metabolites. The non-polar fraction was analysed using a C18-column with end-capping, mobile phase compositions were specifically adapted for each ionisation mode using different co-solvents and buffers. The polar extracts were analysed with a mixed mode Hydrophilic Interaction Liquid Chromatography (HILIC) system. Acidic metabolites from glycolysis and the Krebs cycle, together with phosphorylated compounds, were best detected with a method using ion pairing (IP) with tributylamine and separation on a phenyl-hexyl column. Accurate mass detection was performed with the QTOF in MS-mode only using an extended dynamic range to improve the quality of the dataset. Parameters with the greatest impact on the detection were the balance between mass accuracy and linear range, the fragmentor voltage, the capillary voltage, the nozzle voltage, and the nebuliser pressure. By using a tailored approach for the intracellular HepaRG metabolome, consisting of three different LC techniques, over 2200 metabolites can be measured with a high precision and acceptable linear range. The developed method is suited for qualitative untargeted LC-MS metabolomics studies.

  12. Translational control plays a prominent role in the hepatocytic differentiation of HepaRG liver progenitor cells

    PubMed Central

    Parent, Romain; Beretta, Laura

    2008-01-01

    Background We investigated the molecular events associated with the differentiation of liver progenitor cells into functional and polarized hepatocytes, using human HepaRG cells that display potent hepatocytic differentiation-inducible properties and share some features with liver progenitor cells. Results Profiling of total and of polysome-bound transcripts isolated from HepaRG cells undergoing hepatocytic differentiation was performed. A group of 3,071 probe sets was reproducibly regulated by at least 2-fold in total or in polysome-bound RNA populations, upon differentiation. The fold changes in the total and the polysome-bound RNA populations for these 3,071 probe sets were poorly correlated (R = 0.38). Moreover, while the majority of the regulated polysome-bound RNA probe sets were up-regulated upon differentiation, the majority of the regulated probe sets selected from the total RNA population was down-regulated. Genes translationally up-regulated were associated with cell cycle inhibition, increased susceptibility to apoptosis and innate immunity. In contrast, genes transcriptionally up-regulated during differentiation corresponded in the majority to liver-enriched transcripts involved in lipid homeostasis and drug metabolism. Finally, several epithelial and hepato-specific transcripts were strongly induced in the total RNA population but were translationally repressed. Conclusion Translational regulation is the main genomic event associated with hepatocytic differentiation of liver progenitor cells in vitro and targets genes critical for moderating hepatocellular growth, cell death and susceptibility to pathogens. Transcriptional regulation targets specifically liver-enriched transcripts vital for establishing normal hepatic energy homeostasis, cell morphology and polarization. The hepatocytic differentiation is also accompanied by a reduction of the transcript content complexity. PMID:18221535

  13. Foam For Filtering

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Like nature's honeycomb, foam is a structure of many-sided cells, apparently solid but actually only three percent material and 97 percent air. Foam is made by a heat-producing chemical reaction which expands a plastic material in a manner somewhat akin to the heat-induced rising of a loaf of bread. The resulting structure of interconnected cells is flexible yet strong and extremely versatile in applicati6n. Foam can, for example, be a sound absorber in one form, while in another it allows sound to pass through it. It can be a very soft powder puff material and at the same time a highly abrasive scrubber. A sampling of foam uses includes stereo speaker grilles, applying postage meter ink, filtering lawnmower carburetor air; deadening noise in trucks and tractors, applying cosmetics, releasing fabric softener and antistatic agents in home clothes dryers, painting, filtering factory heating and ventilating systems, shining shoes, polishing cars, sponge-mopping floors, acting as pre-operative surgical scrubbers-the list is virtually limitless. The process by which foam is made produces "windows," thin plastic membranes connecting the cell walls. Windowed foam is used in many applications but for certain others-filtering, for example-it is desirable to have a completely open network. Scott Paper Company's Foam Division, Chester, Pennsylvania, improved a patented method of "removing the windows," to create an open structure that affords special utility in filtering applications. NASA technology contributed to Scott's improvement.

  14. SU-E-T-800: Verification of Acurose XB Dose Calculation Algorithm at Air Cavity-Tissue Interface Using Film Measurement for Small Fields of 6-MV Flattening Filter-Free Beams

    SciTech Connect

    Kang, S; Suh, T; Chung, J

    2015-06-15

    Purpose: To verify the dose accuracy of Acuros XB (AXB) dose calculation algorithm at air-tissue interface using inhomogeneous phantom for 6-MV flattening filter-free (FFF) beams. Methods: An inhomogeneous phantom included air cavity was manufactured for verifying dose accuracy at the air-tissue interface. The phantom was composed with 1 and 3 cm thickness of air cavity. To evaluate the central axis doses (CAD) and dose profiles of the interface, the dose calculations were performed for 3 × 3 and 4 × 4 cm{sup 2} fields of 6 MV FFF beams with AAA and AXB in Eclipse treatment plainning system. Measurements in this region were performed with Gafchromic film. The root mean square errors (RMSE) were analyzed with calculated and measured dose profile. Dose profiles were divided into inner-dose profile (>80%) and penumbra (20% to 80%) region for evaluating RMSE. To quantify the distribution difference, gamma evaluation was used and determined the agreement with 3%/3mm criteria. Results: The percentage differences (%Diffs) between measured and calculated CAD in the interface, AXB shows more agreement than AAA. The %Diffs were increased with increasing the thickness of air cavity size and it is similar for both algorithms. In RMSEs of inner-profile, AXB was more accurate than AAA. The difference was up to 6 times due to overestimation by AAA. RMSEs of penumbra appeared to high difference for increasing the measurement depth. Gamma agreement also presented that the passing rates decreased in penumbra. Conclusion: This study demonstrated that the dose calculation with AXB shows more accurate than with AAA for the air-tissue interface. The 2D dose distributions with AXB for both inner-profile and penumbra showed better agreement than with AAA relative to variation of the measurement depths and air cavity sizes.

  15. Natural Air Purifier

    NASA Technical Reports Server (NTRS)

    1993-01-01

    NASA environmental research has led to a plant-based air filtering system. Dr. B.C. Wolverton, a former NASA engineer who developed a biological filtering system for space life support, served as a consultant to Terra Firma Environmental. The company is marketing the BioFilter, a natural air purifier that combines activated carbon and other filter media with living plants and microorganisms. The filter material traps and holds indoor pollutants; plant roots and microorganisms then convert the pollutants into food for the plant. Most non-flowering house plants will work. After pollutants have been removed, the cleansed air is returned to the room through slits in the planter. Terra Firma is currently developing a filter that will also disinfect the air.

  16. Removal of residual particulate matter from filter media

    SciTech Connect

    Almlie, Jay C; Miller, Stanley J

    2014-11-11

    A method for removing residual filter cakes that remain adhered to a filter after typical particulate removal methodologies have been employed, such as pulse-jet filter element cleaning, for all cleanable filters used for air pollution control, dust control, or powder control.

  17. Ozone Removal by Filters Containing Activated Carbon: A Pilot Study

    SciTech Connect

    Fisk, William; Spears, Mike; Sullivan, Douglas; Mendell, Mark

    2009-09-01

    This study evaluated the ozone removal performance of moderate-cost particle filters containing activated carbon when installed in a commercial building heating, ventilating, and air conditioning (HVAC) system. Filters containing 300 g of activated carbon per 0.09 m2 of filter face area were installed in two 'experimental' filter banks within an office building located in Sacramento, CA. The ozone removal performance of the filters was assessed through periodic measurements of ozone concentrations in the air upstream and downstream of the filters. Ozone concentrations were also measured upstream and downstream of a 'reference' filter bank containing filters without any activated carbon. The filter banks with prefilters containing activated carbon were removing 60percent to 70percent of the ozone 67 and 81 days after filter installation. In contrast, there was negligible ozone removal by the reference filter bank without activated carbon.

  18. Protective effects of an ethanol extract of Angelica keiskei against acetaminophen-induced hepatotoxicity in HepG2 and HepaRG cells

    PubMed Central

    Choi, Yoon-Hee; Lee, Hyun Sook; Chung, Cha-Kwon

    2017-01-01

    BACKGROUND/OBJECTIVE Although Angelica keiskei (AK) has widely been utilized for the purpose of general health improvement among Asian, its functionality and mechanism of action. The aim of this study was to determine the protective effect of ethanol extract of AK (AK-Ex) on acute hepatotoxicity induced by acetaminophen (AAP) in HepG2 human hepatocellular liver carcinoma cells and HepaRG human hepatic progenitor cells. MATERIALS/METHODS AK-Ex was prepared HepG2 and HepaRG cells were cultured with various concentrations and 30 mM AAP. The protective effects of AK-Ex against AAP-induced hepatotoxicity in HepG2 and HepaRG cells were evaluated using 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide, lactate dehydrogenase (LDH) assay, flow cytometry, and Western blotting. RESULTS AK-Ex, when administered prior to AAP, increased cell growth and decreased leakage of LDH in a dose-dependent manner in HepG2 and HepaRG cells against AAP-induced hepatotoxicity. AK-Ex increased the level of Bcl-2 and decreased the levels of Bax, Bok and Bik decreased the permeability of the mitochondrial membrane in HepG2 cells intoxicated with AAP. AK-Ex decreased the cleavage of poly (ADP-ribose) polymerase (PARP) and the activation of caspase-9, -7, and -3. CONCLUSIONS These results demonstrate that AK-Ex downregulates apoptosis via intrinsic and extrinsic pathways against AAP-induced hepatotoxicity. We suggest that AK could be a useful preventive agent against AAP-induced apoptosis in hepatocytes. PMID:28386382

  19. Reciprocal regulation of farnesoid X receptor α activity and hepatitis B virus replication in differentiated HepaRG cells and primary human hepatocytes.

    PubMed

    Radreau, Pauline; Porcherot, Marine; Ramière, Christophe; Mouzannar, Karim; Lotteau, Vincent; André, Patrice

    2016-09-01

    Hepatitis B virus (HBV) and bile salt metabolism seem tightly connected. HBV enters hepatocytes by binding to sodium taurocholate cotransporting polypeptide (NTCP), the genome of which contains 2 active farnesoid X receptor (FXR) α response elements that participate in HBV transcriptional activity. We investigated in differentiated HepaRG cells and in primary human hepatocytes (PHHs) effects of FXR activation on HBV replication and of infection on the FXR pathway. In HepaRG cells, FXR agonists (6-ethyl chenodeoxycholic acid and GW4064), but no antagonist, and an FXR-unrelated bile salt inhibited viral mRNA, DNA, and protein production (IC50, 0.1-0.5 μM) and reduced covalently closed circular DNA pool size. These effects were independent of the NTCP inhibitor cyclosporine-A, which suggests inhibition occurred at a postentry step. Similar results were obtained in PHHs with GW4064. Infection of these cells increased expression of FXR and modified expression of FXR-regulated genes SHP, APOA1, NTCP, CYP7A1, and CYP8B1 with a more pronounced effect in PHHs than in HepaRG cells. FXR agonists reversed all but one of the HBV-induced FXR gene profile modifications. HBV replication and FXR regulation seem to be interdependent, and altered bile salt metabolism homeostasis might contribute to the persistence of HBV infection.-Radreau, P., Porcherot, M., Ramière, C., Mouzannar, K., Lotteau, V., André, P. Reciprocal regulation of farnesoid X receptor α activity and hepatitis B virus replication in differentiated HepaRG cells and primary human hepatocytes.

  20. DETAIL OF FILTER DISCS ON DENVER FILTER IN CO91107. AS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL OF FILTER DISCS ON DENVER FILTER IN CO-91-107. AS DISCS SLOWLY ROTATE, VACUUM INSIDE DISCS ATTRACT SLURRY IN THE SUMP AND DEWATERS CONCENTRATE AS DISCS MOVE THROUGH AIR. FURTHER ROTATION PASSES A BAR TO SCRAPE OFF DRIED METAL CONCENTRATE, ASSISTED BY BLASTS OF COMPRESSED AIR. METAL CONCENTRATE READY FOR SHIPMENT TO SMELTER FALLS INTO BIN BELOW. EIMCO FILTERS OPERATE SIMILARLY. - Shenandoah-Dives Mill, 135 County Road 2, Silverton, San Juan County, CO

  1. Styrene removal from polluted air in one and two-liquid phase biotrickling filter: steady and transient-state performance and pressure drop control.

    PubMed

    Rene, Eldon R; Montes, María; Veiga, María C; Kennes, Christian

    2011-07-01

    A Sporothrix variecibatus-inoculated biotrickling filter (BTF) was examined for styrene removal, without and with the addition of silicone oil, at different empty bed residence times. The highest elimination capacities (ECs) were 172.8 (without silicone oil) and 670 g m(-3)h(-1) (with silicone oil), respectively, corresponding to a 4-fold improvement in presence of oil. The addition of silicone oil formed a well-coalesced emulsion of fungi and silicone oil, resulting in filter-bed clogging. Clogging prevention strategies adopted were; (i) lowering the volume ratio of silicone oil from 10% to 2% (v/v), and (ii) periodic increase in trickling rate of the medium from 50 to 190 mL min(-1). During shock-load experiments, the BTF with silicone oil (2% v/v) could withstand high styrene loads, of up to 1900 g m(-3)h(-1), when compared to the BTF without silicone oil (400 g m(-3)h(-1)).

  2. 14 CFR 23.1107 - Induction system filters.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Induction System... material particles in the induction air supply— (a) Each air filter must be capable of withstanding the... service and maintenance; and (b) Each air filter shall have a design feature to prevent material...

  3. 14 CFR 23.1107 - Induction system filters.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Induction System... material particles in the induction air supply— (a) Each air filter must be capable of withstanding the... service and maintenance; and (b) Each air filter shall have a design feature to prevent material...

  4. 14 CFR 23.1107 - Induction system filters.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Induction System... material particles in the induction air supply— (a) Each air filter must be capable of withstanding the... service and maintenance; and (b) Each air filter shall have a design feature to prevent material...

  5. 14 CFR 23.1107 - Induction system filters.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Induction System... material particles in the induction air supply— (a) Each air filter must be capable of withstanding the... service and maintenance; and (b) Each air filter shall have a design feature to prevent material...

  6. 14 CFR 23.1107 - Induction system filters.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Induction System... material particles in the induction air supply— (a) Each air filter must be capable of withstanding the... service and maintenance; and (b) Each air filter shall have a design feature to prevent material...

  7. Filter apparatus

    DOEpatents

    Kuban, Daniel P.; Singletary, B. Huston; Evans, John H.

    1984-01-01

    A plurality of holding tubes are respectively mounted in apertures in a partition plate fixed in a housing receiving gas contaminated with particulate material. A filter cartridge is removably held in each holding tube, and the cartridges and holding tubes are arranged so that gas passes through apertures therein and across the partition plate while particulate material is collected in the cartridges. Replacement filter cartridges are respectively held in holding canisters mounted on a support plate which can be secured to the aforesaid housing, and screws mounted on said canisters are arranged to push replacement cartridges into the cartridge holding tubes and thereby eject used cartridges therefrom.

  8. Filter apparatus

    DOEpatents

    Kuban, D.P.; Singletary, B.H.; Evans, J.H.

    A plurality of holding tubes are respectively mounted in apertures in a partition plate fixed in a housing receiving gas contaminated with particulate material. A filter cartridge is removably held in each holding tube, and the cartridges and holding tubes are arranged so that gas passes through apertures therein and across the the partition plate while particulate material is collected in the cartridges. Replacement filter cartridges are respectively held in holding canisters mounted on a support plate which can be secured to the aforesaid housing, and screws mounted on said canisters are arranged to push replacement cartridges into the cartridge holding tubes and thereby eject used cartridges therefrom.

  9. Sigma Filter

    NASA Technical Reports Server (NTRS)

    Balgovind, R. C.

    1985-01-01

    The GLA Fourth-Order model is needed to smooth the topography. This is to remove the Gibbs phenomenon. The Gibbs phenomenon occurs whenever we truncate a Fourier Series. The Sigma factors were introduced to reduce the Gibbs phenomenon. It is found that the smooth Fourier series is nothing but the original Fourier series with its coefficients multiplied by corresponding sigma factors. This operator can be applied many times to obtain high order sigma filtered field and is easily applicable using FFT. It is found that this filter is beneficial in deriving the topography.

  10. Water Filters

    NASA Technical Reports Server (NTRS)

    1988-01-01

    Seeking to find a more effective method of filtering potable water that was highly contaminated, Mike Pedersen, founder of Western Water International, learned that NASA had conducted extensive research in methods of purifying water on board manned spacecraft. The key is Aquaspace Compound, a proprietary WWI formula that scientifically blends various types of glandular activated charcoal with other active and inert ingredients. Aquaspace systems remove some substances; chlorine, by atomic adsorption, other types of organic chemicals by mechanical filtration and still others by catalytic reaction. Aquaspace filters are finding wide acceptance in industrial, commercial, residential and recreational applications in the U.S. and abroad.

  11. Filter Component Assessment

    SciTech Connect

    Alvin, M.A.; Lippert, T.E.; Diaz, E.S.; Smeltzer, E.E.

    1996-12-31

    Advanced particulate filtration systems are currently being developed at Westinghouse for use in both coal-fired Integrated Gasification Combined Cycle (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) systems. To date, Westinghouse has demonstrated 5855 hours of successful operation of first generation monolithic filter elements in PFBC applications when ash bridging or process thermal transient excursions are avoided. Alternate advanced monolithic and second generation fiber reinforced, filament wound and vacuum infiltrated filters are also being developed which are considered to have enhanced high temperature creep resistance, improved fracture toughness, or enhanced thermal shock characteristics, respectively. Mechanical and component fabrication improvements, as well as degradation mechanisms for each filter element have been identified by Westinghouse during exposure to simulated PFBC operating conditions and alkali-containing steam/air environments. Additional effort is currently being focused on determining the stability of the advanced monolithic high temperature creep resistant clay bonded silicon carbide (SiC) materials, alumina/mullite, and chemically vapor infiltrated (CVI) SiC materials during operation in the Westinghouse Advanced Particulate Filtration (W-APF) system at Foster Wheeler`s pressurized circulating fluidized-bed combustion (PCFBC) test facility in Karhula, Finland. Select advanced filter materials are being defined for additional long-term exposure in integrated gasification combined cycle (IGCC) gas streams. The results of these efforts are summarized in this paper. 6 refs., 7 figs., 11 tabs.

  12. Development, differentiation, and vascular components of subcutaneous and intrahepatic Hepa129 tumors in a mouse model of hepatocellular carcinoma.

    PubMed

    Robertson, Richard T; Gutierrez, Paula M; Baratta, Janie L; Thordarson, Kristoffer; Braslow, Joshua; Haynes, Sherry M; Longmuir, Kenneth J

    2016-04-01

    Tumor models in mice offer opportunities for understanding tumor formation and development of therapeutic treatments for hepatocellular carcinoma. In this study, subcutaneous or intra-hepatic Hepa129 tumors were established in C3H mice. Tumor growth was determined by daily measurements of subcutaneous tumors and post-mortem studies of subcutaneous and intrahepatic tumors. Administration of Edu was used to determine cell generation dates of tumor cells. Immunohistochemistry with antibodies directed at CD31 or CD34, and intravenous injection of labeled tomato lectin revealed tumor vasculature. Tissue sections also were processed for immunohistochemistry using a panel of antibodies to proteoglycans. Comparison of Edu labeled cells with immunoreactivity allowed determination of development and differentiation of tumor cells after cell generation. Subcutaneous and intrahepatic tumors displayed similar growth over 3 weeks. Immunohistochemistry showed strong labeling for glypican-3, 9BA12, and chondroitin sulfate of tumors in both loci, while normal liver was negative. Tumor regions containing Edu labeled cells did not show significant immunohistochemical labeling for the tumor markers until 2-3 days after Edu treatment; overlap of Edu labeled cells and immunohistochemically labeled tumor regions appeared to reach a maximum at 5 days after Edu treatment. Ectopic subcutaneous tumors displayed vascular ingrowth as the tumor cells expressed immunocytochemical markers; subcutaneous tumors displayed significantly more vascular elements than did intrahepatic tumors.

  13. Notch filter

    NASA Technical Reports Server (NTRS)

    Shelton, G. B. (Inventor)

    1977-01-01

    A notch filter for the selective attenuation of a narrow band of frequencies out of a larger band was developed. A helical resonator is connected to an input circuit and an output circuit through discrete and equal capacitors, and a resistor is connected between the input and the output circuits.

  14. Asthma Triggers and What to Do about Them

    MedlinePlus

    ... your child’s bedroom and consider putting a high-efficiency particulate air (HEPA) filter in their bedroom, removing ... water leakage. Control indoor humidity by using exhaust fans in the bathrooms and kitchen, and adding a ...

  15. Plasmonic filters.

    SciTech Connect

    Passmore, Brandon Scott; Shaner, Eric Arthur; Barrick, Todd A.

    2009-09-01

    Metal films perforated with subwavelength hole arrays have been show to demonstrate an effect known as Extraordinary Transmission (EOT). In EOT devices, optical transmission passbands arise that can have up to 90% transmission and a bandwidth that is only a few percent of the designed center wavelength. By placing a tunable dielectric in proximity to the EOT mesh, one can tune the center frequency of the passband. We have demonstrated over 1 micron of passive tuning in structures designed for an 11 micron center wavelength. If a suitable midwave (3-5 micron) tunable dielectric (perhaps BaTiO{sub 3}) were integrated with an EOT mesh designed for midwave operation, it is possible that a fast, voltage tunable, low temperature filter solution could be demonstrated with a several hundred nanometer passband. Such an element could, for example, replace certain components in a filter wheel solution.

  16. Water Filter

    NASA Technical Reports Server (NTRS)

    1982-01-01

    A compact, lightweight electrolytic water sterilizer available through Ambassador Marketing, generates silver ions in concentrations of 50 to 100 parts per billion in water flow system. The silver ions serve as an effective bactericide/deodorizer. Tap water passes through filtering element of silver that has been chemically plated onto activated carbon. The silver inhibits bacterial growth and the activated carbon removes objectionable tastes and odors caused by addition of chlorine and other chemicals in municipal water supply. The three models available are a kitchen unit, a "Tourister" unit for portable use while traveling and a refrigerator unit that attaches to the ice cube water line. A filter will treat 5,000 to 10,000 gallons of water.

  17. Eyeglass Filters

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Biomedical Optical Company of America's suntiger lenses eliminate more than 99% of harmful light wavelengths. NASA derived lenses make scenes more vivid in color and also increase the wearer's visual acuity. Distant objects, even on hazy days, appear crisp and clear; mountains seem closer, glare is greatly reduced, clouds stand out. Daytime use protects the retina from bleaching in bright light, thus improving night vision. Filtering helps prevent a variety of eye disorders, in particular cataracts and age related macular degeneration.

  18. FILTER FOR HIGH VELOCITY GAS STREAMS

    DOEpatents

    Heckman, R.A.; Warner, H.F.

    1963-11-01

    An air filter that is particularly useful in air-sampling rockets is presented. The filter comprises a cellulose fiber mat having an evenly disposed thin coating of stearic acid. Protective loose weave fabric covers are stitched to the front and back of the fiber mat, the stitching being in the form of a sine wave spiraled from the midpoint of the mat out to its periphery. (AEC)

  19. Modeling the effects of biomass accumulation on the performance of a biotrickling filter packed with PUF support for the alkaline biotreatment of dimethyl disulfide vapors in air.

    PubMed

    Arellano-García, Luis; Dorado, Antonio D; Morales-Guadarrama, Axayacatl; Sacristan, Emilio; Gamisans, Xavier; Revah, Sergio

    2015-01-01

    Excess biomass buildup in biotrickling filters leads to low performance. The effect of biomass accumulation in a biotrickling filter (BTF) packed with polyurethane foam (PUF) was assessed in terms of hydrodynamics and void space availability in a system treating dimethyl disulfide (DMDS) vapors with an alkaliphilic consortium. A sample of colonized support from a BTF having been operating for over a year was analyzed, and it was found that the BTF void bed fraction was reduced to almost half of that calculated initially without biomass. Liquid flow through the examined BTF yielded dispersion coefficient values of 0.30 and 0.72 m(2) h(-1), for clean or colonized PUF, respectively. 3D images of attached biomass obtained with magnetic resonance imaging allowed to calculate the superficial area and the biofilm volume percentage and depth as 650 m(2) m(-3), 35%, and 0.6 mm respectively. A simplified geometric approximation of the complex PUF structure was proposed using an orthogonal 3D mesh that predicted 600 m(2) m(-3) for the same biomass content. With this simplified model, it is suggested that the optimum biomass content would be around 20% of bed volume. The activity of the microorganisms was evaluated by respirometry and the kinetics represented with a Haldane equation type. Experimentally determined parameters were used in a mathematical model to simulate the DMDS elimination capacity (EC), and better description was found when the removal experimental data were matched with a model including liquid axial dispersion in contrast to an ideal plug flow model.

  20. Handbook on Air Cleaning Particulate Removal

    DTIC Science & Technology

    1952-09-01

    34orifice diameter 1220 3.4 (7) Hard, close grained shale dust containing 29% free silica; pro- duced in a drilling operation in a hard heading in a coal...Filter Equipped CFM. (American Air Filter Co.) with Motor Driven Vibrators (American Air Filter Co.) 34 HANDBOOK ON AIR CLEANING but efficiency is...Dry filters which are cleaned automati- P • " INLETcally are also available. They are vibrated , rather than shaken, at intervals to dis- lodge the dust

  1. Different Dose-Dependent Mechanisms Are Involved in Early Cyclosporine A-Induced Cholestatic Effects in HepaRG Cells

    PubMed Central

    Sharanek, Ahmad; Azzi, Pamela Bachour-El; Al-Attrache, Houssein; Savary, Camille C.; Humbert, Lydie; Rainteau, Dominique; Guguen-Guillouzo, Christiane; Guillouzo, André

    2014-01-01

    Mechanisms involved in drug-induced cholestasis in humans remain poorly understood. Although cyclosporine A (CsA) and tacrolimus (FK506) share similar immunosuppressive properties, only CsA is known to cause dose-dependent cholestasis. Here, we have investigated the mechanisms implicated in early cholestatic effects of CsA using the differentiated human HepaRG cell line. Inhibition of efflux and uptake of taurocholate was evidenced as early as 15 min and 1 h respectively after addition of 10μM CsA; it peaked at around 2 h and was reversible. These early effects were associated with generation of oxidative stress and deregulation of cPKC pathway. At higher CsA concentrations (≥50μM) alterations of efflux and uptake activities were enhanced and became irreversible, pericanalicular F-actin microfilaments were disorganized and bile canaliculi were constricted. These changes were associated with induction of endoplasmic reticulum stress that preceded generation of oxidative stress. Concentration-dependent changes were observed on total bile acid disposition, which were characterized by an increase and a decrease in culture medium and cells, respectively, after a 24-h treatment with CsA. Accordingly, genes encoding hepatobiliary transporters and bile acid synthesis enzymes were differently deregulated depending on CsA concentration. By contrast, FK506 induced limited effects only at 25–50μM and did not alter bile canaliculi. Our data demonstrate involvement of different concentration-dependent mechanisms in CsA-induced cholestasis and point out a critical role of endoplasmic reticulum stress in the occurrence of the major cholestatic features. PMID:24973091

  2. CRYSTAL FILTER TEST SET

    DTIC Science & Technology

    CRYSTAL FILTERS, *HIGH FREQUENCY, *RADIOFREQUENCY FILTERS, AMPLIFIERS, ELECTRIC POTENTIAL, FREQUENCY, IMPEDANCE MATCHING , INSTRUMENTATION, RADIOFREQUENCY, RADIOFREQUENCY AMPLIFIERS, TEST EQUIPMENT, TEST METHODS

  3. 17. VIEW OF AIR LOCK ENTRY DOOR. BANKS OF AIR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. VIEW OF AIR LOCK ENTRY DOOR. BANKS OF AIR FILTERS ARE VISIBLE TO THE SIDES OF THE DOORS. THE BUILDING WAS DIVIDED INTO ZONES BY AIRLOCK DOORS AND AIR FILTERS. AIR PRESSURE DIFFERENTIALS WERE MAINTAINED IN THE ZONES, SUCH THAT AIRFLOW WAS PROGRESSIVELY TOWARD AREAS WITH THE HIGHEST POTENTIAL FOR CONTAMINATION. (9/24/91) - Rocky Flats Plant, Plutonium Manufacturing Facility, North-central section of Plant, just south of Building 776/777, Golden, Jefferson County, CO

  4. Short-term versus long-term filter cassette sampling for viable fungi in indoor air: comparative performance of the Sartorius MD8 and the GSP sampler.

    PubMed

    Engelhart, Steffen; Exner, Martin

    2002-10-01

    Since the past decade, there is growing concern on the health implications of fungal exposure in indoor environments. Several methods are available for the measurement of airborne viable fungi, however, there is still a lack of standardization and comparability of these methods. The purpose of our field study was to apply the recommendations of the newly released technical standards TRBA 405 and 430 to the conditions of non-industrial indoor environments and to investigate the comparative performance of the two recommended filter cassette samplers (Sartorius MD8 and GSP) using the direct method. During two sampling phases (August to beginning of December 2000, and December 2000 to February 2001) a total of 360 short-term samples and 30 long-term samples were analyzed in parallel at 20 sampling days. Mean fungal CFUs varied from 2 x 10(1) to 3 x 10(2) CFU/m3, with the relative recovery of the GSP (vs. MD8) method being 1.00 (range, 0.89-1.14). We found a good correlation (Pearson's r = 0.95) between the MD8 and the GSP method. Both samplers showed good reproducibility, the coefficients of variation being 19.4% for the MD8, and 13.2% for the GSP sampler. Aspergillus and Penicillium (median proportions > 20% of the fungal CFUs, each) were the most prevalent indoor fungal genera during this season, followed by Wallemia (> 10%) and Cladosporium. The coefficients of variation for single genera ranged from 27% to 89%. We conclude that the recommendations of the technical standards TRBA 405 and 430 can efficiently be applied to survey fungal exposure under the conditions of non-industrial indoor environments. If short-term samples by using the MD8 are conducted for orientating purposes, at least two to three samples per sampling site are necessary in order to minimize intra-sampler variability (r > 0.95). Due to easy overloading of the small filter surface of the GSP at higher airborne spore concentrations, the more representative long-term sampling should preferably be

  5. Filtered or Unfiltered?

    ERIC Educational Resources Information Center

    Curry, Ann; Haycock, Ken

    2001-01-01

    Discusses results of a survey questionnaire of public and school libraries that investigated the use of Internet filtering software. Considers filter alternatives; reasons for filtering or not filtering; brand names; satisfaction with site blocking; satisfaction with the decision to install filter software; and guidelines for considering filters.…

  6. Preferential induction of the AhR gene battery in HepaRG cells after a single or repeated exposure to heterocyclic aromatic amines

    SciTech Connect

    Dumont, Julie Josse, Rozenn Lambert, Carine Antherieu, Sebastien Laurent, Veronique Loyer, Pascal Robin, Marie-Anne Guillouzo, Andre

    2010-11-15

    2-Amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) and 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx) are two of the most common heterocyclic aromatic amines (HAA) produced during cooking of meat, fish and poultry. Both HAA produce different tumor profiles in rodents and are suspected to be carcinogenic in humans. In order to better understand the molecular basis of HAA toxicity, we have analyzed gene expression profiles in the metabolically competent human HepaRG cells using pangenomic oligonucleotide microarrays, after either a single (24-h) or a repeated (28-day) exposure to 10 {mu}M PhIP or MeIQx. The most responsive genes to both HAA were downstream targets of the arylhydrocarbon receptor (AhR): CYP1A1 and CYP1A2 after both time points and CYP1B1 and ALDH3A1 after 28 days. Accordingly, CYP1A1/1A2 induction in HAA-treated HepaRG cells was prevented by chemical inhibition or small interference RNA-mediated down-regulation of the AhR. Consistently, HAA induced activity of the CYP1A1 promoter, which contains a consensus AhR-related xenobiotic-responsive element (XRE). In addition, several other genes exhibited both time-dependent and compound-specific expression changes with, however, a smaller magnitude than previously reported for the prototypical AhR target genes. These changes concerned genes mainly related to cell growth and proliferation, apoptosis, and cancer. In conclusion, these results identify the AhR gene battery as the preferential target of PhIP and MeIQx in HepaRG cells and further support the hypothesis that intake of HAA in diet might increase human cancer risk.

  7. The use of HepaRG and human hepatocyte data in predicting CYP induction drug-drug interactions via static equation and dynamic mechanistic modelling approaches.

    PubMed

    Grime, Ken; Ferguson, Douglas D; Riley, Robert J

    2010-12-01

    The method of predicting CYP induction drug-drug interactions (DDIs) from a relative induction score (RIS) calibration has been developed to provide a novel model facilitating predictions for any CYP-inducer substrate combination by inclusion of parameters such as the fraction of hepatic clearance mediated by a specific CYP and fraction of the dose escaping intestinal extraction. In vitro HepaRG CYP3A4 induction data were used as a basis for the approach and a large number of DDIs were well predicted. Primary human hepatocyte data were also used to make predictions, using the HepaRG calibration as a foundation. Similar predictive accuracy suggests that HepaRG and primary hepatocyte data can be used inter-changeably within the same laboratory. A comparison of this 'indirect' calibration method with a direct in vitro-in vivo scaling approach was made and investigations undertaken to define the most appropriate in vivo inducer concentration to use. Additionally, a reasonably effective prediction model based on F(2) (the concentration of inducer taken to increase the CYP mRNA 2-fold above background) was established. An accurate prediction for the CYP1A2-dependent omeprazole-caffeine interaction was also made, demonstrating that the methods are useful for the evaluation of DDIs from induction involving mechanisms other than PXR activation. Finally, a dynamic mechanistic model accounting for the simultaneous influence of CYP induction and reversible and irreversible CYP inhibition in both the liver and intestine was written to provide a prediction of the overall DDI when several interactions occur concurrently. The rationale for using the various models described, alongside commercially available prediction tools, at various stages of the drug discovery process is described.

  8. Evaluation of cytochrome P450 inductions by anti-epileptic drug oxcarbazepine, 10-hydroxyoxcarbazepine, and carbamazepine using human hepatocytes and HepaRG cells.

    PubMed

    Sugiyama, Ikuo; Murayama, Norie; Kuroki, Ayaka; Kota, Jagannath; Iwano, Shunsuke; Yamazaki, Hiroshi; Hirota, Takashi

    2016-09-01

    Anti-epileptic drug oxcarbazepine is structurally related to carbamazepine, but has reportedly different metabolic pathway. Auto-induction potentials of oxcarbazepine, its pharmacologically active metabolite 10-hydroxyoxcarbazepine and carbamazepine were evaluated by cytochrome P450 (CYP) 1A2, CYP2B6 and CYP3A4 mRNA levels and primary metabolic rates using human hepatocytes and HepaRG cells. For the CYP1A2 the induction potential determined as the fold change in mRNA levels was 7.2 (range: 2.3-11.5) and 10.0 (6.2-13.7) for oxcarbazepine and carbamazepine, respectively, while 10-hydroxyoxcarbazepine did not induce. The fold change in mRNA levels for CYP2B6 was 11.5 (3.2-19.3), 7.0 (2.5-10.8) and 14.8 (3.1-29.1) for oxcarbazepine, 10-hydroxyoxcarbazepine and carbamazepine, respectively. The fold change for CYP3A4 induction level by oxcarbazepine, 10-hydroxyoxcarbazepine and carbamazepine was 3.5 (1.2-7.4), 2.7 (0.8-5.7) and 8.3 (3.5-14.5), respectively. The data suggest lower induction potential of oxcarbazepine and 10-hydroxyoxcarbazepine relative to carbamazepine. The results in HepaRG cells showed similar trend as the human hepatocytes. After incubation for 72 h in hepatocytes and HepaRG cells, auto-induction was evident for only carbamazepine metabolism. The 10-keto group instead of double bond at C10 position is evidently a determinant factor for limited auto-induction of P450 enzymes by oxcarbazepine.

  9. Ceramic filters

    SciTech Connect

    Holmes, B.L.; Janney, M.A.

    1995-12-31

    Filters were formed from ceramic fibers, organic fibers, and a ceramic bond phase using a papermaking technique. The distribution of particulate ceramic bond phase was determined using a model silicon carbide system. As the ceramic fiber increased in length and diameter the distance between particles decreased. The calculated number of particles per area showed good agreement with the observed value. After firing, the papers were characterized using a biaxial load test. The strength of papers was proportional to the amount of bond phase included in the paper. All samples exhibited strain-tolerant behavior.

  10. One-stage biotrickling filter for the removal of a mixture of volatile pollutants from air: performance and microbial community analysis.

    PubMed

    López, M Estefanía; Rene, Eldon R; Malhautier, Luc; Rocher, Janick; Bayle, Sandrine; Veiga, María C; Kennes, Christian

    2013-06-01

    The biodegradation of gas-phase mixtures of methanol, α-pinene and H2S was examined in a biotrickling filter (BTF), inoculated with a microbial consortium composed of an autotrophic H2S-degrading culture, and pure strains of Candida boidinii, Rhodococcus erythropolis, and Ophiostoma stenoceras. The inlet concentrations of methanol, α-pinene and H2S varied from 0.05 to 3.3 gm(-3), 0.05 to 2.7 gm(-3), and 0.01 to 1.4 gm(-3), respectively, at empty bed residence times (EBRT) of either 38 or 26s. The maximum elimination capacities (ECmax) of the BTF were 302, 175, and 191 gm(-3)h(-1), with 100%, 67%, and >99% removal of methanol, α-pinene and H2S, respectively. The presence of methanol showed an antagonistic removal pattern for α-pinene, but the opposite did not occur. For α-pinene, inlet loading rates (ILRs) >150 gα-pinenem(-3)h(-1) affected its own removal in the BTF. The presence of H2S did not show any declining effect on the removal of both methanol and α-pinene.

  11. Rocket noise filtering system using digital filters

    NASA Technical Reports Server (NTRS)

    Mauritzen, David

    1990-01-01

    A set of digital filters is designed to filter rocket noise to various bandwidths. The filters are designed to have constant group delay and are implemented in software on a general purpose computer. The Parks-McClellan algorithm is used. Preliminary tests are performed to verify the design and implementation. An analog filter which was previously employed is also simulated.

  12. Microbial validation of vent filters.

    PubMed

    Robertson, J H; Frieben, W R

    1984-08-01

    The Upjohn Company uses filtration to remove microorganisms and particulates from air and other gases which may come in contact with sterile products. To validate the microbial retentivity of these filters, they were challenged with an aerosol of Bacillus subtilis var niger spores. An aerosol challenge was used because it more closely simulated the use for which these filters were designed. The test apparatus was constructed of autoclavable components using a jet-type nebulizer and heated air mixing tube. Characterization of the aerosol particle size distribution with a particle size analyzer demonstrated that 80% of the particles had a diameter of x 3.0 times;m and that the particles had a mean mass diameter of 1.9 times;m with a geometric standard deviation of 1.8 times;m. Studies conducted with aerosols of Bacillus subtilis var niger spores demonstrated that the test apparatus could recover ca. 50% of the spores that were aerosolized. Hydrophobic filters from various manufactures were challenged with an aerosol of at least 10(8) spores of Bacillus subtilis. All filters tested could retain at least 10(9) spores when physical integrity of the filter was verfield.

  13. Performance of three pilot-scale immobilized-cell biotrickling filters for removal of hydrogen sulfide from a contaminated air steam.

    PubMed

    Chen, Yiqing; Fan, Zhidong; Ma, Lixia; Yin, Juan; Luo, Man; Cai, Wangfeng

    2014-11-01

    Hydrogen sulfide (H2S) is a major malodorous compound emitted from wastewater treatment plants. In this study, the performance of three pilot-scale immobilized-cell biotrickling filters (BTFs) spacked with combinations of bamboo charcoal and ceramsite in different ratios was investigated in terms of H2S removal. Extensive tests were performed to determine the removal characteristics, pressure drops, metabolic products, and removal kinetics of the BTFs. The BTFs were operated in continuous mode at low loading rates varying from 0.59 to 5.00 g H2S m(-3) h(-1) with an empty bed retention time (EBRT) of 25 s. The removal efficiency (RE) for each BTF was >99% in the steady-state period, and high standards were met for the exhaust gas. It was found that a multilayer BTF had a slight advantage over a perfectly mixed BTF for the removal of H2S. Furthermore, an impressive amount >97% of the H2S was eliminated by 10% of packing materials near the inlet of the BTF. The modified Michaelis-Menten equation was adopted to describe the characteristics of the BTF, and K s and V m values for the BTF with pure bamboo charcoal packing material were 3.68 ppmv and 4.26 g H2S m(-3) h(-1), respectively. Both bamboo charcoal and ceramsite demonstrated good performance as packing materials in BTFs for the removal of H2S, and the results of this study could serve as a guide for further design and operation of industrial-scale systems.

  14. Performance of three pilot-scale immobilized-cell biotrickling filters for removal of hydrogen sulfide from a contaminated air steam

    PubMed Central

    Chen, Yiqing; Fan, Zhidong; Ma, Lixia; Yin, Juan; Luo, Man; Cai, Wangfeng

    2014-01-01

    Hydrogen sulfide (H2S) is a major malodorous compound emitted from wastewater treatment plants. In this study, the performance of three pilot-scale immobilized-cell biotrickling filters (BTFs) spacked with combinations of bamboo charcoal and ceramsite in different ratios was investigated in terms of H2S removal. Extensive tests were performed to determine the removal characteristics, pressure drops, metabolic products, and removal kinetics of the BTFs. The BTFs were operated in continuous mode at low loading rates varying from 0.59 to 5.00 g H2S m−3 h−1 with an empty bed retention time (EBRT) of 25 s. The removal efficiency (RE) for each BTF was >99% in the steady-state period, and high standards were met for the exhaust gas. It was found that a multilayer BTF had a slight advantage over a perfectly mixed BTF for the removal of H2S. Furthermore, an impressive amount >97% of the H2S was eliminated by 10% of packing materials near the inlet of the BTF. The modified Michaelis–Menten equation was adopted to describe the characteristics of the BTF, and Ks and Vm values for the BTF with pure bamboo charcoal packing material were 3.68 ppmv and 4.26 g H2S m−3 h−1, respectively. Both bamboo charcoal and ceramsite demonstrated good performance as packing materials in BTFs for the removal of H2S, and the results of this study could serve as a guide for further design and operation of industrial-scale systems. PMID:25313280

  15. Quantitative filter forensics for indoor particle sampling.

    PubMed

    Haaland, D; Siegel, J A

    2017-03-01

    Filter forensics is a promising indoor air investigation technique involving the analysis of dust which has collected on filters in central forced-air heating, ventilation, and air conditioning (HVAC) or portable systems to determine the presence of indoor particle-bound contaminants. In this study, we summarize past filter forensics research to explore what it reveals about the sampling technique and the indoor environment. There are 60 investigations in the literature that have used this sampling technique for a variety of biotic and abiotic contaminants. Many studies identified differences between contaminant concentrations in different buildings using this technique. Based on this literature review, we identified a lack of quantification as a gap in the past literature. Accordingly, we propose an approach to quantitatively link contaminants extracted from HVAC filter dust to time-averaged integrated air concentrations. This quantitative filter forensics approach has great potential to measure indoor air concentrations of a wide variety of particle-bound contaminants. Future studies directly comparing quantitative filter forensics to alternative sampling techniques are required to fully assess this approach, but analysis of past research suggests the enormous possibility of this approach.

  16. Breathing zone air sampler

    DOEpatents

    Tobin, John

    1989-01-01

    A sampling apparatus is provided which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

  17. Breathing zone air sampler

    SciTech Connect

    Tobin, J.

    1989-08-22

    A sampling apparatus is presented which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

  18. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - STANDARD FILTER CORPORATION PE16ZU FILTER SAMPLE

    EPA Science Inventory

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  19. Comprehensive Retrieval of Spatio-temporal Variations in Atmospheric Radionuclides just after the Fukushima Accident by Analyzing Filter-tapes of Operational Air Pollution Monitoring Stations in Eastern Japan

    NASA Astrophysics Data System (ADS)

    Tsuruta, Haruo; Oura, Yasuji; Ebihara, Mitsuru; Ohara, Toshimasa; Moriguchi, Yuichi; Nakajima, Teruyuki

    2016-04-01

    After the Fukushima Daiichi Nuclear Power Station (FD1NPS) accident on March 11, 2011, many datasets have been available of deposition density of radionuclides in soils in eastern Japan. By contrast, no time-series data of atmospheric radionuclides has been measured in the Fukushima prefecture (FP), although very limited data is available in the Tokyo metropolitan area (TMA) located more than 170 km southwest of the FD1NPS. As a result, atmospheric transport models simulating the atmospheric concentrations and surface deposition of radionuclides have large uncertainty, as well as the estimate of release rate of source terms and of internal exposure from inhalation. One year after the accident, we collected the used filter-tapes installed in Suspended Particulate Matter (SPM) monitors with beta-ray attenuation method operated by local governments in the air pollution monitoring network of eastern Japan. The SPM monitoring stations are mostly located in the urban and/or industrial area to measure the hourly mass concentration of SPM less than 10 μm in diameter for health effect due to atmospheric aerosols. By measuring radionuclides in SPM on the filter-tapes, we retrieved hourly atmospheric Cs-134 and Cs-137 concentrations during March 12-23, 2011, when atmospheric, aquatic, and terrestrial environments were seriously suffered in most of eastern Japan. Until now, we measured hourly radiocesium at around 100 SPM sites in the southern Tohoku region (ST) including the FP and in the TMA. By analysing the dataset, about 10 plumes/polluted air masses with Cs-137 concentrations higher than 10 Bq m-3 were found, and some plumes were newly detected in this study. And the spatio-temporal distributions of atmospheric Cs-137 were clearly shown for all the plumes. The east coast area of the FP where the FD1NPS was located in the centre was attacked several times by the plumes, and suffered the highest time-integrated Cs-137 concentration during the period among the ST and TMA

  20. Metabolomics analysis of the toxicity pathways of triphenyl phosphate in HepaRG cells and comparison to oxidative stress mechanisms caused by acetaminophen.

    PubMed

    Van den Eede, Nele; Cuykx, Matthias; Rodrigues, Robim M; Laukens, Kris; Neels, Hugo; Covaci, Adrian; Vanhaecke, Tamara

    2015-12-01

    Since the publication of REACH guidelines, the need for in vitro tools for toxicity testing has increased. We present here the development of a hepatotoxicity testing tool using human HepaRG cell cultures and metabolomics. HepaRG cells were exposed to either 4mM acetaminophen (APAP) as reference toxicant for oxidative stress or 50 μM triphenyl phosphate (TPHP) as toxicant with unknown toxicity pathways (TPs). After 72 h exposure, cells were subjected to quenching and liquid-liquid extraction which resulted in a polar and an apolar fraction. Analysis of fractions was performed by ultrahigh performance liquid chromatography-high resolution tandem mass spectrometry (UHPLC-QTOF-MS). Significantly up or down regulated metabolites were selected by univariate statistics prior to identification. In order to obtain robust and specific TP biomarkers, the experiment was also repeated using a different culture medium composition to assess which metabolites show consistent changes. Potential biomarkers belonging to different TPs were found for APAP and TPHP. For APAP, the biomarkers were related to a decrease in unsaturated phospholipids, and for TPHP to an accumulation of phosphoglycerolipids and increase of palmitoyl lysophosphatidylcholine. This first proof-of-concept opens new perspectives for the analysis of other (reference) toxicants with different TPs and it can be used to expand the in vitro tool for hepatotoxicity screening of various compounds.

  1. Histamine H2 receptor antagonism by T-593: studies on cAMP generation in Hepa cells expressing histamine H2 receptor.

    PubMed

    Tashiro, T; Ono, K; Watanabe, T; Inoie, M; Arai, H; Kimura, S; Kurokawa, K

    1999-07-01

    Histamine H2 receptor antagonism by T-593 was investigated in Hepa cells expressing canine histamine H2 receptors. T-593 inhibited generation of cAMP in Hepa cells stimulated by 10(-5) mol/l histamine with an IC50 value of 2.3 x 10(-6) mol/l, (S)-(-)-T-593, one of the enantiomers comprising racemic T-593, inhibited cAMP generation with an IC50 value of 6.1 x 10(-7) mol/l. On the other hand, the other enantiomer (R)-(+)-T-593 exhibited only a negligible effect. Incubation of the cell with (S)-(-)-T-593 for 60 min depressed the maximal response of the concentration-response curve of histamine with a nonparallel rightward shift. The slope of a Schild plot was 1.27. In contrast, (S)-(-)-T-593 caused a parallel rightward shift of the curve, with a Schild plot slope that did not significantly differ from unity, by treating the cells for 15 min. The H2 receptor-blocking action of (S)-(-)-T-593 remained almost unaffected after washing out the drug, whereas the effect of ranitidine was reversible after washing. These results suggest that T-593 possesses a time-dependent insurmountable antagonistic action against histamine H2 receptor. T-593 may interact with the histamine H2 receptor molecule in a slowly associable and dissociable manner.

  2. Suitability of air sampling locations downstream of bends and static mixing elements.

    PubMed

    McFarland, A R; Gupta, R; Anand, N K

    1999-12-01

    The revised standard for sampling effluent air from stacks and ducts of the nuclear industry places limits on the non-uniformity of velocity and contaminant profiles at the sampling location; namely, the coefficients of variation must not exceed 20% over an area that encompasses at least the center 2/3 of the cross sectional area. Tests were conducted to characterize the degree of mixing at downstream locations as affected by several types of flow disturbances, including 90 degree elbows and commercial static mixing devices. Flow straighteners were incorporated into the ducting upstream of the mixer to be tested to simulate the dampening of flow turbulence that might occur because of upstream HEPA filters. The coefficients of variation of velocity and tracer gas concentration measured in a straight tube at a distance of 3 diameters downstream from a 90 degree elbow were 17% and 69%, respectively. The mixing is impacted by the upstream flow turbulence. Without a flow straightener, the tracer gas concentration coefficient of variation was reduced to 33% at the 3-diameter location. The use of static mixing elements can greatly enhance the mixing process. A ring placed just downstream of a 90 degree elbow, which blocks the outer 56% of the cross sectional area, results in a coefficient of variation of 19% for tracer gas concentration at the 3-diameter location. Pressure loss across the elbow with the ring is about nine times that of the basic elbow. One of the commercially available static mixers provides coefficients of variation that are less than 10% for both velocity and tracer gas concentration at 4 diameters downstream from the mixer with a pressure loss that is only about 3.5 times as large as that of a 90 degree elbow.

  3. Gas sensors using single layer patterned interference optical filters

    NASA Astrophysics Data System (ADS)

    Rahmlow, Thomas D.; Gallagher, Kieran; Johnson, Robert L.

    2016-03-01

    A method for fabricating filters for fiber optic sensors is presented. The interference filter's construction is laid on it's side to allow for the use of air as the low refractive index material. Bandpass filters tuned to the absorption line of a trace gas can then be used as a sensitive means of detecting gas concentration. Complex filter designs can be fabricated in a single patterned layer. A CO2/CH4 gas sensor is presented as a design example.

  4. Tuning the target composition of amine-grafted CPO-27-Mg for capture of CO2 under post-combustion and air filtering conditions: a combined experimental and computational study.

    PubMed

    Bernini, M C; García Blanco, A A; Villarroel-Rocha, J; Fairen-Jimenez, D; Sapag, K; Ramirez-Pastor, A J; Narda, G E

    2015-11-21

    A computational and experimental screening of hypothetical and real compounds exhibiting different degrees of ethylenediamine grafted to the CPO-27-Mg or Mg-DOBDC skeleton is performed in order to determine the target composition that optimizes the CO2 adsorption properties under flue gas and air filtering conditions. On the basis of the [Mg2(dobdc)] formula, eighteen hypothetical models involving 15-100% of functionalization of the coordinatively unsaturated sites (CUS) were considered by means of Grand Canonical Monte Carlo simulations to evaluate the CO2 adsorption at 298 K. In addition, post-synthesis modification was applied to CPO-27-Mg leading to three kinds of samples exhibiting 15, 50, and 60% of CUS functionalization with ethylenediamine, named CPO-27-Mg-a, CPO-27-Mg-b and CPO-27-Mg-c. Compounds were characterized using elemental analysis, TGA, FTIR spectroscopy, PXRD and DSC. Finally, bare and functionalized CPO-27-Mg materials were evaluated using gas adsorption and microcalorimetry in the 0.001-1 bar range, which is pertinent for the mentioned applications. Valuable information related to design criteria for synthesis of tuned CO2 adsorbents is derived through this computational and experimental investigation.

  5. 40 CFR 721.10029 - Isocyanate compound, modified with methoxysilane (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... generically as isocyanate compound, modified with methoxysilane (PMN P-01-918) is subject to reporting under... absent), R100, or P100 filters; powered air-purifying respirator equipped with a tight-fitting full facepiece and High Efficiency Particulate Air (HEPA) filters; supplied-air respirator operated in...

  6. 40 CFR 721.10029 - Isocyanate compound, modified with methoxysilane (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... generically as isocyanate compound, modified with methoxysilane (PMN P-01-918) is subject to reporting under... absent), R100, or P100 filters; powered air-purifying respirator equipped with a tight-fitting full facepiece and High Efficiency Particulate Air (HEPA) filters; supplied-air respirator operated in...

  7. 40 CFR 721.10029 - Isocyanate compound, modified with methoxysilane (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... generically as isocyanate compound, modified with methoxysilane (PMN P-01-918) is subject to reporting under... absent), R100, or P100 filters; powered air-purifying respirator equipped with a tight-fitting full facepiece and High Efficiency Particulate Air (HEPA) filters; supplied-air respirator operated in...

  8. 40 CFR 721.10583 - Benzenamine, 4,4′-[1,3-phenylenebis(1-methylethylidene)]bis-.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...-certified air-purifying, tight-fitting half-face respirator equipped with N100 (if oil aerosols absent), R100, or P100 filters. (B) NIOSH-certified air-purifying, tight-fitting full-face respirator equipped... half-face or full-face) and HEPA filters. (E) NIOSH-certified supplied-air respirator operated...

  9. 40 CFR 721.10459 - Amino-substituted carbopolycycle (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... § 721.63(a)(4): NIOSH-certified air-purifying, tight-fitting, half-face respirator equipment with N100...-face respirator with N100 (if oil aerosols absent), R100, or P100 filters; NIOSH-certified powered air... half-face or full-face) and HEPA filters; or NIOSH-certified supplied-air respirator operated...

  10. 40 CFR 721.10171 - 1H-benz(e)indolium, 1,1,2,3-tetramethyl-, 4-methylbenzenesulfonic acid (1:1).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... with an APF of 10-25 meet the minimum requirements for § 721.63(a)(4): Air-purifying, tight-fitting respirator equipped with N100 (if oil aerosols absent), R100, or P100 filters (either half- or full-face... Particulate Air (HEPA) filters; powered air-purifying respirator equipped with a tight-fitting...

  11. 40 CFR 721.10057 - Dodecanedioic acid, 1, 12-dihydrazide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... respirators meet the minimum requirement for § 721.63(a)(4): Air-purifying, tight-fitting full-face respirator equipped with N100 (if oil aerosols absent), R100, or P100 filters; powered air-purifying respirator equipped with a tight-fitting full facepiece and High Efficiency Particulate Air (HEPA) filters;...

  12. 40 CFR 721.10057 - Dodecanedioic acid, 1, 12-dihydrazide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... respirators meet the minimum requirement for § 721.63(a)(4): Air-purifying, tight-fitting full-face respirator equipped with N100 (if oil aerosols absent), R100, or P100 filters; powered air-purifying respirator equipped with a tight-fitting full facepiece and High Efficiency Particulate Air (HEPA) filters;...

  13. 40 CFR 721.10171 - 1H-benz(e)indolium, 1,1,2,3-tetramethyl-, 4-methylbenzenesulfonic acid (1:1).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... with an APF of 10-25 meet the minimum requirements for § 721.63(a)(4): Air-purifying, tight-fitting respirator equipped with N100 (if oil aerosols absent), R100, or P100 filters (either half- or full-face... Particulate Air (HEPA) filters; powered air-purifying respirator equipped with a tight-fitting...

  14. 40 CFR 721.10171 - 1H-benz(e)indolium, 1,1,2,3-tetramethyl-, 4-methylbenzenesulfonic acid (1:1).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... with an APF of 10-25 meet the minimum requirements for § 721.63(a)(4): Air-purifying, tight-fitting respirator equipped with N100 (if oil aerosols absent), R100, or P100 filters (either half- or full-face... Particulate Air (HEPA) filters; powered air-purifying respirator equipped with a tight-fitting...

  15. 40 CFR 721.10171 - 1H-benz(e)indolium, 1,1,2,3-tetramethyl-, 4-methylbenzenesulfonic acid (1:1).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... with an APF of 10-25 meet the minimum requirements for § 721.63(a)(4): Air-purifying, tight-fitting respirator equipped with N100 (if oil aerosols absent), R100, or P100 filters (either half- or full-face... Particulate Air (HEPA) filters; powered air-purifying respirator equipped with a tight-fitting...

  16. 40 CFR 721.10171 - 1H-benz(e)indolium, 1,1,2,3-tetramethyl-, 4-methylbenzenesulfonic acid (1:1).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... with an APF of 10-25 meet the minimum requirements for § 721.63(a)(4): Air-purifying, tight-fitting respirator equipped with N100 (if oil aerosols absent), R100, or P100 filters (either half- or full-face... Particulate Air (HEPA) filters; powered air-purifying respirator equipped with a tight-fitting...

  17. NOVEL MICROWAVE FILTER DESIGN TECHNIQUES.

    DTIC Science & Technology

    ELECTROMAGNETIC WAVE FILTERS, MICROWAVE FREQUENCY, PHASE SHIFT CIRCUITS, BANDPASS FILTERS, TUNED CIRCUITS, NETWORKS, IMPEDANCE MATCHING , LOW PASS FILTERS, MULTIPLEXING, MICROWAVE EQUIPMENT, WAVEGUIDE FILTERS, WAVEGUIDE COUPLERS.

  18. Selecting Cells for Bioartificial Liver Devices and the Importance of a 3D Culture Environment: A Functional Comparison between the HepaRG and C3A Cell Lines

    PubMed Central

    van Wenum, Martien; Adam, Aziza A.A.; Hakvoort, Theodorus B.M.; Hendriks, Erik J.; Shevchenko, Valery; van Gulik, Thomas M.; Chamuleau, Robert A.F.M.; Hoekstra, Ruurdtje

    2016-01-01

    Recently, the first clinical trials on Bioartificial Livers (BALs) loaded with a proliferative human hepatocyte cell source have started. There are two cell lines that are currently in an advanced state of BAL development; HepaRG and HepG2/C3A. In this study we aimed to compare both cell lines on applicability in BALs and to identify possible strategies for further improvement. We tested both cell lines in monolayer- and BAL cultures on growth characteristics, hepatic differentiation, nitrogen-, carbohydrate-, amino acid- and xenobiotic metabolism. Interestingly, both cell lines adapted the hepatocyte phenotype more closely when cultured in BALs; e.g. monolayer cultures produced lactate, while BAL cultures showed diminished lactate production (C3A) or conversion to elimination (HepaRG), and urea cycle activity increased upon BAL culturing in both cell lines. HepaRG-BALs outperformed C3A-BALs on xenobiotic metabolism, ammonia elimination and lactate elimination, while protein synthesis was comparable. In BAL cultures of both cell lines ammonia elimination correlated positively with glutamine production and glutamate consumption, suggesting ammonia elimination was mainly driven by the balance between glutaminase and glutamine synthetase activity. Both cell lines lacked significant urea cycle activity and both required multiple culture weeks before reaching optimal differentiation in BALs. In conclusion, culturing in BALs enhanced hepatic functionality of both cell lines and from these, the HepaRG cells are the most promising proliferative cell source for BAL application. PMID:27489500

  19. Opsonisation of nanoparticles prepared from poly(β-hydroxybutyrate) and poly(trimethylene carbonate)-b-poly(malic acid) amphiphilic diblock copolymers: Impact on the in vitro cell uptake by primary human macrophages and HepaRG hepatoma cells.

    PubMed

    Vene, Elise; Barouti, Ghislaine; Jarnouen, Kathleen; Gicquel, Thomas; Rauch, Claudine; Ribault, Catherine; Guillaume, Sophie M; Cammas-Marion, Sandrine; Loyer, Pascal

    2016-11-20

    The present work reports the investigation of the biocompatibility, opsonisation and cell uptake by human primary macrophages and HepaRG cells of nanoparticles (NPs) formulated from poly(β-malic acid)-b-poly(β-hydroxybutyrate) (PMLA-b-PHB) and poly(β-malic acid)-b-poly(trimethylene carbonate) (PMLA-b-PTMC) diblock copolymers, namely PMLA800-b-PHB7300, PMLA4500-b-PHB4400, PMLA2500-b-PTMC2800 and PMLA4300-b-PTMC1400. NPs derived from PMLA-b-PHB and PMLA-b-PTMC do not trigger lactate dehydrogenase release and do not activate the secretion of pro-inflammatory cytokines demonstrating the excellent biocompatibility of these copolymers derived nano-objects. Using a protein adsorption assay, we demonstrate that the binding of plasma proteins is very low for PMLA-b-PHB-based nano-objects, and higher for those prepared from PMLA-b-PTMC copolymers. Moreover, a more efficient uptake by macrophages and HepaRG cells is observed for NPs formulated from PMLA-b-PHB copolymers compared to that of PMLA-b-PTMC-based NPs. Interestingly, the uptake in HepaRG cells of NPs formulated from PMLA800-b-PHB7300 is much higher than that of NPs based on PMLA4500-b-PHB4400. In addition, the cell internalization of PMLA800-b-PHB7300 based-NPs, probably through endocytosis, is strongly increased by serum pre-coating in HepaRG cells but not in macrophages. Together, these data strongly suggest that the binding of a specific subset of plasmatic proteins onto the PMLA800-b-PHB7300-based NPs favors the HepaRG cell uptake while reducing that of macrophages.

  20. Development of a DsRed-expressing HepaRG cell line for real-time monitoring of hepatocyte-like cell differentiation by fluorescence imaging, with application in screening of novel geometric microstructured cell growth substrates.

    PubMed

    Uta, Mihaela; Sima, Livia E; Hoffmann, Patrik; Dinca, Valentina; Branza-Nichita, Norica

    2017-03-01

    The bipotent nature of the HepaRG cell line is a unique property among human hepatoma-derived cells. Cell treatment with specific differentiation inducers results in a mixture of hepatocyte- and biliary-like cells, accompanied by upregulation of liver-specific proteins, drug metabolizing enzymes, transcription regulators, membrane receptors or innate immune response effectors. These features make the HepaRG cells a suitable and handy replacement for primary hepatocytes, to study hepatic functions in vitro. However, cell differentiation is a long, variable process, requiring special culture conditions, while the resulting mixed cell populations is usually a major drawback. This process can potentially be controlled by interface characteristics, such as substrate topography. To screen for such novel substrates, we have first developed a new HepaRG cell line, designated as HepaRG(DsRed), expressing the reporter gene DsRed. The fluorescent protein was expressed in hepatocyte- and not biliary-like cells, in a differentiation dependent-manner. We have further used replicated microstructured gradients of polydimethylsiloxane (PDMS) that allow three-dimensional manipulation in vitro, to monitor HepaRG(DsRed) differentiation in real time. We demonstrate that this approach enables the controlled assembly of viable hepatocyte-like cells for functional studies, which can be maintained in culture without loss of differentiation. The regulated expression of the DsRed reporter proved a valuable tool not only for rapid screening of novel cell growth substrates favoring cell differentiation, but also, to enrich the hepatocyte-like cell population by fluorescence-activated cell sorting to investigate liver-specific processes in vitro.

  1. In vitro evaluation of major in vivo drug metabolic pathways using primary human hepatocytes and HepaRG cells in suspension and a dynamic three-dimensional bioreactor system.

    PubMed

    Darnell, Malin; Ulvestad, Maria; Ellis, Ewa; Weidolf, Lars; Andersson, Tommy B

    2012-10-01

    Major human specific metabolites, not detected during in vivo and in vitro preclinical studies, may cause unexpected drug interactions and toxicity in human and delays in clinical programs. Thus, reliable preclinical tools for the detection of major human metabolites are of high importance. The aim of this study was to compare major drug metabolic pathways in HepaRG cells, a human hepatoma cell line, to fresh human hepatocytes, cryopreserved human hepatocytes, and human in vivo data. Furthermore, the maintenance of cytochrome P450 (P450) and UDP-glucuronosyltransferase (UGT) activities in a dynamic three-dimensional (3D) bioreactor were evaluated over time by using HepaRG cells and human hepatocytes. (14)C-diclofenac and a candidate from AstraZeneca's drug development program, (14)C-AZD6610, which are metabolized by P450 and UGT in vivo, were used as model substrates. The proportion of relevant biotransformation pathways of the investigated drug was clearly different in the various cell systems. The hydroxylation route was favored in primary human hepatocytes, whereas the glucuronidation route was favored in HepaRG cells. The human in vivo metabolite profile of AZD6610 was best represented by human hepatocytes, whereas all major diclofenac metabolites were detected in HepaRG cells. Moreover, the metabolite profiles in cryopreserved and fresh human hepatocytes were essentially the same. The liver bioreactor using both fresh human hepatocytes and HepaRG cells retained biotransformation capacity over 1 week. Thus, the incubation time can be increased from a few hours in suspension to several days in 3D cultures, which opens up for detection of metabolites from slowly metabolized drugs.

  2. Emergency sacrificial sealing method in filters, equipment, or systems

    SciTech Connect

    Brown, Erik P

    2014-09-30

    A system seals a filter or equipment component to a base and will continue to seal the filter or equipment component to the base in the event of hot air or fire. The system includes a first sealing material between the filter or equipment component and the base; and a second sealing material between the filter or equipment component and the base and proximate the first sealing material. The first sealing material and the second seal material are positioned relative to each other and relative to the filter or equipment component and the base to seal the filter or equipment component to the base and upon the event of fire the second sealing material will be activated and expand to continue to seal the filter or equipment component to the base in the event of hot air or fire.

  3. Emergency sacrificial sealing method in filters, equipment, or systems

    DOEpatents

    Brown, Erik P.

    2017-02-28

    A system seals a filter or equipment component to abase and will continue to seal the filter or equipment component to the base in the event of hot air or fire. The system includes a first sealing material between the filter or equipment component and the base; and a second sealing material between the filter or equipment component and the base and proximate the first sealing material. The first sealing material and the second seal material are positioned relative to each other and relative to the filter or equipment component and the base to seal the filter or equipment component to the base and upon the event of fire the second sealing material will be activated and expand to continue to seal the filter or equipment component to the base in the event of hot air or fire.

  4. Submicrometer particle removal indoors by a novel electrostatic precipitator with high clean air delivery rate, low ozone emissions, and carbon fiber ionizer.

    PubMed

    Kim, H-J; Han, B; Kim, Y-J; Oda, T; Won, H

    2013-10-01

    A novel positive-polarity electrostatic precipitator (ESP) was developed using an ionization stage (0.4 × 0.4 × 0.14 m(3) ) with 16 carbon fiber ionizers in each channel and a collection stage (0.4 × 0.4 × 0.21 m(3) ) with parallel metallic plates. The single-pass collection efficiency and clean air delivery rate (CADR) were measured by standard tests using KCl particles in 0.25-0.35 μm. Performance was determined using the Deutsch equation and established diffusion and field charging theories and also compared with the commercialized HEPA filter-type air cleaner. Experimental results showed that the single-pass collection efficiency of the ESP ranged from 50 to 95% and decreased with the flow rate (10-20 m(3) /min), but increased with the voltage applied to the ionizers (6 to 8 kV) and collection plates (-5 to -7 kV). The ESP with 18 m(3) /min achieved a CADR of 12.1 m(3) /min with a voltage of 8 kV applied to the ionization stage and with a voltage of -6 kV applied to the collection stage. The concentration of ozone in the test chamber (30.4 m(3) ), a maximum value of 5.4 ppb over 12 h of continuous operation, was much lower than the current indoor regulation (50 ppb).

  5. Airborne pathogens inside automobiles for domestic use: Assessing in-car air decontamination devices using Staphylococcus aureus as the challenge.

    PubMed

    Sattar, Syed A; Zargar, Bahram; Wright, Kathryn E; Rubino, Joseph R; Ijaz, M Khalid

    2017-04-07

    Family cars represent ∼74% of the yearly global output of motorized vehicles. With the life-expectancy of ∼8 decades in many countries, one spends >100 minutes daily inside the confined and often shared space of the car with exposure to a mix of potentially harmful microbes. Can commercial in-car air microbial decontamination devices mitigate the risk? Three such devices (designated as Device #s1-3) with HEPA filters were tested in the modified passenger cabin (3.25 m3) of a four-door sedan housed within a biosafety level 3 containment facility. Staphylococcus aureus (ATCC 6538) was suspended in a soil load to simulate the presence of body fluids and aerosolized into the car's cabin with a 6-jet Collison nebulizer. A muffin fan (80 mm X 80 mm, with an output of 0.17 cubic meter/minute) circulated the air inside. Plates (150 mm diam.) of Trypticase-soy agar, placed inside a programmable slit-to-agar sampler, were held at 36±1°C for 18-24 h and examined for CFU. The input dose of the test bacterium, its rate of biological decay and the log10 reductions by the test devices were analyzed. The arbitrarily-set performance criterion was the time in h a device took for a 3-log10 reduction in the level of airborne challenge bacterium. On average, the level of S. aureus challenge in the air varied between 4.2 log10CFU/m(3)and 5.5 log10 CFU/m(3), and its rate of biological decay was -0.0213±0.0021 log10CFU/m3/min. Devices #1-3, took 2.3, 1.5, and 9.7 h, respectively, to meet the performance criterion. While the experimental set-up was tested using S. aureus as an archetypical airborne pathogen, it can be readily adapted to test other types of pathogens and technologies.Importance: This is the first study designed to test the survival of airborne pathogens in the confined and shared space of a family automobile as well as to assess claims of devices marketed for in-car air decontamination. The basic experimental set-up and the test protocols reported are versatile

  6. Genome-wide Analysis of Human Constitutive Androstane Receptor (CAR) Transcriptome in Wild-type and CAR-knockout HepaRG cells

    PubMed Central

    Li, Daochuan; Mackowiak, Bryan; Brayman, Timothy G.; Mitchell, Michael; Zhang, Lei; Huang, Shiew-Mei; Wang, Hongbing

    2015-01-01

    The constitutive androstane receptor (CAR) modulates the transcription of numerous genes involving drug metabolism, energy homeostasis, and cell proliferation. Most functions of CAR however were defined from animal studies. Given the known species difference of CAR and the significant cross-talk between CAR and the pregnane X receptor (PXR), it is extremely difficult to decipher the exact role of human CAR (hCAR) in gene regulation, relying predominantly on pharmacological manipulations. Here, utilizing a newly generated hCAR-knockout (KO) HepaRG cell line, we carried out RNA-seq analysis of the global transcriptomes in wild-type (WT) and hCAR-KO HepaRG cells treated with CITCO, a selective hCAR agonist, phenobarbital (PB), a dual activator of hCAR and hPXR, or vehicle control. Real-time PCR assays in separate experiments were used to validate RNA-seq findings. Our results indicate that genes encoding drug-metabolizing enzymes are among the main clusters altered by both CITCO and PB. Specifically, CITCO significantly changed the expression of 135 genes in an hCAR-dependent manner, while PB altered the expression of 227 genes in WT cells of which 94 were simultaneously modulated in both cell lines reflecting dual effects of PB on hCAR/PXR. Notably, we found that many genes promoting cell proliferation and tumorigenesis were up-regulated in hCAR-KO cells, suggesting that hCAR may play an important role in cell growth that differs from mouse CAR. Together, our results reveal both novel and known targets of hCAR and support the role of hCAR in maintaining the homeostasis of metabolism and cell proliferation in the liver. PMID:26275810

  7. Genome-wide analysis of human constitutive androstane receptor (CAR) transcriptome in wild-type and CAR-knockout HepaRG cells.

    PubMed

    Li, Daochuan; Mackowiak, Bryan; Brayman, Timothy G; Mitchell, Michael; Zhang, Lei; Huang, Shiew-Mei; Wang, Hongbing

    2015-11-01

    The constitutive androstane receptor (CAR) modulates the transcription of numerous genes involving drug metabolism, energy homeostasis, and cell proliferation. Most functions of CAR however were defined from animal studies. Given the known species difference of CAR and the significant cross-talk between CAR and the pregnane X receptor (PXR), it is extremely difficult to decipher the exact role of human CAR (hCAR) in gene regulation, relying predominantly on pharmacological manipulations. Here, utilizing a newly generated hCAR-knockout (KO) HepaRG cell line, we carried out RNA-seq analysis of the global transcriptomes in wild-type (WT) and hCAR-KO HepaRG cells treated with CITCO, a selective hCAR agonist, phenobarbital (PB), a dual activator of hCAR and hPXR, or vehicle control. Real-time PCR assays in separate experiments were used to validate RNA-seq findings. Our results indicate that genes encoding drug-metabolizing enzymes are among the main clusters altered by both CITCO and PB. Specifically, CITCO significantly changed the expression of 135 genes in an hCAR-dependent manner, while PB altered the expression of 227 genes in WT cells of which 94 were simultaneously modulated in both cell lines reflecting dual effects of PB on hCAR/PXR. Notably, we found that many genes promoting cell proliferation and tumorigenesis were up-regulated in hCAR-KO cells, suggesting that hCAR may play an important role in cell growth that differs from mouse CAR. Together, our results reveal both novel and known targets of hCAR and support the role of hCAR in maintaining the homeostasis of metabolism and cell proliferation in the liver.

  8. Comparative evaluation of N-acetylcysteine and N-acetylcysteineamide in acetaminophen-induced hepatotoxicity in human hepatoma HepaRG cells

    PubMed Central

    Tobwala, Shakila; Khayyat, Ahdab; Fan, Weili

    2015-01-01

    Acetaminophen (N-acetyl-p-aminophenol, APAP) is one of the most widely used over-the-counter antipyretic analgesic medications. Despite being safe at therapeutic doses, an accidental or intentional overdose can result in severe hepatotoxicity; a leading cause of drug-induced liver failure in the U.S. Depletion of glutathione (GSH) is implicated as an initiating event in APAP-induced toxicity. N-acetylcysteine (NAC), a GSH precursor, is the only currently approved antidote for an APAP overdose. Unfortunately, fairly high doses and longer treatment times are required due to its poor bioavailability. In addition, oral and intravenous administration of NAC in a hospital setting are laborious and costly. Therefore, we studied the protective effects of N-acetylcysteineamide (NACA), a novel antioxidant, with higher bioavailability and compared it with NAC in APAP-induced hepatotoxicity in a human-relevant in vitro system, HepaRG. Our results indicated that exposure of HepaRG cells to APAP resulted in GSH depletion, reactive oxygen species (ROS) formation, increased lipid peroxidation, mitochondrial dysfunction (assessed by JC-1 fluorescence), and lactate dehydrogenase release. Both NAC and NACA protected against APAP-induced hepatotoxicity by restoring GSH levels, scavenging ROS, inhibiting lipid peroxidation, and preserving mitochondrial membrane potential. However, NACA was better than NAC at combating oxidative stress and protecting against APAP-induced damage. The higher efficiency of NACA in protecting cells against APAP-induced toxicity suggests that NACA can be developed into a promising therapeutic option for treatment of an APAP overdose. PMID:25245075

  9. Exposure to Fine Particulate Air Pollution Causes Vascular Insulin Resistance by Inducing Pulmonary Oxidative Stress

    PubMed Central

    Haberzettl, Petra; O’Toole, Timothy E.; Bhatnagar, Aruni; Conklin, Daniel J.

    2016-01-01

    Background: Epidemiological evidence suggests that exposure to ambient air fine particulate matter (PM2.5) increases the risk of developing type 2 diabetes and cardiovascular disease. However, the mechanisms underlying these effects of PM2.5 remain unclear. Objectives: We tested the hypothesis that PM2.5 exposure decreases vascular insulin sensitivity by inducing pulmonary oxidative stress. Methods: Mice fed control (10–13% kcal fat) and high-fat (60% kcal fat, HFD) diets, treated with 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPOL) or mice overexpressing lung-specific extracellular superoxide dismutase (ecSOD) were exposed to HEPA-filtered air or to concentrated PM2.5 (CAP) for 9 or 30 days, and changes in systemic and organ-specific insulin sensitivity and inflammation were measured. Results: In control diet–fed mice, exposure to CAP for 30 days decreased insulin-stimulated Akt phosphorylation in lung, heart, and aorta but not in skeletal muscle, adipose tissue, and liver and did not affect adiposity or systemic glucose tolerance. In HFD-fed mice, 30-day CAP exposure suppressed insulin-stimulated endothelial nitric oxide synthase (eNOS) phosphorylation in skeletal muscle and increased adipose tissue inflammation and systemic glucose intolerance. In control diet–fed mice, a 9-day CAP exposure was sufficient to suppress insulin-stimulated Akt and eNOS phosphorylation and to decrease IκBα (inhibitor of the transcription factor NF-κB levels in the aorta. Treatment with the antioxidant TEMPOL or lung-specific overexpression of ecSOD prevented CAP-induced vascular insulin resistance and inflammation. Conclusions: Short-term exposure to PM2.5 induces vascular insulin resistance and inflammation triggered by a mechanism involving pulmonary oxidative stress. Suppression of vascular insulin signaling by PM2.5 may accelerate the progression to systemic insulin resistance, particularly in the context of diet-induced obesity. Citation: Haberzettl P, O

  10. The use of filter media to determine filter cleanliness

    NASA Astrophysics Data System (ADS)

    Van Staden, S. J.; Haarhoff, J.

    It is general believed that a sand filter starts its life with new, perfectly clean media, which becomes gradually clogged with each filtration cycle, eventua