Science.gov

Sample records for air sample analysis

  1. Sampling and analysis of terpenes in air. An interlaboratory comparison

    NASA Astrophysics Data System (ADS)

    Larsen, Bo; Bomboi-Mingarro, Teresa; Brancaleoni, Enzo; Calogirou, Aggelos; Cecinato, Angelo; Coeur, Cecile; Chatzinestis, Ioannis; Duane, Matthew; Frattoni, Massimiliano; Fugit, Jean-Luc; Hansen, Ute; Jacob, Veronique; Mimikos, Nikolaos; Hoffmann, Thorsten; Owen, Susan; Perez-Pastor, Rosa; Reichmann, Andreas; Seufert, Gunther; Staudt, Michael; Steinbrecher, Rainer

    An interlaboratory comparison on the sampling and analysis of terpenes in air was held within the framework of the BEMA (Biogenic Emissions in the Mediterranean Area) project in May 1995. Samples were drawn and analysed by 10 European laboratories from a dynamic artificial air generator in which five terpenes were present at low ng ℓ -1 levels and ozone varied between 8 and 125 ppbv. Significant improvements over previous inter-comparison exercises in the quality of results were observed. At the ozone mixing ratio of 8 ppbv a good agreement among laboratories was obtained for all test compounds with mean values close to the target concentration. At higher mixing ratios, ozone reduced terpene recoveries and decreased the precision of the measurements due to ozonolysis during sampling. For β-pinene this effect was negligible but for the more reactive compounds significant losses were observed in some laboratories ( cis-β-ocimene = trans-β-ocimene > linalool > d-limonene). The detrimental effect of ozone was significantly lower for the laboratories which removed ozone prior to sampling by scrubbers. Parallel sampling was carried out with a standardised sampler and each individual laboratory's own device. A good agreement between the two sets of results was obtained, clearly showing that the majority of laboratories used efficient sampling systems. Two different standard solutions were analysed by each laboratory. Only in a few cases did interference in the GC separation cause problems for the quantification of the terpenes (nonanal/linalool). However, making up of standards for the calibration of the analytical equipment (GC-MS or GC-FID) was pointed out as a source of error in some laboratories.

  2. Relative Humidity and its Effect on Sampling and Analysis of Agricultural Odorants in Air

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Source and ambient air sampling techniques used in agricultural air quality studies are seldom validated for the variability in the air matrix (temperature, dust levels, and relative humidity). In particular, relative humidity (RH) affects both field sampling and analysis of air samples. The objec...

  3. GAS CHROMATOGRAPHY/MATRIX ISOLATION - INFRARED SPECTROMETRY FOR AIR SAMPLE ANALYSIS

    EPA Science Inventory

    This report describes the application of gas chromatography/matrix- solation infrared (GC/MI-IR) spectrometry to the analysIs of environmental air sample extracts. Samples that were analyzed include extracts from woodsmoke-impacted air, XAD-2 blanks, indoor air, and carpet sample...

  4. Collection and analysis of NASA clean room air samples

    NASA Technical Reports Server (NTRS)

    Sheldon, L. S.; Keever, J.

    1985-01-01

    The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

  5. A STRINGENT COMPARISON OF SAMPLING AND ANALYSIS METHODS FOR VOCS IN AMBIENT AIR

    EPA Science Inventory

    A carefully designed study was conducted during the summer of 1998 to simultaneously collect samples of ambient air by canisters and compare the analysis results to direct sorbent preconcentration results taken at the time of sample collection. A total of 32 1-h sample sets we...

  6. A METHOD FOR THE SAMPLING AND ANALYSIS OF POLYCHLORINATED BIPHENYLS (PCBS) IN AMBIENT AIR

    EPA Science Inventory

    A method was developed for the sampling and analysis of polychlorinated biphenyls (PCBs) in air. An easily constructed, high-volume sampling system is employed with porous polyurethane foam as the collection medium. The sample is collected at the rate of 0.6 to 1.0 cu m per minut...

  7. COMPARISON OF FAST GC/TOFMS WITH METHOD TO-14 FOR ANALYSIS OF AMBIENT AIR SAMPLES

    EPA Science Inventory

    Field studies using portable gas chromatographs (PGC) to analyze volatile organic compounds in ambient air usually include, as reference standard method, the analysis of concurrent, collocated canister samples by EPA Method TO-14. Each laboratory analysis takes about an hour a...

  8. SAMPLING AND ANALYSIS OF PCDDS AND PCDFS IN STATIONARY SOURCE EMISSION AIR SAMPLES

    EPA Science Inventory

    Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzo-furans (PCDFs) are two classes of extremely toxic compounds produced and emitted into the environment as a result of combustion processes. lthough no standard method for sampling or analysis of PCDDs and PCDFs ...

  9. Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)

    NASA Technical Reports Server (NTRS)

    Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.

    1974-01-01

    The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.

  10. Identification of ambient air sampling and analysis methods for the 189 Title III air toxics

    SciTech Connect

    Mukund, R.; Kelly, T.J.; Gordon, S.M.; Hays, M.J.

    1994-12-31

    The state of development of ambient air measurement methods for the 189 Hazardous Air Pollution (HAPs) in Title 3 of the Clean Air Act Amendments was surveyed. Measurement methods for the HAPs were identified by reviews of established methods, and by literature searches for pertinent research techniques. Methods were segregated by their degree of development into Applicable, Likely, and Potential methods. This survey identified a total of 183 methods, applicable at varying degrees to ambient air measurements of one or more HAPs. As a basis for classifying the HAPs and evaluating the applicability of measurement methods, a survey of a variety of chemical and physical properties of the HAPs was also conducted. The results of both the methods and properties surveys were tabulated for each of the 189 HAP. The current state of development of ambient measurement methods for the 189 HAPs was then assessed from the results of the survey, and recommendations for method development initiatives were developed.

  11. Valveless sampling of ambient air for analysis by capillary gas chromatography

    SciTech Connect

    Stephens, E.R. )

    1989-09-01

    A method for the high resolution, high sensitivity analysis of polluted air for individual organic compounds is described. Samples collected from 50 mL of ambient air at 87 K (liquid argon) are injected without use of a valve into a silica capillary column which is then temperature programmed from {minus}30{degree}C to 180{degree}C. Hydrocarbons (4 to 10 carbons) as well as carbonyl compounds, chlorinated compounds and terpenes can be identified and quantified. The detection limit, not strongly dependent on carbon number, is estimated to be 0.3 ppbc in a 50 mL sample. Use of small samples eliminates the need to remove water vapor, a procedure which might jeopardize sample integrity.

  12. Electronic Nose and Use of Bags to Collect Odorous Air Samples in Meat Quality Analysis

    NASA Astrophysics Data System (ADS)

    Sala, G.; Masoero, G.; Battaglini, L. M.; Cornale, P.; Barbera, S.

    2009-05-01

    To test EN reliability and use of bags on meat, 17 bulls (one group of 9 and one of 8) fed similarly, except for a supplementary feedingstuff, were used. Samples were prepared according to the MCS protocol and repeated three times on different days for a total of 51 samples. Bags were used to collect raw and cooked meat air samples, and to test odour changes among samples analysed at different times. The first time analysis was performed immediately after collection then was repeated, 1 hour, 1 day and 1 week later. The Electronic Nose is very discriminant and clear differences were evident among raw, cooked and bags odorous profiles. The highest values were found in cooked samples and the broad range class (W5S) was the most representative. The EN also recognized the two tested feed treatments. In the cooked samples, all sensor responses decrease while time enhances, indicating a progressive chemical variation of the air composition in the bag, with a less correlation shown in the raw samples. When using bags, to avoid bias, is important to fix analysis in order to obtain useful results.

  13. A new analysis system for whole air sampling: description and results from 2013 SENEX

    NASA Astrophysics Data System (ADS)

    Lerner, B. M.; Gilman, J.; Dumas, M.; Hughes, D.; Jaksich, A.; Hatch, C. D.; Graus, M.; Warneke, C.; Apel, E. C.; Hornbrook, R. S.; Holloway, J. S.; De Gouw, J. A.

    2014-12-01

    Accurate measurement of volatile organic compounds (VOCs) in the troposphere is critical for the understanding of emissions and physical and chemical processes that can impact both air quality and climate. Airborne VOC measurements have proven especially challenging due to the requirement of both high sensitivity (pptv) and short sample collection times (≤15 s) to maximize spatial resolution and sampling frequency for targeted plume analysis. The use of stainless steel canisters to collect whole air samples (WAS) for post-flight analysis has been pioneered by the groups of D. Blake and E. Atlas [Blake et al., 1992; Atlas et al., 1993]. For the 2013 Southeast Nexus Study (SENEX), the NOAA ESRL CSD laboratory undertook WAS measurements for the first time. This required the construction of three new, highly-automated, and field-portable instruments designed to sample, analyze, and clean the canisters for re-use. Analysis was performed with a new custom-built gas chromatograph-mass spectrometer system. The instrument pre-concentrates analyte cryostatically into two parallel traps by means of a Stirling engine, a novel technique which obviates the need for liquid nitrogen to reach trapping temperatures of -175C. Here we present an evaluation of the retrieval of target VOC species from WAS canisters. We discuss the effects of humidity and sample age on the analyte, particularly upon C8+ alkane and aromatic species and biogenic species. Finally, we present results from several research flights during SENEX that targeted emissions from oil/natural gas production.

  14. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    SciTech Connect

    MULKEY, C.H.

    1999-07-06

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants.

  15. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1987-12-10

    An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  16. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, Katharine H.

    1990-01-01

    An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry.

  17. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1990-05-22

    An inertial impactor is designed which is to be used in an air sampling device for collection of respirable size particles in ambient air. The device may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  18. Greenhouse gas analysis of air samples collected onboard the CARIBIC passenger aircraft

    NASA Astrophysics Data System (ADS)

    Schuck, T. J.; Brenninkmeijer, C. A. M.; Slemr, F.; Xueref-Remy, I.; Zahn, A.

    2009-08-01

    CARIBIC (Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container) is a long-term atmospheric measurement program based on the use of a comprehensive scientific instrument package aboard a commercial passenger aircraft. In addition to real-time measurements, whole air sampling is performed regularly at cruising altitudes in the tropical middle troposphere and the extra-tropical UT/LS region. Air samples are analyzed for greenhouse gases, NMHCs, halocarbons, and trace gas isotopic composition. The routinely performed greenhouse gas analysis comprises gas chromatography measurements of CO2, CH4, N2O and SF6. The air sampling procedure, the GC system and its performance are described. Comparisons with similar systems employed in other laboratories and a comparison with results from a CO2 in-situ analyzer that is also part of the CARIBIC instrumentation are shown. In addition, the time series of CO2, obtained from the collection of 684 samples at latitudes between 30° N and 56° N on 21 round trips out of Germany to different destinations in Asia between November 2005 and October 2008, is presented. A time shift in the seasonal cycle of about one month was observed between the upper troposphere and the tropopause region. For two sets of return flights from Germany to the Philippines the relationship between the four greenhouse gases is briefly discussed.

  19. Air Sampling Filter

    NASA Technical Reports Server (NTRS)

    1980-01-01

    General Metal Works' Accu-Vol is a high-volume air sampling system used by many government agencies to monitor air quality for pollution control purposes. Procedure prevents possible test-invalidating contamination from materials other than particulate pollutants, caused by manual handling or penetration of windblown matter during transit, a cassette was developed in which the filter is sealed within a metal frame and protected in transit by a snap-on aluminum cover, thus handled only under clean conditions in the laboratory.

  20. Interlaboratory evaluation of cellulosic acid-soluble internal air sampling capsules for multi-element analysis.

    PubMed

    Andrews, Ronnee N; Feng, H Amy; Ashley, Kevin

    2016-01-01

    An interlaboratory study was carried out to evaluate the use of acid-soluble cellulosic air sampling capsules for their suitability in the measurement of trace elements in workplace atmospheric samples. These capsules are used as inserts to perform closed-face cassette sample collection for occupational exposure monitoring. The interlaboratory study was performed in accordance with NIOSH guidelines that describe statistical procedures for evaluating measurement accuracy of air monitoring methods. The performance evaluation materials used consisted of cellulose acetate capsules melded to mixed-cellulose ester filters that were dosed with multiple elements from commercial standard aqueous solutions. The cellulosic capsules were spiked with the following 33 elements of interest in workplace air monitoring: Ag, Al, As, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, In, K, La, Li, Mg, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Sr, Te, Ti, Tl, V, W, Y, Zn, Zr. The elemental loading levels were certified by an accredited provider of certified reference materials. Triplicates of media blanks and multielement-spiked capsules at three different elemental loadings were sent to each participating laboratory; the elemental loading levels were not revealed to the laboratories. The volunteer participating laboratories were asked to prepare the samples by acid dissolution and to analyze aliquots of extracted samples by inductively coupled plasma atomic emission spectrometry in accordance with NIOSH methods. It was requested that the study participants report their analytical results in units of μg of each target element per internal capsule sample. For the majority of the elements investigated (30 out of 33), the study accuracy estimates obtained satisfied the NIOSH accuracy criterion (A < 25%). This investigation demonstrates the utility of acid-soluble internal sampling capsules for multielement analysis by atomic spectrometry. PMID:26308974

  1. Greenhouse gas analysis of air samples collected onboard the CARIBIC passenger aircraft

    NASA Astrophysics Data System (ADS)

    Schuck, T. J.; Brenninkmeijer, C. A. M.; Slemr, F.; Xueref-Remy, I.; Zahn, A.

    2009-03-01

    CARIBIC (Civil Aircraft for the Regular Investigation of the Atmosphere Based on an Instrument Container) is a long-term atmospheric measurement program based on the use of a comprehensive scientific instrument package aboard a passenger aircraft. In addition to real time measurements, whole air sampling is performed regularly at cruising altitude in the upper troposphere and the extra-tropical UT/LS region. Air samples are analysed for greenhouse gases, NMHCs, halocarbons, and isotopic composition. The routinely performed greenhouse gas analysis comprises gas chromatography measurements of CO2, CH4, N2O and SF6. The sampling procedure, the GC system used for greenhouse gas analysis and its performance are described. Comparisons with other laboratories have shown good agreement of results as has a comparison with results from a CO2 in-situ analyser that is also part of the CARIBIC instrumentation. The timeseries of CO2 obtained from the collection of 684 samples at latitudes between 30° N and 56° N on 21 roundtrips out of Germany to different destinations in Asia between November 2005 and October 2008 is shown. A timeshift in the seasonal cyle of about one month was observed between the upper troposphere and the tropopause region. For two sets of return flights from Germany to the Philippines the relations between the four greenhouse gases CO2, CH4, N2O and SF6 are discussed in more detail. Distinct seasonal changes in the correlation between CH4 and CO2 are observed.

  2. Field evaluation of sampling and analysis for organic pollutants in indoor air. Project summary

    SciTech Connect

    Chuang, J.C.; Mack, G.A.; Stockrahm, J.W.; Hannan, S.W.; Bridges, C.

    1988-09-01

    The objectives of the study were to determine the feasibility of the use of newly developed indoor air samplers in residential indoor air sampling and to evaluate methodology for characterization of the concentrations of polynuclear aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in residential air.

  3. Sampling and analysis of trace-organic constituents in ambient and workplace air at coal-conversion facilities

    SciTech Connect

    Flotard, R D

    1980-07-01

    A review of the recent literature reveals that current sampling procedures involve the use of glass fiber filters for particulate-sorbed organics and sorbent resins such as Tenax GC and XAD-2 for vapor-phase organics. Ultra trace-organic analysis of air pollutants or particulates may require the collection of a large (1000 to 3000 m/sup 3/) sample by a high volume air sampler. Personal air sampling requires a smaller (approx. = 0.5 m/sup 3/) and a portable collection apparatus. Trapped organic chemicals are recovered by solvent extraction or thermal desorption of the collector. Recovered organics are separated by using liquid chromatography or gas chromatography and are identified by ultraviolet or fluorescence spectroscopy, gas chromatography, or mass spectrometry. For quantification, standards are added to the air stream during sampling or to the filter or resin following sampling. Analysis of the requirement for air sampling in and around coal conversion plants, coupled with the findings of the literature review, indicates that a combined particulate-filter and solvent-extractable-resin sampling unit should be used to collect both particulate-sorbed organics and vapor-phase organics from workplace or ambient plant air. Such a sampler was developed for stationary, moderate-to-high-volume air sampling. Descriptions of the sampler are provided together with sampling efficiency information and recommendations for a sampling procedure.

  4. Elemental analysis of cellular samples by in-air micro-PIXE

    NASA Astrophysics Data System (ADS)

    Ishii, K.; Sugimoto, A.; Tanaka, A.; Satoh, T.; Matsuyama, S.; Yamazaki, H.; Akama, C.; Amartivan, T.; Endoh, H.; Oishi, Y.; Yuki, H.; Sugihara, S.; Satoh, M.; Kamiya, T.; Sakai, T.; Arakawa, K.; Saidoh, M.; Oikawa, S.

    2001-07-01

    We developed a micro-PIXE system for the analysis of frozen cellular samples at atmospheric pressure under helium gas cooling. We analyzed bovine aortic endothelial (BAE) cells previously cultured in a medium containing bromodeoxyuridine (BrdU). It is known that these cells take BrdU into their nuclei at the S phase of their metabolic cycle. We examined the Br uptake for incubation times of 6, 12 and 24 h, respectively. The Br maps showed an accumulation in the nuclei and the Br concentration was found strongly dependent on the incubation time. We have demonstrated that in-air micro-PIXE analysis is a relevant technique for examining the molecular uptake in cells.

  5. Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air.

    PubMed

    Attari, Seyed Ghavameddin; Bahrami, Abdolrahman; Shahna, Farshid Ghorbani; Heidari, Mahmoud

    2014-01-01

    A green, environmental friendly and sensitive method for determination of volatile organohalogen compounds was described in this paper. The method is based on a homemade sol-gel single-walled carbon nanotube/silica composite coated solid-phase microextraction to develop for sampling and analysis of Carbon tetrachloride, Benzotrichloride, Chloromethyl methyl ether and Trichloroethylene in air. Application of this method was investigated under different laboratory conditions. Predetermined concentrations of each analytes were prepared in a home-made standard chamber and the influences of experimental parameters such as temperature, humidity, extraction time, storage time, desorption temperature, desorption time and the sorbent performance were investigated. Under optimal conditions, the use of single-walled carbon nanotube/silica composite fiber showed good performance, high sensitive and fast sampling of volatile organohalogen compounds from air. For linearity test the regression correlation coefficient was more than 98% for analyte of interest and linear dynamic range for the proposed fiber and the applied Gas Chromatography-Flame Ionization Detector technique was from 1 to 100 ngmL(-1). Method detection limits ranged between 0.09 to 0.2 ngmL(-1) and method quantification limits were between 0.25 and 0.7 ngmL(-1). Single-walled carbon nanotube/silica composite fiber was highly reproducible, relative standard deviations were between 4.3 to 11.7 percent. PMID:25279223

  6. FIELD EVALUATION OF SAMPLING AND ANALYSIS FOR ORGANIC POLLUTANTS IN INDOOR AIR

    EPA Science Inventory

    The objectives of the study were to determine the feasibility of the use of newly developed indoor air samplers in residential indoor air sampling and to evaluate methodology for characterization of the concentrations of polynuclear aromatic hydrocarbons (PAH), PAH derivatives, a...

  7. Report on sampling and analysis of ambient air at the central waste complex

    SciTech Connect

    Stauffer, M., Fluor Daniel Hanford

    1997-02-13

    Over 160 ambient indoor air samples were collected from warehouses at the Central Waste Complex used for the storage of low- level radioactive and mixed wastes. These grab (SUMMA) samples were analyzed by gas chromatography-mass spectrometry using a modified EPA TO-14 procedure. The data from this survey suggest that several buildings had elevated concentrations of volatile organic compounds.

  8. Field evaluation of sampling and analysis for organic pollutants in indoor air

    SciTech Connect

    Chuang, J.C.; Mack, G.A.; Stockrahm, J.W.; Hannan, S.W.; Bridges, C.

    1988-08-01

    The objectives of the study were to determine the feasibility of the use of newly developed indoor air samplers in residential indoor air sampling and to evaluate methodology for characterization of the concentrations of polynuclear aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in residential air. Residential air sampling was conducted in Columbus, Ohio during the winter of 1986/87. The PAH derivatives were found at much lower levels than their parent PAH. Higher average indoor levels of all but three target compounds were found compared to outdoor levels. The higher outdoor levels of these three compounds (naphthalene dicarboxylic acid anhydride, pyrene dicarboxylic acid anhydride, and 2-nitrofluoranthene) are probably due to atmospheric transformation. Cigarette smoking was identified as the most-significant contributor to indoor levels of PAH and PAH derivatives. Homes with gas-heating systems appeared to have higher pollutant levels compared to homes with electric-heating systems.

  9. Volatile N-nitrosamines in environmental tobacco smoke: Sampling, analysis, emission factors, and indoor air exposures

    SciTech Connect

    Mahanama, K.R.R.; Daisey, J.M.

    1996-05-01

    A more convenient sampling and analysis method for the volatile N-nitrosamines (VNA) in environmental tobacco smoke (ETS), using commercially available Thermosorb/N cartridges, was developed and validated. Using the method, emission factors for the two major VNA in ETS were determined in a room-sized environmental chamber for six commercial cigarette brands, which together accounted for 62.5% of the total market in California in 1990. The average emission factors were 565{+-}115 and 104{+-}20 ng per cigarette for N-nitrosodimethylamine and N-nitrosopyrrolidine, respectively. The emission factors were used to estimate VNA exposures from ETS in a typical office building and an average residence. Indoor concentrations of N,N-dimethylnitrosamine from ETS for these modeled scenarios were less than 10% of the reported median outdoor concentration. This median outdoor concentration, however, includes many measurements made in source-dominated areas and may be considerably higher than one based on more representative sampling of outdoor air. 35 refs., 4 tabs.

  10. ANALYSIS OF VOCS IN AMBIENT AIR USING MULTISORBENT PACKINGS FOR VOC ACCUMULATION AND SAMPLE DRYING

    EPA Science Inventory

    Solid multisorbent packings have been characterized for trapping and release efficiency of trace (10-20 ppbv in humidified zero air) volatile organic compounds (VOCs). he use of a two-stage trapping system reduces sample water content typically by more than 95.5% while maintainin...

  11. Report on sampling and analysis of exhaust air at the 221-T and 2706-T buildings

    SciTech Connect

    Stauffer, M.

    1997-09-22

    This report presents analytical results from exhaust air samples collected at stacks 221-T and 2706-T of the T-Plant. The samples were collected with SUMMA canisters over a 24 hour interval and were analyzed by gas chromatography-mass spectrometry using a modified EPA TO-14 procedure. The data suggest that the buildings had generally low concentrations of volatile organic compounds (< 40 ppbv). However, samples from building 2706-T did have significant amounts of non-target higher-boiling hydrocarbons, probably from a petroleum destination fraction.

  12. The classification of the patients with pulmonary diseases using breath air samples spectral analysis

    NASA Astrophysics Data System (ADS)

    Kistenev, Yury V.; Borisov, Alexey V.; Kuzmin, Dmitry A.; Bulanova, Anna A.

    2016-08-01

    Technique of exhaled breath sampling is discussed. The procedure of wavelength auto-calibration is proposed and tested. Comparison of the experimental data with the model absorption spectra of 5% CO2 is conducted. The classification results of three study groups obtained by using support vector machine and principal component analysis methods are presented.

  13. Unmanned platform for long-range remote analysis of volatile compounds in air samples.

    PubMed

    da Costa, Eric T; Neves, Carlos A; Hotta, Guilherme M; Vidal, Denis T R; Barros, Marcelo F; Ayon, Arturo A; Garcia, Carlos D; do Lago, Claudimir Lucio

    2012-09-01

    This paper describes a long-range remotely controlled CE system built on an all-terrain vehicle. A four-stroke engine and a set of 12-V batteries were used to provide power to a series of subsystems that include drivers, communication, computers, and a capillary electrophoresis module. This dedicated instrument allows air sampling using a polypropylene porous tube, coupled to a flow system that transports the sample to the inlet of a fused-silica capillary. A hybrid approach was used for the construction of the analytical subsystem combining a conventional fused-silica capillary (used for separation) and a laser machined microfluidic block, made of PMMA. A solid-state cooling approach was also integrated in the CE module to enable controlling the temperature and therefore increasing the useful range of the robot. Although ultimately intended for detection of chemical warfare agents, the proposed system was used to analyze a series of volatile organic acids. As such, the system allowed the separation and detection of formic, acetic, and propionic acids with signal-to-noise ratios of 414, 150, and 115, respectively, after sampling by only 30 s and performing an electrokinetic injection during 2.0 s at 1.0 kV. PMID:22965708

  14. Evaluation of a modified sampling method for molecular analysis of air microflora.

    PubMed

    Lech, T; Ziembinska-Buczynska, A

    2015-01-01

    A serious issue concerning the durability of economically important materials for humans related to cultural heritage is the process of biodeterioration. As a result of this phenomenon, priceless works of art, documents, and old prints have undergone a process of decomposition caused by microorganisms. Therefore, it is important to constantly monitor the presence and diversity of microorganisms in exposition rooms and storage areas of historical objects. In addition, the use of molecular biology tools for conservation studies will enable detailed research as well as reduce the time needed to perform the analyses compared with using conventional methods related to microbiology and conservation. The aim of this study was to adapt the sampling indoor air method for direct DNA extraction from microorganisms, including evaluating the extracted DNA quality and concentration. The obtained DNA was used to study the diversity of mold fungi in indoor air using polymerase chain reaction-denaturing gradient gel electrophoresis in specific archives and museum environments. The research was conducted in 2 storage rooms of the National Archives in Krakow and in 1 exposition room of the Archaeological Museum in Krakow (Poland). PMID:25966086

  15. The lung cancer breath signature: a comparative analysis of exhaled breath and air sampled from inside the lungs

    NASA Astrophysics Data System (ADS)

    Capuano, Rosamaria; Santonico, Marco; Pennazza, Giorgio; Ghezzi, Silvia; Martinelli, Eugenio; Roscioni, Claudio; Lucantoni, Gabriele; Galluccio, Giovanni; Paolesse, Roberto; di Natale, Corrado; D'Amico, Arnaldo

    2015-11-01

    Results collected in more than 20 years of studies suggest a relationship between the volatile organic compounds exhaled in breath and lung cancer. However, the origin of these compounds is still not completely elucidated. In spite of the simplistic vision that cancerous tissues in lungs directly emit the volatile metabolites into the airways, some papers point out that metabolites are collected by the blood and then exchanged at the air-blood interface in the lung. To shed light on this subject we performed an experiment collecting both the breath and the air inside both the lungs with a modified bronchoscopic probe. The samples were measured with a gas chromatography-mass spectrometer (GC-MS) and an electronic nose. We found that the diagnostic capability of the electronic nose does not depend on the presence of cancer in the sampled lung, reaching in both cases an above 90% correct classification rate between cancer and non-cancer samples. On the other hand, multivariate analysis of GC-MS achieved a correct classification rate between the two lungs of only 76%. GC-MS analysis of breath and air sampled from the lungs demonstrates a substantial preservation of the VOCs pattern from inside the lung to the exhaled breath.

  16. The lung cancer breath signature: a comparative analysis of exhaled breath and air sampled from inside the lungs

    PubMed Central

    Capuano, Rosamaria; Santonico, Marco; Pennazza, Giorgio; Ghezzi, Silvia; Martinelli, Eugenio; Roscioni, Claudio; Lucantoni, Gabriele; Galluccio, Giovanni; Paolesse, Roberto; Di Natale, Corrado; D’Amico, Arnaldo

    2015-01-01

    Results collected in more than 20 years of studies suggest a relationship between the volatile organic compounds exhaled in breath and lung cancer. However, the origin of these compounds is still not completely elucidated. In spite of the simplistic vision that cancerous tissues in lungs directly emit the volatile metabolites into the airways, some papers point out that metabolites are collected by the blood and then exchanged at the air-blood interface in the lung. To shed light on this subject we performed an experiment collecting both the breath and the air inside both the lungs with a modified bronchoscopic probe. The samples were measured with a gas chromatography-mass spectrometer (GC-MS) and an electronic nose. We found that the diagnostic capability of the electronic nose does not depend on the presence of cancer in the sampled lung, reaching in both cases an above 90% correct classification rate between cancer and non-cancer samples. On the other hand, multivariate analysis of GC-MS achieved a correct classification rate between the two lungs of only 76%. GC-MS analysis of breath and air sampled from the lungs demonstrates a substantial preservation of the VOCs pattern from inside the lung to the exhaled breath. PMID:26559776

  17. Evaluation of sorbent materials for the sampling and analysis of phosphine, sulfuryl fluoride and methyl bromide in air.

    PubMed

    Magnusson, R; Rittfeldt, L; Åstot, C

    2015-01-01

    Phosphine (PH3), sulfuryl fluoride (SO2F2) and methyl bromide (CH3Br) are highly toxic chemical substances commonly used for fumigation, i.e., pest control with gaseous pesticides. Residues of fumigation agents constitute a health risk for workers affected, and therefore accurate methods for air sampling and analysis are needed. In this study, three commercial adsorbent tubes; Carbosieve SIII™, Air Toxics™ and Tenax TA™, were evaluated for sampling these highly volatile chemicals in air and their subsequent analysis by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). The breakthrough volume (BTV) of each fumigant was experimentally determined on the different adsorbents at concentrations at or above their permissible exposure limits, using a method based on frontal chromatography of generated fumigant atmospheres. Carbosieve SIII™, a molecular sieve possessing a very high specific area, proved to be a better adsorbent than both Air Toxics™ and Tenax TA™, resulting in at least a 4-fold increase of the BTV50%. BTV50% for Carbosieve SIII™ at 20°C was measured as 4.7L/g, 5.5L/g and 126L/g for phosphine, sulfuryl fluoride and methyl bromide, respectively, implying safe sampling volumes of 1.9L, 2.2L and 50L, respectively, for a commercial tube packed with 800mg Carbosieve SIII™. The temperature dependence of BTV was strong for Carbosieve SIII™, showing a reduction of 3-5%/°C in breakthrough volume within the range -20 to 40°C. Furthermore, although Carbosieve SIII™ reportedly has a higher affinity for water than most other adsorbents, relative humidity had only a moderate influence on the retention capacity of phosphine. Overall, the applicability of Carbosieve SIII™ adsorbent sampling in combination with TD-GC-MS analysis was demonstrated for highly volatile fumigants. PMID:25512126

  18. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING AIR SAMPLES FOR ANALYSIS OF POLAR PERSISTENT ORGANIC POLLUTANTS (SOP-5.13)

    EPA Science Inventory

    The method for extracting and preparing indoor and outdoor air samples for analysis of polar persistent organic pollutants is summarized in this SOP. It covers the preparation of samples that are to be analyzed by gas chromatography/mass spectrometry.

  19. Development of automated preparation system for isotopocule analysis of N2O in various air samples

    NASA Astrophysics Data System (ADS)

    Toyoda, Sakae; Yoshida, Naohiro

    2016-05-01

    Nitrous oxide (N2O), an increasingly abundant greenhouse gas in the atmosphere, is the most important stratospheric ozone-depleting gas of this century. Natural abundance ratios of isotopocules of N2O, NNO molecules substituted with stable isotopes of nitrogen and oxygen, are a promising index of various sources or production pathways of N2O and of its sink or decomposition pathways. Several automated methods have been reported to improve the analytical precision for the isotopocule ratio of atmospheric N2O and to reduce the labor necessary for complicated sample preparation procedures related to mass spectrometric analysis. However, no method accommodates flask samples with limited volume or pressure. Here we present an automated preconcentration system which offers flexibility with respect to the available gas volume, pressure, and N2O concentration. The shortest processing time for a single analysis of typical atmospheric sample is 40 min. Precision values of isotopocule ratio analysis are < 0.1 ‰ for δ15Nbulk (average abundances of 14N15N16O and 15N14N16O relative to 14N14N16O), < 0.2 ‰ for δ18O (relative abundance of 14N14N18O), and < 0.5 ‰ for site preference (SP; difference between relative abundance of 14N15N16O and 15N14N16O). This precision is comparable to that of other automated systems, but better than that of our previously reported manual measurement system.

  20. Air-Based Remediation Workshop - Section 1 Sampling And Analysis Revelant To Air-Based Remediation Technologies

    EPA Science Inventory

    Pursant to the EPA-AIT Implementing Arrangement 7 for Technical Environmental Collaboration, Activity 11 "Remediation of Contaminated Sites," the USEPA Office of International Affairs Organized a Force Air Remediation Workshop in Taipei to deliver expert training to the Environme...

  1. SAMPLING AND ANALYSIS FOR POLYCHLORINATED DIBENZO-P-DIOXINS AND DIBENZOFURANS IN AMBIENT AIR

    EPA Science Inventory

    A short-term study for determination of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in ambient air in Green Bay, Wisconsin, has been completed. eneral Metals Works PS-1 air samplers equipped with particle filters and polyurethane foam (PUF)...

  2. Emission of atmospheric pollutants out of Africa - Analysis of CARIBIC aircraft air samples

    NASA Astrophysics Data System (ADS)

    Thorenz, Ute R.; Baker, Angela K.; Schuck, Tanja; van Velthoven, Peter F. J.; Ziereis, Helmut; Brenninkmeijer, Carl A. M.

    2014-05-01

    Africa is the single largest continental source of biomass burning (BB) emissions. The burning African savannas and tropical forests are a source for a wide range of chemical species, which are important for global atmospheric chemistry, especially for the pristine Southern Hemisphere. Emitted compounds include carbon monoxide (CO), nitrogen oxides (NOx), hydrocarbons, oxygenated hydrocarbons and particles. Deep convection over Central Africa transports boundary layer emissions to the free troposphere making aircraft-based observations useful for investigation of surface emissions and examination of transport and chemistry processes over Africa The CARIBIC project (Civil Aircraft for the Regular Investigation of the Atmosphere Based on an Instrument Container, www.caribic-atmosphere.com part of IAGOS www.iagos.org) is a long term atmospheric measurement program using an instrument container deployed aboard a Lufthansa Airbus A340-600 for a monthly sequence of long-distance passenger flights. Besides the online measurements mixing ratios of greenhouse gases and a suite of C2-C8 non methane hydrocarbons (NMHCs) are measured from flask samples collected at cruise altitude. During northern hemispheric winter 2010/2011 CARIBIC flights took place from Frankfurt to Cape Town and Johannesburg in South Africa. Several BB tracers like methane, CO and various NMHCs were found to be elevated over tropical Africa. Using tracer-CO- and tracer-NOy-correlations emissions were characterized. The NMHC-CO correlations show monthly changing slopes, indicating a change in burned biomass, major fire stage, source region and/or other factors influencing NMHC emissions. To expand our analysis of emission sources a source region data filter was used, based on backward trajectories calculated along the flight tracks. Taking all CARIBIC samples into account having backward trajectories to the African boundary layer the dataset was enlarged from 77 to 168 samples. For both datasets tracer

  3. Air sampling with solid phase microextraction

    NASA Astrophysics Data System (ADS)

    Martos, Perry Anthony

    There is an increasing need for simple yet accurate air sampling methods. The acceptance of new air sampling methods requires compatibility with conventional chromatographic equipment, and the new methods have to be environmentally friendly, simple to use, yet with equal, or better, detection limits, accuracy and precision than standard methods. Solid phase microextraction (SPME) satisfies the conditions for new air sampling methods. Analyte detection limits, accuracy and precision of analysis with SPME are typically better than with any conventional air sampling methods. Yet, air sampling with SPME requires no pumps, solvents, is re-usable, extremely simple to use, is completely compatible with current chromatographic equipment, and requires a small capital investment. The first SPME fiber coating used in this study was poly(dimethylsiloxane) (PDMS), a hydrophobic liquid film, to sample a large range of airborne hydrocarbons such as benzene and octane. Quantification without an external calibration procedure is possible with this coating. Well understood are the physical and chemical properties of this coating, which are quite similar to those of the siloxane stationary phase used in capillary columns. The log of analyte distribution coefficients for PDMS are linearly related to chromatographic retention indices and to the inverse of temperature. Therefore, the actual chromatogram from the analysis of the PDMS air sampler will yield the calibration parameters which are used to quantify unknown airborne analyte concentrations (ppb v to ppm v range). The second fiber coating used in this study was PDMS/divinyl benzene (PDMS/DVB) onto which o-(2,3,4,5,6- pentafluorobenzyl) hydroxylamine (PFBHA) was adsorbed for the on-fiber derivatization of gaseous formaldehyde (ppb v range), with and without external calibration. The oxime formed from the reaction can be detected with conventional gas chromatographic detectors. Typical grab sampling times were as small as 5 seconds

  4. Air Sampling System Evaluation Template

    2000-05-09

    The ASSET1.0 software provides a template with which a user can evaluate an Air Sampling System against the latest version of ANSI N13.1 "Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities". The software uses the ANSI N13.1 PIC levels to establish basic design criteria for the existing or proposed sampling system. The software looks at such criteria as PIC level, type of radionuclide emissions, physical state ofmore » the radionuclide, nozzle entrance effects, particulate transmission effects, system and component accuracy and precision evaluations, and basic system operations to provide a detailed look at the subsystems of a monitoring and sampling system/program. A GAP evaluation can then be completed which leads to identification of design and operational flaws in the proposed systems. Corrective measures can then be limited to the GAPs.« less

  5. Monitoring organic nitrogen species in the UT/LS - a new system for analysis of CARIBIC whole air samples

    NASA Astrophysics Data System (ADS)

    Sauvage, Carina; Thorenz, Ute; Baker, Angela; Brenninkmeijer, Carl; Williams, Jonathan

    2014-05-01

    The CARIBIC project is a unique program for long term and global scale monitoring of the atmosphere (http://www.caribic-atmospheric.com). An instrument container is installed monthly into a civil aircraft operated by Lufthansa (Airbus A 340-600) and makes atmospheric observations en route from Frankfurt, Germany to various destinations around the globe. In four to six long distance flights at a cruising altitude of 10 to 12 km online measurements of various atmospheric tracers are performed during the flight as well as whole air samples are taken with two different sampling units (116 samples in both glass and stainless steel canisters). These samples are routinely analyzed for greenhouse gases, non-methane hydrocarbons (NMHC) and halogenated compounds. Nitrogen containing compounds play various important roles in the atmosphere. Alkyl nitrates (RONO2) are products of the reaction of NMHC with OH and other oxidants in the presence of NO. They can provide information on the oxidative history of an air mass. Moreover they influence photolchemical ozone formation and act as a transport mechanism for reactive nitrogen. Less reactive nitrogen containing species such as HCN and acetonitrile are important markers for biomass burning, while organic amines are involved in gas to particle partitioning. Finally N2O is a long lived nitrogen containing gas important for the Earth's radiative budget. Regular measurements of such nitrogen compounds would therefore be a significant contribution to the CARIBIC data set. Especially for high altitude samples, in which the mixing ratios of many species are expected to be in the low ppt range, a highly sensitive method for analysis is required. Therefore a new system for measurement of nitrogen compounds has been built up, comprising a gas chromatograph (GC) using a nitrogen chemiluminescence detector (NCD). An important advantage of the NCD is that it is selective for nitrogen and equimolar. The nitrogen compounds are sequentially pre

  6. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF AIR SAMPLES FOR GC/MS ANALYSIS OF PESTICIDES (BCO-L-11.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for extracting and preparing an air sample consisting of a polyurethane foam (PUF) plug and Teflon-coated glass fiber filter (Pallflex T60A20) for analysis of pesticides. This procedure covers sample preparation for samples t...

  7. Air sampling in the workplace. Final report

    SciTech Connect

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC`s Regulatory Guide 8.25, Revision 1, ``Air sampling in the Workplace.`` That guide addresses air sampling to meet the requirements in NRC`s regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed.

  8. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING AIR SAMPLES FOR ANALYSIS OF NEUTRAL PERSISTENT ORGANIC POLLUTANTS (SOP-5.12)

    EPA Science Inventory

    The method is for extracting an indoor and outdoor air sample consisting of a quartz fiber filter and an XAD-2 cartridge for analysis of neutral persistent organic pollutants. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass...

  9. Volatile N-nitrosamines in Environment Tobacco Smoke: Sampling,Analysis, Smission Factors, and Indoor Air Exposures

    SciTech Connect

    Mahanama, K.R.R.; Daisey, J.M.

    1995-05-01

    A more convenient sampling and analysis method for the volatile N-nitrosamines (VNA) in ETS, using commercially available TherrnosorbIN cartridges, was developed and validated. Using the method, emission factors for the two major VNA in environmental tobacco smoke (ETS) were determined in a room-sized environmental chamber for six commercial cigarette brands, which together accounted for 62.5% of the total market in California in 1990. The average emission factors were 565 {+-} 115 and 104 {+-} 20 ng per cigarette for N-nitrosodimethylamine and N-nitrosopyrrolidine, respectively. The emission factors were used to estimate VNA exposures from ETS in a typical office building and an average residence. Indoor concentrations of N,N dimethylnitrosamine from ETS for these scenarios were less than 10% of the reported median outdoor concentration. This median outdoor concentration, however, includes many measurements made in source-dominated areas and may be considerably higher than one based on more representative sampling of outdoor air.

  10. Sampling, storage, and analysis of C2-C7 non-methane hydrocarbons from the US National Oceanic and Atmospheric Administration Cooperative Air Sampling Network glass flasks.

    PubMed

    Pollmann, Jan; Helmig, Detlev; Hueber, Jacques; Plass-Dülmer, Christian; Tans, Pieter

    2008-04-25

    An analytical technique was developed to analyze light non-methane hydrocarbons (NMHC), including ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane, n-hexane, isoprene, benzene and toluene from whole air samples collected in 2.5l-glass flasks used by the National Oceanic and Atmospheric Administration, Earth System Research Laboratory, Global Monitoring Division (NOAA ESRL GMD, Boulder, CO, USA) Cooperative Air Sampling Network. This method relies on utilizing the remaining air in these flasks (which is at below-ambient pressure at this stage) after the completion of all routine greenhouse gas measurements from these samples. NMHC in sample aliquots extracted from the flasks were preconcentrated with a custom-made, cryogen-free inlet system and analyzed by gas chromatography (GC) with flame ionization detection (FID). C2-C7 NMHC, depending on their ambient air mixing ratios, could be measured with accuracy and repeatability errors of generally < or =10-20%. Larger deviations were found for ethene and propene. Hexane was systematically overestimated due to a chromatographic co-elution problem. Saturated NMHC showed less than 5% changes in their mixing ratios in glass flask samples that were stored for up to 1 year. In the same experiment ethene and propene increased at approximately 30% yr(-1). A series of blank experiments showed negligible contamination from the sampling process and from storage (<10 pptv yr(-1)) of samples in these glass flasks. Results from flask NMHC analyses were compared to in-situ NMHC measurements at the Global Atmospheric Watch station in Hohenpeissenberg, Germany. This 9-months side-by-side comparison showed good agreement between both methods. More than 94% of all data comparisons for C2-C5 alkanes, isoprene, benzene and toluene fell within the combined accuracy and precision objectives of the World Meteorological Organization Global Atmosphere Watch (WMO-GAW) for NMHC measurements. PMID:18355832

  11. Evaluation of a sampling and analysis method for determination of polyhalogenated dibenzo-p-dioxins and dibenzofurans in ambient air

    SciTech Connect

    Harless, R.L.; Lewis, R.G.; McDaniel, D.D.; Gibson, J.F.; Dupuy, A.E.

    1992-01-01

    General Metals Works PS-1 PUF air samplers and an analytical method based on high resolution gas chromatography - high resolution mass spectrometry (HRGC-HRMS) were evaluated for determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), polybrominated dibenz-p-dioxins and dibenzofurans (PBDDs/PBDFs) and bromo/chloro dibenzo-p-dioxins and dibenzofurans (BCDDs/BCDFs) in ambient air. Dilute solutions of these compounds and (13)C-1,2,3,4-TCDD were used to spike the filters of PS-1 air samplers which were then operated 24 hrs to sample 350-400 cubic meter ambient air. After sampling, each quartz-fiber filter and polyurethane foam (PUF) were spiked with (13)C-12-labeled PCDD, PCDF, PBDD, and PBDF internal standards before separate Soxhlet extractions with benzene. The extracts were subjected to an acid/base clean-up procedure followed by clean-up on microcolumns of silica gel, alumina, and carbon and then analyzed by HRGC-HRMS. Results derived from the study indicated the PS-1 ambient air samplers and the analytical procedures were very efficient and that pg/cubic meter and sub-pg/cubic meter levels of total PCDDs/PCDFs, PBDDs/PBDFs, BCDDs/BCDFs, and 2,3,7,8-substituted congeners could be accurately measured.

  12. Evaluation of a sampling and analysis method for determination of polyhalogenated dibenzo-p-dioxins and dibenzofurans in ambient air

    SciTech Connect

    Harless, R.L.; Lewis, R.G.; McDaniel, D.D.; Gibson, J.F.; Dupuy, A.E.

    1991-01-01

    General Metals Works PS-1 PUF air samplers and an analytical method based on high resolution gas chromatography - high resolution mass spectrometry (HRGC-HRMS) were evaluated for determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), polybrominated dibenzo-p-dioxins and dibenzofurans (PBDDs/PBDFs) and bromo/chloro dibenzo-p-dioxins and dibenzofurans (BCDDs/BCDFs) in ambient air. Dilute solutions of these compounds and (13)C12-1,2,3,4-TCDD were used to spike the filters of PS-1 air samplers which were then operated 24 hrs to sample 350-400 cu m ambient air. After sampling, each quartz-fiber filter and polyurethane foam (PUF) were spiked with (13)C12-labeled PCDD, PCDF, PBDD, and PBDF internal standards before separate Soxhlet extractions with benzene. The extracts were subjected to an acid/base clean-up procedure followed by clean-up on microcolumns of silica gel, alumina, and carbon and then analyzed by HRGC-HRMS. Results derived from the study indicated the PS-1 ambient air samplers and the analytical procedures were very efficient and that pg/cu m and sub-pg/cu m levels of total PCDDs/PCDFs, PBDDs/PBDFs, BCDDs/BCDFs, and 2,3,7,8-substituted congeners could be accurately measured. Background levels of these compounds in the ambient air were also determined. Total PCDDs, PCDFs, TBDFs, and PeBDFs were detected in a low concentration range of 0.3 to 3.0 pg/cu m.

  13. Ultimate detectability of volatile organic compounds: how much further can we reduce their ambient air sample volumes for analysis?

    PubMed

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2012-10-01

    To understand the ultimately lowest detection range of volatile organic compounds (VOCs) in air, application of a high sensitivity analytical system was investigated by coupling thermal desorption (TD) technique with gas chromatography (GC) and time-of-flight (TOF) mass spectrometry (MS). The performance of the TD-GC/TOF MS system was evaluated using liquid standards of 19 target VOCs prepared in the range of 35 pg to 2.79 ng per μL. Studies were carried out using both total ion chromatogram (TIC) and extracted ion chromatogram (EIC) mode. EIC mode was used for calibration to reduce background and to improve signal-to-noise. The detectability of 19 target VOCs, if assessed in terms of method detection limit (MDL, per US EPA definition) and limit of detection (LOD), averaged 5.90 pg and 0.122 pg, respectively, with the mean coefficient of correlation (R(2)) of 0.9975. The minimum quantifiable mass of target analytes, when determined using real air samples by the TD-GC/TOF MS, is highly comparable to the detection limits determined experimentally by standard. In fact, volumes for the actual detection of the major aromatic VOCs like benzene, toluene, and xylene (BTX) in ambient air samples were as low as 1.0 mL in the 0.11-2.25 ppb range. It was thus possible to demonstrate that most target compounds including those in low abundance could be reliably quantified at concentrations down to 0.1 ppb at sample volumes of less than 10 mL. The unique sensitivity of this advanced analytical system can ultimately lead to a shift in field sampling strategy with smaller air sample volumes facilitating faster, simpler air sampling (e.g., use of gas syringes rather than the relative complexity of pumps or bags/canisters), with greatly reduced risk of analyte breakthrough and minimal interference, e.g., from atmospheric humidity. The improved detection limits offered by this system can also enhance accuracy and measurement precision. PMID:22934885

  14. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  15. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 9 2014-07-01 2014-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  16. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  17. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  18. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  19. Air-Assisted Liquid Liquid-Microextraction for the Analysis of Fungicides from Environmental Water and Juice Samples.

    PubMed

    Wu, Shiju; Jin, Tingting; Cheng, Jing; Zhou, Hongbin; Cheng, Min

    2015-07-01

    In this work, a rapid method based on air-assisted liquid liquid microextraction (AALLME) was developed for the determination of three fungicides (azoxystrobin, diethofencarb and pyrimethanil) in water and juice samples. A narrow-neck glass tube was made to facilitate collection of the low-density extractant. The mixture of extractant and sample solution is rapidly sucked into a 5-mL glass syringe and then is injected into the narrow-neck glass tube and the procedure is repeated six times. A homogeneous solution was formed and then with the continuous injection of air by a 20-mL glass syringe, phase separation happened and the extractant was collected on the top of the sample solution. No centrifugation separation step was involved. It took only 90 s to complete the pretreatment process. The influence of main factors on the extraction efficiency is studied. Under optimal conditions, enrichment factors for the three fungicides varied from 145 to 178. The limits of detection for azoxystrobin, diethofencarb and pyrimethanil were 0.08, 0.16 and 0.25 µg L(-1), respectively. Reasonable relative recoveries were varied from 72.3 to 108.0%. And satisfactory intra-assay (5.3-6.2%, n = 6) and inter-assay (6.8-9.3%, n = 6) precision illustrated good performance of the analytical procedure. PMID:25355900

  20. Acid-Soluble Internal Capsules for Closed-Face Cassette Elemental Sampling and Analysis of Workplace Air

    PubMed Central

    Harper, Martin; Ashley, Kevin

    2013-01-01

    Airborne particles that are collected using closed-face filter cassettes (CFCs), which are used widely in the sampling of workplace aerosols, can deposit in places other than on the filter and thereby may not be included in the ensuing analysis. A technique for ensuring that internal non-filter deposits are included in the analysis is to collect airborne particles within an acid-soluble internal capsule that, following sampling, can be dissolved along with the filter for subsequent elemental analysis. An interlaboratory study (ILS) was carried out to evaluate the use of cellulosic CFC capsule inserts for their suitability in the determination of trace elements in airborne samples. The ILS was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Performance evaluation materials consisted of prototype cellulose acetate capsules attached to mixed-cellulose ester filters. Batches of capsules were dosed with Pb-containing materials (standard aqueous solutions, and certified reference material soil and paint). Also, aerosol samples containing nine target analyte elements (As, Cd, Co, Cr, Cu, Fe, Pb, Mn, and Ni) were generated using a multiport sampler; various concentrations and sampling times were employed to yield samples fortified at desired loading levels. Triplicates of spiked capsules at three different loadings were conveyed to each volunteer laboratory; loading levels were unknown to the participants. The laboratories were asked to prepare the samples by acid dissolution and to analyze aliquots of extracted samples by atomic spectrometry in accordance with applicable ASTM International Standards. Participants were asked to report their results in units of μg of each target element per sample. For the elements investigated, interlaboratory precision and recovery estimates from the participating laboratories demonstrated the utility of the

  1. 24-HOUR DIFFUSIVE SAMPLING OF TOXIC VOCS IN AIR ONTO CARBOPACK X SOLID ADSORBENT FOLLOWED BY THERMAL DESORPTION/GC/MS ANALYSIS - LABORATORY STUDIES

    EPA Science Inventory

    Diffusive sampling of a mixture of 42 volatile organic compounds (VOCs) in humidified, purified air onto the solid adsorbent Carbopack X was evaluated under controlled laboratory conditions. The evaluation included variations in sample air temperature, relative humidity, and ozon...

  2. Optimisation of sorbent trapping and thermal desorption-gas chromatography-mass spectrometric conditions for sampling and analysis of hydrogen cyanide in air.

    PubMed

    Juillet, Yannick; Le Moullec, Sophie; Bégos, Arlette; Bellier, Bruno

    2005-06-01

    Among the chemicals belonging to the schedules of the Chemical Weapons Convention (CWC), sampling and analysis of highly volatile compounds such as hydrogen cyanide (HCN) require special consideration. The latter is present in numerous old chemical weapons that are stockpiled awaiting destruction in Northeastern France: thus, sampling on stockpile area and subsequent verification of HCN levels is compulsory to ensure safety of workers on these areas. The ability of several commercial sorbents to trap hydrogen cyanide at various concentration levels and in various humidity conditions, was evaluated. Furthermore, thermal desorption of the corresponding samples, followed by analysis by gas chromatography-mass spectrometry was also optimised. Carbosieve S-III, a molecular sieve possessing a very high specific area, proved the most efficient sorbent for HCN sampling in all conditions tested. Conversely, the presented results show that Tenax, albeit generally considered as the reference sorbent for air monitoring and analysis of CWC-related chemicals, is not suitable for HCN trapping. PMID:15912249

  3. Minimisation of artefact formation of dimethyl disulphide during sampling and analysis of methanethiol in air using solid sorbent materials.

    PubMed

    Andersen, Kristin Barkve; Hansen, Michael Jørgen; Feilberg, Anders

    2012-07-01

    Methanethiol (MT) is a potent odorant that can be difficult to measure due to its high volatility and reactivity; it easily reacts to form dimethyl disulphide (DMDS) during sampling and/or analysis. This paper focuses on finding an optimal method for sampling and measuring MT with minimum artefact formation using sorbent materials and a thermal desorption-gas chromatography-mass spectrometry method (TD-GC-MS). Experiments were conducted to identify suitable sorbent materials and tubes for analysis. Breakthrough, desorption rate, the effects of storage and desorption temperatures were investigated and different drying methods were established with respect to quantitative sampling and formation of DMDS. Proton-transfer-reaction mass spectrometry (PTR-MS) was used in the development of the method and was an especially useful tool for determination of breakthrough. The results show that glass tubes packed with silica gel for pre-concentration of MT before analysis with TD-GC-MS give the best results. In addition, a combination of Tenax TA and carbonised molecular sieve or Tenax TA cooled to ≤0°C gives acceptable results. 80°C was found to be the optimal desorption temperature. For all the sampling methods tested, storage conditions were observed to be very critical for transformation of MT. Room temperature storage should be limited to few minutes and, in general, tubes should be kept at 0°C or lower during storage. PMID:22658137

  4. East Mountain Area 1995 air sampling results

    SciTech Connect

    Deola, R.A.

    1996-09-01

    Ambient air samples were taken at two locations in the East Mountain Area in conjunction with thermal testing at the Lurance Canyon Burn Site (LCBS). The samples were taken to provide measurements of particulate matter with a diameter less than or equal to 10 micrometers (PM{sub 10}) and volatile organic compounds (VOCs). This report summarizes the results of the sampling performed in 1995. The results from small-scale testing performed to determine the potentially produced air pollutants in the thermal tests are included in this report. Analytical results indicate few samples produced measurable concentrations of pollutants believed to be produced by thermal testing. Recommendations for future air sampling in the East Mountain Area are also noted.

  5. Near-IR laser-based spectrophotometer for comparative analysis of isotope content of CO{sub 2} in exhale air samples

    SciTech Connect

    Stepanov, E V; Glushko, A N; Kasoev, S G; Koval', A V; Lapshin, D A

    2011-12-31

    We present a laser spectrophotometer aimed at high-accuracy comparative analysis of content of {sup 12}CO{sub 2} and {sup 13}CO{sub 2} isotope modifications in the exhale air samples and based on a tunable near-IR diode laser (2.05 {mu}m). The two-channel optical scheme of the spectrophotometer and the special digital system for its control are described. An algorithm of spectral data processing aimed at determining the difference in the isotope composition of gas mixtures is proposed. A few spectral regions (near 4880 cm{sup -1}) are determined to be optimal for analysis of relative content of {sup 12}CO{sub 2} and {sup 13}CO{sub 2} in the exhale air. The use of the proposed spectrophotometer scheme and the developed algorithm makes the results of the analysis less susceptible to the influence of the interference in optical elements, to the absorption in the open atmosphere, to the slow drift of the laser pulse envelope, and to the offset of optical channels. The sensitivity of the comparative analysis of the isotope content of CO{sub 2} in exhale air samples, achieved using the proposed scheme, is estimated to be nearly 0.1 Per-Mille-Sign .

  6. Solid waste transuranic storage and assay facility indoor air sampling

    SciTech Connect

    Pingel, L.A., Westinghouse Hanford

    1996-08-20

    The purpose of the study is to collect and analyze samples of the indoor air at the Transuranic Storage and Assay Facility (TRUSAF), Westinghouse Hanford. A modified US EPA TO-14 methodology, using gas chromatography/mass spectrography, may be used for the collection and analysis of the samples. The information obtained will be used to estimate the total release of volatile organic compounds from TRUSAF to determine the need for air emmission permits.

  7. Field Air Sampling and Simultaneous Chemical and Sensory Analysis of Livestock Odorants with Sorbent Tube GC-MS/Olfactometry

    NASA Astrophysics Data System (ADS)

    Zhang, Shicheng; Cai, Lingshuang; Koziel, Jacek A.; Hoff, Steven; Clanton, Charles; Schmidt, David; Jacobson, Larry; Parker, David; Heber, Albert

    2009-05-01

    Characterization and quantification of livestock odorants is one of the most challenging analytical tasks because odor-causing gases are very reactive, polar and often present at very low concentrations in a complex matrix of less important or irrelevant gases. The objective of this research was to develop a novel analytical method for characterization of the livestock odorants including their odor character, odor intensity, and hedonic tone and to apply this method for quantitative analysis of the key odorants responsible for livestock odor. Sorbent tubes packed with Tenax TA were used for field sampling. The automated one-step thermal desorption module coupled with multidimensional gas chromatography-mass spectrometry/olfactometry system was used for simultaneous chemical and odor analysis. Fifteen odorous VOCs and semi-VOCs identified from different livestock species operations were quantified. Method detection limits ranges from 40 pg for skatole to 3590 pg for acetic acid. In addition, odor character, odor intensity and hedonic tone associated with each of the target odorants are also analyzed simultaneously. We found that the mass of each VOCs in the sample correlates well with the log stimulus intensity. All of the correlation coefficients (R2) are greater than 0.74, and the top 10 correlation coefficients were greater than 0.90.

  8. Testing of Continuous Sampling Air-ICP and Mercury Systems as Continuous Emission Monitors at the Diagnostic Instrumentation and Analysis Laboratory

    SciTech Connect

    D.P. Baldwin; S.J. Bajic; D.E. Eckels; D.S. Zamzow; G.P. Miller; S. Tao; C.A. Waggoner

    2001-03-15

    This report has been prepared to document the performance of the continuous sampling reduced-pressure air-ICP-AES (inductively coupled plasma--atomic emission spectroscopy) and mercury-monitor systems developed by Ames Laboratory for use as continuous emission monitors (CEM). This work was funded by the U. S. Department of Energy, Office of Environmental Management, Office of Science and Technology, through the Mixed Waste Focus Area. The purpose of the project is to develop instrumentation and methods for spectroscopic field monitoring applications. During FY00 this included continued work on the development of the continuous sample introduction system and the multi-frequency AOTF-echelle spectrometer, used in conjunction with the reduced-pressure air-ICP-AES system as a multi-metal CEM. The assembly, development, and testing of an echelle spectrometer system for the detection of mercury (Hg) by atomic absorption was also completed during FY00. The continuous sampling system and the multi-metal air-ICP and mercury-monitor CEM systems were tested at Mississippi State University at the Diagnostic Instrumentation and Analysis Laboratory (DIAL) at the end of FY00. This report describes the characteristics and performance of these systems, and the results of the field tests performed at DIAL.

  9. Evaluating Radionuclide Air Emission Stack Sampling Systems

    SciTech Connect

    Ballinger, Marcel Y.

    2002-12-16

    The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R&D) facilities for the U.S. Department of Energy at the Hanford Site, Washington. These facilities are subject to Clean Air Act regulations that require sampling of radionuclide air emissions from some of these facilities. A revision to an American National Standards Institute (ANSI) standard on sampling radioactive air emissions has recently been incorporated into federal and state regulations and a re-evaluation of affected facilities is being performed to determine the impact. The revised standard requires a well-mixed sampling location that must be demonstrated through tests specified in the standard. It also carries a number of maintenance requirements, including inspections and cleaning of the sampling system. Evaluations were performed in 2000 – 2002 on two PNNL facilities to determine the operational and design impacts of the new requirements. The evaluation included inspection and cleaning maintenance activities plus testing to determine if the current sampling locations meet criteria in the revised standard. Results show a wide range of complexity in inspection and cleaning activities depending on accessibility of the system, ease of removal, and potential impact on building operations (need for outages). As expected, these High Efficiency Particulate Air (HEPA)-filtered systems did not show deposition significant enough to cause concerns with blocking of the nozzle or other parts of the system. The tests for sampling system location in the revised standard also varied in complexity depending on accessibility of the sample site and use of a scale model can alleviate many issues. Previous criteria to locate sampling systems at eight duct diameters downstream and two duct diameters upstream of the nearest disturbances is no guarantee of meeting criteria in the revised standard. A computational fluid dynamics model was helpful in understanding flow and

  10. Combination syringe provides air-free blood samples

    NASA Technical Reports Server (NTRS)

    Pool, S. L.

    1970-01-01

    Standard syringe and spinal needle are combined in unique manner to secure air-free blood samples. Combination syringe obtains air free samples because air bubbles become insignificant when samples greater than 1 cc are drawn.

  11. Application of a high surface area solid-phase microextraction air sampling device: collection and analysis of chemical warfare agent surrogate and degradation compounds.

    PubMed

    Stevens, Michael E; Tipple, Christopher A; Smith, Philip A; Cho, David S; Mustacich, Robert V; Eckenrode, Brian A

    2013-09-17

    This work examines a recently improved, dynamic air sampling technique, high surface area solid-phase microextraction (HSA-SPME), developed for time-critical, high-volume sampling and analysis scenarios. The previously reported HSA-SPME sampling device, which provides 10-fold greater surface area compared to commercially available SPME fibers, allowed for an increased analyte uptake per unit time relative to exhaustive sampling through a standard sorbent tube. This sampling device has been improved with the addition of a type-K thermocouple and a custom heater control circuit for direct heating, providing precise (relative standard deviation ∼1%) temperature control of the desorption process for trapped analytes. Power requirements for the HSA-SPME desorption process were 30-fold lower than those for conventional sorbent-bed-based desorption devices, an important quality for a device that could be used for field analysis. Comparisons of the HSA-SPME device when using fixed sampling times for the chemical warfare agent (CWA) surrogate compound, diisopropyl methylphosphonate (DIMP), demonstrated that the HSA-SPME device yielded a greater chromatographic response (up to 50%) relative to a sorbent-bed method. Another HSA-SPME air sampling approach, in which two devices are joined in tandem, was also evaluated for very rapid, low-level, and representative analysis when using discrete sampling times for the compounds of interest. The results indicated that subparts per billion by volume concentration levels of DIMP were detectable with short sampling times (∼15 s). Finally, the tandem HSA-SPME device was employed for the headspace sampling of a CWA degradation compound, 2-(diisopropylaminoethyl) ethyl sulfide, present on cloth material, which demonstrated the capability to detect trace amounts of a CWA degradation product that is estimated to be less volatile than sarin. The rapid and highly sensitive detection features of this device may be beneficial in decision

  12. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF INDOOR AND OUTDOOR AIR SAMPLES FOR METAL, PESTICIDE, AND PAH ANALYSIS (F02)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures to be used for collecting, storing, and shipping indoor air samples to be analyzed for metals, pesticides, and polynuclear aromatic hydrocarbons (PAHs), and outdoor air samples to be analyzed for metals. A Black Box pumping u...

  13. A novel needle trap device with single wall carbon nanotubes sol-gel sorbent packed for sampling and analysis of volatile organohalogen compounds in air.

    PubMed

    Heidari, Mahmoud; Bahrami, Abdolrahman; Ghiasvand, Ali Reza; Shahna, Farshid Ghorbani; Soltanian, Ali Reza

    2012-11-15

    This paper describes a new approach that combines needle trap devices (NTDs) with a newly synthesized silanated nano material as sorbent for sampling and analysis of HVOCs in air. The sol-gel technique was used for preparation of the single wall carbon nanotube (SWCNT)/silica composite as sorbent, packed inside a 21-gauge NTD. Application of this method as an exhaustive sampler device was investigated under different laboratory conditions in this study. Predetermined concentrations of each analyte were prepared in a home-made standard chamber, and the effects of experimental parameters, such as temperature, humidity, sampling air flow rate, breakthrough volume and storage time on NTD, and the sorbent performance were investigated. The proposed NTD was used in two different modes and two different injection methods, and an NTD with a side hole, a narrow neck glass liner and syringe pump assisted injection of carrier gas were applied. The NTD packed with SWCNTs/silica composite was compared to the NTD packed with PDMS and also SPME with CAR/PDMS. For four compounds, LOD was 0.001-0.01 ng mL(-1), LOQ was 0.007-0.03 ng mL(-1), and the relative standard division for repeatability of method was 2.5-6.7%. The results show that the incorporation of NTD and SWCNTs/silica composite is a reliable and effective approach for the sampling and analysis of HVOCs in air. Coupling this system to GC-MS make it more sensitive and powerful technique. PMID:23158328

  14. Concepts for Environmental Radioactive Air Sampling and Monitoring

    SciTech Connect

    Barnett, J. Matthew

    2011-11-04

    Environmental radioactive air sampling and monitoring is becoming increasingly important as regulatory agencies promulgate requirements for the measurement and quantification of radioactive contaminants. While researchers add to the growing body of knowledge in this area, events such as earthquakes and tsunamis demonstrate how nuclear systems can be compromised. The result is the need for adequate environmental monitoring to assure the public of their safety and to assist emergency workers in their response. Two forms of radioactive air monitoring include direct effluent measurements and environmental surveillance. This chapter presents basic concepts for direct effluent sampling and environmental surveillance of radioactive air emissions, including information on establishing the basis for sampling and/or monitoring, criteria for sampling media and sample analysis, reporting and compliance, and continual improvement.

  15. EVALUATION OF A SAMPLING AND ANALYSIS METHOD FOR DETERMINATION OF POLYCHLORINATED DIBENZO-P-DIOXINS AND DIBENZOFURANS IN AMBIENT AIR

    EPA Science Inventory

    General Metals Works PS-1 PUF air samplers and an analytical method based on high esolution gas chromatography - high resolution mass spectrometry (HRGC-HRMS) were valuated for determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), polybrominated dibe...

  16. Passive Samplers for Investigations of Air Quality: Method Description, Implementation, and Comparison to Alternative Sampling Methods

    EPA Science Inventory

    This Paper covers the basics of passive sampler design, compares passive samplers to conventional methods of air sampling, and discusses considerations when implementing a passive sampling program. The Paper also discusses field sampling and sample analysis considerations to ensu...

  17. AIR Model Preflight Analysis

    NASA Technical Reports Server (NTRS)

    Tai, H.; Wilson, J. W.; Maiden, D. L.

    2003-01-01

    The atmospheric ionizing radiation (AIR) ER-2 preflight analysis, one of the first attempts to obtain a relatively complete measurement set of the high-altitude radiation level environment, is described in this paper. The primary thrust is to characterize the atmospheric radiation and to define dose levels at high-altitude flight. A secondary thrust is to develop and validate dosimetric techniques and monitoring devices for protecting aircrews. With a few chosen routes, we can measure the experimental results and validate the AIR model predictions. Eventually, as more measurements are made, we gain more understanding about the hazardous radiation environment and acquire more confidence in the prediction models.

  18. EVALUATION OF A METHOD FOR SAMPLING AND ANALYSIS OF NICOTINE AND POLYNUCLEAR AROMATIC HYDROCARBONS IN INDOOR AIR

    EPA Science Inventory

    A study was performed to determine whether one sampling system and one analytical method can be used to measure both polynuclear aromatic hydrocarbons (PAH) and nicotine. he PAH collection efficiencies for both XAD-2 and XAD-4 adsorbents are very similar, but the nicotine collect...

  19. Air Sampling Instruments for Evaluation of Atmospheric Contaminants. Fourth Edition.

    ERIC Educational Resources Information Center

    American Conference of Governmental Industrial Hygienists, Cincinnati, OH.

    This text, a revision and extension of the first three editions, consists of papers discussing the basic considerations in sampling air for specific purposes, sampler calibration, systems components, sample collectors, and descriptions of air-sampling instruments. (BT)

  20. A simple novel device for air sampling by electrokinetic capture

    DOE PAGESBeta

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A.

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of

  1. A simple novel device for air sampling by electrokinetic capture

    SciTech Connect

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A.

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the

  2. Presence of organophosphorus pesticide oxygen analogs in air samples

    PubMed Central

    Armstrong, Jenna L.; Fenske, Richard A.; Yost, Michael G.; Galvin, Kit; Tchong-French, Maria; Yu, Jianbo

    2012-01-01

    A number of recent toxicity studies have highlighted the increased potency of oxygen analogs (oxons) of several organophosphorus (OP) pesticides. These findings were a major concern after environmental oxons were identified in environmental samples from air and surfaces following agricultural spray applications in California and Washington State. This paper reports on the validity of oxygen analog measurements in air samples for the OP pesticide, chlorpyrifos. Controlled environmental and laboratory experiments were used to examine artificial formation of chlorpyrifos-oxon using OSHA Versatile Sampling (OVS) tubes as recommended by NIOSH method 5600. Additionally, we compared expected chlorpyrifos-oxon attributable to artificial transformation to observed chlorpyrifos-oxon in field samples from a 2008 Washington State Department of Health air monitoring study using non-parametric statistical methods. The amount of artificially transformed oxon was then modeled to determine the amount of oxon present in the environment. Toxicity equivalency factors (TEFs) for chlorpyrifos-oxon were used to calculate chlorpyrifos-equivalent air concentrations. The results demonstrate that the NIOSH-recommended sampling matrix (OVS tubes with XAD-2 resin) was found to artificially transform up to 30% of chlorpyrifos to chlorpyrifos-oxon, with higher percentages at lower concentrations (< 30 ng/m3) typical of ambient or residential levels. Overall, the 2008 study data had significantly greater oxon than expected by artificial transformation, but the exact amount of environmental oxon in air remains difficult to quantify with the current sampling method. Failure to conduct laboratory analysis for chlorpyrifos-oxon may result in underestimation of total pesticide concentration when using XAD-2 resin matrices for occupational or residential sampling. Alternative methods that can accurately measure both OP pesticides and their oxygen analogs should be used for air sampling, and a toxicity

  3. Presence of organophosphorus pesticide oxygen analogs in air samples

    NASA Astrophysics Data System (ADS)

    Armstrong, Jenna L.; Fenske, Richard A.; Yost, Michael G.; Galvin, Kit; Tchong-French, Maria; Yu, Jianbo

    2013-02-01

    A number of recent toxicity studies have highlighted the increased potency of oxygen analogs (oxons) of several organophosphorus (OP) pesticides. These findings were a major concern after environmental oxons were identified in environmental samples from air and surfaces following agricultural spray applications in California and Washington State. This paper reports on the validity of oxygen analog measurements in air samples for the OP pesticide, chlorpyrifos. Controlled environmental and laboratory experiments were used to examine artificial formation of chlorpyrifos-oxon using OSHA Versatile Sampling (OVS) tubes as recommended by NIOSH method 5600. Additionally, we compared expected chlorpyrifos-oxon attributable to artificial transformation to observed chlorpyrifos-oxon in field samples from a 2008 Washington State Department of Health air monitoring study using non-parametric statistical methods. The amount of artificially transformed oxon was then modeled to determine the amount of oxon present in the environment. Toxicity equivalency factors (TEFs) for chlorpyrifos-oxon were used to calculate chlorpyrifos-equivalent air concentrations. The results demonstrate that the NIOSH-recommended sampling matrix (OVS tubes with XAD-2 resin) was found to artificially transform up to 30% of chlorpyrifos to chlorpyrifos-oxon, with higher percentages at lower concentrations (<30 ng m-3) typical of ambient or residential levels. Overall, the 2008 study data had significantly greater oxon than expected by artificial transformation, but the exact amount of environmental oxon in air remains difficult to quantify with the current sampling method. Failure to conduct laboratory analysis for chlorpyrifos-oxon may result in underestimation of total pesticide concentration when using XAD-2 resin matrices for occupational or residential sampling. Alternative methods that can accurately measure both OP pesticides and their oxygen analogs should be used for air sampling, and a toxicity

  4. Operational air sampling report, July--December 1991

    SciTech Connect

    Lyons, C.L.

    1992-11-01

    Air sampling is one of the more useful ways of assessing the effectiveness of operational radiation safety programs at the Nevada Test Site (NTS). Air sampling programs document NTS airborne radionuclide concentrations in various work locations and environments. These concentrations generally remain well below the Derived Air Concentration (DAC) values prescribed by the Department of Energy (DOE 5480.11, Attachment 1) or the Derived Concentration Guide (DCG) values prescribed by the Department of Energy DOE 5400.5, Chapter Ill. The Defense Nuclear Agency (DNA) tunnel complexes, Area 12 Test Support Compound and the Area 6 Decontamination Pad and Laundry air sampling programs are summarized in this report. Evaluations are based on Analytical Services Department (ASD) Counting Laboratory analyses and Health Protection Department (HPD)/Radiological Field Operations Section (RFOS) radiation protection technician's (RPT) or health physicists' calculations for air samples collected July 1 through December 31, 1991. Of the NTS operational air sampling programs in the tunnel complexes, the initial mining and event reentry and recovery operations represent the only real airborne radioactive inhalation potentials to personnel. Monthly filter and scintillation cell samples were taken and counted in RDA-200 Radon Detectors to document working levels of radon/thoron daughters and picocurie/liter (PCVL) concentrations of radon gas. Weekly Drierite samples for tritium analysis were taken in the active tunnel complexes to document any changes in normal background levels or reentry drifts as they are advanced toward ground zero (GZ) areas. Underground water sources are considered primary transporters of tritium from old event areas.

  5. Operational air sampling report, July--December 1991

    SciTech Connect

    Lyons, C.L.

    1992-11-01

    Air sampling is one of the more useful ways of assessing the effectiveness of operational radiation safety programs at the Nevada Test Site (NTS). Air sampling programs document NTS airborne radionuclide concentrations in various work locations and environments. These concentrations generally remain well below the Derived Air Concentration (DAC) values prescribed by the Department of Energy (DOE 5480.11, Attachment 1) or the Derived Concentration Guide (DCG) values prescribed by the Department of Energy DOE 5400.5, Chapter Ill. The Defense Nuclear Agency (DNA) tunnel complexes, Area 12 Test Support Compound and the Area 6 Decontamination Pad and Laundry air sampling programs are summarized in this report. Evaluations are based on Analytical Services Department (ASD) Counting Laboratory analyses and Health Protection Department (HPD)/Radiological Field Operations Section (RFOS) radiation protection technician`s (RPT) or health physicists` calculations for air samples collected July 1 through December 31, 1991. Of the NTS operational air sampling programs in the tunnel complexes, the initial mining and event reentry and recovery operations represent the only real airborne radioactive inhalation potentials to personnel. Monthly filter and scintillation cell samples were taken and counted in RDA-200 Radon Detectors to document working levels of radon/thoron daughters and picocurie/liter (PCVL) concentrations of radon gas. Weekly Drierite samples for tritium analysis were taken in the active tunnel complexes to document any changes in normal background levels or reentry drifts as they are advanced toward ground zero (GZ) areas. Underground water sources are considered primary transporters of tritium from old event areas.

  6. SAMPLING AND ANALYSIS PROTOCOLS

    SciTech Connect

    Jannik, T; P Fledderman, P

    2007-02-09

    Radiological sampling and analyses are performed to collect data for a variety of specific reasons covering a wide range of projects. These activities include: Effluent monitoring; Environmental surveillance; Emergency response; Routine ambient monitoring; Background assessments; Nuclear license termination; Remediation; Deactivation and decommissioning (D&D); and Waste management. In this chapter, effluent monitoring and environmental surveillance programs at nuclear operating facilities and radiological sampling and analysis plans for remediation and D&D activities will be discussed.

  7. Diagnosing AIRS Sampling with CloudSat Cloud Classes

    NASA Technical Reports Server (NTRS)

    Fetzer, Eric; Yue, Qing; Guillaume, Alexandre; Kahn, Brian

    2011-01-01

    AIRS yield and sampling vary with cloud state. Careful utilization of collocated multiple satellite sensors is necessary. Profile differences between AIRS and ECMWF model analyses indicate that AIRS has high sampling and excellent accuracy for certain meteorological conditions. Cloud-dependent sampling biases may have large impact on AIRS L2 and L3 data in climate research. MBL clouds / lower tropospheric stability relationship is one example. AIRS and CloudSat reveal a reasonable climatology in the MBL cloud regime despite limited sampling in stratocumulus. Thermodynamic parameters such as EIS derived from AIRS data map these cloud conditions successfully. We are working on characterizing AIRS scenes with mixed cloud types.

  8. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF AIR SAMPLES FOR GC/MS ANALYSIS OF PESTICIDE AND PAH (BCO-L-27.0)

    EPA Science Inventory

    The purpose of this SOP is to describe methods for extracting and preparing an air sample consisting of a quartz fiber filter (Pallflex) and an XAD-2 cartridge for analysis of pesticides and polyaromatic hydrocarbons (PAHs). It covers the preparation of samples that are to be an...

  9. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF AIR SAMPLES FOR GC/MS ANALYSIS OF PESTICIDES AND PAH (BCO-L-27.0)

    EPA Science Inventory

    The purpose of this SOP is to describe methods for extracting and preparing an air sample consisting of a quartz fiber filter (Pallflex) and an XAD-2 cartridge for analysis of pesticides and polynuclear aromatic hydrocarbons (PAHs). It covers the preparation of samples that are ...

  10. Lunar sample analysis

    NASA Technical Reports Server (NTRS)

    Housley, R. M.

    1986-01-01

    A wide variety of lunar sample and meteorite studies were performed. Abstracts of the most recent reports are also attached. Experimental techniques employed have included scanning electron microscopy, transmission electron microscopy, Mossbauer spectroscopy, atomic absorption analysis and a variety of simulation studies.

  11. [Environmental investigation of ground water contamination at Wright-Patterson Air Force Base, Ohio]. Volume 3, Sampling and analysis plan (SAP): Phase 1, Task 4, Field Investigation: Draft

    SciTech Connect

    Not Available

    1991-10-01

    In April 1990, Wright-Patterson Air Force Base (WPAFB), initiated an investigation to evaluate a potential Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) removal action to prevent, to the extent practicable, the offsite migration of contaminated ground water from WPAFB. WPAFB retained the services of the Environmental Management Operations (EMO) and its principle subcontractor, International Technology Corporation (IT) to complete Phase 1 of the environmental investigation of ground-water contamination at WPAFB. Phase 1 of the investigation involves the short-term evaluation and potential design for a program to remove ground-water contamination that appears to be migrating across the western boundary of Area C, and across the northern boundary of Area B along Springfield Pike. Primarily, Task 4 of Phase 1 focuses on collection of information at the Area C and Springfield Pike boundaries of WPAFB. This Sampling and Analysis Plan (SAP) has been prepared to assist in completion of the Task 4 field investigation and is comprised of the Quality Assurance Project Plan (QAPP) and the Field Sampling Plan (FSP).

  12. 40 CFR 1065.1111 - Sample analysis.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Sample analysis. 1065.1111 Section 1065.1111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS... § 1065.1111 Sample analysis. This subpart does not specify chromatographic or analytical methods...

  13. Germanium-76 Sample Analysis

    SciTech Connect

    Kouzes, Richard T.; Engelhard, Mark H.; Zhu, Zihua

    2011-04-01

    The MAJORANA DEMONSTRATOR is a large array of ultra-low background high-purity germanium detectors, enriched in 76Ge, designed to search for zero-neutrino double-beta decay (0νββ). The DEMONSTRATOR will utilize 76Ge from Russia, and the first one gram sample was received from the supplier for analysis on April 24, 2011. The Environmental Molecular Sciences facility, a DOE user facility at PNNL, was used to make the required isotopic and chemical purity measurements that are essential to the quality assurance for the MAJORANA DEMONSTRATOR. The results of this first analysis are reported here.

  14. SAMPLING FOR ORGANIC CHEMICALS IN AIR

    EPA Science Inventory

    Organic chemicals by far account for the majority of pollutants found in air. ore than 90% of the 75,000 chemicals listed in EPA's Toxic Substances Control Act Chemical Substance Inventory and 88% of the 189 Hazardous Air Pollutants (HAPS) named in the Clean Air Act Amendments of...

  15. NID Copper Sample Analysis

    SciTech Connect

    Kouzes, Richard T.; Zhu, Zihua

    2011-09-12

    The current focal point of the nuclear physics program at PNNL is the MAJORANA DEMONSTRATOR, and the follow-on Tonne-Scale experiment, a large array of ultra-low background high-purity germanium detectors, enriched in 76Ge, designed to search for zero-neutrino double-beta decay (0νββ). This experiment requires the use of germanium isotopically enriched in 76Ge. The MAJORANA DEMONSTRATOR is a DOE and NSF funded project with a major science impact. The DEMONSTRATOR will utilize 76Ge from Russia, but for the Tonne-Scale experiment it is hoped that an alternate technology, possibly one under development at Nonlinear Ion Dynamics (NID), will be a viable, US-based, lower-cost source of separated material. Samples of separated material from NID require analysis to determine the isotopic distribution and impurities. DOE is funding NID through an SBIR grant for development of their separation technology for application to the Tonne-Scale experiment. The Environmental Molecular Sciences facility (EMSL), a DOE user facility at PNNL, has the required mass spectroscopy instruments for making isotopic measurements that are essential to the quality assurance for the MAJORANA DEMONSTRATOR and for the development of the future separation technology required for the Tonne-Scale experiment. A sample of isotopically separated copper was provided by NID to PNNL in January 2011 for isotopic analysis as a test of the NID technology. The results of that analysis are reported here. A second sample of isotopically separated copper was provided by NID to PNNL in August 2011 for isotopic analysis as a test of the NID technology. The results of that analysis are also reported here.

  16. Large scale air monitoring: lichen vs. air particulate matter analysis.

    PubMed

    Rossbach, M; Jayasekera, R; Kniewald, G; Thang, N H

    1999-07-15

    Biological indicator organisms have been widely used for monitoring and banking purposes for many years. Although the complexity of the interactions between organisms and their environment is generally not easily comprehensible, environmental quality assessment using the bioindicator approach offers some convincing advantages compared to direct analysis of soil, water, or air. Measurement of air particulates is restricted to experienced laboratories with access to expensive sampling equipment. Additionally, the amount of material collected generally is just enough for one determination per sampling and no multidimensional characterization might be possible. Further, fluctuations in air masses have a pronounced effect on the results from air filter sampling. Combining the integrating property of bioindicators with the world wide availability and particular matrix characteristics of air particulate matter as a prerequisite for global monitoring of air pollution is discussed. A new approach for sampling urban dust using large volume filtering devices installed in air conditioners of large hotel buildings is assessed. A first experiment was initiated to collect air particulates (300-500 g each) from a number of hotels during a period of 3-4 months by successive vacuum cleaning of used inlet filters from high volume air conditioning installations reflecting average concentrations per 3 months in different large cities. This approach is expected to be upgraded and applied for global monitoring. Highly positive correlated elements were found in lichens such as K/S, Zn/P, the rare earth elements (REE) and a significant negative correlation between Hg and Cu was observed in these samples. The ratio of concentrations of elements in dust and Usnea spp. is highest for Cz, Zn and Fe (400-200) and lowest for elements such as Ca, Rb, and Sr (20-10). PMID:10474261

  17. NID Copper Sample Analysis

    SciTech Connect

    Kouzes, Richard T.; Zhu, Zihua

    2011-02-01

    The current focal point of the nuclear physics program at PNNL is the MAJORANA DEMONSTRATOR, and the follow-on Tonne-Scale experiment, a large array of ultra-low background high-purity germanium detectors, enriched in 76Ge, designed to search for zero-neutrino double-beta decay (0νββ). This experiment requires the use of germanium isotopically enriched in 76Ge. The DEMONSTRATOR will utilize 76Ge from Russia, but for the Tonne-Scale experiment it is hoped that an alternate technology under development at Nonlinear Ion Dynamics (NID) will be a viable, US-based, lower-cost source of separated material. Samples of separated material from NID require analysis to determine the isotopic distribution and impurities. The MAJORANA DEMONSTRATOR is a DOE and NSF funded project with a major science impact. DOE is funding NID through an SBIR grant for development of their separation technology for application to the Tonne-Scale experiment. The Environmental Molecular Sciences facility (EMSL), a DOE user facility at PNNL, has the required mass spectroscopy instruments for making these isotopic measurements that are essential to the quality assurance for the MAJORANA DEMONSTRATOR and for the development of the future separation technology required for the Tonne-Scale experiment. A sample of isotopically separated copper was provided by NID to PNNL for isotopic analysis as a test of the NID technology. The results of that analysis are reported here.

  18. Sample Analysis At Mars

    NASA Technical Reports Server (NTRS)

    Brinckerhoff, W. B.; Mahaffy, P. R.; Cabane, M.; Atreya, S. K.; Coll, P.; Cornish, T. J.; Harpold, D. N.; Israel, G.; Niemann, H. B.; Owen, T.

    2003-01-01

    The next landed missions to Mars, such as the planned Mars Science Laboratory and ExoMars, will require sample analysis capabilities refined well beyond what has been flown to date. A key science objective driving this requirement is the determination of the carbon inventory of Mars, and particularly the detection of organic compounds. While the gas chromatograph mass spectrometers (GCMS) on the Viking landers did not detect any indigenous organics in near surface fines, it is possible that these measurements were not representative of Mars on the whole. That is, those compounds to which the GC/MS was sensitive would likely not have survived the strong oxidative decomposition in the regolith at the landing sites in question. The near surface fines could very well contain a significant quantity of refractory compounds that would not have been volatilized in the sample ovens on Viking. It is also possible that volatile organics exist on Mars in sedimentary, subsurface, or polar niches.

  19. Sample Analysis at Mars

    NASA Technical Reports Server (NTRS)

    Brinckerhoff, W. B.; Mahaffy, P. R.; Cabane, M.; Atreya, S. K.; Coll, P.; Cornish, T. J.; Harpold, D. N.; Israel, G.; Niemann, H. B.; Owen, T.

    2003-01-01

    The next landed missions to Mars, such as the planned Mars Science Laboratory and ExoMars, will require sample analysis capabilities refined well beyond what has been flown to date. A key science objective driving this requirement is the determination of the carbon inventory of Mars, and particularly the detection of organic compounds. While the gas chromatograph mass spectrometers (GC/MS) on the Viking landers did not detect any indigenous organics in near surface fines, it is possible that these measurements were not representative of Mars on the whole. That is, those compounds to which the GC/MS was sensitive would likely not have survived the strong oxidative decomposition in the regolith at the landing sites in question. The near surface fines could very well contain a significant quantity of refractory compounds that would not have been volatilized in the sample ovens on Viking. It is also possible that volatile organics exist on Mars in sedimentary, subsurface, or polar niches.

  20. Challenges associated with the sampling and analysis of organosulfur compounds in air using real-time PTR-ToF-MS and offline GC-FID

    NASA Astrophysics Data System (ADS)

    Perraud, Véronique; Meinardi, Simone; Blake, Donald R.; Finlayson-Pitts, Barbara J.

    2016-03-01

    Organosulfur compounds (OSCs) are naturally emitted via various processes involving phytoplankton and algae in marine regions, from animal metabolism, and from biomass decomposition inland. These compounds are malodorant and reactive. Their oxidation to methanesulfonic and sulfuric acids leads to the formation and growth of atmospheric particles, which are known to influence clouds and climate, atmospheric chemical processes. In addition, particles in air have been linked to negative impacts on visibility and human health. Accurate measurements of the OSC precursors are thus essential to reduce uncertainties in their sources and contributions to particle formation in air. Two different approaches, proton-transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) and canister sampling coupled to gas chromatography with flame ionization detector (GC-FID), are compared for both laboratory standards (dimethyl sulfide, DMS; dimethyl disulfide, DMDS; dimethyl trisulfide, DMTS; and methanethiol, MTO) and for a complex sample. Results show that both techniques produce accurate quantification of DMS. While PTR-ToF-MS provides real-time measurements of all four OSCs individually, significant fragmentation of DMDS and DMTS occurs, which can complicate their identification in complex mixtures. Canister sampling coupled with GC-FID provides excellent sensitivity for DMS, DMDS, and DMTS. However, MTO was observed to react on metal surfaces to produce DMDS and, in the presence of hydrogen sulfide, even DMTS. Avoiding metal in sampling systems seems to be necessary for measuring all but dimethyl sulfide in air.

  1. Evaluation of membrane filter field monitors for microbiological air sampling

    NASA Technical Reports Server (NTRS)

    Fields, N. D.; Oxborrow, G. S.; Puleo, J. R.; Herring, C. M.

    1974-01-01

    Due to area constraints encountered in assembly and testing areas of spacecraft, the membrane filter field monitor (MF) and the National Aeronautics and Space Administration-accepted Reyniers slit air sampler were compared for recovery of airborne microbial contamination. The intramural air in a microbiological laboratory area and a clean room environment used for the assembly and testing of the Apollo spacecraft was studied. A significantly higher number of microorganisms was recovered by the Reyniers sampler. A high degree of consistency between the two sampling methods was shown by a regression analysis, with a correlation coefficient of 0.93. The MF samplers detected 79% of the concentration measured by the Reyniers slit samplers. The types of microorganisms identified from both sampling methods were similar.

  2. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF METALS FROM SOIL, DUST, AIR FILTER, AND SURFACE AND DERMAL SAMPLES FOR AA (GRAPHITE FURNACE OR FLAME) OR ICP-AES ANALYSIS (BCO-L-3.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the acid digestion of soil, house dust, air filter, and surface or dermal wipe samples for analysis using inductively coupled plasma atomic emissions spectrometry (ICP-AES) and/or graphite furnace atomic absorption spectrometry (GFAAS) or fl...

  3. Revisiting sample entropy analysis

    NASA Astrophysics Data System (ADS)

    Govindan, R. B.; Wilson, J. D.; Eswaran, H.; Lowery, C. L.; Preißl, H.

    2007-03-01

    We modify the definition of sample entropy (SaEn) by incorporating a time delay between the components of the block (from which the densities are estimated) and show that the modified method characterizes the complexity of the system better than the original version. We apply the modified SaEn to the standard deterministic systems and stochastic processes (uncorrelated and long range correlated (LRC) processes) and show that the underlying complexity of the system is better quantified by the modified method. We extend this analysis to the RR intervals of the normal and congestive heart failure (CHF) subjects (available via www.physionet.org) and show that there is a good degree of separation between the two groups.

  4. Optimization of the development process for air sampling filter standards

    NASA Astrophysics Data System (ADS)

    Mena, RaJah Marie

    Air monitoring is an important analysis technique in health physics. However, creating standards which can be used to calibrate detectors used in the analysis of the filters deployed for air monitoring can be challenging. The activity of a standard should be well understood, this includes understanding how the location within the filter affects the final surface emission rate. The purpose of this research is to determine the parameters which most affect uncertainty in an air filter standard and optimize these parameters such that calibrations made with them most accurately reflect the true activity contained inside. A deposition pattern was chosen from literature to provide the best approximation of uniform deposition of material across the filter. Samples sets were created varying the type of radionuclide, amount of activity (high activity at 6.4 -- 306 Bq/filter and one low activity 0.05 -- 6.2 Bq/filter, and filter type. For samples analyzed for gamma or beta contaminants, the standards created with this procedure were deemed sufficient. Additional work is needed to reduce errors to ensure this is a viable procedure especially for alpha contaminants.

  5. Extraction of CO2 from air samples for isotopic analysis and limits to ultra high precision delta18O determination in CO2 gas.

    PubMed

    Werner, R A; Rothe, M; Brand, W A

    2001-01-01

    The determination of delta18O values in CO2 at a precision level of +/-0.02 per thousand (delta-notation) has always been a challenging, if not impossible, analytical task. Here, we demonstrate that beyond the usually assumed major cause of uncertainty - water contamination - there are other, hitherto underestimated sources of contamination and processes which can alter the oxygen isotope composition of CO2. Active surfaces in the preparation line with which CO2 comes into contact, as well as traces of air in the sample, can alter the apparent delta18O value both temporarily and permanently. We investigated the effects of different surface materials including electropolished stainless steel, Duran glass, gold and quartz, the latter both untreated and silanized. CO2 frozen with liquid nitrogen showed a transient alteration of the 18O/16O ratio on all surfaces tested. The time to recover from the alteration as well as the size of the alteration varied with surface type. Quartz that had been ultrasonically cleaned for several hours with high purity water (0.05 microS) exhibited the smallest effect on the measured oxygen isotopic composition of CO2 before and after freezing. However, quartz proved to be mechanically unstable with time when subjected to repeated large temperature changes during operation. After several days of operation the gas released from the freezing step contained progressively increasing trace amounts of O2 probably originating from inclusions within the quartz, which precludes the use of quartz for cryogenically trapping CO2. Stainless steel or gold proved to be suitable materials after proper pre-treatment. To ensure a high trapping efficiency of CO2 from a flow of gas, a cold trap design was chosen comprising a thin wall 1/4" outer tube and a 1/8" inner tube, made respectively from electropolished stainless steel and gold. Due to a considerable 18O specific isotope effect during the release of CO2 from the cold surface, the thawing time had to

  6. A continuous sampling air-ICP for metals emission monitoring

    SciTech Connect

    Baldwin, D.P.; Zamzow, D.S.; Eckels, D.E.; Miller, G.P.

    1999-09-19

    An air-inductively coupled plasma (air-ICP) system has been developed for continuous sampling and monitoring of metals as a continuous emission monitor (CEM). The plasma is contained in a metal enclosure to allow reduced-pressure operation. The enclosure and plasma are operated at a pressure slightly less than atmospheric using a Roots blower, so that sample gas is continuously drawn into the plasma. A Teflon sampling chamber, equipped with a sampling pump, is connected to the stack that is to be monitored to isokinetically sample gas from the exhaust line and introduce the sample into the air-ICP. Optical emission from metals in the sampled gas stream is detected and monitored using an acousto-optic tunable filter (AOTF)--echelle spectrometer system. A description of the continuous sampling air-ICP system is given, along with some preliminary laboratory data for continuous monitoring of metals.

  7. Continuous sampling air-ICP for metals emission monitoring

    NASA Astrophysics Data System (ADS)

    Baldwin, David P.; Zamzow, Daniel S.; Eckels, David E.; Miller, George P.

    1999-12-01

    An air-inductively coupled plasma (air-ICP) system has been developed for continuous sampling and monitoring of metals as a continuous emission monitor (CEM). The plasma is contained in a metal enclosure to allow reduced-pressure operation. The enclosure and plasma are operated at a pressure slightly less than atmospheric using a Roots blower, so that sample gas is continuously drawn into the plasma. A Teflon sampling chamber, equipped with a sampling pump, is connected to the stack that is to be monitored to isokinetically sample gas from the exhaust line and introduce the sample into the air-ICP. Optical emission from metals in the sampled gas stream is detected and monitored using an acousto-optic tunable filter (AOTF)-echelle spectrometer system. A description of the continuous sampling air-ICP system is given, along with some preliminary laboratory data for continuous monitoring of metals.

  8. Carbonaceous species methods comparison study at Citrus College. Task: analysis for trace hydrocarbons and related halocarbons in urban ambient air samples. Final report

    SciTech Connect

    Rasmussen, R.A.

    1987-10-01

    As part of the ARB-sponsored Carbonaceous Species Methods Comparison Study (CSMCS) in Glendora, CA, from August 11-21, 1986, time-integrated, ambient samples were collected in stainless steel canisters. Five samples per day were collected, ranging from 4 to 8 hours according to the CSMCS protocol. The species measured included CO, CH/sub 4/, CO/sub 2/, H/sub 2/, and the C/sub 2/ through C10 hydrocarbons. In addition, N/sub 2/O, the halocarbons F-12, F-11, F-113, CHCl/sub 3/, CH/sub 3/CCl/sub 3/, CCl/sub 4/, C/sub 2/HCl/sub 3/ and C/sub 2/Cl/sub 4/ were measured. Four gas-chromatograph systems were used to quantify these species. The report contains tables of concentrations of the species measured at the South Coast Air Basin site during smoggy summer conditions.

  9. Venturi Air-Jet Vacuum Ejector For Sampling Air

    NASA Technical Reports Server (NTRS)

    Hill, Gerald F.; Sachse, Glen W.; Burney, L. Garland; Wade, Larry O.

    1990-01-01

    Venturi air-jet vacuum ejector pump light in weight, requires no electrical power, does not contribute heat to aircraft, and provides high pumping speeds at moderate suctions. High-pressure motive gas required for this type of pump bled from compressor of aircraft engine with negligible effect on performance of engine. Used as source of vacuum for differential-absorption CO-measurement (DACOM), modified to achieve in situ measurements of CO at frequency response of 10 Hz. Provides improvement in spatial resolution and potentially leads to capability to measure turbulent flux of CO by use of eddy-correlation technique.

  10. Corn leaf nitrate reductase - A nontoxic alternative to cadmium for photometric nitrate determinations in water samples by air-segmented continuous-flow analysis

    USGS Publications Warehouse

    Patton, C.J.; Fischer, A.E.; Campbell, W.H.; Campbell, E.R.

    2002-01-01

    Development, characterization, and operational details of an enzymatic, air-segmented continuous-flow analytical method for colorimetric determination of nitrate + nitrite in natural-water samples is described. This method is similar to U.S. Environmental Protection Agency method 353.2 and U.S. Geological Survey method 1-2545-90 except that nitrate is reduced to nitrite by soluble nitrate reductase (NaR, EC 1.6.6.1) purified from corn leaves rather than a packed-bed cadmium reactor. A three-channel, air-segmented continuous-flow analyzer-configured for simultaneous determination of nitrite (0.020-1.000 mg-N/L) and nitrate + nitrite (0.05-5.00 mg-N/L) by the nitrate reductase and cadmium reduction methods-was used to characterize analytical performance of the enzymatic reduction method. At a sampling rate of 90 h-1, sample interaction was less than 1% for all three methods. Method detection limits were 0.001 mg of NO2- -N/L for nitrite, 0.003 mg of NO3-+ NO2- -N/L for nitrate + nitrite by the cadmium-reduction method, and 0.006 mg of NO3- + NO2- -N/L for nitrate + nitrite by the enzymatic-reduction method. Reduction of nitrate to nitrite by both methods was greater than 95% complete over the entire calibration range. The difference between the means of nitrate + nitrite concentrations in 124 natural-water samples determined simultaneously by the two methods was not significantly different from zero at the p = 0.05 level.

  11. Challenges associated with the sampling and analysis of organosulfur compounds in air using real-time PTR-ToF-MS and off-line GC-FID

    NASA Astrophysics Data System (ADS)

    Perraud, V.; Meinardi, S.; Blake, D. R.; Finlayson-Pitts, B. J.

    2015-12-01

    Organosulfur compounds (OSC) are naturally emitted via various processes involving phytoplankton and algae in marine regions, from animal metabolism and from biomass decomposition inland. These compounds are malodorant and reactive. Their oxidation to methanesulfonic and sulfuric acids leads to the formation and growth of atmospheric particles, which are known to have negative effects on visibility, climate and human health. In order to predict particle formation events, accurate measurements of the OSC precursors are essential. Here, two different approaches, proton-transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) and canister sampling coupled with GC-FID are compared for both laboratory standards [dimethyl sulfide (DMS), dimethyl disulfide (DMDS), dimethyl trisulfide (DMTS) and methanethiol (MTO)] and for a complex sample. Results show that both techniques produce accurate quantification of DMS. While PTR-ToF-MS provides real-time measurements of all four OSCs individually, significant fragmentation of DMDS and DMTS occurs, which can complicate their identification in complex mixtures. Canister sampling coupled with GC-FID provides excellent sensitivity for DMS, DMDS and DMTS. However, MTO was observed to react on metal surfaces to produce DMDS and, in the presence of hydrogen sulfide, even DMTS. Avoiding metal in sampling systems seems to be necessary for measuring all but dimethyl sulfide in air.

  12. Does Traffic-related Air Pollution Explain Associations of Aircraft and Road Traffic Noise Exposure on Children's Health and Cognition? A Secondary Analysis of the United Kingdom Sample From the RANCH Project

    PubMed Central

    Clark, Charlotte; Crombie, Rosanna; Head, Jenny; van Kamp, Irene; van Kempen, Elise; Stansfeld, Stephen A.

    2012-01-01

    The authors examined whether air pollution at school (nitrogen dioxide) is associated with poorer child cognition and health and whether adjustment for air pollution explains or moderates previously observed associations between aircraft and road traffic noise at school and children's cognition in the 2001–2003 Road Traffic and Aircraft Noise Exposure and Children's Cognition and Health (RANCH) project. This secondary analysis of a subsample of the United Kingdom RANCH sample examined 719 children who were 9–10 years of age from 22 schools around London's Heathrow airport for whom air pollution data were available. Data were analyzed using multilevel modeling. Air pollution exposure levels at school were moderate, were not associated with a range of cognitive and health outcomes, and did not account for or moderate associations between noise exposure and cognition. Aircraft noise exposure at school was significantly associated with poorer recognition memory and conceptual recall memory after adjustment for nitrogen dioxide levels. Aircraft noise exposure was also associated with poorer reading comprehension and information recall memory after adjustment for nitrogen dioxide levels. Road traffic noise was not associated with cognition or health before or after adjustment for air pollution. Moderate levels of air pollution do not appear to confound associations of noise on cognition and health, but further studies of higher air pollution levels are needed. PMID:22842719

  13. Does traffic-related air pollution explain associations of aircraft and road traffic noise exposure on children's health and cognition? A secondary analysis of the United Kingdom sample from the RANCH project.

    PubMed

    Clark, Charlotte; Crombie, Rosanna; Head, Jenny; van Kamp, Irene; van Kempen, Elise; Stansfeld, Stephen A

    2012-08-15

    The authors examined whether air pollution at school (nitrogen dioxide) is associated with poorer child cognition and health and whether adjustment for air pollution explains or moderates previously observed associations between aircraft and road traffic noise at school and children's cognition in the 2001-2003 Road Traffic and Aircraft Noise Exposure and Children's Cognition and Health (RANCH) project. This secondary analysis of a subsample of the United Kingdom RANCH sample examined 719 children who were 9-10 years of age from 22 schools around London's Heathrow airport for whom air pollution data were available. Data were analyzed using multilevel modeling. Air pollution exposure levels at school were moderate, were not associated with a range of cognitive and health outcomes, and did not account for or moderate associations between noise exposure and cognition. Aircraft noise exposure at school was significantly associated with poorer recognition memory and conceptual recall memory after adjustment for nitrogen dioxide levels. Aircraft noise exposure was also associated with poorer reading comprehension and information recall memory after adjustment for nitrogen dioxide levels. Road traffic noise was not associated with cognition or health before or after adjustment for air pollution. Moderate levels of air pollution do not appear to confound associations of noise on cognition and health, but further studies of higher air pollution levels are needed. PMID:22842719

  14. PBDEs in environmental samples: sampling and analysis.

    PubMed

    Król, Sylwia; Zabiegała, Bożena; Namieśnik, Jacek

    2012-05-15

    The paper reviews the subject literature concerning analytical procedures routinely sed for monitoring polybrominated diphenyl ethers (PBDE) in environmental samples. It describes and summarizes subsequent stages of analytical procedure including sample collection and preparation, extraction, clean-up and final determination. Different approaches with their advantages and limitations are presented. Special attention is drawn to the newly developed, promising extraction techniques, especially: liquid-liquid-microextraction (LLME) with its modifications, cloud point extraction (CPE) and hollow fiber microextraction. The review compares available detection techniques taking into account their usefulness for determining different PBDEs in complex matrix as well as discussing possible limitations that may occur during the analysis. The quality assurance and quality control aspect of analytical procedure is described. Finally special attention is paid to the determination of highly brominated PBDE compounds (e.g. BDE209), which requires implementation of different analytical approach. PMID:22483870

  15. Ozone measurement system for NASA global air sampling program

    NASA Technical Reports Server (NTRS)

    Tiefermann, M. W.

    1979-01-01

    The ozone measurement system used in the NASA Global Air Sampling Program is described. The system uses a commercially available ozone concentration monitor that was modified and repackaged so as to operate unattended in an aircraft environment. The modifications required for aircraft use are described along with the calibration techniques, the measurement of ozone loss in the sample lines, and the operating procedures that were developed for use in the program. Based on calibrations with JPL's 5-meter ultraviolet photometer, all previously published GASP ozone data are biased high by 9 percent. A system error analysis showed that the total system measurement random error is from 3 to 8 percent of reading (depending on the pump diaphragm material) or 3 ppbv, whichever are greater.

  16. 24-HOUR DIFFUSIVE SAMPLING OF 1,3-BUTADIENE IN AIR ONTO CARBOPACK X SOLID ADSORBENT FOLLOWED BY THERMAL DESORPTION/GC/MS ANALYSIS - FEASIBILITY STUDY

    EPA Science Inventory

    Diffusive sampling of 1,3-butadiene for 24 hr onto the graphitic adsorbent Carbopack X packed in a stainless steel tube badge (6.3 mm o.d., 5 mm i.d., and 90 mm in length) with analysis by thermal desorption/gas chromatography (GC)/mass spectrometry (MS) has been evaluated in con...

  17. 24-HOUR DIFFUSIVE SAMPLING OF 1,3-BUTADIENE IN AIR ONTO CARBONPAK X SOLID ADSORBENT WITH THEMAL DESORPTION/GC/MS ANALYSIS - FEASIBILITY STUDIES

    EPA Science Inventory

    Diffusive sampling of 1,3-butadiene for 24 hours onto the graphitic adsorbent Carbopack X contained in a stainless steel tube badge (6.3 mm OD, 5 mm ID, and 90 mm in length) with analysis by thermal desorption/GC/MS has been evaluated in controlled tests. A test matrix of 42 tr...

  18. 13c Measurements On Air of Small Ice Samples

    NASA Astrophysics Data System (ADS)

    Eyer, M.; Leuenberger, M.

    We have developed a new method for 13C analysis for very small air amounts of less than 0.5 cc STP, corresponding to less than 10 gram of ice. It is based on the needle-crasher technique, which we routinely use for CO2 concentration measurements by infrared laser absorption. The extracted air is slowly expanded into a large volume through a water trap held at ­100°C. This sampled air is then carried by a high helium flux through a modified Precon system of Thermo-Finnigan to separate CO2 from the air and to inject the pure CO2 gas in a low helium stream via an open split device to a Delta Plus XL mass spectrometer. The overall precision based on replicates of standard air is significantly better than 0.1 for a single analysis and is further improved by a triplicate measurement of the same sample through a specially designed gas splitter. We have used this new method for investigations on polar ice cores. The 13C measurements are important for climate reconstructions, e.g. to reconstruct the evolution and its variability in the terrestrial and oceanic carbon sinks and to identify natural variations in the marine carbon cycle. During the industrialization atmospheric 13C decreased by about -2, mainly due to the anthropogenic release of biogenic CO2 by fossil fuel burning. Reconstructions of carbon and oxygen cycles of Joos at al. [1999] using a double deconvolution method show that between 1930 and 1950 the net terrestrial release is changing to a net terrestrial uptake of CO2. A highly resolved 13C dataset of this time window would replenish the documentation of this behaviour. Further, it would be interesting to compare such data with O2/N2 measurements, known as an other partitioning tool for carbon sources and sinks. At the EGS 2002 we will present a highly resolved 13C record from Antarctic ice covering this time period.

  19. Sampling for Chemical Analysis.

    ERIC Educational Resources Information Center

    Kratochvil, Byron; And Others

    1984-01-01

    This review, designed to make analysts aware of uncertainties introduced into analytical measurements during sampling, is organized under these headings: general considerations; theory; standards; and applications related to mineralogy, soils, sediments, metallurgy, atmosphere, water, biology, agriculture and food, medical and clinical areas, oil…

  20. Temporal-spatial analysis of U.S.-Mexico border environmental fine and coarse PM air sample extract activity in human bronchial epithelial cells

    SciTech Connect

    Lauer, Fredine T.; Mitchell, Leah A.; Bedrick, Edward; McDonald, Jacob D.; Lee, Wen-Yee; Li, Wen-Whai; Olvera, Hector; Amaya, Maria A.; Berwick, Marianne; Gonzales, Melissa; Currey, Robert; Pingitore, Nicholas E.

    2009-07-01

    Particulate matter less than 10 {mu}m (PM10) has been shown to be associated with aggravation of asthma and respiratory and cardiopulmonary morbidity. There is also great interest in the potential health effects of PM2.5. Particulate matter (PM) varies in composition both spatially and temporally depending on the source, location and seasonal condition. El Paso County which lies in the Paso del Norte airshed is a unique location to study ambient air pollution due to three major points: the geological land formation, the relatively large population and the various sources of PM. In this study, dichotomous filters were collected from various sites in El Paso County every 7 days for a period of 1 year. The sampling sites were both distant and near border crossings, which are near heavily populated areas with high traffic volume. Fine (PM2.5) and Coarse (PM10-2.5) PM filter samples were extracted using dichloromethane and were assessed for biologic activity and polycyclic aromatic (PAH) content. Three sets of marker genes human BEAS2B bronchial epithelial cells were utilized to assess the effects of airborne PAHs on biologic activities associated with specific biological pathways associated with airway diseases. These pathways included in inflammatory cytokine production (IL-6, IL-8), oxidative stress (HMOX-1, NQO-1, ALDH3A1, AKR1C1), and aryl hydrocarbon receptor (AhR)-dependent signaling (CYP1A1). Results demonstrated interesting temporal and spatial patterns of gene induction for all pathways, particularly those associated with oxidative stress, and significant differences in the PAHs detected in the PM10-2.5 and PM2.5 fractions. Temporally, the greatest effects on gene induction were observed in winter months, which appeared to correlate with inversions that are common in the air basin. Spatially, the greatest gene expression increases were seen in extracts collected from the central most areas of El Paso which are also closest to highways and border crossings.

  1. APPLICATION OF SEMIPERMEABLE MEMBRANE DEVICES TO INDOOR AIR SAMPLING

    EPA Science Inventory

    Semipermeable membrane devices (SPMDs) are a relatively new passive sampling technique for nonpolar organic compounds that have been extensively used for surface water sampling. A small body of literature indicates that SPMDs are also useful for air sampling. Because SPMDs ha...

  2. Sampling of nitrates in ambient air

    NASA Astrophysics Data System (ADS)

    Appel, B. R.; Tokiwa, Y.; Haik, M.

    Methods for the measurement of nitric acid, particulate nitrate and total inorganic nitrate (i.e. HNO 3 plus particulate nitrate) are compared using atmospheric samples from the Los Angeles Basin. Nitric acid was measured by (1) the nitrate collected on nylon or NaCl-impregnated cellulose filters after removal of particulate matter with Teflon prefilters, (2) long-path Fourier transform infrared spectroscopy (FTIR) performed by a collaborating investigator, and (3) the difference between total inorganic nitrate (TIN) and particulate nitrate (PN). TIN was measured by the sum of the nitrate collected with a Teflon prefilter and nylon or NaCl-impregnated after-filter. PN was measured by the nitrate able to penetrate a diffusion dénuder coated to remove acidic gases (e.g. HNO 3). Losses of nitrate from Teflon prefilters were determined by comparing the nitrate retained by these filters to the nitrate penetrating the acid gas denuder. TIN and the nitrate collected with glass fiber filters were compared to assess the origin of the artifact particulate nitrate on the latter. Nitric acid measurements using nylon or NaCl-impregnated after-filters were substantially higher than those by the difference technique. This correlated with losses of nitrate from the Teflon prefilters, which exceeded 50 % at high ambient temperature and low relative humidity. Nitric acid by the difference method exceeded that by FTIR by, on average, 20 %. Thus errors inferred in HNO 3 measurements by comparison to the difference measurements are considered minimum values. The high values for HNO 3 by the difference method are consistent with the partial loss of PN in the acid gas denuder. However, no loss of 0.1 μm to 3 μm diameter NH 4NO 3 particles was observed. Thus, if significant, such loss is restricted to coarse particulate nitrate. Heating the filter samplers was shown to increase sampling errors. Nitrate results obtained in short-term, low volume sampling with Gelman A glass fiber

  3. STATISTICAL SAMPLING AND DATA ANALYSIS

    EPA Science Inventory

    Research is being conducted to develop approaches to improve soil and sediment sampling techniques, measurement design and geostatistics, and data analysis via chemometric, environmetric, and robust statistical methods. Improvements in sampling contaminated soil and other hetero...

  4. EML Surface Air Sampling Program, 1990--1993 data

    SciTech Connect

    Larsen, R.J.; Sanderson, C.G.; Kada, J.

    1995-11-01

    Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory`s Surface Air Sampling Program (SASP) during 1990--1993, with the exception of April 1993, indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the sampling and analytical techniques that were used to collect and measure them. The occasional detection of {sup 137}Cs in some air filter samples may have resulted from resuspension of previously deposited debris. Following the April 6, 1993 accident and release of radionuclides into the atmosphere at a reprocessing plant in the Tomsk-7 military nuclear complex located 16 km north of the Siberian city of Tomsk, Russia, weekly air filter samples from Barrow, Alaska; Thule, Greenland and Moosonee, Canada were selected for special analyses. The naturally occurring radioisotopes that the authors measure, {sup 7}Be and {sup 210}Pb, continue to be detected in most air filter samples. Variations in the annual mean concentrations of {sup 7}Be at many of the sites appear to result primarily from changes in the atmospheric production rate of this cosmogenic radionuclide. Short-term variations in the concentrations of {sup 7}Be and {sup 210}Pb continued to be observed at many sites at which weekly air filter samples were analyzed. The monthly gross gamma-ray activity and the monthly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb measured at sampling sites in SASP during 1990--1993 are presented. The weekly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb for samples collected during 1990--1993 are given for 17 sites.

  5. Automated Sample collection and Analysis unit

    SciTech Connect

    Latner, Norman; Sanderson, Colin G.; Negro, Vincent C.

    1999-03-31

    Autoramp is an atmospheric radionuclide collection and analysis unit designed for unattended operation. A large volume of air passes through one of 31 filter cartridges which is then moved from a sampling chamber and past a bar code reader, to a shielded enclosure. The collected dust-borne radionuclides are counted with a high resolution germanium gamma-ray detector. An analysis is made and the results are transmitted to a central station that can also remotely control the unit.

  6. Air Pollution. Part A: Analysis.

    ERIC Educational Resources Information Center

    Ledbetter, Joe O.

    Two facets of the engineering control of air pollution (the analysis of possible problems and the application of effective controls) are covered in this two-volume text. Part A covers Analysis, and Part B, Prevention and Control. (This review is concerned with Part A only.) This volume deals with the terminology, methodology, and symptomatology…

  7. Efficiency of dust sampling inlets in calm air.

    PubMed

    Breslin, J A; Stein, R L

    1975-08-01

    Measurement of airborne dust concentrations usually involves drawing a sample of the dust-laden air into the measuring instrument through an inlet. Even if the surrounding air is calm, theoretical calculations predict that large particles may not be sampled accurately due to the combined effects of gravity and inertia on the particles near the sampling inlet. Tests were conducted to determine the conditions of particle size, inlet radius, and flow rare necessary for accurate dust sampling. A coal-dust aerosol was sampled simultaneously through inlets of different diameters at the same volume flow-rate and collected on filters. The dust was removed from the filters and the particles were counted and sized with a Coulter counter. Results showed that published criteria for inlet conditions for correct sampling are overly restrictive and that respirable-size particles are sampled correctly in the normal range or operation of most dust sampling instruments. PMID:1227283

  8. Rapid on-site air sampling with a needle extraction device for evaluating the indoor air environment in school facilities.

    PubMed

    Inoue, Mitsuru; Mizuguchi, Ayako; Ueta, Ikuo; Takahashi, Kazuya; Saito, Yoshihiro

    2013-01-01

    A rapid on-site air sampling technique was developed with a miniaturized needle-type sample preparation device for a systematic evaluation of the indoor air environments in school facilities. With the in-needle extraction device packed with a polymer particle of divinylbenzene and activated carbon particles, various types of volatile organic compounds (VOCs) were successfully extracted. For evaluating the indoor air qualities in school facilities, air samples in renovated rooms using organic solvent as a thinner of the paint were analyzed along with measurements of several VOCs in indoor air samples taken in newly built primary schools mainly using low-VOCs materials. After periodical renovation/maintenance, the time-variation profile of typical VOCs found in the school facilities has also been monitored. From the results, it could be observed that the VOCs in most of the rooms in these primary schools were at a quite low level; however, a relatively higher concentration of VOCs was found in some specially designed rooms, such as music rooms. In addition, some non-regulated compounds, including benzyl alcohol and branched alkanes, were detected in these primary schools. The results showed a good applicability of the needle device to indoor air analysis in schools, suggesting a wide range of future employment of the needle device, especially for indoor air analysis in other types of facilities and rooms including hospitals and hotels. PMID:23665624

  9. Summary of gamma spectrometry on local air samples from 1985--1995

    SciTech Connect

    Winn, W.G.

    1997-04-02

    This report summarizes the 1985--1995 results of low-level HPGe gamma spectrometry analysis of high-volume air samples collected at the Aiken Airport, which is about 25 miles north of SRS. The author began analyzing these samples with new calibrations using the newly developed GRABGAM code in 1985. The air sample collections were terminated in 1995, as the facilities at the Aiken Airport were no longer available. Air sample measurements prior to 1985 were conducted with a different analysis system (and by others prior to 1984), and the data were not readily available. The report serves to closeout this phase of local NTS air sample studies, while documenting the capabilities and accomplishments. Hopefully, the information will guide other applications for this technology, both locally and elsewhere.

  10. Innovations in air sampling to detect plant pathogens

    PubMed Central

    West, JS; Kimber, RBE

    2015-01-01

    Many innovations in the development and use of air sampling devices have occurred in plant pathology since the first description of the Hirst spore trap. These include improvements in capture efficiency at relatively high air-volume collection rates, methods to enhance the ease of sample processing with downstream diagnostic methods and even full automation of sampling, diagnosis and wireless reporting of results. Other innovations have been to mount air samplers on mobile platforms such as UAVs and ground vehicles to allow sampling at different altitudes and locations in a short space of time to identify potential sources and population structure. Geographical Information Systems and the application to a network of samplers can allow a greater prediction of airborne inoculum and dispersal dynamics. This field of technology is now developing quickly as novel diagnostic methods allow increasingly rapid and accurate quantifications of airborne species and genetic traits. Sampling and interpretation of results, particularly action-thresholds, is improved by understanding components of air dispersal and dilution processes and can add greater precision in the application of crop protection products as part of integrated pest and disease management decisions. The applications of air samplers are likely to increase, with much greater adoption by growers or industry support workers to aid in crop protection decisions. The same devices are likely to improve information available for detection of allergens causing hay fever and asthma or provide valuable metadata for regional plant disease dynamics. PMID:25745191

  11. EVALUATION OF HIGH VOLUME PARTICLE SAMPLING AND SAMPLE HANDLING PROTOCOLS FOR AMBIENT URBAN AIR MUTAGENICITY DETERMINATIONS

    EPA Science Inventory

    An investigation of high volume particle sampling and sample handling procedures was undertaken to evaluate variations of protocols being used by the U.S Environmental Protection Agency. hese protocols are used in urban ambient air studies which collect ambient and source samples...

  12. Air Monitoring: New Advances in Sampling and Detection

    PubMed Central

    Watson, Nicola; Davies, Stephen; Wevill, David

    2011-01-01

    As the harmful effects of low-level exposure to hazardous organic air pollutants become more evident, there is constant pressure to improve the detection limits of indoor and ambient air monitoring methods, for example, by collecting larger air volumes and by optimising the sensitivity of the analytical detector. However, at the other end of the scale, rapid industrialisation in the developing world and growing pressure to reclaim derelict industrial land for house building is driving the need for air monitoring methods that can reliably accommodate very-high-concentration samples in potentially aggressive matrices. This paper investigates the potential of a combination of two powerful gas chromatography—based analytical enhancements—sample preconcentration/thermal desorption and time-of-flight mass spectrometry—to improve quantitative and qualitative measurement of very-low-(ppt) level organic chemicals, even in the most complex air samples. It also describes new, practical monitoring options for addressing equally challenging high-concentration industrial samples. PMID:22241966

  13. Evaluation of the effect of different sampling time periods and ambient air pollutant concentrations on the performance of the Radiello diffusive sampler for the analysis of VOCs by TD-GC/MS.

    PubMed

    Gallego, E; Roca, F J; Perales, J F; Guardino, X

    2011-09-01

    The effect of different sampling exposure times and ambient air pollutant concentrations on the performance of Radiello® samplers for analysis of volatile organic compounds (VOCs) is evaluated. Quadruplicate samples of Radiello® passive tubes were taken for 3, 4, 7 and 14 days. Samples were taken indoors during February and March 2010 and outdoors during July 2010 in La Canonja (Tarragona, Spain). The analysis was performed by automatic thermal desorption (ATD) coupled with capillary gas chromatography (GC)/mass spectrometry detection (MS). The results show significant differences (t-test, p < 0.05) between the amounts of VOCs obtained from the sum of two short sampling periods and a single equivalent longer sampling period for 65% of all the data. 17% of the results show significantly larger amounts of pollutant in the sum of two short sampling periods. Back diffusion due to changes in concentrations together with saturation and competitive effects between the compounds during longer sampling periods could be responsible for these differences. The other 48% of the results that are different show significantly larger amounts in the single equivalent longer sampling period. The remaining 35% of the results do not show significant differences. Although significant differences are observed in the amount of several VOCs collected over two shorter sampling intervals compared to the amount collected during a single equivalent longer sampling period, the ratios obtained are very close to unity (between 0.7 and 1.2 in 75% of cases). We conclude that Radiello® passive samplers are useful tools if their limitations are taken into account and the manufacturer's recommendations are followed. PMID:21829856

  14. DUS II SOIL GAS SAMPLING AND AIR INJECTION TEST RESULTS

    SciTech Connect

    Noonkester, J.; Jackson, D.; Jones, W.; Hyde, W.; Kohn, J.; Walker, R.

    2012-09-20

    Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected

  15. Microorganisms cultured from stratospheric air samples obtained at 41 km.

    PubMed

    Wainwright, M; Wickramasinghe, N C; Narlikar, J V; Rajaratnam, P

    2003-01-21

    Samples of air removed from the stratosphere, at an altitude of 41 km, were previously found to contain viable, but non-cultureable bacteria (cocci and rods). Here, we describe experiments aimed at growing these, together with any other organisms, present in these samples. Two bacteria (Bacillus simplex and Staphylococcus pasteuri) and a single fungus, Engyodontium album (Limber) de Hoog were isolated from the samples. Although the possibility of contamination can never be ruled out when space-derived samples are studied on earth, we are confident that the organisms originated from the stratosphere. Possible mechanisms by which these organisms could have attained such a height are discussed. PMID:12583913

  16. Sampling frequency guidance for ambient air toxics monitoring.

    PubMed

    Bortnick, Steven M; Stetzer, Shannon L

    2002-07-01

    The U.S. Environmental Protection Agency (EPA) is in the process of designing a national network to monitor hazardous air pollutants (HAPs), also known as air toxics. The purposes of the expanded monitoring are to (1) characterize ambient concentrations in representative areas; (2) provide data to support and evaluate dispersion and receptor models; and (3) establish trends and evaluate the effectiveness of HAP emission reduction strategies. Existing air toxics data, in the form of an archive compiled by EPA's Office of Air Quality Planning and Standards (OAQPS), are used in this paper to examine the relationship between estimated annual average (AA) HAP concentrations and their associated variability. The goal is to assess the accuracy, or bias and precision, with which the AA can be estimated as a function of ambient concentration levels and sampling frequency. The results suggest that, for several air toxics, a sampling schedule of 1 in 3 days (1:3) or 1:6 days maybe appropriate for meeting some of the general objectives of the national network, with the more intense sampling rate being recommended for areas expected to exhibit relatively high ambient levels. PMID:12139351

  17. A method to optimize sampling locations for measuring indoor air distributions

    NASA Astrophysics Data System (ADS)

    Huang, Yan; Shen, Xiong; Li, Jianmin; Li, Bingye; Duan, Ran; Lin, Chao-Hsin; Liu, Junjie; Chen, Qingyan

    2015-02-01

    Indoor air distributions, such as the distributions of air temperature, air velocity, and contaminant concentrations, are very important to occupants' health and comfort in enclosed spaces. When point data is collected for interpolation to form field distributions, the sampling locations (the locations of the point sensors) have a significant effect on time invested, labor costs and measuring accuracy on field interpolation. This investigation compared two different sampling methods: the grid method and the gradient-based method, for determining sampling locations. The two methods were applied to obtain point air parameter data in an office room and in a section of an economy-class aircraft cabin. The point data obtained was then interpolated to form field distributions by the ordinary Kriging method. Our error analysis shows that the gradient-based sampling method has 32.6% smaller error of interpolation than the grid sampling method. We acquired the function between the interpolation errors and the sampling size (the number of sampling points). According to the function, the sampling size has an optimal value and the maximum sampling size can be determined by the sensor and system errors. This study recommends the gradient-based sampling method for measuring indoor air distributions.

  18. Bioassay vs. Air Sampling: Practical Guidance and Experience at Hanford

    SciTech Connect

    Carbaugh, Eugene H.; Carlson, Eric W.; Hill, Robin L.

    2004-02-08

    The Hanford Site has implemented a policy to guide in determining whether air sampling data or special fecal bioassay data are more appropriate for determining doses of record for low-level plutonium exposures. The basis for the policy and four years of experience in comparing DAC-hours exposure with bioassay-based dosimetry is discussed.

  19. TETHERED BALLOON SAMPLING SYSTEMS FOR MONITORING AIR POLLUTION

    EPA Science Inventory

    The paper is an overview of recent studies in which balloons, usually tethered, have been used to investigate the structure and air quality of the planetary boundary layer. It also describes a number of lightweight tethered balloon sampling systems, developed to investigate parti...

  20. A sensitive and efficient method for trace analysis of some phenolic compounds using simultaneous derivatization and air-assisted liquid-liquid microextraction from human urine and plasma samples followed by gas chromatography-nitrogen phosphorous detection.

    PubMed

    Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza; Alizadeh Nabil, Ali Akbar

    2015-12-01

    In present study, a simultaneous derivatization and air-assisted liquid-liquid microextraction method combined with gas chromatography-nitrogen phosphorous detection has been developed for the determination of some phenolic compounds in biological samples. The analytes are derivatized and extracted simultaneously by a fast reaction with 1-flouro-2,4-dinitrobenzene under mild conditions. Under optimal conditions low limits of detection in the range of 0.05-0.34 ng mL(-1) are achievable. The obtained extraction recoveries are between 84 and 97% and the relative standard deviations are less than 7.2% for intraday (n = 6) and interday (n = 4) precisions. The proposed method was demonstrated to be a simple and efficient method for the analysis of phenols in biological samples. PMID:26014445

  1. A Cryosampler Payload for Aseptic Air Sample Collection at Stratospheric Altitudes Using Balloons.

    NASA Astrophysics Data System (ADS)

    Sreenivasan, S.; Dutt, C. B. S.; Bhargava, P.; Shivaji, S.; Manchanda, R. K.

    A balloon borne Astrobiology program is being conducted from the National Balloon Facility of the Tata Institute of Fundamental Research at Hyderabad India in which a liquid Neon cooled cryo pump collects air samples under sterile conditions in the altitude regime 19 - 41 Km Pursuant to the encouraging results obtained from an earlier experiment conducted on January 2001 a new payload was configured and the balloon flight was conducted on April 20 2005 after implementing much more rigorous and enhanced sterilization protocol to completely rule out contamination from ground Air samples were collected in the altitude region 20 - 41 Km and are under analysis in the National laboratories in India for detecting the presence of living microbial cells In this paper we discuss the design and fabrication of the air sample collection probes the stringent sterilization protocol evolved for ensuring that the probes are aseptic before the commencement of the experiment and the sample retrival methods for analysis in the laboratory

  2. Can car air filters be useful as a sampling medium for air pollution monitoring purposes?

    PubMed

    Katsoyiannis, Athanasios; Birgul, Askin; Ratola, Nuno; Cincinelli, Alessandra; Sweetman, Andy J; Jones, Kevin C

    2012-11-01

    Urban air quality and real human exposure to chemical environmental stressors is an issue of high scientific and political interest. In an effort to find innovative and inexpensive means for air quality monitoring, the ability of car engine air filters (CAFs) to act as efficient samplers collecting street level air, to which people are exposed to, was tested. In particular, in the case of taxis, air filters are replaced after regular distances, the itineraries are almost exclusively urban, cruising mode is similar and, thus, knowledge of the air flow can provide with an integrated city air sample. The present pilot study focused on polycyclic aromatic hydrocarbons (PAHs), the most important category of organic pollutants associated with traffic emissions. Concentrations of ΣPAHs in CAFs ranged between 650 and 2900 μg CAF(-1), with benzo[b]fluoranthene, benzo[k]fluoranthene and indeno[123-cd]pyrene being the most abundant PAHs. Benzo[a]pyrene (BaP) ranged between 110 and 250 μg CAF(-1), accounting regularly for 5-15% of the total carcinogenic PAHs. The CAF PAH loads were used to derive road-level atmospheric PAH concentrations from a standard formula relating to the CAF air flow. Important parameters/assumptions for these estimates are the cruising speed and the exposure duration of each CAF. Based on information obtained from the garage experts, an average 'sampled air volume' of 48,750 m(3) per CAF was estimated, with uncertainty in this calculation estimated to be about a factor of 4 between the two extreme scenarios. Based on this air volume, ΣPAHs ranged between 13 and 56 ng m(-3) and BaP between 2.1 and 5.0 ng m(-3), suggesting that in-traffic BaP concentrations can be many times higher than the limit values set by the UK (0.25 ng m(-3)) and the European Union (1.0 ng m(-3)), or from active sampling stations normally cited on building roof tops or far from city centres. Notwithstanding the limitations of this approach, the very low cost, the continuous

  3. RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY AIR FILTER SAMPLES

    SciTech Connect

    Maxwell, S.; Noyes, G.; Culligan, B.

    2010-02-03

    A new rapid method for the determination of actinides and strontium in air filter samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations. The actinides and strontium in air filter method utilizes a rapid acid digestion method and a streamlined column separation process with stacked TEVA, TRU and Sr Resin cartridges. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha emitters are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The purified {sup 90}Sr fractions are mounted directly on planchets and counted by gas flow proportional counting. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency air filter samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinide and {sup 90}Sr in air filter results were reported in {approx}4 hours with excellent quality.

  4. 40 CFR 86.1775-99 - Exhaust sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Exhaust sample analysis. 86.1775-99 Section 86.1775-99 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Trucks § 86.1775-99 Exhaust sample analysis. The following requirements shall apply to TLEVs, LEVs,...

  5. 40 CFR 86.240-94 - Exhaust sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Exhaust sample analysis. 86.240-94 Section 86.240-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.240-94 Exhaust sample analysis....

  6. 40 CFR 86.540-90 - Exhaust sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Exhaust sample analysis. 86.540-90 Section 86.540-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... 1978 and Later New Motorcycles; Test Procedures § 86.540-90 Exhaust sample analysis. The...

  7. [Environmental investigation of ground water contamination at Wright-Patterson Air Force Base, Ohio]. Volume 3, Appendix A, Draft standard operating procedures and elements: Sampling and Analysis Plan (SAP): Phase 1, Task 4, Field Investigation, Draft

    SciTech Connect

    Not Available

    1991-10-01

    This report presents information concerning field procedures employed during the monitoring, well construction, well purging, sampling, and well logging at the Wright-Patterson Air Force Base. Activities were conducted in an effort to evaluate ground water contamination.

  8. 340 Representative sampling verification tank sampling and analysis plan

    SciTech Connect

    Olander, A.R., Westinghouse Hanford

    1996-08-07

    This Sampling and Analysis Plan contains requirements for characterizing the 340 vault tank 1. The objective of the sampling and characterization is to determine if the tank is homogeneous when agitated and which sampling method provides the most representative sample. A secondary objective is to collect and characterize solid samples.

  9. 340 Representative sampling verification tank sampling and analysis plan

    SciTech Connect

    Olander, A.R., Westinghouse Hanford

    1996-08-21

    This Sampling and Analysis Plan contains requirements for characterizing the 340 vault tank 1. The objective of the sampling and characterization is to determine if the tank is homogeneous when agitated and which sampling method provides the most representative sample. A secondary objective is to collect and characterize solid samples.

  10. 340 representative sampling verification tank sampling and analysis plan

    SciTech Connect

    Halgren, D.L., Westinghouse Hanford

    1996-09-09

    This Sampling and Analysis Plan contains requirements for characterizing the 340 vault tank 1. The objective of the sampling and characterization is to determine if the tank is homogeneous when agitated and which sampling method provides the most representative sample. A secondary objective is to collect and characterize solid samples.

  11. Metaproteomic analysis of atmospheric aerosol samples.

    PubMed

    Liu, Fobang; Lai, Senchao; Reinmuth-Selzle, Kathrin; Scheel, Jan Frederik; Fröhlich-Nowoisky, Janine; Després, Viviane R; Hoffmann, Thorsten; Pöschl, Ulrich; Kampf, Christopher J

    2016-09-01

    Metaproteomic analysis of air particulate matter provides information about the abundance and properties of bioaerosols in the atmosphere and their influence on climate and public health. We developed and applied efficient methods for the extraction and analysis of proteins from glass fiber filter samples of total, coarse, and fine particulate matter. Size exclusion chromatography was applied to remove matrix components, and sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) was applied for protein fractionation according to molecular size, followed by in-gel digestion and LC-MS/MS analysis of peptides using a hybrid Quadrupole-Orbitrap MS. Maxquant software and the Swiss-Prot database were used for protein identification. In samples collected at a suburban location in central Europe, we found proteins that originated mainly from plants, fungi, and bacteria, which constitute a major fraction of primary biological aerosol particles (PBAP) in the atmosphere. Allergenic proteins were found in coarse and fine particle samples, and indications for atmospheric degradation of proteins were observed. Graphical abstract Workflow for the metaproteomic analysis of atmospheric aerosol samples. PMID:27411545

  12. Artifact peroxides produced during cryogenic sampling of ambient air

    NASA Astrophysics Data System (ADS)

    Staffelbach, Thomas; Neftel, Albrecht; Dasgupta, Purnendu K.

    Peroxides were found to be produced as artifacts during cryogenic sampling with Horibe traps. Cryogenic trap sampling was compared to collection with a wet effluent diffusion denuder and a Nafion membrane diffusion denuder. Hydrogen peroxide and hydroxymethyl hydroperoxide measured in the cryogenic trap samples were significantly higher. In comparison, no evidence of artifact methyl hydroperoxide production was found. The amount of artifact H2O2 and HMHP produced increased with decreasing trap temperature. Spiking ambient air with ethene or isoprene showed that these hydrocarbons, in the presence of ozone, can be responsible for the artifact production of peroxides. Our results clearly suggest that the peroxide data obtained by cryogenic sampling and reported in the literature should be interpreted with caution.

  13. Energy analysis sample building data

    NASA Astrophysics Data System (ADS)

    1981-03-01

    Sample building data for energy calculations necessary for the comparative analysis between the proposed energy calculation procedure and the procedures using comprehensive hourly simulation of HVAC systems are presented. The comparison calculation includes data for the terminal reheat system, double-duct system, heat reclaim system, and standard VAV system for a hypothetical 20-story office building in Washington, DC. Each is evaluated in conjunction with electric centrifugal chiller and gas-fired boiler.

  14. Pesticide detection in air samples from contrasted houses and in their inhabitants' hair.

    PubMed

    Raeppel, Caroline; Salquèbre, Guillaume; Millet, Maurice; Appenzeller, Brice M R

    2016-02-15

    In order to identify associations between indoor air contamination and human exposure to pesticides, hair samples from 14 persons (9 adults and 5 children below 12 years) were collected simultaneously with the air of their 5 contrasted houses. Three houses were situated in Alsace (France), one in Lorraine (France) and one in Luxembourg (Luxembourg). Houses were located in urban (n=3), semi-urban (n=1) and rural areas (n=1). Twenty five (25) pesticides were detected at least once in indoor air samples and 20 pesticides were detected at least once in hair samples. The comparison between hair and air samples for the same sampling periods shows that pesticides detected in the two matrices were not necessarily associated. Exposure profiles varied from one home to another but also between inhabitants of the same home, suggesting that exposure can be different between inhabitants of the same home. This study demonstrated the usefulness and the complementarity of hair analysis, for the personalized biomonitoring of people exposure to pesticides, and air analysis, for the identification of airborne exposure and house contamination. PMID:26706757

  15. Ambient Air Sampling During Quantum-dot Spray Deposition

    SciTech Connect

    Jankovic, John Timothy; Hollenbeck, Scott M

    2010-01-01

    Ambient air sampling for nano-size particle emissions was performed during spot spray coating operations with a Sono-Tek Exactacoat Benchtop system (ECB). The ECB consisted of the application equipment contained within an exhaust enclosure. The enclosure contained numerous small access openings, including an exhaust hook-up. Door access comprised most of the width and height of the front. The door itself was of the swing-out type. Two types of nanomaterials, Cadmium selenide (Cd-Se) quantum-dots (QDs) and Gold (Au) QDs, nominally 3.3 and 5 nm in diameter respectively, were applied during the evaluation. Median spray drop size was in the 20 to 60 micrometer size range.1 Surface coating tests were of short duration, on the order of one-half second per spray and ten spray applications between door openings. The enclosure was ventilated by connection to a high efficiency particulate aerosol (HEPA) filtered house exhaust system. The exhaust rate was nominally 80 ft3 per minute producing about 5 air changes per minute. Real time air monitoring with a scanning mobility particle size analyzer (SMPS ) with a size detection limit of 7 nm indicated a significant increase in the ambient air concentration upon early door opening. A handheld condensation particle counter (CPC) with a lower size limit of 10 nm did not record changes in the ambient background. This increase in the ambient was not observed when door opening was delayed for 2 minutes (~10 air changes). The ventilated enclosure controlled emissions except for cases of rapid door opening before the overspray could be removed by the exhaust. A time delay sufficient to provide 10 enclosure air changes (a concentration reduction of more than 99.99 %) before door opening prevented the release of aerosol particles in any size.2 Scanning-transmission electron microscopy (STEM) and atomic force microscopy (AFM) demonstrated the presence of agglomerates in the surfaces of the spray applied deposition. A filtered air sample of

  16. Evaluation of official air sampling methodologies in Ukraine

    SciTech Connect

    Nakonechniy, J.J.; Wadden, R.A.; Scheff, P.A.; Suero, M.

    1997-12-31

    In conjunction with an environmental epidemiology study of the health of Ukrainian children, a significant amount of air pollution measurement data was gathered from government agencies. The areas of interest were the industrial city of Dneprodzherzhinsk; and the Dniprovsky region of Kyiv. The data were for 1993 and, for some of the monitoring stations, 1994. The pollutants reported included dust (approximately equivalent to TSP, total suspended particulate matter), SO{sub 2}, CO, NO{sub 2}, NO, H{sub 2}S, phenol, HCl, NH{sub 3}, formaldehyde, BaP, and lead. The ultimate goal was to evaluate whether existing historical data are appropriate for developing measures of human exposure. In order to evaluate the data it was necessary to understand the sampling and analytical methodologies which were used. Small sample volumes coupled with dated analytical procedures resulted in very poor precision and detection limits for most of the measured pollutants. The measurement of particulate matter is a good example of the limits imposed by the sampling methodology. The short sample time (20 min), small sample volume (150 lpm), and limited analytical balances (0.5 mg resolution) result in a minimum lower limit of detection of 0.25 mg/m{sup 3}. For example at Kyiv Station 3 in 1993, only one of 545 measurements exceeded 0.2 mg/m{sup 3}. This minimum detectable quantity is over three times the former US annual TSP standard. In addition, even when operated on a 24-hour basis in the US, it has been shown that the sampling method only collected approximately 34% of that collected by a co-located hi-vol sampler. Consequently, official air pollution data for suspended dust are likely to severely under-represent actual ambient concentrations. Data for other pollutants are presented and sampling and analytical methods are similarly compared with Western methods in common use.

  17. Passive air sampling of gaseous elemental mercury: a critical review

    NASA Astrophysics Data System (ADS)

    McLagan, David S.; Mazur, Maxwell E. E.; Mitchell, Carl P. J.; Wania, Frank

    2016-03-01

    Because gaseous elemental mercury (GEM) is distributed globally through the atmosphere, reliable means of measuring its concentrations in air are important. Passive air samplers (PASs), designed to be cheap, simple to operate, and to work without electricity, could provide an alternative to established active sampling techniques in applications such as (1) long-term monitoring of atmospheric GEM levels in remote regions and in developing countries, (2) atmospheric mercury source identification and characterization through finely resolved spatial mapping, and (3) the recording of personal exposure to GEM. An effective GEM PAS requires a tightly constrained sampling rate, a large and stable uptake capacity, and a sensitive analytical technique. None of the GEM PASs developed to date achieve levels of accuracy and precision sufficient for the reliable determination of background concentrations over extended deployments. This is due to (1) sampling rates that vary due to meteorological factors and manufacturing inconsistencies, and/or (2) an often low, irreproducible and/or unstable uptake capacity of the employed sorbents. While we identify shortcomings of existing GEM PAS, we also reveal potential routes to overcome those difficulties. Activated carbon and nanostructured metal surfaces hold promise as effective sorbents. Sampler designs incorporating diffusive barriers should be able to notably reduce the influence of wind on sampling rates.

  18. Passive air sampling of gaseous elemental mercury: a critical review

    NASA Astrophysics Data System (ADS)

    McLagan, D. S.; Mazur, M. E. E.; Mitchell, C. P. J.; Wania, F.

    2015-12-01

    Because gaseous elemental mercury (GEM) is distributed globally through the atmosphere, reliable means of measuring its concentrations in air are important. Passive air samplers (PASs), designed to be cheap, simple to operate, and to work without electricity, could provide an alternative to established active sampling techniques in applications such as (1) long term monitoring of atmospheric GEM levels in remote regions and in developing countries, (2) atmospheric mercury source identification and characterisation through finely-resolved spatial mapping, and (3) the recording of personal exposure to GEM. An effective GEM PAS requires a tightly constrained sampling rate, a large and stable uptake capacity, and a sensitive analytical technique. None of the GEM PASs developed to date achieves levels of accuracy and precision sufficient for the reliable determination of background concentrations over extended deployments. This is due to (1) sampling rates that vary due to meteorological factors and manufacturing inconsistencies and/or (2) an often low, irreproducible and/or unstable uptake capacity of the employed sorbents. While we identify shortcomings of existing GEM PAS, we also reveal potential routes to overcome those difficulties. Activated carbon and nano-structured metal surfaces hold promise as effective sorbents. Sampler designs incorporating diffusive barriers should be able to notably reduce the influence of wind on sampling rates.

  19. Environmental sampling and analysis in support of NTI-3

    SciTech Connect

    McGuire, R.R.; Harrar, J.E.; Haas, J.S.; Eagle, R.J.; Andresen, B.D.

    1991-04-06

    The third National Trail Inspection took place at the Monsanto Chemical Plant in Luling, Louisiana. In order to test the effectiveness of environmental sampling (soil, water and air) in determining the nature of the chemical process in a given production plant and to examine the distance from a process building that samples can effectively be taken, we needed to select some materials that constituted components of process streams. Three materials were selected: 1. isopropyl amine for air monitoring, 2. 4-nitrophenol, one of the precursors in the acetaminophen process, and 3. an intermediate in the production of glyphosate for ROUNDUP that is known simply as glyphosate intermediated. LLNL did not participate in the air sampling nor the analysis for isopropyl amine. This paper discussed the steps in this experiment including sample collection, sample workshop, sample analysis the results and discussion and the conclusion. 3 figs., 6 tabs.

  20. Determination of radiocarbon in stratospheric CO2, obtained through AirCore sampling.

    NASA Astrophysics Data System (ADS)

    Paul, Dipayan; Chen, Huilin; Been, Henk A.; Kivi, Rigel; Meijer, Harro A. J.

    2016-04-01

    The concentration of Greenhouse Gases (GHG), with carbon dioxide as the most prominent example, has been and still is increasing, predominantly due to emissions from fossil fuel combustion. CO2 is also the most important component of the global carbon cycle. Among other tracers, radiocarbon (Carbon-14) is a unique and an important atmospheric tracer used in the understanding of the global carbon cycle. Radiocarbon is a naturally occurring isotope (radioactive, t 1/2 = 5730 ± 40 years) of carbon produced through the interaction of thermalized neutrons and nitrogen in the upper atmosphere. Generally, for performing atmospheric radiocarbon measurements in the higher atmosphere, large samples (few liters of air) were collected using aircrafts and balloons. However, collecting stratospheric samples on a regular basis for radiocarbon analysis is extremely expensive. Here we describe the determination of radiocarbon concentrations in stratospheric CO2, collected using AirCore sampling. AirCore is an innovative sampling technique for obtaining vertical atmospheric profiles and, in Europe, is done on a regular basis at Sodankylä, Finland for CO2, CH4 and CO. The stratospheric parts of two such AirCore profiles were used in this study as a proof-of-principle. CO2 from the stratospheric air samples were extracted and converted to elemental carbon, which were then measured at the Accelerator Mass Spectrometric (AMS) facility of the Centre for Isotope Research (CIO) at the University of Groningen. The stratospheric part of the AirCore profile was divided into six sections, each contained approximately 10 μg C. A detailed description of the extraction, graphitization, AMS analysis and the derivation of the stratospheric radiocarbon profile will be the main focus. Through our results, we will show that AirCore is a viable sampling method for performing high-precision radiocarbon measurements of stratospheric CO2 with reasonably good spatial resolution on a regular basis

  1. CONVENIENT SAMPLING OF AIR BACTERIA IN OPERATING ROOMS.

    PubMed

    WARNER, P; GLASSCO, A; KROEKER, J

    1964-02-22

    A convenient arrangement for sampling air bacteria in operating rooms with a slit sampler (the Fort Detrick sampler) is described. Its purpose is to contribute as far as possible to the convenience of the surgical staff and thereby to the safety of the patient. It has the advantages of recording minute-to-minute changes in bacterial air count; it is unobtrusive and yet can be continually observed by a technician; it is not noisy and avoids the dangers of explosion and static electricity; it is inexpensive, and parts are easily replaced; and finally it provides a means of keeping permanent photographic records of bacterial counts. Results of a preliminary trial of this method appeared to be satisfactory. PMID:14118695

  2. Survey of volatile organic compounds found in indoor and outdoor air samples from Japan.

    PubMed

    Tanaka-Kagawa, Toshiko; Uchiyama, Shigehisa; Matsushima, Erika; Sasaki, Akira; Kobayashi, Hiroshi; Kobayashi, Hiromi; Yagi, Masahiro; Tsuno, Masahiko; Arao, Masa; Ikemoto, Kazumi; Yamasaki, Makoto; Nakashima, Ayako; Shimizu, Yuri; Otsubo, Yasufumi; Ando, Masanori; Jinno, Hideto; Tokunaga, Hiroshi

    2005-01-01

    Indoor air quality is currently a growing concern, mainly due to the incidence of sick building syndrome and building related illness. To better understand indoor air quality in Japan, both indoor and outdoor air samples were collected from 50 residences in Iwate, Yamanashi, Shiga, Hyogo, Kochi and Fukuoka Prefectures. More than 100 volatile organic compounds (VOCs) were analyzed by thermal desorption-gas chromatography/mass spectrometry method. The most abundant class of compounds present in the indoor air samples were identified (i.e. alkanes, alkylbenzenes and terpenes). For 30% of the indoor air samples, the sum of each VOC exceeded the current provisional guideline value for total VOC (TVOC, 400 microg/m3). The major component of these samples included linear and branched-chain alkanes (possibly derived from fossil fuels), 1,4-dichlorobenzene (a moth repellent), alpha-pinene (emission from woody building materials) and limonene (probably derived from aroma products). As an unexpected result, one residence was polluted with an extremely high concentration of 1,1,1,2-tetrafluoroethane (720 microg/m3), suggesting accidental leakage from a household appliance such as a refrigerator. The results presented in this paper are important in establishing the Japanese target compound list for TVOC analysis, as well as defining the current status of indoor air quality in Japan. PMID:16541748

  3. NON-POLAR VOLATILE ORGANIC COMPOUNDS IN WHOLE AIR SAMPLES FROM THE AUTOEX STUDIES

    EPA Science Inventory

    Air samples were captured in SUMMA polished stainless steel canisters and returned to the laboratory for analysis of trace level volatile organic compounds by gas chromatography - mass spectrometry. ampling was performed over 2-hour periods at various distances from heavily trave...

  4. Toxicological Assessment of ISS Air Quality: Contingency Sampling - February 2013

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie

    2013-01-01

    Two grab sample containers (GSCs) were collected by crew members onboard ISS in response to a vinegar-like odor in the US Lab. On February 5, the first sample was collected approximately 1 hour after the odor was noted by the crew in the forward portion of the Lab. The second sample was collected on February 22 when a similar odor was noted and localized to the end ports of the microgravity science glovebox (MSG). The crewmember removed a glove from the MSG and collected the GSC inside the glovebox volume. Both samples were returned on SpaceX-2 for ground analysis.

  5. Evaluation of Urban Air Quality By Passive Sampling Technique

    NASA Astrophysics Data System (ADS)

    Nunes, T. V.; Miranda, A. I.; Duarte, S.; Lima, M. J.

    Aveiro is a flat small city in the centre of Portugal, close to the Atlantic coast. In the last two decades an intensive development of demographic, traffic and industry growth in the region was observed which was reflected on the air quality degrada- tion. In order to evaluate the urban air quality in Aveiro, a field-monitoring network by passive sampling with high space resolution was implemented. Twenty-four field places were distributed in a area of 3x3 Km2 and ozone and NO2 concentrations were measured. The site distribution density was higher in the centre, 250x250 m2 than in periphery where a 500x500 m2 grid was used. The selection of field places took into consideration the choice criteria recommendation by United Kingdom environmental authorities, and three tubes and a blank tube for each pollutant were used at each site. The sampling system was mounted at 3m from the ground usually profiting the street lampposts. Concerning NO2 acrylic tubes were used with 85 mm of length and an in- ternal diameter of 12mm, where in one of the extremities three steel grids impregnated with a solution of TEA were placed and fixed with a polyethylene end cup (Heal et al., 1999); PFA Teflon tube with 53 mm of length and 9 mm of internal diameter and three impregnated glass filters impregnated with DPE solution fixed by a teflon end cup was used for ozone sampling (Monn and Hargartner, 1990). The passive sampling method for ozone and nitrogen dioxide was compared with continuous measurements, but the amount of measurements wasnSt enough for an accurate calibration and validation of the method. Although this constraint the field observations (June to August 2001) for these two pollutants assign interesting information about the air quality in the urban area. A krigger method of interpolation (Surfer- Golden Software-2000) was applied to field data to obtain isolines distribution of NO2 and ozone concentration for the studied area. Even the used passive sampling method has many

  6. Versatile microanalytical system with porous polypropylene capillary membrane for calibration gas generation and trace gaseous pollutants sampling applied to the analysis of formaldehyde, formic acid, acetic acid and ammonia in outdoor air.

    PubMed

    Coelho, Lúcia H G; Melchert, Wanessa R; Rocha, Flavio R; Rocha, Fábio R P; Gutz, Ivano G R

    2010-11-15

    The analytical determination of atmospheric pollutants still presents challenges due to the low-level concentrations (frequently in the μg m(-3) range) and their variations with sampling site and time. In this work, a capillary membrane diffusion scrubber (CMDS) was scaled down to match with capillary electrophoresis (CE), a quick separation technique that requires nothing more than some nanoliters of sample and, when combined with capacitively coupled contactless conductometric detection (C(4)D), is particularly favorable for ionic species that do not absorb in the UV-vis region, like the target analytes formaldehyde, formic acid, acetic acid and ammonium. The CMDS was coaxially assembled inside a PTFE tube and fed with acceptor phase (deionized water for species with a high Henry's constant such as formaldehyde and carboxylic acids, or acidic solution for ammonia sampling with equilibrium displacement to the non-volatile ammonium ion) at a low flow rate (8.3 nL s(-1)), while the sample was aspirated through the annular gap of the concentric tubes at 2.5 mL s(-1). A second unit, in all similar to the CMDS, was operated as a capillary membrane diffusion emitter (CMDE), generating a gas flow with know concentrations of ammonia for the evaluation of the CMDS. The fluids of the system were driven with inexpensive aquarium air pumps, and the collected samples were stored in vials cooled by a Peltier element. Complete protocols were developed for the analysis, in air, of NH(3), CH(3)COOH, HCOOH and, with a derivatization setup, CH(2)O, by associating the CMDS collection with the determination by CE-C(4)D. The ammonia concentrations obtained by electrophoresis were checked against the reference spectrophotometric method based on Berthelot's reaction. Sensitivity enhancements of this reference method were achieved by using a modified Berthelot reaction, solenoid micro-pumps for liquid propulsion and a long optical path cell based on a liquid core waveguide (LCW). All

  7. Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards

    SciTech Connect

    Glissmeyer, John A.; Flaherty, Julia E.; Pekour, Mikhail S.

    2014-12-02

    The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system must also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer

  8. Sample Manipulation System for Sample Analysis at Mars

    NASA Technical Reports Server (NTRS)

    Mumm, Erik; Kennedy, Tom; Carlson, Lee; Roberts, Dustyn

    2008-01-01

    The Sample Analysis at Mars (SAM) instrument will analyze Martian samples collected by the Mars Science Laboratory Rover with a suite of spectrometers. This paper discusses the driving requirements, design, and lessons learned in the development of the Sample Manipulation System (SMS) within SAM. The SMS stores and manipulates 74 sample cups to be used for solid sample pyrolysis experiments. Focus is given to the unique mechanism architecture developed to deliver a high packing density of sample cups in a reliable, fault tolerant manner while minimizing system mass and control complexity. Lessons learned are presented on contamination control, launch restraint mechanisms for fragile sample cups, and mechanism test data.

  9. Accelerator Mass Spectrometric determination of radiocarbon in stratospheric CO2, retrieved from AirCore sampling.

    NASA Astrophysics Data System (ADS)

    Paul, Dipayan; Been, Henk A.; Chen, Huilin; Kivi, Rigel; Meijer, Harro A. J.

    2015-04-01

    In this decade, understanding the impact of human activities on climate is one of the key issues of discussion globally. The continuous rise in the concentration of greenhouse gases, e.g., CO2, CH4, etc. in the atmosphere, predominantly due to human activities, is alarming and requires continuous monitoring to understand the dynamics. Radiocarbon is an important atmospheric tracer and one of the many used in the understanding of the global carbon budget, which includes the greenhouse gases like CO2 and CH4. Measurement of 14C (or radiocarbon) in atmospheric CO2 generally requires collection of large air samples (few liters) from which CO2 is extracted and then the concentration of radiocarbon is determined. Currently, Accelerator Mass Spectrometry (AMS) is the most precise, reliable and widely used technique for atmospheric radiocarbon detection. However, the regular collection of air samples from troposphere and stratosphere, for example using aircraft, is prohibitively expensive. AirCore is an innovative atmospheric sampling system, developed by NOAA. It comprises of a long tube descending from a high altitude with one end open and the other closed, and has been demonstrated to be a reliable, cost-effective sampling system for high-altitude profile (up to ~ 30 km) measurements of CH4and CO2(Karion et al. 2010). In Europe, AirCore measurements are being performed on a regular basis near Sodankylä since September 2013. Here we describe the analysis of two such AirCore samples collected in July 2014, Finland, for determining the 14C concentration in stratospheric CO2. The two AirCore samples were collected on consecutive days. Each stratospheric AirCore sample was divided into six fractions, each containing ~ 35 μg CO2 (~9.5 μg C). Each fraction was separately trapped in 1 /4 inch coiled stainless steel tubing for radiocarbon measurements. The procedure for CO2 extraction from the stratospheric air samples; the sample preparation, with samples containing < 10

  10. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 6 2011-07-01 2011-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA...

  11. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA...

  12. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 6 2012-07-01 2012-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA...

  13. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 6 2014-07-01 2014-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA...

  14. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA processing documents. (a) This section...

  15. ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

    SciTech Connect

    Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

    2011-06-07

    Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear ES

  16. Curve fitting air sample filter decay curves to estimate transuranic content.

    PubMed

    Hayes, Robert B; Chiou, Hung Cheng

    2004-01-01

    By testing industry standard techniques for radon progeny evaluation on air sample filters, a new technique is developed to evaluate transuranic activity on air filters by curve fitting the decay curves. The industry method modified here is simply the use of filter activity measurements at different times to estimate the air concentrations of radon progeny. The primary modification was to not look for specific radon progeny values but rather transuranic activity. By using a method that will provide reasonably conservative estimates of the transuranic activity present on a filter, some credit for the decay curve shape can then be taken. By carrying out rigorous statistical analysis of the curve fits to over 65 samples having no transuranic activity taken over a 10-mo period, an optimization of the fitting function and quality tests for this purpose was attained. PMID:14695010

  17. Bias in air sampling techniques used to measure inhalation exposure.

    PubMed

    Cohen, B S; Harley, N H; Lippmann, M

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and "mini hi-volume" samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. We conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages. PMID:6720582

  18. Bias in air sampling techniques used to measure inhalation exposure

    SciTech Connect

    Cohen, B.S.; Harley, N.H.; Lippmann, M.

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and mini hi-volume samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. The authors conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages.

  19. Sample Analysis Code System for the Dual Channel Counter.

    1994-09-14

    Version 00 RADCOMPT automates gross alpha and gross beta sample analysis calculations and, in many cases, warns the technologist when a hazard level is being approached or when it has been exceeded. The RADCOMPT program is unique in that it corrects for crosstalk between channels, and in this way provides increased accuracy and efficiency. Even though it is designed explicitly for the analyses of air samples and wipe samples, it can also be used formore » other sample types. It is designed to be used with a dual channel counter (in which one channel is used for alpha detection and the other for beta detection), but may be used with two single channel counters employed for the same purpose. In addition, it provides an automated means for the execution of the following radiological sample analyses protocol: A. Calibration of the counting system B. Calculation of sample activity or air activity concentrations (with the activities of air activity concentrations at the top and bottom of the two-sided 95 percent confidence interval also specified). C. Determination of minimum sample counting times required for detection and/or quantification of specified alpha and beta activities or air activity concentrations. In addition, alternate counting times are determined for alternate activities such that the specified alpha and beta activities are at the top of the 95% confidence interval, increasing the confidence that the activities measured are below the specified limits. D. Calculation of the minimum detectable activities or air activity concentrations. E. Determination of air sample volumes required for detection and/or quantification of specified alpha and beta air activity concentrations. F. Calculation of long-lived activities or air activity concentrations based on radon daughter and thoron daughter decay. G. Calculation of employees DAC-Hours and estimated Committed Effective Dose Equivalent. H. Varying calibration constants (to coincide with possible adjustments to

  20. Passive air sampling of PCBs, PBDEs, and organochlorine pesticides across Europe.

    PubMed

    Jaward, Foday M; Farrar, Nick J; Harner, Tom; Sweetman, Andrew J; Jones, Kevin C

    2004-01-01

    This study presents concurrently sampled ambient air data for a range of persistent organic pollutants at the continental scale. This was achieved using a passive air sampling system, deploying polyurethane foam disks, which was prepared in one laboratory, sealed to prevent contamination, sent out by courier to volunteers participating in different countries, exposed for 6 weeks, collected, resealed, and returned to the laboratory for analysis. Europe was the study area--a region with a history of extensive POPs usage and emission and with marked national differences in population density, the degree of urbanization and industrial/agricultural development. Samplers were deployed at remote/rural/urban locations in 22 countries and analyzed for PCBs, a range of organochlorine pesticides (HCB, alpha-HCH, gamma-HCH, ppDDT, ppDDE), and PBDEs. Calculated air concentrations were in line with those obtained by conventional active air sampling techniques. The geographical pattern of all compounds reflected suspected regional emission patterns and highlighted localized hotspots. PCB and PBDE levels varied by over 2 orders of magnitude; the highest values were detected in areas of high usage and were linked to urbanized areas. HCB was relatively uniformly distributed, reflecting its persistence and high degree of mixing in air. Higher gamma-HCH, ppDDT, and ppDDE levels generally occurred in South and East Europe. PMID:14740714

  1. Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air Part 1: Sorbent-based air monitoring options.

    PubMed

    Woolfenden, Elizabeth

    2010-04-16

    Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Target compounds range in volatility from acetylene and freons to phthalates and PCBs and include apolar, polar and reactive species. Airborne vapour concentrations will vary depending on the nature of the location, nearby pollution sources, weather conditions, etc. Levels can range from low percent concentrations in stack and vent emissions to low part per trillion (ppt) levels in ultra-clean outdoor locations. Hundreds, even thousands of different compounds may be present in any given atmosphere. GC is commonly used in combination with mass spectrometry (MS) detection especially for environmental monitoring or for screening uncharacterised workplace atmospheres. Given the complexity and variability of organic vapours in air, no one sampling approach suits every monitoring scenario. A variety of different sampling strategies and sorbent media have been developed to address specific applications. Key sorbent-based examples include: active (pumped) sampling onto tubes packed with one or more sorbents held at ambient temperature; diffusive (passive) sampling onto sorbent tubes/cartridges; on-line sampling of air/gas streams into cooled sorbent traps; and transfer of air samples from containers (canisters, Tedlar) bags, etc.) into cooled sorbent focusing traps. Whichever sampling approach is selected, subsequent analysis almost always involves either solvent extraction or thermal desorption (TD) prior to GC(/MS) analysis. The overall performance of the air monitoring method will depend heavily on appropriate selection of key sampling and analytical parameters. This comprehensive review of air monitoring using sorbent tubes/traps is divided into 2 parts. (1) Sorbent-based air sampling option. (2) Sorbent selection and other aspects of optimizing sorbent-based air monitoring methods. The paper presents

  2. Sampling and sample processing in pesticide residue analysis.

    PubMed

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion. PMID:25677085

  3. Sampling of air streams and incorporation of samples in the Microtox{trademark} toxicity testing system

    SciTech Connect

    Kleinheinz, G.T.; St. John, W.P.

    1997-10-01

    A study was conducted to develop a rapid and reliable method for the collection and incorporation of biofiltration air samples containing volatile organic compounds (VOCs) into the Microtox toxicity testing system. To date, no method exists for this type of assay. A constant stream of VOCs was generated by air stripping compounds from a complex mixture of petroleum hydrocarbons (PHCs). Samples were collected on coconut charcoal ORBO tubes and the VOCs extracted with methylene chloride. The compounds extracted were then solvent exchanged into dimethyl sulfoxide (DMSO) under gaseous nitrogen. The resulting DMSO extract was directly incorporated into the Microtox toxicity testing system. In order to determine the efficiency of the solvent exchange, the VOCs in the DMSO extract were then extracted into hexane and subsequently analyzed using gas chromatography (GC) with a flame ionization detector (FID). It was determined that all but the most volatile VOCs could be effectively transferred from the ORBO tubes to DMSO for Microtox testing. Potential trace amounts of residual methylene chloride in the DMSO extracts showed no adverse effects in the Microtox system when compared to control samples.

  4. An Autosampler and Field Sample Carrier for Maximizing Throughput Using an Open-Air, Surface Sampling Ion Source for MS

    EPA Science Inventory

    A recently developed, commercially available, open-air, surface sampling ion source for mass spectrometers provides individual analyses in several seconds. To realize its full throughput potential, an autosampler and field sample carrier were designed and built. The autosampler ...

  5. Sampling and sample processing in pesticide residue analysis

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Proper sampling and sample processing in pesticide residue analysis of food and soil has always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agroc...

  6. IWTU Process Sample Analysis Report

    SciTech Connect

    Nick Soelberg

    2013-04-01

    CH2M-WG Idaho (CWI) requested that Battelle Energy Alliance (BEA) analyze various samples collected during June – August 2012 at the Integrated Waste Treatment Facility (IWTU). Samples of IWTU process materials were collected from various locations in the process. None of these samples were radioactive. These samples were collected and analyzed to provide more understanding of the compositions of various materials in the process during the time of the process shutdown that occurred on June 16, 2012, while the IWTU was in the process of nonradioactive startup.

  7. Polybrominated diphenyl ethers and alternative flame retardants in air and precipitation samples from the northern Lake Victoria region, East Africa.

    PubMed

    Arinaitwe, Kenneth; Muir, Derek C G; Kiremire, Bernard T; Fellin, Phil; Li, Henrik; Teixeira, Camilla

    2014-01-01

    High volume air and precipitation samples were collected close to the shore of Lake Victoria at Entebbe, Uganda, between October 2008 and July 2010 inclusive. Polybrominated diphenyl ethers (PBDEs) and alternative flame retardants (AFRs) were analyzed by GC-MS. BDEs 47, 99, and 209 were the predominant PBDEs with mean concentrations (in air) of 9.84, 4.38, 8.27 pg m(-3) and mean fluxes in precipitation of 3.40, 6.23, and 7.82 ng m(-2) sample(-1), respectively. 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), and hexabromocyclododecane (HBCDD), anti- and syn-Dechlorane plus were detected at levels comparable with those of PBDEs. Both PBDEs and AFRs in air generally increased from 2008 to 2010. Elevated PBDE concentrations in air were associated with slow moving low altitude air masses from the region immediately adjacent to the lake, while low concentrations were mostly associated with fast moving westerly and southwesterly air masses. Analysis of the octa- and nona-BDE profiles suggested photolysis and pyrolytic debromination of BDE-209 in the air samples. The highly halogenated and most abundant PBDEs and AFRs in air also predominated in precipitation samples. This is the first study to report flame retardants in high volume air samples and precipitation in Equatorial Africa. PMID:24400732

  8. FIELD SAMPLING PROTOCOLS AND ANALYSIS

    EPA Science Inventory

    I have been asked to speak again to the environmental science class regarding actual research scenarios related to my work at Kerr Lab. I plan to discuss sampling protocols along with various field analyses performed during sampling activities. Many of the students have never see...

  9. Visual Analysis of Air Traffic Data

    NASA Technical Reports Server (NTRS)

    Albrecht, George Hans; Pang, Alex

    2012-01-01

    In this paper, we present visual analysis tools to help study the impact of policy changes on air traffic congestion. The tools support visualization of time-varying air traffic density over an area of interest using different time granularity. We use this visual analysis platform to investigate how changing the aircraft separation volume can reduce congestion while maintaining key safety requirements. The same platform can also be used as a decision aid for processing requests for unmanned aerial vehicle operations.

  10. Air sampling filtration media: Collection efficiency for respirable size-selective sampling

    PubMed Central

    Soo, Jhy-Charm; Monaghan, Keenan; Lee, Taekhee; Kashon, Mike; Harper, Martin

    2016-01-01

    The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 μm pore sizes), polycarbonate (0.4, 0.8, 2, and 5 μm pore sizes), polytetrafluoroethylene (PTFE; 0.45, 1, 2, and 5 μm pore sizes), polyvinyl chloride (PVC; 0.8 and 5 μm pore sizes), and silver membrane (0.45, 0.8, 1.2, and 5 μm pore sizes) filters were exposed to polydisperse sodium chloride (NaCl) particles in the size range of 10–400 nm. Test aerosols were nebulized and introduced into a calm air chamber through a diffusion dryer and aerosol neutralizer. The testing filters (37 mm diameter) were mounted in a conductive polypropylene filter-holder (cassette) within a metal testing tube. The experiments were conducted at flow rates between 1.7 and 11.2 l min−1. The particle size distributions of NaCl challenge aerosol were measured upstream and downstream of the test filters by a scanning mobility particle sizer (SMPS). Three different filters of each type with at least three repetitions for each pore size were tested. In general, the collection efficiency varied with airflow, pore size, and sampling duration. In addition, both collection efficiency and pressure drop increased with decreased pore size and increased sampling flow rate, but they differed among filter types and manufacturer. The present study confirmed that the MCE, PTFE, and PVC filters have a relatively high collection efficiency for challenge particles much smaller than their nominal pore size and are considerably more efficient than polycarbonate and silver membrane filters, especially at larger nominal pore sizes. PMID:26834310

  11. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF METALS FROM SOIL, DUST, AIR FILTER, AND SURFACE AND DERMAL WIPE SAMPLES FOR AA (GRAPHITE FURNACE OR FLAME) OR ICP-AES ANALYSIS (BCO-L-3.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the acid digestion of soil, house dust, air filter, and surface or dermal wipe samples for analysis using inductively coupled plasma atomic emissions spectrometry (ICP-AES) and/or graphite furnace atomic absorption spectrometry (GFAAS) or fl...

  12. Evaluation of passive air sampler calibrations: Selection of sampling rates and implications for the measurement of persistent organic pollutants in air

    NASA Astrophysics Data System (ADS)

    Melymuk, Lisa; Robson, Matthew; Helm, Paul A.; Diamond, Miriam L.

    2011-04-01

    Polyurethane foam (PUF) passive air samplers (PAS) are a common and highly useful method of sampling persistent organic pollutants (POP) concentrations in air. PAS calibration is necessary to obtain reasonable and comparable semi-quantitative measures of air concentrations. Various methods are found in the literature concerning PAS calibration. 35 studies on PAS use and calibration are examined here, in conjunction with a study involving 10 PAS deployed concurrently in outdoor air with a low-volume air sampler in order to measure the sampling rates of PUF-PAS for polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), polycyclic musks (PCMs), and polycyclic aromatic hydrocarbons (PAHs). Based on this analysis it is recommended that (1) PAS should be assumed to represent bulk rather than gas-phase compound concentrations due to the sampling of particle-bound compounds, (2) calibration of PAS sampling rates is more accurately achieved using an active low-volume air sampler rather than depuration compounds since the former measures gas- and particle-phase compounds and does so continuously over the deployment period of the PAS, and (3) homolog-specific sampling rates based on KOA groupings be used in preference to compound/congener-specific or single sampling rates.

  13. The use of Whatman-41 filters for high volume air sampling

    NASA Technical Reports Server (NTRS)

    Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.

    1975-01-01

    The feasibility of using W41 filter media on a routine TSP high-volume monitoring network was determined by comparison with glass fiber (GF) filtering. Results indicate that suspended particulate samples from GF filters averaged slightly, but not significantly, higher than those from Whatman-41 filters. Some extra handling procedures were required to avoid errors due to the hygroscopic nature of W41 filters; these added procedures are not overly burdensome, however, and they allow the performance of analytical work, thus extending the capabilities of high-volume sampling. It was demonstrated that W41 filters are practical for air quality monitoring and elemental analysis in environments similar to Cleveland's.

  14. High sensitivity gamma spectrometry of air samples near SRS during 1985-1995

    SciTech Connect

    Winn, W.G.; Cadieux, J.R.

    1997-07-01

    High sensitivity gamma analysis of off-site air samples near the Savannah River Site (SRS) is achieved by collecting large volume air samples for analysis by ultra-low-level gamma spectrometry. A review of the 1985-1995 measurements has highlighted local and distant releases of man-made radionuclides, along with cosmogenic radionuclides which correlate with both solar and seasonal phenomena. Measurements typically involve 2-day air collection of a 70,000 m{sup 3} sample on a 51 cm x 51 cm cellulose filter using a high-capacity pump. Short-lived radon background activity is allowed to decay a few days, and then the filter is configured into a smaller calibrated volume and counted 1-3 days on a 30 percent-efficient HPGe in the Ultra-Low-Level Counting Facility. Representative detection limits for this method are shown in Table 1, and even lower limits are achievable by counting on the low-background 160 percent-efficient HPGe of the Underground Counting Facility.

  15. Determination of methyl bromide in air samples by headspace gas chromatography

    SciTech Connect

    Woodrow, J.E.; McChesney, M.M.; Seiber, J.N.

    1988-03-01

    Methyl bromide is extensively used in agriculture (4 x 10/sup 6/ kg for 1985 in California alone as a fumigant to control nematodes, weeds, and fungi in soil and insect pests in harvested grains and nuts. Given its low boiling point (3.8/sup 0/C) and high vapor pressure (approx. 1400 Torr at 20/sup 0/C), methyl bromide will readily diffuse if not rigorously contained. Methods for determining methyl bromide and other halocarbons in air vary widely. A common practice is to trap the material from air on an adsorbent, such as polymeric resins, followed by thermal desorption either directly into the analytical instrumentation or after intermediary cryofocusing. While in some cases analytical detection limits were reasonable (parts per million range), many of the published methods were labor intensive and required special handling techniques that precluded high sample throughput. They describe here a method for the sampling and analysis of airborne methyl bromide that was designed to handle large numbers of samples through automating some critical steps of the analysis. The result was a method that allowed around-the-clock operation with a minimum of operator attention. Furthermore, the method was not specific to methyl bromide and could be used to determine other halocarbons in air.

  16. Sample processor for chemical analysis

    NASA Technical Reports Server (NTRS)

    Boettger, Heinz G. (Inventor)

    1980-01-01

    An apparatus is provided which can process numerous samples that must be chemically analyzed by the application of fluids such as liquid reagents, solvents and purge gases, as well as the application of dumps for receiving the applied fluid after they pass across the sample, in a manner that permits numerous samples to be processed in a relatively short time and with minimal manpower. The processor includes a rotor which can hold numerous cartridges containing inert or adsorbent material for holding samples, and a pair of stators on opposite sides of the rotor. The stators form stations spaced along the path of the cartridges which lie in the rotor, and each station can include an aperture in one stator through which a fluid can be applied to a cartridge resting at that station, and an aperture in the other stator which can receive the fluid which has passed through the cartridge. The stators are sealed to the ends of the cartridges lying on the rotor, to thereby isolate the stations from one another.

  17. Urban air quality assessment using monitoring data of fractionized aerosol samples, chemometrics and meteorological conditions.

    PubMed

    Yotova, Galina I; Tsitouridou, Roxani; Tsakovski, Stefan L; Simeonov, Vasil D

    2016-01-01

    The present article deals with assessment of urban air by using monitoring data for 10 different aerosol fractions (0.015-16 μm) collected at a typical urban site in City of Thessaloniki, Greece. The data set was subject to multivariate statistical analysis (cluster analysis and principal components analysis) and, additionally, to HYSPLIT back trajectory modeling in order to assess in a better way the impact of the weather conditions on the pollution sources identified. A specific element of the study is the effort to clarify the role of outliers in the data set. The reason for the appearance of outliers is strongly related to the atmospheric condition on the particular sampling days leading to enhanced concentration of pollutants (secondary emissions, sea sprays, road and soil dust, combustion processes) especially for ultra fine and coarse particles. It is also shown that three major sources affect the urban air quality of the location studied-sea sprays, mineral dust and anthropogenic influences (agricultural activity, combustion processes, and industrial sources). The level of impact is related to certain extent to the aerosol fraction size. The assessment of the meteorological conditions leads to defining of four downwind patterns affecting the air quality (Pelagic, Western and Central Europe, Eastern and Northeastern Europe and Africa and Southern Europe). Thus, the present study offers a complete urban air assessment taking into account the weather conditions, pollution sources and aerosol fractioning. PMID:26942452

  18. Breakthrough of 1,3-dichloropropene and chloropicrin from 600 mg XAD-4 air sampling tubes

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Accurately measuring air concentrations of agricultural fumigants is important for the regulation of air quality. Understanding the conditions under which sorbent tubes can effectively retain such fumigants during sampling is critical in mitigating chemical breakthrough from the tubes and facilitati...

  19. Tank 12H residuals sample analysis report

    SciTech Connect

    Oji, L. N.; Shine, E. P.; Diprete, D. P.; Coleman, C. J.; Hay, M. S.

    2015-06-11

    The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 12H final characterization samples to determine the residual tank inventory prior to grouting. Eleven Tank 12H floor and mound residual material samples and three cooling coil scrape samples were collected and delivered to SRNL between May and August of 2014.

  20. Systemic Analysis Approaches for Air Transportation

    NASA Technical Reports Server (NTRS)

    Conway, Sheila

    2005-01-01

    Air transportation system designers have had only limited success using traditional operations research and parametric modeling approaches in their analyses of innovations. They need a systemic methodology for modeling of safety-critical infrastructure that is comprehensive, objective, and sufficiently concrete, yet simple enough to be used with reasonable investment. The methodology must also be amenable to quantitative analysis so issues of system safety and stability can be rigorously addressed. However, air transportation has proven itself an extensive, complex system whose behavior is difficult to describe, no less predict. There is a wide range of system analysis techniques available, but some are more appropriate for certain applications than others. Specifically in the area of complex system analysis, the literature suggests that both agent-based models and network analysis techniques may be useful. This paper discusses the theoretical basis for each approach in these applications, and explores their historic and potential further use for air transportation analysis.

  1. MGA Analysis on Elevated 238 Pu Samples

    NASA Astrophysics Data System (ADS)

    Wang, T. F.; Moody, K. J.; Raschke, K. E.; Ruhter, W. D.

    2002-10-01

    Plutonium gamma-ray data analysis, in the 100-keV region, using MGA has been improved to overcome the original maximum limit of 2% 238Pu relative plutonium content in a sample in order to perform an analysis. MGA analysis results of elevated 238Pu samples are compared to the results from mass spectrometry.

  2. REPRESENTATIVE SAMPLING AND ANALYSIS OF HETEROGENEOUS SOILS

    EPA Science Inventory

    Standard sampling and analysis methods for hazardous substances in contaminated soils currently are available and routinely employed. Standard methods inherently assume a homogeneous soil matrix and contaminant distribution; therefore only small sample quantities typically are p...

  3. SAMPLING AND ANALYSIS OF ATMOSPHERIC AEROSOLS

    EPA Science Inventory

    Sampling and analysis requirements for the characterization of ambient particles are reviewed. The choice of sampling equipment and characterization procedures for ambient particles are often dictated by the objectives of the experiment. The paper describes the procedures and the...

  4. Diffusive sampling and measurement of microbial volatile organic compounds in indoor air.

    PubMed

    Araki, A; Eitaki, Y; Kawai, T; Kanazawa, A; Takeda, M; Kishi, R

    2009-10-01

    Microbial volatile organic compounds (MVOC), chemicals emitted from various microorganisms, in indoor air have been of concern in recent years. For large field studies, diffusive samplers are widely used to measure indoor environments. Since the sampling rate of a sampler is a fundamental parameter to calculate concentration, the sampling rates of eight MVOC with diffusive samplers were determined experimentally using a newly developed water-bubbling method: air was supplied to the MVOC-solutions and the vapor collected in an exposure bag, where diffusive and active samplers were placed in parallel for comparison. Correlations between the diffusive and active samplings gave good linear regressions. The sampling rates were 30-35 ml/min and the detection limits were 0.044-0.178 microg/m(3), as determined by GC/MS analysis. Application of the sampling rates in indoor air was validated by parallel sampling of the diffusive and active sampling method. 5% Propan-2-ol/CS(2) was the best solvent to desorb the compounds from absorbents. The procedure was applied to a field study in 41 dwellings. The most frequently detected compounds were hexan-2-one and heptan-2-one, with 97.5% detection rates and geometric mean values of 0.470 and 0.302 microg/m(3), respectively. This study shows that diffusive samplers are applicable to measure indoor MVOC levels. Practical Implications At present, there are still limited reports on indoor Microbial Volatile Organic Compounds (MVOC) levels in general dwellings and occupants' health. Compared with active sampling methods, air sampling using a diffusive sampler is particularly advantageous for use in large field studies due to its smallness, light-size, easy-handling, and cost-effectiveness. In this study, sampling rates of selected MVOC of the diffusive sampler were determined using the water-bubbling method: generating gases by water-bubbling and exposing the diffusive and active samplers at the same time. The obtained sampling rates

  5. PIXE analysis of Nigerian flour and bread samples

    NASA Astrophysics Data System (ADS)

    Olise, Felix S.; Fernandes, Adriana M.; Cristina Chaves, P.; Taborda, Ana; Reis, Miguel A.

    2014-01-01

    The alleged use of potassium bromate (KBrO3) in bread baking led a few authors to report on the chemical methods for the determination of KBrO3 levels in bread. In order to examine the potentials of a non chemical particle induced X-ray emission (PIXE) method for this purpose, six sets of samples, each composed of flour, dough and bread from a production batch were analysed. The samples were obtained from six different bakers of bread at Ile-Ife, Nigeria. The flour samples were air-dried while others were freeze dried at about -16 °C. The samples were homogenised in an agate mortar and then pelletised. Samples were analysed at the CTN standard PIXE setup and standard procedures for thick target samples analysis were followed. In some samples significant concentrations of bromine were found. In the present work we present possible explanations for the presence of this potentially dangerous contaminant in the samples.

  6. PCB Analysis Plan for Tank Archive Samples

    SciTech Connect

    NGUYEN, D.M.

    2001-03-22

    This analysis plan specifies laboratory analysis, quality assurance/quality control (QA/QC), and data reporting requirements for analyzing polychlorinated biphenyls (PCB) concentrations in archive samples. Tank waste archive samples that are planned for PCB analysis are identified in Nguyen 2001. The tanks and samples are summarized in Table 1-1. The analytical data will be used to establish a PCB baseline inventory in Hanford tanks.

  7. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  8. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  9. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Approved sampling devices; operation; air... DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  10. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  11. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  12. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  13. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  14. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Approved sampling devices; operation; air... DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  15. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  16. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  17. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  18. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  19. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Approved sampling devices; operation; air... DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  20. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  1. GIS implementation in air pollution analysis

    SciTech Connect

    Chaaban, F.G.

    1998-07-01

    Air quality modeling and simulation is an indispensable tool used in different environmental studies that attempt to estimate air pollution levels caused by existing or planned combustion processes, to evaluate proposed emission reduction technologies, to select sites for new emission sources, and accordingly to establish emission control strategies in different energy conversion sectors. Modeling techniques, based on established mathematical formulation, are widely used for simulating air pollution caused mainly by the transportation and electric power sectors. Geographic information systems, GIS, link spatial information to alphanumeric information thus developing geographically referenced database. GIS systems have already been incorporated successfully into several fields in the energy sector and are proven to be a very efficient and robust tool for relevant analysis. In the environmental studies, GIS can answer many questions related to air pollution such as pollution sources as well as identification of regions in which the concentration may exceed limits set by local and international standards. The work presented in this paper is aimed at integrating GIS into air pollution analysis. The main objective is to estimate, using advanced graphical illustrations, the concentration levels of different types of air effluents emitted from point, line, or area sources. The integrated package is then used to examine the influence of various mitigation strategies on the air pollutants levels, and hence to evaluate the effectiveness of these strategies. The paper is concluded by case studies from the transportation and power sectors.

  2. Ultrasonic extraction and field-portable anodic stripping voltammetry for the determination of lead in workplace air samples.

    PubMed

    Ashley, K; Mapp, K J; Millson, M

    1998-10-01

    An on-site, field-portable analytical method for the determination of lead in workplace air samples, based on the use of ultrasonic extraction and anodic stripping voltammetry (ASV), was evaluated. Workplace air samples were obtained using a standard method involving particulate collection onto mixed cellulose ester membrane filters. Samples were collected at work sites where airborne particulates were generated from the abrasive blasting of lead-containing paint on highway bridges. Ultrasonic extraction (UE) of air filter samples in diluted nitric acid, followed by portable ASV, was used for the determination of lead. Also, performance evaluation samples consisting of reference materials of known lead concentration were subjected to the UE-ASV procedure for lead determination. Confirmatory analyses of the air filters and performance evaluation samples subjected to the UE-ASV lead measurement method were conducted by hotplate digestion in concentrated nitric acid and 30% hydrogen peroxide, followed by inductively coupled plasma-atomic emission spectrometric (ICP-AES) determination of lead. Recoveries of lead from performance evaluation materials (when using the UE-ASV method) were found to be quantitative. The performance of the UE-ASV method for lead in air filters was found to be acceptable, as evaluated by comparison with results from hotplate strong acid digestion followed by ICP-AES analysis. Based on the results of this study, the ultrasonic extraction/portable ASV procedure demonstrates potential for the on-site determination of lead in personal breathing zone and area air samples. PMID:9794065

  3. Thermal analysis of car air conditioning

    NASA Astrophysics Data System (ADS)

    Trzebiński, Daniel; Szczygieł, Ireneusz

    2010-10-01

    Thermodynamic analysis of car air cooler is presented in this paper. Typical refrigerator cycles are studied. The first: with uncontrolled orifice and non controlled compressor and the second one with the thermostatic controlled expansion valve and externally controlled compressor. The influence of the refrigerant decrease and the change of the air temperature which gets to exchangers on the refrigeration efficiency of the system; was analysed. Also, its effectiveness and the power required to drive the compressor were investigated. The impact of improper refrigerant charge on the performance of air conditioning systems was also checked.

  4. Review of Various Air Sampling Methods for Solvent Vapors.

    ERIC Educational Resources Information Center

    Maykoski, R. T.

    Vapors of trichloroethylene, toluene, methyl ethyl ketone, and butyl cellosolve in air were collected using Scotchpac and Tedlar bags, glass prescription bottles, and charcoal adsorption tubes. Efficiencies of collection are reported. (Author/RH)

  5. Microbial Air and Surface Monitoring Results from International Space Station Samples

    NASA Technical Reports Server (NTRS)

    Ott, C. Mark; Bruce, Rebekah J.; Castro, Victoria A.; Novikova, Natalia D.; Pierson, D. L.

    2005-01-01

    Over the course of long-duration spaceflight, spacecraft develop a microbial ecology that directly interacts with the crew of the vehicle. While most microorganisms are harmless or beneficial to the inhabitants of the vehicle, the presence of medically significant organisms appearing in this semi-closed environment could adversely affect crew health and performance. The risk of exposure of the crew to medically significant organisms during a mission is estimated using information gathered during nominal and contingency environmental monitoring. Analysis of the air and surface microbiota in the habitable compartments of the International Space Station (ISS) over the last four years indicate a high presence of Staphylococcus species reflecting the human inhabitants of the vehicle. Generally, air and surface microbial concentrations are below system design specifications, suggesting a lower risk of contact infection or biodegradation. An evaluation of sample frequency indicates a decrease in the identification of new species, suggesting a lower potential for unknown microorganisms to be identified. However, the opportunistic pathogen, Staphylococcus aureus, has been identified in 3 of the last 5 air samples and 5 of the last 9 surface samples. In addition, 47% of the coagulase negative Staphylococcus species that were isolated from the crew, ISS, and its hardware were found to be methicillin resistance. In combination, these observations suggest the potential of methicillin resistant infectious agents over time.

  6. Application of a dry-gas meter for measuring air sample volumes in an ambient air monitoring network

    SciTech Connect

    Fritz, Brad G.

    2009-05-24

    Ambient air monitoring for non-research applications (e.g. compliance) occurs at locations throughout the world. Often, the air sampling systems employed for these purposes employee simple yet robust equipment capable of handling the rigors of demanding sampling schedules. At the Hanford Site (near Richland, Washington) concentrations of radionuclides in ambient air are monitored continuously at 44 locations. In 2004, mechanical dry-gas meters were incorporated into the Hanford Site ambient air sample collection system to allow the direct measurement of sample volumes. These meters replaced a portable airflow measurement system that required two manual flow measurements and a sample duration measurement to determine sample volume. A six-month evaluation of the dry-gas meters compared sample volumes calculated using the original flow rate method to the direct sample volume measurement (new method). The results of the evaluation indicate that use of the dry-gas meters result in accurate sample volume measurements and provide greater confidence in the measured sample volumes. In several years of in-network use, the meters have proven to be reliable and have resulted in an improved sampling system.

  7. DWPF GC FILTER ASSEMBLY SAMPLING AND ANALYSIS

    SciTech Connect

    Bannochie, C.; Imrich, K.

    2009-11-11

    On March 18, 2009 a Defense Waste Processing Facility (DWPF) GC Line Filter Assembly was received at the Savannah River National Laboratory (SRNL). This filter assembly was removed from operation following the completion of Sludge Batch 4 processing in the DWPF. Work on this sample was requested in a Technical Assistance Request. This document reports the pictures, observations, samples collected, and analytical results for the assembly. The assembly arrived at SRNL separated into its three component filters: high efficiency particulate air (HEPA)-1, HEPA-2, and a high efficiency mist evaporator (HEME). Each stage of the assembly's media was sampled and examined visually and by scanning electron microscopy (SEM). Solids built up in the filter housing following the first stage HEME, were dissolved in dilute nitric acid and analyzed by ICP-AES and the undissolved white solids were analyzed by x-ray diffraction (XRD). The vast majority of the material in each of the three stages of the DWPF GC Line Filter Assembly appears to be contaminated with a Hg compound that is {approx}59 wt% Hg on a total solids basis. The Hg species was identified by XRD analysis to contain a mixture of Hg{sub 4}(OH)(NO{sub 3}){sub 3} and Hg{sub 10}(OH){sub 4}(NO{sub 3}){sub 6}. Only in the core sample of the second stage HEPA, did this material appear to be completely covering portions of the filter media, possibly explaining the pressure drops observed by DWPF. The fact that the material migrates through the HEME filter and both HEPA filters, and that it was seen collecting on the outlet side of the HEME filter, would seem to indicate that these filters are not efficient at removing this material. Further SRAT off-gas system modeling should help determine the extent of Hg breakthrough past the Mercury Water Wash Tank (MWWT). The SRAT off-gas system has not been modeled since startup of the facility. Improvements to the efficiency of Hg stripping prior to the ammonia scrubber would seem to be

  8. Vapor sampling and analysis plan. Revision 1

    SciTech Connect

    Homi, C.S.

    1995-10-10

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from both SST and DST tanks

  9. Atmospheric trace gas measurements with a new clean air sampling system

    SciTech Connect

    Leifer, R.; Sommers, K.; Guggenheim, S.F.

    1981-10-01

    The development of a new clean air sampling system for the Department of Energy's WB-57F aircraft has allowed the analysis of CCl/sub 3/F (Fluorocarbon-11), CCl/sub 2/F/sub 2/ (Fluorocarbon-12), CHClF/sub 2/ (Fluorocarbon-22), C/sub 2/Cl/sub 3/F/sub 3/ (Fluorocarbon-113), CH/sub 4/, CO, CO/sub 2/, N/sub 2/O, CH/sub 3/Cl, CCl/sub 4/, CH/sub 3/CCl/sub 3/, OCS and SF/sub 6/ in tropospheric and stratospheric samples. Samples collected during the interception of the plume from the eruption of Mount St. Helens indicate that OCS was injected into the stratosphere during the eruption. A large CO/sub 2/ gradient was found at 19.2 km on this flight.

  10. Low-cost monitoring of Campylobacter in poultry houses by air sampling and quantitative PCR.

    PubMed

    Søndergaard, M S R; Josefsen, M H; Löfström, C; Christensen, L S; Wieczorek, K; Osek, J; Hoorfar, J

    2014-02-01

    The present study describes the evaluation of a method for the quantification of Campylobacter by air sampling in poultry houses. Sampling was carried out in conventional chicken houses in Poland, in addition to a preliminary sampling in Denmark. Each measurement consisted of three air samples, two standard boot swab fecal samples, and one airborne particle count. Sampling was conducted over an 8-week period in three flocks, assessing the presence and levels of Campylobacter in boot swabs and air samples using quantitative real-time PCR. The detection limit for air sampling was approximately 100 Campylobacter cell equivalents (CCE)/m3. Airborne particle counts were used to analyze the size distribution of airborne particles (0.3 to 10 μm) in the chicken houses in relation to the level of airborne Campylobacter. No correlation was found. Using air sampling, Campylobacter was detected in the flocks right away, while boot swab samples were positive after 2 weeks. All samples collected were positive for Campylobacter from week 2 through the rest of the rearing period for both sampling techniques, although levels 1- to 2-log CCE higher were found with air sampling. At week 8, the levels were approximately 10(4) and 10(5) CCE per sample for boot swabs and air, respectively. In conclusion, using air samples combined with quantitative real-time PCR, Campylobacter contamination could be detected earlier than by boot swabs and was found to be a more convenient technique for monitoring and/or to obtain enumeration data useful for quantitative risk assessment of Campylobacter. PMID:24490929

  11. Statistical Analysis Techniques for Small Sample Sizes

    NASA Technical Reports Server (NTRS)

    Navard, S. E.

    1984-01-01

    The small sample sizes problem which is encountered when dealing with analysis of space-flight data is examined. Because of such a amount of data available, careful analyses are essential to extract the maximum amount of information with acceptable accuracy. Statistical analysis of small samples is described. The background material necessary for understanding statistical hypothesis testing is outlined and the various tests which can be done on small samples are explained. Emphasis is on the underlying assumptions of each test and on considerations needed to choose the most appropriate test for a given type of analysis.

  12. Field test of a generic method for the sampling and analysis of halogenated hydrocarbons listed in title III of the Clean Air Act amendments of 1990. Report for January 1992-December 1993

    SciTech Connect

    McGaughey, J.F.; Bursey, J.T.; Rice, J.; Merrill, R.G.; Jackson, M.D.

    1993-01-01

    To validate a new source test method for EPA use, the performance of the sampling and analytical methodology for the chemicals of interest must be established and demonstrated through field tests at sources similar to those of interest. Validation studies for measuring volatile and semi-volatile halogenated organics were undertaken in two different studies. Repeated sampling runs of the Volatile Organic Sample Train (VOST; SW-846 Sampling Method 0030 with Analytical Method 5041) and Semi-Volatile Organic Sample Train (Semi-VOST; SW-846 Method 0010 with Analytical Method 8270) were collected at two source locations. Quadruple sampling trains were used in each run, with two of the trains being spiked with standards. For the VOST method, the results of the two field studies were consistent with laboratory tests. For the Semi-VOST method, consistent results were obtained in the laboratory study and one of the field tests. At the second field site, the Semi-VOST data were inadequate because of problems encountered in preparation of the samples for analysis.

  13. Analysis of enantiomeric and non-enantiomeric monoterpenes in plant emissions using portable dynamic air sampling/solid-phase microextraction (PDAS-SPME) and chiral gas chromatography/mass spectrometry

    NASA Astrophysics Data System (ADS)

    Yassaa, Noureddine; Williams, Jonathan

    A portable dynamic air sampler (PDAS) using a porous polymer solid-phase microextraction (SPME) fibre has been validated for the determination of biogenic enantiomeric and non-enantiomeric monoterpenes in air. These compounds were adsorbed in the field, and then thermally desorbed at 250 °C in a gas chromatograph injector port connected via a β-cyclodextrin capillary separating column to a mass spectrometer. The optimized method has been applied for investigating the emissions of enantiomeric monoterpenes from Pseudotsuga menziesii (Douglas-fir), Rosmarinus officinalis (Rosemary) and Lavandula lanata (Lavender) which were selected as representative of coniferous trees and aromatic plants, respectively. The enantiomers of α-pinene, sabinene, camphene, δ-3-carene, β-pinene, limonene, β-phellandrene, 4-carene and camphor were successfully determined in the emissions from the three plants. While Douglas-fir showed a strong predominance toward (-)-enantiomers, Rosemary and Lavender demonstrated a large variation in enantiomeric distribution of monoterpenes. The simplicity, rapidity and sensitivity of dynamic sampling with porous polymer coated SPME fibres coupled to chiral capillary gas chromatography/mass spectrometry (GC/MS) makes this method potentially useful for in-field investigations of atmosphere-biosphere interactions and studies of optically explicit atmospheric chemistry.

  14. An analysis of air-turborocket performance

    NASA Astrophysics Data System (ADS)

    Bussi, Giuseppe; Colasurdo, Guido; Pastrone, Dario

    1993-06-01

    In order to assess the capabilities of the air-turborocket, an off-design analysis of a representative LOX-LH2 fed engine is carried out. Working lines on an envisageable compressor map are drawn for different flight conditions along a typical transatmospheric vehicle flight path. Characteristic aspects of the air-turborocket behavior in the spontaneous and controlled mode are highlighted. Specific thrust and propellant consumption at full throttle are computed, both in the dry and augmented mode. Performance achievable by exploiting the permissible mass flow range of the compressor map via the variation of the nozzle throat area, is shown.

  15. Riverland ERA cleanup sampling and analysis plan

    SciTech Connect

    Heiden, C.E.

    1993-07-01

    This report describes the Riverland Expedited Response Action taking place at the Hanford Reservation. Characterization of potential waste sites within the Riverland ERA boundaries was conducted in October and November 1992. This sampling and analysis plan contains two parts: The field sampling plan (Part 1) and the quality assurance project plan (Part 2). The field sampling plan describes the activities to be performed, defines sample designation, and identifies sample analysis to be performed. The quality assurance project plan establishes data quality objectives, defines analytical methods and procedures and documentation requirements, and provides established technical procedures to be used for field sampling and measurement. The quality assurance project plan details all quality assurance/quality control procedures to be followed to ensure that usable and defensible data are collected.

  16. Systems and methods for sample analysis

    SciTech Connect

    Cooks, Robert Graham; Li, Guangtao; Li, Xin; Ouyang, Zheng

    2015-01-13

    The invention generally relates to systems and methods for sample analysis. In certain embodiments, the invention provides a system for analyzing a sample that includes a probe including a material connected to a high voltage source, a device for generating a heated gas, and a mass analyzer.

  17. Systems and methods for sample analysis

    SciTech Connect

    Cooks, Robert Graham; Li, Guangtao; Li, Xin; Ouyang, Zheng

    2015-10-20

    The invention generally relates to systems and methods for sample analysis. In certain embodiments, the invention provides a system for analyzing a sample that includes a probe including a material connected to a high voltage source, a device for generating a heated gas, and a mass analyzer.

  18. Comparison of stationary and personal air sampling with an air dispersion model for children's ambient exposure to manganese.

    PubMed

    Fulk, Florence; Haynes, Erin N; Hilbert, Timothy J; Brown, David; Petersen, Dan; Reponen, Tiina

    2016-09-01

    Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to assess exposure for children enrolled in the Communities Actively Researching Exposure Study in Marietta, OH. Ambient air Mn concentration values were modeled using US Environmental Protection Agency's Air Dispersion Model AERMOD based on emissions from the ferromanganese refinery located in Marietta. Modeled Mn concentrations were compared with Mn concentrations from a nearby stationary air monitor. The Index of Agreement for modeled versus monitored data was 0.34 (48 h levels) and 0.79 (monthly levels). Fractional bias was 0.026 for 48 h levels and -0.019 for monthly levels. The ratio of modeled ambient air Mn to measured ambient air Mn at the annual time scale was 0.94. Modeled values were also time matched to personal air samples for 19 children. The modeled values explained a greater degree of variability in personal exposures compared with time-weighted distance from the emission source. Based on these results modeled Mn concentrations provided a suitable approach for assessing airborne Mn exposure in this cohort. PMID:27168393

  19. Detection of the Urban Release of a Bacillus anthracis Simulant by Air Sampling

    PubMed Central

    Garza, Alexander G.; Van Cuyk, Sheila M.; Brown, Michael J.

    2014-01-01

    In 2005 and 2009, the Pentagon Force Protection Agency (PFPA) staged deliberate releases of a commercially available organic pesticide containing Bacillus amyloliquefaciens to evaluate PFPA's biothreat response protocols. In concert with, but independent of, these releases, the Department of Homeland Security sponsored experiments to evaluate the efficacy of commonly employed air and surface sampling techniques for detection of an aerosolized biological agent. High-volume air samplers were placed in the expected downwind plume, and samples were collected before, during, and after the releases. Environmental surface and personal air samples were collected in the vicinity of the high-volume air samplers hours after the plume had dispersed. The results indicate it is feasible to detect the release of a biological agent in an urban area both during and after the release of a biological agent using high-volume air and environmental sampling techniques. PMID:24697146

  20. Detection of the urban release of a bacillus anthracis simulant by air sampling.

    PubMed

    Garza, Alexander G; Van Cuyk, Sheila M; Brown, Michael J; Omberg, Kristin M

    2014-01-01

    In 2005 and 2009, the Pentagon Force Protection Agency (PFPA) staged deliberate releases of a commercially available organic pesticide containing Bacillus amyloliquefaciens to evaluate PFPA's biothreat response protocols. In concert with, but independent of, these releases, the Department of Homeland Security sponsored experiments to evaluate the efficacy of commonly employed air and surface sampling techniques for detection of an aerosolized biological agent. High-volume air samplers were placed in the expected downwind plume, and samples were collected before, during, and after the releases. Environmental surface and personal air samples were collected in the vicinity of the high-volume air samplers hours after the plume had dispersed. The results indicate it is feasible to detect the release of a biological agent in an urban area both during and after the release of a biological agent using high-volume air and environmental sampling techniques. PMID:24697146

  1. Review of the Physical Science Facility Stack Air Sampling Probe Locations

    SciTech Connect

    Glissmeyer, John A.

    2007-09-30

    This letter report reviews compliance of the current design of the Physical Science Facility (PSF) stack air sampling locations with the ANSI/HPS N13.1-1999 standard. The review was based on performance criteria used for locating air sampling probes, the design documents provided and available information on systems previously tested for compliance with the criteria. Recommendations are presented for ways to bring the design into compliance with the requirements for the sampling probe placement.

  2. Development and validation by accuracy profile of a method for the analysis of monoterpenes in indoor air by active sampling and thermal desorption-gas chromatography-mass spectrometry.

    PubMed

    Marlet, Christelle; Lognay, Georges

    2010-09-15

    The technique of thermal desorption (TD)-GC/MS was evaluated for the measurement of monoterpenes in indoor air. The validation strategy was intentionally oriented towards routine use and the reliability of the method rather than extreme performance. For this reason, validation by accuracy profile was chosen. The accuracy profile procedure, which is based on the concept of total error (bias+standard deviation), guarantees that a known proportion of future results obtained with the method will be within acceptance limits. For all the compounds tested in the present study, alpha-pinene, alpha-terpineol, beta-pinene, d-limonene, Delta(3)-carene, camphene, 1,8-cineole, p-cymene, linalool, but not in the case of carvone, the accuracy profile procedure established that at least 95% of the future results obtained would be within the +/-15% acceptance limits of the validated method over the whole defined concentration range. Other parameters, such as selectivity, recovery, repeatability, stability of the molecules of interest and the effect of temperature, were also determined. The performance of the described method was finally evaluated by the analysis of indoor air from new timber frame constructions. PMID:20801323

  3. Longitudinal Metagenomic Analysis of Hospital Air Identifies Clinically Relevant Microbes

    PubMed Central

    King, Paula; Pham, Long K.; Waltz, Shannon; Sphar, Dan; Yamamoto, Robert T.; Conrad, Douglas; Taplitz, Randy; Torriani, Francesca

    2016-01-01

    We describe the sampling of sixty-three uncultured hospital air samples collected over a six-month period and analysis using shotgun metagenomic sequencing. Our primary goals were to determine the longitudinal metagenomic variability of this environment, identify and characterize genomes of potential pathogens and determine whether they are atypical to the hospital airborne metagenome. Air samples were collected from eight locations which included patient wards, the main lobby and outside. The resulting DNA libraries produced 972 million sequences representing 51 gigabases. Hierarchical clustering of samples by the most abundant 50 microbial orders generated three major nodes which primarily clustered by type of location. Because the indoor locations were longitudinally consistent, episodic relative increases in microbial genomic signatures related to the opportunistic pathogens Aspergillus, Penicillium and Stenotrophomonas were identified as outliers at specific locations. Further analysis of microbial reads specific for Stenotrophomonas maltophilia indicated homology to a sequenced multi-drug resistant clinical strain and we observed broad sequence coverage of resistance genes. We demonstrate that a shotgun metagenomic sequencing approach can be used to characterize the resistance determinants of pathogen genomes that are uncharacteristic for an otherwise consistent hospital air microbial metagenomic profile. PMID:27482891

  4. Fluidics platform and method for sample preparation and analysis

    SciTech Connect

    Benner, W. Henry; Dzenitis, John M.; Bennet, William J.; Baker, Brian R.

    2014-08-19

    Herein provided are fluidics platform and method for sample preparation and analysis. The fluidics platform is capable of analyzing DNA from blood samples using amplification assays such as polymerase-chain-reaction assays and loop-mediated-isothermal-amplification assays. The fluidics platform can also be used for other types of assays and analyzes. In some embodiments, a sample in a sealed tube can be inserted directly. The following isolation, detection, and analyzes can be performed without a user's intervention. The disclosed platform may also comprises a sample preparation system with a magnetic actuator, a heater, and an air-drying mechanism, and fluid manipulation processes for extraction, washing, elution, assay assembly, assay detection, and cleaning after reactions and between samples.

  5. Electron spectroscopy for chemical analysis: Sample analysis

    NASA Technical Reports Server (NTRS)

    Carter, W. B.

    1989-01-01

    Exposure conditions in atomic oxygen (ESCA) was performed on an SSL-100/206 Small Spot Spectrometer. All data were taken with the use of a low voltage electron flood gun and a charge neutralization screen to minimize charging effects on the data. The X-ray spot size and electron flood gun voltage used are recorded on the individual spectra as are the instrumental resolutions. Two types of spectra were obtained for each specimen: (1) general surveys, and (2) high resolution spectra. The two types of data reduction performed are: (1) semiquantitative compositional analysis, and (2) peak fitting. The materials analyzed are: (1) kapton 4, 5, and 6, (2) HDPE 19, 20, and 21, and (3) PVDF 4, 5, and 6.

  6. POTW sludge sampling and analysis guidance document

    SciTech Connect

    Not Available

    1989-08-01

    In view of the variability of municipal sludge quality, appropriate procedures must be followed to collect and analyze samples that accurately represent each POTW's sludge quality. The manual was developed to provide that guidance to POTW operators, engineers, managers, chemists and permit writers. It was intended to provide guidance in developing and implementing a sampling and analysis program, to gather information on sludge quality and determine compliance with permit conditions. The manual is based on current, state-of-the-art field and laboratory practices and therefore is recommended for all sludge sampling and analysis programs.

  7. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    SciTech Connect

    Barnett, J. Matthew; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-02-17

    Since the mid-1980s, Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as the correction factor for self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. This value accounts for activity that cannot be detected by direct counting of alpha and beta particles. Emissions can be degraded or blocked by filter fibers for particles buried in the filter material or by inactive dust particles collected with the radioactive particles. These filters are used for monitoring air emissions from PNNL stacks for radioactive particles. This paper describes an effort to re-evaluate self-absorption effects in particulate radioactive air sample filters (Versapor® 3000, 47 mm diameter) used at PNNL. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Filter ratios were calculated by dividing the initial counts by the post-digestion counts with the expectation that post-digestion counts would be higher because digestion would expose radioactivity embedded in the filter in addition to that on top of the filter. Contrary to expectations, the post digestion readings were almost always lower than initial readings and averaged approximately half the initial readings for both alpha and beta activity. Before and after digestion readings appeared to be related to each other, but with a low coefficient of determination (R^2) value. The ratios had a wide range of values indicating that this method did not provide sufficient precision to quantify self

  8. METHODS TO SAMPLE AIR BORNE PROPAGULES OF ASPERGILLUS FLAVUS

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Several techniques (cyclone samplers, filter samplers and rotorods) were evaluated for detection of airborne Aspergillus flavus Link propagules in a cultivated region of southwest Arizona. Cyclone samplers operated continuously for 168 h (7 d) collected a dry sample that was ideal for quantificatio...

  9. Analysis procedure for americium in environmental samples

    SciTech Connect

    Holloway, R.W.; Hayes, D.W.

    1982-01-01

    Several methods for the analysis of /sup 241/Am in environmental samples were evaluated and a preferred method was selected. This method was modified and used to determine the /sup 241/Am content in sediments, biota, and water. The advantages and limitations of the method are discussed. The method is also suitable for /sup 244/Cm analysis.

  10. Study of PCBs and PBDEs in King George Island, Antarctica, using PUF passive air sampling

    NASA Astrophysics Data System (ADS)

    Li, Yingming; Geng, Dawei; Liu, Fubin; Wang, Thanh; Wang, Pu; Zhang, Qinghua; Jiang, Guibin

    2012-05-01

    Polyurethane foam (PUF)-disk based passive air samplers were deployed in King George Island, Antarctica, during the austral summer of 2009-2010, to investigate levels, distributions and potential sources of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in Antarctic air. The atmospheric levels of ∑ indicator PCBs and ∑14 PBDEs ranged from 1.66 to 6.50 pg m-3 and from 0.67 to 2.98 pg m-3, respectively. PCBs homologue profiles were dominated by di-PCBs, tri-PCBs and tetra-PCBs, whereas BDE-17 and BDE-28 were the predominant congeners of PBDEs, which could be explained by long-range atmospheric transport processes. However, the sampling sites close to the Antarctic research stations showed higher atmospheric concentrations of PCBs and PBDEs than the other sites, reflecting potential local sources from the Antarctic research stations. The non-Aroclor congener PCB-11 was found in all the air samples, with air concentrations of 3.60-31.4 pg m-3 (average 15.2 pg m-3). Comparison between the results derived from PUF-disk passive air sampling and high-volume air sampling validates the feasibility of using the passive air samplers in Antarctic air. To our knowledge, this study is the first employment of PUF-disk based passive air samplers in Antarctic atmosphere.

  11. Optimisation steps of an innovative air sampling method for semi volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Lazarov, Borislav; Swinnen, Rudi; Spruyt, Maarten; Goelen, Eddy; Stranger, Marianne; Desmet, Gilbert; Wauters, Eric

    2013-11-01

    This work describes optimisation steps of an innovative method for the measurement several groups of semi-volatile organic compounds (SVOCs) in air, collecting both gaseous and particulate air fractions. It is based on active air sampling on sorption tubes (consisting of polydimethylsiloxane (PDMS) and Tenax TA), followed by thermal desorption and gas chromatography mass spectrometry analysis (TD-GC-MS). The optimised method was validated in the laboratory for the measurement of selected target compounds from the following chemical classes: polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and phthalate esters (PEs). It was applied in different Belgian urban outdoor as well as indoor environments. The new method is characterised by limits of detection in the range of 0.003-0.3 ng m-3 for PAHs, 0.004-0.2 ng m-3 for PCBs, 0.113-0.201 ng m-3 for PBDEs and 0.002-0.2 ng m-3 for PEs, a linearity of 0.996 and a repeatability of less than 10% for all studied compounds.

  12. Some improvements in air particulate matter analysis by INAA

    NASA Astrophysics Data System (ADS)

    Farinha, M. M.; Freitas, M. C.; Almeida, S. M.; Reis, M. A.

    2001-06-01

    At ITN, analysis of air particulate matter has been made since 1999, stimulated by a contract for air quality monitoring of an urban waste incinerator. Samples are analysed by Instrumental Neutron Activation Analysis (INAA) and Proton Induced X-ray Emission (PIXE). Heavy metals and other elements are determined. The procedures for filter analysis have recently been changed, leading to the present comparison between the old and the new procedures. For INAA, in this new procedure we look for the 336.2 keV gamma line of 115mIn in addition to the gamma-ray line of 527.9 keV used for the detection of 115Cd. Cd evaluations obtained by both gamma lines are compared and detection limits for Cd are presented. Preliminary results for Cd, As, Ni, and Hg are shown for a region in the north of Lisbon.

  13. Mixed species radioiodine air sampling readout and dose assessment system

    DOEpatents

    Distenfeld, Carl H.; Klemish, Jr., Joseph R.

    1978-01-01

    This invention provides a simple, reliable, inexpensive and portable means and method for determining the thyroid dose rate of mixed airborne species of solid and gaseous radioiodine without requiring highly skilled personnel, such as health physicists or electronics technicians. To this end, this invention provides a means and method for sampling a gas from a source of a mixed species of solid and gaseous radioiodine for collection of the mixed species and readout and assessment of the emissions therefrom by cylindrically, concentrically and annularly molding the respective species around a cylindrical passage for receiving a conventional probe-type Geiger-Mueller radiation detector.

  14. Analysis of accurate 13C and 18O isotope measurements of CO2 in CARIBIC aircraft air samples from the tropical troposphere, and the upper troposphere/lowermost stratosphere

    NASA Astrophysics Data System (ADS)

    Assonov, S. S.; Brenninkmeijer, C. A. M.; Schuck, T. J.; Taylor, P.

    2010-03-01

    The project CARIBIC (http://caribic-atmospheric.com) aims to study atmospheric chemistry and transport by regularly measuring many compounds in the free troposphere (FT) and the upper troposphere/lowermost stratosphere (UT/LMS) by using passenger aircraft. Here CO2 concentrations and highly accurate isotope results are presented in detail together with supporting trace gas data. 509 CARIBIC-2 samples (highest precision and accuracy δ13C(CO2) and δ18O(CO2) data) from June 2007 until March 2009, together with CARIBIC-1 samples (flights between November 1999 and April 2002, 350 samples in total, 270 for NH, mostly δ13C(CO2) data) give a fairly extensive, unique data set for the NH free troposphere and the UT/LMS region. To compare data from different years a de-trending is applied. In the UT/LMS region δ13C(CO2), δ18O(CO2) and CO2 are found to correlate well with stratospheric tracers, in particular N2O. These correlations are in good agreement with current understanding of stratospheric circulation. δ18O(CO2) appears to be a useful, hitherto unused, tracer of atmospheric transport in the UT/LMS region. By filtering out the LMS data (based on N2O distribution), the isotope variations for the free and upper troposphere are obtained. These show however little latitudinal gradient, if any, and are in good agreement with the data of selected NOAA stations in NH tropics. Correlations between δ13C(CO2) and CO2 are observed both within single flight(s) covering long distances and for certain seasons. The overall variability in de-trended δ13C(CO2) and CO2 for CARIBIC-1 and CARIBIC-2 are similar and basically agree with each other, which also underscores the high quality of measurement. Based on all correlations, we discuss that CO2 distribution in the NH FT and UT (at CARIBIC flight routes) is regulated by uplift and pole-wards transport of tropical air up to approximately 50° N. The main reasons for

  15. Dispersion modeling of selected PAHs in urban air: A new approach combining dispersion model with GIS and passive air sampling

    NASA Astrophysics Data System (ADS)

    Sáňka, Ondřej; Melymuk, Lisa; Čupr, Pavel; Dvorská, Alice; Klánová, Jana

    2014-10-01

    This study introduces a new combined air concentration measurement and modeling approach that we propose can be useful in medium and long term air quality assessment. A dispersion study was carried out for four high molecular weight polycyclic aromatic hydrocarbons (PAHs) in an urban area with industrial, traffic and domestic heating sources. A geographic information system (GIS) was used both for processing of input data as well as visualization of the modeling results. The outcomes of the dispersion model were compared to the results of passive air sampling (PAS). Despite discrepancies between measured and modeled concentrations, an approach combining the two techniques is promising for future air quality assessment. Differences between measured and modeled concentrations, in particular when measured values exceed the modeled concentrations, are indicative of undocumented, sporadic pollutant sources. Thus, these differences can also be useful for assessing and refining emission inventories.

  16. Automated syringe sampler. [remote sampling of air and water

    NASA Technical Reports Server (NTRS)

    Purgold, G. C. (Inventor)

    1981-01-01

    A number of sampling services are disposed in a rack which slides into a housing. In response to a signal from an antenna, the circutry elements are activated which provide power individually, collectively, or selectively to a servomechanism thereby moving an actuator arm and the attached jawed bracket supporting an evaculated tube towards a stationary needle. One open end of the needle extends through the side wall of a conduit to the interior and the other open end is maintained within the protective sleeve, supported by a bifurcated bracket. A septum in punctured by the end of the needle within the sleeve and a sample of the fluid medium in the conduit flows through the needle and is transferred to a tube. The signal to the servo is then reversed and the actuator arm moves the tube back to its original position permitting the septum to expand and seal the hole made by the needle. The jawed bracket is attached by pivot to the actuator to facilitate tube replacement.

  17. Simultaneous analysis of organochlorine pesticides and polychlorinated biphenyls in air samples by using accelerated solvent extraction (ASE) and solid-phase micro-extraction (SPME) coupled to gas chromatography dual electron capture detection.

    PubMed

    Mokbel, Haifaa; Al Dine, Enaam Jamal; Elmoll, Ahmad; Liaud, Céline; Millet, Maurice

    2016-04-01

    An analytical method associating accelerated solvent extraction (ASE) and solid-phase micro-extraction (SPME) in immersion mode combined with gas chromatography dual electrons capture detectors (SPME-GC-2ECD) has been developed and studied for the simultaneous determination of 19 organochlorine pesticides (OCPs) and 22 polychlorinated biphenyls (PCBs) in air samples (active and XAD-2 passive samplers). Samples were extracted with ASE with acetonitrile using the following conditions: temperature, 150 °C; pressure, 1500 psi; static, 15 min; cycles, 3; purge, 300 s; flush, 100 %. Extracts were reduced to 1 mL, and 500 μL of this extract, filled with deionised water, was subject to SPME extraction. Experimental results indicated that the proposed method attained the best extraction efficiency under the optimised conditions: extraction of PCB-OCP mixture using 100-μm PDMS fibre at 80 °C for 40 min with no addition of salt. The performance of the proposed ASE-SPME-GC-2ECD methodology with respect to linearity, limit of quantification and detection was evaluated by spiking of XAD-2 resin with target compounds. The regression coefficient (R (2)) of most compounds was found to be high of 0.99. limits of detection (LODs) are between 0.02 and 4.90 ng m(-3), and limits of quantification (LOQs) are between 0.05 and 9.12 ng m(-3) and between 0.2 and 49 ng/sampler and 0.52 and 91 ng/sampler, respectively, for XAD-2 passive samplers. Finally, a developed procedure was applied to determine selected PCBs and OCPs in the atmosphere. PMID:26780048

  18. Joint Analysis of Multiple Metagenomic Samples

    PubMed Central

    Baran, Yael; Halperin, Eran

    2012-01-01

    The availability of metagenomic sequencing data, generated by sequencing DNA pooled from multiple microbes living jointly, has increased sharply in the last few years with developments in sequencing technology. Characterizing the contents of metagenomic samples is a challenging task, which has been extensively attempted by both supervised and unsupervised techniques, each with its own limitations. Common to practically all the methods is the processing of single samples only; when multiple samples are sequenced, each is analyzed separately and the results are combined. In this paper we propose to perform a combined analysis of a set of samples in order to obtain a better characterization of each of the samples, and provide two applications of this principle. First, we use an unsupervised probabilistic mixture model to infer hidden components shared across metagenomic samples. We incorporate the model in a novel framework for studying association of microbial sequence elements with phenotypes, analogous to the genome-wide association studies performed on human genomes: We demonstrate that stratification may result in false discoveries of such associations, and that the components inferred by the model can be used to correct for this stratification. Second, we propose a novel read clustering (also termed “binning”) algorithm which operates on multiple samples simultaneously, leveraging on the assumption that the different samples contain the same microbial species, possibly in different proportions. We show that integrating information across multiple samples yields more precise binning on each of the samples. Moreover, for both applications we demonstrate that given a fixed depth of coverage, the average per-sample performance generally increases with the number of sequenced samples as long as the per-sample coverage is high enough. PMID:22359490

  19. Salmonella recovery following air chilling for matched neck-skin and whole carcass sampling methodologies

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The prevalence and serogroups of Salmonella recovered following air chilling were determined for both enriched neck skin and matching enriched whole carcass samples. Commercially processed and eviscerated carcasses were air chilled to 4C before removing the neck skin (8.3 g) and stomaching in 83 mL...

  20. Trapping Efficiency of 1,3-Dichloropropene Isomers by XAD-4 Sorbent Tubes for Air Sampling

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Emission monitoring is necessary to evaluate the impact of air pollutants such as soil fumigants on the environment. Quantifying fumigant emissions often involves the use of air sampling tubes filled with sorbents to trap fumigants. 1,3-dichloropropene (1,3-D) and chloropicrin (CP) are being increas...

  1. Sampling and Analyzing Air Pollution: An Apparatus Suitable for Use in Schools.

    ERIC Educational Resources Information Center

    Rockwell, Dean M.; Hansen, Tony

    1994-01-01

    Describes two variations of an air sampler and analyzer that are inexpensive to construct, easy to operate, and designed to be used in an educational program. Variations use vacuum cleaners and aquarium pumps, and white facial tissues serve as filters. Samples of air pollution obtained by this method may be used from early grade school to advanced…

  2. Operational air sampling report. [Semiannual report], July 1--December 31, 1993

    SciTech Connect

    Lyons, C.L.

    1994-03-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 118 air samples collected in the only active tunnel complex, only one showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 206 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products.

  3. Operational air sampling report. [Semiannual report], January 1--June 30, 1993

    SciTech Connect

    Lyons, C.L.

    1993-12-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. This report discusses the REECo air sampling program which is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 243 air samples collected in the only active tunnel complex, none showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 246 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products.

  4. EVALUATION OF SAMPLING AND ANALYTICAL METHODOLOGY FOR POLYNUCLEAR AROMATIC COMPOUNDS IN INDOOR AIR

    EPA Science Inventory

    The objective of this project was to develop a generic sampling and analytical methodology to characterize the polynuclear aromatic hydrocarbon (PAH) concentrations in air within various microenvironments. The following three studies were performed: evaluation of analytical metho...

  5. TECHNOLOGY EVALUATION REPORT CEREX ENVIRONMENTAL SERVICES UV HOUND POINT SAMPLE AIR MONITOR

    EPA Science Inventory

    The USEPA's National Homeland Security Research Center (NHSRC) Technology Testing and Evaluation Program (TTEP) is carrying out performance tests on homeland security technologies. Under TTEP, Battelle evaluated the performance of the Cerex UV Hound point sample air monitor in de...

  6. NEW APPLICATION OF PASSIVE SAMPLING DEVICES FOR ASSESSMENT OF RESPIRATORY EXPOSURE TO PESTICIDES IN INDOOR AIR

    EPA Science Inventory

    The United States Environmental Protection Agency (EPA) has long maintained an interest in potential applications of passive sampling devices (PSDs) for estimating the concentrations of various pollutants in air. Typically PSDs were designed for the workplace monitoring of vola...

  7. Micropyrolyzer for chemical analysis of liquid and solid samples

    DOEpatents

    Mowry, Curtis D.; Morgan, Catherine H.; Manginell, Ronald P.; Frye-Mason, Gregory C.

    2006-07-18

    A micropyrolyzer has applications to pyrolysis, heated chemistry, and thermal desorption from liquid or solid samples. The micropyrolyzer can be fabricated from semiconductor materials and metals using standard integrated circuit technologies. The micropyrolyzer enables very small volume samples of less than 3 microliters and high sample heating rates of greater than 20.degree. C. per millisecond. A portable analyzer for the field analysis of liquid and solid samples can be realized when the micropyrolyzer is combined with a chemical preconcentrator, chemical separator, and chemical detector. Such a portable analyzer can be used in a variety of government and industrial applications, such as non-proliferation monitoring, chemical and biological warfare detection, industrial process control, water and air quality monitoring, and industrial hygiene.

  8. A novel Whole Air Sample Profiler (WASP) for the quantification of volatile organic compounds in the boundary layer

    SciTech Connect

    Mak, J. E.; Su, L.; Guenther, Alex B.; Karl, Thomas G.

    2013-10-16

    The emission and fate of reactive VOCs is of inherent interest to those studying chemical biosphere-atmosphere interactions. In-canopy VOC observations are obtainable using tower-based samplers, but the lack of suitable sampling systems for the full boundary 5 layer has limited the data characterizing the vertical structure of such gases above the canopy height and still in the boundary layer. This is the important region where many reactive VOCs are oxidized or otherwise removed. Here we describe an airborne sampling system designed to collect a vertical profile of air into a 3/800 OD tube 150m in length. The inlet ram air pressure is used to flow sampled air through the 10 tube, which results in a varying flow rate based on aircraft speed and altitude. Since aircraft velocity decreases during ascent, it is necessary to account for the variable flow rate into the tube. This is accomplished using a reference gas that is pulsed into the air stream so that the precise altitude of the collected air can be reconstructed post-collection. The pulsed injections are also used to determine any significant effect 15 from diffusion/mixing within the sampling tube, either during collection or subsequent extraction for gas analysis. This system has been successfully deployed, and we show some measured vertical profiles of isoprene and its oxidation products methacrolein and methyl vinyl ketone from a mixed canopy near Columbia, Missouri.

  9. Comparison of stationary and personal air sampling with an air dispersion model for children’s ambient exposure to manganese

    EPA Science Inventory

    Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to asse...

  10. Analysis of lunar samples for carbon compounds.

    NASA Technical Reports Server (NTRS)

    Kvenvolden, K. A.

    1971-01-01

    Description of one approach to the analysis for carbon compounds in lunar materials from the Apollo 11 mission. The sequential scheme followed generally accepted organic geochemical practices, but was unusual in its application to a single sample. The procedures of the scheme were designed to minimize handling of the solids and extracts or hydrolysates. The solid lunar sample was retained in all steps of the sequential analysis in the vessel in which it was originally placed. Centrifugation was used to separate solid and liquid phases after extraction or refluxing. Liquids were recovered from solids by decantation.

  11. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    PubMed

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration. PMID:21793731

  12. Sampling and analysis information aids for stationary source personnel

    SciTech Connect

    Jackson, M.D.; Johnson, L.D.

    1994-12-31

    The Environmental Protection Agency, in developing and evaluating samples and analysis methodology for stationary sources, has compiled information on availability and applicability of sampling and analytical methods. Information has also been summarized on the applicability of the gas chromatography/mass spectrometry as the analytical method. All of this information is accessible in three documents: ``Stationary Source Sampling and Analysis Directory, Version 2`` (SSSADIR), ``Handbook of GC/MS Data and Information for Selected Clean Air Act Amendments Compounds`` (Handbook), and ``Literature Review of CAAA Compounds`` (LitRev). The SSSADIR has information on which sampling and analytical methods to use for organic compounds listed in Title 3 of the Clean Air Act Amendments (CAAA) of 1990, as well as Appendices 8 and 9 of RCRA compounds, and the status of method evaluation for these analytes. The Handbook provides information on the mass spectra of selected CAAA analytes, primary quantitation ions, relative retention times and compatibility of the organic compounds in solution. The LitRev provides information on CAAA compounds for which EPA has no potential methods available but provides suggestions on ways to develop methods.

  13. Ion beam analysis of radioactive samples

    NASA Astrophysics Data System (ADS)

    Raepsaet, C.; Khodja, H.; Bossis, P.; Pipon, Y.; Roudil, D.

    2009-06-01

    The nuclear microprobe facility of the Pierre Süe Laboratory is fitted with two microbeam lines. One is dedicated to non-active samples. The other one, located in a controlled shielded area, offers the unique feature of being devoted to radioactive samples. Operational since 1998, it is strongly linked to nuclear research programs and has been dimensioned to accept radioactive but non-contaminant radioactive samples, including small quantities of UOX or MOX irradiated fuel. The samples, transported in a shipping cask, are unloaded and handled in hot cells with slaved arms. The analysis chamber, situated in a concrete cell, is equipped with charged particle detectors and a Si(Li) X-ray detector, shielded in order to reduce the radioactive noise produced by the sample, allowing ERDA, RBS, NRA and PIXE. After a description of the facility, including the sample handling in the hot cells and the analysis chamber, we will give an overview of the various experimental programs which have been performed, with an emphasis on the determination of the hydrogen distribution and local content in nuclear fuel cladding tubes.

  14. Method for preconcentrating a sample for subsequent analysis

    DOEpatents

    Zaromb, Solomon

    1990-01-01

    A system for analysis of trace concentration of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.

  15. Exploratory Factor Analysis with Small Sample Sizes

    ERIC Educational Resources Information Center

    de Winter, J. C. F.; Dodou, D.; Wieringa, P. A.

    2009-01-01

    Exploratory factor analysis (EFA) is generally regarded as a technique for large sample sizes ("N"), with N = 50 as a reasonable absolute minimum. This study offers a comprehensive overview of the conditions in which EFA can yield good quality results for "N" below 50. Simulations were carried out to estimate the minimum required "N" for different…

  16. Analysis of Picattiny Sample for Trace Explosives

    SciTech Connect

    Klunder, G; Whipple, R; Carman, L; Spackman, P E; Reynolds, J; Alcaraz, A

    2008-05-23

    The sample received from Picatinny Arsenal was analyzed for trace amounts of high explosives (HE). A complete wash of the surface was performed, concentrated, and analyzed using two sensitive analysis techniques that are capable of detecting numerous types of explosives. No explosives were detected with either test.

  17. TECHNICAL MANUAL FOR INORGANIC SAMPLING AND ANALYSIS

    EPA Science Inventory

    The manual presents the state-of-the-art of inorganic sampling and analysis (ISA) procedures in a standardized format that makes the methodology readily available to professionals in the field. Because of the breadth of ISA, a system was developed to avoid burying specific method...

  18. COAL SAMPLING AND ANALYSIS: METHODS AND MODELS

    EPA Science Inventory

    The report provides information on coal sampling and analysis (CSD) techniques and procedures and presents a statistical model for estimating SO2 emissions. (New Source Performance Standards for large coal-fired boilers and certain State Implementation Plans require operators to ...

  19. Air Force geographic information and analysis system

    SciTech Connect

    Henney, D.A.; Jansing, D.S.; Durfee, R.C.; Margle, S.M.; Till, L.E.

    1987-01-01

    A microcomputer-based geographic information and analysis system (GIAS) was developed to assist Air Force planners with environmental analysis, natural resources management, and facility and land-use planning. The system processes raster image data, topological data structures, and geometric or vector data similar to that produced by computer-aided design and drafting (CADD) systems, integrating the data where appropriate. Data types included Landsat imagery, scanned images of base maps, digitized point and chain features, topographic elevation data, USGS stream course data, highway networks, railroad networks, and land use/land cover information from USGS interpreted aerial photography. The system is also being developed to provide an integrated display and analysis capability with base maps and facility data bases prepared on CADD systems. 3 refs.

  20. Ground-based air-sampling measurements near the Nevada Test Site after atmospheric nuclear tests.

    PubMed

    Cederwall, R T; Ricker, Y E; Cederwall, P L; Homan, D N; Anspaugh, L R

    1990-11-01

    Historical air-sampling data measured within 320 km (200 mi) of the Nevada Test Site (NTS) have been reviewed for periods following atmospheric nuclear tests, primarily in the 1950s. These data come mostly from high-volume air samplers, with some from cascade-impactor samplers. Measurements considered here are for beta radiation from gross fission products. The resulting air-quality data base is comprised of almost 13,000 samples from 42 sampling locations downwind of the NTS. In order to compile an accurate air-quality data base for use in estimating exposure via inhalation, raw data values were sought where possible, and the required calculations were performed on a computer with state-of-the-art algorithms. The data-processing procedures consisted of (1) entry and error checking of historical data; (2) determination of appropriate background values, air-sampling volumes, and net air concentrations; and (3) calculation of integrated air concentration (C) for each sample (considering fallout arrival times). Comparing C values for collocated high-volume and cascade-impactor samplers during the Upshot-Knothole series showed similar lognormal distributions, but with a geometric mean C for cascade impactors about half that for the high-volume air samplers. Overall, the uncertainty in C values is about a factor of three. In the past, it has been assumed that C could be related to ground deposition by a constant having units of velocity. In our data bases, simultaneous measurements of air concentration and ground deposition at the same locations were not related by a constant; indeed, there was a great amount of scatter. This suggests that the relationship between C and ground deposition in this situation is too complex to be treated adequately by simple approaches. PMID:2211113

  1. Ground-based air-sampling measurements near the Nevada Test Site after atmospheric nuclear tests

    SciTech Connect

    Cederwall, R.T.; Ricker, Y.E.; Cederwall, P.L.; Homan, D.N.; Anspaugh, L.R. )

    1990-11-01

    Historical air-sampling data measured within 320 km (200 mi) of the Nevada Test Site (NTS) have been reviewed for periods following atmospheric nuclear tests, primarily in the 1950s. These data come mostly from high-volume air samplers, with some from cascade-impactor samplers. Measurements considered here are for beta radiation from gross fission products. The resulting air-quality data base is comprised of almost 13,000 samples from 42 sampling locations downwind of the NTS. In order to compile an accurate air-quality data base for use in estimating exposure via inhalation, raw data values were sought where possible, and the required calculations were performed on a computer with state-of-the-art algorithms. The data-processing procedures consisted of (1) entry and error checking of historical data; (2) determination of appropriate background values, air-sampling volumes, and net air concentrations; and (3) calculation of integrated air concentration (C) for each sample (considering fallout arrival times). Comparing C values for collocated high-volume and cascade-impactor samplers during the Upshot-Knothole series showed similar lognormal distributions, but with a geometric mean C for cascade impactors about half that for the high-volume air samplers. Overall, the uncertainty in C values is about a factor of three. In the past, it has been assumed that C could be related to ground deposition by a constant having units of velocity. In our data bases, simultaneous measurements of air concentration and ground deposition at the same locations were not related by a constant; indeed, there was a great amount of scatter. This suggests that the relationship between C and ground deposition in this situation is too complex to be treated adequately by simple approaches.

  2. Animation of TEGA Sample Delivery and Analysis

    NASA Technical Reports Server (NTRS)

    2008-01-01

    [figure removed for brevity, see original site] Click on image to view the animation

    This animation shows NASA's Phoenix Lander's Robotic Arm scoop delivering a sample to the Thermal and Evolved-Gas Analyzer (TEGA) and how samples are analyzed within the instrument.

    TEGA has eight tiny ovens for measuring constituents in the atmosphere and in the soil, including possible organic constituents and the melting point of ice.

    The scoop drops soil onto a fine mesh screen between TEGA's open doors. Some soil passes through the screen, which vibrates, into the throat of a funnel, where a spinning device called the 'whirligig' aids delivery into one half of a tiny oven. The soil sample is represented here by the white chip. The filled oven half then rotates and mates with the other oven half, closing the complete oven so sample heating can begin. The purple coil in this animation is the spring that moves the oven halves together.

    Heating occurs at successively higher temperatures over several days. The energy required to heat the sample is measured to discover its thermal properties. Gases driven off during sample heating pass through tubing to the mass spectrometer for analysis.

    Note that the exterior doors above the screen never close after sample delivery.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  3. TEGA Sample Delivery and Analysis (Animation)

    NASA Technical Reports Server (NTRS)

    2008-01-01

    [figure removed for brevity, see original site] Click on image for animation

    This animation shows NASA's Phoenix Lander's Robotic Arm scoop delivering a sample to the Thermal and Evolved-Gas Analyzer (TEGA) and how samples are analyzed within the instrument.

    TEGA has eight tiny ovens for measuring constituents in the atmosphere and in the soil, including possible organic constituents and the melting point of ice.

    The scoop drops soil onto a fine mesh screen between TEGA's open doors. Some soil passes through the screen, which vibrates, into the throat of a funnel, where a spinning device called the 'whirligig' aids delivery into one half of a tiny oven. The soil sample is represented here by the white chip. The filled oven half then rotates and mates with the other oven half, closing the complete oven so sample heating can begin. The purple coil in this animation is the spring that moves the oven halves together.

    Heating occurs at successively higher temperatures over several days. The energy required to heat the sample is measured to discover its thermal properties. Gases driven off during sample heating pass through tubing to the mass spectrometer for analysis.

    Note that the exterior doors above the screen never close after sample delivery.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASAaE(TM)s Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  4. An analytical method for trifluoroacetic Acid in water and air samples using headspace gas chromatographic determination of the methyl ester.

    PubMed

    Zehavi, D; Seiber, J N

    1996-10-01

    An analytical method has been developed for the determination of trace levels of trifluoroacetic acid (TFA), an atmospheric breakdown product of several of the hydrofluorocarbon (HFC) and hydrochlorofluorocarbon (HCFC) replacements for the chlorofluorocarbon (CFC) refrigerants, in water and air. TFA is derivatized to the volatile methyl trifluoroacetate (MTFA) and determined by automated headspace gas chromatography (HSGC) with electron-capture detection or manual HSGC using GC/MS in the selected ion monitoring (SIM) mode. The method is based on the reaction of an aqueous sample containing TFA with dimethyl sulfate (DMS) in concentrated sulfuric acid in a sealed headspace vial under conditions favoring distribution of MTFA to the vapor phase. Water samples are prepared by evaporative concentration, during which TFA is retained as the anion, followed by extraction with diethyl ether of the acidified sample and then back-extraction of TFA (as the anion) in aqueous bicarbonate solution. The extraction step is required for samples with a relatively high background of other salts and organic materials. Air samples are collected in sodium bicarbonate-glycerin-coated glass denuder tubes and prepared by rinsing the denuder contents with water to form an aqueous sample for derivatization and analysis. Recoveries of TFA from spiked water, with and without evaporative concentration, and from spiked air were quantitative, with estimated detection limits of 10 ng/mL (unconcentrated) and 25 pg/mL (concentrated 250 mL:1 mL) for water and 1 ng/m(3) (72 h at 5 L/min) for air. Several environmental air, fogwater, rainwater, and surface water samples were successfully analyzed; many showed the presence of TFA. PMID:21619278

  5. Double Shell Tank (DST) Ventilation System Vapor Sampling and Analysis Plan

    SciTech Connect

    SASAKI, L.M.

    2000-06-08

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples from the primary ventilation systems of the AN, AP, AW, and AY/AZ tank farms. Sampling will be performed in accordance with Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Air DQO) (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications. Vapor samples will be obtained from tank farm ventilation systems, downstream from the tanks and upstream of any filtration. Samples taken in support of the DQO will consist of SUMMA{trademark} canisters, triple sorbent traps (TSTs), sorbent tube trains (STTs), polyurethane foam (PUF) samples. Particulate filter samples and tritium traps will be taken for radiation screening to allow the release of the samples for analysis. The following sections provide the general methodology and procedures to be used in the preparation, retrieval, transport, analysis, and reporting of results from the vapor samples.

  6. Estimating Sampling Biases and Measurement Uncertainties of AIRS-AMSU-A Temperature and Water Vapor Observations Using MERRA Reanalysis

    NASA Technical Reports Server (NTRS)

    Hearty, Thomas J.; Savtchenko, Andrey K.; Tian, Baijun; Fetzer, Eric; Yung, Yuk L.; Theobald, Michael; Vollmer, Bruce; Fishbein, Evan; Won, Young-In

    2014-01-01

    We use MERRA (Modern Era Retrospective-Analysis for Research Applications) temperature and water vapor data to estimate the sampling biases of climatologies derived from the AIRS/AMSU-A (Atmospheric Infrared Sounder/Advanced Microwave Sounding Unit-A) suite of instruments. We separate the total sampling bias into temporal and instrumental components. The temporal component is caused by the AIRS/AMSU-A orbit and swath that are not able to sample all of time and space. The instrumental component is caused by scenes that prevent successful retrievals. The temporal sampling biases are generally smaller than the instrumental sampling biases except in regions with large diurnal variations, such as the boundary layer, where the temporal sampling biases of temperature can be +/- 2 K and water vapor can be 10% wet. The instrumental sampling biases are the main contributor to the total sampling biases and are mainly caused by clouds. They are up to 2 K cold and greater than 30% dry over mid-latitude storm tracks and tropical deep convective cloudy regions and up to 20% wet over stratus regions. However, other factors such as surface emissivity and temperature can also influence the instrumental sampling bias over deserts where the biases can be up to 1 K cold and 10% wet. Some instrumental sampling biases can vary seasonally and/or diurnally. We also estimate the combined measurement uncertainties of temperature and water vapor from AIRS/AMSU-A and MERRA by comparing similarly sampled climatologies from both data sets. The measurement differences are often larger than the sampling biases and have longitudinal variations.

  7. An evaluation of analytical methods, air sampling techniques, and airborne occupational exposure of metalworking fluids.

    PubMed

    Verma, Dave K; Shaw, Don S; Shaw, M Lorraine; Julian, Jim A; McCollin, Shari-Ann; des Tombe, Karen

    2006-02-01

    This article summarizes an assessment of air sampling and analytical methods for both oil and water-based metalworking fluids (MWFs). Three hundred and seventy-four long-term area and personal airborne samples were collected at four plants using total (closed-face) aerosol samplers and thoracic samplers. A direct-reading device (DustTrak) was also used. The processes sampled include steel tube making, automotive component manufacturing, and small part manufacturing in a machine shop. The American Society for Testing and Materials (ASTM) Method PS42-97 of analysis was evaluated in the laboratory. This evaluation included sample recovery, determination of detection limits, and stability of samples during storage. Results of the laboratory validation showed (a) the sample recovery to be about 87%, (b) the detection limit to be 35 microg, and (c) sample stability during storage at room temperature to decline rapidly within a few days. To minimize sample loss, the samples should be stored in a freezer and analyzed within a week. The ASTM method should be the preferred method for assessing metalworking fluids (MWFs). The ratio of thoracic aerosol to total aerosol ranged from 0.6 to 0.7. A similar relationship was found between the thoracic extractable aerosol and total extractable aerosol. The DustTrak, with 10-microm sampling head, was useful in pinpointing the areas of potential exposure. MWF exposure at the four plants ranged from 0.04 to 3.84 mg/m3 with the geometric mean ranging between 0.22 to 0.59 mg/m3. Based on this data and the assumption of log normality, MWF exposures are expected to exceed the National Institute for Occupational Safety and Health recommended exposure limit of 0.5 mg/m3 as total mass and 0.4 mg/m3 as thoracic mass about 38% of the time. In addition to controlling airborne MWF exposure, full protection of workers would require the institution of programs for fluid management and dermal exposure prevention. PMID:16361218

  8. Germanium-76 Sample Analysis: Revision 3

    SciTech Connect

    Kouzes, Richard T.; Zhu, Zihua; Engelhard, Mark H.

    2011-09-19

    The MAJORANA DEMONSTRATOR is a large array of ultra-low background high-purity germanium detectors, enriched in 76Ge, designed to search for zero-neutrino double-beta decay (0{nu}{beta}{beta}). The DEMONSTRATOR will utilize 76Ge from Russia. The first one-gram sample was received from the supplier for analysis on April 24, 2011. The second one-gram sample was received from the supplier for analysis on July 12, 2011. The third sample, which came from the first large shipment of germanium from the vendor, was received from Oak Ridge National Laboratory (ORNL) on September 13, 2011. The Environmental Molecular Sciences facility, a DOE user facility at PNNL, was used to make the required isotopic and chemical purity measurements that are essential to the quality assurance for the MAJORANA DEMONSTRATOR. The results of these analyses are reported here. The isotopic composition of a sample of natural germanium was also measured twice. Differences in the result between these two measurements led to a re-measurement of the second 76Ge sample.

  9. OVERVIEW OF BERYLLIUM SAMPLING AND ANALYSIS

    SciTech Connect

    Brisson, M

    2009-04-01

    Because of its unique properties as a lightweight metal with high tensile strength, beryllium is widely used in applications including cell phones, golf clubs, aerospace, and nuclear weapons. Beryllium is also encountered in industries such as aluminium manufacturing, and in environmental remediation projects. Workplace exposure to beryllium particulates is a growing concern, as exposure to minute quantities of anthropogenic forms of beryllium may lead to sensitization and to chronic beryllium disease, which can be fatal and for which no cure is currently known. Furthermore, there is no known exposure-response relationship with which to establish a 'safe' maximum level of beryllium exposure. As a result, the current trend is toward ever lower occupational exposure limits, which in turn make exposure assessment, both in terms of sampling and analysis, more challenging. The problems are exacerbated by difficulties in sample preparation for refractory forms of beryllium, such as beryllium oxide, and by indications that some beryllium forms may be more toxic than others. This chapter provides an overview of sources and uses of beryllium, health risks, and occupational exposure limits. It also provides a general overview of sampling, analysis, and data evaluation issues that will be explored in greater depth in the remaining chapters. The goal of this book is to provide a comprehensive resource to aid personnel in a wide variety of disciplines in selecting sampling and analysis methods that will facilitate informed decision-making in workplace and environmental settings.

  10. Using Ancient Samples in Projection Analysis

    PubMed Central

    Yang, Melinda A.; Slatkin, Montgomery

    2015-01-01

    Projection analysis is a tool that extracts information from the joint allele frequency spectrum to better understand the relationship between two populations. In projection analysis, a test genome is compared to a set of genomes from a reference population. The projection’s shape depends on the historical relationship of the test genome’s population to the reference population. Here, we explore in greater depth the effects on the projection when ancient samples are included in the analysis. First, we conduct a series of simulations in which the ancient sample is directly ancestral to a present-day population (one-population model), or the ancient sample is ancestral to a sister population that diverged before the time of sampling (two-population model). We find that there are characteristic differences between the projections for the one-population and two-population models, which indicate that the projection can be used to determine whether a test genome is directly ancestral to a present-day population or not. Second, we compute projections for several published ancient genomes. We compare two Neanderthals and three ancient human genomes to European, Han Chinese and Yoruba reference panels. We use a previously constructed demographic model and insert these five ancient genomes to assess how well the observed projections are recovered. PMID:26546309

  11. Using Ancient Samples in Projection Analysis.

    PubMed

    Yang, Melinda A; Slatkin, Montgomery

    2016-01-01

    Projection analysis is a tool that extracts information from the joint allele frequency spectrum to better understand the relationship between two populations. In projection analysis, a test genome is compared to a set of genomes from a reference population. The projection's shape depends on the historical relationship of the test genome's population to the reference population. Here, we explore in greater depth the effects on the projection when ancient samples are included in the analysis. First, we conduct a series of simulations in which the ancient sample is directly ancestral to a present-day population (one-population model), or the ancient sample is ancestral to a sister population that diverged before the time of sampling (two-population model). We find that there are characteristic differences between the projections for the one-population and two-population models, which indicate that the projection can be used to determine whether a test genome is directly ancestral to a present-day population or not. Second, we compute projections for several published ancient genomes. We compare two Neanderthals and three ancient human genomes to European, Han Chinese and Yoruba reference panels. We use a previously constructed demographic model and insert these five ancient genomes to assess how well the observed projections are recovered. PMID:26546309

  12. Sampling and Data Analysis for Environmental Microbiology

    SciTech Connect

    Murray, Christopher J.

    2001-06-01

    A brief review of the literature indicates the importance of statistical analysis in applied and environmental microbiology. Sampling designs are particularly important for successful studies, and it is highly recommended that researchers review their sampling design before heading to the laboratory or the field. Most statisticians have numerous stories of scientists who approached them after their study was complete only to have to tell them that the data they gathered could not be used to test the hypothesis they wanted to address. Once the data are gathered, a large and complex body of statistical techniques are available for analysis of the data. Those methods include both numerical and graphical techniques for exploratory characterization of the data. Hypothesis testing and analysis of variance (ANOVA) are techniques that can be used to compare the mean and variance of two or more groups of samples. Regression can be used to examine the relationships between sets of variables and is often used to examine the dependence of microbiological populations on microbiological parameters. Multivariate statistics provides several methods that can be used for interpretation of datasets with a large number of variables and to partition samples into similar groups, a task that is very common in taxonomy, but also has applications in other fields of microbiology. Geostatistics and other techniques have been used to examine the spatial distribution of microorganisms. The objectives of this chapter are to provide a brief survey of some of the statistical techniques that can be used for sample design and data analysis of microbiological data in environmental studies, and to provide some examples of their use from the literature.

  13. Detection of airborne bacteria in a duck production facility with two different personal air sampling devices for an exposure assessment.

    PubMed

    Martin, Elena; Dziurowitz, Nico; Jäckel, Udo; Schäfer, Jenny

    2015-01-01

    Prevalent airborne microorganisms are not well characterized in industrial animal production buildings with respect to their quantity or quality. To investigate the work-related microbial exposure, personal bioaerosol sampling during the whole working day is recommended. Therefore, bioaerosol sampling in a duck hatchery and a duck house with two personal air sampling devices, a filter-based PGP and a NIOSH particle size separator, was performed. Subsequent, quantitative and qualitative analyses were carried out with" culture independent methods. Total cell concentrations (TCC) determined via fluorescence microscopy showed no difference between the two devices. In average, 8 × 10(6) cells/m(3) were determined in the air of the duck hatchery and 5 × 10(7) cells/m(3) in the air of the duck house. A Generated Restriction Fragment Length Polymorphism (RFLP) pattern revealed deviant bacterial compositions comparing samples collected with both devices. Clone library analyses based on 16S rRNA gene sequence analysis from the hatchery's air showed 65% similarity between the two sampling devices. Detailed 16S rRNA gene sequence analyses showed the occurrence of bacterial species like Acinetobacter baumannii, Enterococcus faecalis, Escherichia sp., and Shigella sp.; and a group of Staphylococcus delphini, S. intermedius, and S. pseudintermedius that provided the evidence of potential exposure to risk group 2 bacteria at the hatchery workplace. Size fractionated sampling with the developed by the Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA) device revealed that pathogenic bacteria would deposit in the inhalable, the thorax, and possibly alveolar dust fraction according to EN481. TCC analysis showed the deposition of bacterial cells in the third stage (< 1μm) at the NIOSH device which implies that bacteria can reach deep into the lungs and contaminate the alveolus after inhalation. Nevertheless, both personal sampling devices

  14. Microbial counts and particulate matter levels in roadside air samples under skytrain stations, Bangkok, Thailand.

    PubMed

    Luksamijarulkul, Pipat; Kongtip, Pornpimol

    2010-05-01

    In conditions with heavy traffic and crowds of people on roadside areas under skytrain stations in Bangkok, the natural air ventilation may be insufficient and air quality may be poor. A study of 350 air samples collected from the roadside, under skytrain stations in Bangkok, was carried out to assess microbial counts (210 air samples) and particulate matter (PM10) levels (140 samples). The results reveal the mean +/- standard deviation bacterial counts and fungal counts were 406.8 +/- 302.7 cfu/m3 and 128.9 +/- 89.7 cfu/m3, respectively. The PM10 level was 186.1 +/- 188.1 microg/m3. When compared to recommended levels, 4.8% of air samples (10/210 samples) had bacterial counts more than recommended levels (> 1,000 cfu/ m3) and 27.1% (38/140 samples) had PM10 levels more than recommended levels (> 120 microg/m3). These may affect human health, especially of street venders who spend most of their working time in these areas. PMID:20578558

  15. Uncertainties in Air Exchange using Continuous-Injection, Long-Term Sampling Tracer-Gas Methods

    SciTech Connect

    Sherman, Max H.; Walker, Iain S.; Lunden, Melissa M.

    2013-12-01

    The PerFluorocarbon Tracer (PFT) method is a low-cost approach commonly used for measuring air exchange in buildings using tracer gases. It is a specific application of the more general Continuous-Injection, Long-Term Sampling (CILTS) method. The technique is widely used but there has been little work on understanding the uncertainties (both precision and bias) associated with its use, particularly given that it is typically deployed by untrained or lightly trained people to minimize experimental costs. In this article we will conduct a first-principles error analysis to estimate the uncertainties and then compare that analysis to CILTS measurements that were over-sampled, through the use of multiple tracers and emitter and sampler distribution patterns, in three houses. We find that the CILTS method can have an overall uncertainty of 10-15percent in ideal circumstances, but that even in highly controlled field experiments done by trained experimenters expected uncertainties are about 20percent. In addition, there are many field conditions (such as open windows) where CILTS is not likely to provide any quantitative data. Even avoiding the worst situations of assumption violations CILTS should be considered as having a something like a ?factor of two? uncertainty for the broad field trials that it is typically used in. We provide guidance on how to deploy CILTS and design the experiment to minimize uncertainties.

  16. Nano-FTIR for Geochemical Sample Analysis

    NASA Astrophysics Data System (ADS)

    Dominguez, G.; McCleod, A.; Gainsforth, Z.; Keilmann, F.; Westphal, A.; Thiemens, M. H.; Basov, D.

    2014-12-01

    Infrared (IR) spectroscopy is considered by many to be the "gold standard" for chemical identification, providing a direct connection between chemical compounds found in the laboratory and those found in natural samples including remote astrophysical environments. However, a well known limitation of using conventional IR spectroscopy is its spatial resolution determined by the wavelength of IR photons. Thus, while other techniques such as XANES and micro-Raman are capable of limited functional group mapping at tens to hundreds of nanometers, their use is limited by accessibility (the need for synchrotron beamlines) or the need for intense irradiation conditions (Raman) that can lead to sample alteration. These limitations and the wealth of information that can be extracted from detailed studies of unique micron-sized samples brought back by recent sample return missions such as NASA's Stardust mission, have motivated the development of a novel infrared mapping technique that is capable of mapping the chemical functional properties of geochemical samples with submicron resolutions. Here we describe our nano-FTIR imaging and analysis technique that allows us to bypass diffraction limited sample imaging in the infrared. Here we show, for the first time, that 1) the combination of an atomic-force microscope (AFM) and laser can be used to obtain the FTIR-equivalent spectra on spatial scales that are much smaller than the wavelength of IR radiation used 2) this technique responds to subtle shifts in cation concentrations as evidenced by changes in the frequencies of phonons at sub-micron scales 3) this technique can be used to identify regions of crystalline and semi-crystalline materials as demonstrated in our analysis of a cometary dust grain Iris. This work has clear implications for interpretations of astronomical observations and adds a new technique for the non-destructive characterization of terrestrial and extraterrestrial samples.

  17. Development of a multicopter-carried whole air sampling apparatus and its applications in environmental studies.

    PubMed

    Chang, Chih-Chung; Wang, Jia-Lin; Chang, Chih-Yuan; Liang, Mao-Chang; Lin, Ming-Ren

    2016-02-01

    To advance the capabilities of probing chemical composition aloft, we designed a lightweight remote-controlled whole air sampling component (WASC) and integrated it into a multicopter drone with agile maneuverability to perform aerial whole air sampling. A field mission hovering over an exhaust shaft of a roadway tunnel to collect air samples was performed to demonstrate the applicability of the multicopter-carried WASC apparatus. Ten aerial air samples surrounding the shaft vent were collected by the multicopter-carried WASC. Additional five samples were collected manually inside the shaft for comparison. These samples were then analyzed in the laboratory for the chemical composition of 109 volatile organic compounds (VOCs), CH4, CO, CO2, or CO2 isotopologues. Most of the VOCs in the upwind samples (the least affected by shaft exhaust) were low in concentrations (5.9 ppbv for total 109 VOCs), posting a strong contrast to those in the shaft exhaust (235.8 ppbv for total 109 VOCs). By comparing the aerial samples with the in-shaft samples for chemical compositions, the influence of the shaft exhaust on the surrounding natural air was estimated. Through the aerial measurements, three major advantages of the multicopter-carried WASC were demonstrated: 1. The highly maneuverable multicopter-carried WASC can be readily deployed for three-dimensional environmental studies at a local scale (0-1.5 km); 2. Aerial sampling with superior sample integrity and preservation conditions can now be performed with ease; and 3. Data with spatial resolution for a large array of gaseous species with high precision can be easily obtained. PMID:26386435

  18. Marine Technician's Handbook, Instructions for Taking Air Samples on Board Ship: Carbon Dioxide Project.

    ERIC Educational Resources Information Center

    Keeling, Charles D.

    This booklet is one of a series intended to provide explicit instructions for the collection of oceanographic data and samples at sea. The methods and procedures described have been used by the Scripps Institution of Oceanography and found reliable and up-to-date. Instructions are given for taking air samples on board ship to determine the…

  19. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Approved sampling devices; operation; air flowrate. 90.205 Section 90.205 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures §...

  20. DEVELOPMENT OF A SUB-SLAB AIR SAMPLING PROTOCOL TO SUPPORT ASSESSMENT OF VAPOR INTRUSION

    EPA Science Inventory

    The primary purpose of this research effort is to develop a methodology for sub-slab sampling to support the EPA guidance and vapor intrusion investigations after vapor intrusion has been established at a site. Methodologies for sub-slab air sampling are currently lacking in ref...

  1. EVALUATION OF THE FILTER PACK FOR LONG-DURATION SAMPLING OF AMBIENT AIR

    EPA Science Inventory

    A 14-week filter pack (FP) sampler evaluation field study was conducted at a site near Bondville, IL to investigate the impact of weekly sampling duration. Simultaneous samples were collected using collocated filter packs (FP) from two independent air quality monitoring networks...

  2. QA/QC requirements for physical properties sampling and analysis

    SciTech Connect

    Innis, B.E.

    1993-07-21

    This report presents results of an assessment of the available information concerning US Environmental Protection Agency (EPA) quality assurance/quality control (QA/QC) requirements and guidance applicable to sampling, handling, and analyzing physical parameter samples at Comprehensive Environmental Restoration, Compensation, and Liability Act (CERCLA) investigation sites. Geotechnical testing laboratories measure the following physical properties of soil and sediment samples collected during CERCLA remedial investigations (RI) at the Hanford Site: moisture content, grain size by sieve, grain size by hydrometer, specific gravity, bulk density/porosity, saturated hydraulic conductivity, moisture retention, unsaturated hydraulic conductivity, and permeability of rocks by flowing air. Geotechnical testing laboratories also measure the following chemical parameters of soil and sediment samples collected during Hanford Site CERCLA RI: calcium carbonate and saturated column leach testing. Physical parameter data are used for (1) characterization of vadose and saturated zone geology and hydrogeology, (2) selection of monitoring well screen sizes, (3) to support modeling and analysis of the vadose and saturated zones, and (4) for engineering design. The objectives of this report are to determine the QA/QC levels accepted in the EPA Region 10 for the sampling, handling, and analysis of soil samples for physical parameters during CERCLA RI.

  3. Laboratory validation and field verification of a new passive colorimetric air monitoring badge for sampling hydrogen sulfide in air.

    PubMed

    Kring, E V; Damrell, D J; Henry, T J; DeMoor, H M; Basilio, A N; Simon, C E

    1984-01-01

    The Pro-Tek passive colorimetric air monitoring badge for personal or area sampling of hydrogen sulfide is described. The badge has been validated over the range of 1.8 to 164 ppm-hours (0.23-21 ppm on an 8-hour TWA basis). It has an overall accuracy throughout this range of +/- 15.9% and meets the NIOSH accuracy criteria for an analytical and sampling method. The colorimetric analytical method used is based on the Texas Air Control Board's Molybdenum Blue method. Color-activated exposed badge solutions are read out on a standard laboratory spectrophotometer using 1 centimeter (10 mm) cells. Variations in exposure temperature (between 10 degrees and 40 degrees C), relative humidity, and face velocity (between 2 and 250 ft/min) do not affect badge performance. Unexposed badges are stable for more than 12 months refrigerated and for two months at room temperature. PMID:6702591

  4. Astrobiology Sample Analysis as a Design Driver

    NASA Technical Reports Server (NTRS)

    Cohen, Marc M.

    2001-01-01

    This effort supports the Astrobiology Objective 8 the Search for LIFE ON MARS PAST AND PRESENT -(Astrobiology Program Office, 1998, p.7). The essential trade analysis is between returning very small samples to the Earth while protecting them versus in situ analysis on Mars. Developing these explicit parameters encompasses design, instrumentation, system integration, human factors and surface operations for both alternatives. This allocation of capability approach incorporates a "humans and machines in the loop" model that recognizes that every exploration system involves both humans and automated systems. The question is where in the loop they occur whether on Earth, in the Mars Base, in the rover or creeping over the Mars surface.

  5. BACTERIOLOGICAL ANALYSIS WITH SAMPLING AND SAMPLE PRESERVATION SPECIFICS

    EPA Science Inventory

    Current federal regulations (40CFR 503) specify that under certain conditions treated municipal biosolids must be analyzed for fecal coliform or salmonellae. The regulations state that representative samples of biosolids must be collected and analyzed using standard methods. Th...

  6. Comparison of mold concentrations quantified by MSQPCR in indoor and outdoor air sampled simultaneously

    SciTech Connect

    Meklin, Teija; Reponen, Tina; McKinstry, Craig A.; Cho, Seung H.; Grinshpun, Sergey A.; Nevalainen, Aino; Vepsalainen, Asko; Haugland, Richard A.; Lemasters, Grace; Vesper, Sephen J.

    2007-08-15

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of 36 mold species in dust and in indoor and in outdoor air samples that were taken simultaneously in 17 homes in Cincinnati with no-known water damage. The total spore concentrations in the indoor (I) and outdoor (O) air samples were statistically significantly different and the concentrations in the three sample types of many of the individual species were significantly different (p < 0.05 based on the Wilcoxon Signed Rank Test). The I/O ratios of the averages or geometric means of the individual species were generally less than 1; but these I/O ratios were quite variable ranging from 0.03 for A. sydowii to 1.2 for Acremonium strictum. There were no significant correlations for the 36 specific mold concentrations between the dust samples and the indoor or outdoor air samples (based on the Spearman’s Rho test). The indoor and outdoor air concentrations of 32 of the species were not correlated. Only Aspergillus penicillioides, C. cladosporioides types 1 and 2 and C. herbarum had sufficient data to estimate a correlation at rho > 0.5 with signicance (p < 0.05) In six of these homes, a previous dust sample had been collected and analyzed 2 years earlier. The ERMI© values for the dust samples taken in the same home two years apart were not significantly different (p=0.22) based on Wilcoxon Signed Rank Test.

  7. Analysis of particulates on tape lift samples

    NASA Astrophysics Data System (ADS)

    Moision, Robert M.; Chaney, John A.; Panetta, Chris J.; Liu, De-Ling

    2014-09-01

    Particle counts on tape lift samples taken from a hardware surface exceeded threshold requirements in six successive tests despite repeated cleaning of the surface. Subsequent analysis of the particle size distributions of the failed tests revealed that the handling and processing of the tape lift samples may have played a role in the test failures. In order to explore plausible causes for the observed size distribution anomalies, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to perform chemical analysis on collected particulates. SEM/EDX identified Na and S containing particles on the hardware samples in a size range identified as being responsible for the test failures. ToF-SIMS was employed to further examine the Na and S containing particulates and identified the molecular signature of sodium alkylbenzene sulfonates, a common surfactant used in industrial detergent. The root cause investigation suggests that the tape lift test failures originated from detergent residue left behind on the glass slides used to mount and transport the tape following sampling and not from the hardware surface.

  8. Aerosol analysis for the regional air pollution study. Final report

    SciTech Connect

    Jaklevic, J.M.; Gatti, R.C.; Goulding, F.S.; Loo, B.W.; Thompson, A.C.

    1980-05-01

    The design and operation of an aerosol sampling and analysis program implemented during the 1975 to 1977 St. Louis Regional Air Pollution Study is described. A network of ten samplers were operated at selected sites in the St. Louis area and the total mass and elemental composition of the collected particulates were determined. Sampling periods of 2 to 24 hours were employed. The samplers were capable of collecting aerosol particles in two distinct size ranges corresponding to fine (< 2.4 ..mu..m diameter) and coarse (> 2.4 ..mu..m diameter) particles. This unique feature allowed the separation of the particulate samples into two distinct fractions with differing chemical origins and health effects. The analysis methods were also newly developed for use in the St. Louis RAPS study. Total particulate mass was measured by a beta-particle attenuation method in which a precision of +- 5 ..mu..m/cm/sup 2/ could be obtained in a one minute measurement time. Elemental compositions of the samples were determined using an energy dispersive x-ray fluorescence method in which detectable limits of 5 ng/cm/sup 2/ or less were routinely achieved for elements ranging in atomic number from Al to Pb. The advantages of these analytical methods over more conventional techniques arise from the ability to automate the measurements. During the course of the two year study, a total of more than 35,000 individual samples were processed and a total of 28 concentrations measured for each sample.

  9. Comparison of sampling methods for radiocarbon dating of carbonyls in air samples via accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    Schindler, Matthias; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander

    2016-05-01

    Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO2 and reduced to graphite to determine 14C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).

  10. Mars Analogue Field Research and Sample Analysis

    NASA Astrophysics Data System (ADS)

    Foing, Bernard H.

    2016-07-01

    We describe results from the data analysis from a series of field research campaigns (ILEWG EuroMoonMars campaigns 2009 to 2016) in the Utah desert and in other extreme environments (Iceland, Eifel, La Reunion) relevant to habitability and astrobiology in Mars environments, and in order to help in the interpretation of Mars missions measurements from orbit (MEX, MRO) or from the surface (MER, MSL). We discuss results relevant to the scientific study of the habitability factors influenced by the properties of dust, organics, water history and the diagnostics and characterisation of microbial life. We also discuss perspectives for the preparation of future lander and sample return missions. We deployed at Mars Desert Research station, Utah, a suite of instruments and techniques including sample collection, context imaging from remote to local and microscale, drilling, spectrometers and life sensors. We analyzed how geological and geochemical evolution affected local parameters (mineralogy, organics content, environment variations) and the habitability and signature of organics and biota. We find high diversity in the composition of soil samples even when collected in close proximity, the low abundances of detectable PAHs and amino acids and the presence of biota of all three domains of life with significant heterogeneity. An extraordinary variety of putative extremophiles was observed. A dominant factor seems to be soil porosity and lower clay-sized particle content. A protocol was developed for sterile sampling, contamination issues, and the diagnostics of biodiversity via PCR and DGGE analysis in soils and rocks samples. We compare campaign results from 2009-2013 campaigns in Utah and other sites to new measurements concerning: the comparison between remote sensing and in-situ measurements; the study of minerals; the detection of organics and signs of life.

  11. Mars Analogue Field Research and Sample Analysis

    NASA Astrophysics Data System (ADS)

    Foing, Bernard H.

    2016-07-01

    We describe results from the data analysis from a series of field research campaigns (ILEWG EuroMoonMars campaigns 2009 to 2016) in the Utah desert and in other extreme environments (Iceland, Eifel, La Reunion) relevant to habitability and astrobiology in Mars environments, and in order to help in the interpretation of Mars missions measurements from orbit (MEX, MRO) or from the surface (MER, MSL). We discuss results relevant to the scientific study of the habitability factors influenced by the properties of dust, organics, water history and the diagnostics and characterisation of microbial life. We also discuss perspectives for the preparation of future lander and sample return missions. We deployed at Mars Desert Research station, Utah, a suite of instruments and techniques including sample collection, context imaging from remote to local and microscale, drilling, spectrometers and life sensors. We analyzed how geological and geochemical evolution a ffected local parameters (mineralogy, organics content, environment variations) and the habitability and signature of organics and biota. We find high diversity in the composition of soil samples even when collected in close proximity, the low abundances of detectable PAHs and amino acids and the presence of biota of all three domains of life with significant heterogeneity. An extraordinary variety of putative extremophiles was observed. A dominant factor seems to be soil porosity and lower clay-sized particle content. A protocol was developed for sterile sampling, contamination issues, and the diagnostics of biodiversity via PCR and DGGE analysis in soils and rocks samples. We compare campaign results from 2009-2013 campaigns in Utah and other sites to new measurements concerning: the comparison between remote sensing and in-situ measurements; the study of minerals; the detection of organics and signs of life.

  12. A sample holder for measuring the magnetic properties of air-sensitive compounds

    NASA Astrophysics Data System (ADS)

    Berlie, Adam; Terry, Ian; Szablewski, Marek

    2011-01-01

    A sample holder is reported which has allowed the magnetic characterization of air-sensitive compounds to be made in a Quantum Design Magnetic Properties Measurement System as a function of the applied field (0-5 T), and at temperatures ranging from 2 to 290 K. The sample holder is in the form of a specially designed tube, which is made from high purity quartz, utilizes PTFE (polytetrafluoroethylene) plugs and is reusable. This construction also offers the benefit that no heat treatment of the holder is required during sample loading, making the sample holder suitable for thermally sensitive compounds. The application of this sample holder is demonstrated for the case of Ni(cod)2 (cod = 1,5-cyclooctadiene), a compound that decomposes when exposed to air and/or heat. This material's instability has, so far, prevented the magnetic characterization of the compound, with nickel nanoparticles, a product of the decomposition, usually being measured instead.

  13. SALI chemical analysis of provided samples

    NASA Technical Reports Server (NTRS)

    Becker, Christopher H.

    1993-01-01

    SRI has completed the chemical analysis of all the samples supplied by NASA. The final batch of four samples consisted of: one inch diameter MgF2 mirror, control 1200-ID-FL3; one inch diameter neat resin, PMR-15, AO171-IV-55, half exposed and half unexposed; one inch diameter chromic acid anodized, EOIM-3 120-47 aluminum disc; and AO-exposed and unexposed samples of fullerene extract material in powdered form, pressed into In foil for analysis. Chemical analyses of the surfaces were performed by the surface analysis by laser ionization (SALI) method. The analyses emphasize surface contamination or general organic composition. SALI uses nonselective photoionization of sputtered or desorbed atoms and molecules above but close (approximately one mm) to the surface, followed by time-of-flight (TOF) mass spectrometry. In these studies, we used laser-induced desorption by 5-ns pulse-width 355-nm light (10-100 mJ/sq cm) and single-photon ionization (SPI) by coherent 118-nm radiation (at approximately 5 x 10(exp 5) W/sq cm). SPI was chosen primarily for its ability to obtain molecular information, whereas multiphoton ionization (not used in the present studies) is intended primarily for elemental and small molecule information. In addition to these four samples, the Au mirror (EOIM-3 200-11, sample four) was depth profiled again. Argon ion sputtering was used together with photoionization with intense 355-nm radiation (35-ps pulsewidths). Depth profiles are similar to those reported earlier, showing reproducibility. No chromium was found in the sample above noise level; its presence could at most be at the trace level. Somewhat more Ni appears to be present in the Au layer in the unexposed side, indicating thermal diffusion without chemical enhancement. The result of the presence of oxygen is apparently to tie-up/draw out the Ni as an oxide at the surface. The exposed region has a brownish tint appearance to the naked eye.

  14. Problems Found Using a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2008-04-01

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion of anthropogenic activity estimates with the relative bias being small compared to the dispersion, indicating that the system would not give false positive indications for an appropriately set decision level. By also measuring environmental air sample filters simultaneously with electroplated alpha filters, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations from calibrated values indicating that the system would give false negative indications. Use of the current algorithm is, therefore, not recommended for general assay applications. Use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve-fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha activities on air sample filters (not due to radon progeny) around the 200 disintegrations per minute level.

  15. Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2009-01-23

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level.

  16. Determination of reduced sulfur compounds in air samples for the monitoring of malodor caused by landfills.

    PubMed

    Borrás, Esther; Tortajada-Genaro, Luis Antonio; Muñoz, Amalia

    2016-02-01

    A reliable method for determining malodorous reduced sulfur compounds (RSC) in atmospheric samples has been developed. The method uses an activated coconut solid-phase sorbent for active sampling, hexane as desorption solvent, and gas chromatography-mass spectrometry (GC-MS) technique for specific and sensitive separation-detection. The compounds analyzed were hydrogen sulfide, ethyl mercaptan, dimethyl sulfide, carbon disulfide, butyl mercaptan and dimethyl disulfide. Recovery efficiency varied between 75% and 97% and no detectable losses were observed during storage at -20°C. Satisfactory analytical parameters were reported, such as good linearity (r(2)>0.98), low detection limits (0.6-59 pg m(-3)), adequate repeatability (9%) and reproducibility (17%), and fast GC-MS analysis (<6.5 min). The accurate determination of RSCs, free of interferences from atmospheric components, such as ozone or water was demonstrated. The method has been applied to analyze the composition of environmental air close to three landfills processing urban and industrial solid wastes. The results indicated that hydrogen sulfide and ethyl mercaptan were the main molecules responsible of malodor phenomenon in the study areas. PMID:26653474

  17. Sampling considerations for modal analysis with damping

    NASA Astrophysics Data System (ADS)

    Park, Jae Young; Wakin, Michael B.; Gilbert, Anna C.

    2015-03-01

    Structural health monitoring (SHM) systems are critical for monitoring aging infrastructure (such as buildings or bridges) in a cost-effective manner. Wireless sensor networks that sample vibration data over time are particularly appealing for SHM applications due to their flexibility and low cost. However, in order to extend the battery life of wireless sensor nodes, it is essential to minimize the amount of vibration data these sensors must collect and transmit. In recent work, we have studied the performance of the Singular Value Decomposition (SVD) applied to the collection of data and provided new finite sample analysis characterizing conditions under which this simple technique{also known as the Proper Orthogonal Decomposition (POD){can correctly estimate the mode shapes of the structure. Specifically, we provided theoretical guarantees on the number and duration of samples required in order to estimate a structure's mode shapes to a desired level of accuracy. In that previous work, however, we considered simplified Multiple-Degree-Of-Freedom (MDOF) systems with no damping. In this paper we consider MDOF systems with proportional damping and show that, with sufficiently light damping, the POD can continue to provide accurate estimates of a structure's mode shapes. We support our discussion with new analytical insight and experimental demonstrations. In particular, we study the tradeoffs between the level of damping, the sampling rate and duration, and the accuracy to which the structure's mode shapes can be estimated.

  18. Transuranic waste characterization sampling and analysis plan

    SciTech Connect

    1994-12-31

    Los Alamos National Laboratory (the Laboratory) is located approximately 25 miles northwest of Santa Fe, New Mexico, situated on the Pajarito Plateau. Technical Area 54 (TA-54), one of the Laboratory`s many technical areas, is a radioactive and hazardous waste management and disposal area located within the Laboratory`s boundaries. The purpose of this transuranic waste characterization, sampling, and analysis plan (CSAP) is to provide a methodology for identifying, characterizing, and sampling approximately 25,000 containers of transuranic waste stored at Pads 1, 2, and 4, Dome 48, and the Fiberglass Reinforced Plywood Box Dome at TA-54, Area G, of the Laboratory. Transuranic waste currently stored at Area G was generated primarily from research and development activities, processing and recovery operations, and decontamination and decommissioning projects. This document was created to facilitate compliance with several regulatory requirements and program drivers that are relevant to waste management at the Laboratory, including concerns of the New Mexico Environment Department.

  19. Passive dosimeters for nitrogen dioxide in personal/indoor air sampling: A review

    PubMed Central

    Yu, Chang Ho; Morandi, Maria T.; Weisel, Clifford P.

    2015-01-01

    Accurate measurement of nitrogen dioxide concentrations in both outdoor and indoor environments, including personal exposures, is a fundamental step for linking atmospheric nitrogen dioxide levels to potential health and ecological effects. The measurement has been conducted generally in two ways: active (pumped) sampling and passive (diffusive) sampling. Diffusion samplers, initially developed and used for workplace air monitoring, have been found to be useful and cost-effective alternatives to conventional pumped samplers for monitoring ambient, indoor and personal exposures at the lower concentrations found in environmental settings. Since the 1970s, passive samplers have been deployed for ambient air monitoring in urban and rural sites, and to determine personal and indoor exposure to NO2. This article reviews the development of NO2 passive samplers, the sampling characteristics of passive samplers currently available, and their application in ambient and indoor air monitoring and personal exposure studies. The limitations and advantages of the various passive sampler geometries (i.e., tube, badge, and radial type) are also discussed. This review provides researchers and risk assessors with practical information about NO2 passive samplers, especially useful when designing field sampling strategies for exposure and indoor/outdoor air sampling. PMID:18446185

  20. Qualitative multiplatform microanalysis of individual heterogeneous atmospheric particles from high-volume air samples.

    PubMed

    Conny, Joseph M; Collins, Sean M; Herzing, Andrew A

    2014-10-01

    High-resolution microscopic analysis of individual atmospheric particles can be difficult, because the filters upon which particles are captured are often not suitable as substrates for microscopic analysis. Described here is a multiplatform approach for microscopically assessing chemical and optical properties of individual heterogeneous urban dust particles captured on fibrous filters during high-volume air sampling. First, particles embedded in fibrous filters are transferred to polished silicon or germanium wafers with electrostatically assisted high-speed centrifugation. Particles are clustered in an array of deposit areas, which allows for easily locating the same particle with different microscopy instruments. Second, particles with light-absorbing and/or light-scattering behavior are identified for further study from bright-field and dark-field light-microscopy modes, respectively. Third, particles identified from light microscopy are compositionally mapped at high definition with field-emission scanning electron microscopy and energy-dispersive X-ray spectroscopy. Fourth, compositionally mapped particles are further analyzed with focused ion-beam (FIB) tomography, whereby a series of thin slices from a particle are imaged, and the resulting image stack is used to construct a three-dimensional model of the particle. Finally, particle chemistry is assessed over two distinct regions of a thin FIB slice of a particle with energy-filtered transmission electron microscopy (TEM) and electron energy-loss spectroscopy associated with scanning transmission electron microscopy (STEM). PMID:25220253

  1. Multivariate analysis comparing microbial air content of an air-conditioned building and a naturally ventilated building over one year

    NASA Astrophysics Data System (ADS)

    Parat, Sylvie; Perdrix, Alain; Fricker-Hidalgo, Hélène; Saude, Isabelle; Grillot, Renee; Baconnier, Pierre

    Heating, ventilation and air-conditioning (HVAC) may be responsible for the production and spread of airborne microorganisms in office buildings. In order to compare airborne microbiological flora in an air-conditioned building with that in a naturally ventilated building, eight sets of measurements were made over a 1-year period. Concurrently with other environmental measurements, air samples were collected in each building, from three offices and from the outdoor air, using the Andersen single-stage sampler. Three different media were used to culture fungi, staphylococci and mesophilic bacteria. Multivariate analysis revealed a group of offices more contaminated than others, and a marked seasonal variation in fungal concentrations. A comparison of mean levels of microorganisms measured in the two buildings showed that the air microbial content was significantly higher and more variable in the naturally ventilated building than in the air-conditioned building. Moreover, in the naturally ventilated building, the interior fungal content was strongly dependent on the outdoor content, while in the air-conditioned building fungal concentrations remained constant despite significant variations measured outside. This was confirmed by a statistical comparison of the correlation coefficients between indoor and outdoor concentrations. No difference was observed regarding gaseous pollutants and temperature, but relative humidity was significantly higher in the air-conditioned building. The effect of HVAC was to prevent the intake of outdoor particles and to dilute the indoor concentrations. These results are consistent with the presence of high-efficiency filters and a steam humidifier in the HVAC system under study.

  2. Solubility testing of actinides on breathing-zone and area air samples

    SciTech Connect

    Metzger, R.L.; Jessop, B.H.; McDowell, B.L.

    1996-02-01

    A solubility testing method for several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALS{reg_sign}) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of U{sub 3}O{sub 8}. Profiles developed for U{sub 3}O{sub 8} samples show good agreement with in vitro and in vivo tests performed by other investigators on samples from the same uranium mills.

  3. Europlanet Research Infrastructure: Planetary Sample Analysis Facilities

    NASA Astrophysics Data System (ADS)

    Cloquet, C.; Mason, N. J.; Davies, G. R.; Marty, B.

    2008-09-01

    EuroPlanet The Europlanet Research Infrastructure consortium funded under FP7 aims to provide the EU Planetary Science community greater access for to research infrastructure. A series of networking and outreach initiatives will be complimented by joint research activities and the formation of three Trans National Access distributed service laboratories (TNA's) to provide a unique and comprehensive set of analogue field sites, laboratory simulation facilities, and extraterrestrial sample analysis tools. Here we report on the infrastructure that comprises the third TNA: Planetary Sample Analysis Facilities. The modular infrastructure represents a major commitment of analytical instrumentation by three institutes and together forms a state-of-the-art analytical facility of unprecedented breadth. These centres perform research in the fields of geochemistry and cosmochemistry, studying fluids and rocks in order to better understand the keys cof the universe. Europlanet Research Infrastructure Facilities: Ion Probe facilities at CRPG and OU The Cameca 1270 Ion microprobe is a CNRS-INSU national facility. About a third of the useful analytical time of the ion probe (about 3 months each year) is allocated to the national community. French scientists have to submit their projects to a national committee for selection. The selected projects are allocated time in the following 6 months twice a year. About 15 to 20 projects are run each year. There are only two such instruments in Europe, with cosmochemistry only performed at CRPG. Different analyses can be performed on a routine basis, such as U-Pb dating on Zircon, Monazite or Pechblende, Li, B, C, O, Si isotopic ratios determination on different matrix, 26Al, 60Fe extinct radioactivity ages, light and trace elements contents . The NanoSIMS 50L - producing element or isotope maps with a spatial resolution down to ≈50nm. This is one of the cornerstone facilities of UKCAN, with 75% of available instrument time funded and

  4. Genotoxicity, inflammation and physico-chemical properties of fine particle samples from an incineration energy plant and urban air.

    PubMed

    Sharma, Anoop Kumar; Jensen, Keld Alstrup; Rank, Jette; White, Paul A; Lundstedt, Staffan; Gagne, Remi; Jacobsen, Nicklas R; Kristiansen, Jesper; Vogel, Ulla; Wallin, Håkan

    2007-10-01

    Airborne particulate matter (PM) was sampled by use of an electrostatic sampler in an oven hall and a receiving hall in a waste-incineration energy plant, and from urban air in a heavy-traffic street and from background air in Copenhagen. PM was sampled for 1-2 weeks, four samples at each site. The samples were extracted and examined for mutagenicity in Salmonella typhimurium strains TA98, YG1041 and YG5161, for content of inorganic elements and for the presence of eight polycyclic aromatic hydrocarbons. The induction of IL-6 and IL-8 mRNA expression and the presence of DNA damage - tested by the comet assay - were determined after 24-h incubations with human A549 lung epithelial cells. The PM(2.5) concentration was about twofold greater in the oven hall than in the receiving hall. The particle size distribution in the receiving hall was similar to that in street air (maximum mode at about 25nm), but the distribution was completely different in the oven hall (maximum mode at about 150nm). Also chemically, the samples from the oven hall were highly different from the other samples. PM extracts from the receiving hall, street and background air were more mutagenic than the PM extracts from the oven hall. PM from all four sites caused similar levels of DNA damage in A549 cells; only the oven hall samples gave results that were statistically significantly different from those obtained with street-air samples. The receiving hall and the urban air samples were similarly inflammatory (relative IL-8 mRNA expression), whereas the oven hall did not cause a statistically significant increase in IL-8 mRNA expression. A principal component analysis separated the oven hall and the receiving hall by the first principal component. These two sites were separated from street and background air with the second principal component. Several clusters of constituents were identified. One cluster consisted of all the polycyclic aromatic hydrocarbons (PAH), several groups of metals and one

  5. Air Sampling System for use in monitoring viable and non-viable particulate air quality under dynamic operating conditions of blow/fill/seal processing.

    PubMed

    Probert, Steve; Sinclair, Colin S; Tallentire, Alan

    2002-01-01

    An Air Sampling Link (ASL), employed in conjunction with an Air Sampling Device (ASD) or a laser particle counter, has been developed for sampling flowing air for viable and non-viable particulate analyses. Typically, the ASL could be used to sample filtered air supplied to an air shower of a Blow/Fill/Seal machine operating in the dynamic state. The ASL allows sample volumes of air to be taken from flowing air without significant loss from the sample flow of airborne particles possessing aerodynamic sizes relevant to those found in practice. The link has no moving parts, is steam sterilizable in-situ, and allows for the taking of continuous samples of air without the need for intervention into the 'critical zone' of the filling machine. This article describes (i) the design criteria for the ASL and the ASD, (ii) the rationale underlying the concept of the ASL design, (iii) the collection performance of the ASL against that of a conventional sampling arrangement, and (iv) a functionality assessment of the ASL-based sampling system installed on a Rommelag style 305 B/F/S machine over a seven week period. PMID:12404722

  6. Development and calibration of real-time PCR for quantification of airborne microorganisms in air samples

    NASA Astrophysics Data System (ADS)

    An, Hey Reoun; Mainelis, Gediminas; White, Lori

    This manuscript describes the coupling of bioaerosol collection and the use of real-time PCR (RT-PCR) to quantify the airborne bacteria. The quantity of collected bacteria determined by RT-PCR is compared with conventional quantification techniques, such as culturing, microscopy and airborne microorganism counting by using optical particle counter (OPC). Our data show that an experimental approach used to develop standard curves for use with RT-PCR is critical for accurate sample quantification. Using universal primers we generated 12 different standard curves which were used to quantify model organism Escherichia coli (Migula) Catellani from air samples. Standard curves prepared using a traditional approach, where serially diluted genomic DNA extracted from pure cultured bacteria were used in PCR reaction as a template DNA yielded significant underestimation of sample quantities compared to airborne microorganism concentration as measured by an OPC. The underestimation was especially pronounced when standard curves were built using colony forming units (CFUs). In contrast, the estimate of cell concentration in an air sample by RT-PCR was more accurate (˜60% compared to the airborne microorganism concentration) when the standard curve was built using aerosolized E. coli. The accuracy improved even further (˜100%) when air samples used to build the standard curves were diluted first, then the DNA extracted from each dilution was amplified by the RT-PCR—to mimic the handling of air samples with unknown and possibly low concentration. Therefore, our data show that standard curves used for quantification by RT-PCR needs to be prepared using the same environmental matrix and procedures as handling of the environmental sample in question. Reliance on the standard curves generated with cultured bacterial suspension (a traditional approach) may lead to substantial underestimation of microorganism quantities in environmental samples.

  7. The effect of compressed air foam on the detection of hydrocarbon fuels in fire debris samples.

    PubMed

    Coulson, S A; Morgan-Smith, R K; Noble, D

    2000-01-01

    In 1998/99 the New Zealand Fire Service implemented compressed air foam delivery systems for the suppression of fires in rural areas. This study investigated whether the introduction of the foam to the seat of the fire created any problems in subsequent analyses of fire debris samples. No significant interferences from the foam were found when the samples were analysed by direct headspace using activated carbon strips. The only foam component detected was limonene. PMID:11094822

  8. Spacelab J air filter debris analysis

    NASA Technical Reports Server (NTRS)

    Obenhuber, Donald C.

    1993-01-01

    Filter debris from the Spacelab module SLJ of STS-49 was analyzed for microbial contamination. Debris for cabin and avionics filters was collected by Kennedy Space Center personnel on 1 Oct. 1992, approximately 5 days postflight. The concentration of microorganisms found was similar to previous Spacelab missions averaging 7.4E+4 CFU/mL for avionics filter debris and 4.5E+6 CFU/mL for the cabin filter debris. A similar diversity of bacterial types was found in the two filters. Of the 13 different bacterial types identified from the cabin and avionics samples, 6 were common to both filters. The overall analysis of these samples as compared to those of previous missions shows no significant differences.

  9. Application of parabolic reflector on Raman analysis of gas samples

    NASA Astrophysics Data System (ADS)

    Yu, Anlan; Zuo, Duluo; Gao, Jun; Li, Bin; Wang, Xingbing

    2016-05-01

    Studies on the application of a parabolic reflector in spontaneous Raman scattering for low background Raman analysis of gas samples are reported. As an effective signal enhancing sample cell, photonic bandgap fiber (HC-PBF) or metallined capillary normally result in a strong continuous background in spectra caused by the strong Raman/fluorescence signal from the silica wall and the polymer protective film. In order to obtain enhanced signal with low background, a specially designed sample cell with double-pass and large collecting solid angle constructed by a parabolic reflector and a planar reflector was applied, of which the optical surfaces had been processed by diamond turning and coated by silver film and protective film of high-purity alumina. The influences of optical structure, polarization characteristic, collecting solid-angle and collecting efficiency of the sample cell on light propagation and signal enhancement were studied. A Raman spectrum of ambient air with signal to background ratio of 94 was acquired with an exposure time of 1 sec by an imaging spectrograph. Besides, the 3σ limits of detection (LOD) of 7 ppm for H2, 8 ppm for CO2 and 12 ppm for CO were also obtained. The sample cell mainly based on parabolic reflector will be helpful for compact and high-sensitive Raman system.

  10. Deuterium content of H2 measured on air samples from the CARIBIC project

    NASA Astrophysics Data System (ADS)

    Batenburg, A. M.; Schuck, T.; Brenninkmeijer, C. A. M.; Röckmann, T.

    2009-04-01

    H2 is present in the atmosphere at levels of ~500 ppb; its largest sources are the oxidation of methane and other hydrocarbons and combustion processes. In the coming decades, H2 levels are expected to rise due to use of hydrogen as an energy carrier. This may affect methane lifetimes and stratospheric ozone depletion. Unfortunately, large uncertainties still exist in the global H2budget. The different sources and sinks of H2 have very distinct isotopic signatures and fractionation coefficients, respectively. For this reason, measurements of isotopic composition are a promising tool to gain insight into H2 source and sink processes and to constrain the terms in the global budget. The CARIBIC project uses an automated instrument container on board of a commercial passenger aircraft to carry out in situ measurements of trace gases and aerosols and to collect air samples. The use of a commercial airliner results in samples mostly from the Upper Troposphere-Lower Stratosphere (UTLS) region. Although the UTLS region is considered to be an interesting part of the atmosphere, relatively few measurements have been made there before. The CARIBIC samples are routinely analyzed for various gases, including four important greenhouse gases. In addition, air samples of 15 CARIBIC flights have now been analyzed for molecular hydrogen concentration (H2) and H2 deuterium content (^D-H2) in the isotope laboratory of the Institute of Marine and Atmospheric Research Utrecht (IMAU). A GC-IRMS system (similar to Rhee et al. [2004]) is used to determine the concentration and deuterium content of atmospheric H2 precisely and routinely. This poster will present a selection of the first results. For some flights, samples close to the takeoff and landing region show strong contamination signatures (high H2 concentrations and low ^D-H2 values). With the exclusion of these samples, ^D values correlate negatively with methane concentration, as observed previously by Rahn et al. [2003] and R

  11. Cryogenic separation of oxygen-argon mixture in natural air samples for isotopic and molecular ratios

    NASA Astrophysics Data System (ADS)

    Habeeb Rahman, Keedakkadan; Abe, Osamu

    2014-05-01

    The discovery of mass independent isotope fractionation in oxygen during the formation of ozone in the stratosphere has initiated a wide application in isotope geochemistry field. Separation of oxygen-argon mixture has become the foundation of high precision analysis of Δ17O and δ(O2/Ar) for geochemical applications. Here we present precise and simplified cryogenic separation of argon oxygen mixture from the atmospheric and dissolved air using 30/60 mesh 5A molecular sieve zeolite. A pioneer study of this method was conducted by Thiemens and Meagher in 1984. The column which is made of glass tube contains about 1.1 grams of molecular sieve zeolite and both ends of column was filled with glass wools. The experimental set up was tested for different combination of molecular sieves and slurry temperatures. We found the most efficient condition for the separation was at a column temperature of -103°C. For complete transfer of O2 and Ar mixture usually takes in 15-20 minutes time. The isotopic ratios of oxygen were analyzed using mass spectrometer (Thermo Fischer Delta Plus) relative to reference oxygen-argon mixture at 3V of m/z 32 for both sample and reference side. The signals of m/z 28, 32, and 40 were measured by dynamically to determine oxygen -argon ratio and to check nitrogen contamination. Repeated measurements of atmospheric air yielded a reproducibility (SE n=80) of 0.006, 0.004 and 0.19‰ for δ17O, δ18O and δO2/Ar respectively. The isotopic and molecular fractionation of argon- oxygen mixture during gas adsorption and desorption while using molecular sieve under liquid nitrogen temperature was studied. We have established a linear relationship governing the effect of 13X and 5A molecular sieves on molecular fractionation. And suggested the use of single 1/8" pellet 13X molecular sieve provided a negligible fractionation.

  12. Development of a wireless air pollution sensor package for aerial-sampling of emissions

    EPA Science Inventory

    A new sensor system for mobile and aerial emission sampling was developed for open area pollutant sources, such as prescribed forest burns. The sensor system, termed “Kolibri”, consists of multiple low-cost air quality sensors measuring CO2, CO, samplers for particulate matter wi...

  13. the nature of air flow near the inlets of blunt dust sampling probes

    NASA Astrophysics Data System (ADS)

    Vincent, J. H.; Hutson, D.; Mark, D.

    This paper sets out to describe the nature of air flow near blunt dust samplers in a way which allows a relatively simple assessment of their performances for collecting dust particles. Of particular importance is the shape of the limiting stream surface which divides the sampled air from that which passes outside the sampler, and how this is affected by the free-stream air velocity, the sampling flow rate, and the shape of the sampler body. This was investigated for two-dimensional and axially-symmetric sampler systems by means of complementary experiments using electrolytic tank potential flow analogues and a wind tunnel respectively. For extreme conditions the flow of air entering the sampling orifice may be wholly divergent or wholly convergent. For a wide range of intermediate conditions, however, the flow first diverges then converges, exhibiting a so-called "spring onion effect". Whichever of these applies for a particular situation, the flow may be considered to consist of two parts, the outer one dominated by the flow about the sampler body and the inner one dominated by the flow into the sampling orifice. Particle transport in this two-part flow may be assessed using ideas borrowed from thin-walled probe theory.

  14. INTERCOMPARISON OF SAMPLING TECHNIQUES FOR TOXIC ORGANIC COMPOUNDS IN INDOOR AIR

    EPA Science Inventory

    People spend a major fraction of their time indoors, and there is concern over exposure to volatile organic compounds present in indoor air. The study was initiated to compare several VOC sampling techniques in an indoor environment. The techniques which were compared include dis...

  15. Development of a wireless air pollution sensor package for aerial-sampling of emissions

    EPA Science Inventory

    A new sensor system for mobile and aerial emission sampling was developed for open area pollutant sources, such as prescribed forest burns. The sensor system, termed “Kolibri”, consists of multiple low-cost air quality sensors measuring CO2, CO, samplers for particula...

  16. INDOOR AIR SAMPLING AND MUTAGENICITY STUDIES OF EMISSIONS FROM UNVENTED COAL COMBUSTION (JOURNAL VERSION)

    EPA Science Inventory

    The purpose of the study is to develop sampling strategies and bioassay methods for indoor air in homes, the authors developed a medium-volume sampler to collect the <10 - micrometers particulate matter and semivolatile organics, and used high-volume particulate sampler for compa...

  17. COMPARISON OF MOLD CONCENTRATIONS IN INDOOR AND OUTDOOR AIR SAMPLED SIMULTANEOUSLY AND THEN QUANTIFIED BY MSQPCR

    EPA Science Inventory

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of the 36 mold species in indoor and outdoor air samples that were taken simultaneously for 48 hours in and around 17 homes in Cincinnati, Ohio. The total spore concentrations of 353 per m3...

  18. CLEANLINESS OF COMMON AIR SAMPLING SORBENTS FOR APPLICATION TO PHENOLIC COMPOUNDS MEASUREMENT USING SUPERCRITICAL FLUID EXTRACTION

    EPA Science Inventory

    The trace-level measurement of phenolic compounds in the ambient air is complicated by the acidic and polar nature of the compounds especially during recovery from the sampling medium. ecently, supercritical fluid extraction (SFE) has been proposed as an alternative extraction me...

  19. Collecting Samples of Workplace Air. Module 8. Vocational Education Training in Environmental Health Sciences.

    ERIC Educational Resources Information Center

    Consumer Dynamics Inc., Rockville, MD.

    This module, one of 25 on vocational education training for careers in environmental health occupations, contains self-instructional materials on collecting samples of workplace air. Following guidelines for students and instructors and an introduction that explains what the student will learn are three lessons: (1) collecting information about…

  20. Neutron activation analysis of wheat samples.

    PubMed

    Galinha, C; Anawar, H M; Freitas, M C; Pacheco, A M G; Almeida-Silva, M; Coutinho, J; Maçãs, B; Almeida, A S

    2011-11-01

    The deficiency of essential micronutrients and excess of toxic metals in cereals, an important food items for human nutrition, can cause public health risk. Therefore, before their consumption and adoption of soil supplementation, concentrations of essential micronutrients and metals in cereals should be monitored. This study collected soil and two varieties of wheat samples-Triticum aestivum L. (Jordão/bread wheat), and Triticum durum L. (Marialva/durum wheat) from Elvas area, Portugal and analyzed concentrations of As, Cr, Co, Fe, K, Na, Rb and Zn using Instrumental Neutron Activation Analysis (INAA) to focus on the risk of adverse public health issues. The low variability and moderate concentrations of metals in soils indicated a lower significant effect of environmental input on metal concentrations in agricultural soils. The Cr and Fe concentrations in soils that ranged from 93-117 and 26,400-31,300mg/kg, respectively, were relatively high, but Zn concentration was very low (below detection limit <22mg/kg) indicating that soils should be supplemented with Zn during cultivation. The concentrations of metals in roots and straw of both varieties of wheat decreased in the order of K>Fe>Na>Zn>Cr>Rb>As>Co. Concentrations of As, Co and Cr in root, straw and spike of both varieties were higher than the permissible limits with exception of a few samples. The concentrations of Zn in root, straw and spike were relatively low (4-30mg/kg) indicating the deficiency of an essential micronutrient Zn in wheat cultivated in Portugal. The elemental transfer from soil to plant decreases with increasing growth of the plant. The concentrations of various metals in different parts of wheat followed the order: Root>Straw>Spike. A few root, straw and spike samples showed enrichment of metals, but the majority of the samples showed no enrichment. Potassium is enriched in all samples of root, straw and spike for both varieties of wheat. Relatively to the seed used for cultivation, Jord

  1. EMP Attachment 1 DOE-SC PNNL Site Sampling and Analysis Plan

    SciTech Connect

    Meier, Kirsten M.

    2011-11-10

    This Sampling and Analysis Plan (SAP) is written for the radiological environmental air surveillance program for the DOE-SC PNNL Site, Richland Washington. It provides the requirements for planning sampling events, and the requirements imposed on the analytical laboratory analyzing the air samples. The actual air sampling process is in procedure EPRP-AIR-029. The rationale for analyte selection, media, and sampling site location has been vetted through the data quality objectives (DQO) process (Barnett et al. 2010). The results from the DQO process have been reviewed and approved by the Washington State Department of Health. The DQO process (Barnett et al. 2010) identified seven specific radionuclides for analysis along with the need for gross alpha and gross beta radiological analyses. The analytes are {sup 241}Am, {sup 243}Am, {sup 244}Cm, {sup 60}Co, {sup 238}Pu, {sup 239}Pu, and {sup 233}U. The report also determined that air samples for particulates are the only sample matrix required for the monitoring program. These samples are collected on 47-mm glass-fiber filters.

  2. High priority tank sampling and analysis report

    SciTech Connect

    Brown, T.M.

    1998-03-05

    In July 1993, the Defense Nuclear Facilities Safety Board (DNFSB) transmitted Recommendation 93-5 (Conway 1993) to the US Department of Energy (DOE). Recommendation 93-5 noted that there was insufficient tank waste technical information and the pace to obtain it was too slow to ensure that Hanford Site wastes could be safely stored, that associated operations could be conducted safely, and that future disposal data requirements could be met. In May 1996, the DOE issued Revision 1 of the Recommendation 93-5 Implementation Plan (DOE-RL 1996). The Implementation Plan revision presented a modified approach to achieve the original plan`s objectives. The approach concentrated on actions necessary to ensure that wastes can be safely stored, that operations can be safely conducted, and that timely characterization information for the tank waste Disposal Program could be obtained. The Implementation Plan proposed 28 High Priority tanks, which, if sampled and analyzed, were expected to provide information to answer questions regarding safety and disposal issues. The High Priority tank list was originally developed in Section 9.0 of the Tank Waste Characterization Basis (Brown et al. 1995) by integrating the needs of the various safety and disposal programs. The High Priority tank list represents a set of tanks that were expected to provide the highest information return for characterization resources expended. The High Priority tanks were selected for near-term core sampling and were not expected to be the only tanks that would provide meaningful information. Sampling and analysis of non-High Priority tanks also could be used to provide scientific and technical data to confirm assumptions, calibrate models, and measure safety related phenomenological characteristics of the waste. When the sampling and analysis results of the High Priority and other tanks were reviewed, it was expected that a series of questions should be answered allowing key decisions to be made. The first

  3. Whole Air Sampling During NASA's March-April 1999 Pacific Exploratory Expedition (PEM-Tropics B)

    NASA Technical Reports Server (NTRS)

    Blake, Donald R.

    2001-01-01

    University of California, Irvine (UCI) collected more than 4500 samples whole air samples collected over the remote Pacific Ocean during NASA's Global Tropospheric Experiment (GTE) Pacific Exploratory Mission-Tropics B (PEM-Tropics B) in March and early April 1999. Approximately 140 samples during a typical 8-hour DC-8 flight, and 120 canisters for each 8-hour flight aboard the P-3B. These samples were obtained roughly every 3-7 min during horizontal flight legs and 1-3 min during vertical legs. The filled canisters were analyzed in the laboratory at UCI within ten days of collection. The mixing ratios of 58 trace gases comprising hydrocarbons, halocarbons, alkyl nitrates and DMS were reported (and archived) for each sample. Two identical analytical systems sharing the same standards were operated simultaneously around the clock to improve canister turn-around time and to keep our measurement precision optimal. This report presents a summary of the results for sample collected.

  4. Results of a Self-Absorption Study on the Versapor 3000 47-mm Filters for Radioactive Particulate Air Stack Sampling

    SciTech Connect

    Barnett, J. Matthew; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-11-01

    Since the mid-1980s the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor® 3000, 47-mm diameter) used at PNNL for self absorption effects. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Large error is associated with the sample filter analysis comparison and subsequently with the estimation of the absorption factor resulting in an inadequate method to estimate losses from self-absorption in the sample filter. The mass loading on the sample filter as determined after digestion and drying was ~0.08 mg cm-2; however, this value may not represent the total filter mass loading given that there may be undetermined losses associated with the digestion process. While it is difficult to determine how much material is imbedded in the filter, observations from the microscopy analysis indicate that the vast majority of the particles remain on the top of the filter. In comparing the results obtained, the continued use of 0.85 as a conservative correction factor is recommended.

  5. Determination of selected heavy metals in air samples from the northern part of Jordan.

    PubMed

    Gharaibeh, Ahmad A; El-Rjoob, Abdul-Wahab O; Harb, Mohammed K

    2010-01-01

    In this work, the atmospheric concentrations of selected heavy metals including lead (Pb), iron (Fe), cadmium (Cd), copper (Cu), nickel (Ni), manganese (Mn), and zinc (Zn) were measured for two different sampling sites (urban and rural) in the northern part of Jordan (Irbid city). Samples were collected according to a certain schedule for 1 year. High volume air samplers and glass fiber filters were used to collect the samples. Collected samples were digested using a mixture of analytical grade nitric acid and analytical grade hydrochloric acid, and analyzed to evaluate the levels of heavy metals by atomic absorption spectrophotometry. Six heavy metals (Pb, Fe, Cu, Ni, Mn, and Zn) were measured in all samples; the concentrations of Cd and Co were not detected in Irbid atmosphere by atomic absorption spectroscopy. The results were used to determine the levels of heavy metal pollutants in air, possible sources, and to compare the levels of selected heavy metals in the two studied sites. Aerosols from the rural site have lower concentrations for all the metals compared to those from the urban site. The daily and monthly variations of the elements were investigated. All heavy metals in urban and rural sites reached maximum concentrations in June, July, and August. This is consistent with the increased activities leading to particulate matter emission during the summer period. The enrichment factors with respect to earth crust and correlation coefficients of heavy metals were investigated to predict the possible sources of heavy metals in air. PMID:19083108

  6. Chemical reactivities of ambient air samples in three Southern California communities

    PubMed Central

    Eiguren-Fernandez, Arantza; Di Stefano, Emma; Schmitz, Debra A.; Guarieiro, Aline Lefol Nani; Salinas, Erika M.; Nasser, Elina; Froines, John R.; Cho, Arthur K.

    2015-01-01

    The potential adverse health effects of PM2.5 and vapor samples from three communities that neighbor railyards, Commerce (CM), Long Beach (LB), and San Bernardino (SB), were assessed by determination of chemical reactivities attributed to the induction of oxidative stress by air pollutants. The assays used were dithiothreitol (DTT) and dihydrobenzoic acid (DHBA) based procedures for prooxidant content and a glyceraldehyde-3-phosphate dehydrogenase (GAPDH) assay for electrophiles. Prooxidants and electrophiles have been proposed as the reactive chemical species responsible for the induction of oxidative stress by air pollution mixtures. The PM2.5 samples from CM and LB sites showed seasonal differences in reactivities with higher levels in the winter whereas the SB sample differences were reversed. The reactivities in the vapor samples were all very similar, except for the summer SB samples, which contained higher levels of both prooxidants and electrophiles. The results suggest the observed reactivities reflect general geographical differences rather than direct effects of the railyards. Distributional differences in reactivities were also observed with PM2.5 fractions containing most of the prooxidants (74–81%) and the vapor phase most of the electrophiles (82–96%). The high levels of the vapor phase electrophiles and their potential for adverse biological effects point out the importance of the vapor phase in assessing the potential health effects of ambient air. PMID:25947123

  7. Air Cargo Transportation Route Choice Analysis

    NASA Technical Reports Server (NTRS)

    Obashi, Hiroshi; Kim, Tae-Seung; Oum, Tae Hoon

    2003-01-01

    Using a unique feature of air cargo transshipment data in the Northeast Asian region, this paper identifies the critical factors that determine the transshipment route choice. Taking advantage of the variations in the transport characteristics in each origin-destination airports pair, the paper uses a discrete choice model to describe the transshipping route choice decision made by an agent (i.e., freight forwarder, consolidator, and large shipper). The analysis incorporates two major factors, monetary cost (such as line-haul cost and landing fee) and time cost (i.e., aircraft turnaround time, including loading and unloading time, custom clearance time, and expected scheduled delay), along with other controls. The estimation method considers the presence of unobserved attributes, and corrects for resulting endogeneity by use of appropriate instrumental variables. Estimation results find that transshipment volumes are more sensitive to time cost, and that the reduction in aircraft turnaround time by 1 hour would be worth the increase in airport charges by more than $1000. Simulation exercises measures the impacts of alternative policy scenarios for a Korean airport, which has recently declared their intention to be a future regional hub in the Northeast Asian region. The results suggest that reducing aircraft turnaround time at the airport be an effective strategy, rather than subsidizing to reduce airport charges.

  8. Analysis of Returned Comet Nucleus Samples

    NASA Astrophysics Data System (ADS)

    Chang, Sherwood

    1997-12-01

    This volume contains abstracts that have been accepted by the Program Committee for presentation at the Workshop on Analysis of Returned Comet Nucleus Samples, held in Milpitas, California, January 16-18, 1989. Conveners are Sherwood Chang (NASA Ames Research Center) and Larry Nyquist (NASA Johnson Space Center). Program Committee members are Thomas Ahrens (ex-officio; California Institute of Technology), Lou Allamandola (NASA Ames Research Center), David Blake (NASA Ames Research Center), Donald Brownlee (University of Washington, Seattle), Theodore E. Bunch (NASA Ames Research Center), Humberto Campins (Planetary Science Institute), Jeff Cuzzi (NASA Ames Research Center), Eberhard Griin (Max-Plank-Institut fiir Kemphysik), Martha Hanner (Jet Propulsion Laboratory), Alan Harris (Jet Propulsion Laboratory), John Kerrid-e (University of Califomia, Los Angeles), Yves Langevin (University of Paris), Gerhard Schwehm (ESTEC), and Paul Weissman (Jet Propulsion Laboratory). Logistics and administrative support for the workshop were provided by the Lunar and Planetary Institute Projects Office.

  9. Analysis of Returned Comet Nucleus Samples

    NASA Technical Reports Server (NTRS)

    Chang, Sherwood (Compiler)

    1997-01-01

    This volume contains abstracts that have been accepted by the Program Committee for presentation at the Workshop on Analysis of Returned Comet Nucleus Samples, held in Milpitas, California, January 16-18, 1989. Conveners are Sherwood Chang (NASA Ames Research Center) and Larry Nyquist (NASA Johnson Space Center). Program Committee members are Thomas Ahrens (ex-officio; California Institute of Technology), Lou Allamandola (NASA Ames Research Center), David Blake (NASA Ames Research Center), Donald Brownlee (University of Washington, Seattle), Theodore E. Bunch (NASA Ames Research Center), Humberto Campins (Planetary Science Institute), Jeff Cuzzi (NASA Ames Research Center), Eberhard Griin (Max-Plank-Institut fiir Kemphysik), Martha Hanner (Jet Propulsion Laboratory), Alan Harris (Jet Propulsion Laboratory), John Kerrid-e (University of Califomia, Los Angeles), Yves Langevin (University of Paris), Gerhard Schwehm (ESTEC), and Paul Weissman (Jet Propulsion Laboratory). Logistics and administrative support for the workshop were provided by the Lunar and Planetary Institute Projects Office.

  10. Mathematical Estimation of the Level of Microbial Contamination on Spacecraft Surfaces by Volumetric Air Sampling

    PubMed Central

    Oxborrow, G. S.; Roark, A. L.; Fields, N. D.; Puleo, J. R.

    1974-01-01

    Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model. PMID:4151118

  11. Mathematical estimation of the level of microbial contamination on spacecraft surfaces by volumetric air sampling

    NASA Technical Reports Server (NTRS)

    Oxborrow, G. S.; Roark, A. L.; Fields, N. D.; Puleo, J. R.

    1974-01-01

    Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model.

  12. High-throughput liquid-absorption air-sampling apparatus and methods

    SciTech Connect

    2000-07-11

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is < 10 cm of water, usually < 5 cm of water. The sampler's collection efficiency is usually > 20% for vapors or airborne particulates in the 2--3 microns range and > 50% for particles larger than 4 microns. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  13. High-throughput liquid-absorption air-sampling apparatus and methods

    DOEpatents

    Zaromb, Solomon

    2000-01-01

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is <10 cm of water, usually <5 cm of water. The sampler's collection efficiency is usually >20% for vapors or airborne particulates in the 2-3.mu. range and >50% for particles larger than 4.mu.. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  14. Data analysis for steam generator tubing samples

    SciTech Connect

    Dodd, C.V.

    1996-07-01

    The objective of the Improved Eddy-Current ISI for Steam Generators program is to upgrade and validate eddy-current inspections, including probes, instrumentation, and data processing techniques for inservice inspection of new, used, and repaired steam generator tubes; to improve defect detection, classification and characterization as affected by diameter and thickness variations, denting, probe wobble, tube sheet, tube supports, copper and sludge deposits, even when defect types and other variables occur in combination; to transfer this advanced technology to NRC`s mobile NDE laboratory and staff. This report provides a description of the application of advanced eddy-current neural network analysis methods for the detection and evaluation of common steam generator tubing flaws including axial and circumferential outer-diameter stress-corrosion cracking and intergranular attack. The report describes the training of the neural networks on tubing samples with known defects and the subsequent evaluation results for unknown samples. Evaluations were done in the presence of artifacts. Computer programs are given in the appendix.

  15. AIR QUALITY FORECAST DATABASE AND ANALYSIS

    EPA Science Inventory

    In 2003, NOAA and EPA signed a Memorandum of Agreement to collaborate on the design and implementation of a capability to produce daily air quality modeling forecast information for the U.S. NOAA's ETA meteorological model and EPA's Community Multiscale Air Quality (CMAQ) model ...

  16. Apportionment of air pollution sources with directional sampling size segregation and soluble/total elemental determination of air particlates in Hong Kong

    SciTech Connect

    Fung, Y.S.; Cheung, H.K.

    1996-12-31

    With an aim to improve the identification of pollution sources, to enhance the ability to resolve source types and to assist the interpretation of results, a computer controlled sampling station has been developed for directional sampling and size segregation of air particulates collected using a High Volume Sampler running at a flow rate of 40 cfm. A given set of criteria was monitored by the microcomputer to stop sampling during raining and calm period (<0.5 ms{sup -1}), and to start the pump when more than 60% of the wind direction data are within the designated sector. Two size fractions of the particulates were collected (coarse, 3.0-10 um, and fine, M 3.0 um) daily with a net sampling time of 16-24 hours. Elemental analysis was performed on the particulates sampled for their total and soluble contents using FTIR for the PAHs, Capillary Electrophoresis and DC Arc Plasma Emission Spectroscopy for soluble and total anion and cation analysis.

  17. Water and entrapped air redistribution in heterogeneous sand sample: Quantitative neutron imaging of the process

    NASA Astrophysics Data System (ADS)

    Snehota, Michal; Jelinkova, Vladimira; Sobotkova, Martina; Sacha, Jan; Vontobel, Peter; Hovind, Jan

    2015-02-01

    Saturated flow in soil with the occurrence of preferential flow often exhibits temporal changes of saturated hydraulic conductivity even during the time scale of a single infiltration event. These effects, observed in a number of experiments done mainly on heterogeneous soils, are often attributed to the changing distribution of water and air in the sample. We have measured the variation of the flow rates during the steady state stage of the constant head ponded infiltration experiment conducted on a packed sample composed of three different grades of sand. The experiment was monitored by quantitative neutron imaging, which provided information about the spatial distribution of water in the sample. Measurements were taken during (i) the initial stages of infiltration by neutron radiography and (ii) during the steady state flow by neutron tomography. A gradual decrease of the hydraulic conductivity has been observed during the first 4 h of the infiltration event. A series of neutron tomography images taken during the quasi-steady state stage showed the trapping of air bubbles in coarser sand. Furthermore, the water content in the coarse sand decreased even more while the water content in the embedded fine sand blocks gradually increased. The experimental results support the hypothesis that the effect of the gradual hydraulic conductivity decrease is caused by entrapped air redistribution and the build up of bubbles in preferential pathways. The trapped air thus restricts the preferential flow pathways and causes lower hydraulic conductivity.

  18. Volatile organic components of air samples collected from Vertical Launch Missile capsules. Summary report

    SciTech Connect

    Tappan, D.V.; Knight, D.R.; Heyder, E.; Weathersby, P.K.

    1988-09-27

    Gas chromatographic/mass spectroscopic analyses are presented for the volatile organic components found in air samples collected from the inboard vents from Vertical Launch System (VLS) missile capsules aboard a 688 class submarine. Similar analyses were also conducted for a sample of the ship's high pressure air used to fill the missile tubes. A wide variety of organics was detected in the air from the missile capsules; and while no unique components have yet been identified, a significant contribution has been shown to be made by pressure-ventilation of the VLS capsules into the submarine atmosphere which is already heavily laden with volatile organic compounds. The most apparent conclusion from these preliminary analyses is that the mixtures of organic components in the air within VLS missile capsules vary greatly from capsule to capsule (and probably from time to time). Many such samples need to be investigated to provide sufficient information to judge the seriousness of the possibility of venting toxic components into the submarine atmosphere during the maintenance or firing of VLS missiles.

  19. Desiccant Enhanced Evaporative Air Conditioning: Parametric Analysis and Design; Preprint

    SciTech Connect

    Woods, J.; Kozubal, E.

    2012-10-01

    This paper presents a parametric analysis using a numerical model of a new concept in desiccant and evaporative air conditioning. The concept consists of two stages: a liquid desiccant dehumidifier and a dew-point evaporative cooler. Each stage consists of stacked air channel pairs separated by a plastic sheet. In the first stage, a liquid desiccant film removes moisture from the process (supply-side) air through a membrane. An evaporatively-cooled exhaust airstream on the other side of the plastic sheet cools the desiccant. The second-stage indirect evaporative cooler sensibly cools the dried process air. We analyze the tradeoff between device size and energy efficiency. This tradeoff depends strongly on process air channel thicknesses, the ratio of first-stage to second-stage area, and the second-stage exhaust air flow rate. A sensitivity analysis reiterates the importance of the process air boundary layers and suggests a need for increasing airside heat and mass transfer enhancements.

  20. MOLECULAR MARKER ANALYSIS OF DEARS SAMPLES

    EPA Science Inventory

    Source apportionment based on organic molecular markers provides a promising approach for meeting the Detroit Exposure and Aerosol Research Study (DEARS) objective of comparing source contributions between community air monitoring stations and various neighborhoods. Source appor...

  1. (ISEA) MOLECULAR MARKER ANALYSIS OF DEARS SAMPLES

    EPA Science Inventory

    Source apportionment based on organic molecular markers provides a promising approach for meeting the Detroit Exposure and Aerosol Research Study (DEARS) objective of comparing source contributions between community air monitoring stations and various neighborhoods. Source appor...

  2. Soyuz 22 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Jams, John T.

    2010-01-01

    Three mini-grab sample containers (m-GSCs) were returned aboard Soyuz 22 because of concerns that new air pollutants were present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The toxicological assessment of 3 m-GSCs from the ISS is shown in Table 1. The recoveries of the 3 standards (as listed above) from the GSCs averaged 103, 95 and 76%, respectively. Recovery from formaldehyde control badges were 90 and 91%.

  3. Sample Analysis at Mars Instrument Simulator

    NASA Technical Reports Server (NTRS)

    Benna, Mehdi; Nolan, Tom

    2013-01-01

    The Sample Analysis at Mars Instrument Simulator (SAMSIM) is a numerical model dedicated to plan and validate operations of the Sample Analysis at Mars (SAM) instrument on the surface of Mars. The SAM instrument suite, currently operating on the Mars Science Laboratory (MSL), is an analytical laboratory designed to investigate the chemical and isotopic composition of the atmosphere and volatiles extracted from solid samples. SAMSIM was developed using Matlab and Simulink libraries of MathWorks Inc. to provide MSL mission planners with accurate predictions of the instrument electrical, thermal, mechanical, and fluid responses to scripted commands. This tool is a first example of a multi-purpose, full-scale numerical modeling of a flight instrument with the purpose of supplementing or even eliminating entirely the need for a hardware engineer model during instrument development and operation. SAMSIM simulates the complex interactions that occur between the instrument Command and Data Handling unit (C&DH) and all subsystems during the execution of experiment sequences. A typical SAM experiment takes many hours to complete and involves hundreds of components. During the simulation, the electrical, mechanical, thermal, and gas dynamics states of each hardware component are accurately modeled and propagated within the simulation environment at faster than real time. This allows the simulation, in just a few minutes, of experiment sequences that takes many hours to execute on the real instrument. The SAMSIM model is divided into five distinct but interacting modules: software, mechanical, thermal, gas flow, and electrical modules. The software module simulates the instrument C&DH by executing a customized version of the instrument flight software in a Matlab environment. The inputs and outputs to this synthetic C&DH are mapped to virtual sensors and command lines that mimic in their structure and connectivity the layout of the instrument harnesses. This module executes

  4. Organically bound tritium analysis in environmental samples

    SciTech Connect

    Baglan, N.; Cossonnet, C.; Fournier, M.; Momoshima, N.; Ansoborlo, E.

    2015-03-15

    Organically bound tritium (OBT) has become of increased interest within the last decade, with a focus on its behaviour and also its analysis, which are important to assess tritium distribution in the environment. In contrast, there are no certified reference materials and no standard analytical method through the international organization related to OBT. In order to resolve this issue, an OBT international working group was created in May 2012. Over 20 labs from around the world participated and submitted their results for the first intercomparison exercise results on potato (Sep 2013). The samples, specially-prepared potatoes, were provided in March 2013 to each participant. Technical information and results from this first exercise are discussed here for all the labs which have realised the five replicates necessary to allow a reliable statistical treatment. The results are encouraging as the increased number of participating labs did not degrade the observed dispersion of the results for a similar activity level. Therefore, the results do not seem to depend on the analytical procedure used. From this work an optimised procedure can start to be developed to deal with OBT analysis and will guide subsequent planned OBT trials by the international group.

  5. Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling.

    PubMed Central

    Buttner, M P; Stetzenbach, L D

    1993-01-01

    Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments. PMID:8439150

  6. Extent of sample loss on the sampling device and the resulting experimental biases when collecting volatile fatty acids (VFAs) in air using sorbent tubes.

    PubMed

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2013-08-20

    Not all volatile organic compounds (VOCs) are suitable for sampling from air onto sorbent tubes (ST) with subsequent analysis by thermal desorption (TD) with gas chromatography (GC). Some compounds (such as C2 hydrocarbons) are too volatile for quantitative retention by sorbents at ambient temperature, while others are too reactive - either for storage stability on the tubes (post-sampling) or for thermal desorption/GC analysis. Volatile fatty acids (VFAs) are one of the compound groups that present a challenge to sorbent tube sampling. In this study, we evaluated sample losses on the inner wall surface of the sorbent tube sampler. The sorptive losses of five VFA (acetic, propionic, n-butyric, i-valeric, and n-valeric acid) were tested using two types of tubes (stainless steel and quartz), each packed with three sorbent beds arranged in order of sorbent strength from the sampling end of the tube (Tenax TA, Carbopack B, and Carbopack X). It showed significantly higher losses of VFAs in both liquid phase and vapor phase when using stainless steel tube samplers. These losses were also seen if vapor-phase fatty acids were passed through empty stainless steel tubing and increased dramatically with increasing molecular weight, e.g., losses of 33.6% (acetic acid) to 97.5% (n-valeric acid). Similar losses of VFAs were also observed from headspace sampling of cheese products. Considering that stainless steel sampling tubes are still used extensively by many researchers, their replacement with quartz tubes is recommended to reduce systematic biases in collecting VFA samples or in their calibration. PMID:23869450

  7. Air

    MedlinePlus

    ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be polluted indoors and it can ... this chart to see what things cause indoor air pollution and what things cause outdoor air pollution! Indoor ...

  8. Field Air Sampling with SPME for Ranking and Prioritization of Downwind Livestock Odors with MDGC-MS-Olfactometry

    NASA Astrophysics Data System (ADS)

    Koziel, Jacek A.; Cai, Lingshuang; Wright, Donald W.; Hoff, Steven J.

    2009-05-01

    Air sampling and characterization of odorous livestock gases is one of the most challenging analytical tasks. This is due to low concentrations, physicochemical properties, and problems with sample recoveries for typical odorants. Livestock operations emit a very complex mixture of volatile organic compounds and other gases. Many of these gases are odorous. Relatively little is known about the link between specific VOCs/gases and specifically, about the impact of specific odorants downwind from sources. In this research, solid phase microextraction (SPME) was used for field air sampling of odors downwind from swine and beef cattle operations. Sampling time ranged from 20 min to 1 hr. Samples were analyzed using a commercial GC-MS-Olfactometry system. Odor profiling efforts were directed at odorant prioritization with respect to distance from the source. The results indicated the odor downwind was increasingly defined by a smaller number of high priority odorants. These `character defining' odorants appeared to be dominated by compounds of relatively low volatility, high molecular weight and high polarity. In particular, p-cresol alone appeared to carry much of the overall odor impact for swine and beef cattle operations. Of particular interest was the character-defining odor impact of p-cresol as far as 16 km downwind of the nearest beef cattle feedlot. The findings are very relevant to scientists and engineers working on improved air sampling and analysis protocols and on improved technologies for odor abatement. More research evaluating the use of p-cresol and a few other key odorants as a surrogate for the overall odor dispersion modeling is warranted.

  9. A sensitive LC-MS/MS method for measurement of organophosphorus pesticides and their oxygen analogs in air sampling matrices.

    PubMed

    Armstrong, Jenna L; Dills, Russell L; Yu, Jianbo; Yost, Michael G; Fenske, Richard A

    2014-01-01

    A rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed for determination of levels of the organophosphorus (OP) pesticides chlorpyrifos (CPF), azinphos methyl (AZM), and their oxygen analogs chlorpyrifos-oxon (CPF-O) and azinphos methyl-oxon (AZM-O) on common active air sampling matrices. XAD-2 resin and polyurethane foam (PUF) matrices were extracted with acetonitrile containing stable-isotope labeled internal standards (ISTD). Analysis was accomplished in Multiple Reaction Monitoring (MRM) mode, and analytes in unknown samples were identified by retention time (±0.1 min) and qualifier ratio (±30% absolute) as compared to the mean of calibrants. For all compounds, calibration linearity correlation coefficients were ≥0.996. Limits of detection (LOD) ranged from 0.15-1.1 ng/sample for CPF, CPF-O, AZM, and AZM-O on active sampling matrices. Spiked fortification recoveries were 78-113% from XAD-2 active air sampling tubes and 71-108% from PUF active air sampling tubes. Storage stability tests also yielded recoveries ranging from 74-94% after time periods ranging from 2-10 months. The results demonstrate that LC-MS/MS is a sensitive method for determining these compounds from two different matrices at the low concentrations that can result from spray drift and long range transport in non-target areas following agricultural applications. In an inter-laboratory comparison, the limit of quantification (LOQ) for LC-MS/MS was 100 times lower than a typical gas chromatography-mass spectrometry (GC-MS) method. PMID:24328542

  10. Determination of trichloroanisole and trichlorophenol in wineries' ambient air by passive sampling and thermal desorption-gas chromatography coupled to tandem mass spectrometry.

    PubMed

    Camino-Sánchez, F J; Bermúdez-Peinado, R; Zafra-Gómez, A; Ruíz-García, J; Vílchez-Quero, J L

    2015-02-01

    The present paper describes the calibration of selected passive samplers used in the quantitation of trichlorophenol and trichloroanisole in wineries' ambient air, by calculating the corresponding sampling rates. The method is based on passive sampling with sorbent tubes and involves thermal desorption-gas chromatography-triple quadrupole mass spectrometry analysis. Three commercially available sorbents were tested using sampling cartridges with a radial design instead of axial ones. The best results were found for Tenax TA™. Sampling rates (R-values) for the selected sorbents were determined. Passive sampling was also used for accurately determining the amount of compounds present in the air. Adequate correlation coefficients between the mass of the target analytes and exposure time were obtained. The proposed validated method is a useful tool for the early detection of trichloroanisole and its precursor trichlorophenol in wineries' ambient air while avoiding contamination of wine or winery facilities. PMID:25576042

  11. Europlanet Research Infrastructure: Planetary Sample Analysis Facilities

    NASA Astrophysics Data System (ADS)

    Cloquet, C.; Mason, N. J.; Davies, G. R.; Marty, B.

    2008-09-01

    EuroPlanet The Europlanet Research Infrastructure consortium funded under FP7 aims to provide the EU Planetary Science community greater access for to research infrastructure. A series of networking and outreach initiatives will be complimented by joint research activities and the formation of three Trans National Access distributed service laboratories (TNA's) to provide a unique and comprehensive set of analogue field sites, laboratory simulation facilities, and extraterrestrial sample analysis tools. Here we report on the infrastructure that comprises the third TNA: Planetary Sample Analysis Facilities. The modular infrastructure represents a major commitment of analytical instrumentation by three institutes and together forms a state-of-the-art analytical facility of unprecedented breadth. These centres perform research in the fields of geochemistry and cosmochemistry, studying fluids and rocks in order to better understand the keys cof the universe. Europlanet Research Infrastructure Facilities: Ion Probe facilities at CRPG and OU The Cameca 1270 Ion microprobe is a CNRS-INSU national facility. About a third of the useful analytical time of the ion probe (about 3 months each year) is allocated to the national community. French scientists have to submit their projects to a national committee for selection. The selected projects are allocated time in the following 6 months twice a year. About 15 to 20 projects are run each year. There are only two such instruments in Europe, with cosmochemistry only performed at CRPG. Different analyses can be performed on a routine basis, such as U-Pb dating on Zircon, Monazite or Pechblende, Li, B, C, O, Si isotopic ratios determination on different matrix, 26Al, 60Fe extinct radioactivity ages, light and trace elements contents . The NanoSIMS 50L - producing element or isotope maps with a spatial resolution down to ≈50nm. This is one of the cornerstone facilities of UKCAN, with 75% of available instrument time funded and

  12. Sampling and analysis of natural gas trace constituents

    SciTech Connect

    Attari, A.; Chao, S.

    1993-09-01

    Major and minor components of natural gas are routinely analyzed by gas chromatography (GC), using a thermal conductivity (TC). The best results obtained by these methods can report no better than 0.01 mole percent of each measured component. Even the extended method of analysis by flame ionization detector (FID) can only improve on the detection limit of hydrocarbons. The gas industry needs better information on all trace constituents of natural gas, whether native or inadvertently added during gas processing that may adversely influence the operation of equipment or the safety of the consumer. The presence of arsenic and mercury in some gas deposits have now been documented in international literature as causing not only human toxicity but also damaging to the field equipment. Yet, no standard methods of sampling and analysis exist to provide this much needed information. In this paper the authors report the results of a three-year program to develop an extensive array of sampling and analysis methods for speciation and measurement of trace constituents of natural gas. A cryogenic sampler operating at near 200 K ({minus}99 F) and at pipeline pressures up to 12.4 {times} 10{sup 6}Pa (1800 psig) has been developed to preconcentrate and recover all trace constituents with boiling points above butanes. Specific analytical methods have been developed for speciating and measurement of many trace components (corresponding to US EPA air toxics) by GC-AED and GC-MS, and for determining various target compounds by other techniques. Moisture, oxygen and sulfur contents are measured on site using dedicated field instruments. Arsenic, mercury and radon are sampled by specific solid sorbents for subsequent laboratory analysis.

  13. An Inexpensive Autosampler to Maximize Throughput for an Ion Source that Samples Surfaces in Open Air

    EPA Science Inventory

    An autosampler was built to pull cotton swab heads mounted into a 3-foot long, square Al rod in ambient air through the He ionizing beam of a Direct Analysis in Real Time (DART) ion source interfaced to an orthogonal acceleration, time-of-flight mass spectrometer. The cost of th...

  14. Solubility testing of actinides on breathing-zone and area air samples

    NASA Astrophysics Data System (ADS)

    Metzger, Robert Lawrence

    The solubility of inhaled radionuclides in the human lung is an important characteristic of the compounds needed to perform internal dosimetry assessments for exposed workers. A solubility testing method for uranium and several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALSsp°ler ) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of Usb3Osb8. This makes it possible to characterize solubility profiles in every section of operating facilities where airborne nuclides are found using common breathing zone air samples. The new method was evaluated by analyzing uranium compounds from two uranium mills whose product had been previously analyzed by in vitro solubility testing in the laboratory and in vivo solubility testing in rodents. The new technique compared well with the in vivo rodent solubility profiles. The method was then used to evaluate the solubility profiles in all process sections of an operating in situ uranium plant using breathing zone and area air samples collected during routine

  15. Continuous monitoring of polychlorinated biphenyls in air using direct sampling APCI/ITMS

    NASA Astrophysics Data System (ADS)

    Yamada, Masuyoshi; Suga, Masao; Waki, Izumi; Sakamoto, Masami; Morita, Masatoshi

    2005-06-01

    We report a continuous monitoring system of polychlorinated biphenyls (PCBs) in air, which uses direct sampling atmospheric pressure chemical ionization (APCI)/ion trap mass spectrometry (ITMS). In APCI, humidity in the atmosphere, which fluctuates from 0 to 10 vol.%, influences PCB sensitivity. In dry air (0.5% humidity), the detection limits of Di- to Hp-chlorinated biphenyls (CB) are 0.01-0.44 [mu]g/Nm3 ([mu]g/m3 at normal condition) with time resolution of 1 min, whereas the sensitivity decreases to less than 1/10 when water vapor concentration is 10 vol.%. The sensitivity decrease is calibrated in real-time using an internal standard, trichlorophenol. In order to obtain the calibration accuracy of +/-30%, we dilute the sample gas by dry air, decreasing the water vapor concentration below 1%. We applied the monitor to measure Di- to Hp-CB in ventilation air from a PCB decomposition plant. The monitored PCB concentration levels agreed well with that by high-resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS).

  16. The beryllium quandary: will the lower exposure limits spur new developments in sampling and analysis?

    SciTech Connect

    Brisson, Michael

    2013-06-03

    At the time this article was written, new rulemakings were under consideration at OSHA and the U.S. Department of Energy (DOE) that would propose changes to occupational exposure limits for beryllium. Given these developments, it’s a good time to review the tools and methods available to IHs for assessing beryllium air and surface contamination in the workplace—what’s new and different, and what’s tried and true. The article discusses limit values and action levels for beryllium, problematic aspects of beryllium air sampling, sample preparation, sample analysis, and data evaluation.

  17. Laboratory validation and field verification of a new passive air monitoring badge for sampling ethylene oxide in air.

    PubMed

    Kring, E V; Damrell, D J; Basilio, A N; McGibney, P D; Douglas, J J; Henry, T J; Ansul, G R

    1984-10-01

    A new diffusion colorimetric air monitoring badge for sampling ethylene oxide is described. The Du Pont Pro-Tek C-70 badge has been laboratory validated over the range of 4-375 ppm-hours (0.5-47 ppm on an 8-hour TWA) using standard spectrophotometer readout in 1 centimeter (10 mm) cells. The lower range can be extended to 2 ppm-hours (0.25 ppm) by using 4 cm (40 mm) cells. The badge has an overall sampling and analytical method accuracy of +/- 13.5%. It meets NIOSH accuracy criteria and has a mean coefficient of variation CVT = 0.059. The badge has no temperature, pressure, relative humidity or face velocity effects over practical ranges. The response time is adequate to sample peak concentrations over short time periods. The badge may be used to determine ambient formaldehyde levels if suspected to be present along with ethylene oxide. Badges are shown to agree very well with the industry accepted and proposed ASTM pump/charcoal tube method in three extensive plant field tests. Badges were more precise than the charcoal tube/pump method in all field tests conducted. PMID:6496316

  18. Methods for polynuclear aromatic hydrocarbon determination in air samples using polar-bonded phase HPLC and GC-MS with application to oil refinery samples

    SciTech Connect

    Karlesky, K.L.

    1985-01-01

    Particle samples were collected using high volume air samplers fitted with glass fiber filters or with a cascade impactor containing paper filters. They were then cleaned using either extraction with dimethylsulfoxide and pentane or utilizing a small cartridge containing a diamine polar-bonded phase material, the second method being more effective. Vapor phase PAH were sampled using an apparatus designed in the laboratory. After collection, the resins were desorbed with solvent and the PAH content was determined. The suitability of the resins decrease in the following order: Amberlite XAD-2, Chromosorb 105, Tenax GC, coconut charcoal, and Ambesorb XE-348. High performance liquid chromatography (HPLC) was used to determine the behavior of PAH in the normal and reversed phase on polar-bonded phases containing amine, diamine, and pyrrolidone substrates. Results support the proposed mechanism in the normal phase and indicate that both a partitioning and liquid-solid adsorption mechanism takes place in the reversed phase depending upon the mobile phase. Occasionally, these polar-bonded phases can be deactivated by the formation of amine-carbonyl complexes from polar aldehydes or ketones in the solvent or sample. Deactivation can be reversed by flushing with water to hydrolyze the Schiff's base imine back to the amine. Gas chromatography-mass spectroscopy (GC-MS) was used to analyze air samples from oil refineries in Port Arthur, collected over a period of three years. The analytical procedures are applied to the collected samples to determine if they contain detectable amounts of PAH. The GC-MS analysis was adequate for this study but the use of SIM detection is preferred because of the greater sensitivity for PAH.

  19. STS-65 Commander Cabana and PLC Hieb take air sample at IML-2 Rack 7 NIZEMI

    NASA Technical Reports Server (NTRS)

    1994-01-01

    STS-65 Commander Robert D. Cabana (right) and Payload Commander (PLC) Richard J. Hieb take an air sample inside the International Microgravity Laboratory 2 (IML-2) spacelab science module. The two crewmembers are in front of Rack 7 which contains the large isothermal furnace (LIF) and slow rotating centrifuge microscope (NIZEMI). The photo was among the first group released by NASA following the two-week IML-2 mission aboard the Space Shuttle Columbia, Orbiter Vehicle (OV) 102.

  20. Organic toxicants in air and precipitation samples from the Lake Michigan area

    SciTech Connect

    Harlin, K.S.; Sweet, C.W.; Gatz, D.F.

    1995-12-31

    Measurements of PCBs, organochlorine insecticides, PAHs, and atrazine were made in air and precipitation samples collected at regionally-representative locations near Lake Michigan from 1992-1995. The purpose of these measurements was to provide information needed to estimate the atmospheric deposition of organic toxicants to Lake Michigan. Twenty-four hour samples of airborne particles and vapor were collected at 12-day intervals on quartz fiber filters and XAD-2 resin vapor traps using modified high volume sampleers. Twenty-eight day precipitation samples were collected using wet-only samplers with stainless steel sampling surfaces and heated enclosure containing an XAD-2 resin adsorption column. Samples were Soxhlet extracted for 24 hours with hexane:acetone (1:1), and concentrated by rotary evaporation. Interferences were removed and the samples separated into analyte groups by silica gel chromatography. Four fractions were collected for GC-ECD and GC-Ion Trap MS analyses. Ten pesticides, 101 PCB congeners, 18 PAHs, and atrazine were measured in all samples. Quality assurance was maintained by including field duplicate samples, field blanks, alboratory matrix spikes, laboratory matrix blanks, and laboratory surrogate spikes in the sampling/analytical protocols. Preliminary results from urban and remote sites show geographical variations in the concentrations of some toxicants due to contributions from local sources. For all sites the total PCB levels are higher in the vapor phase than the particulate phase and show strong seasonal variations. Seasonal variations were also observed for several pesticides.

  1. A comparison of portable XRF and ICP-OES analysis for lead on air filter samples from a lead ore concentrator mill and a lead-acid battery recycler.

    PubMed

    Harper, Martin; Pacolay, Bruce; Hintz, Patrick; Andrew, Michael E

    2006-03-01

    Personal and area samples for airborne lead were taken at a lead mine concentrator mill, and at a lead-acid battery recycler. Lead is mined as its sulfidic ore, galena, which is often associated with zinc and silver. The ore typically is concentrated, and partially separated, on site by crushing and differential froth flotation of the ore minerals before being sent to a primary smelter. Besides lead, zinc and iron are also present in the airborne dusts, together with insignificant levels of copper and silver, and, in one area, manganese. The disposal of used lead-acid batteries presents environmental issues, and is also a waste of recoverable materials. Recycling operations allow for the recovery of lead, which can then be sold back to battery manufacturers to form a closed loop. At the recycling facility lead is the chief airborne metal, together with minor antimony and tin, but several other metals are generally present in much smaller quantities, including copper, chromium, manganese and cadmium. Samplers used in these studies included the closed-face 37 mm filter cassette (the current US standard method for lead sampling), the 37 mm GSP or "cone" sampler, the 25 mm Institute of Occupational Medicine (IOM) inhalable sampler, the 25 mm Button sampler, and the open-face 25 mm cassette. Mixed cellulose-ester filters were used in all samplers. The filters were analyzed after sampling for their content of the various metals, particularly lead, that could be analyzed by the specific portable X-ray fluorescence (XRF) analyzer under study, and then were extracted with acid and analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES). The 25 mm filters were analyzed using a single XRF reading, while three readings on different parts of the filter were taken from the 37 mm filters. For lead at the mine concentrate mill, all five samplers gave good correlations (r2 > 0.96) between the two analytical methods over the entire range of found lead mass

  2. HIGH VOLUME INJECTION FOR GCMS ANALYSIS OF PARTICULATE ORGANIC SPECIES IN AMBIENT AIR

    EPA Science Inventory

    Detection of organic species in ambient particulate matter typically requires large air sample volumes, frequently achieved by grouping samples into monthly composites. Decreasing the volume of air sample required would allow shorter collection times and more convenient sample c...

  3. Isotopic air sampling in a tallgrass prairie to partition net ecosystem CO2 exchange

    NASA Astrophysics Data System (ADS)

    Lai, Chun-Ta; Schauer, Andrew J.; Owensby, Clenton; Ham, Jay M.; Ehleringer, James R.

    2003-09-01

    Stable isotope ratios of various ecosystem components and net ecosystem exchange (NEE) CO2 fluxes were measured in a C3-C4 mixture tallgrass prairie near Manhattan, Kansas. The July 2002 study period was chosen because of contrasting soil moisture contents, which allowed us to address the effects of drought on photosynthetic CO2 uptake and isotopic discrimination. Significantly higher NEE fluxes were observed for both daytime uptake and nighttime respiration during well-watered conditions when compared to a drought period. Given these differences, we investigated two carbon-flux partitioning questions: (1) What proportions of NEE were contributed by C3 versus C4 species? (2) What proportions of NEE fluxes resulted from canopy assimilation versus ecosystem respiration? To evaluate these questions, air samples were collected every 2 hours during daytime for 3 consecutive days at the same height as the eddy covariance system. These air samples were analyzed for both carbon isotope ratios and CO2 concentrations to establish an empirical relationship for isoflux calculations. An automated air sampling system was used to collect nighttime air samples to estimate the carbon isotope ratios of ecosystem respiration (δR) at weekly intervals for the entire growing season. Models of C3 and C4 photosynthesis were employed to estimate bulk canopy intercellular CO2 concentration in order to calculate photosynthetic discrimination against 13C. Our isotope/NEE results showed that for this grassland, C4 vegetation contributed ˜80% of the NEE fluxes during the drought period and later ˜100% of the NEE fluxes in response to an impulse of intense precipitation. For the entire growing season, the C4 contribution ranged from ˜68% early in the spring to nearly 100% in the late summer. Using an isotopic approach, the calculated partitioned respiratory fluxes were slightly greater than chamber-measured estimates during midday under well-watered conditions. In addition, time series

  4. Technical assessment of TRUSAF for compliance with work place air sampling. Revision 1

    SciTech Connect

    Butler, J.D.

    1995-01-23

    The purpose of this Technical Work Document is to satisfy WHC-CM-1-6, the ``WHC Radiological Control Manual.`` This first revision of the original Supporting Document covers the period from January 1, 1994 to December 31, 1994. WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ``Hanford Site Radiological Control Manual`` and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. this document also provides an evaluation of the compliance of the TRUSAF workplace air sampling program to the criteria, standards, and requirements and documents. Where necessary, it also indicates changes needed to bring specific locations into compliance.

  5. Technical assessment of workplace air sampling requirements at tank farm facilities. Revision 1

    SciTech Connect

    Olsen, P.A.

    1994-09-21

    WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). It was written to implement DOE N 5480.6 ``US Department of Energy Radiological Control Manual`` as it applies to programs at Hanford which are now overseen by WHC. As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ``Hanford Site Radiological Control Manual`` and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. This document also provides an evaluation of the compliance of Tank Farms` workplace air sampling program to the criteria, standards, and requirements and documents compliance with the requirements where appropriate. Where necessary, it also indicates changes needed to bring specific locations into compliance.

  6. Development of a local continuous sampling probe for the equivalence air-fuel ratio measurement. Application to spark ignition engine

    NASA Astrophysics Data System (ADS)

    Guibert, P.; Dicocco, E.

    This paper is a contribution to the development of an original technique for measuring the in-cylinder equivalence air-fuel ratio. The main objective was to construct an instrument able to furnish instantaneous values of hydrocarbon concentration for many consecutive cycles at a definite location, especially at the spark plug location. The probe is based on a hot-wire-like apparatus, but involves catalytic oxidation on the wire surface in order to be sensitive to the hydrocarbon concentration. In this paper, we present the different steps needed to develop and validate the probe. The first step focuses on the geometric configuration to simplify as much as possible the mass transfer phenomena on the wire. The second step is a parametric study to evaluate the sensitivity, confidence and lifetime of the wire. By physical analysis, we propose a relationship between the electrical signal and the air-fuel equivalence ratio of the sampled gases. The third step is the application of the probe to in-cylinder motored engine measurements, which confirms the ability of the technique to characterise, quantitatively, the homogeneity of the air-fuel mixture, especially during the compression stroke. This work points out that the global sensitivity is estimated at 4V per unit of equivalence air-fuel ratio and the response time is estimated at about 400μs. The equivalence air-fuel ratio range is from pure air to 1.2. Experiments show that it is necessary to calibrate the system before use because of the existence of multiple catalysis states. The probe presents advantages associated with its simplicity, its low cost and its direct engine application without any modifications.

  7. Long-term measurement of volatile organic compounds in ambient air by canister-based one-week sampling method.

    PubMed

    Ochiai, Nobuo; Daishima, Shigeki; Cardin, Daniel B

    2003-12-01

    A canister-based 1 week sampling method using a mechanical flow controller and a 6 L fused-silica-lined canister was evaluated for the long-term measurement of 47 VOCs in ambient air at pptv (volume/volume) to ppbv levels by use of a three-stage preconcentation method followed by GC-MS analysis. The GC conditions were initially optimized for complete separations of several pptv-level VOCs (e.g. vinyl chloride, 1,3-butadiene, acrylonitrile, 1,2-dichloroethane and chloroform) in ambient air because the selected ions are easily interfered with by coexisting C4-, C5-hydrocarbons and analytes presented at ppbv levels. Thirty-four VOCs determined by the 1 week and 24 h sampling method in December 16-22 (2002) had concentrations of 6.0-15000 pptv per compound. Concentrations of 28 VOCs (including polar VOCs (e.g. methyl isobutyl ketone and butyl acetate)) obtained by the method were approximately equal to the mean values calculated from 24 h sampling (< +/- 10% deviation). Six VOCs that had low concentrations of 6.0-43 pptv showed more than +/- 10% deviation. Thirteen VOCs were not detected during the entire sampling period. The effect of relative humidity or ozone for the specific VOCs (e.g. MIBK, butyl acetate, vinyl chloride, 1,3-butadiene and styrene) was negligible. PMID:14710945

  8. Thermodynamic Analysis of a Novel Liquid Air Energy Storage System

    NASA Astrophysics Data System (ADS)

    Xue, X. D.; Wang, S. X.; Zhang, X. L.; Cui, C.; Chen, L. B.; Zhou, Y.; Wang, J. J.

    In this study, a novel liquid air energy storage system for electrical power load shifting application is introduced. It is a combination of an air liquefaction cycle and a gas turbine power generation cycle without fuel combustion. Thermodynamic analysis is conducted to investigate the performance of this system. The results show that liquid air energy storage systems could be very effective systems for electrical power storage with high efficiency, high energy density and extensive application prospects.

  9. Measurement of the Tracer Gradient and Sampling System Bias of the Hot Fuel Examination Facility Stack Air Monitoring System

    SciTech Connect

    Glissmeyer, John A.; Flaherty, Julia E.

    2011-07-20

    This report describes tracer gas uniformity and bias measurements made in the exhaust air discharge of the Hot Fuel Examination Facility at Idaho National Laboratory. The measurements were a follow-up on earlier measurements which indicated a lack of mixing of the two ventilation streams being discharged via a common stack. The lack of mixing is detrimental to the accuracy of air emission measurements. The lack of mixing was confirmed in these new measurements. The air sampling probe was found to be out of alignment and that was corrected. The suspected sampling bias in the air sample stream was disproved.

  10. Tank 241-TY-103 rotary core sampling and analysis

    SciTech Connect

    Jo, J.

    1995-10-30

    This Sampling and Analysis Plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for two rotary-mode core samples from tank 241-TY-103

  11. Sampling and analysis plan for canister liquid and gas sampling at 105 KW fuel storage basin

    SciTech Connect

    Trimble, D.J.

    1996-08-09

    This Sampling and Analysis Plan describes the equipment,procedures and techniques for obtaining gas and liquid samples from sealed K West fuel canisters. The analytical procedures and quality assurance requirements for the subsequent laboratory analysis of the samples are also discussed.

  12. Colling Wipe Samples for VX Analysis

    SciTech Connect

    Koester, C; Hoppes, W G

    2010-02-11

    This standard operating procedure (SOP) provides uniform procedures for the collection of wipe samples of VX residues from surfaces. Personnel may use this procedure to collect and handle wipe samples in the field. Various surfaces, including building materials (wood, metal, tile, vinyl, etc.) and equipment, may be sampled based on this procedure. The purpose of such sampling is to determine whether or not the relevant surfaces are contaminated, to determine the extent of their contamination, to evaluate the effectiveness of decontamination procedures, and to determine the amount of contaminant that might present as a contact hazard.

  13. PIXE and XRF analysis of honey samples

    NASA Astrophysics Data System (ADS)

    Braziewicz, J.; Fijał, I.; Czyżewski, T.; Jaskóła, M.; Korman, A.; Banaś, D.; Kubala-Kukuś, A.; Majewska, U.; Zemło, L.

    2002-02-01

    The systematic determination of trace-element concentrations in honey samples was done by the PIXE method using a 2 MeV proton beam and by the total reflection XRF method. The different kinds of honey samples were collected in the period of spring-summer in three places of Poland: in the centre of Warsaw (a highly polluted region) and about 100 km east of Warsaw and 70 km southwest of Warsaw (as regions free from industrial and transport pollution). The measured samples have shown that the concentrations of trace elements are similar in the honey samples from these places.

  14. Collection of Samples for DNA Analysis.

    PubMed

    van Oorschot, Roland A H; Verdon, Timothy J; Ballantyne, Kaye N

    2016-01-01

    Effective sampling of biological material is critical to the ability to acquire DNA profiles of probative value. The main methods of collection are swabbing, tapelifting, or direct excision. This chapter describes the key aspects to consider when applying these methods, in addition to suggested procedures for swabbing and tapelifting. Important issues to be considered, such as exhibit triaging, pre-examination preparation, contamination risk reduction, sample localization, sample identification, and sample prioritization as well as aspects of record keeping, packaging, and storage, are also raised. PMID:27259727

  15. Airborne Detection and Quantification of Swine Influenza A Virus in Air Samples Collected Inside, Outside and Downwind from Swine Barns

    PubMed Central

    Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164

  16. 7 CFR 58.812 - Methods of sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Methods of sample analysis. 58.812 Section 58.812... Procedures § 58.812 Methods of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL, as issued by the USDA,...

  17. 40 CFR 92.129 - Exhaust sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Exhaust sample analysis. 92.129... sample analysis. (a) The analyzer response may be read by automatic data collection (ADC) equipment such... “before” span check for the next mode. (d) For sample analysis perform the following sequence: (1)...

  18. 40 CFR 265.92 - Sampling and analysis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Sampling and analysis. 265.92 Section... FACILITIES Ground-Water Monitoring § 265.92 Sampling and analysis. (a) The owner or operator must obtain and... follow a ground-water sampling and analysis plan. He must keep this plan at the facility. The plan...

  19. 40 CFR 600.112-08 - Exhaust sample analysis.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Exhaust sample analysis. 600.112-08 Section 600.112-08 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY... Exhaust sample analysis. The exhaust sample analysis must be performed according to § 86.140, or §...

  20. 7 CFR 58.245 - Method of sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Method of sample analysis. 58.245 Section 58.245... Procedures § 58.245 Method of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL as issued by the USDA, Agricultural...

  1. 40 CFR 600.112-78 - Exhaust sample analysis.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Exhaust sample analysis. 600.112-78 Section 600.112-78 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY... Exhaust sample analysis. The exhaust sample analysis must be performed according to § 86.140 of...

  2. 40 CFR 265.92 - Sampling and analysis.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Sampling and analysis. 265.92 Section... FACILITIES Ground-Water Monitoring § 265.92 Sampling and analysis. (a) The owner or operator must obtain and... follow a ground-water sampling and analysis plan. He must keep this plan at the facility. The plan...

  3. 40 CFR 265.92 - Sampling and analysis.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Sampling and analysis. 265.92 Section... FACILITIES Ground-Water Monitoring § 265.92 Sampling and analysis. (a) The owner or operator must obtain and... follow a ground-water sampling and analysis plan. He must keep this plan at the facility. The plan...

  4. 7 CFR 58.245 - Method of sample analysis.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Service, Dairy Programs, or Official Methods of Analysis of the Association of Analytical Chemists or... 7 Agriculture 3 2011-01-01 2011-01-01 false Method of sample analysis. 58.245 Section 58.245... Procedures § 58.245 Method of sample analysis. Samples shall be tested according to the applicable methods...

  5. 7 CFR 58.812 - Methods of sample analysis.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Marketing Service, Dairy Programs, or the Official Methods of Analysis of the Association of Official... 7 Agriculture 3 2011-01-01 2011-01-01 false Methods of sample analysis. 58.812 Section 58.812... Procedures § 58.812 Methods of sample analysis. Samples shall be tested according to the applicable...

  6. ANALYSIS OF SELECTED SAMPLES FOR METALS UPTAKE

    EPA Science Inventory

    Grass samples were collected from the Contrary Creek/D. Boyd Smith reclamation project of the Virginia Water Quality Control Board and the Anvil Points mine treatment experimental facility. Fish samples were collected from the EPA's mine water treatment experimental facility's sl...

  7. Space X First Entry Sample Analysis

    NASA Technical Reports Server (NTRS)

    James, John T.

    2012-01-01

    The toxicological assessment of one sample collected on May 26, 2012 and returned to earth on May 31, 2012 was analyzed for pollutants that had offgassed into the Dragon capsule by the time of first entry operations performed by the ISS crew. The components identified in the first-entry sample and their contributions to the total T-value are shown.

  8. Sampling artifacts in active air sampling of semivolatile organic contaminants: Comparing theoretical and measured artifacts and evaluating implications for monitoring networks.

    PubMed

    Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Klánová, Jana

    2016-10-01

    The effects of sampling artifacts are often not fully considered in the design of air monitoring with active air samplers. Semivolatile organic contaminants (SVOCs) are particularly vulnerable to a range of sampling artifacts because of their wide range of gas-particle partitioning and degradation rates, and these can lead to erroneous measurements of air concentrations and a lack of comparability between sites with different environmental and sampling conditions. This study used specially adapted filter-sorbent sampling trains in three types of active air samplers to investigate breakthrough of SVOCs, and the possibility of other sampling artifacts. Breakthrough volumes were experimentally determined for a range of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polybrominated diphenyl ethers (PBDEs) in sampling volumes from 300 to 10,000 m(3), and sampling durations of 1-7 days. In parallel, breakthrough was estimated based on theoretical sorbent-vapor pressure relationships. The comparison of measured and theoretical determinations of breakthrough demonstrated good agreement between experimental and estimated breakthrough volumes, and showed that theoretical breakthrough estimates should be used when developing air monitoring protocols. Significant breakthrough in active air samplers occurred for compounds with vapor pressure >0.5 Pa at volumes <700 m(3). Sample volumes between 700 and 10,000 m(3) may lead to breakthrough for compounds with vapor pressures between 0.005 and 0.5 Pa. Breakthrough is largely driven by sample volume and compound volatility (therefore indirectly by temperature) and is independent of sampler type. The presence of significant breakthrough at "typical" sampling conditions is relevant for air monitoring networks, and may lead to under-reporting of more volatile SVOCs. PMID:26743995

  9. Nonuniform air flow in inlets: the effect on filter deposits in the fiber sampling cassette.

    PubMed

    Baron, P A; Chen, C C; Hemenway, D R; O'Shaughnessy, P

    1994-08-01

    Smoke stream studies were combined with a new technique for visualizing a filter deposit from samples used to monitor asbestos or other fibers. Results clearly show the effect of secondary flow vortices within the sampler under anisoaxial sampling conditions. The vortices observed at low wind velocities occur when the inlet axis is situated at angles between 45 degrees and 180 degrees to the motion of the surrounding air. It is demonstrated that the vortices can create a complex nonuniform pattern in the filter deposit, especially when combined with particle settling or electrostatic interactions between the particles and the sampler. Inertial effects also may play a role in the deposit nonuniformity, as well as causing deposition on the cowl surfaces. Changes in the sampler, such as its placement, may reduce these biases. The effects noted are not likely to occur in all sampling situations, but may explain some reports of high variability on asbestos fiber filter samples. The flow patterns observed in this study are applicable to straight, thin-walled inlets. Although only compact particles were used, the air flow patterns and forces involved will have similar effects on fibers of the same aerodynamic diameter. PMID:7942509

  10. TAPAS: Topographic air pollution analysis system. Technical note

    SciTech Connect

    Riebau, A.; Fox, D.A.; Marlatt, W.E.

    1987-05-01

    This report presents information on the Topographic Air Pollution Analysis System (TAPAS), currentlu under development by the Bureau of Land Management, U.S. Forest Service, and Colorado State University. TAPAS is designed to provide resource managers with air quality dispersion modeling tools to accomplish more efficient and economical air resource studies. TAPAS consists of a group of interactive air quality computer models that can be operated independently, or in combination for more detailed applications. TAPAS applications include support for resource management plans, environmental impact statements, siting of remote automatic weather stations, PSD permit evaluations, and smoke management for prescribed burns.

  11. Developments in Sampling and Analysis Instrumentation for Stationary Sources

    ERIC Educational Resources Information Center

    Nader, John S.

    1973-01-01

    Instrumentation for the measurement of pollutant emissions is considered including sample-site selection, sample transport, sample treatment, sample analysis, and data reduction, display, and interpretation. Measurement approaches discussed involve sample extraction from within the stack and electro-optical methods. (BL)

  12. Biomimetic air sampling for detection of low concentrations of molecules and bioagents : LDRD 52744 final report.

    SciTech Connect

    Hughes, Robert Clark

    2003-12-01

    Present methods of air sampling for low concentrations of chemicals like explosives and bioagents involve noisy and power hungry collectors with mechanical parts for moving large volumes of air. However there are biological systems that are capable of detecting very low concentrations of molecules with no mechanical moving parts. An example is the silkworm moth antenna which is a highly branched structure where each of 100 branches contains about 200 sensory 'hairs' which have dimensions of 2 microns wide by 100 microns long. The hairs contain about 3000 pores which is where the gas phase molecules enter the aqueous (lymph) phase for detection. Simulations of diffusion of molecules indicate that this 'forest' of hairs is 'designed' to maximize the extraction of the vapor phase molecules. Since typical molecules lose about 4 decades in diffusion constant upon entering the liquid phase, it is important to allow air diffusion to bring the molecule as close to the 'sensor' as possible. The moth acts on concentrations as low as 1000 molecules per cubic cm. (one part in 1e16). A 3-D collection system of these dimensions could be fabricated by micromachining techniques available at Sandia. This LDRD addresses the issues involved with extracting molecules from air onto micromachined structures and then delivering those molecules to microsensors for detection.

  13. In-air micro-PIGE measurement system for fluorine analysis of the tooth

    NASA Astrophysics Data System (ADS)

    Yasuda, K.; Hai, V. H.; Nomachi, M.; Sugaya, Y.; Yamamoto, H.

    2007-07-01

    An in-air micro-PIGE and micro-PIXE measurement system for fluorine analysis of tooth have been developed at the Wakasa Wan Energy Research Center. A proton microbeam is extracted through a thin silicon nitride window into the air and used to irradiate a tooth sample mounted on a sample stage set in air. Gamma-rays from a 19F(p, αγ) 16O reaction and characteristic X-rays are detected with a BGO detector and a Ge X-ray detector, simultaneously. The sample stage and beam scanner allow us to analyze the tooth sample over a range of 20 mm at maximum. Spot sizes of a proton beams in air at an energy of 2.5 MeV was 4 μm, in the case of a distance between the silicon nitride window and the sample of 0.2 mm and 13 μm in the case of 1.7 mm. Fluorine analysis was performed over an area of about 3 mm × 3 mm of the tooth sample. One- and two-dimensional distributions of fluorine and calcium were obtained successfully. Quantitative analysis was also performed using data for measurements of reference materials Ca 10(PO 4) 6(OH) 2-2 xF 2 x.

  14. Proportional counter device for detecting electronegative species in an air sample

    DOEpatents

    Allman, S.L.; Chen, F.C.; Chen, C.H.

    1994-03-08

    Apparatus for detecting an electronegative species comprises an analysis chamber, an inlet communicating with the analysis chamber for admitting a sample containing the electronegative species and an ionizable component, a radioactive source within the analysis chamber for emitting radioactive energy for ionizing a component of the sample, a proportional electron detector within the analysis chamber for detecting electrons emitted from the ionized component, and a circuit for measuring the electrons and determining the presence of the electronegative species by detecting a reduction in the number of available electrons due to capture of electrons by the electronegative species. 2 figures.

  15. Proportional counter device for detecting electronegative species in an air sample

    DOEpatents

    Allman, Steve L.; Chen, Fang C.; Chen, Chung-Hsuan

    1994-01-01

    Apparatus for detecting an electronegative species comprises an analysis chamber, an inlet communicating with the analysis chamber for admitting a sample containing the electronegative species and an ionizable component, a radioactive source within the analysis chamber for emitting radioactive energy for ionizing a component of the sample, a proportional electron detector within the analysis chamber for detecting electrons emitted from the ionized component, and a circuit for measuring the electrons and determining the presence of the electronegative species by detecting a reduction in the number of available electrons due to capture of electrons by the electronegative species.

  16. Quantifying water and air redistribution in heterogeneous sand sample by neutron imaging

    NASA Astrophysics Data System (ADS)

    Šácha, Jan; Sobotková, Martina; Jelínková, Vladimíra; Sněhota, Michal; Vontobel, Peter; Hovind, Jan

    2014-05-01

    Significant temporal variation of quasi saturated hydraulic conductivity (Kqs) has been observed to date in number of infiltration experiments conducted mainly on heterogeneous soil of Cambisol. The change of quasi-saturated hydraulic conductivity cannot be precisely described by existing models. The Kqs variations has been recently attributed to a changing distribution of the entrapped air and water within the sample. It is expected that air is moved to the preferential pathway and acts as a barrier there. To support this assumption a ponded infiltration experiment was conducted on a soil sample packed into the quartz glass column of inner diameter of 34 mm. The sample composition represents simplified heterogeneity of the natural soil but also allow the easy quantitative water content determination in individual subdomains of the sample. The matrix formed by a fine sand was surrounded with regions of coarse sand representing preferential flow pathways. The Kqs was determined from the known hydraulic gradient and measured volume flux. The experiment was monitored by neutron radiography. Volume of water in the sample calculated from neutron projections matched very well with actually infiltrated volume in the sample during first 40 second after beginning of infiltration. From the acquired radiographic images the 3D tomography images were reconstructed to obtain the spatial distribution of the water content within the sample. Difference between water volume calculated from radiography and tomography images was no more than 5%. While the total amount of water determined by NR within the sample during the quasi steady state flow remains practically constant (27.9 cm3 at the beginning and 28.6 cm3 on the end of infiltration) the water content in the coarse fraction decreases (from 0.333 to 0.324) and the water content in the fine fraction increases (from 0.414 to 0.436) in 5 hours. Similarly to previous experiments performed on natural Cambisols, the results support

  17. Glyphosate–rich air samples induce IL–33, TSLP and generate IL–13 dependent airway inflammation

    PubMed Central

    Kumar, Sudhir; Khodoun, Marat; Kettleson, Eric M.; McKnight, Christopher; Reponen, Tiina; Grinshpun, Sergey A.; Adhikari, Atin

    2014-01-01

    Several low weight molecules have often been implicated in the induction of occupational asthma. Glyphosate, a small molecule herbicide, is widely used in the world. There is a controversy regarding a role of glyphosate in developing asthma and rhinitis among farmers, the mechanism of which is unexplored. The aim of this study was to explore the mechanisms of glyphosate induced pulmonary pathology by utilizing murine models and real environmental samples. C57BL/6, TLR4−/−, and IL-13−/− mice inhaled extracts of glyphosate-rich air samples collected on farms during spraying of herbicides or inhaled different doses of glyphosate and ovalbumin. The cellular response, humoral response, and lung function of exposed mice were evaluated. Exposure to glyphosate-rich air samples as well as glyphosate alone to the lungs increased: eosinophil and neutrophil counts, mast cell degranulation, and production of IL-33, TSLP, IL-13, and IL-5. In contrast, in vivo systemic IL-4 production was not increased. Co-administration of ovalbumin with glyphosate did not substantially change the inflammatory immune response. However, IL-13-deficiency resulted in diminished inflammatory response but did not have a significant effect on airway resistance upon methacholine challenge after 7 or 21 days of glyphosate exposure. Glyphosate-rich farm air samples as well as glyphosate alone were found to induce pulmonary IL-13-dependent inflammation and promote Th2 type cytokines, but not IL-4 for glyphosate alone. This study, for the first time, provides evidence for the mechanism of glyphosate-induced occupational lung disease. PMID:25172162

  18. Final work plan : indoor air and ambient air sampling near the former CCC/USDA grain storage facility in Everest, Kansas.

    SciTech Connect

    LaFreniere, L. M.

    2010-05-24

    The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at the western edge of Everest, Kansas, from the early 1950s to the early 1970s. Sampling by the Kansas Department of Health and Environment (KDHE) in 1997 resulted in the detection of carbon tetrachloride in one domestic well (the Nigh well) northwest of the former facility. On behalf of the CCC/USDA, Argonne National Laboratory subsequently conducted a series of investigations to characterize the contamination (Argonne 2003, 2006a,b,c). Automatic, continuous monitoring of groundwater levels began in 2002 and is ongoing at six locations. The results have consistently indicated groundwater flow toward the north-northwest from the former CCC/USDA property to the Nigh property, then west-southwest from the Nigh property to the intermittent creek. Sitewide periodic groundwater and surface water sampling with analysis for volatile organic compounds (VOCs) began in 2008. Argonne's combined data indicate no significant downgradient extension of contamination since 2000. At present, the sampling is annual, as approved by the KDHE (2009) in response to a plan developed for the CCC/USDA (Argonne 2009). This document presents a plan for collecting indoor air samples in homes located along and adjacent to the defined extent of the carbon tetrachloride contamination. The plan was requested by the KDHE. Ambient air samples to represent the conditions along this pathway will also be taken. The purpose of the proposed work is to satisfy KDHE requirements and to collect additional data for assessing the risk to human health due to the potential upward migration of carbon tetrachloride and its primary degradation product (chloroform) into homes located in close proximity to the former grain storage facility, as well as along and within 100 ft laterally from the currently defined plume emanating from the former Everest facility. Investigation of the indoor air

  19. Analysis of dinosaur samples by nuclear microscopy

    NASA Astrophysics Data System (ADS)

    Wu, Xiankang; Orlić, I.; Tang, S. M.; Wang, Yiming; Wang, Xiaohong; Zhu, Jieqing

    1997-07-01

    Several dinosaur bone and eggshell fossil samples unearthed at different sites in China were analyzed by means of nuclear microscopy. Concentrations and distributions of elements such as Na, Mg, Al, P, S, Ca, Cr, Mn, Fe, Cu, Zn, As, Br, Sr, Y, Ce, Pb and U, etc. were obtained for each sample. The results of quantitative PIXE and RBS analyses show unusually high concentrations of U and Ce in several samples obtained from a period near the K-T boundary (between Cretaceous and Tertiary periods, 65 million years ago), suggesting that some form of environmental pollution could be the cause of dinosaur extinction.

  20. Sampling size in the verification of manufactured-supplied air kerma strengths

    SciTech Connect

    Ramos, Luis Isaac; Martinez Monge, Rafael

    2005-11-15

    Quality control mandate that the air kerma strengths (S{sub K}) of permanent seeds be verified, this is usually done by statistics inferred from 10% of the seeds. The goal of this paper is to proposed a new sampling method in which the number of seeds to be measured will be set beforehand according to an a priori statistical level of uncertainty. The results are based on the assumption that the S{sub K} has a normal distribution. To demonstrate this, the S{sub K} of each of the seeds measured was corrected to ensure that the average S{sub K} of its sample remained the same. In this process 2030 results were collected and analyzed using a normal plot. In our opinion, the number of seeds sampled should be determined beforehand according to an a priori level of statistical uncertainty.

  1. The contribution of nitro- and methylnitronaphthalenes to the vapor-phase mutagenicity of ambient air samples

    NASA Astrophysics Data System (ADS)

    Gupta, Pamela; Harger, William P.; Arey, Janet

    1- and 2-Nitronaphthalene (NN) and the 14 methylnitronaphthalene (MNN) isomers were identified and quantified in ambient vapor-phase samples collected in Redlands, CA during moderate photochemical air pollution. The mutagenic activities of NN and MNN standards were determined using a microsuspension-preincubation modification of the Ames Salmonella bacterial reversion assay in strain TA98 without microsomal activation. The calculated contributions of the NNs and MNNs to the total vapor-phase ambient mutagenic activity were ˜ 18 and ˜ 32% for daytime and nighttime composite samples, respectively. Enhanced mutagenic activity in the nighttime sample was attributed to NN and MNN formation from nighttime N03 radical-initiated reactions of naphthalene and the methylnaphthalenes.

  2. SYSTEMATIC SENSITIVITY ANALYSIS OF AIR QUALITY SIMULATION MODELS

    EPA Science Inventory

    This report reviews and assesses systematic sensitivity and uncertainty analysis methods for applications to air quality simulation models. The discussion of the candidate methods presents their basic variables, mathematical foundations, user motivations and preferences, computer...

  3. BMEWS Capture and Analysis of Reflected Energy Clear Air ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    BMEWS Capture and Analysis of Reflected Energy - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  4. Sampling and preparation of samples of peanut butter for aflatoxin analysis.

    PubMed

    Waltking, A E

    1980-01-01

    Procedures are discussed for sampling peanut butter and preparing those samples for alatoxin analysis. Special emphasis is placed on sampling the product from shipping pallets and comminuting chunk stype peanut butter in order to reduce the variability in the analysis associated with the nonuniform distribution of aflatoxin in the product. The slurry method of preparation is a convenient means of obtaining a sample which is representative of a nonhomogeneous product. PMID:7380779

  5. Remote mass spectrometric sampling of electrospray- and desorption electrospray-generated ions using an air ejector.

    PubMed

    Dixon, R Brent; Bereman, Michael S; Muddiman, David C; Hawkridge, Adam M

    2007-10-01

    A commercial air ejector was coupled to an electrospray ionization linear ion trap mass spectrometer (LTQ) to transport remotely generated ions from both electrospray (ESI) and desorption electrospray ionization (DESI) sources. We demonstrate the remote analysis of a series of analyte ions that range from small molecules and polymers to polypeptides using the AE-LTQ interface. The details of the ESI-AE-LTQ and DESI-AE-LTQ experimental configurations are described and preliminary mass spectrometric data are presented. PMID:17716909

  6. Remote Mass Spectrometric Sampling of Electrospray- and Desorption Electrospray-Generated Ions Using an Air Ejector

    PubMed Central

    Dixon, R. Brent; Bereman, Michael S.; Muddiman, David C.; Hawkridge, Adam M.

    2007-01-01

    A commercial air ejector was coupled to an electrospray ionization linear ion trap mass spectrometer (LTQ) to transport remotely generated ions from both electrospray (ESI) and desorption electrospray ionization (DESI) sources. We demonstrate the remote analysis of a series of analyte ions that range from small molecules and polymers to polypeptides using the AE-LTQ interface. The details of the ESI-AE-LTQ and DESI-AE-LTQ experimental configurations are described and preliminary mass spectrometric data is presented. PMID:17716909

  7. Soyuz 23 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    James, John T.

    2011-01-01

    Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 23 because of concerns that new air pollutants had been present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The TOC began to decline in late October, 2010. The toxicological assessment of 6 m-GSCs from the ISS is shown in Table 1. The recoveries of 13C-acetone, fluorobenzene, and chlorobenzene from the GSCs averaged 73, 82, and 59%, respectively. We are working to understand the sub-optimal recovery of chlorobenzene.

  8. WRAP Module 1 sampling and analysis plan

    SciTech Connect

    Mayancsik, B.A.

    1995-03-24

    This document provides the methodology to sample, screen, and analyze waste generated, processed, or otherwise the responsibility of the Waste Receiving and Processing Module 1 facility. This includes Low-Level Waste, Transuranic Waste, Mixed Waste, and Dangerous Waste.

  9. LABORATORY GUIDELINES FOR ANALYSIS OF BIOTERRORISM SAMPLES

    EPA Science Inventory

    With advent of deaths associated with Bacillus anthracis spore contaminated mail, a worldwide need was apparent for increased laboratory capacity to safely analyze bioterrorism samples. The U.S. Department of Health and Human Services has furnished guidelines for microbiological...

  10. SAMPLING AND ANALYSIS OF SEMIVOLATILE AEROSOLS

    EPA Science Inventory

    Denuder based samplers can effectively separate semivolatile gases from particles and 'freeze' the partitioning in time. Conversely, samples collected on filters partition mass according to the conditions of the influent airstream, which may change over time. As a result thes...

  11. AIR INGRESS ANALYSIS: COMPUTATIONAL FLUID DYNAMIC MODELS

    SciTech Connect

    Chang H. Oh; Eung S. Kim; Richard Schultz; Hans Gougar; David Petti; Hyung S. Kang

    2010-08-01

    The Idaho National Laboratory (INL), under the auspices of the U.S. Department of Energy, is performing research and development that focuses on key phenomena important during potential scenarios that may occur in very high temperature reactors (VHTRs). Phenomena Identification and Ranking Studies to date have ranked an air ingress event, following on the heels of a VHTR depressurization, as important with regard to core safety. Consequently, the development of advanced air ingress-related models and verification and validation data are a very high priority. Following a loss of coolant and system depressurization incident, air will enter the core of the High Temperature Gas Cooled Reactor through the break, possibly causing oxidation of the in-the core and reflector graphite structure. Simple core and plant models indicate that, under certain circumstances, the oxidation may proceed at an elevated rate with additional heat generated from the oxidation reaction itself. Under postulated conditions of fluid flow and temperature, excessive degradation of the lower plenum graphite can lead to a loss of structural support. Excessive oxidation of core graphite can also lead to the release of fission products into the confinement, which could be detrimental to a reactor safety. Computational fluid dynamic model developed in this study will improve our understanding of this phenomenon. This paper presents two-dimensional and three-dimensional CFD results for the quantitative assessment of the air ingress phenomena. A portion of results of the density-driven stratified flow in the inlet pipe will be compared with results of the experimental results.

  12. Air Ingress Analysis: Part 1 - Theoretical Approach

    SciTech Connect

    Chang Ho Oh

    2011-01-01

    Idaho National Laboratory (INL), under the auspices of the U.S. Department of Energy (DOE), is performing research and development that focuses on key phenomena important during potential scenarios that may occur in very high temperature gas-cooled reactors (VHTRs). Phenomena identification and ranking studies to date have ranked an air ingress event, following on the heels of a VHTR depressurization, as important with regard to core safety. Consequently, the development of advanced air-ingress-related models and verification and validation data are a very high priority. Following a loss of coolant and system depressurization incident, air will enter the core of the VHTR through the break, possibly causing oxidation of the graphite core and reflector graphite structure. Simple core and plant models indicate that, under certain circumstances, the oxidation may proceed at an elevated rate with additional heat generated from the oxidation reaction itself. Under postulated conditions of fluid flow and temperature, excessive degradation of lower plenum graphite caused by graphite oxidation can lead to a loss of mechanical strength. Excessive oxidation of core graphite can also lead to a release of fission products into the confinement, which could be detrimental to reactor safety. Analytical models developed in this study will improve our understanding of this phenomenon. This paper presents two sets of analytical models for the qualitative assessment of the air ingress phenomena. The results from the analytical models are compared with results of the computational fluid dynamic models (CFD) in the subsequent paper. The analytical models agree well with those CFD results.

  13. An experiment to determine atmospheric CO concentrations of tropical South Atlantic air samples

    NASA Astrophysics Data System (ADS)

    Kirchhoff, V. W. J. H.; Aires, C. B.; Alvala, P. C.

    2003-04-01

    New observations of atmospheric carbon monoxide, CO, are described, from tropical South Atlantic air samples. A new observational site, Maxaranguape, was set up in a clean remote environment right next to the ocean on the north-east coast of Brazil, to obtain CO mixing ratios and auxiliary data (meteorological parameters, ozone (O3), carbon dioxide (CO2) and methane (CH4)) during three sequential seasonal cycles. The seasonal variations of temperature, humidity and precipitation are shown for the new site. Chromatographic separation followed by mercury oxide detection is used to measure CO. The seasonality of the CO data was clearly established. Minima are seen during April, May and June showing wet-period averages of 56.1 parts per billion by volume (ppbv), with standard deviation 8.7 ppbv; during dry-period months, August to November, the average was 77.7 ± 16.5 ppbv. For comparison, CO concentrations were also measured over continental areas in Brazil. Much larger values have been found in moderate 'burning' regions, such as the south of the state of Mato Grosso and the north-western part of the state of Parana, where 200 ppbv in the dry season has been observed. Since normally the air masses have travelled for several days over the ocean, the air masses over the site present low chemical activity. Daily variations of CO2 are very small, of the order of a few percent relative to the diurnal mean. Only on rare occasions, when the wind direction changes, is the sampled air contaminated from flowing over the inhabited shoreline to the south, and then CO2 varies inversely with O3. The monthly mean CH4 data does not show a clear seasonal variation, possibly because the amplitude of the CH4 variation is only of the order of 1%, which is close to the precision of the measuring instrument.

  14. Method validation program for the long duration sampling of PCDDs/PCDFs in ambient air

    SciTech Connect

    Maisel, B.E.; Hunt, G.T.; Hoyt, M.P.; Rowe, N.; Scarfo, L.

    1994-12-31

    A method validation program was completed to assess the technical viability of extended, long duration sampling periods (15- and 30-day) for the collection of PCDDs/PCDFs in ambient air in lieu of the 48-hour sampling periods typically employed. This long duration approach, if successful, would provide measurements data more representative of average ambient PCDDs/PCDFs levels on an annual basis, and hence provide enhanced support of the 1.0 pg/m{sup 3} annual ambient standard for PCDDs/PCDFs (expressed at 1987 EPA toxic equivalents) required by Connecticut regulation. The method validation program utilized nine collocated PUF samplers which were operated for 15-day and 30-day periods during each of two seasonal monitoring campaigns (winter and summer). Samples were analyzed using high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) based on EPA Method 8290. Each PUF cartridge consisted of two foam halves; the top half PUF and filter were analyzed as a single sample separately from the bottom half PUF section. This approach provided an assessment of analyte breakthrough using the sampling system for large sample volumes of approximately 4,000 m{sup 3} and 8,000 m{sup 3} for the 15-day and respectively.

  15. SAMPLING AND ANALYSIS RESEARCH PROGRAM AT THE PARAHO SHALE OIL DEMONSTRATION PLANT

    EPA Science Inventory

    A sampling and analysis research program was conducted at the Paraho oil shale retorting demonstration site at Anvil Points, Colorado. The overall objective of the test program was to obtain preliminary quantitative and qualitative measurements of air, water, and solid compositio...

  16. Passive air sampling of organochlorine pesticides, polychlorinated biphenyls, and polybrominated diphenyl ethers across the tibetan plateau.

    PubMed

    Wang, Xiao-Ping; Gong, Ping; Yao, Tan-Dong; Jones, Kevin C

    2010-04-15

    So far there are limited data on persistent organic pollutants (POPs) in the atmosphere of the Tibetan Plateau. XAD 2-resin based passive air samplers were therefore deployed for 1 year (between July 2007-June 2008) at 16 locations across the Tibetan Plateau. Based on previously reported sampling rates (R) derived in the north and south America, and their correlations with atmospheric temperature and pressure, R values in the present study were in the range of 2.2-3.3 m(3) d(-1) (average = 2.7 +/- 0.3). Derived air concentrations (pg/m(3)) ranged as follows: DDTs, 5-75; HCHs, 0.1-36; alpha-endosulfan, 0.1-10; HCB, 2.8-80; sum of 15 PCBs, 1.8-8.2; and sum of 9 PBDEs, 0.1-8.3. The highest DDTs occurred at Qamdo, where the sampling site is near to farm land, indicating the spatial distribution of DDTs across the plateau may be influenced by scattered local usage of DDT. Higher levels of HCHs were observed at sites with high elevation (>4000 m) and close to the China-India border, indicating possible long-range atmospheric transport. The highest levels of HCB, PCBs, and PBDEs were found at a site impacted by forest fire during the sampling campaign. PMID:20235613

  17. Procedures manual for the recommended ARB (Air Resources Board) sized chemical sample method (cascade cyclones)

    SciTech Connect

    McCain, J.D.; Dawes, S.S.; Farthing, W.E.

    1986-05-01

    The report is Attachment No. 2 to the Final Report of ARB Contract A3-092-32 and provides a tutorial on the use of Cascade (Series) Cyclones to obtain size-fractionated particulate samples from industrial flue gases at stationary sources. The instrumentation and procedures described are designed to protect the purity of the collected samples so that post-test chemical analysis may be performed for organic and inorganic compounds, including instrumental analysis for trace elements. The instrumentation described collects bulk quantities for each of six size fractions over the range 10 to 0.4 micrometer diameter. The report describes the operating principles, calibration, and empirical modeling of small cyclone performance. It also discusses the preliminary calculations, operation, sample retrieval, and data analysis associated with the use of cyclones to obtain size-segregated samples and to measure particle-size distributions.

  18. Indoor air sampling and mutagenicity studies related to emissions from unvented coal combustion

    SciTech Connect

    Mumford, J.L.; Harris, D.B.; Williams, K.; Chuang, J.C.; Cooke, M.

    1986-07-01

    The purpose of the study is to develop sampling strategies and bioassay methods for indoor air in homes. The work reported here was conducted to prepare for a joint U.S.-China field study in Xuan Wei County, Yunnan Province, southern China, where the residents traditionally burn coal or wood for domestic cooking and heating without flue ventilation. These residents are exposed daily to high levels of combustion smoke and have unusually high lung cancer mortality rates, the women's rate the highest in China, and the men's rate among the highest. The paper reports the chemical and biological characterization of coal emissions from a simulated combustion laboratory.

  19. Trace Element Analysis of Biological Samples.

    ERIC Educational Resources Information Center

    Veillon, Claude

    1986-01-01

    Reviews background of atomic absorption spectrometry techniques. Discusses problems encountered and precautions to be taken in determining trace elements in the parts-per-billion concentration range and below. Concentrates on determining chromium in biological samples by graphite furnace atomic absorption. Considers other elements, matrices, and…

  20. COMPOSITE SAMPLING FOR SOIL VOC ANALYSIS

    EPA Science Inventory

    Data published by numerous researchers over the last decade demonstrate that there is a high degree of spatial variability in the measurement of volatile organic compounds (VOCs) in soil at contaminated waste sites. This phenomenon is confounded by the use of a small sample aliqu...

  1. AEROSOL SAMPLING AND ANALYSIS, PHOENIX, ARIZONA

    EPA Science Inventory

    An atmospheric sampling program was carried out in the greater Phoenix, Arizona metropolitan area in November, 1975. Objectives of the study were to measure aerosol mass flux through Phoenix and to characterize the aerosol according to particle type and size. The ultimate goal of...

  2. LABORATORY GUIDELINES FOR ANALYSIS OF BIOTERRORISM SAMPLES

    EPA Science Inventory

    After the attack on the World Trade Center on September 11, 2002, and the subsequent deaths associated with Bacillus anthracis spore contaminated mail, a worldwide need was apparent for increased laboratory capacity to safely analyze bioterrorism samples. The U.S. Department o...

  3. Analysis of large soil samples for actinides

    DOEpatents

    Maxwell, III; Sherrod L.

    2009-03-24

    A method of analyzing relatively large soil samples for actinides by employing a separation process that includes cerium fluoride precipitation for removing the soil matrix and precipitates plutonium, americium, and curium with cerium and hydrofluoric acid followed by separating these actinides using chromatography cartridges.

  4. Sampling and Analysis Plan for PUREX canyon vessel flushing

    SciTech Connect

    Villalobos, C.N.

    1995-03-01

    A sampling and analysis plan is necessary to provide direction for the sampling and analytical activities determined by the data quality objectives. This document defines the sampling and analysis necessary to support the deactivation of the Plutonium-Uranium Extraction (PUREX) facility vessels that are regulated pursuant to Washington Administrative Code 173-303.

  5. UMTRA water sampling and analysis plan, Tuba City, Arizona. Draft

    SciTech Connect

    Not Available

    1993-09-01

    The purpose of this document is to provide background, guidance, and justification for fiscal year (FY) 1994 water sampling activities for the uranium mil tailings site at Tuba City, Arizona. This sampling and analysis plan will form the basis for groundwater sampling and analysis work orders to be implemented in FY94.

  6. 40 CFR 92.129 - Exhaust sample analysis.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Exhaust sample analysis. 92.129... sample analysis. (a) The analyzer response may be read by automatic data collection (ADC) equipment such... is then applied to the analyzer's response to a sample of exhaust gas in order to compute the...

  7. 40 CFR 86.1340-90 - Exhaust sample analysis.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Exhaust sample analysis. 86.1340-90... § 86.1340-90 Exhaust sample analysis. (a) The analyzer response may be read by automatic data... final reading for the dilute exhaust sample bag. A single value representing the average...

  8. Analysis of vector wind change with respect to time for Vandenberg Air Force Base, California

    NASA Technical Reports Server (NTRS)

    Adelfang, S. I.

    1978-01-01

    A statistical analysis of the temporal variability of wind vectors at 1 km altitude intervals from 0 to 27 km altitude taken from a 10-year data sample of twice-daily rawinsode wind measurements over Vandenberg Air Force Base, California is presented.

  9. FORMAL UNCERTAINTY ANALYSIS OF A LAGRANGIAN PHOTOCHEMICAL AIR POLLUTION MODEL. (R824792)

    EPA Science Inventory

    This study applied Monte Carlo analysis with Latin
    hypercube sampling to evaluate the effects of uncertainty
    in air parcel trajectory paths, emissions, rate constants,
    deposition affinities, mixing heights, and atmospheric stability
    on predictions from a vertically...

  10. Contemporary-use pesticides in personal air samples during pregnancy and blood samples at delivery among urban minority mothers and newborns.

    PubMed Central

    Whyatt, Robin M; Barr, Dana B; Camann, David E; Kinney, Patrick L; Barr, John R; Andrews, Howard F; Hoepner, Lori A; Garfinkel, Robin; Hazi, Yair; Reyes, Andria; Ramirez, Judyth; Cosme, Yesenia; Perera, Frederica P

    2003-01-01

    We have measured 29 pesticides in plasma samples collected at birth between 1998 and 2001 from 230 mother and newborn pairs enrolled in the Columbia Center for Children's Environmental Health prospective cohort study. Our prior research has shown widespread pesticide use during pregnancy among this urban minority cohort from New York City. We also measured eight pesticides in 48-hr personal air samples collected from the mothers during pregnancy. The following seven pesticides were detected in 48-83% of plasma samples (range, 1-270 pg/g): the organophosphates chlorpyrifos and diazinon, the carbamates bendiocarb and 2-isopropoxyphenol (metabolite of propoxur), and the fungicides dicloran, phthalimide (metabolite of folpet and captan), and tetrahydrophthalimide (metabolite of captan and captafol). Maternal and cord plasma levels were similar and, except for phthalimide, were highly correlated (p < 0.001). Chlorpyrifos, diazinon, and propoxur were detected in 100% of personal air samples (range, 0.7-6,010 ng/m(3)). Diazinon and propoxur levels were significantly higher in the personal air of women reporting use of an exterminator, can sprays, and/or pest bombs during pregnancy compared with women reporting no pesticide use or use of lower toxicity methods only. A significant correlation was seen between personal air level of chlorpyrifos, diazinon, and propoxur and levels of these insecticides or their metabolites in plasma samples (maternal and/or cord, p < 0.05). The fungicide ortho-phenylphenol was also detected in 100% of air samples but was not measured in plasma. The remaining 22 pesticides were detected in 0-45% of air or plasma samples. Chlorpyrifos, diazinon, propoxur, and bendiocarb levels in air and/or plasma decreased significantly between 1998 and 2001. Findings indicate that pesticide exposures are frequent but decreasing and that the pesticides are readily transferred to the developing fetus during pregnancy. PMID:12727605

  11. Indoor air quality analysis based on Hadoop

    NASA Astrophysics Data System (ADS)

    Tuo, Wang; Yunhua, Sun; Song, Tian; Liang, Yu; Weihong, Cui

    2014-03-01

    The air of the office environment is our research object. The data of temperature, humidity, concentrations of carbon dioxide, carbon monoxide and ammonia are collected peer one to eight seconds by the sensor monitoring system. And all the data are stored in the Hbase database of Hadoop platform. With the help of HBase feature of column-oriented store and versioned (automatically add the time column), the time-series data sets are bulit based on the primary key Row-key and timestamp. The parallel computing programming model MapReduce is used to process millions of data collected by sensors. By analysing the changing trend of parameters' value at different time of the same day and at the same time of various dates, the impact of human factor and other factors on the room microenvironment is achieved according to the liquidity of the office staff. Moreover, the effective way to improve indoor air quality is proposed in the end of this paper.

  12. Estimation of sampling error uncertainties in observed surface air temperature change in China

    NASA Astrophysics Data System (ADS)

    Hua, Wei; Shen, Samuel S. P.; Weithmann, Alexander; Wang, Huijun

    2016-06-01

    This study examines the sampling error uncertainties in the monthly surface air temperature (SAT) change in China over recent decades, focusing on the uncertainties of gridded data, national averages, and linear trends. Results indicate that large sampling error variances appear at the station-sparse area of northern and western China with the maximum value exceeding 2.0 K2 while small sampling error variances are found at the station-dense area of southern and eastern China with most grid values being less than 0.05 K2. In general, the negative temperature existed in each month prior to the 1980s, and a warming in temperature began thereafter, which accelerated in the early and mid-1990s. The increasing trend in the SAT series was observed for each month of the year with the largest temperature increase and highest uncertainty of 0.51 ± 0.29 K (10 year)-1 occurring in February and the weakest trend and smallest uncertainty of 0.13 ± 0.07 K (10 year)-1 in August. The sampling error uncertainties in the national average annual mean SAT series are not sufficiently large to alter the conclusion of the persistent warming in China. In addition, the sampling error uncertainties in the SAT series show a clear variation compared with other uncertainty estimation methods, which is a plausible reason for the inconsistent variations between our estimate and other studies during this period.

  13. Extreme 13C depletion of CCl2F2 in firn air samples from NEEM, Greenland

    NASA Astrophysics Data System (ADS)

    Zuiderweg, A.; Holzinger, R.; Martinerie, P.; Schneider, R.; Kaiser, J.; Witrant, E.; Etheridge, D.; Petrenko, V.; Blunier, T.; Röckmann, T.

    2013-01-01

    A series of 12 high volume air samples collected from the S2 firn core during the North Greenland Eemian Ice Drilling (NEEM) 2009 campaign have been measured for mixing ratio and stable carbon isotope composition of the chlorofluorocarbon CFC-12 (CCl2F2). While the mixing ratio measurements compare favorably to other firn air studies, the isotope results show extreme 13C depletion at the deepest measurable depth (65 m), to values lower than δ13C = -80‰ vs. VPDB (the international stable carbon isotope scale), compared to present day surface tropospheric measurements near -40‰. Firn air modeling was used to interpret these measurements. Reconstructed atmospheric time series indicate even larger depletions (to -120‰) near 1950 AD, with subsequent rapid enrichment of the atmospheric reservoir of the compound to the present day value. Mass-balance calculations show that this change is likely to have been caused by a large change in the isotopic composition of anthropogenic CFC-12 emissions, probably due to technological advances in the CFC production process over the last 80 yr, though direct evidence is lacking.

  14. Extreme 13C depletion of CCl2F2 in firn air samples from NEEM, Greenland

    NASA Astrophysics Data System (ADS)

    Zuiderweg, A.; Holzinger, R.; Martinerie, P.; Schneider, R.; Kaiser, J.; Witrant, E.; Etheridge, D.; Rubino, M.; Petrenko, V.; Blunier, T.; Röckmann, T.

    2012-07-01

    A series of 12 high volume air samples collected from the S2 firn core during the North Greenland Eemian Ice Drilling (NEEM) 2009 campaign have been measured for mixing ratio and stable carbon isotope composition of the chlorofluorocarbon CFC-12 (CCl2F2). While the mixing ratio measurements compare favorably to other firn air studies, the isotope results show extreme 13C depletion at the deepest measurable depth (65 m), to values lower than δ13C = -80‰ vs. VPDB (the international stable carbon isotope scale), compared to present day surface tropospheric measurements near -40‰. Firn air modeling was used to interpret these measurements. Reconstructed atmospheric time series indicate even larger depletions (to -120‰) near 1950 AD, with subsequent rapid enrichment of the atmospheric reservoir of the compound to the present day value. Mass-balance calculations show that this change must have been caused by a large change in the isotopic composition of anthropogenic CFC-12 emissions, probably due to technological changes in the CFC production process over the last 80 yr. Propagating the mass-balance calculations into the future demonstrates that as emissions decrease to zero, isotopic fractionation by the stratospheric sinks will lead to continued 13C enrichment in atmospheric CFC-12.

  15. UMTRA water sampling and analysis plan, Green River, Utah

    SciTech Connect

    Papusch, R.

    1993-12-01

    The purpose of this water sampling and analysis plan (WSAP) is to provide a basis for groundwater and surface water sampling at the Green River Uranium Mill Tailing Remedial Action (UMTRA) Project site. This WSAP identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the monitoring locations.

  16. Bivariate conditional sampling of buoyancy flux during an intense cold-air outbreak

    NASA Technical Reports Server (NTRS)

    Chou, Shu-Hsien; Zimmerman, Jeffrey

    1989-01-01

    The joint frequency distribution technique was used to analyze buoyancy fluxes in the marine atmospheric boundary layer (MABL) for the cloud street regime noted during the Genesis of Atlantic Lows Experiment. It is found that for the lower half of the MABL, the buoyancy flux is mainly generated by the rising thermals and the sinking compensating ambient air, and is mainly consumed by the entrainment and detrainment of thermals, penetrative convection, and the entrainment from the MABL top. If the buoyancy flux is primarily driven by the temperature flux, these buoyancy-flux generating processes should be the same for the lower boundary layers over land and ocean. The results of the scale analysis of the buoyancy flux agree well with those obtained for mesoscale cellular convection during the Air-Mass Transformation Experiment.

  17. Cast Stone Oxidation Front Evaluation: Preliminary Results For Samples Exposed To Moist Air

    SciTech Connect

    Langton, C. A.; Almond, P. M.

    2013-11-26

    The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO{sub 4}{sup -} in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O{sub 4}{sup -}, which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate (Cr(VI) was used as a non-radioactive surrogate for pertechnetate, Tc(VII), in Cast Stone samples prepared with 5 M Simulant. Cast Stone spiked with pertechnetate was also prepared and tested. Depth discrete subsamples spiked with Cr were cut from Cast Stone exposed to Savannah River Site (SRS) outdoor ambient temperature fluctuations and moist air. Depth discrete subsamples spiked with Tc-99 were cut from Cast Stone exposed to laboratory ambient temperature fluctuations and moist air. Similar conditions are expected to be encountered in the Cast Stone curing container. The leachability of Cr and Tc-99 and the reduction capacities, measured by the Angus-Glasser method, were determined for each subsample as a function of depth from the exposed surface. The results obtained to date were focused on continued method development and are preliminary and apply to the sample composition and curing / exposure conditions described in this report. The

  18. Ozone data and mission sampling analysis

    NASA Technical Reports Server (NTRS)

    Robbins, J. L.

    1980-01-01

    A methodology was developed to analyze discrete data obtained from the global distribution of ozone. Statistical analysis techniques were applied to describe the distribution of data variance in terms of empirical orthogonal functions and components of spherical harmonic models. The effects of uneven data distribution and missing data were considered. Data fill based on the autocorrelation structure of the data is described. Computer coding of the analysis techniques is included.

  19. Venturi air-jet vacuum ejectors for high-volume atmospheric sampling on aircraft platforms

    NASA Technical Reports Server (NTRS)

    Hill, Gerald F.; Sachse, Glen W.; Young, Douglas C.; Wade, Larry O.; Burney, Lewis G.

    1992-01-01

    Documentation of the installation and use of venturi air-jet vacuum ejectors for high-volume atmospheric sampling on aircraft platforms is presented. Information on the types of venturis that are useful for meeting the pumping requirements of atmospheric-sampling experiments is also presented. A description of the configuration and installation of the venturi system vacuum line is included with details on the modifications that were made to adapt a venturi to the NASA Electra aircraft at GSFC, Wallops Flight Facility. Flight test results are given for several venturis with emphasis on applications to the Differential Absorption Carbon Monoxide Measurement (DACOM) system at LaRC. This is a source document for atmospheric scientists interested in using the venturi systems installed on the NASA Electra or adapting the technology to other aircraft.

  20. Ram-air sample collection device for a chemical warfare agent sensor

    DOEpatents

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  1. Air-to-air combat analysis - Review of differential-gaming approaches

    NASA Technical Reports Server (NTRS)

    Ardema, M. D.

    1981-01-01

    The problem of evaluating the combat performance of fighter/attack aircraft is discussed, and the mathematical nature of the problem is examined. The following approaches to air combat analysis are reviewed: (1) differential-turning differential game and (2) coplanar differential game. Selected numerical examples of these approaches are presented. The relative advantages and disadvantages of each are analyzed, and it is concluded that air combat analysis is an extremely difficult mathematical problem and that no one method of approach is best for all purposes. The paper concludes with a discussion of how the two approaches might be used in a complementary manner.

  2. Spectral analysis of lunar analogue samples

    NASA Astrophysics Data System (ADS)

    Offringa, Marloes; Foing, Bernard

    2016-04-01

    Analyses of samples derived from terrestrial analogue sites are used to study lunar processes in their geological context (Foing, Stoker, Ehrenfreund, 2011). For this study samples from the volcanic region of the Eifel, Germany collected during field campaigns (Foing et al., 2010), are analyzed with a variety of spectrometers. The aim is to obtain a database of analyzed samples that could be used as a reference for future in situ measurements. Equipment used in the laboratory consists of a Fourier Transform Infrared (FTIR) spectrometer, an X-Ray Fluorescence (XRF) spectrometer, a Raman laser spectrometer, as well as UV-VIS and NIR reflectance spectrometers. The Raman, UV-VIS and NIR are also used in combination with the EXoGeoLab mock-up lander during field campaigns (Foing, Stoker, Ehrenfreund, 2011). Calibration of the UV-VIS and NIR reflectance spectrometers is the main focus of this research in order to obtain the clearest spectra. The calibration of the UV-VIS and NIR reflectance spectrometers requires the use of a good light source as well as suitable optical fibers to create a signal that covers the widest range in wavelengths available. To eliminate noise towards the edges of this range, multiple measurements are averaged and data is processed by dividing the signal by reference spectra. Calibration of the devices by creating a new dark and reference spectra has to take place after every sample measurement. In this way we take into account changes that occur in the signal due to the eating of the devices during the measurements. Moreover, the integration time is adjusted to obtain a clear signal without leading to oversaturation in the reflectance spectrum. The typical integration times for the UV-VIS reflectance spectrometer vary between 1 - 18 s, depending on the amount of daylight during experiments. For the NIR reflectance spectrometer the integration time resulting in the best signals is approximately 150 ms in combination with a broad spectrum light

  3. Spatial analysis of the tuberculosis treatment dropout, Buenos Aires, Argentina

    PubMed Central

    Herrero, María Belén; Arrossi, Silvina; Ramos, Silvina; Braga, Jose Ueleres

    2015-01-01

    OBJECTIVE Identify spatial distribution patterns of the proportion of nonadherence to tuberculosis treatment and its associated factors. METHODS We conducted an ecological study based on secondary and primary data from municipalities of the metropolitan area of Buenos Aires, Argentina. An exploratory analysis of the characteristics of the area and the distributions of the cases included in the sample (proportion of nonadherence) was also carried out along with a multifactor analysis by linear regression. The variables related to the characteristics of the population, residences and families were analyzed. RESULTS Areas with higher proportion of the population without social security benefits (p = 0.007) and of households with unsatisfied basic needs had a higher risk of nonadherence (p = 0.032). In addition, the proportion of nonadherence was higher in areas with the highest proportion of households with no public transportation within 300 meters (p = 0.070). CONCLUSIONS We found a risk area for the nonadherence to treatment characterized by a population living in poverty, with precarious jobs and difficult access to public transportation. PMID:26270011

  4. Spatial analysis of the tuberculosis treatment dropout, Buenos Aires, Argentina.

    PubMed

    Herrero, María Belén; Arrossi, Silvina; Ramos, Silvina; Braga, Jose Ueleres

    2015-01-01

    OBJECTIVE Identify spatial distribution patterns of the proportion of nonadherence to tuberculosis treatment and its associated factors. METHODS We conducted an ecological study based on secondary and primary data from municipalities of the metropolitan area of Buenos Aires, Argentina. An exploratory analysis of the characteristics of the area and the distributions of the cases included in the sample (proportion of nonadherence) was also carried out along with a multifactor analysis by linear regression. The variables related to the characteristics of the population, residences and families were analyzed. RESULTS Areas with higher proportion of the population without social security benefits (p = 0.007) and of households with unsatisfied basic needs had a higher risk of nonadherence (p = 0.032). In addition, the proportion of nonadherence was higher in areas with the highest proportion of households with no public transportation within 300 meters (p = 0.070). CONCLUSIONS We found a risk area for the nonadherence to treatment characterized by a population living in poverty, with precarious jobs and difficult access to public transportation. PMID:26270011

  5. Optimal Media for Use in Air Sampling To Detect Cultivable Bacteria and Fungi in the Pharmacy

    PubMed Central

    Joseph, Riya Augustin; Le, Theresa V.; Trevino, Ernest A.; Schaeffer, M. Frances; Vance, Paula H.

    2013-01-01

    Current guidelines for air sampling for bacteria and fungi in compounding pharmacies require the use of a medium for each type of organism. U.S. Pharmacopeia (USP) chapter <797> (http://www.pbm.va.gov/linksotherresources/docs/USP797PharmaceuticalCompoundingSterileCompounding.pdf) calls for tryptic soy agar with polysorbate and lecithin (TSApl) for bacteria and malt extract agar (MEA) for fungi. In contrast, the Controlled Environment Testing Association (CETA), the professional organization for individuals who certify hoods and clean rooms, states in its 2012 certification application guide (http://www.cetainternational.org/reference/CAG-009v3.pdf?sid=1267) that a single-plate method is acceptable, implying that it is not always necessary to use an additional medium specifically for fungi. In this study, we reviewed 5.5 years of data from our laboratory to determine the utility of TSApl versus yeast malt extract agar (YMEA) for the isolation of fungi. Our findings, from 2,073 air samples obtained from compounding pharmacies, demonstrated that the YMEA yielded >2.5 times more fungal isolates than TSApl. PMID:23903551

  6. SO 2 sorption characteristics of air sampling filter media using a new laboratory test

    NASA Astrophysics Data System (ADS)

    Batterman, Stuart; Osak, Igor; Gelman, Charles

    A significant factor in the selection of filter media used for air sampling is the formation of artifacts due to the sorption of sulfur and nitrogen oxides on the filter. These artifacts can erroneously increase measured particulate concentrations. A technique is developed to measure the uptake of SO 2 and other gases and vapors on air sampling filter media. The static chamber technique features in-chamber measurements of SO 2 concentrations using FTIR spectrometry. The filter uptake, partition coefficient, and diffusion coefficient are estimated from the loss of gaseous SO 2 in the chamber. The technique provides rapid and precise results over a wide range of filter characteristics and avoids problems related to the extraction of target analytes from the filter. A total of 12 types of filters are evaluated, including glass fiber, Teflon-coated glass fiber, nylon, quartz fiber, Teflon, Supor, Nylasorb, and acrylic copolymer membranes. Results indicate that Teflon, quartz and acrylic copolymer filters have minimal sorption of SO 2 while quartz fiber, Supor and Nylasorb filters have high to moderate uptake of SO 2.

  7. Optimal media for use in air sampling to detect cultivable bacteria and fungi in the pharmacy.

    PubMed

    Weissfeld, Alice S; Joseph, Riya Augustin; Le, Theresa V; Trevino, Ernest A; Schaeffer, M Frances; Vance, Paula H

    2013-10-01

    Current guidelines for air sampling for bacteria and fungi in compounding pharmacies require the use of a medium for each type of organism. U.S. Pharmacopeia (USP) chapter <797> (http://www.pbm.va.gov/linksotherresources/docs/USP797PharmaceuticalCompoundingSterileCompounding.pdf) calls for tryptic soy agar with polysorbate and lecithin (TSApl) for bacteria and malt extract agar (MEA) for fungi. In contrast, the Controlled Environment Testing Association (CETA), the professional organization for individuals who certify hoods and clean rooms, states in its 2012 certification application guide (http://www.cetainternational.org/reference/CAG-009v3.pdf?sid=1267) that a single-plate method is acceptable, implying that it is not always necessary to use an additional medium specifically for fungi. In this study, we reviewed 5.5 years of data from our laboratory to determine the utility of TSApl versus yeast malt extract agar (YMEA) for the isolation of fungi. Our findings, from 2,073 air samples obtained from compounding pharmacies, demonstrated that the YMEA yielded >2.5 times more fungal isolates than TSApl. PMID:23903551

  8. Protocol Improvements for Low Concentration DNA-Based Bioaerosol Sampling and Analysis

    PubMed Central

    Ng, Chun Kiat; Miller, Dana; Cao, Bin

    2015-01-01

    Introduction As bioaerosol research attracts increasing attention, there is a need for additional efforts that focus on method development to deal with different environmental samples. Bioaerosol environmental samples typically have very low biomass concentrations in the air, which often leaves researchers with limited options in choosing the downstream analysis steps, especially when culture-independent methods are intended. Objectives This study investigates the impacts of three important factors that can influence the performance of culture-independent DNA-based analysis in dealing with bioaerosol environmental samples engaged in this study. The factors are: 1) enhanced high temperature sonication during DNA extraction; 2) effect of sampling duration on DNA recoverability; and 3) an alternative method for concentrating composite samples. In this study, DNA extracted from samples was analysed using the Qubit fluorometer (for direct total DNA measurement) and quantitative polymerase chain reaction (qPCR). Results and Findings The findings suggest that additional lysis from high temperature sonication is crucial: DNA yields from both high and low biomass samples increased up to 600% when the protocol included 30-min sonication at 65°C. Long air sampling duration on a filter media was shown to have a negative impact on DNA recoverability with up to 98% of DNA lost over a 20-h sampling period. Pooling DNA from separate samples during extraction was proven to be feasible with margins of error below 30%. PMID:26619279

  9. Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation

    NASA Technical Reports Server (NTRS)

    Sarrazin, P.; Chipera, S.; Bish, D.; Blake, D.; Feldman, S.; Vaniman, D.; Bryson, C.

    2004-01-01

    Sample preparation and sample handling are among the most critical operations associated with X-ray diffraction (XRD) analysis. These operations require attention in a laboratory environment, but they become a major constraint in the deployment of XRD instruments for robotic planetary exploration. We are developing a novel sample handling system that dramatically relaxes the constraints on sample preparation by allowing characterization of coarse-grained material that would normally be impossible to analyze with conventional powder-XRD techniques.

  10. Exomars 2018 Rover Pasteur Payload Sample Analysis

    NASA Astrophysics Data System (ADS)

    Debus, Andre; Bacher, M.; Ball, A.; Barcos, O.; Bethge, B.; Gaubert, F.; Haldemann, A.; Kminek, G.; Lindner, R.; Pacros, A.; Rohr, T.; Trautner, R.; Vago, J.

    The ExoMars programme is a joint ESA-NASA program having exobiology as one of the key science objectives. It is divided into 2 missions: the first mission is ESA-led with an ESA orbiter and an ESA Entry, Descent and Landing (EDL) demonstrator, launched in 2016 by NASA, and the second mission is NASA-led, launched in 2018 by NASA including an ESA rover and a NASA rover both deployed by a single NASA EDL system. For ESA, the ExoMars programme will demonstrate key flight and in situ enabling technologies in support of the European ambitions for future exploration missions, as outlined in the Aurora Declaration. The ExoMars 2018 ESA Rover will carry a comprehensive and coherent suite of analytical instruments dedicated to exobiology and geology research: the Pasteur Payload (PPL). This payload includes a selection of complementary instruments, having the following goals: to search for signs of past and present life on Mars and to investigate the water/geochemical environment as a function of depth in the shallow subsurface. The ExoMars Rover will travel several kilometres searching for sites warranting further investigation. The Rover includes a drill and a Sample Preparation and Distribution System which will be used to collect and analyse samples from within outcrops and from the subsurface. The Rover systems and instruments, in particular those located inside the Analytical Laboratory Drawer must meet many stringent requirements to be compatible with exobiologic investigations: the samples must be maintained in a cold and uncontaminated environment, requiring sterile and ultraclean preparation of the instruments, to preserve volatile materials and to avoid false positive results. The value of the coordinated observations suggests that a significant return on investment is to be expected from this complex development. We will present the challenges facing the ExoMars PPL, and the plans for sending a robust exobiology laboratory to Mars in 2018.

  11. Organic analysis of the returned lunar sample.

    PubMed

    Abell, P I; Draffan, G H; Eglinton, G; Hayes, J M; Maxwell, J R; Pillinger, C T

    1970-01-30

    Lunar fines have been examined for organic compounds by crushing, programmed heating, hydrofluoric acid etching, and solvent extraction. Products were examined by mass spectroscopy. A variety of small organic molecules, including methane and other hydrocarbons, accompanied the release of the rare gases when the sample was heated in a stepwise fashion to 900 degrees C under vacuum. Methane is more abundant (abundance on the order of 1 part per million) than argon in the matrix-entrapped gases liberated by hydrofluoric acid etching of lunar fines. Methane is also present in a dark portion of the gas-rich meteorite Kapoeta. PMID:17781581

  12. Analysis of a Suspected Drug Sample

    ERIC Educational Resources Information Center

    Schurter, Eric J.; Zook-Gerdau, Lois Anne; Szalay, Paul

    2011-01-01

    This general chemistry laboratory uses differences in solubility to separate a mixture of caffeine and aspirin while introducing the instrumental analysis methods of GCMS and FTIR. The drug mixture is separated by partitioning aspirin and caffeine between dichloromethane and aqueous base. TLC and reference standards are used to identify aspirin…

  13. Neutron activation analysis for antimetabolites. [in food samples

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Determination of metal ion contaminants in food samples is studied. A weighed quantity of each sample was digested in a concentrated mixture of nitric, hydrochloric and perchloric acids to affect complete solution of the food products. The samples were diluted with water and the pH adjusted according to the specific analysis performed. The samples were analyzed by neutron activation analysis, polarography, and atomic absorption spectrophotometry. The solid food samples were also analyzed by neutron activation analysis for increased sensitivity and lower levels of detectability. The results are presented in tabular form.

  14. ANASORB{reg_sign} 747 - A universal sorbent for air sampling?

    SciTech Connect

    Harper, M.

    1997-12-31

    A sorbent to be used for air sampling must meet certain performance criteria including sample background, capacity, stability, and recovery. Anasorb{sup R} 747 is a proprietary 20/40 mesh beaded active carbon prepared from raw materials with a very low ash content in a process which creates a regular pore structure. The background is very low for both inorganic and organic species, and the surface is more inert and less hydrophilic than coconut charcoal, while capacity is similar. The low catalytic activity of the surface means samples of many reactive compounds remain stable for longer periods. The sorbent is compatible with most solvent systems in use (e.g. carbon disulfide, methylene chloride, methanol, dimethyformamide). Anasorb 747 can be coated with chemicals for efficient adsorption of inorganic gases, which can be analyzed at very low levels because of low background interference. A large number of validated sampling methods use Anasorb 747, including methods from OSHA and NIOSH, corporate industrial hygiene laboratories, various branches of the EPA, and international agencies. These methods refer to around fifty different gases and vapors. Although this sorbent is not compatible with some compounds (e.g. low molecular weight aldehydes) it is quite close to being of universal application.

  15. Modified electrokinetic sample injection method in chromatography and electrophoresis analysis

    DOEpatents

    Davidson, J. Courtney; Balch, Joseph W.

    2001-01-01

    A sample injection method for horizontal configured multiple chromatography or electrophoresis units, each containing a number of separation/analysis channels, that enables efficient introduction of analyte samples. This method for loading when taken in conjunction with horizontal microchannels allows much reduced sample volumes and a means of sample stacking to greatly reduce the concentration of the sample. This reduction in the amount of sample can lead to great cost savings in sample preparation, particularly in massively parallel applications such as DNA sequencing. The essence of this method is in preparation of the input of the separation channel, the physical sample introduction, and subsequent removal of excess material. By this method, sample volumes of 100 nanoliter to 2 microliters have been used successfully, compared to the typical 5 microliters of sample required by the prior separation/analysis method.

  16. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    PubMed

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings. PMID:27569522

  17. RAZOR EX Anthrax Air Detection System for detection of Bacillus anthracis spores from aerosol collection samples: collaborative study.

    PubMed

    Hadfield, Ted; Ryan, Valorie; Spaulding, Usha K; Clemens, Kristine M; Ota, Irene M; Brunelle, Sharon L

    2013-01-01

    The RAZOR EX Anthrax Air Detection System was validated in a collaborative study for the detection of Bacillus anthracis in aerosol collection buffer. Phosphate-buffered saline was charged with 1 mg/mL standardized dust to simulate an authentic aerosol collection sample. The dust-charged buffer was spiked with either B. anthracis Ames at 2000 spores/mL or Bacillus cereus at 20 000 spores/mL. Twelve collaborators participated in the study, with four collaborators at each of three sites. Each collaborator tested 12 replicates of B. anthracis in dust-charged buffer and 12 replicates of B. cereus in dust-charged buffer. All samples sets were randomized and blind-coded. All collaborators produced valid data sets (no collaborators displayed systematic errors) and there was only one invalid data point. After unblinding, the analysis revealed a cross-collaborator probability of detection (CPOD) of 1.00 (144 positive results from 144 replicates, 95% confidence interval 0.975-1.00) for the B. anthracis samples and a CPOD of 0.00 (0 positive results from 143 replicates, 95% confidence interval 0.00-0.0262) for the B. cereus samples. These data meet the requirements of AOAC Standard Method Performance Requirement 2010.003, developed by the Stakeholder Panel on Agent Detection Assays. PMID:23767365

  18. Chemical and Trajectory Analysis of an Air Mass Plume from Asia

    NASA Astrophysics Data System (ADS)

    Guo, J. J.; Marrero, J. E.; Blake, D. R.

    2014-12-01

    Tracking the source of pollution events is important in understanding the transport of pollution plumes and impact on areas far from the source. Previous studies have shown that the rising contribution of Asian air pollution to the US has increased the number of days that pollution events exceed National Ambient Air Quality Standards (NAAQS). Whole air samples collected over the Edwards Air Force Base during a June 2014 NASA Student Airborne Research Program (SARP) flight exhibited enhancements in the concentrations of several compounds between 23-32 thousand feet. Chemical tracer analysis of these high altitude samples reveal that the air does not correspond to California emitted air. Chemical signatures in the plume, including high levels of OCS, chloroform, and methyl chloride, and low levels of methyl bromide, indicate that the plume was most heavily influence by coal combustion with contributions from biomass burning events from Asia. Low concentrations of ethene at the high altitude despite enhanced concentrations of ethane and ethyne suggest that this plume was aged. Further analysis of the plume using meteorological wind trajectories reveal that the plume had originated in China approximately 4-5 days prior. This is faster than results from previous studies that had found a Spring transport time of approximately 6 days.

  19. Total Particulate Matter Air Sampling Data (TEOM) from Los Alamos National Laboratory

    DOE Data Explorer

    LANL measures the total particulate mass concentration in the air on a routine basis as well as during incidents that may affect ambient air. The collected data is added to the Air Quality Index (AQI). AQI is an index for reporting daily air quality. It tells you how clean or polluted your air is, and what associated health effects might be a concern for you. The AQI focuses on health effects you may experience within a few hours or days after breathing polluted air. EPA calculates the AQI for five major air pollutants regulated by the Clean Air Act.

  20. COMPARISON OF SOLID ADSORBENT SAMPLING TECHNIQUES FOR VOLATILE ORGANIC COMPOUNDS IN AMBIENT AIR

    EPA Science Inventory

    The specific objective of the study was to compare the performance of three solid adsorbents (Tenax, an experimental polyimide resin, and Spherocarb) as well as cryogenic trapping/gas chromatography for sampling and analysis of a target list of volatile organic compounds in ambie...

  1. Analysis of toxic alkaloids in body samples.

    PubMed

    Beyer, Jochen; Drummer, Olaf H; Maurer, Hans H

    2009-03-10

    Many plants contain toxic alkaloids which may be dangerous to humans. Despite the large number of poisonous plants, cases of fatal plant poisonings are relatively rare. The frequencies of poisonings and the plants involved are often regionally specific. Plant poisonings can be aggregated into three categories: unintended ingestions, intended ingestions, and poisoning due to abuse of plant material. Unintended ingestions often occur in children or from a mix-up of plants and mushrooms in adults. Intended ingestions are common in homicides and suicides. Increasingly common is the abuse of plants for hallucinogenic reasons. Toxicological analysis of such alkaloids may help in diagnosis of poisoning or abuse cases. This review describes the toxic alkaloids aconitine, atropine, coniine, colchicine, cytisine, dimethyltryptamine, harmine, harmaline, ibogaine, kawain, mescaline, scopolamine, and taxine, which are often involved in fatal and non-fatal poisonings. The paper summarizes the symptoms of the intoxications and reviews the methods of detection of their toxic constituents in biological fluids. PMID:19147309

  2. Preparation, certification and interlaboratory analysis of workplace air filters spiked with high-fired beryllium oxide.

    PubMed

    Oatts, Thomas J; Hicks, Cheryl E; Adams, Amy R; Brisson, Michael J; Youmans-McDonald, Linda D; Hoover, Mark D; Ashley, Kevin

    2012-02-01

    Occupational sampling and analysis for multiple elements is generally approached using various approved methods from authoritative government sources such as the National Institute for Occupational Safety and Health (NIOSH), the Occupational Safety and Health Administration (OSHA) and the Environmental Protection Agency (EPA), as well as consensus standards bodies such as ASTM International. The constituents of a sample can exist as unidentified compounds requiring sample preparation to be chosen appropriately, as in the case of beryllium in the form of beryllium oxide (BeO). An interlaboratory study was performed to collect analytical data from volunteer laboratories to examine the effectiveness of methods currently in use for preparation and analysis of samples containing calcined BeO powder. NIST SRM(®) 1877 high-fired BeO powder (1100 to 1200 °C calcining temperature; count median primary particle diameter 0.12 μm) was used to spike air filter media as a representative form of beryllium particulate matter present in workplace sampling that is known to be resistant to dissolution. The BeO powder standard reference material was gravimetrically prepared in a suspension and deposited onto 37 mm mixed cellulose ester air filters at five different levels between 0.5 μg and 25 μg of Be (as BeO). Sample sets consisting of five BeO-spiked filters (in duplicate) and two blank filters, for a total of twelve unique air filter samples per set, were submitted as blind samples to each of 27 participating laboratories. Participants were instructed to follow their current process for sample preparation and utilize their normal analytical methods for processing samples containing substances of this nature. Laboratories using more than one sample preparation and analysis method were provided with more than one sample set. Results from 34 data sets ultimately received from the 27 volunteer laboratories were subjected to applicable statistical analyses. The observed

  3. Indoor air sampling and mutagenicity studies of emissions from unvented coal combustion

    SciTech Connect

    Mumford, J.L.; Harris, D.B.; Williams, K.; Chuang, J.C.; Cooke, M.

    1987-03-01

    To develop sampling strategies and bioassay protocols for indoor air containing emissions from coal combustion in homes of the rural Xuan Wei County in China, the authors developed a medium-volume sampler to collect the <10-..mu..m particles and semivolatile organics by a filter and an XAD-2 resin, respectively. A high-volume particulate sampler was used for comparison. The coal was burned under conditions that simulated the open-pit combustion that occurs in Xuan Wei. High-volume and medium-volume sampling yielded similar, high particulate concentrations 38-39 mg/m/sup 3/. Fifteen percent of the total extractable organic mass was collected in the XAD-2 resin, and the remaining 85% was retained in the filter. The polycyclic aromatic hydrocarbons found in the XAD were composed of four or fewer rings. In the Ames Salmonella assay, the XAD sample showed low mutagenic activity, and most of the mutagenic activity was found in the filter. The coal combustion emitted both direct- and indirect-acting mutagens, most of which were frameshift mutagens. 12 references, 2 figures, 3 tables.

  4. ENVIRONMENTAL SAMPLING AND ANALYSIS - GETTING IT RIGHT

    SciTech Connect

    CONNELL CW

    2008-01-22

    The Department of Energy's Hanford Site in southeastern Washington State was established in the 1940s as part of the Manhattan Project. Hanford's role was to produce weapons-grade nuclear material for defense, and by 1989, when the Site's mission changed from operations to cleanup, Hanford had produced more than 60 percent of the nation's plutonium. The legacy of Hanford's production years is enormous in terms of nuclear and hazardous waste, especially the 270 billion gallons of contaminated groundwater and the 5 million cubic yards of contaminated soil. Managing the contaminated soil and groundwater are particularly important because the Columbia River, the lifeblood of the northwest and the nation's eighth largest river, bounds the Site. Fluor Hanford's Soil & Groundwater Remediation Project (S&GRP) integrates all of the activities that deal with remediating and monitoring the groundwater across the Site. The S&GRP uses a detailed series of steps to record, track, and verify information. The Sample and Data Management (SDM) Process consists of 10 integrated steps that start with the data quality objectives process that establishes the mechanism for collecting the right information with the right people. The process ends with data quality assessment, which is used to ensure that all quantitative data (e.g., field screening, fixed laboratory) are the right type, and of adequate quality to support the decision-making process. Steps 3 through 10 of the process are production steps and are integrated electronically. The detailed plans, procedures, and systems used day-to-day by the SDM process require a high degree of accuracy and reliability. Tools must be incorporated into the processes that minimize errors. This paper discusses all of the elements of the SDM process in detail.

  5. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FIXED SITE INDOOR AND OUTDOOR AIR SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.12)

    EPA Science Inventory

    This SOP describes the procedures to set up, calibrate, initiate and terminate air sampling for persistent organic pollutants. This method is used to sample air, indoors and outdoors, at homes and at day care centers over a 48-hr period.

  6. Sample water removal method in volatile organic compound analysis based on diffusion through poly(vinyl fluoride) film.

    PubMed

    Beghi, Sandra; Guillot, Jean-Michel

    2006-09-15

    The humidity caught during air sampling or sample storage causes various problems during volatile organic compound (VOC) analysis and gives unreliable results. In this study, water vapour diffusion capacities through poly(vinyl fluoride) Tedlar, fluoroethylene propylene Teflon and Flex foil film were compared. A new approach to humidity removal has been tested for moderately polluted atmospheres. This approach consists in using the water vapour diffusion property of Tedlar film to remove humidity from bag samples containing a mixture of ten VOCs at 500 ppbv each in a 70% relative humidity atmosphere. The sampling bags were placed in a chamber flushed by a dry air stream at less than 5% relative humidity. After a few hours in the chamber, the samples in the Tedlar bags were dry (relative humidity <5%) and did not show significant VOC loss. This sample water removal (SWR) method is especially interesting as a pretreatment before air sampling on water sensitive adsorbents. PMID:16828784

  7. Air pollution and venous thrombosis: a meta-analysis

    PubMed Central

    Tang, Liang; Wang, Qing-Yun; Cheng, Zhi-Peng; Hu, Bei; Liu, Jing-Di; Hu, Yu

    2016-01-01

    Exposure to air pollution has been linked to cardiovascular and respiratory disorders. However, the effect of air pollution on venous thrombotic disorders is uncertain. We performed a meta-analysis to assess the association between air pollution and venous thrombosis. PubMed, Embase, EBM Reviews, Healthstar, Global Health, Nursing Database, and Web of Science were searched for citations on air pollutants (carbon monoxide, sulfur dioxide, nitrogen dioxide, ozone, and particulate matters) and venous thrombosis. Using a random-effects model, overall risk estimates were derived for each increment of 10 μg/m3 of pollutant concentration. Of the 485 in-depth reviewed studies, 8 citations, involving approximately 700,000 events, fulfilled the inclusion criteria. All the main air pollutants analyzed were not associated with an increased risk of venous thrombosis (OR = 1.005, 95% CI = 0.998–1.012 for PM2.5; OR = 0.995, 95% CI = 0.984–1.007 for PM10; OR = 1.006, 95% CI = 0.994–1.019 for NO2). Based on exposure period and thrombosis location, additional subgroup analyses provided results comparable with those of the overall analyses. There was no evidence of publication bias. Therefore, this meta analysis does not suggest the possible role of air pollution as risk factor for venous thrombosis in general population. PMID:27600652

  8. Monitoring and analysis of air quality in Riga

    NASA Astrophysics Data System (ADS)

    Ubelis, Arnolds; Leitass, Andris; Vitols, Maris

    1995-09-01

    Riga, the capital of Latvia is a city with nearly 900,000 inhabitants and various highly concentrated industries. Air pollution in Riga is a serious problem affecting health and damaging valuable buildings of historical importance, as acid rain and smog take their toll. Therefore the Air Quality Management System with significant assistance from Swedish Government and persistent efforts from Riga City Council was arranged in Riga. It contains INDIC AIRVIRO system which simulates and evaluates air pollution levels at various locations. It then processes the data in order to predict air quality based on a number of criteria and parameters, measured by OPSIS differential absorption instruments, as well as data from the Meteorological Service and results of episodic measurements. The analysis of the results provided by Riga Air Quality Management System for the first time allows us to start comprehensive supervision of troposphere physical, chemical, and photochemical processes in the air of Riga as well as to appreciate the influence of lcoal pollution and transboundary transfer. The report contains the actual results of this work and first attempts of analysis as well as overview about activities towards research and teaching in the fields of spectroscopy and photochemistry of polluted atmospheres.

  9. Air pollution and venous thrombosis: a meta-analysis.

    PubMed

    Tang, Liang; Wang, Qing-Yun; Cheng, Zhi-Peng; Hu, Bei; Liu, Jing-Di; Hu, Yu

    2016-01-01

    Exposure to air pollution has been linked to cardiovascular and respiratory disorders. However, the effect of air pollution on venous thrombotic disorders is uncertain. We performed a meta-analysis to assess the association between air pollution and venous thrombosis. PubMed, Embase, EBM Reviews, Healthstar, Global Health, Nursing Database, and Web of Science were searched for citations on air pollutants (carbon monoxide, sulfur dioxide, nitrogen dioxide, ozone, and particulate matters) and venous thrombosis. Using a random-effects model, overall risk estimates were derived for each increment of 10 μg/m(3) of pollutant concentration. Of the 485 in-depth reviewed studies, 8 citations, involving approximately 700,000 events, fulfilled the inclusion criteria. All the main air pollutants analyzed were not associated with an increased risk of venous thrombosis (OR = 1.005, 95% CI = 0.998-1.012 for PM2.5; OR = 0.995, 95% CI = 0.984-1.007 for PM10; OR = 1.006, 95% CI = 0.994-1.019 for NO2). Based on exposure period and thrombosis location, additional subgroup analyses provided results comparable with those of the overall analyses. There was no evidence of publication bias. Therefore, this meta analysis does not suggest the possible role of air pollution as risk factor for venous thrombosis in general population. PMID:27600652

  10. Modal analysis of PATHFINDER unmanned air vehicle

    SciTech Connect

    Woehrle, T.G.; Costerus, B.W.; Lee, C.L.

    1994-10-19

    An experimental modal analysis was performed on PATHFINDER, a 450-lb, 100-ft wing span, flying-wing-design aircraft powered by solar/electric motors. The aircraft was softly suspended and then excited using random input from a long-stroke shaker. Modal data was taken from 92 measurement locations on the aircraft using newly designed, lightweight, tri-axial accelerometers. A conventional PC-based data acquisition system provided data handling. Modal parameters were calculated, and animated mode shapes were produced using SMS STARStruct{trademark} Modal Analysis System software. The modal parameters will be used for validation of finite element models, optimum placement of onboard accelerometers during flight testing, and vibration isolation design of sensor platforms.

  11. X-RAY EMISSION ANALYSIS: SAMPLE LOSSES DURING EXCITATION

    EPA Science Inventory

    Many samples of atmospheric aerosols and biological materials containing volatile or unstable species are now being examined by X-ray emission analysis, and loss of these species by sample heating is a critical consideration. The amount of heat energy deposited in a sample by the...

  12. Solvent Selection for Pressurized Liquid Extraction of Polymeric Sorbents Used in Air Sampling

    PubMed Central

    Primbs, Toby; Genualdi, Susan; Simonich, Staci

    2014-01-01

    Pressurized liquid extraction (PLE) was evaluated as a method for extracting semivolatile organic compounds (SOCs) from air sampling media; including quartz fiber filter (QFF), polyurethane foam (PUF), and a polystyrene divinyl benzene copolymer (XAD-2). Hansen solubility parameter plots were used to aid in the PLE solvent selection in order to reduce both co-extraction of polyurethane and save time in evaluating solvent compatibility during the initial steps of method development. A PLE solvent composition of 75:25% hexane:acetone was chosen for PUF. The XAD-2 copolymer was not solubilized under the PLE conditions used. The average percent PLE recoveries (and percent relative standard deviations) of 63 SOCs, including polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and organochlorine, amide, triazine, thiocarbamate, and phosphorothioate pesticides, were 76.7 (6.2), 79.3 (8.1), and 93.4 (2.9) % for the QFF, PUF, and XAD-2, respectively. PMID:18220448

  13. Sampling of power plant stacks for air toxic emissions: Topical report for Phases 1 and 2

    SciTech Connect

    1995-02-21

    Under contract with the US Department of Energy (DE-AC22-92PCO0367), Pittsburgh Energy Technology Center, Radian Corporation has conducted a test program to collect and analyze size-fractionated stack gas particulate samples for selected inorganic hazardous air pollutants (HAPS). Specific goals of the program are (1) the collection of one-gram quantities of size-fractionated stack gas particulate matter for bulk (total) and surface chemical charactization, and (2) the determination of the relationship between particle size, bulk and surface (leachable) composition, and unit load. The information obtained from this program identifies the effects of unit load, particle size, and wet FGD system operation on the relative toxicological effects of exposure to particulate emissions.

  14. Analysis of hydrogen cyanide in air in a case of attempted cyanide poisoning.

    PubMed

    Magnusson, R; Nyholm, S; Åstot, C

    2012-10-10

    A 32-year-old man attempted to poison his ex-girlfriend with hydrogen cyanide by hiding the pesticide Uragan D2 in her car. During the police investigation, chemical analysis of the air inside the car was performed. Hydrogen cyanide was detected through on-site air analysis using a portable Fourier transform infrared (FTIR) spectroscopy gas analyzer and colorimetric gas detection tubes. Furthermore, impinger air-sampling was performed for off-site sample preparation and analysis by gas chromatography-mass spectrometry (GC-MS). All three independent techniques demonstrated the presence of hydrogen cyanide, at concentrations of 14-20 ppm. Owing to the high volatility of hydrogen cyanide, the temperature and the time since exposure have a substantial effect on the likelihood of detecting hydrogen cyanide at a crime scene. The prevailing conditions (closed space, low temperature) must have supported the preservation of HCN in the car thus enabling the identification even though the analysis was performed several days after the hydrogen cyanide source was removed. This paper demonstrates the applicability of combining on-site FTIR measurements and off-site GC-MS analysis of a crime scene in order to ensure fast detection as well as unambiguous identification for forensic purposes of hydrogen cyanide in air. PMID:22704552

  15. Spectral fingerprinting of polycyclic aromatic hydrocarbons in high-volume ambient air samples by constant energy synchronous luminescence spectroscopy

    USGS Publications Warehouse

    Kerkhoff, M.J.; Lee, T.M.; Allen, E.R.; Lundgren, D.A.; Winefordner, J.D.

    1985-01-01

    A high-volume sampler fitted with a glass-fiber filter and backed by polyurethane foam (PUF) was employed to collect airborne particulate and gas-phase polycylic aromatic hydrocarbons (PAHs) in ambient air. Samples were collected from four sources representing a range of environmental conditions: gasoline engine exhaust, diesel engine exhaust, air near a heavily traveled interstate site, and air from a moderately polluted urban site. Spectral fingerprints of the unseparated particulate and gas-phase samples were obtained by constant energy synchronous luminescence spectroscopy (CESLS). Five major PAHs in the gas-phase extracts were characterized and estimated. The compatibility of a high-volume sampling method using polyurethane foam coupled with CESLS detection is explored for use as a screening technique for PAHs in ambient air. ?? 1985 American Chemical Society.

  16. 40 CFR 86.1540 - Idle exhaust sample analysis.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the CVS sampling system is used, the analysis procedures for dilute CO and CO2 specified in 40 CFR part 1065 apply. Follow the raw CO2 analysis procedure specified in 40 CFR part 1065, subpart F, for the raw CO2 analyzer. (c) If the continuous raw exhaust sampling technique specified in 40 CFR...

  17. 40 CFR 86.1540 - Idle exhaust sample analysis.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the CVS sampling system is used, the analysis procedures for dilute CO and CO2 specified in 40 CFR part 1065 apply. Follow the raw CO2 analysis procedure specified in 40 CFR part 1065, subpart F, for the raw CO2 analyzer. (c) If the continuous raw exhaust sampling technique specified in 40 CFR...

  18. 40 CFR 86.1540 - Idle exhaust sample analysis.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CVS sampling system is used, the analysis procedures for dilute CO and CO2 specified in 40 CFR part 1065 apply. Follow the raw CO2 analysis procedure specified in 40 CFR part 1065, subpart F, for the raw CO2 analyzer. (c) If the continuous raw exhaust sampling technique specified in 40 CFR part 1065...

  19. 40 CFR 600.112-78 - Exhaust sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Exhaust sample analysis. 600.112-78... FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy Regulations for 1978 and Later Model Year Automobiles-Test Procedures § 600.112-78 Exhaust sample analysis. The...

  20. 40 CFR 600.112-08 - Exhaust sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Exhaust sample analysis. 600.112-08... FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy Regulations for 1978 and Later Model Year Automobiles-Test Procedures § 600.112-08 Exhaust sample analysis. The...