Sample records for air sample collected

  1. Airborne detection and quantification of swine influenza a virus in air samples collected inside, outside and downwind from swine barns.

    PubMed

    Corzo, Cesar A; Culhane, Marie; Dee, Scott; Morrison, Robert B; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m³ of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m³ of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m³. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions.

  2. Airborne Detection and Quantification of Swine Influenza A Virus in Air Samples Collected Inside, Outside and Downwind from Swine Barns

    PubMed Central

    Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164

  3. Development and testing of a portable wind sensitive directional air sampler

    NASA Technical Reports Server (NTRS)

    Deyo, J.; Toma, J.; King, R. B.

    1975-01-01

    A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.

  4. Molecular detection of airborne Coccidioides in Tucson, Arizona

    USGS Publications Warehouse

    Chow, Nancy A.; Griffin, Dale W.; Barker, Bridget M.; Loparev, Vladimir N.; Litvintseva, Anastasia P.

    2016-01-01

    Environmental surveillance of the soil-dwelling fungus Coccidioides is essential for the prevention of Valley fever, a disease primarily caused by inhalation of the arthroconidia. Methods for collecting and detectingCoccidioides in soil samples are currently in use by several laboratories; however, a method utilizing current air sampling technologies has not been formally demonstrated for the capture of airborne arthroconidia. In this study, we collected air/dust samples at two sites (Site A and Site B) in the endemic region of Tucson, Arizona, and tested a variety of air samplers and membrane matrices. We then employed a single-tube nested qPCR assay for molecular detection. At both sites, numerous soil samples (n = 10 at Site A and n = 24 at Site B) were collected and Coccidioides was detected in two samples (20%) at Site A and in eight samples (33%) at Site B. Of the 25 air/dust samples collected at both sites using five different air sampling methods, we detected Coccidioides in three samples from site B. All three samples were collected using a high-volume sampler with glass-fiber filters. In this report, we describe these methods and propose the use of these air sampling and molecular detection strategies for environmental surveillance of Coccidioides.

  5. Molecular comparison of the sampling efficiency of four types of airborne bacterial samplers.

    PubMed

    Li, Kejun

    2011-11-15

    In the present study, indoor and outdoor air samples were collected using four types of air samplers often used for airborne bacterial sampling. These air samplers included two solid impactors (BioStage and RCS), one liquid impinger (BioSampler), and one filter sampler with two kinds of filters (a gelatin and a cellulose acetate filter). The collected air samples were further processed to analyze the diversity and abundance of culturable bacteria and total bacteria through standard culture techniques, denaturing gradient gel electrophoresis (DGGE) fingerprinting and quantitative polymerase chain reaction (qPCR) analysis. The DGGE analysis indicated that the air samples collected using the BioStage and RCS samplers have higher culturable bacterial diversity, whereas the samples collected using the BioSampler and the cellulose acetate filter sampler have higher total bacterial diversity. To obtain more information on the sampled bacteria, some gel bands were excised and sequenced. In terms of sampling efficiency, results from the qPCR tests indicated that the collected total bacterial concentration was higher in samples collected using the BioSampler and the cellulose acetate filter sampler. In conclusion, the sampling bias and efficiency of four kinds of air sampling systems were compared in the present study and the two solid impactors were concluded to be comparatively efficient for culturable bacterial sampling, whereas the liquid impactor and the cellulose acetate filter sampler were efficient for total bacterial sampling. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Occurrence of pesticides in rain and air in urban and agricultural areas of Mississippi, April-September 1995.

    PubMed

    Coupe, R H; Manning, M A; Foreman, W T; Goolsby, D A; Majewski, M S

    2000-04-05

    In April 1995, the US Geological Survey began a study to determine the occurrence and temporal distribution of 49 pesticides and pesticide metabolites in air and rain samples from an urban and an agricultural sampling site in Mississippi. The study was a joint effort between the National Water-Quality Assessment and the Toxic Substances Programs and was part of a larger study examining the occurrence and temporal distribution of pesticides in air and rain in the Mississippi River basin. Concurrent high-volume air and wet-only deposition samples were collected weekly. The air samplers consisted of a glass-fiber filter to collect particles and tandem polyurethane foam plugs to collect gas-phase pesticides. Every rain and air sample collected from the urban and agricultural sites had detectable levels of multiple pesticides. The magnitude of the total concentration was 5-10 times higher at the agricultural site as compared to the urban site. The pesticide with the highest concentration in rain at both sites was methyl parathion. The pesticide with the highest concentration in the air samples from the agricultural site was also methyl parathion, but from the urban site the highest concentration was diazinon followed closely by chlorpyrifos. More than two decades since p,p'-DDT was banned from use in the United States, p,p'-DDE, a metabolite of p,p'-DDT, was detected in every air sample collected from the agricultural site and in more than half of the air samples from the urban site.

  7. Occurrence of pesticides in rain and air in urban and agricultural areas of Mississippi, April-September 1995

    USGS Publications Warehouse

    Coupe, R.H.; Manning, M.A.; Foreman, W.T.; Goolsby, D.A.; Majewski, M.S.

    2000-01-01

    In April 1995, the US Geological Survey began a study to determine the occurrence and temporal distribution of 49 pesticides and pesticide metabolites in air and rain samples from an urban and an agricultural sampling site in Mississippi. The study was a joint effort between the National Water-Quality Assessment and the Toxic Substances Programs and was part of a larger study examining the occurrence and temporal distribution of pesticides in air and rain in the Mississippi River basin. Concurrent high-volume air and wet-only deposition samples were collected weekly. The air samplers consisted of a glass-fiber filter to collect particles and tandem polyurethane foam plugs to collect gas-phase pesticides. Every rain and air sample collected from the urban and agricultural sites had detectable levels of multiple pesticides. The magnitude of the total concentration was 5-10 times higher at the agricultural site as compared to the urban site. The pesticide with the highest concentration in rain at both sites was methyl parathion. The pesticide with the highest concentration in the air samples from the agricultural site was also methyl parathion, but from the urban site the highest concentration was diazinon followed closely by chlorpyrifos. More than two decades since p,p'-DDT was banned from use in the United States, p,p'-DDE, a metabolite of p,p'-DDT, was detected in every air sample collected from the agricultural site and in more than half of the air samples from the urban site. Copyright (C) 2000 Elsevier Science B.V.

  8. Biobriefcase aerosol collector

    DOEpatents

    Bell, Perry M [Tracy, CA; Christian, Allen T [Madison, WI; Bailey, Christopher G [Pleasanton, CA; Willis, Ladona [Manteca, CA; Masquelier, Donald A [Tracy, CA; Nasarabadi, Shanavaz L [Livermore, CA

    2009-09-22

    A system for sampling air and collecting particles entrained in the air that potentially include bioagents. The system comprises providing a receiving surface, directing a liquid to the receiving surface and producing a liquid surface. Collecting samples of the air and directing the samples of air so that the samples of air with particles entrained in the air impact the liquid surface. The particles potentially including bioagents become captured in the liquid. The air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid but cause minor turbulence. The liquid surface has a surface tension and the collector samples the air and directs the air to the liquid surface so that the air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid, but cause minor turbulence on the surface resulting in insignificant evaporation of the liquid.

  9. Biobriefcase aerosol collector heater

    DOEpatents

    Bell, Perry M [Tracy, CA; Christian, Allen T [Madison, WI; Bailey, Christopher G [Pleasanton, CA; Willis, Ladona [Manteca, CA; Masquelier, Donald A [Tracy, CA; Nasarabadi, Shanavaz L [Livermore, CA

    2009-03-17

    A system for sampling air and collecting particles potentially including bioagents entrained in the air for detection. The system comprises collecting a sample of the air with the particles entrained in the air, directing the sample to a receiving surface, directing a liquid to the receiving surface thereby producing a liquid surface, wherein the particles potentially including bioagents become captured in the liquid, and heating the liquid wherein the particles potentially including bioagents become heated to lysis the bioagents.

  10. Legionnaires' Disease Bacteria in power plant cooling systems: downtime report. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyndall, R.L.; Solomon, J.A.; Christensen, S.W.

    1985-04-01

    Legionnaires' Disease Bacteria (Legionella) are a normal part of the aquatic community that, when aerosolized, can be pathogenic to man. The downtime study was designed to determine the degree to which Legionella populations are aerosolized during cleaning and maintenance operations in a closed-cycle steam-electric power plant. Both high-volume and impinger air samples were collected prior to and during downtime operations. Emphasis was placed on sampling inside or adjacent to water boxes, condensers, and cooling towers. Control air samples were taken upwind from the plant site. Water and sludge samples were also collected at various locations. In the laboratory, the concentrationsmore » of Groups A, B, and C Legionella were determined using the direct fluorescent antibody method. All positive air samples, and other selected air samples, were injected into guinea pigs to detect infectious Legionella. Legionella could be detected in only 12 of the 126 air samples collected. These were predominantly Group A Legionella (L. pneumophila, serogroups 1 to 6). All 12 positive samples had been collected in the vicinity of water boxes, condensers, detention ponds, and cooling towers during downtime operations where aerosolization of Legionella populations would be expected. None of the air samples yielded infectious Legionella when injected into guinea pigs. Detection of Legionella in air samples taken during downtime was significantly more likely than detection during normal operating conditions (p <0.01). 13 refs., 4 figs., 10 tabs.« less

  11. A STRINGENT COMPARISON OF SAMPLING AND ANALYSIS METHODS FOR VOCS IN AMBIENT AIR

    EPA Science Inventory

    A carefully designed study was conducted during the summer of 1998 to simultaneously collect samples of ambient air by canisters and compare the analysis results to direct sorbent preconcentration results taken at the time of sample collection. A total of 32 1-h sample sets we...

  12. Nickel and vanadium in air particulates at Dhahran (Saudi Arabia) during and after the Kuwait oil fires

    NASA Astrophysics Data System (ADS)

    Sadiq, M.; Mian, A. A.

    Air particulates, both the total suspended (TSP) and inhalable (PM 10, smaller than 10 microns in size), were collected during and after the Kuwait oil fires (from March 1991 to July 1992) using Hi-Vol samplers. These samples were wet-digested at 120°C in an aqua regia and perchloric acids mixture for 3 h. Air particulate samples collected in 1982 at the same location were prepared similarly. Concentrations of nickel and vanadium were determined in the aliquot samples using an inductively coupled argon plasma analyser (ICAP). The monthly mean concentrations of nickel and vanadium, on volume basis, increased rapidly from March to June and decreased sharply during July-August in 1991. The minimum mean concentrations of these elements were found in the particulate samples collected in December 1991 which gradually increased through May 1992. Like 1991, nickel and vanadium concentrations in the air particulates spiked in June and decreased again in July 1992. This distribution pattern of nickel and vanadium concentrations was similar to that of the predominant wind from the north (Kuwait). In general, concentrations of these elements were higher in the air particulates collected during April-July 1991 as compared with those collected in 1992 during the same period. The TSPs contained higher concentrations of nickel and vanadium than those found in the PM 10 samples. However, this trend was reversed when concentrations of nickel and vanadium, on were expressed on particulate weight basis. The monthly mean concentrations of nickel and vanadium, on weight basis, decreased gradually through 1991 and increased slightly from March to July 1992. Concentrations of these elements were significantly higher in the air particulate samples collected in 1991 than those samples collected during 1982 at the same location. The data of this study suggest a contribution of the Kuwait oil fires in elevating nickel and vanadium concentrations in the air particulates at Dhahran during April-July 1991. Concentrations of these elements were largely below their proposed limits in the ambient air (for nickel-50 μg m -3, air; for vanadium—1 μg m -3 air). It is, therefore, anticipated that concentrations of nickel and vanadium in the air particulate samples were not a health concern during Kuwait oil fires at Dhahran, Saudi Arabia.

  13. Legionnaires' disease bacteria in power plant cooling systems: downtime report. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyndall, R.L.; Solomon, J.A.; Christensen, S.W.

    1985-11-01

    Legionnaires' disease bacteria (Legionella) are a normal part of the aquatic community that, when aerosolized, can be pathogenic to man. The downtime study was designed to determine the degree to which Legionella populations are aerosolized during cleaning and maintenance operations in a closed-cycle steam-electric power plant. Both high-volume and impinger air samples were collected prior to and during downtime operations. Emphasis was placed on sampling inside or adjacent to water boxes, condensers, and cooling towers. Control air samples were taken upwind from the plant site. Water and sludge samples were also collected at various locations. In the laboratory, the concentrationsmore » of Legionella were determined using the direct fluorescent antibody method. All positive air samples, and other selected air samples, were injected into guinea pigs to detect infectious Legionella. Legionella could be detected in only 12 of the 127 air samples collected. These were predominantly L. pneumophila, serogroups 1-6. In contrast to the air samples, most of the water and sludge samples were positive for Legionella, again predominantly L. pneumophila, serogroups 1-6. The highest Legionella concentrations were found in sludge samples associated with condenser tube cleaning. Among the water samples, the highest Legionella concentrations were found in cooling towers, immediately after the tower basins were cleaned and refilled, and in condenser tubes. Two of the three cooling tower water samples collected prior to downtime operations were infectious for guinea pigs. 16 refs., 4 figs., 11 tabs.« less

  14. Collection and Analysis of Firn Air from the South Pole, 2001

    NASA Astrophysics Data System (ADS)

    Butler, J. H.; Montzka, S. A.; Battle, M.; Clarke, A. D.; Mondeel, D. J.; Lind, J. A.; Hall, B. D.; Elkins, J. W.

    2001-12-01

    In January 2001, we collected an archive of 20th century air from the firn (snowpack) at the South Pole. Samples were collected into separate pairs of 3L glass flasks for measurements of O2/N2 (Bowdoin/Princeton) and carbon cycle gases (CMDL); individual 3L stainless steel and glass flasks for measurements of halocarbons, N2O, SF6, and COS; large (33L) stainless steel canisters for maintaining an archive of air for future analyses; and a few canisters each for measurement of 14CH4 (NIWA/CSIRO) and very low-level analyses of SF6 (SIO). Although it was hoped to obtain air dating back to the turn of the century, the analyses suggest that the earliest date was 1925 for CO2 and the mid- to late teens for heavier gases such as methyl bromide or methyl chloride. This talk will compare the analyses of halocarbons in these recently collected samples to those of air in flasks sampled at the South Pole in 1995. We also will present some results for compounds not measured in the 1995 South Pole samples owing to a paucity of air. Measurements made of the same gases in the firn air at both ends of this six-year interval, along with real-time atmospheric measurements of the same gases, are useful in evaluating assumptions about diffusion in the firn and may allow for the direct calculation of diffusion coefficients at low temperatures. This, in turn, would improve age estimates for firn air samples. New measurements will add to our existing histories established for the 20th century from analyses of firn air samples collected in both Greenland and Antarctica.

  15. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, Katharine H.

    1990-01-01

    An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry.

  16. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1987-12-10

    An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  17. 78 FR 37219 - Information Collection Request Submitted to OMB for Review and Approval; Comment Request; RadNet...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-20

    ... restricted by statute. FOR FURTHER INFORMATION CONTACT: Charles M. Petko, Office of Radiation and Indoor Air... national network of stations collecting sampling media that include air, precipitation, drinking water, and milk. Samples are sent to EPA's National Air and Radiation Environmental Laboratory (NAREL) in...

  18. Fogwater Chemistry and Air Quality in the Texas-Louisiana Gulf Coast Corridor

    NASA Astrophysics Data System (ADS)

    Kommalapati, R. R.; Raja, S.; Ravikrishna, R.; Murugesan, K.; Collett, J. L.; Valsaraj, K.

    2007-05-01

    The presence of fog water in polluted atmosphere can influence atmospheric chemistry and air quality. The study of interactions between fog water and atmospheric gases and aerosols are very important in understanding the atmospheric fate of the pollutants. In this Study several air samples and fogwater samples were collected in the heavily industrialized area of Gulf Coast corridor( Houston, TX and Baton Rouge, LA). A total of 32 fogwater samples were collected, comprising of nine fog events in Baton Rouge (Nov 2004 to Feb 2005) and two fog events in Houston (Feb, 2006), during the fog sampling campaigns. These samples were analyzed for pH, total and dissolved carbon, major inorganic ions, organic acids, and aromatics, aldehydes, VOCs, and linear alkanes organic compounds. Fogwater samples collected in Houston show clear influence of marine and anthropogenic environment, while Baton Rouge samples reveal a relatively less polluted environment. Also, a time series observation of air samples indicated that fog event at the monitoring site impacted the air concentrations of the pollutants. This is attributed to presence of surface active organic matter in fog water.

  19. Comparison of the Results of Studies of Air Pollution Fungi Using the SAS Super 100, MAS 100, and Air IDEAL.

    PubMed

    Łukaszuk, Cecylia; Krajewska-Kułak, Elżbieta; Guzowski, Andrzej; Kułak, Wojciech; Kraszyńska, Bogumiła

    2017-07-20

    Although several air sampling devices for identifying and enumerating airborne microorganisms are commercially available, each poses some limitations. The aim of this study was to evaluate air pollution fungi using three such samplers: SAS Super 100, Microbiological Air Sampler (MAS) 100, and Air IDEAL. Mycological air was taken from the cellars of a 17th-century church in Siemiatycze, Poland, and the nearby outdoor environment. With samplers placed 1.5 m above the floor, microbial flora in air samples collected inside and outside the cellar were detected. The number of colony-forming units (CFU) of fungi obtained with the three samplers from the cellars and outdoor environment differed; the most CFU were obtained with the Air IDEAL and the least with the SAS Super 100. Significant differences emerged in CFUs collected from air samples with the MAS 100 and SAS Super 100, on the one hand, and the SAS Super 100 and Air IDEAL, on the other. Otherwise, results among the samplers were different. More Cladosporium species were collected with the MAS 100 sampler, whereas more Fusarium and Aspergillus species were collected with the Air IDEAL sampler. Significant differences among CFU/m³ values among the tested sites depended on the sampler used.

  20. Comparison of indoor air sampling and dust collection methods for fungal exposure assessment using quantitative PCR.

    PubMed

    Cox, Jennie; Indugula, Reshmi; Vesper, Stephen; Zhu, Zheng; Jandarov, Roman; Reponen, Tiina

    2017-10-18

    Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample collected with a Button™ inhalable aerosol sampler and four types of dust samples: a vacuumed floor dust sample, newly settled dust collected for four weeks onto two types of electrostatic dust cloths (EDCs) in trays, and a wipe sample of dust from above floor surfaces. The samples were obtained in the bedrooms of asthmatic children (n = 14). Quantitative polymerase chain reaction (qPCR) was used to analyze the dust and air samples for the 36 fungal species that make up the Environmental Relative Moldiness Index (ERMI). The results from the samples were compared by four matrices: total concentration of fungal cells, concentration of fungal species associated with indoor environments, concentration of fungal species associated with outdoor environments, and ERMI values (or ERMI-like values for air samples). The ERMI values for the dust samples and the ERMI-like values for the 48 hour air samples were not significantly different. The total cell concentrations of the 36 species obtained with the four dust collection methods correlated significantly (r = 0.64-0.79, p < 0.05), with the exception of the vacuumed floor dust and newly settled dust. In addition, fungal cell concentrations of indoor associated species correlated well between all four dust sampling methods (r = 0.68-0.86, p < 0.01). No correlation was found between the fungal concentrations in the air and dust samples primarily because of differences in concentrations of Cladosporium cladosporioides Type 1 and Epicoccum nigrum. A representative type of dust sample and a 48 hour air sample might both provide useful information about fungal exposures.

  1. Helium in soil gases of the Roosevelt Hot Springs Known Geothermal Resource Ares, Beaver County, Utah

    USGS Publications Warehouse

    Hinkle, M.E.; Denton, E.H.; Bigelow, R.C.; Turner, R.L.

    1978-01-01

    Soil samples were collected in two parallel traverses across the Dome fault zone of the Roosevelt Hot Springs Known Geothermal Resource Area. The samples were sealed in air-tight aluminum cans, and the soil gas was allowed to equilibrate with the atmospheric air in the cans. Gas from the cans was analyzed by mass spectrometry. Samples collected over faults contained anomalously high concentrations of helium. Samples collected close to a geothermal well 884 m deep contained more helium than samples collected near another geothermal well 1370 m deep.

  2. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1990-05-22

    An inertial impactor is designed which is to be used in an air sampling device for collection of respirable size particles in ambient air. The device may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  3. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Air sampling. 61.34 Section 61.34... sampling. (a) Stationary sources subject to § 61.32(b) shall locate air sampling sites in accordance with a... concentrations calculated within 30 days after filters are collected. Records of concentrations at all sampling...

  4. Determination of radionuclide concentrations in ground level air using the ASS-500 high volume sampler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frenzel, E.; Arnold, D.; Wershofen, H.

    1996-06-01

    A method for determination of radionuclide concentrations in air aerosol samples collected by the high volume aerosol sampler ASS-500 was elaborated. The aerosol sampling station ASS-500 is a Stand alone, all-weather proofed instrument. It is designed for representative sampling of airborne radionuclides from ground level air at a height of about 1.5 m above ground level. The ASS-500 station enables continuous air monitoring both normal and emergency Situations. The collection of aerosols on the Petrianov FPP-15-1.5 type filter out of an air volume of about 100,000 m{sup 3} (sampling period 1 wk) or of about 250,000 m{sup 3} (sampling periodmore » 3 wk) admits accurate spectrometric low level measurements of natural and artificial radionuclides. The achieved detection limit is 0.5 {mu}Bq m{sup -3} and 0.2 {mu}Bq m{sup -3} for {sup 137}Cs, respectively. A new developed air flow Meter system allows to enhance the collected air volume to about 150,000 m{sup 3} per week and lowers the detection limit to <0.4 {mu}Bq m{sup -3} for {sup 137}Cs for weekly collected aerosol samples. In Poland the CLOR uses 9 Stations ASS-500 at different sites as atmospheric radioactivity control system. On the basis of spectrometric measurements of natural and artificial radionuclides in the collected aerosol samples at the different sites, CLOR establishes a weekly report about the radiological situation at Poland for responsible authorities. The very low achievable detection limit of the Station ASS-500 due 10 the high air flow fate and the long possible sampling period were the key argument for other government radiation protection authorities in Europe to introduce the Station ASS-500 into their low level radionuclide atmospheric monitoring programs (Austria, Belarus, France, Germany, Iceland, Spain, Switzerland, Ukraine).« less

  5. HIGH VOLUME INJECTION FOR GCMS ANALYSIS OF PARTICULATE ORGANIC SPECIES IN AMBIENT AIR

    EPA Science Inventory

    Detection of organic species in ambient particulate matter typically requires large air sample volumes, frequently achieved by grouping samples into monthly composites. Decreasing the volume of air sample required would allow shorter collection times and more convenient sample c...

  6. Atmospheric Methane Mixing Ratios--The NOAA/CMDL Global Cooperative Air Sampling Network\\, 1983-1993

    DOE Data Explorer

    Dlugokencky, E. J. [National Oceanic and Atmospheric Administration, Boulder, Colorado (USA); Lang, P. M. [National Oceanic and Atmospheric Administration, Boulder, Colorado (USA); Masarie, K. A. [National Oceanic and Atmospheric Administration, Boulder, Colorado (USA); Steele, L. P. [Commonwealth Scientific and Industrial Research Organisation, Aspendale, Victoria, Australia

    1994-01-01

    This data base presents atmospheric methane (CH4) mixing ratios from flask air samples collected over the period 1983-1993 by the National Oceanic and Atmospheric Administration, Climate Monitoring and Diagnostics Laboratory's (NOAA/CMDL's) global cooperative air sampling network. Air samples were collected approximately once per week at 44 fixed sites (37 of which were still active at the end of 1993). Samples were also collected at 5 degree latitude intervals along shipboard cruise tracks in the Pacific Ocean between North America and New Zealand (or Australia) and at 3 degree latitude intervals along cruise tracks in the South China Sea between Singapore and Hong Kong. The shipboard measurements were made approximately every 3 weeks per latitude zone by each of two ships in the Pacific Ocean and approximately once every week per latitude zone in the South China Sea. All samples were analyzed for CH4 at the NOAA/CMDL laboratory in Boulder, Colorado, by gas chromatography with flame ionization detection, and each aliquot was referenced to the NOAA/CMDL methane standard scale. In addition to providing the complete set of atmospheric CH4 measurements from flask air samples collected at the NOAA/CMDL network sites, this data base also includes files which list monthly mean mixing ratios derived from the individual flask air measurements. These monthly summary data are available for 35 of the fixed sites and 21 of the shipboard sampling sites.

  7. Carbon-13 Isotopic Abundance and Concentration of Atmospheric Methane for Background Air in the Southern and Northern Hemispheres from 1978 to 1989 (NDP-049)

    DOE Data Explorer

    Stevens, C. M. [Chemical Technology Division, Argonne National Laboratory, Argonne, Illinois (USA)

    2012-01-01

    This data package presents atmospheric CH4 concentration and 13C isotopic abundance data derived from air samples collected over the period 1978-1989 at globally distributed clean-air sites. The data set comprises 201 records, 166 from the Northern Hemisphere and 35 from the Southern Hemisphere. The air samples were collected mostly in rural or marine locations remote from large sources of CH4 and are considered representative of tropospheric background conditions. The air samples were processed by isolation of CH4 from air and conversion to CO2 for isotopic analysis by isotope ratio mass spectrometry. These data represent one of the earliest records of 13C isotopic yy!measurements for atmospheric methane and have been used to refine estimates of CH4 emissions, calculate annual growth rates of emissions from changing sources, and provide evidence for changes in the rate of atmospheric removal of CH4. The data records consist of sample collection date; number of samples combined for analysis; sampling location; analysis date; CH4 concentration; 13C isotopic abundance; and flag codes to indicate outliers, repeated analyses, and other information.

  8. Detection of the urban release of a bacillus anthracis simulant by air sampling.

    PubMed

    Garza, Alexander G; Van Cuyk, Sheila M; Brown, Michael J; Omberg, Kristin M

    2014-01-01

    In 2005 and 2009, the Pentagon Force Protection Agency (PFPA) staged deliberate releases of a commercially available organic pesticide containing Bacillus amyloliquefaciens to evaluate PFPA's biothreat response protocols. In concert with, but independent of, these releases, the Department of Homeland Security sponsored experiments to evaluate the efficacy of commonly employed air and surface sampling techniques for detection of an aerosolized biological agent. High-volume air samplers were placed in the expected downwind plume, and samples were collected before, during, and after the releases. Environmental surface and personal air samples were collected in the vicinity of the high-volume air samplers hours after the plume had dispersed. The results indicate it is feasible to detect the release of a biological agent in an urban area both during and after the release of a biological agent using high-volume air and environmental sampling techniques.

  9. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF PERSONAL AIR SAMPLES FOR ANALYSIS OF PESTICIDES OR METALS (UA-F-14.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedure for sampling personal air for metals and pesticides during a predetermined time period. The SOP includes the set up of the samplers for collection of either a metals sample or a pesticides sample, the calibration and initial c...

  10. EVALUATION OF SOLID ADSORBENTS FOR THE COLLECTION AND ANALYSES OF AMBIENT BIOGENIC VOLATILE ORGANICS

    EPA Science Inventory

    Micrometeorological flux measurements of biogenic volatile organic compounds (BVOCs) usually require that large volumes of air be collected (whole air samples) or focused during the sampling process (cryogenic trapping or gas-solid partitioning on adsorbents) in order to achiev...

  11. Biological monitoring of welders' exposure to chromium, molybdenum, tungsten and vanadium.

    PubMed

    Ellingsen, Dag G; Chashchin, Maxim; Berlinger, Balazs; Fedorov, Vladimir; Chashchin, Valery; Thomassen, Yngvar

    2017-05-01

    Welders are exposed to a number of metallic elements during work. Bioaccessability, that is important for element uptake, has been little studied. This study addresses bioaccessability and uptake of chromium (Cr), molybdenum (Mo), tungsten (W) and vanadium (V) among welders. Bioaccessability of Cr, Mo, V and W was studied in airborne particulate matter collected by personal sampling of the workroom air among shipyard welders by using the lung lining fluid simulant Hatch solution. Associations between concentrations of Hatch soluble and non-soluble elements (Hatch sol and Hatch non-sol ) and concentrations of the four elements in whole blood, serum, blood cells and urine were studied. Air concentrations of the four elements were low. Only a small fraction of Cr, V and W was Hatch sol , while similar amounts of Mo were Hatch sol and Hatch non-sol . Welders (N=70) had statistically significantly higher concentrations of all four elements in urine and serum when compared to referents (N=74). Highly statistically significant associations were observed between urinary W and Hatch sol W (p<0.001) and serum V and Hatch sol V (p<0.001), in particular when air samples collected the day before collection of biological samples were considered. Associations between Hatch sol elements in air and their biological concentrations were higher than when Hatch non-sol concentrations were considered. Associations were generally higher when air samples collected the day before biological sampling were considered as compared to air samples collected two days before. Copyright © 2017 Elsevier GmbH. All rights reserved.

  12. Colloidal-facilitated transport of inorganic contaminants in ground water: part 1, sampling considerations

    USGS Publications Warehouse

    Puls, Robert W.; Eychaner, James H.; Powell, Robert M.

    1996-01-01

    Investigations at Pinal Creek, Arizona, evaluated routine sampling procedures for determination of aqueous inorganic geochemistry and assessment of contaminant transport by colloidal mobility. Sampling variables included pump type and flow rate, collection under air or nitrogen, and filter pore diameter. During well purging and sample collection, suspended particle size and number as well as dissolved oxygen, temperature, specific conductance, pH, and redox potential were monitored. Laboratory analyses of both unfiltered samples and the filtrates were performed by inductively coupled argon plasma, atomic absorption with graphite furnace, and ion chromatography. Scanning electron microscopy with Energy Dispersive X-ray was also used for analysis of filter particulates. Suspended particle counts consistently required approximately twice as long as the other field-monitored indicators to stabilize. High-flow-rate pumps entrained normally nonmobile particles. Difference in elemental concentrations using different filter-pore sizes were generally not large with only two wells having differences greater than 10 percent in most wells. Similar differences (>10%) were observed for some wells when samples were collected under nitrogen rather than in air. Fe2+/Fe3+ ratios for air-collected samples were smaller than for samples collected under a nitrogen atmosphere, reflecting sampling-induced oxidation.

  13. Double-layer Tedlar bags: a means to limit humidity evolution of air samples and to dry humid air samples.

    PubMed

    Cariou, Stephane; Guillot, Jean-Michel

    2006-01-01

    Tedlar bags, which are widely used to collect air samples, especially VOCs and odorous atmospheres, can allow humidity to diffuse when relative humidity levels differ between the inside and outside. Starting with dry air inside the bag and humid air outside, we monitored equilibrium times under several conditions showing the evolution and influence of collected volumes and exposed surfaces. A double-film Tedlar bag was made, to limit the impact of external humidity on a sample at low humidity level. With the addition of a drying agent between both films, the evolution of humidity of a sample can be stopped for several hours. When a VOC mixture was monitored in a humid atmosphere, humidity was decreased but no significant evolution of VOC concentrations was observed.

  14. Composition and Trends of Short-Lived Trace Gases in the UT/LS over Europe Observed by the CARIBIC Aircraft

    NASA Astrophysics Data System (ADS)

    Baker, A. K.; Brenninkmeijer, C. A.; Oram, D. E.; O'Sullivan, D. A.; Slemr, F.; Schuck, T. J.

    2009-12-01

    The CARIBIC project (Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container) involves the monthly deployment of an instrument container equipped to make atmospheric measurements from aboard a commercial airliner, and has operated since 2005 from aboard a Lufthansa Airbus 340-600 . Measurements from the container include in-situ trace gas and aerosol analyses and the collection of aerosol and whole air samples for post-flight laboratory analysis. Measurements made from the sampling flasks include greenhouse gas (GHG), halocarbon and nonmethane hydrocarbon (NMHC) analysis. CARIBIC flights originate in Frankfurt, Germany with routes to India, East Asia, South America, North America and Africa, and typical aircraft cruising altitudes of 10-12km allow for the monitoring of the upper troposphere/lower stratosphere (UT/LS) along these routes. Data collected during the aircraft’s departure from and return to Frankfurt provide a 4 year time series of near-monthly measurements of the composition of the UT/LS above Europe. Here we present a discussion of the composition of short-lived trace gases in the whole air samples collected above Europe during CARIBIC flights. Over 150 air samples were collected between May 2005 and July 2009, or about 4 samples per month. Of the whole air samples collected, about 45% showed influence by stratospheric air (i.e. very low values of GHG, NMHC and halocarbons, elevated O3, high potential vorticity). The remaining samples were representative of the upper troposphere; back trajectories for these samples indicate that a little over half were collected in air masses that had been in the boundary layer within the previous 8 days. The predominant source regions for these samples were the Gulf of Mexico and continental North America. Owing to their wide range of chemical lifetimes and the varying composition of emissions, short-lived trace gases transported to the UT/LS can be useful indicators of source region, photochemical processing and transport timescales of an air mass. Seasonal and longer-term trends in trace gases and trace gas composition are discussed, as well as composition of air masses having different origins. Additionally, we apply relationships between the different species, particularly the NMHC, to gain a qualitative understanding of photochemical processes occurring during transport from the boundary layer to the upper troposphere over Europe.

  15. Water- and air-quality monitoring of the Sweetwater Reservoir Watershed, San Diego County, California - Phase One results, continued, 2001-2003

    USGS Publications Warehouse

    Mendez, Gregory O.; Foreman, William T.; Morita, Andrew; Majewski, Michael S.

    2008-01-01

    In 1998, the U.S. Geological Survey, in cooperation with the Sweetwater Authority, began a study to monitor water, air, and sediment at the Sweetwater and Loveland Reservoirs in San Diego County, California. The study includes regular sampling of water and air at Sweetwater Reservoir for chemical constituents, including volatile organic compounds (VOC), polynuclear aromatic hydrocarbons (PAH), pesticides, and major and trace elements. The purpose of this study is to monitor changes in contaminant composition and concentration during the construction and operation of State Route 125. To accomplish this, the study was divided into two phases. Phase One sampling (water years 1998–2004) determined baseline conditions for the detection frequency and the concentrations of target compounds in air and water. Phase Two sampling (starting water year 2005) continues at selected monitoring sites during and after construction of State Route 125 to assess the chemical impact this roadway alignment may have on water quality in the reservoir. Water samples were collected for VOCs and pesticides at Loveland Reservoir during Phase One and will be collected during Phase Two for comparison purposes. Air samples collected to monitor changes in VOCs, PAHs, and pesticides were analyzed by adapting methods used to analyze water samples. Bed-sediment samples have been and will be collected three times during the study; at the beginning of Phase One, at the start of Phase Two, and near the end of the study. In addition to the ongoing data collection, several special studies were initiated to assess the occurrence of specific chemicals of concern, such as trace metals, anthropogenic indicator compounds, and pharmaceuticals. This report describes the study design, and the sampling and analytical methods, and presents data from water and air samples collected during the fourth and fifth years of Phase One of the study (October 2001 to September 2003). Data collected during the first three years has been previously published. Three types of quality-control samples were used in this study: blanks, spikes, and replicates. Blanks and spikes are used to estimate result bias, and replicates are used to estimate result variability. Additionally, surrogate compounds were added at the laboratory to samples of VOCs, PAHs, pesticides, anthropogenic indicator compounds, and pharmaceuticals to monitor sample-specific performance of the analytical method.

  16. Direct impact aerosol sampling by electrostatic precipitation

    DOEpatents

    Braden, Jason D.; Harter, Andrew G.; Stinson, Brad J.; Sullivan, Nicholas M.

    2016-02-02

    The present disclosure provides apparatuses for collecting aerosol samples by ionizing an air sample at different degrees. An air flow is generated through a cavity in which at least one corona wire is disposed and electrically charged to form a corona therearound. At least one grounded sample collection plate is provided downstream of the at least one corona wire so that aerosol ions generated within the corona are deposited on the at least one grounded sample collection plate. A plurality of aerosol samples ionized to different degrees can be generated. The at least one corona wire may be perpendicular to the direction of the flow, or may be parallel to the direction of the flow. The apparatus can include a serial connection of a plurality of stages such that each stage is capable of generating at least one aerosol sample, and the air flow passes through the plurality of stages serially.

  17. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR PREPARATION OF FILTERS AND PUF FOR FIELD COLLECTION OF METALS AND PESTICIDES IN AIR (BCO-L-2.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for pre-cleaning filters and polyurethane foam (PUF) plug prior to air sampling with these media. The sampling media are used for sampling indoor air, outdoor air, and personal air. This procedure was followed to ensure consi...

  18. Atmospheric Concentrations of Persistent Organic Pollutants in the Southern Ocean

    NASA Astrophysics Data System (ADS)

    Vlahos, P.; Edson, J.; Cifuentes, A.; McGillis, W. R.; Zappa, C.

    2008-12-01

    Long-range transport of persistent organic pollutant (POPs) is a global concern. Remote regions such as the Southern Ocean are greatly under-sampled though critical components in understanding POPs cycling. Over 20 high-volume air samples were collected in the Southern Ocean aboard the RV Brown during the GASEX III experiment between Mar 05 to April 9 2008. The relatively stationary platform (51S,38W) enabled the collection of a unique atmospheric time series at this open ocean station. Air sampling was also conducted across transects from Punto Arenas, Chile and to Montevideo, Uruguay. Samples were collected using glass sleeves packed with poly-urethane foam plugs and C-18 resin in order to collect target organic pollutants (per-fluorinated compounds, currently and historically used pesticides) in this under-sampled region. Here we present POPs concentrations and trends over the sampled period and compare variations with air parcel back trajectories to establish potential origins of their long-range transport.

  19. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    PubMed

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  20. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    PubMed Central

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-01-01

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202

  1. VOCS IN AMBIENT AIR NEAR WORLD TRADE CENTER SITE

    EPA Science Inventory

    Beginning on September 22, 2001 and continuing through February 2002, ambient air samples were collected at three sites within a block of ground zero and at a fourth site on the 16th floor of a building at 290 Broadway. Grab samples were collected in evacuated, electro-polished...

  2. ORGANOCHLORINE PESTICIDE CONCENTRATIONS AND ENANTIOMER FRACTIONS FOR CHLORDANE IN INDOOR AIR FROM THE U.S. CORNBELT

    EPA Science Inventory

    Thirty-seven indoor air samples were collected and analyzed to determine if enantioselective degradation of past use organochlorine pesticides occurs indoors and to increase the available information on concentrations in homes. Samples were collected from homes in the U.S. cor...

  3. Comparison of passive diffusion bag samplers and submersible pump sampling methods for monitoring volatile organic compounds in ground water at Area 6, Naval Air Station, Whidbey Island, Washington

    USGS Publications Warehouse

    Huffman, Raegan L.

    2002-01-01

    Ground-water samples were collected in April 1999 at Naval Air Station Whidbey Island, Washington, with passive diffusion samplers and a submersible pump to compare concentrations of volatile organic compounds (VOCs) in water samples collected using the two sampling methods. Single diffusion samplers were installed in wells with 10-foot screened intervals, and multiple diffusion samplers were installed in wells with 20- to 40-foot screened intervals. The diffusion samplers were recovered after 20 days and the wells were then sampled using a submersible pump. VOC concentrations in the 10-foot screened wells in water samples collected with diffusion samplers closely matched concentrations in samples collected with the submersible pump. Analysis of VOC concentrations in samples collected from the 20- to 40-foot screened wells with multiple diffusion samplers indicated vertical concentration variation within the screened interval, whereas the analysis of VOC concentrations in samples collected with the submersible pump indicated mixing during pumping. The results obtained using the two sampling methods indicate that the samples collected with the diffusion samplers were comparable with and can be considerably less expensive than samples collected using a submersible pump.

  4. Effect of temperature on the breakthrough of a charcoal tube during vinyl chloride monomer sampling.

    PubMed

    Roh, J; Park, Y J; Kim, C N; Lim, N G; Lee, S H; Song, J S; Won, J U; Talaska, G

    2000-01-01

    This study evaluated the effects of temperature on breakthrough of two standard collection media at various concentrations during vinyl chloride monomer (VCM) sampling. The National Institute for Occupational Safety and Health (NIOSH) and Occupational Safety and Health Administration (OSHA) methods were evaluated. To determine whether breakthrough of VCM would occur at the extremes of exposure and temperature that might be encountered in some workplaces, air samples containing 4 ppm (10.24 mg/m3), 8 ppm (20.45 mg/m3), 16 ppm (40.98 mg/m3), and 32 ppm (81.80 mg/m3) of VCM were collected at temperatures of 4, 22, and 40 degrees C. Five liters of air was sampled at the rate of 0.05 L/min for 100 min using the activated charcoal tube recommended by NIOSH. A second tube was added to the sampling train to collect any VCM that might not have been absorbed in the first tube. To collect VCM air samples by the OSHA method, two carbon molecular sieve tubes were connected serially and 3 L of air was sampled at the rate of 0.05 L/min for 60 min. A gas chromatograph with a flame ionization detector and ultra 2 capillary column was used to analyze VCM. Significant breakthrough was found when sampling at higher temperatures with the NIOSH method. No breakthrough was found when samples were collected using the OSHA media at different temperatures and concentrations. Therefore, under hot ambient conditions (>22 degrees C), the possibility of breakthrough should be considered when sampling VCM by the NIOSH method.

  5. Spectral fingerprinting of polycyclic aromatic hydrocarbons in high-volume ambient air samples by constant energy synchronous luminescence spectroscopy

    USGS Publications Warehouse

    Kerkhoff, M.J.; Lee, T.M.; Allen, E.R.; Lundgren, D.A.; Winefordner, J.D.

    1985-01-01

    A high-volume sampler fitted with a glass-fiber filter and backed by polyurethane foam (PUF) was employed to collect airborne particulate and gas-phase polycylic aromatic hydrocarbons (PAHs) in ambient air. Samples were collected from four sources representing a range of environmental conditions: gasoline engine exhaust, diesel engine exhaust, air near a heavily traveled interstate site, and air from a moderately polluted urban site. Spectral fingerprints of the unseparated particulate and gas-phase samples were obtained by constant energy synchronous luminescence spectroscopy (CESLS). Five major PAHs in the gas-phase extracts were characterized and estimated. The compatibility of a high-volume sampling method using polyurethane foam coupled with CESLS detection is explored for use as a screening technique for PAHs in ambient air. ?? 1985 American Chemical Society.

  6. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR USE OF AN ACTIVE SAMPLING DEVICE FOR THE COLLECTION OF AIRBORNE VOCS AT FIXED INDOOR AND OUTDOOR SITES (UA-F-11.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used to collect indoor and outdoor air samples for the determination of selected volatile organic compounds (VOC's) using a pump to draw air through a Carbotrap Sampler. Volatile organic compounds (VOCs) present in the air are p...

  7. 43 CFR 3430.4-4 - Environmental costs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and analyzing baseline data on surface water quality and quantity (collecting and analyzing samples...). (2) Groundwater—costs of collecting and analyzing baseline data on groundwater quality and quantity... analyzing baseline air quality data (purchasing rain, air direction, and wind guages and air samplers and...

  8. 43 CFR 3430.4-4 - Environmental costs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and analyzing baseline data on surface water quality and quantity (collecting and analyzing samples...). (2) Groundwater—costs of collecting and analyzing baseline data on groundwater quality and quantity... analyzing baseline air quality data (purchasing rain, air direction, and wind guages and air samplers and...

  9. 43 CFR 3430.4-4 - Environmental costs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... and analyzing baseline data on surface water quality and quantity (collecting and analyzing samples...). (2) Groundwater—costs of collecting and analyzing baseline data on groundwater quality and quantity... analyzing baseline air quality data (purchasing rain, air direction, and wind guages and air samplers and...

  10. 43 CFR 3430.4-4 - Environmental costs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... and analyzing baseline data on surface water quality and quantity (collecting and analyzing samples...). (2) Groundwater—costs of collecting and analyzing baseline data on groundwater quality and quantity... analyzing baseline air quality data (purchasing rain, air direction, and wind guages and air samplers and...

  11. ATMOSPHERIC VOLATILE ORGANIC COMPOUND MEASUREMENTS DURING THE 1996 PASO DEL NORTE OZONE STUDY

    EPA Science Inventory

    Ambient air VOC samples were collected at surface air quality monitoring sites, near sources of interest, and aloft on the US (El Paso) and Mexican (Ciudad Juarez) side of the border during a six-week period of the 1996 Paso del Norte Ozone Study. Samples were collected at five...

  12. Polychlorinated biphenyls (PCBs) and hexachlorobenzene (HCB) in the equatorial Indian Ocean: temporal trend, continental outflow and air-water exchange.

    PubMed

    Huang, Yumei; Li, Jun; Xu, Yue; Xu, Weihai; Cheng, Zhineng; Liu, Junwen; Wang, Yan; Tian, Chongguo; Luo, Chunling; Zhang, Gan

    2014-03-15

    Nineteen pairs of air and seawater samples collected from the equatorial Indian Ocean onboard the Shiyan I from 4/2011 to 5/2011 were analyzed for PCBs and HCB. Gaseous concentrations of ∑(ICES)PCBs (ICES: International Council for the Exploration of the Seas) and HCB were lower than previous data over the study area. Air samples collected near the coast had higher levels of PCBs relative to those collected in the open ocean, which may be influenced by proximity to source regions and air mass origins. Dissolved concentrations of ∑(ICES)PCBs and HCB were 1.4-14 pg L⁻¹ and 0.94-13 pg L⁻¹, with the highest concentrations in the sample collected from Strait of Malacca. Fugacity fractions suggest volatilization of PCBs and HCB from the seawater to air during the cruise, with fluxes of 0.45-34 ng m⁻² d⁻¹ and 0.36-18 ng m⁻² d⁻¹, respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Optimization of sampling parameters for collection and preconcentration of alveolar air by needle traps.

    PubMed

    Filipiak, Wojciech; Filipiak, Anna; Ager, Clemens; Wiesenhofer, Helmut; Amann, Anton

    2012-06-01

    The approach for breath-VOCs' collection and preconcentration by applying needle traps was developed and optimized. The alveolar air was collected from only a few exhalations under visual control of expired CO(2) into a large gas-tight glass syringe and then warmed up to 45 °C for a short time to avoid condensation. Subsequently, a specially constructed sampling device equipped with Bronkhorst® electronic flow controllers was used for automated adsorption. This sampling device allows time-saving collection of expired/inspired air in parallel onto three different needle traps as well as improvement of sensitivity and reproducibility of NT-GC-MS analysis by collection of relatively large (up to 150 ml) volume of exhaled breath. It was shown that the collection of alveolar air derived from only a few exhalations into a large syringe followed by automated adsorption on needle traps yields better results than manual sorption by up/down cycles with a 1 ml syringe, mostly due to avoided condensation and electronically controlled stable sample flow rate. The optimal profile and composition of needle traps consists of 2 cm Carbopack X and 1 cm Carboxen 1000, allowing highly efficient VOCs' enrichment, while injection by a fast expansive flow technique requires no modifications in instrumentation and fully automated GC-MS analysis can be performed with a commercially available autosampler. This optimized analytical procedure considerably facilitates the collection and enrichment of alveolar air, and is therefore suitable for application at the bedside of critically ill patients in an intensive care unit. Due to its simplicity it can replace the time-consuming sampling of sufficient breath volume by numerous up/down cycles with a 1 ml syringe.

  14. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FIXED SITE INDOOR AND OUTDOOR AIR SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.12)

    EPA Science Inventory

    This SOP describes the procedures to set up, calibrate, initiate and terminate air sampling for persistent organic pollutants. This method is used to sample air, indoors and outdoors, at homes and at day care centers over a 48-hr period.

  15. Measuring Concentrations of Particulate 140La in the Air

    DOE PAGES

    Okada, Colin E.; Kernan, Warnick J.; Keillor, Martin E.; ...

    2016-05-01

    Air sampling systems were deployed to measure the concentration of radioactive material in the air during the Full-Scale Radiological Dispersal Device experiments. The air samplers were positioned 100-600 meters downwind of the release point. The filters were collected immediately and analyzed in the field. Quantities for total activity collected on the air filters are reported along with additional information to compute the average or integrated air concentrations.

  16. A metagenomic framework for the study of airborne microbial communities.

    PubMed

    Yooseph, Shibu; Andrews-Pfannkoch, Cynthia; Tenney, Aaron; McQuaid, Jeff; Williamson, Shannon; Thiagarajan, Mathangi; Brami, Daniel; Zeigler-Allen, Lisa; Hoffman, Jeff; Goll, Johannes B; Fadrosh, Douglas; Glass, John; Adams, Mark D; Friedman, Robert; Venter, J Craig

    2013-01-01

    Understanding the microbial content of the air has important scientific, health, and economic implications. While studies have primarily characterized the taxonomic content of air samples by sequencing the 16S or 18S ribosomal RNA gene, direct analysis of the genomic content of airborne microorganisms has not been possible due to the extremely low density of biological material in airborne environments. We developed sampling and amplification methods to enable adequate DNA recovery to allow metagenomic profiling of air samples collected from indoor and outdoor environments. Air samples were collected from a large urban building, a medical center, a house, and a pier. Analyses of metagenomic data generated from these samples reveal airborne communities with a high degree of diversity and different genera abundance profiles. The identities of many of the taxonomic groups and protein families also allows for the identification of the likely sources of the sampled airborne bacteria.

  17. A Metagenomic Framework for the Study of Airborne Microbial Communities

    PubMed Central

    Tenney, Aaron; McQuaid, Jeff; Williamson, Shannon; Thiagarajan, Mathangi; Brami, Daniel; Zeigler-Allen, Lisa; Hoffman, Jeff; Goll, Johannes B.; Fadrosh, Douglas; Glass, John; Adams, Mark D.; Friedman, Robert; Venter, J. Craig

    2013-01-01

    Understanding the microbial content of the air has important scientific, health, and economic implications. While studies have primarily characterized the taxonomic content of air samples by sequencing the 16S or 18S ribosomal RNA gene, direct analysis of the genomic content of airborne microorganisms has not been possible due to the extremely low density of biological material in airborne environments. We developed sampling and amplification methods to enable adequate DNA recovery to allow metagenomic profiling of air samples collected from indoor and outdoor environments. Air samples were collected from a large urban building, a medical center, a house, and a pier. Analyses of metagenomic data generated from these samples reveal airborne communities with a high degree of diversity and different genera abundance profiles. The identities of many of the taxonomic groups and protein families also allows for the identification of the likely sources of the sampled airborne bacteria. PMID:24349140

  18. Use of dust fall filters as passive samplers for metal concentrations in air for communities near contaminated mine tailings

    PubMed Central

    Beamer, P.I.; Sugeng, A. J.; Kelly, M.D.; Lothrop, N.; Klimecki, W.; Wilkinson, S.T.; Loh, M.

    2014-01-01

    Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p<0.05), whose primary source in indoor air is resuspended soil from outdoors. In the second rural community, our estimated metal concentrations in air were comparable to active air sampling measurements taken previously. This passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites. PMID:24469149

  19. Occurrence and Spatial and Temporal Variations of Disinfection By-Products in the Water and Air of Two Indoor Swimming Pools

    PubMed Central

    Catto, Cyril; Sabrina, Simard; Ginette, Charest-Tardif; Manuel, Rodriguez; Robert, Tardif

    2012-01-01

    In order to improve disinfection by-product (DBP) exposure assessment, this study was designed to document both water and air levels of these chemical contaminants in two indoor swimming pools and to analyze their within-day and day-to-day variations in both of them. Intensive sampling was carried out during two one-week campaigns to measure trihalomethanes (THMs) and chloramines (CAMs) in water and air, and haloacetic acids (HAAs) in water several times daily. Water samples were systematically collected at three locations in each pool and air samples were collected at various heights around the pool and in other rooms (e.g., changing room) in the buildings. In addition, the ability of various models to predict air concentrations from water was tested using this database. No clear trends, but actual variations of contamination levels, appeared for both water and air according to the sampling locations and times. Likewise, the available models resulted in realistic but imprecise estimates of air contamination levels from water. This study supports the recommendation that suitable minimal air and water sampling should be carried out in swimming pools to assess exposure to DBPs. PMID:23066383

  20. [Gohieria fusca found in dust of air-conditioner filters].

    PubMed

    Qiang, Chai; Xiao-Dong, Zhan; Wei, Guo; Chao-Pin, Li

    2017-09-25

    To investigate the pollution status of Gohieria fusca in the air conditioner-filters of different places in Wuhu City. The dust samples were collected from the filters of air-conditioners in dining rooms, shopping malls, hotels and households between June and September, 2013, and G. fusca was detected in the dust samples. There were 430 dust samples collected and 98 were G. fusca positive with the breeding rate of 22.79%. The difference of breeding rates of G. fusca were statistically significant among the different places ( χ 2 =18.294, P < 0.05). Among 510.5 g dust samples in total, 783 G. fusca mites were detected with an average breeding density of 1.53 mite/g. G. fusca breeds in the dust of air-conditioner filters in Wuhu City gravely.

  1. Comparison of indoor air sampling and dust collection methods for fungal exposure assessment using quantitative PCR

    EPA Science Inventory

    Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample ...

  2. Air-conditioning vs. presence of pathogenic fungi in hospital operating theatre environment.

    PubMed

    Gniadek, Agnieszka; Macura, Anna B

    2011-01-01

    Infections related to modern surgical procedures present a difficult problem for contemporary medicine. Infections acquired during surgery represent a risk factor related to therapeutical interventions. Eradication of microorganisms from hospital operating theatre environment may contribute to reduction of infections as the laminar flow air-conditioning considerably reduces the number of microorganisms in the hospital environment. The objective of the study was to evaluate the occurrence of fungi in air-conditioned operating theatre rooms. The study was carried out in one of the hospitals in Krak6w during December 2009. Indoor air samples and imprints from the walls were collected from five operating theatre rooms. A total of fifty indoor air samples were collected with a MAS-100 device, and twenty five imprints from the walls were collected using a Count Tact method. Fungal growth was observed in 48 air samples; the average numbers of fungi were within the range of 5-100 c.f.u. in one cubic metre of the air. Fungi were detected only in four samples of the wall imprints; the number of fungi was 0.01 c.f.u. per one square centimetre of the surface. The mould genus Aspergillus was most frequently isolated, and the species A. fumigatus and A. versicolor were the dominating ones. To ensure microbiological cleanness of hospital operating theatre, the air-conditioning system should be properly maintained. Domination of the Aspergillus fungi in indoor air as well as increase in the number of moulds in the samples taken in evenings (p < 0.05) may suggest that the room decontamination procedures were neglected.

  3. Comparison of modern pollen distribution between the northern and southern parts of the South China Sea.

    PubMed

    Luo, Chuanxiu; Chen, Muhong; Xiang, Rong; Liu, Jianguo; Zhang, Lanlan; Lu, Jun

    2015-04-01

    The authors conducted a palynological analysis based on different number of air pollen samples for the northern and southern parts of the South China Sea, respectively, in order to give a reference to reconstruct the paleoclimate of the area. (1) Fifteen air pollen samples were collected from the northern part of the South China Sea from August to September 2011, and 13 air pollen samples were collected from the southern part of the South China Sea in December 2011. The pollen types were more abundant in the north than in the south. The total pollen number and concentration in the north was 10 times more than that in the south, which may be because of the sampling season. Airborne pollen types and concentrations have a close relationship with wind direction and distance from the sampling point to the continent. (2) Seventy-four samples were collected from surface sediments in the northern part of the South China Sea in the autumn. Thirty-three samples were collected from surface sediments in the southern part of the South China Sea in the winter. Pollen concentrations in the north were nearly 10 times higher than that in the south. This is because trilete spores are transported by rivers from Hainan Island to the sea and also by the summer monsoon-forced marine current. (3) Ten air pollen samples and 10 surface sediments samples were selected for comparison. The pollen and spores in the air were mainly herbaceous and woody pollen, excluding fern spores, having seasonal pollen characteristics. Pollen in the surface sediments were mainly trilete, Pinus, and herbaceous, and may also show a combination of annual pollen characteristics.

  4. iss038e053780

    NASA Image and Video Library

    2014-02-18

    ISS038-E-053780 (18 Feb. 2014) --- NASA astronaut Rick Mastracchio, Expedition 38 flight engineer, uses a Microbial Air Sampler to collect air samples in the Unity node of the International Space Station. These air samples will be incubated for five days and tested for signs of microbial contamination.

  5. EPA Air Method, Toxic Organics - 15 (TO-15): Determination of Volatile Organic Compounds (VOCs) in Air Collected in Specially-Prepared Canisters and Analyzed by Gas Chromatography/Mass Spectrometry (GC/MS)

    EPA Pesticide Factsheets

    Method T)-15 describes procedures for for preparation and analysis of air samples containing volatile organic compounds collected in specially-prepared canisters, using gas chromatography-mass spectrometry.

  6. Determination of formaldehyde by HPLC as the DNPH derivative following high-volume air sampling onto bisulfite-coated cellulose filters

    NASA Astrophysics Data System (ADS)

    de Andrade, Jailson B.; Tanner, Roger L.

    A method is described for the specific collection of formaldehyde as hydroxymethanesulfonate on bisulfate-coated cellulose filters. Following extraction in aqueous acid and removal on unreacted bisulfite, the hydroxymethanesulfonate is decomposed by base, and HCHO is determined by DNPH (2,4-dinitrophenylhydrazine) derivatization and HPLC. Since the collection efficiency for formaldehyde is moderately high even when sampling ambient air at high-volume flow rates, a limit of detection of 0.2 ppbv is achieved with 30 min sampling times. Interference from acetaldehyde co-collected as 1-hydroxyethanesulfonate is <5% using this procedure. The technique shows promise for both short-term airborne sampling, and as a means of collecting mg-sized samples of HCHO on an inorganic matrix for carbon isotopic analyses.

  7. A novel enhanced diffusion sampler for collecting gaseous pollutants without air agitation.

    PubMed

    Pan, Xuelian; Zhuo, Shaojie; Zhong, Qirui; Chen, Yuanchen; Du, Wei; Cheng, Hefa; Wang, Xilong; Zeng, Eddy Y; Xing, Baoshan; Tao, Shu

    2018-03-06

    A novel enhanced diffusion sampler for collecting gaseous phase polycyclic aromatic hydrocarbons (PAHs) without air agitation is proposed. The diffusion of target compounds into a sampling chamber is facilitated by continuously purging through a closed-loop flow to create a large concentration difference between the ambient air and the air in the sampling chamber. A glass-fiber filter-based prototype was developed. It was demonstrated that the device could collect gaseous PAHs at a much higher rate (1.6 ± 1.4 L/min) than regular passive samplers, while the ambient air is not agitated. The prototype was also tested in both the laboratory and field for characterizing the concentration gradients over a short distance from the soil surface. The sampler has potential to be applied in other similar situations to characterize the concentration profiles of other chemicals.

  8. Atmospheric Carbon Dioxide Mixing Ratios from the NOAA CMDL Carbon Cycle Cooperative Global Air Sampling Network (2009)

    DOE Data Explorer

    Conway, Thomas [NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, CO (USA); Tans, Pieter [NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, CO (USA)

    2009-01-01

    The National Oceanic and Atmospheric Administration's Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) has measured CO2 in air samples collected weekly at a global network of sites since the late 1960s. Atmospheric CO2 mixing ratios reported in these files were measured by a nondispersive infrared absorption technique in air samples collected in glass flasks. All CMDL flask samples are measured relative to standards traceable to the World Meteorological Organization (WMO) CO2 mole fraction scale. These measurements constitute the most geographically extensive, carefully calibrated, internally consistent atmospheric CO2 data set available and are essential for studies aimed at better understanding the global carbon cycle budget.

  9. Review of Various Air Sampling Methods for Solvent Vapors.

    ERIC Educational Resources Information Center

    Maykoski, R. T.

    Vapors of trichloroethylene, toluene, methyl ethyl ketone, and butyl cellosolve in air were collected using Scotchpac and Tedlar bags, glass prescription bottles, and charcoal adsorption tubes. Efficiencies of collection are reported. (Author/RH)

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monroy, G.J. Keene, F.E.

    A study to address Ambos (Both) Nogales' air quality concerns was conducted by the Arizona Department of Environmental Quality (ADEQ), in conjunction with Mexico's Secretaria de Medio Ambiente, Recursos Naturales y Pesca (SEMARNAP), from 1994 to 1998. The study, which is part of the US-Mexico Border XXI Program, consisted of the following tasks: (1) air sampling/monitoring; (2) emissions inventory; (3) meteorological modeling; and, (4) health risk assessment. The following types of samples were collected: particulate matter (PM); volatile organic compounds; semi-volatile organic compounds; and aldehydes. All samples were collected for a 24-hour period; every sixth day during the warm monthsmore » (April--September), and every third day during the cold months (October--March). There were a total of six sampling stations; three on each side of the border. PM samples were collected at all six sites, while samples for Hazardous Air Pollutants (HAPs) were collected at four of those sites. Sample analyses were performed at the Desert Research Institute (DRI) in Reno, Nevada. Furthermore, four of the sites were outfitted with meteorological equipment, in order to gather data on wind speed and direction. PM and meteorological data are still being collected at two sampling sites, one in Arizona and one in Sonora. An emissions inventory of point, mobile and area sources for the Ambos Nogales area (12 x 19 km. domain), was developed following completion of the sampling effort. In order to accomplish this task, ADEQ contracted the services of RADIAN International and Powers Engineering; which in turn enlisted the services of Heuristica Ambiental of Hermosillo, Sonora. This task was completed in July, 1997. Vehicular emissions were found to be one of the main contributors of air emissions in the Ambos Nogales area. The third task of this project consisted developing meteorological models of the study area.« less

  11. A survey on polycyclic aromatic hydrocarbon concentrations in soil in Chiang-Mai, Thailand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amagai, Takashi; Takahashi, Yukari; Matsushita, Hidetsuru

    Soil samples were collected at 30 sampling sites along roadsides in the city of Chiang-Mai, Thailand, in February 1996, and concentrations of 16 polycyclic aromatic hydrocarbons (PAHs) were determined. The distribution of PAH concentration in the soil samples was almost log-normal for all PAHs. Concentrations of pyrene (Py) and fluoranthene (Fluor) were the highest, followed by those of benzo[ghi]perylene and coronene (Cor). Since PAH concentrations were highest on the roadside where the traffic density was high, vehicles were the main determinants of PAH concentration in soil in Chiang-Mai. Significant correlations among PAH concentrations were found for almost all PAHs. PAHmore » profiles in the air were different from those in the soil. For example, relative benzo[a]pyrene (BaP) concentration in the soil was significantly lower than that in the air. Relative concentrations of Fluor, Py, chrysene, and Cor in the soil were considerably higher than those in the air, due presumably to their difference in photochemical reactivities and in sources. The sampling of soil has advantages relative to that of air: (1) collection of soil is easy; (2) it needs no special equipment and electricity; (3) it takes little time; and (4) it can be collected anywhere. Therefore PAH analysis in soil was useful as a proxy-screening tool for air pollution levels with consideration of compositional differences between soil and air samples.« less

  12. Urban Air Toxics Monitoring Program, 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McAllister, R.A.; Moore, W.H.; Rice, J.

    1990-10-01

    From January 1989 through January 1990 samples of ambient air were collected at 14 sites in the eastern part of the U.S. Every 12 days, air was integrated over 24-hour periods into passivated stainless steel canisters. Simultaneously, air was drawn through cartridges containing dinitrophenylhydrazine to collect carbonyl compounds. The samples were analyzed at a central laboratory for a total of 37 halogenated and aromatic hydrocarbons, formaldehyde, acetaldehyde, and other oxygenated species. The hydrocarbon species were analyzed by gas chromatography/multiple detectors and gas chromatography/mass spectrometry, while the carbonyl species were analyzed by liquid chromatography. An extensive quality assurance program was carriedmore » on to secure high quality data. Complete data for all the carbonyl samples are presented in the report.« less

  13. [Evaluation of uncertainty for determination of tin and its compounds in air of workplace by flame atomic absorption spectrometry].

    PubMed

    Wei, Qiuning; Wei, Yuan; Liu, Fangfang; Ding, Yalei

    2015-10-01

    To investigate the method for uncertainty evaluation of determination of tin and its compounds in the air of workplace by flame atomic absorption spectrometry. The national occupational health standards, GBZ/T160.28-2004 and JJF1059-1999, were used to build a mathematical model of determination of tin and its compounds in the air of workplace and to calculate the components of uncertainty. In determination of tin and its compounds in the air of workplace using flame atomic absorption spectrometry, the uncertainty for the concentration of the standard solution, atomic absorption spectrophotometer, sample digestion, parallel determination, least square fitting of the calibration curve, and sample collection was 0.436%, 0.13%, 1.07%, 1.65%, 3.05%, and 2.89%, respectively. The combined uncertainty was 9.3%.The concentration of tin in the test sample was 0.132 mg/m³, and the expanded uncertainty for the measurement was 0.012 mg/m³ (K=2). The dominant uncertainty for determination of tin and its compounds in the air of workplace comes from least squares fitting of the calibration curve and sample collection. Quality control should be improved in the process of calibration curve fitting and sample collection.

  14. Profiling quinones in ambient air samples collected from the Athabasca region (Canada).

    PubMed

    Wnorowski, Andrzej; Charland, Jean-Pierre

    2017-12-01

    This paper presents new findings on polycyclic aromatic hydrocarbon oxidation products-quinones that were collected in ambient air samples in the proximity of oil sands exploration. Quinones were characterized for their diurnal concentration variability, phase partitioning, and molecular size distribution. Gas-phase (GP) and particle-phase (PM) ambient air samples were collected separately in the summer; a lower quinone content was observed in the PM samples from continuous 24-h sampling than from combined 12-h sampling (day and night). The daytime/nocturnal samples demonstrated that nighttime conditions led to lower concentrations and some quinones not being detected. The highest quinone levels were associated with wind directions originating from oil sands exploration sites. The statistical correlation with primary pollutants directly emitted from oil sands industrial activities indicated that the bulk of the detected quinones did not originate directly from primary emission sources and that quinone formation paralleled a reduction in primary source NO x levels. This suggests a secondary chemical transformation of primary pollutants as the origin of the determined quinones. Measurements of 19 quinones included five that have not previously been reported in ambient air or in Standard Reference Material 1649a/1649b and seven that have not been previously measured in ambient air in the underivatized form. This is the first paper to report on quinone characterization in secondary organic aerosols originating from oil sands activities, to distinguish chrysenequinone and anthraquinone positional isomers in ambient air, and to report the requirement of daylight conditions for benzo[a]pyrenequinone and naphthacenequinone to be present in ambient air. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  15. US EPA Base Study Standard Operating Procedure for Sampling and Characterization of Viable and Non-Viable Bioaerosols in Indoor Air

    EPA Pesticide Factsheets

    The objective of the procedure is to collect a representative sample concentration of total airborne fungal spores (viable and non-viable) that may be present in indoor air and in the outdoor air supplied to the space tested.

  16. Microbial assessment of cabin air quality on commercial airliners

    NASA Technical Reports Server (NTRS)

    La Duc, Myron T.; Stuecker, Tara; Bearman, Gregory; Venkateswaran, Kasthuri

    2005-01-01

    The microbial burdens of 69 cabin air samples collected from commercial airliners were assessed via conventional culture-dependent, and molecular-based microbial enumeration assays. Cabin air samples from each of four separate flights aboard two different carriers were collected via air-impingement. Microbial enumeration techniques targeting DNA, ATP, and endotoxin were employed to estimate total microbial burden. The total viable microbial population ranged from 0 to 3.6 x10 4 cells per 100 liters of air, as assessed by the ATP-assay. When these same samples were plated on R2A minimal medium, anywhere from 2% to 80% of these viable populations were cultivable. Five of the 29 samples examined exhibited higher cultivable counts than ATP derived viable counts, perhaps a consequence of the dormant nature (and thus lower concentration of intracellular ATP) of cells inhabiting these air cabin samples. Ribosomal RNA gene sequence analysis showed these samples to consist of a moderately diverse group of bacteria, including human pathogens. Enumeration of ribosomal genes via quantitative-PCR indicated that population densities ranged from 5 x 10 1 ' to IO 7 cells per 100 liters of air. Each of the aforementioned strategies for assessing overall microbial burden has its strengths and weaknesses; this publication serves as a testament to the power of their use in concert.

  17. An automated atmospheric sampling system operating on 747 airliners

    NASA Technical Reports Server (NTRS)

    Perkins, P. J.; Gustafsson, U. R. C.

    1976-01-01

    An air sampling system that automatically measures the temporal and spatial distribution of particulate and gaseous constituents of the atmosphere is collecting data on commercial air routes covering the world. Measurements are made in the upper troposphere and lower stratosphere (6 to 12 km) of constituents related to aircraft engine emissions and other pollutants. Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This unique system includes specialized instrumentation, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituent and related flight data are tape recorded in flight for later computer processing on the ground.

  18. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    PubMed

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration.

  19. Trace gas measurements from whole air samples collected over the Antarctic continent

    NASA Technical Reports Server (NTRS)

    Heidt, L. E.; Vedder, J. F.; Pollock, Walter H.; Henry, Bruce E.; Lueb, Richard A.

    1988-01-01

    Whole air samples collected aboard the NASA DC-8 and ER-2 aircraft as part of the Airborne Antarctic Ozone Experiment (AAOE) were analyzed in a field laboratory set up at Punta Arenas, Chile, in August and September, 1987. Mixing ratios obtained from gas chromatographic analyses of these samples are presented for N2O, CFCl3, CFCl2, C2F3Cl3, CH3CCl3, CH4, and CO. Variations in the mixing ratios of these gases along the individual flight paths of the aircraft are used as tracers to indicate the history of air masses over and near the Antarctic continent.

  20. Relationship of Indoor, Outdoor and Personal Air (RIOPA) study: study design, methods and quality assurance/control results.

    PubMed

    Weisel, Clifford P; Zhang, Junfeng; Turpin, Barbara J; Morandi, Maria T; Colome, Steven; Stock, Thomas H; Spektor, Dalia M; Korn, Leo; Winer, Arthur; Alimokhtari, Shahnaz; Kwon, Jaymin; Mohan, Krishnan; Harrington, Robert; Giovanetti, Robert; Cui, William; Afshar, Masoud; Maberti, Silvia; Shendell, Derek

    2005-03-01

    The Relationship of Indoor, Outdoor and Personal Air (RIOPA) Study was undertaken to evaluate the contribution of outdoor sources of air toxics, as defined in the 1990 Clean Air Act Amendments, to indoor concentrations and personal exposures. The concentrations of 18 volatile organic compounds (VOCs), 17 carbonyl compounds, and fine particulate matter mass (PM(2.5)) were measured using 48-h outdoor, indoor and personal air samples collected simultaneously. PM2.5 mass, as well as several component species (elemental carbon, organic carbon, polyaromatic hydrocarbons and elemental analysis) were also measured; only PM(2.5) mass is reported here. Questionnaires were administered to characterize homes, neighborhoods and personal activities that might affect exposures. The air exchange rate was also measured in each home. Homes in close proximity (<0.5 km) to sources of air toxics were preferentially (2:1) selected for sampling. Approximately 100 non-smoking households in each of Elizabeth, NJ, Houston, TX, and Los Angeles, CA were sampled (100, 105, and 105 respectively) with second visits performed at 84, 93, and 81 homes in each city, respectively. VOC samples were collected at all homes, carbonyls at 90% and PM(2.5) at 60% of the homes. Personal samples were collected from nonsmoking adults and a portion of children living in the target homes. This manuscript provides the RIOPA study design and quality control and assurance data. The results from the RIOPA study can potentially provide information on the influence of ambient sources on indoor air concentrations and exposure for many air toxics and will furnish an opportunity to evaluate exposure models for these compounds.

  1. High Volume Air Sampling for Viral Aerosols: A Comparative Approach

    DTIC Science & Technology

    2010-03-01

    Solid Impaction Aerosol Collection (Verreault, 2008. Reproduced with Permission from American Society of Microbiology ) Liquid collection...Reproduced with Permission from American Society of Microbiology ) Filter aerosol collection is often more efficient than other sampling...collected using a crude filter consisting of a glass tube packed with dry cotton. Sample analysis was conducted by inoculating chicken embryos with

  2. PAH and PCB in the Baltic -- A budget approach including fluxes, occurrence and concentration variability in air, suspended and settling particulates in water, surface sediments and river water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Broman, D.; Axelman, J.; Bandh, C.

    In order to study the fate and occurrence of two groups of hydrophobic compounds in the Baltic aquatic environment a large number of samples were collected from the southern Baltic proper to the northern Bothnian Bay for the analyses of polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs). The following sample matrices were collected; bottom surface sediments (0--1 cm, collected with gravity corer), settling particulate matter (collected with sediment traps), open water samples and over water samples (suspended particulates and dissolved fraction sampled by filtration) and air samples (aerosols and vapor phase sampled by filtration). All samples (except over watermore » and air) were collected at open sea in the Baltic. The analyses results have been used to make a model approach on the whole Baltic and to elucidate different aspects of the behavior of PAHs and PCBs in the Baltic, such as the occurrence of the compounds in water and sediment, the total content as well as the concentration variabilities over such a large geographical area, Further, the data on settling particulate matter as well as the air concentration data were used to estimate the total fluxes of PAHs and PCBs to the bottoms of the Baltic and t o the total water area of the Baltic, respectively. Further, data on the PAH and PCB content in river water from four major rivers provides rough estimates of the riverine input to the Baltic. The dynamics of PAHs and PCBs within the water mass have also been studied in terms of settling velocities and residence times in the water mass for these type of compounds in the open Baltic.« less

  3. Evaluation of a Dust Control for a Small Slab-Riding Dowel Drill for Concrete Pavement

    PubMed Central

    Echt, Alan; Mead, Kenneth

    2016-01-01

    Purpose To assess the effectiveness of local exhaust ventilation to control respirable crystalline silica exposures to acceptable levels during concrete dowel drilling. Approach Personal breathing zone samples for respirable dust and crystalline silica were collected while laborers drilled holes 3.5 cm diameter by 36 cm deep in a concrete slab using a single-drill slab-riding dowel drill equipped with local exhaust ventilation. Data were collected on air flow, weather, and productivity. Results All respirable dust samples were below the 90 µg detection limit which, when combined with the largest sample volume, resulted in a minimum detectable concentration of 0.31 mg m−3. This occurred in a 32-min sample collected when 27 holes were drilled. Quartz was only detected in one air sample; 0.09 mg m−3 of quartz was found on an 8-min sample collected during a drill maintenance task. The minimum detectable concentration for quartz in personal air samples collected while drilling was performed was 0.02 mg m−3. The average number of holes drilled during each drilling sample was 23. Over the course of the 2-day study, air flow measured at the dust collector decreased from 2.2 to 1.7 m3 s−1. Conclusions The dust control performed well under the conditions of this test. The initial duct velocity with a clean filter was sufficient to prevent settling, but gradually fell below the recommended value to prevent dust from settling in the duct. The practice of raising the drill between each hole may have prevented the dust from settling in the duct. A slightly higher flow rate and an improved duct design would prevent settling without regard to the position of the drill. PMID:26826033

  4. Evaluation of a Dust Control for a Small Slab-Riding Dowel Drill for Concrete Pavement.

    PubMed

    Echt, Alan; Mead, Kenneth

    2016-05-01

    To assess the effectiveness of local exhaust ventilation to control respirable crystalline silica exposures to acceptable levels during concrete dowel drilling. Personal breathing zone samples for respirable dust and crystalline silica were collected while laborers drilled holes 3.5 cm diameter by 36 cm deep in a concrete slab using a single-drill slab-riding dowel drill equipped with local exhaust ventilation. Data were collected on air flow, weather, and productivity. All respirable dust samples were below the 90 µg detection limit which, when combined with the largest sample volume, resulted in a minimum detectable concentration of 0.31 mg m(-3). This occurred in a 32-min sample collected when 27 holes were drilled. Quartz was only detected in one air sample; 0.09 mg m(-3) of quartz was found on an 8-min sample collected during a drill maintenance task. The minimum detectable concentration for quartz in personal air samples collected while drilling was performed was 0.02 mg m(-3). The average number of holes drilled during each drilling sample was 23. Over the course of the 2-day study, air flow measured at the dust collector decreased from 2.2 to 1.7 m(3) s(-1). The dust control performed well under the conditions of this test. The initial duct velocity with a clean filter was sufficient to prevent settling, but gradually fell below the recommended value to prevent dust from settling in the duct. The practice of raising the drill between each hole may have prevented the dust from settling in the duct. A slightly higher flow rate and an improved duct design would prevent settling without regard to the position of the drill. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2016.

  5. Fungal burden exposure assessment in podiatry clinics from Ireland.

    PubMed

    Viegas, Carla; Coggins, Ann Marie; Faria, Tiago; Caetano, Liliana Aranha; Gomes, Anita Quintal; Sabino, Raquel; Verissimo, Cristina; Roberts, Nigel; Watterson, David; MacGilchrist, Claire; Fleming, Gerard T A

    2018-03-26

    Fungi are amongst the bioaerosols of most importance, as indicated by the growing interest in this field of research. The aim was to characterize the exposure to fungal burden in podiatry clinics using culture-based and molecular methods. Airborne fungi were collected using an impaction air sampler and surface samples were also performed. Fourteen air samples were collected for direct detection of fungal DNA from filamentous fungi and dermatophytes. Overall, 63.6 % of the evening samples and 46 % of the morning samples surpassed the threshold values (150 CFU/m 3 ). Molecular detection, by real time PCR, of the target fungal species/strains (Aspergillus and Stachybotrys species) was negative for all samples collected. Trichophyton rubrum was detected by PCR analysis in one DNA sample collected on day six. Results suggest the use of both culture-based and molecular methodologies are desirable for a complete evaluation of fungal burden in this particular health care setting.

  6. Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marberry, Hugh; Moore, Winston

    2013-07-01

    Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate inputmore » errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)« less

  7. SOURCES OF PCBS TO THE ATMOSPHERE IN CHICAGO

    EPA Science Inventory

    The project will obtain additional short-term PCB samples in southwestern Chicago to determine the amount of PCB emissions to the air from a sludge drying facility. Four different types of samples will be collected: (1) short-term ambient air samples surrounding the drying beds,...

  8. Air quality during demolition and recovery activities in post-Katrina New Orleans.

    PubMed

    Ravikrishna, Raghunathan; Lee, Han-Woong; Mbuligwe, Stephen; Valsaraj, K T; Pardue, John H

    2010-07-01

    Air samples were collected during demolition and cleanup operations in the Lakeview district of New Orleans, Louisiana, USA, in late 2005 during the period immediately after Hurricane Katrina. Three different high-volume air samples were collected around waste collection areas that were created to temporarily hold the debris from the cleanup of residential properties in the area. Particulate concentrations were elevated and included crystalline fibers associated with asbestos. Metal concentrations on particulate matter resembled those measured in sediments deposited by floodwaters with the exception of Ba, which was elevated at all three locations. The highest organic contaminant concentration measured on particulates was the pesticide Ziram (Zinc, bis[diethylcarbamodithioato-S,S']-, [T-4]-) at 2,200 microg/g of particulate matter during sampling period 2. Ziram is used in latex paint, adhesives, caulking, and wallboard as a preservative. Fungal isolates developed from particulate air samples included species associated with disease including Aspergillus and Penicillium species. These data represent the most comprehensive assessment of demolition activities during the period immediately after Hurricane Katrina. Copyright (c) 2010 SETAC.

  9. EVALUATION OF THE FILTER PACK FOR LONG-DURATION SAMPLING OF AMBIENT AIR

    EPA Science Inventory

    A 14-week filter pack (FP) sampler evaluation field study was conducted at a site near Bondville, IL to investigate the impact of weekly sampling duration. Simultaneous samples were collected using collocated filter packs (FP) from two independent air quality monitoring networks...

  10. NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR VOCS IN REPLICATES

    EPA Science Inventory

    This data set includes analytical results for measurements of VOCs in 204 duplicate (replicate) samples. Measurements were made for up to 23 VOCs in samples of air, water, and blood. Duplicate samples (samples collected along with or next to the original samples) were collected t...

  11. Concentration and characteristics of depleted uranium in water, air and biological samples collected in Serbia and Montenegro.

    PubMed

    Jia, Guogang; Belli, Maria; Sansone, Umberto; Rosamilia, Silvia; Gaudino, Stefania

    2005-09-01

    During the Balkan conflicts, in 1995 and 1999, depleted uranium (DU) rounds were employed and were left in the battlefield. Health concern is related to the risk arising from contamination of the environment with DU penetrators and dust. In order to evaluate the impact of DU on the environment and population in Serbia and Montenegro, radiological surveys of DU in water, air and biological samples were carried out over the period 27 October-5 November 2001. The uranium isotopic concentrations in biological samples collected in Serbia and Montenegro, mainly lichens and barks, were found to be in the range of 0.67-704 Bqkg(-1) for (238)U, 0.48-93.9 Bqkg(-1) for (234)U and 0.02-12.2 Bqkg(-1) for (235)U, showing uranium levels to be higher than in the samples collected at the control sites. Moreover, (236)U was detectable in some of the samples. The isotopic ratios of (234)U/(238)U showed DU to be detectable in many biological samples at all examined sites, especially in Montenegro, indicating widespread ground-surface DU contamination, albeit at very low level. The uranium isotopic concentrations in air obtained from the air filter samples collected in Serbia and Montenegro were found to be in the range of 1.99-42.1 microBqm(-3) for (238)U, 0.96-38.0 microBqm(-3) for (234)U, and 0.05-1.83 microBqm(-3) for (235)U, being in the typical range of natural uranium values. Thus said, most of the air samples are DU positive, this fact agreeing well with the widespread DU contamination detected in the biological samples. The uranium concentrations in water samples collected in Serbia and Montenegro were found to be in the range of 0.40-21.9 mBql(-1) for (238)U, 0.27-28.1 mBql(-1) for (234)U, and 0.01-0.88 mBql(-1) for (235)U, these values being much lower than those in mineral water found in central Italy and below the WHO guideline for drinking water. From a radiotoxicological point of view, at this moment there is no significant radiological risk related to these investigated sites in terms of possible DU contamination of water, air and/or plants.

  12. An Improved, Automated Whole-Air Sampler and VOC Analysis System: Results from SONGNEX 2015

    NASA Astrophysics Data System (ADS)

    Lerner, B. M.; Gilman, J.; Tokarek, T. W.; Peischl, J.; Koss, A.; Yuan, B.; Warneke, C.; Isaacman-VanWertz, G. A.; Sueper, D.; De Gouw, J. A.; Aikin, K. C.

    2015-12-01

    Accurate measurement of volatile organic compounds (VOCs) in the troposphere is critical for the understanding of emissions and physical and chemical processes that can impact both air quality and climate. Airborne VOC measurements have proven challenging due to the requirements of short sample collection times (=10 s) to maximize spatial resolution and sampling frequency and high sensitivity (pptv) to chemically diverse hydrocarbons, halocarbons, oxygen- and nitrogen-containing VOCs. NOAA ESRL CSD has built an improved whole air sampler (iWAS) which collects compressed ambient air samples in electropolished stainless steel canisters, based on the NCAR HAIS Advanced Whole Air Sampler [Atlas and Blake]. Post-flight chemical analysis is performed with a custom-built gas chromatograph-mass spectrometer system that pre-concentrates analyte cryostatically via a Stirling cooler, an electromechanical chiller which precludes the need for liquid nitrogen to reach trapping temperatures. For the 2015 Shale Oil and Natural Gas Nexus Study (SONGNEX), CSD conducted iWAS measurements on 19 flights aboard the NOAA WP-3D aircraft between March 19th and April 27th. Nine oil and natural gas production regions were surveyed during SONGNEX and more than 1500 air samples were collected and analyzed. For the first time, we employed real-time mapping of sample collection combined with live data from fast time-response measurements (e.g. ethane) for more uniform surveying and improved target plume sampling. Automated sample handling allowed for more than 90% of iWAS canisters to be analyzed within 96 hours of collection - for the second half of the campaign improved efficiencies reduced the median sample age at analysis to 36 hours. A new chromatography peak-fitting software package was developed to minimize data reduction time by an order of magnitude without a loss of precision or accuracy. Here we report mixing ratios for aliphatic and aromatic hydrocarbons (C2-C8) along with select oxygenated species (alcohols and ketones) and cycloalkanes. We present an intercomparison of the GC-MS analysis system and iWAS samples from SONGNEX with a new H3O+ CIMS-TOF and a spectroscopic ethane measurement that also flew aboard the NOAA WP-3D aircraft during SONGNEX. We also consider the effect of sample age on observed mixing ratio.

  13. Nonmethane organic compound monitoring program. Final report 1988. Volume 2. Urban air toxics monitoring program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McAllister, R.A.; Moore, W.H.; Rice, J.

    1989-04-01

    From October, 1987 to October, 1988 samples of ambient air were collected at 19 sites in the eastern part of the U.S. Every 12 days, air was integrated over 24-hour periods into passivated stainless steel canisters. Simultaneously, air was drawn through cartridges containing dinitrophenylhydrazine to collect carbonyl compounds. The samples were analyzed at a central laboratory for a total of 37 halogenated and aromatic hydrocarbons, formaldehyde, acetaldehyde, and other oxygenated species. The hydrocarbon species were analyzed by gas chromatography/multiple detectors and gas chromatography/mass spectrometry, while the carbonyl species were analyzed by liquid chromatography. An extensive quality assurance program was carriedmore » on to secure high quality data. Complete data for all the hydrocarbon samples are presented in the report.« less

  14. Quantification and spread of Pneumocystis jirovecii in the surrounding air of patients with Pneumocystis pneumonia.

    PubMed

    Choukri, Firas; Menotti, Jean; Sarfati, Claudine; Lucet, Jean-Christophe; Nevez, Gilles; Garin, Yves J F; Derouin, Francis; Totet, Anne

    2010-08-01

    Airborne transmission of Pneumocystis has been demonstrated in animal models and is highly probable in humans. However, information concerning burdens of Pneumocystis jirovecii (human-derived Pneumocystis) in exhaled air from infected patients is lacking. Our objective is to evaluate P. jirovecii air diffusion in patients with Pneumocystis pneumonia. Patients admitted with Pneumocystis pneumonia were prospectively enrolled from 9 January 2008 to 21 July 2009. Air samples (1.5 m(3)) were collected on liquid medium with a commercial sampler at 1-, 3-, 5-, and 8-m distances from patients' heads. Air control samples were collected away from Pneumocystis pneumonia patient wards and outdoors. Samples were examined for P. jirovecii detection and quantification using a real-time polymerase chain reaction assay targeting the mitochondrial large subunit ribosomal RNA gene. Forty patients were diagnosed as having Pneumocystis pneumonia. Air sampling was performed in the environment for 19 of them. At a 1-m distance from patients' heads, P. jirovecii DNA was detected in 15 (79.8%) of 19 patients, with fungal burdens ranging from 7.5 X 10³ to 4.5 X 10⁶ gene copies/m(3). These levels decreased with distance from the patients (P < .002). Nevertheless, 4 (33.3%) of the 12 samples taken at 8 m, in the corridor adjacent to their room, were still positive. Forty control samples were collected and remained negative. This study provides the first quantitative data on the spread of P. jirovecii in exhaled air from infected patients. It sustains the risk of P. jirovecii direct transmission in close contact with patients with Pneumocystis pneumonia and leads the way for initiating a quantitative risk assessment for airborne transmission of P. jirovecii.

  15. Relationship between vapor intrusion and human exposure to trichloroethylene.

    PubMed

    Archer, Natalie P; Bradford, Carrie M; Villanacci, John F; Crain, Neil E; Corsi, Richard L; Chambers, David M; Burk, Tonia; Blount, Benjamin C

    2015-01-01

    Trichloroethylene (TCE) in groundwater has the potential to volatilize through soil into indoor air where it can be inhaled. The purpose of this study was to determine whether individuals living above TCE-contaminated groundwater are exposed to TCE through vapor intrusion. We examined associations between TCE concentrations in various environmental media and TCE concentrations in residents. For this assessment, indoor air, outdoor air, soil gas, and tap water samples were collected in and around 36 randomly selected homes; blood samples were collected from 63 residents of these homes. Additionally, a completed exposure survey was collected from each participant. Environmental and blood samples were analyzed for TCE. Mixed model multiple linear regression analyses were performed to determine associations between TCE in residents' blood and TCE in indoor air, outdoor air, and soil gas. Blood TCE concentrations were above the limit of quantitation (LOQ; ≥ 0.012 µg L(-1)) in 17.5% of the blood samples. Of the 36 homes, 54.3%, 47.2%, and >84% had detectable concentrations of TCE in indoor air, outdoor air, and soil gas, respectively. Both indoor air and soil gas concentrations were statistically significantly positively associated with participants' blood concentrations (P = 0.0002 and P = 0.04, respectively). Geometric mean blood concentrations of residents from homes with indoor air concentrations of >1.6 µg m(-3) were approximately 50 times higher than geometric mean blood TCE concentrations in participants from homes with no detectable TCE in indoor air (P < .0001; 95% CI 10.4-236.4). This study confirms the occurrence of vapor intrusion and demonstrates the magnitude of exposure from vapor intrusion of TCE in a residential setting.

  16. Relationship between vapor intrusion and human exposure to trichloroethylene

    PubMed Central

    ARCHER, NATALIE P.; BRADFORD, CARRIE M.; VILLANACCI, JOHN F.; CRAIN, NEIL E.; CORSI, RICHARD L.; CHAMBERS, DAVID M.; BURK, TONIA; BLOUNT, BENJAMIN C.

    2015-01-01

    Trichloroethylene (TCE) in groundwater has the potential to volatilize through soil into indoor air where it can be inhaled. The purpose of this study was to determine whether individuals living above TCE-contaminated groundwater are exposed to TCE through vapor intrusion. We examined associations between TCE concentrations in various environmental media and TCE concentrations in residents. For this assessment, indoor air, outdoor air, soil gas, and tap water samples were collected in and around 36 randomly selected homes; blood samples were collected from 63 residents of these homes. Additionally, a completed exposure survey was collected from each participant. Environmental and blood samples were analyzed for TCE. Mixed model multiple linear regression analyses were performed to determine associations between TCE in residents' blood and TCE in indoor air, outdoor air, and soil gas. Blood TCE concentrations were above the limit of quantitation (LOQ; ≥0.012 μg/L) in 17.5% of the blood samples. Of the 36 homes, 54.3%, 47.2%, and >84% had detectable concentrations of TCE in indoor air, outdoor air, and soil gas, respectively. Both indoor air and soil gas concentrations were statistically significantly positively associated with participants' blood concentrations (p=0.0002 and p=0.04, respectively). Geometric mean blood concentrations of residents from homes with indoor air concentrations of >1.6 μg/m3 were approximately 50 times higher than geometric mean blood TCE concentrations in participants from homes with no detectable TCE in indoor air (p<.0001; 95% CI 10.4 – 236.4). This study confirms the occurrence of vapor intrusion and demonstrates the magnitude of exposure from vapor intrusion of TCE in a residential setting. PMID:26259926

  17. Determination of Water Soluble Organic Carbon Collected ~1 km above the Earth's Surface during a Mid-Atlantic Air Quality Episode and Comparison to Aerosol Optical Properties

    NASA Astrophysics Data System (ADS)

    Brent, L. C.; He, H.; Arkinson, H. L.; Stehr, J. W.; Ring, A.; Marufu, L.; Reiner, J.; Sander, L. C.; Dickerson, R. R.

    2014-12-01

    Routine, light aircraft air-monitoring conducted in MD provides insight into atmospheric photochemical processing as a function of altitude in the boundary layer and lower free troposphere. We present correlations between the optical properties and chemical composition of aerosols at ~1 km altitude over Maryland. Data were collected during the peak smog day and a dissipation day during an air quality episode studied in DISCOVER-AQ, July 2011. Post flight filter sample analysis shows a positive trend between measurable carboxylate concentrations and particle size with a recirculating, aged, urban air mass influenced with southeasterly marine winds (peak day). A westerly influx of air from the Ohio River Valley on the dissipation day was depleted in carboxylates compared with samples collected over the same location two days prior. These samples contained quantifiable concentrations of cis-pinonic acid, a reaction product of pinene after ozonation and photochemical oxidation. New techniques were developed to improve airborne data collection and analysis of water soluble organic acids (WSOA), a frequently dominant fraction of particulate matter (PM). An ion chromatographic mass spectrometric method was developed using NIST Standard Referencing Material 1649b, Urban Dust, as a surrogate material to achieve separation and resolution of at least 34 organic acids. Analysis of aircraft filter samples resulted in detection of 16 organic acids of which 12 were quantified. Eight inorganic species were also quantified. Aged, re-circulated metropolitan air showed a greater number of dicarboxylic acids than new transport air from the west and may provide a useful test of SOA formation theory.

  18. Determination of 14C/ 12C of acetaldehyde in indoor air by compound specific radiocarbon analysis

    NASA Astrophysics Data System (ADS)

    Kato, Yoshimi; Shinohara, Naohide; Yoshinaga, Jun; Uchida, Masao; Matsuda, Ayuri; Yoneda, Minoru; Shibata, Yasuyuki

    A method of compound-specific radiocarbon analysis (CSRA) for acetaldehyde in indoor air was established for the source apportionment purpose and the methodology was applied to indoor air samples. Acetaldehyde in indoor air samples was collected using the conventional 2,4-dinitrophenylhydrazine (DNPH) derivatization method. Typically 24-h air sampling at 5-10 L min -1 allowed collection of adequate amount of acetaldehyde for radiocarbon analysis by accelerator mass spectrometry (AMS). The 14C abundance of acetaldehyde in indoor air was measured by AMS after solvent extraction of derivatized acetaldehyde and sequential purification by a preparative liquid chromatography system and a preparative capillary gas chromatography system. The recovery and purity of the derivatized acetaldehyde was satisfactory for 14C analysis by AMS. 14C abundance of acetaldehyde was calculated by considering that of derivatizing agent DNPH. Our preliminary survey showed that percent modern carbon (pMC) values of acetaldehyde isolated from indoor air sampled in newly built, unoccupied housings ( n=5) in the suburb of Tokyo ranged from 49.4 to 67.0. This result indicated that contribution of anthropogenic source was greater than previously expected.

  19. Identification and quantification of indoor air pollutant sources within a residential academic campus.

    PubMed

    Suryawanshi, Shalini; Chauhan, Amit Singh; Verma, Ritika; Gupta, Tarun

    2016-11-01

    There is a growing concern regarding the adverse health effects due to indoor air pollution in developing countries including India. Hence, it becomes important to study the causes and sources of indoor air pollutants. This study presents the indoor concentrations of PM0.6 (particles with aerodynamic diameter less than 0.6μm) and identifies sources leading to indoor air pollution. Indoor air samples were collected at IIT Kanpur campus. Ninety-eight PM0.6 samples were collected during November 2013 to September 2014. PM0.6 concentration was measured using a single stage impactor type PM0.6 sampler. The average PM0.6 concentration indoor was about 94.44μg/m(3). Samples collected were then analysed for metal concentrations using ICP-OES (Inductively Coupled Plasma - Optical Emission Spectrometer). Eight metals Ba, Ca, Cr, Cu, Fe, Mg, Ni and Pb were quantified from PM samples using ICP-OES. Positive Matrix Factorization (PMF) was used for source apportionment of indoor air pollution. PMF is a factor analysis tool which helps in resolving the profile and contribution of the sources from an unknown mixture. Five possible sources of indoor pollutants were identified by factor analysis - (1) Coal combustion (21.8%) (2) Tobacco smoking (9.8%) (3) Wall dust (25.7%) (4) Soil particles (17.5%) (5) Wooden furniture/paper products (25.2%). Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Whole Air Sampling During NASA's March-April 1999 Pacific Exploratory Expedition (PEM-Tropics B)

    NASA Technical Reports Server (NTRS)

    Blake, Donald R.

    2001-01-01

    University of California, Irvine (UCI) collected more than 4500 samples whole air samples collected over the remote Pacific Ocean during NASA's Global Tropospheric Experiment (GTE) Pacific Exploratory Mission-Tropics B (PEM-Tropics B) in March and early April 1999. Approximately 140 samples during a typical 8-hour DC-8 flight, and 120 canisters for each 8-hour flight aboard the P-3B. These samples were obtained roughly every 3-7 min during horizontal flight legs and 1-3 min during vertical legs. The filled canisters were analyzed in the laboratory at UCI within ten days of collection. The mixing ratios of 58 trace gases comprising hydrocarbons, halocarbons, alkyl nitrates and DMS were reported (and archived) for each sample. Two identical analytical systems sharing the same standards were operated simultaneously around the clock to improve canister turn-around time and to keep our measurement precision optimal. This report presents a summary of the results for sample collected.

  1. Bioaerosol emissions and detection of airborne antibiotic resistance genes from a wastewater treatment plant

    NASA Astrophysics Data System (ADS)

    Li, Jing; Zhou, Liantong; Zhang, Xiangyu; Xu, Caijia; Dong, Liming; Yao, Maosheng

    2016-01-01

    Air samples from twelve sampling sites (including seven intra-plant sites, one upwind site and four downwind sites) from a wastewater treatment plant (WWTP) in Beijing were collected using a Reuter Centrifugal Sampler High Flow (RCS); and their microbial fractions were studied using culturing and high throughput gene sequence. In addition, the viable (fluorescent) bioaerosol concentrations for 7 intra-plant sites were also monitored for 30 min each using an ultraviolet aerodynamic particle sizer (UV-APS). Both air and water samples collected from the plant were investigated for possible bacterial antibiotic resistance genes and integrons using polymerase chain reaction (PCR) coupled with gel electrophoresis. The results showed that the air near sludge thickening basin was detected to have the highest level of culturable bacterial aerosols (up to 1697 CFU/m3) and fungal aerosols (up to 930 CFU/m3). For most sampling sites, fluorescent peaks were observed at around 3-4 μm, except the office building with a peak at 1.5 μm, with a number concentration level up to 1233-6533 Particles/m3. About 300 unique bacterial species, including human opportunistic pathogens, such as Comamonas Testosteroni and Moraxella Osloensis, were detected from the air samples collected over the biological reaction basin. In addition, we have detected the sul2 gene resistant to cotrimoxazole (also known as septra, bactrim and TMP-SMX) and class 1 integrase gene from the air samples collected from the screen room and the biological reaction basin. Overall, the screen room, sludge thickening basin and biological reaction basin imposed significant microbial exposure risks, including those from airborne antibiotic resistance genes.

  2. Microbiota and Particulate Matter Assessment in Portuguese Optical Shops Providing Contact Lens Services

    PubMed Central

    Viegas, Carla; Faria, Tiago; Pacífico, Cátia; Dos Santos, Mateus; Monteiro, Ana; Lança, Carla; Carolino, Elisabete; Viegas, Susana; Cabo Verde, Sandra

    2017-01-01

    The aim of this work was to assess the microbiota (fungi and bacteria) and particulate matter in optical shops, contributing to a specific protocol to ensure a proper assessment. Air samples were collected through an impaction method. Surface and equipment swab samples were also collected side-by-side. Measurements of particulate matter were performed using portable direct-reading equipment. A walkthrough survey and checklist was also applied in each shop. Regarding air sampling, eight of the 13 shops analysed were above the legal requirement and 10 from the 26 surfaces samples were overloaded. In three out of the 13 shops fungal contamination in the analysed equipment was not detected. The bacteria air load was above the threshold in one of the 13 analysed shops. However, bacterial counts were detected in all sampled equipment. Fungi and bacteria air load suggested to be influencing all of the other surface and equipment samples. These results reinforce the need to improve air quality, not only to comply with the legal requirements, but also to ensure proper hygienic conditions. Public health intervention is needed to assure the quality and safety of the rooms and equipment in optical shops that perform health interventions in patients. PMID:28505144

  3. 40 CFR 86.537-90 - Dynamometer test runs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... phase of the test. Obtain methanol and formaldehyde sample analyses, if applicable, within 24 hours of... minutes of the end of the sample collection phase of the test. Obtain methanol and formaldehyde sample... the dilute exhaust and dilution air sample collection systems. (4) For methanol-fueled vehicles, with...

  4. 40 CFR 86.537-90 - Dynamometer test runs.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... phase of the test. Obtain methanol and formaldehyde sample analyses, if applicable, within 24 hours of... minutes of the end of the sample collection phase of the test. Obtain methanol and formaldehyde sample... the dilute exhaust and dilution air sample collection systems. (4) For methanol-fueled vehicles, with...

  5. An automated atmospheric sampling system operating on 747 airliners

    NASA Technical Reports Server (NTRS)

    Perkins, P.; Gustafsson, U. R. C.

    1975-01-01

    An air sampling system that automatically measures the temporal and spatial distribution of selected particulate and gaseous constituents of the atmosphere has been installed on a number of commercial airliners and is collecting data on commercial air routes covering the world. Measurements of constituents related to aircraft engine emissions and other pollutants are made in the upper troposphere and lower stratosphere (6 to 12 km) in support of the Global Air Sampling Program (GASP). Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This system includes specialized instrumentation for measuring carbon monoxide, ozone, water vapor, and particulates, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituents and related flight data are tape recorded in flight for later computer processing on the ground.

  6. Urban-air-toxics Monitoring Program, 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-06-01

    From March 1990 through February 1991 samples of ambient air were collected at 12 sites in the eastern part of the U.S. Every 12 days, air was integrated over 24-hour periods into passivated stainless steel canisters. Simultaneously, air was drawn through cartridges containing dinitrophenylhydrazine to collect carbonyl compounds. The samples were analyzed at a central laboratory for a total of 37 halogenated and aromatic hydrocarbons, formaldehyde, acetaldehyde, and other oxygenated species. The hydrocarbon species were analyzed by gas chromatography/multiple detectors and gas chromatography/mass spectrometry, while the carbonyl species were analyzed by liquid chromatography. Complete data for all the hydrocarbon samplesmore » are presented in the report.« less

  7. Variability of indoor fungal microbiome of green and non-green low-income homes in Cincinnati, Ohio.

    PubMed

    Coombs, Kanistha; Taft, Diana; Ward, Doyle V; Green, Brett J; Chew, Ginger L; Shamsaei, Behrouz; Meller, Jaroslaw; Indugula, Reshmi; Reponen, Tiina

    2018-01-01

    "Green" housing is designed to use low-impact materials, increase energy efficiency and improve occupant health. However, little is known about the indoor mycobiome of green homes. The current study is a subset of a multicenter study that aims to investigate the indoor environment of green homes and the respiratory health of asthmatic children. In the current study, the mycobiome in air, bed dust and floor dust was compared between green (study site) and non-green (control site), low-income homes in Cincinnati, Ohio. The samples were collected at baseline (within four months following renovation), and 12months after the baseline at the study site. Parallel sample collection was conducted in non-green control homes. Air samples were collected by PM2.5 samplers over 5-days. Bed and floor dust samples were vacuumed after the air sampling was completed. The DNA sample extracts were analyzed using ITS amplicon sequencing. Analysis indicated that there was no clear trend in the fungal communities between green and non-green homes. Instead, fungal community differences were greatest between sample types - air, bed, and floor. Microbial communities also changed substantially between sampling intervals in both green and non-green homes for all sample types, potentially indicating that there was very little stability in the mycobiomes. Research gaps remain regarding how indoor mycobiome fluctuates over time. Longer follow-up periods might elucidate the effect of green renovation on microbial load in buildings. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Apparatus and methods for monitoring the concentrations of hazardous airborne substances, especially lead

    DOEpatents

    Zaromb, Solomon

    2004-07-13

    Air is sampled at a rate in excess of 100 L/min, preferably at 200-300 L/min, so as to collect therefrom a substantial fraction, i.e., at least 20%, preferably 60-100%, of airborne particulates. A substance of interest (analyte), such as lead, is rapidly solubilized from the the collected particulates into a sample of liquid extractant, and the concentration of the analyte in the extractant sample is determined. The high-rate air sampling and particulate collection may be effected with a high-throughput filter cartridge or with a recently developed portable high-throughput liquid-absorption air sampler. Rapid solubilization of lead is achieved by a liquid extractant comprising 0.1-1 M of acetic acid or acetate, preferably at a pH of 5 or less and preferably with inclusion of 1-10% of hydrogen peroxide. Rapid determination of the lead content in the liquid extractant may be effected with a colorimetric or an electroanalytical analyzer.

  9. Atmospheric microbiology in the northern Caribbean during African dust events

    USGS Publications Warehouse

    Griffin, Dale W.; Kellogg, C.A.; Garrison, V.H.; Lisle, J.T.; Borden, T.C.; Shinn, E.A.

    2003-01-01

    Between July 2000 and August 2001 forty-three air samples were collected in the northern Caribbean: Twenty-six in the US Virgin Islands, and 17 samples aboard ship during two 1-week cruises. Samples were collected during African dust events and non-dust conditions and screened for the presence of culturable bacteria and fungi. A total of 3,652 liters of air were collected during non-dust conditions, with 19 bacteria and 28 fungi being recovered. During dust conditions a total of 2,369 liters of air were screened resulting in the recovery of 171 bacteria and 76 fungi. A statistically significant difference was found between the two data sets. These results support previous African dust research and further demonstrate that dust particles can serve as a vessel for the global dispersion of bacteria and fungi. Dustborne microorganisms may play a significant role in the ecology and health of downwind ecosystems.

  10. COMPARISON OF 24H AVERAGE VOC MONITORING RESULTS FOR RESIDENTIAL INDOOR AND OUTDOOR AIR USING CARBOPACK X-FILLED DIFFUSIVE SAMPLERS AND ACTIVE SAMPLING - A PILOT STUDY

    EPA Science Inventory

    Analytical results obtained by thermal desorption GC/MS for 24h diffusive sampling of 11 volatile organic compounds (VOCs) are compared with results of time-averaged active sampling at a known constant flow rate. Air samples were collected with co-located duplicate diffusive samp...

  11. Comparison of coarse coal dust sampling techniques in a laboratory-simulated longwall section.

    PubMed

    Patts, Justin R; Barone, Teresa L

    2017-05-01

    Airborne coal dust generated during mining can deposit and accumulate on mine surfaces, presenting a dust explosion hazard. When assessing dust hazard mitigation strategies for airborne dust reduction, sampling is done in high-velocity ventilation air, which is used to purge the mining face and gallery tunnel. In this environment, the sampler inlet velocity should be matched to the air stream velocity (isokinetic sampling) to prevent oversampling of coarse dust at low sampler-to-air velocity ratios. Low velocity ratios are often encountered when using low flow rate, personal sampling pumps commonly used in underground mines. In this study, with a goal of employing mine-ready equipment, a personal sampler was adapted for area sampling of coarse coal dust in high-velocity ventilation air. This was done by adapting an isokinetic nozzle to the inlet of an Institute of Occupational Medicine (Edinburgh, Scotland) sampling cassette (IOM). Collected dust masses were compared for the modified IOM isokinetic sampler (IOM-MOD), the IOM without the isokinetic nozzle, and a conventional dust sampling cassette without the cyclone on the inlet. All samplers were operated at a flow rate typical of personal sampling pumps: 2 L/min. To ensure differences between collected masses that could be attributed to sampler design and were not influenced by artifacts from dust concentration gradients, relatively uniform and repeatable dust concentrations were demonstrated in the sampling zone of the National Institute for Occupational Safety and Health experimental mine gallery. Consistent with isokinetic theory, greater differences between isokinetic and non-isokinetic sampled masses were found for larger dust volume-size distributions and higher ventilation air velocities. Since isokinetic sampling is conventionally used to determine total dust concentration, and isokinetic sampling made a difference in collected masses, the results suggest when sampling for coarse coal dust the IOM-MOD may improve airborne coarse dust assessments over "off-the-shelf" sampling cassettes.

  12. Comparison of coarse coal dust sampling techniques in a laboratory-simulated longwall section

    PubMed Central

    Patts, Justin R.; Barone, Teresa L.

    2017-01-01

    Airborne coal dust generated during mining can deposit and accumulate on mine surfaces, presenting a dust explosion hazard. When assessing dust hazard mitigation strategies for airborne dust reduction, sampling is done in high-velocity ventilation air, which is used to purge the mining face and gallery tunnel. In this environment, the sampler inlet velocity should be matched to the air stream velocity (isokinetic sampling) to prevent oversampling of coarse dust at low sampler-to-air velocity ratios. Low velocity ratios are often encountered when using low flow rate, personal sampling pumps commonly used in underground mines. In this study, with a goal of employing mine-ready equipment, a personal sampler was adapted for area sampling of coarse coal dust in high-velocity ventilation air. This was done by adapting an isokinetic nozzle to the inlet of an Institute of Occupational Medicine (Edinburgh, Scotland) sampling cassette (IOM). Collected dust masses were compared for the modified IOM isokinetic sampler (IOM-MOD), the IOM without the isokinetic nozzle, and a conventional dust sampling cassette without the cyclone on the inlet. All samplers were operated at a flow rate typical of personal sampling pumps: 2 L/min. To ensure differences between collected masses that could be attributed to sampler design and were not influenced by artifacts from dust concentration gradients, relatively uniform and repeatable dust concentrations were demonstrated in the sampling zone of the National Institute for Occupational Safety and Health experimental mine gallery. Consistent with isokinetic theory, greater differences between isokinetic and non-isokinetic sampled masses were found for larger dust volume-size distributions and higher ventilation air velocities. Since isokinetic sampling is conventionally used to determine total dust concentration, and isokinetic sampling made a difference in collected masses, the results suggest when sampling for coarse coal dust the IOM-MOD may improve airborne coarse dust assessments over “off-the-shelf” sampling cassettes. PMID:27792474

  13. Are We Biologically Safe with Snow Precipitation? A Case Study in Beijing

    PubMed Central

    Shen, Fangxia; Yao, Maosheng

    2013-01-01

    In this study, the bacterial and fungal abundances, diversities, conductance levels as well as total organic carbon (TOC) were investigated in the snow samples collected from five different snow occurrences in Beijing between January and March, 2010. The collected snow samples were melted and cultured at three different temperatures (4, 26 and 37°C). The culturable bacterial concentrations were manually counted and the resulting colony forming units (CFUs) at 26°C were further studied using V3 region of 16 S rRNA gene-targeted polymerase chain reaction -denaturing gradient gel electrophoresis (PCR-DGGE). The clone library was constructed after the liquid culturing of snow samples at 26°C. And microscopic method was employed to investigate the fungal diversity in the samples. In addition, outdoor air samples were also collected using mixed cellulose ester (MCE) filters and compared with snow samples with respect to described characteristics. The results revealed that snow samples had bacterial concentrations as much as 16000 CFU/ml for those cultured at 26°C, and the conductance levels ranged from 5.6×10−6 to 2.4×10−5 S. PCR-DGGE, sequencing and microscopic analysis revealed remarkable bacterial and fungal diversity differences between the snow samples and the outdoor air samples. In addition, DGGE banding profiles for the snow samples collected were also shown distinctly different from one another. Absent from the outdoor air, certain human, plant, and insect fungal pathogens were found in the snow samples. By calculation, culturable bacteria accounted for an average of 3.38% (±1.96%) of TOC for the snow samples, and 0.01% for that of outdoor air samples. The results here suggest that snow precipitations are important sources of fungal pathogens and ice nucleators, thus could affect local climate, human health and agriculture security. PMID:23762327

  14. Are we biologically safe with snow precipitation? A case study in beijing.

    PubMed

    Shen, Fangxia; Yao, Maosheng

    2013-01-01

    In this study, the bacterial and fungal abundances, diversities, conductance levels as well as total organic carbon (TOC) were investigated in the snow samples collected from five different snow occurrences in Beijing between January and March, 2010. The collected snow samples were melted and cultured at three different temperatures (4, 26 and 37°C). The culturable bacterial concentrations were manually counted and the resulting colony forming units (CFUs) at 26°C were further studied using V3 region of 16 S rRNA gene-targeted polymerase chain reaction -denaturing gradient gel electrophoresis (PCR-DGGE). The clone library was constructed after the liquid culturing of snow samples at 26°C. And microscopic method was employed to investigate the fungal diversity in the samples. In addition, outdoor air samples were also collected using mixed cellulose ester (MCE) filters and compared with snow samples with respect to described characteristics. The results revealed that snow samples had bacterial concentrations as much as 16000 CFU/ml for those cultured at 26°C, and the conductance levels ranged from 5.6×10(-6) to 2.4×10(-5) S. PCR-DGGE, sequencing and microscopic analysis revealed remarkable bacterial and fungal diversity differences between the snow samples and the outdoor air samples. In addition, DGGE banding profiles for the snow samples collected were also shown distinctly different from one another. Absent from the outdoor air, certain human, plant, and insect fungal pathogens were found in the snow samples. By calculation, culturable bacteria accounted for an average of 3.38% (±1.96%) of TOC for the snow samples, and 0.01% for that of outdoor air samples. The results here suggest that snow precipitations are important sources of fungal pathogens and ice nucleators, thus could affect local climate, human health and agriculture security.

  15. US EPA BASE Study Standard Operating Procedure for Sampling of Particulates

    EPA Pesticide Factsheets

    The objective of the procedure described is to collect a sample of particles of respirable and inhalable size (approx. 0.1 to 10 microns in diameter) from indoor air and from the outdoor air supplied to the indoor space tested.

  16. Decomposition Odour Profiling in the Air and Soil Surrounding Vertebrate Carrion

    PubMed Central

    2014-01-01

    Chemical profiling of decomposition odour is conducted in the environmental sciences to detect malodourous target sources in air, water or soil. More recently decomposition odour profiling has been employed in the forensic sciences to generate a profile of the volatile organic compounds (VOCs) produced by decomposed remains. The chemical profile of decomposition odour is still being debated with variations in the VOC profile attributed to the sample collection technique, method of chemical analysis, and environment in which decomposition occurred. To date, little consideration has been given to the partitioning of odour between different matrices and the impact this has on developing an accurate VOC profile. The purpose of this research was to investigate the decomposition odour profile surrounding vertebrate carrion to determine how VOCs partition between soil and air. Four pig carcasses (Sus scrofa domesticus L.) were placed on a soil surface to decompose naturally and their odour profile monitored over a period of two months. Corresponding control sites were also monitored to determine the VOC profile of the surrounding environment. Samples were collected from the soil below and the air (headspace) above the decomposed remains using sorbent tubes and analysed using gas chromatography-mass spectrometry. A total of 249 compounds were identified but only 58 compounds were common to both air and soil samples. This study has demonstrated that soil and air samples produce distinct subsets of VOCs that contribute to the overall decomposition odour. Sample collection from only one matrix will reduce the likelihood of detecting the complete spectrum of VOCs, which further confounds the issue of determining a complete and accurate decomposition odour profile. Confirmation of this profile will enhance the performance of cadaver-detection dogs that are tasked with detecting decomposition odour in both soil and air to locate victim remains. PMID:24740412

  17. Decomposition odour profiling in the air and soil surrounding vertebrate carrion.

    PubMed

    Forbes, Shari L; Perrault, Katelynn A

    2014-01-01

    Chemical profiling of decomposition odour is conducted in the environmental sciences to detect malodourous target sources in air, water or soil. More recently decomposition odour profiling has been employed in the forensic sciences to generate a profile of the volatile organic compounds (VOCs) produced by decomposed remains. The chemical profile of decomposition odour is still being debated with variations in the VOC profile attributed to the sample collection technique, method of chemical analysis, and environment in which decomposition occurred. To date, little consideration has been given to the partitioning of odour between different matrices and the impact this has on developing an accurate VOC profile. The purpose of this research was to investigate the decomposition odour profile surrounding vertebrate carrion to determine how VOCs partition between soil and air. Four pig carcasses (Sus scrofa domesticus L.) were placed on a soil surface to decompose naturally and their odour profile monitored over a period of two months. Corresponding control sites were also monitored to determine the VOC profile of the surrounding environment. Samples were collected from the soil below and the air (headspace) above the decomposed remains using sorbent tubes and analysed using gas chromatography-mass spectrometry. A total of 249 compounds were identified but only 58 compounds were common to both air and soil samples. This study has demonstrated that soil and air samples produce distinct subsets of VOCs that contribute to the overall decomposition odour. Sample collection from only one matrix will reduce the likelihood of detecting the complete spectrum of VOCs, which further confounds the issue of determining a complete and accurate decomposition odour profile. Confirmation of this profile will enhance the performance of cadaver-detection dogs that are tasked with detecting decomposition odour in both soil and air to locate victim remains.

  18. The lung cancer breath signature: a comparative analysis of exhaled breath and air sampled from inside the lungs

    NASA Astrophysics Data System (ADS)

    Capuano, Rosamaria; Santonico, Marco; Pennazza, Giorgio; Ghezzi, Silvia; Martinelli, Eugenio; Roscioni, Claudio; Lucantoni, Gabriele; Galluccio, Giovanni; Paolesse, Roberto; di Natale, Corrado; D'Amico, Arnaldo

    2015-11-01

    Results collected in more than 20 years of studies suggest a relationship between the volatile organic compounds exhaled in breath and lung cancer. However, the origin of these compounds is still not completely elucidated. In spite of the simplistic vision that cancerous tissues in lungs directly emit the volatile metabolites into the airways, some papers point out that metabolites are collected by the blood and then exchanged at the air-blood interface in the lung. To shed light on this subject we performed an experiment collecting both the breath and the air inside both the lungs with a modified bronchoscopic probe. The samples were measured with a gas chromatography-mass spectrometer (GC-MS) and an electronic nose. We found that the diagnostic capability of the electronic nose does not depend on the presence of cancer in the sampled lung, reaching in both cases an above 90% correct classification rate between cancer and non-cancer samples. On the other hand, multivariate analysis of GC-MS achieved a correct classification rate between the two lungs of only 76%. GC-MS analysis of breath and air sampled from the lungs demonstrates a substantial preservation of the VOCs pattern from inside the lung to the exhaled breath.

  19. New Noble Gas Studies on Popping Rocks from the Mid-Atlantic Ridge near 14°N

    NASA Astrophysics Data System (ADS)

    Kurz, M. D.; Curtice, J.; Jones, M.; Péron, S.; Wanless, V. D.; Mittelstaedt, E. L.; Soule, S. A.; Klein, F.; Fornari, D. J.

    2017-12-01

    New Popping Rocks were recovered in situ on the Mid-Atlantic Ridge (MAR) near 13.77° N, using HOV Alvin on cruise AT33-03 in 2016 on RV Atlantis. We report new helium, neon, argon, and CO2 step-crushing measurements on a subset of the glass samples, with a focus on a new procedure to collect seafloor samples with minimal exposure to air. Glassy seafloor basalts were collected in sealed containers using the Alvin mechanical arm and transported to the surface without atmospheric exposure. On the ship, the seawater was drained, the volcanic glass was transferred to stainless steel ultra-high-vacuum containers (in an oxygen-free glove box), which were then evacuated using a turbo-molecular pump and sealed for transport under vacuum. All processing was carried out under a nitrogen atmosphere. A control sample was collected from each pillow outcrop and processed normally in air. The preliminary step-crushing measurements show that the anaerobically collected samples have systematically higher 20Ne/22Ne, 21Ne/22Ne and 40Ar/36Ar than the control samples. Helium abundances and isotopes are consistent between anaerobically collected samples and control samples. These results suggest that minimizing atmospheric exposure during sample processing can significantly reduce air contamination for heavy noble gases, providing a new option for seafloor sampling. Higher vesicle abundances appear to yield a greater difference in neon and argon isotopes between the anaerobic and control samples, suggesting that atmospheric contamination is related to vesicle abundance, possibly through micro-fractures. The new data show variability in the maximum mantle neon and argon isotopic compositions, and abundance ratios, suggesting that the samples experienced variable outgassing prior to eruption, and may represent different phases of a single eruption, or multiple eruptions.

  20. A novel personal air sampling device for collecting volatile organic compounds: a comparison to charcoal tubes and diffusive badges.

    PubMed

    Rossner, Alan; Farant, Jean-Pierre

    2004-02-01

    Evacuated canisters have been used for many years to collect ambient air samples for gases and vapors. Recently, significant interest has arisen in using evacuated canisters for personal breathing zone sampling as an alternative to sorbent sampling. A novel flow control device was designed and built at McGill University. The flow control device was designed to provide a very low flow rate, <0.5 mL/min, to allow a sample to be collected over an extended period of time. Previous experiments run at McGill have shown agreement between the mathematical and empirical models to predict flow rate. The flow control device combined with an evacuated canister (capillary flow control-canister) was used in a series of experiments to evaluate its performance against charcoal tubes and diffusive badges. Air samples of six volatile organic compounds were simultaneously collected in a chamber using the capillary flow control-canister, charcoal tubes, and diffusive badges. Five different concentrations of the six volatile organic compounds were evaluated. The results from the three sampling devices were compared to each other and to concentration values obtained using an online gas chromatograph (GC). Eighty-four samples of each method were collected for each of the six chemicals. Results indicate that the capillary flow control-canister device compares quite favorably to the online GC and to the charcoal tubes, p > 0.05 for most of the tests. The capillary flow control-canister was found to be more accurate for the compounds evaluated, easier to use, and easier to analyze than charcoal tubes and passive dosimeter badges.

  1. Soil- and groundwater-quality data for petroleum hydrocarbon compounds within Fuels Area C, Ellsworth Air Force Base, South Dakota, 2014

    USGS Publications Warehouse

    Bender, David A.; Rowe, Barbara L.

    2015-01-01

    Ellsworth Air Force Base is an Air Combat Command located approximately 10 miles northeast of Rapid City, South Dakota. Ellsworth Air Force Base occupies about 6,000 acres within Meade and Pennington Counties, and includes runways, airfield operations, industrial areas, housing, and recreational facilities. Fuels Area C within Ellsworth Air Force Base is a fuels storage area that is used to support the mission of the base. In fall of 2013, the U.S. Geological Survey began a study in cooperation with the U.S. Air Force, Ellsworth Air Force Base, to estimate groundwater-flow direction, select locations for permanent monitoring wells, and install and sample monitoring wells for petroleum hydrocarbon compounds within Fuels Area C. Nine monitoring wells were installed for the study within Fuels Area C during November 4–7, 2014. Soil core samples were collected during installation of eight of the monitoring wells and analyzed for benzene, toluene, ethylbenzene, total xylenes, naphthalene,m- and p-xylene, o-xylene, and gasoline- and diesel-range organic compounds. Groundwater samples were collected from seven of the nine wells (two of the monitoring wells did not contain enough water to sample or were dry) during November 19–21, 2014, and analyzed for select physical properties, benzene, toluene, ethylbenzene, total xylenes, naphthalene, m- and p-xylene, o-xylene, and gasoline- and diesel-range organic compounds. This report describes the nine monitoring well locations and presents the soil- and groundwater-quality data collected in 2014 for this study.

  2. [Determination of diborane in the air of workplace by ICP-AES].

    PubMed

    Ding, Chun-Guang; Zhang, Jing; Yan, Hui-Fang

    2011-06-01

    A sampling method was established to collect diborane in the air of workplace and an ICP-AES method was developed to determine the Boron in desorbed solution. Diborane in the air of workplace was collected by solid sorbent tube filled with oxidant impregnated activated carbon. The adsorbed diborane was desorbed into 3% H2O2 aqueous, and then the desorbed Boron was determined by ICP-AES. The sampling efficiency of this method was 99.6% with the desorption efficiency of diborane with 5.660 microg and 56.6 microg spiked were 90.9% and 99.5%, respectively. Both the intra-and inter-precision RSD were less than 8%. The standard curve of this method ranged from 0.1 to 10.0 microg/ml (Boron), and the LOD and LOQ were 0.011 mg/m3 and 0.035 mg/m3 (15L samples) respectively. The method established was suitable for diborane sampling and determination in the air of workplace.

  3. Synthetic turf field investigation in Connecticut.

    PubMed

    Simcox, Nancy J; Bracker, Anne; Ginsberg, Gary; Toal, Brian; Golembiewski, Brian; Kurland, Tara; Hedman, Curtis

    2011-01-01

    The primary purpose of this study was to characterize the concentrations of volatile organic compounds (VOC), semivolatile organic compounds (SVOC), rubber-related chemicals such as benzothiazole (BZT) and nitrosamine, and particulate matter (PM(10)) in air at synthetic turf crumb rubber fields. Both new and older fields were evaluated under conditions of active use. Three types of fields were targeted: four outdoor crumb rubber fields, one indoor facility with crumb rubber turf, and an outdoor natural grass field. Background samples were collected at each field on grass. Personal air sampling was conducted for VOC, BZT, nitrosamines, and other chemicals. Stationary air samples were collected at different heights to assess the vertical profile of release. Air monitoring for PM(10) was conducted at one height. Bulk samples of turf grass and crumb rubber were analyzed, and meteorological data were recorded. Results showed that personal concentrations were higher than stationary concentrations and were higher on turf than in background samples for certain VOC. In some cases, personal VOC concentrations from natural grass fields were as high as those on turf. Naphthalene, BZT, and butylated hydroxytoluene (BHT) were detected in greater concentration at the indoor field compared to the outdoor fields. Nitrosamine air levels were below reporting levels. PM(10) air concentrations were not different between on-field and upwind locations. All bulk lead (Pb) samples were below the public health target of 400 ppm. More research is needed to better understand air quality at indoor facilities. These field investigation data were incorporated into a separate human health risk assessment.

  4. Indoor air quality in Latino homes in Boulder, Colorado

    NASA Astrophysics Data System (ADS)

    Escobedo, Luis E.; Champion, Wyatt M.; Li, Ning; Montoya, Lupita D.

    2014-08-01

    Indoor concentrations of airborne pollutants can be several times higher than those found outdoors, often due to poor ventilation, overcrowding, and the contribution of indoor sources within a home. Americans spend most of their time indoors where exposure to poor indoor air quality (IAQ) can result in diminished respiratory and cardiovascular health. This study measured the indoor air quality in 30 homes of a low-income Latino community in Boulder, Colorado during the summer of 2012. Participants were administered a survey, which included questions on their health conditions and indoor air pollution sources like cigarette smoke, heating fuel, and building materials. Twenty-four hour samples of fine particulate matter (PM2.5) from the indoor air were collected in each home; ambient PM2.5 samples were collected each day as well. Concurrent air samples were collected onto 47 mm Teflo and Tissuquartz filter at each location. Teflo filters were analyzed gravimetrically to measure PM2.5 and their extracts were used to determine levels of proteins and endotoxins in the fine fraction. The Tissuquartz filters were analyzed for elemental and organic carbon content (EC/OC). Results indicated that the indoor air contained higher concentrations of PM2.5 than the ambient air, and that the levels of OC were much higher than EC in both indoor and outdoor samples. This community showed no smoking in their homes and kept furry pets indoors at very low rates; therefore, cooking is likely the primary source of indoor PM. For responders with significant exposure to PM, it appeared to be primarily from occupational environments or childhood exposure abroad. Our findings indicate that for immigrant communities such as this, it is important to consider not only their housing conditions but also the relevant prior exposures when conducting health assessments.

  5. Method and apparatus for sampling atmospheric mercury

    DOEpatents

    Trujillo, Patricio E.; Campbell, Evan E.; Eutsler, Bernard C.

    1976-01-20

    A method of simultaneously sampling particulate mercury, organic mercurial vapors, and metallic mercury vapor in the working and occupational environment and determining the amount of mercury derived from each such source in the sampled air. A known volume of air is passed through a sampling tube containing a filter for particulate mercury collection, a first adsorber for the selective adsorption of organic mercurial vapors, and a second adsorber for the adsorption of metallic mercury vapor. Carbon black molecular sieves are particularly useful as the selective adsorber for organic mercurial vapors. The amount of mercury adsorbed or collected in each section of the sampling tube is readily quantitatively determined by flameless atomic absorption spectrophotometry.

  6. Collection of Viable Aerosolized Influenza Virus and Other Respiratory Viruses in a Student Health Care Center through Water-Based Condensation Growth

    PubMed Central

    Pan, Maohua; Bonny, Tania S.; Loeb, Julia; Jiang, Xiao; Eiguren-Fernandez, Arantzazu; Hering, Susanne; Fan, Z. Hugh; Wu, Chang-Yu

    2017-01-01

    ABSTRACT The dynamics and significance of aerosol transmission of respiratory viruses are still controversial, for the major reasons that virus aerosols are inefficiently collected by commonly used air samplers and that the collected viruses are inactivated by the collection method. Without knowledge of virus viability, infection risk analyses lack accuracy. This pilot study was performed to (i) determine whether infectious (viable) respiratory viruses in aerosols could be collected from air in a real world environment by the viable virus aerosol sampler (VIVAS), (ii) compare and contrast the efficacy of the standard bioaerosol sampler, the BioSampler, with that of the VIVAS for the collection of airborne viruses in a real world environment, and (iii) gain insights for the use of the VIVAS for respiratory virus sampling. The VIVAS operates via a water vapor condensation process to enlarge aerosolized virus particles to facilitate their capture. A variety of viable human respiratory viruses, including influenza A H1N1 and H3N2 viruses and influenza B viruses, were collected by the VIVAS located at least 2 m from seated patients, during a late-onset 2016 influenza virus outbreak. Whereas the BioSampler when operated following our optimized parameters also collected virus aerosols, it was nevertheless overall less successful based on a lower frequency of virus isolation in most cases. This side-by-side comparison highlights some limitations of past studies based on impingement-based sampling, which may have generated false-negative results due to either poor collection efficiency and/or virus inactivation due to the collection process. IMPORTANCE The significance of virus aerosols in the natural transmission of respiratory diseases has been a contentious issue, primarily because it is difficult to collect or sample virus aerosols using currently available air sampling devices. We tested a new air sampler based on water vapor condensation for efficient sampling of viable airborne respiratory viruses in a student health care center as a model of a real world environment. The new sampler outperformed the industry standard device (the SKC BioSampler) in the collection of natural virus aerosols and in maintaining virus viability. These results using the VIVAS indicate that respiratory virus aerosols are more prevalent and potentially pose a greater inhalation biohazard than previously thought. The VIVAS thus appears to be a useful apparatus for microbiology air quality tests related to the detection of viable airborne viruses. PMID:29034325

  7. Collection of Viable Aerosolized Influenza Virus and Other Respiratory Viruses in a Student Health Care Center through Water-Based Condensation Growth.

    PubMed

    Pan, Maohua; Bonny, Tania S; Loeb, Julia; Jiang, Xiao; Lednicky, John A; Eiguren-Fernandez, Arantzazu; Hering, Susanne; Fan, Z Hugh; Wu, Chang-Yu

    2017-01-01

    The dynamics and significance of aerosol transmission of respiratory viruses are still controversial, for the major reasons that virus aerosols are inefficiently collected by commonly used air samplers and that the collected viruses are inactivated by the collection method. Without knowledge of virus viability, infection risk analyses lack accuracy. This pilot study was performed to (i) determine whether infectious (viable) respiratory viruses in aerosols could be collected from air in a real world environment by the vi able v irus a erosol s ampler (VIVAS), (ii) compare and contrast the efficacy of the standard bioaerosol sampler, the BioSampler, with that of the VIVAS for the collection of airborne viruses in a real world environment, and (iii) gain insights for the use of the VIVAS for respiratory virus sampling. The VIVAS operates via a water vapor condensation process to enlarge aerosolized virus particles to facilitate their capture. A variety of viable human respiratory viruses, including influenza A H1N1 and H3N2 viruses and influenza B viruses, were collected by the VIVAS located at least 2 m from seated patients, during a late-onset 2016 influenza virus outbreak. Whereas the BioSampler when operated following our optimized parameters also collected virus aerosols, it was nevertheless overall less successful based on a lower frequency of virus isolation in most cases. This side-by-side comparison highlights some limitations of past studies based on impingement-based sampling, which may have generated false-negative results due to either poor collection efficiency and/or virus inactivation due to the collection process. IMPORTANCE The significance of virus aerosols in the natural transmission of respiratory diseases has been a contentious issue, primarily because it is difficult to collect or sample virus aerosols using currently available air sampling devices. We tested a new air sampler based on water vapor condensation for efficient sampling of viable airborne respiratory viruses in a student health care center as a model of a real world environment. The new sampler outperformed the industry standard device (the SKC BioSampler) in the collection of natural virus aerosols and in maintaining virus viability. These results using the VIVAS indicate that respiratory virus aerosols are more prevalent and potentially pose a greater inhalation biohazard than previously thought. The VIVAS thus appears to be a useful apparatus for microbiology air quality tests related to the detection of viable airborne viruses.

  8. GAS CHROMATOGRAPHIC METHOD FOR QUANTITATIVE DETERMINATION OF C2 TO C13 HYDROCARBONS IN ROADWAY VEHICLE EMISSIONS

    EPA Science Inventory

    A gas chromatographic system was used to quantitate more than 300 gas-phase hydrocarbons from background and roadside ambient air samples. Samples were simultaneously collected in Tedlar bags and on Tenax cartridges. Hydrocarbons from Tedlar bag-collected samples were quantitated...

  9. Atmospheric Carbon Dioxide Record from Mauna Loa (1958-2008)

    DOE Data Explorer

    Keeling, R. F. [Scripps Institution of Oceanography, University of California, La Jolla, California; Piper, S. C. [Scripps Institution of Oceanography, University of California, La Jolla, California; Bollenbacher, A. F. [Scripps Institution of Oceanography, University of California, La Jolla, California; Walker, J. S. [Scripps Institution of Oceanography, University of California, La Jolla, California

    2009-02-01

    Air samples at Mauna Loa are collected continuously from air intakes at the top of four 7-m towers and one 27-m tower. Four air samples are collected each hour for the purpose of determining the CO2 concentration. Determinations of CO2 are made by using a Siemens Ultramat 3 nondispersive infrared gas analyzer with a water vapor freeze trap. This analyzer registers the concentration of CO2 in a stream of air flowing at ~0.5 L/min. Every 30 minutes, the flow is replaced by a stream of calibrating gas or "working reference gas". In December 1983, CO2-in-N2 calibration gases were replaced with the currently used CO2-in-air calibration gases. These calibration gases and other reference gases are compared periodically to determine the instrument sensitivity and to check for possible contamination in the air-handling system. These reference gases are themselves calibrated against specific standard gases whose CO2 concentrations are determined manometrically. Greater details about the sampling methods at Mauna Loa are given in Keeling et al. (1982) and Keeling et al. (2002).

  10. Determination of polybrominated diphenyl ethers (PBDEs) in dust samples collected in air conditioning filters of different usage - method development.

    PubMed

    Śmiełowska, M; Zabiegała, B

    2018-06-19

    This study presents the results of studies aimed at the development of an analytical procedure for separation, identification, and determination of PBDEs compounds in dust samples collected from automotive cabin air filters and samples collected from filters installed as part of the air purification system in academic facilities. Ultrasound-assisted dispersive solid phase extraction (UA-dSPE) was found to perform better in terms of extract purification than the conventional SPE technique. GC-EIMS was used for final determination of analytes. The concentrations of PBDEs in car filters ranged from < LOD to 688 ng/g while from < LOD to 247 ng/g in dust from air conditioning filters. BDE-47 and BDE-100 were reported the dominating congeners. The estimated exposure to PBDEs via ingestion of dust from car filters varied from 0.00022 to 0.012 ng/day in toddlers and from 0.000036 to 0.0029 ng/day in adults; dust from air conditioning filters: from 0.017 to 0.25 ng/day in toddlers and from 0.0029 to 0.042 ng/day. In addition, an attempt was made at extracting PBDEs from a dust samples using the matrix solid-phase dispersion (MSPD) technique as a promising alternative to conventional SPE separations. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. A multiresidue method by high performance liquid chromatography-based fractionation and gas chromatographic determination of trace levels of pesticides in air and water.

    PubMed

    Seiber, J N; Glotfelty, D E; Lucas, A D; McChesney, M M; Sagebiel, J C; Wehner, T A

    1990-01-01

    A multiresidue analytical method is described for pesticides, transformation products, and related toxicants based upon high performance liquid chromatographic (HPLC) fractionation of extracted residue on a Partisil silica gel normal phase column followed by selective-detector gas chromatographic (GC) determination of components in each fraction. The HPLC mobile phase gradient (hexane to methyl t-butyl ether) gave good chromatographic efficiency, resolution, reproducibility and recovery for 61 test compounds, and allowed for collection in four fractions spanning polarities from low polarity organochlorine compounds (fraction 1) to polar N-methylcarbamates and organophosphorus oxons (fraction 4). The multiresidue method was developed for use with air samples collected on XAD-4 and related trapping agents, and water samples extracted with methylene chloride. Detection limits estimated from spiking experiments were generally 0.3-1 ng/m3 for high-volume air samples, and 0.01-0.1 microgram/L for one-liter water samples. Applications were made to determination of pesticides in fogwater and air samples.

  12. Long-term observation of water-soluble chemical components in the bulk atmospheric aerosols collected at Okinawa, Japan

    NASA Astrophysics Data System (ADS)

    Handa, Daishi; Somada, Yuka; Ijyu, Moriaki; Azechi, Sotaro; Nakaema, Fumiya; Arakaki, Takemitsu; Tanahara, Akira

    2010-05-01

    The economic development and population growth in recent Asia spread air pollution. Emission rate of air pollutants from Asia, in particular oxides of nitrogen, surpassed those from North America and Europe and should continue to exceed them for decades. The study of the long-range transported air pollution from Asian continent has gained a special attention in Japan because of increase in photochemical oxidants in relatively remote islands. Okinawa Island is situated approximately 1500 km south of Tokyo, Japan, 2000 km southeast of Beijing, China, and 1000 km south of South Korea. Its location in Asia is well suited for studying long-range transport of air pollutants in East Asia because maritime air mass prevails during summer, while continental air mass dominates during fall, winter, and spring. The maritime air mass data can be seen as background and can be compared with continental air masses which have been affected by anthropogenic activities. Bulk aerosol samples were collected on quartz filters by using a high volume air sampler. Sampling duration was one week for each sample. We determined the concentrations of water-soluble anions, cations and dissolved organic carbon (DOC) in the bulk aerosols collected at the Cape Hedo Atmosphere and Aerosol Monitoring Station (CHAAMS) using ion chromatography, atomic absorption spectrometry, and total organic carbon analyzer, respectively. We will report water-soluble chemical components data of anions, cations and DOC in bulk atmospheric aerosols collected at CHAAMS during August, 2005 to April, 2010. Seasonal variation of water-soluble chemical components showed that the concentrations were relatively low in summer, higher in fall and winter, and the highest in spring. When air mass came from Asian Continent, the concentrations of water-soluble chemical components were much higher compared to the other directions. In addition, we calculated background concentration of water-soluble chemical components at Okinawa, Japan.

  13. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR USE OF THE ACTIVE VOC SAMPLER FOR THE COLLECTION OF AIRBORNE VOCS AT FIXED INDOOR AND OUTDOOR SITES (UA-F-11.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used to collect indoor and outdoor air samples for the determination of selected volatile organic compounds (VOC's) using a pump to draw air through a Carbotrap Sampler. Volatile organic compounds (VOCs) present in the air are p...

  14. ARM Carbon Cycle Gases Flasks at SGP Site

    DOE Data Explorer

    Biraud, Sebastien

    2013-03-26

    Data from flasks are sampled at the Atmospheric Radiation Measurement Program ARM, Southern Great Plains Site and analyzed by the National Oceanic and Atmospheric Administration NOAA, Earth System Research Laboratory ESRL. The SGP site is included in the NOAA Cooperative Global Air Sampling Network. The surface samples are collected from a 60 m tower at the ARM SGP Central Facility, usually once per week in the afternoon. The aircraft samples are collected approximately weekly from a chartered aircraft, and the collection flight path is centered over the tower where the surface samples are collected. The samples are collected by the ARM and LBNL Carbon Project.

  15. Delta 13C in CO2 at Alert, NWT, Canada (June 1991 - December 2001)

    DOE Data Explorer

    Allison, C. E. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia; Francey, R. J. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia; Krummel, P. B. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia

    2003-04-01

    Measurements have been made on air collected in flasks at Alert, Canada, through the CSIRO GASLAB worldwide network. Flasks are filled with air at Alert and returned to the CSIRO GASLAB for analysis; typical sample storage times for flasks collected at Alert range from a few weeks to a few months. No significant effect on the stable carbon isotopic composition, δ13C, has been detected as a consequence of the sample storage time.

  16. Silver zeolite antimicrobial activity in aluminium heating, ventilation and air conditioning system ducts.

    PubMed

    Rizzetto, R; Mansi, A; Panatto, D; Rizzitelli, E; Tinteri, C; Sasso, T; Gasparini, R; Crovari, P

    2008-03-01

    Air pollution in confined environments is a serious health problem, in that most people spend long periods indoors (in homes, offices, classrooms etc.). Some people (children, the elderly, heart disease patients, asthmatic or allergic subjects) are at greater risk because of their conditions of frailty. The growing use of air-conditioning systems in many public and private buildings aggravates this health risk, especially when these systems are not correctly installed or regularly serviced. The aim of our study was to verify the capacity of Ag+ ions to stop the growth of bacteria and moulds inside the ducts of Heating, Ventilation and Air Conditioning system ducts (HVAC) systems when these ducts were lined with active Ag+ ions zeolite-coated panels. A Y-shaped HVAC model with two branches was used; one branch was made of traditional galvanized iron, as was the whole system, while the other was lined with active Ag+ zeolite-coated polyurethane panels. During the test, samples of dust present inside both ducts were collected and seeded in liquid and solid media to detect bacteria and moulds. The presence of bacteria was also sought in the air emerging from the outlets of both ducts. Tests made on samples of particulate collected from the two different ducts revealed a lower total bacterial load in the samples collected from the Ag+ zeolite-coated duct than in the samples from the traditional Zn galvanized duct. In addition, the values of bacterial load found in the air emerging from the Ag+ ions zeolite-lined duct were 5 times lower than those found in the air from the traditional galvanized iron duct. The utilization of Ag+ zeolite-coated panels in air-conditioning systems could improve the quality of the emerging air in comparison with traditional installations in galvanized iron. This innovation could prove particularly advantageous in the event of accidents during the installation of air-conditioning systems or of contaminated aerosols coming from outside.

  17. PIXE Analysis of Indoor Aerosols

    NASA Astrophysics Data System (ADS)

    Johnson, Christopher; Turley, Colin; Moore, Robert; Battaglia, Maria; Labrake, Scott; Vineyard, Michael

    2011-10-01

    We have performed a proton-induced X-ray emission (PIXE) analysis of aerosol samples collected in academic buildings at Union College to investigate the air quality in these buildings and the effectiveness of their air filtration systems. This is also the commissioning experiment for a new scattering chamber in the Union College Ion-Beam Analysis Laboratory. The aerosol samples were collected on Kapton foils using a nine-stage cascade impactor that separates particles according to their aerodynamic size. The foils were bombarded with beams of 2.2-MeV protons from the Union College 1.1-MV Pelletron Accelerator and the X-ray products were detected with an Amptek silicon drift detector. After subtracting the contribution from the Kapton foils, the X-ray energy spectra of the aerosol samples were analyzed using GUPIX software to determine the elemental concentrations of the samples. We will describe the collection of the aerosol samples, discuss the PIXE analysis, and present the results.

  18. US EPA Base Study Standard Operating Procedure for Sampling Volatile Organic Compounds in Indoor Air Using Evacuated Canisters

    EPA Pesticide Factsheets

    The objective of this procedure is to collect a representative sample of air containing volatile organic compound (VOC) contaminants present in an indoor environment using an evacuated canister, and to subsequently analyze the concentration of VOCs, as selected by EPA.

  19. Seasonal variation of water-soluble chemical components in the bulk atmospheric aerosols collected at Okinawa Island, Japan

    NASA Astrophysics Data System (ADS)

    Handa, D.; Nakajima, H.; Nakaema, F.; Arakaki, T.; Tanahara, A.

    2008-12-01

    The economic development and population growth in recent Asia spread air pollution. Emission rate of air pollutants from Asia, in particular oxides of nitrogen, surpassed those from North America and Europe and should continue to exceed them for decades. The study of the air pollution transported from Asian continent has gained a special attention in Japan. Okinawa Island is situated approximately 1500 km south of Tokyo, Japan, 2000 km southeast of Beijing, China, and 1000 km south of South Korea. Its location is ideal in observing East Asian atmospheric aerosols because maritime air mass prevails during summer, while continental air mass dominates during fall, winter, and spring. The maritime air mass data can be seen as background and can be compared with continental air masses which have been affected by anthropogenic activities. In 2005, Cape Hedo Atmosphere and Aerosol Monitoring Station (CHAAMS) was established by the National Institute for Environmental Studies (NIES) at the northern tip of Okinawa Island, Japan to monitor the air quality of Asia. Bulk aerosol samples were collected on quartz filters by using a high volume air sampler. Sampling duration was one week for each sample. We determined the concentrations of water-soluble anions, cations and dissolved organic carbon in the bulk aerosols collected at the CHAAMS, using ion chromatography, atomic absorption spectrometry, and total organic carbon analyzer, respectively. Seasonal variation of water-soluble chemical components showed that the concentrations were relatively low in summer, higher in fall and winter, and the highest in spring. When air mass came from Asian Continent, the concentrations of water-soluble chemical components were much higher compared to the other directions.

  20. Marine Technician's Handbook, Instructions for Taking Air Samples on Board Ship: Carbon Dioxide Project.

    ERIC Educational Resources Information Center

    Keeling, Charles D.

    This booklet is one of a series intended to provide explicit instructions for the collection of oceanographic data and samples at sea. The methods and procedures described have been used by the Scripps Institution of Oceanography and found reliable and up-to-date. Instructions are given for taking air samples on board ship to determine the…

  1. Design and validation of a wind tunnel system for odour sampling on liquid area sources.

    PubMed

    Capelli, L; Sironi, S; Del Rosso, R; Céntola, P

    2009-01-01

    The aim of this study is to describe the methods adopted for the design and the experimental validation of a wind tunnel, a sampling system suitable for the collection of gaseous samples on passive area sources, which allows to simulate wind action on the surface to be monitored. The first step of the work was the study of the air velocity profiles. The second step of the work consisted in the validation of the sampling system. For this purpose, the odour concentration of some air samples collected by means of the wind tunnel was measured by dynamic olfactometry. The results of the air velocity measurements show that the wind tunnel design features enabled the achievement of a uniform and homogeneous air flow through the hood. Moreover, the laboratory tests showed a very good correspondence between the odour concentration values measured at the wind tunnel outlet and the odour concentration values predicted by the application of a specific volatilization model, based on the Prandtl boundary layer theory. The agreement between experimental and theoretical trends demonstrate that the studied wind tunnel represents a suitable sampling system for the simulation of specific odour emission rates from liquid area sources without outward flow.

  2. Tank vapor characterization project. Headspace vapor characterization of Hanford waste tank 241-BY-108: Second comparison study results from samples collected on 3/28/96

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, B.L.; Pool, K.H.; Evans, J.C.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of waste storage tank 241-BY-108 (Tank BY-108) at the Hanford Site in Washington State. The results described in this report is the second in a series comparing vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling (ISVS) system without high efficiency particulate air (HEPA) prefiltration. The results include air concentrations of water (H{sub 2}O) and ammonia (NH{sub 3}), permanent gases, total non-methane organic compounds (TO-12), and individual organic analytes collected in SUMMA{trademark} canisters and on triple sorbent traps (TSTs).more » Samples were collected by Westinghouse Hanford Company (WHC) and analyzed by Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volume measurements provided by WHC.« less

  3. 77 FR 32632 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Three New Equivalent Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-01

    ... Hydrogen Peroxide Filter Extraction'' In this method, total suspended particulate matter (TSP) is collected on glass fiber filters according to 40 CFR Appendix G to part 50, EPA Reference Method for the Determination of Lead in Suspended Particulate Matter Collected From Ambient Air. The filter samples are...

  4. Applicability of the environmental relative moldiness index for quantification of residential mold contamination in an air pollution health effects study.

    PubMed

    Kamal, Ali; Burke, Janet; Vesper, Stephen; Batterman, Stuart; Vette, Alan; Godwin, Christopher; Chavez-Camarena, Marina; Norris, Gary

    2014-01-01

    The Near-Road Exposures and Effects of Urban Air Pollutants Study (NEXUS) investigated the impact of exposure to traffic-related air pollution on the respiratory health of asthmatic children in Detroit, Michigan. Since indoor mold exposure may also contribute to asthma, floor dust samples were collected in participants homes (n = 112) to assess mold contamination using the Environmental Relative Moldiness Index (ERMI). The repeatability of the ERMI over time, as well as ERMI differences between rooms and dust collection methods, was evaluated for insights into the application of the ERMI metric. ERMI values for the standard settled floor dust samples had a mean ± standard deviation of 14.5 ± 7.9, indicating high levels of mold contamination. ERMI values for samples collected from the same home 1 to 7 months apart (n = 52) were consistent and without systematic bias. ERMI values for separate bedroom and living room samples were highly correlated (r = 0.69, n = 66). Vacuum bag dust ERMI values were lower than for floor dust but correlated (r = 0.58, n = 28). These results support the use of the ERMI to evaluate residential mold exposure as a confounder in air pollution health effects studies.

  5. Microbial air quality in mass transport buses and work-related illness among bus drivers of Bangkok Mass Transit Authority.

    PubMed

    Luksamijarulkul, Pipat; Sundhiyodhin, Viboonsri; Luksamijarulkul, Soavalug; Kaewboonchoo, Orawan

    2004-06-01

    The air quality in mass transport buses, especially air-conditioned buses may affect bus drivers who work full time. Bus numbers 16, 63, 67 and 166 of the Seventh Bus Zone of Bangkok Mass Transit Authority were randomly selected to investigate for microbial air quality. Nine air-conditioned buses and 2-4 open-air buses for each number of the bus (36 air-conditioned buses and 12 open-air buses) were included. Five points of in-bus air samples in each studied bus were collected by using the Millipore A ir Tester Totally, 180 and 60 air samples collected from air-conditioned buses and open-air buses were cultured for bacterial and fungal counts. The bus drivers who drove the studied buses were interviewed towards histories of work-related illness while working. The results revealed that the mean +/- SD of bacterial counts in the studied open-air buses ranged from 358.50 +/- 146.66 CFU/m3 to 506 +/- 137.62 CFU/m3; bus number 16 had the highest level. As well as the mean +/- SD of fungal counts which ranged from 93.33 +/- 44.83 CFU/m3 to 302 +/- 294.65 CFU/m3; bus number 166 had the highest level. Whereas, the mean +/- SD of bacterial counts in the studied air-conditioned buses ranged from 115.24 +/- 136.01 CFU/m3 to 244.69 +/- 234.85 CFU/m3; bus numbers 16 and 67 had the highest level. As well as the mean +/- SD of fungal counts which rangedfrom 18.84 +/- 39.42 CFU/m3 to 96.13 +/- 234.76 CFU/m3; bus number 166 had the highest level. When 180 and 60 studied air samples were analyzed in detail, it was found that 33.33% of the air samples from open-air buses and 6.11% of air samples from air-conditioned buses had a high level of bacterial counts (> 500 CFU/m3) while 6.67% of air samples from open-air buses and 2.78% of air samples from air-conditioned buses had a high level of fungal counts (> 500 CFU/m3). Data from the history of work-related illnesses among the studied bus drivers showed that 91.67% of open-air bus drivers and 57.28% of air-conditioned bus drivers had symptoms of work-related illnesses, p = 0.0185.

  6. Investigation of a systematic offset in the measurement of organic carbon with a semicontinuous analyzer.

    PubMed

    Offenberg, John H; Lewandowski, Michael; Edney, Edward O; Kleindienst, Tadeusz E; Jaoui, Mohammed

    2007-05-01

    Organic carbon (OC) was measured semicontinuously in laboratory experiments of steady-state secondary organic aerosol formed by hydrocarbon + nitrogen oxide irradiations. Examination of the mass of carbon measured on the filter for various sample volumes reveals a systematic offset that is not observed when performing an instrumental blank. These findings suggest that simple subtraction of instrumental blanks determined as the standard analysis without sample collection (i.e., by cycling the pump and valves yet filtering zero liters of air followed by routine chemical analysis) from measured concentrations may be inadequate. This may be especially true for samples collected through the filtration of small air volumes wherein the influence of the systematic offset is greatest. All of the experiments show that filtering a larger volume of air minimizes the influence of contributions from the systematic offset. Application of these results to measurements of ambient concentrations of carbonaceous aerosol suggests a need for collection of sufficient carbon mass to minimize the relative influence of the offset signal.

  7. Contemporary-use pesticides in personal air samples during pregnancy and blood samples at delivery among urban minority mothers and newborns.

    PubMed Central

    Whyatt, Robin M; Barr, Dana B; Camann, David E; Kinney, Patrick L; Barr, John R; Andrews, Howard F; Hoepner, Lori A; Garfinkel, Robin; Hazi, Yair; Reyes, Andria; Ramirez, Judyth; Cosme, Yesenia; Perera, Frederica P

    2003-01-01

    We have measured 29 pesticides in plasma samples collected at birth between 1998 and 2001 from 230 mother and newborn pairs enrolled in the Columbia Center for Children's Environmental Health prospective cohort study. Our prior research has shown widespread pesticide use during pregnancy among this urban minority cohort from New York City. We also measured eight pesticides in 48-hr personal air samples collected from the mothers during pregnancy. The following seven pesticides were detected in 48-83% of plasma samples (range, 1-270 pg/g): the organophosphates chlorpyrifos and diazinon, the carbamates bendiocarb and 2-isopropoxyphenol (metabolite of propoxur), and the fungicides dicloran, phthalimide (metabolite of folpet and captan), and tetrahydrophthalimide (metabolite of captan and captafol). Maternal and cord plasma levels were similar and, except for phthalimide, were highly correlated (p < 0.001). Chlorpyrifos, diazinon, and propoxur were detected in 100% of personal air samples (range, 0.7-6,010 ng/m(3)). Diazinon and propoxur levels were significantly higher in the personal air of women reporting use of an exterminator, can sprays, and/or pest bombs during pregnancy compared with women reporting no pesticide use or use of lower toxicity methods only. A significant correlation was seen between personal air level of chlorpyrifos, diazinon, and propoxur and levels of these insecticides or their metabolites in plasma samples (maternal and/or cord, p < 0.05). The fungicide ortho-phenylphenol was also detected in 100% of air samples but was not measured in plasma. The remaining 22 pesticides were detected in 0-45% of air or plasma samples. Chlorpyrifos, diazinon, propoxur, and bendiocarb levels in air and/or plasma decreased significantly between 1998 and 2001. Findings indicate that pesticide exposures are frequent but decreasing and that the pesticides are readily transferred to the developing fetus during pregnancy. PMID:12727605

  8. Urinary and air phthalate concentrations and self-reported use of personal care products among minority pregnant women in New York city.

    PubMed

    Just, Allan C; Adibi, Jennifer J; Rundle, Andrew G; Calafat, Antonia M; Camann, David E; Hauser, Russ; Silva, Manori J; Whyatt, Robin M

    2010-11-01

    Diethyl phthalate (DEP) and di-n-butyl phthalate (DnBP) are used extensively in personal care products, including fragrances (DEP) and nail polish (DnBP). Between May 2003 and July 2006, we gathered questionnaire data on the use of seven product categories (deodorant, perfume, hair spray, hair gel, nail polish/polish remover, liquid soap/body wash, and lotion/mist) over 48 h during the third trimester of pregnancy from 186 inner-city women. A 48-h personal air sample was collected and analyzed for DEP and DnBP; a maternal spot urine sample was collected and analyzed for their monoester metabolites, monoethyl phthalate (MEP) and mono-n-butyl phthalate (MnBP), respectively. In all, 97% of air samples and 84% of urine samples were collected within ±2 days of the questionnaire. During the 48 h, 41% of women reported perfume use and 10% reported nail polish/polish remover use. In adjusted analyses, no association was seen between nail product use and air DnBP or urine MnBP concentrations. Women reporting perfume use had 2.3 times higher (95% CI 1.6, 3.3) urinary MEP concentrations. Personal air DEP increased by 7% for each 25% increase in a composite indicator of the six other product categories (P<0.05), but was not associated with perfume use. Air DEP was correlated with urine MEP concentrations only among non-perfume users (r=0.51, P<0.001). Results suggest that perfume use is a significant source of DEP exposure.

  9. Urinary and air phthalate concentrations and self-reported use of personal care products among minority pregnant women in New York City

    PubMed Central

    Just, Allan C.; Adibi, Jennifer J.; Rundle, Andrew G.; Calafat, Antonia M.; Camann, David E.; Hauser, Russ; Silva, Manori J.; Whyatt, Robin M.

    2011-01-01

    Diethyl phthalate (DEP) and di-n-butyl phthalate (DnBP) are used extensively in personal care products, including fragrances (DEP) and nail polish (DnBP). Between May 2003 and July 2006, we gathered questionnaire data on use of 7 product categories (deodorant, perfume, hair spray, hair gel, nail polish/polish remover, liquid soap/body wash, lotion/mist) over 48 hours during the 3rd trimester of pregnancy from 186 inner-city women. A 48-hour personal air sample was collected and analyzed for DEP and DnBP; a maternal spot urine sample was collected and analyzed for their monoester metabolites, monoethyl phthalate (MEP) and mono-n-butyl phthalate (MnBP), respectively. Ninety-seven percent of air samples and 84% of urine samples were collected within ±2 days of the questionnaire. During the 48 hours, 41% of women reported perfume use and 10% reported nail polish/polish remover use. In adjusted analyses, no association was seen between nail product use and air DnBP or urine MnBP concentrations. Women reporting perfume use had 2.3 times higher (95% CI 1.6, 3.3) urinary MEP concentrations. Personal air DEP increased 7% for each 25% increase in a composite indicator of the 6 other product categories (p<0.05) but was not associated with perfume use. Air DEP was correlated with urine MEP concentrations only among non-perfume users (r=0.51, p<0.001). Results suggest that perfume use is a significant source of DEP exposure. PMID:20354564

  10. Occupational exposures to styrene vapor in a manufacturing plant for fiber-reinforced composite wind turbine blades.

    PubMed

    Hammond, Duane; Garcia, Alberto; Feng, H Amy

    2011-07-01

    A utility-scale wind turbine blade manufacturing plant requested assistance from the National Institute for Occupational Safety and Health (NIOSH) in controlling worker exposures to styrene at a plant that produced 37 and 42 m long fiber-reinforced wind turbine blades. The plant requested NIOSH assistance because previous air sampling conducted by the company indicated concerns about peak styrene concentrations when workers entered the confined space inside of the wind turbine blade. NIOSH researchers conducted two site visits and collected personal breathing zone and area air samples while workers performed the wind turbine blade manufacturing tasks of vacuum-assisted resin transfer molding (VARTM), gelcoating, glue wiping, and installing the safety platform. All samples were collected during the course of normal employee work activities and analyzed for styrene using NIOSH Method 1501. All sampling was task based since full-shift sampling from a prior Occupational Safety and Health Administration (OSHA) compliance inspection did not show any exposures to styrene above the OSHA permissible exposure limit. During the initial NIOSH site visit, 67 personal breathing zone and 18 area air samples were collected while workers performed tasks of VARTM, gelcoating, glue wipe, and installation of a safety platform. After the initial site visit, the company made changes to the glue wipe task that eliminated the need for workers to enter the confined space inside of the wind turbine blade. During the follow-up site visit, 12 personal breathing zone and 8 area air samples were collected from workers performing the modified glue wipe task. During the initial site visit, the geometric means of the personal breathing zone styrene air samples were 1.8 p.p.m. (n = 21) for workers performing the VARTM task, 68 p.p.m. (n = 5) for workers installing a safety platform, and 340 p.p.m. (n = 14) for workers performing the glue wipe task, where n is the number of workers sampled for a given mean result. Gelcoating workers included job categories of millers, gelcoat machine operators, and gelcoaters. Geometric mean personal breathing zone styrene air samples were 150 p.p.m. (n = 6) for millers, 87 p.p.m. (n = 2) for the gelcoat machine operators, and 66 p.p.m. (n = 19) for gelcoaters. The geometric mean of the personal breathing zone styrene air samples from the glue wipe task measured during the follow-up site visit was 31 p.p.m. (n = 12). The closed molding VARTM process was very effective at controlling worker exposures to styrene. Personal breathing zone styrene air samples were reduced by an order of magnitude after changes were made to the glue wipe task. The company used chemical substitution to eliminate styrene exposure during the installation of the safety platform. Recommendations were provided to reduce styrene concentrations during gelcoating.

  11. Comparison of using polyurethane foam passive samplers and tree bark samples from Western China to determine atmospheric organochlorine pesticide.

    PubMed

    Li, Qiuxu; Lu, Yao; Jin, Jun; Li, Guangyao; Li, Peng; He, Chang; Wang, Ying

    2016-03-01

    Polyurethane foam (PUF) passive samplers were deployed and tree bark samples were collected at 15 sites across western China in 2013, and the organochlorine pesticide (OCP) concentrations in the samples were determined. Dichlorodiphenyltrichloroethane and its degradation products (collectively called DDTs), hexachlorocyclohexanes (HCHs), and hexachlorobenzene (HCB) were the dominant OCPs in the PUF samples and tree bark samples. The mean DDTs, HCHs and HCB concentrations were 33, 22 and 18ng/sample in the PUF samples, and 428, 74, and 43ng/(g lipid weight (lw)) in the tree bark, respectively. The OCP concentrations in the air, calculated using PUF-air and tree-bark-air partitioning models, were of the same order of magnitude. Both sample types showed that relatively fresh inputs of DDT and HCHs to the environment have occurred in western China. Meanwhile, PUF passive samplers were compared with the use of tree bark samples as passive samplers. The OCP compositions in the PUF and tree bark samples were different. Only the relatively stable OCPs (such as HCB, β-HCH and p,p'-dichlorodiphenyldichloro-ethylene (DDE)) were consistent in the PUF and tree bark samples. Copyright © 2015. Published by Elsevier B.V.

  12. Evaluation of sampling and analytical methods for nicotine and polynuclear aromatic hydrocarbon in indoor air. Final report, 1 February 1987-30 March 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chuang, J.C.; Kuhlman, M.R.; Hannan, S.W.

    1987-11-01

    The objective of this project was to evaluate a potential collection medium, XAD-4 resin, for collecting nicotine and polynuclear aromatic hydrocarbon (PAH) and to determine whether one collection system and one analytical method will allow quantification of both compound classes in air. The extraction efficiency study was to determine the extraction method to quantitatively remove nicotine and PAH from XAD-4 resin. The results showed that a two-step Soxhlet extraction consisting of dichloromethane followed by ethyl acetate resulted in the best recoveries for both nicotine and PAH. In the sampling efficiency study, XAD-2 and XAD-4 resin were compared, in parallel, formore » collection of PAH and nicotine. Quartz fiber filters were placed upstream of both adsorbents to collect particles. Prior to sampling, both XAD-2 and XAD-4 traps were spiked with known amounts (2 microgram) of perdeuterated PAH and D3-nicotine. The experiments were performed with cigarette smoking and nonsmoking conditions. The spiked PAH were retained well in both adsorbents after exposure to more than 300 cu. m. of indoor air. The spiked XAD-4 resin gave higher recoveries for D3-nicotine than did the spiked XAD-2 resin. The collection efficiency for PAH for both adsorbents is very similar but higher levels of nicotine were collected on XAD-4 resin.« less

  13. Determination of the isotopic composition of atmospheric methane and its application in the Antarctic

    NASA Technical Reports Server (NTRS)

    Lowe, David C.; Brenninkmeijer, Carl A. M.; Tyler, Stanley C.; Dlugkencky, Edward J.

    1991-01-01

    A procedure for establishing the C-13/C-12 ratio and the C-14 abundance in the atmospheric methane is discussed. The method involves air sample collection, measurement of the methane mixing ratio by gas chromotography followed by quantitative conversion of the methane in the air samples to CO2 and H2O, and analysis of the resulting CO2 for the C-13/C-12 ratio by stable isotope ratio mass spectrometry and measurement of C-14 content by accelerator mass spectrometry. The carbon isotropic composition of methane in air collected at Baring Head, New Zealand, and in air collected on aircraft flights between New Zealand and Antarctica is determined by the method, and no gradient in the composition between Baring Head and the South Pole station is found. As the technique is refined, and more data is gathered, small seasonal and long-term variations in C-13 are expected to be resolved.

  14. Organophosphates in aircraft cabin and cockpit air--method development and measurements of contaminants.

    PubMed

    Solbu, Kasper; Daae, Hanne Line; Olsen, Raymond; Thorud, Syvert; Ellingsen, Dag Gunnar; Lindgren, Torsten; Bakke, Berit; Lundanes, Elsa; Molander, Paal

    2011-05-01

    Methods for measurements and the potential for occupational exposure to organophosphates (OPs) originating from turbine and hydraulic oils among flying personnel in the aviation industry are described. Different sampling methods were applied, including active within-day methods for OPs and VOCs, newly developed passive long-term sample methods (deposition of OPs to wipe surface areas and to activated charcoal cloths), and measurements of OPs in high-efficiency particulate air (HEPA) recirculation filters (n = 6). In total, 95 and 72 within-day OP and VOC samples, respectively, have been collected during 47 flights in six different models of turbine jet engine, propeller and helicopter aircrafts (n = 40). In general, the OP air levels from the within-day samples were low. The most relevant OP in this regard originating from turbine and engine oils, tricresyl phosphate (TCP), was detected in only 4% of the samples (min-max

  15. Breakthrough during air sampling with polyurethane foam: What do PUF 2/PUF 1 ratios mean?

    PubMed

    Bidleman, Terry F; Tysklind, Mats

    2018-02-01

    Frontal chromatography theory is applied to describe movement of gaseous semivolatile organic compounds (SVOCs) through a column of polyurethane foam (PUF). Collected mass fractions (F C ) are predicted for sample volume/breakthrough volume ratios (τ = V S /V B ) up to 6.0 and PUF bed theoretical plate numbers (N) from 2 to 16. The predictions assume constant air concentrations and temperatures. Extension of the calculations is done to relate the collection efficiency of a 2-PUF train (F C1+2 ) to the PUF 2/PUF 1 ratio. F C1+2 exceeds 0.9 for PUF 2/PUF 1 ≤ 0.5 and lengths of PUF commonly used in air samplers. As the PUF 2/PUF 1 ratio approaches unity, confidence in these predictions is limited by the analytical ability to distinguish residues on the two PUFs. Field data should not be arbitrarily discarded because some analytes broke through to the backup PUF trap. The fractional collection efficiencies can be used to estimate air concentrations from quantities retained on the PUF trap when sampling is not quantitative. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. A simple novel device for air sampling by electrokinetic capture

    DOE PAGES

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; ...

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.« less

  17. A simple novel device for air sampling by electrokinetic capture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.« less

  18. A simple novel device for air sampling by electrokinetic capture.

    PubMed

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87 %, with the reference filter taken as "gold standard." Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. The performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.

  19. Evaluating fungal populations by genera/species on wide body commercial passenger aircraft and in airport terminals.

    PubMed

    McKernan, Lauralynn Taylor; Burge, Harriet; Wallingford, Kenneth M; Hein, Misty J; Herrick, Robert

    2007-04-01

    Given the potential health effects of fungi and the amount of time aircrew and passengers spend inside aircraft, it is important to study fungal populations in the aircraft environment. Research objectives included documenting the genera/species of airborne culturable fungal concentrations and total spore concentrations on a twin-aisle wide body commercial passenger aircraft. Twelve flights between 4.5 and 6.5 h in duration on Boeing 767 (B-767) aircraft were evaluated. Two air cooling packs and 50% recirculation rate (i.e. 50:50 mix of outside air and filtered inside air) were utilized during flight operations. Passenger occupancy rates varied from 67 to 100%. N-6 impactors and total spore traps were used to collect sequential, triplicate air samples in the front and rear of coach class during six sampling intervals throughout each flight: boarding, mid-climb, early cruise, mid-cruise, late cruise and deplaning. Comparison air samples were also collected inside and outside the airport terminals at the origin and destination cities resulting in a total of 522 culturable and 517 total spore samples. A total of 45 surface wipe samples were collected using swabs onboard the aircraft and inside the airport terminals. A variety of taxa were observed in the culturable and total spore samples. A frequency analysis of the fungal data indicated that Cladosporium, Aspergillus and Penicillium were predominant genera in the culturable samples whereas Cladosporium, Basidiospores and Penicillium/Aspergillus were predominant in the total spore samples. Fungal populations observed inside the aircraft were comprised of similar genera, detected significantly less frequently and with lower mean concentrations than those observed in typical office buildings. Although sources internal to the aircraft could not be ruled out, our data demonstrate the importance of passenger activity as the source of the fungi observed on aircraft. Isolated fungal peak events occurred occasionally when concentrations of a particular genus or species rose sharply inside the cabin for a limited period. Overall, our research demonstrates that on the sampled flights the B-767 filtration system operated efficiently to remove fungal spores when two air cooling packs and 50% recirculation rate were utilized during flight operations.

  20. RELATIVE CONGENER SCALING OF POLYCHLORINATED DIBENZO-P-DIOXINS AND DIBENZOFURANS TO ESTIMATE BUILDING FIRE CONTRIBUTIONS IN AIR, SURFACE WIPES, AND DUST SAMPLES

    EPA Science Inventory

    EPA collected ambient air samples in lower Manhattan for about nine months following the September 11, 2001 (9/11) World Trade Center (WTC) attacks. Measurements were made of a host of airborne contaminants including volatile organic compounds (VOCs), polycyclic aromatic hydroca...

  1. Transport of NMHCs and halocarbons observed by CARIBIC: A case study

    NASA Astrophysics Data System (ADS)

    Baker, A. K.; Brenninkmeijer, C. A. M.; Oram, D. E.; O'Sullivan, D. A.; Schuck, T. J.; Slemr, F.

    2009-04-01

    The CARIBIC project (Civil Aircraft for the Regular Investigation of the Atmosphere Based on an Instrument Container) involves the monthly deployment of an instrument container equipped to make atmospheric measurements from onboard a long-range commercial airliner. Since December 2004, flights for the second phase of CARIBIC have been aboard a Lufthansa Airbus A340-600 traveling between Frankfurt, Germany and destinations in Asia, North America and South America. The instrument package housed in the container is fully automated and during each flight carries out a variety of real-time trace gas and aerosol measurements, and also collects 28 air samples, which are analyzed upon return to the laboratory. Routine measurements made from the sampling flasks include greenhouse gases, nonmethane hydrocarbons (NMHCs), and halocarbons; results of air sample analysis form the basis for the data discussed here. While the majority of CARIBIC samples represent background free tropospheric air and air representative of the upper troposphere/lower stratosphere, the aircraft also, less frequently, encounters air parcels influenced by more recent emissions. Here we present a case study of a round-trip flight between Frankfurt and Toronto, Canada during September 2007. During this flight, different air masses of unique origin were encountered; a number of samples were influenced by transport from the Gulf of Mexico, while others had source regions in Central and Southeast Asia. Samples from the Gulf of Mexico exhibited enhancements in C3-C6 alkanes, as well as a number of halogenated compounds with oceanic sources, such as methyl iodide and bromoform, while Asian samples had enhanced levels of combustion products (CO, acetylene, benzene) and anthropogenic halocarbons (methlyene chloride, chloroform, perchloroethylene). Additionally, a number of samples also showed stratospheric influence, and these samples were characterized by relatively depleted levels of many of the compounds measured. Characterization of the different air masses will be discussed, and these results will be compared to samples collected during other CARIBIC flights, which are representative of both background air and air masses influenced by similar source regions.

  2. Evaluation of portable air samplers for monitoring airborne culturable bacteria

    NASA Technical Reports Server (NTRS)

    Mehta, S. K.; Bell-Robinson, D. M.; Groves, T. O.; Stetzenbach, L. D.; Pierson, D. L.

    2000-01-01

    Airborne culturable bacteria were monitored at five locations (three in an office/laboratory building and two in a private residence) in a series of experiments designed to compare the efficiency of four air samplers: the Andersen two-stage, Burkard portable, RCS Plus, and SAS Super 90 samplers. A total of 280 samples was collected. The four samplers were operated simultaneously, each sampling 100 L of air with collection on trypticase soy agar. The data were corrected by applying positive hole conversion factors for the Burkard portable, Andersen two-stage, and SAS Super 90 air samplers, and were expressed as log10 values prior to statistical analysis by analysis of variance. The Burkard portable air sampler retrieved the highest number of airborne culturable bacteria at four of the five sampling sites, followed by the SAS Super 90 and the Andersen two-stage impactor. The number of bacteria retrieved by the RCS Plus was significantly less than those retrieved by the other samplers. Among the predominant bacterial genera retrieved by all samplers were Staphylococcus, Bacillus, Corynebacterium, Micrococcus, and Streptococcus.

  3. Air Pollution Source/receptor Relationships in South Coast Air Basin, CA

    NASA Astrophysics Data System (ADS)

    Gao, Ning

    This research project includes the application of some existing receptor models to study the air pollution source/receptor relationships in the South Coast Air Basin (SoCAB) of southern California, the development of a new receptor model and the testing and the modifications of some existing models. These existing receptor models used include principal component factor analysis (PCA), potential source contribution function (PSCF) analysis, Kohonen's neural network combined with Prim's minimal spanning tree (TREE-MAP), and direct trilinear decomposition followed by a matrix reconstruction. The ambient concentration measurements used in this study are a subset of the data collected during the 1987 field exercise of Southern California Air Quality Study (SCAQS). It consists of a number of gaseous and particulate pollutants analyzed from samples collected by SCAQS samplers at eight sampling sites, Anaheim, Azusa, Burbank, Claremont, Downtown Los Angeles, Hawthorne, Long Beach, and Rubidoux. Based on the information of emission inventories, meteorology and ambient concentrations, this receptor modeling study has revealed mechanisms that influence the air quality in SoCAB. Some of the mechanisms affecting the air quality in SoCAB that were revealed during this study include the following aspects. The SO_2 collected at sampling sites is mainly contributed by refineries in the coastal area and the ships equipped with oil-fired boilers off shore. Combustion of fossil fuel by automobiles dominates the emission of NO_{rm x} that is subsequently transformed and collected at sampling sites. Electric power plants also contribute HNO_3 to the sampling sites. A large feedlot in the eastern region of SoCAB has been identified as the major source of NH_3. Possible contributions from other industrial sources such as smelters and incinerators were also revealed. The results of this study also suggest the possibility of DMS (dimethylsulfide) and NH_3 emissions from off-shore sediments that have been contaminated by waste sludge disposal. The study also discovered that non-anthropogenic sources account for the observation of many chemical components being brought to the sampling sites, such as seasalt particles, soil particles, and Cl emission from Mojave Desert. The potential and limitation of the receptor models have been evaluated and some modifications have been made to improve the value of the models. A source apportionment method has been developed based on the application results of the potential source contribution function (PSCF) analysis.

  4. Mayenite Synthesized Using the Citrate Sol-Gel Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ude, Sabina N; Rawn, Claudia J; Meisner, Roberta A

    2014-01-01

    A citrate sol-gel method has been used to synthesize mayenite (Ca12Al14O33). X-ray powder diffraction data show that the samples synthesized using the citrate sol-gel method contained CaAl2O4 and CaCO3 along with mayenite when fired ex-situ in air at 800 C but were single phase when fired at 900 C and above. Using high temperature x-ray diffraction, data collected in-situ in air at temperatures of 600 C and below showed only amorphous content; however, data collected at higher temperatures indicated the first phase to crystallize is CaCO3. High temperature x-ray diffraction data collected in 4% H2/96% N2 does not show themore » presence of CaCO3, and Ca12Al14O33 starts to form around 850 C. In comparison, x-ray powder diffraction data collected ex-situ on samples synthesized using traditional solid-state synthesis shows that single phase was not reached until samples were fired at 1350 C. DTA/TGA data collected either in a nitrogen environment or air on samples synthesized using the citrate gel method suggest the complete decomposition of metastable phases and the formation of mayenite at 900 C, although the phase evolution is very different depending on the environment. Brunauer-Emmett-Teller (BET) measurements showed a slightly higher surface area of 7.4 0.1 m2/g in the citrate gel synthesized samples compared to solid-state synthesized sample with a surface area of 1.61 0.02 m2/g. SEM images show a larger particle size for samples synthesized using the solid-state method compared to those synthesized using the citrate gel method.« less

  5. Biomonitoring polycyclic aromatic hydrocarbons by Salix matsudana leaves: A comparison with the relevant air content and evaluation of environmental parameter effects

    NASA Astrophysics Data System (ADS)

    Zhao, Xiangai; He, Miao; Shang, Haibo; Yu, Hongling; Wang, Hao; Li, Huijie; Piao, Jingyi; Quinto, Maurizio; Li, Donghao

    2018-05-01

    Studies on seasonal distribution characteristics of polycyclic aromatic hydrocarbons (PAHs) in Salix matsudana leaves covering its annual life cycle were carried out in order to evaluate plant leaf response sensitivity to air pollution. Salix matsudana leaves were collected throughout different development phases of plant leaf inclusive of bud break to fallen leaves, covering from spring (May) to autumn (November). Simultaneously, particle and gas samples were collected using a high volume air sampler. Seven different PAHs were determined simultaneously in these samples. The temperature dependence of the partitioning of PAHs in air and plant leaves was investigated and the results were incorporated into a mathematical model. The measured plant/air partition coefficients have been found to be exponentially proportional to the reciprocal temperature, in agreement with theoretical expectations. Furthermore, in order to define the influence of different parameters on PAH adsorption on plant leaves, area and lipid leaf content were also measured. Results demonstrated that temperature plays a very important role in PAHs partitioning and that this value should be carefully considered during sampling, in order to obtain the best correlation between PAHs concentration in air and leaves.

  6. Atmospheric CO2 Records from Sites in the Scripps Institution of Oceanography (SIO) Air Sampling Network (1985 - 2007)

    DOE Data Explorer

    Keeling, R. F. [Scripps Institution of Oceanography (SIO) University of California, La Jolla, California (USA); Piper, S. C. [Scripps Institution of Oceanography (SIO) University of California, La Jolla, California (USA); Bollenbacher, A. F. [Scripps Institution of Oceanography (SIO) University of California, La Jolla, California (USA); Walker , J. S. [Scripps Institution of Oceanography (SIO) University of California, La Jolla, California (USA)

    2008-05-01

    At Alert weekly air samples are collected in 5-L evacuated glass flasks exposed in triplicate. Flasks are returned to the SIO for CO2 determinations, which are made using an Applied Physics Corporation nondispersive infrared gas analyzer. In May 1983, the CO2-in-N2 calibration gases were replaced with CO2-in-air calibration gases, which are currently used (Keeling et al. 2002). Data are in terms of the Scripps "03A" calibration scale. On the basis of flask samples collected at Alert and analyzed by SIO, the annual average of the fitted monthly concentrations CO2 rose from 348.48 ppmv in 1986 to 384.84 ppmv in 2007. This represents an average annual growth rate of 1.73 ppmv per year at Alert.

  7. Measurement of the odor impact of a waste deposit using the SF6-tracer method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roetzer, H.; Muehldorf, V.; Riesing, J.

    1994-12-01

    Landfill gas emitted from a waste disposal often causes odor nuisance in the vicinity. To verify that the odor concentrations were below these limit values, the odor contributions of different sources had to be distinguished. A tracer method was applied to measure the odor impact of the sanitary landfill to its environment. The emitted landfill gas was labelled with the tracer gas SF6. The tracer gas was parted to even amounts and released through ten special nozzles equally distributed over the surface of the landfill. In the area around the landfill the concentration of the tracer gas was measured bymore » collecting air samples and analyzing them with a gas chromatograph with an electron capture detector. Fifteen air sampling units were used to collect eight consecutive air samples at each selected point. These measurements gave the relation between the emission of landfill gas and the resulting concentrations in ambient air.« less

  8. ARM-LBNL-NOAA Flask Sampler for Carbon Cycle Gases

    DOE Data Explorer

    Torn, Margaret

    2008-01-15

    Data from ccg-flasks are sampled at the ARM SGP site and analyzed by the NOAA Earth System Research Laboratory (ESRL) as part of the NOAA Cooperative Global Air Sampling Network. Surface samples are collected from a 60m tower at the SGP Central Facility, usually once per week on one afternoon. The aircraft samples are collected approximately weekly from a chartered aircraft, and the collection flight path is centered over the tower where the surface samples are collected. Samples are collected by the ARM/LBNL Carbon Project. CO2 flask data contains measurements of CO2 concentration and CO2 stable isotope ratios (13CO2 and C18OO) from flasks collected at the SGP site. The flask samples are collected at 2m, 4m, 25m, and 60m along the 60m tower.

  9. Water Collection from Air Humidity in Bahrain

    NASA Astrophysics Data System (ADS)

    Dahman, Nidal A.; Al Juboori, Khalil J.; BuKamal, Eman A.; Ali, Fatima M.; AlSharooqi, Khadija K.; Al-Banna, Shaima A.

    2017-11-01

    The Kingdom of Bahrain falls geographically in one of the driest regions in the world. Conventional fresh surface water bodies, such as rivers and lakes, are nonexistent and for water consumption, Bahrain prominently relies on the desalination of sea water. This paper presents an ongoing project that is being pursued by a group of student and their advising professors to investigate the viability of extracting water from air humidity. Dehumidifiers have been utilized as water extraction devices. Those devices have been distributed on six areas that were selected based on a rigorous geospatial modeling of historical meteorological data. The areas fall in residential and industrial neighborhoods that are located in the main island and the island of Muharraq. Water samples have been collected three times every week since May of 2016 and the collection process will continue until May of 2017. The collected water samples have been analyzed against numerous variables individually and in combinations including: amount of water collected per hour versus geographical location, amount of water collected per hour versus meteorological factors, suitability of collected water for potable human consumption, detection of air pollution in the areas of collection and the economy of this method of water collection in comparison to other nonconventional methods. An overview of the completed analysis results is presented in this paper.

  10. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    PubMed

    Mullins, Garrett R; Bruns, David E

    2017-10-01

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (p<0.01), LD (p<0.01), and potassium (p<0.02) in plasma. Removing air space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (p<0.02 vs conventionally filled collection tube). Clotted blood developed less foaming during PTS transport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (p<0.03) in serum than in plasma after PTS sample transport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Occurrence of Thermotolerant Campylobacter in Raw Poultry Meat, Environmental and Pigeon Stools Collected in Open-Air Markets.

    PubMed

    Bellio, Alberto; Traversa, Amaranta; Adriano, Daniela; Bianchi, Daniela Manila; Colzani, Alberto; Gili, Stefano; Dondo, Alessandro; Gallina, Silvia; Grattarola, Carla; Maurella, Cristiana; Zoppi, Simona; Zuccon, Fabio; Decastelli, Lucia

    2014-08-28

    Campylobacteriosis was the most commonly reported zoonosis for confirmed human cases in European Union during 2011. Poultry meat was very often implicated in Campylobacter infections in humans. In Italy commerce of raw poultry meat is common in open-air markets: these areas can be considered at high risk of bacterial contamination due to the high presence birds like pigeons. The aim of this study was to collect data about the contamination by thermotolerant Campylobacter of raw poultry meat commercialised in open-air markets, of work-surfaces in contact with poultry meat and of pigeon stools sampled in the market areas in Turin, Northern Italy. Between September 2011 and December 2012, 86 raw poultry meat samples, 86 environmental swabs and 108 animal samples were collected in 38 open-air markets. Analysis were carried out according to ISO10272-1:2006 standard. C.coli was detected in 2.3% (2/86) of raw poultry meat samples, whereas no swab (0/86) resulted positive. Of pigeon stool 28% (30/107) was positive for C.jejuni (83.3% C.jejuni subsp . jejuni and 16.7% C.jejuni subsp . doylei ). C.jejuni subsp. jejuni was isolated from 1 dead pigeon . Our results showed lower rates of contamination than those reported at retail in Europe. Although samples were collected in areas at high risk of contamination, raw poultry meat and work surfaces reported a low level of presence of thermotolerant Campylobacter . The high percentage of C.jejuni isolated from pigeon stools showed the importance of a continuous application of preventive measures by the food business operators and the surveillance activity by the Competent Authority.

  12. Dynamics of airborne fungal populations in a large office building

    NASA Technical Reports Server (NTRS)

    Burge, H. A.; Pierson, D. L.; Groves, T. O.; Strawn, K. F.; Mishra, S. K.

    2000-01-01

    The increasing concern with bioaerosols in large office buildings prompted this prospective study of airborne fungal concentrations in a newly constructed building on the Gulf coast. We collected volumetric culture plate air samples on 14 occasions over the 18-month period immediately following building occupancy. On each sampling occasion, we collected duplicate samples from three sites on three floors of this six-story building, and an outdoor sample. Fungal concentrations indoors were consistently below those outdoors, and no sample clearly indicated fungal contamination in the building, although visible growth appeared in the ventilation system during the course of the study. We conclude that modern mechanically ventilated buildings prevent the intrusion of most of the outdoor fungal aerosol, and that even relatively extensive air sampling protocols may not sufficiently document the microbial status of buildings.

  13. Sampling and detection of Legionella pneumophila aerosols generated from an industrial cooling tower.

    PubMed

    Ishimatsu, S; Miyamoto, H; Hori, H; Tanaka, I; Yoshida, S

    2001-08-01

    Cooling tower water has frequently been cited as a source of infection in outbreaks of Legionnaires' disease. However, there have been few reports on the presence of legionellae in aerosols from cooling towers. This paper describes our use of an impinger or a six-stage microbial impactor for detecting legionellae in air around a cooling tower contaminated with L. pneumophila (1.2+/-0.3x10(5) CFU/100 ml). Phosphate-buffered saline, Page's saline, 2% yeast extract solution and buffered yeast extract (BYE) broth were tested to evaluate their collection efficiency. These solutions were compared in laboratory experiments using an aerosol of L. pneumophila serogroup (SG) 1. Because BYE broth was the most efficient and storable collecting fluid among them, it was used for outdoor air sampling. In the outdoor air sampling, aerosolized L. pneumophila SG 6 was detected in the air around the cooling tower by the impinger (0.09 CFU/l. air). No legionellae were detected by the impactor with Legionella-selective agar plates (WYOalpha) because the plates were overgrown with fungi. Repetitive element PCR (rep-PCR) and arbitrarily primed PCR (AP-PCR) were employed to assess the epidemiological relationship among Legionella isolates from the air sample and the cooling tower water samples. L. pneumophila SG 6 isolated from the aerosols produced rep-PCR and AP-PCR fingerprints identical to those of L. pneumophila SG 6 strains from the cooling tower water, suggesting that the bacterium was aerosolized from the cooling tower.

  14. Patterns of streamwater acidity in Lye Brook Wilderness, Vermont, USA

    Treesearch

    John L. Campbell; Christopher Eagar; William H. McDowell

    2002-01-01

    Under the United States Clean Air Act Amendments of 1977, a class I designation safeguards wilderness areas from the negative effects of new sources of air pollution. We monitored streamwater chemistry in the class I Lye Brook Wilderness in southwestern Vermont from May 1994 through August 1995. Stream samples were collected biweekly at nine sampling locations...

  15. Comparison of storage stability of odorous VOCs in polyester aluminum and polyvinyl fluoride tedlar bags

    USDA-ARS?s Scientific Manuscript database

    Whole air sampling using containers such as flexible bags or rigid canisters is commonly used to collect samples of volatile organic compounds (VOC) in air. The objective of this study was to compare the stability of polyester aluminum (PEA) and polyvinyl fluoride (PVF, brand name Tedlar®) bags for ...

  16. Odor and odorous chemical emissions from dairy and swine facilities: Part 5-Simultaneous chemical and sensory analysis with Gas Chromatography - Mass Spectrometry - Olfactometry

    USDA-ARS?s Scientific Manuscript database

    Simultaneous chemical and sensory analyses using gas chromatography-mass spectrometry-olfactometry (GC-MS-O) for air samples collected at barn exhaust fans were used for quantification and ranking of odor impact of target odorous gases. Fifteen target odorous VOCs (odorants) were selected. Air sampl...

  17. Early detection of foot-and-mouth disease virus from infected cattle using a dry filter air sampling system

    USDA-ARS?s Scientific Manuscript database

    Foot-and-mouth disease (FMD) is a highly contagious livestock disease of high economic impact. Early detection of FMD virus (FMDV) is fundamental for rapid outbreak control. Air sampling collection has been demonstrated as a useful technique for detection of FMDV RNA in infected animals, related to ...

  18. Environmental stress in the Gulf of Mexico and its potential impact on public health

    PubMed Central

    Turner, J.; Walter, L.; Lathan, N.; Thorpe, D.; Ogbevoen, P.; Daye, J.; Alcorn, D.; Wilson, S.; Semien, J.; Richard, T.; Johnson, T.; McCabe, K.; Estrada, J.J.; Galvez, F.; Velasco, C.; Reiss, K.

    2017-01-01

    The Deepwater Horizon (DWH) oil spill in the Gulf of Mexico was the largest maritime oil spill in history resulting in the accumulation of genotoxic substances in the air, soil, and water. This has potential far-reaching health impacts on cleanup field workers and on the populations living in the contaminated coastal areas. We have employed portable airborne particulate matter samplers (SKC Biosampler Impinger) and a genetically engineered bacterial reporter system (umu-ChromoTest from EBPI) to determine levels of genotoxicity of air samples collected from highly contaminated areas of coastal Louisiana including Grand Isle, Port Fourchon, and Elmer's Island in the spring, summer and fall of 2011, 2012, 2013 and 2014. Air samples collected from a non-contaminated area, Sea Rim State Park, Texas, served as a control for background airborne genotoxic particles. In comparison to controls, air samples from the contaminated areas demonstrated highly significant increases in genotoxicity with the highest values registered during the month of July in 2011, 2013, and 2014, in all three locations. This seasonal trend was disrupted in 2012, when the highest genotoxicity values were detected in October, which correlated with hurricane Isaac landfall in late August of 2012, about five weeks before a routine collection of fall air samples. Our data demonstrate: (i) high levels of air genotoxicity in the monitored areas over last four years post DWH oil spill; (ii) airborne particulate genotoxicity peaks in summers and correlates with high temperatures and high humidity; and (iii) this seasonal trend was disrupted by the hurricane Isaac landfall, which further supports the concept of a continuous negative impact of the oil spill in this region. PMID:26745734

  19. Environmental stress in the Gulf of Mexico and its potential impact on public health.

    PubMed

    Singleton, B; Turner, J; Walter, L; Lathan, N; Thorpe, D; Ogbevoen, P; Daye, J; Alcorn, D; Wilson, S; Semien, J; Richard, T; Johnson, T; McCabe, K; Estrada, J J; Galvez, F; Velasco, C; Reiss, K

    2016-04-01

    The Deepwater Horizon (DWH) oil spill in the Gulf of Mexico was the largest maritime oil spill in history resulting in the accumulation of genotoxic substances in the air, soil, and water. This has potential far-reaching health impacts on cleanup field workers and on the populations living in the contaminated coastal areas. We have employed portable airborne particulate matter samplers (SKC Biosampler Impinger) and a genetically engineered bacterial reporter system (umu-ChromoTest from EBPI) to determine levels of genotoxicity of air samples collected from highly contaminated areas of coastal Louisiana including Grand Isle, Port Fourchon, and Elmer's Island in the spring, summer and fall of 2011, 2012, 2013 and 2014. Air samples collected from a non-contaminated area, Sea Rim State Park, Texas, served as a control for background airborne genotoxic particles. In comparison to controls, air samples from the contaminated areas demonstrated highly significant increases in genotoxicity with the highest values registered during the month of July in 2011, 2013, and 2014, in all three locations. This seasonal trend was disrupted in 2012, when the highest genotoxicity values were detected in October, which correlated with hurricane Isaac landfall in late August of 2012, about five weeks before a routine collection of fall air samples. Our data demonstrate: (i) high levels of air genotoxicity in the monitored areas over last four years post DWH oil spill; (ii) airborne particulate genotoxicity peaks in summers and correlates with high temperatures and high humidity; and (iii) this seasonal trend was disrupted by the hurricane Isaac landfall, which further supports the concept of a continuous negative impact of the oil spill in this region. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Water- and air-quality monitoring of the Sweetwater Reservoir Watershed, San Diego County, California-Phase One results, continued, 1999-2001

    USGS Publications Warehouse

    Mendez, Gregory O.; Foreman, William T.; Sidhu, Jagdeep S.; Majewski, Michael S.

    2007-01-01

    In 1998, the U.S. Geological Survey, in cooperation with the Sweetwater Authority, began a study to assess the overall health of the Sweetwater watershed with respect to chemical contamination. The study included regular sampling of air and water at Sweetwater Reservoir for chemical contaminants, including volatile organic compounds, polycyclic aromatic hydrocarbons, pesticides, and major and trace elements. Background water samples were collected at Loveland Reservoir for volatile organic compounds and pesticides. The purpose of this study was to monitor changes in contaminant composition and concentration in the air and water resulting from the construction and operation of State Route 125 near Sweetwater Reservoir. To accomplish this, the study was divided into two phases. Phase One sampling was designed to establish baseline conditions for target compounds in terms of detection frequency and concentration in air and water. Phase Two sampling is planned to continue at the established monitoring sites during and after construction of State Route 125 to assess the chemical impact this roadway alignment project may have on the water quality in the reservoir. In addition to the ongoing data collection, several special studies were initiated to assess the occurrence of specific chemicals of concern, such as low-use pesticides, trace metals, and wastewater compounds. This report describes the study design, and the sampling and analytical methods, and presents the results for the second and third years of the study (October 1999 to September 2001). Data collected during the first year of sampling (October 1998 to September 1999) were published in 2002.

  1. RECOMMENDED OPERATING PROCEDURE NO. 56: COLLECTION OF GASEOUS GRAB SAMPLES FROM COMBUSTION SOURCES FOR NITROUS OXIDE MEASUREMENT

    EPA Science Inventory

    The document is a recommended operating procedure, prepare or use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent a...

  2. Monte Carlo simulation of air sampling methods for the measurement of radon decay products.

    PubMed

    Sima, Octavian; Luca, Aurelian; Sahagia, Maria

    2017-08-01

    A stochastic model of the processes involved in the measurement of the activity of the 222 Rn decay products was developed. The distributions of the relevant factors, including air sampling and radionuclide collection, are propagated using Monte Carlo simulation to the final distribution of the measurement results. The uncertainties of the 222 Rn decay products concentrations in the air are realistically evaluated. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Toxicological Assessment of ISS Air Quality: Contingency Sampling - February 2013

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie

    2013-01-01

    Two grab sample containers (GSCs) were collected by crew members onboard ISS in response to a vinegar-like odor in the US Lab. On February 5, the first sample was collected approximately 1 hour after the odor was noted by the crew in the forward portion of the Lab. The second sample was collected on February 22 when a similar odor was noted and localized to the end ports of the microgravity science glovebox (MSG). The crewmember removed a glove from the MSG and collected the GSC inside the glovebox volume. Both samples were returned on SpaceX-2 for ground analysis.

  4. Exposures to volatile organic compounds (VOCs) and associated health risks of socio-economically disadvantaged population in a "hot spot" in Camden, New Jersey

    NASA Astrophysics Data System (ADS)

    Wu, Xiangmei (May); Fan, Zhihua (Tina); Zhu, Xianlei; Jung, Kyung Hwa; Ohman-Strickland, Pamela; Weisel, Clifford P.; Lioy, Paul J.

    2012-09-01

    To address disparities in health risks associated with ambient air pollution for racial/ethnic minority groups, this study characterized personal and ambient concentrations of volatile organic compounds (VOCs) in a suspected hot spot of air pollution - the Village of Waterfront South (WFS), and an urban reference community - the Copewood/Davis Streets (CDS) neighborhood in Camden, New Jersey. Both are minority-dominant, impoverished communities. We collected 24-h integrated personal air samples from 54 WFS residents and 53 CDS residents, with one sample on a weekday and one on a weekend day during the summer and winter seasons of 2004-2006. Ambient air samples from the center of each community were also collected simultaneously during personal air sampling. Toluene, ethylbenzene, and xylenes (TEX) presented higher (p < 0.05) ambient levels in WFS than in CDS, particularly during weekdays. A stronger association between personal and ambient concentrations of MTBE and TEX was found in WFS than in CDS. Fourteen to forty-two percent of the variation in personal MTBE, hexane, benzene, and TEX was explained by local outdoor air pollution. These observations indicated that local sources impacted the community air pollution and personal exposure in WFS. The estimated cancer risks resulting from two locally emitted VOCs, benzene and ethylbenzene, and non-cancer neurological and respiratory effects resulting from hexane, benzene, toluene, and xylenes exceeded the US EPA risk benchmarks in both communities. These findings emphasized the need to address disparity in health risks associated with ambient air pollution for the socio-economically disadvantaged groups. This study also demonstrated that air pollution hot spots similar to WFS can provide robust setting to investigate health effects of ambient air pollution.

  5. Colorimetric-Solid Phase Extraction Technology for Water Quality Monitoring: Evaluation of C-SPE and Debubbling Methods in Microgravity

    NASA Technical Reports Server (NTRS)

    Hazen-Bosveld, April; Lipert, Robert J.; Nordling, John; Shih, Chien-Ju; Siperko, Lorraine; Porter, Marc D.; Gazda, Daniel B.; Rutz, Jeff A.; Straub, John E.; Schultz, John R.; hide

    2007-01-01

    Colorimetric-solid phase extraction (C-SPE) is being developed as a method for in-flight monitoring of spacecraft water quality. C-SPE is based on measuring the change in the diffuse reflectance spectrum of indicator disks following exposure to a water sample. Previous microgravity testing has shown that air bubbles suspended in water samples can cause uncertainty in the volume of liquid passed through the disks, leading to errors in the determination of water quality parameter concentrations. We report here the results of a recent series of C-9 microgravity experiments designed to evaluate manual manipulation as a means to collect bubble-free water samples of specified volumes from water sample bags containing up to 47% air. The effectiveness of manual manipulation was verified by comparing the results from C-SPE analyses of silver(I) and iodine performed in-flight using samples collected and debubbled in microgravity to those performed on-ground using bubble-free samples. The ground and flight results showed excellent agreement, demonstrating that manual manipulation is an effective means for collecting bubble-free water samples in microgravity.

  6. Atmospheric CO2 Records from Sites in the Main Geophysical Observatory Air Sampling Network (1983 - 1993)

    DOE Data Explorer

    Brounshtein, A. M. [Main Geophysical Observatory, St. Petersburg, Russia; Shaskov, A. A. [Main Geophysical Observatory, St. Petersburg, Russia; Paramonova, N. N. [Main Geophysical Observatory, St. Petersburg, Russia; Privalov, V. I. [Main Geophysical Observatory, St. Petersburg, Russia; Starodubtsev, Y. A. [Main Geophysical Observatory, St. Petersburg, Russia

    1997-01-01

    Air samples were collected from five sites in the Main Geophysical Observatory air sampling network to monitor the atmospheric CO2 from 1983 - 1993. Airwas collected generally four times per month in pairs of 1.5-L stainless steel electropolished flasks with one greaseless stainless steel stopcock. Sampling was performed by opening the stopcock of the flasks, which have been evacuated at the central laboratory at the Main Geophysical Observatory (MGO). The air was not dried during sample collection. Attempts were made to obtain samples when the wind speed was >5 m/s and the wind direction corresponded to the predetermined "clean air" sector. The period of record at Bering Island is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Bering Island rose from approximately 346 parts per million by volume (ppmv) in 1986 to 362.6 ppmv in 1993. Measurements from this station are considered indicative of maritime air masses. The period of record at Kotelny Island is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Kotelny Island rose from 356.08 parts per million by volume (ppmv) in 1988 to 358.8 ppmv in 1993. Because Kotelny Island is the northernmost Russian sampling site, measurements from this site serve as a useful comparison to other northern sites (e.g., Alert, Northwest Territories). In late 1989, air sampling began at the Russian site of Kyzylcha, located in the Republic of Uzbekistan. Unfortunately, the desert site at Kyzylcha has been out of operation since mid-1991 due to financial difficulties in Russia. The annual mean value of 359.02 parts per million by volume (ppmv) for 1990, the lone full year of operation, is higher than measurements from other monitoring programs at this latitude [e.g., Niwot Ridge (354.7 ppmv in 1990) and Tae-ahn Peninsula]. Station "C," an open ocean site, in the North Atlantic, east of Greenland, was established in 1968 and was operated in cooperation with NOAA's National Weather Service through 1973. The Main Geophysical Observatory collected flask samples at the site from January 1983 through October 1990. The yearly mean atmospheric CO concentration at Station "C" rose from 348.15 parts per million by volume (ppmv) in 1985 to 354.33 ppmv in 1989. The period of record at Teriberka Station is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Teriberka Station rose from 354.8 parts per million by volume (ppmv) in 1989 to 358.7 ppmv in 1993.

  7. Toxicity of airborne dust as an indicator of moisture problems in school buildings.

    PubMed

    Tirkkonen, Jenni; Täubel, Martin; Leppänen, Hanna; Peltonen, Matti; Lindsley, William; Chen, Bean T; Hyvärinen, Anne; Hirvonen, Maija-Riitta; Huttunen, Kati

    2017-02-01

    Moisture-damaged indoor environments are thought to increase the toxicity of indoor air particulate matter (PM), indicating that a toxicological assay could be used as a method for recognizing buildings with indoor air problems. We aimed to test if our approach of analyzing the toxicity of actively collected indoor air PM in vitro differentiates moisture-damaged from non-damaged school buildings. We collected active air samples with NIOSH Bioaerosol Cyclone Samplers from moisture-damaged (index) and non-damaged (reference) school buildings (4 + 4). The teachers and pupils of the schools were administered a symptom questionnaire. Five samples of two size fractions [Stage 1 (>1.9 μm) and Stage 2 (1-1.9 μm)] were collected from each school. Mouse RAW264.7 macrophages were exposed to the collected PM for 24 h and subsequently analyzed for changes in cell metabolic activity, production of nitric oxide (NO), tumor necrosis factor (TNF)-α and interleukin (IL)-6. The teachers working in the moisture-damaged schools reported respiratory symptoms such as cough (p = 0.01) and shortness of breath (p = 0.01) more often than teachers from reference schools. Toxicity of the PM sample as such did not differentiate index from reference building,s but the toxicity adjusted for the amount of the particles tended to be higher in moisture-damaged schools. Further development of the method will require identification of other confounding factors in addition to the necessity to adjust for differences in particle counts between samples.

  8. It's Alive!: Students Observe Air-Water Interface Samples Rich with Organisms

    ERIC Educational Resources Information Center

    Avant, Thomas

    2002-01-01

    This article describes an experiment, designed by Cindy Henk, manager of the Socolofsky Microscopy Center at Louisiana State University (LSU), that involved collecting and viewing microorganisms in the air-water interface. The experiment was participated by Leesville High School microbiology students. The students found that the air-water…

  9. Biobriefcase electrostatic aerosol collector

    DOEpatents

    Bell, Perry M [Tracy, CA; Christian, Allen T [Madison, WI; Bailey, Christopher G [Pleasanton, CA; Willis, Ladona [Manteca, CA; Masquelier, Donald A [Tracy, CA; Nasarabadi, Shanavaz L [Livermore, CA

    2009-03-17

    A system for sampling air and collecting particles entrained in the air comprising a receiving surface, a liquid input that directs liquid to the receiving surface and produces a liquid surface, an air input that directs the air so that the air with particles entrained in the air impact the liquid surface, and an electrostatic contact connected to the liquid that imparts an electric charge to the liquid. The particles potentially including bioagents become captured in the liquid by the air with particles entrained in the air impacting the liquid surface. Collection efficiency is improved by the electrostatic contact electrically charging the liquid. The effects of impaction and adhesion due to electrically charging the liquid allows a unique combination in a particle capture medium that has a low fluid consumption rate while maintaining high efficiency.

  10. Mercury concentrations and distribution in soil, water, mine waste leachates, and air in and around mercury mines in the Big Bend region, Texas, USA.

    PubMed

    Gray, John E; Theodorakos, Peter M; Fey, David L; Krabbenhoft, David P

    2015-02-01

    Samples of soil, water, mine waste leachates, soil gas, and air were collected from areas mined for mercury (Hg) and baseline sites in the Big Bend area, Texas, to evaluate potential Hg contamination in the region. Soil samples collected within 300 m of an inactive Hg mine contained elevated Hg concentrations (3.8-11 µg/g), which were considerably higher than Hg in soil collected from baseline sites (0.03-0.05 µg/g) distal (as much as 24 km) from mines. Only three soil samples collected within 300 m of the mine exceeded the probable effect concentration for Hg of 1.06 µg/g, above which harmful effects are likely to be observed in sediment-dwelling organisms. Concentrations of Hg in mine water runoff (7.9-14 ng/L) were generally higher than those found in springs and wells (0.05-3.1 ng/L), baseline streams (1.1-9.7 ng/L), and sources of drinking water (0.63-9.1 ng/L) collected in the Big Bend region. Concentrations of Hg in all water samples collected in this study were considerably below the 2,000 ng/L drinking water Hg guideline and the 770 ng/L guideline recommended by the U.S. Environmental Protection Agency (USEPA) to protect aquatic wildlife from chronic effects of Hg. Concentrations of Hg in water leachates obtained from leaching of mine wastes varied widely from <0.001 to 760 µg of Hg in leachate/g of sample leached, but only one leachate exceeded the USEPA Hg industrial soil screening level of 31 µg/g. Concentrations of Hg in soil gas collected at mined sites (690-82,000 ng/m(3)) were highly elevated compared to soil gas collected from baseline sites (1.2-77 ng/m(3)). However, air collected from mined areas at a height of 2 m above the ground surface contained concentrations of Hg (4.9-64 ng/m(3)) that were considerably lower than Hg in soil gas from the mined areas. Although concentrations of Hg emitted from mine-contaminated soils and mine wastes were elevated, persistent wind in southwest Texas disperses Hg in the air within a few meters of the ground surface.

  11. Uncertainties in monitoring of SVOCs in air caused by within-sampler degradation during active and passive air sampling

    NASA Astrophysics Data System (ADS)

    Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Přibylová, Petra; Vojta, Šimon; Kohoutek, Jiří; Lammel, Gerhard; Klánová, Jana

    2017-10-01

    Degradation of semivolatile organic compounds (SVOCs) occurs naturally in ambient air due to reactions with reactive trace gases (e.g., ozone, NOx). During air sampling there is also the possibility for degradation of SVOCs within the air sampler, leading to underestimates of ambient air concentrations. We investigated the possibility of this sampling artifact in commonly used active and passive air samplers for seven classes of SVOCs, including persistent organic pollutants (POPs) typically covered by air monitoring programs, as well as SVOCs of emerging concern. Two active air samplers were used, one equipped with an ozone denuder and one without, to compare relative differences in mass of collected compounds. Two sets of passive samplers were also deployed to determine the influence of degradation during longer deployment times in passive sampling. In active air samplers, comparison of the two sampling configurations suggested degradation of particle-bound polycyclic aromatic hydrocarbons (PAHs), with concentrations up to 2× higher in the denuder-equipped sampler, while halogenated POPs did not have clear evidence of degradation. In contrast, more polar, reactive compounds (e.g., organophosphate esters and current use pesticides) had evidence of losses in the sampler with denuder. This may be caused by the denuder itself, suggesting sampling bias for these compounds can be created when typical air sampling apparatuses are adapted to limit degradation. Passive air samplers recorded up to 4× higher concentrations when deployed for shorter consecutive sampling periods, suggesting that within-sampler degradation may also be relevant in passive air monitoring programs.

  12. Monitoring of Microscopic Filamentous Fungi in Indoor Air of Transplant Unit.

    PubMed

    Holý, Ondřej; Matoušková, Ivanka; Kubátová, Alena; Hamal, Petr; Svobodová, Lucie; Jurásková, Eva; Raida, Luděk

    2015-12-01

    The aim of the study was to control the microbial contamination of indoor air monitored monthly at the Transplant Unit of the University Hospital Olomouc from August 2010 to July 2011. The unit is equipped with a three-stage air filtration system with HEPA filters. The MAS-100 air sampler (Merck, GER) was used. Twenty locations were singled out for the purposes of collecting a total of 720 samplings of the indoor air. Swabs of the HVAC diffusers at the sampling locations were always carried out after the sampling of the indoor air. In total, 480 samples of the indoor air were taken for Sabouraud chloramphenicol agar. In 11 cases (2.29%) the cultivation verified the presence of microscopic filamentous fungi. Only two cases involved the sanitary facilities of a patient isolation box; the other positive findings were from the facilities. The most frequent established genus was Aspergillus spp. (4x), followed by Trichoderma spp. (2x) and Penicillium spp. (2x), Paecilomyces spp., Eurotium spp., and Chrysonilia spp. (1x each). In 2 cases the cultivation established sterile aerial mycelium, unfortunately no further identification was possible. A total of 726 swabs of HVAC diffusers were collected (2 positive-0.28%). The study results demonstrated the efficacy of the HVAC equipment. With the continuing increase in the number of severely immunocompromised patients, hospitals are faced with the growing problem of invasive aspergillosis and other opportunistic infections. Preventive monitoring of microbial air contaminants is of major importance for the control of invasive aspergillosis. Copyright© by the National Institute of Public Health, Prague 2015.

  13. Herbal dryer: drying of ginger (zingiber officinale) using tray dryer

    NASA Astrophysics Data System (ADS)

    Haryanto, B.; Hasibuan, R.; Alexander; Ashari, M.; Ridha, M.

    2018-02-01

    Drying is widely used as a method to preserve food because of its convenience and affordability. Drying of ginger using tray dryer were carried out at various drying conditions, such as air-drying flow, air-drying temperature, and sample dimensions, to achieve the highest drying rate. Samples with various dimensions were placed in the tray dryer and dried using various air-drying flow and temperatures. The weights of samples were observed every 3 minutes interval. Drying was stopped after three times of constant weighing. Data of drying was collected to make the drying curves. Drying curves show that the highest drying rate is achieved using highest air flow and temperature.

  14. Polybrominated diphenyl ether (PBDE) concentrations and resulting exposure in homes in California: relationships among passive air, surface wipe and dust concentrations, and temporal variability

    PubMed Central

    Bennett, D. H.; Moran, R. E.; Wu, X. (May); Tulve, N. S.; Clifton, M. S.; Colón, M.; Weathers, W.; Sjödin, A.; Jones, R.; Hertz-Picciotto, I.

    2016-01-01

    Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive air, floor and indoor window surface wipes, and dust samples (investigator collected using an HVS3 and vacuum cleaner) in each home. PentaBDE and BDE209 were detected in the majority of the dust samples and many floor wipe samples, but the detection in air and window wipe samples was relatively low. Concentrations of each PBDE congener in different indoor environmental media were moderately correlated, with correlation coefficients ranging between 0.42 and 0.68. Correlation coefficients with blood levels were up to 0.65 and varied between environmental media and age group. Both investigator-collected dust and floor wipes were correlated with serum levels for a wide range of congeners. These two sample types also had a relatively high fraction of samples with adequate mass for reliable quantification. In 42 homes, PBDE levels measured in the same environmental media in the same home 1 year apart were statistically correlated (correlation coefficients: 0.57–0.90), with the exception of BDE209 which was not well correlated longitudinally. PMID:24832910

  15. Personal exposure to JP-8 jet fuel vapors and exhaust at air force bases.

    PubMed

    Pleil, J D; Smith, L B; Zelnick, S D

    2000-03-01

    JP-8 jet fuel (similar to commercial/international jet A-1 fuel) is the standard military fuel for all types of vehicles, including the U.S. Air Force aircraft inventory. As such, JP-8 presents the most common chemical exposure in the Air Force, particularly for flight and ground crew personnel during preflight operations and for maintenance personnel performing routine tasks. Personal exposure at an Air Force base occurs through occupational exposure for personnel involved with fuel and aircraft handling and/or through incidental exposure, primarily through inhalation of ambient fuel vapors. Because JP-8 is less volatile than its predecessor fuel (JP-4), contact with liquid fuel on skin and clothing may result in prolonged exposure. The slowly evaporating JP-8 fuel tends to linger on exposed personnel during their interaction with their previously unexposed colleagues. To begin to assess the relative exposures, we made ambient air measurements and used recently developed methods for collecting exhaled breath in special containers. We then analyzed for certain volatile marker compounds for JP-8, as well as for some aromatic hydrocarbons (especially benzene) that are related to long-term health risks. Ambient samples were collected by using compact, battery-operated, personal whole-air samplers that have recently been developed as commercial products; breath samples were collected using our single-breath canister method that uses 1-L canisters fitted with valves and small disposable breathing tubes. We collected breath samples from various groups of Air Force personnel and found a demonstrable JP-8 exposure for all subjects, ranging from slight elevations as compared to a control cohort to > 100 [mutilpe] the control values. This work suggests that further studies should be performed on specific issues to obtain pertinent exposure data. The data can be applied to assessments of health outcomes and to recommendations for changes in the use of personal protective equipment that optimize risk reduction without undue impact on a mission.

  16. Formaldehyde Exposures in a University Anatomy Laboratory

    NASA Astrophysics Data System (ADS)

    Winkler, Kyle William

    Air sampling studies were conducted within a university anatomical laboratory during the embalmment of a cadaver in order to determine if dangerous concentrations of formaldehyde existed. Three air sampling studies were conducted in the anatomical laboratory on three separate days that a cadaver was being embalmed. Samples were collected and analyzed using the Occupational Safety and Health Administration (OSHA) Sampling and Analytical Methods: Method 52. Each air sampling study sampled for short term exposure limit (STEL) and time weighted mean (TWA) breathing zone formaldehyde concentrations as well as area TWA formaldehyde concentrations. A personal aldehyde monitor was also used in each air sampling study to sample for breathing zone formaldehyde concentrations. Measured TWA mean exposures to formaldehyde ranged from 0.15--1.3 parts per million (ppm), STEL formaldehyde exposures ranged from 0.019--0.64 ppm, and eight-hour TWAs ranged from 0.03 to 3.6 ppm. All 8-hour TWA formaldehyde concentrations sampled in the anatomy laboratory during an embalmment were less than the permissible exposure limit (PEL) required by OSHA.

  17. Aethalometer™ Instrument Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sedlacek, Arthur J.

    2016-04-01

    The Aethalometer is an instrument that provides a real-time readout of the concentration of “Black” or “Elemental” carbon aerosol particles (BC or E) in an air stream (see Figure 1 and Figure 2). It is a self-contained instrument that measures the rate of change of optical transmission through a spot on a filter where aerosol is being continuously collected and uses the information to calculate the concentration of optically absorbing material in the sampled air stream. The instrument measures the transmitted light intensities through the “sensing” portion of the filter, on which the aerosol spot is being collected, and amore » “reference” portion of the filter as a check on the stability of the optical source. A mass flowmeter monitors the sample air flow rate. The data from these three measurements is used to determine the mean BC content of the air stream.« less

  18. AirLab: a cloud-based platform to manage and share antibody-based single-cell research.

    PubMed

    Catena, Raúl; Özcan, Alaz; Jacobs, Andrea; Chevrier, Stephane; Bodenmiller, Bernd

    2016-06-29

    Single-cell analysis technologies are essential tools in research and clinical diagnostics. These methods include flow cytometry, mass cytometry, and other microfluidics-based technologies. Most laboratories that employ these methods maintain large repositories of antibodies. These ever-growing collections of antibodies, their multiple conjugates, and the large amounts of data generated in assays using specific antibodies and conditions makes a dedicated software solution necessary. We have developed AirLab, a cloud-based tool with web and mobile interfaces, for the organization of these data. AirLab streamlines the processes of antibody purchase, organization, and storage, antibody panel creation, results logging, and antibody validation data sharing and distribution. Furthermore, AirLab enables inventory of other laboratory stocks, such as primers or clinical samples, through user-controlled customization. Thus, AirLab is a mobile-powered and flexible tool that harnesses the capabilities of mobile tools and cloud-based technology to facilitate inventory and sharing of antibody and sample collections and associated validation data.

  19. Sensor-triggered sampling to determine instantaneous airborne vapor exposure concentrations.

    PubMed

    Smith, Philip A; Simmons, Michael K; Toone, Phillip

    2018-06-01

    It is difficult to measure transient airborne exposure peaks by means of integrated sampling for organic chemical vapors, even with very short-duration sampling. Selection of an appropriate time to measure an exposure peak through integrated sampling is problematic, and short-duration time-weighted average (TWA) values obtained with integrated sampling are not likely to accurately determine actual peak concentrations attained when concentrations fluctuate rapidly. Laboratory analysis for integrated exposure samples is preferred from a certainty standpoint over results derived in the field from a sensor, as a sensor user typically must overcome specificity issues and a number of potential interfering factors to obtain similarly reliable data. However, sensors are currently needed to measure intra-exposure period concentration variations (i.e., exposure peaks). In this article, the digitized signal from a photoionization detector (PID) sensor triggered collection of whole-air samples when toluene or trichloroethylene vapors attained pre-determined levels in a laboratory atmosphere generation system. Analysis by gas chromatography-mass spectrometry of whole-air samples (with both 37 and 80% relative humidity) collected using the triggering mechanism with rapidly increasing vapor concentrations showed good agreement with the triggering set point values. Whole-air samples (80% relative humidity) in canisters demonstrated acceptable 17-day storage recoveries, and acceptable precision and bias were obtained. The ability to determine exceedance of a ceiling or peak exposure standard by laboratory analysis of an instantaneously collected sample, and to simultaneously provide a calibration point to verify the correct operation of a sensor was demonstrated. This latter detail may increase the confidence in reliability of sensor data obtained across an entire exposure period.

  20. PM2.5 Monitors in New England | Air Quality Planning Unit ...

    EPA Pesticide Factsheets

    2017-04-10

    The New England states are currently operating a network of 58 ambient PM2.5 air quality monitors that meet EPA's Federal Reference Method (FRM) for PM2.5, which is necessary in order for the resultant data to be used for attainment/non-attainment purposes. These monitors collect particles in the ambient air smaller than 2.5 microns in size on a filter, which is weighed prior and post sampling to produce a 24-hour sample concentration.

  1. Polyfluorinated Compounds in Serum Linked to Indoor Air in Office Environments

    PubMed Central

    Fraser, Alicia J; Webster, Thomas F; Watkins, Deborah J; Nelson, Jessica W; Stapleton, Heather M; Calafat, Antonia M; Kato, Kayoko; Shoeib, Mahiba; Vieira, Verónica M; McClean, Michael D

    2011-01-01

    We aimed to investigate the role of indoor office air on exposure to polyfluorinated compounds (PFCs) among office workers. Week-long, active air sampling was conducted during the winter of 2009 in 31 offices in Boston, MA. Air samples were analyzed for fluorotelomer alcohols (FTOHs), sulfonamides (FOSAs), and sulfonamidoethanols (FOSEs). Serum was collected from each participant (n=31) and analyzed for twelve PFCs including PFOA and PFOS. In air, FTOHs were present in the highest concentrations, particularly 8:2-FTOH (GM=9,920 pg/m3). FTOHs varied significantly by building with the highest levels observed in a newly constructed building. PFOA in serum was significantly correlated with air levels of 6:2-FTOH (r=0.43), 8:2-FTOH (r=0.60), and 10:2-FTOH (r=0.62). Collectively, FTOHs in air significantly predicted PFOA in serum (p < 0.001) and explained approximately 36% of the variation in serum PFOA concentrations. PFOS in serum was not associated with air levels of FOSAs/FOSEs. In conclusion, FTOH concentrations in office air significantly predict serum PFOA concentrations in office workers. Variation in PFC air concentrations by building is likely due to differences in the number, type, and age of potential sources such as carpeting, furniture and/or paint. PMID:22148395

  2. Polyfluorinated compounds in serum linked to indoor air in office environments.

    PubMed

    Fraser, Alicia J; Webster, Thomas F; Watkins, Deborah J; Nelson, Jessica W; Stapleton, Heather M; Calafat, Antonia M; Kato, Kayoko; Shoeib, Mahiba; Vieira, Verónica M; McClean, Michael D

    2012-01-17

    We aimed to investigate the role of indoor office air on exposure to polyfluorinated compounds (PFCs) among office workers. Week-long, active air sampling was conducted during the winter of 2009 in 31 offices in Boston, MA. Air samples were analyzed for fluorotelomer alcohols (FTOHs), sulfonamides (FOSAs), and sulfonamidoethanols (FOSEs). Serum was collected from each participant (n = 31) and analyzed for 12 PFCs including PFOA and PFOS. In air, FTOHs were present in the highest concentrations, particularly 8:2-FTOH (GM = 9920 pg/m(3)). FTOHs varied significantly by building with the highest levels observed in a newly constructed building. PFOA in serum was significantly correlated with air levels of 6:2-FTOH (r = 0.43), 8:2-FTOH (r = 0.60), and 10:2-FTOH (r = 0.62). Collectively, FTOHs in air significantly predicted PFOA in serum (p < 0.001) and explained approximately 36% of the variation in serum PFOA concentrations. PFOS in serum was not associated with air levels of FOSAs/FOSEs. In conclusion, FTOH concentrations in office air significantly predict serum PFOA concentrations in office workers. Variation in PFC air concentrations by building is likely due to differences in the number, type, and age of potential sources such as carpeting, furniture, and/or paint.

  3. Longitudinal Metagenomic Analysis of Hospital Air Identifies Clinically Relevant Microbes.

    PubMed

    King, Paula; Pham, Long K; Waltz, Shannon; Sphar, Dan; Yamamoto, Robert T; Conrad, Douglas; Taplitz, Randy; Torriani, Francesca; Forsyth, R Allyn

    2016-01-01

    We describe the sampling of sixty-three uncultured hospital air samples collected over a six-month period and analysis using shotgun metagenomic sequencing. Our primary goals were to determine the longitudinal metagenomic variability of this environment, identify and characterize genomes of potential pathogens and determine whether they are atypical to the hospital airborne metagenome. Air samples were collected from eight locations which included patient wards, the main lobby and outside. The resulting DNA libraries produced 972 million sequences representing 51 gigabases. Hierarchical clustering of samples by the most abundant 50 microbial orders generated three major nodes which primarily clustered by type of location. Because the indoor locations were longitudinally consistent, episodic relative increases in microbial genomic signatures related to the opportunistic pathogens Aspergillus, Penicillium and Stenotrophomonas were identified as outliers at specific locations. Further analysis of microbial reads specific for Stenotrophomonas maltophilia indicated homology to a sequenced multi-drug resistant clinical strain and we observed broad sequence coverage of resistance genes. We demonstrate that a shotgun metagenomic sequencing approach can be used to characterize the resistance determinants of pathogen genomes that are uncharacteristic for an otherwise consistent hospital air microbial metagenomic profile.

  4. Atmospheric CO2 Records from Sites in the Atmospheric Environment Service Air Sampling Network (1975 and 1994)

    DOE Data Explorer

    Trivett, N. B.A. [Atmospheric Environment Service, Downsview, Ontario, Canada; Hudec, V. C. [Atmospheric Environment Service, Downsview, Ontario, Canada; Wong, C. S. [Marine Carbon Research Centre, Institute of Ocean Sciences, Sidney, British Columbia, Canada

    1997-01-01

    From the mid-1970s through the mid-1990s, air samples were collected for the purposes of monitoring atmospheric CO2 from four sites in the AES air sampling network. Air samples were collected approximately once per week, between 12:00 and 16:00 local time, in a pair of evacuated 2-L thick-wall borosilicate glass flasks. Samples were collected under preferred conditions of wind speed and direction (i.e., upwind of the main station and when winds are strong and steady). The flasks were evacuated to pressures of ~1 × 10-4 mbar or 0.01 Pa prior to being sent to the stations. The airwas not dried during sample collection. The flask data from Alert show an increase in the annual atmospheric CO2 concentration from 341.35 parts per million by volume (ppmv) in 1981 to 357.21 ppmv in 1991. For Cape St. James, Trivett and Higuchi (1989) reported that the mean annual rate of increase, obtained from the slope of a least-squares regression line through the annual averages, was 1.43 ppmv per year. In August 1992, the weather station at Cape St. James was automated; as a result, the flask sampling program was discontinued at this site. Estevan Point, on the West Coast of Vancouver Island, was chosen as a replacement station. Sampling at Estevan Point started in 1992; thus, the monthly and annual CO2record from Estevan Point is too short to show any long-term trends. The sampling site at Sable Island, off the coast of Nova Scotia, was established in 1975. The flask data from Sable Island show an increase in the annual atmospheric CO2 concentration from 334.49 parts per million by volume (ppmv) in 1977 (the first full year of data) to 356.02 ppmv in 1990. For Sable Island, Trivett and Higuchi (1989) reported that the mean annual rate of increase, obtained from the slope of a least-squares regression line through the annual averages, was 1.48 ppmv per year.

  5. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... filters, or for replacement of equipment needing major repair. (c) Filters shall be analyzed and concentrations calculated within 30 days after filters are collected. Records of concentrations at all sampling...

  6. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... filters, or for replacement of equipment needing major repair. (c) Filters shall be analyzed and concentrations calculated within 30 days after filters are collected. Records of concentrations at all sampling...

  7. Microbial Contamination on Used Surgical Masks among Hospital Personnel and Microbial Air Quality in their Working Wards: A Hospital in Bangkok

    PubMed Central

    Luksamijarulkul, Pipat; Aiempradit, Natkitta; Vatanasomboon, Pisit

    2014-01-01

    Objective To assess the relationship of bacterial and fungal contamination on used surgical masks worn by the hospital personnel and microbial air quality in their working wards. Methods This is a cross-sectional study of 230 used surgical masks collected from 214 hospital personnel, and 215 indoor air samples collected from their working wards to culture for bacterial and fungal counts. This study was carried out at the hospital in Bangkok. Group or genus of isolated bacteria and fungi were preliminarily identified by Gram’s stain and lacto-phenol cotton blue. Data were analyzed using paired t-test and Pearson’s correlation coefficient at the significant level of p<0.050. Results Means and standard deviation of bacterial and fungal contamination on inside area of the used masks were 47 ± 56 and 15 ± 9 cfu/ml/piece, and on outside area were 166 ± 199 and 34 ± 18 cfu/ml/piece, respectively, p<0.001. The bacterial and fungal contamination on used masks from hospital personnel working in the male and female medical wards and out-patient department, as well as the bacterial and fungal counts of the indoor air sample collected from the same area were relatively higher than the other wards. The predominant isolated bacteria and fungi contaminated on inside and outside areas of the used masks and air samples were similar (Staphylococcus spp. and Aspergillus spp.; respectively). For its relationship, results found that bacterial and fungal counts in air samples showed significantly positive correlation with the bacterial contamination load on outside area of the used masks, r=0.16, p=0.018 and r=0.21, p=0.003, respectively. Conclusion High bacterial contamination on outside area of the used masks was demonstrated, and it showed a significant correlation with microbial air quality of working wards. PMID:25337311

  8. Microbial Contamination on Used Surgical Masks among Hospital Personnel and Microbial Air Quality in their Working Wards: A Hospital in Bangkok.

    PubMed

    Luksamijarulkul, Pipat; Aiempradit, Natkitta; Vatanasomboon, Pisit

    2014-09-01

    To assess the relationship of bacterial and fungal contamination on used surgical masks worn by the hospital personnel and microbial air quality in their working wards. This is a cross-sectional study of 230 used surgical masks collected from 214 hospital personnel, and 215 indoor air samples collected from their working wards to culture for bacterial and fungal counts. This study was carried out at the hospital in Bangkok. Group or genus of isolated bacteria and fungi were preliminarily identified by Gram's stain and lacto-phenol cotton blue. Data were analyzed using paired t-test and Pearson's correlation coefficient at the significant level of p<0.050. Means and standard deviation of bacterial and fungal contamination on inside area of the used masks were 47 ± 56 and 15 ± 9 cfu/ml/piece, and on outside area were 166 ± 199 and 34 ± 18 cfu/ml/piece, respectively, p<0.001. The bacterial and fungal contamination on used masks from hospital personnel working in the male and female medical wards and out-patient department, as well as the bacterial and fungal counts of the indoor air sample collected from the same area were relatively higher than the other wards. The predominant isolated bacteria and fungi contaminated on inside and outside areas of the used masks and air samples were similar (Staphylococcus spp. and Aspergillus spp.; respectively). For its relationship, results found that bacterial and fungal counts in air samples showed significantly positive correlation with the bacterial contamination load on outside area of the used masks, r=0.16, p=0.018 and r=0.21, p=0.003, respectively. High bacterial contamination on outside area of the used masks was demonstrated, and it showed a significant correlation with microbial air quality of working wards.

  9. Applicability of the Environmental Relative Moldiness Index for Quantification of Residential Mold Contamination in an Air Pollution Health Effects Study

    EPA Science Inventory

    As part of the Near-Road Exposures and Effects of Urban Air Pollutants Study (NEXUS) investigating the respiratory health impacts of traffic-related air pollutants on asthmatic children in Detroit, Michigan, residential dust samples were collected to quantify mold exposure. Sett...

  10. Participant-Based Monitoring of Indoor and Outdoor Nitrogen Dioxide, Volatile Organic Compounds, and Polycyclic Aromatic Hydrocarbons among MICA-Air Households

    EPA Science Inventory

    The Mechanistic Indicators of Childhood Asthma (MICA) study in Detroit, Michigan introduced a participant-based approach to reduce the resource burden associated with collection of indoor and outdoor residential air sampling data. A subset of participants designated as MICA-Air c...

  11. A COMPARATIVE ASSESSMENT OF BOISE, IDAHO, AMBIENT AIR FINE PARTICLE SAMPLES USING THE PLATE AND MICROSUSPENSION SALMONELLA MUTAGENICITY ASSAYS

    EPA Science Inventory

    The primary objective of this study is to characterize the genotoxic potential of the ambient air aerosols collected within an air shed impacted primarily by wood smoke and automotive emissions. The study also examines the relative merits of a microsuspension assay and the standa...

  12. Airborne pesticide residues along the Mississippi River

    USGS Publications Warehouse

    Majewski, M.S.; Foreman, W.T.; Goolsbys, D.A.; Nakagaki, N.

    1998-01-01

    The occurrence, concentration, and geographical distribution of agricultural pesticides were determined in air over the Mississippi River from New Orleans, LA, to St. Paul, MN, during the first 10 days of June 1994. Air samples were collected from a research vessel by pulling air through polyurethane foam plugs at about 100 L/min for up to 24 h. Each sample was analyzed for 42 pesticides and 3 pesticide transformation products. Twenty- five compounds-15 herbicides, 7 insecticides, and 3 pesticide transformation products-were detected in one or more samples with concentrations ranging from 0.05 to 80 ng/m3. Alachlor, chlorpyrifos, diazinon, fonofos, malathion, methyl parathion, metolachlor, metribuzin, pendimethalin, and trifluralin were detected in 80% or more of the samples. The highest concentrations for chlorpyrifos (1.6 ng/m3), diazinon (0.36 ng/m3), and malathion (4.6 ng/m3) all occurred near major metropolitan areas. These samples represent a 'snapshot in time', a spatial and temporal integration of which pesticides were present in the air during each sampling period. The occurrence and atmospheric concentrations of the observed pesticides were most closely related to their use on cropland within 40 km of the river.The occurrence, concentration, and geographical distribution of agricultural pesticides were determined in air over the Mississippi River from New Orleans, LA, to St. Paul, MN, during the first 10 days of June 1994. Air samples were collected from a research vessel by pulling air through polyurethane foam plugs at about 100 L/min for up to 24 h. Each sample was analyzed for 42 pesticides and 3 pesticide transformation products. Twenty-five compounds-15 herbicides, 7 insecticides, and 3 pesticide transformation products-were detected in one or more samples with concentrations ranging from 0.05 to 80 ng/m3. Alachlor, chlorpyrifos, diazinon, fonofos, malathion, methyl parathion, metolachlor, metribuzin, pendimethalin, and trifluralin were detected in 80% or more of the samples. The highest concentrations for chlorpyrifos (1.6 ng/m3), diazinon (0.36 ng/m3), and malathion (4.6 ng/m3) all occurred near major metropolitan areas. These samples represent a 'snapshot in time', a spatial and temporal integration of which pesticides were present in the air during each sampling period. The occurrence and atmospheric concentrations of the observed pesticides were most closely related to their use on cropland within 40 km of the river.

  13. Predicting Air Quality at First Ingress into Vehicles Visiting the International Space Station.

    PubMed

    Romoser, Amelia A; Scully, Robert R; Limero, Thomas F; De Vera, Vanessa; Cheng, Patti F; Hand, Jennifer J; James, John T; Ryder, Valerie E

    2017-02-01

    NASA regularly performs ground-based offgas tests (OGTs), which allow prediction of accumulated volatile pollutant concentrations at first entry on orbit, on whole modules and vehicles scheduled to connect to the International Space Station (ISS). These data guide crew safety operations and allow for estimation of ISS air revitalization systems impact from additional pollutant load. Since volatiles released from vehicle, module, and payload materials can affect crew health and performance, prediction of first ingress air quality is important. To assess whether toxicological risk is typically over or underpredicted, OGT and first ingress samples from 10 vehicles and modules were compared. Samples were analyzed by gas chromatography and gas chromatography-mass spectrometry. The rate of pollutant accumulation was extrapolated over time. Ratios of analytical values and Spacecraft Maximum Allowable Concentrations were used to predict total toxicity values (T-values) at first entry. Results were also compared by compound. Frequently overpredicted was 2-butanone (9/10), whereas propanal (6/10) and ethanol (8/10) were typically underpredicted, but T-values were not substantially affected. Ingress sample collection delay (estimated by octafluoropropane introduced from ISS atmosphere) and T-value prediction accuracy correlated well (R2 = 0.9008), highlighting the importance of immediate air sample collection and accounting for ISS air dilution. Importantly, T-value predictions were conservative 70% of the time. Results also suggest that T-values can be normalized to octafluoropropane levels to adjust for ISS air dilution at first ingress. Finally, OGT and ingress sampling has allowed small leaks in vehicle fluid systems to be recognized and addressed.Romoser AA, Scully RR, Limero TF, De Vera V, Cheng PF, Hand JJ, James JT, Ryder VE. Predicting air quality at first ingress into vehicles visiting the International Space Station. Aerosp Med Hum Perform. 2017; 88(2):104-113.

  14. Identifying source regions for the atmospheric input of PCDD/Fs to the Baltic Sea

    NASA Astrophysics Data System (ADS)

    Sellström, Ulla; Egebäck, Anna-Lena; McLachlan, Michael S.

    PCDD/F contamination of the Baltic Sea has resulted in the European Union imposing restrictions on the marketing of several fish species. Atmospheric deposition is the major source of PCDD/Fs to the Baltic Sea, and hence there is a need to identify the source regions of the PCDD/Fs in ambient air over the Baltic Sea. A novel monitoring strategy was employed to address this question. During the winter of 2006-2007 air samples were collected in Aspvreten (southern Sweden) and Pallas (northern Finland). Short sampling times (24 h) were employed and only samples with stable air mass back trajectories were selected for analysis of the 2,3,7,8-substituted PCDD/F congeners. The range in the PCDD/F concentrations from 40 samples collected at Aspvreten was a factor of almost 50 (range 0.6-29 fg TEQ/m 3). When the samples were grouped according to air mass origin into seven compass sectors, the variability was much lower (typically less than a factor of 3). This indicates that air mass origin was the primary source of the variability. The contribution of each sector to the PCDD/F contamination over the Baltic Sea during the winter half year of 2006/2007 was calculated from the average PCDD/F concentration for each sector and the frequency with which the air over the Baltic Sea came from that sector. Air masses originating from the south-southwest, south-southeast and east segments contributed 65% of the PCDDs and 75% of the PCDFs. Strong correlations were obtained between the concentrations of most of the PCDD/F congeners and the concentration of soot. These correlations can be used to predict the PCDD/F concentrations during the winter half year from inexpensive soot measurements.

  15. A novel atmospheric tritium sampling system

    NASA Astrophysics Data System (ADS)

    Qin, Lailai; Xia, Zhenghai; Gu, Shaozhong; Zhang, Dongxun; Bao, Guangliang; Han, Xingbo; Ma, Yuhua; Deng, Ke; Liu, Jiayu; Zhang, Qin; Ma, Zhaowei; Yang, Guo; Liu, Wei; Liu, Guimin

    2018-06-01

    The health hazard of tritium is related to its chemical form. Sampling different chemical forms of tritium simultaneously becomes significant. Here a novel atmospheric tritium sampling system (TS-212) was developed to collect the tritiated water (HTO), tritiated hydrogen (HT) and tritiated methane (CH3T) simultaneously. It consisted of an air inlet system, three parallel connected sampling channels, a hydrogen supply module, a methane supply module and a remote control system. It worked at air flow rate of 1 L/min to 5 L/min, with temperature of catalyst furnace at 200 °C for HT sampling and 400 °C for CH3T sampling. Conversion rates of both HT and CH3T to HTO were larger than 99%. The collecting efficiency of the two-stage trap sets for HTO was larger than 96% in 12 h working-time without being blocked. Therefore, the collected efficiencies of TS-212 are larger than 95% for tritium with different chemical forms in environment. Besides, the remote control system made sampling more intelligent, reducing the operator's work intensity. Based on the performance parameters described above, the TS-212 can be used to sample atmospheric tritium in different chemical forms.

  16. Legacy and currently used pesticides in the atmospheric environment of Lake Victoria, East Africa.

    PubMed

    Arinaitwe, Kenneth; Kiremire, Bernard T; Muir, Derek C G; Fellin, Phil; Li, Henrik; Teixeira, Camilla; Mubiru, Drake N

    2016-02-01

    The Lake Victoria watershed has extensive agricultural activity with a long history of pesticide use but there is limited information on historical use or on environmental levels. To address this data gap, high volume air samples were collected from two sites close to the northern shore of Lake Victoria; Kakira (KAK) and Entebbe (EBB). The samples, to be analyzed for pesticides, were collected over various periods between 1999 and 2004 inclusive (KAK 1999-2000, KAK 2003-2004, EBB 2003 and EBB 2004 sample sets) and from 2008 to 2010 inclusive (EBB 2008, EBB 2009 and EBB 2010 sample sets). The latter sample sets (which also included precipitation samples) were also analyzed for currently used pesticides (CUPs) including chlorpyrifos, chlorthalonil, metribuzin, trifluralin, malathion and dacthal. Chlorpyrifos was the predominant CUP in air samples with average concentrations of 93.5, 26.1 and 3.54 ng m(-3) for the EBB 2008, 2009, 2010 sample sets, respectively. Average concentrations of total endosulfan (ΣEndo), total DDT related compounds (ΣDDTs) and hexachlorocyclohexanes (ΣHCHs) ranged from 12.3-282, 22.8-130 and 3.72-81.8 pg m(-3), respectively, for all the sample sets. Atmospheric prevalence of residues of persistent organic pollutants (POPs) increased with fresh emissions of endosulfan, DDT and lindane. Hexachlorobenzene (HCB), pentachlorobenzene (PeCB) and dieldrin were also detected in air samples. Transformation products, pentachloroanisole, 3,4,5-trichloroveratrole and 3,4,5,6-tetrachloroveratrole, were also detected. The five most prevalent compounds in the precipitation samples were in the order chlorpyrifos>chlorothalonil>ΣEndo>ΣDDTs>ΣHCHs with average fluxes of 1123, 396, 130, 41.7 and 41.3 ng m(-2)sample(-1), respectively. PeCB exceeded HCB in precipitation samples. The reverse was true for air samples. Backward air trajectories suggested transboundary and local emission sources of the analytes. The results underscore the need for a concerted regional vigilance in management of chemicals. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Instrument to collect fogwater for chemical analysis

    NASA Astrophysics Data System (ADS)

    Jacob, Daniel J.; Waldman, Jed M.; Haghi, Mehrdad; Hoffmann, Michael R.; Flagan, Richard C.

    1985-06-01

    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3-100-μm diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may easily be automated, and is suitable for use in routine air quality monitoring programs.

  18. GAS CHROMATOGRAPHIC TECHNIQUES FOR THE MEASUREMENT OF ISOPRENE IN AIR

    EPA Science Inventory

    The chapter discusses gas chromatographic techniques for measuring isoprene in air. Such measurement basically consists of three parts: (1) collection of sufficient sample volume for representative and accurate quantitation, (2) separation (if necessary) of isoprene from interfer...

  19. Testing of high-volume sampler inlets for the sampling of atmospheric radionuclides.

    PubMed

    Irshad, Hammad; Su, Wei-Chung; Cheng, Yung S; Medici, Fausto

    2006-09-01

    Sampling of air for radioactive particles is one of the most important techniques used to determine the nuclear debris from a nuclear weapon test in the Earth's atmosphere or those particles vented from underground or underwater tests. Massive-flow air samplers are used to sample air for any indication of radionuclides that are a signature of nuclear tests. The International Monitoring System of the Comprehensive Nuclear Test Ban Treaty Organization includes seismic, hydroacoustic, infrasound, and gaseous xenon isotopes sampling technologies, in addition to radionuclide sampling, to monitor for any violation of the treaty. Lovelace Respiratory Research Institute has developed a large wind tunnel to test the outdoor radionuclide samplers for the International Monitoring System. The inlets for these samplers are tested for their collection efficiencies for different particle sizes at various wind speeds. This paper describes the results from the testing of two radionuclide sampling units used in the International Monitoring System. The possible areas of depositional wall losses are identified and the losses in these areas are determined. Sampling inlet type 1 was tested at 2.2 m s wind speed for 5, 10, and 20-microm aerodynamic diameter particles. The global collection efficiency was about 87.6% for 10-microm particles for sampling inlet type 1. Sampling inlet type 2 was tested for three wind speeds at 0.56, 2.2, and 6.6 m s for 5, 10, and 20-microm aerodynamic diameter particles in two different configurations (sampling head lowered and raised). The global collection efficiencies for these configurations for 10-microm particles at 2.2 m s wind speed were 77.4% and 82.5%, respectively. The sampling flow rate was 600 m h for both sampling inlets.

  20. Chemical trends in background air quality and the ionic composition of precipitation for the period 1980-2004 from samples collected at Valentia Observatory, Co. Kerry, Ireland.

    PubMed

    Bashir, Wasim; McGovern, Frank; O'Brien, Phillip; Ryan, Margaret; Burke, Liam; Paull, Brett

    2008-06-01

    A major Irish study, based upon more than 8000 samples collected over the measurement period of 22 years, for sulfur dioxide (SO2-S), sulfate (SO4-S) and nitrogen dioxide (NO2-N) concentrations (microg m(-3)) within air, and the ionic composition of precipitation samples based on sodium (Na+), potassium (K+), magnesium (Mg2+), calcium (Ca2+), chloride (Cl-), sulfate (SO4-S), non-sea salt sulfate (nssSO4-S), ammonium (NH4-N), and nitrate (NO3-N) weighted mean concentrations (mg l(-1)), has been completed. For the air samples, the sulfur dioxide and sulfate concentrations decreased over the sampling period (1980-2004) by 75% and 45%, respectively, whereas no significant trend was observed for nitrogen dioxide. The highest concentrations for sulfur dioxide, sulfate and nitrogen dioxide were associated with wind originating from the easterly and northeasterly directions i.e. those influenced by Irish and European sources. The lowest concentrations were associated with the westerly directions i.e. for air masses originating in the North Atlantic region. This was further verified with the use of backward (back) trajectory analysis, which allowed tracing the movement of air parcels using the European Centre for Medium range Weather Forecasting (ECMWF) ERA-40 re-analysis data. High non-sea salt sulfate levels were being associated with air masses originating from Europe (easterlies) with lower levels from the Atlantic (westerlies). With the precipitation data, analysis of the non-sea salt sulfate concentrations showed a decrease by 47% since the measurements commenced.

  1. Avian influenza H9N2 virus isolated from air samples in LPMs in Jiangxi, China.

    PubMed

    Zeng, Xiaoxu; Liu, Mingbin; Zhang, Heng; Wu, Jingwen; Zhao, Xiang; Chen, Wenbing; Yang, Lei; He, Fenglan; Fan, Guoyin; Wang, Dayan; Chen, Haiying; Shu, Yuelong

    2017-07-24

    Recently, avian influenza virus has caused repeated worldwide outbreaks in humans. Live Poultry Markets (LPMs) play an important role in the circulation and reassortment of novel Avian Influenza Virus (AIVs). Aerosol transmission is one of the most important pathways for influenza virus to spread among poultry, from poultry to mammals, and among mammals. In this study, air samples were collected from LPMs in Nanchang city between April 2014 and March 2015 to investigate possible aerosol transmission of AIVs. Air samples were detected for Flu A by Real-Time Reverse Transcription-Polymerase Chain Reaction (RRT-PCR). If samples were positive for Flu A, they were inoculated into 9- to 10-day-old specific-pathogen-free embryonated eggs. If the result was positive, the whole genome of the virus was sequenced by MiSeq. Phylogenetic trees of all 8 segments were constructed using MEGA 6.05 software. To investigate the possible aerosol transmission of AIVs, 807 air samples were collected from LPMs in Nanchang city between April 2014 and March 2015. Based on RRT-PCR results, 275 samples (34.1%) were Flu A positive, and one virus was successfully isolated with embryonated eggs. The virus shared high nucleotide homology with H9N2 AIVs from South China. Our study provides further evidence that the air in LPMs can be contaminated by influenza viruses and their nucleic acids, and this should be considered when choosing and evaluating disinfection strategies in LPMs, such as regular air disinfection. Aerosolized viruses such as the H9N2 virus detected in this study can increase the risk of human infection when people are exposed in LPMs.

  2. Solid sorbent air sampler

    NASA Technical Reports Server (NTRS)

    Galen, T. J. (Inventor)

    1986-01-01

    A fluid sampler for collecting a plurality of discrete samples over separate time intervals is described. The sampler comprises a sample assembly having an inlet and a plurality of discreet sample tubes each of which has inlet and outlet sides. A multiport dual acting valve is provided in the sampler in order to sequentially pass air from the sample inlet into the selected sample tubes. The sample tubes extend longitudinally of the housing and are located about the outer periphery thereof so that upon removal of an enclosure cover, they are readily accessible for operation of the sampler in an analysis mode.

  3. Multistage open-tube trap for enrichment of part-per-trillion trace components of low-pressure (below 27-kPa) air samples

    NASA Technical Reports Server (NTRS)

    Ohara, D.; Vo, T.; Vedder, J. F.

    1985-01-01

    A multistage open-tube trap for cryogenic collection of trace components in low-pressure air samples is described. The open-tube design allows higher volumetric flow rates than densely packed glass-bead traps commonly reported and is suitable for air samples at pressures below 27 kPa with liquid nitrogen as the cryogen. Gas blends containing 200 to 2500 parts per trillion by volume each of ethane and ethene were sampled and hydrocarbons were enriched with 100 + or - 4 percent trap efficiency. The multistage design is more efficient than equal-length open-tube traps under the conditions of the measurements.

  4. Firn-air Properties and Influences at the West Antarctic Ice Sheet Divide

    NASA Astrophysics Data System (ADS)

    Battle, M. O.; Severinghaus, J. P.; Montzka, S. A.; Sofen, E. D.; Tans, P. P.

    2007-12-01

    In December 2005, we collected samples of firn air from a pair of dedicated boreholes drilled at the West Antarctic Ice Sheet Divide (WAIS-D), immediately adjacent to the WAIS-D deep ice coring effort currently underway at 79° 28'S, 112° 7'W at an elevation of ~1800m. The site is characterized by moderate temperatures (annual mean of -31°C) and moderate accumulation (24 cm/yr ice-equivalent). These samples were analyzed for a wide variety of atmospheric species by laboratories at the Scripps Institution of Oceanography, NOAA-ESRL, University of Colorado/INSTAAR, UC Irvine and Penn. State University. In this presentation, we focus on general properties of the firn air at this site and the influences on its composition, as inferred from concentration data for CO2, CH4, and a range of halogenated species, as well as the stable isotope ratios of N2 and several noble gases. Preliminary analyses indicate the presence of a shallow convective zone (a few meters or less), a diffusive region extending down to roughly 65m and a lock-in zone from 65m to the firn-ice transition at 76.5m. There is also evidence of a thermally-driven seasonal cycle in composition in the upper 25m of the firn. Modeling studies indicate that the accumulation rate at this site is low enough that the downward advection of air accompanying firn compression has a very small influence on the firn air profile. Air at the bottom of the diffusive column has a CO2-based age of 10-15 years (depending on the definition of "mean age"), while the air at the firn-ice transition is ~38 years old. Concentrations of halogenated species in the samples collected imply atmospheric histories that are generally consistent with those derived from direct atmospheric measurements and from firn air collected at other sites. Additional properties of the air, and their controlling processes will also be presented.

  5. Evaluation of Bio-VOC Sampler for Analysis of Volatile Organic Compounds in Exhaled Breath

    PubMed Central

    Kwak, Jae; Fan, Maomian; Harshman, Sean W.; Garrison, Catherine E.; Dershem, Victoria L.; Phillips, Jeffrey B.; Grigsby, Claude C.; Ott, Darrin K.

    2014-01-01

    Monitoring volatile organic compounds (VOCs) from exhaled breath has been used to determine exposures of humans to chemicals. Prior to analysis of VOCs, breath samples are often collected with canisters or bags and concentrated. The Bio-VOC breath sampler, a commercial sampling device, has been recently introduced to the market with growing use. The main advantage for this sampler is to collect the last portion of exhaled breath, which is more likely to represent the air deep in the lungs. However, information about the Bio-VOC sampler is somewhat limited. Therefore, we have thoroughly evaluated the sampler here. We determined the volume of the breath air collected in the sampler was approximately 88 mL. When sampling was repeated multiple times, with the succeeding exhalations applied to a single sorbent tube, we observed linear relationships between the normalized peak intensity and the number of repeated collections with the sampler in many of the breath VOCs detected. No moisture effect was observed on the Tenax sorbent tubes used. However, due to the limitation in the collection volume, the use of the Bio-VOC sampler is recommended only for detection of VOCs present at high concentrations unless repeated collections of breath samples on the sampler are conducted. PMID:25532709

  6. Occurrence and fate of the herbicide glyphosate and its degradate aminomethylphosphonic acid in the atmosphere

    USGS Publications Warehouse

    Chang, Feng-Chih; Simcik, M.F.; Capel, P.D.

    2011-01-01

    This is the first report on the ambient levels of glyphosate, the most widely used herbicide in the United States, and its major degradation product, aminomethylphosphonic acid (AMPA), in air and rain. Concurrent, weekly integrated air particle and rain samples were collected during two growing seasons in agricultural areas in Mississippi and Iowa. Rain was also collected in Indiana in a preliminary phase of the study. The frequency of glyphosate detection ranged from 60 to 100% in both air and rain. The concentrations of glyphosate ranged from 3 and from <0.1 to 2.5 µg/L in air and rain samples, respectively. The frequency of detection and median and maximum concentrations of glyphosate in air were similar or greater to those of the other high-use herbicides observed in the Mississippi River basin, whereas its concentration in rain was greater than the other herbicides. It is not known what percentage of the applied glyphosate is introduced into the air, but it was estimated that up to 0.7% of application is removed from the air in rainfall. Glyphosate is efficiently removed from the air; it is estimated that an average of 97% of the glyphosate in the air is removed by a weekly rainfall ≥30 mm.

  7. Microbiological quality of air in free-range and box-stall stable horse keeping systems.

    PubMed

    Wolny-Koładka, Katarzyna

    2018-04-07

    The aim of this study was to assess the microbiological quality of air in three horse riding centers differing in the horse keeping systems. The air samples were collected in one facility with free-range horse keeping system and two with box stalls of different sizes. The samples were collected over a period of 3 years (2015-2017), four times per year (spring, summer, autumn, winter) to assess the effect of seasonal changes. The prevalence of aerobic mesophilic bacteria, mold fungi, actinomycetes, Staphylococcus spp., and Escherichia coli was determined by the air collision method on Petri dishes with appropriate microbiological media. At the same time, air temperature, relative humidity, and particulate matter concentration (PM 10 , PM 2.5 ) were measured. It was found that the horse keeping system affects the occurrence of the examined airborne microorganisms. Over the 3-year period of study, higher temperature and humidity, as well as particulate matter concentration-which notoriously exceeded limit values-were observed in the facilities with the box-stall system. The air sampled from the largest horse riding center, with the largest number of horses and the box-stall system of horse keeping, was also characterized by the heaviest microbiological contamination. Among others, bacteria from the following genera: Staphylococcus spp., Streptococcus spp., Bacillus spp., and E. coli and fungi from the genera Aspergillus, Fusarium, Mucor, Rhizopus, Penicillium, Trichothecium, Cladosporium, and Alternaria were identified in the analyzed samples.

  8. Fast Estimation of Dietary Fiber Content in Apple.

    PubMed

    Le Gall, Sophie; Even, Sonia; Lahaye, Marc

    2016-02-17

    Dietary fibers (DF) are one of the nutritional benefits of fleshy fruit consumption that is becoming a quality criterion for genetic selection by breeders. However, the AOAC total DF content determination is not readily amenable for screening large fruit collections. A new screening method of DF content in an apple collection based on the automated preparation of cell wall material as an alcohol-insoluble residue (AIR) is proposed. The yield of AIR from 27 apple genotypes was compared with DF measured according to AOAC method 985.29. Although residual protein content in AIRs did not affect DF measurement, subtraction of starch content above 3% dry weight in AIRs was needed to agree with AOAC measured DF. A fast colorimetric screening of starch in AIR was developed to detect samples needing correction. The proposed method may prove useful for the rapid determination of DF in collections of other fleshy fruit besides apple.

  9. NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR METALS IN REPLICATES

    EPA Science Inventory

    This data set includes analytical results for measurements of metals in 490 duplicate (replicate) samples and for particles in 130 duplicate samples. Measurements were made for up to 11 metals in samples of air, dust, water, blood, and urine. Duplicate samples (samples collected ...

  10. Methane mole fraction and δ13C above and below the trade wind inversion at Ascension Island in air sampled by aerial robotics

    NASA Astrophysics Data System (ADS)

    Brownlow, R.; Lowry, D.; Thomas, R. M.; Fisher, R. E.; France, J. L.; Cain, M.; Richardson, T. S.; Greatwood, C.; Freer, J.; Pyle, J. A.; MacKenzie, A. R.; Nisbet, E. G.

    2016-11-01

    Ascension Island is a remote South Atlantic equatorial site, ideal for monitoring tropical background CH4. In September 2014 and July 2015, octocopters were used to collect air samples in Tedlar bags from different heights above and below the well-defined Trade Wind Inversion (TWI), sampling a maximum altitude of 2700 m above mean sea level. Sampling captured both remote air in the marine boundary layer below the TWI and also air masses above the TWI that had been lofted by convective systems in the African tropics. Air above the TWI was characterized by higher CH4, but no distinct shift in δ13C was observed compared to the air below. Back trajectories indicate that lofted CH4 emissions from Southern Hemisphere Africa have bulk δ13CCH4 signatures similar to background, suggesting mixed emissions from wetlands, agriculture, and biomass burning. The campaigns illustrate the usefulness of unmanned aerial system sampling and Ascension's value for atmospheric measurement in an understudied region.

  11. Methane, Nonmethane Hydrocarbons, Alkyl Nitrates, and Chlorinated Carbon Compounds including 3 Chlorofluorocarbons (CFC-11, CFC-12, and CFC-113) in Whole-air Samples (April 1979 – December 2012)

    DOE Data Explorer

    Blake, Donald [University of California, Irvine, Irvine, CA (USA)

    2013-09-01

    Whole-air samples are collected in conditioned, evacuated, 2-L stainless steel canisters; each canister is filled to ambient pressure over a period of about 1 minute (approximately 20 seconds to 2 minutes). These canisters are returned to the University of California at Irvine for chromatographic analysis.

  12. Emissions of fluorides from welding processes.

    PubMed

    Szewczyńska, Małgorzata; Pągowska, Emilia; Pyrzyńska, Krystyna

    2015-11-01

    The levels of fluoride airborne particulates emitted from welding processes were investigated. They were sampled with the patented IOM Sampler, developed by J. H. Vincent and D. Mark at the Institute of Occupational Medicine (IOM), personal inhalable sampler for simultaneous collection of the inhalable and respirable size fractions. Ion chromatography with conductometric detection was used for quantitative analysis. The efficiency of fluoride extraction from the cellulose filter of the IOM sampler was examined using the standard sample of urban air particle matter SRM-1648a. The best results for extraction were obtained when water and the anionic surfactant N-Cetyl-N-N-N-trimethylammonium bromide (CTAB) were used in an ultrasonic bath. The limits of detection and quantification for the whole procedure were 8μg/L and 24μg/L, respectively. The linear range of calibration was 0.01-10mg/L, which corresponds to 0.0001-0.1mg of fluorides per m(3) in collection of a 20L air sample. The concentration of fluorides in the respirable fraction of collected air samples was in the range of 0.20-1.82mg/m(3), while the inhalable fraction contained 0.23-1.96mg/m(3) of fluorides during an eight-hour working day in the welding room. Copyright © 2015. Published by Elsevier B.V.

  13. Slaughterhouses Fungal Burden Assessment: A Contribution for the Pursuit of a Better Assessment Strategy

    PubMed Central

    Viegas, Carla; Faria, Tiago; dos Santos, Mateus; Carolino, Elisabete; Sabino, Raquel; Quintal Gomes, Anita; Viegas, Susana

    2016-01-01

    In slaughterhouses, the biological risk is present not only from the direct or indirect contact with animal matter, but also from the exposure to bioaerosols. Fungal contamination was already reported from the floors and walls of slaughterhouses. This study intends to assess fungal contamination by cultural and molecular methods in poultry, swine/bovine and large animal slaughterhouses. Air samples were collected through an impaction method, while surface samples were collected by the swabbing method and subjected to further macro- and micro-scopic observations. In addition, we collected air samples using the impinger method in order to perform real-time quantitative PCR (qPCR) amplification of genes from specific fungal species, namely A. flavus, A. fumigatus and A. ochraceus complexes. Poultry and swine/bovine slaughterhouses presented each two sampling sites that surpass the guideline of 150 CFU/m3. Scopulariopsis candida was the most frequently isolated (59.5%) in poultry slaughterhouse air; Cladosporium sp. (45.7%) in the swine/bovine slaughterhouse; and Penicillium sp. (80.8%) in the large animal slaughterhouse. Molecular tools successfully amplified DNA from the A. fumigatus complex in six sampling sites where the presence of this fungal species was not identified by conventional methods. This study besides suggesting the indicators that are representative of harmful fungal contamination, also indicates a strategy as a protocol to ensure a proper characterization of fungal occupational exposure. PMID:27005642

  14. Occurrence of the off-host life stages of Tunga penetrans (Siphonaptera) in various environments in Brazil.

    PubMed

    Linardi, P M; Calheiros, C M L; Campelo-Junior, E B; Duarte, E M; Heukelbach, J; Feldmeier, H

    2010-06-01

    To explore the local transmission dynamics of Tunga penetrans in brazil, 134 soil samples from various environments were collected in three different endemic regions of the country and checked for the presence of the flea's larvae, pupae and adults. the samples, which came from an urban slum in the north-east, a village of xavante indians in the central-west and a community of yanomami indians living in traditional longhouses (malocas) in the north, were categorized as indoor, outdoor or indoor-outdoor (the latter representing samples collected in the malocas). The proportion of samples found positive for T. penetrans was lowest in the slum (9.3%) and highest in the Yanomami village (32.0%; P=0.01). Soil samples collected below bedsteads or hammocks or from the indoor resting places of dogs were significantly more likely to be positive than the indoor samples collected at other sites (65.0% v. 35.0%; P=0.02). There was no evidence indicating that the presence of T. penetrans in a soil sample was markedly affected by soil temperature, air temperature or air humidity. As no life stages of T. penetrans were found in any outdoor sample, it seems likely that, in resource-poor settings in Brazil, most transmission of T. penetrans occurs indoors. Control measures against the off-host life stages of T. penetrans should therefore be targeted at particular indoor micro-environments.

  15. Noble Gas signatures of Enhanced Oil Recovery

    NASA Astrophysics Data System (ADS)

    Barry, P. H.; Kulongoski, J. T.; Tyne, R. L.; Hillegonds, D.; Byrne, D. J.; Landon, M. K.; Ballentine, C. J.

    2017-12-01

    Noble gases are powerful tracers of fluids from various oil and gas production activities in hydrocarbon reservoirs and nearby groundwater. Non-radiogenic noble gases are introduced into undisturbed oil and natural gas reservoirs through exchange with formation waters [1-3]. Reservoirs with extensive hydraulic fracturing, injection for enhanced oil recovery (EOR), and/or waste disposal also show evidence for a component of noble gases introduced from air [4]. Isotopic and elemental ratios of noble gases can be used to 1) assess the migration history of the injected and formation fluids, and 2) determine the extent of exchange between multiphase fluids in different reservoirs. We present noble gas isotope and abundance data from casing, separator and injectate gases of the Lost Hills and Fruitvale oil fields in the San Joaquin basin, California. Samples were collected as part of the California State Water Resource Control Board's Oil and Gas Regional Groundwater Monitoring Program. Lost Hills (n=7) and Fruitvale (n=2) gases are geochemically distinct and duplicate samples are highly reproducible. Lost Hills casing gas samples were collected from areas where EOR and hydraulic fracturing has occurred in the past several years, and from areas where EOR is absent. The Fruitvale samples were collected from a re-injection port. All samples are radiogenic in their He isotopes, typical of a crustal environment, and show enrichments in heavy noble gases, resulting from preferential adsorption on sediments. Fruitvale samples reflect air-like surface conditions, with higher air-derived noble gas concentrations. Lost Hills gases show a gradation from pristine crustal signatures - indicative of closed-system exchange with formation fluids - to strongly air-contaminated signatures in the EOR region. Pristine samples can be used to determine the extent of hydrocarbon exchange with fluids, whereas samples with excess air can be used to quantify the extent of EOR. Determining noble gas baseline values for pristine vs. recently modified (EOR, hydraulic fracturing) zones will be critical for interpreting the origin of any fugitive gases identified in nearby aquifers. [1] Ballentine et al., (1996) GCA, 60, 831-849 [2] Barry et al., (2016) GCA, 194, 291-309. [3] Barry et al., (2017) Geology, 45, 9. Darrah et al., (2014) PNAS 111, 39.

  16. Occupational exposure to acrylamide in closed system production plants: air levels and biomonitoring.

    PubMed

    Moorman, William J; Reutman, Susan S; Shaw, Peter B; Blade, Leo Michael; Marlow, David; Vesper, Hubert; Clark, John C; Schrader, Steven M

    2012-01-01

    The aim of this study was to evaluate biomarkers of acrylamide exposure, including hemoglobin adducts and urinary metabolites in acrylamide production workers. Biomarkers are integrated measures of the internal dose, and it is total acrylamide dose from all routes and sources that may present health risks. Workers from three companies were studied. Workers potentially exposed to acrylamide monomer wore personal breathing-zone air samplers. Air samples and surface-wipe samples were collected and analyzed for acrylamide. General-area air samples were collected in chemical processing units and control rooms. Hemoglobin adducts were isolated from ethylenediamine teraacetic acid (EDTA)-whole blood, and adducts of acrylamide and glycidamide, at the N-terminal valines of hemoglobin, were cleaved from the protein chain by use of a modified Edman reaction. Full work-shift, personal breathing zone, and general-area air samples were collected and analyzed for particulate and acrylamide monomer vapor. The highest general-area concentration of acrylamide vapor was 350 μg/cm(3) in monomer production. Personal breathing zone and general-area concentrations of acrylamide vapor were found to be highest in monomer production operations, and lower levels were in the polymer production operations. Adduct levels varied widely among workers, with the highest in workers in the monomer and polymer production areas. The acrylamide adduct range was 15-1884 pmol/g; glycidamide adducts ranged from 17.8 to 1376 p/mol/g. The highest acrylamide and glycidamide adduct levels were found among monomer production process operators. The primary urinary metabolite N-acetyl-S-(2-carbamoylethyl) cysteine (NACEC) ranged from the limit of detection to 15.4 μg/ml. Correlation of workplace exposure and sentinel health effects is needed to determine and control safe levels of exposure for regulatory standards.

  17. Potential contamination of shipboard air samples by diffusive emissions of PCBs and other organic pollutants: implications and solutions.

    PubMed

    Lohmann, Rainer; Jaward, Foday M; Durham, Louise; Barber, Jonathan L; Ockenden, Wendy; Jones, Kevin C; Bruhn, Regina; Lakaschus, Soenke; Dachs, Jordi; Booij, Kees

    2004-07-15

    Air samples were taken onboard the RRS Bransfield on an Atlantic cruise from the United Kingdom to Halley, Antarctica, from October to December 1998, with the aim of establishing PCB oceanic background air concentrations and assessing their latitudinal distribution. Great care was taken to minimize pre- and post-collection contamination of the samples, which was validated through stringent QA/QC procedures. However, there is evidence that onboard contamination of the air samples occurred,following insidious, diffusive emissions on the ship. Other data (for PCBs and other persistent organic pollutants (POPs)) and examples of shipboard contamination are presented. The implications of these findings for past and future studies of global POPs distribution are discussed. Recommendations are made to help critically appraise and minimize the problems of insidious/diffusive shipboard contamination.

  18. COLLOIDAL-FACILITATED TRANSPORT OF INORGANIC CONTAMINANTS IN GROUND WATER: PART I. SAMPLING CONSIDERATIONS

    EPA Science Inventory

    Investigations at Pinal Creek, Arizona, evaluated routine sampling procedures for determination of aqueous inorganic geochemistry and assessment of contaminant transport by colloidal mobility. Sampling variables included pump type and flow rate, collection under air or nitrogen,...

  19. ENVIRONMENTAL RADIOACTIVITY AT ARGONNE NATIONAL LABORATORY. Report for the Year 1958

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sedlet, J.

    1959-08-01

    Data are tabulated on the radioactive content of samples of surface water, lake and stream bottom silt, soil, plants, and air filters from the environs of the Argonne National Laboratory. Results are compared with those for similar samples collected from the area from 1952 through 1958. Fission prcduct activity from nuclear detocations was found in most samples from all locations. Fall-out activity was greatest during the spring and fall, and was particularly noticeable in air, precipitation, and plant samples. (For preceding period see ANL-5934.) (C.H.)

  20. Evaluation of methods for simultaneous collection and determination of nicotine and polynuclear aromatic hydrocarbons in indoor air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chuang, J.C.; Kuhlman, M.R.; Wilson, N.K.

    1990-01-01

    A study was performed to determine whether one sampling system and one analytical method can be used to measure both polynuclear aromatic hydrocarbons (PAH) and nicotine. The PAH collection efficiencies for both XAD-2 and XAD-4 adsorbents are very similar, but the nicotine collection efficiency was greater for XAD-4. The spiked perdeuterated PAH were retained well in both adsorbents after exposure to more than 300 cu m of air. A two-step Soxhlet extraction, dichloromethane followed by ethylacetate, was used to remove nicotine and PAH from XAD-4. The extract was analyzed by positive chemical ionization or electron impact gas chromatography/mass spectrometry (GC/MS)more » to determine nicotine and PAH. It is shown that one sampling system (quartz fiber filter and XAD-4 in series) and one analytical method (Soxhlet extraction and GC/MS) can be used to measure both nicotine and PAH in indoor air.« less

  1. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD USE OF THE MODIFIED AIR SENTINEL (UA-F-10.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the in-field use of the modified Air Sentinel. Samples collected with this Hi-Vol instrument were analyzed for atmospheric concentrations of target metals. This procedure was followed to ensure consistent data retrieval of air and dust ana...

  2. Analytical method validation for the determination of 2,3,3,3-tetrafluoropropene in air samples using gas chromatography with flame ionization detection.

    PubMed

    Mawn, Michael P; Kurtz, Kristine; Stahl, Deborah; Chalfant, Richard L; Koban, Mary E; Dawson, Barbara J

    2013-01-01

    A new low global warming refrigerant, 2,3,3,3-tetrafluoro propene, or HFO-1234yf, has been successfully evaluated for automotive air conditioning, and is also being evaluated for stationary refrigeration and air conditioning systems. Due to the advantageous environmental properties of HFO-1234yf versus HFC-134a, coupled with its similar physical properties and system performance, HFO-1234yf is also being evaluated to replace HFC-134a in refrigeration applications where neat HFC-134a is currently used. This study reports on the development and validation of a sampling and analytical method for the determination of HFO-1234yf in air. Different collection media were screened for desorption and simulated sampling efficiency with three-section (350/350/350 mg) Anasorb CSC showing the best results. Therefore, air samples were collected using two 3-section Anasorb CSC sorbent tubes in series at 0.02 L/min for up to 8 hr for sample volumes of up to 9.6 L. The sorbent tubes were extracted in methylene chloride, and analyzed by gas chromatography with flame ionization detection. The method was validated from 0.1× to 20× the target level of 0.5 ppm (2.3 mg/m(3)) for a 9.6 L air volume. Desorption efficiencies for HFO-1234yf were 88 to 109% for all replicates over the validation range with a mean overall recovery of 93%. Simulated sampling efficiencies ranged from 87 to 104% with a mean of 94%. No migration or breakthrough to the back tube was observed under the sampling conditions evaluated. HFO-1234yf samples showed acceptable storage stability on Anasorb CSC sorbent up to a period of 30 days when stored under ambient, refrigerated, or frozen temperature conditions.

  3. Improved Atmospheric Sampling of Hexavalent Chromium

    PubMed Central

    Torkmahalleh, Mehdi Amouei; Yu, Chang-Ho; Lin, Lin; Fan, Zhihua (Tina); Swift, Julie L.; Bonanno, Linda; Rasmussen, Don H.; Holsen, Thomas M.; Hopke, Philip K.

    2015-01-01

    Hexavalent chromium (Cr(VI)) and trivalent chromium (Cr(III)) are the primary chromium oxidation states found in ambient atmospheric particulate matter. While Cr(III) is relatively nontoxic, Cr(VI) is toxic and exposure to Cr(VI) may lead to cancer, nasal damage, asthma, bronchitis, and pneumonitis. Accurate measurement of the ambient Cr(VI) concentrations is an environmental challenge since Cr(VI) can be reduced to Cr(III) and vice versa during sampling. In the present study, a new Cr(VI) sampler (Clarkson sampler) was designed, constructed, and field tested to improve the sampling of Cr(VI) in ambient air. The new Clarkson Cr(VI) sampler was based on the concept that deliquescence during sampling leads to aqueous phase reactions. Thus, the relative humidity of the sampled air was reduced below the deliquescence relative humidity (DRH) of the ambient particles. The new sampler was operated to collect Total Suspended Particles (TSP), and compared side-by-side with the current National Air Toxics Trends Stations (NATTS) Cr(VI) sampler that is utilized in the United States Environmental Protection Agency (USEPA) air toxics monitoring program. Side-by-side field testing of the samplers occurred in Elizabeth, NJ during the winter and summer of 2012. The average recovery values of Cr(VI) spikes after 24 hour sampling intervals during summer and winter sampling were 57 and 72%, respectively, for the Clarkson sampler, while the corresponding average values for NATTS samplers were 46% for both summer and winter sampling, respectively. Preventing the ambient aerosol collected on the filters from deliquescing is a key to improving the sampling of Cr(VI). PMID:24344574

  4. Tritium and 14C concentrations in unsaturated-zone gases at test hole UZB-2, Amargosa Desert Research Site, 1994-98: A section in U.S. Geological Survey Toxic Substances Hydrology Program: Proceedings of the technical meeting, Charleston, South Carolina, March 8-12, 1999: Volume 3 (Part C) (WRI 99-4018C)>

    USGS Publications Warehouse

    Prudic, David E.; Striegl, Robert G.; Healy, Richard W.; Michel, Robert L.; Haas, Herbert; Morganwalp, David W.; Buxton, Herbert T.

    1999-01-01

    Tritium concentrations have been determined yearly since April 1994 from water-vapor samples collected at test hole UZB-2. The hole was drilled about 100 m (meters) south of the southwest corner of a commercial burial site for low-level radioactive wastes in September 1993. UZB-2 is equipped with ten 2.5-cm (centimeters) diameter air ports permanently installed in the unsaturated zone between the depths of 5.5 and 108.8 m below land surface. Depth to ground water is about 110 m. Additional sampling ports were driven by hand to depths of 0.5, 1.0 and 1.5 m in May 1997. Initial samples of water vapor collected in April 1994 showed elevated tritium concentrations of more than 100 TU (tritium units) from all 10 air ports, with a maximum concentration of 762±10 TU from an air port at a depth of 24.1 m. Subsequent tritium concentrations increased in all air ports, although tritium concentrations at depths of less than 34.1 m have remained relatively constant since July 1995. The largest observed increase in tritium has been at a depth of 47.9 m. There, tritium concentration has increased from 198±5 TU in April 1994 to 2,570±30 TU in June 1998. Large increases also have been measured in samples collected from air ports at depths of 106.4 and 108.8 m, just above the water table.During September and October 1998, carbon dioxide samples were collected from all ten air ports in UZB-2 and at a depth of 1.5 m, and analyzed for radioactive carbon-14 (14C). 14C concentrations are highest in air ports at depths less than 6 m where they exceed 2,000 pmc (percent modern carbon). Concentrations decrease rapidly in air ports at depth and are about 20 pmc below 94.2 m. However, at 47.9 meters, the 14C concentration is 205±1 pmc, which is 2 to 4 times higher than concentrations in air ports immediately above and below. This depth corresponds to the largest tritium increase in UZB-2. Concentrations of both tritium and 14C are greater than what could be expected from atmospheric fallout. The distribution of tritium and 14C likely represent a complex pattern of lateral and vertical transport through the unsaturated zone from buried wastes to UZB-2.

  5. Field Sampling Plan/Quality Assurance Project Plan Volume I of III

    EPA Pesticide Factsheets

    This document contains procedures related to the collection and analysis of soil, sediment, groundwater, surface water, air and biota samples at GE’s Pittsfield, Massachusetts facility and at other areas.

  6. Polybrominated diphenyl ether (PBDE) concentrations and resulting exposure in homes in California: relationships among passive air, surface wipe and dust concentrations, and temporal variability.

    PubMed

    Bennett, D H; Moran, R E; Wu, X May; Tulve, N S; Clifton, M S; Colón, M; Weathers, W; Sjödin, A; Jones, R; Hertz-Picciotto, I

    2015-04-01

    Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive air, floor and indoor window surface wipes, and dust samples (investigator collected using an HVS3 and vacuum cleaner) in each home. PentaBDE and BDE209 were detected in the majority of the dust samples and many floor wipe samples, but the detection in air and window wipe samples was relatively low. Concentrations of each PBDE congener in different indoor environmental media were moderately correlated, with correlation coefficients ranging between 0.42 and 0.68. Correlation coefficients with blood levels were up to 0.65 and varied between environmental media and age group. Both investigator-collected dust and floor wipes were correlated with serum levels for a wide range of congeners. These two sample types also had a relatively high fraction of samples with adequate mass for reliable quantification. In 42 homes, PBDE levels measured in the same environmental media in the same home 1 year apart were statistically correlated (correlation coefficients: 0.57-0.90), with the exception of BDE209 which was not well correlated longitudinally. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Stratospheric measurements of ozone-depleting substances and greenhouse gases using AirCores

    NASA Astrophysics Data System (ADS)

    Laube, Johannes; Leedham Elvidge, Emma; Kaiser, Jan; Sturges, Bill; Heikkinen, Pauli; Laurila, Tuomas; Hatakka, Juha; Kivi, Rigel; Chen, Huilin; Fraser, Paul; van der Veen, Carina; Röckmann, Thomas

    2017-04-01

    Retrieving air samples from the stratosphere has previously required aircraft or large balloons, both of which are expensive to operate. The novel "AirCore" technique (Karion et al., 2010) enables stratospheric sampling using weather balloons, which is much more cost effective. AirCores are long (up to 200 m) stainless steel tubes which are placed as a payload on a small balloon, can ascend to over 30 km and fill upon descent, collecting a vertical profile of the atmosphere. Retrieved volumes are much smaller though, which presents a challenge for trace gas analysis. To date, only the more abundant trace gases such as carnon dioxide (CO2) and methane (CH4) have been quantified in AirCores. Halogenated trace gases are also important greenhouse gases and many also deplete stratospheric ozone. Their concentrations are however much lower i.e. typically in the part per trillion (ppt) molar range. We here present the first stratospheric measurements of halocarbons in AirCores obtained using UEA's highly sensitive (detection limits of 0.01-0.1 ppt in 10 ml of air) gas chromatography mass spectrometry system. The analysed air originates from a Stratospheric Air Sub-sampler (Mrozek et al., 2016) which collects AirCore segments after the non-destructive CO2 and CH4 analysis. Successfully measured species include CFC-11, CFC-12, CFC-113, CFC-115, H-1211, H-1301, HCFC-22, HCFC-141b, HCFC-142b, HCFC-133a, and sulphur hexafluoride (SF6). We compare the observed mixing ratios and precisions with data obtained from samples collected during various high-altitude aircraft campaigns between 2009 and 2016 as well as with southern hemisphere tropospheric long-term trends. As part of the ERC-funded EXC3ITE (EXploring stratospheric Composition, Chemistry and Circulation with Innovative Techniques) project more than 40 AirCore flights are planned in the next 3 years with an expanded range of up to 30 gases in order to explore seasonal and interannual variability in the stratosphere. References Karion et al., J. Atmos. Ocean. Technol., 27(11), 1839-1853, 2010 Mrozek et al., Atmos. Meas. Tech., 9, 5607-5620, 2016

  8. Detection of Mycoplasma hyopneumoniae by Air Sampling with a Nested PCR Assay

    PubMed Central

    Stärk, Katharina D. C.; Nicolet, Jacques; Frey, Joachim

    1998-01-01

    This article describes the first successful detection of airborne Mycoplasma hyopneumoniae under experimental and field conditions with a new nested PCR assay. Air was sampled with polyethersulfone membranes (pore size, 0.2 μm) mounted in filter holders. Filters were processed by dissolution and direct extraction of DNA for PCR analysis. For the PCR, two nested pairs of oligonucleotide primers were designed by using an M. hyopneumoniae-specific DNA sequence of a repeated gene segment. A nested PCR assay was developed and used to analyze samples collected in eight pig houses where respiratory problems had been common. Air was also sampled from a mycoplasma-free herd. The nested PCR was highly specific and 104 times as sensitive as a one-step PCR. Under field conditions, the sampling system was able to detect airborne M. hyopneumoniae on 80% of farms where acute respiratory disease was present. No airborne M. hyopneumoniae was detected on infected farms without acute cases. The chance of successful detection was increased if air was sampled at several locations within a room and at a lower air humidity. PMID:9464391

  9. Solid sorbent air sampling and analytical procedure for methyl-, dimethyl-, ethyl-, and diethylamine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elskamp, C.J.; Schultz, G.R.

    1986-01-01

    A sampling and analytical procedure for methyl-, dimethyl-, ethyl-, and diethylamine was developed in order to avoid problems typically encountered in the sampling and analysis of low molecular weight aliphatic amines. Samples are collected with adsorbent tubes containing Amberlite XAD-7 resin coated with the derivatizing reagent, NBD chloride (7-chloro-4-nitrobenzo-2-oxa-1,3-diazole). Analysis is performed by high performance liquid chromatography with the use of a fluorescence and/or UV/visible detector. All four amines can be monitored simultaneously, and neither collection nor storage is affected by humidity. Samples are stable at room temperature for at least two weeks. The methodology has been tested for eachmore » of the four amines at sample loadings equivalent to air concentration ranges of 0.5 to 30 ppm for a sample volume of 10 liters. The method shows promise for determining other airborne primary and secondary low molecular weight aliphatic amines.« less

  10. Construction and operation of a 10 cfm (cubic feet per minute) sampling system with a 10:1 dilution ratio for measuring condensable emissions. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steele, W.J.; Williamson, A.D.; McCain, J.D.

    1988-04-01

    The report describes a transportable sampling apparatus designed to sample incineration sources at municipal and hazardous-waste disposal facilities, and to provide non-contaminated samples of condensable materials. The sample gas, at a flow rate of 10 cubic feet per minute (c f/m), passes through a modified Source Assessment Sampling System (SASS) cyclone and is then diluted with clean air at 100 cf/m by a novel, perforated cone assembly. Rapid uniform dilution takes place through the vigorous mixing of the sample and clean air streams in the dilution chamber. The resultant gas, cooled to about atmospheric conditions, is passed through a mixingmore » section that provides a residence time of about 3 seconds. The resulting aerosol particles are collected on a Teflon-coated glass-fiber filter. These solids, along with those collected in the cyclone, are subsequently provided for chemical and biological assay analysis.« less

  11. HIGH SPEED GC/MS FOR AIR ANALYSIS

    EPA Science Inventory

    A high speed GC/MS system consisting of a gas chromatograph equipped with a narrow bandwidth injection accessory and using a time-of-flight mass spectrometer detector has been adapted for analysis of ambient whole air samples which have been collected in passivated canisters. ...

  12. Mercury concentrations and distribution in soil, water, mine waste leachates, and air in and around mercury mines in the Big Bend region, Texas, USA

    USGS Publications Warehouse

    Gray, John E.; Theodorakos, Peter M.; Fey, David L.; Krabbenhoft, David P.

    2015-01-01

    Samples of soil, water, mine waste leachates, soil gas, and air were collected from areas mined for mercury (Hg) and baseline sites in the Big Bend area, Texas, to evaluate potential Hg contamination in the region. Soil samples collected within 300 m of an inactive Hg mine contained elevated Hg concentrations (3.8–11 µg/g), which were considerably higher than Hg in soil collected from baseline sites (0.03–0.05 µg/g) distal (as much as 24 km) from mines. Only three soil samples collected within 300 m of the mine exceeded the probable effect concentration for Hg of 1.06 µg/g, above which harmful effects are likely to be observed in sediment-dwelling organisms. Concentrations of Hg in mine water runoff (7.9–14 ng/L) were generally higher than those found in springs and wells (0.05–3.1 ng/L), baseline streams (1.1–9.7 ng/L), and sources of drinking water (0.63–9.1 ng/L) collected in the Big Bend region. Concentrations of Hg in all water samples collected in this study were considerably below the 2,000 ng/L drinking water Hg guideline and the 770 ng/L guideline recommended by the U.S. Environmental Protection Agency (USEPA) to protect aquatic wildlife from chronic effects of Hg. Concentrations of Hg in water leachates obtained from leaching of mine wastes varied widely from <0.001 to 760 µg of Hg in leachate/g of sample leached, but only one leachate exceeded the USEPA Hg industrial soil screening level of 31 µg/g. Concentrations of Hg in soil gas collected at mined sites (690–82,000 ng/m3) were highly elevated compared to soil gas collected from baseline sites (1.2–77 ng/m3). However, air collected from mined areas at a height of 2 m above the ground surface contained concentrations of Hg (4.9–64 ng/m3) that were considerably lower than Hg in soil gas from the mined areas. Although concentrations of Hg emitted from mine-contaminated soils and mine wastes were elevated, persistent wind in southwest Texas disperses Hg in the air within a few meters of the ground surface.

  13. Volatile organic compounds: sampling methods and their worldwide profile in ambient air.

    PubMed

    Kumar, Anuj; Víden, Ivan

    2007-08-01

    The atmosphere is a particularly difficult analytical system because of the very low levels of substances to be analysed, sharp variations in pollutant levels with time and location, differences in wind, temperature and humidity. This makes the selection of an efficient sampling technique for air analysis a key step to reliable results. Generally, methods for volatile organic compounds sampling include collection of the whole air or preconcentration of samples on adsorbents. All the methods vary from each other according to the sampling technique, type of sorbent, method of extraction and identification technique. In this review paper we discuss various important aspects for sampling of volatile organic compounds by the widely used and advanced sampling methods. Characteristics of various adsorbents used for VOCs sampling are also described. Furthermore, this paper makes an effort to comprehensively review the concentration levels of volatile organic compounds along with the methodology used for analysis, in major cities of the world.

  14. Bias of Tedlar bags in the measurement of agricultural odorants.

    PubMed

    Trabue, Steven L; Anhalt, Jennifer C; Zahn, James A

    2006-01-01

    Odor regulations typically specify the use of dynamic dilution olfactometery (DDO) as a method to quantify odor emissions, and Tedlar bags are the preferred holding container for grab samples. This study was conducted to determine if Tedlar bags affect the integrity of sampled air from animal operations. Air samples were collected simultaneously in both Tedlar bags and Tenax thermal desorption tubes. Sample sources originated from either a hydrocarbon-free air tank, dynamic headspace chamber (DHC), or swine-production facility, and were analyzed by gas chromatography-mass spectrometry-olfactometry (GC-MS-O). Several background contaminants were identified from Tedlar bags, which included the odorous compounds N,N-dimethyl acetamide (DMAC), acetic acid, and phenol. Samples from the DHC demonstrated that recovery of malodor compounds was dependent on residence time in the Tedlar bag with longer residence time leading to lower recovery. After 24 h of storage, recovery of C3-C6 volatile fatty acids (VFA) averaged 64%, 4-methylphenol and 4-ethylphenol averaged 10%, and indole and 3-methylindole were below the detection limits of GC-MS-O. The odor activity value (OAV) of grab samples collected in Tedlar bags were 33 to 65% lower following 24 h of storage. These results indicate that significant odorant bias occurs when using Tedlar bags for the sampling of odors from animal production facilities.

  15. Comparison of Air Impaction and Electrostatic Dust Collector Sampling Methods to Assess Airborne Fungal Contamination in Public Buildings.

    PubMed

    Normand, Anne-Cécile; Ranque, Stéphane; Cassagne, Carole; Gaudart, Jean; Sallah, Kankoé; Charpin, Denis-André; Piarroux, Renaud

    2016-03-01

    Many ailments can be linked to exposure to indoor airborne fungus. However, obtaining a precise measurement of airborne fungal levels is complicated partly due to indoor air fluctuations and non-standardized techniques. Electrostatic dust collector (EDC) sampling devices have been used to measure a wide range of airborne analytes, including endotoxins, allergens, β-glucans, and microbial DNA in various indoor environments. In contrast, viable mold contamination has only been assessed in highly contaminated environments such as farms and archive buildings. This study aimed to assess the use of EDCs, compared with repeated air-impactor measurements, to assess airborne viable fungal flora in moderately contaminated indoor environments. Indoor airborne fungal flora was cultured from EDCs and daily air-impaction samples collected in an office building and a daycare center. The quantitative fungal measurements obtained using a single EDC significantly correlated with the cumulative measurement of nine daily air impactions. Both methods enabled the assessment of fungal exposure, although a few differences were observed between the detected fungal species and the relative quantity of each species. EDCs were also used over a 32-month period to monitor indoor airborne fungal flora in a hospital office building, which enabled us to assess the impact of outdoor events (e.g. ground excavations) on the fungal flora levels on the indoor environment. In conclusion, EDC-based measurements provided a relatively accurate profile of the viable airborne flora present during a sampling period. In particular, EDCs provided a more representative assessment of fungal levels compared with single air-impactor sampling. The EDC technique is also simpler than performing repetitive air-impaction measures over the course of several consecutive days. EDC is a versatile tool for collecting airborne samples and was efficient for measuring mold levels in indoor environments. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  16. Improvement of a wind-tunnel sampling system for odour and VOCs.

    PubMed

    Wang, X; Jiang, J; Kaye, R

    2001-01-01

    Wind-tunnel systems are widely used for collecting odour emission samples from surface area sources. Consequently, a portable wind-tunnel system was developed at the University of New South Wales that was easy to handle and suitable for sampling from liquid surfaces. Development work was undertaken to ensure even air-flows above the emitting surface and to optimise air velocities to simulate real situations. However, recovery efficiencies for emissions have not previously been studied for wind-tunnel systems. A series of experiments was carried out for determining and improving the recovery rate of the wind-tunnel sampling system by using carbon monoxide as a tracer gas. It was observed by mass balance that carbon monoxide recovery rates were initially only 37% to 48% from a simulated surface area emission source. It was therefore apparent that further development work was required to improve recovery efficiencies. By analysing the aerodynamic character of air movement and CO transportation inside the wind-tunnel, it was determined that the apparent poor recoveries resulted from uneven mixing at the sample collection point. A number of modifications were made for the mixing chamber of the wind-tunnel system. A special sampling chamber extension and a sampling manifold with optimally distributed sampling orifices were developed for the wind-tunnel sampling system. The simulation experiments were repeated with the new sampling system. Over a series of experiments, the recovery efficiency of sampling was improved to 83-100% with an average of 90%, where the CO tracer gas was introduced at a single point and 92-102% with an average of 97%, where the CO tracer gas was introduced along a line transverse to the sweep air. The stability and accuracy of the new system were determined statistically and are reported.

  17. CTEPP NC DATA SUPPLEMENTAL INFORMATION ON FIELD AND LABORATORY SAMPLES

    EPA Science Inventory

    This data set contains supplemental data related to the final core analytical results table. This includes sample collection data for example sample weight, air volume, creatinine, specific gravity etc.

    The Children’s Total Exposure to Persistent Pesticides and Other Persistent...

  18. Impacts of roadway emissions on urban particulate matter concentrations in sub-Saharan Africa: new evidence from Nairobi, Kenya

    NASA Astrophysics Data System (ADS)

    van Vliet, E. D. S.; Kinney, P. L.

    2007-10-01

    Air quality is a serious and worsening problem in the rapidly growing cities of sub-Saharan Africa (SSA). However, the lack of ambient monitoring data, and particularly urban roadside concentrations for particulate matter in SSA cities severely hinders our ability to describe temporal and spatial patterns of concentrations, characterize exposure response relationships for key health outcomes, estimate disease burdens, and promote policy initiatives to address air quality. As part of a collaborative transportation planning exercise between Columbia University and the University of Nairobi, air monitoring was carried out in February 2006 in Nairobi, Kenya. The objective of the monitoring was to collect pilot data on air concentrations (PM2.5 and black carbon) encountered while driving in the Nairobi metropolitan area, and to compare those data to simultaneous 'urban background' concentrations measured in Nairobi but away from roadways. For both the background and roadway monitoring, we used portable air sampling systems that collect integrated filter samples. Results from this pilot study found that roadway concentrations of PM2.5 were approximately 20-fold higher than those from the urban background site, whereas black carbon concentrations differed by 10-fold. If confirmed by more extensive sampling, these data would underscore the need for air quality and transportation planning and management directed at mitigating roadway pollution.

  19. Subsurface sediment contamination during borehole drilling with an air-actuated down-hole hammer.

    PubMed

    Malard, Florian; Datry, Thibault; Gibert, Janine

    2005-10-01

    Drilling methods can severely alter physical, chemical, and biological properties of aquifers, thereby influencing the reliability of water samples collected from groundwater monitoring wells. Because of their fast drilling rate, air-actuated hammers are increasingly used for the installation of groundwater monitoring wells in unconsolidated sediments. However, oil entrained in the air stream to lubricate the hammer-actuating device can contaminate subsurface sediments. Concentrations of total hydrocarbons, heavy metals (Cu, Ni, Cr, Zn, Pb, and Cd), and nutrients (particulate organic carbon, nitrogen, and phosphorus) were measured in continuous sediment cores recovered during the completion of a 26-m deep borehole drilled with a down-hole hammer in glaciofluvial deposits. Total hydrocarbons, Cu, Ni, Cr and particulate organic carbon (POC) were all measured at concentrations far exceeding background levels in most sediment cores. Hydrocarbon concentration averaged 124 +/- 118 mg kg(-1) dry sediment (n = 78 samples) with peaks at depths of 8, 14, and 20 m below the soil surface (maximum concentration: 606 mg kg(-1)). The concentrations of hydrocarbons, Cu, Ni, Cr, and POC were positively correlated and exhibited a highly irregular vertical pattern, that probably reflected variations in air loss within glaciofluvial deposits during drilling. Because the penetration of contaminated air into the formation is unpreventable, the representativeness of groundwater samples collected may be questioned. It is concluded that air percussion drilling has strong limitations for well installation in groundwater quality monitoring surveys.

  20. Collecting apparatus

    DOEpatents

    Duncan, Charles P.

    1983-01-01

    An improved collecting apparatus for small aquatic or airborne organisms such as plankton, larval fish, insects, etc. The improvement constitutes an apertured removal container within which is retained a collecting bag, and which is secured at the apex of a conical collecting net. Such collectors are towed behind a vessel or vehicle with the open end of the conical net facing forward for trapping the aquatic or airborne organisms within the collecting bag, while allowing the water or air to pass through the apertures in the container. The container is readily removable from the collecting net whereby the collecting bag can be quickly removed and replaced for further sample collection. The collecting bag is provided with means for preventing the bag from being pulled into the container by the water or air flowing therethrough.

  1. CONTROLLED METHYL TERTIARY BUTYL ETHER (MTBE) EXPOSURE TO HUMANS THROUGH DERMAL, INGESTION, AND INHALATION ROUTES AND THE RESULTANT BIOMARKER TERTIARY BUTYL ALCOHOL (TBA) AS MEASURED IN EXHALED BREATH AND VENOUS BLOOD

    EPA Science Inventory

    Radiocarbon (14C) measurements provide an estimate of the fraction of carbon in a sample that is biogenic. In September 1997 during SCOS97 a series of 3-h canister samples of ambient air were collected at the Azusa air monitoring station during morning and afternoon periods. ...

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, R.; Engel, A.; Franken, H.

    This paper describes balloon borne air samples taken above Kiruna (67.9[degrees]N; 21.1[degrees]E) during EASOE, which monitored the N[sub 2]O density, as the polar vortex shifted, between altitudes of 10 and 31 km. Different air samplers were used to collect samples. The results show vertical profiles, outside, in the edge of, and inside the vertex, which reveal variation in mixing ratios as airmasses mix both vertically and horizontally near the vortex.

  3. Influence of tap water quality and household water use activities on indoor air and internal dose levels of trihalomethanes.

    PubMed

    Nuckols, John R; Ashley, David L; Lyu, Christopher; Gordon, Sydney M; Hinckley, Alison F; Singer, Philip

    2005-07-01

    Individual exposure to trihalomethanes (THMs) in tap water can occur through ingestion, inhalation, or dermal exposure. Studies indicate that activities associated with inhaled or dermal exposure routes result in a greater increase in blood THM concentration than does ingestion. We measured blood and exhaled air concentrations of THM as biomarkers of exposure to participants conducting 14 common household water use activities, including ingestion of hot and cold tap water beverages, showering, clothes washing, hand washing, bathing, dish washing, and indirect shower exposure. We conducted our study at a single residence in each of two water utility service areas, one with relatively high and the other low total THM in the residence tap water. To maintain a consistent exposure environment for seven participants, we controlled water use activities, exposure time, air exchange, water flow and temperature, and nonstudy THM sources to the indoor air. We collected reference samples for water supply and air (pre-water use activity), as well as tap water and ambient air samples. We collected blood samples before and after each activity and exhaled breath samples at baseline and post-activity. All hot water use activities yielded a 2-fold increase in blood or breath THM concentrations for at least one individual. The greatest observed increase in blood and exhaled breath THM concentration in any participant was due to showering (direct and indirect), bathing, and hand dishwashing. Average increase in blood THM concentration ranged from 57 to 358 pg/mL due to these activities. More research is needed to determine whether acute and frequent exposures to THM at these concentrations have public health implications. Further research is also needed in designing epidemiologic studies that minimize data collection burden yet maximize accuracy in classification of dermal and inhalation THM exposure during hot water use activities.

  4. Influence of Tap Water Quality and Household Water Use Activities on Indoor Air and Internal Dose Levels of Trihalomethanes

    PubMed Central

    Nuckols, John R.; Ashley, David L.; Lyu, Christopher; Gordon, Sydney M.; Hinckley, Alison F.; Singer, Philip

    2005-01-01

    Individual exposure to trihalomethanes (THMs) in tap water can occur through ingestion, inhalation, or dermal exposure. Studies indicate that activities associated with inhaled or dermal exposure routes result in a greater increase in blood THM concentration than does ingestion. We measured blood and exhaled air concentrations of THM as biomarkers of exposure to participants conducting 14 common household water use activities, including ingestion of hot and cold tap water beverages, showering, clothes washing, hand washing, bathing, dish washing, and indirect shower exposure. We conducted our study at a single residence in each of two water utility service areas, one with relatively high and the other low total THM in the residence tap water. To maintain a consistent exposure environment for seven participants, we controlled water use activities, exposure time, air exchange, water flow and temperature, and nonstudy THM sources to the indoor air. We collected reference samples for water supply and air (pre–water use activity), as well as tap water and ambient air samples. We collected blood samples before and after each activity and exhaled breath samples at baseline and postactivity. All hot water use activities yielded a 2-fold increase in blood or breath THM concentrations for at least one individual. The greatest observed increase in blood and exhaled breath THM concentration in any participant was due to showering (direct and indirect), bathing, and hand dishwashing. Average increase in blood THM concentration ranged from 57 to 358 pg/mL due to these activities. More research is needed to determine whether acute and frequent exposures to THM at these concentrations have public health implications. Further research is also needed in designing epidemiologic studies that minimize data collection burden yet maximize accuracy in classification of dermal and inhalation THM exposure during hot water use activities. PMID:16002374

  5. NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR VOCS IN BLANKS

    EPA Science Inventory

    This data set includes analytical results for measurements of VOCs in 88 blank samples. Measurements were made for up to 23 VOCs in blank samples of air, water, and blood. Blank samples were used to assess the potential for sample contamination during collection, storage, shipmen...

  6. Indoor air condensate as a novel matrix for monitoring inhalable organic contaminants.

    PubMed

    Roll, Isaac B; Halden, Rolf U; Pycke, Benny F G

    2015-05-15

    With the population of developed nations spending nearly 90% of their time indoors, indoor air quality (IAQ) is a critical indicator of human health risks from inhalation of airborne contaminants. We present a novel approach for qualitative monitoring of IAQ through the collection and analysis of indoor air condensate discharged from heat exchangers of heating, ventilation, and air conditioning (HVAC) systems. Condensate samples were collected from six suburban homes and one business in Maricopa County, Arizona, concentrated via solid-phase extraction, analyzed for 10 endocrine disrupting chemicals (EDCs) by liquid chromatography-tandem mass spectrometry (LC-MS/MS), and screened for additional organic compounds by gas chromatography-mass spectrometry (GC-MS). All 10 EDCs were detected in at least one of the sampled buildings. More than 100 additional compounds were detected by GC-MS, of which 40 were tentatively identified using spectral database searches. Twelve compounds listed as designated chemicals for biomonitoring by the California Environmental Contaminant Biomonitoring Program were detected. Microfiltration of condensate samples prior to extraction had no discernable effect on contaminant concentration, suggesting that contaminants were freely dissolved or associated with inhalable, submicron particles. This study is the first to document the utility of HVAC condensate for the qualitative assessment of indoor air for pollutants. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Microbial quality of water in dental unit waterlines.

    PubMed

    Nikaeen, Mahnaz; Hatamzadeh, Maryam; Sabzevari, Zohre; Zareh, Omolbanin

    2009-09-01

    Dental unit waterlines (DUWLs) are ideal environment for development of microbial biofilms. Microbial contamination of water in DUWLs is thought to be the result of biofilm formation as it could serves as a haven for pathogens. The aim of this study was to assess microbial quality of water in dental unit waterlines of dental units located at the dental school of Isfahan University of Medical Sciences. Water samples were collected from air/water syringe and high-speed handpiece. Generally, 100-200 ml water samples were collected aseptically in sterile containers with sodium thiosulfate at the beginning of the day after a 2 minute purge. Samples were transferred to the laboratory in insulated box with cooling packs and examined for total viable heterotrophic bacteria and fungi. The heterotrophic plate count levels were significantly exceeded the American Dental Association recommendations for DUWL water quality (< 200 CFU/ml), in both air/water syringe (84%, CFU/ml: 500-20000) and high-speed handpiece (96%, CFU/ml: 710-36800) samples. However, there was no significant difference between the level of contamination in the air/water syringe and high-speed handpiece. Fungi were found in 28% and 36% of air/water syringe and high-speed handpiece samples, respectively; and filamentous fungi were the most frequently isolated fungi. DUWLs should be subjected to routine microbial monitoring and to a decontamination protocol in order to minimize the risk of exposure to potential pathogens from dental units.

  8. Device and method for accurately measuring concentrations of airborne transuranic isotopes

    DOEpatents

    McIsaac, Charles V.; Killian, E. Wayne; Grafwallner, Ervin G.; Kynaston, Ronnie L.; Johnson, Larry O.; Randolph, Peter D.

    1996-01-01

    An alpha continuous air monitor (CAM) with two silicon alpha detectors and three sample collection filters is described. This alpha CAM design provides continuous sampling and also measures the cumulative transuranic (TRU), i.e., plutonium and americium, activity on the filter, and thus provides a more accurate measurement of airborne TRU concentrations than can be accomplished using a single fixed sample collection filter and a single silicon alpha detector.

  9. Device and method for accurately measuring concentrations of airborne transuranic isotopes

    DOEpatents

    McIsaac, C.V.; Killian, E.W.; Grafwallner, E.G.; Kynaston, R.L.; Johnson, L.O.; Randolph, P.D.

    1996-09-03

    An alpha continuous air monitor (CAM) with two silicon alpha detectors and three sample collection filters is described. This alpha CAM design provides continuous sampling and also measures the cumulative transuranic (TRU), i.e., plutonium and americium, activity on the filter, and thus provides a more accurate measurement of airborne TRU concentrations than can be accomplished using a single fixed sample collection filter and a single silicon alpha detector. 7 figs.

  10. California GAMA Special Study. Development of a Capability for the Analysis of Krypton-85 in Groundwater Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Visser, Ate; Bibby, Richard K.; Moran, Jean E.

    A capability for the analysis of krypton-85 ( 85Kr) in groundwater samples was developed at LLNL. Samples are collected by extracting gas from 2000-4000 L of groundwater at the well, yielding approximately 0.2 cm 3 STP krypton. Sample collection takes 1 to 4 hours. Krypton is purified in the laboratory using a combination of molecular sieve and activated charcoal traps, and transferred to a liquid scintillation vial. The 85Kr activity is measured by liquid scintillation on a Quantulus 1220 liquid scintillation counter from PerkinElmer. The detection limit for a typical 0.2 cm 3Kr sample size is 11% of the presentmore » day activity in air, corresponding to the decay corrected activity in air in 1987. The typical measurement uncertainty is below 10% for recently recharged samples. Six groundwater samples were collected, purified and counted. 85Kr was not detected in any of the samples counted at LLNL. 85Kr was detected by the low level counting laboratory of Bern University in all samples between 1.5 and 6.6 decays per minute per cm 3 krypton, corresponding to decay corrected activities in air between 1971 and 1985. The new capability is an excellent complement to tritium-helium, expanding the existing suite of age dating tools available to the GAMA program ( 35S, 3H/ 3He, 14C and radiogenic helium). 85Kr can replace 3H/ 3He in settings where 3H/ 3He ages are impossible to determine (for example where terrigenic helium overwhelms tritiogenic helium) and provides additional insight into travel time distributions in complex mixed groundwater systems.« less

  11. Murine norovirus detection in the exhaust air of IVCs is more sensitive than serological analysis of soiled bedding sentinels.

    PubMed

    Zorn, Julia; Ritter, Bärbel; Miller, Manuel; Kraus, Monika; Northrup, Emily; Brielmeier, Markus

    2017-06-01

    One limitation to housing rodents in individually ventilated cages (IVCs) is the ineffectiveness of traditional health monitoring programs that test soiled bedding sentinels every quarter. Aerogen transmission does not occur with this method. Moreover, the transmission of numerous pathogens in bedding is uncertain, and sentinel susceptibility to various pathogens varies. A novel method using particle collection from samples of exhaust air was developed in this study which was also systematically compared with routine health monitoring using soiled bedding sentinels. We used our method to screen these samples for the presence of murine norovirus (MNV), a mouse pathogen highly prevalent in laboratory animal facilities. Exhaust air particles from prefilters of IVC racks with known MNV prevalence were tested by quantitative reverse transcription polymerase chain reaction (RT-qPCR). MNV was detected in exhaust air as early as one week with one MNV-positive cage per rack, while sentinels discharged MNV RNA without seroconverting. MNV was reliably and repeatedly detected in particles collected from samples of exhaust air in all seven of the three-month sampling rounds, with increasing MNV prevalence, while sentinels only seroconverted in one round. Under field conditions, routine soiled bedding sentinel health monitoring in our animal facility failed to identify 67% ( n = 85) of positive samples by RT-qPCR of exhaust air particles. Thus, this method proved to be highly sensitive and superior to soiled bedding sentinels in the reliable detection of MNV. These results represent a major breakthrough in hygiene monitoring of rodent IVC systems and contribute to the 3R principles by reducing the number of animals used and by improving experimental conditions.

  12. Research and development of a field-ready protocol for sampling of phosgene from stationary source emissions: Diethylamine reagent studies. Research report, 11 July 1995--30 September 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steger, J.L.; Bursey, J.T.; Merrill, R.G.

    1999-03-01

    This report presents the results of laboratory studies to develop and evaluate a method for the sampling and analysis of phosgene from stationary sources of air emissions using diethylamine (DEA) in toluene as the collection media. The method extracts stack gas from emission sources and stabilizes the reactive gas for subsequent analysis. DEA was evaluated both in a benchtop study and in a laboratory train spiking study. This report includes results for both the benchtop study and the train spiking study. Benchtop studies to evaluate the suitability of DEA for collecting and analyzing phosgene investigated five variables: storage time, DEAmore » concentration, moisture/pH, phosgene concentration, and sample storage temperature. Prototype sampling train studies were performed to determine if the benchtop chemical studies were transferable to a Modified Method 5 sampling train collecting phosgene in the presence of clean air mixed with typical stack gas components. Four conditions, which varied the moisture and phosgene spike were evaluated in triplicate. In addition to research results, the report includes a detailed draft method for sampling and analysis of phosgene from stationary source emissions.« less

  13. In situ Carbon 13 and Oxygen 18 Ratios of Atmospheric CO2 from Cape Grim\\, Tasmania\\, Australia,1982-1993 (DB1014)

    DOE Data Explorer

    Francey, R. J. [CSIRO Division of Atmospheric Research, Mordialloc, Victoria, Australia; Allison, C. E. [CSIRO Division of Atmospheric Research, Mordialloc, Victoria, Australia

    1998-01-01

    Since 1982, a continuous program of sampling atmospheric CO2 to determine stable isotope ratios has been maintained at the Australian Baseline Air Pollution Station, Cape Grim, Tasmania (40°, 40'56"S, 144°, 41'18"E). The process of in situ extraction of CO2 from air, the preponderance of samples collected in conditions of strong wind from the marine boundary layer of the Southern Ocean, and the determination of all isotope ratios relative to a common high purity CO2 reference gas with isotopic δ13C close to atmospheric values, are a unique combination of factors with respect to obtaining a globally representative signal from a surface site. Air samples are collected during baseline condition episodes at a frequency of around one sample per week. Baseline conditions are characterized by wind direction in the sector 190°-280°, condensation nucleus concentration below 600 per cm-3, and steady continuous CO2 concentrations (variation ± 0.2 ppmv per hour). A vacuum pump draws air from either the 10 m or 70 m intakes and sampling alternates between the two intakes. The air from the intake is dried with a trap immersed in an alcohol bath at about -80°C. Mass spectrometer analyses for δ13C and δ18O are carried out by CSIRO's Division of Atmospheric Research in Aspendale, usually one to three weeks following collection. This record is possibly the most accurate representation of global atmospheric 13C behavior over the last decade and may be used to partition the uptake of fossil-fuel carbon emissions between ocean and terrestrial plant reservoirs. Using these data, Francey et al. (1995) observed a gradual decrease in δ13C from 1982 to 1993, but with a pronounced flattening from 1988 to 1990; a trend that appears to involve the terrestrial carbon cycle.

  14. Determination and comparison of microbial loads in atmospheres of two hospitals in Izmir, Turkey.

    PubMed

    Aydin Çakir, Nergüze; Uçar, Füsun Bahriye; Haliki Uztan, Alev; Corbaci, Cengiz; Akpinar, Onur

    2013-01-01

    Nosocomial infections, also known as hospital-acquired infections, has become one of the most important health problems in health care units worldwide. The presented study aims to determine the average amount of microorganism loads and to show that the atmospheres of the two hospitals can be a potential source regarding nosocomial infections. The effect of surface and floor disinfection processes in the two hospitals and the antibiotic susceptibility of the bacterial isolates were also evaluated. Microorganisms were isolated from air samples collected from different areas (patient wards, corridors, operating theatres and postoperative units) of the two hospitals in Izmir. Sampling was conducted between December 2006 - March 2007. During the 3-month sampling period, the average number of live microorganisms in the air samples collected from second-class environments in the hospital 1 and the hospital 2 was found to be 224.44 and 536.66 cfu/m(3) , respectively. The average number of microorganisms in hospital 2 collected before the disinfection process was higher than those after the disinfection process. However, because of the closure of the air-conditioning system and the hepa filters after the disinfection process, this was reversed in hospital 1. In total, 54 and 42 isolates were obtained from hospital 1 and hospital 2, respectively. 49 isolates from hospital 1 and 35 isolates from hospital 2 were identified as Staphylacoccus sp. The remaining isolates were identified as Aerococcus sp. and Enterococcus sp. Pseudomonas sp. was not determined in the air samples of the two hospitals. It was detected that the microbial loads in the atmospheres of the two hospitals studied varied greatly depending on the number of people in the environment. As the results indicate, the total number of microorganisms in the atmospheres of operating theatres in both hospitals does not pose a threat according to the Air Microbe Index.

  15. Improved particle impactor assembly for size selective high volume air sampler

    DOEpatents

    Langer, G.

    1987-03-23

    Air containing entrained particulate matter is directed through a plurality of parallel, narrow, vertically oriented apertures of an inlet element toward an adjacently located, relatively large, dust impaction surface preferably covered with an adhesive material. The air flow turns over the impaction surface, leaving behind, the relatively larger particles and passes through two elongate apertures defining the outer bounds of the impaction collection surface to pass through divergent passages which slow down and distribute the air flow, with entrained smaller particles, over a fine filter element that separates the fine particles from the air. By appropriate selection of dimensions and the number of inlet apertures air flow through the inlet element is provided a nonuniform velocity distribution with the lower velocities being obtained near the center of the inlet apertures, to separate out particles larger than a certain predetermined size on the impaction collection surface. The impaction collection surface, even in a moderately sized apparatus, is thus relatively large and permits the prolonged sampling of air for periods extending to four weeks. 6 figs.

  16. Aerosol Sampling Experiment on the International Space Station

    NASA Technical Reports Server (NTRS)

    Meyer, Marit E.

    2017-01-01

    The International Space Station (ISS) is a unique indoor environment which serves as both home and workplace to the astronaut crew. There is currently no particulate monitoring, although particulate matter requirements exist. An experiment to collect particles in the ISS cabin was conducted recently. Two different aerosol samplers were used for redundancy and to collect particles in two size ranges spanning from 10 nm to hundreds of micrometers. The Active Sampler is a battery operated thermophoretic sampler with an internal pump which draws in air and collects particles directly on a transmission electron microscope grid. This commercial-off-the-shelf device was modified for operation in low gravity. The Passive Sampler has five sampling surfaces which were exposed to air for different durations in order to collect at least one sample with an optimal quantity of particles for microscopy. These samples were returned to Earth for analysis with a variety of techniques to obtain long-term average concentrations and identify particle emission sources. Results are compared with the inventory of ISS aerosols which was created based on sparse data and the literature. The goal of the experiment is to obtain data on indoor aerosols on ISS for future particulate monitor design and development.

  17. AIR EMISSIONS FROM COMBUSTION OF SOLVENT REFINED COAL

    EPA Science Inventory

    The report gives details of a Solvent Refined Coal (SRC) combustion test at Georgia Power Company's Plant Mitchell, March, May, and June 1977. Flue gas samples were collected for modified EPA Level 1 analysis; analytical results are reported. Air emissions from the combustion of ...

  18. DEVELOPMENT, EVALUATION AND APPLICATION OF AN AUTOMATED EVENT PRECIPITATION SAMPLER FOR NETWORK OPERATION

    EPA Science Inventory

    In 1993, the University of Michigan Air Quality Laboratory (UMAQL) designed a new wet-only precipitation collection system that was utilized in the Lake Michigan Loading Study. The collection system was designed to collect discrete mercury and trace element samples on an event b...

  19. Environmental sampling and analysis in support of NTI-3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGuire, R.R.; Harrar, J.E.; Haas, J.S.

    1991-04-06

    The third National Trail Inspection took place at the Monsanto Chemical Plant in Luling, Louisiana. In order to test the effectiveness of environmental sampling (soil, water and air) in determining the nature of the chemical process in a given production plant and to examine the distance from a process building that samples can effectively be taken, we needed to select some materials that constituted components of process streams. Three materials were selected: 1. isopropyl amine for air monitoring, 2. 4-nitrophenol, one of the precursors in the acetaminophen process, and 3. an intermediate in the production of glyphosate for ROUNDUP thatmore » is known simply as glyphosate intermediated. LLNL did not participate in the air sampling nor the analysis for isopropyl amine. This paper discussed the steps in this experiment including sample collection, sample workshop, sample analysis the results and discussion and the conclusion. 3 figs., 6 tabs.« less

  20. Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEMPLETON, A.M.

    2000-03-06

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissionsmore » Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.« less

  1. Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEMPLETON, A.M.

    2000-01-31

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissionsmore » Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.« less

  2. Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEMPLETON, A.M.

    2000-04-10

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissionsmore » Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.« less

  3. Personal exposure to volatile organic compounds. I. Direct measurements in breathing-zone air, drinking water, food, and exhaled breath

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallace, L.A.; Pellizzari, E.; Hartwell, T.

    A pilot study to test methods of estimating personal exposures to toxic substances and corresponding body burdens was carried out between July and December 1980. Individual exposures to about a dozen volatile organic compounds in air and drinking water were measured for volunteers in New Jersey and North Carolina. Breath samples were also collected from all subjects. About 230 personal air samples, 170 drinking water samples, 66 breath samples, and 4 food samples (16 composites) were analyzed for the target chemicals. Ten compounds were present in air and eight were transmitted mainly through that medium. Chloroform and bromodichloromethane were predominantlymore » transmitted through water and beverages. Food appeared to be a miner route of exposure, except possibly for trichloroethylene in margarine. Seven compounds were present in more than half of the breath samples. Diurnal and seasonal variations were noted in air and water concentrations of some compounds. Some, but not all, of the potentially occupationally exposed individuals had significantly higher workplace exposures to several chemicals. Distributions of air exposures were closer to log normal than normal for most chemicals. Several chemicals were highly correlated with each other in personal air samples, indicating possible common sources of exposures. Compounds detected included benzene, chlorinated aromatic hydrocarbons, chlorinated aliphatic hydrocarbons, halogens and vinyl chloride.« less

  4. BP Spill Sampling and Monitoring Data

    EPA Pesticide Factsheets

    This dataset analyzes waste from the the British Petroleum Deepwater Horizon Rig Explosion Emergency Response, providing opportunity to query data sets by metadata criteria and find resulting raw datasets in CSV format.The data query tool allows users to download EPA's air, water and sediment sampling and monitoring data that has been collected in response to the BP oil spill. All sampling and monitoring data that has been collected to date is available for download as raw structured data.The query tools enables CSV file creation to be refined based on the following search criteria: date range (between April 28, 2010 and 9/29/2010); location by zip, city, or county; media (solid waste, weathered oil, air, surface water, liquid waste, tar, sediment, water); substance categories (based on media selection) and substances (based on substance category selection).

  5. Convair F-106B Delta Dart with Air Sampling Equipment

    NASA Image and Video Library

    1974-04-21

    The National Aeronautics and Space Administration (NASA) Lewis Research Center’s Convair F-106B Delta Dart equipped with air sampling equipment in the mid-1970s. NASA Lewis created and managed the Global Air Sampling Program (GASP) in 1972 in partnership with several airline companies. NASA researchers used the airliners’ Boeing 747 aircraft to gather air samples to determine the amount of pollution present in the stratosphere. Private companies developed the air sampling equipment for the GASP program, and Lewis created a particle collector. The collector was flight tested on NASA Lewis’ F-106B in the summer of 1973. The sampling equipment was automatically operated once the proper altitude was achieved. The sampling instruments collected dust particles in the air so their chemical composition could be analyzed. The equipment analyzed one second’s worth of data at a time. The researchers also monitored carbon monoxide, monozide, ozone, and water vapor. The 747 flights began in December 1974 and soon included four airlines flying routes all over the globe. The F-106B augmented the airline data with sampling of its own, seen here. It gathered samples throughout this period from locations such as New Mexico, Texas, Michigan, and Ohio. In July 1977 the F-106B flew eight GASP flights in nine days over Alaska to supplement the earlier data gathered by the airlines.

  6. A Comparison Study of Sampling and Analyzing Volatile Organic Compounds in Air in Kuwait by Using Tedlar Bags/Canisters and GC-MS with a Cryogenic Trap

    PubMed Central

    Tang, Hongmao; Beg, Khaliq R.; Al-Otaiba, Yousef

    2006-01-01

    Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results. PMID:16699723

  7. A comparison study of sampling and analyzing volatile organic compounds in air in Kuwait by using Tedlar bags/canisters and GC-MS with a cryogenic trap.

    PubMed

    Tang, Hongmao; Beg, Khaliq R; Al-Otaiba, Yousef

    2006-05-12

    Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results.

  8. CTEPP-OH DATA SUPPLEMENTAL INFORMATION ON FIELD AND LABORATORY SAMPLES

    EPA Science Inventory

    This data set contains supplemental data related to the final core analytical results table for CTEPP-OH. This includes sample collection data for example sample weight, air volume, creatinine, specific gravity etc.

    The Children’s Total Exposure to Persistent Pesticides and Oth...

  9. Analytical instrument with apparatus and method for sample concentrating

    DOEpatents

    Zaromb, S.

    1986-08-04

    A system for analysis of trace concentrations of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.

  10. Analytical instrument with apparatus for sample concentrating

    DOEpatents

    Zaromb, Solomon

    1989-01-01

    A system for analysis of trace concentrations of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.

  11. Method for preconcentrating a sample for subsequent analysis

    DOEpatents

    Zaromb, Solomon

    1990-01-01

    A system for analysis of trace concentration of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.

  12. Detection of airborne Stachybotrys chartarum macrocyclic trichothecene mycotoxins in the indoor environment.

    PubMed

    Brasel, T L; Martin, J M; Carriker, C G; Wilson, S C; Straus, D C

    2005-11-01

    The existence of airborne mycotoxins in mold-contaminated buildings has long been hypothesized to be a potential occupant health risk. However, little work has been done to demonstrate the presence of these compounds in such environments. The presence of airborne macrocyclic trichothecene mycotoxins in indoor environments with known Stachybotrys chartarum contamination was therefore investigated. In seven buildings, air was collected using a high-volume liquid impaction bioaerosol sampler (SpinCon PAS 450-10) under static or disturbed conditions. An additional building was sampled using an Andersen GPS-1 PUF sampler modified to separate and collect particulates smaller than conidia. Four control buildings (i.e., no detectable S. chartarum growth or history of water damage) and outdoor air were also tested. Samples were analyzed using a macrocyclic trichothecene-specific enzyme-linked immunosorbent assay (ELISA). ELISA specificity was tested using phosphate-buffered saline extracts of the fungal genera Aspergillus, Chaetomium, Cladosporium, Fusarium, Memnoniella, Penicillium, Rhizopus, and Trichoderma, five Stachybotrys strains, and the indoor air allergens Can f 1, Der p 1, and Fel d 1. For test buildings, the results showed that detectable toxin concentrations increased with the sampling time and short periods of air disturbance. Trichothecene values ranged from <10 to >1,300 pg/m3 of sampled air. The control environments demonstrated statistically significantly (P < 0.001) lower levels of airborne trichothecenes. ELISA specificity experiments demonstrated a high specificity for the trichothecene-producing strain of S. chartarum. Our data indicate that airborne macrocyclic trichothecenes can exist in Stachybotrys-contaminated buildings, and this should be taken into consideration in future indoor air quality investigations.

  13. Metagenomic survey of bacterial diversity in the atmosphere of Mexico City using different sampling methods.

    PubMed

    Serrano-Silva, N; Calderón-Ezquerro, M C

    2018-04-01

    The identification of airborne bacteria has traditionally been performed by retrieval in culture media, but the bacterial diversity in the air is underestimated using this method because many bacteria are not readily cultured. Advances in DNA sequencing technology have produced a broad knowledge of genomics and metagenomics, which can greatly improve our ability to identify and study the diversity of airborne bacteria. However, researchers are facing several challenges, particularly the efficient retrieval of low-density microorganisms from the air and the lack of standardized protocols for sample collection and processing. In this study, we tested three methods for sampling bioaerosols - a Durham-type spore trap (Durham), a seven-day recording volumetric spore trap (HST), and a high-throughput 'Jet' spore and particle sampler (Jet) - and recovered metagenomic DNA for 16S rDNA sequencing. Samples were simultaneously collected with the three devices during one week, and the sequencing libraries were analyzed. A simple and efficient method for collecting bioaerosols and extracting good quality DNA for high-throughput sequencing was standardized. The Durham sampler collected preferentially Cyanobacteria, the HST Actinobacteria, Proteobacteria and Firmicutes, and the Jet mainly Proteobacteria and Firmicutes. The HST sampler collected the largest amount of airborne bacterial diversity. More experiments are necessary to select the right sampler, depending on study objectives, which may require monitoring and collecting specific airborne bacteria. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Personal exposure to JP-8 jet fuel vapors and exhaust at air force bases.

    PubMed Central

    Pleil, J D; Smith, L B; Zelnick, S D

    2000-01-01

    JP-8 jet fuel (similar to commercial/international jet A-1 fuel) is the standard military fuel for all types of vehicles, including the U.S. Air Force aircraft inventory. As such, JP-8 presents the most common chemical exposure in the Air Force, particularly for flight and ground crew personnel during preflight operations and for maintenance personnel performing routine tasks. Personal exposure at an Air Force base occurs through occupational exposure for personnel involved with fuel and aircraft handling and/or through incidental exposure, primarily through inhalation of ambient fuel vapors. Because JP-8 is less volatile than its predecessor fuel (JP-4), contact with liquid fuel on skin and clothing may result in prolonged exposure. The slowly evaporating JP-8 fuel tends to linger on exposed personnel during their interaction with their previously unexposed colleagues. To begin to assess the relative exposures, we made ambient air measurements and used recently developed methods for collecting exhaled breath in special containers. We then analyzed for certain volatile marker compounds for JP-8, as well as for some aromatic hydrocarbons (especially benzene) that are related to long-term health risks. Ambient samples were collected by using compact, battery-operated, personal whole-air samplers that have recently been developed as commercial products; breath samples were collected using our single-breath canister method that uses 1-L canisters fitted with valves and small disposable breathing tubes. We collected breath samples from various groups of Air Force personnel and found a demonstrable JP-8 exposure for all subjects, ranging from slight elevations as compared to a control cohort to > 100 [mutilpe] the control values. This work suggests that further studies should be performed on specific issues to obtain pertinent exposure data. The data can be applied to assessments of health outcomes and to recommendations for changes in the use of personal protective equipment that optimize risk reduction without undue impact on a mission. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 PMID:10706522

  15. Study on the impact of industrial flue gases on the PCDD/Fs congener profile in ambient air.

    PubMed

    Węgiel, Małgorzata; Chrząszcz, Ryszard; Maślanka, Anna; Grochowalski, Adam

    2014-11-01

    The aim of this study was to examine the impact of emissions from combustion processes from sinter, medical, waste and sewage waste incineration plants on the PCDD and PCDF congener profile in ambient air in Krakow (city in Poland). The subject matter of the study were air samples from the outskirts and the city center. It was found that in flue gases from industrial sources and in ambient air the share of PCDF congeners in relation to the total content of PCDD/Fs was higher than the share of PCDDs. However, in air samples collected in the city center, this relationship was reversed. The PCDD congener profiles in flue gases and in air samples are comparable. However, in the samples from the city centre, the share of OCDD is significantly higher and amounts to about 80%. The PCDF congener shares show higher spatial diversity, although in all the analyzed air samples, ODCF and 1,2,3,4,6,7,8 HpCDF dominated. Analyzing the share of congeners in regard to the sum of PCDDs/Fs a mutual resemblance of air from the suburbs, exhaust gases from the sinter ore and sewage sludge incinerator plant was observed. The study showed a similarity between the profile of congeners in air from the city centre and exhaust gases from the medical waste incinerator. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Design and laboratory testing of a new flow-through directional passive air sampler for ambient particulate matter.

    PubMed

    Lin, Chun; Solera Garcia, Maria Angeles; Timmis, Roger; Jones, Kevin C

    2011-03-01

    A new type of directional passive air sampler (DPAS) is described for collecting particulate matter (PM) in ambient air. The prototype sampler has a non-rotating circular sampling tray that is divided into covered angular channels, whose ends are open to winds from sectors covering the surrounding 360°. Wind-blown PM from different directions enters relevant wind-facing channels, and is retained there in collecting pools containing various sampling media. Information on source direction and type can be obtained by examining the distribution of PM between channels. Wind tunnel tests show that external wind velocities are at least halved over an extended area of the collecting pools, encouraging PM to settle from the air stream. Internal and external wind velocities are well-correlated over an external velocity range of 2.0-10.0 m s⁻¹, which suggests it may be possible to relate collected amounts of PM simply to ambient concentrations and wind velocities. Measurements of internal wind velocities in different channels show that velocities decrease from the upwind channel round to the downwind channel, so that the sampler effectively resolves wind directions. Computational fluid dynamics (CFD) analyses were performed on a computer-generated model of the sampler for a range of external wind velocities; the results of these analyses were consistent with those from the wind tunnel. Further wind tunnel tests were undertaken using different artificial particulates in order to assess the collection performance of the sampler in practice. These tests confirmed that the sampler can resolve the directions of sources, by collecting particulates preferentially in source-facing channels.

  17. Air and smear sample calculational tool for Fluor Hanford Radiological control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BAUMANN, B.L.

    2003-07-11

    A spreadsheet calculation tool was developed to automate the calculations performed for determining the concentration of airborne radioactivity and smear counting as outlined in HNF-13536, Section 5.2.7, ''Analyzing Air and Smear Samples''. This document reports on the design and testing of the calculation tool. Radiological Control Technicians (RCTs) will save time and reduce hand written and calculation errors by using an electronic form for documenting and calculating work place air samples. Current expectations are RCTs will perform an air sample and collect the filter or perform a smear for surface contamination. RCTs will then survey the filter for gross alphamore » and beta/gamma radioactivity and with the gross counts utilize either hand calculation method or a calculator to determine activity on the filter. The electronic form will allow the RCT with a few key strokes to document the individual's name, payroll, gross counts, instrument identifiers; produce an error free record. This productivity gain is realized by the enhanced ability to perform mathematical calculations electronically (reducing errors) and at the same time, documenting the air sample.« less

  18. Relative efficiencies of two air sampling methods and three culture conditions for the assessment of airborne culturable fungi in a poultry farmhouse in France.

    PubMed

    Nieguitsila, Adélaïde; Arné, Pascal; Durand, Benoît; Deville, Manjula; Benoît-Valiergue, Hélène; Chermette, René; Cottenot-Latouche, Sophie; Guillot, Jacques

    2011-02-01

    Fungal elements represent a significant part of the biological contaminants that could be detected in the air of animal facilities. The aim of this study was to assess the relative efficiencies of two air sampling methods and three culture conditions for the quantification of airborne culturable fungi in a poultry farmhouse in France. Air samples were collected every week throughout a 15-week period. Two devices were simultaneously used-a rotative cup air sampler (CIP 10-M, Arelco, France) and an air sampler based on filtration (AirPort MD8, Sartorius, Germany). Culture of airborne viable fungi was performed on malt extract agar (ME) and dichloran glycerol-18 (DG18) at 25 or 37°C. CIP 10-M and AirPort MD8 were shown to display comparable performances but significant differences were observed between culture conditions for Aspergillus spp. (p<0.01), Scopulariopsis spp. (p=0.02) and unidentified molds (p<0.01). Copyright © 2010 Elsevier Inc. All rights reserved.

  19. Insights from two industrial hygiene pilot e-cigarette passive vaping studies.

    PubMed

    Maloney, John C; Thompson, Michael K; Oldham, Michael J; Stiff, Charles L; Lilly, Patrick D; Patskan, George J; Shafer, Kenneth H; Sarkar, Mohamadi A

    2016-01-01

    While several reports have been published using research methods of estimating exposure risk to e-cigarette vapors in nonusers, only two have directly measured indoor air concentrations from vaping using validated industrial hygiene sampling methodology. Our first study was designed to measure indoor air concentrations of nicotine, menthol, propylene glycol, glycerol, and total particulates during the use of multiple e-cigarettes in a well-characterized room over a period of time. Our second study was a repeat of the first study, and it also evaluated levels of formaldehyde. Measurements were collected using active sampling, near real-time and direct measurement techniques. Air sampling incorporated industrial hygiene sampling methodology using analytical methods established by the National Institute of Occupational Safety and Health and the Occupational Safety and Health Administration. Active samples were collected over a 12-hr period, for 4 days. Background measurements were taken in the same room the day before and the day after vaping. Panelists (n = 185 Study 1; n = 145 Study 2) used menthol and non-menthol MarkTen prototype e-cigarettes. Vaping sessions (six, 1-hr) included 3 prototypes, with total number of puffs ranging from 36-216 per session. Results of the active samples were below the limit of quantitation of the analytical methods. Near real-time data were below the lowest concentration on the established calibration curves. Data from this study indicate that the majority of chemical constituents sampled were below quantifiable levels. Formaldehyde was detected at consistent levels during all sampling periods. These two studies found that indoor vaping of MarkTen prototype e-cigarette does not produce chemical constituents at quantifiable levels or background levels using standard industrial hygiene collection techniques and analytical methods.

  20. Toxicological Assessment of ISS Air Quality: June - September 2013 (Increment 36)

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie

    2014-01-01

    Fourteen mini grab sample containers (msGSCs) were collected on ISS between June and September 2013 and were returned on 34S; however, the ATV-4 first ingress mGSC did not contain sufficient sample to report results (initial sample pressure = 1.2 psia). Of the remaining 13 mGSCs, 12 were collected as routine monthly samples in the Russian Service Module (SM), US Laboratory (Lab), and either the Japanese Pressurized Module (JPM) or the Columbus module (Col), and 1 was collected during HTV-4 first ingress. A summary of the analytical results from the 13 valid mGSCs is shown.

  1. Results of a long-term study of vapor intrusion at four large buildings at the NASA Ames Research Center.

    PubMed

    Brenner, David

    2010-06-01

    Most of the published empirical data on indoor air concentrations resulting from vapor intrusion of contaminants from underlying groundwater are for residential structures. The National Aeronautics and Space Administration (NASA) Research Park site, located in Moffett Field, CA, and comprised of 213 acres, is being planned for redevelopment as a collaborative research and educational campus with associated facilities. Groundwater contaminated with hydrocarbon and halogenated hydrocarbon volatile organic compounds (VOCs) is the primary environmental medium of concern at the site. Over a 15-month period, approximately 1000 indoor, outdoor ambient, and outdoor ambient background samples were collected from four buildings designated as historical landmarks using Summa canisters and analyzed by the U.S. Environmental Protection Agency TO-15 selective ion mode. Both 24-hr and sequential 8-hr samples were collected. Comparison of daily sampling results relative to daily background results indicates that the measured trichloroethylene (TCE) concentrations were primarily due to the subsurface vapor intrusion pathway, although there is likely some contribution due to infiltration of TCE from the outdoor ambient background concentrations. Analysis of the cis-1,2-dichloroethylene concentrations relative to TCE concentrations with respect to indoor air concentrations and the background air support this hypothesis; however, this indicates that relative contributions of the vapor intrusion and infiltration pathways vary with each building. Indoor TCE concentrations were also compared with indoor benzene and background benzene concentrations. These data indicate significant correlation between background benzene concentrations and the concentration of benzene in the indoor air, indicating benzene was present in the indoor air primarily through infiltration of outdoor air into the indoor space. By comparison, measured TCE indoor air concentrations showed a significantly different relationship to background concentrations. Analysis of the results show that indoor air samples can be used to definitively define the source of the TCE present in the indoor air space of large industrial buildings.

  2. Miniature open channel scrubbers for gas collection.

    PubMed

    Toda, Kei; Koga, Tomoko; Tanaka, Toshinori; Ohira, Shin-Ichi; Berg, Jordan M; Dasgupta, Purnendu K

    2010-10-15

    An open channel scrubber is proposed as a miniature fieldable gas collector. The device is 100mm in length, 26 mm in width and 22 mm in thickness. The channel bottom is rendered hydrophilic and liquid flows as a thin layer on the bottom. Air sample flows atop the appropriately chosen flowing liquid film and analyte molecules are absorbed into the liquid. There is no membrane at the air-liquid interface: they contact directly each other. Analyte species collected over a 10 min interval are determined by fluorometric flow analysis or ion chromatography. A calculation algorithm was developed to estimate the collection efficiency a priori; experimental and simulated results agreed well. The characteristics of the open channel scrubber are discussed in this paper from both theoretical and experimental points of view. In addition to superior collection efficiencies at relatively high sample air flow rates, this geometry is particularly attractive that there is no change in collection performance due to membrane fouling. We demonstrate field use for analysis of ambient SO(2) near an active volcano. This is basic investigation of membraneless miniature scrubber and is expected to lead development of an excellent micro-gas analysis system integrated with a detector for continuous measurements. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Atmospheric Carbon Monoxide Mixing Ratios NOAA Climate Monitoring and Diagnostics Laboratory Cooperative Air Sampling Network (1988-1993) (DB1011)

    DOE Data Explorer

    Novelli, P. C.; Masarie, K. A.

    1994-01-01

    Individual site files provide CO mixing ratios in parts per billion (ppb) (ppb = parts in 109 by mole fraction) based on measurements from the NOAA/CMDL Cooperative Air Sampling Network beginning 1988. Data are provided through June 1993 for stations at which the first sample was collected before July 1991. All samples were analyzed for CO at the NOAA/CMDL laboratory in Boulder by gas chromatography with mercuric oxide reduction detection, and all measurements are referenced to the CMDL CO scale (Novelli et al., 1991, Novelli et al., 1994).

  4. Results of soil, ground-water, surface-water, and streambed-sediment sampling at Air Force Plane 85, Columbus, Ohio, 1996

    USGS Publications Warehouse

    Parnell, J.M.

    1997-01-01

    The U.S. Geological Survey (USGS), in cooperation with Aeronautical Systems Center, Environmental Management Directorate, Restoration Division, prepared the Surface- and Ground- Water Monitoring Work Plan for Air Force Plant 85 (AFP 85 or Plant), Columbus, Ohio, under the Air Force Installation Restoration Program to characterize any ground-water, surface-water, and soil contamination that may exist at AFP 85. The USGS began the study in November 1996. The Plant was divided into nine sampling areas, which included some previously investi gated study sites. The investigation activities included the collection and presentation of data taken during drilling and water-quality sampling. Data collection focused on the saturated and unsatur ated zones and surface water. Twenty-three soil borings were completed. Ten monitoring wells (six existing wells and four newly constructed monitoring wells) were selected for water-quality sam pling. Surface-water and streambed-sediment sampling locations were chosen to monitor flow onto and off of the Plant. Seven sites were sampled for both surface-water and streambed-sediment quality. This report presents data on the selected inorganic and organic constituents in soil, ground water, surface water, and streambed sediments at AFP 85. The methods of data collection and anal ysis also are included. Knowledge of the geologic and hydrologic setting could aid Aeronautical Systems Center, Environmental Management Directorate, Restoration Division, and its governing regulatory agencies in future remediation studies.

  5. Particle impactor assembly for size selective high volume air sampler

    DOEpatents

    Langer, Gerhard

    1988-08-16

    Air containing entrained particulate matter is directed through a plurality of parallel, narrow, vertically oriented impactor slots of an inlet element toward an adjacently located, relatively large, dust impaction surface preferably covered with an adhesive material. The air flow turns over the impaction surface, leaving behind the relatively larger particles according to the human thoracic separation system and passes through two elongate exhaust apertures defining the outer bounds of the impaction collection surface to pass through divergent passages which slow down and distribute the air flow, with entrained smaller particles, over a fine filter element that separates the fine particles from the air. The elongate exhaust apertures defining the impaction collection surface are spaced apart by a distance greater than the lengths of elongate impactor slots in the inlet element and are oriented to be normal thereto. By appropriate selection of dimensions and the number of impactor slots air flow through the inlet element is provided a nonuniform velocity distribution with the lower velocities being obtained near the center of the impactor slots, in order to separate out particles larger than a certain predetermined size on the impaction collection surface. The impaction collection surface, even in a moderately sized apparatus, is thus relatively large and permits the prolonged sampling of air for periods extending to four weeks.

  6. Microbial air quality and bacterial surface contamination in ambulances during patient services.

    PubMed

    Luksamijarulkul, Pipat; Pipitsangjan, Sirikun

    2015-03-01

    We sought to assess microbial air quality and bacterial surface contamination on medical instruments and the surrounding areas among 30 ambulance runs during service. We performed a cross-sectional study of 106 air samples collected from 30 ambulances before patient services and 212 air samples collected during patient services to assess the bacterial and fungal counts at the two time points. Additionally, 226 surface swab samples were collected from medical instrument surfaces and the surrounding areas before and after ambulance runs. Groups or genus of isolated bacteria and fungi were preliminarily identified by Gram's stain and lactophenol cotton blue. Data were analyzed using descriptive statistics, t-test, and Pearson's correlation coefficient with a p-value of less than 0.050 considered significant. The mean and standard deviation of bacterial and fungal counts at the start of ambulance runs were 318±485cfu/m(3) and 522±581cfu/m(3), respectively. Bacterial counts during patient services were 468±607cfu/m(3) and fungal counts were 656±612cfu/m(3). Mean bacterial and fungal counts during patient services were significantly higher than those at the start of ambulance runs, p=0.005 and p=0.030, respectively. For surface contamination, the overall bacterial counts before and after patient services were 0.8±0.7cfu/cm(2) and 1.3±1.1cfu/cm(2), respectively (p<0.001). The predominant isolated bacteria and fungi were Staphylococcus spp. and Aspergillus spp., respectively. Additionally, there was a significantly positive correlation between bacterial (r=0.3, p<0.010) and fungal counts (r=0.2, p=0.020) in air samples and bacterial counts on medical instruments and allocated areas. This study revealed high microbial contamination (bacterial and fungal) in ambulance air during services and higher bacterial contamination on medical instrument surfaces and allocated areas after ambulance services compared to the start of ambulance runs. Additionally, bacterial and fungal counts in ambulance air showed a significantly positive correlation with the bacterial surface contamination on medical instruments and allocated areas. Further studies should be conducted to determine the optimal intervention to reduce microbial contamination in the ambulance environment.

  7. Atmospheric Sampling on Ascension Island Using Multirotor UAVs.

    PubMed

    Greatwood, Colin; Richardson, Thomas S; Freer, Jim; Thomas, Rick M; MacKenzie, A Rob; Brownlow, Rebecca; Lowry, David; Fisher, Rebecca E; Nisbet, Euan G

    2017-05-23

    As part of an NERC-funded project investigating the southern methane anomaly, a team drawn from the Universities of Bristol, Birmingham and Royal Holloway flew small unmanned multirotors from Ascension Island for the purposes of atmospheric sampling. The objective of these flights was to collect air samples from below, within and above a persistent atmospheric feature, the Trade Wind Inversion, in order to characterise methane concentrations and their isotopic composition. These parameters allow the methane in the different air masses to be tied to different source locations, which can be further analysed using back trajectory atmospheric computer modelling. This paper describes the campaigns as a whole including the design of the bespoke eight rotor aircraft and the operational requirements that were needed in order to collect targeted multiple air samples up to 2.5 km above the ground level in under 20 min of flight time. Key features of the system described include real-time feedback of temperature and humidity, as well as system health data. This enabled detailed targeting of the air sampling design to be realised and planned during the flight mission on the downward leg, a capability that is invaluable in the presence of uncertainty in the pre-flight meteorological data. Environmental considerations are also outlined together with the flight plans that were created in order to rapidly fly vertical transects of the atmosphere whilst encountering changing wind conditions. Two sampling campaigns were carried out in September 2014 and July 2015 with over one hundred high altitude sampling missions. Lessons learned are given throughout, including those associated with operating in the testing environment encountered on Ascension Island.

  8. Ecological succession of the microbial communities of an air-conditioning cooling coil in the tropics.

    PubMed

    Acerbi, E; Chénard, C; Miller, D; Gaultier, N E; Heinle, C E; Chang, V W-C; Uchida, A; Drautz-Moses, D I; Schuster, S C; Lauro, F M

    2017-03-01

    Air-conditioning systems harbor microorganisms, potentially spreading them to indoor environments. While air and surfaces in air-conditioning systems are periodically sampled as potential sources of indoor microbes, little is known about the dynamics of cooling coil-associated communities and their effect on the downstream airflow. Here, we conducted a 4-week time series sampling to characterize the succession of an air-conditioning duct and cooling coil after cleaning. Using an universal primer pair targeting hypervariable regions of the 16S/18S ribosomal RNA, we observed a community succession for the condensed water, with the most abundant airborne taxon Agaricomycetes fungi dominating the initial phase and Sphingomonas bacteria becoming the most prevalent taxa toward the end of the experiment. Duplicate air samples collected upstream and downstream of the coil suggest that the system does not act as ecological filter or source/sink for specific microbial taxa during the duration of the experiment. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Seasonal Fluctuations in Air Pollution in Dazaifu, Japan, and Effect of Long-Range Transport from Mainland East Asia.

    PubMed

    Coulibaly, Souleymane; Minami, Hiroki; Abe, Maho; Hasei, Tomohiro; Sera, Nobuyuki; Yamamoto, Shigekazu; Funasaka, Kunihiro; Asakawa, Daichi; Watanabe, Masanari; Honda, Naoko; Wakabayashi, Keiji; Watanabe, Tetsushi

    2015-01-01

    To clarify the seasonal fluctuations in air pollution and the effect of long-range transport, we collected airborne particles (n=118) at Dazaifu in Fukuoka, Japan, from June 2012 to May 2013 and measured Pb and SO4(2-), which are indicators of the long-range transport of anthropogenic air pollutants, as well as their mutagenicity, and other factors. The levels of airborne particles, Pb, and SO4(2-) were very high on March 4, 8, 9, and 19, and May 13, 21, and 22, 2013. The backward trajectories indicated that air masses had arrived from the Gobi Desert and northern China on those days. The mutagenicity of airborne particles was examined using the Ames test on Salmonella typhimurium YG1024. Highly mutagenic airborne particles were mostly collected in winter, and most of them showed high activity both with and without S9 mix. High levels of polycyclic aromatic hydrocarbons (PAHs) were found in many samples that showed high mutagenicity. For the samples collected on January 30, February 21, and March 4, the levels of Pb, SO4(2-), PAHs, and mutagenicity were high, and the backward trajectories indicated that air masses present on those days had passed through northern or central China. The Japan Meteorological Agency registered Asian dust events at Fukuoka on March 8, 9, and 19, 2013. The results of the present study suggest that high levels of anthropogenic air pollutants were transported with Asian dust. Similarly, long-range transport of air pollutants including mutagens occurred on days when Asian dust events were not registered.

  10. Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air. Part 2. Sorbent selection and other aspects of optimizing air monitoring methods.

    PubMed

    Woolfenden, Elizabeth

    2010-04-16

    Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Applications range from atmospheric research and ambient air monitoring (indoor and outdoor) to occupational hygiene (personal exposure assessment) and measuring chemical emission levels. Part 1 of this paper reviewed the main sorbent-based air sampling strategies including active (pumped) tube monitoring, diffusive (passive) sampling onto sorbent tubes/cartridges plus sorbent trapping/focusing of whole air samples that are either collected in containers (such as canisters or bags) or monitored online. Options for subsequent extraction and transfer to GC(MS) analysis were also summarised and the trend to thermal desorption (TD)-based methods and away from solvent extraction was explained. As a result of this trend, demand for TD-compatible sorbents (alternatives to traditional charcoal) is growing. Part 2 of this paper therefore continues with a summary of TD-compatible sorbents, their respective advantages and limitations and considerations for sorbent selection. Other analytical considerations for optimizing sorbent-based air monitoring methods are also discussed together with recent technical developments and sampling accessories which have extended the application range of sorbent trapping technology generally. Copyright 2010 Elsevier B.V. All rights reserved.

  11. Reactivity of stratospheric aerosols to small amounts of ammonia in the laboratory environment

    NASA Technical Reports Server (NTRS)

    Hayes, D.; Snetsinger, K.; Ferry, G.; Oberbeck, V.; Farlow, N.

    1980-01-01

    Trace ammonia in laboratory air reacts easily with sulfuric acid aerosol samples to form crystalline ammonium sulfate. Argon atmospheres, however, protect sampling surfaces from ammonia contamination. It is found that atmospheric aerosols treated in this way contain only sulfuric acid. After an hour exposed to laboratory air, these same samples convert to ammonium sulfate. Aerosol particles have been collected, using argon control, to determine if the absence of crystalline sulfate is common. But so far there is no evidence that aerosols are neutralized by ammonia in the stratosphere.

  12. Exposing Underrepresented Groups to Climate Change and Atmospheric Science Through Service Learning and Community-Based Participatory Research

    NASA Astrophysics Data System (ADS)

    Padgett, D.

    2016-12-01

    Tennessee State University (TSU) is among seven partner institutions in the NASA-funded project "Mission Earth: Fusing Global Learning and Observations to Benefit the Environment (GLOBE) with NASA Assets to Build Systemic Innovation in STEM Education." The primary objective at the TSU site is to expose high school students from racial and ethnic groups traditionally underrepresented in STEM to atmospheric science and physical systems associated with climate change. Currently, undergraduate students enrolled in TSU's urban and physical courses develop lessons for high school students focused upon the analysis of global warming phenomena and related extreme weather events. The GLOBE Atmosphere Protocols are emphasized in exercises focused upon the urban heat island (UHI) phenomenon and air quality measurements. Pre-service teachers at TSU, and in-service teachers at four local high schools are being certified in the Atmosphere Protocols. Precipitation, ambient air temperature, surface temperature and other data are collected at the schools through a collaborative learning effort among the high school students, TSU undergraduates, and high school teachers. Data collected and recorded manually in the field are compared to each school's automated Weatherbug station measurements. Students and teachers engage in analysis of NASA imagery as part of the GLOBE Surface Temperature Protocol. At off-campus locations, US Clean Air Act (CAA) criteria air pollutant and Toxic Release Inventory (TRI) air pollutant sampling is being conducted in community-based participatory research (CBPR) format. Students partner with non-profit environmental organizations. Data collected using low-cost air sampling devices is being compared with readings from government air monitors. The GLOBE Aerosols Protocol is used in comparative assessments with air sampling results. Project deliverables include four new GLOBE schools, the enrollment of which is nearly entirely comprised of students underrepresented in STEM. A model for service learning activities with GLOBE to increase underrepresented groups participation in STEM is a second deliverable. A third deliverable, a comprehensive citizen science guidebook for grassroots level air quality assessment, is being developed for wide distribution.

  13. [Distribution Characteristics of Heavy Metals in Environmental Samples Around Electroplating Factories and the Health Risk Assessment].

    PubMed

    Guo, Peng-ran; Lei, Yong-qian; Zhou, Qiao-li; Wang, Chang; Pan, Jia-chuan

    2015-09-01

    This study aimed to investigate the pollution degree and human health risk of heavy metals in soil and air samples around electroplating factories. Soil, air and waste gas samples were collected to measure 8 heavy metals (As, Cd, Cr, Cu, Hg, Ni, Pb and Zn) in two electroplating factories, located in Baiyun district of Guangzhou city. Geoaccumulation index and USEPA Risk Assessment Guidance for Superfund (RAGS) were respectively carried out. Results showed that concentrations of Hg and Pb in waste gas and Cr in air samples were higher than limits of the corresponding quality standards, and concentrations of Cd, Hg and Zn in soil samples reached the moderate pollution level. The HQ and HI of exposure by heavy metals in air and soil samples were both lower than 1, indicating that there was no non-carcinogen risk. CRAs and CRCr in soil samples were beyond the maximum acceptable level of carcinogen risk (10(-4)), and the contribution rate of CRCr to TCR was over 81%. CRCr, CRNi and TCR in air samples were in range of 10(-6) - 10(-4), indicating there was possibly carcinogen risk but was acceptable risk. CR values for children were higher than adults in soils, but were higher for adults in air samples. Correlation analysis revealed that concentrations of heavy metals in soils were significantly correlated with these in waste gas samples, and PCA data showed pollution sources of Cd, Hg and Zn in soils were different from other metals.

  14. BIOGENIC CONTRIBUTIONS TO ATMOSPHERIC VOLATILE ORGANIC COMPOUNDS IN AZUSA CA

    EPA Science Inventory

    An objective of the 1997 Southern California Ozone Study (SCOS97) was to provide an up-to-date assessment of the importance of biogenic emissions for tropospheric ozone production in the South Coast Air Basin. To this end ambient air samples were collected during September 199...

  15. Background Mole Fractions of Hydrocarbons in North America Determined from NOAA Global Reference Network Data

    NASA Astrophysics Data System (ADS)

    Mielke-Maday, I.

    2015-12-01

    The National Oceanic and Atmospheric Administration (NOAA) Global Monitoring Division (GMD) maintains a global reference network for over 50 trace gas species and analyzes discrete air samples collected by this network throughout the world at the Earth System Research Laboratory in Boulder, Colorado. In particular, flask samples are analyzed for a number of hydrocarbons with policy and health relevance such as ozone precursors, greenhouse gases, and hazardous air pollutants. Because this global network's sites are remote and therefore minimally influenced by local anthropogenic emissions, these data yield information about background ambient mole fractions and can provide a context for observations collected in intensive field campaigns, such as the Front Range Air Pollution and Photochemistry Experiment (FRAPPE), the Southeast Nexus (SENEX) study, and the DISCOVER-AQ deployments. Information about background mole fractions during field campaigns is critical for calculating hydrocarbon enhancements in the region of study and for assessing the extent to which a particular region's local emissions sources contribute to these enhancements. Understanding the geographic variability of the background and its contribution to regional ambient mole fractions is also crucial for the development of realistic regulations. We present background hydrocarbon mole fractions and their ratios in North America using data from air samples collected in the planetary boundary layer at tall towers and aboard aircraft from 2008 to 2014. We discuss the spatial and seasonal variability in these data. We present trends over the time period of measurements and propose possible explanations for these trends.

  16. [Chemical hazards in the workplace environment of painting restorer].

    PubMed

    Jezewska, Anna; Szewczyńska, Małgorzata

    2012-01-01

    This paper presents the results of the identification of chemical substances present in the air in the workplace of painting restorer. Identification tests were carried out in university and museum easel paintings conservation studios. Air samples were taken for testing at various stages of restoration works. In the qualitative analysis chemical substances in the air samples were measured by GC-MSD and HPLC-DAD methods. In the air samples collected during the cleaning of paintings, such substances as aliphatic and aromatic hydrocarbons, acetone, ethanol and terpenes were mainly identified. While the painting was doubled toluene and while varnished, propan-2-ol, propane, butane and substances derived from turpentine and white spirit were mainly emitted. During the course of painting conservation numerous chemical substances that may pose a threat to the worker's health were identified in their breathing zone.

  17. CHEMICAL AND PHYSICAL CHARACTERISTICS OF OUTDOOR, INDOOR, AND PERSONAL PARTICULATE AIR SAMPLES COLLECTED IN AND AROUND A RETIREMENT FACILITY

    EPA Science Inventory

    Residential, personal, indoor, and outdoor sampling of particulate matter was conducted at a retirement center in the Towson area of northern Baltimore County in 1998. Concurrent sampling was conducted at a central community site. Computer-controlled scanning electron microsco...

  18. Quantitative measurement of airborne cockroach allergen in New York City apartments

    PubMed Central

    Esposito, W. A.; Chew, G. L.; Correa, J. C.; Chillrud, S. N.; Miller, R. L.; Kinney, P. L.

    2013-01-01

    We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10–15 LPM in 19 New York City apartments in which an asthmatic child who was allergic to cockroach allergen resided. Four simultaneous air samples were collected in each home: at heights of 0.3 and 1 m in the child's bedroom and in the kitchen. Extracts of air samples were analyzed by ELISA for the cockroach allergen Bla g2, modified by amplifying the colorimetric signal generated via use of AMPLI-Q detection system (DAKO Corporation, Carpinteria, CA, USA). Settled dust samples were quantified by conventional ELISA. Of the homes where cockroach allergen was detected in settled dust, Bla g2 also was detected in 87% and 93% of air samples in the bedroom and kitchen, respectively. Airborne Bla g2 levels were highly correlated within and between the bedroom and kitchen locations (P < 0.001). Expressed as picogram per cubic meter, the room average geometric mean for Bla g2 concentrations was 1.9 pg/m3 (95% CI 0.63, 4.57) and 3.8 pg/m3 (95% CI 1.35, 9.25) in bedrooms and kitchens, respectively. This method offers an attractive supplement to settled dust sampling for cockroach allergen exposure health studies. PMID:21658130

  19. Volatile Organic Compound Emissions from Dairy Farming and their effect on San Joaquin Valley Air Quality

    NASA Astrophysics Data System (ADS)

    Blake, D. R.; Yang, M.; Meinardi, S.; Krauter, C.; Rowland, F. S.

    2009-05-01

    The San Joaquin Valley Air Pollution Control District of California issued a report identifying dairies as a main source of Volatile Organic Compounds (VOCs). A dairy study funded by the California Air Resources Board commenced shortly after the report was issued. Our University of California Irvine group teamed with California State University Fresno to determine the major sources of VOCs from various dairy operations and from a variety of dairy types. This study identified ethanol and methanol as two gases produced in major quantities throughout the dairies in the San Joaquin valley as by-products of yeast fermentation of silage. Three different types of sampling protocols were employed in order to determine the degree of enhancement of the target oxygenates in the valley air shed. Their sources, emission profiles, and emission rates were determined from whole air samples collected at various locations at the six dairies studied. An assessment of the impact of dairy emissions in the valley was achieved by using data obtained on low altitude NASA DC-8 flights through the valley, and from ground level samples collected though out the valley in a grid like design. Our data suggest that a significant amount of O3 production in the valley may come from methanol, ethanol, and acetaldehyde (a photochemical by-product ethanol oxidation). Our findings indicate that improvement to valley air quality may be obtained by focusing on instituting new silage containment practices and regulations.

  20. Associations between PBDEs in Office Air, Dust, and Surface Wipes

    PubMed Central

    Watkins, Deborah J.; McClean, Michael D.; Fraser, Alicia J.; Weinberg, Janice; Stapleton, Heather M.; Webster, Thomas F.

    2013-01-01

    Increased use of flame-retardants in office furniture may increase exposure to PBDEs in the office environment. However, partitioning of PBDEs within the office environment is not well understood. Our objectives were to examine relationships between concurrent measures of PBDEs in office air, floor dust, and surface wipes. We collected air, dust, and surface wipe samples from 31 offices in Boston, MA. Correlation and linear regression were used to evaluate associations between variables. Geometric mean (GM) concentrations of individual BDE congeners in air and congener specific octanol-air partition coefficients (Koa) were used to predict GM concentrations in dust and surface wipes and compared to the measured concentrations. GM concentrations of PentaBDEs in office air, dust, and surface wipes were 472 pg/m3, 2411 ng/g, and 77 pg/cm2, respectively. BDE209 was detected in 100% of dust samples (GM=4202 ng/g), 93% of surface wipes (GM=125 pg/cm2), and 39% of air samples. PentaBDEs in dust and air were moderately correlated with each other (r=0.60, p=0.0003), as well as with PentaBDEs in surface wipes (r=0.51, p=0.003 for both dust and air). BDE209 in dust was correlated with BDE209 in surface wipes (r=0.69, p=0.007). Building (three categories) and PentaBDEs in dust were independent predictors of PentaBDEs in both air and surface wipes, together explaining 50% (p=0.0009) and 48% (p=0.001) of the variation respectively. Predicted and measured concentrations of individual BDE congeners were highly correlated in dust (r=0.98, p<0.0001) and surface wipes (r=0.94, p=002). BDE209 provided an interesting test of this equilibrium partitioning model as it is a low volatility compound. Associations between PentaBDEs in multiple sampling media suggest that collecting dust or surface wipes may be a convenient method of characterizing exposure in the indoor environment. The volatility of individual congeners, as well as physical characteristics of the indoor environment, influence relationships between PBDEs in air, dust, and surface wipes. PMID:23797055

  1. Does the Exposure of Urine Samples to Air Affect Diagnostic Tests for Urine Acidification?

    PubMed Central

    Yi, Joo-Hark; Shin, Hyun-Jong; Kim, Sun-Moon; Han, Sang-Woong; Oh, Man-Seok

    2012-01-01

    Summary Background and objectives For accurate measurement of pH, urine collection under oil to limit the escape of CO2 on air exposure is recommended. This study aims to test the hypothesis that urine collection under oil is not necessary in acidic urine in which bicarbonate and CO2 are minor buffers, because loss of CO2 would have little effect on its pH. Design, setting, participants, & measurements One hundred consecutive random urine samples were collected under oil and analyzed for pH, pCO2, and HCO3− immediately and after 5 minutes of vigorous shaking in uncovered flasks to allow CO2 escape. Results The pH values in 97 unshaken samples ranged from 5.03 to 6.83. With shaking, urine pCO2 decreased by 76%, whereas urine HCO3− decreased by 60%. Meanwhile, urine baseline median pH (interquartile range) of 5.84 (5.44–6.25) increased to 5.93 (5.50–6.54) after shaking (ΔpH=0.12 [0.07–0.29], P<0.001). ΔpH with pH≤6.0 was significantly lower than the ΔpH with pH>6.0 (0.08 [0.05–0.12] versus 0.36 [0.23–0.51], P<0.001). Overall, the lower the baseline pH, the smaller the ΔpH. Conclusions The calculation of buffer reactions in a hypothetical acidic urine predicted a negligible effect on urine pH on loss of CO2 by air exposure, which was empirically proven by the experimental study. Therefore, exposure of urine to air does not substantially alter the results of diagnostic tests for urine acidification, and urine collection under oil is not necessary. PMID:22700881

  2. 77 FR 48554 - Agency Information Collection Activities: Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-14

    ... number. SUPPLEMENTARY INFORMATION: Title of Collection: Survey of Laboratory Equipment Donations for... and secondary schools. The Director * * * shall survey institutions of higher education and entities... for Research (AIR) has designed a sample of institutions of higher education (IHEs) drawn from the...

  3. BP Spill Sampling and Monitoring Data April-September 2010 - Data Download Tool

    EPA Pesticide Factsheets

    This dataset analyzes waste from the the British Petroleum Deepwater Horizon Rig Explosion Emergency Response, providing opportunity to query data sets by metadata criteria and find resulting raw datasets in CSV format.The data query tool allows users to download air, water and sediment sampling and monitoring data that has been collected in response to the BP oil spill. All sampling and monitoring data that has been collected to date is available for download as raw structured data.The query tools enables CSV file creation to be refined based on the following search criteria: date range (between April 28, 2010 and 9/29/2010); location by zip, city, or county; media (solid waste, weathered oil, air, surface water, liquid waste, tar, sediment, water); substance categories (based on media selection) and substances (based on substance category selection).

  4. What measurements tell us about air composition and emissions in three US oil and gas fields

    NASA Astrophysics Data System (ADS)

    Petron, G.; Miller, B. R.; Montzka, S. A.; Dlugokencky, E. J.; Kofler, J.; Sweeney, C.; Karion, A.; Frost, G. J.; Helmig, D.; Hueber, J.; Schnell, R. C.; Conley, S. A.; Tans, P. P.

    2013-12-01

    In 2012 and 2013, the NOAA Global Monitoring Division and several collaborators conducted intensive airborne and ground campaigns in three US oil and gas plays to study emissions of methane and surface ozone precursors. In this presentation we will focus on the multiple species analysis in discrete air samples collected with the NOAA Mobile Laboratory (ML) and the light aircraft in the Uinta Basin (Utah), Denver Julesburg Basin (Colorado) and Barnett Shale (Texas). Hydrocarbon ratios in samples collected with the ML downwind of specific sources show significantly more variability than the aircraft samples. These surface samples provide some useful information about the composition of various sources in each region. Ratios of the non-methane hydrocarbons on the ground and higher in the boundary layer show some differences between the plays, which could be explained by the different composition of the raw gas being produced or by different mixes of sources contributions. Understanding the speciation of atmospheric emissions is critical to identify emission vectors and to assess their potential air quality and climate impacts. Our measurement results will be compared with data from other studies, including emission inventories.

  5. Apparatus and process for collection of gas and vapor samples

    DOEpatents

    Jackson, Dennis G [Augusta, GA; Peterson, Kurt D [Aiken, SC; Riha, Brian D [Augusta, GA

    2008-04-01

    A gas sampling apparatus and process is provided in which a standard crimping tool is modified by an attached collar. The collar permits operation of the crimping tool while also facilitating the introduction of a supply of gas to be introduced into a storage vial. The introduced gas supply is used to purge ambient air from a collection chamber and an interior of the sample vial. Upon completion of the purging operation, the vial is sealed using the crimping tool.

  6. Microbial Groundwater Sampling Protocol for Fecal-Rich Environments

    PubMed Central

    Harter, Thomas; Watanabe, Naoko; Li, Xunde; Atwill, Edward R; Samuels, William

    2014-01-01

    Inherently, confined animal farming operations (CAFOs) and other intense fecal-rich environments are potential sources of groundwater contamination by enteric pathogens. The ubiquity of microbial matter poses unique technical challenges in addition to economic constraints when sampling wells in such environments. In this paper, we evaluate a groundwater sampling protocol that relies on extended purging with a portable submersible stainless steel pump and Teflon® tubing as an alternative to equipment sterilization. The protocol allows for collecting a large number of samples quickly, relatively inexpensively, and under field conditions with limited access to capacity for sterilizing equipment. The protocol is tested on CAFO monitoring wells and considers three cross-contamination sources: equipment, wellbore, and ambient air. For the assessment, we use Enterococcus, a ubiquitous fecal indicator bacterium (FIB), in laboratory and field tests with spiked and blank samples, and in an extensive, multi-year field sampling campaign on 17 wells within 2 CAFOs. The assessment shows that extended purging can successfully control for equipment cross-contamination, but also controls for significant contamination of the well-head, within the well casing and within the immediate aquifer vicinity of the well-screen. Importantly, our tests further indicate that Enterococcus is frequently entrained in water samples when exposed to ambient air at a CAFO during sample collection. Wellbore and air contamination pose separate challenges in the design of groundwater monitoring strategies on CAFOs that are not addressed by equipment sterilization, but require adequate QA/QC procedures and can be addressed by the proposed sampling strategy. PMID:24903186

  7. Pesticides in Mississippi air and rain: A comparison between 1995 and 2007

    USGS Publications Warehouse

    Majewski, Michael S; Coupe, Richard H.; Foreman, William T.; Capel, Paul D.

    2014-01-01

    A variety of current-use pesticides were determined in weekly composite air and rain samples collected during the 1995 and 2007 growing seasons in the Mississippi Delta (MS, USA) agricultural region. Similar sampling and analytical methods allowed for direct comparison of results. Decreased overall pesticide use in 2007 relative to 1995 generally resulted in decreased detection frequencies in air and rain; observed concentration ranges were similar between years, however, even though the 1995 sampling site was 500 m from active fields whereas the 2007 sampling site was within 3 m of a field. Mean concentrations of detections were sometimes greater in 2007 than in 1995, but the median values were often lower. Seven compounds in 1995 and 5 in 2007 were detected in ≥50% of both air and rain samples. Atrazine, metolachlor, and propanil were detected in ≥50% of the air and rain samples in both years. Glyphosate and its degradation product, aminomethyl-phosphonic acid (AMPA), were detected in ≥75% of air and rain samples in 2007 but were not measured in 1995. The 1995 seasonal wet depositional flux was dominated by methyl parathion (88%) and was >4.5 times the 2007 flux. Total herbicide flux in 2007 was slightly greater than in 1995 and was dominated by glyphosate. Malathion, methyl parathion, and degradation products made up most of the 2007 nonherbicide flux.

  8. Pesticides in Mississippi air and rain: a comparison between 1995 and 2007.

    PubMed

    Majewski, Michael S; Coupe, Richard H; Foreman, William T; Capel, Paul D

    2014-06-01

    A variety of current-use pesticides were determined in weekly composite air and rain samples collected during the 1995 and 2007 growing seasons in the Mississippi Delta (MS, USA) agricultural region. Similar sampling and analytical methods allowed for direct comparison of results. Decreased overall pesticide use in 2007 relative to 1995 generally resulted in decreased detection frequencies in air and rain; observed concentration ranges were similar between years, however, even though the 1995 sampling site was 500 m from active fields whereas the 2007 sampling site was within 3 m of a field. Mean concentrations of detections were sometimes greater in 2007 than in 1995, but the median values were often lower. Seven compounds in 1995 and 5 in 2007 were detected in ≥50% of both air and rain samples. Atrazine, metolachlor, and propanil were detected in ≥50% of the air and rain samples in both years. Glyphosate and its degradation product, aminomethyl-phosphonic acid (AMPA), were detected in ≥75% of air and rain samples in 2007 but were not measured in 1995. The 1995 seasonal wet depositional flux was dominated by methyl parathion (88%) and was >4.5 times the 2007 flux. Total herbicide flux in 2007 was slightly greater than in 1995 and was dominated by glyphosate. Malathion, methyl parathion, and degradation products made up most of the 2007 nonherbicide flux. © 2014 SETAC.

  9. Novel sample preparation technique with needle-type micro-extraction device for volatile organic compounds in indoor air samples.

    PubMed

    Ueta, Ikuo; Mizuguchi, Ayako; Fujimura, Koji; Kawakubo, Susumu; Saito, Yoshihiro

    2012-10-09

    A novel needle-type sample preparation device was developed for the effective preconcentration of volatile organic compounds (VOCs) in indoor air before gas chromatography-mass spectrometry (GC-MS) analysis. To develop a device for extracting a wide range of VOCs typically found in indoor air, several types of particulate sorbents were tested as the extraction medium in the needle-type extraction device. To determine the content of these VOCs, air samples were collected for 30min with the packed sorbent(s) in the extraction needle, and the extracted VOCs were thermally desorbed in a GC injection port by the direct insertion of the needle. A double-bed sorbent consisting of a needle packed with divinylbenzene and activated carbon particles exhibited excellent extraction and desorption performance and adequate extraction capacity for all the investigated VOCs. The results also clearly demonstrated that the proposed sample preparation method is a more rapid, simpler extraction/desorption technique than traditional sample preparation methods. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. DICARBOXYLIC ACID CONCENTRATION TRENDS AND SAMPLING ARTIFACTS

    EPA Science Inventory

    Dicarboxylic acids associated with airborne particulate matter were measured during a summer period in Philadelphia that included multiple air pollution episodes. Samples were collected for two ten hour periods each day using a high volume sampler with two quartz fiber filters in...

  11. Indoor air pollution evaluation with emphasize on HDI and biological assessment of HDA in the polyurethane factories.

    PubMed

    Mirmohammadi, Mirtaghi; Hakimi Ibrahim, M; Ahmad, Anees; Kadir, Mohd Omar Abdul; Mohammadyan, M; Mirashrafi, S B

    2010-06-01

    Today, many raw materials used in factories may have a dangerous effect on the physiological system of workers. One of them which is widely used in the polyurethane factories is diisocyanates. These compounds are widely used in surface coatings, polyurethane foams, adhesives, resins, elastomers, binders, and sealants. Exposure to diisocyanates causes irritation to the skin, mucous membranes, eyes, and respiratory tract. Hexamethylene diamine (HDA) is metabolite of hexamethylene diisocyanate (HDI). It is an excretory material by worker's urine who is exposed to HDI. Around 100 air samples were collected from five defined factories by midget impinger which contained dimethyl sulfoxide absorbent as a solvent and tryptamine as reagent. Samples were analyzed by high-performance liquid chromatography with EC\\UV detector using NIOSH 5522 method of sampling. Also, 50 urine samples collected from workers were also analyzed using William's biological analysis method. The concentration of HDI into all air samples were more than 88 microg/m(3), and they have shown high concentration of pollutant in the workplaces in comparison with NIOSH standard, and all of the workers' urine were contaminated by HDA. The correlation and regression test were used to obtain statistical model for HDI and HDA, which is useful for the prediction of diisocyanates pollution situation in the polyurethane factories.

  12. Urinary and breast milk biomarkers to assess exposure to naphthalene in pregnant women: an investigation of personal and indoor air sources

    PubMed Central

    2014-01-01

    Background Naphthalene exposures for most non-occupationally exposed individuals occur primarily indoors at home. Residential indoor sources include pest control products (specifically moth balls), incomplete combustion such as cigarette smoke, woodstoves and cooking, some consumer and building products, and emissions from gasoline sources found in attached garages. The study aim was to assess naphthalene exposure in pregnant women from Canada, using air measurements and biomarkers of exposure. Methods Pregnant women residing in Ottawa, Ontario completed personal and indoor air sampling, and questionnaires. During pregnancy, pooled urine voids were collected over two 24-hour periods on a weekday and a weekend day. At 2–3 months post-birth, they provided a spot urine sample and a breast milk sample following the 24-hour air monitoring. Urines were analyzed for 1-naphthol and 2-naphthol and breast milk for naphthalene. Simple linear regression models examined associations between known naphthalene sources, air and biomarker samples. Results Study recruitment rate was 11.2% resulting in 80 eligible women being included. Weekday and weekend samples were highly correlated for both personal (r = 0.83, p < 0.0001) and indoor air naphthalene (r = 0.91, p < 0.0001). Urine specific gravity (SG)-adjusted 2-naphthol concentrations collected on weekdays and weekends (r = 0.78, p < 0.001), and between pregnancy and postpartum samples (r = 0.54, p < 0.001) were correlated. Indoor and personal air naphthalene concentrations were significantly higher post-birth than during pregnancy (p < 0.0001 for signed rank tests); concurrent urine samples were not significantly different. Naphthalene in breast milk was associated with urinary 1-naphthol: a 10% increase in 1-naphthol was associated with a 1.6% increase in breast milk naphthalene (95% CI: 0.2%-3.1%). No significant associations were observed between naphthalene sources reported in self-administered questionnaires and the air or biomarker concentrations. Conclusions Median urinary concentrations of naphthalene metabolites tended to be similar to (1-naphthol) or lower (2-naphthol) than those reported in a Canadian survey of women of reproductive age. Only urinary 1-naphthol and naphthalene in breast milk were associated. Potential reasons for the lack of other associations include a lack of sources, varying biotransformation rates and behavioural differences over time. PMID:24767676

  13. Qualitative and quantitative determination of human biomarkers by laser photoacoustic spectroscopy methods

    NASA Astrophysics Data System (ADS)

    Popa, C.; Bratu, A. M.; Matei, C.; Cernat, R.; Popescu, A.; Dumitras, D. C.

    2011-07-01

    The hypothesis that blood, urine and other body fluids and tissues can be sampled and analyzed to produce clinical information for disease diagnosis or therapy monitoring is the basis of modern clinical diagnosis and medical practice. The analysis of breath air has major advantages because it is a non-invasive method, represents minimal risk to personnel collecting the samples and can be often sampled. Breath air samples from the human subjects were collected using aluminized bags from QuinTron and analyzed using the laser photoacoustic spectroscopy (LPAS) technique. LPAS is used to detect traces of ethylene in breath air resulting from lipid peroxidation in lung epithelium following the radiotherapy and also traces of ammonia from patients subjected to hemodialysis for treatment of renal failure. In the case of patients affected by cancer and treated by external radiotherapy, all measurements were done at 10P(14) CO2 laser line, where the ethylene absorption coefficient has the largest value (30.4 cm-1 atm-1), whereas for patients affected by renal failure and treated by standard dialysis, all measurements were performed at 9R(30) CO2 laser line, where the ammonia absorption coefficient has the maximum value of 57 cm-1 atm-1. The levels of ethylene and ammonia in exhaled air, from patients with cancer and renal failure, respectively, were measured and compared with breath air contents from healthy humans. Human gas biomarkers were measured at sub-ppb (parts per billion) concentration sensitivities. It has been demonstrated that LPAS technique will play an important role in the future of exhaled breath air analysis. The key attributes of this technique are sensitivity, selectivity, fast and real time response, as well as its simplicity.

  14. Long-term indoor air conditioner filtration and cardiovascular health: A randomized crossover intervention study.

    PubMed

    Chuang, Hsiao-Chi; Ho, Kin-Fai; Lin, Lian-Yu; Chang, Ta-Yuan; Hong, Gui-Bing; Ma, Chi-Ming; Liu, I-Jung; Chuang, Kai-Jen

    2017-09-01

    The association of short-term air pollution filtration with cardiovascular health has been documented. However, the effect of long-term indoor air conditioner filtration on the association between air pollution and cardiovascular health is still unclear. We recruited 200 homemakers from Taipei and randomly assigned 100 of them to air filtration or control intervention; six home visits were conducted per year from 2013 to 2014. The participants under air filtration intervention during 2013 were reassigned to control intervention in 2014. The air pollution measurements consisted of particulate matter less than or equal to 2.5μm in diameter (PM 2.5 ) and total volatile organic compounds (VOCs); blood pressure was monitored for each participant during each visit. The following morning, blood samples were collected after air pollution monitoring. The blood samples were used to analyze biological markers, including high sensitivity-C-reactive protein (hs-CRP), 8-hydroxy-2'-deoxyguanosine (8-OHdG) and fibrinogen. Household information, including cleaning, cooking, and air conditioning, was collected by a questionnaire. Mixed-effects models were used to investigate the associations among air pollution measurements, blood pressure and biological markers. The results showed that increased levels of PM 2.5 and total VOCs were associated with increased hs-CRP, 8-OHdG and blood pressure. The health variables were higher among participants in the control intervention phase than among those in the air filtration intervention phase. We concluded that air pollution exposure was associated with systemic inflammation, oxidative stress and elevated blood pressure. The long-term filtration of air pollution with an air conditioner filter was associated with cardiovascular health of adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Contribution of Vegetation to the Microbial Composition of Nearby Outdoor Air

    PubMed Central

    Adams, Rachel I.

    2016-01-01

    ABSTRACT Given that epiphytic microbes are often found in large population sizes on plants, we tested the hypothesis that plants are quantitatively important local sources of airborne microorganisms. The abundance of microbial communities, determined by quantifying bacterial 16S RNA genes and the fungal internal transcribed spacer (ITS) region, in air collected directly above vegetation was 2- to 10-fold higher than that in air collected simultaneously in an adjacent nonvegetated area 50 m upwind. Nonmetric multidimensional scaling revealed that the composition of airborne bacteria in upwind air samples grouped separately from that of downwind air samples, while communities on plants and downwind air could not be distinguished. In contrast, fungal taxa in air samples were more similar to each other than to the fungal epiphytes. A source-tracking algorithm revealed that up to 50% of airborne bacteria in downwind air samples were presumably of local plant origin. The difference in the proportional abundances of a given operational taxonomic unit (OTU) between downwind and upwind air when regressed against the proportional representation of this OTU on the plant yielded a positive slope for both bacteria and fungi, indicating that those taxa that were most abundant on plants proportionally contributed more to downwind air. Epiphytic fungi were less of a determinant of the microbiological distinctiveness of downwind air and upwind air than epiphytic bacteria. Emigration of epiphytic bacteria and, to a lesser extent, fungi, from plants can thus influence the microbial composition of nearby air, a finding that has important implications for surrounding ecosystems, including the built environment into which outdoor air can penetrate. IMPORTANCE This paper addresses the poorly understood role of bacterial and fungal epiphytes, the inhabitants of the aboveground plant parts, in the composition of airborne microbes in outdoor air. It is widely held that epiphytes contribute to atmospheric microbial assemblages, but much of what we know is limited to qualitative assessments. Elucidating the sources of microbes in outdoor air can inform basic biological processes seen in airborne communities (e.g., dispersal and biogeographical patterns). Furthermore, given the considerable contribution of outdoor air to microbial communities found within indoor environments, the understanding of plants as sources of airborne microbes in outdoor air might contribute to our understanding of indoor air quality. With an experimental design developed to minimize the likelihood of other-than-local plant sources contributing to the composition of airborne microbes, we provide direct evidence that plants are quantitatively important local sources of airborne microorganisms, with implications for the surrounding ecosystems. PMID:27107117

  16. Contribution of Vegetation to the Microbial Composition of Nearby Outdoor Air.

    PubMed

    Lymperopoulou, Despoina S; Adams, Rachel I; Lindow, Steven E

    2016-07-01

    Given that epiphytic microbes are often found in large population sizes on plants, we tested the hypothesis that plants are quantitatively important local sources of airborne microorganisms. The abundance of microbial communities, determined by quantifying bacterial 16S RNA genes and the fungal internal transcribed spacer (ITS) region, in air collected directly above vegetation was 2- to 10-fold higher than that in air collected simultaneously in an adjacent nonvegetated area 50 m upwind. Nonmetric multidimensional scaling revealed that the composition of airborne bacteria in upwind air samples grouped separately from that of downwind air samples, while communities on plants and downwind air could not be distinguished. In contrast, fungal taxa in air samples were more similar to each other than to the fungal epiphytes. A source-tracking algorithm revealed that up to 50% of airborne bacteria in downwind air samples were presumably of local plant origin. The difference in the proportional abundances of a given operational taxonomic unit (OTU) between downwind and upwind air when regressed against the proportional representation of this OTU on the plant yielded a positive slope for both bacteria and fungi, indicating that those taxa that were most abundant on plants proportionally contributed more to downwind air. Epiphytic fungi were less of a determinant of the microbiological distinctiveness of downwind air and upwind air than epiphytic bacteria. Emigration of epiphytic bacteria and, to a lesser extent, fungi, from plants can thus influence the microbial composition of nearby air, a finding that has important implications for surrounding ecosystems, including the built environment into which outdoor air can penetrate. This paper addresses the poorly understood role of bacterial and fungal epiphytes, the inhabitants of the aboveground plant parts, in the composition of airborne microbes in outdoor air. It is widely held that epiphytes contribute to atmospheric microbial assemblages, but much of what we know is limited to qualitative assessments. Elucidating the sources of microbes in outdoor air can inform basic biological processes seen in airborne communities (e.g., dispersal and biogeographical patterns). Furthermore, given the considerable contribution of outdoor air to microbial communities found within indoor environments, the understanding of plants as sources of airborne microbes in outdoor air might contribute to our understanding of indoor air quality. With an experimental design developed to minimize the likelihood of other-than-local plant sources contributing to the composition of airborne microbes, we provide direct evidence that plants are quantitatively important local sources of airborne microorganisms, with implications for the surrounding ecosystems. Copyright © 2016 Lymperopoulou et al.

  17. Vertical profile of elemental concentrations in aerosol particles in the Bermuda area during GCE/CASE/WATOX

    NASA Astrophysics Data System (ADS)

    Ennis, G.; Sievering, H.

    1990-06-01

    During the 1988 Global Change Expedition/Coordinated Air-Sea Experiment/Western Atlantic Ocean Experiment (GCE/CASE/WATOX) joint effort, research was conducted to determine elemental concentrations in atmospheric aerosol particles near Bermuda, to construct a three-level (15, 150, and 2600 m ASL) vertical profile of these concentrations, and to ascertain the source of the particles. Samples were collected by the NOAA King Air aircraft and NOAA ship Mt. Mitchell on July 24-28, 1988. Concentration determinations were made for 16 elements through the use of an X ray fluorescence instrument designed for analysis of small-mass samples. A layering effect was found; concentrations of several elements at 150 m were more than twice their respective concentrations at 15 m and 2600 m. Enrichment factors, V/Mn ratio, and correlations between concentrations suggest a Saharan mineral source, despite air mass back trajectories that show no direct continental input for up to 10 days prior to sample collection. Estimated total mineral aerosol concentrations at 15 m, 150 m, and 2600 m are 1.5, 4.1, and 2.1 μg m-3.

  18. n-Hexane metabolism in occupationally exposed workers.

    PubMed Central

    Mutti, A; Falzoi, M; Lucertini, S; Arfini, G; Zignani, M; Lombardi, S; Franchini, I

    1984-01-01

    Lung uptake and excretion of n-hexane were studied in ten workers in a shoe factory. Simultaneous samples of inhaled and alveolar air were collected with the aid of a Rhan-Otis valve, personal samplers, and charcoal tubes. Alveolar excretion was monitored during a six hour postexposure period. Uptake was calculated from lung ventilation, the retention coefficient, and environmental concentrations. The amount of exhaled n-hexane was calculated from the decay curve. According to the experimental data, alveolar retention was about 25% of the inhaled n-hexane, corresponding to a lung uptake of about 17%. The postexposure alveolar excretion was about 10% of the total uptake. The main metabolites of n-hexane were identified and measured by capillary GC/MS in spot urine samples collected before, at the end, and 15 hours after the same working shift. Urinary concentrations were low, though related to n-hexane in the air. 2,5-Hexanedione in the end of shift samples gave the best estimate of overall exposure. About 3 mg/g creatinine of 2,5-hexanedione would correspond to about 50 ppm of n-hexane in the air (mean daily exposure). PMID:6498115

  19. Apollo Saturn 511 effluent measurements from the Apollo 16 launch operations: An experiment

    NASA Technical Reports Server (NTRS)

    Gregory, G. L.; Hulten, W. C.; Wornom, D. E.

    1974-01-01

    An experiment was performed in conjunction with the Apollo 16 launch to define operational and instrumentational problems associated with launch-vehicle exhaust effluent monitoring. Ground and airborne sampling were performed for CO, CO2, hydrocarbons, and particulates. Sampling systems included filter pads and photometers for particulates and whole-air grab samples for gases. Launch debris was identified in the particulate samples at ground level(taken immediately after launch) and in the airborne measurements (taken 40 to 50 minutes after launch approximately 40 km downwind of the pad). Operational problems were identified and included the need for higher instrumentation mobility and the need for real-time sampling instrumentation as opposed to collection-type samples such as the whole-air grab sample.

  20. Phytoforensics—Using trees to find contamination

    USGS Publications Warehouse

    Wilson, Jordan L.

    2017-09-28

    The water we drink, air we breathe, and soil we come into contact with have the potential to adversely affect our health because of contaminants in the environment. Environmental samples can characterize the extent of potential contamination, but traditional methods for collecting water, air, and soil samples below the ground (for example, well drilling or direct-push soil sampling) are expensive and time consuming. Trees are closely connected to the subsurface and sampling tree trunks can indicate subsurface pollutants, a process called phytoforensics. Scientists at the Missouri Water Science Center were among the first to use phytoforensics to screen sites for contamination before using traditional sampling methods, to guide additional sampling, and to show the large cost savings associated with tree sampling compared to traditional methods. 

  1. Preconcentrator with high volume chiller for high vapor pressure particle detection

    DOEpatents

    Linker, Kevin L

    2013-10-22

    Apparatus and method for collecting particles of both high and low vapor pressure target materials entrained in a large volume sample gas stream. Large volume active cooling provides a cold air supply which is mixed with the sample gas stream to reduce the vapor pressure of the particles. In embodiments, a chiller cools air from ambient conditions to 0-15.degree. C. with the volumetric flow rate of the cold air supply being at least equal to the volumetric flow rate of the sample gas stream. In further embodiments an adsorption media is heated in at least two stages, a first of which is below a threshold temperature at which decomposition products of the high vapor pressure particle are generated.

  2. Air concentrations of PBDEs on in-flight airplanes and assessment of flight crew inhalation exposure.

    PubMed

    Allen, Joseph G; Sumner, Ann Louise; Nishioka, Marcia G; Vallarino, Jose; Turner, Douglas J; Saltman, Hannah K; Spengler, John D

    2013-07-01

    To address the knowledge gaps regarding inhalation exposure of flight crew to polybrominated diphenyl ethers (PBDEs) on airplanes, we measured PBDE concentrations in air samples collected in the cabin air at cruising altitudes and used Bayesian Decision Analysis (BDA) to evaluate the likelihood of inhalation exposure to result in the average daily dose (ADD) of a member of the flight crew to exceed EPA Reference Doses (RfDs), accounting for all other aircraft and non-aircraft exposures. A total of 59 air samples were collected from different aircraft and analyzed for four PBDE congeners-BDE 47, 99, 100 and 209 (a subset were also analyzed for BDE 183). For congeners with a published RfD, high estimates of ADD were calculated for all non-aircraft exposure pathways and non-inhalation exposure onboard aircraft; inhalation exposure limits were then derived based on the difference between the RfD and ADDs for all other exposure pathways. The 95th percentile measured concentrations of PBDEs in aircraft air were <1% of the derived inhalation exposure limits. Likelihood probabilities of 95th percentile exposure concentrations >1% of the defined exposure limit were zero for all congeners with published RfDs.

  3. Density assessment and mapping of microorganisms around a biocomposting plant in Sanandaj, Iran.

    PubMed

    Rashidi, Sanaz; Shahmoradi, B; Maleki, Afshin; Sharafi, Kiomars; Darvishi, Ebrahim

    2017-05-01

    Exposure to microorganisms can cause various diseases or exacerbate the excitatory responses, inflammation, dry cough and shortness of breath, reduced lung function, chronic obstructive pulmonary disease, and allergic response or allergic immune. The aim of the present study was to investigate the density of microorganisms around the air of processing facilities of a biocomposting plant. Each experiment was carried out according to ASTM E884-82 (2001) method. The samples were collected from inhaled air in four locations of the plant, which had a high traffic of workers and employees, including screen, conveyor belt, aerated compost pile, and static compost pile. The sampling was repeated five times for each location selected. The wind speed and its direction were measured using an anemometer. Temperature and humidity were also recorded at the time of sampling. The multistage impactor used for sampling was equipped with a solidified medium (agar) and a pump (with a flow rate of 28.3 l/m) for passing air through the media. It was found that the mean density of total bacteria was >1.7 × 10 3  cfu/m 3 in the study area. Moreover, the mean densities of fungi, intestinal bacteria (Klebsiella), and Staphylococcus aureus were 5.9 × 10 3 , 3.3 × 10 3 , and 4.1 × 10 3  cfu/m 3 , respectively. In conclusion, according to the findings, the density of bacteria and fungi per cubic meter of air in the samples collected around the processing facilities of the biocomposting plant in Sanandaj City was higher than the microbial standard for inhaled air.

  4. Legionella species colonization of water distribution systems, pools and air conditioning systems in cruise ships and ferries

    PubMed Central

    Goutziana, Georgia; Mouchtouri, Varvara A; Karanika, Maria; Kavagias, Antonios; Stathakis, Nikolaos E; Gourgoulianis, Kostantinos; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2008-01-01

    Background Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. Methods Water systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. Results The 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH ≥7.8 and total plate count ≥400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of ≥0.2 mg/L inhibited colonization of Legionella spp. Conclusion WDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members. PMID:19025638

  5. Measurement and estimated health risks of semivolatile organic compounds (PCBs, PAHs, pesticides, and phthalates) in ambient air at the Hanford Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patton, G.W.; Cooper, A.T.; Blanton, M.L.

    1997-09-01

    Air samples for polychlorinated biphenyls (PCBs), chlorinated pesticides, phthalate plasticizers, and polycyclic aromatic hydrocarbons (PAHs) were collected at three Hanford Site locations (300-Area South Gate, southeast of 200-East Area, and a background location near Rattlesnake Springs). Samples were collected using high-volume air samplers equipped with a glass fiber filter and polyurethane foam plug sampling train. Target compounds were extracted from the sampling trains and analyzed using capillary gas chromatography with either electron capture detection or mass selective detection. Twenty of the 28 PCB congeners analyzed were found above the detection limits, with 8 of the congeners accounting for over 80%more » of the average PCB concentrations. The average sum of all individual PCB congeners ranged from 500-740 pg/m{sup 3}, with little apparent difference between the sampling locations. Twenty of the 25 pesticides analyzed were found above the detection limits, with endosulfan I, endosulfan II, and methoxychlor having the highest average concentrations. With the exception of the endosulfans, all other average pesticide concentrations were below 100 pg/m{sup 3}. There was little apparent difference between the air concentrations of pesticides measured at each location. Sixteen of the 18 PAHs analyzed were found above the detection limit. Phenanthrene, fluoranthene, pyrene, fluorene, chrysene, benzo(b)fluoranthene, and naphthalene were the only PAHs with average concentrations above 100 pg/m{sup 3}. Overall, the 300 Area had higher average PAH concentrations compared to the 200-East Area and the background location at Rattlesnake Springs; however, the air concentrations at the 300-Area also are influenced by sources on the Hanford Site and from nearby communities.« less

  6. Legionella species colonization of water distribution systems, pools and air conditioning systems in cruise ships and ferries.

    PubMed

    Goutziana, Georgia; Mouchtouri, Varvara A; Karanika, Maria; Kavagias, Antonios; Stathakis, Nikolaos E; Gourgoulianis, Kostantinos; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2008-11-24

    Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. Water systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. The 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH >/=7.8 and total plate count > or =400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of > or =0.2 mg/L inhibited colonization of Legionella spp. WDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members.

  7. Airborne contaminants during controlled residential fires.

    PubMed

    Fent, Kenneth W; Evans, Douglas E; Babik, Kelsey; Striley, Cynthia; Bertke, Stephen; Kerber, Steve; Smith, Denise; Horn, Gavin P

    2018-05-01

    In this study, we characterize the area and personal air concentrations of combustion byproducts produced during controlled residential fires with furnishings common in 21 st century single family structures. Area air measurements were collected from the structure during active fire and overhaul (post suppression) and on the fireground where personnel were operating without any respiratory protection. Personal air measurements were collected from firefighters assigned to fire attack, victim search, overhaul, outside ventilation, and command/pump operator positions. Two different fire attack tactics were conducted for the fires (6 interior and 6 transitional) and exposures were compared between the tactics. For each of the 12 fires, firefighters were paired up to conduct each job assignment, except for overhaul that was conducted by 4 firefighters. Sampled compounds included polycyclic aromatic hydrocarbons (PAHs), volatile organic compounds (VOCs, e.g., benzene), hydrogen cyanide (HCN), and particulate (area air sampling only). Median personal air concentrations for the attack and search firefighters were generally well above applicable short-term occupational exposure limits, with the exception of HCN measured from search firefighters. Area air concentrations of all measured compounds decreased after suppression. Personal air concentrations of total PAHs and benzene measured from some overhaul firefighters exceeded exposure limits. Median personal air concentrations of HCN (16,300 ppb) exceeded the exposure limit for outside vent firefighters, with maximum levels (72,900 ppb) higher than the immediately dangerous to life and health (IDLH) level. Median air concentrations on the fireground (including particle count) were above background levels and highest when collected downwind of the structure and when ground-level smoke was the heaviest. No statistically significant differences in personal air concentrations were found between the 2 attack tactics. The results underscore the importance of wearing self-contained breathing apparatus when conducting overhaul or outside ventilation activities. Firefighters should also try to establish command upwind of the structure fire, and if this cannot be done, respiratory protection should be considered.

  8. Elemental analysis of size-fractionated particulate matter sampled in Göteborg, Sweden

    NASA Astrophysics Data System (ADS)

    Wagner, Annemarie; Boman, Johan; Gatari, Michael J.

    2008-12-01

    The aim of the study was to investigate the mass distribution of trace elements in aerosol samples collected in the urban area of Göteborg, Sweden, with special focus on the impact of different air masses and anthropogenic activities. Three measurement campaigns were conducted during December 2006 and January 2007. A PIXE cascade impactor was used to collect particulate matter in 9 size fractions ranging from 16 to 0.06 µm aerodynamic diameter. Polished quartz carriers were chosen as collection substrates for the subsequent direct analysis by TXRF. To investigate the sources of the analyzed air masses, backward trajectories were calculated. Our results showed that diurnal sampling was sufficient to investigate the mass distribution for Br, Ca, Cl, Cu, Fe, K, Sr and Zn, whereas a 5-day sampling period resulted in additional information on mass distribution for Cr and S. Unimodal mass distributions were found in the study area for the elements Ca, Cl, Fe and Zn, whereas the distributions for Br, Cu, Cr, K, Ni and S were bimodal, indicating high temperature processes as source of the submicron particle components. The measurement period including the New Year firework activities showed both an extensive increase in concentrations as well as a shift to the submicron range for K and Sr, elements that are typically found in fireworks. Further research is required to validate the quantification of trace elements directly collected on sample carriers.

  9. Parenting Attitudes of Expectant Couples Associated with the Air Force

    DTIC Science & Technology

    1992-05-01

    child abuse . These factors are also associated with Air Force life. These inherent risk factors when coupled with negative or abusive parenting attitudes could lead to child abuse . Little attention has been given to parenting attitudes in the Air Force population. Data were collected from a convenience sample of 67 participants in either the new OB orientation classes or the prepared child birth classes at two Air Force bases in the Southwest. The instrument was the Adult-Adolescent Parenting Inventory

  10. Evaluation of methods for simultaneous collection and determination of nicotine and polynuclear aromatic hydrocarbons in indoor air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chuang, J.C.; Kuhlman, M.R.; Wilson, N.K.

    1990-05-01

    A study was performed to determine whether one sampling system and one analytical method can be used to collect and measure both polynuclear aromatic hydrocarbons (PAHs) and nicotine. PAH collection efficiencies for both XAD-2 and XAD-4 adsorbents were very similar, but nicotine collection efficiency was greater for XAD-4. Spiked perdeuterated PAHs were retained well in both adsorbents after exposure to more than 300 m{sup 3} of air. A two-step Soxhlet extraction, dichloromethane followed by ethyl acetate, was used to remove nicotine and PAHs from XAD-4. The extract was analyzed by positive chemical ionization or electron impact gas chromatography/mass spectrometry (GC/MS)more » to determine nicotine and PAHs. It is shown that one sampling system (quartz fiber filter and XAD-4 in series) and one analytical method (Soxhlet extraction and GC/MS) can be used for both nicotine and PAHs in indoor.« less

  11. SEMIVOLATILE ORGANIC ACIDS AND LEVOGLUCOSAN IN NEW YORK CITY AIR FOLLOWING 9/11/2001

    EPA Science Inventory

    Organic acid compounds and levoglucosan, an important molecular marker of burning cellulose, are detected in New York City air collected between 9/26/01 and 10/24/01 500 m from Ground Zero. Sampling of Ground Zero emissions at our site is commensurate with a southwesterly wind f...

  12. Spore trap analysis and MSQPCR in evaluating mold burden: a flooded gymnasium case study

    EPA Science Inventory

    A school gymnasium was accidentally flooded by the fire-suppression sprinkler system. The surface water was removed but after 25 days, the school decided to evaluate whether there was any mold growth in the gymnasium. Thirty, five-minute air samples (75 m3 air) were collected w...

  13. Atmospheric Sampling on Ascension Island Using Multirotor UAVs

    PubMed Central

    Greatwood, Colin; Richardson, Thomas S.; Freer, Jim; Thomas, Rick M.; MacKenzie, A. Rob; Brownlow, Rebecca; Lowry, David; Fisher, Rebecca E.; Nisbet, Euan G.

    2017-01-01

    As part of an NERC-funded project investigating the southern methane anomaly, a team drawn from the Universities of Bristol, Birmingham and Royal Holloway flew small unmanned multirotors from Ascension Island for the purposes of atmospheric sampling. The objective of these flights was to collect air samples from below, within and above a persistent atmospheric feature, the Trade Wind Inversion, in order to characterise methane concentrations and their isotopic composition. These parameters allow the methane in the different air masses to be tied to different source locations, which can be further analysed using back trajectory atmospheric computer modelling. This paper describes the campaigns as a whole including the design of the bespoke eight rotor aircraft and the operational requirements that were needed in order to collect targeted multiple air samples up to 2.5 km above the ground level in under 20 min of flight time. Key features of the system described include real-time feedback of temperature and humidity, as well as system health data. This enabled detailed targeting of the air sampling design to be realised and planned during the flight mission on the downward leg, a capability that is invaluable in the presence of uncertainty in the pre-flight meteorological data. Environmental considerations are also outlined together with the flight plans that were created in order to rapidly fly vertical transects of the atmosphere whilst encountering changing wind conditions. Two sampling campaigns were carried out in September 2014 and July 2015 with over one hundred high altitude sampling missions. Lessons learned are given throughout, including those associated with operating in the testing environment encountered on Ascension Island. PMID:28545231

  14. SNIFFER: An aerial platform for the plume phase of a nuclear emergency

    NASA Astrophysics Data System (ADS)

    Castelluccio, D. M.; Cisbani, E.; Frullani, S.

    2012-04-01

    When a nuclear or radiological accident results in a release of a radioactive plume, AGS (Aerial Gamma Spectrometry) systems used in many countries, equipped with passive detectors, can help in giving quantitative assessment on the radiological situation (land surface contamination level) only when the air contamination due to the passage of the travelling plume has become negligible. To overcome this limitation, the Italian Institute of Health has developed and implemented a multi purpose air sampling system based on a fixed wing aircraft, for time-effective, large areas radiological surveillance (to face radiological emergency and to support homeland security). A fixed wing aircraft (Sky Arrow 650) with the front part of the fuselage properly adapted to house the detection equipment has been equipped with a compact air sampling line where the isokinetic sampling is dynamically maintained. Aerosol is collected on a Teflon® filter positioned along the line and hosted on a rotating 4-filters disk. A complex of detectors allows radionuclide identification in the collected aerosol samples. A correlated analysis of these two detectors data allows a quantitative measurement of air as well as ground surface concentration of gamma emitting radioisotopes. Environmental sensors and a GPS receiver support the characterization of the sampling conditions and the temporal and geolocation of the acquired data. Acquisition and control system based on compact electronics and real time software that operate the sampling line actuators, guarantee the dynamical isokinetic condition, and acquire the detectors and sensor data. The system is also equipped with other sampling lines to provide information on the concentration of other chemical pollutants. Operative flights have been carried out in the last years, and performances and results are presented.

  15. Pettit uses a Grab Sample Container in the FGB during Expedition Six

    NASA Image and Video Library

    2003-01-22

    ISS006-E-20835 (22 January 2003) --- Astronaut Donald R. Pettit, Expedition 6 NASA ISS science officer, holds a Grab Sample Container (GSC) in the functional cargo block (FGB), or Zarya, on the International Space Station (ISS). GSC is used for collecting air samples as part of ISS environmental monitoring.

  16. Pettit uses a Grab Sample Container in the U.S. Laboratory during Expedition Six

    NASA Image and Video Library

    2003-01-22

    ISS006-E-20834 (22 January 2003) --- Astronaut Donald R. Pettit, Expedition Six NASA ISS science officer, holds a Grab Sample Container (GSC) in the Destiny laboratory on the International Space Station (ISS). GSC is used for collecting air samples as part of ISS environmental monitoring.

  17. Passive Sampling for Indoor and Outdoor Exposures to Chlorpyrifos, Azinphos-Methyl, and Oxygen Analogs in a Rural Agricultural Community.

    PubMed

    Gibbs, Jenna L; Yost, Michael G; Negrete, Maria; Fenske, Richard A

    2017-03-01

    Recent studies have highlighted the increased potency of oxygen analogs of organophosphorus pesticides. These pesticides and oxygen analogs have previously been identified in the atmosphere following spray applications in the states of California and Washington. We used two passive sampling methods to measure levels of the ollowing organophosphorus pesticides: chlorpyrifos, azinphos-methyl, and their oxygen analogs at 14 farmworker and 9 non-farmworker households in an agricultural region of central Washington State in 2011. The passive methods included polyurethane foam passive air samplers deployed outdoors and indoors and polypropylene deposition plates deployed indoors. We collected cumulative monthly samples during the pesticide application seasons and during the winter season as a control. Monthly outdoor air concentrations ranged from 9.2 to 199 ng/m 3 for chlorpyrifos, 0.03 to 20 ng/m 3 for chlorpyrifos-oxon, < LOD (limit of detection) to 7.3 ng/m 3 for azinphos-methyl, and < LOD to 0.8 ng/m 3 for azinphos-methyl-oxon. Samples from proximal households (≤ 250 m) had significantly higher outdoor air concentrations of chlorpyrifos, chlorpyrifos-oxon, and azinphos-methyl than did samples from nonproximal households ( p ≤ 0.02). Overall, indoor air concentrations were lower than outdoors. For example, all outdoor air samples for chlorpyrifos and 97% of samples for azinphos-methyl were > LOD. Indoors, only 78% of air samples for chlorpyrifos and 35% of samples for azinphos-methyl were > LOD. Samples from farmworker households had higher indoor air concentrations of both pesticides than did samples from non-farmworker households. Mean indoor and outdoor air concentration ratios for chlorpyrifos and azinphos-methyl were 0.17 and 0.44, respectively. We identified higher levels in air and on surfaces at both proximal and farmworker households. Our findings further confirm the presence of pesticides and their oxygen analogs in air and highlight their potential for infiltration of indoor living environments. Citation: Gibbs JL, Yost MG, Negrete M, Fenske RA. 2017. Passive sampling for indoor and outdoor exposures to chlorpyrifos, azinphos-methyl, and oxygen analogs in a rural agricultural community. Environ Health Perspect 125:333-341; http://dx.doi.org/10.1289/EHP425.

  18. Assessment of depleted uranium in South-Western Iran.

    PubMed

    Yousefi, Hossein; Najafi, Abdullah

    2013-10-01

    Depleted uranium (DU) has been used in a number of conflicts most notably during the Gulf War in Iraq and existence of it has been reported in Kuwait by IAEA experts. Due to heavy sand storms prevailing into the direction to South West of Iran transporting sand originating from Iraq, the probability that DU could be moved is considered high. Therefore it was decided to take some air and soil samples near border line and some nearest cities. The study was focused on finding DU in air and soil of these south-west provinces. 22 air samples and 20 soil samples were collected and analyzed on their contents of uranium isotopes by alpha, beta and gamma spectrometry. The air and soil samples have been measured by use of an alpha-beta counter and by a gamma spectrometer, respectively. Results showed that there is no radiation impact from DU and so no DU has been transported via sand storms since all results were obtained below the detection limit. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Air filtration systems and restrictive access conditions improve indoor air quality in clinical units: Penicillium as a general indicator of hospital indoor fungal levels.

    PubMed

    Araujo, Ricardo; Cabral, João Paulo; Rodrigues, Acácio Gonçalves

    2008-03-01

    High-efficiency particulate air (HEPA) filters do not completely prevent nosocomial fungal infections. The first aim of this study was to evaluate the impact of different filters and access conditions upon airborne fungi in hospital facilities. Additionally, this study identified fungal indicators of indoor air concentrations. Eighteen rooms and wards equipped with different air filter systems, and access conditions were sampled weekly, during 16 weeks. Tap water samples were simultaneously collected. The overall mean concentration of atmospheric fungi for all wards was 100 colony forming units/m(3). We found a direct proportionality between the levels of the different fungi in the studied atmospheres. Wards with HEPA filters at positive air flow yielded lower fungal levels. Also, the existence of an anteroom and the use of protective clothes were associated to the lowest fungal levels. Principal component analysis showed that penicillia afforded the best separation between wards' air fungal levels. Fungal strains were rarely recovered from tap water samples. In addition to air filtration systems, some access conditions to hospital units, like presence of anteroom and use of protective clothes, may prevent high fungal air load. Penicillia can be used as a general indicator of indoor air fungal levels at Hospital S. João.

  20. Atmospheric Carbon Dioxide Record from Flask Measurements at Lampedusa Island (May 1992- December 2000)

    DOE Data Explorer

    Chamard, Paolo [ENEA, GEM-CLIM, Rome, Italy; Ciattaglia, Luigi [ENEA, GEM-CLIM, Rome, Italy; di Sarra, Alcide [ENEA, GEM-CLIM, Rome, Italy; Monteleone, Francesco [ENEA, GEM-CLIM, Rome, Italy

    2001-01-01

    Lampedusa Station rests on a rocky seashore on the eastern tip of Lampedusa Island, located south of Sicily in the central Mediterranean Sea. Air samples at Lampedusa Station are collected each Friday in two pairs of 2-L glass flasks. Flasks are evacuated and then pressurized to 280-300 kPa with ambient air at the sampling site. Determinations of CO2 are made by using a Siemens Ultramat 5E nondispersive infrared gas analyzer. Water vapor is removed during the sampling process by means of a chemical trap (Magnesium Perchlorate). During the measurement, residual water vapor is removed by means of a cold trap at -70°C. From the inception of the monitoring program at Lampedusa Station, CO2-in-synthetic air calibration gases have been used. Values are relative to the dry air WMO mole fraction scale.

  1. An Intervention to Reduce Residential Insecticide Exposure during Pregnancy among an Inner-City Cohort

    PubMed Central

    Williams, Megan K.; Barr, Dana B.; Camann, David E.; Cruz, Linda A.; Carlton, Elizabeth J.; Borjas, Mejico; Reyes, Andria; Evans, Dave; Kinney, Patrick L.; Whitehead, Ralph D.; Perera, Frederica P.; Matsoanne, Stephen; Whyatt, Robin M.

    2006-01-01

    Background We previously reported widespread insecticide exposure during pregnancy among inner-city women from New York City. Here we report on a pilot intervention using integrated pest management (IPM) to reduce pest infestations and residential insecticide exposures among pregnant New York City African-American and Latina women (25 intervention and 27 control homes). Methods The IPM consisted of professional cleaning, sealing of pest entry points, application of low-toxicity pesticides, and education. Cockroach infestation levels and 2-week integrated indoor air samples were collected at baseline and one month postintervention. The insecticides detected in the indoor air samples were also measured in maternal and umbilical cord blood collected at delivery. Results Cockroach infestations decreased significantly (p = 0.016) after the intervention among intervention cases but not control households. Among the intervention group, levels of piperonyl butoxide (a pyrethroid synergist) were significantly lower in indoor air samples after the intervention (p = 0.016). Insecticides were detected in maternal blood samples collected at delivery from controls but not from the intervention group. The difference was significant for trans-permethrin (p = 0.008) and of borderline significance (p = 0.1) for cis-permethrin and 2-isopropoxyphenol (a propoxur metabolite). Conclusion To our knowledge, this is the first study to use biologic dosimeters of prenatal pesticide exposure for assessing effectiveness of IPM. These pilot data suggest that IPM is an effective strategy for reducing pest infestation levels and the internal dose of insecticides during pregnancy. PMID:17107853

  2. Air Quality and Road Emission Results for Fort Stewart, Georgia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirkham, Randy R.; Driver, Crystal J.; Chamness, Mickie A.

    2004-02-02

    The Directorate of Public Works Environmental & Natural Resources Division (Fort Stewart /Hunter Army Airfield) contracted with the Pacific Northwest National Laboratory (PNNL) to monitor particulate matter (PM) concentrations on Fort Stewart, Georgia. The purpose of this investigation was to establish a PM sampling network using monitoring equipment typically used in U.S. Environmental Protection Agency (EPA) ''saturation sampling'', to determine air quality on the installation. In this initial study, the emphasis was on training-generated PM, not receptor PM loading. The majority of PM samples were 24-hr filter-based samples with sampling frequency ranging from every other day, to once every sixmore » days synchronized with the EPA 6th day national sampling schedule. Eight measurement sites were established and used to determine spatial variability in PM concentrations and evaluate whether fluctuations in PM appear to result from training activities and forest management practices on the installation. Data collected to date indicate the average installation PM2.5 concentration is lower than that of nearby urban Savannah, Georgia. At three sites near the installation perimeter, analyses to segregate PM concentrations by direction of air flow across the installation boundary indicate that air (below 80 ft) leaving the installation contains less PM2.5 than that entering the installation. This is reinforced by the observation that air near the ground is cleaner on average than the air at the top of the canopy.« less

  3. Determination of tricresyl phosphate air contamination in aircraft.

    PubMed

    Denola, G; Hanhela, P J; Mazurek, W

    2011-08-01

    Monitoring of tricresyl phosphate (TCP) contamination of cockpit air was undertaken in three types of military aircraft [fighter trainer (FT), fighter bomber (FB), and cargo transport (CT) aircraft]. The aircraft had a previous history of pilot complaints about cockpit air contamination suspected to originate from the engine bleed air supply through the entry of aircraft turbine engine oil (ATO) into the engine compressor. Air samples were collected in flight and on the ground during engine runs using sorbent tubes packed with Porapak Q and cellulose filters. A total of 78 air samples were analysed, from 46 different aircraft, and 48 samples were found to be below the limit of detection. Nine incidents of smoke/odour were identified during the study. The concentrations of toxic o-cresyl phosphate isomers were below the level of detection in all samples. The highest total TCP concentration was 51.3 μg m(-3), while most were generally found to be <5 μg m(-3) compared with the 8-h time-weighted average exposure limit of 100 μg m(-3) for tri-o-cresyl phosphate. The highest concentrations were found at high engine power. Although TCP contamination of cabin/cockpit air has been the subject of much concern in aviation, quantitative data are sparse.

  4. Condenser-type diffusion denuders for the collection of sulfur dioxide in a cleanroom.

    PubMed

    Chang, In-Hyoung; Lee, Dong Soo; Ock, Soon-Ho

    2003-02-01

    High-efficiency condenser-type diffusion denuders of cylindrical and planar geometries are described. The film condensation of water vapor onto a cooled denuder surface can be used as a method for collecting water-soluble gases. By using SO(2) as the test gas, the planar design offers quantitative collection efficiency at air sampling rates up to 5 L min(-1). Coupled to ion chromatography, the limit of detection (LOD) for SO(2) is 0.014 ppbv with a 30-min successive analysis sequence. The method has been successfully applied to the analysis of temperature- and humidity-controlled cleanroom air.

  5. Ram-air sample collection device for a chemical warfare agent sensor

    DOEpatents

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  6. Screening system and method of using same

    DOEpatents

    Jones, David A; Gresham, Christopher A; Basiliere, Marc L; Spates, James J; Rodacy, Philip J

    2014-04-15

    An integrated apparatus and method for screening an object for a target material is provided. The integrated apparatus comprises a housing and an integrated screener. The housing is positionable adjacent the object, and has a channel therethrough. The integrated screener is positionable in the housing, and comprises a fan, at least one filter, a heater and an analyzer. The fan is for drawing air carrying particles and vapor through the channel of the housing. The filter(s) is/are positionable in the channel of the housing for passage of the air therethrough. The filter(s) comprise(s) at least one metal foam having a plurality of pores therein for collecting and adsorbing a sample from the particles and vapor passing therethrough. The heater is for applying heat to the at least one metal foam whereby the collected sample is desorbed from the metal foam. The analyzer detects the target material from the desorbed sample.

  7. The mutagenicity of indoor air particles in a residential pilot field study: Application and evaluation of new methodologies

    NASA Astrophysics Data System (ADS)

    Lewtas, Joellen; Goto, Sumio; Williams, Katherine; Chuang, Jane C.; Petersen, Bruce A.; Wilson, Nancy K.

    The mutagenicity of indoor air paniculate matter has been measured in a pilot field study of homes in Columbus, Ohio during the 1984 winter. The study was conducted in eight all natural-gas homes and two all electric homes. Paniculate matter and semi-volatile organic compounds were collected indoors using a medium volume sampler. A micro-forward mutation bioassay employing Salmonella typhimurium strain TM 677 was used to quantify the mutagenicity in solvent extracts of microgram quantities of indoor air particles. The mutagenicity was quantified in terms of both mutation frequency per mg of organic matter extracted and per cubic meter of air sampled. The combustion source variables explored in this study included woodburning in fireplaces and cigarette smoking. Homes in which cigarette smoking occurred had the highest concentrations of mutagenicity per cubic meter of air. The average indoor air mutagenicity per cubic meter was highly correlated with the number of cigarettes smoked. When the separate sampling periods in each room were compared, the mutagenicity in the kitchen samples was the most highly correlated with the number of cigarettes smoked.

  8. The role of open-air inhalatoria in the air quality improvement in spa towns.

    PubMed

    Burkowska-But, Aleksandra; Kalwasińska, Agnieszka; Brzezinska, Maria Swiontek

    2014-08-01

    The present study was aimed at evaluating microbiological contamination of air in Ciechocinek and Inowrocław - Polish lowland spa towns. Additionally, the impact of open-air inhalatoria on the quality of air was evaluated. Air samples were collected seasonally in the urban areas, in the recreation areas and in the vicinity of inhalatoria in both towns using impaction. The numbers of mesophilic bacteria, staphylococci, hemolytic bacteria and actinomycetes were determined on media according to the Polish Standard PN-86/Z-04111/02. The number of moulds was determined on media according to the Polish Standard PN-86/Z-04111/03. While the highest numbers of microorganisms were noted at the sites located in the urban areas, the lowest numbers were noted in the vicinity of the open-air inhalatoria. In all the investigated air samples the values of bioaerosol concentrations were below the recommended TLVs (≤ 5000 CFU×m(-3) for both bacteria and fungi in outdoor environments). Location of the sampling site was invariably a decisive factor in determining the number of microorganisms in the air. The aerosol which is formed in the open-air inhalatoria has a positive influence on microbiological air quality. Owing to a unique microclimate and low air contamination, Ciechocinek and Inowrocław comply with all necessary requirements set for health resorts specializing in treating upper respiratory tract infections.

  9. Air-sampling inlet contamination by aircraft emissions on the NASA CV-990 aircraft

    NASA Technical Reports Server (NTRS)

    Condon, E. P.; Vedder, J. F.

    1984-01-01

    Results of an experimental investigation of the contamination of air sampling inlets by aircraft emissions from the NASA CV-990 research aircraft are presented. This four-engine jet aircraft is a NASA facility used for many different atmospheric and meteorological experiments, as well as for developing spacecraft instrumentation for remote measurements. Our investigations were performed to provide information on which to base the selection of sampling locations for a series of multi-instrument missions for measuring tropospheric trace gases. The major source of contamination is the exhaust from the jet engines, which generate many of the same gases that are of interest in atmospheric chemistry, as well as other gases that may interfere with sampling measurements. The engine exhaust contains these gases in mixing ratios many orders of magnitude greater than those that occur in the clean atmosphere which the missions seek to quantify. Pressurized samples of air were collected simultaneously from a scoop located forward of the engines to represent clean air and from other multiport scoops at various aft positions on the aircraft. The air samples were analyzed in the laboratory by gas chromatography for carbon monoxide, an abundant combustion by-product. Data are presented for various scoop locations under various flight conditions.

  10. Air pollution, inflammation and preterm birth in Mexico City: study design and methods.

    PubMed

    O'Neill, Marie S; Osornio-Vargas, Alvaro; Buxton, Miatta A; Sánchez, Brisa N; Rojas-Bracho, Leonora; Castillo-Castrejon, Marisol; Mordhukovich, Irina B; Brown, Daniel G; Vadillo-Ortega, Felipe

    2013-03-15

    Preterm birth is one of the leading causes of perinatal mortality and is associated with long-term adverse health consequences for surviving infants. Preterm birth rates are rising worldwide, and no effective means for prevention currently exists. Air pollution exposure may be a significant cause of prematurity, but many published studies lack the individual, clinical data needed to elucidate possible biological mechanisms mediating these epidemiological associations. This paper presents the design of a prospective study now underway to evaluate those mechanisms in a cohort of pregnant women residing in Mexico City. We address how air quality may act together with other factors to induce systemic inflammation and influence the duration of pregnancy. Data collection includes: biomarkers relevant to inflammation in cervico-vaginal exudate and peripheral blood, along with full clinical information, pro-inflammatory cytokine gene polymorphisms and air pollution data to evaluate spatial and temporal variability in air pollution exposure. Samples are collected on a monthly basis and participants are followed for the duration of pregnancy. The data will be used to evaluate whether ambient air pollution is associated with preterm birth, controlling for other risk factors. We will evaluate which time windows during pregnancy are most influential in the air pollution and preterm birth association. In addition, the epidemiological study will be complemented with a parallel toxicology invitro study, in which monocytic cells will be exposed to air particle samples to evaluate the expression of biomarkers of inflammation. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Air pollution, inflammation and preterm birth in Mexico City: Study design and methods

    PubMed Central

    O’Neill, Marie S.; Osornio-Vargas, Alvaro; Buxton, Miatta A.; Sanchez, Brisa N.; Rojas-Bracho, Leonora; Castillo-Castrejon, Marisol; Mordhukovich, Irina B.; Brown, Daniel G.; Vadillo-Ortega, Felipe

    2012-01-01

    Preterm birth is one of the leading causes of perinatal mortality and is associated with long-term adverse health consequences for surviving infants. Preterm birth rates are rising worldwide, and no effective means for prevention currently exists. Air pollution exposure may be a significant cause of prematurity, but many published studies lack the individual, clinical data needed to elucidate possible biological mechanisms mediating these epidemiological associations. This paper presents the design of a prospective study now underway to evaluate those mechanisms in a cohort of pregnant women residing in Mexico City. We address how air quality may act together with other factors to induce systemic inflammation and influence the duration of pregnancy. Data collection includes: biomarkers relevant to inflammation in cervico-vaginal exudate and peripheral blood, along with full clinical information, pro-inflammatory cytokine gene polymorphisms and air pollution data to evaluate spatial and temporal variability in air pollution exposure. Samples are collected on a monthly basis and participants are followed for the duration of pregnancy. The data will be used to evaluate whether ambient air pollution is associated with preterm birth, controlling for other risk factors. We will evaluate which time windows during pregnancy are most influential in the air pollution and preterm birth association. In addition, the epidemiological study will be complemented with a parallel toxicology invitro study, in which monocytic cells will be exposed to air particle samples to evaluate the expression of biomarkers of inflammation. PMID:23177781

  12. Detection of Legionella spp. by a nested-PCR assay in air samples of a wastewater treatment plant and downwind distances in Isfahan

    PubMed Central

    Mirzaee, Seyyed Abbas; Nikaeen, Mahnaz; Hajizadeh, Yaghob; Nabavi, BiBi Fatemeh; Hassanzadeh, Akbar

    2015-01-01

    Background: Wastewater contains a variety of pathogens and bio -aerosols generated during the wastewater treatment process, which could be a potential health risk for exposed individuals. This study was carried out to detect Legionella spp. in the bio -aerosols generated from different processes of a wastewater treatment plant (WWTP) in Isfahan, Iran, and the downwind distances. Materials and Methods: A total of 54 air samples were collected and analyzed for the presence of Legionella spp. by a nested- polymerase chain reaction (PCR) assay. A liquid impingement biosampler was used to capture bio -aerosols. The weather conditions were also recorded. Results: Legionella were detected in 6% of the samples, including air samples above the aeration tank (1/9), belt filter press (1/9), and 250 m downwind (1/9). Conclusion: The result of this study revealed the presence of Legionella spp. in air samples of a WWTP and downwind distance, which consequently represent a potential health risk to the exposed individuals. PMID:25802817

  13. MEASUREMENTS OF AIR POLLUTANT BIOMARKERS WITH EXHALED BREATH TECHNIQUES

    EPA Science Inventory

    Use of exhaled breath condensate (EBC) has appeal as a noninvasive surrogate sample for lung-derived fluid. Additionally, EBC can be collected multiple times over the course of a study, unlike many other lung sampling techniques which can be performed fewer times. However validat...

  14. Detection and quantification of reactive oxygen species (ROS) in indoor air.

    PubMed

    Montesinos, V Nahuel; Sleiman, Mohamad; Cohn, Sebastian; Litter, Marta I; Destaillats, Hugo

    2015-06-01

    Reactive oxygen species (ROS), such as free radicals and peroxides, are environmental trace pollutants potentially associated with asthma and airways inflammation. These compounds are often not detected in indoor air due to sampling and analytical limitations. This study developed and validated an experimental method to sample, identify and quantify ROS in indoor air using fluorescent probes. Tests were carried out simultaneously using three different probes: 2',7'-dichlorofluorescin (DCFH) to detect a broad range of ROS, Amplex ultra Red® (AuR) to detect peroxides, and terephthalic acid (TPA) to detect hydroxyl radicals (HO(•)). For each test, air samples were collected using two impingers in series kept in an ice bath, containing each 10 mL of 50 mM phosphate buffer at pH 7.2. In tests with TPA, that probe was also added to the buffer prior to sampling; in the other two tests, probes and additional reactants were added immediately after sampling. The concentration of fluorescent byproducts was determined fluorometrically. Calibration curves were developed by reacting DCFH and AuR with known amounts of H2O2, and using known amounts of 2-hydroxyterephthalic acid (HTPA) for TPA. Low detection limits (9-13 nM) and quantification limits (18-22 nM) were determined for all three probes, which presented a linear response in the range 10-500 nM for AuR and TPA, and 100-2000 nM for DCFH. High collection efficiency (CE) and recovery efficiency (RE) were observed for DCFH (CE=RE=100%) and AuR (CE=100%; RE=73%) by sampling from a laboratory-developed gas phase H2O2 generator. Interference of co-occurring ozone was evaluated and quantified for the three probes by sampling from the outlet of an ozone generator. The method was demonstrated by sampling air emitted by two portable air cleaners: a strong ozone generator (AC1) and a plasma generator (AC2). High ozone levels emitted by AC1 did not allow for simultaneous determination of ROS levels due to high background levels associated with ozone decomposition in the buffer. However, emitted ROS were quantified at the outlet of AC2 using two of the three probes. With AuR, the concentration of peroxides in air emitted by the air cleaner was 300 ppt of H2O2 equivalents. With TPA, the HO(•) concentration was 47 ppt. This method is best suited to quantify ROS in the presence of low ozone levels. Published by Elsevier B.V.

  15. DNA damage in buccal mucosa cells of pre-school children exposed to high levels of urban air pollutants.

    PubMed

    Ceretti, Elisabetta; Feretti, Donatella; Viola, Gaia C V; Zerbini, Ilaria; Limina, Rosa M; Zani, Claudia; Capelli, Michela; Lamera, Rossella; Donato, Francesco; Gelatti, Umberto

    2014-01-01

    Air pollution has been recognized as a human carcinogen. Children living in urban areas are a high-risk group, because genetic damage occurring early in life is considered able to increase the risk of carcinogenesis in adulthood. This study aimed to investigate micronuclei (MN) frequency, as a biomarker of DNA damage, in exfoliated buccal cells of pre-school children living in a town with high levels of air pollution. A sample of healthy 3-6-year-old children living in Brescia, Northern Italy, was investigated. A sample of the children's buccal mucosa cells was collected during the winter months in 2012 and 2013. DNA damage was investigated using the MN test. Children's exposure to urban air pollution was evaluated by means of a questionnaire filled in by their parents that included items on various possible sources of indoor and outdoor pollution, and the concentration of fine particulate matter (PM10, PM2.5) and NO2 in the 1-3 weeks preceding biological sample collection. 181 children (mean age ± SD: 4.3 ± 0.9 years) were investigated. The mean ± SD MN frequency was 0.29 ± 0.13%. A weak, though statistically significant, association of MN with concentration of air pollutants (PM10, PM2.5 and NO2) was found, whereas no association was apparent between MN frequency and the indoor and outdoor exposure variables investigated via the questionnaire. This study showed a high MN frequency in children living in a town with heavy air pollution in winter, higher than usually found among children living in areas with low or medium-high levels of air pollution.

  16. [Determination a variety of acidic gas in air of workplace by Ion Chromatography].

    PubMed

    Li, Shiyong

    2014-10-01

    To establish a method for determination of a variety of acid gas in the workplace air by Ion Chromatography. (hydrofluoric acid, hydrogen chloride or hydrochloric acid, sulfur anhydride or sulfuric acid, phosphoric acid, oxalic acid). The sample in workplace air was collected by the porous glass plate absorption tube containing 5 ml leacheate. (Sulfuric acid fog, phosphoric acid aerosol microporous membrane after collection, eluted with 5 ml of eluent.) To separated by AS14+AG14 chromatography column, by carbonate (2.0+1.0) mmol/L (Na(2)CO(3)-NaHCO(3)) as eluent, flow rate of 1 ml/min, then analyzed by electrical conductivity detector. The retain time was used for qualitative and the peak area was used for quantitation. The each ion of a variety of acid gas in the air of workplace were excellent in carbonate eluent separation. The linear range of working curve of 0∼20 mg/L. The correlation coefficient r>0.999; lower detection limit of 3.6∼115 µg/L; quantitative limit of 0.012∼0.53 mg/L; acquisition of 15L air were measured, the minimum detection concentration is 0.004 0∼0.13 mg/m(3). The recovery rate is 99.7%∼101.1%. In the sample without mutual interference ions. Samples stored at room temperature for 7 days. The same analysis method, the detection of various acidic gases in the air of workplace, simple operation, good separation effect, high sensitivity, high detection efficiency, easy popularization and application.

  17. Predictors of Indoor Air Concentrations in Smoking and Non-Smoking Residences

    PubMed Central

    Héroux, Marie-Eve; Clark, Nina; Van Ryswyk, Keith; Mallick, Ranjeeta; Gilbert, Nicolas L.; Harrison, Ian; Rispler, Kathleen; Wang, Daniel; Anastassopoulos, Angelos; Guay, Mireille; MacNeill, Morgan; Wheeler, Amanda J.

    2010-01-01

    Indoor concentrations of air pollutants (benzene, toluene, formaldehyde, acetaldehyde, acrolein, nitrogen dioxide, particulate matter, elemental carbon and ozone) were measured in residences in Regina, Saskatchewan, Canada. Data were collected in 106 homes in winter and 111 homes in summer of 2007, with 71 homes participating in both seasons. In addition, data for relative humidity, temperature, air exchange rates, housing characteristics and occupants’ activities during sampling were collected. Multiple linear regression analysis was used to construct season-specific models for the air pollutants. Where smoking was a major contributor to indoor concentrations, separate models were constructed for all homes and for those homes with no cigarette smoke exposure. The housing characteristics and occupants’ activities investigated in this study explained between 11% and 53% of the variability in indoor air pollutant concentrations, with ventilation, age of home and attached garage being important predictors for many pollutants. PMID:20948949

  18. Near-infrared spectroscopy (NIRS) as a tool to monitor exhaust air from poultry operations.

    PubMed

    Druckenmüller, Katharina; Günther, Klaus; Elbers, Gereon

    2018-07-15

    Intensive poultry operation systems emit a considerable volume of inorganic and organic matter in the surrounding environment. Monitoring cleaning properties of exhaust air cleaning systems and to detect small but significant changes in emission characteristics during a fattening cycle is important for both emission and fattening process control. In the present study, we evaluated the potential of near-infrared spectroscopy (NIRS) combined with chemometric techniques as a monitoring tool of exhaust air from poultry operation systems. To generate a high-quality data set for evaluation, the exhaust air of two poultry houses was sampled by applying state-of-the-art filter sampling protocols. The two stables were identical except for one crucial difference, the presence or absence of an exhaust air cleaning system. In total, twenty-one exhaust air samples were collected at the two sites to monitor spectral differences caused by the cleaning device, and to follow changes in exhaust air characteristics during a fattening period. The total dust load was analyzed by gravimetric determination and included as a response variable in multivariate data analysis. The filter samples were directly measured with NIR spectroscopy. Principal component analysis (PCA), linear discriminant analysis (LDA), and factor analysis (FA) were effective in classifying the NIR exhaust air spectra according to fattening day and origin. The results indicate that the dust load and the composition of exhaust air (inorganic or organic matter) substantially influence the NIR spectral patterns. In conclusion, NIR spectroscopy as a tool is a promising and very rapid way to detect differences between exhaust air samples based on still not clearly defined circumstances triggered during a fattening period and the availability of an exhaust air cleaning system. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  19. The nature of air pollution and the methods available for measuring it

    PubMed Central

    Ellison, J. McK.

    1965-01-01

    At present the principal sources of energy in Europe are coal and oil and fuels derived from them, and in European towns air pollution consists mainly of their combustion products. These combustion products naturally divide into two categories, gaseous and particulate, which are very different chemically and which behave very differently when they are near collecting surfaces; they therefore require very different techniques both for collecting and for estimating samples. Some methods of measurement, suitable for everyday routine use in Europe, are described; these offer a compromise between completeness and economy, and can help to give a general outline of the air pollution situation without undue complexity or prohibitive cost. PMID:14315712

  20. Spatial and seasonal distributions of polychlorinated dibenzo-p-dioxins and dibenzofurans and polychlorinated biphenyls around a municipal solid waste incinerator, determined using polyurethane foam passive air samplers.

    PubMed

    Gao, Lirong; Zhang, Qin; Liu, Lidan; Li, Changliang; Wang, Yiwen

    2014-11-01

    Twenty-six ambient air samples were collected around a municipal solid waste incinerator (MSWI) in the summer and winter using polyurethane foam passive air samplers, and analyzed to assess the spatial and seasonal distributions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs). Three stack gas samples were also collected and analyzed to determine PCDD/F (971 pg m(-3) in average) and PCB (2,671 pg m(-3) in average) emissions from the MSWI and to help identify the sources of the pollutants in the ambient air. The total PCDD/F concentrations in the ambient air samples were lower in the summer (472-1,223 fg m(-3)) than the winter (561-3913 fg m(-3)). In contrast, the atmospheric total PCB concentrations were higher in the summer (716-4,902 fg m(-3)) than the winter (489-2,298 fg m(-3)). Principal component analysis showed that, besides emissions from the MSWI, the domestic burning of coal and wood also contributed to the presence of PCDD/Fs and PCBs in the ambient air. The PCDD/F and PCB spatial distributions were analyzed using ordinary Kriging Interpolation and limited effect was found to be caused by emissions from the MSWI. Higher PCDD/F and PCB concentrations were observed downwind of the MSWI than in the other directions, but the highest concentrations were not to be found in the direction with the greatest wind frequency which might be caused by emissions from domestic coal and wood burning. We used a systemic method including sampling and data analysis method which can provide pioneering information for characterizing risks and assessing uncertainty of PCDD/Fs and PCBs in the ambient air around MSWIs in China. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Simple, miniaturized blood plasma extraction method.

    PubMed

    Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E

    2013-12-03

    A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to that observed with serum samples obtained by venipuncture.

  2. Airborne Detection of H5N8 Highly Pathogenic Avian Influenza Virus Genome in Poultry Farms, France.

    PubMed

    Scoizec, Axelle; Niqueux, Eric; Thomas, Rodolphe; Daniel, Patrick; Schmitz, Audrey; Le Bouquin, Sophie

    2018-01-01

    In southwestern France, during the winter of 2016-2017, the rapid spread of highly pathogenic avian influenza H5N8 outbreaks despite the implementation of routine control measures, raised the question about the potential role of airborne transmission in viral spread. As a first step to investigate the plausibility of that transmission, air samples were collected inside, outside and downwind from infected duck and chicken facilities. H5 avian influenza virus RNA was detected in all samples collected inside poultry houses, at external exhaust fans and at 5 m distance from poultry houses. For three of the five flocks studied, in the sample collected at 50-110 m distance, viral genomic RNA was detected. The measured viral air concentrations ranged between 4.3 and 6.4 log 10 RNA copies per m 3 , and their geometric mean decreased from external exhaust fans to the downwind measurement point. These findings are in accordance with the possibility of airborne transmission and question the procedures for outbreak depopulation.

  3. Airborne Detection of H5N8 Highly Pathogenic Avian Influenza Virus Genome in Poultry Farms, France

    PubMed Central

    Scoizec, Axelle; Niqueux, Eric; Thomas, Rodolphe; Daniel, Patrick; Schmitz, Audrey; Le Bouquin, Sophie

    2018-01-01

    In southwestern France, during the winter of 2016–2017, the rapid spread of highly pathogenic avian influenza H5N8 outbreaks despite the implementation of routine control measures, raised the question about the potential role of airborne transmission in viral spread. As a first step to investigate the plausibility of that transmission, air samples were collected inside, outside and downwind from infected duck and chicken facilities. H5 avian influenza virus RNA was detected in all samples collected inside poultry houses, at external exhaust fans and at 5 m distance from poultry houses. For three of the five flocks studied, in the sample collected at 50–110 m distance, viral genomic RNA was detected. The measured viral air concentrations ranged between 4.3 and 6.4 log10 RNA copies per m3, and their geometric mean decreased from external exhaust fans to the downwind measurement point. These findings are in accordance with the possibility of airborne transmission and question the procedures for outbreak depopulation. PMID:29487857

  4. Participant-based monitoring of indoor and outdoor nitrogen dioxide, volatile organic compounds, and polycyclic aromatic hydrocarbons among MICA-Air households

    NASA Astrophysics Data System (ADS)

    Johnson, Markey M.; Williams, Ron; Fan, Zhihua; Lin, Lin; Hudgens, Edward; Gallagher, Jane; Vette, Alan; Neas, Lucas; Özkaynak, Halûk

    2010-12-01

    The Mechanistic Indicators of Childhood Asthma (MICA) study in Detroit, Michigan introduced a participant-based approach to reduce the resource burden associated with collection of indoor and outdoor residential air sampling data. A subset of participants designated as MICA-Air conducted indoor and outdoor residential sampling of nitrogen dioxide (NO 2), volatile organic compounds (VOCs), and polycyclic aromatic hydrocarbons (PAHs). This participant-based methodology was subsequently adapted for use in the Vanguard phase of the U.S. National Children's Study. The current paper examines residential indoor and outdoor concentrations of these pollutant species among health study participants in Detroit, Michigan. Pollutants measured under MICA-Air agreed well with other studies and continuous monitoring data collected in Detroit. For example, NO 2 and BTEX concentrations reported for other Detroit area monitoring were generally within 10-15% of indoor and outdoor concentrations measured in MICA-Air households. Outdoor NO 2 concentrations were typically higher than indoor NO 2 concentration among MICA-Air homes, with a median indoor/outdoor (I/O) ratio of 0.6 in homes that were not impacted by environmental tobacco smoke (ETS) during air sampling. Indoor concentrations generally exceeded outdoor concentrations for VOC and PAH species measured among non-ETS homes in the study. I/O ratios for BTEX species (benzene, toluene, ethylbenzene, and m/p- and o-xylene) ranged from 1.2 for benzene to 3.1 for toluene. Outdoor NO 2 concentrations were approximately 4.5 ppb higher on weekdays versus weekends. As expected, I/O ratios pollutants were generally higher for homes impacted by ETS. These findings suggest that participant-based air sampling can provide a cost-effective alternative to technician-based approaches for assessing indoor and outdoor residential air pollution in community health studies. We also introduced a technique for estimating daily concentrations at each home by weighting 2- and 7-day integrated concentrations using continuous measurements from regulatory monitoring sites. This approach may be applied to estimate short-term daily or hourly pollutant concentrations in future health studies.

  5. Installation-restoration program. Phase 2. Confirmation/quantification. Stage 1 for Shaw Air Force Base, South Carolina. Final report, January 1984-October 1986

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexander, W.J.; Liddle, S.K.

    1986-09-01

    The primary objectives of this project were to collect and analyze groundwater, surface water, and sediment samples and to perform an initial characterization of the hydrogeochemical regime at potential contamination sites on Shaw Air Force Base near Sumter, South Carolina. This study constituted Phase II of the U.S. Air Force Installation Restoration Program (IRP). Five potential sources of groundwater pollution were studied. The evaluation primarily included the drilling of soil test borings, the installation, development, and sampling of groundwater monitoring wells, and the analyses of soil, surface water, and groundwater samples. Also used in the study were field measurements ofmore » water quality, water-level measurements site observations, published hydrogeologic data and Shaw AFB documents.« less

  6. Microbial Air Quality and Bacterial Surface Contamination in Ambulances During Patient Services

    PubMed Central

    Luksamijarulkul, Pipat; Pipitsangjan, Sirikun

    2015-01-01

    Objectives We sought to assess microbial air quality and bacterial surface contamination on medical instruments and the surrounding areas among 30 ambulance runs during service. Methods We performed a cross-sectional study of 106 air samples collected from 30 ambulances before patient services and 212 air samples collected during patient services to assess the bacterial and fungal counts at the two time points. Additionally, 226 surface swab samples were collected from medical instrument surfaces and the surrounding areas before and after ambulance runs. Groups or genus of isolated bacteria and fungi were preliminarily identified by Gram’s stain and lactophenol cotton blue. Data were analyzed using descriptive statistics, t-test, and Pearson’s correlation coefficient with a p-value of less than 0.050 considered significant. Results The mean and standard deviation of bacterial and fungal counts at the start of ambulance runs were 318±485cfu/m3 and 522±581cfu/m3, respectively. Bacterial counts during patient services were 468±607cfu/m3 and fungal counts were 656±612cfu/m3. Mean bacterial and fungal counts during patient services were significantly higher than those at the start of ambulance runs, p=0.005 and p=0.030, respectively. For surface contamination, the overall bacterial counts before and after patient services were 0.8±0.7cfu/cm2 and 1.3±1.1cfu/cm2, respectively (p<0.001). The predominant isolated bacteria and fungi were Staphylococcus spp. and Aspergillus spp., respectively. Additionally, there was a significantly positive correlation between bacterial (r=0.3, p<0.010) and fungal counts (r=0.2, p=0.020) in air samples and bacterial counts on medical instruments and allocated areas. Conclusions This study revealed high microbial contamination (bacterial and fungal) in ambulance air during services and higher bacterial contamination on medical instrument surfaces and allocated areas after ambulance services compared to the start of ambulance runs. Additionally, bacterial and fungal counts in ambulance air showed a significantly positive correlation with the bacterial surface contamination on medical instruments and allocated areas. Further studies should be conducted to determine the optimal intervention to reduce microbial contamination in the ambulance environment. PMID:25960835

  7. Installation Restoration Program (IRP). Aircraft Parking Apron Area. Volume 1. 152nd Reconnaissance Group, Nevada Air National Guard, Reno-Cannon International Airport, Reno, Nevada

    DTIC Science & Technology

    1994-06-01

    Loeltz, 1964, Evaluation of Hydroeeology and Hydrochemistry of the Truckee Meadow Area. Washoe County. Nevada. U. S. Geological Survey, Water I Supply...was detected in water samples collected from all monitoring wells. A concentration of I 0.055 ppm for the water sample collected from monitoring well...MWO8 during the first round of sampling (MW08-(1)), exceeded the federal drinking water standard of 0.05 ppm. The I background concentration for lead

  8. Source apportionment with uncertainty estimates of fine particulate matter in Ostrava, Czech Republic using Positive Matrix Factorization

    EPA Science Inventory

    A 14-week investigation during a warm and cold seasons was conducted to improve understanding of air pollution sources that might be impacting air quality in Ostrava, the Czech Republic. Fine particulate matter (PM2.5) samples were collected in consecutive 12-h day and night incr...

  9. Diesel Engine Air Emissions Reduction Technologies

    DTIC Science & Technology

    2010-04-01

    Hour GC/MS Gas Chromatography /Mass Spectroscopy GC/FID Gas Chromatography /Flame Ionization Detector g/mile Gram per Mile HAP Hazardous Air...Pollutant HC Hydrocarbon HPLC/UV High Performance Liquid Chromatography / Ultraviolet KPa Kilo-Pascals NDIR Non Dispersive Infrared... Chromatography (GC) where the samples were collected on DNPH cartridges. Portable versions of these instruments were available and employed for

  10. Levels, potential sources and human health risk of polycyclic aromatic hydrocarbons (PAHs) in particulate matter (PM(10)) in Kumasi, Ghana.

    PubMed

    Bortey-Sam, Nesta; Ikenaka, Yoshinori; Akoto, Osei; Nakayama, Shouta M M; Yohannes, Yared Beyene; Baidoo, Elvis; Mizukawa, Hazuki; Ishizuka, Mayumi

    2015-07-01

    Airborne particulate samples were collected on quartz filters to determine the concentrations, sources and health risks of polycyclic aromatic hydrocarbons (PAHs) in air in Kumasi, Ghana. A total of 32 air samples were collected in Kwame Nkrumah University of Science and Technology (KNUST) campus (pristine site) and city centre (CC). Samples were extracted with 1:2 v/v acetone/hexane mixture prior to GC-MS analyses. The sum of concentrations of 17 PAHs in air ranged from 0.51 to 16 (KNUST) and 19-38 ng/m(3) (CC). The concentration of benzo[a]pyrene, BaP, ranged from below detection limit to 0.08 ng/m(3) (KNUST) and 1.6 to 5.6 ng/m(3) (CC). Chemical mass balance model showed that PAHs in air in Kumasi were mainly from fuel combustion. The total BaP equivalent concentration (BaPeq) in CC was 18 times higher compared to KNUST; based on the European Legislation and Swedish and UK Standards for BaP in air, CC could be classified as highly polluted. Estimated carcinogenicity of PAHs in terms of BaPeq indicated that BaP was the principal PAH contributor in CC (70%). Health risk to adults and children associated with PAH inhalation was assessed by taking into account the lifetime average daily dose and corresponding incremental lifetime cancer risk (ILCR). The ILCR was within the acceptable range (10(-6) to 10(-4)), indicating low health risk to residents.

  11. Air toxics concentrations, source identification, and health risks: An air pollution hot spot in southwest Memphis, TN

    NASA Astrophysics Data System (ADS)

    Jia, Chunrong; Foran, Jeffery

    2013-12-01

    Southwest Memphis is a residential region surrounded by fossil fuel burning, steel, refining, and food processing industries, and considerable mobile sources whose emissions may pose adverse health risks to local residents. This study characterizes cancer and non-cancer risks resulting from exposure to ambient air toxics in southwest Memphis. Air toxics samples were collected at a central location every 6 days from June 5, 2008 to January 8, 2010. Volatile organic compounds (VOCs) were collected in evacuated stainless-steel canisters and aldehydes by DNPH cartridges, and samples were analyzed for 73 target compounds. A total of 60 compounds were detected and 39 were found in over 86% of the samples. Mean concentrations of many compounds were higher than those measured in many industrial communities throughout the U.S. The cumulative cancer risk associated with exposure to 13 carcinogens found in southwest Memphis air was 2.3 × 10-4, four times higher than the national average of 5.0 × 10-5. Three risk drivers were identified: benzene, formaldehyde, and acrylonitrile, which contributed 43%, 19%, and 14% to the cumulative risk, respectively. This is the first field study to confirm acrylonitrile as a potential risk driver. Mobile, secondary, industrial, and background sources contributed 57%, 24%, 14%, and 5% of the risk, respectively. The results of this study indicate that southwest Memphis, a region of significant income, racial, and social disparities, is also a region under significant environmental stress compared with surrounding areas and communities.

  12. Rapid, Automated Determination of Elemental Compositions of Ions in Mass Spectra Obtained with an Open-Air Ion Source (2 of 2)

    EPA Science Inventory

    An inexpensive autosampler for a DART/TOFMS provides mass spectra from analytes absorbed on 76 cotton swab, wipe samples in 7.5 min. A field sample carrier simplifies sample collection and provides swabs nearly ready for analysis to the lab. Applications of the high throughput pr...

  13. Identification of control parameters for the sulfur gas storability with bag sampling methods

    USDA-ARS?s Scientific Manuscript database

    Air samples containing sulfur compounds are often collected and stored in sample bags prior to analyses. The storage stability of six gaseous sulfur compounds (H2S, CH3SH, DMS, CS2, DMDS and SO2) was compared between two different bag materials (polyvinyl fluoride (PVF) and polyester aluminum (PEA))...

  14. Asbestos fiber release from the brake pads of overhead industrial cranes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spencer, J.W.; Plisko, M.J.; Balzer, J.L.

    The purpose of this evaluation was to determine the actual contribution of airborne asbestos fibers to the work environment from the operation of overhead cranes and hoists that use asbestos composition brake pads. The evaluation was conducted in a working manufacturing facility. Other potential sources of asbestos were accounted for by visual inspection and background air monitoring. An overhead crane assembly comprised of a trolley and two hoists was employed for this study. The crane was operated for two consecutive eight-hour shifts representative of a heavy-duty cycle. Forty-four personal and area air samples were collected during the assessment. Asbestos fibersmore » were analyzed for by phase contrast (NIOSH 7400), and transmission electron (NIOSH 7402) microscopy methods. Eight-hour time-weighted average (TWA) asbestos fiber concentrations ranges from <0.005 to 0.011 fibers/cc (PCM), and <0.0026 to <0.0094f/cc (TEM). There were no asbestos fibers detected by the TEM method from air samples collected during the operation of the cranes.« less

  15. Asbestos fiber release from the brake pads of overhead industrial cranes.

    PubMed

    Spencer, J W; Plisko, M J; Balzer, J L

    1999-06-01

    The purpose of this evaluation was to determine the actual contribution of airborne asbestos fibers to the work environment from the operation of overhead cranes and hoists that use asbestos composition brake pads. The evaluation was conducted in a working manufacturing facility. Other potential sources of asbestos were accounted for by visual inspection and background air monitoring. An overhead crane assembly comprised of a trolley and two hoists was employed for this study. The crane was operated for two consecutive eight-hour shifts representative of a heavy-duty cycle. Forty-four personal and area air samples were collected during the assessment. Asbestos fibers were analyzed for by phase contrast (NIOSH 7400), and transmission electron (NIOSH 7402) microscopy methods. Eight-hour time-weighted average (TWA) asbestos fiber concentrations ranged from < 0.005 to 0.011 fibers/cc (PCM), and < 0.0026 to < 0.0094 f/cc (TEM). There were no asbestos fibers detected by the TEM method from air samples collected during the operation of the cranes.

  16. US EPA Base Study Standard Operating Procedure for Sampling Volatile Organic Compounds in Indoor Air using Multisorbent Samplers

    EPA Pesticide Factsheets

    The objective of this procedure is to collect representative samples of volatile organic compound (VOC) contaminants present in indoor and outdoor environments using multisorbent samplers, and to subsequently analyze the concentration of VOCs, as selected by EPA.

  17. Mathematical estimation of the level of microbial contamination on spacecraft surfaces by volumetric air sampling

    NASA Technical Reports Server (NTRS)

    Oxborrow, G. S.; Roark, A. L.; Fields, N. D.; Puleo, J. R.

    1974-01-01

    Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model.

  18. Recent Rainfall and Aerosol Chemistry From Bermuda

    NASA Astrophysics Data System (ADS)

    Landing, W. M.; Shelley, R.; Kadko, D. C.

    2014-12-01

    This project was devoted to testing the use of Be-7 as a tracer for quantifying trace element fluxes from the atmosphere to the oceans. Rainfall and aerosol samples were collected between June 15, 2011 and July 27, 2013 at the Bermuda Institute of Ocean Sciences (BIOS) located near the eastern end of the island of Bermuda. Collectors were situated near ground level, clear of surrounding vegetation, at a meteorological monitoring station in front of the BIOS laboratory, about 10 m above sea level. This is a Bermuda Air Quality Program site used for ambient air quality monitoring. To quantify the atmospheric deposition of Be-7, plastic buckets were deployed for collection of fallout over ~3 week periods. Wet deposition was collected for trace element analysis using a specially modified "GEOTRACES" N-CON automated wet deposition collector. Aerosol samples were collected with a Tisch TE-5170V-BL high volume aerosol sampler, modified to collect 12 replicate samples on acid-washed 47mm diameter Whatman-41 filters, using procedures identical to those used for the US GEOTRACES aerosol program (Morton et al., 2013). Aerosol and rainfall samples were analyzed for total Na, Mg, Al, P, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Rb, Sr, Zr, Cd, Sb, Ba, La, Ce, Nd, Pb, Th, and U using ICPMS. Confirming earlier data from Bermuda, strong seasonality in rainfall and aerosol loading and chemistry was observed, particularly for aerosol and rainfall Fe concentrations when Saharan dust arrives in July/August with SE trajectories.

  19. Size selective isocyanate aerosols personal air sampling using porous plastic foams

    NASA Astrophysics Data System (ADS)

    Khanh Huynh, Cong; Duc, Trinh Vu

    2009-02-01

    As part of a European project (SMT4-CT96-2137), various European institutions specialized in occupational hygiene (BGIA, HSL, IOM, INRS, IST, Ambiente e Lavoro) have established a program of scientific collaboration to develop one or more prototypes of European personal samplers for the collection of simultaneous three dust fractions: inhalable, thoracic and respirable. These samplers based on existing sampling heads (IOM, GSP and cassettes) use Polyurethane Plastic Foam (PUF) according to their porosity to support sampling and separator size of the particles. In this study, the authors present an original application of size selective personal air sampling using chemical impregnated PUF to perform isocyanate aerosols capturing and derivatizing in industrial spray-painting shops.

  20. Rationale and Methods for Archival Sampling and Analysis of Atmospheric Trace Chemical Contaminants On Board Mir and Recommendations for the International Space Station

    NASA Technical Reports Server (NTRS)

    Perry, J. L.; James, J. T.; Cole, H. E.; Limero, T. F.; Beck, S. W.

    1997-01-01

    Collection and analysis of spacecraft cabin air samples are necessary to assess the cabin air quality with respect to crew health. Both toxicology and engineering disciplines work together to achieve an acceptably clean cabin atmosphere. Toxicology is concerned with limiting the risk to crew health from chemical sources, setting exposure limits, and analyzing air samples to determine how well these limits are met. Engineering provides the means for minimizing the contribution of the various contaminant generating sources by providing active contamination control equipment on board spacecraft and adhering to a rigorous material selection and control program during the design and construction of the spacecraft. A review of the rationale and objectives for sampling spacecraft cabin atmospheres is provided. The presently-available sampling equipment and methods are reviewed along with the analytical chemistry methods employed to determine trace contaminant concentrations. These methods are compared and assessed with respect to actual cabin air quality monitoring needs. Recommendations are presented with respect to the basic sampling program necessary to ensure an acceptably clean spacecraft cabin atmosphere. Also, rationale and recommendations for expanding the scope of the basic monitoring program are discussed.

  1. Long-Range Transport of Perchlorate Observed in the Atmospheric Aerosols Collected at Okinawa Island, Japan

    NASA Astrophysics Data System (ADS)

    Handa, D.; Okada, K.; Kuroki, Y.; Nakama, Y.; Nakajima, H.; Arakaki, T.; Tanahara, A.; Oomori, T.; Miyagi, T.; Kadena, H.; Ishizaki, T.; Nakama, F.

    2007-12-01

    The study of perchlorate has become quite active in the U.S. in the last several years. Perchlorate has been recognized as a new environmental pollutant and it attracted much attention quickly in the world. The health concern about perchlorate stems from the fact that it displaces iodide in the thyroid gland, while iodine-containing thyroid hormones are essential for proper neural development from the fetal stage through the first years of life. In this study, we determined the concentrations of perchlorate ion present in the atmospheric aerosols collected in Okinawa Island, Japan. We then examined the relationships between the perchlorate concentrations and the environmental parameters and the climatic conditions peculiar to Okinawa. Bulk aerosol samples were collected on quartz filters by using a high volume air sampler at Cape Hedo Atmosphere and Aerosol Monitoring Station (CHAAMS). Each sampling duration was one week. The quartz filters with aerosols were stirred with Milli-Q pure water for three hours before perchlorate ion was extracted. The extracted perchlorate ion concentrations were determined by ion chromatography (ICS-2000, DIONEX). The mean perchlorate concentration for the samples collected at CHAAMS was 1.83 ng/m3, and the minimum was 0.18 ng/m3. The samples collected during November 21-27, 2005, January 23-30, 2006 and April 24-01, 2006 had highest perchlorate concentrations. For these three samples, we performed back trajectory analysis, and found that the air mass for the three samples arrived from the Asian continent. A relatively strong correlation (r2 = 0.55) was found between perchlorate and nss-sulfate concentrations for the CHAAMS samples. Furthermore, we analyzed perchlorate in the soils and the fertilizers used for sugar cane farming around the CHAAMS area. The Milli-Q extract of the soil and the fertilizers did not contain any detectable levels of perchlorate ions. Therefore, it was suggested that perchlorate found in the atmospheric aerosols collected at CHAAMS was probably transported from the Asian continent.

  2. Site Environmental Report for 2009, Volume 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Suying

    2010-08-19

    Volume II of the Site Environmental Report for 2009 is provided by Ernest Orlando Lawrence Berkeley National Laboratory as a supplemental appendix to Volume I, which contains the body of the report. Volume II contains the environmental monitoring and sampling data used to generate summary results of routine and nonroutine sampling at the Laboratory, except for groundwater sampling data, which may be found in the reports referred to in Chapter 4 of Volume I. The results from sample collections are more comprehensive in Volume II than in Volume I: for completeness, all results from sample collections that began or endedmore » in calendar year (CY) 2009 are included in this volume. However, the samples representing CY 2008 data have not been used in the summary results that are reported in Volume I. (For example, although ambient air samples collected on January 6, 2009, are presented in Volume II, they represent December 2008 data and are not included in Table 4-2 in Volume I.) When appropriate, sampling results are reported in both conventional and International System (SI) units. For some results, the rounding procedure used in data reporting may result in apparent differences between the numbers reported in SI and conventional units. (For example, stack air tritium results reported as < 1.5 Bq/m3 are shown variously as < 39 and < 41 pCi/m3. Both of these results are rounded correctly to two significant digits.)« less

  3. [Bacterial contamination of the indoor air in a transplant unit].

    PubMed

    Matoušková, Ivanka; Holý, Ondřej

    2013-12-01

    For one year (August 2010 to July 2011), microbial contamination of the indoor air in the Transplant Unit of the Haemato-Oncology Clinic, Olomouc University Hospital was monitored monthly. Twenty sampling sites were singled out and a total of 240 indoor air samples were collected. An MAS-100 air sampler (Merck, GER) was used, air flow rate of 100 liters per minute, 1 minute. The measured values of indoor air temperature were stable. The relative air humidity ranged from 17% to 68%. The highest average value of microbial air contamination was found in the "staff entry room" (1170 CFU/m3). The lowest microbial air contamination (150-250 CFU/m3) was measured in the patient isolation units. The most frequently isolated bacterial strains were coagulase-negative staphylococci (94.3%), followed by Micrococcus spp. (67%) and Bacillus subtilis (11%). It can be assumed that the -source of these airborne bacterial strains are both patients and medical staff. They are classified as -opportunistic pathogens and as such can cause hospital infections among haemato-oncology patients.

  4. Occupational exposure to bisphenol A (BPA) in a plastic injection molding factory in Malaysia.

    PubMed

    Kouidhi, Wided; Thannimalay, Letchumi; Soon, Chen Sau; Ali Mohd, Mustafa

    2017-07-14

    The purpose of this study has been to assess ambient bisphenol A (BPA) levels in workplaces and urine levels of workers and to establish a BPA database for different populations in Malaysia. Urine samples were collected from plastic factory workers and from control subjects after their shift. Air samples were collected using gas analyzers from 5 sampling positions in the injection molding unit work area and from ambient air. The level of BPA in airborne and urine samples was quantified by the gas chromatography mass spectrometry - selected ion monitoring (GCMS-SIM) analysis. Bisphenol A was detected in the median range of 8-28.3 ng/m³ and 2.4-3.59 ng/m³ for the 5 sampling points in the plastic molding factory and in the ambient air respectively. The median urinary BPA concentration was significantly higher in the workers (3.81 ng/ml) than in control subjects (0.73 ng/ml). The urinary BPA concentration was significantly associated with airborne BPA levels (ρ = 0.55, p < 0.01). Our findings provide the first evidence that workers in a molding factory in Malaysia are occupationally exposed to BPA. Int J Occup Med Environ Health 2017;30(5):743-750. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  5. Delta14 CO2 Atmospheric Record from Schauinsland, Germany

    DOE Data Explorer

    Levin, Ingeborg [Institut fur Umweltphysik, University of Heidelberg, Heidelberg, Germany; Kromer, Bernd [Institut fur Umweltphysik, University of Heidelberg, Heidelberg, Germany

    1997-01-01

    All air samples at Schauinsland have been collected from a ventilated intake stack approximately 7m above the ground. Bi-weekly integrated CO2 samples from about 15-20 m3 of air have been continuously collected by dynamic quantitative absorption in carbonate-free sodium hydroxide (NaOH) solution. Air has been pumped through a rotating glass tube filled with a packed bed of Raschig rings (hard glass) to enlarge the surface of the absorbing NaOH solution (200 ml of 4 normal NaOH). The CO2 absorption is quantitative and samples represent mean values of 10 days to 2 weeks. In the laboratory, the samples are extracted from the NaOH solution in a vacuum system by adding hydrochloric or sulfuric acid. 13C analyses of the CO2 are by mass spectrometry and 14C analyses are by high precision proportional counting, after purification of the CO2 sample over charcoal (Schoch et al. 1980, Kromer and Münnich 1992). δ13C values are given relative to the V-PDB standard (Hut 1987) with the overall precision of a single analysis reported to be +/- 0.15 per mil (Levin and Kromer 1997). δ14C data are given relative to the NIST oxalic acid activity corrected for decay (Stuiver and Polach 1977) with the precision of a single δ14C measurement reported to be +/- 3-5 per mil (Levin and Kromer 1997).

  6. Spatial and temporal variations of chemicals in the TSP aerosols simultaneously collected at three islands in Okinawa, Japan

    NASA Astrophysics Data System (ADS)

    Arakaki, Takemitsu; Azechi, Sotaro; Somada, Yuka; Ijyu, Moriaki; Nakaema, Fumiya; Hitomi, Yuya; Handa, Daishi; Oshiro, Yoshito; Miyagi, Youichi; Tsuhako, Ai; Murayama, Hitomi; Higaonna, Yumi; Tanahara, Akira; Itoh, Akihide; Fukushima, Soko; Higashi, Kazuaki; Henza, Yui; Nishikawa, Rin; Shinjo, Hibiki; Wang, Hongyan

    2014-11-01

    East Asia's rapid economic growth has led to concerns about the emission of air pollutants. We collected total suspended particle (TSP) aerosol samples simultaneously at three islands in Okinawa, Japan, which are downwind of East Asia, during the Asian dust season, to examine the spatial and temporal variations and chemical transformations of major chemicals in the aerosols. Weekly samples were collected from July 2008 to June 2010, and the concentrations of water-soluble cations, anions, and organic carbon (WSOC) were determined (n = 303). Spatial distribution analysis showed that monthly mean concentrations of non-sea-salt (nss)-SO42- in the spring (Asian dust season) decreased with increasing distance from Asia, while the trend for NO3- was less evident, suggesting that chemical transformation affected the long-range transport of certain chemicals. Temporal variation analysis showed that concentrations of nss-SO42-, NO3-, and WSOC during the spring were about 2.0, 2.4, and 1.8 times those in the summer (cleaner air mass from the Pacific Ocean), respectively. This study demonstrated that air pollutants were transported from the Asian continent to the Okinawa islands and affected the air quality in the region. There may also be impacts on ecosystems, because increased concentrations of particulate NO3- could increase nutrient levels around the Okinawa islands.

  7. Evaluation of particulate air samplers for airborne aflatoxin B1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silas, J.C.; Harrison, M.A.; Carpenter, J.A.

    Five air samplers (Millipore, all-glass impinger, centrifugal, Andersen, and absorbent cotton) were evaluated for their ability to collect airborne grain particles contaminated with aflatoxin B1. Corn dust containing 100 micrograms aflatoxin B1/g was aerosolized within a containment system. Each device sampled 100 I air, thus exchanging the air in the chamber two times. Aflatoxin B1 was extracted from all sampling matrices and was detected and quantitated with thin-layer chromatography and scanning fluorodensitometry. The highest efficiency was obtained with the Millipore sampler, while the efficiencies of the centrifugal and the cotton samplers were almost identical. Efficiency of an Andersen was less,more » with no toxin recovered from an all-glass impinger. Measurement of particle size was accomplished with the Andersen sampler.« less

  8. Lithologic, natural-gamma, grain-size, and well-construction data for Wright-Patterson Air Force Base, Ohio

    USGS Publications Warehouse

    Dumouchelle, D.H.; De Roche, Jeffrey T.

    1991-01-01

    Wright-Patterson Air Force Base, in southwestern Ohio, overlies a buried-valley aquifer. The U.S. Geological Survey installed 35 observation wells at 13 sites on the base from fall 1988 through spring 1990. Fourteen of the wells were completed in bedrock; the remaining wells were completed in unconsolidated sediments. Split-spoon and bedrock cores were collected from all of the bedrock wells. Shelby-tube samples were collected from four wells. The wells were drilled by either the cable-tool or rotary method. Data presented in this report include lithologic and natural-gamma logs, and, for selected sediment samples, grain-size distributions of permeability. Final well-construction details, such as the total depth of well, screened interval, and grouting details, also are presented.

  9. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF SOIL OR HOUSE DUST SAMPLES USING CHLORPYRIFOS ELISA SAMPLES (BCO-L-1.0)

    EPA Science Inventory

    This abstract is included for completeness of documentation, but this SOP was not used in the study.

    The purpose of this SOP is to describe the procedures for analyzing both Stage II and Stage III soil and vacuum-cleaner collected house dust samples, and Stage III air samples u...

  10. Polycyclic aromatic hydrocarbons in a bakery indoor air: trends, dynamics, and dispersion.

    PubMed

    Ielpo, Pierina; Taurino, Maria Rosaria; Buccolieri, Riccardo; Placentino, Claudia Marcella; Gallone, Francesco; Ancona, Valeria; Di Sabatino, Silvana

    2018-02-27

    Indoor air pollution assessment in work environments remains challenging due to a combination of logistic reasons and availability of costly instrumentation for data acquisition and post-processing. Existing literature focuses on energy production environments, hospitals, and less so on food production spaces. Studies on indoor air quality in bakeries are scarce or even absent. Motivated by this, the present study investigates indoor air quality in a bakery located in Bari province in South Italy, using a combination of approaches including analytical chemistry analyses and computational fluid dynamics to reconstruct the air ventilation in response to air temperature gradients within the working environment. PM 2.5 indoor samplings were collected every 6 h from 7 to 19 April 2013 in the proximity of two bakery ovens powered by gas and wood, respectively. For each sampling day, 4 PM 2.5 samples were collected: from 3:00 to 9:00 h (first), from 9:00 to 13:30 h (second), from 14:00 to 21:00 h (third), and from 21:00 to 3:00 h (fourth). In total, 40 samples were collected. On each sample, several polycyclic aromatic hydrocarbons (PAHs) were determined such as benzo[a]anthracene (228), benzo[b]fluoranthene (252), benzo[k]fluoranthene (252), benzo[a]pyrene (252), benzo[g,h,i]perylene (276), indeno[1,2,3-cd]pyrene (276), and dibenzo[a,h]anthracene (278), the main compounds of 16 priority US Environmental Protection Agency (US-EPA) PAHs in particulate phase. The PAH mean concentrations showed higher values during the first (from 3:00 to 9:00 h) and fourth (from 21:00 to 3:00 h) sampling intervals than the other two with benzo[a]pyrene mean values exceeding the Italian law limit of 1 ng/m 3 . Taking into account benzo[a]pyrene mean concentration for the first interval and the first plus the second one, which are the hours with the largest working activity, we have estimated that the baker and co-workers are exposed to a cancer risk of 4.3 × 10 -7 and 5.8 × 10 -7 , respectively (these values are lower than US-EPA recommended guideline of 10 -6 ). Our study was complemented by numerical analyses using state-of-the-art computational fluid dynamics to reconstruct at high resolution air movement from the various working places, i.e., the bakery and the selling area which were connected via a door. The numerical simulations were possible given that surface temperature using infrared thermography as well as air temperature was continuously recorded throughout the sampling acquisition. The use of this approach allowed us to estimate the transport and diffusion of benzo[a]pyrene from one area to the other thus complementing the point sampling information. Computational fluid dynamic simulation results confirm the presence of benzo[a]pyrene in the laboratory as obtained from the measurements and suggests its presence in the sales' area of the bakery with concentrations similar those found in the laboratory.

  11. Characterization of Dust on Solar Devices in Southern Nevada =

    NASA Astrophysics Data System (ADS)

    Sylva, Jason R.

    Dust can impact the efficiency of solar energy collection devices, and in some arid environments, dust can reduce solar energy efficiency up to 30%. Reducing the impact of dust is therefore critical in the expansion of solar technology throughout regions where solar energy is utilized. Characterization of suspended and settled particulate matter can assist in developing strategies for dust mitigation. With the characterization of suspended and settled particulate in remote, rural, and urban environments, more informed decisions can be made regarding the selection of coating material on solar panels as well as developing cleaning and maintenance procedures. Particulate matter that deposits on a solar surface can potentially interact with solar radiation, precipitation, or even directly with the surface material itself. These interactions could lead to the formation of coatings that reduce/block radiation and/or degrade the integrity of the surface. When you extrapolate these possibilities to a larger scale preliminary characterization of dust will play a vital role when planning the construction of a solar energy facility. A variety of sampling techniques were employed to obtain particulate matter for characterization. These included direct collection of particulates from solar surfaces: via vacuum and wipe sample collection on panels, tacky dot adhesive slides and plain slides that were exposed at different intervals, desert vugs that are natural particulate collectors, as well as high volume air sampling for collection of suspended particulates. High volume air sampling was performed using glass fiber filters and 2 micron stainless steel screens. Direct collection of settled particulates was performed by sampling from solar surfaces, vugs, and by collection on exposed glass surfaces. Collection onto glass surfaces was achieved by setting up a plain microscope slide, tacky dot slides, and panes of glass. The sampling methodology allowed for the collection of samples for analyses using various analytical methods that included Raman microspectroscopy, pyrolysis gas chromatography mass spectrometry, ion chromatography and inductively coupled plasma mass spectrometry. These various methods allow for identification of organic and inorganic components as well the mineral distribution of suspended and settled particulate material. None None None None None

  12. Trichocomaceae: biodiversity of Aspergillus spp and Penicillium spp residing in libraries.

    PubMed

    Leite, Diniz Pereira; Yamamoto, Ana Caroline Akeme; Amadio, Janaína Vasconcellos Ribeiro de Souza; Martins, Evelin Rodrigues; do Santos, Fábio Alexandre Leal; Simões, Sara de Almeida Alves; Hahn, Rosane Christine

    2012-10-19

    Atmospheric air is the most common vehicle for the dispersion of fungi. Fungi belonging to the genera Aspergillus and Penicillium are cosmopolitan and are classified in the family Trichocomaceae. Species of the genera are commonly found in soil, decaying organic materials, animal feed, stored grains, and other materials. This study aimed to determine the taxonomic diversity of airborne fungi of the genera Aspergillus and Penicillium residing in the dust of library environments to contribute to current knowledge of these characteristic genera. Three libraries in the city of Cuiaba, State of Mato Grosso, Brazil, were selected as the study areas. A total of 168 samples were collected at randomized sites within each library in areas containing journals, archives, in study rooms, and in collection storage areas in two different periods, the dry season (n = 42)  and the rainy season (n = 42). Samples were collected by exposing Petri dishes containing Sabouraud agar with chloramphenicol to the environmental air. Additional samples were collected with sterile swabs which were rubbed over the surface of randomly chosen books on the shelves; the swabs were subsequently incubated in the laboratory. The genus Aspergillus was highlighted as one of the principal airborne fungi present in indoor environments. Aspergillus spp was identified in 1,277 (89.6%) samples and Penicillium spp in 148 (10.4%). The dry period exhibited a greater number of isolates of the two taxons.

  13. Microfluidic Air Sampler for Highly Efficient Bacterial Aerosol Collection and Identification.

    PubMed

    Bian, Xiaojun; Lan, Ying; Wang, Bing; Zhang, Yu Shrike; Liu, Baohong; Yang, Pengyuan; Zhang, Weijia; Qiao, Liang

    2016-12-06

    The early warning capability of the presence of biological aerosol threats is an urgent demand in ensuing civilian and military safety. Efficient and rapid air sample collection in relevant indoor or outdoor environment is a key step for subsequent analysis of airborne microorganisms. Herein, we report a portable battery-powered sampler that is capable of highly efficient bioaerosol collection. The essential module of the sampler is a polydimethylsiloxane (PDMS) microfluidic chip, which consisted of a 3-loop double-spiral microchannel featuring embedded herringbone and sawtooth wave-shaped structures. Vibrio parahemolyticus (V. parahemolyticus) as a model microorganism, was initially employed to validate the bioaerosol collection performance of the device. Results showed that the sampling efficacy reached as high as >99.9%. The microfluidic sampler showed greatly improved capturing efficiency compared with traditional plate sedimentation methods. The high performance of our device was attributed to the horizontal inertial centrifugal force and the vertical turbulence applied to airflow during sampling. The centrifugation field and turbulence were generated by the specially designed herringbone structures when air circulated in the double-spiral microchannel. The sawtooth wave-shaped microstructure created larger specific surface area for accommodating more aerosols. Furthermore, a mixture of bacterial aerosols formed by V. parahemolyticus, Listeria monocytogenes, and Escherichia coli was extracted by the microfluidic sampler. Subsequent integration with mass spectrometry conveniently identified the multiple bacterial species captured by the sampler. Our developed stand-alone and cable-free sampler shows clear advantages comparing with conventional strategies, including portability, easy-to-use, and low cost, indicating great potential in future field applications.

  14. Ground-Based Aerosol Measurements | Science Inventory ...

    EPA Pesticide Factsheets

    Atmospheric particulate matter (PM) is a complex chemical mixture of liquid and solid particles suspended in air (Seinfeld and Pandis 2016). Measurements of this complex mixture form the basis of our knowledge regarding particle formation, source-receptor relationships, data to test and verify complex air quality models, and how PM impacts human health, visibility, global warming, and ecological systems (EPA 2009). Historically, PM samples have been collected on filters or other substrates with subsequent chemical analysis in the laboratory and this is still the major approach for routine networks (Chow 2005; Solomon et al. 2014) as well as in research studies. In this approach, air, at a specified flow rate and time period, is typically drawn through an inlet, usually a size selective inlet, and then drawn through filters, 1 INTRODUCTION Atmospheric particulate matter (PM) is a complex chemical mixture of liquid and solid particles suspended in air (Seinfeld and Pandis 2016). Measurements of this complex mixture form the basis of our knowledge regarding particle formation, source-receptor relationships, data to test and verify complex air quality models, and how PM impacts human health, visibility, global warming, and ecological systems (EPA 2009). Historically, PM samples have been collected on filters or other substrates with subsequent chemical analysis in the laboratory and this is still the major approach for routine networks (Chow 2005; Solomo

  15. Evaluation of passive diffusion bag and dialysis samplers in selected wells at Hickam Air Force Base, Hawaii, July 2001

    USGS Publications Warehouse

    Vroblesky, Don A.; Pravecek, Tasha

    2002-01-01

    Field comparisons of chemical concentrations obtained from dialysis samplers, passive diffusion bag samplers, and low-flow samplers showed generally close agreement in most of the 13 wells tested during July 2001 at Hickam Air Force Base, Hawaii. The data for chloride, sulfate, iron, alkalinity, arsenic, and methane appear to show that the dialysis samplers are capable of accurately collecting a passive sample for these constituents. In general, the comparisons of volatile organic compound concentrations showed a relatively close correspondence between the two different types of diffusion samples and between the diffusion samples and the low-flow samples collected in most wells. Divergence appears to have resulted primarily from the pumping method, either producing a mixed sample or water not characteristic of aquifer water moving through the borehole under ambient conditions. The fact that alkalinity was not detected in the passive diffusion bag samplers, highly alkaline waters without volatilization loss from effervescence, which can occur when a sample is acidified for preservation. Both dialysis and passive diffusion bag samplers are relatively inexpensive and can be deployed rapidly and easily. Passive diffusion bag samplers are intended for sampling volatile organic compounds only, but dialysis samplers can be used to sample both volatile organic compounds and inorganic solutes. Regenerated cellulose dialysis samplers, however, are subject to biodegradation and probably should be deployed no sooner than 2 weeks prior to recovery. 1 U.S. Geological Survey, Columbia, South Carolina. 2 Air Florce Center for Environmental Excellence, San Antionio, Texas.

  16. Evaporative Cooler Use Influences Temporal Indoor Relative Humidity but Not Dust Mite Allergen Levels in Homes in a Semi-Arid Climate

    PubMed Central

    Johnston, James D.; Tuttle, Steven C.; Nelson, Morgan C.; Bradshaw, Rebecca K.; Hoybjerg, Taylor G.; Johnson, Julene B.; Kruman, Bryce A.; Orton, Taylor S.; Cook, Ryan B.; Eggett, Dennis L.; Weber, K. Scott

    2016-01-01

    Concerns about energy consumption and climate change make residential evaporative coolers a popular alternative to central air conditioning in arid and semi-arid climates. However, evaporative coolers have been shown to significantly increase indoor relative humidity and dust mite allergen levels in some studies, while showing no association in other studies. Improved measurement of temporal fluctuations in indoor relative humidity may help identify factors that promote mite growth in homes in dry climates. Dust samples and continuous indoor relative humidity measurements were collected from homes with central air conditioning and homes with evaporative coolers in Utah. Samples were collected over two seasons, winter/spring (Jan–Apr) and summer (July–Sept), 2014. Dust samples were analyzed for Der p 1 and Der f 1 using a two-site monoclonal antibody-based enzyme-linked immunosorbent assay (ELISA) analysis. Housing characteristics including age of home, occupant density, and age of mattresses, furniture, and carpeting were also measured. Positive Der p 1 or Der f 1 samples were found in 25.0% of the homes and there was no difference in mean allergen levels by type of air conditioning. Indoor relative humidity was significantly higher in homes with evaporative coolers compared to those with central air conditioning during the summer. Homes with evaporative coolers also spent significantly more time during summer above 55.0% and 65.0% relative humidity compared to central air homes, but not above 75.0%. Findings from this study suggest that increased humidity from evaporative coolers may not be sufficient to exceed the critical equilibrium humidity or maintain humidity excursions for sufficient duration in relatively larger single-family homes in semi-arid climates to support mite growth and reproduction. PMID:26808528

  17. Evaporative Cooler Use Influences Temporal Indoor Relative Humidity but Not Dust Mite Allergen Levels in Homes in a Semi-Arid Climate.

    PubMed

    Johnston, James D; Tuttle, Steven C; Nelson, Morgan C; Bradshaw, Rebecca K; Hoybjerg, Taylor G; Johnson, Julene B; Kruman, Bryce A; Orton, Taylor S; Cook, Ryan B; Eggett, Dennis L; Weber, K Scott

    2016-01-01

    Concerns about energy consumption and climate change make residential evaporative coolers a popular alternative to central air conditioning in arid and semi-arid climates. However, evaporative coolers have been shown to significantly increase indoor relative humidity and dust mite allergen levels in some studies, while showing no association in other studies. Improved measurement of temporal fluctuations in indoor relative humidity may help identify factors that promote mite growth in homes in dry climates. Dust samples and continuous indoor relative humidity measurements were collected from homes with central air conditioning and homes with evaporative coolers in Utah. Samples were collected over two seasons, winter/spring (Jan-Apr) and summer (July-Sept), 2014. Dust samples were analyzed for Der p 1 and Der f 1 using a two-site monoclonal antibody-based enzyme-linked immunosorbent assay (ELISA) analysis. Housing characteristics including age of home, occupant density, and age of mattresses, furniture, and carpeting were also measured. Positive Der p 1 or Der f 1 samples were found in 25.0% of the homes and there was no difference in mean allergen levels by type of air conditioning. Indoor relative humidity was significantly higher in homes with evaporative coolers compared to those with central air conditioning during the summer. Homes with evaporative coolers also spent significantly more time during summer above 55.0% and 65.0% relative humidity compared to central air homes, but not above 75.0%. Findings from this study suggest that increased humidity from evaporative coolers may not be sufficient to exceed the critical equilibrium humidity or maintain humidity excursions for sufficient duration in relatively larger single-family homes in semi-arid climates to support mite growth and reproduction.

  18. U.S. EPA response to the Fukushima Daiichi Nuclear Power Plant accident.

    PubMed

    Tupin, Edward A; Boyd, Michael A; Mosser, Jennifer E; Wieder, Jessica S

    2012-05-01

    During the spring of 2011, the U.S. Environmental Protection Agency (EPA) used its national radiation monitoring and sampling system, RadNet, to detect, identify, and inform the public about radioactive material in the United States resulting from Japan's Fukushima Daiichi Nuclear Power Plant release. The RadNet system monitors ambient air, drinking water, precipitation, and pasteurized milk for radionuclides. To supplement its existing stationary (fixed) continuous air monitoring system, EPA deployed additional air monitors to Saipan, Guam, and locations in the western United States. The Agency also accelerated the regular quarterly sampling of milk and drinking water and collected an additional round of samples. For two months, staff located at EPA's Headquarters Emergency Operations Center, west coast regional offices, and National Air and Radiation Environmental Lab worked seven days a week to handle the increased radiochemical sample analysis from air filters, precipitation, drinking water, and milk; provide interagency scientific input; and answer press and public inquiries. EPA's data was consistent with what was expected from the Fukushima Daiichi Nuclear Power Plant release. The levels of radioactivity were so low that the readings from the near-real-time RadNet air monitors stayed within normal background ranges. Detailed sample analyses were needed to identify the radionuclides associated with the release. Starting at the end of April and continuing through May 2011, levels of radioactive material decreased as expected.

  19. Heavy metal pollution in Nanchang City and its health implication on traffic policemen.

    PubMed

    Liu, Xiaozhen; Liang, Yue; Guo, Jiangmei

    2017-09-27

    The purpose of this study is to evaluate the health effect of heavy metal pollution in air pollutants on traffic policemen. This study will facilitate the scientific evaluation of health status of traffic policemen. PM 10 samples were collected from industrial area, congested traffic area and residential area respectively in Nanchang City, and the concentrations of heavy metals were analyzed. The traffic policemen were examined through chest X-rays. The total of 637 urine samples and 142 blood samples have been collected, and the concentrations of Pb in samples were detected. Vehicle flux data of Nanchang City were collected from the Department of Transport's Traffic Management. Statistic analyses were carried out by statistics software of Excel 2003 and SPSS20.0, and the health effect of heavy metal pollution of PM 10 on the traffic policemen was evaluated. The discharge of pollutants from enterprises is an important reason for the high content of heavy metals in urban air pollution. With the rapid growth of urban traffic flow, Bayi Bridge becomes an important transportation hinge in Nanchang City, and the bidirectional traffic flow rate through the bridge at peak hours reached 99 vehicles per minute. The latent hazard of occupational harm on the traffic policemen caused by automobile exhaust is increasing. The concentration of Pb in the urine and blood samples from traffic policemen working in Nanchang City was 268.310 ± 177.031 and 22.873 ± 21.137 μg/L, respectively. Both results (2.04% of Pb in urine and 18.31% of Pb in blood) exceeded the highest limit of observed occupationally outdoor workers. This study provides an initial contribution for the assessment of city air pollution, esp. the health effect of heavy metal (Pb) pollution on traffic policemen.

  20. Granulometric and magnetic properties of deposited particles in the Beijing subway and the implications for air quality management.

    PubMed

    Cui, Guipeng; Zhou, Liping; Dearing, John

    2016-10-15

    The subway system is an important traffic facility in Beijing and its internal air quality is an environmental issue that could potentially affect millions of people every day. Due to the intrinsic nature of rail abrasion in subway tunnels, iron-containing particles can be generated and become suspended in the subway environment. While some studies (e.g. Li et al., 2006) have monitored the in-train levels of PM2.5 (particles<2.5μm), there is a lack of systematic assessment of the concentration and characteristics of iron-containing particles in the Beijing subway system. Here we report results of a study on the granulometric and magnetic properties of deposited particle samples collected at different localities of the Beijing subway system. Our results show that the subway samples are characterized by the presence of fine particles. Volume proportions of 6.1±1.3% for particles<2.5μm and 27.5±6.1% for particles<10μm are found in the bulk subway samples. These samples exhibit a strong magnetic signal, which is approximately two orders of magnitude higher than that in naturally deposited particles collected in Beijing. Fine grained ferromagnetic and ferrimagnetic minerals (e.g. iron and magnetite, respectively) are identified from mineral magnetic measurements and scanning electric microscopy. The samples collected from the Beijing stations with platform screen doors are found to be magnetically stronger and finer than those without them, suggesting that platform screen doors have failed to block the fine iron-containing particles released from the rail tunnel. Given the potential health consequences of fine suspended iron-containing particles, our results have important implications for air quality management in the Beijing subway system. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Impacts of a large boreal wildfire on ground level atmospheric concentrations of PAHs, VOCs and ozone

    NASA Astrophysics Data System (ADS)

    Wentworth, Gregory R.; Aklilu, Yayne-abeba; Landis, Matthew S.; Hsu, Yu-Mei

    2018-04-01

    During May 2016 a very large boreal wildfire burned throughout the Athabasca Oil Sands Region (AOSR) in central Canada, and in close proximity to an extensive air quality monitoring network. This study examines speciated 24-h integrated polycyclic aromatic hydrocarbon (PAH) and volatile organic compound (VOC) measurements collected every sixth day at four and seven sites, respectively, from May to August 2016. The sum of PAHs (ΣPAH) was on average 17 times higher in fire-influenced samples (852 ng m-3, n = 8), relative to non-fire influenced samples (50 ng m-3, n = 64). Diagnostic PAH ratios in fire-influenced samples were indicative of a biomass burning source, whereas ratios in June to August samples showed additional influence from petrogenic and fossil fuel combustion. The average increase in the sum of VOCs (ΣVOC) was minor by comparison: 63 ppbv for fire-influenced samples (n = 16) versus 46 ppbv for non-fire samples (n = 90). The samples collected on August 16th and 22nd had large ΣVOC concentrations at all sites (average of 123 ppbv) that were unrelated to wildfire emissions, and composed primarily of acetaldehyde and methanol suggesting a photochemically aged air mass. Normalized excess enhancement ratios (ERs) were calculated for 20 VOCs and 23 PAHs for three fire influenced samples, and the former were generally consistent with previous observations. To our knowledge, this is the first study to report ER measurements for a number of VOCs and PAHs in fresh North American boreal wildfire plumes. During May the aged wildfire plume intercepted the cities of Edmonton (∼380 km south) or Lethbridge (∼790 km south) on four separate occasions. No enhancement in ground-level ozone (O3) was observed in these aged plumes despite an assumed increase in O3 precursors. In the AOSR, the only daily-averaged VOCs which approached or exceeded the hourly Alberta Ambient Air Quality Objectives (AAAQOs) were benzene (during the fire) and acetaldehyde (on August 16th and 22nd). Implications for local and regional air quality as well as suggestions for supplemental air monitoring during future boreal fires, are also discussed.

  2. Characterization of the ambient air content of parent polycyclic aromatic hydrocarbons in the Fort McKay region (Canada).

    PubMed

    Wnorowski, Andrzej

    2017-05-01

    This study presents the characterization of the gas-particle partition and size distribution of seven parent polycyclic aromatic hydrocarbons (PAHs) in ambient air samples collected in the proximity of oil sands exploration and compares their time-integrated concentration levels with nineteen analogous oxidation products - quinones. Gas-phase (GP) and particle-phase (PM) ambient air aerosol samples that were collected separately in summer for either 24 h or 12 h (day and night) revealed a higher PAH partition in the GP than in the PM, with the distribution over tenfold higher for light over heavy PAHs. Diurnal/nocturnal samples demonstrated that night conditions lead to lower concentrations, linking some of the sources of these compounds with daytime activity emissions. PAHs were observed to transform more efficiently in the GP, and quinone levels increased in the PM with time. Correlation data indicated that parent PAHs originated from primary emission sources associated with oil sand activities and that quinone formation paralleled a reduction in PAH levels. The findings of this study shed new light on characterization of PAHs in the Athabasca oil sands region. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  3. Inhalation Exposure of Organophosphate Pesticides by Vegetable Growers in the Bang-Rieng Subdistrict in Thailand

    PubMed Central

    Jaipieam, Somsiri; Visuthismajarn, Parichart; Siriwong, Wattasit; Borjan, Marija; Robson, Mark G.

    2009-01-01

    This study investigated inhalation exposure to organophosphate pesticides (OPPs) and evaluated the associated health risks to vegetable growers living in the Bang-Rieng agricultural community. Air samples were collected by using personal sampling pumps with sorbent tubes placed in the vegetable growers' breathing zone. Samples were collected during both wet and dry seasons. Residues of organophosphate pesticides, that is, chlorpyrifos, dicrotofos, and profenofos, were analyzed from 33 vegetable growers and 17 reference subjects. Results showed that median concentrations of OPPs in air in farm areas were in the range of 0.022–0.056 mg/m3 and air in nonfarm areas in the range of <0.0016–<0.005 mg/m3. The concentration of the three pesticides in the vegetable growers was significantly higher than that of the references during both seasons. The results also indicate that the vegetable growers may be at risk for acute adverse effects via the inhalation of chlorpyrifos and dicrotofos during pesticide application, mixing, loading, and spraying. It is suggested that authorities and the community should implement appropriate strategies concerning risk reduction and risk management. PMID:20168980

  4. Design and Operation of a Borehole Straddle Packer for Ground-Water Sampling and Hydraulic Testing of Discrete Intervals at U.S. Air Force Plant 6, Marietta, Georgia

    USGS Publications Warehouse

    Holloway, Owen G.; Waddell, Jonathan P.

    2008-01-01

    A borehole straddle packer was developed and tested by the U.S. Geological Survey to characterize the vertical distribution of contaminants, head, and hydraulic properties in open-borehole wells as part of an ongoing investigation of ground-water contamination at U.S. Air Force Plant 6 (AFP6) in Marietta, Georgia. To better understand contaminant fate and transport in a crystalline bedrock setting and to support remedial activities at AFP6, numerous wells have been constructed that include long open-hole intervals in the crystalline bedrock. These wells can include several discontinuities that produce water, which may contain contaminants. Because of the complexity of ground-water flow and contaminant movement in the crystalline bedrock, it is important to characterize the hydraulic and water-quality characteristics of discrete intervals in these wells. The straddle packer facilitates ground-water sampling and hydraulic testing of discrete intervals, and delivery of fluids including tracer suites and remedial agents into these discontinuities. The straddle packer consists of two inflatable packers, a dual-pump system, a pressure-sensing system, and an aqueous injection system. Tests were conducted to assess the accuracy of the pressure-sensing systems, and water samples were collected for analysis of volatile organic compound (VOCs) concentrations. Pressure-transducer readings matched computed water-column height, with a coefficient of determination of greater than 0.99. The straddle packer incorporates both an air-driven piston pump and a variable-frequency, electronic, submersible pump. Only slight differences were observed between VOC concentrations in samples collected using the two different types of sampling pumps during two sampling events in July and August 2005. A test conducted to assess the effect of stagnation on VOC concentrations in water trapped in the system's pump-tubing reel showed that concentrations were not affected. A comparison was conducted to assess differences between three water-sampling methods - collecting samples from the well by pumping a packer-isolated zone using a submersible pump, by using a grab sampler, and by using a passive diffusion sampler. Concentrations of tetrachloroethylene, trichloroethylene and 1,2-dichloropropane were greatest for samples collected using the submersible pump in the packed-isolated interval, suggesting that the straddle packer yielded the least dilute sample.

  5. Extended duration orbiter medical project Microbial Air Sampler (STS-50/USML-1)

    NASA Technical Reports Server (NTRS)

    Pierson, Duane L.; Boettcher, Sheila W.

    1994-01-01

    The Microbial Air Sampler was used on mission days 1, 7, and 13 in the Spacelab during STS-50/USML-1. Microbial air samples were collected using two types of media strips containing agar (Rose Bengal for yeast and molds, TSA for bacteria). The bacterial level found on day 1 was lower than experienced on previous Spacelab missions. A high level of fungi was present on day 1, however subsequent samples on days 7 and 13 did not indicate fungal growth. Bacterial growth was also minimized in this microgravity environment as the mission progressed. No pathogenic microorganisms were isolated, and the health risk from airborne microbes was minimal throughout the mission.

  6. Quantitative filter forensics for indoor particle sampling.

    PubMed

    Haaland, D; Siegel, J A

    2017-03-01

    Filter forensics is a promising indoor air investigation technique involving the analysis of dust which has collected on filters in central forced-air heating, ventilation, and air conditioning (HVAC) or portable systems to determine the presence of indoor particle-bound contaminants. In this study, we summarize past filter forensics research to explore what it reveals about the sampling technique and the indoor environment. There are 60 investigations in the literature that have used this sampling technique for a variety of biotic and abiotic contaminants. Many studies identified differences between contaminant concentrations in different buildings using this technique. Based on this literature review, we identified a lack of quantification as a gap in the past literature. Accordingly, we propose an approach to quantitatively link contaminants extracted from HVAC filter dust to time-averaged integrated air concentrations. This quantitative filter forensics approach has great potential to measure indoor air concentrations of a wide variety of particle-bound contaminants. Future studies directly comparing quantitative filter forensics to alternative sampling techniques are required to fully assess this approach, but analysis of past research suggests the enormous possibility of this approach. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. RELATIONSIPS BETWEEN AQUATIC INVERTEBRATE ASSEMBLAGES AND REACH AND LANDSCAPE ATTRIBUTES ON WADEABLE, WILLAMETTE VALLEY STREAMS IN AGRICULTURAL WATERSHEDS

    EPA Science Inventory

    In summer 1997, we sampled reaches in 24 wadeable, Willamette Valley ecoregion streams draining agriculturally-infiuenced watersheds. Within these reaches, physical habitat, water chemistry, aquatic invertebrate and fish data and samples were collected. Low-level air photos were ...

  8. Source Testing for Particulate Matter.

    ERIC Educational Resources Information Center

    DeVorkin, Howard

    Developed for presentation at the 12th Conference on Methods in Air Pollution and Industrial Hygiene Studies, University of Southern California, April, 1971, this outline covers procedures for the testing of particulate matter. These are: (1) basic requirements, (2) information required, (3) collection of samples, (4) processing of samples, (5)…

  9. MAPPING DISSEMINATION OF CHEMICAL AFTER DISPERSIVE EVENTS USING AN AMBIENT-AIR, SURFACE SAMPLING TIME-OF-FLIGHT MASS SPECTROMETER

    EPA Science Inventory

    Chemicals are dispersed by numerous accidental, deliberate, or weather-related events. Often, rapid analyses are desired to identify dispersed chemicals and to delineate areas of contamination. Hundreds of wipe samples might be collected from outdoor surfaces or building interi...

  10. Early Detection of Foot-And-Mouth Disease Virus from Infected Cattle Using A Dry Filter Air Sampling System.

    PubMed

    Pacheco, J M; Brito, B; Hartwig, E; Smoliga, G R; Perez, A; Arzt, J; Rodriguez, L L

    2017-04-01

    Foot-and-mouth disease (FMD) is a highly contagious livestock disease of high economic impact. Early detection of FMD virus (FMDV) is fundamental for rapid outbreak control. Air sampling collection has been demonstrated as a useful technique for detection of FMDV RNA in infected animals, related to the aerogenous nature of the virus. In the current study, air from rooms housing individual (n = 17) or two groups (n = 4) of cattle experimentally infected with FDMV A24 Cruzeiro of different virulence levels was sampled to assess the feasibility of applying air sampling as a non-invasive, screening tool to identify sources of FMDV infection. Detection of FMDV RNA in air was compared with first detection of clinical signs and FMDV RNA levels in serum and oral fluid. FMDV RNA was detected in room air samples 1-3 days prior (seven animals) or on the same day (four animals) as the appearance of clinical signs in 11 of 12 individually housed cattle. Only in one case clinical signs preceded detection in air samples by one day. Overall, viral RNA in oral fluid or serum preceded detection in air samples by 1-2 days. Six individually housed animals inoculated with attenuated strains did not show clinical signs, but virus was detected in air in one of these cases 3 days prior to first detection in oral fluid. In groups of four cattle housed together, air detection always preceded appearance of clinical signs by 1-2 days and coincided more often with viral shedding in oral fluid than virus in blood. These data confirm that air sampling is an effective non-invasive screening method for detecting FMDV infection in confined to enclosed spaces (e.g. auction barns, milking parlours). This technology could be a useful tool as part of a surveillance strategy during FMD prevention, control or eradication efforts. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  11. A new analysis system for whole air sampling: description and results from 2013 SENEX

    NASA Astrophysics Data System (ADS)

    Lerner, B. M.; Gilman, J.; Dumas, M.; Hughes, D.; Jaksich, A.; Hatch, C. D.; Graus, M.; Warneke, C.; Apel, E. C.; Hornbrook, R. S.; Holloway, J. S.; De Gouw, J. A.

    2014-12-01

    Accurate measurement of volatile organic compounds (VOCs) in the troposphere is critical for the understanding of emissions and physical and chemical processes that can impact both air quality and climate. Airborne VOC measurements have proven especially challenging due to the requirement of both high sensitivity (pptv) and short sample collection times (≤15 s) to maximize spatial resolution and sampling frequency for targeted plume analysis. The use of stainless steel canisters to collect whole air samples (WAS) for post-flight analysis has been pioneered by the groups of D. Blake and E. Atlas [Blake et al., 1992; Atlas et al., 1993]. For the 2013 Southeast Nexus Study (SENEX), the NOAA ESRL CSD laboratory undertook WAS measurements for the first time. This required the construction of three new, highly-automated, and field-portable instruments designed to sample, analyze, and clean the canisters for re-use. Analysis was performed with a new custom-built gas chromatograph-mass spectrometer system. The instrument pre-concentrates analyte cryostatically into two parallel traps by means of a Stirling engine, a novel technique which obviates the need for liquid nitrogen to reach trapping temperatures of -175C. Here we present an evaluation of the retrieval of target VOC species from WAS canisters. We discuss the effects of humidity and sample age on the analyte, particularly upon C8+ alkane and aromatic species and biogenic species. Finally, we present results from several research flights during SENEX that targeted emissions from oil/natural gas production.

  12. Design and implementation of an air monitoring program in support of a brownfields redevelopment program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maisel, B.E.; Hunt, G.T.; Devaney, R.J. Jr.

    EPA`s Brownfields Economic Redevelopment Initiative has sparked renewal of industrial and commercial parcels otherwise idled or under-utilized because of real or perceived environmental contamination. In certain cases, restoring such parcels to productive economic use requires a redevelopment effort protective of human health and welfare through minimizing offsite migration of environmental contaminants during cleanup, demolition and remediation activities. To support these objectives, an air monitoring program is often required as an integral element of a comprehensive brownfields redevelopment effort. This paper presents a strategic framework for design and execution of an ambient air monitoring program in support of a brownfields remediationmore » effort ongoing in Lawrence, MA. Based on site characterization, the program included sample collection and laboratory analysis of ambient air samples for polychlorinated biphenyls (PCBs), polychlorinated dibenzodioxins and polychlorinated dibenzofurans (PCDDs/PCDFs), total suspended particulate (TSP), inhalable particulate (PM10), and lead. The program included four monitoring phases, identified as background, wintertime, demolition/remediation and post-demolition. Air sampling occurred over a 16 month period during 1996--97, during which time nine sampling locations were utilized to produce approximately 1,500 ambient air samples. Following strict data review and validation procedures, ambient air data interpretation focused on the following: evaluation of upwind/downwind sample pairs, comparison of ambient levels to existing regulatory standards, relation of ambient levels to data reported in the open literature, and, determination of normal seasonal variations in existing background burden, comparison of ambient levels measured during site activity to background levels.« less

  13. Air monitoring of volatile organic compounds at relevant receptors during hydraulic fracturing operations in Washington County, Pennsylvania.

    PubMed

    Maskrey, Joshua R; Insley, Allison L; Hynds, Erin S; Panko, Julie M

    2016-07-01

    A 3-month air monitoring study was conducted in Washington County, Pennsylvania, at the request of local community members regarding the potential risks resulting from air emissions of pollutants related to hydraulic fracturing operations. Continuous air monitoring for total volatile organic compounds was performed at two sampling sites, including a school and a residence, located within 900 m of a hydraulic fracturing well pad that had been drilled prior to the study. Intermittent 24-hour air samples for 62 individual volatile organic compounds were also collected. The ambient air at both sites was monitored during four distinct periods of unconventional natural gas extraction activity: an inactive period prior to fracturing operations, during fracturing operations, during flaring operations, and during another inactive period after operations. The results of the continuous monitoring during fracturing and flaring sampling periods for total volatile organic compounds were similar to the results obtained during inactive periods. Total volatile organic compound 24-hour average concentrations ranged between 0.16 and 80 ppb during all sampling periods. Several individual volatile compounds were detected in the 24-hour samples, but they were consistent with background atmospheric levels measured previously at nearby sampling sites and in other areas in Washington County. Furthermore, a basic yet conservative screening level evaluation demonstrated that the detected volatile organic compounds were well below health-protective levels. The primary finding of this study was that the operation of a hydraulic fracturing well pad in Washington County did not substantially affect local air concentrations of total and individual volatile organic compounds.

  14. Guide for SDEC Set up

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bibby, R; Guthrie, E

    2009-01-30

    The instrument has four collection vials that must be filled with ethylene glycol before operation. Each of the four vials should be labeled 1 through 4 and the empty weights recorded. Fill each vial with 80 mL of ethylene glycol and record the weight again. In order for the instrument to operate properly, the collection vials should always have less than 160 mL of total liquid in them. After completing a sample run, remove the collection vials, use a transfer pipette to remove any liquid that might still be on the air paddler, wipe off any condensation from the exteriormore » of the collection vial and record weight. From the instrument, record the ending volume and the time of operation. The solution mixed in the scintillation vial will be 2 ml of a 95% to 50% ethylene glycol to water mixture. To determine the efficiency of counting at all of these concentrations, a series of vials should be set up that consist of 18 ml of Ultima Gold LLT cocktail mixed with standard, regular deionized water and ethylene glycol. The efficiency curve should be counted in the 'Low Level' count mode with the Luminescence Correction ON and the Color Quench Correction ON. Once the tSIE values are determined, chart the cpm against the tSIE numbers and find the best fit for the data. The resulting equation is to be used to converting tSIE values from the collection vials to efficiency. To determine the background cpm value of the ethylene glycol, count a 2 ml sample of ethylene glycol with 18 ml of Ultima Gold for 100 minutes. To determine the total activity of the sample, take two 2 ml aliquots of sample from the first vial and place in separate scintillation vials. Record the weight of each aliquot. Determine the percentage of total sample each aliquot represents by dividing the aliquot weight by the total solution weight from the vial. Also, determine the percentage of ethylene glycol in the sample by dividing the initial solution weight by the final solution weight and multiplying by 100. Add 18 ml of Ultima Gold to each vial and proceed to count for 100 minutes in a 'Low Level' count mode. Before performing a calculation on the dpm value of each aliquot, a subtraction should be made for the background count rate of the ethylene glycol. Based on the background cpm, multiply the background cpm value by the percentage of ethylene glycol in the collection vial. Once the background value is subtracted, calculate the dpm value of the sample based on the tSIE conversion to efficiency. This will produce a dpm value. To convert this to a total activity of the sample, divide the aliquot dpm value by the decimal percentage of total sample the aliquot represents. This gives the total activity of the sample solution. Take the average of both aliquots as a final result. To convert the total activity from the solution in vial one to activity in air, an empirical formula is used to convert activity/gram from vial one to total activity introduced into the system. After calculation the final result for the vial, divide the total by the mass of the sample in vial one. This gives dpm/g (labeled C{sub m}). To convert this to total dpm measured, C = (128.59 * Cm + 10.837)/V Where: C = Tritium concentration in air (dpm/m{sup 3}) C{sub m} = measured tritium concentration from vial 1 (dpm/g) V = Volume of air sampled through instrument (m{sup 3}). C is the final value of tritium concentration in air.« less

  15. Portable apparatus for the measurement of environmental radon and thoron

    DOEpatents

    Negro, Vincent C.

    2001-01-01

    The radometer is a portable instrument for the measurement of the concentration of atmospheric radon/thoron in a test area. A constant velocity pump pulls the air from the outside at a constant flow rate. If the air is too moist, some or all of the sample is passed through a desiccant filter prior to encountering an electrostatic filter. The electrostatic filter prevents any charged particles from entering the sampling chamber. Once the sample has entered the chamber, the progeny of the decay of radon/thoron are collected on a detector and measured. The measured data is compiled by a computer and displayed.

  16. Development of size-selective sampling of Bacillus anthracis surrogate spores from simulated building air intake mixtures for analysis via laser-induced breakdown spectroscopy.

    PubMed

    Gibb-Snyder, Emily; Gullett, Brian; Ryan, Shawn; Oudejans, Lukas; Touati, Abderrahmane

    2006-08-01

    Size-selective sampling of Bacillus anthracis surrogate spores from realistic, common aerosol mixtures was developed for analysis by laser-induced breakdown spectroscopy (LIBS). A two-stage impactor was found to be the preferential sampling technique for LIBS analysis because it was able to concentrate the spores in the mixtures while decreasing the collection of potentially interfering aerosols. Three common spore/aerosol scenarios were evaluated, diesel truck exhaust (to simulate a truck running outside of a building air intake), urban outdoor aerosol (to simulate common building air), and finally a protein aerosol (to simulate either an agent mixture (ricin/anthrax) or a contaminated anthrax sample). Two statistical methods, linear correlation and principal component analysis, were assessed for differentiation of surrogate spore spectra from other common aerosols. Criteria for determining percentages of false positives and false negatives via correlation analysis were evaluated. A single laser shot analysis of approximately 4 percent of the spores in a mixture of 0.75 m(3) urban outdoor air doped with approximately 1.1 x 10(5) spores resulted in a 0.04 proportion of false negatives. For that same sample volume of urban air without spores, the proportion of false positives was 0.08.

  17. Effect of air pollution on the total bacteria and pathogenic bacteria in different sizes of particulate matter.

    PubMed

    Liu, Huan; Zhang, Xu; Zhang, Hao; Yao, Xiangwu; Zhou, Meng; Wang, Jiaqi; He, Zhanfei; Zhang, Huihui; Lou, Liping; Mao, Weihua; Zheng, Ping; Hu, Baolan

    2018-02-01

    In recent years, air pollution events have occurred frequently in China during the winter. Most studies have focused on the physical and chemical composition of polluted air. Some studies have examined the bacterial bioaerosols both indoors and outdoors. But few studies have focused on the relationship between air pollution and bacteria, especially pathogenic bacteria. Airborne PM samples with different diameters and different air quality index values were collected in Hangzhou, China from December 2014 to January 2015. High-throughput sequencing of 16S rRNA was used to categorize the airborne bacteria. Based on the NCBI database, the "Human Pathogen Database" was established, which is related to human health. Among all the PM samples, the diversity and concentration of total bacteria were lowest in the moderately or heavily polluted air. However, in the PM2.5 and PM10 samples, the relative abundances of pathogenic bacteria were highest in the heavily and moderately polluted air respectively. Considering the PM samples with different particle sizes, the diversities of total bacteria and the proportion of pathogenic bacteria in the PM10 samples were different from those in the PM2.5 and TSP samples. The composition of PM samples with different sizes range may be responsible for the variances. The relative humidity, carbon monoxide and ozone concentrations were the main factors, which affected the diversity of total bacteria and the proportion of pathogenic bacteria. Among the different environmental samples, the compositions of the total bacteria were very similar in all the airborne PM samples, but different from those in the water, surface soil, and ground dust samples. Which may be attributed to that the long-distance transport of the airflow may influence the composition of the airborne bacteria. This study of the pathogenic bacteria in airborne PM samples can provide a reference for environmental and public health researchers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Innovations in air sampling to detect plant pathogens

    PubMed Central

    West, JS; Kimber, RBE

    2015-01-01

    Many innovations in the development and use of air sampling devices have occurred in plant pathology since the first description of the Hirst spore trap. These include improvements in capture efficiency at relatively high air-volume collection rates, methods to enhance the ease of sample processing with downstream diagnostic methods and even full automation of sampling, diagnosis and wireless reporting of results. Other innovations have been to mount air samplers on mobile platforms such as UAVs and ground vehicles to allow sampling at different altitudes and locations in a short space of time to identify potential sources and population structure. Geographical Information Systems and the application to a network of samplers can allow a greater prediction of airborne inoculum and dispersal dynamics. This field of technology is now developing quickly as novel diagnostic methods allow increasingly rapid and accurate quantifications of airborne species and genetic traits. Sampling and interpretation of results, particularly action-thresholds, is improved by understanding components of air dispersal and dilution processes and can add greater precision in the application of crop protection products as part of integrated pest and disease management decisions. The applications of air samplers are likely to increase, with much greater adoption by growers or industry support workers to aid in crop protection decisions. The same devices are likely to improve information available for detection of allergens causing hay fever and asthma or provide valuable metadata for regional plant disease dynamics. PMID:25745191

  19. Detection of Multi-walled Carbon Nanotubes and Carbon Nanodiscs on Workplace Surfaces at a Small-Scale Producer.

    PubMed

    Hedmer, Maria; Ludvigsson, Linus; Isaxon, Christina; Nilsson, Patrik T; Skaug, Vidar; Bohgard, Mats; Pagels, Joakim H; Messing, Maria E; Tinnerberg, Håkan

    2015-08-01

    The industrial use of novel-manufactured nanomaterials such as carbon nanotubes and carbon nanodiscs is increasing globally. Occupational exposure can occur during production, downstream use, and disposal. The health effects of many nanomaterials are not yet fully characterized and to handle nano-objects, their aggregates and agglomerates >100nm (NOAA), a high degree of control measures and personal protective equipment are required. The emission of airborne NOAA during production and handling can contaminate workplace surfaces with dust, which can be resuspended resulting in secondary inhalation exposures and dermal exposures. This study surveys the presence of carbon-based nanomaterials, such as multi-walled carbon nanotubes (MWCNTs) and carbon nanodiscs, as surface contamination at a small-scale producer using a novel tape sampling method. Eighteen different surfaces at a small-scale producer were sampled with an adhesive tape sampling method. The surfaces selected were associated with the production and handling of MWCNT powder in the near-field zone. Surfaces in the far-field zone were also sampled. In addition, tape stripping of the skin was performed on one worker. The tape samples were analysed with scanning electron microscopy to detect the carbon-based NOAA. Air sampling with a personal impactor was also performed on a worker who was producing MWCNTs the same day as the tape samples were collected. MWCNTs were detected in 50% of the collected tape samples and carbon nanodiscs in 17%. MWCNTs and carbon nanodiscs were identified in all parts of the workplace, thus, increasing the risk for secondary inhalation and dermal exposure of the workers. Both airborne MWCNTs and carbon nanodiscs were detected in the personal impactor samples. The tape-strip samples from the worker showed no presence of carbon-containing nanoparticles. Tape sampling is a functional method for detecting surface contamination of carbon-based NOAA and for exposure control during production at potentially any workplace that produces or handles such manufactured nanomaterials. With the tape method, it is possible to monitor if a potential for secondary inhalation exposure or dermal exposure exists through resuspension of dust deposited on workplace surfaces. By means of air sampling, we could confirm that carbon nanodiscs were resuspended into the air at the workplace even though they were not handled during that particular work shift. MWCNTs were detected in the air samples, but can have been derived from either resuspension or from the work tasks with MWCNTs that were performed during the air sampling. Tape sampling is a complementary method to air sampling and together these two methods provide a better view of the hygienic situation in workplaces where NOAA can be emitted into work environments. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  20. The molecular characteristics of avian influenza viruses (H9N2) derived from air samples in live poultry markets.

    PubMed

    Wu, Yanheng; Lin, Jinsi; Yang, Shuhuan; Xie, Ying; Wang, Man; Chen, Xueqin; Zhu, Yayang; Luo, Le; Shi, Wuyang

    2018-06-01

    To study the molecular characteristics of H9N2-subtype avian influenza viruses (AIVs) isolated from air samples collected in live poultry markets (LPMs) and explore their sequence identities with AIVs that caused human infection. Weekly surveillance of H9N2-subtype AIVs in the air of LPMs was conducted from 2015 to 2016. H9-positive samples were isolated from chicken embryos. Whole genome sequences of the isolated AIVs were obtained through high-throughput sequencing. Phylogenetic analysis and key loci variations of the sequences were further analyzed. A total of 327 aerosol samples were collected from LPMs. Nine samples were positive for H9-subtype AIVs based on quantitative real-time reverse transcription polymerase chain reaction (qRRT-PCR). According to the whole genome sequence analysis and phylogenetic analysis, except for the A/Environment/Zhongshan/ZS201505/2015 (ZS201505) strain, 8 gene segments of 8 aerosol H9N2 isolates and 2 H9N2 human isolates in 2015 were located in the same clade. Among key loci variations, except for the ZS201505 strain, H9N2-subtype AIVs had no mutations in eight receptor binding sites of hemagglutinin (HA), and stalks of neuraminidase (NA) proteins exhibited a deletion site of three bases. The PA gene of ZS201503 and ZS201602 exhibited an L336M mutation. The N30D and T215A mutations in the M1 gene and amino acid residues L89V in PB2, P42S in NS1 and S31N in M2 were retained in these 9 strains of H9N2 isolates, which could enhance the virus's virulence. Live H9N2 AIVs survived in the aerosol of LPMs in Zhongshan City. The aerosol viruses had a close evolutionary relationship with human epidemic strains, indicating that there might be a risk of AIV transmission from polluted aerosols in LPMs to humans. Mutations in H9N2-subtype AIVs isolated from air samples collected from LPMs suggested their pathogenicity was enhanced to infect humans. Copyright © 2018. Published by Elsevier B.V.

  1. Storage conditions for stability of offline measurement of fractional exhaled nitric oxide after collection for epidemiologic research

    PubMed Central

    2012-01-01

    Background The measurement of fractional concentration of nitric oxide in exhaled air (FeNO) is valuable for the assessment of airway inflammation. Offline measurement of FeNO has been used in some epidemiologic studies. However, the time course of the changes in FeNO after collection has not been fully clarified. In this study, the effects of storage conditions on the stability of FeNO measurement in exhaled air after collection for epidemiologic research were examined. Methods Exhaled air samples were collected from 48 healthy adults (mean age 43.4 ± 12.1 years) in Mylar bags. FeNO levels in the bags were measured immediately after collection. The bags were then stored at 4°C or room temperature to measure FeNO levels repeatedly for up to 168 hours. Results In the bags stored at room temperature after collection, FeNO levels were stable for 9 hours, but increased starting at 24 hours. FeNO levels remained stable for a long time at 4°C, and they were 99.7% ± 7.7% and 101.3% ± 15.0% relative to the baseline values at 24 and 96 hours, respectively. When the samples were stored at 4°C, FeNO levels gradually decreased with time among the subjects with FeNO ≥ 51 ppb immediately after collection, although there were almost no changes among the other subjects. FeNO levels among current smokers increased even at 4°C, although the values among ex-smokers decreased gradually, and those among nonsmokers remained stable. The rate of increase was significantly higher among current smokers than among nonsmokers and ex-smokers from 9 hours after collection onwards. Conclusions Storage at 4°C could prolong the stability of FeNO levels after collection. This result suggests that valid measurements can be performed within several days if the samples are stored at 4°C. However, the time course of the changes in FeNO levels differed in relation to initial FeNO values and cigarette smoking. PMID:23116255

  2. Urine chromium as an estimator of air exposure to stainless steel welding fumes.

    PubMed

    Sjögren, B; Hedström, L; Ulfvarson, U

    1983-01-01

    Welding stainless steel with covered electrodes, also called manual metal arc welding, generates hexavalent airborne chromium. Chromium concentrations in air and post-shift urine samples, collected the same arbitrarily chosen working day, showed a linear relationship. Since post-shift urine samples reflect chromium concentrations of both current and previous stainless steel welding fume exposure, individual urine measurements are suggested as approximate although not exact estimators of current exposure. This study evaluates the practical importance of such measurements by means of confidence limits and tests of validity.

  3. Space Shuttle solid rocket motor exposure monitoring

    NASA Technical Reports Server (NTRS)

    Brown, S. W.

    1993-01-01

    During the processing of the Space Shuttle Solid Rocket Booster (SRB), segments at the Kennedy Space Center, an odor was detected around the solid propellant. An Industrial Hygiene survey was conducted to determine the chemical identity of the SRB offgassing constituents. Air samples were collected inside a forward SRB segment and analyzed to determine chemical composition. Specific chemical analysis for suspected offgassing constituents of the propellant indicated ammonia to be present. A gas chromatograph mass spectroscopy (GC/MS) analysis of the air samples detected numerous high molecular weight hydrocarbons.

  4. New insight into the distribution pattern, levels, and risk diagnosis of FRs in indoor and outdoor air at low- and high-altitude zones of Pakistan: Implications for sources and exposure.

    PubMed

    Khan, Muhammad Usman; Besis, Athanasios; Li, Jun; Zhang, Gan; Malik, Riffat Naseem

    2017-10-01

    Data regarding flame retardants (FRs) in indoor and outdoor air and their exposure to population are scarce and especially unknown in the case of Pakistan. The current study was designed to probe FR concentrations and distribution pattern in indoor and outdoor air at different altitudinal zones (DAZs) of Pakistan with special emphasis on their risk to the exposed population. In this study, passive air samplers for the purpose of FR deposition were deployed in indoor and outdoor air at the industrial, rural, and background/colder zones/sites. All the indoor and outdoor air samples collected from DAZs were analyzed for the target FRs (9.30-472.30 pg/m 3 ), showing a decreasing trend as follows: ∑NBFRs > ∑PBDEs > ∑DP. However, significant correlations among FRs in the indoor and outdoor air at DAZs signified a similar source of FR origin that is used in different consumer goods. Furthermore, air mass trajectories revealed that movement of air over industrial area sources influenced concentrations of FRs at rural sites. The FR concentrations, estimated daily intake (EDI) and the hazard quotient (HQ), were recorded to be higher in toddlers than those in adults. In addition, indoor air samples showed higher FR levels, EDI and HQ, than outdoor air samples. An elevated FR concentrations and their prevalent exposure risks were recorded in the industrial zones followed by rural and background zones. The HQ for BDE-47 and BDE-99 in the indoor and outdoor air samples at different industrial and rural sites were recorded to be >1 in toddlers and adults, this further warrants a health risk in the population. However, FR investigation in indoor and outdoor air samples will provide a baseline data in Pakistan to take further steps by the government and agencies for its implementations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Investigation of Air Quality Problems in an Indoor Swimming Pool: A Case Study.

    PubMed

    Lévesque, Benoit; Vézina, Lorraine; Gauvin, Denis; Leroux, Patrice

    2015-10-01

    Trichloramine (NCl3) is the contaminant suspected the most to cause irritative respiratory symptoms among swimmers and swimming pool workers. Following complaints by employees working in an indoor swimming pool, this study set out to identify the determinants of NCl3 air concentrations in that particular swimming pool. To document NCl3 air levels, air samples (n = 26) were collected once or twice a day for 3 h, at least 3 days per week, between October and December 2011. Water samples were taken three times during air sampling to verify free chlorine, chloramines, alkalinity, conductivity, pH, water temperature, and turbidity. Water changes were also recorded, along with the number of bathers. Ventilation (outdoor air flow) was modified to verify the influence of this important variable. Data were evaluated by analysis of variance. Mean NCl3 air concentration was 0.38 mg m(-3). The best model explaining variations of NCl3 air levels (r2 = 0.83) included sampling period (P = 0.002, NCl3 was higher in the evening versus the morning), water changes (P = 0.02, NCl3 was lower with water changes between 60 and 90 min day(-1) versus <60 min day(-1)), and ventilation (P = 0.0002, NCl3 was lower with ≥2 air changes per hour (ACH) versus <1 ACH). Although based on only 26 air samples, our results indicate that ventilation is an important determinant of NCl3 air concentration in swimming pool air. There is limited information available on the air quality of indoor swimming pools and the relationship with ventilation. Efforts are needed to document the situation and to develop state-of-the-art facilities for ventilation of indoor swimming pools. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  6. Comparison of mold concentrations quantified by MSQPCR in indoor and outdoor air sampled simultaneously

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meklin, Teija; Reponen, Tina; McKinstry, Craig A.

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of 36 mold species in dust and in indoor and in outdoor air samples that were taken simultaneously in 17 homes in Cincinnati with no-known water damage. The total spore concentrations in the indoor (I) and outdoor (O) air samples were statistically significantly different and the concentrations in the three sample types of many of the individual species were significantly different (p < 0.05 based on the Wilcoxon Signed Rank Test). The I/O ratios of the averages or geometric means of the individual species were generally less than 1;more » but these I/O ratios were quite variable ranging from 0.03 for A. sydowii to 1.2 for Acremonium strictum. There were no significant correlations for the 36 specific mold concentrations between the dust samples and the indoor or outdoor air samples (based on the Spearman’s Rho test). The indoor and outdoor air concentrations of 32 of the species were not correlated. Only Aspergillus penicillioides, C. cladosporioides types 1 and 2 and C. herbarum had sufficient data to estimate a correlation at rho > 0.5 with signicance (p < 0.05) In six of these homes, a previous dust sample had been collected and analyzed 2 years earlier. The ERMI© values for the dust samples taken in the same home two years apart were not significantly different (p=0.22) based on Wilcoxon Signed Rank Test.« less

  7. Neuraminidase as an enzymatic marker for detecting airborne Influenza virus and other viruses.

    PubMed

    Turgeon, Nathalie; Toulouse, Marie-Josée; Ho, Jim; Li, Dongqing; Duchaine, Caroline

    2017-02-01

    Little information is available regarding the effectiveness of air samplers to collect viruses and regarding the effects of sampling processes on viral integrity. The neuraminidase enzyme is present on the surface of viruses that are of agricultural and medical importance. It has been demonstrated that viruses carrying this enzyme can be detected using commercial substrates without having to process the sample by methods such as RNA extraction. This project aims at evaluating the effects of 3 aerosol-sampling devices on the neuraminidase enzyme activity of airborne viruses. The purified neuraminidase enzymes from Clostridium perfringens, a strain of Influenza A (H1N1) virus, the FluMist influenza vaccine, and the Newcastle disease virus were used as models. The neuraminidase models were aerosolized in aerosol chambers and sampled with 3 different air samplers (SKC BioSampler, 3-piece cassettes with polycarbonate filters, and Coriolis μ) to assess the effect on neuraminidase enzyme activity. Our results demonstrated that Influenza virus and Newcastle disease virus neuraminidase enzymes are resistant to aerosolization and sampling with all air samplers tested. Moreover, we demonstrated that the enzymatic neuraminidase assay is as sensitive as RT-qPCR for detecting low concentrations of Influenza virus and Newcastle disease virus. Therefore, given the sensitivity of the assay and its compatibility with air sampling methods, viruses carrying the neuraminidase enzyme can be rapidly detected from air samples using neuraminidase activity assay without having to preprocess the samples.

  8. THE NEW YORK CITY URBAN DISPERSION PROGRAM MARCH 2005 FIELD STUDY: TRACER METHODS AND RESULTS.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    WATSON, T.B.; HEISER, J.; KALB, P.

    The Urban Dispersion Program March 2005 Field Study tracer releases, sampling, and analytical methods are described in detail. There were two days where tracer releases and sampling were conducted. A total of 16.0 g of six tracers were released during the first test day or Intensive Observation Period (IOP) 1 and 15.7 g during IOP 2. Three types of sampling instruments were used in this study. Sequential air samplers, or SAS, collected six-minute samples, while Brookhaven atmospheric tracer samplers (BATS) and personal air samplers (PAS) collected thirty-minute samples. There were a total of 1300 samples resulting from the two IOPs.more » Confidence limits in the sampling and analysis method were 20% as determined from 100 duplicate samples. The sample recovery rate was 84%. The integrally averaged 6-minute samples were compared to the 30-minute samples. The agreement was found to be good in most cases. The validity of using a background tracer to calculate sample volumes was examined and also found to have a confidence level of 20%. Methods for improving sampling and analysis are discussed. The data described in this report are available as Excel files. An additional Excel file of quality assured tracer data for use in model validation efforts is also available. The file consists of extensively quality assured BATS tracer data with background concentrations subtracted.« less

  9. Passive Sampling for Indoor and Outdoor Exposures to Chlorpyrifos, Azinphos-Methyl, and Oxygen Analogs in a Rural Agricultural Community

    PubMed Central

    Gibbs, Jenna L.; Yost, Michael G.; Negrete, Maria; Fenske, Richard A.

    2016-01-01

    Background: Recent studies have highlighted the increased potency of oxygen analogs of organophosphorus pesticides. These pesticides and oxygen analogs have previously been identified in the atmosphere following spray applications in the states of California and Washington. Objectives: We used two passive sampling methods to measure levels of the ollowing organophosphorus pesticides: chlorpyrifos, azinphos-methyl, and their oxygen analogs at 14 farmworker and 9 non-farmworker households in an agricultural region of central Washington State in 2011. Methods: The passive methods included polyurethane foam passive air samplers deployed outdoors and indoors and polypropylene deposition plates deployed indoors. We collected cumulative monthly samples during the pesticide application seasons and during the winter season as a control. Results: Monthly outdoor air concentrations ranged from 9.2 to 199 ng/m3 for chlorpyrifos, 0.03 to 20 ng/m3 for chlorpyrifos-oxon, < LOD (limit of detection) to 7.3 ng/m3 for azinphos-methyl, and < LOD to 0.8 ng/m3 for azinphos-methyl-oxon. Samples from proximal households (≤ 250 m) had significantly higher outdoor air concentrations of chlorpyrifos, chlorpyrifos-oxon, and azinphos-methyl than did samples from nonproximal households (p ≤ 0.02). Overall, indoor air concentrations were lower than outdoors. For example, all outdoor air samples for chlorpyrifos and 97% of samples for azinphos-methyl were > LOD. Indoors, only 78% of air samples for chlorpyrifos and 35% of samples for azinphos-methyl were > LOD. Samples from farmworker households had higher indoor air concentrations of both pesticides than did samples from non-farmworker households. Mean indoor and outdoor air concentration ratios for chlorpyrifos and azinphos-methyl were 0.17 and 0.44, respectively. Conclusions: We identified higher levels in air and on surfaces at both proximal and farmworker households. Our findings further confirm the presence of pesticides and their oxygen analogs in air and highlight their potential for infiltration of indoor living environments. Citation: Gibbs JL, Yost MG, Negrete M, Fenske RA. 2017. Passive sampling for indoor and outdoor exposures to chlorpyrifos, azinphos-methyl, and oxygen analogs in a rural agricultural community. Environ Health Perspect 125:333–341; http://dx.doi.org/10.1289/EHP425 PMID:27517732

  10. DISTRIBUTION OF 2,4-D IN AIR AND ON SURFACES INSIDE RESIDENCES FOLLOWING LAWN APPLICATIONS: COMPARING EXPOSURE ESTIMATES FOR YOUNG CHILDREN FROM VARIOUS MEDIA

    EPA Science Inventory

    Indoor air, surface wipes (floors, table tops and window sills) and floor dust samples were collected at multiple locations within 11 occupied and 2 unoccupied homes both prior to and following lawn application of the herbicide 2,4-D. Residue measurements were made over period...

  11. Toxicological Assessment of ISS Air Quality: SpaceX-2 First Ingress

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie

    2013-01-01

    One mini-grab sample container (M-GSC) was collected by crew members onboard ISS during first ingress into SpaceX-2 on March 3, 2013, three days after late cargo loading and a pre-launch clean air purge. Recoveries of the three surrogate standards from the m-GSC were: 13C-acetone, 97%; fluorobenzene, 95%; and chlorobenzene, 68%.

  12. 40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...

  13. 40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...

  14. 40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...

  15. 40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...

  16. 40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...

  17. Assessing Performance of Spore Samplers in Monitoring Aeromycobiota and Fungal Plant Pathogen Diversity in Canada.

    PubMed

    Chen, Wen; Hambleton, Sarah; Seifert, Keith A; Carisse, Odile; Diarra, Moussa S; Peters, Rick D; Lowe, Christine; Chapados, Julie T; Lévesque, C André

    2018-05-01

    Spore samplers are widely used in pathogen surveillance but not so much for monitoring the composition of aeromycobiota. In Canada, a nationwide spore-sampling network (AeroNet) was established as a pilot project to assess fungal community composition in air and rain samples collected using three different spore samplers in the summers of 2010 and 2011. Metabarcodes of the internal transcribed spacer (ITS) were exhaustively characterized for three of the network sites, in British Columbia (BC), Québec (QC), and Prince Edward Island (PEI), to compare performance of the samplers. Sampler type accounted for ca. 20% of the total explainable variance in aeromycobiota compositional heterogeneity, with air samplers recovering more Ascomycota and rain samplers recovering more Basidiomycota. Spore samplers showed different abilities to collect 27 fungal genera that are plant pathogens. For instance, Cladosporium spp., Drechslera spp., and Entyloma spp. were collected mainly by air samplers, while Fusarium spp., Microdochium spp., and Ustilago spp. were recovered more frequently with rain samplers. The diversity and abundance of some fungi were significantly affected by sampling location and time (e.g., Alternaria and Bipolaris ) and weather conditions (e.g., Mycocentrospora and Leptosphaeria ), and depended on using ITS1 or ITS2 as the barcoding region (e.g., Epicoccum and Botrytis ). The observation that Canada's aeromycobiota diversity correlates with cooler, wetter conditions and northward wind requires support from more long-term data sets. Our vision of the AeroNet network, combined with high-throughput sequencing (HTS) and well-designed sampling strategies, may contribute significantly to a national biovigilance network for protecting plants of agricultural and economic importance in Canada. IMPORTANCE The current study compared the performance of spore samplers for collecting broad-spectrum air- and rain-borne fungal pathogens using a metabarcoding approach. The results provided a thorough characterization of the aeromycobiota in the coastal regions of Canada in relation to the influence of climatic factors. This study lays the methodological basis to eventually develop knowledge-based guidance on pest surveillance by assisting in the selection of appropriate spore samplers. © Crown copyright 2018.

  18. n-Aldehydes (C6-C10) in snow samples collected at the high alpine research station Jungfraujoch during CLACE 5

    NASA Astrophysics Data System (ADS)

    Sieg, K.; Starokozhev, E.; Fries, E.; Sala, S.; Püttmann, W.

    2009-03-01

    Samples of freshly fallen snow were collected at the high alpine research station Jungfraujoch, Switzerland, during the Cloud and Aerosol Characterization Experiments (CLACE) 5 in February and March 2006. Sampling was carried out on the Sphinx platform. Headspace-solid-phase-dynamic extraction (HS-SPDE) combined with gas chromatography/mass spectrometry (GC/MS) was used to quantify C6-C10 n-aldehydes in the snow samples. The most abundant n-aldehyde was n-hexanal (median concentration 1.324 μg L-1) followed by n-nonanal, n-decanal, n-octanal and n-heptanal (median concentrations 1.239, 0.863, 0.460, and 0.304 μg L-1, respectively). A wide range of concentrations was found among individual snow samples, even for samples taken at the same time. Higher median concentrations of all n-aldehydes were observed when air masses reached Jungfraujoch from the north-northwest in comparison to air masses arriving from the southeast-southwest. Results suggest that the n-aldehydes detected most likely are of direct and indirect biogenic origin, and that they entered the snow through the particle phase.

  19. Stenotrophomonas, Mycobacterium, and Streptomyces in home dust and air: associations with moldiness and other home/family characteristics.

    PubMed

    Kettleson, E; Kumar, S; Reponen, T; Vesper, S; Méheust, D; Grinshpun, S A; Adhikari, A

    2013-10-01

    Respiratory illnesses have been linked to children's exposures to water-damaged homes. Therefore, understanding the microbiome in water-damaged homes is critical to preventing these illnesses. Few studies have quantified bacterial contamination, especially specific species, in water-damaged homes. We collected air and dust samples in twenty-one low-mold homes and twenty-one high-mold homes. The concentrations of three bacteria/genera, Stenotrophomonas maltophilia, Streptomyces sp., and Mycobacterium sp., were measured in air and dust samples using quantitative PCR (QPCR). The concentrations of the bacteria measured in the air samples were not associated with any specific home characteristic based on multiple regression models. However, higher concentrations of S. maltophilia in the dust samples were associated with water damage, that is, with higher floor surface moisture and higher concentrations of moisture-related mold species. The concentrations of Streptomyces and Mycobacterium sp. had similar patterns and may be partially determined by human and animal occupants and outdoor sources of these bacteria. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. NIR spectroscopy as a tool for discriminating between lichens exposed to air pollution.

    PubMed

    Casale, Monica; Bagnasco, Lucia; Giordani, Paolo; Mariotti, Mauro Giorgio; Malaspina, Paola

    2015-09-01

    Lichens are used as biomonitors of air pollution because they are extremely sensitive to the presence of substances that alter atmospheric composition. Fifty-one thalli of two different varieties of Pseudevernia furfuracea (var. furfuracea and var. ceratea) were collected far from local sources of air pollution. Twenty-six of these thalli were then exposed to the air for one month in the industrial port of Genoa, which has high levels of environmental pollution. The possibility of using Near-infrared spectroscopy (NIRS) for generating a 'fingerprint' of lichens was investigated. Chemometric methods were successfully applied to discriminate between samples from polluted and non-polluted areas. In particular, Principal Component Analysis (PCA) was applied as a multivariate display method on the NIR spectra to visualise the data structure. This showed that the difference between samples of different varieties was not significant in comparison to the difference between samples exposed to different levels of environmental pollution. Then Linear Discriminant Analysis (LDA) was carried out to discriminate between lichens based on their exposure to pollutants. The distinction between control samples (not exposed) and samples exposed to the air in the industrial port of Genoa was evaluated. On average, 95.2% of samples were correctly classified, 93.0% of total internal prediction (5 cross-validation groups) and 100.0% of external prediction (on the test set) was achieved. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Organic composition of fogwater in the Texas-Louisiana gulf coast corridor

    NASA Astrophysics Data System (ADS)

    Raja, Suresh; Raghunathan, Ravikrishna; Kommalapati, Raghava R.; Shen, Xinhua; Collett, Jeffrey L.; Valsaraj, Kalliat T.

    Fogwater and air samples were collected in Baton Rouge between November 2004-February 2005 and during February 2006 at Houston. Organic compounds present in the fog samples were detected, quantified and then grouped into different compound classes based on molecular size, solubility and polarity using gas chromatography/mass spectrometry, high performance liquid chromatography with diode array detection and ion chromatography. Organic compounds were grouped as n-alkanes, aromatics and polycyclic aromatics, carbonyls, alcohols, amides and esters. Organic compounds in fog and air samples in Houston indicated clear urban/industrial anthropogenic origin, while compounds detected in Baton Rouge fog and air samples showed a mix of both agricultural and urban/industrial anthropogenic inputs. Among the various polycyclic aromatic compounds detected, the total concentration of naphthalene and its derivatives was 2.8 μg m -3 in Houston and 0.08 μg m -3 in Baton Rouge air. Analysis of concentrations of organic compounds pre- and post- fog revealed that compounds with low vapor pressure had higher scavenging efficiency in fog sampled at the two locations. Concentrations of organic compounds in fog samples were higher than those predicted by conventional air-water Henry's law equilibrium. Observed higher concentrations in the aqueous phase were modeled accounting for surface adsorption and accumulation of gas phase species and the presence of humic-like substances in fogwater.

  2. Evaluation of sampling methods for measuring exposure to volatile inorganic acids in workplace air. Part 1: sampling hydrochloric acid (HCl) and nitric acid (HNO₃) from a test gas atmosphere.

    PubMed

    Howe, Alan; Musgrove, Darren; Breuer, Dietmar; Gusbeth, Krista; Moritz, Andreas; Demange, Martine; Oury, Véronique; Rousset, Davy; Dorotte, Michel

    2011-08-01

    Historically, workplace exposure to the volatile inorganic acids hydrochloric acid (HCl) and nitric acid (HNO(3)) has been determined mostly by collection on silica gel sorbent tubes and analysis of the corresponding anions by ion chromatography (IC). However, HCl and HNO(3) can be present in workplace air in the form of mist as well as vapor, so it is important to sample the inhalable fraction of airborne particles. As sorbent tubes exhibit a low sampling efficiency for inhalable particles, a more suitable method was required. This is the first of two articles on "Evaluation of Sampling Methods for Measuring Exposure to Volatile Inorganic Acids in Workplace Air" and describes collaborative sampling exercises carried out to evaluate an alternative method for sampling HCl and HNO(3) using sodium carbonate-impregnated filters. The second article describes sampling capacity and breakthrough tests. The method was found to perform well and a quartz fiber filter impregnated with 500 μL of 1 M Na(2)CO(3) (10% (m/v) Na(2)CO(3)) was found to have sufficient sampling capacity for use in workplace air measurement. A pre-filter is required to remove particulate chlorides and nitrates that when present would otherwise result in a positive interference. A GSP sampler fitted with a plastic cone, a closed face cassette, or a plastic IOM sampler were all found to be suitable for mounting the pre-filter and sampling filter(s), but care has to be taken with the IOM sampler to ensure that the sampler is tightly closed to avoid leaks. HCl and HNO(3) can react with co-sampled particulate matter on the pre-filter, e.g., zinc oxide, leading to low results, and stronger acids can react with particulate chlorides and nitrates removed by the pre-filter to liberate HCl and HNO(3), which are subsequently collected on the sampling filter, leading to high results. However, although there is this potential for both positive and negative interferences in the measurement, these are unavoidable. The method studied has now been published in ISO 21438-2:2009.

  3. Decreasing carbon monoxide in the diving air of artisanal fishermen in the Yucatán peninsula by separation of engine exhaust from compressor intake.

    PubMed

    Chin, Walter; Huchim-Lara, Oswaldo; Salas, Silvia

    2016-01-01

    Artisanal fishermen in the Yucatán Peninsula utilize hookah dive systems (HDS). The air compressors in these HDS are not filtered, and the intake is near the engine exhaust. This proximity allows carbon monoxide (CO) from the exhaust to directly enter the HDS volume tank and contaminate the fishermen diver's air supply. Conservative safety standards permit a diver's air supply to contain 10 parts per million (ppm) of CO. This study quantified the levels of CO in the diver's air supply both before and after physical separation of the engine exhaust from the compressor intake. CO levels in seven volume tanks were analyzed before and after a 1-inch hose was attached to the compressor intake and elevated 5 feet above the engine exhaust. The tanks were drained and refilled before collecting each set of pre- and post-intervention gas samples. Four CO measurements were collected before and after the intervention from each volume tank. A C-Squared© CO Analyzer (± 1 ppm), calibrated with a Praxair 70 ppm CON2 gas (± 5%), was used to analyze the gas samples. A paired samples t-test shows a statistically significant difference in average CO values before and after the intervention (t = 6.8674, df: 27; p⟨0.0001). The physical separation of the engine exhaust from the compressor intake reduced the CO contamination of the diver air supply by 72%. This intervention could be applied to the hookah systems in the rest of the fishing cooperative to reduce the divers' risk of CO poisoning. Copyright© Undersea and Hyperbaric Medical Society.

  4. Hydrogeologic and water-quality data from well clusters near the wastewater-treatment plant, U.S. Marine Corps Air Station, Cherry Point, North Carolina

    USGS Publications Warehouse

    Murray, L.C.; Daniel, C. C.

    1990-01-01

    Hydrogeologic and ground-water quality data were collected near the wastewater-treatment plant and associated polishing lagoons at the Marine Corps Air Station, Cherry Point, North Carolina, in 1988. Between March and May 1988, two observation wells were installed upgradient and six wells were installed downgradient of the polishing lagoons and sampled for organic and inorganic U.S. Environmental Protection Agency priority pollutants. Placement of the well screens allowed sampling from both the upper and lower parts of the surficial aquifer. Natural gamma-ray geophysical logs were run in the four deepest wells. Lithologic logs were prepared from split-spoon samples collected during the drilling operations. Laboratory hydraulic conductivity tests were conducted on samples of fine-grained material recovered from the two confining units that separate the surficial aquifer and the drinking-water supply aquifer; values ranged from 0.011 to 0.014 foot per day (4x10-6 to 5x10-6 centimeters per second). Static water levels were recorded on April 25, 1988. Relatively low concentrations of purgeable organic compounds (up to 2.2 micrograms per liter for dichlorodifluoromethane), acid and base/neutral extractable compounds (up to 58 micrograms per liter for bis(2-ethylhexyl) phthalate), or pesticides (up to 0.03 micrograms per liter for diazinon and methyl parathion) were detected in water samples collected from all of the wells. Trace metals were detected in concentrations above minimum detectable limits in all of the wells and were found to be higher in water samples collected from the downgradient wells (up to 320 micrograms per liter for zinc) than in water samples from the upgradient wells.

  5. Low concentrations of persistent organic pollutants (POPs) in air at Cape Verde.

    PubMed

    Nøst, Therese Haugdahl; Halse, Anne Karine; Schlabach, Martin; Bäcklund, Are; Eckhardt, Sabine; Breivik, Knut

    2018-01-15

    Ambient air is a core medium for monitoring of persistent organic pollutants (POPs) under the Stockholm Convention and is used in studies of global transports of POPs and their atmospheric sources and source regions. Still, data based on active air sampling remain scarce in many regions. The primary objectives of this study were to (i) monitor concentrations of selected POPs in air outside West Africa, and (ii) to evaluate potential atmospheric processes and source regions affecting measured concentrations. For this purpose, an active high-volume air sampler was installed on the Cape Verde Atmospheric Observatory at Cape Verde outside the coast of West Africa. Sampling commenced in May 2012 and 43 samples (24h sampling) were collected until June 2013. The samples were analyzed for selected polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), hexachlorobenzene (HCB) and chlordanes. The concentrations of these POPs at Cape Verde were generally low and comparable to remote sites in the Arctic for several compounds. Seasonal trends varied between compounds and concentrations exhibited strong temperature dependence for chlordanes. Our results indicate net volatilization from the Atlantic Ocean north of Cape Verde as sources of these POPs. Air mass back trajectories demonstrated that air masses measured at Cape Verde were generally transported from the Atlantic Ocean or the North African continent. Overall, the low concentrations in air at Cape Verde were likely explained by absence of major emissions in areas from which the air masses originated combined with depletion during long-range atmospheric transport due to enhanced degradation under tropical conditions (high temperatures and concentrations of hydroxyl radicals). Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  6. Tritium and radioactive carbon (14C) analyses of gas collected from unsaturated sediments next to a low-level radioactive-waste burial site south of Beatty, Nevada, April 1994 and July 1995

    USGS Publications Warehouse

    Prudic, David E.; Striegl, Robert G.

    1995-01-01

    Tritium activities in water vapor and radioactive carbon (14C) activities in carbon dioxide were determined in gas samples pumped from small-diameter air ports installed in a test hole within the unsaturated sediments next to a commercial burial site for low-level radioactive waste south of Beatty, Nevada. In April 1994, gas samples were collected from test hole UZB-2, which was drilled about 350 feet south of the southwest corner of the fence enclosing the burial site. The test hole is part of a study to determine the depth to which atmospheric air circulates through the unsaturated sediments at the desert site. Laboratory results completed in May 1995 show activities of tritium and 14C were greater than expected, with measured tritium in the water vapor as high as 762 tritium units at a depth of 79 feet and measured 14C in carbon dioxide as high as 1,700 percent modern carbon at a depth of 18 feet.In July 1995, the uppermost five air ports in test hole UZB-2 were resampled. In addition, water vapor was collected for tritium analyses at a distant test hole, and water vapor for tritium analyses and carbon dioxide for 14C analyses were collected from three depths at the research shaft about 200 feet north of test hole UZB-2, and at two shallow probes (depth of 5.5 feet) next to the fence enclosing the burial site. Analyses of samples collected in the upper 112 feet from test hole UZB-2 in July 1995 show the same distribution of tritium and 14C as analyses of samples collected in April 1994, except that activities were somewhat greater in July. The greatest activities of tritium and 14C were measured from a shallow probe next to the fence with activities of 29,400 tritium units and 517,000 percent modern carbon, respectively.

  7. Installation Restoration Program. Phase 2. Confirmation/Quantification. Stage 1. Air Force Plant 38, Porter, New York

    DTIC Science & Technology

    1988-04-01

    drainageways collect surface runoff at the plant and channel the water off plant property. These are: the Central Drain- age Ditch, the Magazine Ditch, and...past, this drain- age system collected test area deluge waters , small spills from test- ing areas, and drainage from around the flush and maintenance...Drain- age Ditch Table 4-2 shows the results of the analyses of two water samples and one soil/sediment sample that were obtained from the drainage from

  8. Simultaneous sampling of indoor and outdoor airborne radioactivity after the Fukushima Daiichi nuclear power plant accident.

    PubMed

    Ishikawa, Tetsuo; Sorimachi, Atsuyuki; Arae, Hideki; Sahoo, Sarata Kumar; Janik, Miroslaw; Hosoda, Masahiro; Tokonami, Shinji

    2014-02-18

    Several studies have estimated inhalation doses for the public because of the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident. Most of them were based on measurement of radioactivity in outdoor air and included the assumption that people stayed outdoors all day. Although this assumption gives a conservative estimate, it is not realistic. The "air decontamination factor" (ratio of indoor to outdoor air radionuclide concentrations) was estimated from simultaneous sampling of radioactivity in both inside and outside air of one building. The building was a workplace and located at the National Institute of Radiological Sciences (NIRS) in Chiba Prefecture, Japan. Aerosol-associated radioactive materials in air were collected onto filters, and the filters were analyzed by γ spectrometry at NIRS. The filter sampling was started on March 15, 2011 and was continued for more than 1 year. Several radionuclides, such as (131)I, (134)Cs, and (137)Cs were found by measuring the filters with a germanium detector. The air decontamination factor was around 0.64 for particulate (131)I and 0.58 for (137)Cs. These values could give implications for the ratio of indoor to outdoor radionuclide concentrations after the FDNPP accident for a similar type of building.

  9. Ambient air concentrations of PCDDs, PCDFs, coplanar PCBs, and PAHs at the Mississippi Sandhill Crane National Wildlife Refuge, Jackson County, Mississippi

    USGS Publications Warehouse

    White, D.H.; Hardy, J.W.

    1994-01-01

    Our objective was to determine the levels of selected airborne contaminants in ambient air at the Mississippi Sandhill Crane National Wildlife Refuge, Mississippi, that might be affecting the health of endangered cranes living there. Two high-volume air samplers were operated at separate locations on the Refuge during May?September 1991. The sampling media were micro-quartz filters in combination with polyurethane foam plugs. Composite bimonthly samples from each station were analyzed for polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), coplanar polychlorinated biphenyls (PCBs), and polycyclic aromatic hydrocarbons (PAHs). Overall, residue concentrations were low. The toxic PCDD isomer 2,3,7,8-tetra-CDD was not detected, nor was penta-CDD. There was no difference (P>0.05) in residue concentrations between stations or over time and meteorological parameters were not correlated with residue concentrations. Because contaminant levels and patterns may differ seasonally, we recommend that air samples collected during winter months also be analyzed for these same chemical groups.

  10. Anaerobic bacteria in wastewater treatment plant.

    PubMed

    Cyprowski, Marcin; Stobnicka-Kupiec, Agata; Ławniczek-Wałczyk, Anna; Bakal-Kijek, Aleksandra; Gołofit-Szymczak, Małgorzata; Górny, Rafał L

    2018-03-28

    The objective of this study was to assess exposure to anaerobic bacteria released into air from sewage and sludge at workplaces from a wastewater treatment plant (WWTP). Samples of both sewage and sludge were collected at six sampling points and bioaerosol samples were additionally collected (with the use of a 6-stage Andersen impactor) at ten workplaces covering different stages of the technological process. Qualitative identification of all isolated strains was performed using the biochemical API 20A test. Additionally, the determination of Clostridium pathogens was carried out using 16S rRNA gene sequence analysis. The average concentration of anaerobic bacteria in the sewage samples was 5.49 × 10 4 CFU/mL (GSD = 85.4) and in sludge-1.42 × 10 6 CFU/g (GSD = 5.1). In turn, the average airborne bacterial concentration was at the level of 50 CFU/m 3 (GSD = 5.83) and the highest bacterial contamination (4.06 × 10 3  CFU/m 3 ) was found in winter at the bar screens. In total, 16 bacterial species were determined, from which the predominant strains belonged to Actinomyces, Bifidobacterium, Clostridium, Propionibacterium and Peptostreptococcus genera. The analysis revealed that mechanical treatment processes were responsible for a substantial emission of anaerobic bacteria into the air. In both the sewage and air samples, Clostridium perfringens pathogen was identified. Anaerobic bacteria were widely present both in the sewage and in the air at workplaces from the WWTP, especially when the technological process was performed in closed spaces. Anaerobic bacteria formed small aggregates with both wastewater droplets and dust particles of sewage sludge origin and as such may be responsible for adverse health outcomes in exposed workers.

  11. Volatile Organic Compounds (VOCs) Measurements in Karachi, Pakistan (2006): a Comparison With Previous Urban Sampling Campaigns Worldwide.

    NASA Astrophysics Data System (ADS)

    Barletta, B.; Meinardi, S.; Khwaja, H. A.; Beyersdorf, A. J.; Baker, A. K.; Zou, S.; Rowland, F.; Blake, D. R.

    2008-12-01

    Mixing ratios of carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), and 47 nonmethane hydrocarbons - NMHCs - (19 alkanes, 13 alkenes, ethyne, and 14 aromatics) were determined for ground level whole air samples collected during the winter of 2006 in Karachi, Pakistan. Pakistan is among the fastest growing economies in Asia, and Karachi is one of the largest cities in the world with a rapidly expanding population of over 14 million in the whole metropolitan area, and a large industrial base. Samples were collected in January 2006 throughout the urban area to characterize the overall air composition of the city, and along the busiest road to determine the traffic signature of Karachi. This sampling campaign follows a previous study carried out in the winter of 1998-1999 in the same city, when elevated concentrations of many NMHCs were observed. Exceptionally high levels of methane were still observed in 2006 with an average mixing ratio of 5.0 ppmv (6.3 ppmv were observed in 1999). The overall air composition of the Karachi urban environment characterized during this 2006 sampling is compared to 1999 aiming to highlight any possible change in the main VOC sources present throughout the city. In particular, we want to evaluate the impact of the heavy usage of natural gas on the overall air quality of Karachi and the recently increased use of liquefied petroleum gas (LPG) as alternative source of energy. We also compare the composition of the urban troposphere of Karachi to other major urban centers worldwide such as Guangzhou (China), Mexico City (Mexico), and Milan (Italy).

  12. Contamination source review for Building E5485, Edgewood Area, Aberdeen Proving Ground, Maryland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Billmark, K.A.; Hayes, D.C.; Draugelis, A.K.

    1995-09-01

    This report was prepared by Argonne National Laboratory (ANL) to document the results of a contamination source review of Building E5485 at the Aberdeen Proving Ground (APG) in Maryland. This report may be used to assist the US Army in planning for the future use or disposition of this building. The review included a historical records search, physical inspection, photographic documentation, geophysical investigation, and collection of air samples. Building E5485 (APG designation) is located in the drainage basin of the west branch of Canal Creek in the Edgewood Area of APG. The building was constructed in 1922 and used asmore » a fan house for agent operations in Building E5487 from 1925 to 1966. Building E5485 was then used as a laboratory to support manufacturing and storage of flammable agents and chemical warfare agents from 1966 until 1967, when it was placed on the inactive list. Air quality samples were collected upwind, downwind, and inside Building E5485 in November 1994. Analytical results showed no distinguishable difference in hydrocarbon and chlorinated solvent levels between the two background samples and the sample collected inside Building E5485. These results indicate that Building E5485 is not a source of volatile organic compound contamination.« less

  13. Analytical results from an environmental investigation of six sites on Kirtland Air Force Base, New Mexico, 1993-94

    USGS Publications Warehouse

    Wilcox, Ralph

    1995-01-01

    The six sites investigated include silver recovery units; a buried caustic drain line; a neutralization pit; an evaporation/infiltration pond; the Manzano fire training area; and a waste oil underground storage tank. Environmental samples of soil, pond sediment, soil gas, and water and gas in floor drains were collected and analyzed. Field quality-control samples were also collected and analyzed in association with the environmental samples. The six sites were investigated because past or current activities could have resulted in contamination of soil, pond sediment, or water and sediment in drains.

  14. A Comprehensive Assessment of Biologicals Contained Within Commercial Airliner Cabin Air

    NASA Technical Reports Server (NTRS)

    LaDuc, Myron T.; Osman, Shariff; Dekas, Anne; Stuecker, Tara; Newcombe, Dave; Piceno, Yvette; Fuhrman, J.; Andersen, Gary; Venkateswaran, Kasthuri; Bearman, Greg

    2006-01-01

    Both culture-based and culture-independent, biomarker-targeted microbial enumeration and identification technologies were employed to estimate total microbial and viral burden and diversity within the cabin air of commercial airliners. Samples from each of twenty flights spanning three commercial carriers were collected via air-impingement. When the total viable microbial population was estimated by assaying relative concentrations of the universal energy carrier ATP, values ranged from below detection limits (BDL) to 4.1 x 106 cells/cubic m of air. The total viable microbial population was extremely low in both of Airline A (approximately 10% samples) and C (approximately 18% samples) compared to the samples collected aboard flights on Airline A and B (approximately 70% samples). When samples were collected as a function of time over the course of flights, a gradual accumulation of microbes was observed from the time of passenger boarding through mid-flight, followed by a sharp decline in microbial abundance and viability from the initiation of descent through landing. It is concluded in this study that only 10% of the viable microbes of the cabin air were cultivable and suggested a need to employ state-of-the art molecular assay that measures both cultivable and viable-but-non-cultivable microbes. Among the cultivable bacteria, colonies of Acinetobacter sp. were by far the most profuse in Phase I, and Gram-positive bacteria of the genera Staphylococcus and Bacillus were the most abundant during Phase II. The isolation of the human pathogens Acinetobacter johnsonii, A. calcoaceticus, Janibacter melonis, Microbacterium trichotecenolyticum, Massilia timonae, Staphylococcus saprophyticus, Corynebacterium lipophiloflavum is concerning, as these bacteria can cause meningitis, septicemia, and a handful of sometimes fatal diseases and infections. Molecular microbial community analyses exhibited presence of the alpha-, beta-, gamma-, and delta- proteobacteria, as well as Gram-positive bacteria, Fusobacteria, Cyanobacteria, Deinococci, Bacterioidetes, Spirochetes, and Planctomyces in varying abundance. Neisseria meningitidis rDNA sequences were retrieved in great abundance from Airline A followed by Streptococcus oralis/mitis sequences. Pseudomonas synxantha sequences dominated Airline B clone libraries, followed by those of N. meningitidis and S. oralis/mitis. In Phase II, Airline C, sequences representative of more than 113 species, enveloping 12 classes of bacteria, were retrieved. Proteobacterial sequences were retrieved in greatest frequency (58% of all clone sequences), followed in short order by those stemming from Gram-positives bacteria (31% of all clone sequences). As for overall phylogenetic breadth, Gram-positive and alpha-proteobacteria seem to have a higher affinity for international flights, whereas beta-and gamma-proteobacteria are far more common about domestic cabin air parcels in Airline C samples. Ultimately, the majority of microbial species circulating throughout the cabin airs of commercial airliners are commensal, infrequently pathogenic normal flora of the human nasopharynx and respiratory system. Many of these microbes likely originate from the oral and nasal cavities, and lungs of passengers and flight crew and are disseminated unknowingly via routine conversation, coughing, sneezing, and stochastic passing of fomites. The data documented in this study will be useful to generate a baseline microbial population database and can be utilized to develop biosensor instrumentation for monitoring microbial quality of cabin or urban air.

  15. Urinary polycyclic aromatic hydrocarbons as a biomarker of exposure to PAHs in air: a pilot study among pregnant women.

    PubMed

    Nethery, Elizabeth; Wheeler, Amanda J; Fisher, Mandy; Sjödin, Andreas; Li, Zheng; Romanoff, Lovisa C; Foster, Warren; Arbuckle, Tye E

    2012-01-01

    Recent studies have linked increased polycyclic aromatic hydrocarbons (PAHs) in air and adverse fetal health outcomes. Urinary PAH metabolites are of interest for exposure assessment if they can predict PAHs in air. We investigated exposure to PAHs by collecting air and urine samples among pregnant women pre-selected as living in "high" (downtown and close to steel mills, n=9) and "low" (suburban, n=10) exposure areas. We analyzed first-morning urine voids from all 3 trimesters of pregnancy for urinary PAH metabolites and compared these to personal air PAH/PM(2.5)/NO(2)/NO(X) samples collected in the 3rd trimester. We also evaluated activities and home characteristics, geographic indicators and outdoor central site PM(2.5)/NO(2)/NO(X) (all trimesters). Personal air exposures to the lighter molecular weight (MW) PAHs were linked to indoor sources (candles and incense), whereas the heavier PAHs were related to outdoor sources. Geometric means of all personal air measurements were higher in the "high" exposure group. We suggest that centrally monitored heavier MW PAHs could be used to predict personal exposures for heavier PAHs only. Urine metabolites were only directly correlated with their parent air PAHs for phenanthrene (Pearson's r=0.31-0.45) and fluorene (r=0.37-0.58). Predictive models suggest that specific metabolites (3-hydroyxyfluorene and 3-hydroxyphenanthrene) may be related to their parent air PAH exposures. The metabolite 2-hydroxynaphthalene was linked to smoking and the metabolite 1-hydroxypyrene was linked to dietary exposures. For researchers interested in predicting exposure to airborne lighter MW PAHs using urinary PAH metabolites, we propose that hydroxyfluorene and hydroxyphenanthrene metabolites be considered.

  16. Evaluation of ELISA screening test for detecting aflatoxin in biogenic dust samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durant, J.T.

    Aflatoxin is a carcinogenic chemical that is sometimes produced when agricultural commodities are infested by the fungi Aspergillus flavus and A. Parasiticus. Aflatoxin has been found to be present in air samples taken around persons handling materials likely to be contaminated. The purpose of this investigation was to demonstrate the feasibility of using an Enzyme Linked Immunosorbent Assay (ELISA) test kit that was developed to screen for aflatoxin in bulk agricultural commodities, to an air sample. Samples were taken from two environments likely to be contaminated with aflatoxin, a dairy farm feed mixing operation and a peanut bagging operation. Themore » dust collected from these environments was considered to be biogenic, in that it originated primarily from biological materials.« less

  17. Elemental properties of coal slag and measured airborne exposures at two coal slag processing facilities

    PubMed Central

    Mugford, Christopher; Boylstein, Randy; Gibbs, Jenna L

    2017-01-01

    In 1974, the National Institute for Occupational Safety and Health recommended a ban on the use of silica sand abrasives containing >1% silica due to the risk of silicosis. This gave rise to substitutes including coal slag. An Occupational Safety and Health Administration investigation in 2010 uncovered a case cluster of suspected pneumoconiosis in four former workers at a coal slag processing facility in Illinois, possibly attributable to occupational exposure to coal slag dust. This article presents the results from a National Institute for Occupational Safety and Health industrial hygiene survey at the same coal slag processing facility and a second facility. The industrial hygiene survey consisted of the collection of: a) bulk samples of unprocessed coal slag, finished granule product, and settled dust for metals and silica; b) full-shift area air samples for dust, metals, and crystalline silica; and c) full-shift personal air samples for dust, metals, and crystalline silica. Bulk samples consisted mainly of iron, manganese, titanium, and vanadium. Some samples had detectable levels of arsenic, beryllium, cadmium, and cobalt. Unprocessed coal slags from Illinois and Kentucky contained 0.43–0.48% (4,300–4,800 mg/kg) silica. Full-shift area air samples identified elevated total dust levels in the screen (2–38 mg/m3) and bag house (21 mg/m3) areas. Full-shift area air samples identified beryllium, chromium, cobalt, copper, iron, nickel, manganese, and vanadium. Overall, personal air samples for total and respirable dust (0.1–6.6 mg/m3 total; and 0.1–0.4 mg/m3 respirable) were lower than area air samples. All full-shift personal air samples for metals and silica were below published occupational exposure limits. All bulk samples of finished product granules contained less than 1% silica, supporting the claim coal slag may present less risk for silicosis than silica sand. We note that the results presented here are solely from two coal slag processing facilities, and more in-depth air monitoring is needed to better characterize occupational exposure to coal slag dust, metals, and silica at similar facilities. PMID:27808662

  18. Elemental properties of coal slag and measured airborne exposures at two coal slag processing facilities.

    PubMed

    Mugford, Christopher; Boylstein, Randy; Gibbs, Jenna L

    2017-05-01

    In 1974, the National Institute for Occupational Safety and Health recommended a ban on the use of silica sand abrasives containing >1% silica due to the risk of silicosis. This gave rise to substitutes including coal slag. An Occupational Safety and Health Administration investigation in 2010 uncovered a case cluster of suspected pneumoconiosis in four former workers at a coal slag processing facility in Illinois, possibly attributable to occupational exposure to coal slag dust. This article presents the results from a National Institute for Occupational Safety and Health industrial hygiene survey at the same coal slag processing facility and a second facility. The industrial hygiene survey consisted of the collection of: (a) bulk samples of unprocessed coal slag, finished granule product, and settled dust for metals and silica; (b) full-shift area air samples for dust, metals, and crystalline silica; and (c) full-shift personal air samples for dust, metals, and crystalline silica. Bulk samples consisted mainly of iron, manganese, titanium, and vanadium. Some samples had detectable levels of arsenic, beryllium, cadmium, and cobalt. Unprocessed coal slags from Illinois and Kentucky contained 0.43-0.48% (4,300-4,800 mg/kg) silica. Full-shift area air samples identified elevated total dust levels in the screen (2-38 mg/m 3 ) and bag house (21 mg/m 3 ) areas. Full-shift area air samples identified beryllium, chromium, cobalt, copper, iron, nickel, manganese, and vanadium. Overall, personal air samples for total and respirable dust (0.1-6.6 mg/m 3 total; and 0.1-0.4 mg/m 3 respirable) were lower than area air samples. All full-shift personal air samples for metals and silica were below published occupational exposure limits. All bulk samples of finished product granules contained less than 1% silica, supporting the claim coal slag may present less risk for silicosis than silica sand. We note that the results presented here are solely from two coal slag processing facilities, and more in-depth air monitoring is needed to better characterize occupational exposure to coal slag dust, metals, and silica at similar facilities.

  19. Development, evaluation and comparison of two independent sampling and analytical methods for ortho-phthalaldehyde vapors and condensation aerosols in air† ‡

    PubMed Central

    2015-01-01

    Two independent sampling and analytical methods for ortho-phthalaldehyde (OPA) in air have been developed, evaluated and compared (1) a reagent-coated solid sorbent HPLC-UV method and (2) an impinger-fluorescence method. In the first method, air sampling is conducted at 1.0 L min−1 with a sampler containing 350 mg of silica gel coated with 1 mg of acidified 2,4-dinitrophenylhydrazine (DNPH). After sampling, excess DNPH in ethyl acetate is added to the sampler prior to storage for 68 hours. The OPA-DNPH derivative is eluted with 4.0 mL of dimethyl sulfoxide (DMSO) for measurement by HPLC with a UV detector set at 3S5 nm. The estimated detection limit is 0.016 µg per sample or 0.067 µg m−3 (0.012 ppb) for a 240 L air sample. Recoveries of vapor spikes at levels of 1.2 to 6.2 µg were 96 to 101%. Recoveries of spikes as mixtures of vapor and condensation aerosols were 97 to 100%. In the second method, air sampling is conducted at 1.0 L mm−1 with a midget impinger containing 10 mL of DMSO solution containing N-acetyl-l-cysteine and ethylenediamine. The fluorescence reading is taken 80 min after the completion of air sampling. Since the time of taking the fluorescence reading is critical, the reading is taken with a portable fluorometer. The estimated detection limit is 0.024 µg per sample or 0.1 µg m−3 (0.018 ppb) for a 240 L air sample. Recoveries of OPA vapor spikes at levels of 1.4 to 5.0 µg per sample were 97 to 105%. Recoveries of spikes as mixtures of vapors and condensation aerosols were 95 to 99%. The collection efficiency for a mixture of vapor and condensation aerosol was 99.4%. The two methods were compared side-by-side in a generation system constructed for producing controlled atmospheres of OPA vapor in air. Average air concentrations of OPA vapor found by both methods agreed within ±10%. PMID:26346658

  20. Immunological techniques as tools to characterize the subsurface microbial community at a trichloroethylene contaminated site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fliermans, C.B.; Dougherty, J.M.; Franck, M.M.

    Effective in situ bioremediation strategies require an understanding of the effects pollutants and remediation techniques have on subsurface microbial communities. Therefore, detailed characterization of a site`s microbial communities is important. Subsurface sediment borings and water samples were collected from a trichloroethylene (TCE) contaminated site, before and after horizontal well in situ air stripping and bioventing, as well as during methane injection for stimulation of methane-utilizing microorganisms. Subsamples were processed for heterotrophic plate counts, acridine orange direct counts (AODC), community diversity, direct fluorescent antibodies (DFA) enumeration for several nitrogen-transforming bacteria, and Biolog {reg_sign} evaluation of enzyme activity in collected water samples.more » Plate counts were higher in near-surface depths than in the vadose zone sediment samples. During the in situ air stripping and bioventing, counts increased at or near the saturated zone, remained elevated throughout the aquifer, but did not change significantly after the air stripping. Sporadic increases in plate counts at different depths as well as increased diversity appeared to be linked to differing lithologies. AODCs were orders of magnitude higher than plate counts and remained relatively constant with depth except for slight increases near the surface depths and the capillary fringe. Nitrogen-transforming bacteria, as measured by serospecific DFA, were greatly affected both by the in situ air stripping and the methane injection. Biolog{reg_sign} activity appeared to increase with subsurface stimulation both by air and methane. The complexity of subsurface systems makes the use of selective monitoring tools imperative.« less

  1. Phytoforensics: Trees as bioindicators of potential indoor exposure via vapor intrusion.

    PubMed

    Wilson, Jordan L; Samaranayake, V A; Limmer, Matt A; Burken, Joel G

    2018-01-01

    Human exposure to volatile organic compounds (VOCs) via vapor intrusion (VI) is an emerging public health concern with notable detrimental impacts on public health. Phytoforensics, plant sampling to semi-quantitatively delineate subsurface contamination, provides a potential non-invasive screening approach to detect VI potential, and plant sampling is effective and also time- and cost-efficient. Existing VI assessment methods are time- and resource-intensive, invasive, and require access into residential and commercial buildings to drill holes through basement slabs to install sampling ports or require substantial equipment to install groundwater or soil vapor sampling outside the home. Tree-core samples collected in 2 days at the PCE Southeast Contamination Site in York, Nebraska were analyzed for tetrachloroethene (PCE) and results demonstrated positive correlations with groundwater, soil, soil-gas, sub-slab, and indoor-air samples collected over a 2-year period. Because tree-core samples were not collocated with other samples, interpolated surfaces of PCE concentrations were estimated so that comparisons could be made between pairs of data. Results indicate moderate to high correlation with average indoor-air and sub-slab PCE concentrations over long periods of time (months to years) to an interpolated tree-core PCE concentration surface, with Spearman's correlation coefficients (ρ) ranging from 0.31 to 0.53 that are comparable to the pairwise correlation between sub-slab and indoor-air PCE concentrations (ρ = 0.55, n = 89). Strong correlations between soil-gas, sub-slab, and indoor-air PCE concentrations and an interpolated tree-core PCE concentration surface indicate that trees are valid indicators of potential VI and human exposure to subsurface environment pollutants. The rapid and non-invasive nature of tree sampling are notable advantages: even with less than 60 trees in the vicinity of the source area, roughly 12 hours of tree-core sampling with minimal equipment at the PCE Southeast Contamination Site was sufficient to delineate vapor intrusion potential in the study area and offered comparable delineation to traditional sub-slab sampling performed at 140 properties over a period of approximately 2 years.

  2. Phytoforensics: Trees as bioindicators of potential indoor exposure via vapor intrusion

    USGS Publications Warehouse

    Wilson, Jordan L.; Samaranayake, V.A.; Limmer, Matthew A.; Burken, Joel G.

    2018-01-01

    Human exposure to volatile organic compounds (VOCs) via vapor intrusion (VI) is an emerging public health concern with notable detrimental impacts on public health. Phytoforensics, plant sampling to semi-quantitatively delineate subsurface contamination, provides a potential non-invasive screening approach to detect VI potential, and plant sampling is effective and also time- and cost-efficient. Existing VI assessment methods are time- and resource-intensive, invasive, and require access into residential and commercial buildings to drill holes through basement slabs to install sampling ports or require substantial equipment to install groundwater or soil vapor sampling outside the home. Tree-core samples collected in 2 days at the PCE Southeast Contamination Site in York, Nebraska were analyzed for tetrachloroethene (PCE) and results demonstrated positive correlations with groundwater, soil, soil-gas, sub-slab, and indoor-air samples collected over a 2-year period. Because tree-core samples were not collocated with other samples, interpolated surfaces of PCE concentrations were estimated so that comparisons could be made between pairs of data. Results indicate moderate to high correlation with average indoor-air and sub-slab PCE concentrations over long periods of time (months to years) to an interpolated tree-core PCE concentration surface, with Spearman’s correlation coefficients (ρ) ranging from 0.31 to 0.53 that are comparable to the pairwise correlation between sub-slab and indoor-air PCE concentrations (ρ = 0.55, n = 89). Strong correlations between soil-gas, sub-slab, and indoor-air PCE concentrations and an interpolated tree-core PCE concentration surface indicate that trees are valid indicators of potential VI and human exposure to subsurface environment pollutants. The rapid and non-invasive nature of tree sampling are notable advantages: even with less than 60 trees in the vicinity of the source area, roughly 12 hours of tree-core sampling with minimal equipment at the PCE Southeast Contamination Site was sufficient to delineate vapor intrusion potential in the study area and offered comparable delineation to traditional sub-slab sampling performed at 140 properties over a period of approximately 2 years.

  3. Phytoforensics: Trees as bioindicators of potential indoor exposure via vapor intrusion

    PubMed Central

    2018-01-01

    Human exposure to volatile organic compounds (VOCs) via vapor intrusion (VI) is an emerging public health concern with notable detrimental impacts on public health. Phytoforensics, plant sampling to semi-quantitatively delineate subsurface contamination, provides a potential non-invasive screening approach to detect VI potential, and plant sampling is effective and also time- and cost-efficient. Existing VI assessment methods are time- and resource-intensive, invasive, and require access into residential and commercial buildings to drill holes through basement slabs to install sampling ports or require substantial equipment to install groundwater or soil vapor sampling outside the home. Tree-core samples collected in 2 days at the PCE Southeast Contamination Site in York, Nebraska were analyzed for tetrachloroethene (PCE) and results demonstrated positive correlations with groundwater, soil, soil-gas, sub-slab, and indoor-air samples collected over a 2-year period. Because tree-core samples were not collocated with other samples, interpolated surfaces of PCE concentrations were estimated so that comparisons could be made between pairs of data. Results indicate moderate to high correlation with average indoor-air and sub-slab PCE concentrations over long periods of time (months to years) to an interpolated tree-core PCE concentration surface, with Spearman’s correlation coefficients (ρ) ranging from 0.31 to 0.53 that are comparable to the pairwise correlation between sub-slab and indoor-air PCE concentrations (ρ = 0.55, n = 89). Strong correlations between soil-gas, sub-slab, and indoor-air PCE concentrations and an interpolated tree-core PCE concentration surface indicate that trees are valid indicators of potential VI and human exposure to subsurface environment pollutants. The rapid and non-invasive nature of tree sampling are notable advantages: even with less than 60 trees in the vicinity of the source area, roughly 12 hours of tree-core sampling with minimal equipment at the PCE Southeast Contamination Site was sufficient to delineate vapor intrusion potential in the study area and offered comparable delineation to traditional sub-slab sampling performed at 140 properties over a period of approximately 2 years. PMID:29451904

  4. Indoor air quality in urban and rural kindergartens: short-term studies in Silesia, Poland.

    PubMed

    Błaszczyk, Ewa; Rogula-Kozłowska, Wioletta; Klejnowski, Krzysztof; Kubiesa, Piotr; Fulara, Izabela; Mielżyńska-Švach, Danuta

    2017-01-01

    More than 80% of people living in urban areas who monitor air pollution are exposed to air quality levels that exceed limits defined by the World Health Organization (WHO). Although all regions of the world are affected, populations in low-income cities are the most impacted. According to average annual levels of fine particulate matter (PM2.5, ambient particles with aerodynamic diameter of 2.5 μm or less) presented in the urban air quality database issued by WHO in 2016, as many as 33 Polish cities are among the 50 most polluted cities in the European Union (EU), with Silesian cities topping the list. The aim of this study was to characterize the indoor air quality in Silesian kindergartens based on the concentrations of gaseous compounds (SO 2 , NO 2 ), PM2.5, and the sum of 15 PM2.5-bound polycyclic aromatic hydrocarbons (PAHs), including PM2.5-bound benzo(a)pyrene (BaP), as well as the mutagenic activity of PM2.5 organic extracts in Salmonella assay (strains: TA98, YG1024). The assessment of the indoor air quality was performed taking into consideration the pollution of the atmospheric air (outdoor). I/O ratios (indoor/outdoor concentration) for each investigated parameter were also calculated. Twenty-four-hour samples of PM2.5, SO 2 , and NO 2 were collected during spring in two sites in southern Poland (Silesia), representing urban and rural areas. Indoor samples were taken in naturally ventilated kindergartens. At the same time, in the vicinity of the kindergarten buildings, the collection of outdoor samples of PM2.5, SO 2 , and NO 2 was carried out. The content of BaP and the sum of 15 studied PAHs was determined in each 24-h sample of PM2.5 (indoor and outdoor). In the urban site, statistically lower concentrations of SO 2 and NO 2 were detected indoors compared to outdoors, whereas in the rural site, such a relationship was observed only for NO 2 . No statistically significant differences in the concentrations of PM2.5, PM2.5-bound BaP, and Σ15 PAHs in kindergartens (indoor) versus atmospheric (outdoor) air in the two studied areas were identified. Mutagenic effect of indoor PM2.5 samples was twice as low as in outdoor samples. The I/O ratios indicated that all studied air pollutants in the urban kindergarten originated from the ambient air. In the rural site concentrations of SO 2 , PM2.5 and BaP in the kindergarten were influenced by internal sources (gas and coal stoves).

  5. Unmetabolized VOCs in urine as biomarkers of low level occupational exposure.

    PubMed

    Janasik, Beata; Jakubowski, Marek; Wesołowski, Wiktor; Kucharska, Małgorzata

    2010-01-01

    To compare the usefulness of determining unchanged forms of volatile organic compounds (VOCs), namely toluene (TOL), ethylbenzene (EB) and xylene (XYL), in urine with the effectiveness of the already used biomarkers of occupational exposure. Surveys were conducted in two workplaces (paint factory and footwear factory). In total, 65 subjects participated in the study. Air samples were collected using individual samplers during work shift. Urine and blood samples were collected at the end of work shift. Urine samples were analyzed for unchanged compounds and selected metabolites, while blood samples were tested for unchanged compounds. VOCs in blood and urine were determined by solid phase microextraction gas chromatography (SPME-GC-MS). In the paint factory, the geometric mean (GM) concentrations of VOCs in the air ranged as follows: 0.2-4.7 mg/m(3) for TOL, 0.4-40.9 mg/m(3) for EB and 0.1-122.6 mg/m(3) for XYL. In the footwear factory, the GM concentration of TOL in the air amounted to 105.4 mg/m(3). A significant correlation (p < 0.05) was observed between VOCs in blood, urine and air. The regression analyses performed for paint factory workers showed that TOL-U and TOL-B were better biomarkers of exposure (r = 0.72 and r = 0.81) than benzoic acid (r = 0.12) or o-cresol (r = 0.55). The findings of the study point out that the concentration of unchanged VOCs in urine can be a reliable biological indicator of low level occupational exposure to these compounds.

  6. An analytical method for trifluoroacetic Acid in water and air samples using headspace gas chromatographic determination of the methyl ester.

    PubMed

    Zehavi, D; Seiber, J N

    1996-10-01

    An analytical method has been developed for the determination of trace levels of trifluoroacetic acid (TFA), an atmospheric breakdown product of several of the hydrofluorocarbon (HFC) and hydrochlorofluorocarbon (HCFC) replacements for the chlorofluorocarbon (CFC) refrigerants, in water and air. TFA is derivatized to the volatile methyl trifluoroacetate (MTFA) and determined by automated headspace gas chromatography (HSGC) with electron-capture detection or manual HSGC using GC/MS in the selected ion monitoring (SIM) mode. The method is based on the reaction of an aqueous sample containing TFA with dimethyl sulfate (DMS) in concentrated sulfuric acid in a sealed headspace vial under conditions favoring distribution of MTFA to the vapor phase. Water samples are prepared by evaporative concentration, during which TFA is retained as the anion, followed by extraction with diethyl ether of the acidified sample and then back-extraction of TFA (as the anion) in aqueous bicarbonate solution. The extraction step is required for samples with a relatively high background of other salts and organic materials. Air samples are collected in sodium bicarbonate-glycerin-coated glass denuder tubes and prepared by rinsing the denuder contents with water to form an aqueous sample for derivatization and analysis. Recoveries of TFA from spiked water, with and without evaporative concentration, and from spiked air were quantitative, with estimated detection limits of 10 ng/mL (unconcentrated) and 25 pg/mL (concentrated 250 mL:1 mL) for water and 1 ng/m(3) (72 h at 5 L/min) for air. Several environmental air, fogwater, rainwater, and surface water samples were successfully analyzed; many showed the presence of TFA.

  7. Ricketts Community Update No 3

    EPA Pesticide Factsheets

    In February 2017, the U.S. Environmental Protection Agency (EPA) collected air samples at 50 properties located near the Rickett’s Dry Cleaning facility located at 2017 Doubleday Avenue in the village of Ballston Spa.

  8. Environmental Radiation Data (ERD) Journal Report 161

    EPA Pesticide Factsheets

    RadNet environmental radiation monitoring data report for the period of January - March 2015. The report includes results for air, drinking water and precipitation samples collected as part of EPA's RadNet monitoring program.

  9. Environmental Radiation Data (ERD) Journal Report 157

    EPA Pesticide Factsheets

    RadNet environmental radiation monitoring data report for the period of January - March 2014. The report includes results for air, drinking water, precipitation samples collected as part of EPA's RadNet monitoring program.

  10. Environmental Radiation Data (ERD) Journal Report 162

    EPA Pesticide Factsheets

    RadNet environmental radiation monitoring data report for the period of April - June 2015. The report includes results for air, drinking water and precipitation samples collected as part of EPA's RadNet monitoring program.

  11. Environmental Radiation Data (ERD) Journal Report 155

    EPA Pesticide Factsheets

    RadNet environmental radiation monitoring data report for the period of July - September 2013. The report includes results for air, drinking water, precipitation samples collected as part of EPA's RadNet monitoring program.

  12. Environmental Radiation Data (ERD) Journal Report 154

    EPA Pesticide Factsheets

    RadNet environmental radiation monitoring data report for the period of April - June 2013. The report includes results for air, drinking water, precipitation samples collected as part of EPA's RadNet monitoring program.

  13. Environmental Radiation Data (ERD) Journal Report 158

    EPA Pesticide Factsheets

    RadNet environmental radiation monitoring data report for the period of April - June 2014. The report includes results for air, drinking water, precipitation samples collected as part of EPA's RadNet monitoring program.

  14. Environmental Radiation Data (ERD) Journal Report 163

    EPA Pesticide Factsheets

    RadNet environmental radiation monitoring data report for the period of July - September 2015. The report includes results for air, drinking water and precipitation samples collected as part of EPA's RadNet monitoring program.

  15. SMARTE'S SITE CHARACTERIZATION TOOL

    EPA Science Inventory

    Site Characterization involves collecting environmental data to evaluate the nature and extent of contamination. Environmental data could consist of chemical analyses of soil, sediment, water or air samples. Typically site characterization data are statistically evaluated for thr...

  16. Environmental Radiation Data (ERD) Journal Report 156

    EPA Pesticide Factsheets

    RadNet environmental radiation monitoring data report for the period of October - December 2013. The report includes results for air, drinking water, precipitation samples collected as part of EPA's RadNet monitoring program.

  17. Environmental Radiation Data (ERD) Journal Report 159

    EPA Pesticide Factsheets

    RadNet environmental radiation monitoring data report for the period of July - September 2014. The report includes results for air, drinking water and precipitation samples collected as part of EPA's RadNet monitoring program.

  18. Environmental Radiation Data (ERD) Journal Report 164

    EPA Pesticide Factsheets

    RadNet environmental radiation monitoring data report for the period of October - December 2015. The report includes results for air, drinking water and precipitation samples collected as part of EPA's RadNet monitoring program.

  19. Environmental Radiation Data (ERD) Journal Report 160

    EPA Pesticide Factsheets

    RadNet environmental radiation monitoring data report for the period of October - December 2014. The report includes results for air, drinking water and precipitation samples collected as part of EPA's RadNet monitoring program.

  20. Environmental Radiation Data (ERD) Journal Report 166

    EPA Pesticide Factsheets

    RadNet environmental radiation monitoring data report for the period of April - June 2016. The report includes results for air, drinking water and precipitation samples collected as part of EPA's RadNet monitoring program.

Top