  1. Calibration of NASA Turbulent Air Motion Measurement System

    NASA Technical Reports Server (NTRS)

    Barrick, John D. W.; Ritter, John A.; Watson, Catherine E.; Wynkoop, Mark W.; Quinn, John K.; Norfolk, Daniel R.

    1996-01-01

    A turbulent air motion measurement system (TAMMS) was integrated onboard the Lockheed 188 Electra airplane (designated NASA 429) based at the Wallops Flight Facility in support of the NASA role in global tropospheric research. The system provides air motion and turbulence measurements from an airborne platform which is capable of sampling tropospheric and planetary boundary-layer conditions. TAMMS consists of a gust probe with free-rotating vanes mounted on a 3.7-m epoxy-graphite composite nose boom, a high-resolution inertial navigation system (INS), and data acquisition system. A variation of the tower flyby method augmented with radar tracking was implemented for the calibration of static pressure position error and air temperature probe. Additional flight calibration maneuvers were performed remote from the tower in homogeneous atmospheric conditions. System hardware and instrumentation are described and the calibration procedures discussed. Calibration and flight results are presented to illustrate the overall ability of the system to determine the three-component ambient wind fields during straight and level flight conditions.

  2. Calibrating airborne measurements of airspeed, pressure and temperature using a Doppler laser air-motion sensor

    NASA Astrophysics Data System (ADS)

    Cooper, W. A.; Spuler, S. M.; Spowart, M.; Lenschow, D. H.; Friesen, R. B.

    2014-09-01

    A new laser air-motion sensor measures the true airspeed with a standard uncertainty of less than 0.1 m s-1 and so reduces uncertainty in the measured component of the relative wind along the longitudinal axis of the aircraft to about the same level. The calculated pressure expected from that airspeed at the inlet of a pitot tube then provides a basis for calibrating the measurements of dynamic and static pressure, reducing standard uncertainty in those measurements to less than 0.3 hPa and the precision applicable to steady flight conditions to about 0.1 hPa. These improved measurements of pressure, combined with high-resolution measurements of geometric altitude from the global positioning system, then indicate (via integrations of the hydrostatic equation during climbs and descents) that the offset and uncertainty in temperature measurement for one research aircraft are +0.3 ± 0.3 °C. For airspeed, pressure and temperature, these are significant reductions in uncertainty vs. those obtained from calibrations using standard techniques. Finally, it is shown that although the initial calibration of the measured static and dynamic pressures requires a measured temperature, once calibrated these measured pressures and the measurement of airspeed from the new laser air-motion sensor provide a measurement of temperature that does not depend on any other temperature sensor.

  3. Calibrating airborne measurements of airspeed, pressure and temperature using a Doppler laser air-motion sensor

    NASA Astrophysics Data System (ADS)

    Cooper, W. A.; Spuler, S. M.; Spowart, M.; Lenschow, D. H.; Friesen, R. B.

    2014-03-01

    A new laser air-motion sensor measures the true airspeed with an uncertainty of less than 0.1 m s-1 (standard error) and so reduces uncertainty in the measured component of the relative wind along the longitudinal axis of the aircraft to about the same level. The calculated pressure expected from that airspeed at the inlet of a pitot tube then provides a basis for calibrating the measurements of dynamic and static pressure, reducing standard-error uncertainty in those measurements to less than 0.3 hPa and the precision applicable to steady flight conditions to about 0.1 hPa. These improved measurements of pressure, combined with high-resolution measurements of geometric altitude from the Global Positioning System, then indicate (via integrations of the hydrostatic equation during climbs and descents) that the offset and uncertainty in temperature measurement for one research aircraft are +0.3 ± 0.3 °C. For airspeed, pressure and temperature these are significant reductions in uncertainty vs. those obtained from calibrations using standard techniques. Finally, it is shown that the new laser air-motion sensor, combined with parametrized fits to correction factors for the measured dynamic and ambient pressure, provides a measurement of temperature that is independent of any other temperature sensor.

  4. Measuring mandibular motions

    NASA Technical Reports Server (NTRS)

    Dimeff, J.; Rositano, S.; Taylor, R. C.

    1977-01-01

    Mandibular motion along three axes is measured by three motion transducers on floating yoke that rests against mandible. System includes electronics to provide variety of outputs for data display and processing. Head frame is strapped to test subject's skull to provide fixed point of reference for transducers.

  5. Theory and operation of the Gould 32/27 programs ABLE-2A and EBLE for the tropospheric air motion measurement system

    NASA Technical Reports Server (NTRS)

    Butler, C.

    1986-01-01

    Software development for the Trospheric Air Motion Measurement Systems (TAMMS) is documented. In July/August the TAMMS was flown on the NASA/Goddard Flight Center Electra aircraft for 19 mission for the ABLE-2A (Amazon Boundary Layer Experiment) in Brazil. In December 1985, several flights were performed to assess the contamination and boundary layer of the Electra. Position data, flow angles, pressure transducer measurements were recorded. The programs written for the ABLE-2A were modified due to timing considerations for this particular program. The 3-step programs written for EBLE (Electra Boundary Layer Experiment) are described. Power up and log-on procedures are discussed. A few editing techniques are described for modification of the programs.

  6. Interferometric measurement of angular motion

    NASA Astrophysics Data System (ADS)

    Peña Arellano, Fabián Erasmo; Panjwani, Hasnain; Carbone, Ludovico; Speake, Clive C.

    2013-04-01

    This paper describes the design and realization of a homodyne polarization interferometer for measuring angular motion. The optical layout incorporates carefully designed cat's eye retroreflectors that maximize the measurable range of angular motion and facilitate initial alignment. The retroreflectors are optimized and numerically characterized in terms of defocus and spherical aberrations using Zemax software for optical design. The linearity of the measurement is then calculated in terms of the aberrations. The actual physical interferometer is realized as a compact device with optical components from stock and without relying on adjustable holders. Evaluation of its performance using a commercial autocollimator confirmed a reproducibility within 0.1%, a non-linearity of less than 1 ppm with respect to the autocollimator, an upper limit to its sensitivity of about 5 × 10-11 rad/sqrt{textrm {Hz}} from audioband down to 100 mHz and an angular measurement range of more than ±1°.

  7. Interferometric measurement of angular motion.

    PubMed

    Peña Arellano, Fabián Erasmo; Panjwani, Hasnain; Carbone, Ludovico; Speake, Clive C

    2013-04-01

    This paper describes the design and realization of a homodyne polarization interferometer for measuring angular motion. The optical layout incorporates carefully designed cat's eye retroreflectors that maximize the measurable range of angular motion and facilitate initial alignment. The retroreflectors are optimized and numerically characterized in terms of defocus and spherical aberrations using Zemax software for optical design. The linearity of the measurement is then calculated in terms of the aberrations. The actual physical interferometer is realized as a compact device with optical components from stock and without relying on adjustable holders. Evaluation of its performance using a commercial autocollimator confirmed a reproducibility within 0.1%, a non-linearity of less than 1 ppm with respect to the autocollimator, an upper limit to its sensitivity of about 5 × 10(-11) rad/Hz from audioband down to 100 mHz and an angular measurement range of more than ±1°.

  8. Motion of Air Bubbles in Water Subjected to Microgravity Accelerations

    NASA Technical Reports Server (NTRS)

    DeLombard, Richard; Kelly, Eric M.; Hrovat, Kenneth; Nelson, Emily S.; Pettit, Donald R.

    2006-01-01

    The International Space Station (ISS) serves as a platform for microgravity research for the foreseeable future. A microgravity environment is one in which the effects of gravity are drastically reduced which then allows physical experiments to be conducted without the over powering effects of gravity. During his 6-month stay on the ISS, astronaut Donald R. Pettit performed many informal/impromptu science experiments with available equipment. One such experiment focused on the motion of air bubbles in a rectangular container nearly filled with de-ionized water. Bubbles were introduced by shaking and then the container was secured in place for several hours while motion of the bubbles was recorded using time-lapse photography. This paper shows correlation between bubble motion and quasi-steady acceleration levels during one such experiment operation. The quasi-steady acceleration vectors were measured by the Microgravity Acceleration Measurement System (MAMS). Essentially linear motion was observed in the condition considered here. Dr. Pettit also created other conditions which produced linear and circulating motion, which are the subjects of further study. Initial observations of this bubble motion agree with calculations from many microgravity physical science experiments conducted on shuttle microgravity science missions. Many crystal-growth furnaces involve heavy metals and high temperatures in which undesired acceleration-driven convection during solidification can adversely affect the crystal. Presented in this paper will be results showing correlation between bubble motion and the quasi-steady acceleration vector.

  9. Motion of Air Bubbles in Water Subjected to Microgravity Accelerations

    NASA Technical Reports Server (NTRS)

    DeLombard, Richard; Kelly, Eric M.; Hrovar, Kenneth; Nelson, Emily S.; Pettit, Donald R.

    2004-01-01

    The International Space Station (ISS) serves as a platform for microgravity research for the foreseeable future. A microgravity environment is one in which the effects of gravity are drastically reduced which then allows physical experiments to be conducted without the overpowering effects of gravity. During his six month stay on the ISS, astronaut Donald R Pettit performed many informal/impromptu science experiments with available equipment. One such experiment focused on the motion of air bubbles in a rectangular container nearly filled with de-ionized water. Bubbles were introduced by shaking and the container was secured in place for several hours while motion of the bubbles were recorded using time-lapse photography. This paper shows correlation between bubble motion and quasi-steady acceleration levels during one such experiment operation. The quasi-steady acceleration vectors were measured by the Microgravity Acceleration Measurement System. Essentially linear motion was observed in the condition considered here. Dr. Pettit also created other conditions which produced linear and circulating motion, which are the subjects of further study. Initial observations of this bubble motion agree with calculations from many microgravity physical science experiments conducted on Shuttle microgravity science missions. Many crystal-growth furnaces involve heavy metals and high temperatures in which undesired acceleration-driven convection during solidification can adversely affect the crystal. Presented in this paper will be results showing correlation between bubble motion and the quasi-steady acceleration vector.

  10. Characteristics of vertical air motion in isolated convective clouds

    NASA Astrophysics Data System (ADS)

    Yang, Jing; Wang, Zhien; Heymsfield, Andrew J.; French, Jeffrey R.

    2016-08-01

    The vertical velocity and air mass flux in isolated convective clouds are statistically analyzed using aircraft in situ data collected from three field campaigns: High-Plains Cumulus (HiCu) conducted over the midlatitude High Plains, COnvective Precipitation Experiment (COPE) conducted in a midlatitude coastal area, and Ice in Clouds Experiment-Tropical (ICE-T) conducted over a tropical ocean. The results show that small-scale updrafts and downdrafts (< 500 m in diameter) are frequently observed in the three field campaigns, and they make important contributions to the total air mass flux. The probability density functions (PDFs) and profiles of the observed vertical velocity are provided. The PDFs are exponentially distributed. The updrafts generally strengthen with height. Relatively strong updrafts (> 20 m s-1) were sampled in COPE and ICE-T. The observed downdrafts are stronger in HiCu and COPE than in ICE-T. The PDFs of the air mass flux are exponentially distributed as well. The observed maximum air mass flux in updrafts is of the order 104 kg m-1 s-1. The observed air mass flux in the downdrafts is typically a few times smaller in magnitude than that in the updrafts. Since this study only deals with isolated convective clouds, and there are many limitations and sampling issues in aircraft in situ measurements, more observations are needed to better explore the vertical air motion in convective clouds.

  11. Remote air pollution measurement

    NASA Technical Reports Server (NTRS)

    Byer, R. L.

    1975-01-01

    This paper presents a discussion and comparison of the Raman method, the resonance and fluorescence backscatter method, long path absorption methods and the differential absorption method for remote air pollution measurement. A comparison of the above remote detection methods shows that the absorption methods offer the most sensitivity at the least required transmitted energy. Topographical absorption provides the advantage of a single ended measurement, and differential absorption offers the additional advantage of a fully depth resolved absorption measurement. Recent experimental results confirming the range and sensitivity of the methods are presented.

  12. Sensing Movement: Microsensors for Body Motion Measurement

    PubMed Central

    Zeng, Hansong; Zhao, Yi

    2011-01-01

    Recognition of body posture and motion is an important physiological function that can keep the body in balance. Man-made motion sensors have also been widely applied for a broad array of biomedical applications including diagnosis of balance disorders and evaluation of energy expenditure. This paper reviews the state-of-the-art sensing components utilized for body motion measurement. The anatomy and working principles of a natural body motion sensor, the human vestibular system, are first described. Various man-made inertial sensors are then elaborated based on their distinctive sensing mechanisms. In particular, both the conventional solid-state motion sensors and the emerging non solid-state motion sensors are depicted. With their lower cost and increased intelligence, man-made motion sensors are expected to play an increasingly important role in biomedical systems for basic research as well as clinical diagnostics. PMID:22346595

  13. Nocturnal wave-like air motion in forests

    NASA Astrophysics Data System (ADS)

    Hu, Xinzhang

    2001-09-01

    Although the wave-like air motion has been frequently observed near the treetops on clear nights, its flow structure and the nixing property remain largely unknown. A through knowledge of this type of motion will be beneficial to the measurement of the forest-atmosphere exchange of gases. The objectives of this dissertation are (1) to investigate the two-dimensional wave structure by analyzing the field observation; (2) to investigate the effect of the canopy drag on the wave dynamics with a two-layered linear wave model and a two-dimensional numerical wave model. The time-height analysis of the field observation illustrates that the wave-like motion bears resemblance to a Kelvin-Helmholtz (KH) wave. The temperature field and the polarization relation between the fluctuating velocities are similar to those of a KH wave at its growing and saturated stages. During the wave events, erratic flux-gradient relations have been found, sometimes associated with the statically unstable structure in the overturning waves. It is postulated that the wave-like motion has certain mixing ability. However, this mixing cannot be satisfactorily quantified by the current instrument setup. The two-layered linear model has been developed to investigate the effect of the canopy drag. It shows that, by modifying the growth rate, the canopy drag can either stabilize or destabilize the flow. A new type of instability has been found solely because of introducing the canopy drag to the otherwise stable background flow. Contrary to the common wisdom that the canopy drag will damp out any types of motion, the model indicates that forest canopies are actually favorable to the occurrence of the wave-like motion. Furthermore, the two-dimensional flow structure of the wave-like motion has been reproduced with a numerical model. With a simple turbulence closure scheme, the growth of a small disturbance to a finite-amplitude wave in a prescribed background has been computed. The computed flow

  14. Comparison of Motion Blur Measurement Methods

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.

    2008-01-01

    Motion blur is a significant display property for which accurate, valid measurement methods are needed. Recent measurements of a set of eight displays by a set of six measurement devices provide an opportunity to evaluate techniques of measurement and of the analysis of those measurements.

  15. Flight simulator platform motion and air transport pilot training.

    PubMed

    Lee, A T; Bussolari, S R

    1989-02-01

    The influence of flight simulator platform motion on pilot training and performance was examined in two studies utilizing a B-727-200 aircraft simulator. The simulator, located at Ames Research Center, is certified by the FAA for upgrade and transition training in air carrier operations. Subjective ratings and objective performance of experienced B-727 pilots did not reveal any reliable effects of wide variations in platform motion design. Motion platform variations did, however, affect the acquisition of control skill by pilots with no prior heavy aircraft flying experience. The effect was limited to pitch attitude control inputs during the early phase of landing training. Implications for the definition of platform motion requirements in air transport pilot training are discussed.

  16. Flight Simulator Platform Motion and Air Transport Pilot Training

    NASA Technical Reports Server (NTRS)

    Lee, Alfred T.; Bussolari, Steven R.

    1989-01-01

    The influence of flight simulator platform motion on pilot training and performance was examined In two studies utilizing a B-727-200 aircraft simulator. The simulator, located at Ames Research Center, Is certified by the FAA for upgrade and transition training in air carrier operations. Subjective ratings and objective performance of experienced B-727 pilots did not reveal any reliable effects of wide variations In platform motion de- sign. Motion platform variations did, however, affect the acquisition of control skill by pilots with no prior heavy aircraft flying experience. The effect was limited to pitch attitude control inputs during the early phase of landing training. Implications for the definition of platform motion requirements in air transport pilot training are discussed.

  17. Seismic switch for strong motion measurement

    DOEpatents

    Harben, P.E.; Rodgers, P.W.; Ewert, D.W.

    1995-05-30

    A seismic switching device is described that has an input signal from an existing microseismic station seismometer and a signal from a strong motion measuring instrument. The seismic switch monitors the signal level of the strong motion instrument and passes the seismometer signal to the station data telemetry and recording systems. When the strong motion instrument signal level exceeds a user set threshold level, the seismometer signal is switched out and the strong motion signal is passed to the telemetry system. The amount of time the strong motion signal is passed before switching back to the seismometer signal is user controlled between 1 and 15 seconds. If the threshold level is exceeded during a switch time period, the length of time is extended from that instant by one user set time period. 11 figs.

  18. Seismic switch for strong motion measurement

    DOEpatents

    Harben, Philip E.; Rodgers, Peter W.; Ewert, Daniel W.

    1995-01-01

    A seismic switching device that has an input signal from an existing microseismic station seismometer and a signal from a strong motion measuring instrument. The seismic switch monitors the signal level of the strong motion instrument and passes the seismometer signal to the station data telemetry and recording systems. When the strong motion instrument signal level exceeds a user set threshold level, the seismometer signal is switched out and the strong motion signal is passed to the telemetry system. The amount of time the strong motion signal is passed before switching back to the seismometer signal is user controlled between 1 and 15 seconds. If the threshold level is exceeded during a switch time period, the length of time is extended from that instant by one user set time period.

  19. Orientation-independent measures of ground motion

    USGS Publications Warehouse

    Boore, D.M.; Watson-Lamprey, Jennie; Abrahamson, N.A.

    2006-01-01

    The geometric mean of the response spectra for two orthogonal horizontal components of motion, commonly used as the response variable in predictions of strong ground motion, depends on the orientation of the sensors as installed in the field. This means that the measure of ground-motion intensity could differ for the same actual ground motion. This dependence on sensor orientation is most pronounced for strongly correlated motion (the extreme example being linearly polarized motion), such as often occurs at periods of 1 sec or longer. We propose two new measures of the geometric mean, GMRotDpp, and GMRotIpp, that are independent of the sensor orientations. Both are based on a set of geometric means computed from the as-recorded orthogonal horizontal motions rotated through all possible non-redundant rotation angles. GMRotDpp is determined as the ppth percentile of the set of geometric means for a given oscillator period. For example, GMRotDOO, GMRotD50, and GMRotD100 correspond to the minimum, median, and maximum values, respectively. The rotations that lead to GMRotDpp depend on period, whereas a single-period-independent rotation is used for GMRotIpp, the angle being chosen to minimize the spread of the rotation-dependent geometric mean (normalized by GMRotDpp) over the usable range of oscillator periods. GMRotI50 is the ground-motion intensity measure being used in the development of new ground-motion prediction equations by the Pacific Earthquake Engineering Center Next Generation Attenuation project. Comparisons with as-recorded geometric means for a large dataset show that the new measures are systematically larger than the geometric-mean response spectra using the as-recorded values of ground acceleration, but only by a small amount (less than 3%). The theoretical advantage of the new measures is that they remove sensor orientation as a contributor to aleatory uncertainty. Whether the reduction is of practical significance awaits detailed studies of large

  20. Simulation study of plane motion of air cushion vehicle

    NASA Astrophysics Data System (ADS)

    Zhao, Shu-Qin; Shi, Xiao-Cheng; Shi, Yi-Long; Bian, Xin-Qian

    2003-12-01

    This research is on horizontal plane motion equations of Air Cushion Vehicle (ACV) and its simulation. To investigate this, a lot of simulation study including ACV’s voyage and turning performance has been done. It was found that the voyage simulation results were accorded with ACV own characteristic and turning simulation results were accorded with USA ACV’s movement characteristic basically.

  1. Continuous Quantitative Measurements on a Linear Air Track

    ERIC Educational Resources Information Center

    Vogel, Eric

    1973-01-01

    Describes the construction and operational procedures of a spark-timing apparatus which is designed to record the back and forth motion of one or two carts on linear air tracks. Applications to measurements of velocity, acceleration, simple harmonic motion, and collision problems are illustrated. (CC)

  2. Semianalytic Theory of Motion for LEO Satellites Under Air Drag

    NASA Astrophysics Data System (ADS)

    Bezdek, A.

    The presented semianalytic theory focuses on the longterm evolution of the LEO satellites motion, with the TD/TD88 model of the total density as a key ingredient. Besides, the theory takes into account the main geopotential perturbations, for satellites with low eccentricity and/or inclination, nonsingular elements are used. An interesting feature of the theory is its computational speed (e.g. the 10-year propagation takes 5.5 s on a PC with Intel Celeron 1.7 GHz), while considering major physical conditions that strongly influence the thermospheric density (solar flux, geomagnetic activity, diurnal and seasonal variations, geographic latitude). The online calculation as well as the code are available on the Internet. The theory has been tested against the real world data of several spherical satellites. For the lifetime prediction accuracy estimate of the theory, we used a confidential interval based on the uncertainty in the drag coefficient CD, while taking the measured values of the solar flux and geomagnetic index. The modelled long-term behaviour of the orbital elements is in reasonably good agreement with the data, the computed lifetimes fall within the CD-induced confidential intervals, typical error in the mean lifetime prediction being a few percent. The tests showed that - provided one appropriately models the solar and geomagnetic activity - the theory may be used in the areas where one needs a quick orbital propagator for LEO objects influenced by air drag (mission planning, lifetime prediction, space debris dynamics). As an example, we will show the mission planning and the medium-term prediction of the motion for the MIMOSA satellite.

  3. Nonlinear optomechanical measurement of mechanical motion

    PubMed Central

    Brawley, G. A.; Vanner, M. R.; Larsen, P. E.; Schmid, S.; Boisen, A.; Bowen, W. P.

    2016-01-01

    Precision measurement of nonlinear observables is an important goal in all facets of quantum optics. This allows measurement-based non-classical state preparation, which has been applied to great success in various physical systems, and provides a route for quantum information processing with otherwise linear interactions. In cavity optomechanics much progress has been made using linear interactions and measurement, but observation of nonlinear mechanical degrees-of-freedom remains outstanding. Here we report the observation of displacement-squared thermal motion of a micro-mechanical resonator by exploiting the intrinsic nonlinearity of the radiation-pressure interaction. Using this measurement we generate bimodal mechanical states of motion with separations and feature sizes well below 100 pm. Future improvements to this approach will allow the preparation of quantum superposition states, which can be used to experimentally explore collapse models of the wavefunction and the potential for mechanical-resonator-based quantum information and metrology applications. PMID:26996234

  4. On the motion of air through the stratospheric polar vortex

    NASA Technical Reports Server (NTRS)

    Manney, G. L.; Zurek, R. W.; O'Neill, A.; Swinbank, R.

    1994-01-01

    Trajectory calculations using horizontal winds from the U.K. Meteorological Office data assimilation system and vertical velocities from a radiation calculation are used to simulate the three-dimensional motion of air through the stratospheric polar vortex for Northern Hemisphere (NH) and Southern Hemisphere (SH) winters since the launch of the Upper Atmosphere Research Satellite (UARS). Throughout the winter, air from the upper stratosphere moves poleward and descends into the middle stratosphere. In the SH lower to middle stratosphere, strongest descent occurs near the edge of the polar vortex, with that edge defined by mixing characteristics. The NH shows a similar pattern in late winter, but in early winter strongest descent is near the center of the vortex, except when wave activity is particularly strong. Strong barriers to latitudinal mixing exist above about 420 K throughout the winter. Below this, the polar night jet is weak in early winter, so air descending below that level mixes between polar and middle latitudes. In late winter, parcels descend less and the polar night jet moves downward, so there is less latitudinal mixing. The degree of mixing in the lower stratosphere thus depends strongly on the position and evolution of the polar night jet and on the amount of descent experienced by the air parcels; these characteristics show considerable interannual variability in both hemispheres. The computed trajectories provide a three-dimensional picture of air motion during the final warming. Large tongues of air are drawn off the vortex and stretched into increasingly long and narrow tongues extending into low latitudes. This vortex erosion process proceeds more rapidly in the NH than in he SH. In the lower stratosphere, the majority of air parcels remain confined within a lingering region of strong potential vorticity gradients into December in the SH and April in the NH, well after the vortex breaks up in the midstratosphere.

  5. Measuring mechanical motion with a single spin

    NASA Astrophysics Data System (ADS)

    Bennett, S. D.; Kolkowitz, S.; Unterreithmeier, Q. P.; Rabl, P.; Bleszynski Jayich, A. C.; Harris, J. G. E.; Lukin, M. D.

    2012-12-01

    We study theoretically the measurement of a mechanical oscillator using a single two-level system as a detector. In a recent experiment, we used a single electronic spin associated with a nitrogen-vacancy center in diamond to probe the thermal motion of a magnetized cantilever at room temperature (Kolkowitz et al 2012 Science 335 1603). Here, we present a detailed analysis of the sensitivity limits of this technique, as well as the possibility to measure the zero-point motion of the oscillator. Further, we discuss the issue of measurement backaction in sequential measurements and find that although backaction heating can occur, it does not prohibit the detection of zero-point motion. Throughout the paper, we focus on the experimental implementation of a nitrogen-vacancy center coupled to a magnetic cantilever; however, our results are applicable to a wide class of spin-oscillator systems. The implications for the preparation of nonclassical states of a mechanical oscillator are also discussed.

  6. Air pressure measurement

    NASA Technical Reports Server (NTRS)

    Ballard, H. N.

    1978-01-01

    The pressure measurement was made by a Model 830J Rosemont sensor which utilized the principle of a changing pressure to change correspondingly the capacitance of the pressure sensitive element. The sensor's range was stated to be from zero to 100 Torr (14 km); however, the sensor was not activated until an altitude of 20 km (41 Torr) was reached during the balloon ascent. The resolution of the sensor was specified by the manufacturer as infinitesimal; however, associated electronic and pressure readout systems limit the resolution to .044 Torr. Thus in the vicinity of an altitude of 30 km the pressure resolution corresponded to an altitude resolution of approximately 33 meters.

  7. Proper motion measurements of HH 224

    NASA Astrophysics Data System (ADS)

    Perez Rivera, Erika F.; Ybarra, Jason E.; Barsony, Mary; Phelps, Randy L.; Román-Zuñíga, Carlos; Tapia, Mauricio; José Downes, Juan

    2015-01-01

    We measured the proper motion of the components of Herbig-Haro object HH 224 embedded in the rho Ophiuchi cloud core using two epochs of [S II] imaging with a 17-year baseline. Our analysis finds the direction of HH 224N to be consistent with the other components of HH 224S suggesting HH 224S and HH 224N are part of the same flow. We discuss possible driving sources. We acknowledge partial support from PAPPIT-IN101813.

  8. Measuring Proper Motion of Barnard's Star

    NASA Astrophysics Data System (ADS)

    Wiechmann, Katrina; Michalik, Tom

    2009-03-01

    Stars of the night sky are generally considered to be fixed points, not changing noticeably over generations of observations. While most stars seem to appear in the same place year after year, some change location noticeably, the best example being Barnard's Star. Barnard's star is closer to Earth than any other star except Proxima Centauri. It also appears to move across the sky faster than any other star. This change in apparent location is caused by the movements of our Solar System and the motion of the star in question, and is known as proper motion. Using the astrometric capabilities of the MIRA software along with precise positional information for reference stars from the Tycho satellite star catalogue, the position of Barnard's star is computed relative to the reference stars. We calibrate a series of images of Barnard's Star taken in the Randolph College Observatory between 2001 and 2008 in order to independently determine the coordinates of Barnard's Star, revealing how these change over time. By measuring changes in the celestial coordinates, Right Ascension and Declination, we determine the proper motion of Barnard's star and compare this measurement to the accepted value of 10.25'' per year.

  9. Motion measurement for synthetic aperture radar

    SciTech Connect

    Doerry, Armin W.

    2015-01-01

    Synthetic Aperture Radar (SAR) measures radar soundings from a set of locations typically along the flight path of a radar platform vehicle. Optimal focusing requires precise knowledge of the sounding source locations in 3-D space with respect to the target scene. Even data driven focusing techniques (i.e. autofocus) requires some degree of initial fidelity in the measurements of the motion of the radar. These requirements may be quite stringent especially for fine resolution, long ranges, and low velocities. The principal instrument for measuring motion is typically an Inertial Measurement Unit (IMU), but these instruments have inherent limi ted precision and accuracy. The question is %22How good does an IMU need to be for a SAR across its performance space?%22 This report analytically relates IMU specifications to parametric requirements for SAR. - 4 - Acknowledgements Th e preparation of this report is the result of a n unfunded research and development activity . Although this report is an independent effort, it draws heavily from limited - release documentation generated under a CRADA with General Atomics - Aeronautical System, Inc. (GA - ASI), and under the Joint DoD/DOE Munitions Program Memorandum of Understanding. Sandia National Laboratories is a multi - program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of En ergy's National Nuclear Security Administration under contract AC04-94AL85000.

  10. Measurement, characterization, and prediction of strong ground motion

    USGS Publications Warehouse

    Joyner, William; Boore, David M.

    1988-01-01

    A number of predictive relationships derived from regression analysis of strong-motion data are available for horizontal peak acceleration, velocity, and response spectral values. Theoretical prediction of ground motion calls for stochastic source models because source heterogeneities control the amplitude of ground motion at most, if not all, frequencies of engineering interest. Theoretical methods have been developed for estimation of ground-motion parameters and simulation of ground-motion time series. These methods are particularly helpful for regions such, as eastern North America where strong-motion data are sparse. The authors survey the field, first reviewing developments in ground-motion measurement and data processing. The authors then consider the choice of parameters for characterizing strong ground motion and describe the wave-types involved in strong ground motion and the factors affecting ground-motion amplitudes. They conclude by describing methods for predicting ground motion.

  11. Vertical air motions derived from a descending radiosonde using a lightweight hard ball as the parachute

    NASA Astrophysics Data System (ADS)

    Chen, H.; Zhu, Y.; Zhang, J.; Xuan, Y.

    2013-09-01

    Knowledge of vertical air motions in the atmosphere is important for meteorological and climate studies due to its impact on clouds, precipitation and the vertical transport of air masses, heat, momentum, and composition. It is among the most difficult quantities to measure because of its small magnitude. In this study, a descending radiosonde technique has been developed to detect the vertical wind speed (VW) in the atmosphere. The system is composed of a radiosonde and a 0.5-m diameter hard ball made of plastic foam that acts as a parachute. The radiosonde hangs under the hard ball by a string which is then cut when the instrument is elevated into the upper troposphere by a balloon. The VW is derived from the difference between the observed radiosonde descent rate and the calculated radiosonde descent rate in still air based on fluid dynamics. Deduction of the appropriate drag coefficient for the radiosonde is facilitated by the symmetrical shape of the parachute. An intensive radiosonde launch experiment was held in northern China during the summer seasons of 2010 to 2012. This study uses radiosonde data collected during the campaign to retrieve the vertical air velocity within the radiosonde altitude-detecting range. In general, the VW ranges from -1 to 1 m s-1. Strong vertical air motion (~2 m s-1) is seen in a few radiosonde measurements. Although considerable uncertainties exist in measuring weak vertical air motions, a case study shows that there is reasonable agreement between retrievals of VW in the lower atmosphere from the radiosonde and a wind profiler radar located at the launch site.

  12. Fluctuations of total ozone and their relationship to stratospheric air motions

    NASA Technical Reports Server (NTRS)

    Salby, Murry L.; Callaghan, Patrick F.

    1993-01-01

    The origin of fluctuations of total ozone and the interactions that take place between the distribution of total ozone and the circulation of the troposphere are investigated on the basis of observations of total ozone from Nimbus 7 TOMS together with contemporaneous analyses of the circulation. It is shown that a sizable component of total ozone variability is explained by the quasi-columnar motion of air in the lower stratosphere. The development also suggests that in combination with isentropic analyses, total ozone measurements can provide a detailed picture of air motions in the lower stratosphere. Distributions of ozone column abundance and pressure on the 375-K isentropic surface for the Northern and Southern Hemispheres are illustrated.

  13. Air pollution measurements from satellites

    NASA Technical Reports Server (NTRS)

    Ludwig, C. B.; Griggs, M.; Malkmus, W.; Bartle, E. R.

    1973-01-01

    A study is presented on the remote sensing of gaseous and particulate air pollutants which is an extension of a previous report. Pollutants can be observed by either active or passive remote sensing systems. Calculations discussed herein indicate that tropospheric CO, CO2, SO2, NO2, NH3, HCHO, and CH4 can be measured by means of nadir looking passive systems. Additional species such as NO, HNO3, O3, and H2O may be measured in the stratosphere through a horizon experiment. A brief theoretical overview of resonance Raman scattering and resonance fluorescence is given. It is found that radiance measurements are most promising for general global applications, and that stratospheric aerosols may be measured using a sun occultation technique. The instrumentation requirements for both active and passive systems are examined and various instruments now under development are described.

  14. Ultrasonic bistatic Doppler sonar in air for personnel motion detection

    NASA Astrophysics Data System (ADS)

    Ekimov, Alexander; Hickey, Craig J.

    2012-06-01

    The National Center for Physical Acoustics (NCPA) at the University of Mississippi is working on the application of ultrasonic Doppler sonars in air for personnel motion detection. Two traditional Doppler sonar configurations, a monostatic and a bistatic, are being studied. In the monostatic configuration, the distance between the transmitter and the receiver is small. The proximity of the source to the receiver places a limitation on the system associated with the overloading of the receivers' input due to acoustic energy leakage from the transmitters' output. The maximum range of detection is therefore limited by the dynamic range of the acquisition system. In a bistatic Doppler ultrasonic sonar, the source and receiver are spaced apart and the acoustic energy along the direct path does not constrain the maximum acoustic power level output of the transmitter. In a monostatic configuration the acoustic signal suffers from beam spreading and natural absorption during propagation from the transmitter to the target and from the target back to the receiver. In a bistatic configuration the acoustic propagation is in one direction only and theoretically the detection distance can be twice the monostatic distance. For comparison the experiments of a human walking in a building hallway using the bistatic and monostaic Doppler sonars in air were conducted. The experimental results for human signatures from these Doppler sonars are presented and discussed.

  15. Evaluation of Three Sensor Types for Particle Motion Measurement.

    PubMed

    Martin, Bruce; Zeddies, David G; Gaudet, Briand; Richard, Joel

    2016-01-01

    All fish sense acoustic particle motion; some species also sense pressure. Concern over the effects of anthropogenic sounds is increasing the need to monitor acoustic particle motion. Particle motion can be measured directly using vector sensors or calculated from pressure gradients. This article compares three devices that measure particle motion: a three-axis accelerometer, a three-axis velocity sensor, and two 4-element hydrophone arrays. A series of sounds (constant-wave tones, white noise, and Ricker wavelets) were played from a fixed-position projector. The particle motion of sounds from imploding light bulbs was also measured.

  16. Evaluation of Three Sensor Types for Particle Motion Measurement.

    PubMed

    Martin, Bruce; Zeddies, David G; Gaudet, Briand; Richard, Joel

    2016-01-01

    All fish sense acoustic particle motion; some species also sense pressure. Concern over the effects of anthropogenic sounds is increasing the need to monitor acoustic particle motion. Particle motion can be measured directly using vector sensors or calculated from pressure gradients. This article compares three devices that measure particle motion: a three-axis accelerometer, a three-axis velocity sensor, and two 4-element hydrophone arrays. A series of sounds (constant-wave tones, white noise, and Ricker wavelets) were played from a fixed-position projector. The particle motion of sounds from imploding light bulbs was also measured. PMID:26611019

  17. Modeling the ascent of sounding balloons: derivation of the vertical air motion

    NASA Astrophysics Data System (ADS)

    Gallice, A.; Wienhold, F. G.; Hoyle, C. R.; Immler, F.; Peter, T.

    2011-06-01

    A new model to describe the ascent of sounding balloons in the troposphere and lower stratosphere (up to ~30-35 km altitude) is presented. Contrary to previous models, detailed account is taken of both the variation of the drag coefficient with altitude and the heat imbalance between the balloon and the atmosphere. To compensate for the lack of data on the drag coefficient of sounding balloons, a reference curve for the relationship between drag coefficient and Reynolds number is derived from a dataset of flights launched during the Lindenberg Upper Air Methods Intercomparisons (LUAMI) campaign. The transfer of heat from the surrounding air into the balloon is accounted for by solving the radial heat diffusion equation inside the balloon. The potential applications of the model include the forecast of the trajectory of sounding balloons, which can be used to increase the accuracy of the match technique, and the derivation of the air vertical velocity. The latter is obtained by subtracting the ascent rate of the balloon in still air calculated by the model from the actual ascent rate. This technique is shown to provide an approximation for the vertical air motion with an uncertainty error of 0.5 m s-1 in the troposphere and 0.2 m s-1 in the stratosphere. An example of extraction of the air vertical velocity is provided in this paper. We show that the air vertical velocities derived from the balloon soundings in this paper are in general agreement with small-scale atmospheric velocity fluctuations related to gravity waves, mechanical turbulence, or other small-scale air motions measured during the SUCCESS campaign (Subsonic Aircraft: Contrail and Cloud Effects Special Study) in the orographically unperturbed mid-latitude middle troposphere.

  18. Motion measurement of acoustically levitated object

    NASA Technical Reports Server (NTRS)

    Watkins, John L. (Inventor); Barmatz, Martin B. (Inventor)

    1993-01-01

    A system is described for determining motion of an object that is acoustically positioned in a standing wave field in a chamber. Sonic energy in the chamber is sensed, and variation in the amplitude of the sonic energy is detected, which is caused by linear motion, rotational motion, or drop shape oscillation of the object. Apparatus for detecting object motion can include a microphone coupled to the chamber and a low pass filter connected to the output of the microphone, which passes only frequencies below the frequency of sound produced by a transducer that maintains the acoustic standing wave field. Knowledge about object motion can be useful by itself, can be useful to determine surface tension, viscosity, and other information about the object, and can be useful to determine the pressure and other characteristics of the acoustic field.

  19. Motion capture for human motion measuring by using single camera with triangle markers

    NASA Astrophysics Data System (ADS)

    Takahashi, Hidenori; Tanaka, Takayuki; Kaneko, Shun'ichi

    2005-12-01

    This study aims to realize a motion capture for measuring 3D human motions by using single camera. Although motion capture by using multiple cameras is widely used in sports field, medical field, engineering field and so on, optical motion capture method with one camera is not established. In this paper, the authors achieved a 3D motion capture by using one camera, named as Mono-MoCap (MMC), on the basis of two calibration methods and triangle markers which each length of side is given. The camera calibration methods made 3D coordinates transformation parameter and a lens distortion parameter with Modified DLT method. The triangle markers enabled to calculate a coordinate value of a depth direction on a camera coordinate. Experiments of 3D position measurement by using the MMC on a measurement space of cubic 2 m on each side show an average error of measurement of a center of gravity of a triangle marker was less than 2 mm. As compared with conventional motion capture method by using multiple cameras, the MMC has enough accuracy for 3D measurement. Also, by putting a triangle marker on each human joint, the MMC was able to capture a walking motion, a standing-up motion and a bending and stretching motion. In addition, a method using a triangle marker together with conventional spherical markers was proposed. Finally, a method to estimate a position of a marker by measuring the velocity of the marker was proposed in order to improve the accuracy of MMC.

  20. Laser interferometric system for six-axis motion measurement

    SciTech Connect

    Zhang Zhipeng; Menq, C.-H.

    2007-08-15

    This article presents the development of a precision laser interferometric system, which is designed to achieve six-axis motion measurement for real-time applications. By combining the advantage of the interferometer with a retroreflector and that of the interferometer with a plane mirror reflector, the system is capable of simultaneously measuring large transverse motions along and large rotational motions about three orthogonal axes. Based on optical path analysis along with the designed kinematics of the system, a closed form relationship between the six-axis motion parameters of the object being measured and the readings of the six laser interferometers is established. It can be employed as a real-time motion sensor for various six-axis motion control stages. A prototype is implemented and integrated with a six-axis magnetic levitation stage to illustrate its resolution and measurement range.

  1. Micro air vehicle motion tracking and aerodynamic modeling

    NASA Astrophysics Data System (ADS)

    Uhlig, Daniel V.

    Aerodynamic performance of small-scale fixed-wing flight is not well understood, and flight data are needed to gain a better understanding of the aerodynamics of micro air vehicles (MAVs) flying at Reynolds numbers between 10,000 and 30,000. Experimental studies have shown the aerodynamic effects of low Reynolds number flow on wings and airfoils, but the amount of work that has been conducted is not extensive and mostly limited to tests in wind and water tunnels. In addition to wind and water tunnel testing, flight characteristics of aircraft can be gathered through flight testing. The small size and low weight of MAVs prevent the use of conventional on-board instrumentation systems, but motion tracking systems that use off-board triangulation can capture flight trajectories (position and attitude) of MAVs with minimal onboard instrumentation. Because captured motion trajectories include minute noise that depends on the aircraft size, the trajectory results were verified in this work using repeatability tests. From the captured glide trajectories, the aerodynamic characteristics of five unpowered aircraft were determined. Test results for the five MAVs showed the forces and moments acting on the aircraft throughout the test flights. In addition, the airspeed, angle of attack, and sideslip angle were also determined from the trajectories. Results for low angles of attack (less than approximately 20 deg) showed the lift, drag, and moment coefficients during nominal gliding flight. For the lift curve, the results showed a linear curve until stall that was generally less than finite wing predictions. The drag curve was well described by a polar. The moment coefficients during the gliding flights were used to determine longitudinal and lateral stability derivatives. The neutral point, weather-vane stability and the dihedral effect showed some variation with different trim speeds (different angles of attack). In the gliding flights, the aerodynamic characteristics

  2. Measuring Air Resistance in a Computerized Laboratory.

    ERIC Educational Resources Information Center

    Takahashi, Ken; Thompson, D.

    1999-01-01

    Presents an activity that involves dropping spherical party balloons onto a sonic motion sensor to show that the force associated with the air resistance is proportional to both the square of the velocity and the cross-sectional area of the balloon. (Author/WRM)

  3. Dynamic accuracy of inertial measurement units during simple pendulum motion.

    PubMed

    Brodie, M A; Walmsley, A; Page, W

    2008-06-01

    A motion measurement system based on inertial measurement units (IMUs) has been suggested as an alternative to contemporary video motion capture. This paper reports an investigation into the accuracy of IMUs in estimating 3D orientation during simple pendulum motion. The IMU vendor's (XSens Technologies) accuracy claim of 3 degrees root mean squared (RMS) error is tested. IMUs are integrated electronic devices that contain accelerometers, magnetometers and gyroscopes. The motion of a pendulum swing was measured using both IMUs and video motion capture as a reference. The IMU raw data were processed by the Kalman filter algorithm supplied by the vendor and a custom fusion algorithm developed by the authors. The IMU measurement of pendulum motion using the vendor's Kalman filter algorithm did not compare well with the video motion capture with a RMS error of between 8.5 degrees and 11.7 degrees depending on the length and type of pendulum swing. The maximum orientation error was greater than 30 degrees , occurring approximately eight seconds into the motion. The custom fusion algorithm estimation of orientation compared well with the video motion capture with a RMS error of between 0.8 degrees and 1.3 degrees . Future research should concentrate on developing a general purpose fusion algorithm and vendors of IMUs should provide details about the errors to be expected in different measurement situations, not just those in a 'best case' scenario. PMID:18568821

  4. Detection and measurement of retinal blood vessel pulsatile motion

    NASA Astrophysics Data System (ADS)

    Xiao, Di; Frost, Shaun; Vignarajan, Janardhan; An, Dong; Tay-Kearney, Mei-Ling; Kanagasingam, Yogi

    2016-03-01

    Retinal photography is a non-invasive and well-accepted clinical diagnosis of ocular diseases. Qualitative and quantitative assessment of retinal images is crucial in ocular diseases related clinical application. Pulsatile properties caused by cardiac rhythm, such as spontaneous venous pulsation (SVP) and pulsatile motion of small arterioles, can be visualized by dynamic retinal imaging techniques and provide clinical significance. In this paper, we aim at vessel pulsatile motion detection and measurement. We proposed a novel approach for pulsatile motion measurement of retinal blood vessels by applying retinal image registration, blood vessel detection and blood vessel motion detection and measurement on infrared retinal image sequences. The performance of the proposed methods was evaluated on 8 image sequences with 240 images. A preliminary result has demonstrated the good performance of the method for blood vessel pulsatile motion observation and measurement.

  5. Development of magnetically preloaded air bearings for a linear slide: active compensation of three degrees of freedom motion errors.

    PubMed

    Ro, Seung-Kook; Kim, Soohyun; Kwak, Yoonkeun; Park, Chun-Hong

    2008-03-01

    This article describes a linear air-bearing stage that uses active control to compensate for its motion errors. The active control is based on preloads generated by magnetic actuators, which were designed to generate nominal preloads for the air bearings using permanent magnets to maintain the desired stiffness while changing the air-bearing clearance by varying the magnetic flux generated by the current in electromagnetic coils. A single-axis linear stage with a linear motor and 240 mm of travel range was built to verify this design concept and used to test its performance. The motion of the table in three directions was controlled with four magnetic actuators driven by current amplifiers and a DSP (Digital Signal Processor)-based digital controller. The motion errors were measured using a laser interferometer combined with a two-probe method, and had 0.085 microm of repeatability for the straightness error. As a result of feed-forward active compensation, the errors were reduced from 1.09 to 0.11 microm for the vertical motion, from 9.42 to 0.18 arcsec for the pitch motion, and from 2.42 to 0.18 arcsec for the roll motion. PMID:18377049

  6. Unbiased measures of interocular transfer of motion adaptation.

    PubMed

    Vilidaité, Greta; Baker, Daniel H

    2015-01-01

    Numerous studies have measured the extent to which motion aftereffects transfer interocularly. However, many have done so using bias-prone methods, and studies rarely compare different types of motion directly. Here, we use a technique designed to reduce bias (Morgan, 2013, Journal of Vision, 13(8):26, 1-11) to estimate interocular transfer (IOT) for five types of motion: simple translational motion, expansion/contraction, rotation, spiral, and complex translational motion. We used both static and dynamic targets with subjects making binary judgments of perceived speed. Overall, the average IOT was 65%, consistent with previous studies (mean over 17 studies of 67% transfer). There was a main effect of motion type, with translational motion producing stronger IOT (mean: 86%) overall than any of the more complex varieties of motion (mean: 51%). This is inconsistent with the notion that IOT should be strongest for motion processed in extrastriate regions that are fully binocular. We conclude that adaptation is a complex phenomenon too poorly understood to make firm inferences about the binocular structure of motion systems. PMID:26422902

  7. Unbiased measures of interocular transfer of motion adaptation.

    PubMed

    Vilidaité, Greta; Baker, Daniel H

    2015-01-01

    Numerous studies have measured the extent to which motion aftereffects transfer interocularly. However, many have done so using bias-prone methods, and studies rarely compare different types of motion directly. Here, we use a technique designed to reduce bias (Morgan, 2013, Journal of Vision, 13(8):26, 1-11) to estimate interocular transfer (IOT) for five types of motion: simple translational motion, expansion/contraction, rotation, spiral, and complex translational motion. We used both static and dynamic targets with subjects making binary judgments of perceived speed. Overall, the average IOT was 65%, consistent with previous studies (mean over 17 studies of 67% transfer). There was a main effect of motion type, with translational motion producing stronger IOT (mean: 86%) overall than any of the more complex varieties of motion (mean: 51%). This is inconsistent with the notion that IOT should be strongest for motion processed in extrastriate regions that are fully binocular. We conclude that adaptation is a complex phenomenon too poorly understood to make firm inferences about the binocular structure of motion systems.

  8. Acoustic Measurement Of Periodic Motion Of Levitated Object

    NASA Technical Reports Server (NTRS)

    Watkins, John L.; Barmatz, Martin B.

    1992-01-01

    Some internal vibrations, oscillations in position, and rotations of acoustically levitated object measured by use of microphone already installed in typical levitation chamber for tuning chamber to resonance and monitoring operation. Levitating acoustic signal modulated by object motion of lower frequency. Amplitude modulation detected and analyzed spectrally to determine amplitudes and frequencies of motions.

  9. Vertical air motions over the Tropical Western Pacific for validating cloud resolving and regional models

    SciTech Connect

    Williams, Christopher R.

    2015-03-16

    The objective of this project was to estimate the vertical air motion using Doppler velocity spectra from two side-by-side vertically pointing radars. The retrieval technique was applied to two different sets of radars. This first set was 50- and 920-MHz vertically pointing radars near Darwin, Australia. The second set was 449-MHz and 2.8-GHz vertically pointing radars deployed at SGP for MC3E. The retrieval technique uses the longer wavelength radar (50 or 449 MHz) to observe both the vertical air motion and precipitation motion while the shorter wavelength radar (920 MHz or 2.8 GHz) observes just the precipitation motion. By analyzing their Doppler velocity spectra, the precipitation signal in the 920 MHz or 2.8 GHz radar is used to mask-out the precipitation signal in the 50 or 449 MHz radar spectra, leaving just the vertical air motion signal.

  10. Measuring Air-Ionizer Output

    NASA Technical Reports Server (NTRS)

    Lonborg, J. O.

    1985-01-01

    Test apparatus checks ion content of airstream from commercial air ionizer. Apparatus ensures ion output is sufficient to neutralize static charges in electronic assembly areas and concentrations of positive and negative ions are balanced.

  11. The influence of scales of atmospheric motion on air pollution over Portugal

    NASA Astrophysics Data System (ADS)

    Russo, Ana; Trigo, Ricardo; Mendes, Manuel; Jerez, Sonia; Gouveia, Célia Marina

    2014-05-01

    Air pollution is determined by the combination of different factors, namely, emissions, physical constrains, meteorology and chemical processes [1,2,3]. The relative importance of such factors is influenced by their interaction on diverse scales of atmospheric motion. Each scale depicts different meteorological conditions, which, when combined with the different air pollution sources and photochemistry, result in varying ambient concentrations [2]. Identifying the dominant scales of atmospheric motion over a given airshed can be of great importance for many applications such as air pollution and pollen dispersion or wind energy management [2]. Portugal has been affected by numerous air pollution episodes during the last decade. These episodes are often related to peak emissions from local industry or transport, but can also be associated to regional transport from other urban areas or to exceptional emission events, such as forest fires. This research aims to identify the scales of atmospheric motion which contribute to an increase of air pollution. A method is proposed for differentiating between the scales of atmospheric motion that can be applied on a daily basis from data collected at several wind-measuring sites in a given airshed and to reanalysis datasets. The method is based on the daily mean wind recirculation and the mean and standard deviation between sites. The determination of the thresholds between scales is performed empirically following the approach of Levy et al. [2] and also through a automatic statistical approach computed taking into account the tails of the distributions (e.g. 95% and 99% percentile) of the different wind samples. A comparison is made with two objective approaches: 1) daily synoptic classification for the same period over the region [4] and 2) a 3-D backward trajectory approach [5,6] for specific episodes. Furthermore, the outcomes are expected to support the Portuguese authorities on the implementation of strategies for a

  12. Intrinsic and extrinsic measurement for Brownian motion

    NASA Astrophysics Data System (ADS)

    Castro-Villarreal, Pavel

    2014-05-01

    Based upon the Smoluchowski equation on curved manifolds, three physical observables are considered for Brownian displacement, namely geodesic displacement s, Euclidean displacement δR, and projected displacement δR⊥. The Weingarten-Gauss equations are used to calculate the mean-square Euclidean displacements in the short-time regime. Our findings show that from an extrinsic point of view the geometry of the space affects the Brownian motion in such a way that the particle’s diffusion is decelerated, contrasting with the intrinsic point of view where dynamics is controlled by the sign of the Gaussian curvature (Castro-Villarreal, 2010 J. Stat. Mech. P08006). Furthermore, it is possible to give exact formulas for <δR> and <δR2> on spheres and minimal surfaces, which are valid for all values of time. In the latter case, surprisingly, Brownian motion corresponds to the usual diffusion in flat geometries, albeit minimal surfaces have non-zero Gaussian curvature. Finally, the two-dimensional case is emphasized due to its close relation to surface self-diffusion in fluid membranes.

  13. Modeling the ascent of sounding balloons: derivation of the vertical air motion

    NASA Astrophysics Data System (ADS)

    Gallice, A.; Wienhold, F. G.; Hoyle, C. R.; Immler, F.; Peter, T.

    2011-10-01

    A new model to describe the ascent of sounding balloons in the troposphere and lower stratosphere (up to ∼30-35 km altitude) is presented. Contrary to previous models, detailed account is taken of both the variation of the drag coefficient with altitude and the heat imbalance between the balloon and the atmosphere. To compensate for the lack of data on the drag coefficient of sounding balloons, a reference curve for the relationship between drag coefficient and Reynolds number is derived from a dataset of flights launched during the Lindenberg Upper Air Methods Intercomparisons (LUAMI) campaign. The transfer of heat from the surrounding air into the balloon is accounted for by solving the radial heat diffusion equation inside the balloon. In its present state, the model does not account for solar radiation, i.e. it is only able to describe the ascent of balloons during the night. It could however be adapted to also represent daytime soundings, with solar radiation modeled as a diffusive process. The potential applications of the model include the forecast of the trajectory of sounding balloons, which can be used to increase the accuracy of the match technique, and the derivation of the air vertical velocity. The latter is obtained by subtracting the ascent rate of the balloon in still air calculated by the model from the actual ascent rate. This technique is shown to provide an approximation for the vertical air motion with an uncertainty error of 0.5 m s-1 in the troposphere and 0.2 m s-1 in the stratosphere. An example of extraction of the air vertical velocity is provided in this paper. We show that the air vertical velocities derived from the balloon soundings in this paper are in general agreement with small-scale atmospheric velocity fluctuations related to gravity waves, mechanical turbulence, or other small-scale air motions measured during the SUCCESS campaign (Subsonic Aircraft: Contrail and Cloud Effects Special Study) in the orographically

  14. Effects of yaw and pitch motion on model attitude measurements

    NASA Technical Reports Server (NTRS)

    Tcheng, Ping; Tripp, John S.; Finley, Tom D.

    1995-01-01

    This report presents a theoretical analysis of the dynamic effects of angular motion in yaw and pitch on model attitude measurements in which inertial sensors were used during wind tunnel tests. A technique is developed to reduce the error caused by these effects. The analysis shows that a 20-to-1 reduction in model attitude measurement error caused by angular motion is possible with this technique.

  15. Bubble motion measurements during foam drainage and coarsening.

    PubMed

    Maurdev, G; Saint-Jalmes, A; Langevin, D

    2006-08-15

    We have studied bubble motion within a column of foam allowed to undergo free drainage. We have measured bubble motion upward with time and as a function of their initial positions. Depending on the gas used, which sets the coarsening and drainage rates, different bubble upward motion types have been identified (constant speed, acceleration or deceleration) and explained in relation with liquid downward flows. The proofs of the consistency between bubble upward motion and liquid downward flow are obtained both by comparing the bubble motion curves to the liquid drainage ones, and by comparing the time variations of the liquid fraction extracted from bubble motion to direct liquid fraction measurements by electrical conductimetry. The agreement between bubble position tracking and electrical conductivity shows in particular that it is possible to determine the drainage regime from such simple bubble motion measurements. This work also allowed us to demonstrate a special case of foam coarsening and expansion, occurring when the foam gas is less soluble than the outside one, caused by diffusion of this external gas into the foam. All these results allow us to build a picture of drainage and coarsening seen from the bubble point of view.

  16. Use of HART-II Measured Motion in CFD

    NASA Technical Reports Server (NTRS)

    Boyd, D. Douglas, Jr.

    2008-01-01

    This presentation examines the use of HART-II measured rotor blade motion in computational fluid dynamics (CFD). Historically, comprehensive analyses were used for input to acoustic calculations. These analyses focused on lifting line aerodynamics and beam models. However, there is a a need to evolve lifting line aerodynamics to first principles, notably the use of CFD instead of lifting line. The current analysis focuses on CFD and computational structural dynamics (CSD) coupling. Beam models are still very good (CSD is typically from comprehensive analysis), but generally CFD replaced aerodynamics in comprehensive analysis. This presentation examines both CFD and CSD individually and includes predictions using measured motion as well as predictions using measured motion versus coupled motion and calculations of "correct" airloads, noise and vibration.

  17. Technical Note: Simulation of 4DCT tumor motion measurement errors

    PubMed Central

    Dou, Tai H.; Thomas, David H.; O’Connell, Dylan; Bradley, Jeffrey D.; Lamb, James M.; Low, Daniel A.

    2015-01-01

    Purpose: To determine if and by how much the commercial 4DCT protocols under- and overestimate tumor breathing motion. Methods: 1D simulations were conducted that modeled a 16-slice CT scanner and tumors moving proportionally to breathing amplitude. External breathing surrogate traces of at least 5-min duration for 50 patients were used. Breathing trace amplitudes were converted to motion by relating the nominal tumor motion to the 90th percentile breathing amplitude, reflecting motion defined by the more recent 5DCT approach. Based on clinical low-pitch helical CT acquisition, the CT detector moved according to its velocity while the tumor moved according to the breathing trace. When the CT scanner overlapped the tumor, the overlapping slices were identified as having imaged the tumor. This process was repeated starting at successive 0.1 s time bin in the breathing trace until there was insufficient breathing trace to complete the simulation. The tumor size was subtracted from the distance between the most superior and inferior tumor positions to determine the measured tumor motion for that specific simulation. The effect of the scanning parameter variation was evaluated using two commercial 4DCT protocols with different pitch values. Because clinical 4DCT scan sessions would yield a single tumor motion displacement measurement for each patient, errors in the tumor motion measurement were considered systematic. The mean of largest 5% and smallest 5% of the measured motions was selected to identify over- and underdetermined motion amplitudes, respectively. The process was repeated for tumor motions of 1–4 cm in 1 cm increments and for tumor sizes of 1–4 cm in 1 cm increments. Results: In the examined patient cohort, simulation using pitch of 0.06 showed that 30% of the patients exhibited a 5% chance of mean breathing amplitude overestimations of 47%, while 30% showed a 5% chance of mean breathing amplitude underestimations of 36%; with a separate simulation

  18. Measuring nanometer, three-dimensional motions with light microscopy

    NASA Astrophysics Data System (ADS)

    Davis, Charles Quentin

    Computational motion analysis of images from a light microscope is used to explore mechanics in the microscopic worlds of cells and man-made micromachines. Images of a moving target are taken using a strobe light and a CCD camera attached to a microscope. Temporal sequences of stop-action images are recorded at multiple planes of focus to characterize three-dimensional motions. We demonstrate that motion resolution is limited by the motion detection algorithm. The largest source of error in gradient-based and matching algorithms is statistical bias. We present a new algorithm with errors that are typically smaller than 0.02 pixels. With this algorithm and our video microscopy system, we can measure motions of submicrometer targets with nanometer accuracy. The system has been used to study both hearing structures and man-made micromachines. Analysis of electrically- induced motions of a microfabricated accelerometer and a microfabricated angular velocity sensor allow visualization and quantification of complex modes of motion that limit the performance of these sensors. Pilot studies demonstrate that the system can also measure sound-induced motions of the human stapes, where it can resolve complex modes of motion thought to be important for loud sounds and for certain middle-ear pathologies. The system has also been used to measure mechanical deformations in the mouse tectorial membrane, a gelatinous inner-ear structure that has previously been a difficult target of study. Our major application has been the study of sound-induced motions of sensory cells and accessory structures in the ear of a lizard. Our results, while still preliminary, are the first direct measurements of sound-induced motions of hair bundles and their overlying tectorial membrane. They indicate that the tectorial membrane does not move as a rigid body but has significant shear throughout its thickness. Therefore, the relative motion between the tectorial membrane and the reticular lamina is

  19. Method for testing motion analysis laboratory measurement systems.

    PubMed

    Hakkarainen, Marko J; Bragge, Timo; Liikavainio, Tuomas; Arokoski, Jari; Karjalainen, Pasi A; Tarvainen, Mika

    2010-11-01

    This paper proposes a method for comparing data from accelerometers, optical based 3D motion capture systems, and force platforms (FPs) in the context of spatial and temporal differences. Testing method is based on the motion laboratory accreditation test (MLAT), which can be used to test FP and camera based motion capture components of a motion analysis laboratory. This study extends MLAT to include accelerometer data. Accelerometers were attached to a device similar to the MLAT rod. The elevation of the rod from the plane of the floor is computed and compared with the force platform vector orientation and the rod orientation obtained by optical motion capture system. Orientation of the test device is achieved by forming nonlinear equation group, which describes the components of the measured accelerations. Solution for this equation group is estimated by using the Gauss-Newton method. This expanded MLAT procedure can be used in the laboratory setting were either FP, camera based motion capture, or any other motion capture system is used along with accelerometer measurements.

  20. Measurements of Load Train Motion on a Stratospheric Balloon Flight

    NASA Technical Reports Server (NTRS)

    Gruner, Timothy D.; Olney, David J.; Russo, Angela M.

    2005-01-01

    Attitude measurements using gyros and magnetometers placed on a stratospheric balloon during a non-pointed test flight were used to observe the natural azimuth and elevation motions of a balloon/load train/gondola at an altitude of 36 km over a total flight time of 400 minutes. Time traces of the entire flight are presented. This flight, conducted under nominal atmospheric conditions, had significant motion about the azimuth. Some discussion on balloon disturbances is also included.

  1. The Effect of Solid Admixtures on the Velocity of Motion of a Free Dusty Air Jet

    NASA Technical Reports Server (NTRS)

    Chernov, A. P.

    1957-01-01

    In dusty air flows occurring in industrial practice in transport by air pressure of friable materials, in the drying, annealing, and so forth, of a pulverized solid mass in suspension, and in other processes, the concentration of solid particles usually has a magnitude of the order of 1 kg per 1 kg of air. At such a concentration, the ratio of the volume of the particles to the volume of the air is small (less than one-thousandth part). However, regardless of this, the presence of a solid admixture manifests itself in the rules for the velocity distribution of the air in a dusty air flow. As a result, the rules of velocity change are different for clean and for dusty air flows. The estimation of the influence of the admixture on the velocity of the motion of the flow presents a definitive interest. One of the attempts to estimate that influence on the axial velocity of a free axially symmetrical jet with admixtures was made by Abramovich. Abramovich assumed beforehand that the fine particles of the admixture in the jet are subject to the motion of the air (that is, that the velocity of the admixture is approximately equal to the local velocity of the air); he then took as the basis of his considerations, in solving the problem, the condition that the amount of motion of the two-phase jet must be constant.

  2. Air Quality Measurements for Science and Policy

    EPA Science Inventory

    Air quality measurements and the methods used to conduct them are vital to advancing our knowledge of the source-to-receptor-to-health effects continuum1-3. This information then forms the basis for evaluating and managing air quality to protect human health and welfa...

  3. Measurement of Air Pollutants in the Troposphere

    ERIC Educational Resources Information Center

    Clemitshaw, Kevin C.

    2011-01-01

    This article describes the principles, applications and performances of methods to measure gas-phase air pollutants that either utilise passive or active sampling with subsequent laboratory analysis or involve automated "in situ" sampling and analysis. It focuses on air pollutants that have adverse impacts on human health (nitrogen dioxide, carbon…

  4. AMAB: automated measurement and analysis of body motion.

    PubMed

    Poppe, Ronald; Van Der Zee, Sophie; Heylen, Dirk K J; Taylor, Paul J

    2014-09-01

    Technologies that measure human nonverbal behavior have existed for some time, and their use in the analysis of social behavior has become more popular following the development of sensor technologies that record full-body movement. However, a standardized methodology to efficiently represent and analyze full-body motion is absent. In this article, we present automated measurement and analysis of body motion (AMAB), a methodology for examining individual and interpersonal nonverbal behavior from the output of full-body motion tracking systems. We address the recording, screening, and normalization of the data, providing methods for standardizing the data across recording condition and across subject body sizes. We then propose a series of dependent measures to operationalize common research questions in psychological research. We present practical examples from several application areas to demonstrate the efficacy of our proposed method for full-body measurements and comparisons across time, space, body parts, and subjects.

  5. AMAB: automated measurement and analysis of body motion.

    PubMed

    Poppe, Ronald; Van Der Zee, Sophie; Heylen, Dirk K J; Taylor, Paul J

    2014-09-01

    Technologies that measure human nonverbal behavior have existed for some time, and their use in the analysis of social behavior has become more popular following the development of sensor technologies that record full-body movement. However, a standardized methodology to efficiently represent and analyze full-body motion is absent. In this article, we present automated measurement and analysis of body motion (AMAB), a methodology for examining individual and interpersonal nonverbal behavior from the output of full-body motion tracking systems. We address the recording, screening, and normalization of the data, providing methods for standardizing the data across recording condition and across subject body sizes. We then propose a series of dependent measures to operationalize common research questions in psychological research. We present practical examples from several application areas to demonstrate the efficacy of our proposed method for full-body measurements and comparisons across time, space, body parts, and subjects. PMID:24142835

  6. Experimental measurements of motion cue effects on STOL approach tasks

    NASA Technical Reports Server (NTRS)

    Ringland, R. F.; Stapleford, R. L.

    1972-01-01

    An experimental program to investigate the effects of motion cues on STOL approach is presented. The simulator used was the Six-Degrees-of-Freedom Motion Simulator (S.01) at Ames Research Center of NASA which has ?2.7 m travel longitudinally and laterally and ?2.5 m travel vertically. Three major experiments, characterized as tracking tasks, were conducted under fixed and moving base conditions: (1) A simulated IFR approach of the Augmentor Wing Jet STOL Research Aircraft (AWJSRA), (2) a simulated VFR task with the same aircraft, and (3) a single-axis task having only linear acceleration as the motion cue. Tracking performance was measured in terms of the variances of several motion variables, pilot vehicle describing functions, and pilot commentary.

  7. Super-Sharp Radio "Vision" Measures Galaxy's Motion in Space

    NASA Astrophysics Data System (ADS)

    2005-03-01

    Astronomers using the National Science Foundation's Very Long Baseline Array (VLBA) have measured the motion across the sky of a galaxy nearly 2.4 million light-years from Earth. While scientists have been measuring the motion of galaxies directly toward or away from Earth for decades, this is the first time that the transverse motion (called proper motion by astronomers) has been measured for a galaxy that is not a satellite of our own Milky Way Galaxy. M33 Radio/Optical Image of M33 CREDIT: NRAO/AUI/NSF, NOAO/AURA/NSF (Click on image for more files) An international scientific team analyzed VLBA observations made over two and a half years to detect minuscule shifts in the sky position of the spiral galaxy M33. Combined with previous measurements of the galaxy's motion toward Earth, the new data allowed the astronomers to calculate M33's movement in three dimensions for the first time. "A snail crawling on Mars would appear to be moving across the surface more than 100 times faster than the motion we measured for this galaxy," said Mark Reid, of the Harvard-Smithsonian Center for Astrophysics in Cambridge, MA. M33 is a satellite of the larger galaxy M31, the well-known Andromeda Galaxy that is the most distant object visible to the naked eye. Both are part of the Local Group of galaxies that includes the Milky Way. In addition to measuring the motion of M33 as a whole, the astronomers also were able to make a direct measurement of the spiral galaxy's rotation. Both measurements were made by observing the changes in position of giant clouds of molecules inside the galaxy. The water vapor in these clouds acts as a natural maser, strengthening, or amplifying, radio emission the same way that lasers amplify light emission. The natural masers acted as bright radio beacons whose movement could be tracked by the ultra-sharp radio "vision" of the VLBA. Reid and his colleagues plan to continue measuring M33's motion and also to make similar measurements of M31's motion

  8. Measurement of pulsatile motion with millisecond resolution by MRI.

    PubMed

    Souchon, Rémi; Gennisson, Jean-Luc; Tanter, Mickael; Salomir, Rares; Chapelon, Jean-Yves; Rouvière, Olivier

    2012-06-01

    We investigated a technique based on phase-contrast cine MRI combined with deconvolution of the phase shift waveforms to measure rapidly varying pulsatile motion waveforms. The technique does not require steady-state displacement during motion encoding. Simulations and experiments were performed in porcine liver samples in view of a specific application, namely the observation of transient displacements induced by acoustic radiation force. Simulations illustrate the advantages and shortcomings of the methods. For experimental validation, the waveforms were acquired with an ultrafast ultrasound scanner (Supersonic Imagine Aixplorer), and the rates of decay of the waveforms (relaxation time) were compared. With bipolar motion-encoding gradient of 8.4 ms, the method was able to measure displacement waveforms with a temporal resolution of 1 ms over a time course of 40 ms. Reasonable agreement was found between the rate of decay of the waveforms measured in ultrasound (2.8 ms) and in MRI (2.7-3.3 ms).

  9. Derivation and reliability of kinematic measures of sperm motion.

    PubMed

    Davis, R O; Siemers, R J

    1995-01-01

    Studies of sperm movement are relevant in the diagnosis of sperm function and in investigations of cellular biology. Such studies have been traditionally performed by analysing the kinematics of the flagellum or the head. Analysis of the flagellum can provide insights into the cell biological mechanisms responsible for the control of movement. However, the mathematical correspondence between head kinematics and flagellum kinematics is not unique. Therefore, it is not possible to use head kinematics to obtain detailed insights into cell mechanisms or physiology. The accuracy and precision of kinematic measurements are limited by a number of technical and biological factors. Therefore, the interpretation of kinematic data is dependent on a thorough understanding of the assumptions and conditions underlying the analysis. Evaluation of the reliability of kinematic measurements has suffered because no absolute standard for measurement has existed. The development and application of a new standard based on images which were simulated using the equations of motion is described. Because the kinematics of these images are known prior to empirical measurement, the performance of different methods can be determined absolutely. Some kinematic measures are unreliable because they are inappropriate analogues for engineering concepts. The development and use of appropriate engineering measures for the frequency and amplitude of sperm motion is also described. Some types of sperm motion cannot be analysed using kinematic measures (e.g. hyperactivated movement). The concept of the fractal dimension as a more accurate measurement for such motions is introduced. It is concluded that kinematic measurements of sperm motion can provide valuable information about cell biological mechanisms (in the case of the flagellum) and about general membrane and axoneme function (in the case of the head) when the measurements are made under the appropriate conditions, when standard techniques are

  10. Measuring Air Density in the Introductory Lab

    NASA Astrophysics Data System (ADS)

    Calzà, G.; Gratton, L. M.; López-Arias, T.; Oss, S.

    2010-03-01

    The measurement of the mass, or the density, of air can easily be done with very simple materials and offers many interesting phenomena for discussion—buoyancy and its effects being the most obvious but not the only one. Many interesting considerations can be done regarding the behavior of gases, the effect of the external conditions in the measurement, and the reason for the choice of the procedure, among others. One of the most widespread approaches makes use of rubber balloons. Such an approach can be misleading if attention is not paid to the effect of the buoyant force on the balloon, exerted by the surrounding air. Air is weightless in an environment full of it. While this fact can usually be neglected in daily, nontechnical weight measurements, it is not the case when we are interested in the weight of air itself. A sketch such as the one depicted in Fig. 1 is often presented in elementary science textbooks, as a demonstration that air has weight. A search of the Internet will reveal that this misleading approach is often presented as the simplest one for this kind of measurement at an elementary level and represents one among other common misconceptions that can be found in K-6 science textbooks as discussed, for instance, in Ref. 2. For a more detailed description of the flaws inherent to the measurement of air's weight with a rubber balloon, see Ref. 3. In this paper we will describe two procedures to measure the density of air: weighing a PET bottle and a vacuum rigid container. There are other interesting ways to estimate the weight of air; see, for instance, the experiment of Zhu and Se-yuen using carbon dioxide and Archimedes' principle.4 We emphasize the experimental implications and the physical reasons for the accuracy and conceptual correctness of each method. It is important not to undervalue the importance of both simplicity and reliability for any experimental measurement made in a didactic context.

  11. Vision System Measures Motions of Robot and External Objects

    NASA Technical Reports Server (NTRS)

    Talukder, Ashit; Matthies, Larry

    2008-01-01

    A prototype of an advanced robotic vision system both (1) measures its own motion with respect to a stationary background and (2) detects other moving objects and estimates their motions, all by use of visual cues. Like some prior robotic and other optoelectronic vision systems, this system is based partly on concepts of optical flow and visual odometry. Whereas prior optoelectronic visual-odometry systems have been limited to frame rates of no more than 1 Hz, a visual-odometry subsystem that is part of this system operates at a frame rate of 60 to 200 Hz, given optical-flow estimates. The overall system operates at an effective frame rate of 12 Hz. Moreover, unlike prior machine-vision systems for detecting motions of external objects, this system need not remain stationary: it can detect such motions while it is moving (even vibrating). The system includes a stereoscopic pair of cameras mounted on a moving robot. The outputs of the cameras are digitized, then processed to extract positions and velocities. The initial image-data-processing functions of this system are the same as those of some prior systems: Stereoscopy is used to compute three-dimensional (3D) positions for all pixels in the camera images. For each pixel of each image, optical flow between successive image frames is used to compute the two-dimensional (2D) apparent relative translational motion of the point transverse to the line of sight of the camera. The challenge in designing this system was to provide for utilization of the 3D information from stereoscopy in conjunction with the 2D information from optical flow to distinguish between motion of the camera pair and motions of external objects, compute the motion of the camera pair in all six degrees of translational and rotational freedom, and robustly estimate the motions of external objects, all in real time. To meet this challenge, the system is designed to perform the following image-data-processing functions: The visual-odometry subsystem

  12. Measurement of toxic and related air pollutants

    SciTech Connect

    Jayanty, R.K.M.; Gay, B.W. Jr.

    1990-12-01

    A joint conference for the fifth straight year cosponsored by the Air and Waste Management Association's EM-3, EM-4, and ITF-2 technical committees, and the Atmospheric Research and Exposure Assessment Laboratory (AREAL) of the US Environmental Protection Agency, was held in Raleigh, North Carolina, May 1-4, 1990. The technical program consisted of 187 presentations, held in 20 technical sessions, on recent advances in the measurement and monitoring of toxic and related pollutants found in ambient and source atmospheres. Covering a wide range of measurement topics and supported by 66 exhibitors of instrumentation and consulting services, the symposium was attended by more than 850 professionals from the US and other countries. This overview highlights a selection of the technical presentations. A synopsis of the keynote address to the symposium is also included. Presentations include: (1) radon, (2) atmospheric chemistry and fate of toxic pollutants, (3) supercritical fluid extraction, (4) acidic deposition, (5) determination of polar and volatile organic pollutants in ambient air, (6) Delaware Superfund innovative technology evaluation (SITE) study, (7) mobile sources emissions characterization, (8) Superfund site air monitoring, (9) exposure assessment, (10) chemometrics and environmental data analysis, (11) nicotine in environmental tobacco smoke, (12) source monitoring, (13) effects of air toxics on plants, (14) measurement of volatile organic pollutants, (15) general, (16) air pollution dispersion modeling, (17) measurement of hazardous waste emissions, (18) measurement of indoor toxic air contaminants, and (19) environmental quality assurance.

  13. Air volume measurement of 'Braeburn' apple fruit.

    PubMed

    Drazeta, Lazar; Lang, Alexander; Hall, Alistair J; Volz, Richard K; Jameson, Paula E

    2004-05-01

    The radial disposition of air in the flesh of fruit of Malus domestica Borkh., cv 'Braeburn' was investigated using a gravimetric technique based on Archimedes' principle. Intercellular air volume was measured by weighing a small tissue sample under water before and after vacuum infiltration to remove the air. In a separate procedure, the volume of the same sample was measured by recording the buoyant upthrust experienced by it when fully immersed in water. The method underestimates tissue air volume due to a slight invasion of the intercellular air spaces around the edges of the sample when it is immersed in water. To correct for this error, an adjustment factor was made based upon an analysis of a series of measurements of air volume in samples of different dimensions. In 'Braeburn' there is a gradient of declining air content from just beneath the skin to the centre of the fruit with a sharp discontinuity at the core line. Cell shape and cell packing were observed in the surface layers of freshly excised and stained flesh samples using a dissecting microscope coupled to a video camera and a PC running proprietary software. Tissue organization changed with distance below the skin. It is speculated that reduced internal gas movement, due to the tightly packed tissue of 'Braeburn' and to the potential diffusion barrier at the core line between the cortex and the pith, may increase susceptibility of the flesh to disorders associated with tissue browning and breakdown. PMID:15047764

  14. Air motion sensing hairs of arthropods detect high frequencies at near-maximal mechanical efficiency

    PubMed Central

    Bathellier, Brice; Steinmann, Thomas; Barth, Friedrich G.; Casas, Jérôme

    2012-01-01

    Using measurements based on particle image velocimetry in combination with a novel compact theoretical framework to describe hair mechanics, we found that spider and cricket air motion sensing hairs work close to the physical limit of sensitivity and energy transmission in a broad range of relatively high frequencies. In this range, the hairs closely follow the motion of the incoming flow because a minimum of energy is dissipated by forces acting in their basal articulation. This frequency band is located beyond the frequency at which the angular displacement of the hair is maximum which is between about 40 and 600 Hz, depending on hair length (Barth et al. [1] Phil. Trans. R. Soc. Lond. B 340, 445–461 (doi:10.1098/rstb.1993.0084)). Given that the magnitude of natural airborne signals is known to decrease with frequency, our results point towards the possible existence of spectral signatures in the higher frequency range that may be weak but of biological significance. PMID:22171067

  15. Measurements of ground motion and magnet vibrations at the APS

    SciTech Connect

    Shiltsev, V.

    1996-09-01

    This article presents results of ground motion and magnet vibrations measurements at the Advanced Photon Source. The experiments were done over a wide, frequency range (0-05-100 Hz) with the use of SM-3KV-type seismic probes from the Budker Institute of Nuclear Physics (Russia). Spectral power densities of vertical and horizontal motions of the APS hall floor and quadrupoles on regular supports were obtained. Also investigated were magnet vibrations induced by designed cooling water flow and spectral characteristics of spatial correlation of the quadrupole vibrations at different sectors of the ring. The influence of personnel activity in the hall and traffic under the ring on the slow motion of storage ring elements were observed. Amplitudes of vibrations at the APS are compared with results of seismic measurements at some other accelerators.

  16. Super-Sharp Radio "Vision" Measures Galaxy's Motion in Space

    NASA Astrophysics Data System (ADS)

    2005-03-01

    Astronomers using the National Science Foundation's Very Long Baseline Array (VLBA) have measured the motion across the sky of a galaxy nearly 2.4 million light-years from Earth. While scientists have been measuring the motion of galaxies directly toward or away from Earth for decades, this is the first time that the transverse motion (called proper motion by astronomers) has been measured for a galaxy that is not a satellite of our own Milky Way Galaxy. M33 Radio/Optical Image of M33 CREDIT: NRAO/AUI/NSF, NOAO/AURA/NSF (Click on image for more files) An international scientific team analyzed VLBA observations made over two and a half years to detect minuscule shifts in the sky position of the spiral galaxy M33. Combined with previous measurements of the galaxy's motion toward Earth, the new data allowed the astronomers to calculate M33's movement in three dimensions for the first time. "A snail crawling on Mars would appear to be moving across the surface more than 100 times faster than the motion we measured for this galaxy," said Mark Reid, of the Harvard-Smithsonian Center for Astrophysics in Cambridge, MA. M33 is a satellite of the larger galaxy M31, the well-known Andromeda Galaxy that is the most distant object visible to the naked eye. Both are part of the Local Group of galaxies that includes the Milky Way. In addition to measuring the motion of M33 as a whole, the astronomers also were able to make a direct measurement of the spiral galaxy's rotation. Both measurements were made by observing the changes in position of giant clouds of molecules inside the galaxy. The water vapor in these clouds acts as a natural maser, strengthening, or amplifying, radio emission the same way that lasers amplify light emission. The natural masers acted as bright radio beacons whose movement could be tracked by the ultra-sharp radio "vision" of the VLBA. Reid and his colleagues plan to continue measuring M33's motion and also to make similar measurements of M31's motion

  17. A head motion measurement system suitable for emission computed tomography

    SciTech Connect

    Goldstein, S.R.; Eidsath, A.; Daube-Witherspoon, M.E.; Green, M.V.

    1997-02-01

    Subject motion during brain imaging studies can adversely affect the images through loss of resolution and other artifacts related to movement. The authors have developed and tested a device to measure heat motion externally in real-time during emission computed tomographic (ECT) brain imaging studies, to be used eventually to correct ECT data for that motion. The system is based on optical triangulation of three miniature lights affixed to the patient`s head and viewed by two position-sensitive detectors. The computer-controlled device converts the three sets of lamp positions into rotational and translational coordinates every 0.7 seconds. When compared against a mechanical test fixture, the optical system was found to be linear and accurate with minimal crosstalk between the coordinates. In a study of two subjects, comparing the angular motions measured by the optical device and a commercially available electromagnetic motion detector, the two systems agreed well, with an root mean square (rms) difference of less than 0.6{degree} for all rotations.

  18. Basilar membrane and osseous spiral lamina motion in human cadavers with air and bone conduction stimuli.

    PubMed

    Stenfelt, Stefan; Puria, Sunil; Hato, Naohito; Goode, Richard L

    2003-07-01

    It is generally accepted that bone conduction (BC) stimuli yield a traveling wave on the basilar membrane (BM) and hence stimulate the cochlea by the same mechanisms as normal air conduction (AC). The basis for this is the ability to cancel or mask a BC tone with an AC tone and the ability to generate two tone distortion products with a BC tone and an AC tone. The hypothesis is proposed that BC stimulates the BM not only through the hydrodynamics of the scala vestibuli and scala tympani, but also through osseous spiral lamina (OSL) vibrations. To test this hypothesis the BM and OSL response with AC as well as BC stimulation was measured with a laser Doppler vibrometer. Human temporal bones mounted on a shaker were used to record the velocities of the bone per se, the BM and the OSL. The measurements were then converted to relative BM and OSL velocities. The results from the basal turn of the cochlea show similar behavior with AC and BC stimulation. The motion of the OSL at the edge where it connects to the BM is in phase and is typically 6 dB lower than the BM motion. With BC stimulation, there is less phase accumulation in the OSL after the cochlea is drained; the OSL moves due to inertial forces and resonates at approximately 7 kHz. Inertial vibration of the OSL may partially contribute to the total response of BC sound, especially at the high frequencies, although current models of the cochlea assume a rigid OSL. The measurements reported here can be used to include a flexible OSL in cochlear models.

  19. GPS Measurements Of The Relative Motion Between India And Sundaland

    NASA Astrophysics Data System (ADS)

    Socquet, A.; Vigny, C.; Pubellier, M.; Chamot-Rooke, N.; Rangin, C.

    GPS measurements acquired in the framework of the GEODYSSEA project have pro- vided significant new information on the present day plate tectonics in South East Asia. In order to further investigate the relative motion between India and South East Asia, we have performed a combined processing the THAICA, APRGP, MYANMAR, GEODYSSEA and RTSD data (10 GPS campaigns from 1994 to 2000) including 90 stations in South East Asia. Global plate motion model Nuvel-1A [DeMets et al., 1994] predicts a relative motion of India with respect to Eurasia of about 5.5 cm/yr oriented around N20rE on the east- ern border of the Indian plate in Myanmar. Our geodetic results allow us to confirm That India motion is actually slower than this value in agreement with the results ob- tained by Paul et al., 2001. In addition, since the block along which India is sliding is not stable Eurasia but rather the Sundaland block [Michel et al., 2001], the relative motion expected between India and Sundaland on the Myanmar boundary reduces to about 4.5 cm/yr and rotates towards North. The local Myanmar velocity field [Vigny et al.,2001] show that, out of the 4.5 cm/yr of India versus Sundaland rate, only 3 cm/yr are accommodated in Myanmar, distributed between 2 cm/yr on the Sagaing fault and 1 cm/yr in the Myanmar Central Basins. Therefore, 1.5 cm/yr have to be taken elsewhere. Our results indicate that about 0.5 cm/yr can be accommodated in a large shear zone in Indochina, the remaining motion being accommodated in the Andaman trench. DeMets, C., R. G. Gordon, D. Argus, and S. Stein, Effect of recent revisions to the geomagnetic reversal time scale on estimates of current plate motions, Geophys. Res. Letters., 21, 2191-2194, 1994. Michel, G., Y. Yu, S. Zhu, C. Reigber, M. Becker, E. Reinhart, W. Simons, B. Am- brosius, C. Vigny, N. Chamot-Rooke, X. LePichon, P. Morgan, and S. Matheussen, Crustal motion and block behavior in SE-Asia from GPS measurements,.Earth and Physics Science letters, 187, 289

  20. Measurement of formaldehyde in clean air

    SciTech Connect

    Neitzert, V.; Seiler, W.

    1981-01-01

    A method for the measurement of small amounts of formaldehyde in air has been developed. The method is based on the derivatization of HCHO with 2.4-Denetrophenylhydragine, forming 2.4-Dentrophylhydragine, measured with GC-ECD-technique. HCHO is preconcentrated using a cryogenic sampling technique. The detection limit is 0.05 ppbv for a sampling volume of 200 liter. The method has been applied for measurements in continental and marine air masses showing HCHO mixing ratios of 0.4--5.0 ppbv and 0.2--1.0 ppbv, respectively. HCHO mixing ratios show diurnal variations with maximum values during the early afternoon and minimum values during the early morning. In continental air, HCHO mixing ratios are positively correlated with CO and SO/sub 2/, indicating anthropogenic HCHO sources which are estimated to be 6--11 x 10/sup 12/g/year/sup -1/ on a global scale.

  1. Comparisons between measurement and analysis of fluid motion in internal combustion engines

    SciTech Connect

    Witze, P.O.

    1981-10-01

    The Engine Combustion Technology Project was created for the purpose of promoting the development of advanced piston engine concepts by the development of techniques to measure, analyze, and understand the combustion process. The technologies emphasized in the project include laser-based measurement techniques and large-scale computer simulations. Considerable progress has already been achieved by project participants in modeling engine air motion, fuel sprays, and engine combustion phenomena. This milestone report covers one part of that progress, summarizing the current capabilities of multi-dimensional computer codes being developed by the project to predict the behavior of turbulent air motion in an engine environment. Computed results are compared directly with experimental data in six different areas of importance to internal combustion engines: (1) Induction-generated ring-vortex structures; (2) Piston-induced vortex roll-up; (3) Behavior of turbulence during compression; (4) Decay of swirling flow during compression; (5) Decay of swirling flow in a constant volume engine simulator; (6) Exhaust-pipe flow. The computational procedures used include vortex dynamics, rapid distortion theory, and finite difference models employing two-equation and subgrid-scale turbulence models. Although the capability does not yet exist to predict the air motion in an engine from its geometric configuration alone, the results presented show that many flowfield sub-processes can be predicted given well-specified initial and boundary conditions.

  2. Anisotropic orientational motion of molecular adsorbates at the air-water interface

    SciTech Connect

    Zimdars, D.; Dadap, J.I.; Eisenthal, K.B.; Heinz, T.F.

    1999-04-29

    The ultrafast orientational motions of coumarin 314 (C314) adsorbed at the air/water interface were investigated by time-resolved surface second harmonic generation (TRSHG). The theory and method of using TRSHG to detect both out-of-plane and in-plane orientational motions are discussed. The interfacial solute motions were found to be anisotropic, with differing out-of-plane and in-plane reorientation time constants. This report presents the first direct observation of in-plane orientational motion of a molecule (C314) at the air/water interface using TRSHG. The in-plane reorientation time constant is 600 {+-} 40 ps. The out-of-plane reorientation time constant is 350 {+-} 20 ps. The out-of-plane orientational motion of C314 is similar to the previous results on rhodamine 6G at the air/water interface which indicated increased interfacial friction compared with bulk aqueous solution. The surface reorientation times are 2--3 times slower than the bulk isotropic orientational diffusion time.

  3. Octupole Excitation of Trapped Ion Motion for Precision Mass Measurements

    NASA Astrophysics Data System (ADS)

    Bollen, G.; Ringle, R.; Schury, P.; Schwarz, S.; Sun, T.

    2005-04-01

    National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI, USA An azimuthal octupole radiofrequency field has been used to excite the ion motion of ^40Ar^+ ions stored in a Penning trap. A resonant response was observed at twice the ions' true cyclotron frequency φc=q/m.B. The experiment has been performed with the 9.4-T Penning trap system of the recently commissioned LEBIT facility at the NSCL at MSU [1]. Similar to the excitation with an azimuthal quadrupole field at φc [2,3], octupole excitation at 2φc gives rise to a periodic beating of the ion motion between magnetron and reduced cyclotron motion. Differences are observed in the dependence of the excited ion motion on initial amplitudes and phases of the radial eigen motions. The observed behavior of the ions is found to be in good agreement with the results of numerical simulations. The technique still requires further testing but the first results indicate that 2φc excitation may provide benefits that are similar to doubling the magnetic field strength B. In particular precision mass measurements of short-lived rare isotopes may benefit from this technique by being able to reach a given precision with shorter ion storage and observation times. [1] S. Schwarz et al, Nucl. Instr. Meth. B204 (2004) 507 [2] G. Bollen et al., J. Appl. Phys. 68 (1990) 4355 [3] M. König et al., Int. J. Mass Spec. Ion. Proc. 142 (1995) 95

  4. Probabilistic seismic demand analysis using advanced ground motion intensity measures

    USGS Publications Warehouse

    Tothong, P.; Luco, N.

    2007-01-01

    One of the objectives in performance-based earthquake engineering is to quantify the seismic reliability of a structure at a site. For that purpose, probabilistic seismic demand analysis (PSDA) is used as a tool to estimate the mean annual frequency of exceeding a specified value of a structural demand parameter (e.g. interstorey drift). This paper compares and contrasts the use, in PSDA, of certain advanced scalar versus vector and conventional scalar ground motion intensity measures (IMs). One of the benefits of using a well-chosen IM is that more accurate evaluations of seismic performance are achieved without the need to perform detailed ground motion record selection for the nonlinear dynamic structural analyses involved in PSDA (e.g. record selection with respect to seismic parameters such as earthquake magnitude, source-to-site distance, and ground motion epsilon). For structural demands that are dominated by a first mode of vibration, using inelastic spectral displacement (Sdi) can be advantageous relative to the conventionally used elastic spectral acceleration (Sa) and the vector IM consisting of Sa and epsilon (??). This paper demonstrates that this is true for ordinary and for near-source pulse-like earthquake records. The latter ground motions cannot be adequately characterized by either Sa alone or the vector of Sa and ??. For structural demands with significant higher-mode contributions (under either of the two types of ground motions), even Sdi (alone) is not sufficient, so an advanced scalar IM that additionally incorporates higher modes is used.

  5. Ground motion measurements from the demolition of steel towers

    SciTech Connect

    Joshi, J.R.; Lee, R.C.

    1998-12-31

    Steel towers from a decommissioned heavy water plant were to be demolished. Ground motions due to the proposed felling were estimated in order to assess the structural integrity of neighboring buildings and piping systems. The extraction towers were 125 feet (38.1 m) high in two sizes: 6.5 and 11 feet (1.98 and 3.35 m) inside diameters weighing 215 X 10{sup 3} and 470 X 10{sup 3} lb (956 X 10{sup 3} and 2.1 X 10{sup 6} N). The total potential energy of the tower collapse was about 15 X 10{sup 6} and 32 X 10{sup 6} ft-lb (20.3 X 10{sup 6} and 43.4 X 10{sup 6} Nm) for the small and large towers, respectively. The ground motion predictions were based on a credible theoretical relationship with constants estimated from data available for a different location at the site for dynamic compaction with an energy input an order of magnitude less than that for the towers. Due to the uncertainty of prediction of ground motions a coefficient of variation of 2.0 was used in the structural assessment. Ground motion from the collapse of the extraction towers were monitored by several 3- and 6-components seismographs. Recorded measurements indicated that the ground motion was less than the predicted values. Peak radial motions were approximately equal to the vertical ones. Video tapes of the demolition suggested significant internal energy losses. The measurements suggested that the tower potential energy conversion to dynamic impact energy was about 25 percent. 7 figs.

  6. Measuring the force of drag on air sheared sessile drops

    NASA Astrophysics Data System (ADS)

    Milne, Andrew J. B.; Fleck, Brian; Amirfazli, Alidad

    2012-11-01

    To blow a drop along or off of a surface (i.e. to shed the drop), the drag force on the drop (based on flow conditions, drop shape, and fluid properties) must overcome the adhesion force between the drop and the surface (based on surface tension, drop shape, and contact angle). While the shedding of sessile drops by shear flow has been studied [Milne, A. J. B. & Amirfazli, A. Langmuir 25, 14155 (2009).], no independent measurements of the drag or adhesion forces have been made. Likewise, analytic predictions are limited to hemispherical drops and low air velocities. We present, therefore, measurements of the drag force on sessile drops at air velocities up to the point of incipient motion. Measurements were made using a modified floating element shear sensor in a laminar low speed wind tunnel to record drag force over the surface with the drop absent, and over the combined system of the surface and drop partially immersed in the boundary layer. Surfaces of different wettabilities were used to study the effects of drop shape and contact angles, with drop volume ranged between approximately 10 and 100 microlitres. The drag force for incipient motion (which by definition equals the maximum of the adhesion force) is compared to simplified models for drop adhesion such as that of Furmidge

  7. Advances in Air-Sea Flux Measurement by Eddy Correlation

    NASA Astrophysics Data System (ADS)

    Blomquist, Byron W.; Huebert, Barry J.; Fairall, Christopher W.; Bariteau, Ludovic; Edson, James B.; Hare, Jeffrey E.; McGillis, Wade R.

    2014-09-01

    Eddy-correlation measurements of the oceanic flux are useful for the development and validation of air-sea gas exchange models and for analysis of the marine carbon cycle. Results from more than a decade of published work and from two recent field programs illustrate the principal interferences from water vapour and motion, demonstrating experimental approaches for improving measurement precision and accuracy. Water vapour cross-sensitivity is the greatest source of error for flux measurements using infrared gas analyzers, often leading to a ten-fold bias in the measured flux. Much of this error is not related to optical contamination, as previously supposed. While various correction schemes have been demonstrated, the use of an air dryer and closed-path analyzer is the most effective way to eliminate this interference. This approach also obviates density corrections described by Webb et al. (Q J R Meteorol 106:85-100, 1980). Signal lag and frequency response are a concern with closed-path systems, but periodic gas pulses at the inlet tip provide for precise determination of lag time and frequency attenuation. Flux attenuation corrections are shown to be 5 % for a cavity ring-down analyzer (CRDS) and dryer with a 60-m inlet line. The estimated flux detection limit for the CRDS analyzer and dryer is a factor of ten better than for IRGAs sampling moist air. While ship-motion interference is apparent with all analyzers tested in this study, decorrelation or regression methods are effective in removing most of this bias from IRGA measurements and may also be applicable to the CRDS.

  8. Improving optical bench radius measurements using stage error motion data

    SciTech Connect

    Schmitz, Tony L.; Gardner, Neil; Vaughn, Matthew; Medicus, Kate; Davies, Angela

    2008-12-20

    We describe the application of a vector-based radius approach to optical bench radius measurements in the presence of imperfect stage motions. In this approach, the radius is defined using a vector equation and homogeneous transformation matrix formulism. This is in contrast to the typical technique, where the displacement between the confocal and cat's eye null positions alone is used to determine the test optic radius. An important aspect of the vector-based radius definition is the intrinsic correction for measurement biases, such as straightness errors in the stage motion and cosine misalignment between the stage and displacement gauge axis, which lead to an artificially small radius value if the traditional approach is employed. Measurement techniques and results are provided for the stage error motions, which are then combined with the setup geometry through the analysis to determine the radius of curvature for a spherical artifact. Comparisons are shown between the new vector-based radius calculation, traditional radius computation, and a low uncertainty mechanical measurement. Additionally, the measurement uncertainty for the vector-based approach is determined using Monte Carlo simulation and compared to experimental results.

  9. Arthrometric Measurement of Ankle-Complex Motion: Normative Values

    PubMed Central

    Schwarz, Neil A.; Kovaleski, John E.; Heitman, Robert J.; Gurchiek, Larry R.; Gubler-Hanna, Coral

    2011-01-01

    Abstract Context: Valid and reliable measurements of ankle-complex motion have been reported using the Hollis Ankle Arthrometer. No published normative data of ankle-complex motion obtained from ankle arthrometry are available for use as a reference for clinical decision making. Objective: To describe the distribution variables of ankle-complex motion in uninjured ankles and to establish normative reference values for use in research and to assist in clinical decision making. Design: Descriptive laboratory study. Setting: University research laboratory. Patients or Other Participants: Both ankles of 50 men and 50 women (age = 21.78 ± 2.0 years [range, 19–25 years]) were tested. Intervention(s): Each ankle underwent anteroposterior (AP) and inversion-eversion (I-E) loading using an ankle arthrometer. Main Outcome Measure(s): Recorded anterior, posterior, and total AP displacement (millimeters) at 125 N and inversion, eversion, and total I-E rotation (degrees) at 4 Nm. Results: Women had greater ankle-complex motion for all variables except for posterior displacement. Total AP displacement of the ankle complex was 18.79 ± 4.1 mm for women and 16.70 ± 4.8 mm for men (U = 3742.5, P < .01). Total I-E rotation of the ankle complex was 42.10° ± 9.0° for women and 34.13° ± 10.1° for men (U = 2807, P < .001). All variables were normally distributed except for anterior displacement, inversion rotation, eversion rotation, and total I-E rotation in the women's ankles and eversion rotation in the men's ankles; these variables were skewed positively. Conclusions: Our study increases the available database on ankle-complex motion, and it forms the basis of norm-referenced clinical comparisons and the basis on which quantitative definitions of ankle pathologic conditions can be developed. PMID:21391797

  10. Measuring Air Density in the Introductory Lab

    ERIC Educational Resources Information Center

    Calza, G.; Gratton, L. M.; Lopez-Arias, T.; Oss, S.

    2010-01-01

    The measurement of the mass, or the density, of air can easily be done with very simple materials and offers many interesting phenomena for discussion--buoyancy and its effects being the most obvious but not the only one. Many interesting considerations can be done regarding the behavior of gases, the effect of the external conditions in the…

  11. Dimensional coordinate measurements: application in characterizing cervical spine motion

    NASA Astrophysics Data System (ADS)

    Zheng, Weilong; Li, Linan; Wang, Shibin; Wang, Zhiyong; Shi, Nianke; Xue, Yuan

    2014-06-01

    Cervical spine as a complicated part in the human body, the form of its movement is diverse. The movements of the segments of vertebrae are three-dimensional, and it is reflected in the changes of the angle between two joint and the displacement in different directions. Under normal conditions, cervical can flex, extend, lateral flex and rotate. For there is no relative motion between measuring marks fixed on one segment of cervical vertebra, the cervical vertebrae with three marked points can be seen as a body. Body's motion in space can be decomposed into translational movement and rotational movement around a base point .This study concerns the calculation of dimensional coordinate of the marked points pasted to the human body's cervical spine by an optical method. Afterward, these measures will allow the calculation of motion parameters for every spine segment. For this study, we choose a three-dimensional measurement method based on binocular stereo vision. The object with marked points is placed in front of the CCD camera. Through each shot, we will get there two parallax images taken from different cameras. According to the principle of binocular vision we can be realized three-dimensional measurements. Cameras are erected parallelly. This paper describes the layout of experimental system and a mathematical model to get the coordinates.

  12. Measure Guideline: Guide to Attic Air Sealing

    SciTech Connect

    Lstiburek, J.

    2014-09-01

    The Guide to Attic Air Sealing was completed in 2010 and although not in the standard Measure Guideline format, is intended to be a Measure Guideline on Attic Air Sealing. The guide was reviewed during two industry stakeholders meetings held on December 18th, 2009 and January 15th, 2010, and modified based on the comments received. Please do not make comments on the Building America format of this document. The purpose of the Guide to Attic Air Sealing is to provide information and recommendations for the preparation work necessary prior to adding attic insulation. Even though the purpose of this guide is to save energy - health, safety and durability should not be compromised by energy efficiency. Accordingly, combustion safety and ventilation for indoor air quality are addressed first. Durability and attic ventilation then follow. Finally, to maximize energy savings, air sealing is completed prior to insulating. The guide is intended for home remodelers, builders, insulation contractors, mechanical contractors, general contractors who have previously done remodeling and homeowners as a guide to the work that needs to be done.

  13. Solving the aerodynamics of fungal flight: how air viscosity slows spore motion.

    PubMed

    Fischer, Mark W F; Stolze-Rybczynski, Jessica L; Davis, Diana J; Cui, Yunluan; Money, Nicholas P

    2010-01-01

    Viscous drag causes the rapid deceleration of fungal spores after high-speed launches and limits discharge distance. Stokes' law posits a linear relationship between drag force and velocity. It provides an excellent fit to experimental measurements of the terminal velocity of free-falling spores and other instances of low Reynolds number motion (Re<1). More complex, non-linear drag models have been devised for movements characterized by higher Re, but their effectiveness for modeling the launch of fast-moving fungal spores has not been tested. In this paper, we use data on spore discharge processes obtained from ultra-high-speed video recordings to evaluate the effects of air viscosity predicted by Stokes' law and a commonly used non-linear drag model. We find that discharge distances predicted from launch speeds by Stokes' model provide a much better match to measured distances than estimates from the more complex drag model. Stokes' model works better over a wide range projectile sizes, launch speeds, and discharge distances, from microscopic mushroom ballistospores discharged at <1 m s(-1) over a distance of <0.1mm (Re<1.0), to macroscopic sporangia of Pilobolus that are launched at >10 m s(-1) and travel as far as 2.5m (Re>100). PMID:21036338

  14. Solving the aerodynamics of fungal flight: how air viscosity slows spore motion.

    PubMed

    Fischer, Mark W F; Stolze-Rybczynski, Jessica L; Davis, Diana J; Cui, Yunluan; Money, Nicholas P

    2010-01-01

    Viscous drag causes the rapid deceleration of fungal spores after high-speed launches and limits discharge distance. Stokes' law posits a linear relationship between drag force and velocity. It provides an excellent fit to experimental measurements of the terminal velocity of free-falling spores and other instances of low Reynolds number motion (Re<1). More complex, non-linear drag models have been devised for movements characterized by higher Re, but their effectiveness for modeling the launch of fast-moving fungal spores has not been tested. In this paper, we use data on spore discharge processes obtained from ultra-high-speed video recordings to evaluate the effects of air viscosity predicted by Stokes' law and a commonly used non-linear drag model. We find that discharge distances predicted from launch speeds by Stokes' model provide a much better match to measured distances than estimates from the more complex drag model. Stokes' model works better over a wide range projectile sizes, launch speeds, and discharge distances, from microscopic mushroom ballistospores discharged at <1 m s(-1) over a distance of <0.1mm (Re<1.0), to macroscopic sporangia of Pilobolus that are launched at >10 m s(-1) and travel as far as 2.5m (Re>100).

  15. Review of air flow measurement techniques

    SciTech Connect

    McWilliams, Jennifer

    2002-12-01

    Airflow measurement techniques are necessary to determine the most basic of indoor air quality questions: ''Is there enough fresh air to provide a healthy environment for the occupants of the building?'' This paper outlines airflow measurement techniques, but it does not make recommendations for techniques that should be used. The airflows that will be discussed are those within a room or zone, those between rooms or zones, such as through doorways (open or closed) or passive vents, those between the building and outdoors, and those through mechanical air distribution systems. Techniques that are highlighted include particle streak velocimetry, hot wire anemometry, fan pressurization (measuring flow at a given pressure), tracer gas, acoustic methods for leak size determination, the Delta Q test to determine duct leakage flows, and flow hood measurements. Because tracer gas techniques are widely used to measure airflow, this topic is broken down into sections as follows: decay, pulse injection, constant injection, constant concentration, passive sampling, and single and multiple gas measurements for multiple zones.

  16. Measured quantum probability distribution functions for Brownian motion

    SciTech Connect

    Ford, G. W.; O'Connell, R. F.

    2007-10-15

    The quantum analog of the joint probability distributions describing a classical stochastic process is introduced. A prescription is given for constructing the quantum distribution associated with a sequence of measurements. For the case of quantum Brownian motion this prescription is illustrated with a number of explicit examples. In particular, it is shown how the prescription can be extended in the form of a general formula for the Wigner function of a Brownian particle entangled with a heat bath.

  17. Measure Guideline: Guide to Attic Air Sealing

    SciTech Connect

    Lstiburek, Joseph

    2014-09-01

    The purpose of this measure guideline is to provide information and recommendations for the preparation work necessary prior to adding attic insulation. Even though the purpose of this guide is to save energy, health, safety, and durability should not be compromised by energy efficiency. Accordingly, combustion safety and ventilation for indoor air quality are addressed first. Durability and attic ventilation then follow. Finally, to maximize energy savings, air sealing is completed prior to insulating. The guide is intended for home remodelers, builders, insulation contractors, mechanical contractors, general contractors who have previously done remodeling and homeowners as a guide to the work that needs to be done.

  18. 40 CFR 91.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... with intake air other than the ambient air in the test cell (i.e., air which has been pumbed directly to the engine air intake system). For engines which use ambient test cell air for the engine intake... the humidity conditioning has taken place. (b) Unconditioned air supply. Humidity measurements...

  19. 40 CFR 90.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... engines which are supplied with intake air other than the ambient air in the test cell (i.e., air which has been pumped directly to the engine air intake system). For engines which use ambient test cell air for the engine intake air, the ambient test cell humidity measurement may be used. (a)...

  20. 40 CFR 91.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... with intake air other than the ambient air in the test cell (i.e., air which has been pumbed directly to the engine air intake system). For engines which use ambient test cell air for the engine intake... the humidity conditioning has taken place. (b) Unconditioned air supply. Humidity measurements...

  1. 40 CFR 90.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... engines which are supplied with intake air other than the ambient air in the test cell (i.e., air which has been pumped directly to the engine air intake system). For engines which use ambient test cell air for the engine intake air, the ambient test cell humidity measurement may be used. (a)...

  2. 40 CFR 91.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Intake air flow measurement... Procedures § 91.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure the air flow over the...

  3. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Air flow measurement specifications... Emission Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement method used must have a range large enough to accurately measure the air flow over the engine operating...

  4. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Air flow measurement specifications. 89... Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement method used must have a range large enough to accurately measure the air flow over the engine operating...

  5. 40 CFR 91.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Intake air flow measurement... Procedures § 91.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure the air flow over the...

  6. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Air flow measurement specifications... Emission Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement method used must have a range large enough to accurately measure the air flow over the engine operating...

  7. 40 CFR 91.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Intake air flow measurement... Procedures § 91.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure the air flow over the...

  8. 40 CFR 91.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Intake air flow measurement... Procedures § 91.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure the air flow over the...

  9. Velocity measurements by laser resonance fluorescence. [single atom diffusional motion

    NASA Technical Reports Server (NTRS)

    She, C. Y.; Fairbank, W. M., Jr.

    1980-01-01

    The photonburst correlation method was used to detect single atoms in a buffer gas. Real time flow velocity measurements with laser induced resonance fluorescence from single or multiple atoms was demonstrated and this method was investigated as a tool for wind tunnel flow measurement. Investigations show that single atoms and their real time diffusional motion on a buffer gas can be measured by resonance fluorescence. By averaging over many atoms, flow velocities up to 88 m/s were measured in a time of 0.5 sec. It is expected that higher flow speeds can be measured and that the measurement time can be reduced by a factor of 10 or more by careful experimental design. The method is clearly not ready for incorporation in high speed wind tunnels because it is not yet known whether the stray light level will be higher or lower, and it is not known what detection efficiency can be obtained in a wind tunnel situation.

  10. A disk-type capacitive sensor for five-dimensional motion measurements

    NASA Astrophysics Data System (ADS)

    Ahn, Hyeong-Joon; Park, Jung-Ho; Um, Chang-Yong; Han, Dong-Chul

    2008-04-01

    This paper presents a disk-type capacitive sensor for the simultaneous measurement of five-dimensional motions of a target. The sensor detects both air gap and mutual area changes for these five-dimensional motions. In addition, the sensor is manufactured with a printed circuit board (PCB), which reduces manufacturing costs. The sensor is optimally designed through both an error analysis of possible mechanical errors and a finite element analysis of the parasitic capacitances. Furthermore, the sensor can correct measurement errors due to the initial misalignment between the sensor and the target. A prototype PCB sensor, electronics and a test rig were built, and the effectiveness of the developed sensor was proved through experiments.

  11. Simultaneous sizing and electrophoretic mobility measurement of sub-micron particles using Brownian motion.

    PubMed

    Palanisami, Akilan; Miller, John H

    2010-10-01

    The size and surface chemistry of micron scale particles are of fundamental importance in studies of biology and air particulate pollution. However, typical electrophoretic measurements of these and other sub-micron scale particles (300 nm-1 μm) cannot resolve size information within heterogeneous mixtures unambiguously. Using optical microscopy, we monitor electrophoretic motion together with the Brownian velocity fluctuations - using the latter to measure size by either the Green-Kubo relation or by calibration from known size standards. Particle diameters are resolved to ±12% with 95% confidence. Strikingly, the size resolution improves as the particle size decreases due to the increased Brownian motion. The sizing ability of the Brownian assessed electrophoresis method described here complements the electrophoretic mobility resolution of the traditional CE. PMID:20882556

  12. DCShake: Measuring Variations in Earthquake Ground Motions in Washington, DC

    NASA Astrophysics Data System (ADS)

    Pratt, T. L.; Horton, J. W., Jr.; Hough, S. E.; Munoz, J.; Chapman, M. C.; Olgun, G.; Beale, J.

    2015-12-01

    During the 2011 Mw5.8 Mineral, VA earthquake, many buildings in Washington DC, including national landmarks like the Washington National Cathedral, the Smithsonian "Castle," and the Washington Monument, sustained damage despite being 130 km from the epicenter. The surprisingly large amount of damage from weak bedrock ground motions raises questions of whether and how the local geologic materials beneath the city amplify ground motions. In particular, how much and at what frequencies do the southeast-thickening sedimentary strata of the Atlantic Coastal Plain (ACP) strata, sitting on crystalline bedrock, amplify and possibly trap energy? Between November 2014 and August 2015, we used 27 seismometers to measure ground motions across the city during teleseismic and regional earthquakes. Four sites on Piedmont crystalline rocks in NW Washington served as bedrock reference sites, and 23 sites were on ACP strata between 11 m and 200 m thick. Recordings of teleseisms and regional earthquakes provide data with sufficiently high signal-to-noise for computing spectral ratios of the horizontal ground shaking relative to the average of the 4 bedrock sites. Preliminary results are consistent with the primary influence on the amplitudes of ground motions coming from the ACP strata. At frequencies below 1 Hz most sites showed little difference in amplification relative to bedrock, suggesting that basement rocks beneath the ACP strata exert little influence on ground shaking. Strong spectral amplifications of a factor or 10 or greater at frequencies of 1 Hz and above are interpreted as being caused by the ACP strata, with the largest amplitudes at frequencies near the fundamental resonance frequency. A gradual decrease in amplification with higher frequencies above the fundamental peak is consistent with harmonics and resonances from within ACP strata. Results indicate significant amplification of ground motions in the DC area, the frequencies of which will be compared to the

  13. Amine Measurements in Boreal Forest Air

    NASA Astrophysics Data System (ADS)

    Hemmilä, Marja; Hellén, Heidi; Makkonen, Ulla; Hakola, Hannele

    2015-04-01

    Amines are reactive, volatile bases in the air with a general formula of RNH2, R2NH or R3N. Especially small amines can stabilize sulphuric acid clusters and hence affect nucleation. Amines react rapidly with hydroxyl radical (OH˙) thus affecting oxidative capacity of the atmosphere. The amine concentrations are higher in forest air than in urban air (Hellén et al., 2014), but the sources are not known. In order to get more information concerning amine sources, we conducted a measurement campaign in a boreal forest. At SMEAR II station at Hyytiälä, Southern Finland (61°510'N, 24°170'E, 180 m a.s.l.) The measurements cover seven months, from June to December 2014. For sampling and measuring we used MARGA (The instrument for Measuring AeRosols and Gases in Ambient air) which is an on-line ion chromatograph (IC) connected to a sampling system. The IC component of the MARGA system was coupled to an electrospray ionization quadrupole mass spectrometer (MS) to improve sensitivity of amine measurements. This new set-up enabled amine concentration measurements in ambient air both in aerosol and gas phases with a time resolution of only 1 hour. With MARGA-MS we analysed 7 different amines: monomethylamine (MMA), dimethylamine (DMA), trimethylamine (TMA), ethylamine (EA), diethylamine (DEA), propylamine (PA) and butylamine (BA). In preliminary data-analysis we found out, that in June and July most of the measured amines were in gas phase, and particle phase amine concentrations were mostly under detection limits (<1.7 pptv). In June the gaseous amine concentrations were higher than in July. The measured concentrations of gaseous amines followed temperature variation, which could indicate that amines are produced and emitted from the environment or re-emitted from the surfaces as temperature rises after deposition during night-time. All measured amines had similar diurnal variation with maxima during afternoon and minima during night. Results from other months will also

  14. Imaging motional Stark effect measurements at ASDEX Upgrade

    NASA Astrophysics Data System (ADS)

    Ford, O. P.; Burckhart, A.; McDermott, R.; Pütterich, T.; Wolf, R. C.

    2016-11-01

    This paper presents an overview of results from the Imaging Motional Stark Effect (IMSE) diagnostic obtained during its first measurement campaign at ASDEX Upgrade since installation as a permanent diagnostic. A brief overview of the IMSE technique is given, followed by measurements of a standard H-mode discharge, which are compared to equilibrium reconstructions showing good agreement where expected. The development of special discharges for the calibration of pitch angle is reported and safety factor profile changes during sawteeth crashes are shown, which can be resolved to a few percent due to the high sensitivity at good time resolution of the new IMSE system.

  15. On modeling animal movements using Brownian motion with measurement error.

    PubMed

    Pozdnyakov, Vladimir; Meyer, Thomas; Wang, Yu-Bo; Yan, Jun

    2014-02-01

    Modeling animal movements with Brownian motion (or more generally by a Gaussian process) has a long tradition in ecological studies. The recent Brownian bridge movement model (BBMM), which incorporates measurement errors, has been quickly adopted by ecologists because of its simplicity and tractability. We discuss some nontrivial properties of the discrete-time stochastic process that results from observing a Brownian motion with added normal noise at discrete times. In particular, we demonstrate that the observed sequence of random variables is not Markov. Consequently the expected occupation time between two successively observed locations does not depend on just those two observations; the whole path must be taken into account. Nonetheless, the exact likelihood function of the observed time series remains tractable; it requires only sparse matrix computations. The likelihood-based estimation procedure is described in detail and compared to the BBMM estimation.

  16. Exposure measurement for air-pollution epidemiology

    SciTech Connect

    Ferris, B.G.; Ware, J.H.; Spengler, J.D.

    1988-08-01

    The chapter describes the evolution of air-pollution epidemiology over a period when changes in pollution technologies have both lowered total exposures and dispersed them over vastly greater areas. Since personal exposure and microenvironmental measurements are expensive, studies oriented toward measurements of total exposure will be smaller and more intensive. The shift in emphasis to total human exposure also will affect health risk assessment and raise difficult issues in the regulatory domain. Considering that outdoor exposures (for which EPA has a regulatory mandate) occur in the context of exposures from other sources, the potential effect of regulatory action would probably be small. The regulatory issues are even more difficult for particulate air pollution since cigarette smoking is the strongest determinant of indoor levels but the EPA lacks regulatory responsibility for cigarette smoke.

  17. 40 CFR 91.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air temperature... Provisions § 91.309 Engine intake air temperature measurement. (a) Engine intake air temperature measurement... the supply system or in the air stream entering the engine. (b) The temperature measurements must...

  18. 40 CFR 91.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine intake air temperature... Provisions § 91.309 Engine intake air temperature measurement. (a) Engine intake air temperature measurement... the supply system or in the air stream entering the engine. (b) The temperature measurements must...

  19. 40 CFR 91.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine intake air temperature... Provisions § 91.309 Engine intake air temperature measurement. (a) Engine intake air temperature measurement... the supply system or in the air stream entering the engine. (b) The temperature measurements must...

  20. 40 CFR 91.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine intake air temperature... Provisions § 91.309 Engine intake air temperature measurement. (a) Engine intake air temperature measurement... the supply system or in the air stream entering the engine. (b) The temperature measurements must...

  1. 40 CFR 91.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine intake air temperature... Provisions § 91.309 Engine intake air temperature measurement. (a) Engine intake air temperature measurement... the supply system or in the air stream entering the engine. (b) The temperature measurements must...

  2. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Air flow measurement specifications. 89.414 Section 89.414 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Emission Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement...

  3. 40 CFR 91.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine intake air humidity measurement... Provisions § 91.310 Engine intake air humidity measurement. This section refers to engines which are supplied... air, the ambient testcell humidity measurement may be used. (a) Humidity conditioned air supply....

  4. 40 CFR 91.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine intake air humidity measurement... Provisions § 91.310 Engine intake air humidity measurement. This section refers to engines which are supplied... air, the ambient testcell humidity measurement may be used. (a) Humidity conditioned air supply....

  5. 40 CFR 91.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine intake air humidity measurement... Provisions § 91.310 Engine intake air humidity measurement. This section refers to engines which are supplied... air, the ambient testcell humidity measurement may be used. (a) Humidity conditioned air supply....

  6. Methodological aspects of EEG and body dynamics measurements during motion

    PubMed Central

    Reis, Pedro M. R.; Hebenstreit, Felix; Gabsteiger, Florian; von Tscharner, Vinzenz; Lochmann, Matthias

    2014-01-01

    EEG involves the recording, analysis, and interpretation of voltages recorded on the human scalp which originate from brain gray matter. EEG is one of the most popular methods of studying and understanding the processes that underlie behavior. This is so, because EEG is relatively cheap, easy to wear, light weight and has high temporal resolution. In terms of behavior, this encompasses actions, such as movements that are performed in response to the environment. However, there are methodological difficulties which can occur when recording EEG during movement such as movement artifacts. Thus, most studies about the human brain have examined activations during static conditions. This article attempts to compile and describe relevant methodological solutions that emerged in order to measure body and brain dynamics during motion. These descriptions cover suggestions on how to avoid and reduce motion artifacts, hardware, software and techniques for synchronously recording EEG, EMG, kinematics, kinetics, and eye movements during motion. Additionally, we present various recording systems, EEG electrodes, caps and methods for determinating real/custom electrode positions. In the end we will conclude that it is possible to record and analyze synchronized brain and body dynamics related to movement or exercise tasks. PMID:24715858

  7. Sea ice motion measurements from Seasat SAR images

    NASA Technical Reports Server (NTRS)

    Leberl, F.; Raggam, J.; Elachi, C.; Campbell, W. J.

    1983-01-01

    Data from the Seasat synthetic aperture radar (SAR) experiment are analyzed in order to determine the accuracy of this information for mapping the distribution of sea ice and its motion. Data from observations of sea ice in the Beaufort Sea from seven sequential orbits of the satellite were selected to study the capabilities and limitations of spaceborne radar application to sea-ice mapping. Results show that there is no difficulty in identifying homologue ice features on sequential radar images and the accuracy is entirely controlled by the accuracy of the orbit data and the geometric calibration of the sensor. Conventional radargrammetric methods are found to serve well for satellite radar ice mapping, while ground control points can be used to calibrate the ice location and motion measurements in the cases where orbit data and sensor calibration are lacking. The ice motion was determined to be approximately 6.4 + or - 0.5 km/day. In addition, the accuracy of pixel location was found over land areas. The use of one control point in 10,000 sq km produced an accuracy of about + or 150 m, while with a higher density of control points (7 in 1000 sq km) the location accuracy improves to the image resolution of + or - 25 m. This is found to be applicable for both optical and digital data.

  8. Measurement of air entrainment in plasma jets

    NASA Astrophysics Data System (ADS)

    Fincke, J. R.; Rodriquez, R.; Pentecost, C. G.

    The concentration and temperature of air entrained into argon and helium plasma jets has been measured using coherent anti-Stokes Raman spectroscopy (CARS). The argon plasma flow field is characterized by a short region of well behaved laminar flow near the nozzle exit followed by an abrupt transition to turbulence. Once the transition of turbulence occurs, air is rapidly mixed into the jet core. The location of the transition region is determined by the rapid cooling of the jet and the resulting increase in Reynolds number. In contrast, the helium plasma flow field never exceeds a Reynolds number of 200 and remains laminar. The entrainment process in this case is controlled by molecular diffusion rather than turbulent mixing.

  9. Measurement of air entrainment in plasma jets

    SciTech Connect

    Fincke, J.R.; Rodriquez, R.; Pentecost, C.G.

    1990-01-01

    The concentration and temperature of air entrained into argon and helium plasma jets has been measured using coherent anti-Stokes Raman spectroscopy (CARS). The argon plasma flow field is characterized by a short region of well behaved laminar flow near the nozzle exit followed by an abrupt transition to turbulence. Once the transition of turbulence occurs, air is rapidly mixed into the jet core. The location of the transition region is determined by the rapid cooling of the jet and the resulting increase in Reynolds number. In contrast, the helium plasma flow field never exceeds a Reynolds number of 200 and remains laminar. The entrainment process in this case is controlled by molecular diffusion rather than turbulent mixing. 9 refs., 5 figs., 1 tab.

  10. 40 CFR 92.108 - Intake and cooling air measurements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... recommended practice J244 (incorporated by reference at § 92.5) are allowed. (b) Humidity and temperature measurements. (1) Air that has had its absolute humidity altered is considered humidity-conditioned air. For this type of intake air supply, the humidity measurements must be made within the intake air...

  11. 40 CFR 92.108 - Intake and cooling air measurements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... practice J244 (incorporated by reference at § 92.5) are allowed. (b) Humidity and temperature measurements. (1) Air that has had its absolute humidity altered is considered humidity-conditioned air. For this type of intake air supply, the humidity measurements must be made within the intake air supply...

  12. 40 CFR 92.108 - Intake and cooling air measurements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... recommended practice J244 (incorporated by reference at § 92.5) are allowed. (b) Humidity and temperature measurements. (1) Air that has had its absolute humidity altered is considered humidity-conditioned air. For this type of intake air supply, the humidity measurements must be made within the intake air...

  13. 40 CFR 92.108 - Intake and cooling air measurements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... recommended practice J244 (incorporated by reference at § 92.5) are allowed. (b) Humidity and temperature measurements. (1) Air that has had its absolute humidity altered is considered humidity-conditioned air. For this type of intake air supply, the humidity measurements must be made within the intake air...

  14. Correlated Protein Motion Measurements of Dihydrofolate Reductase Crystals

    NASA Astrophysics Data System (ADS)

    Xu, Mengyang; Niessen, Katherine; Pace, James; Cody, Vivian; Markelz, Andrea

    2014-03-01

    We report the first direct measurements of the long range structural vibrational modes in dihydrofolate reductase (DHFR). DHFR is a universal housekeeping enzyme that catalyzes the reduction of 7,8-dihydrofolate to 5,6,7,8-tetra-hydrofolate, with the aid of coenzyme nicotinamide adenine dinucleotide phosphate (NADPH). This crucial enzymatic role as the target for anti-cancer [methotrexate (MTX)], and other clinically useful drugs, has made DHFR a long-standing target of enzymological studies. The terahertz (THz) frequency range (5-100 cm-1), corresponds to global correlated protein motions. In our lab we have developed Crystal Anisotropy Terahertz Microscopy (CATM), which directly measures these large scale intra-molecular protein vibrations, by removing the relaxational background of the solvent and residue side chain librational motions. We demonstrate narrowband features in the anisotropic absorbance for mouse DHFR with the ligand binding of NADPH and MTX single crystals as well as Escherichia coli DHFR with the ligand binding of NADPH and MTX single crystals. This work is supported by NSF grant MRI2 grant DBI2959989.

  15. 40 CFR 90.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Intake air flow measurement... Gaseous Exhaust Test Procedures § 90.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure...

  16. 40 CFR 90.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Intake air flow measurement... Gaseous Exhaust Test Procedures § 90.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure...

  17. 40 CFR 90.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Intake air flow measurement... Gaseous Exhaust Test Procedures § 90.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure...

  18. 40 CFR 90.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Intake air flow measurement... Gaseous Exhaust Test Procedures § 90.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure...

  19. Air pollution measurements in traffic tunnels.

    PubMed

    De Fré, R; Bruynseraede, P; Kretzschmar, J G

    1994-10-01

    Air pollution measurements during April 1991 are reported from the Craeybeckx highway tunnel in Antwerp, Belgium. The tunnel was used daily by an average of 45,000 vehicles, of which 60% were gasoline fueled passenger cars, 20% diesel cars, and 20% trucks. Of the gasoline cars, only 3% had three-way catalysts. Tunnel air concentrations of nitrogen oxides, sulphur dioxide, carbon dioxide, carbon monoxide, nonmethane hydrocarbons, volatile organic compounds, polycyclic aromatic hydrocarbons, and lead are presented. The traffic emissions in the tunnel are calculated by the carbon balance method, which uses the increase of the total carbon concentration in the tunnel air as the reference quantity. Division of the concentration of any pollutant by the total carbon concentration gives emission factors per kilogram of carbon. These emission factors can be converted directly to emissions relative to fuel consumption or per kilometer. The fraction of diesel used in the tunnel was derived from sulphur to carbon ratios in tunnel air. A calculation procedure with breakdown of emission factors according to vehicle categories was used to estimate countrywide emissions. The estimated emissions were compared to results from the Flanders Emissions Inventory [Emissie Inventaris Vlaamse Regio (EIVR)] and calculated emissions according to the emission factors proposed by the European Commissions CORINAIR Working Group. For NOx there is excellent agreement. For carbon monoxide and hydrocarbons, the tunnel data produced higher emissions than the CORINAIR model would predict but lower than the official EIVR statistics. The estimated lead emissions from traffic are found to be 22 to 29% of the lead in gasoline.

  20. Comparison of Functional Ankle Motion Measures in Modern Dancers.

    PubMed

    Dickson, Danelle; Hollman-Gage, Kendra; Ojofeitimi, Sheyi; Bronner, Shaw

    2012-09-01

    Ankle injuries are the most common lower extremity injury in dance and sports, often resulting in limitation of dorsiflexion or plantar flexion. Accurate assessment of any limitation in range of motion is an important factor in implementing effective preventative and rehabilitative regimens. Ankle range of motion has traditionally been quantified with goniometers. However, standard goniometry may not be an adequate method of assessing plantar flexion range of motion in dancers. An alternative technique using inclinometers to quantify ankle plantar flexion has been reported, but reliability and inter-instrument correlations for this method are limited. The dorsiflexion lunge distance method has been used to assess ankle dorsiflexion. Although shown to be reliable, this method has not been objectively correlated. The purpose of this study was to determine the most clinically appropriate tool for assessing functional ankle dorsiflexion and plantar flexion in dancers. The aims were to: 1. determine reliability of the weightbearing ankle dorsiflexion lunge method using inclinometer, goniometer, and distance; 2. assess the reliability of inclinometer and goniometer measurements of non-weightbearing active plantar flexion; 3. conduct inter-method and experienced versus novice rater correlations; and 4. determine if a relationship exists between dorsiflexion distance (cm) and dorsiflexion inclinometer angle (degrees) measurements. Twenty-six modern dancers (age: 20.2 ± 1.8 years) participated in the study. Four raters measured weightbearing dorsiflexion in a lunge position using a goniometer, two inclinometer placements, and a distance measurement. They also measured active ankle plantar flexion using an inclinometer placed on the anterior talonavicular joint and a goniometer placed at the lateral ankle. Intra- and inter-rater reliability and inter-method correlations were calculated with Intraclass Correlation Coefficients (ICC) and standard error of measurement (SEM

  1. Laser filamentation induced air-flow motion in a diffusion cloud chamber.

    PubMed

    Sun, Haiyi; Liu, Jiansheng; Wang, Cheng; Ju, Jingjing; Wang, Zhanxin; Wang, Wentao; Ge, Xiaochun; Li, Chuang; Chin, See Leang; Li, Ruxin; Xu, Zhizhan

    2013-04-22

    We numerically simulated the air-flow motion in a diffusion cloud chamber induced by femtosecond laser filaments for different chopping rates. A two dimensional model was employed, where the laser filaments were treated as a heat flux source. The simulated patterns of flow fields and maximum velocity of updraft compare well with the experimental results for the chopping rates of 1, 5, 15 and 150 Hz. A quantitative inconsistency appears between simulated and experimental maximum velocity of updraft for 1 kHz repetition rate although a similar pattern of flow field is obtained, and the possible reasons were analyzed. Based on the present simulated results, the experimental observation of more water condensation/snow at higher chopping rate can be explained. These results indicate that the specific way of laser filament heating plays a significant role in the laser-induced motion of air flow, and at the same time, our previous conclusion of air flow having an important effect on water condensation/snow is confirmed.

  2. Laser filamentation induced air-flow motion in a diffusion cloud chamber.

    PubMed

    Sun, Haiyi; Liu, Jiansheng; Wang, Cheng; Ju, Jingjing; Wang, Zhanxin; Wang, Wentao; Ge, Xiaochun; Li, Chuang; Chin, See Leang; Li, Ruxin; Xu, Zhizhan

    2013-04-22

    We numerically simulated the air-flow motion in a diffusion cloud chamber induced by femtosecond laser filaments for different chopping rates. A two dimensional model was employed, where the laser filaments were treated as a heat flux source. The simulated patterns of flow fields and maximum velocity of updraft compare well with the experimental results for the chopping rates of 1, 5, 15 and 150 Hz. A quantitative inconsistency appears between simulated and experimental maximum velocity of updraft for 1 kHz repetition rate although a similar pattern of flow field is obtained, and the possible reasons were analyzed. Based on the present simulated results, the experimental observation of more water condensation/snow at higher chopping rate can be explained. These results indicate that the specific way of laser filament heating plays a significant role in the laser-induced motion of air flow, and at the same time, our previous conclusion of air flow having an important effect on water condensation/snow is confirmed. PMID:23609636

  3. Lumbar joint torque estimation based on simplified motion measurement using multiple inertial sensors.

    PubMed

    Miyajima, Saori; Tanaka, Takayuki; Imamura, Yumeko; Kusaka, Takashi

    2015-01-01

    We estimate lumbar torque based on motion measurement using only three inertial sensors. First, human motion is measured by a 6-axis motion tracking device that combines a 3-axis accelerometer and a 3-axis gyroscope placed on the shank, thigh, and back. Next, the lumbar joint torque during the motion is estimated by kinematic musculoskeletal simulation. The conventional method for estimating joint torque uses full body motion data measured by an optical motion capture system. However, in this research, joint torque is estimated by using only three link angles of the body, thigh, and shank. The utility of our method was verified by experiments. We measured motion of bendung knee and waist simultaneously. As the result, we were able to estimate the lumbar joint torque from measured motion. PMID:26737834

  4. Lumbar joint torque estimation based on simplified motion measurement using multiple inertial sensors.

    PubMed

    Miyajima, Saori; Tanaka, Takayuki; Imamura, Yumeko; Kusaka, Takashi

    2015-01-01

    We estimate lumbar torque based on motion measurement using only three inertial sensors. First, human motion is measured by a 6-axis motion tracking device that combines a 3-axis accelerometer and a 3-axis gyroscope placed on the shank, thigh, and back. Next, the lumbar joint torque during the motion is estimated by kinematic musculoskeletal simulation. The conventional method for estimating joint torque uses full body motion data measured by an optical motion capture system. However, in this research, joint torque is estimated by using only three link angles of the body, thigh, and shank. The utility of our method was verified by experiments. We measured motion of bendung knee and waist simultaneously. As the result, we were able to estimate the lumbar joint torque from measured motion.

  5. Patient motion tracking in the presence of measurement errors.

    PubMed

    Haidegger, Tamás; Benyó, Zoltán; Kazanzides, Peter

    2009-01-01

    The primary aim of computer-integrated surgical systems is to provide physicians with superior surgical tools for better patient outcome. Robotic technology is capable of both minimally invasive surgery and microsurgery, offering remarkable advantages for the surgeon and the patient. Current systems allow for sub-millimeter intraoperative spatial positioning, however certain limitations still remain. Measurement noise and unintended changes in the operating room environment can result in major errors. Positioning errors are a significant danger to patients in procedures involving robots and other automated devices. We have developed a new robotic system at the Johns Hopkins University to support cranial drilling in neurosurgery procedures. The robot provides advanced visualization and safety features. The generic algorithm described in this paper allows for automated compensation of patient motion through optical tracking and Kalman filtering. When applied to the neurosurgery setup, preliminary results show that it is possible to identify patient motion within 700 ms, and apply the appropriate compensation with an average of 1.24 mm positioning error after 2 s of setup time.

  6. 40 CFR 89.325 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air temperature... Test Equipment Provisions § 89.325 Engine intake air temperature measurement. (a) Engine intake air temperature measurement must be made within 122 cm of the engine. The measurement location must be made...

  7. 40 CFR 89.325 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine intake air temperature... Test Equipment Provisions § 89.325 Engine intake air temperature measurement. (a) Engine intake air temperature measurement must be made within 122 cm of the engine. The measurement location must be made...

  8. 40 CFR 89.325 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine intake air temperature... Test Equipment Provisions § 89.325 Engine intake air temperature measurement. (a) Engine intake air temperature measurement must be made within 122 cm of the engine. The measurement location must be made...

  9. 40 CFR 89.325 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine intake air temperature... Test Equipment Provisions § 89.325 Engine intake air temperature measurement. (a) Engine intake air temperature measurement must be made within 122 cm of the engine. The measurement location must be made...

  10. 40 CFR 89.325 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine intake air temperature... Test Equipment Provisions § 89.325 Engine intake air temperature measurement. (a) Engine intake air temperature measurement must be made within 122 cm of the engine. The measurement location must be made...

  11. 40 CFR 90.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine intake air humidity measurement... Emission Test Equipment Provisions § 90.310 Engine intake air humidity measurement. This section refers to... for the engine intake air, the ambient test cell humidity measurement may be used. (a)...

  12. 40 CFR 90.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine intake air humidity measurement... Emission Test Equipment Provisions § 90.310 Engine intake air humidity measurement. This section refers to... for the engine intake air, the ambient test cell humidity measurement may be used. (a)...

  13. 40 CFR 90.310 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine intake air humidity measurement... Emission Test Equipment Provisions § 90.310 Engine intake air humidity measurement. This section refers to... for the engine intake air, the ambient test cell humidity measurement may be used. (a)...

  14. Motion.

    ERIC Educational Resources Information Center

    Brand, Judith, Ed.

    2002-01-01

    This issue of Exploratorium Magazine focuses on the topic of motion. Contents include: (1) "First Word" (Zach Tobias); (2) "Cosmic Collisions" (Robert Irion); (3) "The Mobile Cell" (Karen E. Kalumuck); (4) "The Paths of Paths" (Steven Vogel); (5) "Fragments" (Pearl Tesler); (6) "Moving Pictures" (Amy Snyder); (7) "Plants on the Go" (Katharine…

  15. Regular oscillations and random motion of glass microspheres levitated by a single optical beam in air

    DOE PAGES

    Moore, Jeremy; Martin, Leopoldo L.; Maayani, Shai; Kim, Kyu Hyun; Chandrahalim, Hengky; Eichenfield, Matt; Martin, Inocencio R.; Carmon, Tal

    2016-02-03

    We experimentally reporton optical binding of many glass particles in air that levitate in a single optical beam. A diversity of particle sizes and shapes interact at long range in a single Gaussian beam. Our system dynamics span from oscillatory to random and dimensionality ranges from 1 to 3D. In conclusion, the low loss for the center of mass motion of the beads could allow this system to serve as a standard many body testbed, similar to what is done today with atoms, but at the mesoscopic scale.

  16. Regular oscillations and random motion of glass microspheres levitated by a single optical beam in air.

    PubMed

    Moore, Jeremy; Martin, Leopoldo L; Maayani, Shai; Kim, Kyu Hyun; Chandrahalim, Hengky; Eichenfield, Matt; Martin, Inocencio R; Carmon, Tal

    2016-02-01

    We experimentally report on optical binding of many glass particles in air that levitate in a single optical beam. A diversity of particle sizes and shapes interact at long range in a single Gaussian beam. Our system dynamics span from oscillatory to random and dimensionality ranges from 1 to 3D. The low loss for the center of mass motion of the beads could allow this system to serve as a standard many body testbed, similar to what is done today with atoms, but at the mesoscopic scale.

  17. Measurement of vertical velocity using clear-air Doppler radars

    NASA Technical Reports Server (NTRS)

    Vanzandt, T. E.; Green, J. L.; Nastrom, G. D.; Gage, K. S.; Clark, W. L.; Warnock, J. M.

    1989-01-01

    A new clear air Doppler radar was constructed, called the Flatland radar, in very flat terrain near Champaign-Urbana, Illinois. The radar wavelength is 6.02 m. The radar has been measuring vertical velocity every 153 s with a range resolution of 750 m almost continuously since March 2, 1987. The variance of vertical velocity at Flatland is usually quite small, comparable to the variance at radars located near rough terrain during periods of small background wind. The absence of orographic effects over very flat terrain suggests that clear air Doppler radars can be used to study vertical velocities due to other processes, including synoptic scale motions and propagating gravity waves. For example, near rough terrain the shape of frequency spectra changes drastically as the background wind increases. But at Flatland the shape at periods shorter than a few hours changes only slowly, consistent with the changes predicted by Doppler shifting of gravity wave spectra. Thus it appears that the short period fluctuations of vertical velocity at Flatland are alsmost entirely due to the propagating gravity waves.

  18. Measuring intracellular motion in cancer cell using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Zam, Azhar; Kolios, Michael C.

    2016-03-01

    In this study, we demonstrate that OCT speckle decorrelation techniques can be used to probe intracellular motion in cancer cells. Spheroids and cell pellets were used as a model to probe intracellular motion. ZnCl2 was used to inhibit mitochondrial motion within the cells. The results reveal the changes in intracellular motion during the spheroid growth phase. Moreover, to modify the motion of mitochondria, cell pellet were exposed to ZnCl2, and agent known to o impair cellular energy production through inhibition of mitochondrial function. The speckle decorrelation time during the growth phase of spheroids decreased by 35 ms over 21 days and 25 ms during inhibition of mitochondrial motion 10 minutes after exposure to ZnCl2.

  19. Retrievals of Vertical Air Motion from the HIAPER Cloud Radar during CSET

    NASA Astrophysics Data System (ADS)

    Schwartz, M. C.; Ghate, V. P.; Vivekanandan, J.; Tsai, P.; Ellis, S. M.

    2015-12-01

    the ocean surface echoes, together with aircraft motion data, will be used to ameliorate the radar beam broadening due to aircraft motion. After accounting for the aircraft motion we will explore techniques to retrieve the vertical air motion and cloud microphysical variables from the radar Doppler spectrum.

  20. 40 CFR 89.326 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine intake air humidity measurement. 89.326 Section 89.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Test Equipment Provisions § 89.326 Engine intake air humidity measurement. (a) Humidity conditioned...

  1. 40 CFR 89.326 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air humidity measurement. 89.326 Section 89.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Test Equipment Provisions § 89.326 Engine intake air humidity measurement. (a) Humidity conditioned...

  2. 40 CFR 89.326 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine intake air humidity measurement. 89.326 Section 89.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Test Equipment Provisions § 89.326 Engine intake air humidity measurement. (a) Humidity conditioned...

  3. 40 CFR 89.326 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine intake air humidity measurement. 89.326 Section 89.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Test Equipment Provisions § 89.326 Engine intake air humidity measurement. (a) Humidity conditioned...

  4. 40 CFR 89.326 - Engine intake air humidity measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine intake air humidity measurement. 89.326 Section 89.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Test Equipment Provisions § 89.326 Engine intake air humidity measurement. (a) Humidity conditioned...

  5. Oscillatory motion based measurement method and sensor for measuring wall shear stress due to fluid flow

    DOEpatents

    Armstrong, William D.; Naughton, Jonathan; Lindberg, William R.

    2008-09-02

    A shear stress sensor for measuring fluid wall shear stress on a test surface is provided. The wall shear stress sensor is comprised of an active sensing surface and a sensor body. An elastic mechanism mounted between the active sensing surface and the sensor body allows movement between the active sensing surface and the sensor body. A driving mechanism forces the shear stress sensor to oscillate. A measuring mechanism measures displacement of the active sensing surface relative to the sensor body. The sensor may be operated under periodic excitation where changes in the nature of the fluid properties or the fluid flow over the sensor measurably changes the amplitude or phase of the motion of the active sensing surface, or changes the force and power required from a control system in order to maintain constant motion. The device may be operated under non-periodic excitation where changes in the nature of the fluid properties or the fluid flow over the sensor change the transient motion of the active sensor surface or change the force and power required from a control system to maintain a specified transient motion of the active sensor surface.

  6. Low frequency motion measurement and control of spacecrafts and satellites

    NASA Astrophysics Data System (ADS)

    Acernese, F.; Giordano, G.; Romano, R.; Barone, F.

    2015-04-01

    This paper describes a new mechanical application of the Watt-linkage for the development and implementation of mono-axial sensors aimed to low frequency motion measurement and control of spacecrafts and satellites. The basic component of these sensors is the one dimensional UNISA Folded Pendulum mechanical sensor, developed for ground-based applications, whose unique features are due to a very effective optimization of the effects of gravitational force on the folded pendulum mechanical components, that allowed the design and implementation of FP sensors compact (< 20 cm), light (< 300 g), scalable, tunable resonance frequency < 200mHz), with large band (10-6 Hz - 100Hz), high quality factor (Q > 15000 in vacuum at 1Hz), with good immunity to environmental noises and sensitivity, guaranteed by an integrated laser optical readout, and fully adaptable to the specific requirements of the application. In this paper we show how to extend the application of ground-based FP also to space, in absence of gravity, still keeping all the above interesting features and characteristics that make this class of sensors very effective in terms of large band, especially in the low frequency, sensitivity and long term reliability. Preliminary measurements on a prototype confirm the feasibility, showing also that very good performances can be relatively easily obtained.

  7. Quantitative viscoelastic parameters measured by harmonic motion imaging.

    PubMed

    Vappou, Jonathan; Maleke, Caroline; Konofagou, Elisa E

    2009-06-01

    Quantifying the mechanical properties of soft tissues remains a challenging objective in the field of elasticity imaging. In this work, we propose an ultrasound-based method for quantitatively estimating viscoelastic properties, using the amplitude-modulated harmonic motion imaging (HMI) technique. In HMI, an oscillating acoustic radiation force is generated inside the medium by using focused ultrasound and the resulting displacements are measured using an imaging transducer. The proposed approach is a two-step method that uses both the properties of the propagating shear wave and the phase shift between the applied stress and the measured strain in order to infer to the shear storage (G') and shear loss modulus (G''), which refer to the underlying tissue elasticity and viscosity, respectively. The proposed method was first evaluated on numerical phantoms generated by finite-element simulations, where a very good agreement was found between the input and the measured values of G' and G''. Experiments were then performed on three soft tissue-mimicking gel phantoms. HMI measurements were compared to rotational rheometry (dynamic mechanical analysis), and very good agreement was found at the only overlapping frequency (10 Hz) in the estimate of the shear storage modulus G' (14% relative error, averaged p-value of 0.34), whereas poorer agreement was found in G'' (55% relative error, averaged p-value of 0.0007), most likely due to the significantly lower values of G'' of the gel phantoms, posing thus a greater challenge in the sensitivity of the method. Nevertheless, this work proposes an original model-independent ultrasound-based elasticity imaging method that allows for direct, quantitative estimation of tissue viscoelastic properties, together with a validation against mechanical testing.

  8. Air density measurement with a falling A4 sheet

    NASA Astrophysics Data System (ADS)

    Oladyshkin, Ivan V.; Oladyshkina, Anastasia A.

    2016-09-01

    We propose a simple experiment on the air density measurement which does not require any special equipment: just an A4 sheet of paper, a stopwatch and a ruler. The discussed method uses the most basic air resistance model.

  9. A two-axis in-plane motion measurement system based on optical beam deflection

    SciTech Connect

    Sriramshankar, R.; Mrinalini, R. Sri Muthu; Jayanth, G. R.

    2013-10-15

    Measurement of in-plane motion with high resolution and large bandwidth enables model-identification and real-time control of motion-stages. This paper presents an optical beam deflection based system for measurement of in-plane motion of both macro- and micro-scale motion stages. A curved reflector is integrated with the motion stage to achieve sensitivity to in-plane translational motion along two axes. Under optimal settings, the measurement system is shown to theoretically achieve sub-angstrom measurement resolution over a bandwidth in excess of 1 kHz and negligible cross-sensitivity to linear motion. Subsequently, the proposed technique is experimentally demonstrated by measuring the in-plane motion of a piezo flexure stage and a scanning probe microcantilever. For the former case, reflective spherical balls of different radii are employed to measure the in-plane motion and the measured sensitivities are shown to agree with theoretical values, on average, to within 8.3%. For the latter case, a prototype polydimethylsiloxane micro-reflector is integrated with the microcantilever. The measured in-plane motion of the microcantilever probe is used to identify nonlinearities and the transient dynamics of the piezo-stage upon which the probe is mounted. These are subsequently compensated by means of feedback control.

  10. Air-bearing spin facility for measuring energy dissipation

    NASA Technical Reports Server (NTRS)

    Peterson, R. L.

    1976-01-01

    The air-bearing spin facility was developed to determine experimentally the effect of energy dissipation upon the motion of spinning spacecraft. The facility consists of an air-bearing spin table, a telemetry system, a command system, and a ground control station. The air-bearing spin table was designed to operate in a vacuum chamber. Tests were run on spacecraft components such as fuel tanks, nutation dampers, reaction wheels, and active nutation damper systems. Each of these items affected the attitude of a spinning spacecraft. An experimental approach to determine these effects was required because the dissipation of these components could not be adequately analyzed. The results of these experiments have been used, with excellent results, to predict spacecraft motion.

  11. Optimal ground motion intensity measure for long-period structures

    NASA Astrophysics Data System (ADS)

    Guan, Minsheng; Du, Hongbiao; Cui, Jie; Zeng, Qingli; Jiang, Haibo

    2015-10-01

    This paper aims to select the most appropriate ground motion intensity measure (IM) that is used in selecting earthquake records for the dynamic time history analysis of long-period structures. For this purpose, six reinforced concrete frame-core wall structures, designed according to modern seismic codes, are studied through dynamic time history analyses with a set of twelve selected earthquake records. Twelve IMs and two types of seismic damage indices, namely, the maximum seismic response-based and energy-based parameters, are chosen as the examined indices. Selection criteria such as correlation, efficiency, and proficiency are considered in the selection process. The optimal IM is identified by means of a comprehensive evaluation using a large number of data of correlation, efficiency, and proficiency coefficients. Numerical results illustrate that peak ground velocity is the optimal one for long-period structures and peak ground displacement is also a close contender. As compared to previous reports, the spectral-correlated parameters can only be taken as moderate IMs. Moreover, the widely used peak ground acceleration in the current seismic codes is considered inappropriate for long-period structures.

  12. Measuring response saturation in human MT and MST as a function of motion density.

    PubMed

    Durant, Szonya; Furlan, Michele

    2014-01-01

    The human brain areas MT and MST have been studied in great detail using fMRI with regards to their motion processing properties; however, to what extent this corresponds with single cell recordings remains to be fully described. Average response over human MT+ has been shown to increase linearly with motion coherence, similar to single cell responses. In response to motion density some single cell data however suggest a rapid saturation. We ask how the combination of these responses is reflected in the population response. We measured the blood oxygen level dependent (BOLD) response function of MT and MST using a motion density signal, comparing with area V1. We used spatially fixed apertures containing motion stimuli to manipulate the area covered by motion. We found that MT and MST responded above baseline to a very minimal amount of motion and showed a rather flat response to motion density, indicative of saturation. We discuss how this may be related to the size of the receptive fields and inhibitory interactions, although necessarily residual attention effects also need to be considered. We then compared different types of motion and found no difference between coherent and random motion at any motion density, suggesting that when combining response over several motion stimuli covering the visual field, a linear relationship of MT and MST population response as a function of motion coherence might not hold. PMID:25057944

  13. 40 CFR 91.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Intake air flow measurement specifications. 91.416 Section 91.416 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.416 Intake air flow...

  14. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Air flow measurement specifications. 89.414 Section 89.414 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Exhaust Emission Test Procedures § 89.414 Air...

  15. Motion of Optically Heated Spheres at the Water-Air Interface.

    PubMed

    Girot, A; Danné, N; Würger, A; Bickel, T; Ren, F; Loudet, J C; Pouligny, B

    2016-03-22

    A micrometer-sized spherical particle classically equilibrates at the water-air interface in partial wetting configuration, causing about no deformation to the interface. In condition of thermal equilibrium, the particle just undergoes faint Brownian motion, well visible under a microscope. We report experimental observations when the particle is made of a light-absorbing material and is heated up by a vertical laser beam. We show that, at small laser power, the particle is trapped in on-axis configuration, similarly to 2-dimensional trapping of a transparent sphere by optical forces. Conversely, on-axis trapping becomes unstable at higher power. The particle escapes off the laser axis and starts orbiting around the axis. We show that the laser-heated particle behaves as a microswimmer with velocities on the order of several 100 μm/s with just a few milliwatts of laser power. PMID:26916053

  16. 40 CFR 90.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine intake air temperature... Emission Test Equipment Provisions § 90.309 Engine intake air temperature measurement. (a) The measurement...) The temperature measurements must be accurate to within ±2 °C....

  17. 40 CFR 90.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine intake air temperature... Emission Test Equipment Provisions § 90.309 Engine intake air temperature measurement. (a) The measurement...) The temperature measurements must be accurate to within ±2 °C....

  18. 40 CFR 90.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine intake air temperature... Emission Test Equipment Provisions § 90.309 Engine intake air temperature measurement. (a) The measurement...) The temperature measurements must be accurate to within ±2 °C....

  19. 40 CFR 90.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air temperature... Emission Test Equipment Provisions § 90.309 Engine intake air temperature measurement. (a) The measurement...) The temperature measurements must be accurate to within ±2 °C....

  20. 40 CFR 90.309 - Engine intake air temperature measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine intake air temperature... Emission Test Equipment Provisions § 90.309 Engine intake air temperature measurement. (a) The measurement...) The temperature measurements must be accurate to within ±2 °C....

  1. Air exchange effectiveness in office buildings: Measurement techniques and results

    SciTech Connect

    Fisk, W.J.; Faulkner, D.

    1992-07-01

    We define two air exchange effectiveness parameters which indicate the extent of short circuiting, mixing, or displacement air flow in an entire building, the air diffusion effectiveness which indicates the air flow pattern locally, and the normalized local age of air. After describing two tracer gas procedures for measuring these parameters, we discuss assumptions inherent in the data analysis that are often violated in large office buildings. To obtain valuable data, careful selection of buildings for measurements and assessments to determine if operating conditions are reasonably consistent with the assumptions are necessary. Multiple factors, in addition to the air flow pattern in the occupied space, can affect measurement results, consequently, the interpretation of measurements is not straightforward. We summarize the results of measurements in several office buildings and in a research laboratory. Almost all measurements indicate that the extent of both short circuiting and displacement flow is small. A moderate amount of short circuiting is evident from a few measurements in rooms with heated supply air. Ages of air and their reciprocals (local ventilation rates) often vary substantially between rooms, probably because of room-to-room variation in the rate of air supply. For future research, we suggest assessments of measurement accuracy, development of measurement approaches that may be practically applied for a broader range of buildings, and a greater focus on pollutant removal efficiencies.

  2. Equipment for Measuring Air Flow, Air Temperature, Relative Humidity, and Carbon Dioxide in Schools. Technical Bulletin.

    ERIC Educational Resources Information Center

    Jacobs, Bruce W.

    Information on equipment and techniques that school facility personnel may use to evaluate IAQ conditions are discussed. Focus is placed on the IAQ parameters of air flow, air temperature, relative humidity, as well as carbon dioxide and the equipment used to measure these factors. Reasons for measurement and for when the measurement of these…

  3. Interexaminer reliability and concurrent validity of two instruments for the measurement of cervical ranges of motion.

    PubMed

    Zachman, Z J; Traina, A D; Keating, J C; Bolles, S T; Braun-Porter, L

    1989-06-01

    The reliability of measurement of cervical ranges of motion (ROM) has rarely been studied. The current study evaluated the interexaminer reliability and concurrent validity of two instruments (rangiometer and goniometer) for measuring cervical ranges of motion. Twenty-four consenting subjects were assigned to random orders of examiners, instruments and planes of motion. Thirteen measurements of cervical motion and neutral positions were evaluated by two examiners using each instrument. Interexaminer reliability coefficients were generally greater than interinstrument coefficients, and both were higher than a combination of interexaminer/interinstrument predictions. The r values for rangiometric objectivity were higher than those of the goniometer in 9 of 10 cervical ranges of motion. The rangiometer is a moderately reliable instrument for measuring cervical ranges of motion. PMID:2746145

  4. Measurement of Radon in Indoor Air.

    ERIC Educational Resources Information Center

    Downey, Daniel M.; Simolunas, Glenn

    1988-01-01

    Describes a laboratory experiment to teach the principles of air sampling, gamma ray spectroscopy, nuclear decay, and radioactive equilibrium. Analyzes radon by carbon adsorption and gamma ray counting. Provides methodology and rate of decay equations. (MVL)

  5. Gas bulk motion in the Perseus Cluster measured with Suzaku

    SciTech Connect

    Tamura, T.; Yamasaki, N. Y.; Iizuka, R.; Fukazawa, Y.; Hayashida, K.; Ueda, S.; Matsushita, K.; Sato, K.; Nakazawa, K.; Ota, N.; Takizawa, M.

    2014-02-10

    We present the results from Suzaku observations of the Perseus Cluster, which is relatively close, the brightest in the X-ray sky, and a relaxed object with a cool core. A number of exposures of central regions and offset pointing with the X-ray Imaging Spectrometer cover a region within radii of 20'-30'. The central data are used to evaluate the instrumental energy-scale calibration with accuracy confirmed to within around 300 km s{sup –1} by the spatial and temporal variation of the instruments. These deep and well-calibrated data are used to measure X-ray redshifts of the intracluster medium. A hint of gas bulk motion, with radial velocity of about –(150-300) km s{sup –1} relative to the main system, was found at 2'-4' (45-90 kpc) west of the cluster center, where an X-ray excess and a cold front were found previously. No other velocity structure was discovered. Over spatial scales of 50-100 kpc and within 200 kpc radii of the center, the gas-radial-velocity variation is below 300 km s{sup –1}, while over scales of 400 kpc within 600 kpc radii, the variation is below 600 km s{sup –1}. These X-ray redshift distributions are compared spatially with those of optical member galaxies for the first time in galaxy clusters. Based on X-ray line widths, gas turbulent velocities within these regions are also constrained within 1000-3000 km s{sup –1}. These results of gas dynamics in the core and larger scales in association with cluster merger activities are discussed, and the future potential of high-energy resolution spectroscopy with ASTRO-H is considered.

  6. Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph.

    PubMed

    Warren, Kristen M; Harvey, Joshua R; Chon, Ki H; Mendelson, Yitzhak

    2016-01-01

    Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information during simple, repetitive motion, leading to differences in motion tolerance across channels. In this paper, we investigate the performance of a custom-built multichannel forehead-mounted photoplethysmographic sensor under a variety of intense motion artifacts. We introduce an advanced multichannel template-matching algorithm that chooses the channel with the least motion artifact to calculate PR for each time instant. We show that for a wide variety of random motion, channels respond differently to motion artifacts, and the multichannel estimate outperforms single-channel estimates in terms of motion tolerance, signal quality, and PR errors. We have acquired 31 data sets consisting of PPG waveforms corrupted by random motion and show that the accuracy of PR measurements achieved was increased by up to 2.7 bpm when the multichannel-switching algorithm was compared to individual channels. The percentage of PR measurements with error ≤ 5 bpm during motion increased by 18.9% when the multichannel switching algorithm was compared to the mean PR from all channels. Moreover, our algorithm enables automatic selection of the best signal fidelity channel at each time point among the multichannel PPG data. PMID:26959034

  7. Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph

    PubMed Central

    Warren, Kristen M.; Harvey, Joshua R.; Chon, Ki H.; Mendelson, Yitzhak

    2016-01-01

    Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information during simple, repetitive motion, leading to differences in motion tolerance across channels. In this paper, we investigate the performance of a custom-built multichannel forehead-mounted photoplethysmographic sensor under a variety of intense motion artifacts. We introduce an advanced multichannel template-matching algorithm that chooses the channel with the least motion artifact to calculate PR for each time instant. We show that for a wide variety of random motion, channels respond differently to motion artifacts, and the multichannel estimate outperforms single-channel estimates in terms of motion tolerance, signal quality, and PR errors. We have acquired 31 data sets consisting of PPG waveforms corrupted by random motion and show that the accuracy of PR measurements achieved was increased by up to 2.7 bpm when the multichannel-switching algorithm was compared to individual channels. The percentage of PR measurements with error ≤ 5 bpm during motion increased by 18.9% when the multichannel switching algorithm was compared to the mean PR from all channels. Moreover, our algorithm enables automatic selection of the best signal fidelity channel at each time point among the multichannel PPG data. PMID:26959034

  8. Simultaneous detection of rotational and translational motion in optical tweezers by measurement of backscattered intensity.

    PubMed

    Roy, Basudev; Bera, Sudipta K; Banerjee, Ayan

    2014-06-01

    We describe a simple yet powerful technique of simultaneously measuring both translational and rotational motion of mesoscopic particles in optical tweezers by measuring the backscattered intensity on a quadrant photodiode (QPD). While the measurement of translational motion by taking the difference of the backscattered intensity incident on adjacent quadrants of a QPD is well known, we demonstrate that rotational motion can be measured very precisely by taking the difference between the diagonal quadrants. The latter measurement eliminates the translational component entirely and leads to a detection sensitivity of around 50 mdeg at S/N of 2 for angular motion of a driven microrod. The technique is also able to resolve the translational and rotational Brownian motion components of the microrod in an unperturbed trap and can be very useful in measuring translation-rotation coupling of micro-objects induced by hydrodynamic interactions.

  9. Particle motion measured at an operational wind turbine in relation to hearing sensitivity in fish.

    PubMed

    Sigray, Peter; Andersson, Mathias H

    2011-07-01

    The effect of sound pressure on the hearing of fish has been extensively investigated in laboratory studies as well as in field trials in contrast to particle motion where few studies have been carried out. To improve this dearth of knowledge, an instrument for measuring particle motion was developed and used in a field trial. The particle motion is measured using a neutrally buoyant sphere, which co-oscillates with the fluid motion. The unit was deployed in close vicinity to a wind turbine foundation at Utgrunden wind farm in the Baltic Sea. Measurements of particle motion were undertaken at different distances from the turbine as well as at varying wind speeds. Levels of particle motion were compared to audiograms for cod (Gadus morhua L.) and plaice (Pleuronectes platessa L.).

  10. GRMPY surface ground motion measurements in Area 16

    SciTech Connect

    Deupree, R.G.

    1995-09-01

    The GRMPY surface ground motion data collection system was fielded on two shallowly buried high explosive tests in Area 16 at the Nevada Tests Site. Excellent data were collected on both tests and on two very small high explosive calibration tests conducted prior to the main tests. The data superficially resemble surface ground motion data for nuclear weapons tests, but there are differences. The most obvious is the rate of decline in peak vertical velocity with horizontal distance. Less obvious is the ratio of the surface ground zero peak vertical acceleration to the surface ground zero peak vertical velocity. The ramifications of these features as tools for on-site verification are explored.

  11. A comparative study on the effects of air gap wind and walking motion on the thermal properties of Arabian Thawbs and Chinese Cheongsams.

    PubMed

    Cui, Zhiying; Fan, Jintu; Wu, Yuenshing

    2016-08-01

    This paper reports on an experimental investigation on the effects of air gap, wind and walking motion on the thermal properties of traditional Arabian thawbs and Chinese cheongsams. Total thermal resistance (It) and vapour resistance (Re) were measured using the sweating fabric manikin - 'Walter', and the air gap volumes of the garments were determined by a 3D body scanner. The results showed the relative changes of It and Re of thawbs due to wind and walking motion are greater than those of cheongsams, which provided an explanation of why thawbs are preferred in extremely hot climate. It is further shown that thermal insulation and vapour resistance of thawbs increase with the air gap volume up to about 71,000 cm(3) and then decrease gradually. Thawbs with higher air permeability have significantly lower evaporative resistance particularly under windy conditions demonstrating the advantage of air permeable fabrics in body cooling in hot environments. Practitioner Summary: This paper aims to better understand the thermal insulation and vapour resistance of traditional Arabian thawbs and Chinese cheongsams, and the relationship between the thermal properties and their fit and design. The results of this study provide a scientific basis for designing ethnic clothing used in hot environments.

  12. Calibration of a system for measuring low air flow velocity in a wind tunnel

    NASA Astrophysics Data System (ADS)

    Krach, Andrzej; Kruczkowski, Janusz

    2016-08-01

    This article presents the calibration of a system for measuring air flow velocity in a wind tunnel with a multiple-hole orifice. The comparative method was applied for the calibration. The method consists in equalising the air flow velocity in a test section of the tunnel with that of the hot-wire anemometer probe which should then read zero value. The hot-wire anemometer probe moves reciprocally in the tunnel test section with a constant velocity, aligned and opposite to the air velocity. Air velocity in the tunnel test section is adjusted so that the minimum values of a periodic hot-wire anemometer signal displayed on an oscilloscope screen reach the lowest position (the minimum method). A sinusoidal component can be superimposed to the probe constant velocity. Then, the air flow velocity in the tunnel test section is adjusted so that, when the probe moves in the direction of air flow, only the second harmonic of the periodically variable velocity superimposed on the constant velocity (second harmonic method) remains at the output of the low-pass filter to which the hot-wire anemometer signal, displayed on the oscilloscope screen, is supplied. The velocity of the uniform motion of the hot-wire anemometer probe is measured with a magnetic linear encoder. The calibration of the system for the measurement of low air velocities in the wind tunnel was performed in the following steps: 1. Calibration of the linear encoder for the measurement of the uniform motion velocity of the hot-wire anemometer probe in the test section of the tunnel. 2. Calibration of the system for measurement of low air velocities with a multiple-hole orifice for the velocities of 0.1 and 0.25 m s-1: - (a) measurement of the probe movement velocity setting; - (b) measurement of air velocity in the tunnel test section with comparison according to the second harmonic method; - (c) measurement of air velocity in the tunnel with comparison according to the minimum method. The calibration

  13. Calibration of a system for measuring low air flow velocity in a wind tunnel

    NASA Astrophysics Data System (ADS)

    Krach, Andrzej; Kruczkowski, Janusz

    2016-08-01

    This article presents the calibration of a system for measuring air flow velocity in a wind tunnel with a multiple-hole orifice. The comparative method was applied for the calibration. The method consists in equalising the air flow velocity in a test section of the tunnel with that of the hot-wire anemometer probe which should then read zero value. The hot-wire anemometer probe moves reciprocally in the tunnel test section with a constant velocity, aligned and opposite to the air velocity. Air velocity in the tunnel test section is adjusted so that the minimum values of a periodic hot-wire anemometer signal displayed on an oscilloscope screen reach the lowest position (the minimum method). A sinusoidal component can be superimposed to the probe constant velocity. Then, the air flow velocity in the tunnel test section is adjusted so that, when the probe moves in the direction of air flow, only the second harmonic of the periodically variable velocity superimposed on the constant velocity (second harmonic method) remains at the output of the low-pass filter to which the hot-wire anemometer signal, displayed on the oscilloscope screen, is supplied. The velocity of the uniform motion of the hot-wire anemometer probe is measured with a magnetic linear encoder. The calibration of the system for the measurement of low air velocities in the wind tunnel was performed in the following steps: 1. Calibration of the linear encoder for the measurement of the uniform motion velocity of the hot-wire anemometer probe in the test section of the tunnel. 2. Calibration of the system for measurement of low air velocities with a multiple-hole orifice for the velocities of 0.1 and 0.25 m s‑1: - (a) measurement of the probe movement velocity setting; - (b) measurement of air velocity in the tunnel test section with comparison according to the second harmonic method; - (c) measurement of air velocity in the tunnel with comparison according to the minimum method. The calibration

  14. Perfluorocarbon tracer method for air-infiltration measurements

    DOEpatents

    Dietz, R.N.

    1982-09-23

    A method of measuring air infiltration rates suitable for use in rooms of homes and buildings comprises the steps of emitting perfluorocarbons in the room to be measured, sampling the air containing the emitted perfluorocarbons over a period of time, and analyzing the samples at a laboratory or other facility.

  15. Technique for Measuring Speed and Visual Motion Sensitivity in Lizards

    ERIC Educational Resources Information Center

    Woo, Kevin L.; Burke, Darren

    2008-01-01

    Testing sensory characteristics on herpetological species has been difficult due to a range of properties related to physiology, responsiveness, performance ability, and the type of reinforcer used. Using the Jacky lizard as a model, we outline a successfully established procedure in which to test the visual sensitivity to motion characteristics.…

  16. Precise Measurement of Velocity Dependent Friction in Rotational Motion

    ERIC Educational Resources Information Center

    Alam, Junaid; Hassan, Hafsa; Shamim, Sohaib; Mahmood, Waqas; Anwar, Muhammad Sabieh

    2011-01-01

    Frictional losses are experimentally determined for a uniform circular disc exhibiting rotational motion. The clockwise and anticlockwise rotations of the disc, that result when a hanger tied to a thread is released from a certain height, give rise to vertical oscillations of the hanger as the thread winds and unwinds over a pulley attached to the…

  17. Measurement of storage ring motion at the advanced light source

    SciTech Connect

    Krebs, G.F.

    1997-05-01

    The mechanical stability of the Advanced Light Source storage ring is examined over a period of 1.5 years from the point of view of floor motion. The storage ring beam position monitor stability is examined under various operating conditions.

  18. Evaluation of structure from motion for soil microtopography measurement

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Recent developments in low cost structure from motion (SFM) technologies offer new opportunities for geoscientists to acquire high resolution soil microtopography data at a fraction of the cost of conventional techniques. However, these new methodologies often lack easily accessible error metrics an...

  19. GAS CHROMATOGRAPHIC TECHNIQUES FOR THE MEASUREMENT OF ISOPRENE IN AIR

    EPA Science Inventory

    The chapter discusses gas chromatographic techniques for measuring isoprene in air. Such measurement basically consists of three parts: (1) collection of sufficient sample volume for representative and accurate quantitation, (2) separation (if necessary) of isoprene from interfer...

  20. Next-generation air measurement technologies

    EPA Science Inventory

    This is a presentation at a workshop in Chicago on emerging air monitoring technologies, hosted by a local nonprofit. The audience is composed of a mixture of technical backgrounds. This presentation will be part of an opening panel and the goal is to give an overview of the st...

  1. Drift motion of the magnetic monopole of Poljakov-'t Hooft in the air and the ball-lightning phenomenon

    SciTech Connect

    Korshunov, V.K. )

    1990-08-30

    In this paper by virtue of theoretical investigations of V. Rubakov on nucleons and nuclei decay with monopole-nucleon interaction, a qualitative analysis of the drift motion of the mon in the air is conducted. The physical picture obtained coincided in detail with the descriptions of the ball-lightning, for which reason ball- lightning is considered evidence for the magnetic monopole.

  2. Novel Assessment of Renal Motion in Children as Measured via Four-Dimensional Computed Tomography

    SciTech Connect

    Pai Panandiker, Atmaram S.; Sharma, Shelly; Naik, Mihir H.; Wu, Shengjie; Hua, Chiaho; Beltran, Chris; Krasin, Matthew J.; Merchant, Thomas E.

    2012-04-01

    Objectives: Abdominal intensity-modulated radiation therapy and proton therapy require quantification of target and organ motion to optimize localization and treatment. Although addressed in adults, there is no available literature on this issue in pediatric patients. We assessed physiologic renal motion in pediatric patients. Methods and Materials: Twenty free-breathing pediatric patients at a median age of 8 years (range, 2-18 years) with intra-abdominal tumors underwent computed tomography simulation and four-dimensional computed tomography acquisition (slice thickness, 3 mm). Kidneys and diaphragms were contoured during eight phases of respiration to estimate center-of-mass motion. We quantified center of kidney mass mobility vectors in three dimensions: anteroposterior (AP), mediolateral (ML), and superoinferior (SI). Results: Kidney motion decreases linearly with decreasing age and height. The 95% confidence interval for the averaged minima and maxima of renal motion in children younger than 9 years was 5-9 mm in the ML direction, 4-11 mm in the AP direction, and 12-25 mm in the SI dimension for both kidneys. In children older than 9 years, the same confidence interval reveals a widening range of motion that was 5-16 mm in the ML direction, 6-17 mm in the AP direction, and 21-52 mm in the SI direction. Although not statistically significant, renal motion correlated with diaphragm motion in older patients. The correlation between diaphragm motion and body mass index was borderline (r = 0.52, p = 0.0816) in younger patients. Conclusions: Renal motion is age and height dependent. Measuring diaphragmatic motion alone does not reliably quantify pediatric renal motion. Renal motion in young children ranges from 5 to 25 mm in orientation-specific directions. The vectors of motion range from 5 to 52 mm in older children. These preliminary data represent novel analyses of pediatric intra-abdominal organ motion.

  3. Determination of the linear equations of position-sensing detectors for small motion measurement systems.

    PubMed

    Liu, Chien-Sheng; Lin, Psang Dain

    2010-11-01

    Small motion measurement systems are widely used in industry measurement fields to measure small positional/angular motions. These systems usually consist of two parts: a measuring assembly and a reference assembly. The position-sensing detectors (PSDs) are embedded in either measuring assembly or reference assembly to sense the variations of laser light incidence points when there are any small positional/angular motions. To use these systems, it is necessary to determine the linear equations of PSD readings, which relate the six-degrees-of-freedom small positional/angular motions and PSD readings. The purpose of this paper is to derive these equations based on the paraxial raytracing method. Two measurement systems are used as illustrative examples to validate the proposed methodology. The methodology of this study will be useful for system design of PSD-based measurement systems and their applications. PMID:21045913

  4. Measure Guideline: Air Sealing Attics in Multifamily Buildings

    SciTech Connect

    Otis, C.; Maxwell, S.

    2012-06-01

    This Building America Measure Guideline is intended for owners, builders, contractors, homeowners, and other stakeholders in the multifamily building industry, and focuses on challenges found in existing buildings for a variety of housing types. It explains why air sealing is desirable, explores related health and safety issues, and identifies common air leakage points in multifamily building attics. In addition, it also gives an overview of materials and techniques typically used to perform air sealing work.

  5. Measure Guideline. Air Sealing Attics in Multifamily Buildings

    SciTech Connect

    Otis, Casey; Maxwell, Sean

    2012-06-01

    This Building America Measure Guideline is intended for owners, builders, contractors, homeowners, and other stakeholders in the multifamily building industry, and focuses on challenges found in existing buildings for a variety of housing types. It explains why air sealing is desirable, explores related health and safety issues, and identifies common air leakage points in multifamily building attics. In addition, it also gives an overview of materials and techniques typically used to perform air sealing work.

  6. The effect of motion on IMRT - looking at interplay with 3D measurements

    NASA Astrophysics Data System (ADS)

    Thomas, A.; Yan, H.; Oldham, M.; Juang, T.; Adamovics, J.; Yin, F. F.

    2013-06-01

    Clinical recommendations to address tumor motion management have been derived from studies dealing with simulations and 2D measurements. 3D measurements may provide more insight and possibly alter the current motion management guidelines. This study provides an initial look at true 3D measurements involving leaf motion deliveries by use of a motion phantom and the PRESAGE/DLOS dosimetry system. An IMRT and VMAT plan were delivered to the phantom and analyzed by means of DVHs to determine whether the expansion of treatment volumes based on known imaging motion adequately cover the target. DVHs confirmed that for these deliveries the expansion volumes were adequate to treat the intended target although further studies should be conducted to allow for differences in parameters that could alter the results, such as delivery dose and breathe rate.

  7. The effect of object motion in Fraunhofer holography with application to velocity measurements

    NASA Technical Reports Server (NTRS)

    Dotson, W. P., Jr.

    1970-01-01

    Experimental results extend the Fraunhofer holography theory to include moving objects. Conclusions indicate objects may move up to ten times their mean diameter during observation time. Their motion produces fringe patterns descriptive of that motion from which it is possible to reconstruct the hologram and measure the velocity.

  8. Proton dose calculation based on in-air fluence measurements.

    PubMed

    Schaffner, Barbara

    2008-03-21

    Proton dose calculation algorithms--as well as photon and electron algorithms--are usually based on configuration measurements taken in a water phantom. The exceptions to this are proton dose calculation algorithms for modulated scanning beams. There, it is usual to measure the spot profiles in air. We use the concept of in-air configuration measurements also for scattering and uniform scanning (wobbling) proton delivery techniques. The dose calculation includes a separate step for the calculation of the in-air fluence distribution per energy layer. The in-air fluence calculation is specific to the technique and-to a lesser extent-design of the treatment machine. The actual dose calculation uses the in-air fluence as input and is generic for all proton machine designs and techniques. PMID:18367787

  9. Automated digital motion-video abstraction - A fuzzy measure approach

    NASA Technical Reports Server (NTRS)

    Leigh, Albert B.; Pal, Sankar K.

    1992-01-01

    This paper addresses a solution to the problem of scene estimation of motion video data in the fuzzy set theoretic framework. Using fuzzy image feature extractors, a new algorithm is developed to compute the change of information in each of two successive frames to classify scenes. This classification process of raw input visual data can be used to establish structure for correlation. The algorithm attempts to fulfill the need for non-linear, frame-accurate access to video data for applications such as video editing and visual document archival/retrieval systems in multimedia environments.

  10. Measuring Three-Dimensional Thorax Motion Via Biplane Radiographic Imaging: Technique and Preliminary Results.

    PubMed

    Baumer, Timothy G; Giles, Joshua W; Drake, Anne; Zauel, Roger; Bey, Michael J

    2016-01-01

    Measures of scapulothoracic motion are dependent on accurate imaging of the scapula and thorax. Advanced radiographic techniques can provide accurate measures of scapular motion, but the limited 3D imaging volume of these techniques often precludes measurement of thorax motion. To overcome this, a thorax coordinate system was defined based on the position of rib pairs and then compared to a conventional sternum/spine-based thorax coordinate system. Alignment of the rib-based coordinate system was dependent on the rib pairs used, with the rib3:rib4 pairing aligned to within 4.4 ± 2.1 deg of the conventional thorax coordinate system.

  11. Errors in using two dimensional methods to measure motion about an offset revolute

    SciTech Connect

    Hollerbach, K.; Hollister, A.

    1996-03-01

    2D measurement of human joint motion involves analysis of 3D displacements in an observer selected measurement plane. Accurate marker placement and alignment of joint motion plane with the observer plane are difficult. Alignment of the two planes is essential for accurate recording and understanding of the joint mechanism and the movement about it. In nature, joint axes can exist at any orientation and location relative to a global reference frame. An aritrary axis is any axis that is not coincident with a reference coordinate. We calculate the errors resulting from measuring joint motion about an arbitrary axis using 2D methods.

  12. Doppler shift and ambiguity velocity caused by relative motion in quantum-enhanced measurement.

    PubMed

    Shen, Yanghe; Xu, Luping; Zhang, Hua; Yang, Peng

    2015-07-13

    We study the effect of relative motion on a frequency-entangled-based ranging scheme. Two major puzzles arise, i.e., Doppler shift and ambiguity velocity. During condition of rapid relative motion, Doppler shift invalidates the measurement result of this scheme; while during condition of slow relative motion, the ambiguity velocity turns into a major limitation. If relative speed between targets and measurement platform exceeds the ambiguity velocity, an accumulated profile obtained by the coincidence measurement will be distorted, which causes a lower ranging accuracy. Theoretical analysis shows a time-varying delay can be introduced to solve the two major puzzles. PMID:26191903

  13. 40 CFR 90.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Intake air flow measurement specifications. 90.416 Section 90.416 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test Procedures §...

  14. Optical Air Flow Measurements in Flight

    NASA Technical Reports Server (NTRS)

    Bogue, Rodney K.; Jentink, Henk W.

    2004-01-01

    This document has been written to assist the flight-test engineer and researcher in using optical flow measurements in flight applications. The emphasis is on describing tradeoffs in system design to provide desired measurement performance as currently understood. Optical system components are discussed with examples that illustrate the issues. The document concludes with descriptions of optical measurement systems designed for a variety of applications including aeronautics research, airspeed measurement, and turbulence hazard detection. Theoretical discussion is minimized, but numerous references are provided to supply ample opportunity for the reader to understand the theoretical underpinning of optical concepts.

  15. Measuring the Effects of Lift and Drag on Projectile Motion

    ERIC Educational Resources Information Center

    Cross, Rod

    2012-01-01

    The trajectory of a projectile through the air is affected both by gravity and by aerodynamic forces. The latter forces can conveniently be ignored in many situations, even when they are comparatively large. For example, if a 145-g, 74-mm diameter baseball is pitched at 40 ms[superscript -1] (89.5 mph), it experiences a drag force of about 1.5 N.…

  16. Relationship of area postrema to three putative measures of motion sickness

    NASA Technical Reports Server (NTRS)

    Sutton, R.; Fox, Robert A.; Daunton, Nancy G.

    1991-01-01

    Although the rat has an incomplete emetic reflex, several species-specific responses to motion were proposed as measures of 'motion sickness' in rats. The purpose was to determine the dependence of these responses on one of several neural structures known to be essential to motion-induced vomiting in species with a complete emetic reflex. The Area Postrema (AP) was shown to play an important role in the production of motion sickness in vomiting species. The effects of thermo-cautery ablations of the AP on three different responses supposedly reflecting motion sickness in the rat were compared: conditioned taste aversion (CTA); drinking suppression; and fecal boli. Efficacy of the ablations was determined by subjecting ablated, sham-operated, and unoperated control animals to a CTA test which is known to require a functional AP. Animals with AP ablations failed to form CTA when 0.15 M LiCl was paired with a 10 percent sucrose solution, while sham-operated control subjects conditioned as well as the unoperated control subjects. The extent of the ablations was evaluated histologically at the end of the experiment. To determine the effects of the ablations on the measures of motion sickness, all animals were subjected to rotation for 30 min or 90 min on a platform displaced 20 deg from earth horizontal. Results indicate that ablation of AP in the rat has no effect on the formation of CTA to a 4 percent solution of cider paired with motion, on the suppression of drinking immediately after exposure to motion, or on the frequency of fecal boli during exposure to motion. This failure of AP ablations to eliminate the effects of motion on any of these responses discourages their use as equivalents of motion-induced vomiting. The appropriateness of other suggested measures, e.g., pica, remains untested but the dependence of such measures on stimulation more severe than commonly used in motion sickness research and the absence of a demonstration of their dependence on neural

  17. AIR INFILTRATION MEASUREMENTS USING TRACER GASES: A LITERATURE REVIEW

    EPA Science Inventory

    The report gives results of a literature review of air filtration measurements using tracer gases, including sulfur hexafluoride, hydrogen, carbon monoxide, carbon dioxide, nitrous oxide, and radioactive argon and krypton. Sulfur hexafluoride is the commonest tracer gas of choice...

  18. Bronchoscopy guidance system based on bronchoscope-motion measurements

    NASA Astrophysics Data System (ADS)

    Cornish, Duane C.; Higgins, William E.

    2012-02-01

    Bronchoscopy-guidance systems assist physicians during bronchoscope navigation. However, these systems require an attending technician and fail to continuously track the bronchoscope. We propose a real-time technicianfree bronchoscopy-guidance system that employs continuous tracking. For guidance, our system presents directions on virtual views that are generated from the bronchoscope's tracked location. The system achieves bronchoscope tracking using a strategy that is based on a recently proposed method for sensor-based bronchoscope-motion tracking.1 Furthermore, a graphical indicator notifies the physician when he/she has maneuvered the bronchoscope to an incorrect branch. Our proposed system uses the sensor data to generate virtual views through multiple candidate routes and employs image matching in a Bayesian framework to determine the most probable bronchoscope pose. Tests based on laboratory phantoms validate the potential of the system.

  19. Intrinsic feature-based pose measurement for imaging motion compensation

    DOEpatents

    Baba, Justin S.; Goddard, Jr., James Samuel

    2014-08-19

    Systems and methods for generating motion corrected tomographic images are provided. A method includes obtaining first images of a region of interest (ROI) to be imaged and associated with a first time, where the first images are associated with different positions and orientations with respect to the ROI. The method also includes defining an active region in the each of the first images and selecting intrinsic features in each of the first images based on the active region. Second, identifying a portion of the intrinsic features temporally and spatially matching intrinsic features in corresponding ones of second images of the ROI associated with a second time prior to the first time and computing three-dimensional (3D) coordinates for the portion of the intrinsic features. Finally, the method includes computing a relative pose for the first images based on the 3D coordinates.

  20. Glacial isostatic adjustment of the British Isles: new constraints from GPS measurements of crustal motion

    NASA Astrophysics Data System (ADS)

    Bradley, S. L.; Milne, G. A.; Teferle, F. N.; Bingley, R. M.; Orliac, E. J.

    2009-07-01

    We compared estimates of crustal velocities within Great Britain based on continuous global positioning system (CGPS) measurements to predictions from a model of glacial isostatic adjustment (GIA). The observed and predicted values for vertical motion are highly correlated indicating that GIA is the dominant geodynamic process contributing to this field. In contrast, motion of the Eurasian plate dominates the horizontal motion component. A model of plate motion was adopted to remove this signal in order to estimate intraplate horizontal motion associated with GIA. However, a coherent pattern of horizontal motion was not evident in the resulting velocity field. We adopted a recently published model of the British-Irish ice sheet to predict vertical crustal motion for a large number of spherically symmetric Earth viscosity models. Our results show that the adopted ice model is capable of producing a high-quality fit to the observations. The CGPS-derived estimates of vertical motion provide a useful constraint on the average value of viscosity within the upper mantle. Values of model lithospheric thickness and lower mantle viscosity are less well resolved, however. A suite of predictions based on an alternative ice model indicates that the vertical motion data are relatively insensitive to uncertainties in the ice loading history and so the constraints on upper mantle viscosity are robust.

  1. Method and Apparatus for Measuring Surface Air Pressure

    NASA Technical Reports Server (NTRS)

    Lin, Bing (Inventor); Hu, Yongxiang (Inventor)

    2014-01-01

    The present invention is directed to an apparatus and method for remotely measuring surface air pressure. In one embodiment, the method of the present invention utilizes the steps of transmitting a signal having multiple frequencies into the atmosphere, measuring the transmitted/reflected signal to determine the relative received power level of each frequency and then determining the surface air pressure based upon the attenuation of the transmitted frequencies.

  2. Note: A resonating reflector-based optical system for motion measurement in micro-cantilever arrays

    SciTech Connect

    Sathishkumar, P.; Punyabrahma, P.; Sri Muthu Mrinalini, R.; Jayanth, G. R.

    2015-09-15

    A robust, compact optical measurement unit for motion measurement in micro-cantilever arrays enables development of portable micro-cantilever sensors. This paper reports on an optical beam deflection-based system to measure the deflection of micro-cantilevers in an array that employs a single laser source, a single detector, and a resonating reflector to scan the measurement laser across the array. A strategy is also proposed to extract the deflection of individual cantilevers from the acquired data. The proposed system and measurement strategy are experimentally evaluated and demonstrated to measure motion of multiple cantilevers in an array.

  3. Measuring In-Air and Underwater Hearing in Seabirds.

    PubMed

    Crowell, Sara C

    2016-01-01

    Electrophysiological methods were used to measure the in-air hearing of 10 species of seabirds. There are currently no measures of the underwater hearing abilities of diving birds. In preparation for constructing a behavioral audiogram both in-air and underwater hearing, several species of diving ducks were raised. Because there is a considerable amount of literature on bird hearing in air, the technical setup and training methods were modeled on similar studies, with modifications to address the nature of the underwater sound field and the difficulty of the task for the birds. PMID:26611081

  4. Measuring In-Air and Underwater Hearing in Seabirds.

    PubMed

    Crowell, Sara C

    2016-01-01

    Electrophysiological methods were used to measure the in-air hearing of 10 species of seabirds. There are currently no measures of the underwater hearing abilities of diving birds. In preparation for constructing a behavioral audiogram both in-air and underwater hearing, several species of diving ducks were raised. Because there is a considerable amount of literature on bird hearing in air, the technical setup and training methods were modeled on similar studies, with modifications to address the nature of the underwater sound field and the difficulty of the task for the birds.

  5. Determination of Foton M-2 satellite attitude motion by the data of microacceleration measurements

    NASA Astrophysics Data System (ADS)

    Beuselinck, T.; van Bavinchove, C.; Sazonov, V. V.; Chebukov, S. Yu.

    2009-12-01

    The results of reconstruction of uncontrolled attitude motion of the Foton M-2 satellite using measurements with the accelerometer TAS-3 are presented. The attitude motion of this satellite has been previously determined by the measurement data of the Earth’s magnetic field and the angular velocity. The TAS-3 data for this purpose are used for the first time. These data contain a well-pronounced additional component which made impossible their direct employment for the reconstruction of the attitude motion and whose origin was unknown several years ago. Later it has become known that the additional component is caused by the influence of the Earth’s magnetic field. The disclosure of this fact allowed us to take into account a necessary correction in processing of TAS-3 data and to use them for the reconstruction of the attitude motion of Foton M-2. Here, a modified method of processing TAS-3 data is described, as well as results of its testing and employing. The testing consisted in the direct comparison of the motion reconstructed by the new method with the motion constructed by the magnetic measurements. The new method allowed us to find the actual motion of Foton M-2 in the period June 9, 2005-June 14, 2005, when no magnetic measurements were carried out.

  6. Feasibility of Measuring Mean Vertical Motion for Estimating Advection. Chapter 6

    NASA Technical Reports Server (NTRS)

    Vickers, Dean; Mahrt, L.

    2005-01-01

    Numerous recent studies calculate horizontal and vertical advection terms for budget studies of net ecosystem exchange of carbon. One potential uncertainty in such studies is the estimate of mean vertical motion. This work addresses the reliability of vertical advection estimates by contrasting the vertical motion obtained from the standard practise of measuring the vertical velocity and applying a tilt correction, to the vertical motion calculated from measurements of the horizontal divergence of the flow using a network of towers. Results are compared for three different tilt correction methods. Estimates of mean vertical motion are sensitive to the choice of tilt correction method. The short-term mean (10 to 60 minutes) vertical motion based on the horizontal divergence is more realistic compared to the estimates derived from the standard practise. The divergence shows long-term mean (days to months) sinking motion at the site, apparently due to the surface roughness change. Because all the tilt correction methods rely on the assumption that the long-term mean vertical motion is zero for a given wind direction, they fail to reproduce the vertical motion based on the divergence.

  7. 40 CFR 92.108 - Intake and cooling air measurements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... device for all modes except idle. For idle, the measurement accuracy shall be ±5 percent or less of the...) Corrections to the measured air mass flowrate shall be made when an engine system incorporates devices that... from these devices shall be approved by the Administrator. (3) Measurements made in accordance with...

  8. Rural southeast Texas air quality measurements during the 2006 Texas Air Quality Study.

    PubMed

    Schade, Gunnar W; Khan, Siraj; Park, Changhyoun; Boedeker, Ian

    2011-10-01

    The authors conducted air quality measurements of the criteria pollutants carbon monoxide, nitrogen oxides, and ozone together with meteorological measurements at a park site southeast of College Station, TX, during the 2006 Texas Air Quality Study II (TexAQS). Ozone, a primary focus of the measurements, was above 80 ppb during 3 days and above 75 ppb during additional 8 days in summer 2006, suggestive of possible violations of the ozone National Ambient Air Quality Standard (NAAQS) in this area. In concordance with other air quality measurements during the TexAQS II, elevated ozone mixing ratios coincided with northerly flows during days after cold front passages. Ozone background during these days was as high as 80 ppb, whereas southerly air flows generally provided for an ozone background lower than 40 ppb. Back trajectory analysis shows that local ozone mixing ratios can also be strongly affected by the Houston urban pollution plume, leading to late afternoon ozone increases of as high as 50 ppb above background under favorable transport conditions. The trajectory analysis also shows that ozone background increases steadily the longer a southern air mass resides over Texas after entering from the Gulf of Mexico. In light of these and other TexAQS findings, it appears that ozone air quality is affected throughout east Texas by both long-range and regional ozone transport, and that improvements therefore will require at least a regionally oriented instead of the current locally oriented ozone precursor reduction policies.

  9. Optical Air Flow Measurements for Flight Tests and Flight Testing Optical Air Flow Meters

    NASA Technical Reports Server (NTRS)

    Jentink, Henk W.; Bogue, Rodney K.

    2005-01-01

    Optical air flow measurements can support the testing of aircraft and can be instrumental to in-flight investigations of the atmosphere or atmospheric phenomena. Furthermore, optical air flow meters potentially contribute as avionics systems to flight safety and as air data systems. The qualification of these instruments for the flight environment is where we encounter the systems in flight testing. An overview is presented of different optical air flow measurement techniques applied in flight and what can be achieved with the techniques for flight test purposes is reviewed. All in-flight optical airflow velocity measurements use light scattering. Light is scattered on both air molecules and aerosols entrained in the air. Basic principles of making optical measurements in flight, some basic optical concepts, electronic concepts, optoelectronic interfaces, and some atmospheric processes associated with natural aerosols are reviewed. Safety aspects in applying the technique are shortly addressed. The different applications of the technique are listed and some typical examples are presented. Recently NASA acquired new data on mountain rotors, mountain induced turbulence, with the ACLAIM system. Rotor position was identified using the lidar system and the potentially hazardous air flow profile was monitored by the ACLAIM system.

  10. 3D Measurement of Forearm and Upper Arm during Throwing Motion using Body Mounted Sensor

    NASA Astrophysics Data System (ADS)

    Koda, Hideharu; Sagawa, Koichi; Kuroshima, Kouta; Tsukamoto, Toshiaki; Urita, Kazutaka; Ishibashi, Yasuyuki

    The aim of this study is to propose the measurement method of three-dimensional (3D) movement of forearm and upper arm during pitching motion of baseball using inertial sensors without serious consideration of sensor installation. Although high accuracy measurement of sports motion is achieved by using optical motion capture system at present, it has some disadvantages such as the calibration of cameras and limitation of measurement place. Whereas the proposed method for 3D measurement of pitching motion using body mounted sensors provides trajectory and orientation of upper arm by the integration of acceleration and angular velocity measured on upper limb. The trajectory of forearm is derived so that the elbow joint axis of forearm corresponds to that of upper arm. Spatial relation between upper limb and sensor system is obtained by performing predetermined movements of upper limb and utilizing angular velocity and gravitational acceleration. The integration error is modified so that the estimated final position, velocity and posture of upper limb agree with the actual ones. The experimental results of the measurement of pitching motion show that trajectories of shoulder, elbow and wrist estimated by the proposed method are highly correlated to those from the motion capture system within the estimation error of about 10 [%].

  11. Polar motion from laser range measurements of GEOS-3

    NASA Technical Reports Server (NTRS)

    Schutz, B. E.; Tapley, B. D.; Ries, J.

    1979-01-01

    Using two-day arcs of GEOS-3 laser data, simultaneous solutions for pole position components, x sub p and y sub p, and orbit elements have been obtained for the period spanning 3 February to 6 March 1976 using three NASA Goddard Space Flight Center laser stations located near Washington, D.C. (STALAS) and on the islands of Bermuda and Grand Turk. The results are in general agreement with the BIH results. However, because of the locations of the laser sites, the x sub p solution is weaker than the y sub p solution. The x sub p and y sub p estimates were smoothed with a straight line by weighted least squares using the variance associated with the pole estimates as weights in order to reflect the effect of widely different data distributions. The smoothed y sub p differs by one meter with respect to the BIH smoothed values and the smoothed x sub p differs by about two meters. Spectral analysis of the results has identified frequencies associated with the orbital motion indicating the need for further improvements in the model of the physical system.

  12. Utilization of lasers for air data measurements

    NASA Astrophysics Data System (ADS)

    Hammer, J.

    1991-05-01

    The operating principles of the ALEV3 three axis laser Doppler anemometer, which was designed for flight tests with the A-320 and A-340 aircraft, are depicted. If mounted on the aircraft center of gravity, the ALEV-3 allows true flight velocity in three directions and angles of attack and sideslip to be directly measured with a very good accuracy, in particular flight areas such as limit buffeting, stall, high Mach numbers, or sideslip flights. Aircraft parameter estimation, calculation, and calibration results are presented. The accuracies of velocity, static pressure and aerodynamic angle measurements were compared with classical anemometers precisions. Flight tests results of the ALEV-1 one axis laser anemometer for A-320 are given as a reference.

  13. Measures and Relative Motions of Some Mostly F. G. W. Struve Doubles

    NASA Astrophysics Data System (ADS)

    Wiley, E. O.

    2012-04-01

    Measures of 59 pairs of double stars with long observational histories using "lucky imaging" techniques are reported. Relative motions of 59 pairs are investigated using histories of observation, scatter plots of relative motion, ordinary least-squares (OLS) and total proper motion analyses performed in "R," an open source programming language. A scatter plot of the coefficient of determinations derived from the OLS y|epoch and OLS x|epoch clearly separates common proper motion pairs from optical pairs and what are termed "long-period binary candidates." Differences in proper motion separate optical pairs from long-term binary candidates. An Appendix is provided that details how to use known rectilinear pairs as calibration pairs for the program REDUC.

  14. Measuring the Effects of Lift and Drag on Projectile Motion

    NASA Astrophysics Data System (ADS)

    Cross, Rod

    2012-02-01

    The trajectory of a projectile through the air is affected both by gravity and by aerodynamic forces. The latter forces can conveniently be ignored in many situations, even when they are comparatively large. For example, if a 145-g, 74-mm diameter baseball is pitched at 40 ms-1 (89.5 mph), it experiences a drag force of about 1.5 N. The gravitational force on the ball 1.42 N. Nevertheless, the trajectory of a baseball pitched without spin is not strongly affected by the drag force. Because the ball is relatively heavy and the flight distance is relatively small (about 60 ft), the drag force reduces the ball speed by only about 10% by the time it reaches the batter. As a result, the time taken for the ball to reach the batter is only about 5% longer than in a vacuum, and the actual trajectory is also very similar.2

  15. Motion measurement of SAR antenna based on high frame rate camera

    NASA Astrophysics Data System (ADS)

    Li, Q.; Cao, R.; Feng, H.; Xu, Z.

    2015-03-01

    Synthetic Aperture Radar (SAR) is currently in the marine, agriculture, geology and other fields are widely used, while the SAR antenna is one of the most important subsystems. Performance of antenna has a significant impact on the SAR sensitivity, azimuth resolution, image blur degree and other parameter. To improve SAR resolution, SAR antenna is designed and fabricated according to flexible expandable style. However, the movement of flexible antenna will have a greater impact on accuracy of SAR systems, so the motion measurement of the flexible antenna is an urgent problem. This paper studied motion measurements method based on high frame rate camera, designed and completed a flexible antenna motion measurement experiment. In the experiment the main IMU and the sub IMU were placed at both ends of the cantilever, which is simulation of flexible antenna, the high frame rate camera was placed above the main IMU, and the imaging target was set on side of the sub IMU. When the cantilever motion occurs, IMU acquired spatial coordinates of cantilever movement in real-time, and high frame rate camera captured a series of target images, and then the images was input into JTC to obtain the cantilever motion coordinates. Through the contrast and analysis of measurement results, the measurement accuracy of flexible antenna motion is verified.

  16. Direct and indirect measures of speech articulator motions using low power EM sensors

    SciTech Connect

    Barnes, T; Burnett, G; Gable, T; Holzrichter, J F; Ng, L

    1999-05-12

    Low power Electromagnetic (EM) Wave sensors can measure general properties of human speech articulator motions, as speech is produced. See Holzrichter, Burnett, Ng, and Lea, J.Acoust.Soc.Am. 103 (1) 622 (1998). Experiments have demonstrated extremely accurate pitch measurements (< 1 Hz per pitch cycle) and accurate onset of voiced speech. Recent measurements of pressure-induced tracheal motions enable very good spectra and amplitude estimates of a voiced excitation function. The use of the measured excitation functions and pitch synchronous processing enable the determination of each pitch cycle of an accurate transfer function and, indirectly, of the corresponding articulator motions. In addition, direct measurements have been made of EM wave reflections from articulator interfaces, including jaw, tongue, and palate, simultaneously with acoustic and glottal open/close signals. While several types of EM sensors are suitable for speech articulator measurements, the homodyne sensor has been found to provide good spatial and temporal resolution for several applications.

  17. Identification and influence of spatial outliers in air quality measurements

    NASA Astrophysics Data System (ADS)

    O'Leary, B. F.; Lemke, L. D.

    2015-12-01

    The heterogeneous nature of urban air complicates the analysis of spatial and temporal variability in air quality measurements. Evaluation of potentially inaccurate measurements (i.e., outliers) poses particularly difficult challenges in extensive air quality datasets with multiple measurements distributed in time and space. This study investigated the identification and impact of outliers in measurements of NO­2, BTEX, PM2.5, and PM10 in the contiguous Detroit, Michigan, USA and Windsor, Ontario, Canada international airshed. Measurements were taken at 100 locations during September 2008 and June 2009 and modeled at a 300m by 300m scale resolution. The objective was to determine if outliers were present and, if so, to quantify the magnitude of their impact on modeled spatial pollution distributions. The study built upon previous investigations by the Geospatial Determinants of Health Outcomes Consortium that examined relationships between air pollutant distributions and asthma exacerbations in the Detroit and Windsor airshed. Four independent approaches were initially employed to identify potential outliers: boxplots, variogram clouds, difference maps, and the Local Moran's I statistic. Potential outliers were subsequently reevaluated for consistency among methods and individually assessed to select a final set of outliers. The impact of excluding individual outliers was subsequently determined by revising the spatially variable air pollution models and recalculating associations between air contaminant concentrations and asthma exacerbations in Detroit and Windsor in 2008. For the pollutants examined, revised associations revealed weaker correlations with spatial outliers removed. Nevertheless, the approach employed improves the model integrity by increasing our understanding of the spatial variability of air pollution in the built environment and providing additional insights into the association between acute asthma exacerbations and air pollution.

  18. Sensitivity analysis of air gap motion with respect to wind load and mooring system for semi-submersible platform design

    NASA Astrophysics Data System (ADS)

    Huo, Fa-li; Nie, Yan; Yang, De-qing; Dong, Gang; Cui, Jin

    2016-07-01

    A design of semi-submersible platform is mainly based on the extreme response analysis due to the forces experienced by the components during lifetime. The external loads can induce the extreme air gap response and potential deck impact to the semi-submersible platform. It is important to predict air gap response of platforms accurately in order to check the strength of local structures which withstand the wave slamming due to negative air gap. The wind load cannot be simulated easily by model test in towing tank whereas it can be simulated accurately in wind tunnel test. Furthermore, full scale simulation of the mooring system in model test is still a tuff work especially the stiffness of the mooring system. Owing to the above mentioned problem, the model test results are not accurate enough for air gap evaluation. The aim of this paper is to present sensitivity analysis results of air gap motion with respect to the mooring system and wind load for the design of semi-submersible platform. Though the model test results are not suitable for the direct evaluation of air gap, they can be used as a good basis for tuning the radiation damping and viscous drag in numerical simulation. In the presented design example, a numerical model is tuned and validated by ANSYS AQWA based on the model test results with a simple 4 line symmetrical horizontal soft mooring system. According to the tuned numerical model, sensitivity analysis studies of air gap motion with respect to the mooring system and wind load are performed in time domain. Three mooring systems and five simulation cases about the presented platform are simulated based on the results of wind tunnel tests and sea-keeping tests. The sensitivity analysis results are valuable for the floating platform design.

  19. Measurement of transient force produced by a propagating arc magnetohydrodynamic plasma actuator in quiescent atmospheric air

    NASA Astrophysics Data System (ADS)

    Choi, Young Joon; Sirohi, Jayant; Raja, Laxminarayan L.

    2015-10-01

    An experimental study was conducted on a magnetohydrodynamic plasma actuator consisting of two parallel, six inch long, copper electrodes flush mounted on an insulating ceramic plate. An electrical arc is generated by a  ∼1 kA current pulse at  ∼100 V across the electrodes. A self-induced Lorentz force drives the arc along the electrodes. The motion of the arc induces flow in the surrounding air through compression as well as entrainment, and generates a transient force, about  ∼4 ms in duration. Experiments were performed on a prototype actuator in quiescent atmospheric air to characterize the motion of the arc and the momentum transferred to the surrounding air. Measurements included transient force and total impulse generated by the actuator as well as the armature voltage and current. The arc shape and transit velocity were determined by high-speed imaging. A peak force of 0.4 N imparting an impulse of 0.68 mN-s was measured for a peak current of 1.2 kA. The force scaled with the square of the armature current and the impulse scaled linearly with the spent capacitor energy. The results provide insight into the mechanisms of body force generation and momentum transfer of a magnetohydrodynamic plasma actuator.

  20. Measurement results obtained from air quality monitoring system

    SciTech Connect

    Turzanski, P.K.; Beres, R.

    1995-12-31

    An automatic system of air pollution monitoring operates in Cracow since 1991. The organization, assembling and start-up of the network is a result of joint efforts of the US Environmental Protection Agency and the Cracow environmental protection service. At present the automatic monitoring network is operated by the Provincial Inspection of Environmental Protection. There are in total seven stationary stations situated in Cracow to measure air pollution. These stations are supported continuously by one semi-mobile (transportable) station. It allows to modify periodically the area under investigation and therefore the 3-dimensional picture of creation and distribution of air pollutants within Cracow area could be more intelligible.

  1. Motion data classification on the basis of dynamic time warping with a cloud point distance measure

    NASA Astrophysics Data System (ADS)

    Switonski, Adam; Josinski, Henryk; Zghidi, Hafedh; Wojciechowski, Konrad

    2016-06-01

    The paper deals with the problem of classification of model free motion data. The nearest neighbors classifier which is based on comparison performed by Dynamic Time Warping transform with cloud point distance measure is proposed. The classification utilizes both specific gait features reflected by a movements of subsequent skeleton joints and anthropometric data. To validate proposed approach human gait identification challenge problem is taken into consideration. The motion capture database containing data of 30 different humans collected in Human Motion Laboratory of Polish-Japanese Academy of Information Technology is used. The achieved results are satisfactory, the obtained accuracy of human recognition exceeds 90%. What is more, the applied cloud point distance measure does not depend on calibration process of motion capture system which results in reliable validation.

  2. MEASUREMENT OF LOW LEVEL AIR TOXICS WITH MODIFIED UV DOAS

    EPA Science Inventory

    To further understand near source impacts, EPA is working to develop open-path optical techniques for spatiotemporal-resolved measurement of air pollutants. Of particular interest is near real time quantification of mobile-source generated CO, Nox and hydrocarbons measured in cl...

  3. The Aeroflex: A Bicycle for Mobile Air Quality Measurements

    PubMed Central

    Elen, Bart; Peters, Jan; Van Poppel, Martine; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout

    2013-01-01

    Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification. PMID:23262484

  4. The Aeroflex: a bicycle for mobile air quality measurements.

    PubMed

    Elen, Bart; Peters, Jan; Poppel, Martine Van; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout

    2013-01-01

    Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification. 

  5. Accurate and portable weigh-in-motion system for manifesting air cargo

    NASA Astrophysics Data System (ADS)

    Nodine, Robert N.; Scudiere, Matthew B.; Jordan, John K.

    1995-12-01

    An automated and portable weigh-in-motion system has been developed at Oak Ridge National Laboratory for the purpose of manifesting cargo onto aircraft. The system has an accuracy range of plus or minus 3.0% to plus or minus 6.0% measuring gross vehicle weight and locating the center of balance of moving vehicles at speeds of 1 to 5 mph. This paper reviews the control/user interface system and weight determination algorithm developed to acquire, process, and interpret multiple sensor inputs. The development effort resulted in a self- zeroing, user-friendly system capable of weighing a wide range of vehicles in any random order. The control system is based on the STANDARD (STD) bus and incorporates custom- designed data acquisition and sensor fusion hardware controlled by a personal computer (PC) based single-board computer. The user interface is written in the 'C' language to display number of axles, axle weight, axle spacing, gross weight, and center of balance. The weighing algorithm developed functions with any linear weight sensor and a set of four axle switches per sensor.

  6. Measuring contemporary crustal motions; NASA’s Crustal Dynamics Project

    USGS Publications Warehouse

    Frey, H. V.; Bosworth, J. M.

    1988-01-01

    In this article we describe briefly the two space geodetic techniques and how they are used by the Crustal Dynamics Project, show some of the very exciting results that have emerged at the halfway point in the project's life, describe the availability and utilization of the data being collected, and consider what the future may hold when measurement accuracies eventually exceed even those now available and when other international groups become more heavily involved.   

  7. Influence of detector motion in entanglement measurements with photons

    SciTech Connect

    Landulfo, Andre G. S.; Matsas, George E. A.; Torres, Adriano C.

    2010-04-15

    We investigate how the polarization correlations of entangled photons described by wave packets are modified when measured by moving detectors. For this purpose, we analyze the Clauser-Horne-Shimony-Holt Bell inequality as a function of the apparatus velocity. Our analysis is motivated by future experiments with entangled photons designed to use satellites. This is a first step toward the implementation of quantum information protocols in a global scale.

  8. Polarized radio emission from extensive air showers measured with LOFAR

    SciTech Connect

    Schellart, P.; Buitink, S.; Corstanje, A.; Enriquez, J.E.; Falcke, H.; Hörandel, J.R.; Krause, M.; Nelles, A.; Rachen, J.P.; Veen, S. ter; Thoudam, S.

    2014-10-01

    We present LOFAR measurements of radio emission from extensive air showers. We find that this emission is strongly polarized, with a median degree of polarization of nearly 99%, and that the angle between the polarization direction of the electric field and the Lorentz force acting on the particles, depends on the observer location in the shower plane. This can be understood as a superposition of the radially polarized charge-excess emission mechanism, first proposed by Askaryan and the geomagnetic emission mechanism proposed by Kahn and Lerche. We calculate the relative strengths of both contributions, as quantified by the charge-excess fraction, for 163 individual air showers. We find that the measured charge-excess fraction is higher for air showers arriving from closer to the zenith. Furthermore, the measured charge-excess fraction also increases with increasing observer distance from the air shower symmetry axis. The measured values range from (3.3± 1.0)% for very inclined air showers at 25 m to (20.3± 1.3)% for almost vertical showers at 225 m. Both dependencies are in qualitative agreement with theoretical predictions.

  9. Global Pressure Measurement of Unsteady-State Flow and Motion on Fluttering Airfoil

    NASA Astrophysics Data System (ADS)

    Okabe, Taika; Miyazaki, Takeshi; Saitoh, Kenichi; Sakaue, Hirotaka

    2012-11-01

    Pressure-sensitive paint (PSP) measurement has been applied to a fluid dynamic measurement. It can be applied to a steady-state flow in the transonic and supersonic wind tunnels. To extend the PSP measurement, an unsteady-state measurement is paid attention. It can be categorized by the unsteady-state flow and unsteady motion of the PSP-coated model. The former can be captured by using a porous PSP. The fastest PSP gives the response time on the order of ten microseconds. For the latter, the motion-capturing PSP method is studied to capture the unsteady motion. It consists of a two-color PSP and color camera. One color corresponds to the pressure-independent luminescence, and the other to the pressure-dependent luminescence. The former is used to cancel the pressure-independent distribution of a pressure-dependent image. The two-color images are simultaneously captured by the color camera. A combination of the unsteady-state flow and the motion can be occurred for an unsteady-state measurement. We present one of the cases, which is a flutter on an airfoil. By combining a porous PSP and the motion-capturing method, a pressure distribution on a fluttering airfoil (2-D YXX 30% span) is captured.

  10. Measuring Outdoor Air Intake Rates into Existing Building

    SciTech Connect

    Fisk, William; Sullivan, Douglas; Cohen, Sebastian; Han, Hwataik

    2009-04-16

    Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10 percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15 percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100 percent, and were often greater than 25 percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

  11. Low-frequency sound absorption measurements in air

    NASA Technical Reports Server (NTRS)

    Zuckerwar, A. J.; Meredith, R. W.

    1984-01-01

    Thirty sets of sound absorption measurements in air at a pressure of 1 atmosphere are presented at temperatures from 10 C to 50 C, relative humidities from 0 to 100 percent, and frequencies from 10 to 2500 Hz. The measurements were conducted by the method of free decay in a resonant tube having a length of 18.261 m and bore diameter of 0.152 m. Background measurements in a gas consisting of 89.5 percent N2 and 10.5 percent Ar, a mixture which has the same sound velocity as air, permitted the wall and structural losses of the tube to be separated from the constituent absorption, consisting of classical rotational and vibrational absorption, in the air samples. The data were used to evaluate the vibrational relaxation frequencies of N2 and/or O2 for each of the 30 sets of meteorological parameters. Over the full range of humidity, the measured relaxation frequencies of N2 in air lie between those specified by ANSI Standard S1.26-1978 and those measured earlier in binary N2H2O mixtures. The measured relaxation frequencies could be determined only at very low values of humidity, reveal a significant trend away from the ANSI standard, in agreement with a prior investigation.

  12. Measurement of oxygen transfer from air into organic solvents

    PubMed Central

    Ramesh, Hemalata; Hobisch, Mathias; Borisov, Sergey; Klimant, Ingo; Krühne, Ulrich; Woodley, John M

    2015-01-01

    Abstract BACKGROUND The use of non‐aqueous organic media is becoming increasingly important in many biotechnological applications in order to achieve process intensification. Such media can be used, for example, to directly extract poorly water‐soluble toxic products from fermentations. Likewise many biological reactions require the supply of oxygen, most normally from air. However, reliable online measurements of oxygen concentration in organic solvents (and hence oxygen transfer rates from air to the solvent) has to date proven impossible due to limitations in the current analytical methods. RESULTS For the first time, online oxygen measurements in non‐aqueous media using a novel optical sensor are demonstrated. The sensor was used to measure oxygen concentration in various organic solvents including toluene, THF, isooctane, DMF, heptane and hexane (which have all been shown suitable for several biological applications). Subsequently, the oxygen transfer rates from air into these organic solvents were measured. CONCLUSION The measurement of oxygen transfer rates from air into organic solvents using the dynamic method was established using the solvent resistant optical sensor. The feasibility of online oxygen measurements in organic solvents has also been demonstrated, paving the way for new opportunities in process control. © 2015 The Authors. Journal of Chemical Technology & Biotechnology published by JohnWiley & Sons Ltd on behalf of Society of Chemical Industry.

  13. Measurement of time delays in gated radiotherapy for realistic respiratory motions

    SciTech Connect

    Chugh, Brige P.; Quirk, Sarah; Conroy, Leigh; Smith, Wendy L.

    2014-09-15

    Purpose: Gated radiotherapy is used to reduce internal motion margins, escalate target dose, and limit normal tissue dose; however, its temporal accuracy is limited. Beam-on and beam-off time delays can lead to treatment inefficiencies and/or geographic misses; therefore, AAPM Task Group 142 recommends verifying the temporal accuracy of gating systems. Many groups use sinusoidal phantom motion for this, under the tacit assumption that use of sinusoidal motion for determining time delays produces negligible error. The authors test this assumption by measuring gating time delays for several realistic motion shapes with increasing degrees of irregularity. Methods: Time delays were measured on a linear accelerator with a real-time position management system (Varian TrueBeam with RPM system version 1.7.5) for seven motion shapes: regular sinusoidal; regular realistic-shape; large (40%) and small (10%) variations in amplitude; large (40%) variations in period; small (10%) variations in both amplitude and period; and baseline drift (30%). Film streaks of radiation exposure were generated for each motion shape using a programmable motion phantom. Beam-on and beam-off time delays were determined from the difference between the expected and observed streak length. Results: For the system investigated, all sine, regular realistic-shape, and slightly irregular amplitude variation motions had beam-off and beam-on time delays within the AAPM recommended limit of less than 100 ms. In phase-based gating, even small variations in period resulted in some time delays greater than 100 ms. Considerable time delays over 1 s were observed with highly irregular motion. Conclusions: Sinusoidal motion shapes can be considered a reasonable approximation to the more complex and slightly irregular shapes of realistic motion. When using phase-based gating with predictive filters even small variations in period can result in time delays over 100 ms. Clinical use of these systems for patients

  14. Indoor air quality. [Health hazards due to energy conservation measures

    SciTech Connect

    Hollowell, C.D.

    1981-06-01

    Rising energy prices, among other factors, have generated an incentive to reduce ventilation rates and thereby reduce the cost of heating and cooling buildings. Reduced ventilation in buildings may significantly increase exposure to indoor air pollution and perhaps have adverse effects on occupant health and comfort. Preliminary findings suggest that reduced ventilation may adversely affect indoor air quality unless appropriate control strategies are undertaken. The strategies used to control indoor air pollution depend on the specific pollutant or class of pollutants encountered, and differ somewhat depending on whether the application is to an existing building or a new building under design and construction. Whenever possible, the first course of action is prevention or reduction of pollutant emissions at the source. In most buildings, control measures involve a combination of prevention, removal, and suppression. Common sources of indoor air pollution in buildings, the specific pollutants emitted by each source, the potential health effects, and possible control techniques are discussed.

  15. Introduction of New Motion Measurement Equipment into Virtual Walk System

    NASA Astrophysics Data System (ADS)

    Furukawa, Tatsuya; Itoh, Hideaki; Hori, Toshiyuki; Fukumoto, Hisao; Wakuya, Hiroshi; Ohchi, Masashi

    The “Virtual Walk System” has been developed to support rehabilitation therapy in homes. In the system, a user has been able to perform walking-like exercise on a fitness machine called a stepper. In front of the user, a projected image of a vast virtual reality space is generated by 3-dimensional computer graphics (3DCG). The user's movement is measured and the projected image changes just like the user is walking in the virtual space. Viewing the changing image, the user can enjoy the exercise. In this study, we have decomposed the virtual walk system into two modules (the measurement and control module operated by a microcomputer board and the 3DCG module operated by a personal computer) to facilitate rapid development. Then we have introduced two kinds of new equipment, i.e., a bicycle for cycling exercise and a treadmill for walking exercise. We have also developed a treadmill control system by which a user can easily change the walking speed during exercise.

  16. The effect of proficiency level on measurement error of range of motion

    PubMed Central

    Akizuki, Kazunori; Yamaguchi, Kazuto; Morita, Yoshiyuki; Ohashi, Yukari

    2016-01-01

    [Purpose] The aims of this study were to evaluate the type and extent of error in the measurement of range of motion and to evaluate the effect of evaluators’ proficiency level on measurement error. [Subjects and Methods] The participants were 45 university students, in different years of their physical therapy education, and 21 physical therapists, with up to three years of clinical experience in a general hospital. Range of motion of right knee flexion was measured using a universal goniometer. An electrogoniometer attached to the right knee and hidden from the view of the participants was used as the criterion to evaluate error in measurement using the universal goniometer. The type and magnitude of error were evaluated using the Bland-Altman method. [Results] Measurements with the universal goniometer were not influenced by systematic bias. The extent of random error in measurement decreased as the level of proficiency and clinical experience increased. [Conclusion] Measurements of range of motion obtained using a universal goniometer are influenced by random errors, with the extent of error being a factor of proficiency. Therefore, increasing the amount of practice would be an effective strategy for improving the accuracy of range of motion measurements. PMID:27799712

  17. Introductory review on `Flying Triangulation': a motion-robust optical 3D measurement principle

    NASA Astrophysics Data System (ADS)

    Ettl, Svenja

    2015-04-01

    'Flying Triangulation' (FlyTri) is a recently developed principle which allows for a motion-robust optical 3D measurement of rough surfaces. It combines a simple sensor with sophisticated algorithms: a single-shot sensor acquires 2D camera images. From each camera image, a 3D profile is generated. The series of 3D profiles generated are aligned to one another by algorithms, without relying on any external tracking device. It delivers real-time feedback of the measurement process which enables an all-around measurement of objects. The principle has great potential for small-space acquisition environments, such as the measurement of the interior of a car, and motion-sensitive measurement tasks, such as the intraoral measurement of teeth. This article gives an overview of the basic ideas and applications of FlyTri. The main challenges and their solutions are discussed. Measurement examples are also given to demonstrate the potential of the measurement principle.

  18. Drop size distribution and air velocity measurements in air assist swirl atomizer sprays

    NASA Technical Reports Server (NTRS)

    Mao, C.-P.; Oechsle, V.; Chigier, N.

    1987-01-01

    Detailed measurements of mean drop size (SMD) and size distribution parameters have been made using a Fraunhofer diffraction particle sizing instrument in a series of sprays generated by an air assist swirl atomizer. Thirty-six different combinations of fuel and air mass flow rates were examined with liquid flow rates up to 14 lbm/hr and atomizing air flow rates up to 10 lbm/hr. Linear relationships were found between SMD and liquid to air mass flow rate ratios. SMD increased with distance downstream along the center line and also with radial distance from the axis. Increase in obscuration with distance downstream was due to an increase in number density of particles as the result of deceleration of drops and an increase in the exposed path length of the laser beam. Velocity components of the atomizing air flow field measured by a laser anemometer show swirling jet air flow fields with solid body rotation in the core and free vortex flow in the outer regions.

  19. Long-Term Mean Vertical Motion over the Tropical Pacific: Wind-Profiling Doppler Radar Measurements

    NASA Astrophysics Data System (ADS)

    Gage, K. S.; McAfee, J. R.; Carter, D. A.; Ecklund, W. L.; Riddle, A. C.; Reid, G. C.; Balsley, B. B.

    1991-12-01

    Measurement from Christmas Island (2^circN, 157^circW) of long-term mean vertical motions in the tropical atmosphere using very-high-frequency wind-profiling Doppler radar show that there is a transition from downward motion in the free troposphere to upward motion in the upper troposphere and lower stratosphere. The observations in the free troposphere are consistent with a balance between adiabatic and diabatic heating and cooling rates in a clear atmosphere. Comparison of the results at Christmas Island during El Nino and non-El Nino conditions with earlier results obtained for stratiform rain conditions over Pohnpei, Federated States of Micronesia, show that cirrus clouds in the vicinity of the tropopause likely play an important role in determining the sense and magnitude of vertical motions in this region. These results have implications for the exchange of mass between the troposphere and stratosphere over the tropics.

  20. Using an injection signal to reduce motion artifacts in capacitive ECG measurements.

    PubMed

    Serteyn, Aline; Vullings, Rik; Meftah, Mohammed; Bergmans, Jan

    2013-01-01

    Capacitive electrodes are a promising alternative to the conventional adhesive ECG electrodes. They provide more comfort to the patient when integrated in everyday objects (e.g. beds or seats) for long-term monitoring. However, the application of such electrodes is limited by their high sensitivity to motion artifacts. Artifacts caused by variation of the coupling capacitance are studied here. An injection signal is proposed to track these variations in real-time. An adaptive filter then estimates the motion artifact and cancels it from the recorded ECG. The amplitude of the motion artifact is reduced in average by 29 dB in simulation and by 20 dB in a lab environment. Our method has the advantages that it is able to reduce motion artifacts occurring in the frequency band of the ECG and that it does not require knowledge about the measurement system.

  1. Long-Term Mean Vertical Motion over the Tropical Pacific: Wind-Profiling Doppler Radar Measurements.

    PubMed

    Gage, K S; McAfee, J R; Carter, D A; Ecklund, W L; Riddle, A C; Reid, G C; Balsley, B B

    1991-12-20

    Measurement from Christmas Island (2 degrees N, 157 degrees W) of long-term mean vertical motions in the tropical atmosphere using very-high-frequency wind-profiling Doppler radar show that there is a transition from downward motion in the free troposphere to upward motion in the upper troposphere and lower stratosphere. The observations in the free troposphere are consistent with a balance between adiabatic and diabatic heating and cooling rates in a clear atmosphere. Comparison of the results at Christmas Island during El Niño and non-El Niño conditions with earlier results obtained for stratiform rain conditions over Pohnpei, Federated States of Micronesia, show that cirrus clouds in the vicinity of the tropopause likely play an important role in determining the sense and magnitude of vertical motions in this region. These results have implications for the exchange of mass between the troposphere and stratosphere over the tropics.

  2. Wing motion measurement and aerodynamics of hovering true hoverflies.

    PubMed

    Mou, Xiao Lei; Liu, Yan Peng; Sun, Mao

    2011-09-01

    Most hovering insects flap their wings in a horizontal plane (body having a large angle from the horizontal), called `normal hovering'. But some of the best hoverers, e.g. true hoverflies, hover with an inclined stroke plane (body being approximately horizontal). In the present paper, wing and body kinematics of four freely hovering true hoverflies were measured using three-dimensional high-speed video. The measured wing kinematics was used in a Navier-Stokes solver to compute the aerodynamic forces of the insects. The stroke amplitude of the hoverflies was relatively small, ranging from 65 to 85 deg, compared with that of normal hovering. The angle of attack in the downstroke (∼50 deg) was much larger that in the upstroke (∼20 deg), unlike normal-hovering insects, whose downstroke and upstroke angles of attack are not very different. The major part of the weight-supporting force (approximately 86%) was produced in the downstroke and it was contributed by both the lift and the drag of the wing, unlike the normal-hovering case in which the weight-supporting force is approximately equally contributed by the two half-strokes and the lift principle is mainly used to produce the force. The mass-specific power was 38.59-46.3 and 27.5-35.4 W kg(-1) in the cases of 0 and 100% elastic energy storage, respectively. Comparisons with previously published results of a normal-hovering true hoverfly and with results obtained by artificially making the insects' stroke planes horizontal show that for the true hoverflies, the power requirement for inclined stroke-plane hover is only a little (<10%) larger than that of normal hovering. PMID:21832126

  3. Wing motion measurement and aerodynamics of hovering true hoverflies.

    PubMed

    Mou, Xiao Lei; Liu, Yan Peng; Sun, Mao

    2011-09-01

    Most hovering insects flap their wings in a horizontal plane (body having a large angle from the horizontal), called `normal hovering'. But some of the best hoverers, e.g. true hoverflies, hover with an inclined stroke plane (body being approximately horizontal). In the present paper, wing and body kinematics of four freely hovering true hoverflies were measured using three-dimensional high-speed video. The measured wing kinematics was used in a Navier-Stokes solver to compute the aerodynamic forces of the insects. The stroke amplitude of the hoverflies was relatively small, ranging from 65 to 85 deg, compared with that of normal hovering. The angle of attack in the downstroke (∼50 deg) was much larger that in the upstroke (∼20 deg), unlike normal-hovering insects, whose downstroke and upstroke angles of attack are not very different. The major part of the weight-supporting force (approximately 86%) was produced in the downstroke and it was contributed by both the lift and the drag of the wing, unlike the normal-hovering case in which the weight-supporting force is approximately equally contributed by the two half-strokes and the lift principle is mainly used to produce the force. The mass-specific power was 38.59-46.3 and 27.5-35.4 W kg(-1) in the cases of 0 and 100% elastic energy storage, respectively. Comparisons with previously published results of a normal-hovering true hoverfly and with results obtained by artificially making the insects' stroke planes horizontal show that for the true hoverflies, the power requirement for inclined stroke-plane hover is only a little (<10%) larger than that of normal hovering.

  4. Analysis of tissue changes, measurement system effects, and motion artifacts in echo decorrelation imaging.

    PubMed

    Hooi, Fong Ming; Nagle, Anna; Subramanian, Swetha; Douglas Mast, T

    2015-02-01

    Echo decorrelation imaging, a method for mapping ablation-induced ultrasound echo changes, is analyzed. Local echo decorrelation is shown to approximate the decoherence spectrum of tissue reflectivity. Effects of the ultrasound measurement system, echo signal windowing, electronic noise, and tissue motion on echo decorrelation images are determined theoretically, leading to a method for reduction of motion and noise artifacts. Theoretical analysis is validated by simulations and experiments. Simulated decoherence of the scattering medium was recovered with root-mean-square error less than 10% with accuracy dependent on the correlation window size. Motion-induced decorrelation measured in an ex vivo pubovisceral muscle model showed similar trends to theoretical motion-induced decorrelation for a 2.1 MHz curvilinear array with decorrelation approaching unity for 3-4 mm elevational displacement or 1-1.6 mm range displacement. For in vivo imaging of porcine liver by a 7 MHz linear array, theoretical decorrelation computed using image-based motion estimates correlated significantly with measured decorrelation (r = 0.931, N = 10). Echo decorrelation artifacts incurred during in vivo radiofrequency ablation in the same porcine liver were effectively compensated based on the theoretical echo decorrelation model and measured pre-treatment decorrelation. These results demonstrate the potential of echo decorrelation imaging for quantification of heat-induced changes to the scattering tissue medium during thermal ablation.

  5. Analysis of tissue changes, measurement system effects, and motion artifacts in echo decorrelation imaging

    PubMed Central

    Hooi, Fong Ming; Nagle, Anna; Subramanian, Swetha; Douglas Mast, T.

    2015-01-01

    Echo decorrelation imaging, a method for mapping ablation-induced ultrasound echo changes, is analyzed. Local echo decorrelation is shown to approximate the decoherence spectrum of tissue reflectivity. Effects of the ultrasound measurement system, echo signal windowing, electronic noise, and tissue motion on echo decorrelation images are determined theoretically, leading to a method for reduction of motion and noise artifacts. Theoretical analysis is validated by simulations and experiments. Simulated decoherence of the scattering medium was recovered with root-mean-square error less than 10% with accuracy dependent on the correlation window size. Motion-induced decorrelation measured in an ex vivo pubovisceral muscle model showed similar trends to theoretical motion-induced decorrelation for a 2.1 MHz curvilinear array with decorrelation approaching unity for 3–4 mm elevational displacement or 1–1.6 mm range displacement. For in vivo imaging of porcine liver by a 7 MHz linear array, theoretical decorrelation computed using image-based motion estimates correlated significantly with measured decorrelation (r = 0.931, N = 10). Echo decorrelation artifacts incurred during in vivo radiofrequency ablation in the same porcine liver were effectively compensated based on the theoretical echo decorrelation model and measured pre-treatment decorrelation. These results demonstrate the potential of echo decorrelation imaging for quantification of heat-induced changes to the scattering tissue medium during thermal ablation. PMID:25697993

  6. Task Specific Frequencies of Neck Motion Measured in Healthy Young Adults over a 5 Day Period

    PubMed Central

    Cobian, Daniel G.; Sterling, Andrew C.; Anderson, Paul A.; Heiderscheit, Bryan C.

    2010-01-01

    Study Design Observational cohort design. Objective To quantify the frequencies and magnitudes of neck motion during daily activities in healthy subjects. Summary of Background Data Previous studies have measured the maximum excursions during re-created ADLs in lab settings, but there is a lack of information available on frequencies and excursions of neck motion with ADLs in non-artificial settings. Methods Ten healthy young adults were fitted with a portable motion measurement device that recorded movement about each primary axis. Participants were instructed to wear the unit continuously over a 5-day period and record their daily activities with corresponding times. After the collection period, subjects' activity logs were analyzed and data were partitioned into five categories which provided the most primary representation of ADLs: athletics, work, travel, sleep, and miscellaneous. Each category was further divided into increasingly specific activities (e.g. running and walking). Frequency of motions within 5° increments was determined and an hourly rate was calculated for each activity. Median motion about each axis for each activity was also determined. Results The total number of movements per hour for all axes, regardless of amplitude, was highest during athletic activity and lowest during sleeping. The majority of movements (92% of athletic activity, 90% of work) required less than 25° of lateral bending, while greater range of movement requirements were observed for flexion-extension and axial rotation. The median range of motion along all axes was highest for athletic activity and lowest for sleeping. Conclusions The results of this study provide a baseline of the frequency and magnitude of neck motion during normal ADLs for the specified population. These findings can assist physicians and physical therapists in determining the extent of disability and identifying activities that will likely be problematic for patients with limited cervical motion

  7. Wavefront measurements of a laser-induced breakdown spark in still air.

    PubMed

    Rennie, R Mark; Goorskey, David; Whiteley, Matthew R; Jumper, Eric J

    2012-05-01

    Experimental measurements of the wavefronts of the light from a laser-induced breakdown (LIB) spark in non-moving air are presented and compared to spark dimensional data acquired from photographic measurements of the spark. The data show that the variation in the spark emitted wavefront between ignitions can be directly related to the motion of the spark volumetric centroid. The dominant modal components of the emitted wavefront variations are presented, as well as quantitative results for the magnitude of the wavefront variations. The results are relevant to the use of LIB as a light source for the measurement of optical aberrations such as those caused by compressible (i.e., "aero-optic") flows around an aircraft in flight, and data are shown indicating that LIB could be successfully used to measure the aberrating effect of compressible shear layers and boundary layers at typical cruise Mach numbers. PMID:22614405

  8. FMPS measurement of nanoparticle pollutant in office air

    NASA Astrophysics Data System (ADS)

    Yin, Zhaoqin; Lin, Jianzhong; Yu, Mingzhou

    2010-08-01

    Fast Mobility Particle Sizer (FMPS) is an electrical mobility instrument used to measure the nanoparticle number concentration and size distribution in an office environment. Actual measurements indicate the distributions of ultrafine particle number and size in office air are inhomogeneous in space. The nonaparticle size is bimodal and log-normally distribution in an office environment when only people activities are considered. The traffic pollutant in the outdoor including the automobile tail gas and the dust will change the particles size distribution and enhance the particle number concentration those of indoor air. It can also be seen from the results that the laser printer releases a large number of nanoparticles, especially around 80nm in diameter in the printing process. The laser printer may be the mainly ultrafine particle source in the office air.

  9. Measurement of air toxics using extractive FTIR spectroscopy

    SciTech Connect

    Lacoss, J.P.; Ogle, L.D.; Shareef, G.S.

    1995-12-31

    In response to the 1990 Clean Air Act Amendments, the Gas Research Institute (GRI) is investigating air toxics emissions from natural gas industry sources. Included in this effort are measurements from internal combustion engines, one of the source categories targeted by U.S. Environmental Protection Agency (EPA) for development of maximum achievable control technology (MACT) based regulations by the year 2000. Formaldehyde and other aldehydes are the air toxics potentially present in engine exhaust. Since there are no EPA approved methods available for quantifying aldehydes in engine exhaust, GRI initiated a field test to validate an extractive Fourier transform infrared spectroscopy (FTIR) based method according to U.S. EPA Method 301 {open_quotes}Field Validation of Pollutant Measurement Methods for Various Media{close_quotes}. The extended paper presents the results of this validation testing for formaldehyde, acetaldehyde, and acrolein conducted to support this validation testing.

  10. Monte Carlo study of TLD measurements in air cavities.

    PubMed

    Haraldsson, Pia; Knöös, Tommy; Nyström, Håkan; Engström, Per

    2003-09-21

    Thermoluminescent dosimeters (TLDs) are used for verification of the delivered dose during IMRT treatment of head and neck carcinomas. The TLDs are put into a plastic tube, which is placed in the nasal cavities through the treated volume. In this study, the dose distribution to a phantom having a cylindrical air cavity containing a tube was calculated by Monte Carlo methods and the results were compared with data from a treatment planning system (TPS) to evaluate the accuracy of the TLD measurements. The phantom was defined in the DOSXYZnrc Monte Carlo code and calculations were performed with 6 MV fields, with the TLD tube placed at different positions within the cylindrical air cavity. A similar phantom was defined in the pencil beam based TPS. Differences between the Monte Carlo and the TPS calculations of the absorbed dose to the TLD tube were found to be small for an open symmetrical field. For a half-beam field through the air cavity, there was a larger discrepancy. Furthermore, dose profiles through the cylindrical air cavity show, as expected, that the treatment planning system overestimates the absorbed dose in the air cavity. This study shows that when using an open symmetrical field, Monte Carlo calculations of absorbed doses to a TLD tube in a cylindrical air cavity give results comparable to a pencil beam based treatment planning system.

  11. Disruptive Innovation in Air Measurement Technology: Reality or Hype?

    EPA Science Inventory

    This presentation is a big picture overview on the changing state of air measurement technology in the world, with a focus on the introduction of low-cost sensors into the market place. The presentation discusses how these new technologies may be a case study in disruptive innov...

  12. Measuring radon concentration in air using a diffusion cloud chamber

    NASA Astrophysics Data System (ADS)

    Cases, R.; Ros, E.; Zúñiga, J.

    2011-09-01

    Radon concentration in air is a major concern in lung cancer studies. A traditional technique used to measure radon abundance is the charcoal canister method. We propose a novel technique using a diffusion cloud chamber. This technique is simpler and can easily be used for physics demonstrations for high school and university students.

  13. METHOD FOR MEASURING AIR-IMMISCIBLE LIQUID PARTITION COEFFICIENTS

    EPA Science Inventory

    The principal objective of this work was to measure nonaqueous phase liquid-air partition coefficients for various gas tracer compounds. Known amounts of trichloroethene (TCE) and tracer, as neat compounds, were introduced into glass vials and allowed to equilibrate. The TCE and ...

  14. Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

    SciTech Connect

    Sherman, Max; Sherman, Max H.; Walker, Iain S.

    2008-05-01

    The purpose of ventilation is dilute or remove indoor contaminants that an occupant is exposed to. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. Most US homes have central HVAC systems, which tend to mix the air thus the indoor conditions between zones. Different types of ventilation systems will provide different amounts of exposure depending on the effectiveness of their air distribution systems and the location of sources and occupants. This paper will report on field measurements using a unique multi-tracer measurement system that has the capacity to measure not only the flow of outdoor air to each zone, but zone-to-zone transport. The paper will derive seven different metrics for the evaluation of air distribution. Measured data from two homes with different levels of natural infiltration will be used to evaluate these metrics for three different ASHRAE Standard 62.2 compliant ventilation systems. Such information can be used to determine the effectiveness of different systems so that appropriate adjustments can be made in residential ventilation standards such as ASHRAE Standard 62.2.

  15. Temperature Measurement in Microhollow Cathode Discharges in Atmospheric Air

    NASA Astrophysics Data System (ADS)

    Block, Rolf; Toedter, Olaf; Schoenbach, Karl H.

    1998-10-01

    By reducing the diameter of the cathode opening in hollow cathode discharge geometry to values on the order of one hundred micrometers we were able to operate the discharges in a direct current mode at atmospheric pressure in air. The possibility to operate microhollow cathode discharges (MHCD) in parallel [1] in atmospheric air opens a wide range of applications. At atmospheric pressures, the electric power of a single discharge was measured as 8W. The power density in the microhollow exceeds 1MW/cm^3. This leads to strong thermal loading of the electrodes. In order to study the thermal properties of the discharge we have used a method based on emission spectroscopy. The rotational structure of the emitted lines corresponding to the second positive system of nitrogen contains information on the neutral gas temperature. Taking the apparatus profile into account the temperature of the rotational excited molecules can be estimated by a comparison of simulated and measured data. Measurements on MHCD up to atmospheric pressure show an increase in the neutral gas temperature to values exceeding 1000K. In addition to the gas temperature the electrode temperatures were measured and the thermodynamic behavior of the electrode configuration was calculated. [1] W. Shi, K.H. Schoenbach Parallel Operation of Microhollow Cathode Discharges, ICOPS98, Raleigh, NC, USA, 1998 This work was funded by the Air Force Office of Scientific Research (AFOSR) in cooperation with the DDR&E Air Plasma Ramparts MURI program, and by the Department of Energy, Advanced Energy Division.

  16. Global Ammonia Concentrations Seen by the 13-years AIRS Measurements

    NASA Astrophysics Data System (ADS)

    Warner, Juying; Wei, Zigang; Larrabee Strow, L.; Dickerson, Russell; Nowak, John; Wang, Yuxuan

    2016-04-01

    Ammonia is an integral part of the nitrogen cycle and is projected to be the largest single contributor to each of acidification, eutrophication and secondary particulate matter in Europe by 2020 (Sutton et al., 2008). The impacts of NH3 also include: aerosol production affecting global radiative forcing, increases in emissions of the greenhouse gases nitrous oxide (N2O) and methane (CH4), and modification of the transport and deposition patterns of SO2 and NOx. Therefore, monitoring NH3 global distribution of sources is vitally important to human health with respect to both air and water quality and climate change. We have developed new daily and global ammonia (NH3) products from AIRS hyperspectral measurements. These products add value to AIRS's existing products that have made significant contributions to weather forecasts, climate studies, and air quality monitoring. With longer than 13 years of data records, these measurements have been used not only for daily monitoring purposes but also for inter-annual variability and short-term trend studies. We will discuss the global NH3 emission sources from biogenic and anthropogenic activities over many emission regions captured by AIRS. We will focus their variability in the last 13 years.

  17. Dynamics and control of motion on the ground and in the air with application to biped robots

    NASA Astrophysics Data System (ADS)

    Hemami, H.; Zheng, Y.-F.

    The dynamics of a multi-linkage model of natural or man-made systems with arbitrary holonomic and non-holonomic constraints at the joints are formulated. The formulation is equally applicable to movements on the ground or in the air. Nonlinear control strategies for postural balance and rhythmic motion are presented. A predictive algorithm to compensate for computation or transmission delay is proposed. Digital computer simulations are presented to demonstrate the effectiveness of the control strategy for a five-link three-dimensional biped.

  18. CARS Temperature and Species Measurements For Air Vehicle Propulsion Systems

    NASA Technical Reports Server (NTRS)

    Danehy, Paul M.; Gord, James R.; Grisch, Frederic; Klimenko, Dmitry; Clauss, Walter

    2005-01-01

    The coherent anti-Stokes Raman spectroscopy (CARS) method has recently been used in the United States and Europe to probe several different types of propulsion systems for air vehicles. At NASA Langley Research Center in the United States, CARS has been used to simultaneously measure temperature and the mole fractions of N2, O2 and H2 in a supersonic combustor, representative of a scramjet engine. At Wright- Patterson Air Force Base in the United States, CARS has been used to simultaneously measure temperature and mole fractions of N2, O2 and CO2, in the exhaust stream of a liquid-fueled, gas-turbine combustor. At ONERA in France and the DLR in Germany researchers have used CARS to measure temperature and species concentrations in cryogenic LOX-H2 rocket combustion chambers. The primary aim of these measurements has been to provide detailed flowfield information for computational fluid dynamics (CFD) code validation.

  19. Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images

    NASA Astrophysics Data System (ADS)

    Marchant, T. E.; Amer, A. M.; Moore, C. J.

    2008-02-01

    A method is presented for extraction of intra and inter fraction motion of seeds/markers within the patient from cone beam CT (CBCT) projection images. The position of the marker is determined on each projection image and fitted to a function describing the projection of a fixed point onto the imaging panel at different gantry angles. The fitted parameters provide the mean marker position with respect to the isocentre. Differences between the theoretical function and the actual projected marker positions are used to estimate the range of intra fraction motion and the principal motion axis in the transverse plane. The method was validated using CBCT projection images of a static marker at known locations and of a marker moving with known amplitude. The mean difference between actual and measured motion range was less than 1 mm in all directions, although errors of up to 5 mm were observed when large amplitude motion was present in an orthogonal direction. In these cases it was possible to calculate the range of motion magnitudes consistent with the observed marker trajectory. The method was shown to be feasible using clinical CBCT projections of a pancreas cancer patient.

  20. Laser vibrometer analysis of sensor loading effects in underwater measurements of compliant surface motion

    SciTech Connect

    Caspall, J.J.; Gray, M.D.; Caille, G.W.; Jarzynski, J.; Rogers, P.H.; McCall, G.S. II

    1996-04-01

    The application of contact motion sensors, such as accelerometers, in the measurement of the vibration of compliant surfaces underwater may lead to errors in the evaluation of certain types of surface motion. An underwater scanning laser Doppler vibrometer (USLDV) was used to measure the scattered velocity field due to a mock sensor (rigid, neutrally buoyant cylindrical body) on a compliant surface (the outer surface of a thin cylindrical shell coated with a layer of soft rubber). Axially propagating waves were launched in the shell by a ring of 10 uniformly distributed shakers located near one end of the shell and driven with a short pulse. The outer surface of the coating was scanned over a short line segment in the axial direction with and without the mock sensor attached. The extracted scattered field, consisted of high wavenumber fluid-solid interface waves accompanied by rotational motion of the mock sensor. [Work supported by ONR] {copyright} {ital 1996 American Institute of Physics.}

  1. Measurement of forces due to liquid motion in a propellant tank

    NASA Technical Reports Server (NTRS)

    Tegart, J. R.; Berry, R. L.; Demchak, L. J.; Craig, M. K.

    1981-01-01

    This paper presents the results of a study to develop an analytical model capable of predicting the forces acting on a tank caused by large-amplitude propellant motion. This effort contributed to an analysis of the influence of propellant dynamics on separation of the External Tank from the space shuttle orbiter. This paper is concerned with an experimental investigation that aided in development and verification of the analytical model. A scaling approach was developed that allowed the liquid motion to be simulated in subscale tanks. Liquid reorientation forces were measured using two test systems. One operated in the low-gravity environment produced in a drop tower and the second operated aboard the KC-135 'zero-g' test aircraft. The manner of liquid motion, influence of various factors, and the measured forces are discussed.

  2. Definition of air quality measurements for monitoring space shuttle launches

    NASA Technical Reports Server (NTRS)

    Thorpe, R. D.

    1978-01-01

    A description of a recommended air quality monitoring network to characterize the impact on ambient air quality in the Kennedy Space Center (KSC) (area) of space shuttle launch operations is given. Analysis of ground cloud processes and prevalent meteorological conditions indicates that transient HCl depositions can be a cause for concern. The system designed to monitor HCl employs an extensive network of inexpensive detectors combined with a central analysis device. An acid rain network is also recommended. A quantitative measure of projected minimal long-term impact involves the limited monitoring of NOx and particulates. All recommended monitoring is confined ti KSC property.

  3. Measurement of wind profiles by motion-stabilised ship-borne Doppler lidar

    NASA Astrophysics Data System (ADS)

    Achtert, P.; Brooks, I. M.; Brooks, B. J.; Moat, B. I.; Prytherch, J.; Persson, P. O. G.; Tjernström, M.

    2015-09-01

    Three months of Doppler lidar wind measurements were obtained during the Arctic Cloud Summer Experiment on the icebreaker Oden during the summer of 2014. Such ship-borne measurements require active stabilisation to remove the effects of ship motion. We demonstrate that the combination of a commercial Doppler lidar with a custom-made motion-stabilisation platform enables the retrieval of wind profiles in the Arctic boundary layer during both cruising and ice-breaking with statistical uncertainties comparable to land-based measurements. This holds particularly within the planetary boundary layer even though the overall aerosol load was very low. Motion stabilisation was successful for high wind speeds in open water and the resulting wave conditions. It allows for the retrieval of winds with a random error below 0.2 m s-1, comparable to the measurement error of standard radiosondes. The combination of a motion-stabilised platform with a low-maintenance autonomous Doppler lidar has the potential to enable continuous long-term high-resolution ship-based wind profile measurements over the oceans.

  4. Measurement of wind profiles by motion-stabilised ship-borne Doppler lidar

    NASA Astrophysics Data System (ADS)

    Achtert, P.; Brooks, I. M.; Brooks, B. J.; Moat, B. I.; Prytherch, J.; Persson, P. O. G.; Tjernström, M.

    2015-11-01

    Three months of Doppler lidar wind measurements were obtained during the Arctic Cloud Summer Experiment on the icebreaker Oden during the summer of 2014. Such ship-borne Doppler measurements require active stabilisation to remove the effects of ship motion. We demonstrate that the combination of a commercial Doppler lidar with a custom-made motion-stabilisation platform enables the retrieval of wind profiles in the Arctic atmospheric boundary layer during both cruising and ice-breaking with statistical uncertainties comparable to land-based measurements. This held true particularly within the atmospheric boundary layer even though the overall aerosol load was very low. Motion stabilisation was successful for high wind speeds in open water and the resulting wave conditions. It allows for the retrieval of vertical winds with a random error below 0.2 m s-1. The comparison of lidar-measured wind and radio soundings gives a mean bias of 0.3 m s-1 (2°) and a mean standard deviation of 1.1 m s-1 (12°) for wind speed (wind direction). The agreement for wind direction degrades with height. The combination of a motion-stabilised platform with a low-maintenance autonomous Doppler lidar has the potential to enable continuous long-term high-resolution ship-based wind profile measurements over the oceans.

  5. Assessment of tissue Doppler imaging measurements of arterial wall motion using a tissue mimicking test rig.

    PubMed

    Thrush, Abigail J; Brewin, Mark P; Birch, Malcolm J

    2008-03-01

    The aim of this in vitro study is to assess the accuracy of the tissue Doppler imaging arterial wall motion (TDI AWM) technique in measuring dilation over a range of distances and velocities. A test rig, consisting of two parallel blocks of tissue mimicking material (TMM), has been developed to generate known wall motion. One block remains stationary while the other moves in a cyclical motion. A calibrated laser range finder was used to measure the TMM motion. The TDI AWM measurements were found to underestimate the dilation by 21% +/- 4.7% when using the recommended scanner parameters. The size of the error was found to increase with a decrease in ultrasound output power. Results suggested that errors in the TDI AWM dilation measurements relate to underestimates in the velocity measured by the TDI technique. The error demonstrated in this study indicates a limitation in the value of TDI AWM result obtained in vivo. (E-mail: abigail.thrush@bartsandthelondon.nhs.uk). PMID:17964065

  6. Real-time weigh-in-motion measurement using fiber Bragg grating sensors

    NASA Astrophysics Data System (ADS)

    Huang, Ying; Palek, Leonard; Strommen, Robert; Worel, Ben; Chen, Genda

    2014-03-01

    Overloading truck loads have long been one of the key reasons for accelerating road damage, especially in rural regions where the design loads are expected to be small and in the cold regions where the wet-and-dry cycle places a significant role. To control the designed traffic loads and further guide the road design in future, periodical weight stations have been implemented for double check of the truck loads. The weight stations give chances for missing measurement of overloaded vehicles, slow down the traffic, and require additional labors. Infrastructure weight-in-motion sensors, on the other hand, keep consistent traffic flow and monitor all types of vehicles on roads. However, traditional electrical weight-in-motion sensors showed high electromagnetic interference (EMI), high dependence on environmental conditions such as moisture, and relatively short life cycle, which are unreliable for long-term weigh-inmotion measurements. Fiber Bragg grating (FBG) sensors, with unique advantages of compactness, immune to EMI and moisture, capability of quasi-distributed sensing, and long life cycle, will be a perfect candidate for long-term weigh-in-motion measurements. However, the FBG sensors also surfer from their frangible nature of glass materials for a good survive rate during sensor installation. In this study, the FBG based weight-in-motion sensors were packaged by fiber reinforced polymer (FRP) materials and further validated at MnROAD facility, Minnesota DOT (MnDOT). The design and layout of the FRP-FBG weight-in-motion sensors, their field test setup, data acquisition, and data analysis will be presented. Upon validation, the FRP-FBG sensors can be applied weigh-in-motion measurement to assistant road managements.

  7. Measurement of the Three-Dimensional Vibration Motion of the Ossicular Chain in the Living Gerbil

    NASA Astrophysics Data System (ADS)

    Decraemer, Willem F.; de La Rochefoucauld, Ombeline; Olson, Elizabeth S.

    2011-11-01

    In previous studies 3D motion of the middle-ear ossicles in cat and human temporal bone were explored but models for hearing research has shifted in the last decades to smaller mammals and gerbil in particular has become a hearing model of first choice. In the present study we have measured with an optical interferometer the 3D motion of the malleus and incus in anesthetized gerbil for sound of moderate intensity (90 dB SPL) in a broad frequency range. To access the malleus and incus the pars flaccida was completely removed exposing the neck and head of the malleus and the incus from the malleus-incus joint to the long process of the incus and the plate of the lenticular process. In a previous study an approach through a hole in the bullar wall was used to study the stapes motion so that we now have a complete picture of the middle ear motion. In both approaches vibration measurements were done at 6 to 7 points per ossicle while the angle of observation was varied over approximately 30 degrees to enable calculation of the 3D velocity components. Knowledge of middle ear motion is of great importance in understanding how the middle ear transforms the acoustical input from the ear canal to the cochlea.

  8. Measuring tongue motion from tagged cine-MRI using harmonic phase (HARP) processing.

    PubMed

    Parthasarathy, Vijay; Prince, Jerry L; Stone, Maureen; Murano, Emi Z; Nessaiver, Moriel

    2007-01-01

    A cine series of tagged magnetic resonance (MR) images of the tongue is used to measure tongue motion and its internal deformation during speech. Tagged images are collected in three slice orientations (sagittal, coronal, and axial) during repetitions of the utterance "disouk" (/disuk/). A new technique called harmonic phase MRI (HARP-MRI) is used to process the tagged MR images to measure the internal deformation of the tongue. The measurements include displacement and velocity of tissue points, principal strains, and strain in the line-of-action of specific muscles. These measurements are not restricted to tag intersections, but can be calculated at every pixel in the image. The different motion measurements complement each other in understanding the tongue kinematics and in hypothesizing the internal muscle activity of the tongue.

  9. Influence of temperature changes on ambient air NOx chemiluminescence measurements.

    PubMed

    Miñarro, Marta Doval; Ferradás, Enrique González; Martínez, Francisco J Marzal

    2012-09-01

    Users of automatic air pollution monitors are largely unaware of how certain parameters, like temperature, can affect readings. The present work examines the influence of temperature changes on chemiluminescence NO(x) measurements made with a Thermo Scientific 42i analyzer, a model widely used in air monitoring networks and air pollution studies. These changes are grouped into two categories according to European Standard EN 14211: (1) changes in the air surrounding the analyzers and (2) changes in the sampled air. First, the sensitivity tests described in Standard EN 14211 were performed to determine whether the analyzer performance was adapted to the requirements of the standard. The analyzer met the performance criteria of both tests; however, some differences were detected in readings with temperature changes even though the temperature compensator was on. Sample temperature changes were studied more deeply as they were the most critical (they cannot be controlled and differences of several tens of degrees can be present in a single day). Significant differences in readings were obtained when changing sample temperature; however, maximum deviations were around 3% for temperature ranges of 15°C. If other possible uncertainty contributions are controlled and temperature variations with respect to the calibration temperature are not higher than 15°C, the effect of temperature changes could be acceptable and no data correction should have to be applied. PMID:21964932

  10. Measurement of six degree-of-freedom ground motion by using eight accelerometers

    NASA Astrophysics Data System (ADS)

    Yang, Zhenyu; Shen, Yi; Liu, Zhiyan

    2005-12-01

    A new integrated measuring system with eight force-balance accelerometers is proposed to obtain a direct measurement of six degree-of freedom (DOF) ground motions, including three rotational and three actual translational acceleration components without gyroscopes. In the proposed measuring system, the relationship between the output from eight force-balance accelerometer and the six DOF motion of the measuring system under an earthquake are described by differential equations. These equations are derived from the positions and directions of the eight force-balance accelerometers in the measuring system. The third-order Runge-Kutta algorithm is used to guarantee the accuracy of the numerical calculation. All the algorithms used to compute the six DOF components of the ground motion are implemented in a real-time in Digital Signal Processor (DSP). The distortion of the measured results caused by position and direction errors of the accelerometers in the measuring system are reduced by multiplying a compensation coefficient C to the output and subtracting static zero drift from the measured results, respectively.

  11. Suggested Courseware for the Non-Calculus Physics Student: Measurement, Vectors, and One-Dimensional Motion.

    ERIC Educational Resources Information Center

    Mahoney, Joyce; And Others

    1988-01-01

    Evaluates 16 commercially available courseware packages covering topics for introductory physics. Discusses the price, sub-topics, program type, interaction, time, calculus required, graphics, and comments of each program. Recommends two packages in measurement and vectors, and one-dimensional motion respectively. (YP)

  12. Wave motion on the surface of the human tympanic membrane: Holographic measurement and modeling analysis

    PubMed Central

    Cheng, Jeffrey Tao; Hamade, Mohamad; Merchant, Saumil N.; Rosowski, John J.; Harrington, Ellery; Furlong, Cosme

    2013-01-01

    Sound-induced motions of the surface of the tympanic membrane (TM) were measured using stroboscopic holography in cadaveric human temporal bones at frequencies between 0.2 and 18 kHz. The results are consistent with the combination of standing-wave-like modal motions and traveling-wave-like motions on the TM surface. The holographic techniques also quantified sound-induced displacements of the umbo of the malleus, as well as volume velocity of the TM. These measurements were combined with sound-pressure measurements near the TM to compute middle-ear input impedance and power reflectance at the TM. The results are generally consistent with other published data. A phenomenological model that behaved qualitatively like the data was used to quantify the relative magnitude and spatial frequencies of the modal and traveling-wave-like displacement components on the TM surface. This model suggests the modal magnitudes are generally larger than those of the putative traveling waves, and the computed wave speeds are much slower than wave speeds predicted by estimates of middle-ear delay. While the data are inconsistent with simple modal displacements of the TM, an alternate model based on the combination of modal motions in a lossy membrane can also explain these measurements without invoking traveling waves. PMID:23363110

  13. 38 CFR 4.71 - Measurement of ankylosis and joint motion.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Measurement of ankylosis and joint motion. 4.71 Section 4.71 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.71...

  14. The development of femtosecond electron diffraction for direct measurements of ultrafast atomic motions

    NASA Astrophysics Data System (ADS)

    Park, Hyuk

    The evolution of material structures is governed by the making and breaking of chemical bonds and the rearrangement of atoms, which occurs on the time scale of an atomic vibrational period, hundreds of femtoseconds. Atomic motion on this time scale ultimately determines the course of phase transitions in solids, the kinetic pathways of chemical reactions, and even the function of biological processes. Direct observation and understanding these ultrafast structural dynamics at the time and length scales of atomic motions represent an important frontier in scientific research and applications. We have developed a femtosecond electron diffraction system (FED) capable of directly measuring the atomic motions in sub-picosecond temporal resolution and sub-milli-angstrom spatial resolution. In the path of the development of FED various technical challenges have been overcome and an unprecedented capability has been achieved. These advancements allow us to study a range of ultrafast structural dynamics directly on the fundamental level of atomic motions for the first time. With FED we measured laser-induced ultrafast structural dynamics in a 20-nm Al film by taking real-time snapshots of transmission electron patterns. The damped single-mode breathing motion of the Al film along the surface normal was recorded as coherent and in-phase oscillations of all the Bragg peak positions. The concurrent lattice heating was measured by tracking the associated Bragg peak intensity attenuation. This acoustic phonon can be well fitted with a classical harmonic oscillator model using a driving force which includes both electronic and lattice contribution. The pressure of the free electrons contributes significantly in driving the coherent acoustic phonons under nonequilibrium conditions when electrons and phonons are not thermalized. In addition, by using a pair of optical excitation pulses and varying their time delay and relative pulse intensities, we demonstrated successful control

  15. Characterization of elastic and inelastic aquifer motion from satellite geodetic measurements

    NASA Astrophysics Data System (ADS)

    Bawden, G. W.

    2005-05-01

    The production of ground water in confined aquifer systems often results in a land- surface motion that is in a gradient between two end-member models--elastic deformation and inelastic deformation--that is directly measurable by satellite-based geodetic techniques. Elastic deformation is manifested by seasonal motion associated with the pumping, but with no permanent deformation; inelastic deformation results from permanent compaction of the fine-grained units and unrecoverable subsidence of the land surface. The combination of InSAR imagery, GPS measurements, and water-levels for Salt Lake City, UT, Chino Basin, CA and the metropolitan Los Angeles-Santa Ana region, CA, are used to characterize the end-member models and a hybrid model to show how aquifers respond to ground-water pumping stresses. In Salt Lake City, ground-water pumping results in a strong seasonal motion of as much as 85 mm that is not associated with any measurable long-term subsidence signal. Conversely the Chino Basin is subsiding at a rate of 34 mm/yr from ground-water pumping, with little seasonal motion. In the Los Angeles-Santa Ana region there is both elastic and inelastic motion, with greater than 60 mm of seasonal motion associated with 20 mm/year of subsidence. The inelastic subsidence began in 1995 and has been associated with a change in ground-water pumping policy. Improved characterization of these aquifer systems, and associated subsidence, may result in more effective approaches to ground-water resource management.

  16. Designed microtremor array based actual measurement and analysis of strong ground motion at Palu city, Indonesia

    SciTech Connect

    Thein, Pyi Soe; Pramumijoyo, Subagyo; Wilopo, Wahyu; Setianto, Agung; Brotopuspito, Kirbani Sri; Kiyono, Junji; Putra, Rusnardi Rahmat

    2015-04-24

    In this study, we investigated the strong ground motion characteristics under Palu City, Indonesia. The shear wave velocity structures evaluated by eight microtremors measurement are the most applicable to determine the thickness of sediments and average shear wave velocity with Vs ≤ 300 m/s. Based on subsurface underground structure models identified, earthquake ground motion was estimated in the future Palu-Koro earthquake by using statistical green’s function method. The seismic microzonation parameters were carried out by considering several significant controlling factors on ground response at January 23, 2005 earthquake.

  17. Development and clinical evaluation of a simple optical method to detect and measure patient external motion.

    PubMed

    Barbés, Benigno; Azcona, Juan Diego; Prieto, Elena; de Foronda, José Manuel; García, Marina; Burguete, Javier

    2015-01-01

    A simple and independent system to detect and measure the position of a number of points in space was devised and implemented. Its application aimed to detect patient motion during radiotherapy treatments, alert of out-of-tolerances motion, and record the trajectories for subsequent studies. The system obtains the 3D position of points in space, through its projections in 2D images recorded by two cameras. It tracks black dots on a white sticker placed on the surface of the moving object. The system was tested with linear displacements of a phantom, circular trajectories of a rotating disk, oscillations of an in-house phantom, and oscillations of a 4D phantom. It was also used to track 461 trajectories of points on the surface of patients during their radiotherapy treatments. Trajectories of several points were reproduced with accuracy better than 0.3 mm in the three spatial directions. The system was able to follow periodic motion with amplitudes lower than 0.5 mm, to follow trajectories of rotating points at speeds up to 11.5 cm/s, and to track accurately the motion of a respiratory phantom. The technique has been used to track the motion of patients during radiotherapy and to analyze that motion. The method is flexible. Its installation and calibration are simple and quick. It is easy to use and can be implemented at a very affordable price. Data collection does not involve any discomfort to the patient and does not delay the treatment, so the system can be used routinely in all treatments. It has an accuracy similar to that of other, more sophisticated, commercially available systems. It is suitable to implement a gating system or any other application requiring motion detection, such as 4D CT, MRI or PET. PMID:26699313

  18. Crustal motion in the Antarctic interior from a decade of Global Positioning System measurements

    NASA Astrophysics Data System (ADS)

    Willis, Michael J.

    A decade of Global Positioning System (GPS) data have been collected at bedrock sites in southern Victoria Land, Antarctica. Measured motions of the crust have been examined to determine if ongoing tectonic deformation occurs within the study area, across the structural boundary between East and West Antarctica. Crustal motions are used to test for activity over the offshore Terror Rift, where young faulting is documented, and to assess locally whether the active Erebus volcano deforms the crust. Bedrock motions caused by large scale ice-mass changes that have occurred in the area since the Last Glacial Maximum are also a major focus of the study. The horizontal GPS motions record Antarctic plate motion of ˜15 mm/yr to the southeast. No deformation is observed over the Transantarctic Mountains Front Zone. Very small amounts of deformation are observed along the Terror Rift, however the recorded direction of motions may be the result of Glacial Isostatic Adjustment (GIA), rather than active tectonics. Recorded motions observed to the south of Ross Island suggest that the Terror Rift continues beneath the Ross Ice Shelf. No volcanic loading signal is observed. Vertical crustal motions exhibit a down-to-the-east tilt over the study area. A suite of earth models, including more than three hundred different mantle viscosity profiles, three different lithospheric thicknesses and three different ice histories, were used to model uplift due to Glacial Isostatic Adjustment driven by ice mass change. None replicate the observed tilt. Two Relative Sea Level curves for the region also could not be replicated by GIA models examined. Comparison of GPS vertical velocities and our GIA models produce well-constrained earth models for the study area, but suggest that current ice history models for the region must be revised to replicate measured crustal motions. We compare the output of our GPS-constrained models with published crustal uplift rates used in modern ice mass balance

  19. Directional-sensitive differential laser Doppler vibrometry for in-plane motion measurement of specular surface

    NASA Astrophysics Data System (ADS)

    Agusanto, Kusuma; Lau, Gih-Keong; Wu, Kun; Liu, Ting; Zhu, Chuangui; Yuan, Ling

    2015-03-01

    A new method for measuring in-plane vibration velocity of glossy and specular surface using differential laser Doppler vibrometer (LDV) is proposed in this work. A standard tangential LDV using similar differential configuration is only able to measure in-plane velocity of objects with rough surface, due to its inherent on-axis optical design that collects backscatter light along its optical axis. The proposed method adopts an off-axis detection scheme, in which the photodetector is decoupled from LDV, and placed along the dominant direction of the scattered light. For optimal placement, the bidirectional reflectance distribution function (BRDF) of the sample must be considered ideally, but in our measurement tests, the off-axis detection along the direction of specular reflection is sufficient to obtain good measurement results. Another advantage with this setup is that it also works with the objects with rough surface. Experimental works using the standard tangential LDV and a prototype of this method were conducted to measure the in-plane motion of four different samples representing rough, glossy and mirror-like surface. An electrodynamic shaker was used to provide the in-plane motion of the samples at three different frequencies. A single point axial vibrometer was used to validate the in-plane velocity of the measurement from both in-plane LDVs. Some preliminary results showed that the in-plane motion of the object with glossy and specular surface can be measured using the proposed method.

  20. Role of the area postrema in three putative measures of motion sickness in the rat

    NASA Technical Reports Server (NTRS)

    Sutton, Richard L.; Fox, Robert A.; Daunton, Nancy G.

    1991-01-01

    After thermal cauterization of the area postrema in rats, the absence of conditioned taste aversion of sucrose paired with lithium chloride (0.15M, 3.3 ml/kg) was used as a pharmacologic/behavioral index of area postrema damage. In a subsequent experiment the effects of area postrema lesions on three measures proposed as species-relevant measures of motion sickness were studied, using off-vertical rotation at 150 deg/s for either 30 or 90 min. Lesions of area postrema did not alter postrotational suppression of drinking or amount of defecation during motion. The initial acquisition of conditioned taste aversion to a novel cider vinegar solution paired with motion was not affected by lesioning of the area postrema, but these taste aversions extinguished more slowly in lesioned rats than in sham-operates or intact controls. Results are discussed in terms of proposed humoral factors which may induce motion sickness and in light of recent data on the role of the area postrema in similar measures in species possessing the complete emetic reflex.

  1. Application of a novel spinal posture and motion measurement system in active and static sitting.

    PubMed

    Pries, Esther; Dreischarf, Marcel; Bashkuev, Maxim; Schmidt, Hendrik

    2015-01-01

    The quantification of work-related musculoskeletal risk factors is of great importance; however, only a few tools allow objective, unrestricted measurements of spinal posture and motion in workplaces. This study was performed to evaluate the applicability of the Epionics system in a sedentary workplace. The system is mobile and wireless and assesses lumbar lordosis, pelvic orientation and spinal motion, without restricting subjects in their movements. In total, 10 males were monitored while sitting for 2 h on static and dynamic office chairs and on an exercise ball, to evaluate the effect of dynamic sitting. The volunteers were able to perform their work unhampered. No differences among the tested furniture could be detected with respect to either the lordosis or the number of spinal movements after habituation to the furniture; however, differences in pelvic orientation were statistically significant. The results of the present study indicate that Epionics may be useful for the quantitative assessment of work-related risk factors. Practitioner Summary: Only a few tools allow objective, unrestricted measurements of spinal posture and motion in the workplace. Epionics SPINE measures lumbar lordosis, pelvic orientation and spinal motion under nearly unrestricted conditions and can be used to quantify work-related musculoskeletal risk factors. We demonstrated the use of this tool in the workplace-analysis. PMID:25712870

  2. Nanomechanical motion measured with an imprecision below the standard quantum limit

    NASA Astrophysics Data System (ADS)

    Donner, Tobias

    2010-03-01

    Observing quantum behavior of mechanical motion is challenging because it is difficult both to prepare pure quantum states of motion and to detect those states with high enough precision. We present displacement measurements of a nanomechanical oscillator with an imprecision below that at the standard quantum limit [1]. To achieve this, we couple the motion of the oscillator to the microwave field in a high-Q superconducting resonant circuit. The oscillator's displacement imprints a phase modulation on the microwave signal. We attain the low imprecision by reading out the modulation with a Josephson Parametric Amplifier, realizing a microwave interferometer that operates near the shot-noise limit. The apparent motion of the mechanical oscillator due the interferometer's noise is now substantially less than its zero-point motion, making future detection of quantum states feasible. In addition, the phase sensitivity of the demonstrated interferometer is 30 times higher than previous microwave interferometers, providing a critical piece of technology for many experiments investigating quantum information encoded in microwave fields. [4pt] [1] J. D. Teufel, T. Donner, M. A. Castellanos-Beltran, J. W. Harlow, K. W. Lehnert, Nature Nanotechnology, doi:10.1038/nnano.2009.343, (2009).

  3. Angle-independent measure of motion for image-based gating in 3D coronary angiography

    SciTech Connect

    Lehmann, Glen C.; Holdsworth, David W.; Drangova, Maria

    2006-05-15

    The role of three-dimensional (3D) image guidance for interventional procedures and minimally invasive surgeries is increasing for the treatment of vascular disease. Currently, most interventional procedures are guided by two-dimensional x-ray angiography, but computed rotational angiography has the potential to provide 3D geometric information about the coronary arteries. The creation of 3D angiographic images of the coronary arteries requires synchronization of data acquisition with respect to the cardiac cycle, in order to minimize motion artifacts. This can be achieved by inferring the extent of motion from a patient's electrocardiogram (ECG) signal. However, a direct measurement of motion (from the 2D angiograms) has the potential to improve the 3D angiographic images by ensuring that only projections acquired during periods of minimal motion are included in the reconstruction. This paper presents an image-based metric for measuring the extent of motion in 2D x-ray angiographic images. Adaptive histogram equalization was applied to projection images to increase the sharpness of coronary arteries and the superior-inferior component of the weighted centroid (SIC) was measured. The SIC constitutes an image-based metric that can be used to track vessel motion, independent of apparent motion induced by the rotational acquisition. To evaluate the technique, six consecutive patients scheduled for routine coronary angiography procedures were studied. We compared the end of the SIC rest period ({rho}) to R-waves (R) detected in the patient's ECG and found a mean difference of 14{+-}80 ms. Two simultaneous angular positions were acquired and {rho} was detected for each position. There was no statistically significant difference (P=0.79) between {rho} in the two simultaneously acquired angular positions. Thus we have shown the SIC to be independent of view angle, which is critical for rotational angiography. A preliminary image-based gating strategy that employed the SIC

  4. Advances in Fast Response Acoustically Derived Air Temperature Measurements

    NASA Astrophysics Data System (ADS)

    Bogoev, Ivan; Jacobsen, Larry; Horst, Thomas; Conrad, Benjamin

    2016-04-01

    Fast-response accurate air-temperature measurements are required when estimating turbulent fluxes of heat, water and carbon dioxide by open-path eddy-covariance technique. In comparison with contact thermometers like thermocouples, ultra-sonic thermometers do not suffer from solar radiation loading, water vapor condensation and evaporative cooling effects. Consequently they have the potential to provide more accurate true air temperature measurements. The absolute accuracy of the ultrasonic thermometer is limited by the following parameters: the distance between the transducer pairs, transducer delays associated with the electrical-acoustic signal conversion that vary with temperature, components of the wind vector that are normal to the ultrasonic paths, and humidity. The distance between the transducer pairs is commonly obtained by coordinate measuring machine. Improved accuracy demonstrated in this study results from increased stiffness in the anemometer head to better maintain the ultrasonic path-length distances. To further improve accuracy and account for changes in transducer delays and distance as a function of temperature, these parameters are characterized in a zero-wind chamber over the entire operating temperature range. When the sonic anemometer is combined with a co-located fast-response water vapor analyzer, like in the IRGASON instrument, speed of sound can be compensated for humidity effects on a point-by-point basis resulting in a true fast-response air temperature measurement. Laboratory test results show that when the above steps are implemented in the calibration of the ultrasonic thermometer air-temperature accuracy better than ±0.5 degrees Celsius can be achieved over the entire operating range. The approach is also validated in a field inter-comparison with an aspirated thermistor probe mounted in a radiation shield.

  5. Measuring Density Of Air By Ultraviolet Rayleigh Scattering

    NASA Technical Reports Server (NTRS)

    Mckenzie, Robert L.

    1992-01-01

    Report presents theoretical and experimental studies directed toward development of optoelectronic instrument to measure density of air at altitudes from 50 to 90 km and possibly beyond. Instrument mounted in Space Shuttle orbiter and operated during reentry into atmosphere. Data gathered by instrument needed because density of upper atmosphere highly variable in space and time and this variability affects aerodynamic behavior and trajectory of reentering Shuttle. Variations in density also meteorologically significant.

  6. Simultaneous measurement of mass and rotation of trapped absorbing particles in air.

    PubMed

    Bera, Sudipta K; Kumar, Avinash; Sil, Souvik; Saha, Tushar Kanti; Saha, Tanumoy; Banerjee, Ayan

    2016-09-15

    We trap absorbing micro-particles in air by photophoretic forces generated using a single loosely focused Gaussian trapping beam. We measure a component of the radial Brownian motion of a trapped particle cluster and determine the power spectral density, mean squared displacement, and normalized position and velocity autocorrelation functions to characterize the photophoretic body force in a quantitative fashion for the first time. The trapped particles also undergo spontaneous rotation due to the action of this force. This is evident from the spectral density that displays clear peaks at the rotation and the particles' inertial resonance frequencies. We fit the spectral density to the well-known analytical function derived from the Langevin equation, measure the resonance and rotation frequencies, and determine the values for particle mass that we verify at different trapping laser powers with reasonable accuracy. PMID:27628396

  7. Air infiltration and building tightness measurements in passive solar residences

    SciTech Connect

    Persily, A.K.; Grot, R.A.

    1984-05-01

    The airtightness of about fifty passive solar homes located throughout the United States was studied using low-cost measurement techniques. These homes are part of the DOE-sponsored Class B monitoring program conducted at the Solar Energy Research Institute (SERI) to evaluate the thermal performance of passive solar residential buildings. These tests provide the first set of building tightness measurements on a large group of passive solar buildings. The measurements include pressurization tests to measure airtightness and tracer gas measurements to determine air infiltration rates. The pressure tests show a variation in the airtightness of these homes from 3 to 30 exchanges/hr at 50 Pascal, with a median of 9.5 exchanges/hr. The air infiltration measurements cover a wider range from 0.05 to 3.0 exchanges/hr, with a median of 0.5 exchanges/hr. In comparing the tightness of these homes to other U.S. homes, one finds that these passive solar homes are not significantly tighter than homes built with less of an emphasis on energy use.

  8. Radio Emission in Atmospheric Air Showers Measured by LOPES-30

    SciTech Connect

    Isar, P. G.

    2008-01-24

    When Ultra High Energy Cosmic Rays (UHECR) interact with particles in the Earth's atmosphere, they produce a shower of secondary particles propagating towards the ground. These relativistic particles emit synchrotron radiation in the radio frequency range when passing the Earth's magnetic field. The LOPES (LOFAR Prototype Station) experiment investigates the radio emission from these showers in detail and will pave the way to use this detection technique for large scale applications like in LOFAR (Low Frequency Array) and the Pierre Auger Observatory. The LOPES experiment is co-located and measures in coincidence with the air shower experiment KASCADE-Grande at Forschungszentrum Karlsruhe, Germany. LOPES has an absolute amplitude calibration array of 30 dipole antennas (LOPES-30). After one year of measurements of the single East-West polarization by all 30 antennas, recently, the LOPES-30 set-up was configured to perform dual-polarization measurements. Half of the antennas have been configured for measurements of the North-South polarization. Only by measuring at the same time both, the E-W and N-S polarization components of the radio emission, the geo-synchrotron effect as the dominant emission mechanism in air showers can be verified. The status of the measurements, including the absolute calibration procedure of the dual-polarized antennas as well as analysis of dual-polarized event examples are reported.

  9. PAH Measurements in Air in the Athabasca Oil Sands Region.

    PubMed

    Hsu, Yu-Mei; Harner, Tom; Li, Henrik; Fellin, Phil

    2015-05-01

    Polycyclic aromatic hydrocarbon (PAH) measurements were conducted by Wood Buffalo Environmental Association (WBEA) at four community ambient Air quality Monitoring Stations (AMS) in the Athabasca Oil Sands Region (AOSR) in Northeastern Alberta, Canada. The 2012 and 2013 mean concentrations of a subset of the 22 PAH species were 9.5, 8.4, 8.8, and 32 ng m(-3) at AMS 1 (Fort McKay), AMS 6 (residential Fort McMurray), AMS 7 (downtown Fort McMurray), and AMS 14 (Anzac), respectively. The average PAH concentrations in Fort McKay and Fort McMurray were in the range of rural and semirural areas, but peak values reflect an industrial emission influence. At these stations, PAHs were generally associated with NO, NO2, PM2.5, and SO2, indicating the emissions were from the combustion sources such as industrial stacks, vehicles, residential heating, and forest fires, whereas the PAH concentrations at AMS 14 (∼35 km south of Fort McMurray) were more characteristic of urban areas with a unique pattern: eight of the lower molecular weight PAHs exhibited strong seasonality with higher levels during the warmer months. Enthalpies calculated from Clausius-Clapeyron plots for these eight PAHs suggest that atmospheric emissions were dominated by temperature-dependent processes such as volatilization at warm temperatures. These findings point to the potential importance of localized water-air and/or surface-air transfer on observed PAH concentrations in air.

  10. PAH Measurements in Air in the Athabasca Oil Sands Region.

    PubMed

    Hsu, Yu-Mei; Harner, Tom; Li, Henrik; Fellin, Phil

    2015-05-01

    Polycyclic aromatic hydrocarbon (PAH) measurements were conducted by Wood Buffalo Environmental Association (WBEA) at four community ambient Air quality Monitoring Stations (AMS) in the Athabasca Oil Sands Region (AOSR) in Northeastern Alberta, Canada. The 2012 and 2013 mean concentrations of a subset of the 22 PAH species were 9.5, 8.4, 8.8, and 32 ng m(-3) at AMS 1 (Fort McKay), AMS 6 (residential Fort McMurray), AMS 7 (downtown Fort McMurray), and AMS 14 (Anzac), respectively. The average PAH concentrations in Fort McKay and Fort McMurray were in the range of rural and semirural areas, but peak values reflect an industrial emission influence. At these stations, PAHs were generally associated with NO, NO2, PM2.5, and SO2, indicating the emissions were from the combustion sources such as industrial stacks, vehicles, residential heating, and forest fires, whereas the PAH concentrations at AMS 14 (∼35 km south of Fort McMurray) were more characteristic of urban areas with a unique pattern: eight of the lower molecular weight PAHs exhibited strong seasonality with higher levels during the warmer months. Enthalpies calculated from Clausius-Clapeyron plots for these eight PAHs suggest that atmospheric emissions were dominated by temperature-dependent processes such as volatilization at warm temperatures. These findings point to the potential importance of localized water-air and/or surface-air transfer on observed PAH concentrations in air. PMID:25844542

  11. Experimental measurement of human head motion for high-resolution computed tomography system design

    NASA Astrophysics Data System (ADS)

    Li, Liang; Chen, Zhiqiang; Jin, Xin; Yu, Hengyong; Wang, Ge

    2010-06-01

    Human head motion has been experimentally measured for high-resolution computed tomography (CT) design using a Canon digital camera. Our goal is to identify the minimal movements of the human head under ideal conditions without rigid fixation. In our experiments, all the 19 healthy volunteers were lying down with strict self-control. All of them were asked to be calm without pressures. Our results showed that the mean absolute value of the measured translation excursion was about 0.35 mm, which was much less than the measurements on real patients. Furthermore, the head motions in different directions were correlated. These results are useful for the design of the new instant CT system for in vivo high-resolution imaging (about 40 μm).

  12. Measurement of ion motional heating rates over a range of trap frequencies and temperatures

    NASA Astrophysics Data System (ADS)

    Bruzewicz, C. D.; Sage, J. M.; Chiaverini, J.

    2015-04-01

    We present measurements of the motional heating rate of a trapped ion at different trap frequencies and temperatures between ˜0.6 and 1.5 MHz and ˜4 and 295 K. Additionally, we examine the possible effect of adsorbed surface contaminants with boiling points below ˜105 ∘C by measuring the ion heating rate before and after locally baking our ion trap chip under ultrahigh vacuum conditions. We compare the heating rates presented here to those calculated from available electric-field noise models. We can tightly constrain a subset of these models based on their expected frequency and temperature scaling interdependence. Discrepancies between the measured results and predicted values point to the need for refinement of theoretical noise models in order to more fully understand the mechanisms behind motional trapped-ion heating.

  13. A FIRST MEASUREMENT OF THE PROPER MOTION OF THE LEO II DWARF SPHEROIDAL GALAXY

    SciTech Connect

    Lepine, Sebastien; Koch, Andreas; Rich, R. Michael; Kuijken, Konrad

    2011-11-10

    We use 14 year baseline images obtained with the Wide Field and Planetary Camera 2 on board the Hubble Space Telescope (HST) to derive a proper motion for one of the Milky Way's most distant dwarf spheroidal companions, Leo II, relative to an extragalactic background reference frame. Astrometric measurements are performed in the effective point-spread function formalism using our own developed code. An astrometric reference grid is defined using 3224 stars that are members of Leo II and brighter than a magnitude of 25 in the F814W band. We identify 17 compact extragalactic sources, for which we measure a systemic proper motion relative to this stellar reference grid. We derive a proper motion [{mu}{sub {alpha},{mu}{delta}}] = [+104 {+-}113,-33 {+-} 151] {mu}as yr{sup -1} for Leo II in the heliocentric reference frame. Though marginally detected, the proper motion yields constraints on the orbit of Leo II. Given a distance of d {approx_equal} 230 kpc and a heliocentric radial velocity v{sub r} = +79 km s{sup -1}, and after subtraction of the solar motion, our measurement indicates a total orbital motion v{sub G} = 266.1 {+-} 128.7 km s{sup -1} in the Galactocentric reference frame, with a radial component v{sub r{sub G}}=21.5{+-}4.3 km s{sup -1} and tangential component v{sub t{sub G}} = 265.2 {+-} 129.4 km s{sup -1}. The small radial component indicates that Leo II either has a low-eccentricity orbit or is currently close to perigalacticon or apogalacticon distance. We see evidence for systematic errors in the astrometry of the extragalactic sources which, while close to being point sources, are slightly resolved in the HST images. We argue that more extensive observations at later epochs will be necessary to better constrain the proper motion of Leo II. We provide a detailed catalog of the stellar and extragalactic sources identified in the HST data which should provide a solid early-epoch reference for future astrometric measurements.

  14. MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning

    NASA Astrophysics Data System (ADS)

    Blackall, J. M.; Ahmad, S.; Miquel, M. E.; McClelland, J. R.; Landau, D. B.; Hawkes, D. J.

    2006-09-01

    Respiratory organ motion has a significant impact on the planning and delivery of radiotherapy (RT) treatment for lung cancer. Currently widespread techniques, such as 4D-computed tomography (4DCT), cannot be used to measure variability of this motion from one cycle to the next. In this paper, we describe the use of fast magnetic resonance imaging (MRI) techniques to investigate the intra- and inter-cycle reproducibility of respiratory motion and also to estimate the level of errors that may be introduced into treatment delivery by using various breath-hold imaging strategies during lung RT planning. A reference model of respiratory motion is formed to enable comparison of different breathing cycles at any arbitrary position in the respiratory cycle. This is constructed by using free-breathing images from the inhale phase of a single breathing cycle, then co-registering the images, and thereby tracking landmarks. This reference model is then compared to alternative models constructed from images acquired during the exhale phase of the same cycle and the inhale phase of a subsequent cycle, to assess intra- and inter-cycle variability ('hysteresis' and 'reproducibility') of organ motion. The reference model is also compared to a series of models formed from breath-hold data at exhale and inhale. Evaluation of these models is carried out on data from ten healthy volunteers and five lung cancer patients. Free-breathing models show good levels of intra- and inter-cycle reproducibility across the tidal breathing range. Mean intra-cycle errors in the position of organ surface landmarks of 1.5(1.4)-3.5(3.3) mm for volunteers and 2.8(1.8)-5.2(5.2) mm for patients. Equivalent measures of inter-cycle variability across this range are 1.7(1.0)-3.9(3.3) mm for volunteers and 2.8(1.8)-3.3(2.2) mm for patients. As expected, models based on breath-hold sequences do not represent normal tidal motion as well as those based on free-breathing data, with mean errors of 4

  15. Motion of tympanic membrane in guinea pig otitis media model measured by scanning laser Doppler vibrometry.

    PubMed

    Wang, Xuelin; Guan, Xiying; Pineda, Mario; Gan, Rong Z

    2016-09-01

    Otitis media (OM) is an inflammatory or infectious disease of the middle ear. Acute otitis media (AOM) and otitis media with effusion (OME) are the two major types of OM. However, the tympanic membrane (TM) motion differences induced by AOM and OME have not been quantified in animal models in the literature. In this study, the guinea pig AOM and OME models were created by transbullar injection of Streptococcus pneumoniae type 3 and lipopolysaccharide, respectively. To explore the effects of OM on the entire TM vibration, the measurements of full-field TM motions were performed in the AOM, OME and untreated control ears by using scanning laser Doppler vibrometry (SLDV). The results showed that both AOM and OME generally reduced the displacement peak and produced the traveling-wave-like motions at relatively low frequencies. Compared with the normal ear, OME resulted in a significant change of the TM displacement mainly in the inferior portion of the TM, and AOM significantly affected the surface motion across four quadrants. The SLDV measurements provide more insight into sound-induced TM vibration in diseased ears. PMID:27490002

  16. Effects of five hindfoot arthrodeses on foot and ankle motion: Measurements in cadaver specimens

    PubMed Central

    Zhang, Kun; Chen, Yanxi; Qiang, Minfei; Hao, Yini

    2016-01-01

    Single, double, and triple hindfoot arthrodeses are used to correct hindfoot deformities and relieve chronic pain. However, joint fusion may lead to dysfunction in adjacent articular surfaces. We compared range of motion in adjacent joints before and after arthrodesis to determine the effects of each procedure on joint motion. The theory of moment of couple, bending moment and balanced loading was applied to each of 16 fresh cadaver feet to induce dorsiflexion, plantarflexion, internal rotation, external rotation, inversion, and eversion. Range of motion was measured with a 3-axis coordinate measuring machine in a control foot and in feet after subtalar, talonavicular, calcaneocuboid, double, or triple arthrodesis. All arthrodeses restricted mainly internal-external rotation and inversion-eversion. The restriction in a double arthrodesis was more than that in a single arthrodesis, but that in a calcaneocuboid arthrodesis was relatively low. After triple arthrodeses, the restriction on dorsiflexion and plantarflexion movements was substantial, and internal-external rotation and inversion-eversion were almost lost. Considering that different arthrodesis procedures cause complex, three-dimensional hindfoot motion reductions, we recommend talonavicular or calcaneocuboid arthrodesis for patients with well-preserved functions of plantarflexion/dorsiflexion before operation, subtalar or calcaneocuboid arthrodesis for patients with well-preserved abduction/adduction, and talonavicular arthrodesis for patients with well-preserved eversion/inversion. PMID:27752084

  17. Horizontal crustal motion in the central and eastern Mediterranean inferred from Satellite Laser Ranging measurements

    SciTech Connect

    Smith, D.E.; Kolenkiewicz, R.; Robbins, J.W.; Dunn, P.J.; Torrence, M.H. |

    1994-09-01

    Four campaigns to acquire Satellite Laser Ranging (SLR) measurements at sites in the Mediterranean region have been completed. These measurements to the LAGEOS satellite, made largely by mobile systems, cover a time span beginning in November 1985 and ending in June 1993. The range data from 18 sites in the central and eastern Mediterranean have been simultaneously analyzed with data acquired by the remainder of the global laser tracking network. Estimates of horizontal motion were placed into a regional, northern Europe-fixed, kinematic reference frame. Uncertainties are on the order of 5 mm/yr for sites having at least four occupations by mobile systems and approach 1 mm/yr for permanently located sites with long histories of tracking. The resulting relative motion between sites in the Aegean exhibit characteristics of broadly distributed pattern of radial extension, but at rates that are about 50% larger than those implied from studies of seismic strain rates based on seismicity of magnitude 6 or greater or across the region. The motion estimated for sites in Turkey exhibit velocity components associated with the westward motion of the Anatolian Block relative to Eurasia. These results provide a present-day `snapshot` of ongoing deformational processes as experienced by the locations occupied by SLR systems.

  18. Linking criteria for incipient motion to field-based measures of bed load transport capacity

    NASA Astrophysics Data System (ADS)

    Pitlick, J.

    2015-12-01

    Early studies of sediment transport, such as those of Gilbert (1914) and Shields (1936), laid the groundwork for countless other studies of bed load entrainment and transport. Gilbert and Shields emphasized somewhat different aspects of sediment transport in their writing, but they had similar objectives in experimenting with conditions that affect both incipient motion and bed load transport capacity. The problem of predicting incipient motion is thus inextricably linked to the problem of predicting bed load transport capacity. In this talk I will discuss field-based approaches for evaluating incipient motion at channel-length scales ranging from a few km to many 10s of km. In the best-case scenario, where time and equipment are available to sample the bed load, the most robust approach for determining incipient motion is to extrapolate from measurements taken over a range of flows, and find the shear stress corresponding to a low but measureable transport rate. Alternatively, if channel properties (width, depth, slope and grain size) can be measured at a sufficient number of locations (say, more than 20), the reference shear stress can be estimated by assuming it scales with the channel-forming (bankfull) shear stress. Another new approach, which makes use of repeat aerial LiDAR and records of daily discharge, is to develop a two-parameter sediment rating curve that produces the same sediment flux for a time series of daily flows as the sediment flux estimated from topographic differencing. Last, in situations where a qualitative (yes/no) assessment of sediment motion is sufficient (e.g. during a reservoir release), longitudinal variations in bed load transport intensity can be detected with acoustical sensors- hydrophones- mounted on a kayak or boat equipped with a global positioning system (GPS). Pros and cons of these different approaches will also be discussed.

  19. Bias in air sampling techniques used to measure inhalation exposure.

    PubMed

    Cohen, B S; Harley, N H; Lippmann, M

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and "mini hi-volume" samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. We conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages.

  20. Bias in air sampling techniques used to measure inhalation exposure

    SciTech Connect

    Cohen, B.S.; Harley, N.H.; Lippmann, M.

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and mini hi-volume samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. The authors conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages.

  1. Integrated Assessment of Air Pollution Control Measures for Megacities

    NASA Astrophysics Data System (ADS)

    Friedrich, R.; Theloke, J.; Denier-van-der-Gon, H.; Kugler, U.; Kampffmeyer, T.; Roos, J.; Torras, S.

    2012-04-01

    Air pollution in large cities is still a matter of concern. Especially the concentration of fine particles (PM10 and PM2.5) is largest in large cities leading to severe health impacts. Furthermore the PM10 thresholds of the EU Air Quality Directive are frequently exceeded. Thus the question arises, whether the initiated policies and measures for mitigating air pollution are sufficient to meet the air quality targets and - if not - which efficient further pollution mitigation measures exist. These questions have been addressed in the EU research project MEGAPOLI for the four European megacities respectively agglomerations London, Paris, Rhine-Ruhr area and Po valley. Firstly, a reference scenario of future activities and emissions has been compiled for the megacities for the years 2020, 2030 and 2050 for all relevant air pollutants (CO, NH3, NMVOC, NOx, PM10, PM2.5 and SO2) and greenhouse gases (CO2, CH4 and N2O). The reference scenario takes into account as well population changes as technical progress and economic growth. As pollution flowing in from outside the city is about as important as pollution caused by emissions in the city, the analysis covers the whole of Europe and not only the city area. Emissions are then transformed into concentrations using atmospheric models. The higher concentrations in cities were estimated with a newly developed 'urban increment' model. Results show, that in the megacities the limits of the Air Quality Directive (2008/50/EC) will be exceeded. Thus additional efforts are necessary to reduce emissions further. Thus, a number of further measures (not implemented in current legislation) were selected and assessed. These included mitigation options for road transport, other mobile sources, large combustion plants, small and medium combustion plants and industry. For each measure and in addition for various bundles of measures a cost-benefit analysis has been carried out. Benefits (avoided health risks and climate change risks) have

  2. Prototype Systems for Measuring Outdoor Air Intake Rates in Rooftop Air Handlers

    SciTech Connect

    Fisk, William J.; Chan, Wanyu R.; Hotchi, Toshifumi

    2015-01-01

    The widespread absence of systems for real-time measurement and feedback control, of minimum outdoor air intake rates in HVAC systems contributes to the poor control of ventilation rates in commercial buildings. Ventilation rates affect building energy consumption and influence occupant health. The project designed fabricated and tested four prototypes of systems for measuring rates of outdoor air intake into roof top air handlers. All prototypes met the ±20% accuracy target at low wind speeds, with all prototypes accurate within approximately ±10% after application of calibration equations. One prototype met the accuracy target without a calibration. With two of four prototype measurement systems, there was no evidence that wind speed or direction affected accuracy; however, winds speeds were generally below usually 3.5 m s-1 (12.6 km h-1) and further testing is desirable. The airflow resistance of the prototypes was generally less than 35 Pa at maximum RTU air flow rates. A pressure drop of this magnitude will increase fan energy consumption by approximately 4%. The project did not have resources necessary to estimate costs of mass produced systems. The retail cost of components and materials used to construct prototypes ranged from approximately $1,200 to $1,700. The test data indicate that the basic designs developed in this project, particularly the designs of two of the prototypes, have considerable merit. Further design refinement, testing, and cost analysis would be necessary to fully assess commercial potential. The designs and test results will be communicated to the HVAC manufacturing community.

  3. Low-Cost Sensor Units for Measuring Urban Air Quality

    NASA Astrophysics Data System (ADS)

    Popoola, O. A.; Mead, M.; Stewart, G.; Hodgson, T.; McLoed, M.; Baldovi, J.; Landshoff, P.; Hayes, M.; Calleja, M.; Jones, R.

    2010-12-01

    Measurements of selected key air quality gases (CO, NO & NO2) have been made with a range of miniature low-cost sensors based on electrochemical gas sensing technology incorporating GPS and GPRS for position and communication respectively. Two types of simple to operate sensors units have been designed to be deployed in relatively large numbers. Mobile handheld sensor units designed for operation by members of the public have been deployed on numerous occasions including in Cambridge, London and Valencia. Static sensor units have also been designed for long-term autonomous deployment on existing street furniture. A study was recently completed in which 45 sensor units were deployed in the Cambridge area for a period of 3 months. Results from these studies indicate that air quality varies widely both spatially and temporally. The widely varying concentrations found suggest that the urban environment cannot be fully understood using limited static site (AURN) networks and that a higher resolution, more dispersed network is required to better define air quality in the urban environment. The results also suggest that higher spatial and temporal resolution measurements could improve knowledge of the levels of individual exposure in the urban environment.

  4. Air Quality Science and Regulatory Efforts Require Geostationary Satellite Measurements

    NASA Technical Reports Server (NTRS)

    Pickering, Kenneth E.; Allen, D. J.; Stehr, J. W.

    2006-01-01

    Air quality scientists and regulatory agencies would benefit from the high spatial and temporal resolution trace gas and aerosol data that could be provided by instruments on a geostationary platform. More detailed time-resolved data from a geostationary platform could be used in tracking regional transport and in evaluating mesoscale air quality model performance in terms of photochemical evolution throughout the day. The diurnal cycle of photochemical pollutants is currently missing from the data provided by the current generation of atmospheric chemistry satellites which provide only one measurement per day. Often peak surface ozone mixing ratios are reached much earlier in the day during major regional pollution episodes than during local episodes due to downward mixing of ozone that had been transported above the boundary layer overnight. The regional air quality models often do not simulate this downward mixing well enough and underestimate surface ozone in regional episodes. Having high time-resolution geostationary data will make it possible to determine the magnitude of this lower-and mid-tropospheric transport that contributes to peak eight-hour average ozone and 24-hour average PM2.5 concentrations. We will show ozone and PM(sub 2.5) episodes from the CMAQ model and suggest ways in which geostationary satellite data would improve air quality forecasting. Current regulatory modeling is typically being performed at 12 km horizontal resolution. State and regional air quality regulators in regions with complex topography and/or land-sea breezes are anxious to move to 4-km or finer resolution simulations. Geostationary data at these or finer resolutions will be useful in evaluating such models.

  5. Use of Oriented Spray Nozzles to Set the Vapor-Air Flow in Rotary Motion in the Superspray Space of the Evaporative Chimney-Type Tower

    NASA Astrophysics Data System (ADS)

    Dobrego, K. V.; Davydenko, V. F.; Koznacheev, I. A.

    2016-01-01

    The present paper considers the problem of upgrading the thermal efficiency of chimney-type evaporative cooling towers due to the rotary motion of the vapor-air flow in the superspray space. To set the vapor-air flow in rotary motion, we propose to use the momentum of the sprayed water. It has been shown that the existing parameters of spray nozzles permit setting up to 30% of the water flow momentum in translatory motion, which is enough for changing considerably the aerodynamics of the vapor-air flow in the superspray space and improving the operation of the cooling tower. The optimal angle of axial inclination of the spray cone has been estimated. Recommendations are given and problems have been posed for engineering realization of the proposed technologies in a chimney-type cooling tower.

  6. SCANNING VOLTA POTENTIALS MEASUREMENTS OF METALS IN IRRADIATED AIR.

    SciTech Connect

    ISAACS, H.S.; ADZIC, G.; AND ENERGY SCIENCES AND TECHNOLOGY DEPARTMENT; JEFFCOATE, C.S.

    2000-10-22

    A method for direct dc measurement of the Volta potential is presented. High intensity synchrotron x-ray beams were used to locally irradiate the atmosphere adjacent to the metal surface and produce a conducting path between a sample and a reference probe. The direct measurements of potential in the ionized air could be made at probe heights of around 1 mm compared to less than 0.1 mm for the Kelvin probe. The measurements were similar to traditional Kelvin probe measurements, but had a poorer spatial resolution. In contrast to the Kelvin probe methods, the approach described allows observation of the current as a function of impressed voltage. Methods to improve the special resolution of the technique and applications to corrosion under coating will be presented.

  7. Air

    MedlinePlus

    ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be polluted indoors and it can ... this chart to see what things cause indoor air pollution and what things cause outdoor air pollution! Indoor ...

  8. Angular Motion Estimation Using Dynamic Models in a Gyro-Free Inertial Measurement Unit

    PubMed Central

    Edwan, Ezzaldeen; Knedlik, Stefan; Loffeld, Otmar

    2012-01-01

    In this paper, we summarize the results of using dynamic models borrowed from tracking theory in describing the time evolution of the state vector to have an estimate of the angular motion in a gyro-free inertial measurement unit (GF-IMU). The GF-IMU is a special type inertial measurement unit (IMU) that uses only a set of accelerometers in inferring the angular motion. Using distributed accelerometers, we get an angular information vector (AIV) composed of angular acceleration and quadratic angular velocity terms. We use a Kalman filter approach to estimate the angular velocity vector since it is not expressed explicitly within the AIV. The bias parameters inherent in the accelerometers measurements' produce a biased AIV and hence the AIV bias parameters are estimated within an augmented state vector. Using dynamic models, the appended bias parameters of the AIV become observable and hence we can have unbiased angular motion estimate. Moreover, a good model is required to extract the maximum amount of information from the observation. Observability analysis is done to determine the conditions for having an observable state space model. For higher grades of accelerometers and under relatively higher sampling frequency, the error of accelerometer measurements is dominated by the noise error. Consequently, simulations are conducted on two models, one has bias parameters appended in the state space model and the other is a reduced model without bias parameters. PMID:22778586

  9. Probing the radio emission from air showers with polarization measurements

    NASA Astrophysics Data System (ADS)

    Aab, A.; Abreu, P.; Aglietta, M.; Ahlers, M.; Ahn, E. J.; Albuquerque, I. F. M.; Allekotte, I.; Allen, J.; Allison, P.; Almela, A.; Alvarez Castillo, J.; Alvarez-Muñiz, J.; Alves Batista, R.; Ambrosio, M.; Aminaei, A.; Anchordoqui, L.; Andringa, S.; Antičić, T.; Aramo, C.; Arqueros, F.; Asorey, H.; Assis, P.; Aublin, J.; Ave, M.; Avenier, M.; Avila, G.; Badescu, A. M.; Barber, K. B.; Bardenet, R.; Bäuml, J.; Baus, C.; Beatty, J. J.; Becker, K. H.; Bellido, J. A.; BenZvi, S.; Berat, C.; Bertou, X.; Biermann, P. L.; Billoir, P.; Blanco, F.; Blanco, M.; Bleve, C.; Blümer, H.; Boháčová, M.; Boncioli, D.; Bonifazi, C.; Bonino, R.; Borodai, N.; Brack, J.; Brancus, I.; Brogueira, P.; Brown, W. C.; Buchholz, P.; Bueno, A.; Buscemi, M.; Caballero-Mora, K. S.; Caccianiga, B.; Caccianiga, L.; Candusso, M.; Caramete, L.; Caruso, R.; Castellina, A.; Cataldi, G.; Cazon, L.; Cester, R.; Cheng, S. H.; Chiavassa, A.; Chinellato, J. A.; Chudoba, J.; Cilmo, M.; Clay, R. W.; Cocciolo, G.; Colalillo, R.; Collica, L.; Coluccia, M. R.; Conceição, R.; Contreras, F.; Cooper, M. J.; Coutu, S.; Covault, C. E.; Criss, A.; Cronin, J.; Curutiu, A.; Dallier, R.; Daniel, B.; Dasso, S.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; De Domenico, M.; de Jong, S. J.; De La Vega, G.; de Mello Junior, W. J. M.; de Mello Neto, J. R. T.; De Mitri, I.; de Souza, V.; de Vries, K. D.; del Peral, L.; Deligny, O.; Dembinski, H.; Dhital, N.; Di Giulio, C.; Di Matteo, A.; Diaz, J. C.; Díaz Castro, M. L.; Diep, P. N.; Diogo, F.; Dobrigkeit, C.; Docters, W.; D'Olivo, J. C.; Dong, P. N.; Dorofeev, A.; dos Anjos, J. C.; Dova, M. T.; Ebr, J.; Engel, R.; Erdmann, M.; Escobar, C. O.; Espadanal, J.; Etchegoyen, A.; Facal San Luis, P.; Falcke, H.; Fang, K.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Ferguson, A. P.; Fick, B.; Figueira, J. M.; Filevich, A.; Filipčič, A.; Foerster, N.; Fox, B. D.; Fracchiolla, C. E.; Fraenkel, E. D.; Fratu, O.; Fröhlich, U.; Fuchs, B.; Gaior, R.; Gamarra, R. F.; Gambetta, S.; García, B.; Garcia Roca, S. T.; Garcia-Gamez, D.; Garcia-Pinto, D.; Garilli, G.; Gascon Bravo, A.; Gemmeke, H.; Ghia, P. L.; Giammarchi, M.; Giller, M.; Gitto, J.; Glaser, C.; Glass, H.; Gomez Albarracin, F.; Gómez Berisso, M.; Gómez Vitale, P. F.; Gonçalves, P.; Gonzalez, J. G.; Gookin, B.; Gorgi, A.; Gorham, P.; Gouffon, P.; Grebe, S.; Griffith, N.; Grillo, A. F.; Grubb, T. D.; Guardincerri, Y.; Guarino, F.; Guedes, G. P.; Hansen, P.; Harari, D.; Harrison, T. A.; Harton, J. L.; Haungs, A.; Hebbeker, T.; Heck, D.; Herve, A. E.; Hill, G. C.; Hojvat, C.; Hollon, N.; Holt, E.; Homola, P.; Hörandel, J. R.; Horvath, P.; Hrabovský, M.; Huber, D.; Huege, T.; Insolia, A.; Isar, P. G.; Jansen, S.; Jarne, C.; Josebachuili, M.; Kadija, K.; Kambeitz, O.; Kampert, K. H.; Karhan, P.; Kasper, P.; Katkov, I.; Kégl, B.; Keilhauer, B.; Keivani, A.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Knapp, J.; Krause, R.; Krohm, N.; Krömer, O.; Kruppke-Hansen, D.; Kuempel, D.; Kunka, N.; La Rosa, G.; LaHurd, D.; Latronico, L.; Lauer, R.; Lauscher, M.; Lautridou, P.; Le Coz, S.; Leão, M. S. A. B.; Lebrun, D.; Lebrun, P.; Leigui de Oliveira, M. A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Link, K.; López, R.; Lopez Agüera, A.; Louedec, K.; Lozano Bahilo, J.; Lu, L.; Lucero, A.; Ludwig, M.; Lyberis, H.; Maccarone, M. C.; Malacari, M.; Maldera, S.; Maller, J.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Marin, V.; Mariş, I. C.; Marquez Falcon, H. R.; Marsella, G.; Martello, D.; Martin, L.; Martinez, H.; Martínez Bravo, O.; Martraire, D.; Masías Meza, J. J.; Mathes, H. J.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Maurel, D.; Maurizio, D.; Mayotte, E.; Mazur, P. O.; Medina, C.; Medina-Tanco, G.; Melissas, M.; Melo, D.; Menichetti, E.; Menshikov, A.; Messina, S.; Meyhandan, R.; Mićanović, S.; Micheletti, M. I.; Middendorf, L.; Minaya, I. A.; Miramonti, L.; Mitrica, B.; Molina-Bueno, L.; Mollerach, S.; Monasor, M.; Monnier Ragaigne, D.; Montanet, F.; Morales, B.; Morello, C.; Moreno, J. C.; Mostafá, M.; Moura, C. A.; Muller, M. A.; Müller, G.; Münchmeyer, M.; Mussa, R.; Navarra, G.; Navarro, J. L.; Navas, S.; Necesal, P.; Nellen, L.; Nelles, A.; Neuser, J.; Nhung, P. T.; Niechciol, M.; Niemietz, L.; Niggemann, T.; Nitz, D.; Nosek, D.; Nožka, L.; Oehlschläger, J.; Olinto, A.; Oliveira, M.; Ortiz, M.; Pacheco, N.; Pakk Selmi-Dei, D.; Palatka, M.; Pallotta, J.; Palmieri, N.; Parente, G.; Parra, A.; Pastor, S.; Paul, T.; Pech, M.; PeÂķala, J.; Pelayo, R.; Pepe, I. M.; Perrone, L.; Pesce, R.; Petermann, E.; Petrera, S.; Petrolini, A.; Petrov, Y.; Piegaia, R.; Pierog, T.; Pieroni, P.; Pimenta, M.; Pirronello, V.; Platino, M.; Plum, M.; Pontz, M.; Porcelli, A.; Preda, T.; Privitera, P.; Prouza, M.; Quel, E. J.; Querchfeld, S.; Quinn, S.; Rautenberg, J.; Ravel, O.; Ravignani, D.; Revenu, B.; Ridky, J.; Riggi, S.; Risse, M.; Ristori, P.; Rivera, H.; Rizi, V.; Roberts, J.; Rodrigues de Carvalho, W.; Rodriguez Cabo, I.; Rodriguez Fernandez, G.; Rodriguez Martino, J.; Rodriguez Rojo, J.; Rodríguez-Frías, M. D.; Ros, G.; Rosado, J.; Rossler, T.; Roth, M.; Rouillé-d'Orfeuil, B.; Roulet, E.; Rovero, A. C.; Rühle, C.; Saffi, S. J.; Saftoiu, A.; Salamida, F.; Salazar, H.; Salesa Greus, F.; Salina, G.; Sánchez, F.; Sanchez-Lucas, P.; Santo, C. E.; Santos, E.; Santos, E. M.; Sarazin, F.; Sarkar, B.; Sarmento, R.; Sato, R.; Scharf, N.; Scherini, V.; Schieler, H.; Schiffer, P.; Schmidt, A.; Scholten, O.; Schoorlemmer, H.; Schovánek, P.; Schröder, F. G.; Schulz, A.; Schulz, J.; Sciutto, S. J.; Scuderi, M.; Segreto, A.; Settimo, M.; Shadkam, A.; Shellard, R. C.; Sidelnik, I.; Sigl, G.; Sima, O.; Śmiałkowski, A.; Šmída, R.; Snow, G. R.; Sommers, P.; Sorokin, J.; Spinka, H.; Squartini, R.; Srivastava, Y. N.; Stanič, S.; Stapleton, J.; Stasielak, J.; Stephan, M.; Straub, M.; Stutz, A.; Suarez, F.; Suomijärvi, T.; Supanitsky, A. D.; Šuša, T.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Szuba, M.; Tapia, A.; Tartare, M.; Taşcǎu, O.; Thao, N. T.; Tiffenberg, J.; Timmermans, C.; Tkaczyk, W.; Todero Peixoto, C. J.; Toma, G.; Tomankova, L.; Tomé, B.; Tonachini, A.; Torralba Elipe, G.; Torres Machado, D.; Travnicek, P.; Tridapalli, D. B.; Trovato, E.; Tueros, M.; Ulrich, R.; Unger, M.; Valdés Galicia, J. F.; Valiño, I.; Valore, L.; van Aar, G.; van den Berg, A. M.; van Velzen, S.; van Vliet, A.; Varela, E.; Vargas Cárdenas, B.; Varner, G.; Vázquez, J. R.; Vázquez, R. A.; Veberič, D.; Verzi, V.; Vicha, J.; Videla, M.; Villaseñor, L.; Wahlberg, H.; Wahrlich, P.; Wainberg, O.; Walz, D.; Watson, A. A.; Weber, M.; Weidenhaupt, K.; Weindl, A.; Werner, F.; Westerhoff, S.; Whelan, B. J.; Widom, A.; Wieczorek, G.; Wiencke, L.; Wilczyńska, B.; Wilczyński, H.; Will, M.; Williams, C.; Winchen, T.; Wundheiler, B.; Wykes, S.; Yamamoto, T.; Yapici, T.; Younk, P.; Yuan, G.; Yushkov, A.; Zamorano, B.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zaw, I.; Zepeda, A.; Zhou, J.; Zhu, Y.; Zimbres Silva, M.; Ziolkowski, M.; Pierre Auger Collaboration

    2014-03-01

    The emission of radio waves from air showers has been attributed to the so-called geomagnetic emission process. At frequencies around 50 MHz this process leads to coherent radiation which can be observed with rather simple setups. The direction of the electric field induced by this emission process depends only on the local magnetic field vector and on the incoming direction of the air shower. We report on measurements of the electric field vector where, in addition to this geomagnetic component, another component has been observed that cannot be described by the geomagnetic emission process. The data provide strong evidence that the other electric field component is polarized radially with respect to the shower axis, in agreement with predictions made by Askaryan who described radio emission from particle showers due to a negative charge excess in the front of the shower. Our results are compared to calculations which include the radiation mechanism induced by this charge-excess process.

  10. Size measurement of plutonium particles from internal sputtering into air

    NASA Astrophysics Data System (ADS)

    Cheng, Yung-Sung; Holmes, Thomas D.; George, Timothy G.; Marlow, William H.

    2005-06-01

    During the past century, the results of spontaneous translocation of radioactivity in air, biological media and groundwater have been reported. Here, we report the first measurements of the size characteristics in air of the particles participating in this translocation phenomenon. For the plutonium material powering radioisotope thermal generators, we find two narrow, well-separated fractions, one corresponding to particles below a nanometer and one at or below 10 nm. These results are interpreted as a gas-phase nucleation phenomenon arising from internal sputtering. They suggest fruitful directions for further research with immediate implications for accounting for the effects of radiological terrorism, for identifying new signatures for nuclear materials of possible use in antiterrorism and other covert nuclear materials operations, for radioactive and mixed materials storage handling, for reactor safety and source term modeling and for other materials processes.

  11. A neural network learned information measures for heart motion abnormality detection

    NASA Astrophysics Data System (ADS)

    Nambakhsh, M. S.; Punithakumar, Kumaradevan; Ben Ayed, Ismail; Goela, Aashish; Islam, Ali; Peters, Terry; Li, Shuo

    2011-03-01

    In this study, we propose an information theoretic neural network for normal/abnormal left ventricular motion classification which outperforms significantly other recent methods in the literature. The proposed framework consists of a supervised 3-layer artificial neural network (ANN) which uses hyperbolic tangent sigmoid and linear transfer functions for hidden and output layers, respectively. The ANN is fed by information theoretic measures of left ventricular wall motion such as Shannon's differential entropy (SDE), Rényi entropy and Fisher information, which measure global information of subjects distribution. Using 395×20 segmented LV cavities of short-axis magnetic resonance images (MRI) acquired from 48 subjects, the experimental results show that the proposed method outperforms Support Vector Machine (SVM) and thresholding based information theoretic classifiers. It yields a specificity equal to 90%, a sensitivity of 91%, and a remarkable Area Under Curve (AUC) for Receiver Operating Characteristic (ROC), equal to 93.2%.

  12. A New Position Measurement System Using a Motion-Capture Camera for Wind Tunnel Tests

    PubMed Central

    Park, Hyo Seon; Kim, Ji Young; Kim, Jin Gi; Choi, Se Woon; Kim, Yousok

    2013-01-01

    Considering the characteristics of wind tunnel tests, a position measurement system that can minimize the effects on the flow of simulated wind must be established. In this study, a motion-capture camera was used to measure the displacement responses of structures in a wind tunnel test, and the applicability of the system was tested. A motion-capture system (MCS) could output 3D coordinates using two-dimensional image coordinates obtained from the camera. Furthermore, this remote sensing system had some flexibility regarding lab installation because of its ability to measure at relatively long distances from the target structures. In this study, we performed wind tunnel tests on a pylon specimen and compared the measured responses of the MCS with the displacements measured with a laser displacement sensor (LDS). The results of the comparison revealed that the time-history displacement measurements from the MCS slightly exceeded those of the LDS. In addition, we confirmed the measuring reliability of the MCS by identifying the dynamic properties (natural frequency, damping ratio, and mode shape) of the test specimen using system identification methods (frequency domain decomposition, FDD). By comparing the mode shape obtained using the aforementioned methods with that obtained using the LDS, we also confirmed that the MCS could construct a more accurate mode shape (bending-deflection mode shape) with the 3D measurements. PMID:24064600

  13. Measurement of motion detection of wireless capsule endoscope inside large intestine.

    PubMed

    Zhou, Mingda; Bao, Guanqun; Pahlavan, Kaveh

    2014-01-01

    Wireless Capsule Endoscope (WCE) provides a noninvasive way to inspect the entire Gastrointestinal (GI) tract, including large intestine, where intestinal diseases most likely occur. As a critical component of capsule endoscopic examination, physicians need to know the precise position of the endoscopic capsule in order to identify the position of detected intestinal diseases. Knowing how the capsule moves inside the large intestine would greatly complement the existing wireless localization systems by providing the motion information. Since the most recently released WCE can take up to 6 frames per second, it's possible to estimate the movement of the capsule by processing the successive image sequence. In this paper, a computer vision based approach without utilizing any external device is proposed to estimate the motion of WCE inside the large intestine. The proposed approach estimate the displacement and rotation of the capsule by calculating entropy and mutual information between frames using Fibonacci method. The obtained results of this approach show its stability and better performance over other existing approaches of motion measurements. Meanwhile, findings of this paper lay a foundation for motion pattern of WCEs inside the large intestine, which will benefit other medical applications. PMID:25571262

  14. Photoinduced Directional Motions of Microparticles at Air-Liquid-Crystal Interfaces of Azobenzene-Doped Liquid-Crystal Films with Homeotropic or Homogeneous Alignment Structures

    NASA Astrophysics Data System (ADS)

    Yamamoto, Takahiro; Yoshida, Masaru

    2012-10-01

    We investigated the effects of liquid-crystal (LC) alignments on photoinduced motions of microparticles at air-LC interfaces of azobenzene-doped LC films. In homeotropically aligned LC films, the lattice spacings of pseudo-hexagonal structures of microparticles site-selectively exhibited reversible expansion or contraction on alternating irradiation with ultraviolet and visible light. The particle motions were probably driven by photochemical deformation of LC surfaces. In homogeneously aligned films, alternating irradiation induced macroscopic convective flows followed by rapid gathering or dispersion of linear chains of microparticles. Particle motions were significantly influenced by LC alignments as well as the light wavelength.

  15. A comparison of lung motion measured using implanted electromagnetic transponders and motion algorithmically predicted using external surrogates as an alternative to respiratory correlated CT imaging

    NASA Astrophysics Data System (ADS)

    Lechleiter, Kristen M.; Low, Daniel A.; Chaudhari, Amir; Lu, Wei; Hubenschmidt, James P.; Mayse, Martin L.; Dimmer, Steven C.; Bradley, Jeffrey D.; Parikh, Parag J.

    2007-03-01

    Three-dimensional volumetric imaging correlated with respiration (4DCT) typically utilizes external breathing surrogates and phase-based models to determine lung tissue motion. However, 4DCT requires time consuming post-processing and the relationship between external breathing surrogates and lung tissue motion is not clearly defined. This study compares algorithms using external respiratory motion surrogates as predictors of internal lung motion tracked in real-time by electromagnetic transponders (Calypso® Medical Technologies) implanted in a canine model. Simultaneous spirometry, bellows, and transponder positions measurements were acquired during free breathing and variable ventilation respiratory patterns. Functions of phase, amplitude, tidal volume, and airflow were examined by least-squares regression analysis to determine which algorithm provided the best estimate of internal motion. The cosine phase model performed the worst of all models analyzed (R2 = 31.6%, free breathing, and R2 = 14.9%, variable ventilation). All algorithms performed better during free breathing than during variable ventilation measurements. The 5D model of tidal volume and airflow predicted transponder location better than amplitude or either of the two phasebased models analyzed, with correlation coefficients of 66.1% and 64.4% for free breathing and variable ventilation respectively. Real-time implanted transponder based measurements provide a direct method for determining lung tissue location. Current phase-based or amplitude-based respiratory motion algorithms cannot as accurately predict lung tissue motion in an irregularly breathing subject as a model including tidal volume and airflow. Further work is necessary to quantify the long term stability of prediction capabilities using amplitude and phase based algorithms for multiple lung tumor positions over time.

  16. Pressure measurements of a three wave journal air bearing

    NASA Technical Reports Server (NTRS)

    Dimofte, Florin; Addy, Harold E., Jr.

    1994-01-01

    In order to validate theoretical predictions of a wave journal bearing concept, a bench test rig was assembled at NASA Lewis Research Center to measure the steady-state performance of a journal air bearing. The tester can run up to 30,000 RPM and the spindle has a run out of less than 1 micron. A three wave journal bearing (50 mm diameter and 58 mm length) has been machined at NASA Lewis. The pressures at 16 ports along the bearing circumference at the middle of the bearing length were measured and compared to the theoretical prediction. The bearing ran at speeds up to 15,000 RPM and certain loads. Good agreement was found between the measured and calculated pressures.

  17. Air-Sea Interaction Measurements from R/P FLIP

    NASA Astrophysics Data System (ADS)

    Friehe, C. A.

    2002-12-01

    Soon after its inception, R/P FLIP was used to study the interaction of the atmosphere and ocean due to its unique stability and low flow distortion. A number of campaigns have been conducted to measure the surface fluxes of heat, water vapor and horizontal momentum of the wind with instrumentation as used over land, supported by the Office of Naval Research and the National Science Foundation. The size of FLIP allows for simultaneous ocean wave and mixed-layer measurements as well. Air-sea interaction was a prime component of BOMEX in 1968, where FLIP transited the Panama Canal. The methods used were similar to the over-land "Kansas" experiment of AFCRL in 1968. BOMEX was followed by many experiments in the north Pacific off San Diego, northern California, and Hawaii. Diverse results from FLIP include identification of the mechanism that causes erroneous fluctuating temperature measurements in the salt-aerosol-laden marine atmosphere, the role of humidity on optical refractive index fluctuations, and identification of Miles' critical layer in the air flow over waves.

  18. Empowering smartphone users with sensor node for air quality measurement

    NASA Astrophysics Data System (ADS)

    Oletic, Dinko; Bilas, Vedran

    2013-06-01

    We present an architecture of a sensor node developed for use with smartphones for participatory sensing of air quality in urban environments. Our solution features inexpensive metal-oxide semiconductor gas sensors (MOX) for measurement of CO, O3, NO2 and VOC, along with sensors for ambient temperature and humidity. We focus on our design of sensor interface consisting of power-regulated heater temperature control, and the design of resistance sensing circuit. Accuracy of the sensor interface is characterized. Power consumption of the sensor node is analysed. Preliminary data obtained from the CO gas sensors in laboratory conditions and during the outdoor field-test is shown.

  19. Autocorrelation spectra of an air-fluidized granular system measured by NMR

    NASA Astrophysics Data System (ADS)

    Lasic, S.; Stepisnik, J.; Mohoric, A.; Sersa, I.; Planinsic, G.

    2006-09-01

    A novel insight into the dynamics of a fluidized granular system is given by a nuclear magnetic resonance method that yields the spin-echo attenuation proportional to the spectrum of the grain positional fluctuation. Measurements of the air-fluidized oil-filled spheres and mustard seeds at different degrees of fluidization and grain volume fractions provide the velocity autocorrelation that differs from the commonly anticipated exponential Enskog decay. An empiric formula, which corresponds to the model of grain caging at collisions with adjacent beads, fits well to the experimental data. Its parameters are the characteristic collision time, the free path between collisions and the cage-breaking rate or the diffusion-like constant, which decreases with increasing grain volume fraction. Mean-squared displacements calculated from the correlation spectrum clearly show transitions from ballistic, through sub-diffusion and into diffusion regimes of grain motion.

  20. The impact of European measures to reduce air pollutants on air quality, human health and climate

    NASA Astrophysics Data System (ADS)

    Turnock, S.; Butt, E. W.; Richardson, T.; Mann, G.; Forster, P.; Haywood, J. M.; Crippa, M.; Janssens-Maenhout, G. G. A.; Johnson, C.; Bellouin, N.; Spracklen, D. V.; Carslaw, K. S.; Reddington, C.

    2015-12-01

    European air quality legislation has reduced emissions of air pollutants across Europe since the 1970s, resulting in improved air quality and benefits to human health but also an unintended impact on regional climate. Here we used a coupled chemistry-climate model and a new policy relevant emission scenario to determine the impact of air pollutant emission reductions over Europe. The emission scenario shows that a combination of technological improvements and end-of-pipe abatement measures in the energy, industrial and road transport sectors reduced European emissions of sulphur dioxide, black carbon and organic carbon by 53%, 59% and 32% respectively. We estimate that these emission reductions decreased European annual mean concentrations of fine particulate matter (PM2.5) by 35%, sulphate by 44%, black carbon (BC) by 56% and particulate organic matter (POM) by 23%. The reduction in PM2.5 concentrations is calculated to have prevented 107,000 (40,000-172,000, 5-95% confidence intervals) premature deaths annually from cardiopulmonary disease and lung cancer across the EU member states. The decrease in aerosol concentrations caused a positive all-sky aerosol radiative forcing at the top of atmosphere over Europe of 2.3±0.06 W m-2 and a positive clear-sky forcing of 1.7±0.05 W m-2. Additionally, the amount of solar radiation incident at the surface over Europe increased by 3.3±0.07 W m-2 under all-sky and by 2.7±0.05 W m-2 under clear-sky conditions. Reductions in BC concentrations caused a 1 Wm-2 reduction in atmospheric absorption. We use an energy budget approximation to show that the aerosol induced radiative changes caused both temperature and precipitation to increase globally and over Europe. Our results show that the implementation of European legislation to reduce the emission of air pollutants has improved air quality and human health over Europe, as well as altered the regional radiative balance and climate.

  1. Gage cookbook: Tools and techniques to measure stresses and motions on explosive experiments

    SciTech Connect

    Smith, C.W.

    1996-01-01

    Tools and techniques developed to measure stresses and motions on underground nuclear and high explosive tests in the tuff geologies at the Nevada Test Site are described in this document. The thrust of the measurements was to understand containment phenomenology. The authors concentrate on the fluid-coupled ytterbium gage; it was fielded to measure dynamic stress in the 0.2 to 20 kilobar range and the subsequent, low amplitude residual stress. Also described are accelerometer packages; their traces were integrated to obtain particle motion. Various cable survival techniques were investigated with field measurements for they wished to extend the measurements to late-time. Field measurements were also made to address the gage inclusion problem. Work to date suggests that the problem is a minimum when the stress level is above the yield strength of the host rock and grout. Below the yield level stress amplitudes in the grouted hole can range from 60 to 200% of the stress in the host rock.

  2. Performance Evaluation of Smartphone Inertial Sensors Measurement for Range of Motion.

    PubMed

    Mourcou, Quentin; Fleury, Anthony; Franco, Céline; Klopcic, Frédéric; Vuillerme, Nicolas

    2015-01-01

    Over the years, smartphones have become tools for scientific and clinical research. They can, for instance, be used to assess range of motion and joint angle measurement. In this paper, our aim was to determine if smartphones are reliable and accurate enough for clinical motion research. This work proposes an evaluation of different smartphone sensors performance and different manufacturer algorithm performances with the comparison to the gold standard, an industrial robotic arm with an actual standard use inertial motion unit in clinical measurement, an Xsens product. Both dynamic and static protocols were used to perform these comparisons. Root Mean Square (RMS) mean values results for static protocol are under 0.3° for the different smartphones. RMS mean values results for dynamic protocol are more prone to bias induced by Euler angle representation. Statistical results prove that there are no filter effect on results for both protocols and no hardware effect. Smartphones performance can be compared to the Xsens gold standard for clinical research. PMID:26389900

  3. Performance Evaluation of Smartphone Inertial Sensors Measurement for Range of Motion

    PubMed Central

    Mourcou, Quentin; Fleury, Anthony; Franco, Céline; Klopcic, Frédéric; Vuillerme, Nicolas

    2015-01-01

    Over the years, smartphones have become tools for scientific and clinical research. They can, for instance, be used to assess range of motion and joint angle measurement. In this paper, our aim was to determine if smartphones are reliable and accurate enough for clinical motion research. This work proposes an evaluation of different smartphone sensors performance and different manufacturer algorithm performances with the comparison to the gold standard, an industrial robotic arm with an actual standard use inertial motion unit in clinical measurement, an Xsens product. Both dynamic and static protocols were used to perform these comparisons. Root Mean Square (RMS) mean values results for static protocol are under 0.3° for the different smartphones. RMS mean values results for dynamic protocol are more prone to bias induced by Euler angle representation. Statistical results prove that there are no filter effect on results for both protocols and no hardware effect. Smartphones performance can be compared to the Xsens gold standard for clinical research. PMID:26389900

  4. Two modes of motion of the alligator lizard cochlea: Measurements and model predictions

    NASA Astrophysics Data System (ADS)

    Aranyosi, A. J.; Freeman, Dennis M.

    2005-09-01

    Measurements of motion of an in vitro preparation of the alligator lizard basilar papilla in response to sound demonstrate elliptical trajectories. These trajectories are consistent with the presence of both a translational and rotational mode of motion. The translational mode is independent of frequency, and the rotational mode has a displacement peak near 5 kHz. These measurements can be explained by a simple mechanical system in which the basilar papilla is supported asymmetrically on the basilar membrane. In a quantitative model, the translational admittance is compliant while the rotational admittance is second order. Best-fit model parameters are consistent with estimates based on anatomy and predict that fluid flow across hair bundles is a primary source of viscous damping. The model predicts that the rotational mode contributes to the high-frequency slopes of auditory nerve fiber tuning curves, providing a physical explanation for a low-pass filter required in models of this cochlea. The combination of modes makes the sensitivity of hair bundles more uniform with radial position than that which would result from pure rotation. A mechanical analogy with the organ of Corti suggests that these two modes of motion may also be present in the mammalian cochlea.

  5. [Measurement of the knee range of motion: standard goniometer or smartphone?].

    PubMed

    Rwakabayiza, Sylvia; Pereira, Luis Carlos; Lécureux, Estelle; Jolles-Haeberli, Brigitte

    2013-12-18

    Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice. PMID:24693586

  6. Correction of motion measurement errors beyond the range resolution of a synthetic aperture radar

    DOEpatents

    Doerry, Armin W.; Heard, Freddie E.; Cordaro, J. Thomas

    2008-06-24

    Motion measurement errors that extend beyond the range resolution of a synthetic aperture radar (SAR) can be corrected by effectively decreasing the range resolution of the SAR in order to permit measurement of the error. Range profiles can be compared across the slow-time dimension of the input data in order to estimate the error. Once the error has been determined, appropriate frequency and phase correction can be applied to the uncompressed input data, after which range and azimuth compression can be performed to produce a desired SAR image.

  7. [Measurement of the knee range of motion: standard goniometer or smartphone?].

    PubMed

    Rwakabayiza, Sylvia; Pereira, Luis Carlos; Lécureux, Estelle; Jolles-Haeberli, Brigitte

    2013-12-18

    Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.

  8. Investigation on Plasma Jet Flow Phenomena During DC Air Arc Motion in Bridge-Type Contacts

    NASA Astrophysics Data System (ADS)

    Zhai, Guofu; Bo, Kai; Chen, Mo; Zhou, Xue; Qiao, Xinlei

    2016-05-01

    Arc plasma jet flow in the air was investigated under a bridge-type contacts in a DC 270 V resistive circuit. We characterized the arc plasma jet flow appearance at different currents by using high-speed photography, and two polished contacts were used to search for the relationship between roughness and plasma jet flow. Then, to make the nature of arc plasma jet flow phenomena clear, a simplified model based on magnetohydrodynamic (MHD) theory was established and calculated. The simulated DC arc plasma was presented with the temperature distribution and the current density distribution. Furthermore, the calculated arc flow velocity field showed that the circular vortex was an embodiment of the arc plasma jet flow progress. The combined action of volume force and contact surface was the main reason of the arc jet flow. supported by National Natural Science Foundation of China (Nos. 51307030, 51277038)

  9. The influence of bowl offset on air motion in a direct injection diesel engine

    SciTech Connect

    McKinley, T.L.; Primus, R.J

    1988-01-01

    The influence of bowl offset on motored mean flow and turbulence in a direct injection diesel engine has been examined with the aid of a multi-dimensional flow code. Results are presented for three piston geometries. The bowl geometry of each piston was the same, while the offset between the bowl and the cylinder axis was varied from 0.0 to 9.6% of the bore. The swirl ratio at intake valve closing was also varied from 2.60 to 4.27. It was found that the angular momentum of the air at TDC was decreased by less than 8% when the bowl was offset. Nevertheless, the mean (squish and swirl) flows were strongly affected by the offset. In addition, the distribution of turbulent kinetic energy (predicted by the /delta/-e model) was modified. Moderate increases (10% or less) in mass averaged turbulence intensity at TDC with offset were observed.

  10. Radar Echo Structure, Air Motion and Hail Formation in a Large Stationary Multicellular Thunderstorm.

    NASA Astrophysics Data System (ADS)

    Miller, L. J.; Fankhauser, J. C.

    1983-10-01

    Observations from aircraft, Doppler radars, surface mesonetwork, upper air network and surveillance radar are used to describe the structure and evolution of a large rain and hailstorm that occurred on 22 June 1976 in northeastern Colorado. In its early stage, the storm was unicellular in nature and was moving northward somewhat slower than the middle-level environmental winds. Once significant outflow developed beneath the storm, new cells started their growth over the southeastwardly progressing outflow boundary and then advected northward and interacted with the now nearly motionless main updraft. For about 45 min the storm exhibited characteristics of the steady, vaulted supercell, though overall it was still clearly multicellular in nature. During this stage nearly 2.5×109 kg s1 of air and 2×107 kg s1 of moisture were being processed through cloud base within the vault updraft. Precipitation that grew to millimeter size within the small (about 5 km diameter) cells served as embryos for continued growth to hailstones as big as 3 cm diameter within the main updraft associated with the weak echo vault. Calculated ice particle growth trajectories in the nearly steady phase indicated that recycling of precipitation particles within a single updraft was not possible, however, as all particles followed simple paths northward across and to the sides of the main updraft core, failing out as rain, graupel or hail on the north and west sides of the updraft. Small particles that entered the main updraft where speeds exceeded 15 m s1 were exhausted into the anvil as 5-8 mm graupel.

  11. Climatology of Vertical Air Motion During Rainfall in Niamey, Niger and Black Forest, Germany using an Innovative Cloud Radar Retrieval Technique

    NASA Astrophysics Data System (ADS)

    Luke, E. P.; Giangrande, S. E.; Kollias, P.

    2008-12-01

    In recent years, the DOE Atmospheric Radiation Measurement (ARM) program has deployed its ARM Mobile Facility (AMF) to collect continuous measurements in several climatologically distinct locations, including a year-long stay in Niamey, Niger and eight months in Germany's Black Forest. The AMF includes a vertically pointing 95 GHz cloud radar, a tool of choice for profiling non-precipitating clouds at high spatial and temporal resolutions, but commonly considered poorly suited to the quantitative study of precipitation, due in large part to attenuation. However, an innovative technique first explored by Lhermitte in the late 1980s, and subsequently by others, sidesteps much of the quantitative uncertainty imposed by attenuation by exploiting non-Rayleigh resonance effects of scattering from raindrops at 95 GHz. Given a modest range of suitable drop sizes, non-Rayleigh resonances appear as distinct peaks and valleys in Doppler spectra, which once identified, can be directly mapped to known drop sizes by Mie theory. Although attenuation in rain at 95 GHz is substantial, key to the technique is that all non-Rayleigh peaks and valleys in a given Doppler spectrum are affected equally, preserving their relative positions and magnitudes (barring feature extinction). Vertical air motion is retrieved very accurately by taking the difference between the measured Doppler velocity of a resonance feature (usually the first valley) and the known terminal velocity of its associated drop size. We have achieved promising retrieval accuracies at spatial and temporal resolutions of 30 meters and 2 seconds. Here we present lessons learned when the retrieval technique is automated and applied to measurements taken in rain over the full durations of the Niamey and Black Forest AMF deployments, comparing vertical air velocity patterns of monsoonal precipitation over the African desert with those of the orographically influenced precipitation in Germany's mountains.

  12. Air toxics being measured more accurately, controlled more effectively

    SciTech Connect

    1995-04-01

    In response to the directives of the Clean Air Act Amendments, Argonne National Laboratory is developing new or improved pollutant control technologies for industries that burn fossil fuels. This research continues Argonne`s traditional support for the US DOE Flue Gas Cleanup Program. Research is underway to measure process emissions and identify new and improved control measures. Argonne`s emission control research has ranged from experiments in the basic chemistry of pollution-control systems, through laboratory-scale process development and testing to pilot-scale field tests of several technologies. Whenever appropriate, the work has emphasized integrated or combined control systems as the best approach to technologies that offer low cost and good operating characteristics.

  13. Projection Moire Interferometry Measurements of Micro Air Vehicle Wings

    NASA Technical Reports Server (NTRS)

    Fleming, Gary A.; Bartram, Scott M.; Waszak, Martin R.; Jenkins, Luther N.

    2001-01-01

    Projection Moire Interferometry (PMI) has been used to measure the structural deformation of micro air vehicle (MAV) wings during a series of wind tunnel tests. The MAV wings had a highly flexible wing structure, generically reminiscent of a bat s wing, which resulted in significant changes in wing shape as a function of MAV angle-of-attack and simulated flight speed. This flow-adaptable wing deformation is thought to provide enhanced vehicle stability and wind gust alleviation compared to rigid wing designs. Investigation of the potential aerodynamic benefits of a flexible MAV wing required measurement of the wing shape under aerodynamic loads. PMI was used to quantify the aerodynamically induced changes in wing shape for three MAV wings having different structural designs and stiffness characteristics. This paper describes the PMI technique, its application to MAV testing, and presents a portion of the PMI data acquired for the three different MAV wings tested.

  14. Inertial sensors as measurement tools of elbow range of motion in gerontology

    PubMed Central

    Sacco, G; Turpin, JM; Marteu, A; Sakarovitch, C; Teboul, B; Boscher, L; Brocker, P; Robert, P; Guerin, O

    2015-01-01

    Background and purpose Musculoskeletal system deterioration among the aging is a major reason for loss of autonomy and directly affects the quality of life of the elderly. Articular evaluation is part of physiotherapeutic assessment and helps in establishing a precise diagnosis and deciding appropriate therapy. Reference instruments are valid but not easy to use for some joints. The main goal of our study was to determine reliability and intertester reproducibility of the MP-BV, an inertial sensor (the MotionPod® [MP]) combined with specific software (BioVal [BV]), for elbow passive range-of-motion measurements in geriatrics. Methods This open, monocentric, randomized study compared inertial sensor to inclinometer in patients hospitalized in an acute, post-acute, and long-term-care gerontology unit. Results Seventy-seven patients (mean age 83.5±6.4 years, sex ratio 1.08 [male/female]) were analyzed. The MP-BV was reliable for each of the three measurements (flexion, pronation, and supination) for 24.3% (CI 95% 13.9–32.8) of the patients. Separately, the percentages of reliable measures were 59.7% (49.2–70.5) for flexion, 68.8% (58.4–79.5) for pronation, and 62.3% (51.2–73.1) for supination. The intraclass correlation coefficients were 0.15 (0.07–0.73), 0.46 (0.27–0.98), and 0.50 (0.31–40 0.98) for flexion, pronation, and supination, respectively. Conclusion This study shows the convenience of the MP-BV in terms of ease of use and of export of measured data. However, this instrument seems less reliable and valuable compared to the reference instruments used to measure elbow range of motion in gerontology. PMID:25759568

  15. Measurement of Intervertebral Cervical Motion by Means of Dynamic X-Ray Image Processing and Data Interpolation

    PubMed Central

    Bifulco, Paolo; Cesarelli, Mario; Romano, Maria; Sansone, Mario

    2013-01-01

    Accurate measurement of intervertebral kinematics of the cervical spine can support the diagnosis of widespread diseases related to neck pain, such as chronic whiplash dysfunction, arthritis, and segmental degeneration. The natural inaccessibility of the spine, its complex anatomy, and the small range of motion only permit concise measurement in vivo. Low dose X-ray fluoroscopy allows time-continuous screening of cervical spine during patient's spontaneous motion. To obtain accurate motion measurements, each vertebra was tracked by means of image processing along a sequence of radiographic images. To obtain a time-continuous representation of motion and to reduce noise in the experimental data, smoothing spline interpolation was used. Estimation of intervertebral motion for cervical segments was obtained by processing patient's fluoroscopic sequence; intervertebral angle and displacement and the instantaneous centre of rotation were computed. The RMS value of fitting errors resulted in about 0.2 degree for rotation and 0.2 mm for displacements. PMID:24288523

  16. Gas and liquid measurements in air-water bubbly flows

    SciTech Connect

    Zhou, X.; Doup, B.; Sun, X.

    2012-07-01

    Local measurements of gas- and liquid-phase flow parameters are conducted in an air-water two-phase flow loop. The test section is a vertical pipe with an inner diameter of 50 mm and a height of 3.2 m. The measurements are performed at z/D = 10. The gas-phase measurements are performed using a four-sensor conductivity probe. The data taken from this probe are processed using a signal processing program to yield radial profiles of the void fraction, bubble velocity, and interfacial area concentration. The velocity measurements of the liquid-phase are performed using a state-of-the-art Particle Image Velocimetry (PIV) system. The raw PIV images are acquired using fluorescent particles and an optical filtration device. Image processing is used to remove noise in the raw PIV images. The statistical cross correlation is introduced to determine the axial velocity field and turbulence intensity of the liquid-phase. Measurements are currently being performed at z/D = 32 to provide a more complete data set. These data can be used for computational fluid dynamic model development and validation. (authors)

  17. Free-breathing respiratory motion of the heart measured from x-ray coronary angiograms (Second Place Student Paper Award)

    NASA Astrophysics Data System (ADS)

    Shechter, Guy; Ozturk, Cengizhan; Resar, Jon R.; McVeigh, Elliot R.

    2004-04-01

    Respiratory motion compensation for cardiac imaging requires knowledge of the heart's motion and deformation during breathing. We propose a method for measuring the natural tidal respiratory motion of the heart using free breathing coronary angiograms. A 3D deformation field describing the cardiac and respiratory motion of the coronary arteries is recovered from a biplane acquisition. Cardiac and respiratory phase are assigned to the images from an ECG signal synchronized to the image acquisition, and from the diaphragmatic displacement as observed in the images. The resulting motion field is decomposed into cardiac and respiratory components by fitting the field with periodic 2D parametric functions, where one dimension spans one cardiac cycle, and the second dimension spans one respiratory cycle. The method is applied to patient datasets, and an analysis of respiratory motion of the heart is presented.

  18. Mobile Air Monitoring: Measuring Change in Air Quality in the City of Hamilton, 2005-2010

    ERIC Educational Resources Information Center

    Adams, Matthew D.; DeLuca, Patrick F.; Corr, Denis; Kanaroglou, Pavlos S.

    2012-01-01

    This paper examines the change in air pollutant concentrations between 2005 and 2010 occurring in the City of Hamilton, Ontario, Canada. After analysis of stationary air pollutant concentration data, we analyze mobile air pollutant concentration data. Air pollutants included in the analysis are CO, PM[subscript 2.5], SO[subscript 2], NO,…

  19. Measuring Sea-Ice Motion in the Arctic with Real Time Photogrammetry

    NASA Astrophysics Data System (ADS)

    Brozena, J. M.; Hagen, R. A.; Peters, M. F.; Liang, R.; Ball, D.

    2014-12-01

    The U.S. Naval Research Laboratory, in coordination with other groups, has been collecting sea-ice data in the Arctic off the north coast of Alaska with an airborne system employing a radar altimeter, LiDAR and a photogrammetric camera in an effort to obtain wide swaths of measurements coincident with Cryosat-2 footprints. Because the satellite tracks traverse areas of moving pack ice, precise real-time estimates of the ice motion are needed to fly a survey grid that will yield complete data coverage. This requirement led us to develop a method to find the ice motion from the aircraft during the survey. With the advent of real-time orthographic photogrammetric systems, we developed a system that measures the sea ice motion in-flight, and also permits post-process modeling of sea ice velocities to correct the positioning of radar and LiDAR data. For the 2013 and 2014 field seasons, we used this Real Time Ice Motion Estimation (RTIME) system to determine ice motion using Applanix's Inflight Ortho software with an Applanix DSS439 system. Operationally, a series of photos were taken in the survey area. The aircraft then turned around and took more photos along the same line several minutes later. Orthophotos were generated within minutes of collection and evaluated by custom software to find photo footprints and potential overlap. Overlapping photos were passed to the correlation software, which selects a series of "chips" in the first photo and looks for the best matches in the second photo. The correlation results are then passed to a density-based clustering algorithm to determine the offset of the photo pair. To investigate any systematic errors in the photogrammetry, we flew several flight lines over a fixed point on various headings, over an area of non-moving ice in 2013. The orthophotos were run through the correlation software to find any residual offsets, and run through additional software to measure chip positions and offsets relative to the aircraft

  20. Acoustic levitator for contactless motion and merging of large droplets in air

    NASA Astrophysics Data System (ADS)

    Bjelobrk, Nada; Nabavi, Majid; Poulikakos, Dimos

    2012-09-01

    Large droplet transport in a line-focussed acoustic manipulator in terms of maximum droplet size is achieved by employing a driving voltage control mechanism. The maximum volume of the transported droplets in the order of few microliters is thereby increased by three orders of magnitude compared to the constant voltage case, widening the application field of this method significantly. A drop-on-demand droplet generator is used to supply the liquid droplets into the system. The ejected sequence of picoliter-size droplets is guided along trajectories by the acoustic field and accumulates at the selected pressure node, merging into a single large droplet. Droplet movement is achieved by varying the reflector height. This also changes the intensity of the radiation pressure during droplet movement, which in turn could atomise the droplet. The acoustic force is adjusted by regulating the driving voltage of the actuator to keep the liquid droplet suspended in air and to prevent atomisation. In the herein presented levitation concept, liquids with a wide range of surface tension (water and tetradecane were tested) can be transported over distances of several mm. The aspect ratio of the droplet in the acoustic field is shown to be a good indicator for radiation pressure intensity and is kept between 1.1 and 1.4 during droplet transport. Despite certain limitations with volatile liquids, the presented acoustic levitator concept has the potential to expand the range of analytical characterisation and manipulation methods in applications ranging from chemistry and biology.

  1. Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System

    PubMed Central

    2016-01-01

    Objective To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). Methods Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland–Altman plot with 95% limits of agreement (LoA). Results MoCap and ARHS showed fair agreement (95% LoA<10°), while MoCap and Kinect showed less favorable agreement (95% LoA>10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in –40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in –40° to 40° range were fair for all motions. Conclusion Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range. PMID:27606262

  2. Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System

    PubMed Central

    2016-01-01

    Objective To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). Methods Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland–Altman plot with 95% limits of agreement (LoA). Results MoCap and ARHS showed fair agreement (95% LoA<10°), while MoCap and Kinect showed less favorable agreement (95% LoA>10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in –40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in –40° to 40° range were fair for all motions. Conclusion Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range.

  3. Vesicle Motion during Sustained Exocytosis in Chromaffin Cells: Numerical Model Based on Amperometric Measurements.

    PubMed

    Jarukanont, Daungruthai; Bonifas Arredondo, Imelda; Femat, Ricardo; Garcia, Martin E

    2015-01-01

    Chromaffin cells release catecholamines by exocytosis, a process that includes vesicle docking, priming and fusion. Although all these steps have been intensively studied, some aspects of their mechanisms, particularly those regarding vesicle transport to the active sites situated at the membrane, are still unclear. In this work, we show that it is possible to extract information on vesicle motion in Chromaffin cells from the combination of Langevin simulations and amperometric measurements. We developed a numerical model based on Langevin simulations of vesicle motion towards the cell membrane and on the statistical analysis of vesicle arrival times. We also performed amperometric experiments in bovine-adrenal Chromaffin cells under Ba2+ stimulation to capture neurotransmitter releases during sustained exocytosis. In the sustained phase, each amperometric peak can be related to a single release from a new vesicle arriving at the active site. The amperometric signal can then be mapped into a spike-series of release events. We normalized the spike-series resulting from the current peaks using a time-rescaling transformation, thus making signals coming from different cells comparable. We discuss why the obtained spike-series may contain information about the motion of all vesicles leading to release of catecholamines. We show that the release statistics in our experiments considerably deviate from Poisson processes. Moreover, the interspike-time probability is reasonably well described by two-parameter gamma distributions. In order to interpret this result we computed the vesicles' arrival statistics from our Langevin simulations. As expected, assuming purely diffusive vesicle motion we obtain Poisson statistics. However, if we assume that all vesicles are guided toward the membrane by an attractive harmonic potential, simulations also lead to gamma distributions of the interspike-time probability, in remarkably good agreement with experiment. We also show that

  4. Vesicle Motion during Sustained Exocytosis in Chromaffin Cells: Numerical Model Based on Amperometric Measurements.

    PubMed

    Jarukanont, Daungruthai; Bonifas Arredondo, Imelda; Femat, Ricardo; Garcia, Martin E

    2015-01-01

    Chromaffin cells release catecholamines by exocytosis, a process that includes vesicle docking, priming and fusion. Although all these steps have been intensively studied, some aspects of their mechanisms, particularly those regarding vesicle transport to the active sites situated at the membrane, are still unclear. In this work, we show that it is possible to extract information on vesicle motion in Chromaffin cells from the combination of Langevin simulations and amperometric measurements. We developed a numerical model based on Langevin simulations of vesicle motion towards the cell membrane and on the statistical analysis of vesicle arrival times. We also performed amperometric experiments in bovine-adrenal Chromaffin cells under Ba2+ stimulation to capture neurotransmitter releases during sustained exocytosis. In the sustained phase, each amperometric peak can be related to a single release from a new vesicle arriving at the active site. The amperometric signal can then be mapped into a spike-series of release events. We normalized the spike-series resulting from the current peaks using a time-rescaling transformation, thus making signals coming from different cells comparable. We discuss why the obtained spike-series may contain information about the motion of all vesicles leading to release of catecholamines. We show that the release statistics in our experiments considerably deviate from Poisson processes. Moreover, the interspike-time probability is reasonably well described by two-parameter gamma distributions. In order to interpret this result we computed the vesicles' arrival statistics from our Langevin simulations. As expected, assuming purely diffusive vesicle motion we obtain Poisson statistics. However, if we assume that all vesicles are guided toward the membrane by an attractive harmonic potential, simulations also lead to gamma distributions of the interspike-time probability, in remarkably good agreement with experiment. We also show that

  5. Vesicle Motion during Sustained Exocytosis in Chromaffin Cells: Numerical Model Based on Amperometric Measurements

    PubMed Central

    Jarukanont, Daungruthai; Bonifas Arredondo, Imelda; Femat, Ricardo; Garcia, Martin E.

    2015-01-01

    Chromaffin cells release catecholamines by exocytosis, a process that includes vesicle docking, priming and fusion. Although all these steps have been intensively studied, some aspects of their mechanisms, particularly those regarding vesicle transport to the active sites situated at the membrane, are still unclear. In this work, we show that it is possible to extract information on vesicle motion in Chromaffin cells from the combination of Langevin simulations and amperometric measurements. We developed a numerical model based on Langevin simulations of vesicle motion towards the cell membrane and on the statistical analysis of vesicle arrival times. We also performed amperometric experiments in bovine-adrenal Chromaffin cells under Ba2+ stimulation to capture neurotransmitter releases during sustained exocytosis. In the sustained phase, each amperometric peak can be related to a single release from a new vesicle arriving at the active site. The amperometric signal can then be mapped into a spike-series of release events. We normalized the spike-series resulting from the current peaks using a time-rescaling transformation, thus making signals coming from different cells comparable. We discuss why the obtained spike-series may contain information about the motion of all vesicles leading to release of catecholamines. We show that the release statistics in our experiments considerably deviate from Poisson processes. Moreover, the interspike-time probability is reasonably well described by two-parameter gamma distributions. In order to interpret this result we computed the vesicles’ arrival statistics from our Langevin simulations. As expected, assuming purely diffusive vesicle motion we obtain Poisson statistics. However, if we assume that all vesicles are guided toward the membrane by an attractive harmonic potential, simulations also lead to gamma distributions of the interspike-time probability, in remarkably good agreement with experiment. We also show that

  6. Measurement of indoor air quality in two new test houses

    SciTech Connect

    Hodgson, A.T.

    1996-01-01

    This study assessed indoor air quality in two similar, new houses being evaluated for energy performance. One house (A) was built conventionally. The other (B) was an energy-efficient structure. Air samples for individual volatile organic compounds (VOCs), total VOCs (TVOC) and formaldehyde were collected following completion of the interiors of the houses and on several occasions during the following year. Ventilation rates were also determined so that source strengths of airborne contaminants could be estimated with a mass- balance model. There were no substantial differences in indoor air quality between the houses. The TVOC concentrations in House A ranged from 1,700 - 4,400 {mu}p m{sup -3}, with the highest value coinciding with the lowest ventilation rate. The TVOC concentrations in House B were 2,400 - 2,800 {mu}g m{sup -3}. These values are elevated compared to a median value of 700 {mu}g m{sup -3} measured for a large residential study. Formaldehyde concentrations ranged up to 74 {mu}g m{sup -3}. The dominant VOC in both houses was hexanal, an odorous chemical irritant. The concentrations of acetone, pentanal, toluene, alpha-pinene and other aldehydes were also relatively high in both houses. The source strengths of many of the analytes did not decline substantially over the course of the study. The OSB was estimated to contribute substantially to concentrations of formaldehyde and acetone in the houses. The results also suggested that OSB was not the dominant source of pentanal, hexanal and alpha-pinene, all of which had elevated emissions in the houses, possibly from a single source.

  7. Thickness and air gap measurement of assembled IR objectives

    NASA Astrophysics Data System (ADS)

    Lueerss, B.; Langehanenberg, P.

    2015-05-01

    A growing number of applications like surveillance, thermography, or automotive demand for infrared imaging systems. Their imaging performance is significantly influenced by the alignment of the individual lens elements. Besides the lateral orientation of lenses, the air spacing between the lenses is a crucial parameter. Because of restricted mechanical accessibility within an assembled objective, a non-contact technique is required for the testing of these parameters. So far commercial measurement systems were not available for testing of IR objectives since many materials used for infrared imaging are non-transparent at wavelengths below 2 μm. We herewith present a time-domain low coherent interferometer capable of measuring any kind of infrared material (e.g., Ge, Si, etc.) as well as VIS materials. The fiber-optic set-up is based on a Michelson-Interferometer in which the light from a broadband super-luminescent diode is split into a reference arm with a variable optical delay and a measurement arm where the sample is placed. On a photo detector, the reflected signals from both arms are superimposed and recorded as a function of the variable optical path. Whenever the group delay difference is zero, a coherence peak occurs and the relative lens' surface distances are derived from the optical delay. In order to penetrate IR materials, the instrument operates at 2.2 μm. The set-up allows the contactless determination of thicknesses and air gaps inside of assembled infrared objective lenses with accuracy in the micron range. It therefore is a tool for the precise manufacturing or quality control.

  8. Thickness and air gap measurement of assembled IR objectives

    NASA Astrophysics Data System (ADS)

    Lueerss, B.; Langehanenberg, P.

    2015-10-01

    A growing number of applications like surveillance, thermography, or automotive demand for infrared imaging systems. Their imaging performance is significantly influenced by the alignment of the individual lenses. Besides the lateral orientation of lenses, the air spacing between the lenses is a crucial parameter. Because of restricted mechanical accessibility within an assembled objective, a non-contact technique is required for the testing of these parameters. So far, commercial measurement systems were not available for testing of IR objectives since most materials used for infrared imaging are non-transparent at wavelengths below 2 μm. We herewith present a time-domain low coherent interferometer capable of measuring any kind of infrared material (e.g., Ge, Si, etc.) as well as VIS materials. The set-up is based on a Michelson interferometer in which the light from a broadband superluminescent diode is split into a reference arm with a variable optical delay and a measurement arm where the sample is placed. On a detector, the reflected signals from both arms are superimposed and recorded as a function of the variable optical path. Whenever the group delay difference is zero, a coherence peak occurs and the relative distances of the lens surfaces are derived from the optical delay. In order to penetrate IR materials, the instrument operates at 2.2 μm. Together with an LWIR autocollimator, this technique allows for the determination of centering errors, lens thicknesses and air spacings of assembled IR objective lenses with a micron accuracy. It is therefore a tool for precision manufacturing and quality control.

  9. Vertical Crustal Motion Derived from Satellite Altimetry and Tide Gauges, and Comparisons with DORIS Measurements

    NASA Technical Reports Server (NTRS)

    Ray, R. D.; Beckley, B. D.; Lemoine, F. G.

    2010-01-01

    A somewhat unorthodox method for determining vertical crustal motion at a tide-gauge location is to difference the sea level time series with an equivalent time series determined from satellite altimetry, To the extent that both instruments measure an identical ocean signal, the difference will be dominated by vertical land motion at the gauge. We revisit this technique by analyzing sea level signals at 28 tide gauges that are colocated with DORIS geodetic stations. Comparisons of altimeter-gauge vertical rates with DORIS rates yield a median difference of 1.8 mm/yr and a weighted root-mean-square difference of2.7 mm/yr. The latter suggests that our uncertainty estimates, which are primarily based on an assumed AR(l) noise process in all time series, underestimates the true errors. Several sources of additional error are discussed, including possible scale errors in the terrestrial reference frame to which altimeter-gauge rates are mostly insensitive, One of our stations, Male, Maldives, which has been the subject of some uninformed arguments about sea-level rise, is found to have almost no vertical motion, and thus is vulnerable to rising sea levels. Published by Elsevier Ltd. on behalf of COSPAR.

  10. Structure-specific scalar intensity measures for near-source and ordinary earthquake ground motions

    USGS Publications Warehouse

    Luco, N.; Cornell, C.A.

    2007-01-01

    Introduced in this paper are several alternative ground-motion intensity measures (IMs) that are intended for use in assessing the seismic performance of a structure at a site susceptible to near-source and/or ordinary ground motions. A comparison of such IMs is facilitated by defining the "efficiency" and "sufficiency" of an IM, both of which are criteria necessary for ensuring the accuracy of the structural performance assessment. The efficiency and sufficiency of each alternative IM, which are quantified via (i) nonlinear dynamic analyses of the structure under a suite of earthquake records and (ii) linear regression analysis, are demonstrated for the drift response of three different moderate- to long-period buildings subjected to suites of ordinary and of near-source earthquake records. One of the alternative IMs in particular is found to be relatively efficient and sufficient for the range of buildings considered and for both the near-source and ordinary ground motions. ?? 2007, Earthquake Engineering Research Institute.

  11. Interexaminer reliability of cervical motion palpation using continuous measures and rater confidence levels

    PubMed Central

    Cooperstein, Robert; Young, Morgan; Haneline, Michael

    2013-01-01

    Introduction: Motion palpators usually rate the movement of each spinal level palpated, and their reliability is assessed based upon discrete paired observations. We hypothesized that asking motion palpators to identify the most fixated cervical spinal level to allow calculating reliability at the group level might be a useful alternative approach. Methods: Three examiners palpated 29 asymptomatic supine participants for cervical joint hypomobility. The location of identified hypomobile sites was based on their distance from the T1 spinous process. Interexaminer concordance was estimated by calculating Intraclass Correlation Coefficient (ICC) and mean absolute differences (MAD) values, stratified by degree of examiner confidence. Results: For the entire participant pool, ICC [2,1] = 0.61, judged “good.” MAD=1.35 cm, corresponding to mean interexaminer differences of about 75% of one cervical vertebral level. Stratification by examiner confidence levels resulted in small subgroups with equivocal results. Discussion and Conclusion: A continuous measures study methodology for assessing cervical motion palpation reliability showed more examiner concordance than was usually the case in previous studies using discrete methodology. PMID:23754861

  12. SU-C-210-04: Considerable Pancreatic Tumor Motion During Breath-Hold Measured Using Intratumoral Fiducials On Fluoroscopic Movies

    SciTech Connect

    Lens, E; Horst, A van der; Versteijne, E; Tienhoven, G van; Bel, A

    2015-06-15

    Purpose: Using a breath hold (BH) technique during radiotherapy of pancreatic tumors is expected to reduce intra-fractional motion. The aim of this study was to evaluate the tumor motion during BH. Methods: In this pilot study, we included 8 consecutive pancreatic cancer patients. All had 2– 4 intratumoral gold fiducials. Patients were asked to perform 3 consecutive 30-second end-inhale BHs on day 5, 10 and 15 of their three-week treatment. During BH, airflow through a mouthpiece was measured using a spirometer. Any inadvertent flow of air during BH was monitored for all patients. We measured tumor motion on lateral fluoroscopic movies (57 in total) made during BH. In each movie the fiducials as a group were tracked over time in superior-inferior (SI) and anterior-posterior (AP) direction using 2-D image correlation between consecutive frames. We determined for each patient the range of intra-BH motion over all movies; we also determined the absolute means and standard deviations (SDs) for the entire patient group. Additionally, we investigated the relation between inadvertent airflow during BH and the intra-BH motion. Results: We found intra-BH tumor motion of up to 12.5 mm (range, 1.0–12.5 mm) in SI direction and up to 8.0 mm (range, 1.0–8.0 mm) in AP direction. The absolute mean motion over the patient population was 4.7 (SD: 3.0) mm and 2.8 (SD: 1.2) mm in the SI and AP direction, respectively. Patients were able to perform stable consecutive BHs; during only 20% of the movies we found very small airflows (≤ 65 ml). These were mostly stepwise in nature and could not explain the continuous tumor motions we observed. Conclusion: We found substantial (up to 12.5 mm) pancreatic tumor motion during BHs. We found minimal inadvertent airflow, seen only during a minority of BHs, and this did not explain the obtained results. This work was supported by the foundation Bergh in het Zadel through the Dutch Cancer Society (KWF Kankerbestrijding) project No. UVA 2011-5271.

  13. Internal models of target motion: expected dynamics overrides measured kinematics in timing manual interceptions.

    PubMed

    Zago, Myrka; Bosco, Gianfranco; Maffei, Vincenzo; Iosa, Marco; Ivanenko, Yuri P; Lacquaniti, Francesco

    2004-04-01

    Prevailing views on how we time the interception of a moving object assume that the visual inputs are informationally sufficient to estimate the time-to-contact from the object's kinematics. Here we present evidence in favor of a different view: the brain makes the best estimate about target motion based on measured kinematics and an a priori guess about the causes of motion. According to this theory, a predictive model is used to extrapolate time-to-contact from expected dynamics (kinetics). We projected a virtual target moving vertically downward on a wide screen with different randomized laws of motion. In the first series of experiments, subjects were asked to intercept this target by punching a real ball that fell hidden behind the screen and arrived in synchrony with the visual target. Subjects systematically timed their motor responses consistent with the assumption of gravity effects on an object's mass, even when the visual target did not accelerate. With training, the gravity model was not switched off but adapted to nonaccelerating targets by shifting the time of motor activation. In the second series of experiments, there was no real ball falling behind the screen. Instead the subjects were required to intercept the visual target by clicking a mousebutton. In this case, subjects timed their responses consistent with the assumption of uniform motion in the absence of forces, even when the target actually accelerated. Overall, the results are in accord with the theory that motor responses evoked by visual kinematics are modulated by a prior of the target dynamics. The prior appears surprisingly resistant to modifications based on performance errors. PMID:14627663

  14. Indoor air quality measurements in 38 Pacific Northwest commercial buildings

    SciTech Connect

    Turk, B.H.; Brown, J.T.; Geisling-Sobotka, K.; Froehlich, D.A.; Grimsrud, D.T.; Harrison, J.; Revzan, K.L.

    1986-06-01

    A Bonneville Power Administration-funded study monitored ventilation rates and a variety of indoor air pollutants in 38 Pacific Northwest commercial buildings. The buildings ranged in age from 6 months to 90 years, in size from 864 to 34,280 m/sup 2/, and occupancy from 25 to 2500 people. Building average formaldehyde (HCHO) concentrations were below the 20 ppB detection limit in 48% of the buildings. Nitrogen dioxide (NO/sub 2/) concentration averages ranged from 5 ppB to 43 ppB and were lower than outdoor concentrations in 8 of 13 buildings. At only one site, an elementary school classroom, did carbon dioxide (CO/sub 2/) exceed 1000 ppM. Radon (Rn) levels were elevated in one building with an average concentration of 7.4 pCiL/sup -1/. Respirable particles (RSP) concentrations in smoking areas in 32 buildings had a geometric mean of 44 ..mu..g m/sup -3/ and ranged up to 308 ..mu..g m/sup -3/ at one site. In non-smoking areas the geometric mean RSP was 15 ..mu..g m/sup -3/. Outside air ventilation rates did not appear to be the single dominant parameter in determining indoor pollutant concentrations. Measured pollutant concentrations in 2 ''complaint'' buildings were below accepted guidelines. The cause of the complaints was not identified.

  15. Errors in measurement of three-dimensional motions of the stapes using a laser Doppler vibrometer system.

    PubMed

    Sim, Jae Hoon; Lauxmann, Michael; Chatzimichalis, Michail; Röösli, Christof; Eiber, Albrecht; Huber, Alexander M

    2010-12-01

    Previous studies have suggested complex modes of physiological stapes motions based upon various measurements. The goal of this study was to analyze the detailed errors in measurement of the complex stapes motions using laser Doppler vibrometer (LDV) systems, which are highly sensitive to the stimulation intensity and the exact angulations of the stapes. Stapes motions were measured with acoustic stimuli as well as mechanical stimuli using a custom-made three-axis piezoelectric actuator, and errors in the motion components were analyzed. The ratio of error in each motion component was reduced by increasing the magnitude of the stimuli, but the improvement was limited when the motion component was small relative to other components. This problem was solved with an improved reflectivity on the measurement surface. Errors in estimating the position of the stapes also caused errors on the coordinates of the measurement points and the laser beam direction relative to the stapes footplate, thus producing errors in the 3-D motion components. This effect was small when the position error of the stapes footplate did not exceed 5 degrees.

  16. INVESTIGATION OF THE ERRORS IN SLOAN DIGITAL SKY SURVEY PROPER-MOTION MEASUREMENTS USING SAMPLES OF QUASARS

    SciTech Connect

    Dong Ruobing; Gunn, James; Knapp, Gillian; Rockosi, Constance

    2011-10-15

    We investigate in detail the probability distribution function (pdf) of the proper-motion measurement errors in the SDSS+USNO-B proper-motion catalog of Munn et al. using clean quasar samples. The pdf of the errors is well represented by a Gaussian core with extended wings, plus a very small fraction (<0.1%) of 'outliers'. We find that while formally the pdf could be well fit by a five-parameter fitting function, for many purposes it is also adequate to represent the pdf with a one-parameter approximation to this function. We apply this pdf to the calculation of the confidence intervals on the true proper motion for an SDSS+USNO-B proper-motion measurement, and discuss several scientific applications of the SDSS proper-motion catalog. Our results have various applications in studies of the galactic structure and stellar kinematics. Specifically, they are crucial for searching hyper-velocity stars in the Galaxy.

  17. Fallspeeds and Vertical Air Motions in Stratiform Rain Derived from ER-2 Doppler Radar Observations

    NASA Technical Reports Server (NTRS)

    Heymsfield, G. M.; Tian, L.

    2000-01-01

    The Tropical Rain Measuring Mission (TRMM) conducted several intensive field validation campaigns for improved understanding of Tropical precipitation systems. Two of the campaigns (TEFLUN in Florida and Texas, and LBA in Brazil) utilized: the NASA ER-2 high-altitude (20 km) remote sensing aircraft instrumented with the ER-2 Doppler Radar (EDOP), the University of North Dakota Citation microphysics aircraft, and the NCAR S-POL polarization radar. This paper focuses on EDOP-derived fallspeeds and vertical velocities in the rain regions of two stratiform cases (5 September 1998 along the east coast of Florida, and 17 February 1999 in Amazonia in Brazil). These cases were sampled in situ microphysically by the Citation and reported elsewhere in this meeting; the main emphasis of this paper will be on the airborne radar measurements and inferences from them.

  18. Monitoring motion and measuring relative position of the Chang'E-3 rover

    NASA Astrophysics Data System (ADS)

    Liu, Qinghui; Zheng, Xin; Huang, Yong; Li, Peijia; He, Qingbao; Wu, Yajun; Guo, Li; Tang, Mingle

    2014-11-01

    Same-beam very long baseline interferometry observations were performed between the rover and the lander of Chang'E-3 and differential phase delay data were obtained with the minimum random error of about 0.03 ps. These data were used to monitor the rover motions, as small as several centimeters, including movement, turning, and attitude adjustment. The relative position between the rover and the lander was precisely measured with an accuracy of 1 m, which is an improvement of 10 times compared with that of the Apollo project.

  19. Measurements of the Motion of Plasma Filaments in a Plasma Ball

    SciTech Connect

    Campanell, M.; Laird, J.; Provost, T.; Vasquez, S.; Zweben, S. J.

    2010-01-26

    Measurements were made of the motion of the filamentary structures in a plasma ball using high speed cameras and other optical detectors. These filaments traverse the ball radially at ~106 cm/sec at the driving frequency of ~26 kHz, and drift upward through the ball at ~1 cm/sec. Varying the applied high voltage and frequency caused the number, length, and diameter of the filaments to change. A custom plasma ball was constructed to observe the effects of varying gas pressure and species on the filament structures.

  20. Species measurements in a hypersonic, hydrogen-air, combustion wake

    SciTech Connect

    Skinner, K.A.; Stalker, R.J.

    1996-09-01

    A continuously sampling, time-of-flight mass spectrometer has been used to measure relative species concentrations in a two-dimensional, hydrogen-air combustion wake at mainstream Mach numbers exceeding 5. The experiments, in a free piston shock tunnel, yielded distributions of hydrogen, oxygen, nitrogen, water, and nitric oxide at stagnation enthalpies ranging from 5.6 MJ/kg to 12.2 MJ/kg and at a distance of approximately 100s times the thickness of the initial hydrogen jet. The amount of hydrogen mixed in stoichiometric proportions was approximately independent of the stagnation enthalpy, despite the fact that the proportion of hydrogen in the wake was increased with stagnation enthalpy. Roughly 50% of the mixed hydrogen underwent combustion at the highest enthalpy. The proportion of hydrogen reacting to water could be approximately predicted using reaction rates based on mainstream temperatures.

  1. Species measurements in a hypersonic, hydrogen-air, combustion wake

    NASA Technical Reports Server (NTRS)

    Skinner, K. A.; Stalker, R. J.

    1995-01-01

    A continuously sampling, time-of-flight mass spectrometer has been used to measure relative species concentrations in a two-dimensional, hydrogen-air combustion wake at mainstream Mach numbers exceeding 5. The experiments, which were conducted in a free piston shock tunnel, yielded distributions of hydrogen, oxygen, nitrogen, water and nitric oxide at stagnation enthalpies ranging from 5.6 MJ kg(exp -1) to 1.2 MJ kg(exp -1) and at a distance of approximately 100 times the thickness of the initial hydrogen jet. The amount of hydrogen that was mixed in stoichiometric proportions was approximately independent of the stagnation enthalpy, in spite of the fact that the proportion of hydrogen in the wake increased with stagnation enthalpy. Roughly 50 percent of the mixed hydrogen underwent combustion at the highest enthalpy. The proportion of hydrogen reacting to water could be approximately predicted using reaction rates based on mainstream temperatures.

  2. The feasibility of shoulder motion tracking during activities of daily living using inertial measurement units.

    PubMed

    Kirking, Bryan; El-Gohary, Mahmoud; Kwon, Young

    2016-09-01

    Measurements of shoulder kinematics during activities of daily living (ADL) can be used to evaluate patient function before and after treatment and help define device testing conditions. The purpose of this study was to demonstrate the feasibility of using wearable inertial measurement units (IMUs) to track shoulder joint angles while performing actual ADLs outside of laboratory simulations. IMU data of 5 subjects with normal shoulders was collected for 4h at the subjects' workplace and up to 4h off-work. An Unscented Kalman Filter (UKF) enhanced with gyroscope bias modeling and zero velocity updates demonstrated an accuracy of about 2° and was used to estimate relative upper arm angles from the IMU data. The overall averaged 95th percentile angles were: flexion 128.8°, abduction 128.4°, and external rotation 69.5°. These peaks angles are similar to other investigator's reports using laboratory simulations of ADLs measured with optical and electromagnetic technologies. Additionally, with a Fourier transform the 50th percentile frequency was determined and used to extrapolate the typical number of arm cycles in a 10year period to be 649,000. Application of the UKF with the additional drift correction made substantial improvements in shoulder tracking performance and this feasibility data suggests that IMUs with the UKF are suitable for extended use outside of laboratory settings. The data provides a novel description of arm motion during ADLs including an estimate for the 10 year cycle count of upper arm motion. PMID:27371783

  3. Use of power-line interference for adaptive motion artifact removal in biopotential measurements.

    PubMed

    Xu, Lin; Rooijakkers, Michael J; Rabotti, Chiara; Peuscher, Jan; Mischi, Massimo

    2016-01-01

    Motion artifacts (MA) have long been a problem in biopotential measurements. Adaptive filtering is widely used for optimal noise removal in many biomedical applications. However, the existing adaptive filtering methods involve the use of additional sensors, limiting the applicability of adaptive filtering for MA reduction. In the present study, a novel adaptive filtering method without need for additional sensors is proposed. In biopotential measurements, movement of the electrodes and their leads may cause variations not only in the skin and half-cell potential (motion artifacts), but also in the electrode-skin impedance. Such impedance variations may also cause power-line interference modulation (PLIM), resulting in additional spectral components around the power-line interference (PLI) in the frequency domain. Demodulation of the PLI may reflect the movement-induced electrode-skin impedance variation, and can therefore represent a reference signal for the adaptive filter. Preliminary validation on ECG measurements with seven volunteers showed a high correlation coefficient (R  =  0.97) between MA and PLIM, and excellent MA removal by the proposed adaptive filter, possibly leading to improved analysis of biopotential signals. PMID:26641265

  4. Correction of Doppler Rada Data for Aircraft Motion Using Surface Measurements and Recursive Least-Squares Estimation

    NASA Technical Reports Server (NTRS)

    Durden, S.; Haddad, Z.

    1998-01-01

    Observations of Doppler velocity of hydrometeors form airborne Doppler weather radars normally contains a component due to the aircraft motion. Accurate hydrometeor velocity measurements thus require correction by subtracting this velocity from the observed velocity.

  5. Dynamic force measurements for a high bar using 3D motion capturing.

    PubMed

    Cagran, C; Huber, P; Müller, W

    2010-03-01

    The displacement of a calibrated horizontal bar is used as a measure for forces acting on the bar itself during dynamic performances in artistic gymnastics. The high bar is loaded with known forces and the displacement is monitored by means of a Vicon motion capturing system. The calibration results are fitted according to the Euler-Bernoulli beam theory. After calibration, forces can straightforwardly be measured by multiplication of the bar displacement with the determined fit parameter. This approach is also able to account for non-central force application (two hands on the bar) and the effect of the bar's inertia. Uncertainties in measured forces are assessed to be +/-25 N plus an additional 1% for the unknown weight distribution between the two hands. PMID:19906379

  6. Measurement of total reduced sulfur compounds in ambient air

    SciTech Connect

    McQuaker, N.R.; Rajala, G.E.; Pengilly, D.

    1986-05-01

    Methods for the determination of total reduced sulfur (TRS) compounds in the ambient air based on coulometric detection (Philips Model PW 9700 analyzer) and thermal oxidation followed by detection using pulsed fluorescence (Teco Model 43 analyzer) have been evaluated. Analytical response factors, relative to H/sub 2/S, were determined for both the individual TRS compounds and compounds such as terpenes and carbonyl sulfide that may be a potential source of interference. The results for COS and terpenes indicate that in a typical monitoring situation normally encountered concentrations of these compounds are not expected to cause significant measurement bias. The results for the individual TRS compounds indicate that while variations in TRS composition are not a factor in assessing measurement bias for the thermal oxidation/pulsed fluorescence method, they are a factor for the Philips coulometric method; i.e., increasing positive measurement bias maybe introduced as the TRS composition shifts toward relatively less H/sub 2/S. Philips-Teco comparison data collected at a single site in the vicinity of three operating kraft pupil mills are compatible with these expectations. 8 references, 1 figure, 3 tables.

  7. Wash-out of ambient air contaminations for breath measurements.

    PubMed

    Maurer, F; Wolf, A; Fink, T; Rittershofer, B; Heim, N; Volk, T; Baumbach, J I; Kreuer, S

    2014-06-01

    In breath analysis, ambient air contaminations are ubiquitous and difficult to eliminate. This study was designed to investigate the reduction of ambient air background by a lung wash-out with synthetic air. The reduction of the initial ambient air volatile organic compound (VOC) intensity was investigated in the breath of 20 volunteers inhaling synthetic air via a sealed full face mask in comparison to inhaling ambient air. Over a period of 30 minutes, breath analysis was conducted using ion mobility spectrometry coupled to a multi-capillary column. A total of 68 VOCs were identified for inhaling ambient air or inhaling synthetic air. By treatment with synthetic air, 39 VOCs decreased in intensity, whereas 29 increased in comparison to inhaling ambient air. In total, seven VOCs were significantly reduced (P-value < 0.05). A complete wash-out of VOCs in this setting was not observed, whereby a statistically significant reduction up to 65% as for terpinolene was achieved. Our setting successfully demonstrated a reduction of ambient air contaminations from the airways by a lung wash-out with synthetic air.

  8. Air-Sea Interaction Measurements from the Controlled Towed Vehicle

    NASA Astrophysics Data System (ADS)

    Khelif, D.; Bluth, R. T.; Jonsson, H.; Barge, J.

    2014-12-01

    The Controlled Towed Vehicle (CTV) uses improved towed drone technology to actively maintain via a radar altimeter and controllable wing a user-set height that can be as low as the canonical reference height of 10 m above the sea surface. After take-off, the drone is released from the tow aircraft on a ~700-m stainless steel cable. We have instrumented the 0.23 m diameter and 2.13 m long drone with high fidelity instruments to measure the means and turbulent fluctuations of 3-D wind vector, temperature, humidity, pressure, CO2 and IR sea surface temperature. Data are recorded internally at 40 Hz and simultaneously transmitted to the tow aircraft via dedicated wireless Ethernet link. The CTV accommodates 40 kg of instrument payload and provides it with 250 W of continuous power through a ram air propeller-driven generator. Therefore its endurance is only limited by that of the tow aircraft.We will discuss the CTV development, the engineering challenges and solutions that have been successfully implemented to overcome them. We present results from recent flights as low as 9 m over the coastal ocean and comparisons of profiles and turbulent fluxes from the CTV and the tow aircraft. Manned aircraft operation at low-level boundary-layer flights is very limited. Dropsondes and UAS (Unmanned Aerial Systems) and UAS are alternates for measurements near the ocean surface. However, dropsondes have limited sensor capability and do not measure fluxes, and most present UAS vehicles do not have the payload and power capacity nor the low-flying ability in high winds over the oceans. The CTV therefore, fills a needed gap between the dropsondes, in situ aircraft, and UAS. The payload, capacity and power of the CTV makes it suitable for a variety of atmospheric research measurements. Other sensors to measure aerosol, chemistry, radiation, etc., could be readily accommodated in the CTV.

  9. A Non-Contact Measurement System for the Range of Motion of the Hand

    PubMed Central

    Pham, Trieu; Pathirana, Pubudu N.; Trinh, Hieu; Fay, Pearse

    2015-01-01

    An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers. PMID:26225976

  10. ARM - Midlatitude Continental Convective Clouds Experiment (MC3E): Multi-Frequency Profilers, Vertical Air Motion (williams-vertair)

    DOE Data Explorer

    Williams, Christopher; Jensen, Mike

    2012-11-06

    This data was collected by the NOAA 449-MHz and 2.8-GHz profilers in support of the Department of Energy (DOE) and NASA sponsored Mid-latitude Continental Convective Cloud Experiment (MC3E). The profiling radars were deployed in Northern Oklahoma at the DOE Atmospheric Radiation Mission (ARM) Southern Great Plans (SGP) Central Facility from 22 April through 6 June 2011. NOAA deployed three instruments: a Parsivel disdrometer, a 2.8-GHz profiler, and a 449-MHz profiler. The parasivel provided surface estimates of the raindrop size distribution and is the reference used to absolutely calibrate the 2.8 GHz profiler. The 2.8-GHz profiler provided unattenuated reflectivity profiles of the precipitation. The 449-MHz profiler provided estimates of the vertical air motion during precipitation from near the surface to just below the freezing level. By using the combination of 2.8-GHz and 449-MHz profiler observations, vertical profiles of raindrop size distributions can be retrieved. The profilers are often reference by their frequency band: the 2.8-GHz profiler operates in the S-band and the 449-MHz profiler operates in the UHF band. The raw observations are available as well as calibrated spectra and moments. This document describes how the instruments were deployed, how the data was collected, and the format of the archived data.

  11. Measurement-while-drilling (MWD) development for air drilling

    SciTech Connect

    Rubin, L.A.; Harrison, W.H.

    1992-01-01

    The objective of this program is to tool-harden and make commercially available an existing wireless MWD tool to reliably operate in an air, air-mist, or air-foam environment during Appalachian Basin oil and gas directional drilling operations in conjunction with downhole motors and/or (other) bottom-hole assemblies. The application of this technology is required for drilling high angle (holes) and horizontal well drilling in low-pressure, water sensitive, tight gas formations that require air, air-mist, and foam drilling fluids. The basic approach to accomplishing this objective was to modify GEC's existing electromagnetic (e-m) CABLELESS''{trademark} MWD tool to improve its reliability in air drilling by increasing its tolerance to higher vibration and shock levels (hardening). Another important aim of the program is to provide for continuing availability of the resultant tool for use on DOE-sponsored, and other, air-drilling programs.

  12. Measurement-while-drilling (MWD) development for air drilling

    SciTech Connect

    Rubin, L.A.; Harrison, W.H.

    1992-06-01

    The objective of this program is to tool-harden and make commercially available an existing wireless MWD tool to reliably operate in an air, air-mist, or air-foam environment during Appalachian Basin oil and gas directional drilling operations in conjunction with downhole motors and/or (other) bottom-hole assemblies. The application of this technology is required for drilling high angle (holes) and horizontal well drilling in low-pressure, water sensitive, tight gas formations that require air, air-mist, and foam drilling fluids. The basic approach to accomplishing this objective was to modify GEC`s existing electromagnetic (e-m) ``CABLELESS``{trademark} MWD tool to improve its reliability in air drilling by increasing its tolerance to higher vibration and shock levels (hardening). Another important aim of the program is to provide for continuing availability of the resultant tool for use on DOE-sponsored, and other, air-drilling programs.

  13. Synoptic Mapping of Chemical Composition, Thermal Structure, and Air Motion from UARS Observations

    NASA Technical Reports Server (NTRS)

    Salby, Murry L.

    1999-01-01

    An operational mapping algorithm was developed to process measurements of individual species observed by different satellite instruments on board UARS. Based on Fast Fourier Synoptic Mapping (FFSM), the algorithm accounts for the precessing orbit of UARS, the error of individual instruments, and gaps associated with instrument duty cycle and the satellite yaw maneuver. It provides synoptic structure and evolution on periods as short as 1 day, derived collectively from all observations of an individual species. The algorithm was applied to synoptically map temperature, thickness, and several chemical constituents observed by the instruments: MLS, CLAES, ISAMS, and HALOE. Each field variable observed by these instruments was mapped twice-daily in continuous global time series several months long. Mapped behavior produced via FFSM was compared against standard archived products generated via Kalman filtering. The standard map products reveal similar behavior, but are limited to features of larger scale. Tracer structure that develops through flow deformation and attending transport is therefore represented in those products more coarsely, eventually being sheared down to scales that are no longer represented properly. The synoptic time series also reveal a diurnal cycle for several of the constituents, one that emerges clearly in their space-time spectra. The zonal and meridional structure of diurnal variability was mapped by filtering the space-time spectrum, an intermediate product of FFSM, to those scales resolved by the UARS sampling. Geographical variations of the diurnal cycle have also been evaluated in its seasonal-mean structure by compositing distributions at individual local times. Both were compared to diurnal variations in chemical models and in dynamical models that account for transport by the diurnal tide. Diurnal variations were found to introduce spurious behavior into the archived products generated via Kalman filtering, behavior that is

  14. High resolution measurement of striation patterns and sarcomere motions in cardiac muscle cells.

    PubMed Central

    Krueger, J W; Denton, A

    1992-01-01

    We describe an extension of the method of Myers et al. (1982) to measure with high precision the uniformity of contractile motions that occur between sarcomeres in the isolated cardiac muscle cell (guinea pig and rat). The image of the striations, observed with modulation contrast microscopy, was detected by a linear array of photodiodes. Sarcomere length was measured greater than 500/s from the frequency of the array's video signal at two selectable regions of the cell. A precision test grating demonstrated that method resolves known differences in the spacing between two contiguous striations to +/- 0.01 micron and that the effects of image translation and microscopic resolution are minor. The distribution of striation spacing appears to be discrete in isolated segments of the cell, and patches of fairly uniform length can be identified that are laterally contiguous. When electrically triggered, contraction is synchronous and the sarcomeres shorten and relengthen smoothly. The contrast between the striations is transiently enhanced during relengthening, an indication that the contracting cell can not be treated as a simple grating. Pauses that occur during late in relengthening (and transient contractile alternans) are characterized by very synchronized activity. These forms of irregular contractile behavior are not explained by desynchronization of a mechanism of release of intracellular calcium. A companion article describes application of the technique to study the nonuniform motions that occur between sarcomeres. Images FIGURE 1 FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 PMID:1540686

  15. Quantum noise in the position measurement of a cavity mirror undergoing Brownian motion

    NASA Astrophysics Data System (ADS)

    Jacobs, K.; Tittonen, I.; Wiseman, H. M.; Schiller, S.

    1999-07-01

    We perform a quantum theoretical calculation of the noise power spectrum for a phase measurement of the light output from a coherently driven optical cavity with a freely moving rear mirror. We examine how the noise resulting from the quantum back action appears among the various contributions from other noise sources. We do not assume an ideal (homodyne) phase measurement, but rather consider phase-modulation detection, which we show has a different shot noise level. We also take into account the effects of thermal damping of the mirror, losses within the cavity, and classical laser noise. We relate our theoretical results to experimental parameters, so as to make direct comparisons with current experiments simple. We also show that in this situation, the standard Brownian motion master equation is inadequate for describing the thermal damping of the mirror, as it produces a spurious term in the steady-state phase-fluctuation spectrum. The corrected Brownian motion master equation [L. Diosi, Europhys. Lett. 22, 1 (1993)] rectifies this inadequacy.

  16. Adaptation of the S-5-S pendulum seismometer for measurement of rotational ground motion

    NASA Astrophysics Data System (ADS)

    Knejzlík, Jaromír; Kaláb, Zdeněk; Rambouský, Zdeněk

    2012-10-01

    The Russian electrodynamic seismometer model S-5-S has been adapted for the measurement of rotational ground motion. The mechanical system of the original S-5-S seismometer consists of electrodynamic sensing and damping transducer coils mounted on an asymmetrical double-arm pendulum. This pendulum is suspended on a footing using two pairs of crossed flat springs, which operate as the axis of rotation. The pendulum is stabilised by an additional spring. The S-5-S can be used either as a vertical or as a horizontal sensor. The adaptation of the S-5-S seismometer described below involves removal of the additional spring and installation of an additional mass on the damping arm. Strain gauge angle sensors are installed on one pair of the crossed flat springs. The main dynamic parameters of the rotational seismometer created in this way, i.e. the natural period and damping, are controlled electronically by feedback currents proportional to the angular displacement and angular velocity, both fed to the damping transducer coil. This new seismometer, named the S-5-SR, enables measurement of the rotational component of ground motion around the horizontal or the vertical axes. The output signal from this S-5-SR seismometer can be proportional either to rotational displacement or rotational velocity.

  17. Calculated and Measured Air and Soil Freeze-Thaw Frequencies.

    NASA Astrophysics Data System (ADS)

    Baker, Donald G.; Ruschy, David L.

    1995-10-01

    Freeze-thaw frequencies calculated by eight different counting methods were compared using daily maximum and minimum temperatures from eight north-central United States National Weather Service (NWS) stations. These frequencies were also compared to those obtained using hourly air temperature data from six of the same NWS stations. In addition, the calculated frequencies were compared to measured freeze-thaw frequencies at several depths in a bare soil and a sod-covered soil at the University of Minnesota St. Paul campus climatological observatory.The necessary acceptance of the idealized daily heating cycle when using daily maximum and minimum air temperature data resulted in a higher occurrence of calculated freeze-thaw events than those obtained with hourly data; one method gave 23% more freeze-thaw events with the daily maximum and minimum temperatures.With the freeze-thaw phenomenon centered upon those months in which the mean temperature hovers near O°C, a bimodal frequency occurs at the northern stations (October and April, as at International Falls, Minnesota, and November and March at Fargo, North Dakota), while in warmer climates the bimodal characteristic is replaced by a single-peak frequency in January as at Sedalia and West Plains, Missouri.In the comparison between the calculated freeze-thaw frequencies based on daily maximum and minimum values and the hourly temperature measurements at several heights between the surface and the temperature shelter at the climatological observatory, it was found that the annual total frequencies increased as the height above the surface decreased. For the shallowest height above the surface there was an approximate 13% increase over those measured in the shelter with hourly temperature data.The annual total frequencies of the calculated freeze-thaw events obtained with the daily maximum and minimum temperature measurements in the shelter approximated those actually occurring at the 1-cm depth in a bare soil at the

  18. Flammability measurements of difluoromethane in air at 100 C

    SciTech Connect

    Grosshandler, W.L.; Donnelly, M.K.; Womeldorf, C.

    1999-07-01

    Difluoromethane (CH{sub 2}F{sub 2}, or R-32) is a candidate to replace currently used ozone-depleting chlorofluorocarbon refrigerants. Because CH{sub 2}F{sub 2} is flammable, it is necessary to assess the hazard posed by a leak in a refrigeration machine. The currently accepted method for determining flammability, ASTM E 681, has difficulty discerning the flammability boundary for weak fuels such as CH{sub 2}F{sub 2}. This paper describes an alternative approach to identify the limits of flammability, using a twin, premixed counter-flow flame. By using the extinction of an already established flame, the point dividing flammable from non-flammable becomes unambiguous. The limiting extinction mixture changes with stretch rate, so it is convenient to report the flammability limit as the value extrapolated to a zero stretch condition. In the burner, contoured nozzles with outlet diameters of 12 mm are aligned counter to each other and spaced 12 mm apart. The lean flammability limit of CH{sub 2}F{sub 2} in dry air at room temperature was previously reported by the authors to be a mole fraction of 0.14, using the twin counter-flow flame method. In the current study, relative humidity was not found to affect the lean limit. Increasing the temperature of the premixed fuel and air to 100 C is shown to extend the flammability limit in the lean direction to 0.13. The rich limit of CH{sub 2}F{sub 2} found using the counter-flow method is around 0.27. The uncertainties of the measurements are presented and the results compared to data in the literature.

  19. A Review of the Accuracy and Utility of Motion Sensors to Measure Physical Activity of Frail, Older Hospitalized Patients.

    PubMed

    McCullagh, Ruth; Brady, Noeleen M; Dillon, Christina; Horgan, N Frances; Timmons, Suzanne

    2016-07-01

    The purpose of this review was to examine the utility and accuracy of commercially available motion sensors to measure step-count and time spent upright in frail older hospitalized patients. A database search (CINAHL and PubMed, 2004-2014) and a further hand search of papers' references yielded 24 validation studies meeting the inclusion criteria. Fifteen motion sensors (eight pedometers, six accelerometers, and one sensor systems) have been tested in older adults. Only three have been tested in hospital patients, two of which detected postures and postural changes accurately, but none estimated step-count accurately. Only one motion sensor remained accurate at speeds typical of frail older hospitalized patients, but it has yet to be tested in this cohort. Time spent upright can be accurately measured in the hospital, but further validation studies are required to determine which, if any, motion sensor can accurately measure step-count. PMID:26583827

  20. Next Generation Air Measurements for Fugitive, Area Source, and Fence Line Applications

    EPA Science Inventory

    Next generation air measurements (NGAM) is an EPA term for the advancing field of air pollutant sensor technologies, data integration concepts, and geospatial modeling strategies. Ranging from personal sensors to satellite remote sensing, NGAM systems may provide revolutionary n...

  1. Unrestricted release measurements with ambient air ionization monitors

    SciTech Connect

    MacArthur, D.; Gunn, R.; Dockray, T.; Luff, C.

    1999-03-01

    Radiation monitoring systems based on the long-range alpha detection (LRAD) technique, such as the BNFL Instruments IonSens{trademark}, provide a single contamination measurement for an entire object rather than the more familiar individual readings for smaller surface areas. The LRAD technique relies on the ionization of ambient air molecules by alpha particles, and the subsequent detection of these ions, rather than direct detection of the alpha particles themselves. A single monitor can detect all of the ions produced over a large object and report a total contamination level for the entire surface of that object. However, both the unrestricted release limits specified in USDOE Order 5400.5 (and similar documents in other countries), and the definitions of radioactive waste categories, are stated in terms of contamination per area. Thus, conversion is required between the total effective contamination as measured by the LRAD-based detector and the allowable release limits. In addition, since the release limits were not written assuming an averaging detector system, the method chosen to average the assumed contamination over the object can have a significant impact on the effective sensitivity of the detector.

  2. Air shower arrival directions measured at Buckland Park

    NASA Technical Reports Server (NTRS)

    Gerhardy, P. R.; Clay, R. W.; Patterson, J. R.; Prescott, J. R.; Gregory, A. G.; Protheroe, R. J.

    1985-01-01

    The Buckland Park air shower array was operated for 3 years from 1979 to 1981 particularly for the study of anisotropies in the region of the knee of the size spectrum. The array which has been described in detail elsewhere was situated at a latitude of 35 S and had an effective size threshold of approx 3 x 10 to the 5th power particles (approx 3 x 10 to the 15th power Ev for vertical showers). A number of results from this experiment have already been published including anisotropy analyses (Gerhardy and Clay, 1983) and searches for very high energy gamma ray sources. The final distribution of measured shower arrival directions are presented here. These 1.3 x 10 to the 5th power events were selected as indicated in detail in Gerhardy and Clay (1983) and were essentially those events with well measured arrival directions. They are the same data set used in the above reference but no complete sky map has previously been presented.

  3. Hazard Assessment of Chemical Air Contaminants Measured in Residences

    SciTech Connect

    Logue, J.M.; McKone, T.E.; Sherman, M. H.; Singer, B.C.

    2010-05-10

    Identifying air pollutants that pose a potential hazard indoors can facilitate exposure mitigation. In this study, we compiled summary results from 77 published studies reporting measurements of chemical pollutants in residences in the United States and in countries with similar lifestyles. These data were used to calculate representative mid-range and upper bound concentrations relevant to chronic exposures for 267 pollutants and representative peak concentrations relevant to acute exposures for 5 activity-associated pollutants. Representative concentrations are compared to available chronic and acute health standards for 97 pollutants. Fifteen pollutants appear to exceed chronic health standards in a large fraction of homes. Nine other pollutants are identified as potential chronic health hazards in a substantial minority of homes and an additional nine are identified as potential hazards in a very small percentage of homes. Nine pollutants are identified as priority hazards based on the robustness of measured concentration data and the fraction of residences that appear to be impacted: acetaldehyde; acrolein; benzene; 1,3-butadiene; 1,4-dichlorobenzene; formaldehyde; naphthalene; nitrogen dioxide; and PM{sub 2.5}. Activity-based emissions are shown to pose potential acute health hazards for PM{sub 2.5}, formaldehyde, CO, chloroform, and NO{sub 2}.

  4. Relation of motion sickness susceptibility to vestibular and behavioral measures of orientation

    NASA Technical Reports Server (NTRS)

    Peterka, Robert J.

    1995-01-01

    The objective is to determine the relationship of motion sickness susceptibility to vestibulo-ocular reflexes (VOR), motion perception, and behavioral utilization of sensory orientation cues for the control of postural equilibrium. The work is focused on reflexes and motion perception associated with pitch and roll movements that stimulate the vertical semicircular canals and otolith organs of the inner ear. This work is relevant to the space motion sickness problem since 0 g related sensory conflicts between vertical canal and otolith motion cues are a likely cause of space motion sickness.

  5. 1991 EPA/AWMA international symposium on measurement of toxic and related air pollutants

    SciTech Connect

    Gay, B.W. Jr.

    1991-01-01

    The purpose of this symposium was to provide a forum for exchange of information on the measurement of toxic and related air pollutants. The conference included presentations on the following: ozone precursors; atmospheric chemistry and fate of toxic pollutants; measurement of particulates and acidic aerosols; cloud water chemistry; asbestos exposure assessment; Staten Island/NJ Urban Air Toxics Assessment Project; personal exposure monitors; mobile sources emissions characterization; VOC monitoring for Clean Air Act Amendment requirement; product emission measurement in test chambers; USA/USSR joint air pollution study; VOC monitoring techniques; measurement of VOCs; measurement of polar volatile organics; exposure assessment; remote sensing for emissions monitoring; measurement methods development; measurement of hazardous waste emissions; chemometrics and environmental data analysis; source monitoring; air pollution dispersion modeling; measurement and data analysis of indoor toxic air contaminants; and environmental quality assurance. Two hundred seventeen papers have been processed separately for inclusion in the appropriate data bases.

  6. Note: Compact and light displacement sensor for a precision measurement system in large motion.

    PubMed

    Lee, Sang Heon

    2015-08-01

    We developed a compact and light displacement sensor applicable to systems that require wide range motions of its sensing device. The proposed sensor utilized the optical pickup unit of the optical disk drive, which has been used applied to atomic force microscopy (AFM) because of its compactness and lightness as well as its high performance. We modified the structure of optical pickup unit and made the compact sensor driver attachable to a probe head of AFM to make large rotation. The feasibilities of the developed sensor for a general probe-moving measurement device and for probe-rotating AFM were verified. Moreover, a simple and precise measurement of alignment between centers of rotator and probe tip in probe-rotation AFM was experimentally demonstrated using the developed sensor.

  7. First mirror contamination studies for polarimetry motional Stark effect measurements for ITER

    SciTech Connect

    Kuldkepp, M.; Rachlew, E.; Hawkes, N.C.; Schunke, B.

    2004-10-01

    The motional Stark effect (MSE) diagnostic on the International Thermonuclear Experimental Reactor will need to guide the light through a labyrinth of mirrors to provide neutron shielding. Knowledge of how the mirrors change the polarization is essential for accurate determination of the q profile. The optical properties of the plasma facing mirror are also expected to change with time due to deposition/erosion. For the purpose of examining this experimentally a detector system, identical to the JET MSE system, using twin photoelastic modulators was constructed. Measurements have been performed on freshly prepared mirrors, on mirrors after exposure to plasmas in Tore Supra, and labyrinth designs. The result shows a significant effect on the optical properties and demonstrate the need for in situ monitoring. The measured properties of the labyrinth closely follow the Mueller matrix formalism. With a correct choice of material the angle change introduced by the four mirrors furthest away from the plasma will be below 1 deg.

  8. Measuring nanomechanical motion with an imprecision below the standard quantum limit

    SciTech Connect

    Anetsberger, G.; Arcizet, O.; Gavartin, E.; Unterreithmeier, Q. P.; Weig, E. M.; Kotthaus, J. P.; Gorodetsky, M. L.; Kippenberg, T. J.

    2010-12-15

    We report a room-temperature measurement of nanomechanical motion with an imprecision below the standard quantum limit (SQL), using cavity-enhanced optical near fields. Fundamental thermodynamical cavity frequency fluctuation limits the total imprecision to 3 dB below the SQL at room temperature [corresponding to (530 am/{radical}(Hz)){sup 2} in absolute units] and is expected to reduce to negligible values at moderate cryogenic temperatures. Coupling strengths exceeding those required to reach the SQL by more than two orders of magnitude are achieved, allowing a shot-noise limited imprecision more than 10 dB below the SQL. The transducer, thus, in principle, allows access to the quantum backaction dominated regime, a prerequisite for exploring quantum backaction, measurement-induced squeezing, and obtaining sub-SQL sensitivity using backaction evading techniques.

  9. Note: Compact and light displacement sensor for a precision measurement system in large motion

    SciTech Connect

    Lee, Sang Heon

    2015-08-15

    We developed a compact and light displacement sensor applicable to systems that require wide range motions of its sensing device. The proposed sensor utilized the optical pickup unit of the optical disk drive, which has been used applied to atomic force microscopy (AFM) because of its compactness and lightness as well as its high performance. We modified the structure of optical pickup unit and made the compact sensor driver attachable to a probe head of AFM to make large rotation. The feasibilities of the developed sensor for a general probe-moving measurement device and for probe-rotating AFM were verified. Moreover, a simple and precise measurement of alignment between centers of rotator and probe tip in probe-rotation AFM was experimentally demonstrated using the developed sensor.

  10. THE PROPER MOTION OF PSR J1550-5418 MEASURED WITH VLBI: A SECOND MAGNETAR VELOCITY MEASUREMENT

    SciTech Connect

    Deller, A. T.; Camilo, F.; Halpern, J. P.; Reynolds, J. E.

    2012-03-20

    The formation mechanism of neutron stars with extremely large magnetic field strengths (magnetars) remains unclear. Some formation scenarios predict that magnetars should be born with extremely high space velocities, >1000 km s{sup -1}. Using the Long Baseline Array in Australia, we have measured the proper motion of the intermittently radio-bright magnetar PSR J1550-5418 (1E 1547.0-5408): {mu} = 9.2 {+-} 0.6 mas yr{sup -1}. For a likely distance of 6 {+-} 2 kpc, the implied transverse velocity is 280{sup +130}{sub -120} km s{sup -1} after correcting for Galactic rotation. Along with the Almost-Equal-To 200 km s{sup -1} transverse velocity measured for the magnetar XTE J1810-197, this result suggests that formation pathways producing large magnetic fields do not require very large birth kicks.

  11. Motion sickness.

    PubMed

    Golding, J F

    2016-01-01

    Over 2000 years ago the Greek physician Hippocrates wrote, "sailing on the sea proves that motion disorders the body." Indeed, the word "nausea" derives from the Greek root word naus, hence "nautical," meaning a ship. The primary signs and symptoms of motion sickness are nausea and vomiting. Motion sickness can be provoked by a wide variety of transport environments, including land, sea, air, and space. The recent introduction of new visual technologies may expose more of the population to visually induced motion sickness. This chapter describes the signs and symptoms of motion sickness and different types of provocative stimuli. The "how" of motion sickness (i.e., the mechanism) is generally accepted to involve sensory conflict, for which the evidence is reviewed. New observations concern the identification of putative "sensory conflict" neurons and the underlying brain mechanisms. But what reason or purpose does motion sickness serve, if any? This is the "why" of motion sickness, which is analyzed from both evolutionary and nonfunctional maladaptive theoretic perspectives. Individual differences in susceptibility are great in the normal population and predictors are reviewed. Motion sickness susceptibility also varies dramatically between special groups of patients, including those with different types of vestibular disease and in migraineurs. Finally, the efficacy and relative advantages and disadvantages of various behavioral and pharmacologic countermeasures are evaluated. PMID:27638085

  12. Removal of motion artifacts originating from optode fluctuations during functional near-infrared spectroscopy measurements

    PubMed Central

    Yamada, Toru; Umeyama, Shinji; Ohashi, Mitsuo

    2015-01-01

    Functional near-infrared spectroscopy (fNIRS) has been increasingly utilized for detecting human cerebral activity in many disciplines because of the potential for less-restraining conditions. However, users often suffer from motion artifacts originating from optode fluctuation during task execution when the task includes motion. In such cases, the optode fluctuation induces changes both in the reflection by hair and in the transmission between the optode and scalp. If part of the reflected light is directly received by the detector optode (short-circuited light), it will contaminate the fNIRS signal. The transmittance change at the optode–scalp gap will also contaminate the signal. In this study, we proposed an optical model on the influence of optode fluctuation on the fNIRS signal and a method for removing the influence. The model revealed the following: (1) the received short-circuited light and the gap transmittance change generated a baseline change in the detected light intensity, and (2) the signal from the tissues was downscaled with increases in the receiving intensity of short-circuited light. To avoid erroneous detection of short-circuited light, we developed a method that optically eliminated hair-reflected light from the detection using linearly polarized light sources and an orthogonally polarized analyzer. The method was validated with an optical phantom possessing a haired surface. The optical absorbance change of a close source–detector (S-D) pair equipped with polarizers was very similar to that of distant S-D pairs, even though these optodes were artificially fluctuated. By combining the multidistance optode arrangement technique with the short-circuited light elimination method, the measurement could effectively eliminate motion artifacts originating from optode fluctuation. PMID:26713183

  13. Coherent control of atomic motion in an optical lattice for precise measurements of gravity

    NASA Astrophysics Data System (ADS)

    Tarallo, Marco; Alberti, Andrea; Poli, Nicola; Prevedelli, Marco; Wang, Fu-Yuan; Tino, Guglielmo

    2011-05-01

    Coherent control of atomic motion inside an optical lattice allows precise measurement of forces by means amplitude-modulation (AM) driven resonant tunneling. We report about the recently-performed high precision measurements of gravitational acceleration using ultracold strontium atoms trapped in an AM driven vertical optical lattice. We reached an uncertainty Δg / g ~10-7 by measuring at the 5th harmonic of the Bloch oscillation frequency. We analyzed the systematic effects induced by the trapping optical lattice, such as the intensity gradient and the lattice frequency-induced shift. We accurately measured the lattice frequency by means of an fiber link with a home-made frequency comb. The value of g obtained with this microscopic quantum system is consistent with the one we measured with a classical absolute gravimeter. Short-distance measurements of gravity near dielectric surfaces are discussed. These results prospect a new way to new tests of gravity at micrometer scale. A. Alberti et al., New J. Phys. 12, 065037 (2010).

  14. MEASUREMENT OF HYDROPEROXIDES DURING THE TEXAS 2000 AIR QUALITY STUDY.

    SciTech Connect

    ZHENG,J.; ALAOUIE,A.; WEINSTEIN-LLOYD,J.B.; SPRINGSTON,S.R.; NUNNERMACKER,L.J.; LEE,Y.N.; BRECHTEL,F.; KLEINMAN,L.; DAUM,P.

    2002-01-17

    Hydroperoxides are important atmospheric oxidants. They are responsible for most of the oxidation of aqueous-phase SO{sub 2} to sulfate in the northeastern United States, resulting in the formation of acid precipitation and visibility-reducing sulfate aerosol (Penkett et al., 1979; Lind et al., 1987; Madronich and Calvert, 1990; Tanner and Schorran, 1995). Atmospheric hydrogen peroxide (H{sub 2}O{sub 2} or HP) is produced by the self-reaction of hydroperoxyl radicals (HO{sub 2}); higher organic peroxides are produced by reaction of HO{sub 2} with alkylperoxyl radicals (RO{sub 2}). Peroxyl radicals, along with OH, are chain carriers in the complex photochemical process that produces tropospheric ozone. Thus, concentrations of peroxides and their free radical precursors depend on solar intensity and ambient concentrations of water vapor, ozone, NO{sub x} (NO + NO{sub 2}), and VOCs (volatile organic compounds). Several investigators have demonstrated that HP and hydroxymethyl hydroperoxide (HOCH2 OOH or HMHP) also may be formed when ozone reacts with alkenes in moist air (Becker et al., 1990; Hewitt and Kok, 1991; Gaeb et al., 1995). Peroxides are the expected sink for peroxyl radicals when concentrations of NO are low. Otherwise, these radicals react with NO to form NO{sub 2}. Under high NO{sub x} conditions, NO{sub z} (oxidation products of NO and NO{sub 2}) becomes the principal radical sink. Therefore, formation rates of peroxides relative to NO{sub z} provide information about the history of an air mass and the expected sensitivity of ozone production to reduced emissions (Kleinman et al., 1997; Sillman, 1995; 1997). Through photolysis and reaction with OH, peroxides also act as a radical source; thus, reliable peroxide measurements are necessary for calculating ozone production rates. In this paper, we will summarize peroxide observations at the Williams Tower, and aboard the U.S. Department of Energy G-1 research aircraft in Houston, TX, during August and

  15. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

    SciTech Connect

    Walker, Iain; Stratton, Chris

    2015-07-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent).

  16. The Effective Mass of a Ball in the Air

    ERIC Educational Resources Information Center

    Messer, J.; Pantaleone, J.

    2010-01-01

    The air surrounding a projectile affects the projectile's motion in three very different ways: the drag force, the buoyant force, and the added mass. The added mass is an increase in the projectile's inertia from the motion of the air around it. Here we experimentally measure the added mass of a spherical projectile in air. The results agree well…

  17. Quantifying the Consistency of Wearable Knee Acoustical Emission Measurements During Complex Motions.

    PubMed

    Toreyin, Hakan; Jeong, Hyeon Ki; Hersek, Sinan; Teague, Caitlin N; Inan, Omer T

    2016-09-01

    Knee-joint sounds could potentially be used to noninvasively probe the physical and/or physiological changes in the knee associated with rehabilitation following acute injury. In this paper, a system and methods for investigating the consistency of knee-joint sounds during complex motions in silent and loud background settings are presented. The wearable hardware component of the system consists of a microelectromechanical systems microphone and inertial rate sensors interfaced with a field programmable gate array-based real-time processor to capture knee-joint sound and angle information during three types of motion: flexion-extension (FE), sit-to-stand (SS), and walking (W) tasks. The data were post-processed to extract high-frequency and short-duration joint sounds (clicks) with particular waveform signatures. Such clicks were extracted in the presence of three different sources of interference: background, stepping, and rubbing noise. A histogram-vector Vn(→) was generated from the clicks in a motion-cycle n, where the bin range was 10°. The Euclidean distance between a vector and the arithmetic mean Vav(→) of all vectors in a recording normalized by the Vav(→) is used as a consistency metric dn. Measurements from eight healthy subjects performing FE, SS, and W show that the mean (of mean) consistency metric for all subjects during SS (μ [ μ (dn)] = 0.72 in silent, 0.85 in loud) is smaller compared with the FE (μ [ μ (dn)] = 1.02 in silent, 0.95 in loud) and W ( μ [ μ (dn)] = 0.94 in silent, 0.97 in loud) exercises, thereby implying more consistent click-generation during SS compared with the FE and W. Knee-joint sounds from one subject performing FE during five consecutive work-days (μ [ μ (dn) = 0.72) and five different times of a day (μ [ μ (dn) = 0.73) suggests high consistency of the clicks on different days and throughout a day. This work represents the first time, to the best of our knowledge, that joint sound consistency has been

  18. Multi-temporal InSAR measurement of interseimic motion on the eastern Tibet border

    NASA Astrophysics Data System (ADS)

    Doin, M. P.; Lasserre, C.; He, P.; de Sigoyer, J.

    2014-12-01

    We use here SAR interferometry using archived Envisat data to map the interseismic deformation of eastern Tibet. The area under study starts just South of the Haiyuan fault, crosses the eastern termination of the Kunlun fault and the bend on the XianShuiHe fault to the South. It includes the Longriba fault system, an active structure located 150 km west of the Longmen Shan front (Xu et al., 2008, Ren et al., 2013). GPS data suggest that it may accommodate a large part of the present-day relative movement (6-8 mm/yr) between the Aba block and the south China block (Thatcher, 2007, Shen et al 2005). The Longriba and the Longmen Shan faults might be linked at depth by a decollement zone or by ductile shear in the crust (Shu et al., 2008). We process three adjacent Envisat 1000 km long swaths crossing this mountainous and vegetated terrain using a small baseline strategy. The interferograms show numerous phase perturbations that mask the interseismic motion due to : (1) coherence loss, (2) stratified atmospheric delays, (3) DEM error contribution, (4) the 2008 Sichuan earthquake. We will show how we tackle these limitations and display the effect of successive corrections. Focus will first be brought to the corrections applied before filtering and unwrapping, that increase phase spatial continuity. We estimate empirically stratified atmospheric delay polynomial relationship, depending on azimuth and elevation, on wrapped interferograms. We then estimate the local DEM error for each pixel. Multi-looking and filtering are based on various measures of pixel reliability in order to increase the signal to noise ratio of filtered interferograms. Finally, unwrapping is obtained by a region growing algorithm, from the most reliable areas to the least, avoiding to cross layover areas. Time series of phase delay maps in the Longriba area are dominated by a side lobe of the May 2008 Sichuan earthquake. After its extraction and correction, principal component analysis clearly

  19. Calibration of a Hall effect displacement measurement system for complex motion analysis using a neural network.

    PubMed

    Northey, G W; Oliver, M L; Rittenhouse, D M

    2006-01-01

    Biomechanics studies often require the analysis of position and orientation. Although a variety of transducer and camera systems can be utilized, a common inexpensive alternative is the Hall effect sensor. Hall effect sensors have been used extensively for one-dimensional position analysis but their non-linear behavior and cross-talk effects make them difficult to calibrate for effective and accurate two- and three-dimensional position and orientation analysis. The aim of this study was to develop and calibrate a displacement measurement system for a hydraulic-actuation joystick used for repetitive motion analysis of heavy equipment operators. The system utilizes an array of four Hall effect sensors that are all active during any joystick movement. This built-in redundancy allows the calibration to utilize fully connected feed forward neural networks in conjunction with a Microscribe 3D digitizer. A fully connected feed forward neural network with one hidden layer containing five neurons was developed. Results indicate that the ability of the neural network to accurately predict the x, y and z coordinates of the joystick handle was good with r(2) values of 0.98 and higher. The calibration technique was found to be equally as accurate when used on data collected 5 days after the initial calibration, indicating the system is robust and stable enough to not require calibration every time the joystick is used. This calibration system allowed an infinite number of joystick orientations and positions to be found within the range of joystick motion.

  20. Kinematics differences between the flat, kick, and slice serves measured using a markerless motion capture method.

    PubMed

    Sheets, Alison L; Abrams, Geoffrey D; Corazza, Stefano; Safran, Marc R; Andriacchi, Thomas P

    2011-12-01

    Tennis injuries have been associated with serving mechanics, but quantitative kinematic measurements in realistic environments are limited by current motion capture technologies. This study tested for kinematic differences at the lower back, shoulder, elbow, wrist, and racquet between the flat, kick, and slice serves using a markerless motion capture (MMC) system. Seven male NCAA Division 1 players were tested on an outdoor court in daylight conditions. Peak racquet and joint center speeds occurred sequentially and increased from proximal (back) to distal (racquet). Racquet speeds at ball impact were not significantly different between serve types. However, there were significant differences in the direction of the racquet velocity vector between serves: the kick serve had the largest lateral and smallest forward racquet velocity components, while the flat serve had the smallest vertical component (p < 0.01). The slice serve had lateral velocity, like the kick, and large forward velocity, like the flat. Additionally, the racquet in the kick serve was positioned 8.7 cm more posterior and 21.1 cm more medial than the shoulder compared with the flat, which could suggest an increased risk of shoulder and back injury associated with the kick serve. This study demonstrated the potential for MMC for testing sports performance under natural conditions. PMID:21984513

  1. OPTICAL PROPER MOTION MEASUREMENTS OF THE M87 JET: NEW RESULTS FROM THE HUBBLE SPACE TELESCOPE

    SciTech Connect

    Meyer, Eileen T.; Sparks, W. B.; Biretta, J. A.; Anderson, Jay; Sohn, Sangmo Tony; Van der Marel, Roeland P.; Norman, Colin; Nakamura, Masanori

    2013-09-10

    We report new results from a Hubble Space Telescope archival program to study proper motions in the optical jet of the nearby radio galaxy M87. Using over 13 yr of archival imaging, we reach accuracies below 0.1c in measuring the apparent velocities of individual knots in the jet. We confirm previous findings of speeds up to 4.5c in the inner 6'' of the jet, and report new speeds for optical components in the outer part of the jet. We find evidence of significant motion transverse to the jet axis on the order of 0.6c in the inner jet features, and superluminal velocities parallel and transverse to the jet in the outer knot components, with an apparent ordering of velocity vectors possibly consistent with a helical jet pattern. Previous results suggested a global deceleration over the length of the jet in the form of decreasing maximum speeds of knot components from HST-1 outward, but our results suggest that superluminal speeds persist out to knot C, with large differentials in very nearby features all along the jet. We find significant apparent accelerations in directions parallel and transverse to the jet axis, along with evidence for stationary features in knots D, E, and I. These results are expected to place important constraints on detailed models of kiloparsec-scale relativistic jets.

  2. Proper Motions of Dwarf Spheroidal Galaxies from Hubble Space Telescope Imaging. 3; Measurement for URSA Minor

    NASA Technical Reports Server (NTRS)

    Piatek, Slawomir; Pryor, Carlton; Bristow, Paul; Olszewski, Edward W.; Harris, Hugh C.; Mateo, Mario; Minniti, Dante; Tinney, Christopher G.

    2005-01-01

    This article presents a measurement of the proper motion of the Ursa Minor dwarf spheroidal galaxy determined from images taken with the Hubble Space Telescope in two distinct fields. Each field contains a quasi-stellar object that serves as the "reference point". Integrating the motion of Ursa Minor in a realistic potential for the Milky Way produces orbital elements. The perigalacticon and apogalacticon are 40 (10, 76) and 89 (78, 160) kpc, respectively, where the values in the parentheses represent the 95% confidence intervals derived from Monte Carlo experiments. The eccentricity of the orbit is 0.39 (0.09, 0.79), and the orbital period is 1.5 (1.1, 2.7) Gyr. The orbit is retrograde and inclined by 124 degrees (94 deg, 36 deg ) to the Galactic plane. Ursa Minor is not a likely member of a proposed stream of galaxies on similar orbits around the Milky Way, nor is the plane of its orbit coincident with a recently proposed planar alignment of galaxies around the Milky Way. Comparing the orbits of Ursa Minor and Carina shows no reason for the different star formation histories of these two galaxies. Ursa Minor must contain dark matter to have a high probability of having survived disruption by the Galactic tidal force until the present.

  3. "New Proper Motion Measurements of the Superluminal Velocities in the M87 Optical Jet with HST"

    NASA Astrophysics Data System (ADS)

    Meyer, Eileen T.; Sparks, W. B.; Biretta, J. A.; Sohn, S.; Anderson, J.; Van Der Marel, R. P.; Norman, C. A.; Nakamura, M.

    2014-01-01

    Using over 13 years of archival HST observations of the relativistic jet in the archetypal radio galaxy M87, we have produced astrometric speed measurements of the optically bright synchrotron emitting plasma components in the jet with unprecedented accuracy. Building on previous work showing the superluminal nature of the jet in the optical, we have found that the jet motion is incredibly complex, with both transverse motions and flux variations which can be seen very clearly by eye in the timeseries of deep exposures. These observations of M87 provide us with a unique dataset with which to refine theoretical models of the largescale jet structure, potentially addressing open questions such as the jet collimation mechanism, bulk acceleration and deceleration in the jet, and the presence of a helical structure. I will also present very recent results using data from the HST archive on the optical counterjet and nuclear regions of M87 and discuss the larger implications of these detailed studies of one of the most nearby AGN jets.

  4. In vivo motion and force measurement of surgical needle intervention during prostate brachytherapy

    SciTech Connect

    Podder, Tarun; Clark, Douglas; Sherman, Jason; Fuller, Dave; Messing, Edward; Rubens, Deborah; Strang, John; Brasacchio, Ralph; Liao, Lydia; Ng, W.-S.; Yu Yan

    2006-08-15

    In this paper, we present needle insertion forces and motion trajectories measured during actual brachytherapy needle insertion while implanting radioactive seeds in the prostate glands of 20 different patients. The needle motion was captured using ultrasound images and a 6 degree-of-freedom electromagnetic-based position sensor. Needle velocity was computed from the position information and the corresponding time stamps. From in vivo data we found the maximum needle insertion forces to be about 15.6 and 8.9 N for 17 gauge (1.47 mm) and 18 gauge (1.27 mm) needles, respectively. Part of this difference in insertion forces is due to the needle size difference (17G and 18G) and the other part is due to the difference in tissue properties that are specific to the individual patient. Some transverse forces were observed, which are attributed to several factors such as tissue heterogeneity, organ movement, human factors in surgery, and the interaction between the template and the needle. However, theses insertion forces are significantly responsible for needle deviation from the desired trajectory and target movement. Therefore, a proper selection of needle and modulated velocity (translational and rotational) may reduce the tissue deformation and target movement by reducing insertion forces and thereby improve the seed delivery accuracy. The knowledge gleaned from this study promises to be useful for not only designing mechanical/robotic systems but also developing a predictive deformation model of the prostate and real-time adaptive controlling of the needle.

  5. Motion artifact removal algorithm by ICA for e-bra: a women ECG measurement system

    NASA Astrophysics Data System (ADS)

    Kwon, Hyeokjun; Oh, Sechang; Varadan, Vijay K.

    2013-04-01

    Wearable ECG(ElectroCardioGram) measurement systems have increasingly been developing for people who suffer from CVD(CardioVascular Disease) and have very active lifestyles. Especially, in the case of female CVD patients, several abnormal CVD symptoms are accompanied with CVDs. Therefore, monitoring women's ECG signal is a significant diagnostic method to prevent from sudden heart attack. The E-bra ECG measurement system from our previous work provides more convenient option for women than Holter monitor system. The e-bra system was developed with a motion artifact removal algorithm by using an adaptive filter with LMS(least mean square) and a wandering noise baseline detection algorithm. In this paper, ICA(independent component analysis) algorithms are suggested to remove motion artifact factor for the e-bra system. Firstly, the ICA algorithms are developed with two kinds of statistical theories: Kurtosis, Endropy and evaluated by performing simulations with a ECG signal created by sgolayfilt function of MATLAB, a noise signal including 0.4Hz, 1.1Hz and 1.9Hz, and a weighed vector W estimated by kurtosis or entropy. A correlation value is shown as the degree of similarity between the created ECG signal and the estimated new ECG signal. In the real time E-Bra system, two pseudo signals are extracted by multiplying with a random weighted vector W, the measured ECG signal from E-bra system, and the noise component signal by noise extraction algorithm from our previous work. The suggested ICA algorithm basing on kurtosis or entropy is used to estimate the new ECG signal Y without noise component.

  6. Motion as a perturbation: Measurement-guided dose estimates to moving patient voxels during modulated arc deliveries

    SciTech Connect

    Feygelman, Vladimir; Zhang, Geoffrey; Hunt, Dylan; Opp, Daniel; Stambaugh, Cassandra; Wolf, Theresa K.; Nelms, Benjamin E.

    2013-02-15

    Purpose: To present a framework for measurement-guided VMAT dose reconstruction to moving patient voxels from a known motion kernel and the static phantom data, and to validate this perturbation-based approach with the proof-of-principle experiments. Methods: As described previously, the VMAT 3D dose to a static patient can be estimated by applying a phantom measurement-guided perturbation to the treatment planning system (TPS)-calculated dose grid. The fraction dose to any voxel in the presence of motion, assuming the motion kernel is known, can be derived in a similar fashion by applying a measurement-guided motion perturbation. The dose to the diodes in a helical phantom is recorded at 50 ms intervals and is transformed into a series of time-resolved high-density volumetric dose grids. A moving voxel is propagated through this 4D dose space and the fraction dose to that voxel in the phantom is accumulated. The ratio of this motion-perturbed, reconstructed dose to the TPS dose in the phantom serves as a perturbation factor, applied to the TPS fraction dose to the similarly situated voxel in the patient. This approach was validated by the ion chamber and film measurements on four phantoms of different shape and structure: homogeneous and inhomogeneous cylinders, a homogeneous cube, and an anthropomorphic thoracic phantom. A 2D motion stage was used to simulate the motion. The stage position was synchronized with the beam start time with the respiratory gating simulator. The motion patterns were designed such that the motion speed was in the upper range of the expected tumor motion (1-1.4 cm/s) and the range exceeded the normally observed limits (up to 5.7 cm). The conformal arc plans for X or Y motion (in the IEC 61217 coordinate system) consisted of manually created narrow (3 cm) rectangular strips moving in-phase (tracking) or phase-shifted by 90 Degree-Sign (crossing) with respect to the phantom motion. The XY motion was tested with the computer-derived VMAT

  7. Six Degrees-of-Freedom Prostate and Lung Tumor Motion Measurements Using Kilovoltage Intrafraction Monitoring

    SciTech Connect

    Huang, Chen-Yu; Tehrani, Joubin Nasehi; Ng, Jin Aun; Booth, Jeremy; Keall, Paul

    2015-02-01

    Purpose: Tumor positional uncertainty has been identified as a major issue that deteriorates the efficacy of radiation therapy. Tumor rotational movement, which is not well understood, can result in significant geometric and dosimetric inaccuracies. The objective of this study was to measure 6 degrees-of-freedom (6 DoF) prostate and lung tumor motion, focusing on the more novel rotation, using kilovoltage intrafraction monitoring (KIM). Methods and Materials: Continuous kilovoltage (kV) projections of tumors with gold fiducial markers were acquired during radiation therapy for 267 fractions from 10 prostate cancer patients and immediately before or after radiation therapy for 50 fractions from 3 lung cancer patients. The 6 DoF motion measurements were determined from the individual 3-dimensional (3D) marker positions, after using methods to reject spurious and smooth noisy data, using an iterative closest point algorithm. Results: There were large variations in the magnitude of the tumor rotation among different fractions and patients. Various rotational patterns were observed. The average prostate rotation angles around the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) axes were 1.0 ± 5.0°, 0.6 ± 3.3°, and 0.3 ± 2.0°, respectively. For 35% of the time, the prostate rotated more than 5° about the LR axis, indicating the need for intrafractional adaptation during radiation delivery. For lung patients, the average LR, SI, and AP rotation angles were 0.8 ± 4.2°, −0.8 ± 4.5°, and 1.7 ± 3.1°, respectively. For about 30% of the time, the lung tumors rotated more than 5° around the SI axis. Respiration-induced rotation was detected in 2 of the 3 lung patients. Conclusions: The prostate and lung tumors were found to undergo rotations of more than 5° for about a third of the time. The lung tumor data represent the first 6 DoF tumor motion measured by kV images. The 6 DoF KIM method can enable rotational and translational

  8. Comparisons of Air Radiation Model with Shock Tube Measurements

    NASA Technical Reports Server (NTRS)

    Bose, Deepak; McCorkle, Evan; Bogdanoff, David W.; Allen, Gary A., Jr.

    2009-01-01

    This paper presents an assessment of the predictive capability of shock layer radiation model appropriate for NASA s Orion Crew Exploration Vehicle lunar return entry. A detailed set of spectrally resolved radiation intensity comparisons are made with recently conducted tests in the Electric Arc Shock Tube (EAST) facility at NASA Ames Research Center. The spectral range spanned from vacuum ultraviolet wavelength of 115 nm to infrared wavelength of 1400 nm. The analysis is done for 9.5-10.5 km/s shock passing through room temperature synthetic air at 0.2, 0.3 and 0.7 Torr. The comparisons between model and measurements show discrepancies in the level of background continuum radiation and intensities of atomic lines. Impurities in the EAST facility in the form of carbon bearing species are also modeled to estimate the level of contaminants and their impact on the comparisons. The discrepancies, although large is some cases, exhibit order and consistency. A set of tests and analyses improvements are proposed as forward work plan in order to confirm or reject various proposed reasons for the observed discrepancies.

  9. Demonstrations of Magnetic Phenomena: Measuring the Air Permeability Using Tablets

    ERIC Educational Resources Information Center

    Lara, V. O. M.; Amaral, D. F.; Faria, D.; Vieira, L. P.

    2014-01-01

    We use a tablet to experimentally determine the dependencies of the magnetic field (B) on the electrical current and the axial distance from a coil (z). Our data shows good precision on the inverse cubic dependence of the magnetic field on the axial distance, B?z[superscript -3]. We obtain the value of air permeability µ[subscript air] with good…

  10. Airborne Measurements of Trace Gases and Aerosols in Northern China: EAST-AIRE IOP 2005

    NASA Astrophysics Data System (ADS)

    Li, C.; Dickerson, R. R.; Li, Z.; Stehr, J. W.; Chen, H.; Marufu, L. T.

    2005-12-01

    To characterize the emission, transport and removal of pollutants and aerosols emitted from East Asia, a US-China joint field campaign was conducted from February to April in China under the EAST-AIRE project. Surface and airborne measurements of trace gases and aerosols were made at different locations in northern China. In early April, eight research flights were conducted around Shenyang, an industrialized city with a population of about 6 million, 600 km northeast of Beijing. Parameters measured include SO2, CO, O3, aerosol size distribution, aerosol scattering and absorption coefficients. During 4 of the 8 flights, the research aircraft made spirals over two suburban locations (~50 km south and north of the downtown area of Shenyang) to determine the detailed vertical distribution of trace gases and aerosols. Various weather patterns were encountered, allowing an examination of the roles of atmospheric circulation in transporting local pollutants to much larger areas. For example, the flights made ahead of the cold front showed fairly high concentrations of pollutants above the planetary boundary layer, probably lifted by the upward motion associated with the approaching cold fronts. On the other hand, much lower pollutant levels were found for the flights made behind the cold front. Also observed in one cold-sector flight is a level (~3000 m) with enhanced aerosol scattering but almost undetectable SO2. Back trajectory analysis using NOAA-HYSPLIT model suggests possible dust transport from source regions.

  11. Combination of Insar and GPS to Measure Ground Motions and Atmospheric Signals

    NASA Astrophysics Data System (ADS)

    Zerbini, S.; Prati, C.; Errico, M.; Ferri, S.; Novali, F.; Scirpoli, S.; Tiberi, L.

    2010-12-01

    The combination of different techniques such as InSAR and GPS is characterized by the added value of taking advantage of their complementary strengths and of minimizing their respective weaknesses, thus allowing for the full exploitation of the complementary aspects by overcoming the limitations inherent in the use of each technique alone. Another important aspect of the GPS/InSAR integration regards the fact that today’s application of interferometric SAR techniques is limited by the knowledge of the wet tropospheric path delay in microwave observations. GPS-based estimates of tropospheric delays may help in obtaining better corrections which will enhance the coherence and will allow the application of InSAR in a wider range of applications. The area selected for the InSAR/GPS comparison/integration is in northeastern Italy and includes the town of Bologna, and two nearby sites Medicina (agricultural area) and Loiano (a small city on the Apennines) where a small network of permanent GPS stations is operated by the University of Bologna. The InSAR data used are the COSMO-SkyMed (CSK) images made available by the Italian Space Agency (ASI) in the framework of the research contract AO-1140. The Permanent Scatterers (PS) technique will be applied to a number of repeated CSK strip map SAR images acquired over a 40x40 square km area encompassing the towns mentioned above. Ultimately this work will contribute demonstrating the CSK capabilities to operate in a repeated interferometric survey mode for measuring ground deformation with millimeter accuracy in different environments. A PS is a target whose radar signature is stable with time. Such targets can be identified by means of multiple SAR observations and they can be exploited for jointly estimating their relative motion and the atmospheric artifacts on a grid that can be quite dense in space but not in time (depending on the SAR revisiting time interval). On the contrary the GPS can provide very frequent time

  12. Measurement of velocity and vorticity fields in the wake of an airfoil in periodic pitching motion

    NASA Technical Reports Server (NTRS)

    Booth, Earl R., Jr.

    1987-01-01

    The velocity field created by the wake of an airfoil undergoing a prescribed pitching motion was sampled using hot wire anemometry. Data analysis methods concerning resolution of velocity components from cross wire data, computation of vorticity from velocity time history data, and calculation of vortex circulation from vorticity field data are discussed. These data analysis methods are applied to a flow field relevant to a two dimensional blade-vortex interaction study. Velocity time history data were differentiated to yield vorticity field data which are used to characterize the wake of the pitching airfoil. Measurement of vortex strength in sinusoidal and nonsinusoidal wakes show vortices in the sinusoidal wake have stronger circulation and more concentrated vorticity distributions than the tailored nonsinusoidal wake.

  13. 3-dimentional measurement of cable configuration being based on feature tracking motion stereo

    NASA Astrophysics Data System (ADS)

    Domae, Yukiyasu; Okuda, Haruhisa; Takauji, Hidenori; Kaneko, Shun'ichi; Tanaka, Takayuki

    2007-10-01

    We propose a novel three-Dimensional measurement approach of flexible cables for factory automation appliations, such as cable handling, connecter insertion without conflicts with cables by using robotic arms. The approach is based on motion stereo with a vision sensor. Laser slit beams are irradiated and make landmalks on the cables to solve stereo correspondence problem efficiently. These landmark points and interpolated points having rich texture are tracked in a image sequence, and reconstructed as the cable shape. For stable feature point tracking, a robust texture matching method which is Orientation Code Matching and tracking stability analysis are applied. In our experiments, arch-like cables have been reconstructed with an uncertainty of 1.5 % by this method.

  14. Large band high sensitivity motion measurement and control of spacecrafts and satellites

    NASA Astrophysics Data System (ADS)

    Barone, F.; Giordano, G.; Acernese, F.; Romano, R.

    2016-04-01

    In this paper we describe the characteristics and performances of mono-axial monolithic sensors aimed to low frequency motion measurement and control of spacecrafts and satellites. The mechanical part of these sensors is based on the UNISA Folded Pendulum, a mechanical architecture developed for ground-based applications. The unique features of the UNISA class of folded pendulum sensors (compactness, lightness, scalability, low resonance frequency and high quality factor) are based on the action of the gravitational force on the the moving part of the sensor. In this paper we show how to extend the application of ground-based folded pendulum also to space, in absence of gravity, still keeping all their peculiar features and characteristics. Tests on a prototype confirm the feasibility of this application, demonstrating also that interesting performances can be relatively easily obtained.

  15. Current Arabian Plate Motion From Campaign GPS Measurements in Saudi Arabia: Preliminary Results

    NASA Astrophysics Data System (ADS)

    Almuslmani, B.; Teferle, F. N.; Bingley, R. M.; Moore, T.

    2007-12-01

    Current investigations of the motions of the Arabian and its neighboring plates are primarily based on GPS measurements obtained in the surrounding areas of the Arabian plate, with few stations actually located on the Arabian plate itself in the Kingdom of Saudi Arabia. In order to advance the knowledge of the dynamics of the Arabian plate and its intra-plate deformations, the General Directorate of Military Survey (GDMS), through collaboration with the Institute of Engineering Surveying and Space Geodesy (IESSG), densified the GPS network in Saudi Arabia, covering nearly two thirds of the tectonic plate. Since July 2002, a network of 32 GPS stations has been established at locations of the Saudi Arabia geodetic network. At all of these GPS stations a concrete pillar has been used as the monument and the locations have been selected in order to give the broadest distribution of observing sites. During 2005, 27 additional GPS stations in the Hejaz and Asser Mountains, and the Farasan Islands, all in south-western Saudi Arabia, have been established, for which the past and future campaign GPS measurements will provide valuable data for investigations of crustal deformations close to the plate boundaries between the Nubia, Somalian and Arabian plates. In this presentation we will show results in the form of velocity field and plate motion estimates based on data from at least three campaigns occupying the initial 32 GDMS GPS network stations, but also from a number of IGS stations in the region. Our reference frame is aligned to ITRF2005 and uses approximately 40 IGS reference frame stations located on all major tectonic plates, e.g. Nubia and Somalia, surrounding the Arabian plate. Furthermore, we apply absolute satellite and receiver antenna phase center models together with newly available GPS products from a recent global re-processing effort.

  16. Motional induction voltage measurements in estuarine environments: the Ria de Aveiro Lagoon (Portugal)

    NASA Astrophysics Data System (ADS)

    Nolasco, Rita; Soares, António; Dias, João M.; Monteiro Santos, Fernando A.; Palshin, N. A.; Represas, Patricia; Vaz, Nuno

    2006-07-01

    Electromagnetic fluctuations in the ocean have external sources like ionospheric-magnetospheric current systems, and purely internal oceanic sources associated with interaction between water velocity fields and the geomagnetic field, that is, the motionally induced voltage (MIV). During the last decade techniques based on MIV have proven to provide reliable information when applied to the flow monitoring at large oceanic channels. In this paper analysis of data resulting from the implementation of these techniques in a small-scale system, that is, the Ria de Aveiro lagoon (Portugal), is presented. A submarine cable crossing the channel at the entrance of the lagoon (Barra channel) allows the measurement of the potential difference between two electrodes located on both sides of the channel. Spectral analysis of these data reveals that measured voltages are dominated by semidiurnal M2, S2/K2 frequencies. Comparison between the sum of the four main constituents determined by harmonic analysis and the sea surface elevation measured at a tide gauge located at the lagoon mouth reveal that the measured potential difference is proportional to the water flow. To estimate the water flow in this location from the MIV measurements the data collected using this methodology were compared with numerical results obtained from a previously calibrated hydrodynamic model. A value of 720 m3 s-1 mV-1 was estimated for the coefficient relating voltage and water transport at Barra. Taking this value into account a sediment layer of about 20 m is estimated, at Barra. The results show that it is possible to indirectly measure the water transport (by tidal and residual flows) through the channel by measuring the differences of electrical potential. This demonstrates the applicability of the MIV method to a small-scale system.

  17. Clinical measures of hip and foot-ankle mechanics as predictors of rearfoot motion and posture.

    PubMed

    Souza, Thales R; Mancini, Marisa C; Araújo, Vanessa L; Carvalhais, Viviane O C; Ocarino, Juliana M; Silva, Paula L; Fonseca, Sérgio T

    2014-10-01

    Health professionals are frequently interested in predicting rearfoot pronation during weight-bearing activities. Previous inconsistent results regarding the ability of clinical measures to predict rearfoot kinematics may have been influenced by the neglect of possible combined effects of alignment and mobility at the foot-ankle complex and by the disregard of possible influences of hip mobility on foot kinematics. The present study tested whether using a measure that combines frontal-plane bone alignment and mobility at the foot-ankle complex and a measure of hip internal rotation mobility predicts rearfoot kinematics, in walking and upright stance. Twenty-three healthy subjects underwent assessment of forefoot-shank angle (which combines varus bone alignments at the foot-ankle complex with inversion mobility at the midfoot joints), with a goniometer, and hip internal rotation mobility, with an inclinometer. Frontal-plane kinematics of the rearfoot was assessed with a three-dimensional system, during treadmill walking and upright stance. Multivariate linear regressions tested the predictive strength of these measures to inform about rearfoot kinematics. The measures significantly predicted (p ≤ 0.041) mean eversion-inversion position, during walking (r(2) = 0.40) and standing (r(2) = 0.31), and eversion peak in walking (r(2) = 0.27). Greater values of varus alignment at the foot-ankle complex combined with inversion mobility at the midfoot joints and greater hip internal rotation mobility are related to greater weight-bearing rearfoot eversion. Each measure (forefoot-shank angle and hip internal rotation mobility) alone and their combination partially predicted rearfoot kinematics. These measures may help detecting foot-ankle and hip mechanical variables possibly involved in an observed rearfoot motion or posture.

  18. Demonstrations of magnetic phenomena: measuring the air permeability using tablets

    NASA Astrophysics Data System (ADS)

    Lara, V. O. M.; Amaral, D. F.; Faria, D.; Vieira, L. P.

    2014-11-01

    We use a tablet to experimentally determine the dependencies of the magnetic field (B) on the electrical current and the axial distance from a coil (z). Our data shows good precision on the inverse cubic dependence of the magnetic field on the axial distance, B ∝ z-3. We obtain the value of air permeability μair with good accuracy. We also observe the same dependence of B on z when considering a magnet instead of a coil. Although our estimates are obtained through simple data fits, we also perform a more sophisticated error analysis, confirming the result for μair.

  19. Measurement of solids motion in gas-fluidized beds. Technical progress report, 1 October 1982-31 December 1982

    SciTech Connect

    Chen, M.M.; Chao, B.T.

    1982-01-01

    This technical progress report covers the progress made during the fifth quarter of the project entitled Measurements of Solids Motion in Gas Fluidized Beds under Grant No. DOE-F22-81PC40804 during the period 1 October through 31 December 1982. The research concerns the measurement of solids particle velocity distribution and residence time distribution using the Computer-Aided Particle Tracking Facility (CAPTF) at the University of Illinois at Urbana-Champaign. The experimental equipment and measuring methods used to determine particle size distribution and particle motion and the results obtained are presented.

  20. THE M31 VELOCITY VECTOR. I. HUBBLE SPACE TELESCOPE PROPER-MOTION MEASUREMENTS

    SciTech Connect

    Sohn, Sangmo Tony; Anderson, Jay; Van der Marel, Roeland P.

    2012-07-01

    We present the first proper-motion (PM) measurements for the galaxy M31. We obtained new V-band imaging data with the Hubble Space Telescope ACS/WFC and the WFC3/UVIS instruments of three fields: a spheroid field near the minor axis, an outer disk field along the major axis, and a field on the Giant Southern Stream. The data provide five to seven year time baselines with respect to pre-existing deep first-epoch observations of the same fields. We measure the positions of thousands of M31 stars and hundreds of compact background galaxies in each field. High accuracy and robustness is achieved by building and fitting a unique template for each individual object. The average PM for each field is obtained from the average motion of the M31 stars between the epochs with respect to the background galaxies. For the three fields, the observed PMs ({mu}{sub W}, {mu}{sub N}) are, in units of mas yr{sup -1}, (- 0.0458, -0.0376) {+-} (0.0165, 0.0154), (- 0.0533, -0.0104) {+-} (0.0246, 0.0244), and (- 0.0179, -0.0357) {+-} (0.0278, 0.0272), respectively. The ability to average over large numbers of objects and over the three fields yields a final displacement accuracy of a few thousandths of a pixel, corresponding to only 12 {mu}as yr{sup -1}. This is comparable to what has been achieved for other Local Group galaxies using Very Long Baseline Array observations of water masers. Potential systematic errors are controlled by an analysis strategy that corrects for detector charge transfer inefficiency, spatially and time-dependent geometric distortion, and point-spread function variations. The robustness of the PM measurements and uncertainties are supported by the fact that data from different instruments, taken at different times and with different telescope orientations, as well as measurements of different fields, all yield statistically consistent results. Papers II and III of this series explore the implications of the new measurements for our understanding of the history

  1. Real-Time Aerodynamic Parameter Estimation without Air Flow Angle Measurements

    NASA Technical Reports Server (NTRS)

    Morelli, Eugene A.

    2010-01-01

    A technique for estimating aerodynamic parameters in real time from flight data without air flow angle measurements is described and demonstrated. The method is applied to simulated F-16 data, and to flight data from a subscale jet transport aircraft. Modeling results obtained with the new approach using flight data without air flow angle measurements were compared to modeling results computed conventionally using flight data that included air flow angle measurements. Comparisons demonstrated that the new technique can provide accurate aerodynamic modeling results without air flow angle measurements, which are often difficult and expensive to obtain. Implications for efficient flight testing and flight safety are discussed.

  2. Development of a 6-DoF motion system for realizing a linear datum for geometric measurements.

    PubMed

    Wang, Shaokai; Cui, Jiwen; Tan, Jiubin; Liu, Yongmeng

    2016-08-01

    In order to further improve the linear datum based geometric measurement accuracy and expand the measurement range, a 6-DoF motion system is developed for realizing a linear datum in the form of motion trajectory of the contact point (CP) of an absolute displacement measurement probe. This linear datum is established based on the concept of coordinate measurement and it does not contain straightness error in theory. The 6-DoF motion system consists of a 6-DoF fine stage and a 1-DoF coarse stage. The probe is moved by the 6-DoF fine stage which is magnetically noncontact supported and parallelly noncontact actuated. A CP-centred 6-DoF metrology model and a CP-centred 6-DoF motion model are established for elimination of Abbe error and on-line compensation of motion error of CP, respectively. 1-DoF coarse stage is controlled with relative position between two stages to extend the limited motion range of 6-DoF fine stage along the linear datum. Effectiveness of the metrology and motion models is verified through experiment. Straightness error of a 91.5 mm long line of an optical flat is measured by the proposed system and a commercial Fizeau interferometer. Comparison shows a consistency with standard deviation of 11 nm. Another experiment indicates that the proposed system could be used to realize a linear datum within a range of 220 mm with a repeatability of standard deviation of 7 nm. PMID:27587168

  3. Development of a 6-DoF motion system for realizing a linear datum for geometric measurements

    NASA Astrophysics Data System (ADS)

    Wang, Shaokai; Cui, Jiwen; Tan, Jiubin; Liu, Yongmeng

    2016-08-01

    In order to further improve the linear datum based geometric measurement accuracy and expand the measurement range, a 6-DoF motion system is developed for realizing a linear datum in the form of motion trajectory of the contact point (CP) of an absolute displacement measurement probe. This linear datum is established based on the concept of coordinate measurement and it does not contain straightness error in theory. The 6-DoF motion system consists of a 6-DoF fine stage and a 1-DoF coarse stage. The probe is moved by the 6-DoF fine stage which is magnetically noncontact supported and parallelly noncontact actuated. A CP-centred 6-DoF metrology model and a CP-centred 6-DoF motion model are established for elimination of Abbe error and on-line compensation of motion error of CP, respectively. 1-DoF coarse stage is controlled with relative position between two stages to extend the limited motion range of 6-DoF fine stage along the linear datum. Effectiveness of the metrology and motion models is verified through experiment. Straightness error of a 91.5 mm long line of an optical flat is measured by the proposed system and a commercial Fizeau interferometer. Comparison shows a consistency with standard deviation of 11 nm. Another experiment indicates that the proposed system could be used to realize a linear datum within a range of 220 mm with a repeatability of standard deviation of 7 nm.

  4. Development of a 6-DoF motion system for realizing a linear datum for geometric measurements.

    PubMed

    Wang, Shaokai; Cui, Jiwen; Tan, Jiubin; Liu, Yongmeng

    2016-08-01

    In order to further improve the linear datum based geometric measurement accuracy and expand the measurement range, a 6-DoF motion system is developed for realizing a linear datum in the form of motion trajectory of the contact point (CP) of an absolute displacement measurement probe. This linear datum is established based on the concept of coordinate measurement and it does not contain straightness error in theory. The 6-DoF motion system consists of a 6-DoF fine stage and a 1-DoF coarse stage. The probe is moved by the 6-DoF fine stage which is magnetically noncontact supported and parallelly noncontact actuated. A CP-centred 6-DoF metrology model and a CP-centred 6-DoF motion model are established for elimination of Abbe error and on-line compensation of motion error of CP, respectively. 1-DoF coarse stage is controlled with relative position between two stages to extend the limited motion range of 6-DoF fine stage along the linear datum. Effectiveness of the metrology and motion models is verified through experiment. Straightness error of a 91.5 mm long line of an optical flat is measured by the proposed system and a commercial Fizeau interferometer. Comparison shows a consistency with standard deviation of 11 nm. Another experiment indicates that the proposed system could be used to realize a linear datum within a range of 220 mm with a repeatability of standard deviation of 7 nm.

  5. A Conductivity Device for Measuring Sulfur Dioxide in the Air

    ERIC Educational Resources Information Center

    Craig, James C.

    1972-01-01

    Described is a general electroconductivity device enabling students to determine sulfur dioxide concentration in a particular location, hopefully leading to a deeper understanding of the problem of air pollution. (DF)

  6. Air Traffic Complexity Measurement Environment (ACME): Software User's Guide

    NASA Technical Reports Server (NTRS)

    1996-01-01

    A user's guide for the Air Traffic Complexity Measurement Environment (ACME) software is presented. The ACME consists of two major components, a complexity analysis tool and user interface. The Complexity Analysis Tool (CAT) analyzes complexity off-line, producing data files which may be examined interactively via the Complexity Data Analysis Tool (CDAT). The Complexity Analysis Tool is composed of three independently executing processes that communicate via PVM (Parallel Virtual Machine) and Unix sockets. The Runtime Data Management and Control process (RUNDMC) extracts flight plan and track information from a SAR input file, and sends the information to GARP (Generate Aircraft Routes Process) and CAT (Complexity Analysis Task). GARP in turn generates aircraft trajectories, which are utilized by CAT to calculate sector complexity. CAT writes flight plan, track and complexity data to an output file, which can be examined interactively. The Complexity Data Analysis Tool (CDAT) provides an interactive graphic environment for examining the complexity data produced by the Complexity Analysis Tool (CAT). CDAT can also play back track data extracted from System Analysis Recording (SAR) tapes. The CDAT user interface consists of a primary window, a controls window, and miscellaneous pop-ups. Aircraft track and position data is displayed in the main viewing area of the primary window. The controls window contains miscellaneous control and display items. Complexity data is displayed in pop-up windows. CDAT plays back sector complexity and aircraft track and position data as a function of time. Controls are provided to start and stop playback, adjust the playback rate, and reposition the display to a specified time.

  7. Effect of air on energy and rise-time spectra measured by proportional gas counter

    SciTech Connect

    Kawano, T.; Tanaka, M.; Isozumi, S.; Isozumi, Y.; Tosaki, M.; Sugiyama, T.

    2015-03-15

    Air exerts a negative effect on radiation detection using a gas counter because oxygen contained in air has a high electron attachment coefficient and can trap electrons from electron-ion pairs created by ionization from incident radiation in counting gas. This reduces radiation counts. The present study examined the influence of air on energy and rise-time spectra measurements using a proportional gas counter. In addition, a decompression procedure method was proposed to reduce the influence of air and its effectiveness was investigated. For the decompression procedure, the counting gas inside the gas counter was decompressed below atmospheric pressure before radiation detection. For the spectrum measurement, methane as well as various methane and air mixtures were used as the counting gas to determine the effect of air on energy and rise-time spectra. Results showed that the decompression procedure was effective for reducing or eliminating the influence of air on spectra measurement using a proportional gas counter. (authors)

  8. Note: Spectral motional Stark effect diagnostic for measurement of magnetic fields below 0.3 T

    NASA Astrophysics Data System (ADS)

    Lizunov, A.; Donin, A.; Savkin, V.

    2013-08-01

    The paper reports on development of the spectral motional Stark effect (MSE) diagnostic in the midplane of the gas dynamic trap (GDT) linear system for magnetic confinement of anisotropic hot-ion plasma. The axially symmetric GDT vacuum magnetic field has a minimum value in the midplane, which varies from 0.2 to 0.35 T in different regimes of operation. Buildup of 15 keV ion population generates a diamagnetic reduction of magnetic field in the plasma core of up to 30% in the maximum density region, as measured by the existing eight-line MSE diagnostic. Commissioning of the midplane MSE provided first direct measurements of diamagnetic modifications in the minimum magnetic field GDT section, a necessary complement to the understanding of equilibrium and self-organization of high-β plasmas in GDT. Making use of the stable short-pulse diagnostic beam and calibration of the apparent spectral width of beam emission lines allow for the measurement of the plasma magnetic field of 0.29 ± 0.007 T with the integration time of 200 μs.

  9. In vivo baseline measurements of hip joint range of motion in suspensory and nonsuspensory anthropoids.

    PubMed

    Hammond, Ashley S

    2014-03-01

    Hominoids and atelines are known to use suspensory behaviors and are assumed to possess greater hip joint mobility than nonsuspensory monkeys, particularly for range of abduction. This assumption has greatly influenced how extant and fossil primate hip joint morphology has been interpreted, despite the fact that there are no data available on hip mobility in hominoids or Ateles. This study uses in vivo measurements to test the hypothesis that suspensory anthropoids have significantly greater ranges of hip joint mobility than nonsuspensory anthropoids. Passive hip joint mobility was measured on a large sample of anesthetized captive anthropoids (nonhuman hominids = 43, hylobatids = 6, cercopithecids = 43, Ateles = 6, and Cebus = 6). Angular and linear data were collected using goniometers and tape measures. Range of motion (ROM) data were analyzed for significant differences by locomotor group using ANOVA and phylogenetic regression. The data demonstrate that suspensory anthropoids are capable of significantly greater hip abduction and external rotation. Degree of flexion and internal rotation were not larger in the suspensory primates, indicating that suspension is not associated with a global increase in hip mobility. Future work should consider the role of external rotation in abduction ability, how the physical position of the distal limb segments are influenced by differences in ROM proximally, as well as focus on bony and soft tissue differences that enable or restrict abduction and external rotation at the anthropoid hip joint.

  10. Brownian motion

    NASA Astrophysics Data System (ADS)

    Lavenda, B. H.

    1985-02-01

    Brownian motion, the doubly random motion of small particles suspended in a liquid due to molecular collisions, and its implications and applications in the history of modern science are discussed. Topics examined include probabilistic phenomena, the kinetic theory of gases, Einstein's atomic theory of Brownian motion, particle displacement, diffusion measurements, the determination of the mass of the atom and of Avogadro's number, the statistical mechanics of thermodynamics, nonequilibrium systems, Langevin's equation of motion, time-reversed evolution, mathematical analogies, and applications in economics and radio navigation. Diagrams and drawings are provided.

  11. The far distance to G7.47+0.06 from proper motion measurement of H2O masers

    NASA Astrophysics Data System (ADS)

    Yamauchi, Aya; Yamashita, Kazuyoshi; Honma, Mareki; Sunada, Kazuyoshi; Nakagawa, Akiharu; Ueno, Yuji

    2016-08-01

    We report on a distance measurement of 22 GHz H2O maser features associated with an ultra-compact H II region G7.47+0.06 using VERA (VLBI Exploration of Radio Astrometry). Since the source is located farther away than 10 kpc, it turned out to be difficult to derive the distance from annual parallax measurement. Meanwhile, we clearly detected the source's proper motion parallel to the Galactic plane. The proper motion is μ = -5.03 ± 0.07 mas yr-1 and is approaching the Galactic center. We applied a new method to determine the source distance based on absolute proper motions. Considering uncertainties of the Galactic rotation curve and the solar peculiar motion, the detected proper motion leads to a source distance of D = 20 ± 2 kpc, demonstrating that astrometric observation can provide an accurate distance measurement at a 10% level even for sources too distant to measure the annual parallax. Lastly, we scale the physical parameters of the H II region estimated in a previous paper to be 20 kpc, and show that the H2O maser features are associated with a massive star-forming region corresponding to the spectral type of O5.5.

  12. HST Astrometry in the 30 Doradus Region: Measuring Proper Motions of Individual Stars in the Large Magellanic Cloud

    NASA Astrophysics Data System (ADS)

    Platais, Imants; van der Marel, Roeland P.; Lennon, Daniel J.; Anderson, Jay; Bellini, Andrea; Sabbi, Elena; Sana, Hugues; Bedin, Luigi R.

    2015-09-01

    We present measurements of positions and relative proper motions in the 30 Doradus region of the LMC. We detail the construction of a single-epoch astrometric reference frame, based on specially designed observations obtained with the two main imaging instruments Advanced Camera for Surveys/Wide Field Channel and Wide Field Camera 3/UVIS on board the Hubble Space Telescope (HST). Internal comparisons indicate a sub milliarcsecond (mas) precision in the positions and the presence of semi-periodic systematics with a mean amplitude of ˜0.8 mas. We combined these observations with numerous archival images taken with Wide Field Planetary Camera 2 and spanning 17 years. The precision of the resulting proper motions for well-measured stars around the massive cluster Radcliffe 136 (R136) can be as good as ˜20 μas yr-1, although the true accuracy of proper motions is generally lower due to the residual systematic errors. The observed proper-motion dispersion for our highest-quality measurements is ˜0.1 mas yr-1. Our catalog of positions and proper motions contains 86,590 stars down to V ˜ 25 and over a total area of ˜70 square arcmin. We examined the proper motions of 105 relatively bright stars and identified a total of six candidate runaway stars. We are able to tentatively confirm the runaway status of star VFTS 285, consistent with the findings from line of sight velocities, and to show that this star has likely been ejected from R136. This study demonstrates that with HST it is now possible to reliably measure proper motions of individual stars in the nearest dwarf galaxies such as the LMC.

  13. Relation of motion sickness susceptibility to vestibular and behavioral measures of orientation

    NASA Technical Reports Server (NTRS)

    Peterka, Robert J.

    1994-01-01

    The objective of this proposal is to determine the relationship of motion sickness susceptibility to vestibulo-ocular reflexes (VOR), motion perception, and behavioral utilization of sensory orientation cues for the control of postural equilibrium. The work is focused on reflexes and motion perception associated with pitch and roll movements that stimulate the vertical semicircular canals and otolith organs of the inner ear. This work is relevant to the space motion sickness problem since 0 g related sensory conflicts between vertical canal and otolith motion cues are a likely cause of space motion sickness. Results of experimentation are summarized and modifications to a two-axis rotation device are described. Abstracts of a number of papers generated during the reporting period are appended.

  14. The First X-Ray Proper-Motion Measurements of the Forward Shock in the Northeastern Limb of Sn 1006

    NASA Technical Reports Server (NTRS)

    Katsuda, Satoru; Petre, Robert; Long, Knox S.; Reynolds, Stephen P.; Winkler, P. Frank; Mori, Koji; Tsunemi, Hiroshi

    2009-01-01

    We report on the first X-ray proper-motion measurements of the nonthermally-dominated forward shock in the northeastern limb of SN 1006, based on two Chandra observations taken in 2000 and 2008. We find that the proper motion of the forward shock is about 0.48"/yr and does not vary around the rim within the approx.10% measurement uncertainties. The proper motion measured is consistent with that determined by the previous radio observations. The mean expansion index of the forward shock is calculated to be approx..0.54 which matches the value expected based on an evolutionary model of a Type Ia supernova with either a power-law or an exponential ejecta density profile. Assuming pressure equilibrium around the periphery from the thermally-dominated northwestern rim to the nonthermally-dominated northeastern rim, we estimate the ambient density to the northeast of SN 1006 to be approx..0.085/cu cm.

  15. Development of a miniaturized position sensing system for measuring brain motion during impact - biomed 2013.

    PubMed

    Wing, I D; Merkle, A C; Armiger, R S; Carkhuff, B G; Roberts, J C

    2013-01-01

    Since 2000, the Department of Defense has documented more than 253,000 cases of Traumatic Brain Injury (TBI). A significant portion of these injuries were attributed to explosive events, yet ninety-eight percent were non-penetrating. Understanding the response of the brain to blast events is critical, yet the mechanisms of brain injury from explosive trauma are poorly understood. This knowledge gap has led to an increased research focus on devices capable of investigating human brain response to non-penetrating, blast-induced loading. Furthermore, traumatic brain injury is a major issue for the civilian population as well with over 1.7 million cases of TBI per year in the US, primarily from falls and motor vehicle accidents. Current head surrogates and instrumentation are incapable of directly measuring critical parameters associated with TBI, such as brain motion, during dynamic loading. To this end, a novel sensor system for measuring brain motion inside of a human head surrogate was conceptualized and developed. The positioning system is comprised of a set of three fixed “generator” coils and a plurality of mobile, miniaturized “receiver” coil triads. Each generator coil transmits a sinusoidal electromagnetic signal at a unique frequency, and groups of three orthogonally arranged “receiver” coils detect these signals. Because of the oscillatory nature of these signals, the magnetic flux through the coil is always changing, allowing the application of Faraday’s Law of Induction and the point dipole model of an electric field to model the strength and direction of the field vector at any given point. Thus, the strength of the signal measured by a particular receiver coil depends on its position and orientation relative to the fixed position of the generators. These predictable changes are used to determine the six degrees of freedom (6-DOF) motion of the receiver. To calibrate and validate the system, a receiver coil was moved about in a controlled manner

  16. Measurement of the motional sidebands of a nanogram-scale oscillator in the quantum regime

    NASA Astrophysics Data System (ADS)

    Underwood, M.; Mason, D.; Lee, D.; Xu, H.; Jiang, L.; Shkarin, A. B.; Børkje, K.; Girvin, S. M.; Harris, J. G. E.

    2015-12-01

    We describe measurements of the motional sidebands produced by a mechanical oscillator (with effective mass 43 ng and resonant frequency 705 kHz) that is placed in an optical cavity and cooled close to its quantum ground state. The red and blue sidebands (corresponding to Stokes and anti-Stokes scattering) from a single laser beam are recorded simultaneously via a heterodyne measurement. The oscillator's mean phonon number n ¯ is inferred from the ratio of the sidebands, and reaches a minimum value of 0.84 ±0.22 (corresponding to a mode temperature T =28 ±7 μ K ). We also infer n ¯ from the calibrated area of each of the two sidebands, and from the oscillator's total damping. The values of n ¯ inferred from these four methods are in close agreement. The behavior of the sidebands as a function of the oscillator's temperature agrees well with theory that includes the quantum fluctuations of both the cavity field and the mechanical oscillator.

  17. 3D digital holographic interferometry as a tool to measure the tympanic membrane motion

    NASA Astrophysics Data System (ADS)

    del Socorro Hernández-Montes, M.; Muñoz Solis, S.; Mendoza Santoyo, F.

    2012-10-01

    Most of the current optical non-invasive methodologies used to characterize the tympanic membrane (TM) motion generate data in the z direction only, i.e., employ an out-of-plane sensitive configuration. In this paper, 3-D digital holographic interferometry (3-D DHI), is used to measure micrometer displacements from the TM surface. The proposed optical configuration provides information from three sensitivity vectors that separate the contributions from x, y and z displacement components. In order to achieve high accuracy of the sensitivity vector and to obtain the complete determination of the 3-D TM displacements, its surface contour is obtained by moving only two object illumination sources chosen from any pair within the DHI optical setup. Results are presented from measurements corresponding to individual displacements maps for the three orthogonal displacements components x, y and z combined with the TM shape from an ex-vivo cat. These results will no doubt contribute to enhance the understanding and determinate the mechanical properties of this complex tissue.

  18. Watt-linkage based sensors for low frequency motion measurement and control of spacecrafts and satellites

    NASA Astrophysics Data System (ADS)

    Acernese, F.; Giordano, G.; Romano, R.; Barone, F.

    2014-03-01

    This paper describes a new mechanical application of the Watt-linkage for the development and implementation of mono-axial sensors aimed to low frequency motion measurement and control of spacecrafts and satellites. The basic component of these sensors is the one dimensional UNISA Folded Pendulum mechanical sensor, developed for ground-based applications, whose unique features are due to a very effective optimization of the effects of gravitational force on the folded pendulum mechanical components, that allowed the design and implementation of FP sensors compact (< 10 cm), light (< 200 g), scalable, tunable resonance frequency < 100mHz), with large band (10-7 Hz - 10Hz), high quality factor (Q > 15000 in vacuum at 1Hz), with good immunity to environmental noises and sensitivity, guaranteed by an integrated laser optical readout, and fully adaptable to the specific requirements of the application. In this paper we show how to extend the application of ground-based FP also to space, in absence of gravity, still keeping all the above interesting features and characteristics that make this class of sensors very effective in terms of large band, especially in the low frequency, sensitivity and long term reliability. Preliminary measurements on a prototype confirm the feasibility, showing also that very good performances can be relatively easily obtained.

  19. Wearable motion sensors to continuously measure real-world physical activities

    PubMed Central

    Dobkin, Bruce H.

    2014-01-01

    Purpose of review Rehabilitation for sensorimotor impairments aims to improve daily activities, walking, exercise, and motor skills. Monitoring of practice and measuring outcomes, however, is usually restricted to laboratory-based procedures and self-reports. Mobile health devices may reverse these confounders of daily care and research trials. Recent findings Wearable, wireless motion sensor data, analyzed by activity pattern-recognition algorithms, can describe the type, quantity, and quality of mobility-related activities in the community. Data transmission from sensors to the cell phone and Internet enable continuous monitoring. Remote access to laboratory-quality data about walking speed, duration and distance, gait asymmetry and smoothness of movements, as well as cycling, exercise, and skills practice, opens new opportunities to engage patients in progressive, personalized therapies with feedback about performance. Clinical trial designs will be able to include remote verification of the integrity of complex physical interventions and compliance with practice, as well as capture repeated, ecologically sound, ratio-scale outcome measures. Summary Given the progressively falling cost of miniaturized wearable gyroscopes, accelerometers, and other physiologic sensors, as well as inexpensive data transmission, sensing systems may become as ubiquitous as cell phones for health care. Neurorehabilitation can develop these mobile health platforms for daily care and clinical trials to improve exercise and fitness, skills learning, and physical functioning. PMID:24136126

  20. Reliability of Goniometric and Trigonometric Techniques for Measuring Hip-Extension Range of Motion Using the Modified Thomas Test

    PubMed Central

    Wakefield, C. Brent; Halls, Amanda; Difilippo, Nicole; Cottrell, G. Trevor

    2015-01-01

    Context: Goniometric assessment of hip-extension range of motion is a standard practice in clinical rehabilitation settings. A weakness of goniometric measures is that small errors in landmarking may result in substantial measurement error. A less commonly used protocol for measuring hip range of motion involves applying trigonometric principles to the length and vertical displacement of the upper part of the lower extremity to determine hip angle; however, the reliability of this measure has never been assessed using the modified Thomas test. Objective: To compare the intrarater and interrater reliability of goniometric (GON) and trigonometric (TRIG) techniques for assessing hip-extension range of motion during the modified Thomas test. Design: Controlled laboratory study. Setting: Institutional athletic therapy facility. Patients or Other Participants: A total of 22 individuals (12 men, 10 women; age range, 18–36 years) with no pathologic knee or back conditions. Main Outcome Measure(s): Hip-extension range of motion of each participant during a modified Thomas test was assessed by 2 examiners with both GON and TRIG techniques in a randomly selected order on 2 separate days. Results: The intraclass correlation coefficient (ICC) revealed that the reliability of the GON technique was low for both the intrarater (ICC = 0.51, 0.54) and interrater (ICC = 0.30, 0.65) comparisons, but the reliability of the TRIG technique was high for both intrarater (ICC = 0.90, 0.95) and interrater (ICC = 0.91, 0.94) comparisons. Single-factorial repeated-measures analyses of variance revealed no mean differences in scoring within or between examiners for either measurement protocol, whereas a difference was observed when comparing the TRIG and GON tests due to the differences in procedures used to identify landmarks. Conclusions: Using the TRIG technique to measure hip-extension range of motion during the modified Thomas test results in superior intrarater and interrater

  1. The measured performance of an air thermosyphon system

    NASA Astrophysics Data System (ADS)

    Marshall, L. S.; Burns, P. J.; Winn, C. B.

    Results of performance tests of a solar thermosyphon test cell are reported. The test cell comprised a structure on a concrete slab with fiberglass insulated walls. The north wall consisted of a styrofoam-insulated gravel-filled box, while the south wall featured double glazing over metal solar collectors. The ceiling was ducted to provide air flow from the south collector to the rock storage, and an air channel was built into the floor. A numerical model was developed of the expected performance of the cell, using an Euler technique to solve the transient energy and momentum equations. The temperature was monitored at various points of the structure and flow visualization studies were made with titanium tetrachloride. Heat was found to be stored in the upper portion of the rock box, which because of its size also inhibited circulation. Thermal comfort was determined to be available due to warm surfaces, rather than warm air.

  2. Measuring air layer volumes retained by submerged floating-ferns Salvinia and biomimetic superhydrophobic surfaces

    PubMed Central

    Reker, Meike; Barthlott, Wilhelm

    2014-01-01

    Summary Some plants and animals feature superhydrophobic surfaces capable of retaining a layer of air when submerged under water. Long-term air retaining surfaces (Salvinia-effect) are of high interest for biomimetic applications like drag reduction in ship coatings of up to 30%. Here we present a novel method for measuring air volumes and air loss under water. We recorded the buoyancy force of the air layer on leaf surfaces of four different Salvinia species and on one biomimetic surface using a highly sensitive custom made strain gauge force transducer setup. The volume of air held by a surface was quantified by comparing the buoyancy force of the specimen with and then without an air layer. Air volumes retained by the Salvinia-surfaces ranged between 0.15 and 1 L/m2 depending on differences in surface architecture. We verified the precision of the method by comparing the measured air volumes with theoretical volume calculations and could find a good agreement between both values. In this context we present techniques to calculate air volumes on surfaces with complex microstructures. The introduced method also allows to measure decrease or increase of air layers with high accuracy in real-time to understand dynamic processes. PMID:24991518

  3. Measuring air layer volumes retained by submerged floating-ferns Salvinia and biomimetic superhydrophobic surfaces.

    PubMed

    Mayser, Matthias J; Bohn, Holger F; Reker, Meike; Barthlott, Wilhelm

    2014-01-01

    Some plants and animals feature superhydrophobic surfaces capable of retaining a layer of air when submerged under water. Long-term air retaining surfaces (Salvinia-effect) are of high interest for biomimetic applications like drag reduction in ship coatings of up to 30%. Here we present a novel method for measuring air volumes and air loss under water. We recorded the buoyancy force of the air layer on leaf surfaces of four different Salvinia species and on one biomimetic surface using a highly sensitive custom made strain gauge force transducer setup. The volume of air held by a surface was quantified by comparing the buoyancy force of the specimen with and then without an air layer. Air volumes retained by the Salvinia-surfaces ranged between 0.15 and 1 L/m(2) depending on differences in surface architecture. We verified the precision of the method by comparing the measured air volumes with theoretical volume calculations and could find a good agreement between both values. In this context we present techniques to calculate air volumes on surfaces with complex microstructures. The introduced method also allows to measure decrease or increase of air layers with high accuracy in real-time to understand dynamic processes.

  4. Nanomechanical motion measured with an imprecision below the standard quantum limit using a nearly shot-noise limited microwave interferometer

    NASA Astrophysics Data System (ADS)

    Harlow, Jennifer; Teufel, John; Donner, Tobias; Castellanos-Beltran, Manuel; Lehnert, Konrad

    2010-03-01

    Observing quantum behavior of mechanical motion is challenging because it is difficult both to prepare pure quantum states of motion and to detect those states with sufficient precision. We present displacement measurements of a nanomechanical oscillator with an imprecision below that at the standard quantum limit [1]. We infer the motion from the phase modulation imprinted on a microwave signal by that motion. The modulation is enhanced by embedding the oscillator in a high-Q microwave cavity. We achieve the low imprecision by reading out the modulation with a Josephson Parametric Amplifier, realizing a microwave interferometer that operates near the shot-noise limit. The apparent motion of the mechanical oscillator due the interferometer's noise is now substantially less than its zero-point motion, making future detection of quantum states feasible. In addition, the phase sensitivity of the demonstrated interferometer is 30 times higher than previous microwave interferometers, providing a critical piece of technology for many experiments investigating quantum information encoded in microwave fields. [1] J. D. Teufel, T. Donner, M. A. Castellanos-Beltran, J. W. Harlow, K. W. Lehnert, Nature Nanotechnology, doi:10.1038/nnano.2009.343, (2009).

  5. 30 CFR 75.320 - Air quality detectors and measurement devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Air quality detectors and measurement devices... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.320 Air quality detectors and measurement devices. (a) Tests for methane shall be made by a qualified person...

  6. A Simple Experiment To Measure the Content of Oxygen in the Air Using Heated Steel Wool

    ERIC Educational Resources Information Center

    Vera, Francisco; Rivera, Rodrigo; Nunez, Cesar

    2011-01-01

    The typical experiment to measure the oxygen content in the atmosphere uses the rusting of steel wool inside a closed volume of air. Two key aspects of this experiment that make possible a successful measurement of the content of oxygen in the air are the use of a closed atmosphere and the use of a chemical reaction that involves the oxidation of…

  7. Measurements of soot, OH, and PAH concentrations in turbulent ethylene/air jet flames

    SciTech Connect

    Lee, Seong-Young; Turns, Stephen R.; Santoro, Robert J.

    2009-12-15

    This paper presents results from an investigation of soot formation in turbulent, non-premixed, C{sub 2}H{sub 4}/air jet flames. Tests were conducted using a H{sub 2}-piloted burner with fuel issuing from a 2.18 mm i.d. tube into quiescent ambient air. A range of test conditions was studied using the initial jet velocity (16.2-94.1 m/s) as a parameter. Fuel-jet Reynolds numbers ranged from 4000 to 23,200. Planar laser-induced incandescence (LII) was employed to determine soot volume fractions, and laser-induced fluorescence (LIF) was used to measure relative hydroxyl radical (OH) concentrations and polycyclic aromatic hydrocarbons (PAHs) concentrations. Extensive information on the structure of the soot and OH fields was obtained from two-dimensional imaging experiments. Quantitative measurements were obtained by employing the LII and LIF techniques independently. Imaging results for soot, OH, and PAH show the existence of three soot formation/oxidation regions: a rapid soot growth region, in which OH and soot particles lie in distinctly different radial locations; a mixing-dominated region controlled by large-scale motion; and a soot-oxidation region in which the OH and soot fields overlap spatially, resulting in the rapid oxidation of soot particles. Detailed quantitative analyzes of soot volume fractions and OH and soot zone thicknesses were performed along with the temperature measurement using the N{sub 2}-CARS system. Measurements of OH and soot zone thicknesses show that the soot zone thickness increases linearly with axial distance in the soot formation region, whereas the OH zone thickness is nearly constant in this region. The OH zone thickness then rapidly increases with downstream distance and approximately doubles in the soot-oxidation region. Probability density functions also were obtained for soot volume fractions and OH concentrations. These probability density functions clearly define the spatial relationships among the OH, PAH concentrations, the

  8. Nitric oxide density measurements in air and air/fuel nanosecond pulse discharges by laser induced fluorescence

    NASA Astrophysics Data System (ADS)

    Uddi, M.; Jiang, N.; Adamovich, I. V.; Lempert, W. R.

    2009-04-01

    Laser induced fluorescence is used to measure absolute nitric oxide concentrations in air, methane-air and ethylene-air non-equilibrium plasmas, as a function of time after initiation of a single pulse, 20 kV peak voltage, 25 ns pulse duration discharge. A mixture of NO and nitrogen with known composition (4.18 ppm NO) is used for calibration. Peak NO density in air at 60 Torr, after a single pulse, is ~8 × 1012 cm-3 (~4.14 ppm) occurring at ~250 µs after the pulse, with decay time of ~16.5 ms. Peak NO atom mole fraction in a methane-air mixture with equivalence ratio of phiv = 0.5 is found to be approximately equal to that in air, with approximately the same rise and decay rate. In an ethylene-air mixture (also with equivalence ratio of phiv = 0.5), the rise and decay times are comparable to air and methane-air, but the peak NO concentration is reduced by a factor of approximately 2.5. Spontaneous emission measurements show that excited electronic states N2(C 3Π) and NO(A 2Σ) in air at P = 60 Torr decay within ~20 ns and ~1 µs, respectively. Kinetic modelling calculations incorporating air plasma kinetics complemented with the GRI Mech 3.0 hydrocarbon oxidation mechanism are compared with the experimental data using three different NO production mechanisms. It is found that NO concentration rise after the discharge pulse is much faster than predicted by Zel'dovich mechanism reactions, by two orders of magnitude, but much slower compared with reactions of electronically excited nitrogen atoms and molecules, also by two orders of magnitude. It is concluded that processes involving long lifetime (~100 µs) metastable states, such as N2(X 1Σ,v) and O2(b 1Σ), formed by quenching of the metastable N2(A 3Σ) state by ground electronic state O2, may play a dominant role in NO formation. NO decay, in all cases, is found to be dominated by the reverse Zel'dovich reaction, NO + O → N + O2, as well as by conversion into NO2 in a reaction of NO with ozone.

  9. Water and Air Measures That Make 'PureSense'

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Each day, we read about mounting global concerns regarding the ability to sustain supplies of clean water and to reduce air contamination. With water and air serving as life s most vital elements, it is important to know when these environmental necessities may be contaminated, in order to eliminate exposure immediately. The ability to respond requires an understanding of the conditions impacting safety and quality, from source to tap for water, and from outdoor to indoor environments for air. Unfortunately, the "time-to-know" is not immediate with many current technologies, which is a major problem, given the greater likelihood of risky situations in today s world. Accelerating alert and response times requires new tools, methods, and technologies. New solutions are needed to engage in more rapid detection, analysis, and response. This is the focus of a company called PureSense Environmental, Inc., which evolved out of a unique relationship with NASA. The need for real-time management and operations over the quality of water and air, and the urgency to provide new solutions, were reinforced by the events of September 11, 2001. This, and subsequent events, exposed many of the vulnerabilities facing the multiple agencies tasked with working in tandem to protect communities from harmful disaster. Much has been done since September 11 to accelerate responses to environmental contamination. Partnerships were forged across the public and private sectors to explore, test, and use new tools. Methods and technologies were adopted to move more astutely from proof-of-concept to working solutions.

  10. Mobile Air Monitoring Data Processing Strategies and Effects on Spatial Air Pollution Trends

    EPA Science Inventory

    The collection of real-time air quality measurements while in motion (i.e., mobile monitoring) is currently conducted worldwide to evaluate in situ emissions, local air quality trends, and air pollutant exposure. This measurement strategy pushes the limits of traditional data an...

  11. Rectilinear-motion space inversion-based detection approach for infrared dim air targets with variable velocities

    NASA Astrophysics Data System (ADS)

    Ma, Tianlei; Shi, Zelin; Yin, Jian; Liu, Yunpeng; Xu, Baoshu; Zhang, Chengshuo

    2016-03-01

    Dim targets are extremely difficult to detect using methods based on single-frame detection. Radiation accumulation is one of the effective methods to improve signal-to-noise ratio (SNR). A detection approach based on radiation accumulation is proposed. First, a location space and a motion space are established. Radiation accumulation operation, controlled by vectors from the motion space, is applied to the original image space. Then, a new image space is acquired where some images have an improved SNR. Second, quasitargets in the new image space are obtained by constant false-alarm ratio judging, and location vectors and motion vectors of quasitargets are also acquired simultaneously. Third, the location vectors and motion vectors are mapped into the two spaces, respectively. Volume density function is defined in the motion space. Location extremum of the location space and volume density extremum of motion space will confirm the true target. Finally, actual location of the true target in the original image space is obtained by space inversion. The approach is also applicable to detect multiple dim targets. Experimental results show the effectiveness of the proposed approach and demonstrate the approach is superior to compared approaches on detection probability and false alarm probability.

  12. Automatic target recognition using both measurements from identity sensors and motion information from tracking sensors

    NASA Astrophysics Data System (ADS)

    Copsey, Keith D.

    2005-05-01

    The majority of automatic target recognition (ATR) studies are formulated as a traditional classification problem. Specifically, using a training set of target exemplars, a classifier is developed for application to isolated measurements of targets. Performance is assessed using a test set of target exemplars. Unfortunately, this is a simplification of the ATR problem. Often, the operating conditions differ from those prevailing at the time of training data collection, which can have severe effects on the obtained performance. It is therefore becoming increasingly recognised that development of robust ATR systems requires more than just consideration of the traditional classification problem. In particular, one should make use of any extra information or data that is available. The example in this paper focuses on a hybrid ATR system being designed to utilise both measurements from identity sensors (such as radar profiles) and motion information from tracking sensors to classify targets. The first-stage of the system uses mixture-model classifiers to classify targets into generic classes based upon data from (long range) tracking sensors. Where the generic classes are related to platform types (e.g. fast-jets, heavy bombers and commercial aircraft), the initial classifications can be used to assist the military commander's early decision making. The second-stage of the system uses measurements from (closer-range) identity sensors to classify the targets into individual target types, while taking into account the (uncertain) outputs from the first-stage. A Bayesian classifier is proposed for the second-stage, so that the first-stage outputs can be incorporated into the second-stage prior class probabilities.

  13. Processing of translational and rotational motions of surface waves: performance analysis and applications to single sensor and to array measurements

    NASA Astrophysics Data System (ADS)

    Maranò, Stefano; Fäh, Donat

    2014-01-01

    The analysis of rotational seismic motions has received considerable attention in the last years. Recent advances in sensor technologies allow us to measure directly the rotational components of the seismic wavefield. Today this is achieved with improved accuracy and at an affordable cost. The analysis and the study of rotational motions are, to a certain extent, less developed than other aspects of seismology due to the historical lack of instrumental observations. This is due to both the technical challenges involved in measuring rotational motions and to the widespread belief that rotational motions are insignificant. This paper addresses the joint processing of translational and rotational motions from both the theoretical and the practical perspectives. Our attention focuses on the analysis of motions of both Rayleigh waves and Love waves from recordings of single sensors and from an array of sensors. From the theoretical standpoint, analysis of Fisher information (FI) allows us to understand how the different measurement types contribute to the estimation of quantities of geophysical interest. In addition, we show how rotational measurements resolve ambiguity on parameter estimation in the single sensor setting. We quantify the achievable estimation accuracy by means of Cramér-Rao bound (CRB). From the practical standpoint, a method for the joint processing of rotational and translational recordings to perform maximum likelihood (ML) estimation is presented. The proposed technique estimates parameters of Love waves and Rayleigh waves from single sensor or array recordings. We support and illustrate our findings with a comprehensive collection of numerical examples. Applications to real recordings are also shown.

  14. Accurate respiration measurement using DC-coupled continuous-wave radar sensor for motion-adaptive cancer radiotherapy.

    PubMed

    Gu, Changzhan; Li, Ruijiang; Zhang, Hualiang; Fung, Albert Y C; Torres, Carlos; Jiang, Steve B; Li, Changzhi

    2012-11-01

    Accurate respiration measurement is crucial in motion-adaptive cancer radiotherapy. Conventional methods for respiration measurement are undesirable because they are either invasive to the patient or do not have sufficient accuracy. In addition, measurement of external respiration signal based on conventional approaches requires close patient contact to the physical device which often causes patient discomfort and undesirable motion during radiation dose delivery. In this paper, a dc-coupled continuous-wave radar sensor was presented to provide a noncontact and noninvasive approach for respiration measurement. The radar sensor was designed with dc-coupled adaptive tuning architectures that include RF coarse-tuning and baseband fine-tuning, which allows the radar sensor to precisely measure movement with stationary moment and always work with the maximum dynamic range. The accuracy of respiration measurement with the proposed radar sensor was experimentally evaluated using a physical phantom, human subject, and moving plate in a radiotherapy environment. It was shown that respiration measurement with radar sensor while the radiation beam is on is feasible and the measurement has a submillimeter accuracy when compared with a commercial respiration monitoring system which requires patient contact. The proposed radar sensor provides accurate, noninvasive, and noncontact respiration measurement and therefore has a great potential in motion-adaptive radiotherapy.

  15. Fast-starting after a breath: air-breathing motions are kinematically similar to escape responses in the catfish Hoplosternum littorale

    PubMed Central

    Domenici, Paolo; Norin, Tommy; Bushnell, Peter G.; Johansen, Jacob L.; Skov, Peter Vilhelm; Svendsen, Morten B. S.; Steffensen, John F.; Abe, Augusto S.

    2015-01-01

    ABSTRACT Fast-starts are brief accelerations commonly observed in fish within the context of predator–prey interactions. In typical C-start escape responses, fish react to a threatening stimulus by bending their body into a C-shape during the first muscle contraction (i.e. stage 1) which provides a sudden acceleration away from the stimulus. Recently, similar C-starts have been recorded in fish aiming at a prey. Little is known about C-starts outside the context of predator–prey interactions, though recent work has shown that escape response can also be induced by high temperature. Here, we test the hypothesis that air-breathing fish may use C-starts in the context of gulping air at the surface. Hoplosternum littorale is an air-breathing freshwater catfish found in South America. Field video observations reveal that their air-breathing behaviour consists of air-gulping at the surface, followed by a fast turn which re-directs the fish towards the bottom. Using high-speed video in the laboratory, we compared the kinematics of the turn immediately following air-gulping performed by H. littorale in normoxia with those of mechanically-triggered C-start escape responses and with routine (i.e. spontaneous) turns. Our results show that air-breathing events overlap considerably with escape responses with a large stage 1 angle in terms of turning rates, distance covered and the relationship between these rates. Therefore, these two behaviours can be considered kinematically comparable, suggesting that air-breathing in this species is followed by escape-like C-start motions, presumably to minimise time at the surface and exposure to avian predators. These findings show that C-starts can occur in a variety of contexts in which fish may need to get away from areas of potential danger. PMID:25527644

  16. High-precision diode-laser-based temperature measurement for air refractive index compensation

    SciTech Connect

    Hieta, Tuomas; Merimaa, Mikko; Vainio, Markku; Seppae, Jeremias; Lassila, Antti

    2011-11-01

    We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements, it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlen equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilizes direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well-matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially nonhomogeneous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using a 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.

  17. Do inertial sensors represent a viable method to reliably measure cervical spine range of motion?

    PubMed

    Theobald, Peter S; Jones, Michael D; Williams, Jonathan M

    2012-02-01

    A rise in neck pain cases has initiated an exponential interest in the assessment and treatment of cervical spine range of motion (CROM). Experimental limitations, however, have been reported as therapists strive to collect continuous, dynamic data to aid prognosis. This technical report seeks to explore the viability of using inertial sensors to reliably assess CROM. In recognition of the need for secure skin-sensor attachment, four combinations of sensor pairings were established and investigated based upon four clinically identifiable surface landmarks. Twelve participants were recruited and asked to perform three specific movement cycles in each plane (i.e. flexion-extension; rotation; lateral bending). The reliability of the peak CROM, and the movement pattern, recorded in each of the three movement cycles was statistically analysed using the intra-class correlation coefficient (ICC) and coefficient of multiple correlations (CMC). It was determined that the most reliable positions of the orientation sensors, with one adhered to the forehead and the other representing T4, enables data to be recorded with a reliability that is comparable to other CROM measuring techniques. Subsequently, it is concluded that inertial sensors represent a viable method to assess CROM. PMID:21784696

  18. Reliability and Validity of Electro-Goniometric Range of Motion Measurements in Patients with Hand and Wrist Limitations

    PubMed Central

    Bashardoust Tajali, Siamak; MacDermid, Joy C.; Grewal, Ruby; Young, Chris

    2016-01-01

    Study Design: Cross-sectional reliability and validity study. Purpose: 1. To determine intrarater, interrater and inter instrument reliabilities and validity of two digital electro goniometry to measure active wrist/finger range of motions (ROMs) in patients with limited motion. 2. To determine intrarater and interrater reliabilities of digital goniometry to measure torques of PIP passive flexion of the index finger in patients with limited motion. Methods: The study was designed in a randomized block plan on 44 patients (24 women, 20 men) with limited wrist or hand motions. Two experienced raters measured active wrist ROMs, and active and passive index PIP flexion using two digital goniometers. All measures were repeated by one rater 2-5 days after the initial measurements. The reliability measures were analyzed using Intraclass Correlation Coefficients (ICCs) and the construct validity was determined by correlation coefficients analysis between sub measures of scores; patient rated pain and function (PRWE) and quick Disabilities of the Arm, Shoulder and Hand (quick DASH) scores. Results: The intrarater, interrater and inter instrument reliabilities were high in most ROM measures (range 0.64-0.97) for both types of electro-goniometers. The 95% limit of agreements and Bland and Altman plots did not show progressive changes. There was a significant difference in force application between the raters when performing passive ROM measures for PIP index, but the same rater produced consistent force. Most of the NK and J-Tech ROM measures were moderately correlated with the patient rated pain and function scores (range 0.32-0.63). PMID:27398107

  19. Polarization Methods of Measuring the Roll Angle of an Object in Motion in Radio Beacon Navigation Systems

    NASA Astrophysics Data System (ADS)

    Gulko, V. L.; Mescheryakov, A. A.

    2016-06-01

    Polarization methods of measuring the roll angle of an object in motion with the help of radio beacon systems are considered. The polarization properties of the beacon signals received on board the object and amplitude-phase processing of their orthogonal polarized components are used to accomplish this goal.

  20. Measure Guideline. Air Conditioner Diagnostics, Maintenance, and Replacement

    SciTech Connect

    Springer, David; Dakin, Bill

    2013-03-01

    This guideline responds to the need for an efficient means of identifying, diagnosing, and repairing faults in air conditioning systems in existing homes that are undergoing energy upgrades. Inadequate airflow due to constricted ducts or undersized filters, improper refrigerant charge, and other system defects can be corrected at a fraction of the cost of equipment replacement and can yield significant savings. The guideline presents a two-step approach to diagnostics and repair.

  1. Measure Guideline: Air Conditioner Diagnostics, Maintenance, and Replacement

    SciTech Connect

    Springer, D.; Dakin, B.

    2013-03-01

    This guideline responds to the need for an efficient means of identifying, diagnosing, and repairing faults in air conditioning systems in existing homes that are undergoing energy upgrades. Inadequate airflow due to constricted ducts or undersized filters, improper refrigerant charge, and other system defects can be corrected at a fraction of the cost of equipment replacement and can yield significant savings. The guideline presents a two-step approach to diagnostics and repair.

  2. Air Flow and Pressure Drop Measurements Across Porous Oxides

    NASA Technical Reports Server (NTRS)

    Fox, Dennis S.; Cuy, Michael D.; Werner, Roger A.

    2008-01-01

    This report summarizes the results of air flow tests across eight porous, open cell ceramic oxide samples. During ceramic specimen processing, the porosity was formed using the sacrificial template technique, with two different sizes of polystyrene beads used for the template. The samples were initially supplied with thicknesses ranging from 0.14 to 0.20 in. (0.35 to 0.50 cm) and nonuniform backside morphology (some areas dense, some porous). Samples were therefore ground to a thickness of 0.12 to 0.14 in. (0.30 to 0.35 cm) using dry 120 grit SiC paper. Pressure drop versus air flow is reported. Comparisons of samples with thickness variations are made, as are pressure drop estimates. As the density of the ceramic material increases the maximum corrected flow decreases rapidly. Future sample sets should be supplied with samples of similar thickness and having uniform surface morphology. This would allow a more consistent determination of air flow versus processing parameters and the resulting porosity size and distribution.

  3. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

    SciTech Connect

    Walker, Iain; Stratton, Chris

    2015-08-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  4. Spinal motion and intradiscal pressure measurements before and after lumbar spine instrumentation with titanium or PEEK rods.

    PubMed

    Abode-Iyamah, Kingsley; Kim, Sam Byeong; Grosland, Nicole; Kumar, Rajinder; Belirgen, Muhittin; Lim, Tae Hong; Torner, James; Hitchon, Patrick W

    2014-04-01

    Spinal instrumentation and fusion have been incriminated as contributing to adjacent segment degeneration (ASD). It has been suggested that ASD results from increased range of motion and intradiscal pressure (IDP) adjacent to instrumentation. Posterior dynamic stabilization with polyetheretherketone (PEEK) rods has been proposed as potentially advantageous compared to rigid instrumentation with titanium (Ti) rods in reducing the incidence of ASD. We evaluated segmental motions in the cadaveric spine instrumented with PEEK or Ti rods from L3 to S1, as well as the adjacent segment motions and IDP at L1-2 and L2-3. Human cadaveric spines were potted at T12-L1 and S1-2. Spinal instrumentation from L3-S1 was accomplished using pedicle screws with either PEEK or Ti rods. Specimens were subjected to displacement controlled testing: 15° flexion, 15° extension, 10° lateral bending, and 5° right axial rotation using the MTS machine (MTS, Minneapolis, MN, USA). Intradiscal pressure was measured by placing pressure transducers into the intervertebral disc at L1-2 and L2-3. Spinal motion of L2 relative to L3, and L3 relative to S1 was tracked using a three dimensional motion analysis system. Instrumentation with PEEK and Ti rods was associated with a decrease in L3-S1 motion compared to the intact state that was significant in flexion (p=0.002), and extension (p=0.0075). Instrumentation with PEEK and Ti rods was associated with an increase in IDP at L1-2 that was significant in flexion (p=0.0028). Instrumentation with either PEEK or Ti rods resulted in decreased motion at the instrumented levels while increasing IDP at the adjacent level.

  5. Twenty years of measurement of polycyclic aromatic hydrocarbons (PAHs) in UK ambient air by nationwide air quality networks.

    PubMed

    Brown, Andrew S; Brown, Richard J C; Coleman, Peter J; Conolly, Christopher; Sweetman, Andrew J; Jones, Kevin C; Butterfield, David M; Sarantaridis, Dimitris; Donovan, Brian J; Roberts, Ian

    2013-06-01

    The impact of human activities on the health of the population and of the wider environment has prompted action to monitor the presence of toxic compounds in the atmosphere. Toxic organic micropollutants (TOMPs) are some of the most insidious and persistent of these pollutants. Since 1991 the United Kingdom has operated nationwide air quality networks to assess the presence of TOMPs, including polycyclic aromatic hydrocarbons (PAHs), in ambient air. The data produced in 2010 marked 20 years of nationwide PAH monitoring. This paper marks this milestone by providing a novel and critical review of the data produced since nationwide monitoring began up to the end of 2011 (the latest year for which published data is available), discussing how the networks performing this monitoring has evolved, and elucidating trends in the concentrations of the PAHs measured. The current challenges in the area and a forward look to the future of air quality monitoring for PAHs are also discussed briefly. PMID:23636622

  6. Measure Guideline: Air Sealing Mechanical Closets in Slab-On-Grade Homes

    SciTech Connect

    Dickson, B.

    2012-02-01

    This measure guideline describes covers two fundamental retrofit strategies for air sealing around air handling systems that are located within the living space in an enclosed closet: one in which all of the equipment is removed and being replaced, and a closet where the equipment is to remain and existing conditions are sealed. It includes the design and installation details necessary to effectively seal the air handler closet and central return system to maximize the efficiency and safety of the space conditioning system.

  7. Measure Guideline. Air Sealing Mechanical Closets in Slab-on-Grade Homes

    SciTech Connect

    Dickson, Bruce

    2012-02-01

    This measure guideline describes two fundamental retrofit strategies for air sealing around air handling systems that are located within the living space in an enclosed closet: one in which all of the equipment is removed and being replaced, and a closet where the equipment is to remain and existing conditions are sealed. It includes the design and installation details necessary to effectively seal the air handler closet and central return system to maximize the efficiency and safety of the space conditioning system.

  8. Image Processing Method of the Motion-Capturing PSP/TSP for the Measurement of a Free-Flight Object

    NASA Astrophysics Data System (ADS)

    Ishii, Masato; Goya, Hideki; Miyazaki, Takeshi; Sakaue, Hirotaka

    2015-11-01

    The motion-capturing PSP/TSP system consists of a two-color PSP/TSP and a high-speed color camera. Red and green luminescent images are acquired simultaneously as signal and reference outputs by this system. Simply by rationing the red and the green images, we can obtain a pressure/temperature distribution on the surface of a target object. This system is applied to measure the surface pressure/temperature of a free-flight object. However, an acquired image includes motion blur, focus blur and random noise around the object. We discuss image processing methods and evaluations to optimize those uncertainties. Three types of the edge detect methods are used, which are the sobel, the laplassian and the canny. We will also show the evaluation results to discuss an optimized image processing for the motion-capturing PSP/TSP system.

  9. Measurement of creepage distance and air clearance: differences between different professionals

    NASA Astrophysics Data System (ADS)

    de Oliveira Silva, Aline; Takachi Moriya, Henrique; Cortez, Tiago; Moraes, José Carlos T. B.

    2016-07-01

    The standard IEC/ISO 60601-1:2005 specifies general requirements for measuring creepage distance and air clearance for medical electrical equipment. Four experienced professionals were asked to measure creepage distances and air clearance in three different segments of an acrylic body of proof. The results were compared and the found differences were discussed in order to discover the misinterpretations of the standard requirements. After a final consensus between the professionals, the distances were measured again to obtain the final results.

  10. RESIDUAL GAS MOTIONS IN THE INTRACLUSTER MEDIUM AND BIAS IN HYDROSTATIC MEASUREMENTS OF MASS PROFILES OF CLUSTERS

    SciTech Connect

    Lau, Erwin T.; Kravtsov, Andrey V.; Nagai, Daisuke

    2009-11-10

    We present analysis of bulk and random gas motions in the intracluster medium using high-resolution Eulerian cosmological simulations of 16 simulated clusters, including both very relaxed and unrelaxed systems and spanning a virial mass range of 5 x 10{sup 13} - 2 x 10{sup 15} h{sup -1} M-odot. We investigate effects of the residual subsonic gas motions on the hydrostatic estimates of mass profiles and concentrations of galaxy clusters. In agreement with previous studies, we find that the gas motions contribute up to approx5%-15% of the total pressure support in relaxed clusters with contribution increasing with the cluster-centric radius. The fractional pressure support is higher in unrelaxed systems. This contribution would not be accounted for in hydrostatic estimates of the total mass profile and would lead to systematic underestimate of mass. We demonstrate that total mass can be recovered accurately if pressure due to gas motions measured in simulations is explicitly taken into account in the equation of hydrostatic equilibrium. Given that the underestimate of mass is increasing at larger radii, where gas is less relaxed and contribution of gas motions to pressure is larger, the total density profile derived from hydrostatic analysis is more concentrated than the true profile. This may at least partially explain some high values of concentrations of clusters estimated from hydrostatic analysis of X-ray data.

  11. Transformation of a Water Slug in Free Fall Under the Conditions of Exposure to an Air Flow Orthogonal to the Direction of the Slug Motion

    NASA Astrophysics Data System (ADS)

    Volkov, R. S.; Zabelin, M. V.; Kuznetsov, G. V.; Strizhak, P. A.

    2016-07-01

    An experimental study has been made of the influence of an orthogonal (side) air flow propagating with a velocity to 5 m/s on the phases of transformation of a water slug with an initial volume of 0.05-0.5 liter in free fall from a height of 3 m. Use was made of Phantom V411 and Phantom Miro M310 high-speed video cameras and a Tema Automotive software system with the function of continuous tracking. The laws of retardation of the phases of transformation of the water slug from the instant of formation to that of formation of a droplet cloud under the action of the air flow orthogonal to the direction of the slug motion, and also of the deceleration, removal, and destruction of the droplets and fragments of water separating from the slug surface, have been established.

  12. Validation of AIRS Retrievals of CO2 via Comparison to In Situ Measurements

    NASA Technical Reports Server (NTRS)

    Olsen, Edward T.; Chahine, Moustafa T.; Chen, Luke L.; Jiang, Xun; Pagano, Thomas S.; Yung, Yuk L.

    2008-01-01

    Topics include AIRS on Aqua, 2002-present with discussion about continued operation to 2011 and beyond and background, including spectrum, weighting functions, and initialization; comparison with aircraft and FTIR measurements in Masueda (CONTRAIL) JAL flask measurements, Park Falls, WI FTIR, Bremen, GDF, and Spitsbergen, Norway; AIRS retrievals over addition FTIR sites in Darwin, AU and Lauder, NZ; and mid-tropospheric carbon dioxide weather and contribution from major surface sources. Slide titles include typical AIRS infrared spectrum, AIRS sensitivity for retrieving CO2 profiles, independence of CO2 solution with respect to the initial guess, available in situ measurements for validation and comparison, comparison of collocated V1.5x AIRS CO2 (N_coll greater than or equal to 9) with INTEX-NA and SPURT;

  13. Precise ground motion measurements to support multi-hazard analysis in Jakarta

    NASA Astrophysics Data System (ADS)

    Koudogbo, Fifamè; Duro, Javier; Garcia Robles, Javier; Abidin, Hasanuddin Z.

    2015-04-01

    Jakarta is the capital of Indonesia and is home to approximately 10 million people on the coast of the Java Sea. The Capital District of Jakarta (DKI) sits in the lowest lying areas of the basin. Its topography varies, with the northern part just meters above current sea level and lying on a flood plain. Subsequently, this portion of the city frequently floods. Flood events have been increasing in severity during the past decade. The February 2007 event inundated 235 Km2 (about 36%) of the city, by up to seven meters in some areas. This event affected more than 2.6 million people; the estimated financial and economic losses from this event amounted to US900 million [1][2]. Inundations continue to occur under any sustained rainfall conditions. Flood events in Jakarta are expected to become more frequent in coming years, with a shift from previously slow natural processes with low frequency to a high frequency process resulting in severe socio-economic damage. Land subsidence in Jakarta results in increased vulnerability to flooding due to the reduced gravitational capacity to channel storm flows to the sea and an increased risk of tidal flooding. It continues at increasingly alarming rates, principally caused by intensive deep groundwater abstraction [3]. Recent studies have found typical subsidence rates of 7.5-10 cm a year. In localized areas of north Jakarta subsidence in the range 15-25 cm a year is occurring which, if sustained, would result in them sinking to 4-5 m below sea level by 2025 [3]. ALTAMIRA INFORMATION, company specialized in ground motion monitoring, has developed GlobalSARTM, which combines several processing techniques and algorithms based on InSAR technology, to achieve ground motion measurements with millimetric precision and high accuracy [4]. Within the RASOR (Rapid Analysis and Spatialisation and Of Risk) project, ALTAMIRA INFORMATION will apply GlobalSARTM to assess recent land subsidence in Jakarta, based on the processing of Very High

  14. Measurement of Pressure Dependent Fluorescence Yield of Air: Calibration Factor for UHECR Detectors

    SciTech Connect

    Belz, J.W.; Burt, G.W.; Cao, Z.; Chang, F.Y.; Chen, C.C.; Chen, C.W.; Chen, P.; Field, C.; Findlay, J.; Huntemeyer, Petra; Huang, M.A.; Hwang, W.-Y.P.; Iverson, R.; Jones, B.F.; Jui, C.C.H.; Kirn, M.; Lin, G.-L.; Loh, E.C.; Maestas, M.M.; Manago, N.; Martens, K.; /Montana U. /Utah U. /Taiwan, Natl. Taiwan U. /SLAC /Rutgers U., Piscataway

    2005-07-06

    In a test experiment at the Final Focus Test Beam of the Stanford Linear Accelerator Center, the fluorescence yield of 28.5 GeV electrons in air and nitrogen was measured. The measured photon yields between 300 and 400 nm at 1 atm and 29 C are Y(760 Torr){sup air} = 4.42 {+-} 0.73 and Y(760 Torr){sup N{sub 2}} = 29.2 {+-} 4.8 photons per electron per meter. Assuming that the fluorescence yield is proportional to the energy deposition of a charged particle traveling through air, good agreement with measurements at lower particle energies is observed.

  15. Air ion measurements as a source of information about atmospheric aerosols

    NASA Astrophysics Data System (ADS)

    Hõrrak, Urmas; Mirme, Aadu; Salm, Jaan; Tamm, Eduard; Tammet, Hannes

    The mobility spectra of air ions recorded in the course of routine atmospheric electric measurements contain information about atmospheric aerosols. The mobility spectrum of air ions is correlated with the size spectrum of aerosol particles. Two procedures of conversion (and conversion errors) are considered in this paper assuming the steady state of charge distribution. The first procedure uses the fraction model of the aerosol particle size distribution and algebraic solution of the conversion problem. The second procedure uses the parametric KL model of the particle size distribution and the least square fitting of the mobility measurements. The procedures were tested using simultaneous side-by-side measurements of air ion mobilities and aerosol particle size distributions at a rural site during a monthly period. The comparison of results shows a promising agreement between the measured and calculated size spectra in the common size range. A supplementary information about nanometer particles was obtained from air ion measurements.

  16. 40 CFR 86.313-79 - Air flow measurement specifications; diesel engines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...; diesel engines. 86.313-79 Section 86.313-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.313-79 Air flow measurement specifications; diesel engines. (a) The air flow...

  17. 40 CFR 86.313-79 - Air flow measurement specifications; diesel engines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...; diesel engines. 86.313-79 Section 86.313-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.313-79 Air flow measurement specifications; diesel engines. (a) The air flow...

  18. 40 CFR 86.313-79 - Air flow measurement specifications; diesel engines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...; diesel engines. 86.313-79 Section 86.313-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.313-79 Air flow measurement specifications; diesel engines. (a) The air flow...

  19. 40 CFR 86.313-79 - Air flow measurement specifications; diesel engines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...; diesel engines. 86.313-79 Section 86.313-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.313-79 Air flow measurement specifications; diesel engines. (a) The air flow...

  20. An Inexpensive and Versatile Version of Kundt's Tube for Measuring the Speed of Sound in Air

    ERIC Educational Resources Information Center

    Papacosta, Pangratios; Linscheid, Nathan

    2016-01-01

    Experiments that measure the speed of sound in air are common in high schools and colleges. In the Kundt's tube experiment, a horizontal air column is adjusted until a resonance mode is achieved for a specific frequency of sound. When this happens, the cork dust in the tube is disturbed at the displacement antinode regions. The location of the…